WorldWideScience

Sample records for suboptimal nonradioprotective doses

  1. Indications for suboptimal low-dose direct oral anticoagulants for non-valvular atrial fibrillation patients

    Directory of Open Access Journals (Sweden)

    Masahiko Umei, MD

    2017-10-01

    Conclusions: With good adherence, the clinical course associated with DOACs is comparatively good. In the future, suboptimal low-dose DOAC therapy may serve as an appropriate choice for some patients with a high risk of stroke and bleeding.

  2. Lansoprazole induces sensitivity to suboptimal doses of paclitaxel in human melanoma.

    Science.gov (United States)

    Azzarito, Tommaso; Venturi, Giulietta; Cesolini, Albino; Fais, Stefano

    2015-01-28

    Tumor acidity is now considered an important determinant of drug-resistance and tumor progression, and anti-acidic approaches, such as Proton Pump inhibitors (PPIs), have demonstrated promising antitumor and chemo-sensitizing efficacy. The main purpose of the present study was to evaluate the possible PPI-induced sensitization of human melanoma cells to Paclitaxel (PTX). Our results show that PTX and the PPI Lansoprazole (LAN) combination was extremely efficient against metastatic melanoma cells, as compared to the single treatments, both in vitro and in vivo. We also showed that acidity plays an important role on the anti-tumor activity of these drugs, being detrimental for PTX activity, while crucial for the synergistic effect of PTX following pretreatment with LAN, due to its nature of pro-drug needing protonation for a full activation. We obtained straightforward results in a human melanoma xenograft model combining well tolerated LAN doses with suboptimal and poorly toxic doses of PTX. With this study we provide a clear evidence that the PPI LAN may be included in new combined therapy of human melanoma together with low doses of PTX. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Bone marrow concentrate promotes bone regeneration with a suboptimal-dose of rhBMP-2.

    Science.gov (United States)

    Egashira, Kazuhiro; Sumita, Yoshinori; Zhong, Weijian; I, Takashi; Ohba, Seigo; Nagai, Kazuhiro; Asahina, Izumi

    2018-01-01

    Bone marrow concentrate (BMC), which is enriched in mononuclear cells (MNCs) and platelets, has recently attracted the attention of clinicians as a new optional means for bone engineering. We previously reported that the osteoinductive effect of bone morphogenetic protein-2 (BMP-2) could be enhanced synergistically by co-transplantation of peripheral blood (PB)-derived platelet-rich plasma (PRP). This study aims to investigate whether BMC can effectively promote bone formation induced by low-dose BMP-2, thereby reducing the undesirable side-effects of BMP-2, compared to PRP. Human BMC was obtained from bone marrow aspirates using an automated blood separator. The BMC was then seeded onto β-TCP granules pre-adsorbed with a suboptimal-dose (minimum concentration to induce bone formation at 2 weeks in mice) of recombinant human (rh) BMP-2. These specimens were transplanted subcutaneously to the dorsal skin of immunodeficient-mice and the induction of ectopic bone formation was assessed 2 and 4 weeks post-transplantation. Transplantations of five other groups [PB, PRP, platelet-poor plasma (PPP), bone marrow aspirate (BM), and BM-PPP] were employed as experimental controls. Then, to clarify the effects on vertical bone augmentation, specimens from the six groups were transplanted for on-lay placement on the craniums of mice. The results indicated that BMC, which contained an approximately 2.5-fold increase in the number of MNCs compared to PRP, could accelerate ectopic bone formation until 2 weeks post-transplantation. On the cranium, the BMC group promoted bone augmentation with a suboptimal-dose of rhBMP-2 compared to other groups. Particularly in the BMC specimens harvested at 4 weeks, we observed newly formed bone surrounding the TCP granules at sites far from the calvarial bone. In conclusion, the addition of BMC could reduce the amount of rhBMP-2 by one-half via its synergistic effect on early-phase osteoinduction. We propose here that BMC transplantation

  4. Suboptimal choice, reward-predictive signals, and temporal information.

    Science.gov (United States)

    Cunningham, Paul J; Shahan, Timothy A

    2018-01-01

    Suboptimal choice refers to preference for an alternative offering a low probability of food (suboptimal alternative) over an alternative offering a higher probability of food (optimal alternative). Numerous studies have found that stimuli signaling probabilistic food play a critical role in the development and maintenance of suboptimal choice. However, there is still much debate about how to characterize how these stimuli influence suboptimal choice. There is substantial evidence that the temporal information conveyed by a food-predictive signal governs its function as both a Pavlovian conditioned stimulus and as an instrumental conditioned reinforcer. Thus, we explore the possibility that food-predictive signals influence suboptimal choice via the temporal information they convey. Application of this temporal information-theoretic approach to suboptimal choice provides a formal, quantitative framework that describes how food-predictive signals influence suboptimal choice in a manner consistent with related phenomena in Pavlovian conditioning and conditioned reinforcement. Our reanalysis of previous data on suboptimal choice suggests that, generally speaking, preference in the suboptimal choice procedure tracks relative temporal information conveyed by food-predictive signals for the suboptimal and optimal alternatives. The model suggests that suboptimal choice develops when the food-predictive signal for the suboptimal alternative conveys more temporal information than that for the optimal alternative. Finally, incorporating a role for competition between temporal information provided by food-predictive signals and relative primary reinforcement rate provides a reasonable account of existing data on suboptimal choice. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  5. Resolving the paradox of suboptimal choice.

    Science.gov (United States)

    Zentall, Thomas R

    2016-01-01

    When humans engage in commercial (totally probabilistic) gambling they are making suboptimal choices because the return is generally less than the investment. This review (a) examines the literature on pigeon suboptimal choice, (b) describes the conditions under which it occurs, (c) identifies the mechanisms that appear to be responsible for the effect, and (d) suggests that similar processes may be able to account for analogous suboptimal choice when humans engage in commercial gambling. Pigeons show suboptimal choice when they choose between 1 alternative that 20% of the time provides them with a signal that they will always get fed or 80% of the time with a signal that they will not get fed (overall 20% reinforcement) and a second alternative that 100% of the time provides them with a signal that they will get fed 50% of the time (overall 50% reinforcement). The pigeons' strong preference for the suboptimal choice was investigated in a series of experiments that found the preference for the suboptimal alternative was determined by the value of the signal that predicted reinforcement, rather its frequency and that the frequency of the signal that predicted nonreinforcement had little effect on the suboptimal choice. Paradoxically, this account makes the prediction that pigeons will be indifferent between an alternative that 50% of the time provides a fully predictive stimulus for reinforcement and an alternative that 100% of the time provides a fully predictive stimulus for reinforcement. The similarities and differences of this suboptimal choice task to human gambling are discussed. (c) 2016 APA, all rights reserved).

  6. Investigating the prevalence, predictors, and prognosis of suboptimal statin use early after a non-ST elevation acute coronary syndrome.

    Science.gov (United States)

    Turner, Richard M; Yin, Peng; Hanson, Anita; FitzGerald, Richard; Morris, Andrew P; Stables, Rod H; Jorgensen, Andrea L; Pirmohamed, Munir

    High-potency statin therapy is recommended in the secondary prevention of cardiovascular disease but discontinuation, dose reduction, statin switching, and/or nonadherence occur in practice. To determine the prevalence and predictors of deviation from high-potency statin use early after a non-ST elevation acute coronary syndrome (NSTE-ACS) and its association with subsequent major adverse cardiovascular events (MACE) and all-cause mortality (ACM). A total of 1005 patients from a UK-based prospective NSTE-ACS cohort study discharged on high-potency statin therapy (atorvastatin 80 mg, rosuvastatin 20 mg, or 40 mg daily) were included. At 1 month, patients were divided into constant high-potency statin users, and suboptimal users incorporating statin discontinuation, dose reduction, switching statin to a lower equivalent potency, and/or statin nonadherence. Follow-up was a median of 16 months. There were 156 suboptimal (∼15.5%) and 849 constant statin users. Factors associated in multivariable analysis with suboptimal statin occurrence included female sex (odds ratio 1.75, 95% confidence interval [CI] 1.14-2.68) and muscular symptoms (odds ratio 4.28, 95% CI 1.30-14.08). Suboptimal statin use was associated with increased adjusted risks of time to MACE (hazard ratio 2.10, 95% CI 1.25-3.53, P = .005) and ACM (hazard ratio 2.46, 95% CI 1.38-4.39, P = .003). Subgroup analysis confirmed that the increased MACE/ACM risks were principally attributable to statin discontinuation or nonadherence. Conversion to suboptimal statin use is common early after NSTE-ACS and is partly related to muscular symptoms. Statin discontinuation or non-adherence carries an adverse prognosis. Interventions that preserve and enhance statin utilization could improve post NSTE-ACS outcomes. Copyright © 2017 National Lipid Association. Published by Elsevier Inc. All rights reserved.

  7. Real-World Dosing Patterns of Atomoxetine in Adults with Attention-Deficit/Hyperactivity Disorder.

    Science.gov (United States)

    Kabul, Samaneh; Alatorre, Carlos; Montejano, Leslie B; Farr, Amanda M; Clemow, David B

    2015-12-01

    The aim was to investigate the dosing patterns of atomoxetine monotherapy in adult patients with attention-deficit/hyperactivity disorder (ADHD) in a retrospective analysis. Adult (≥ 18 years) patients with ADHD newly initiated on atomoxetine with ≥ 1 outpatient pharmacy claim for atomoxetine between January 2006 and December 2011 were selected from the Truven Health MarketScan(®) Commercial database. After a 30-day titration period, dosing patterns of atomoxetine monotherapy were analyzed in the 12 months following initiation. In addition, patient demographic and clinical characteristics were compared to identify characteristics associated with suboptimal versus recommended dosing. Of the 12,412 adult patients with ADHD newly initiated on atomoxetine, 4548 (36.6%) were suboptimally dosed, whereas 3323 (26.7%) were treated at recommended dose. Overall, study patients were treated at a mean (standard deviation [SD]) dose of 68.5 (44.9) mg/day. The suboptimal dosing cohort included significantly more females (54% vs. 44%, P atomoxetine therapy in a real-world setting are often dosed suboptimally. Increasing the awareness on optimal dosing strategy among clinicians and patients is warranted to maximize the therapeutic benefits of atomoxetine among adult patients with ADHD. © 2015 Eli Lilly and Company. CNS Neuroscience and Therapeutics published by John Wiley & Sons Ltd.

  8. Design considerations for a suboptimal Kalman filter

    Science.gov (United States)

    Difilippo, D. J.

    1995-06-01

    In designing a suboptimal Kalman filter, the designer must decide how to simplify the system error model without causing the filter estimation errors to increase to unacceptable levels. Deletion of certain error states and decoupling of error state dynamics are the two principal model simplifications that are commonly used in suboptimal filter design. For the most part, the decisions as to which error states can be deleted or decoupled are based on the designer's understanding of the physics of the particular system. Consequently, the details of a suboptimal design are usually unique to the specific application. In this paper, the process of designing a suboptimal Kalman filter is illustrated for the case of an airborne transfer-of-alignment (TOA) system used for synthetic aperture radar (SAR) motion compensation. In this application, the filter must continuously transfer the alignment of an onboard Doppler-damped master inertial navigation system (INS) to a strapdown navigator that processes information from a less accurate inertial measurement unit (IMU) mounted on the radar antenna. The IMU is used to measure spurious antenna motion during the SAR imaging interval, so that compensating phase corrections can be computed and applied to the radar returns, thereby presenting image degradation that would otherwise result from such motions. The principles of SAR are described in many references, for instance. The primary function of the TOA Kalman filter in a SAR motion compensation system is to control strapdown navigator attitude errors, and to a less degree, velocity and heading errors. Unlike a classical navigation application, absolute positional accuracy is not important. The motion compensation requirements for SAR imaging are discussed in some detail. This TOA application is particularly appropriate as a vehicle for discussing suboptimal filter design, because the system contains features that can be exploited to allow both deletion and decoupling of error

  9. Suboptimal palliative sedation in primary care: an exploration.

    Science.gov (United States)

    Pype, Peter; Teuwen, Inge; Mertens, Fien; Sercu, Marij; De Sutter, An

    2018-02-01

    Palliative sedation is a therapeutic option to control refractory symptoms in terminal palliative patients. This study aims at describing the occurrence and characteristics of suboptimal palliative sedations in primary care and at exploring the way general practitioners (GPs) experience suboptimal palliative sedation in their practice. We conducted a mixed methods study with a quantitative prospective survey in primary care and qualitative semi-structured interviews with GPs. The research team defined suboptimal palliative sedation as a time interval until deep sleep >1.5 h and/ or >2 awakenings after the start of the unconsciousness. Descriptive statistics were calculated on the quantitative data. Thematic analysis was used to analyse interview transcripts. We registered 63 palliative sedations in 1181 home deaths, 27 forms were completed. Eleven palliative sedations were suboptimal: eight due to the long time span until deep sleep; three due the number of unintended awakenings. GPs' interview analysis revealed two major themes: the shifting perception of failure and the burden of responsibility. Suboptimal palliative sedation occurs frequently in primary palliative care. Efficient communication towards family members is needed to prevent them from having unrealistic expectations and to prevent putting pressure on the GP to hasten the procedure. Sharing the burden of decision-making during the procedure with other health care professionals might diminish the heavy responsibility as perceived by GPs.

  10. How suboptimal are linear sharing rules?

    DEFF Research Database (Denmark)

    Jensen, Bjarne Astrup; Nielsen, Jørgen Aase

    2016-01-01

    that significant losses can arise when investors are diverse in their risk attitude. We also show that an investor with a low degree of risk aversion, like the logarithmic or the square root investor, often applied in portfolio choice models, can either inflict or be subject to severe losses when being forced...... two sources of suboptimal investment decisions as seen from each of the two investors individually. One is the suboptimal choice of portfolio, the other is the forced linear sharing rule. We measure the combined consequence for each investor by their respective loss in wealth equivalent. We show...

  11. On the Origins of Suboptimality in Human Probabilistic Inference

    Science.gov (United States)

    Acerbi, Luigi; Vijayakumar, Sethu; Wolpert, Daniel M.

    2014-01-01

    Humans have been shown to combine noisy sensory information with previous experience (priors), in qualitative and sometimes quantitative agreement with the statistically-optimal predictions of Bayesian integration. However, when the prior distribution becomes more complex than a simple Gaussian, such as skewed or bimodal, training takes much longer and performance appears suboptimal. It is unclear whether such suboptimality arises from an imprecise internal representation of the complex prior, or from additional constraints in performing probabilistic computations on complex distributions, even when accurately represented. Here we probe the sources of suboptimality in probabilistic inference using a novel estimation task in which subjects are exposed to an explicitly provided distribution, thereby removing the need to remember the prior. Subjects had to estimate the location of a target given a noisy cue and a visual representation of the prior probability density over locations, which changed on each trial. Different classes of priors were examined (Gaussian, unimodal, bimodal). Subjects' performance was in qualitative agreement with the predictions of Bayesian Decision Theory although generally suboptimal. The degree of suboptimality was modulated by statistical features of the priors but was largely independent of the class of the prior and level of noise in the cue, suggesting that suboptimality in dealing with complex statistical features, such as bimodality, may be due to a problem of acquiring the priors rather than computing with them. We performed a factorial model comparison across a large set of Bayesian observer models to identify additional sources of noise and suboptimality. Our analysis rejects several models of stochastic behavior, including probability matching and sample-averaging strategies. Instead we show that subjects' response variability was mainly driven by a combination of a noisy estimation of the parameters of the priors, and by

  12. On the origins of suboptimality in human probabilistic inference.

    Directory of Open Access Journals (Sweden)

    Luigi Acerbi

    2014-06-01

    Full Text Available Humans have been shown to combine noisy sensory information with previous experience (priors, in qualitative and sometimes quantitative agreement with the statistically-optimal predictions of Bayesian integration. However, when the prior distribution becomes more complex than a simple Gaussian, such as skewed or bimodal, training takes much longer and performance appears suboptimal. It is unclear whether such suboptimality arises from an imprecise internal representation of the complex prior, or from additional constraints in performing probabilistic computations on complex distributions, even when accurately represented. Here we probe the sources of suboptimality in probabilistic inference using a novel estimation task in which subjects are exposed to an explicitly provided distribution, thereby removing the need to remember the prior. Subjects had to estimate the location of a target given a noisy cue and a visual representation of the prior probability density over locations, which changed on each trial. Different classes of priors were examined (Gaussian, unimodal, bimodal. Subjects' performance was in qualitative agreement with the predictions of Bayesian Decision Theory although generally suboptimal. The degree of suboptimality was modulated by statistical features of the priors but was largely independent of the class of the prior and level of noise in the cue, suggesting that suboptimality in dealing with complex statistical features, such as bimodality, may be due to a problem of acquiring the priors rather than computing with them. We performed a factorial model comparison across a large set of Bayesian observer models to identify additional sources of noise and suboptimality. Our analysis rejects several models of stochastic behavior, including probability matching and sample-averaging strategies. Instead we show that subjects' response variability was mainly driven by a combination of a noisy estimation of the parameters of the

  13. Effects of an amylopectin and chromium complex on the anabolic response to a suboptimal dose of whey protein.

    Science.gov (United States)

    Ziegenfuss, T N; Lopez, H L; Kedia, A; Habowski, S M; Sandrock, J E; Raub, B; Kerksick, C M; Ferrando, A A

    2017-01-01

    Previous research has demonstrated the permissive effect of insulin on muscle protein kinetics, and the enhanced insulin sensitizing effect of chromium. In the presence of adequate whole protein and/or essential amino acids (EAA), insulin has a stimulatory effect on muscle protein synthesis, whereas in conditions of lower blood EAA concentrations, insulin has an inhibitory effect on protein breakdown. In this study, we determined the effect of an amylopectin/chromium (ACr) complex on changes in plasma concentrations of EAA, insulin, glucose, and the fractional rate of muscle protein synthesis (FSR). Using a double-blind, cross-over design, ten subjects (six men, four women) consumed 6 g whey protein + 2 g of the amylopectin-chromium complex (WPACr) or 6 g whey protein (WP) after an overnight fast. FSR was measured using a primed, continuous infusion of ring-d 5 -phenylalanine with serial muscle biopsies performed at 2, 4, and 8 h. Plasma EAA and insulin were assayed by ion-exchange chromatography and ELISA, respectively. After the biopsy at 4 h, subjects ingested their respective supplement, completed eight sets of bilateral isotonic leg extensions at 80% of their estimated 1-RM, and a final biopsy was obtained 4 h later. Both trials increased EAA similarly, with peak levels noted 30 min after ingestion. Insulin tended ( p  = 0.09) to be higher in the WPACr trial. Paired samples t-tests using baseline and 4-h post-ingestion FSR data separately for each group revealed significant increases in the WPACr group (+0.0197%/h, p  = 0.0004) and no difference in the WP group (+0.01215%/hr, p  = 0.23). Independent t-tests confirmed significant ( p  = 0.045) differences in post-treatment FSR between trials. These data indicate that the addition of ACr to a 6 g dose of whey protein (WPACr) increases the FSR response beyond what is seen with a suboptimal dose of whey protein alone.

  14. Optimal medication dosing from suboptimal clinical examples: a deep reinforcement learning approach.

    Science.gov (United States)

    Nemati, Shamim; Ghassemi, Mohammad M; Clifford, Gari D

    2016-08-01

    Misdosing medications with sensitive therapeutic windows, such as heparin, can place patients at unnecessary risk, increase length of hospital stay, and lead to wasted hospital resources. In this work, we present a clinician-in-the-loop sequential decision making framework, which provides an individualized dosing policy adapted to each patient's evolving clinical phenotype. We employed retrospective data from the publicly available MIMIC II intensive care unit database, and developed a deep reinforcement learning algorithm that learns an optimal heparin dosing policy from sample dosing trails and their associated outcomes in large electronic medical records. Using separate training and testing datasets, our model was observed to be effective in proposing heparin doses that resulted in better expected outcomes than the clinical guidelines. Our results demonstrate that a sequential modeling approach, learned from retrospective data, could potentially be used at the bedside to derive individualized patient dosing policies.

  15. Effect of different seed treatments on maize seed germination parameters under optimal and suboptimal temperature conditions

    Directory of Open Access Journals (Sweden)

    Vujošević Bojana

    2017-01-01

    Full Text Available The aim of this study was to determine the effect of different seed treatments on germination parameters of three maize genotypes under optimal and suboptimal temperature conditions. Seed was treated with recommended doses of three commercial pesticide formulations: metalaxyl-m 10 g/L + fludioxonil 25 g/L, metalaxyl 20 g/kg + prothioconazole 100 g/kg and thiacloprid 400 g/L. Testing was conducted at 25°C and 15°C. Results of the study indicate that there are differences in response of maize genotypes to applied seed treatments, as well as to a specific treatment at optimal and suboptimal temperatures. Some treatments, depending on the mixing partner and temperature conditions, can affect final germination. In other cases, germination rate can be accelerated or prolonged, but with no effect on final germination. In order to provide fast and uniform emergence under different temperature conditions, further examination of the response of maize genotypes to specific seed treatments would be beneficial.

  16. Ultimate explanations and suboptimal choice.

    Science.gov (United States)

    Vasconcelos, Marco; Machado, Armando; Pandeirada, Josefa N S

    2018-07-01

    Researchers have unraveled multiple cases in which behavior deviates from rationality principles. We propose that such deviations are valuable tools to understand the adaptive significance of the underpinning mechanisms. To illustrate, we discuss in detail an experimental protocol in which animals systematically incur substantial foraging losses by preferring a lean but informative option over a rich but non-informative one. To understand how adaptive mechanisms may fail to maximize food intake, we review a model inspired by optimal foraging principles that reconciles sub-optimal choice with the view that current behavioral mechanisms were pruned by the optimizing action of natural selection. To move beyond retrospective speculation, we then review critical tests of the model, regarding both its assumptions and its (sometimes counterintuitive) predictions, all of which have been upheld. The overall contention is that (a) known mechanisms can be used to develop better ultimate accounts and that (b) to understand why mechanisms that generate suboptimal behavior evolved, we need to consider their adaptive value in the animal's characteristic ecology. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Suboptimal control for drag reduction in turbulent pipe flow

    International Nuclear Information System (INIS)

    Choi, Jung Il; Sung, Hyung Jin; Xu, Chun Xiao

    2001-01-01

    A suboptimal control law in turbulent pipe flow is derived and tested. Two sensing variables ∂ρ/∂θ / w and ∂ν θ /∂r / w are applied with two actuations φ θ and φ γ . To test the suboptimal control law, direct numerical simulations of turbulent pipe flow at Re τ =150 are performed. When the control law is applied, a 13∼23% drag reduction is achieved. The most effective drag reduction is made at the pair of ∂υ θ /∂r / w and φ γ . An impenetrable virtual wall concept is useful for analyzing the near-wall suction and blowing. The virtual wall concept is useful for analyzing the near-wall behavior of the controlled flow. Comparison of the present suboptimal control with that of turbulent channel flow reveals that the curvature effect is insignificant

  18. Suboptimal maternal and paternal mental health are associated with child bullying perpetration.

    Science.gov (United States)

    Shetgiri, Rashmi; Lin, Hua; Flores, Glenn

    2015-06-01

    This study examines associations between maternal and paternal mental health and child bullying perpetration among school-age children, and whether having one or both parents with suboptimal mental health is associated with bullying. The 2007 National Survey of Children's Health, a nationally-representative, random-digit-dial survey, was analyzed, using a parent-reported bullying measure. Suboptimal mental health was defined as fair/poor (vs. good/very good/excellent) parental self-reported mental and emotional health. Of the 61,613 parents surveyed, more than half were parents of boys and were white, 20% were Latino, 15% African American, and 7% other race/ethnicity. Suboptimal maternal (OR 1.4; 95% CI 1.1-1.8) and paternal (OR 1.5; 95% CI 1.1-2.2) mental health are associated with bullying. Compared with children with no parents with suboptimal mental health, children with only one or both parents with suboptimal mental health have higher bullying odds. Addressing the mental health of both parents may prove beneficial in preventing bullying.

  19. Suboptimal performance on neuropsychological tests in patients with suspected chronic toxic encephalopathy

    NARCIS (Netherlands)

    van Hout, Moniek S. E.; Schmand, Ben; Wekking, Ellie M.; Hageman, Gerard; Deelman, Betto G.

    2003-01-01

    Suboptimal performance during neuropsychological testing can seriously complicate assessment in behavioral neurotoxicology. We present data on the prevalence of suboptimal performance in a group of Dutch patients with suspected chronic toxic encephalopathy (CTE) after long-term occupational exposure

  20. Suboptimal performance on neuropsychological tests in patients with suspected chronic toxic encephalopathy

    NARCIS (Netherlands)

    van Hout, MSE; Schmand, B; Wekking, EM; Hageman, G; Deelman, BG

    Suboptimal performance during neuropsychological testing can seriously complicate assessment in behavioral neurotoxicology. We present data on the prevalence of suboptimal performance in a group of Dutch patients with suspected chronic toxic encephalopathy (CTE) after long-term occupational exposure

  1. Frequency and predictors of suboptimal glycemic control in an African diabetic population

    Directory of Open Access Journals (Sweden)

    Kibirige D

    2017-02-01

    Full Text Available Davis Kibirige,1 George Patrick Akabwai,2 Leaticia Kampiire,3 Daniel Ssekikubo Kiggundu,4 William Lumu5 1Department of Medicine/Diabetic and Hypertension Clinics, Our Lady of Consolota Hospital, Kisubi, 2Baylor College of Medicine, Children’s Foundation, 3Infectious Diseases Research Collaboration, Kampala, 4Nephrology Unit, Mulago National Referral and Teaching Hospital, Kampala, 5Department of Medicine and Diabetes/Endocrine Unit, Mengo Hospital, Mengo, Uganda Background: Persistent suboptimal glycemic control is invariably associated with onset and progression of acute and chronic diabetic complications in diabetic patients. In Uganda, studies documenting the magnitude and predictors of suboptimal glycemic control in adult ambulatory diabetic patients are limited. This study aimed at determining the frequency and predictors of suboptimal glycemic control in adult diabetic patients attending three urban outpatient diabetic clinics in Uganda. Methods: In this hospital-based cross-sectional study, eligible ambulatory adult diabetic patients attending outpatient diabetic clinics of three urban hospitals were consecutively enrolled over 11 months. Suboptimal glycemic control was defined as glycated hemoglobin (HbA1c level ≥7%. Multivariable analysis was applied to determine the predictors. Results: The mean age of the study participants was 52.2±14.4 years, and the majority of them were females (283, 66.9%. The median (interquartile range HbA1c level was 9% (6.8%–12.4%. Suboptimal glycemic control was noted in 311 study participants, accounting for 73.52% of the participants. HbA1c levels of 7%–8%, 8.1%–9.9%, and ≥10% were noted in 56 (13.24%, 76 (17.97%, and 179 (42.32% study participants, respectively. The documented predictors of suboptimal glycemic control were metformin monotherapy (odds ratio: 0.36, 95% confidence interval: 0.21–0.63, p<0.005 and insulin therapy (odds ratio: 2.41, 95% confidence interval: 1.41–4.12, p=0

  2. Cost-effectiveness of extended-release methylphenidate in children and adolescents with attention-deficit/hyperactivity disorder sub-optimally treated with immediate release methylphenidate.

    Directory of Open Access Journals (Sweden)

    Jurjen van der Schans

    Full Text Available Attention-Deficit/Hyperactivity Disorder (ADHD is a common psychiatric disorder in children and adolescents. Immediate-release methylphenidate (IR-MPH is the medical treatment of first choice. The necessity to use several IR-MPH tablets per day and associated potential social stigma at school often leads to reduced compliance, sub-optimal treatment, and therefore economic loss. Replacement of IR-MPH with a single-dose extended release (ER-MPH formulation may improve drug response and economic efficiency.To evaluate the cost-effectiveness from a societal perspective of a switch from IR-MPH to ER-MPH in patients who are sub-optimally treated.A daily Markov-cycle model covering a time-span of 10 years was developed including four different health states: (1 optimal response, (2 sub-optimal response, (3 discontinued treatment, and (4 natural remission. ER-MPH options included methylphenidate osmotic release oral system (MPH-OROS and Equasym XL/Medikinet CR. Both direct costs and indirect costs were included in the analysis, and effects were expressed as quality-adjusted life years (QALYs. Univariate, multivariate as well as probabilistic sensitivity analysis were conducted and the main outcomes were incremental cost-effectiveness ratios.Switching sub-optimally treated patients from IR-MPH to MPH-OROS or Equasym XL/Medikinet CR led to per-patient cost-savings of €4200 and €5400, respectively, over a 10-year treatment span. Sensitivity analysis with plausible variations of input parameters resulted in cost-savings in the vast majority of estimations.This study lends economic support to switching patients with ADHD with suboptimal response to short-acting IR-MPH to long-acting ER-MPH regimens.

  3. Continual reassessment method for dose escalation clinical trials in oncology: a comparison of prior skeleton approaches using AZD3514 data.

    Science.gov (United States)

    James, Gareth D; Symeonides, Stefan N; Marshall, Jayne; Young, Julia; Clack, Glen

    2016-08-31

    The continual reassessment method (CRM) requires an underlying model of the dose-toxicity relationship ("prior skeleton") and there is limited guidance of what this should be when little is known about this association. In this manuscript the impact of applying the CRM with different prior skeleton approaches and the 3 + 3 method are compared in terms of ability to determine the true maximum tolerated dose (MTD) and number of patients allocated to sub-optimal and toxic doses. Post-hoc dose-escalation analyses on real-life clinical trial data on an early oncology compound (AZD3514), using the 3 + 3 method and CRM using six different prior skeleton approaches. All methods correctly identified the true MTD. The 3 + 3 method allocated six patients to both sub-optimal and toxic doses. All CRM approaches allocated four patients to sub-optimal doses. No patients were allocated to toxic doses from sigmoidal, two from conservative and five from other approaches. Prior skeletons for the CRM for phase 1 clinical trials are proposed in this manuscript and applied to a real clinical trial dataset. Highly accurate initial skeleton estimates may not be essential to determine the true MTD, and, as expected, all CRM methods out-performed the 3 + 3 method. There were differences in performance between skeletons. The choice of skeleton should depend on whether minimizing the number of patients allocated to suboptimal or toxic doses is more important. NCT01162395 , Trial date of first registration: July 13, 2010.

  4. Prevalence and Determinants of Suboptimal Vitamin D Levels in a Multiethnic Asian Population.

    Science.gov (United States)

    Man, Ryan Eyn Kidd; Li, Ling-Jun; Cheng, Ching-Yu; Wong, Tien Yin; Lamoureux, Ecosse; Sabanayagam, Charumathi

    2017-03-22

    This population-based cross-sectional study examined the prevalence and risk factors of suboptimal vitamin D levels (assessed using circulating 25-hydroxycholecalciferol (25(OH)D)) in a multi-ethnic sample of Asian adults. Plasma 25(OH)D concentration of 1139 Chinese, Malay and Indians (40-80 years) were stratified into normal (≥30 ng/mL), and suboptimal (including insufficiency and deficiency, 65 years), Malay and Indian ethnicities (compared to Chinese ethnicity), and higher body mass index, HbA1c, education and income levels were associated with suboptimal 25(OH)D concentration ( p < 0.05). In a population-based sample of Asian adults, approximately 75% had suboptimal 25(OH)D concentration. Targeted interventions and stricter reinforcements of existing guidelines for vitamin D supplementation are needed for groups at risk of vitamin D insufficiency/deficiency.

  5. Socioeconomic factors explain suboptimal adherence to antiretroviral therapy among HIV-infected Australian adults with viral suppression.

    Directory of Open Access Journals (Sweden)

    Krista J Siefried

    Full Text Available Missing more than one tablet of contemporary antiretroviral therapy (ART per month increases the risk of virological failure. Recent studies evaluating a comprehensive range of potential risk factors for suboptimal adherence are not available for high-income settings.Adults on ART with undetectable viral load (UDVL were recruited into a national, multi-centre cohort, completing a comprehensive survey assessing demographics, socio-economic indicators, physical health, well-being, life stressors, social supports, HIV disclosure, HIV-related stigma and discrimination, healthcare access, ART regimen, adherence, side effects, costs and treatment beliefs. Baseline data were assessed, and suboptimal adherence was defined as self-reported missing ≥1 ART dose/month over the previous 3-months; associated factors were identified using bivariate and multivariate binary logistic regression.We assessed 522 participants (494 [94.5%] men, mean age = 50.8 years, median duration UDVL = 3.3 years [IQR = 1.2-6.8] at 17 sexual health, hospital, and general practice clinics across Australia. Seventy-eight participants (14.9% reported missing ≥1 dose/month over the previous three months, which was independently associated with: being Australian-born (AOR [adjusted odds ratio] = 2.4 [95%CI = 1.2-4.9], p = 0.014, not being in a relationship (AOR = 3.3 [95%CI = 1.5-7.3], p = 0.004, reaching the "Medicare safety net" (capping annual medical/pharmaceutical costs (AOR = 2.2 [95%CI = 1.1-4.5], p = 0.024, living in subsidised housing (AOR = 2.5 [95%CI = 1.0-6.2], p = 0.045, receiving home-care services (AOR = 4.4 [95%CI = 1.0-18.8], p = 0.046, HIV community/outreach services linkage (AOR = 2.4 [95%CI = 1.1-5.4], p = 0.033, and starting ART following self-request (AOR = 3.0 [95%CI = 1.3-7.0], p = 0.012.In this population, 15% reported recent suboptimal ART adherence at levels associated in prospective studies with subsequent virological failure, despite all having an

  6. Action-Dependent Photobiomodulation on Health, Suboptimal Health, and Disease

    Directory of Open Access Journals (Sweden)

    Timon Cheng-Yi Liu

    2014-01-01

    Full Text Available The global photobiomodulation (PBM on an organism was studied in terms of function-specific homeostasis (FSH and scale-free functional network in this paper. A function can be classified into a normal function in its FSH and a dysfunctional function far from its FSH. An FSH-specific stress (FSS disrupting an FSH can also be classified into a successful stress in its FSS-specific homeostasis (FSSH and a chronic stress far from its FSSH. The internal functions of an organism can be divided into essential, special nonessential, and general nonessential functions. Health may be defined as a state of an organism in which all the essential and special nonessential functions are normal or their stresses are successful. Suboptimal health may be defined as a state of a disease-free organism in which only some special nonessential functions are dysfunctional in comparison with its healthy state. Disease may be defined as a state of an organism which is not in both health and suboptimal health. The global PBM of health, suboptimal health, or disease suggested that the PBM may depend on the organism action.

  7. Conversion coefficients for determining organ doses in paediatric spine radiography

    Energy Technology Data Exchange (ETDEWEB)

    Seidenbusch, Michael; Schneider, Karl [Ludwig-Maximilians-University of Munich, Institute of Clinical Radiology - Paediatric Radiology, Muenchen (Germany)

    2014-04-15

    Knowledge of organ and effective doses achieved during paediatric x-ray examinations is an important prerequisite for assessment of radiation burden to the patient. Conversion coefficients for reconstruction of organ and effective doses from entrance doses for segmental spine radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission. Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional segmental spine radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation field settings. Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during cervical, thoracic and lumbar spine radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal and lateral beam projections and the standard focus detector distance of 115 cm. The conversion coefficients presented may be used for organ dose assessments from entrance doses measured during spine radiographs of patients of all age groups and all field settings within the optimal and suboptimal standard field settings. (orig.)

  8. Exogenous recombinant human growth hormone effects during suboptimal energy and zinc intake

    Directory of Open Access Journals (Sweden)

    Duro Debora

    2005-04-01

    Full Text Available Abstract Background Energy and Zinc (Zn deficiencies have been associated with nutritional related growth retardation as well as growth hormone (GH resistance. In this study, the relationship between suboptimal energy and/or Zn intake and growth in rats and their response to immunoreactive exogenous recombinant human GH (GHi, was determined. Results Rats treated with GHi and fed ad-libitum energy and Zn (100/100 had increased IGFBP-3 (p Conclusion These results suggest that GHi enhances weight gain in rats with suboptimal energy and Zn intake but does not modify energy expenditure or physical activity index. Suboptimal Zn intake did not exacerbate the reduced growth or decrease in energy expenditure observed with energy restriction.

  9. Sacral Nerve Stimulation for Constipation: Suboptimal Outcome and Adverse Events

    DEFF Research Database (Denmark)

    Maeda, Yasuko; Lundby, Lilli; Buntzen, Steen

    2010-01-01

    Sacral nerve stimulation is an emerging treatment for patients with severe constipation. There has been no substantial report to date on suboptimal outcomes and complications. We report our experience of more than 6 years by focusing on incidents and the management of reportable events.......Sacral nerve stimulation is an emerging treatment for patients with severe constipation. There has been no substantial report to date on suboptimal outcomes and complications. We report our experience of more than 6 years by focusing on incidents and the management of reportable events....

  10. Gibberellin Is Involved in Inhibition of Cucumber Growth and Nitrogen Uptake at Suboptimal Root-Zone Temperatures.

    Directory of Open Access Journals (Sweden)

    Longqiang Bai

    Full Text Available Suboptimal temperature stress often causes heavy yield losses of vegetables by suppressing plant growth during winter and early spring. Gibberellin acid (GA has been reported to be involved in plant growth and acquisition of mineral nutrients. However, no studies have evaluated the role of GA in the regulation of growth and nutrient acquisition by vegetables under conditions of suboptimal temperatures in greenhouse. Here, we investigated the roles of GA in the regulation of growth and nitrate acquisition of cucumber (Cucumis sativus L. plants under conditions of short-term suboptimal root-zone temperatures (Tr. Exposure of cucumber seedlings to a Tr of 16°C led to a significant reduction in root growth, and this inhibitory effect was reversed by exogenous application of GA. Expression patterns of several genes encoding key enzymes in GA metabolism were altered by suboptimal Tr treatment, and endogenous GA concentrations in cucumber roots were significantly reduced by exposure of cucumber plants to 16°C Tr, suggesting that inhibition of root growth by suboptimal Tr may result from disruption of endogenous GA homeostasis. To further explore the mechanism underlying the GA-dependent cucumber growth under suboptimal Tr, we studied the effect of suboptimal Tr and GA on nitrate uptake, and found that exposure of cucumber seedlings to 16°C Tr led to a significant reduction in nitrate uptake rate, and exogenous application GA can alleviate the down-regulation by up regulating the expression of genes associated with nitrate uptake. Finally, we demonstrated that N accumulation in cucumber seedlings under suboptimal Tr conditions was improved by exogenous application of GA due probably to both enhanced root growth and nitrate absorption activity. These results indicate that a reduction in endogenous GA concentrations in roots due to down-regulation of GA biosynthesis at transcriptional level may be a key event to underpin the suboptimal Tr

  11. Sub-optimal birth weight in newborns of a high socioeconomic status population

    Directory of Open Access Journals (Sweden)

    Conceição Aparecida de Mattos Segre

    2008-09-01

    Full Text Available Objective: To compare sub-optimal birth weight (2,500 to 2,999 g term newborns to appropriate for gestational age (birth weight ≥ 3,000 g term newborns, regarding maternal data and newborn morbidity and mortality. Methods: Single term newborns, appropriate for gestational age from a high socioeconomic population (n = 1,242 with birth weight ranging from 2,500 to 2,999 g (Group I were compared to 4,907 newborns with birth weight ≥ than 3,000 g (Group II. Maternal and newborn characteristics were compared between the groups. The Mann-Whitney test, χ2 test and multivariate analysis were used. The significance level adopted was p < 0.05. Rresults: The frequency of sub-optimal birth weight newborns in the population studied was 20.2%. There was a significant association between sub-optimal birth weight and maternal weight before pregnancy and body mass index, maternal weight gain, height, smoking habit and hypertension. Newborns’ 1-minute Apgar score, neonatal hypoglycemia, jaundice, transient tachypnea, congenital pneumonia and hospital stay were significantly different between the groups (p < 0.05. A significant relationship could not be established with the 5-minute Apgar score and pulmonary hypertension in both groups. Neonatal mortality did not differ between the groups. Cconclusions: Socioeconomic status was not a risk factor for sub-optimal birth weight in the studied population. Genetic and environmental factors were associated to sub-optimal weight and neonatal diseases. According to these data, this group of newborns should receive special attention from the health team.

  12. Nomogram for suboptimal cytoreduction at primary surgery for advanced stage ovarian cancer.

    Science.gov (United States)

    Gerestein, Cornelis G; Eijkemans, Marinus J; Bakker, Jeanette; Elgersma, Otto E; van der Burg, Maria E L; Kooi, Geertruida S; Burger, Curt W

    2011-11-01

    Maximal cytoreduction to minimal residual tumor is the most important determinant of prognosis in patients with advanced stage epithelial ovarian cancer (EOC). Preoperative prediction of suboptimal cytoreduction, defined as residual tumor >1 cm, could guide treatment decisions and improve counseling. The objective of this study was to identify predictive computed tomographic (CT) scan and clinical parameters for suboptimal cytoreduction at primary cytoreductive surgery for advanced stage EOC and to generate a nomogram with the identified parameters, which would be easy to use in daily clinical practice. Between October 2005 and December 2008, all patients with primary surgery for suspected advanced stage EOC at six participating teaching hospitals in the South Western part of the Netherlands entered the study protocol. To investigate independent predictors of suboptimal cytoreduction, a Cox proportional hazard model with backward stepwise elimination was utilized. One hundred and fifteen patients with FIGO stage III/IV EOC entered the study protocol. Optimal cytoreduction was achieved in 52 (45%) patients. A suboptimal cytoreduction was predicted by preoperative blood platelet count (p=0.1990; odds ratio (OR)=1.002), diffuse peritoneal thickening (DPT) (p=0.0074; OR=3.021), and presence of ascites on at least two thirds of CT scan slices (p=0.0385; OR=2.294) with a for-optimism corrected c-statistic of 0.67. Suboptimal cytoreduction was predicted by preoperative platelet count, DPT and presence of ascites. The generated nomogram can, after external validation, be used to estimate surgical outcome and to identify those patients, who might benefit from alternative treatment approaches.

  13. Suboptimal investments and M&A deals in emerging capital markets

    Directory of Open Access Journals (Sweden)

    Cherkasova Victoria

    2016-01-01

    Full Text Available This paper focuses on the efficiency of target-company investment decisions before and after Merger & Acquisition deals. We study whether M&A deals help to solve the problem of suboptimal investment after the acquisition. Using a sample of 145 target companies from BRICS countries that were acquired during the period 2004-2014, we outline those that had over- or underinvested before the deal and show that more than half the companies managed to optimize the investment level after the deal. We determine the key factors that improve the inefficiency of investment decisions and demonstrate that the industry and country have an impact on the degree of suboptimal investment.

  14. Suboptimal treatment adherence in bipolar disorder: impact on clinical outcomes and functioning

    Directory of Open Access Journals (Sweden)

    Montes JM

    2013-01-01

    Full Text Available Jose Manuel Montes1, Jorge Maurino2, Consuelo de Dios3, Esteban Medina21Department of Psychiatry, Hospital Universitario del Sureste, 2AstraZeneca Medical Department, 3Department of Psychiatry, Hospital Universitario La Paz, Madrid, SpainBackground: The primary aim of this study was to assess drug treatment adherence in patients with bipolar disorder and to identify factors associated with adherence. The secondary aim was to analyze the impact of suboptimal adherence on clinical and functional outcomes.Methods: A cross-sectional study was conducted in a sample of outpatients receiving an oral antipsychotic drug. Medication adherence was assessed combining the 10-item Drug Attitude Inventory, the Morisky Green Adherence Questionnaire, and the Compliance Rating Scale. Logistic regression was used to determine significant variables associated with suboptimal adherence to medication.Results: Three hundred and three patients were enrolled into the study. The mean age was 45.9 ± 12.8 years, and 59.7% were females. Sixty-nine percent of patients showed suboptimal adherence. Disease severity and functioning were significantly worse in the suboptimal group than in the adherent group. Multivariate analysis showed depressive polarity of the last acute episode, presence of subsyndromal symptoms, and substance abuse/dependence to be significantly associated with suboptimal treatment adherence (odds ratios 3.41, 2.13, and 1.95, respectively.Conclusion: A high prevalence of nonadherence was found in an outpatient sample with bipolar disorder. Identification of factors related to treatment adherence would give clinicians the opportunity to select more adequately patients who are eligible for potential adherence-focused interventions.Keywords: bipolar disorder, treatment adherence, functioning, polarity, subsyndromal symptoms

  15. Suboptimal care and maternal mortality among foreign-born women in Sweden

    DEFF Research Database (Denmark)

    Esscher, Annika; Binder-Finnema, Pauline; Bødker, Birgit

    2014-01-01

    that occurred in Sweden from 1988-2010. METHODS: A subset of maternal death records (n = 75) among foreign-born women from low- and middle-income countries and Swedish-born women were audited using structured implicit review. One case of foreign-born maternal death was matched with two native born Swedish cases...... language and suboptimal interpreter system or usage. Inadequate care occurred more often among the foreign-born (p = 0.04), whereas delays in consultation/referral and miscommunication between health care providers where equally common between the two groups. CONCLUSIONS: Suboptimal care factors, major...

  16. Visually suboptimal bananas: How ripeness affects consumer expectation and perception.

    Science.gov (United States)

    Symmank, Claudia; Zahn, Susann; Rohm, Harald

    2018-01-01

    One reason for the significant amount of food that is wasted in developed countries is that consumers often expect visually suboptimal food as being less palatable. Using bananas as example, the objective of this study was to determine how appearance affects consumer overall liking, the rating of sensory attributes, purchase intention, and the intended use of bananas. The ripeness degree (RD) of the samples was adjusted to RD 5 (control) and RD 7 (more ripened, visually suboptimal). After preliminary experiments, a total of 233 participants were asked to judge their satisfaction with the intensity of sensory attributes that referred to flavor, taste, and texture using just-about-right scales. Subjects who received peeled samples were asked after tasting, whereas subjects who received unpeeled bananas judged expectation and, after peeling and tasting, perception. Expected overall liking and purchase intention were significantly lower for RD 7 bananas. Purchase intention was still significantly different between RD 5 and RD 7 after tasting, whereas no difference in overall liking was observed. Significant differences between RD 5 and RD 7 were observed when asking participants for their intended use of the bananas. Concerning the sensory attributes, penalty analysis revealed that only the firmness of the RD 7 bananas was still not just-about-right after tasting. The importance that consumers attribute to the shelf-life of food had a pronounced impact on purchase intention of bananas with different ripeness degree. In the case of suboptimal bananas, the results demonstrate a positive relationship between the sensory perception and overall liking and purchase intention. Convincing consumers that visually suboptimal food is still tasty is of high relevance for recommending different ways of communication. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Radiation dose-reduction strategies in thoracic CT.

    Science.gov (United States)

    Moser, J B; Sheard, S L; Edyvean, S; Vlahos, I

    2017-05-01

    Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Hungry pigeons make suboptimal choices, less hungry pigeons do not.

    Science.gov (United States)

    Laude, Jennifer R; Pattison, Kristina F; Zentall, Thomas R

    2012-10-01

    Hungry animals will often choose suboptimally by being attracted to reliable signals for food that occur infrequently (they gamble) over less reliable signals for food that occur more often. That is, pigeons prefer an option that 50 % of the time provides them with a reliable signal for the appearance of food but 50 % of the time provides them with a reliable signal for the absence of food (overall 50 % reinforcement) over an alternative that always provides them with a signal for the appearance of food 75 % of the time (overall 75 % reinforcement). The pigeons appear to choose impulsively for the possibility of obtaining the reliable signal for reinforcement. There is evidence that greater hunger is associated with greater impulsivity. We tested the hypothesis that if the pigeons were less hungry, they would be less impulsive and, thus, would choose more optimally (i.e., on the basis of the overall probability of reinforcement). We found that hungry pigeons choose the 50 % reinforcement alternative suboptimally but less hungry pigeons prefer the more optimal 75 % reinforcement. Paradoxically, pigeons that needed the food more received less of it. These findings have implications for how level of motivation may also affect human suboptimal choice (e.g., purchase of lottery tickets and playing slot machines).

  19. Novel Approaches for Visualizing and Analyzing Dose-Timing Data from Electronic Drug Monitors, or "How the 'Broken Window' Theory Pertains to ART Adherence".

    Science.gov (United States)

    Gill, Christopher J; DeSilva, Mary Bachman; Hamer, Davidson H; Keyi, Xu; Wilson, Ira B; Sabin, Lora

    2015-11-01

    Adherence to antiretroviral medications is usually expressed in terms of the proportion of doses taken. However, the timing of doses taken may also be an important dimension to overall adherence. Little is known about whether patients who mistime doses are also more likely to skip doses. Using data from the completed Adherence for Life randomized controlled trial, we created visual and statistical models to capture and analyze dose timing data collected longitudinally with electronic drug monitors (EDM). From scatter plots depicting dose time versus calendar date, we identified dominant patterns of dose taking and calculated key features [slope of line over calendar date; residual mean standard error (RMSE)]. Each was assessed for its ability to categorize subjects with 'sub-optimal' (<95 % of doses taken) using area under the receiver operating characteristic (AROC) curve analysis. Sixty eight subjects contributed EDM data, with ~300 to 400 observations/subject. While regression line slopes did not predict 'sub-optimal' adherence (AROC 0.51, 95 % CI 0.26-0.75), the variability in dose timing (RMSE) was strongly predictive (AROC 0.79, 95 % CI 0.62-0.97). Compared with the lowest quartile of RMSE (minimal dose time variability), each successive quartile roughly doubled the odds of 'sub-optimal' adherence (OR 2.1, 95 % CI 1.3-3.4). Patterns of dose timing and mistiming are strongly related to overall adherence behavior. Notably, individuals who skip doses are more likely to mistime doses, with the degree of risk positively correlated with the extent of dose timing variability.

  20. Effect of cystamine on rat tissue GSH level and glutathione reductase activity

    International Nuclear Information System (INIS)

    Kovarova, H.; Pulpanova, J.

    1979-01-01

    Reduced glutathione (GSH) level and glutathione reductase activity were determined by means of the spectrophotometric method in various rat tissues after i.p. administration of cystamine (50 mg/kg and 20 mg/kg). GSH amount dropped in the spleen and kidney at 10 and 20 min; following this interval, an increase of GSH level was observed in the liver at 20-30 min, in the spleen and kidney at 60 min after the treatment with a radioprotective cystamine dose (50 mg/kg). The changes in GSH level induced by a non-radioprotective cystamine dose (20 mg/kg) had an opposite tendency. The activity of glutathione reductase was decreased in all tissues studied. As to the mechanism of the radioprotective action, both the inactivation of glutathione reductase activity and the changes in GSH level seem to be the factors contributing to the radioprotective effect of cystamine by strengthening the cellular radioresistance. (orig.) 891 MG/orig. 892 RKD [de

  1. Comparative Performance Analysis of G-RAKE Receivers with Suboptimal Finger Placement

    Directory of Open Access Journals (Sweden)

    K. B. Baltzis

    2014-07-01

    Full Text Available Generalized RAKE (G-RAKE reception reduces the total amount of interference and provides enhanced diversity by comprising extra fingers to collect information about interference and further using channel and impairment correlation estimates for fingers allocation. However, the hardware complexity and the excessive computational requirements of GRAKE receivers may restrict their application in real systems; thus, suboptimal solutions are commonly used. In this paper, we propose and evaluate three maximum likelihood G-RAKE structures for colored noise with suboptimal finger placement. In all implementations, the fingers are optimally distributed within a time window that spans from several chip periods before the first arriving multipath to several chip periods after the latest one. The first receiver has its fingers at integer multiples of the chip period while in the rest two structures the search window is segmented in halves and tenths of the chip duration. This work also extends earlier studies by thoroughly investigating the impact of fractionally spaced finger placement on system performance. Our analysis shows that a suboptimal finger allocation reduces hardware complexity with negligible performance loss. The impact of channel delay spread and processing gain on system performance is also investigated and gives interesting results.

  2. Sub-optimal breastfeeding and its associated factors in rural ...

    African Journals Online (AJOL)

    Similarly, not attending formal education, low birth order and lack of knowledge about exclusive breastfeeding were also negatively associated with exclusive breastfeeding practice. Conclusion: In this study, sub-optimal breast feeding was found to be high. Delayed initiation and non-exclusive breastfeeding practices were ...

  3. Reducing suboptimal employee decisions can build the business case for employee benefits.

    Science.gov (United States)

    Goldsmith, Christopher; Cyboran, Steven F

    2013-01-01

    Suboptimal employee decisions are prevalent in employee benefit plans. Poor decisions have significant consequences for employees and employers. Improving participant decisions produces beneficial outcomes such as lower labor costs, higher productivity and better workforce management. The business case for employee benefits can be strengthened by applying lessons learned from the field of behavioral economics to employee benefit plan design and to workforce communication. This article explains the types of behavioral biases that influence suboptimal decisions and explores how enlightened employee benefit plan choice architecture and vivid behavioral messaging contribute to human and better organizational outcomes.

  4. Conversion coefficients for determining organ doses in paediatric pelvis and hip joint radiography

    International Nuclear Information System (INIS)

    Seidenbusch, Michael C.; Schneider, Karl

    2014-01-01

    Knowledge of organ and effective doses achieved during paediatric X-ray examinations is an important prerequisite for assessment of radiation burden to the patient. Conversion coefficients for reconstruction of organ and effective doses from entrance doses for pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission. Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional pelvis and hip joint radiographs were calculated by performing Monte Carlo simulations in mathematical hermaphrodite phantom models representing patients of different ages. The clinical variation of radiation field settings was taken into consideration by defining optimal and suboptimal standard field settings. Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal beam projection and the standard focus detector distance of 115 cm. The conversion coefficients presented can be used for organ dose assessments from entrance doses measured during pelvis and hip joint radiographs of children and young adults with all field settings within the optimal and suboptimal standard field settings. (orig.)

  5. Suboptimality of Sales Promotions and Improvement Through Channel Coordination

    NARCIS (Netherlands)

    B. Wierenga (Berend); H. Soethoudt (Han)

    2002-01-01

    textabstractThis paper deals with sales promotions in the form of consumer price discounts in fast-moving consumer goods. First, we show analytically that suboptimality is to be expected with respect to the size of the consumer price discount. This is due to the separate decision making of the

  6. The fate of suboptimal anastomosis after colon resection: An experimental study.

    Science.gov (United States)

    Yıldız, Mehmet Kamil; Okan, İsmail; Nazik, Hasan; Bas, Gurhan; Alimoglu, Orhan; İlktac, Mehmet; Daldal, Emin; Sahin, Mustafa; Kuvat, Nuray; Ongen, Betugul

    2014-11-01

    The fate of suboptimal anastomosis is unknown and early detection of anastomotic leakage after colon resection is crucial for the proper management of patients. Twenty-six rats were assigned to "Control", "Leakage" and "Suboptimal anastomosis" groups where they underwent either sham laparotomy, cecal ligation, and puncture or anastomosis with four sutures following colon resection, respectively. At the fifth hour and on the third and ninth days; peripheral blood and peritoneal washing samples through relaparotomy were obtained. The abdomen was inspected macroscopically for anastomotic healing. Polymerase chain reaction (PCR) with 16s rRNA and E.coli-specific primers were run on all samples along with aerobic and anaerobic cultures. The sensitivity and specificity of PCR on different bodily fluids with 16s rRNA and E.coli-specific primers were 100% and 78%, respectively. All samples of peritoneal washing fluids on the third and ninth days showed presence of bacteria in both PCR and culture. The inspection of the abdomen revealed signs of anastomotic leakage in eight rats (80%), whereas mortality related with anastomosis was detected in two (20%). Anastomotic leakage with suboptimal anastomosis after colon resection is high and the early detection is possible by running PCR on peritoneal samples as early as 72 hours.

  7. Reoperation for suboptimal outcomes after deep brain stimulation surgery.

    Science.gov (United States)

    Ellis, Tina-Marie; Foote, Kelly D; Fernandez, Hubert H; Sudhyadhom, Atchar; Rodriguez, Ramon L; Zeilman, Pamela; Jacobson, Charles E; Okun, Michael S

    2008-10-01

    To examine a case series of reoperations for deep brain stimulation (DBS) leads in which clinical scenarios revealed suboptimal outcome from a previous operation. Suboptimally placed DBS leads are one potential reason for unsatisfactory results after surgery for Parkinson's disease (PD), essential tremor (ET), or dystonia. In a previous study of patients who experienced suboptimal results, 19 of 41 patients had misplaced leads. Similarly, another report commented that lead placement beyond a 2- to 3-mm window resulted in inadequate clinical benefit, and, in 1 patient, revision improved outcome. The goal of the current study was to perform an unblinded retrospective chart review of DBS patients with unsatisfactory outcomes who presented for reoperation. Patients who had DBS lead replacements after reoperation were assessed with the use of a retrospective review of an institutional review board-approved movement disorders database. Cases of reoperation for suboptimal clinical benefit were included, and cases of replacement of DBS leads caused by infection or hardware malfunction were excluded. Data points studied included age, disease duration, diagnosis, motor outcomes (the Unified Parkinson Disease Rating Scale III in PD, the Tremor Rating Scale in ET, and the Unified Dystonia Rating Scale in dystonia), quality of life (Parkinson's Disease Questionnaire-39 in PD), and the Clinician Global Impression scale. The data from before and after reoperation were examined to determine the estimated impact of repeat surgery. There were 11 patients with PD, 7 with ET, and 4 with dystonia. The average age of the PD group was 52 years, the disease duration was 10 years, and the average vector distance of the location of the active DBS contact was adjusted 5.5 mm. Six patients (54%) with PD had preoperative off medication on DBS Unified Parkinson Disease Rating Scale scores that could be compared with postoperative off medication on DBS scores. The average improvement across this

  8. Pilot study on the additive effects of berberine and oral type 2 diabetes agents for patients with suboptimal glycemic control

    Directory of Open Access Journals (Sweden)

    Di Pierro F

    2012-07-01

    Full Text Available Francesco Di Pierro,1 Nicola Villanova,2 Federica Agostini,2 Rebecca Marzocchi,2 Valentina Soverini,2 Giulio Marchesini21Scientific Department, Velleja Research, Milano, 2Diseases of Metabolism, S Orsola Malpighi Hospital, Bologna, ItalyBackground: Suboptimal glycemic control is a common situation in diabetes, regardless of the wide range of drugs available to reach glycemic targets. Basic research in diabetes is endeavoring to identify new actives working as insulin savers, use of which could delay the introduction of injectable insulin or reduce the insulin dose needed. Commonly available as a nutraceutical, berberine is a potential candidate.Methods and results: Because its low oral bioavailability can be overcome by P-glycoprotein inhibitors like herbal polyphenols, we have tested the nutraceutical combination of Berberis aristata extract and Silybum marianum extract (Berberol® in type 2 diabetes in terms of its additive effect when combined with a conventional oral regimen for patients with suboptimal glycemic control. After 90 days of treatment, the nutraceutical association had a positive effect on glycemic and lipid parameters, significantly reducing glycosylated hemoglobin, basal insulin, homeostatic model assessment of insulin resistance, total and low-density lipoprotein cholesterol, and triglycerides. A relevant effect was also observed in terms of liver function by measuring aspartate transaminase and alanine transaminase. The product had a good safety profile, with distinctive gastrointestinal side effects likely due to its acarbose-like action.Conclusion: Although further studies should be carried out to confirm our data, Berberol could be considered a good candidate as an adjunctive treatment option in diabetes, especially in patients with suboptimal glycemic control.Keywords: berberine, silymarin, glycosylated hemoglobin, diabetes

  9. Suboptimal Partial Transmit Sequence-Active Interference Cancellation with Particle Swarm Optimization

    Directory of Open Access Journals (Sweden)

    Tarasak Poramate

    2010-01-01

    Full Text Available Active interference cancellation (AIC is an effective technique to provide interference avoidance feature for an ultrawideband (UWB OFDM transmitter. Partial transmit sequence-AIC (PTS-AIC, which was recently proposed as an improvement of AIC, requires high computational complexity by doing the exhaustive search of all possible weighting factors whose number grows exponentially with the number of subblocks used. To reduce the complexity of PTS-AIC, this paper proposes a suboptimal way, called particle swarm optimization (PSO, to choose the weighting factors suboptimally without much performance degradation. Both continuous and discrete versions of PSO have been evaluated, and it has been shown that the discrete PSO is able to reduce the complexity significantly without sacrificing the performance of PTS-AIC in many cases.

  10. Indicators of suboptimal performance embedded in the Wechsler Memory Scale-Fourth Edition (WMS-IV)

    OpenAIRE

    Bouman, Zita; Hendriks, Marc PH; Schmand, Ben A; Kessels, Roy PC; Aldenkamp, Albert

    2016-01-01

    Introduction. Recognition and visual working memory tasks from the Wechsler Memory Scale-Fourth Edition (WMS-IV) have previously been documented as useful indicators for suboptimal performance. The present study examined the clinical utility of the Dutch version of the WMS-IV (WMS-IV-NL) for the identification of suboptimal performance using an analogue study design. Method. The patient group consisted of 59 mixed-etiology patients; the experimental malingerers were 50 healthy individuals...

  11. Indicators of suboptimal performance embedded in the Wechsler Memory Scale-Fourth Edition (WMS-IV)

    OpenAIRE

    Bouman, Zita; Hendriks, Marc P.H.; Schmand, Ben A.; Kessels, Roy P.C.; Aldenkamp, Albert P.

    2016-01-01

    Introduction. Recognition and visual working memory tasks from the Wechsler Memory Scale-Fourth Edition (WMS-IV) have previously been documented as useful indicators for suboptimal performance. The present study examined the clinical utility of the Dutch version of the WMS-IV (WMS-IV-NL) for the identification of suboptimal performance using an analogue study design.Method. The patient group consisted of 59 mixed-etiology patients; the experimental malingerers were 50 healthy individuals who ...

  12. A non-destructive selection method for faster growth at suboptimal temperature in common bean (Phaseolus vulgaris)

    NARCIS (Netherlands)

    Drijfhout, E.; Oeveren, J.C. van; Jansen, R.C.

    1991-01-01

    A non-destructive method has been developed to select common bean (Phaseolus vulgaris L.) plants whose growth is less effected at a suboptimal temperature. Shoot weight was determined at a suboptimal (14°C) and optimal temperature (20°C), 38 days after sowing and accessions identified with a

  13. Suboptimal bonding impairs hormonal, epigenetic and neuronal development in preterm infants, but these impairments can be reversed

    NARCIS (Netherlands)

    Kommers, D.R.; Oei, S.G.; Chen, W.; Feijs, L.M.G.; Bambang Oetomo, S.

    This review aimed to raise awareness of the consequences of suboptimal bonding caused by prematurity. In addition to hypoxia–ischaemia, infection and malnutrition, suboptimal bonding is one of the many unnatural stimuli that preterm infants are exposed to, compromising their physiological

  14. Statin therapy reduces the likelihood of suboptimal blood pressure control among Ugandan adult diabetic patients

    Directory of Open Access Journals (Sweden)

    Lumu W

    2017-02-01

    Full Text Available William Lumu,1 Leaticia Kampiire,2 George Patrick Akabwai,3 Daniel Ssekikubo Kiggundu,4 Davis Kibirige5 1Department of Medicine and Diabetes/Endocrine Unit, Mengo Hospital, 2Infectious Disease Research Collaboration, 3Baylor College of Medicine Children’s Foundation, 4Nephrology Unit, Mulago National Referral and Teaching Hospital, 5Department of Medicine, Uganda Martyrs Hospital Lubaga, Kampala, Uganda Background: Hypertension is one of the recognized risk factors of cardiovascular diseases in adult diabetic patients. High prevalence of suboptimal blood pressure (BP control has been well documented in the majority of studies assessing BP control in diabetic patients in sub-Saharan Africa. In Uganda, there is a dearth of similar studies. This study evaluated the prevalence and correlates of suboptimal BP control in an adult diabetic population in Uganda.Patients and methods: This was a cross-sectional study that enrolled 425 eligible ambulatory adult diabetic patients attending three urban diabetic outpatient clinics over 11 months. Data about their sociodemographic characteristics and clinical history were collected using pre-tested questionnaires. Suboptimal BP control was defined according to the 2015 American Diabetes Association standards of diabetes care guideline as BP levels ≥140/90 mmHg.Results: The mean age of the study participants was 52.2±14.4 years, with the majority being females (283, 66.9%. Suboptimal BP control was documented in 192 (45.3% study participants and was independently associated with the study site (private hospitals; odds ratio 2.01, 95% confidence interval 1.18–3.43, P=0.01 and use of statin therapy (odds ratio 0.5, 95% confidence interval 0.26–0.96, P=0.037.Conclusion: Suboptimal BP control was highly prevalent in this study population. Strategies to improve optimal BP control, especially in the private hospitals, and the use of statin therapy should be encouraged in adult diabetic patients

  15. Suboptimal control of pressurized water reactor power plant using approximate model-following method

    International Nuclear Information System (INIS)

    Tsuji, Masashi; Ogawa, Yuichi

    1987-01-01

    We attempted to develop an effective control system that can successfully manage the nuclear steam supply (NSS) system of a PWR power plant in an operational mode requiring relatively small variations of power. A procedure is proposed for synthesizing control system that is a simple, yet practiced, suboptimal control system. The suboptimal control system is designed in two steps; application of the optimal control theory, based on the linear state-feedback control and the use of an approximate model-following method. This procedure can appreciably reduce the complexity of the structure of the controller by accepting a slight deviation from the optimality and by the use of the output-feedback control. This eliminates the engineering difficulty caused by an incompletely state-feedback that is sometimes encountered in practical applications of the optimal state-feedback control theory to complex large-scale dynamical systems. Digital simulations and graphical studies based on the Bode-diagram demonstrate the effectiveness of the suboptimal control, and the applicability of the proposed design method as well. (author)

  16. Burnout and self-reported suboptimal patient care amongst health care workers providing HIV care in Malawi

    Science.gov (United States)

    Mazenga, Alick C.; Simon, Katie; Yu, Xiaoying; Ahmed, Saeed; Nyasulu, Phoebe; Kazembe, Peter N.; Ngoma, Stanley; Abrams, Elaine J.

    2018-01-01

    Background The well-documented shortages of health care workers (HCWs) in sub-Saharan Africa are further intensified by the increased human resource needs of expanding HIV treatment programs. Burnout is a syndrome of emotional exhaustion (EE), depersonalization (DP), and a sense of low personal accomplishment (PA). HCWs’ burnout can negatively impact the delivery of health services. Our main objective was to examine the prevalence of burnout amongst HCWs in Malawi and explore its relationship to self-reported suboptimal patient care. Methods A cross-sectional study among HCWs providing HIV care in 89 facilities, across eight districts in Malawi was conducted. Burnout was measured using the Maslach Burnout Inventory defined as scores in the mid-high range on the EE or DP subscales. Nine questions adapted for this study assessed self-reported suboptimal patient care. Surveys were administered anonymously and included socio-demographic and work-related questions. Validated questionnaires assessed depression and at-risk alcohol use. Chi-square test or two-sample t-test was used to explore associations between variables and self-reported suboptimal patient care. Bivariate analyses identified candidate variables (p burnout. In the three dimensions of burnout, 55% reported moderate-high EE, 31% moderate-high DP, and 46% low-moderate PA. The majority (89%) reported engaging in suboptimal patient care/attitudes including making mistakes in treatment not due to lack of knowledge/experience (52%), shouting at patients (45%), and not performing diagnostic tests due to a desire to finish quickly (35%). In multivariate analysis, only burnout remained associated with self-reported suboptimal patient care (OR 3.22, [CI 2.11 to 4.90]; pBurnout was common among HCWs providing HIV care and was associated with self-reported suboptimal patient care practices/attitudes. Research is needed to understand factors that contribute to and protect against burnout and that inform the

  17. Relationship between stress-related psychosocial work factors and suboptimal health among Chinese medical staff: a cross-sectional study.

    Science.gov (United States)

    Liang, Ying-Zhi; Chu, Xi; Meng, Shi-Jiao; Zhang, Jie; Wu, Li-Juan; Yan, Yu-Xiang

    2018-03-06

    The study aimed to develop and validate a model to measure psychosocial factors at work among medical staff in China based on confirmatory factor analysis (CFA). The second aim of the current study was to clarify the association between stress-related psychosocial work factors and suboptimal health status. The cross-sectional study was conducted using clustered sampling method. Xuanwu Hospital, a 3A grade hospital in Beijing. Nine hundred and fourteen medical staff aged over 40 years were sampled. Seven hundred and ninety-seven valid questionnaires were collected and used for further analyses. The sample included 94% of the Han population. The Copenhagen Psychosocial Questionnaire (COPSOQ) and the Suboptimal Health Status Questionnaires-25 were used to assess the psychosocial factors at work and suboptimal health status, respectively. CFA was conducted to establish the evaluating method of COPSOQ. A multivariate logistic regression model was used to estimate the relationship between suboptimal health status and stress-related psychosocial work factors among Chinese medical staff. There was a strong correlation among the five dimensions of COPSOQ based on the first-order factor model. Then, we established two second-order factors including negative and positive psychosocial work stress factors to evaluate psychosocial factors at work, and the second-order factor model fit well. The high score in negative (OR (95% CI)=1.47 (1.34 to 1.62), Pwork factors increased and decreased the risk of suboptimal health, respectively. This relationship remained statistically significant after adjusting for confounders and when using different cut-offs of suboptimal health status. Among medical staff, the second-order factor model was a suitable method to evaluate the COPSOQ. The negative and positive psychosocial work stress factors might be the risk and protective factors of suboptimal health, respectively. Moreover, negative psychosocial work stress was the most associated

  18. Sub-optimal control of fuzzy linear dynamical systems under granular differentiability concept.

    Science.gov (United States)

    Mazandarani, Mehran; Pariz, Naser

    2018-05-01

    This paper deals with sub-optimal control of a fuzzy linear dynamical system. The aim is to keep the state variables of the fuzzy linear dynamical system close to zero in an optimal manner. In the fuzzy dynamical system, the fuzzy derivative is considered as the granular derivative; and all the coefficients and initial conditions can be uncertain. The criterion for assessing the optimality is regarded as a granular integral whose integrand is a quadratic function of the state variables and control inputs. Using the relative-distance-measure (RDM) fuzzy interval arithmetic and calculus of variations, the optimal control law is presented as the fuzzy state variables feedback. Since the optimal feedback gains are obtained as fuzzy functions, they need to be defuzzified. This will result in the sub-optimal control law. This paper also sheds light on the restrictions imposed by the approaches which are based on fuzzy standard interval arithmetic (FSIA), and use strongly generalized Hukuhara and generalized Hukuhara differentiability concepts for obtaining the optimal control law. The granular eigenvalues notion is also defined. Using an RLC circuit mathematical model, it is shown that, due to their unnatural behavior in the modeling phenomenon, the FSIA-based approaches may obtain some eigenvalues sets that might be different from the inherent eigenvalues set of the fuzzy dynamical system. This is, however, not the case with the approach proposed in this study. The notions of granular controllability and granular stabilizability of the fuzzy linear dynamical system are also presented in this paper. Moreover, a sub-optimal control for regulating a Boeing 747 in longitudinal direction with uncertain initial conditions and parameters is gained. In addition, an uncertain suspension system of one of the four wheels of a bus is regulated using the sub-optimal control introduced in this paper. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Robotic fish tracking method based on suboptimal interval Kalman filter

    Science.gov (United States)

    Tong, Xiaohong; Tang, Chao

    2017-11-01

    Autonomous Underwater Vehicle (AUV) research focused on tracking and positioning, precise guidance and return to dock and other fields. The robotic fish of AUV has become a hot application in intelligent education, civil and military etc. In nonlinear tracking analysis of robotic fish, which was found that the interval Kalman filter algorithm contains all possible filter results, but the range is wide, relatively conservative, and the interval data vector is uncertain before implementation. This paper proposes a ptimization algorithm of suboptimal interval Kalman filter. Suboptimal interval Kalman filter scheme used the interval inverse matrix with its worst inverse instead, is more approximate nonlinear state equation and measurement equation than the standard interval Kalman filter, increases the accuracy of the nominal dynamic system model, improves the speed and precision of tracking system. Monte-Carlo simulation results show that the optimal trajectory of sub optimal interval Kalman filter algorithm is better than that of the interval Kalman filter method and the standard method of the filter.

  20. Design Of Real-Time Implementable Distributed Suboptimal Control: An LQR Perspective

    KAUST Repository

    Jaleel, Hassan; Shamma, Jeff S.

    2017-01-01

    of establishing a communication link between two base stations with minimum energy consumption. We show through simulations that the performance under the proposed framework is close to the optimal performance and the suboptimal policy can be efficiently

  1. A low-volume polyethylene glycol solution was associated with an increased suboptimal bowel preparation rate but had similar recommendations for an early repeat colonoscopy, procedure times, and adenoma detection rates.

    Directory of Open Access Journals (Sweden)

    Sam C Hankins

    Full Text Available Low-volume polyethylene glycol (PEG bowel preparations are better tolerated by patients than high-volume preparations and may achieve similar preparation quality. However, there is little data comparing their effects on a recommendation for an early repeat colonoscopy (because of a suboptimal preparation, procedure times, adenoma detection rate (ADR, and advanced adenoma detection rate (AADR.This is a retrospective cohort study of outpatient colonoscopies performed during a one-year period at a single academic medical center in which low-volume MoviPrep® (n = 1841 or high-volume Colyte® (n = 1337 was used. All preparations were split-dosed. Appropriate covariates were included in regression models assessing suboptimal preparation quality (fair, poor, or inadequate, procedure times, recommendation for an early repeat colonoscopy, ADR, and AADR.MoviPrep® was associated with an increase in having a suboptimal bowel preparation (OR 1.36; 95% CI: 1.06-1.76, but it was not associated with differences in insertion (p = 0.43, withdrawal (p = 0.22, or total procedure times (p = 0.10. The adjusted percentage with a suboptimal preparation was 11.7% for patients using MoviPrep® and 8.8% for patients using Colyte®. MoviPrep® was not associated with a significant difference in overall ADR (OR 0.93; 95% CI: 0.78-1.11, AADR (OR 1.18; 95% CI: 0.87-1.62, or recommendation for early repeat colonoscopy (OR 1.16; 95% CI: 0.72-1.88.MoviPrep® was associated with a small absolute increase in having a suboptimal preparation, but did not affect recommendations for an early repeat colonoscopy, procedure times, or adenoma detection rates. Mechanisms to reduce financial barriers limiting low-volume preparations should be considered because of their favorable tolerability profile.

  2. Indicators of suboptimal performance embedded in the Wechsler Memory Scale-Fourth Edition (WMS-IV).

    Science.gov (United States)

    Bouman, Zita; Hendriks, Marc P H; Schmand, Ben A; Kessels, Roy P C; Aldenkamp, Albert P

    2016-01-01

    Recognition and visual working memory tasks from the Wechsler Memory Scale-Fourth Edition (WMS-IV) have previously been documented as useful indicators for suboptimal performance. The present study examined the clinical utility of the Dutch version of the WMS-IV (WMS-IV-NL) for the identification of suboptimal performance using an analogue study design. The patient group consisted of 59 mixed-etiology patients; the experimental malingerers were 50 healthy individuals who were asked to simulate cognitive impairment as a result of a traumatic brain injury; the last group consisted of 50 healthy controls who were instructed to put forth full effort. Experimental malingerers performed significantly lower on all WMS-IV-NL tasks than did the patients and healthy controls. A binary logistic regression analysis was performed on the experimental malingerers and the patients. The first model contained the visual working memory subtests (Spatial Addition and Symbol Span) and the recognition tasks of the following subtests: Logical Memory, Verbal Paired Associates, Designs, Visual Reproduction. The results showed an overall classification rate of 78.4%, and only Spatial Addition explained a significant amount of variation (p < .001). Subsequent logistic regression analysis and receiver operating characteristic (ROC) analysis supported the discriminatory power of the subtest Spatial Addition. A scaled score cutoff of <4 produced 93% specificity and 52% sensitivity for detection of suboptimal performance. The WMS-IV-NL Spatial Addition subtest may provide clinically useful information for the detection of suboptimal performance.

  3. Impact of imaging approach on radiation dose and associated cancer risk in children undergoing cardiac catheterization.

    Science.gov (United States)

    Hill, Kevin D; Wang, Chu; Einstein, Andrew J; Januzis, Natalie; Nguyen, Giao; Li, Jennifer S; Fleming, Gregory A; Yoshizumi, Terry K

    2017-04-01

    To quantify the impact of image optimization on absorbed radiation dose and associated risk in children undergoing cardiac catheterization. Various imaging and fluoroscopy system technical parameters including camera magnification, source-to-image distance, collimation, antiscatter grids, beam quality, and pulse rates, all affect radiation dose but have not been well studied in younger children. We used anthropomorphic phantoms (ages: newborn and 5 years old) to measure surface radiation exposure from various imaging approaches and estimated absorbed organ doses and effective doses (ED) using Monte Carlo simulations. Models developed in the National Academies' Biological Effects of Ionizing Radiation VII report were used to compare an imaging protocol optimized for dose reduction versus suboptimal imaging (+20 cm source-to-image-distance, +1 magnification setting, no collimation) on lifetime attributable risk (LAR) of cancer. For the newborn and 5-year-old phantoms, respectively ED changes were as follows: +157% and +232% for an increase from 6-inch to 10-inch camera magnification; +61% and +59% for a 20 cm increase in source-to-image-distance; -42% and -48% with addition of 1-inch periphery collimation; -31% and -46% with removal of the antiscatter grid. Compared with an optimized protocol, suboptimal imaging increased ED by 2.75-fold (newborn) and fourfold (5 years old). Estimated cancer LAR from 30-min of posteroanterior fluoroscopy using optimized versus suboptimal imaging, respectively was 0.42% versus 1.23% (newborn female), 0.20% versus 0.53% (newborn male), 0.47% versus 1.70% (5-year-old female) and 0.16% versus 0.69% (5-year-old male). Radiation-related risks to children undergoing cardiac catheterization can be substantial but are markedly reduced with an optimized imaging approach. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  4. Detection of suboptimal effort with symbol span: development of a new embedded index.

    Science.gov (United States)

    Young, J Christopher; Caron, Joshua E; Baughman, Brandon C; Sawyer, R John

    2012-03-01

    Developing embedded indicators of suboptimal effort on objective neurocognitive testing is essential for detecting increasingly sophisticated forms of symptom feigning. The current study explored whether Symbol Span, a novel Wechsler Memory Scale-fourth edition measure of supraspan visual attention, could be used to discriminate adequate effort from suboptimal effort. Archival data were collected from 136 veterans classified into Poor Effort (n = 42) and Good Effort (n = 94) groups based on symptom validity test (SVT) performance. The Poor Effort group had significantly lower raw scores (p Span test. A raw score cutoff of Span can effectively differentiate veterans with multiple failures on established free-standing and embedded SVTs.

  5. Patterns of marijuana and tobacco use associated with suboptimal self-rated health among US adult ever users of marijuana

    Directory of Open Access Journals (Sweden)

    James Tsai

    2017-06-01

    In conclusion, among adult ever users of marijuana, current tobacco use is high and strongly associated with suboptimal SRH; regular marijuana smoking with or without current tobacco use is significantly associated with suboptimal SRH.

  6. Sub-Optimal Management of Type 2 Diabetes Mellitus – A Local Audit

    African Journals Online (AJOL)

    Original Research: Sub-Optimal Management of Type 2 Diabetes Mellitus – A Local Audit ... despite clinical trial data documenting improved outcomes associated not ... were used to define the Metabolic Syndrome.9 Central obesity was.

  7. Risk factors for suboptimal antiretroviral therapy adherence in HIV-infected adolescents in Gaborone, Botswana: a pilot cross-sectional study

    Directory of Open Access Journals (Sweden)

    Ndiaye M

    2013-09-01

    (HIV viral load <400 copies/mL. Multivariate logistic regression analysis was performed to identify independent predictors of ART non-adherence. Results: The overall median (interquartile range ART adherence was 99% (96.5–100 (N = 82. Seventy-six percent of adolescents had excellent pill count ART adherence levels and 94% achieved virologic suppression. Male adolescents made up 65% of the non-adherent group (P = 0.02. Those who displayed suboptimal ART adherence were more likely to report having ever missed ART doses due to failure to pick up medication at the pharmacy (30.0% versus 9.7%, P = 0.03. In the multivariate logistic regression model, male sex (odds ratio [OR] 3.29, 95% confidence interval [CI] 1.13–9.54; P = 0.03 was the only factor which was independently associated with suboptimal ART adherence. Conclusions: A high proportion of HIV-infected adolescents studied had excellent ART adherence and virologic suppression, with male adolescents at higher risk of suboptimal adherence than females. Further research to investigate how gender relates to suboptimal adherence may aid in the design of targeted intervention strategies. Keywords: HIV/AIDS, ART adherence, adolescents, barriers, Botswana

  8. Suboptimal vitamin K status despite supplementation in children and young adults with cystic fibrosis.

    Science.gov (United States)

    Dougherty, Kelly A; Schall, Joan I; Stallings, Virginia A

    2010-09-01

    For children and adolescents with cystic fibrosis (CF) and pancreatic insufficiency, the efficacy of routine vitamin K supplementation to normalize vitamin K status remains unclear. This study examined and determined predictors of vitamin K status in subjects aged 8-25 y with CF and pancreatic insufficiency taking various vitamin K supplements. In 97 subjects, serum 25-hydroxyvitamin D [25(OH)D], dietary intake, vitamin K supplement intake, and vitamin K statusmdashdetermined on the basis of the percentage of serum undercarboxylated osteocalcin (%ucOC; sufficient: lt 20%) and plasma proteins induced by vitamin K absence-factor II (PIVKA-II; n = 60; sufficient: le 2 microg/L)mdashwere assessed. The vitamin K supplementation groups were as follows: lt 150 microg/d (low; multivitamins or no supplement), 150-999 microg/d (middle; CF-specific vitamins), and ge 1000 microg/d (high; mephyton). %ucOC values were compared with 140 healthy subjects aged 6-21 y. In subjects with CF, the median (range) %ucOC was 35% (3%, 76%) and the median (range) for PIVKA-II was 2 (0, 42) micro g/L. Subjects with CF had a higher %ucOC with low [45% (10%, 76%)] and medium [41% (3%, 66%)] supplement intakes but not with a high supplement intake [16% (4%, 72%)] compared with healthy subjects [23% (0%, 43%); both P lt 0.05]. Supplementation group for males and females and 25(OH)D and age for males were significant predictors of vitamin K status. Vitamin K status was often suboptimal despite routine supplementation. Only subjects taking high-dose vitamin K achieved a status similar to healthy subjects, and only the vitamin K supplementation dose predicted vitamin K status for males and females. These data suggest that higher doses of vitamin K are required.

  9. Level of suboptimal adherence to first line antiretroviral treatment & its determinants among HIV positive people in India.

    Science.gov (United States)

    Joshi, Beena; Chauhan, Sanjay; Pasi, Achhelal; Kulkarni, Ragini; Sunil, Nithya; Bachani, Damodar; Mankeshwar, Ranjit

    2014-07-01

    National Anti-retroviral treatment (ART) programme in India was launched in 2004. Since then, there has been no published country representative estimate of suboptimal adherence among people living with HIV (PLHIV) on first line ART in public settings. Hence a multicentric study was undertaken in 15 States of India to assess the level of suboptimal adherence and its determinants among PLHIV. Using a prospective observational study design, 3285 PLHIV were enrolled and followed up to six months across 30 ART centres in India. Adherence was assessed using pill count and self-reported recall method and determinants of suboptimal adherence were explored based on the responses to various issues as perceived by them. Suboptimal adherence was found in 24.5 per cent PLHIV. Determinants of suboptimal adherence were illiteracy (OR--1.341, CI--1.080-1.665), on ART for less than 6 months (OR--1.540, CI--1.280-1.853), male gender (OR for females--0.807, CI--0.662-0.982), tribals (OR--2.246, CI--1.134-4.447), on efavirenz (EFA) regimen (OR--1.479, CI--1.190-1.837), presence of anxiety (OR--1.375, CI--1.117-1.692), non-disclosure of HIV status to family (OR--1.549, CI--1.176-2.039), not motivated for treatment (OR--1.389, CI--1.093-1.756), neglect from friends (OR--1.368, CI--1.069-1.751), frequent change of residence (OR--3.373, CI--2.659-4.278), travel expenses (OR--1.364, CI--1.138-1.649), not meeting the PLHIV volunteer/community care coordinator at the ART center (OR--1.639, CI--1.330-2.019). To enhance identification of PLHIV vulnerable to suboptimal adherence, the existing checklist to identify the barriers to adherence in the National ART Guidelines needs to be updated based on the study findings. Quality of comprehensive adherence support services needs to be improved coupled with vigilant monitoring of adherence measurement.

  10. Level of suboptimal adherence to first line antiretroviral treatment & its determinants among HIV positive people in India

    Directory of Open Access Journals (Sweden)

    Beena Joshi

    2014-01-01

    Full Text Available Background & objectives: National Anti-retroviral treatment (ART programme in India was launched in 2004. Since then, there has been no published country representative estimate of suboptimal adherence among people living with HIV (PLHIV on first line ART in public settings. Hence a multicentric study was undertaken in 15 States of India to assess the level of suboptimal adherence and its determinants among PLHIV. Methods: Using a prospective observational study design, 3285 PLHIV were enrolled and followed up to six months across 30 ART centres in India. Adherence was assessed using pill count and self-reported recall method and determinants of suboptimal adherence were explored based on the responses to various issues as perceived by them. Results: Suboptimal adherence was found in 24.5 per cent PLHIV. Determinants of suboptimal adherence were illiteracy (OR-1.341, CI-1.080-1.665 , on ART for less than 6 months (OR-1.540, CI- 1.280-1.853, male gender (OR for females -0.807, CI- 0.662-0.982, tribals (OR-2.246, CI-1.134-4.447, on efavirenz (EFA regimen (OR- 1.479, CI - 1.190 - 1.837, presence of anxiety (OR- 1.375, CI - 1.117 - 1.692, non-disclosure of HIV status to family (OR- 1.549, CI - 1.176 - 2.039, not motivated for treatment (OR- 1.389, CI - 1.093 - 1.756, neglect from friends (OR-1.368, CI-1.069-1.751, frequent change of residence (OR- 3.373, CI - 2.659 - 4.278, travel expenses (OR- 1.364, CI - 1.138-1.649, not meeting the PLHIV volunteer/community care coordinator at the ART center (OR-1.639, CI-1.330-2.019. Interpretation & conclusions: To enhance identification of PLHIV vulnerable to suboptimal adherence, the existing checklist to identify the barriers to adherence in the National ART Guidelines needs to be updated based on the study findings. Quality of comprehensive adherence support services needs to be improved coupled with vigilant monitoring of adherence measurement.

  11. Applications of sub-optimality in dynamic programming to location and construction of nuclear fuel processing plant

    International Nuclear Information System (INIS)

    Thiriet, L.; Deledicq, A.

    1968-09-01

    First, the point of applying Dynamic Programming to optimization and Operational Research problems in chemical industries are recalled, as well as the conditions in which a dynamic program is illustrated by a sequential graph. A new algorithm for the determination of sub-optimal politics in a sequential graph is then developed. Finally, the applications of sub-optimality concept is shown when taking into account the indirect effects related to possible strategies, or in the case of stochastic choices and of problems of the siting of plants... application examples are given. (authors) [fr

  12. Sub-optimal vitamin B-12 levels among ART-naive HIV-positive individuals in an urban cohort in Uganda.

    Directory of Open Access Journals (Sweden)

    Aggrey S Semeere

    Full Text Available Malnutrition is common among HIV-infected individuals and is often accompanied by low serum levels of micronutrients. Vitamin B-12 deficiency has been associated with various factors including faster HIV disease progression and CD4 depletion in resource-rich settings. To describe prevalence and factors associated with sub-optimal vitamin B-12 levels among HIV-infected antiretroviral therapy (ART naïve adults in a resource-poor setting, we performed a cross-sectional study with a retrospective chart review among individuals attending either the Mulago-Mbarara teaching hospitals' Joint AIDS Program (MJAP or the Infectious Diseases Institute (IDI clinics, in Kampala, Uganda. Logistic regression was used to determine factors associated with sub-optimal vitamin B-12. The mean vitamin B-12 level was 384 pg/ml, normal range (200-900. Sub-optimal vitamin B-12 levels (<300 pg/ml were found in 75/204 (36.8%. Twenty-one of 204 (10.3% had vitamin B-12 deficiency (<200 pg/ml while 54/204 (26.5% had marginal depletion (200-300 pg/ml. Irritable mood was observed more among individuals with sub-optimal vitamin B-12 levels (OR 2.5, 95% CI; 1.1-5.6, P=0.03. Increasing MCV was associated with decreasing serum B-12 category; 86.9 fl (± 5.1 vs. 83 fl (± 8.4 vs. 82 fl (± 8.4 for B-12 deficiency, marginal and normal B-12 categories respectively (test for trend, P=0.017. Compared to normal B-12, individuals with vitamin B-12 deficiency had a longer known duration of HIV infection: 42.2 months (± 27.1 vs. 29.4 months (± 23.8; P=0.02. Participants eligible for ART (CD4<350 cells/µl with sub-optimal B-12 had a higher mean rate of CD4 decline compared to counterparts with normal B-12; 118 (± 145 vs. 22 (± 115 cells/µl/year, P=0.01 respectively. The prevalence of a sub-optimal vitamin B-12 was high in this HIV-infected, ART-naïve adult clinic population in urban Uganda. We recommend prospective studies to further clarify the causal relationships of sub-optimal

  13. Optimal inference with suboptimal models: Addiction and active Bayesian inference

    Science.gov (United States)

    Schwartenbeck, Philipp; FitzGerald, Thomas H.B.; Mathys, Christoph; Dolan, Ray; Wurst, Friedrich; Kronbichler, Martin; Friston, Karl

    2015-01-01

    When casting behaviour as active (Bayesian) inference, optimal inference is defined with respect to an agent’s beliefs – based on its generative model of the world. This contrasts with normative accounts of choice behaviour, in which optimal actions are considered in relation to the true structure of the environment – as opposed to the agent’s beliefs about worldly states (or the task). This distinction shifts an understanding of suboptimal or pathological behaviour away from aberrant inference as such, to understanding the prior beliefs of a subject that cause them to behave less ‘optimally’ than our prior beliefs suggest they should behave. Put simply, suboptimal or pathological behaviour does not speak against understanding behaviour in terms of (Bayes optimal) inference, but rather calls for a more refined understanding of the subject’s generative model upon which their (optimal) Bayesian inference is based. Here, we discuss this fundamental distinction and its implications for understanding optimality, bounded rationality and pathological (choice) behaviour. We illustrate our argument using addictive choice behaviour in a recently described ‘limited offer’ task. Our simulations of pathological choices and addictive behaviour also generate some clear hypotheses, which we hope to pursue in ongoing empirical work. PMID:25561321

  14. Suboptimal Choice in Pigeons: Stimulus Value Predicts Choice over Frequencies.

    Directory of Open Access Journals (Sweden)

    Aaron P Smith

    Full Text Available Pigeons have shown suboptimal gambling-like behavior when preferring a stimulus that infrequently signals reliable reinforcement over alternatives that provide greater reinforcement overall. As a mechanism for this behavior, recent research proposed that the stimulus value of alternatives with more reliable signals for reinforcement will be preferred relatively independently of their frequencies. The present study tested this hypothesis using a simplified design of a Discriminative alternative that, 50% of the time, led to either a signal for 100% reinforcement or a blackout period indicative of 0% reinforcement against a Nondiscriminative alternative that always led to a signal that predicted 50% reinforcement. Pigeons showed a strong preference for the Discriminative alternative that remained despite reducing the frequency of the signal for reinforcement in subsequent phases to 25% and then 12.5%. In Experiment 2, using the original design of Experiment 1, the stimulus following choice of the Nondiscriminative alternative was increased to 75% and then to 100%. Results showed that preference for the Discriminative alternative decreased only when the signals for reinforcement for the two alternatives predicted the same probability of reinforcement. The ability of several models to predict this behavior are discussed, but the terminal link stimulus value offers the most parsimonious account of this suboptimal behavior.

  15. Self-care practices of Malaysian adults with diabetes and sub-optimal glycaemic control.

    Science.gov (United States)

    Tan, Ming Yeong; Magarey, Judy

    2008-08-01

    To investigate the self-care practices of Malaysian adults with diabetes and sub-optimal glycaemic control. Using a one-to-one interviewing approach, data were collected from 126 diabetic adults from four settings. A 75-item questionnaire was used to assess diabetes-related knowledge and self-care practices regarding, diet, medication, physical activity and self-monitoring of blood glucose (SMBG). Most subjects had received advice on the importance of self-care in the management of their diabetes and recognised its importance. Sixty-seven subjects (53%) scored below 50% in their diabetes-related knowledge. Subjects who consumed more meals per day (80%), or who did not include their regular sweetened food intakes in their daily meal plan (80%), or who were inactive in daily life (54%), had higher mean fasting blood glucose levels (p=0.04). Subjects with medication non-adherence (46%) also tended to have higher fasting blood glucose levels. Only 15% of the subjects practiced SMBG. Predictors of knowledge deficit and poor self-care were low level of education (p = <0.01), older subjects (p=0.04) and Type 2 diabetes subjects on oral anti-hyperglycaemic medication (p = <0.01). There were diabetes-related knowledge deficits and inadequate self-care practices among the majority of diabetic patients with sub-optimal glycaemic control. This study should contribute to the development of effective education strategies to promote health for adults with sub-optimal diabetes control.

  16. Suboptimal Criterion Learning in Static and Dynamic Environments.

    Directory of Open Access Journals (Sweden)

    Elyse H Norton

    2017-01-01

    Full Text Available Humans often make decisions based on uncertain sensory information. Signal detection theory (SDT describes detection and discrimination decisions as a comparison of stimulus "strength" to a fixed decision criterion. However, recent research suggests that current responses depend on the recent history of stimuli and previous responses, suggesting that the decision criterion is updated trial-by-trial. The mechanisms underpinning criterion setting remain unknown. Here, we examine how observers learn to set a decision criterion in an orientation-discrimination task under both static and dynamic conditions. To investigate mechanisms underlying trial-by-trial criterion placement, we introduce a novel task in which participants explicitly set the criterion, and compare it to a more traditional discrimination task, allowing us to model this explicit indication of criterion dynamics. In each task, stimuli were ellipses with principal orientations drawn from two categories: Gaussian distributions with different means and equal variance. In the covert-criterion task, observers categorized a displayed ellipse. In the overt-criterion task, observers adjusted the orientation of a line that served as the discrimination criterion for a subsequently presented ellipse. We compared performance to the ideal Bayesian learner and several suboptimal models that varied in both computational and memory demands. Under static and dynamic conditions, we found that, in both tasks, observers used suboptimal learning rules. In most conditions, a model in which the recent history of past samples determines a belief about category means fit the data best for most observers and on average. Our results reveal dynamic adjustment of discrimination criterion, even after prolonged training, and indicate how decision criteria are updated over time.

  17. Suboptimal Antituberculosis Drug Concentrations and Outcomes in Small and HIV-Coinfected Children in India: Recommendations for Dose Modifications.

    Science.gov (United States)

    Guiastrennec, Benjamin; Ramachandran, Geetha; Karlsson, Mats O; Kumar, A K Hemanth; Bhavani, Perumal Kannabiran; Gangadevi, N Poorana; Swaminathan, Soumya; Gupta, Amita; Dooley, Kelly E; Savic, Radojka M

    2017-12-16

    This work aimed to evaluate the once-daily antituberculosis treatment as recommended by the new Indian pediatric guidelines. Isoniazid, rifampin, and pyrazinamide concentration-time profiles and treatment outcome were obtained from 161 Indian children with drug-sensitive tuberculosis undergoing thrice-weekly dosing as per previous Indian pediatric guidelines. The exposure-response relationships were established using a population pharmacokinetic-pharmacodynamic approach. Rifampin exposure was identified as the unique predictor of treatment outcome. Consequently, children with low body weight (4-7 kg) and/or HIV infection, who displayed the lowest rifampin exposure, were associated with the highest probability of unfavorable treatment (therapy failure, death) outcome (P unfavorable ). Model-based simulation of optimized (P unfavorable ≤ 5%) rifampin once-daily doses were suggested per treatment weight band and HIV coinfection status (33% and 190% dose increase, respectively, from the new Indian guidelines). The established dose-exposure-response relationship could be pivotal in the development of future pediatric tuberculosis treatment guidelines. © 2017, The Authors Clinical Pharmacology & Therapeutics published by Wiley Periodicals, Inc. on behalf of American Society for Clinical Pharmacology and Therapeutics.

  18. Risk of suboptimal iodine intake in pregnant Norwegian women.

    Science.gov (United States)

    Brantsæter, Anne Lise; Abel, Marianne Hope; Haugen, Margaretha; Meltzer, Helle Margrete

    2013-02-06

    Pregnant women and infants are exceptionally vulnerable to iodine deficiency. The aims of the present study were to estimate iodine intake, to investigate sources of iodine, to identify predictors of low or suboptimal iodine intake (defined as intakes below 100 μg/day and 150 μg/day) in a large population of pregnant Norwegian women and to evaluate iodine status in a sub-population. Iodine intake was calculated based on a validated Food Frequency Questionnaire in the Norwegian Mother and Child Cohort. The median iodine intake was 141 μg/day from food and 166 μg/day from food and supplements. Use of iodine-containing supplements was reported by 31.6%. The main source of iodine from food was dairy products, contributing 67% and 43% in non-supplement and iodine-supplement users, respectively. Of 61,904 women, 16.1% had iodine intake below 100 μg/day, 42.0% had iodine intake below 150 μg/day and only 21.7% reached the WHO/UNICEF/ICCIDD recommendation of 250 μg/day. Dietary behaviors associated with increased risk of low and suboptimal iodine intake were: no use of iodine-containing supplements and low intake of milk/yogurt, seafood and eggs. The median urinary iodine concentration measured in 119 participants (69 μg/L) confirmed insufficient iodine intake. Public health strategies are needed to improve and secure the iodine status of pregnant women in Norway.

  19. Suboptimal processor for anomaly detection for system surveillance and diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Ciftcioglu, Oe.; Hoogenboom, J.E.; Dam, H. van

    1989-06-01

    Anomaly detection for nuclear reactor surveillance and diagnosis is described. The residual noise obtained as a result of autoregressive (AR) modelling is essential to obtain high sensitivity for anomaly detection. By means of the method of hypothesis testing a suboptimal anomaly detection processor is devised for system surveillance and diagnosis. Experiments are carried out to investigate the performance of the processor, which is in particular of interest for on-line and real-time applications.

  20. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  1. Sub-optimal vitamin B-12 levels among ART-naïve HIV-positive individuals in an urban cohort in Uganda.

    Science.gov (United States)

    Semeere, Aggrey S; Nakanjako, Damalie; Ddungu, Henry; Kambugu, Andrew; Manabe, Yukari C; Colebunders, Robert

    2012-01-01

    Malnutrition is common among HIV-infected individuals and is often accompanied by low serum levels of micronutrients. Vitamin B-12 deficiency has been associated with various factors including faster HIV disease progression and CD4 depletion in resource-rich settings. To describe prevalence and factors associated with sub-optimal vitamin B-12 levels among HIV-infected antiretroviral therapy (ART) naïve adults in a resource-poor setting, we performed a cross-sectional study with a retrospective chart review among individuals attending either the Mulago-Mbarara teaching hospitals' Joint AIDS Program (MJAP) or the Infectious Diseases Institute (IDI) clinics, in Kampala, Uganda. Logistic regression was used to determine factors associated with sub-optimal vitamin B-12. The mean vitamin B-12 level was 384 pg/ml, normal range (200-900). Sub-optimal vitamin B-12 levels (ART (CD4ART-naïve adult clinic population in urban Uganda. We recommend prospective studies to further clarify the causal relationships of sub-optimal vitamin B-12, and explore the role of vitamin B-12 supplementation in immune recovery.

  2. TECHNOLOGICAL INNOVATION AND BUSINESS DIVERSIFICATION: SUSTAINABILITY LIVELIHOODS IMPROVEMENT SCENARIO OF RICE FARMER HOUSEHOLD IN SUB-OPTIMAL LAND

    Directory of Open Access Journals (Sweden)

    Adriani D.

    2017-09-01

    Full Text Available The increased role of the sub-optimal land to support food security continue to be encouraged in Indonesia, given the more limited expansion for potential land. But until recently, development of sub-optimal land becomes not an easy thing. Ecological and technical barriers became the main issue. A series of these issues resulted in a high number of underemproleymeny and poverty in agriculture region. Technological inovation of agriculture and the business diversification can be seen be the solution to those issues. This research aims to analyze the impact of the technological innovation and business diversification on underemployment, working time, household income and also sustainable livelihoods of farmers on the sub-optimal land. The research was carried out in Pemulutan District, Ogan Ilir Regency, South Sumatra Province, Indonesia. The objects of research are farmers which adopter and non adopter technological innovation, and also work outside of paddy farming (business diversification. The research method is the survey. Method of sampling is stratified random sampling. Data obtained in the field analyses using descriptive statistics and inferesia. The results showed there are positive impact of technological innovation on the allocation of working time farmer households, the numbers underemployment, household income and livelihood sustainability. Determinant factors for farmers in applying technology and business diversification are paddy farming income, off-farm income, and age. The use of technology and business diversification proves to be one of the positive scenarios for sustainable livelihood of farmers in sub-optimal land.

  3. Characteristics influencing therapy switch behavior after suboptimal response to first-line treatment in patients with multiple sclerosis.

    Science.gov (United States)

    Teter, Barbara; Agashivala, Neetu; Kavak, Katelyn; Chouhfeh, Lynn; Hashmonay, Ron; Weinstock-Guttman, Bianca

    2014-06-01

    Factors driving disease-modifying therapy (DMT) switch behavior are not well understood. The objective of this paper is to identify patient characteristics and clinical events predictive of therapy switching in patients with suboptimal response to DMT. This retrospective study analyzed patients with relapsing-remitting multiple sclerosis (MS) and a suboptimal response to initial therapy with either interferon β or glatiramer acetate. Suboptimal responders were defined as patients with ≥1 MS event (clinical relapse, worsening disability, or MRI worsening) while on DMT. Switchers were defined as those who changed DMT within six to 12 months after the MS event. Of 606 suboptimal responders, 214 (35.3%) switched therapy. Switchers were younger at symptom onset (p = 0.012), MS diagnosis (p = 0.004), DMT initiation (p < 0.001), and first MS event (p = 0.011) compared with nonswitchers. Compared with one relapse alone, MRI worsening alone most strongly predicted switch behavior (odds ratio 6.3; 95% CI, 3.1-12.9; p < 0.001), followed by ≥2 relapses (2.8; 95% CI, 1.1-7.3; p = 0.040), EDSS plus MRI worsening (2.5; 95% CI, 1.1-5.9; p = 0.031) and EDSS worsening alone (2.2; 95% CI, 1.2-4.1; p = 0.009). Younger patients with disease activity, especially MRI changes, are more likely to have their therapy switched sooner than patients who are older at the time of MS diagnosis and DMT initiation. © The Author(s) 2013.

  4. High Prevalence of Suboptimal Vitamin D Status and Bone Loss in Adult Short Bowel Syndrome Even After Weaning Off Parenteral Nutrition.

    Science.gov (United States)

    Fan, Shengxian; Ni, Xiaodong; Wang, Jian; Zhang, Yongliang; Tao, Shen; Kong, Wencheng; Li, Yousheng; Li, Jieshou

    2017-04-01

    Previous studies have noticed the high incidence of suboptimal vitamin D (VtD) status and bone loss in short bowel syndrome (SBS) with parenteral nutrition (PN) dependence. However, limited data have focused on adult SBS without PN dependence. Therefore, our objective was to investigate the incidence and risk factors of suboptimal VtD status and bone loss in adult SBS even after weaning off PN. We performed a prospective study of 60 adult patients with SBS. Serum 25-hydroxyvitamin D (25-OHD) was measured by radioimmunoassay. Bone mineral density (BMD) was measured using dual-energy x-ray absorptiometry (DEXA). Medical records and various laboratory parameters were collected in all participants. Suboptimal VtD status was identified in all individuals, including 3 (5.0%) with VtD insufficiency and 57 (95.0%) with VtD deficiency. Residual small bowel length (B, 0.072, P = .001) and duration of SBS (B, -0.066, P = .020) were both significantly correlated with suboptimal VtD levels. Overall, only 2 patients presented a normal BMD; osteopenia and osteoporosis were noted in 41 (68.3%) and 17 (28.3%) individuals, respectively. Low 25-OHD concentration was associated with a decreased BMD (B, 0.065, P = .029). There were no other demographic characteristics or clinical examinations associated with suboptimal VtD levels and bone loss. Suboptimal VtD status and bone loss were common in adult SBS even after weaning off PN. Despite routine oral VtD supplementation, most patients did not achieve satisfactory status. This emphasizes the critical importance of routine surveillance of 25-OHD and BMD, as well as consideration of alternative methods of supplementation after weaning off PN.

  5. Prevalence and correlates of suboptimal vitamin D status in people living with psychotic disorders: Data from the Australian Survey of High Impact Psychosis.

    Science.gov (United States)

    Suetani, Shuichi; Saha, Sukanta; Eyles, Darryl W; Scott, James G; McGrath, John J

    2017-09-01

    Having sufficient sera concentrations of 25-hydroxyvitamin D is important for a range of health outcomes including cardiometabolic diseases. Clinical studies in people with psychotic disorders suggest that a sizable proportion has suboptimal vitamin D status (i.e. vitamin D deficiency or insufficiency). Individuals with psychosis also have many of the risk factors associated with suboptimal vitamin D status such as smoking, obesity, and reduced physical activity. The aim of this study was to examine the prevalence and socio-demographic and clinical correlates of vitamin D status using a large, population-based sample of adults with psychotic disorders. Data were collected as part of the Survey of High Impact Psychosis, a population-based survey of Australians aged 18-64 years with a psychotic disorder. 25-Hydroxyvitamin D concentration was measured in 463 participants. 25-Hydroxyvitamin D concentration was dichotomised into optimal (above 50 nmol/L) and suboptimal (below 50 nmol/L). The influence of a range of socio-demographic and clinical variables on vitamin D status was examined using logistic regression. Nearly half (43.6%) of the participants had suboptimal vitamin D status. Those with (a) increased physical activity or (b) positive symptoms had significantly reduced odds of having suboptimal vitamin D status. However, there were no significant associations between suboptimal vitamin D status and other psychiatric symptom measures or cardiometabolic risk factors. Many people with psychotic disorders have suboptimal vitamin D status. As part of the routine assessment of physical health status, clinicians should remain mindful of vitamin D status in this vulnerable population and encourage the use of appropriate vitamin D supplements.

  6. Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children

    International Nuclear Information System (INIS)

    Yoon, Haesung; Kim, Myung-Joon; Shin, Hyun Joo; Kim, Hyun Gi; Lee, Mi-Jung; Yoon, Choon-Sik; Choi, Jiin

    2015-01-01

    New CT reconstruction techniques may help reduce the burden of ionizing radiation. To quantify radiation dose reduction when performing pediatric chest CT using a low-dose protocol and 50% adaptive statistical iterative reconstruction (ASIR) compared with age/gender-matched chest CT using a conventional dose protocol and reconstructed with filtered back projection (control group) and to determine its effect on image quality in normal weight and overweight children. We retrospectively reviewed 40 pediatric chest CT (M:F = 21:19; range: 0.1-17 years) in both groups. Radiation dose was compared between the two groups using paired Student's t-test. Image quality including noise, sharpness, artifacts and diagnostic acceptability was subjectively assessed by three pediatric radiologists using a four-point scale (superior, average, suboptimal, unacceptable). Eight children in the ASIR group and seven in the control group were overweight. All radiation dose parameters were significantly lower in the ASIR group (P < 0.01) with a greater than 57% dose reduction in overweight children. Image noise was higher in the ASIR group in both normal weight and overweight children. Only one scan in the ASIR group (1/40, 2.5%) was rated as diagnostically suboptimal and there was no unacceptable study. In both normal weight and overweight children, the ASIR technique is associated with a greater than 57% mean dose reduction, without significantly impacting diagnostic image quality in pediatric chest CT examinations. However, CT scans in overweight children may have a greater noise level, even when using the ASIR technique. (orig.)

  7. Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Haesung; Kim, Myung-Joon; Shin, Hyun Joo; Kim, Hyun Gi; Lee, Mi-Jung [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Yoon, Choon-Sik [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Choi, Jiin [Yonsei University College of Medicine, Biostatistics Collaboration Unit, Seoul (Korea, Republic of)

    2015-03-01

    New CT reconstruction techniques may help reduce the burden of ionizing radiation. To quantify radiation dose reduction when performing pediatric chest CT using a low-dose protocol and 50% adaptive statistical iterative reconstruction (ASIR) compared with age/gender-matched chest CT using a conventional dose protocol and reconstructed with filtered back projection (control group) and to determine its effect on image quality in normal weight and overweight children. We retrospectively reviewed 40 pediatric chest CT (M:F = 21:19; range: 0.1-17 years) in both groups. Radiation dose was compared between the two groups using paired Student's t-test. Image quality including noise, sharpness, artifacts and diagnostic acceptability was subjectively assessed by three pediatric radiologists using a four-point scale (superior, average, suboptimal, unacceptable). Eight children in the ASIR group and seven in the control group were overweight. All radiation dose parameters were significantly lower in the ASIR group (P < 0.01) with a greater than 57% dose reduction in overweight children. Image noise was higher in the ASIR group in both normal weight and overweight children. Only one scan in the ASIR group (1/40, 2.5%) was rated as diagnostically suboptimal and there was no unacceptable study. In both normal weight and overweight children, the ASIR technique is associated with a greater than 57% mean dose reduction, without significantly impacting diagnostic image quality in pediatric chest CT examinations. However, CT scans in overweight children may have a greater noise level, even when using the ASIR technique. (orig.)

  8. Design Of Real-Time Implementable Distributed Suboptimal Control: An LQR Perspective

    KAUST Repository

    Jaleel, Hassan

    2017-09-29

    We propose a framework for multiagent systems in which the agents compute their control actions in real time, based on local information only. The novelty of the proposed framework is that the process of computing a suboptimal control action is divided into two phases: an offline phase and an online phase. In the offline phase, an approximate problem is formulated with a cost function that is close to the optimal cost in some sense and is distributed, i.e., the costs of non-neighboring nodes are not coupled. This phase is centralized and is completed before the deployment of the system. In the online phase, the approximate problem is solved in real time by implementing any efficient distributed optimization algorithm. To quantify the performance loss, we derive upper bounds for the maximum error between the optimal performance and the performance under the proposed framework. Finally, the proposed framework is applied to an example setup in which a team of mobile nodes is assigned the task of establishing a communication link between two base stations with minimum energy consumption. We show through simulations that the performance under the proposed framework is close to the optimal performance and the suboptimal policy can be efficiently implemented online.

  9. Evaluation of patient dose in some mammography centres in Iran

    International Nuclear Information System (INIS)

    Paknyat, A.; Samarin, E. R. P.; Jeshvaghane, N. A.; Paydar, R.; Fasaei, B.; Karamloo, A.; Khosravi, H. R.; Deevband, M. R.

    2011-01-01

    High diagnostic sensitivity and specificity while maintaining the least dose to the patient is the ideal mammography. The objective of this work was to evaluate patient dose and image quality of mammograms to propose corrective actions. The image quality for 1242 patient in 7 mammography facilities in Tehran city was evaluated based on selected image quality criteria using a three-point scale. Clinical image quality, the entrance surface air kerma, the average glandular dose and optical density of films for standard PMMA phantom of 4.5 cm thickness were evaluated. The results showed that up to 72 % of mammograms were in good condition to be diagnosed, and only about 3.4 % of the images were unacceptable or with suboptimal quality. The entrance surface air kerma values were in the range of 3.8-10.5 mGy, average glandular dose 0.5-1.8 mGy and optical density of films 0.74-2.03. The image quality evaluation after correction actions, periodic image quality evaluation and using the correct equipment certainly will improve patient dose. (authors)

  10. Influence of Suboptimally and Optimally Presented Affective Pictures and Words on Consumption-Related Behavior

    Science.gov (United States)

    Winkielman, Piotr; Gogolushko, Yekaterina

    2018-01-01

    Affective stimuli can influence immediate reactions as well as spontaneous behaviors. Much evidence for such influence comes from studies of facial expressions. However, it is unclear whether these effects hold for other affective stimuli, and how the amount of stimulus processing changes the nature of the influence. This paper addresses these issues by comparing the influence on consumption behaviors of emotional pictures and valence-matched words presented at suboptimal and supraliminal durations. In Experiment 1, both suboptimal and supraliminal emotional facial expressions influenced consumption in an affect-congruent, assimilative way. In Experiment 2, pictures of both high- and low-frequency emotional objects congruently influenced consumption. In comparison, words tended to produce incongruent effects. We discuss these findings in light of privileged access theories, which hold that pictures better convey affective meaning than words, and embodiment theories, which hold that pictures better elicit somatosensory and motor responses. PMID:29434556

  11. Point prevalence of suboptimal footwear features among ambulant older hospital patients: implications for fall prevention.

    Science.gov (United States)

    Chari, Satyan R; McRae, Prue; Stewart, Matthew J; Webster, Joan; Fenn, Mary; Haines, Terry P

    2016-09-01

    Objective The aim of the present study was to establish the point prevalence of 'suboptimal' features in footwear reported to have been used by older hospital patients when ambulating, and to explore underpinning factors for their choice of footwear. Method A cross-sectional investigation was undertaken on 95 of 149 eligible in-patients across 22 high fall-risk wards in a large metropolitan hospital in Brisbane, Australia. Results Over 70% of participants experienced an unplanned admission. Although most participants had access to some form of footwear in hospital (92%), nearly all reported ambulating in footwear with 'suboptimal' features (99%). Examples included slippers (27%), backless slippers (16%) or bare feet (27%). For patients who ambulated in bare feet, only one-third reported 'lack of access to footwear' as the primary cause, with others citing foot wounds, pain, oedema and personal choice as the main reason for bare foot ambulation. Conclusions Admitted patients frequently use footwear with 'suboptimal' features for ambulation in hospital. While some footwear options (for example well-fitting slippers) could be suited for limited in-hospital ambulation, others are clearly hazardous and might cause falls. Since footwear choices are influenced by multiple factors in this population, footwear education strategies alone may be insufficient to address the problem of hazardous footwear in at-risk patients. Footwear requirements may be more effectively addressed within a multidisciplinary team approach encompassing foot health, mobility and safety. What is known about the topic? Accidental falls while ambulating are an important health and safety concern for older people. Because certain footwear characteristics have been negatively linked to posture and balance, and specific footwear types linked to falls among seniors, the use of footwear with fewer suboptimal characteristics is generally recommended as a means of reducing the risk of falling. While footwear

  12. Indicators of suboptimal performance embedded in the Wechsler Memory Scale-Fourth Edition (WMS-IV)

    NARCIS (Netherlands)

    Bouman, Z.; Hendriks, M.P.H.; Schmand, B.A.; Kessels, R.P.C.; Aldenkamp, A.P.

    2016-01-01

    INTRODUCTION: Recognition and visual working memory tasks from the Wechsler Memory Scale-Fourth Edition (WMS-IV) have previously been documented as useful indicators for suboptimal performance. The present study examined the clinical utility of the Dutch version of the WMS-IV (WMS-IV-NL) for the

  13. Indicators of suboptimal performance embedded in the Wechsler Memory Scale-Fourth Edition (WMS-IV)

    NARCIS (Netherlands)

    Bouman, Zita; Hendriks, Marc P. H.; Schmand, Ben A.; Kessels, Roy P. C.; Aldenkamp, Albert P.

    2016-01-01

    Recognition and visual working memory tasks from the Wechsler Memory Scale-Fourth Edition (WMS-IV) have previously been documented as useful indicators for suboptimal performance. The present study examined the clinical utility of the Dutch version of the WMS-IV (WMS-IV-NL) for the identification of

  14. Indicators of suboptimal performance embedded in the Wechsler Memory Scale : Fourth Edition (WMS-IV)

    NARCIS (Netherlands)

    Bouman, Z.; Hendriks, M.P.H.; Schmand, B.A.; Kessels, R.P.C.; Aldenkamp, A.P.

    2016-01-01

    INTRODUCTION: Recognition and visual working memory tasks from the Wechsler Memory Scale-Fourth Edition (WMS-IV) have previously been documented as useful indicators for suboptimal performance. The present study examined the clinical utility of the Dutch version of the WMS-IV (WMS-IV-NL) for the

  15. Indicators of suboptimal performance embedded in the Wechsler Memory Scale-Fourth Edition (WMS-IV)

    NARCIS (Netherlands)

    Bouman, Zita; Hendriks, Marc P.H.; Schmand, Ben A.; Kessels, Roy P.C.; Aldenkamp, Albert P.

    2016-01-01

    Introduction. Recognition and visual working memory tasks from the Wechsler Memory Scale-Fourth Edition (WMS-IV) have previously been documented as useful indicators for suboptimal performance. The present study examined the clinical utility of the Dutch version of the WMS-IV (WMS-IV-NL) for the

  16. An evaluation of the impact of digital imaging on radiographic practice and patient doses

    Science.gov (United States)

    Horrocks, J.; Violaki, K.

    2015-09-01

    Direct digital imaging technology was implemented in all areas in general and mobile radiology at Barts and the Royal London Hospitals in 2012. Evidence from recent radiation incident investigations indicates optimum exposure factors are not consistently selected, with the greater dynamic range of the digital detectors allowing sub-optimal practice. To investigate further patient dose data were extracted from the Radiology Information System for adult chest X-ray examinations in 2014, covering over 50,000 studies in the Trust. Chest X-ray examinations were selected as they are low dose but frequent examinations. The patient dose data were evaluated taking into account X-ray system type and detector performance measurements, and individual cases studies were used to highlight where practice can be improved.

  17. Quantifying Unnecessary Normal Tissue Complication Risks due to Suboptimal Planning: A Secondary Study of RTOG 0126

    International Nuclear Information System (INIS)

    Moore, Kevin L.; Schmidt, Rachel; Moiseenko, Vitali; Olsen, Lindsey A.; Tan, Jun; Xiao, Ying; Galvin, James; Pugh, Stephanie; Seider, Michael J.; Dicker, Adam P.; Bosch, Walter; Michalski, Jeff; Mutic, Sasa

    2015-01-01

    Purpose: The purpose of this study was to quantify the frequency and clinical severity of quality deficiencies in intensity modulated radiation therapy (IMRT) planning in the Radiation Therapy Oncology Group 0126 protocol. Methods and Materials: A total of 219 IMRT patients from the high-dose arm (79.2 Gy) of RTOG 0126 were analyzed. To quantify plan quality, we used established knowledge-based methods for patient-specific dose-volume histogram (DVH) prediction of organs at risk and a Lyman-Kutcher-Burman (LKB) model for grade ≥2 rectal complications to convert DVHs into normal tissue complication probabilities (NTCPs). The LKB model was validated by fitting dose-response parameters relative to observed toxicities. The 90th percentile (22 of 219) of plans with the lowest excess risk (difference between clinical and model-predicted NTCP) were used to create a model for the presumed best practices in the protocol (pDVH 0126,top10% ). Applying the resultant model to the entire sample enabled comparisons between DVHs that patients could have received to DVHs they actually received. Excess risk quantified the clinical impact of suboptimal planning. Accuracy of pDVH predictions was validated by replanning 30 of 219 patients (13.7%), including equal numbers of presumed “high-quality,” “low-quality,” and randomly sampled plans. NTCP-predicted toxicities were compared to adverse events on protocol. Results: Existing models showed that bladder-sparing variations were less prevalent than rectum quality variations and that increased rectal sparing was not correlated with target metrics (dose received by 98% and 2% of the PTV, respectively). Observed toxicities were consistent with current LKB parameters. Converting DVH and pDVH 0126,top10% to rectal NTCPs, we observed 94 of 219 patients (42.9%) with ≥5% excess risk, 20 of 219 patients (9.1%) with ≥10% excess risk, and 2 of 219 patients (0.9%) with ≥15% excess risk. Replanning demonstrated the predicted NTCP

  18. Quantifying Unnecessary Normal Tissue Complication Risks due to Suboptimal Planning: A Secondary Study of RTOG 0126.

    Science.gov (United States)

    Moore, Kevin L; Schmidt, Rachel; Moiseenko, Vitali; Olsen, Lindsey A; Tan, Jun; Xiao, Ying; Galvin, James; Pugh, Stephanie; Seider, Michael J; Dicker, Adam P; Bosch, Walter; Michalski, Jeff; Mutic, Sasa

    2015-06-01

    The purpose of this study was to quantify the frequency and clinical severity of quality deficiencies in intensity modulated radiation therapy (IMRT) planning in the Radiation Therapy Oncology Group 0126 protocol. A total of 219 IMRT patients from the high-dose arm (79.2 Gy) of RTOG 0126 were analyzed. To quantify plan quality, we used established knowledge-based methods for patient-specific dose-volume histogram (DVH) prediction of organs at risk and a Lyman-Kutcher-Burman (LKB) model for grade ≥2 rectal complications to convert DVHs into normal tissue complication probabilities (NTCPs). The LKB model was validated by fitting dose-response parameters relative to observed toxicities. The 90th percentile (22 of 219) of plans with the lowest excess risk (difference between clinical and model-predicted NTCP) were used to create a model for the presumed best practices in the protocol (pDVH0126,top10%). Applying the resultant model to the entire sample enabled comparisons between DVHs that patients could have received to DVHs they actually received. Excess risk quantified the clinical impact of suboptimal planning. Accuracy of pDVH predictions was validated by replanning 30 of 219 patients (13.7%), including equal numbers of presumed "high-quality," "low-quality," and randomly sampled plans. NTCP-predicted toxicities were compared to adverse events on protocol. Existing models showed that bladder-sparing variations were less prevalent than rectum quality variations and that increased rectal sparing was not correlated with target metrics (dose received by 98% and 2% of the PTV, respectively). Observed toxicities were consistent with current LKB parameters. Converting DVH and pDVH0126,top10% to rectal NTCPs, we observed 94 of 219 patients (42.9%) with ≥5% excess risk, 20 of 219 patients (9.1%) with ≥10% excess risk, and 2 of 219 patients (0.9%) with ≥15% excess risk. Replanning demonstrated the predicted NTCP reductions while maintaining the volume of the PTV

  19. Risk-Based Maintenance Assessment in the Manufacturing Industry: Minimisation of Suboptimal Prioritisation

    Directory of Open Access Journals (Sweden)

    Ratnayake R.M. Chandima

    2017-03-01

    Full Text Available Manufacturing firms continuously strive to increase the efficiency and effectiveness in the maintenance management processes. Focus is placed on eliminating the unexpected failures which cause unnecessary costs and the production losses. Risk-based maintenance (RBM strategies enable to address the above through the identification of probability and consequences of potential failures whilst providing a way for prioritisation of maintenance actions based on the risk of possible failures. Such prioritisations enable to identify the optimal maintenance strategy, intervals of maintenance tasks, and optimal level of spare parts inventory. However, the risk assessment activities are performed with the support of a risk matrix. Suboptimal classifications and/or prioritisations arise due to the inherent nature of the risk matrix. This is caused by the fact that there are no means to incorporate actual circumstances at the boundary of the input ranges or at the levels of linguistic data and risk categories. In this paper, a risk matrix is first developed in collaboration with one of the manufacturing firms in Poland. Then, it illustrates the use of fuzzy logic for minimisation of suboptimal prioritisation and/or classifications using a fuzzy inference system (FIS together with illustrative membership functions and a rule base. Finally, an illustrative risk assessment is also demonstrated to illustrate the methodology.

  20. High T-cell immune activation and immune exhaustion among individuals with suboptimal CD4 recovery after 4 years of antiretroviral therapy in an African cohort

    Directory of Open Access Journals (Sweden)

    Colebunders Robert

    2011-02-01

    Full Text Available Abstract Background Antiretroviral therapy (ART partially corrects immune dysfunction associated with HIV infection. The levels of T-cell immune activation and exhaustion after long-term, suppressive ART and their correlation with CD4 T-cell count reconstitution among ART-treated patients in African cohorts have not been extensively evaluated. Methods T-cell activation (CD38+HLA-DR+ and immune exhaustion (PD-1+ were measured in a prospective cohort of patients initiated on ART; 128 patient samples were evaluated and subcategorized by CD4 reconstitution after long-term suppressive treatment: Suboptimal [median CD4 count increase 129 (-43-199 cells/μl], N = 34 ], optimal [282 (200-415 cells/μl, N = 64] and super-optimal [528 (416-878 cells/μl, N = 30]. Results Both CD4+ and CD8 T-cell activation was significantly higher among suboptimal CD4 T-cell responders compared to super-optimal responders. In a multivariate model, CD4+CD38+HLADR+ T-cells were associated with suboptimal CD4 reconstitution [AOR, 5.7 (95% CI, 1.4-23, P = 0.014]. T-cell exhaustion (CD4+PD1+ and CD8+PD1+ was higher among suboptimal relative to optimal (P P = 0.022]. Conclusion T-cell activation and exhaustion persist among HIV-infected patients despite long-term, sustained HIV-RNA viral suppression. These immune abnormalities were associated with suboptimal CD4 reconstitution and their regulation may modify immune recovery among suboptimal responders to ART.

  1. A PROCEDURE FOR DETERMINING OPTIMAL FACILITY LOCATION AND SUB-OPTIMAL POSITIONS

    Directory of Open Access Journals (Sweden)

    P.K. Dan

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: This research presents a methodology for determining the optimal location of a new facility, having physical flow interaction of various degrees with other existing facilities in the presence of barriers impeding the shortest flow-path as well as the sub-optimal iso-cost positions. It also determines sub-optimal iso-cost positions with additional cost or penalty for not being able to site it at the computed optimal point. The proposed methodology considers all types of quadrilateral barrier or forbidden region configurations to generalize and by-pass such impenetrable obstacles, and adopts a scheme of searching through the vertices of the quadrilaterals to determine the alternative shortest flow-path. This procedure of obstacle avoidance is novel. Software has been developed to facilitate computations for the search algorithm to determine the optimal and iso-cost co-ordinates. The test results are presented.

    AFRIKAANSE OPSOMMING: Die navorsing behandel ‘n procedure vir die bepaling van optimum stigtingsposisie vir ‘n onderneming met vloei vanaf ander bestaande fasiliteite in die teenwoordigheid van ‘n verskeidenheid van randvoorwaardes. Die prodedure lewer as resultaat suboptimale isokoste-stigtingsplekke met bekendmaking van die koste wat onstaan a.g.v. afwyking van die randvoorwaardlose optimum oplossingskoste, die prosedure maak gebruik van ‘n vindingryke soekmetode wat toegepas word op niersydige meerkundige voorstellings vir die bepaling van korste roetes wat versperring omseil. Die prosedure word onderskei deur programmatuur. Toetsresultate word voorgehou.

  2. A Suboptimal Scheme for Multi-User Scheduling in Gaussian Broadcast Channels

    KAUST Repository

    Zafar, Ammar; Alouini, Mohamed-Slim; Shaqfeh, Mohammad

    2014-01-01

    This work proposes a suboptimal multi-user scheduling scheme for Gaussian broadcast channels which improves upon the classical single user selection, while considerably reducing complexity as compared to the optimal superposition coding with successful interference cancellation. The proposed scheme combines the two users with the maximum weighted instantaneous rate using superposition coding. The instantaneous rate and power allocation are derived in closed-form, while the long term rate of each user is derived in integral form for all channel distributions. Numerical results are then provided to characterize the prospected gains of the proposed scheme.

  3. A Suboptimal Scheme for Multi-User Scheduling in Gaussian Broadcast Channels

    KAUST Repository

    Zafar, Ammar

    2014-05-28

    This work proposes a suboptimal multi-user scheduling scheme for Gaussian broadcast channels which improves upon the classical single user selection, while considerably reducing complexity as compared to the optimal superposition coding with successful interference cancellation. The proposed scheme combines the two users with the maximum weighted instantaneous rate using superposition coding. The instantaneous rate and power allocation are derived in closed-form, while the long term rate of each user is derived in integral form for all channel distributions. Numerical results are then provided to characterize the prospected gains of the proposed scheme.

  4. Suboptimal and optimal order policies for fixed and varying replenishment interval with declining market

    Science.gov (United States)

    Yu, Jonas C. P.; Wee, H. M.; Yang, P. C.; Wu, Simon

    2016-06-01

    One of the supply chain risks for hi-tech products is the result of rapid technological innovation; it results in a significant decline in the selling price and demand after the initial launch period. Hi-tech products include computers and communication consumer's products. From a practical standpoint, a more realistic replenishment policy is needed to consider the impact of risks; especially when some portions of shortages are lost. In this paper, suboptimal and optimal order policies with partial backordering are developed for a buyer when the component cost, the selling price, and the demand rate decline at a continuous rate. Two mathematical models are derived and discussed: one model has the suboptimal solution with the fixed replenishment interval and a simpler computational process; the other one has the optimal solution with the varying replenishment interval and a more complicated computational process. The second model results in more profit. Numerical examples are provided to illustrate the two replenishment models. Sensitivity analysis is carried out to investigate the relationship between the parameters and the net profit.

  5. Consumer behaviour towards price-reduced suboptimal foods in the supermarket and the relation to food waste in households.

    Science.gov (United States)

    Aschemann-Witzel, Jessica; Jensen, Jacob Haagen; Jensen, Mette Hyldetoft; Kulikovskaja, Viktorija

    2017-09-01

    To combat food waste, supermarkets offer food items at a reduced price in-store when they are close to the expiration date or perceived as suboptimal. It is yet unknown, however, which considerations consumers engage in when deciding about the offer, and whether focusing particularly on the price during food purchase might be related to greater food waste at home. Knowledge about both the consumers' food purchase process for these price-reduced foods and the potential wastage of price-focused consumers can contribute to the assessment of whether or not offering suboptimal food at reduced prices in-store actually reduces food waste across the supply chain. We explore these questions in a mixed-method study including 16 qualitative accompanied shopping interviews and a quantitative online experimental survey with 848 consumers in Denmark. The interviews reveal that the consumers interviewed assess their ability to consume the price-reduced suboptimal food at home already while in the store. Consumers consider the relation between product-related factors of package unit, expiration date, and product quality, in interaction with household-related factors of freezing/storing, household size/demand, and possible meal/cooking. The survey shows that consumers who are more price-focused report lower food waste levels and lower tendency to choose the optimal food item first at home, than those who are not emphasizing the price-quality relation or do not search for price offers to the same extent. Higher age and high education also played a role, and the price-focus is lower in high-income groups and among single households. The findings allow deriving recommendations for retailers and policy makers to support both the marketability and the subsequent actual consumption of price-reduced suboptimal food, but they also raise questions for further research of this underexplored area. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Effect of sub-optimal doses of fluoxetine plus estradiol on antidepressant-like behavior and hippocampal neurogenesis in ovariectomized rats.

    Science.gov (United States)

    Vega-Rivera, Nelly M; Fernández-Guasti, Alonso; Ramírez-Rodríguez, Gerardo; Estrada-Camarena, Erika

    2015-07-01

    Estrogens and antidepressants synergize to reduce depressive symptoms and stimulate neurogenesis and neuroplastic events. The aim of this study was to explore whether the antidepressant-like effect induced by the combination of low doses of estradiol (E2) and fluoxetine (FLX) involves changes in cell proliferation, early survival, morphology and dendrite complexity of hippocampal new-immature neurons. The antidepressant-like effects of E2 and/or FLX were evaluated by the forced swimming test (FST), cell proliferation was determined with the endogenous marker Ki67, survival of newborn cells was established with bromo-deoxiuridine (BrdU) and immature neurons were ascertained by doublecortin (DCX) labeling while their dendrite complexity was evaluated with Sholl analysis. Ovariectomized Wistar rats were randomly assigned to one of the following groups: Vehicle (saline/14 days+Oil/-8h before FST); E2 (saline/14 days + E2 2.5 or 10 μg/rat; -8 h before FST); FLX (1.25 or 10 mg/kg for 14 days + oil -8h before FST), and FLX plus E2 (FLX 1.25 mg/kg for 14 days + E2 2.5 μg/rat -8 h before FST). The combination of sub-threshold doses of FLX plus E2 produced antidepressant-like actions similar to those induced by FLX or E2 given independently at optimal doses. Only FLX at an optimal dose and the combination of FLX plus E2 increased cell proliferation, the number of DCX-labeled immature neurons and the complexity of their dendritic tree, suggesting that these events may be responsible for their antidepressant-like effect. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Suboptimal care and maternal mortality among foreign-born women in Sweden: maternal death audit with application of the 'migration three delays' model.

    Science.gov (United States)

    Esscher, Annika; Binder-Finnema, Pauline; Bødker, Birgit; Högberg, Ulf; Mulic-Lutvica, Ajlana; Essén, Birgitta

    2014-04-12

    Several European countries report differences in risk of maternal mortality between immigrants from low- and middle-income countries and host country women. The present study identified suboptimal factors related to care-seeking, accessibility, and quality of care for maternal deaths that occurred in Sweden from 1988-2010. A subset of maternal death records (n = 75) among foreign-born women from low- and middle-income countries and Swedish-born women were audited using structured implicit review. One case of foreign-born maternal death was matched with two native born Swedish cases of maternal death. An assessment protocol was developed that applied both the 'migration three delays' framework and a modified version of the Confidential Enquiry from the United Kingdom. The main outcomes were major and minor suboptimal factors associated with maternal death in this high-income, low-maternal mortality context. Major and minor suboptimal factors were associated with a majority of maternal deaths and significantly more often to foreign-born women (p = 0.01). The main delays to care-seeking were non-compliance among foreign-born women and communication barriers, such as incongruent language and suboptimal interpreter system or usage. Inadequate care occurred more often among the foreign-born (p = 0.04), whereas delays in consultation/referral and miscommunication between health care providers where equally common between the two groups. Suboptimal care factors, major and minor, were present in more than 2/3 of maternal deaths in this high-income setting. Those related to migration were associated to miscommunication, lack of professional interpreters, and limited knowledge about rare diseases and pregnancy complications. Increased insight into a migration perspective is advocated for maternity clinicians who provide care to foreign-born women.

  8. Exogenous recombinant human growth hormone effects during suboptimal energy and zinc intake

    OpenAIRE

    Rising, Russell; Scaglia, Julio F; Cole, Conrad; Tverskaya, Rozalia; Duro, Debora; Lifshitz, Fima

    2005-01-01

    Abstract Background Energy and Zinc (Zn) deficiencies have been associated with nutritional related growth retardation as well as growth hormone (GH) resistance. In this study, the relationship between suboptimal energy and/or Zn intake and growth in rats and their response to immunoreactive exogenous recombinant human GH (GHi), was determined. Results Rats treated with GHi and fed ad-libitum energy and Zn (100/100) had increased IGFBP-3 (p < 0.05) as compared with NSS (215 ± 23 vs. 185 ± 17 ...

  9. Socioeconomic factors explain suboptimal adherence to antiretroviral therapy among HIV-infected Australian adults with viral suppression

    NARCIS (Netherlands)

    Siefried, Krista J; Mao, Limin; Kerr, Stephen; Cysique, Lucette A; Gates, Thomas M; McAllister, John; Maynard, Anthony; de Wit, John; Carr, Andrew

    2017-01-01

    BACKGROUND: Missing more than one tablet of contemporary antiretroviral therapy (ART) per month increases the risk of virological failure. Recent studies evaluating a comprehensive range of potential risk factors for suboptimal adherence are not available for high-income settings. METHODS: Adults on

  10. Sub-optimal parenting is associated with schizotypic and anxiety personality traits in adulthood.

    Science.gov (United States)

    Giakoumaki, S G; Roussos, P; Zouraraki, C; Spanoudakis, E; Mavrikaki, M; Tsapakis, E M; Bitsios, P

    2013-05-01

    Part of the variation in personality characteristics has been attributed to the child-parent interaction and sub-optimal parenting has been associated with psychiatric morbidity. In the present study, an extensive battery of personality scales (Trait Anxiety Inventory, Behavioural Inhibition/Activation System questionnaire, Eysenck Personality Questionnaire-Revised, Temperament and Character Inventory, Schizotypal Traits Questionnaire, Toronto Alexithymia Scale) and the Parental Bonding Instrument (PBI) were administered in 324 adult healthy males to elucidate the effects of parenting on personality configuration. Personality variables were analysed using Principal Component Analysis (PCA) and the factors "Schizotypy", "Anxiety", "Behavioural activation", "Novelty seeking" and "Reward dependence" were extracted. Associations between personality factors with PBI "care" and "overprotection" scores were examined with regression analyses. Subjects were divided into "parental style" groups and personality factors were subjected to categorical analyses. "Schizotypy" and "Anxiety" were significantly predicted by high maternal overprotection and low paternal care. In addition, the Affectionless control group (low care/high overprotection) had higher "Schizotypy" and "Anxiety" compared with the Optimal Parenting group (high care/low overprotection). These results further validate sub-optimal parenting as an important environmental exposure and extend our understanding on the mechanisms by which it increases risk for psychiatric morbidity. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  11. Knowledge-based prediction of three-dimensional dose distributions for external beam radiotherapy

    International Nuclear Information System (INIS)

    Shiraishi, Satomi; Moore, Kevin L.

    2016-01-01

    Purpose: To demonstrate knowledge-based 3D dose prediction for external beam radiotherapy. Methods: Using previously treated plans as training data, an artificial neural network (ANN) was trained to predict a dose matrix based on patient-specific geometric and planning parameters, such as the closest distance (r) to planning target volume (PTV) and organ-at-risks (OARs). Twenty-three prostate and 43 stereotactic radiosurgery/radiotherapy (SRS/SRT) cases with at least one nearby OAR were studied. All were planned with volumetric-modulated arc therapy to prescription doses of 81 Gy for prostate and 12–30 Gy for SRS. Using these clinically approved plans, ANNs were trained to predict dose matrix and the predictive accuracy was evaluated using the dose difference between the clinical plan and prediction, δD = D clin − D pred . The mean (〈δD r 〉), standard deviation (σ δD r ), and their interquartile range (IQR) for the training plans were evaluated at a 2–3 mm interval from the PTV boundary (r PTV ) to assess prediction bias and precision. Initially, unfiltered models which were trained using all plans in the cohorts were created for each treatment site. The models predict approximately the average quality of OAR sparing. Emphasizing a subset of plans that exhibited superior to the average OAR sparing during training, refined models were created to predict high-quality rectum sparing for prostate and brainstem sparing for SRS. Using the refined model, potentially suboptimal plans were identified where the model predicted further sparing of the OARs was achievable. Replans were performed to test if the OAR sparing could be improved as predicted by the model. Results: The refined models demonstrated highly accurate dose distribution prediction. For prostate cases, the average prediction bias for all voxels irrespective of organ delineation ranged from −1% to 0% with maximum IQR of 3% over r PTV ∈ [ − 6, 30] mm. The average prediction error was less

  12. A dose-effect correlation for radioiodine ablation in differentiated thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Flux, Glenn D; Chittenden, Sarah J; Buckley, Susan; Hindorf, Cecilia [Royal Marsden NHS Foundation Trust, Department of Physics, Sutton, Surrey (United Kingdom); Haq, Masud; Newbold, Kate; Harmer, Clive L [Royal Marsden NHS Foundation Trust, Thyroid Unit, Sutton, Surrey (United Kingdom)

    2010-02-15

    The aim of this study was to determine the range of absorbed doses delivered to thyroid remnants, blood, and red marrow from fixed administrations of radioiodine and to ascertain whether the success of ablation is more dependent on these absorbed doses than on the administered activity. Twenty-three patients received 3,000 MBq radioiodine following near-total thyroidectomy. The maximum absorbed dose to remnants was calculated from subsequent single photon emission tomography scans. Absorbed doses delivered to blood and red marrow were calculated from blood samples and from whole-body retention measurements. The protein bound iodine (PBI) was also calculated. Maximum absorbed doses to thyroid remnants ranged from 7 to 570 Gy. Eighteen of the 23 patients had a successful ablation. A significant difference was seen between the absorbed doses delivered to thyroid remnants, blood, and red marrow for those patients that had a successful ablation compared to those with a failed ablation (p = 0.030, p = 0.043 and p = 0.048, respectively). The difference between the PBI values acquired at day 1 and day 6 were also indicative of response (p = 0.074). A successful ablation is strongly dependent on the absorbed dose to the thyroid remnant. Dosimetry-based personalized treatment can prevent both sub-optimal administrations, which entails further radioiodine therapy, and excessive administration of radioactivity, which increases the potential for radiation toxicity. (orig.)

  13. Common experiences of patients following suboptimal treatment outcomes: implications for epilepsy surgery.

    Science.gov (United States)

    Fernando, Dinusha K; McIntosh, Anne M; Bladin, Peter F; Wilson, Sarah J

    2014-04-01

    Few studies have investigated the patient experience of unsuccessful medical interventions, particularly in the epilepsy surgery field. The present review aimed to gain insight into the patient experience of seizure recurrence after epilepsy surgery by examining the broader literature dealing with suboptimal results after medical interventions (including epilepsy surgery). To capture the patient experience, the literature search focused on qualitative research of patients who had undergone medically unsuccessful interventions, published in English in scholarly journals. Twenty-two studies were found of patients experiencing a range of suboptimal outcomes, including seizure recurrence, cancer recurrence and progression, unsuccessful joint replacement, unsuccessful infertility treatment, organ transplant rejection, coronary bypass graft surgery, and unsuccessful weight-loss surgery. In order of frequency, the most common patient experiences included the following: altered social dynamics and stigma, unmet expectations, negative emotions, use of coping strategies, hope and optimism, perceived failure of the treating team, psychiatric symptoms, and control issues. There is support in the epilepsy surgery literature that unmet expectations and psychiatric symptoms are key issues for patients with seizure recurrence, while other common patient experiences have been implied but not systematically examined. Several epilepsy surgery specific factors influence patient perceptions of seizure recurrence, including the nature of postoperative seizures, the presence of postoperative complications, and the need for increased postoperative medications. Knowledge of common patient experiences can assist in the delivery of patient follow-up and rehabilitation services tailored to differing outcomes after epilepsy surgery. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Association of Suboptimal Antiretroviral Therapy Adherence With Inflammation in Virologically Suppressed Individuals Enrolled in the SMART Study

    DEFF Research Database (Denmark)

    Castillo-Mancilla, Jose R; Phillips, Andrew N; Neaton, James D

    2018-01-01

    Suboptimal (ie, <100%) antiretroviral therapy (ART) adherence has been associated with heightened inflammation in cohort studies, even among people with virologic suppression. We aimed to evaluate this association among participants in the Strategies for Management of Antiretroviral Therapy (SMAR...

  15. Optimisation of antimicrobial dosing based on pharmacokinetic and pharmacodynamic principles

    Directory of Open Access Journals (Sweden)

    Grace Si Ru Hoo

    2017-01-01

    Full Text Available While suboptimal dosing of antimicrobials has been attributed to poorer clinical outcomes, clinical cure and mortality advantages have been demonstrated when target pharmacokinetic (PK and pharmacodynamic (PD indices for various classes of antimicrobials were achieved to maximise antibiotic activity. Dosing optimisation requires a good knowledge of PK/PD principles. This review serves to provide a foundation in PK/PD principles for the commonly prescribed antibiotics (β-lactams, vancomycin, fluoroquinolones and aminoglycosides, as well as dosing considerations in special populations (critically ill and obese patients. PK principles determine whether an appropriate dose of antimicrobial reaches the intended pathogen(s. It involves the fundamental processes of absorption, distribution, metabolism and elimination, and is affected by the antimicrobial's physicochemical properties. Antimicrobial pharmacodynamics define the relationship between the drug concentration and its observed effect on the pathogen. The major indicator of the effect of the antibiotics is the minimum inhibitory concentration. The quantitative relationship between a PK and microbiological parameter is known as a PK/PD index, which describes the relationship between dose administered and the rate and extent of bacterial killing. Improvements in clinical outcomes have been observed when antimicrobial agents are dosed optimally to achieve their respective PK/PD targets. With the rising rates of antimicrobial resistance and a limited drug development pipeline, PK/PD concepts can foster more rational and individualised dosing regimens, improving outcomes while simultaneously limiting the toxicity of antimicrobials.

  16. Dose-dependent social-cognitive effects of intranasal oxytocin delivered with novel Breath Powered device in adults with autism spectrum disorder: a randomized placebo-controlled double-blind crossover trial

    OpenAIRE

    Quintana, D S; Westlye, L T; Hope, S; N?rland, T; Elvs?shagen, T; D?rum, E; Rustan, ?; Valstad, M; Rezvaya, L; Lishaugen, H; Stens?nes, E; Yaqub, S; Smerud, K T; Mahmoud, R A; Djupesland, P G

    2017-01-01

    The neuropeptide oxytocin has shown promise as a treatment for symptoms of autism spectrum disorders (ASD). However, clinical research progress has been hampered by a poor understanding of oxytocin?s dose?response and sub-optimal intranasal delivery methods. We examined two doses of oxytocin delivered using a novel Breath Powered intranasal delivery device designed to improve direct nose-to-brain activity in a double-blind, crossover, randomized, placebo-controlled trial. In a randomized sequ...

  17. Consumer perception and preference for suboptimal food under the emerging practice of expiration date based pricing in supermarkets

    DEFF Research Database (Denmark)

    Aschemann-Witzel, Jessica

    2017-01-01

    , it is unclear which contextual, individual, and product-related factors impact consumer likelihood of choice and thus acceptance of the practice in the long run. The study aimed at exploring the effect of communicating different motives for purchase, the product being organic, familiarity with the practice...... and the interaction with gender is observed for milk in particular. Overall, perceived quality and estimated likelihood of consumption at home majorly determine likelihood of choice. Consumer acceptance of expiration date based pricing of suboptimal food can be increased through furthering consumer familiarity......Consumers have been found to majorly prefer ‘optimal’ food over ‘suboptimal’ when purchasing food. To provide an incentive for consumers to select suboptimal food and thus decrease food waste in the supply chain, expiration date based pricing is suggested and increasingly applied. However...

  18. Failure Rate of Single Dose Methotrexate in Managment of Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Feras Sendy

    2015-01-01

    Full Text Available Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67% received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225 of the patients. 28% (63/225 were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63 of failure received a second dose of methotrexate, and 37% (23/63 underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate.

  19. Failure rate of single dose methotrexate in managment of ectopic pregnancy.

    Science.gov (United States)

    Sendy, Feras; AlShehri, Eman; AlAjmi, Amani; Bamanie, Elham; Appani, Surekha; Shams, Taghreed

    2015-01-01

    Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67%)) received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225) of the patients. 28% (63/225) were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63) of failure received a second dose of methotrexate, and 37% (23/63) underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate.

  20. Methanol degradation in granular sludge reactors at sub-optimal metal concentrations: role of iron, nickel and cobalt

    NARCIS (Netherlands)

    Zandvoort, M.H.; Geerts, R.; Lettinga, G.; Lens, P.N.L.

    2003-01-01

    The effect of sub-optimal trace metal concentrations on the conversion of methanol in an upflow anaerobic sludge bed (UASB) reactor was investigated by studying the effect of decreased influent trace metal concentrations on the reactor efficiency, methanol conversion route and sludge

  1. Influence of Flat-Panel Fluoroscopic Equipment Variables on Cardiac Radiation Doses

    International Nuclear Information System (INIS)

    Nickoloff, Edward L.; Lu Zhengfeng; Dutta, Ajoy; So, James; Balter, Stephen; Moses, Jeffrey

    2007-01-01

    Purpose. To assess the influence of physician-selectable equipment variables on the potential radiation dose reductions during cardiac catheterization examinations using modern imaging equipment. Materials. A modern bi-plane angiography unit with flat-panel image receptors was used. Patients were simulated with 15-30 cm of acrylic plastic. The variables studied were: patient thickness, fluoroscopy pulse rates, record mode frame rates, image receptor field-of-view (FoV), automatic dose control (ADC) mode, SID/SSD geometry setting, automatic collimation, automatic positioning, and others. Results. Patient radiation doses double for every additional 3.5-4.5 cm of soft tissue. The dose is directly related to the imaging frame rate; a decrease from 30 pps to 15 pps reduces the dose by about 50%. The dose is related to [(FoV) -N ] where 2.0 < N < 3.0. Suboptimal positioning of the patient can nearly double the dose. The ADC system provides three selections that can vary the radiation level by 50%. For pediatric studies (2-5 years old), the selection of equipment variables can result in entrance radiation doses that range between 6 and 60 cGy for diagnostic cases and between 15 and 140 cGy for interventional cases. For adult studies, the equipment variables can produce entrance radiation doses that range between 13 and 130 cGy for diagnostic cases and between 30 and 400 cGy for interventional cases. Conclusions. Overall dose reductions of 70-90% can be achieved with pediatric patients and about 90% with adult patients solely through optimal selection of equipment variables

  2. Segmentation precedes face categorization under suboptimal conditions

    Directory of Open Access Journals (Sweden)

    Carlijn eVan Den Boomen

    2015-05-01

    Full Text Available Both categorization and segmentation processes play a crucial role in face perception. However, the functional relation between these subprocesses is currently unclear. The present study investigates the temporal relation between segmentation-related and category-selective responses in the brain, using electroencephalography (EEG. Surface segmentation and category content were both manipulated using texture-defined objects, including faces. This allowed us to study brain activity related to segmentation and to categorization. In the main experiment, participants viewed texture-defined objects for a duration of 800 ms. EEG results revealed that segmentation-related responses precede category-selective responses. Three additional experiments revealed that the presence and timing of categorization depends on stimulus properties and presentation duration. Photographic objects were presented for a long and short (92 ms duration and evoked fast category-selective responses in both cases. On the other hand, presentation of texture-defined objects for a short duration only evoked segmentation-related but no category-selective responses. Category-selective responses were much slower when evoked by texture-defined than by photographic objects. We suggest that in case of categorization of objects under suboptimal conditions, such as when low-level stimulus properties are not sufficient for fast object categorization, segmentation facilitates the slower categorization process.

  3. Segmentation precedes face categorization under suboptimal conditions.

    Science.gov (United States)

    Van Den Boomen, Carlijn; Fahrenfort, Johannes J; Snijders, Tineke M; Kemner, Chantal

    2015-01-01

    Both categorization and segmentation processes play a crucial role in face perception. However, the functional relation between these subprocesses is currently unclear. The present study investigates the temporal relation between segmentation-related and category-selective responses in the brain, using electroencephalography (EEG). Surface segmentation and category content were both manipulated using texture-defined objects, including faces. This allowed us to study brain activity related to segmentation and to categorization. In the main experiment, participants viewed texture-defined objects for a duration of 800 ms. EEG results revealed that segmentation-related responses precede category-selective responses. Three additional experiments revealed that the presence and timing of categorization depends on stimulus properties and presentation duration. Photographic objects were presented for a long and short (92 ms) duration and evoked fast category-selective responses in both cases. On the other hand, presentation of texture-defined objects for a short duration only evoked segmentation-related but no category-selective responses. Category-selective responses were much slower when evoked by texture-defined than by photographic objects. We suggest that in case of categorization of objects under suboptimal conditions, such as when low-level stimulus properties are not sufficient for fast object categorization, segmentation facilitates the slower categorization process.

  4. Real-time discrete suboptimal control for systems with input and state delays: Experimental tests on a dehydration process.

    Science.gov (United States)

    Rodríguez-Guerrero, Liliam; Santos-Sánchez, Omar-Jacobo; Cervantes-Escorcia, Nicolás; Romero, Hugo

    2017-11-01

    This article presents a suboptimal control strategy with finite horizon for affine nonlinear discrete systems with both state and input delays. The Dynamic Programming Approach is used to obtain the suboptimal control sequence, but in order to avoid the computation of the Bellman functional, a numerical approximation of this function is proposed in every step. The feasibility of our proposal is demonstrated via an experimental test on a dehydration process and the obtained results show a good performance and behavior of this process. Then in order to demonstrate the benefits of using this kind of control strategy, the results are compared with a non optimal control strategy, particularly with respect to results produced by an industrial Proportional Integral Derivative (PID) Honeywell controller, which is tuned using the Ziegler-Nichols method. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  5. Knowledge-based prediction of three-dimensional dose distributions for external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Shiraishi, Satomi; Moore, Kevin L., E-mail: kevinmoore@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California 92093 (United States)

    2016-01-15

    Purpose: To demonstrate knowledge-based 3D dose prediction for external beam radiotherapy. Methods: Using previously treated plans as training data, an artificial neural network (ANN) was trained to predict a dose matrix based on patient-specific geometric and planning parameters, such as the closest distance (r) to planning target volume (PTV) and organ-at-risks (OARs). Twenty-three prostate and 43 stereotactic radiosurgery/radiotherapy (SRS/SRT) cases with at least one nearby OAR were studied. All were planned with volumetric-modulated arc therapy to prescription doses of 81 Gy for prostate and 12–30 Gy for SRS. Using these clinically approved plans, ANNs were trained to predict dose matrix and the predictive accuracy was evaluated using the dose difference between the clinical plan and prediction, δD = D{sub clin} − D{sub pred}. The mean (〈δD{sub r}〉), standard deviation (σ{sub δD{sub r}}), and their interquartile range (IQR) for the training plans were evaluated at a 2–3 mm interval from the PTV boundary (r{sub PTV}) to assess prediction bias and precision. Initially, unfiltered models which were trained using all plans in the cohorts were created for each treatment site. The models predict approximately the average quality of OAR sparing. Emphasizing a subset of plans that exhibited superior to the average OAR sparing during training, refined models were created to predict high-quality rectum sparing for prostate and brainstem sparing for SRS. Using the refined model, potentially suboptimal plans were identified where the model predicted further sparing of the OARs was achievable. Replans were performed to test if the OAR sparing could be improved as predicted by the model. Results: The refined models demonstrated highly accurate dose distribution prediction. For prostate cases, the average prediction bias for all voxels irrespective of organ delineation ranged from −1% to 0% with maximum IQR of 3% over r{sub PTV} ∈ [ − 6, 30] mm. The

  6. Sub-optimal breastfeeding of infants during the first six months and associated factors in rural communities of Jimma Arjo Woreda, Southwest Ethiopia

    Directory of Open Access Journals (Sweden)

    Tamiru Dessalegn

    2012-05-01

    Full Text Available Abstract Background Studies have shown that sub-optimal breastfeeding is major contributor to infant and young child mortality in Ethiopia. To address this problem, infant and young child feeding guideline was developed in 2004 and interventions have been going on based on the guidelines. There is no study that assessed whether the infant and child feeding practices are according the guideline or not. This study was carried out to assess sub-optimal breastfeeding practices and associated factors among infants from birth to six months in rural communities of Jimma Arjo Woreda in the Southwest Ethiopia. Methods A cross-sectional study was carried out from December to January 2009. Quantitative data were collected from a sample of 382 respondents supplemented by qualitative data generated using in-depth interviews of 15 index mothers. Multivariable logistic regression model was used to identify predictors of timely initiation of breast feeding and non-exclusive breast feeding among mother-infant pairs. Results More than three fourth of mothers breastfeed their infants sub-optimally. Thirty-seven percent of mothers initiated breastfeeding later than one hour after delivery, which was significantly associated with not attending formal education (AOR = 1.05[95%CI: 1.03, 1.94] and painful breastfeeding experiences (AOR = 5.02[95%CI: 1.01, 10.08]. The majority (67.02% of mothers had no knowledge about exclusive breastfeeding. Non-exclusive breastfeeding was negatively associated with child’s age of 0-2 months (AOR: 0.27[95%CI: 0.16, 0.47 and 3-4 months (AOR = 0.43 [95%CI: 0.25, 0.73 and ownership of radio (AOR = 0.56[95%CI: 0.37, 0.88], but positively associated with the practice of discarding colostrums (AOR = 1.78[95%CI: 1.09, 4.94]. Conclusion The findings showed that the majority of mothers sub-optimally breastfeed their children in the study area. As most of the mothers do not have knowledge on the exclusive breast feeding. Enhancing community

  7. Embryo transcriptome response to environmental factors: implication for its survival under suboptimal conditions.

    Science.gov (United States)

    Salilew-Wondim, Dessie; Tesfaye, Dawit; Hoelker, Michael; Schellander, Karl

    2014-09-01

    After its formation, the mammalian zygote undergoes a series of morphological, physiological and biochemical alterations prior to undergoing cell differentiation. The zygote is then transformed into a complex multicellular organism in a defined time window which may differ between species. These orderly embryonic developmental events are tightly regulated by temporal and spatial activation and/or deactivation of genes and gene products. This phenomenon may in turn be dependent on the intrinsic characteristics of the embryo itself, the physiological and biochemical composition of the maternal environment or by in vitro culture condition. In fact, when embryos are subjected to suboptimal culture condition, some of the embryos may escape the environmental stress by activating certain transcripts and some others which are unable to activate anti-stress agents may die or exhibit abnormal development. This phenomenon may partly depend on transcripts and proteins stored during oogenesis. Indeed after embryonic genome activation, the embryo destiny is governed by its own transcripts and protein synthesized over time. Therefore, this review begins by highlighting the type and quality of transcripts accumulated or degraded during oogenesis and its impact on the embryo survival. Thereafter, emphasis is given to the transcriptome response of preimplantation embryos to suboptimal culture conditions. In addition, the long term effect of preimplantation culture environment on the transcriptome response embryos/fetus during peri and post implantation has been addressed. Finally, a brief summary of the epigenetic control of culture induced genetic variation of the embryos has been highlighted. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Suboptimal etravirine activity is common during failure of nevirapine-based combination antiretroviral therapy in a cohort infected with non-B subtype HIV-1.

    Science.gov (United States)

    Taiwo, Babafemi; Chaplin, Beth; Penugonda, Sudhir; Meloni, Seema; Akanmu, Sulaimon; Gashau, Wadzani; Idoko, John; Adewole, Isaac; Murphy, Robert; Kanki, Phyllis

    2010-04-01

    The primary objective of this study was to estimate etravirine activity in a cohort of patients infected with non-B subtype HIV-1 and failing nevirapine-based therapy. Genotypic resistance testing was performed if viral load was >OR= 1,000 copies/ml after receiving at least six months of therapy. Suboptimal response to etravirine was predicted by a score >OR= 2.5 on the Tibotec weighting schema, >OR= 4 in the Monogram schema, or classification as high to low-level resistant by a modification of the Stanford HIVdb algorithm (Version 5.1.2). Bivariate and multivariate analyses were conducted to determine the risk factors for suboptimal etravirine activity. The patients (n=91) were receiving nevirapine and lamivudine plus stavudine (57.1%) or zidovudine (42.9%). Median duration of nevirapine exposure was 53 weeks (IQR 46-101 weeks). The most common etravirine resistance associated mutations were Y181C (42.9%), G190A (25.3%), H221Y (19.8%), A98G (18.7%), K101E (16.5%), and V90I (12.1%). Suboptimal etravirine activity was predicted in 47.3 to 56.0%. There were disparities in mutations listed in Tibotec versus Monogram Schemas. Predicted suboptimal activity was not associated with nucleoside reverse transcriptase inhibitor (NRTI) used, gender, pretreatment or current CD4 cell count or viral load, subtype or NRTI mutations. Etravirine has compromised activity in approximately half of the patients failing nevirapine-based first-line treatment in this cohort, which supports guidelines that caution against using it with NRTIs alone in such patients.

  9. Energy expenditures & physical activity in rats with chronic suboptimal nutrition

    Directory of Open Access Journals (Sweden)

    Lifshitz Fima

    2006-01-01

    Full Text Available Abstract Background Sub-optimally nourished rats show reduced growth, biochemical and physiological changes. However, no one has assessed metabolic rate adaptations in rats subjected to chronic suboptimal nutrition (CSN. In this study energy expenditure (EE; kcal/100 g body weight and physical activity (PA; oscillations in weight/min/kg body weight were assessed in rats subjected to three levels of CSN. Results Body weight gain was diminished (76.7 ± 12.0 and 61.6 ± 11.0 g in rats fed 70 and 60% of the ad-libitum fed controls which gained more weight (148.5 ± 32.3 g. The rats fed 80% gained weight similarly to controls (136.3 ± 10.5 g. Percent Fat-free body mass was reduced (143.8 ± 8.7 and 142.0 ± 7.6 g in rats fed 70 and 60% of ad-libitum, but not in those fed 80% (200.8 ± 17.5 g as compared with controls (201.6 ± 33.4 g. Body fat (g decreased in rats fed 80% (19.7 ± 5.3, 70% (15.3 ± 3.5 and 60% (9.6 ± 2.7 of ad-libitum in comparison to controls (26.0 ± 6.7. EE and PA were also altered by CSN. The control rats increased their EE and PA during the dark periods by 1.4 ± 0.8 and 1.7 ± 1.1 respectively, as compared with light the period; whereas CSN rats fed 80 and 70% of ad-libitum energy intake had reduced EE and PA during the dark periods as compared with the light period EE(7.5 ± 1.4 and 7.8 ± 0.6 vs. 9.0 ± 1.2 and 9.7 ± 0.8; p Conclusion CSN rats adapt to mild energy restriction by reducing body fat, EE and PA mainly during the dark period while growth proceeds and lean body mass is preserved. At higher levels of energy restrictions there is decreased growth, body fat and lean mass. Moreover EE and PA are also reduced during both light and dark periods.

  10. Enhanced Engraftment of a Very Low-Dose Cord Blood Unit in an Adult Haemopoietic Transplant by Addition of Six Mismatched Viable Cord Units

    Directory of Open Access Journals (Sweden)

    Stephen J. Proctor

    2010-01-01

    , supported by six mismatched cord blood units (one unit per 10 kg recipient weight. No adverse reaction occurred following the infusion of mismatched units and engraftment of the suboptimal-dose matched unit occurred rapidly, with no molecular evidence of engraftment of mismatched cords. Early molecular remission of ALL was demonstrated using a novel PCR for a mitochondrial DNA mutation in the leukaemic clone. The cell dose of the matched cord was well below that recommended to engraft a 70 kg recipient. We suggest that a factor or factors in the mismatched cords enhanced/supported engraftment of the matched cord.

  11. Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial

    NARCIS (Netherlands)

    Hermanides, J.; Nørgaard, K.; Bruttomesso, D.; Mathieu, C.; Frid, A.; Dayan, C. M.; Diem, P.; Fermon, C.; Wentholt, I. M. E.; Hoekstra, J. B. L.; DeVries, J. H.

    2011-01-01

    To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes. In this investigator-initiated multi-centre trial (the Eurythmics Trial) in eight outpatient centres in Europe, we randomized 83 patients with

  12. High frequency of sub-optimal semen quality in an unselected population of young men

    DEFF Research Database (Denmark)

    Andersen, A G; Jensen, T K; Carlsen, E

    2000-01-01

    for military service, this provided a unique opportunity to study the reproductive function in an unbiased population. Altogether 891 young men delivered a blood sample in which reproductive hormones were measured. From 708 of these men data were also obtained on semen quality and testis size. The median sperm...... immotile spermatozoa and follicle stimulating hormone. Possible causes for this high frequency of young men with suboptimal semen quality are obscure and need to be explored. Whether these findings apply for young male populations of comparable countries remains to be seen....

  13. Comprehensive analysis of a medication dosing error related to CPOE.

    Science.gov (United States)

    Horsky, Jan; Kuperman, Gilad J; Patel, Vimla L

    2005-01-01

    This case study of a serious medication error demonstrates the necessity of a comprehensive methodology for the analysis of failures in interaction between humans and information systems. The authors used a novel approach to analyze a dosing error related to computer-based ordering of potassium chloride (KCl). The method included a chronological reconstruction of events and their interdependencies from provider order entry usage logs, semistructured interviews with involved clinicians, and interface usability inspection of the ordering system. Information collected from all sources was compared and evaluated to understand how the error evolved and propagated through the system. In this case, the error was the product of faults in interaction among human and system agents that methods limited in scope to their distinct analytical domains would not identify. The authors characterized errors in several converging aspects of the drug ordering process: confusing on-screen laboratory results review, system usability difficulties, user training problems, and suboptimal clinical system safeguards that all contributed to a serious dosing error. The results of the authors' analysis were used to formulate specific recommendations for interface layout and functionality modifications, suggest new user alerts, propose changes to user training, and address error-prone steps of the KCl ordering process to reduce the risk of future medication dosing errors.

  14. A randomized controlled trial of vitamin D dosing strategies after acute hip fracture: No advantage of loading doses over daily supplementation

    Directory of Open Access Journals (Sweden)

    Farrauto Leonardo

    2011-06-01

    Full Text Available Abstract Background There remains uncertainty regarding the appropriate therapeutic management of hip fracture patients. The primary aim of our study was to examine whether large loading doses in addition to daily vitamin D offered any advantage over a simple daily low-dose vitamin D regimen for increasing vitamin D levels. Methods In this randomized controlled study, patients over age 50 with an acute fragility hip fracture were enrolled from two hospital sites in Ontario, Canada. Participants were randomized to one of three loading dose groups: placebo; 50,000 IU vitamin D2; or 100,000 IU D2. Following a placebo/loading dose, all patients received a daily tablet of 1,000 IU vitamin D3 for 90 days. Serum 25-hydroxy vitamin D (25-OHD was measured at baseline, discharge from acute care (approximately 4-weeks, and 3-months. Results Sixty-five patients were enrolled in the study (44% male. An immediate rise in 25-OHD occurred in the 100,000 group, however there were no significant differences in 25-OHD between the placebo, 50,000 and 100,000 loading dose groups after 4-weeks (69.3, 84.5, 75.6 nmol/L, p = 0.15 and 3-months (86.7, 84.2, 73.3 nmol/L, p = 0.09, respectively. At the end of the study, approximately 75% of the placebo and 50,000 groups had reached the target therapeutic range (75 nmol/L, and 44% of the 100,000 group. Conclusions In correcting vitamin D insufficiency/deficiency in elderly patients with hip fracture, our findings suggest that starting with a lower daily dose of Vitamin D3 achieved similar results as providing an additional large loading dose of Vitamin D2. At the end of the study, all three groups were equally effective in attaining improvement in 25-OHD levels. Given that a daily dose of 1,000 IU vitamin D3 (with or without a loading dose resulted in at least 25% of patients having suboptimal vitamin D status, patients with acute hip fracture may benefit from a higher daily dose of vitamin D. Trial registration Clinical

  15. Optimal and Suboptimal Finger Selection Algorithms for MMSE Rake Receivers in Impulse Radio Ultra-Wideband Systems

    Directory of Open Access Journals (Sweden)

    Chiang Mung

    2006-01-01

    Full Text Available The problem of choosing the optimal multipath components to be employed at a minimum mean square error (MMSE selective Rake receiver is considered for an impulse radio ultra-wideband system. First, the optimal finger selection problem is formulated as an integer programming problem with a nonconvex objective function. Then, the objective function is approximated by a convex function and the integer programming problem is solved by means of constraint relaxation techniques. The proposed algorithms are suboptimal due to the approximate objective function and the constraint relaxation steps. However, they perform better than the conventional finger selection algorithm, which is suboptimal since it ignores the correlation between multipath components, and they can get quite close to the optimal scheme that cannot be implemented in practice due to its complexity. In addition to the convex relaxation techniques, a genetic-algorithm- (GA- based approach is proposed, which does not need any approximations or integer relaxations. This iterative algorithm is based on the direct evaluation of the objective function, and can achieve near-optimal performance with a reasonable number of iterations. Simulation results are presented to compare the performance of the proposed finger selection algorithms with that of the conventional and the optimal schemes.

  16. A Suboptimal Power-Saving Transmission Scheme in Multiple Component Carrier Networks

    Science.gov (United States)

    Chung, Yao-Liang; Tsai, Zsehong

    Power consumption due to transmissions in base stations (BSs) has been a major contributor to communication-related CO2 emissions. A power optimization model is developed in this study with respect to radio resource allocation and activation in a multiple Component Carrier (CC) environment. We formulate and solve the power-minimization problem of the BS transceivers for multiple-CC networks with carrier aggregation, while maintaining the overall system and respective users' utilities above minimum levels. The optimized power consumption based on this model can be viewed as a lower bound of that of other algorithms employed in practice. A suboptimal scheme with low computation complexity is proposed. Numerical results show that the power consumption of our scheme is much better than that of the conventional one in which all CCs are always active, if both schemes maintain the same required utilities.

  17. Efficacy of prokinetics with a split-dose of polyethylene glycol in bowel preparation for morning colonoscopy: a randomized controlled trial.

    Science.gov (United States)

    Kim, Hyoung Jun; Kim, Tae Oh; Shin, Bong Chul; Woo, Jae Gon; Seo, Eun Hee; Joo, Hee Rin; Heo, Nae-Yun; Park, Jongha; Park, Seung Ha; Yang, Sung Yeon; Moon, Young Soo; Shin, Jin-Yong; Lee, Nae Young

    2012-01-01

    Currently, a split-dose of polyethylene glycol (PEG) is the mainstay of bowel preparation due to its tolerability, bowel-cleansing action, and safety. However, bowel preparation with PEG is suboptimal because residual fluid reduces the polyp detection rate and requires a more thorough colon inspection. The aim of our study was to demonstrate the efficacy of a sufficient dose of prokinetics on bowel cleansing together with split-dose PEG. A prospective endoscopist-blinded study was conducted. Patients were randomly allocated to two groups: prokinetic with split-dose PEG or split-dose PEG alone. A prokinetic [100 mg itopride (Itomed)], was administered twice simultaneously with each split-dose of PEG. Bowel-cleansing efficacy was measured by endoscopists using the Ottawa scale and the segmental fluidity scale score. Each participant completed a bowel preparation survey. Mean scores from the Ottawa scale, segmental fluid scale, and rate of poor preparation were compared between both groups. Patients in the prokinetics with split-dose PEG group showed significantly lower total Ottawa and segmental fluid scores compared with patients in the split-dose of PEG alone group. A sufficient dose of prokinetics with a split-dose of PEG showed efficacy in bowel cleansing for morning colonoscopy, largely due to the reduction in colonic fluid. Copyright © 2012 S. Karger AG, Basel.

  18. High prevalence of suboptimal vitamin B12 status in young adult women of South Asian and European ethnicity.

    Science.gov (United States)

    Quay, Teo A W; Schroder, Theresa H; Jeruszka-Bielak, Marta; Li, Wangyang; Devlin, Angela M; Barr, Susan I; Lamers, Yvonne

    2015-12-01

    Suboptimal vitamin B12 (B12) status has been associated with an increased risk of congenital anomalies, preterm birth, and childhood insulin resistance. South Asians - Canada's largest minority group - and women of reproductive age are vulnerable to B12 deficiency. This study aimed to assess the prevalence of and factors associated with B12 deficiency and suboptimal B12 status in a convenience sample of young adult women of South Asian and European descent in Metro Vancouver. We measured serum B12, holotranscobalamin, plasma methylmalonic acid, red blood cell and plasma folate, and hematologic parameters in 206 nonpregnant, healthy women aged 19-35 years. Categorization for B12 status adhered to serum B12 cutoffs for deficiency (women is higher than in the general Canadian population. In light of maternal and fetal health risks associated with B12 inadequacy in early-pregnancy, practitioners should consider monitoring B12 status before and during early pregnancy, especially in immigrants and women with low dietary B12 intakes including non-users of vitamin supplements.

  19. Energy expenditures & physical activity in rats with chronic suboptimal nutrition.

    Science.gov (United States)

    Rising, Russell; Lifshitz, Fima

    2006-01-31

    Sub-optimally nourished rats show reduced growth, biochemical and physiological changes. However, no one has assessed metabolic rate adaptations in rats subjected to chronic suboptimal nutrition (CSN). In this study energy expenditure (EE; kcal/100 g body weight) and physical activity (PA; oscillations in weight/min/kg body weight) were assessed in rats subjected to three levels of CSN. Body weight gain was diminished (76.7 +/- 12.0 and 61.6 +/- 11.0 g) in rats fed 70 and 60% of the ad-libitum fed controls which gained more weight (148.5 +/- 32.3 g). The rats fed 80% gained weight similarly to controls (136.3 +/- 10.5 g). Percent Fat-free body mass was reduced (143.8 +/- 8.7 and 142.0 +/- 7.6 g) in rats fed 70 and 60% of ad-libitum, but not in those fed 80% (200.8 +/- 17.5 g) as compared with controls (201.6 +/- 33.4 g). Body fat (g) decreased in rats fed 80% (19.7 +/- 5.3), 70% (15.3 +/- 3.5) and 60% (9.6 +/- 2.7) of ad-libitum in comparison to controls (26.0 +/- 6.7). EE and PA were also altered by CSN. The control rats increased their EE and PA during the dark periods by 1.4 +/- 0.8 and 1.7 +/- 1.1 respectively, as compared with light the period; whereas CSN rats fed 80 and 70% of ad-libitum energy intake had reduced EE and PA during the dark periods as compared with the light period EE(7.5 +/- 1.4 and 7.8 +/- 0.6 vs. 9.0 +/- 1.2 and 9.7 +/- 0.8; p vs. 4.1 +/- 0.9 and 2.4 +/- 0.4; p vs. 0.95 +/- 0.03 and 0.91 +/- 0.05 p light (7.1 +/- 1.4) and dark period (6.2 +/- 1.0) EE and PA (3.4 +/- 0.9 and 2.5 +/- 0.5 respectively) were reduced in rats fed 60% of ad-libitum energy intake. CSN rats adapt to mild energy restriction by reducing body fat, EE and PA mainly during the dark period while growth proceeds and lean body mass is preserved. At higher levels of energy restrictions there is decreased growth, body fat and lean mass. Moreover EE and PA are also reduced during both light and dark periods.

  20. Design of a study on suboptimal cognitive acts in the diagnostic process, the effect on patient outcomes and the influence of workload, fatigue and experience of physician

    Directory of Open Access Journals (Sweden)

    van der Wal Gerrit

    2009-04-01

    Full Text Available Abstract Background Diagnostic error is an important error type since diagnostic adverse events are regularly judged as being preventable and the consequences are considered to be severe. Existing research often focuses on either diagnostic adverse events or on the errors in diagnostic reasoning. Whether and when an incorrect diagnostic process results in adverse outcomes has not been studied extensively. The present paper describes the design of a study that aims to study the relationship between a suboptimal diagnostic process and patient outcomes. In addition, the role of personal and circumstantial factors on the quality of the diagnostic process will be examined. Methods/Design The research questions were addressed using several data sources. First, the differential diagnosis was assessed concurrently to the diagnostic process. Second, the patient records of 248 patients suffering from shortness of breath were reviewed by expert internists in order to reveal suboptimal cognitive acts and (potential consequences for the patient. The suboptimal cognitive acts were discussed with the treating physicians and classified with the taxonomy of unsafe acts. Third, workload, fatigue and work experience were measured during the physicians work. Workload and fatigue were measured during the physicians shift using the NASA tlx questionnaire on a handheld computer. Physicians participating in the study also answered questions about their work experience. Discussion The design used in this study provides insight into the relationship between suboptimal cognitive acts in the diagnostic process and possible consequences for the patient. Suboptimal cognitive acts in the diagnostic process and its causes can be revealed. Additional measurements of workload, fatigue and experience allow examining the influence of these factors on the diagnostic process. In conclusion, the present design provides a method with which insights in weaknesses of the diagnostic

  1. Effect of stress induced by suboptimal growth factors on survival of Escherichia coli O157:H7.

    Science.gov (United States)

    Uyttendaele, M; Taverniers, I; Debevere, J

    2001-05-21

    This study investigated the growth and survival of E. coli O157:H7 exposed to a combination of suboptimal factors (22 degrees C, 7 degrees C, -18 degrees C/0.5% NaCl, 5.0% NaCl/pH 7.0, pH 5.4, pH 4.5/addition of lactic acid) in a simulation medium for red meat (beef gravy). Prolonged survival was noted as the imposed stress was more severe, and as multiple growth factors became suboptimal. At a defined temperature (7 degrees C or -18 degrees C), survival was prolonged at the more acid, more suboptimal pH (pH 4.5 > pH 5.4 > pH 7.0) while at a defined pH (pH 4.5), better survival was observed at 7 degrees C than at 22 degrees C. This suggests that application of the hurdle concept for preservation of food may inhibit outgrowth but induce prolonged survival of E. coli O157:H7 in minimal processed foods. At both 22 degrees C and 7 degrees C, the addition of lactic acid instead of HCl to reduce pH (to pH 4.5) resulted in a more rapid decrease of E. coli O157:H7. High survival was observed in beef gravy, pH 5.4 at -18 degrees C (simulation of frozen meat)-reduction of log 3.0 to log 1.9 after 43 days--and in beef gravy, pH 4.5 and 5% NaCl at 7 degrees C (simulation of a fermented dried meat product kept in refrigeration)--less than 1 log reduction in 43 days. In these circumstances, however, a high degree of sublethal damage of the bacterial cells was noted. The degree of sublethal damage can be estimated from the difference in recovery of the pathogen on the non-selective TSA medium and the selective SMAC medium.

  2. Effective dose calculations in conventional diagnostic X-ray examinations for adult and paediatric patients in a large Italian hospital

    International Nuclear Information System (INIS)

    Compagnone, G.; Pagan, L.; Bergamini, C.

    2005-01-01

    The effective dose E is an efficient and powerful parameter to study the radioprotection of the patient. In our hospital, eight radiological departments and more than 100 radiological X-ray tubes are present. The effective doses were calculated for adults and paediatric patients in 10 standard projections. To calculate E, first the entrance skin dose (ESD) was evaluated by a mathematical model that was validated by >400 direct measurements taken with an ionisation chamber on four different phantoms: the overall accuracy of the model was better than 12%. Second, to relate ESD to E, conversion coefficients calculated by Monte Carlo techniques were used. The E-values obtained were of the same order as those presented in the literature. Finally, we analysed how the study of E distributions among the various radiological departments can help to optimise the procedures, by identifying the most critical examinations or sub-optimal clinical protocols. (authors)

  3. Acceleration of intensity-modulated radiotherapy dose calculation by importance sampling of the calculation matrices

    International Nuclear Information System (INIS)

    Thieke, Christian; Nill, Simeon; Oelfke, Uwe; Bortfeld, Thomas

    2002-01-01

    In inverse planning for intensity-modulated radiotherapy, the dose calculation is a crucial element limiting both the maximum achievable plan quality and the speed of the optimization process. One way to integrate accurate dose calculation algorithms into inverse planning is to precalculate the dose contribution of each beam element to each voxel for unit fluence. These precalculated values are stored in a big dose calculation matrix. Then the dose calculation during the iterative optimization process consists merely of matrix look-up and multiplication with the actual fluence values. However, because the dose calculation matrix can become very large, this ansatz requires a lot of computer memory and is still very time consuming, making it not practical for clinical routine without further modifications. In this work we present a new method to significantly reduce the number of entries in the dose calculation matrix. The method utilizes the fact that a photon pencil beam has a rapid radial dose falloff, and has very small dose values for the most part. In this low-dose part of the pencil beam, the dose contribution to a voxel is only integrated into the dose calculation matrix with a certain probability. Normalization with the reciprocal of this probability preserves the total energy, even though many matrix elements are omitted. Three probability distributions were tested to find the most accurate one for a given memory size. The sampling method is compared with the use of a fully filled matrix and with the well-known method of just cutting off the pencil beam at a certain lateral distance. A clinical example of a head and neck case is presented. It turns out that a sampled dose calculation matrix with only 1/3 of the entries of the fully filled matrix does not sacrifice the quality of the resulting plans, whereby the cutoff method results in a suboptimal treatment plan

  4. Using Six Sigma to improve once daily gentamicin dosing and therapeutic drug monitoring performance.

    LENUS (Irish Health Repository)

    Egan, Sean

    2012-08-07

    BACKGROUND: Safe, effective therapy with the antimicrobial gentamicin requires good practice in dose selection and monitoring of serum levels. Suboptimal therapy occurs with breakdown in the process of drug dosing, serum blood sampling, laboratory processing and level interpretation. Unintentional underdosing may result. This improvement effort aimed to optimise this process in an academic teaching hospital using Six Sigma process improvement methodology. METHODS: A multidisciplinary project team was formed. Process measures considered critical to quality were defined, and baseline practice was examined through process mapping and audit. Root cause analysis informed improvement measures. These included a new dosing and monitoring schedule, and standardised assay sampling and drug administration timing which maximised local capabilities. Three iterations of the improvement cycle were conducted over a 24-month period. RESULTS: The attainment of serum level sampling in the required time window improved by 85% (p≤0.0001). A 66% improvement in accuracy of dosing was observed (p≤0.0001). Unnecessary dose omission while awaiting level results and inadvertent disruption to therapy due to dosing and monitoring process breakdown were eliminated. Average daily dose administered increased from 3.39 mg\\/kg to 4.78 mg\\/kg\\/day. CONCLUSIONS: Using Six Sigma methodology enhanced gentamicin usage process performance. Local process related factors may adversely affect adherence to practice guidelines for gentamicin, a drug which is complex to use. It is vital to adapt dosing guidance and monitoring requirements so that they are capable of being implemented in the clinical environment as a matter of routine. Improvement may be achieved through a structured localised approach with multidisciplinary stakeholder involvement.

  5. Lack of effect of a booster dose of influenza vaccine in hemodialysis patients.

    Science.gov (United States)

    Tanzi, Elisabetta; Amendola, Antonella; Pariani, Elena; Zappa, Alessandra; Colzani, Daniela; Logias, Franco; Perego, Angelo; Zanetti, Alessandro R

    2007-08-01

    To assess whether the administration of a booster dose of influenza vaccine may enhance immune response in hemodialysis patients, 58 subjects were given two doses of the 2003/2004 season influenza vaccine, 1 month apart. "European Agency for the Evaluation of Medicinal Products" (EMEA) criteria were fully met in terms of percentage of response and of mean-fold increase of hemagglutination inhibiting (HI) antibody titer, but not in terms of seroprotection rates (HI antibody titers > or =1:40). The second vaccine administration did not result in additional increase in seroprotection rate or in geometric mean titers. Protective immune response against the epidemic A/H3N2 Fujian-like strain, antigenically distant from that included in the vaccine (A/Panama/2007/99) was observed in 94.7% of vaccinees protected against the A/H3N2 vaccine strain 1 month after immunization. No adverse reactions were reported during follow-up. The study findings suggest that immune response to influenza vaccination may be suboptimal in hemodialysis patients and that the administration of an additional second dose of vaccine does not improve the humoral response.

  6. Suboptimal decision making by children with ADHD in the face of risk

    DEFF Research Database (Denmark)

    Sørensen, Lin; Sonuga-Barke, Edmund; Eichele, Heike

    2017-01-01

    Objective: Suboptimal decision making in the face of risk (DMR) in children with attention-deficit hyperactivity disorder (ADHD) may be mediated by deficits in a number of different neuropsychological processes. We investigated DMR in children with ADHD using the Cambridge Gambling Task (CGT......-matched group of typically developing children (n = 34) performed the CGT. Results: As predicted, children with ADHD were not more prone to making risky choices (i.e., risk proneness). However, they had difficulty adjusting to changing risk levels and were more delay aversive-with these 2 effects being...... correlated. Conclusions: Our findings add to the growing body of evidence that children with ADHD do not favor risk taking per se when performing gambling tasks, but rather may lack the cognitive skills or motivational style to appraise changing patterns of risk effectively....

  7. Robust Adaptive LCMV Beamformer Based On An Iterative Suboptimal Solution

    Directory of Open Access Journals (Sweden)

    Xiansheng Guo

    2015-06-01

    Full Text Available The main drawback of closed-form solution of linearly constrained minimum variance (CF-LCMV beamformer is the dilemma of acquiring long observation time for stable covariance matrix estimates and short observation time to track dynamic behavior of targets, leading to poor performance including low signal-noise-ratio (SNR, low jammer-to-noise ratios (JNRs and small number of snapshots. Additionally, CF-LCMV suffers from heavy computational burden which mainly comes from two matrix inverse operations for computing the optimal weight vector. In this paper, we derive a low-complexity Robust Adaptive LCMV beamformer based on an Iterative Suboptimal solution (RAIS-LCMV using conjugate gradient (CG optimization method. The merit of our proposed method is threefold. Firstly, RAIS-LCMV beamformer can reduce the complexity of CF-LCMV remarkably. Secondly, RAIS-LCMV beamformer can adjust output adaptively based on measurement and its convergence speed is comparable. Finally, RAIS-LCMV algorithm has robust performance against low SNR, JNRs, and small number of snapshots. Simulation results demonstrate the superiority of our proposed algorithms.

  8. Coadministration of Hedera helix L. Extract Enabled Mice to Overcome Insufficient Protection against Influenza A/PR/8 Virus Infection under Suboptimal Treatment with Oseltamivir.

    Science.gov (United States)

    Hong, Eun-Hye; Song, Jae-Hyoung; Shim, Aeri; Lee, Bo-Ra; Kwon, Bo-Eun; Song, Hyuk-Hwan; Kim, Yeon-Jeong; Chang, Sun-Young; Jeong, Hyeon Gun; Kim, Jong Geal; Seo, Sang-Uk; Kim, HyunPyo; Kwon, YongSoo; Ko, Hyun-Jeong

    2015-01-01

    Several anti-influenza drugs that reduce disease manifestation exist, and although these drugs provide clinical benefits in infected patients, their efficacy is limited by the emergence of drug-resistant influenza viruses. In the current study, we assessed the therapeutic strategy of enhancing the antiviral efficacy of an existing neuraminidase inhibitor, oseltamivir, by coadministering with the leaf extract from Hedera helix L, commonly known as ivy. Ivy extract has anti-inflammatory, antibacterial, antifungal, and antihelminthic properties. In the present study, we investigated its potential antiviral properties against influenza A/PR/8 (PR8) virus in a mouse model with suboptimal oseltamivir that mimics a poor clinical response to antiviral drug treatment. Suboptimal oseltamivir resulted in insufficient protection against PR8 infection. Oral administration of ivy extract with suboptimal oseltamivir increased the antiviral activity of oseltamivir. Ivy extract and its compounds, particularly hedrasaponin F, significantly reduced the cytopathic effect in PR8-infected A549 cells in the presence of oseltamivir. Compared with oseltamivir treatment alone, coadministration of the fraction of ivy extract that contained the highest proportion of hedrasaponin F with oseltamivir decreased pulmonary inflammation in PR8-infected mice. Inflammatory cytokines and chemokines, including tumor necrosis factor-alpha and chemokine (C-C motif) ligand 2, were reduced by treatment with oseltamivir and the fraction of ivy extract. Analysis of inflammatory cell infiltration in the bronchial alveolar of PR8-infected mice revealed that CD11b+Ly6G+ and CD11b+Ly6Cint cells were recruited after virus infection; coadministration of the ivy extract fraction with oseltamivir reduced infiltration of these inflammatory cells. In a model of suboptimal oseltamivir treatment, coadministration of ivy extract fraction that includes hedrasaponin F increased protection against PR8 infection that could be

  9. Coadministration of Hedera helix L. Extract Enabled Mice to Overcome Insufficient Protection against Influenza A/PR/8 Virus Infection under Suboptimal Treatment with Oseltamivir.

    Directory of Open Access Journals (Sweden)

    Eun-Hye Hong

    Full Text Available Several anti-influenza drugs that reduce disease manifestation exist, and although these drugs provide clinical benefits in infected patients, their efficacy is limited by the emergence of drug-resistant influenza viruses. In the current study, we assessed the therapeutic strategy of enhancing the antiviral efficacy of an existing neuraminidase inhibitor, oseltamivir, by coadministering with the leaf extract from Hedera helix L, commonly known as ivy. Ivy extract has anti-inflammatory, antibacterial, antifungal, and antihelminthic properties. In the present study, we investigated its potential antiviral properties against influenza A/PR/8 (PR8 virus in a mouse model with suboptimal oseltamivir that mimics a poor clinical response to antiviral drug treatment. Suboptimal oseltamivir resulted in insufficient protection against PR8 infection. Oral administration of ivy extract with suboptimal oseltamivir increased the antiviral activity of oseltamivir. Ivy extract and its compounds, particularly hedrasaponin F, significantly reduced the cytopathic effect in PR8-infected A549 cells in the presence of oseltamivir. Compared with oseltamivir treatment alone, coadministration of the fraction of ivy extract that contained the highest proportion of hedrasaponin F with oseltamivir decreased pulmonary inflammation in PR8-infected mice. Inflammatory cytokines and chemokines, including tumor necrosis factor-alpha and chemokine (C-C motif ligand 2, were reduced by treatment with oseltamivir and the fraction of ivy extract. Analysis of inflammatory cell infiltration in the bronchial alveolar of PR8-infected mice revealed that CD11b+Ly6G+ and CD11b+Ly6Cint cells were recruited after virus infection; coadministration of the ivy extract fraction with oseltamivir reduced infiltration of these inflammatory cells. In a model of suboptimal oseltamivir treatment, coadministration of ivy extract fraction that includes hedrasaponin F increased protection against PR8

  10. [Effects of different NO3--N/NH4+-N ratios on cucumber seedlings growth, nitrogen absorption and metabolism under suboptimal temperature and light intensity].

    Science.gov (United States)

    Zhang, Xiao Cui; Liu, Yu Mei; Bai, Long Qiang; He, Chao Xing; Yu, Xian Chang; Li, Yan Su

    2016-08-01

    Cucumber (cv. Zhongnong 26) was used as material, the effects of NO 3 - -N/NH 4 + -N ratios on growth and physiological characteristics of cucumber seedlings under suboptimal temperature and light intensity (18 ℃/10 ℃,180 ± 20 μmol·m -2 ·s -1 ) were studied. Total nitrogen in the nutrient solution was equal and three NO 3 - -N/NH 4 + -N ratios, 26:2, 21:7 and 14:14, were applied as treatments. The results showed that cucumber treated by NO 3 - -N/NH 4 + -N=21:7 had the longest total root length, the biggest root volume and root surface area, and the maximum number of root tips. H + -ATPase activity and relative expression of genes encoding nitrate transporter (NRT) and ammonium transporter (AMT) in cucumber roots were increased significantly by the treatment of NO 3 - -N/NH 4 + -N=21:7. In addition, nitrate reductase (NR), glutamine synthetase (GS) and glutamate synthase (GOGAT) in cucumber leaves under the treatment of NO 3 - -N/NH 4 + -N=21:7 were higher. As a result, the nitrogen content and biomass of cucumber were significantly increased. Compared with the plants under the treatment of NO 3 - -N/NH 4 + -N=26:2 or 14:14, cucumber seedlings under the treatment of NO 3 - -N/NH 4 + -N=21:7 had the highest biomass and total dry mass (DM) which were increased by 14.0% and 19.3% respectively under suboptimal temperature and light intensity. In conclusion, under suboptimal environmental conditions, NO 3 - -N/NH 4 + -N ratio could be adjusted to increase nitrogen absorption and metabolism of cucumber and alleviate the de-trimental effects caused by suboptimal conditions and promoted the cucumber growth.

  11. Challenges and Potential Solutions – Individualised Antibiotic Dosing at the Bedside for Critically Ill Patients: a structured review

    Science.gov (United States)

    Roberts, Jason A.; Aziz, Mohd Hafiz Abdul; Lipman, Jeffrey; Mouton, Johan W.; Vinks, Alexander A.; Felton, Timothy W.; Hope, William W.; Farkas, Andras; Neely, Michael N.; Schentag, Jerome J.; Drusano, George; Frey, Otto R.; Theuretzbacher, Ursula; Kuti, Joseph L.

    2014-01-01

    Summary Infections in critically ill patients are associated with persistently poor clinical outcomes. These patients have severely altered and variable antibiotic pharmacokinetics and are infected by less susceptible pathogens. Antibiotic dosing that does not account for these features is likely to result in sub-optimal outcomes. In this paper, we review the patient- and pathogen-related challenges that contribute to inadequate antibiotic dosing and discuss how a process for individualised antibiotic therapy, that increases the accuracy of dosing, can be implemented to further optimise care for the critically ill patient. The process for optimised antibiotic dosing firstly requires determination of the physiological derangements in the patient that can alter antibiotic concentrations including altered fluid status, microvascular failure, serum albumin concentrations as well as altered renal and hepatic function. Secondly, knowledge of the susceptibility of the infecting pathogen should be determined through liaison with the microbiology laboratory. The patient and pathogen challenges can then be solved by combining susceptibility data with measured antibiotic concentration data (where possible) into a clinical dosing software. Such software uses pharmacokinetic-pharmacodynamic (PK/PD) models from critically ill patients to accurately predict the dosing requirements for the individual patient with the aim of optimising antibiotic exposure and maximising effectiveness. PMID:24768475

  12. Daptomycin versus linezolid for the treatment of vancomycin-resistant enterococcal bacteraemia: implications of daptomycin dose.

    Science.gov (United States)

    Chuang, Y-C; Lin, H-Y; Chen, P-Y; Lin, C-Y; Wang, J-T; Chang, S-C

    2016-10-01

    Treatment options for vancomycin-resistant enterococci (VRE) bloodstream infection are limited. Studies comparing daptomycin or linezolid in treating VRE bloodstream infection have conflicting results and suggest daptomycin underdosing. The responses to different daptomycin doses have not been studied. We conducted a multicentre prospective cohort study to compare linezolid and daptomycin (≥6 mg/kg) for the treatment of VRE bloodstream infection. The primary outcome was 14-day mortality. We used multivariate logistic regression analysis for outcome analysis and a generalized additive model for dose-dependent response estimation. Two hundred twelve patients were included (daptomycin, n = 141; linezolid, n = 71). All-cause 14-day mortality was higher in the daptomycin group (36.9% vs. 21.1%; p 0.03). After adjusting for confounders in logistic regression, mortality was lower in the linezolid group (adjusted odds ratio (aOR), 0.45; 95% confidence interval (CI), 0.21-0.96; p 0.04). The generalized additive model showed that higher-dose daptomycin (≥9 mg/kg) was associated with better survival than lower-dose daptomycin (6-9 mg/kg). Logistic regression showed that linezolid (aOR, 0.36; 95% CI, 0.17-0.79; p 0.01) and higher-dose daptomycin (aOR, 0.26; 95% CI, 0.09-0.74; p 0.01) independently predicted lower mortality compared to lower-dose daptomycin. Linezolid was not superior to higher-dose daptomycin in terms of mortality (aOR, 1.40; 95% CI, 0.45-4.37; p 0.57). Higher-dose daptomycin had lower mortality than lower-dose daptomycin. Despite higher mortality for lower-dose daptomycin than linezolid, linezolid conferred no survival benefit compared to higher-dose daptomycin. Our findings suggest that the recommended daptomycin dose is suboptimal for treating VRE bacteraemia. Copyright © 2016. Published by Elsevier Ltd.

  13. Work-Recreation Balance, Health-Promoting Lifestyles and Suboptimal Health Status in Southern China: A Cross-Sectional Study

    OpenAIRE

    Wu, Shengwei; Xuan, Zhengzheng; Li, Fei; Xiao, Wei; Fu, Xiuqiong; Jiang, Pingping; Chen, Jieyu; Xiang, Lei; Liu, Yanyan; Nie, Xiaoli; Luo, Ren; Sun, Xiaomin; Kwan, Hiuyee; Zhao, Xiaoshan

    2016-01-01

    Suboptimal health status (SHS)—an intermediate state between health and illness—refers to functional somatic symptoms that are medically undiagnosed. Although SHS has become a great challenge for global public health, very little about its etiology and mechanisms are known. Work-recreation balance is a part of work−life balance, and is related to stress which greatly influences health status. We therefore carried out a cross-sectional investigation between 2012 and 2013 within a clustered sam...

  14. Fourteen-day high-dose esomeprazole, amoxicillin and metronidazole as third-line treatment for Helicobacter pylori infection.

    Science.gov (United States)

    Puig, Ignasi; González-Santiago, Jesús M; Molina-Infante, Javier; Barrio, Jesús; Herranz, Maria Teresa; Algaba, Alicia; Castro, Manuel; Gisbert, Javier P; Calvet, Xavier

    2017-09-01

    The efficacy of currently recommended third-line therapies for Helicobacter pylori is suboptimal, even that of culture-guided treatments. Resistance to multiple antibiotics is the major factor related to treatment failure. The aim of this study was to evaluate the effectiveness and safety of a 14-day therapy using high-dose of amoxicillin, metronidazole and esomeprazole. Multicenter open-label study as a register in routine clinical practice in patients with two previous failures of eradication therapy. A triple therapy with esomeprazole 40 mg b.d., amoxicillin 1 g t.d.s and metronidazole 500 mg t.d.s for 2 weeks was administered as a third-line therapy after a first treatment including clarithromycin and a second treatment including a quinolone. Helicobacter pylori status was determined by either histology or 13 C-UBT both before and after treatment. A total of 68 patients were included in this study. An interim analysis showed that only three out of eight patients who had received metronidazole in previous eradication regimens were cured (37%, 95% CI 8-75); as a result, after this interim analysis only metronidazole-naïve patients were included. The ITT eradication rate in metronidazole-naive patients was 64% (95% CI 51-76). Adverse events occurred in 58% of patients, all of them mild-to-moderate. Two patients (3%) did not complete >90% of the treatment because of side effects. No severe adverse events occurred. Cure rates of this 14-day schedule using high-dose esomeprazole, amoxicillin and metronidazole as a third-line eradication regimen were suboptimal, especially in patients who had received metronidazole in previous failed eradication regimens. © 2017 John Wiley & Sons Ltd.

  15. Differences in the association between sickness absence and long-term sub-optimal health by occupational position: a 14-year follow-up in the GAZEL cohort.

    Science.gov (United States)

    Ferrie, Jane E; Kivimäki, Mika; Westerlund, Hugo; Head, Jenny; Melchior, Maria; Singh-Manoux, Archana; Zins, Marie; Goldberg, Marcel; Alexanderson, Kristina; Vahtera, Jussi

    2011-10-01

    Although sickness absence is a strong predictor of health, whether this association varies by occupational position has rarely been examined. The aim of this study was to investigate overall and diagnosis-specific sickness absence as a predictor of future long-term sub-optimal health by occupational position. This was a prospective occupational cohort study of 15 320 employees (73% men) aged 37-51. Sickness absences (1990-1992), included in 13 diagnostic categories, were examined by occupational position in relation to self-rated health measured annually during 1993-2006. 60% of employees in higher occupational positions and 22% in lower positions had no sickness absence. Conversely, 9.5% of employees in higher positions and 40% in lower positions had over 30 sick-leave days. Repeated-measures logistic regression analyses adjusted for age, sex and chronic disease showed employees with over 30 days absence, compared to those with no absence, had approximately double the risk of sub-optimal health over the 14-year follow-up in all occupational positions. 1-30 days sick-leave was associated with greater odds of sub-optimal health in the high (OR 1.48; 95% CI 1.27 to 1.72) and intermediate (1.29; 1.15 to 1.45) but not lower occupational positions (1.06; 0.82 to 1.38). Differences by occupational position in the association between sickness absence in 13 specific diagnostic categories and sub-optimal health over the ensuing 14 years were limited to stronger associations observed with cancer and mental disorders in the higher occupational positions. The association between sickness absence of more than 30 days over 3 years and future long-term self-rated health appears to differ little by occupational position.

  16. The effect of plant-based diet and suboptimal environmental conditions on digestive function and diet-induced enteropathy in rainbow trout (Oncorhynchus mykiss)

    NARCIS (Netherlands)

    Mosberian-Tanha, P.; Schrama, J.W.; Landsverk, T.; Mydland, L.T.; Øverland, M.

    2018-01-01

    This experiment investigated intestinal enteropathy and digestive function of rainbow trout challenged with soybean meal-based diet (SBM) at optimal or suboptimal environments created by normal or reduced water flow, respectively. Oxygen level remained above 7 mg L-1 for optimal environment and

  17. Application of the tuning algorithm with the least squares approximation to the suboptimal control algorithm for integrating objects

    Science.gov (United States)

    Kuzishchin, V. F.; Merzlikina, E. I.; Van Va, Hoang

    2017-11-01

    The problem of PID and PI-algorithms tuning by means of the approximation by the least square method of the frequency response of a linear algorithm to the sub-optimal algorithm is considered. The advantage of the method is that the parameter values are obtained through one cycle of calculation. Recommendations how to choose the parameters of the least square method taking into consideration the plant dynamics are given. The parameters mentioned are the time constant of the filter, the approximation frequency range and the correction coefficient for the time delay parameter. The problem is considered for integrating plants for some practical cases (the level control system in a boiler drum). The transfer function of the suboptimal algorithm is determined relating to the disturbance that acts in the point of the control impact input, it is typical for thermal plants. In the recommendations it is taken into consideration that the overregulation for the transient process when the setpoint is changed is also limited. In order to compare the results the systems under consideration are also calculated by the classical method with the limited frequency oscillation index. The results given in the paper can be used by specialists dealing with tuning systems with the integrating plants.

  18. Missed doses of oral antihyperglycemic medications in US adults with type 2 diabetes mellitus: prevalence and self-reported reasons.

    Science.gov (United States)

    Vietri, Jeffrey T; Wlodarczyk, Catherine S; Lorenzo, Rose; Rajpathak, Swapnil

    2016-09-01

    Adherence to antihyperglycemic medication is thought to be suboptimal, but the proportion of patients missing doses, the number of doses missed, and reasons for missing are not well described. This survey was conducted to estimate the prevalence of and reasons for missed doses of oral antihyperglycemic medications among US adults with type 2 diabetes mellitus, and to explore associations between missed doses and health outcomes. The study was a cross-sectional patient survey. Respondents were contacted via a commercial survey panel and completed an on-line questionnaire via the Internet. Respondents provided information about their use of oral antihyperglycemic medications including doses missed in the prior 4 weeks, personal characteristics, and health outcomes. Weights were calculated to project the prevalence to the US adult population with type 2 diabetes mellitus. Outcomes were compared according to number of doses missed in the past 4 weeks using bivariate statistics and generalized linear models. Approximately 30% of adult patients with type 2 diabetes mellitus reported missing or reducing ≥1 dose of oral antihyperglycemic medication in the prior 4 weeks. Accidental missing was more commonly reported than purposeful skipping, with forgetting the most commonly reported reason. The timing of missed doses suggested respondents had also forgotten about doses missed, so the prevalence of missed doses is likely higher than reported. Outcomes were poorer among those who reported missing three or more doses in the prior 4 weeks. A substantial number of US adults with type 2 diabetes mellitus miss doses of their oral antihyperglycemic medications.

  19. [Associations between health-promoting lifestyle and suboptimal health status in Guangdong: a cross sectional study].

    Science.gov (United States)

    Chen, Jie-Yu; Yang, Le-Bin; Jiang, Ping-Ping; Sun, Xiao-Min; Yu, Ke-Qiang; Li, Fei; Wu, Sheng-Wei; Ji, Yan-Zhao; Zhao, Xiao-Shan; Luo, Ren

    2016-04-01

    To investigate associations between health-promoting lifestyle and suboptimal health status (SHS) in the population of Guangdong province. A cross-sectional survey was conducted in a clustered sample of 24 159 individuals aged 12-80 years from 2012 to 2013. Health-promoting lifestyle was assessed via the Health-Promoting Lifestyle Profile (HPLP-II), and SHS was evaluated using the medical examination report and Sub-health Measurement Scale V1.0 (SHMS V1.0). Of the 24159 participants, subjects with SHS (46.0%) and disease status (35.2%) accounted for a much higher percentage than healthy subjects (18.8%). Regression analyses revealed a significant association between health status and healthy lifestyle (PUnhealthy lifestyle was an important risk factor for SHS and disease, especially the former. Compared with the participants with a healthy lifestyle (minimal exposure), after demographic adjustment, subjects with a 'poor' lifestyle (maximal exposure) were at a 43 times higher risk of developing SHS (OR: 42.825, 95% CI: 30.567-59.997), those with a general lifestyle were at a 21 times higher risk of SHS (OR: 21.072, 95%CI: 17.258-25.729), and those with a suboptimal lifestyle had a 4 times higher risk (OR: 4.085, 95%CI: 3.352-4.979). In the general population, the major risk factors for SHS included poor stress management, poor self-actualization, inactive exercise and poor interpersonal relationship. s Unhealthy lifestyles are significantly related to an increased risk of SHS. Intervention of unhealthy lifestyles, controlling the risk factors of SHS, and rigorous management of the time window of SHS are necessary to promote the heath status.

  20. Adaptive suboptimal second-order sliding mode control for microgrids

    Science.gov (United States)

    Incremona, Gian Paolo; Cucuzzella, Michele; Ferrara, Antonella

    2016-09-01

    This paper deals with the design of adaptive suboptimal second-order sliding mode (ASSOSM) control laws for grid-connected microgrids. Due to the presence of the inverter, of unpredicted load changes, of switching among different renewable energy sources, and of electrical parameters variations, the microgrid model is usually affected by uncertain terms which are bounded, but with unknown upper bounds. To theoretically frame the control problem, the class of second-order systems in Brunovsky canonical form, characterised by the presence of matched uncertain terms with unknown bounds, is first considered. Four adaptive strategies are designed, analysed and compared to select the most effective ones to be applied to the microgrid case study. In the first two strategies, the control amplitude is continuously adjusted, so as to arrive at dominating the effect of the uncertainty on the controlled system. When a suitable control amplitude is attained, the origin of the state space of the auxiliary system becomes attractive. In the other two strategies, a suitable blend between two components, one mainly working during the reaching phase, the other being the predominant one in a vicinity of the sliding manifold, is generated, so as to reduce the control amplitude in steady state. The microgrid system in a grid-connected operation mode, controlled via the selected ASSOSM control strategies, exhibits appreciable stability properties, as proved theoretically and shown in simulation.

  1. Effects of feeding frequency on apparent energy and nutrient digestibility/availability of channel catfish, Ictalurus punctatus, reared at optimal and suboptimal temperatures

    Science.gov (United States)

    This study examined the effects of feeding frequency (daily versus every other day [EOD]) on nutrient digestibility/availability of channel catfish, Ictalurus punctatus, reared at optimal (30 C) and suboptimal (24 C) temperatures. A 28% protein practical diet was used as the test diet, and chromic o...

  2. Testing of the analytical anisotropic algorithm for photon dose calculation

    International Nuclear Information System (INIS)

    Esch, Ann van; Tillikainen, Laura; Pyykkonen, Jukka; Tenhunen, Mikko; Helminen, Hannu; Siljamaeki, Sami; Alakuijala, Jyrki; Paiusco, Marta; Iori, Mauro; Huyskens, Dominique P.

    2006-01-01

    The analytical anisotropic algorithm (AAA) was implemented in the Eclipse (Varian Medical Systems) treatment planning system to replace the single pencil beam (SPB) algorithm for the calculation of dose distributions for photon beams. AAA was developed to improve the dose calculation accuracy, especially in heterogeneous media. The total dose deposition is calculated as the superposition of the dose deposited by two photon sources (primary and secondary) and by an electron contamination source. The photon dose is calculated as a three-dimensional convolution of Monte-Carlo precalculated scatter kernels, scaled according to the electron density matrix. For the configuration of AAA, an optimization algorithm determines the parameters characterizing the multiple source model by optimizing the agreement between the calculated and measured depth dose curves and profiles for the basic beam data. We have combined the acceptance tests obtained in three different departments for 6, 15, and 18 MV photon beams. The accuracy of AAA was tested for different field sizes (symmetric and asymmetric) for open fields, wedged fields, and static and dynamic multileaf collimation fields. Depth dose behavior at different source-to-phantom distances was investigated. Measurements were performed on homogeneous, water equivalent phantoms, on simple phantoms containing cork inhomogeneities, and on the thorax of an anthropomorphic phantom. Comparisons were made among measurements, AAA, and SPB calculations. The optimization procedure for the configuration of the algorithm was successful in reproducing the basic beam data with an overall accuracy of 3%, 1 mm in the build-up region, and 1%, 1 mm elsewhere. Testing of the algorithm in more clinical setups showed comparable results for depth dose curves, profiles, and monitor units of symmetric open and wedged beams below d max . The electron contamination model was found to be suboptimal to model the dose around d max , especially for physical

  3. Suboptimal vitamin D status in a population-based study of Asian children: prevalence and relation to allergic diseases and atopy.

    Directory of Open Access Journals (Sweden)

    Tsung-Chieh Yao

    Full Text Available BACKGROUND: New evidence shows high prevalence of vitamin D deficiency in many countries and some studies suggest a possible link between vitamin D status and allergic diseases. The objectives of this study were to determine the prevalence of suboptimal vitamin D status in a population sample of Asian children and to investigate the relationship of vitamin D status with allergic diseases and atopy. METHODS: Children aged 5-18 years (N = 1315 in the Prediction of Allergies in Taiwanese CHildren (PATCH study were evaluated using questionnaires, anthropometric measurements, and serum levels of 25-hydroxyvitamin D [25(OHD] and total and specific immunoglobulin E (IgE. RESULTS: The mean concentration of serum 25(OHD was 20.4 ng/mL (SD: 7.1 ng/mL. Vitamin D deficiency (defined as serum 25(OHD0.05. CONCLUSIONS: Low serum 25(OHD levels are remarkably common in this population sample of Asian children, suggesting that millions of children living in Taiwan may have suboptimal levels of vitamin D, which should be a matter of public health concern. Our results provides epidemiological evidence against the association of vitamin D status with various allergic diseases and atopy in Asian children.

  4. Lack of supportive leadership behavior predicts suboptimal self-rated health independent of job strain after 10 years of follow-up: findings from the population-based MONICA/KORA study.

    Science.gov (United States)

    Schmidt, Burkhard; Herr, Raphael M; Jarczok, Marc N; Baumert, Jens; Lukaschek, Karoline; Emeny, Rebecca T; Ladwig, Karl-Heinz

    2018-04-23

    Emerging cross-sectional research has identified lack of supportive leadership behavior (SLB) as a risk factor for workforce health. However, prospective evidence is hitherto lacking. SLB denotes support in difficult situations, recognition and feedback on work tasks. This study aims to determine the effect of SLB on suboptimal self-rated health (SRH) after 10 years considering potential moderators such as ages, sex, occupation and job strain. The sample included 884 employed participants drawn from the population-based prospective MONICA/KORA Study. SLB, SRH, as well as job strain were assessed by questionnaire. Logistic regressions estimated odds ratios (ORs) and corresponding 95% confidence intervals (CIs) for the effect of SLB at baseline on suboptimal SRH at follow-up. Analyses were adjusted for age, gender, lifestyle (alcohol, smoking, physical activity), socioeconomic status as well as for SRH and job strain at baseline. Lack of SLB was associated with suboptimal SRH at baseline [OR 2.00, (95% CI 1.19-3.46)] and at follow-up [OR 2.33, (95% CI 1.40-3.89)]. Additional adjustment for job strain did not substantially alter this association [OR 2.06, (95% CI 1.20-3.52)]. However, interactions between SLB and job strain as well as gender became evident, indicating moderating influences on the association between SLB and SRH. Lack of supportive leadership was associated with suboptimal SRH at 10 years' follow-up in men, even if SRH at baseline and other risk factors were taken into account. This effect is likely to be moderated by job strain.

  5. Suboptimal adherence to doxycycline and treatment outcomes among men with non-gonococcal urethritis: a prospective cohort study.

    Science.gov (United States)

    Khosropour, Christine M; Manhart, Lisa E; Colombara, Danny V; Gillespie, Catherine W; Lowens, M Sylvan; Totten, Patricia A; Golden, Matthew R; Simoni, Jane

    2014-02-01

    Doxycycline, one of two recommended therapies for non-gonococcal urethritis (NGU), consists of a 7-day course of therapy (100 mg BID). Since suboptimal adherence may contribute to poor treatment outcomes, we examined the association between self-reported imperfect adherence to doxycycline and clinical and microbiologic failure among men with NGU. Men aged ≥16 years with NGU attending a Seattle, WA, sexually transmitted diseases clinic were enrolled in a double-blind, parallel-group superiority trial from January 2007 to July 2011. Men were randomised to active doxycycline/placebo azithromycin or placebo doxycycline/active azithromycin. Imperfect adherence was defined as missing ≥1 dose in 7 days. Urine was tested for Chlamydia trachomatis (CT), Mycoplasma genitalium (MG), and Ureaplasma urealyticum-biovar 2 (UU-2) using nucleic acid amplification tests. Clinical failure (symptoms and ≥5 PMNs/HPF or discharge) and microbiologic failure (positive tests for CT, MG, and/or UU-2) were determined after 3 weeks. 184 men with NGU were randomised to active doxycycline and provided data on adherence. Baseline prevalence of CT, MG and UU-2 was 26%, 13% and 27%, respectively. 28% of men reported imperfect adherence, and this was associated with microbiologic failure among men with CT (aRR=9.33; 95% CI 1.00 to 89.2) and UU-2 (aRR=3.08; 95% CI 1.31 to 7.26) but not MG. Imperfect adherence was not significantly associated with clinical failure overall or for any specific pathogens, but it was more common among imperfectly adherent men with CT (aRR=2.63; 0.93-7.41, p=0.07). Adherence may be important for microbiologic cure of select pathogens. Factors other than adherence should be considered for CT-negative men with persistent NGU.

  6. Platelet aggregation according to body mass index in patients undergoing coronary stenting: should clopidogrel loading-dose be weight adjusted?

    Science.gov (United States)

    Angiolillo, Dominick J; Fernández-Ortiz, Antonio; Bernardo, Esther; Barrera Ramírez, Carlos; Sabaté, Manel; Fernandez, Cristina; Hernández-Antolín, Rosana; Escaned, Javier; Alfonso, Fernando; Macaya, Carlos

    2004-04-01

    A 300 mg clopidogrel loading-dose (LD) is widely used as an adjunct antithrombotic treatment to reduce the risk of thrombotic events early after coronary stenting (CS). Antithrombotic drugs commonly used during percutaneous coronary interventions, such as heparin and platelet glycoprotein IIb/IIIa inhibitors, but not clopidogrel LD, are weight-adjusted, and few data are available on which is the most effective clopidogrel LD regimen. The aim of this study was to assess whether body mass index (BMI) influenced platelet response to clopidogrel LD in patients undergoing CS. Adenosine diphosphate (ADP)-induced platelet aggregation (PA) was assessed by light transmittance aggregometry in 48 patients on aspirin treatment undergoing CS receiving a 300 mg clopidogrel LD at intervention time. PA was assessed at baseline and up to 24 hours after intervention. Patients were divided into 2 groups according to BMI: overweight (BMI greater than or equal to 25 kg/m2; 29 patients) and normal weight (BMI<25 kg/m2; 19 patients). PA was significantly higher in overweight than in normal weight patients at baseline (60.1+/-18.6%; versus 47.6+/-13.5%; p=0.01), at 24 hours (42.3+/-18.4% versus 38.5+/-18.3%; p=0.02) and during the overall study time (p=0.025). Percentage of inhibition of PA 24 hours following clopidogrel LD was suboptimal (<40%) in 59% and 26% of overweight and normal weight patients, respectively (p=0.04). An elevated BMI was the only independent predictor of suboptimal platelet response. These data suggest that overweight patients may need a higher loading-dose of clopidogrel and/or an adjunct antithrombotic treatment to adequately inhibit platelet aggregation early after CS.

  7. Traditional Chinese medicine and new concepts of predictive, preventive and personalized medicine in diagnosis and treatment of suboptimal health.

    Science.gov (United States)

    Wang, Wei; Russell, Alyce; Yan, Yuxiang

    2014-02-13

    The premise of disease-related phenotypes is the definition of the counterpart normality in medical sciences. Contrary to clinical practices that can be carefully planned according to clinical needs, heterogeneity and uncontrollability is the essence of humans in carrying out health studies. Full characterization of consistent phenotypes that define the general population is the basis to individual difference normalization in personalized medicine. Self-claimed normal status may not represent health because asymptomatic subjects may carry chronic diseases at their early stage, such as cancer, diabetes mellitus and atherosclerosis. Currently, treatments for non-communicable chronic diseases (NCD) are implemented after disease onset, which is a very much delayed approach from the perspective of predictive, preventive and personalized medicine (PPPM). A NCD pandemic will develop and be accompanied by increased global economic burden for healthcare systems throughout both developed and developing countries. This paper examples the characterization of the suboptimal health status (SHS) which represents a new PPPM challenge in a population with ambiguous health complaints such as general weakness, unexplained medical syndrome (UMS), chronic fatigue syndrome (CFS), myalgic encephalomyelitis (ME), post-viral fatigue syndrome (PVFS) and chronic fatigue immune dysfunction syndrome (CFIDS). We applied clinical informatic approaches and developed a questionnaire-suboptimal health status questionnaire-25 (SHSQ-25) for measuring SHS. The validity and reliability of this approach were evaluated in a small pilot study and then in a cross-sectional study of 3,405 participants in China. We found a correlation between SHS and systolic blood pressure, diastolic blood pressure, plasma glucose, total cholesterol and high-density lipoprotein (HDL) cholesterol among men, and a correlation between SHS and systolic blood pressure, diastolic blood pressure, total cholesterol, triglycerides

  8. Suboptimal Weight Loss and Weight Regain after Gastric Bypass Surgery?Postoperative Status of Energy Intake, Eating Behavior, Physical Activity, and Psychometrics

    OpenAIRE

    Amundsen, Tina; Str?mmen, Magnus; Martins, Catia

    2016-01-01

    BACKGROUND: Suboptimal weight loss (SWL) and weight regain (WR) after gastric bypass surgery (GB) remains poorly understood. OBJECTIVES: This study aims to compare GB patients experiencing SWL or significant WR (SigWR) with successful controls, regarding postoperative food intake, eating behavior, physical activity (PA), and psychometrics. METHODS: Forty-nine patients with >1 year post-surgery were classified as either experiencing SWL (excess body weight loss, EWL,

  9. Inverse problems for ODEs using contraction maps and suboptimality of the 'collage method'

    Science.gov (United States)

    Kunze, H. E.; Hicken, J. E.; Vrscay, E. R.

    2004-06-01

    Broad classes of inverse problems in differential and integral equations can be cast in the following framework: the optimal approximation of a target x of a suitable metric space X by the fixed point \\bar x of a contraction map T on X. The 'collage method' attempts to solve such inverse problems by finding an operator Tc that maps the target x as close as possible to itself. In the case of ODEs, the appropriate contraction maps are integral Picard operators. In practice, the target solutions possibly arise from an interpolation of experimental data points. In this paper, we investigate the suboptimality of the collage method. A simple inequality that provides upper bounds on the improvement over collage coding is presented and some examples are studied. We conclude that, at worst, the collage method provides an excellent starting point for further optimization, in contrast to more traditional searching methods that must first select a good starting point.

  10. Patterns of marijuana and tobacco use associated with suboptimal self-rated health among US adult ever users of marijuana

    OpenAIRE

    Tsai, James; Rolle, Italia V.; Singh, Tushar; Boulet, Sheree L.; McAfee, Timothy A.; Grant, Althea M.

    2017-01-01

    The purpose of this study was to examine the patterns of marijuana and tobacco use and their associations with suboptimal self-rated health (SRH) among US adults who reported ?ever, even once, using marijuana or hashish.? Data came from the 2009?2012 National Health and Nutrition Examination Survey, restricting to respondents aged 20 years and older who reported using marijuana at least once in their lifetime (n?=?3,210). We assessed the age-adjusted prevalence of mutually exclusive groups of...

  11. Pilot study on the additive effects of berberine and oral type 2 diabetes agents for patients with suboptimal glycemic control

    OpenAIRE

    Di Pierro, Francesco; Villanova,Nicola; Agostini,Federica; Soverini,Valentina; Marchesini,Giulio; Marzocchi,Rebecca

    2012-01-01

    Francesco Di Pierro,1 Nicola Villanova,2 Federica Agostini,2 Rebecca Marzocchi,2 Valentina Soverini,2 Giulio Marchesini21Scientific Department, Velleja Research, Milano, 2Diseases of Metabolism, S Orsola Malpighi Hospital, Bologna, ItalyBackground: Suboptimal glycemic control is a common situation in diabetes, regardless of the wide range of drugs available to reach glycemic targets. Basic research in diabetes is endeavoring to identify new actives working as insulin savers, use of which coul...

  12. Smartphone apps for calculating insulin dose: a systematic assessment.

    Science.gov (United States)

    Huckvale, Kit; Adomaviciute, Samanta; Prieto, José Tomás; Leow, Melvin Khee-Shing; Car, Josip

    2015-05-06

    subtle harms resulting from suboptimal glucose control. Healthcare professionals should exercise substantial caution in recommending unregulated dose calculators to patients and address app safety as part of self-management education. The prevalence of errors attributable to incorrect interpretation of medical principles underlines the importance of clinical input during app design. Systemic issues affecting the safety and suitability of higher-risk apps may require coordinated surveillance and action at national and international levels involving regulators, health agencies and app stores.

  13. Sub-optimal adherence to doxycycline and treatment outcomes among men with non-gonococcal urethritis: a prospective cohort study

    Science.gov (United States)

    Khosropour, Christine M.; Manhart, Lisa E.; Colombara, Danny V.; Gillespie, Catherine W.; Lowens, M. Sylvan; Totten, Patricia A.; Golden, Matthew R.; Simoni, Jane

    2014-01-01

    Objective Doxycycline, one of two recommended therapies for non-gonococcal urethritis (NGU), consists of a seven-day course of therapy (100mg BID). Since suboptimal adherence may contribute to poor treatment outcomes, we examined the association between self-reported imperfect adherence to doxycycline and clinical and microbiologic failure among men with NGU. Methods Men aged ≥16 years with NGU attending a Seattle, WA sexually transmitted diseases clinic were enrolled in a double-blind, parallel-group superiority trial from January 2007 to July 2011. Men were randomized to active doxycycline/placebo azithromycin or placebo doxycycline/active azithromycin. Imperfect adherence was defined as missing ≥1 dose in 7 days. Urine was tested for Chlamydia trachomatis (CT), Mycoplasma genitalium (MG), and Ureaplasma urealyticum-biovar2 (UU-2) using nucleic acid amplification tests. Clinical failure (symptoms and ≥5 PMNs/HPF or discharge) and microbiologic failure (positive tests for CT, MG, and/or UU-2) were determined after 3-weeks. Results 184 men with NGU were randomized to active doxycycline and provided data on adherence. Baseline prevalence of CT, MG, and UU-2 was 26%, 13%, and 27%, respectively. 28% of men reported imperfect adherence and this was associated with microbiologic failure among men with CT (aRR=9.33; 95% CI=1.00–89.2) and UU-2 (aRR=3.08; 95% CI=1.31–7.26) but not MG. Imperfect adherence was not significantly associated with clinical failure overall or for any specific pathogens, but it was more common among imperfectly adherent men with CT (aRR=2.63; 0.93–7.41, p=0.07). Conclusions Adherence may be important for microbiologic cure of select pathogens. Factors other than adherence should be considered for CT-negative men with persistent NGU. PMID:24106340

  14. The Effect of Testosterone Topical Solution in Hypogonadal Men With Suboptimal Response to a Topical Testosterone Gel.

    Science.gov (United States)

    Burns, Patrick R; Kim, Edward D; Ruff, Dustin D; Seftel, Allen D

    2018-05-01

    This study evaluated the effect of axillary administration of a 2% testosterone solution (Axiron ® ) in hypogonadal (HGN) men who had had a suboptimal response to treatment with a commercially available topical testosterone gel. HGN men averaging 57 years old, with a mean body mass index of 31.9 kg/m 2 and median baseline testosterone level (T-level) of 185.2 ng/dL, who had failed to reach normal T-levels with a topical testosterone gel (Androgel 1.62%, Androgel, Testim, or Fortesta) were treated with a 2% testosterone solution until T-levels reached a normal range (from ≥300 to ≤1,050 ng/dL) or for up to 9 weeks. Outcomes included the cumulative percentage of men with a serum T-level in the normal range during treatment with Axiron and improvement in symptoms of low energy level and low sexual drive. During the study, 95% of HGN men (72/78) attained a T-level in the normal range. The median T-level at endpoint was 495.7 ng/dL, a threefold increase over baseline, p levels within the first 2 weeks of treatment. In a post hoc analysis, all subjects with baseline body mass indexes >35 kg/m 2 ( n = 19) achieved T-levels in the normal range. Prior to treatment, over 61% of subjects (48/78) reported impairment in either energy level or sexual drive. After treatment (or testosterone normalization), energy level improved in 75% of subjects and sexual drive improved in 70%. Topical 2% testosterone solution is a safe and effective treatment for HGN men who have had a suboptimal response to previous treatment with topical testosterone gels.

  15. Application of PK/PD Modeling in Veterinary Field: Dose Optimization and Drug Resistance Prediction

    Directory of Open Access Journals (Sweden)

    Ijaz Ahmad

    2016-01-01

    Full Text Available Among veterinary drugs, antibiotics are frequently used. The true mean of antibiotic treatment is to administer dose of drug that will have enough high possibility of attaining the preferred curative effect, with adequately low chance of concentration associated toxicity. Rising of antibacterial resistance and lack of novel antibiotic is a global crisis; therefore there is an urgent need to overcome this problem. Inappropriate antibiotic selection, group treatment, and suboptimal dosing are mostly responsible for the mentioned problem. One approach to minimizing the antibacterial resistance is to optimize the dosage regimen. PK/PD model is important realm to be used for that purpose from several years. PK/PD model describes the relationship between drug potency, microorganism exposed to drug, and the effect observed. Proper use of the most modern PK/PD modeling approaches in veterinary medicine can optimize the dosage for patient, which in turn reduce toxicity and reduce the emergence of resistance. The aim of this review is to look at the existing state and application of PK/PD in veterinary medicine based on in vitro, in vivo, healthy, and disease model.

  16. Suboptimal Regulation of a Class of Bilinear Interconnected Systems with Finite-Time Sliding Planning Horizons

    Directory of Open Access Journals (Sweden)

    M. de la Sen

    2008-01-01

    Full Text Available This paper focuses on the suboptimization of a class of multivariable discrete-time bilinear systems consisting of interconnected bilinear subsystems with respect to a linear quadratic optimal regulation criterion which involves the use of state weighting terms only. Conditions which ensure the controllability of the overall system are given as a previous requirement for optimization. Three transformations of variables are made on the system equations in order to implement the scheme on an equivalent linear system. This leads to an equivalent representation of the used quadratic performance index that involves the appearance of quadratic weighting terms related to both transformed input and state variables. In this way, a Riccati-matrix sequence, allowing the synthesis of a standard feedback control law, is obtained. Finally, the proposed control scheme is tested on realistic examples.

  17. [Phenylephrine dosing error in Intensive Care Unit. Case of the trimester].

    Science.gov (United States)

    2013-01-01

    A real clinical case reported to SENSAR is presented. A patient admitted to the surgical intensive care unit following a lung resection, suffered arterial hypotension. The nurse was asked to give the patient 1 mL of phenylephrine. A few seconds afterwards, the patient experienced a hypertensive crisis, which resolved spontaneously without damage. Thereafter, the nurse was interviewed and a dosing error was identified: she had mistakenly given the patient 1 mg of phenylephrine (1 mL) instead of 100 mcg (1 mL of the standard dilution, 1mg in 10 mL). The incident analysis revealed latent factors (event triggers) due to the lack of protocols and standard operating procedures, communication errors among team members (physician-nurse), suboptimal training, and underdeveloped safety culture. In order to preempt similar incidents in the future, the following actions were implemented in the surgical intensive care unit: a protocol for bolus and short lived infusions (del Dolor. Published by Elsevier España. All rights reserved.

  18. Doses to head and neck normal tissues for early stage Hodgkin lymphoma after involved node radiotherapy

    International Nuclear Information System (INIS)

    Maraldo, M.V.; Brodin, N.P.; Aznar, M.C.; Vogelius, I.R.; Munck af Rosenschöld, P.; Petersen, P.M.; Specht, L.

    2014-01-01

    Purpose: To evaluate dose plans for head and neck organs at risk (OARs) for classical Hodgkin lymphoma (HL) patients using involved node radiotherapy (INRT) delivered as 3D conformal radiotherapy (3DCRT), volumetric modulated arc therapy (VMAT), and intensity modulated proton therapy (PT), in comparison to the past mantle field (MF). Materials and methods: Data from 37 patients with cervical lymph node involvement were used. All patients originally received chemotherapy followed by 3DCRT–INRT (30.6 Gy). A VMAT–INRT, PT–INRT (both 30.6 Gy), and a MF plan (36 Gy) were simulated. Doses to head and neck OARs were compared with cumulative DVHs and repeated measures ANOVA. Results: The estimated median mean doses were 15.3, 19.3, 15.4, and 37.3 Gy (thyroid), 10.9, 12.0, 7.9, and 34.5 Gy (neck muscles), 2.3, 11.1, 1.8, and 37.1 Gy (larynx), 1.7, 5.1, 1.3, and 23.8 Gy (pharynx), 0.5, 0.8, 0.01, and 32.3 Gy (ipsilateral parotid), and 2.4, 3.8, 0.7, and 34.7 Gy (ipsilateral submandibular) with 3DCRT, VMAT, PT, and MF (all p < 0.0001), respectively. Conclusion: The use of INRT significantly lowered the estimated radiation dose to the head and neck OARs. VMAT appeared suboptimal compared to 3DCRT and PT, and for some patients, PT offered an additional gain

  19. A Suboptimal PTS Algorithm Based on Particle Swarm Optimization Technique for PAPR Reduction in OFDM Systems

    Directory of Open Access Journals (Sweden)

    Ho-Lung Hung

    2008-08-01

    Full Text Available A suboptimal partial transmit sequence (PTS based on particle swarm optimization (PSO algorithm is presented for the low computation complexity and the reduction of the peak-to-average power ratio (PAPR of an orthogonal frequency division multiplexing (OFDM system. In general, PTS technique can improve the PAPR statistics of an OFDM system. However, it will come with an exhaustive search over all combinations of allowed phase weighting factors and the search complexity increasing exponentially with the number of subblocks. In this paper, we work around potentially computational intractability; the proposed PSO scheme exploits heuristics to search the optimal combination of phase factors with low complexity. Simulation results show that the new technique can effectively reduce the computation complexity and PAPR reduction.

  20. A Suboptimal PTS Algorithm Based on Particle Swarm Optimization Technique for PAPR Reduction in OFDM Systems

    Directory of Open Access Journals (Sweden)

    Lee Shu-Hong

    2008-01-01

    Full Text Available Abstract A suboptimal partial transmit sequence (PTS based on particle swarm optimization (PSO algorithm is presented for the low computation complexity and the reduction of the peak-to-average power ratio (PAPR of an orthogonal frequency division multiplexing (OFDM system. In general, PTS technique can improve the PAPR statistics of an OFDM system. However, it will come with an exhaustive search over all combinations of allowed phase weighting factors and the search complexity increasing exponentially with the number of subblocks. In this paper, we work around potentially computational intractability; the proposed PSO scheme exploits heuristics to search the optimal combination of phase factors with low complexity. Simulation results show that the new technique can effectively reduce the computation complexity and PAPR reduction.

  1. AMT1;1 transgenic rice plants with enhanced NH4(+) permeability show superior growth and higher yield under optimal and suboptimal NH4(+) conditions.

    Science.gov (United States)

    Ranathunge, Kosala; El-Kereamy, Ashraf; Gidda, Satinder; Bi, Yong-Mei; Rothstein, Steven J

    2014-03-01

    The major source of nitrogen for rice (Oryza sativa L.) is ammonium (NH4(+)). The NH4(+) uptake of roots is mainly governed by membrane transporters, with OsAMT1;1 being a prominent member of the OsAMT1 gene family that is known to be involved in NH4(+) transport in rice plants. However, little is known about its involvement in NH4(+) uptake in rice roots and subsequent effects on NH4(+) assimilation. This study shows that OsAMT1;1 is a constitutively expressed, nitrogen-responsive gene, and its protein product is localized in the plasma membrane. Its expression level is under the control of circadian rhythm. Transgenic rice lines (L-2 and L-3) overexpressing the OsAMT1;1 gene had the same root structure as the wild type (WT). However, they had 2-fold greater NH4(+) permeability than the WT, whereas OsAMT1;1 gene expression was 20-fold higher than in the WT. Analogous to the expression, transgenic lines had a higher NH4(+) content in the shoots and roots than the WT. Direct NH4(+) fluxes in the xylem showed that the transgenic lines had significantly greater uptake rates than the WT. Higher NH4(+) contents also promoted higher expression levels of genes in the nitrogen assimilation pathway, resulting in greater nitrogen assimilates, chlorophyll, starch, sugars, and grain yield in transgenic lines than in the WT under suboptimal and optimal nitrogen conditions. OsAMT1;1 also enhanced overall plant growth, especially under suboptimal NH4(+) levels. These results suggest that OsAMT1;1 has the potential for improving nitrogen use efficiency, plant growth, and grain yield under both suboptimal and optimal nitrogen fertilizer conditions.

  2. AMT1;1 transgenic rice plants with enhanced NH4 + permeability show superior growth and higher yield under optimal and suboptimal NH4 + conditions

    Science.gov (United States)

    Rothstein, Steven J.

    2014-01-01

    The major source of nitrogen for rice (Oryza sativa L.) is ammonium (NH4 +). The NH4 + uptake of roots is mainly governed by membrane transporters, with OsAMT1;1 being a prominent member of the OsAMT1 gene family that is known to be involved in NH4 + transport in rice plants. However, little is known about its involvement in NH4 + uptake in rice roots and subsequent effects on NH4 + assimilation. This study shows that OsAMT1;1 is a constitutively expressed, nitrogen-responsive gene, and its protein product is localized in the plasma membrane. Its expression level is under the control of circadian rhythm. Transgenic rice lines (L-2 and L-3) overexpressing the OsAMT1;1 gene had the same root structure as the wild type (WT). However, they had 2-fold greater NH4 + permeability than the WT, whereas OsAMT1;1 gene expression was 20-fold higher than in the WT. Analogous to the expression, transgenic lines had a higher NH4 + content in the shoots and roots than the WT. Direct NH4 + fluxes in the xylem showed that the transgenic lines had significantly greater uptake rates than the WT. Higher NH4 + contents also promoted higher expression levels of genes in the nitrogen assimilation pathway, resulting in greater nitrogen assimilates, chlorophyll, starch, sugars, and grain yield in transgenic lines than in the WT under suboptimal and optimal nitrogen conditions. OsAMT1;1 also enhanced overall plant growth, especially under suboptimal NH4 + levels. These results suggest that OsAMT1;1 has the potential for improving nitrogen use efficiency, plant growth, and grain yield under both suboptimal and optimal nitrogen fertilizer conditions. PMID:24420570

  3. The ciprofloxacin target AUC : MIC ratio is not reached in hospitalized patients with the recommended dosing regimens.

    Science.gov (United States)

    Haeseker, Michiel; Stolk, Leo; Nieman, Fred; Hoebe, Christian; Neef, Cees; Bruggeman, Cathrien; Verbon, Annelies

    2013-01-01

    The aim of this study was to determine the ciprofloxacin serum concentrations in hospitalized patients and to determine which percentage reached the efficacy target of AUC : MIC > 125. Additionally, the influence of demographic anthropomorphic and clinical parameters on the pharmacokinetics and pharmacodynamics of ciprofloxacin were investigated. In serum of 80 hospitalized patients ciprofloxacin concentrations were measured with reverse phase high performance liquid chromatography with fluorescence detection. The ciprofloxacin dose was 400-1200 mg day(-1) i.v. in two or three doses depending on renal function and causative bacteria. Pharmacokinetic parameters were calculated with maximum a posteriori Bayesian estimation (MW\\PHARM 3.60). A two compartment open model was used. Mean (± SD) age was 66 (± 17) years, the mean clearance corrected for bodyweight was 0.24 l h(-1) kg(-1) and the mean AUC was 49 mg l(-1) h. Ciprofloxacin clearance and thus AUC were associated with both age and serum creatinine. Of all patients, 21% and 75% of the patients, did not reach the proposed ciprofloxacin AUC : MIC > 125 target with MICs of 0.25 and 0.5 mg l(-1), respectively. A computer simulated increase in the daily dose from 800 mg to 1200 mg, decreased these percentages to 1% and 37%, respectively. A substantial proportion of the hospitalized patients did not reach the target ciprofloxacin AUC : MIC and are suboptimally dosed with recommended doses. Taking into account the increasing resistance to ciprofloxacin worldwide, a ciprofloxacin dose of 1200 mg i.v. daily in patients with normal renal function is necessary to reach the targeted AUC : MIC > 125. © 2012 The Authors. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  4. Model-Based Evaluation of Higher Doses of Rifampin Using a Semimechanistic Model Incorporating Autoinduction and Saturation of Hepatic Extraction.

    Science.gov (United States)

    Chirehwa, Maxwell T; Rustomjee, Roxana; Mthiyane, Thuli; Onyebujoh, Philip; Smith, Peter; McIlleron, Helen; Denti, Paolo

    2016-01-01

    Rifampin is a key sterilizing drug in the treatment of tuberculosis (TB). It induces its own metabolism, but neither the onset nor the extent of autoinduction has been adequately described. Currently, the World Health Organization recommends a rifampin dose of 8 to 12 mg/kg of body weight, which is believed to be suboptimal, and higher doses may potentially improve treatment outcomes. However, a nonlinear increase in exposure may be observed because of saturation of hepatic extraction and hence this should be taken into consideration when a dose increase is implemented. Intensive pharmacokinetic (PK) data from 61 HIV-TB-coinfected patients in South Africa were collected at four visits, on days 1, 8, 15, and 29, after initiation of treatment. Data were analyzed by population nonlinear mixed-effects modeling. Rifampin PKs were best described by using a transit compartment absorption and a well-stirred liver model with saturation of hepatic extraction, including a first-pass effect. Autoinduction was characterized by using an exponential-maturation model: hepatic clearance almost doubled from the baseline to steady state, with a half-life of around 4.5 days. The model predicts that increases in the dose of rifampin result in more-than-linear drug exposure increases as measured by the 24-h area under the concentration-time curve. Simulations with doses of up to 35 mg/kg produced results closely in line with those of clinical trials. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  5. Effects of Suboptimally Presented Erotic Pictures on Moral Judgments: A Cross-Cultural Comparison.

    Directory of Open Access Journals (Sweden)

    Antonio Olivera-La Rosa

    Full Text Available Previous research has identified a set of core factors that influence moral judgments. The present study addresses the interplay between moral judgments and four factors: (a incidental affects, (b sociocultural context, (c type of dilemma, and (d participant's sex. We asked participants in two different countries (Colombia and Spain to judge the acceptability of actions in response to personal and impersonal moral dilemmas. Before each dilemma an affective prime (erotic, pleasant or neutral pictures was presented suboptimally. Our results show that: a relative to neutral priming, erotic primes increase the acceptance of harm for a greater good (i.e., more utilitarian judgments, b relative to Colombians, Spanish participants rated causing harm as less acceptable, c relative to impersonal dilemmas, personal dilemmas reduced the acceptance of harm, and d relative to men, women were less likely to consider harm acceptable. Our results are congruent with findings showing that sex is a crucial factor in moral cognition, and they extend previous research by showing the interaction between culture and incidental factors in the making of moral judgments.

  6. Effects of Suboptimally Presented Erotic Pictures on Moral Judgments: A Cross-Cultural Comparison.

    Science.gov (United States)

    Olivera-La Rosa, Antonio; Corradi, Guido; Villacampa, Javier; Martí-Vilar, Manuel; Arango, Olber Eduardo; Rosselló, Jaume

    2016-01-01

    Previous research has identified a set of core factors that influence moral judgments. The present study addresses the interplay between moral judgments and four factors: (a) incidental affects, (b) sociocultural context, (c) type of dilemma, and (d) participant's sex. We asked participants in two different countries (Colombia and Spain) to judge the acceptability of actions in response to personal and impersonal moral dilemmas. Before each dilemma an affective prime (erotic, pleasant or neutral pictures) was presented suboptimally. Our results show that: a) relative to neutral priming, erotic primes increase the acceptance of harm for a greater good (i.e., more utilitarian judgments), b) relative to Colombians, Spanish participants rated causing harm as less acceptable, c) relative to impersonal dilemmas, personal dilemmas reduced the acceptance of harm, and d) relative to men, women were less likely to consider harm acceptable. Our results are congruent with findings showing that sex is a crucial factor in moral cognition, and they extend previous research by showing the interaction between culture and incidental factors in the making of moral judgments.

  7. The paradoxical effect of low reward probabilities in suboptimal choice.

    Science.gov (United States)

    Fortes, Inês; Pinto, Carlos; Machado, Armando; Vasconcelos, Marco

    2018-04-01

    When offered a choice between 2 alternatives, animals sometimes prefer the option yielding less food. For instance, pigeons and starlings prefer an option that on 20% of the trials presents a stimulus always followed by food, and on the remaining 80% of the trials presents a stimulus never followed by food (the Informative Option), over an option that provides food on 50% of the trials regardless of the stimulus presented (the Noninformative Option). To explain this suboptimal behavior, it has been hypothesized that animals ignore (or do not engage with) the stimulus that is never followed by food in the Informative Option. To assess when pigeons attend to the stimulus usually not followed by food, we increased the probability of reinforcement, p, in the presence of that stimulus. Across 2 experiments, we found that the value of the Informative Option decreased with p. To account for the results, we added to the Reinforcement Rate Model (and also to the Hyperbolic Discounting Model) an engagement function, f(p), that specified the likelihood the animal attends to a stimulus followed by reward with probability p, and then derived the model predictions for 2 forms of f(p), a linear function, and an all-or-none threshold function. Both models predicted the observed findings with a linear engagement function: The higher the probability of reinforcement after a stimulus, the higher the probability of engaging the stimulus, and, surprisingly, the less the value of the option comprising the stimulus. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  8. Fecal bulk, energy intake, and serum cholesterol: regression response of serum cholesterol to apparent digestibility of dry matter and suboptimal energy intake in rats on fiber-fat diet.

    Science.gov (United States)

    Normani, M Z; Hussain, S S; Lim, J K; Albrink, M J; Gunnells, C K; Davis, G K

    1981-10-01

    Two experiments were conducted in the rat to determine the relationships of serum cholesterol (SC, mg/dl), apparent digestibility of dry matter (DDM, %), and digested energy intake (DE, kcal/day) at suboptimal level of energy. The energies in diet and feces were determined by calorimetry. DE as percentage of the National Research Council requirement (DE%) was suboptimal (70 to 85%). The experiments had four to five isofibrous diets, and no fiber diets, supplemented with 0.2% crystalline cholesterol (CChol). Animals in experiment 1 were fed varying amounts of feed with 18% coconut oil in the diets where as these in experiment 2 were given fixed amounts of feed with either 6 or 18% oil. The following regressions (p less than 0.001) for SC were found: experiment 1: -1157.7 -5.97 DDM +105.5 CCI -1.48 CCI2 (r2 0.35), where CCI = CChol, mg/day; -1888.4 -2.66 DE +120.97 CCI -1.62 CCI2 (r2 0.37). Experiment 2: 762.99 -6.15 DDM -0.8 fat cal % -0.87DE% (r2 0.31), where fat cal % = fat calories % of DE. Data indicate that at suboptimal energy intake, SC was inversely related to (1) DDM, (2) fat cal, and (3) total energy intake. Liver cholesterol lowering effect of the dietary fiber was also observed. The above findings help to elucidate various conflicting reports related to diet and blood cholesterol.

  9. Accelerated partial-breast irradiation with interstitial implants. The clinical relevance of the calculation of skin doses

    International Nuclear Information System (INIS)

    Ott, O.J.; Lotter, M.; Sauer, R.; Strnad, V.

    2007-01-01

    Purpose: To describe relative skin dose estimations and their impact on cosmetic outcome in interstitial multicatheter accelerated partial-breast irradiation (APBI). Patients and Methods: Between April 2001 and January 2005, 105 consecutive patients with early breast cancer were recruited in Erlangen, Germany, for this substudy of the German-Austrian APBI phase II trial. 51% (54/105) received pulsed-dose-rate (PDR), and 49% (51/105) high-dose-rate (HDR) brachytherapy. Prescribed reference dose for HDR brachytherapy was 32 Gy in eight fractions of 4 Gy, twice daily. Prescribed reference dose in PDR brachytherapy was 49.8 Gy in 83 consecutive fractions of 0.6 Gy every hour. Total treatment time was 3-4 days. With a wire cross on the skin surface during the brachytherapy-planning procedure the minimal, mean and maximal relative skin doses (SD min% , SD max% , SD mean% ) were recorded. Endpoint of this evaluation was the cosmetic outcome in relation to the relative skin doses. Results: Median follow-up time was 38 months (range, 19-65 months). Cosmetic results for all patients were excellent in 57% (60/105), good in 36% (38/105), and fair in 7% (7/105). The SD min% (27.0% vs. 31.7%; p = 0.032), SD mean% (34.2% vs. 38.1%; p 0.008), and SD max% (38.2% vs. 46.4%; p 0.003) were significantly lower for patients with excellent cosmetic outcome compared to patients with a suboptimal outcome. SD mean% (37.6% vs. 34.2%; p = 0.026) and SD max% (45.4% vs. 38.2%; p = 0.008) were significantly higher for patients with good cosmetic outcome compared with the patients with excellent results. Conclusion: The appraisal of skin doses has been shown to be relevant to the achievement of excellent cosmetic outcome. Further investigations are necessary, especially on the basis of CT-based brachytherapy planning, to further improve the treatment results of multicatheter APBI. (orig.)

  10. Preimplantation of an immunoprotective device can lower the curative dose of islets to that of free islet transplantation: studies in a rodent model.

    Science.gov (United States)

    Sörenby, Anne K; Kumagai-Braesch, Makiko; Sharma, Amit; Hultenby, Kjell R; Wernerson, Annika M; Tibell, Annika B

    2008-07-27

    Islet graft survival inside macroencapsulation devices is suboptimal. We hypothesized that induction of neovascularization by preimplantation of devices would improve the physiological conditions, thereby lowering the number of islets required for cure. Several rat islets were transplanted to TheraCyte immunoprotective devices implanted subcutaneously in diabetic athymic mice. Cure rates in the groups with preimplanted devices were significantly better than in those with freshly implanted devices (375 islets: 8/8 vs. 1/6, P=0.003; 125 islets: 6/6 vs. 0/7, P=0.001). Morphometric evaluations of the 125 islet groups showed higher fractional and absolute volumes of endocrine tissue in the group with preimplanted devices (P<0.001 and P=0.035, respectively). In the following dose titration study, using preimplanted devices, as low as 50 islets cured diabetic mice (100% cure, n=6). We conclude that preimplantation significantly lowers the curative dose of macroencapsulated islets to levels resembling those of free islets transplanted under the renal capsule.

  11. Radioprotection of whole-body gamma irradiation induced alterations in lipid metabolism of liver and plasma by AET (S-2, aminoethyl isothiuronium Br. H. Br.) and serotonin in rats

    International Nuclear Information System (INIS)

    Ramanathan, R.; Misra, U.K.

    1975-01-01

    Radioprotective effect of AET, serotonin and their mixture has been studied on liver and plasma lipid metabolism 24 hrs and 48 hrs after irradiation in fasted male rats. AET and serotonin both gave significant radioprotection to certain liver and plasma lipid components, but the mixture of the two afforded a better protection. The non-radioprotection of plasma NEFA, phospholipids and phosphatidyl choline levels by serotonin observed in irradiated rats was because serotonin itself raised the levels of these lipids in control rats. Serotonin alone or in mixture effectively protected the radiation-induced increased incorporation of NaH 2 32 PO 4 into liver phospholipids. Mixture of AET and serotonin failed to protect the increased incorporation of aceae-1-14-C into liver total fatty acids and cholesterol, but it prevented this increased incorporation into liver triglycerides and phospholipids. (orig.) [de

  12. Effect of Female Body Mass Index on Oocyte Quantity in Fertility Treatments (IVF): Treatment Cycle Number Is a Possible Effect Modifier. A Register-Based Cohort Study

    DEFF Research Database (Denmark)

    Christensen, Mette Wulf; Ingerslev, Hans Jakob; Degn, Birte

    2016-01-01

    linear regressions analyses were performed accounting for the non-independence of ≥2 cycles in a woman. RESULTS: Stratification according to cycle number revealed a more suboptimal outcome in the first treatment- cycles than in the following cycles, suggesting a possible interaction or effect......INTRODUCTION: Overweight and obese women may require higher doses of gonadotrophin when undergoing In Vitro Fertilization Treatment (IVF). Consequently, one may expect a sub-optimal oocyte retrieval in the first treatment cycle and thus a larger compensation in gonadotrophin-dose in the following...

  13. Prostate Dose Escalation by Innovative Inverse Planning-Driven IMRT

    National Research Council Canada - National Science Library

    Xing, Lei

    2005-01-01

    .... Because of the tacit ignorance of intra-structural tradeoff, the IMRT plans generated by these systems for prostate treatment are, at best, sub-optimal and our endeavor of providing the best possible...

  14. Sunk cost and work ethic effects reflect suboptimal choice between different work requirements.

    Science.gov (United States)

    Magalhães, Paula; White, K Geoffrey

    2013-03-01

    We investigated suboptimal choice between different work requirements in pigeons (Columba livia), namely the sunk cost effect, an irrational tendency to persist with an initial investment, despite the availability of a better option. Pigeons chose between two keys, one with a fixed work requirement to food of 20 pecks (left key), and the other with a work requirement to food which varied across conditions (center key). On some trials within each session, such choices were preceded by an investment of 35 pecks on the center key, whereas on others they were not. On choice trials preceded by the investment, the pigeons tended to stay and complete the schedule associated with the center key, even when the number of pecks to obtain reward was greater than for the concurrently available left key. This result indicates that pigeons, like humans, commit the sunk cost effect. With higher work requirements, this preference was extended to trials where there was no initial investment, so an overall preference for the key associated with more work was evident, consistent with the work ethic effect. We conclude that a more general work ethic effect is amplified by the effect of the prior investment, that is, the sunk cost effect. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Phase I Trial of Pelvic Nodal Dose Escalation With Hypofractionated IMRT for High-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Adkison, Jarrod B.; McHaffie, Derek R.; Bentzen, Soren M.; Patel, Rakesh R.; Khuntia, Deepak [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Petereit, Daniel G. [Department of Radiation Oncology, John T. Vucurevich Regional Cancer Care Institute, Rapid City Regional Hospital, Rapid City, SD (United States); Hong, Theodore S.; Tome, Wolfgang [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Ritter, Mark A., E-mail: ritter@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States)

    2012-01-01

    Purpose: Toxicity concerns have limited pelvic nodal prescriptions to doses that may be suboptimal for controlling microscopic disease. In a prospective trial, we tested whether image-guided intensity-modulated radiation therapy (IMRT) can safely deliver escalated nodal doses while treating the prostate with hypofractionated radiotherapy in 5 Vulgar-Fraction-One-Half weeks. Methods and Materials: Pelvic nodal and prostatic image-guided IMRT was delivered to 53 National Comprehensive Cancer Network (NCCN) high-risk patients to a nodal dose of 56 Gy in 2-Gy fractions with concomitant treatment of the prostate to 70 Gy in 28 fractions of 2.5 Gy, and 50 of 53 patients received androgen deprivation for a median duration of 12 months. Results: The median follow-up time was 25.4 months (range, 4.2-57.2). No early Grade 3 Radiation Therapy Oncology Group or Common Terminology Criteria for Adverse Events v.3.0 genitourinary (GU) or gastrointestinal (GI) toxicities were seen. The cumulative actuarial incidence of Grade 2 early GU toxicity (primarily alpha blocker initiation) was 38%. The rate was 32% for Grade 2 early GI toxicity. None of the dose-volume descriptors correlated with GU toxicity, and only the volume of bowel receiving {>=}30 Gy correlated with early GI toxicity (p = 0.029). Maximum late Grades 1, 2, and 3 GU toxicities were seen in 30%, 25%, and 2% of patients, respectively. Maximum late Grades 1 and 2 GI toxicities were seen in 30% and 8% (rectal bleeding requiring cautery) of patients, respectively. The estimated 3-year biochemical control (nadir + 2) was 81.2 {+-} 6.6%. No patient manifested pelvic nodal failure, whereas 2 experienced paraaortic nodal failure outside the field. The six other clinical failures were distant only. Conclusions: Pelvic IMRT nodal dose escalation to 56 Gy was delivered concurrently with 70 Gy of hypofractionated prostate radiotherapy in a convenient, resource-efficient, and well-tolerated 28-fraction schedule. Pelvic nodal dose

  16. Dose specification for radiation therapy: dose to water or dose to medium?

    International Nuclear Information System (INIS)

    Ma, C-M; Li Jinsheng

    2011-01-01

    The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy deposition in different media and expresses dose to a medium. This paper discusses the differences in dose calculated using water with different electron densities and that calculated for different biological media and the clinical issues on dose specification including dose prescription and plan evaluation using dose to water and dose to medium. We will demonstrate that conventional photon dose calculation algorithms compute doses similar to those simulated by Monte Carlo using water with different electron densities, which are close (<4% differences) to doses to media but significantly different (up to 11%) from doses to water converted from doses to media following American Association of Physicists in Medicine (AAPM) Task Group 105 recommendations. Our results suggest that for consistency with previous radiation therapy experience Monte Carlo photon algorithms report dose to medium for radiotherapy dose prescription, treatment plan evaluation and treatment outcome analysis.

  17. Suboptimal Iodine Concentration in Breastmilk and Inadequate Iodine Intake among Lactating Women in Norway.

    Science.gov (United States)

    Henjum, Sigrun; Lilleengen, Anne Marie; Aakre, Inger; Dudareva, Anna; Gjengedal, Elin Lovise Folven; Meltzer, Helle Margrete; Brantsæter, Anne Lise

    2017-06-22

    Breastfed infants depend on sufficient maternal iodine intake for optimal growth and neurological development. Despite this, few studies have assessed iodine concentrations in human milk and there is currently no published data on iodine status among lactating women in Norway. The aim of this study was to assess iodine concentrations in breast milk (BMIC) in lactating women and estimate iodine intake. Five Mother and Child Health Centres in Oslo were randomly selected during 2016, and 175 lactating women between 2nd and 28th weeks postpartum participated. Each of the women provided four breastmilk samples which were pooled and analysed for iodine concentrations. Participants also provided information on iodine intake from food and supplements covering the last 24 h and the habitual iodine intake (food frequency questionnaire). The median (p25, p75 percentiles) BMIC was 68 (45, 98) µg/L and 76% had BMIC food (p25, p75) was 121 (82, 162) µg/day and the total intake (food and supplements) was 134 (95, 222) µg/day. The majority of lactating women had suboptimal BMIC and inadequate intake of iodine from food and supplements.

  18. A Complier Average Causal Effect Analysis of the Stimulant Reduction Intervention using Dosed Exercise Study.

    Science.gov (United States)

    Carmody, Thomas; Greer, Tracy L; Walker, Robrina; Rethorst, Chad D; Trivedi, Madhukar H

    2018-06-01

    Exercise is a promising treatment for substance use disorders, yet an intention-to-treat analysis of a large, multi-site study found no reduction in stimulant use for exercise versus health education. Exercise adherence was sub-optimal; therefore, secondary post-hoc complier average causal effects (CACE) analysis was conducted to determine the potential effectiveness of adequately dosed exercise. The STimulant use Reduction Intervention using Dosed Exercise study was a randomized controlled trial comparing a 12 kcal/kg/week (KKW) exercise dose versus a health education control conducted at nine residential substance use treatment settings across the U.S. that are affiliated with the National Drug Abuse Treatment Clinical Trials Network. Participants were sedentary but medically approved for exercise, used stimulants within 30 days prior to study entry, and received a DSM-IV stimulant abuse or dependence diagnosis within the past year. A CACE analysis adjusted to include only participants with a minimum threshold of adherence (at least 8.3 KKW) and using a negative-binomial hurdle model focused on 218 participants who were 36.2% female, mean age 39.4 years ( SD =11.1), and averaged 13.0 ( SD =9.2) stimulant use days in the 30 days before residential treatment. The outcome was days of stimulant use as assessed by the self-reported TimeLine Follow Back and urine drug screen results. The CACE-adjusted analysis found a significantly lower probability of relapse to stimulant use in the exercise group versus the health education group (41.0% vs. 55.7%, p <.01) and significantly lower days of stimulant use among those who relapsed (5.0 days vs. 9.9 days, p <.01). The CACE adjustment revealed significant, positive effects for exercise. Further research is warranted to develop strategies for exercise adherence that can ensure achievement of an exercise dose sufficient to produce a significant treatment effect.

  19. Critical phenomena in communication/computation networks with various topologies and suboptimal to optimal resource allocation

    Science.gov (United States)

    Cogoni, Marco; Busonera, Giovanni; Anedda, Paolo; Zanetti, Gianluigi

    2015-01-01

    We generalize previous studies on critical phenomena in communication networks [1,2] by adding computational capabilities to the nodes. In our model, a set of tasks with random origin, destination and computational structure is distributed on a computational network, modeled as a graph. By varying the temperature of a Metropolis Montecarlo, we explore the global latency for an optimal to suboptimal resource assignment at a given time instant. By computing the two-point correlation function for the local overload, we study the behavior of the correlation distance (both for links and nodes) while approaching the congested phase: a transition from peaked to spread g(r) is seen above a critical (Montecarlo) temperature Tc. The average latency trend of the system is predicted by averaging over several network traffic realizations while maintaining a spatially detailed information for each node: a sharp decrease of performance is found over Tc independently of the workload. The globally optimized computational resource allocation and network routing defines a baseline for a future comparison of the transition behavior with respect to existing routing strategies [3,4] for different network topologies.

  20. Consumer perception and preference for suboptimal food under the emerging practice of expiration date based pricing in supermarkets

    DEFF Research Database (Denmark)

    Aschemann-Witzel, Jessica

    2018-01-01

    Consumers have been found to majorly prefer ‘optimal’ food over ‘suboptimal’ when purchasing food. To provide an incentive for consumers to select suboptimal food and thus decrease food waste in the supply chain, expiration date based pricing is suggested and increasingly applied. However......, it is unclear which contextual, individual, and product-related factors impact consumer likelihood of choice and thus acceptance of the practice in the long run. The study aimed at exploring the effect of communicating different motives for purchase, the product being organic, familiarity with the practice......, individual preferences, and product-related factors. An online survey experiment among 842 Danish consumers realistically mimicked the current market context. Findings reveal that neither communicating budget saving or food waste avoidance nor the product being organic has an influence. However...

  1. Dose escalation of chart in non-small cell lung cancer: is three-dimensional conformal radiation therapy really necessary?

    International Nuclear Information System (INIS)

    McGibney, Carol; Holmberg, Ola; McClean, Brendan; Williams, Charles; McCrea, Pamela; Sutton, Phil; Armstrong, John

    1999-01-01

    Purpose: To evaluate, pre clinically, the potential for dose escalation of continuous, hyperfractionated, accelerated radiation therapy (CHART) for non small-cell lung cancer (NSCLC), we examined the strategy of omission of elective nodal irradiation with and without the application of three-dimensional conformal radiation technology (3DCRT). Methods and Materials: 2D, conventional therapy plans were designed according to the specifications of CHART for 18 patients with NSCLC (Stages Ib, IIb, IIIa, and IIIb). Further plans were generated with the omission of elective nodal irradiation (ENI) from the treatment portals (2D minus ENI plans [2D-ENI plans]). Both sets were inserted in the patient's planning computed tomographies (CTs). These reconstructed plans were then compared to alternative, three-dimensional treatment plans which had been generated de novo, with the omission of ENI: 3D minus elective nodal irradiation (3D-ENI plans). Dose delivery to the planning target volumes (PTVs) and to the organs at risk were compared between the 3 sets of corresponding plans. The potential for dose escalation of each patient's 2D-ENI and 3D-ENI plan beyond 54 Gy, standard to CHART, was also determined. Results: PTV coverage was suboptimal in the 2D CHART and the 2D-ENI plans. Only in the 3D-ENI plans did 100% of the PTV get ≥95% of the dose prescribed (i.e., 51.5 Gy [51.3-52.2]). Using 3D-ENI plans significantly reduced the dose received by the spinal cord, the mean and median doses to the esophagus and the heart. It did not significantly reduce the lung dose when compared to 2D-ENI plans. Escalation of the dose (minimum ≥1 Gy) with optimal PTV coverage was possible in 55.5% of patients using 3D-ENI, but was possible only in 16.6% when using the 2D-ENI planning strategy. Conclusions: 3DCRT is fundamental to achieving optimal PTV coverage in NSCLC. A policy of omission of elective nodal irradiation alone (and using 2D technology) will not achieve optimal PTV coverage or

  2. Dose-dense chemoimmunotherapy and CNS prophylaxis in patients with high-risk DLBCL: a comparison of Nordic CRY-04 and CHIC studies

    DEFF Research Database (Denmark)

    Leppä, Sirpa; Jørgensen, Judit Meszaros; Brown, Peter De Nully

    Background: Survival of patients with high-risk diffuse large B-cell lymphoma (DLBCL) is suboptimal, and the risk of central nervous system (CNS) progression relatively high. We investigated the efficacy of dose-dense chemoimmunotherapy and systemic CNS prophylaxis in two completed Nordic trials...... including patients less than 65 years with high-risk DLBCL. We combined individual patient data from these studies to compare clinical outcome and prognostic factors in patients treated with CNS prophylaxis given in the beginning (CHIC) vs at the end (CRY-04) of therapy. Patients and methods: Inclusion...... proliferation index (Ki67 expression available PET data, Deauville score 5 at the end of treatment was associated with increased rate of progression and death in both trials (p=0.012). Only one out of 17 biopsies from PET positive...

  3. Burden of Disease Attributable to Suboptimal Breastfeeding in Iran during 1990-2010; Findings from the Global Burden of Disease Study 2010

    Directory of Open Access Journals (Sweden)

    Roya Kelishadi

    2016-09-01

    Full Text Available Background: This study uses data of the global burden of diseases (GBD study 2010 to report death, disability-adjusted life year (DALYs, years of life lived with disability (YLDs and years of life lost due to premature mortality (YLLs, attributed to suboptimal breastfeeding by age and gender during 1990 to 2010 in Iran. Materials and Methods:The GBD assessments were used, together with estimates of death and DALYs due to specific risk factors to calculate the attributed burden of each risk factor exposure compared with the theoretical-minimum-risk exposure. Uncertainties in the distribution of exposure, relative risks, and relevant outcomes were incorporated into estimates of mortality attributable and burden and were presented as 95 % uncertainty interval (UI. Results:In both genders, the age standardized DALYs rates and the age standardized death rate [(from 5 (95% UI: 2-8 to 1 (95% UI: 0-2 per 100,000 populations], attributed to breastfeeding, had a decreasing trends. The age standardized YLD rate increased from 7 (95% UI: 2-15 to 10 (95% UI: 3-23 per 100,000 populations in boys and, from 7(95% UI: 2-16 to 11(95% UI: 3-26 per 100,000 populations in girls. The YLD changes showed some variation according to age categories. For both genders, the age standardizes YLL rate decreased from 395 (95% UI: 185-681 per 100,000 populations to 111(95% UI: 42-213 per 100,000 populations. Conclusion: The burden attributed to suboptimal breastfeeding had a considerable reduction rate from 1990 to 2010. Additional studies on burden of exclusive breastfeeding with more accurate data are recommended for policies make decision.

  4. Metabonomics-Based Study of Clinical Urine Samples in Suboptimal Health with Different Syndromes

    Directory of Open Access Journals (Sweden)

    Hai-Zhen Cui

    2013-01-01

    Full Text Available Objective. To explore the urinary biochemistry features of syndromes of traditional Chinese medicine (TCM such as syndrome of stagnation of liver Qi, spleen deficiency, liver Qi stagnation, and spleen deficiency (LSSDS in sub-optimal health status (SHS. Methods. 12 cases for each syndrome group in SHS were selected, 12 subjects were used as a normal control group, and 1H NMR detection was, respectively, carried out, and the data was corrected by the orthogonal signal correction (OSC and then adopted a partial least squares (PLS method for discriminate analysis. Results. The OSC-PLS (ctr analysis results of the nuclear overhauser enhancement spectroscopy (NOESY detection indicated that the syndromes in SHS could be differentiated, and there were significant differences in the levels of metabolites of the urine samples of the four groups; the biomarkers of LSSDS in SHS were found out. The contents of citric acid (2.54 and 2.66, trimethylamineoxide (3.26, and hippuric acid (3.98, 7.54, 7.58, 7.62, 7.66, 7.82, and 7.86 in the urine samples of LSSDS group were lower than that of the normal control group. Conclusion. There are differences in the 1H-NMR metabolic spectrum of the urine samples of the four groups, and the specific metabolic products of the LSSDS in SHS can be identified from metabonomics analysis.

  5. Prostate-specific antigen density is predictive of outcome in suboptimal prostate seed brachytherapy.

    Science.gov (United States)

    Benzaquen, David; Delouya, Guila; Ménard, Cynthia; Barkati, Maroie; Taussky, Daniel

    In prostate seed brachytherapy, a D 90 of prostate-specific antigen + 2). Univariate and multivariate analyses were performed, adjusting for known prognostic factors such as D 90 and prostate-specific antigen density (PSAD) of ≥0.15 ng/mL/cm 3 , to evaluate their ability to predict BF. Median followup for patients without BF was 72 months (interquartile range 56-96). BF-free recurrence rate at 5 years was 95% and at 8 years 88%. In univariate analysis, PSAD and cancer of the prostate risk assessment score were predictive of BF. On multivariate analysis, none of the factors remained significant. The best prognosis had patients with a low PSAD (<0.15 ng/mL/cm 3 ) and an optimal implant at 30 days after implantation (as defined by D 90  ≥ 130 Gy) compared to patients with both factors unfavorable (p = 0.006). A favorable PSAD was associate with a good prognosis, independently of the D 90 (<130 Gy vs. ≥130 Gy, p = 0.7). Patients with a PSAD of <0.15 ng/mL/cm 3 have little risk of BF, even in the case of a suboptimal implant. These results need to be validated in other patients' cohorts. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    Science.gov (United States)

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Dose-volume analysis for quality assurance of interstitial brachytherapy for breast cancer

    International Nuclear Information System (INIS)

    Vicini, Frank A.; Kestin, Larry L.; Edmundson, Gregory K.; Jaffray, David A.; Wong, John W.; Kini, Vijay R.; Chen, Peter Y.; Martinez, Alvaro A.

    1999-01-01

    11-18). Despite visual verification by the treating physician that surgical clips (with an appropriate margin) were within the boundaries of the implant needles, the median proportion of the lumpectomy cavity that received the prescribed dose was only 87% (range 73-98%). With respect to the target volume, a median of only 68% (range 56-81%) of this volume received 100% of the prescribed dose. On average, the minimum dose received by at least 90% of the target volume was 22 Gy (range 17.3-26.9), which corresponds to 69% of the prescribed dose. Conclusion: Preliminary results using our new technique to evaluate implant quality with CT-based 3D dose-volume analysis appear promising. Dosimetric quality and target volume coverage can be concurrently analyzed, allowing the possibility of evaluating implants prospectively. Considering that target volume coverage may be suboptimal even after radiographically verifying accurate implant placement, techniques similar to this need to be developed to ultimately determine the true efficacy of brachytherapy in the management of breast cancer

  8. The role of infection models and PK/PD modelling for optimising care of critically ill patients with severe infections

    NARCIS (Netherlands)

    Tangden, T.; Martin, V.; Felton, T.W.; Nielsen, E.I.; Marchand, S.; Bruggemann, R.J.M.; Bulitta, J.B.; Bassetti, M.; Theuretzbacher, U.; Tsuji, B.T.; Wareham, D.W.; Friberg, L.E.; Waele, J.J. De; Tam, V.H.; Roberts, J.A.

    2017-01-01

    Critically ill patients with severe infections are at high risk of suboptimal antimicrobial dosing. The pharmacokinetics (PK) and pharmacodynamics (PD) of antimicrobials in these patients differ significantly from the patient groups from whose data the conventional dosing regimens were developed.

  9. Design of a multicentre randomized controlled trial to assess the safety and efficacy of dose titration by specialized nurses in patients with heart failure. ETIFIC study protocol.

    Science.gov (United States)

    Oyanguren, Juana; García-Garrido, LLuisa; Nebot Margalef, Magdalena; Lekuona, Iñaki; Comin-Colet, Josep; Manito, Nicolás; Roure, Julia; Ruiz Rodriguez, Pilar; Enjuanes, Cristina; Latorre, Pedro; Torcal Laguna, Jesús; García-Gutiérrez, Susana

    2017-11-01

    Heart failure (HF) is associated with many hospital admissions and relatively high mortality, rates decreasing with administration of beta-blockers (BBs), angiotensin-converting-enzyme inhibitors, angiotensin II receptor blockers, and mineralocorticoid receptor antagonists. The effect is dose dependent, suboptimal doses being common in clinical practice. The 2012 European guidelines recommend close monitoring and dose titration by HF nurses. Our main aim is to compare BB doses achieved by patients after 4 months in intervention (HF nurse-managed) and control (cardiologist-managed) groups. Secondary aims include comparing doses of the other aforementioned drugs achieved after 4 months, adverse events, and outcomes at 6 months in the two groups. We have designed a multicentre (20 hospitals) non-inferiority randomized controlled trial, including patients with new-onset HF, left ventricular ejection fraction ≤40%, and New York Heart Association class II-III, with no contraindications to BBs. We will also conduct qualitative analysis to explore potential barriers to and facilitators of dose titration by HF nurses. In the intervention group, HF nurses will implement titration as prescribed by cardiologists, following a protocol. In controls, cardiologists will both prescribe and titrate doses. The study variables are doses of each of the drugs after 4 months relative to the target dose (%), New York Heart Association class, left ventricular ejection fraction, N-terminal pro B-type natriuretic peptide levels, 6 min walk distance, comorbidities, renal function, readmissions, mortality, quality of life, and psychosocial characteristics. The trial seeks to assess whether titration by HF nurses of drugs recommended in practice guidelines is safe and not inferior to direct management by cardiologists. The results could have an impact on clinical practice. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of

  10. Dose rate constants for new dose quantities

    International Nuclear Information System (INIS)

    Tschurlovits, M.; Daverda, G.; Leitner, A.

    1992-01-01

    Conceptual changes and new quantities made is necessary to reassess dose rate quantities. Calculations of the dose rate constant were done for air kerma, ambient dose equivalent and directional dose equivalent. The number of radionuclides is more than 200. The threshold energy is selected as 20 keV for the dose equivalent constants. The dose rate constant for the photon equivalent dose as used mainly in German speaking countries as a temporary quantity is also included. (Author)

  11. Influence of prebiotics on Lactobacillus reuteri death kinetics under sub-optimal temperatures and pH.

    Science.gov (United States)

    Altieri, Clelia; Iorio, Maria Clara; Bevilacqua, Antonio; Sinigaglia, Milena

    2016-01-01

    Eaten foodstuffs are usually fortified with prebiotic ingredients, such as inulin and oligofructose (FOS). The main goal of this study was to evaluate the combined effects of inulin and FOS with either suboptimal pH or storage temperature on the viability of Lactobacillus reuteri DSM 20016. Data were modeled through Weibull equation for the evaluation of the microbiological shelf life and the survival time. Prebiotics enhanced the microbiological shelf life and enhanced the survival time of the target bacterium. The use of the factorial ANOVA highlighted that inulin and FOS exerted a different effect as a function of pH and temperature. Inulin prolonged survival time under acidic conditions, while the effect of glucose + FOS was significant at pH 8. Finally, temperature could act by increasing or decreasing the effect of prebiotics, as they could exert a protective effect at 30 °C but not at 44 °C. As the main output of this research, we could suggest that the effect of prebiotics on L. reuteri could be significantly affected by pH and temperature, thus pinpointing that the design of a symbiotic food should also rely on these factors.

  12. [Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].

    Science.gov (United States)

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.

  13. Dose-dependent social-cognitive effects of intranasal oxytocin delivered with novel Breath Powered device in adults with autism spectrum disorder: a randomized placebo-controlled double-blind crossover trial.

    Science.gov (United States)

    Quintana, D S; Westlye, L T; Hope, S; Nærland, T; Elvsåshagen, T; Dørum, E; Rustan, Ø; Valstad, M; Rezvaya, L; Lishaugen, H; Stensønes, E; Yaqub, S; Smerud, K T; Mahmoud, R A; Djupesland, P G; Andreassen, O A

    2017-05-23

    The neuropeptide oxytocin has shown promise as a treatment for symptoms of autism spectrum disorders (ASD). However, clinical research progress has been hampered by a poor understanding of oxytocin's dose-response and sub-optimal intranasal delivery methods. We examined two doses of oxytocin delivered using a novel Breath Powered intranasal delivery device designed to improve direct nose-to-brain activity in a double-blind, crossover, randomized, placebo-controlled trial. In a randomized sequence of single-dose sessions, 17 male adults with ASD received 8 international units (IU) oxytocin, 24IU oxytocin or placebo followed by four social-cognitive tasks. We observed an omnibus main effect of treatment on the primary outcome measure of overt emotion salience as measured by emotional ratings of faces (η 2 =0.18). Compared to placebo, 8IU treatment increased overt emotion salience (P=0.02, d=0.63). There was no statistically significant increase after 24IU treatment (P=0.12, d=0.4). The effects after 8IU oxytocin were observed despite no significant increase in peripheral blood plasma oxytocin concentrations. We found no significant effects for reading the mind in the eyes task performance or secondary outcome social-cognitive tasks (emotional dot probe and face-morphing). To our knowledge, this is the first trial to assess the dose-dependent effects of a single oxytocin administration in autism, with results indicating that a low dose of oxytocin can significantly modulate overt emotion salience despite minimal systemic exposure.

  14. Suboptimal Nutritional Characteristics in Male and Female Soldiers Compared to Sports Nutrition Guidelines.

    Science.gov (United States)

    Beals, Kim; Darnell, Matthew E; Lovalekar, Mita; Baker, Rachel A; Nagai, Takashi; San-Adams, Thida; Wirt, Michael D

    2015-12-01

    The purpose of this study was to evaluate the nutrient intake of male and female Soldiers in the 101 st Airborne Division (Air Assault) compared to sports nutrition standards for athletes, and to identify suboptimal eating characteristics that may impair physical performance and jeopardize military readiness. Male and female Soldiers from the 101 st Airborne Division (Air Assault) completed a 24-hour dietary recall and nutrition history questionnaire before anthropometric and body composition measurements were taken. Compared to sports nutrition guidelines, Soldiers of the 101 st under consume carbohydrates (males: 3.9 ± 2.0 vs. 5.0 g/kg, p < 0.001; females: 4.0 ± 2.1 vs. 5.0 g/kg, p = 0.001), male Soldiers eat too much fat (32.4% of kcal vs. <30% of kcal, p = 0.000) and saturated fat (males: 10.5 ± 3.9% of kcal vs. 10.0% of kcal, p = 0.044), and both males and females follow a meal pattern that may not optimize energy availability throughout the day. Eating too much fat and under fueling carbohydrate may negatively impact the adaptations to physical training and compromise overall health. Although Soldiers continue to participate in arduous training programs, future research should be aimed at determining the energy and macronutrient needs to fuel and recover from specific types of military training. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.

  15. Precision Hypofractionated Radiation Therapy in Poor Performing Patients With Non-Small Cell Lung Cancer: Phase 1 Dose Escalation Trial

    Energy Technology Data Exchange (ETDEWEB)

    Westover, Kenneth D. [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Loo, Billy W. [Department of Radiation Oncology, Stanford University, Stanford, California (United States); Gerber, David E. [Division of Hematology-Oncology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Iyengar, Puneeth; Choy, Hak [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Diehn, Maximilian [Department of Radiation Oncology, Stanford University, Stanford, California (United States); Hughes, Randy; Schiller, Joan; Dowell, Jonathan [Division of Hematology-Oncology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Wardak, Zabi [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Sher, David [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States); Christie, Alana; Xie, Xian-Jin [Department of Clinical Science, Southwestern Medical Center, Dallas, Texas (United States); Corona, Irma [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Sharma, Akanksha [School of Medicine, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Wadsworth, Margaret E. [Radiation Oncology of Mississippi, Jackson, Mississippi (United States); Timmerman, Robert, E-mail: Robert.Timmerman@utsouthwestern.edu [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States)

    2015-09-01

    Purpose: Treatment regimens for locally advanced non-small cell lung cancer (NSCLC) give suboptimal clinical outcomes. Technological advancements such as radiation therapy, the backbone of most treatment regimens, may enable more potent and effective therapies. The objective of this study was to escalate radiation therapy to a tumoricidal hypofractionated dose without exceeding the maximally tolerated dose (MTD) in patients with locally advanced NSCLC. Methods and Materials: Patients with stage II to IV or recurrent NSCLC and Eastern Cooperative Oncology Group performance status of 2 or greater and not candidates for surgical resection, stereotactic radiation, or concurrent chemoradiation were eligible. Highly conformal radiation therapy was given to treat intrathoracic disease in 15 fractions to a total of 50, 55, or 60 Gy. Results: Fifty-five patients were enrolled: 15 at the 50-Gy, 21 at the 55-Gy, and 19 at the 60-Gy dose levels. A 90-day follow-up was completed in each group without exceeding the MTD. With a median follow-up of 12.5 months, there were 93 grade ≥3 adverse events (AEs), including 39 deaths, although most AEs were considered related to factors other than radiation therapy. One patient from the 55- and 60-Gy dose groups developed grade ≥3 esophagitis, and 5, 4, and 4 patients in the respective dose groups experienced grade ≥3 dyspnea, but only 2 of these AEs were considered likely related to therapy. There was no association between fraction size and toxicity (P=.24). The median overall survival was 6 months with no significant differences between dose levels (P=.59). Conclusions: Precision hypofractionated radiation therapy consisting of 60 Gy in 15 fractions for locally advanced NSCLC is generally well tolerated. This treatment regimen could provide patients with poor performance status a potent alternative to chemoradiation. This study has implications for the cost effectiveness of lung cancer therapy. Additional studies of long

  16. Pharmacology of milrinone in neonates with persistent pulmonary hypertension of the newborn and suboptimal response to inhaled nitric oxide.

    Science.gov (United States)

    McNamara, Patrick J; Shivananda, Sandesh P; Sahni, Mohit; Freeman, David; Taddio, Anna

    2013-01-01

    Persistent pulmonary hypertension of the newborn is a common problem with significant morbidity and mortality. Inhaled nitric oxide is the standard care, but up to 40% of neonates are nonresponders. Milrinone is a phosphodiesterase III inhibitor which increases the bioavailability of cyclic adenosine monophosphate and has been shown to improve pulmonary hemodynamics in animal experimental models. The primary objective was to investigate the pharmacological profile of milrinone in persistent pulmonary hypertension of the newborn. Secondary objectives were to delineate short-term outcomes and safety profile. An open label study of milrinone in neonates with persistent pulmonary hypertension of the newborn was conducted. Patients received an intravenous loading dose of milrinone (50 μg/kg) over 60 mins followed by a maintenance infusion (0.33-0.99 μg/kg/min) for 24-72 hrs. Physiologic indices of cardiorespiratory stability and details of cointerventions were recorded. Serial blood milrinone levels were collected after the bolus, following initiation of the maintenance infusion to determine steady state levels, and following discontinuation of the drug to determine clearance. Echocardiography was performed before and after (1, 12 hrs) milrinone initiation. Milrinone. Eleven neonates with a diagnosis of persistent pulmonary hypertension of the newborn who met eligibility criteria were studied. The median (SD) gestational age and weight at birth were 39.2 ± 1.3 wks and 3481 ± 603 g. The mean (± sd) half-life, total body clearance, volume of distribution, and steady state concentration of milrinone were 4.1 ± 1.1 hrs, 0.11 ± 0.01 L/kg/hr, 0.56 ± 0.19 L/kg, and 290.9 ± 77.7 ng/mL. The initiation of milrinone led to an improvement in PaO2 (p = 0.002) and a sustained reduction in FIO2 (p milrinone treatment. The pharmacokinetics of milrinone in persistent pulmonary hypertension of the newborn is consistent with published data. The administration of intravenous

  17. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  18. Factors associated with suboptimal adherence to antiretroviral therapy in Asia

    Science.gov (United States)

    Jiamsakul, Awachana; Kumarasamy, Nagalingeswaran; Ditangco, Rossana; Li, Patrick CK; Phanuphak, Praphan; Sirisanthana, Thira; Sungkanuparph, Somnuek; Kantipong, Pacharee; Lee, Christopher KC; Mustafa, Mahiran; Merati, Tuti; Kamarulzaman, Adeeba; Singtoroj, Thida; Law, Matthew

    2014-01-01

    Introduction Adherence to antiretroviral therapy (ART) plays an important role in treatment outcomes. It is crucial to identify factors influencing adherence in order to optimize treatment responses. The aim of this study was to assess the rates of, and factors associated with, suboptimal adherence (SubAdh) in the first 24 months of ART in an Asian HIV cohort. Methods As part of a prospective resistance monitoring study, the TREAT Asia Studies to Evaluate Resistance Monitoring Study (TASER-M) collected patients’ adherence based on the World Health Organization-validated Adherence Visual Analogue Scale. SubAdh was defined in two ways: (i) 14 days. Time was divided into four intervals: 0–6, 6–12, 12–18 and 18–24 months. Factors associated with SubAdh were analysed using generalized estimating equations. Results Out of 1316 patients, 32% ever reported 2 assessments per patient per year had an odds ratio (OR)=0.7 (95% confidence interval (CI) (0.55 to 0.90), p=0.006), compared to sites with ≤2 assessments per patient per year. Compared to heterosexual exposure, SubAdh was higher in injecting drug users (IDUs) (OR=1.92, 95% CI (1.23 to 3.00), p=0.004) and lower in homosexual exposure (OR=0.52, 95% CI (0.38 to 0.71), p<0.001). Patients taking a nucleoside transcriptase inhibitor and protease inhibitor (NRTI+PI) combination were less likely to report adherence <100% (OR=0.36, 95% CI (0.20 to 0.67), p=0.001) compared to patients taking an NRTI and non-nucleoside transcriptase inhibitor (NRTI+NNRTI) combination. SubAdh decreased with increasing time on ART (all p<0.001). Similar associations were found with adherence <95% as the outcome. Conclusions We found that SubAdh, defined as either <100% and <95%, was associated with mode of HIV exposure, ART regimen, time on ART and frequency of adherence measurement. The more frequently sites assessed patients, the lower the SubAdh, possibly reflecting site resourcing for patient counselling. Although social

  19. From personnel dose to personal dose

    International Nuclear Information System (INIS)

    Hoefert, M.; Raffnsoe, R.C.; Tuyn, J.W.N.; Wittekind, D.

    1985-01-01

    From following the development of personnel doses at CERN over the past six years it has become evident that work in areas of induced radioactivity is the principal cause of exposure. The results of photon dose measurements free-in-air and around a phantom are presented and discussed in the light of new quantities in individual monitoring. The importance of these results, with respect to the practical situation, is discussed and the problem of phantom size is mentioned. Finally, the results of dose measurements in the phantom are presented, since such information is important in cases where it becomes necessary to transform personnel doses into personal doses. (author)

  20. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    International Nuclear Information System (INIS)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  1. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    Science.gov (United States)

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  2. Suboptimal decision making by children with ADHD in the face of risk: Poor risk adjustment and delay aversion rather than general proneness to taking risks.

    Science.gov (United States)

    Sørensen, Lin; Sonuga-Barke, Edmund; Eichele, Heike; van Wageningen, Heidi; Wollschlaeger, Daniel; Plessen, Kerstin Jessica

    2017-02-01

    Suboptimal decision making in the face of risk (DMR) in children with attention-deficit hyperactivity disorder (ADHD) may be mediated by deficits in a number of different neuropsychological processes. We investigated DMR in children with ADHD using the Cambridge Gambling Task (CGT) to distinguish difficulties in adjusting to changing probabilities of choice outcomes (so-called risk adjustment) from general risk proneness, and to distinguish these 2 processes from delay aversion (the tendency to choose the least delayed option) and impairments in the ability to reflect on choice options. Based on previous research, we predicted that suboptimal performance on this task in children with ADHD would be primarily relate to problems with risk adjustment and delay aversion rather than general risk proneness. Drug naïve children with ADHD (n = 36), 8 to 12 years, and an age-matched group of typically developing children (n = 34) performed the CGT. As predicted, children with ADHD were not more prone to making risky choices (i.e., risk proneness). However, they had difficulty adjusting to changing risk levels and were more delay aversive-with these 2 effects being correlated. Our findings add to the growing body of evidence that children with ADHD do not favor risk taking per se when performing gambling tasks, but rather may lack the cognitive skills or motivational style to appraise changing patterns of risk effectively. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  3. The burden of suboptimal breastfeeding in the United States: a pediatric cost analysis.

    Science.gov (United States)

    Bartick, Melissa; Reinhold, Arnold

    2010-05-01

    A 2001 study revealed that $3.6 billion could be saved if breastfeeding rates were increased to levels of the Healthy People objectives. It studied 3 diseases and totaled direct and indirect costs and cost of premature death. The 2001 study can be updated by using current breastfeeding rates and adding additional diseases analyzed in the 2007 breastfeeding report from the Agency for Healthcare Research and Quality. Using methods similar to those in the 2001 study, we computed current costs and compared them to the projected costs if 80% and 90% of US families could comply with the recommendation to exclusively breastfeed for 6 months. Excluding type 2 diabetes (because of insufficient data), we conducted a cost analysis for all pediatric diseases for which the Agency for Healthcare Research and Quality reported risk ratios that favored breastfeeding: necrotizing enterocolitis, otitis media, gastroenteritis, hospitalization for lower respiratory tract infections, atopic dermatitis, sudden infant death syndrome, childhood asthma, childhood leukemia, type 1 diabetes mellitus, and childhood obesity. We used 2005 Centers for Disease Control and Prevention breastfeeding rates and 2007 dollars. If 90% of US families could comply with medical recommendations to breastfeed exclusively for 6 months, the United States would save $13 billion per year and prevent an excess 911 deaths, nearly all of which would be in infants ($10.5 billion and 741 deaths at 80% compliance). Current US breastfeeding rates are suboptimal and result in significant excess costs and preventable infant deaths. Investment in strategies to promote longer breastfeeding duration and exclusivity may be cost-effective.

  4. Altered Innate Immune Responses in Neutrophils from Patients with Well- and Suboptimally Controlled Asthma

    Directory of Open Access Journals (Sweden)

    Francesca S. M. Tang

    2015-01-01

    Full Text Available Background. Respiratory infections are a major cause of asthma exacerbations where neutrophilic inflammation dominates and is associated with steroid refractory asthma. Structural airway cells in asthma differ from nonasthmatics; however it is unknown if neutrophils differ. We investigated neutrophil immune responses in patients who have good (AGood and suboptimal (ASubopt asthma symptom control. Methods. Peripheral blood neutrophils from AGood (ACQ 0.75, n=7, and healthy controls (HC (n=9 were stimulated with bacterial (LPS (1 μg/mL, fMLF (100 nM, and viral (imiquimod (3 μg/mL, R848 (1.5 μg/mL, and poly I:C (10 μg/mL surrogates or live rhinovirus (RV 16 (MOI1. Cell-free supernatant was collected after 1 h for neutrophil elastase (NE and matrix metalloproteinase- (MMP- 9 measurements or after 24 h for CXCL8 release. Results. Constitutive NE was enhanced in AGood neutrophils compared to HC. fMLF stimulated neutrophils from ASubopt but not AGood produced 50% of HC levels. fMLF induced MMP-9 was impaired in ASubopt and AGood compared to HC. fMLF stimulated CXCL8 but not MMP-9 was positively correlated with FEV1 and FEV1/FVC. ASubopt and AGood responded similarly to other stimuli. Conclusions. Circulating neutrophils are different in asthma; however, this is likely to be related to airflow limitation rather than asthma control.

  5. Economic and disease burden of breast cancer associated with suboptimal breastfeeding practices in Mexico.

    Science.gov (United States)

    Unar-Munguía, Mishel; Meza, Rafael; Colchero, M Arantxa; Torres-Mejía, Gabriela; de Cosío, Teresita Gonzalez

    2017-12-01

    Exclusive breastfeeding and longer breastfeeding reduce women's breast cancer risk but Mexico has one of the lowest breastfeeding rates worldwide. We estimated the lifetime economic and disease burden of breast cancer in Mexico if 95% of parous women breastfeed each child exclusively for 6 months and continue breastfeeding for over a year. We used a static microsimulation model with a cost-of-illness approach to simulate a cohort of Mexican women. We estimated breast cancer incidence, premature mortality, disability-adjusted life years (DALYs), medical costs, and income losses due to breast cancer and extrapolated the results to 1.116 million Mexican women of age 15 in 2012. Costs were expressed in 2015 US dollars and discounted at a 3% annual rate. We estimated that 2,186 premature deaths (95% CI 2,123-2,248), 9,936 breast cancer cases (95% CI 9,651-10,220), 45,109 DALYs (95% CI 43,000-47,217), and $245 million USD (95% CI 234-256) in medical costs and income losses owing to breast cancer could be saved over a cohort's lifetime. Medical costs account for 80% of the economic burden; income losses and opportunity costs for caregivers account for 15 and 5%, respectively. In Mexico, the burden of breast cancer due to suboptimal breastfeeding in women is high in terms of morbidity, premature mortality, and the economic costs for the health sector and society.

  6. Dose planning and dose delivery in radiation therapy

    International Nuclear Information System (INIS)

    Knoeoes, T.

    1991-01-01

    A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related variance contributions, making an objective evaluation of dose calculations with experiments feasible. The methods for electron density determination, dose calculation and prediction of accelerator output discussed in this study will all contribute to an increased accuracy in the mean absorbed dose to the target volume. However, a substantial gain in the accuracy for the spatial absorbed dose distribution will also follow, especially using CT for mapping of electron density together with the dose calculation algorithm. (au)

  7. Normal tissue dose-effect models in biological dose optimisation

    International Nuclear Information System (INIS)

    Alber, M.

    2008-01-01

    Sophisticated radiotherapy techniques like intensity modulated radiotherapy with photons and protons rely on numerical dose optimisation. The evaluation of normal tissue dose distributions that deviate significantly from the common clinical routine and also the mathematical expression of desirable properties of a dose distribution is difficult. In essence, a dose evaluation model for normal tissues has to express the tissue specific volume effect. A formalism of local dose effect measures is presented, which can be applied to serial and parallel responding tissues as well as target volumes and physical dose penalties. These models allow a transparent description of the volume effect and an efficient control over the optimum dose distribution. They can be linked to normal tissue complication probability models and the equivalent uniform dose concept. In clinical applications, they provide a means to standardize normal tissue doses in the face of inevitable anatomical differences between patients and a vastly increased freedom to shape the dose, without being overly limiting like sets of dose-volume constraints. (orig.)

  8. Harm, benefit and costs associated with low-dose glucocorticoids added to the treatment strategies for rheumatoid arthritis in elderly patients (GLORIA trial)

    DEFF Research Database (Denmark)

    Hartman, Linda; Rasch, Linda A; Klausch, Thomas

    2018-01-01

    experience, there is a lack of studies large enough to adequately document the benefit/harm balance. The result is inappropriate treatment strategies, i.e. both under-use and over-use of GCs, and consequently suboptimal treatment of RA. METHODS: The GLORIA study is a pragmatic multicentre, 2-year, randomised......, double-blind, clinical trial to assess the safety and effectiveness of a daily dose of 5 mg prednisolone or matching placebo added to standard of care in elderly patients with RA. Eligible participants are diagnosed with RA, have inadequate disease control (disease activity score, DAS28 ≥ 2...... on daily practice and maximise clinical relevance of the results, but analysis and interpretation of the results is challenging. We expect that the results of this trial are of importance for all rheumatologists who treat elderly patients with RA. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02585258...

  9. Suboptimal Addiction Interventions for Patients Hospitalized with Injection Drug Use-Associated Infective Endocarditis.

    Science.gov (United States)

    Rosenthal, Elana S; Karchmer, Adolf W; Theisen-Toupal, Jesse; Castillo, Roger Araujo; Rowley, Chris F

    2016-05-01

    Infective endocarditis is a serious infection, often resulting from injection drug use. Inpatient treatment regularly focuses on management of infection without attention to the underlying addiction. We aimed to determine the addiction interventions done in patients hospitalized with injection drug use-associated infective endocarditis. This is a retrospective review of patients hospitalized with injection drug use-associated infective endocarditis from January, 2004 through August, 2014 at a large academic tertiary care center in Boston, Massachusetts. For the initial and subsequent admissions, data were collected regarding addiction interventions, including consultation by social work, addiction clinical nurse and psychiatry, documentation of addiction in the discharge summary plan, plan for medication-assisted treatment and naloxone provision. There were 102 patients admitted with injection drug use-associated infective endocarditis, 50 patients (49.0%) were readmitted and 28 (27.5%) patients had ongoing injection drug use at readmission. At initial admission, 86.4% of patients had social work consultation, 23.7% had addiction consultation, and 24.0% had psychiatry consultation. Addiction was mentioned in 55.9% of discharge summary plans, 7.8% of patients had a plan for medication-assisted treatment, and naloxone was never prescribed. Of 102 patients, 26 (25.5%) are deceased. The median age at death was 40.9 years (interquartile range 28.7-48.7). We found that patients hospitalized with injection drug use-associated infective endocarditis had high rates of readmission, recurrent infective endocarditis and death. Despite this, addiction interventions were suboptimal. Improved addiction interventions are imperative in the treatment of injection drug use-associated infective endocarditis. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Clinical significance of suboptimal hormonal levels in men with prostate cancer treated with LHRH agonists.

    Science.gov (United States)

    Kawakami, Jun; Morales, Alvaro

    2013-01-01

    We examined the serum levels of testosterone (T) (total and bioavailable) dehydroepiandrosterone (DHEA), follicle-stimulating hormone (FSH), luteinizing hormone (LH), and prostate-specific antigen (PSA) in men receiving treatment with luteinizing hormone releasing-hormone (LHRH) agonists for metastatic prostate cancer. In doing this, we want to determine the efficacy of these agents in lowering T levels and whether a possible relationship exists between PSA values, as a surrogate measure of tumour activity, and hormone levels. This was a single centre prospective study of patients on LHRH agonists. Of all the 100 eligible patients, 31 did not qualify (10 were receiving their first injection, 13 were on intermittent hormonal therapy, 7 refused to enter the trial and 1 patient's blood sample was lost). Therefore in total, 69 patients were included in the final analysis. Each patient had their blood sample drawn immediately before the administration of a LHRH agonist. The new proposed criteria of values are more commonly found in patients with suboptimal levels of testosterone receiving LHRH analogs, but the clinical importance of this finding has not been established. There is no significant difference with respect to hormonal levels reached among patients on a variety of LHRH agonists. Total testosterone determinations should be considered in patients on LHRH agonist therapy, particularly when the PSA values begin to rise since it may lead to further beneficial hormonal manipulation.

  11. New dosing strategies for an old antibiotic: pharmacodynamics of front-loaded regimens of colistin at simulated pharmacokinetics in patients with kidney or liver disease.

    Science.gov (United States)

    Rao, Gauri G; Ly, Neang S; Haas, Curtis E; Garonzik, Samira; Forrest, Alan; Bulitta, Jurgen B; Kelchlin, Pamela A; Holden, Patricia N; Nation, Roger L; Li, Jian; Tsuji, Brian T

    2014-01-01

    Increasing evidence suggests that colistin monotherapy is suboptimal at currently recommended doses. We hypothesized that front-loading provides an improved dosing strategy for polymyxin antibiotics to maximize killing and minimize total exposure. Here, we utilized an in vitro pharmacodynamic model to examine the impact of front-loaded colistin regimens against a high bacterial density (10(8) CFU/ml) of Pseudomonas aeruginosa. The pharmacokinetics were simulated for patients with hepatic (half-life [t1/2] of 3.2 h) or renal (t1/2 of 14.8 h) disease. Front-loaded regimens (n=5) demonstrated improvement in bacterial killing, with reduced overall free drug areas under the concentration-time curve (fAUC) compared to those with traditional dosing regimens (n=14) with various dosing frequencies (every 12 h [q12h] and q24h). In the renal failure simulations, front-loaded regimens at lower exposures (fAUC of 143 mg · h/liter) obtained killing activity similar to that of traditional regimens (fAUC of 268 mg · h/liter), with an ∼97% reduction in the area under the viable count curve over 48 h. In hepatic failure simulations, front-loaded regimens yielded rapid initial killing by up to 7 log10 within 2 h, but considerable regrowth occurred for both front-loaded and traditional regimens. No regimen eradicated the high bacterial inoculum of P. aeruginosa. The current study, which utilizes an in vitro pharmacodynamic infection model, demonstrates the potential benefits of front-loading strategies for polymyxins simulating differential pharmacokinetics in patients with hepatic and renal failure at a range of doses. Our findings may have important clinical implications, as front-loading polymyxins as a part of a combination regimen may be a viable strategy for aggressive treatment of high-bacterial-burden infections.

  12. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  13. Randomized pharmacokinetic evaluation of different rifabutin doses in African HIV- infected tuberculosis patients on lopinavir/ritonavir-based antiretroviral therapy.

    Science.gov (United States)

    Naiker, Suhashni; Connolly, Cathy; Wiesner, Lubbe; Kellerman, Tracey; Reddy, Tarylee; Harries, Anthony; McIlleron, Helen; Lienhardt, Christian; Pym, Alexander

    2014-11-19

    Pharmacokinetic interactions between rifampicin and protease inhibitors (PIs) complicate the management of HIV-associated tuberculosis. Rifabutin is an alternative rifamycin, for patients requiring PIs. Recently some international guidelines have recommended a higher dose of rifabutin (150 mg daily) in combination with boosted lopinavir (LPV/r), than the previous dose of rifabutin (150 mg three times weekly {tiw}). But there are limited pharmacokinetic data evaluating the higher dose of rifabutin in combination with LPV/r. Sub-optimal dosing can lead to acquired rifamycin resistance (ARR). The plasma concentration of 25-O-desacetylrifabutin (d-RBT), the metabolite of rifabutin, increases in the presence of PIs and may lead to toxicity. Sixteen patients with TB-HIV co-infection received rifabutin 300 mg QD in combination with tuberculosis chemotherapy (initially pyrazinamide, isoniazid and ethambutol then only isoniazid), and were then randomized to receive isoniazid and LPV/r based ART with rifabutin 150 mg tiw or rifabutin 150 mg daily. The rifabutin dose with ART was switched after 1 month. Serial rifabutin and d-RBT concentrations were measured after 4 weeks of each treatment. The median AUC0-48 and Cmax of rifabutin in patients taking 150 mg rifabutin tiw was significantly reduced compared to the other treatment arms. Geometric mean ratio (90% CI) for AUC0-48 and Cmax was 0.6 (0.5-0.7) and 0.5 (0.4-0.6) for RBT 150 mg tiw compared with RBT 300 mg and 0.4 (0.4-0.4) and 0.5 (0.5-0.6) for RBT 150 mg tiw compared with 150 mg daily. 86% of patients on the tiw rifabutin arm had an AUC0-24 ART, and grade 3 neutropenia (asymptomatic) was reported in 4 patients. These events were not associated with increases in rifabutin or metabolite concentrations. A daily 150 mg dose of rifabutin in combination with LPV/r safely maintained rifabutin plasma concentrations in line with those shown to prevent ARR. ClinicalTrials.gov Identifier: NCT00640887.

  14. Ozone data assimilation with GEOS-Chem: a comparison between 3-D-Var, 4-D-Var, and suboptimal Kalman filter approaches

    Science.gov (United States)

    Singh, K.; Sandu, A.; Bowman, K. W.; Parrington, M.; Jones, D. B. A.; Lee, M.

    2011-08-01

    Chemistry transport models determine the evolving chemical state of the atmosphere by solving the fundamental equations that govern physical and chemical transformations subject to initial conditions of the atmospheric state and surface boundary conditions, e.g., surface emissions. The development of data assimilation techniques synthesize model predictions with measurements in a rigorous mathematical framework that provides observational constraints on these conditions. Two families of data assimilation methods are currently widely used: variational and Kalman filter (KF). The variational approach is based on control theory and formulates data assimilation as a minimization problem of a cost functional that measures the model-observations mismatch. The Kalman filter approach is rooted in statistical estimation theory and provides the analysis covariance together with the best state estimate. Suboptimal Kalman filters employ different approximations of the covariances in order to make the computations feasible with large models. Each family of methods has both merits and drawbacks. This paper compares several data assimilation methods used for global chemical data assimilation. Specifically, we evaluate data assimilation approaches for improving estimates of the summertime global tropospheric ozone distribution in August 2006 based on ozone observations from the NASA Tropospheric Emission Spectrometer and the GEOS-Chem chemistry transport model. The resulting analyses are compared against independent ozonesonde measurements to assess the effectiveness of each assimilation method. All assimilation methods provide notable improvements over the free model simulations, which differ from the ozonesonde measurements by about 20 % (below 200 hPa). Four dimensional variational data assimilation with window lengths between five days and two weeks is the most accurate method, with mean differences between analysis profiles and ozonesonde measurements of 1-5 %. Two sequential

  15. Determination of organ doses and effective doses in radiooncology

    International Nuclear Information System (INIS)

    Roth, J.; Martinez, A.E.

    2007-01-01

    Background and Purpose: With an increasing chance of success in radiooncology, it is necessary to estimate the risk from radiation scatter to areas outside the target volume. The cancer risk from a radiation treatment can be estimated from the organ doses, allowing a somewhat limited effective dose to be estimated and compared. Material and Methods: The doses of the radiation-sensitive organs outside the target volume can be estimated with the aid of the PC program PERIDOSE developed by van der Giessen. The effective doses are determined according to the concept of ICRP, whereby the target volume and the associated organs related to it are not taken into consideration. Results: Organ doses outside the target volume are generally < 1% of the dose in the target volume. In some cases, however, they can be as high as 3%. The effective doses during radiotherapy are between 60 and 900 mSv, depending upon the specific target volume, the applied treatment technique, and the given dose in the ICRU point. Conclusion: For the estimation of the radiation risk, organ doses in radiooncology can be calculated with the aid of the PC program PERIDOSE. While evaluating the radiation risk after ICRP, for the calculation of the effective dose, the advanced age of many patients has to be considered to prevent that, e.g., the high gonad doses do not overestimate the effective dose. (orig.)

  16. Organ or tissue doses, effective dose and collective effective dose from X-ray diagnosis, in Japan

    International Nuclear Information System (INIS)

    Murayama, Takashi; Nishizawa, Kanae; Noda, Yutaka; Kumamoto, Yoshikazu; Iwai, Kazuo.

    1996-01-01

    Effective doses and collective effective doses from X-ray diagnostic examinations were calculated on the basis of the frequency of examinations estimated by a nationwide survey and the organ or tissue doses experimentally determined. The average organ or tissue doses were determined with thermoluminescence dosimeters put at various sites of organs or tissues in an adult and a child phantom. Effective doses (effective dose equivalents) were calculated as the sum of the weighted equivalent doses in all the organs or tissues of the body. As the examples of results, the effective doses per radiographic examination were approximately 7 mGy for male, and 9 mGy for female angiocardiography, and about 3 mGy for barium meal. Annual collective effective dose from X-ray diagnostic examinations in 1986 were about 104 x 10 3 person Sv from radiography and 118 x 10 3 person Sv from fluoroscopy, with the total of 222 x 10 3 person Sv. (author)

  17. Correlations in state space can cause sub-optimal adaptation of optimal feedback control models.

    Science.gov (United States)

    Aprasoff, Jonathan; Donchin, Opher

    2012-04-01

    Control of our movements is apparently facilitated by an adaptive internal model in the cerebellum. It was long thought that this internal model implemented an adaptive inverse model and generated motor commands, but recently many reject that idea in favor of a forward model hypothesis. In theory, the forward model predicts upcoming state during reaching movements so the motor cortex can generate appropriate motor commands. Recent computational models of this process rely on the optimal feedback control (OFC) framework of control theory. OFC is a powerful tool for describing motor control, it does not describe adaptation. Some assume that adaptation of the forward model alone could explain motor adaptation, but this is widely understood to be overly simplistic. However, an adaptive optimal controller is difficult to implement. A reasonable alternative is to allow forward model adaptation to 're-tune' the controller. Our simulations show that, as expected, forward model adaptation alone does not produce optimal trajectories during reaching movements perturbed by force fields. However, they also show that re-optimizing the controller from the forward model can be sub-optimal. This is because, in a system with state correlations or redundancies, accurate prediction requires different information than optimal control. We find that adding noise to the movements that matches noise found in human data is enough to overcome this problem. However, since the state space for control of real movements is far more complex than in our simple simulations, the effects of correlations on re-adaptation of the controller from the forward model cannot be overlooked.

  18. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  19. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  20. Dose gradient curve: A new tool for evaluating dose gradient.

    Science.gov (United States)

    Sung, KiHoon; Choi, Young Eun

    2018-01-01

    Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice.

  1. Optimized dose distribution of a high dose rate vaginal cylinder

    International Nuclear Information System (INIS)

    Li Zuofeng; Liu, Chihray; Palta, Jatinder R.

    1998-01-01

    Purpose: To present a comparison of optimized dose distributions for a set of high-dose-rate (HDR) vaginal cylinders calculated by a commercial treatment-planning system with benchmark calculations using Monte-Carlo-calculated dosimetry data. Methods and Materials: Optimized dose distributions using both an isotropic and an anisotropic dose calculation model were obtained for a set of HDR vaginal cylinders. Mathematical optimization techniques available in the computer treatment-planning system were used to calculate dwell times and positions. These dose distributions were compared with benchmark calculations with TG43 formalism and using Monte-Carlo-calculated data. The same dwell times and positions were used for a quantitative comparison of dose calculated with three dose models. Results: The isotropic dose calculation model can result in discrepancies as high as 50%. The anisotropic dose calculation model compared better with benchmark calculations. The differences were more significant at the apex of the vaginal cylinder, which is typically used as the prescription point. Conclusion: Dose calculation models available in a computer treatment-planning system must be evaluated carefully to ensure their correct application. It should also be noted that when optimized dose distribution at a distance from the cylinder surface is calculated using an accurate dose calculation model, the vaginal mucosa dose becomes significantly higher, and therefore should be carefully monitored

  2. Dynamically accumulated dose and 4D accumulated dose for moving tumors

    International Nuclear Information System (INIS)

    Li Heng; Li Yupeng; Zhang Xiaodong; Li Xiaoqiang; Liu Wei; Gillin, Michael T.; Zhu, X. Ronald

    2012-01-01

    Purpose: The purpose of this work was to investigate the relationship between dynamically accumulated dose (dynamic dose) and 4D accumulated dose (4D dose) for irradiation of moving tumors, and to quantify the dose uncertainty induced by tumor motion. Methods: The authors established that regardless of treatment modality and delivery properties, the dynamic dose will converge to the 4D dose, instead of the 3D static dose, after multiple deliveries. The bounds of dynamic dose, or the maximum estimation error using 4D or static dose, were established for the 4D and static doses, respectively. Numerical simulations were performed (1) to prove the principle that for each phase, after multiple deliveries, the average number of deliveries for any given time converges to the total number of fractions (K) over the number of phases (N); (2) to investigate the dose difference between the 4D and dynamic doses as a function of the number of deliveries for deliveries of a “pulsed beam”; and (3) to investigate the dose difference between 4D dose and dynamic doses as a function of delivery time for deliveries of a “continuous beam.” A Poisson model was developed to estimate the mean dose error as a function of number of deliveries or delivered time for both pulsed beam and continuous beam. Results: The numerical simulations confirmed that the number of deliveries for each phase converges to K/N, assuming a random starting phase. Simulations for the pulsed beam and continuous beam also suggested that the dose error is a strong function of the number of deliveries and/or total deliver time and could be a function of the breathing cycle, depending on the mode of delivery. The Poisson model agrees well with the simulation. Conclusions: Dynamically accumulated dose will converge to the 4D accumulated dose after multiple deliveries, regardless of treatment modality. Bounds of the dynamic dose could be determined using quantities derived from 4D doses, and the mean dose

  3. A review of radiology staff doses and dose monitoring requirements

    International Nuclear Information System (INIS)

    Martin, C. J.

    2009-01-01

    Studies of radiation doses received during X-ray procedures by radiology, cardiology and other clinical staff have been reviewed. Data for effective dose (E), and doses to the eyes, thyroid, hands and legs have been analysed. These data have been supplemented with local measurements to determine the most exposed part of the hand for monitoring purposes. There are ranges of 60-100 in doses to individual tissues reported in the literature for similar procedures at different centres. While ranges in the doses per unit dose-area product (DAP) are between 10 and 25, large variations in dose result from differences in the sensitivity of the X-ray equipment, the type of procedure and the operator technique, but protection factors are important in maintaining dose levels as low as possible. The influence of shielding devices is significant for determining the dose to the eyes and thyroid, and the position of the operator, which depends on the procedure, is the most significant factor determining doses to the hands. A second body dosemeter worn at the level of the collar is recommended for operators with high workloads for use in assessment of effective dose and the dose to the eye. It is proposed that the third quartile values from the distributions of dose per unit DAP identified in the review might be employed in predicting the orders of magnitude of doses to the eye, thyroid and hands, based on interventional operator workloads. Such dose estimates could be employed in risk assessments when reviewing protection and monitoring requirements. A dosemeter worn on the little finger of the hand nearest to the X-ray tube is recommended for monitoring the hand. (authors)

  4. ''Low dose'' and/or ''high dose'' in radiation protection: A need to setting criteria for dose classification

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1997-01-01

    The ''low dose'' and/or ''high dose'' of ionizing radiation are common terms widely used in radiation applications, radiation protection and radiobiology, and natural radiation environment. Reading the title, the papers of this interesting and highly important conference and the related literature, one can simply raise the question; ''What are the levels and/or criteria for defining a low dose or a high dose of ionizing radiation?''. This is due to the fact that the criteria for these terms and for dose levels between these two extreme quantities have not yet been set, so that the terms relatively lower doses or higher doses are usually applied. Therefore, setting criteria for classification of radiation doses in the above mentioned areas seems a vital need. The author while realizing the existing problems to achieve this important task, has made efforts in this paper to justify this need and has proposed some criteria, in particular for the classification of natural radiation areas, based on a system of dose limitation. (author)

  5. Survival of lactic acid and chlorine dioxide treated Campylobacter jejuni under suboptimal conditions of pH, temperature and modified atmosphere

    DEFF Research Database (Denmark)

    Smigic, Nada; Rajkovic, Andreja; Nielsen, Dennis Sandris

    2010-01-01

    As mild decontamination treatments are gaining more and more interest due to increased consumer demands for fresh foods, it is of great importance to establish the influence of decontamination treatments on the subsequent bacterial behaviour under suboptimal storage conditions. For this purpose...... Campylobacter jejuni cells treated with lactic acid (LA, 3% lactic acid, pH 4.0, 2 min) or chlorine dioxide (ClO(2), 20 ppm, 2 min) were inoculated in Bolton broth (pH 6.0) and incubated under 80% O(2)/20% N(2), 80% CO(2)/20% N(2), air or micro-aerophilic (10% CO(2)/85% N(2)/5% O(2)) atmosphere, at 4 degrees C...... on their pH(i) values. The pH(i) response was independent on the surrounding atmosphere since similar distribution of the subpopulations was observed for all tested atmospheres. However, the pH(i) response was dependent on the initial decontamination treatment. The investigation of intracellular parameters...

  6. Quantitative analysis of biological responses to low dose-rate γ-radiation, including dose, irradiation time, and dose-rate

    International Nuclear Information System (INIS)

    Magae, J.; Furukawa, C.; Kawakami, Y.; Hoshi, Y.; Ogata, H.

    2003-01-01

    Full text: Because biological responses to radiation are complex processes dependent on irradiation time as well as total dose, it is necessary to include dose, dose-rate and irradiation time simultaneously to predict the risk of low dose-rate irradiation. In this study, we analyzed quantitative relationship among dose, irradiation time and dose-rate, using chromosomal breakage and proliferation inhibition of human cells. For evaluation of chromosome breakage we assessed micronuclei induced by radiation. U2OS cells, a human osteosarcoma cell line, were exposed to gamma-ray in irradiation room bearing 50,000 Ci 60 Co. After the irradiation, they were cultured for 24 h in the presence of cytochalasin B to block cytokinesis, cytoplasm and nucleus were stained with DAPI and propidium iodide, and the number of binuclear cells bearing micronuclei was determined by fluorescent microscopy. For proliferation inhibition, cells were cultured for 48 h after the irradiation and [3H] thymidine was pulsed for 4 h before harvesting. Dose-rate in the irradiation room was measured with photoluminescence dosimeter. While irradiation time less than 24 h did not affect dose-response curves for both biological responses, they were remarkably attenuated as exposure time increased to more than 7 days. These biological responses were dependent on dose-rate rather than dose when cells were irradiated for 30 days. Moreover, percentage of micronucleus-forming cells cultured continuously for more than 60 days at the constant dose-rate, was gradually decreased in spite of the total dose accumulation. These results suggest that biological responses at low dose-rate, are remarkably affected by exposure time, that they are dependent on dose-rate rather than total dose in the case of long-term irradiation, and that cells are getting resistant to radiation after the continuous irradiation for 2 months. It is necessary to include effect of irradiation time and dose-rate sufficiently to evaluate risk

  7. Calculation of dose conversion factors for doses in the fingernails to organ doses at external gamma irradiation in air

    International Nuclear Information System (INIS)

    Khailov, A.M.; Ivannikov, A.I.; Skvortsov, V.G.; Stepanenko, V.F.; Orlenko, S.P.; Flood, A.B.; Williams, B.B.; Swartz, H.M.

    2015-01-01

    Absorbed doses to fingernails and organs were calculated for a set of homogenous external gamma-ray irradiation geometries in air. The doses were obtained by stochastic modeling of the ionizing particle transport (Monte Carlo method) for a mathematical human phantom with arms and hands placed loosely along the sides of the body. The resulting dose conversion factors for absorbed doses in fingernails can be used to assess the dose distribution and magnitude in practical dose reconstruction problems. For purposes of estimating dose in a large population exposed to radiation in order to triage people for treatment of acute radiation syndrome, the calculated data for a range of energies having a width of from 0.05 to 3.5 MeV were used to convert absorbed doses in fingernails to corresponding doses in organs and the whole body as well as the effective dose. Doses were assessed based on assumed rates of radioactive fallout at different time periods following a nuclear explosion. - Highlights: • Elemental composition and density of nails were determined. • MIRD-type mathematical human phantom with arms and hands was created. • Organ doses and doses to nails were calculated for external photon exposure in air. • Effective dose and nail doses values are close for rotational and soil surface exposures.

  8. Dose/dose-rate responses of shrimp larvae to UV-B radiation

    International Nuclear Information System (INIS)

    Damkaer, D.M.

    1981-01-01

    Previous work indicated dose-rate thresholds in the effects of UV-B on the near-surface larvae of three shrimp species. Additional observations suggest that the total dose response varies with dose-rate. Below 0.002 Wm -2 sub([DNA]) irradiance no significant effect is noted in activity, development, or survival. Beyond that dose-rate threshold, shrimp larvae are significantly affected if the total dose exceeds about 85 Jm -2 sub([DNA]). Predictions cannot be made without both the dose-rate and the dose. These dose/dose-rate thresholds are compared to four-year mean dose/dose-rate solar UV-B irradiances at the experimental site, measured at the surface and calculated for 1 m depth. The probability that the shrimp larvae would receive lethal irradiance is low for the first half of the season of surface occurrence, even with a 44% increase in damaging UV radiation. (orig.)

  9. Dose/dose-rate responses of shrimp larvae to UV-B radiation

    Energy Technology Data Exchange (ETDEWEB)

    Damkaer, D.M.; Dey, D.B.; Heron, G.A.

    1981-01-01

    Previous work indicated dose-rate thresholds in the effects of UV-B on the near-surface larvae of three shrimp species. Additional observations suggest that the total dose response varies with dose-rate. Below 0.002 Wm/sup -2/sub((DNA)) irradiance no significant effect is noted in activity, development, or survival. Beyond that dose-rate threshold, shrimp larvae are significantly affected if the total dose exceeds about 85 Jm/sup -2/sub((DNA)). Predictions cannot be made without both the dose-rate and the dose. These dose/dose-rate thresholds are compared to four-year mean dose/dose-rate solar UV-B irradiances at the experimental site, measured at the surface and calculated for 1 m depth. The probability that the shrimp larvae would receive lethal irradiance is low for the first half of the season of surface occurrence, even with a 44% increase in damaging UV radiation.

  10. Neutrons in active proton therapy. Parameterization of dose and dose equivalent

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Uwe; Haelg, Roger A. [Univ. of Zurich (Switzerland). Dept. of Physics; Radiotherapy Hirslanden AG, Aarau (Switzerland); Lomax, Tony [Paul Scherrer Institute, Villigen (Switzerland). Center for Proton Therapy

    2017-08-01

    One of the essential elements of an epidemiological study to decide if proton therapy may be associated with increased or decreased subsequent malignancies compared to photon therapy is an ability to estimate all doses to non-target tissues, including neutron dose. This work therefore aims to predict for patients using proton pencil beam scanning the spatially localized neutron doses and dose equivalents. The proton pencil beam of Gantry 1 at the Paul Scherrer Institute (PSI) was Monte Carlo simulated using GEANT. Based on the simulated neutron dose and neutron spectra an analytical mechanistic dose model was developed. The pencil beam algorithm used for treatment planning at PSI has been extended using the developed model in order to calculate the neutron component of the delivered dose distribution for each treated patient. The neutron dose was estimated for two patient example cases. The analytical neutron dose model represents the three-dimensional Monte Carlo simulated dose distribution up to 85 cm from the proton pencil beam with a satisfying precision. The root mean square error between Monte Carlo simulation and model is largest for 138 MeV protons and is 19% and 20% for dose and dose equivalent, respectively. The model was successfully integrated into the PSI treatment planning system. In average the neutron dose is increased by 10% or 65% when using 160 MeV or 177 MeV instead of 138 MeV. For the neutron dose equivalent the increase is 8% and 57%. The presented neutron dose calculations allow for estimates of dose that can be used in subsequent epidemiological studies or, should the need arise, to estimate the neutron dose at any point where a subsequent secondary tumour may occur. It was found that the neutron dose to the patient is heavily increased with proton energy.

  11. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  12. Occupational dose assessment and national dose registry system in Iran

    International Nuclear Information System (INIS)

    Jafari-Zadeh, M.; Nazeri, F.; Hosseini-Pooya, S. M.; Taheri, M.; Gheshlaghi, F.; Kardan, M. R.; Babakhani, A.; Rastkhah, N.; Yousefi-Nejad, F.; Darabi, M.; Oruji, T.; Gholamali-Zadeh, Z.; Karimi-Diba, J.; Kazemi-Movahed, A. A.; Dashti-Pour, M. R.; Enferadi, A.; Jahanbakhshian, M. H.; Sadegh-Khani, M. R.

    2011-01-01

    This report presents status of external and internal dose assessment of workers and introducing the structure of National Dose Registry System of Iran (NDRSI). As well as types of individual dosemeters in use, techniques for internal dose assessment are presented. Results obtained from the International Atomic Energy Agency intercomparison programme on measurement of personal dose equivalent H p (10) and consistency of the measured doses with the delivered doses are shown. Also, implementation of dosimetry standards, establishment of quality management system, authorisation and approval procedure of dosimetry service providers are discussed. (authors)

  13. Suboptimal management of central nervous system infections in children: a multi-centre retrospective study

    Directory of Open Access Journals (Sweden)

    Kelly Christine

    2012-09-01

    Full Text Available Abstract Objective We aimed to audit the regional management of central nervous system (CNS infection in children. Methods The study was undertaken in five district general hospitals and one tertiary paediatric hospital in the Mersey region of the UK. Children admitted to hospital with a suspected CNS infection over a three month period were identified. Children were aged between 4 weeks and 16 years old. Details were recorded from the case notes and electronic records. We measured the appropriateness of management pathways as outlined by national and local guidelines. Results Sixty-five children were identified with a median age of 6 months (range 1 month to 15 years. Ten had a CNS infection: 4 aseptic meningitis, 3 purulent meningitis, 3 encephalitis [2 with herpes simplex virus (HSV type 1]. A lumbar puncture (LP was attempted in 50 (77% cases but only 43 had cerebrospinal fluid (CSF available for analysis. Of these 24 (57% had a complete standard set of tests performed. Fifty eight (89% received a third generation cephalosporin. Seventeen (26% also received aciclovir with no obvious indication in 9 (53%. Only 11 (65% of those receiving aciclovir had CSF herpes virus PCR. Seventeen had cranial imaging and it was the first management step in 14. Treatment lengths of both antibiotics and aciclovir were highly variable: one child with HSV encephalitis was only treated with aciclovir for 7 days. Conclusions The clinical management of children with suspected CNS infections across the Mersey region is heterogeneous and often sub-optimal, particularly for the investigation and treatment of viral encephalitis. National guidelines for the management of viral encephalitis are needed.

  14. Suboptimal T-cell receptor signaling compromises protein translation, ribosome biogenesis, and proliferation of mouse CD8 T cells.

    Science.gov (United States)

    Tan, Thomas C J; Knight, John; Sbarrato, Thomas; Dudek, Kate; Willis, Anne E; Zamoyska, Rose

    2017-07-25

    Global transcriptomic and proteomic analyses of T cells have been rich sources of unbiased data for understanding T-cell activation. Lack of full concordance of these datasets has illustrated that important facets of T-cell activation are controlled at the level of translation. We undertook translatome analysis of CD8 T-cell activation, combining polysome profiling and microarray analysis. We revealed that altering T-cell receptor stimulation influenced recruitment of mRNAs to heavy polysomes and translation of subsets of genes. A major pathway that was compromised, when TCR signaling was suboptimal, was linked to ribosome biogenesis, a rate-limiting factor in both cell growth and proliferation. Defective TCR signaling affected transcription and processing of ribosomal RNA precursors, as well as the translation of specific ribosomal proteins and translation factors. Mechanistically, IL-2 production was compromised in weakly stimulated T cells, affecting the abundance of Myc protein, a known regulator of ribosome biogenesis. Consequently, weakly activated T cells showed impaired production of ribosomes and a failure to maintain proliferative capacity after stimulation. We demonstrate that primary T cells respond to various environmental cues by regulating ribosome biogenesis and mRNA translation at multiple levels to sustain proliferation and differentiation.

  15. Awareness of radiation protection and dose levels of imaging procedures among medical students, radiography students, and radiology residents at an academic hospital: Results of a comprehensive survey

    International Nuclear Information System (INIS)

    Faggioni, Lorenzo; Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Caramella, Davide

    2017-01-01

    Highlights: • Medical students tend to overstate their knowledge of radiation protection (RP). • Overall RP knowledge of young doctors and students is suboptimal. • RP teaching to undergraduates and postgraduates needs to be substantially improved. - Abstract: Purpose: To evaluate the awareness of radiation protection issues and the knowledge of dose levels of imaging procedures among medical students, radiology residents, and radiography students at an academic hospital. Material and methods: A total of 159 young doctors and students (including 60 radiology residents, 56 medical students, and 43 radiography students) were issued a questionnaire consisting of 16 multiple choice questions divided into three separated sections (i.e., demographic data, awareness about radiation protection issues, and knowledge about radiation dose levels of common radiological examinations). Results: Medical students claimed to have at least a good knowledge of radiation protection issues more frequently than radiology residents and radiography students (94.4% vs 55% and 35.7%, respectively; P < 0.05), with no cases of perceived excellent knowledge among radiography students. However, the actual knowledge of essential radiation protection topics such as regulations, patient and tissue susceptibility to radiation damage, professional radiation risk and dose optimisation, as well as of radiation doses delivered by common radiological procedures was significantly worse among medical students than radiology residents and radiography students (P < 0.05). Those latter significantly outperformed radiology residents as to knowledge of radiation protection issues (P < 0.01). Overall, less than 50% of survey respondents correctly answered all questions of the survey. Conclusions: Radiology residents, radiography students and medical students have a limited awareness about radiation protection, with a specific gap of knowledge concerning real radiation doses of daily radiological

  16. Awareness of radiation protection and dose levels of imaging procedures among medical students, radiography students, and radiology residents at an academic hospital: Results of a comprehensive survey

    Energy Technology Data Exchange (ETDEWEB)

    Faggioni, Lorenzo, E-mail: lfaggioni@sirm.org [Department of Diagnostic and Interventional Radiology, University of Pisa, Via Roma 67, 56100, Pisa (Italy); Paolicchi, Fabio [Department of Diagnostic and Interventional Radiology, University of Pisa, Via Roma 67, 56100, Pisa (Italy); Bastiani, Luca [Institute of Clinical Physiology, National Research Council, Via Moruzzi 1, 56124, Pisa (Italy); Guido, Davide [Unit of Biostatistics and Clinical Epidemiology, Department of Public Health, Experimental and Forensic Medicine, University of Pavia, Via Forlanini 2, 27100, Pavia (Italy); Caramella, Davide [Department of Diagnostic and Interventional Radiology, University of Pisa, Via Roma 67, 56100, Pisa (Italy)

    2017-01-15

    Highlights: • Medical students tend to overstate their knowledge of radiation protection (RP). • Overall RP knowledge of young doctors and students is suboptimal. • RP teaching to undergraduates and postgraduates needs to be substantially improved. - Abstract: Purpose: To evaluate the awareness of radiation protection issues and the knowledge of dose levels of imaging procedures among medical students, radiology residents, and radiography students at an academic hospital. Material and methods: A total of 159 young doctors and students (including 60 radiology residents, 56 medical students, and 43 radiography students) were issued a questionnaire consisting of 16 multiple choice questions divided into three separated sections (i.e., demographic data, awareness about radiation protection issues, and knowledge about radiation dose levels of common radiological examinations). Results: Medical students claimed to have at least a good knowledge of radiation protection issues more frequently than radiology residents and radiography students (94.4% vs 55% and 35.7%, respectively; P < 0.05), with no cases of perceived excellent knowledge among radiography students. However, the actual knowledge of essential radiation protection topics such as regulations, patient and tissue susceptibility to radiation damage, professional radiation risk and dose optimisation, as well as of radiation doses delivered by common radiological procedures was significantly worse among medical students than radiology residents and radiography students (P < 0.05). Those latter significantly outperformed radiology residents as to knowledge of radiation protection issues (P < 0.01). Overall, less than 50% of survey respondents correctly answered all questions of the survey. Conclusions: Radiology residents, radiography students and medical students have a limited awareness about radiation protection, with a specific gap of knowledge concerning real radiation doses of daily radiological

  17. What is correct: equivalent dose or dose equivalent

    International Nuclear Information System (INIS)

    Franic, Z.

    1994-01-01

    In Croatian language some physical quantities in radiation protection dosimetry have not precise names. Consequently, in practice either terms in English or mathematical formulas are used. The situation is even worse since the Croatian language only a limited number of textbooks, reference books and other papers are available. This paper compares the concept of ''dose equivalent'' as outlined in International Commission on Radiological Protection (ICRP) recommendations No. 26 and newest, conceptually different concept of ''equivalent dose'' which is introduced in ICRP 60. It was found out that Croatian terminology is both not uniform and unprecise. For the term ''dose equivalent'' was, under influence of Russian and Serbian languages, often used as term ''equivalent dose'' even from the point of view of ICRP 26 recommendations, which was not justified. Unfortunately, even now, in Croatia the legal unit still ''dose equivalent'' defined as in ICRP 26, but the term used for it is ''equivalent dose''. Therefore, in Croatian legislation a modified set of quantities introduced in ICRP 60, should be incorporated as soon as possible

  18. Augmentation by escitalopram, but not citalopram or R-citalopram, of the effects of low-dose risperidone: behavioral, biochemical, and electrophysiological evidence.

    Science.gov (United States)

    Marcus, Monica M; Jardemark, Kent; Malmerfelt, Anna; Gertow, Jens; Konradsson-Geuken, Asa; Svensson, Torgny H

    2012-04-01

    Antidepressant drugs are frequently used to treat affective symptoms in schizophrenia. We have recently shown that escitalopram, but not citalopram or R-citalopram, increases firing rate and burst firing of midbrain dopamine neurons, potentiates cortical N-methyl-D-aspartate (NMDA) receptor-mediated transmission and enhances cognition, effects that might influence the outcome of concomitant antipsychotic medication. Here, we studied, in rats, the behavioral and neurobiological effects of adding escitalopram, citalopram, or R-citalopram to the second-generation antipsychotic drug risperidone. We examined antipsychotic efficacy using the conditioned avoidance response (CAR) test, extrapyramidal side effect (EPS) liability using a catalepsy test, dopamine outflow in the medial prefrontal cortex (mPFC) and nucleus accumbens using in vivo microdialysis in freely moving animals, and NMDA receptor-mediated transmission in the mPFC using intracellular electrophysiological recording in vitro. Only escitalopram (5 mg/kg), but not citalopram (10 mg/kg), or R-citalopram (10 mg/kg), dramatically enhanced the antipsychotic-like effect of a low dose of risperidone (0.25 mg/kg), without increasing catalepsy. Given alone, escitalopram, but not citalopram or R-citalopram, markedly enhanced both cortical dopamine output and NMDA receptor-mediated transmission. Addition of escitalopram and to some extent R-citalopram, but not citalopram, significantly enhanced both cortical dopamine output and cortical NMDA receptor-mediated transmission induced by a suboptimal dose/concentration of risperidone. These results suggest that adjunct treatment with escitalopram, but not citalopram, may enhance the effect of a subtherapeutic dose of risperidone on positive, negative, cognitive, and depressive symptoms in schizophrenia, yet without increased EPS liability. Copyright © 2011 Wiley Periodicals, Inc.

  19. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  20. The impact of a 600-mg loading dose of clopidogrel in diabetic and non-diabetic patients undergoing elective PCI.

    Science.gov (United States)

    Mohareb, Mina W; Abd Elghany, Mohamed; Sabry, Nirmeen A; Farid, Samar F

    2016-08-01

    High platelet reactivity (HPR) and suboptimal response to dual antiplatelet therapy (DAPT) may explain high recurrent rates of ischemic events in type 1 and 2 diabetes mellitus (DM) patients undergoing percutaneous coronary intervention (PCI). The aim of this study was to determine the effect of diabetes mellitus on clopidogrel activity in cardiac patients undergoing PCI. This is an observational study. Patients were categorized according to DM status into diabetic group (N.=30) and non-diabetic group (N.=33). All patients received clopidogrel in a loading dose of 600 mg before PCI. Platelet function was assessed using light transmittance aggregometry (LTA) technique at baseline (before clopidogrel administration), 24 hour after clopidogrel loading dose administration and 7-10 days after PCI. All patients were followed up for at least one year after PCI for recurrence of acute cardiac events. There was no statistically significant difference between the two groups with respect to 10 µm adenosine diphosphate (ADP)-induced platelet aggregation measured at baseline (P=0.64), 24 hours after PCI (P=0.874), and 7-10 days after PCI (0.643). Diabetics were not significantly different from non-diabetics in terms of post-PCI acute stent thrombosis (P=0.945), sub-acute stent thrombosis (P=0.945), unstable angina (P=0.29) and cardiac death (P=0.64). There was a statistically significant difference between patients with and without post-PCI acute events regarding ADP aggregation measured 24 hours and 7-10 days after PCI. The use of a high loading dose of clopidogrel (600 mg) in patients undergoing elective PCI can overcome the significant increase in post-PCI platelet aggregation and rate of acute cardiac events induced by diabetes mellitus as co-morbidity in those patients.

  1. A novel dose uncertainty model and its application for dose verification

    International Nuclear Information System (INIS)

    Jin Hosang; Chung Heetaek; Liu Chihray; Palta, Jatinder; Suh, Tae-Suk; Kim, Siyong

    2005-01-01

    Based on statistical approach, a novel dose uncertainty model was introduced considering both nonspatial and spatial dose deviations. Non-space-oriented uncertainty is mainly caused by dosimetric uncertainties, and space-oriented dose uncertainty is the uncertainty caused by all spatial displacements. Assuming these two parts are independent, dose difference between measurement and calculation is a linear combination of nonspatial and spatial dose uncertainties. Two assumptions were made: (1) the relative standard deviation of nonspatial dose uncertainty is inversely proportional to the dose standard deviation σ, and (2) the spatial dose uncertainty is proportional to the gradient of dose. The total dose uncertainty is a quadratic sum of the nonspatial and spatial uncertainties. The uncertainty model provides the tolerance dose bound for comparison between calculation and measurement. In the statistical uncertainty model based on a Gaussian distribution, a confidence level of 3σ theoretically confines 99.74% of measurements within the bound. By setting the confidence limit, the tolerance bound for dose comparison can be made analogous to that of existing dose comparison methods (e.g., a composite distribution analysis, a γ test, a χ evaluation, and a normalized agreement test method). However, the model considers the inherent dose uncertainty characteristics of the test points by taking into account the space-specific history of dose accumulation, while the previous methods apply a single tolerance criterion to the points, although dose uncertainty at each point is significantly different from others. Three types of one-dimensional test dose distributions (a single large field, a composite flat field made by two identical beams, and three-beam intensity-modulated fields) were made to verify the robustness of the model. For each test distribution, the dose bound predicted by the uncertainty model was compared with simulated measurements. The simulated

  2. A dose error evaluation study for 4D dose calculations

    Science.gov (United States)

    Milz, Stefan; Wilkens, Jan J.; Ullrich, Wolfgang

    2014-10-01

    Previous studies have shown that respiration induced motion is not negligible for Stereotactic Body Radiation Therapy. The intrafractional breathing induced motion influences the delivered dose distribution on the underlying patient geometry such as the lung or the abdomen. If a static geometry is used, a planning process for these indications does not represent the entire dynamic process. The quality of a full 4D dose calculation approach depends on the dose coordinate transformation process between deformable geometries. This article provides an evaluation study that introduces an advanced method to verify the quality of numerical dose transformation generated by four different algorithms. The used transformation metric value is based on the deviation of the dose mass histogram (DMH) and the mean dose throughout dose transformation. The study compares the results of four algorithms. In general, two elementary approaches are used: dose mapping and energy transformation. Dose interpolation (DIM) and an advanced concept, so called divergent dose mapping model (dDMM), are used for dose mapping. The algorithms are compared to the basic energy transformation model (bETM) and the energy mass congruent mapping (EMCM). For evaluation 900 small sample regions of interest (ROI) are generated inside an exemplary lung geometry (4DCT). A homogeneous fluence distribution is assumed for dose calculation inside the ROIs. The dose transformations are performed with the four different algorithms. The study investigates the DMH-metric and the mean dose metric for different scenarios (voxel sizes: 8 mm, 4 mm, 2 mm, 1 mm 9 different breathing phases). dDMM achieves the best transformation accuracy in all measured test cases with 3-5% lower errors than the other models. The results of dDMM are reasonable and most efficient in this study, although the model is simple and easy to implement. The EMCM model also achieved suitable results, but the approach requires a more complex

  3. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  4. Biological influence from low dose and low-dose rate radiation

    International Nuclear Information System (INIS)

    Magae, Junji

    2007-01-01

    Although living organisms have defense mechanisms for radioadaptive response, the influence is considered to vary qualitatively and quantitatively for low dose and high dose, as well as for low-dose rate and high-dose rate. This article describes the bioresponse to low dose and low-dose rate. Among various biomolecules, DNA is the most sensitive to radiation, and accurate replication of DNA is an essential requirement for the survival of living organisms. Also, the influence of active enzymes resulted from the effect of radiation on enzymes in the body is larger than the direct influence of radiation on the body. After this, the article describes the carcinogenic risk by low-dose radiation, and then so-called Hormesis effect to create cancer inhibition effect by stimulating active physiology. (S.K.)

  5. Superficial dose evaluation of four dose calculation algorithms

    Science.gov (United States)

    Cao, Ying; Yang, Xiaoyu; Yang, Zhen; Qiu, Xiaoping; Lv, Zhiping; Lei, Mingjun; Liu, Gui; Zhang, Zijian; Hu, Yongmei

    2017-08-01

    Accurate superficial dose calculation is of major importance because of the skin toxicity in radiotherapy, especially within the initial 2 mm depth being considered more clinically relevant. The aim of this study is to evaluate superficial dose calculation accuracy of four commonly used algorithms in commercially available treatment planning systems (TPS) by Monte Carlo (MC) simulation and film measurements. The superficial dose in a simple geometrical phantom with size of 30 cm×30 cm×30 cm was calculated by PBC (Pencil Beam Convolution), AAA (Analytical Anisotropic Algorithm), AXB (Acuros XB) in Eclipse system and CCC (Collapsed Cone Convolution) in Raystation system under the conditions of source to surface distance (SSD) of 100 cm and field size (FS) of 10×10 cm2. EGSnrc (BEAMnrc/DOSXYZnrc) program was performed to simulate the central axis dose distribution of Varian Trilogy accelerator, combined with measurements of superficial dose distribution by an extrapolation method of multilayer radiochromic films, to estimate the dose calculation accuracy of four algorithms in the superficial region which was recommended in detail by the ICRU (International Commission on Radiation Units and Measurement) and the ICRP (International Commission on Radiological Protection). In superficial region, good agreement was achieved between MC simulation and film extrapolation method, with the mean differences less than 1%, 2% and 5% for 0°, 30° and 60°, respectively. The relative skin dose errors were 0.84%, 1.88% and 3.90%; the mean dose discrepancies (0°, 30° and 60°) between each of four algorithms and MC simulation were (2.41±1.55%, 3.11±2.40%, and 1.53±1.05%), (3.09±3.00%, 3.10±3.01%, and 3.77±3.59%), (3.16±1.50%, 8.70±2.84%, and 18.20±4.10%) and (14.45±4.66%, 10.74±4.54%, and 3.34±3.26%) for AXB, CCC, AAA and PBC respectively. Monte Carlo simulation verified the feasibility of the superficial dose measurements by multilayer Gafchromic films. And the rank

  6. Low-dose oxytocin delivered intranasally with Breath Powered device affects social-cognitive behavior: a randomized four-way crossover trial with nasal cavity dimension assessment.

    Science.gov (United States)

    Quintana, D S; Westlye, L T; Rustan, Ø G; Tesli, N; Poppy, C L; Smevik, H; Tesli, M; Røine, M; Mahmoud, R A; Smerud, K T; Djupesland, P G; Andreassen, O A

    2015-07-14

    Despite the promise of intranasal oxytocin (OT) for modulating social behavior, recent work has provided mixed results. This may relate to suboptimal drug deposition achieved with conventional nasal sprays, inter-individual differences in nasal physiology and a poor understanding of how intranasal OT is delivered to the brain in humans. Delivering OT using a novel 'Breath Powered' nasal device previously shown to enhance deposition in intranasal sites targeted for nose-to-brain transport, we evaluated dose-dependent effects on social cognition, compared response with intravenous (IV) administration of OT, and assessed nasal cavity dimensions using acoustic rhinometry. We adopted a randomized, double-blind, double-dummy, crossover design, with 16 healthy male adults completing four single-dose treatments (intranasal 8 IU (international units) or 24 IU OT, 1 IU OT IV and placebo). The primary outcome was social cognition measured by emotional ratings of facial images. Secondary outcomes included the pharmacokinetics of OT, vasopressin and cortisol in blood and the association between nasal cavity dimensions and emotional ratings. Despite the fact that all the treatments produced similar plasma OT increases compared with placebo, there was a main effect of treatment on anger ratings of emotionally ambiguous faces. Pairwise comparisons revealed decreased ratings after 8 IU OT in comparison to both placebo and 24 IU OT. In addition, there was an inverse relationship between nasal valve dimensions and anger ratings of ambiguous faces after 8-IU OT treatment. These findings provide support for a direct nose-to-brain effect, independent of blood absorption, of low-dose OT delivered from a Breath Powered device.

  7. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  8. Fast in vivo volume dose reconstruction via reference dose perturbation

    International Nuclear Information System (INIS)

    Lu, Weiguo; Chen, Mingli; Mo, Xiaohu; Parnell, Donald; Olivera, Gustavo; Galmarini, Daniel

    2014-01-01

    Purpose: Accurate on-line reconstruction of in-vivo volume dose that accounts for both machine and patient discrepancy is not clinically available. We present a simple reference-dose-perturbation algorithm that reconstructs in-vivo volume dose fast and accurately. Methods: We modelled the volume dose as a function of the fluence map and density image. Machine (output variation, jaw/leaf position errors, etc.) and patient (setup error, weight loss, etc.) discrepancies between the plan and delivery were modelled as perturbation of the fluence map and density image, respectively. Delivered dose is modelled as perturbation of the reference dose due to change of the fluence map and density image. We used both simulated and clinical data to validate the algorithm. The planned dose was used as the reference. The reconstruction was perturbed from the reference and accounted for output-variations and the registered daily image. The reconstruction was compared with the ground truth via isodose lines and the Gamma Index. Results: For various plans and geometries, the volume doses were reconstructed in few seconds. The reconstruction generally matched well with the ground truth. For the 3%/3mm criteria, the Gamma pass rates were 98% for simulations and 95% for clinical data. The differences mainly appeared on the surface of the phantom/patient. Conclusions: A novel reference-dose-perturbation dose reconstruction model is presented. The model accounts for machine and patient discrepancy from planning. The algorithm is simple, fast, yet accurate, which makes online in-vivo 3D dose reconstruction clinically feasible.

  9. Estimation of the transit dose component in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Garcia Romero, A.; Millan Cebrian, E.; Lozano Flores, F.J.; Lope Lope, R.; Canellas Anoz, M.

    2001-01-01

    Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author) [es

  10. Effective dose and dose to crystalline lens during angiographic procedures

    International Nuclear Information System (INIS)

    Pages, J.

    1998-01-01

    The highest radiation doses levels received by radiologists are observed during interventional procedures. Doses to forehead and neck received by a radiologist executing angiographic examinations at the department of radiology at the academic hospital (AZ-VUB) have been measured for a group of 34 examinations. The doses to crystalline lens and the effective doses for a period of one year have been estimated. For the crystalline lens the maximum dose approaches the ICRP limit, that indicates the necessity for the radiologist to use leaded glasses. (N.C.)

  11. Accelerated partial breast irradiation: An analysis of variables associated with late toxicity and long-term cosmetic outcome after high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Wazer, David E.; Kaufman, Seth; Cuttino, Laurie; Di Petrillo, Thomas; Arthur, Douglas W.

    2006-01-01

    . Suboptimal cosmetic outcome was significantly associated with the number of source dwell positions, V150, and V200 and inversely associated with DHI (0.77 vs. 0.73; p = 0.05). Late skin toxicity was rated as Grade 0, 1, or 2 in 77%, 19%, and 4% of patients, respectively. The risk of Grade 1/2 skin toxicity was significantly associated with V150 and V200 and inversely associated with DHI (0.77 vs. 0.71; p = 0.009). Late subcutaneous toxicity was rated as Grade 0, 1, 2, 3, or 4 in 55%, 15%, 12%, 5%, and 13% of patients, respectively. The risk of Grade 0/1 vs. Grade 2-4 subcutaneous toxicity was significantly associated only with a lower value of DHI (0.77 vs. 0.73; p = 0.02). To further explore factors that might contribute to the risk of fat necrosis (symptomatic or asymptomatic), a separate analysis showed that only dose hotspots as reflected in V150 and V200 were significantly associated with elevated risk. The use of adriamycin-based chemotherapy after APBI was found to be associated with a significant increase in the incidence of higher-grade skin toxicity and a higher risk of fat necrosis and suboptimal cosmetic outcome. Patient age, volume of resection, extent of axillary surgery, a history of diabetes or hypertension, and the use of tamoxifen were not found to be significantly associated with cosmetic outcome or late normal tissue complications. Conclusions: Long-term cosmetic results and the risk of late skin and subcutaneous toxicity after APBI with interstitial HDR brachytherapy can be correlated with specific treatment-related variables. These data provide dosimetric parameters that might be used to minimize the risk of normal tissue injury after APBI interstitial brachytherapy

  12. Prescribing and evaluating target dose in dose-painting treatment plans

    DEFF Research Database (Denmark)

    Håkansson, Katrin; Specht, Lena; Aznar, Marianne C

    2014-01-01

    BACKGROUND: Assessment of target dose conformity in multi-dose-level treatment plans is challenging due to inevitable over/underdosage at the border zone between dose levels. Here, we evaluate different target dose prescription planning aims and approaches to evaluate the relative merit of such p......-painting and multi-dose-level plans. The tool can be useful for quality assurance of multi-center trials, and for visualizing the development of treatment planning in routine clinical practice....... of such plans. A quality volume histogram (QVH) tool for history-based evaluation is proposed. MATERIAL AND METHODS: Twenty head and neck cancer dose-painting plans with five prescription levels were evaluated, as well as clinically delivered simultaneous integrated boost (SIB) plans from 2010 and 2012. The QVH...

  13. Suboptimal protection against H5N1 highly pathogenic avian influenza viruses from Vietnam in ducks vaccinated with commercial poultry vaccines.

    Science.gov (United States)

    Cha, Ra Mi; Smith, Diane; Shepherd, Eric; Davis, C Todd; Donis, Ruben; Nguyen, Tung; Nguyen, Hoang Dang; Do, Hoa Thi; Inui, Ken; Suarez, David L; Swayne, David E; Pantin-Jackwood, Mary

    2013-10-09

    Domestic ducks are the second most abundant poultry species in many Asian countries including Vietnam, and play a critical role in the epizootiology of H5N1 highly pathogenic avian influenza (HPAI) [FAO]. In this study, we examined the protective efficacy in ducks of two commercial H5N1 vaccines widely used in Vietnam; Re-1 containing A/goose/Guangdong/1/1996 hemagglutinin (HA) clade 0 antigens, and Re-5 containing A/duck/Anhui/1/2006 HA clade 2.3.4 antigens. Ducks received two doses of either vaccine at 7 and at 14 or 21 days of age followed by challenge at 30 days of age with viruses belonging to the HA clades 1.1, 2.3.4.3, 2.3.2.1.A and 2.3.2.1.B isolated between 2008 and 2011 in Vietnam. Ducks vaccinated with the Re-1 vaccine were protected after infection with the two H5N1 HPAI viruses isolated in 2008 (HA clades 1.1 and 2.3.4.3) showing no mortality and limited virus shedding. The Re-1 and Re-5 vaccines conferred 90-100% protection against mortality after challenge with the 2010 H5N1 HPAI viruses (HA clade 2.3.2.1.A); but vaccinated ducks shed virus for more than 7 days after challenge. Similarly, the Re-1 and Re-5 vaccines only showed partial protection against the 2011 H5N1 HPAI viruses (HA clade 2.3.2.1.A and 2.3.2.1.B), with a high proportion of vaccinated ducks shedding virus for more than 10 days. Furthermore, 50% mortality was observed in ducks vaccinated with Re-1 and challenged with the 2.3.2.1.B virus. The HA proteins of the 2011 challenge viruses had the greatest number of amino acid differences from the two vaccines as compared to the viruses from 2008 and 2009, which correlates with the lesser protection observed with these viruses. These studies demonstrate the suboptimal protection conferred by the Re-1 and Re-5 commercial vaccines in ducks against H5N1 HPAI clade 2.3.2.1 viruses, and underscore the importance of monitoring vaccine efficacy in the control of H5N1 HPAI in ducks. Published by Elsevier Ltd.

  14. DETERMINANTS OF SUBOPTIMAL BLOOD PRESSURE CONTROL IN HYPERTENSIVE PATIENTS: 24-HOUR AMBULATORY BLOOD PRES-SURE MONITORING

    Directory of Open Access Journals (Sweden)

    Mansoor Moazenzadeh

    2010-12-01

    Full Text Available Abstract    INTRODUCTION: The study was conducted to define the determinants of suboptimal blood pressure (BP control among hypertensive patients under treatment and explore a predictive model for detecting the patients at risk for increased BP.    METHODS: We enrolled 97 patients (40 males, 57 females under treatment for hypertension between June 2006 and May 2007 in Shafa hospital, Kerman, Iran. BP was measured at clinic twice within 5-minute intervals. After setting up ambulatory blood pressure monitoring (ABPM, BP was measured at 30-minute intervals during the day and 60-minute intervals during the night. The frequency of increased BP (more than 140/90 mmHg was included in a regression model as dependent variable and all the others such as age, sex, body mass index (BMI, drugs and baseline clinical measurements as the predictors.    RESULTS: Increased BP was detected in 44% (95% CI: 38.79%-49.65% of all measurements during 24-hour monitoring. The frequency of increased BP had a significant relationship with BMI (b=0.35, P=0.001. Clinic's pulse pressure was a significant predicting factor for BP increase (P=0.02.    CONCLUSION: BMI and pulse pressure are the best predictors for being hypertensive during lifetime. Ineffective treatment of hypertension is frequent among the hypertensive patients.      Keywords: Blood pressure control, Pulse pressure, Ambulatory blood pressure monitoring (ABPM, BMI.

  15. Suboptimal HIV Testing Uptake Among Men Who Engage in Commercial Sex Work with Men in Asia.

    Science.gov (United States)

    Jin, Harry; Friedman, Mackey Reuel; Lim, Sin How; Guadamuz, Thomas E; Wei, Chongyi

    2016-12-01

    Men who have sex with men and are sex workers (MSMSW) are disproportionately affected by the growing and emerging HIV epidemic. As sex work and same-sex behavior are heavily stigmatized and often illegal in most Asian countries, HIV research focusing on MSMSW has been limited. The goal of this analysis is to examine HIV testing practices and identify correlates of HIV testing among MSMSW in Asia. The Asia Internet MSM Sex Survey, an online cross-sectional survey of 10,861 men who have sex with men (MSM), was conducted in 2010. Data on sociodemographic characteristics, HIV testing behaviors, and sexual behaviors were collected. Five hundred and seventy-four HIV-negative/unknown respondents reported receiving payment for sex with men at least once in the past 6 months and were included in this analysis. Multivariable logistic regression was conducted to identify independent correlates of HIV testing in the past year. About half (48.6%) of the participants had been tested for HIV at least once within the past year, and 30.5% had never been tested. We also found that MSMSW participants who engaged in risky behaviors were less likely to be tested. While one might expect a high HIV testing rate among MSMSW due to the risks associated with engaging in sex work, we found that HIV testing uptake is suboptimal among MSMSW in Asia. These results suggest that targeted HIV prevention and testing promotion among MSMSW are needed.

  16. Isobio software: biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model.

    Science.gov (United States)

    Jaikuna, Tanwiwat; Khadsiri, Phatchareewan; Chawapun, Nisa; Saekho, Suwit; Tharavichitkul, Ekkasit

    2017-02-01

    To develop an in-house software program that is able to calculate and generate the biological dose distribution and biological dose volume histogram by physical dose conversion using the linear-quadratic-linear (LQL) model. The Isobio software was developed using MATLAB version 2014b to calculate and generate the biological dose distribution and biological dose volume histograms. The physical dose from each voxel in treatment planning was extracted through Computational Environment for Radiotherapy Research (CERR), and the accuracy was verified by the differentiation between the dose volume histogram from CERR and the treatment planning system. An equivalent dose in 2 Gy fraction (EQD 2 ) was calculated using biological effective dose (BED) based on the LQL model. The software calculation and the manual calculation were compared for EQD 2 verification with pair t -test statistical analysis using IBM SPSS Statistics version 22 (64-bit). Two and three-dimensional biological dose distribution and biological dose volume histogram were displayed correctly by the Isobio software. Different physical doses were found between CERR and treatment planning system (TPS) in Oncentra, with 3.33% in high-risk clinical target volume (HR-CTV) determined by D 90% , 0.56% in the bladder, 1.74% in the rectum when determined by D 2cc , and less than 1% in Pinnacle. The difference in the EQD 2 between the software calculation and the manual calculation was not significantly different with 0.00% at p -values 0.820, 0.095, and 0.593 for external beam radiation therapy (EBRT) and 0.240, 0.320, and 0.849 for brachytherapy (BT) in HR-CTV, bladder, and rectum, respectively. The Isobio software is a feasible tool to generate the biological dose distribution and biological dose volume histogram for treatment plan evaluation in both EBRT and BT.

  17. Applications of sub-optimality in dynamic programming to location and construction of nuclear fuel processing plant; Application de la sous-optimalite en programmation dynamique a la localisation et la cadence optimales de construction des equipements

    Energy Technology Data Exchange (ETDEWEB)

    Thiriet, L; Deledicq, A [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires, section des etudes economiques generales

    1968-09-01

    First, the point of applying Dynamic Programming to optimization and Operational Research problems in chemical industries are recalled, as well as the conditions in which a dynamic program is illustrated by a sequential graph. A new algorithm for the determination of sub-optimal politics in a sequential graph is then developed. Finally, the applications of sub-optimality concept is shown when taking into account the indirect effects related to possible strategies, or in the case of stochastic choices and of problems of the siting of plants... application examples are given. (authors) [French] On rappelle d'abord l'interet de la Programmation Dynamique dans les problemes d'optimisation et de Recherche Operationnelle dans les industries chimiques, et les conditions de representation d'un programme dynamique par un graphe sequentiel. On expose ensuite un nouvel algorithme de determination de politiques sous-optimales dans un graphe sequentiel. On montre enfin les applications du concept de sous-optimalite a la prise en compte d'effets indirects lies aux politiques possibles, aux choix dans l'aleatoire, a des problemes de localisation optimale d'usines... et on donne des exemples d'utilisation. (auteurs)

  18. Effects of mannan oligosaccharide and virginiamycin on the cecal microbial community and intestinal morphology of chickens raised under suboptimal conditions.

    Science.gov (United States)

    Pourabedin, Mohsen; Xu, Zhengxin; Baurhoo, Bushansingh; Chevaux, Eric; Zhao, Xin

    2014-05-01

    There is an increasing movement against use of antibiotic growth promoters in animal feed. Prebiotic supplementation is a potential alternative to enhance the host's natural defense through modulation of gut microbiota. In the present study, the effect of mannan oligosaccharide (MOS) and virginiamycin (VIRG) on cecal microbial ecology and intestinal morphology of broiler chickens raised under suboptimal conditions was evaluated. MOS and VIRG induced different bacterial community structures, as revealed by denaturing gradient gel electrophoresis of 16S rDNA. The antibiotic treatment reduced cecal microbial diversity while the community equitability increased. A higher bacterial diversity was observed in the cecum of MOS-supplemented birds. Quantitative polymerase chain reaction results indicated that MOS changed the cecal microbiota in favor of the Firmicutes population but not the Bacteroidetes population. No difference was observed in total bacterial counts among treatments. MOS promoted the growth of Lactobacillus spp. and Bifidobacterium spp. in the cecum and increased villus height and goblet cell numbers in the ileum and jejunum. These results provide a deeper insight into the microbial ecological changes after supplementation of MOS prebiotic in poultry diets.

  19. Patient dose measurement and dose reduction in chest radiography

    Directory of Open Access Journals (Sweden)

    Milatović Aleksandra A.

    2014-01-01

    Full Text Available Investigations presented in this paper represent the first estimation of patient doses in chest radiography in Montenegro. In the initial stage of our study, we measured the entrance surface air kerma and kerma area product for chest radiography in five major health institutions in the country. A total of 214 patients were observed. We reported the mean value, minimum and third quartile values, as well as maximum values of surface air kerma and kerma area product of patient doses. In the second stage, the possibilities for dose reduction were investigated. Mean kerma area product values were 0.8 ± 0.5 Gycm2 for the posterior-anterior projection and 1.6 ± 0.9 Gycm2 for the lateral projection. The max/min ratio for the entrance surface air kerma was found to be 53 for the posterior-anterior projection and 88 for the lateral projection. Comparing the results obtained in Montenegro with results from other countries, we concluded that patient doses in our medical centres are significantly higher. Changes in exposure parameters and increased filtration contributed to a dose reduction of up to 36% for posterior-anterior chest examinations. The variability of the estimated dose values points to a significant space for dose reduction throughout the process of radiological practice optimisation.

  20. Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Expósito, M., E-mail: mariateresa.romero@uab.cat; Domingo, C.; Ortega-Gelabert, O.; Gallego, S. [Grup de Recerca en Radiacions Ionizants (GRRI), Departament de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Sánchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009 (Spain); Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41009 (Spain)

    2016-01-15

    Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose

  1. Health effect of low dose/low dose rate radiation

    International Nuclear Information System (INIS)

    Kodama, Seiji

    2012-01-01

    The clarified and non-clarified scientific knowledge is discussed to consider the cause of confusion of explanation of the title subject. The low dose is defined roughly lower than 200 mGy and low dose rate, 0.05 mGy/min. The health effect is evaluated from 2 aspects of clinical symptom/radiation hazard protection. In the clinical aspect, the effect is classified in physical (early and late) and genetic ones, and is classified in stochastic (no threshold value, TV) and deterministic (with TV) ones from the radioprotection aspect. Although the absence of TV in the carcinogenic and genetic effects has not been proved, ICRP employs the stochastic standpoint from the safety aspect for radioprotection. The lowest human TV known now is 100 mGy, meaning that human deterministic effect would not be generated below this dose. Genetic deterministic effect can be observable only in animal experiments. These facts suggest that the practical risk of exposure to <100 mGy in human is the carcinogenesis. The relationship between carcinogenic risk in A-bomb survivors and their exposed dose are found fitted to the linear no TV model, but the epidemiologic data, because of restriction of subject number analyzed, do not always mean that the model is applicable even below the dose <100 mGy. This would be one of confusing causes in explanation: no carcinogenic risk at <100 mGy or risk linear to dose even at <100 mGy, neither of which is scientifically conclusive at present. Also mentioned is the scarce risk of cancer in residents living in the high background radiation regions in the world in comparison with that in the A-bomb survivors exposed to the chronic or acute low dose/dose rate. Molecular events are explained for the low-dose radiation-induced DNA damage and its repair, gene mutation and chromosome aberration, hypothesis of carcinogenesis by mutation, and non-targeting effect of radiation (bystander effect and gene instability). Further researches to elucidate the low dose

  2. Analysis of Cumulative Dose to Implanted Pacemaker According to Various IMRT Delivery Methods: Optimal Dose Delivery Versus Dose Reduction Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Woo; Hong, Se Mie [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of)

    2011-11-15

    Cancer patients with implanted cardiac pacemaker occasionally require radiotherapy. Pacemaker may be damaged or malfunction during radiotherapy due to ionizing radiation or electromagnetic interference. Although radiotherapy should be planned to keep the dose to pacemaker as low as possible not to malfunction ideally, current radiation treatment planning (RTP) system does not accurately calculate deposited dose to adjacent field border or area beyond irradiated fields. In terms of beam delivery techniques using multiple intensity modulated fields, dosimetric effect of scattered radiation in high energy photon beams is required to be detailed analyzed based on measurement data. The aim of this study is to evaluate dose discrepancies of pacemaker in a RTP system as compared to measured doses. We also designed dose reduction strategy limited value of 2 Gy for radiation treatment patients with cardiac implanted pacemaker. Total accumulated dose of 145 cGy based on in-vivo dosimetry was satisfied with the recommendation criteria to prevent malfunction of pacemaker in SS technique. However, the 2 mm lead shielder enabled the scattered doses to reduce up to 60% and 40% in the patient and the phantom, respectively. The SS technique with the lead shielding could reduce the accumulated scattered doses less than 100 cGy. Calculated and measured doses were not greatly affected by the beam delivery techniques. In-vivo and measured doses on pacemaker position showed critical dose discrepancies reaching up to 4 times as compared to planned doses in RTP. The current SS technique could deliver lower scattered doses than recommendation criteria, but use of 2 mm lead shielder contributed to reduce scattered doses by 60%. The tertiary lead shielder can be useful to prevent malfunction or electrical damage of implanted pacemakers during radiotherapy. It is required to estimate more accurate scattered doses of the patient or medical device in RTP to design proper dose reduction strategy.

  3. Analysis of Cumulative Dose to Implanted Pacemaker According to Various IMRT Delivery Methods: Optimal Dose Delivery Versus Dose Reduction Strategy

    International Nuclear Information System (INIS)

    Lee, Jeong Woo; Hong, Se Mie

    2011-01-01

    Cancer patients with implanted cardiac pacemaker occasionally require radiotherapy. Pacemaker may be damaged or malfunction during radiotherapy due to ionizing radiation or electromagnetic interference. Although radiotherapy should be planned to keep the dose to pacemaker as low as possible not to malfunction ideally, current radiation treatment planning (RTP) system does not accurately calculate deposited dose to adjacent field border or area beyond irradiated fields. In terms of beam delivery techniques using multiple intensity modulated fields, dosimetric effect of scattered radiation in high energy photon beams is required to be detailed analyzed based on measurement data. The aim of this study is to evaluate dose discrepancies of pacemaker in a RTP system as compared to measured doses. We also designed dose reduction strategy limited value of 2 Gy for radiation treatment patients with cardiac implanted pacemaker. Total accumulated dose of 145 cGy based on in-vivo dosimetry was satisfied with the recommendation criteria to prevent malfunction of pacemaker in SS technique. However, the 2 mm lead shielder enabled the scattered doses to reduce up to 60% and 40% in the patient and the phantom, respectively. The SS technique with the lead shielding could reduce the accumulated scattered doses less than 100 cGy. Calculated and measured doses were not greatly affected by the beam delivery techniques. In-vivo and measured doses on pacemaker position showed critical dose discrepancies reaching up to 4 times as compared to planned doses in RTP. The current SS technique could deliver lower scattered doses than recommendation criteria, but use of 2 mm lead shielder contributed to reduce scattered doses by 60%. The tertiary lead shielder can be useful to prevent malfunction or electrical damage of implanted pacemakers during radiotherapy. It is required to estimate more accurate scattered doses of the patient or medical device in RTP to design proper dose reduction strategy.

  4. Dose-reduction techniques for high-dose worker groups in nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.; Dionne, B.J.

    1991-03-01

    This report summarizes the main findings of a study of the extent of radiation dose received by special work groups in the nuclear power industry. Work groups which chronically get large doses were investigated, using information provided by the industry. The tasks that give high doses to these work groups were examined and techniques described that were found to be particularly successful in reducing dose. Quantitative information on the extent of radiation doses to various work groups shows that significant numbers of workers in several critical groups receive doses greater than 1 and even 2 rem per year, particularly contract personnel and workers at BWR-type plants. The number of radiation workers whose lifetime dose is greater than their age is much less. Although the techniques presented would go some way in reducing dose, it is likely that a sizeable reduction to the high-dose work groups may require development of new dose-reduction techniques as well as major changes in procedures. 10 refs., 26 tabs

  5. Analysis of workers' dose records from the Greek Dose Registry Information System

    International Nuclear Information System (INIS)

    Kamenopoulou, V.; Dimitriou, P.; Proukakis, Ch.

    1995-01-01

    The object of this work is the study of the individual film badge annual dose information of classified workers in Greece, monitored and assessed by the central dosimetry service of the Greek Atomic Energy Commission. Dose summaries were recorded and processed by the Dose Registry Information System. The statistical analysis refers to the years 1989-93 and deals with the distribution of individuals in the occupational groups, the mean annual dose, the collective dose, the distribution of the dose over the different specialties and the number of workers that have exceeded any of the established dose limits. Results concerning the annual dose summaries, demonstrate a year-by-year reduction in the mean individual dose to workers in the health sector. Conversely, exposures in the industrial sector did not show any decreasing tendency during the period under consideration. (Author)

  6. Dose from radiological examinations

    International Nuclear Information System (INIS)

    Imamura, Keiko; Uji, Teruyuki; Sakuyama, Keiko; Fujikawa, Mitsuhiro; Fujii, Masamichi

    1976-01-01

    Relatively high gonad doses, several hundred to one thousand mR, have been observed in case of pelvis, hip-joint, coccyx, lower abdomen and lumber examination. Dose to the ovary is especially high in barium enema and I.V.P. examinations. About 12 per cent of the 4-ray examination are high-dose. The gonad dose is relatively high in examination of abdomen and lower extremities, in infants. The dose to the eyes is especially high, 1.0 to 2.5R per exposure, in temporal bone and nasal sinuses tomography. X-ray doses have been compared with dose limits recommended by ICRP and with the gonad dose from natural radiations. The gonad dose in lumbar examination, barium enema, I.V.P. etc. is as high as the maximum permissible dose per year recommended by ICRP. Several devices have been made for dose reduction in the daily examinations: (1) separating the radiation field from the gonad by one centimeter decreases the gonad dose about one-half. (2) using sensitive screens and films. In pelvimetry and in infant hip-joint examination, the most sensitive screen and film are used. In the I.V.P. examination of adult, use of MS screen in place of FS screen decreases the dose to one-third, in combination with careful setting of radiation field, (3) use of grid increases the dose about 50 percent and the lead rubber protection (0.1mm lead equivalent) decreases the gonad dose to one-thirtieth in the spinal column examination of infant, (4) A lead protector, 1mm thickness and 2.5cm in diameter, on the eyes decreases the dose to about one-eighth in the face and nead examinations. These simple and effective methods for dose reduction. Should be carried out in as many examinations as possible in addition to observing dose limits recommended by ICRP. (Evans, J.)

  7. Dose conversion factors

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1992-01-01

    The following is discussed in this report: concepts and quantities used in calculating radiation dose from internal and external exposure. Tabulations of dose conversion factor for internal and external exposure to radionuclides. Dose conversion factors give dose per unit intake (internal) or dose per unit concentration in environment (external). Intakes of radionuclides for internal exposure and concentrations of radionuclides in environment for external exposure are assumed to be known. Intakes and concentrations are obtained, e.g., from analyses of environmental transport and exposure pathways. differences between dosimetry methods for radionuclides and hazardous chemicals are highlighted

  8. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    International Nuclear Information System (INIS)

    Abdollahi, Hamid; Shiri, Isaac; Salimi, Yazdan; Sarebani, Maghsoud; Mehdinia, Reza; Deevband, Mohammad Reza; Mahdavi, Seied Rabi; Sohrabi, Ahmad; Bitarafan-Rajabi, Ahmad

    2016-01-01

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  9. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Abdollahi, Hamid, E-mail: Hamid_rbp@yahoo.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Shiri, Isaac [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Salimi, Yazdan [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sarebani, Maghsoud; Mehdinia, Reza [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Deevband, Mohammad Reza [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Mahdavi, Seied Rabi [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Radiation Biology Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sohrabi, Ahmad [Department of Biostatistics, School of Public Health, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Bitarafan-Rajabi, Ahmad, E-mail: bitarafan@hotmail.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Department of Nuclear Medicine, Rajaei Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2016-12-15

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  10. On dose distribution comparison

    International Nuclear Information System (INIS)

    Jiang, Steve B; Sharp, Greg C; Neicu, Toni; Berbeco, Ross I; Flampouri, Stella; Bortfeld, Thomas

    2006-01-01

    In radiotherapy practice, one often needs to compare two dose distributions. Especially with the wide clinical implementation of intensity-modulated radiation therapy, software tools for quantitative dose (or fluence) distribution comparison are required for patient-specific quality assurance. Dose distribution comparison is not a trivial task since it has to be performed in both dose and spatial domains in order to be clinically relevant. Each of the existing comparison methods has its own strengths and weaknesses and there is room for improvement. In this work, we developed a general framework for comparing dose distributions. Using a new concept called maximum allowed dose difference (MADD), the comparison in both dose and spatial domains can be performed entirely in the dose domain. Formulae for calculating MADD values for various comparison methods, such as composite analysis and gamma index, have been derived. For convenience in clinical practice, a new measure called normalized dose difference (NDD) has also been proposed, which is the dose difference at a point scaled by the ratio of MADD to the predetermined dose acceptance tolerance. Unlike the simple dose difference test, NDD works in both low and high dose gradient regions because it considers both dose and spatial acceptance tolerances through MADD. The new method has been applied to a test case and a clinical example. It was found that the new method combines the merits of the existing methods (accurate, simple, clinically intuitive and insensitive to dose grid size) and can easily be implemented into any dose/intensity comparison tool

  11. Cancer risk of low dose/low dose rate radiation: a meta-analysis of cancer data of mammals exposed to low doses of radiation

    International Nuclear Information System (INIS)

    Ogata, Hiromitsu; Magae, Junji

    2008-01-01

    Full text: Linear No Threshold (LNT) model is a basic theory for radioprotection, but the adaptability of this hypothesis to biological responses at low doses or at low dose rates is not sufficiently investigated. Simultaneous consideration of the cumulative dose and the dose rate is necessary for evaluating the risk of long-term exposure to ionizing radiation at low dose. This study intends to examine several numerical relationships between doses and dose rates in biological responses to gamma radiation. Collected datasets on the relationship between dose and the incidence of cancer in mammals exposed to low doses of radiation were analysed using meta-regression models and modified exponential (MOE) model, which we previously published, that predicts irradiation time-dependent biological response at low dose rate ionizing radiation. Minimum doses of observable risk and effective doses with a variety of dose rates were calculated using parameters estimated by fitting meta-regression models to the data and compared them with other statistical models that find values corresponding to 'threshold limits'. By fitting a weighted regression model (fixed-effects meta-regression model) to the data on risk of all cancers, it was found that the log relative risk [log(RR)] increased as the total exposure dose increased. The intersection of this regression line with the x-axis denotes the minimum dose of observable risk. These estimated minimum doses and effective doses increased with decrease of dose rate. The goodness of fits of MOE-model depended on cancer types, but the total cancer risk is reduced when dose rates are very low. The results suggest that dose response curve for cancer risk is remarkably affected by dose rate and that dose rate effect changes as a function of dose rate. For scientific discussion on the low dose exposure risk and its uncertainty, the term 'threshold' should be statistically defined, and dose rate effects should be included in the risk

  12. Repaglinide/metformin fixed-dose combination to improve glycemic control in patients with type 2 diabetes: an update

    Directory of Open Access Journals (Sweden)

    Robert G Moses

    2010-05-01

    Full Text Available Robert G MosesClinical Trials and Research Unit, South East Sydney and Illawarra Area Health Service, New South Wales, AustraliaAbstract: Type 2 diabetes is a progressive disease associated with high levels of morbidity and mortality and for which there is both a large and growing prevalence worldwide. Lifestyle advice plus metformin is commonly recommended initially to manage hyperglycemia and to minimize the risk of vascular complications. However, additional agents are required when glycemic targets cannot be achieved or maintained due to the progressive nature of the disease. Repaglinide/metformin fixed-dose combination (FDC therapy (PrandiMet®; Novo Nordisk, Bagsværd, Denmark has been approved for use in the USA. This FDC is a rational second-line therapy given the complementary mechanisms of action of the components. Repaglinide is a rapidly absorbed, short-acting insulin secretagogue targeting postprandial glucose excursions; metformin is an insulin sensitizer with a longer duration of action that principally regulates basal glucose levels. A pivotal, 26-week, randomized study with repaglinide/metformin FDC therapy has been conducted in patients experiencing suboptimal control with previous oral antidiabetes therapy. Repaglinide/metformin FDC improved glycemic control and weight neutrality without adverse effects on lipid profiles. There were no major hypoglycemic episodes and patients expressed greater satisfaction with repaglinide/metformin FDC than previous treatments. Repaglinide/metformin FDC is expected to be more convenient than individual tablets for patients taking repaglinide and metformin in loose combination, and it is expected to improve glycemic control in patients for whom meglitinide or metformin monotherapies provide inadequate control.Keywords: type 2 diabetes, metformin, repaglinide, PrandiMet®, fixed-dose combination

  13. [Insufficient medication compliance in Parkinson's disease

    NARCIS (Netherlands)

    Aerts, M.B.; Eijk, M. van der; Kramers, C.; Bloem, B.R.

    2011-01-01

    Medication compliance is generally suboptimal, particularly in patients with complex polypharmacy. This generic treatment problem is described here for Parkinson's disease (PD). We would expect patients with PD to have good medication compliance, since missed doses immediately result in worsening of

  14. Dose rate effect on low-dose hyper-radiosensitivity with cells in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon-Min; Kim, Eun-Hee [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Low-dose hyper-radiosensitivity (HRS) is the phenomenon that mammalian cells exhibit higher sensitivity to radiation at low doses (< 0.5 Gy) than expected by the linear-quadratic model. At doses above 0.5Gy, the cellular response is recovered to the level expected by the linear-quadratic model. This transition is called the increased radio-resistance (IRR). HRS was first verified using Chinese hamster V79 cells in vitro by Marples and has been confirmed in studies with other cell lines including human normal and tumor cells. HRS is known to be induced by inactivation of ataxia telangiectasia-mutated (ATM), which plays a key role in repairing DNA damages. Considering the connection between ATM and HRS, one can infer that dose rate may affect cellular response regarding HRS at low doses. In this study, we quantitated the effect of dose rate on HRS by clonogenic assay with normal and tumor cells. The HRS of cells at low dose exposures is a phenomenon already known. In this study, we observed HRS of rat normal diencephalon cells and rat gliosarcoma cells at doses below 1 Gy. In addition, we found that dose rate mattered. HRS occurred at low doses, but only when total dose was delivered at a rate below certain level.

  15. Vancomycin Dosing in Obese Patients: Special Considerations and Novel Dosing Strategies.

    Science.gov (United States)

    Durand, Cheryl; Bylo, Mary; Howard, Brian; Belliveau, Paul

    2018-06-01

    To review the literature regarding vancomycin pharmacokinetics in obese patients and strategies used to improve dosing in this population. PubMed, EMBASE (1974 to November 2017), and Google Scholar searches were conducted using the search terms vancomycin, obese, obesity, pharmacokinetics, strategy, and dosing. Additional articles were selected from reference lists of selected studies. Included articles were those published in English with a primary focus on vancomycin pharmacokinetic parameters in obese patients and practical vancomycin dosing strategies, clinical experiences, or challenges of dosing vancomycin in this population. Volume of distribution and clearance are the pharmacokinetic parameters that most often affect vancomycin dosing in obese patients; both are increased in this population. Challenges with dosing in obese patients include inconsistent and inadequate dosing, observations that the obese population may not be homogeneous, and reports of an increased likelihood of supratherapeutic trough concentrations. Investigators have revised and developed dosing and monitoring protocols to address these challenges. These approaches improved target trough attainment to varying degrees. Some of the vancomycin dosing approaches provided promising results in obese patients, but there were notable differences in methods used to develop these approaches, and sample sizes were small. Although some approaches can be considered for validation in individual institutions, further research is warranted. This may include validating approaches in larger populations with narrower obesity severity ranges, investigating target attainment in indication-specific target ranges, and evaluating the impact of different dosing weights and methods of creatinine clearance calculation.

  16. Patient dose measurement and dose reduction in East Anglia (UK)

    International Nuclear Information System (INIS)

    Wade, J.P.; Goldstone, K.E.; Dendy, P.P.

    1995-01-01

    At the end of 1990 a programme of patient dose measurements was introduced as part of the quality assurance service already provided for X ray departments throughout the East Anglian Health Region (UK). Thermoluminescence dosemeters (TLDs) were used to measure over 1200 skin entrance surface doses for four common radiographic views in 33 hospitals in both the NHS and private sector. The four views were chosen to cover a wide range of equipment and techniques. The data collected have enabled Regional reference doses to be set which, for all views considered, fall below the National Radiological Protection Board (NRPB) Reference levels. In departments which exceeded reference levels, techniques were reviewed, improvements suggested and doses re-measured, in accordance with the recommended procedure for patient dose audit. A significant finding was that, given appropriate controls, X ray departments in the private sector could achieve the same acceptably low doses as NHS departments. (Author)

  17. Dependence of total dose response of bipolar linear microcircuits on applied dose rate

    International Nuclear Information System (INIS)

    McClure, S.; Will, W.; Perry, G.; Pease, R.L.

    1994-01-01

    The effect of dose rate on the total dose radiation hardness of three commercial bipolar linear microcircuits is investigated. Total dose tests of linear bipolar microcircuits show larger degradation at 0.167 rad/s than at 90 rad/s even after the high dose rate test is followed by a room temperature plus a 100 C anneal. No systematic correlation could be found for degradation at low dose rate versus high dose rate and anneal. Comparison of the low dose rate with the high dose rate anneal data indicates that MIL-STD-883, method 1019.4 is not a worst-case test method when applied to bipolar microcircuits for low dose rate space applications

  18. Insignificant levels of dose

    International Nuclear Information System (INIS)

    Webb, G.A.M.; McLean, A.S.

    1977-01-01

    The procedures recommended by the International Commission on Radiological Protection (ICRP) for making decisions concerning controllable sources of radiation exposure of the public include 'justification' and 'optimisation'. The tool recommended by the ICRP for reaching these decisions is collective dose or dose commitment supplemented by consideration of doses to individuals. In both these considerations the practical problem arises of whether very small doses to large numbers of people should contribute to the final decision-making process. It may be that at levels of dose which are small increments on natural background, the relationship between dose and effect is linear even though the slope may be close to zero. If so, collective dose is a meaningful concept and the calculation of total detriment for the purpose of justification could legitimately include all doses. In the calculation of collective doses for the purpose of optimisation, which involves decisions on how much money or resource should be allocated to dose reduction, it is necessary to appraise radiation detriment realistically. At low levels of dose to the individual such as those small by comparison with variations in natural background within the UK, the risk to the individual is such that his well-being will not be significantly changed by the presence or absence of the radiation dose. These small doses, which are well below the point at which an individual attaches significance, should not carry a societal significance. Societal acceptance of risk is analysed with a view to assessing a level of possible risk, and hence dose, below which resources should not in general be diverted to secure further reduction. A formulation for collective dose commitment is proposed incorporating a cut-off to exclude insignificant doses. The implications of this formulation in practical situations are discussed

  19. Case Example of Dose Optimization Using Data From Bortezomib Dose-Finding Clinical Trials.

    Science.gov (United States)

    Lee, Shing M; Backenroth, Daniel; Cheung, Ying Kuen Ken; Hershman, Dawn L; Vulih, Diana; Anderson, Barry; Ivy, Percy; Minasian, Lori

    2016-04-20

    The current dose-finding methodology for estimating the maximum tolerated dose of investigational anticancer agents is based on the cytotoxic chemotherapy paradigm. Molecularly targeted agents (MTAs) have different toxicity profiles, which may lead to more long-lasting mild or moderate toxicities as well as to late-onset and cumulative toxicities. Several approved MTAs have been poorly tolerated during long-term administration, leading to postmarketing dose optimization studies to re-evaluate the optimal treatment dose. Using data from completed bortezomib dose-finding trials, we explore its toxicity profile, optimize its dose, and examine the appropriateness of current designs for identifying an optimal dose. We classified the toxicities captured from 481 patients in 14 bortezomib dose-finding studies conducted through the National Cancer Institute Cancer Therapy Evaluation Program, computed the incidence of late-onset toxicities, and compared the incidence of dose-limiting toxicities (DLTs) among groups of patients receiving different doses of bortezomib. A total of 13,008 toxicities were captured: 46% of patients' first DLTs and 88% of dose reductions or discontinuations of treatment because of toxicity were observed after the first cycle. Moreover, for the approved dose of 1.3 mg/m(2), the estimated cumulative incidence of DLT was > 50%, and the estimated cumulative incidence of dose reduction or treatment discontinuation because of toxicity was nearly 40%. When considering the entire course of treatment, the approved bortezomib dose exceeds the conventional ceiling DLT rate of 20% to 33%. Retrospective analysis of trial data provides an opportunity for dose optimization of MTAs. Future dose-finding studies of MTAs should take into account late-onset toxicities to ensure that a tolerable dose is identified for future efficacy and comparative trials. © 2016 by American Society of Clinical Oncology.

  20. Occupational Doses and the Contribution to the Population Dose in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Han, Seung Jae; Kyu, Hwan Jeong [KINS, Daejeon (Korea, Republic of)

    2016-05-15

    The purpose of this study is to evaluate the occupational exposure records in terms of the control of exposure for radiation workers and dose reduction. The study includes the estimates of the number of people exposed occupationally, the effective collective doses and mean doses to those exposed. In addition, the study includes an estimate of the contribution of occupational exposure to the Korean population dose. The exposure of radiation workers in occupational field includes medical radiology, industrial applications such as radiography, nuclear power, and some research activities. Occupational exposure from medical radiology practices includes the contributions from diagnostic x-ray procedures, dental radiography, nuclear medicine and radiation therapy. The control of exposure for radiation workers, and the measures necessary to maintain radiation exposure as low as reasonably achievable (ALARA) are specified in Subparagraph 3 and Subparagraph 4 of Article 91 (1) of the Korea Nuclear Safety Act (KNSA), respectively. Therefore, from a regulatory perspective, the exposure data of the workers are primarily for verification of the adequacy of the control of exposure, radiation protection and implementation of ALARA. The number of people exposed occupationally, the effective collective doses and mean doses to those exposed, and average effective doses from occupational exposure during the period of 2009 to 2013 have been evaluated. In general, radiation workers were increasing in number annually, but the mean doses for those exposed each year showed the control of exposures were mostly considered met within the dose limit in KNSA. Nevertheless, it was shown that the continuous efforts would be needed to reduce doses and thus to implement ALARA regulatory requirements. In radiation occupations, the application of ICRP radiation protection principles will ensure good practice and decreasing exposures. Over the period of 5 years, the contributions of the annual

  1. Occupational Doses and the Contribution to the Population Dose in Korea

    International Nuclear Information System (INIS)

    Han, Seung Jae; Kyu, Hwan Jeong

    2016-01-01

    The purpose of this study is to evaluate the occupational exposure records in terms of the control of exposure for radiation workers and dose reduction. The study includes the estimates of the number of people exposed occupationally, the effective collective doses and mean doses to those exposed. In addition, the study includes an estimate of the contribution of occupational exposure to the Korean population dose. The exposure of radiation workers in occupational field includes medical radiology, industrial applications such as radiography, nuclear power, and some research activities. Occupational exposure from medical radiology practices includes the contributions from diagnostic x-ray procedures, dental radiography, nuclear medicine and radiation therapy. The control of exposure for radiation workers, and the measures necessary to maintain radiation exposure as low as reasonably achievable (ALARA) are specified in Subparagraph 3 and Subparagraph 4 of Article 91 (1) of the Korea Nuclear Safety Act (KNSA), respectively. Therefore, from a regulatory perspective, the exposure data of the workers are primarily for verification of the adequacy of the control of exposure, radiation protection and implementation of ALARA. The number of people exposed occupationally, the effective collective doses and mean doses to those exposed, and average effective doses from occupational exposure during the period of 2009 to 2013 have been evaluated. In general, radiation workers were increasing in number annually, but the mean doses for those exposed each year showed the control of exposures were mostly considered met within the dose limit in KNSA. Nevertheless, it was shown that the continuous efforts would be needed to reduce doses and thus to implement ALARA regulatory requirements. In radiation occupations, the application of ICRP radiation protection principles will ensure good practice and decreasing exposures. Over the period of 5 years, the contributions of the annual

  2. Low-dose computed tomography image restoration using previous normal-dose scan

    International Nuclear Information System (INIS)

    Ma, Jianhua; Huang, Jing; Feng, Qianjin; Zhang, Hua; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan

    2011-01-01

    Purpose: In current computed tomography (CT) examinations, the associated x-ray radiation dose is of a significant concern to patients and operators. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) or kVp parameter (or delivering less x-ray energy to the body) as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and the noise would propagate into the CT image if no adequate noise control is applied during image reconstruction. Since a normal-dose high diagnostic CT image scanned previously may be available in some clinical applications, such as CT perfusion imaging and CT angiography (CTA), this paper presents an innovative way to utilize the normal-dose scan as a priori information to induce signal restoration of the current low-dose CT image series. Methods: Unlike conventional local operations on neighboring image voxels, nonlocal means (NLM) algorithm utilizes the redundancy of information across the whole image. This paper adapts the NLM to utilize the redundancy of information in the previous normal-dose scan and further exploits ways to optimize the nonlocal weights for low-dose image restoration in the NLM framework. The resulting algorithm is called the previous normal-dose scan induced nonlocal means (ndiNLM). Because of the optimized nature of nonlocal weights calculation, the ndiNLM algorithm does not depend heavily on image registration between the current low-dose and the previous normal-dose CT scans. Furthermore, the smoothing parameter involved in the ndiNLM algorithm can be adaptively estimated based on the image noise relationship between the current low-dose and the previous normal-dose scanning protocols. Results: Qualitative and quantitative evaluations were carried out on a physical phantom as well as clinical abdominal and brain perfusion CT scans in terms of accuracy and resolution properties. The gain by the use

  3. Conversion from tooth enamel dose to organ doses for electron spin resonance dosimetry

    International Nuclear Information System (INIS)

    Takahashi, Fumiaki; Yamaguchi, Yasuhiro; Saito, Kimiaki; Hamada, Tatsuji

    2002-01-01

    Conversion from tooth enamel dose to organ doses was analyzed to establish a method of retrospective individual dose assessment against external photon exposure by electron spin resonance (ESR) dosimetry. Dose to tooth enamel was obtained by Monte Carlo calculations using a modified MIRD-type phantom with a teeth part. The calculated tooth enamel doses were verified by measurements with thermo-luminescence dosimeters inserted in a physical head phantom. Energy and angular dependences of tooth enamel dose were compared with those of other organ doses. Additional Monte Carlo calculations were performed to study the effect of human model on the tooth enamel dose with a voxel-type phantom, which was based on computed tomography images of the physical phantom. The data derived with the modified MIRD-type phantom were applied to convert from tooth enamel dose to organ doses against external photon exposure in a hypothesized field, where scattered radiation was taken into account. The results indicated that energy distribution of photons incident to a human body is required to evaluate precisely an individual dose based on ESR dosimetry for teeth. (author)

  4. When is a dose not a dose?

    International Nuclear Information System (INIS)

    Green, Patrick

    1992-01-01

    There is confusion over radiation dose limits between the International Commission on Radiological Protection, the National Radiological Protection Board and the Ministry of Agriculture, Fisheries and Food (MAFF), reports a Friends of the Earth's radiation campaigner. MAFF is suggesting the inadequate ICRP public dose limit does not apply to public exposures which arise from environmental contamination from past radioactive discharges. (author)

  5. Determination of Entrance Skin Doses and Organ Doses for Medical X Ray Examinations

    International Nuclear Information System (INIS)

    Tung, C.J.; Cheng, C.Y.; Chao, T.C.; Tsai, H.Y.

    1999-01-01

    A national survey of patient doses for diagnostic X ray radiographs is planned in Taiwan. Entrance skin doses and organ doses for all installed X ray machines will be investigated. A pilot study has been carried out for the national survey to develop a protocol for the dose assessment. Entrance skin doses and organ doses were measured by thermoluminescence dosemeters and calculated by Monte Carlo simulations for several X ray examinations. The conversion factor from free air entrance absorbed dose to entrance skin dose was derived. A formula for the computation of entrance skin doses from inputs of kV p , mA.s, source to skin distance, aluminium filtration, and generator rectifying was constructed. Organ doses were measured using a RANDO phantom and calculated using a mathematical phantom. All data will be passed to the Atomic Energy Council for developing a programme of national survey and regulatory controls for diagnostic X ray examinations. (author)

  6. Occupational dose constraint

    International Nuclear Information System (INIS)

    Heilbron Filho, Paulo Fernando Lavalle; Xavier, Ana Maria

    2005-01-01

    The revision process of the international radiological protection regulations has resulted in the adoption of new concepts, such as practice, intervention, avoidable and restriction of dose (dose constraint). The latter deserving of special mention since it may involve reducing a priori of the dose limits established both for the public and to individuals occupationally exposed, values that can be further reduced, depending on the application of the principle of optimization. This article aims to present, with clarity, from the criteria adopted to define dose constraint values to the public, a methodology to establish the dose constraint values for occupationally exposed individuals, as well as an example of the application of this methodology to the practice of industrial radiography

  7. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  8. Modeling DNA?damage-induced pneumopathy in mice: insight from danger signaling cascades

    OpenAIRE

    Wirsd?rfer, Florian; Jendrossek, Verena

    2017-01-01

    Radiation-induced pneumonitis and fibrosis represent severe and dose-limiting side effects in the radiotherapy of thorax-associated neoplasms leading to decreased quality of life or - as a consequence of treatment with suboptimal radiation doses - to fatal outcomes by local recurrence or metastatic disease. It is assumed that the initial radiation-induced damage to the resident cells triggers a multifaceted damage-signalling cascade in irradiated normal tissues including a multifactorial secr...

  9. Dose reconstruction in deforming lung anatomy: Dose grid size effects and clinical implications

    International Nuclear Information System (INIS)

    Rosu, Mihaela; Chetty, Indrin J.; Balter, James M.; Kessler, Marc L.; McShan, Daniel L.; Ten Haken, Randall K.

    2005-01-01

    In this study we investigated the accumulation of dose to a deforming anatomy (such as lung) based on voxel tracking and by using time weighting factors derived from a breathing probability distribution function (p.d.f.). A mutual information registration scheme (using thin-plate spline warping) provided a transformation that allows the tracking of points between exhale and inhale treatment planning datasets (and/or intermediate state scans). The dose distributions were computed at the same resolution on each dataset using the Dose Planning Method (DPM) Monte Carlo code. Two accumulation/interpolation approaches were assessed. The first maps exhale dose grid points onto the inhale scan, estimates the doses at the 'tracked' locations by trilinear interpolation and scores the accumulated doses (via the p.d.f.) on the original exhale data set. In the second approach, the 'volume' associated with each exhale dose grid point (exhale dose voxel) is first subdivided into octants, the center of each octant is mapped to locations on the inhale dose grid and doses are estimated by trilinear interpolation. The octant doses are then averaged to form the inhale voxel dose and scored at the original exhale dose grid point location. Differences between the interpolation schemes are voxel size and tissue density dependent, but in general appear primarily only in regions with steep dose gradients (e.g., penumbra). Their magnitude (small regions of few percent differences) is less than the alterations in dose due to positional and shape changes from breathing in the first place. Thus, for sufficiently small dose grid point spacing, and relative to organ motion and deformation, differences due solely to the interpolation are unlikely to result in clinically significant differences to volume-based evaluation metrics such as mean lung dose (MLD) and tumor equivalent uniform dose (gEUD). The overall effects of deformation vary among patients. They depend on the tumor location, field

  10. Rising burden of gout in the UK but continuing suboptimal management: a nationwide population study

    Science.gov (United States)

    Kuo, Chang-Fu; Grainge, Matthew J; Mallen, Christian; Zhang, Weiya; Doherty, Michael

    2015-01-01

    Objectives To describe trends in the epidemiology of gout and patterns of urate-lowering treatment (ULT) in the UK general population from 1997 to 2012. Methods We used the Clinical Practice Research Datalink to estimate the prevalence and incidence of gout for each calendar year from 1997 to 2012. We also investigated the pattern of gout management for both prevalent and incident gout patients. Results In 2012, the prevalence of gout was 2.49% (95% CI 2.48% to 2.51%) and the incidence was 1.77 (95% CI 1.73 to 1.81) per 1000 person-years. Prevalence and incidence both were significantly higher in 2012 than in 1997, with a 63.9% increase in prevalence and 29.6% increase in incidence over this period. Regions with highest prevalence and incidence were the North East and Wales. Among prevalent gout patients in 2012, only 48.48% (95% CI 48.08% to 48.89%) were being consulted specifically for gout or treated with ULT and of these 37.63% (95% CI 37.28% to 38.99%) received ULT. In addition, only 18.6% (95% CI 17.6% to 19.6%) of incident gout patients received ULT within 6 months and 27.3% (95% CI 26.1% to 28.5%) within 12 months of diagnosis. The management of prevalent and incident gout patients remained essentially the same during the study period, although the percentage of adherent patients improved from 28.28% (95% CI 27.33% to 29.26%) in 1997 to 39.66% (95% CI 39.11% to 40.22%) in 2012. Conclusions In recent years, both the prevalence and incidence of gout have increased significantly in the UK. Suboptimal use of ULT has not changed between 1997 and 2012. Patient adherence has improved during the study period, but it remains poor. PMID:24431399

  11. Radon Exposure and the Definition of Low Doses-The Problem of Spatial Dose Distribution.

    Science.gov (United States)

    Madas, Balázs G

    2016-07-01

    Investigating the health effects of low doses of ionizing radiation is considered to be one of the most important fields in radiological protection research. Although the definition of low dose given by a dose range seems to be clear, it leaves some open questions. For example, the time frame and the target volume in which absorbed dose is measured have to be defined. While dose rate is considered in the current system of radiological protection, the same cancer risk is associated with all exposures, resulting in a given amount of energy absorbed by a single target cell or distributed among all the target cells of a given organ. However, the biological effects and so the health consequences of these extreme exposure scenarios are unlikely to be the same. Due to the heterogeneous deposition of radon progeny within the lungs, heterogeneous radiation exposure becomes a practical issue in radiological protection. While the macroscopic dose is still within the low dose range, local tissue doses on the order of Grays can be reached in the most exposed parts of the bronchial airways. It can be concluded that progress in low dose research needs not only low dose but also high dose experiments where small parts of a biological sample receive doses on the order of Grays, while the average dose over the whole sample remains low. A narrow interpretation of low dose research might exclude investigations with high relevance to radiological protection. Therefore, studies important to radiological protection should be performed in the frame of low dose research even if the applied doses do not fit in the dose range used for the definition of low doses.

  12. Physiological and immunological changes following exposure to low versus high-dose ionizing irradiation; comparative analysis with dose rate and cumulative dose

    International Nuclear Information System (INIS)

    Heesun, Kim; Heewon, Jang; Soungyeon, Song; Shinhye, Oh; Cukcheul, Shin; Meeseon, Jeong; Chasoon, Kim; Kwnaghee, Yang; Seonyoung, Nam; Jiyoung, Kim; Youngwoo, Jin; Changyoung, Cha

    2008-01-01

    Full text: While high-dose of ionizing radiation is generally harmful and causes damage to living organisms some reports suggest low-dose of radiation may not be as damaging as previously thought. Despite increasing evidence regarding the protective effect of low-dose radiation, no studies have directly compared the exact dose-response pattern by high- and low-dose of radiation exposed at high-and low-dose rate. This study aims to explore the cellular and molecular changes in mice exposed to low- and high-dose of radiation exposed at low- and high-dose rate. When C57BL/6 mice (Female, 6 weeks) were exposed at high-dose rate, 0.8 Gy/min, no significant change on the level of WBC, RBC, or platelets was observed up to total dose of 0.5 Gy. However, 2 Gy of radiation caused dramatic reduction in the level of white blood cells (WBC) and platelets. This reduction was accompanied by increased DNA damage in hematopoietic environments. The reduction of WBC was mainly due to the reduction in the number of CD4+ T cells and CD19+ B cells. CD8+ T cells and NK cells appeared to be relatively resistant to high-dose of radiation. This change was also accompanied by the reduction of T- and B- progenitor cells in the bone marrow. In contrast, no significant changes of the number of CD4+ T, CD8+ T, NK, and B cells were observed in the spleen of mice exposed at low-dose-rate (0.7 m Gy/h or 3.95 mGy/h) for up to 2 Gy, suggesting that low-dose radiation does not alter cellular distribution in the spleen. Nevertheless, mice exposed to low-dose radiation exhibited elevation of VEGF, MCP-1, IL-4, Leptin, IL-3, and Tpo in the peripheral blood and slight increases in MIP-2, RANTES, and IL-2 in the spleen. This suggests that chronic γ-radiation can stimulate immune function without causing damage to the immune components of the body. Taken together, these data indicate hormesis of low-dose radiation, which could be attributed to the stimulation of immune function. Dose rate rather than total

  13. Suboptimal inhibition of protease activity in human immunodeficiency virus type 1: Effects on virion morphogenesis and RNA maturation

    International Nuclear Information System (INIS)

    Moore, Michael D.; Fu, William; Soheilian, Ferri; Nagashima, Kunio; Ptak, Roger G.; Pathak, Vinay K.; Hu, Wei-Shau

    2008-01-01

    Protease activity within nascently released human immunodeficiency virus type 1 (HIV-1) particles is responsible for the cleavage of the viral polyproteins Gag and Gag-Pol into their constituent parts, which results in the subsequent condensation of the mature conical core surrounding the viral genomic RNA. Concomitant with viral maturation is a conformational change in the packaged viral RNA from a loosely associated dimer into a more thermodynamically stable form. In this study we used suboptimal concentrations of two protease inhibitors, lopinavir and atazanavir, to study their effects on Gag polyprotein processing and on the properties of the RNA in treated virions. Analysis of the treated virions demonstrated that even with high levels of inhibition of viral infectivity (IC 90 ), most of the Gag and Gag-Pol polyproteins were processed, although slight but significant increases in processing intermediates of Gag were detected. Drug treatments also caused a significant increase in the proportion of viruses displaying either immature or aberrant mature morphologies. The aberrant mature particles were characterized by an electron-dense region at the viral periphery and an electron-lucent core structure in the viral center, possibly indicating exclusion of the genomic RNA from these viral cores. Intriguingly, drug treatments caused only a slight decrease in overall thermodynamic stability of the viral RNA dimer, suggesting that the dimeric viral RNA was able to mature in the absence of correct core condensation

  14. Do pigeons (Columba livia) use information about the absence of food appropriately? A further look into suboptimal choice.

    Science.gov (United States)

    Fortes, Inês; Machado, Armando; Vasconcelos, Marco

    2017-11-01

    In the natural environment, when an animal encounters a stimulus that signals the absence of food-a 'bad-news' stimulus-it will most likely redirect its search to another patch or prey. Because the animal does not pay the opportunity cost of waiting in the presence of a bad-news stimulus, the properties of the stimulus (e.g., its duration and probability) may have little impact in the evolution of the decision processes deployed in these circumstances. Hence, in the laboratory, when animals are forced to experience a bad-news stimulus they seem to ignore its duration, even though they pay the cost of waiting. Under certain circumstances, this insensitivity to the opportunity cost can lead to suboptimal preferences, such as a preference for an option yielding a low rather than a high rate of reinforcement. In 2 experiments, we tested Vasconcelos, Monteiro, and Kacelnik's (2015) assumption that, if given the opportunity, animals will escape the bad-news stimulus. To predict when an escape response should occur, we incorporated ideas from the prey choice model into Vasconcelos et al. (2015) model and made 2 novel predictions. Namely, both longer intertrial intervals and longer durations of signals predicting food or no food should lead to higher proportions of escape responses. The results of 2 experiments with pigeons supported these predictions. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  15. Dose rate correction in medium dose rate brachytherapy for carcinoma cervix

    International Nuclear Information System (INIS)

    Patel, F.D.; Negi, P.S.; Sharma, S.C.; Kapoor, R.; Singh, D.P.; Ghoshal, S.

    1998-01-01

    Purpose: To establish the magnitude of brachytherapy dose reduction required for stage IIB and III carcinoma cervix patients treated by external radiation and medium dose rate (MDR) brachytherapy at a dose rate of 220±10 cGy/h at point A.Materials and methods: In study-I, at the time of MDR brachytherapy application at a dose rate of 220±10 cGy/h at point A, patients received either 3060 cGy, a 12.5% dose reduction (MDR-12.5), or 2450 cGy, a 30% dose reduction (MDR-30), to point A and they were compared to a group of previously treated LDR patients who received 3500 cGy to point A at a dose rate of 55-65 cGy/h. Study-II was a prospective randomized trial and patients received either 2450 cGy, a 30% dose reduction (MDR-II (30)) or 2800 cGy, a 20% dose reduction (MDR-II (20)), at point A. Patients were evaluated for local control of disease and morbidity. Results: In study-I the 5-year actuarial local control rate in the MDR-30 and MDR-12.5 groups was 71.7±10% and 70.5±10%, respectively, compared to 63.4±10% in the LDR group. However, the actuarial morbidity (all grades) in the MDR-12.5 group was 58.5±14% as against 34.9±9% in the LDR group (P 3 developed complication as against 62.5% of those receiving a rectal BED of (140 3 (χ 2 =46.43; P<0.001). Conclusion: We suggest that at a dose rate of 220±10 cGy/h at point A the brachytherapy dose reduction factor should be around 30%, as suggested by radiobiological data, to keep the morbidity as low as possible without compromising the local control rates. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  16. Controllable dose

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Anaya M, R.A.

    2004-01-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  17. Application of biological dose concept in dose optimization for conformal radiotherapy of prostate carcinoma

    International Nuclear Information System (INIS)

    Li Yunhai; Liao Yuan; Zhou Lijun; Pan Ziqiang; Feng Yan

    2003-01-01

    Objective: On basis of physical dose optimization, LQ model was used to investigate the difference between the curves of biological effective dose and physical isodose. The influence of applying the biological dose concept on three dimensional conformal radiotherapy of prostate carcinoma was discussed. Methods: Four treatment plannings were designed for physical dose optimization: three fields, four-box fields, five fields and six fields. Target dose uniformity and protection of the critical tissue-rectum were used as the principal standard for designing the treatment planning. Biological effective dose (BED) was calculated by LQ model. The difference between the BED curve drawn in the central layer and the physical isodose curve was studied. The difference between the adjusted physical dose (APD) and the physical dose was also studied. Results: Five field planning was the best in target dose uniformity and protection of the critical tissue-rectum. The physical dose was uniform in the target, but the biological effective doses revealed great discrepancy in the biological model. Adjusted physical dose distribution also displayed larger discrepancy than the physical dose unadjusted. Conclusions: Intensified Modulated Radiotherapy (IMRT) technique with inversion planning using biological dose concept may be much more advantageous to reach a high tumor control probability and low normal tissue complication probability

  18. Measurements of dose on build-up region, surface dose and outlet dose by a 10 MeV Linear accelerator

    International Nuclear Information System (INIS)

    Souza, C.N. de; Khoury, H.J.

    1987-01-01

    The dose on buildup region and the surface dose for a 10 MeV photon beam from a linear acelerator (Mevatrom-74, Siemens) is studied. The influence of the tray of polycarbonate on the surface dose is determined. (M.A.C.) [pt

  19. Paediatric dose display

    International Nuclear Information System (INIS)

    Griffin, D.W.; Derges, S.; Hesslewood, S.

    1984-01-01

    A compact, inexpensive unit, based on an 8085 microprocessor, has been designed for calculating doses of intravenous radioactive injections for children. It has been used successfully for over a year. The dose is calculated from the body surface area and the result displayed in MBq. The operator can obtain the required dose on a twelve character alphanumeric display by entering the age of the patient and the adult dose using a hexadecimal keyboard. Circuit description, memory map and input/output, and firmware are dealt with. (U.K.)

  20. Research on low radiation doses - A better understanding of low doses

    International Nuclear Information System (INIS)

    2016-01-01

    Radiation doses below 100 mSv are called low doses. Epidemiological research on the health hazards of low doses are difficult to do because numerous pathologies, particularly cancer, appear lifelong for genetical or environmental causes without any link with irradiation and it is very difficult to identify the real cause of a cancer. Another concern is that the impact on human health is weak and are observed only after a long period after irradiation. These features make epidemiological studies cumbersome to implement since they require vast cohorts and a very long-term follow-up. The extrapolation of the effects of higher doses to the domain of low doses does not meet reality and it is why the European Union takes part into the financing of such research. In order to gain efficiency, scientists work together through various European networks among them: HLEG (High Level Expert Group On European Low Dose Risk Research) or MELODI (Multidisciplinary European Low Dose Initiative). Several programs are underway or have been recently launched: -) the impact of Cesium contamination on children's health (Epice program), -) the study of the impact of medical imaging on children, -) the study of the health of children living near nuclear facilities, -) the relationship between radon and lung cancer, -) the effect of occupational low radiation doses, -) the effect of uranium dissolved in water on living organisms (Envirhom program). (A.C.)

  1. Dose Response Model of Biological Reaction to Low Dose Rate Gamma Radiation

    International Nuclear Information System (INIS)

    Magae, J.; Furikawa, C.; Hoshi, Y.; Kawakami, Y.; Ogata, H.

    2004-01-01

    It is necessary to use reproducible and stable indicators to evaluate biological responses to long term irradiation at low dose-rate. They should be simple and quantitative enough to produce the results statistically accurate, because we have to analyze the subtle changes of biological responses around background level at low dose. For these purposes we chose micronucleus formation of U2OS, a human osteosarcoma cell line, as indicators of biological responses. Cells were exposed to gamma ray in irradiation rom bearing 50,000 Ci 60Co. After irradiation, they were cultured for 24 h in the presence of cytochalasin B to block cytokinesis, and cytoplasm and nucleus were stained with DAPI and prospidium iodide, respectively. the number of binuclear cells bearing micronuclei was counted under a fluorescence microscope. Dose rate in the irradiation room was measured with PLD. Dose response of PLD is linear between 1 mGy to 10 Gy, and standard deviation of triplicate count was several percent of mean value. We fitted statistically dose response curves to the data, and they were plotted on the coordinate of linearly scale response and dose. The results followed to the straight line passing through the origin of the coordinate axes between 0.1-5 Gy, and dose and does rate effectiveness factor (DDREF) was less than 2 when cells were irradiated for 1-10 min. Difference of the percent binuclear cells bearing micronucleus between irradiated cells and control cells was not statistically significant at the dose above 0.1 Gy when 5,000 binuclear cells were analyzed. In contrast, dose response curves never followed LNT, when cells were irradiated for 7 to 124 days. Difference of the percent binuclear cells bearing micronucleus between irradiated cells and control cells was not statistically significant at the dose below 6 Gy, when cells were continuously irradiated for 124 days. These results suggest that dose response curve of biological reaction is remarkably affected by exposure

  2. Doses from portable gauges

    International Nuclear Information System (INIS)

    Linauskas, S.H.

    1988-08-01

    Field studies to measure actual radiation exposures of operators of commercial moisture-density gauges were undertaken in several regions of Canada. Newly developed bubble detector dosimeter technology and conventional dosimetry such as thermoluminescent dosimeters (TLDs), integrating electronic dosimeters (DRDs), and CR-39 neutron track-etch detectors were used to estimate the doses received by 23 moisture-density gauge operators and maintenance staff. These radiation dose estimates were supported by mapping radiation fields and accounting for the time an operator was near a gauge. Major findings indicate that gauge maintenance and servicing workers were more likely than gauge operators to receive exposures above the level of 5 mSv, and that neutron doses were roughly the same as gamma doses. Gauge operators receive approximately 75% of their dose when transporting and carrying the gauge. Dose to their hands is similar to the dose to their trunks, but the dose to their feet area is 6 to 30 times higher. Gamma radiation is the primary source of radiation contributing to operator dose

  3. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan [Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States) and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States)

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  4. Comparative study of eye dose and chest dose received during radiopharmaceutical production processes

    International Nuclear Information System (INIS)

    Chindarkar, A.S.; Chavan, S.V.; Sawant, D.K.; Sahoo, L.; Gopalakrishnan, R.K.; Sneha, C.; Sachdev, S.S.; Dey, A.C.

    2018-01-01

    Radiopharmaceutical laboratory, BRIT, Vashi produces different radiopharmaceuticals of 131 I, 153 Sm, 99 Mo/ 99m Tc and 177 Lu. Principle gamma energies of these isotopes vary from 103 to 740 KeV and their maximum beta energies vary from 384 to 1214 KeV. In the light of the revised eye lens dose limit recommended in IAEA Basic Safety Standard Interim Edition No. GSR Part 3 (IAEA-2011), the study of radiation dose for eye lens was carried out using CaSO 4 : Dy based Thermo luminescence dosimeter (TLD). This TLD was worn at center of the forehead to measure eye lens dose. This TLD dose was then compared with chest TLD dose to deduce any correlation between these TLD doses. These TLD doses were assessed on quarterly basis. Eight quarter data of these TLD doses were compared

  5. Organ dose and effective dose with the EOS scanner in spine deformity surgery

    DEFF Research Database (Denmark)

    Heide Pedersen, Peter; Petersen, Asger Greval; Eiskjær, Søren Peter

    2016-01-01

    Organ dose and effective dose with the EOS scanner in spine deformity surgery. A study on anthropomorphic phantoms describing patient radiation exposure in full spine examinations. Authors: Peter Heide Pedersen, Asger Greval Petersen, Søren Peter Eiskjær. Background: Ionizing radiation potentially...... quality images while at the same time reducing radiation dose. At our institution we use the EOS for pre- and postoperative full spine examinations. Purpose: The purpose of the study is to make first time organ dose and effective dose evaluations with micro-dose settings in full spine examinations. Our...... hypothesis is that organ dose and effective doses can be reduced 5-10 times compared to standard settings, without too high image-quality trade off, resulting in a theoretical reduction of radiation induced cancer. Methods: Patient dosimetry is performed on anthropomorphic child phantoms, representing a 5...

  6. Mobile-Dose: A Dose-Meter Designed for Use in Automatic Machineries for Dose Manipulation in Nuclear Medicine

    Science.gov (United States)

    de Asmundis, Riccardo; Boiano, Alfonso; Ramaglia, Antonio

    2008-06-01

    Mobile-Dose has been designed for a very innovative use: the integration in a robotic machinery for automatic preparation of radioactive doses, to be injected to patients in Nuclear Medicine Departments, with real time measurement of the activity under preparation. Mobile-Dose gives a constant measurement of the dose during the filling of vials or syringes, triggering the end of the filling process based on a predefined dose limit. Several applications of Mobile-Dose have been delivered worldwide, from Italian hospitals and clinics to European and Japanese ones. The design of such an instrument and its integration in robotic machineries, was required by an Italian company specialised in radiation protection tools for nuclear applications, in the period 2001-2003. At the time of its design, apparently no commercial instruments with a suitable interfacing capability to the external world existed: we designed it in order to satisfy all the strict requirements coming from the medical aspects (precision within 10%, repeatability, stability, time response) and from the industrial conceiving principles that are mandatory to ensure a good reliability in such a complicated environment. The instrument is suitable to be used in standalone mode too, thanks to its portability and compactness and to the intelligent operator panel programmed for this purpose.

  7. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  8. Repair and dose-response at low doses

    International Nuclear Information System (INIS)

    Totter, J.R.; Weinberg, A.M.

    1977-04-01

    The DNA of each individual is subject to formation of some 2-4 x 10 14 ion pairs during the first 30 years of life from background radiation. If a single hit is sufficient to cause cancer, as is implicit in the linear, no-threshold theories, it is unclear why all individuals do not succumb to cancer, unless repair mechanisms operate to remove the damage. We describe a simple model in which the exposed population displays a distribution of repair thresholds. The dose-response at low dose is shown to depend on the shape of the threshold distribution at low thresholds. If the probability of zero threshold is zero, the response at low dose is quadratic. The model is used to resolve a longstanding discrepancy between observed incidence of leukemia at Nagasaki and the predictions of the usual linear hypothesis

  9. Automated extraction of radiation dose information from CT dose report images.

    Science.gov (United States)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2011-06-01

    The purpose of this article is to describe the development of an automated tool for retrieving texts from CT dose report images. Optical character recognition was adopted to perform text recognitions of CT dose report images. The developed tool is able to automate the process of analyzing multiple CT examinations, including text recognition, parsing, error correction, and exporting data to spreadsheets. The results were precise for total dose-length product (DLP) and were about 95% accurate for CT dose index and DLP of scanned series.

  10. The patient dose survey and dose reduction in diagnostic radiology

    International Nuclear Information System (INIS)

    Dang Thanh Luong; Duong Van Vinh; Ha Ngoc Thach

    2000-01-01

    This paper presented the results of the patient dose survey in some hospitals in Hanoi from 1995 to 1997. The main investigated types of the X-ray examination were: Chest PA, LAT; Skull PA/AP, LAT; Lumbar spine AP, LAT; and Pelvis AP. The fluctuation of the entrance surface doses (ESD) was too large, even in the same type of X-ray examination and X-ray facility. It was found that the ratio of maximum and minimum ESD were ranged from 1.5 to 18. The mean values of ESD for chest and skull were higher than CEC recommended values, while the mean values of lumbar spine and pelvis were smaller than that of CEC recommended values. The result of dose intercomparison was also reported. Some methods of dose reduction were applied for improving the patient dose in X-ray departments such as a high kV technique, high sensitive screen-film combination. (author)

  11. From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning

    International Nuclear Information System (INIS)

    Thieke, Christian; Bortfeld, Thomas; Niemierko, Andrzej; Nill, Simeon

    2003-01-01

    Optimization algorithms in inverse radiotherapy planning need information about the desired dose distribution. Usually the planner defines physical dose constraints for each structure of the treatment plan, either in form of minimum and maximum doses or as dose-volume constraints. The concept of equivalent uniform dose (EUD) was designed to describe dose distributions with a higher clinical relevance. In this paper, we present a method to consider the EUD as an optimization constraint by using the method of projections onto convex sets (POCS). In each iteration of the optimization loop, for the actual dose distribution of an organ that violates an EUD constraint a new dose distribution is calculated that satisfies the EUD constraint, leading to voxel-based physical dose constraints. The new dose distribution is found by projecting the current one onto the convex set of all dose distributions fulfilling the EUD constraint. The algorithm is easy to integrate into existing inverse planning systems, and it allows the planner to choose between physical and EUD constraints separately for each structure. A clinical case of a head and neck tumor is optimized using three different sets of constraints: physical constraints for all structures, physical constraints for the target and EUD constraints for the organs at risk, and EUD constraints for all structures. The results show that the POCS method converges stable and given EUD constraints are reached closely

  12. Dose Reduction and Dose Management in Computed Tomography - State of the Art.

    Science.gov (United States)

    Zinsser, Dominik; Marcus, Roy; Othman, Ahmed E; Bamberg, Fabian; Nikolaou, Konstantin; Flohr, Thomas; Notohamiprodjo, Mike

    2018-03-13

     For years, the number of performed CT examinations has been rising. At the same time, computed tomography became more dose efficient. The aim of this article is to give an overview about the state of the art in dose reduction in CT and to highlight currently available tools in dose management.  By performing a literature research on Pubmed regarding dose reduction in CT, relevant articles were identified and analyzed.  Technical innovations with individual adaptation of tube current and voltage as well as iterative image reconstruction enable a considerable dose reduction with preserved image quality. At the same time, dedicated software tools are able to handle huge amounts of data and allow to optimize existing examination protocols.   · CT examinations are increasingly performed and contribute considerably to non-natural radiation exposure.. · A correct indication is crucial for each CT examination.. · The examination protocol has to be tailored to the medical question and patient.. · Multiple technical innovations enable considerable dose reduction with constant image quality.. · Dose management with dedicated software tools gains importance.. · Zinsser D, Marcus R, Othman AE et al. Dose reduction and dose management in computed tomography - State of the art. Fortschr Röntgenstr 2018; DOI: 10.1055/s-0044-101261. © Georg Thieme Verlag KG Stuttgart · New York.

  13. [Clinical applications of dosing algorithm in the predication of warfarin maintenance dose].

    Science.gov (United States)

    Huang, Sheng-wen; Xiang, Dao-kang; An, Bang-quan; Li, Gui-fang; Huang, Ling; Wu, Hai-li

    2011-12-27

    To evaluate the feasibility of clinical application for genetic based dosing algorithm in the predication of warfarin maintenance dose in Chinese population. The clinical data were collected and blood samples harvested from a total of 126 patients undergoing heart valve replacement. The genotypes of VKORC1 and CYP2C9 were determined by melting curve analysis after PCR. They were divided randomly into the study and control groups. In the study group, the first three doses of warfarin were prescribed according to the predicted warfarin maintenance dose while warfarin was initiated at 2.5 mg/d in the control group. The warfarin doses were adjusted according to the measured international normalized ratio (INR) values. And all subjects were followed for 50 days after an initiation of warfarin therapy. At the end of a 50-day follow-up period, the proportions of the patients on a stable dose were 82.4% (42/51) and 62.5% (30/48) for the study and control groups respectively. The mean durations of reaching a stable dose of warfarin were (27.5 ± 1.8) and (34.7 ± 1.8) days and the median durations were (24.0 ± 1.7) and (33.0 ± 4.5) days in the study and control groups respectively. Significant differences existed in the durations of reaching a stable dose between the two groups (P = 0.012). Compared with the control group, the hazard ratio (HR) for the duration of reaching a stable dose was 1.786 in the study group (95%CI 1.088 - 2.875, P = 0.026). The predicted dosing algorithm incorporating genetic and non-genetic factors may shorten the duration of achieving efficiently a stable dose of warfarin. And the present study validates the feasibility of its clinical application.

  14. External dose-rate conversion factors for calculation of dose to the public

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    This report presents a tabulation of dose-rate conversion factors for external exposure to photons and electrons emitted by radionuclides in the environment. This report was prepared in conjunction with criteria for limiting dose equivalents to members of the public from operations of the US Department of Energy (DOE). The dose-rate conversion factors are provided for use by the DOE and its contractors in performing calculations of external dose equivalents to members of the public. The dose-rate conversion factors for external exposure to photons and electrons presented in this report are based on a methodology developed at Oak Ridge National Laboratory. However, some adjustments of the previously documented methodology have been made in obtaining the dose-rate conversion factors in this report. 42 refs., 1 fig., 4 tabs.

  15. Enjebi Island dose assessment

    International Nuclear Information System (INIS)

    Robison, W.L.; Conrado, C.L.; Phillips, W.A.

    1987-07-01

    We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and 137 Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body dose equivalents are 3.5 rem, 5.1 rem, and 6.2 rem, respectively. Bone-marrow dose equivalents are only slightly higher than the whole-body estimates in each case. The bone-surface cells (endosteal cells) receive the highest dose, but they are a less sensitive cell population and are less sensitive to fatal cancer induction than whole body and bone marrow. The effective dose equivalents for 30, 50, and 70 y are 3.6 rem, 5.3 rem, and 6.6 rem, respectively. 79 refs., 17 figs., 24 tabs

  16. Trends in doses to radiation workers recorded on the Central Index of Dose Information

    International Nuclear Information System (INIS)

    Greenslade, E.; Kendall, G.M.; Fillary, K.; Bines, W.P.

    1991-01-01

    This paper presents a preliminary analysis of the doses stored on the Central Index of Dose Information for the calendar years 1986, 1987 and 1988. Mean doses are low, and both mean doses and the proportion of workers exceeding 15 mSv in a year are decreasing with time. Underground miners are the occupational group receiving the highest doses, though in this and other relatively high dose groups the exposures are falling with time. Only 6% of workers are female and their average individual dose is about half that of men. Patterns of employment are different for women and men but there is a tendency for women to receive lower doses than men even within the same occupation. (author)

  17. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  18. Dose concentration and dose verification for radiotherapy of cancer

    International Nuclear Information System (INIS)

    Maruyama, Koichi

    2005-01-01

    The number of cancer treatments using radiation therapy is increasing. The background of this increase is the accumulated fact that the number of successful cases is comparative to or even better than surgery for some types of cancer due to the improvement in irradiation technology and radiation planning technology. This review describes the principles and technology of radiation therapy, its characteristics, particle therapy that improves the dose concentration, its historical background, the importance of dose concentration, present situation and future possibilities. There are serious problems that hinder the superior dose concentration of particle therapy. Recent programs and our efforts to solve these problems are described. A new concept is required to satisfy the notion of evidence based medicine, i.e., one has to develop a method of dose verification, which is not yet available. This review is for researchers, medical doctors and radiation technologists who are developing this field. (author)

  19. Augmentation of natural cytotoxicity by chronic low-dose ionizing radiation in murine natural killer cells primed by IL-2

    International Nuclear Information System (INIS)

    Sonn, Chung-Hee; Choi, Jong-Rip; Kim, Tae-Jin

    2012-01-01

    The possible beneficial effects of chronic low-dose irradiation (LDR) and its mechanism of action in a variety of pathophysiological processes such as cancer are a subject of intense investigation. While animal studies involving long-term exposure to LDR have yielded encouraging results, the influence of LDR at the cellular level has been less well defined. We reasoned that since natural killer (NK) cells constitute an early responder to exogenous stress, NK cells may reveal sentinel alterations in function upon exposure to LDR. When purified NK cells received LDR at 4.2 mGy/h for a total of 0.2 Gy in vitro, no significant difference in cell viability was observed. Likewise, no functional changes were detected in LDR-exposed NK cells, demonstrating that LDR alone was insufficient to generate changes at the cellular level. Nonetheless, significant augmentation of cytotoxic, but not proliferative, function was detected when NK cells were stimulated with low-dose IL-2 prior to irradiation. This enhancement of NK cytotoxicity was not due to alterations in NK-activating receptors, NK1.1, NKG2D, CD69 and 2B4, or changes in the rate of early or late apoptosis. Therefore, LDR, in the presence of suboptimal cytokine levels, can facilitate anti-tumor cytotoxicity of NK cells without influencing cellular proliferation or apoptosis. Whether these results translate to in vivo consequences remains to be seen; however, our data provide initial evidence that exposure to LDR can lead to subtle immune-enhancing effects on NK cells and may explain, in part, the functional basis underlying, diverse beneficial effects seen in the animals chronically exposed to LDR. (author)

  20. Absorbed dose to mice in prolonged irradiation by low-dose rate ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Shiragai, Akihiro [National Inst. of Radiological Sciences, Chiba (Japan); Saitou, Mikio; Kudo, Iwao [and others

    2000-07-01

    In this paper, the dose absorbed by mice was evaluated as a preliminary study of the late effects of prolonged continuous irradiation of mice with low-dose rate ionizing radiation. Eight-week-old male and female SPF C3H/HeN mice in three irradiation rooms were exposed to irradiation at 8000, 400, and 20 mGy, respectively, using a {sup 137}Cs {gamma}-source. Nine racks were arranged in a circle approximately 2.5 m from the source in each room, and 10 cages were arranged on the 4 shelves of each rack. Dose distributions, such as in air at the source level, in the three rooms were estimated by using ionization chambers, and the absorbed dose distributions in the room and relative dose distributions in the cages in relation to the distance of the cage center were examined. The mean abdomen doses of the mice measured by TLD were compared with the absorbed doses in the cages. The absorbed dose distributions showed not only inverse-inverse-square-law behavior with distance from the source, but geometric symmetry in every room. The inherent scattering and absorption in each room are responsible for such behavior and asymmetry. Comparison of relative dose distributions revealed cage positions that are not suitable for experiments with high precision doses, but all positions can be used for prolonged continuous irradiation experiments if the position of the cages is rotated regularly. The mean abdomen doses of the mice were similar in each cage. The mean abdomen doses of the mice and the absorbed doses in a cage were almost the same in all cages. Except for errors concerning the positions of the racks and cages, the uncertainties in the exposure doses were estimated to be about {+-}12% for 8000 mGy group, 17% for 400 mGy group, and 35% for 20 mGy group. (K.H.)

  1. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

    International Nuclear Information System (INIS)

    Fonseca, Gabriel Paiva; Yoriyaz, Hélio; Tedgren, Åsa Carlsson; Nilsson, Josef; Persson, Maria; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Dose calculation in high dose rate brachytherapy with 192 Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (D m,m ) and dose-to-water-in-medium (D w,m ). The relation between D m,m and D w,m for 192 Ir is the main goal of this study, in particular the dependence of D w,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: D m,m, D w,m (LCT), mean photon energy and photon fluence. D w,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between D m,m and D w,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between D w,m (SCT) and D w,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between D m,m and D w,m (SCT) mainly depend on tissue type, differences between D m,m and D w,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources. (paper)

  2. Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Nishizawa, Kanae; Kumamoto, Yoshikazu; Iwai, Kazuo; Mase, Naomichi.

    1993-01-01

    Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and with data from ICRP publications. The annual collective effective dose equivalent were estimated to be about 21.94 person·Sv for medical workers, 7.73 person·Sv for industrial workers, 0.75 person·Sv for research and educational workers, 2.48 person·Sv for atomic energy industry and 84.4 person ·Sv for workers in nuclear power station. The population doses were calculated to be about 1.07 Sv for genetically significant dose, 0.89 Sv for leukemia significant dose and 0.42 Sv for malignant significant dose. The population risks were estimated using these population doses. (author)

  3. Radiation doses during chest examinations using dose modulation techniques in multislice CT scanner

    International Nuclear Information System (INIS)

    Livingstone, Roshan S.; Pradip, Joe; Dinakran, Paul M.; Srikanth, B.

    2010-01-01

    Objectives: To evaluate the radiation dose and image quality using a manual protocol and dose modulation techniques in a 6-slice CT scanner. Materials and Methods: Two hundred and twenty-one patients who underwent contrast-enhanced CT of the chest were included in the study. For the manual protocol settings, constant tube potential (kV) and tube current-time product (mAs) of 140 kV and 120 mAs, respectively, were used. The angular and z-axis dose modulation techniques utilized a constant tube potential of 140 kV; mAs values were automatically selected by the machine. Effective doses were calculated using dose-length product (DLP) values and the image quality was assessed using the signal-to-noise (SNR) ratio values. Mean effective doses using manual protocol for patients of weights 40-60 kg, 61-80 kg, and 81 kg and above were 8.58 mSv, 8.54 mSv, and 9.07 mSv, respectively. Mean effective doses using z-axis dose modulation for patients of weights 40-60 kg, 61-80 kg, and 81 kg and above were 4.95 mSv, 6.87 mSv, and 10.24 mSv, respectively. The SNR at the region of the liver for patients of body weight of 40-60 kg was 5.1 H, 6.2 H, and 8.8 H for manual, angular, and z-axis dose modulation, respectively. Conclusion: Dose reduction of up to 15% was achieved using angular dose modulation and of up to 42% using z-axis dose modulation, with acceptable diagnostic image quality compared to the manual protocol. (author)

  4. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    SA JOURNAL OF RADIOLOGY • August 2004. Abstract. This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from ...

  5. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional ...

  6. Dose rate-dependent marrow toxicity of TBI in dogs and marrow sparing effect at high dose rate by dose fractionation.

    Science.gov (United States)

    Storb, R; Raff, R F; Graham, T; Appelbaum, F R; Deeg, H J; Schuening, F G; Sale, G; Seidel, K

    1999-01-01

    We evaluated the marrow toxicity of 200 and 300 cGy total-body irradiation (TBI) delivered at 10 and 60 cGy/min, respectively, in dogs not rescued by marrow transplant. Additionally, we compared toxicities after 300 cGy fractionated TBI (100 cGy fractions) to that after single-dose TBI at 10 and 60 cGy/min. Marrow toxicities were assessed on the basis of peripheral blood cell count changes and mortality from radiation-induced pancytopenia. TBI doses studied were just below the dose at which all dogs die despite optimal support. Specifically, 18 dogs were given single doses of 200 cGy TBI, delivered at either 10 (n=13) or 60 (n=5) cGy/min. Thirty-one dogs received 300 cGy TBI at 10 cGy/min, delivered as either single doses (n=21) or three fractions of 100 cGy each (n=10). Seventeen dogs were given 300 cGy TBI at 60 cGy/min, administered either as single doses (n=5) or three fractions of 100 cGy each (n=10). Within the limitations of the experimental design, three conclusions were drawn: 1) with 200 and 300 cGy single-dose TBI, an increase of dose rate from 10 to 60 cGy/min, respectively, caused significant increases in marrow toxicity; 2) at 60 cGy/min, dose fractionation resulted in a significant decrease in marrow toxicities, whereas such a protective effect was not seen at 10 cGy/min; and 3) with fractionated TBI, no significant differences in marrow toxicity were seen between dogs irradiated at 60 and 10 cGy/min. The reduced effectiveness of TBI when a dose of 300 cGy was divided into three fractions of 100 cGy or when dose rate was reduced from 60 cGy/min to 10 cGy/min was consistent with models of radiation toxicity that allow for repair of sublethal injury in DNA.

  7. Gonad dose in cineurethrocystography

    International Nuclear Information System (INIS)

    Ardran, G.M.; Dixon-Brown, A.; Fursdon, P.S.

    1978-01-01

    The technical factors used for cineurethrocystography for the true lateral projection in females are given. The mid-line radiation dose has been measured with LiF TLD inserted into the vagina in 19 examinations. The average dose recorded was 148 mrad, the range being 50 to 306 mrad, the average number of cine frames exposed was 96. Data obtained using a Rando phantom indicated that the average ovary dose would be 30% greater than the mid-line dose since the near ovary receives a higher dose than the more distant one. The technique used for men is also given, the average gonad dose in six men being 123 mrad, range 56 to 243 mrad when simple lead foil gonad protection was used; the average number of cine frames was 107. The dose in one man without gonad protection was 1575 mrad for 112 cine frames. The results for both sexes compare favourably with those of others reported in the literature and with gonad doses recorded in typical IVP examinations. (author)

  8. Dose rate and dose fractionation studies in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.

    1979-01-01

    Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients

  9. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  10. Dose and Dose-Rate Effectiveness Factor (DDREF); Der Dosis- und Dosisleistungs-Effektivitaetsfaktor (DDREF)

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, Joachim [Fachhochschule Giessen-Friedberg, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2016-08-01

    For practical radiation protection purposes it is supposed that stochastic radiation effects a determined by a proportional dose relation (LNT). Radiobiological and radiation epidemiological studies indicated that in the low dose range a dependence on dose rates might exist. This would trigger an overestimation of radiation risks based on the LNT model. OCRP had recommended a concept to combine all effects in a single factor DDREF (dose and dose-Rate effectiveness factor). There is still too low information on cellular mechanisms of low dose irradiation including possible repair and other processes. The Strahlenschutzkommission cannot identify a sufficient scientific justification for DDREF and recommends an adaption to the actual state of science.

  11. Epidemiological methods for assessing dose-response and dose-effect relationships

    DEFF Research Database (Denmark)

    Kjellström, Tord; Grandjean, Philippe

    2007-01-01

    Selected Molecular Mechanisms of Metal Toxicity and Carcinogenicity General Considerations of Dose-Effect and Dose-Response Relationships Interactions in Metal Toxicology Epidemiological Methods for Assessing Dose-Response and Dose-Effect Relationships Essential Metals: Assessing Risks from Deficiency......Description Handbook of the Toxicology of Metals is the standard reference work for physicians, toxicologists and engineers in the field of environmental and occupational health. This new edition is a comprehensive review of the effects on biological systems from metallic elements...... access to a broad range of basic toxicological data and also gives a general introduction to the toxicology of metallic compounds. Audience Toxicologists, physicians, and engineers in the fields of environmental and occupational health as well as libraries in these disciplines. Will also be a useful...

  12. A graphical review of radiogenic animal cancer data using the 'dose and dose-rate map'

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Hoshi, Yuko; Sakai, Kazuo

    2008-01-01

    We have been investigating the effects of low dose or low dose rate irradiation on mice, using our low dose-rate irradiation facilities. In these studies, we found that the effects were highly dependent on both total dose and dose rate. To show this visually, we proposed the 'dose/dose rate map', and plotted the results of our laboratory and our co-workers. The map demonstrated that dose/dose rate plane could be divided into three areas; 1) An area where harmful effects are observed, 2) An area where no harmful effects are observed, and 3) Another area, between previous two areas, where certain protective functions are enhanced. As this map would be a powerful tool to find some trend among the vast numbers of data relating the biological effects of ionizing radiation, we have developed a computer program which plots the collected data on the dose/dose rate map sorting by experimental conditions. In this study, we graphically reviewed and analyzed the data relating to the lifespan studies of animals with a view to determining the relationships between doses and dose rates of ionizing radiation and cancer incidence. The data contains about 800 sets of experiments, which concerns 187,000 animals exposed to gamma ray or X-ray and their 112,000 controls, and total of about 30,000 cancers in exposed animals and 14,000 cancers in controls. About 800 points of data were plotted on the dose/dose rate map. The plot showed that 1) The divided three areas in the dose/dose rate map were generally confirmed by these 800 points of data, and 2) In some particular conditions, e.g. sarcoma by X-rays, the biologically effective area is extended to relatively high dose/dose rate area. (author)

  13. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    Science.gov (United States)

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  14. Estimation of population doses from diagnostic medical examinations in Japan, 1974. III. Per caput mean marrow dose and leukemia significant dose

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, T; Maruyama, T; Kumamoto, Y [National Inst. of Radiological Sciences, Chiba (Japan)

    1976-03-01

    The mean per capita marrow dose and leukemia-significant dose from radiographic and fluoroscopic examinations in Japan have been estimated based on a 1974 nation wide survey of randomly sampled hospitals and clinics. To determine the mean marrow dose to an individual from a certain exposure of a given type of examination, the active marrow in the whole body was divided into 119 parts for an adult and 103 for a child. Dosimetric points on which the individual marrow doses were determined were set up in the center of each marrow part. The individual marrow doses at the dosimetric points in the beams of practical diagnostic x-rays were calculated on the basis of the exposure data on the patients selected in the nation wide survey, using depth dose curves experimentally determined for diagnostic x-rays. The mean individual marrow dose was averaged over the active marrow by summing, for each dosimetric point, the product of the fraction of active marrow exposed and the individual marrow dose at the dosimetric point. The leukemia significant dose was calculated by adopting a weighting factor that is, a leukemia significant factor. The factor was determined from the shape of the time-incidence curve for radiation-induced leukemia from the Hiroshima A-bomb and from the survival statistics for the average population. The resultant mean per capita marrow dose from radiographic and fluoroscopic examination was 37.0 and 70.0 mrad/person/year, respectively, with a total of 107.05 mrad/person/year. The leukemia significant dose was 32.1 mrad/person/year for radiographic examination and 61.2 mrad/person/year, with a total of 93.3. These values were compared with those of 1960 and 1969.

  15. Total dose meter development

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1986-09-01

    This report describes an alarming ''pocket'' monitor/dosimeter, based on a tissue-equivalent proportional counter, that measure both neutron and gamma dose and determines dose equivalent for the mixed radiation field. This report details the operation of the device and provides information on: the necessity for a device to measure dose equivalent in mixed radiation fields; the mathematical theory required to determine dose equivalent from tissue equivalent proportional; the detailed electronic circuits required; the algorithms required in the microprocessor used to calculate dose equivalent; the features of the instrument; program accomplishments and future plans

  16. Parotid gland mean dose as a xerostomia predictor in low-dose domains.

    Science.gov (United States)

    Gabryś, Hubert Szymon; Buettner, Florian; Sterzing, Florian; Hauswald, Henrik; Bangert, Mark

    2017-09-01

    Xerostomia is a common side effect of radiotherapy resulting from excessive irradiation of salivary glands. Typically, xerostomia is modeled by the mean dose-response characteristic of parotid glands and prevented by mean dose constraints to either contralateral or both parotid glands. The aim of this study was to investigate whether normal tissue complication probability (NTCP) models based on the mean radiation dose to parotid glands are suitable for the prediction of xerostomia in a highly conformal low-dose regime of modern intensity-modulated radiotherapy (IMRT) techniques. We present a retrospective analysis of 153 head and neck cancer patients treated with radiotherapy. The Lyman Kutcher Burman (LKB) model was used to evaluate predictive power of the parotid gland mean dose with respect to xerostomia at 6 and 12 months after the treatment. The predictive performance of the model was evaluated by receiver operating characteristic (ROC) curves and precision-recall (PR) curves. Average mean doses to ipsilateral and contralateral parotid glands were 25.4 Gy and 18.7 Gy, respectively. QUANTEC constraints were met in 74% of patients. Mild to severe (G1+) xerostomia prevalence at both 6 and 12 months was 67%. Moderate to severe (G2+) xerostomia prevalence at 6 and 12 months was 20% and 15%, respectively. G1 + xerostomia was predicted reasonably well with area under the ROC curve ranging from 0.69 to 0.76. The LKB model failed to provide reliable G2 + xerostomia predictions at both time points. Reduction of the mean dose to parotid glands below QUANTEC guidelines resulted in low G2 + xerostomia rates. In this dose domain, the mean dose models predicted G1 + xerostomia fairly well, however, failed to recognize patients at risk of G2 + xerostomia. There is a need for the development of more flexible models able to capture complexity of dose response in this dose regime.

  17. Pocket total dose meter

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.

    1984-10-01

    Laboratory measurements have demonstrated that it is possible to simultaneously measure absorbed dose and dose equivalent using a single tissue equivalent proportional counter. Small, pocket sized instruments are being developed to determine dose equivalent as the worker is exposed to mixed field radiation. This paper describes the electronic circuitry and computer algorithms used to determine dose equivalent in these devices

  18. The combination of IL-21 and IFN-alpha boosts STAT3 activation, cytotoxicity and experimental tumor therapy

    DEFF Research Database (Denmark)

    Eriksen, Karsten W; Søndergaard, Henrik; Woetmann, Anders

    2008-01-01

    such as IFN-alpha and IL-2 have multiple and severe side effects. Accordingly, they are generally used at sub-optimal doses, which limit their clinical efficacy. Here we hypothesized that a combination of IFN-alpha and IL-21, a novel cytokine of the IL-2 family with anti-cancer effects, will increase the anti......-cancer efficacy at sub-optimal cytokine doses. We show that the combined stimulation of target-cells with IFN-alpha and IL-21 triggers an increased STAT3 activation whereas the activation of other STATs including STAT1/2 is unaffected. In parallel, the combined stimulation with IFN-alpha and IL-21 triggers...... a selective increase in MHC class I expression and NK- and CD8(+) T-cell-mediated cytotoxicity. In an experimental in vivo model of renal carcinoma, the combined treatment of IFN-alpha and IL-21 also produces a significant anti-cancer effect as judged by an inhibition of tumor growth and an increased survival...

  19. Equivalent dose determination in foraminifera: analytical description of the CO2--signal dose-response curve

    International Nuclear Information System (INIS)

    Hoffmann, D.; Woda, C.; Mangini, A.

    2003-01-01

    The dose-response of the CO 2 - signal (g=2.0006) in foraminifera with ages between 19 and 300 ka is investigated. The sum of two exponential saturation functions is an adequate function to describe the dose-response curve up to an additional dose of 8000 Gy. It yields excellent dating results but requires an artificial doses of at least 5000 Gy. For small additional doses of about 500 Gy the single exponential saturation function can be used to calculate a reliable equivalent dose D E , although it does not describ the dose-response for higher doses. The CO 2 - -signal dose-response indicates that the signal has two components of which one is less stable than the other

  20. Late effects of low doses and dose rates

    International Nuclear Information System (INIS)

    Paretzke, H.G.

    1980-01-01

    This paper outlines the spectrum of problems and approaches used in work on the derivation of quantitative prognoses of late effects in man of low doses and dose rates. The origins of principal problems encountered in radiation risks assessments, definitions and explanations of useful quantities, methods of deriving risk factors from biological and epidemiological data, and concepts of risk evaluation and problems of acceptance are individually discussed

  1. Plutonium dose-effect relationship

    International Nuclear Information System (INIS)

    Matsuoka, Osamu

    1976-01-01

    Dose in internal exposure to Pu was investigated, and dose-effect relationship was discussed. Dose-effect relationship in internal exposure was investigated by means of two methods, which were relationship between dose and its effect (relationship between μ Ci/Kg and its effect), and exposure dose and its effects (rad-effect), and merits and demerits of two methods were mentioned. Problems in a indication method such as mean dose were discussed with respect to the dose in skeleton, the liver and the lung. Pu-induced osteosarcoma in mice rats, and beagles was described, and differences in its induction between animals were discussed. Pulmonary neoplasma induced by 239 PuO 2 inhalation in beagles was reported, and description was made as to differences in induction of lung cancer between animals when Pu was inhaled and was taken into the lung. A theoretical and experimental study of a extrapolation of the results of the animal experiment using Pu to human cases is necessary. (Serizawa, K.)

  2. A trial of radiation dose prescription based on dose-cell survival formula

    International Nuclear Information System (INIS)

    Allen, E.P.

    1984-01-01

    Radiation treatment has been prescribed for 379 basal cell carcinomata on the basis of a selected equivalent single dose derived from the standard multi-target dose-cell survival formula using values of m = 2 and Do = 130 rads for orthovoltage x-rays. The results suggest that the approach provides a flexible and acceptable alternative to prescription by total dose or by Nominal Standard Dose. It is submitted that Total Dose is an inadequate expression of radiobiological effects: that the NSD and related systems are valuable measures of the ability of normal tissues to recover from radiation damage: and that a parallel measure of the degree of tumour depopulation has become necessary to allow further progress in alternative fractionation schedules

  3. SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mashouf, S; Merino, T; Ravi, A; Morton, G; Song, W [Sunnybrook Health Sciences Center, Odette Cancer Centre, Toronto, ON (Canada); University of Toronto, Dept. of Radiation Oncology, Toronto, ON (Canada); Safigholi, H; Soliman, A [Sunnybrook Research Institute, Toronto, ON (Canada)

    2016-06-15

    Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.

  4. SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

    International Nuclear Information System (INIS)

    Mashouf, S; Merino, T; Ravi, A; Morton, G; Song, W; Safigholi, H; Soliman, A

    2016-01-01

    Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.

  5. Optimizing Radiation Doses for Computed Tomography Across Institutions: Dose Auditing and Best Practices.

    Science.gov (United States)

    Demb, Joshua; Chu, Philip; Nelson, Thomas; Hall, David; Seibert, Anthony; Lamba, Ramit; Boone, John; Krishnam, Mayil; Cagnon, Christopher; Bostani, Maryam; Gould, Robert; Miglioretti, Diana; Smith-Bindman, Rebecca

    2017-06-01

    Radiation doses for computed tomography (CT) vary substantially across institutions. To assess the impact of institutional-level audit and collaborative efforts to share best practices on CT radiation doses across 5 University of California (UC) medical centers. In this before/after interventional study, we prospectively collected radiation dose metrics on all diagnostic CT examinations performed between October 1, 2013, and December 31, 2014, at 5 medical centers. Using data from January to March (baseline), we created audit reports detailing the distribution of radiation dose metrics for chest, abdomen, and head CT scans. In April, we shared reports with the medical centers and invited radiology professionals from the centers to a 1.5-day in-person meeting to review reports and share best practices. We calculated changes in mean effective dose 12 weeks before and after the audits and meeting, excluding a 12-week implementation period when medical centers could make changes. We compared proportions of examinations exceeding previously published benchmarks at baseline and following the audit and meeting, and calculated changes in proportion of examinations exceeding benchmarks. Of 158 274 diagnostic CT scans performed in the study period, 29 594 CT scans were performed in the 3 months before and 32 839 CT scans were performed 12 to 24 weeks after the audit and meeting. Reductions in mean effective dose were considerable for chest and abdomen. Mean effective dose for chest CT decreased from 13.2 to 10.7 mSv (18.9% reduction; 95% CI, 18.0%-19.8%). Reductions at individual medical centers ranged from 3.8% to 23.5%. The mean effective dose for abdominal CT decreased from 20.0 to 15.0 mSv (25.0% reduction; 95% CI, 24.3%-25.8%). Reductions at individual medical centers ranged from 10.8% to 34.7%. The number of CT scans that had an effective dose measurement that exceeded benchmarks was reduced considerably by 48% and 54% for chest and abdomen, respectively. After

  6. Effects of TCMC on Transformation of Good Health Status to Suboptimal Health Status: A Nested Case-Control Study

    Science.gov (United States)

    Wang, Tian; Chen, Jieyu; Sun, Xiaomin; Xiang, Lei; Zhou, Lin; Li, Fei; Lin, Changsong; Jiang, Pingping; Wu, Shengwei; Xiao, Ya; Cheng, Jingru; Luo, Ren; Liu, Yanyan; Zhao, Xiaoshan

    2015-01-01

    To explore the effects of traditional Chinese medicine constitution (TCMC) on transformation of good health status to suboptimal health status (SHS), we conducted a nested case-control study among college students in China. During the 18-month mean follow-up time, 543 cases of SHS (42.7%) occurred in 1273 healthy students. There was a significant (P = 0.000) and marked reduction in SHMS V1.0 total score in the case group at the 18-month follow-up (69.32 ± 5.45) compared with baseline (78.60 ± 4.70), but there was no significant change in the control group. Conditional logistic regression analysis showed that respondents reporting Yin-deficiency and Qi-deficiency were, respectively, 2.247 and 2.198 times more likely to develop SHS, while tendency to Yin-deficiency and tendency to Damp-heat were, respectively, 1.642 and 1.506 times more likely to develop SHS. However, the Balanced Constitution was a significant protective factor (OR 0.649; P < 0.05). Altogether, these findings demonstrate that Yin-deficiency, Qi-deficiency, tendency to Yin-deficiency, and tendency to Damp-heat appeared to induce a change in health status to SHS, while the Balanced Constitution seemed to restrain this change. We conclude that regulating the unbalanced TCMC (such as Yin-deficiency and Qi-deficiency) may prevent a healthy status developing into SHS or lead to the regression of SHS. PMID:26346320

  7. Effects of TCMC on Transformation of Good Health Status to Suboptimal Health Status: A Nested Case-Control Study

    Directory of Open Access Journals (Sweden)

    Tian Wang

    2015-01-01

    Full Text Available To explore the effects of traditional Chinese medicine constitution (TCMC on transformation of good health status to suboptimal health status (SHS, we conducted a nested case-control study among college students in China. During the 18-month mean follow-up time, 543 cases of SHS (42.7% occurred in 1273 healthy students. There was a significant (P=0.000 and marked reduction in SHMS V1.0 total score in the case group at the 18-month follow-up (69.32 ± 5.45 compared with baseline (78.60 ± 4.70, but there was no significant change in the control group. Conditional logistic regression analysis showed that respondents reporting Yin-deficiency and Qi-deficiency were, respectively, 2.247 and 2.198 times more likely to develop SHS, while tendency to Yin-deficiency and tendency to Damp-heat were, respectively, 1.642 and 1.506 times more likely to develop SHS. However, the Balanced Constitution was a significant protective factor (OR 0.649; P<0.05. Altogether, these findings demonstrate that Yin-deficiency, Qi-deficiency, tendency to Yin-deficiency, and tendency to Damp-heat appeared to induce a change in health status to SHS, while the Balanced Constitution seemed to restrain this change. We conclude that regulating the unbalanced TCMC (such as Yin-deficiency and Qi-deficiency may prevent a healthy status developing into SHS or lead to the regression of SHS.

  8. A study on mice exposure dose for low-dose gamma-irradiation using glass dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Sung Jin; Kim, Hyo Jin; Kim, Hyun; Jeong, Dong Hyeok; Son, Tae Gen; Kim, Jung Ki; Yang, Kwang Mo; Kang, Yeong Rok [Research Center, Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, Sang Hee [Dept. of Biomedical Engineering, Inje University, Gimhae (Korea, Republic of)

    2015-12-15

    The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using {sup 137}C{sub s} irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological and Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.

  9. Receptor dose and patient dose in radiographic exposures: a 15 year review

    International Nuclear Information System (INIS)

    Peet, D.J.; Tyler, N.; Pryor, M.; Hollaway, P.; Strudley, C.; Leavesley, L.

    2008-01-01

    A patient dose programme has been established locally for the last 15 years across 109 hospitals and 250 X-ray rooms in line with the National Protocol, in conjunction with a programme to look at routine performance of these rooms. Routine performance checks initially looked primarily at film density and AEC performance but with the introduction of Computerised Radiography (CR) across UK hospitals and a revision of recommended procedures in the UK, the emphasis has shifted to assessing receptor dose under AEC control. Results show a wide variation in film density in the early years indicating sub optimal performance and dose. The spread was reduced over later years. The introduction of CR has led to a variety of approaches by the CR companies, X-ray companies and local sites. Receptor doses vary widely as a result. Large variations within hospitals were also observed. The doses over the last 15 years are reviewed and compared against diagnostic reference levels and with the performance of the imaging chain. Results show that patient dose programmes and optimisation strategies were having an impact, but the introduction of CR requires renewed efforts to ensure images and doses are optimised. (author)

  10. Retrospective analysis of dose delivery in intra-operative high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Oh, M.; Avadhani, J.S.; Malhotra, H.K.; Cunningham, B.; Tripp, P.; Jaggernauth, W.; Podgorsak, M.B.

    2007-01-01

    Background. This study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in intra-operative high dose rate (IOHDR) brachytherapy. Methods. Treatment plans of 10 patients previously treated in our facility, which had irregular shapes of treated areas, were used. Treatment geometries reflecting each clinical case were simulated using a phantom assembly with no added build-up on top of the applicator. The treatment planning geometry (full scatter surrounding the applicator) was subsequently simulated for each case by adding bolus on top of the applicator. Results. For geometries representing the clinical IOHDR incomplete scatter environment, measured doses at the 5 mm and 10 mm prescription depths were lower than the corresponding prescribed doses by about 7.7% and 11.1%, respectively. Also, for the two prescription methods, an analysis of the measured dose distributions and their corresponding treatment plans showed average decreases of 1.2 mm and 2.2 mm in depth of prescription dose, respectively. Conclusions. Dosimetric calculations with the assumption of an infinite scatter environment around the applicator and target volume have shown to result in dose delivery errors that significantly decrease the prescription depth for IOHDR treatment.(author)

  11. Age-dependent conversion coefficients for organ doses and effective doses for external neutron irradiation

    International Nuclear Information System (INIS)

    Nishizaki, Chihiro; Endo, Akira; Takahashi, Fumiaki

    2006-06-01

    To utilize dose assessment of the public for external neutron irradiation, conversion coefficients of absorbed doses of organs and effective doses were calculated using the numerical simulation technique for six different ages (adult, 15, 10, 5 and 1 years and newborn), which represent the member of the public. Calculations were performed using six age-specific anthropomorphic phantoms and a Monte Carlo radiation transport code for two irradiation geometries, anterior-posterior and rotational geometries, for 20 incident energies from thermal to 20 MeV. Effective doses defined by the 1990 Recommendation of ICRP were calculated from the absorbed doses in 21 organs. The calculated results were tabulated in the form of absorbed doses and effective doses per unit neutron fluence. The calculated conversion coefficients are used for dose assessment of the public around nuclear facilities and accelerator facilities. (author)

  12. Low doses effects and gamma radiations low dose rates

    International Nuclear Information System (INIS)

    Averbeck, D.

    1999-01-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  13. Dose and dose rate effects of whole-body gamma-irradiation: I. Lymphocytes and lymphoid organs

    Science.gov (United States)

    Pecaut, M. J.; Nelson, G. A.; Gridley, D. S.

    2001-01-01

    The major goal of part I of this study was to compare varying doses and dose rates of whole-body gamma-radiation on lymphoid cells and organs. C57BL/6 mice (n = 75) were exposed to 0, 0.5, 1.5, and 3.0 Gy gamma-rays (60Co) at 1 cGy/min (low-dose rate, LDR) and 80 cGy/min (high-dose rate, HDR) and euthanized 4 days later. A significant dose-dependent loss of spleen mass was observed with both LDR and HDR irradiation; for the thymus this was true only with HDR. Decreasing leukocyte and lymphocyte numbers occurred with increasing dose in blood and spleen at both dose rates. The numbers (not percentages) of CD3+ T lymphocytes decreased in the blood in a dose-dependent manner at both HDR and LDR. Splenic T cell counts decreased with dose only in HDR groups; percentages increased with dose at both dose rates. Dose-dependent decreases occurred in CD4+ T helper and CD8+ T cytotoxic cell counts at HDR and LDR. In the blood the percentages of CD4+ cells increased with increasing dose at both dose rates, whereas in the spleen the counts decreased only in the HDR groups. The percentages of the CD8+ population remained stable in both blood and spleen. CD19+ B cell counts and percentages in both compartments declined markedly with increasing HDR and LDR radiation. NK1.1+ natural killer cell numbers and proportions remained relatively stable. Overall, these data indicate that the observed changes were highly dependent on the dose, but not dose rate, and that cells in the spleen are more affected by dose rate than those in blood. The results also suggest that the response of lymphocytes in different body compartments may be variable.

  14. Warfarin maintenance dose in older patients: higher average dose and wider dose frequency distribution in patients of African ancestry than those of European ancestry.

    Science.gov (United States)

    Garwood, Candice L; Clemente, Jennifer L; Ibe, George N; Kandula, Vijay A; Curtis, Kristy D; Whittaker, Peter

    2010-06-15

    Studies report that warfarin doses required to maintain therapeutic anticoagulation decrease with age; however, these studies almost exclusively enrolled patients of European ancestry. Consequently, universal application of dosing paradigms based on such evidence may be confounded because ethnicity also influences dose. Therefore, we determined if warfarin dose decreased with age in Americans of African ancestry, if older African and European ancestry patients required different doses, and if their daily dose frequency distributions differed. Our chart review examined 170 patients of African ancestry and 49 patients of European ancestry cared for in our anticoagulation clinic. We calculated the average weekly dose required for each stable, anticoagulated patient to maintain an international normalized ratio of 2.0 to 3.0, determined dose averages for groups 80 years of age and plotted dose as a function of age. The maintenance dose in patients of African ancestry decreased with age (PAfrican ancestry required higher average weekly doses than patients of European ancestry: 33% higher in the 70- to 79-year-old group (38.2+/-1.9 vs. 28.8+/-1.7 mg; P=0.006) and 52% in the >80-year-old group (33.2+/-1.7 vs. 21.8+/-3.8 mg; P=0.011). Therefore, 43% of older patients of African ancestry required daily doses >5mg and hence would have been under-dosed using current starting-dose guidelines. The dose frequency distribution was wider for older patients of African ancestry compared to those of European ancestry (PAfrican ancestry indicate that strategies for initiating warfarin therapy based on studies of patients of European ancestry could result in insufficient anticoagulation and thereby potentially increase their thromboembolism risk. Copyright 2010 Elsevier Inc. All rights reserved.

  15. Dose reader CD-02

    International Nuclear Information System (INIS)

    Jakowiuk, A.; Kaluska, I.; Machaj, B.

    2005-01-01

    Dose Reader CD-02 is designed for measurement of dose from a long narrow band of dosimetric foil used for check up and control of electron beam dose during sterilization of materials and products on conveyor belt. Irradiated foil after processing (heating) is inserted into foil driving (moving) system and when the foil is moved across focused light beam the absorbed dose is measured and displayed at the same time at computer monitor (in form of a diagram). The absorbed dose is measured on the principle of light attenuation at selected light wavelength (foil absorbance is measured). (author)

  16. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    International Nuclear Information System (INIS)

    Han, Su Chul; Hong, Dong Hee

    2016-01-01

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures

  17. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Division of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Hong, Dong Hee [Dept. of Radiology Science, Far East University, Eumseong (Korea, Republic of)

    2016-09-15

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

  18. Dose limits

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1987-12-01

    The dose limit is defined to be the level of harmfulness which must not be exceeded, so that an activity can be exercised in a regular manner without running a risk unacceptable to man and the society. The paper examines the effects of radiation categorised into stochastic and non-stochastic. Dose limits for workers and the public are discussed

  19. Low doses effects and gamma radiations low dose rates; Les effets des faibles doses et des faibles debits de doses de rayons gamma

    Energy Technology Data Exchange (ETDEWEB)

    Averbeck, D [Institut Curie, CNRS UMR 2027, 75 - Paris (France)

    1999-07-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  20. Considerations on absorbed dose estimates based on different β-dose point kernels in internal dosimetry

    International Nuclear Information System (INIS)

    Uchida, Isao; Yamada, Yasuhiko; Yamashita, Takashi; Okigaki, Shigeyasu; Oyamada, Hiyoshimaru; Ito, Akira.

    1995-01-01

    In radiotherapy with radiopharmaceuticals, more accurate estimates of the three-dimensional (3-D) distribution of absorbed dose is important in specifying the activity to be administered to patients to deliver a prescribed absorbed dose to target volumes without exceeding the toxicity limit of normal tissues in the body. A calculation algorithm for the purpose has already been developed by the authors. An accurate 3-D distribution of absorbed dose based on the algorithm is given by convolution of the 3-D dose matrix for a unit cubic voxel containing unit cumulated activity, which is obtained by transforming a dose point kernel into a 3-D cubic dose matrix, with the 3-D cumulated activity distribution given by the same voxel size. However, beta-dose point kernels affecting accurate estimates of the 3-D absorbed dose distribution have been different among the investigators. The purpose of this study is to elucidate how different beta-dose point kernels in water influence on the estimates of the absorbed dose distribution due to the dose point kernel convolution method by the authors. Computer simulations were performed using the MIRD thyroid and lung phantoms under assumption of uniform activity distribution of 32 P. Using beta-dose point kernels derived from Monte Carlo simulations (EGS-4 or ACCEPT computer code), the differences among their point kernels gave little differences for the mean and maximum absorbed dose estimates for the MIRD phantoms used. In the estimates of mean and maximum absorbed doses calculated using different cubic voxel sizes (4x4x4 mm and 8x8x8 mm) for the MIRD thyroid phantom, the maximum absorbed doses for the 4x4x4 mm-voxel were estimated approximately 7% greater than the cases of the 8x8x8 mm-voxel. They were found in every beta-dose point kernel used in this study. On the other hand, the percentage difference of the mean absorbed doses in the both voxel sizes for each beta-dose point kernel was less than approximately 0.6%. (author)

  1. Analysis of CT radiation dose based on radiation-dose-structured reports

    International Nuclear Information System (INIS)

    Wang Weipeng; Zhang Yi; Zhang Menglong; Zhang Dapeng; Song Shaojuan

    2014-01-01

    Objective: To analyse the CT radiation dose statistically using the standardized radiation-dose-structured report (RDSR) of digital imaging and communications in medicine (DICOM). Methods: Using the self-designed software, 1230 RDSR files about CT examination were obtained searching on the picture archiving and communication system (PACS). The patient dose database was established by combination of the extracted relevant information with the scanned sites. The patients were divided into adult group (over 10 years) and child groups (0-1 year, 1-5 years, 5-10 years) according to the age. The average volume CT dose index (CTDI vol ) and dose length product (DLP) of all scans were recorded respectively, and then the effective dose (E) was estimated. The DLP value at 75% quantile was calculated and compared with the diagnostic reference level (DRL). Results: In adult group, CTDI vol and DLP values were moderately and positively correlated (r = 0.41), the highest E was observed in upper abdominal enhanced scan, and the DLP value at 75% quantile was 60% higher than DRL. In child group, their CTDI vol in group of 5-10 years was greater than that in groups of 0-1 and 1-5 years (t = 2.42, 2.04, P < 0.05); the DLP value was slightly and positively correlated with the age (r = 0.16), while E was moderately and negatively correlated with the age (r = -0.48). Conclusions: It is a simple and efficient method to use RDSR to obtain the radiation doses of patients. With the popularization of the new equipment and the application of regionalized medical platform, RDSR would become the main tool for the dosimetric level surveying and individual dose recording. (authors)

  2. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  3. Intercomparison On Depth Dose Measurement

    International Nuclear Information System (INIS)

    Rohmah, N; Akhadi, M

    1996-01-01

    Intercomparation on personal dose evaluation system has been carried out between CSRSR-NAEA of Indonesia toward Standard Laboratory of JAERI (Japan) and ARL (Australia). The intercomparison was in 10 amm depth dose measurement , Hp (10), from the intercomparison result could be stated that personal depth dose measurement conducted by CSRSR was sufficiently good. Deviation of dose measurement result using personal dosemeter of TLD BG-1 type which were used by CSRSR in the intercomparison and routine photon personal dose monitoring was still in internationally agreed limit. Maximum deviation of reported doses by CSRSR compared to delivered doses for dosemeter irradiation by JAERI was -10.0 percent and by ARL was +29 percent. Maximum deviation permitted in personal dose monitoring is ± 50 percent

  4. Application of a Novel Dose-Uncertainty Model for Dose-Uncertainty Analysis in Prostate Intensity-Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Jin Hosang; Palta, Jatinder R.; Kim, You-Hyun; Kim, Siyong

    2010-01-01

    Purpose: To analyze dose uncertainty using a previously published dose-uncertainty model, and to assess potential dosimetric risks existing in prostate intensity-modulated radiotherapy (IMRT). Methods and Materials: The dose-uncertainty model provides a three-dimensional (3D) dose-uncertainty distribution in a given confidence level. For 8 retrospectively selected patients, dose-uncertainty maps were constructed using the dose-uncertainty model at the 95% CL. In addition to uncertainties inherent to the radiation treatment planning system, four scenarios of spatial errors were considered: machine only (S1), S1 + intrafraction, S1 + interfraction, and S1 + both intrafraction and interfraction errors. To evaluate the potential risks of the IMRT plans, three dose-uncertainty-based plan evaluation tools were introduced: confidence-weighted dose-volume histogram, confidence-weighted dose distribution, and dose-uncertainty-volume histogram. Results: Dose uncertainty caused by interfraction setup error was more significant than that of intrafraction motion error. The maximum dose uncertainty (95% confidence) of the clinical target volume (CTV) was smaller than 5% of the prescribed dose in all but two cases (13.9% and 10.2%). The dose uncertainty for 95% of the CTV volume ranged from 1.3% to 2.9% of the prescribed dose. Conclusions: The dose uncertainty in prostate IMRT could be evaluated using the dose-uncertainty model. Prostate IMRT plans satisfying the same plan objectives could generate a significantly different dose uncertainty because a complex interplay of many uncertainty sources. The uncertainty-based plan evaluation contributes to generating reliable and error-resistant treatment plans.

  5. Dose reduction in evacuation proctography

    International Nuclear Information System (INIS)

    Hare, C.; Halligan, S.; Bartram, C.I.; Gupta, R.; Walker, A.E.; Renfrew, I.

    2001-01-01

    The goal of this study was to reduce the patient radiation dose from evacuation proctography. Ninety-eight consecutive adult patients referred for proctography to investigate difficult rectal evacuation were studied using a digital imaging system with either a standard digital program for barium examinations, a reduced dose digital program (both with and without additional copper filtration), or Video fluoroscopy. Dose-area products were recorded for each examination and the groups were compared. All four protocols produced technically acceptable examinations. The low-dose program with copper filtration (median dose 382 cGy cm 2 ) and Video fluoroscopy (median dose 705 cGy cm 2 ) were associated with significantly less dose than other groups (p < 0.0001). Patient dose during evacuation proctography can be reduced significantly without compromising the diagnostic quality of the examination. A digital program with added copper filtration conveyed the lowest dose. (orig.)

  6. MONTEC, an interactive fortran program to simulate radiation dose and dose-rate responses of populations

    International Nuclear Information System (INIS)

    Perry, K.A.; Szekely, J.G.

    1983-09-01

    The computer program MONTEC was written to simulate the distribution of responses in a population whose members are exposed to multiple radiation doses at variable dose rates. These doses and dose rates are randomly selected from lognormal distributions. The individual radiation responses are calculated from three equations, which include dose and dose-rate terms. Other response-dose/rate relationships or distributions can be incorporated by the user as the need arises. The purpose of this documentation is to provide a complete operating manual for the program. This version is written in FORTRAN-10 for the DEC system PDP-10

  7. Radiobiological aspects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation

    International Nuclear Information System (INIS)

    Turesson, I.

    1990-01-01

    The biological effects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation in interstitial and intracavitary radiotherapy and total body irradiation are discussed in terms of dose-rate fractionation sensitivity for various tissues. A scaling between dose-rate and fraction size was established for acute and late normal-tissue effects which can serve as a guideline for local treatment in the range of dose rates between 0.02 and 0.005 Gy/min and fraction sizes between 8.5 and 2.5 Gy. This is valid provided cell-cycle progression and proliferation can be ignored. Assuming that the acute and late tissue responses are characterized by α/β values of about 10 and 3 Gy and a mono-exponential repair half-time of about 3 h, the same total doses given with either of the two methods are approximately equivalent. The equivalence for acute and late non-hemopoietic normal tissue damage is 0.02 Gy/min and 8.5 Gy per fraction; 0.01 Gy/min and 5.5 Gy per fraction; and 0.005 Gy/min and 2.5Gy per fraction. A very low dose rate, below 0.005 Gy/min, is thus necessary to simulate high dose-rate radiotherapy with fraction sizes of about 2Gy. The scaling factor is, however, dependent on the repair half-time of the tissue. A review of published data on dose-rate effects for normal tissue response showed a significantly stronger dose-rate dependence for late than for acute effects below 0.02 Gy/min. There was no significant difference in dose-rate dependence between various acute non-hemopoietic effects or between various late effects. The consistent dose-rate dependence, which justifies the use of a general scaling factor between fraction size and dose rate, contrasts with the wide range of values for repair half-time calculated for various normal-tissue effects. This indicates that the model currently used for repair kinetics is not satisfactory. There are also few experimental data in the clinical dose-rate range, below 0.02 Gy/min. It is therefore

  8. Biological effects of low doses of radiation at low dose rate

    International Nuclear Information System (INIS)

    1996-05-01

    The purpose of this report was to examine available scientific data and models relevant to the hypothesis that induction of genetic changes and cancers by low doses of ionizing radiation at low dose rate is a stochastic process with no threshold or apparent threshold. Assessment of the effects of higher doses of radiation is based on a wealth of data from both humans and other organisms. 234 refs., 26 figs., 14 tabs

  9. Radiation doses in interventional neuroradiology

    International Nuclear Information System (INIS)

    Theodorakou, C.; Butler, P.; Horrocks, J.A.

    2001-01-01

    Patient radiation doses during interventional radiology (IR) procedures may reach the thresholds for radiation-induced skin and eye lens injuries. This study investigates the radiation doses received by patients undergoing cerebral embolization. Measurements were conducted using thermoluminescent dosimeters. Radiotherapy verification films were used in order to visualise the radiation field. For each procedure the fluoroscopic and digital dose-area product, the fluoroscopic time, the total number of acquired images and entrance-skin dose calculated by the angiographic unit were recorded. In this paper, the skin, eye and thyroid glands doses on a sample of patients are presented. From a preliminary study of 13 patients having undergone cerebral embolization, it was deduced that six of them have received a dose above 1 Gy. Detailed dose data from patients undergoing IR procedures will be collected in the future with the aim of developing a model to allow estimation of the dose prior to the procedure as well as to look at techniques of dose reduction. (author)

  10. Correlation of patient maximum skin doses in cardiac procedures with various dose indicators

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.; Werduch, A.; Religa, W.

    2008-01-01

    In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7-27.3) min, (16-317) Gy cm 2 and (43-1507) mGy, respectively, and for interventions, accordingly (2.1-43.6) min, (17-425) Gy cm 2 , (71-1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295-4689) mGy and (121-1768) mGy and for PCI (267-6524) mGy and (68-2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities. (authors)

  11. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1997-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume -- Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) -- Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  12. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1996-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume --Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) --Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  13. A comparison of the angular dependence of effective dose and effective dose equivalent

    International Nuclear Information System (INIS)

    Sitek, M.A.; Gierga, D.P.; Xu, X.G.

    1996-01-01

    In ICRP (International Commission on Radiological Protection) Publication 60, the set of critical organs and their weighing factors were changed, defining the quantity effective dose, E. This quantity replaced the effective dose equivalent, H E , as defined by ICRP 26. Most notably, the esophagus was added to the list of critical organs. The Monte Carlo neutron/photon transport code MCNP was used to determine the effective dose to sex-specific anthropomorphic phantoms. The phantoms, developed in previous research, were modified to include the esophagus. Monte Carlo simulations were performed for monoenergetic photon beams of energies 0.08 MeV, 0.3 MeV, and 1.0 MeV for various azimuthal and polar angles. Separate organ equivalent doses were determined for male and female phantoms. The resulting organ equivalent doses were calculated from arithmetic mean averages. The angular dependence of effective dose was compared with that of effective dose equivalent reported in previous research. The differences between the two definitions and possible implications to regulatory agencies were summarized

  14. Importance of the Computed Tomography Dose Index (CTDI) and Dose Length Product (DLP)

    International Nuclear Information System (INIS)

    Rasolomboahanginjatovo, L.M.

    2014-01-01

    This work is under the auspice of the International Atomic Energy Agency (IAEA) projects (RAF/9/053) untitled S trengthening of the technical capacity for the protection patients and worker . The goal of this work is to highlight the importance of the Computed Tomography Dose Index (CTDI) and the Dose Length product (DLP). Measures were done at Polyclinic of Ilafy and CRDT Anosivavaka, Antananarivo, Madagascar. Doses were evaluated by use of pencil ionization chamber model 6000-10 connected with an electrometer RAD-CHECK model 06-256. Knowledge of dose indicator and Diagnostic Reference Level (DRL) allow the monitoring of scanner within the appropriate average dosimeter. It also insures the progressive determination for the most adapted dose requirements by choice of parameters available on scanner device. Measurements confirmed that doses from scanner devices of the two centers were under DRL requirements proposed by the IAEA, the European Commission (EC) and the National Radiological Protection Board (NRPB). The present results confirm that the patient delivered doses for the two centers are optimized. [fr

  15. Integral dose conservation in radiotherapy

    International Nuclear Information System (INIS)

    Reese, Adam S.; Das, Shiva K.; Curle, Charles; Marks, Lawrence B.

    2009-01-01

    Treatment planners frequently modify beam arrangements and use IMRT to improve target dose coverage while satisfying dose constraints on normal tissues. The authors herein analyze the limitations of these strategies and quantitatively assess the extent to which dose can be redistributed within the patient volume. Specifically, the authors hypothesize that (1) the normalized integral dose is constant across concentric shells of normal tissue surrounding the target (normalized to the average integral shell dose), (2) the normalized integral shell dose is constant across plans with different numbers and orientations of beams, and (3) the normalized integral shell dose is constant across plans when reducing the dose to a critical structure. Using the images of seven patients previously irradiated for cancer of brain or prostate cancer and one idealized scenario, competing three-dimensional conformal and IMRT plans were generated using different beam configurations. Within a given plan and for competing plans with a constant mean target dose, the normalized integral doses within concentric ''shells'' of surrounding normal tissue were quantitatively compared. Within each patient, the normalized integral dose to shells of normal tissue surrounding the target was relatively constant (1). Similarly, for each clinical scenario, the normalized integral dose for a given shell was also relatively constant regardless of the number and orientation of beams (2) or degree of sparing of a critical structure (3). 3D and IMRT planning tools can redistribute, rather than eliminate dose to the surrounding normal tissues (intuitively known by planners). More specifically, dose cannot be moved between shells surrounding the target but only within a shell. This implies that there are limitations in the extent to which a critical structure can be spared based on the location and geometry of the critical structure relative to the target.

  16. Investigation of the dose rate dependency of the PAGAT gel dosimeter at low dose rates

    International Nuclear Information System (INIS)

    Zehtabian, M.; Faghihi, R.; Zahmatkesh, M.H.; Meigooni, A.S.; Mosleh-Shirazi, M.A.; Mehdizadeh, S.; Sina, S.; Bagheri, S.

    2012-01-01

    Medical physicists need dosimeters such as gel dosimeters capable of determining three-dimensional dose distributions with high spatial resolution. To date, in combination with magnetic resonance imaging (MRI), polyacrylamide gel (PAG) polymers are the most promising gel dosimetry systems. The purpose of this work was to investigate the dose rate dependency of the PAGAT gel dosimeter at low dose rates. The gel dosimeter was used for measurement of the dose distribution around a Cs-137 source from a brachytherapy LDR source to have a range of dose rates from 0.97 Gy h −1 to 0.06 Gy h −1 . After irradiation of the PAGAT gel, it was observed that the dose measured by gel dosimetry was almost the same at different distances (different dose rates) from the source, although the points nearer the source had been expected to receive greater doses. Therefore, it was suspected that the PAGAT gel is dose rate dependent at low dose rates. To test this further, three other sets of measurements were performed by placing vials containing gel at different distances from a Cs-137 source. In the first two measurements, several plastic vials were exposed to equal doses at different dose rates. An ionization chamber was used to measure the dose rate at each distance. In addition, three TLD chips were simultaneously irradiated in order to verify the dose to each vial. In the third measurement, to test the oxygen diffusion through plastic vials, the experiment was repeated again using plastic vials in a nitrogen box and glass vials. The study indicates that oxygen diffusion through plastic vials for dose rates lower than 2 Gy h −1 would affect the gel dosimeter response and it is suggested that the plastic vials or (phantoms) in an oxygen free environment or glass vials should be used for the dosimetry of low dose rate sources using PAGAT gel to avoid oxygen diffusion through the vials.

  17. Establishment Of Dose Correlation During Dose Mapping On Medical Devices

    International Nuclear Information System (INIS)

    Ruzalina Baharin; Hasan Sham; Ahsanulkhaliqin Abdul Wahab

    2014-01-01

    This paper explains the work done during product dose mapping in order to get the correlation between doses at MINTec-Sinagama plant. Product used was medical devices in aluminium tubes packaged in cardboard kegs packaging with average weight of 12 kg per carton. 12 cartons were loaded in every one tote to give 0.2 g/ cm 3 of density. Ceric cerous dosimeters were placed at specific locations as indicated in SP14: Product Dose Mapping, QMS of MINTec-Sinagama around three planes. Three processes were made at different days as a three replicates to show the reproducibility of measurements. (author)

  18. Effects of low doses; Effet des faibles doses

    Energy Technology Data Exchange (ETDEWEB)

    Le Guen, B. [Electricite de France (EDF-LAM-SCAST), 93 - Saint-Denis (France)

    2001-07-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  19. Recommendations on dose buildup factors used in models for calculating gamma doses for a plume

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.; Thykier-Nielsen, S.

    1980-09-01

    Calculations of external γ-doses from radioactivity released to the atmosphere have been made using different dose buildup factor formulas. Some of the dose buildup factor formulas are used by the Nordic countries in their respective γ-dose models. A comparison of calculated γ-doses using these dose buildup factors shows that the γ-doses can be significantly dependent on the buildup factor formula used in the calculation. Increasing differences occur for increasing plume height, crosswind distance, and atmospheric stability and also for decreasing downwind distance. It is concluded that the most accurate γ-dose can be calculated by use of Capo's polynomial buildup factor formula. Capo-coefficients have been calculated and shown in this report for γ-energies below the original lower limit given by Capo. (author)

  20. A single-aliquot OSL protocol using bracketing regenerative doses to accurately determine equivalent doses in quartz

    CERN Document Server

    Folz, E

    1999-01-01

    In most cases, sediments show inherent heterogeneity in their luminescence behaviours and bleaching histories, and identical aliquots are not available: single-aliquot determination of the equivalent dose (ED) is then the approach of choice and the advantages of using regenerative protocols are outlined. Experiments on five laboratory bleached and dosed quartz samples, following the protocol described by Murray and Roberts (1998. Measurement of the equivalent dose in quartz using a regenerative-dose single aliquot protocol. Radiation Measurements 27, 171-184), showed the hazards of using a single regeneration dose: a 10% variation in the regenerative dose yielded some equivalent dose estimates that differed from the expected value by more than 5%. A protocol is proposed that allows the use of different regenerative doses to bracket the estimated equivalent dose. The measured ED is found to be in excellent agreement with the known value when the main regeneration dose is within 10% of the true equivalent dose.

  1. A single-aliquot OSL protocol using bracketing regenerative doses to accurately determine equivalent doses in quartz

    International Nuclear Information System (INIS)

    Folz, Elise; Mercier, Norbert

    1999-01-01

    In most cases, sediments show inherent heterogeneity in their luminescence behaviours and bleaching histories, and identical aliquots are not available: single-aliquot determination of the equivalent dose (ED) is then the approach of choice and the advantages of using regenerative protocols are outlined. Experiments on five laboratory bleached and dosed quartz samples, following the protocol described by Murray and Roberts (1998. Measurement of the equivalent dose in quartz using a regenerative-dose single aliquot protocol. Radiation Measurements 27, 171-184), showed the hazards of using a single regeneration dose: a 10% variation in the regenerative dose yielded some equivalent dose estimates that differed from the expected value by more than 5%. A protocol is proposed that allows the use of different regenerative doses to bracket the estimated equivalent dose. The measured ED is found to be in excellent agreement with the known value when the main regeneration dose is within 10% of the true equivalent dose

  2. Dose indices: everybody wants a number

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2014-01-01

    This paper discusses the merits and weaknesses of the standard terms that have been developed to quantify CT dose: CT dose indices (CTDI), dose length product (DLP) and effective dose. The difference between the measured CTDI vol and the CTDI vol displayed on the CT scanner illustrates a clinical dilemma. Displayed CTDI vol represents the radiation dose delivered to a plastic phantom, which is significantly different from the dose delivered to the patient, depending on the size of the patient. Although effective dose is simple to calculate for an individual patient, it was never intended for this purpose. The need for a simple, appropriate method to estimate pediatric patient doses led to the development of the size-specific dose estimate (SSDE), the newest CT dose index. Here I compare SSDE and its merits to the use of effective dose to estimate patient dose. The discussion concludes with a few sample calculations and basic clinical applications of SSDE to better quantify pediatric patient dose from CT scans. (orig.)

  3. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  4. Dose measurements in mammography

    International Nuclear Information System (INIS)

    Kainberger, F.; Kallinger, W.

    1977-01-01

    Dose measurements at the mamma during mammography were carried out in the form of direct measurement with thermoluminescent dosimetry. Measurement was done for the in- and outcoming doses at the mamma, the dose exposure of the sternal region and the scattered rays above the symphysis, the latter as parameter for the genetic radiation exposure. As expected, the dose of the smooth radiation used for mammography showed a strong decrease at the outcome point in comparison with the income point. Surprisingly high was the scattered radiation in the sternal region. A corresponding protection by lead plates could be taken into consideration. Extremely low is the scattered radiation above the symphysis. Even measurements with the very sensitive calcium fluoride dosimeters did not reveal any practically important dose in the symphysis region. Most measurement values remained below the determinable dose of 0.3mR. Some maximal values varied in the range of 3-1 mR. (orig.) [de

  5. A PC program for estimating organ dose and effective dose values in computed tomography

    International Nuclear Information System (INIS)

    Kalender, W.A.; Schmidt, B.; Schmidt, M.; Zankl, M.

    1999-01-01

    Dose values in CT are specified by the manufacturers for all CT systems and operating conditions in phantoms. It is not trivial, however, to derive dose values in patients from this information. Therefore, we have developed a PC-based program which calculates organ dose and effective dose values for arbitrary scan parameters and anatomical ranges. Values for primary radiation are derived from measurements or manufacturer specifications; values for scattered radiation are derived from Monte Carlo calculations tabulated for standard anthropomorphic phantoms. Based on these values, organ doses can be computed by the program for arbitrary scan protocols in conventional and in spiral CT. Effective dose values are also provided, both with ICRP 26 and ICRP 60 tissue-weighting coefficients. Results for several standard CT protocols are presented in tabular form in this paper. In addition, potential for dose reduction is demonstrated, for example, in spiral CT and in quantitative CT. Providing realistic patient dose estimates for arbitrary CT protocols is relevant both for the physician and the patient, and it is particularly useful for educational and training purposes. The program, called WinDose, is now in use at the Erlangen University hospitals (Germany) as an information tool for radiologists and patients. Further extensions are planned. (orig.)

  6. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  7. New dose limits and distribution of annual doses for controlled groups

    International Nuclear Information System (INIS)

    Vukcevic, M.; Stankovic, S.; Kovacevic, M.

    1993-01-01

    The new calculations of neutron doses received by the population of Hiroshima and Nagasaki, as well as the epidemiological data on the incidence of fatal cancers in the survivors, had led to the conclusion that the risk estimates should be raised by the factor 2 or 3. In this work, the distribution of monthly doses for occupationals was analysed in order to determine the percent of workers who might be considered as overexposed, on the basis of the new dose limits. (author)

  8. Detection of lung nodules with low-dose spiral CT: comparison with conventional dose CT

    International Nuclear Information System (INIS)

    Zhu Tianzhao; Tang Guangjian; Jiang Xuexiang

    2004-01-01

    Objective: To investigate the effect of reducing scan dose on the lung nodules detection rate by scanning a lung nodule model at low dose and conventional dose. Methods: The lung and the thoracic cage were simulated by using a cyst filled with water surrounded by a roll bandage. Flour, butter, and paraffin wax were mixed together by a certain ratio to simulate lung nodules of 10 mm and 5 mm in diameter with the CT values ranging from -10 to 50 HU. Conventional-dose scan (240 mA, 140 kV) and low-dose scan of three different levels (43 mA, 140 kV; 50 mA, 120 kV; 75 mA, 80 kV) together with three different pitches (1.0, 1.5, and 2.0) were performed. The images of the simulated nodules were combined with the CT images of a normal adult's upper, middle, and inferior lung. Three radiologists read the images and the number of the nodules they detected including both the real ones and the false-positive ones was calculated to investigate weather there was any difference among different doses, pitch groups, and different locations. Results: The detection rate of the 10 mm and 5 mm nodules was 100% and 89.6% respectively by the low-dose scan. There was no difference between low-dose and conventional-dose CT (χ 2 =0.6907, P>0.70). The detection rate of 5 mm nodules declined when large pitch was used. Conclusion: The detection rates of 10 mm and 5 mm nodules had no difference between low-dose CT and conventional-dose CT. As the pitch augmented, the detection rate for the nodules declined

  9. Physical requirements for measurement of radiation dose and their relationship to personnel dose meter design and use

    International Nuclear Information System (INIS)

    Chabot, G.E. Jr.; Jimenez, M.A.; Skrable, K.W.

    1978-01-01

    This paper stems from the concerns of the authors with both the design of current personnel dose meters and the interpretation of dose information from them in light of the actual physical requirements to measure dose. These concerns have been reinforced and extended following a comparative study of the responses of particular TLD and film systems and as the result of a recent national survey on personnel dosimetry conducted by the authors. Among the major points discussed are the systems available for penetrating and shallow dose assessment, dose meter calibration, the measurement and interpretation of skin dose, and the deficiencies of neutron albedo dose meters for routine personnel use. Calibration considerations address the questions of whether or not a phantom should be used and the difference in interpretation of responses with and without a phantom; the relationship between calculated and measured doses; and electronic equilibrium considerations in the measurement of photon doses. Matters of importance in relation to skin dose measurement include techniques in use to interpret skin dose from dose meter response; the appropriateness of evaluation of the surface dose to the live skin layer versus the average dose to the live skin layer and the limitations and requirements on dose meter design with respect to the dose being evaluated; and the significance of dose meter response in relationship to currently used beta calibration standards. Regarding the use of TLD albedo type neutron dose meters currently available, considerations are extended to the strong energy spectral dependence of the dose meter response and the possibility of making significant over or underestimations of neutron dose equivalent, depending on the calibration techniques used and the spectral quality encountered. (author)

  10. Dose and dose-rate effects of ionizing radiation: a discussion in the light of radiological protection

    Energy Technology Data Exchange (ETDEWEB)

    Ruehm, Werner [Helmholtz Zentrum Muenchen, German Research Center for Environmental Health, Institute of Radiation Protection, Neuherberg (Germany); Woloschak, Gayle E. [Northwestern University, Department of Radiation Oncology, Feinberg School of Medicine, Chicago, IL (United States); Shore, Roy E. [Radiation Effects Research Foundation (RERF), Hiroshima City (Japan); Azizova, Tamara V. [Southern Urals Biophysics Institute (SUBI), Ozyorsk, Chelyabinsk Region (Russian Federation); Grosche, Bernd [Federal Office for Radiation Protection, Oberschleissheim (Germany); Niwa, Ohtsura [Fukushima Medical University, Fukushima (Japan); Akiba, Suminori [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Epidemiology and Preventive Medicine, Kagoshima City (Japan); Ono, Tetsuya [Institute for Environmental Sciences, Rokkasho, Aomori-ken (Japan); Suzuki, Keiji [Nagasaki University, Department of Radiation Medical Sciences, Atomic Bomb Disease Institute, Nagasaki (Japan); Iwasaki, Toshiyasu [Central Research Institute of Electric Power Industry (CRIEPI), Radiation Safety Research Center, Nuclear Technology Research Laboratory, Tokyo (Japan); Ban, Nobuhiko [Tokyo Healthcare University, Faculty of Nursing, Tokyo (Japan); Kai, Michiaki [Oita University of Nursing and Health Sciences, Department of Environmental Health Science, Oita (Japan); Clement, Christopher H.; Hamada, Nobuyuki [International Commission on Radiological Protection (ICRP), PO Box 1046, Ottawa, ON (Canada); Bouffler, Simon [Public Health England (PHE), Centre for Radiation, Chemical and Environmental Hazards, Chilton, Didcot (United Kingdom); Toma, Hideki [JAPAN NUS Co., Ltd. (JANUS), Tokyo (Japan)

    2015-11-15

    The biological effects on humans of low-dose and low-dose-rate exposures to ionizing radiation have always been of major interest. The most recent concept as suggested by the International Commission on Radiological Protection (ICRP) is to extrapolate existing epidemiological data at high doses and dose rates down to low doses and low dose rates relevant to radiological protection, using the so-called dose and dose-rate effectiveness factor (DDREF). The present paper summarizes what was presented and discussed by experts from ICRP and Japan at a dedicated workshop on this topic held in May 2015 in Kyoto, Japan. This paper describes the historical development of the DDREF concept in light of emerging scientific evidence on dose and dose-rate effects, summarizes the conclusions recently drawn by a number of international organizations (e.g., BEIR VII, ICRP, SSK, UNSCEAR, and WHO), mentions current scientific efforts to obtain more data on low-dose and low-dose-rate effects at molecular, cellular, animal and human levels, and discusses future options that could be useful to improve and optimize the DDREF concept for the purpose of radiological protection. (orig.)

  11. Internal dose conversion factors for calculation of dose to the public

    International Nuclear Information System (INIS)

    1988-07-01

    This publication contains 50-year committed dose equivalent factors, in tabular form. The document is intended to be used as the primary reference by the US Department of Energy (DOE) and its contractors for calculating radiation dose equivalents for members of the public, resulting from ingestion or inhalation of radioactive materials. Its application is intended specifically for such materials released to the environment during routine DOE operations, except in those instances where compliance with 40 CFR 61 (National Emission Standards for Hazardous Air Pollutants) requires otherwise. However, the calculated values may be equally applicable to unusual releases or to occupational exposures. The use of these committed dose equivalent tables should ensure that doses to members of the public from internal exposures are calculated in a consistent manner at all DOE facilities

  12. Failure-probability driven dose painting

    International Nuclear Information System (INIS)

    Vogelius, Ivan R.; Håkansson, Katrin; Due, Anne K.; Aznar, Marianne C.; Kristensen, Claus A.; Rasmussen, Jacob; Specht, Lena; Berthelsen, Anne K.; Bentzen, Søren M.

    2013-01-01

    Purpose: To demonstrate a data-driven dose-painting strategy based on the spatial distribution of recurrences in previously treated patients. The result is a quantitative way to define a dose prescription function, optimizing the predicted local control at constant treatment intensity. A dose planning study using the optimized dose prescription in 20 patients is performed.Methods: Patients treated at our center have five tumor subvolumes from the center of the tumor (PET positive volume) and out delineated. The spatial distribution of 48 failures in patients with complete clinical response after (chemo)radiation is used to derive a model for tumor control probability (TCP). The total TCP is fixed to the clinically observed 70% actuarial TCP at five years. Additionally, the authors match the distribution of failures between the five subvolumes to the observed distribution. The steepness of the dose–response is extracted from the literature and the authors assume 30% and 20% risk of subclinical involvement in the elective volumes. The result is a five-compartment dose response model matching the observed distribution of failures. The model is used to optimize the distribution of dose in individual patients, while keeping the treatment intensity constant and the maximum prescribed dose below 85 Gy.Results: The vast majority of failures occur centrally despite the small volumes of the central regions. Thus, optimizing the dose prescription yields higher doses to the central target volumes and lower doses to the elective volumes. The dose planning study shows that the modified prescription is clinically feasible. The optimized TCP is 89% (range: 82%–91%) as compared to the observed TCP of 70%.Conclusions: The observed distribution of locoregional failures was used to derive an objective, data-driven dose prescription function. The optimized dose is predicted to result in a substantial increase in local control without increasing the predicted risk of toxicity

  13. Committed equivalent organ doses and committed effective doses from intakes of radionuclides

    CERN Document Server

    Phipps, A W; Kendall, G M; Silk, T J; Stather, J W

    1991-01-01

    This report contains details of committed equivalent doses to individual organs for intakes by ingestion and inhalation of 1 mu m AMAD particles of 359 nuclides by infants aged 3 months, by children aged 1, 5, 10 and 15 years, and by adults. It complements NRPB-R245 which describes the changes which have taken place since the last NRPB compendium of dose per unit intake factors (dose coefficients) and gives summary tables. Information on the way committed doses increase with the integration period is given in NRPB-M289. The information given in these memoranda is also available as a microcomputer package - NRPB-SR245.

  14. Mathematical model for evaluation of dose-rate effect on biological responses to low dose γ-radiation

    International Nuclear Information System (INIS)

    Ogata, H.; Kawakami, Y.; Magae, J.

    2003-01-01

    Full text: To evaluate quantitative dose-response relationship on the biological response to radiation, it is necessary to consider a model including cumulative dose, dose-rate and irradiation time. In this study, we measured micronucleus formation and [ 3 H] thymidine uptake in human cells as indices of biological response to gamma radiation, and analyzed mathematically and statistically the data for quantitative evaluation of radiation risk at low dose/low dose-rate. Effective dose (ED x ) was mathematically estimated by fitting a general function of logistic model to the dose-response relationship. Assuming that biological response depends on not only cumulative dose but also dose-rate and irradiation time, a multiple logistic function was applied to express the relationship of the three variables. Moreover, to estimate the effect of radiation at very low dose, we proposed a modified exponential model. From the results of fitting curves to the inhibition of [ 3 H] thymidine uptake and micronucleus formation, it was obvious that ED 50 in proportion of inhibition of [ 3 H] thymidine uptake increased with longer irradiation time. As for the micronuclei, ED 30 also increased with longer irradiation times. These results suggest that the biological response depends on not only total dose but also irradiation time. The estimated response surface using the three variables showed that the biological response declined sharply when the dose-rate was less than 0.01 Gy/h. These results suggest that the response does not depend on total cumulative dose at very low dose-rates. Further, to investigate the effect of dose-rate within a wider range, we analyzed the relationship between ED x and dose-rate. Fitted curves indicated that ED x increased sharply when dose-rate was less than 10 -2 Gy/h. The increase of ED x signifies the decline of the response or the risk and suggests that the risk approaches to 0 at infinitely low dose-rate

  15. Dose-mapping distribution around MNSR

    CERN Document Server

    Jamal, M H

    2002-01-01

    The aim of this study is to establish the dose-rate map through the determination of radiological dose-rate levels in reactor hall, adjacent rooms, and outside the MNSR facility. Controlling dose rate to reactor operating personnel , dose map was established. The map covers time and distances in the reactor hall, during reactor operation at nominal power. Different measurement of dose rates in other areas of the reactor buildings was established. The maximum dose rate, during normal operation of the MNSR was 40 and 21 Sv/hr on the top of the reactor and near the pool fence, respectively. Whereas, gamma and neutron doses have not exceeded natural background in all rooms adjacent to the reactor hall or nearly buildings. The relation between the dose rate for gamma rays and neutron flux at the top of cover of reactor pool was studied as well. It was found that this relation is linear.

  16. Dose-mapping distribution around MNSR

    International Nuclear Information System (INIS)

    Jamal, M. H.; Khamis, I.

    2002-12-01

    The aim of this study is to establish the dose-rate map through the determination of radiological dose-rate levels in reactor hall, adjacent rooms, and outside the MNSR facility. Controlling dose rate to reactor operating personnel , dose map was established. The map covers time and distances in the reactor hall, during reactor operation at nominal power. Different measurement of dose rates in other areas of the reactor buildings was established. The maximum dose rate, during normal operation of the MNSR was 40 and 21 Sv/hr on the top of the reactor and near the pool fence, respectively. Whereas, gamma and neutron doses have not exceeded natural background in all rooms adjacent to the reactor hall or nearly buildings. The relation between the dose rate for gamma rays and neutron flux at the top of cover of reactor pool was studied as well. It was found that this relation is linear. (author)

  17. Update on pediatric resuscitation drugs: high dose, low dose, or no dose at all.

    Science.gov (United States)

    Sorrentino, Annalise

    2005-04-01

    Pediatric resuscitation has been a topic of discussion for years. It is difficult to keep abreast of changing recommendations, especially for busy pediatricians who do not regularly use these skills. This review will focus on the most recent guidelines for resuscitation drugs. Three specific questions will be discussed: standard dose versus high-dose epinephrine, amiodarone use, and the future of vasopressin in pediatric resuscitation. The issue of using high-dose epinephrine for cardiopulmonary resuscitation refractory to standard dose epinephrine has been a topic of debate for many years. Recently, a prospective, double-blinded study was performed to help settle the debate. These results will be reviewed and compared with previous studies. Amiodarone is a medication that was added to the pediatric resuscitation algorithms with the most recent recommendations from the American Heart Association in 2000. Its use and safety will also be discussed. Another topic that is resurfacing in resuscitation is the use of vasopressin. Its mechanism and comparisons to other agents will be highlighted, although its use in the pediatric patient has not been thoroughly studied. Pediatric resuscitation is a constantly evolving subject that is on the mind of anyone taking care of sick children. Clinicians are continually searching for the most effective methods to resuscitate children in terms of short- and long-term outcomes. It is important to be familiar with not only the agents being used but also the optimal way to use them.

  18. RSAC, Gamma Doses, Inhalation and Ingestion Doses, Fission Products Inventory after Fission Products Release

    International Nuclear Information System (INIS)

    Richardson, L.C.

    1967-01-01

    1 - Description of problem or function: RSAC generates a fission product inventory from a given set of reactor operating conditions and then computes the external gamma dose, the deposition gamma dose, and the inhalation-ingestion dose to critical body organs as a result of exposure to these fission products. Program output includes reactor operating history, fission product inventory, dosages, and ingestion parameters. 2 - Method of solution: The fission product inventory generated by the reactor operating conditions and the inventory remaining at various times after release are computed using the equations of W. Rubinson in Journal of Chemical Physics, Vol. 17, pages 542-547, June 1949. The external gamma dose and the deposition gamma dose are calculated by determining disintegration rates as a function of space and time, then integrating using Hermite's numerical techniques for the spatial dependence. The inhalation-ingestion dose is determined by the type and quantity of activity inhaled and the biological rate of decay following inhalation. These quantities are integrated with respect to time to obtain the dosage. The ingestion dose is related to the inhalation dose by an input constant

  19. Radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Cohnen, M.; Kemper, J.; Moedder, U.; Moebes, O.; Pawelzik, J.

    2002-01-01

    The aim of this study was to compare radiation exposure in panoramic radiography (PR), dental CT, and digital volume tomography (DVT). An anthropomorphic Alderson-Rando phantom and two anatomical head phantoms with thermoluminescent dosimeters fixed at appropriate locations were exposed as in a dental examination. In PR and DVT, standard parameters were used while variables in CT included mA, pitch, and rotation time. Image noise was assessed in dental CT and DVT. Radiation doses to the skin and internal organs within the primary beam and resulting from scatter radiation were measured and expressed as maximum doses in mGy. For PR, DVT, and CT, these maximum doses were 0.65, 4.2, and 23 mGy. In dose-reduced CT protocols, radiation doses ranged from 10.9 to 6.1 mGy. Effective doses calculated on this basis showed values below 0.1 mSv for PR, DVT, and dose-reduced CT. Image noise was similar in DVT and low-dose CT. As radiation exposure and image noise of DVT is similar to low-dose CT, this imaging technique cannot be recommended as a general alternative to replace PR in dental radiology. (orig.)

  20. Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry

    International Nuclear Information System (INIS)

    Calcina, Carmen S Guzman; Almeida, Adelaide de; Rocha, Jose R Oliveira; Abrego, Felipe Chen; Baffa, Oswaldo

    2005-01-01

    Source positioning close to the tumour in high dose rate (HDR) brachytherapy is not instantaneous. An increment of dose will be delivered during the movement of the source in the trajectory to its static position. This increment is the transit dose, often not taken into account in brachytherapeutic treatment planning. The transit dose depends on the prescribed dose, number of treatment fractions, velocity and activity of the source. Combining all these factors, the transit dose can be 5% higher than the prescribed absorbed dose value (Sang-Hyun and Muller-Runkel, 1994 Phys. Med. Biol. 39 1181-8, Nath et al 1995 Med. Phys. 22 209-34). However, it cannot exceed this percentage (Nath et al 1995). In this work, we use the alanine-EPR (electron paramagnetic resonance) dosimetric system using analysis of the first derivative of the signal. The transit dose was evaluated for an HDR system and is consistent with that already presented for TLD dosimeters (Bastin et al 1993 Int. J. Radiat. Oncol. Biol. Phys. 26 695-702). Also using the same dosimetric system, the radial dose function, used to evaluate the geometric dose degradation around the source, was determined and its behaviour agrees better with those obtained by Monte Carlo simulations (Nath et al 1995, Williamson and Nath 1991 Med. Phys. 18 434-48, Ballester et al 1997 Med. Phys. 24 1221-8, Ballester et al 2001 Phys. Med. Biol. 46 N79-90) than with TLD measurements (Nath et al 1990 Med. Phys. 17 1032-40)

  1. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    Science.gov (United States)

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.

  2. Radiation dose to technologists per nuclear medicine examination and estimation of annual dose.

    Science.gov (United States)

    Bayram, Tuncay; Yilmaz, A Hakan; Demir, Mustafa; Sonmez, Bircan

    2011-03-01

    Conventional diagnostic nuclear medicine applications have been continuously increasing in most nuclear medicine departments in Turkey, but to our knowledge no one has studied the doses to technologists who perform nuclear medicine procedures. Most nuclear medicine laboratories do not have separate control rooms for technologists, who are quite close to the patient during data acquisition. Technologists must therefore stay behind lead shields while performing their task if they are to reduce the radiation dose received. The aim of this study was to determine external radiation doses to technologists during nuclear medicine procedures with and without a lead shield. Another aim was to investigate the occupational annual external radiation doses to Turkish technologists. This study used a Geiger-Müller detector to measure dose rates to technologists at various distances from patients (0.25, 0.50, 1, and 2 m and behind a lead shield) and determined the average time spent by technologists at these distances. Deep-dose equivalents to technologists were obtained. The following conventional nuclear medicine procedures were considered: thyroid scintigraphy performed using (99m)Tc pertechnetate, whole-body bone scanning performed using (99m)Tc-methylene diphosphonate, myocardial perfusion scanning performed using (99m)Tc-methoxyisobutyl isonitrile, and (201)Tl (thallous chloride) and renal scanning performed using (99m)Tc-dimercaptosuccinic acid. The measured deep-dose equivalent to technologists per procedure was within the range of 0.13 ± 0.05 to 0.43 ± 0.17 μSv using a lead shield and 0.21 ± 0.07 to 1.01 ± 0.46 μSv without a lead shield. Also, the annual individual dose to a technologist performing only a particular scintigraphic procedure throughout a year was estimated. For a total of 95 clinical cases (71 patients), effective external radiation doses to technologists were found to be within the permissible levels. This study showed that a 2-mm lead shield

  3. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  4. Dose-to-medium vs. dose-to-water: Dosimetric evaluation of dose reporting modes in Acuros XB for prostate, lung and breast cancer

    Directory of Open Access Journals (Sweden)

    Suresh Rana

    2014-12-01

    Full Text Available Purpose: Acuros XB (AXB dose calculation algorithm is available for external beam photon dose calculations in Eclipse treatment planning system (TPS. The AXB can report the absorbed dose in two modes: dose-to-water (Dw and dose-to-medium (Dm. The main purpose of this study was to compare the dosimetric results of the AXB_Dm with that of AXB_Dw on real patient treatment plans. Methods: Four groups of patients (prostate cancer, stereotactic body radiation therapy (SBRT lung cancer, left breast cancer, and right breast cancer were selected for this study, and each group consisted of 5 cases. The treatment plans of all cases were generated in the Eclipse TPS. For each case, treatment plans were computed using AXB_Dw and AXB_Dm for identical beam arrangements. Dosimetric evaluation was done by comparing various dosimetric parameters in the AXB_Dw plans with that of AXB_Dm plans for the corresponding patient case. Results: For the prostate cancer, the mean planning target volume (PTV dose in the AXB_Dw plans was higher by up to 1.0%, but the mean PTV dose was within ±0.3% for the SBRT lung cancer. The analysis of organs at risk (OAR results in the prostate cancer showed that AXB_Dw plans consistently produced higher values for the bladder and femoral heads but not for the rectum. In the case of SBRT lung cancer, a clear trend was seen for the heart mean dose and spinal cord maximum dose, with AXB_Dw plans producing higher values than the AXB_Dm plans. However, the difference in the lung doses between the AXB_Dm and AXB_Dw plans did not always produce a clear trend, with difference ranged from -1.4% to 2.9%. For both the left and right breast cancer, the AXB_Dm plans produced higher maximum dose to the PTV for all cases. The evaluation of the maximum dose to the skin showed higher values in the AXB_Dm plans for all 5 left breast cancer cases, whereas only 2 cases had higher maximum dose to the skin in the AXB_Dm plans for the right breast cancer

  5. KERMA-based radiation dose management system for real-time patient dose measurement

    Science.gov (United States)

    Kim, Kyo-Tae; Heo, Ye-Ji; Oh, Kyung-Min; Nam, Sang-Hee; Kang, Sang-Sik; Park, Ji-Koon; Song, Yong-Keun; Park, Sung-Kwang

    2016-07-01

    Because systems that reduce radiation exposure during diagnostic procedures must be developed, significant time and financial resources have been invested in constructing radiation dose management systems. In the present study, the characteristics of an existing ionization-based system were compared to those of a system based on the kinetic energy released per unit mass (KERMA). Furthermore, the feasibility of using the KERMA-based system for patient radiation dose management was verified. The ionization-based system corrected the effects resulting from radiation parameter perturbations in general radiography whereas the KERMA-based system did not. Because of this difference, the KERMA-based radiation dose management system might overestimate the patient's radiation dose due to changes in the radiation conditions. Therefore, if a correction factor describing the correlation between the systems is applied to resolve this issue, then a radiation dose management system can be developed that will enable real-time measurement of the patient's radiation exposure and acquisition of diagnostic images.

  6. Dose intercomparison studies for standardization of high-dose dosimetry in Viet Nam

    International Nuclear Information System (INIS)

    Mai Hoang Hoa; Duong Nguyen Dinh; Kojima, T.

    1999-01-01

    The Irradiation Center of the Vietnam Atomic Energy Commission (IC-VAEC) is planning to establish a traceability system for high-dose dosimetry and to provide high-dose standards as a secondary standard dosimetry laboratory (SSDL) level in Vietnam. For countries which do not have a standard dosimetry laboratory, the participation in the International Dose Assurance Service (IDAS) operated by the International Atomic Energy Agency (IAEA) is the most common means to verify own dosimetry performance with a certain uncertainty. This is, however, only one-direction dose intercomparison with evaluation by IAEA including unknown parameter at participant laboratories. The SSDL level laboratory should have traceability as well as compatibility, ability to evaluate uncertainties of its own dosimetry performance by itself In the present paper, we reviewed our dosimetry performance through two-way dose intercomparison studies and self-evaluation of uncertainty in our dosimetry procedure. The performance of silver dichromate dosimeter as reference transfer dosimeter in IC-VAEC was studied through two-way blind dose intercomparison experiments between the IC-VAEC and JAERI. As another channel of dose intercomparison with IAEA, alanine dosimeters issued by IDAS were simultaneously irradiated with the IC-VAEC dichromate dosimeters at IC-VAEC and analyzed by IAEA. Dose intercomparison between IC-VAEC and JAERI results into a good agreement (better than ±2.5%), and IDAS results also show similar agreement within ±3.0%. The uncertainty was self-estimated on the basis of the JAERI alanine dosimetry, and a preliminary value of about 1.86% at a 68% confidence level is established. The results from these intercomparisons and our estimation of the uncertainty are consistent. We hope that our experience is valuable to other countries which do not have dosimetry standard laboratories and/or are planning to establish them. (author)

  7. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  8. Influence of Genotype on Warfarin Maintenance Dose Predictions Produced Using a Bayesian Dose Individualization Tool.

    Science.gov (United States)

    Saffian, Shamin M; Duffull, Stephen B; Roberts, Rebecca L; Tait, Robert C; Black, Leanne; Lund, Kirstin A; Thomson, Alison H; Wright, Daniel F B

    2016-12-01

    A previously established Bayesian dosing tool for warfarin was found to produce biased maintenance dose predictions. In this study, we aimed (1) to determine whether the biased warfarin dose predictions previously observed could be replicated in a new cohort of patients from 2 different clinical settings, (2) to explore the influence of CYP2C9 and VKORC1 genotype on predictive performance of the Bayesian dosing tool, and (3) to determine whether the previous population used to develop the kinetic-pharmacodynamic model underpinning the Bayesian dosing tool was sufficiently different from the test (posterior) population to account for the biased dose predictions. The warfarin maintenance doses for 140 patients were predicted using the dosing tool and compared with the observed maintenance dose. The impact of genotype was assessed by predicting maintenance doses with prior parameter values known to be altered by genetic variability (eg, EC50 for VKORC1 genotype). The prior population was evaluated by fitting the published kinetic-pharmacodynamic model, which underpins the Bayesian tool, to the observed data using NONMEM and comparing the model parameter estimates with published values. The Bayesian tool produced positively biased dose predictions in the new cohort of patients (mean prediction error [95% confidence interval]; 0.32 mg/d [0.14-0.5]). The bias was only observed in patients requiring ≥7 mg/d. The direction and magnitude of the observed bias was not influenced by genotype. The prior model provided a good fit to our data, which suggests that the bias was not caused by different prior and posterior populations. Maintenance doses for patients requiring ≥7 mg/d were overpredicted. The bias was not due to the influence of genotype nor was it related to differences between the prior and posterior populations. There is a need for a more mechanistic model that captures warfarin dose-response relationship at higher warfarin doses.

  9. Conditioned instrumental behaviour in the rat: Effects of prenatal irradiation with various low dose-rate doses

    International Nuclear Information System (INIS)

    Klug, H.

    1986-01-01

    4 groups of rats of the Wistar-strain were subjected to γ-irradiation on the 16th day of gestation. 5 rats received 0,6 Gy low dose rate irradiation, 5 animals received 0,9 Gy low dose and 6 high dose irradiation, 3 females were shamirradiated. The male offspring of these 3 irradiation groups and 1 control group were tested for locomotor coordination on parallel bars and in a water maze. The female offspring were used in an operant conditioning test. The locomotor test showed slight impairment of locomotor coordination in those animals irradiated with 0,9 Gy high dose rate. Swimming ability was significantly impaired by irradiation with 0,9 Gy high dose rate. Performance in the operant conditioning task was improved by irradiation with 0,9 Gy both low and high dose rate. The 0,9 Gy high dose rate group learned faster than all the other groups. For the dose of 0,9 Gy a significant dose rate effect could be observed. For the dose of 0,6 Gy a similar tendency was observed, differences between 0,6 Gy high and low dose rate and controls not being significant. (orig./MG) [de

  10. Doses from radiation exposure

    International Nuclear Information System (INIS)

    Menzel, H-G.; Harrison, J.D.

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection’s (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP’s 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effective dose. In preparation for the calculation of new dose coefficients, Committee 2 and its task groups have provided updated nuclear decay data (ICRP Publication 107) and adult reference computational phantoms (ICRP Publication 110). New dose coefficients for external exposures of workers are complete (ICRP Publication 116), and work is in progress on a series of reports on internal dose coefficients to workers from inhaled and ingested radionuclides. Reference phantoms for children will also be provided and used in the calculation of dose coefficients for public exposures. Committee 2 also has task groups on exposures to radiation in space and on the use of effective dose.

  11. Equivalent dose, effective dose and risk assessment from cephalometric radiography to critical organs

    International Nuclear Information System (INIS)

    Kang, Seong Sook; Cho, Bon Hae; Kim, Hyun Ja

    1995-01-01

    In head and neck region, the critical organ and tissue doses were determined, and the risks were estimated from lateral, posteroanterial and basilar cephalometric radiography. For each cephalometric radiography, 31 TLDs were placed in selected sites (18 internal and 13 external sites) in a tissue-equivalent phantom and exposed, then read-out in the TLD reader. The following results were obtained; 1. From lateral cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (3.6 μSv) and the next highest dose was that received by the bone marrow (3 μSv). 2. From posteroanterial cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (2 μSv) and the next highest dose was that received by the bone marrow (1.8 μSv). 3. From basilar cephalometric radiography, the highest effective dose recorded was that delivered to the thyroid gland (31.4 μSv) and the next highest dose was that received by the salivary gland (13.3 μSv). 4. The probabilities of stochastic effect from lateral, posteroanterial and basilar cephalometric radiography were 0.72 X 10 -6 , 0.49 X 10 -6 and 3.51 X 10 -6 , respectively.

  12. Dose Recalculation and the Dose-Guided Radiation Therapy (DGRT) Process Using Megavoltage Cone-Beam CT

    International Nuclear Information System (INIS)

    Cheung, Joey; Aubry, Jean-Francois; Yom, Sue S.; Gottschalk, Alexander R.; Celi, Juan Carlos; Pouliot, Jean

    2009-01-01

    Purpose: At University of California San Francisco, daily or weekly three-dimensional images of patients in treatment position are acquired for image-guided radiation therapy. These images can be used for calculating the actual dose delivered to the patient during treatment. In this article, we present the process of performing dose recalculation on megavoltage cone-beam computed tomography images and discuss possible strategies for dose-guided radiation therapy (DGRT). Materials and Methods: A dedicated workstation has been developed to incorporate the necessary elements of DGRT. Patient image correction (cupping, missing data artifacts), calibration, completion, recontouring, and dose recalculation are all implemented in the workstation. Tools for dose comparison are also included. Examples of image correction and dose analysis using 6 head-and-neck and 2 prostate patient datasets are presented to show possible tracking of interfraction dosimetric endpoint variation over the course of treatment. Results: Analysis of the head-and-neck datasets shows that interfraction treatment doses vary compared with the planning dose for the organs at risk, with the mean parotid dose and spinal cord D 1 increasing by as much as 52% and 10%, respectively. Variation of the coverage to the target volumes was small, with an average D 5 dose difference of 1%. The prostate patient datasets revealed accurate dose coverage to the targeted prostate and varying interfraction dose distributions to the organs at risk. Conclusions: An effective workflow for the clinical implementation of DGRT has been established. With these techniques in place, future clinical developments in adaptive radiation therapy through daily or weekly dosimetric measurements of treatment day images are possible.

  13. CT dose management

    International Nuclear Information System (INIS)

    Zasheva, Ts.; Georgiev, E.; Kirova, G.

    2013-01-01

    Full text: Introduction: In recent decades Computed Tomography established itself as one of the most common study with a very wide range of applications and techniques of scanning. Best diagnostic value of the method resist to the risks of ionizing radiation, as statistics show that CT is one of the main sources of continuously increasing dose to the population. What you will learn: The physical parameters of the X-ray tube and the principles of image reconstruction; The relationship between variables parameters and the received dose; The ratio between the force and voltage of the current to the image quality, Influence of the used contrast medium to the physical properties of the image, The ratio of patient BMI to image processing, Effective use of knowledge for the optimal CT protocol. Discussions: The goal to reduce the dose received by the patient during a CT scan while keeping the diagnostic quality of the image puts to the test as handset X-ray producers and technicians who need to master the technique of study protocol forming as well as to balance the harm - benefit ratio. Among the most popular techniques are these of dose modulation, low-dose computed tomography at the expense of a reduction of the current or voltage intensity, and control of the number of post-processing algorithms for the image reconstruction. Conclusion: The training of radiologists and X-ray technicians plays a major role in optimizing of technical parameters in view of the reduction of the dose for the patient, while maintaining the diagnostic quality of the image

  14. Dose-response relationship for breast cancer induction at radiotherapy dose

    Directory of Open Access Journals (Sweden)

    Gruber Günther

    2011-06-01

    Full Text Available Abstract Purpose Cancer induction after radiation therapy is known as a severe side effect. It is therefore of interest to predict the probability of second cancer appearance for the patient to be treated including breast cancer. Materials and methods In this work a dose-response relationship for breast cancer is derived based on (i the analysis of breast cancer induction after Hodgkin's disease, (ii a cancer risk model developed for high doses including fractionation based on the linear quadratic model, and (iii the reconstruction of treatment plans for Hodgkin's patients treated with radiotherapy, (iv the breast cancer induction of the A-bomb survivor data. Results The fitted model parameters for an α/β = 3 Gy were α = 0.067Gy-1 and R = 0.62. The risk for breast cancer is according to this model for small doses consistent with the finding of the A-bomb survivors, has a maximum at doses of around 20 Gy and drops off only slightly at larger doses. The predicted EAR for breast cancer after radiotherapy of Hodgkin's disease is 11.7/10000PY which can be compared to the findings of several epidemiological studies where EAR for breast cancer varies between 10.5 and 29.4/10000PY. The model was used to predict the impact of the reduction of radiation volume on breast cancer risk. It was estimated that mantle field irradiation is associated with a 3.2-fold increased risk compared with mediastinal irradiation alone, which is in agreement with a published value of 2.7. It was also shown that the modelled age dependency of breast cancer risk is in satisfying agreement with published data. Conclusions The dose-response relationship obtained in this report can be used for the prediction of radiation induced secondary breast cancer of radiotherapy patients.

  15. In defence of collective dose

    International Nuclear Information System (INIS)

    Fairlie, I.; Sumner, D.

    2000-01-01

    Recent proposals for a new scheme of radiation protection leave little room for collective dose estimations. This article discusses the history and present use of collective doses for occupational, ALARA, EIS and other purposes with reference to practical industry papers and government reports. The linear no-threshold (LNT) hypothesis suggests that collective doses which consist of very small doses added together should be used. Moral and ethical questions are discussed, particularly the emphasis on individual doses to the exclusion of societal risks, uncertainty over effects into the distant future and hesitation over calculating collective detriments. It is concluded that for moral, practical and legal reasons, collective dose is a valid parameter which should continue to be used. (author)

  16. Carcinogenesis in mice after low doses and dose rates

    International Nuclear Information System (INIS)

    Ullrich, R.L.

    1979-01-01

    The results from the experimental systems reported here indicate that the dose-response curves for tumor induction in various tissues cannot be described by a single model. Furthermore, although the understanding of the mechanisms involved in different systems is incomplete, it is clear that very different mechanisms for induction are involved. For some tumors the mechanism of carcinogenesis may be mainly a result of direct effects on the target cell, perhaps involving one or more mutations. While induction may occur, in many instances, through such direct effects, the eventual expression of the tumor can be influenced by a variety of host factors including endocrine status, competence of the immune system, and kinetics of target and interacting cell populations. In other tumors, indirect effects may play a major role in the initiation or expression of tumors. Some of the hormone-modulated tumors would fall into this class. Despite the complexities of the experimental systems and the lack of understanding of the types of mechanisms involved, in nearly every example the tumorigenic effectiveness per rad of low-LET radiation tends to decrease with decreasing dose rate. For some tumor types the differences may be small or may appear only with very low dose rates, while for others the dose-rate effects may be large

  17. Towards a new dose and dose-rate effectiveness factor (DDREF)? Some comments.

    Science.gov (United States)

    Chadwick, K H

    2017-06-26

    The aim of this article is to offer a broader, mechanism-based, analytical tool than that used by (Rühm et al 2016 Ann. ICRP 45 262-79) for the interpretation of cancer induction relationships. The article explains the limitations of this broader analytical tool and the implications of its use in view of the publications by Leuraud et al 2015 (Lancet Haematol. 2 e276-81) and Richardson et al 2015 (Br. Med. J. 351 h5359). The publication by Rühm et al 2016 (Ann. ICRP 45 262-79), which is clearly work in progress, reviews the current status of the dose and dose-rate effectiveness factor (DDREF) as recommended by the ICRP. It also considers the issues which might influence a reassessment of both the value of the DDREF as well as its application in radiological protection. In this article, the problem is approached from a different perspective and starts by commenting on the limited scientific data used by Rühm et al 2016 (Ann. ICRP 45 262-79) to develop their analysis which ultimately leads them to use a linear-quadratic dose effect relationship to fit solid cancer mortality data from the Japanese life span study of atomic bomb survivors. The approach taken here includes more data on the induction of DNA double strand breaks and, using experimental data taken from the literature, directly relates the breaks to cell killing, chromosomal aberrations and somatic mutations. The relationships are expanded to describe the induction of cancer as arising from radiation induced cytological damage coupled to cell killing since the cancer mutated cell has to survive to express its malignant nature. Equations are derived for the induction of cancer after both acute and chronic exposure to sparsely ionising radiation. The equations are fitted to the induction of cancer in mice to illustrate a dose effect relationship over the total dose range. The 'DDREF' derived from the two equations varies with dose and the DDREF concept is called into question. Although the equation for

  18. Choline PET based dose-painting in prostate cancer - Modelling of dose effects

    International Nuclear Information System (INIS)

    Niyazi, Maximilian; Bartenstein, Peter; Belka, Claus; Ganswindt, Ute

    2010-01-01

    Several randomized trials have documented the value of radiation dose escalation in patients with prostate cancer, especially in patients with intermediate risk profile. Up to now dose escalation is usually applied to the whole prostate. IMRT and related techniques currently allow for dose escalation in sub-volumes of the organ. However, the sensitivity of the imaging modality and the fact that small islands of cancer are often dispersed within the whole organ may limit these approaches with regard to a clear clinical benefit. In order to assess potential effects of a dose escalation in certain sub-volumes based on choline PET imaging a mathematical dose-response model was developed. Based on different assumptions for α/β, γ50, sensitivity and specificity of choline PET, the influence of the whole prostate and simultaneous integrated boost (SIB) dose on tumor control probability (TCP) was calculated. Based on the given heterogeneity of all potential variables certain representative permutations of the parameters were chosen and, subsequently, the influence on TCP was assessed. Using schedules with 74 Gy within the whole prostate and a SIB dose of 90 Gy the TCP increase ranged from 23.1% (high detection rate of choline PET, low whole prostate dose, high γ50/ASTRO definition for tumor control) to 1.4% TCP gain (low sensitivity of PET, high whole prostate dose, CN + 2 definition for tumor control) or even 0% in selected cases. The corresponding initial TCP values without integrated boost ranged from 67.3% to 100%. According to a large data set of intermediate-risk prostate cancer patients the resulting TCP gains ranged from 22.2% to 10.1% (ASTRO definition) or from 13.2% to 6.0% (CN + 2 definition). Although a simplified mathematical model was employed, the presented model allows for an estimation in how far given schedules are relevant for clinical practice. However, the benefit of a SIB based on choline PET seems less than intuitively expected. Only under the

  19. New recommendations for dose equivalent

    International Nuclear Information System (INIS)

    Bengtsson, G.

    1985-01-01

    In its report 39, the International Commission on Radiation Units and Measurements (ICRU), has defined four new quantities for the determination of dose equivalents from external sources: the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent, penetrating and the individual dose equivalent, superficial. The rationale behind these concepts and their practical application are discussed. Reference is made to numerical values of these quantities which will be the subject of a coming publication from the International Commission on Radiological Protection, ICRP. (Author)

  20. Dose assessment in pediatric computerized tomography; Avaliacao de doses em tomografia computadorizada pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Vilarinho, Luisa Maria Auredine Lima

    2004-07-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI{sub w} obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI{sub w} values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI{sub w} . (author)

  1. Low doses effects

    International Nuclear Information System (INIS)

    Tubiana, M.

    1997-01-01

    In this article is asked the question about a possible carcinogens effect of low dose irradiation. With epidemiological data, knowledge about the carcinogenesis, the professor Tubiana explains that in spite of experiments made on thousand or hundred of thousands animals it has not been possible to bring to the fore a carcinogens effect for low doses and then it is not reasonable to believe and let the population believe that low dose irradiation could lead to an increase of neoplasms and from this point of view any hardening of radiation protection standards could in fact, increase anguish about ionizing radiations. (N.C.)

  2. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  3. Synchronized dynamic dose reconstruction

    International Nuclear Information System (INIS)

    Litzenberg, Dale W.; Hadley, Scott W.; Tyagi, Neelam; Balter, James M.; Ten Haken, Randall K.; Chetty, Indrin J.

    2007-01-01

    Variations in target volume position between and during treatment fractions can lead to measurable differences in the dose distribution delivered to each patient. Current methods to estimate the ongoing cumulative delivered dose distribution make idealized assumptions about individual patient motion based on average motions observed in a population of patients. In the delivery of intensity modulated radiation therapy (IMRT) with a multi-leaf collimator (MLC), errors are introduced in both the implementation and delivery processes. In addition, target motion and MLC motion can lead to dosimetric errors from interplay effects. All of these effects may be of clinical importance. Here we present a method to compute delivered dose distributions for each treatment beam and fraction, which explicitly incorporates synchronized real-time patient motion data and real-time fluence and machine configuration data. This synchronized dynamic dose reconstruction method properly accounts for the two primary classes of errors that arise from delivering IMRT with an MLC: (a) Interplay errors between target volume motion and MLC motion, and (b) Implementation errors, such as dropped segments, dose over/under shoot, faulty leaf motors, tongue-and-groove effect, rounded leaf ends, and communications delays. These reconstructed dose fractions can then be combined to produce high-quality determinations of the dose distribution actually received to date, from which individualized adaptive treatment strategies can be determined

  4. Creation and clinical application of real-time dose monitor using dose area product meter

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Uoyama, Yoshinori; Iida, Hiroji; Mizushima, Takashi

    2004-01-01

    The management of patient dose has become more of an issue in recent years. Dose can be determined non-invasively and in real time through the use of a dose area product meter, but it is the area dose value that is obtained. Therefore, we created a program that estimates entrance skin dose (ESD) in real time from area dose values obtained during procedures. We used Microsoft Visual C++ 6.0 (Standard Edition) for the programming language and C language for the programming environment. The value was a maximum 285.4 mGy at ileus tube insertion when measuring ESD for radiography of the digestive organ and non-vascular type interventional radiology (IVR) using the created program and seeking the average according to the procedures. The program that we created can be considered valid for monitoring ESD correctly and in real time. (author)

  5. Does Vertebroplasty Affect Radiation Dose Distribution?: Comparison of Spatial Dose Distributions in a Cement-Injected Vertebra as Calculated by Treatment Planning System and Actual Spatial Dose Distribution

    International Nuclear Information System (INIS)

    Komemushi, A.; Tanigawa, N.; Kariya, Sh.; Yagi, R.; Nakatani, M.; Suzuki, S.; Sano, A.; Ikeda, K.; Utsunomiya, K.; Harima, Y.; Sawada, S.

    2012-01-01

    Purpose. To assess differences in dose distribution of a vertebral body injected with bone cement as calculated by radiation treatment planning system (RTPS) and actual dose distribution. Methods. We prepared two water-equivalent phantoms with cement, and the other two phantoms without cement. The bulk density of the bone cement was imported into RTPS to reduce error from high CT values. A dose distribution map for the phantoms with and without cement was calculated using RTPS with clinical setting and with the bulk density importing. Actual dose distribution was measured by the film density. Dose distribution as calculated by RTPS was compared to the dose distribution measured by the film dosimetry. Results. For the phantom with cement, dose distribution was distorted for the areas corresponding to inside the cement and on the ventral side of the cement. However, dose distribution based on film dosimetry was undistorted behind the cement and dose increases were seen inside cement and around the cement. With the equivalent phantom with bone cement, differences were seen between dose distribution calculated by RTPS and that measured by the film dosimetry. Conclusion. The dose distribution of an area containing bone cement calculated using RTPS differs from actual dose distribution

  6. Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, S.; Nithiananthan, S.; Mirota, D. J.; Uneri, A.; Stayman, J. W.; Zbijewski, W.; Schmidgunst, C.; Kleinszig, G.; Khanna, A. J.; Siewerdsen, J. H. [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 (United States); Department of Computer Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 (United States); Siemens Healthcare XP Division, Erlangen (Germany); Department of Orthopaedic Surgery, Johns Hopkins University, Baltimore, Maryland 21239 (United States); Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 and Department of Computer Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States)

    2011-08-15

    , and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

  7. Impact of Drug Therapy, Radiation Dose, and Dose Rate on Renal Toxicity Following Bone Marrow Transplantation

    International Nuclear Information System (INIS)

    Cheng, Jonathan C.; Schultheiss, Timothy E.; Wong, Jeffrey Y.C.

    2008-01-01

    Purpose: To demonstrate a radiation dose response and to determine the dosimetric and chemotherapeutic factors that influence the incidence of late renal toxicity following total body irradiation (TBI). Methods and Materials: A comprehensive retrospective review was performed of articles reporting late renal toxicity, along with renal dose, fractionation, dose rate, chemotherapy regimens, and potential nephrotoxic agents. In the final analysis, 12 articles (n = 1,108 patients), consisting of 24 distinct TBI/chemotherapy conditioning regimens were included. Regimens were divided into three subgroups: adults (age ≥18 years), children (age <18 years), and mixed population (both adults and children). Multivariate logistic regression was performed to identify dosimetric and chemotherapeutic factors significantly associated with late renal complications. Results: Individual analysis was performed on each population subgroup. For the purely adult population, the only significant variable was total dose. For the mixed population, the significant variables included total dose, dose rate, and the use of fludarabine. For the pediatric population, only the use of cyclosporin or teniposide was significant; no dose response was noted. A logistic model was generated with the exclusion of the pediatric population because of its lack of dose response. This model yielded the following significant variables: total dose, dose rate, and number of fractions. Conclusion: A dose response for renal damage after TBI was identified. Fractionation and low dose rates are factors to consider when delivering TBI to patients undergoing bone marrow transplantation. Drug therapy also has a major impact on kidney function and can modify the dose-response function

  8. Is it sensible to “deform” dose? 3D experimental validation of dose-warping

    International Nuclear Information System (INIS)

    Yeo, U. J.; Taylor, M. L.; Supple, J. R.; Smith, R. L.; Dunn, L.; Kron, T.; Franich, R. D.

    2012-01-01

    Purpose: Strategies for dose accumulation in deforming anatomy are of interest in radiotherapy. Algorithms exist for the deformation of dose based on patient image sets, though these are sometimes contentious because not all such image calculations are constrained by physical laws. While tumor and organ motion has been a key area of study for a considerable amount of time, deformation is of increasing interest. In this work, we demonstrate a full 3D experimental validation of results from a range of dose deformation algorithms available in the public domain. Methods: We recently developed the first tissue-equivalent, full 3D deformable dosimetric phantom—“DEFGEL.” To assess the accuracy of dose-warping based on deformable image registration (DIR), we have measured doses in undeformed and deformed states of the DEFGEL dosimeter and compared these to planned doses and warped doses. In this way we have directly evaluated the accuracy of dose-warping calculations for 11 different algorithms. We have done this for a range of stereotactic irradiation schemes and types and magnitudes of deformation. Results: The original Horn and Schunck algorithm is shown to be the best performing of the 11 algorithms trialled. Comparing measured and dose-warped calculations for this method, it is found that for a 10 × 10 mm 2 square field, γ 3%/3mm = 99.9%; for a 20 × 20 mm 2 cross-shaped field, γ 3%/3mm = 99.1%; and for a multiple dynamic arc (0.413 cm 3 PTV) treatment adapted from a patient treatment plan, γ 3%/3mm = 95%. In each case, the agreement is comparable to—but consistently ∼1% less than—comparison between measured and calculated (planned) dose distributions in the absence of deformation. The magnitude of the deformation, as measured by the largest displacement experienced by any voxel in the volume, has the greatest influence on the accuracy of the warped dose distribution. Considering the square field case, the smallest deformation (∼9 mm) yields

  9. Radiochromic Plastic Films for Accurate Measurement of Radiation Absorbed Dose and Dose Distributions

    DEFF Research Database (Denmark)

    McLaughlin, W. L.; Miller, Arne; Fidan, S.

    1977-01-01

    of dose rate (1–1014 rad s−1). Upon irradiation of the film, the profile of the radiation field is registered as a permanent colored image of the dose distribution. Unlike most other types of dyed plastic dose meters, the optical density produced by irradiation is in most cases stable for periods...... of many polymeric systems in industrial radiation processing. The result is that errors due to energy dependence of response of the radiation sensor are effectively reduced, since the spectral sensitivity of the dose meter matches that of the polymer of interest, over a wide range of photon and electron...

  10. Lateral topography for reducing effective dose in low-dose chest CT.

    Science.gov (United States)

    Bang, Dong-Ho; Lim, Daekeon; Hwang, Wi-Sub; Park, Seong-Hoon; Jeong, Ok-man; Kang, Kyung Wook; Kang, Hohyung

    2013-06-01

    The purposes of this study were to assess radiation exposure during low-dose chest CT by using lateral topography and to compare the lateral topographic findings with findings obtained with anteroposterior topography alone and anteroposterior and lateral topography combined. From November 2011 to February 2012, 210 male subjects were enrolled in the study. Age, weight, and height of the men were recorded. All subjects were placed into one of three subgroups based on the type of topographic image obtained: anteroposterior topography, lateral topography, and both anteroposterior and lateral topography. Imaging was performed with a 128-MDCT scanner. CT, except for topography, was the same for all subjects. A radiologist analyzed each image, recorded scan length, checked for any insufficiencies in the FOV, and calculated the effective radiation dose. One-way analysis of variance and multiple comparisons were used to compare the effective radiation exposure and scan length between groups. The mean scan length in the anteroposterior topography group was significantly greater than that of the lateral topography group and the combined anteroposterior and lateral topography group (p topography group (0.735 ± 0.033 mSv) was significantly lower than that for the anteroposterior topography group (0.763 ± 0.038 mSv) and the combined anteroposterior and lateral topography group (0.773 ± 0.038) (p < 0.001). Lateral topographic low-dose CT was associated with a lower effective radiation dose and scan length than either anteroposterior topographic low-dose chest CT or low-dose chest CT with both anteroposterior and lateral topograms.

  11. Measured dose to ovaries and testes from Hodgkin's fields and determination of genetically significant dose

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.; Cumberlin, R.

    1993-01-01

    The purpose of this study was to determine the genetically significant dose from therapeutic radiation exposure with Hodgkin's fields by estimating the doses to ovaries and testes. Phantom measurements were performed to verify estimated doses to ovaries and testes from Hodgkin's fields. Thermoluminescent LiF dosimeters (TLD-100) of 1 x 3 x 3 mm 3 dimensions were embedded in phantoms and exposed to standard mantle and paraaortic fields using Co-60, 4 MV, 6 MV, and 10 MV photon beams. The results show that measured doses to ovaries and testes are about two to five times higher than the corresponding graphically estimated doses for Co-60 and 4 MVX photon beams as depicted in ICRP publication 44. In addition, the measured doses to ovaries and testes are about 30% to 65% lower for 10 MV photon beams than for their corresponding Co-60 photon beams. The genetically significant dose from Hodgkin's treatment (less than 0.01 mSv) adds about 4% to the genetically significant dose contribution to medical procedures and adds less than 1% to the genetically significant dose from all sources. Therefore, the consequence to society is considered to be very small. The consequences for the individual patient are, likewise, small. 28 refs., 3 figs., 5 tabs

  12. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  13. We can do better than effective dose for estimating or comparing low-dose radiation risks

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    The effective dose concept was designed to compare the generic risks of exposure to different radiation fields. More commonly these days, it is used to estimate or compare radiation-induced cancer risks. For various reasons, effective dose represents flawed science: for instance, the tissue-specific weighting factors used to calculate effective dose are a subjective mix of different endpoints; and the marked and differing age and gender dependencies for different health detriment endpoints are not taken into account. This paper suggests that effective dose could be replaced with a new quantity, ‘effective risk’, which, like effective dose, is a weighted sum of equivalent doses to different tissues. Unlike effective dose, where the tissue-dependent weighting factors are a set of generic, subjective committee-defined numbers, the weighting factors for effective risk are simply evaluated tissue-specific lifetime cancer risks per unit equivalent dose. Effective risk, which has the potential to be age and gender specific if desired, would perform the same comparative role as effective dose, be just as easy to estimate, be less prone to misuse, be more directly understandable, and would be based on solid science. An added major advantage is that it gives the users some feel for the actual numerical values of the radiation risks they are trying to control.

  14. Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring.

    Science.gov (United States)

    Sailer, Anna M; Vergoossen, Laura; Paulis, Leonie; van Zwam, Willem H; Das, Marco; Wildberger, Joachim E; Jeukens, Cécile R L P N

    2017-11-01

    Radiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions. Medical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1-5th months: Staff did not receive feedback (n = 701) and (2) 6-8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose. Personalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04-0.50) µSv/Gy cm 2 versus (phase 2) 0.08 (0.02-0.24) µSv/Gy cm 2 , p = 0.002]. Personalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.

  15. Health effects of low doses at low dose rates: dose-response relationship modeling in a cohort of workers of the nuclear industry; Effets sanitaires des faibles doses a faibles debits de dose: modelisation de la relation dose-reponse dans une cohorte de travailleurs du nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Metz-Flamant, Camille

    2011-09-19

    The aim of this thesis is to contribute to a better understanding of the health effects of chronic external low doses of ionising radiation. This work is based on the French cohort of CEA-AREVA NC nuclear workers. The mains stages of this thesis were (1) conducting a review of epidemiological studies on nuclear workers, (2) completing the database and performing a descriptive analysis of the cohort, (3) quantifying risk by different statistical methods and (4) modelling the exposure-time-risk relationship. The cohort includes monitored workers employed more than one year between 1950 and 1994 at CEA or AREVA NC companies. Individual annual external exposure, history of work, vital status and causes of death were reconstructed for each worker. Standardized mortality ratios using French national mortality rates as external reference were computed. Exposure-risk analysis was conducted in the cohort using the linear excess relative risk model, based on both Poisson regression and Cox model. Time dependent modifying factors were investigated by adding an interaction term in the model or by using exposure time windows. The cohort includes 36, 769 workers, followed-up until age 60 in average. During the 1968- 2004 period, 5, 443 deaths, 2, 213 cancers, 62 leukemia and 1, 314 cardiovascular diseases were recorded. Among the 57% exposed workers, the mean cumulative dose was 21.5 milli-sieverts (mSv). A strong Healthy Worker Effect is observed in the cohort. Significant elevated risks of pleura cancer and melanoma deaths were observed in the cohort but not associated with dose. No significant association was observed with solid cancers, lung cancer and cardiovascular diseases. A significant dose-response relationship was observed for leukemia excluding chronic lymphatic leukemia, mainly for doses received less than 15 years before and for yearly dose rates higher than 10 mSv. This PhD work contributes to the evaluation of risks associated to chronic external radiation

  16. An environmental dose experiment

    Science.gov (United States)

    Peralta, Luis

    2017-11-01

    Several radiation sources worldwide contribute to the delivered dose to the human population. This radiation also acts as a natural background when detecting radiation, for instance from radioactive sources. In this work a medium-sized plastic scintillation detector is used to evaluate the dose delivered by natural radiation sources. Calibration of the detector involved the use of radioactive sources and Monte Carlo simulation of the energy deposition per disintegration. A measurement of the annual dose due to background radiation to the body was then estimated. A dose value compatible with the value reported by the United Nations Scientific Committee on the Effects of Atomic Radiation was obtained.

  17. An environmental dose experiment

    International Nuclear Information System (INIS)

    Peralta, Luis

    2017-01-01

    Several radiation sources worldwide contribute to the delivered dose to the human population. This radiation also acts as a natural background when detecting radiation, for instance from radioactive sources. In this work a medium-sized plastic scintillation detector is used to evaluate the dose delivered by natural radiation sources. Calibration of the detector involved the use of radioactive sources and Monte Carlo simulation of the energy deposition per disintegration. A measurement of the annual dose due to background radiation to the body was then estimated. A dose value compatible with the value reported by the United Nations Scientific Committee on the Effects of Atomic Radiation was obtained. (paper)

  18. Radiation dose in vertebroplasty

    International Nuclear Information System (INIS)

    Mehdizade, A.; Lovblad, K.O.; Wilhelm, K.E.; Somon, T.; Wetzel, S.G.; Kelekis, A.D.; Yilmaz, H.; Abdo, G.; Martin, J.B.; Viera, J.M.; Ruefenacht, D.A.

    2004-01-01

    We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements. (orig.)

  19. Multiple anatomy optimization of accumulated dose

    International Nuclear Information System (INIS)

    Watkins, W. Tyler; Siebers, Jeffrey V.; Moore, Joseph A.; Gordon, James; Hugo, Geoffrey D.

    2014-01-01

    Purpose: To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. Methods: MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. Results: By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. Conclusions: MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated

  20. Multiple anatomy optimization of accumulated dose

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, W. Tyler, E-mail: watkinswt@virginia.edu; Siebers, Jeffrey V. [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia 22908 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Moore, Joseph A. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland 21231 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Gordon, James [Henry Ford Health System, Detroit, Michigan 48202 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Hugo, Geoffrey D. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States)

    2014-11-01

    Purpose: To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. Methods: MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. Results: By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. Conclusions: MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated.

  1. Multiple anatomy optimization of accumulated dose.

    Science.gov (United States)

    Watkins, W Tyler; Moore, Joseph A; Gordon, James; Hugo, Geoffrey D; Siebers, Jeffrey V

    2014-11-01

    To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated.

  2. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  3. Registration of radiation doses

    International Nuclear Information System (INIS)

    2000-02-01

    In Finland the Radiation and Nuclear Safety Authority (STUK) is maintaining the register (called Dose Register) of the radiation exposure of occupationally exposed workers in order to ensure compliance with the principles of optimisation and individual protection. The guide contains a description of the Dose Register and specifies the responsibilities of the party running a radiation practice to report the relevant information to the Dose Register

  4. Radiation absorbed doses in cephalography

    International Nuclear Information System (INIS)

    Eliasson, S.; Julin, P.; Richter, S.; Stenstroem, B.

    1984-01-01

    Radiation absorbed doses to different organs in the head and neck region in lateral (LAT) and postero-anterior (PA) cephalography were investigated. The doses were measured by thermoluminescence dosimeters (TLD) on a tissue equivalent phantom head. Lanthanide screens in speed group 4 were used at 90 and 85 k Vp. A near-focus aluminium dodger was used and the radiation beam was collimated strictly to the face. The maximum entrance dose from LAT was 0.25 mGy and 0.42 mGy from a PA exposure. The doses to the salivary glands ranged between 0.2 and 0.02 mGy at LAT and between 0.15 and 0.04 mGy at PA exposures. The average thyroid gland dose without any shielding was 0.11 mGy (LAT) and 0.06 mGy (PA). When a dodger was used the dose was reduced to 0.07 mGy (LAT). If the thyroid gland was sheilded off, the dose was further reduced to 0.01 mGy and if the thyroid region was collimated out of the primary radiation field the dose was reduced to only 0.005 mGy. (authors)

  5. Identification of dose-reduction techniques for BWR and PWR repetitive high-dose jobs

    International Nuclear Information System (INIS)

    Dionne, B.J.; Baum, J.W.

    1984-01-01

    As a result of concern about the apparent increase in collective radiation dose to workers at nuclear power plants, this project will provide information to industry in preplanning for radiation protection during maintenance operations. This study identifies Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) repetitive jobs, and respective collective dose trends and dose reduction techniques. 3 references, 2 tables

  6. ICRU reference dose in an era of intensity-modulated radiation therapy clinical trials: Correlation with planning target volume mean dose and suitability for intensity-modulated radiation therapy dose prescription

    International Nuclear Information System (INIS)

    Yaparpalvi, Ravindra; Hong, Linda; Mah, Dennis; Shen Jin; Mutyala, Subhakar; Spierer, Marnee; Garg, Madhur; Guha, Chandan; Kalnicki, Shalom

    2008-01-01

    Background and Purpose: IMRT clinical trials lack dose prescription and specification standards similar to ICRU standards for two- and three-dimensional external beam planning. In this study, we analyzed dose distributions for patients whose treatment plans incorporated IMRT, and compared the dose determined at the ICRU reference point to the PTV doses determined from dose-volume histograms. Additionally, we evaluated if ICRU reference type single-point dose prescriptions are suitable for IMRT dose prescriptions. Materials and methods: For this study, IMRT plans of 117 patients treated at our institution were randomly selected and analyzed. The treatment plans were clinically applied to the following disease sites: abdominal (11), anal (10), brain (11), gynecological (15), head and neck (25), lung (15), male pelvis (10) and prostate (20). The ICRU reference point was located in each treatment plan following ICRU Report 50 guidelines. The reference point was placed in the central part of the PTV and at or near the isocenter. In each case, the dose was calculated and recorded to this point. For each patient - volume and dose (PTV, PTV mean, median and modal) information was extracted from the planned dose-volume histogram. Results: The ICRU reference dose vs PTV mean dose relationship in IMRT exhibited a weak positive association (Pearson correlation coefficient 0.63). In approximately 65% of the cases studied, dose at the ICRU reference point was greater than the corresponding PTV mean dose. The dose difference between ICRU reference and PTV mean doses was ≤2% in approximately 79% of the cases studied (average 1.21% (±1.55), range -4% to +4%). Paired t-test analyses showed that the ICRU reference doses and PTV median doses were statistically similar (p = 0.42). The magnitude of PTV did not influence the difference between ICRU reference and PTV mean doses. Conclusions: The general relationship between ICRU reference and PTV mean doses in IMRT is similar to that

  7. Occupational dose trends in Tanzania

    International Nuclear Information System (INIS)

    Muhogora, W.E.; Nyanda, A.M.; Ngaile, J.E.; Lema, U.S.

    1998-01-01

    This paper describes the present status of occupational radiation exposure of monitored workers in Tanzania from 1986 to 1997. The analysis of dose records observes over this period, a fluctuating trend both in the individual and collective doses. The trend is more related to the fluctuations of the number of radiation workers than to the possible radiation safety changes of the working conditions. It has been found that, the maximum annual dose for the worker in all work categories was about 18 mSv y -1 . This suggests that the occupational radiation exposure in all practices satisfies the current dose limitation system. The national exposure summary shows that, the highest collective dose of 12.8 man-Sv which is 90% of the total collective dose, was due to medical applications. The applications in industry and research had a contribution of nearly 0.8 and 0.7 man-Sv respectively. From the professional point of view, the medical diagnostic radiographers received the highest collective dose of 11.2 man-Sv. Although the medical physicists recorded the minimum collective dose of nearly 0.07 man-Sv, the data shows that this profession received the highest mean dose of about 33 mSv in 12 years. Some achievements of the personnel monitoring services and suggestions for future improvement are pointed out. (author)

  8. Simulation of dose reduction in tomosynthesis

    International Nuclear Information System (INIS)

    Svalkvist, Angelica; Baath, Magnus

    2010-01-01

    Purpose: Methods for simulating dose reduction are valuable tools in the work of optimizing radiographic examinations. Using such methods, clinical images can be simulated to have been collected at other, lower, dose levels without the need of additional patient exposure. A recent technology introduced to healthcare that needs optimization is tomosynthesis, where a number of low-dose projection images collected at different angles is used to reconstruct section images of an imaged object. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems, suitable for tomosynthesis. Methods: The developed method uses information about the noise power spectrum (NPS) at the original dose level and the simulated dose level to create a noise image that is added to the original image to produce an image that has the same noise properties as an image actually collected at the simulated dose level. As the detective quantum efficiency (DQE) of digital detectors operating at the low dose levels used for tomosynthesis may show a strong dependency on the dose level, it is important that a method for simulating dose reduction for tomosynthesis takes this dependency into account. By applying an experimentally determined relationship between pixel mean and pixel variance, variations in both dose and DQE in relevant dose ranges are taken into account. Results: The developed method was tested on a chest tomosynthesis system and was shown to produce NPS of simulated dose-reduced projection images that agreed well with the NPS of images actually collected at the simulated dose level. The simulated dose reduction method was also applied to tomosynthesis examinations of an anthropomorphic chest phantom, and the obtained noise in the reconstructed section images was very similar to that of an examination actually performed at the simulated dose level. Conclusions: In conclusion, the present article describes a method for simulating dose

  9. Organ doses and effective doses in some medical and industrial applications

    International Nuclear Information System (INIS)

    Keshavkumar, Biju

    2000-01-01

    The ICRP recommends radiation protection standards for the safe use of radiation and also prescribes the radiation protection quantities and periodically reviews them. In this context, the quantities like organ doses and effective doses are defined by ICRP. In this work we calculate these quantities and hence the conversion functions for the industrial radiation sources and those for CT and diagnostic X-ray exposures. Workers who are occupationally exposed to radiation are regularly monitored to evaluate the radiation dose received by them. It is quite possible that in an accident situation, the worker involved in the accident might not have worn a personal monitor, popularly known as the monitoring badge. In addition, even some non radiation workers (who are obviously not monitored) may also have received exposure. Under these circumstances, the persons involved are interviewed, the accident site inspected, and on the basis of realistic assumptions, the likely doses received by the exposed persons are estimated

  10. Experimental data and dose-response models

    International Nuclear Information System (INIS)

    Ullrich, R.L.

    1985-01-01

    Dose-response relationships for radiation carcinogenesis have been of interest to biologists, modelers, and statisticians for many years. Despite his interest there are few instances in which there are sufficient experimental data to allow the fitting of various dose-response models. In those experimental systems for which data are available the dose-response curves for tumor induction for the various systems cannot be described by a single model. Dose-response models which have been observed following acute exposures to gamma rays include threshold, quadratic, and linear models. Data on sex, age, and environmental influences of dose suggest a strong role of host factors on the dose response. With decreasing dose rate the effectiveness of gamma ray irradiation tends to decrease in essentially every instance. In those cases in which the high dose rate dose response could be described by a quadratic model, the effect of dose rate is consistent with predictions based on radiation effects on the induction of initial events. Whether the underlying reasons for the observed dose-rate effect is a result of effects on the induction of initial events or is due to effects on the subsequent steps in the carcinogenic process is unknown. Information on the dose response for tumor induction for high LET (linear energy transfer) radiations such as neutrons is even more limited. The observed dose and dose rate data for tumor induction following neutron exposure are complex and do not appear to be consistent with predictions based on models for the induction of initial events

  11. Considering job-related doses in Europe

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    As part of its role of safeguarding nuclear workers the Commission of the European Community has created a European data bank on job-related doses. The data bank is intended to correlate jobs and workers doses and is a useful instrument to observe the collected doses of workers in nuclear power plants. Set up in 1980, the database covers doses in PWRs and BWRs. To create it a questionnaire is distributed to plant operators. The database responses provide information on (i) Trends in total collective doses, including those for some ancillary jobs. It is possible to see trends by calendar year and by fuel cycle number. (ii) Other trends such as dose in terms of installed power or dose in terms of power station design. (iii) Dose differences between power stations, normalized against the differences in dose rates. This is only possible for PWRs that monitor dose rates using the EPRI standard monitoring programme. (vi) The relative dose rate in each plant for a defined job. The questionnaire is not perfectly adapted to all the working criteria in nuclear power stations but it is an effective tool for implementing radiation protection. (author)

  12. Low dose radiation enhance the anti-tumor effect of high dose radiation on human glioma cell U251

    International Nuclear Information System (INIS)

    Wang Chang; Wang Guanjun; Tan Yehui; Jiang Hongyu; Li Wei

    2008-01-01

    Objective: To detect the effect on the growth of human glioma cell U251 induced by low dose irradiation and low dose irradiation combined with large dose irradiation. Methods: Human glioma cell line U251 and nude mice carried with human glioma were used. The tumor cells and the mice were treated with low dose, high dose, and low dose combined high dose radiation. Cells growth curve, MTT and flow cytometry were used to detect the proliferation, cell cycle and apoptosis of the cells; and the tumor inhibition rate was used to assess the growth of tumor in vivo. Results: After low dose irradiation, there was no difference between experimental group and control group in cell count, MTT and flow cytometry. Single high dose group and low dose combined high dose group both show significantly the suppressing effect on tumor cells, the apoptosis increased and there was cell cycle blocked in G 2 period, but there was no difference between two groups. In vivo apparent anti-tumor effect in high dose radiation group and the combining group was observed, and that was more significant in the combining group; the prior low dose radiation alleviated the injury of hematological system. There was no difference between single low dose radiation group and control. Conclusions: There is no significant effect on human glioma cell induced by low dose radiation, and low dose radiation could not induce adaptive response. But in vivo experience, low dose radiation could enhance the anti-tumor effect of high dose radiation and alleviated the injury of hematological system. (authors)

  13. Clinical application of a OneDose MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast.

    Science.gov (United States)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs.

  14. Dose banding as an alternative to body surface area-based dosing of chemotherapeutic agents

    NARCIS (Netherlands)

    E. Chatelut (Etienne); M.L. White-Koning (M.); A.H.J. Mathijssen (Ron); F. Puisset (F.); S.D. Baker (Sharyn); A. Sparreboom (Alex)

    2012-01-01

    textabstractBackground: Dose banding is a recently suggested dosing method that uses predefined ranges (bands) of body surface area (BSA) to calculate each patients dose by using a single BSA-value per band. Thus, drugs with sufficient long-term stability can be prepared in advance. The main

  15. Tank Z-361 dose rate calculations

    International Nuclear Information System (INIS)

    Richard, R.F.

    1998-01-01

    Neutron and gamma ray dose rates were calculated above and around the 6-inch riser of tank Z-361 located at the Plutonium Finishing Plant. Dose rates were also determined off of one side of the tank. The largest dose rate 0.029 mrem/h was a gamma ray dose and occurred 76.2 cm (30 in.) directly above the open riser. All other dose rates were negligible. The ANSI/ANS 1991 flux to dose conversion factor for neutrons and photons were used in this analysis. Dose rates are reported in units of mrem/h with the calculated uncertainty shown within the parentheses

  16. Introduction to the new version of the standard DIN 6814, part 3 'dose magnitudes and dose units'

    Energy Technology Data Exchange (ETDEWEB)

    Harder, D

    1985-02-01

    The recent draft of the DIN standard on dose quantities and dose units is presented on original version and explained by the chairman of the Working Comittee Dosimetry. There are important modifications by the introduction of SI units, the new definitions of site dose and individual dose characteristic dose rate and dose rate constant, as well as by corrections of the notions ''secondary electron equilibrium'' and ''free in air''.

  17. Dose assessments for SFR 1

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la

    2008-05-01

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  18. Dose assessments for SFR 1

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)); Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la (Facilia AB, Bromma (Sweden))

    2008-06-15

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  19. Radiation dose monitoring in the clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika [UK Essen (Germany). Radiology

    2017-04-15

    Here we describe the first clinical experiences regarding the use of an automated radiation dose management software to monitor the radiation dose of patients during routine examinations. Many software solutions for monitoring radiation dose have emerged in the last decade. The continuous progress in radiological techniques, new scan features, scanner generations and protocols are the primary challenge for radiation dose monitoring software systems. To simulate valid dose calculations, radiation dose monitoring systems have to follow current trends and stay constantly up-to-date. The dose management software is connected to all devices at our institute and conducts automatic data acquisition and radiation dose calculation. The system incorporates 18 virtual phantoms based on the Cristy phantom family, estimating doses in newborns to adults. Dose calculation relies on a Monte Carlo simulation engine. Our first practical experiences demonstrate that the software is capable of dose estimation in the clinical routine. Its implementation and use have some limitations that can be overcome. The software is promising and allows assessment of radiation doses, like organ and effective doses according to ICRP 60 and ICRP 103, patient radiation dose history and cumulative radiation doses. Furthermore, we are able to determine local diagnostic reference doses. The radiation dose monitoring software systems can facilitate networking between hospitals and radiological departments, thus refining radiation doses and implementing reference doses at substantially lower levels.

  20. Granulocyte-colony stimulating factor in the prevention of postoperative infectious complications and sub-optimal recovery from operation in patients with colorectal cancer and increased preoperative risk (ASA 3 and 4). Protocol of a controlled clinical trial developed by consensus of an international study group. Part three: individual patient, complication algorithm and quality manage.

    NARCIS (Netherlands)

    Stinner, B.; Bauhofer, A.; Lorenz, W.; Rothmund, M.; Plaul, U.; Torossian, A.; Celik, I.; Sitter, H.; Koller, M.; Black, A.; Duda, D.; Encke, A.; Greger, B.; Goor, H. van; Hanisch, E.; Hesterberg, R.; Klose, K.J.; Lacaine, F.; Lorijn, R.H.; Margolis, C.; Neugebauer, E.; Nystrom, P.O.; Reemst, P.H.M.; Schein, M.; Solovera, J.

    2001-01-01

    GENERAL DESIGN: Presentation of a new type of a study protocol for evaluation of the effectiveness of an immune modifier (rhG-CSF, filgrastim): prevention of postoperative infectious complications and of sub-optimal recovery from operation in patients with colorectal cancer and increased

  1. Radiation dose of CT coronary angiography in clinical practice: Objective evaluation of strategies for dose optimization

    International Nuclear Information System (INIS)

    Yerramasu, Ajay; Venuraju, Shreenidhi; Atwal, Satvir; Goodman, Dennis; Lipkin, David; Lahiri, Avijit

    2012-01-01

    Background: CT coronary angiography (CTCA) is an evolving modality for the diagnosis of coronary artery disease. Radiation burden associated with CTCA has been a major concern in the wider application of this technique. It is important to reduce the radiation dose without compromising the image quality. Objectives: To estimate the radiation dose of CTCA in clinical practice and evaluate the effect of dose-saving algorithms on radiation dose and image quality. Methods: Effective radiation dose was measured from the dose-length product in 616 consecutive patients (mean age 58 ± 12 years; 70% males) who underwent clinically indicated CTCA at our institution over 1 year. Image quality was assessed subjectively using a 4-point scale and objectively by measuring the signal- and contrast-to-noise ratios in the coronary arteries. Multivariate linear regression analysis was used to identify factors independently associated with radiation dose. Results: Mean effective radiation dose of CTCA was 6.6 ± 3.3 mSv. Radiation dose was significantly reduced by dose saving algorithms such as 100 kV imaging (−47%; 95% CI, −44% to −50%), prospective gating (−35%; 95% CI, −29% to −40%) and ECG controlled tube current modulation (−23%; 95% CI, −9% to −34%). None of the dose saving algorithms were associated with a significant reduction in mean image quality or the frequency of diagnostic scans (P = non-significant for all comparisons). Conclusion: Careful application of radiation-dose saving algorithms in appropriately selected patients can reduce the radiation burden of CTCA significantly, without compromising the image quality.

  2. Management of pediatric radiation dose using Philips fluoroscopy systems DoseWise: perfect image, perfect sense

    International Nuclear Information System (INIS)

    Stueve, Dick

    2006-01-01

    Although image quality (IQ) is the ultimate goal for accurate diagnosis and treatment, minimizing radiation dose is equally important. This is especially true when pediatric patients are examined, because their sensitivity to radiation-induced cancer is two to three times greater than that of adults. DoseWise is an ALARA-based philosophy within Philips Medical Systems that is active at every level of product design. It encompasses a set of techniques, programs and practices that ensures optimal IQ while protecting people in the X-ray environments. DoseWise methods include management of the X-ray beam, less radiation-on time and more dose information for the operator. Smart beam management provides automatic customization of the X-ray beam spectrum, shape, and pulse frequency. The Philips-patented grid-controlled fluoroscopy (GCF) provides grid switching of the X-ray beam in the X-ray tube instead of the traditional generator switching method. In the examination of pediatric patients, DoseWise technology has been scientifically documented to reduce radiation dose to <10% of the dose of traditional continuous fluoroscopy systems. The result is improved IQ at a significantly lower effective dose, which contributes to the safety of patients and staff. (orig.)

  3. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  4. Spine stereotactic body radiation therapy plans: Achieving dose coverage, conformity, and dose falloff

    International Nuclear Information System (INIS)

    Hong, Linda X.; Shankar, Viswanathan; Shen, Jin; Kuo, Hsiang-Chi; Mynampati, Dinesh; Yaparpalvi, Ravindra; Goddard, Lee; Basavatia, Amar; Fox, Jana; Garg, Madhur; Kalnicki, Shalom; Tomé, Wolfgang A.

    2015-01-01

    We report our experience of establishing planning objectives to achieve dose coverage, conformity, and dose falloff for spine stereotactic body radiation therapy (SBRT) plans. Patients with spine lesions were treated using SBRT in our institution since September 2009. Since September 2011, we established the following planning objectives for our SBRT spine plans in addition to the cord dose constraints: (1) dose coverage—prescription dose (PD) to cover at least 95% planning target volume (PTV) and 90% PD to cover at least 99% PTV; (2) conformity index (CI)—ratio of prescription isodose volume (PIV) to the PTV < 1.2; (3) dose falloff—ratio of 50% PIV to the PTV (R 50% ); (4) and maximum dose in percentage of PD at 2 cm from PTV in any direction (D 2cm ) to follow Radiation Therapy Oncology Group (RTOG) 0915. We have retrospectively reviewed 66 separate spine lesions treated between September 2009 and December 2012 (31 treated before September 2011 [group 1] and 35 treated after [group 2]). The χ 2 test was used to examine the difference in parameters between groups. The PTV V 100% PD ≥ 95% objective was met in 29.0% of group 1 vs 91.4% of group 2 (p < 0.01) plans. The PTV V 90% PD ≥ 99% objective was met in 38.7% of group 1 vs 88.6% of group 2 (p < 0.01) plans. Overall, 4 plans in group 1 had CI > 1.2 vs none in group 2 (p = 0.04). For D 2cm , 48.3% plans yielded a minor violation of the objectives and 16.1% a major violation for group 1, whereas 17.1% exhibited a minor violation and 2.9% a major violation for group 2 (p < 0.01). Spine SBRT plans can be improved on dose coverage, conformity, and dose falloff employing a combination of RTOG spine and lung SBRT protocol planning objectives

  5. Spine stereotactic body radiation therapy plans: Achieving dose coverage, conformity, and dose falloff

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Linda X., E-mail: lhong0812@gmail.com [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, NY (United States); Shankar, Viswanathan [Department of Epidemiology and Population Health, Albert Einstein College of Medicine, Bronx, NY (United States); Shen, Jin [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Kuo, Hsiang-Chi [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, NY (United States); Mynampati, Dinesh [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Yaparpalvi, Ravindra [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, NY (United States); Goddard, Lee [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Basavatia, Amar; Fox, Jana; Garg, Madhur; Kalnicki, Shalom; Tomé, Wolfgang A. [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, NY (United States)

    2015-10-01

    We report our experience of establishing planning objectives to achieve dose coverage, conformity, and dose falloff for spine stereotactic body radiation therapy (SBRT) plans. Patients with spine lesions were treated using SBRT in our institution since September 2009. Since September 2011, we established the following planning objectives for our SBRT spine plans in addition to the cord dose constraints: (1) dose coverage—prescription dose (PD) to cover at least 95% planning target volume (PTV) and 90% PD to cover at least 99% PTV; (2) conformity index (CI)—ratio of prescription isodose volume (PIV) to the PTV < 1.2; (3) dose falloff—ratio of 50% PIV to the PTV (R{sub 50%}); (4) and maximum dose in percentage of PD at 2 cm from PTV in any direction (D{sub 2cm}) to follow Radiation Therapy Oncology Group (RTOG) 0915. We have retrospectively reviewed 66 separate spine lesions treated between September 2009 and December 2012 (31 treated before September 2011 [group 1] and 35 treated after [group 2]). The χ{sup 2} test was used to examine the difference in parameters between groups. The PTV V{sub 100%} {sub PD} ≥ 95% objective was met in 29.0% of group 1 vs 91.4% of group 2 (p < 0.01) plans. The PTV V{sub 90%} {sub PD} ≥ 99% objective was met in 38.7% of group 1 vs 88.6% of group 2 (p < 0.01) plans. Overall, 4 plans in group 1 had CI > 1.2 vs none in group 2 (p = 0.04). For D{sub 2cm}, 48.3% plans yielded a minor violation of the objectives and 16.1% a major violation for group 1, whereas 17.1% exhibited a minor violation and 2.9% a major violation for group 2 (p < 0.01). Spine SBRT plans can be improved on dose coverage, conformity, and dose falloff employing a combination of RTOG spine and lung SBRT protocol planning objectives.

  6. Doses from radioactive methane

    International Nuclear Information System (INIS)

    Phipps, A.W.; Kendall, G.M.; Fell, T.P.; Harrison, J.D.

    1990-01-01

    A possible radiation hazard arises from exposure to methane labelled with either a 3 H or a 14 C nuclide. This radioactive methane could be released from a variety of sources, e.g. land burial sites containing radioactive waste. Standard assumptions adopted for vapours would not apply to an inert alkane like methane. This paper discusses mechanisms by which radioactive methane would irradiate tissues and provides estimates of doses. Data on skin thickness and metabolism of methane are discussed with reference to these mechanisms. It is found that doses are dominated by dose from the small fraction of methane which is inhaled and metabolised. This component of dose has been calculated under rather conservative assumptions. (author)

  7. Irradiation dose of cosmonauts

    International Nuclear Information System (INIS)

    Makra, Zs.

    1978-01-01

    The results obtained by determining the irradiation dose during the spaceflights of Apollo as well as the Sojouz-3 and Sojouz-9 spacecrafts have been compared in the form of tables. In case of Apollo astronauts the irradiation dose was determined by two methods and its sources were also pointed out, in tables. During Sojouz spacetravels the cosmonauts were exposed to a negligible dose. In spite of this fact the radiation danger is considerable. The small irradiation doses noticed so far are due to the fact that during the spaceflights there was no big proturberance. However, during the future long-range spacetravels a better radiation shielding than the one used up to now will be necessary. (P.J.)

  8. Antipsychotic dose equivalents and dose-years: a standardized method for comparing exposure to different drugs.

    Science.gov (United States)

    Andreasen, Nancy C; Pressler, Marcus; Nopoulos, Peg; Miller, Del; Ho, Beng-Choon

    2010-02-01

    A standardized quantitative method for comparing dosages of different drugs is a useful tool for designing clinical trials and for examining the effects of long-term medication side effects such as tardive dyskinesia. Such a method requires establishing dose equivalents. An expert consensus group has published charts of equivalent doses for various antipsychotic medications for first- and second-generation medications. These charts were used in this study. Regression was used to compare each drug in the experts' charts to chlorpromazine and haloperidol and to create formulas for each relationship. The formulas were solved for chlorpromazine 100 mg and haloperidol 2 mg to derive new chlorpromazine and haloperidol equivalents. The formulas were incorporated into our definition of dose-years such that 100 mg/day of chlorpromazine equivalent or 2 mg/day of haloperidol equivalent taken for 1 year is equal to one dose-year. All comparisons to chlorpromazine and haloperidol were highly linear with R(2) values greater than .9. A power transformation further improved linearity. By deriving a unique formula that converts doses to chlorpromazine or haloperidol equivalents, we can compare otherwise dissimilar drugs. These equivalents can be multiplied by the time an individual has been on a given dose to derive a cumulative value measured in dose-years in the form of (chlorpromazine equivalent in mg) x (time on dose measured in years). After each dose has been converted to dose-years, the results can be summed to provide a cumulative quantitative measure of lifetime exposure. Copyright 2010 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  9. Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.

    Science.gov (United States)

    Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T

    2017-12-01

    The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.

  10. Cocoa agroforestry is less resilient to sub-optimal and extreme climate than cocoa in full sun.

    Science.gov (United States)

    Abdulai, Issaka; Vaast, Philippe; Hoffmann, Munir P; Asare, Richard; Jassogne, Laurence; Van Asten, Piet; Rötter, Reimund P; Graefe, Sophie

    2018-01-01

    Cocoa agroforestry is perceived as potential adaptation strategy to sub-optimal or adverse environmental conditions such as drought. We tested this strategy over wet, dry and extremely dry periods comparing cocoa in full sun with agroforestry systems: shaded by (i) a leguminous tree species, Albizia ferruginea and (ii) Antiaris toxicaria, the most common shade tree species in the region. We monitored micro-climate, sap flux density, throughfall, and soil water content from November 2014 to March 2016 at the forest-savannah transition zone of Ghana with climate and drought events during the study period serving as proxy for projected future climatic conditions in marginal cocoa cultivation areas of West Africa. Combined transpiration of cocoa and shade trees was significantly higher than cocoa in full sun during wet and dry periods. During wet period, transpiration rate of cocoa plants shaded by A. ferruginea was significantly lower than cocoa under A. toxicaria and full sun. During the extreme drought of 2015/16, all cocoa plants under A. ferruginea died. Cocoa plants under A. toxicaria suffered 77% mortality and massive stress with significantly reduced sap flux density of 115 g cm -2  day -1 , whereas cocoa in full sun maintained higher sap flux density of 170 g cm -2  day -1 . Moreover, cocoa sap flux recovery after the extreme drought was significantly higher in full sun (163 g cm -2  day -1 ) than under A. toxicaria (37 g cm -2  day -1 ). Soil water content in full sun was higher than in shaded systems suggesting that cocoa mortality in the shaded systems was linked to strong competition for soil water. The present results have major implications for cocoa cultivation under climate change. Promoting shade cocoa agroforestry as drought resilient system especially under climate change needs to be carefully reconsidered as shade tree species such as the recommended leguminous A. ferruginea constitute major risk to cocoa functioning under

  11. Spiral CT and radiation dose

    International Nuclear Information System (INIS)

    Imhof, H.; Schibany, N.; Ba-Ssalamah, A.; Czerny, C.; Hojreh, A.; Kainberger, F.; Krestan, C.; Kudler, H.; Noebauer, I.; Nowotny, R.

    2003-01-01

    Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers--patients and medical doctors who are non-radiologists--that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information

  12. A patient dose survey for femoral arteriogram diagnostic radiographic examinations using a dose-area product meter

    International Nuclear Information System (INIS)

    Thwaites, J.H.; Rafferty, M.W.; Gray, N.; Black, J.; Stock, B.

    1996-01-01

    A patient dose survey was carried out for femoral arteriogram procedures at the Sir Charles Gairdner Hospital. The procedure involves fluoroscopy to the pelvic region to locate a guide wire and catheter, followed by a series of radiographs extending from the pelvic area to the feet to form a collage image of the entire arterial system. Radiographs are taken whilst a bolus of contrast media is injected into the arterial system. A dose-area product meter was used to determine the dose-area product delivered to patients. Radiographic and patient details were logged with dose-area product for each part of each procedure. Mean energy imparted, mean effective dose and effective dose equivalent are calculated for the examinations. Calculated effective doses are shown to produce results consistent with those of other authors. We present a method for dealing with a complex radiographic procedure including multiple radiographs and fluoroscopy in an attempt to provide a simple way of calculating effective dose from which a general risk factor can be determined. The effective dose varies considerably from examination to examination due to the large range in the number of radiographs taken in any one procedure. A useful index can be obtained by logging the number of radiographs in each region, and fluoroscopy time, from which the effective dose may be easily calculated. These measurements extend a continuing survey of doses for common diagnostic radiographic examinations which previously included the simple examinations: lumbar spine, abdoment and pelvis. (author)

  13. Dose Reduction Techniques

    International Nuclear Information System (INIS)

    WAGGONER, L.O.

    2000-01-01

    As radiation safety specialists, one of the things we are required to do is evaluate tools, equipment, materials and work practices and decide whether the use of these products or work practices will reduce radiation dose or risk to the environment. There is a tendency for many workers that work with radioactive material to accomplish radiological work the same way they have always done it rather than look for new technology or change their work practices. New technology is being developed all the time that can make radiological work easier and result in less radiation dose to the worker or reduce the possibility that contamination will be spread to the environment. As we discuss the various tools and techniques that reduce radiation dose, keep in mind that the radiological controls should be reasonable. We can not always get the dose to zero, so we must try to accomplish the work efficiently and cost-effectively. There are times we may have to accept there is only so much you can do. The goal is to do the smart things that protect the worker but do not hinder him while the task is being accomplished. In addition, we should not demand that large amounts of money be spent for equipment that has marginal value in order to save a few millirem. We have broken the handout into sections that should simplify the presentation. Time, distance, shielding, and source reduction are methods used to reduce dose and are covered in Part I on work execution. We then look at operational considerations, radiological design parameters, and discuss the characteristics of personnel who deal with ALARA. This handout should give you an overview of what it takes to have an effective dose reduction program

  14. Dose Reduction Techniques

    Energy Technology Data Exchange (ETDEWEB)

    WAGGONER, L.O.

    2000-05-16

    As radiation safety specialists, one of the things we are required to do is evaluate tools, equipment, materials and work practices and decide whether the use of these products or work practices will reduce radiation dose or risk to the environment. There is a tendency for many workers that work with radioactive material to accomplish radiological work the same way they have always done it rather than look for new technology or change their work practices. New technology is being developed all the time that can make radiological work easier and result in less radiation dose to the worker or reduce the possibility that contamination will be spread to the environment. As we discuss the various tools and techniques that reduce radiation dose, keep in mind that the radiological controls should be reasonable. We can not always get the dose to zero, so we must try to accomplish the work efficiently and cost-effectively. There are times we may have to accept there is only so much you can do. The goal is to do the smart things that protect the worker but do not hinder him while the task is being accomplished. In addition, we should not demand that large amounts of money be spent for equipment that has marginal value in order to save a few millirem. We have broken the handout into sections that should simplify the presentation. Time, distance, shielding, and source reduction are methods used to reduce dose and are covered in Part I on work execution. We then look at operational considerations, radiological design parameters, and discuss the characteristics of personnel who deal with ALARA. This handout should give you an overview of what it takes to have an effective dose reduction program.

  15. Internal dose estimates

    International Nuclear Information System (INIS)

    Wrenn, M.E.

    1977-01-01

    Internal doses, the procedures for making them and their significance has been reviewed. Effects of uranium, radium, lead-210, polonium-210, thorium in man are analysed based on data from tables and plots. Dosimetry of some ingested nuclides and inhalation dose due to radon-222, radon-220 and their daugther products are discussed [pt

  16. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1987-11-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. Critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 [1] methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed. The effective dose equivalent determined using ICRP-26 methods is significantly smaller than the dose equivalent determined by traditional methods. No existing personnel dosimeter or health physics instrument can determine effective dose equivalent. At the present time, the conversion of dosimeter response to dose equivalent is based on calculations for maximal or ''cap'' values using homogeneous spherical or cylindrical phantoms. The evaluated dose equivalent is, therefore, a poor approximation of the effective dose equivalent as defined by ICRP Publication 26. 3 refs., 2 figs., 1 tab

  17. Modern Radiation Therapy for Hodgkin Lymphoma: Field and Dose Guidelines From the International Lymphoma Radiation Oncology Group (ILROG)

    International Nuclear Information System (INIS)

    Specht, Lena; Yahalom, Joachim; Illidge, Tim; Berthelsen, Anne Kiil; Constine, Louis S.; Eich, Hans Theodor; Girinsky, Theodore; Hoppe, Richard T.; Mauch, Peter; Mikhaeel, N. George; Ng, Andrea

    2014-01-01

    use of ISRT has not yet been validated in a formal study, it is more conservative than INRT, accounting for suboptimal information and appropriately designed for safe local disease control. The goal of modern smaller field radiation therapy is to reduce both treatment volume and treatment dose while maintaining efficacy and minimizing acute and late sequelae. This review is a consensus of the International Lymphoma Radiation Oncology Group (ILROG) Steering Committee regarding the modern approach to RT in the treatment of HL, outlining a new concept of ISRT in which reduced treatment volumes are planned for the effective control of involved sites of HL. Nodal and extranodal non-Hodgkin lymphomas (NHL) are covered separately by ILROG guidelines

  18. Eye lens dosimetry in interventional cardiology: Results of staff dose measurements and link to patient dose levels

    International Nuclear Information System (INIS)

    Antic, V.; Ciraj-Bjelac, O.; Rehani, M.; Aleksandric, S.; Arandjic, D.; Ostojic, M.

    2013-01-01

    Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in terms of Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 mSv for the first operator, 33 mSv for the second operator/nurse and 12 mSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 mSv Gy -1 cm -2 for the first operator, 0.33 mSv Gy -1 cm -2 for the second operator/nurse and 0.16 mSv Gy -1 cm -2 for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practice and may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values. (authors)

  19. Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method

    Energy Technology Data Exchange (ETDEWEB)

    Larson, David B. [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2014-10-15

    The principle of ALARA (dose as low as reasonably achievable) calls for dose optimization rather than dose reduction, per se. Optimization of CT radiation dose is accomplished by producing images of acceptable diagnostic image quality using the lowest dose method available. Because it is image quality that constrains the dose, CT dose optimization is primarily a problem of image quality rather than radiation dose. Therefore, the primary focus in CT radiation dose optimization should be on image quality. However, no reliable direct measure of image quality has been developed for routine clinical practice. Until such measures become available, size-specific dose estimates (SSDE) can be used as a reasonable image-quality estimate. The SSDE method of radiation dose optimization for CT abdomen and pelvis consists of plotting SSDE for a sample of examinations as a function of patient size, establishing an SSDE threshold curve based on radiologists' assessment of image quality, and modifying protocols to consistently produce doses that are slightly above the threshold SSDE curve. Challenges in operationalizing CT radiation dose optimization include data gathering and monitoring, managing the complexities of the numerous protocols, scanners and operators, and understanding the relationship of the automated tube current modulation (ATCM) parameters to image quality. Because CT manufacturers currently maintain their ATCM algorithms as secret for proprietary reasons, prospective modeling of SSDE for patient populations is not possible without reverse engineering the ATCM algorithm and, hence, optimization by this method requires a trial-and-error approach. (orig.)

  20. Dose Reduction Techniques

    CERN Document Server

    Waggoner, L O

    2000-01-01

    As radiation safety specialists, one of the things we are required to do is evaluate tools, equipment, materials and work practices and decide whether the use of these products or work practices will reduce radiation dose or risk to the environment. There is a tendency for many workers that work with radioactive material to accomplish radiological work the same way they have always done it rather than look for new technology or change their work practices. New technology is being developed all the time that can make radiological work easier and result in less radiation dose to the worker or reduce the possibility that contamination will be spread to the environment. As we discuss the various tools and techniques that reduce radiation dose, keep in mind that the radiological controls should be reasonable. We can not always get the dose to zero, so we must try to accomplish the work efficiently and cost-effectively. There are times we may have to accept there is only so much you can do. The goal is to do the sm...