WorldWideScience

Sample records for subway fire accident

  1. Smoke control of fires in subway stations

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Falin; Guo, Shin-Chang [Institute of Applied Mechanics, National Taiwan University, Taipei, Taiwan 106 (Taiwan); Chuay, He-Yuan [SinoTech Engineering Consulting Co., 171 Nanking E. Road, 5 Sec., Taipei, Taiwan 105 (Taiwan); Chien, Shen-Wen [Department of Fire Science and Administration, National Central Police University, Taoyuan, Taiwan 333 (Taiwan)

    2003-05-01

    We investigate the effectiveness of the smoke control scheme of the Gong-Guan subway station (GGSS), a typical subway station of the Taipei Rapid Transit System and whose mechanical control systems are also standard in modern subway station design. Three-dimensional smoke flow fields under various kinds of fires are computed by computational fluid dynamics techniques and the results are illustrated on various cross-sectional planes. Results indicate that the stack effect plays a deterministic role in smoke control when a fire occurs near the stairwell; under such circumstances, no mechanical smoke control is necessary. When a fire occurs in other places, such as at the end or the center of the platform, the current mechanical control schemes of GGSS are effective; namely, the smoke can be well controlled, either it is confined to a small region or is evacuated from the station, leaving the four exits free of smoke so that the passengers can escape through them. The effect of the platform edge door (PED) on smoke control is also investigated. With the PED, the effectiveness of the present smoke control system for fires occurring on the chassis of a train, a serious fire in the subway station, increases. We also propose an innovative smoke control scheme with a PED, which turns out to be much more efficient in evacuating smoke than that currently used. This study provides both valuable information for the design of passenger evacuation routes in fires as well as criteria for the design of a smoke control system for subway stations. (orig.)

  2. Pedestrian evacuation at the subway station under fire

    Science.gov (United States)

    Xiao-Xia, Yang; Hai-Rong, Dong; Xiu-Ming, Yao; Xu-Bin, Sun

    2016-04-01

    With the development of urban rail transit, ensuring the safe evacuation of pedestrians at subway stations has become an important issue in the case of an emergency such as a fire. This paper chooses the platform of line 4 at the Beijing Xuanwumen subway station to study the emergency evacuation process under fire. Based on the established platform, effects of the fire dynamics, different initial pedestrian densities, and positions of fire on evacuation are investigated. According to simulation results, it is found that the fire increases the air temperature and the smoke density, and decreases pedestrians’ visibility and walking velocity. Also, there is a critical initial density at the platform if achieving a safe evacuation within the required 6 minutes. Furthermore, different positions of fire set in this paper have little difference on crowd evacuation if the fire is not large enough. The suggestions provided in this paper are helpful for the subway operators to prevent major casualties. Project supported by the National Natural Science Foundation of China (Grant Nos. 61322307 and 61233001).

  3. Subway train-related fatalities in New York City: accident versus suicide.

    Science.gov (United States)

    Lin, Peter T; Gill, James R

    2009-11-01

    We examined the characteristics of subway train-related fatalities in New York City between Jan. 1, 2003 and May 31, 2007 in order to determine which factors are useful in differentiating accident from suicide. Subway train-related deaths with homicide and undetermined manners also are included. During this period, there were 211 subway train-related fatalities. The manners of death were: suicide (n = 111), accident (n = 76), undetermined (n = 20), and homicide (n = 4). The causes of death were blunt trauma (n = 206) and electrocution (n = 5). Torso transection and extremity amputation were more frequent in suicides. Antidepressant medications were more frequently detected in suicides, whereas cocaine and ethanol were more frequent in accidents. However, autopsy findings should be weighed in the context of the entire evaluation along with other circumstantial and investigative findings. In unwitnessed deaths where additional information is unavailable or discrepant, the most appropriate manner of death usually is undetermined.

  4. Causal Analysis to a Subway Accident: A Comparison of STAMP and RAIB

    Directory of Open Access Journals (Sweden)

    Zhou Yao

    2018-01-01

    Full Text Available Accident investigation and analysis after the accident, vital to prevent the occurrence of similar accident and improve the safety of the system. Different methods led to a different understanding of the accident. In this paper, a subway accident was analysed with a systemic accident analysis model – STAMP (System-Theoretic Accident Modelling and Processes. The hierarchical safety control structure was obtained, and the system-level safety constraints were obtained, controllers of the physical layer were analysed one by one, and put forward the relevant safety requirements and constraints, the dynamic analysis of the structure of the safety control is carried out, and the targeted recommendations are pointed out. In comparison with the analysis results obtained by the Rail Accident Investigation Branch (RAIB. Some useful findings have been concluded. STAMP treats safety as a control problem and reduces or eliminates causes of the accident from the controlling perspective. Whereas RAIB obtains causes of the accident by analysing the sequence of events related to the accident and reasons of these events, then chooses one(or moreevent(s as the immediate cause and some of the key events as causal factors. RAIB analysis is based on the sequential event models, but STAMP analysis provides us with a holistic, dynamic way to control system to maintain safety.

  5. Smoke flow temperature beneath tunnel ceiling for train fire at subway station: Reduced-scale experiments and correlations

    International Nuclear Information System (INIS)

    Meng, Na; Wang, Qiang; Liu, Zhaoxia; Li, Xiao; Yang, He

    2017-01-01

    Highlights: • Reduced-scale experiments on train fire at subway station. • Smoke flow temperature beneath tunnel ceiling measured and correlated. • Effect of platform-tunnel conjunction door type on smoke temperature is clarified. - Abstract: This paper is to investigate the smoke flow temperature beneath tunnel ceiling for a train on fire stopping besides a subway station. Experiments were carried out in a reduced-scale (1:10) subway station model to study the maximum smoke temperature and the longitudinal temperature distribution beneath the tunnel ceiling by considering platform-tunnel conjunction doors of two types: the full-seal platform screen door (PSD) and the full-height safety door. For the maximum temperature beneath the tunnel ceiling, it is found to be well correlated non-dimensionally with heat release rate by a 3.65 and a 2.92 power law function for the full-seal platform screen door and the full-height safety door, respectively. For the longitudinal temperature distribution along the tunnel ceiling, it can be well correlated by an exponential function for both types of platform-tunnel conjunction doors. Concerning the effect of the door type, the maximum temperature is lower and the longitudinal temperature decays faster for full-height safety door than that for full-seal PSD. This is due to that with the full-height safety door, the effective width of the tunnel ceiling is widened, which results in more heat losses from the smoke flow to the ceiling.

  6. 36 CFR 9.46 - Accidents and fires.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Accidents and fires. 9.46... MINERALS MANAGEMENT Non-Federal Oil and Gas Rights § 9.46 Accidents and fires. The operator shall take technologically feasible precautions to prevent accidents and fires, shall notify the Superintendent within 24...

  7. Research on station management in subway operation safety

    Science.gov (United States)

    Li, Yiman

    2017-10-01

    The management of subway station is an important part of the safe operation of urban subway. In order to ensure the safety of subway operation, it is necessary to study the relevant factors that affect station management. In the protection of subway safety operations on the basis of improving the quality of service, to promote the sustained and healthy development of subway stations. This paper discusses the influencing factors of subway operation accident and station management, and analyzes the specific contents of station management security for subway operation, and develops effective suppression measures. It is desirable to improve the operational quality and safety factor for subway operations.

  8. Fire-accident analysis code (FIRAC) verification

    International Nuclear Information System (INIS)

    Nichols, B.D.; Gregory, W.S.; Fenton, D.L.; Smith, P.R.

    1986-01-01

    The FIRAC computer code predicts fire-induced transients in nuclear fuel cycle facility ventilation systems. FIRAC calculates simultaneously the gas-dynamic, material transport, and heat transport transients that occur in any arbitrarily connected network system subjected to a fire. The network system may include ventilation components such as filters, dampers, ducts, and blowers. These components are connected to rooms and corridors to complete the network for moving air through the facility. An experimental ventilation system has been constructed to verify FIRAC and other accident analysis codes. The design emphasizes network system characteristics and includes multiple chambers, ducts, blowers, dampers, and filters. A larger industrial heater and a commercial dust feeder are used to inject thermal energy and aerosol mass. The facility is instrumented to measure volumetric flow rate, temperature, pressure, and aerosol concentration throughout the system. Aerosol release rates and mass accumulation on filters also are measured. We have performed a series of experiments in which a known rate of thermal energy is injected into the system. We then simulated this experiment with the FIRAC code. This paper compares and discusses the gas-dynamic and heat transport data obtained from the ventilation system experiments with those predicted by the FIRAC code. The numerically predicted data generally are within 10% of the experimental data

  9. Boating Accident Investigations 1974, Fire and Explosion

    Science.gov (United States)

    1975-04-15

    Fuel Tanks - The two 28 gallon saddle tanks were manu- factured by Aluminum Fabricated Products , Inc. of .090 in. thick 5052 aluminum. The tanks, which...Extinguishers - The boat contained two fire portable fire ext~inguishers. One Amway Model 275R-5C fire extinguisbc: was found to be in good shape. It had

  10. Feedback from practical experience with large sodium fire accidents

    International Nuclear Information System (INIS)

    Luster, V.P.; Freudenstein, K.F.

    1996-01-01

    The paper reviews the important feedback from the practical experience from two large sodium fires; the first at ALMERIA in Spain and the second in the Na laboratories at Bensberg, Germany. One of the most important sodium fire accidents was the ALMERIA spray fire accident. The origin of this accident was the repair of a valve when about 14 t of sodium was spilled in the plant room over a period of 1/2 hour. The event has been reported (IAEA/IWGFR meeting in 1988) and this presentation gives a short review of important feedback. The Almeria accident was one of the reasons that from that time spray fires had to be taken into account in the safety analyses of nuclear power plants. Due to the fact that spray fire codes were not available in a sufficiently validated state, safety analyses were provisionally based on the feedback from sodium fire tests and also from the Almeria accident itself. The behaviour of spray fires showed that severe destruction, up to melting of metallic structures may occur, but even with a large spray fire is limited roughly within the spray fire zone itself. This could be subsequently be predicted by codes like NABRAND in Germany and FEUMIX in France. Almeria accident has accelerated R and D and code development with respect to spray fires. As example for a code validation some figures are given for the NABRAND code. Another large sodium fire accident happened in 1992 in the test facility at Bensberg in Germany (ILONA). This accident occurred during preheating of a sodium filled vessel which was provisionally installed in the basement of the ILONA test facility at Bensberg. Due to failure of a pressure relief valve the pressure in the vessel increased. As a consequence the plug in a dip tube for draining the vessel failed and about 4,5 t of sodium leaked slowly from the vessel. The plant room was not cladded with steel liners or collecting pans (it was not designed for permanent sodium plant operation). So leaking sodium came directly in

  11. Comparison of safety equipment between London underground and Beijing subway

    Science.gov (United States)

    Chen, T.; Zhang, S. Y.; Zhao, L. Z.; Xia, J. J.; Fu, X. C.; Bao, Z. M.; Chen, Y.; Zhang, X. Z.; Wang, R. J.; Hu, C.; Jing, L. S.; Wang, Y.

    2017-06-01

    The purpose of this paper was to improve the safety equipment’s effectiveness through the comparison. Firstly, the history and safety accident of London Underground and Beijing Subway were shown. Secondly, fire equipment between these two cities was compared including station’s hardware installations and carriage’s hardware installations. Thirdly, the relative software installations were also compared such as emergency drills. The results showed that Beijing Subway’s hardware installations were better than London. However, London Underground’s some installations were more effective than Beijing. Both cities would pay more attention on anti-terrorist in tunnel.

  12. Benchmarking MARS (accident management software) with the Browns Ferry fire

    International Nuclear Information System (INIS)

    Dawson, S.M.; Liu, L.Y.; Raines, J.C.

    1992-01-01

    The MAAP Accident Response System (MARS) is a userfriendly computer software developed to provide management and engineering staff with the most needed insights, during actual or simulated accidents, of the current and future conditions of the plant based on current plant data and its trends. To demonstrate the reliability of the MARS code in simulatng a plant transient, MARS is being benchmarked with the available reactor pressure vessel (RPV) pressure and level data from the Browns Ferry fire. The MRS software uses the Modular Accident Analysis Program (MAAP) code as its basis to calculate plant response under accident conditions. MARS uses a limited set of plant data to initialize and track the accidnt progression. To perform this benchmark, a simulated set of plant data was constructed based on actual report data containing the information necessary to initialize MARS and keep track of plant system status throughout the accident progression. The initial Browns Ferry fire data were produced by performing a MAAP run to simulate the accident. The remaining accident simulation used actual plant data

  13. 27 CFR 555.31 - Inspection of site accidents or fires; right of entry.

    Science.gov (United States)

    2010-04-01

    ... accidents or fires; right of entry. 555.31 Section 555.31 Alcohol, Tobacco Products, and Firearms BUREAU OF... Administrative and Miscellaneous Provisions § 555.31 Inspection of site accidents or fires; right of entry. Any ATF officer may inspect the site of any accident or fire in which there is reason to believe that...

  14. Diamond Fire: Serious Accident Investigation Report

    Science.gov (United States)

    John Waconda; Ivan Pupulidy; Leonard Diaz; Robin Broyles; Roberta Junge; James Saveland

    2012-01-01

    This incident is effectively two studies. The first study, and the reason the Serious Accident Investigation Team was assembled, was due to a fatality, which the autopsy later determined to have been caused by a heart attack. The team was not aware of the cause of death for over 4 weeks after the incident occurred. However, the observed and reported cases of heat...

  15. Using fire dynamics simulator to reconstruct a hydroelectric power plant fire accident.

    Science.gov (United States)

    Chi, Jen-Hao; Wu, Sheng-Hung; Shu, Chi-Min

    2011-11-01

    The location of the hydroelectric power plant poses a high risk to occupants seeking to escape in a fire accident. Calculating the heat release rate of transformer oil as 11.5 MW/m(2), the fire at the Taiwan Dajia-River hydroelectric power plant was reconstructed using the fire dynamics simulator (FDS). The variations at the escape route of the fire hazard factors temperature, radiant heat, carbon monoxide, and oxygen were collected during the simulation to verify the causes of the serious casualties resulting from the fire. The simulated safe escape time when taking temperature changes into account is about 236 sec, 155 sec for radiant heat changes, 260 sec for carbon monoxide changes, and 235-248 sec for oxygen changes. These escape times are far less than the actual escape time of 302 sec. The simulation thus demonstrated the urgent need to improve escape options for people escaping a hydroelectric power plant fire. © 2011 American Academy of Forensic Sciences.

  16. Subway Market Research

    OpenAIRE

    Liutu, Riina

    2010-01-01

    The main goal of this thesis is to find out whether Danish entrepreneurs can become successful in the Danish market as Subway franchisees. Three specific cities, namely Århus, Horsens and Vejle, are looked at in depth. In the thesis, these three cities will represent the Danish market. An evaluation of the most suitable location for a Subway restaurant is made. To reach the above objective, the Subway franchising concept, the market situation, the customers and the competitive situation will ...

  17. Markkinointisuunnitelma Subway Joensuulle

    OpenAIRE

    Kettunen, Henna

    2014-01-01

    Opinnäytetyön aiheena oli markkinointisuunnitelman laatiminen Subway Joensuulle. Subway on pikaruokaravintola, joka tarjoaa tuoreilla raaka-aineilla täytettyä leipää, jota kutsutaan nimellä Subi®. Ensimmäinen Subway-ravintola perustettiin Joensuuhun vuonna 2008. Tällä hetkellä Joensuussa on kolme Subway-ravintolaa. Subwaylle ei ole aikaisemmin tehty kokonaisvaltaista markkinointisuunnitelmaa. Työ toteutettiin toiminnallisena opinnäytetyönä hyödyntäen yrittäjän haastatteluja, kirjallista j...

  18. A Cellular Automata-Based Simulation Tool for Real Fire Accident Prevention

    Directory of Open Access Journals (Sweden)

    Jacek M. Czerniak

    2018-01-01

    Full Text Available Many serious real-life problems could be simulated using cellular automata theory. There were a lot of fires in public places which kill many people. Proposed method, called Cellular Automata Evaluation (CAEva in short, is using cellular automata theory and could be used for checking buildings conditions for fire accident. The tests performed on real accident showed that an appropriately configured program allows obtaining a realistic simulation of human evacuation. The authors analyze some real accidents and proved that CAEva method appears as a very promising solution, especially in the cases of building renovations or temporary unavailability of escape routes.

  19. A methodology for analyzing precursors to earthquake-initiated and fire-initiated accident sequences

    International Nuclear Information System (INIS)

    Budnitz, R.J.; Lambert, H.E.; Apostolakis, G.

    1998-04-01

    This report covers work to develop a methodology for analyzing precursors to both earthquake-initiated and fire-initiated accidents at commercial nuclear power plants. Currently, the U.S. Nuclear Regulatory Commission sponsors a large ongoing project, the Accident Sequence Precursor project, to analyze the safety significance of other types of accident precursors, such as those arising from internally-initiated transients and pipe breaks, but earthquakes and fires are not within the current scope. The results of this project are that: (1) an overall step-by-step methodology has been developed for precursors to both fire-initiated and seismic-initiated potential accidents; (2) some stylized case-study examples are provided to demonstrate how the fully-developed methodology works in practice, and (3) a generic seismic-fragility date base for equipment is provided for use in seismic-precursors analyses. 44 refs., 23 figs., 16 tabs

  20. Investigations concerning fire-induced accidents in nuclear facilities

    International Nuclear Information System (INIS)

    Lamuth, P.; Lernout, L.A.; Bonneval, F.; Cottaz, M.

    1996-01-01

    In the context of fire protection in technical buildings of French nuclear facilities, three principles have been adopted: prevention, detection and fire-fighting. Their implementation makes it possible on the one hand to limit the fire ignition and the fire growth, and on the other hand to prevent fire extent which would lead to unavailability of several safety related equipment. Although progress has been made in this direction, the fire risks have still not been eliminated. It is therefore essential to evaluate the fire effects and to assess their consequences. To this end, three main R and D programs have been conducted into fires. Part I sets out the fire PSA methodology used for a 900 MWe PWR. Part II gives an outline of two fire and ventilation computer codes useful for the fire PSA. Finally, part III gives an outline of the tests already performed and those currently under way in the two laboratories of the Institut de Protection et de Surete Nucleaire (IPSN) in order to qualify the codes and provide useful information for the safety assessment. (author)

  1. Drawing subway maps : a survey

    NARCIS (Netherlands)

    Wolff, A.

    2007-01-01

    This paper deals with automating the drawing of subway maps. There are two features of schematic subway maps that make them different from drawings of other networks such as flow charts or organigrams. First, most schematic subway maps use not only horizontal and vertical lines, but also diagonals.

  2. Possibility of Fire Accident Analysis in Road Tunnel

    Directory of Open Access Journals (Sweden)

    Peter Vidmar

    2004-09-01

    Full Text Available The basic aim of this treatise is to research the relevant featuresof the control and management of fire event in road tunnels.The simulation of 200 meters long cut out of the road tunnelis performed with the computer code FDS (Fire DynamicsSimulator which is based on the computational fluid dynamics.FDS is used to simulate fire dynamics behavior in three differentscenarios: natural ventilation, forced ventilation with axialventilators and vertical smoke extraction.It is believed that the present research, the methodology appliedand its findings should promote and improve safety andreliability of fire safety in road tunnels and to cope with thecomplex contemporary logistic demands of safety and reliabilityin the transportation of passengers and goods.

  3. Labelling subway lines

    NARCIS (Netherlands)

    Garrido, M.A.; Iturriaga, C.; Márquez, A.; Portillo, J.R.; Reyes, P.; Wolff, A.; Eades, P.; Takaoka, T.

    2001-01-01

    Graphical features on map, charts, diagrams and graph drawings usually must be annotated with text labels in order to convey their meaning. In this paper we focus on a problem that arises when labeling schematized maps, e.g. for subway networks. We present algorithms for labeling points on a line

  4. The FIRAC code - its applicability and boundary conditions for fire accident analysis in a reprocessing plant

    International Nuclear Information System (INIS)

    Roewekamp, M.

    1991-01-01

    After a short description of the modelling capabilities and the implementation of the computer code the possible applications of FIRAC are demonstrated by means of two test-examples. The so gained experiences with respect to the variation of different parameters, convergency criteria, etc. can be used for the simulation of a fire accident in the storage area for unconditioned combustible low active waste (LAW) of the planned reprocessing plant at Wackersdorf. The code is prepared for calculating direct effects (of the fire) in the fire room as well as particularly effects on adjacent rooms and ventilation systems. Source terms for the release of radioactive particles outside a building can also be investigated. The temperature and pressure curves for the fire room as well as for other areas in the facility show that no damages caused by temperature effects are expected for the considered fire of low active waste. As a result of the calculated mass and volumetric flows radioactive aerosole particles could be transported into normally non-active areas. The FIRAC code renders the possibility of a more detailed analysis of those parameters relevant for fire accidents and by this means completes the so far phenomenological procedure of the fire hazard analysis in nuclear facilities. (orig.) [de

  5. 3-Dimensional numerical simulation of sodium spray fire accidents in LMFBRs

    International Nuclear Information System (INIS)

    Zhang Bin; Zhu Jizhou; Han Lang

    2005-01-01

    In order to estimate and foresee the sequence of sodium spray fires that may occur in the liquid metal cooled fast breeder reactors (LMFBRs), this paper develops a program to analyze such sodium fire accidents. The present study gives a 3-dimensional numerical analysis code for sodium spray fires. The spatial distributions of gas temperature and chemical species concentrations in the cell that sodium spray fires happened are given. This paper gives detailed explanation of combustion models and heat transfer models that applied in the program. And the calculation procedure and method in solving the fluid field are narrated in detail. Good agreements of an overall transient behavior are obtained in a sodium spray combustion test analysis. The comparison between the analytical and experimental results shows that the program presented in this paper is creditable and reasonable for simulating the sodium spray fires. (author)

  6. Concept and measures relating to transport accidents and fire when radioactivity is involved

    International Nuclear Information System (INIS)

    Spiess, R.

    1976-01-01

    Different ways of intervention and possible operational details for the behaviour of police and firemen are discussed which could take place during incidents (transport accidents and fire) where radioactivity is involvend. The importance of ways and means are pointed out which would be employed in Switzerland to overcome such a situation. (orig.) [de

  7. Aerosols released from solvent fire accidents in reprocessing plants

    International Nuclear Information System (INIS)

    Jordan, S.; Lindner, W.

    1985-01-01

    Thermodynamic, aerosol characterizing and radiological data of solvent fires in reprocessing plants have been established in experiments. These are the main results: Depending on the ventilation in the containment, kerosene-TBP mixtures burn at a rate up to 120 kg/m 2 h. The aqueous phase of inorganic-organic mixtures might be released during the fire. The gaseous reaction products contain unburnable acidic compounds. Solvents with TBP-nitrate complex shows higher (up to 25%) burning rates than pure solvents (kerosene-TBP). The nitrate complex decomposes violently at about 130 0 C with a release of acid and unburnable gases. Up to 20% of the burned kerosene-TBP solvents are released during the fire in the form of soot particles, phosphoric acid and TBP decomposition products. The particles have an aerodynamic mass median diameter of about 0.5 μm and up to 1.5% of the uranium fixed in the TBP-nitrate complex is released during solvent fires. (orig.)

  8. Research on the analytical method about influence of gas leakage and explosion on subway

    Science.gov (United States)

    Ji, Wendong; Yang, Ligong; Chen, Lin

    2018-05-01

    With the construction and development of city subway, the cross impact of underground rail transit and gas pipe network is becoming more and more serious, but there is no analytical method for the impact of gas explosions on the subway. According to this paper, the gas leakage is equivalent to the TNT explosion equivalent, based on which, the calculation of the explosive impact load is carried out. On the basis of the concrete manifestation of gas explosion, it is more convenient to carry out the subsequent calculation by equivalently treating the explosive impact load as a uniform load within a certain range. The overlying soil of the subway station has played a protective role for the subway, making the displacement of the subway structure in the explosion process significantly reduced. The analysis on the actual case shows that this method can be successfully applied to the quantitative analysis of such accidents.

  9. Deformation and Heat Transfer on Three Sides Protected Beams under Fire Accident

    Science.gov (United States)

    Imran, M.; Liew, M. S.; Garcia, E. M.; Nasif, M. S.; Yassin, A. Y. M.; Niazi, U. M.

    2018-04-01

    Fire accidents are common in oil and gas industry. The application of passive fire protection (PFP) is a costly solution. The PFP is applied only on critical structural members to optimise project cost. In some cases, beams cannot be protected from the top flange in order to accommodate for the placement of pipe supports and grating. It is important to understand the thermal and mechanical response of beam under such condition. This paper discusses the response of steel beam under ISO 834 fire protected, unprotected and three sides protected beams. The model validated against an experimental study. The experimental study has shown good agreement with FE model. The study revealed that the beams protected from three sides heat-up faster compare to fully protected beam showing different temperature gradient. However, the affects load carrying capacity are insignificant under ISO 834 fire.

  10. Effects of sodium fires on structures and materials. Practical experience with sodium leakage accidents

    International Nuclear Information System (INIS)

    Freudenstein, K.F.

    1989-01-01

    A few sodium leakage, incidents happened in SNR 300 nuclear power plant during pre-nuclear operation which were of minor importance with respect to sodium fires. The most important sodium fire accident in the past happened in the Almeria Solar platform in Spain during the attempt to repair a valve while leaving accidentally the circuit under 4 bar overpressure. Considerable damage to pipes, valves, its insulation and its support structures was observed in the influence zone of the fire. Post accident analysis gave a leaked mass of about 14 m 3 , at a sodium temperature of 225 deg. C, the leakage lasting approximately half an hour, and burning under convective heat exchange with the external air in a section of 40 m 2 up to a height of 6 m down to the catch pans. Some local temperatures were determined by metallurgical means, integral support temperatures estimated from mechanical deformation observed. From these temperatures it was concluded that a massive spray type fire must have happened. The results fall in the interpretation range of sodium-spray fire test results. (author)

  11. A probabilistic risk assessment of the LLNL Plutonium facility's evaluation basis fire operational accident

    International Nuclear Information System (INIS)

    Brumburgh, G.

    1994-01-01

    The Lawrence Livermore National Laboratory (LLNL) Plutonium Facility conducts numerous involving plutonium to include device fabrication, development of fabrication techniques, metallurgy research, and laser isotope separation. A Safety Analysis Report (SAR) for the building 332 Plutonium Facility was completed rational safety and acceptable risk to employees, the public, government property, and the environment. This paper outlines the PRA analysis of the Evaluation Basis Fire (EDF) operational accident. The EBF postulates the worst-case programmatic impact event for the Plutonium Facility

  12. Statistical aspects of carbon fiber risk assessment modeling. [fire accidents involving aircraft

    Science.gov (United States)

    Gross, D.; Miller, D. R.; Soland, R. M.

    1980-01-01

    The probabilistic and statistical aspects of the carbon fiber risk assessment modeling of fire accidents involving commercial aircraft are examined. Three major sources of uncertainty in the modeling effort are identified. These are: (1) imprecise knowledge in establishing the model; (2) parameter estimation; and (3)Monte Carlo sampling error. All three sources of uncertainty are treated and statistical procedures are utilized and/or developed to control them wherever possible.

  13. Effect of hyperbaric oxygen therapy on whole blood cyanide concentrations in carbon monoxide intoxicated patients from fire accidents

    DEFF Research Database (Denmark)

    Lawson-Smith, Pia; Jansen, Erik C; Hilsted, Linda

    2010-01-01

    Hydrogen cyanide (HCN) and carbon monoxide (CO) may be important components of smoke from fire accidents. Accordingly, patients admitted to hospital from fire accidents may have been exposed to both HCN and CO. Cyanide (CN) intoxication results in cytotoxic hypoxia leading to organ dysfunction...... and animal experiments have shown that in rats exposed to CN intoxication, HBO can increase the concentration of CN in whole blood....

  14. Verification of fire and explosion accident analysis codes (facility design and preliminary results)

    International Nuclear Information System (INIS)

    Gregory, W.S.; Nichols, B.D.; Talbott, D.V.; Smith, P.R.; Fenton, D.L.

    1985-01-01

    For several years, the US Nuclear Regulatory Commission has sponsored the development of methods for improving capabilities to analyze the effects of postulated accidents in nuclear facilities; the accidents of interest are those that could occur during nuclear materials handling. At the Los Alamos National Laboratory, this program has resulted in three computer codes: FIRAC, EXPAC, and TORAC. These codes are designed to predict the effects of fires, explosions, and tornadoes in nuclear facilities. Particular emphasis is placed on the movement of airborne radioactive material through the gaseous effluent treatment system of a nuclear installation. The design, construction, and calibration of an experimental ventilation system to verify the fire and explosion accident analysis codes are described. The facility features a large industrial heater and several aerosol smoke generators that are used to simulate fires. Both injected thermal energy and aerosol mass can be controlled using this equipment. Explosions are simulated with H 2 /O 2 balloons and small explosive charges. Experimental measurements of temperature, energy, aerosol release rates, smoke concentration, and mass accumulation on HEPA filters can be made. Volumetric flow rate and differential pressures also are monitored. The initial experiments involve varying parameters such as thermal and aerosol rate and ventilation flow rate. FIRAC prediction results are presented. 10 figs

  15. Computer code TRANS-ACE predicting for fire and explosion accidents in nuclear fuel reprocessing plants

    International Nuclear Information System (INIS)

    Abe, Hitoshi; Nishio; Gunji; Naito, Yoshitaka

    1993-11-01

    The accident analysis code TRANS-ACE was developed to evaluate the safety of a ventilation system in a reprocessing plant in the event of fire and explosion accidents. TRANS-ACE can evaluate not only the integrity of a ventilation system containing HEPA filters but also the source term of radioactive materials for release out of a plant. It calculates the temperature, pressure, flow rate, transport of combustion materials and confinement of radioactive materials in the network of a ventilation system that might experience a fire or explosion accident. TRANS-ACE is based on the one-dimensional compressible thermo-fluid analysis code EVENT developed by Los Alamos National Laboratory (LANL). Calculational functions are added for the radioactive source term, heat transfer and radiation to cell and duct walls and HEPA filter integrity. For the second edition in the report, TRANS-ACE has been improved incorporating functions for the initial steady-state calculation to determine the flow rates, pressure drops and temperature in the network before an accident mode analysis. It is also improved to include flow resistance calculations of the filters and blowers in the network and to have an easy to use code by simplifying the input formats. This report is to prepare an explanation of the mathematical model for TRANS-ACE code and to be the user's manual. (author)

  16. Advances in safety countermeasures at the Tomari NPP of Hokkaido Electric Power on the basis of Fukushima Daiichi NPP accident. Fire protection and other advances

    International Nuclear Information System (INIS)

    Shibata, Taku; Dasai, Katsumi

    2014-01-01

    Fire protections for the nuclear power plants have been based on the fire laws and the conventional guide. After Fukushima Daiichi NPP accident, many safety countermeasures - also about Fire Protection - have been discussed in the Japanese authorities. This paper shows our present activities in the Tomari NPP about the fire protections from the view points of Fire Prevention, Fire Detection/Suppression Systems and Fire Protection, and other advances. (author)

  17. 41 CFR 102-74.360 - What are the specific accident and fire prevention responsibilities of occupant agencies?

    Science.gov (United States)

    2010-07-01

    ... other hanging materials that are made of non-combustible or flame-resistant fabric; (f) Use only... resistant; (g) Cooperate with GSA to develop and maintain fire prevention programs that provide the maximum... accident and fire prevention responsibilities of occupant agencies? 102-74.360 Section 102-74.360 Public...

  18. Transplanetary subway systems

    Energy Technology Data Exchange (ETDEWEB)

    Salter, R M

    1978-10-01

    Planetran, a global subway system consisting of carriages that are electromagnetically supported and propelled through evacuated tubes, is proposed. Speeds of 300 mph have been attained by transit vehicles using magnetic levitation. The fastest Planetran route modeled assumes a maximum speed of 14,000 mph and one gravity propulsion. Passenger response to high acceleration is unknown. The cost of a U.S. coast to coast system is estimated at $500 billion. Advantages include high speed transport, energy efficiency, reduced pollution, less land taken from agriculture, and associated benefits of transporting other materials in adjacent pipelines. No new scientific breakthroughs would be needed to develop this system. Military sponsorship is proposed to overcome resistance to the considerable financial outlay. (7 diagrams, 1 map)

  19. A probabilistic risk assessment of the LLNL Plutonium Facility's evaluation basis fire operational accident. Revision 1

    International Nuclear Information System (INIS)

    Brumburgh, G.P.

    1995-01-01

    The Lawrence Livermore National Laboratory (LLNL) Plutonium Facility conducts numerous programmatic activities involving plutonium to include device fabrication, development of improved and/or unique fabrication techniques, metallurgy research, and laser isotope separation. A Safety Analysis Report (SAR) for the building 332 Plutonium Facility was completed in July 1994 to address operational safety and acceptable risk to employees, the public, government property, and the environmental. This paper outlines the PRA analysis of the Evaluation Basis Fire (EBF) operational accident. The EBF postulates the worst-case programmatic impact event for the Plutonium Facility

  20. Investigation of effect of stopping supply flow into the cell on the confinement of the radioactive materials under fire accident

    International Nuclear Information System (INIS)

    Abe, Hitoshi; Watanabe, Koji

    1999-03-01

    On November 20th 1997, a fire accident happened at Uranium Enrichment Research Laboratory, Tokai, Japan Atomic Energy Research Institute and ventilation filters in the laboratory clogged. When fire accident occurs in a controlled area, a large quantity of smoke generates in the area and dropping exhaust flow from the area by the clogging of ventilation filters and rising pressure in the area are caused. Moreover, leakage of smoke including radioactive materials from the area by the pressure rising is expected. To prevent the leakage, it is expected that stopping supply flow to the area during a fire accident is effective, however, quantitative evaluation about this effect has not been performed. By using CELVA-1D code, one-dimensional thermofluid analysis code, this effect is evaluated quantitatively by modeling the laboratory and estimating source terms released during the fire accident. As the results, it has been found that the efficiency of confinement of the radioactive materials into the area is preserved in the slightly long period of time in case of stopping supply flow to the area, however, this effect can be neglected in case that scale of fire accident is relatively large. (author)

  1. A demonstrator for an integrated subway protection system

    Science.gov (United States)

    Detoma, E.; Capetti, P.; Casati, G.; Billington, S.

    2008-04-01

    commercial sensors and deployed in a new station of the Naples metropolitan transit system in Mugnano. The station was particularly suitable for the demonstration since it is a new station that includes air venting control, water barriers (for fire and smoke containment) and a complete SCADA system to integrate technical and video surveillance operations. In order to protect the subway, we tackled four basic technologies, all readily available in-house or on the market: - radiation detection, to detect the introduction in the station of radionuclides, that may be dispersed by conventional explosive (a "dirty" bomb); - chemical agents detection and identification (after release), complemented with air speed and velocity sensors to estimate, track and predict the contamination plume; - video surveillance, integrated with the SCADA system and already available in the station.

  2. Thermal Analysis Of A 9975 Package In A Facility Fire Accident

    International Nuclear Information System (INIS)

    Gupta, N.

    2011-01-01

    Surplus plutonium bearing materials in the U.S. Department of Energy (DOE) complex are stored in the 3013 containers that are designed to meet the requirements of the DOE standard DOE-STD-3013. The 3013 containers are in turn packaged inside 9975 packages that are designed to meet the NRC 10 CFR Part 71 regulatory requirements for transporting the Type B fissile materials across the DOE complex. The design requirements for the hypothetical accident conditions (HAC) involving a fire are given in 10 CFR 71.73. The 9975 packages are stored at the DOE Savannah River Site in the K-Area Material Storage (KAMS) facility for long term of up to 50 years. The design requirements for safe storage in KAMS facility containing multiple sources of combustible materials are far more challenging than the HAC requirements in 10 CFR 71.73. While the 10 CFR 71.73 postulates an HAC fire of 1475 F and 30 minutes duration, the facility fire calls for a fire of 1500 F and 86 duration. This paper describes a methodology and the analysis results that meet the design limits of the 9975 component and demonstrate the robustness of the 9975 package.

  3. Evaluation of an accident management strategy of emergency water injection using fire engines in a typical pressurized water reactor

    International Nuclear Information System (INIS)

    Park, Soo Yong; Ahn, Kwang Il

    2015-01-01

    Following the Fukushima accident, a special safety inspection was conducted in Korea. The inspection results show that Korean nuclear power plants have no imminent risk for expected maximum potential earthquake or coastal flooding. However long- and short-term safety improvements do need to be implemented. One of the measures to increase the mitigation capability during a prolonged station blackout (SBO) accident is installing injection flow paths to provide emergency cooling water of external sources using fire engines to the steam generators or reactor cooling systems. This paper illustrates an evaluation of the effectiveness of external cooling water injection strategies using fire trucks during a potential extended SBO accident in a 1,000 MWe pressurized water reactor. With regard to the effectiveness of external cooling water injection strategies using fire engines, the strategies are judged to be very feasible for a long-term SBO, but are not likely to be effective for a short-term SBO

  4. Evaluation of an accident management strategy of emergency water injection using fire engines in a typical pressurized water reactor

    Energy Technology Data Exchange (ETDEWEB)

    Park, Soo Yong; Ahn, Kwang Il [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Following the Fukushima accident, a special safety inspection was conducted in Korea. The inspection results show that Korean nuclear power plants have no imminent risk for expected maximum potential earthquake or coastal flooding. However long- and short-term safety improvements do need to be implemented. One of the measures to increase the mitigation capability during a prolonged station blackout (SBO) accident is installing injection flow paths to provide emergency cooling water of external sources using fire engines to the steam generators or reactor cooling systems. This paper illustrates an evaluation of the effectiveness of external cooling water injection strategies using fire trucks during a potential extended SBO accident in a 1,000 MWe pressurized water reactor. With regard to the effectiveness of external cooling water injection strategies using fire engines, the strategies are judged to be very feasible for a long-term SBO, but are not likely to be effective for a short-term SBO.

  5. The Influence of subway climatology on gas dispersion and the effectiveness of guided evacuations in a complex subway station

    Directory of Open Access Journals (Sweden)

    Markus Brüne

    2016-09-01

    Full Text Available This paper discusses a strategy that integrates data from tracer gas experiments with results from pedestrian simulation software in the evaluation of different evacuation procedures for subway stations in response to a fire or a terrorist attack with chemical, biological, radiological, nuclear and enhanced conventional weapons (CBRNE. The study demonstrates that by combining the two data sets a greater understanding of the impact of different evacuations routes on an evacuee's health is gained. It is shown that by controlling the routes pedestrians would use to exit a subway station, the number of fatalities and evacuees with long term health issues can be reduced. It is highlighted that a dynamic evacuation guiding system based on subway climatology would take into account the source of the toxin, the resulting dispersal of gas, smoke, etc. and the subway climatology at the time. In doing so, it would be possible to identify the most endangered areas and guide passengers via an adaptive escape route using audio and visual techniques. Information on the evolution of the emergency situation could also simultaneously be relayed back to the rescue forces to help to plan the rescue and evacuation procedures and optimise the deployment of the search and rescue teams.

  6. Effect of hyperbaric oxygen therapy on whole blood cyanide concentrations in carbon monoxide intoxicated patients from fire accidents

    DEFF Research Database (Denmark)

    Lawson-Smith, Pia; Jansen, Erik C; Hilsted, Linda

    2010-01-01

    Hydrogen cyanide (HCN) and carbon monoxide (CO) may be important components of smoke from fire accidents. Accordingly, patients admitted to hospital from fire accidents may have been exposed to both HCN and CO. Cyanide (CN) intoxication results in cytotoxic hypoxia leading to organ dysfunction...... and possibly death. While several reports support the use of hyperbaric oxygen therapy (HBO) for the treatment of severe CO poisoning, limited data exist on the effect of HBO during CN poisoning. HBO increases the elimination rate of CO haemoglobin in proportion to the increased oxygen partial pressure...

  7. Safety during sea transport of radioactive materials. Probabilistic safety analysis of package fro sea surface fire accident

    International Nuclear Information System (INIS)

    Matsuoka, Takeshi; Obara, Isonori; Akutsu, Yukio; Aritomi, Masanori

    2000-01-01

    The ships carrying irradiated nuclear fuel, plutonium and high level radioactive wastes(INF materials) are designed to keep integrity of packaging based on the various safety and fireproof measures, even if the ship encounters a maritime fire accident. However, granted that the frequency is very low, realistic severe accidents should be evaluated. In this paper, probabilistic safety assessment method is applied to evaluate safety margin for severe sea fire accidents using event tree analysis. Based on our separate studies, the severest scenario was estimated as follows; an INF transport ship collides with oil tanker and induces a sea surface fire. Probability data such as ship's collision, oil leakage, ignition, escape from fire region, operations of cask cooling system and water flooding systems were also introduced from above mentioned studies. The results indicate that the probability of which packages cannot keep their integrity during the sea surface fire accident is very low and sea transport of INF materials is carried out very safely. (author)

  8. 41 CFR 102-80.80 - With what general accident and fire prevention policy must Federal agencies comply?

    Science.gov (United States)

    2010-07-01

    ... agencies must— (a) Comply with the occupational safety and health standards established in the Occupational... Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention § 102...

  9. Management of evacuation in case of fire accidents in chemical industrial areas

    International Nuclear Information System (INIS)

    Reniers, G.L.L.; Pauwels, N.; Audenaert, A.; Ale, B.J.M.; Soudan, K.

    2007-01-01

    Trade-offs between economic and safety arguments exist in the operation of chemical installations, should knock-on calamities induced by fire accidents occur: a sudden installation shutdown might result in substantial economic losses, but may be needed to ensure safety. Due to the very rare nature of domino effect risks induced decision problems an adequate evacuation decision aid model to be used by plant safety management does, to the best of the authors' knowledge, not exist. This paper develops a tentative approach to calculate the economic gains and/or losses linked to the decision problem whether or not, and when, to evacuate chemical installation(s) threatened by possible domino effect risks. The proposed model is illustrated by a case-study based on empirical data

  10. Emergency preparedness and response in case of a fire accident with (UF6) packages tracking Suez Canal

    International Nuclear Information System (INIS)

    Salama, M.

    2004-01-01

    Egypt has a unique problem - the Suez Canal. Radioactive cargo passing regularly through the canal carrying new and spent reactor fuel. Moreover there are also about 1000 metric tons of uranium hexaflouride (UF6) passing through the canal every year. In spite of all precautions taken in the transportation, accidents with packages containing (UF 6 ) and shipped through the Suez Canal, accidents may arise even though the probability is minimal. These accidents, may be accompanied by injuries or death of persons and damage to property. Due to the radiation and criticality hazards of (UF 6 ) and its high risk of chemical toxicity. The probability of a fire accident with a cargo carrying (UF 6 ) during its crossing the Suez Canal can cause serious chemical toxic and radiological hazards, particularly if the accident occurred close or near to one of the three densely populated cities (Port-Said, Ismailia, and Suez), which are located along the Suez Canal, west bank. The government of Egypt has elaborated a national radiological emergency plan inorder to face probable radiological accidents, which may be arised inside the country. Arrangements have been also elaborated for the medical care of any persons who, might be injured or contaminated, or who, have been exposed to severe radiation doses. The motivation of the present paper was undertaken to visualize a fire accident scenario occurring in industrial packages containing UF6 on board of a Cargo crossing the Suez Canal near Port-Said City. The accident scenario and emergency response actions taken during the different phases of the accident are going to be presented and discussed. The proposed emergency response actions taken to face the accident are going to be also presented. The work presented had revealed the importance of public awareness will be needed for populations located in densely populated areas along Suez Canal bank inorder to react timely and effectively to avoid the toxic and radiological hazards

  11. Emergency preparedness and response in case of a fire accident with (UF{sub 6}) packages tracking Suez Canal

    Energy Technology Data Exchange (ETDEWEB)

    Salama, M. [National Center for Nuclear Safety and Radiation Control (NCNSRC), Nasr City, Cairo (Egypt)

    2004-07-01

    Egypt has a unique problem - the Suez Canal. Radioactive cargo passing regularly through the canal carrying new and spent reactor fuel. Moreover there are also about 1000 metric tons of uranium hexaflouride (UF6) passing through the canal every year. In spite of all precautions taken in the transportation, accidents with packages containing (UF{sub 6}) and shipped through the Suez Canal, accidents may arise even though the probability is minimal. These accidents, may be accompanied by injuries or death of persons and damage to property. Due to the radiation and criticality hazards of (UF{sub 6}) and its high risk of chemical toxicity. The probability of a fire accident with a cargo carrying (UF{sub 6}) during its crossing the Suez Canal can cause serious chemical toxic and radiological hazards, particularly if the accident occurred close or near to one of the three densely populated cities (Port-Said, Ismailia, and Suez), which are located along the Suez Canal, west bank. The government of Egypt has elaborated a national radiological emergency plan inorder to face probable radiological accidents, which may be arised inside the country. Arrangements have been also elaborated for the medical care of any persons who, might be injured or contaminated, or who, have been exposed to severe radiation doses. The motivation of the present paper was undertaken to visualize a fire accident scenario occurring in industrial packages containing UF6 on board of a Cargo crossing the Suez Canal near Port-Said City. The accident scenario and emergency response actions taken during the different phases of the accident are going to be presented and discussed. The proposed emergency response actions taken to face the accident are going to be also presented. The work presented had revealed the importance of public awareness will be needed for populations located in densely populated areas along Suez Canal bank inorder to react timely and effectively to avoid the toxic and radiological

  12. Emergency preparedness and response in case of a fire accident with UF6 packages traversing the Suez Canal

    International Nuclear Information System (INIS)

    Salama, M.

    2004-01-01

    Egypt has a unique problem, the Suez Canal. Radioactive cargo passes regularly through the canal carrying new and spent reactor fuel. There are also about 1000 metric tonnes of uranium hexafluoride (UF 6 ) passing through the canal every year. In spite of all the precautions taken in the transport, accidents with packages containing UF 6 shipped through the Suez Canal may arise, even though the probability is minimal. Such accidents may be accompanied by injuries to or death of persons and damage to property including radiation and criticality hazards and high chemical toxicity, particularly if the accident occurred close to one of the three densely populated cities (Port Said, Ismailia and Suez), which are located along the west bank of the Suez Canal. The government of Egypt has established a national radiological emergency plan in order to deal with any radiological accidents which may arise inside the country. This paper considers the effect of a fire accident to industrial packages containing UF 6 on board a cargo ship passing along the Suez Canal near Port Said City. The accident scenario and emergency response actions taken during the different phases of the accident are presented and discussed. The paper highlights the importance of public awareness for populations located in densely populated areas along the bank of the Suez Canal, in order to react in a timely and effective way to avoid the toxic and radiological hazards resulting from such a type of accident. The possibility of upgrading the capabilities of civil defence and fire-fighting personnel is also discussed (author)

  13. Safety demonstration tests of postulated solvent fire accidents in extraction process of a fuel reprocessing plant, (2)

    International Nuclear Information System (INIS)

    Tukamoto, Michio; Takada, Junichi; Koike, Tadao; Nishio, Gunji; Uno, Seiichiro; Kamoshida, Atsusi; Watanabe, Hironori; Hashimoto, Kazuichiro; Kitani, Susumu.

    1992-03-01

    Demonstration tests of hypothetical solvent fire in an extraction process of the reprocessing plant were carried out from 1984 to 1985 in JAERI, focusing on the confinement of radioactive materials during the fire by a large-scale fire facility (FFF) to evaluate the safety of air-ventilation system in the plant. Fire data from the demonstration test were obtained by focusing on fire behavior at cells and ducts in the ventilation system, smoke generation during the fire, transport and deposition of smoke containing simulated radioactive species in the ventilation system, confinement of radioactive materials, and integrity of HEPA filters by using the FFF simulating an air-ventilation system of the reference reprocessing plant in Japan. The present report is published in a series of the report Phase I (JAERI-M 91-145) of the demonstration test. Test results in the report will be used for the verification of a computer code FACE to evaluate the safety of postulated fire accidents in the reprocessing plant. (author)

  14. Emergency evacuation models in subway service systems: An application on Izmir (Turkey subway system

    Directory of Open Access Journals (Sweden)

    Gökçe Baysal Türkölmez

    2016-08-01

    Full Text Available Increasing population in crowded cities causes transportation problems. Public transportation is an effective solution for the crowded traffic. Subway is a fast and productive alternative for public transportation so it is a highly preferable choice in others. It is hard to evacuate people in subway station during a disaster in carriages, on subway line or in subway stations because subway systems are often located underground, a lot people use it at the same time and enter-exit gates are controlled by turnstiles. It is crucially important to know the evacuation time of people from subway. In this paper, Konak station, one of the most crowded stations of Izmir Subway System is analyzed by emergency evacuation models. The evacuation process is simulated by Simulex software. The emergency evacuation problem is modeled in three different scenarios. Solution offers are developed for them.

  15. Evaluation of an accident management strategy of emergency water injection using fire engines in a typical pressurized water reactor

    Directory of Open Access Journals (Sweden)

    Soo-Yong Park

    2015-10-01

    Full Text Available Following the Fukushima accident, a special safety inspection was conducted in Korea. The inspection results show that Korean nuclear power plants have no imminent risk for expected maximum potential earthquake or coastal flooding. However long- and short-term safety improvements do need to be implemented. One of the measures to increase the mitigation capability during a prolonged station blackout (SBO accident is installing injection flow paths to provide emergency cooling water of external sources using fire engines to the steam generators or reactor cooling systems. This paper illustrates an evaluation of the effectiveness of external cooling water injection strategies using fire trucks during a potential extended SBO accident in a 1,000 MWe pressurized water reactor. With regard to the effectiveness of external cooling water injection strategies using fire engines, the strategies are judged to be very feasible for a long-term SBO, but are not likely to be effective for a short-term SBO.

  16. Cause finding experiments and environmental analysis on the accident of the fire and explosion in TRP bituminization facility

    International Nuclear Information System (INIS)

    Fujine, Sachio; Murata, Mikio; Abe, Hitoshi

    1999-09-01

    This report is the summary of the cause finding experiments and environmental analysis on the accident of the fire and explosion occurred at March 11th, 1997, in TRP bituminization facility of PNC (Power Reactor and Nuclear Fuel Development Corporation). Regarding the cause finding experiments, chemical components have been analyzed for the effluent samples taken from PNC's facility, bituminized mock waste has been produced using the simulated salt effluent prepared according to the results of chemical analysis, thermal analysis and experiment of runaway exothermic reaction have been conducted using the mock waste, and the component of flammable gases emitted from the heated waste have been collected and analyzed. Regarding environmental analysis on the accident, the amount of radioactive cesium released by the accident has been calculated by the comparative analysis using the atmospheric dispersion simulation code SPEEDI with the data of environmental monitoring and the public dose has been assessed. (author)

  17. Myocardial infarction in Swedish subway drivers.

    Science.gov (United States)

    Bigert, Carolina; Klerdal, Kristina; Hammar, Niklas; Gustavsson, Per

    2007-08-01

    Particulate matter in urban air is associated with the risk of myocardial infarction in the general population. Very high levels of airborne particles have been detected in the subway system of Stockholm, as well as in several other large cities. This situation has caused concern for negative health effects among subway staff. The aim of this study was to investigate whether there is an increased incidence of myocardial infarction among subway drivers. Data from a population-based case-control study of men aged 40-69 in Stockholm County in 1976-1996 were used. The study included all first events of myocardial infarction in registers of hospital discharges and deaths. The controls were selected randomly from the general population. National censuses were used for information on occupation. Altogether, 22 311 cases and 131 496 controls were included. Among these, 54 cases and 250 controls had worked as subway drivers. The relative risk of myocardial infarction among subway drivers was not increased. It was 0.92 [95% confidence interval (95% CI) 0.68-1.25] when the subway drivers were compared with other manual workers and 1.06 (95% CI 0.78-1.43) when the subway drivers were compared with all other gainfully employed men. Subgroup analyses indicated no influence on the risk of myocardial infarction from the duration of employment, latency time, or time since employment stopped. Subway drivers in Stockholm do not have a higher incidence of myocardial infarction than other employed persons.

  18. FIRAC: a computer code to predict fire-accident effects in nuclear facilities

    International Nuclear Information System (INIS)

    Bolstad, J.W.; Krause, F.R.; Tang, P.K.; Andrae, R.W.; Martin, R.A.; Gregory, W.S.

    1983-01-01

    FIRAC is a medium-sized computer code designed to predict fire-induced flows, temperatures, and material transport within the ventilating systems and other airflow pathways in nuclear-related facilities. The code is designed to analyze the behavior of interconnected networks of rooms and typical ventilation system components. This code is one in a family of computer codes that is designed to provide improved methods of safety analysis for the nuclear industry. The structure of this code closely follows that of the previously developed TVENT and EVENT codes. Because a lumped-parameter formulation is used, this code is particularly suitable for calculating the effects of fires in the far field (that is, in regions removed from the fire compartment), where the fire may be represented parametrically. However, a fire compartment model to simulate conditions in the enclosure is included. This model provides transport source terms to the ventilation system that can affect its operation and in turn affect the fire

  19. Radiation management at the occurrence of accident and restoration works. Fire and explosion of asphalt solidification processing facility

    Energy Technology Data Exchange (ETDEWEB)

    Miyabe, Kenjiro; Jin, K; Namiki, A; Mizutani, K; Horiuchi, N; Saruta, J [Power Reactor and Nuclear Fuel Development Corp., Health and Safety Division, Tokai, Ibaraki (Japan); Ninomiya, Kazushige [Power Reactor and Nuclear Fuel Development Corp., Tsuruga, Fukui (Japan). Monju Construction Office

    1998-06-01

    Fire and explosion accident in the cell of Asphalt Solidification Processing Facility(ASP) in PNC took placed at March 11 in 1997. Following to the alarm of many radiation monitoring system in the facility, some of workers inhale radioactive materials in their bodies. Indication values of an exhaust monitor installed in the first auxiliary exhaust stack increased suddenly. A large number of windows, doors, and shutters in the facility were raptured by the explosion. A lot of radioactive materials blew up and were released to the outside of the facility. Reinforcement of radiation surveillance function, nose smearing test for the workers and confirmation of contamination situation were implemented on the fire. Investigation of radiation situation, radiation management on the site, exposure management for the workers, surveillance of exhaustion, and restoration works of the damaged radiation management monitoring system were carried out after the explosion. The detailed data of radiation management measures taken during three months after the accident are described in the paper. (M. Suetake)

  20. Release behavior of smoke and clogging characteristics of the ventilation filter under the fire accident. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Takada, Junichi; Watanabe, Koji; Tsukamoto, Michio; Tashiro, Shinsuke [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Hayashi, Shiro [Nippon Muki Corp., Tokyo (Japan); Takita, Koji [Sanzo Environment Engineering Corp., Tokyo (Japan); Abe, Hitoshi [Ministry of Economy Trade and Industry, Tokyo (Japan); Uchiyama, Gunzo [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan)

    2003-01-01

    In a part of building ventilating installation of reprocessing plant, the pre-filter is equipped in front of a HEPA filter. The pre-filter plays a role in protection and repression of clogging of HEPA filter. However, in a fire accident, it is considered that large smoke generation cause the pre-filter clogging due to smoke loading, increase of differential pressure and breakdown. In Japan Atomic Energy Research Institute, the demonstration tests to confirm the performance of ventilation filters by a fire accident were carried out. In the tests, smoke was generated from burning of the mock solid wastes (gloves made of rubber and/or cloth) or the mock recovered solvent (n-dodecane or tributyl phosphate / n-dodecane). The test data was acquired on generation of smoke, decrease evolution of smoke by transportation through the compositions of ventilation system (cell, duct, damper, filters) and clogging characteristics of the ventilation filters due to smoke loading. From the results, it was found that the performance of the whole of ventilation system was kept even if the pre-filter was breakdown. To adopt the analysis of the increase of differential pressure across the pre-filter using the safety analysis code, CELVA-1D, increase of differential pressure across the pre-filter was expressed by quadratic empirical equation with function of smoke loading per unit filtration area and it coefficients, ({alpha}, {beta}), were estimated. (author)

  1. Temporal and spatial patterns of suicides in Stockholm's subway stations.

    Science.gov (United States)

    Uittenbogaard, Adriaan; Ceccato, Vania

    2015-08-01

    This paper investigates the potential temporal and spatial variations of suicides in subway stations in Stockholm, Sweden. The study also assesses whether the variation in suicide rates is related to the station environments by controlling for each station's location and a number of contextual factors using regression models and geographical information systems (GIS). Data on accidents are used as references for the analysis of suicides. Findings show that suicides tend to occur during the day and in the spring. They are concentrated in the main transportation hubs but, interestingly, during off-peak hours. However, the highest rates of suicides per passenger are found in Stockholm's subway stations located in the Southern outskirts. More than half of the variation in suicide rates is associated with stations that have walls between the two sides of the platform but still allow some visibility from passers-by. The surrounding environment and socioeconomic context show little effect on suicide rates, but stations embedded in areas with high drug-related crime rates tend to show higher suicide rates. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. The association between psychiatric disorders and work-related problems among subway drivers in Korea.

    Science.gov (United States)

    Kim, Se-Eun; Kim, Hyoung-Ryoul; Park, Jong-Ik; Lee, Hae Woo; Lee, Jongin; Byun, Junsu; Yim, Hyeon Woo

    2014-01-01

    This study aimed to find the prevalence and occupational risk factors for major psychiatric disorders among subway drivers in South Korea. Of all 998 current subway drivers, 995 participated in this study. The Korean version of the Composite International Diagnostic Interview (K-CIDI 2.1) was administered by trained interviewers to diagnose psychiatric disorders in all participants. The questions on socio-demographic characteristics and working conditions included some questions related to a person under train (PUT) experience and work-related problems. One-year prevalence and lifetime prevalence of major depressive disorder (MDD), post-traumatic stress disorder (PTSD), and panic disorder were diagnosed through the interview. The standardized prevalence ratios (SPRs) of these three disorders were calculated in the sample of subway drivers using the 2011 Korean National Epidemiologic Survey data as a basis. Multiple logistic regressions were performed to determine the association between work-related factors and the prevalence of the psychiatric disorders. The standardized prevalence ratios (SPRs) for a 1-year prevalence of MDD and PTSD among subway drivers were 1.1 (95% CI 0.7-1.7) and 5.6 (95% CI 3.1-8.8), respectively. Conflict with passengers was significantly associated with an increased risk for both MDD and PTSD in 1-year and in lifetime prevalence. Experiencing a sudden stop due to an emergency bell increased the risk of the lifetime prevalence of MDD (OR 2.61, 95% CI 1.14-6.97) and PTSD (OR 7.53, 95% CI 1.77-32.02). The risk of PTSD significantly increased among drivers who once experienced a near accident in terms of both the 1-year prevalence (OR 8.81, 95% CI 1.96-39.3) and the lifetime prevalence (OR 6.36, 95% CI 2.40-16.90). PTSD and panic disorder were more prevalent among subway drivers than in the general population. We found that having a conflict with passengers, a near accident, and a breakdown while driving can be risk factors for psychiatric

  3. The analysis outlining the occurrence and consequences of accidents in the work environment of the firefighters employed by the State Fire Service in Poland in 2008-2013.

    Science.gov (United States)

    Pawlak, Agata; Gotlib, Joanna; Gałązkowski, Robert

    2016-01-01

    Due to the specifics of their work and to being exposed to a wide range of hazards, firefighters working for the State Fire Service (SFS) face the risk of work-related accidents more often than members of other occupational groups. The aim of this paper is to analyze the occurrence and consequences of accidents in the work environment of the SFS officers in Poland between the years 2008-2013. The material analyzed is based on aggregate data collected by the Headquarters of the State Fire Service. Figures regarding accidents in the period between 1 January 2008 and 31 December 2013 show that 8518 work-related accidents occurred in that period and 8635 people were injured. The data shows that neither the number of accidents nor their frequency indicator underwent any significant fluctuations over the 6 years under consideration. The group that is most exposed to accidents on duty in the profession includes active firefighters serving in rescue and fire extinguishment divisions. According to the data, the greatest number of trauma incidents in the SFS between the years 2008-2013 occurred during sporting activities. The predominant cause of these was inappropriate behavior or the lack of proper care. The most frequent injuries sustained during the accidents were broken or fractured bones and sprained joints. Accidents on duty occur significantly more often when firefighters are at their stations, during sporting classes, exercises or maneuvers, than in the course of actual rescue operations. The firefighters of the State Fire Services are insufficiently prepared for their sporting activities. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  4. The Effectiveness of Behavior Therapy and Symptoms of PTSD in Trauma Survivors Fire Accident in Industrial Pole of Shahid Babaie City Shazand

    OpenAIRE

    M. Sadeghi; M. Naderi-Nabi; M. Chegini; A. Ghaedniaye-Jahromi

    2015-01-01

    Background: The aim of this present study was to the effectiveness of behavior therapy in the treatment of posttraumatic stress disorder symptoms and general health of in Trauma Survivors Fire Accident in Industrial Pole of Shahid Babaie City Shazand in 1387. Methods: The present plan study of experimental design with pre - and post - test method after the test. community study all the survivors industrial hub of fire martyr Babaie city shazand township to approach the census initial screenin...

  5. FIRAC - a computer code to predict fire accident effects in nuclear facilities

    International Nuclear Information System (INIS)

    Bolstad, J.W.; Foster, R.D.; Gregory, W.S.

    1983-01-01

    FIRAC is a medium-sized computer code designed to predict fire-induced flows, temperatures, and material transport within the ventilating systems and other airflow pathways in nuclear-related facilities. The code is designed to analyze the behavior of interconnected networks of rooms and typical ventilation system components. This code is one in a family of computer codes that is designed to provide improved methods of safety analysis for the nuclear industry. The structure of this code closely follows that of the previously developed TVENT and EVENT codes. Because a lumped-parameter formulation is used, this code is particularly suitable for calculating the effects of fires in the far field (that is, in regions removed from the fire compartment), where the fire may be represented parametrically. However, a fire compartment model to simulate conditions in the enclosure is included. This model provides transport source terms to the ventilation system that can affect its operation and in turn affect the fire. A basic material transport capability that features the effects of convection, deposition, entrainment, and filtration of material is included. The interrelated effects of filter plugging, heat transfer, gas dynamics, and material transport are taken into account. In this paper the authors summarize the physical models used to describe the gas dynamics, material transport, and heat transfer processes. They also illustrate how a typical facility is modeled using the code

  6. Random matrices and the New York City subway system

    Science.gov (United States)

    Jagannath, Aukosh; Trogdon, Thomas

    2017-09-01

    We analyze subway arrival times in the New York City subway system. We find regimes where the gaps between trains are well modeled by (unitarily invariant) random matrix statistics and Poisson statistics. The departure from random matrix statistics is captured by the value of the Coulomb potential along the subway route. This departure becomes more pronounced as trains make more stops.

  7. Chemical Detection Architecture for a Subway System [video

    OpenAIRE

    Ignacio, Joselito; Center for Homeland Defense and Security Naval Postgraduate School

    2014-01-01

    This proposed system process aims to improve subway safety through better enabling the rapid detection and response to a chemical release in a subway system. The process is designed to be location-independent and generalized to most subway systems despite each system's unique characteristics.

  8. Random matrices and the New York City subway system

    OpenAIRE

    Jagannath, Aukosh; Trogdon, Thomas

    2017-01-01

    We analyze subway arrival times in the New York City subway system. We find regimes where the gaps between trains exhibit both (unitarily invariant) random matrix statistics and Poisson statistics. The departure from random matrix statistics is captured by the value of the Coulomb potential along the subway route. This departure becomes more pronounced as trains make more stops.

  9. FIRE

    International Nuclear Information System (INIS)

    Brtis, J.S.; Hausheer, T.G.

    1990-01-01

    FIRE, a microcomputer based program to assist engineers in reviewing and documenting the fire protection impact of design changes has been developed. Acting as an electronic consultant, FIRE is designed to work with an experienced nuclear system engineer, who may not have any detailed fire protection expertise. FIRE helps the engineer to decide if a modification might adversely affect the fire protection design of the station. Since its first development, FIRE has been customized to reflect the fire protection philosophy of the Commonwealth Edison Company. That program is in early production use. This paper discusses the FIRE program in light of its being a useful application of expert system technologies in the power industry

  10. Perverse incentives and invisible tradeoffs in subway construction in China: a case study of Hangzhou subway collapse

    NARCIS (Netherlands)

    J.F.M. Koppenjan (Joop); Y. Ma (Yongchi); M. de Jong (Martin); B. Xi (Bao)

    2010-01-01

    textabstractAbstract—Hangzhou subway collapse is the most serious subway construction disaster to date in China. In this article, the management and regulatory questions the collapse raised are focused and a case study of Hangzhou subway collapse is given. By regarding the contractual

  11. Study on evaluation of containment capability of glove box under fire accident (2)

    International Nuclear Information System (INIS)

    Abe, Hitoshi; Watanabe, Koji; Tashiro, Shinsuke; Uchiyama, Gunzo

    2007-11-01

    In the MOX fuel fabrication facility, MOX is required to be handled in glove box to sustain containment of MOX into the facility. In case of fire in the facility, the containment capability of glove box may be deteriorated by pyrolysis or combustion of the plastic materials as components of glove box caused by thermal stress from flame. The purpose of this study is to examine pyrolysis and combustion properties of the materials for applying them to quantitative evaluation method for the containment capability of glove box under fire. This report summarize experimental results about the properties under the air condition and investigation of evaluation model for estimating time-course of deteriorating containment capability of glove box under fire. (author)

  12. Fatal residential fire accidents in the municipality of Copenhagen, 1991-1996

    DEFF Research Database (Denmark)

    Leth, Peter Mygind; Gregersen, Markil Ebbe Gregers; Sabroe, Svend

    1998-01-01

    of the theoretical model in which the variables were part of a causal network. RESULTS: The following five variables seemed to be of most importance: (1) localization of the victim close to the source of ignition (OR = 11), (2) physical handicaps (OR = 5), (3) chronic alcoholism (OR = 7), (4) clothing fires (OR = 24...

  13. Chlorine Dioxide Fumigation of Subway Materials ...

    Science.gov (United States)

    Report This bench scale study observed that a six (6) log reduction in viable spores of a suitable B. anthracis surrogate can be obtained for subway infrastructure materials by ClO2 fumigation if the temperature is at or above 24 °C combined with RH greater than 75%. No six log reduction in viable spores was observed at realistic (winter) temperatures in a subway environment (11-13 °C and 70-80% RH) for periods of fumigation that are otherwise efficacious at 24 °C/ 75% RH.

  14. Bioaerosols in the Barcelona subway system.

    Science.gov (United States)

    Triadó-Margarit, X; Veillette, M; Duchaine, C; Talbot, M; Amato, F; Minguillón, M C; Martins, V; de Miguel, E; Casamayor, E O; Moreno, T

    2017-05-01

    Subway systems worldwide transport more than 100 million people daily; therefore, air quality on station platforms and inside trains is an important urban air pollution issue. We examined the microbiological composition and abundance in space and time of bioaerosols collected in the Barcelona subway system during a cold period. Quantitative PCR was used to quantify total bacteria, Aspergillus fumigatus, influenza A and B, and rhinoviruses. Multitag 454 pyrosequencing of the 16S rRNA gene was used to assess bacterial community composition and biodiversity. The results showed low bioaerosol concentrations regarding the targeted microorganisms, although the bacterial bioburden was rather high (10 4 bacteria/m 3 ). Airborne bacterial communities presented a high degree of overlap among the different subway environments sampled (inside trains, platforms, and lobbies) and were dominated by a few widespread taxa, with Methylobacterium being the most abundant genus. Human-related microbiota in sequence dataset and ascribed to potentially pathogenic bacteria were found in low proportion (maximum values below 2% of sequence readings) and evenly detected. Hence, no important biological exposure marker was detected in any of the sampled environments. Overall, we found that commuters are not the main source of bioaerosols in the Barcelona subway system. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Thermal Response of the 21-PWR Waste Package to a Fire Accident

    International Nuclear Information System (INIS)

    F.P. Faucher; H. Marr; M.J. Anderson

    2000-01-01

    The objective of this calculation is to evaluate the thermal response of the 21-PWR WP (pressurized water reactor waste package) to the regulatory fire event. The scope of this calculation is limited to the two-dimensional waste package temperature calculations to support the waste package design. The information provided by the sketches attached to this calculation (Attachment IV) is that of the potential design of the type of waste package considered in this calculation. The procedure AP-3.12Q.Calculations (Reference 1), and the Development Plan (Reference 24) are used to develop this calculation

  16. Identification of important phenomena under sodium fire accidents based on PIRT process with factor analysis in sodium-cooled fast reactor

    International Nuclear Information System (INIS)

    Aoyagi, Mitsuhiro; Uchibori, Akihiro; Kikuchi, Shin; Takata, Takashi; Ohno, Shuji; Ohshima, Hiroyuki

    2016-01-01

    The PIRT (Phenomena Identification and Ranking Table) process is an effective method to identify key phenomena involved in safety issues in nuclear power plants. The present PIRT process is aimed to validate sodium fire analysis codes. Because a sodium fire accident in sodium-cooled fast reactor (SFR) involves complex phenomena, various figures of merit (FOMs) could exist in this PIRT process. In addition, importance evaluation of phenomena for each FOM should be implemented in an objective manner under the PIRT process. This paper describes the methodology for specification of FOMs, identification of associated phenomena and importance evaluation of each associated phenomenon in order to complete a ranking table of important phenomena involved in a sodium fire accident in an SFR. The FOMs were specified through factor analysis in this PIRT process. Physical parameters to be quantified by a sodium fire analysis code were identified by considering concerns resulting from sodium fire in the factor analysis. Associated phenomena were identified through the element- and sequence-based phenomena analyses as is often conducted in PIRT processes. Importance of each associated phenomenon was evaluated by considering the sequence-based analysis of associated phenomena correlated with the FOMs. Then, we complete the ranking table through the factor and phenomenon analyses. (author)

  17. Health effects of a subway environment in healthy volunteers.

    Science.gov (United States)

    Klepczyńska Nyström, A; Svartengren, M; Grunewald, J; Pousette, C; Rödin, I; Lundin, A; Sköld, C M; Eklund, A; Larsson, B-M

    2010-08-01

    Environmental particle exposure, often estimated as the particulate mass of particles with a diameter subway environment. 20 healthy volunteers were exposed to a subway and a control environment for 2 h, followed by measurements of lung function and the inflammatory response in the lower airways (bronchoscopy) and in the peripheral blood. No cellular response was found in the airways after exposure to the subway environment. In the blood, we found a statistically significant increase in fibrinogen and regulatory T-cells expressing CD4/CD25/FOXP3. Subway and road tunnel environments have similar levels of PM(10) and PM(2.5), whilst the concentrations of ultrafine particles, nitrogen monoxide and dioxide are lower in the subway. Although no cellular response was detected, the findings indicate a biological response to the subway environment. Our studies show that using gravimetric estimates of ambient particulate air pollution alone may have clear limitations in health-risk assessment.

  18. Incidence of lung cancer among subway drivers in Stockholm.

    Science.gov (United States)

    Gustavsson, Per; Bigert, Carolina; Pollán, Marina

    2008-07-01

    Very high levels of airborne particles have been detected in the subway system in Stockholm. Subway particles are more toxic to DNA in cultured human lung cells than particles from ambient air. This cohort comprised all men in Stockholm County who were gainfully employed in 1970. They were followed for cancer incidence until 1989. Lung cancer cases were identified from the national cancer register. Subway drivers were identified from the census in 1970. The reference cohort comprised all transport and communication workers in Stockholm. There were nine cases of lung cancer among the subway drivers, giving a SIR of 0.82 (95% confidence interval 0.38-1.56). The lung cancer incidence was not increased among the subway drivers. The study gives some evidence against the hypothesis that subway particles would be more potent in inducing lung cancer than particles in ambient air. (c) 2008 Wiley-Liss, Inc.

  19. Dynamics of subway networks based on vehicles operation timetable

    Science.gov (United States)

    Xiao, Xue-mei; Jia, Li-min; Wang, Yan-hui

    2017-05-01

    In this paper, a subway network is represented as a dynamic, directed and weighted graph, in which vertices represent subway stations and weights of edges represent the number of vehicles passing through the edges by considering vehicles operation timetable. Meanwhile the definitions of static and dynamic metrics which can represent vertices' and edges' local and global attributes are proposed. Based on the model and metrics, standard deviation is further introduced to study the dynamic properties (heterogeneity and vulnerability) of subway networks. Through a detailed analysis of the Beijing subway network, we conclude that with the existing network structure, the heterogeneity and vulnerability of the Beijing subway network varies over time when the vehicle operation timetable is taken into consideration, and the distribution of edge weights affects the performance of the network. In other words, although the vehicles operation timetable is restrained by the physical structure of the network, it determines the performances and properties of the Beijing subway network.

  20. Cyclic subway networks are less risky in metropolises

    Science.gov (United States)

    Xiao, Ying; Zhang, Hai-Tao; Xu, Bowen; Zhu, Tao; Chen, Guanrong; Chen, Duxin

    2018-02-01

    Subways are crucial in modern transportation systems of metropolises. To quantitatively evaluate the potential risks of subway networks suffered from natural disasters or deliberate attacks, real data from seven Chinese subway systems are collected and their population distributions and anti-risk capabilities are analyzed. Counterintuitively, it is found that transfer stations with large numbers of connections are not the most crucial, but the stations and lines with large betweenness centrality are essential, if subway networks are being attacked. It is also found that cycles reduce such correlations due to the existence of alternative paths. To simulate the data-based observations, a network model is proposed to characterize the dynamics of subway systems under various intensities of attacks on stations and lines. This study sheds some light onto risk assessment of subway networks in metropolitan cities.

  1. A model for dispersion of contaminants in the subway environment

    Energy Technology Data Exchange (ETDEWEB)

    Coke, L. R.; Sanchez, J. G.; Policastro, A. J.

    2000-05-03

    Although subway ventilation has been studied extensively, very little has been published on dispersion of contaminants in the subway environment. This paper presents a model that predicts dispersion of contaminants in a complex subway system. It accounts for the combined transient effects of train motion, station airflows, train car air exchange rates, and source release properties. Results are presented for a range of typical subway scenarios. The effects of train piston action and train car air exchange are discussed. The model could also be applied to analyze the environmental impact of hazardous materials releases such as chemical and biological agents.

  2. Fuzzy fault tree assessment based on improved AHP for fire and explosion accidents for steel oil storage tanks.

    Science.gov (United States)

    Shi, Lei; Shuai, Jian; Xu, Kui

    2014-08-15

    Fire and explosion accidents of steel oil storage tanks (FEASOST) occur occasionally during the petroleum and chemical industry production and storage processes and often have devastating impact on lives, the environment and property. To contribute towards the development of a quantitative approach for assessing the occurrence probability of FEASOST, a fault tree of FEASOST is constructed that identifies various potential causes. Traditional fault tree analysis (FTA) can achieve quantitative evaluation if the failure data of all of the basic events (BEs) are available, which is almost impossible due to the lack of detailed data, as well as other uncertainties. This paper makes an attempt to perform FTA of FEASOST by a hybrid application between an expert elicitation based improved analysis hierarchy process (AHP) and fuzzy set theory, and the occurrence possibility of FEASOST is estimated for an oil depot in China. A comparison between statistical data and calculated data using fuzzy fault tree analysis (FFTA) based on traditional and improved AHP is also made. Sensitivity and importance analysis has been performed to identify the most crucial BEs leading to FEASOST that will provide insights into how managers should focus effective mitigation. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Comfort parameters - Ventilation of a subway wagon

    Science.gov (United States)

    Petr, Pavlíček; Ladislav, Tříska

    2017-09-01

    Research and development of a ventilation system is being carried out as a part of project TA04030774 of the Technology Agency of the Czech Republic. Name of the project is "Research and Development of Mass-optimized Components for Rail Vehicles". Problems being solved are development and testing of a new concept for ventilation systems for public transport vehicles. The main improvements should be a reduction of the mass of the whole system, easy installation and reduction of the noise of the ventilation system. This article is focused on the comfort parameters in a subway wagon (measurement and evaluation carried out on a function sample in accordance with the regulations). The input to the project is a ventilator hybrid casing for a subway wagon, which was manufactured and tested during the Ministry of Industry and Trade project TIP FR-TI3/449.

  4. Network structure of subway passenger flows

    Science.gov (United States)

    Xu, Q.; Mao, B. H.; Bai, Y.

    2016-03-01

    The results of transportation infrastructure network analyses have been used to analyze complex networks in a topological context. However, most modeling approaches, including those based on complex network theory, do not fully account for real-life traffic patterns and may provide an incomplete view of network functions. This study utilizes trip data obtained from the Beijing Subway System to characterize individual passenger movement patterns. A directed weighted passenger flow network was constructed from the subway infrastructure network topology by incorporating trip data. The passenger flow networks exhibit several properties that can be characterized by power-law distributions based on flow size, and log-logistic distributions based on the fraction of boarding and departing passengers. The study also characterizes the temporal patterns of in-transit and waiting passengers and provides a hierarchical clustering structure for passenger flows. This hierarchical flow organization varies in the spatial domain. Ten cluster groups were identified, indicating a hierarchical urban polycentric structure composed of large concentrated flows at urban activity centers. These empirical findings provide insights regarding urban human mobility patterns within a large subway network.

  5. Pilot survey of subway and bus stop noise levels.

    Science.gov (United States)

    Gershon, Robyn R M; Neitzel, Richard; Barrera, Marissa A; Akram, Muhammad

    2006-09-01

    Excessive noise exposure is a serious global urban health problem, adversely affecting millions of people. One often cited source of urban noise is mass transit, particularly subway systems. As a first step in determining risk within this context, we recently conducted an environmental survey of noise levels of the New York City transit system. Over 90 noise measurements were made using a sound level meter. Average and maximum noise levels were measured on subway platforms, and maximum levels were measured inside subway cars and at several bus stops for comparison purposes. The average noise level measured on the subway platforms was 86 +/- 4 dBA (decibel-A weighting). Maximum levels of 106, 112, and 89 dBA were measured on subway platforms, inside subway cars, and at bus stops, respectively. These results indicate that noise levels in subway and bus stop environments have the potential to exceed recommended exposure guidelines from the World Health Organization (WHO) and U.S. Environmental Protection Agency (EPA), given sufficient exposure duration. Risk reduction strategies following the standard hierarchy of control measures should be applied, where feasible, to reduce subway noise exposure.

  6. Effects of subways on urban form and structure

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T J

    1978-08-01

    A general equilibrium model was built which shows how the locations of employment and residences are related to alternative transportation systems. The model was applied to different size cities. The analysis suggests that the construction of a subway system will not necessarily result in the revitalization of the central business district or in the reversing of the trend toward suburbanization. Although land rent is generally higher in the city without subway systems than in the city with subway systems, the steeper rent gradient at the peripheries of the former, along with other findings, suggests that the rate of suburbanization of the city without subway systems is not significantly higher than of the city with subway systems.

  7. Reducing the impact of speed dispersion on subway corridor flow.

    Science.gov (United States)

    Qiao, Jing; Sun, Lishan; Liu, Xiaoming; Rong, Jian

    2017-11-01

    The rapid increase in the volume of subway passengers in Beijing has necessitated higher requirements for the safety and efficiency of subway corridors. Speed dispersion is an important factor that affects safety and efficiency. This paper aims to analyze the management control methods for reducing pedestrian speed dispersion in subways. The characteristics of the speed dispersion of pedestrian flow were analyzed according to field videos. The control measurements which were conducted by placing traffic signs, yellow marking, and guardrail were proposed to alleviate speed dispersion. The results showed that the methods of placing traffic signs, yellow marking, and a guardrail improved safety and efficiency for all four volumes of pedestrian traffic flow, and the best-performing control measurement was guardrails. Furthermore, guardrails' optimal position and design measurements were explored. The research findings provide a rationale for subway managers in optimizing pedestrian traffic flow in subway corridors. Copyright © 2017. Published by Elsevier Ltd.

  8. Characteristics and personal exposures of carbonyl compounds in the subway stations and in-subway trains of Shanghai, China.

    Science.gov (United States)

    Feng, Yanli; Mu, Cuicui; Zhai, Jinqing; Li, Jian; Zou, Ting

    2010-11-15

    Carbonyl compounds including their concentrations, potential sources, diurnal variations and personal exposure were investigated in six subway stations and in-subway trains in Shanghai in June 2008. The carbonyls were collected onto solid sorbent (Tenax TA) coated with pentafluorophenyl hydrazine (PFPH), followed by solvent extraction and gas chromatography (GC)/mass spectrometry (MS) analysis of the PFPH derivatives. The total carbonyl concentrations of in-subway train were about 1.4-2.5 times lower than in-subway stations. A significant correlation (R>0.5, psubway stations. The diurnal variations in both the subway station and in-subway train showed that the concentrations of most carbonyls were much higher in the morning rush hour than in other sampling periods. Additionally, pronounced diurnal variations of acetaldehyde concentration before and after the evening peak hour in the subway train suggested that passengers contributed to high acetaldehyde levels. The personal exposure showed that the underground subway stations were important microenvironment for exposure to formaldehyde and acetaldehyde. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Fire protection

    International Nuclear Information System (INIS)

    Janetzky, E.

    1980-01-01

    Safety and fire prevention measurements have to be treated like the activities developing, planning, construction and erection. Therefore it is necessary that these measurements have to be integrated into the activities mentioned above at an early stage in order to guarantee their effectiveness. With regard to fire accidents the statistics of the insurance companies concerned show that the damage caused increased in the last years mainly due to high concentration of material. Organization of fire prevention and fire fighting, reasons of fire break out, characteristics and behaviour of fire, smoke and fire detection, smoke and heat venting, fire extinguishers (portable and stationary), construction material in presence of fire, respiratory protection etc. will be discussed. (orig./RW)

  10. Models for fleet sizing and localization of fire-fighting for attendance to accidents in platforms; Modelos para dimensionamento de frota e localizacao de embarcacoes fire-fighting para atendimento a acidentes em plataformas

    Energy Technology Data Exchange (ETDEWEB)

    Medina, Afonso Celso; Brinati, Marco Antonio [Sao Paulo Univ., SP (Brazil). Escola Politecnica

    1996-12-31

    The increasing degree of use of maritime resources claims the establishment of a modern protection and assistance system to prevent and control maritime accidents. The usual safety systems for maritime accidents, generally, have the aid of specialized fleets in the attendance. This work presents models to determine the location and the profile of a specialized fleet for fire fighting, in order to guarantee the adequate attendance to expected accidents in a marine oil field. To modelling the problem, two means of analysis are considered: a deterministic model of integer programming and a probabilistic model. Considering the geographic location and the size of platforms as input data, the deterministic model establishes, among the available vessels, the fleet profile and location in order to minimize the fleet cost assuring the attendance to each platform within the standard requirements. The probabilistic model starts from a given solution for the fleet profile and vessel location and, by means of estimating the utilization factors of each vessel, proposes possible improvements in the fleet location, in order to maximize the probability of attending the accidents. A simulation model was elaborated to validate the results from the probabilistic model. The obtained results indicate the usefulness of every model, not only to a rational location problem solution, but also, for the analysis of the operational fleet performance. (author) 11 refs., 4 figs., 4 tabs.

  11. Calculation notes that support accident scenario and consequence of the in-tank fuel fire/deflageration

    International Nuclear Information System (INIS)

    Crowe, R.D. Westinghouse Hanford

    1996-01-01

    The purpose of this calculation note is to provide the basis for In-Tank Fuel fire/Deflageration consequence for the Tank Farm Safety Analysis Report (FSAR). Tank Fuel Fire/Deflageration scenario is developed and details and description of the analysis methods are provided

  12. Calculation notes that support accident scenario and consequence of the in-tank fuel fire/deflagration

    Energy Technology Data Exchange (ETDEWEB)

    Crowe, R.D.

    1996-09-27

    The purpose of this calculation note is to provide the basis for In-Tank Fuel Fire/Deflageration consequence for the Tank Farm Safety Analysis Report (FSAR). Tank Fuel Fire/Deflageration scenario is developed and details and description of the analysis methods are provided.

  13. Exposure to airborne particulate matter in the subway system.

    Science.gov (United States)

    Martins, Vânia; Moreno, Teresa; Minguillón, María Cruz; Amato, Fulvio; de Miguel, Eladio; Capdevila, Marta; Querol, Xavier

    2015-04-01

    The Barcelona subway system comprises eight subway lines, at different depths, with different tunnel dimensions, station designs and train frequencies. An extensive measurement campaign was performed in this subway system in order to characterise the airborne particulate matter (PM) measuring its concentration and investigating its variability, both inside trains and on platforms, in two different seasonal periods (warmer and colder), to better understand the main factors controlling it, and therefore the way to improve air quality. The majority of PM in the underground stations is generated within the subway system, due to abrasion and wear of rail tracks, wheels and braking pads caused during the motion of the trains. Substantial variation in average PM concentrations between underground stations was observed, which might be associated to different ventilation and air conditioning systems, characteristics/design of each station and variations in the train frequency. Average PM2.5 concentrations on the platforms in the subway operating hours ranged from 20 to 51 and from 41 to 91 μg m(-3) in the warmer and colder period, respectively, mainly related to the seasonal changes in the subway ventilation systems. The new subway lines with platform screen doors showed PM2.5 concentrations lower than those in the conventional system, which is probably attributable not only to the more advanced ventilation setup, but also to the lower train frequency and the design of the stations. PM concentrations inside the trains were generally lower than those on the platforms, which is attributable to the air conditioning systems operating inside the trains, which are equipped with air filters. This study allows the analysis and quantification of the impact of different ventilation settings on air quality, which provides an improvement on the knowledge for the general understanding and good management of air quality in the subway system. Copyright © 2014 The Authors. Published by

  14. Geotectonic variations of radon fields in the Tashkent subway stations

    International Nuclear Information System (INIS)

    Yafasov, A.Ya.; Akimov, V.A.

    2001-01-01

    The investigations into the radon fields in subsurface service rooms and platforms of the Tashkent subway arranged on the territories with different geotectonic characteristics were conducted by the use of the standard radiometers Alpha-GUARD PQ2000M and Gamma-TRACER (Germany), semiconductor spectrometers RATON (Uzbekistan). The effect of the tectonic factor on the radon fields formation in air of the subway was shown [ru

  15. SUBWAY POWER SYSTEMS WITH MODERN SEMICONDUCTOR CONVERTERS AND ENERGY STORAGE DEVICES

    Directory of Open Access Journals (Sweden)

    O.I. Kholod

    2013-02-01

    Full Text Available Five subway power systems, a traditional power system and power systems with an active rectifier and an energy storage device, are considered. Estimation of energy loss in the analyzed subway power systems circuits is made.

  16. Analysis of Subway Interior Noise at Peak Commuter Time.

    Science.gov (United States)

    Lee, Donguk; Kim, Gibbeum; Han, Woojae

    2017-07-01

    Although mass transit systems are convenient and efficient for urban people, little attention has been paid to the potential hearing hazard from their noise. The purpose of the current study was to measure and analyze levels of subway interior noise at peak commuter times and to provide information about commuters' daily dose of noise exposure. To measure the subway interior noise, nine subway lines inside Seoul (i.e., lines 1-9) and six lines surrounding the capital city area (i.e., Central, Bundang, Sinbundang, Incheon, Gyeongui, and Gyeongchun) were chosen. The noise was measured and recorded by a sound level meter for two-hour periods in the morning and evening. 1) In the LZeq analysis, the average noise level of all 15 lines was 72.78 dB; the maximum and minimum noise levels were 78.34 and 62.46 dB, respectively. The average noise level of the nine lines inside Seoul was 73.45 dB, which was 1.68-dB louder than that of the six lines surrounding the capital city area. 2) Based on the LZeq analysis of 33 measured frequencies, 12.5 Hz was the highest frequency and 20,000 Hz was the lowest. 3) There was no remarkable difference in the level of subway interior noise between morning and evening peak commuter times. We concluded that the level of subway interior noise was not loud enough for commuters to incur noise-induced hearing loss. Regardless, environmental noise control efforts in the subway system might be needed for commuters who take a subway every day.

  17. Plutonium fires; Incendies de plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Mestre, E.

    1959-06-23

    The author reports an information survey on accidents which occurred when handling plutonium. He first addresses accidents reported in documents. He indicates the circumstances and consequences of these accidents (explosion in glove boxes, fires of plutonium chips, plutonium fire followed by filter destruction, explosion during plutonium chip dissolution followed by chip fire). He describes hazards associated with plutonium fires: atmosphere and surface contamination, criticality. The author gives some advices to avoid plutonium fires. These advices concern electric installations, the use of flammable solvents, general cautions associated with plutonium handling, venting and filtration. He finally describes how to fight plutonium fires, and measures to be taken after the fire (staff contamination control, atmosphere control)

  18. [Protecting Safety During Dust Fires and Dust Explosions - The Example of the Formosa Fun Coast Water Park Accident].

    Science.gov (United States)

    Hsieh, Ming-Hong; Wu, Jia-Wun; Li, Ya-Cing; Tang, Jia-Suei; Hsieh, Chun-Chien

    2016-02-01

    This paper will explore the fire and explosion characteristics of cornstarch powder as well as strategies for protecting the safety of people who are involved a dust fire or dust explosion. We discuss the 5 elements of dust explosions and conduct tests to analyze the fire and explosion characteristics of differently colored powders (yellow, golden yellow, pink, purple, orange and green). The results show that, while all of the tested powders were difficult to ignite, low moisture content was associated with significantly greater risks of ignition and flame spread. We found the auto-ignition temperature (AIT) of air-borne cornstarch powder to be between 385°C and 405°C, with yellow-colored cornstarch powder showing the highest AIT and pink-colored cornstarch powder showing the lowest AIT. The volume resistivity of all powder samples was approximately 108 Ω.m, indicating that they were nonconductive. Lighters and cigarettes are effective ignition sources, as their lit temperatures are higher than the AIT of cornstarch powder. In order to better protect the safety of individuals at venues where cornstarch powder is released, explosion control measures such as explosion containment facilities, vents, and explosion suppression and isolation devices should be installed. Furthermore, employees that work at these venues should be better trained in explosion prevention and control measures. We hope this article is a reminder to the public to recognize the fire and explosion characteristics of flammable powders as well as the preventive and control measures for dust explosions.

  19. Adolescent Purchasing Behavior at McDonald's and Subway.

    Science.gov (United States)

    Lesser, Lenard I; Kayekjian, Karen C; Velasquez, Paz; Tseng, Chi-Hong; Brook, Robert H; Cohen, Deborah A

    2013-10-01

    To assess whether adolescents purchasing food at a restaurant marketed as "healthy" (Subway) purchase fewer calories than at a competing chain (McDonald's). We studied 97 adolescents who purchased a meal at both restaurants on different days, using each participant as his or her control. We compared the difference in calories purchased by adolescents at McDonald's and Subway in a diverse area of Los Angeles, CA. Adolescents purchased an average of 1,038 calories (standard error of the mean [SEM]: 41) at McDonald's and 955 calories (SEM 39) at Subway. The difference of 83 calories (95% confidence interval [CI]: -20 to 186) was not statistically significant (p = .11). At McDonald's, participants purchased significantly more calories from drinks (151 vs. 61, p McDonald's vs. 35 at Subway, p McDonald's (.15 vs. .57 cups, p McDonald's. Although Subway meals had more vegetables, meals from both restaurants are likely to contribute to overeating. Copyright © 2013 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  20. Factors associated with suicide ideation among subway drivers in Korea.

    Science.gov (United States)

    Byun, Junsu; Kim, Hyoung-Ryoul; Lee, Hye-Eun; Kim, Se-Eun; Lee, Jongin

    2016-01-01

    There were several suicide events of subway drivers in Korea. The aim of this study is to explore work-related factors associated with suicide ideation among subway drivers. We analyzed data from 980 male subway drivers. A section of the Korean version of the Composite International Diagnostic Interview (K-CIDI 2.1) was administered by trained interviewers to judge whether a driver has suicide ideation and to diagnose psychiatric disorders. A questionnaire was also administered to collect data on sociodemographic characteristics, work environments, occupational stress, person under train (PUT) experience, and work-related problems. Occupational stress was examined by using the Korean Occupational Stress Scale (KOSS). Logistic regression was applied to evaluate the association between work-related factors and suicide ideation among subway drivers. Regarding work-related problems, conflict with passengers and sudden stops due to the emergency bell were significantly associated with suicide ideation. MDD, PTSD, and panic disorder were strongly associated with suicide ideation. In the analysis of occupational stress, insufficient job control (OR 2.34) and lack of reward (OR 2.52) were associated with suicide ideation even after being adjusted for psychiatric disorders and other work-related factors. Insufficient job control and lack of reward were associated with suicide ideation among subway drivers. Strategies for drivers to have autonomy while working and to achieve effort-reward balance should be implemented. Furthermore, drivers who have experienced negative work-related problems should be managed appropriately.

  1. The Effectiveness of Behavior Therapy and Symptoms of PTSD in Trauma Survivors Fire Accident in Industrial Pole of Shahid Babaie City Shazand

    Directory of Open Access Journals (Sweden)

    M. Sadeghi

    2015-05-01

    Full Text Available Background: The aim of this present study was to the effectiveness of behavior therapy in the treatment of posttraumatic stress disorder symptoms and general health of in Trauma Survivors Fire Accident in Industrial Pole of Shahid Babaie City Shazand in 1387. Methods: The present plan study of experimental design with pre - and post - test method after the test. community study all the survivors industrial hub of fire martyr Babaie city shazand township to approach the census initial screening . 111 people , including the study sample of adults in post - traumatic stress disorder after the damage to the non - random sampling method available and chosen at random in 2 men's and 6 women's group exposure. at the beginning of the Check - List post - traumatic stress disorder , and public health , then 7 completed training session behavioral therapy group manner, and again in the final session by evaluated questionnaires. Results: Do intervention in increasing public health survivors and reduce the symptoms of post - traumatic stress disorder, anxiety , depression , the signs of physical and social function is effective survivors (p<0/0001. Conclusion: Psychological treatments to reduce the symptoms of post- traumatic stress disorder is effective in the survivors.

  2. The role of forensic anthropology in the examination of the Daegu subway disaster (2003, Korea).

    Science.gov (United States)

    Park, Dae-Kyoon; Park, Kyung-Ho; Ko, Jeong-Sik; Kim, Yi-Suk; Chung, Nak-Eun; Ahn, Yong-Woo; Han, Seung-Ho

    2009-05-01

    Meticulous recovery of victims in the Daegu subway disaster was possible, because charred and fragmented victims were left in situ. Because bodies were piled one over another within the train, appropriate methodology during the recovery was critical to identifying the victims. The disaster area was thoroughly documented with notes, photographs, and schematic drawings of the various locations. The recovery team, comprising two medical examiners and one forensic anthropologist, decided when charred body parts and cremated bones were linked to the same individual based on the anatomy and forensic anthropological examination. Without these recovery procedures, it would not have been possible to efficiently harvest representative DNA sample from most of the victims' body parts. After the entire process of identification, 136 victims were positively identified, and six victims remained unidentified. This study supports the crucial role of forensic anthropologists in the recovery of victims, especially in fire scenes.

  3. Windscale fire

    International Nuclear Information System (INIS)

    Auxier, J.A.

    1986-01-01

    A graphite fire in the Windscale No. 1 reactor occurred during the period October 8-12, 1957. The Windscale reactors were located on a coastal plain in northwest England and were used to produce plutonium. A great wealth of information was gathered on the causes, handling, decontamination, and environmental effects of reactor accidents. Topics of discussion include: the cause of the fire; handling of the incident; radiation doses to the population; and radiation effects on the population

  4. Route Choice in Subway Station during Morning Peak Hours: A Case of Guangzhou Subway

    Directory of Open Access Journals (Sweden)

    Jie Xu

    2015-01-01

    Full Text Available This paper is aimed at crowding phenomenon in the subway. As passengers are inclined to choose the route with minimum disutility, we put forward a route choice model which is constructed to achieve minimum objective function of feasibility for the optimal solution. Meanwhile we set passenger volume threshold values according to capacity of facilities. In the case of actual capacity exceeding the threshold, the decision node of constrained route will be selected; computing procedure about searching decision points will be presented. Then we should set rational restrictions at the decision node of the minimum utility function route to prevent too many passengers’ access to platform. Through certification, this series of methods can effectively ensure the safety of the station efficient operation.

  5. Geotectonic variations of radon fields in Tashkent subway stations

    International Nuclear Information System (INIS)

    Yafasov, A.Ya.; Akimov, V.A.

    2001-01-01

    The anomalies of radon fields in the air of stations of Tashkent subway were investigated. These stations are located in areas with different tectonic characteristics. The influence of tectonic anomalies on formation and variations of radon fields in the environment was shown. (author)

  6. Health effects of a subway environment in mild asthmatic volunteers.

    Science.gov (United States)

    Klepczyńska-Nyström, Anna; Larsson, Britt-Marie; Grunewald, Johan; Pousette, Charlotte; Lundin, Anders; Eklund, Anders; Svartengren, Magnus

    2012-01-01

    Particle exposure is known to have negative health effects. In Stockholm the environment in the subway has been reported to have higher particle exposure levels, measured as PM(2.5) and PM(10), than roads with intense traffic in the inner city area. We have recently shown that healthy volunteers exposed to subway environment had statistically significant increase of fibrinogen and CD4 cells expressing regulatory T-cell marker CD25(bright)/FOXP3 in blood. The aim of the present study was to find out whether a more vulnerable population, asthmatics, would demonstrate similar or other changes in the lungs or in the peripheral blood. Sixteen mild asthmatics were exposed to a subway and a control environment for 2 h while being monitored by measurements of lung function, and inflammatory response in the lower airways evaluated by bronchoscopy and in peripheral blood. An attempt to standardize the exposures was done, by letting the volunteers alternate 15 min intervals of moderate exercise on a bicycle ergometer with 15 min of rest. We found a statistically significant increased frequency of CD4 cells expressing T-cell activation marker CD25 in bronchoalveolar lavage fluid, but no significant increase of regulatory T-cells in blood as was found in healthy volunteers. Our study shows that airway inflammatory responses after exposure in subway environment differ between asthmatic and healthy humans. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Investigation of Magnetic Field in the Subway Station

    Directory of Open Access Journals (Sweden)

    Ctibor Henzl

    2006-01-01

    Full Text Available Paper deals with computing of magnetic field in the rails surroundings of subway (underground. The calculation of field is made by using of an analytical method in Excel VBA. There is also used commercial FEM software ANSYS and finite element method. Output results of the both methods are finally compared.

  8. Saturday Subway Ride: A Report on the Initial Tryout.

    Science.gov (United States)

    Quilling, Mary R.; And Others

    "Saturday Subway Ride," a program designed to teach pupils creative thinking techniques and positive attitudes toward creative ideas, is a 92-page workbook in a story-exercise format. Secondary objectives for the product include improving verbal fluency and creative writing. Three classrooms 61 sixth graders and 34 fifth graders at two…

  9. Choosing TBM for Tabriz Subway using Multi Criteria Method

    DEFF Research Database (Denmark)

    Edalat, Kamaladdin; Vahdatirad, Mohammadjavad; Ghodrat, Hadi

    2010-01-01

    in diameter and in other words becoming more difficult to realize. Tabriz-one of the big cities in northern west of Iran has four subway lines which are under con-struction or investigation. The phase1 design of Tabriz urban railway line 2 (TURL2) has completely been done. Method statement of this line...

  10. Oxidative potential of subway PM2.5

    Science.gov (United States)

    Moreno, Teresa; Kelly, Frank J.; Dunster, Chrissi; Oliete, Ana; Martins, Vânia; Reche, Cristina; Minguillón, Maria Cruz; Amato, Fulvio; Capdevila, Marta; de Miguel, Eladio; Querol, Xavier

    2017-01-01

    Air quality in subway systems is of interest not only because particulate matter (PM) concentrations can be high, but also because of the peculiarly metalliferous chemical character of the particles, most of which differ radically from those of outdoor ambient air. We report on the oxidative potential (OP) of PM2.5 samples collected in the Barcelona subway system in different types of stations. The PM chemical composition of these samples showed typically high concentrations of Fe, Total Carbon, Ba, Cu, Mn, Zn and Cr sourced from rail tracks, wheels, catenaries, brake pads and pantographs. Two toxicological indicators of oxidative activity, ascorbic acid (AA) oxidation (expressed as OPAA μg-1 or OPAA m-3) and glutathione (GSH) oxidation (expressed as OPGSH μg-1 or OPGSH m-3), showed low OP for all samples (compared with outdoor air) but considerable variation between stations (0.9-2.4 OPAA μg-1; 0.4-1.9 OPGSH μg-1). Results indicate that subway PM toxicity is not related to variations in PM2.5 concentrations produced by ventilation changes, tunnel works, or station design, but may be affected more by the presence of metallic trace elements such as Cu and Sb sourced from brakes and pantographs. The OP assays employed do not reveal toxic effects from the highly ferruginous component present in subway dust.

  11. Domino effect in chemical accidents: main features and accident sequences.

    Science.gov (United States)

    Darbra, R M; Palacios, Adriana; Casal, Joaquim

    2010-11-15

    The main features of domino accidents in process/storage plants and in the transportation of hazardous materials were studied through an analysis of 225 accidents involving this effect. Data on these accidents, which occurred after 1961, were taken from several sources. Aspects analyzed included the accident scenario, the type of accident, the materials involved, the causes and consequences and the most common accident sequences. The analysis showed that the most frequent causes are external events (31%) and mechanical failure (29%). Storage areas (35%) and process plants (28%) are by far the most common settings for domino accidents. Eighty-nine per cent of the accidents involved flammable materials, the most frequent of which was LPG. The domino effect sequences were analyzed using relative probability event trees. The most frequent sequences were explosion→fire (27.6%), fire→explosion (27.5%) and fire→fire (17.8%). Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Accidents - Chernobyl accident; Accidents - accident de Tchernobyl

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This file is devoted to the Chernobyl accident. It is divided in four parts. The first part concerns the accident itself and its technical management. The second part is relative to the radiation doses and the different contaminations. The third part reports the sanitary effects, the determinists ones and the stochastic ones. The fourth and last part relates the consequences for the other European countries with the case of France. Through the different parts a point is tackled with the measures taken after the accident by the other countries to manage an accident, the cooperation between the different countries and the groups of research and studies about the reactors safety, and also with the international medical cooperation, specially for the children, everything in relation with the Chernobyl accident. (N.C.)

  13. What Makes Urban Transportation Efficient? Evidence from Subway Transfer Stations in Korea

    Directory of Open Access Journals (Sweden)

    Changhee Kim

    2017-11-01

    Full Text Available Subway stations have been proliferating underneath cosmopolitan metropolises with subway lines forming complex webs connected in strategic transfer stations. The efficiency of the subway system thus heavily weighs on the efficiency at these transfer stations. However, few studies have been conducted on transfer efficiency at transfer stations due to the complexities involved. As the first study of its kind in the subway context, we analyze the transfer efficiency of the subway transfer stations in Seoul, one of the megacities in the world, and demonstrate how transfer efficiency can be analyzed using bootstrap-based DEA technique. Based on the results, we discuss the reasons behind the inefficiency of subway transfer stations and possible ways to improve them into efficient decision-making units.

  14. [To the issue on the optimization and regulation of microclimate in the subway trains and stations].

    Science.gov (United States)

    Leksin, A G; Beresneva, T G; Kaptsov, V A; Korotich, L P; Evlampieva, M N; Timoshenkova, E V

    2014-01-01

    There is presented an overview of currently existing regulatory framework governing the parameters of the microclimate in the salons of subway passenger cars and stations. Analysis of the normative documents indicated that they contain very incomplete, contradictory, often unfounded information about the parameters of microclimate parameters in salons of subway rolling stock. Also, there are no clear cut hygienically-sound requirements for the work of imposed on the rolling stock subway systems provide microclimate, including new systems for air conditioning and disinfection.

  15. Biological effects of particles from the paris subway system.

    Science.gov (United States)

    Bachoual, Rafik; Boczkowski, Jorge; Goven, Delphine; Amara, Nadia; Tabet, Lyes; On, Dinhill; Leçon-Malas, Véronique; Aubier, Michel; Lanone, Sophie

    2007-10-01

    Particulate matter (PM) from atmospheric pollution can easily deposit in the lungs and induce recruitment of inflammatory cells, a source of inflammatory cytokines, oxidants, and matrix metalloproteases (MMPs), which are important players in lung structural homeostasis. In many large cities, the subway system is a potent source of PM emission, but little is known about the biological effects of PM from this source. We performed a comprehensive study to evaluate the biological effects of PM sampled at two sites (RER and Metro) in the Paris subway system. Murine macrophages (RAW 264.7) and C57Bl/6 mice, respectively, were exposed to 0.01-10 microg/cm2 and 5-100 microg/mouse subway PM or reference materials [carbon black (CB), titanium dioxide (TiO2), or diesel exhaust particles (DEPs)]. We analyzed cell viability, production of cellular and lung proinflammatory cytokines [tumor necrosis factor alpha (TNFalpha), macrophage inflammatory protein (MIP-2), KC (the murin analog of interleukin-8), and granulocyte macrophage-colony stimulating factor (GM-CSF)], and mRNA or protein expression of MMP-2, -9, and -12 and heme oxygenase-1 (HO-1). Deferoxamine and polymixin B were used to evaluate the roles of iron and endotoxin, respectively. Noncytotoxic concentrations of subway PM (but not CB, TiO2, or DEPs) induced a time- and dose-dependent increase in TNFalpha and MIP-2 production by RAW 264.7 cells, in a manner involving, at least in part, PM iron content (34% inhibition of TNF production 8 h after stimulation of RAW 264.7 cells with 10 microg/cm2 RER particles pretreated with deferoxamine). Similar increased cytokine production was transiently observed in vivo in mice and was accompanied by an increased neutrophil cellularity of bronchoalveolar lavage (84.83+/-0.98% of polymorphonuclear neutrophils for RER-treated mice after 24 h vs 7.33+/-0.99% for vehicle-treated animals). Subway PM induced an increased expression of MMP-12 and HO-1 both in vitro and in vivo. PM from the

  16. Optimal Locations of Bus Stops Connecting Subways near Urban Intersections

    Directory of Open Access Journals (Sweden)

    Yuan Cui

    2015-01-01

    Full Text Available Unsuitable locations of bus stops which provide feeder transportation connecting subways near urban intersections usually lead to the low efficiency of public transport and level of passenger service. A multiobjective optimization model to distribute such stop locations is proposed to attain the shortest total walk distance of passengers and minimum delay time of cars through intersections and travel time of buses. The Pareto frontier and optimal solutions for the proposed model are given by the distance-based and enumerative methods. The Xizhimen bus stop is selected to implement case studies for verifying the validity of the proposed model. The analysis of sensitivity on possible solutions is also carried out in the case studies. The results show that the proposed model is capable of optimizing the locations of bus stops connecting subways near intersections and helpful to improve the level of passengers service and operational efficiency of public transportation.

  17. Marketingové strategie řetězce Subway

    OpenAIRE

    Nguyen, Huu Tung

    2015-01-01

    This Bachelor's Thesis examines the marketing strategy of the SUBWAY restaurant chain, its market positioning, segmentation and targeting strategies and comparison between national and local marketing tactics. The aim of the Bachelor's Thesis is to make suggestions beneficial to improvements in brand awareness and growth of the company. Thesis is divided into two sections of theoretical part and practical part. In the theoretical part of the Bachelor's thesis discusses about marketing basis, ...

  18. The Improvement on the Xinjiekou Subway Transfer Channel of Nanjing

    Science.gov (United States)

    Xu, X. D.; Zheng, C. J.

    The subway, which is an effective way to alleviate the traffic congestion, has gradually been constructed in many cities. With the completion of the construction, the transfer station will become the factor that affects the efficiency of the whole transport network. Based on investigation and analysis of the present situation of the passenger flow, the essay will make a prediction with the multiple linear regression and put forward two kinds of transfer channel improvement schemes for xinjiekou transfer station.

  19. Coordination between Subway and Urban Space: A Networked Approach

    Directory of Open Access Journals (Sweden)

    Lei Mao

    2014-05-01

    Full Text Available This paper selects Changsha as a case study and constructs the models of the subway network and the urban spatial network by using planning data. In the network models, the districts of Changsha are regarded as nodes and the connections between each pair of districts are regarded as edges. The method is based on quantitative analysis of the node weights and the edge weights, which are defined in the complex network theory. And the structures of subway and urban space are visualized in the form of networks. Then, through analyzing the discrepancy coefficients of the corresponding nodes and edges, the paper carries out a comparison between the two networks to evaluate the coordination. The results indicate that only 21.4% of districts and 13.2% of district connections have a rational coordination. Finally, the strategies are put forward for optimization, which suggest adjusting subway transit density, regulating land-use intensity and planning new mass transits for the uncoordinated parts.

  20. Formation and alteration of airborne particles in the subway environment.

    Science.gov (United States)

    Moreno, T; Querol, X; Martins, V; Minguillón, M C; Reche, C; Ku, L H; Eun, H R; Ahn, K H; Capdevila, M; de Miguel, E

    2017-01-25

    Most particles in the rail subway environment are sub-micron sized ferruginous flakes and splinters generated mechanically by frictional wear of brake pads, wheels and rails. To better understand the mechanisms of formation and the alteration processes affecting inhalable particles in subways, PM samples (1-2.5 μm and 2.5-10 μm) were collected in the Barcelona Metro and then studied under a scanning electron microscope. Most particles in these samples are hematitic (up to 88%), with relatively minor amounts of mineral matter (up to 9%) and sulphates (up to 5%). Detailed microscopy (using back scattered and TEM-DRX imaging) reveals how many of the metallic particles comprise the metallic Fe nucleus surrounded by hematite (Fe 2 O 3 ) and a coating of sulphate and chloride salts mixed with mineral matter (including Ca-carbonates, clay minerals and quartz). These observations record the emission of fine to ultrafine FePM by frictional wear at elevated temperatures that promote rapid partial (or complete) oxidation of the native metal. Water condensing on the PM surface during cooling leads to the adsorption of inorganic mineral particles that coat the iron oxide. The distinctively layered polymineralic structure that results from these processes is peculiar to particles generated in the subway environment and very different from PM typically inhaled outdoors.

  1. Assessment of noise exposure during commuting in the Madrid subway.

    Science.gov (United States)

    Tabacchi, M; Pavón, I; Ausejo, M; Asensio, C; Recuero, M

    2011-09-01

    Because noise-induced hearing impairment is the result not only of occupational noise exposure but also of total daily noise exposure, it is important to take the non-occupational exposure of individuals (during commuting to and from their jobs, at home, and during recreational activities) into account. Mass transit is one of the main contributors to non-occupational noise exposure. We developed a new methodology to estimate a representative commuting noise exposure. The methodology was put into practice for the Madrid subway because of all Spanish subway systems it covers the highest percentage of worker journeys (22.6%). The results of the application highlight that, for Madrid subway passengers, noise exposure level normalized to a nominal 8 hr (L(Ex,8h-cj) ) depends strongly on the type of train, the presence of squealing noise, and the public address audio system, ranging from 68.6 dBA to 72.8 dBA. These values play an important role in a more complete evaluation of a relationship between noise dose and worker health response.

  2. Predicting Short-Term Subway Ridership and Prioritizing Its Influential Factors Using Gradient Boosting Decision Trees

    Directory of Open Access Journals (Sweden)

    Chuan Ding

    2016-10-01

    Full Text Available Understanding the relationship between short-term subway ridership and its influential factors is crucial to improving the accuracy of short-term subway ridership prediction. Although there has been a growing body of studies on short-term ridership prediction approaches, limited effort is made to investigate the short-term subway ridership prediction considering bus transfer activities and temporal features. To fill this gap, a relatively recent data mining approach called gradient boosting decision trees (GBDT is applied to short-term subway ridership prediction and used to capture the associations with the independent variables. Taking three subway stations in Beijing as the cases, the short-term subway ridership and alighting passengers from its adjacent bus stops are obtained based on transit smart card data. To optimize the model performance with different combinations of regularization parameters, a series of GBDT models are built with various learning rates and tree complexities by fitting a maximum of trees. The optimal model performance confirms that the gradient boosting approach can incorporate different types of predictors, fit complex nonlinear relationships, and automatically handle the multicollinearity effect with high accuracy. In contrast to other machine learning methods—or “black-box” procedures—the GBDT model can identify and rank the relative influences of bus transfer activities and temporal features on short-term subway ridership. These findings suggest that the GBDT model has considerable advantages in improving short-term subway ridership prediction in a multimodal public transportation system.

  3. The Usefulness of Tactual Maps of the New York City Subway System.

    Science.gov (United States)

    Luxton, K.; And Others

    1994-01-01

    Sixteen people with blindness or visual impairments used three different types of tactual maps of the New York City subway system presenting information at three levels of specificity. Results indicated that the tactual maps improved participants' attitudes toward the subway and benefited blind as well as low vision participants. (Author/DB)

  4. [Distribution of airborne fungi, particulate matter and carbon dioxide in Seoul metropolitan subway stations].

    Science.gov (United States)

    Kim, Ki Youn; Park, Jae Beom; Kim, Chi Nyon; Lee, Kyung Jong

    2006-07-01

    The aims of this study were to examine the level of airborne fungi and environmental factors in Seoul metropolitan subway stations and to provide fundamental data to protect the health of subway workers and passengers. The field survey was performed from November in 2004 to February in 2005. A total 22 subway stations located at Seoul subway lines 1-4 were randomly selected. The measurement points were subway workers' activity areas (station office, bedroom, ticket office and driver's seat) and the passengers' activity areas (station precincts, inside train and platform). Air sampling for collecting airborne fungi was carried out using a one-stage cascade impactor. The PM and CO2 were measured using an electronic direct recorder and detecting tube, respectively. In the activity areas of the subway workers and passengers, the mean concentrations of airborne fungi were relatively higher in the workers' bedroom and station precinct whereas the concentration of particulate matter, PM10 and PM2.5, were relatively higher in the platform, inside the train and driver's seat than in the other activity areas. There was no significant difference in the concentration of airborne fungi between the underground and ground activity areas of the subway. The mean PM10 and PM2.5 concentration in the platform located at underground was significantly higher than that of the ground (psubway line 1-4 were not serious enough to cause respiratory disease in subway workers and passengers. This indicates that there is little correlation between airborne fungi and particulate matter.

  5. Public Health Lessons Learned From Analysis of New York City Subway Injuries

    Science.gov (United States)

    Guth, Amber A.; O’Neill, Andrea; Pachter, H. Leon; Diflo, Thomas

    2006-01-01

    Serious subway injuries are devastating to their young victims and have high rates of mortality and amputation. We identified the urban population at greatest risk for subway injuries and investigated the influence of local economies on injury rates. We propose using changes in social conditions as a “trigger” for increased vigilance and protective measures at times of higher risk. PMID:16449596

  6. Fire safety

    International Nuclear Information System (INIS)

    Keski-Rahkonen, O.; Bjoerkman, J.; Hostikka, S.; Mangs, J.; Huhtanen, R.; Palmen, H.; Salminen, A.; Turtola, A.

    1998-01-01

    According to experience and probabilistic risk assessments, fires present a significant hazard in a nuclear power plant. Fires may be initial events for accidents or affect safety systems planned to prevent accidents and to mitigate their consequences. The project consists of theoretical work, experiments and simulations aiming to increase the fire safety at nuclear power plants. The project has four target areas: (1) to produce validated models for numerical simulation programmes, (2) to produce new information on the behavior of equipment in case of fire, (3) to study applicability of new active fire protecting systems in nuclear power plants, and (4) to obtain quantitative knowledge of ignitions induced by important electric devices in nuclear power plants. These topics have been solved mainly experimentally, but modelling at different level is used to interpret experimental data, and to allow easy generalisation and engineering use of the obtained data. Numerical fire simulation has concentrated in comparison of CFD modelling of room fires, and fire spreading on cables on experimental data. So far the success has been good to fair. A simple analytical and numerical model has been developed for fire effluents spreading beyond the room of origin in mechanically strongly ventilated compartments. For behaviour of equipment in fire several full scale and scaled down calorimetric experiments were carried out on electronic cabinets, as well as on horizontal and vertical cable trays. These were carried out to supply material for CFD numerical simulation code validation. Several analytical models were developed and validated against obtained experimental results to allow quick calculations for PSA estimates as well as inter- and extrapolations to slightly different objects. Response times of different commercial fire detectors were determined for different types of smoke, especially emanating from smoldering and flaming cables to facilitate selection of proper detector

  7. Fire fighting at Chernobyl and fire protection at UK nuclear power stations

    International Nuclear Information System (INIS)

    Bindon, F.J.L.

    1987-01-01

    The fire fighting measures undertaken by the fire crews at the Chernobyl reactor accident are described. This information highlights the need to develop engineering equipment which will give a far greater degree of personnel protection to fire crews and others in radiological accidents. The British position on fire protection at nuclear power stations is outlined. The general levels of radiation exposure which would be used as a guide to persons in the vicinity of a radiation accident are also given. (UK)

  8. Improved social force model based on exit selection for microscopic pedestrian simulation in subway station

    Institute of Scientific and Technical Information of China (English)

    郑勋; 李海鹰; 孟令云; 许心越; 陈旭

    2015-01-01

    An improved social force model based on exit selection is proposed to simulate pedestrians’ microscopic behaviors in subway station. The modification lies in considering three factors of spatial distance, occupant density and exit width. In addition, the problem of pedestrians selecting exit frequently is solved as follows: not changing to other exits in the affected area of one exit, using the probability of remaining preceding exit and invoking function of exit selection after several simulation steps. Pedestrians in subway station have some special characteristics, such as explicit destinations, different familiarities with subway station. Finally, Beijing Zoo Subway Station is taken as an example and the feasibility of the model results is verified through the comparison of the actual data and simulation data. The simulation results show that the improved model can depict the microscopic behaviors of pedestrians in subway station.

  9. [Study on transition metals in airborne particulate matter in Shanghai city's subway].

    Science.gov (United States)

    Bao, Liang-Man; Lei, Qian-Tao; Tan, Ming-Guang; Li, Xiao-Lin; Zhang, Gui-Lin; Liu, Wei; Li, Yan

    2014-06-01

    PM10 and PM2.5 aerosol particle samples were collected at a subway station in Shanghai and their morphology, chemical composition and transition metal species were studied. The mass concentrations of PM10 and PM2.5 inside the subway station were significantly higher than those measured in aboveground ambient air. The PM levels inside subway were much higher than the state control limit. The aerosol composition in the metro station was quite different from that of the aboveground urban particles. Concentrations of Fe, Mn and Cr were higher than the averages of aboveground urban air particles by factors of 8, 2, and 2, respectively, showing a substantial enrichment in subway. Scanning electron microscope (SEM) analysis showed that the subway particles had flat surfaces in combination with parallel scratches and sharp edges and looked like metal sheets or flakes. Furthermore, analysis of the atomic composition of typical subway particles by energy dispersive X-Ray (EDX) spectroscopy showed that oxygen and iron dominated the mass of the particles. The X-ray absorption near-edge structure (XANES) spectroscopy results showed that a fraction (> 26%) of the total iron in the PM10 was in the form of pure Fe, while in the street particles Fe(III) was shown to be a significant fraction of the total iron. The work demonstrated that the underground subway stations in Shanghai were an important microenvironment for exposure to transition metal aerosol for the people taking subway train for commuting every day and those who work in the subway stations, and the metal particle exposure for people in the subway station should not be ignored.

  10. Indoor-air microbiome in an urban subway network: diversity and dynamics.

    Science.gov (United States)

    Leung, Marcus H Y; Wilkins, David; Li, Ellen K T; Kong, Fred K F; Lee, Patrick K H

    2014-11-01

    Subway systems are indispensable for urban societies, but microbiological characteristics of subway aerosols are relatively unknown. Previous studies investigating microbial compositions in subways employed methodologies that underestimated the diversity of microbial exposure for commuters, with little focus on factors governing subway air microbiology, which may have public health implications. Here, a culture-independent approach unraveling the bacterial diversity within the urban subway network in Hong Kong is presented. Aerosol samples from multiple subway lines and outdoor locations were collected. Targeting the 16S rRNA gene V4 region, extensive taxonomic diversity was found, with the most common bacterial genera in the subway environment among those associated with skin. Overall, subway lines harbored different phylogenetic communities based on α- and β-diversity comparisons, and closer inspection suggests that each community within a line is dependent on architectural characteristics, nearby outdoor microbiomes, and connectedness with other lines. Microbial diversities and assemblages also varied depending on the day sampled, as well as the time of day, and changes in microbial communities between peak and nonpeak commuting hours were attributed largely to increases in skin-associated genera in peak samples. Microbial diversities within the subway were influenced by temperature and relative humidity, while carbon dioxide levels showed a positive correlation with abundances of commuter-associated genera. This Hong Kong data set and communities from previous studies conducted in the United States formed distinct community clusters, indicating that additional work is required to unravel the mechanisms that shape subway microbiomes around the globe. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  11. Characterization of airborne bacteria at an underground subway station.

    Science.gov (United States)

    Dybwad, Marius; Granum, Per Einar; Bruheim, Per; Blatny, Janet Martha

    2012-03-01

    The reliable detection of airborne biological threat agents depends on several factors, including the performance criteria of the detector and its operational environment. One step in improving the detector's performance is to increase our knowledge of the biological aerosol background in potential operational environments. Subway stations are enclosed public environments, which may be regarded as potential targets for incidents involving biological threat agents. In this study, the airborne bacterial community at a subway station in Norway was characterized (concentration level, diversity, and virulence- and survival-associated properties). In addition, a SASS 3100 high-volume air sampler and a matrix-assisted laser desorption ionization-time of flight mass spectrometry-based isolate screening procedure was used for these studies. The daytime level of airborne bacteria at the station was higher than the nighttime and outdoor levels, and the relative bacterial spore number was higher in outdoor air than at the station. The bacterial content, particle concentration, and size distribution were stable within each environment throughout the study (May to September 2010). The majority of the airborne bacteria belonged to the genera Bacillus, Micrococcus, and Staphylococcus, but a total of 37 different genera were identified in the air. These results suggest that anthropogenic sources are major contributors to airborne bacteria at subway stations and that such airborne communities could harbor virulence- and survival-associated properties of potential relevance for biological detection and surveillance, as well as for public health. Our findings also contribute to the development of realistic testing and evaluation schemes for biological detection/surveillance systems by providing information that can be used to mimic real-life operational airborne environments in controlled aerosol test chambers.

  12. Characterization of Airborne Bacteria at an Underground Subway Station

    Science.gov (United States)

    Dybwad, Marius; Granum, Per Einar; Bruheim, Per

    2012-01-01

    The reliable detection of airborne biological threat agents depends on several factors, including the performance criteria of the detector and its operational environment. One step in improving the detector's performance is to increase our knowledge of the biological aerosol background in potential operational environments. Subway stations are enclosed public environments, which may be regarded as potential targets for incidents involving biological threat agents. In this study, the airborne bacterial community at a subway station in Norway was characterized (concentration level, diversity, and virulence- and survival-associated properties). In addition, a SASS 3100 high-volume air sampler and a matrix-assisted laser desorption ionization–time of flight mass spectrometry-based isolate screening procedure was used for these studies. The daytime level of airborne bacteria at the station was higher than the nighttime and outdoor levels, and the relative bacterial spore number was higher in outdoor air than at the station. The bacterial content, particle concentration, and size distribution were stable within each environment throughout the study (May to September 2010). The majority of the airborne bacteria belonged to the genera Bacillus, Micrococcus, and Staphylococcus, but a total of 37 different genera were identified in the air. These results suggest that anthropogenic sources are major contributors to airborne bacteria at subway stations and that such airborne communities could harbor virulence- and survival-associated properties of potential relevance for biological detection and surveillance, as well as for public health. Our findings also contribute to the development of realistic testing and evaluation schemes for biological detection/surveillance systems by providing information that can be used to mimic real-life operational airborne environments in controlled aerosol test chambers. PMID:22247150

  13. Raman lidar for remote control explosives in the subway

    Science.gov (United States)

    Grishkanich, Aleksandr; Redka, Dmitriy; Vasiliev, Sergey; Tishkov, Victor; Zhevlakov, Aleksandr

    2017-10-01

    Laser sensing can serve as a highly effective method of searching and monitoring of explosives in the subway. The first method is essence consists in definition the explosives concentration by excitation and registration ramans shifts at wavelength of λ = 0.261 - 0.532 μm at laser sounding. Preliminary results of investigation show the real possibility to register of 2,4,6-trinitrophenylmethylnitramine with concentration on surface at level of 108÷109 cm-3 on a safe distance 50 m from the object.

  14. Specialists' meeting on sodium fires

    Energy Technology Data Exchange (ETDEWEB)

    Kozlov, F A; Kuznetsova, R I [eds.

    1989-07-01

    The four sessions of the meeting covered the following topics: 1. general approach to fast reactor safety, standards of fire safety, maximum design basis accidents for sodium leaks and fires, status of sodium fires in different countries; 2. physical and chemical processes during combustion of sodium and its interaction with structural and technological materials and methods for structural protection; 3. methods of sodium fires extinguishing and measures for localizing aerosol combustion products, organization of fire fighting procedures, instruction and training of fire personnel; 4. elimination of the consequences of sodium fires.

  15. Specialists' meeting on sodium fires

    International Nuclear Information System (INIS)

    Kozlov, F.A.; Kuznetsova, R.I.

    1989-01-01

    The four sessions of the meeting covered the following topics: 1. general approach to fast reactor safety, standards of fire safety, maximum design basis accidents for sodium leaks and fires, status of sodium fires in different countries; 2. physical and chemical processes during combustion of sodium and its interaction with structural and technological materials and methods for structural protection; 3. methods of sodium fires extinguishing and measures for localizing aerosol combustion products, organization of fire fighting procedures, instruction and training of fire personnel; 4. elimination of the consequences of sodium fires

  16. Accidents - Chernobyl accident

    International Nuclear Information System (INIS)

    2004-01-01

    This file is devoted to the Chernobyl accident. It is divided in four parts. The first part concerns the accident itself and its technical management. The second part is relative to the radiation doses and the different contaminations. The third part reports the sanitary effects, the determinists ones and the stochastic ones. The fourth and last part relates the consequences for the other European countries with the case of France. Through the different parts a point is tackled with the measures taken after the accident by the other countries to manage an accident, the cooperation between the different countries and the groups of research and studies about the reactors safety, and also with the international medical cooperation, specially for the children, everything in relation with the Chernobyl accident. (N.C.)

  17. A consensus process on management of major burns accidents: lessons learned from the café fire in Volendam, The Netherlands

    NARCIS (Netherlands)

    Welling, L.; Boers, M.; Mackie, D. P.; Patka, P.; Bierens, J. J. L. M.; Luitse, J. S. K.; Kreis, R. W.

    2006-01-01

    PURPOSE: The optimum response to the different stages of a major burns incident is still not established. The fire in a café in Volendam on New Year's Eve 2000 was the worst incident in recent Dutch history and resulted in mass burn casualties. The fire has been the subject of several investigations

  18. Nuclear fuel cycle facility accident analysis handbook

    International Nuclear Information System (INIS)

    Ayer, J.E.; Clark, A.T.; Loysen, P.; Ballinger, M.Y.; Mishima, J.; Owczarski, P.C.; Gregory, W.S.; Nichols, B.D.

    1988-05-01

    The Accident Analysis Handbook (AAH) covers four generic facilities: fuel manufacturing, fuel reprocessing, waste storage/solidification, and spent fuel storage; and six accident types: fire, explosion, tornado, criticality, spill, and equipment failure. These are the accident types considered to make major contributions to the radiological risk from accidents in nuclear fuel cycle facility operations. The AAH will enable the user to calculate source term releases from accident scenarios manually or by computer. A major feature of the AAH is development of accident sample problems to provide input to source term analysis methods and transport computer codes. Sample problems and illustrative examples for different accident types are included in the AAH

  19. Examining the Interaction of Taxi and Subway Ridership for Sustainable Urbanization

    Directory of Open Access Journals (Sweden)

    Miaoyi Li

    2017-02-01

    Full Text Available A transit ridership study is an essential part of sustainability, and can provide a deep understanding of people’s travel patterns for efficient transportation development and urbanization. However, there is a lack of empirical studies comparing subway and taxi services, and their interactions within a city, that is to say, the interdependent transportation networks. Incorporating new data, this study aims to examine the spatial variation of urban taxi ridership due to the impacts of a new subway line operation opened in 2014 in Wuxi, China. We examine the spatial patterns and interactions of ridership in Wuxi by integrating taxi trajectory from GPS data and subway data from continuously collected fare transactions. The results indicated that the demand for taxi and subway usage is quite elastic with respect to both location and time, and the new subway’s opening had more influence on areas adjacent to subway stations and urban center-suburban travel. Furthermore, increases in travel time and distance would increase the demand for subway, while taxi trips largely represented movements for those locations that the subway could not reach. This paper betters the understanding of travel patterns through large volumes of transportation data for sustainable urbanization policy design.

  20. Epidemiology of subway-related fatalities in New York City, 1990-2003.

    Science.gov (United States)

    Gershon, Robyn R M; Pearson, Julie M; Nandi, Vijay; Vlahov, David; Bucciarelli-Prann, Angela; Tracy, Melissa; Tardiff, Kenneth; Galea, Sandro

    2008-01-01

    Subway transit is a relatively safe mode of transportation, yet compared to all other forms of mass transit in the United States (U.S.), subways have the highest fatality rate. The aim of this paper is to characterize subway-related fatalities in order to identify opportunities for risk reduction. Medical examiner records for all New York City (NYC) subway-related deaths (1990-2003) were reviewed. Data were abstracted on decedents' demographics and autopsy findings, including laboratory findings. There were 668 subway-related fatalities, of these, 10 (1.5%) were homicides, 343 (51.3%) were determined to be suicides, and 315 (47.2%) were accidental. Although decedent characteristics varied between fatality categories, they were not particularly informative with regard to prevention. Prevention strategies that focus on structural controls are likely to be most efficacious in improving the overall safety of the NYC subway systems. These findings suggest that structural rather than individual-level interventions would be most successful in preventing subway fatalities.

  1. Black carbon and particulate matter (PM2.5) concentrations in New York City's subway stations.

    Science.gov (United States)

    Vilcassim, M J Ruzmyn; Thurston, George D; Peltier, Richard E; Gordon, Terry

    2014-12-16

    The New York City (NYC) subway is the main mode of transport for over 5 million passengers on an average weekday. Therefore, airborne pollutants in the subway stations could have a significant impact on commuters and subway workers. This study looked at black carbon (BC) and particulate matter (PM2.5) concentrations in selected subway stations in Manhattan. BC and PM2.5 levels were measured in real time using a Micro-Aethalometer and a PDR-1500 DataRAM, respectively. Simultaneous samples were also collected on quartz filters for organic and elemental carbon (OC/EC) analysis and on Teflon filters for gravimetric and trace element analysis. In the underground subway stations, mean real time BC concentrations ranged from 5 to 23 μg/m(3), with 1 min average peaks >100 μg/m(3), while real time PM2.5 levels ranged from 35 to 200 μg/m(3). Mean EC levels ranged from 9 to 12.5 μg/m(3). At street level on the same days, the mean BC and PM2.5 concentrations were below 3 and 10 μg/m(3), respectively. This study shows that both BC soot and PM levels in NYC's subways are considerably higher than ambient urban street levels and that further monitoring and investigation of BC and PM subway exposures are warranted.

  2. Postulated accidents

    International Nuclear Information System (INIS)

    Ullrich, W.

    1980-01-01

    This lecture on 'Postulated Accidents' is the first of a series of lectures on the dynamic and transient behaviour of nuclear power plants, especially pressurized water reactors. The main points covered will be: Reactivity Accidents, Transients (Intact Loop) and Loss of Cooland Accidents (LOCA) including small leak. This lecture will discuss the accident analysis in general, the definition of the various operational phases, the accident classification, and, as an example, an accident sequence analysis on the basis of 'Postulated Accidents'. (orig./RW)

  3. Implications for visually stimulating advertisements on NYC subway platforms.

    Science.gov (United States)

    Fullwood, M Dottington; Basch, Corey H; LeBlanc, Michael

    2016-03-12

    Despite the fact that the New York City (NYC) Metropolitan Transportation Authority (MTA) no longer advertises tobacco products, there is no ban on ads for alcohol. The purpose of this pilot study was to evaluate the frequency of alcohol-related advertising content on the platforms of two populated subway lines in NYC. Advertisements were evaluated on one subway line (the green line) that runs through Bronx and Manhattan in NYC. In the stations included in the study, the total number of advertisements were tallied and classified according to the type of advertisement. When an advertisement for alcohol was identified, it was determined whether the ad was for an alcoholic beverage, or it if was for a different product but exhibited an alcoholic beverage in some way. A total of 26 advertisements were identified which marketed an alcohol product. An additional 24 ads were noted for marketing another product or service whereby, alcohol was depicted as being consumed. There was a statistically significant difference in ads between the different lines t (20.04)=7.62, padvertisements have, focus could shift to health promoting products, versus those that are deleterious.

  4. SART: an intelligent assistant system for subway control

    Directory of Open Access Journals (Sweden)

    P. Brézillon

    2000-12-01

    Full Text Available One of the main characteristics of a subway line is its large transport capacity (e.g., about 60000 travelers per hour in the Parisian subway combined with a regular transport supply. The regularity is particularly important at rush time - peak hours - when an incident can provoke important delays. Experience shows that the consequences of an incident are highly dependent on the context in which the incident occurs (e.g., peak hours or not. The decisions taken by the operators are heavily relied on the incident context, and operators often make different decisions for the same incident in different contexts. The project SART (French acronym for Support system for traffic control aims at developing an intelligent decision support system able of helping the operator in making decisions to solve an incident occurring on a line. This system relies on the notion of context. Context includes information and knowledge on the situation that do not intervene directly in the incident solving, but constrain the way in which the operator will choose a strategy at each step of the incident solving. The paper describes the SART project and highlights how Artificial Intelligence (AI techniques can contributeto knowledge acquisition and knowledge representation associated with its context of use. Particularly we discuss the notion of context and show how we use this notion to solve a real-world problem.

  5. Air quality inside subway metro indoor environment worldwide: A review.

    Science.gov (United States)

    Xu, Bin; Hao, Jinliang

    2017-10-01

    The air quality in the subway metro indoor microenvironment has been of particular public concern. With specific reference to the growing demand of green transportation and sustainable development, subway metro systems have been rapidly developed worldwide in last decades. The number of metro commuters has continuously increased over recent years in metropolitan cities. In some cities, metro system has become the primary public transportation mode. Although commuters typically spend only 30-40min in metros, the air pollutants emitted from various interior components of metro system as well as air pollutants carried by ventilation supply air are significant sources of harmful air pollutants that could lead to unhealthy human exposure. Commuters' exposure to various air pollutants in metro carriages may cause perceivable health risk as reported by many environmental health studies. This review summarizes significant findings in the literature on air quality inside metro indoor environment, including pollutant concentration levels, chemical species, related sources and health risk assessment. More than 160 relevant studies performed across over 20 countries were carefully reviewed. These comprised more than 2000 individual measurement trips. Particulate matters, aromatic hydrocarbons, carbonyls and airborne bacteria have been identified as the primary air pollutants inside metro system. On this basis, future work could focus on investigating the chronic health risks of exposure to various air pollutants other than PM, and/or further developing advanced air purification unit to improve metro in-station air quality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Patterns of suicidal behaviour in a metro subway system: a study of 306 cases injured by the Munich subway, 1980-1999.

    Science.gov (United States)

    Ladwig, Karl-Heinz; Baumert, Jens J

    2004-09-01

    As a basis for preventive strategies to reduce subway suicides, an investigation was undertaken to determine if there was a distinct pattern of subway suicidal behaviour. Data were taken from the Municipal Munich Subway System case registry (southern Germany) for all suicidal incidents on the track: purposely inflicted; date, time and location of incident, sex of victim, outcome. The analysis covered a 20 year observation period between 1980 and 1999, for which the Munich Municipal Office for Statistics also provided data of all deaths due to suicides within the city area of Munich. Suicide mortality was classified by the International Classification of Diseases, Ninth revision (codes E950-E959). A total of 306 incidents were documented with an annual mean of 16.5 cases. Case fatality was 66% (n=202). It was highest in winter and in higher aged groups. No significant time trend for incidences was observed. Median age of suicide attempters was 38 years. Most incidences (24.2%) were recorded for persons aged 20-29 years. The male: female ratio was 1.15 : 1. The peak time of day for incidences in women was during the late morning hours while significantly more men committed subway suicides during evening hours (p=0.001). No consistent seasonal variation was observed. In comparison to average suicide attempters, subjects committing subway suicides are markedly younger and they follow to a lesser extent established seasonal or circadian time patterns. More women are involved in subway suicides than would be expected. However, similarities to reports on behavioural patterns of subway suicides in other communities are striking.

  7. A study on the energy consumption unit of subway stations in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Wonhwa [Kyung-Pook National Univ., Daegu (Korea). Dept. of Architecture; Kim, Samuel [Dong-Eui Univ., Busan (Korea). Dept. of Building Systems Engineering

    2004-12-01

    As the Korean economy and society continues to develop, the number of subways are expected to increase. This increase will demand greater heating and cooling energy as well as convey a sharp rise in the overall energy consumption. This study aims to develop energy conservation and analysis for subways. This study shows the information, that is, tables, graphs, and charts concerning the trend in energy efficiency in subways between 1999 and 2001. We suggest a practical application for energy conservation methods and efficient energy use based on the investigations and analyses. (author)

  8. Electric shock and electrical fire specialty

    International Nuclear Information System (INIS)

    2011-02-01

    This book deals with electric shock and electrical fire, which is made up seven chapters. It describes of special measurement for electric shock and electrical fire. It mentions concretely about electrical fire analysis and precautionary measurement, electrical shock analysis cases, occurrence of static electricity and measurement, gas accident, analysis of equipment accident and precautionary measurement. The book is published to educate the measurement on electric shock and electrical fire by electrical safety technology education center in Korea Electrical Safety Corporation.

  9. Improvement of fire protection measures for nuclear power plants

    International Nuclear Information System (INIS)

    2012-01-01

    Improvements of fire protection measures for nuclear power plants were performed as following items: Development of fire hazard analysis method. Application of developed Fire Dynamic tool to actual plants, With regard to fire tests for the fire data acquisition, cable fire test and oil fire test were performed. Implementation of fire hazard analysis code and simulation were performed as following items: Fire analysis codes FDS, SYLVIA, CFAST were implemented in order to analyze the fire progression phenomena, Trial simulation of fire hazard as Metal-Clad Switch Gear Fire of ONAGAWA NPP in Tohoku earthquake (HEAF accident). (author)

  10. Fire safety engineering

    International Nuclear Information System (INIS)

    Smith, D.N.

    1989-01-01

    The periodic occurrence of large-scale, potentially disastrous industrial accidents involving fire in hazardous environments such as oilwell blowouts, petrochemical explosions and nuclear installations highlights the need for an integrated approach to fire safety engineering. Risk reduction 'by design' and rapid response are of equal importance in the saving of life and property in such situations. This volume of papers covers the subject thoroughly, touching on such topics as hazard analysis, safety design and testing, fire detection and control, and includes studies of fire hazard in the context of environment protection. (author)

  11. DHS Office of Health Affairs Chemical Defense Program Analyzes Subway Safety Against Chemical Terrorist Threats

    OpenAIRE

    Center for Homeland Defense and Security

    2012-01-01

    Center for Homeland Defense and Security, OUT OF THE CLASSROOM In an article for the journal Domestic Preparedness, Joselito Ignacio examines how to protect subway riders from chemical attacks. Ignacio graduated from the Center for Homeland Defense and Security in...

  12. Exposure level and distribution characteristics of airborne bacteria and fungi in Seoul metropolitan subway stations.

    Science.gov (United States)

    Kim, Ki Youn; Kim, Yoon Shin; Kim, Daekeun; Kim, Hyeon Tae

    2011-01-01

    The exposure level and distribution characteristics of airborne bacteria and fungi were assessed in the workers' activity areas (station office, bedroom, ticket office and driver's seat) and passengers' activity areas (station precinct, inside the passenger carriage, and platform) of the Seoul metropolitan subway. Among investigated areas, the levels of airborne bacteria and fungi in the workers' bedroom and station precincts were relatively high. No significant difference was found in the concentration of airborne bacteria and fungi between the underground and above ground activity areas of the subway. The genera identified in all subway activity areas with a 5% or greater detection rate were Staphylococcus, Micrococcus, Bacillus and Corynebacterium for airborne bacteria and Penicillium, Cladosporium, Chrysosporium, Aspergillus for airborne fungi. Staphylococcus and Micrococcus comprised over 50% of the total airborne bacteria and Penicillium and Cladosporium comprised over 60% of the total airborne fungi, thus these four genera are the predominant genera in the subway station.

  13. Continuously deformation monitoring of subway tunnel based on terrestrial point clouds

    NARCIS (Netherlands)

    Kang, Z.; Tuo, L.; Zlatanova, S.

    2012-01-01

    The deformation monitoring of subway tunnel is of extraordinary necessity. Therefore, a method for deformation monitoring based on terrestrial point clouds is proposed in this paper. First, the traditional adjacent stations registration is replaced by sectioncontrolled registration, so that the

  14. Study on energy saving of subway station based on orthogonal experimental method

    Science.gov (United States)

    Guo, Lei

    2017-05-01

    With the characteristics of quick, efficient and large amount transport, the subway has become an important way to solve urban traffic congestion. As the subway environment will follow the change of external environment factors such as temperature and load of personnel changes, three-dimensional numerical simulations study is conducted by using CFD software for air distribution of subway platform. The influence of different loads (the supply air temperature and velocity of air condition, personnel load, heat flux of the wall) on the subway platform flow field are also analysed. The orthogonal experiment method is applied to the numerical simulation analysis for human comfort under different parameters. Based on those results, the functional relationship between human comfort and the boundary conditions of the platform is produced by multiple linear regression fitting method, the order of major boundary conditions which affect human comfort is obtained. The above study provides a theoretical basis for the final energy-saving strategies.

  15. Gamma-ray dose rate in air on the subway lines in Tokyo metropolitan area

    International Nuclear Information System (INIS)

    Ogawa, Masayuki; Hosoda, Masahiro; Ogashiwa, Susumu; Fukushi, Masahiro

    2008-01-01

    Measurements of gamma-ray dose rates in air were performed on 12 subway lines in Tokyo from the perspective of health physics, because the subways are commonly used for commuting in the Tokyo metropolitan area. The results showed that the maximum dose rate (36.5 nGy/h) was 1.6 times higher than that of the minimum one (23.3 nGy/h), and that the dose rate in the subway car was 33% lower than the outside. Also the results strongly suggested that the dose rates depend on the concentration of natural radionuclide around the subway lines and the platform structures rather than the depth. (author)

  16. GPR applied to mapping utilities along the route of the Line 4 (yellow) subway tunnel construction in São Paulo City, Brazil

    Science.gov (United States)

    Porsani, Jorge Luís; Ruy, Yang Boo; Ramos, Fernanda Pereira; Yamanouth, Gisele R. B.

    2012-05-01

    The rapid industrial development and disorganized population growth in huge cities bring about various urban problems due to intense use of physical space on and below the surface. Subsurface problems in metropolitan areas are caused by subway line construction, which often follows the routes of utility networks, such as electric and telephone cables, water and gas pipes, storm sewers, etc. Usually, the main problems are related to damage or destruction of preexisting utilities, often putting human lives at risk. With the purpose of minimizing risks, GPR-profiling with 200 MHz antennae was done at two sites, both located in downtown São Paulo, Brazil. The objectives of this work were to map utilities or existing infrastructure in the subsurface in order to orient the construction of the Line 4 (yellow) subway tunnel in São Paulo. GPR profiles can detect water pipes, utility networks in the subsurface, and concrete foundation columns or pilings in subsoil up to 2 m depth. In addition, the GPR profiles also provided details of the target shapes in the subsurface. GPR interpretations combined with lithological information from boreholes and trenches opened in the study areas were extremely important in mapping of the correct spatial distribution of buried utilities at these two sites in São Paulo. This information improves and updates maps of utility placement, serves as a basis for planning of the geotechnical excavation of the Line 4 (yellow) subway tunnel in São Paulo, helps minimize problems related to destruction of preexisting utilities in the subsoil, and avoids risk of dangerous accidents.

  17. Managing Recurrent Congestion of Subway Network in Peak Hours with Station Inflow Control

    OpenAIRE

    Qingru Zou; Xiangming Yao; Peng Zhao; Fei Dou; Taoyuan Yang

    2018-01-01

    Station inflow control (SIC) is an important and effective method for reducing recurrent congestion during peak hours in the Beijing, Shanghai, and Guangzhou subway systems. This work proposes a practical and efficient method for establishing a static SIC scheme in normal weekdays for large-scale subway networks. First, a traffic assignment model without capacity constraint is utilized to determine passenger flow distributions on the network. An internal relationship between station inflows a...

  18. Effectiveness of Physical Barriers Installation for Prevention of Incidents in Mexico City’s Subway System

    OpenAIRE

    Portillo-Villasana, Gerardo de Jesús; Huerta-Barrientos, Aida; Dillarza Andrade, Yazmin

    2017-01-01

    Nowadays, suicides inside the installations of subway platforms are considered a public health problem in Mexico City. One solution to prevent them is the installation of physical barriers, but their high cost is unattractive for governmental authorities. Traditional approaches of research on the effectiveness of physical barriers for preventing suicides have been limited to analyzing statistically the effects of installing platform screen doors and blue lights on subway platforms. Although c...

  19. Podnikateľský zámer - Subway franchise

    OpenAIRE

    Leitner, Tomáš

    2013-01-01

    Subject of this thesis is to create a business plan for the branch of Subway franchise and acquaint with the concept of franchising. Theoretical part of the diploma thesis applies to definition of franchising, its characteristics, features, advantages and disadvantages for both parties and describes the elements necessary for setting up business. In application part of the thesis is introduced the business plan for opening of Subway branch.

  20. The effectiveness of platform screen doors for the prevention of subway suicides in South Korea.

    Science.gov (United States)

    Chung, Yong Woon; Kang, Sung Jin; Matsubayashi, Tetsuya; Sawada, Yasuyuki; Ueda, Michiko

    2016-04-01

    Subway suicide can significantly impact the general public. Platform Screen Doors (PSDs) are considered to be an effective strategy to prevent suicides at subway stations, but the evidence on their effectiveness is limited. We assessed the effectiveness of installing half- and full-height platform screen doors in reducing subway suicides using Poisson regression analysis. Ten-year monthly panel data for 121 subway stations between 2003 and 2012 in the Seoul metropolitan area were used for the analysis. We found that installing PSDs decreases fatal suicide cases by 89% (95% CI: 57-97%). We also found that the installation of full-height PSDs resulted in the elimination of subway suicides by completely blocking access to the track area; however, half-height PSDs, which do not extend to the ceiling of the platform, were not as effective as full-height ones. Our findings were based on the data from a single subway operator for a limited period of time. Accordingly, we did not consider the possibility that some passengers choose to die at a station run by other operators. Our study did not examine the potential substitution effects of other suicide methods. Installing physical barriers at subway stations can be an effective strategy to reduce the number of subway suicides; however, half-height PSDs are not as effective as full-height ones, even when they are as high as the height of an adult. Thus, these barriers should be made high enough so that nobody can climb over them. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Assessment of accident risks in the CRBRP. Volume 2. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-03-01

    Appendices to Volume I include core-related accident-sequence definition, CRBRP risk-assessment sequence-probability determinations, failure-probability data, accident scenario evaluation, radioactive material release analysis, ex-core accident analysis, safety philosophy and design features, calculation of reactor accident consequences, sensitivity study, and risk from fires.

  2. Predicting PM10 concentration in Seoul metropolitan subway stations using artificial neural network (ANN).

    Science.gov (United States)

    Park, Sechan; Kim, Minjeong; Kim, Minhae; Namgung, Hyeong-Gyu; Kim, Ki-Tae; Cho, Kyung Hwa; Kwon, Soon-Bark

    2018-01-05

    The indoor air quality of subway systems can significantly affect the health of passengers since these systems are widely used for short-distance transit in metropolitan urban areas in many countries. The particles generated by abrasion during subway operations and the vehicle-emitted pollutants flowing in from the street in particular affect the air quality in underground subway stations. Thus the continuous monitoring of particulate matter (PM) in underground station is important to evaluate the exposure level of PM to passengers. However, it is difficult to obtain indoor PM data because the measurement systems are expensive and difficult to install and operate for significant periods of time in spaces crowded with people. In this study, we predicted the indoor PM concentration using the information of outdoor PM, the number of subway trains running, and information on ventilation operation by the artificial neural network (ANN) model. As well, we investigated the relationship between ANN's performance and the depth of underground subway station. ANN model showed a high correlation between the predicted and actual measured values and it was able to predict 67∼80% of PM at 6 subway station. In addition, we found that platform shape and depth influenced the model performance. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Development of a subway operation incident delay model using accelerated failure time approaches.

    Science.gov (United States)

    Weng, Jinxian; Zheng, Yang; Yan, Xuedong; Meng, Qiang

    2014-12-01

    This study aims to develop a subway operational incident delay model using the parametric accelerated time failure (AFT) approach. Six parametric AFT models including the log-logistic, lognormal and Weibull models, with fixed and random parameters are built based on the Hong Kong subway operation incident data from 2005 to 2012, respectively. In addition, the Weibull model with gamma heterogeneity is also considered to compare the model performance. The goodness-of-fit test results show that the log-logistic AFT model with random parameters is most suitable for estimating the subway incident delay. First, the results show that a longer subway operation incident delay is highly correlated with the following factors: power cable failure, signal cable failure, turnout communication disruption and crashes involving a casualty. Vehicle failure makes the least impact on the increment of subway operation incident delay. According to these results, several possible measures, such as the use of short-distance and wireless communication technology (e.g., Wifi and Zigbee) are suggested to shorten the delay caused by subway operation incidents. Finally, the temporal transferability test results show that the developed log-logistic AFT model with random parameters is stable over time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Concentrations, properties, and health risk of PM2.5 in the Tianjin City subway system.

    Science.gov (United States)

    Wang, Bao-Qing; Liu, Jian-Feng; Ren, Zi-Hui; Chen, Rong-Hui

    2016-11-01

    A campaign was conducted to assess and compare the personal exposure in L3 of Tianjin subway, focusing on PM 2.5 levels, chemical compositions, morphology analysis, as well as the health risk of heavy metal in PM 2.5 . The results indicated that the average concentration of the PM 2.5 was 151.43 μg/m 3 inside the train of the subway during rush hours. PM 2.5 concentrations inside car under the ground are higher than those on the ground, and PM 2.5 concentrations on the platform are higher than those inside car. Regarding metal concentrations, the highest element in PM 2.5 samples was Fe; the level of which is 17.55 μg/m 3 . OC is a major component of PM 2.5 in Tianjin subway. Secondary organic carbon is the formation of gaseous organic pollutants in subway. SEM-EDX and TEM-EDX exhibit the presence of individual particle with a large metal content in the subway samples. For small Fe metal particles, iron oxide can be formed easily. With regard to their sources, Fe-containing particles are generated mainly from mechanical wear and friction processes at the rail-wheel-brake interfaces. The non-carcinogenic risk to metals Cr, Ni, Cu, Zn and Pb, and carcinogenic hazard of Cr and Ni were all below the acceptable level in L3 of Tianjin subway.

  5. Effect of Surface Blasting on Subway Tunnels- A Parametric Study

    Directory of Open Access Journals (Sweden)

    Hossein Entezari Zarch

    2017-01-01

    Full Text Available During wars and crises, the underground tunnels are used as a safe space. Therefore, the stability and safety of them under a blast is of particular importance. In this paper, the Finite Difference Method has been used to study the influence of the change in geotechnical parameters and depth on surface blasting on subway tunnels. Results showed that increasing the internal friction angle, modulus of elasticity and cohesion of the soil reduced the effects of blast loads on the vertical displacement and bending moment in the center of tunnel crown. Furthermore, the results showed that increasing the depth of the tunnel reduced the effects of blast loading. Comparing all parameters collectively showed that the increase in the modulus of elasticity of the soil and depth of the tunnel is the most effective in reducing the influence of the blast loads on the vertical displacement and bending moment of the tunnel crown, respectively.

  6. [WORKING CONDITIONS AND STATE OF HEALTH OF TBILISI SUBWAY EMPLOYEES].

    Science.gov (United States)

    Khunashvili, N; Tsimakuridze, Mar; Bakradze, L; Khachapuridze, N; Tsimakuridze, Maya

    2017-03-01

    For the purpose of preventive events complex hygienic, clinical-functional, laboratory and biostatic researches are implemented on the basis of Tbilisi Subway. Conditions of work are characterized by complex of unfavorable factors of the working environment and the labor process. Working environment is characterized by combination of unfavorable state of physical factors and air pollution with dust and toxic substances. The levels of noise and vibration refer to the 3.4 class of harmfulness. The content of dust and toxic substances corresponds to 3.1-3.2 classes of working conditions harmfulness. In the indexes of health status, the leading diseases are pathology of cardiovascular, nervous and digestive systems. Cause-effect relationships between working conditions and individual health indicators have been already established, which served as the basis for the development of comprehensive preventive health measures.

  7. Accidents with sulfuric acid

    Directory of Open Access Journals (Sweden)

    Rajković Miloš B.

    2006-01-01

    Full Text Available Sulfuric acid is an important industrial and strategic raw material, the production of which is developing on all continents, in many factories in the world and with an annual production of over 160 million tons. On the other hand, the production, transport and usage are very dangerous and demand measures of precaution because the consequences could be catastrophic, and not only at the local level where the accident would happen. Accidents that have been publicly recorded during the last eighteen years (from 1988 till the beginning of 2006 are analyzed in this paper. It is very alarming data that, according to all the recorded accidents, over 1.6 million tons of sulfuric acid were exuded. Although water transport is the safest (only 16.38% of the total amount of accidents in that way 98.88% of the total amount of sulfuric acid was exuded into the environment. Human factor was the common factor in all the accidents, whether there was enough control of the production process, of reservoirs or transportation tanks or the transport was done by inadequate (old tanks, or the accidents arose from human factor (inadequate speed, lock of caution etc. The fact is that huge energy, sacrifice and courage were involved in the recovery from accidents where rescue teams and fire brigades showed great courage to prevent real environmental catastrophes and very often they lost their lives during the events. So, the phrase that sulfuric acid is a real "environmental bomb" has become clearer.

  8. The influence of subway station design on noise levels.

    Science.gov (United States)

    Shah, Ravi R; Suen, Jonathan J; Cellum, Ilana P; Spitzer, Jaclyn B; Lalwani, Anil K

    2017-05-01

    To investigate the impact of subway station design on platform noise levels. Observational. Continuous A-weighted decibel (dBA) sound levels were recorded in 20 New York City subway stations, where trains entered on either a straight track or curved track in 10 stations each. Equivalent continuous noise levels (L eq ) at various locations on the boarding platform (inbound end, midplatform, and outbound end) during train entry and exit were compared between the straight and curved stations in broadband as well as narrow one-third octave bands. Overall, curved stations trended louder than straight stations, although the difference in broadband L eq did not reach statistical significance (curve, 83.4 dBA; straight, 82.6 dBA; P = .054). Noise levels were significantly louder at the inbound end of the platform during train entry (inbound, 89.7 dBA; mid, 85.5 dBA; outbound, 78.7 dBA; P < .001) and at the outbound end during train exit (inbound, 79.7 dBA; mid, 85.3 dBA; outbound, 89.1 dBA; P < .001). Narrow band analysis showed that curved stations were significantly louder than straight stations at 100 Hz and high frequencies from 8 to 20 kHz. Peak impact levels ranged from 104 to 121 dBA. Curved stations have a different noise profile compared to straight stations and are significantly louder than straight stations at high frequencies. Designing stations with straight tracks within the platform can help reduce commuter noise exposure. NA Laryngoscope, 127:1169-1174, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Study of the Accident Environment During Sea Transport of Nuclear Material: Analysis of an Engine-room Fire on a Purpose-built Ship (invited paper)

    International Nuclear Information System (INIS)

    Yamamoto, K.; Kitamura, T.; Shibata, K.; Ouchi, Y.; Ito, T.; Hohnstreiter, G.F.; Pierce, J.D.; Koski, J.A.; Dukart, R.K.

    2000-01-01

    The programme goal was to show that the IAEA safe transport regulations adequately cover the thermal effects of an engine-room fire on plutonium transport packages stowed aboard a purpose-built ship. The packages are stored in transport containers located in a cargo hold of the ship. For this study, it was assumed that the packages in No 5 hold, adjacent to an engine-room, could be subject to heating due to a fire in the engine-room. The No 5 hold and the engine-room are separated by a water-filled bulkhead. This study addressed the heat transfer from an engine-room fire that could heat and evaporate water out of the water-filled bulkhead and the resulting temperature conditions around the packages and inside the packages near their elastometric seals. (author)

  10. Study of accident environment during sea transport of nuclear material: Analysis of an engine room fire on a purpose built ship. Annex 5

    International Nuclear Information System (INIS)

    Yamamoto, K.; Shibata, H.; Ouchi, Y.; Kitamura, T.; Ito, T.; Hohnstreiter, G.F.; Pierce, J.D.; Koski, J.A.; Dukart, R.J.

    2001-01-01

    The program goal was to show that the IAEA safe transport regulations adequately cover the thermal effects of an engine-room fire on plutonium transportation packages stowed aboard a purpose built ship. The packages are stored in transportation containers located in a cargo hold of the ship. This study addressed the heat transfer from an engine-room fire that could heat and evaporate water out of the water-filled bulkhead and the resulting temperature conditions around the packages and inside the packages near their elastomeric seals. This study was designed to estimate the thermal response of a plutonium package in the hold of a purpose built ship during a shipboard fire, and furthermore, to confirm the sufficiency and adequacy of the current IAEA transport regulation

  11. Accident management

    International Nuclear Information System (INIS)

    Lutz, R.J.; Monty, B.S.; Liparulo, N.J.; Desaedeleer, G.

    1989-01-01

    The foundation of the framework for a Severe Accident Management Program is the contained in the Probabilistic Safety Study (PSS) or the Individual Plant Evaluations (IPE) for a specific plant. The development of a Severe Accident Management Program at a plant is based on the use of the information, in conjunction with other applicable information. A Severe Accident Management Program must address both accident prevention and accident mitigation. The overall Severe Accident Management framework must address these two facets, as a living program in terms of gathering the evaluating information, the readiness to respond to an event. Significant international experience in the development of severe accident management programs exist which should provide some direction for the development of Severe Accident Management in the U.S. This paper reports that the two most important elements of a Severe Accident Management Program are the Emergency Consultation process and the standards for measuring the effectiveness of individual Severe Accident Management Programs at utilities

  12. Unavoidable Accident

    OpenAIRE

    Grady, Mark F.

    2009-01-01

    In negligence law, "unavoidable accident" is the risk that remains when an actor has used due care. The counterpart of unavoidable accident is "negligent harm." Negligence law makes parties immune for unavoidable accident even when they have used less than due care. Courts have developed a number of methods by which they "sort" accidents to unavoidable accident or to negligent harm, holding parties liable only for the latter. These sorting techniques are interesting in their own right and als...

  13. Predictors of suicide and suicide attempt in subway stations: a population-based ecological study.

    Science.gov (United States)

    Niederkrotenthaler, Thomas; Sonneck, Gernot; Dervic, Kanita; Nader, Ingo W; Voracek, Martin; Kapusta, Nestor D; Etzersdorfer, Elmar; Mittendorfer-Rutz, Ellenor; Dorner, Thomas

    2012-04-01

    Suicidal behavior on the subway often involves young people and has a considerable impact on public life, but little is known about factors associated with suicides and suicide attempts in specific subway stations. Between 1979 and 2009, 185 suicides and 107 suicide attempts occurred on the subway in Vienna, Austria. Station-specific suicide and suicide attempt rates (defined as the frequency of suicidal incidents per time period) were modeled as the outcome variables in bivariate and multivariate Poisson regression models. Structural station characteristics (presence of a surveillance unit, train types used, and construction on street level versus other construction), contextual station characteristics (neighborhood to historical sites, size of the catchment area, and in operation during time period of extensive media reporting on subway suicides), and passenger-based characteristics (number of passengers getting on the trains per day, use as meeting point by drug users, and socioeconomic status of the population in the catchment area) were used as the explanatory variables. In the multivariate analyses, subway suicides increased when stations were served by the faster train type. Subway suicide attempts increased with the daily number of passengers getting on the trains and with the stations' use as meeting points by drug users. The findings indicate that there are some differences between subway suicides and suicide attempts. Completed suicides seem to vary most with train type used. Suicide attempts seem to depend mostly on passenger-based characteristics, specifically on the station's crowdedness and on its use as meeting point by drug users. Suicide-preventive interventions should concentrate on crowded stations and on stations frequented by risk groups.

  14. Concentration and characterization of airborne particles in Tehran's subway system.

    Science.gov (United States)

    Kamani, Hosein; Hoseini, Mohammad; Seyedsalehi, Mahdi; Mahdavi, Yousef; Jaafari, Jalil; Safari, Gholam Hosein

    2014-06-01

    Particulate matter is an important air pollutant, especially in closed environments like underground subway stations. In this study, a total of 13 elements were determined from PM10 and PM2.5 samples collected at two subway stations (Imam Khomeini and Sadeghiye) in Tehran's subway system. Sampling was conducted in April to August 2011 to measure PM concentrations in platform and adjacent outdoor air of the stations. In the Imam Khomeini station, the average concentrations of PM10 and PM2.5 were 94.4 ± 26.3 and 52.3 ± 16.5 μg m(-3) in the platform and 81.8 ± 22.2 and 35 ± 17.6 μg m(-3) in the outdoor air, respectively. In the Sadeghiye station, mean concentrations of PM10 and PM2.5 were 87.6 ± 23 and 41.3 ± 20.4 μg m(-3) in the platform and 73.9 ± 17.3 and 30 ± 15 μg m(-3), in the outdoor air, respectively. The relative contribution of elemental components in each particle fraction were accounted for 43% (PM10) and 47.7% (PM2.5) in platform of Imam Khomeini station and 15.9% (PM10) and 18.5% (PM2.5) in the outdoor air of this station. Also, at the Sadeghiye station, each fraction accounted for 31.6% (PM10) and 39.8% (PM2.5) in platform and was 11.7% (PM10) and 14.3% (PM2.5) in the outdoor. At the Imam Khomeini station, Fe was the predominant element to represent 32.4 and 36 % of the total mass of PM10 and PM2.5 in the platform and 11.5 and 13.3% in the outdoor, respectively. At the Sadeghiye station, this element represented 22.7 and 29.8% of total mass of PM10 and PM2.5 in the platform and 8.7 and 10.5% in the outdoor air, respectively. Other major crustal elements were 5.8% (PM10) and 5.3% (PM2.5) in the Imam Khomeini station platform and 2.3 and 2.4% in the outdoor air, respectively. The proportion of other minor elements was significantly lower, actually less than 7% in total samples, and V was the minor concentration in total mass of PM10 and PM2.5 in both platform stations.

  15. Fighting forest fires in Brazil

    Science.gov (United States)

    José Carlos Mendes de Morais

    2013-01-01

    Fire has been used in Brazil for many years, but the increased use of this tool, combined with natural events and the presence of large forest and agricultural areas, has led to a significant jump in the number of forest fires, most of them caused by accident. To optimize existing resources and to cope with growing demand, action levels were adopted according to the...

  16. Fire testing for package approval

    International Nuclear Information System (INIS)

    Burgess, M.H.; Fry, C.J.

    1990-01-01

    The IAEA Transport Regulations require packaging systems for radioactive material to survive transport accidents without a significant increase in hazard to members of the public. Tests used to demonstrate this include a fire or 'thermal' test which may be a practical demonstration or based on calculations. Work at Winfrith, involving the development of computer models and pool fire techniques, has given an improved understanding of physical processes. This has been used to improve computer models and pool fire techniques. The paper covers the regulatory requirements for fire testing, the basic physics of fires, practical tests, computer modelling and their applications to package design. We have confidence in our ability to predict temperatures and other conditions in accident situations and can illustrate the important features of fires with experimental evidence. (author)

  17. The role of subway travel in an influenza epidemic: a New York City simulation.

    Science.gov (United States)

    Cooley, Philip; Brown, Shawn; Cajka, James; Chasteen, Bernadette; Ganapathi, Laxminarayana; Grefenstette, John; Hollingsworth, Craig R; Lee, Bruce Y; Levine, Burton; Wheaton, William D; Wagener, Diane K

    2011-10-01

    The interactions of people using public transportation in large metropolitan areas may help spread an influenza epidemic. An agent-based model computer simulation of New York City's (NYC's) five boroughs was developed that incorporated subway ridership into a Susceptible-Exposed-Infected-Recovered disease model framework. The model contains a total of 7,847,465 virtual people. Each person resides in one of the five boroughs of NYC and has a set of socio-demographic characteristics and daily behaviors that include age, sex, employment status, income, occupation, and household location and membership. The model simulates the interactions of subway riders with their workplaces, schools, households, and community activities. It was calibrated using historical data from the 1957-1958 influenza pandemics and from NYC travel surveys. The surveys were necessary to enable inclusion of subway riders into the model. The model results estimate that if influenza did occur in NYC with the characteristics of the 1957-1958 pandemic, 4% of transmissions would occur on the subway. This suggests that interventions targeted at subway riders would be relatively ineffective in containing the epidemic. A number of hypothetical examples demonstrate this feature. This information could prove useful to public health officials planning responses to epidemics.

  18. Numerical Simulations for a Typical Train Fire in China

    Directory of Open Access Journals (Sweden)

    W. K. Chow

    2011-01-01

    Full Text Available Railway is the key transport means in China including the Mainland, Taiwan, and Hong Kong. Consequent to so many big arson and accidental fires in the public transport systems including trains and buses, fire safety in passenger trains is a concern. Numerical simulations with Computational Fluid Dynamics on identified fire scenarios with typical train compartments in China will be reported in this paper. The heat release rate of the first ignited item was taken as the input parameter. The mass lost rate of fuel vapor of other combustibles was estimated to predict the resultant heat release rates by the combustion models in the software. Results on air flow, velocity vectors, temperature distribution, smoke layer height, and smoke spread patterns inside the train compartment were analyzed. The results are useful for working out appropriate fire safety measures for train vehicles and determining the design fire for subway stations and railway tunnels.

  19. 49 CFR 1242.15 - Roadway, tunnels and subways, bridges and culverts, ties, rails, other track material, ballast...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Roadway, tunnels and subways, bridges and culverts, ties, rails, other track material, ballast, track laying and surfacing, and road property damaged... RAILROADS 1 Operating Expenses-Way and Structures § 1242.15 Roadway, tunnels and subways, bridges and...

  20. Stationary centrifugal mass energy storage at the Hamburg subway; Stationaerer Schwungmassen-Energiespeicher bei der Hamburger U-Bahn

    Energy Technology Data Exchange (ETDEWEB)

    Steinhorst, F. [Hamburger Hochbahn AG, Hamburg (Germany). Abt. Energieanlagen; Jonassen, I.; Peters, A. [Hamburger Hochbahn AG, Hamburg (Germany). Fachbereich Energieversorgung

    2008-07-01

    A stationary energy storage is to be used as a model in a substation of the Hamburg subway network with a view to the environmentally compatible and technically proper use of the brake energy available in electrified local public transport systems. A further question to be reviewed is whether the use of other energy storages in the subway network is a reasonable solution. (orig.)

  1. Improvement of fire protection measures for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    Improvements of fire protection measures for nuclear power plants were performed as following items: Development of fire hazard analysis method. Application of developed Fire Dynamic Tool to actual plants (FDT{sup S}), With regard to fire tests for the fire data acquisition, cable fire test and High Energy Arcing Faults (HEAF) fire test were performed. Implementation of fire hazard analysis code and simulation were performed as following items: Fire analysis codes FDS, SYLVIA, and CFAST were implemented in order to analyze the fire progression phenomena. Trial simulation of HEAF accident of Onagawa NPP in Tohoku earthquake. (author)

  2. Predicted occurrence rate of severe transportation accidents involving large casks

    International Nuclear Information System (INIS)

    Dennis, A.W.

    1978-01-01

    A summary of the results of an investigation of the severities of highway and railroad accidents as they relate to the shipment of large radioactive materials casks is discussed. The accident environments considered are fire, impact, crash, immersion, and puncture. For each of these environments, the accident severities and their predicted frequencies of occurrence are presented. These accident environments are presented in tabular and graphic form to allow the reader to evaluate the probabilities of occurrence of the accident parameter severities he selects

  3. Preventing accidents

    Science.gov (United States)

    2005-08-01

    As the most effective strategy for improving safety is to prevent accidents from occurring at all, the Volpe Center applies a broad range of research techniques and capabilities to determine causes and consequences of accidents and to identify, asses...

  4. A long-time limit for world subway networks.

    Science.gov (United States)

    Roth, Camille; Kang, Soong Moon; Batty, Michael; Barthelemy, Marc

    2012-10-07

    We study the temporal evolution of the structure of the world's largest subway networks in an exploratory manner. We show that, remarkably, all these networks converge to a shape that shares similar generic features despite their geographical and economic differences. This limiting shape is made of a core with branches radiating from it. For most of these networks, the average degree of a node (station) within the core has a value of order 2.5 and the proportion of k = 2 nodes in the core is larger than 60 per cent. The number of branches scales roughly as the square root of the number of stations, the current proportion of branches represents about half of the total number of stations, and the average diameter of branches is about twice the average radial extension of the core. Spatial measures such as the number of stations at a given distance to the barycentre display a first regime which grows as r(2) followed by another regime with different exponents, and eventually saturates. These results--difficult to interpret in the framework of fractal geometry--confirm and yield a natural explanation in the geometric picture of this core and their branches: the first regime corresponds to a uniform core, while the second regime is controlled by the interstation spacing on branches. The apparent convergence towards a unique network shape in the temporal limit suggests the existence of dominant, universal mechanisms governing the evolution of these structures.

  5. Hyperloops, Nuclear Spacecraft, and the New York City Subway

    Science.gov (United States)

    Granade, Stephen

    2014-03-01

    Frustrated by the speed and high cost-per-mile of the California High-Speed Rail project linking Los Angeles with San Francisco, Elon Musk proposed the Hyperloop: a high-speed train running in a sealed, partially-evacuated tube. Musk released a white paper that described the technology and concluded that the Hyperloop could be built for less than a tenth of a cost of the California High-Speed Rail. Musk's white paper focused heavily on the scientific and technical questions that must be answered, but public transportation is a domain at the intersection of science and society. Public transportation infrastructure is shaped as much by the pressures of government and citizens as by the technology behind the transportation. Tube-based transport like the Hyperloop has been proposed before, but has never gone further than words on a page. Why? Historical examples like the development of the New York City subway and the proposed nuclear-powered Orion spacecraft shed light on the societal barriers that new transportation must overcome, and help illuminate why technology-based answers are not a full response to transportation questions.

  6. The Tokyo subway sarin attack-lessons learned

    International Nuclear Information System (INIS)

    Okumura, T.; Hisaoka, T.; Yamada, A.; Naito, T.; Isonuma, H.; Okumura, S.; Miura, K.; Sakurada, M.; Maekawa, H.; Ishimatsu, S.; Takasu, N.; Suzuki, K.

    2005-01-01

    The sarin gas attack in the Tokyo subway system is reviewed from a clinical toxicology perspective. Based on the lessons learned from this attack, the following areas should be addressed on a global scale. First, an adequate supply of protective equipment is required, including level B protective equipment with a pressure demand breathing apparatus. In addition, a system should be established that enables a possible cause to be determined based on symptoms, physical findings, general laboratory tests, and a simple qualitative analysis for poisonous substances. If an antidote is needed, the system should enable it to be administered to the victims as quickly as possible. Preparation for a large-scale chemical attack by terrorists requires the prior establishment of a detailed decontamination plan that utilizes not only mass decontamination facilities but also public facilities in the area. A system should be established for summarizing, evaluating, and disseminating information on poisonous substances. Finally, a large-scale scientific investigation of the Tokyo sarin attack should be conducted to examine its long-term and subclinical effects and the effects of exposure to asymptomatic low levels of sarin

  7. Airborne particulate metals in the New York City subway: a pilot study to assess the potential for health impacts.

    Science.gov (United States)

    Grass, David S; Ross, James M; Family, Farnosh; Barbour, Jonathan; James Simpson, H; Coulibaly, Drissa; Hernandez, Jennifer; Chen, Yingdi; Slavkovich, Vesna; Li, Yongliang; Graziano, Joseph; Santella, Regina M; Brandt-Rauf, Paul; Chillrud, Steven N

    2010-01-01

    A prior study in New York City observed that airborne concentrations of three metals found in steel - iron, manganese, and chromium - are more than 100 times higher in the subway system than in aboveground air. To investigate the potential for health effects of exposure at these levels, we conducted a pilot study of subway workers comparing personal exposures to steel dust with biomarkers of metal exposure, oxidative stress, and DNA damage in blood and urine samples. Workers wore a personal air sampler operating at 4L/m for one to three work shifts with blood and urine samples collected at the end of the final shift. We found that PM(2.5) exposures varied among subway workers on the basis of job title and job activity. The subway workers' mean time-weighted PM(2.5) exposure was 52 microg/m3, with a median of 27 microg/m3, and a range of 6-469 microg/m3. The observed concentrations of PM(2.5), iron, manganese, and chromium fell well below occupational standards. Biomarker concentrations among the 39 subway workers were compared with a group of 11 bus drivers, and a group of 25 suburban office workers. Concentrations of DNA-protein crosslinks and chromium in plasma were significantly higher in subway workers than in bus drivers, but no significant difference was observed for these biomarkers between subway workers and office workers. Urinary isoprostane concentrations were significantly correlated with the number of years working in the subway system, and were detected at higher, though not significantly higher, concentrations in subway workers than in bus drivers or office workers. At the group level, there was no consistent pattern of biomarker concentrations among subway workers significantly exceeding those of the bus drivers and office workers. At the individual level, steel dust exposure was not correlated with any of the biomarkers measured.

  8. Internal Exposure of a Seoul Subway Passenger due to Radon Inhalation: Before and After PSD Installation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji-Yong; Kim, Eun-Hee [Seoul National University, Seoul (Korea, Republic of)

    2015-05-15

    Radon is the major source of public exposure to natural radiation and is also known to cause lung cancer. Platform screen doors (PSD) were installed primarily for passenger's safety purposes. Radon concentration and aerosol distribution have been changed since PSD installation. In this study, we have assessed the annual effective dose of regular subway passengers, before and after PSD installation, by employing current available data on air concentration of radon in Seoul subways with aerosol size distributions taken into account. ICRP recommends that the reference value for internal dose from radon be between 1.0 and 20.0 mSv. Korean Ministry of Environment enacted the indoor radon regulation, which requires the indoor radon level should not exceed 148 Bq/m{sup 3}. Radon concentrations in Seoul subways and annual dose estimates meet the requirements.

  9. Internal Exposure of a Seoul Subway Passenger due to Radon Inhalation: Before and After PSD Installation

    International Nuclear Information System (INIS)

    Shin, Ji-Yong; Kim, Eun-Hee

    2015-01-01

    Radon is the major source of public exposure to natural radiation and is also known to cause lung cancer. Platform screen doors (PSD) were installed primarily for passenger's safety purposes. Radon concentration and aerosol distribution have been changed since PSD installation. In this study, we have assessed the annual effective dose of regular subway passengers, before and after PSD installation, by employing current available data on air concentration of radon in Seoul subways with aerosol size distributions taken into account. ICRP recommends that the reference value for internal dose from radon be between 1.0 and 20.0 mSv. Korean Ministry of Environment enacted the indoor radon regulation, which requires the indoor radon level should not exceed 148 Bq/m 3 . Radon concentrations in Seoul subways and annual dose estimates meet the requirements

  10. Weighted complex network analysis of the Beijing subway system: Train and passenger flows

    Science.gov (United States)

    Feng, Jia; Li, Xiamiao; Mao, Baohua; Xu, Qi; Bai, Yun

    2017-05-01

    In recent years, complex network theory has become an important approach to the study of the structure and dynamics of traffic networks. However, because traffic data is difficult to collect, previous studies have usually focused on the physical topology of subway systems, whereas few studies have considered the characteristics of traffic flows through the network. Therefore, in this paper, we present a multi-layer model to analyze traffic flow patterns in subway networks, based on trip data and an operation timetable obtained from the Beijing Subway System. We characterize the patterns in terms of the spatiotemporal flow size distributions of both the train flow network and the passenger flow network. In addition, we describe the essential interactions between these two networks based on statistical analyses. The results of this study suggest that layered models of transportation systems can elucidate fundamental differences between the coexisting traffic flows and can also clarify the mechanism that causes these differences.

  11. How to reduce the number of accidents

    CERN Multimedia

    2012-01-01

    Among the safety objectives that the Director-General has established for CERN in 2012 is a reduction in the number of workplace accidents.   The best way to prevent workplace accidents is to learn from experience. This is why any accident, fire, instance of pollution, or even a near-miss, should be reported using the EDH form that can be found here. All accident reports are followed up. The departments investigate all accidents that result in sick leave, as well as all the more common categories of accidents at CERN, essentially falls (slipping, falling on stairs, etc.), regardless of whether or not they lead to sick leave. By studying the accident causes that come to light in this way, it is possible to take preventive action to avoid such accidents in the future. If you have any questions, the HSE Unit will be happy to answer them. Contact us at safety-general@cern.ch. HSE Unit

  12. Accident management for severe accidents

    International Nuclear Information System (INIS)

    Bari, R.A.; Pratt, W.T.; Lehner, J.; Leonard, M.; Disalvo, R.; Sheron, B.

    1988-01-01

    The management of severe accidents in light water reactors is receiving much attention in several countries. The reduction of risk by measures and/or actions that would affect the behavior of a severe accident is discussed. The research program that is being conducted by the US Nuclear Regulatory Commission focuses on both in-vessel accident management and containment and release accident management. The key issues and approaches taken in this program are summarized. 6 refs

  13. Culture-independent analysis of aerosol microbiology in a metropolitan subway system.

    Science.gov (United States)

    Robertson, Charles E; Baumgartner, Laura K; Harris, J Kirk; Peterson, Kristen L; Stevens, Mark J; Frank, Daniel N; Pace, Norman R

    2013-06-01

    The goal of this study was to determine the composition and diversity of microorganisms associated with bioaerosols in a heavily trafficked metropolitan subway environment. We collected bioaerosols by fluid impingement on several New York City subway platforms and associated sites in three sampling sessions over a 1.5-year period. The types and quantities of aerosolized microorganisms were determined by culture-independent phylogenetic analysis of small-subunit rRNA gene sequences by using both Sanger (universal) and pyrosequencing (bacterial) technologies. Overall, the subway bacterial composition was relatively simple; only 26 taxonomic families made up ~75% of the sequences determined. The microbiology was more or less similar throughout the system and with time and was most similar to outdoor air, consistent with highly efficient air mixing in the system. Identifiable bacterial sequences indicated that the subway aerosol assemblage was composed of a mixture of genera and species characteristic of soil, environmental water, and human skin commensal bacteria. Eukaryotic diversity was mainly fungal, dominated by organisms of types associated with wood rot. Human skin bacterial species (at 99% rRNA sequence identity) included the Staphylococcus spp. Staphylococcus epidermidis (the most abundant and prevalent commensal of the human integument), S. hominis, S. cohnii, S. caprae, and S. haemolyticus, all well-documented human commensal bacteria. We encountered no organisms of public health concern. This study is the most extensive culture-independent survey of subway microbiota so far and puts in place pre-event information required for any bioterrorism surveillance activities or monitoring of the microbiological impact of recent subway flooding events.

  14. Subway-Related Trauma: An Urban Public Health Issue with a High Case-Fatality Rate.

    Science.gov (United States)

    Rodier, Simon G; DiMaggio, Charles J; Wall, Stephen; Sim, Vasiliy; Frangos, Spiros G; Ayoung-Chee, Patricia; Bukur, Marko; Tandon, Manish; Todd, S Rob; Marshall, Gary T

    2018-05-09

    Between 1990 and 2003, there were 668 subway-related fatalities in New York City. However, subway-related trauma remains an understudied area of injury-related morbidity and mortality. The objective of this study was to characterize the injuries and events leading up to the injuries of all patients admitted after subway-related trauma. We conducted a retrospective case series of subway-related trauma at a Level I trauma center from 2001 to 2016. Descriptive epidemiology of patient demographics, incident details, injuries, and outcomes were analyzed. Over 15 years, 254 patients were admitted for subway-related trauma. The mean (standard error of the mean) age was 41 (1.0) years, 80% were male (95% confidence interval [CI] 74-84%) and median Injury Severity Score was 14 (interquartile range [IQR] 5-24). The overall case-fatality rate was 10% (95% CI 7-15%). The most common injuries were long-bone fractures, intracranial hemorrhage, and traumatic amputations. Median length of stay was 6 days (IQR 1-18 days). Thirty-seven percent of patients required surgical intervention. At the time of injury, 55% of patients (95% CI 49-61%) had a positive urine drug or alcohol screen, 16% (95% CI 12-21%) were attempting suicide, and 39% (95% CI 33-45%) had a history of psychiatric illness. Subway-related trauma is associated with a high case-fatality rate. Alcohol or drug intoxication and psychiatric illness can increase the risk of this type of injury. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Chemical compositions of subway particles in Seoul, Korea determined by a quantitative single particle analysis.

    Science.gov (United States)

    Kang, Sunni; Hwang, HeeJin; Park, YooMyung; Kim, HyeKyoung; Ro, Chul-Un

    2008-12-15

    A novel single particle analytical technique, low-Z particle electron probe X-ray microanalysis, was applied to characterize seasonal subway samples collected at a subway station in Seoul, Korea. For all 8 samples collected twice in each season, 4 major types of subway particles, based on their chemical compositions, are significantly encountered: Fe-containing; soil-derived; carbonaceous; and secondary nitrate and/or sulfate particles. Fe-containing particles are generated indoors from wear processes at rail-wheel-brake interfaces while the others may be introduced mostly from the outdoor urban atmosphere. Fe-containing particles are the most frequently encountered with relative abundances in the range of 61-79%. In this study, it is shown that Fe-containing subway particles almost always exist either as partially or fully oxidized forms in underground subway microenvironments. Their relative abundances of Fe-containing particles increase as particle sizes decrease. Relative abundances of Fe-containing particles are higher in morning samples than in afternoon samples because of heavier train traffic in the morning. In the summertime samples, Fe-containing particles are the most abundantly encountered, whereas soil-derived and nitrate/sulfate particles are the least encountered, indicating the air-exchange between indoor and outdoor environments is limited in the summer, owing to the air-conditioning in the subway system. In our work, it was observed that the relative abundances of the particles of outdoor origin vary somewhat among seasonal samples to a lesser degree, reflecting that indoor emission sources predominate.

  16. Modeling of compartment fire

    International Nuclear Information System (INIS)

    Sathiah, P.; Siccama, A.; Visser, D.; Komen, E.

    2011-01-01

    Fire accident in a containment is a serious threat to nuclear reactors. Fire can cause substantial loss to life and property. The risk posed by fire can also exceed the risk from internal events within a nuclear reactor. Numerous research efforts have been performed to understand and analyze the phenomenon of fire in nuclear reactor and its consequences. Modeling of fire is an important subject in the field of fire safety engineering. Two approaches which are commonly used in fire modeling are zonal modeling and field modeling. The objective of this work is to compare zonal and field modeling approach against a pool fired experiment performed in a well-confined compartment. Numerical simulations were performed against experiments, which were conducted within PRISME program under the framework of OECD. In these experiments, effects of ventilation flow rate on heat release rate in a confined and mechanically ventilated compartment is investigated. Time dependent changes in gas temperature and oxygen mass fraction were measured. The trends obtained by numerical simulation performed using zonal model and field model compares well with experiments. Further validation is needed before this code can be used for fire safety analyses. (author)

  17. Radon exposure assessment for underground workers: A case of Seoul Subway Police officers in Korea

    International Nuclear Information System (INIS)

    Song, M. H.; Chang, B. U.; Kim, Y.; Cho, K. W.

    2011-01-01

    The objective of this study is the systematic and individual assessment of the annual effective dose due to inhaled radon for the Seoul Subway Police officers, Korea. The annual average radon concentrations were found to be in the range of 18.9-114 Bq -3 in their workplaces. The total annual effective doses which may likely to be received on duty were assessed to be in the range of 0.41-1.64 mSv.y -1 . These were well below the recommended action level 10 mSv.y -1 by ICRP. However, the effective doses were higher than subway station staff in Seoul, Korea. (authors)

  18. Accidents in nuclear ships

    Energy Technology Data Exchange (ETDEWEB)

    Oelgaard, P L [Risoe National Lab., Roskilde (Denmark); [Technical Univ. of Denmark, Lyngby (Denmark)

    1996-12-01

    This report starts with a discussion of the types of nuclear vessels accidents, in particular accidents which involve the nuclear propulsion systems. Next available information on 61 reported nuclear ship events in considered. Of these 6 deals with U.S. ships, 54 with USSR ships and 1 with a French ship. The ships are in almost all cases nuclear submarines. Only events that involve the sinking of vessels, the nuclear propulsion plants, radiation exposures, fires/explosions, sea-water leaks into the submarines and sinking of vessels are considered. For each event a summary of available information is presented, and comments are added. In some cases the available information is not credible, and these events are neglected. This reduces the number of events to 5 U.S. events, 35 USSR/Russian events and 1 French event. A comparison is made between the reported Soviet accidents and information available on dumped and damaged Soviet naval reactors. It seems possible to obtain good correlation between the two types of events. An analysis is made of the accident and estimates are made of the accident probabilities which are found to be of the order of 10{sup -3} per ship reactor years. It if finally pointed out that the consequences of nuclear ship accidents are fairly local and does in no way not approach the magnitude of the Chernobyl accident. It is emphasized that some of the information on which this report is based, may not be correct. Consequently some of the results of the assessments made may not be correct. (au).

  19. Accidents in nuclear ships

    International Nuclear Information System (INIS)

    Oelgaard, P.L.

    1996-12-01

    This report starts with a discussion of the types of nuclear vessels accidents, in particular accidents which involve the nuclear propulsion systems. Next available information on 61 reported nuclear ship events in considered. Of these 6 deals with U.S. ships, 54 with USSR ships and 1 with a French ship. The ships are in almost all cases nuclear submarines. Only events that involve the sinking of vessels, the nuclear propulsion plants, radiation exposures, fires/explosions, sea-water leaks into the submarines and sinking of vessels are considered. For each event a summary of available information is presented, and comments are added. In some cases the available information is not credible, and these events are neglected. This reduces the number of events to 5 U.S. events, 35 USSR/Russian events and 1 French event. A comparison is made between the reported Soviet accidents and information available on dumped and damaged Soviet naval reactors. It seems possible to obtain good correlation between the two types of events. An analysis is made of the accident and estimates are made of the accident probabilities which are found to be of the order of 10 -3 per ship reactor years. It if finally pointed out that the consequences of nuclear ship accidents are fairly local and does in no way not approach the magnitude of the Chernobyl accident. It is emphasized that some of the information on which this report is based, may not be correct. Consequently some of the results of the assessments made may not be correct. (au)

  20. Accident prevention in power plants

    International Nuclear Information System (INIS)

    Steyrer, H.

    Large thermal power plants are insured to a great extent at the Industrial Injuries Insurance Institute of Instrument and Electric Engineering. Approximately 4800 employees are registered. The accident frequency according to an evaluation over 12 months lies around 79.8 per year and 1000 employees in fossil-fired power plants, around 34.1 per year and 1000 employees in nuclear power plants, as in nuclear power plants coal handling and ash removal are excluded. Injuries due to radiation were not registered. The crucial points of accidents are mechanical injuries received on solid, sharp-edged and pointed objects (fossil-fired power plants 28.6%, nuclear power plants 41.5%), stumbling, twisting or slipping (fossil-fired power plants 21.8%, nuclear power plants 19.5%) and injuries due to moving machine parts (only nuclear power plants 12.2%). However, accidents due to burns or scalds obtain with 4.2% and less a lower portion than expected. The accident statistics can explain this fact in a way that the typical power plant accident does not exist. (orig./GL) [de

  1. Fire protection and fire fighting in nuclear installations

    International Nuclear Information System (INIS)

    1989-01-01

    Fires are a threat to all technical installations. While fire protection has long been a well established conventional discipline, its application to nuclear facilities requires special considerations. Nevertheless, for a long time fire engineering has been somewhat neglected in the design and operation of nuclear installations. In the nuclear industry, the Browns Ferry fire in 1975 brought about an essential change in the attention paid to fire problems. Designers and plant operators, as well as insurance companies and regulators, increased their efforts to develop concepts and methods for reducing fire risks, not only to protect the capital investment in nuclear plants but also to consider the potential secondary effects which could lead to nuclear accidents. Although the number of fires in nuclear installations is still relatively large, their overall importance to the safety of nuclear power plants was not considered to be very high. Only more recently have probabilistic analyses changed this picture. The results may well have to be taken into account more carefully. Various aspects of fire fighting and fire protection were discussed during the Symposium, the first of its kind to be organized by the IAEA. It was convened in co-operation with several organizations working in the nuclear or fire protection fields. The intention was to gather experts from nuclear engineering areas and the conventional fire protection field at one meeting with a view to enhancing the exchange of information and experience and to presenting current knowledge on the various disciplines involved. The presentations at the meeting were subdivided into eight sessions: standards and licensing (6 papers); national fire safety practices (7 papers); fire safety by design (11 papers); fire fighting (2 papers); computer fire modeling (7 papers); fire safety in fuel center facilities (7 papers); fire testing of materials (3 papers); fire risk assessment (5 papers). A separate abstract was

  2. 25 CFR 226.41 - Accidents to be reported.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Accidents to be reported. 226.41 Section 226.41 Indians... LANDS FOR OIL AND GAS MINING Requirements of Lessees § 226.41 Accidents to be reported. Lessee shall make a complete report to the Superintendent of all accidents, fires, or acts of theft and vandalism...

  3. Black Carbon and Particulate Matter (PM2.5) Concentrations in New York City’s Subway Stations

    Science.gov (United States)

    2015-01-01

    The New York City (NYC) subway is the main mode of transport for over 5 million passengers on an average weekday. Therefore, airborne pollutants in the subway stations could have a significant impact on commuters and subway workers. This study looked at black carbon (BC) and particulate matter (PM2.5) concentrations in selected subway stations in Manhattan. BC and PM2.5 levels were measured in real time using a Micro-Aethalometer and a PDR-1500 DataRAM, respectively. Simultaneous samples were also collected on quartz filters for organic and elemental carbon (OC/EC) analysis and on Teflon filters for gravimetric and trace element analysis. In the underground subway stations, mean real time BC concentrations ranged from 5 to 23 μg/m3, with 1 min average peaks >100 μg/m3, while real time PM2.5 levels ranged from 35 to 200 μg/m3. Mean EC levels ranged from 9 to 12.5 μg/m3. At street level on the same days, the mean BC and PM2.5 concentrations were below 3 and 10 μg/m3, respectively. This study shows that both BC soot and PM levels in NYC’s subways are considerably higher than ambient urban street levels and that further monitoring and investigation of BC and PM subway exposures are warranted. PMID:25409007

  4. Spatial distribution of particulate matter (PM10 and PM2.5) in Seoul Metropolitan Subway stations.

    Science.gov (United States)

    Kim, Ki Youn; Kim, Yoon Shin; Roh, Young Man; Lee, Cheol Min; Kim, Chi Nyon

    2008-06-15

    The aims of this study are to examine the concentrations of PM10 and PM2.5 in areas within the Seoul Metropolitan Subway network and to provide fundamental data in order to protect respiratory health of subway workers and passengers from air pollutants. A total of 22 subway stations located on lines 1-4 were selected based on subway official's guidance. At these stations both subway worker areas (station offices, rest areas, ticket offices and driver compartments) and passengers areas (station precincts, subway carriages and platforms) were the sites used for measuring the levels of PM. The mean concentrations of PM10 and PM2.5 were relatively higher on platforms, inside subway carriages and in driver compartments than in the other areas monitored. The levels of PM10 and PM2.5 for station precincts and platforms exceeded the 24-h acceptable threshold limits of 150 microg/m3 for PM10 and 35 microg/m3 for PM2.5, which are regulated by the U.S. Environmental Protection Agency (EPA). However, levels measured in station and ticket offices fell below the respective threshold. The mean PM10 and PM2.5 concentrations on platforms located underground were significantly higher than those at ground level (p<0.05).

  5. Fire Perimeters

    Data.gov (United States)

    California Natural Resource Agency — The Fire Perimeters data consists of CDF fires 300 acres and greater in size and USFS fires 10 acres and greater throughout California from 1950 to 2003. Some fires...

  6. Fire History

    Data.gov (United States)

    California Natural Resource Agency — The Fire Perimeters data consists of CDF fires 300 acres and greater in size and USFS fires 10 acres and greater throughout California from 1950 to 2002. Some fires...

  7. Origin of inorganic and organic components of PM_2_._5 in subway stations of Barcelona, Spain

    International Nuclear Information System (INIS)

    Martins, Vânia; Moreno, Teresa; Minguillón, María Cruz; Drooge, Barend L. van; Reche, Cristina; Amato, Fulvio; Miguel, Eladio de; Capdevila, Marta; Centelles, Sonia; Querol, Xavier

    2016-01-01

    The present work assesses indoor air quality in stations of the Barcelona subway system. PM_2_._5 concentrations on the platforms of 4 subway stations were measured during two different seasons and the chemical composition was determined. A Positive Matrix Factorization analysis was performed to identify and quantify the contributions of major PM_2_._5 sources in the subway stations. Mean PM_2_._5 concentrations varied according to the stations design and seasonal periods. PM_2_._5 was composed of haematite, carbonaceous aerosol, crustal matter, secondary inorganic compounds, trace elements, insoluble sulphate and halite. Organic compounds such as PAHs, nicotine, levoglucosan and aromatic musk compounds were also identified. Subway PM_2_._5 source comprised emissions from rails, wheels, catenaries, brake pads and pantographs. The subway source showed different chemical profiles for each station, but was always dominated by Fe. Control actions on the source are important for the achievement of better air quality in the subway environment. - Highlights: • PM_2_._5 concentrations varied according to stations design and seasonal periods. • Haematite was the most abundant component of PM_2_._5. • Organic compounds such as PAHs were detected in the subway stations. • The subway contribution to ambient PM_2_._5 on the platforms ranged from 9 to 58%. • The chemical profile of the subway emissions varies depending on the station. - Concentrations of PM_2_._5 chemical components varied according to stations design, seasonal periods, and chemical composition of rail, catenary and trains. PM_2_._5 consists mainly of Fe.

  8. Subway particles are more genotoxic than street particles and induce oxidative stress in cultured human lung cells.

    Science.gov (United States)

    Karlsson, Hanna L; Nilsson, Lennart; Möller, Lennart

    2005-01-01

    Epidemiological studies have shown an association between airborne particles and a wide range of adverse health effects. The mechanisms behind these effects include oxidative stress and inflammation. Even though traffic gives rise to high levels of particles in the urban air, people are exposed to even higher levels in the subway. However, there is a lack of knowledge regarding how particles from different urban subenvironments differ in toxicity. The main aim of the present study was to compare the ability of particles from a subway station and a nearby very busy urban street, respectively, to damage DNA and to induce oxidative stress. Cultured human lung cells (A549) were exposed to particles, DNA damage was analyzed using single cell gel electrophoresis (the comet assay), and the ability to induce oxidative stress was measured as 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) formation in lung cell DNA. We found that the subway particles were approximately eight times more genotoxic and four times more likely to cause oxidative stress in the lung cells. When the particles, water extracts from the particles, or particles treated with the metal chelator deferoxamine mesylate were incubated with 2'-deoxyguanosine (dG) and 8-oxodG was analyzed, we found that the oxidative capacity of the subway particles was due to redox active solid metals. Furthermore, analysis of the atomic composition showed that the subway particles to a dominating degree (atomic %) consisted of iron, mainly in the form of magnetite (Fe3O4). By using electron microscopy, the interaction between the particles and the lung cells was shown. The in vitro reactivity of the subway particles in combination with the high particle levels in subway systems give cause of concern due to the high number of people that are exposed to subway particles on a daily basis. To what extent the subway particles cause health effects in humans needs to be further evaluated.

  9. Nuclear accidents

    International Nuclear Information System (INIS)

    1987-01-01

    On 27 May 1986 the Norwegian government appointed an inter-ministerial committee of senior officials to prepare a report on experiences in connection with the Chernobyl accident. The present second part of the committee's report describes proposals for measures to prevent and deal with similar accidents in the future. The committee's evaluations and proposals are grouped into four main sections: Safety and risk at nuclear power plants; the Norwegian contingency organization for dealing with nuclear accidents; compensation issues; and international cooperation

  10. The fire brigade renovates

    CERN Multimedia

    2002-01-01

    The new fire engine at CERN's Fire Station. A shiny brand-new fire engine is now attracting all the attention of the members of CERN's fire brigade. Since the beginning of last week this engine has taken over from an 18-year-old one, which has now been 'retired' from service. This modern vehicle, built in Brescia, Italy, is much lighter and more powerful than the old one and is equipped to allow the fire service to tackle most call-outs without the support of at least one other vehicle, as is currently necessary. The new fire engine is designed to transport six fire-fighters, 2000 litres of water, and is equipped not only for fire fighting actions but also to respond initially to any other kind of call-out, such as traffic accidents, chemical incidents, pollution, lightning, etc. It goes almost without saying that it is provided with the most modern safety measures, a low centre of gravity, as well as a special chassis and a combination pump (low and high pressure), which improve the safety and performance ...

  11. The French fire protection concept. Vulnerability analysis

    International Nuclear Information System (INIS)

    Kaercher, M.

    1998-01-01

    The French fire protection concept is based on a principle of three levels of defence in depth: fire prevention, fire containing and fire controlling. Fire prevention is based on arrangements which prevent the fire from starting or which make difficult for the fire to start. Fire containing is based on design measures so that the fire will have no impact on the safety of the installation. For fire controlling, equipment nad personnel are on duty in order to detect, to fight and to gain control over the fire as early as possible. The French fire protection concept gives priority to fire containing based on passive structural measures. All buildings containing safety equipment are divided into fire compartments (or fire areas) and fire cells (or fire zones). Basically, a compartment houses safety equipment belonging to one division (or train) so that the other division is always available to reach the plant safe shut down or to mitigate an accident. Because there is a large number of fire compartments and fire cells, deviations from the general principle can be observed. To this reason the RCC-I (Design and Construction Rules applicable for fire protection) requires to implement an assessment of the principle of division. This assessment is called vulnerability analysis. The vulnerability analysis is usually performed at the end of the project, before erection. It is also possible to perform a vulnerability analysis in an operating nuclear power plant in the scope of a fire safety upgrading programme. In the vulnerability analysis, the functional failure of all the equipment (except for those protected by a qualified fire barrier, designed or able to withstand the fire consequences) within the fire compartment or cell, where the fire breaks out, is postulated. The potential consequences for the plant safety are analysed

  12. Master equation approach to the intra-urban passenger flow and application to the Metropolitan Seoul Subway system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Keumsook [Department of Geography, Sungshin University, Seoul 136-742 (Korea, Republic of); Goh, Segun; Choi, M Y [Department of Physics and Astronomy and Center for Theoretical Physics, Seoul National University, Seoul 151-747 (Korea, Republic of); Park, Jong Soo [School of Information Technology, Sungshin University, Seoul 136-742 (Korea, Republic of); Jung, Woo-Sung, E-mail: kslee@sungshin.ac.kr, E-mail: mychoi@snu.ac.kr [Department of Physics and Basic Science Research Institute, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)

    2011-03-18

    The master equation approach is proposed to describe the evolution of passengers in a subway system. With the transition rate constructed from simple geographical consideration, the evolution equation for the distribution of subway passengers is found to bear skew distributions including log-normal, Weibull, and power-law distributions. This approach is then applied to the Metropolitan Seoul Subway system: analysis of the trip data of all passengers in a day reveals that the data in most cases fit well to the log-normal distributions. Implications of the results are also discussed.

  13. Master equation approach to the intra-urban passenger flow and application to the Metropolitan Seoul Subway system

    International Nuclear Information System (INIS)

    Lee, Keumsook; Goh, Segun; Choi, M Y; Park, Jong Soo; Jung, Woo-Sung

    2011-01-01

    The master equation approach is proposed to describe the evolution of passengers in a subway system. With the transition rate constructed from simple geographical consideration, the evolution equation for the distribution of subway passengers is found to bear skew distributions including log-normal, Weibull, and power-law distributions. This approach is then applied to the Metropolitan Seoul Subway system: analysis of the trip data of all passengers in a day reveals that the data in most cases fit well to the log-normal distributions. Implications of the results are also discussed.

  14. Analysis of economic feasibility of opening a franchise Subway in Crimea

    OpenAIRE

    Tsoy, Nataly

    2014-01-01

    In article analysis the state of the modern fast-food market in Russian Federation. The author observes main trends in this area, the competitiveness of the different regions of the country. The special attention is given to the proposal of opening Subway franchise in the Crimea

  15. Urban air quality comparison for bus, tram, subway and pedestrian commutes in Barcelona.

    Science.gov (United States)

    Moreno, Teresa; Reche, Cristina; Rivas, Ioar; Cruz Minguillón, Maria; Martins, Vânia; Vargas, Concepción; Buonanno, Giorgio; Parga, Jesus; Pandolfi, Marco; Brines, Mariola; Ealo, Marina; Sofia Fonseca, Ana; Amato, Fulvio; Sosa, Garay; Capdevila, Marta; de Miguel, Eladio; Querol, Xavier; Gibbons, Wes

    2015-10-01

    Access to detailed comparisons in air quality variations encountered when commuting through a city offers the urban traveller more informed choice on how to minimise personal exposure to inhalable pollutants. In this study we report on an experiment designed to compare atmospheric contaminants inhaled during bus, subway train, tram and walking journeys through the city of Barcelona. Average number concentrations of particles 10-300 nm in size, N, are lowest in the commute using subway trains (N5.0×10(4) cm(-3)), with extreme transient peaks at busy traffic crossings commonly exceeding 1.0×10(5) cm(-3) and accompanied by peaks in Black Carbon and CO. Subway particles are coarser (mode 90 nm) than in buses, trams or outdoors (1200 ppm in crowded buses and trains. There are also striking differences in inhalable particle chemistry depending on the route chosen, ranging from aluminosiliceous at roadsides and near pavement works, ferruginous with enhanced Mn, Co, Zn, Sr and Ba in the subway environment, and higher levels of Sb and Cu inside the bus. We graphically display such chemical variations using a ternary diagram to emphasise how "air quality" in the city involves a consideration of both physical and chemical parameters, and is not simply a question of measuring particle number or mass. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Empirical approach for real-time estimation of air flow rates in a subway station

    OpenAIRE

    Di Perna, Costanzo; Carbonari, Alessandro; Ansuini, Roberta; Casals Casanova, Miquel

    2014-01-01

    The EU-funded project called SEAM4US (Sustainable Energy mAnageMent for Underground Stations) is targeted to define advanced control systems for cost-effective management of subway stations, which will be applied to the pilot Peer Reviewed

  17. Air pollution and activity during transportation by car, subway, and walking.

    Science.gov (United States)

    Morabia, Alfredo; Amstislavski, Philippe N; Mirer, Franklin E; Amstislavski, Tashia M; Eisl, Holger; Wolff, Mary S; Markowitz, Steven B

    2009-07-01

    Little evidence exists about the health risks and benefits associated with using public buses and subways rather than cars. The objective of the current study was to assess the magnitude and variance of personal exposure to particulate matter 2.5 microns or smaller (PM(2.5)) and concomitant physical activity energy expenditure (PAEE) for transportation by car, subway, or walking. Twenty nonsmoking volunteers from New York City traveled on predetermined routes by car, subway, and walking, for up to 8 hours on 3 different days, between October 2007 and February 2008. Outfitted with a personal monitor with PM(2.5) aerosol inlet, and a GPS receiver, they completed a detailed physical activity diary for each route. Both metabolic equivalent (MET) and PAEE rates (Kcal/min) were computed from GPS-derived activity durations and speeds, activity-specific METs, and measured body weight. Total PM(2.5) exposures did not differ among car, subway, and walking arms (respectively, 21.4, 30.6, and 26.5 microg/m(3) x min, p=0.19); but average MET values (respectively, 1.51, 2.03, and 2.60 Kcal/kg x hr, ptransportation.

  18. SIRS Model of Passengers’ Panic Propagation under Self-Organization Circumstance in the Subway Emergency

    Directory of Open Access Journals (Sweden)

    Haifeng Zhao

    2014-01-01

    Full Text Available Subway emergency may lead to passengers’ panic, especially under self-organizing circumstance, which will spread rapidly and have an adverse impact on the society. This paper builds an improved SIRS model of passengers’ panic spread in subway emergency with consideration of passengers’ density, the characteristic of subway car with the confined space, and passengers’ psychological factors. The spread of passengers’ panic is simulated by use of Matlab, which draws the rules of how group panic spreads dynamically. The trend of stable point of the infection ratio is analyzed by changing different parameters, which help to draw a conclusion that immunization rate, spontaneous immune loss rate, and passenger number have a great influence on the final infected ratio. Finally, we propose an integrated control strategy and find the peak of passengers’ panic and the final infected ratio is greatly improved through the numerical simulation. The research plays a vital role in helping the government and subway administration to master the panic spread mechanism and reduce the panic spread by improving measures and also provides certain reference significance for rail system construction, emergency contingency plans, and the construction and implementation of emergency response system.

  19. DISTURBANCES IN THE POWER SUPPLY NETWORK OF BUCHAREST SUBWAY SYSTEM (PART 1

    Directory of Open Access Journals (Sweden)

    Alexandru Ionuț CHIUȚĂ

    2011-05-01

    Full Text Available In the present study it is exposed the problem of disturbances in the main power supply of Bucharest Subway (underground system, the cause and their action, as well as the measures taken to limit the disturbances produced. All this is reflected in the measurements made using oscilloscope Fluke installed at the dispatch point, following to be then processed.

  20. Building damage related to Amsterdam subway : Comparison of traditional monitoring with satellite monitoring results

    NARCIS (Netherlands)

    Korff, M.; Maccabiani, J

    2017-01-01

    This paper describes the evaluation of the monitoring data obtained from the construction of the North/South Line, a new subway line crossing the historic center of Amsterdam. During construction of the line (2003-2014), building deformations were monitored with Robotic Total Stations and with

  1. Cycling for Transportation in Sao Paulo City: Associations with Bike Paths, Train and Subway Stations.

    Science.gov (United States)

    Florindo, Alex Antonio; Barrozo, Ligia Vizeu; Turrell, Gavin; Barbosa, João Paulo Dos Anjos Souza; Cabral-Miranda, William; Cesar, Chester Luiz Galvão; Goldbaum, Moisés

    2018-03-21

    Cities that support cycling for transportation reap many public health benefits. However, the prevalence of this mode of transportation is low in Latin American countries and the association with facilities such as bike paths and train/subway stations have not been clarified. We conducted a cross-sectional analysis of the relationship between bike paths, train/subway stations and cycling for transportation in adults from the city of Sao Paulo. We used data from the Sao Paulo Health Survey ( n = 3145). Cycling for transportation was evaluated by a questionnaire and bike paths and train/subway stations were geocoded using the geographic coordinates of the adults' residential addresses in 1500-m buffers. We used multilevel logistic regression, taking account of clustering by census tract and households. The prevalence of cycling for transportation was low (5.1%), and was more prevalent in males, singles, those active in leisure time, and in people with bicycle ownership in their family. Cycling for transportation was associated with bike paths up to a distance of 500 m from residences (OR (Odds Ratio) = 2.54, 95% CI (Confidence interval) 1.16-5.54) and with the presence of train/subway stations for distances >500 m from residences (OR = 2.07, 95% CI 1.10-3.86). These results are important to support policies to improve cycling for transportation in megacities such as Sao Paulo.

  2. Noise pollution survey of a two-storey intersection station in Tehran metropolitan subway system.

    Science.gov (United States)

    Ghotbi, Mohammad Reza; Monazzam, Mohammad Reza; Baneshi, Mohammad Reza; Asadi, Mohammad; Fard, Samaneh Momen Bellah

    2012-01-01

    According to the world population increase and demand on transportation in mega cities, modern and low-cost technologies are remarkably considered. Meanwhile, subway system, as a means to transfer a large population of people, is extremely welcomed due to its particular advantages including time and cost savings, traffic jam avoidance, and unaffected by weather. Nevertheless, despite the benefits of these technologies, such devices also have been associated with disadvantages for human. In many subway systems, noisy environments are clearly observed; therefore, workers and even the passengers are exposed to higher noise levels than permissible limit. In this research, noise measurements were performed at Imam Khomeini Station as the most crowded intersection subway station in Tehran. In this descriptive-sectional survey, the amount of noise pollution was investigated at both stories of Imam Khomeini Intersection Station. A variety of noise pollution indicators such as L(eq) 10 min were separately measured at each storey through five measurement points from 7 A.M. to 10 P.M. It was shown that the equivalent sound level range at Imam Khomeini station towards Elmo Sanat and Imam Khomeini towards Mirdamad were between 70.56-79.54 and 68.35-79.12 dB (A), respectively. It was indicated that except for the entrance stairs to the subway waiting platform and the first section of the platform on both stories, other measurement stations have the same equivalent sound levels.

  3. The Underground Economy: Tracking the Wider Impacts of the São Paulo Subway System

    NARCIS (Netherlands)

    Haddad, E.A.; Hewings, G.J.D.; Porsse, A.A.; van Leeuwen, E.S.; Vieira, R.S.

    2015-01-01

    Over one million workers commute daily to São Paulo City center, using different modes of transportation. The São Paulo subway network reaches 74.2. km of length and is involved in around 20% of the commuting trips by public transportation, enhancing mobility and productivity of workers. This paper

  4. Managing Recurrent Congestion of Subway Network in Peak Hours with Station Inflow Control

    Directory of Open Access Journals (Sweden)

    Qingru Zou

    2018-01-01

    Full Text Available Station inflow control (SIC is an important and effective method for reducing recurrent congestion during peak hours in the Beijing, Shanghai, and Guangzhou subway systems. This work proposes a practical and efficient method for establishing a static SIC scheme in normal weekdays for large-scale subway networks. First, a traffic assignment model without capacity constraint is utilized to determine passenger flow distributions on the network. An internal relationship between station inflows and section flows is then constructed. Second, capacity bottlenecks are identified by considering the transport capacity of each section. Then, a feedback-based bottleneck elimination strategy is established to search target control stations and determine their control time and control strength. To validate the effectiveness of the proposed approach, a decision support system coded in the C# programming language was developed, and the Beijing subway was used as a case study. The results indicate that the proposed method and tool are capable of practical applications, and the generated SIC plan has better performance over the existing SIC plan. This study provides a practical and useful method for operation agencies to construct SIC schemes in the subway system.

  5. Characteristics of the elemental compositions of particulate matter at a subway platform using INAA and XRF

    Energy Technology Data Exchange (ETDEWEB)

    Lim, J.M.; Moon, J.H.; Chung, Y.S. [Korea Atomic Energy Research Insitute, Daejeon (Korea, Republic of). Dept. of Nuclear Basic Science; Jeong, J.H.; Jung, B.W.; Lee, J.H. [Chungnam National Univ., Daejeon (Korea, Republic of). Dept. of Environmental Engineering; Kim, K.H. [Sejong Univ., Seoul (Korea, Republic of). Dept. of Environment and Energy

    2011-07-01

    In this study, a total of 21 elements were determined from PM2.5 and PM10 samples collected at one subway station using INAA and XRF. In order to assess the pollution status and distribution characteristics in a subway station, the absolute concentration levels, concentration ratios, and crustal enrichment factors of these elements were analyzed. PM2.5 concentrations in the subway station varied in the range of 24.8 to 72.6 {mu}g m{sup -3} (average {+-} standard deviation: 42.6{+-}10.6 {mu}g m{sup -3}), while those of PM10 from 38.0 to 101 {mu}g m{sup -3} (67.2{+-}15.5 {mu}g m{sup -3}). The relative contribution of elemental components in each particle fraction accounted for about 42 and 44%, respectively. Out of all metals, Fe was predominant to represent about 29 and 27% of each particle fraction. In contrast, the crustal sources were estimated to contribute to about 3.7 and 2.3% of the total Fe concentrations, respectively. Thus, one can conclude that considerable quantities of airborne Fe particles originated mainly from subway sources, probably due to the wearing of the steel products like wheel, rail, brake, etc. (orig.)

  6. Music as Transitional Object and Practice: Children's Spontaneous Musical Behaviors in the Subway

    Science.gov (United States)

    Custodero, Lori A.; Calì, Claudia; Diaz-Donoso, Adriana

    2016-01-01

    This study looks at children's music making in a public setting designed for society writ large. Although known to most children in the city, the subway presents a unique environment, both structurally predictable yet sonically dynamic; it is in continuous transition. Adopting Winnicott's psychoanalytical perspective, we make a case for viewing…

  7. Characteristics of the elemental compositions of particulate matter at a subway platform using INAA and XRF

    International Nuclear Information System (INIS)

    Lim, J.M.; Moon, J.H.; Chung, Y.S.; Jeong, J.H.; Jung, B.W.; Lee, J.H.; Kim, K.H.

    2011-01-01

    In this study, a total of 21 elements were determined from PM2.5 and PM10 samples collected at one subway station using INAA and XRF. In order to assess the pollution status and distribution characteristics in a subway station, the absolute concentration levels, concentration ratios, and crustal enrichment factors of these elements were analyzed. PM2.5 concentrations in the subway station varied in the range of 24.8 to 72.6 μg m -3 (average ± standard deviation: 42.6±10.6 μg m -3 ), while those of PM10 from 38.0 to 101 μg m -3 (67.2±15.5 μg m -3 ). The relative contribution of elemental components in each particle fraction accounted for about 42 and 44%, respectively. Out of all metals, Fe was predominant to represent about 29 and 27% of each particle fraction. In contrast, the crustal sources were estimated to contribute to about 3.7 and 2.3% of the total Fe concentrations, respectively. Thus, one can conclude that considerable quantities of airborne Fe particles originated mainly from subway sources, probably due to the wearing of the steel products like wheel, rail, brake, etc. (orig.)

  8. Managing severe reactor accidents. A review and evaluation of our knowledge on reactor accidents and accident management

    International Nuclear Information System (INIS)

    Gustavsson, Veine

    2002-11-01

    The report gives a review of the results from the last years research on severe reactor accidents, and an opinion on the possibilities to refine the present strategies for accident management in Swedish and Finnish BWRs. The following aspect of reactor accidents are the major themes of the study: 1. Early pressure relief from hydrogen production; 2. Recriticality in re-flooded, degraded core; 3. Melt-through; 4. Steam explosion after melt-through; 5. Coolability of the melt after after melt-through; 6. Hydrogen fire in the reactor containment; 7. Leaking containment; 8. Hydrogen fire in the reactor building; 9. Long-time developments after a severe accident; 10. Accidents during shutdown for overhaul; 11. Information need for remedial actions. Possibilities for improving the strategies in each of these areas are discussed. The review shows that our knowledge is sufficient in the areas 1, 2, 4, 6, 8. For the other areas, more research is needed

  9. Nuclear ship accidents

    International Nuclear Information System (INIS)

    Oelgaard, P.L.

    1993-05-01

    In this report available information on 28 nuclear ship accident and incidents is considered. Of these 5 deals with U.S. ships and 23 with USSR ships. The ships are in almost all cases nuclear submarines. Only events that involve the nuclear propulsion plants, radiation exposures, fires/explosions and sea water leaks into the submarines are considered. Comments are made on each of the events, and at the end of the report an attempt is made to point out the weaknesses of the submarine designs which have resulted in the accidents. It is emphasized that much of the available information is of a rather dubious nature. consequently some of the assessments made may not be correct. (au)

  10. Asthmatics exhibit altered oxylipin profiles compared to healthy individuals after subway air exposure.

    Directory of Open Access Journals (Sweden)

    Susanna L Lundström

    Full Text Available Asthma is a chronic inflammatory lung disease that causes significant morbidity and mortality worldwide. Air pollutants such as particulate matter (PM and oxidants are important factors in causing exacerbations in asthmatics, and the source and composition of pollutants greatly affects pathological implications.This randomized crossover study investigated responses of the respiratory system to Stockholm subway air in asthmatics and healthy individuals. Eicosanoids and other oxylipins were quantified in the distal lung to provide a measure of shifts in lipid mediators in association with exposure to subway air relative to ambient air.Sixty-four oxylipins representing the cyclooxygenase (COX, lipoxygenase (LOX and cytochrome P450 (CYP metabolic pathways were screened using liquid chromatography-tandem mass spectrometry (LC-MS/MS of bronchoalveolar lavage (BAL-fluid. Validations through immunocytochemistry staining of BAL-cells were performed for 15-LOX-1, COX-1, COX-2 and peroxisome proliferator-activated receptor gamma (PPARγ. Multivariate statistics were employed to interrogate acquired oxylipin and immunocytochemistry data in combination with patient clinical information.Asthmatics and healthy individuals exhibited divergent oxylipin profiles following exposure to ambient and subway air. Significant changes were observed in 8 metabolites of linoleic- and α-linolenic acid synthesized via the 15-LOX pathway, and of the COX product prostaglandin E(2 (PGE(2. Oxylipin levels were increased in healthy individuals following exposure to subway air, whereas asthmatics evidenced decreases or no change.Several of the altered oxylipins have known or suspected bronchoprotective or anti-inflammatory effects, suggesting a possible reduced anti-inflammatory response in asthmatics following exposure to subway air. These observations may have ramifications for sensitive subpopulations in urban areas.

  11. Asthmatics exhibit altered oxylipin profiles compared to healthy individuals after subway air exposure.

    Science.gov (United States)

    Lundström, Susanna L; Levänen, Bettina; Nording, Malin; Klepczynska-Nyström, Anna; Sköld, Magnus; Haeggström, Jesper Z; Grunewald, Johan; Svartengren, Magnus; Hammock, Bruce D; Larsson, Britt-Marie; Eklund, Anders; Wheelock, Åsa M; Wheelock, Craig E

    2011-01-01

    Asthma is a chronic inflammatory lung disease that causes significant morbidity and mortality worldwide. Air pollutants such as particulate matter (PM) and oxidants are important factors in causing exacerbations in asthmatics, and the source and composition of pollutants greatly affects pathological implications. This randomized crossover study investigated responses of the respiratory system to Stockholm subway air in asthmatics and healthy individuals. Eicosanoids and other oxylipins were quantified in the distal lung to provide a measure of shifts in lipid mediators in association with exposure to subway air relative to ambient air. Sixty-four oxylipins representing the cyclooxygenase (COX), lipoxygenase (LOX) and cytochrome P450 (CYP) metabolic pathways were screened using liquid chromatography-tandem mass spectrometry (LC-MS/MS) of bronchoalveolar lavage (BAL)-fluid. Validations through immunocytochemistry staining of BAL-cells were performed for 15-LOX-1, COX-1, COX-2 and peroxisome proliferator-activated receptor gamma (PPARγ). Multivariate statistics were employed to interrogate acquired oxylipin and immunocytochemistry data in combination with patient clinical information. Asthmatics and healthy individuals exhibited divergent oxylipin profiles following exposure to ambient and subway air. Significant changes were observed in 8 metabolites of linoleic- and α-linolenic acid synthesized via the 15-LOX pathway, and of the COX product prostaglandin E(2) (PGE(2)). Oxylipin levels were increased in healthy individuals following exposure to subway air, whereas asthmatics evidenced decreases or no change. Several of the altered oxylipins have known or suspected bronchoprotective or anti-inflammatory effects, suggesting a possible reduced anti-inflammatory response in asthmatics following exposure to subway air. These observations may have ramifications for sensitive subpopulations in urban areas.

  12. Modelling the Shifts in Activity Centres along the Subway Stations. The Case Study of Metropolitan Tehran

    Directory of Open Access Journals (Sweden)

    Ali Soltani

    2016-10-01

    Full Text Available Activity centers are areas of strong development of a particular activity, such as residence, employment, or services. Understanding the subway system impacts on the type, combination, distribution and totally the development of basic activities in these centers, have an important role in managing development opportunities created along the Tehran subway lines. The multi criteria and fuzzy nature of evaluating the activity centers development make the issue as complex as cannot be addressed with conventional logical systems. One of the most important methods of multi criteria evaluation is Fuzzy Inference System. Fuzzy inference system is a popular computing framework based on the concepts of Fuzzy Sets Theory, which is capable of accommodating inherent uncertainty in multi-criteria evaluation process. This paper analyze shifts in activity centers along two lines of the Tehran subway system based on three major criteria by designing a comprehensive fuzzy inference system. The data for the present study were collected through documentary analysis, questionnaires and semi-structured interview. The result revealed that the level of the subway system influence on the pattern and process of the development of activities varied with the location, physical environment and entity of each station. Furthermore, empirical findings indicated that the subway line might weaken residential activities while attracting employment and service activities to the city center. Specifically, residential estates moved away from the city center to the suburbs whereas employment and service activities expanded from the existing central business district (CBD. The results can be applied to suggest planning policies aiming at improving the effects of public transit on property developemnet and land use change in a developing country.

  13. Analysis of credible accidents for Argonaut reactors. Report for October 1980-April 1981

    International Nuclear Information System (INIS)

    Hawley, S.C.; Kathren, R.L.; Robkin, M.A.

    1981-04-01

    Five areas of potential accidents have been evaluated for the Argonaut-UTR reactors. They are: insertion of excess reactivity, catastrophic rearrangement of the core, explosive chemical reaction, graphite fire, and a fuel-handling accident

  14. Truck accident involving unirradiated nuclear fuel

    International Nuclear Information System (INIS)

    Carlson, R.W.; Fischer, L.E.

    1992-07-01

    In the early morning of Dec. 16, 1991, a severe accident occurred when a passenger vehicle traveling in the wrong direction collided with a tractor trailer carrying 24 nuclear fuel assemblies in 12 containers on Interstate 1-91 in Springfield, Massachusetts. This paper documents the mechanical circumstances of the accident and the physical environment to which the containers were exposed and the response of the containers and their contents. The accident involved four impacts where the truck was struck by the car, impacted on the center guardrail, impacted on the outer concrete barrier and came to rest against the center guardrail. The impacts were followed by a fire that began in the engine compartment, spread to the.tractor and cab, and eventually spread to the trailer and payload. The fire lasted for about three hours and the packages were involved in the fire for about two hours. As a result of the fire, the tractor-trailer was completely destroyed and the packages were exposed to flames with temperatures between 1300 degrees F and 1800 degrees F. The fuel assemblies remained intact during the accident and there was no release of any radioactive material during the accident. This was a very severe accident; however, the injuries were minor and at no time was the public health and safety at risk

  15. Truck accident involving unirradiated nuclear fuel

    International Nuclear Information System (INIS)

    Carlson, R.W.; Fischer, L.E.

    1993-01-01

    In the early morning of Dec. 16, 1991, a severe accident occurred when a passenger vehicle traveling in the wrong direction collided with a tractor trailer carrying 24 unirradiated nuclear fuel assemblies in 12 containers on Interstate I-91 in Springfield, Massachusetts. This paper documents the mechanical circumstances of the accident and assesses the physical environment to which the containers were exposed and the response of the containers and their contents. The accident involved four impacts where the truck was struck by the car, impacted on the center guardrail, impacted on the outer concrete barrier and came to rest against the center guardrail. The impacts were followed by a fire that began in the engine compartment, spread to the tractor and cab, and eventually spread to the trailer and payload. The fire lasted for about three hours and the packages were involved in the fire for about two hours. As a result of the fire, the tractor-trailer was completely destroyed and the packages were exposed to flames with temperatures between 1,300 F and 1,800 F. The fuel assemblies remained intact during the accident and there was no release of any radioactive material during the accident. This was a very severe accident; however, the injuries were minor and at no time was the public health and safety at risk

  16. Normal accidents

    International Nuclear Information System (INIS)

    Perrow, C.

    1989-01-01

    The author has chosen numerous concrete examples to illustrate the hazardousness inherent in high-risk technologies. Starting with the TMI reactor accident in 1979, he shows that it is not only the nuclear energy sector that bears the risk of 'normal accidents', but also quite a number of other technologies and industrial sectors, or research fields. The author refers to the petrochemical industry, shipping, air traffic, large dams, mining activities, and genetic engineering, showing that due to the complexity of the systems and their manifold, rapidly interacting processes, accidents happen that cannot be thoroughly calculated, and hence are unavoidable. (orig./HP) [de

  17. Industrial accidents triggered by lightning.

    Science.gov (United States)

    Renni, Elisabetta; Krausmann, Elisabeth; Cozzani, Valerio

    2010-12-15

    Natural disasters can cause major accidents in chemical facilities where they can lead to the release of hazardous materials which in turn can result in fires, explosions or toxic dispersion. Lightning strikes are the most frequent cause of major accidents triggered by natural events. In order to contribute towards the development of a quantitative approach for assessing lightning risk at industrial facilities, lightning-triggered accident case histories were retrieved from the major industrial accident databases and analysed to extract information on types of vulnerable equipment, failure dynamics and damage states, as well as on the final consequences of the event. The most vulnerable category of equipment is storage tanks. Lightning damage is incurred by immediate ignition, electrical and electronic systems failure or structural damage with subsequent release. Toxic releases and tank fires tend to be the most common scenarios associated with lightning strikes. Oil, diesel and gasoline are the substances most frequently released during lightning-triggered Natech accidents. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Origin of inorganic and organic components of PM2.5 in subway stations of Barcelona, Spain.

    Science.gov (United States)

    Martins, Vânia; Moreno, Teresa; Minguillón, María Cruz; van Drooge, Barend L; Reche, Cristina; Amato, Fulvio; de Miguel, Eladio; Capdevila, Marta; Centelles, Sonia; Querol, Xavier

    2016-01-01

    The present work assesses indoor air quality in stations of the Barcelona subway system. PM2.5 concentrations on the platforms of 4 subway stations were measured during two different seasons and the chemical composition was determined. A Positive Matrix Factorization analysis was performed to identify and quantify the contributions of major PM2.5 sources in the subway stations. Mean PM2.5 concentrations varied according to the stations design and seasonal periods. PM2.5 was composed of haematite, carbonaceous aerosol, crustal matter, secondary inorganic compounds, trace elements, insoluble sulphate and halite. Organic compounds such as PAHs, nicotine, levoglucosan and aromatic musk compounds were also identified. Subway PM2.5 source comprised emissions from rails, wheels, catenaries, brake pads and pantographs. The subway source showed different chemical profiles for each station, but was always dominated by Fe. Control actions on the source are important for the achievement of better air quality in the subway environment. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Chemical speciation of size-segregated floor dusts and airborne magnetic particles collected at underground subway stations in Seoul, Korea.

    Science.gov (United States)

    Jung, Hae-Jin; Kim, BoWha; Malek, Md Abdul; Koo, Yong Sung; Jung, Jong Hoon; Son, Youn-Suk; Kim, Jo-Chun; Kim, HyeKyoung; Ro, Chul-Un

    2012-04-30

    Previous studies have reported the major chemical species of underground subway particles to be Fe-containing species that are generated from wear and friction processes at rail-wheel-brake and catenaries-pantographs interfaces. To examine chemical composition of Fe-containing particles in more details, floor dusts were collected at five sampling locations of an underground subway station. Size-segregated floor dusts were separated into magnetic and non-magnetic fractions using a permanent magnet. Using X-ray diffraction (XRD) and scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDX), iron metal, which is relatively harmless, was found to be the dominating chemical species in the floor dusts of the subway stations can be controlled by removing magnetic indoor particles using magnets. In addition, airborne subway particles, most of which were smaller than 10 μm, were collected using permanent magnets at two underground subway stations, namely Jegi and Yangjae stations, in Seoul, Korea. XRD and SEM/EDX analyses showed that most of the magnetic aerosol particles collected at Jegi station was iron metal, whereas those at Yangjae station contained a small amount of Fe mixed with Na, Mg, Al, Si, S, Ca, and C. The difference in composition of the Fe-containing particles between the two subway stations was attributed to the different ballast tracks used. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Estimation of inhaled airborne particle number concentration by subway users in Seoul, Korea

    International Nuclear Information System (INIS)

    Kim, Minhae; Park, Sechan; Namgung, Hyeong-Gyu; Kwon, Soon-Bark

    2017-01-01

    Exposure to airborne particulate matter (PM) causes several diseases in the human body. The smaller particles, which have relatively large surface areas, are actually more harmful to the human body since they can penetrate deeper parts of the lungs or become secondary pollutants by bonding with other atmospheric pollutants, such as nitrogen oxides. The purpose of this study is to present the number of PM inhaled by subway users as a possible reference material for any analysis of the hazards to the human body arising from the inhalation of such PM. Two transfer stations in Seoul, Korea, which have the greatest number of users, were selected for this study. For 0.3–0.422 μm PM, particle number concentration (PNC) was highest outdoors but decreased as the tester moved deeper underground. On the other hand, the PNC between 1 and 10 μm increased as the tester moved deeper underground and showed a high number concentration inside the subway train as well. An analysis of the particles to which subway users are actually exposed to (inhaled particle number), using particle concentration at each measurement location, the average inhalation rate of an adult, and the average stay time at each location, all showed that particles sized 0.01–0.422 μm are mostly inhaled from the outdoor air whereas particles sized 1–10 μm are inhaled as the passengers move deeper underground. Based on these findings, we expect that the inhaled particle number of subway users can be used as reference data for an evaluation of the hazards to health caused by PM inhalation. - Highlights: • Size-dependent aerosol number was measured along the path of subway user. • Particles less than 0.4 μm were inhaled in outdoor but less so as deeper underground. • Coarse particles were inhaled significantly as users moved deeper underground. - We estimated the inhaled aerosol number concentration depending on particle size along the path of subway users.

  1. Accident Statistics

    Data.gov (United States)

    Department of Homeland Security — Accident statistics available on the Coast Guard’s website by state, year, and one variable to obtain tables and/or graphs. Data from reports has been loaded for...

  2. Radiation accidents

    International Nuclear Information System (INIS)

    Nenot, J.C.

    1996-01-01

    Analysis of radiation accidents over a 50 year period shows that simple cases, where the initiating events were immediately recognised, the source identified and under control, the medical input confined to current handling, were exceptional. In many cases, the accidents were only diagnosed when some injuries presented by the victims suggested the radiological nature of the cause. After large-scale accidents, the situation becomes more complicated, either because of management or medical problems, or both. The review of selected accidents which resulted in severe consequences shows that most of them could have been avoided; lack of regulations, contempt for rules, human failure and insufficient training have been identified as frequent initiating parameters. In addition, the situation was worsened because of unpreparedness, insufficient planning, unadapted resources, and underestimation of psychosociological aspects. (author)

  3. Reactor accidents and the actions of fire brigades. Plea for nuclear phaseout. An analytic report on Leipzig, Windscale, Chernobyl and Fukushima; Reaktorunfaelle und die Handlungen der Feuerwehr. Plaedoyer fuer den Atomausstieg. Ein Analysebericht zu Leipzig, Windscale, Tschernobyl und Fukushima

    Energy Technology Data Exchange (ETDEWEB)

    Steffler, Reinhard

    2016-11-01

    The report covers the historically first fire brigade action at the ''uranium machine'' on June 23th 1942 in Leipzig, and the fire brigade actions in Windscale (October 11, 1957), Chernobyl and Fukushima Daiichi. Further issues are the behavior of the media, selected features of the fire brigade actions, and a discussion of questions concerning the preparedness of the fire brigades.

  4. Sports Accidents

    CERN Multimedia

    Kiebel

    1972-01-01

    Le Docteur Kiebel, chirurgien à Genève, est aussi un grand ami de sport et de temps en temps médecin des classes genevoises de ski et également médecin de l'équipe de hockey sur glace de Genève Servette. Il est bien qualifié pour nous parler d'accidents de sport et surtout d'accidents de ski.

  5. Radiation accidents

    International Nuclear Information System (INIS)

    Poplavskij, K.K.; Smorodintseva, G.I.

    1978-01-01

    On the basis of a critical analysis of the available data on causes and consequences of radiation accidents (RA), a classification of RA by severity (five groups of accidents) according to biomedical consequences and categories of exposed personnel is proposed. A RA is defined and its main characteristics are described. Methods of RA prevention are proposed, as is a plan of specific measures to deal with RA in accordance with the proposed classification

  6. Iron speciation of airborne subway particles by the combined use of energy dispersive electron probe X-ray microanalysis and Raman microspectrometry.

    Science.gov (United States)

    Eom, Hyo-Jin; Jung, Hae-Jin; Sobanska, Sophie; Chung, Sang-Gwi; Son, Youn-Suk; Kim, Jo-Chun; Sunwoo, Young; Ro, Chul-Un

    2013-11-05

    Quantitative energy-dispersive electron probe X-ray microanalysis (ED-EPMA), known as low-Z particle EPMA, and Raman microspectrometry (RMS) were applied in combination for an analysis of the iron species in airborne PM10 particles collected in underground subway tunnels. Iron species have been reported to be a major chemical species in underground subway particles generated mainly from mechanical wear and friction processes. In particular, iron-containing particles in subway tunnels are expected to be generated with minimal outdoor influence on the particle composition. Because iron-containing particles have different toxicity and magnetic properties depending on their oxidation states, it is important to determine the iron species of underground subway particles in the context of both indoor public health and control measures. A recently developed analytical methodology, i.e., the combined use of low-Z particle EPMA and RMS, was used to identify the chemical species of the same individual subway particles on a single particle basis, and the bulk iron compositions of airborne subway particles were also analyzed by X-ray diffraction. The majority of airborne subway particles collected in the underground tunnels were found to be magnetite, hematite, and iron metal. All the particles collected in the tunnels of underground subway stations were attracted to permanent magnets due mainly to the almost ubiquitous ferrimagnetic magnetite, indicating that airborne subway particles can be removed using magnets as a control measure.

  7. Radon exposure assessment for underground workers: a case of Seoul Subway Police officers in Korea.

    Science.gov (United States)

    Song, Myeong Han; Chang, Byung-Uck; Kim, Yongjae; Cho, Kun-Woo

    2011-11-01

    The objective of this study is the systematic and individual assessment of the annual effective dose due to inhaled radon for the Seoul Subway Police officers, Korea. The annual average radon concentrations were found to be in the range of 18.9-114 Bq·m(-3) in their workplaces. The total annual effective doses which may likely to be received on duty were assessed to be in the range of 0.41-1.64 mSv·y(-1). These were well below the recommended action level 10 mSv·y(-1) by ICRP. However, the effective doses were higher than subway station staff in Seoul, Korea.

  8. Modification of the gravity model and application to the metropolitan Seoul subway system.

    Science.gov (United States)

    Goh, Segun; Lee, Keumsook; Park, Jong Soo; Choi, M Y

    2012-08-01

    The Metropolitan Seoul Subway system is examined through the use of the gravity model. Exponents describing the power-law dependence on the time distance between stations are obtained, which reveals a universality for subway lines of the same topology. In the short (time) distance regime the number of passengers between stations does not grow with the decrease in the distance, thus deviating from the power-law behavior. It is found that such reduction in passengers is well described by the Hill function. Further, temporal fluctuations in the passenger flow data, fitted to the gravity model modified by the Hill function, are analyzed to reveal the Yule-type nature inherent in the structure of Seoul.

  9. Research on Energy-Saving Operation Strategy for Multiple Trains on the Urban Subway Line

    Directory of Open Access Journals (Sweden)

    Jianqiang Liu

    2017-12-01

    Full Text Available Energy consumption for multiple trains on the urban subway line is predominantly affected by the operation strategy. This paper proposed an energy-saving operation strategy for multiple trains, which is suitable for various line conditions and complex train schedules. The model and operation modes of the strategy are illustrated in detail, aiming to take full use of regenerative braking energy in complex multi-train systems with different departure intervals and dwell times. The computing method is proposed by means of the heuristic algorithm to obtain the optimum operation curve for each train. The simulation result based on a real urban subway line is provided to verify the correctness and effectiveness of the proposed energy-saving operation strategy.

  10. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Analysis of core damage frequency from internal fire events for Plant Operational State 5 during a refueling outage. Volume 3

    International Nuclear Information System (INIS)

    Lambright, J.; Yakle, J.

    1994-07-01

    This report, Volume 3, presents the details of the analysis of core damage frequency due to fire during shutdown Plant Operational State 5 at the Grand Gulf Nuclear Station. Insights from previous fire analyses (Peach Bottom, Surry, LaSalle) were used to the greatest extent possible in this analysis. The fire analysis was fully integrated utilizing the same event trees and fault trees that were used in the internal events analysis. In assessing shutdown risk due to fire at Grand Gulf, a detailed screening was performed which included the following elements: (a) Computer-aided vital area analysis; (b) Plant inspections; (c) Credit for automatic fire protection systems; (d) Recovery of random failures; (e) Detailed fire propagation modeling. This screening process revealed that all plant areas had a negligible (<1.0E-8 per year) contribution to fire-induced core damage frequency

  11. Multi-approach analysis of maximum riverbed scour depth above subway tunnel

    OpenAIRE

    Jun Chen; Hong-wu Tang; Zui-sen Li; Wen-hong Dai

    2010-01-01

    When subway tunnels are routed underneath rivers, riverbed scour may expose the structure, with potentially severe consequences. Thus, it is important to identify the maximum scour depth to ensure that the designed buried depth is adequate. There are a range of methods that may be applied to this problem, including the fluvial process analysis method, geological structure analysis method, scour formula method, scour model experiment method, and numerical simulation method. However, the applic...

  12. A Case Study on Stratified Settlement and Rebound Characteristics due to Dewatering in Shanghai Subway Station

    OpenAIRE

    Wang, Jianxiu; Huang, Tianrong; Sui, Dongchang

    2013-01-01

    Based on the Yishan Metro Station Project of Shanghai Metro Line number 9, a centrifugal model test was conducted to investigate the behavior of stratified settlement and rebound (SSR) of Shanghai soft clay caused by dewatering in deep subway station pit. The soil model was composed of three layers, and the dewatering process was simulated by self-invention of decompressing devise. The results indicate that SSR occurs when the decompression was carried out, and only negative rebound was found...

  13. a New Approach for Subway Tunnel Deformation Monitoring: High-Resolution Terrestrial Laser Scanning

    Science.gov (United States)

    Li, J.; Wan, Y.; Gao, X.

    2012-07-01

    With the improvement of the accuracy and efficiency of laser scanning technology, high-resolution terrestrial laser scanning (TLS) technology can obtain high precise points-cloud and density distribution and can be applied to high-precision deformation monitoring of subway tunnels and high-speed railway bridges and other fields. In this paper, a new approach using a points-cloud segmentation method based on vectors of neighbor points and surface fitting method based on moving least squares was proposed and applied to subway tunnel deformation monitoring in Tianjin combined with a new high-resolution terrestrial laser scanner (Riegl VZ-400). There were three main procedures. Firstly, a points-cloud consisted of several scanning was registered by linearized iterative least squares approach to improve the accuracy of registration, and several control points were acquired by total stations (TS) and then adjusted. Secondly, the registered points-cloud was resampled and segmented based on vectors of neighbor points to select suitable points. Thirdly, the selected points were used to fit the subway tunnel surface with moving least squares algorithm. Then a series of parallel sections obtained from temporal series of fitting tunnel surfaces were compared to analysis the deformation. Finally, the results of the approach in z direction were compared with the fiber optical displacement sensor approach and the results in x, y directions were compared with TS respectively, and comparison results showed the accuracy errors of x, y, z directions were respectively about 1.5 mm, 2 mm, 1 mm. Therefore the new approach using high-resolution TLS can meet the demand of subway tunnel deformation monitoring.

  14. A NEW APPROACH FOR SUBWAY TUNNEL DEFORMATION MONITORING: HIGH-RESOLUTION TERRESTRIAL LASER SCANNING

    Directory of Open Access Journals (Sweden)

    J. Li

    2012-07-01

    Full Text Available With the improvement of the accuracy and efficiency of laser scanning technology, high-resolution terrestrial laser scanning (TLS technology can obtain high precise points-cloud and density distribution and can be applied to high-precision deformation monitoring of subway tunnels and high-speed railway bridges and other fields. In this paper, a new approach using a points-cloud segmentation method based on vectors of neighbor points and surface fitting method based on moving least squares was proposed and applied to subway tunnel deformation monitoring in Tianjin combined with a new high-resolution terrestrial laser scanner (Riegl VZ-400. There were three main procedures. Firstly, a points-cloud consisted of several scanning was registered by linearized iterative least squares approach to improve the accuracy of registration, and several control points were acquired by total stations (TS and then adjusted. Secondly, the registered points-cloud was resampled and segmented based on vectors of neighbor points to select suitable points. Thirdly, the selected points were used to fit the subway tunnel surface with moving least squares algorithm. Then a series of parallel sections obtained from temporal series of fitting tunnel surfaces were compared to analysis the deformation. Finally, the results of the approach in z direction were compared with the fiber optical displacement sensor approach and the results in x, y directions were compared with TS respectively, and comparison results showed the accuracy errors of x, y, z directions were respectively about 1.5 mm, 2 mm, 1 mm. Therefore the new approach using high-resolution TLS can meet the demand of subway tunnel deformation monitoring.

  15. Marketingová strategie franchisingového řetězce Subway

    OpenAIRE

    Vostrý, Filip

    2011-01-01

    The aim of this work is to theoretically describe the functioning of marketing and franchising in all its aspects and with each other. On the particular example of SUBWAY chain I discovered weaknesses in terms of marketing and then tried to eliminate them and to propose some helpful changes. Practical part is based both on personal knowledge and information from owners and managers of several restaurants in Prague and Brno.

  16. Hydrochemistry of urban groundwater, Seoul, Korea: the impact of subway tunnels on groundwater quality.

    Science.gov (United States)

    Chae, Gi-Tak; Yun, Seong-Taek; Choi, Byoung-Young; Yu, Soon-Young; Jo, Ho-Young; Mayer, Bernhard; Kim, Yun-Jong; Lee, Jin-Yong

    2008-10-23

    Hydrogeologic and hydrochemical data for subway tunnel seepage waters in Seoul (Republic of Korea) were examined to understand the effect of underground tunnels on the degradation of urban groundwater. A very large quantity of groundwater (up to 63 million m3 year(-1)) is discharged into subway tunnels with a total length of 287 km, resulting in a significant drop of the local groundwater table and the abandonment of groundwater wells. For the tunnel seepage water samples (n = 72) collected from 43 subway stations, at least one parameter among pathogenic microbes (total coliform, heterotrophic bacteria), dissolved Mn and Fe, NH4+, NO3(-), turbidity, and color exceeded the Korean Drinking Water Standards. Locally, tunnel seepage water was enriched in dissolved Mn (avg. 0.70 mg L(-1), max. 5.58 mg L(-1)), in addition to dissolved Fe, NH4+, and pathogenic microbes, likely due to significant inflow of sewage water from broken or leaking sewer pipes. Geochemical modeling of redox reactions was conducted to simulate the characteristic hydrochemistry of subway tunnel seepage. The results show that variations in the reducing conditions occur in urban groundwater, dependent upon the amount of organic matter-rich municipal sewage contaminating the aquifer. The organic matter facilitates the reduction and dissolution of Mn- and Fe-bearing solids in aquifers and/or tunnel construction materials, resulting in the successive increase of dissolved Mn and Fe. The present study clearly demonstrates that locally significant deterioration of urban groundwater is caused by a series of interlinked hydrogeologic and hydrochemical changes induced by underground tunnels.

  17. A risk-based method for planning of bus–subway corridor evacuation under hybrid uncertainties

    International Nuclear Information System (INIS)

    Lv, Y.; Yan, X.D.; Sun, W.; Gao, Z.Y.

    2015-01-01

    Emergencies involved in a bus–subway corridor system are associated with many processes and factors with social and economic implications. These processes and factors and their interactions are related to a variety of uncertainties. In this study, an interval chance-constrained integer programming (EICI) method is developed in response to such challenges for bus–subway corridor based evacuation planning. The method couples a chance-constrained programming with an interval integer programming model framework. It can thus deal with interval uncertainties that cannot be quantified with specified probability distribution functions. Meanwhile, it can also reflect stochastic features of traffic flow capacity, and thereby help examine the related violation risk of constraint. The EICI method is applied to a subway incident based evacuation case study. It is solved through an interactive algorithm that does not lead to more complicated intermediate submodels and has a relatively low computational requirement. A number of decision alternatives could be directly generated based on results from the EICI method. It is indicated that the solutions cannot only help decision makers identify desired population evacuation and vehicle dispatch schemes under hybrid uncertainties, but also provide bases for in-depth analyses of tradeoffs among evacuation plans, total evacuation time, and constraint-violation risks. - Highlights: • An inexact model is developed for the bus–subway corridor evacuation management. • It tackles stochastic and interval uncertainties in an integer programming problem. • It can examine violation risk of the roadway flow capacity related constraint. • It will help identify evacuation schemes under hybrid uncertainties

  18. A new look at inhalable metalliferous airborne particles on rail subway platforms.

    Science.gov (United States)

    Moreno, Teresa; Martins, Vânia; Querol, Xavier; Jones, Tim; BéruBé, Kelly; Minguillón, Maria Cruz; Amato, Fulvio; Capdevila, Marta; de Miguel, Eladio; Centelles, Sonia; Gibbons, Wes

    2015-02-01

    Most particles breathed on rail subway platforms are highly ferruginous (FePM) and extremely small (nanometric to a few microns in size). High magnification observations of particle texture and chemistry on airborne PM₁₀ samples collected from the Barcelona Metro, combined with published experimental work on particle generation by frictional sliding, allow us to propose a general model to explain the origin of most subway FePM. Particle generation occurs by mechanical wear at the brake-wheel and wheel-rail interfaces, where magnetic metallic flakes and splinters are released and undergo progressive atmospheric oxidation from metallic iron to magnetite and maghemite. Flakes of magnetite typically comprise mottled mosaics of octahedral nanocrystals (10-20 nm) that become pseudomorphed by maghemite. Continued oxidation results in extensive alteration of the magnetic nanostructure to more rounded aggregates of non-magnetic hematite nanocrystals, with magnetic precursors (including iron metal) still preserved in some particle cores. Particles derived from steel wheel and rails contain a characteristic trace element chemistry, typically with Mn/Fe=0.01. Flakes released from brakes are chemically very distinctive, depending on the pad composition, being always carbonaceous, commonly barium-rich, and texturally inhomogeneous, with trace elements present in nanominerals incorporated within the crystalline structure. In the studied subway lines of Barcelona at least there appears to be only a minimal aerosol contribution from high temperature processes such as sparking. To date there is no strong evidence that these chemically and texturally complex inhalable metallic materials are any more or less toxic than street-level urban particles, and as with outdoor air, the priority in subway air quality should be to reduce high mass concentrations of aerosol present in some stations. Copyright © 2014. Published by Elsevier B.V.

  19. Estimation of inhaled airborne particle number concentration by subway users in Seoul, Korea.

    Science.gov (United States)

    Kim, Minhae; Park, Sechan; Namgung, Hyeong-Gyu; Kwon, Soon-Bark

    2017-12-01

    Exposure to airborne particulate matter (PM) causes several diseases in the human body. The smaller particles, which have relatively large surface areas, are actually more harmful to the human body since they can penetrate deeper parts of the lungs or become secondary pollutants by bonding with other atmospheric pollutants, such as nitrogen oxides. The purpose of this study is to present the number of PM inhaled by subway users as a possible reference material for any analysis of the hazards to the human body arising from the inhalation of such PM. Two transfer stations in Seoul, Korea, which have the greatest number of users, were selected for this study. For 0.3-0.422 μm PM, particle number concentration (PNC) was highest outdoors but decreased as the tester moved deeper underground. On the other hand, the PNC between 1 and 10 μm increased as the tester moved deeper underground and showed a high number concentration inside the subway train as well. An analysis of the particles to which subway users are actually exposed to (inhaled particle number), using particle concentration at each measurement location, the average inhalation rate of an adult, and the average stay time at each location, all showed that particles sized 0.01-0.422 μm are mostly inhaled from the outdoor air whereas particles sized 1-10 μm are inhaled as the passengers move deeper underground. Based on these findings, we expect that the inhaled particle number of subway users can be used as reference data for an evaluation of the hazards to health caused by PM inhalation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Transient variation of aerosol size distribution in an underground subway station.

    Science.gov (United States)

    Kwon, Soon-Bark; Namgung, Hyeong-Gyu; Jeong, Wootae; Park, Duckshin; Eom, Jin Ki

    2016-06-01

    As the number of people using rapid transit systems (subways) continues to rise in major cities worldwide, increasing attention has been given to the indoor air quality of underground stations. This study intended to observe the change of PM distribution by size in an underground station with PSDs installed located near the main road in downtown Seoul, as well as to examine causes for the changes. The results indicate that the PM suspended in the tunnel flowed into the platform area even in a subway station where the effect of train-induced wind is blocked by installed PSDs, as this flow occurred when the PSDs were opened. The results also indicate that coarse mode particles generated by mechanical friction in the tunnel, such as that between wheels and rail, also flowed into the platform area. The PM either settled or was re-suspended according to size and whether the ventilation in the platform area was in operation or if the platform floor had been washed. The ventilation system was more effective in removing PM of smaller sizes (fine particles) while the wash-out performed after train operations had stopped reduced the suspension of coarse mode particles the next morning. Despite installation of the completely sealed PSDs, inflow of coarse mode particles from the tunnel seems unavoidable, indicating the need for measures to decrease the PM generated there to lower subway user exposure since those particles cannot be reduced by mechanical ventilation alone. This research implicate that coarse PM containing heavy metals (generated from tunnel side) proliferated especially during rush hours, during which it is very important to control those PM in order to reduce subway user exposure to this hazardous PM.

  1. Major depressive disorder, panic disorder, and post-traumatic stress disorder in Korean subway drivers.

    Science.gov (United States)

    Kim, Hyoung-Ryoul; Yim, Hyeon Woo; Jo, Sun-Jin; Choi, Bongkyoo; Jeong, Seung Hee; Lee, Kang Sook; Park, Jong-Ik; Chang, Sung Man

    2013-05-01

    The purposes of this study are to investigate the prevalence of major depressive disorder, panic disorder, and post-traumatic stress disorder (PTSD) in Korean subway drivers, and find the association between these disorders and the drivers' person-under-train (PUT) experiences. A total of 826 subway drivers who participated in a cross-sectional work and health survey were included for this study. The Korean version of the Composite International Diagnostic Interview 2.1 was applied to assess major depressive disorder, panic disorder, and PTSD. The date of PUT, whether victim died, and how many PUTs the drivers experienced were asked using a structured questionnaire. The standardized prevalence ratios (SPRs) for lifetime prevalence of panic disorder and PTSD in subway drivers were 13.3 (95 % confidence interval [CI] 6.6-22.4) and 2.1 (95 % CI 1.1-3.4), respectively. In lifetime prevalence, after adjusting for age, education, income, and working career, the drivers who experienced PUT had significantly higher risks for panic disorder (odds ratio [OR] = 4.2, 95 % CI 1.2-16.6) and PTSD (OR = 4.4, 95 % CI 1.3-16.4). In 1-year prevalence, the drivers who experienced PUT had a significantly higher risk for PTSD (OR = 11.7, 95 % CI 1.9-225.8). There was no significant value of SPR and OR in major depressive disorder. This study suggests that Korean subway drivers are at higher risk for panic disorder and PTSD compared to the general population, and PUT experience is associated with panic disorder and PTSD. Drivers who have experienced PUT should be treated quickly, sympathetically, and sensitively by a psychological professional and their colleagues, so they can return to work soon.

  2. Research on the Effects of Heterogeneity on Pedestrian Dynamics in Walkway of Subway Station

    Directory of Open Access Journals (Sweden)

    Haoling Wu

    2016-01-01

    Full Text Available The major objective of this paper is to study the effects of heterogeneity on pedestrian dynamics in walkway of subway station. We analyze the observed data of the selected facility and find that walking speed and occupied space were varied in the population. In reality, pedestrians are heterogeneous individuals with different attributes. However, the research on how the heterogeneity affects the pedestrian dynamics in facilities of subway stations is insufficient. The improved floor field model is therefore presented to explore the effects of heterogeneity. Pedestrians are classified into pedestrians walking in pairs, fast pedestrians, and ordinary pedestrians. For convenience, they are denoted as P-pedestrians, F-pedestrians, and O-pedestrians, respectively. The proposed model is validated under homogeneous and heterogeneous conditions. Three pedestrian compositions are simulated to analyze the effects of heterogeneity on pedestrian dynamics. The results show that P-pedestrians have negative effect and F-pedestrians have positive effect. All of the results in this paper indicate that the capacity of walkway is not a constant value. It changes with different component proportions of heterogeneous pedestrians. The heterogeneity of pedestrian has an important influence on the pedestrian dynamics in the walkway of the subway station.

  3. Experimental Study on the Vibration Control Effect of Long Elastic Sleeper Track in Subways

    Directory of Open Access Journals (Sweden)

    Xiaopei Cai

    2018-01-01

    Full Text Available The vibration effect of urban rail transit has gained attention from both academia and the industry sector. Long Elastic Sleeper Track (LEST is a new structure for vibration reduction which has recently been designed and applied to Chinese subways. However, little research has been devoted to its vibration reduction effect. In this study, field tests were conducted during peak transit hours on Beijing Subway Line 15 to examine the vibration reduction effects of the common ballastless track and LEST on both straight and curved sections. The results demonstrate that although LEST increases the wheel-rail vertical forces, rail vertical displacements, and rail accelerations to some extent, these effects do not threaten subway operational safety, and vibrations of track bed and tunnel wall are positively mitigated. LEST has an obvious vibration reduction effect at frequencies above 40 Hz. In straight track, the vibration of bottom of the tunnel wall measured in one-third octave bands is reduced by 10.52 dB, while the vibration at point on the tunnel wall at 1.5 m height is reduced by 9.60 dB. For the curved track, the vibrations at those two points are reduced by 9.35 dB and 8.44 dB, respectively. This indicates that LEST reduces vibrations slightly more for the straight track than for the curved track.

  4. Evaluation of the air quality benefits of the subway system in São Paulo, Brazil.

    Science.gov (United States)

    Silva, Cacilda Bastos Pereira da; Saldiva, Paulo Hilário Nascimento; Amato-Lourenço, Luis Fernando; Rodrigues-Silva, Fernando; Miraglia, Simone Georges El Khouri

    2012-06-30

    Air pollution is a severe problem in major urban areas due to increasing numbers of vehicles, reduced road capacity and few investments in public transportation, especially in developing countries. Public transportation has a special role in avoiding congestion and consequent environmental and health impacts but is considered expensive. The objective of this paper was to analyze the benefits of the São Paulo subway in terms of the air pollution in the city through strikes events, analyzing both the health outcomes and the related economic burden. For the strike events, increases in air pollutant concentrations during the strike day was observed when compared to a similar day in terms of day of the week and meteorological conditions. Increases in mortality were also observed and the associated economic burden calculated. Despite the elevated construction and operation costs of the subway, when environment and social values are considered, cost-benefit analysis results would indicate a worthwhile investment. The consideration of these aspects is essential to sustainable transportation analyses, and in the case of the São Paulo subway, our analysis clearly demonstrated the important role of this system in the city's environmental, social and economic attributes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Aerosols released in accidents in reprocessing plants

    International Nuclear Information System (INIS)

    Ballinger, M.Y.; Owczarski, P.C.; Hashimoto, K.; Nishio, G.; Jordan, S.; Lindner, W.

    1987-01-01

    For analyzing the thermodynamic and radiological consequences of solvent fire accidents in reprocessing plants, intensive investigations on burning contaminated condensible liquids were performed at Kernforschungszentrum Karlsruhe (KfK), Pacific Northwest Laboratory (PNL), and Japan Atomic Energy Research Institute (JAERI). In small- and large-scale tests, KfK studied the behavior of kerosene, tributyl phosphate, HNO 3 mixture fires in open air and closed containments. The particle release from uranium-contaminated pool fires was investigated. Different filter devices were tested. For analyzing fires, PNL has developed the FIRIN computer code and has generated small-scale fire data in support of that code. The results of the experiments in which contaminated combustible liquids were burned demonstrate the use of the FIRIN code in simulating a solvent fire in a nuclear reprocessing plant. To demonstrate the safety evaluation of a postulated solvent fire in an extraction process of a reprocessing pant, JAERI conducted large-scale fire tests. Behavior of solvent fires in a cell and the integrity of high-efficiency particulate air (HEPA) filters due to smoke plugging were investigated. To evaluate confinement of radioactive materials released from the solvent fire, the ventilation systems with HEPA filters were tested under postulated fire conditions

  6. Criticality accident:

    International Nuclear Information System (INIS)

    Canavese, Susana I.

    2000-01-01

    A criticality accident occurred at 10:35 on September 30, 1999. It occurred in a precipitation tank in a Conversion Test Building at the JCO Tokai Works site in Tokaimura (Tokai Village) in the Ibaraki Prefecture of Japan. STA provisionally rated this accident a 4 on the seven-level, logarithmic International Nuclear Event Scale (INES). The September 30, 1999 criticality accident at the JCO Tokai Works Site in Tokaimura, Japan in described in preliminary, technical detail. Information is based on preliminary presentations to technical groups by Japanese scientists and spokespersons, translations by technical and non-technical persons of technical web postings by various nuclear authorities, and English-language non-technical reports from various news media and nuclear-interest groups. (author)

  7. Fire and explosion security in the petroleum sector

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    The conference has 12 presentations on topics regarding fire fighting, explosions and development scenarios, safety and security aspects, management of safety issues and measures and preparedness. Some accidents and fires are discussed. Some important problems with LNG with respects to plants, transport, fires and risk assessment are presented.

  8. Identification of the sources of PM10 in a subway tunnel using positive matrix factorization.

    Science.gov (United States)

    Park, Duckshin; Lee, Taejeong; Hwang, Doyeon; Jung, Wonseok; Lee, Yongil; Cho, KiChul; Kim, Dongsool; Lees, Kiyoung

    2014-12-01

    The level of particulate matter of less than 10 μm diameter (PM10) at subway platforms can be significantly reduced by installing a platform screen-door system. However, both workers and passengers might be exposed to higher PM10 levels while the cars are within the tunnel because it is a more confined environment. This study determined the PM10 levels in a subway tunnel, and identified the sources of PM10 using elemental analysis and receptor modeling. Forty-four PM10 samples were collected in the tunnel between the Gireum and Mia stations on Line 4 in metropolitan Seoul and analyzed using inductively coupled plasma-atomic emission spectrometry and ion chromatography. The major PM10 sources were identified using positive matrix factorization (PMF). The average PM10 concentration in the tunnels was 200.8 ± 22.0 μg/m3. Elemental analysis indicated that the PM10 consisted of 40.4% inorganic species, 9.1% anions, 4.9% cations, and 45.6% other materials. Iron was the most abundant element, with an average concentration of 72.5 ± 10.4 μg/m3. The PM10 sources characterized by PMF included rail, wheel, and brake wear (59.6%), soil combustion (17.0%), secondary aerosols (10.0%), electric cable wear (8.1%), and soil and road dust (5.4%). Internal sources comprising rail, wheel, brake, and electric cable wear made the greatest contribution to the PM10 (67.7%) in tunnel air. Implications: With installation of a platform screen door, PM10 levels in subway tunnels were higher than those on platforms. Tunnel PM10 levels exceeded 150 µg/m3 of the Korean standard for subway platform. Elemental analysis of PM10 in a tunnel showed that Fe was the most abundant element. Five PM10 sources in tunnel were identified by positive matrix factorization. Railroad-related sources contributed 68% of PM10 in the subway tunnel.

  9. Vulnerability of bridges to fire

    DEFF Research Database (Denmark)

    Giuliani, Luisa; Crosti, C.; Gentili, F.

    2012-01-01

    Even if recent effort in developing methodology and measures for design structures against fire and explosions has been mostly focused on buildings, bridges can also be very sensitive to those actions, as witnesses by some recent bridge accidents, which caused major economic losses and also endan...

  10. Humans and Machines in the subway Humanos e máquinas no metrô

    Directory of Open Access Journals (Sweden)

    Janice Caiafa

    2011-07-01

    Full Text Available In this work we analyze the repercussions that the recent implementation of an electronic fare collection system - with smart cards – has brought to everyday life of subway riders in Rio de Janeiro. The adoption of a fare collection system involves the choice of a technology and the stipulation of a charging system. By following this technological evolution in Rio de Janeiro’s subway, we explore how its riders learn to approach the new interfaces with the automatic machines and to cope with the payment conditions, which are at the same time imposed. We note, in this context, how the technological devices are coupled to human actions regarding the construction of a new fare collection system as well as the sociability that is developed in the subway technological space.Resumo: Neste trabalho analisamos as repercussões que a recente implementação de um novo sistema de bilhetagem eletrônica trouxe para o quotidiano dos usuários do metrô do Rio de Janeiro. A adoção de um sistema de bilhetagem envolve a escolha de uma tecnologia e a estipulação de um regime de cobrança. Ao acompanhar essa evolução tecnológia no metrô do Rio de Janeiro, exploramos como os usuários têm aprendido a abordar as novas interfaces com as máquinas automáticas e enfrentado as condições de pagamento que no mesmo golpe são impostas. Observamos como as ferramentas tecnológicas se acoplam a ações humanas tanto no que diz respeito à própria construção do novo sistema quanto à sociabilidade que se desenvolve no espaço tecnológico do metrô. Palavras-Chave: Tecnologia; Metrô (Rio de Janeiro; Sociabilidade Abstract: In this work we analyze the repercussions of the recently implemented fare collection system with smart cards in the Rio de Janeiro subway. The implementation of a fare collection system involves opting for a certain technology as well as stipulating a regime of fare charging. As we follow this technological evolution in the Rio

  11. Chemical speciation of size-segregated floor dusts and airborne magnetic particles collected at underground subway stations in Seoul, Korea

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hae-Jin; Kim, BoWha; Malek, Md Abdul [Department of Chemistry, Inha University, 253, Yonghyun-dong, Nam-gu, Incheon 402-751 (Korea, Republic of); Koo, Yong Sung; Jung, Jong Hoon [Department of Physics, Inha University, 253, Yonghyun-dong, Nam-gu, Incheon 402-751 (Korea, Republic of); Son, Youn-Suk [Department of Advanced Technology Fusion, Konkuk University, Seoul 143-701 (Korea, Republic of); Kim, Jo-Chun [Department of Advanced Technology Fusion, Konkuk University, Seoul 143-701 (Korea, Republic of); Department of Environmental Engineering, Konkuk University, Seoul 143-701 (Korea, Republic of); Kim, HyeKyoung [Department of Chemistry, Inha University, 253, Yonghyun-dong, Nam-gu, Incheon 402-751 (Korea, Republic of); Ro, Chul-Un, E-mail: curo@inha.ac.kr [Department of Chemistry, Inha University, 253, Yonghyun-dong, Nam-gu, Incheon 402-751 (Korea, Republic of)

    2012-04-30

    Highlights: Black-Right-Pointing-Pointer We examined chemical species of floor dusts and airborne magnetic subway particles collected at underground subway stations. Black-Right-Pointing-Pointer XRD, SEM/EDX, and VSM measurements provided information on their major iron species, which is relatively harmless iron metal. Black-Right-Pointing-Pointer PM levels at underground subway stations can be controlled by removing magnetic indoor particles using magnets. - Abstract: Previous studies have reported the major chemical species of underground subway particles to be Fe-containing species that are generated from wear and friction processes at rail-wheel-brake and catenaries-pantographs interfaces. To examine chemical composition of Fe-containing particles in more details, floor dusts were collected at five sampling locations of an underground subway station. Size-segregated floor dusts were separated into magnetic and non-magnetic fractions using a permanent magnet. Using X-ray diffraction (XRD) and scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDX), iron metal, which is relatively harmless, was found to be the dominating chemical species in the floor dusts of the <25 {mu}m size fractions with minor fractions of Mg, Al, Si, Ca, S, and C. From SEM analysis, the floor dusts of the <25 {mu}m size fractions collected on railroad ties appeared to be smaller than 10 {mu}m, indicating that their characteristics should somewhat reflect the characteristics of airborne particles in the tunnel and the platform. As most floor dusts are magnetic, PM levels at underground subway stations can be controlled by removing magnetic indoor particles using magnets. In addition, airborne subway particles, most of which were smaller than 10 {mu}m, were collected using permanent magnets at two underground subway stations, namely Jegi and Yangjae stations, in Seoul, Korea. XRD and SEM/EDX analyses showed that most of the magnetic aerosol particles collected at Jegi

  12. Chemical speciation of size-segregated floor dusts and airborne magnetic particles collected at underground subway stations in Seoul, Korea

    International Nuclear Information System (INIS)

    Jung, Hae-Jin; Kim, BoWha; Malek, Md Abdul; Koo, Yong Sung; Jung, Jong Hoon; Son, Youn-Suk; Kim, Jo-Chun; Kim, HyeKyoung; Ro, Chul-Un

    2012-01-01

    Highlights: ► We examined chemical species of floor dusts and airborne magnetic subway particles collected at underground subway stations. ► XRD, SEM/EDX, and VSM measurements provided information on their major iron species, which is relatively harmless iron metal. ► PM levels at underground subway stations can be controlled by removing magnetic indoor particles using magnets. - Abstract: Previous studies have reported the major chemical species of underground subway particles to be Fe-containing species that are generated from wear and friction processes at rail–wheel–brake and catenaries–pantographs interfaces. To examine chemical composition of Fe-containing particles in more details, floor dusts were collected at five sampling locations of an underground subway station. Size-segregated floor dusts were separated into magnetic and non-magnetic fractions using a permanent magnet. Using X-ray diffraction (XRD) and scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDX), iron metal, which is relatively harmless, was found to be the dominating chemical species in the floor dusts of the <25 μm size fractions with minor fractions of Mg, Al, Si, Ca, S, and C. From SEM analysis, the floor dusts of the <25 μm size fractions collected on railroad ties appeared to be smaller than 10 μm, indicating that their characteristics should somewhat reflect the characteristics of airborne particles in the tunnel and the platform. As most floor dusts are magnetic, PM levels at underground subway stations can be controlled by removing magnetic indoor particles using magnets. In addition, airborne subway particles, most of which were smaller than 10 μm, were collected using permanent magnets at two underground subway stations, namely Jegi and Yangjae stations, in Seoul, Korea. XRD and SEM/EDX analyses showed that most of the magnetic aerosol particles collected at Jegi station was iron metal, whereas those at Yangjae station contained a small amount

  13. Polycyclic aromatic hydrocarbons (PAH) and diesel engine emission (elemental carbon) inside a car and a subway train.

    Science.gov (United States)

    Fromme, H; Oddoy, A; Piloty, M; Krause, M; Lahrz, T

    1998-06-30

    Significant concentrations of potentially harmful substances can be present in the interior of vehicles. The main sources of PAHs and elemental carbon (EC) inside a car are likely to be combustion emissions, especially from coal and traffic. The same sources can also be important for the interior of a subway train for which there are specific sources in the tunnel system, for example diesel engines. Twice, in summer 1995 and winter 1996 polycyclic aromatic hydrocarbons (PAH) and diesel motor emission (estimated as elemental carbon) were determined in the interior of a car (a 2-year-old VW Golf with a three-way catalytic converter) and in the passenger compartment of a subway train (below ground). On each sampling day (in total 16 daily measurements in the car and 16 in the subway) the substances were determined in the breathing zone of the passengers from 07:00 h to 16:00 h under different meteorologic conditions (winter- and summertime). The car followed the route of the subway from the western Berlin borough of Spandau to the south-eastern borough of Neukölln, and back. The sampling represented a realistic exposure model for driving in a high traffic and polluted urban area. The electric subway train (also 2 years in use) connected the same parts of Berlin (31 km underground). The mean values obtained during the two measurement periods (summer/winter) inside the car were 1.0 and 3.2 ng/m3 for benzo[a]pyrene, 10.2 and 28.7 ng/m3 for total-measured-PAHs, 14.1 and 8.2 micrograms/m3 for EC and in the subway 0.7 and 4.0 ng/m3 for benzol[a]pyrene, 30.2 and 67.5 ng/m3 for total PAHs, 109 and 6.9 micrograms/m3 for EC. A comparison between subway and car exposures shows significantly higher concentrations of PAHs in the subway train, which can be explained by relatively high concentrations of fluoranthene and pyrene in the subway. So far a satisfactory explanation has not been found, but one source might be the wooden railway ties which were formerly preserved with tar

  14. Monitoring Ground Deformation of Subway Area during the Construction Based on the Method of Multi-Temporal Coherent Targets Analysis

    Science.gov (United States)

    Zhang, L.; Wu, J.; Zhao, J.; Yuan, M.

    2018-04-01

    Multi-temporal coherent targets analysis is a high-precision and high-spatial-resolution monitoring method for urban surface deformation based on Differential Synthetic Aperture Radar (DInSAR), and has been successfully applied to measure land subsidence, landslide and strain accumulation caused by fault movement and so on. In this paper, the multi-temporal coherent targets analysis is used to study the settlement of subway area during the period of subway construction. The eastern extension of Shanghai Metro Line. 2 is taking as an example to study the subway settlement during the construction period. The eastern extension of Shanghai Metro Line. 2 starts from Longyang Road and ends at Pudong airport. Its length is 29.9 kilometers from east to west and it is a key transportation line to the Pudong Airport. 17 PalSAR images during 2007 and 2010 are applied to analyze and invert the settlement of the buildings nearby the subway based on the multi-temporal coherent targets analysis. But there are three significant deformation areas nearby the Line 2 between 2007 and 2010, with maximum subsidence rate up to 30 mm/y in LOS. The settlement near the Longyang Road station and Chuansha Town are both caused by newly construction and city expansion. The deformation of the coastal dikes suffer from heavy settlement and the rate is up to -30 mm/y. In general, the area close to the subway line is relatively stable during the construction period.

  15. Embedding human annoyance rate models in wireless smart sensors for assessing the influence of subway train-induced ambient vibration

    Science.gov (United States)

    Sun, Ke; Zhang, Wei; Ding, Huaping; Kim, Robin E.; Spencer, Billie F., Jr.

    2016-10-01

    The operation of subway trains induces ambient vibrations, which may cause annoyance and other adverse effects on humans, eventually leading to physical, physiological, and psychological problems. In this paper, the human annoyance rate (HAR) models, used to assess the human comfort under the subway train-induced ambient vibrations, were deduced and the calibration curves for 5 typical use circumstances were addressed. An autonomous measurement system, based on the Imote2, wireless smart sensor (WSS) platform, plus the SHM-H, high-sensitivity accelerometer board, was developed for the HAR assessment. The calibration curves were digitized and embedded in the computational core of the WSS unit. Experimental validation was conducted, using the developed system on a large underground reinforced concrete frame structure adjoining the subway station. The ambient acceleration of both basement floors was measured; the embedded computation was implemented and the HAR assessment results were wirelessly transmitted to the central server, all by the WSS unit. The HAR distributions of the testing areas were identified, and the extent to which both basements will be influenced by the close-up subway-train’s operation, in term of the 5 typical use circumstances, were quantitatively assessed. The potential of the WSS-based autonomous system for the fast environment impact assessment of the subway train-induced ambient vibration was well demonstrated.

  16. Characterisation of nano- and micron-sized airborne and collected subway particles, a multi-analytical approach.

    Science.gov (United States)

    Midander, Klara; Elihn, Karine; Wallén, Anna; Belova, Lyuba; Karlsson, Anna-Karin Borg; Wallinder, Inger Odnevall

    2012-06-15

    Continuous daily measurements of airborne particles were conducted during specific periods at an underground platform within the subway system of the city center of Stockholm, Sweden. Main emphasis was placed on number concentration, particle size distribution, soot content (analyzed as elemental and black carbon) and surface area concentration. Conventional measurements of mass concentrations were conducted in parallel as well as analysis of particle morphology, bulk- and surface composition. In addition, the presence of volatile and semi volatile organic compounds within freshly collected particle fractions of PM(10) and PM(2.5) were investigated and grouped according to functional groups. Similar periodic measurements were conducted at street level for comparison. The investigation clearly demonstrates a large dominance in number concentration of airborne nano-sized particles compared to coarse particles in the subway. Out of a mean particle number concentration of 12000 particles/cm(3) (7500 to 20000 particles/cm(3)), only 190 particles/cm(3) were larger than 250 nm. Soot particles from diesel exhaust, and metal-containing particles, primarily iron, were observed in the subway aerosol. Unique measurements on freshly collected subway particle size fractions of PM(10) and PM(2.5) identified several volatile and semi-volatile organic compounds, the presence of carcinogenic aromatic compounds and traces of flame retardants. This interdisciplinary and multi-analytical investigation aims to provide an improved understanding of reported adverse health effects induced by subway aerosols. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Subway emergency preparedness in Shanghai: A focused group and interview study exploring the perceived experiences of senior citizens and the disabled.

    Science.gov (United States)

    Baffoe, Benjamin Ohene Kwapong; Shiyuan, Zheng

    As Shanghai's population increases and currently being boosted by an influx of foreigners, there has been pressure on the subway system and this has led to a great concern for the aged and disabled people (including foreigners) who use the subway during emergency situations. The present study uses an exploratory research approach including a focus group discussion (FGD) and interviews to uncover the experiences, safety concerns, and challenges that the aged and disabled faces when using the subway. A total of 38 participants were involved in the study, which comprises of three FGDs and interviews conducted in the city of Shanghai. The findings reveal that most aged and disabled subway riders have little or no knowledge about emergency safety measures or safety symbols, the administering of first aid and have language barrier concerns. This study recommends that policy makers and sub-way operators should get the aged and disabled people involved in developing more educational programs that will help them to better the concept of safety prevention measures and it also suggests holding more emergency drills involving the aged and disabled. Braille language symbols, sign languages on TV screens, specially designed sub-way maps, low-frequency alarms with flashing lights, and information printed in multiple international languages should also be provided to help foreigners understand the instructions and information in the subways. Additionally, these measures could help all commuters to feel safer when using the subway.

  18. Biomass accident investigations – missed opportunities for learning and accident prevention

    DEFF Research Database (Denmark)

    Hedlund, Frank Huess

    2017-01-01

    The past decade has seen a major increase in the production of energy from biomass. The growth has been mirrored in an increase of serious biomass related accidents involving fires, gas explosions, combustible dust explosions and the release of toxic gasses. There are indications that the number...... of bioenergy related accidents is growing faster than the energy production. This paper argues that biomass accidents, if properly investigated and lessons shared widely, provide ample opportunities for improving general hazard awareness and safety performance of the biomass industry. The paper examines...... selected serious accidents involving biogas and wood pellets in Denmark and argues that such opportunities for learning were missed because accident investigations were superficial, follow-up incomplete and information sharing absent. In one particularly distressing case, a facility saw a repeat accident...

  19. Airborne particulate metals in the New York City subway: A pilot study to assess the potential for health impacts✩,✩✩

    Science.gov (United States)

    Grass, David S.; Ross, James M.; Family, Farnosh; Barbour, Jonathan; Simpson, H. James; Coulibaly, Drissa; Hernandez, Jennifer; Chen, Yingdi; Slavkovich, Vesna; Li, Yongliang; Graziano, Joseph; Santella, Regina M.; Brandt-Rauf, Paul; Chillrud, Steven N.

    2011-01-01

    A prior study in New York City observed that airborne concentrations of three metals found in steel – iron, manganese, and chromium – are more than 100 times higher in the subway system than in aboveground air. To investigate the potential for health effects of exposure at these levels, we conducted a pilot study of subway workers comparing personal exposures to steel dust with biomarkers of metal exposure, oxidative stress, and DNA damage in blood and urine samples. Workers wore a personal air sampler operating at 4 L/m for one to three work shifts with blood and urine samples collected at the end of the final shift. We found that PM2.5 exposures varied among subway workers on the basis of job title and job activity. The subway workers’ mean time-weighted PM2.5 exposure was 52 µg/m3, with a median of 27 µg/m3, and a range of 6–469 µg/m3. The observed concentrations of PM2.5, iron, manganese, and chromium fell well below occupational standards. Biomarker concentrations among the 39 subway workers were compared with a group of 11 bus drivers, and a group of 25 suburban office workers. Concentrations of DNA–protein crosslinks and chromium in plasma were significantly higher in subway workers than in bus drivers, but no significant difference was observed for these biomarkers between subway workers and office workers. Urinary isoprostane concentrations were significantly correlated with the number of years working in the subway system, and were detected at higher, though not significantly higher, concentrations in subway workers than in bus drivers or office workers. At the group level, there was no consistent pattern of biomarker concentrations among subway workers significantly exceeding those of the bus drivers and office workers. At the individual level, steel dust exposure was not correlated with any of the biomarkers measured. PMID:19926083

  20. Accident selection methodology for TA-55 FSAR

    International Nuclear Information System (INIS)

    Letellier, B.C.; Pan, P.Y.; Sasser, M.K.

    1995-01-01

    In the past, the selection of representative accidents for refined analysis from the numerous scenarios identified in hazards analyses (HAs) has involved significant judgment and has been difficult to defend. As part of upgrading the Final Safety Analysis Report (FSAR) for the TA-55 plutonium facility at the Los Alamos National Laboratory, an accident selection process was developed that is mostly mechanical and reproducible in nature and fulfills the requirements of the Department of Energy (DOE) Standard 3009 and DOE Order 5480.23. Among the objectives specified by this guidance are the requirements that accident screening (1) consider accidents during normal and abnormal operating conditions, (2) consider both design basis and beyond design basis accidents, (3) characterize accidents by category (operational, natural phenomena, etc.) and by type (spill, explosion, fire, etc.), and (4) identify accidents that bound all foreseeable accident types. The accident selection process described here in the context of the TA-55 FSAR is applicable to all types of DOE facilities

  1. Accident knowledge and emergency management

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, B; Groenberg, C D

    1997-03-01

    The report contains an overall frame for transformation of knowledge and experience from risk analysis to emergency education. An accident model has been developed to describe the emergency situation. A key concept of this model is uncontrolled flow of energy (UFOE), essential elements are the state, location and movement of the energy (and mass). A UFOE can be considered as the driving force of an accident, e.g., an explosion, a fire, a release of heavy gases. As long as the energy is confined, i.e. the location and movement of the energy are under control, the situation is safe, but loss of confinement will create a hazardous situation that may develop into an accident. A domain model has been developed for representing accident and emergency scenarios occurring in society. The domain model uses three main categories: status, context and objectives. A domain is a group of activities with allied goals and elements and ten specific domains have been investigated: process plant, storage, nuclear power plant, energy distribution, marine transport of goods, marine transport of people, aviation, transport by road, transport by rail and natural disasters. Totally 25 accident cases were consulted and information was extracted for filling into the schematic representations with two to four cases pr. specific domain. (au) 41 tabs., 8 ills.; 79 refs.

  2. Accident knowledge and emergency management

    International Nuclear Information System (INIS)

    Rasmussen, B.; Groenberg, C.D.

    1997-03-01

    The report contains an overall frame for transformation of knowledge and experience from risk analysis to emergency education. An accident model has been developed to describe the emergency situation. A key concept of this model is uncontrolled flow of energy (UFOE), essential elements are the state, location and movement of the energy (and mass). A UFOE can be considered as the driving force of an accident, e.g., an explosion, a fire, a release of heavy gases. As long as the energy is confined, i.e. the location and movement of the energy are under control, the situation is safe, but loss of confinement will create a hazardous situation that may develop into an accident. A domain model has been developed for representing accident and emergency scenarios occurring in society. The domain model uses three main categories: status, context and objectives. A domain is a group of activities with allied goals and elements and ten specific domains have been investigated: process plant, storage, nuclear power plant, energy distribution, marine transport of goods, marine transport of people, aviation, transport by road, transport by rail and natural disasters. Totally 25 accident cases were consulted and information was extracted for filling into the schematic representations with two to four cases pr. specific domain. (au) 41 tabs., 8 ills.; 79 refs

  3. A statistical description of the types and severities of accidents involving tractor semi-trailers

    International Nuclear Information System (INIS)

    Clauss, D.B.; Wilson, R.K.; Blower, D.F.; Campbell, K.L.

    1994-06-01

    This report provides a statistical description of the types and severities of tractor semi-trailer accidents involving at least one fatality. The data were developed for use in risk assessments of hazardous materials transportation. Several accident databases were reviewed to determine their suitability to the task. The TIFA (Trucks Involved in Fatal Accidents) database created at the University of Michigan Transportation Research Institute was extensively utilized. Supplementary data on collision and fire severity, which was not available in the TIFA database, were obtained by reviewing police reports for selected TIFA accidents. The results are described in terms of frequencies of different accident types and cumulative distribution functions for the peak contact velocity, rollover skid distance, fire temperature, fire size, fire separation, and fire duration

  4. Tchernobyl accident

    International Nuclear Information System (INIS)

    1986-06-01

    First, R.M.B.K type reactors are described. Then, safety problems are dealt with reactor control, behavior during transients, normal loss of power and behavior of the reactor in case of leak. A possible scenario of the accident of Tchernobyl is proposed: events before the explosion, possible initiators, possible scenario and events subsequent to the core meltdown (corium-concrete interaction, interaction with the groundwater table). An estimation of the source term is proposed first from the installation characteristics and the supposed scenario of the accident, and from the measurements in Europe; radiological consequences are also estimated. Radioactivity measurements (Europe, Scandinavia, Western Europe, France) are given in tables (meteorological maps and fallouts in Europe). Finally, a description of the site is given [fr

  5. Accident: Reminder

    CERN Multimedia

    2003-01-01

    There is no left turn to Point 1 from the customs, direction CERN. A terrible accident happened last week on the Route de Meyrin just outside Entrance B because traffic regulations were not respected. You are reminded that when travelling from the customs, direction CERN, turning left to Point 1 is forbidden. Access to Point 1 from the customs is only via entering CERN, going down to the roundabout and coming back up to the traffic lights at Entrance B

  6. Manganese concentrations in the air of the Montreal (Canada) subway in relation to surface automobile traffic density

    Energy Technology Data Exchange (ETDEWEB)

    Boudia, Nacera; Gareau, Lise; Zayed, Joseph [GRIS Interdisciplinary Health Research Group, University of Montreal (Canada); Halley, Renee [Transport Montreal Society (Canada); Kennedy, Greg [Department of Engineering Physics, Ecole Polytechnique de Montreal, Montreal (Canada); Lambert, Jean [Department of Social and Preventive Medicine, Faculty of Medicine, University of Montreal (Canada)

    2006-07-31

    Methylcyclopentadienyl manganese tricarbonyl (MMT) is an organic derivative of manganese (Mn), used since 1976 in Canadian gasoline as an octane enhancer. Its combustion leads to the emission of Mn particles. Several studies carried out by our research group have established a correlation between atmospheric Mn concentrations and automobile traffic density, suggesting that MMT in gasoline could play a significant role. This study aims to measure Mn concentrations in the air of the underground subway in Montreal (Canada) and to examine the relation with nearby surface automobile traffic density and, by extension, with the use of MMT in gasoline. Three subway stations were chosen for their location in different microenvironments with different traffic densities. Respirable (MnR<5 {mu}m) and total Mn (MnT) were sampled over two weeks, 5 days/week, 12 h/day. For the station located in the lower traffic density area, relatively low levels of MnR and MnT were found, with averages of 0.018 and 0.032 {mu}g/m{sup 3}, respectively. These concentrations are within the range of the background levels in Montreal. For the other two stations, the average concentrations of MnR were twice as high and exceeded the US EPA reference concentration of 0.05 {mu}g/m{sup 3}. Although there may be several sources of Mn from different components of the subway structure and vehicles, no correlation was found between subway traffic and atmospheric Mn in the subway. Since the air in the underground subway is pumped directly from outside without filtration, our findings strongly suggest that the combustion of MMT in automobiles is an important factor. (author)

  7. Accident Prevention: A Workers' Education Manual.

    Science.gov (United States)

    International Labour Office, Geneva (Switzerland).

    Devoted to providing industrial workers with a greater knowledge of precautionary measures undertaken and enforced by industries for the protection of workers, this safety education manual contains 14 lessons ranging from "The Problems of Accidents during Work" to "Trade Unions and Workers and Industrial Safety." Fire protection, safety equipment…

  8. Experimental Benchmarking of Fire Modeling Simulations. Final Report

    International Nuclear Information System (INIS)

    Greiner, Miles; Lopez, Carlos

    2003-01-01

    A series of large-scale fire tests were performed at Sandia National Laboratories to simulate a nuclear waste transport package under severe accident conditions. The test data were used to benchmark and adjust the Container Analysis Fire Environment (CAFE) computer code. CAFE is a computational fluid dynamics fire model that accurately calculates the heat transfer from a large fire to a massive engulfed transport package. CAFE will be used in transport package design studies and risk analyses

  9. Fire Stations

    Data.gov (United States)

    Department of Homeland Security — Fire Stations in the United States Any location where fire fighters are stationed or based out of, or where equipment that such personnel use in carrying out their...

  10. Characterization of aerosol particles from Buenos Aires City and its subway system: PIXE and SEM/EDX

    International Nuclear Information System (INIS)

    Murruni, L. G.; Debray, M. E.; Minsky, D.; Kreiner, A. J.; Burlon, A.; Davidson, M.; Davidson, J.; Ozafran, M.; Vazquez, M. E.; Rosenbusch, M.; Ulke, A. G.; Solanes, V.

    2007-01-01

    This study analyzes total suspended particle (TSP) samples collected at two sites of Buenos Aires City (34S, 58W). One site (San Martin) placed 17 km from city center, and the other one at an underground subway station (Diagonal Norte) in downtown Buenos Aires. In both cases, gravimetric analysis has been performed, while elemental analysis using PIXE has been only carried out in the first case. To the best our knowledge, this is the first airborne particle measurement perform at a Buenos Aires underground subway station

  11. Multi-approach analysis of maximum riverbed scour depth above subway tunnel

    Directory of Open Access Journals (Sweden)

    Jun Chen

    2010-12-01

    Full Text Available When subway tunnels are routed underneath rivers, riverbed scour may expose the structure, with potentially severe consequences. Thus, it is important to identify the maximum scour depth to ensure that the designed buried depth is adequate. There are a range of methods that may be applied to this problem, including the fluvial process analysis method, geological structure analysis method, scour formula method, scour model experiment method, and numerical simulation method. However, the application ranges and forecasting precision of these methods vary considerably. In order to quantitatively analyze the characteristics of the different methods, a subway tunnel passing underneath a river was selected, and the aforementioned five methods were used to forecast the maximum scour depth. The fluvial process analysis method was used to characterize the river regime and evolution trend, which were the baseline for examination of the scour depth of the riverbed. The results obtained from the scour model experiment and the numerical simulation methods are reliable; these two methods are suitable for application to tunnel projects passing underneath rivers. The scour formula method was less accurate than the scour model experiment method; it is suitable for application to lower risk projects such as pipelines. The results of the geological structure analysis had low precision; the method is suitable for use as a secondary method to assist other research methods. To forecast the maximum scour depth of the riverbed above the subway tunnel, a combination of methods is suggested, and the appropriate analysis method should be chosen with respect to the local conditions.

  12. NON-TRIVIALITY OF THE RESULTS OF MILGRAM FIELD EXPERIMENT IN MOSCOW AND NEW YORK SUBWAY

    Directory of Open Access Journals (Sweden)

    Olga V Mitina

    2017-12-01

    Full Text Available Non-triviality of the results of the field experiment conducted on Stanley Milgram’s methodology in the New York and Moscow subway have been studied. The statistical significance of the difference between empirical and predicted results has been taken as the non-triviality criterion. 208 respondents (psychologists and students studying psychology were asked to predict an experimental result in dependence on an experimenter’s and subject’s gender, a subject’s age, and a city where the experiment was carried out. The obtained results have confirmed our hypothesis on non-triviality of the experiments in subways: it has been showed that there is a statistically significant difference between real behavior of subway passengers (in New York and in Moscow and predictions made by Moscow and Tashkent respondents. Practically in most cases the predicted probability that a subject gives a seat after request of experimenter (young woman or young man is much less than in reality. The structural equation modeling (SEM has been used to analyze the data by constructing the model taking account of all factors mentioned above. The model fit the experimental data well (CFI = 0.919. It has been found that predicted results depend not only on gender, age, and residence of a respondent but also on the degree of familiarity with the research. The obtained data give an important material for a further study of the role of situational (an experiment design and individual (respondent characteristics factors in predicted results; they contribute to further understanding of the problem of creation and support of non-formal social norms in various cultures and show new aspects of research carried out on experimental methodology of Stanley Milgram.

  13. CONTINUOUSLY DEFORMATION MONITORING OF SUBWAY TUNNEL BASED ON TERRESTRIAL POINT CLOUDS

    Directory of Open Access Journals (Sweden)

    Z. Kang

    2012-07-01

    Full Text Available The deformation monitoring of subway tunnel is of extraordinary necessity. Therefore, a method for deformation monitoring based on terrestrial point clouds is proposed in this paper. First, the traditional adjacent stations registration is replaced by sectioncontrolled registration, so that the common control points can be used by each station and thus the error accumulation avoided within a section. Afterwards, the central axis of the subway tunnel is determined through RANSAC (Random Sample Consensus algorithm and curve fitting. Although with very high resolution, laser points are still discrete and thus the vertical section is computed via the quadric fitting of the vicinity of interest, instead of the fitting of the whole model of a subway tunnel, which is determined by the intersection line rotated about the central axis of tunnel within a vertical plane. The extraction of the vertical section is then optimized using RANSAC for the purpose of filtering out noises. Based on the extracted vertical sections, the volume of tunnel deformation is estimated by the comparison between vertical sections extracted at the same position from different epochs of point clouds. Furthermore, the continuously extracted vertical sections are deployed to evaluate the convergent tendency of the tunnel. The proposed algorithms are verified using real datasets in terms of accuracy and computation efficiency. The experimental result of fitting accuracy analysis shows the maximum deviation between interpolated point and real point is 1.5 mm, and the minimum one is 0.1 mm; the convergent tendency of the tunnel was detected by the comparison of adjacent fitting radius. The maximum error is 6 mm, while the minimum one is 1 mm. The computation cost of vertical section abstraction is within 3 seconds/section, which proves high efficiency..

  14. Assessment of the noise annoyance among subway train conductors in Tehran, Iran.

    Science.gov (United States)

    Hamidi, Mansoureh; Kavousi, Amir; Zaheri, Somayeh; Hamadani, Abolfazl; Mirkazemi, Roksana

    2014-01-01

    Subway transportation system is a new phenomenon in Iran. Noise annoyance interferes with the individual's task performance, and the required alertness in the driving of subway trains. This is the first study conducted to measure the level of noise and noise annoyance among conductors of subway organization in Tehran, Iran. This cross sectional study was conducted among 167 randomly selected train conductors. Information related to noise annoyance was collected by using a self-administered questionnaire. The dosimetry and sound metering was done for the conductors and inside the cabins. There were 41 sound metering measuring samples inside the conductors' cabin, and there were 12 samples of conductors' noise exposure. The results of sound level meter showed that the mean Leq was 73.0 dBA ± 8.7 dBA and the dosimetry mean measured Leq was 82.1 dBA ± 6.8 dBA. 80% of conductors were very annoyed/annoyed by noise in their work place. 53.9% of conductors reported that noise affected their work performance and 63.5% reported that noise causes that they lose their concentration. The noise related to movement of train wheels on rail was reported as the worst by 83.2% followed by the noise of brakes (74.3%) and the ventilation noise (71.9%). 56.9% of conductors reported that they are suffering from sleeplessness, 40.1% from tinnitus and 80.2% feeling fatigue and sleepy. The study results showed the high level of noise and noise annoyance among train conductors and the poor health outcome of their exposure to this level of noise.

  15. Adsorber fires

    International Nuclear Information System (INIS)

    Holmes, W.

    1987-01-01

    The following conclusions are offered with respect to activated charcoal filter systems in nuclear power plants: (1) The use of activated charcoal in nuclear facilities presents a potential for deep-seated fires. (2) The defense-in-depth approach to nuclear fire safety requires that if an ignition should occur, fires must be detected quickly and subsequently suppressed. (3) Deep-seated fires in charcoal beds are difficult to extinguish. (4) Automatic water sprays can be used to extinguish fires rapidly and reliably when properly introduced into the burning medium. The second part of the conclusions offered are more like challenges: (1) The problem associated with inadvertent actuations of fire protection systems is not a major one, and it can be reduced further by proper design review, installation, testing, and maintenance. Eliminating automatic fire extinguishing systems for the protection of charcoal adsorbers is not justified. (2) Removal of automatic fire protection systems due to fear of inadvertent fire protection system operation is a case of treating the effect rather than the cause. On the other hand, properly maintaining automatic fire protection systems will preserve the risk of fire loss at acceptable levels while at the same time reducing the risk of damage presented by inadvertent operation of fire protection systems

  16. Possibilities of reduction of the on-board energy for an innovative subway

    OpenAIRE

    Allègre, A-L.; Barrade, P.; Delarue, P.; Bouscayrol, A.; Chattot, E.; El-Fassi, S.

    2009-01-01

    An innovative subway has been proposed using supercapacitors as energy source. In this paper, are presented different possibilities to reduce on-board stored energy in order to downsize the on-board energy storage subsystem. Special attention is paid to the influence of a feeding rail extension or a downward slope at the beginning of the interstation on the on-board stored energy. A map is built to facilitate the selection of the solution which leads to reduce the on-board energy.

  17. Strength Analysis and Process Simulation of Subway Contact Rail Support Bracket of Composite Materials

    Science.gov (United States)

    Fedulov, Boris N.; Safonov, Alexander A.; Sergeichev, Ivan V.; Ushakov, Andrey E.; Klenin, Yuri G.; Makarenko, Irina V.

    2016-10-01

    An application of composites for construction of subway brackets is a very effective approach to extend their lifetime. However, this approach involves the necessity to prevent process-induced distortions of the bracket due to thermal deformation and chemical shrinkage. At present study, a process simulation has been carried out to support the design of the production tooling. The simulation was based on the application of viscoelastic model for the resin. Simulation results were verified by comparison with results of manufacturing experiments. To optimize the bracket structure the strength analysis was carried out as well.

  18. A Study on Characteristics of Atmospheric Heavy Metals in Subway Station

    Science.gov (United States)

    Kim, Chun-Huem; Yoo, Dong-Chul; Kwon, Young-Min; Han, Woong-Soo; Kim, Gi-Sun; Park, Mi-Jung; Kim, Young Soon

    2010-01-01

    In this study, we investigated the atmospheric heavy metal concentrations in the particulate matter inside the subway stations of Seoul. In particular, we examined the correlation between the heavy metals and studied the effect of the heavy metals on cell proliferation. In six selected subway stations in Seoul, particulate matter was captured at the platforms and 11 types of heavy metals were analyzed. The results showed that the mean concentration of iron was the highest out of the heavy metals in particulate matter, followed by copper, potassium, calcium, zinc, nickel, sodium, manganese, magnesium, chromium and cadmium in that order. The correlation analysis showed that the correlations between the heavy metals was highest in the following order: (Cu vs Zn) , (Ca vs Na) , (Ca vs Mn) , (Ni vs Cr) , (Na vs Mn) , (Cr vs Cd) , (Zn vs Cd) , (Cu vs Cd) , (Ni vs Cd) , (Cu vs Ni) , (K vs Zn) , (Cu vs K) , (Cu vs Cr) , (K vs Cd) , (Zn vs Cr) , (K vs Ni) , (Zn vs Ni) , (K vs Cr) , and (Fe vs Cu) . The correlation coefficient between zinc and copper was 0.937, indicating the highest correlation. Copper, zinc, nickel, chromium and cadmium, which are generated from artificial sources in general, showed correlations with many of the other metals and the correlation coefficients were also relatively high. The effect of the heavy metals on cell proliferation was also investigated in this study. Cultured cell was exposed to 10 mg/l or 100 mg/l of iron, copper, calcium, zinc, nickel, manganese, magnesium, chromium and cadmium for 24 hours. The cell proliferation in all the heavy metal-treated groups was not inhibited at 10 mg/l of the heavy metal concentration. The only exception to this was with the cadmium-treated group which showed a strong cell proliferation inhibition. This study provides the fundamental data for the understanding of simultaneous heavy metal exposure tendency at the time of particulate matter exposure in subway stations and the identification of heavy metal

  19. Research on Matrix-type Packet Loss Compensation Scheme for Wireless Video Transmission on Subway

    Directory of Open Access Journals (Sweden)

    Fan Qing-Wu

    2017-01-01

    Full Text Available As the mainstream wireless LAN technology, Wi-Fi can achieve fast data transfer. With the subway moving in a high speed, video data transmission between the metro and the ground is achieved through Wi-Fi technology. This paper aims at solving the Caton problem caused by switching packet loss in the process of playing real-time video on the train terminal, and proposes matrix-type packet loss compensation scheme. Finally, the feasibility of the scheme is verified by experiments.

  20. Stray current monitoring at Nuremberg subway; Streustromueberwachung bei der U-Bahn Nuernberg

    Energy Technology Data Exchange (ETDEWEB)

    Altmann, M.; Halfmann, U.; Schneider, E. [Siemens AG, Erlangen (Germany). TS EL EN 2; Roesch, N. [VAG Verkehrs-AG Nuernberg, FA/SA - Starkstromanlagen, Nuernberg (Germany)

    2004-05-01

    Operating DC traction systems requires protective measures against the effects of stray currents. Damage by corrosion could occur both at railway and third party installations. The continuous effectiveness of protective measures needs to be monitored and recorded during revenue operation, and shall be capable to be demonstrated to supervising authorities. Measuring the rail-to-earth potential within the traction network under operational conditions, combined with centralized analysis, visualization, signaling and archiving is a straightforward and efficient method of stray current monitoring. For more than one year, the stray current monitoring system SITRAS SMS {sup registered} has been undergoing successful field application at the Nuremberg Subway. (orig.)

  1. Prevention of pedestrian accidents.

    OpenAIRE

    Kendrick, D

    1993-01-01

    Child pedestrian accidents are the most common road traffic accident resulting in injury. Much of the existing work on road traffic accidents is based on analysing clusters of accidents despite evidence that child pedestrian accidents tend to be more dispersed than this. This paper analyses pedestrian accidents in 573 children aged 0-11 years by a locally derived deprivation score for the years 1988-90. The analysis shows a significantly higher accident rate in deprived areas and a dose respo...

  2. Modelling of Fire in an Open Car Park

    DEFF Research Database (Denmark)

    Marton, Timea; Dederichs, Anne Simone; Giuliani, Luisa

    2015-01-01

    Steel car parks exhibit high vulnerability to fire, as a consequence of the degradation of the steel mechanical properties at high temperatures and of the combustible type and amount. Real fire accidents in open car parks demonstrated a much faster and extended fire spread than predictions......, assuming that a fire spread rate of 12 min and consider at most 3-4 vehicles on fire at the same time. Fire Dynamic Simulator (FDS) is applied in this current paper to study fire spread between cars. The outcomes of the investigations show that the fire spread is strongly influenced by the geometrical...... layout and that the distance between cars plays a determinant role on the fire spread rate and ignition of adjacent cars. In particular it was found that the fire spread can be faster than 12 minutes in the case of the cars parked 40 and 60 cm from each other....

  3. US Fire Administration Fire Statistics

    Data.gov (United States)

    Department of Homeland Security — The U.S. Fire Administration collects data from a variety of sources to provide information and analyses on the status and scope of the fire problem in the United...

  4. Key Characteristics of Combined Accident including TLOFW accident for PSA Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Gyung; Kang, Hyun Gook [KAIST, Daejeon (Korea, Republic of); Yoon, Ho Joon [Khalifa University of Science, Technology and Research, Abu Dhabi (United Arab Emirates)

    2015-05-15

    The conventional PSA techniques cannot adequately evaluate all events. The conventional PSA models usually focus on single internal events such as DBAs, the external hazards such as fire, seismic. However, the Fukushima accident of Japan in 2011 reveals that very rare event is necessary to be considered in the PSA model to prevent the radioactive release to environment caused by poor treatment based on lack of the information, and to improve the emergency operation procedure. Especially, the results from PSA can be used to decision making for regulators. Moreover, designers can consider the weakness of plant safety based on the quantified results and understand accident sequence based on human actions and system availability. This study is for PSA modeling of combined accidents including total loss of feedwater (TLOFW) accident. The TLOFW accident is a representative accident involving the failure of cooling through secondary side. If the amount of heat transfer is not enough due to the failure of secondary side, the heat will be accumulated to the primary side by continuous core decay heat. Transients with loss of feedwater include total loss of feedwater accident, loss of condenser vacuum accident, and closure of all MSIVs. When residual heat removal by the secondary side is terminated, the safety injection into the RCS with direct primary depressurization would provide alternative heat removal. This operation is called feed and bleed (F and B) operation. Combined accidents including TLOFW accident are very rare event and partially considered in conventional PSA model. Since the necessity of F and B operation is related to plant conditions, the PSA modeling for combined accidents including TLOFW accident is necessary to identify the design and operational vulnerabilities.The PSA is significant to assess the risk of NPPs, and to identify the design and operational vulnerabilities. Even though the combined accident is very rare event, the consequence of combined

  5. Event tree analysis of accidents during transport of radioactive materials in Japan

    International Nuclear Information System (INIS)

    Watabe, N.; Shirai, K.; Noguchi, K.; Suzuki, H.; Kinehara, Y.

    1993-01-01

    The Event Tree Method is one of the Probabilistic Safety Assessment Method. It introduces the accident scenario and the results of countermeasures. Therefore, it is effective in determining latent accident scenarios in the transfer. In this report the Event Tree Method is used to study the tunnel fire and its effects are evaluated. And this is the first trail of our Probabilistic Safety Assessment. The Event Tree for determining the early conditions when a car engine catches fire in a tunnel is examined. There are fire extinguishers, tunnel equipments for fire-fighting, fire stations and the heat-resisting property of the container for protecting from the fire. The protection level against the over 800degC-30min. fire accident is 88.3 %. (J.P.N.)

  6. Forest fires

    International Nuclear Information System (INIS)

    Fuller, M.

    1991-01-01

    This book examines the many complex and sensitive issues relating to wildland fires. Beginning with an overview of the fires of 1980s, the book discusses the implications of continued drought and considers the behavior of wildland fires, from ignition and spread to spotting and firestorms. Topics include the effects of weather, forest fuels, fire ecology, and the effects of fire on plants and animals. In addition, the book examines firefighting methods and equipment, including new minimum impact techniques and compressed air foam; prescribed burning; and steps that can be taken to protect individuals and human structures. A history of forest fire policies in the U.S. and a discussion of solutions to fire problems around the world completes the coverage. With one percent of the earth's surface burning every year in the last decade, this is a penetrating book on a subject of undeniable importance

  7. Forest fires in Pennsylvania.

    Science.gov (United States)

    Donald A. Haines; William A. Main; Eugene F. McNamara

    1978-01-01

    Describes factors that contribute to forest fires in Pennsylvania. Includes an analysis of basic statistics; distribution of fires during normal, drought, and wet years; fire cause, fire activity by day-of-week; multiple-fire day; and fire climatology.

  8. Analysis of Fire Data in Oman

    Directory of Open Access Journals (Sweden)

    K.S. Al-Jabri

    2003-06-01

    Full Text Available The aim of this study is to illustrate the problem of fire accidents in the Sultanate of Oman and their causes in order to find out how the existing data could be used as a base to improve fire resistance, to detect the weak points (vulnerability to fire in existing structures, and to minimize fire occurrences in places where it is high. This will also provide useful recommendations with regard to fire safety including causes, people’s awareness and education, etc.  Fire data in Oman were collected from two sources: The Directorate General of Civil Defence (Public Relations Department and Sultan Qaboos University library. The collected data represent the number of fires in Oman during the last decade.  It also includes fire distribution by type and averages.  The analysis shows that there is a linear increase in the number of fire accidents in the last decade with time.  Many factors are included as potential sources, which are explained in the paper, and suggestions are made for possible control.

  9. Radiation accidents

    International Nuclear Information System (INIS)

    Saenger, E.L.

    1986-01-01

    It is essential that emergency physicians understand ways to manage patients contaminated by radioactive materials and/or exposed to external radiation sources. Contamination accidents require careful surveys to identify the metabolic pathway of the radionuclides to guide prognosis and treatment. The level of treatment required will depend on careful surveys and meticulous decontamination. There is no specific therapy for the acute radiation syndrome. Prophylactic antibodies are desirable. For severely exposed patients treatment is similar to the supportive care given to patients undergoing organ transplantation. For high-dose extremity injury, no methods have been developed to reverse the fibrosing endarteritis that eventually leads to tissue death so frequently found with this type of injury. Although the Three Mile Island episode of March 1979 created tremendous public concern, there were no radiation injuries. The contamination outside the reactor building and the release of radioiodine were negligible. The accidental fuel element meltdown at Chernobyl, USSR, resulted in many cases of acute radiation syndrome. More than 100,000 people were exposed to high levels of radioactive fallout. The general principles outlined here are applicable to accidents of that degree of severity

  10. Chernobyl accident

    International Nuclear Information System (INIS)

    Bar'yakhtar, V.G.

    1995-01-01

    The monograph contains the catastrophe's events chronology, the efficiency assessed of those measures assumed for their localization as well as their environmental and socio-economic impact. Among materials of the monograph the results are presented of research on the radioactive contamination field forming as well as those concerning the investigation of biogeochemical properties of Chernobyl radionuclides and their migration process in the environment of the Ukraine. The data dealing with biological effects of the continued combined internal and external radioactive influence on plants, animals and human health under the circumstances of Chernobyl accident are of the special interest. In order to provide the scientific generalizing information on the medical aspects of Chernobyl catastrophe, the great part of the monograph is allotted to appraise those factors affecting the health of different population groups as well as to depict clinic aspects of Chernobyl events and medico-sanitarian help system. The National Programme of Ukraine for the accident consequences elimination and population social protection assuring for the years 1986-1993 and this Programme concept for the period up to the year 2000 with a special regard of the world community participation there

  11. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal fires during mid-loop operations. Volume 3, Part 1, Main report

    International Nuclear Information System (INIS)

    Musicki, Z.; Chu, T.L.; Yang, J.; Ho, V.; Hou, Y.M.; Lin, J.; Siu, N.

    1994-07-01

    During l989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than fun power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this report is to document the approach utilized in ' the Surry plant and discuss the results obtained. A parallel report for the Grand Gulf plant is prepared by SNL. This study shows that the core-damage frequency during mid-loop operation at the Surry plant is comparable to that of power operation. We recognize that there is very large uncertainty in the human error probabilities in this study. This study identified that only a few. procedures are available for mitigating accidents that may occur during shutdown. Procedures written specifically for shutdown accidents would be useful

  12. Environmental trade-offs of tunnels vs cut-and-cover subways

    Science.gov (United States)

    Walton, M.

    1978-01-01

    Heavy construction projects in cities entail two kinds of cost - internal cost, which can be defined in terms of payments from one set of parties to another, and external cost, which is the cost borne by the community at large as the result of disutilities entailed in construction and operation. Environmental trade-offs involve external costs, which are commonly difficult to measure. Cut-and-cover subway construction probably entails higher external and internal cost than deep tunnel construction in many urban geological environments, but uncertainty concerning the costs and environmental trade-offs of tunneling leads to limited and timid use of tunneling by American designers. Thus uncertainty becomes a major trade-off which works against tunneling. The reverse is true in Sweden after nearly 30 years of subway construction. Econometric methods for measuring external costs exist in principle, but are limited in application. Economic theory based on market pressure does not address the real problem of urban environmental trade-offs. Nevertheless, the problem of uncertainty can be addressed by comparative studies of estimated and as-built costs of cut-and-cover vs tunnel projects and a review of environmental issues associated with such construction. Such a study would benefit the underground construction industry and the design of transportation systems. It would also help solve an aspect of the urban problem. ?? 1978.

  13. Preferred listening levels of mobile phone programs when considering subway interior noise.

    Science.gov (United States)

    Yu, Jyaehyoung; Lee, Donguk; Han, Woojae

    2016-01-01

    Today, people listen to music loud using personal listening devices. Although a majority of studies have reported that the high volume played on these listening devices produces a latent risk of hearing problems, there is a lack of studies on "double noise exposures" such as environmental noise plus recreational noise. The present study measures the preferred listening levels of a mobile phone program with subway interior noise for 74 normal-hearing participants in five age groups (ranging from 20s to 60s). The speakers presented the subway interior noise at 73.45 dB, while each subject listened to three application programs [Digital Multimedia Broadcasting (DMB), music, game] for 30 min using a tablet personal computer with an earphone. The participants' earphone volume levels were analyzed using a sound level meter and a 2cc coupler. Overall, the results showed that those in their 20s listened to the three programs significantly louder with DMB set at significantly higher volume levels than for the other programs. Higher volume levels were needed for middle frequency compared to the lower and higher frequencies. We concluded that any potential risk of noise-induced hearing loss for mobile phone users should be communicated when users listen regularly, although the volume level was not high enough that the users felt uncomfortable. When considering individual listening habits on mobile phones, further study to predict total accumulated environmental noise is still needed.

  14. Automatic Crack Detection and Classification Method for Subway Tunnel Safety Monitoring

    Directory of Open Access Journals (Sweden)

    Wenyu Zhang

    2014-10-01

    Full Text Available Cracks are an important indicator reflecting the safety status of infrastructures. This paper presents an automatic crack detection and classification methodology for subway tunnel safety monitoring. With the application of high-speed complementary metal-oxide-semiconductor (CMOS industrial cameras, the tunnel surface can be captured and stored in digital images. In a next step, the local dark regions with potential crack defects are segmented from the original gray-scale images by utilizing morphological image processing techniques and thresholding operations. In the feature extraction process, we present a distance histogram based shape descriptor that effectively describes the spatial shape difference between cracks and other irrelevant objects. Along with other features, the classification results successfully remove over 90% misidentified objects. Also, compared with the original gray-scale images, over 90% of the crack length is preserved in the last output binary images. The proposed approach was tested on the safety monitoring for Beijing Subway Line 1. The experimental results revealed the rules of parameter settings and also proved that the proposed approach is effective and efficient for automatic crack detection and classification.

  15. Stress state in the neighborhood of subways and pipe lines under the action of dynamic loads

    International Nuclear Information System (INIS)

    Alexeyeva, L.A.; Eskalieva, A.Z.; Shershnev, V.V.

    2001-01-01

    We consider the long underground constructions of deep and shallow types such as transport subways, mines, underground pipes etc. by the action of dynamic lads. Situated in areas of seismic activity, they are subjected to the influence of seismic waves during earthquakes and can be destroyed. Running loads inside constructions (transport for instance) affect upon toughness and stability of both subways and surrounding medium. If underground construction dispose near a day's surface, it acts also on nearby buildings. Evaluations of behavior of underground and pipes under dynamic influences in real conditions of usage are determined of stress state of constructions in the interaction with environment medium. Here underground constructions are simulated by infinitely long cylindrical cavities in utter ambience. As utter ambience the isotropic elastic medium and two-component medium of Biot are researched. Last one allows simulating saturated water oils. The elastic cylindrical shell simulates supporting of a tunnel (or pipeline). Both a tress state of construction and surrounding medium were investigated for a different contact conditions between support of tunnel and environment (rigid, slippery and viscous contacts). (author)

  16. Large eddy simulation of cooling flows in underground subway station according to different PSD operating conditions

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Yong Jun; Kim, Jin Ho; Park, Sung Huk; Koo, Dong Hoe [Korea Railroad Research Institute, Uiwang (Korea, Republic of)

    2015-11-15

    Large eddy simulation (LES) method is applied to systematically investigate the cooling fluid flow and the temperature distribution under the operating of air conditioning in the deeply underground subway station. The Shin-Gum-Ho subway station in Seoul which is the 8{sup th} floor and 43.6 m deep is selected for this analysis. The entire station is covered for simulation. The ventilation mode for air conditioning is kept as ordinary state. Different operating conditions for Platform screen door (PSD) are applied. First one is PSD is completely close and second one is PSD is regularly open and close which imitate the actual circumstances in the platform. The ventilation diffusers are modeled as 95 square shapes in the lobby and 222 squares in the platform. The temperature variations and flow behaviors are numerically simulated after operating of air conditioning for the whole station and the calculated results are compared with experimental data. LES method solves the momentum and thermal equations. Werner-Wengle wall law is applied to viscous sub layers for near wall resolution. The total grid numbers are 7.5 million and the whole domain is divided to 22 blocks. Multi blocks are computed in parallel using MPI. The results show the temperature difference in the platform between PSD-close and PSD-regularly open and close cases is 3-4 .deg. C.

  17. Preferred listening levels of mobile phone programs when considering subway interior noise

    Directory of Open Access Journals (Sweden)

    Jyaehyoung Yu

    2016-01-01

    Full Text Available Today, people listen to music loud using personal listening devices. Although a majority of studies have reported that the high volume played on these listening devices produces a latent risk of hearing problems, there is a lack of studies on "double noise exposures" such as environmental noise plus recreational noise. The present study measures the preferred listening levels of a mobile phone program with subway interior noise for 74 normal-hearing participants in five age groups (ranging from 20s to 60s. The speakers presented the subway interior noise at 73.45 dB, while each subject listened to three application programs [Digital Multimedia Broadcasting (DMB, music, game] for 30 min using a tablet personal computer with an earphone. The participants′ earphone volume levels were analyzed using a sound level meter and a 2cc coupler. Overall, the results showed that those in their 20s listened to the three programs significantly louder with DMB set at significantly higher volume levels than for the other programs. Higher volume levels were needed for middle frequency compared to the lower and higher frequencies. We concluded that any potential risk of noise-induced hearing loss for mobile phone users should be communicated when users listen regularly, although the volume level was not high enough that the users felt uncomfortable. When considering individual listening habits on mobile phones, further study to predict total accumulated environmental noise is still needed.

  18. Alcohol advertising at Boston subway stations: an assessment of exposure by race and socioeconomic status.

    Science.gov (United States)

    Gentry, Elisabeth; Poirier, Katie; Wilkinson, Tiana; Nhean, Siphannay; Nyborn, Justin; Siegel, Michael

    2011-10-01

    We investigated the frequency of alcohol ads at all 113 subway and streetcar stations in Boston and the patterns of community exposure stratified by race, socioeconomic status, and age. We assessed the extent of alcohol advertising at each station in May 2009. We measured gross impressions and gross rating points (GRPs) for the entire Greater Boston population and for Boston public school student commuters. We compared the frequency of alcohol advertising between neighborhoods with differing demographics. For the Greater Boston population, alcohol advertising at subway stations generated 109 GRPs on a typical day. For Boston public school students in grades 5 to 12, alcohol advertising at stations generated 134 GRPs. Advertising at stations in low-poverty neighborhoods generated 14.1 GRPs and at stations in high-poverty areas, 63.6 GRPs. Alcohol ads reach the equivalent of every adult in the Greater Boston region and the equivalent of every 5th- to 12th-grade public school student each day. More alcohol ads were displayed in stations in neighborhoods with high poverty rates than in stations in neighborhoods with low poverty rates.

  19. Automatic crack detection and classification method for subway tunnel safety monitoring.

    Science.gov (United States)

    Zhang, Wenyu; Zhang, Zhenjiang; Qi, Dapeng; Liu, Yun

    2014-10-16

    Cracks are an important indicator reflecting the safety status of infrastructures. This paper presents an automatic crack detection and classification methodology for subway tunnel safety monitoring. With the application of high-speed complementary metal-oxide-semiconductor (CMOS) industrial cameras, the tunnel surface can be captured and stored in digital images. In a next step, the local dark regions with potential crack defects are segmented from the original gray-scale images by utilizing morphological image processing techniques and thresholding operations. In the feature extraction process, we present a distance histogram based shape descriptor that effectively describes the spatial shape difference between cracks and other irrelevant objects. Along with other features, the classification results successfully remove over 90% misidentified objects. Also, compared with the original gray-scale images, over 90% of the crack length is preserved in the last output binary images. The proposed approach was tested on the safety monitoring for Beijing Subway Line 1. The experimental results revealed the rules of parameter settings and also proved that the proposed approach is effective and efficient for automatic crack detection and classification.

  20. Automated As-Built Model Generation of Subway Tunnels from Mobile LiDAR Data

    Directory of Open Access Journals (Sweden)

    Mostafa Arastounia

    2016-09-01

    Full Text Available This study proposes fully-automated methods for as-built model generation of subway tunnels employing mobile Light Detection and Ranging (LiDAR data. The employed dataset is acquired by a Velodyne HDL 32E and covers 155 m of a subway tunnel containing six million points. First, the tunnel’s main axis and cross sections are extracted. Next, a preliminary model is created by fitting an ellipse to each extracted cross section. The model is refined by employing residual analysis and Baarda’s data snooping method to eliminate outliers. The final model is then generated by applying least squares adjustment to outlier-free data. The obtained results indicate that the tunnel’s main axis and 1551 cross sections at 0.1 m intervals are successfully extracted. Cross sections have an average semi-major axis of 7.8508 m with a standard deviation of 0.2 mm and semi-minor axis of 7.7509 m with a standard deviation of 0.1 mm. The average normal distance of points from the constructed model (average absolute error is also 0.012 m. The developed algorithm is applicable to tunnels with any horizontal orientation and degree of curvature since it makes no assumptions, nor does it use any a priori knowledge regarding the tunnel’s curvature and horizontal orientation.

  1. Predictive monitoring and diagnosis of periodic air pollution in a subway station.

    Science.gov (United States)

    Kim, YongSu; Kim, MinJung; Lim, JungJin; Kim, Jeong Tai; Yoo, ChangKyoo

    2010-11-15

    The purpose of this study was to develop a predictive monitoring and diagnosis system for the air pollutants in a subway system using a lifting technique with a multiway principal component analysis (MPCA) which monitors the periodic patterns of the air pollutants and diagnoses the sources of the contamination. The basic purpose of this lifting technique was to capture the multivariate and periodic characteristics of all of the indoor air samples collected during each day. These characteristics could then be used to improve the handling of strong periodic fluctuations in the air quality environment in subway systems and will allow important changes in the indoor air quality to be quickly detected. The predictive monitoring approach was applied to a real indoor air quality dataset collected by telemonitoring systems (TMS) that indicated some periodic variations in the air pollutants and multivariate relationships between the measured variables. Two monitoring models--global and seasonal--were developed to study climate change in Korea. The proposed predictive monitoring method using the lifted model resulted in fewer false alarms and missed faults due to non-stationary behavior than that were experienced with the conventional methods. This method could be used to identify the contributions of various pollution sources. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Rush-hour aromatic and chlorinated hydrocarbons in selected subway stations of Shanghai, China.

    Science.gov (United States)

    Zhang, Yanli; Li, Chunlei; Wang, Xinming; Guo, Hai; Feng, Yanli; Chen, Jianmin

    2012-01-01

    Air samples were collected simultaneously at platform, mezzanine and outdoor in five typical stations of subway system in Shanghai, China using stainless steel canisters and analyzed by gas chromatography-mass selective detector (GC-MSD) after cryogenic preconcentration. Benzene, toluene, ethylbenzene and xylenes (BTEX) at the platforms and mezzanines inside the stations averaged (10.3 +/- 2.1), (38.7 +/- 9.0), (19.4 +/- 10.1) and (30.0 +/- 11.1) microg/m3, respectively; while trichloroethylene (TrCE), tetrachloroethylene (TeCE) and para-dichlorobenzene (pDCB), vinyl chloride and carbon tetrachloride were the most abundant chlorinated hydrocarbons inside the stations with average levels of (3.6 +/- 1.3), (1.3 +/- 0.5), (4.1 +/- 1.1), (2.2 +/- 1.1) and (1.2 +/- 0.3) microg/m3, respectively. Mean levels of major aromatic and chlorinated hydrocarbons were higher indoor (platforms and mezzanines) than outdoor with average indoor/outdoor (I/O) ratios of 1.1-9.5, whereas no significant indoor/outdoor differences were found except for benzene and TrCE. The highly significant mutual correlations (p subway stations from indoor/outdoor air exchange and traffic emission should be their dominant source. TrCE and pDCB were mainly from indoor emission and TeCE might have both indoor emission sources and contribution from outdoor air, especially in the mezzanines.

  3. Large eddy simulation of cooling flows in underground subway station according to different PSD operating conditions

    International Nuclear Information System (INIS)

    Jang, Yong Jun; Kim, Jin Ho; Park, Sung Huk; Koo, Dong Hoe

    2015-01-01

    Large eddy simulation (LES) method is applied to systematically investigate the cooling fluid flow and the temperature distribution under the operating of air conditioning in the deeply underground subway station. The Shin-Gum-Ho subway station in Seoul which is the 8"t"h floor and 43.6 m deep is selected for this analysis. The entire station is covered for simulation. The ventilation mode for air conditioning is kept as ordinary state. Different operating conditions for Platform screen door (PSD) are applied. First one is PSD is completely close and second one is PSD is regularly open and close which imitate the actual circumstances in the platform. The ventilation diffusers are modeled as 95 square shapes in the lobby and 222 squares in the platform. The temperature variations and flow behaviors are numerically simulated after operating of air conditioning for the whole station and the calculated results are compared with experimental data. LES method solves the momentum and thermal equations. Werner-Wengle wall law is applied to viscous sub layers for near wall resolution. The total grid numbers are 7.5 million and the whole domain is divided to 22 blocks. Multi blocks are computed in parallel using MPI. The results show the temperature difference in the platform between PSD-close and PSD-regularly open and close cases is 3-4 .deg. C

  4. Research on dynamic creep strain and settlement prediction under the subway vibration loading.

    Science.gov (United States)

    Luo, Junhui; Miao, Linchang

    2016-01-01

    This research aims to explore the dynamic characteristics and settlement prediction of soft soil. Accordingly, the dynamic shear modulus formula considering the vibration frequency was utilized and the dynamic triaxial test conducted to verify the validity of the formula. Subsequently, the formula was applied to the dynamic creep strain function, with the factors influencing the improved dynamic creep strain curve of soft soil being analyzed. Meanwhile, the variation law of dynamic stress with sampling depth was obtained through the finite element simulation of subway foundation. Furthermore, the improved dynamic creep strain curve of soil layer was determined based on the dynamic stress. Thereafter, it could to estimate the long-term settlement under subway vibration loading by norms. The results revealed that the dynamic shear modulus formula is straightforward and practical in terms of its application to the vibration frequency. The values predicted using the improved dynamic creep strain formula closed to the experimental values, whilst the estimating settlement closed to the measured values obtained in the field test.

  5. Attack in a subway by an explosive containing radioactive substance. Specificities of the taking charge and assistance organization

    International Nuclear Information System (INIS)

    Curet, P.M.

    1999-01-01

    The use of explosives with radioactive material in them during an attack in the subway obliges several specificities in the help organisation, in the taking charge of victims and in the environmental management for the broadest meaning. That is the purpose of this article. (N.C.)

  6. Effects of Experimentally Imposed Noise on Task Performance of Black Children Attending Day Care Centers Near Elevated Subway Trains.

    Science.gov (United States)

    Hambrick-Dixon, Priscilla Janet

    1986-01-01

    Investigates whether an experimentally imposed 80dB (A) noise affected psychomotor, serial memory words and pictures, incidental memory, visual recall, paired associates, perceptual learning, and coding performance of five-year-old Black children attending day care centers near and far from elevated subways. (HOD)

  7. Vulnerability effects of passengers' intermodal transfer distance preference and subway expansion on complementary urban public transportation systems

    International Nuclear Information System (INIS)

    Hong, Liu; Yan, Yongze; Ouyang, Min; Tian, Hui; He, Xiaozheng

    2017-01-01

    The vulnerability studies on urban public transportation systems have attracted growing attentions in recent years, due to their important role in the economy development of a city and the well-beings of its citizens. This paper proposes a vulnerability model of complementary urban public transportation systems (CUPTSs) composed of bus systems and subway systems, with the consideration of passengers’ intermodal transfer distance preference (PITDP) to capture different levels of complementary strength between the two systems. Based on the model, this paper further introduces a CUPTSs-aimed vulnerability analysis method from two specific aspects: (a) vulnerability effects of different PITDP values, which facilitate the design of policies to change PITDP to reduce system vulnerability; (b) vulnerability effects of different subway expansion plans, which facilitate the vulnerability investigation of current expansion plan and the identification of the optimal expansion plan from the system vulnerability perspective. The proposed CUPTSs-aimed vulnerability analysis method is applied to investigate the complementary bus and subway systems in the city of Wuhan, China. The insights from this study are helpful to analyze other CUPTSs for valuable planning suggestions from the vulnerability perspective. - Highlights: • We model complementary urban public transportation systems’ (CUPTSs) vulnerability. • We use a PITDP metric to capture different levels of complementary relationship. • We study vulnerability under different PITDP and different subway expansion plans. • We analyze dynamic vulnerability of CUPTSs during their expansion process.

  8. Origin of polycyclic aromatic hydrocarbons and other organic pollutants in the air particles of subway stations in Barcelona.

    Science.gov (United States)

    van Drooge, Barend L; Prats, Raimon M; Reche, Cristina; Minguillón, MariCruz; Querol, Xavier; Grimalt, Joan O; Moreno, Teresa

    2018-06-09

    Underground subways transport large numbers of citizens in big cities, which must breathe air with limited ventilation. These atmospheric conditions may enhance the concentration of air pollutants from both outdoor and indoor air. The influence of ventilation conditions and maintenance activities on the concentrations of air pollutants have been studied. Particulate matter with aerodynamic diameter smaller than 2.5 μm (PM 2.5 ) in indoor air was sampled in ten platforms of nine subway stations of the metropolitan area of Barcelona in 2015 and 2016. These particles were analyzed for polycyclic aromatic hydrocarbons (PAH) and organic tracer compounds. The concentrations of PAH were in the range of the street air levels with higher PAH values in the colder period. No influence of nighttime maintenance activities was observed on the platform air quality during daytime. Source apportionment analysis using the concentrations of hopanes, nicotine and levoglucosan as molecular tracer compounds showed that 75% of the detected PAH at the platforms have an outdoor PM origin. The modern subway stations, with advanced ventilation and platform screen doors that separate the subway system from the platform, showed lowest PAH and PM concentrations. Copyright © 2018. Published by Elsevier B.V.

  9. Transmission characteristics of Bessel-Gaussian vortex beams propagating along both longitudinal and transverse directions in a subway tunnel

    Science.gov (United States)

    Wang, Xiaohui; Song, Yingxiong

    2018-02-01

    By exploiting the non-Kolmogorov model and Rytov approximation theory, a propagation model of Bessel-Gaussian vortex beams (BGVB) propagating in a subway tunnel is derived. Based on the propagation model, a model of orbital angular momentum (OAM) mode probability distribution is established to evaluate the propagation performance when the beam propagates along both longitudinal and transverse directions in the subway tunnel. By numerical simulations and experimental verifications, the influences of the various parameters of BGVB and turbulence on the OAM mode probability distribution are evaluated, and the results of simulations are consistent with the experimental statistics. The results verify that the middle area of turbulence is more beneficial for the vortex beam propagation than the edge; when the BGVB propagates along the longitudinal direction in the subway tunnel, the effects of turbulence on the OAM mode probability distribution can be decreased by selecting a larger anisotropy parameter, smaller coherence length, larger non-Kolmogorov power spectrum coefficient, smaller topological charge number, deeper subway tunnel, lower train speed, and longer wavelength. When the BGVB propagates along the transverse direction, the influences can be also mitigated by adopting a larger topological charge number, less non-Kolmogorov power spectrum coefficient, smaller refractive structure index, shorter wavelength, and shorter propagation distance.

  10. Outline of Fukushima nuclear accident and future action. Lessons learned from accident and countermeasure plan

    International Nuclear Information System (INIS)

    Fukuda, Toshihiko

    2012-01-01

    Fukushima nuclear accident was caused by loss of all AC power sources (SBO) and loss of ultimate heat sink (LUHS) at Fukushima Daiichi Nuclear Power Plants (NPPs) hit by the Great East Japan Earthquake. This article reviewed outline of Fukushima nuclear accident progression when on year had passed since and referred to lessons learned from accident and countermeasure plan to prevent severe accident in SBO and LUHS events by earthquake and tsunami as future action. This countermeasure would be taken to (1) prevent serious flooding in case a tsunami overwhelms the breakwater, with improving water tightness of rooms for emergency diesel generator, batteries and power centers, (2) enhance emergency power supply and cooling function with mobile electricity generator, high pressure fire pump car and alternate water supply source, (3) mitigate environmental effects caused by core damage with installing containment filtered venting, and (4) enforce emergency preparedness in case of severe accident. Definite countermeasure plan for Kashiwazaki-Kariwa NPPs was enumerated. (T. Tanaka)

  11. 46 CFR 28.820 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.820 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel must be equipped with a self-priming, power driven fire...

  12. The end of the line: The relationship between New York City's subway system and residential class structure

    Science.gov (United States)

    Rhindress, Mindy

    Public money is necessary to build and maintain this country's vast network of mass transit systems and highways. Thus you would expect class equity in choices of infrastructure location, types of projects and pricing. However, the influence of commercial interests appears to create a contradictory effect, and may negatively influence the settlement patterns where transit serves. New York City and its subway system offered the perfect case study by which to examine the before and after effects of mass transit introduction given the enormous size of the transit system and the grand development of New York City that appeared to occur simultaneous to subway inauguration. The main objective of this study was to determine the relationship between the growth of the New York City subway system and the establishment of class structure in residential patterns. Regional census data covering the first 16-year period of the subway's development was examined along with geographic statistics on subway line expansion and station openings. GIS (Geographic Information Systems) maps were used to illustrate the development of living spaces as a function of subway introduction into communities, and several Indices were computed to demonstrate the population growth and class disparity. The results revealed that the early years of transit development were entrepreneurial efforts coordinated by business interests. This led to transit first providing significant benefits mostly to the middle and upper classes, giving them a reasonable means by which to escape horrible tenement living conditions while turning a profit at the same time. Thus new settlements were stratified by class almost immediately after introduction. The cycle continued until years later when the automobile was introduced and the once expensive and luxurious, but now more reasonably priced and just functional, public transit system finally befit the population much lower on the socioeconomic scale. Class divisions still

  13. Wildland fire limits subsequent fire occurrence

    Science.gov (United States)

    Sean A. Parks; Carol Miller; Lisa M. Holsinger; Scott Baggett; Benjamin J. Bird

    2016-01-01

    Several aspects of wildland fire are moderated by site- and landscape-level vegetation changes caused by previous fire, thereby creating a dynamic where one fire exerts a regulatory control on subsequent fire. For example, wildland fire has been shown to regulate the size and severity of subsequent fire. However, wildland fire has the potential to influence...

  14. Chernobyl accident

    International Nuclear Information System (INIS)

    Capra, D.; Facchini, U.; Gianelle, V.; Ravasini, G.; Bacci, P.

    1988-01-01

    The radioactive cloud released during the Chernobyl accident reached the Padana plain and Lombardy in the night of April 30th 1986; the cloud remained in the northern Italian skies for a few days and then disappeared either dispersed by winds and washed by rains. The evidence in atmosphere of radionuclides as Tellurium, Iodine, Cesium, was promptly observed. The intense rain, in first week of may, washed the radioactivity and fall-out contamined the land, soil, grass. The present work concerns the overall contamination of the Northern Italy territory and in particular the radioactive fall-out in the Lakes region. Samples of soil have been measured at the gamma spectroscope; a correlation is found between the radionuclides concentration in soil samples and the rain intensity, when appropriate deposition models are considered. A number of measurements has been done on the Como'lake ecosystem: sediments, plankton, fishes and the overall fall-out in the area has been investigated

  15. Deepwater Horizon Accident Investigation Report

    International Nuclear Information System (INIS)

    2010-09-01

    On the evening of April 20, 2010, a well control event allowed hydrocarbons to escape from the Macondo well onto Transocean's Deepwater Horizon, resulting in explosions and fire on the rig. Eleven people lost their lives, and 17 others were injured. The fire, which was fed by hydrocarbons from the well, continued for 36 hours until the rig sank. Hydrocarbons continued to flow from the reservoir through the wellbore and the blowout preventer (BOP) for 87 days, causing a spill of national significance. BP Exploration and Production Inc. was the lease operator of Mississippi Canyon Block 252, which contains the Macondo well. BP formed an investigation team that was charged with gathering the facts surrounding the accident, analyzing available information to identify possible causes and making recommendations to enable prevention of similar accidents in the future. The BP investigation team began its work immediately in the aftermath of the accident, working independently from other BP spill response activities and organizations. The ability to gather information was limited by a scarcity of physical evidence and restricted access to potentially relevant witnesses. The team had access to partial real-time data from the rig, documents from various aspects of the Macondo well's development and construction, witness interviews and testimony from public hearings. The team used the information that was made available by other companies, including Transocean, Halliburton and Cameron. Over the course of the investigation, the team involved over 50 internal and external specialists from a variety of fields: safety, operations, subsea, drilling, well control, cementing, well flow dynamic modeling, BOP systems and process hazard analysis. This report presents an analysis of the events leading up to the accident, eight key findings related to the causal chain of events and recommendations to enable the prevention of a similar accident. The investigation team worked separately

  16. Deepwater Horizon Accident Investigation Report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-09-15

    On the evening of April 20, 2010, a well control event allowed hydrocarbons to escape from the Macondo well onto Transocean's Deepwater Horizon, resulting in explosions and fire on the rig. Eleven people lost their lives, and 17 others were injured. The fire, which was fed by hydrocarbons from the well, continued for 36 hours until the rig sank. Hydrocarbons continued to flow from the reservoir through the wellbore and the blowout preventer (BOP) for 87 days, causing a spill of national significance. BP Exploration and Production Inc. was the lease operator of Mississippi Canyon Block 252, which contains the Macondo well. BP formed an investigation team that was charged with gathering the facts surrounding the accident, analyzing available information to identify possible causes and making recommendations to enable prevention of similar accidents in the future. The BP investigation team began its work immediately in the aftermath of the accident, working independently from other BP spill response activities and organizations. The ability to gather information was limited by a scarcity of physical evidence and restricted access to potentially relevant witnesses. The team had access to partial real-time data from the rig, documents from various aspects of the Macondo well's development and construction, witness interviews and testimony from public hearings. The team used the information that was made available by other companies, including Transocean, Halliburton and Cameron. Over the course of the investigation, the team involved over 50 internal and external specialists from a variety of fields: safety, operations, subsea, drilling, well control, cementing, well flow dynamic modeling, BOP systems and process hazard analysis. This report presents an analysis of the events leading up to the accident, eight key findings related to the causal chain of events and recommendations to enable the prevention of a similar accident. The investigation team worked

  17. Self-reported accidents

    DEFF Research Database (Denmark)

    Møller, Katrine Meltofte; Andersen, Camilla Sloth

    2016-01-01

    The main idea behind the self-reporting of accidents is to ask people about their traffic accidents and gain knowledge on these accidents without relying on the official records kept by police and/or hospitals.......The main idea behind the self-reporting of accidents is to ask people about their traffic accidents and gain knowledge on these accidents without relying on the official records kept by police and/or hospitals....

  18. Unhealthful Food-and-Beverage Advertising in Subway Stations: Targeted Marketing, Vulnerable Groups, Dietary Intake, and Poor Health.

    Science.gov (United States)

    Lucan, Sean C; Maroko, Andrew R; Sanon, Omar C; Schechter, Clyde B

    2017-04-01

    Unhealthful food-and-beverage advertising often targets vulnerable groups. The extent of such advertising in subway stations has not been reported and it is not clear how ad placement may relate to subway ridership or community demographics, or what the implications might be for diets and diet-related health in surrounding communities. Riding all subway lines (n = 7) in the Bronx, NY, USA, investigators systematically assessed all print ads (n = 1586) in all stations (n = 68) in 2012. Data about subway ridership came from the Metropolitan Transportation Authority. Demographic data on surrounding residential areas came from the U.S. Census Bureau. Data on dietary intake and diet-related conditions came from a city health-department survey. There were no ads promoting "more-healthful" food-or-beverage items (i.e., fruits, vegetables, whole grains, nuts, water or milk). There were many ads for "less-healthful" items (e.g., candies, chips, sugary cereals, frozen pizzas, "energy" drinks, coffee confections, hard alcohol, and beer). Ad placement did not relate to the number of riders entering at stations. Instead, exposure to food-or-beverage ads generally, and to "less-healthful" ads particularly (specifically ads in Spanish, directed at youth, and/or featuring minorities), was directly correlated with poverty, lower high-school graduation rates, higher percentages of Hispanics, and/or higher percentages of children in surrounding residential areas. Correlations were robust to sensitivity analyses. Additional analyses suggested correlations between ad exposures and sugary-drink consumption, fruit-and-vegetable intake, and diabetes, hypertension, and high-cholesterol rates. Subway-station ads for "less-healthful" items were located disproportionately in areas home to vulnerable populations facing diet and diet-related-health challenges. The fact that uneven ad placement did not relate to total rider counts suggests ads were not directed at the largest

  19. Dose estimates in a loss of lead shielding truck accident.

    Energy Technology Data Exchange (ETDEWEB)

    Dennis, Matthew L.; Osborn, Douglas M.; Weiner, Ruth F.; Heames, Terence John (Alion Science & Technology Albuquerque, NM)

    2009-08-01

    The radiological transportation risk & consequence program, RADTRAN, has recently added an updated loss of lead shielding (LOS) model to it most recent version, RADTRAN 6.0. The LOS model was used to determine dose estimates to first-responders during a spent nuclear fuel transportation accident. Results varied according to the following: type of accident scenario, percent of lead slump, distance to shipment, and time spent in the area. This document presents a method of creating dose estimates for first-responders using RADTRAN with potential accident scenarios. This may be of particular interest in the event of high speed accidents or fires involving cask punctures.

  20. Accident Assessment

    International Nuclear Information System (INIS)

    Tripputi, Ivo; Lund, Ingemar

    2002-01-01

    There is a general feeling that decommissioning is an activity involving limited risks, compared to NPP operation, and in particular risks involving the general public. This is technically confirmed by licensing analysis and evaluations, where, once the spent fuel has been removed from the plant, the radioactivity inventory available to be released to the environment is very limited. Decommissioning activities performed so far in the world have also confirmed the first assumptions and no specific issue has been identified, in this field, to justify a completely new approach. Commercial interests in international harmonization, which could drive an in-depth discussion about the bases of this approach, are weak at the moment. However, there are several reasons why a discussion in an international framework about the Safety Case for decommissioning (and, in particular, about Accident Assessment) may be considered necessary and important, and why it may show some specific and peculiar aspects. An effort for a comprehensive and systematic D and D accident safety assessment of the decommissioning process is justified. It is necessary also to explore in a holistic way the aspects of industrial safety, and develop tools for the decision-making process optimization. The expected results are the implementation of appropriate and optimized protective measures in any event and of adequate on/off-site emergency plans for optimal public and workers protection. The experience from other decommissioning projects and large-scale industrial activities is essential to balance provisions and an Operating Experience review process (specific for decommissioning) should help to focus on real issues

  1. Simulation and Damage Analysis of an Accidental Jet Fire in a High-Pressure Compressed Pump Shelter

    OpenAIRE

    Jang, Chang Bong; Choi, Sang-Won

    2016-01-01

    Background: As one of the most frequently occurring accidents in a chemical plant, a fire accident may occur at any place where transfer or handling of combustible materials is routinely performed. Methods: In particular, a jet fire incident in a chemical plant operated under high pressure may bring severe damage. To review this event numerically, Computational Fluid Dynamics methodology was used to simulate a jet fire at a pipe of a compressor under high pressure. Results: For jet fire...

  2. Experience from the Inspection of Licensees' Outage Activities, Including Fire Protection Programmes, Event Response Inspections, and the Impact of the Fukushima Daiichi NPP Accident on Inspection Programmes. Workshop Proceedings, Chattanooga, Tennessee, United States, 7-10 April 2014

    International Nuclear Information System (INIS)

    2014-10-01

    The main purpose of the workshop was to provide a forum of exchange of information on the regulatory inspection activities. Participants had the opportunity to meet with their counterparts from other countries and organisations to discuss current and future issues on the selected topics. They developed conclusions regarding these issues and hopefully, identified methods to help improve their own inspection programmes. The NEA Committee on Nuclear Regulatory Activities (CNRA) believes that an essential factor in ensuring the safety of nuclear installations is the continuing exchange and analysis of technical information and data. To facilitate this exchange the Committee has established working groups and groups of experts in specialised topics. The Working Group on Inspection Practices (WGIP) was formed in 1990 with the mandate '..to concentrate on the conduct of inspections and how the effectiveness of inspections could be evaluated..'. The WGIP facilitates the exchange of information and experience related to regulatory safety inspections between CNRA member countries. These proceedings cover the 12. International Workshop held by WGIP on regulatory inspection activities. This workshop, which is the twelfth in a series, along with many other activities performed by the Working Group, is directed towards this goal. The consensus from participants at previous workshops, noted that the value of meeting with people from other inspection organisations was one of the most important achievements. The focus of this workshop was on experience gained from regulatory inspection activities in three areas: - Inspection of Outage Activities Including Fire Protection Programmes. - Event Response Inspections. - The Impact of Inspection Programmes of the Fukushima Daiichi Nuclear Power Plant (NPP) Accident. The main objectives of the WGIP workshops are to enable inspectors to meet with inspectors from other organisations, to exchange information regarding regulatory inspection

  3. Fire prevention in industrial installations presenting a risk for man and environment (ICPE)

    International Nuclear Information System (INIS)

    Moche, L.

    2000-01-01

    The most likely accident in industrial installations is fire. 59 out of 100 accidents reported in 1999 describe a fire outbreak, the fire is either the initiating cause of the accident or the form into which the event eventually evolves. This article briefly describes the why and the wherefore of French regulations on fire prevention in installations presenting a risk for man and environment. The French system is based on the responsibility of the plant operator and on the result of inspections performed by authorities to check the conformity of the installation with current regulations. (A.C.)

  4. Numerical simulation methods of fires in nuclear power plants

    International Nuclear Information System (INIS)

    Keski-Rahkonen, O.; Bjoerkman, J.; Heikkilae, L.

    1992-01-01

    Fire is a significant hazard to the safety of nuclear power plants (NPP). Fire may be serious accident as such, but even small fire at a critical point in a NPP may cause an accident much more serious than fire itself. According to risk assessments a fire may be an initial cause or a contributing factor in a large part of reactor accidents. At the Fire Technology and the the Nuclear Engineering Laboratory of the Technical Research Centre of Finland (VTT) fire safety research for NPPs has been carried out in a large extent since 1985. During years 1988-92 a project Advanced Numerical Modelling in Nuclear Power Plants (PALOME) was carried out. In the project the level of numerical modelling for fire research in Finland was improved by acquiring, preparing for use and developing numerical fire simulation programs. Large scale test data of the German experimental program (PHDR Sicherheitsprogramm in Kernforschungscentral Karlsruhe) has been as reference. The large scale tests were simulated by numerical codes and results were compared to calculations carried out by others. Scientific interaction with outstanding foreign laboratories and scientists has been an important part of the project. This report describes the work of PALOME-project carried out at the Fire Technology Laboratory only. A report on the work at the Nuclear Engineering Laboratory will be published separatively. (au)

  5. On fire

    DEFF Research Database (Denmark)

    Hansen, Helle Rabøl

    The title of this paper: “On fire”, refers to two (maybe three) aspects: firstly as a metaphor of having engagement in a community of practice according to Lave & Wenger (1991), and secondly it refers to the concrete element “fire” in the work of the fire fighters – and thirdly fire as a signifier...

  6. Fire Power

    Science.gov (United States)

    Denker, Deb; West, Lee

    2009-01-01

    For education administrators, campus fires are not only a distressing loss, but also a stark reminder that a campus faces risks that require special vigilance. In many ways, campuses resemble small communities, with areas for living, working and relaxing. A residence hall fire may raise the specter of careless youth, often with the complication of…

  7. 46 CFR 28.315 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... After September 15, 1991, and That Operate With More Than 16 Individuals on Board § 28.315 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel 36 feet (11.8 meters) or more in length must...

  8. Forest-fire models

    Science.gov (United States)

    Haiganoush Preisler; Alan Ager

    2013-01-01

    For applied mathematicians forest fire models refer mainly to a non-linear dynamic system often used to simulate spread of fire. For forest managers forest fire models may pertain to any of the three phases of fire management: prefire planning (fire risk models), fire suppression (fire behavior models), and postfire evaluation (fire effects and economic models). In...

  9. Fire protection at hot laboratories: Prevention, surveillance and fire-fighting

    International Nuclear Information System (INIS)

    Chappellier, A.M.

    1976-01-01

    After pointing out that fire in a hot laboratory can be an important factor contributing to a radioactivity accident, the author briefly recalls the items to be taken into account in a fire hazard analysis. He then describes various important aspects of prevention, detection and fire-fighting which - at the French Commissariat a l'Energie Atomique - are governed by already defined rules or by guidelines which are sufficiently advanced to give a clear idea of the final conclusions to be drawn therefrom. From the point of view protection, the concept of fire sector has been evolved, at hot laboratories, becomes the fire and contamination sector, so as to ensure under all circumstances the containment of any radioactive materials dispersed in the premises on fire. Regarding fire detection, a study should be made on the constraints specific to the facility and liable to affect detector operation. These include ventilation, radiations, neutral or corrosive atmosphere, etc. As regards fire-fighting, two particular aspects are dealt with, namely the question of using water in case of fire and action to be taken concerning ventilation. A practical example - the protection of a ventilation system - is described. In conclusion the paper refers to the need for a thorough analysis specific to each hot laboratory, and to the importance of preparing an operational plan so as to avoid any dangerous improvisations in case of an accident. (author)

  10. A Case Study on Stratified Settlement and Rebound Characteristics due to Dewatering in Shanghai Subway Station

    Directory of Open Access Journals (Sweden)

    Jianxiu Wang

    2013-01-01

    Full Text Available Based on the Yishan Metro Station Project of Shanghai Metro Line number 9, a centrifugal model test was conducted to investigate the behavior of stratified settlement and rebound (SSR of Shanghai soft clay caused by dewatering in deep subway station pit. The soil model was composed of three layers, and the dewatering process was simulated by self-invention of decompressing devise. The results indicate that SSR occurs when the decompression was carried out, and only negative rebound was found in sandy clay, but both positive and negative rebound occurred in the silty clay, and the absolute value of rebound in sandy clay was larger than in silty clay, and the mechanism of SSR was discussed with mechanical sandwich model, and it was found that the load and cohesive force of different soils was the main source of different responses when decompressed.

  11. A case study on stratified settlement and rebound characteristics due to dewatering in Shanghai subway station.

    Science.gov (United States)

    Wang, Jianxiu; Huang, Tianrong; Sui, Dongchang

    2013-01-01

    Based on the Yishan Metro Station Project of Shanghai Metro Line number 9, a centrifugal model test was conducted to investigate the behavior of stratified settlement and rebound (SSR) of Shanghai soft clay caused by dewatering in deep subway station pit. The soil model was composed of three layers, and the dewatering process was simulated by self-invention of decompressing devise. The results indicate that SSR occurs when the decompression was carried out, and only negative rebound was found in sandy clay, but both positive and negative rebound occurred in the silty clay, and the absolute value of rebound in sandy clay was larger than in silty clay, and the mechanism of SSR was discussed with mechanical sandwich model, and it was found that the load and cohesive force of different soils was the main source of different responses when decompressed.

  12. Study on Vibration Reduction Method for a Subway Station in Soft Ground

    Directory of Open Access Journals (Sweden)

    Xian-Feng Ma

    2017-01-01

    Full Text Available With the rapid development of metro system in urban areas, vibration and its impact on adjacent structures caused by metro operation have drawn much attention of researches and worries relating to it have risen. This paper analyzed the vibration attenuation and the environment impact by a case study of a subway station in soft ground with adjacent laboratory building. A method of setting a compound separation barrier surrounding the station is checked and different materials used in the barrier have been tried and tested through numerical analysis. Key parameters of the material and the effects of vibration reduction are studied with the purpose that similar methodology and findings can be referenced in future practices.

  13. [MICROCLIMATE CONDITION IN SUBWAY CARS IN THE SUMMER PERIOD OF THE YEAR].

    Science.gov (United States)

    Leksin, A G; Evlampieva, M N; Timoshenkova, E V; Morgunov, A V; Kaptsov, V A

    2015-01-01

    There are presented the results of the work, which aims to identify the relationship between the temperature of air in the salons of subway cars from the heat output of passengers in different people occupancy of cars during "peak hours", and to determine the efficacy offorced air handling regular ventilation or air conditioning system to remove the elevated heat load on passengers. In the work there was used the method of calculating the amount of heat output of 215 passengers (nominal fullness of the chamber) and the simulation method of heat and moisture output of the same number of passengers. The operating system of ventilation has been shown to fail to decline the average temperature of the air in the passenger compartment to the optimum values and most efficient approach for the reducing the heat load on the passengers is the use of air conditioning systems.

  14. Removal of particulate matter emitted from a subway tunnel using magnetic filters.

    Science.gov (United States)

    Son, Youn-Suk; Dinh, Trieu-Vuong; Chung, Sang-Gwi; Lee, Jai-Hyo; Kim, Jo-Chun

    2014-01-01

    We removed particulate matter (PM) emitted from a subway tunnel using magnetic filters. A magnetic filter system was installed on the top of a ventilation opening. Magnetic field density was increased by increasing the number of permanent magnet layers to determine PM removal characteristics. Moreover, the fan's frequency was adjusted from 30 to 60 Hz to investigate the effect of wind velocity on PM removal efficiency. As a result, PM removal efficiency increased as the number of magnetic filters or fan frequency increased. We obtained maximum removal efficiency of PM10 (52%), PM2.5 (46%), and PM1 (38%) at a 60 Hz fan frequency using double magnetic filters. We also found that the stability of the PM removal efficiency by the double filter (RSD, 3.2-5.8%) was higher than that by a single filter (10.9-24.5%) at all fan operating conditions.

  15. Subway e skyway: infrastrutture sostenibili per la mobilità pedonale?

    Directory of Open Access Journals (Sweden)

    Enrica Papa

    2008-12-01

    Full Text Available L’articolo propone un approfondimento su una particolare tipologia di sistemi per la mobilità pedonale: le reti pedonali dedicate. Questa tipologia di infrastrutture per la mobilità pedonale è caratterizzata da assi pedonali sotterranei (subway e sopraelevati (skyway che si strutturano come complesse strutture percorribili solo a piedi. Gli esempi emblematici sono la più ampia rete pedonale sotterranea del mondo di Montreal, che raggiunge un estensione di 32km ed è conosciuta come la ville intérieure e la rete sopraelevata di Calgary, che supera i 16km di passaggi pedonali di collegamento tra diversi edifici commerciali e terziari. Partendo da un’analisi comparativa di casi di studio, l’articolo descrive gli elementi caratteristici delle reti pedonali “non convenzionali”, mettendo in evidenza i punti di forza e di debolezza di questi esempi in cui il flusso pedonale è totalmente separato dagli spazi dedicati al traffico veicolare.

  16. An understanding of human dynamics in urban subway traffic from the Maximum Entropy Principle

    Science.gov (United States)

    Yong, Nuo; Ni, Shunjiang; Shen, Shifei; Ji, Xuewei

    2016-08-01

    We studied the distribution of entry time interval in Beijing subway traffic by analyzing the smart card transaction data, and then deduced the probability distribution function of entry time interval based on the Maximum Entropy Principle. Both theoretical derivation and data statistics indicated that the entry time interval obeys power-law distribution with an exponential cutoff. In addition, we pointed out the constraint conditions for the distribution form and discussed how the constraints affect the distribution function. It is speculated that for bursts and heavy tails in human dynamics, when the fitted power exponent is less than 1.0, it cannot be a pure power-law distribution, but with an exponential cutoff, which may be ignored in the previous studies.

  17. Accident information needs

    International Nuclear Information System (INIS)

    Hanson, D.J.; Arcieri, W.C.; Ward, L.W.

    1992-01-01

    A Five-step methodology has been developed to evaluate information needs for nuclear power plants under accident conditions and the availability of plant instrumentation during severe accidents. Step 1 examines the credible accidents and their relationships to plant safety functions. Step 2 determines the information personnel involved in accident management will need to understand plant behavior. Step 3 determines the capability of the instrumentation to function properly under severe accident conditions. Step 4 determines the conditions expected during the identified severe accidents. Step 5 compares the instrument capabilities and the severe accident conditions to evaluate the availability of the instrumentation to supply needed plant information

  18. Accident information needs

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, D.J.; Arcieri, W.C.; Ward, L.W.

    1992-12-31

    A Five-step methodology has been developed to evaluate information needs for nuclear power plants under accident conditions and the availability of plant instrumentation during severe accidents. Step 1 examines the credible accidents and their relationships to plant safety functions. Step 2 determines the information personnel involved in accident management will need to understand plant behavior. Step 3 determines the capability of the instrumentation to function properly under severe accident conditions. Step 4 determines the conditions expected during the identified severe accidents. Step 5 compares the instrument capabilities and the severe accident conditions to evaluate the availability of the instrumentation to supply needed plant information.

  19. Accident information needs

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, D.J.; Arcieri, W.C.; Ward, L.W.

    1992-01-01

    A Five-step methodology has been developed to evaluate information needs for nuclear power plants under accident conditions and the availability of plant instrumentation during severe accidents. Step 1 examines the credible accidents and their relationships to plant safety functions. Step 2 determines the information personnel involved in accident management will need to understand plant behavior. Step 3 determines the capability of the instrumentation to function properly under severe accident conditions. Step 4 determines the conditions expected during the identified severe accidents. Step 5 compares the instrument capabilities and the severe accident conditions to evaluate the availability of the instrumentation to supply needed plant information.

  20. Violence in Advertisements in New York City Subway Stations: A Pilot Study

    Science.gov (United States)

    Basch, Corey H.; Fullwood, M. D.; LeBlanc, Michael

    2017-01-01

    Violence has become a public health concern in the United States. Violent visually stimulating content encompasses various techniques such as fear, humor, shock, or violence, to stimulate a response or appeal toward awareness of human emotion. Exposing impressionable youth to violent advertisements can be particularly problematic. This is especially true in places like New York City where violent crime is a prevalent problem. With annual ridership reaching over 1.7 billion in 2014, the New York City subway system is abundant with advertisements. The purpose of this pilot study was to determine the frequency and type of violent advertising on the Lexington Avenue/East Side Line in New York City, running through the Bronx and Manhattan to represent the lower and higher median income earning boroughs. There were no statistically different findings in median household income at site of station by number of ads or source of violent. Destruction was the most common form of violence (n = 32, 42.7 %) followed by intent to strike (n = 18, 24 %), showing a weapon (n = 15, 20 %) and horror (n = 10, 13.3 %). Most ads (n = 46, 61.3 %) were found in stations heading uptown toward and through the Bronx, the borough where median household income is lowest, whereas 29 (38.7 %) were found in stations heading downtown. Future studies could focus on additional boroughs and subways lines, and could be collected at multiple points in time to determine of how prevalent violent advertising is throughout New York City and at different time frames. PMID:26518776

  1. Continuous Extraction of Subway Tunnel Cross Sections Based on Terrestrial Point Clouds

    Directory of Open Access Journals (Sweden)

    Zhizhong Kang

    2014-01-01

    Full Text Available An efficient method for the continuous extraction of subway tunnel cross sections using terrestrial point clouds is proposed. First, the continuous central axis of the tunnel is extracted using a 2D projection of the point cloud and curve fitting using the RANSAC (RANdom SAmple Consensus algorithm, and the axis is optimized using a global extraction strategy based on segment-wise fitting. The cross-sectional planes, which are orthogonal to the central axis, are then determined for every interval. The cross-sectional points are extracted by intersecting straight lines that rotate orthogonally around the central axis within the cross-sectional plane with the tunnel point cloud. An interpolation algorithm based on quadric parametric surface fitting, using the BaySAC (Bayesian SAmpling Consensus algorithm, is proposed to compute the cross-sectional point when it cannot be acquired directly from the tunnel points along the extraction direction of interest. Because the standard shape of the tunnel cross section is a circle, circle fitting is implemented using RANSAC to reduce the noise. The proposed approach is tested on terrestrial point clouds that cover a 150-m-long segment of a Shanghai subway tunnel, which were acquired using a LMS VZ-400 laser scanner. The results indicate that the proposed quadric parametric surface fitting using the optimized BaySAC achieves a higher overall fitting accuracy (0.9 mm than the accuracy (1.6 mm obtained by the plain RANSAC. The results also show that the proposed cross section extraction algorithm can achieve high accuracy (millimeter level, which was assessed by comparing the fitted radii with the designed radius of the cross section and comparing corresponding chord lengths in different cross sections and high efficiency (less than 3 s/section on average.

  2. Violence in Advertisements in New York City Subway Stations: A Pilot Study.

    Science.gov (United States)

    Basch, Corey H; Fullwood, M D; LeBlanc, Michael

    2016-04-01

    Violence has become a public health concern in the United States. Violent visually stimulating content encompasses various techniques such as fear, humor, shock, or violence, to stimulate a response or appeal toward awareness of human emotion. Exposing impressionable youth to violent advertisements can be particularly problematic. This is especially true in places like New York City where violent crime is a prevalent problem. With annual ridership reaching over 1.7 billion in 2014, the New York City subway system is abundant with advertisements. The purpose of this pilot study was to determine the frequency and type of violent advertising on the Lexington Avenue/East Side Line in New York City, running through the Bronx and Manhattan to represent the lower and higher median income earning boroughs. There were no statistically different findings in median household income at site of station by number of ads or source of violent. Destruction was the most common form of violence (n = 32, 42.7 %) followed by intent to strike (n = 18, 24 %), showing a weapon (n = 15, 20 %) and horror (n = 10, 13.3 %). Most ads (n = 46, 61.3 %) were found in stations heading uptown toward and through the Bronx, the borough where median household income is lowest, whereas 29 (38.7 %) were found in stations heading downtown. Future studies could focus on additional boroughs and subways lines, and could be collected at multiple points in time to determine of how prevalent violent advertising is throughout New York City and at different time frames.

  3. Fire deaths in aircraft without the crashworthy fuel system.

    Science.gov (United States)

    Springate, C S; McMeekin, R R; Ruehle, C J

    1989-10-01

    Cases reported to the Armed Forces Institute of Pathology were examined for occupants of helicopters without the crashworthy fuel system (CWFS) who survived crashes but died as a result of postcrash fires. There were 16 fire deaths in the 9 such accidents which occurred between January 1976 and April 1984. All of these victims would have survived if there had been no postcrash fire. Partial body destruction by fire probably prevented inclusion of many other cases. The dramatic reduction in fire deaths and injuries due to installation of the CWFS in Army helicopters is discussed. The author concludes that fire deaths and injuries in aircraft accidents could almost be eliminated by fitting current and future aircraft with the CWFS.

  4. Radiation doses in accidents at sea-transportation of spent fuel

    International Nuclear Information System (INIS)

    Appelgren, A.; Bergstroem, U.; Devell, L.

    1978-01-01

    In order to investigate the consequences of shipping accidents, a release of activity is assumed. This report presents the calculations of individual and collective doses from the two most severe postulated accidents which are given in a special accident analysis. One of the accidents is a ship collision together with fire on-board, the ship is floating after the collision and a certain quantity volatile fission products gives airborne activity. In the other case, it is a fire on-board, the ship will sink and cause a certain leakage to the sea

  5. Determinants of the property damage costs of tanker accidents

    International Nuclear Information System (INIS)

    Talley, W.K.

    1999-01-01

    This study investigates determinants of the vessel, oil cargo spillage, and other-property damage costs of tanker accidents. Tobit estimation of a three-equation recursive model suggests that, among types of tanker accidents, fire/explosion accidents incur the largest vessel damage costs, but the smallest oil cargo spillage costs. Alternatively, grounding accidents incur the smallest vessel damage costs, but the largest oil cargo spillage costs, reflecting the difficulty of controlling oil cargo spillage subsequent to such accidents. Also, oil cargo spillage costs are lower for US flag tanker accidents. A dollar of vessel damage cost increases other-property damage cost by 0.06 dollars, whereas a dollar of oil cargo spillage increases this cost by 1.55 dollars

  6. Causes of Coal Mine Accidents in the World and Turkey.

    Science.gov (United States)

    Küçük, Filiz Çağla Uyanusta; Ilgaz, Aslıhan

    2015-04-01

    Occupational accidents and occupational diseases are common in the mining sector in Turkey and throughout the world. The most common causes of accidents in coal mining are firedamp and dust explosions, landslips, mine fires, and technical failures related to transport and mechanization. An analysis of occupational accidents in the consideration of social and economic factors will let understand the real causes behind these accidents, which are said to happen inevitably due to technical deficiencies or failures. Irregular working conditions, based on profit maximization and cost minimization, are related to strategic operational preferences and public policies. Proving that accidents in mines, where occupational health and safety measures are not implemented and inspections are not done properly or at all, are caused by the fact that production is imposed to be carried out in the fastest, cheapest, and most profitable way will allow us to take steps to prevent further mine accidents.

  7. Causes of Coal Mine Accidents in the World and Turkey

    Science.gov (United States)

    Küçük, Filiz Çağla Uyanusta; Ilgaz, Aslıhan

    2015-01-01

    Occupational accidents and occupational diseases are common in the mining sector in Turkey and throughout the world. The most common causes of accidents in coal mining are firedamp and dust explosions, landslips, mine fires, and technical failures related to transport and mechanization. An analysis of occupational accidents in the consideration of social and economic factors will let understand the real causes behind these accidents, which are said to happen inevitably due to technical deficiencies or failures. Irregular working conditions, based on profit maximization and cost minimization, are related to strategic operational preferences and public policies. Proving that accidents in mines, where occupational health and safety measures are not implemented and inspections are not done properly or at all, are caused by the fact that production is imposed to be carried out in the fastest, cheapest, and most profitable way will allow us to take steps to prevent further mine accidents. PMID:29404108

  8. Severe accident phenomena

    International Nuclear Information System (INIS)

    Jokiniemi, J.; Kilpi, K.; Lindholm, I.; Maekynen, J.; Pekkarinen, E.; Sairanen, R.; Silde, A.

    1995-02-01

    Severe accidents are nuclear reactor accidents in which the reactor core is substantially damaged. The report describes severe reactor accident phenomena and their significance for the safety of nuclear power plants. A comprehensive set of phenomena ranging from accident initiation to containment behaviour and containment integrity questions are covered. The report is based on expertise gained in the severe accident assessment projects conducted at the Technical Research Centre of Finland (VTT). (49 refs., 32 figs., 12 tabs.)

  9. Fire safety in atomic power plants

    International Nuclear Information System (INIS)

    Kench, R.L.; British Insurance

    1988-01-01

    The main reactor types are described briefly - Magnox, advanced gas cooled, pressurized water and fast reactors. Fire risks exist at fuel stores and spent fuel storage facilities. Simple fire prevention measures are suggested. Solid radioactive wastes can also be combustible. Various fire prevention measures for the different storage methods, eg compaction, are given. Gaseous and liquid wastes are also considered. The main types of reactor accident are described and the causes of four incidents - at Chernobyl, Windscale, Brownsferry and Three Mile Island, are examined. (U.K.)

  10. The impact of safety design consideration on future LMFBR developments. (R and D needs related to accident accommodation)

    International Nuclear Information System (INIS)

    Justin, F.

    1985-04-01

    Accident accommodation for design accidents or even beyond design basis accidents is based on components and systems for which important research and development work is needed. Main issues are treated: fuel failure faults, sodium fires, decay heat removal, accommodation of energetics and debris

  11. Learning lessons from Natech accidents - the eNATECH accident database

    Science.gov (United States)

    Krausmann, Elisabeth; Girgin, Serkan

    2016-04-01

    When natural hazards impact industrial facilities that house or process hazardous materials, fires, explosions and toxic releases can occur. This type of accident is commonly referred to as Natech accident. In order to prevent the recurrence of accidents or to better mitigate their consequences, lessons-learned type studies using available accident data are usually carried out. Through post-accident analysis, conclusions can be drawn on the most common damage and failure modes and hazmat release paths, particularly vulnerable storage and process equipment, and the hazardous materials most commonly involved in these types of accidents. These analyses also lend themselves to identifying technical and organisational risk-reduction measures that require improvement or are missing. Industrial accident databases are commonly used for retrieving sets of Natech accident case histories for further analysis. These databases contain accident data from the open literature, government authorities or in-company sources. The quality of reported information is not uniform and exhibits different levels of detail and accuracy. This is due to the difficulty of finding qualified information sources, especially in situations where accident reporting by the industry or by authorities is not compulsory, e.g. when spill quantities are below the reporting threshold. Data collection has then to rely on voluntary record keeping often by non-experts. The level of detail is particularly non-uniform for Natech accident data depending on whether the consequences of the Natech event were major or minor, and whether comprehensive information was available for reporting. In addition to the reporting bias towards high-consequence events, industrial accident databases frequently lack information on the severity of the triggering natural hazard, as well as on failure modes that led to the hazmat release. This makes it difficult to reconstruct the dynamics of the accident and renders the development of

  12. Transportation accident response of a high-capacity truck cask for spent fuel

    International Nuclear Information System (INIS)

    O'Connell, W.J.; Glaser, R.E.; Johnson, G.L.; Perfect, S.A.; McGuinn, E.J.; Lake, W.H.

    1995-11-01

    Two of the primary goals of this study were (i) to check the structural and thermal performance of the GA-4 cask in a broad range of accidents and (ii) to carry out a severe-accidents analysis as had been addressed in the Modal Study but now using a specific recent cask design and using current-generation computer models and capabilities. At the same time, it was desired to compare the accident performance of the Ga-4 cask to that of the generic truck cask analyzed in the Modal Study. The same range of impact and fire accidents developed in the Modal Study was adopted for this study. The accident-description data base of the Modal Study categorizes accidents into types of collisions with mobile or fixed objects, non-collision accidents, and fires. The mechanical modes of damage may be via crushing, impact, or puncture. The fire occurrences in the Modal Study data are based on truck accident statistics. The fire types are taken to be pool fires of petroleum products from fuel tanks and/or cargoes

  13. UK position paper on sodium fires

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, G J [National Nuclear Corporation Ltd., Risley, Warrington, Cheshire (United Kingdom); Glass, D [United Kingdom Atomic Energy Authority, Dounreay Nuclear Power Development Establishment, Thurso, Caithness (United Kingdom); Newman, R N [Central Electricity Generating Board, Berekely Nuclear Laboratory, Berkeley, Gloucestershire (United Kingdom); Ramsdale, S A [United Kingdom Atomic Energy Authority, Safety and Reliability Directorate, Culcheth, Cheshire (United Kingdom); Snelling, K W [United Kingdom Atomic Energy Authority, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1989-07-01

    The UK has over several years developed a philosophy for the prevention, mitigation and extinguishment of sodium fires. The systems which were developed for PFR have been continuously revised and modified and from these considerations systems were proposed for CDFR. The latest phases of this development are described with reference to the CDFR plant. The current analytical and experimental work on fires, aerosols and sodium concrete reactions is also discussed. The UK are developing codes to analyse the effects of a sodium fire in a building and to model aerosol behaviour following a fire. Experimental work on small scale fires, aerosol behaviour, filtration devices and sodium concrete reaction is being carried out on a laboratory scale. Techniques for aerosol measurement and characterisation have also been developed and used both In the laboratory and large scale tests. Larger scale tests of sodium fire extinguishment techniques have also been performed. Currently a programme of tests (SOFA) of large scale fires in the open to investigate the chemical and physical changes in the aerosol and its dispersion in the atmosphere are just beginning. The UK studies are intended to both assist in the development of prevention and mitigation systems for design base and beyond design base accidents in any building which contains sodium (or sodium potassium alloy) and also to provide methods for assessing the risks from such accidents. (author)

  14. UK position paper on sodium fires

    International Nuclear Information System (INIS)

    Vaughan, G.J.; Glass, D.; Newman, R.N.; Ramsdale, S.A.; Snelling, K.W.

    1989-01-01

    The UK has over several years developed a philosophy for the prevention, mitigation and extinguishment of sodium fires. The systems which were developed for PFR have been continuously revised and modified and from these considerations systems were proposed for CDFR. The latest phases of this development are described with reference to the CDFR plant. The current analytical and experimental work on fires, aerosols and sodium concrete reactions is also discussed. The UK are developing codes to analyse the effects of a sodium fire in a building and to model aerosol behaviour following a fire. Experimental work on small scale fires, aerosol behaviour, filtration devices and sodium concrete reaction is being carried out on a laboratory scale. Techniques for aerosol measurement and characterisation have also been developed and used both In the laboratory and large scale tests. Larger scale tests of sodium fire extinguishment techniques have also been performed. Currently a programme of tests (SOFA) of large scale fires in the open to investigate the chemical and physical changes in the aerosol and its dispersion in the atmosphere are just beginning. The UK studies are intended to both assist in the development of prevention and mitigation systems for design base and beyond design base accidents in any building which contains sodium (or sodium potassium alloy) and also to provide methods for assessing the risks from such accidents. (author)

  15. Discovery Mondays - Men of fire: the fire brigade show their mettle

    CERN Multimedia

    2004-01-01

    Flashover and backdraught, these technical terms refer to two of the most dangerous phenomena associated with fires. In order to train in dealing with them, in the course of their fire fighting duties the CERN fire brigade use special simulation equipment. The demonstrations are rather spectacular... Thrills are therefore guaranteed at the next Discovery Monday on 2 February! In the course of the evening, you will see fire-fighters demonstrate climbing techniques including abseiling, a method they would have to use to access underground structures on the CERN site in the event of an accident. The accomplished climbers (the Hazardous Environments Response Team) will provide detailed explanations of the rescue techniques and procedures they use in tunnels and hazardous environments. However, the remit of the CERN fire brigade goes well beyond fire-fighting. It ranges from monitoring confined spaces to dealing with flooding and preventing chemical hazards. A wide range of equipment enables them to fulfil thei...

  16. Research of Emergency Smoke Exhausting in Running Subway Train%运行地铁列车应急排烟模式的研究

    Institute of Scientific and Technical Information of China (English)

    詹文元

    2012-01-01

    Taking head circumference of infants as the higher limit, numerical models of subway train getting fire in tunnel were established based on gas dynamics and combustion theory with the software FLUENT. Smoking-exhausting required time and pressure inside and outside of the train with different speed and opening door scheme was simulated, which showed that the smoke inside the railway carriage could be rapidly exhausted when the door opening degree was 0.07 m and the speed was 30 km/h. Experiment result in the Window of the world and the chiwan 2 Line of Shenzhen metro was consistent with numerical approach, which indicated numerical analysis for emergency smoke-exhausting mode was reliable with high accuracy.%通过初生婴儿的头围确定车门开度的上限值,利用气体动力学与燃烧学理论建立了地铁列车在隧道发生火灾时的数值分析模型,采用FLUENT软件模拟了地铁列车在不同速度、不同开门方案下,排烟所需时间及车厢内外压强分布.结果表明,列车车门开度0.07m、车速为30 km/h时,能够快速、有效地排出烟雾.在深圳地铁“世界之窗-赤湾”2号线对数值分析结果进行了试验验证.试验结果与数值分析结果吻合,表明该应急排烟模式的数值分析方法具有较高精度.

  17. A case study of electrostatic accidents in the process of oil-gas storage and transportation

    International Nuclear Information System (INIS)

    Hu, Yuqin; Liu, Jinyu; Gao, Jianshen; Wang, Diansheng

    2013-01-01

    Ninety nine electrostatic accidents were reviewed, based on information collected from published literature. All the accidents over the last 30 years occurred during the process of oil-gas storage and transportation. Statistical analysis of these accidents was performed based on the type of complex conditions where accidents occurred, type of tanks and contents, and type of accidents. It is shown that about 85% of the accidents occurred in tank farms, gas stations or petroleum refineries, and 96% of the accidents included fire or explosion. The fishbone diagram was used to summarize the effects and the causes of the effects. The results show that three major reasons were responsible for accidents, including improper operation during loading and unloading oil, poor grounding and static electricity on human bodies, which accounted for 29%, 24% and 13% of the accidents, respectively. Safety actions are suggested to help operating engineers to handle similar situations in the future.

  18. The dominance of accidents caused by banalities

    DEFF Research Database (Denmark)

    Jørgensen, Kirsten

    Most prevention analysis is focused on high risks, such as explosion, fire, lack of containment for chemicals, crashes in transportation systems, lack of oxygen, or chemical poisoning. In the industrial world, these kinds of risk still lead to incidents with huge consequences, albeit very seldom...... as an example of how much information such systems can offer in general for the work of accident prevention in more traditional and common enterprises....

  19. Spent fuel shipping cask accident evaluation

    International Nuclear Information System (INIS)

    Fields, S.R.

    1975-12-01

    Mathematical models have been developed to simulate the dynamic behavior, following a hypothetical accident and fire, of typical casks designed for the rail shipment of spent fuel from nuclear reactors, and to determine the extent of radioactive releases under postulated conditions. The casks modeled were the IF-300, designed by the General Electric Company for the shipment of spent LWR fuel, and a cask designed by the Aerojet Manufacturing Company for the shipment of spent LMFBR fuel

  20. Fire protection system operating experience review for fusion applications

    International Nuclear Information System (INIS)

    Cadwallader, L.C.

    1995-12-01

    This report presents a review of fire protection system operating experiences from particle accelerator, fusion experiment, and other applications. Safety relevant operating experiences and accident information are discussed. Quantitative order-of-magnitude estimates of fire protection system component failure rates and fire accident initiating event frequencies are presented for use in risk assessment, reliability, and availability studies. Safety concerns with these systems are discussed, including spurious operation. This information should be useful to fusion system designers and safety analysts, such as the team working on the Engineering Design Activities for the International Thermonuclear Experimental Reactor

  1. Fire protection system operating experience review for fusion applications

    Energy Technology Data Exchange (ETDEWEB)

    Cadwallader, L.C.

    1995-12-01

    This report presents a review of fire protection system operating experiences from particle accelerator, fusion experiment, and other applications. Safety relevant operating experiences and accident information are discussed. Quantitative order-of-magnitude estimates of fire protection system component failure rates and fire accident initiating event frequencies are presented for use in risk assessment, reliability, and availability studies. Safety concerns with these systems are discussed, including spurious operation. This information should be useful to fusion system designers and safety analysts, such as the team working on the Engineering Design Activities for the International Thermonuclear Experimental Reactor.

  2. Sodium fires and nuclear power station safety

    International Nuclear Information System (INIS)

    Ivanenko, V.N.; Zubin, A.; Drobyshev, A.V.

    1986-01-01

    The danger of sodium aerosol release at a design basis accident (DBA) of a sodium-cooled fast reactor that involves coolant leakage and burning, is being analyzed. It has been shown that radioactive and toxic releases at DBA do not exceed permissible values. Some means of sodium fire fighting are described. (author)

  3. Radiological accidents, scenarios, planning and answers

    International Nuclear Information System (INIS)

    Solis Delgado, Alexander.

    2008-01-01

    Radiological accidents, scenarios and the importance of a good planning to prevent and control these types of accidents are presented. The radiation can be only one of the risks in an accident, most of dominant radiological risks are not radiological (fire, toxic gases, etc.). The common causes of radiological accidents, potential risks such as external irradiation, internal contamination and the environment pollution are highlighted. In addition, why accidents happen and how they evolve is explained. It describes some incidents with the radiation occurred in Costa Rica from 1993 to 2007. The coordination of emergency management in Costa Rica in relation to a radiological accident, and some mechanisms of action that have practiced in other places are focuses. Among the final considerations are the need to finalize the national plan for radiological emergencies as a tool of empowerment for the teams of emergency care and the availability of information. Likewise the processes of communication, coordination and cooperation to avoid chaos, confusion and crisis are also highlighted [es

  4. Design and evaluation of a suspension seat to reduce vibration exposure of subway operators: a case study.

    Science.gov (United States)

    Marcotte, Pierre; Beaugrand, Sylvie; Boutin, Jérôme; Larue, Christian

    2010-01-01

    Subway operators have complained about discomfort caused by whole-body vibration. To address this problem, a suspension seat with extensive ergonomic features has been adapted to the confined space of the subway operator cab. The suspension was modified from an existing suspension in order to reduce the dominant frequency of the subway vertical vibration (2.4 Hz). The suspension seat has been extensively tested on a vertical hydraulic shaker. These tests have shown that the SEAT value was lower for a higher vibration level, for higher subject weight, and for the suspension adjusted at median height. The seat also produces a lower SEAT value when there was a predominance of the 6 Hz vibration component. The horizontal seat adjustments had no influence on the suspension SEAT value. Removing the suspension damper also decreases the SEAT value for all the tested configurations. The final version of the suspension seat prototype was validated during normal subway operation with 19 different operators having weight in the 5th, 50th and 95th percentile of the operator population. Accelerations were measured with triaxial accelerometers at the seat cushion, above the suspension and on the floor. In addition to the vibration measurements, each operator was asked about his perceived discomfort from vibration exposure. Globally, the suspension seat attenuated the vertical vibration (SEAT values from 0.86 to 0.99), but discomfort due to amplification of the 2.4 Hz component occurred when the suspension height was adjusted at the minimum, even when the global weighted acceleration was lower (SEAT value < 1). These results suggest that in order to reduce the discomfort caused by whole-body vibration, the transmissibility of the seat should also be considered, in particular when there is a dominant frequency in the vibration spectra.

  5. Learning fire-fighting lessons after Chernobyl

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Fire protection measures in Soviet nuclear power plants were set out in November 1987, in the Nuclear Power Plant Design Fire Protection Standards (VSN 01-87, USSR Ministry of Atomic Energy). The most important of these measures are. Avoiding as far as possible the use of combustible materials in plant structures and equipment. Dividing buildings and areas into suitable fire-fighting zones. Ensuring reliable fire protection of the control and safety systems. Protecting technical personnel from the dangers of a fire while they are performing essential accident-repair work and facilitating evacuation procedures (providing at least two evacuation routes and exits, anti-smoke protection of evacuation routes and control panel areas etc). Installing automatic fire-extinguishing and fire alarm systems. Providing various stationary facilities and equipment to assist the use of mobile fire-fighting appliances. In addition, a special fire-fighting division is being set up in every nuclear power plant while the first unit is still being constructed. These divisions work in close co-operation with the technical personnel management of the plant and with the bodies responsible for monitoring nuclear safety. (author)

  6. Accident risk associated with smartphone addiction: A study on university students in Korea.

    Science.gov (United States)

    Kim, Hye-Jin; Min, Jin-Young; Kim, Hyun-Jin; Min, Kyoung-Bok

    2017-12-01

    Background and aims The smartphone is one of the most popular devices, with the average smartphone usage at 162 min/day and the average length of phone usage at 15.79 hr/week. Although significant concerns have been made about the health effects of smartphone addiction, the relationship between smartphone addiction and accidents has rarely been studied. We examined the association between smartphone addiction and accidents among South Korean university students. Methods A total of 608 college students completed an online survey that included their experience of accidents (total number; traffic accidents; falls/slips; bumps/collisions; being trapped in the subway, impalement, cuts, and exit wounds; and burns or electric shocks), their use of smartphone, the type of smartphone content they most frequently used, and other variables of interests. Smartphone addiction was estimated using Smartphone Addiction Proneness Scale, a standardized measure developed by the National Institution in Korea. Results Compared with normal users, participants who were addicted to smartphones were more likely to have experienced any accidents (OR = 1.90, 95% CI: 1.26-2.86), falling from height/slipping (OR = 2.08, 95% CI: 1.10-3.91), and bumps/collisions (OR = 1.83, 95% CI: 1.16-2.87). The proportion of participants who used their smartphones mainly for entertainment was significantly high in both the accident (38.76%) and smartphone addiction (36.40%) groups. Discussion and conclusions We suggest that smartphone addiction was significantly associated with total accident, falling/slipping, and bumps/collisions. This finding highlighted the need for increased awareness of the risk of accidents with smartphone addiction.

  7. Nuclear accident dosimetry

    International Nuclear Information System (INIS)

    1982-01-01

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  8. Nuclear accident dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-12-31

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  9. Statistical analysis of accident data associated with sea transport (data from 1994-1997). Annex 1

    International Nuclear Information System (INIS)

    Schneider, T.; Tabarre, M.; Armingaud, F.

    2001-01-01

    This analysis is based on Lloyd's database concerning sea transport accidents for the 1994-1997 period and completes the previous analysis based on 1994 data. It gives an accurate description of the world fleet and the most severe ship accidents (total losses), as well as the frequencies of accident (in average on the 1994-1997 period the frequency of accident for cargo carrying ships is 2.57.10 -3 loss /ship.year). Furthermore, an analysis has been performed on the ship casualties recorded by the Marine Accident Investigation Branch (MAIB) for UK vessels for the 1990-1996 period, this database including all accidents for which a declaration has been made to authorities (for example, the average frequency of fires derived from this analysis is 1.36.10 -2 per ship.year, this occurrence corresponding to the occurrence of initiating events of fire). Concerning fire accidents aboard ships supposed to be representative of the radioactive material transporters, a specific analysis was achieved by the French Bureau Veritas, on a selection of the world casualties (total losses) for the 1978-1988 period. This analysis related to the origin of the fire points out that it originates mainly in the machinery room and quarters. In a few cases the fire duration recorded is more than one day. (author)

  10. Active Fire Mapping Program

    Science.gov (United States)

    Active Fire Mapping Program Current Large Incidents (Home) New Large Incidents Fire Detection Maps MODIS Satellite Imagery VIIRS Satellite Imagery Fire Detection GIS Data Fire Data in Google Earth ...

  11. Fire Safety (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Fire Safety KidsHealth / For Parents / Fire Safety What's in ... event of a fire emergency in your home. Fire Prevention Of course, the best way to practice ...

  12. Fire Research Enclosure

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Simulates submarine fires, enclosed aircraft fires, and fires in enclosures at shore facilities .DESCRIPTION: FIRE I is a pressurizable, 324 cu m(11,400 cu...

  13. Management of Radioactive Waste after a Nuclear Power Plant Accident

    International Nuclear Information System (INIS)

    Strand, Per; Laurent, Gerard; Rindo, Hiroshi; Georges, Christine; Ito, Eiichiro; Yamada, Norikazu; Iablokov, Iuri; Kilochytska, Tatiana; Jefferies, Nick; Byrne, Jim; Siemann, Michael; Koganeya, Toshiyuki; Aoki, Hiroomi

    2016-01-01

    The NEA Expert Group on Fukushima Waste Management and Decommissioning R and D (EGFWMD) was established in 2014 to offer advice to the authorities in Japan on the management of large quantities of on-site waste with complex properties and to share experiences with the international community and NEA member countries on ongoing work at the Fukushima Daiichi site. The group was formed with specialists from around the world who had gained experience in waste management, radiological contamination or decommissioning and waste management R and D after the Three Mile Island and Chernobyl accidents. This report provides technical opinions and ideas from these experts on post-accident waste management and R and D at the Fukushima Daiichi site, as well as information on decommissioning challenges. Chapter 1 provides general descriptions and a short introduction to nuclear accidents or radiological contaminations; for instance the Chernobyl NPP accident, the Three Mile Island Unit 2 accident and the Windscale fire accident. Chapter 2 provides experiences on regulator-implementer interaction in both normal and abnormal situations, including after a nuclear accident. Chapter 3 provides experiences on stakeholder involvement after accidents. These two chapters focus on human aspects after an accident and provide recommendations on how to improve communication between stakeholders so as to resolve issues arising after unexpected nuclear accidents. Chapters 4, 5 and 6 provide information on technical issues related to waste management after accidents. Chapter 4 focuses on the physical and chemical nature of the waste, Chapter 5 on radiological characterisation, and Chapter 6 on waste classification and categorisation. The persons involved in waste management after an accident should address these issues as soon as possible after the accident. Chapters 7 and 8 also focus on technical issues but with a long-term perspective of the waste direction in the future. Chapter 7 relates

  14. Human Factors in Fire Safety Management and Prevention

    Directory of Open Access Journals (Sweden)

    M.A. Othuman Mydin

    2014-07-01

    Full Text Available Fire protection is the study and practice of mitigating the unwanted effects of potentially destructive fires. It involves the study of the behavior, compartmentalization, and investigation of fire and its related emergencies, as well as the research and development, production, testing and application of mitigating systems. Problems still occurred despite of the adequate fire safety systems installed. For most people in high-risk buildings, not all accidents were caused by them. They were more likely to be the victims of a fire that occurred. Besides damaging their properties and belongings, some people were burned to death for not knowing what to do if fire happens in their place. This paper will present the human factors in fire safety management and prevention system.

  15. Plutonium accident resistant container project

    International Nuclear Information System (INIS)

    Andersen, J.A.

    1978-09-01

    The PARC (plutonium accident resistant container) project resulted in the design, development, and certification testing of a crashworthy air-transportable plutonium package (shipping container) for certification by the USNRC (Nuclear Regulatory Commission). This PAT-1 (plutonium air transportable) package survives a very severe sequential test program of impact, crush, puncture, slash, burn, and water immersion. There is also an individual hydrostatic pressure test. The package has a payload mass capacity of 2 kg of PuO 2 and a thermal capacity of 25 watts. The design rationale for very high energy absorption (impact, crush, puncture, and slash protection) with residual high-level fire protection, resulted in a reasonably small air-transportable package, advancing the packaging state-of-art. Optimization design iterations were utilized in the areas of impact energy absorption and stress and thermal analysis. Package test results are presented in relation to radioactive materials containment acceptance criteria, shielding and criticality standards

  16. Plutonium accident resistant container project

    International Nuclear Information System (INIS)

    Andersen, J.A.

    1978-05-01

    The PARC (plutonium accident resistant container) project resulted in the design, development, and certification testing of a crashworthy air-transportable plutonium package (shipping container) for certification by the USNRC. This PAT-1 (plutonium air transportable) package survives a very severe sequential test program of impact, crush, puncture, slash, burn, and water immersion. There is also an individual hydrostatic pressure test. The package has a payload mass capacity of 2 kg of PuO2 and a thermal capacity of 25 watts. The design rationale for very high energy absorption (impact, crush, puncture, and slash protection) with residual high-level fire protection, resulted in a reasonalby small air-transportable package, advancing the packaging state-of-art. Optimization design iterations were utilized in the areas of impact energy absorption and stress and thermal analysis. Package test results are presented in relation to radioactive materials containment acceptance criteria, shielding and criticality standards

  17. Supervisor's accident investigation handbook

    International Nuclear Information System (INIS)

    1980-02-01

    This pamphlet was prepared by the Environmental Health and Safety Department (EH and S) of Lawrence Berkeley Laboratory (LBL) to provide LBL supervisors with a handy reference to LBL's accident investigation program. The publication supplements the Accident and Emergencies section of LBL's Regulations and Procedures Manual, Pub. 201. The present guide discusses only accidents that are to be investigated by the supervisor. These accidents are classified as Type C by the Department of Energy (DOE) and include most occupational injuries and illnesses, government motor-vehicle accidents, and property damages of less than $50,000

  18. Trend of elevator-related accidents in tehran.

    Science.gov (United States)

    Khaji, Ali; Ghodsi, Syyed Mohammad

    2014-06-01

    Elevator-related accidents are uncommon, but can cause significant injury. However, little data exist on these types of accidents. To compile and analyze accident data involving elevators in an effort to eliminate or at least significantly reduce such accidents. In this retrospective study we investigated 1,819 cases of elevator-related accidents during a four-year period (1999-2003) in Tehran. The data were obtained from the Tehran Safety Services & Fire Fighting Organization (TSFO) that is officially and solely responsible to conduct rescue missions of civilians in Tehran. The number of elevator accidents has increased steadily during the four year study period. During these four years there was a positive upward trend for serious injuries and mortality resulting from elevator accidents. Technical problems were the main cause with 74.5%, followed by power loss and overcapacity riding with 11.5% and 7.9% respectively. Sixty-three individuals sustained serious injury and 15 people died as a result of elevator accidents. The number of accidents was significantly higher in summer (x2=18.32, P=0.032) and a considerable proportion of incidences (54%, 947 cases out of 1819) occurred between 5 and 12 pm. Establishment of an organization to inspect the settings, maintenance, and repair of elevators is necessary.

  19. Trend of Elevator-Related Accidents in Tehran

    Directory of Open Access Journals (Sweden)

    Ali Khaji

    2014-06-01

    Full Text Available Background:   Elevator-related accidents are uncommon, but can cause significant injury. However, little data exist on these types of accidents. To compile and analyze accident data involving elevators in an effort to eliminate or at least significantly reduce such accidents. Methods: In this retrospective study we investigated 1,819 cases of elevator-related accidents during a four-year period (1999-2003 in Tehran. The data were obtained from the Tehran Safety Services & Fire Fighting Organization (TSFO that is officially and solely responsible to conduct rescue missions of civilians in Tehran. Results: The number of elevator accidents has increased steadily during the four year study period. During these four years here was a positive upward trend for serious injuries and mortality resulting from elevator accidents. Technical problems were the main cause with 74.5%, followed by power loss and overcapacity riding with 11.5% and 7.9%respectively. Sixty-three individuals sustained serious injury and 15 people died as a result of elevator accidents. The number of accidents was significantly higher in summer (x2=18.32, P=0.032 and a considerable proportion of incidences (54%, 947 cases out of 1819 occurred between 5 and 12 pm. Conclusions: Establishment of an organization to inspect the settings, maintenance, and repair of elevators is necessary

  20. The Angra 1 fire PRA project

    International Nuclear Information System (INIS)

    Silva, Luiz E. Massiere de C.; Kassawara, Robert

    2009-01-01

    The Angra 1 Fire PRA (Probabilistic Risk Assessment) is under development by ELETRONUCLEAR jointly with EPRI (Electric Power Research Institute). The project was started January of 2007 and it is foreseen to be finished in the middle of the next year. The study is being conducted according to the newest methodology developed by EPRI and NRC/RES (U.S. Nuclear Regulatory Commission - Office of Regulatory Research) published in 2005 as Fire PRA Methodology for Nuclear Power Facilities (NUREG/CR-6850 or EPRI TR-1011989) [1]. Starting from the Internal Events Angra 1 PRA model Level 1 the project aims to be a comprehensive plant-specific fire analysis to identify the possible consequences of a fire in the plant vital areas which threaten the integrity of systems relevant to the safety, challenging the safety functions and representing a risk of accident that can lead to a core damage. The main tasks include the plant boundary and partitioning, the fire PRA component selection and the identification of the possible fire scenarios (ignition, propagation, detection, extinction and hazards) considering human failure events to establish the fire-induced risk model for quantification of the risk for nuclear core damage taking into account the plant design and its fire protection resources. This work presents a general discussion on the methodology applied to the completed steps of the project. (author)

  1. Subway platform air quality: Assessing the influences of tunnel ventilation, train piston effect and station design

    Science.gov (United States)

    Moreno, T.; Pérez, N.; Reche, C.; Martins, V.; de Miguel, E.; Capdevila, M.; Centelles, S.; Minguillón, M. C.; Amato, F.; Alastuey, A.; Querol, X.; Gibbons, W.

    2014-08-01

    A high resolution air quality monitoring campaign (PM, CO2 and CO) was conducted on differently designed station platforms in the Barcelona subway system under: (a) normal forced tunnel ventilation, and (b) with daytime tunnel ventilation systems shut down. PM concentrations are highly variable (6-128 μgPM1 m-3, 16-314 μgPM3 m-3, and 33-332 μgPM10 m-3, 15-min averages) depending on ventilation conditions and station design. Narrow platforms served by single-track tunnels are heavily dependent on forced tunnel ventilation and cannot rely on the train piston effect alone to reduce platform PM concentrations. In contrast PM levels in stations with spacious double-track tunnels are not greatly affected when tunnel ventilation is switched off, offering the possibility of significant energy savings without damaging air quality. Sampling at different positions along the platform reveals considerable lateral variation, with the greatest accumulation of particulates occurring at one end of the platform. Passenger accesses can dilute PM concentrations by introducing cleaner outside air, although lateral down-platform accesses are less effective than those positioned at the train entry point. CO concentrations on the platform are very low (≤1 ppm) and probably controlled by ingress of traffic-contaminated street-level air. CO2 averages range from 371 to 569 ppm, changing during the build-up and exchange of passengers with each passing train.

  2. NeuroLines: A Subway Map Metaphor for Visualizing Nanoscale Neuronal Connectivity

    KAUST Repository

    Al-Awami, Ali K.

    2014-12-31

    We present NeuroLines, a novel visualization technique designed for scalable detailed analysis of neuronal connectivity at the nanoscale level. The topology of 3D brain tissue data is abstracted into a multi-scale, relative distance-preserving subway map visualization that allows domain scientists to conduct an interactive analysis of neurons and their connectivity. Nanoscale connectomics aims at reverse-engineering the wiring of the brain. Reconstructing and analyzing the detailed connectivity of neurons and neurites (axons, dendrites) will be crucial for understanding the brain and its development and diseases. However, the enormous scale and complexity of nanoscale neuronal connectivity pose big challenges to existing visualization techniques in terms of scalability. NeuroLines offers a scalable visualization framework that can interactively render thousands of neurites, and that supports the detailed analysis of neuronal structures and their connectivity. We describe and analyze the design of NeuroLines based on two real-world use-cases of our collaborators in developmental neuroscience, and investigate its scalability to large-scale neuronal connectivity data.

  3. NeuroLines: A Subway Map Metaphor for Visualizing Nanoscale Neuronal Connectivity

    KAUST Repository

    Al-Awami, Ali K.; Beyer, Johanna; Strobelt, Hendrik; Kasthuri, Narayanan; Lichtman, Jeff W.; Pfister, Hanspeter; Hadwiger, Markus

    2014-01-01

    We present NeuroLines, a novel visualization technique designed for scalable detailed analysis of neuronal connectivity at the nanoscale level. The topology of 3D brain tissue data is abstracted into a multi-scale, relative distance-preserving subway map visualization that allows domain scientists to conduct an interactive analysis of neurons and their connectivity. Nanoscale connectomics aims at reverse-engineering the wiring of the brain. Reconstructing and analyzing the detailed connectivity of neurons and neurites (axons, dendrites) will be crucial for understanding the brain and its development and diseases. However, the enormous scale and complexity of nanoscale neuronal connectivity pose big challenges to existing visualization techniques in terms of scalability. NeuroLines offers a scalable visualization framework that can interactively render thousands of neurites, and that supports the detailed analysis of neuronal structures and their connectivity. We describe and analyze the design of NeuroLines based on two real-world use-cases of our collaborators in developmental neuroscience, and investigate its scalability to large-scale neuronal connectivity data.

  4. Indoor radon distribution of subway stations in a Korean major city

    International Nuclear Information System (INIS)

    Yoon, Seokwon; Chang, Byung-Uck; Kim, Yongjae; Byun, Jong-In; Yun, Ju-Yong

    2010-01-01

    The overall survey on indoor radon concentration was conducted at all subway stations in a major city, Daejeon in the central part of Korea. It was quarterly performed from September 2007 to August 2008. The annual arithmetic mean of indoor radon concentration of all the stations was 34.1 ± 14.7 Bq m -3 , and the range of values was from 9.4 to 98.2 Bq m -3 . The radon concentrations in groundwater (average 31.0 ± 0.8 Bq m -3 ) were not significantly high in most stations, but the concentration (177.9 ± 2.3 Bq L -1 ) of one station was over the level of 148 Bq L -1 in drinking water proposed by U.S. EPA. Based on indoor survey results, the approximate average of the annual effective dose by radon inhalation to the employees and passengers were 0.24 mSv y -1 , and 0.02 mSv y -1 , respectively. Although the effective dose based on the UNSCEAR report was potentially estimated, for more accurate assessment, the additional survey on the influence by indoor radon will be necessary.

  5. Model uncertainty of various settlement estimation methods in shallow tunnels excavation; case study: Qom subway tunnel

    Science.gov (United States)

    Khademian, Amir; Abdollahipour, Hamed; Bagherpour, Raheb; Faramarzi, Lohrasb

    2017-10-01

    In addition to the numerous planning and executive challenges, underground excavation in urban areas is always followed by certain destructive effects especially on the ground surface; ground settlement is the most important of these effects for which estimation there exist different empirical, analytical and numerical methods. Since geotechnical models are associated with considerable model uncertainty, this study characterized the model uncertainty of settlement estimation models through a systematic comparison between model predictions and past performance data derived from instrumentation. To do so, the amount of surface settlement induced by excavation of the Qom subway tunnel was estimated via empirical (Peck), analytical (Loganathan and Poulos) and numerical (FDM) methods; the resulting maximum settlement value of each model were 1.86, 2.02 and 1.52 cm, respectively. The comparison of these predicted amounts with the actual data from instrumentation was employed to specify the uncertainty of each model. The numerical model outcomes, with a relative error of 3.8%, best matched the reality and the analytical method, with a relative error of 27.8%, yielded the highest level of model uncertainty.

  6. Uncovering stable and occasional human mobility patterns: A case study of the Beijing subway

    Science.gov (United States)

    Yong, Nuo; Ni, Shunjiang; Shen, Shifei; Chen, Peng; Ji, Xuewei

    2018-02-01

    There have generally been two kinds of approaches to the empirical study of human mobility. At the group level, some valuable information might be submerged in statistical noise, while due to the diversity of individual purpose and preference, there is still no general statistical regularity of human mobility at the individual level. In this paper, we considered group-level human mobility as the combination of several basic patterns and analyzed the collective mobility by category. Utilizing matrix factorization and correlation analysis, we extracted some of the stable/occasional components from the collective human mobility in the Beijing subway and found that the departure and arrival mobility patterns have different characteristics, both in time and space, under various conditions. We classified individual records into different patterns and analyzed the most likely trip distance by category. The proposed method can decompose stable/occasional mobility patterns from the collective mobility and identify passengers belonging to different patterns, helping us to better understand the origin of different mobility patterns and provide guidance for emergency management of large crowds.

  7. Indoor radon distribution of subway stations in a Korean major city

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seokwon [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); Chang, Byung-Uck, E-mail: hafadai@kins.re.k [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); University of Science and Technology, Gwahak-ro 113, Yuseong-gu, 305-333 Daejeon (Korea, Republic of); Kim, Yongjae [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); Byun, Jong-In [University of Science and Technology, Gwahak-ro 113, Yuseong-gu, 305-333 Daejeon (Korea, Republic of); Yun, Ju-Yong [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); University of Science and Technology, Gwahak-ro 113, Yuseong-gu, 305-333 Daejeon (Korea, Republic of)

    2010-04-15

    The overall survey on indoor radon concentration was conducted at all subway stations in a major city, Daejeon in the central part of Korea. It was quarterly performed from September 2007 to August 2008. The annual arithmetic mean of indoor radon concentration of all the stations was 34.1 +- 14.7 Bq m{sup -3}, and the range of values was from 9.4 to 98.2 Bq m{sup -3}. The radon concentrations in groundwater (average 31.0 +- 0.8 Bq m{sup -3}) were not significantly high in most stations, but the concentration (177.9 +- 2.3 Bq L{sup -1}) of one station was over the level of 148 Bq L{sup -1} in drinking water proposed by U.S. EPA. Based on indoor survey results, the approximate average of the annual effective dose by radon inhalation to the employees and passengers were 0.24 mSv y{sup -1}, and 0.02 mSv y{sup -1}, respectively. Although the effective dose based on the UNSCEAR report was potentially estimated, for more accurate assessment, the additional survey on the influence by indoor radon will be necessary.

  8. NeuroLines: A Subway Map Metaphor for Visualizing Nanoscale Neuronal Connectivity.

    Science.gov (United States)

    Al-Awami, Ali K; Beyer, Johanna; Strobelt, Hendrik; Kasthuri, Narayanan; Lichtman, Jeff W; Pfister, Hanspeter; Hadwiger, Markus

    2014-12-01

    We present NeuroLines, a novel visualization technique designed for scalable detailed analysis of neuronal connectivity at the nanoscale level. The topology of 3D brain tissue data is abstracted into a multi-scale, relative distance-preserving subway map visualization that allows domain scientists to conduct an interactive analysis of neurons and their connectivity. Nanoscale connectomics aims at reverse-engineering the wiring of the brain. Reconstructing and analyzing the detailed connectivity of neurons and neurites (axons, dendrites) will be crucial for understanding the brain and its development and diseases. However, the enormous scale and complexity of nanoscale neuronal connectivity pose big challenges to existing visualization techniques in terms of scalability. NeuroLines offers a scalable visualization framework that can interactively render thousands of neurites, and that supports the detailed analysis of neuronal structures and their connectivity. We describe and analyze the design of NeuroLines based on two real-world use-cases of our collaborators in developmental neuroscience, and investigate its scalability to large-scale neuronal connectivity data.

  9. Persuasion to use personal protective equipment in constructing subway stations: application of social marketing.

    Science.gov (United States)

    Shamsi, Mahmoud; Pariani, Abbas; Shams, Mohsen; Soleymani-nejad, Marzieh

    2016-04-01

    To study the effects of an intervention based on social marketing to persuade workers to use personal protective equipment (PPE) in constructing subway stations in Isfahan, Iran. This was a quasi-experimental study. Two stations were selected as intervention and control groups. Intervention was designed based on results of a formative research. A free package containing a safety helmet with a tailored message affixed to it, mask and gloves and an educational pamphlet was delivered to the intervention group. After 6 weeks, behaviours in the intervention and control stations were measured using an observational checklist. After the intervention, the percentage of workers who used PPE at the intervention station increased significantly. OR for helmet and mask usage was 7.009 and 2.235, respectively, in the intervention group. Social marketing can be used to persuade workers to use PPE in the workplace. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Automatic and efficient methods applied to the binarization of a subway map

    Science.gov (United States)

    Durand, Philippe; Ghorbanzadeh, Dariush; Jaupi, Luan

    2015-12-01

    The purpose of this paper is the study of efficient methods for image binarization. The objective of the work is the metro maps binarization. the goal is to binarize, avoiding noise to disturb the reading of subway stations. Different methods have been tested. By this way, a method given by Otsu gives particularly interesting results. The difficulty of the binarization is the choice of this threshold in order to reconstruct. Image sticky as possible to reality. Vectorization is a step subsequent to that of the binarization. It is to retrieve the coordinates points containing information and to store them in the two matrices X and Y. Subsequently, these matrices can be exported to a file format 'CSV' (Comma Separated Value) enabling us to deal with them in a variety of software including Excel. The algorithm uses quite a time calculation in Matlab because it is composed of two "for" loops nested. But the "for" loops are poorly supported by Matlab, especially in each other. This therefore penalizes the computation time, but seems the only method to do this.

  11. Geological Hazards analysis in Urban Tunneling by EPB Machine (Case study: Tehran subway line 7 tunnel

    Directory of Open Access Journals (Sweden)

    Hassan Bakhshandeh Amnieh

    2016-06-01

    Full Text Available Technological progress in tunneling has led to modern and efficient tunneling methods in vast underground spaces even under inappropriate geological conditions. Identification and access to appropriate and sufficient geological hazard data are key elements to successful construction of underground structures. Choice of the method, excavation machine, and prediction of suitable solutions to overcome undesirable conditions depend on geological studies and hazard analysis. Identifying and investigating the ground hazards in excavating urban tunnels by an EPB machine could augment the strategy for improving soil conditions during excavation operations. In this paper, challenges such as geological hazards, abrasion of the machine cutting tools, clogging around these tools and inside the chamber, diverse work front, severe water level fluctuations, existence of water, and fine-grained particles in the route were recognized in a study of Tehran subway line 7, for which solutions such as low speed boring, regular cutter head checks, application of soil improving agents, and appropriate grouting were presented and discussed. Due to the presence of fine particles in the route, foam employment was suggested as the optimum strategy where no filler is needed.

  12. Discovery Mondays - Men of fire: the fire brigade show their mettle

    CERN Multimedia

    2004-01-01

    Flashover and backdraught, these technical terms refer to two of the most dangerous phenomena associated with fires. In order to train in dealing with them, in the course of their fire fighting duties the CERN fire brigade use special simulation equipment. The demonstrations are rather spectacular... Thrills are therefore guaranteed at the next Discovery Monday on 2 February! In the course of the evening, you will see fire-fighters demonstrate climbing techniques including abseiling, a method they would have to use to access underground structures on the CERN site in the event of an accident. The accomplished climbers (the Hazardous Environments Response Team) will provide detailed explanations of the rescue techniques and procedures they use in tunnels and hazardous environments. CERN firemen simulate the backdraft phenomena for training. The demonstration, which you will have the opportunity to observe, on the next Discovery Monday, is spectacular. However, the remit of the CERN fire brigade goes well b...

  13. Industrial safety and fire protection during the construction phase

    International Nuclear Information System (INIS)

    Zimmer, K.

    1977-01-01

    The questions and problems of industrial safety and fire prevention have to be treated like the activities planning, developing, assembly, etc. This statement is illustrated by statistics of the fire insurance companies, from which it can be seen that the number of fire accidents has decreased but that the damage caused has greatly increased. The sooner the fire prevention and industrial safety measures are integrated in the planning phase, the better for the total costs. Preventive measures that possibly have to be introduced at a later stage are not only generally much more expensive but are also seldom as effective. (orig./HK) [de

  14. The characters of emergency rescue and the measures to prevent accidents for nuclear-powered submarine

    International Nuclear Information System (INIS)

    Wang Yuexing

    1999-01-01

    The characteristics of emergency rescue and the measures for preventing and decreasing accidents in nuclear-powered submarine have been presented. The breakdown of equipment and human factors are the main reasons which lead to accidents. Four preventive measures are suggested: enhancing capabilities to take precautions against fire, seriously controlling the environmental factors which affect the health of the submariners, reinforcing the constitutions of the submariners, and working out emergency planning against serious accidents in advance

  15. Fire Models and Design Fires

    DEFF Research Database (Denmark)

    Poulsen, Annemarie

    The aim of this project is to perform an experimental study on the influence of the thermal feedback on the burning behavior of well ventilated pre-flashover fires. For the purpose an experimental method has been developed. Here the same identical objects are tested under free burn conditions...... carried out by Carleton University and NRC-IRC performed on seven different types of fire loads representing commercial premises, comprise the tests used for the study. The results show that for some of the room test the heat release rate increased due to thermal feedback compared to free burn for a pre......-flashover fire. Two phenomena were observed, that relate well to theory was found. In an incipient phase the heat release rate rose with the temperature of the smoke layer/enclosure boundaries. This increase was also found to depend on the flammability properties of the burning object. The results also...

  16. Chernobyl accident. Exposures and effects

    International Nuclear Information System (INIS)

    Bennett, B.; Bouville, A.; Hall, P.; Savkin, M.; Storm, H.

    2000-01-01

    The Chernobyl accident that occurred in Ukraine in April 1986 happened during an experimental test of the electrical control system as the reactor was being shut down for routine maintenance. The operators, in violation of safety regulations, had switched off important control systems and allowed the reactor to reach unstable, low-power conditions. A sudden power surge caused a steam explosion that ruptured the reactor vessel and allowed further violent fuel-steam interactions that destroyed the reactor and the reactor building. The Chernobyl accident was the most serious to have ever occurred in the nuclear power industry. The accident caused the early death of 30 power plant employees and fire fighters and resulted in widespread radioactive contamination in areas of Belarus, the Russian Federation, and Ukraine inhabited by several million people. Radionuclides released from the reactor that caused exposure of individuals were mainly iodine-131, caesium-134 and caesium-137. Iodine-131 has a short radioactive half-life (8 days), but it can be transferred relatively rapidly through milk and leafy vegetables to humans. Iodine becomes localized in the thyroid gland. For reasons of intake of these foods, size of thyroid gland and metabolism, the thyroid doses are usually greater to infants and children than to adults. The isotopes of caesium have relatively long half-lives (caesium-134: 2 years; caesium-137: 30 years). These radionuclides cause long-term exposures through the ingestion pathway and from external exposure to these radionuclides deposited on the ground. In addition to radiation exposure, the accident caused long-term changes in the lives of people living in the contaminated regions, since measures intended to limit radiation doses included resettlements, changes in food supplies, and restrictions in activities of individuals and families. These changes were accompanied by major economic, social and political changes in the affected countries resulting

  17. Constructing a generalized network design model to study air distribution in ventilation networks in subway with a single-track tunnel

    Science.gov (United States)

    Lugin, IV

    2018-03-01

    In focus are the features of construction of the generalized design model for the network method to study air distribution in ventilation system in subway with the single-track tunnel. The generalizations, assumptions and simplifications included in the model are specified. The air distribution is calculated with regard to the influence of topology and air resistances of the ventilation network sections. The author studies two variants of the subway line: half-open and closed with dead end on the both sides. It is found that the total air exchange at a subway station depends on the station location within the line. The operating mode of fans remains unaltered in this case. The article shows that elimination of air leakage in the station ventilation room allows an increase in the air flow rate by 7–8% at the same energy consumption by fans. The influence of the stop of a train in the tunnel on the air distribution is illustrated.

  18. Application of computational fluid dynamics and pedestrian-behavior simulations to the design of task-ambient air-conditioning systems of a subway station

    Energy Technology Data Exchange (ETDEWEB)

    Fukuyo, Kazuhiro [Graduate School of Innovation and Technology Management, Faculty of Engineering, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi 755-8611 (Japan)

    2006-04-15

    The effects of task-ambient (TA) air-conditioning systems on the air-conditioning loads in a subway station and the thermal comfort of passengers were studied using computational fluid dynamics (CFD) and pedestrian-behavior simulations. The pedestrian-behavior model was applied to a standard subway station. Task areas were set up to match with crowdedness as predicted by the pedestrian-behavior simulations. Subsequently, a variety of TA air-conditioning systems were designed to selectively control the microclimate of the task areas. Their effects on the thermal environment in the station in winter were predicted by CFD. The results were compared with those of a conventional air-conditioning system and evaluated in relation to the thermal comfort of subway users and the air-conditioning loads. The comparison showed that TA air-conditioning systems improved thermal comfort and decreased air-conditioning loads. (author)

  19. Experience from the Inspection of Licensees' Outage Activities, Including Fire Protection Programmes, Event Response Inspections, and the Impact of the Fukushima Daiichi NPP Accident on Inspection Programmes. Workshop Proceedings, Chattanooga, Tennessee, United States, 7-10 April 2014 - Appendix: Compilation of Survey Responses

    International Nuclear Information System (INIS)

    2014-10-01

    This appendix provides the complete compilation of responses received to the questionnaire issued in conjunction with the workshop announcements. The responses are provided as received, with changes made only to the formatting. The OECD Nuclear Energy Agency (NEA) Committee on Nuclear Regulatory Activities (CNRA) Working Group on Inspection Practices (WGIP) sponsored the 12. International Workshop on Nuclear Regulatory Inspection Activities. The workshop was hosted by the U.S. NRC, in Chattanooga, Tennessee, United States of America on 7 -10 April 2014. The three workshop topics that were addressed were as follows: - Inspection of Outage Activities Including Fire Protection Programmes. - Event Response Inspections. - The Impact of Inspection Programmes of the Fukushima Daiichi NPP Accident. Each of the respondents was given the following instructions in relation to their response: - Only one response per country is required. If more than one person from your country is participating, please co-ordinate the responses accordingly. - Please provide responses on separate sheet and clearly identify the questionnaire part and topic. For preparation of the workshop, participants are invited to supply their national inspection approaches used in inspection of events and incidents according to the surveys. Actual issues that were discussed during the workshop were generated by the topic leaders based on the responses submitted by participants with their registration forms. This formats helps to ensure that issues considered most important by the workshop participants are covered during the group discussions. (authors)

  20. UF{sub 6} cylinder fire test

    Energy Technology Data Exchange (ETDEWEB)

    Park, S.H. [Oak Ridge K-25 Site, Oak Ridge, TN (United States)

    1991-12-31

    With the increasing number of nuclear reactors for power generation, there is a comparable increase in the amount of UF{sub 6} being transported. Likewise, the probability of having an accident involving UF{sub 6}-filled cylinders also increases. Accident scenarios which have been difficult to assess are those involving a filled UF{sub 6} cylinder subjected to fire. A study is underway at the Oak Ridge K-25 Site, as part of the US DOE Enrichment Program, to provide empirical data and a computer model that can be used to evaluate various cylinder-in-fire scenarios. It is expected that the results will provide information leading to better handling of possible fire accidents as well as show whether changes should be made to provide different physical protection during shipment. The computer model being developed will be capable of predicting the rupture of various cylinder sizes and designs as well as the amount of UF{sub 6}, its distribution in the cylinder, and the conditions of the fire.

  1. Filtration of sodium-fire aerosols

    International Nuclear Information System (INIS)

    Alexas, A.; Jordan, S.; Lindner, W.

    1979-01-01

    Different filter devices have been developed and tested with respect to their use in the off-gas system of liquid-metal fast breeder reactors to prevent the escape of sodium-fire aerosols that might be formed in case of an accident. The testing results have shown that the use of a multilayer sand bed filter is still the best method to filter limited amounts of sodium-fire aerosols over a long operating time. Efficiencies on the order of 99.98 and 98.8% were reached for loading capacities of 500 and 1000 g/m 2 , respectively. Unlimited amounts of sodium-fire aerosols can be filtered by wet scrubbers with an efficiency of 70% per scrubber stage. Fiberglas filters connot be used for the filtration of sodium-fire aerosols over a long operating time because the filter material can be destroyed after several days of operating

  2. Heat transfer studies in pool fire environment

    International Nuclear Information System (INIS)

    Nitsche, F.

    1993-01-01

    A Type B package has to withstand severe thermal accident conditions. To calculate the temperature behaviour of such a package in a real fire environment, heat transfer parameters simulating the effect of the fire are needed. For studying such heat transfer parameters, a systematic programme of experimental and theoretical investigations was performed which was part of the IAEA Coordinated Research Programme (Nitsche and Weib 1990). The studies were done by means of small, unfinned and finned, steel model containers of simplified design in hydrocarbon fuel open fire tests. By using various methods, flame and container temperatures were measured and also container surface absorptivity before and after the test to study the effect of sooting and surface painting on heat transfer. Based on all these experimental data and comparative calculations, simplified, effective heat transfer parameters could be derived, simulating the effect of the real fire on the model containers. (J.P.N.)

  3. Prevention of cable fires in nuclear power plants

    International Nuclear Information System (INIS)

    Murota, George; Yajima, Kazuo

    1979-01-01

    Nuclear power generation is indispensable to secure required electric power, therefore double or triple safety measures are necessary to prevent serious accidents absolutely. As for the countermeasures to cable fires, interest grew rapidly with the fire in Browns Ferry Power Station in USA in 1975 as the turning point, because multi-strand grouped cables caused to promote the spread of fire. In Japan, also the fire prevention measures for wires and cables were more strengthened, and the measures for preventing the spread of cable fires with the agent preventing the spread of fires have occupied the important position. When multi-strand cables are ignited by some cause, the fire spreads with very large combustion force along wirings to other rooms and installations, and electric systems are broken down. The harmful corrosive gas generated from the burning coating materials of cables diffuses very quickly. In nuclear power stations, the cables which are very hard to burn are adopted, fire prevention sections are established positively, the fire-resisting capability of fire prevention barriers is reviewed, and fire-resisting and smoke-preventing treatments are applied to the parts where cables penetrate walls, floors or ceilings. The paint and the sealing material which prevent the spread of fires are introduced. (Kako, I.)

  4. Steel dust in the New York City subway system as a source of manganese, chromium, and iron exposures for transit workers.

    Science.gov (United States)

    Chillrud, Steven N; Grass, David; Ross, James M; Coulibaly, Drissa; Slavkovich, Vesna; Epstein, David; Sax, Sonja N; Pederson, Dee; Johnson, David; Spengler, John D; Kinney, Patrick L; Simpson, H James; Brandt-Rauf, Paul

    2005-03-01

    The United States Clean Air Act Amendments of 1990 reflected increasing concern about potential effects of low-level airborne metal exposure on a wide array of illnesses. Here we summarize results demonstrating that the New York City (NYC) subway system provides an important microenvironment for metal exposures for NYC commuters and subway workers and also describe an ongoing pilot study of NYC transit workers' exposure to steel dust. Results from the TEACH (Toxic Exposure Assessment, a Columbia and Harvard) study in 1999 of 41 high-school students strongly suggest that elevated levels of iron, manganese, and chromium in personal air samples were due to exposure to steel dust in the NYC subway. Airborne concentrations of these three metals associated with fine particulate matter were observed to be more than 100 times greater in the subway environment than in home indoor or outdoor settings in NYC. While there are currently no known health effects at the airborne levels observed in the subway system, the primary aim of the ongoing pilot study is to ascertain whether the levels of these metals in the subway air affect concentrations of these metals or related metabolites in the blood or urine of exposed transit workers, who due to their job activities could plausibly have appreciably higher exposures than typical commuters. The study design involves recruitment of 40 transit workers representing a large range in expected exposures to steel dust, the collection of personal air samples of fine particulate matter, and the collection of blood and urine samples from each monitored transit worker.

  5. Synergy effect in accident simulation

    International Nuclear Information System (INIS)

    Alba, C.; Carlin, F.; Chenion, J.; Gaussens, G.; Le Meur, M.; Petitjean, M.

    1984-05-01

    Accidental breaking of PWR coolant canalization would entail water vaporization into confinement enclosure. Equipments would be simultaneously subjected to temperature and pressure increase, chemical spray, and radiation action of reactor core products. Some equipments have to work after accident in order to stop reactor running and blow out water calories. Usually, in France, accident simulation tests are carried out sequentialy: irradiation followed by thermodynamical and chemical tests. Equipments working is essentially due to those polymer materials behaviour. Is the polymers behaviour the same when they are either subjected to sequential test, or an accident (simultaneous action of irradiation and thermodynamical and chemical sequence). In order to answer to this question, nine polymer materials were subjected to simultaneous and sequential test in CESAR cell. Experiments were carried out in CESAR device with thermodynamical chocks and a temperature and pressure decrease profil in presence or without irradiation. So, the test is either simultaneous or sequential. Mechanical properties change are determined for the following polymeric materials. Two polyamide-imide varnishes used in motors and coils; one epoxydic resin, glass fiber charged (electrical insulating); polyphenylene sulfide, glass fiber charged, the Ryton R4 (electrical insulating); three elastomeric materials: Hypalon, fire proof by bromine or by alumina EPDM (cables jacket); VAMAC which is a polyethylene methyl polymethacrylate copolymer; then a silicon thermoset material glass fiber charged (electrical insulating). After test, usually, mechanical and electrical properties change of polymer materials show sequential experiment is more severe than simultaneous test however, Hypalon does not follow this law. For this polymer simultaneous test appears more severe than sequential experiment [fr

  6. Visualization of Traffic Accidents

    Science.gov (United States)

    Wang, Jie; Shen, Yuzhong; Khattak, Asad

    2010-01-01

    Traffic accidents have tremendous impact on society. Annually approximately 6.4 million vehicle accidents are reported by police in the US and nearly half of them result in catastrophic injuries. Visualizations of traffic accidents using geographic information systems (GIS) greatly facilitate handling and analysis of traffic accidents in many aspects. Environmental Systems Research Institute (ESRI), Inc. is the world leader in GIS research and development. ArcGIS, a software package developed by ESRI, has the capabilities to display events associated with a road network, such as accident locations, and pavement quality. But when event locations related to a road network are processed, the existing algorithm used by ArcGIS does not utilize all the information related to the routes of the road network and produces erroneous visualization results of event locations. This software bug causes serious problems for applications in which accurate location information is critical for emergency responses, such as traffic accidents. This paper aims to address this problem and proposes an improved method that utilizes all relevant information of traffic accidents, namely, route number, direction, and mile post, and extracts correct event locations for accurate traffic accident visualization and analysis. The proposed method generates a new shape file for traffic accidents and displays them on top of the existing road network in ArcGIS. Visualization of traffic accidents along Hampton Roads Bridge Tunnel is included to demonstrate the effectiveness of the proposed method.

  7. Key techniques and risk management for the application of the Pile-Beam-Arch (PBA) excavation method: a case study of the Zhongjie subway station.

    Science.gov (United States)

    Guan, Yong-ping; Zhao, Wen; Li, Shen-gang; Zhang, Guo-bin

    2014-01-01

    The design and construction of shallow-buried tunnels in densely populated urban areas involve many challenges. The ground movements induced by tunneling effects pose potential risks to infrastructure such as surface buildings, pipelines, and roads. In this paper, a case study of the Zhongjie subway station located in Shenyang, China, is examined to investigate the key construction techniques and the influence of the Pile-Beam-Arch (PBA) excavation method on the surrounding environment. This case study discusses the primary risk factors affecting the environmental safety and summarizes the corresponding risk mitigation measures and key techniques for subway station construction using the PBA excavation method in a densely populated urban area.

  8. SFR Safety Consideration in Light of Fukushima Dai-ichi Accident

    International Nuclear Information System (INIS)

    Yamaguchi, Akira

    2013-01-01

    SFR Considerations: Fukushima Dai-ichi Accident: • Combined LORL and LOHS type initiated from SBO; • High pressure water-steam cooling system: – Depressurization - Not needed; – Ultimate heat sink - Robust (NC to atmosphere); – Continuous injection - Not needed (large sensible heat capacity). • Severe accident management: – RPV failure resulted in depressurization - Elevated temperature; – Heat sink to atmosphere - Freeing risk, sodium fire risk; – Mobile power supply - External resource may not be needed; – Seawater injection with fire engines - Sodium injection not needed; • Containment performance and accessibility: – Containment - Large containment volume and low pressure system; – Explosives - Sodium fire and hydrogen explosion

  9. Fire Behavior (FB)

    Science.gov (United States)

    Robert E. Keane

    2006-01-01

    The Fire Behavior (FB) method is used to describe the behavior of the fire and the ambient weather and fuel conditions that influence the fire behavior. Fire behavior methods are not plot based and are collected by fire event and time-date. In general, the fire behavior data are used to interpret the fire effects documented in the plot-level sampling. Unlike the other...

  10. Uncertainty analysis for parameters of CFAST in the main control room fire scenario

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wanhong; Guo, Yun; Peng, Changhong [Univ. of Science and Technology of China No. 96, Anhui (China). School of Nuclear Science and Technology

    2017-07-15

    The fire accident is one of important initial events in the nuclear power plant. Moreover, the fire development process is extremely difficult and complex to predict accurately. As a result, the plant internal fire accidents have become one of the most realistic threat on the safety of the nuclear power plants. The main control room contains all the control and monitoring equipment that operators need. Once it is on fire, hostile environments would greatly impact on the safety of human operations. Therefore, fire probability safety analysis on the main control room has become a significant task. By using CFAST and Monte Carlo sampling method as a tool for fire modeling to simulate main control room on fire, we can examine uncertainty analysis for the important parameters of CFAST.

  11. Hamburg subway vehicles with new control and traction systems; Hamburger U-Bahn-Fahrzeuge mit neuer Leit- und Antriebstechnik

    Energy Technology Data Exchange (ETDEWEB)

    Polster, H.J.; Lehr, G.; Werner-Wieland, P. [Bombardier Transportation, LRV, Mannheim (Germany)

    2007-07-01

    With a view to testing new technologies for future vehicle series for the Hamburg subway network, the last 17 DT4 cars to be delivered under a current contract were equipped with the latest generation of control and traction systems. A MITRAC control system was installed instead of the MICAS-S type used in the DT4 vehicles delivered before. The GTO converters were replaced by IGBT elements. The concept is designed to allow for the change-over of DT4 vehicles of previous series to the new system. (orig.)

  12. Fire Symfonier

    DEFF Research Database (Denmark)

    Nielsen, Svend Hvidtfelt

    2009-01-01

    sidste fire symfonier. Den er måske snarere at opfatte som et præludium til disse. At påstå, at symfonierne fra Holmboes side er planlagt til at være beslægtede, ville være at gå for vidt. Alene de 26 år, der skiller den 10. fra den 13., gør påstanden - i bedste fald - dubiøs. Når deres udformning...... udkrystallisering som i de sidste små 30 år af hans virke har afkastet disse fire variationer over en grundlæggende central holmboesk fornemmelse for form, melodi, klang og rytme. Denne oplevelse har fået mig til at udforske symfonierne, for at finde til bunds i dette holmboeske fællestræk, som jeg mener her står...

  13. The Chernobyl accident consequences

    International Nuclear Information System (INIS)

    2001-04-01

    Five teen years later, Tchernobyl remains the symbol of the greater industrial nuclear accident. To take stock on this accident, this paper proposes a chronology of the events and presents the opinion of many international and national organizations. It provides also web sites references concerning the environmental and sanitary consequences of the Tchernobyl accident, the economic actions and propositions for the nuclear safety improvement in the East Europe. (A.L.B.)

  14. Radiation, accidents, society

    International Nuclear Information System (INIS)

    1988-01-01

    This book is meant to be used as a reference book for information officers at the event of a nuclear accident. The main part is edited in alphabetical order to facilitate use under stress. The book gives a short review of the health risks of radiation, and descriptions of accidents that have occured. The index words that have been chosen for the main part of the book have been selected due to experiences in connection with incidents and accidents. (L.E.)

  15. Reactivity insertion accident analysis

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Nakata, H.; Yorihaz, H.

    1990-04-01

    The correct prediction of postulated accidents is the fundamental requirement for the reactor licensing procedures. Accident sequences and severity of their consequences depend upon the analysis which rely on analytical tools which must be validated against known experimental results. Present work presents a systematic approach to analyse and estimate the reactivity insertion accident sequences. The methodology is based on the CINETHICA code which solves the point-kinetics/thermohydraulic coupled equations with weighted temperature feedback. Comparison against SPERT experimental results shows good agreement for the step insertion accidents. (author) [pt

  16. Nuclear accidents and epidemiology

    International Nuclear Information System (INIS)

    1987-01-01

    A consultation on epidemiology related to the Chernobyl accident was held in Copenhagen in May 1987 as a basis for concerted action. This was followed by a joint IAEA/WHO workshop in Vienna, which reviewed appropriate methodologies for possible long-term effects of radiation following nuclear accidents. The reports of these two meetings are included in this volume, and cover the subjects: 1) Epidemiology related to the Chernobyl nuclear accident. 2) Appropriate methodologies for studying possible long-term effects of radiation on individuals exposed in a nuclear accident. Figs and tabs

  17. Accidents (FARS) (National)

    Data.gov (United States)

    Department of Transportation — Accident - (1975-current): This data file (NTAD) contains information about crash characteristics and environmental conditions at the time of the crash. There is one...

  18. A methodology for the transfer of probabilities between accident severity categories

    International Nuclear Information System (INIS)

    Whitlow, J.D.; Neuhauser, K.S.

    1992-01-01

    Evaluation of the radiological risks of accidents involving vehicles transporting radioactive materials requires consideration of both accident probability and consequences. The probability that an accident will occur may be estimated from historical accident data for the given mode of transport. In addition to an overall accident rate, information regarding accident severity and the resulting package environments across the range of all credible accidents is needed to determine the potential for a release of radioactive material from the package or for an increase in direct radiation from the package caused by damage to packaging shielding. This information is usually obtained from a variety of sources such as historical data, experimental data, analyses of accident and package environments, and expert opinion. The consequences of an accident depend on a number of factors including the type, quantity, and physical form of radioactive material being transported; the response of the package to accident environments; the fraction of material released from the package; and the dispersion of any released material. One approach for the classification and treatment of transportation accidents in risk analysis divides the complete range of critical accident environments resulting from all credible accidents into some number of accident-severity categories. The types of accident environments that a package may be subjected to in transportation are often classified into the following five groups: impact, fire, crush, puncture, and immersion. A open-quotes criticalclose quotes accident environment is one of a type that could present a plausible threat to a package. Each severity category represents a portion of all credible accidents, and the total of all severity categories covers the complete range of critical accident environments. This approach is used in the risk assessment codes RADTRAN (Neuhauser and Kanipe 1992) and INTERTRAN (Ericsson and Elert 1983)

  19. Optimizing a desirable fare structure for a bus-subway corridor.

    Science.gov (United States)

    Liu, Bing-Zheng; Ge, Ying-En; Cao, Kai; Jiang, Xi; Meng, Lingyun; Liu, Ding; Gao, Yunfeng

    2017-01-01

    This paper aims to optimize a desirable fare structure for the public transit service along a bus-subway corridor with the consideration of those factors related to equity in trip, including travel distance and comfort level. The travel distance factor is represented by the distance-based fare strategy, which is an existing differential strategy. The comfort level one is considered in the area-based fare strategy which is a new differential strategy defined in this paper. Both factors are referred to by the combined fare strategy which is composed of distance-based and area-based fare strategies. The flat fare strategy is applied to determine a reference level of social welfare and obtain the general passenger flow along transit lines, which is used to divide areas or zones along the corridor. This problem is formulated as a bi-level program, of which the upper level maximizes the social welfare and the lower level capturing traveler choice behavior is a variable-demand stochastic user equilibrium assignment model. A genetic algorithm is applied to solve the bi-level program while the method of successive averages is adopted to solve the lower-level model. A series of numerical experiments are carried out to illustrate the performance of the models and solution methods. Numerical results indicate that all three differential fare strategies play a better role in enhancing the social welfare than the flat fare strategy and that the fare structure under the combined fare strategy generates the highest social welfare and the largest resulting passenger demand, which implies that the more equity factors a differential fare strategy involves the more desirable fare structure the strategy has.

  20. Optimizing a desirable fare structure for a bus-subway corridor

    Science.gov (United States)

    Liu, Bing-Zheng; Ge, Ying-En; Cao, Kai; Jiang, Xi; Meng, Lingyun; Liu, Ding; Gao, Yunfeng

    2017-01-01

    This paper aims to optimize a desirable fare structure for the public transit service along a bus-subway corridor with the consideration of those factors related to equity in trip, including travel distance and comfort level. The travel distance factor is represented by the distance-based fare strategy, which is an existing differential strategy. The comfort level one is considered in the area-based fare strategy which is a new differential strategy defined in this paper. Both factors are referred to by the combined fare strategy which is composed of distance-based and area-based fare strategies. The flat fare strategy is applied to determine a reference level of social welfare and obtain the general passenger flow along transit lines, which is used to divide areas or zones along the corridor. This problem is formulated as a bi-level program, of which the upper level maximizes the social welfare and the lower level capturing traveler choice behavior is a variable-demand stochastic user equilibrium assignment model. A genetic algorithm is applied to solve the bi-level program while the method of successive averages is adopted to solve the lower-level model. A series of numerical experiments are carried out to illustrate the performance of the models and solution methods. Numerical results indicate that all three differential fare strategies play a better role in enhancing the social welfare than the flat fare strategy and that the fare structure under the combined fare strategy generates the highest social welfare and the largest resulting passenger demand, which implies that the more equity factors a differential fare strategy involves the more desirable fare structure the strategy has. PMID:28981508

  1. Browns Ferry fire

    International Nuclear Information System (INIS)

    Harkleroad, J.R.

    1983-01-01

    A synopsis of the March 22, 1975 fire at Browns Ferry Nuclear Plant is discussed. Emphasis is placed on events prior to and during the fire. How the fire started, fire fighting activities, fire and smoke development, and restoration activities are discussed

  2. Review of CNEN activities in the field of sodium fires

    Energy Technology Data Exchange (ETDEWEB)

    Gerosa, A [CNEN/CSN Casaccia, Rome (Italy)

    1979-03-01

    The problems related to sodium fires have received increased attention at CNEN in recent years. Sodium fires have been reported in several countries with a rate that is. relatively high if compared to the number of plants in operation. The consequences of fires have been usually quite limited but it appears that more adequate precautions could often be applied to minimize risk of more serious consequences. Many alternatives exist for fire prevention and for fire extinction, but the fact that many alternatives have not been sufficiently tested make choices rather difficult. CNEN has been facing the problem of sodium fire prevention and extinction in relation to: design of PEC reactor; design of experimental loops in its own centres (Casaccia and Brasimone); safe operation of the same loops and analysis of accidents and potential accident situations; design of facilities for sodium fire experiments; operation of sodium fire facilities; operation of sodium disposal facilities. It is worth mentioning that sodium is also utilized by italian concerns, where it is processed mostly as an intermediate product in the manufacture of tetraethyl lead. A recent accident in a TEL production plant in Italy (Trento in July 1978) has recently once more raised the question if provisions for sodium fire extinction were adequate. Small scale fires for training purposes have been performed by several experimenters at CNEN since 1965. A more systematic approach, initiated in 1973 at Brasimone Centre, has been interrupted after 1976 when studies for the construction of a larger experimental facility (SUPERSATANA) have been abandoned. In 1976 it was proposed a CNEN participation to the French Program ESMERALDA. An accord to run the ESMERALDA Project as a French-Italian common program has recently been taken. Experimental results are presented in this paper.

  3. Review of CNEN activities in the field of sodium fires

    International Nuclear Information System (INIS)

    Gerosa, A.

    1979-01-01

    The problems related to sodium fires have received increased attention at CNEN in recent years. Sodium fires have been reported in several countries with a rate that is. relatively high if compared to the number of plants in operation. The consequences of fires have been usually quite limited but it appears that more adequate precautions could often be applied to minimize risk of more serious consequences. Many alternatives exist for fire prevention and for fire extinction, but the fact that many alternatives have not been sufficiently tested make choices rather difficult. CNEN has been facing the problem of sodium fire prevention and extinction in relation to: design of PEC reactor; design of experimental loops in its own centres (Casaccia and Brasimone); safe operation of the same loops and analysis of accidents and potential accident situations; design of facilities for sodium fire experiments; operation of sodium fire facilities; operation of sodium disposal facilities. It is worth mentioning that sodium is also utilized by italian concerns, where it is processed mostly as an intermediate product in the manufacture of tetraethyl lead. A recent accident in a TEL production plant in Italy (Trento in July 1978) has recently once more raised the question if provisions for sodium fire extinction were adequate. Small scale fires for training purposes have been performed by several experimenters at CNEN since 1965. A more systematic approach, initiated in 1973 at Brasimone Centre, has been interrupted after 1976 when studies for the construction of a larger experimental facility (SUPERSATANA) have been abandoned. In 1976 it was proposed a CNEN participation to the French Program ESMERALDA. An accord to run the ESMERALDA Project as a French-Italian common program has recently been taken. Experimental results are presented in this paper

  4. A study on fire design accidental loads for aluminum safety helidecks

    Directory of Open Access Journals (Sweden)

    Sang Jin Kim

    2016-11-01

    Full Text Available The helideck structure must satisfy the safety requirements associated with various environmental and accidental loads. Especially, there have been a number of fire accidents offshore due to helicopter collision (take-off and/or landing in recent decades. To prevent further accidents, a substantial amount of effort has been directed toward the management of fire in the safety design of offshore helidecks. The aims of this study are to introduce and apply a procedure for quantitative risk assessment and management of fires by defining the fire loads with an applied example. The frequency of helicopter accidents are considered, and design accidental levels are applied. The proposed procedures for determining design fire loads can be efficiently applied in offshore helideck development projects.

  5. Domino effect in chemical accidents: main features and accident sequences

    OpenAIRE

    Casal Fàbrega, Joaquim; Darbra Roman, Rosa Maria

    2010-01-01

    The main features of domino accidents in process/storage plants and in the transportation of hazardous materials were studied through an analysis of 225 accidents involving this effect. Data on these accidents, which occurred after 1961, were taken from several sources. Aspects analyzed included the accident scenario, the type of accident, the materials involved, the causes and consequences and the most common accident sequences. The analysis showed that the most frequent causes a...

  6. Sodium pool fire model for CONACS code

    International Nuclear Information System (INIS)

    Yung, S.C.

    1982-01-01

    The modeling of sodium pool fires constitutes an important ingredient in conducting LMFBR accident analysis. Such modeling capability has recently come under scrutiny at Westinghouse Hanford Company (WHC) within the context of developing CONACS, the Containment Analysis Code System. One of the efforts in the CONACS program is to model various combustion processes anticipated to occur during postulated accident paths. This effort includes the selection or modification of an existing model and development of a new model if it clearly contributes to the program purpose. As part of this effort, a new sodium pool fire model has been developed that is directed at removing some of the deficiencies in the existing models, such as SOFIRE-II and FEUNA

  7. Characteristics of PM10 and CO2 concentrations on 100 underground subway station platforms in 2014 and 2015

    Science.gov (United States)

    Hwang, Sung Ho; Park, Wha Me; Park, Jae Bum; Nam, Taegyun

    2017-10-01

    In this study, the concentrations of particulate matter 10 μm or less in diameter (PM10) and carbon dioxide (CO2) were measured in 100 underground subway stations, and the potential health risks of PM10, and environmental factors affecting these concentrations were analyzed. The concentrations were measured from May 2014 to September 2015 in stations along Seoul Metro lines 1-4. There were significantly different PM10 concentrations among the underground subway stations along lines 1, 2, 3, and 4. The PM10 concentrations were associated with the CO2 concentrations, construction years, station depths, and numbers of passengers. The underground PM10 concentrations were significantly higher than the outdoor PM10 concentrations. In addition, the PM10 concentrations were higher in the stations that were constructed in the 1970s than in those constructed after the 1970s. The PM10 and CO2 concentrations varied significantly, depending on the construction year and number of passengers. The hazard quotient is higher than the acceptable level of 1.0 μg kg-1 day for children, indicating that they are at risk of exposure to unsafe PM10 levels when travelling by the metro. Therefore, stricter management may be necessary for the stations constructed in the 1970s as well as those with higher numbers of passengers.

  8. Radon and NO2 levels and related environmental factors in 100 underground subway platforms over two-year period.

    Science.gov (United States)

    Hwang, Sung Ho; Park, Jae Bum; Park, Wha Me

    2018-01-01

    In this study, the environmental factors that affect radon (Rn) and nitrogen dioxide (NO 2 ) levels in subway-station underground platforms are evaluated, and the outdoor NO 2 levels are compared with those obtained for the underground platforms. The Rn and NO 2 levels from May 2013 to September 2015 are determined for lines 1-4 of the Seoul Metro, via calculation of the arithmetic means of the Rn and NO 2 levels with their standard deviations (SDs). The underground Rn levels in 2013 are found to be significantly higher than those recorded in 2015 for the Seoul Metro. In addition, the Rn levels are related to the station depth and construction year. Further, the underground NO 2 levels are shown to be significantly higher than the outdoor levels for all four Seoul Metro subway lines. The Rn levels are also found to vary significantly between months, and are shown to increase gradually with depth from 8 to 20 m. The Rn levels are also higher for stations constructed in the 1980s. Therefore, stricter monitoring of Rn level may be required for stations constructed in the 1980s and/or having platform depths within the 8-20 m range. Island-type platform stations based on granite areas may also require careful attention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Influence of slab length on dynamic characteristics of subway train-steel spring floating slab track-tunnel coupled system

    Directory of Open Access Journals (Sweden)

    Qing-yuan Xu

    Full Text Available A subway train-steel spring floating slab track-tunnel coupling dynamic model, considering short and middle-long wavelength random track irregularities, and longitudinal connection between adjacent slabs of steel spring floating slab track, was developed. And the influence of slab length on dynamic characteristics of the system under different track conditions and train speeds are theoretically studied. The calculated results show: (1 In general, the acceleration of each component of the coupled system decreases with the increase of slab length under the perfectly smooth track condition; (2 Slab length has different influence laws on acceleration of each component of subway train-steel spring floating slab track-tunnel coupled system under random irregularity of track condition. The lower the dominant frequency distribution of vibration acceleration is, the higher influence slab length has; (3 With the increase of slab length, the force of rail, fastener and steel spring also decreases significantly, which helps to lengthen the service life of these components; (4 With the increase of slab length, the longitudinal bending moment of slab increases sharply at first, then it begins to drop slightly. When slab length exceeds the distance between two bogies of a vehicle, the longitudinal bending moment of slab changes little; (5 Slab length has significant influence on the dynamic force and displacement of the coupled system when train speed is higher.

  10. Chernobyl accident and Denmark

    International Nuclear Information System (INIS)

    1986-12-01

    The report describes the Chernobyl accident and its consequences for Denmark in particular. It was commissioned by The Secretary of State for the Environment. Volume 2 contains copies of original documents issued by Danish authorities during the first accident phase and afterwards. Evaluations, monitoring data, press releases, legislation acts etc. are included. (author)

  11. Criticality accident in Argentina

    International Nuclear Information System (INIS)

    Oliveira, A.R. de.

    1984-01-01

    A recent criticality type accident, ocurred in Argetina, is commented. Considerations about the nature of the facility where this accident took place, its genesis, type of operation carried out on the day of the event, and the medical aspects involved are done. (Author) [pt

  12. Chernobyl accident and Danmark

    International Nuclear Information System (INIS)

    1986-12-01

    The report describes the Chernobyl accident and its consequences for Denmark in particular. It was commissioned by the Secretary of State for the Environment. Volume 1 contains copies of original documents issued by Danish authorities during the first accident phase and afterwards. Evaluations, monitoring data, press releases, legislation acts etc. are included. (author)

  13. Communication and industrial accidents

    NARCIS (Netherlands)

    As, Sicco van

    2001-01-01

    This paper deals with the influence of organizational communication on safety. Accidents are actually caused by individual mistakes. However the underlying causes of accidents are often organizational. As a link between these two levels - the organizational failures and mistakes - I suggest the

  14. Chapter 6: Accidents

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2018-04-01

    Th chapter 6 presents the accidents of: 1) Stimos (Italy - May, 1975); 2) San Salvador (El Salvador - February 5, 1989); 3) Soreq (Israel - June 21, 1990); 4) Nesvizh (Belarus - October 26, 1991); 5) Illinois (USA - February, 1965); 6)Maryland (EUA - December 11, 1991); 7)Hanoi (Vietnam -November 17, 1992); 8)Fleurus (Belgium - March 11, 2006) and final remarks on accidents.

  15. Preliminary report about nuclear accident of Chernobylsk reactor

    International Nuclear Information System (INIS)

    Oliveira, A.R. de.

    1986-07-01

    The preliminary report of nuclear accident at Chernobyl, in URSS is presented. The Chernobyl site is located geographically and the RBMK type reactors - initials of russian words which mean high power pressure tube reactors are described. The conditions of reactor operation in beginning of accident, the events which lead to reactor destruction, the means to finish the fire, the measurements adopted by Russian in the accident location, the estimative of radioactive wastes, the meteorological conditions during the accident, the victims and medical assistence, the sanitary aspects and consequences for population, the evaluation of radiation doses received at small and medium distance and the estimative of reffered doses by population attained are presented. The official communication of Russian Minister Council and the declaration of IAEA general manager during a collective interview in Moscou are annexed. (M.C.K.) [pt

  16. Radiological accidents in medical practice

    International Nuclear Information System (INIS)

    Cardenas Herrera, Juan

    2012-01-01

    Different radiological accidents that may occur in medical practice are shown. The following topics are focused: accident statistics for medical exposure, accidental medical exposures, radiotherapy accidents and potential accidental scenarios [es

  17. Fire prevention in industrial installations presenting a risk for man and environment (ICPE); La prevention des incendies dans les ICPE: une exigence d'amelioration permanente

    Energy Technology Data Exchange (ETDEWEB)

    Moche, L. [Ministere de l' Amenagement du Territoire et de l' Environnement, Direction de la Prevention des Pollutions et des Risques, 75 - Paris (France)

    2000-09-01

    The most likely accident in industrial installations is fire. 59 out of 100 accidents reported in 1999 describe a fire outbreak, the fire is either the initiating cause of the accident or the form into which the event eventually evolves. This article briefly describes the why and the wherefore of French regulations on fire prevention in installations presenting a risk for man and environment. The French system is based on the responsibility of the plant operator and on the result of inspections performed by authorities to check the conformity of the installation with current regulations. (A.C.)

  18. Fire Ant Bites

    Science.gov (United States)

    ... Favorite Name: Category: Share: Yes No, Keep Private Fire Ant Bites Share | Fire ants are aggressive, venomous insects that have pinching ... across the United States, even into Puerto Rico. Fire ant stings usually occur on the feet or ...

  19. Fire safety at home

    Science.gov (United States)

    ... over the smoke alarm as needed. Using a fire extinguisher can put out a small fire to keep it from getting out of control. Tips for use include: Keep fire extinguishers in handy locations, at least one on ...

  20. Crown Fire Potential

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — Crown fire potential was modeled using FlamMap, an interagency fire behavior mapping and analysis program that computes potential fire behavior characteristics. The...

  1. National Fire Protection Association

    Science.gov (United States)

    ... closed NFPA Journal® NFPA Journal® Update (newsletter) Fire Technology ... die from American home fires, and another 13,000 are injured each year. This is the story of fire that the statistics won't show ...

  2. Statistical analysis of accident data associated with sea transport (invited paper)

    International Nuclear Information System (INIS)

    Raffestin, D.; Armingaud, F.; Schneider, T.; Delaigue, S.

    1998-01-01

    This analysis, based on Lloyd's database, gives an accurate description of the world fleet and the most severe ship accidents, as well as the frequencies of accident per ship type, accident category and age category. Complementary analyses were achieved using fire accident databases from AEA Technology and the French Bureau Veritas. The results should be used in the perspective of safety assessments of maritime shipments of radioactive material. For this purpose the existence of the regulations of the International Maritime Organisation has to be considered, leading to the introduction of correction factors to these statistical data derived from general cargo-carrying ships. (author)

  3. The international cooperation using the example of the reactor accident in Chernobyl

    International Nuclear Information System (INIS)

    Molitor, Norbert

    2017-01-01

    The explosion of the reactor unit 4 of the NPP Chernobyl and the subsequent fire was up to now the most severe accident in the civil nuclear industry. The consequences of the accident far outside the Ukraine and the former Soviet Union demonstrated that nuclear safety is a trans-border challenge. The mitigation of the accident consequences and the recovery of safety for the public, the workers and the environment required outstanding efforts and the international cooperation was of significant importance. The contribution discusses experiences and practical aspects of the international cooperation and implications for future cooperation options for the long-term removal of accident consequences.

  4. Genotoxic effects and oxidative stress induced by organic extracts of particulate matter(PM 10)collected from a subway tunnel in Seoul, Korea.

    Science.gov (United States)

    Jung, Mi Hyun; Kim, Ha Ryong; Park, Yong Joo; Park, Duck Shin; Chung, Kyu Hyuck; Oh, Seung Min

    2012-12-12

    Particulate matter (PM) has become an important health risk factor in our society. PM can easily deposit in the bronchi and lungs, causing diverse diseases such as respiratory infections, lung cancers and cardiovascular diseases. In recent days, more and more toxicological studies have been dealing with air particles in distinctive areas including industrial areas, transportation sites, or indoors. Studies on subway PM in particular, have been recognizing PM as an important health risk factor because many people use subways as a major mode of public transportation (4 million people a day in Korea). The main aim of the present study was to evaluate the genotoxic effects of organic extract (OE) of subway PM10 and potential attribution of PAHs to these effects. Particles were collected in the subway tunnel at Kil-eum station(Line 4) for one month and then extracted with Dichloromethane (DCM). Chinese Hamster Ovary cells(CHO-K1) and human normal bronchial cells (BEAS-2B) were exposed to OE, and MN and Comet assays were conducted to analyze the genotoxicity. The results showed that OE increased DNA or chromosome damages in both cell lines. In the modified Comet assay and MN assay with free radical scavengers, we confirmed that the genotoxic effect of OE was partially due to the oxidative damage on DNA. DCFHD Aassay also indicated that OE induced ROS generation in BEAS-2B cells. PAHs [benzo(a)anthracene,benzo(k)fluoranthrene, etc.], the most well-known carcinogens in polluted air, were detected in Kil-eum PM10. In conclusion, our findings confirmed that OE of subway PM10 has genotoxic effects on normal human lung cells, and oxidative stress could be one of the major mechanisms of these genotoxic effects.In addition, some genotoxic and carcinogenic PAHs were detected in OE by GC/MS/MS, even though PAHs level was not enough to increase CYP1A1 gene. Therefore, we suggest that additive or synergistic effects by unidentified chemicals as well as PAHs contained in OE of subway

  5. Cirrus Airframe Parachute System and Odds of a Fatal Accident in Cirrus Aircraft Crashes.

    Science.gov (United States)

    Alaziz, Mustafa; Stolfi, Adrienne; Olson, Dean M

    2017-06-01

    General aviation (GA) accidents have continued to demonstrate high fatality rates. Recently, ballistic parachute recovery systems (BPRS) have been introduced as a safety feature in some GA aircraft. This study evaluates the effectiveness and associated factors of the Cirrus Airframe Parachute System (CAPS) at reducing the odds of a fatal accident in Cirrus aircraft crashes. Publicly available Cirrus aircraft crash reports were obtained from the National Transportation Safety Board (NTSB) database for the period of January 1, 2001-December 31, 2016. Accident metrics were evaluated through univariate and multivariate analyses regarding odds of a fatal accident and use of the parachute system. Included in the study were 268 accidents. For CAPS nondeployed accidents, 82 of 211 (38.9%) were fatal as compared to 8 of 57 (14.0%) for CAPS deployed accidents. After controlling for all other factors, the adjusted odds ratio for a fatal accident when CAPS was not deployed was 13.1. The substantial increased odds of a fatal accident when CAPS was not deployed demonstrated the effectiveness of CAPS at providing protection of occupants during an accident. Injuries were shifted from fatal to serious or minor with the use of CAPS and postcrash fires were significantly reduced. These results suggest that BPRS could play a significant role in the next major advance in improving GA accident survival.Alaziz M, Stolfi A, Olson DM. Cirrus Airframe Parachute System and odds of a fatal accident in Cirrus aircraft crashes. Aerosp Med Hum Perform. 2017; 88(6):556-564.

  6. Response of HEPA filters to simulated-accident conditions

    International Nuclear Information System (INIS)

    Gregory, W.S.; Martin, R.A.; Smith, P.R.; Fenton, D.E.

    1982-01-01

    High-efficiency particulate air (HEPA) filters have been subjected to simulated accident conditions to determine their response to abnormal operating events. Both domestic and European standard and high-capacity filters have been evaluated to determine their response to simulated fire, explosion, and tornado conditions. The HEPA filter structural limitations for tornado and explosive loadings are discussed. In addition, filtration efficiencies during these accident conditions are reported for the first time. Our data indicate efficiencies between 80% and 90% for shock loadings below the structural limit level. We describe two types of testing for ineffective filtration - clean filters exposed to pulse-entrained aerosol and dirty filters exposed to tornado and shock pulses. Efficiency and material loss data are described. Also, the resonse of standard HEPA filters to simulated fire conditions is presented. We describe a unique method of measuring accumulated combustion products on the filter. Additionally, data relating to pressure drop vs accumulated mass during plugging are reported for simulated combustion aerosols. The effects of concentration and moisture levels on filter plugging were evaluated. We are obtaining all of the above data so that mathematical models can be developed for fire, explosion, and tornado accident analysis computer codes. These computer codes can be used to assess the response of nuclear air cleaning systems to accident conditions

  7. [Accidents and injuries at work].

    Science.gov (United States)

    Standke, W

    2014-06-01

    In the case of an accident at work, the person concerned is insured by law according to the guidelines of the Sozialgesetzbuch VII as far as the injuries have been caused by this accident. The most important source of information on the incident in question is the accident report that has to be sent to the responsible institution for statutory accident insurance and prevention by the employer, if the accident of the injured person is fatal or leads to an incapacity to work for more than 3 days (= reportable accident). Data concerning accidents like these are sent to the Deutsche Gesetzliche Unfallversicherung (DGUV) as part of a random sample survey by the institutions for statutory accident insurance and prevention and are analyzed statistically. Thus the key issues of accidents can be established and used for effective prevention. Although the success of effective accident prevention is undisputed, there were still 919,025 occupational accidents in 2011, with clear gender-related differences. Most occupational accidents involve the upper and lower extremities. Accidents are analyzed comprehensively and the results are published and made available to all interested parties in an effort to improve public awareness of possible accidents. Apart from reportable accidents, data on the new occupational accident pensions are also gathered and analyzed statistically. Thus, additional information is gained on accidents with extremely serious consequences and partly permanent injuries for the accident victims.

  8. FIRE CHARACTERISTICS FOR ADVANCED MODELLING OF FIRES

    OpenAIRE

    Otto Dvořák

    2016-01-01

    This paper summarizes the material and fire properties of solid flammable/combustible materials /substances /products, which are used as inputs for the computer numerical fire models. At the same time it gives the test standards for their determination.

  9. Database on aircraft accidents

    International Nuclear Information System (INIS)

    Nishio, Masahide; Koriyama, Tamio

    2012-09-01

    The Reactor Safety Subcommittee in the Nuclear Safety and Preservation Committee published the report 'The criteria on assessment of probability of aircraft crash into light water reactor facilities' as the standard method for evaluating probability of aircraft crash into nuclear reactor facilities in July 2002. In response to the report, Japan Nuclear Energy Safety Organization has been collecting open information on aircraft accidents of commercial airplanes, self-defense force (SDF) airplanes and US force airplanes every year since 2003, sorting out them and developing the database of aircraft accidents for latest 20 years to evaluate probability of aircraft crash into nuclear reactor facilities. This year, the database was revised by adding aircraft accidents in 2010 to the existing database and deleting aircraft accidents in 1991 from it, resulting in development of the revised 2011 database for latest 20 years from 1991 to 2010. Furthermore, the flight information on commercial aircrafts was also collected to develop the flight database for latest 20 years from 1991 to 2010 to evaluate probability of aircraft crash into reactor facilities. The method for developing the database of aircraft accidents to evaluate probability of aircraft crash into reactor facilities is based on the report 'The criteria on assessment of probability of aircraft crash into light water reactor facilities' described above. The 2011 revised database for latest 20 years from 1991 to 2010 shows the followings. The trend of the 2011 database changes little as compared to the last year's one. (1) The data of commercial aircraft accidents is based on 'Aircraft accident investigation reports of Japan transport safety board' of Ministry of Land, Infrastructure, Transport and Tourism. 4 large fixed-wing aircraft accidents, 58 small fixed-wing aircraft accidents, 5 large bladed aircraft accidents and 114 small bladed aircraft accidents occurred. The relevant accidents for evaluating

  10. Physiological responses and air consumption during simulated firefighting tasks in a subway system.

    Science.gov (United States)

    Williams-Bell, F Michael; Boisseau, Geoff; McGill, John; Kostiuk, Andrew; Hughson, Richard L

    2010-10-01

    Professional firefighters (33 men, 3 women), ranging in age from 30 to 53 years, participated in a simulation of a subway system search and rescue while breathing from their self-contained breathing apparatus (SCBA). We tested the hypothesis that during this task, established by expert firefighters to be of moderate intensity, the rate of air consumption would exceed the capacity of a nominal 30-min cylinder. Oxygen uptake, carbon dioxide output, and air consumption were measured with a portable breath-by-breath gas exchange analysis system, which was fully integrated with the expired port of the SCBA. The task involved descending a flight of stairs, walking, performing a search and rescue, retreat walking, then ascending a single flight of stairs to a safe exit. This scenario required between 9:56 and 13:24 min:s (mean, 12:10 ± 1:10 min:s) to complete, with an average oxygen uptake of 24.3 ± 4.5 mL kg(-1) min(-1) (47 ± 10 % peak oxygen uptake) and heart rate of 76% ± 7% of maximum. The highest energy requirement was during the final single-flight stair climb (30.4 ± 5.4 mL kg(-1) min(-1)). The average respiratory exchange ratio (carbon dioxide output/oxygen uptake) throughout the scenario was 0.95 ± 0.08, indicating a high carbon dioxide output for a relatively moderate average energy requirement. Air consumption from the nominal "30-min" cylinder averaged 51% (range, 26%-68%); however, extrapolation of these rates of consumption suggested that the low-air alarm, signalling that only 25% of the air remains, would have occurred as early as 11 min for an individual with the highest rate of air consumption, and at 16 min for the group average. These data suggest that even the moderate physical demands of walking combined with search and rescue while wearing full protective gear and breathing through the SCBA impose considerable physiological strain on professional firefighters. As well, the rate of air consumption in these tasks classed as moderate, compared

  11. Management of severe accidents

    International Nuclear Information System (INIS)

    Jankowski, M.W.

    1987-01-01

    The definition and the multidimensionality aspects of accident management have been reviewed. The suggested elements in the development of a programme for severe accident management have been identified and discussed. The strategies concentrate on the two tiered approaches. Operative management utilizes the plant's equipment and operators capabilities. The recovery managment concevtrates on preserving the containment, or delaying its failure, inhibiting the release, and on strategies once there has been a release. The inspiration for this paper was an excellent overview report on perspectives on managing severe accidents in commercial nuclear power plants and extending plant operating procedures into the severe accident regime; and by the most recent publication of the International Nuclear Safety Advisory Group (INSAG) considering the question of risk reduction and source term reduction through accident prevention, management and mitigation. The latter document concludes that 'active development of accident management measures by plant personnel can lead to very large reductions in source terms and risk', and goes further in considering and formulating the key issue: 'The most fruitful path to follow in reducing risk even further is through the planning of accident management.' (author)

  12. Management of severe accidents

    International Nuclear Information System (INIS)

    Jankowski, M.W.

    1988-01-01

    The definition and the multidimensionality aspects of accident management have been reviewed. The suggested elements in the development of a programme for severe accident management have been identified and discussed. The strategies concentrate on the two tiered approaches. Operative management utilizes the plant's equipment and operators capabilities. The recovery management concentrates on preserving the containment, or delaying its failure, inhibiting the release, and on strategies once there has been a release. The inspiration for this paper was an excellent overview report on perspectives on managing severe accidents in commercial nuclear power plants and extending plant operating procedures into the severe accident regime; and by the most recent publication of the International Nuclear Safety Advisory Group (INSAG) considering the question of risk reduction and source term reduction through accident prevention, management and mitigation. The latter document concludes that active development of accident management measures by plant personnel can lead to very large reductions in source terms and risk, and goes further in considering and formulating the key issue: The most fruitful path to follow in reducing risk even further is through the planning of accident management

  13. Persistence of airline accidents.

    Science.gov (United States)

    Barros, Carlos Pestana; Faria, Joao Ricardo; Gil-Alana, Luis Alberiko

    2010-10-01

    This paper expands on air travel accident research by examining the relationship between air travel accidents and airline traffic or volume in the period from 1927-2006. The theoretical model is based on a representative airline company that aims to maximise its profits, and it utilises a fractional integration approach in order to determine whether there is a persistent pattern over time with respect to air accidents and air traffic. Furthermore, the paper analyses how airline accidents are related to traffic using a fractional cointegration approach. It finds that airline accidents are persistent and that a (non-stationary) fractional cointegration relationship exists between total airline accidents and airline passengers, airline miles and airline revenues, with shocks that affect the long-run equilibrium disappearing in the very long term. Moreover, this relation is negative, which might be due to the fact that air travel is becoming safer and there is greater competition in the airline industry. Policy implications are derived for countering accident events, based on competition and regulation. © 2010 The Author(s). Journal compilation © Overseas Development Institute, 2010.

  14. Analyzing containment leakage from a sodium fire by the response surface method

    International Nuclear Information System (INIS)

    Person, L.W.

    1978-01-01

    The SPOOL-FIRE code has been used with the response surface method and a Monte Carlo simulation to study sodium fire accidents. The study provides a simple method of estimating the radioactive release via containment leakage; the sensitivity of the output consequences to the variations in the input parameters is also presented

  15. Spent fuel transportation cask response to a tunnel fire scenario

    Energy Technology Data Exchange (ETDEWEB)

    Bajwa, C.S. [U.S. Nuclear Regulatory Commission, Washington, D.C. (United States); Adkins, H.E.; Cuta, J.M. [Pacific Northwest National Lab., Richland, WA (United States)

    2004-07-01

    On July 18, 2001, a freight train carrying hazardous (non-nuclear) materials derailed and caught fire while passing through the Howard Street railroad tunnel in downtown Baltimore, Maryland. The United States Nuclear Regulatory Commission (USNRC), one of the agencies responsible for ensuring the safe transportation of radioactive materials in the United States, undertook an investigation of the train derailment and fire to determine the possible regulatory implications of this particular event for the transportation of spent nuclear fuel by railroad. Shortly after the accident occurred, the USNRC met with the National Transportation Safety Board (NTSB), the U.S. agency responsible for determining the cause of transportation accidents, to discuss the details of the accident and the ensuing fire. Following these discussions, the USNRC assembled a team of experts from the National Institute of Standards and Technology (NIST), the Center for Nuclear Waste Regulatory Analyses (CNWRA), and Pacific Northwest National Laboratory (PNNL) to determine the thermal conditions that existed in the Howard Street tunnel fire and analyze the effects of this fire on various spent fuel transportation cask designs. The Fire Dynamics Simulator (FDS) code, developed by NIST, was used to determine the thermal environment present in the Howard Street tunnel during the fire. The FDS results were used as boundary conditions in the ANSYS {sup registered} and COBRA-SFS computer codes to evaluate the thermal performance of different cask designs. The staff concluded that the transportation casks analyzed would withstand a fire with thermal conditions similar to those that existed in the Baltimore tunnel fire event. No release of radioactive materials would result from exposure of the casks analyzed to such an event. This paper describes the methods and approach used for this assessment.

  16. Spent fuel transportation cask response to a tunnel fire scenario

    International Nuclear Information System (INIS)

    Bajwa, C.S.; Adkins, H.E.; Cuta, J.M.

    2004-01-01

    On July 18, 2001, a freight train carrying hazardous (non-nuclear) materials derailed and caught fire while passing through the Howard Street railroad tunnel in downtown Baltimore, Maryland. The United States Nuclear Regulatory Commission (USNRC), one of the agencies responsible for ensuring the safe transportation of radioactive materials in the United States, undertook an investigation of the train derailment and fire to determine the possible regulatory implications of this particular event for the transportation of spent nuclear fuel by railroad. Shortly after the accident occurred, the USNRC met with the National Transportation Safety Board (NTSB), the U.S. agency responsible for determining the cause of transportation accidents, to discuss the details of the accident and the ensuing fire. Following these discussions, the USNRC assembled a team of experts from the National Institute of Standards and Technology (NIST), the Center for Nuclear Waste Regulatory Analyses (CNWRA), and Pacific Northwest National Laboratory (PNNL) to determine the thermal conditions that existed in the Howard Street tunnel fire and analyze the effects of this fire on various spent fuel transportation cask designs. The Fire Dynamics Simulator (FDS) code, developed by NIST, was used to determine the thermal environment present in the Howard Street tunnel during the fire. The FDS results were used as boundary conditions in the ANSYS registered and COBRA-SFS computer codes to evaluate the thermal performance of different cask designs. The staff concluded that the transportation casks analyzed would withstand a fire with thermal conditions similar to those that existed in the Baltimore tunnel fire event. No release of radioactive materials would result from exposure of the casks analyzed to such an event. This paper describes the methods and approach used for this assessment

  17. Fire and fire ecology: Concepts and principles

    Science.gov (United States)

    Mark A. Cochrane; Kevin C. Ryan

    2009-01-01

    Fire has been central to terrestrial life ever since early anaerobic microorganisms poisoned the atmosphere with oxygen and multicellular plant life moved onto land. The combination of fuels, oxygen, and heat gave birth to fire on Earth. Fire is not just another evolutionary challenge that life needed to overcome, it is, in fact, a core ecological process across much...

  18. General fire protection guidelines for egyptian nuclear facilities. Vol. 4

    Energy Technology Data Exchange (ETDEWEB)

    Radhad, S; Hussien, A Z; Hammad, F H [National Center for Nuclear Safety and Radiation Control, Atomic Energy Authority, Cairo (Egypt)

    1996-03-01

    The purpose of this paper is to establish the regulatory requirements of that will provide and ensure fire protection of egyptian nuclear facilities. Those facilities that use, handle and store low and/or medium radioactive substances are included. Two or more classes of occupancy are considered to occur in the same building or structure. Fir protection measures and systems were reviewed for three of the egyptian Nuclear facilities. These are egypt first nuclear reactor (ETRR-1) building and systems, hot laboratories buildings and facilities, and the building including the AECL type Is-6500 industrial cobalt-60 gamma irradiator {sup E}gypt`s mega gamma I{sup .} The study includes the outlines of the various aspects of fire protection with a view to define the relevant highlights and scope of egyptian guideline for nuclear installations. The study considers fire protection aspects including the following items: 1- Site selection. 2- General facility design. 3- Fire alarm, detection and suppression systems. (4- Protection for specific areas/control room, cable spreading room, computer room) 5- Fire emergency response planning. 6- Fire water supply. 7- Emergency lighting and communication. 8- Rescue and escape routes. 9- Explosion protection. 10-Manual fire fighting. 11- Security consideration in the interest of fire protection. 12- quality assurance programme. Therefore, first of all the design stage, then during the construction stage, and later during the operation stage, measures must be taken to forestall the risks associated with the outbreak of fire and to ensure that consequences of fire accidents remain limited.

  19. General fire protection guidelines for egyptian nuclear facilities. Vol. 4

    International Nuclear Information System (INIS)

    Radhad, S.; Hussien, A.Z.; Hammad, F.H.

    1996-01-01

    The purpose of this paper is to establish the regulatory requirements of that will provide and ensure fire protection of egyptian nuclear facilities. Those facilities that use, handle and store low and/or medium radioactive substances are included. Two or more classes of occupancy are considered to occur in the same building or structure. Fir protection measures and systems were reviewed for three of the egyptian Nuclear facilities. These are egypt first nuclear reactor (ETRR-1) building and systems, hot laboratories buildings and facilities, and the building including the AECL type Is-6500 industrial cobalt-60 gamma irradiator E gypt's mega gamma I . The study includes the outlines of the various aspects of fire protection with a view to define the relevant highlights and scope of egyptian guideline for nuclear installations. The study considers fire protection aspects including the following items: 1- Site selection. 2- General facility design. 3- Fire alarm, detection and suppression systems. 4- Protection for specific areas/control room, cable spreading room, computer room) 5- Fire emergency response planning. 6- Fire water supply. 7- Emergency lighting and communication. 8- Rescue and escape routes. 9- Explosion protection. 10-Manual fire fighting. 11- Security consideration in the interest of fire protection. 12- quality assurance programme. Therefore, first of all the design stage, then during the construction stage, and later during the operation stage, measures must be taken to forestall the risks associated with the outbreak of fire and to ensure that consequences of fire accidents remain limited

  20. Social impact of accidents

    International Nuclear Information System (INIS)

    Kuroda, Isao

    1997-01-01

    There is the quite big difference between technological risk and social risk feeling. Various biases of social and sensational factors on accidents must be considered to recognize this difference. 'How safe is safe enough' is the perpetual thema concerning with not only technology but also sociology. The safety goal in aircraft design and how making effort to improve the present safety status in civil jet aircrafts is discussed as an example of social risk allowance. INSAG under IAEA started to discuss the safety culture after Chernobyl nuclear power plant accident on 1986. Safety culture and risk communication are the most important procedures to relieve the social impact for accidents. (author)

  1. Severe accident behavior

    International Nuclear Information System (INIS)

    Denning, R.S.

    1986-01-01

    The purpose of this paper is to provide an overview of severe accident behavior. The term source term is defined and a brief history of the regulatory use of source term is presented. The processes in severe accidents in light water reactors are described with particular emphasis on the relationships between accident thermal-hydraulics and chemistry. Those factors which have the greatest impact on predicted source terms are identified. Design differences between plants that affect source term estimation are also described. The principal unresolved issues are identified that are the focus of ongoing research and debate in the technical community

  2. Management of accident risks

    International Nuclear Information System (INIS)

    Compes, P.C.

    1987-01-01

    The example of the Chernobyl accident and the statistics of the occurrence of accidents make clear the threat to humanity, if one cannot guarantee successful accident prevention in the use and distribution of the projects aimed at. The science of safety, as it is known in the Wuppertal model, makes its contribution to this vital task for the human community. It makes it necessary to create the essential dates and concepts, the methods, principles and techniques based on them and the associated instrumentation. (DG) [de

  3. Chernobyl accident and Denmark

    International Nuclear Information System (INIS)

    1986-12-01

    The report describes the Chernobyl accident and its consequences for Denmark in particular. It was commissioned by The Secretary of State for the Environment. The event at the accident site, the release and dispersal of radioactive substances into the atmosphere and over Europe, is described. A discussion of the Danish organisation for nuclear emergencies, how it was activated and adapted to the actual situation, is given. A comprehensive description of the radiological contamination in Denmark following the accident and the estimated health effects, is presented. The situation in other European countries is mentioned. (author)

  4. CERN fire fighters roll out in style

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    On Thursday, 20 October, CERN fire fighters celebrated the arrival of a new equipment transport truck.   Measuring 13m3 and weighing 2.5 tonnes, the truck can carry several types of response materials in the event of chemical or radiological accidents, pollution incidents or floods. It can also pull trailers carrying fire extinguishers and oxygen masks. "Despite its size, this vehicle is extremely practical and flexible, and it can be put to work quickly and easily,” says Patrick Berlinghi, logistics officer for the Fire Brigade. “It is equipped with a rear-view camera and lighting on the rear and the side. It can also be loaded and unloaded very quickly, as it takes only 15 seconds to lower the truck box and open the doors! "  

  5. Radiation dose assessment of ACP hot cell in accident

    International Nuclear Information System (INIS)

    Kook, D. H.; Jeong, W. M.; Koo, J. H.; Jeo, I. J.; Lee, E. P.; Ryu, K. S.

    2003-01-01

    The Advanced spent fuel Condition in Process(ACP) is under development for the effective management of spent fuel which had been generated in nuclear plants. The ACP needs a hot cell where most operations will be performed. To give priority to the environments safety, radiation doses evaluations for the radioactive nuclides in accident cases were preliminarily performed with the meteorological data around facility site. Fire accident prevails over several accidnets. Internal Dose and External Dose evaluation according to short dispersion data for that case show a safe margin for regulation limits and SAR limit of IMEF where this facility will be constructed

  6. Normal accidents living with high-risk technologies

    CERN Document Server

    Perrow, Charles

    1984-01-01

    Normal Accidents analyzes the social side of technological risk. Charles Perrow argues that the conventional engineering approach to ensuring safety--building in more warnings and safeguards--fails because systems complexity makes failures inevitable. He asserts that typical precautions, by adding to complexity, may help create new categories of accidents. (At Chernobyl, tests of a new safety system helped produce the meltdown and subsequent fire.) By recognizing two dimensions of risk--complex versus linear interactions, and tight versus loose coupling--this book provides a powerful framework for analyzing risks and the organizations that insist we run them.

  7. A tale of two fires

    International Nuclear Information System (INIS)

    Swearingen, Gary L.

    2001-01-01

    Timeline and decision response related to the Hanford Site wildfire. Nothing could have been done on-site to prevent the severe fires at two US nuclear facilities last summer. Fires that began outside the boundaries of the Hanford site in Washington and the Los Alamos National Laboratory (LANL) in New Mexico grew and spread into their boundaries and right up to their buildings. Hanford - Washington A vehicle fire resulting from a fatal head-on collision triggered the 24 Command Wildland Fire, which threatened several radioactive waste sites and the Fast Flux Test Facility on the Hanford site. Vegetation on both sides of Washington State Route 24, which runs across the DoE Hanford site, caught fire after a passenger vehicle and semitractor-trailer collided on June 27, 2000. An abundance of natural fuel and adverse weather conditions allowed the fire to move rapidly across the 120-square-mile Fitzner-Eberhardt Arid Lands Ecology Reserve, part of the Hanford Reach National Monument located southwest of the central Hanford site. Unlike the Los Alamos fire (see opposite) the vegetation consisted mainly of cheatgrass, tumbleweed and sage brush. Hot, dry weather had accelerated the fire season in the area, and the National Weather Service had warned that a critical fire weather pattern was ongoing or imminent. From June 27 to July 1 the wildfire burned over nearly 300 square miles, consuming an average of 2000 acres per hour (see panel, opposite). The fire came close to several major radioactive waste sites and blanketed others in a thick layer of smoke. The work of firefighters and the design of the buildings (which have wide concrete and gravel perimeters) kept site facilities safe. However, flames did pass over three inactive waste sites. On June 30 the manager of the DoE Richland Operations Office established a Type B accident investigation board (Board) to address the responses of the DoE and its Hanford site contractors to the fire. Having analysed the event, the

  8. Accident resistant transport container

    Science.gov (United States)

    Anderson, J.A.; Cole, K.K.

    The invention relates to a container for the safe air transport of plutonium having several intermediate wood layers and a load spreader intermediate an inner container and an outer shell for mitigation of shock during a hypothetical accident.

  9. Accident resistant transport container

    International Nuclear Information System (INIS)

    Andersen, J.A.; Cole, J.K.

    1980-01-01

    The invention relates to a container for the safe air transport of plutonium having several intermediate wood layers and a load spreader intermediate an inner container and an outer shell for mitigation of shock during a hypothetical accident

  10. Big nuclear accidents

    International Nuclear Information System (INIS)

    Marshall, W.; Billingon, D.E.; Cameron, R.F.; Curl, S.J.

    1983-09-01

    Much of the debate on the safety of nuclear power focuses on the large number of fatalities that could, in theory, be caused by extremely unlikely but just imaginable reactor accidents. This, along with the nuclear industry's inappropriate use of vocabulary during public debate, has given the general public a distorted impression of the risks of nuclear power. The paper reviews the way in which the probability and consequences of big nuclear accidents have been presented in the past and makes recommendations for the future, including the presentation of the long-term consequences of such accidents in terms of 'loss of life expectancy', 'increased chance of fatal cancer' and 'equivalent pattern of compulsory cigarette smoking'. The paper presents mathematical arguments, which show the derivation and validity of the proposed methods of presenting the consequences of imaginable big nuclear accidents. (author)

  11. Accidents in perspective

    International Nuclear Information System (INIS)

    Gittus, J.H.

    1989-01-01

    The nuclear industry perspective and the public perspective on big nuclear accidents and leukaemia near nuclear sites are discussed. The industry perspective is that big accidents are so unlikely as to be virtually impossible and that leukaemia is not specifically associated with nuclear installations. Clusters of cancer with statistical significance occur in major cities. The public perspective is coloured by a prejudice and myth: the fear of radiation. The big nuclear accident is seen therefore as much more unacceptable than any other big accident. Risks associated with Sizewell-B nuclear station and the liquid gas depot at Canvey Island are discussed. The facts and figures are presented as tables and graphs. Given conflicting interpretations of the leukaemia problem the public inclines towards the more pessimistic view. (author)

  12. Boating Accident Statistics

    Data.gov (United States)

    Department of Homeland Security — Accident statistics available on the Coast Guard’s website by state, year, and one variable to obtain tables and/or graphs. Data from reports has been loaded for...

  13. Impacts of chain accidents in petroleum refineries; Impactos de acidentes em cadeia em refinarias de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Alencar, Joao Rui Barbosa de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE)]|[Laboratorio Farmaceutico do Estado de Pernambuco S/A - LAFEPE, PE (Brazil); Barbosa, Ricardo Augusto P. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil)]|[IESA - Internacional de Engenharia S.A. , Rio de Janeiro, RJ (Brazil); Souza Junior, Mauricio Bezerra de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil)]|[IESA Projetos, Equipamentos e Montagens S.A. , Rio de Janeiro, RJ (Brazil)

    2004-07-01

    The term domino effect denotes a chain of accidents, or situations in which a fire/explosion load generated by an accident in one unit in an industry causes secondary and higher order accidents in other units. Such chains of accidents have a greater propensity to cause damage than stand-alone accidents. This work illustrates the application of models to evaluate the impacts of events with fire and explosion in LPG tanks on other similar units in the park and the possibility of occurrence of a domino effect. The criteria for occurrence of accidents with domino effect adopted in this work, were 37,5 kW/m2 in case of fire radiation and an overpressure of 0,7 atm in explosion cases in a receptor body. The spacing between LPG tanks was evaluated. The results show that such spacing is minimal and doesn't represent, as it should, a parameter indicating a safe distance able to prevent the propagation of an accident with domino effect. (author)

  14. Occupational Accidents And Preventive Measures

    CERN Document Server

    Fassnacht, V

    2006-01-01

    This report presents the 2005 statistics concerning occupational accidents involving members of the CERN personnel and contractors' personnel. It sets out the accident frequency and severity rates and provides a breakdown of accidents by cause and injury. It also contains a summary analysis of the most serious accidents and the associated recommendations.

  15. Accidents with sulfuric acid

    OpenAIRE

    Rajković Miloš B.

    2006-01-01

    Sulfuric acid is an important industrial and strategic raw material, the production of which is developing on all continents, in many factories in the world and with an annual production of over 160 million tons. On the other hand, the production, transport and usage are very dangerous and demand measures of precaution because the consequences could be catastrophic, and not only at the local level where the accident would happen. Accidents that have been publicly recorded during the last eigh...

  16. The Chernobyl accident

    International Nuclear Information System (INIS)

    Berg, J.O.; Christensen, G.; Lingjaerde, R.; Smidt Olsen, H.; Wethe, P.I.

    1986-10-01

    In connection with the Chernobyl accident the report gives a description of the technical features of importance to the accident, the course of events, and the estimated health hazards in the local environment. Dissimilarities in western and Sovjet reactor safety philosophy are dealt with, as well as conceivable concequences in relation to technology and research in western nuclear power programmes. Results of activity level measurements of air and foodstuff, made in Norway by Institute for Energy Technology, are given

  17. Accident analysis of reprocessing

    International Nuclear Information System (INIS)

    Hoermann, E.

    1983-01-01

    The following subjects are studied in detail: Criticality in the dissolver, in HA-column or due to accidental transfer into components of that are not criticality-safe solvent fires in the 1st extraction cycle and 3rd Pu cycle; Red-oil explosions in waste and Pu conditioning; fires of Zy scraps and cans in the head-end; formation of explosive gases by radiolysis. The Zy-fire seems to be the most important risk factor. (orig./HP) [de

  18. Fires, ecological effects of

    Science.gov (United States)

    W. J. Bond; Robert Keane

    2017-01-01

    Fire is both a natural and anthropogenic disturbance influencing the distribution, structure, and functioning of terrestrial ecosystems around the world. Many plants and animals depend on fire for their continued existence. Others species, such as rainforest plants species, are extremely intolerant of burning and need protection from fire. The properties of a fire...

  19. Accident and emergency management

    International Nuclear Information System (INIS)

    Andersen, V.; Moellenbach, K.; Heinonen, R.; Jakobsson, S.; Kukko, T.; Berg, Oe.; Larsen, J.S.; Westgaard, T.; Magnusson, B.; Andersson, H.; Holmstroem, C.; Brehmer, B.; Allard, R.

    1988-06-01

    There is an increasing potential for severe accidents as the industrial development tends towards large, centralised production units. In several industries this has led to the formation of large organisations which are prepared for accidents fighting and for emergency management. The functioning of these organisations critically depends upon efficient decision making and exchange of information. This project is aimed at securing and possibly improving the functionality and efficiency of the accident and emergency management by verifying, demonstrating, and validating the possible use of advanced information technology in the organisations mentioned above. With the nuclear industry in focus the project consists of five main activities: 1) The study and detailed analysis of accident and emergency scenarios based on records from incidents and rills in nuclear installations. 2) Development of a conceptual understanding of accident and emergency management with emphasis on distributed decision making, information flow, and control structure sthat are involved. 3) Development of a general experimental methodology for evaluating the effects of different kinds of decision aids and forms of organisation for emergency management systems with distributed decision making. 4) Development and test of a prototype system for a limited part of an accident and emergency organisation to demonstrate the potential use of computer and communication systems, data-base and knowledge base technology, and applications of expert systems and methods used in artificial intelligence. 5) Production of guidelines for the introduction of advanced information technology in the organisations based on evaluation and validation of the prototype system. (author)

  20. Accident management information needs

    International Nuclear Information System (INIS)

    Hanson, D.J.; Ward, L.W.; Nelson, W.R.; Meyer, O.R.

    1990-04-01

    In support of the US Nuclear Regulatory Commission (NRC) Accident Management Research Program, a methodology has been developed for identifying the plant information needs necessary for personnel involved in the management of an accident to diagnose that an accident is in progress, select and implement strategies to prevent or mitigate the accident, and monitor the effectiveness of these strategies. This report describes the methodology and presents an application of this methodology to a Pressurized Water Reactor (PWR) with a large dry containment. A risk-important severe accident sequence for a PWR is used to examine the capability of the existing measurements to supply the necessary information. The method includes an assessment of the effects of the sequence on the measurement availability including the effects of environmental conditions. The information needs and capabilities identified using this approach are also intended to form the basis for more comprehensive information needs assessment performed during the analyses and development of specific strategies for use in accident management prevention and mitigation. 3 refs., 16 figs., 7 tabs