WorldWideScience

Sample records for submersible pumping systems

  1. Submersible pumping system with heat transfer mechanism

    Science.gov (United States)

    Hunt, Daniel Francis Alan; Prenger, F. Coyne; Hill, Dallas D; Jankowski, Todd Andrew

    2014-04-15

    A submersible pumping system for downhole use in extracting fluids containing hydrocarbons from a well. In one embodiment, the pumping system comprises a rotary induction motor, a motor casing, one or more pump stages, and a cooling system. The rotary induction motor rotates a shaft about a longitudinal axis of rotation. The motor casing houses the rotary induction motor such that the rotary induction motor is held in fluid isolation from the fluid being extracted. The pump stages are attached to the shaft outside of the motor casing, and are configured to impart fluid being extracted from the well with an increased pressure. The cooling system is disposed at least partially within the motor casing, and transfers heat generated by operation of the rotary induction motor out of the motor casing.

  2. Performance evaluation of a transformerless multiphase electric submersible pump system

    Directory of Open Access Journals (Sweden)

    Ahmed A. Hakeem

    2014-08-01

    Full Text Available Using of low-voltage variable-frequency drive followed by a step-up transformer is the most preferable way to feed an electrical submersible pump motor. The existence of long feeder between the motor and drive systems usually causes over-voltage problems because of the travelling wave phenomenon, which makes the employment of filter networks on the motor or inverter terminals mandatory. The so-called boost-inverter inherently can solve this problem with filter-less operation as it offers a direct sinusoidal output voltage. As boost inverters have voltage boosting capability, it can provide a transformer-less operation as well. This study investigates the performance of a five-phase modular winding induction machine fed from a boost-inverter through a long feeder. A simulation study using a 1000 Hp system and experimental investigation on a 1 Hp prototype machine are used to support the presented approach.

  3. Optimization of operating costs in managing electrical submersible pumping systems

    Science.gov (United States)

    Kozlov, V. V.; Speranskaya, N. I.

    2017-10-01

    Using the methods of analysis, the task of minimizing the specific operating costs for oil production by submersible ESP units was formalized. The analysis of the multidimensional parameter space of the “ESP-well” system made it possible to isolate the vector of controlled parameters, determine the range of admissible parameters, and also to simplify the problem of finding an extremum up to the three-dimensional case. An application of the method of Lagrange multipliers to the solution of the problem is considered.

  4. Dynamic Modeling and Simulation of Deep Geothermal Electric Submersible Pumping Systems

    OpenAIRE

    Julian Kullick; Hackl, Christoph M.

    2017-01-01

    Deep geothermal energy systems employ electric submersible pumps (ESPs) in order to lift geothermal fluid from the production well to the surface. However, rough downhole conditions and high flow rates impose heavy strain on the components, leading to frequent failures of the pump system. As downhole sensor data is limited and often unrealible, a detailed and dynamical model system will serve as basis for deeper understanding and analysis of the overall system behavior. Furthermore, it allows...

  5. Dynamic Modeling and Simulation of Deep Geothermal Electric Submersible Pumping Systems

    Directory of Open Access Journals (Sweden)

    Julian Kullick

    2017-10-01

    Full Text Available Deep geothermal energy systems employ electric submersible pumps (ESPs in order to lift geothermal fluid from the production well to the surface. However, rough downhole conditions and high flow rates impose heavy strain on the components, leading to frequent failures of the pump system. As downhole sensor data is limited and often unrealible, a detailed and dynamical model system will serve as basis for deeper understanding and analysis of the overall system behavior. Furthermore, it allows to design model-based condition monitoring and fault detection systems, and to improve controls leading to a more robust and efficient operation. In this paper, a detailed state-space model of the complete ESP system is derived, covering the electrical, mechanical and hydraulic subsystems. Based on the derived model, the start-up phase of an exemplary yet realistic ESP system in the Megawatt range—located at a setting depth of 950 m and producing geothermal fluid of 140 ∘ C temperature at a rate of 0.145 m 3 s − 1 —is simulated in MATLAB/Simulink. The simulation results show that the system reaches a stable operating point with realistic values. Furthermore, the effect of self-excitation between the filter capacitor and the motor inductor can clearly be observed. A full set of parameters is provided, allowing for direct model implementation and reproduction of the presented results.

  6. Cooling devices and methods for use with electric submersible pumps

    Energy Technology Data Exchange (ETDEWEB)

    Jankowski, Todd Andrew; Gamboa, Jose A

    2017-10-25

    Cooling devices for use with electric submersible pump motors include a refrigerator attached to the end of the electric submersible pump motor with the evaporator heat exchanger accepting all or a portion of the heat load from the motor. The cooling device can be a self-contained bolt-on unit, so that minimal design changes to existing motors are required.

  7. Cooling devices and methods for use with electric submersible pumps

    Science.gov (United States)

    Jankowski, Todd A; Hill, Dallas D

    2014-12-02

    Cooling devices for use with electric submersible pump motors include a refrigerator attached to the end of the electric submersible pump motor with the evaporator heat exchanger accepting all or a portion of the heat load from the motor. The cooling device can be a self-contained bolt-on unit, so that minimal design changes to existing motors are required.

  8. Testing new submersible pumps for proper sizing and reduced costs

    Energy Technology Data Exchange (ETDEWEB)

    O' Toole, W.P.; O' Brien, J.B.

    1989-02-01

    This paper describes an ongoing program to improve overall submersible pump performance by Thums Long Beach Co., acting as contractor for the City of Long Beach, operator of the Long Beach Unit. Thums Long Beach Co. currently operates 700 submersible pump installations located on four manmade islands and one landfill pier location. The program began with spot testing of submersible pumps for Thums' use. It has evolved to 100% pump testing and the stipulation that only pumps with newly manufactured parts are acceptable. The primary goals of this program are to increase well production and to lower lifting costs. Critical to these goals is increasing the average length of run by using accurate pump-performance data to design equipment and by rejecting defective pumps before they are run. Increased production is realized from better designs. Lower lifting costs result from using more efficient pumps and a reduced frequency of pulling submersible equipment.

  9. Testing new submersible pumps for proper sizing and reduced costs

    Energy Technology Data Exchange (ETDEWEB)

    O' Toole, W.P.; O' Brien, J.B.

    1986-01-01

    This paper describes an ongoing program to improve overall submersible pump performance by Thums Long Beach Company, acting as Contractor of the City of Long Beach, Operator of the Long Beach Unit. Thums Long Beach Company currently operates 700 submersible pump installations located on four man-made islands and one land fill pier location. The program began with spot testing of submersible pumps for Thums' use. It has evolved to 100 percent pump testing and the stipulation that only pumps with newly manufactured parts are acceptable. The primary goals of this program are to increase well production and lower lifting costs. Critical to these goals is increasing the average length of run by using accurate pump performance data to design equipment and by rejecting defective pumps before they are run. Increased production is realized from better designs. Lower lifting costs result from utilizing higher efficiency pumps and a reduced frequency of pulling submersible equipment.

  10. AWWA E102-17 submersible vertical turbine pumps

    CERN Document Server

    2017-01-01

    This standard describes minimum requirements for submersible vertical turbine pumps utilizing a discharge column pipe assembly, 5 hp or larger, used in water service, including materials, design, manufacture, inspection, and testing.

  11. Submersible purification system for radioactive water

    Science.gov (United States)

    Abbott, Michael L.; Lewis, Donald R.

    1989-01-01

    A portable, submersible water purification system for use in a pool of water containing radioactive contamination includes a prefilter for filtering particulates from the water. A resin bed is then provided for removal of remaining dissolved, particulate, organic, and colloidal impurities from the prefiltered water. A sterilizer then sterilizes the water. The prefilter and resin bed are suitably contained and are submerged in the pool. The sterilizer is water tight and located at the surface of the pool. The water is circulated from the pool through the prefilter, resin bed, and sterilizer by suitable pump or the like. In the preferred embodiment, the resin bed is contained within a tank which stands on the bottom of the pool and to which a base mounting the prefilter and pump is attached. An inlet for the pump is provided adjacent the bottom of the pool, while the sterilizer and outlet for the system is located adjacent the top of the pool.

  12. Energy consumption behavior of submersible pumps using in the Barind area of Bangladesh

    Science.gov (United States)

    Haque, M. E.; Islam, M. R.; Masud, M. H.; Ferdous, J.; Haniu, H.

    2017-06-01

    In this work the ground water level and water pumping for irrigation and drinking purposes in Barind area of Bangladesh have been studied. The depth of ground water level remains under 30ft throughout the year that enforcing the use of submersible pumps in most parts of Barind zone. The Barind Multipurpose Development Authority (BMDA) and Rajshahi WASA are the major water supplying authority in the Northern Part of Bangladesh by using 14386 and 87 nos of submersible pumps, respectively. An investigation for the values of life cycle cost elements of submersible pumps has also been carried out. The performance of the pumps running in different sites in Barind area were investigated and compared with the lab test results of new pumps. Energy consumption cost is dominating the life cycle cost of the pumps using in Barind region and improper matching of pump standard running conditions and operation/system requirements are the main causes of lower efficiency. It is found that the efficiency of the running pumps is reduced by 20 - 40% than that of lab test results.

  13. 77 FR 2957 - Application for Manufacturing Authority, Liberty Pumps, Inc. (Submersible and Water Pumps...

    Science.gov (United States)

    2012-01-20

    ... Foreign-Trade Zones Board Application for Manufacturing Authority, Liberty Pumps, Inc. (Submersible and... manufacturing authority on behalf of Liberty Pumps, Inc., located in Bergen, New York. The application was... regulations of the Board (15 CFR part 400). It was formally filed on January 12, 2012. The Liberty Pumps, Inc...

  14. Small, submersible, centrifugal pump for liquid nitrogen

    DEFF Research Database (Denmark)

    Rustad, B.M.; Nielsen, A.; Passell, L.

    1965-01-01

    Full details are given of a pump designed to circulate several liters/min. It can be evacuated before use to exclude oxygen and may be used at pressures of several atmospheres.......Full details are given of a pump designed to circulate several liters/min. It can be evacuated before use to exclude oxygen and may be used at pressures of several atmospheres....

  15. Experimental Problems of New Constructions of Portable Submersible Pumps for Mining with Electric Motor Cooled by Water Jacket

    Directory of Open Access Journals (Sweden)

    Andrzej KORCZAK

    2014-12-01

    Full Text Available The article presents a new construction of a submersible pumping engine where new original solutions in flowing system and control system where introduced It let obtain high efficiency and fulfill user’s expectations. The article also contains experiments of the new pumping engine and their results. The results of numerical analysis of the movement of liquid in flowing channel is described and the analytical characteristics are compared with ones measured in laboratory. The work also presents the problems with constructing, research and certification of new submersible pumping engine which construction fulfils ATEX requirements for machines working in explosive conditions areas

  16. Optimation Pressure Loss to Oil Production System with Electrical Submersible Pump (ESP) at the Well A SW Field Bojonegoro, East Java

    Science.gov (United States)

    Ilmah, A. M.; Hendrajaya, L.

    2017-07-01

    Study about oil and gas well A and SW fields have been conducted in Bojonegoro area, East Java Province. From the research, it is known that one of the constrain in oil and gas production process is a pressure drop, so that is necessary to set Electrical Submersible Pump (ESP) as an artificial lift pump at low pressure wells. It is needed to analyze the production well pressure as an effort to optimize the fluid production. It is in describe to relations between IPR (Inflow Performance Relationship ) curve with TPR (Tubing Performance Relationship), are getting down point cut TPR curve with IPR curve, fluid rate its optimal, so need tubing’s diameter variation and the number of stage pump ESP variation to can the most optimal fluid rate. Produced that to tubing variation are 2,441 ID is 876,729 bpd, 2,991 is 961,197 bpd, 3,476 id is 996, 26 Bpd, while on the number of stage pump esp variation The most high is stage 400 with fluid rate 961,197 by comparison stage 338 it has value fluid rate 921,165 bpd, stage 200 it has fluid rate 827,889 bpd, and stage 169 has fluid rate 774,646 bpd. Of some variation tubing and stage pumps that has the most influence to fluid rate optimalize is the change number of stage pump.

  17. Commercial Submersible Mixing Pump For SRS Tank Waste Removal - 15223

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, Mike [Savannah River Remediation, LLC., Aiken, SC (United States); Herbert, James E. [Savannah River Remediation, LLC., Aiken, SC (United States); Scheele, Patrick W. [Savannah River Remediation, LLC., Aiken, SC (United States)

    2015-01-12

    The Savannah River Site Tank Farms have 45 active underground waste tanks used to store and process nuclear waste materials. There are 4 different tank types, ranging in capacity from 2839 m3 to 4921 m3 (750,000 to 1,300,000 gallons). Eighteen of the tanks are older style and do not meet all current federal standards for secondary containment. The older style tanks are the initial focus of waste removal efforts for tank closure and are referred to as closure tanks. Of the original 51 underground waste tanks, six of the original 24 older style tanks have completed waste removal and are filled with grout. The insoluble waste fraction that resides within most waste tanks at SRS requires vigorous agitation to suspend the solids within the waste liquid in order to transfer this material for eventual processing into glass filled canisters at the Defense Waste Processing Facility (DWPF). SRS suspends the solid waste by use of recirculating mixing pumps. Older style tanks generally have limited riser openings which will not support larger mixing pumps, since the riser access is typically 58.4 cm (23 inches) in diameter. Agitation for these tanks has been provided by four long shafted standard slurry pumps (SLP) powered by an above tank 112KW (150 HP) electric motor. The pump shaft is lubricated and cooled in a pressurized water column that is sealed from the surrounding waste in the tank. Closure of four waste tanks has been accomplished utilizing long shafted pump technology combined with heel removal using multiple technologies. Newer style waste tanks at SRS have larger riser openings, allowing the processing of waste solids to be accomplished with four large diameter SLPs equipped with 224KW (300 HP) motors. These tanks are used to process the waste from closure tanks for DWPF. In addition to the SLPs, a 224KW (300 HP) submersible mixer pump (SMP) has also been developed and deployed within older style tanks. The SMPs are product cooled and

  18. Algorithm to determine electrical submersible pump performance considering temperature changes for viscous crude oils

    Energy Technology Data Exchange (ETDEWEB)

    Valderrama, A. [Petroleos de Venezuela, S.A., Distrito Socialista Tecnologico (Venezuela); Valencia, F. [Petroleos de Venezuela, S.A., Instituto de Tecnologia Venezolana para el Petroleo (Venezuela)

    2011-07-01

    In the heavy oil industry, electrical submersible pumps (ESPs) are used to transfer energy to fluids through stages made up of one impeller and one diffuser. Since liquid temperature increases through the different stages, viscosity might change between the inlet and outlet of the pump, thus affecting performance. The aim of this research was to create an algorithm to determine ESPs' performance curves considering temperature changes through the stages. A computational algorithm was developed and then compared with data collected in a laboratory with a CG2900 ESP. Results confirmed that when the fluid's viscosity is affected by the temperature changes, the stages of multistage pump systems do not have the same performance. Thus the developed algorithm could help production engineers to take viscosity changes into account and optimize the ESP design. This study developed an algorithm to take into account the fluid viscosity changes through pump stages.

  19. Development of LMR Coolant Technology - Development of a submersible-in-pool electromagnetic pump

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sang Hi; Kim, Hee Reyoung; Lee, Sang Don; Seo, Joon Ho [Seoul National University, Seoul (Korea, Republic of); Cho, Su Won [Kyoungki University, Suwon (Korea, Republic of)

    1997-07-15

    A submersible-in-pool type annular linear induction pumps of 60 l/min and 200 l/min, and 600 deg C has been designed with optimum geometrical and operating values found from MHD and circuit analyses reflecting the high-temperature characteristics of pump materials. Through the characteristics analyses inside the narrow flow channel of electromagnetic pump, the distribution of the time-varying flow field is calculated, and magnetic flux and force density are evaluated by end effects of linear induction electromagnetic pump and the instability analyses are carried out introducing one-dimensional linear perturbation. Testing the pump with the flow rate of 60 l/min in the suitably manufactured loop system shows a flow rate of 58 l/min at an input power of 1,377 VA with 60Hz. The design of a scaled-up pump is further taken into account LMR coolant system requiring increased capacity, and a basic analysis is carried out on the pump of 40,000 l/min for KALIMER. The present project contributes to the further design of engineering prototype electromagnetic pumps with higher capacity and to the development of liquid metal reactor with innovative simplicity. 89 refs., 8 tabs., 45 figs. (author)

  20. The power supply system model of the process submersible device with AC power transmission over the cable-rope

    OpenAIRE

    Rulevskiy, V. M.; Bukreev, Viktor Grigorievich; Kuleshova, Elena Olegovna; Shandarova, Elena Borisovna; Shandarov, S.M.; Vasilyeva, Yu. Z.

    2017-01-01

    A practical problem of power supply system modeling for the process submersible device with AC power transmission over the cable-rope was considered. The problem is highly relevant in developing and operation of submersible centrifugal pumps and submersibles. The results of modeling a symmetrical three-phase power supply system and their compliance with the real data are given at the paper. The obtained results in the mathematical and simulation models were similar.

  1. Utilization of computational simulator for comparison of correlations in multiphase flow in ESP (Electrical Submersible Pumping) systems; Utilizacao de simulador computacional para a comparacao das correlacoes de escoamento multifasico em sistemas BCS

    Energy Technology Data Exchange (ETDEWEB)

    Anjos, Roselaine M. dos; Maitelli, Carla Wilza S.P.; Maitelli, Andre L. [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil); Costa, Rutacio O. [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil)

    2012-07-01

    Electrical Submersible Pumping (ESP) is an artificial lifting method which can be used both onshore and offshore for the production of high flow rates of liquid. By using the computational simulator for systems ESP developed by the AUTOPOC/LAUT - UFRN, this work aimed to evaluate empirical correlations for calculation of multiphase flow in tubing typical of artificial lifting systems operating by ESP. The parameters used for evaluating the correlations are some of the dynamic variables of the system such as head that indicates the lifting capacity of the system, the flow rate of fluid in the pump and the discharge pressure at the pump. Five (5) correlations were evaluated, from which only one considered slipping between phases, but does not take into account flow patterns and, four others considering slipping between the phases as well the flow patterns. The simulation results obtained for all these correlations were compared to results from a commercial computational simulator, extensively used in the oil industry. For both simulators, input values and simulation time, were virtually the same. The results showed that the simulator used in this work showed satisfactory performance, since no significant differences from those obtained with the commercial simulator. (author)

  2. Ocean Economy and Fault Diagnosis of Electric Submersible Pump applied in Floating platform

    Directory of Open Access Journals (Sweden)

    Panlong Zhang

    2017-04-01

    Full Text Available Ocean economy plays a crucial role in the strengthening maritime safety industry and in the welfare of human beings. Electric Submersible Pumps (ESP have been widely used in floating platforms on the sea to provide oil for machines. However, the ESP fault may lead to ocean environment pollution, on the other hand, a timely fault diagnosis of ESP can improve the ocean economy. In order to meet the strict regulations of the ocean economy and environmental protection, the fault diagnosis of ESP system has become more and more popular in many countries. The vibration mechanical models of typical faults have been able to successfully diagnose the faults of ESP. And different types of sensors are used to monitor the vibration signal for the signal analysis and fault diagnosis in the ESP system. Meanwhile, physical sensors would increase the fault diagnosis challenge. Nowadays, the method of neural network for the fault diagnosis of ESP has been applied widely, which can diagnose the fault of an electric pump accurately based on the large database. To reduce the number of sensors and to avoid the large database, in this paper, algorithms are designed based on feature extraction to diagnose the fault of the ESP system. Simulation results show that the algorithms can achieve the prospective objectives superbly.

  3. Submersible pumping, Long Beach Unit of East Wilmington Field: A 17-year review

    Energy Technology Data Exchange (ETDEWEB)

    Allis, D.H.; Capps, W.M.

    1983-10-01

    The electric submersible pump was selected as the primary form of lift when Thums Long Beach Company initiated production operations in August 1965. Deviated wells with ever-increasing volumes resulting from water flooding required a flexibility offered by this method of lift. Numerous problems have been solved in 17 years of these operations to provide a respectable run life and continue on a sound economic operational basis.

  4. Submersible pumping--long beach unit of east wilmington field: A 17-year review

    Energy Technology Data Exchange (ETDEWEB)

    Allis, D.H.; Capps, W.M.

    1984-08-01

    The electric submersible pump (ESP) was selected as the primary form of lift when Thums Long Beach Co. initiated production operations in Aug. 1965. Deviated wells with ever increasing volumes resulting from waterflooding required the flexibility offered by this lift method. Many problems have been solved in the 17 years of these operations to provide a respectable run life and a sound economic operational basis.

  5. Submersible pumping, Long Beach unit of East Wilmington field: a 17-year review

    Energy Technology Data Exchange (ETDEWEB)

    Allis, D.H.; Capps, W.M.

    1983-01-01

    The electric submersible pump was selected as the primary form of lift when THUMS Long Beach Co. initiated production operations in Aug. 1965. Deviated wells with ever-increasing volumes resulting from waterflooding required a flexibility offered by this method of lift. Numerous problems have been solved in 17 yr of these operations to provide a respectable run life and continue on a sound economic operational basis.

  6. Electrically heated pipe in pipe combined with electrical submersible pumps for deepwater development

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Sidnei Guerreiro da; Euphemio, Mauro Luiz Lopes [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2008-07-01

    The general trend of deep water and ultra deep water field development is the requirement of highly insulated flow lines, as flow assurance has become one of the major considerations in designing and operating the sub sea system. If not adequately considered in the design phase, it can have significant and unexpected effects to the operational costs, increasing production lost time, decreasing efficiency. In this scenario, the use of pipe in pipe flow lines, with high passive insulation and/ or active heating (called the Electrically Heated Pipe in Pipe - EHPIP), emerges as an attractive method to prevent deposition, especially of waxes and hydrates, by actively maintaining or leading the temperature of the flow line above a critical limit. Besides, the recent heavy oil discoveries in Brazil have encouraged PETROBRAS to move a step forward in the artificial lift design and operation, by the use of Electrical Submersible Pumps (ESP) installed in deep water wells. The combination of EHPIP and ESP are particularly suitable for deep water, high viscosity and long tie back systems, but also can improve oil recovery and production efficiency by allowing the operator to drop down production losses associated Flow Assurance problems. (author)

  7. INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR

    Directory of Open Access Journals (Sweden)

    V.I. Lobov

    2016-06-01

    Full Text Available Purpose. Development of an intensity setter, which in a rational law changes the opening thyristor the voltage regulator and effectively to changing power supply voltage stator windings of the electric pump deepening, ensuring a smooth start in a wide range. Methodology. Electric submersible pump belongs to the small inertia electric, since it is not significant total moment of inertia, not exceeding two moments of inertia of the motor and static moment on the shaft does not exceed forty percent of the nominal torque. For technical requirements that electric acceleration time should have no less than twenty seconds or more. Office starting modes of electric submersible pumps economically justified using thyristor voltage regulator by forming the dial changes the intensity of the necessary legislation in time voltage feeding the stator windings. This ensures a smooth start right rotor of the electric submersible pump. Results. A block diagram of the intensity setter that is: with control unit, two units that form the exponential voltage supply emitter follower and regulatory elements. The mathematical expressions for voltage at the stator windings of the motor, changing exponentially, opening the angle of thyristor power unit thyristor the voltage regulator, which is determined through the initial angle of opening. Provided formula for pick-up voltage and minimum voltage, time constants, which are determined from the basic equations of motion and mechanical characteristics of the electric motor. Analytical investigated by the voltage dependence violation by changing the time constant flowing and growing exhibitor supply voltage stator electric circuit deepening pump. Originality. Proposed in the initial time on the stator windings of the electric pick-up voltage is applied. Under the influence of this voltage, motor rotor begins to accelerate. At the same time, pick-up voltage decreases the minimum startup voltage varies exponentially in which

  8. Maintenance of submersible pumps in the septic tanks: ergonomic and biological risks to the worker.

    Science.gov (United States)

    Mariño, Suzi; Figueiredo, Alex

    2012-01-01

    In this study was observed the maintenance task of submersible pumps septic tanks installed in industrial bathrooms. This maintenance activity operators are exposed to various biological and ergonomic risks. This type of activity requires its great physical performers who are also subject to contact with human waste in the form of liquids, gases and solids. Besides the problems mentioned, are still exposed to high temperatures that can cause diseases such as hyperthermia or heatstroke. These aspects were observed using the ergonomic assessment methodology in order to suggest improvements that are reflected in productivity and employee satisfaction.

  9. Submersible telemetry system downhole unit model for the petroleum industry

    Science.gov (United States)

    Rubtsova, O. O.; Trofimova, E. S.; Ishchenko, A. V.; Cherepanov, A. N.; Danilov, V. Yu.

    2017-09-01

    This article addresses the issue of increasing requirements for the oil industry: the need to develop new wells and control their profitability. The device under consideration (a submersible telemetry system that is capable of measuring well parameters and transferring them via the communication line to the ground based control system) will allow to avoid downtime when it is extracted for indicators check.

  10. Submersible pumps: Energetic efficiency norm; Bombas sumergibles: norma de eficiencia energetica

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R. A.; Buendia Dominguez, E. H. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The Instituto de Investigaciones Electricas (IIE), supporting the Comision Nacional para el Ahorro de Energia (CONAE), has prepared a preliminary project of the norm of energy efficiency for submersible pumps. This document has complied with the necessary formalities for the emission of the norm. This paper presents the results of the analysis of the submersible pumps, the energy savings, as well as the economic evaluation that sustains the norm project, additionally pointing out the environmental impact that will bring along the implantation of the same. [Espanol] El Instituto de Investigaciones Electricas (IIE), apoyando a la Comision Nacional para el Ahorro de Energia (CONAE), ha elaborado el anteproyecto de norma de eficiencia energetica para bombas sumergibles. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma. En el presente articulo se mencionan los resultados del analisis de las bombas sumergibles, los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicandose ademas el impacto ambiental que tendra la implantacion de la misma.

  11. Numerical simulation and performance prediction in multi-stage submersible centrifugal pump

    Science.gov (United States)

    Wang, W. J.; Li, G. D.; Wang, Y.; Cui, Y. R.; Yin, G.; Peng, S.

    2013-12-01

    In order to study the inner flow field of multi-stage submersible centrifugal pump, the model named QD3-60/4-1.1 was selected. Steady turbulence characteristics of impellers, diffusers and return channel were calculated by Fluent software, the SIMPLEC algorithm and RNG κ-ε turbulence model with sliding mesh technology. Then, the distributions of pressure, velocity and Turbulence kinetic energy was obtained and the distributions of velocity field of a channel were analysed. The results show that the static pressure in impeller is increasing with the increasing of radius. The circumferential component of relative velocity is in the opposite direction of impeller rotating. At the same radius, the component value of pressure surface is larger than suction surface. With the increasing of flow rate, absolute velocity and relative velocity flow angle are becoming small, in opposite of the relative velocity and absolute velocity flow angle. The high turbulent zone of impeller is located in the gap of impellers and diffusers. Flow similarity and structure similarity of the multi-stage submersible pump are confirmed.

  12. Critical surface roughness for wall bounded flow of viscous fluids in an electric submersible pump

    Science.gov (United States)

    Deshmukh, Dhairyasheel; Siddique, Md Hamid; Kenyery, Frank; Samad, Abdus

    2017-11-01

    Surface roughness plays a vital role in the performance of an electric submersible pump (ESP). A 3-D numerical analysis has been carried out to find the roughness effect on ESP. The performance of pump for steady wall bounded turbulent flows is evaluated at different roughness values and compared with smooth surface considering a non-dimensional roughness factor K. The k- ω SST turbulence model with fine mesh at near wall region captures the rough wall effects accurately. Computational results are validated with experimental results of water (1 cP), at a design speed (3000 RPM). Maximum head is observed for a hydraulically smooth surface (K=0). When roughness factor is increased, the head decreases till critical roughness factor (K=0.1) due to frictional loss. Further increase in roughness factor (K>0.1) increases the head due to near wall turbulence. The performance of ESP is analyzed for turbulent kinetic energy and eddy viscosity at different roughness values. The wall disturbance over the rough surface affects the pressure distribution and velocity field. The roughness effect is predominant for high viscosity oil (43cP) as compared to water. Moreover, the study at off-design conditions showed that Reynolds number influences the overall roughness effect.

  13. A Review of Experiments and Modeling of Gas-Liquid Flow in Electrical Submersible Pumps

    Directory of Open Access Journals (Sweden)

    Jianjun Zhu

    2018-01-01

    Full Text Available As the second most widely used artificial lift method in petroleum production (and first in produced amount, electrical submersible pump (ESP maintains or increases flow rate by converting kinetic energy to hydraulic pressure of hydrocarbon fluids. To facilitate its optimal working conditions, an ESP has to be operated within a narrow application window. Issues like gas involvement, changing production rate and high oil viscosity, greatly impede ESP boosting pressure. Previous experimental studies showed that the presence of gas would cause ESP hydraulic head degradation. The flow behaviors inside ESPs under gassy conditions, such as pressure surging and gas pockets, further deteriorate ESP pressure boosting ability. Therefore, it is important to know what parameters govern the gas-liquid flow structure inside a rotating ESP and how it can be modeled. This paper presents a comprehensive review on the key factors that affect ESP performance under gassy flow conditions. Furthermore, the empirical and mechanistic models for predicting ESP pressure increment are discussed. The computational fluid dynamics (CFD-based modeling approach for studying the multiphase flow in a rotating ESP is explained as well. The closure relationships that are critical to both mechanistic and numerical models are reviewed, which are helpful for further development of more accurate models for predicting ESP gas-liquid flow behaviors.

  14. ESP [electric submersible pump] performance in sand-laden fluids in the Bellshill Lake field

    Energy Technology Data Exchange (ETDEWEB)

    Dowhaniuk, W. (Petro-Canada Resources, Killam, AB (Canada))

    1992-06-01

    Electric submersible pumps (ESPs) used by Petro-Canada in the Bellshill Lake basal quartz pool, were first used as a means of high volume lift in 1976. Traditionally used in areas of the reservoir with limited sand production, ESPs were run in the more permeable and porous areas of the reservoir consisting mainly of unconsolidated sandstones in 1987. Reservoir inflow and sand production was prolific, and ESPs in these wells typically ran for 2-3 days before catastrophic failure occurred, due to the high concentration of abrasives in the produced fluids. As a result of the failures a study was carried out to identify the problems associated with ESPs and abrasives and to determine economic solutions. As a result of the study, the following measures were implemented to improve the service lives of ESPs in the field. All wells that are converted to ESPs are reperforated at 39 shots/m to reduce the pressure drop across the perforations and thus reduce the inflow of sand. New and rebuilt ESPs are assembled without the conventional brass sleeves, instead using Ni-resist parts to avoid hydrogen sulfide attack and degradation. Rubber bearing radially stabilized design counteracts the effect of sand-laden fluid, and drawdown is limited for the first 2-4 weeks of production. Current ESP run-times range up to 2.5 years, and no rubber bearing ESPs have failed due to sand production. 8 refs., 10 figs.

  15. A Hydraulic Motor-Alternator System for Ocean-Submersible Vehicles

    Science.gov (United States)

    Aintablian, Harry O.; Valdez, Thomas I.; Jones, Jack A.

    2012-01-01

    An ocean-submersible vehicle has been developed at JPL that moves back and forth between sea level and a depth of a few hundred meters. A liquid volumetric change at a pressure of 70 bars is created by means of thermal phase change. During vehicle ascent, the phase-change material (PCM) is melted by the circulation of warm water and thus pressure is increased. During vehicle descent, the PCM is cooled resulting in reduced pressure. This pressure change is used to generate electric power by means of a hydraulic pump that drives a permanent magnet (PM) alternator. The output energy of the alternator is stored in a rechargeable battery that powers an on-board computer, instrumentation and other peripherals.The focus of this paper is the performance evaluation of a specific hydraulic motor-alternator system. Experimental and theoretical efficiency data of the hydraulic motor and the alternator are presented. The results are used to evaluate the optimization of the hydraulic motor-alternator system. The integrated submersible vehicle was successfully operated in the Pacific Ocean near Hawaii. A brief overview of the actual test results is presented.

  16. Test Procedure - pumping system for caustic addition project

    Energy Technology Data Exchange (ETDEWEB)

    Leshikar, G.A.

    1994-10-01

    This test procedure provides the requirements for sub-system testing and integrated operational testing of the submersible mixer pump and caustic addition equipment by WHC and Kaiser personnel at the Rotating Equipment Shop run-in pit (Bldg. 272E).

  17. Absorption heat pump system

    Science.gov (United States)

    Grossman, Gershon

    1984-01-01

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  18. Pumping approximately integrable systems

    Science.gov (United States)

    Lange, Florian; Lenarčič, Zala; Rosch, Achim

    2017-06-01

    Weak perturbations can drive an interacting many-particle system far from its initial equilibrium state if one is able to pump into degrees of freedom approximately protected by conservation laws. This concept has for example been used to realize Bose-Einstein condensates of photons, magnons and excitons. Integrable quantum systems, like the one-dimensional Heisenberg model, are characterized by an infinite set of conservation laws. Here, we develop a theory of weakly driven integrable systems and show that pumping can induce large spin or heat currents even in the presence of integrability breaking perturbations, since it activates local and quasi-local approximate conserved quantities. The resulting steady state is qualitatively captured by a truncated generalized Gibbs ensemble with Lagrange parameters that depend on the structure but not on the overall amplitude of perturbations nor the initial state. We suggest to use spin-chain materials driven by terahertz radiation to realize integrability-based spin and heat pumps.

  19. Performance of a pump system for diode-pumped lasers

    Science.gov (United States)

    Stratan, Aurel; Fenic, Constantin G.; Dabu, Razvan V.; Herisanu, Nicolae A.; Luculescu, C.; Sporea, Dan G.; Dumitru, Gabriel; Iordache, Gheorghe

    1998-07-01

    We have developed a laser-diode pump system for continuous-wave end-pumping of Nd:YAG lasers. The pump system includes a pair of 1 W diode-arrays mounted in coaxial enclosures, a driver unit and the pump optics. The array wavelength was temperature tuned to achieve the maximum absorption of the pump radiation in the Nd:YAG crystal. The characteristics of the pump system are presented and the pump-beam profile is investigated.

  20. Absorption heat pump system

    Science.gov (United States)

    Grossman, Gershon; Perez-Blanco, Horacio

    1984-01-01

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  1. Evaluation of station keeping systems for deepwater drilling semi-submersibles

    Science.gov (United States)

    Song, An-Ke; Sun, Li-Ping; Luo, Yong; Wang, Qiang

    2010-09-01

    This paper addresses the need for systematic evaluation of the station keeping systems of deepwater drilling semi-submersibles. Based on the selected drilling semi-submersible configuration, the mooring systems were analyzed and designed for a range of water depths using different mooring line materials. These were steel wire rope, polyester rope and HMPE (high modulus poly ethylene). The mooring analysis was carried out using the advanced fully coupled time domain analysis method in the computer software package HARP. Diffraction analysis was first applied to solve the hydrodynamic properties of the vessel and then the motion equations of the complete dynamic system including the drilling rig, the mooring lines and risers were developed and solved in the time domain. Applying the advanced analysis method, a matrix of mooring systems was developed for operating in water depths of 1 000 m, 1 500 m, and 2 000 m using various mooring materials. The development of mooring systems was conducted in accordance with the commonly adopted mooring design code, API RP 2SK and API RP 2SM. Fresh attempts were then made to comparatively evaluate the mooring system’s characteristics and global performance. Useful results have been obtained in terms of mooring materials, water depths, and key parameters of mooring configurations. The results provide in-depth insight for the design and operation of deepwater mooring systems in the South China Sea environment.

  2. Study Of Calculation Of Degaussing System For Reducing Magnetic Field From Submersible Vehicle

    Directory of Open Access Journals (Sweden)

    Sardono Sarwito

    2017-03-01

    Full Text Available The rapid development of maritime technology in the world to make Indonesia are also increasingly taking the development of maritime technology, such as in a Submersible Vehicle one is degaussing system, this technology should be owned by the vessel so that the vessel can avoid dangerous explosive equipment contained in the sea. Degaussing system is a system that is in use on the metal parts or electronic devices that are at risk of a magnetic field. This system is used to prevent the vessel from dangerous equipment in the sea which can trigger an explosion and the damage that utilize magnetic fields as a metal-detection sensor when the boat was doing dives. To the authors will plan the design degaussing system, and calculating the system in order to reduce the magnetic properties of the Submersible Vehicle which were obtained by the use of Coil Degaussing along 214,5 meters, a diameter of 0,2, with 500.000 coil that will generate a current of 0,0157 Ampere's 0.0787 Tesla generates a magnetic field.

  3. Fuel Pumping System And Method

    Science.gov (United States)

    Shafer, Scott F.; Wang, Lifeng

    2005-12-13

    A fuel pumping system that includes a pump drive is provided. A first pumping element is operatively connected to the pump drive and is operable to generate a first flow of pressurized fuel. A second pumping element is operatively connected to the pump drive and is operable to generate a second flow of pressurized fuel. A first solenoid is operatively connected to the first pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the first flow of pressurized fuel. A second solenoid is operatively connected to the second pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the second flow of pressurized fuel.

  4. Improving pumping system efficiency at coal plants

    Energy Technology Data Exchange (ETDEWEB)

    Livoti, W.C.; McCandless, S.; Poltorak, R. [Baldor Electric Co. (United States)

    2009-03-15

    The industry must employ ultramodern technologies when building or upgrading power plant pumping systems thereby using fuels more efficiently. The article discusses the uses and efficiencies of positive displacement pumps, centrifugal pumps and multiple screw pumps. 1 ref., 4 figs.

  5. Switching model photovoltaic pumping system

    Science.gov (United States)

    Anis, Wagdy R.; Abdul-Sadek Nour, M.

    Photovoltaic (PV) pumping systems are widely used due to their simplicity, high reliability and low cost. A directly-coupled PV pumping system is the most reliable and least-cost PV system. The d.c. motor-pump group is not, however, working at its optimum operating point. A battery buffered PV pumping system introduces a battery between the PV array and the d.c. motor-pump group to ensure that the motor-pump group is operating at its optimum point. The size of the battery storage depends on system economics. If the battery is fully charged while solar radiation is available, the battery will discharge through the load while the PV array is disconnected. Hence, a power loss takes place. To overcome the above mentioned difficulty, a switched mode PV pumping is proposed. When solar radiation is available and the battery is fully charged, the battery is disconnected and the d.c. motor-pump group is directly coupled to the PV array. To avoid excessive operating voltage for the motor, a part of the PV array is switched off to reduce the voltage. As a result, the energy loss is significantly eliminated. Detailed analysis of the proposed system shows that the discharged water increases by about 10% when compared with a conventional battery-buffered system. The system transient performance just after the switching moment shows that the system returns to a steady state in short period. The variations in the system parameters lie within 1% of the rated values.

  6. Numerical Investigation of a Tuned Heave Plate Energy-Harvesting System of a Semi-Submersible Platform

    Directory of Open Access Journals (Sweden)

    Kun Liu

    2016-01-01

    Full Text Available A novel tuned heave plate energy-harvesting system (THPEH is presented for the motion suppressing and energy harvesting of a semi-submersible platform. This THPEH system is designed based on the principle of a tuned mass damper (TMD and is composed of spring supports, a power take-off system (PTO and four movable heave plates. The permanent magnet linear generators (PMLG are used as the PTO system in this design. A semi-submersible platform operating in the South China Sea is selected as the research subject for investigating the effects of the THPEH system on motion reduction and harvesting energy through numerical simulations. The numerical model of the platform and the THPEH system, which was established based on hydrodynamic analysis, is modified and validated by the results of the flume test of a 1:70 scale model. The effects of the parameters, including the size, the frequency ratio and the damping ratio of the THPEH system, are systematically investigated. The results show that this THPEH system, with proper parameters, could significantly reduce the motions of the semi-submersible platform and generate considerable power under different wave conditions.

  7. Superconducting Electric Boost Pump for Nuclear Thermal Propulsion Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A submersible, superconducting electric boost pump sized to meet the needs of future Nuclear Thermal Propulsion systems in the 25,000 lbf thrust range is proposed....

  8. Integrated System Design for a Large Wind Turbine Supported on a Moored Semi-Submersible Platform

    Directory of Open Access Journals (Sweden)

    Jinsong Liu

    2018-01-01

    Full Text Available Over the past few decades, wind energy has emerged as an alternative to conventional power generation that is economical, environmentally friendly and, importantly, renewable. Specifically, offshore wind energy is being considered by a number of countries to harness the stronger and more consistent wind resource compared to that over land. To meet the projected “20% energy from wind by 2030” scenario that was announced in 2006, 54 GW of added wind energy capacity need to come from offshore according to a National Renewable Energy Laboratory (NREL study. In this study, we discuss the development of a semi-submersible floating offshore platform with a catenary mooring system to support a very large 13.2-MW wind turbine with 100-m blades. An iterative design process is applied to baseline models with Froude scaling in order to achieve preliminary static stability. Structural dynamic analyses are performed to investigate the performance of the new model using a finite element method approach for the tower and a boundary integral equation (panel method for the platform. The steady-state response of the system under uniform wind and regular waves is first studied to evaluate the performance of the integrated system. Response amplitude operators (RAOs are computed in the time domain using white-noise wave excitation; this serves to highlight nonlinear, as well as dynamic characteristics of the system. Finally, selected design load cases (DLCs and the stochastic dynamic response of the system are studied to assess the global performance for sea states defined by wind fields with turbulence and long-crested irregular waves.

  9. Heat pumping in nanomechanical systems

    Science.gov (United States)

    Arrachea, Liliana; Chamon, Claudio; Mucciolo, Eduardo; Capaz, Rodrigo

    2011-03-01

    We propose using phonon pumping mechanism to transfer heat from a cold to a hot body. The mechanism is based on inducing a traveling modulation of the acoustic phonon velocity along the medium connecting the two bodies. This phonon pumping can cool nanomechanical systems without the need for active feedback. We have derived an estimate of the lowest achievable temperature. We have also analyzed this mechanism in the framework of simple one-dimensional microscopic models, which can be exactly solved with non-equilibrium Green function techniques. J. S. Guggenheim Memorial Foundation.

  10. Heat pump system

    Science.gov (United States)

    Swenson, Paul F.; Moore, Paul B.

    1977-01-01

    An air heating and cooling system for a building includes an expansion type refrigeration circuit and a vapor power circuit. The refrigeration circuit includes two heat exchangers, one of which is communicated with a source of indoor air from the building and the other of which is communicated with a source of air from outside the building. The vapor power circuit includes two heat exchangers, one of which is disposed in series air flow relationship with the indoor refrigeration circuit heat exchanger and the other of which is disposed in series air flow relationship with the outdoor refrigeration circuit heat exchanger. Fans powered by electricity generated by a vapor power circuit alternator circulate indoor air through the two indoor heat exchangers and circulate outside air through the two outdoor heat exchangers. The system is assembled as a single roof top unit, with a vapor power generator and turbine and compressor thermally insulated from the heat exchangers, and with the indoor heat exchangers thermally insulated from the outdoor heat exchangers.

  11. Heat pump system

    Science.gov (United States)

    Swenson, Paul F.; Moore, Paul B.

    1979-01-01

    An air heating and cooling system for a building includes an expansion-type refrigeration circuit and a heat engine. The refrigeration circuit includes two heat exchangers, one of which is communicated with a source of indoor air from the building and the other of which is communicated with a source of air from outside the building. The heat engine includes a heat rejection circuit having a source of rejected heat and a primary heat exchanger connected to the source of rejected heat. The heat rejection circuit also includes an evaporator in heat exchange relation with the primary heat exchanger, a heat engine indoor heat exchanger, and a heat engine outdoor heat exchanger. The indoor heat exchangers are disposed in series air flow relationship, with the heat engine indoor heat exchanger being disposed downstream from the refrigeration circuit indoor heat exchanger. The outdoor heat exchangers are also disposed in series air flow relationship, with the heat engine outdoor heat exchanger disposed downstream from the refrigeration circuit outdoor heat exchanger. A common fluid is used in both of the indoor heat exchangers and in both of the outdoor heat exchangers. In a first embodiment, the heat engine is a Rankine cycle engine. In a second embodiment, the heat engine is a non-Rankine cycle engine.

  12. Absorption-heat-pump system

    Science.gov (United States)

    Grossman, G.; Perez-Blanco, H.

    1983-06-16

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  13. An economic evaluation comparison of solar water pumping system with engine pumping system for rice cultivation

    Science.gov (United States)

    Treephak, Kasem; Thongpron, Jutturit; Somsak, Dhirasak; Saelao, Jeerawan; Patcharaprakiti, Nopporn

    2015-08-01

    In this paper we propose the design and economic evaluation of the water pumping systems for rice cultivation using solar energy, gasoline fuel and compare both systems. The design of the water and gasoline engine pumping system were evaluated. The gasoline fuel cost used in rice cultivation in an area of 1.6 acres. Under same conditions of water pumping system is replaced by the photovoltaic system which is composed of a solar panel, a converter and an electric motor pump which is compose of a direct current (DC) motor or an alternating current (AC) motor with an inverter. In addition, the battery is installed to increase the efficiency and productivity of rice cultivation. In order to verify, the simulation and economic evaluation of the storage energy battery system with batteries and without batteries are carried out. Finally the cost of four solar pumping systems was evaluated and compared with that of the gasoline pump. The results showed that the solar pumping system can be used to replace the gasoline water pumping system and DC solar pump has a payback less than 10 years. The systems that can payback the fastest is the DC solar pumping system without batteries storage system. The system the can payback the slowest is AC solar pumping system with batteries storage system. However, VAC motor pump of 220 V can be more easily maintained than the motor pump of 24 VDC and batteries back up system can supply a more stable power to the pump system.

  14. Performance of a 10 kilowatt wind-electric water pumping system for irrigating crops

    Energy Technology Data Exchange (ETDEWEB)

    Vick, B.D.; Clark, R.N. [Conservation and Production Research Lab., Bushland, TX (United States); Molla, S. [Texas A& M Univ., College Station, TX (United States)

    1997-12-31

    A 10 kW wind-electric water pumping system was tested for field crop irrigation at pumping depths from 50 to 120 m. The wind turbine for this system used a permanent magnet alternator that powered off-the-shelf submersible motors and pumps without the use of an inverter. Pumping performance was determined at the USDA-Agricultural Research Service (ARS), Wind Energy Laboratory in Bushland, TX for the 10 kW wind turbine using a pressure valve and a pressure tank to simulate different pumping depths. Pumping performance was measured for two 10 kW wind turbines of the same type at farms near the cities of Garden City, TX and Stiles, TX. The pumping performance data collected at these actual wells compared favorably with the data collected at the USDA-ARS, Wind Energy Laboratory. If utility generated electricity was accessible, payback on the wind turbine depended on the cost of utility generated electricity and the transmission line extension cost.

  15. PUMPED LASER SYSTEM USING FEEDBACK TO PUMP MEANS

    DEFF Research Database (Denmark)

    2008-01-01

    A laser system according to the invention comprises pump generating means (xO2, xO3) for generating at least a first and a second, preferably focused, pump beam, and lasing means (xO6, xO7) for emitting radiation by being appropriately pumped. The lasing means (xO6, xO7) is disposed in a first......-switch (xO8; x17, x18) is disposed in the first and the second resonator, so that the first beam and the second beam both pass a Q-switch (xO8; x17, x18). The laser system (x01 ) has an output (x13) generated from said first beam (x21) and said second beam (x22), and at least a part of said output (x13...

  16. Reciprocating Pump Systems for Space Propulsion

    Energy Technology Data Exchange (ETDEWEB)

    Whitehead, J C

    2004-06-10

    Small propellant pumps can reduce rocket hardware mass, while increasing chamber pressure to improve specific impulse. The maneuvering requirements for planetary ascent require an emphasis on mass, while those of orbiting spacecraft indicate that I{sub SP} should be prioritized during pump system development. Experimental efforts include initial testing with prototype lightweight components while raising pump efficiency to improve system I{sub SP}.

  17. Submersion and acute respiratory failure

    Directory of Open Access Journals (Sweden)

    Yu-Jang Su

    2014-01-01

    Conclusions: Submersion patients who are hypothermic on arrival of emergency department (ED are risky to respiratory failure and older, more hypothermic, longer hospital stay in suicidal submersion patients.

  18. Pumps for medium sized solar systems

    DEFF Research Database (Denmark)

    Furbo, Simon

    1996-01-01

    The suitability of the electronically controlled circulation pump type UPE 2000 from Grundfos for large solar heating systems was elucidated.......The suitability of the electronically controlled circulation pump type UPE 2000 from Grundfos for large solar heating systems was elucidated....

  19. The role of capacitance in a wind-electric water pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Ling, Shitao [West Texas A& M Univ., Canyon, TX (United States); Clark, R.N. [Conservation and Production Research Lab., Bushland, TX (United States)

    1997-12-31

    The development of controllers for wind-electric water pumping systems to enable the use of variable voltage, variable frequency electricity to operate standard AC submersible pump motors has provided a more efficient and flexible water pumping system to replace mechanical windmills. A fixed capacitance added in parallel with the induction motor improves the power factor and starting ability of the pump motor at the lower cut-in frequency. The wind-electric water pumping system developed by USDA-Agricultural Research Service, Bushland, TX, operated well at moderate wind speeds (5-12 m/s), but tended to lose synchronization in winds above 12 m/s, especially if they were gusty. Furling generally did not occur until synchronization had been lost and the winds had to subside before synchronization could be reestablished. The frequency needed to reestablish synchronization was much lower (60-65 Hz) than the frequency where synchronization was lost (70-80 Hz). As a result, the load (motor and pump) stayed off an excessive amount of time thus causing less water to be pumped and producing a low system efficiency. The controller described in this paper dynamically connects additional capacitance of the proper amount at the appropriate time to keep the system synchronized (running at 55 to 60 Hz) and pumping water even when the wind speed exceeds 15 m/s. The system efficiency was improved by reducing the system off-line time and an additional benefit was reducing the noise caused by the high speed blade rotation when the load was off line in high winds.

  20. Method and system for small scale pumping

    Energy Technology Data Exchange (ETDEWEB)

    Insepov, Zeke [Darien, IL; Hassanein, Ahmed [Bolingbrook, IL

    2010-01-26

    The present invention relates generally to the field of small scale pumping and, more specifically, to a method and system for very small scale pumping media through microtubes. One preferred embodiment of the invention generally comprises: method for small scale pumping, comprising the following steps: providing one or more media; providing one or more microtubes, the one or more tubes having a first end and a second end, wherein said first end of one or more tubes is in contact with the media; and creating surface waves on the tubes, wherein at least a portion of the media is pumped through the tube.

  1. A Simplified Heat Pump Model for use in Solar Plus Heat Pump System Simulation Studies

    OpenAIRE

    Perers, Bengt; Anderssen, Elsa; Nordman, Roger; Kovacs, Peter

    2012-01-01

    Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the he...

  2. Manned submersible „JAGO“

    Directory of Open Access Journals (Sweden)

    Karen Hissmann

    2017-04-01

    Full Text Available The manned submersible „JAGO“ is a human occupied underwater vehicle (HOV designed for personal exploration and research in all types of aquatic systems and habitats. The seafloor along the continental shelf and slopes within the ocean twilight zone is JAGO’s main target area. The DNV-GL classed 2-person submersible has a maximum operating depth of 400 m. The two occupants, the pilot and one observer, are seated at 1 Atmosphere in a steel pressure hull with two large acrylic windows. The submersible’s small size and lightweight construction (3 T allows worldwide operations from on board a wide variety of vessels as well as transport in a single standard 20-foot container together with all support equipment. Typical applications include personal observation of the sea bed and water column, video and photo documentation, selective non-intrusive sampling, placement of sensors and experiments, underwater inspection, as well as location and recovery of objects

  3. Pumping Optimization Model for Pump and Treat Systems - 15091

    Energy Technology Data Exchange (ETDEWEB)

    Baker, S.; Ivarson, Kristine A.; Karanovic, M.; Miller, Charles W.; Tonkin, M.

    2015-01-15

    Pump and Treat systems are being utilized to remediate contaminated groundwater in the Hanford 100 Areas adjacent to the Columbia River in Eastern Washington. Design of the systems was supported by a three-dimensional (3D) fate and transport model. This model provided sophisticated simulation capabilities but requires many hours to calculate results for each simulation considered. Many simulations are required to optimize system performance, so a two-dimensional (2D) model was created to reduce run time. The 2D model was developed as a equivalent-property version of the 3D model that derives boundary conditions and aquifer properties from the 3D model. It produces predictions that are very close to the 3D model predictions, allowing it to be used for comparative remedy analyses. Any potential system modifications identified by using the 2D version are verified for use by running the 3D model to confirm performance. The 2D model was incorporated into a comprehensive analysis system (the Pumping Optimization Model, POM) to simplify analysis of multiple simulations. It allows rapid turnaround by utilizing a graphical user interface that: 1 allows operators to create hypothetical scenarios for system operation, 2 feeds the input to the 2D fate and transport model, and 3 displays the scenario results to evaluate performance improvement. All of the above is accomplished within the user interface. Complex analyses can be completed within a few hours and multiple simulations can be compared side-by-side. The POM utilizes standard office computing equipment and established groundwater modeling software.

  4. Damages on pumps and systems the handbook for the operation of centrifugal pumps

    CERN Document Server

    Merkle, Thomas

    2014-01-01

    Damage on Pumps and Systems. The Handbook for the Operation of Centrifugal Pumps offers a combination of the theoretical basics and practical experience for the operation of circulation pumps in the engineering industry. Centrifugal pumps and systems are extremely vulnerable to damage from a variety of causes, but the resulting breakdown can be prevented by ensuring that these pumps and systems are operated properly. This book provides a total overview of operating centrifugal pumps, including condition monitoring, preventive maintenance, life cycle costs, energy savings and economic aspects. Extra emphasis is given to the potential damage to these pumps and systems, and what can be done to prevent breakdown. Addresses specific issues about pumping of metal chips, sand, abrasive dust and other solids in fluidsEmphasis on economic and efficiency aspects of predictive maintenance and condition monitoring Uses life cycle costs (LCC) to evaluate and calculate the costs of pumping systems

  5. Wind pump system FC 4000 measurement on a model

    Energy Technology Data Exchange (ETDEWEB)

    Grisko, J.

    1993-02-01

    Small electrical wind pump systems in developing countries, and in general, are described in addition to the wind pump system designated FC 4000. The latter system supports pump heads from 50 to 8 m in a frequency range of 43 - to 17 Hz. The results of measurements taken on the FC 4000 pump system are presented graphically. (AB)

  6. Problems of energy efficiency of pumps and pumping systems

    Science.gov (United States)

    Tverdokhleb, I.; Kostyuk, A.; Sokolov, S.

    2017-08-01

    The total energy consumption of various types of pumps is significant and the energy saving potential in this area is also huge. The transition from consideration of the characteristics of a separate pump to the features of its operation with a drive, taking into account the operation in different modes in conditions of a specific hydraulic network, allows obtaining a much greater potential for reducing energy consumption, significantly increasing the efficiency and reliability of pumping equipment.

  7. Solar-powered turbocompressor heat pump system

    Science.gov (United States)

    Landerman, A.M.; Biancardi, F.R.; Melikian, G.; Meader, M.D.; Kepler, C.E.; Anderson, T.J.; Sitler, J.W.

    1982-08-12

    The turbocompressor comprises a power turbine and a compressor turbine having respective rotors and on a common shaft, rotatably supported by bearings. A first working fluid is supplied by a power loop and is expanded in the turbine. A second working fluid is compressed in the turbine and is circulated in a heat pump loop. A lubricant is mixed with the second working fluid but is excluded from the first working fluid. The bearings are cooled and lubricated by a system which circulates the second working fluid and the intermixed lubricant through the bearings. Such system includes a pump, a thermostatic expansion valve for expanding the working fluid into the space between the bearings, and a return conduit system for withdrawing the expanded working fluid after it passes through the bearings and for returning the working fluid to the evaporator. A shaft seal excludes the lubricant from the power turbine. The power loop includes a float operable by liquid working fluid in the condenser for controlling a recirculation valve so as to maintain a minimum liquid level in the condenser, while causing a feed pump to pump most of the working fluid into the vapor generator. The heat pump compressor loop includes a float in the condenser for operating and expansion valve to maintain a minimum liquid working fluid level in the condenser while causing most of the working fluid to be expanded into the evaporator.

  8. Root cause analysis of pump valve failures of three membrane pump systems

    NARCIS (Netherlands)

    Buijs, L.J.; Eijk, A.; Hooft, L. van

    2014-01-01

    This paper will present the root cause analysis and the solution of fatigue failures of the pump valves of three membrane pump systems installed on a chemical plant of Momentive in Pernis, the Netherlands. The membrane pumps were installed approximately 30 years ago. Each system has encountered

  9. A simplified heat pump model for use in solar plus heat pump system simulation studies

    DEFF Research Database (Denmark)

    Perers, Bengt; Andersen, Elsa; Nordman, Roger

    2012-01-01

    Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here...... is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the heat pump. By plotting heat pump test data in different ways including power input and output form and not only...... as COP, a simplified relation could be seen. By using the same methodology as in the EN 12975 QDT part in the collector test standard it could be shown that a very simple model could describe the heat pump test data very accurately, by identifying 4 parameters in the correlation equation found....

  10. Heat pump having improved defrost system

    Science.gov (United States)

    Chen, Fang C.; Mei, Viung C.; Murphy, Richard W.

    1998-01-01

    A heat pump system includes, in an operable relationship for transferring heat between an exterior atmosphere and an interior atmosphere via a fluid refrigerant: a compressor; an interior heat exchanger; an exterior heat exchanger; an accumulator; and means for heating the accumulator in order to defrost the exterior heat exchanger.

  11. Heat Pumps in CHP Systems

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt

    representation allows infeasible production. Using MIP or NLP optimisation, the number of operation hours and the total production of heat from HPs are significantly increased, as the HPs may be used to shave the load patterns of CHP units in significantly constrained energy systems. A MIP energy system model...

  12. Solar power pumping system for domestic appliences

    OpenAIRE

    Lukhwareni, T.; Gouws, R.; Dobzhanskyi, O.

    2014-01-01

    With the world encountering huge pollution problems, use of renewable energy is being encouraged in place of fossils fuels for electricity generation. On such renewable energies is solar power. Solar powered systems are able to generate electricity using photovoltaic (PV) panels, or thermal collectors directly from sunlight. Pool pump electricity consumption has also risen in South Africa. This paper presents the results of the design, and construction of a PV solar system to effect water pum...

  13. Design of Pumps for Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Klit, Peder; Olsen, Stefan; Bech, Thomas Nørgaard

    1999-01-01

    This paper considers the development of two pumps for water hydraulic applications. The pumps are based on two different working principles: The Vane-type pump and the Gear-type pump. Emphasis is put on the considerations that should be made to account for water as the hydraulic fluid.......KEYWORDS: water, pump, design, vane, gear....

  14. Submersible Generator for Marine Hydrokinetics

    Energy Technology Data Exchange (ETDEWEB)

    Cinq-Mars, Robert S; Burke, Timothy; Irish, James; Gustafson, Brian; Kirtley, James; Alawa, Aiman

    2011-09-01

    A submersible generator was designed as a distinct and critical subassembly of marine hydrokinetics systems, specifically tidal and stream energy conversion. The generator is designed to work with both vertical and horizontal axis turbines. The final product is a high-pole-count, radial-flux, permanent magnet, rim mounted generator, initially rated at twenty kilowatts in a two-meter-per-second flow, and designed to leverage established and simple manufacturing processes. The generator was designed to work with a 3 meter by 7 meter Gorlov Helical Turbine or a marine hydrokinetic version of the FloDesign wind turbine. The team consisted of experienced motor/generator design engineers with cooperation from major US component suppliers (magnetics, coil winding and electrical steel laminations). Support for this effort was provided by Lucid Energy Technologies and FloDesign, Inc. The following tasks were completed: Identified the conditions and requirements for MHK generators. Defined a methodology for sizing and rating MHK systems. Selected an MHK generator topology and form factor. Completed electromechanical design of submersible generator capable of coupling to multiple turbine styles. Investigated MHK generator manufacturing requirements. Reviewed cost implications and financial viability. Completed final reporting and deliverables

  15. Energy Efficient Pump Control for an Offshore Oil Processing System

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Soleiman, Kian; Løhndorf, Bo

    2012-01-01

    The energy efficient control of a pump system for an offshore oil processing system is investigated. The seawater is lifted up by a pump system which consists of three identical centrifugal pumps in parallel, and the lifted seawater is used to cool down the crude oil flowing out of a threephase...... separator on one of the Danish north-sea platform. A hierarchical pump-speed control strategy is developed for the considered system by minimizing the pump power consumption subject to keeping a satisfactory system performance. The proposed control strategy consists of online estimation of some system...... operating parameters, optimization of pump configurations, and a real-time feedback control. Comparing with the current control strategy at the considered system, where the pump system is on/off controlled, and the seawater flows are controlled by a number of control valves, the proposed control strategy...

  16. The characterization of axenic culture systems suitable for plant propagation and experimental studies of the submersed aquatic angiosperm Potamogeton pectinatus (Sago pondweed)

    Science.gov (United States)

    Ailstock, M.S.; Fleming, W.J.; Cooke, T.J.

    1991-01-01

    Clonal lines of the submersed aquatic angiosperm Potamogeton pectinatus were grown in three culture systems. The first, which used sucrose as a carbon source in a liquid medium, supported vigorous vegetative growth and can be used to propagate large numbers of plants in axenic conditions. In this culture system, plants were responsive to increasing photosynthetically active radiation (PAR) photon flux density (PFD) and were photosynthetically competent. However, their growth was heterotrophic and root development was poor. When these plants were transferred to a second nonaxenic culture system, which used 16-l buckets containing artificial sediments and tap water, growth was autotrophic and plants were morphologically identical to field-harvested P. pectinatus. The last culture system which consisted of a sand substrate and inorganic nutrient bathing solution aerated with 135 ml min-1 ambient air enhanced to 3.0% CO2 was axenic and supported autotrophic growth by plants that were also morphologically normal.

  17. Contamination of successive samples in portable pumping systems

    Science.gov (United States)

    Robert B. Thomas; Rand E. Eads

    1983-01-01

    Automatic discrete sample pumping systems used to monitor water quality should deliver to storage all materials pumped in a given cycle. If they do not, successive samples will be contaminated, a severe problem with highly variable suspended sediment concentrations in small streams. The cross-contamination characteristics of two small commonly used portable pumping...

  18. Study on operation conditions and an operation system of a nuclear powered submersible research vessel, 'report of working group on application of a very small nuclear reactor to an ocean research'

    Energy Technology Data Exchange (ETDEWEB)

    Ura, Tamaki [Tokyo Univ., Tokyo (Japan); Takamasa, Tomoji [Tokyo Univ. of Mercantile Marine, Tokyo (Japan); Nishimura, Hajime [Japan Marine Science and Technology Center, Yokosuka, Kanagawa (JP)] [and others

    2001-07-01

    JAERI has studied on design of a nuclear powered submersible research vessel, which will navigate under sea mainly in the Arctic Ocean, as a part of the design activity of advanced marine reactors. This report describes operation conditions and an operating system of the vessel, which were discussed by the specialists of hull design, sound positioning, ship motions and oceanography, etc. The design conditions on ship motions for submersible vessels were surveyed considering regulations in our country, and ship motions were evaluated in the cases of underwater and surface navigations taking account of observation activities in the Arctic Ocean. The effect of ship motions on the compact nuclear reactor SCR was assessed. A submarine transponder system and an on-ice communication buoy system were examined as a positioning and communication system, supposing the activity under ice. The interval between transponders or communication buoys was recommended as 130 km. Procedures to secure safety of nuclear powered submersible research vessel were discussed according to accidents on the hull or the nuclear reactor. These results were reflected to the concept of the nuclear powered submersible research vessel, and subjects to be settled in the next step were clarified. (author)

  19. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  20. Induction Motors Most Efficient Operation Points in Pumped Storage Systems

    DEFF Research Database (Denmark)

    Busca-Forcos, Andreea; Marinescu, Corneliu; Busca, Cristian

    2015-01-01

    efficiency is desired especially when operating with renewable energy systems, which present low energy conversion factor (up to 50% - performance coefficient for wind turbines, and efficiency up to 40% for photovoltaic systems). In this paper the most efficient operation points of the induction motors...... in pumped storage systems are established. The variable speed operation of the pumped storage systems and motor loading conditions for pump applications have been the key factors for achieving the purpose of the paper....

  1. Mean Line Pump Flow Model in Rocket Engine System Simulation

    Science.gov (United States)

    Veres, Joseph P.; Lavelle, Thomas M.

    2000-01-01

    A mean line pump flow modeling method has been developed to provide a fast capability for modeling turbopumps of rocket engines. Based on this method, a mean line pump flow code PUMPA has been written that can predict the performance of pumps at off-design operating conditions, given the loss of the diffusion system at the design point. The pump code can model axial flow inducers, mixed-flow and centrifugal pumps. The code can model multistage pumps in series. The code features rapid input setup and computer run time, and is an effective analysis and conceptual design tool. The map generation capability of the code provides the map information needed for interfacing with a rocket engine system modeling code. The off-design and multistage modeling capabilities of the code permit parametric design space exploration of candidate pump configurations and provide pump performance data for engine system evaluation. The PUMPA code has been integrated with the Numerical Propulsion System Simulation (NPSS) code and an expander rocket engine system has been simulated. The mean line pump flow code runs as an integral part of the NPSS rocket engine system simulation and provides key pump performance information directly to the system model at all operating conditions.

  2. Jet pump-drive system for heat removal

    Science.gov (United States)

    French, James R. (Inventor)

    1987-01-01

    The invention does away with the necessity of moving parts such as a check valve in a nuclear reactor cooling system. Instead, a jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A main flow exists for a reactor coolant. A point of withdrawal is provided for a secondary flow. A TEMP, responsive to the heat from said coolant in the secondary flow path, automatically pumps said withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature where the heat is no longer a problem. At this lower temperature, the TEMP/jet pump combination ceases its circulation boosting operation. When the nuclear reactor is restarted and the coolant again exceeds the lower temperature setting, the TEMP/jet pump automatically resumes operation. The TEMP/jet pump combination is thus automatic, self-regulating and provides an emergency pumping system free of moving parts.

  3. Powertrain System HANT: Hydraulic Pump/Motor

    Energy Technology Data Exchange (ETDEWEB)

    1993-06-01

    The development of the new Hydraulic Pump/Motor is the main part of the Powertrain-System HANT. Several Engineering Models of the same design have been tested to prove that the new concept is effective. The important ranges: Maximum pressure and rpm and low power (low pressure, rpm, swashplate angle) were tested successfully. The efficiencies in all areas have already shown the same or better data then those of the best products on the market. The tests have been conducted in Switzerland (maximum power) in 1987 and at the UWM-Madison, Wisconsin (low power efficiency) in 1988. Based on these data and several new useful design features the Engineering Model has been updated. In addition, the reduction of unnecessary safety factor, new materials and mass-production like manufacturing methods, has lead to an significantly improved Prototype Design. The updated version and its expected improved technical data are presented in this report.

  4. Performance of solar photovoltaic array fed water pumping system ...

    African Journals Online (AJOL)

    This paper discusses the design and performance analysis of a solar photovoltaic (SPV) array fed water pumping system utilizing a special class of highly rugged machine with simple drive system called switched reluctance motor (SRM) drive. The proposed method of water pumping system also provides the cost effective ...

  5. Expert system for online surveillance of nuclear reactor coolant pumps

    Energy Technology Data Exchange (ETDEWEB)

    Gross, K.C.; Singer, R.M.; Humenik, K.E.

    1992-12-31

    This report describes an expert system for online surveillance of nuclear reactor coolant pumps. This system provides a means for early detection of pump or sensor degradation. Degradation is determined through the use of a statistical analysis technique, sequential probability ratio test, applied to information from several sensors which are responsive to differing physical parameters. The results of sequential testing of the data provide the operator with an early warning of possible sensor or pump failure.

  6. Origin of Possible Contamination Introduced by a Turbomolecular Pumping System

    CERN Document Server

    Bojon, J P; Weiss, K P

    1999-01-01

    Turbomolecular pumping groups are widely used in accelerators for the pre-evacuation and during the bake-out of the vacuum system. A major requirement for these groups, apart from pumping speed considerations, is the cleanliness of the vacuum produced. In an attempt to clarify this question, a bakeable low-pressure vacuum system has been constructed to allow the direct comparison of the contamination introduced by a turbomolecular pump and by an ideally clean cryopump. This contamination has been checked by the quantitative analysis of the residual gas as well as of the gases desorbed from surfaces under electron bombardment. Contamination by the rotary pump oil is only apparent below 40% of the turbomolecular pump nominal rotation speed. When the pump is stopped, the system is contaminated by heavy hydrocarbons which can be eliminated by a 300°C vacuum bake out.

  7. Submersible Spectrofluorometer for Real-Time Sensing of Water Quality.

    Science.gov (United States)

    Puiu, Adriana; Fiorani, Luca; Menicucci, Ivano; Pistilli, Marco; Lai, Antonia

    2015-06-18

    In this work, we present a newly developed submersible spectrofluorometer (patent pending) applied to real-time sensing of water quality, suitable for monitoring some important indicators of the ecological status of natural waters such as chlorophyll-a, oil and protein-like material. For the optomechanical realization of the apparatus, a novel conceptual design has been adopted in order to avoid filters and pumps while maintaining a high signal-to-noise ratio. The elimination of filters and pumps has the advantage of greater system simplicity and especially of avoiding the risk of sample degradation. The use of light-emitting diodes as an excitation source instead of Xe lamps or laser diodes helped save on size, weight, power consumption and costs. For sensor calibration we performed measurements on water samples with added chlorophyll prepared in the laboratory. The sensor functionality was tested during field campaigns conducted at Albano Lake in Latium Region of Italy as well as in the Herzliya Harbor, a few kilometers North East of Tel Aviv in Israel. The obtained results are reported in the paper. The sensitivity achieved for chlorophyll-a detection was found to be at least 0.2 µg/L.

  8. Coefficient of Performance Stabilisation in Ground Source Heat Pump Systems

    Directory of Open Access Journals (Sweden)

    Jerzy Wołoszyn

    2017-12-01

    Full Text Available The number of installations with ground source heat pumps is steadily increasing. As they involve high investment costs, they require deliberate action and analysis. Research on the influence of design, materials and operating parameters on their coefficient of performance becomes of great importance. In this article the authors propose a new ground source heat pump system with horizontal ground heat exchanger and subsurface irrigation system. In order to examine the possibility of applying the system, the influence of soil moisture content on the heat pump coefficient of performance was investigated in this research. Conducting research on the real object is extremely expensive, so it was decided to conduct simulation studies using the finite element method. The presented results of research confirm that the soil moisture content has the greatest impact on the heat pump system coefficient of performance. The developed ground source heat pump system with subsurface irrigation system allow to reduce the length of ground heat exchanger loop.

  9. Vacuum Pump System Optimization Saves Energy at a Dairy Farm

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-08-01

    In 1998, S&S Dairy optimized the vacuum pumping system at their dairy farm in Modesto, California. In an effort to reduce energy costs, S&S Dairy evaluated their vacuum pumping system to determine if efficiency gains and energy savings were possible.

  10. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [Environ Holdings Inc., Princeton, NJ (United States); Yavuzturk, Cy [Univ. of Hartford, West Hartford, CT (United States); Pinder, George [Univ. of Vermont, Burlington, VT (United States)

    2015-04-01

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  11. Residential heat pumps in the future Danish energy system

    DEFF Research Database (Denmark)

    Petrovic, Stefan; Karlsson, Kenneth Bernard

    2016-01-01

    Denmark is striving towards 100% renewable energy system in 2050. Residential heat pumps are expected to be a part of that system.We propose two novel approaches to improve the representation of residential heat pumps: Coefficients of performance (COPs) are modelled as dependent on air and ground...... temperature while installation of ground-source heat pumps is constrained by available ground area. In this study, TIMES-DK model is utilised to test the effects of improved modelling of residential heat pumps on the Danish energy system until 2050.The analysis of the Danish energy system was done...... for politically agreed targets which include: at least 50% of electricity consumption from wind power starting from 2020, fossil fuel free heat and power sector from 2035 and 100% renewable energy system starting from 2050. Residential heat pumps supply around 25% of total residential heating demand after 2035...

  12. Design and analysis of hydraulic ram water pumping system

    Science.gov (United States)

    Hussin, N. S. M.; Gamil, S. A.; Amin, N. A. M.; Safar, M. J. A.; Majid, M. S. A.; Kazim, M. N. F. M.; Nasir, N. F. M.

    2017-10-01

    The current pumping system (DC water pump) for agriculture is powered by household electricity, therefore, the cost of electricity will be increased due to the higher electricity consumption. In addition, the water needs to be supplied at different height of trees and different places that are far from the water source. The existing DC water pump can pump the water to 1.5 m height but it cost money for electrical source. The hydraulic ram is a mechanical water pump that suitable used for agriculture purpose. It can be a good substitute for DC water pump in agriculture use. The hydraulic ram water pumping system has ability to pump water using gravitational energy or the kinetic energy through flowing source of water. This project aims to analyze and develop the water ram pump in order to meet the desired delivery head up to 3 meter height with less operation cost. The hydraulic ram is designed using CATIA software. Simulation work has been done using ANSYS CFX software to validate the working concept. There are three design were tested in the experiment study. The best design reached target head of 3 m with 15% efficiency and flow rate of 11.82l/min. The results from this study show that the less diameter of pressure chamber and higher supply head will create higher pressure.

  13. District Heating System Using Heat Pump Installations and CHP

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2015-12-01

    Full Text Available The article describes the district heating system, in which part of the heat of return water thermal power is used to supply heat to the district heating puThe article describes the district heating system, in which part of the heat of return water thermal power is used to supply heat to the district heating pumps, evaporators heating and hot water. Heat pumps use carbon dioxide as refrigerant. During the transitional period of the year, and the summer heat pump for preparing hot-water supply system uses the heat of the surrounding air. The heat of the ambient air is used in the intermediate heat exchanger between the first and second stages of the heat pump to cool the gas after the first stage of the compressor of the heat pump.

  14. Elements for Effective Management of Operating Pump and Treat Systems

    Science.gov (United States)

    This fact sheet summarizes key aspects of effective management for operating pump and treat (P&T) systems based on lessons learned from conducting optimization evaluations at 20 Superfund-financed P&T systems.

  15. Performance of solar photovoltaic array fed water pumping system ...

    African Journals Online (AJOL)

    DR OKE

    technologies make solar power a quite attractive solution for standalone power generation and applications like water pumping. SPV array fed water pumping system is fitted with manual or with auto-trackers for synchronizing with the shifting direction of the sun. In this way, solar panel captures sun rays continuously and ...

  16. Optimum design of a photovoltaic powered pumping system

    Science.gov (United States)

    Anis, Wagdy R.; Nour, M. A.

    Photovoltaic (PV)-powered pumping systems are relatively simple and reliable. Hence, they are applied worldwide. Two conventional techniques are currently in use: the first is the 'directly-coupled' system where a PV array is directly coupled to a d.c. motor-pump group; the second is the 'battery-buffered' system where a battery is connected across the array to feed the d.c. motor that drives the pump. Recently, a third system has been proposed, namely, the 'switched-mode' PV-powered pumping system. This system couples the pump to the PV array directly when the storage battery is fully charged. The objective is the maximum utilization of available solar radiation to minimize the cost per pumped cubic meter from a given water depth. For a given location, four main parameters affect the design of this system: (i) d.c. motor-pump group parameters; (ii) PV array size; (iii) battery storage size, and (iv) water storage tank size. It is found that some of the factors are more effective in reducing the cost than others. The PV array size is the predominant factor, while the battery storage and water-tank sizes have relatively less effect. A detailed economic analysis is given.

  17. Engineering approach for cost effective operation of industrial pump systems

    Science.gov (United States)

    Krickis, O.; Oleksijs, R.

    2017-10-01

    Power plants operators are persuaded to operate the main equipment such as centrifugal pumps in economically effective way. The operation of pump sets of district heating network at power plants should be done according to prescriptions of the original equipment manufacturer with further implementation of these requirements to distributed control system of the plant. In order to operate industrial pump sets with a small number of malfunctions is necessary to control the duty point of pump sets in H-Q coordinates, which could be complex task in some installations. Alternatively, pump operation control could be organized in H-n (head vs rpm) coordinates, utilizing pressure transmitters in pressure pipeline and value of rpm from variable speed driver. Safe operation range of the pump has to be limited with system parabolas, which prevents the duty point location outside of the predefined operation area. The particular study demonstrates the engineering approach for pump’s safe operation control development in MATLAB/Simulink environment, which allows to simulate the operation of the pump at different capacities in hydraulic system with variable characteristic and to predefine the conditions for efficient simultaneous pump operation in parallel connection.

  18. Optimization of a pump-pipe system by dynamic programming

    DEFF Research Database (Denmark)

    Vidal, Rene Victor Valqui; Ferreira, Jose S.

    1984-01-01

    In this paper the problem of minimizing the total cost of a pump-pipe system in series is considered. The route of the pipeline and the number of pumping stations are known. The optimization will then consist in determining the control variables, diameter and thickness of the pipe and the size of...... of the pumps. A general mathematical model is formulated and Dynamic Programming is used to find an optimal solution.......In this paper the problem of minimizing the total cost of a pump-pipe system in series is considered. The route of the pipeline and the number of pumping stations are known. The optimization will then consist in determining the control variables, diameter and thickness of the pipe and the size...

  19. Analysis of the reliability of the centrifugal pumping system on the Northeast pole platforms in the Campos basin; Analise de confiabilidade do sistema de bombeio centrifugo das plataformas do polo nordeste da bacia de Campos

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Luiz; Bardy, Mariana [Principia Engenharia de Informatica, Salvador, BA (Brazil); Simoes Filho, Salvador [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES). Div. de Engenharia Basica Industrial; Neves, Edinei [PETROBRAS, Campos, RJ (Brazil). Exploracao e Producao

    1999-12-01

    The results of the statistical analysis of useful life data for the Submersible Centrifugal Pumping (BCS) sets installed in the wells in the Northeast Pole of the Campos Basin are given in this work. The objective is to analyze the data compiled with a view to determine the failure rate distributions for the various system components. These are important for the reliability analysis of the BCS systems and to predict the expected number of equipment acquisitions over a yearly period. In addition, suggestions are made aimed at improving the operational reliability of the systems analyzed. (author)

  20. In situ particle characterization and evidence of ubiquitous particle orientation in the ocean using a submersible holographic imaging system (Conference Presentation)

    Science.gov (United States)

    Nayak, Aditya R.; McFarland, Malcolm N.; Stockley, Nicole D.; Twardowski, Michael S.; Sullivan, James M.

    2017-05-01

    Field experiments with the goal of characterizing aquatic particle properties, including size distributions and orientations in their natural environment, were conducted using a submersible holographic imaging system (HOLOCAM). Digital holography is a non-intrusive technique that allows particle fields to be mapped within a 3-D sampling volume at high resolution. The HOLOCAM was deployed at East Sound, a fjord in the US Pacific Northwest, and Lake Erie over three separate deployments from 2013 to 2015. A database of more than a million particles in the 100-10000 µm size range of varying shape and orientation was created after processing holograms. Furthermore, simultaneous, co-located acoustic Doppler velocimeter measurements of small-scale shear and turbulence structure were used to study the effects of the ambient flow field on particle orientation. Several interesting features presented themselves, with a Microcystis bloom dominating the surface layer of Lake Erie, while `thin layers' of high particle concentrations dominated by colonial diatoms were seen in East Sound. Particle size distribution (PSD) slopes in the 50-250 µm size range were 1.7-1.9, while for particles optics as random particle orientation is inherently assumed in theory and models. Preferential alignment can increase/decrease optical properties such as backscattering and attenuation relative to random distributions.

  1. A Review of the Security of Insulin Pump Infusion Systems

    Energy Technology Data Exchange (ETDEWEB)

    Klonoff, David C. [Mills-Peninsula Health Services; Paul, Nathanael R [ORNL; Kohno, Tadayoshi [University of Washington, Seattle

    2011-01-01

    Insulin therapy has enabled diabetic patients to maintain blood glucose control to lead healthier lives. Today, rather than manually injecting insulin using syringes, a patient can use a device, such as an insulin pump, to programmatically deliver insulin. This allows for more granular insulin delivery while attaining blood glucose control. The insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this paper we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components including the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but we also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues both for now and in the future.

  2. A review of the security of insulin pump infusion systems.

    Science.gov (United States)

    Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C

    2011-11-01

    Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. © 2011 Diabetes Technology Society.

  3. Research on networked manufacturing system for reciprocating pump industry

    Science.gov (United States)

    Wu, Yangdong; Qi, Guoning; Xie, Qingsheng; Lu, Yujun

    2005-12-01

    Networked manufacturing is a trend of reciprocating pump industry. According to the enterprises' requirement, the architecture of networked manufacturing system for reciprocating pump industry was proposed, which composed of infrastructure layer, system management layer, application service layer and user layer. Its main functions included product data management, ASP service, business management, and customer relationship management, its physics framework was a multi-tier internet-based model; the concept of ASP service integration was put forward and its process model was also established. As a result, a networked manufacturing system aimed at the characteristics of reciprocating pump industry was built. By implementing this system, reciprocating pump industry can obtain a new way to fully utilize their own resources and enhance the capabilities to respond to the global market quickly.

  4. EFFECT OF THE CRITICAL IRRADIANCE ON PHOTOVOLTAIC WATER PUMP DISCHARGE UNDER EGYPTIAN CONDITIONS

    Directory of Open Access Journals (Sweden)

    Mamdouh Abbas HELMY

    2015-04-01

    Full Text Available The present investigation aimed to study the effect of critical irradiance due to changing tilt angle of PV panel and tracking sun on submersible pump discharge. The authors used solar tracker and suitable tilt angle for the panel to increase the time interval during which the water pump operates. For the same irradiance collected by the PV, all systems pump the same amount of water, although they occur at different periods of the day. The pump itself 'does not know whether the electric power comes from any processes, as long as it has the same intensity.

  5. Riemannian submersions and related topics

    CERN Document Server

    Falcitelli, Maria; Pastore, Anna Maria

    2004-01-01

    This book provides the first-ever systematic introduction to thetheory of Riemannian submersions, which was initiated by BarrettO''Neill and Alfred Gray less than four decades ago. The authorsfocus their attention on classification theorems when the total spaceand the fibres have nice geometric properties.

  6. Investigation of pump and pump switch failures in rainwater harvesting systems

    Science.gov (United States)

    Moglia, Magnus; Gan, Kein; Delbridge, Nathan; Sharma, Ashok K.; Tjandraatmadja, Grace

    2016-07-01

    Rainwater harvesting is an important technology in cities that can contribute to a number of functions, such as sustainable water management in the face of demand growth and drought as well as the detention of rainwater to increase flood protection and reduce damage to waterways. The objective of this article is to investigate the integrity of residential rainwater harvesting systems, drawing on the results of the field inspection of 417 rainwater systems across Melbourne that was combined with a survey of householders' situation, maintenance behaviour and attitudes. Specifically, the study moves beyond the assumption that rainwater systems are always operational and functional and draws on the collected data to explore the various reasons and rates of failure associated with pumps and pump switches, leaving for later further exploration of the failure in other components such as the collection area, gutters, tank, and overflows. To the best of the authors' knowledge, there is no data like this in academic literature or in the water sector. Straightforward Bayesian Network models were constructed in order to analyse the factors contributing to various types of failures, including system age, type of use, the reason for installation, installer, and maintenance behaviour. Results show that a number of issues commonly exist, such as failure of pumps (5% of systems), automatic pump switches that mediate between the tank and reticulated water (9% of systems), and systems with inadequate setups (i.e. no pump) limiting their use. In conclusion, there appears to be a lack of enforcement or quality controls in both installation practices by sometimes unskilled contractors and lack of ongoing maintenance checks. Mechanisms for quality control and asset management are required, but difficult to promote or enforce. Further work is needed into how privately owned assets that have public benefits could be better managed.

  7. Calibration Transfer Between a Bench Scanning and a Submersible Diode Array Spectrophotometer for In Situ Wastewater Quality Monitoring in Sewer Systems.

    Science.gov (United States)

    Brito, Rita S; Pinheiro, Helena M; Ferreira, Filipa; Matos, José S; Pinheiro, Alexandre; Lourenço, Nídia D

    2016-03-01

    Online monitoring programs based on spectroscopy have a high application potential for the detection of hazardous wastewater discharges in sewer systems. Wastewater hydraulics poses a challenge for in situ spectroscopy, especially when the system includes storm water connections leading to rapid changes in water depth, velocity, and in the water quality matrix. Thus, there is a need to optimize and fix the location of in situ instruments, limiting their availability for calibration. In this context, the development of calibration models on bench spectrophotometers to estimate wastewater quality parameters from spectra acquired with in situ instruments could be very useful. However, spectra contain information not only from the samples, but also from the spectrophotometer generally invalidating this approach. The use of calibration transfer methods is a promising solution to this problem. In this study, calibration models were developed using interval partial least squares (iPLS), for the estimation of total suspended solids (TSS) and chemical oxygen demand (COD) in sewage from Ultraviolet-visible spectra acquired in a bench scanning spectrophotometer. The feasibility of calibration transfer to a submersible, diode array equipment, to be subsequently operated in situ, was assessed using three procedures: slope and bias correction (SBC); single wavelength standardization (SWS) on mean spectra; and local centering (LC). The results showed that SBC was the most adequate for the available data, adding insignificant error to the base model estimates. Single wavelength standardization was a close second best, potentially more robust, and independent of the base iPLS model. Local centering was shown to be inadequate for the samples and instruments used. © The Author(s) 2016.

  8. Heat pumps in combined heat and power systems

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Wiebke Brix; Elmegaard, Brian

    2014-01-01

    Heat pumps have previously been proposed as a way to integrate higher amounts of renewable energy in DH (district heating) networks by integrating, e.g., wind power. The paper identifies and compares five generic configurations of heat pumps in DH systems. The operational performance...... of the considered cases. When considering a case where the heat pump is located at a CHP (combined heat and power) plant, a configuration that increases the DH return temperature proposes the lowest operation cost, as low as 12 EUR MWh-1 for a 90 °C e 40 °C DH network. Considering the volumetric heating capacity......, a third configuration is superior in all cases. Finally, the three most promising heat pump configurations are integrated in a modified PQ-diagram of the CHP plant. Each show individual advantages, and for two, also disadvantages in order to achieve flexible operation....

  9. Heat pump system with selective space cooling

    Science.gov (United States)

    Pendergrass, J.C.

    1997-05-13

    A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve. 4 figs.

  10. Heat pump system with selective space cooling

    Science.gov (United States)

    Pendergrass, Joseph C.

    1997-01-01

    A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve.

  11. Design manual. [High temperature heat pump for heat recovery system

    Energy Technology Data Exchange (ETDEWEB)

    Burch, T.E.; Chancellor, P.D.; Dyer, D.F.; Maples, G.

    1980-01-01

    The design and performance of a waste heat recovery system which utilizes a high temperature heat pump and which is intended for use in those industries incorporating indirect drying processes are described. It is estimated that use of this heat recovery system in the paper, pulp, and textile industries in the US could save 3.9 x 10/sup 14/ Btu/yr. Information is included on over all and component design for the heat pump system, comparison of prime movers for powering the compressor, control equipment, and system economics. (LCL)

  12. Assessment of the dye removal capability of submersed aquatic plants in a laboratory-scale wetland system using anova

    Directory of Open Access Journals (Sweden)

    O. Keskinkan

    2007-06-01

    Full Text Available The textile dye (Basic Blue 41(BB41 removal capability of a laboratory-scale wetland system was presented in this study. Twenty glass aquaria were used to establish the wetland. Myriophyllum spicatum and Ceratophyllum demersum were planted in the aquaria and acclimated. After establishing flow conditions, the aquaria were fed with synthetic wastewaters containing BB41. The concentration of the dye was adjusted to 11.0 mg/L in the synthetic wastewater. Hydraulic retention times (HRTs ranged between 3 and 18 days. Effective HRTs were 9 and 18 days. The highest dye removal rates were 94.8 and 94.1% for M. spicatum and C. demersum aquaria respectively. The statistical ANOVA method was used to assess the dye removal capability of the wetland system. In all cases the ANOVA method revealed that plants in the wetland system and HRT were important factors and the wetland system was able to remove the dye from influent wastewater.

  13. Heat-pump-centered integrated community energy systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-11-01

    A Heat Pump Centered-Integrated Community Energy System (HP-ICES) concept was explored and developed that is based on use of privately owned ice-making heat pumps in each building or complex within a community. These heat pumps will provide all of the space heating, space cooling and domestic hot water needs. All of the community input energy required is provided by electrical power, thereby eliminating a community's dependence on gas or oil supplies. The heat pumps will operate in both air and water source modes, deriving performance advantages of both. The possible forms of an HP-ICES system, the technical and economic limitations, environmental impacts and other factors are discussed from a general viewpoint. The concept is applied to a specific planned community and its performance and economic features are examined in detail. It is concluded that the HP-ICES concept is technically viable, but that its economic desirability as compared with conventional heat pump systems is hampered by much higher initial costs, and that the economic feasibility of HP-ICES systems will depend on future fuel source costs and supply and on electric power rates. (LCL)

  14. Entropy, pricing and macroeconomics of pumped-storage systems

    Science.gov (United States)

    Karakatsanis, Georgios; Mamassis, Nikos; Koutsoyiannis, Demetris; Efstratiadis, Andreas

    2014-05-01

    We propose a pricing scheme for the enhancement of macroeconomic performance of pumped-storage systems, based on the statistical properties of both geophysical and economic variables. The main argument consists in the need of a context of economic values concerning the hub energy resource; defined as the resource that comprises the reference energy currency for all involved renewable energy sources (RES) and discounts all related uncertainty. In the case of pumped-storage systems the hub resource is the reservoir's water, as a benchmark for all connected intermittent RES. The uncertainty of all involved natural and economic processes is statistically quantifiable by entropy. It is the relation between the entropies of all involved RES that shapes the macroeconomic state of the integrated pumped-storage system. Consequently, there must be consideration on the entropy of wind, solar and precipitation patterns, as well as on the entropy of economic processes -such as demand preferences on either current energy use or storage for future availability. For pumped-storage macroeconomics, a price on the reservoir's capacity scarcity should also be imposed in order to shape a pricing field with upper and lower limits for the long-term stability of the pricing range and positive net energy benefits, which is the primary issue of the generalized deployment of pumped-storage technology. Keywords: Entropy, uncertainty, pricing, hub energy resource, RES, energy storage, capacity scarcity, macroeconomics

  15. Solar-Powered Groundwater Pumping Systems for Nigerian Water Sheds

    OpenAIRE

    SODIKI, John; Sodiki, J. I.

    2016-01-01

    The paper presents an overview of the occurrence of different groundwater sheds, water quality, and availability in Nigeria. it also discussed the viability of solar-powered groundwater pumping systems in Nigeria. Applicable methods for system design and economic analysis are further outlined.

  16. System and method of detecting cavitation in pumps

    Science.gov (United States)

    Lu, Bin; Sharma, Santosh Kumar; Yan, Ting; Dimino, Steven A.

    2017-10-03

    A system and method for detecting cavitation in pumps for fixed and variable supply frequency applications is disclosed. The system includes a controller having a processor programmed to repeatedly receive real-time operating current data from a motor driving a pump, generate a current frequency spectrum from the current data, and analyze current data within a pair of signature frequency bands of the current frequency spectrum. The processor is further programmed to repeatedly determine fault signatures as a function of the current data within the pair of signature frequency bands, repeatedly determine fault indices based on the fault signatures and a dynamic reference signature, compare the fault indices to a reference index, and identify a cavitation condition in a pump based on a comparison between the reference index and a current fault index.

  17. Use of an Irrigation Pump System in Arthroscopic Procedures.

    Science.gov (United States)

    Hsiao, Mark S; Kusnezov, Nicholas; Sieg, Ryan N; Owens, Brett D; Herzog, Joshua P

    2016-05-01

    Since its inception, arthroscopic surgery has become widely adopted among orthopedic surgeons. It is therefore important to have an understanding of the basic principles of arthroscopy. Compared with open techniques, arthroscopic procedures are associated with smaller incisions, less structural damage, improved intra-articular visualization, less pain in the immediate postoperative period, and faster recovery for patients. Pump systems used for arthroscopic surgery have evolved over the years to provide improved intraoperative visualization. Gravity flow systems were described first and are still commonly used today. More recently, automated pump systems with pressure or dual pressure and volume control have been developed. The advantages of automated irrigation systems over gravity irrigation include a more consistent flow, a greater degree of joint distention, improved visualization especially with motorized instrumentation, decreased need for tourniquet use, a tamponade effect on bleeding, and decreased operative time. Disadvantages include the need for additional equipment with increased cost and maintenance, the initial learning curve for the surgical team, and increased risk of extra-articular fluid dissection and associated complications such as compartment syndrome. As image quality and pump systems improve, so does the list of indications including diagnostic and treatment modalities to address intra-articular pathology of the knee, shoulder, hip, wrist, elbow, and ankle joints. This article reviews the current literature and presents the history of arthroscopy, basic science of pressure and flow, types of irrigation pumps and their functions, settings, applications, and complications. [Orthopedics. 2016; 39(3):e474-e478.]. Copyright 2016, SLACK Incorporated.

  18. Dynamic damper pressure fluctuation in the pumping systems

    Directory of Open Access Journals (Sweden)

    O.V. Korolyov

    2016-05-01

    Full Text Available Inertial part of any devices and equipment (e.g., pumps, hung or mounted on the resilient frame and being under the influence of the disturbing force that works at a constant frequency, may be subject to fluctuations, especially near of the resonance area. For elimination these fluctuations, you can resort to the use of a dynamic damper. Aim: The aim of the work is an analytical study of various dynamic dampers to reduce pressure fluctuation problems in pumping systems. Materials and Methods: A comparative analysis of efficiency of functioning was carried out for two types of dynamic dampers - hydraulic and mechanical. Results: The technique for calculating of dynamic damper of fluid pressure fluctuations in the hydraulic and mechanical pumps is presented. Algorithms of calculations are reported to engineering applications and implemented in the production process. The calculations show that the use of dynamic mechanical dampers is expedient at high frequency pumps, and, with increasing frequency of the pump by 6 times, winning in the dimensions of the damper in 3.5 times.

  19. Evidences of turbulent mixing in multi-pumping flow systems.

    Science.gov (United States)

    Fortes, Paula R; Feres, Mario A; Sasaki, Milton K; Alves, Evandro R; Zagatto, Elias A G; Prior, João A V; Santos, João L M; Lima, José L F C

    2009-09-15

    Multi-pumping flow systems exploit pulsed flows delivered by solenoid pumps. Their improved performance rely on the enhanced radial mass transport inherent to the pulsed flow, which is a consequence of the establishment of vortices thus a tendency towards turbulent mixing. This paper presents several evidences of turbulent mixing in relation to pulsed flows, such as recorded peak shape, establishment of fluidized beds, exploitation of flow reversal, implementation of relatively slow chemical reactions and/or heating of the reaction medium. In addition, Reynolds number associated with the GO period of a pulsed flow is estimated and photographic images of dispersing samples flowing under laminar regime and pulsed flow conditions are presented.

  20. Highly sensitive vacuum ion pump current measurement system

    Science.gov (United States)

    Hansknecht, John Christopher [Williamsburg, VA

    2006-02-21

    A vacuum system comprising: 1) an ion pump; 2) power supply; 3) a high voltage DC--DC converter drawing power from the power supply and powering the vacuum pump; 4) a feedback network comprising an ammeter circuit including an operational amplifier and a series of relay controlled scaling resistors of different resistance for detecting circuit feedback; 5) an optional power block section intermediate the power supply and the high voltage DC--DC converter; and 6) a microprocessor receiving feedback information from the feedback network, controlling which of the scaling resistors should be in the circuit and manipulating data from the feedback network to provide accurate vacuum measurement to an operator.

  1. Comparative analysis of DG and solar PV water pumping system

    Science.gov (United States)

    Tharani, Kusum; Dahiya, Ratna

    2016-03-01

    Looking at present day electricity scenario, there is a major electricity crisis in rural areas. The farmers are still dependant on the monsoon rains for their irrigation needs and livestock maintenance. Some of the agrarian population has opted to use Diesel Generators for pumping water in their fields. But taking into consideration the economics and environmental conditions, the above choice is not suitable for longer run. An effort to shift from non-renewable sources such as diesel to renewable energy source such as solar has been highlighted. An approximate comparative analysis showing the life cycle costs of a PV pumping system with Diesel Generator powered water pumping is done using MATLAB/STMULTNK.

  2. System control fuzzy neural sewage pumping stations using genetic algorithms

    Directory of Open Access Journals (Sweden)

    Владлен Николаевич Кузнецов

    2015-06-01

    Full Text Available It is considered the system of management of sewage pumping station with regulators based on a neuron network with fuzzy logic. Linguistic rules for the controller based on fuzzy logic, maintaining the level of effluent in the receiving tank within the prescribed limits are developed. The use of genetic algorithms for neuron network training is shown.

  3. Numerical simulation of the sucker-rod pumping system

    Directory of Open Access Journals (Sweden)

    Oldrich Joel Romero

    2014-11-01

    Full Text Available The sucker rod pump is an artificial lift method frequently applied in onshore petroleum wells. This system can be described using a numerical simulation based on the behavior of a rod string. In the past, the elastic behavior of the rod string made it difficult to model the system. However, since the 1960s and with the advent of digital computers, it has been modeled numerically. The rod string be-haves like a slender bar, and thus, the propagation of elastic waves along the bar can be represented by a one-dimensional equation. Gibbs (1963 presented a mathematical model based on the wave equation, which is described on the basis of the analysis of forces on the rod string and is incorporated into a boundary value problem involving partial differential equations. The use of the finite differ-ence method allows for a numerical solution by the discretization of the wave equation developed in the mathematical formulation with appropriate boundary and initial conditions. This work presents a methodology for implementing an academic computer code that allows simulation of the upstroke and downstroke motion of the rod string described by the wave equation under ideal operating conditions, assuming a harmonic motion of the rod at one end and downhole pump at the other end. The goal of this study is to generate the downhole dynamometer card, an important and consolidated tool that controls the pump system by diagnosing oper-ational conditions of the downhole pump.

  4. Hourly simulation of a Ground-Coupled Heat Pump system

    Science.gov (United States)

    Naldi, C.; Zanchini, E.

    2017-01-01

    In this paper, we present a MATLAB code for the hourly simulation of a whole Ground-Coupled Heat Pump (GCHP) system, based on the g-functions previously obtained by Zanchini and Lazzari. The code applies both to on-off heat pumps and to inverter-driven ones. It is employed to analyse the effects of the inverter and of the total length of the Borehole Heat Exchanger (BHE) field on the mean seasonal COP (SCOP) and on the mean seasonal EER (SEER) of a GCHP system designed for a residential house with 6 apartments in Bologna, North-Center Italy, with dominant heating loads. A BHE field with 3 in line boreholes is considered, with length of each BHE either 75 m or 105 m. The results show that the increase of the BHE length yields a SCOP enhancement of about 7%, while the SEER remains nearly unchanged. The replacement of the on-off heat pump by an inverter-driven one yields a SCOP enhancement of about 30% and a SEER enhancement of about 50%. The results demonstrate the importance of employing inverter-driven heat pumps for GCHP systems.

  5. Flathead Electric Cooperative Facility Geothermal Heat Pump System Upgrade.

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [Oak Ridge National Lab

    2014-06-01

    High initial cost and lack of public awareness of ground source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights findings of a case study of one of the ARRA-funded GSHP demonstration projects, which is a heating only central GSHP system using shallow aquifer as heat source and installed at a warehouse and truck bay at Kalispell, MT. This case study is based on the analysis of measured performance data, utility bills, and calculations of energy consumptions of conventional central heating systems for providing the same heat outputs as the central GSHP system did. The evaluated performance metrics include energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of GSHP system compared with conventional heating systems. This case study also identified areas for reducing uncertainties in performance evaluation, improving operational efficiency, and reducing installed cost of similar GSHP systems in the future. Publication of ASHRAE at the annual conference in Seattle June 2014.

  6. Flathead Electric Cooperative Facility Geothermal Heat Pump System Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [Oak Ridge National Lab

    2014-06-01

    High initial cost and lack of public awareness of ground source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights findings of a case study of one of the ARRA-funded GSHP demonstration projects, which is a heating only central GSHP system using shallow aquifer as heat source and installed at a warehouse and truck bay at Kalispell, MT. This case study is based on the analysis of measured performance data, utility bills, and calculations of energy consumptions of conventional central heating systems for providing the same heat outputs as the central GSHP system did. The evaluated performance metrics include energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of GSHP system compared with conventional heating systems. This case study also identified areas for reducing uncertainties in performance evaluation, improving operational efficiency, and reducing installed cost of similar GSHP systems in the future. Publication of ASHRAE at the annual conference in Seattle.

  7. Entropy, pumped-storage and energy system finance

    Science.gov (United States)

    Karakatsanis, Georgios

    2015-04-01

    Pumped-storage holds a key role for integrating renewable energy units with non-renewable fuel plants into large-scale energy systems of electricity output. An emerging issue is the development of financial engineering models with physical basis to systematically fund energy system efficiency improvements across its operation. A fundamental physically-based economic concept is the Scarcity Rent; which concerns the pricing of a natural resource's scarcity. Specifically, the scarcity rent comprises a fraction of a depleting resource's full price and accumulates to fund its more efficient future use. In an integrated energy system, scarcity rents derive from various resources and can be deposited to a pooled fund to finance the energy system's overall efficiency increase; allowing it to benefit from economies of scale. With pumped-storage incorporated to the system, water upgrades to a hub resource, in which the scarcity rents of all connected energy sources are denominated to. However, as available water for electricity generation or storage is also limited, a scarcity rent upon it is also imposed. It is suggested that scarcity rent generation is reducible to three (3) main factors, incorporating uncertainty: (1) water's natural renewability, (2) the energy system's intermittent components and (3) base-load prediction deviations from actual loads. For that purpose, the concept of entropy is used in order to measure the energy system's overall uncertainty; hence pumped-storage intensity requirements and generated water scarcity rents. Keywords: pumped-storage, integration, energy systems, financial engineering, physical basis, Scarcity Rent, pooled fund, economies of scale, hub resource, uncertainty, entropy Acknowledgement: This research was funded by the Greek General Secretariat for Research and Technology through the research project Combined REnewable Systems for Sustainable ENergy DevelOpment (CRESSENDO; grant number 5145)

  8. Design and control of a standalone PV water pumping system

    Directory of Open Access Journals (Sweden)

    Essam E. Aboul Zahab

    2017-09-01

    Full Text Available Water resources are vital for satisfying human needs. However, almost one-fifth of the world’s population – about 1.2 billion people – live in areas where water is physically rare. One quarter of the global population also live in developing countries that face water shortages. This paper presents standalone PV water pumping system. Photovoltaic (PV is the main power source, and lead acid batteries are used as energy storage system, to supply a water pump driven by a BLDC motor. The proposed control strategy consists of three control units. The first unit is to control the speed and hysteresis current controller for BLDC motor. The maximum power point tracking (MPPT is the second control unit, and the battery charging/discharging system is controlled by the third controller. The simulation results show the effectiveness and the good efficiency of the proposed system.

  9. Multi-pumping flow systems: the potential of simplicity.

    Science.gov (United States)

    Santos, João L M; Ribeiro, Marta F T; Dias, Ana C B; Lima, José L F C; Zagatto, Elias E A

    2007-09-26

    Nowadays, the trend towards more compact, smarter and simpler devices is generally recognized as one of the most challenging aspects in the development of analytical instrumentation. Modern flow-based procedures do not escape this tendency. The level of integration and automation and the operational functionality of Multi-pumping flow systems (MPFS) would, in most of the situations, meet this requirement. The essential elements of MPFS are multiple solenoid actuated micro-pumps strategically positioned in the flow manifold, which are accountable for solutions insertion, propelling and commutation, conditioning the establishment and subsequent detection of the reaction zone. Being the only active components of the flow manifold they provide a great operational simplicity and assure a straightforward run-time control of important analytical variables. Moreover, the reduction of active components minimizes the probability of occurrence of equipment failures, malfunctions or errors. The low size and low cost of solenoid micro-pumps make them ideal tools to build up compact environmentally friendly analytical systems, which are characterized by low solutions consumptions and the minimisation of hazardous waste generation. Furthermore, the reproducible pulsed flowing stream produced by micro-pumps actuation has proven to be a valuable feature regarding sample/reagent mixing and reaction zone homogenisation.

  10. Principle and characteristics of heat pump air conditioning system

    Science.gov (United States)

    Liu, Lu

    2017-05-01

    The application of heat pump technology in building energy saving has been paid more and more attention. By analyzing the principle and characteristics of air source heat pump, ground source heat pump and water source heat pump, the problems and prospects of heat pump technology in China are pointed out.

  11. TEAMS Model for the HPGF LN2 Pump System Diagnostic Utility Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The engineering design group upgraded the liquid nitrogen pump system at the HPGF. The pump system supports the site-wide liquid nitrogen supply and its operation is...

  12. Calculation methods for SPF for heat pump systems for comparison, system choice and dimensioning

    Energy Technology Data Exchange (ETDEWEB)

    Nordman, Roger; Andersson, Kajsa; Axell, Monica; Lindahl, Markus

    2010-09-15

    In this project, results from field measurements of heat pumps have been collected and summarised. Also existing calculation methods have been compared and summarised. Analyses have been made on how the field measurements compare to existing calculation models for heat pumps Seasonal Performance Factor (SPF), and what deviations may depend on. Recommendations for new calculation models are proposed, which include combined systems (e.g. solar - HP), capacity controlled heat pumps and combined DHW and heating operation

  13. Advanced control for ground source heat pump systems

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, Patrick [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    Ground source heat pumps (GSHP), also known as geothermal heat pumps (GHP), are proven advanced HVAC systems that utilize clean and renewable geothermal energy, as well as the massive thermal storage capacity of the ground, to provide space conditioning and water heating for both residential and commercial buildings. GSHPs have higher energy efficiencies than conventional HVAC systems. It is estimated, if GSHPs achieve a 10% market share in the US, in each year, 0.6 Quad Btu primary energy consumption can be saved and 36 million tons carbon emissions can be avoided (Liu et al. 2017). However, the current market share of GSHPs is less than 1%. The foremost barrier preventing wider adoption of GSHPs is their high installation costs. To enable wider adoption of GSHPs, the costeffectiveness of GSHP applications must be improved.

  14. Thermally conductive cementitious grout for geothermal heat pump systems

    Science.gov (United States)

    Allan, Marita

    2001-01-01

    A thermally conductive cement-sand grout for use with a geothermal heat pump system. The cement sand grout contains cement, silica sand, a superplasticizer, water and optionally bentonite. The present invention also includes a method of filling boreholes used for geothermal heat pump systems with the thermally conductive cement-sand grout. The cement-sand grout has improved thermal conductivity over neat cement and bentonite grouts, which allows shallower bore holes to be used to provide an equivalent heat transfer capacity. In addition, the cement-sand grouts of the present invention also provide improved bond strengths and decreased permeabilities. The cement-sand grouts can also contain blast furnace slag, fly ash, a thermoplastic air entraining agent, latex, a shrinkage reducing admixture, calcium oxide and combinations thereof.

  15. Efficiency improvement for wind energy pumped storage systems

    DEFF Research Database (Denmark)

    Forcos, A.; Marinescu, C.; Teodorescu, Remus

    2011-01-01

    Integrating wind energy into the grid may raise stability problems. Solutions for avoiding these situations are studied and energy storage methods are suitable for balancing the energy between the wind turbine and grid. In this paper, an autonomous wind turbine pumped storage system is presented....... The focus of this paper is to improve the efficiency of this system, which is small at low power levels. The driving motorpump group of the storage system is the key point presented in this paper for efficiency improving. Two control methods, experimentally implemented for induction machine are presented......, and the comparison of the system efficiencies highlights the improvement of the proposed control method....

  16. Selection of parameters for mud pumps used for HDD Systems

    Directory of Open Access Journals (Sweden)

    Jan Ziaja

    2006-10-01

    Full Text Available Design solutions of rigs used for HDD are presented in the paper. HDD devices are classified on the basis of presented criteria, and then a division of rigs was proposed. The principles of determining technological parameters of piston mud pumps for HDD are presented. The principles of determining volume flow rate for an arbitrary rheological model of drilling mud are discussed. The dependences enabling a calculation of resistance of drilling fluid flow in a circulation system are also presented.

  17. Multi-pumping flow systems: an automation tool.

    Science.gov (United States)

    Lima, José L F C; Santos, João L M; Dias, Ana C B; Ribeiro, Marta F T; Zagatto, Elias A G

    2004-12-15

    Multi-pumping flow systems (MPFS) are one of the most recent developments in terms of the design, conception and implementation of continuous flow methodologies, for sample and reagent handling and for the automation of analytical procedures. Based on the utilisation of multiple solenoid micro-pumps they enable the configuring of fully automated and easily controlled and operated analytical systems since all the fundamental operations involved in carrying out a sample analysis, including sample insertion, reagent addition and signal measurement could be carried out by the same manifold component, reducing the number of system parts and minimising its control or the occurrence of mal-functions. On the other hand, micro-pumps actuation produce a pulsed flow characterised by a chaotic movement of the solutions, which contributes to a fast sample/reagent homogenisation with low axial dispersion yielding improved analytical signals. The combination of such advantageous features resulted in simple, compact, versatile, fast, low-cost analytical procedures, exhibiting low reagent and low sample consumption, reducing the production of undesirable wastes and minimising operator intervention.

  18. Method and system for homogenizing diode laser pump arrays

    Science.gov (United States)

    Bayramian, Andy J

    2013-10-01

    An optical amplifier system includes a diode pump array including a plurality of semiconductor diode laser bars disposed in an array configuration and characterized by a periodic distance between adjacent semiconductor diode laser bars. The periodic distance is measured in a first direction perpendicular to each of the plurality of semiconductor diode laser bars. The diode pump array provides a pump output propagating along an optical path and characterized by a first intensity profile measured as a function of the first direction and having a variation greater than 10%. The optical amplifier system also includes a diffractive optic disposed along the optical path. The diffractive optic includes a photo-thermo-refractive glass member. The optical amplifier system further includes an amplifier slab having an input face and position along the optical path and separated from the diffractive optic by a predetermined distance. A second intensity profile measured at the input face of the amplifier slab as a function of the first direction has a variation less than 10%.

  19. COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Zhu; Yong X. Tao

    2011-11-01

    In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

  20. Test System for Node Efficiency of Progressive Cavity Pump Based on Wireless Communication Technology

    National Research Council Canada - National Science Library

    Tingjun Yan; Haoqiang Ti; Xianmin Wu

    2013-01-01

      In order to acquire the data of the energy consumption and operation efficiency of progressive cavity pump wells, a new test system for node efficiency of progressive cavity pump based on wireless...

  1. Energy system investment model incorporating heat pumps with thermal storage in buildings and buffer tanks

    DEFF Research Database (Denmark)

    Hedegaard, Karsten; Balyk, Olexandr

    2013-01-01

    Individual compression heat pumps constitute a potentially valuable resource in supporting wind power integration due to their economic competitiveness and possibilities for flexible operation. When analysing the system benefits of flexible heat pump operation, effects on investments should be ta...

  2. Chemical heat pump and chemical energy storage system

    Science.gov (United States)

    Clark, Edward C.; Huxtable, Douglas D.

    1985-08-06

    A chemical heat pump and storage system employs sulfuric acid and water. In one form, the system includes a generator and condenser, an evaporator and absorber, aqueous acid solution storage and water storage. During a charging cycle, heat is provided to the generator from a heat source to concentrate the acid solution while heat is removed from the condenser to condense the water vapor produced in the generator. Water is then stored in the storage tank. Heat is thus stored in the form of chemical energy in the concentrated acid. The heat removed from the water vapor can be supplied to a heat load of proper temperature or can be rejected. During a discharge cycle, water in the evaporator is supplied with heat to generate water vapor, which is transmitted to the absorber where it is condensed and absorbed into the concentrated acid. Both heats of dilution and condensation of water are removed from the thus diluted acid. During the discharge cycle the system functions as a heat pump in which heat is added to the system at a low temperature and removed from the system at a high temperature. The diluted acid is stored in an acid storage tank or is routed directly to the generator for reconcentration. The generator, condenser, evaporator, and absorber all are operated under pressure conditions specified by the desired temperature levels for a given application. The storage tanks, however, can be maintained at or near ambient pressure conditions. In another form, the heat pump system is employed to provide usable heat from waste process heat by upgrading the temperature of the waste heat.

  3. Heat pump system promises relief for asthma sufferers

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, G.

    1992-01-01

    A new energy efficient system for heating and ventilating domestic dwellings is being evaluated by E. A. Technology - a major electricity utilisation and distribution research company in the U.K. As well as providing enhanced comfort levels at lower operating costs, the use of the new heat pump system from E. A. Technology could, it is believed, prove to be an effective means of controlling the numbers and activity of the common house dust mite - one of the principal causes of asthma attacks. (author).

  4. DESIGN AND ANALYSIS OF GATING SYSTEM FOR PUMP CASING

    OpenAIRE

    N.JAYAKUMAR; Dr.S.MOHANAMURUGAN; Dr.R.RAJAVEL

    2014-01-01

    Design of gating system is vital in any molding or casting processes, in order to get defect free components. As far as the casting of pump casing is concerned, finding the “Hot Spot” is very important, as most of the casting defects occur at the “Hot spot”. “Hot Spot” is the part of casting that gets solidified last. The “Hot Spot” usually occurs at the thickest cross section of the casting. By simulation, the most appropriate location is selected for incorporating the Gating system (gate...

  5. Variable flow controls of closed system pumps for energy savings in maritime power systems

    DEFF Research Database (Denmark)

    Su, Chun-Lien; Liao, Chi-Hsiang; Chou, Tso-Chu

    2016-01-01

    Pumps are extensively used in maritime industries as marine vessels utilize a wide range of pumps and pumping techniques to transfer and distribute all types of air and fluids. The electrical energy consumed by the various motors accounts for about 70% of a vessel’s total power consumption......, and this presents a problem in unique marine environments. Such situations are especially conducive to energy-saving strategies using variable frequency drives (VFDs) in centrifugal load service. This paper presents the design and results of applying variable frequency constant pressure technology in closed system...... pumps on marine vessels. The existing problem of traditional control methods for closed system pumps is analyzed and a mathematical model for variable flow controls with the appropriate control settings is derived. The performance of the proposed method is demonstrated and verified through experimental...

  6. Magnetocaloric heat pump device, a heating or cooling system and a magnetocaloric heat pump assembly

    DEFF Research Database (Denmark)

    2014-01-01

    The invention provides a magnetocaloric heat pump device, comprising a magnetocaloric bed; a magnetic field source, the magnetocaloric bed and the magnetic field source being arranged to move relative to each other so as to generate a magnetocaloric refrigeration cycle within the heat pump, wherein...

  7. A method of applying two-pump system in automatic transmissions for energy conservation

    Directory of Open Access Journals (Sweden)

    Peng Dong

    2015-06-01

    Full Text Available In order to improve the hydraulic efficiency, modern automatic transmissions tend to apply electric oil pump in their hydraulic system. The electric oil pump can support the mechanical oil pump for cooling, lubrication, and maintaining the line pressure at low engine speeds. In addition, the start–stop function can be realized by means of the electric oil pump; thus, the fuel consumption can be further reduced. This article proposes a method of applying two-pump system (one electric oil pump and one mechanical oil pump in automatic transmissions based on the forward driving simulation. A mathematical model for calculating the transmission power loss is developed. The power loss transfers to heat which requires oil flow for cooling and lubrication. A leakage model is developed to calculate the leakage of the hydraulic system. In order to satisfy the flow requirement, a flow-based control strategy for the electric oil pump is developed. Simulation results of different driving cycles show that there is a best combination of the size of electric oil pump and the size of mechanical oil pump with respect to the optimal energy conservation. Besides, the two-pump system can also satisfy the requirement of the start–stop function. This research is extremely valuable for the forward design of a two-pump system in automatic transmissions with respect to energy conservation and start–stop function.

  8. Issues in offshore platform research - Part 1: Semi-submersibles

    Science.gov (United States)

    Sharma, R.; Kim, Tae-Wan; Sha, O. P.; Misra, S. C.

    2010-09-01

    Availability of economic and efficient energy resources is crucial to a nation's development. Because of their low cost and advancement in drilling and exploration technologies, oil and gas based energy systems are the most widely used energy source throughout the world. The inexpensive oil and gas based energy systems are used for everything, i.e., from transportation of goods and people to the harvesting of crops for food. As the energy demand continues to rise, there is strong need for inexpensive energy solutions. An offshore platform is a large structure that is used to house workers and machinery needed to drill wells in the ocean bed, extract oil and/or natural gas, process the produced fluids, and ship or pipe them to shore. Depending on the circumstances, the offshore platform can be fixed (to the ocean floor) or can consist of an artificial island or can float. Semi-submersibles are used for various purposes in offshore and marine engineering, e.g. crane vessels, drilling vessels, tourist vessels, production platforms and accommodation facilities, etc. The challenges of deepwater drilling have further motivated the researchers to design optimum choices for semi-submersibles for a chosen operating depth. In our series of eight papers, we discuss the design and production aspects of all the types of offshore platforms. In the present part I, we present an introduction and critical analysis of semi-submersibles.

  9. Issues in offshore platform research - Part 1: Semi-submersibles

    Directory of Open Access Journals (Sweden)

    R. Sharma

    2010-09-01

    Full Text Available Availability of economic and efficient energy resources is crucial to a nation's development. Because of their low cost and advancement in drilling and exploration technologies, oil and gas based energy systems are the most widely used energy source throughout the world. The inexpensive oil and gas based energy systems are used for everything, i.e., from transportation of goods and people to the harvesting of crops for food. As the energy demand continues to rise, there is strong need for inexpensive energy solutions. An offshore platform is a large structure that is used to house workers and machinery needed to drill wells in the ocean bed, extract oil and/or natural gas, process the produced fluids, and ship or pipe them to shore. Depending on the circumstances, the offshore platform can be fixed (to the ocean floor or can consist of an artificial island or can float. Semi-submersibles are used for various purposes in offshore and marine engineering, e.g. crane vessels, drilling vessels, tourist vessels, production platforms and accommodation facilities, etc. The challenges of deepwater drilling have further motivated the researchers to design optimum choices for semi-submersibles for a chosen operating depth. In our series of eight papers, we discuss the design and production aspects of all the types of offshore platforms. In the present part I, we present an introduction and critical analysis of semi-submersibles.

  10. Corrosion failure of Ni-resist pumping system components

    Energy Technology Data Exchange (ETDEWEB)

    Tatarov, A.; Gareau, F. [Skystone Engineering, Calgary, AB (Canada); Bondarchuk, D.; Cymbol, B. [Apache Canada Ltd., Calgary, AB (Canada)

    2010-07-01

    This paper discussed a failure analysis conducted after the failure of a new high pressure horizontal pumping system that was installed as part of an oilfield injection system. The pump impellers failed after less than a year in service due to the corrosion and cracking. The components were constructed from Ni-Resist type 1, a commonly used material in corrosive environments, as well as a polytetrafluoroethylene (PTFE) surface coating. A visual examination, X-ray diffraction, optical microscopy, scanning electron microscopy (SEM) and a metallographic examination did not demonstrate signs of impingement corrosion, abrasive wear, or cavitation. Results of the study showed that the root cause of the corrosion failure was the permeability of the coating, and the unprotected surfaces of the Ni-Resist material, which did not have a protective passive film. The system was found to contain an un-removed surface scale of sand and ceramics as well as materials left over from the manufacturing process. A thorough cleaning of the system's surfaces would have allowed a passive layer to form on the surface and prevented the failure from occurring. 2 refs., 5 figs.

  11. Control of Electric Drives in the Best Efficiency Region of Pumping System

    Directory of Open Access Journals (Sweden)

    Bakman Ilja

    2014-10-01

    Full Text Available The paper concentrates on improving the efficiency of the pumping system in which pumps are run by variable speed drives. The method is applicable to system consisting of several centrifugal pumps. Problems arising from running the pumps outside the optimal efficiency region are discussed. Common principles of operation and control of typical boosting pumping station are represented. Methods of regulation of productivity of the system are described. The proposed method is based on prediction of future efficiency of pumps before making adjustments of pumping system productivity. The proposed method is basing on tracking the working point of pump on efficiency graph. Monitoring the location of working point vs. efficiency graph enables to evaluate its current and future distances from the best efficiency point of the pump. Knowing the current number of running pumps it is possible to predict the location of working point after adjustment of productivity of the system. Ability to predict the increase or decrease of efficiency enables to enhance the adjustment of productivity of the system. Methods of graphical analysis of working state of the pumping system are representing topic for future research.

  12. Pumping systems characterization; Caracterizacion de los sistemas de bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Torres Gutierrez, R. [Eficiencia Energetica, S.A. de C.V., Mexico, D. F. (Mexico)

    1995-12-31

    In this paper the characterization of the pumping systems is discussed, and an explanation is given of the need of evaluating in detail the possibility of implementing the frequency variators as an option for energy conservation, explaining how the simple use of the similarity or affinity laws lead to over-estimate the saving. [Espanol] En este articulo se describe la caracterizacion de los sistemas de bombeo y se explica la necesidad de evaluar en detalle la posibilidad de implementacion de variadores de frecuencia, como una alternativa para el ahorro de energia, explicando como el simple uso de las leyes de semejanza o afinidad llevan a sobre-evaluar los ahorros.

  13. Geothermal pump down-hole energy regeneration system

    Science.gov (United States)

    Matthews, Hugh B.

    1982-01-01

    Geothermal deep well energy extraction apparatus is provided of the general kind in which solute-bearing hot water is pumped to the earth's surface from a subterranean location by utilizing thermal energy extracted from the hot water for operating a turbine motor for driving an electrical power generator at the earth 3 s surface, the solute bearing water being returned into the earth by a reinjection well. Efficiency of operation of the total system is increased by an arrangement of coaxial conduits for greatly reducing the flow of heat from the rising brine into the rising exhaust of the down-well turbine motor.

  14. Role of pump hydro in electric power systems

    Science.gov (United States)

    Bessa, R.; Moreira, C.; Silva, B.; Filipe, J.; Fulgêncio, N.

    2017-04-01

    This paper provides an overview of the expected role that variable speed hydro power plants can have in future electric power systems characterized by a massive integration of highly variable sources. Therefore, it is discussed the development of a methodology for optimising the operation of hydropower plants under increasing contribution from new renewable energy sources, addressing the participation of a hydropower plant with variable speed pumping in reserve markets. Complementarily, it is also discussed the active role variable speed generators can have in the provision of advanced frequency regulation services.

  15. Computer system design description for the spare pump mini-dacs data acquisition and control system

    Energy Technology Data Exchange (ETDEWEB)

    Vargo, G.F. Jr.

    1994-09-29

    The attached document outlines the computer software design for the mini data acquisition and control system (DACS), that supports the testing of the spare pump for Tank 241-SY-101, at the maintenance and storage facility (MASF).

  16. Impeller-pump model derived from conservation laws applied to the simulation of the cardiovascular system coupled to heart-assist pumps.

    Science.gov (United States)

    Shi, Yubing; Korakianitis, Theodosios

    2018-02-01

    Previous numerical models of impeller pumps for ventricular assist devices utilize curve-fitted polynomials to simulate experimentally-obtained pressure difference versus flow rate characteristics of the pumps, with pump rotational speed as a parameter. In this paper the numerical model for the pump pressure difference versus flow rate characteristics is obtained by analytic derivation. The mass, energy and angular momentum conservation laws are applied to the working fluid passing through the impeller geometry and coupled with the turbomachine's velocity diagram. This results in the construction of a pressure difference versus flow rate characteristic for the specific pump geometry, with pump rotational speed as parameter. Overall this model allows modifications of the pump geometry, so that the pump avoids undesirable operating conditions, such as regurgitant flow. The HeartMate III centrifugal pump is used as an example to demonstrate the application of the technique. The parameterised numerical model for HeartMate III derived by this technique is coupled with a numerical model for the human cardiovascular system, and the combination is used to investigate the cardiovascular response under different conditions of impeller pump support. Conditions resulting in regurgitant pump flow, the pump resulting in aortic valve closure and taking over completely the pumping action from the diseased heart, and inner ventricular wall suction at pump inlet are predicted by the model. The simulation results suggest that for normal HeartMate III operation the pump speed should be maintained between 3,100 and 4,500 rpm to avoid regurgitant pump flow and ventricular suction. To obtain optimal overall cardiovascular system plus pump response, the pump operating speed should be 3,800 rpm. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Development of a heat pump thermal control system for spacecraft

    Science.gov (United States)

    Ogushi, T.; Murakami, M.; Tanaka, N.; Koda, T.; Hirai, T.

    This paper describes a concept of a thermal control system that has three operating modes, i.e., heat pump operation, liquid-pumped two-phase fluid loop operation, and their combination. The system is controlled to maintain desired temperature levels of payloads in the presence of wide fluctuation of thermal loads. The way of system-control and the key elements, such as a cold plate, an accumulator, and a space-use compressor are investigated. Boiling heat transfer coefficient of two-phase flow going upward or downward in a vertical evaporator pipe is investigated experimentally for predicting the coefficient in the cold plate in reduced gravity. The empirical results indicate that annular flow is dominant flow regime in space and the heat transfer coefficient is predictable from the correlation by Chen. A prototype oil-free compressor for space use is constructed, and the performance and durability are experimentally investigated. Sufficient performance and more than 2500 hours of continuous operation was obtained.

  18. Magnetohydrodynamic pump with a system for promoting flow of fluid in one direction

    Science.gov (United States)

    Lemoff, Asuncion V [Union City, CA; Lee, Abraham P [Irvine, CA

    2010-07-13

    A magnetohydrodynamic pump for pumping a fluid. The pump includes a microfluidic channel for channeling the fluid, a MHD electrode/magnet system operatively connected to the microfluidic channel, and a system for promoting flow of the fluid in one direction in the microfluidic channel. The pump has uses in the medical and biotechnology industries for blood-cell-separation equipment, biochemical assays, chemical synthesis, genetic analysis, drug screening, an array of antigen-antibody reactions, combinatorial chemistry, drug testing, medical and biological diagnostics, and combinatorial chemistry. The pump also has uses in electrochromatography, surface micromachining, laser ablation, inkjet printers, and mechanical micromilling.

  19. Performance of a small wind powered water pumping system

    Science.gov (United States)

    Lorentz helical pumps (Henstedt-Ulzburg, Germany) have been powered by solar energy for remote water pumping applications for many years, but from October 2005 to March 2008 a Lorentz helical pump was powered by wind energy at the USDA-ARS Conservation and Production Research Laboratory (CPRL) near ...

  20. Off-pump CABG surgery reduces systemic inflammation compared with on-pump surgery but does not change systemic endothelial responses : a prospective randomized study

    NARCIS (Netherlands)

    Jongman, Rianne M.; Zijlstra, Jan G.; Kok, Wendelinde F.; van Harten, Annemarie E.; Mariani, Massimo A.; Moser, Jill; Struys, Michel M. R. F.; Absalom, Anthony R.; Molema, Grietje; Scheeren, Thomas W. L.; van Meurs, Matijs

    Coronary artery bypass graft (CABG) surgery can result in severe postoperative organ failure. During CABG surgery, cardiopulmonary bypass (CPB) with cardiac arrest is often used (on-pump CABG), which often results in a systemic inflammatory response. To reduce this inflammatory response, off-pump

  1. Coherent Excitations Induced by Pumping a Mott System

    Science.gov (United States)

    Wang, Yao; Claassen, Martin; Moritz, Brian; Devereaux, Thomas

    Time-domain or non-equilibrium dynamics of correlated materials has attracted attention due to the possibility to characterize, tune and create complex ordered states. To understand how single and multi-particle excitations develop in a strongly-correlated systems during a pulsed pump, we perform a time-resolved exact-diagonalization study on a single-band Hubbard model. Starting from the Mott insulator at half-filling, we observe the suppression of antiferromagnetism and development of low-energy charge excitations through a series of Floquet-like sidebands. By correlating with the numerically evaluated single-particle spectra in non-equilibrium, the transient dynamics of multi-particle excitations can be attributed to the interplay between virtual Floquet sidebands and change of density of states due to the existence of strong correlations. The autocorrelation of this time-dependent spectral function reflects that it is the resonance of floquet states and upper Hubbard band that causes the remnant change of charge and spin excitations. This nonperturbative, nonequilibrium and nonstatic study reveals the underlying physical process while correlated electrons are pumped in experiment and provide the opportunity of designing nonequilibrium state of matter by a short pulsed laser.

  2. Skeletal Muscle Pump Drives Control of Cardiovascular and Postural Systems

    Science.gov (United States)

    Verma, Ajay K.; Garg, Amanmeet; Xu, Da; Bruner, Michelle; Fazel-Rezai, Reza; Blaber, Andrew P.; Tavakolian, Kouhyar

    2017-03-01

    The causal interaction between cardio-postural-musculoskeletal systems is critical in maintaining postural stability under orthostatic challenge. The absence or reduction of such interactions could lead to fainting and falls often experienced by elderly individuals. The causal relationship between systolic blood pressure (SBP), calf electromyography (EMG), and resultant center of pressure (COPr) can quantify the behavior of cardio-postural control loop. Convergent cross mapping (CCM) is a non-linear approach to establish causality, thus, expected to decipher nonlinear causal cardio-postural-musculoskeletal interactions. Data were acquired simultaneously from young participants (25 ± 2 years, n = 18) during a 10-minute sit-to-stand test. In the young population, skeletal muscle pump was found to drive blood pressure control (EMG → SBP) as well as control the postural sway (EMG → COPr) through the significantly higher causal drive in the direction towards SBP and COPr. Furthermore, the effect of aging on muscle pump activation associated with blood pressure regulation was explored. Simultaneous EMG and SBP were acquired from elderly group (69 ± 4 years, n = 14). A significant (p = 0.002) decline in EMG → SBP causality was observed in the elderly group, compared to the young group. The results highlight the potential of causality to detect alteration in blood pressure regulation with age, thus, a potential clinical utility towards detection of fall proneness.

  3. Expert system for the diagnosis of the condition and performance of centrifugal pumps

    Energy Technology Data Exchange (ETDEWEB)

    Jantunen, E.; Vaehae-Pietilae, K.; Pesonen, K. [Technical Research Centre of Finland, Manufacturing Technology, Espoo (Finland)

    1997-12-31

    A brief description of the results of a study concerning the maintenance and downtime costs in Finnish pumping is given. The leakage of seals was found to be the fault that causes the highest downtime and maintenance costs. A small laboratory arrangement has been used to test the effectiveness of various condition monitoring methods. This information has been used in the development of a diagnostic expert system called CEPDIA, which can be used for diagnosing the condition of a pump and its components. The diagnosis is based on measuring results obtained from sensors and on information about maintenance actions carried out with the pump and its components. The principles of the CEPDIA expert system are described. A database is included in the system for handling and saving the measurement results, technical information on the pumps and maintenance actions carried out with the pumps. The diagnosis can also be based on vibration signature analysis, which is quite effective in determining which fault is the actual cause of malfunction of the pump or its components. CEPDIA can also be used to calculate of the efficiency of the electrical motor and the pump. CEPDIA has been tested in the diagnosis of 63 pumps. The average efficiency in pumping was less than 40 %, and more than 10 % of the pumps were pumping with less than 10 % efficiency. (orig.) 11 refs.

  4. Induction generator-induction motor wind-powered pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, M.S.; Lyra, R.O.C.; Silva, S.R. [CPDEE - UFMG, Belo Horizonte (Brazil)

    1997-12-31

    The energy storage matter plays an important role in wind-electric conversion systems for isolated applications. Having that in mind, two different approaches can be basically considered: either the immediate conversion of the generated electric energy, as in a water pumping system or electric energy storage for later use, as in a battery charging system. Due to some features such as no need of an external reactive power source and, sometimes, a gearbox, permanent-magnet synchronous generators have been broadly used in low rated power isolated systems. Despite that, system performance can be affected when the generator is feeding an inductive load (e.g., an induction motor) under variable-speed-variable-frequency operational conditions. Since there is no effective flux control, motor overload may occur at high wind speeds. Thus, good system performance can be obtained through additional control devices which may increase system cost. Although being rugged and cheap, induction machines always work as a reactive power drain; therefore, they demand an external reactive power source. Considering that, reactive static compensators appear as an attractive alternative to the cost x performance problem. In addition to that, different control strategies can be used so that system performance can be improved.

  5. Experimental investigations on solar heating/heat pump systems for single family houses

    DEFF Research Database (Denmark)

    Andersen, Elsa; Perers, Bengt

    In the period 2013-2017 the project “Experimental investigations on solar heat pump systems for single family houses” is carried out at Department of Civil Engineering, Technical University of Denmark. The aim of this project is to increase the knowledge of the heat and mass transfer in the combi......In the period 2013-2017 the project “Experimental investigations on solar heat pump systems for single family houses” is carried out at Department of Civil Engineering, Technical University of Denmark. The aim of this project is to increase the knowledge of the heat and mass transfer...... in the combined solar heating/heat pump system type when the heat pump makes use of a horizontal ground source heat exchanger. The knowledge is gained by experimental investigations on a solar heating/heat pump system and forms the basis for improved marketed combined solar heating/heat pump systems....

  6. 78 FR 77649 - Notification of Proposed Production Activity, Xylem Water Systems USA LLC, Subzone 37D...

    Science.gov (United States)

    2013-12-24

    ... Foreign-Trade Zones Board Notification of Proposed Production Activity, Xylem Water Systems USA LLC, Subzone 37D, (Centrifugal, Submersible Pumps and Related Components), Auburn, New York Xylem Water Systems USA LLC (Xylem), operator of Subzone 37D, submitted a notification of proposed production activity to...

  7. Maldistribution in airewater heat pump evaporators. Part 1: Effects on evaporator, heat pump and system level

    DEFF Research Database (Denmark)

    Mader, Gunda; Palm, Björn; Elmegaard, Brian

    2015-01-01

    This paper presents an approach to quantify the effect of evaporator maldistribution onoperating costs of air-water heat pumps. In the proposed simulation model maldistributionis induced by two parameters describing refrigerant phase and air flow distribution.Annual operating costs are calculated...... based on heat pump performance at distinct operatingconditions. Results show that percentage increase of operating costs is similar for thethree considered climate zones, even though the effect of maldistribution on heat pumpperformance varies with operating conditions. Differences in terms of absolute...

  8. An analysis of water-to-air heat pump systems for use in government facilities

    Science.gov (United States)

    Fretzs, R. G.

    1980-09-01

    Energy consumption is an important issue for government managers. Examined in this thesis is one source of potential energy savings: a method of heating and cooling buildings. Water-to-air heat pumps are analyzed and cost comparisons to conventional heating/cooling systems (gas, fuel oil, electric resistance, and air-to-air heat pumps) are made. The theory of heat pump technology is presented to show how water source heat pumps achieve improved efficiencies over conventional systems. Sources of and disposal of water to support the systems are discussed. Cost comparisons are presented based on computer simulations and fuel cost graphs. Twenty-one percent of U.S. energy consumption is used to heat and cool buildings. Water-to-air heat pumps provide a 30-50 percent savings over other systems. Therefore, a potential 10 percent savings in total energy consumption exists through the use of water source heat pumps.

  9. Role of Pumped Storage Hydro Resources in Electricity Markets and System Operation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ela, E.; Kirby, B.; Botterud, A.; Milostan, C.; Krad, I.; Koritarov, V.

    2013-05-01

    The most common form of utility- sized energy storage system is the pumped storage hydro system. Originally, these types of storage systems were economically viable simply because they displace more expensive generating units. However, over time, as those expensive units became more efficient and costs declined, pumped hydro storage units no longer have the operational edge. As a result, in the current electricity market environment, pumped storage hydro plants are struggling. To offset this phenomenon, certain market modifications should be addressed. This paper will introduce some of the challenges faced by pumped storage hydro plants in today's markets and purpose some solutions to those problems.

  10. The maximum overall coefficient of performance of a solar-driven heat pump system

    Science.gov (United States)

    Yan, Zijun; Chen, Jincan

    1994-12-01

    The optimal performance of the solar-driven heat pump system consisting of a solar collector and a three-heat-source heat pump is studied, based on the linear heat-loss model of solar collectors and the general optimum relation of endoreversible three-heat-source heat pumps. The overall coefficient of performance of the system is adopted to be an objective function. The optimum operating temperature of the solar collector and the maximum overall coefficient of performance and maximum rate of heat pumping of the system are found. The results obtained here have more realistic meaning than those of classical thermodynamics for the optimal design and operation of practical solar-driven heat pump systems. Moreover, it is proven that it is not economic to use a solar-driven heat pump under certain circumstances. Finally, it is expounded that for a solar-driven heat pump system, the product of the efficiency of the solar collector and the coefficient of performance of the three-heat-source heat pump at maximum rate of heat pumping may not be used to calculate the optimal operating temperature of the solar collector and determine the optimal performance of the system.

  11. The Submersible Threat to Maritime Homeland Security

    Science.gov (United States)

    2013-09-01

    research would be how the HSE could possibly utilize small submersibles to enhance HS through such activities as using remotely operated subs to conduct...1 C. RESEARCH QUESTION AND METHODOLOGY ...................................4 D. SIGNIFICANCE TO THE FIELD...Technology ...................................................66 C. RECOMMENDATIONS FOR FUTURE RESEARCH .............................68 D. CONCLUSION

  12. Spin pumping in electrodynamically coupled magnon-photon systems

    Science.gov (United States)

    Bai, Lihui

    The electronics industry is quickly approaching the limitation of Moore's Law due to Joule heating in high density-integrated devices. To achieve new higher-speed devices and reduce energy consumption, researchers are turning to spintronics where the intrinsic spin, rather than the charge of electrons, is used to carry information in devices. Advances in spintronics have led to the discovery of giant magnetoresistance (GMR), spin transfer torque etc. Another subject, cavity electrodynamics, promises a completely new quantum algorithm by studying the properties of a single electron interacting with photons inside of a cavity. By merging both spintronics and cavity electrodynamics, a new cutting edge field called Cavity Spintronics is forming, which draws on the advantages of both subjects to develop new spintronics devices utilizing light-matter interaction. In this work, we use electrical detection, in combination with microwave transmission, to investigate both resonant and nonresonant magnon-photon coupling in a microwave cavity at room temperature. Spin pumping in a dynamically coupled magnon-photon system is found to be distinctly different from previous experiments. Characteristic coupling features such as modes anticrossing, linewidth evolution, peculiar line shape, and resonance broadening are systematically measured and consistently analyzed by a theoretical model set on the foundation of classical electrodynamic coupling. Our experimental and theoretical approach paves the way for pursuing microwave coherent manipulation of pure spin current via the combination of spin pumping and magnon-photon coupling. Co-authored with M. Harder, C.-M. Hu from University of Manitoba, Y. P. Chen, J. Q. Xiao from University of Delaware, and X. Fan from Univeristy of Denver.

  13. Sucker rod string design of the pumping systems

    Directory of Open Access Journals (Sweden)

    Chun Hua Liu

    2015-05-01

    Full Text Available The existing design of sucker rod string mainly focuses on the simplifying assumptions that rod string was exposed to simple tension loading. And its goal was to have equal modified stress at the top of each taper. The improved rod design was to have the same degree of safety at each section, and it used a dynamic force distribution that was proportional along the whole string. However, the available procedures did not provide the desired accuracy of its pertinent analysis, and the operators could not identify the specific phenomena that occur in CBM wells. In this paper, the mathematical models of rod loads and string length were developed based on the cyclic nature of rod string loading; the fatigue endurance method is used to design the single rod string; and the tapered rod string is designed to have an equal equivalent stress at the top of each section. Its application characteristics are demonstrated by the example of CBM wells in Ordos Basin. The interpretations of results show that the previous design gave the single rods a larger diameter and the top rods in the string a greater percent than the proposed method. The calculation should concern about inertial, vibration and friction forces to illustrate the elastic force waves travelling in the rod material with the speed of sound. The single string should be designed using fatigue endurance ratings due to asymmetric pulsating tension of rod loading; and the tapered string should involve a balanced design by setting the fatigue endurance at each section equal. A shorter stroke length gives a greater rod taper percentage and an increased load capacity results to an enhanced rod diameter. The rod diameter increases with the pump size and load capacity for the single string, and the rod taper percentage of the top rod strings increases with plunger diameter for the tapered string. The proposed research improves efficiency of the pumping system, assures good operating conditions, and reduces

  14. Sucker rod string design of the pumping systems

    Directory of Open Access Journals (Sweden)

    Chun Hua Liu

    2015-08-01

    Full Text Available The existing design of sucker rod string mainly focuses on the simplifying assumptions that rod string was exposed to simple tension loading. And its goal was to have equal modified stress at the top of each taper. The improved rod design was to have the same degree of safety at each section, and it used a dynamic force distribution that was proportional along the whole string. However, the available procedures did not provide the desired accuracy of its pertinent analysis, and the operators could not identify the specific phenomena that occur in CBM wells. In this paper, the mathematical models of rod loads and string length were developed based on the cyclic nature of rod string loading; the fatigue endurance method is used to design the single rod string; and the tapered rod string is designed to have an equal equivalent stress at the top of each section. Its application characteristics are demonstrated by the example of CBM wells in Ordos Basin. The interpretations of results show that the previous design gave the single rods a larger diameter and the top rods in the string a greater percent than the proposed method. The calculation should concern about inertial, vibration and friction forces to illustrate the elastic force waves travelling in the rod material with the speed of sound. The single string should be designed using fatigue endurance ratings due to asymmetric pulsating tension of rod loading; and the tapered string should involve a balanced design by setting the fatigue endurance at each section equal. A shorter stroke length gives a greater rod taper percentage and an increased load capacity results to an enhanced rod diameter. The rod diameter increases with the pump size and load capacity for the single string, and the rod taper percentage of the top rod strings increases with plunger diameter for the tapered string. The proposed research improves efficiency of the pumping system, assures good operating conditions, and reduces

  15. System Design Description Salt Well Liquid Pumping Dynamic Simulation

    Energy Technology Data Exchange (ETDEWEB)

    HARMSEN, R.W.

    1999-12-14

    The Salt Well Liquid (SWL) Pumping Dynamic Simulation used by the single-shell tank (SST) Interim Stabilization Project is described. A graphical dynamic simulation predicts SWL removal from 29 SSTs using an exponential function and unique time constant for each SST. Increasing quarterly efficiencies are applied to adjust the pumping rates during fiscal year 2000.

  16. Performance assessment of a direct-coupled PV water pumping system

    Science.gov (United States)

    Balaj, Ciprian I.; Man, Teodor E.; Paulescu, Marius

    2017-01-01

    Results of an experimental and numerical study on a water pumping system are presented in this paper. In this experiment a direct-coupled photovoltaic water pumping system, operating in real meteorological conditions, was fully monitored on the Solar Platform of the West University of Timisoara. Based on data recorded in this experiment, a numerical model for estimating the pumped water flow rate with respect to the incoming solar irradiance was developed. The model performance in relation with the solar radiative regime is assessed. The results show that that the numerical model tracks with high accuracy the measurement of daily volume of the pumped water, regardless the stability of the solar radiative regime.

  17. Thermal and economic assessment of ground-coupled storage for residential solar heat pump systems

    Science.gov (United States)

    Choi, M. K.; Morehouse, J. H.

    1980-11-01

    This study performed an analysis of ground-coupled stand-alone and series configured solar-assisted liquid-to-air heat pump systems for residences. The year-round thermal performance of these systems for space heating, space cooling, and water heating were determined by simulation and compared against non-ground-coupled solar heat pump systems as well as conventional heating and cooling systems in three geographic locations: Washington, D.C., Fort Worth, Tex., and Madison, Wis. The results indicate that without tax credits a combined solar/ground-coupled heat pump system for space heating and cooling is not cost competitive with conventional systems. Its thermal performance is considerably better than non-ground-coupled solar heat pumps in Forth Worth. Though the ground-coupled stand-alone heat pump provides 51% of the heating and cooling load with non-purchased energy in Forth Worth, its thermal performance in Washington and Madison is poor.

  18. AUTOMATIC CONTROL SYSTEM OF HEAT PUMP STATION GAS COOLER AT THE WIDE RANGE OF HEAT LOAD

    Directory of Open Access Journals (Sweden)

    Juravleov A.A.

    2008-08-01

    Full Text Available There is examined the structure the of control system of gas cooler of heat pump station, which uses the carbon dioxide as the working fluid in the transctitical thermodynamical cycle. It is analiyed the structure of the complex: heat pump station – district heating system.

  19. Generalized Performance Characteristics of Refrigeration and Heat Pump Systems

    Directory of Open Access Journals (Sweden)

    Mahmoud Huleihil

    2010-01-01

    Full Text Available A finite-time generic model to describe the behavior of real refrigeration systems is discussed. The model accounts for finite heat transfer rates, heat leaks, and friction as different sources of dissipation. The performance characteristics are cast in terms of cooling rate (r versus coefficient of performance (w. For comparison purposes, various types of refrigeration/heat pump systems are considered: the thermoelectric refrigerator, the reverse Brayton cycle, and the reverse Rankine cycle. Although the dissipation mechanisms are different (e.g., heat leak and Joule heating in the thermoelectric refrigerator, isentropic losses in the reverse Brayton cycle, and limits arising from the equation of state in the reverse Rankine cycle, the r−w characteristic curves have a general loop shape. There are four limiting types of operation: open circuit in which both r and w vanish in the limit of slow operation; short circuit in which again r and w vanish but in the limit of fast operation; maximum r; maximum w. The behavior of the considered systems is explained by means of the proposed model. The derived formulae could be used for a quick estimation of w and the temperatures of the working fluid at the hot and cold sides.

  20. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  1. Feasibility in photovoltaic pumping systems; Fiabilidad en sistemas de bombeo fotovoltaico

    Energy Technology Data Exchange (ETDEWEB)

    Narvarte, I.; Poza, F.; Lorenzo, E.

    2004-07-01

    In spite of the high reliability of PV pumping technology, PV pumping programs show that there are numerous problems when the whole system is evaluated: pumping, storage and distribution. Therefore, reality suggests the convenience of implementing quality assurance procedures taking into account the whole water chain. This paper presents how a current PV program in the Maghreb has faced up this challenge by elaborating technical specifications, carrying out quality tests, and developing testing procedures and facilities locally reproducible. (Author)

  2. Commercialization of PV-powered pumping systems for use in utility PV service programs. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The project described in this report was a commercialization effort focused on cost-effective remote water pumping systems for use in utility-based photovoltaic (PV) service programs. The project combined a commercialization strategy tailored specifically for electric utilities with the development of a PV-powered pumping system that operates conventional ac pumps rather than relying on the more expensive and less reliable PV pumps on the market. By combining these two attributes, a project goal was established of creating sustained utility purchases of 250 PV-powered water pumping systems per year. The results of each of these tasks are presented in two parts contained in this Final Summary Report. The first part summarizes the results of the Photovoltaic Services Network (PSN) as a new business venture, while the second part summarizes the results of the Golden Photon system installations. Specifically, results and photographs from each of the system installations are presented in this latter part.

  3. Analysis Mathlab / Simulink of a PV System Used for Water Pumping

    Directory of Open Access Journals (Sweden)

    BOUSSAIBO Andre

    2015-05-01

    Full Text Available The paper analyzes used a photovoltaic system used for pumping water. The particularity of the system is to store water in a tank so it does not require energy storage elecrtic produced by photovoltaic conversion. Maximum power transfer from source (photovoltaic systems the consumer requires the establishment maximum operating point in the characteristic power - voltage. The influence of various parameters on water pumping system operation is done using numerical simulation method. The whole system is simulated numerically in programming environment MATLAB/ SIMULINK. The implementation of numerical model of a system of solar pumping is important to optimally solve the problem of accumulation of water management in rural areas.

  4. Design development and testing of a solar PV pump based drip system for orchards

    Energy Technology Data Exchange (ETDEWEB)

    Pande, P.C.; Singh, A.K.; Ansari, S.; Vyas, S.K.; Dave, B.K. [Central Arid Zone Research Inst., Jodhpur (India)

    2003-03-01

    A Solar Photovoltaic (PV) pump operated drip irrigation system has been designed and developed for growing orchards in arid region considering different design parameters like pumps size, water requirements, the diurnal variation in the pressure of the pump due to change in irradiance and pressure compensation in the drippers. The system comprising a PV pump with 900 W{sub p} PV array and 800 W dc motor-pump mono-block, microfilter, main and sub-mains and three open-able low-pressure compensating drippers on each plant was field tested. The emission uniformity was observed to be 92-94% with discharge of 3.8 l/h in the pressure range of 70-100 kPa provided by the pump and thus the system could irrigate some 1 ha area within 2 h. Based on the performance of the PV pump and the drip system, it was inferred that about 5 ha area of orchard could be covered. The projected benefit-cost ratio for growing pomegranate orchards with such a system was evaluated to be above 2 even with the costly PV pump and therefore the system was considered to be an appropriate technology for the development of arid region. (Author)

  5. Multiphysics Modeling of an Annular Linear Induction Pump With Applications to Space Nuclear Power Systems

    Science.gov (United States)

    Kilbane, J.; Polzin, K. A.

    2014-01-01

    An annular linear induction pump (ALIP) that could be used for circulating liquid-metal coolant in a fission surface power reactor system is modeled in the present work using the computational COMSOL Multiphysics package. The pump is modeled using a two-dimensional, axisymmetric geometry and solved under conditions similar to those used during experimental pump testing. Real, nonlinear, temperature-dependent material properties can be incorporated into the model for both the electrically-conducting working fluid in the pump (NaK-78) and structural components of the pump. The intricate three-phase coil configuration of the pump is implemented in the model to produce an axially-traveling magnetic wave that is qualitatively similar to the measured magnetic wave. The model qualitatively captures the expected feature of a peak in efficiency as a function of flow rate.

  6. Absorption heat pumps in heating and cooling systems. Absorptiolaempoepumppu rakennusten laemmitys- ja jaeaehdytysjaerjestelmaessae

    Energy Technology Data Exchange (ETDEWEB)

    Aittomaeki, A.; Vaelimaeki, A.; Koepsi, M.

    1989-01-01

    The application of an absorption heat pumps as the heating and cooling system of an office building has been studied by means of a simulation model, designed for this application purpose. The effects of an absorption heat pump on emissions that are harmful to the environment depend on the fuel used. If the fuel is lightweight oil or gas, the sulphur and particle emissions diminish, but NO[sub x] and hydrocarbon emissions may increase as the combustion units become smaller. The use of an absorption heat pump reduces CFC emissions because other refrigerants are used in an absorption heat pump.

  7. Absorption heat pumps in heating and cooling systems; Absorptiolaempoepumppu rakennusten laemmitys- ja jaeaehdytysjaerjestelmaessae

    Energy Technology Data Exchange (ETDEWEB)

    Aittomaeki, A.; Vaelimaeki, A.; Koepsi, M.

    1989-12-31

    The application of an absorption heat pumps as the heating and cooling system of an office building has been studied by means of a simulation model, designed for this application purpose. The effects of an absorption heat pump on emissions that are harmful to the environment depend on the fuel used. If the fuel is lightweight oil or gas, the sulphur and particle emissions diminish, but NO{sub x} and hydrocarbon emissions may increase as the combustion units become smaller. The use of an absorption heat pump reduces CFC emissions because other refrigerants are used in an absorption heat pump.

  8. Review of solar assisted heat pump drying systems for agricultural and marine products

    Energy Technology Data Exchange (ETDEWEB)

    Daghigh, Ronak [Solar Energy Research Institute, Universiti Kebangsaan Malaysia (UKM), 43600, Bangi, Selangor (Malaysia); Department of Mechanical and Materials Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia (UKM), 43600, Bangi, Selangor (Malaysia); Ruslan, Mohd Hafidz; Sulaiman, Mohamad Yusof; Sopian, Kamaruzzaman [Solar Energy Research Institute, Universiti Kebangsaan Malaysia (UKM), 43600, Bangi, Selangor (Malaysia)

    2010-12-15

    Combining solar energy and heat pump technology is a very attractive concept. It is able to eliminate some difficulties and disadvantages of using solar dryer systems or solely using heat pump drying separately. Solar assisted heat pump drying systems have been studied and applied since the last decades in order to increase the quality of products where low temperature and well-controlled drying conditions are needed. This paper reviewed studies on the advances in solar heat pump drying systems. Results and observation from the studies of solar assisted heat pump dryer systems indicated that for heat sensitive materials; improved quality control, reduced energy consumption, high coefficient of performance and high thermal efficiency of the dryer were achieved. The way forward and future directions in R and D in this field are further research regarding theoretical and experimental analysis as well as for the replacement of conventional solar dryer or heat pump dryer with solar assisted heat pump drying systems and solar assisted chemical and ground source heat pump dryers which should present energy efficient applications of the technologies. (author)

  9. Application of heterogeneous blading systems is the way for improving efficiency of centrifugal energy pumps

    Science.gov (United States)

    Pochylý, F.; Haluza, M.; Fialová, S.; Dobšáková, L.; Volkov, A. V.; Parygin, A. G.; Naumov, A. V.; Vikhlyantsev, A. A.; Druzhinin, A. A.

    2017-11-01

    The results of independent research implemented by the teams of authors representing the Brno University of technology (Czech Republic) and Moscow Power Engineering Institute National Research University (Russia) are presented and compared. The possibilities for improving the energy efficiency of slow-speed centrifugal pumps (with a specific speed coefficient n s chemical industries too. The research was focused on achieving the shape of the pump efficiency characteristics providing a significant extension of its effective working zone and increasing its integrated efficiency. The results were obtained based on new approaches to the formation of a blading system of an impeller of a slow-speed centrifugal pump different from the traditional blading system. The analytical dependences illustrating the influence of individual geometry of a blading system on the efficiency were presented. The possibilities of purposeful changing of its structure were demonstrated. It was experimentally confirmed that use of the innovative blading system makes it possible to increase the pump efficiency by 1-4% (in the experiments for the pumps with n s = 33 and 55) and to extend its efficient working zone approximately by 15-20% (in the experiment for the pumps with n s = 33 and 66). The latter is especially important for the supply pumps of NPP power units. The experimental results for all investigated pumps are presented in comparison with the characteristics of the efficiency provided by the blading systems designed by traditional methods.

  10. Modeling and Optimization of a CoolingTower-Assisted Heat Pump System

    National Research Council Canada - National Science Library

    Xiaoqing Wei; Nianping Li; Jinqing Peng; Jianlin Cheng; Jinhua Hu; Meng Wang

    2017-01-01

    To minimize the total energy consumption of a cooling tower-assisted heat pump (CTAHP) system in cooling mode, a model-based control strategy with hybrid optimization algorithm for the system is presented in this paper...

  11. Estimation of the characteristic curves of pumped systems working as turbines through their curves operating as pump

    Directory of Open Access Journals (Sweden)

    L. Romero-Marrero

    2018-01-01

    Full Text Available The current research presents a methodology to select pump working as turbines (PAT in recovery system in water distribution networks using their pump characteristic curve. The methodology is based on the review of the empirical methods that are currently proposed and enables the empiric estimation the operating point of the energy converter. The methodology determines the analysis of the operation point (flow, recovered head and efficiency both constant and variable flows over time. When the flow changes, the methodology uses experiments curves that are based on characteristic parameters (discharge and head number. This proposal was applied on case study that is located in Callosa d’en Sarrià (Alicante. In the analyzed case, the recovered energy was 76884.71 kWh/year, representing 74.2% of the current energy that is dissipated by the pressure reduction valve.

  12. Optimal Power Consumption in a Central Heating System with Geothermal Heat Pump

    DEFF Research Database (Denmark)

    Tahersima, Fatemeh; Stoustrup, Jakob; Rasmussen, Henrik

    2011-01-01

    Driving a ground source heat pump in a central heating system with the minimum power consumption is studied. The idea of control is based on the fact that, in a heat pump, the temperature of the forward water has a strong positive correlation with the consumed electric power by the compressor. Th...

  13. Life cycle assessment of domestic heat pump hot water systems in Australia

    Directory of Open Access Journals (Sweden)

    Moore Andrew D.

    2017-01-01

    Full Text Available Water heating accounts for 23% of residential energy consumption in Australia, and, as over half is provided by electric water heaters, is a significant source of greenhouse gas emissions. Due to inclusion in rebate schemes heat pump water heating systems are becoming increasingly popular, but do they result in lower greenhouse gas emissions? This study follows on from a previous life cycle assessment study of domestic hot water systems to include heat pump systems. The streamlined life cycle assessment approach used focused on the use phase of the life cycle, which was found in the previous study to be where the majority of global warming potential (GWP impacts occurred. Data was collected from an Australian heat pump manufacturer and was modelled assuming installation within Australian climate zone 3 (AS/NZS 4234:2011. Several scenarios were investigated for the heat pumps including different sources of electricity (grid, photovoltaic solar modules, and batteries and the use of solar thermal panels. It was found that due to their higher efficiency heat pump hot water systems can result in significantly lower GWP than electric storage hot water systems. Further, solar thermal heat pump systems can have lower GWP than solar electric hot water systems that use conventional electric boosting. Additionally, the contributions of HFC refrigerants to GWP can be significant so the use of alternative refrigerants is recommended. Heat pumps combined with PV and battery technology can achieve the lowest GWP of all domestic hot water systems.

  14. Exergy analysis of the performance of low-temperature district heating system with geothermal heat pump

    Science.gov (United States)

    Sekret, Robert; Nitkiewicz, Anna

    2014-03-01

    Exergy analysis of low temperature geothermal heat plant with compressor and absorption heat pump was carried out. In these two concepts heat pumps are using geothermal water at 19.5 oC with spontaneous outflow 24 m3/h as a heat source. The research compares exergy efficiency and exergy destruction of considered systems and its components as well. For the purpose of analysis, the heating system was divided into five components: geothermal heat exchanger, heat pump, heat distribution, heat exchanger and electricity production and transportation. For considered systems the primary exergy consumption from renewable and non-renewable sources was estimated. The analysis was carried out for heat network temperature at 50/40 oC, and the quality regulation was assumed. The results of exergy analysis of the system with electrical and absorption heat pump show that exergy destruction during the whole heating season is lower for the system with electrical heat pump. The exergy efficiencies of total system are 12.8% and 11.2% for the system with electrical heat pump and absorption heat pump, respectively.

  15. Nutrient pumping by submesoscale circulations in the mauritanian upwelling system

    Science.gov (United States)

    Hosegood, P. J.; Nightingale, P. D.; Rees, A. P.; Widdicombe, C. E.; Woodward, E. M. S.; Clark, D. R.; Torres, R. J.

    2017-12-01

    Observations made within a cold filament in the Mauritanian upwelling system demonstrate that intense submesoscale circulations at the peripheral edges of the filament are likely responsible for anomalously high levels of observed primary productivity by resupplying nutrients to the euphotic zone. Measurements made on the shelf within the recently upwelled water reveal that primary production (PP) of 8.2 gC/m-2 day-1 was supported by nitrate concentrations (NC) of 8 mmol m-3. Towards the front that defined the edge of the filament containing the upwelled water as it was transported offshore, PP dropped to 1.6 gC m-2 day-1 whilst NC dropped to 5.5 mmol m-3. Thus, whilst the observed nutrients on the shelf accounted for 90% of new production, this value dropped to ∼60% near the filament's front after accounting for vertical turbulent fluxes and Ekman pumping. We demonstrate that the N15 was likely to have been supplied at the front by submesoscale circulations that were directly measured as intense vertical velocities ⩾100 m day-1 by a drifting acoustic Doppler current profiler that crossed a submesoscale surface temperature front. At the same time, a recently released tracer was subducted out of the mixed layer within 24 h of release, providing direct evidence that the frontal circulations were capable of accessing the reservoir of nutrients beneath the pycnocline. The susceptibility of the filament edge to submesoscale instabilities was demonstrated by O(1) Rossby numbers at horizontal scales of 1-10 km. The frontal circulations are consistent with instabilities arising from a wind-driven nonlinear Ekman buoyancy flux generated by the persistent northerly wind stress that has a down-front component at the northern edge of the inshore section of the filament. The prevalence of submesoscale instabilities and their associated vertical circulations are proposed to be a key mechanism operating at sub-grid scales and sustaining new production throughout the upwelling

  16. Selection of Sampling Pumps Used for Groundwater Monitoring at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Schalla, Ronald; Webber, William D.; Smith, Ronald M.

    2001-11-05

    The variable frequency drive centrifugal submersible pump, Redi-Flo2a made by Grundfosa, was selected for universal application for Hanford Site groundwater monitoring. Specifications for the selected pump and five other pumps were evaluated against current and future Hanford groundwater monitoring performance requirements, and the Redi-Flo2 was selected as the most versatile and applicable for the range of monitoring conditions. The Redi-Flo2 pump distinguished itself from the other pumps considered because of its wide range in output flow rate and its comparatively moderate maintenance and low capital costs. The Redi-Flo2 pump is able to purge a well at a high flow rate and then supply water for sampling at a low flow rate. Groundwater sampling using a low-volume-purging technique (e.g., low flow, minimal purge, no purge, or micropurgea) is planned in the future, eliminating the need for the pump to supply a high-output flow rate. Under those conditions, the Well Wizard bladder pump, manufactured by QED Environmental Systems, Inc., may be the preferred pump because of the lower capital cost.

  17. Experimental Design and Analysis of Pump as Turbine for Microhydro System

    Science.gov (United States)

    Ismail, M. A.; Muzammil, W. K.; Rahman, M.; Ibrahim, M. W. K.; Misran, S.

    2017-07-01

    Pump as Turbine (PAT) is typically used as electromechanical components in microhydro systems, especially by rural communities in developing countries to reduce initial capital cost. The technology is readily available and easily accessible compared to commercially available turbines. The aim of this paper is to present the experimental design and analysis of PAT for microhydro systems over a range of rotational speeds. An end suction centrifugal pump was tested by inversing the flow across the pump. The rotational speed of the impeller was controlled by manipulating the braking force applied to the output shaft. The corresponding flow rate, pressure, and torque were recorded and presented. The experiment results show that the centrifugal pump can operate in turbine modes without any modification on mechanical components with the highest efficiency of 65.04%; however, at off-design operation, the efficiency decreases significantly due to unmatched flow velocity with the wall boundaries inside the pump.

  18. Syringe-pump-induced fluctuation in all-aqueous microfluidic system implications for flow rate accuracy.

    Science.gov (United States)

    Li, Zida; Mak, Sze Yi; Sauret, Alban; Shum, Ho Cheung

    2014-02-21

    We report a new method to display the minute fluctuations induced by syringe pumps on microfluidic flows by using a liquid-liquid system with an ultralow interfacial tension. We demonstrate that the stepper motor inside the pump is a source of fluctuations in microfluidic flows by comparing the frequencies of the ripples observed at the interface to that of the pulsation of the stepper motor. We also quantify the fluctuations induced at different flow rates, using syringes of different diameters, and using different syringe pumps with different advancing distances per step. Our work provides a way to predict the frequency of the fluctuation that the driving syringe pump induces on a microfluidic system and suggests that syringe pumps can be a source of fluctuations in microfluidic flows, thus contributing to the polydispersity of the resulting droplets.

  19. Performance analysis of air source heat pump system for office building

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dong Won; KIm, Yong Chan [Korea University, Seoul (Korea, Republic of); Chang, Young Soo [School of Mechanical System Engineering, Kookmin University, Seoul (Korea, Republic of)

    2016-11-15

    In this study, the performance of an air source heat pump system installed in a commercial building is analyzed using the developed heat pump performance model and building load simulation data of several regions in Korea. The performance test of an air source heat pump system with a variable speed compressor is tested to develop model that considers changes in the performance characteristics of the heat pump system under various operating conditions. The heat pump system is installed in an environmental chamber, and the experimental equipment is set up according to the manufacturer' specifications as well as the AHRI 1230 test specifications. The performance test conditions of the heat pump system are selected using a central composite design method, in which 29 points for each cooling and heating mode are selected. The developed performance model based on experimental data predicts experimental values with an error of ±5 %. Building cooling and heating loads in three regions in Korea are analyzed using TRNSYS software, which includes standard building and weather data from Seoul, Daejeon and Busan in Korea. The effects of outdoor air temperature and part load ratio on the performance and regional monthly average power consumption of the heat pump system are analyzed.

  20. Generic Guide Specification for Geothermal Heat Pump Systems

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, WKT

    2000-04-12

    The attached Geothermal (Ground-Source) Heat Pump (GHP) Guide Specifications have been developed by Oak Ridge National Laboratory (ORNL) with the intent to assist federal agency sites and engineers in the preparation of construction specifications for GHP projects. These specifications have been developed in the industry-standard Construction Specification Institute (CSI) format and cover several of the most popular members of the family of GHP systems. These guide specifications are applicable to projects whether the financing is with conventional appropriations, arranged by GHP specialty ESCOs under the U.S. Department of Energy's Technology-Specific GHP Super ESPCs, arranged by utilities under Utility Energy Service Contracts (UESCs) or arranged by generalist ESCOs under the various regional ESPCs. These specifications can provide several benefits to the end user that will help ensure successful GHP system installations. GHP guide specifications will help to streamline the specification development, review, and approval process because the architecture and engineering (AE) firm will be working from the familiar CSI format instead of developing the specifications from other sources. The guide specifications help to provide uniformity, standardization, and consistency in both the construction specifications and system installations across multiple federal sites. This standardization can provide future benefits to the federal sites in respect to both maintenance and operations. GHP guide specifications can help to ensure that the agency is getting its money's worth from the GHP system by preventing the use of marginal or inferior components and equipment. The agency and its AE do not have to start from scratch when developing specifications and can use the specification as a template and/or a checklist in developing both the design and the contract documents. The guide specifications can save project costs by reducing the engineering effort required

  1. Improving the Efficiency of the Heat Pump Control System of Carbon Dioxide Heat Pump with Several Evaporators and Gas Coolers

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2016-12-01

    Full Text Available The problem of coordination of the values of the refrigerant flow through the evaporators and gas coolers of the heat pump for the simultaneous production of heat and cold is studied. The compensation of the variations of the total flow through the evaporators is implemented using the variation of the capacity of the compressor and a corresponding change in flow through the auxiliary gas cooler of the heat pump. Control system of this gas cooler is constructed using the invariance principle of the output value (outlet temperature of the heated agent with respect to perturbations on the control channel (the refrigerant flow through the gas cooler. Principle of dual-channel compensation of the disturbance and advancing signal on input of control valve of the refrigerant through the gas cooler is ensured. Due to proposed solution, the intensity of the disturbances on the flow of refrigerant is reduced. Due to proposed technical solution power consumed by the heat pump compressor drive under transients is decreased.

  2. Submersion Quenching of Undercooled Liquid Metals in an Electrostatic Levitator

    Science.gov (United States)

    SanSoucie, Michael P.; Rogers, Jan R.

    2016-01-01

    The NASA Marshall Space Flight Center (MSFC) electrostatic levitation (ESL) laboratory has a long history of providing materials research and thermophysical property data. The laboratory has recently added a new capability, a rapid quench system. This system allows samples to be dropped into a quench vessel that can be filled with a low melting point material, such as a gallium or indium alloy. Thereby allowing rapid quenching of undercooled liquid metals and alloys. This is the first submersion quench system inside an electrostatic levitator. The system has been tested successfully with samples of zirconium, iron-cobalt alloys, titanium-zirconium-nickel alloys, and silicon-cobalt alloys. This rapid quench system will allow materials science studies of undercooled materials and new materials development, including studies of metastable phases and transient microstructures. In this presentation, the system is described and some initial results are presented.

  3. Variable speed pumped storage system fed by large-scale cycloconverter

    Energy Technology Data Exchange (ETDEWEB)

    T, Taguchi. (The Tokyo Electric Power Co. Inc., Tokyo (Japan)); Mukai, K.; Yanagisawa, T.; Kanai, T. (Toshiba Corp., Tokyo (Japan))

    1992-01-01

    The world{prime}s first variable speed pumped storage system fed by large-scale cycloconverter was brought into operation at the Yagisawa power station Unit 2 of Tokyo Electric Power Co. in December, 1990. The present paper introduces an outline and operation results of this system. This remarkable system incorporates the latest large-scale, large-capacity power electronics technology, ultrahigh-speed digital control technology, and large-scale, large-capacity generator-motor technology. From the actual machine tests conducted at the Yagisawa power station, various functions of the variable speed pumped storage system were verified. The variable speed system enabled to regulate the input of the pump within the range of about 50 to 85MW. Additionally, in the turbine operation, vibration of the pump-turbine was improved by operating with the optimum rotating speed. Furthermore, the variable speed system did not cause unstable condition of power swing. 4 refs., 16 figs., 2 tabs.

  4. Assessment of solar-assisted gas-fired heat pump systems

    Science.gov (United States)

    Lansing, F. L.

    1981-01-01

    As a possible application for the Goldstone Energy Project, the performance of a 10 ton heat pump unit using a hybrid solar gas energy source was evaluated in an effort to optimize the solar collector size. The heat pump system is designed to provide all the cooling and/or heating requirements of a selected office building. The system performance is to be augmented in the heating mode by utilizing the waste heat from the power cycle. A simplified system analysis is described to assess and compute interrrelationships of the engine, heat pump, and solar and building performance parameters, and to optimize the solar concentrator/building area ratio for a minimum total system cost. In addition, four alternative heating cooling systems, commonly used for building comfort, are described; their costs are compared, and are found to be less competitive with the gas solar heat pump system at the projected solar equipment costs.

  5. Experimental evaluation of mechanical heart support system based on viscous friction disc pump

    Directory of Open Access Journals (Sweden)

    A. M. Chernyavskiy

    2017-01-01

    Full Text Available Aim. Experimental evaluation of the viscous friction disk pump efficiency, studying the relationship between inter-disk clearance and sizes of input and output ports and pump performance parameters.Materials and methods. To assess the characteristics and to optimize the disk friction pump design the pump model and experimental stand were created. Pump dimensions were set on the basis of medical and biological requirements for mechanical heart support systems and with due consideration of the experimental studies of our colleagues from Pennsylvania. Flow volume of the working fluid was measured by float rotameter Krohne VA-40 with measurement error of not more than 1%. The pressure values in the hydrodynamic circuit were measured using a monitor manufactured by Biosoft-M. Expansion device allowed changing the flow resistance of the system simulating the total peripheral resistance of the circulatory system.Results. Linear direct correlation between the pump performance and the pressure drop of liquid being created at the inlet and outlet of the pump was obtained. The required flow rate (5–7 l/min and pressure (90–100 mmHg were reached when the rotor speed was in the range of 2500–3000 rev/min. It has been shown that the increase of the inlet diameter to 15 mm has not resulted in a significant increase in the pump performance, and that the highest efficiency values can be obtained for the magnitude of inter-disk gap of 0.4–0.5 mm.Conclusion. Designed and manufactured experimental disc pump model for pumping fluid has showed the fundamental possibility to use this model as a system for mechanical support of the heart.

  6. A low cost wireless data acquisition system for a remote photovoltaic (PV) water pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Mahjoubi, A.; Mechlouch, R. F.; Brahim, A. B. [National School of Engineering of Gabes, Gabes University, Chemical and Processes Engineering Department, Gabes (Tunisia)

    2011-07-01

    This paper presents the design and development of a 16F877 microcontroller-based wireless data acquisition system and a study of the feasibility of different existing methodologies linked to field data acquisition from remote photovoltaic (PV) water pumping systems. Various existing data transmission techniques were studied, especially satellite, radio, Global System for Mobile Communication (GSM) and General Packet Radio Service (GPRS). The system's hardware and software and an application to test its performance are described. The system will be used for reading, storing and analyzing information from several PV water pumping stations situated in remote areas in the arid region of the south of Tunisia. The remote communications are based on the GSM network and, in particular, on the Short text Message Service (SMS). With this integrated system, we can compile a complete database of the different parameters related to the PV water pumping systems of Tunisia. This data could be made available to interested parties over the Internet. (authors)

  7. A review on opportunities for the development of heat pump drying systems in South Africa

    Directory of Open Access Journals (Sweden)

    Thomas Kivevele

    2014-05-01

    Full Text Available Recently, it has been discovered that heat pump drying is an efficient method of drying for drying industries. Heat pumps deliver more heat during the drying process than the work input to the compressor. Heat pump drying is a more advanced method than the traditional South African industrial and agricultural drying methods, such as direct/indirect sunlight, wood burning, fossil fuel burning, electrical heating and diesel engine heating. Heat pump dryers provide high energy efficiency with controllable temperature, air flow and air humidity and have significant energy-saving potential. In the last decade the market for heat pump systems for water heating and space cooling/heating has grown in South Africa, but the development of heat pumps for industrial and agricultural drying is very slow. As a result of high increases in fossil fuel prices and electricity in South Africa, as well as the problem of CO2 emissions, green energy, energy saving and energy efficiency are imperative. The development of heat pump drying systems in South Africa is an efficient way to solve energy problems in drying applications as this technology is still in its infancy. We review studies on heat pump drying and compare the methods therein with the most common methods of drying in South Africa.

  8. A fuzzy controller for the VASPS (Vertical Annular Separation and Pumping System) subsea separation and pumping system; Um controlador fuzzy para o sistema de separacao e bombeamento submarino - VASP (Vertical Annular Separation and Pumping System)

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Alex F.; Mendes, Jose Ricardo P.; Morooka, Celso K. [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica. Dept. de Engenharia de Petroleo; Estevam, Valdir [PETROBRAS, Rio de Janeiro, RJ (Brazil); Guilherme, Ivan R. [UNESP, Rio Claro, SP (Brazil). Inst. de Geociencias e Ciencias Exatas. Dept. de Estatistica, Matematica Aplicada e Computacao; Rigo, Jose Eduardo [Centro Federal de Educacao Tecnologica no Espirito Santo (CEFETES), Vitoria, ES (Brazil)

    2004-07-01

    In this paper the designs of a fuzzy controller for the VASPS (Vertical Annular Separation and Pumping System) liquid level and separation pressure control are presented, as well as a simulation of its work to evaluate the performance of the controller designed. The VASPS is a two-phase subsea separation and pumping system, which is made up of a separation vessel, where the mixture (liquid and gas) enters and suffers the separation process through three levels, the expansion chamber, the helix and the pool. The liquid inside the pool is taken to the platform using a pump that with a choke control the pool liquid level. The pool liquid level control is necessary because if the level exceeds the maximum value allowed, the liquid can invade the space occupied by the helix and hinder the separation process. An the other hand if the level is below the minimum allowed the pump can be damaged. The separation pressure control is important for operational security and efficiency issues, because when we keep the separation pressure near an optimum value we are maximizing its efficiency. With the controller and the simulator, many simulations of the work of system were made to get results that could be used to evaluate if the designed controller solved the problem and if its performance were satisfactory. After, a PID control system was designed to be used as comparison with the results obtained with the fuzzy controller, since the PID is widely used in the industrial environment. (author)

  9. Counteracting ammonia inhibition during anaerobic digestion by recovery using submersible microbial desalination cell

    DEFF Research Database (Denmark)

    Zhang, Yifeng; Angelidaki, Irini

    2015-01-01

    Ammonia inhibition is one of the most frequent and serious problems in biogas plants. In this study, a novel hybrid system consisting of a submersible microbial desalination cell (SMDC) and a continuous stirred tank reactor (CSTR) was developed for counteracting ammonia inhibition during anaerobic...

  10. Influence of individual heat pumps on wind power integration – Energy system investments and operation

    DEFF Research Database (Denmark)

    Hedegaard, Karsten; Münster, Marie

    2013-01-01

    Individual heat pumps are expected to constitute a significant electricity demand in future energy systems. This demand becomes flexible if investing in complementing heat storage capabilities. In this study, we analyse how the heat pumps can influence the integration of wind power by applying...... an energy system model that optimises both investments and operation, and covers various heat storage options. The Danish energy system by 2030 with around 50–60% wind power is used as a case study. Results show that the heat pumps, even without flexible operation, can contribute significantly...... to facilitating larger wind power investments and reducing system costs, fuel consumption, and CO2 emissions. Investments in heat storages can provide only moderate system benefits in these respects. The main benefit of the flexible heat pump operation is a reduced need for peak/reserve capacity, which is also...

  11. A Low Cost Wireless Data Acquisition System for a Remote Photovoltaic (PV Water Pumping System

    Directory of Open Access Journals (Sweden)

    Ammar Mahjoubi

    2011-01-01

    Full Text Available This paper presents the design and development of a 16F877 microcontroller-based wireless data acquisition system and a study of the feasibility of different existing methodologies linked to field data acquisition from remote photovoltaic (PV water pumping systems. Various existing data transmission techniques were studied, especially satellite, radio, Global System for Mobile Communication (GSM and General Packet Radio Service (GPRS. The system’s hardware and software and an application to test its performance are described. The system will be used for reading, storing and analyzing information from several PV water pumping stations situated in remote areas in the arid region of the south of Tunisia. The remote communications are based on the GSM network and, in particular, on the Short text Message Service (SMS. With this integrated system, we can compile a complete database of the different parameters related to the PV water pumping systems of Tunisia. This data could be made available to interested parties over the Internet.

  12. Test results of a combined distributed ion pump/non-evaporable getter pump design developed as a proposed alternative pumping system for the PEP-II asymmetric B-Factory collider

    Energy Technology Data Exchange (ETDEWEB)

    Holdener, F.; Behne, D.; Hathaway, D. [Lawrence Livermore National Lab., CA (United States)] [and others

    1995-04-24

    The authors have built and tested an all-in-one combination plate-type distributed ion pump/non-evaporable getter pump design (DIP/NEG) considered as a proposed alternative pumping system for the PEP-II B-Factory High Energy Ring (HER). The DIP portion of the design used a Penning cell hole size of 12 mm in a mostly uniform magnetic field of 0.18 T. The NEG portion of the design used commercially available non-evaporable getter material type St-707{trademark}. A detailed description of the design is presented along with results of pumping speed measurements.

  13. Elimination of Oscillations in a Central Heating System using Pump Control

    DEFF Research Database (Denmark)

    Andersen, Palle; Pedersen, Tom Søndergaard; Stoustrup, Jakob

    2000-01-01

    In central heating systems with thermostatic valve temperature control it is a well known fact that room temperature oscillations may occur when the heat demand becomes low due to the non-linear behavior of the control loop. This is not only discomforting but it also increases the energy cost...... of heating the room. Using the pump speed as an active part in control is it shown that the room temperature may be stabilized in a wider interval of heat demand. The idea is to control the pump speed in a way that keeps the thermostatic valve within a suitable operating area using an estimate of the valve...... position. The position is estimated from the pump terminals, using the pump flow and the pump differential pressure. The concept is tested on a small central heating test bench. The results show that it is possible to stabilize the room temperature even at part load conditions...

  14. Designing & Optimizing a Moving Magnet Pump for Liquid Sodium Systems

    Science.gov (United States)

    Hvasta, Michael G.

    Advanced materials such as NF-616, NF-709, HT-UPS, and silicon carbide (SiC) have greater strength than traditional structural materials such as 316-SS. Thus, using these high-strength materials to build sodium-cooled fast reactors (SFRs) could potentially reduce construction costs by lessening the required amount of material, and increase the efficiency of electromagnetic pumps by limiting ohmic heating within the pump duct walls. However, information pertaining to the sodium-compatibility of these alloys and ceramics is very sparse. Therefore, two separate test facilities were built to study the impact of both static and dynamic sodium corrosion The dynamic test facility enabled sodium corrosion to be studied under prototypic SFR operating conditions (T = 500 [C], V = 9.35 [m/s], CO = 2-3 [wppm]). The oxygen concentration, CO, within the dynamic test facility was maintained using a cold trap and measured with a plugging meter. The flow rate of the sodium was measured using a calibrated electromagnetic flowmeter. A moving magnet pump (MMP) was used to move the liquid sodium past the corrosion samples at a high velocity. Using newly developed theory, it was found that MMP performance could be accurately modeled and predicted for a wide variety of pump configurations.

  15. Study on the System Design of a Solar Assisted Ground Heat Pump System Using Dynamic Simulation

    Directory of Open Access Journals (Sweden)

    Min Gyung Yu

    2016-04-01

    Full Text Available Recently, the use of hybrid systems using multiple heat sources in buildings to ensure a stable energy supply and improve the system performance has gained attention. Among them, a heat pump system using both solar and ground heat was developed and various system configurations have been introduced. However, establishing a suitable design method for the solar-assisted ground heat pump (SAGHP system including a thermal storage tank is complicated and there are few quantitative studies on the detailed system configurations. Therefore, this study developed three SAGHP system design methods considering the design factors focused on the thermal storage tank. Using dynamic energy simulation code (TRNSYS 17, individual performance analysis models were developed and long-term quantitative analysis was carried out to suggest optimum design and operation methods. As a result, it was found that SYSTEM 2 which is a hybrid system with heat storage tank for only a solar system showed the highest average heat source temperature of 14.81 °C, which is about 11 °C higher than minimum temperature in SYSTEM 3. Furthermore, the best coefficient of performance (COP values of heat pump and system were 5.23 and 4.32 in SYSYEM 2, using high and stable solar heat from a thermal storage tank. Moreover, this paper considered five different geographical and climatic locations and the SAGHP system worked efficiently in having high solar radiation and cool climate zones and the system COP was 4.51 in the case of Winnipeg (Canada where the highest heating demand is required.

  16. Analysis of Fuel Cell Driven Ground Source Heat Pump Systems in Community Buildings

    Directory of Open Access Journals (Sweden)

    Jong-Keun Shin

    2013-05-01

    Full Text Available In the present study, a fuel cell driven ground source heat pump (GSHP system is applied in a community building and heat pump system performance is analyzed by computational methods. Conduction heat transfer between the brine pipe and ground is analyzed by TEACH code in order to predict the performance of the heat pump system. The predicted coefficient of performance (COP of the heat pump system and the energy cost were compared with the variation of the location of the objective building, the water saturation rate of the soil, and the driven powers of the heat pump system. Compared to the late-night electricity driven system, a significant reduction of energy cost can be accomplished by employing the fuel cell driven heat pump system. This is due to the low cost of electricity production of the fuel cell system and to the application of the recovered waste heat generated during the electricity production process to the heating of the community building.

  17. Commercial Impact and Optimum Capacity Determination of Pumped Storage Hydro Plant for a Practical Power System

    Science.gov (United States)

    Latha, P. G.; Anand, S. R.; Imthias, Ahamed T. P.; Sreejith, P. S., Dr.

    2013-06-01

    This paper attempts to study the commercial impact of pumped storage hydro plant on the operation of a stressed power system. The paper further attempts to compute the optimum capacity of the pumped storage scheme that can be provided on commercial basis for a practical power system. Unlike the analysis of commercial aspects of pumped storage scheme attempted in several papers, this paper is presented from the point of view of power system management of a practical system considering the impact of the scheme on the economic operation of the system. A realistic case study is presented as the many factors that influence the pumped storage operation vary widely from one system to another. The suitability of pumped storage for the particular generation mix of a system is well explored in the paper. To substantiate the economic impact of pumped storage on the system, the problem is formulated as a short-term hydrothermal scheduling problem involving power purchase which optimizes the quantum of power to be scheduled and the duration of operation. The optimization model is formulated using an algebraic modeling language, AMPL, which is then solved using the advanced MILP solver CPLEX.

  18. Design of water pumping system by wind turbine for using in coastal areas of Bangladesh

    Science.gov (United States)

    Alam, Muhammad Mahbubul; Tasnim, Tamanna; Doha, Umnia

    2017-06-01

    In this work, a theoretical analysis has been carried out to analyze the prospect of Wind Pumping System (WPS) for using in coastal areas of Bangladesh. Wind speed data of three coastal areas of Bangladesh-Kutubdia, Patenga and Sathkhira has been analyzed and an optimal wind turbine viable for this wind speed range has been designed using the simulation software Q-blade. The simulated turbine is then coupled with a rotodynamic pump. The output of the Wind Pumping System (WPS) for the three coastal areas has been studied.

  19. MEMS based pumped liquid cooling systems for micro/nano spacecraft thermal control

    Science.gov (United States)

    Birur, G. C.; Shakkottai, P.; Sur, T. W

    2001-01-01

    The objective is to develop MEMS based pumped liquid cooling system for removing over 20 W/cm squared from high power density microelectronics and science payloads considered for future micro/nano sciencecraft.

  20. Solar-assisted heat pump system for cost-effective space heating and cooling

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J W; Kush, E A; Metz, P D

    1978-03-01

    The use of heat pumps for the utilization of solar energy is studied. Two requirements for a cost-effective system are identified: (1) a special heat pump whose coefficient of performance continues to rise with source temperature over the entire range appropriate for solar assist, and (2) a low-cost collection and storage subsystem able to supply solar energy to the heat pump efficiently at low temperatures. Programs leading to the development of these components are discussed. A solar assisted heat pump system using these components is simulated via a computer, and the results of the simulation are used as the basis for a cost comparison of the proposed system with other solar and conventional systems.

  1. Paraformaldehyde pellet not necessary in vacuum-pumped maple sap system

    Science.gov (United States)

    H. Clay Smith; Carter B. Gibbs

    1970-01-01

    In a study of sugar maple sap collection through a vacuum-pumped plastic tubing system, yields were compared between tapholes in which paraformaldehyde pellets were used and tapholes without pellets, Use of the pellets did not increase yield.

  2. Systems for apartment buildings heat pumps. Final report; System foer fastighetsvaermepumpar. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Aakervall, Daniel (WSP Environmental, Stockholm (Sweden)); Rogstam, Joergen; Grotherus, Maarten (Sveriges Energi- och Kylcentrum, Katrineholm (Sweden))

    2009-05-15

    A fast growing segment of the heat pump business is the apartment building applications. Historically the experience base related to such installations is limited. However, this application is more complex than the much more widely spread domestic applications. The core idea of the project was to generate and collect information to avoid mistakes and to encourage the heat pump technology. By interviewing the 'market' and compiling the information good recommendations has been achieved. It is of great importance to convey the best available recommendations to the installers on the market to avoid pit holes and highlight the opportunities for installers and end consumers. A website has been design and built, www.sfvp.se, which contains useful tools for installers and potential system customers. A number of calculation tools to estimate heat requirement, cost of different heating systems, primary energy need, LCC, etc. are all available. The core of the site is the database containing heat pump installations with related data of importance. The data available is such key data as performance figures, cost of installation, etc. Today 104 system installations are collected in the database and these are marked in a colour coding to indicate the quality of the input data. Installations verified with measurement are given higher significance. It has been an unexpected challenge to find documented systems, so one of the conclusions of the project is that there is a great need for further measurement on the field. More information should be directed to the customers to request such equipment when systems are installed. The database enables statistical analysis of the key figures and it can be seen that the average seasonal COP is 3.2 and there are small differences between exhaust air and ground source heat pumps. It should be emphasised that the number of installations do not give statistical confidence for all kinds of analysis yet. Field measurements in apartment

  3. Conductivity of strongly pumped superconductors. An electron-phonon system far from equilibrium

    Energy Technology Data Exchange (ETDEWEB)

    Krull, Holger

    2015-01-29

    The study of nonequilibrium physics is of great interest, because one can capture novel phenomena and properties which are hidden at equilibrium, e.g., one can study relaxation processes. A common way to study the nonequilibrium dynamics of a sample is a pump-probe experiment. In a pump probe experiment an intense laser pulse, the so called pump pulse, excites the sample and takes it out of equilibrium. After a certain delay time a second pulse, the probe pulse, measures the actual state of the sample. In this thesis, we theoretically study the pump-probe response of superconductors. On the one hand we are interest in the effect of a pump pulse and on the other hand we want to provide the pump-probe response, such that experimental measurement can be easily interpreted. In order to do this, we use the density matrix formalism to compute the pump-probe response of the system. In the density matrix formalism equations of motion are set up for expectation values of interest. In order to study the dynamics induced by a pump pulse, we compute the temporal evolution of the quasiparticle densities and the mean phonon amplitude. We find that the induced dynamics of the system depends on characteristics of the pump pulse. For short pulses, the system is pushed into the nonadiabatic regime. In this regime, the order parameter is lowered during the pump pulse and shows a 1/(√(t))-decaying oscillation afterwards. In addition, coherent phonons are generated, which is resonantly enhanced if the frequency of the order parameter oscillation is equal to the phonon frequency. For long pulses, the system is pushed into the adiabatic regime. In this regime, the order parameter is lowered during the pulse and remains almost constant afterwards. Further, there is almost no generation of coherent phonons. For the pump-probe response we compute the conductivity induced by the probe pulse. The conductivity is a typical observable in real pump-probe experiments. Hence, it is possible to

  4. Optimization of testing system and experiment research for pump turbine model

    Science.gov (United States)

    Y Li, D.; Wang, H. J.; Zhao, J. L.; Gong, R. Z.; Wei, X. Z.; Qin, D. Q.

    2013-12-01

    The pump turbine is key component of Pump Storage Power Plants. Moreover, the model testing proves significant guidance on design of pump turbine. Since pump turbine model testing is different from turbine model resulting from four quadrant experiment, point acquisition for transient operation conditions and special data processing, the optimization is made for these technological difficulties. In order to obtain a higher efficiency, a higher precision and a high degree of automation, the system of data acquisition is designed, in which the PXI platform was adopted, and the virtual instrument software LabVIEW was employed. And this system was successfully applied for the testing platform of Harbin Institute of Large Electric Machinery which achieves functions of transient conditions acquisition, measurement for positive and negative flow and speed, data processing, generating report, analysis for pressure fluctuation and so on. Finally four quadrant experiment was carried out in this test platform, results show that steady for the experiment operation conditions and repeatability for data which can better reflect the characteristic for "S-shaped" and reverse pump conditions. The system of pump turbine model test is significant for the research of pump turbine and has some guiding significance for the application of engineering.

  5. Factors influencing the performance and efficiency of solar water pumping systems:  a review

    OpenAIRE

    Gouws, Rupert; Lukhwareni, Thendo

    2012-01-01

    The world is having an energy crisis and currently there is a strong drive towards renewable energy. A renewable energy option is solar energy, where by means of photovoltaic (PV) modules electrical energy can be produced. A residential as well as industrial application for these PV modules is solar water pumping systems. Disadvantages of solar water pumping systems are low performance and low energy efficiency. This paper provides a review on the factors that influence the performance and ef...

  6. Theoretical study of heat pump system using CO2/dimethylether as refrigerant

    OpenAIRE

    Fan Xiao-Wei; Zhang Xian-Ping; Ju Fu-Jun; Wang Fang

    2013-01-01

    Nowadays, HCFC22 is widely used in heat pump systems in China, which should be phased out in the future. Thus, eco-friendly mixture CO2/dimethylether is proposed to replace HCFC22. Compared with pure CO2 and pure dimethylether, the mixture can reduce the heat rejection pressure, and suppress the flammability and explosivity of pure dimethylether. According to the Chinese National Standards on heat pump water heater and space heating system, performances of ...

  7. Energy Savings and Peak Demand Reduction of a SEER 21 Heat Pump vs. a SEER 13 Heat Pump with Attic and Indoor Duct Systems

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, J. [BA-PIRC/ Florida Solar Energy Center, Cocoa, FL (United States); Withers, C. [BA-PIRC/ Florida Solar Energy Center, Cocoa, FL (United States)

    2014-03-01

    This report describes results of experiments that were conducted in an unoccupied 1600 square foot house--the Manufactured Housing (MH Lab) at the Florida Solar Energy Center (FSEC)--to evaluate the delivered performance as well as the relative performance of a SEER 21 variable capacity heat pump versus a SEER 13 heat pump. The performance was evaluated with two different duct systems: a standard attic duct system and an indoor duct system located in a dropped-ceiling space.

  8. 78 FR 58273 - Approval for Manufacturing (Production) Authority, Foreign-Trade Zone 284, Liberty Pumps, Inc...

    Science.gov (United States)

    2013-09-23

    ..., Liberty Pumps, Inc. (Submersible and Water Pumps), Bergen, New York Pursuant to its authority under the..., grantee of Foreign-Trade Zone 284, has requested manufacturing (production) authority on behalf of Liberty... procedures within FTZ 284 on behalf of Liberty Pumps, Inc., as described in the application and Federal...

  9. Energy-saving control model of inverter for centrifugal pump systems

    Directory of Open Access Journals (Sweden)

    Yin Luo

    2015-06-01

    Full Text Available The inverter control strategy is the key to pump energy-saving operation and should be established based on the current system configurations and system requirements, which is not the case in practice. As a result, the characteristics of pump system requirements and a combination pump with inverter were studied, and the mathematical models were established. A new model for an optimal inverter control strategy based on the current system configurations and system requirements was then established, and a method combining golden section search and genetic algorithm was formulated to solve this optimal model. This model sets up an optimal inverter control strategy to increase the efficiency of pump operation following a process line near the minimum requirements to improve operation conditions. The implementation difficulty of the control law was also reduced. Finally, the optimized model was applied to an industrial circulating pump system, and the result showed that the model can not only determine the optimal inverter control strategy but also evaluate the current operation situation of the pump configuration and determine the energy-saving potential for the current configuration, which can aid in the subsequent energy-saving reconstruction.

  10. A review of selected pumping systems in nature and engineering--potential biomimetic concepts for improving displacement pumps and pulsation damping.

    Science.gov (United States)

    Bach, D; Schmich, F; Masselter, T; Speck, T

    2015-09-03

    The active transport of fluids by pumps plays an essential role in engineering and biology. Due to increasing energy costs and environmental issues, topics like noise reduction, increase of efficiency and enhanced robustness are of high importance in the development of pumps in engineering. The study compares pumps in biology and engineering and assesses biomimetic potentials for improving man-made pumping systems. To this aim, examples of common challenges, applications and current biomimetic research for state-of-the art pumps are presented. The biomimetic research is helped by the similar configuration of many positive displacement pumping systems in biology and engineering. In contrast, the configuration and underlying pumping principles for fluid dynamic pumps (FDPs) differ to a greater extent in biology and engineering. However, progress has been made for positive displacement as well as for FDPs by developing biomimetic devices with artificial muscles and cilia that improve energetic efficiency and fail-safe operation or reduce noise. The circulatory system of vertebrates holds a high biomimetic potential for the damping of pressure pulsations, a common challenge in engineering. Damping of blood pressure pulsation results from a nonlinear viscoelastic behavior of the artery walls which represent a complex composite material. The transfer of the underlying functional principle could lead to an improvement of existing technical solutions and be used to develop novel biomimetic damping solutions. To enhance efficiency or thrust of man-made fluid transportation systems, research on jet propulsion in biology has shown that a pulsed jet can be tuned to either maximize thrust or efficiency. The underlying principle has already been transferred into biomimetic applications in open channel water systems. Overall there is a high potential to learn from nature in order to improve pumping systems for challenges like the reduction of pressure pulsations, increase of jet

  11. 1998 Annual Status Report: Submersed and Floating-Leaf Vegetation in Pools 4, 8, 13, and 26 and La Grange Pool of the Upper Mississippi River System

    National Research Council Canada - National Science Library

    Yin, Yao

    2001-01-01

    Aquatic vegetation was investigated in five navigation pools in the Upper Mississippi River System using a new protocol named 'stratified random sampling' or SRS protocol for the first time in 1998...

  12. Low-thrust chemical propulsion system pump technology

    Science.gov (United States)

    Meadville, J. W.

    1980-01-01

    A study was conducted within the thrust range 450 to 9000 N (100 to 2000 pounds). Performance analyses were made on centrifugal, pitot, Barske, drag, Tesla, gear, piston, lobe, and vane pumps with liquid hydrogen, liquid methane, and liquid oxygen as propellants. Gaseous methane and hydrogen driven axial impulse turbines, vane expanders, piston expanders, and electric motors were studied as drivers. Data are presented on performance, sizes, weights, and estimated service lives and costs.

  13. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  14. Numerical and Experimental Investigation of Slanted Axial-flow pumping System

    Directory of Open Access Journals (Sweden)

    Fan Yang

    2013-07-01

    Full Text Available The Investigation of the three-dimensional (3D fluid flow inside a slanted axial pumping system, based on the Reynolds time-averaged Navier-Stokes equations and the RNG k-ε turbulent flow model, applying the multiple reference frames. The flow detail of whole slanted axial pumping system is attained. The relation between hydraulic performance of outlet sections with rotating impeller and installation height of pumping system and the stress distribution of impeller is analyzed, so is the relative velocity distribution near the airfoil cross sections under the designed condition. The hydraulic moment under different conditions was calculated based on the numerical results, and the changing features of hydraulic moment on blades with flow rates are analyzed. The reference nominal height of pump is put forward. The comparison of simulation results and the experiment data shows that the calculation performance closes agrees with the experiment results at the best efficiency and designed operating conditions, but under the condition of low rate, deviations exist between the two results. Using CFD method to simulate the internal flow field of slanted axial pumping system can provide the basis for the hydraulic design of the slanted axial pumping system or its optimization.

  15. Design of a Mechanical NaK Pump for Fission Space Power Systems

    Science.gov (United States)

    Mireles, Omar R.; Bradley, David; Godfroy, Thomas

    2010-01-01

    Alkali liquid metal cooled fission reactor concepts are under development for mid-range spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid. Traditionally, linear induction pumps have been used to provide the required flow and head conditions for liquid metal systems but can be limited in performance. This paper details the design, build, and check-out test of a mechanical NaK pump. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

  16. Dynamic Modeling, Control, and Analysis of a Solar Water Pumping System for Libya

    Directory of Open Access Journals (Sweden)

    Muamer M. Shebani

    2017-01-01

    Full Text Available In recent years, one of the suitable solar photovoltaic (PV applications is a water pumping system. The simplest solar PV pumping system consists of PV array, DC-DC converter, DC motor, and water pump. In this paper, water pumping system sizing for Libya is evaluated based on a daily demand using HOMER software, and dynamic modeling of a solar PV water pumping system using a Permanent Magnet DC (PMDC motor is presented in Matlab/Simulink environment. The system performance with maximum power point tracking (MPPT based on Fractional Open Circuit Voltage (FOCV is evaluated with and without a battery storage system. In some applications, a rated voltage is needed to connect a PMDC motor to a PV array through a DC-DC converter and in other applications the input voltage can vary. The evaluation of the system is based on the performance during a change in solar irradiation. Using Matlab/Simulink, simulation results are assessed to see the efficiency of the system when it is operating at a specific speed or at the MPPT. The results show that an improvement in the system efficiency can be achieved when the PMDC motor is running at a specific speed rather than at the peak PV power point.

  17. Design and optimization of a large flow rate booster pump in SWRO energy recovery system

    Science.gov (United States)

    Lai, Z. N.; Wu, P.; Wu, D. Z.; Wang, L. Q.

    2013-12-01

    Seawater reverse osmosis (SWRO) is a high energy-consumption industry, so energy efficiency is an important issue. Energy recovery systems, which contain a pressure exchanger and a booster pump, are widely used in SWRO plants. As a key part of energy recovery system, the difficulty of designing booster pumps lies in high inlet pressure, high medium causticity and large flow rate. High inlet pressure adds difficulties to seal design, and large flow rate and high efficiency requirement bring high demand for hydraulic design. In this paper, a 625 m3/h booster pump is designed and optimized according to the CFD (Computational Fluid Dynamics) simulation results. The impeller and volute is well designed, a new type of high pressure mechanical seal is applied and axial force is well balanced. After optimization based on blade redesign, the efficiency of the pump was improved. The best efficiency reaches more than 85% at design point according to the CFD simulation result.

  18. A fuzzy global efficiency optimization of a photovoltaic water pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Benlarbi, K.; Nait-Said, M.S. [Batna Univ. (Algeria). Dept. of Electrical Engineering; Mokrani, L. [Laghouat Univ. (Algeria). Materials Lab.

    2004-07-01

    This paper presents an on-line fuzzy optimization of the global efficiency of a photovoltaic water pumping system driven by a separately excited DC motor (DCM), a permanent magnet synchronous motor (PMSM), or an induction motor (IM), coupled to a centrifugal pump. The fuzzy optimization procedure stated above, which aims to the maximization of the global efficiency, will lead consequently to maximize the drive speed and the water discharge rate of the coupled centrifugal pump. The proposed solution is based on a judicious fuzzy adjustment of a chopper ratio which adapts on-line the load impedance to the photovoltaic generator (PVG). Simulation results show the effectiveness of the drive system for both transient and steady state operations. Hence it is suitable to use this fuzzy logic procedure as a standard optimization algorithm for such photovoltaic water pumping drives. (author)

  19. Molecular Dynamics Simulation of Valveless Pumping in a Closed Nanofluidic Tube System

    DEFF Research Database (Denmark)

    Hansen, Jesper S.; Ottesen, Johnny T.

    2009-01-01

    In this paper we perform a realistic nonequilibrium molecular dynamics simulation of valveless pumping in a closed nanofluidic tube system. It is shown that the simple pumping mechanism can generate a uni-directional mean flow on very small length and times scales, thereby overcoming the technical...... difficulties often encountered when manufacturing more complex pumping devices. From the molecular dynamics simulation we obtain the spatio temporal dynamics of the pressure. The molecular dynamics results are substituted into the Navier-Stokes equation and we are then able to extract the local streaming...... velocity profiles sufficiently far away from the pumping device. The mean streaming velocity is compared with molecular dynamics data showing excellent agreement. Detailed knowledge about these profiles will be valuable for future investigation of this remarkable system....

  20. Analysis of Electric Propulsion Performance on Submersible with Motor DC, Supply Power 10260AH at Voltage 115VDC

    Directory of Open Access Journals (Sweden)

    Indra Ranu Kusuma

    2017-03-01

    Full Text Available Electric propulsion is the ship system using propulsion motor to replace performance of main engine. The application of diesel engine as propulsion system have some problems and weaknesses such as diesel engine unability to operate when submersible vessel is operating under sea. To overcome that problems in submersible vessel, alternative solution of ship propulsion is required. DC Motor can be used as this alternative solution. Submersible vessel use electric propulsion system with DC Motor because DC Motor has advantages of easy rotation setting and does not cause noise when submersible vessel is diving. This bachelor thesis will study the application of DC Motor as an electric propulsion system on submersible vessel with length 59,57 m in series and parallel circuit by simulation using MATLAB software. The simulation data obtained are rotation and torque of DC Motor. From these simulation, it can be concluded that parallel circuit rotation is greater than series circuit rotation. It caused the greater speed and lower power in parallel circuit. 

  1. Liquid oxygen/liquid hydrogen boost/vane pump for the advanced orbit transfer vehicles auxiliary propulsion system

    Science.gov (United States)

    Gluzek, F.; Mokadam, R. G.; To, I. H.; Stanitz, J. D.; Wollschlager, J.

    1979-01-01

    A rotating, positive displacement vane pump with an integral boost stage was designed to pump saturated liquid oxygen and liquid hydrogen for auxiliary propulsion system of orbit transfer vehicle. This unit is designed to ingest 10% vapor by volume, contamination free liquid oxygen and liquid hydrogen. The final pump configuration and the predicted performance are included.

  2. Modern methods of high-pressure fuel pump common rail power system diagnostics

    Directory of Open Access Journals (Sweden)

    Kyshchun В.

    2016-08-01

    Full Text Available We've considered high pressure fuel pumps design features and equipment for their diagnosis. It was noted that the reliability of the fuel elements Common Rail system primarily provide precision parts of the fuel equipment. As a consequence, the aim of study was comparative analysis and laborious of modern methods of the high pressure fuel pump diagnosing. In particular, the definition of a technical condition of the fuel pump was carried out using a special stand and by measuring the fuel pressure and duty cycle of the pressure regulator signal. As an object of our research we've chosen Bosch № 0445010008 fuel pump (from Mercedes Benz E320cdi in which the plunger pairs were changed alternately with different technical conditions. Preliminary fuel pump parameters were determined by hydraulic testing. Based on conducted experiments we've found out that fuel pressure measurement change method and the duty cycle of the pressure regulator signal at the starting and full load modes less laborious compared to the definition of a technical condition of the pump on the stand. The results of both methods of diagnosing confirmed identity of the fuel pumps.

  3. Two-phase cooling system with a jet pump for spacecraft

    Science.gov (United States)

    Fairuzov, Yuri V.; Bredikhin, Victor V.

    1995-04-01

    A two-phase cooling system with a jet pump is proposed for the thermal control of spacecraft. The system does not require an external source of energy, the pumping of the working fluid is performed by the work that is produced in a thermodynamic cycle being carried out in the heat transport loop. The cooling system has no moving parts or control devices, with the exception of a mechanical pump and an actuated valve, that are used only for the startup sequence. This article reports on the results of the theoretical and experimental studies of the two-phase thermal control system with a jet pump for spacecraft application. A mathematical model for the steady-state analysis of the proposed system was developed. The model was applied to predict overall performance characteristics and operating range for a specific spacecraft two-phase cooling system. The possible reasons for the fluid loop operation failures were identified. The influence of the accumulator volume on the system characteristics was also investigated. Three jet pumps of various configurations were tested and stable operational regimes of the cooling system were obtained under different heat-load and heat-rejection conditions on a ground experimental facility.

  4. Heat pump centered integrated community energy systems: system development. Georgia Institute of Technology final report

    Energy Technology Data Exchange (ETDEWEB)

    Wade, D.W.; Trammell, B.C.; Dixit, B.S.; McCurry, D.C.; Rindt, B.A.

    1979-12-01

    Heat Pump Centered-Integrated Community Energy Systems (HP-ICES) show the promise of utilizing low-grade thermal energy for low-quality energy requirements such as space heating and cooling. The Heat Pump - Wastewater Heat Recovery (HP-WHR) scheme is one approach to an HP-ICES that proposes to reclaim low-grade thermal energy from a community's wastewater effluent. This report develops the concept of an HP-WHR system, evaluates the potential performance and economics of such a system, and examines the potential for application. A thermodynamic performance analysis of a hypothetical system projects an overall system Coefficient of Performance (C.O.P.) of from 2.181 to 2.264 for waste-water temperatures varying from 50/sup 0/F to 80/sup 0/F. Primary energy source savings from the nationwide implementation of this system is projected to be 6.0 QUADS-fuel oil, or 8.5 QUADS - natural gas, or 29.7 QUADS - coal for the period 1980 to 2000, depending upon the type and mix of conventional space conditioning systems which could be displaced with the HP-WHR system. Site-specific HP-WHR system designs are presented for two application communities in Georgia. Performance analyses for these systems project annual cycle system C.O.P.'s of 2.049 and 2.519. Economic analysis on the basis of a life cycle cost comparison shows one site-specific system design to be cost competitive in the immediate market with conventional residential and light commercial HVAC systems. The second site-specific system design is shown through a similar economic analysis to be more costly than conventional systems due mainly to the current low energy costs for natural gas. It is anticipated that, as energy costs escalate, this HP-WHR system will also approach the threshold of economic viability.

  5. Optimal hydraulic design of new-type shaft tubular pumping system

    Science.gov (United States)

    Zhu, H. G.; Zhang, R. T.; Zhou, J. R.

    2012-11-01

    Based on the characteristics of large flow rate, low-head, short annual operation time and high reliability of city flood-control pumping stations, a new-type shaft tubular pumping system featuring shaft suction box, siphon-type discharge passage with vacuum breaker as cutoff device was put forward, which possesses such advantages as simpler structure, reliable cutoff and higher energy performance. According to the design parameters of a city flood control pumping station, a numerical computation model was set up including shaft-type suction box, siphon-type discharge passage, pump impeller and guide vanes. By using commercial CFD software Fluent, RNG κ-epsilon turbulence model was adopted to close the three-dimensional time-averaged incompressible N-S equations. After completing optimal hydraulic design of shaft-type suction box, and keeping the parameters of total length, maximum width and outlet section unchanged, siphon-type discharge passages of three hump locations and three hump heights were designed and numerical analysis on the 9 hydraulic design schemes of pumping system were proceeded. The computational results show that the changing of hump locations and hump heights directly affects the internal flow patterns of discharge passages and hydraulic performances of the system, and when hump is located 3.66D from the inlet section and hump height is about 0.65D (D is the diameter of pump impeller), the new-type shaft tubular pumping system achieves better energy performances. A pumping system model test of the optimal designed scheme was carried out. The result shows that the highest pumping system efficiency reaches 75.96%, and when at design head of 1.15m the flow rate and system efficiency were 0.304m3/s and 63.10%, respectively. Thus, the validity of optimal design method was verified by the model test, and a solid foundation was laid for the application and extension of the new-type shaft tubular pumping system.

  6. A Novel Pumped Hydro Combined with Compressed Air Energy Storage System

    Directory of Open Access Journals (Sweden)

    Erren Yao

    2013-03-01

    Full Text Available A novel pumped hydro combined with compressed air energy storage (PHCA system is proposed in this paper to resolve the problems of bulk energy storage in the wind power generation industry over an area in China, which is characterised by drought and water shortages. Thermodynamic analysis of the energy storage system, which focuses on the pre-set pressure, storage volume capacity, water air volume ratio, pump performance, and water turbine performance of the storage system, is also presented. This paper discovers how such parameters affect the performance of the whole system. The ideal performance of this novel system has the following advantages: a simple, highly effective and low cost structure, which is comparable to the efficiency of a traditional pumped hydro storage system. Research results show a great solution to the current storage constraints encountered in the development of the wind power industry in China, which have been widely recognised as a bottleneck in the wind energy storage industry.

  7. Feasibility study of a wind powered water pumping system for rural Ethiopia

    Directory of Open Access Journals (Sweden)

    Misrak Girma

    2015-12-01

    Full Text Available Water is the primary source of life for mankind and one of the most basic necessities for rural development. Most of the rural areas of Ethiopia do not have access to potable water. Is some regions of the country access potable water is available through use of manual pumping and Diesel engine. In this research, wind water pump is designed to supply drinking water for three selected rural locations in Ethiopia. The design results show that a 5.7 m diameter windmill is required for pumping water from borehole through a total head of 75, 66 and 44 m for Siyadberand Wayu, Adami Tulu and East Enderta to meet the daily water demand of 10, 12 and 15 m3, respectively. The simulation for performance of the selected wind pump is conducted using MATLAB software and the result showed that monthly water discharge is proportional to the monthly average wind speed at the peak monthly discharge of 685 m3 in June, 888 m3 in May and 1203 m3 in March for Siyadberand Wayu, Adami Tulu and East Enderta sites, respectively. An economic comparison is conducted, using life cycle cost analysis, for wind mill and Diesel water pumping systems and the results show that windmill water pumping systems are more feasible than Diesel based systems.

  8. Heat pump centered integrated community energy systems: system development. Georgia Institute of Technology interim report

    Energy Technology Data Exchange (ETDEWEB)

    Wade, D W; Trammel, B C; Dixit, B S; McCurry, D C; Rindt, B A

    1979-02-01

    Heat Pump Centered-Integrated Community Energy Systems (HP-ICES) show the promise of utilizing low-grade thermal energy for low-quality energy requirements such as space heating and cooling. The Heat Pump - Wastewater Heat Recovery (HP-WHR) scheme is one approach to an HP-ICES that proposes to reclaim low-grade thermal energy from a community's wastewater effluent. The concept of an HP-WHR system is developed, the potential performance and economics of such a system is evaluated and the potential for application is examined. A thermodynamic performance analysis of a hypothetical system projects an overall system coefficient of performance (C.O.P.) of from 2.181 to 2.264 for wastewater temperatures varying from 50/sup 0/F to 80/sup 0/F. Primary energy source savings from the implementation of this system is projected to be 5.014 QUADS, or the energy equivalent of 687 millions tons of coal, from 1980 to the year 2000. Economic analysis shows the HP-WHR scheme to be cost-competitive, on the basis of a net present value life cycle cost comparison, with conventional residential and light commercial HVAC systems.

  9. A comparison of diesel, biodiesel and solar PV-based water pumping systems in the context of rural Nepal

    DEFF Research Database (Denmark)

    Parajuli, Ranjan; Pokharel, Govind Raj; Østergaard, Poul Alberg

    2014-01-01

    using petro-diesel, jatropha-based biodiesel and solar photovoltaic pumps. The technical system design consists of system sizing of prime mover (engine, solar panel and pumps) and estimation of reservoir capacity, which are based on the annual aggregate water demand modelling. With these investigations...... area, the levelised cost of pumping 1 L of water is higher than that of a solar pump and even higher when compared with diesel, if the seed yield per plant is less than 2 kg and without subsidy on the investment cost of cultivation and processing. With the productivity of 2.5 kg/plant, a biodiesel......-based system is more attractive than that of the diesel-based pump, but still remains more expensive than that of solar pump. From the technical perspective (reliability and easiness in operation) and economic evaluation of the technical alternatives, solar pumping system is found to be the most viable...

  10. DPAL pump system exceeding 3kW at 766nm and 30 GHz bandwidth

    Science.gov (United States)

    Koenning, Tobias; McCormick, Dan; Irwin, David; Stapleton, Dean; Guiney, Tina; Patterson, Steve

    2016-03-01

    Due to their low quantum defect, diode pumped alkali metal vapor lasers (DPALs) offer the promise of scalability to very high average power levels while maintaining excellent beam quality. Research on DPALs has progressed to ever increasing power levels across multiple gain media species over the last years, necessitating pump power in the kW range. Each material requires a specific pump wavelength: near 852nm for cesium, 780nm for rubidium, 766nm for potassium, and 670nm for lithium atoms. The shorter pump wavelength below 800nm are outside the typical wavelength range for pump diodes developed for diode pumped solid state lasers (DPSS). The biggest challenge in pumping these materials efficiently is the need for maintaining the narrow gain media absorption band of approximately 0.01nm while greatly increasing power. Typical high power diode lasers achieve spectral widths around 3nm (FWHM) in the near infrared spectrum, but optical gratings may be used internal or external to the cavity to reduce the spectral width. Recently, experimental results have shown yet narrower line widths ranging from picometers at very low power levels to sub-100 picometers for water cooled stacks around 1kW of output power. The focus of this work is the development of a fiber-based pump system for potassium DPAL. The individual tasks are the development of high power 766nm chip material, a fiber-coupled module as a building block, and a scalable system design to address power requirements from hundreds of watts to tens of kilowatts. Results for a 3kW system achieving ~30GHz bandwidth at 766nm will be shown. Approaches for power-scaling and size reduction will be discussed.

  11. Hydrodynamic optimization of trust ring pump and lubricating oil system for large hydroelectric units thrust bearing

    Science.gov (United States)

    Lai, X.; Lu, Z.; Zhang, X.; Yang, S.

    2014-03-01

    Thrust-ring-pump is a kind of extreme-low specific speed centrifugal pump with special structure as numerous restrictions form thrust bearing and operation conditions of hydro turbine generator unit. Because the oil circulating and cooling system with thrust-ring- pump has a lot of advantages in maintenance and compactness in structure, it has widely been used in large and medium-sized hydro-generator units. Since the diameter and the speed of the thrust ring is limited by the generator set, the matching relationship between the flow passage inside the thrust ring (equivalent to impeller) and oil bath (equivalent to volute) has great influence on hydrodynamic performance of thrust-ring-pump, additionally, the head and discharge are varying with the operation conditions of hydro-generator unit and characteristic of the oil circulating and cooling system. As so far, the empirical calculation method is employed during the actual engineering design, in order to guarantee the operating performance of the oil circulating and cooling system with thrust-ring-pump at different conditions, a collaborative hydrodynamic design and optimization of both the oil circulating and cooling system and thrust-ring-pump is purposed in this paper. Firstly, the head and discharge required at different conditions are decided by 1D flow numerical simulation of the oil circulating and cooling system. Secondly, the flow passages of thrust-ring-pump are empirically designed under the restrictions of diameter and the speed of the thrust ring according to the head and discharge from the simulation. Thirdly, the flow passage geometry matching optimization between holes inside the thrust ring and oil bath is implemented by means of 3D flow simulation and performance prediction. Then, the pumps and the oil circulating and cooling system are collaborative hydrodynamic optimized with predicted head- discharge curve and the efficiency-discharge curve of thrust-ring-pump. The presented methodology has

  12. Heat pumps. Vapor compression systems; Pompes a chaleur. Systemes a compression de vapeur

    Energy Technology Data Exchange (ETDEWEB)

    Auzenet, E.; Clerc-Renaud, M. [Centre de Recherche et Developpement de la Compagnie Industrielle d' Applications Thermiques (CIAT), 01 - Culoz (France)

    2005-09-01

    Derived from refrigerating applications, heat pumps were limited to low heating temperature levels for a long time. The economic conditions, the prices of traditional energies, and the lack of maturity of the market were brakes to their development during the last decades. The recent development of new technologies, in particular pushed by the new regulations about refrigerants, will lead to the development and mass production of efficient products capable to heat water at temperature levels suitable for space heating and hot water production applications. Their coupling with other systems that use renewable energy sources must be one of tomorrows' research path. This article recalls the theoretical operation principles and the different possible designs and technologies for heat pumps: 1 - theory: theoretical scheme and general principle of operation; 2 - technology: compressors, heat exchangers, pressure release parts, auxiliary refrigerating components, example of refrigeration schemes; 3 - heat sources: air cold source, ground cold source, water cold source, coupling with solar collectors, water loop heat pump. (J.S.)

  13. The Performance Test Procedure for the Mechanical Sodium Pump installed in STELLA-1

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chungho; Han, Ji-Woong; Kim, Tae-Joon; Hwang, Inkoo; Hong, Jonggan; Yeom, Sujin; Lee, Jewhan; Kim, Jong-Man; Cho, Youngil; Jung, Min-Hwan; Gam, Da-Young; Eoh, Jae-Hyuk; Jeong, Ji-Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    STELLA-1 (Sodium inTegral Effect test Loop for safety simuLation and Assessment) is a large-scale separate effect test facility for demonstrating the thermal-hydraulic performances of major components such as a Sodium-to-Sodium heat exchanger (DHX), Sodium-to-Air heat exchanger (AHX) of the decay heat removal system, and mechanical sodium pump of the primary heat transport system, which are important to ensure the safety of the sodium-cooled fast reactor (SFR). A mechanical sodium pump, the test component, was scaled down to preserve the major thermal-hydraulic phenomena according to the related similarity criteria using the corresponding prototype pump of the 600 MWe demonstration SFR (DSFR). The vertical submersible prototypic pump had a rated flow rate of 17,415 m{sup 3}/h, a rated pressure head of 62.9 m, and a rated rotational speed of 433 rpm, and the model pump was scaled down while keeping the same specific speed. The model pump had a rated flow rate of 510 m{sup 3}/h, a rated pressure head of 50.3 m, and a rated rotational speed of 2,140 rpm. The present paper describes the performance test procedures for the mechanical sodium pump installed in STELLA-1.

  14. Human Health Science Building Geothermal Heat Pump Systems

    Energy Technology Data Exchange (ETDEWEB)

    Leidel, James [Oakland Univ., Rochester, MI (United States)

    2014-12-22

    The grant objectives of the DOE grant funded project have been successfully completed. The Human Health Building (HHB) was constructed and opened for occupancy for the Fall 2012 semester of Oakland University. As with any large construction project, some issues arose which all were overcome to deliver the project on budget and on time. The facility design is a geothermal / solar-thermal hybrid building utilizing both desiccant dehumidification and variable refrigerant flow heat pumps. It is a cooling dominant building with a 400 ton cooling design day load, and 150 ton heating load on a design day. A 256 vertical borehole (320 ft depth) ground source heat pump array is located south of the building under the existing parking lot. The temperature swing and performance over 2013 through 2015 shows the ground loop is well sized, and may even have excess capacity for a future building to the north (planned lab facility). The HHB achieve a US Green Building Counsel LEED Platinum rating by collecting 52 of the total 69 available LEED points for the New Construction v.2 scoring checklist. Being Oakland's first geothermal project, we were very pleased with the building outcome and performance with the energy consumption approximately 1/2 of the campus average facility, on a square foot basis.

  15. High efficient ammonia heat pump system for industrial process water using the ISEC concept. Part 2

    DEFF Research Database (Denmark)

    Olesen, Martin F.; Madsen, Claus; Olsen, Lars

    2014-01-01

    The Isolated System Energy Charging (ISEC) concept allows for a high efficiency of a heat pump system for hot water production. The ISEC concept consists of two water storage tanks, one charged and one discharged. The charged tank is used for the industrial process, while the discharged tank is c...... modelling of the heat pump and tank system is performed (in continuation of Part I). The modelling is extended to include the system performance with different natural refrigerants and the influence of different types of compressors....

  16. Feasibility study of a solar photovoltaic water pumping system for rural Ethiopia

    Directory of Open Access Journals (Sweden)

    Misrak Girma

    2015-06-01

    Full Text Available Solar Photovoltaic (SPV water pumping system is one of the best technologies that utilize the solar energy to pump water from deep well underground water sources and to provide clean drinking water worldwide. The availability of abundant solar radiation and enough underground water sources in Ethiopia can be combined together to make clean drinking water available to rural communities. The software PVsyst 5.56 was used to study the feasibility of solar photovoltaic water pumping system in the selected sites. The designed system is capable of providing a daily average of 10.5, 7 and 6.5 m3/day for 700, 467 and 433 people in Siadberand Wayu, Wolmera and Enderta sites respectively, with average daily water consumption of 15 liters per day per person and the costs of water without any subsidy, are approximately 0.1, 0.14 and 0.16 $/m3for each site respectively. If diesel generator is used instead of solar photovoltaic water pumping system, to provide the same average daily water for the selected community, the costs of water without any subsidy are approximately 0.2, 0.23 and 0.27 $/m3 for each site respectively. A life cycle cost analysis method was also carried out for economic comparison between solar PV and the diesel pumping system. The results of this study are encouraging the use of the PV system for drinking water supply in the remote areas of the country.

  17. Design of DC Conduction Pump for PGSFR Active Decay Heat Removal System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dehee; Hong, Jonggan; Lee, Taeho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    A DC conduction pump has been designed for the ADHRS of PGSFR. A VBA code developed by ANL was utilized to design and optimize the pump. The pump geometry dependent parameters were optimized to minimize the total current while meeting the design requirements. A double-C type dipole was employed to produce the calculated magnetic strength. Numerical simulations for the magnetic field strength and its distribution around the dipole and for the turbulent flow under magnetic force will be carried out. A Direct Current (DC) conduction Electromagnetic Pump (EMP) has been designed for Active Decay Heat Removal System (ADHRS) of PGSFR. The PGSFR has active as well as passive systems for the DHRS. The passive DHRS (PDHRS) works by natural circulation head and the ADHRS is driven by an EMP for the DHRS sodium loop and a blower for the finned-tube sodium-to-air heat exchanger (FHX). An Annular Linear Induction Pump (ALIP) can be also considered for the ADHRS, but DC conduction pump has been chosen. Selection basis of DHRS EMP is addressed and EMP design for single ADHRS loop with 1MWt heat removal capacity is introduced.

  18. Development of laser diode-pumped high average power solid-state laser for the pumping of Ti:sapphire CPA system

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Yoichiro; Tei, Kazuyoku; Kato, Masaaki; Niwa, Yoshito; Harayama, Sayaka; Oba, Masaki; Matoba, Tohru; Arisawa, Takashi; Takuma, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    Laser diode pumped all solid state, high repetition frequency (PRF) and high energy Nd:YAG laser using zigzag slab crystals has been developed for the pumping source of Ti:sapphire CPA system. The pumping laser installs two main amplifiers which compose ring type amplifier configuration. The maximum amplification gain of the amplifier system is 140 and the condition of saturated amplification is achieved with this high gain. The average power of fundamental laser radiation is 250 W at the PRF of 200 Hz and the pulse duration is around 20 ns. The average power of second harmonic is 105 W at the PRF of 170 Hz and the pulse duration is about 16 ns. The beam profile of the second harmonic is near top hat and will be suitable for the pumping of Ti:sapphire laser crystal. The wall plug efficiency of the laser is 2.0 %. (author)

  19. Heat-pump-centered integrated community energy systems: System development summary

    Science.gov (United States)

    Calm, J. M.

    1980-02-01

    An introduction to district heating systems employing heat pumps to enable use of low temperature energy sources is presented. These systems operate as thermal utilities to provide space heating and may also supply space cooling, service water heating, and other thermal services. Otherwise wasted heat from industrial and commercial processes, natural sources including solar and geothermal heat, and heat stored on an annual cycle from summer cooling may be effectively utilized by the systems described. More than one quarter of the energy consumed in the United States is used to heat and cool buildings and to heat service water. Natural gas and oil provide approximately 83% of this energy. The systems described show potential to reduce net energy consumption for these services by 20 to 50% and to allow fuel substitution with less scarce resources not practical in smaller, individual building systems. Seven studies performed for the system development phase are summarized.

  20. Residential CO{sub 2} heat pump system for combined space heating and hot water heating

    Energy Technology Data Exchange (ETDEWEB)

    Stene, Joern

    2004-02-01

    Carbon dioxide (CO{sub 2}, R-744) has been identified as a promising alternative to conventional working fluids in a number of applications due to its favourable environmental and thermophysical properties. Previous work on residential CO{sub 2} heat pumps has been dealing with systems for either space heating or hot water heating, and it was therefore considered interesting to carry out a theoretical and experimental study of residential CO{sub 2} heat pump systems for combined space heating and hot water heating - o-called integrated CO{sub 2} heat pump systems. The scope of this thesis is limited to brine-to-water and water-to-water heat pumps connected to low-temperature hydronic space heating systems. The main conclusions are: (1) Under certain conditions residential CO{sub 2} heat pump systems for combined space heating and hot water heating may achieve the same or higher seasonal performance factor (SPF) than the most energy efficient state-of-the-art brine-to-water heat pumps. (2) In contrary to conventional heat pump systems for combined space heating and DHW heating, the integrated CO{sub 2} heat pump system achieves the highest COP in the combined heating mode and the DHW heating mode, and the lowest COP in the space heating mode. Hence, the larger the annual DHW heating demand, the higher the SPF of the integrated CO{sub 2} heat pump system. (3) The lower the return temperature in the space heating system and the lower the DHW storage temperature, the higher the COP of the integrated CO{sub 2} heat pump. A low return temperature in the space heating system also results in a moderate DHW heating capacity ratio, which means that a relatively large part of the annual space heating demand can be covered by operation in the combined heating mode, where the COP is considerably higher than in the space heating mode. (4) During operation in the combined heating mode and the DHW heating mode, the COP of the integrated CO{sub 2} heat pump is heavily influenced by

  1. Technical Information to Support Double Shell Tank (DST) Emergency Annulus Pumping [SEC 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    REBERGER, D.W.

    2000-09-14

    This document provides the design calculations for the DST Annulus Emergency Pumping Project. This document also contains essential information relative to DST annulus emergency pumping that may not be found in other documents. This information consists of the following: Index drawing for annulus pumping; References to the Acceptance Test Report, DST Emergency Pumping Guide, Time Deployment study, etc.; Statements of work; and Reference CEIS and RMIS numbers. A Vendor Information document, VI-50121, is not included in this document, but a copy can be obtained by contacting Document Control Services. This document contains various information regarding the Hydrostar pumps, such as the air motor, cylinder size, pump installation and operation manual. It also contains information regarding the Flygt BS2060 submersible pump, such as parts list, pump handling, preventative maintenance, overhaul and repair. In addition, this document also has information on 3-way PM ball valves, electrical skid components and the alternate Gurman-Rupp stainless steel submersible pump.

  2. The study on optimal operation of compound heat-pump system

    Science.gov (United States)

    Shin, Kwan-Woo; Kim, Ilhyun; Kim, Yong-Tae

    2007-12-01

    Heat-pump system has a special feature that provides heating operation in winter season and cooling operation in summer season with a single system. It also has a merit that absorbs and makes use of wastewater heat, terrestrial heat, and heat energy from the air. Because heat-pump system uses midnight electric power, it decreases power peak load and is very economical as a result. By using the property that energy source is converted to low temperature when losing the heat, high temperature energy source is used to provide heating water and low temperature energy source is used to provide cooling water simultaneously in summer season. This study made up a heat-pump system with 4 air heat sources and a water heat source and implemented the optimal operation algorithm that works with numbers of heat pumps to operate them efficiently. With the heat-pump system, we applied it to cooling and heating operation in summer season and in winter season operation mode in a real building.

  3. Stand-Alone Solar Organic Rankine Cycle Water Pumping System and Its Economic Viability in Nepal

    Directory of Open Access Journals (Sweden)

    Suresh Baral

    2015-12-01

    Full Text Available The current study presents the concept of a stand-alone solar organic Rankine cycle (ORC water pumping system for rural Nepalese areas. Experimental results for this technology are presented based on a prototype. The economic viability of the system was assessed based on solar radiation data of different Nepalese geographic locations. The mechanical power produced by the solar ORC is coupled with a water pumping system for various applications, such as drinking and irrigation. The thermal efficiency of the system was found to be 8% with an operating temperature of 120 °C. The hot water produced by the unit has a temperature of 40 °C. Economic assessment was done for 1-kW and 5-kW solar ORC water pumping systems. These systems use different types of solar collectors: a parabolic trough collector (PTC and an evacuated tube collector (ETC. The economic analysis showed that the costs of water are $2.47/m3 (highest and $1.86/m3 (lowest for the 1-kW system and a 150-m pumping head. In addition, the cost of water is reduced when the size of the system is increased and the pumping head is reduced. The minimum volumes of water pumped are 2190 m3 and 11,100 m3 yearly for 1 kW and 5 kW, respectively. The payback period is eight years with a profitability index of 1.6. The system is highly feasible and promising in the context of Nepal.

  4. EXERGY-BASED ECOLOGICAL ANALYSIS OF GENERALIZED IRREVERSIBLE HEAT PUMP SYSTEM

    Directory of Open Access Journals (Sweden)

    GOVIND MAHESHWARI

    2011-10-01

    Full Text Available A reverse Carnot cycle forms the basis of all heat-pump cycles in providing heating and cooling loads. The optimal exergy-based Ecological analysis of an irreversible Heat-pump system with the losses of heat resistance, heat leak and internal irreversibility has been carried out by taking into account Exergy based ecological function (E as an objective in the viewpoint of Finite-Time-Thermodynamics (FTT or Entropy Generation Minimization (EGM. Exergy is defined here as the power required minus the lost power. The effects of irreversibilities along with internal heat leakage on coefficient on the performance of the system are investigated. The exergy based Ecological function decreases steadily with irreversibilites and heat leakages in the system. COP in such a system increases with the cycle temperature ratio. If a heat pump cycle is optimized with above mentioned criterion, there is a trade-off between its coefficient of Performance and the heating load it provides.

  5. Controlling Price-Responsive Heat Pumps for Overload Elimination in Distribution Systems

    DEFF Research Database (Denmark)

    Csetvei, Zsuzsa; Østergaard, Jacob; Nyeng, Preben

    2011-01-01

    This paper investigates the possibility of applying electric heat pumps with the control-by-price-concept in order to avoid overload in a local distribution system. The proposed control algorithm is based upon a centrally dispatched real-time market price, reflecting the state of a larger power...... system, and is extended with a local price control for overload elimination on the corresponding feeder. The paper presents the mathematical models of a two-node system with price-responsive heat pumps, the chosen methodology of the central price calculation, and the proposed local feedback control...

  6. The pump, the exchanger, and the holy spirit: origins and 40-year evolution of ideas about the ouabain-Na+pump endocrine system.

    Science.gov (United States)

    Blaustein, Mordecai P

    2018-01-01

    Two prescient 1953 publications set the stage for the elucidation of a novel endocrine system: Schatzmann's report that cardiotonic steroids (CTSs) are all Na + pump inhibitors, and Szent-Gyorgi's suggestion that there is an endogenous "missing screw" in heart failure that CTSs like digoxin may replace. In 1977 I postulated that an endogenous Na + pump inhibitor acts as a natriuretic hormone and simultaneously elevates blood pressure (BP) in salt-dependent hypertension. This hypothesis was based on the idea that excess renal salt retention promoted the secretion of a CTS-like hormone that inhibits renal Na + pumps and salt reabsorption. The hormone also inhibits arterial Na + pumps, elevates myocyte Na + and promotes Na/Ca exchanger-mediated Ca 2+ gain. This enhances vasoconstriction and arterial tone-the hallmark of hypertension. Here I describe how those ideas led to the discovery that the CTS-like hormone is endogenous ouabain (EO), a key factor in the pathogenesis of hypertension and heart failure. Seminal observations that underlie the still-emerging picture of the EO-Na + pump endocrine system in the physiology and pathophysiology of multiple organ systems are summarized. Milestones include: 1) cloning the Na + pump isoforms and physiological studies of mutated pumps in mice; 2) discovery that Na + pumps are also EO-triggered signaling molecules; 3) demonstration that ouabain, but not digoxin, is hypertensinogenic; 4) elucidation of EO's roles in kidney development and cardiovascular and renal physiology and pathophysiology; 5) discovery of "brain ouabain", a component of a novel hypothalamic neuromodulatory pathway; and 6) finding that EO and its brain receptors modulate behavior and learning.

  7. CO2 as a heat pump working fluid for retrofitting hydronic heating systems in Western Europe

    Energy Technology Data Exchange (ETDEWEB)

    Enkemann, T.; Kruse, H. [FKW Research Center for Refrigeration and Heat Pumps, University of Hannover, Hannover (Germany); Oostendorp, P.A. [TNO Institute of Environmental Sciences, Energy Research and Process Innovation TNO-MEP, Apeldoorn (Netherlands)

    1998-12-31

    The use of heat pumps instead of conventional heating systems seems to be a promising way to reduce CO2 emissions contributing to the global warming impact in the field of space heating. Concerning the equipment of new buildings one can see a growing market for heat pumps in some cases due to governmental supporting measures. Since the number of existing buildings is much higher than the number of new buildings, the use of heat pumps should also be expanded to this market. Due to the design of the older systems with high supply temperatures of the hydronic heating system the application of existing heat pumps is limited. The transcritical process with CO2 seems to be promising for this application. Cycle calculations considering the typical design of existing heating systems were made to obtain information about the cycle characteristics and the energetic behavior of a CO2 heat pump in such a system. The calculations were done for an air to water heat pump since this type is better suited for all-purpose installation for retrofit. It was found that a control of the high side pressure of the heat pump cycle is recommended to achieve a high COP for all seasonary conditions of the heat sink and the heat source as well as for the behavior of the volumetric heating capacity. The use of an internal heat exchanger is however not recommended since the advantages concerning COP and the behavior of the volumetric heating capacity is negligible while it leads to significantly higher discharge temperatures. Seasonal performance factors (SPF) were estimated on the basis of cycle calculations. For a heating system with design supply and return temperatures of 70C and 50C a value of 2.8 was found. In order to optimize the heat pump performance, a modification of the usual design of the heating system is proposed. The temperature difference between supply and return should be enlarged by reducing the mass flow of the water in the existing hydronic system. Calculations show that

  8. Modeling and Optimization of a CoolingTower-Assisted Heat Pump System

    Directory of Open Access Journals (Sweden)

    Xiaoqing Wei

    2017-05-01

    Full Text Available To minimize the total energy consumption of a cooling tower-assisted heat pump (CTAHP system in cooling mode, a model-based control strategy with hybrid optimization algorithm for the system is presented in this paper. An existing experimental device, which mainly contains a closed wet cooling tower with counter flow construction, a condenser water loop and a water-to-water heat pump unit, is selected as the study object. Theoretical and empirical models of the related components and their interactions are developed. The four variables, viz. desired cooling load, ambient wet-bulb temperature, temperature and flow rate of chilled water at the inlet of evaporator, are set to independent variables. The system power consumption can be minimized by optimizing input powers of cooling tower fan, spray water pump, condenser water pump and compressor. The optimal input power of spray water pump is determined experimentally. Implemented on MATLAB, a hybrid optimization algorithm, which combines the Limited memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS algorithm with the greedy diffusion search (GDS algorithm, is incorporated to solve the minimization problem of energy consumption and predict the system’s optimal set-points under quasi-steady-state conditions. The integrated simulation tool is validated against experimental data. The results obtained demonstrate the proposed operation strategy is reliable, and can save energy by 20.8% as compared to an uncontrolled system under certain testing conditions.

  9. Structural evaluation of IEA-R1 primary system pump nozzles

    Energy Technology Data Exchange (ETDEWEB)

    Fainer, Gerson; Faloppa, Altair A.; Oliveira, Carlos A. de; Mattar Neto, Miguel, E-mail: gfainer@ipen.br, E-mail: afaloppa@ipen.br, E-mail: calberto@ipen.br, E-mail: mmattar@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    The IEA-R1 pumps of the primary coolant system may be required to withstand design and operational conditions. IEA-R1 nuclear research reactor is an open pool type reactor operated by IPEN since 1957. The reactor can be operated up to 5MW heating power since it was upgraded in a modernization program conducted by IPEN. The primary coolant system is composed by the piping system, decay tank, two heat pumps and two heat exchangers. In the latest arrangement upgrade of the primary system, conducted in 2014 as part of an aging management program, a partial replacement of the coolant piping and total replacement of piping and pump supports were done. As consequence, reviewed loads in the pump nozzles were obtained demanding a new evaluation of them. The aim of this report is to present the structural evaluation of the pump nozzles, considering the new loads coming from the new piping layout, according to: API 610 code verification, Supplier loads and structural analysis applying finite element method, by using the ANSYS computer program, regarding ASME VIII Div 1 & 2 recommendations. (author)

  10. Theoretical energy and exergy analyses of solar assisted heat pump space heating system

    Directory of Open Access Journals (Sweden)

    Atmaca Ibrahim

    2014-01-01

    Full Text Available Due to use of alternative energy sources and energy efficient operation, heat pumps come into prominence in recent years. Especially in solar-assisted heat pumps, sizing the required system is difficult and arduous task in order to provide optimum working conditions. Therefore, in this study solar assisted indirect expanded heat pump space heating system is simulated and the results of the simulation are compared with available experimental data in the literature in order to present reliability of the model. Solar radiation values in the selected region are estimated with the simulation. The case study is applied and simulation results are given for Antalya, Turkey. Collector type and storage tank capacity effects on the consumed power of the compressor, COP of the heat pump and the overall system are estimated with the simulation, depending on the radiation data, collector surface area and the heating capacity of the space. Exergy analysis is also performed with the simulation and irreversibility, improvement potentials and exergy efficiencies of the heat pump and system components are estimated.

  11. PRINCIPLES OF DEVELOPMENT MATHEMATICAL MODEL FOR RESEARCHING OF NONPULSATILE FLOW PUMP AND CARDIAC SYSTEM

    Directory of Open Access Journals (Sweden)

    I. V. Bykov

    2013-01-01

    Full Text Available Aim. The presented research uncovers the using of mathematical modeling methods for cardio-vascular system and axial blood pump interaction analysis under heart failure with combined valve pathology. The research will pro- vide data for automated pump control algorithm synthesis. Materials and methods. Mathematical model is build up by using experiments results from mock cardio-vascular circulation loop and mathematical representation of Newtonian fluid dynamics in pulsing circulation loop. The model implemented in modeling environment Simulink (Matlab. Results. Authors implemented mathematical model which describe cardio-vascular system and left-ven- tricular assistive device interaction for intact conditions. Values of parameters for intact conditions were acquired in the experiments on animals with implanted axial pump, experiments were conducted in FRCTAO. The model was verified by comparison of instantaneous blood flowrate values in experiments and in model. Conclusion. The paper present implemented mathematical model of cardio-vascular system and axial pump interaction for intact conditions, where the pump connected between left ventricle and aorta. In the next part of research authors will use the presented model to evaluate using the biotechnical system in conditions of heart failure and valve pathology. 

  12. Energy efficient pump couplings in HVAC systems; Energirigtige pumpekoblinger i HVAC systemer

    Energy Technology Data Exchange (ETDEWEB)

    Svendsen, Peter; Andersen, Hans

    2004-12-01

    This report presents results form the pre-project: Energy efficient pump couplings in HVAC systems. The pre-project has shown that there is no barrier as regards construction preventing the use of variable flow in the surfaces. The theoretical saving potential can be can be realized of the order of approximately 50 %. For the heating surfaces alone the power saving potential by 100 % implementation of the principle in Denmark will be of the order of 100 GWh. Add to this a cooling saving potential and several diverted potentials. (BA)

  13. Nano-porous-water Absorbents for Solid-absorbebt Heat Pump System

    Science.gov (United States)

    Mizota, Tadato; Nakayama, Noriaki

    Zeolite-water heat-pump system has been developed in these 25 years. Recently, an instant beer-cooling system has appeared by using the zeolite heat pump system as a commercial product. It takes so long time for the development since the first proposal. The most serious problem through the development has been of the ability of absorbents. Themaximum heat exchange capacity to date exceeds 1MJ•kg-1 for Mg89-A, which is comparable to the energy storage capacity of modern alkaline-ion batteries in weight-bases. But it needs high temperature heat sources more than 200°C for the activation. Absorbents useful at lower temperatures are thus desirable for effective use of various kinds of lower temperature heat sources Various nano-porous materials as well as zeolites now under investigation as candidates of heat-pump absorbents, such as silica-gels, allophane, imogolite, hydrotalcite, etc.

  14. Study Of Solar PV Sizing Of Water Pumping System For Irrigation Of Asparagus

    Directory of Open Access Journals (Sweden)

    Mya Su Kyi

    2015-08-01

    Full Text Available The motivation for this system come from the countries where economy is depended on agriculture and the climatic conditions lead to lack of rains. The farmers working in the farm lands are dependent on the rains and bore wells. Even if the farm land has a water-pump manual involvement by farmers is required to turn the pump onoff when on earth needed. This paper presents design and calculation analysis of efficient Solar PV water pumping system for irrigation of Asparagus. The study area falls 21-58-30 N Latitude and 96-5-0 E Longitude of Mandalay. The PV system sizing was made in such a way that it was capable of irrigation one acre of Asparagus plot with a daily water requirement of 25mday.

  15. The potential hidden hazards of a laser pumped tunable OPO system.

    Science.gov (United States)

    McPherson, Nicole A; Neal, Thomas A; Johnson, Thomas E

    2008-11-01

    Laser pumped tunable optical parametric oscillator (OPO) systems from 1,300 to 2,200 nm have been introduced due to their retina-safe characteristics and ability to adjust to multiple wavelengths. We report on unintended consequences to a rabbit cornea resulting from OPO exposure. No gross injury was visible to the cornea post exposure; however, closer examination revealed a vitreous hemorrhage had occurred within the eye. Evaluation of the tunable laser system revealed a cracked crystal and a resultant 1,064 nm emission from the pump laser, rather than the desired 1,540 nm wavelength. This incident illustrates the importance of protective eyewear shielding against all potential wavelengths, including the pump lasers, when operating OPO tunable laser systems.

  16. Vapor Compression and Thermoelectric Heat Pump Heat Exchangers for a Condensate Distillation System: Design and Experiment

    Science.gov (United States)

    Erickson, Lisa R.; Ungar, Eugene K.

    2013-01-01

    Maximizing the reuse of wastewater while minimizing the use of consumables is critical in long duration space exploration. One of the more promising methods of reclaiming urine is the distillation/condensation process used in the cascade distillation system (CDS). This system accepts a mixture of urine and toxic stabilizing agents, heats it to vaporize the water and condenses and cools the resulting water vapor. The CDS wastewater flow requires heating and its condensate flow requires cooling. Performing the heating and cooling processes separately requires two separate units, each of which would require large amounts of electrical power. By heating the wastewater and cooling the condensate in a single heat pump unit, mass, volume, and power efficiencies can be obtained. The present work describes and compares two competing heat pump methodologies that meet the needs of the CDS: 1) a series of mini compressor vapor compression cycles and 2) a thermoelectric heat exchanger. In the paper, the system level requirements are outlined, the designs of the two heat pumps are described in detail, and the results of heat pump performance tests are provided. A summary is provided of the heat pump mass, volume and power trades and a selection recommendation is made.

  17. Counter-rotating type axial flow pump unit in turbine mode for micro grid system

    Science.gov (United States)

    Kasahara, R.; Takano, G.; Murakami, T.; Kanemoto, T.; Komaki, K.

    2012-11-01

    Traditional type pumped storage system contributes to adjust the electric power unbalance between day and night, in general. This serial research proposes the hybrid power system combined the wind power unit with the pump-turbine unit, to provide the constant output for the grid system, even at the suddenly fluctuating/turbulent wind. In the pumping mode, the pump should operate unsteadily at not only the normal but also the partial discharge. The operation may be unstable in the rising portion of the head characteristics at the lower discharge, and/or bring the cavitation at the low suction head. To simultaneously overcome both weak points, the authors have proposed a superior pump unit that is composed of counter-rotating type impellers and a peculiar motor with double rotational armatures. This paper discusses the operation at the turbine mode of the above unit. It is concluded with the numerical simulations that this type unit can be also operated acceptably at the turbine mode, because the unit works so as to coincide the angular momentum change through the front runners/impellers with that thorough the rear runners/impellers, namely to take the axial flow at not only the inlet but also the outlet without the guide vanes.

  18. A novel subcutaneous infusion delivery system based on osmotic pump: in vitro and in vivo evaluation.

    Science.gov (United States)

    Gong, Wei; Ma, Rui; Mei, Danyu; Jing, Pei; Dong, Xiao; Li, Bingsheng; Yang, Yanfang; Du, Lina; Mei, Xing-Guo; Hu, Fu-Qiang

    2014-02-01

    An economical, convenient portable drug delivery system combining osmotic pump with subcutaneous infusion was developed, which was composed of three primary components: water chamber, osmotic pump chamber and support base. Ceftriaxone sodium (CRO) was selected as the model drug and osmotic pump tablets were prepared. The influence of osmotic agents on drug release profiles was evaluated. As the adjustment made by the osmotic agents was limited, the compositions of semipermeable membrane were investigated to determine significant associations of factors based on orthogonal design. The in vitro release profiles of the optimum formulation achieved to the predetermined value (15 ± 3 min for the initial release time T(i) and 5.75 ± 0.25 h for the extent release time T(e)). The pharmacokinetic profiles of this drug delivery system were evaluated in Beagle dogs. In vivo results demonstrated that the osmotic pump subcutaneous infusion administration was equivalent to intravenous injection administration in terms of bioavailability. Moreover, constant drug plasma levels with minimized fluctuations could be achieved with this osmotic pump subcutaneous infusion system, compared with intravenous injection.

  19. Optimization of hybrid system (wind-solar energy) for pumping water

    African Journals Online (AJOL)

    DR OKE

    The hybrid generator is constituted of a wind generator and photovoltaic field. To be able to transform the hybrid energy into electricity and exploit the Moto-pump, it is necessary to arrange an energizing system that ensures the conversion of energy. The command system ensures the control of the different components.

  20. Molecular dynamics simulations of valveless pumping in a closed microfluidic tube-system

    DEFF Research Database (Denmark)

    Hansen, J.S.; Ottesen, Johnny T.; Lemarchard, A.

    2005-01-01

    In this paper we study the flow which is generated by a valveless pumping mechanism in a closed tube-system consistent of two tubes with different radii. This remarkable system has been investigated by Ottesen [J. T. Ottesen, J. Math. Biol. 46(2003) 309-332] on a macroscopic level and we find...

  1. Energy dashboard for real-time evaluation of a heat pump assisted solar thermal system

    Science.gov (United States)

    Lotz, David Allen

    The emergence of net-zero energy buildings, buildings that generate at least as much energy as they consume, has lead to greater use of renewable energy sources such as solar thermal energy. One example is a heat pump assisted solar thermal system, which uses solar thermal collectors with an electrical heat pump backup to supply space heating and domestic hot water. The complexity of such a system can be somewhat problematic for monitoring and maintaining a high level of performance. Therefore, an energy dashboard was developed to provide comprehensive and user friendly performance metrics for a solar heat pump system. Once developed, the energy dashboard was tested over a two-week period in order to determine the functionality of the dashboard program as well as the performance of the heating system itself. The results showed the importance of a user friendly display and how each metric could be used to better maintain and evaluate an energy system. In particular, Energy Factor (EF), which is the ratio of output energy (collected energy) to input energy (consumed energy), was a key metric for summarizing the performance of the heating system. Furthermore, the average EF of the solar heat pump system was 2.29, indicating an efficiency significantly higher than traditional electrical heating systems.

  2. High efficient ammonia heat pump system for industrial process water using the ISEC concept. Part 1

    DEFF Research Database (Denmark)

    Rothuizen, Erasmus Damgaard; Madsen, C.; Elmegaard, Brian

    2014-01-01

    The purpose of the Isolated System Energy Charging (ISEC) is to provide a high-efficient ammonia heat pump system for hot water production. The ISEC concept uses two storage tanks for the water, one discharged and one charged. The charged tank is used for the industrial process while the discharg...

  3. Analysis of off-grid hybrid wind turbine/solar PV water pumping systems

    Science.gov (United States)

    While many remote water pumping systems exist (e.g. mechanical windmills, solar photovoltaic , wind-electric, diesel powered), very few combine both the wind and solar energy resources to possibly improve the reliability and the performance of the system. In this paper, off-grid wind turbine (WT) a...

  4. Experimental analysis on performance of high temperature heat pump and desiccant wheel system

    DEFF Research Database (Denmark)

    Sheng, Ying; Zhang, Yufeng; Deng, Na

    2013-01-01

    In order to solve the problem of high energy consumption for regeneration of desiccant wheel in the rotary desiccant system, high temperature heat pump and desiccant wheel (HTHP&DW) system and corresponding air conditioning unit is built and tested in the extensive thermal hygrometric environment...

  5. Intensity Noise Transfer Through a Diode-pumped Titanium Sapphire Laser System

    DEFF Research Database (Denmark)

    Tawfieq, Mahmoud; Hansen, Anders Kragh; Jensen, Ole Bjarlin

    2017-01-01

    In this paper, we investigate the noise performance and transfer in a titanium sapphire (Ti:S) laser system. This system consists of a DBR tapered diode laser, which is frequency doubled in two cascaded nonlinear crystals and used to pump the Ti:S laser oscillator. This investigation includes...

  6. Numerical simulation of the power characteristics of twin-core pulse reactor-pumped laser system

    Science.gov (United States)

    Gulevich, A. V.; Barzilov, A. P.; Dyachenko, P. P.; Zrodnikov, A. V.; Kukharchuk, O. F.; Kachanov, B. V.; Kolyada, S. G.; Pashin, E. A.

    1996-05-01

    Concept for high-power pulsed reactor-pumped laser system (RPLS) based on the new physical principles (direct nuclear-to-optical conversion) is discussed with reference to ICF feasibility problem. Theoretical problems for substantiation of the neutronic and physical characteristics of the RPLS power model are considered. Results of numerical studies of the expected power characteristics of reactor laser system are discussed.

  7. Optimization of hybrid system (wind-solar energy) for pumping water ...

    African Journals Online (AJOL)

    This paper presents an optimization method for a hybrid (wind-solar) autonomous system designed for pumping water. This method is based on mathematical models demonstrated for the analysis and control of the performance of the various components of the hybrid system. These models provide an estimate of ...

  8. Electric power conservation while using pumping systems; Conservacion de Energia Electrica en Sistemas de Bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Nambiar, P

    2007-01-15

    The pumping systems provide about 20 to 25 percent of energy which is necessary worldwide: it is fruitful to understand how to use electric power efficiently, to achieve the reduction regarding expenses a pumping system implies.It is essential to possess a better knowledge about the pumping system and its applications, in order to be able to use energy responsibly. If people do not how to operate this kind of systems properly, they will use inadequate equipment that will cause an energy waste. In addition it is important to know: alternative methods to meet variable demands, an adapted system to pump water requirements in order to ensure the pump work in its pumping point, and the life cycle system cost for the energy saving in the long term. [Spanish] En promedio del 20 al 25% de la energia necesaria en el mundo proviene de los sistemas de bombeo, por tal razon es importante saber como utilizar la energia electrica con eficiencia para asi lograr reducir los gastos que este tipo de sistemas implican. Para poder hacer un buen uso de la energia, es necesario que se tenga un conocimiento mayor del sistema de bombeo y aplicacion, ya que la ignorancia sobre esto exige el uso de aparatos que contribuyen al desperdicio de la energia; por otro lado tambien es esencial conocer metodos alternos para demandas variables, tener un sistema que se adapte a las necesidades de bombeo del agua para asegurarse de que cada bomba trabaje cerca de su punto de bombeo y finalmente conocer el costo del ciclo de vida del sistema para el ahorro de energia a largo plazo.

  9. Optimization of solar assisted heat pump systems via a simple analytic approach

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J W

    1980-01-01

    An analytic method for calculating the optimum operating temperature of the collector/storage subsystem in a solar assisted heat pump is presented. A tradeoff exists between rising heat pump coefficient of performance and falling collector efficiency as this temperature is increased, resulting in an optimum temperature whose value increases with increasing efficiency of the auxiliary energy source. Electric resistance is shown to be a poor backup to such systems. A number of options for thermally coupling the system to the ground are analyzed and compared.

  10. Solar Colletors Combined with Ground-Source Heat Pumps in Dwellings - Analyses of System Performance

    OpenAIRE

    Kjellsson, Elisabeth

    2009-01-01

    The use of ground-source heat pumps for heating buildings and domestic hot water in dwellings is increasing rapidly in Sweden. The heat pump extracts heat from the ground by a U-pipe in a vertical borehole. In order to reduce the electricity demand in the system, the combination with solar collectors is introduced. This system may be designed in many ways and the advantages differ a lot. Solar heat can also be used for recharging of boreholes when neighbouring boreholes are thermally influenc...

  11. Evaluation of the performance in the solar assisted heat pump system; Taiyonetsu riyo heat pump system no seino hyoka ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Y. [Osaka Institute of Technology, Osaka (Japan)

    1996-10-27

    Performance of a solar heating system with a hydrothermal source heat pump was evaluated and compared with that of a direct solar heating system. The sun-dependency rates ({Sigma}D and {Sigma}H)of the direct system and heat pump (HP)-provided system were expressed as a function of the rate ({alpha}) of the auxiliary heat against the collected heat and as a function of the performance coefficient and {alpha}, respectively. When the sun-dependency rates are compared, it is found that the HP-provided system is the more advantageous when {Sigma}H/{Sigma}D>1. The relationship between the {alpha}`s of the two systems was clarified and computation was performed to compare the sun-dependency rates on condition that the two are equal in the heat collecting area. Although the sun-dependence rate cannot be elevated to 100% in the HP-provided system, it achieves a sun-dependency rate higher than that of the direct system even when the heat collecting area is small. In cases where the building is economically limited, for instance, with respect to the area for solar collector installation, it is advantageous to employ the HP-provided system. 5 figs., 1 tab.

  12. A Multi-Pumping Flow System for In Situ Measurements of Dissolved Manganese in Aquatic Systems

    Directory of Open Access Journals (Sweden)

    David Meyer

    2016-11-01

    Full Text Available A METals In Situ analyzer (METIS has been used to determine dissolved manganese (II concentrations in the subhalocline waters of the Gotland Deep (central Baltic Sea. High-resolution in situ measurements of total dissolved Mn were obtained in near real-time by spectrophotometry using 1-(2-pyridylazo-2-naphthol (PAN. PAN is a complexing agent of dissolved Mn and forms a wine-red complex with a maximum absorbance at a wavelength of 562 nm. Results are presented together with ancillary temperature, salinity, and dissolved O 2 data. Lab calibration of the analyzer was performed in a pressure testing tank. A detection limit of 77 nM was obtained. For validation purposes, discrete water samples were taken by using a pump-CTD system. Dissolved Mn in these samples was determined by an independent laboratory based method (inductively coupled plasma–optical emission spectrometry, ICP-OES. Mn measurements from both METIS and ICP-OES analysis were in good agreement. The results showed that the in situ analysis of dissolved Mn is a powerful technique reducing dependencies on heavy and expensive equipment (pump-CTD system, ICP-OES and is also cost and time effective.

  13. Multi-pumping flow system for the spectrophotometric determination of dipyrone in pharmaceutical preparations.

    Science.gov (United States)

    Lima, José L F C; Oliveira Sá, Sandra M; Santos, João L M; Zagatto, Elias A G

    2003-08-08

    A novel flow system for the spectrophotometric determination of dipyrone with p-dimethylaminobenzaldehyde exploiting the multi-pumping approach was developed. The proposed methodology utilises several micro-pumps for propelling the involved fluids under improved mixing conditions, introducing sample/reagent aliquots and providing commuting facilities. As a consequence the multi-pumping system presents high versatility and manifold simplicity, as well as a straightforward operational control and enhanced analytical capabilities. Linearity of the analytical curve was observed within 10 and 400 mg l(-1) dipyrone (r=0.9997; n=6), results were precise (r.s.d.<0.12%; n=20) and sampling rate was 50 h(-1). Detection limit was estimated as 1 mg l(-1) dipyrone. The method was applied to pharmaceutical preparations and the results were in agreement with those obtained by the reference procedure with relative deviations within -1.7 and +2.2%.

  14. Hydride heat pump. Volume I. Users manual for HYCSOS system design program. [HYCSOS code

    Energy Technology Data Exchange (ETDEWEB)

    Gorman, R.; Moritz, P.

    1978-05-01

    A method for the design and costing of a metal hydride heat pump for residential use and a computer program, HYCSOS, which automates that method are described. The system analyzed is one in which a metal hydride heat pump can provide space heating and space cooling powered by energy from solar collectors and electric power generated from solar energy. The principles and basic design of the system are presented, and the computer program is described giving detailed design and performance equations used in the program. The operation of the program is explained, and a sample run is presented. This computer program is part of an effort to design, cost, and evaluate a hydride heat pump for residential use. The computer program is written in standard Fortran IV and was run on a CDC Cyber 74 and Cyber 174 computer. A listing of the program is included as an appendix. This report is Volume 1 of a two-volume document.

  15. Commercial Refrigeration: Heat Transfer Optimization and Energy Reduction, Measurement and Verification of a Liquid Refrigerant Pump System Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Gaul, Chris [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sheppy, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-03-22

    This study describes the test results of a Refrigerant Pump System integrated into a commercial supermarket direct expansion (DX) vapor compression refrigeration system. The Liquid Refrigerant Pump System retrofit (patent-pending; application number 13/964,198) was introduced to NREL in August 2014 by CTA Architects Engineers.

  16. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  17. Theoretical study of heat pump system using CO2/dimethylether as refrigerant

    Directory of Open Access Journals (Sweden)

    Fan Xiao-Wei

    2013-01-01

    Full Text Available Nowadays, HCFC22 is widely used in heat pump systems in China, which should be phased out in the future. Thus, eco-friendly mixture CO2/dimethylether is proposed to replace HCFC22. Compared with pure CO2 and pure dimethylether, the mixture can reduce the heat rejection pressure, and suppress the flammability and explosivity of pure dimethylether. According to the Chinese National Standards on heat pump water heater and space heating system, performances of the subcritical heat pump system are discussed and compared with those of the HCFC22 system. It can be concluded that CO2 /dimethylether mixture works efficiently as a refrigerant for heat pumps with a large heat-sink temperature rise. When mass fraction of dimethylether is increased, the heat rejection pressure is reduced. Under the nominal working condition, there is an optimal mixture mass fraction of 28/72 of CO2/dimethylether for water heater application under conventional condensation pressure, 3/97 for space heating application. For water heater application, both the heating coefficient of performance and volumetric heating capacity increase by 17.90% and 2.74%, respectively, compared with those of HCFC22 systems. For space heating application, the heating coefficient of performance increases by 8.44% while volumetric heating capacity decreases by 34.76%, compared with those of HCFC22 systems. As the superheat degree increases, both the heating coefficient of performance and volumetric heating capacity tend to decrease.

  18. Lethbridge wind research test site evaluation of wind and solar pumping systems, 1985 - 1987

    Energy Technology Data Exchange (ETDEWEB)

    Paterson, B.A. (Land Evaluation and Reclamation Branch, Alberta Agriculture, Lethbridge, AB (Canada)); Baker, D.R. (DRB Engineering Consultants Ltd., Calgary, AB (Canada)); Jensen, N.E. (Jensen Engineerging Ltd., Olds, AB (Canada))

    1988-01-01

    The performance of wind pumping systems has been evaluated over the past 3 years at a field test facility in Alberta. A total of eight wind turbines (6 mechanical and 2 electromechanical) and 2 photovoltaic-powered pumpers were tested. Data are presented on each machine's availability and reliability. Performance curves (pumping rate versus wind speed) are included. The data format is based on the International Enegry Agency's wind performance testing standard, so that extrapolation of the information world-wide is possible. The test procedures and the data acquisition and monitoring systems are also described. In addition, the applications and markets for wind pumps, notably in agriculture (land drainage, irrigation, livestock watering), are discussed. The results of the testing have been encouraging. Long-term reliability is a key factor which needs improvement, and which has been seen to be of much greater importance than overall performance numbers or improvements. The availability of water pumping systems tested at the site ranges from a low of 24% to a high of 100%. The test program has shown that full measurement of the overall availability and reliability of a machine requires that it be monitored at least 2-3 years. Most of the machines at the site have not met this requirement because of continuous changes and upgrading by the manufacturers, who are responsible for installation and maintenance of the wind turbine units. The exceptions to this are the 2 solar pumping systems, which have performed very reliably over the last 3 years, with very low maintenance requirements. Their disadvantage at present is a higher capital cost per unit of water pumped compared with the wind turbines. 43 figs., 2 tabs.

  19. Investigation on CO2 Ground-coupled Heat Pumping System with Ejector

    OpenAIRE

    Morshed, Monjur

    2015-01-01

    After the proposal of CO2 transcritical cycle in 1980s by Professor Gustav Lorentz, researchers have looked into theoretical and experimental research, as well as commercial system development to improve transcritical system performance to a level similar to that of conventional heat pump systems. Over the years researchers are investigating for newer system concepts with transcritical CO2 cycle that can be implemented across the globe for different climate conditions. One of the major challe...

  20. Research on the System of Pulse Synthesis Pre-pump Rayleigh BOTDA technology

    Directory of Open Access Journals (Sweden)

    Shang Qiufeng

    2015-01-01

    Full Text Available The conventional Rayleigh scattering Brillouin Optical Time Domain Analysis (Rayleigh BOTDA system adopted the leakage light ahead of the pump pulse to generate Rayleigh back-scattering light. Stimulated Brillouin scattering (SBS interacts between an optical pulse and a Rayleigh back-scattering light, then the temperature and strain information of the optical fiber are perceived by measuring the Rayleigh scattering light. However, the width of pulse is inversely proportional to the accuracy of spectrum detection, which means the narrower the pulse, the wider the Brillouin spectrum. But the spatial resolution is strictly related to the duration of the optical pulse, when the pulse width is less than the phonon lifetime, the Brillouin spectrum width is much larger than the Brillouin natural gain spectrum width. The spectrum detection accuracy of the system can be effectively improved by adding a pre-pump ahead of the pump pulse to stimulate the acoustic wave field in the Rayleigh BOTDA system. In this paper, we present a new method of synthesizing step pulse. Through the OpiSystem software simulation and Matlab software simulation, the influence of the pre-pump width and power on the performance of the system is analyzed and the feasibility of this method is confirmed by preliminary experiment.

  1. Application of fuzzy adaptive control to a MIMO nonlinear time-delay pump-valve system.

    Science.gov (United States)

    Lai, Zhounian; Wu, Peng; Wu, Dazhuan

    2015-07-01

    In this paper, a control strategy to balance the reliability against efficiency is introduced to overcome the common off-design operation problem in pump-valve systems. The pump-valve system is a nonlinear multi-input-multi-output (MIMO) system with time delays which cannot be accurately measured but can be approximately modeled using Bernoulli Principle. A fuzzy adaptive controller is applied to approximate system parameters and achieve the control of delay-free model since the system model is inaccurate and the direct feedback linearization method cannot be applied. An extended Smith predictor is introduced to compensate time delays of the system using the inaccurate system model. The experiment is carried out to verify the effectiveness of the control strategy whose results show that the control performance is well achieved. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  2. Technoeconomical Assessment of Optimum Design for Photovoltaic Water Pumping System for Rural Area in Oman

    Directory of Open Access Journals (Sweden)

    Hussein A. Kazem

    2015-01-01

    Full Text Available Photovoltaic (PV systems have been used globally for a long time to supply electricity for water pumping system for irrigation. System cost drops down with time since PV technology, efficiency, and design methodology have been improved and cost of wattage drops dramatically in the last decade. In the present paper optimum PV system design for water pumping system has been proposed for Oman. Intuitive and numerical methods were used to design the system. HOMER software as a numerical method was used to design the system to come up with optimum design for Oman. Also, REPS.OM software has been used to find the optimum design based on hourly meteorological data. The daily solar energy in Sohar was found to be 6.182 kWh/m2·day. However, it is found that the system annual yield factor is 2024.66 kWh/kWp. Furthermore, the capacity factor was found to be 23.05%, which is promising. The cost of energy and system capital cost has been compared with that of diesel generator and systems in literature. The comparison shows that the cost of energy is 0.180, 0.309, and 0.790 USD/kWh for PV-REPS.OM, PV-HOMER, and diesel systems, respectively, which sound that PV water pumping systems are promising in Oman.

  3. Parametric pitch instability investigation of Deep Draft Semi-submersible platform in irregular waves

    OpenAIRE

    Huan Mao; Hezhen Yang

    2016-01-01

    Parametric pitch instability of a Deep Draft Semi-submersible platform (DDS) is investigated in irregular waves. Parametric pitch is a form of parametric instability, which occurs when parameters of a system vary with time and the variation satisfies a certain condition. In previous studies, analyzing of parametric instability is mainly limited to regular waves, whereas the realistic sea conditions are irregular waves. Besides, parametric instability also occurs in irregular waves in some exp...

  4. A discussion of system reliability and the relative importance of pumps and valves to overall system availability

    Energy Technology Data Exchange (ETDEWEB)

    Poole, A.B. [Oak Ridge National Lab., TN (United States)

    1996-12-01

    An analysis was undertaken to establish preliminary trends for how component aging can effect failure rates for swing check valves, centrifugal pumps and motor operated valves. These failure rate trends were evaluated over time and linear aging rate models established. The failure rate models were then used with classic reliability theories to estimate reliability as a function of operating time. Reliability theory was also used to establish a simple system reliability model. Using the system model, the relative importance of pumps and valves to the overall system reliability were studied. Conclusions were established relative to overall system availability over time and the relative unavailabilities of the various components studied.

  5. Gauge freedom in observables and Landsberg's nonadiabatic geometric phase: Pumping spectroscopy of interacting open quantum systems

    Science.gov (United States)

    Pluecker, T.; Wegewijs, M. R.; Splettstoesser, J.

    2017-04-01

    We set up a general density-operator approach to geometric steady-state pumping through slowly driven open quantum systems. This approach applies to strongly interacting systems that are weakly coupled to multiple reservoirs at high temperature, illustrated by an Anderson quantum dot. Pumping gives rise to a nonadiabatic geometric phase that can be described by a framework originally developed for classical dissipative systems by Landsberg. This geometric phase is accumulated by the transported observable (charge, spin, energy) and not by the quantum state. It thus differs radically from the adiabatic Berry-Simon phase, even when generalizing it to mixed states, following Sarandy and Lidar. As a key feature, our geometric formulation of pumping stays close to a direct physical intuition (i) by tying gauge transformations to calibration of the meter registering the transported observable and (ii) by deriving a geometric connection from a driving-frequency expansion of the current. Furthermore, our approach provides a systematic and efficient way to compute the geometric pumping of various observables, including charge, spin, energy, and heat. These insights seem to be generalizable beyond the present paper's working assumptions (e.g., Born-Markov limit) to more general open-system evolutions involving memory and strong-coupling effects due to low-temperature reservoirs as well. Our geometric curvature formula reveals a general experimental scheme for performing geometric transport spectroscopy that enhances standard nonlinear spectroscopies based on measurements for static parameters. We indicate measurement strategies for separating the useful geometric pumping contribution to transport from nongeometric effects. A large part of the paper is devoted to an explicit comparison with the Sinitsyn-Nemenmann full-counting-statistics (FCS) approach to geometric pumping, restricting attention to the first moments of the pumped observable. Covering all key aspects, gauge

  6. Note: Development of a compact electromagnetic hydraulic pump for a microrobot joint driving system

    Science.gov (United States)

    Chen, Naijian; Wang, Sun'an; Zhang, Jinhua

    2010-04-01

    This note describes a compact electromagnetic hydraulic pump (EMHP) designed primarily to build a microdriving system for a robot joint actuator. A characteristic mathematical model integrating electricity, magnetism, and hydraulics is constructed to represent the working process of the EMHP. Tests show that a volumetric flow rate of up to 430 cm3/min and load pressure of up to 2.5 MPa can be achieved. The prototype pump can supply stable pressure of 0˜2.4 MPa and acceleration of 1.2 MPa/s for the robot joint actuator.

  7. Economic valuation of heat pumps and electric boilers in the Danish energy system

    DEFF Research Database (Denmark)

    Nielsen, Maria Grønnegaard; Morales González, Juan Miguel; Zugno, Marco

    2016-01-01

    Heat pumps (HP) and electric immersion boilers (EB) have great potential to increase flexibility in energy systems. In parallel, decreasing taxes on electricity-based heat production are creating a more favorable economic environment for the deployment of these units in Denmark. In this paper...... to investigate the effect on market performance of varying capacity and efficiency for these units, as well as of different levels of prices in the electricity market. We find that these parameters substantially affect the profitability of heat pumps and electric boilers, hence, they must be carefully assessed...

  8. Photovoltaic pumping system - Comparative study analysis between direct and indirect coupling mode

    Science.gov (United States)

    Harrag, Abdelghani; Titraoui, Abdessalem; Bahri, Hamza; Messalti, Sabir

    2017-02-01

    In this paper, P&O algorithm is used in order to improve the performance of photovoltaic water pumping system in both dynamic and static response. The efficiency of the proposed algorithm has been studied successfully using a DC motor-pump powered using controller by thirty six PV modules via DC-DC boost converter derived by a P&O MPPT algorithm. Comparative study results between the direct and indirect modes coupling confirm that the proposed algorithm can effectively improve simultaneously: accuracy, rapidity, ripple and overshoot.

  9. Variable Displacement Control of the Concrete Pumping System Based on Dynamic Programming

    Directory of Open Access Journals (Sweden)

    Ye Min

    2017-01-01

    Full Text Available To solve the problems of cylinder piston striking cylinder and the hydraulic shocking of the main pump, and causing energy waste problem, the method of variable displacement control of piston stroke was proposed. In order to achieve effective control of the piston stroke, variable displacement control model was established under the physical constraint condition of non-collision between piston and cylinder. And the control process was realized by Dynamic Programming(DP, the simulation and test results show that piston of concrete pumping system don’t strike cylinder and reduce the hydraulic shock of the main pump outlet, meanwhile improve the response speed of the cylinder and achieve energy-saving purposes under varying loads. This control model built in the integration design space of structure variable and control variable is of guiding significance for solving open-loop system’s engineering problems.

  10. The role of heat pump technologies in the design of future sustainable energy systems

    DEFF Research Database (Denmark)

    Blarke, Morten Boje; Lund, Henrik

    2005-01-01

    In this paper, it is shown that in support of its ability to improve the overall economic cost-effectiveness and flexibility of the Danish energy system, the financially feasible integration of large-scale heat pumps with existing CHP units, is critically sensitive to the operational mode...... of the heat pump vis-à-vis the operational coefficient of performance (COP), which is set by the temperature level of the heat source. When using only ambient air as the heat source, the total heat production costs increases by about 10%, while the partial use of condensed flue gas from the CHP unit as a heat...... source results in an 8% cost reduction. Furthermore, the operational analysis shows that when a large-scale heat pump is integrated with an existing CHP unit, the projected spot market situation in Nord Pool, which reflects a growing share of wind power and heat-bound power generation electricity...

  11. Modeling of an Air Conditioning System with Geothermal Heat Pump for a Residential Building

    Directory of Open Access Journals (Sweden)

    Silvia Cocchi

    2013-01-01

    Full Text Available The need to address climate change caused by greenhouse gas emissions attaches great importance to research aimed at using renewable energy. Geothermal energy is an interesting alternative concerning the production of energy for air conditioning of buildings (heating and cooling, through the use of geothermal heat pumps. In this work a model has been developed in order to simulate an air conditioning system with geothermal heat pump. A ground source heat pump (GSHP uses the shallow ground as a source of heat, thus taking advantage of its seasonally moderate temperatures. GSHP must be coupled with geothermal exchangers. The model leads to design optimization of geothermal heat exchangers and to verify the operation of the geothermal plant.

  12. Quantum behaviour of pumped and damped triangular Bose-Hubbard systems

    Science.gov (United States)

    Chianca, C. V.; Olsen, M. K.

    2017-12-01

    We propose and analyse analogs of optical cavities for atoms using three-well Bose-Hubbard models with pumping and losses. We consider triangular configurations. With one well pumped and one damped, we find that both the mean-field dynamics and the quantum statistics show a quantitative dependence on the choice of damped well. The systems we analyse remain far from equilibrium, preserving good coherence between the wells in the steady-state. We find quadrature squeezing and mode entanglement for some parameter regimes and demonstrate that the trimer with pumping and damping at the same well is the stronger option for producing non-classical states. Due to recent experimental advances, it should be possible to demonstrate the effects we investigate and predict.

  13. Designing an enhanced groundwater sample collection system

    Energy Technology Data Exchange (ETDEWEB)

    Schalla, R.

    1994-10-01

    As part of an ongoing technical support mission to achieve excellence and efficiency in environmental restoration activities at the Laboratory for Energy and Health-Related Research (LEHR), Pacific Northwest Laboratory (PNL) provided guidance on the design and construction of monitoring wells and identified the most suitable type of groundwater sampling pump and accessories for monitoring wells. The goal was to utilize a monitoring well design that would allow for hydrologic testing and reduce turbidity to minimize the impact of sampling. The sampling results of the newly designed monitoring wells were clearly superior to those of the previously installed monitoring wells. The new wells exhibited reduced turbidity, in addition to improved access for instrumentation and hydrologic testing. The variable frequency submersible pump was selected as the best choice for obtaining groundwater samples. The literature references are listed at the end of this report. Despite some initial difficulties, the actual performance of the variable frequency, submersible pump and its accessories was effective in reducing sampling time and labor costs, and its ease of use was preferred over the previously used bladder pumps. The surface seals system, called the Dedicator, proved to be useful accessory to prevent surface contamination while providing easy access for water-level measurements and for connecting the pump. Cost savings resulted from the use of the pre-production pumps (beta units) donated by the manufacturer for the demonstration. However, larger savings resulted from shortened field time due to the ease in using the submersible pumps and the surface seal access system. Proper deployment of the monitoring wells also resulted in cost savings and ensured representative samples.

  14. Operational test for photovoltaic pumping systems; Procedimento para averiguacao operacional de sistemas fotovoltaicos de bombeamento

    Energy Technology Data Exchange (ETDEWEB)

    Fedrizzi, Maria Cristina; Brito, Alaan Ubaiara; Zilles, Roberto [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Eletrotecnica e Energia. Lab. de Sistemas Fotovoltaicos], e-mail: fedrizzi@iee.usp.br, e-mail: alaan@iee.usp.br, e-mail: zilles@iee.usp.br

    2004-07-01

    This paper presents an operational test for photovoltaic pumping systems daily production, m{sup 3}/dia. The procedure does not involve expensive instrumentation and is easy to be applied in the field as acceptance and qualification tools. In this way, the paper presents the boundary conditions for operational test accomplishment that allows its application. (author)

  15. Renewable Energy Water Pumping Systems Handbook; Period of Performance: April 1--September 1, 2001

    Energy Technology Data Exchange (ETDEWEB)

    Argaw, N.

    2004-07-01

    Water is one of the most basic necessities of rural development. This book provides valuable information on how renewable energy technologies can be used for irrigation, livestock watering, and domestic water supplies. This report emphasizes wind and solar energy resources, and hybrid water pumping systems.

  16. Efficiency evaluation for the heat pump system in sharp continental climate

    Directory of Open Access Journals (Sweden)

    Maksimov Vyacheslav I.

    2017-01-01

    Full Text Available With the aim to calculate the energy efficient of water source heat pump system (HPSW under sharp climate conditions, the ice formation processe on the surface of evaporator pipes under conditions of “autumn-winter-spring” was studied.

  17. Simulation of Hybrid Photovoltaic Solar Assisted Loop Heat Pipe/Heat Pump System

    Directory of Open Access Journals (Sweden)

    Nannan Dai

    2017-02-01

    Full Text Available A hybrid photovoltaic solar assisted loop heat pipe/heat pump (PV-SALHP/HP water heater system has been developed and numerically studied. The system is the combination of loop heat pipe (LHP mode and heat pump (HP mode, and the two modes can be run separately or compositely according to the weather conditions. The performances of independent heat pump (HP mode and hybrid loop heat pipe/heat pump (LHP/HP mode were simulated and compared. Simulation results showed that on typical sunny days in spring or autumn, using LHP/HP mode could save 40.6% power consumption than HP mode. In addition, the optimal switchover from LHP mode to HP mode was analyzed in different weather conditions for energy saving and the all-year round operating performances of the system were also simulated. The simulation results showed that hybrid LHP/HP mode should be utilized to save electricity on sunny days from March to November and the system can rely on LHP mode alone without any power consumption in July and August. When solar radiation and ambient temperature are low in winter, HP mode should be used

  18. Comparative Study on Photovoltaic Pumping Systems Driven by Different Motors Optimized with Sliding Mode Control

    Directory of Open Access Journals (Sweden)

    Abdelhak Bouchakour

    2017-06-01

    Full Text Available This study investigates the performance of three different photovoltaic (PV water pumping systems driven by three types of motors, namely a separately excited DC motor (DCM, an asynchronous motor (ASM, and a permanent magnet synchronous motor (PMSM, via a DC/DC buck-boost converter coupled to a centrifugal pump. The purpose of this study is to implement a fast and robust control for this type of a nonlinear system, controlled by sliding mode (SM. This paper presents an SM control technique for controlling a DC/DC buck-boost converter to transfer the maximum power delivered by the PV generator. Each component is studied and analyzed to simulate the global system in MATLAB/SIMULINK. The three systems are then compared to determine the overall effectiveness of the proposed command. The study concludes that the ASM-driven PV system yields highly favorable results and requires less maintenance compared with other systems.

  19. Experimental study of R134a/R410A cascade cycle for variable refrigerant flow heat pump systems

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong Hun; Lee, Jae Wan; Park, Warn Gyu [Pusan National University, Busan (Korea, Republic of); Choi, Hwan Jong; Lee, Sang Hun; Oh, Sai Kee [LG Electronics, Changwon (Korea, Republic of)

    2015-11-15

    Cascade cycle is widely applied to heat pumps operating at low ambient temperature to overcome problems such as low heating capacity and Coefficient of performance (COP) deterioration A number of researches have been conducted on cascade cycle heat pumps, but most of those studies were focused on system optimization to determine optimal intermediate temperature in air-to-water heat pumps. However, experimental optimization in regard to air and water heating simultaneously using a cascade cycle has been an understudied area. Therefore, we focused on experimental analysis for a cascade system with Variable refrigerant flow (VRF) heat pumps. Experiments were conducted under a variety of operating conditions, such as ambient and water inlet temperature. COP increased up to 16% when water inlet temperature decreased. COP of VRF heat pumps with cascade cycle is three-times higher compared with conventional boilers as well as 17% higher compared to single heat pumps.

  20. Recovery Act: Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumps and Ground Source Water Loops

    Energy Technology Data Exchange (ETDEWEB)

    Jarrell, Mark

    2013-09-30

    Cedarville School District retrofitted the heating and cooling systems in three campus areas (High School, Middle School, and Upper Elementary School) with geothermal heat pumps and ground source water loops, as a demonstration project for the effective implementation of geothermal heat pump systems and other energy efficiency and air quality improvements.

  1. Multiple pump housing

    Science.gov (United States)

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  2. Systematic evaluation of a novel foot-pump ureteroscopic irrigation system.

    Science.gov (United States)

    Hendlin, Kari; Sarkissian, Carl; Duffey, Branden; Monga, Manoj

    2012-02-01

    To evaluate forces exerted on a stone with different ureteroscopic irrigation systems. A 3 mm steel simulated stone was welded to a 3F stone basket and inserted into the working channel of a 4.5F Wolf semirigid ureteroscope. The basket shaft was attached to a 50 g load cell. The urterescope was placed in a ureteral model (14F silicon tubing). Simulated blood (McCormick™ Red Dye, 1 dye drop/15 mL H(2)O) was dripped adjacent to the stone at 12 drops/min. Endoirrigation devices were attached to the ureterscope and irrigation was applied at a rate sufficient to maintain visualization of the stone. Force on the stone was measured with the following endoirrigation systems: Boston Scientific™ Single-Action-Pump System (SAP) hand-pump and NuVista Medical™ Flo-Assist(®) foot-pump. No significant difference (p=0.19) in the number of pumps required to maintain a clear endoscopic field was found between the SAP (0.20±0.075/second) and Flo-Assist device (0.25±0.056/second). The pump duration of the Flo-Assist was found to be less (1.12±0.40 seconds) than the SAP (1.35±0.31 seconds), but not significantly different (p=0.24). The average maximum impulse was significantly lower (p=0.0002) for the SAP (8.34×10(-5) Ns) than the Flo-Assist (1.96×10(-3) Ns). Total maximum impulse (2.02×10(-5) Ns) for the SAP and total average impulse (5.51×10(-6) Ns) were found to be lower than the Flo-Assist device. The Flo-Assist had a total maximum impulse of 4.49×10(-4) Ns and total average impulse of 8.85×10(-6) Ns, however, these differences were not statistically significant. The hand-pump (SAP) and foot-pump (Flo-Assist) irrigation devices tested require comparable amounts of pumps for similar durations of time to maintain endoscopic visualization. Overall, the SAP device exerts less average maximum force on the stone than the Flo-Assist device.

  3. A Study on Electric Vehicle Heat Pump Systems in Cold Climates

    Directory of Open Access Journals (Sweden)

    Ziqi Zhang

    2016-10-01

    Full Text Available Electric vehicle heat pumps are drawing more and more attention due to their energy-saving and high efficiency designs. Some problems remain, however, in the usage of the heat pumps in electric vehicles, such as a drainage problem regarding the external heat exchangers while in heat pump mode, and the decrease in heating performance when operated in a cold climate. In this article, an R134a economized vapor injection (EVI heat pump system was built and tested. The drainage problem common amongst external heat exchangers was solved by an optimized 5 mm diameter tube-and-fin heat exchanger, which can meet both the needs of a condenser and evaporator based on simulation and test results. The EVI system was also tested under several ambient temperatures. It was found that the EVI was a benefit to the system heating capacity. Under a −20 °C ambient temperature, an average improvement of 57.7% in heating capacity was achieved with EVI and the maximum capacity was 2097 W, with a coefficient of performance (COP of 1.25. The influences of injection pressure and economizer capacity are also discussed in this article.

  4. Performance enhancement of a heat pump system with ice storage subcooler

    Energy Technology Data Exchange (ETDEWEB)

    Hsiao, Ming-Jer [Department of Electrical Engineering, Nan-Kai University of Technology, No.568 Chung Cheng Road, Tsao Tun, Nan Tou, Taiwan 54243 (China); Kuo, Yu-Fu; Cheng, Chiao-Hung; Chen, Sih-Li [Department of Mechanical Engineering, National Taiwan University, No.1, Sec.4 Roosevelt Road, Taipei, Taiwan 10617 (China); Shen, Chih-Chiu [Department of Mechanical Engineering, National Chung Hsing University, No.250, Kuo Kuang Road, Taichung, Taiwan 40227 (China)

    2010-03-15

    This article experimentally investigates the thermal performance of a heat pump system with an ice storage subcooler. The system supplies heating and cooling demands to two greenhouses with temperature ranging 308{proportional_to}323 K and 273{proportional_to}291 K respectively and utilizes an ice storage tank to subcool the condensed refrigerant, which can enhance the system coefficient of performance (COP). The ice storage tank charges for storing ice, when the cooling load is less than the nominal cooling capacity. While the cooling load is larger than the nominal cooling capacity, the ice storage tank discharges for subcooling. The results show that in the charge mode the heat pump COP of ice storage system is 12% higher than that without ice storage tank. Under the discharge mode, the ice storage system provides the refrigerator COP 15% higher than that without ice storage tank. (author)

  5. Performance of hybrid quad generation system consisting of solid oxide fuel cell system and absorption heat pump

    DEFF Research Database (Denmark)

    Cachorro, Irene Albacete; Daraban, Iulia Maria; Lainé, Guillaume

    2013-01-01

    In this paper a system consisting of an SOFC system for cogeneration of heat and power and vapour absorption heat pump for cooling and freezing is assessed and performance is evaluated. Food industry where demand includes four forms of energy simultaneously is a relevant application such a system...... with natural gas. The natural gas is first converted to a mixture of H2 and CO which feed the anode after a preheating step. The cathode is supplied with preheated air and gives, as output, electrical energy. The anode output is the exhaust gas which represents the thermal energy reservoir for heating...... in order to meet the bought cooling and freezing demands. This is an innovative configuration for absorption heat pumps because the cascade is implemented only in vapour compression heat pumps. A smaller ratio of the exhausted gases supplies the energy demand for space heating. The SOFC is fuelled...

  6. Na/K pump regulation of cardiac repolarization: insights from a systems biology approach

    KAUST Repository

    Bueno-Orovio, Alfonso

    2013-05-15

    The sodium-potassium pump is widely recognized as the principal mechanism for active ion transport across the cellular membrane of cardiac tissue, being responsible for the creation and maintenance of the transarcolemmal sodium and potassium gradients, crucial for cardiac cell electrophysiology. Importantly, sodium-potassium pump activity is impaired in a number of major diseased conditions, including ischemia and heart failure. However, its subtle ways of action on cardiac electrophysiology, both directly through its electrogenic nature and indirectly via the regulation of cell homeostasis, make it hard to predict the electrophysiological consequences of reduced sodium-potassium pump activity in cardiac repolarization. In this review, we discuss how recent studies adopting the systems biology approach, through the integration of experimental and modeling methodologies, have identified the sodium-potassium pump as one of the most important ionic mechanisms in regulating key properties of cardiac repolarization and its rate dependence, from subcellular to whole organ levels. These include the role of the pump in the biphasic modulation of cellular repolarization and refractoriness, the rate control of intracellular sodium and calcium dynamics and therefore of the adaptation of repolarization to changes in heart rate, as well as its importance in regulating pro-arrhythmic substrates through modulation of dispersion of repolarization and restitution. Theoretical findings are consistent across a variety of cell types and species including human, and widely in agreement with experimental findings. The novel insights and hypotheses on the role of the pump in cardiac electrophysiology obtained through this integrative approach could eventually lead to novel therapeutic and diagnostic strategies. © 2013 Springer-Verlag Berlin Heidelberg.

  7. High power mid-IR OPCPA system pumped by a femtosecond Yb-doped fiber amplifier

    Science.gov (United States)

    Rigaud, P.; Van de Walle, A.; Hanna, M.; Forget, N.; Guichard, F.; Zaouter, Y.; Guesmi, K.; Druon, F.; Georges, P.

    2017-02-01

    We describe an optical parametric chirped pulse amplifier (OPCPA) architecture built around a state of the art Yb-doped fiber femtosecond pump source delivering 300 fs 400 μ pulses at a repetition rate 125 kHz (50 W average power) and a central wavelength of 1030 nm. The short pump pulse duration compared to bulk Yb:YAG or Nd:YVO4 based systems results in a number of important advantages. First, it allows efficient seeding at 1550 nm using supercontinuum generation directly from the pump pulses in a bulk YAG crystal, resulting in extremely robust passive pump-signal synchronization. The short pump pulse duration also allows the use of millimeter to centimeter lengths of bulk materials to provide stretching and compression for the signal and idler, which minimizes the accumulation of higher-order spectral phase. Finally, the shorter pump pulse duration increases the damage peak intensity, permitting the use of shorter nonlinear crystals to perform the amplification, which increases the spectral bandwidth of the parametric process. Additional experiments are performed to sort out the phenomena that limit power scaling in MgO:PPLN crystals. The OPCPA stages are all operated in collinear geometry, allowing the use of both signal and idler without the introduction of angular chirp on the latter. These points result in the dual generation of 70 fs 23 μJ signal pulses at 1550 nm and 60 fs 10 μJ idler pulses at 3070 nm from a simple setup, with the added benefit of inherent CEP stability of the idler pulses.

  8. Heat pump centered integrated community energy systems. System development, Franklin Research Center interim report

    Energy Technology Data Exchange (ETDEWEB)

    Crane, R E; Lorsch, H G; Werden, R G

    1979-02-01

    The concept of a heat pump centered integrated community energy system (HP-ICES) was explored based on a reference community located in the Northeast with a population of 10,000. Engineering and economic analyses were performed for the HP-ICES and for conventional heating/cooling systems. Sensitivity analyses were used to determine variations in results from changes in: community size; community energy density; waste heat utilization; energy cost escalation; maintenance and operating personnel; and central HP-ICES ownership. The effect of each of the critical parameters on the economic viability of HP-ICES is shown. Conditions of equal 20-year life cycle costs for HP-ICES and for conventional systems are given. If little or no waste heat is available from nearby industrial installations, high community energy density rates (corresponding to urban conditions) are required for economic viability of HP-ICES. If large amounts of waste heat are available, even relatively loosely built-up communities look promising provided the system is owned by the municipality. If the system is owned and operated by a shareholder-owned public utility, either the community energy density must be high, or large quantities of waste heat must be available, or electricity and oil costs must escalate rapidly during the life of the system to assure economic competitiveness with conventional systems. All HP-ICES use significantly less resource energy than conventional systems. For the baseline system analyzed, HP-ICES use 26% to 40% less resource energy than conventional systems during the heating season and 19% less energy during the peak cooling period. The annual resource energy saving for the HP-ICES is 22% to 34%. It is estimated that the HP-ICES concept is applicable to an average of 500 new communities to be constructed during the 1985--2000 period. The probable resource energy saving during that time period is 1.25 x 10/sup 15/ Btu.

  9. Hypoglycemia Prevention and User Acceptance of an Insulin Pump System with Predictive Low Glucose Management

    DEFF Research Database (Denmark)

    Choudhary, Pratik; Olsen, Birthe S; Conget, Ignacio

    2016-01-01

    BACKGROUND: The MiniMed 640G sensor-augmented insulin pump system (Medtronic, Inc., Northridge, CA) can automatically suspend insulin delivery in advance of predicted hypoglycemia and restart it upon recovery. The aims of this analysis were to determine the rate at which predicted hypoglycemia...... was avoided with this strategy, as well as to assess user acceptance of the system and its insulin management features. SUBJECTS AND METHODS: Forty subjects with type 1 diabetes used the system for 4 weeks. We retrospectively evaluated performance of the system, using downloaded pump and sensor data.......1%) of the predictive suspensions did not reach the preset low limit. Nadir SG values of ≤50 and ≤60 mg/dL were seen in 207 (8.9%) and 356 (15.3%) of the predictive suspensions, respectively. Blood glucose (BG) and SG values before and during the study were comparable (P > 0.05). The mean absolute relative difference...

  10. WASTE HEAT RECOVERY IN HEAT PUMP SYSTEMS: SOLUTION TO REDUCE GLOBAL WARMING

    Directory of Open Access Journals (Sweden)

    Y. Baradey

    2015-11-01

    Full Text Available Energy conversion technologies, where waste heat recovery systems are included, have received significant attention in recent years due to reasons that include depletion of fossil fuel, increasing oil prices, changes in climatic conditions, and global warming. For low temperature applications, there are many sources of thermal waste heat, and several recovery systems and potential useful applications have been proposed by researchers [1-4]. In addition, many types of equipment are used to recover waste thermal energy from different systems at low, medium, and high temperature applications, such as heat exchangers, waste heat recovery boiler, thermo-electric generators, and recuperators. In this paper, the focus is on waste heat recovery from air conditioners, and an efficient application of these energy resources. Integration of solar energy with heat pump technologies and major factors that affect the feasibility of heat recovery systems have been studied and reviewed as well. KEYWORDS: waste heat recovery; heat pump.

  11. Study of a centrifugal blood pump in a mock loop system.

    Science.gov (United States)

    Uebelhart, Beatriz; da Silva, Bruno Utiyama; Fonseca, Jeison; Bock, Eduardo; Leme, Juliana; da Silva, Cibele; Leão, Tarcísio; Andrade, Aron

    2013-11-01

    An implantable centrifugal blood pump (ICBP) is being developed to be used as a ventricular assist device (VAD) in patients with severe cardiovascular diseases. The ICBP system is composed of a centrifugal pump, a motor, a controller, and a power supply. The electricity source provides power to the controller and to a motor that moves the pump's rotor through magnetic coupling. The centrifugal pump is composed of four parts: external conical house, external base, impeller, and impeller base. The rotor is supported by a pivot bearing system, and its impeller base is responsible for sheltering four permanent magnets. A hybrid cardiovascular simulator (HCS) was used to evaluate the ICBP's performance. A heart failure (HF) (when the heart increases beat frequency to compensate for decrease in blood flow) was simulated in the HCS. The main objective of this work is to analyze changes in physiological parameters such as cardiac output, blood pressure, and heart rate in three situations: healthy heart, HF, and HF with left circulatory assistance by ICBP. The results showed that parameters such as aortic pressure and cardiac output affected by the HF situation returned to normal values when the ICBP was connected to the HCS. In conclusion, the test results showed satisfactory performance for the ICBP as a VAD. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  12. A Novel Constant-Pressure Pumped Hydro Combined with Compressed Air Energy Storage System

    Directory of Open Access Journals (Sweden)

    Erren Yao

    2014-12-01

    Full Text Available As intermittent renewable energy is receiving increasing attention, the combination of intermittent renewable energy with large-scale energy storage technology is considered as an important technological approach for the wider application of wind power and solar energy. Pumped hydro combined with compressed air energy storage system (PHCA is one of the energy storage systems that not only integrates the advantages but also overcomes the disadvantages of compressed air energy storage (CAES systems and pumped hydro energy storage systems to solve the problem of energy storage in China’s arid regions. Aiming at the variable working conditions of PHCA system technology, this study proposes a new constant-pressure PHCA. The most significant characteristics of this system were that the water pump and hydroturbine work under stable conditions and this improves the working efficiency of the equipment without incurring an energy loss. In addition, the constant-pressure PHCA system was subjected to energy and exergy analysis, in expectation of exploring an attractive solution for the large-scale storage of existing intermittent renewable energy.

  13. Performance Analysis of a Hot Water Supply System with a CO2 Heat Pump by Numerical Simulation

    Science.gov (United States)

    Yokoyama, Ryohei; Shimizu, Takeshi; Takemura, Kazuhisa; Ito, Koichi

    Heat pumps using CO2 as a natural refrigerant have been developed and are expected to contribute to energy saving in hot water supply. In residential applications, CO2 heat pumps are used in combination with hot water storage tanks. The objective of this series of papers is to analyze the overall performance of a hot water supply system composed of a CO2 heat pump and a hot water storage tank by numerical simulation. In the 1st report, a simulation model of a CO2 heat pump is created based on thermodynamic equations and measured data for an existing CO2 heat pump. In addition, the performance of a CO2 heat pump is clarified in relation to the air temperature as well as the inlet and outlet water temperatures.

  14. On the solution of the outgassing equation for the pump-down of an unbaked vacuum system

    Energy Technology Data Exchange (ETDEWEB)

    Akaishi, K. [National Inst. for Fusion Science, Toki, Gifu (Japan)

    1997-10-01

    The outgassing equation based on the Temkin isotherm is presented to consider the outgassing behaviour in the pump-down of an unbaked vacuum system. A method to solve approximately the equation is discussed first and then solutions of outgassing rates are derived. Discussion is made how to derive appropriate solutions from the equation which are possible to predict the dependence of outgassing rate on pumping time and pumping speed. Solutions obtained finally are possible to explain consistently the outgassing behaviour observed experimentally for 304 stainless steel chamber after exposure to moist air concerning the dependence of outgassing rate on time and pumping speed. (author)

  15. Stochastic pump effect and geometric phases in dissipative and stochastic systems

    Energy Technology Data Exchange (ETDEWEB)

    Sinitsyn, Nikolai [Los Alamos National Laboratory

    2008-01-01

    The success of Berry phases in quantum mechanics stimulated the study of similar phenomena in other areas of physics, including the theory of living cell locomotion and motion of patterns in nonlinear media. More recently, geometric phases have been applied to systems operating in a strongly stochastic environment, such as molecular motors. We discuss such geometric effects in purely classical dissipative stochastic systems and their role in the theory of the stochastic pump effect (SPE).

  16. Technical Report for Water Circulation Pumping System for Trihalomethanes (THMs)

    Energy Technology Data Exchange (ETDEWEB)

    Bellah, W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-06-08

    The TSWWS was added as an active source of supply to the permit (No. 03-10-13P-003) in 2010, but has never been used due to the potential for formation of trihalomethanes (THMs) in the distribution system. THMs are formed as a by-product when chlorine is used to disinfect water for drinking. THMs are a group of chemicals generally referred to as disinfection by-products (DBPs). THMs result from the reaction of chlorine with organic matter that is present in the water. Some of the THMs are volatile and may easily vaporize into the air. This fact forms the basis of the design of the system discussed in this technical report. In addition, the design is based on the results of a study that has shown success using aeration as a means to reduce TTHMs to within allowable concentration levels with turn-over times as long as ten days. The Primary Drinking Water Standards of Regulated Contaminants Maximum Contaminant Level (MCL) for TTHMs is 80 parts per billion (ppb). No other changes to the existing drinking water distribution system and chlorination operations are anticipated before switching to the TSWWS as the primary drinking water source. The two groundwater wells (Wells 20 and 18) which are currently the primary and backup water sources for the system would be maintained for use as backup supply. In the future, one of the wells may be removed from the system. A permit amendment would be filed at that time if this modification was deemed appropriate.

  17. Preliminary Feasibility Study of a Hybrid Solar and Modular Pumped Storage Hydro System at Biosphere 2

    Energy Technology Data Exchange (ETDEWEB)

    Lansey, Kevin [Univ. of Arizona, Tucson, AZ (United States); Hortsman, Chris [Univ. of Arizona, Tucson, AZ (United States)

    2016-10-01

    In this study, the preliminary feasibility of a hybrid solar and modular pumped storage system designed for high energy independence at Biosphere 2 is assessed. The system consists of an array of solar PV panels that generate electricity during the day to power both Biosphere 2 and a pump that sends water through a pipe to a tank at a high elevation. When solar power is not available, the water is released back down the pipe towards a tank at a lower elevation, where it passes through a hydraulic water turbine to generate hydroelectricity to power Biosphere 2. The hybrid system is sized to generate and store enough energy to enable Biosphere 2 to operate without a grid interconnection on an average day.

  18. Study on a groundwater source heat pump cooling system in solar greenhouse

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Lilong; Ma, Chengwei [China Agricultural Univ., Beijing (China). Coll. of Water Conservancy and Civil Engineering. Dept. of Agricultural Structure and Bio-environmental Engineering], E-mail: macwbs@cau.edu.cn

    2008-07-01

    This study aims at exploiting the potential of ground source heat pump (GSHP) technology in cooling agricultural greenhouse, and advocating the use of renewable and clean energy in agriculture. GSHP has the multi-function of heating, cooling and dehumidifying, which is one of the fastest growing technologies of renewable energy air conditioning in recent years. The authors carried out experiment on the ground source heat pump system in cooling greenhouse in Beijing region during the summertime of 2007, and conducted analysis on the energy efficiency of the system by using coefficient of performance (COP). According to the data collected during Aug.13-18th, 2007, the coefficient of performance of GSHP system (COP{sub sys}) has reached 3.15 on average during the test. (author)

  19. Efficiency optimization of a photovoltaic water pumping system for irrigation in Ouargla, Algeria

    Science.gov (United States)

    Louazene, M. L.; Garcia, M. C. Alonso; Korichi, D.

    2017-02-01

    This work is technical study to contribute to the optimization of pumping systems powered by solar energy (clean) and used in the field of agriculture. To achieve our goals, we studied the techniques that must be entered on a photovoltaic system for maximum energy from solar panels. Our scientific contribution in this research is the realization of an efficient photovoltaic pumping system for irrigation needs. To achieve this and extract maximum power from the PV generator, two axes have been optimized: 1. Increase in the uptake of solar radiation by choice an optimum tilt angle of the solar panels, and 2. it is necessary to add an adaptation device, MPPT controller with a DC-DC converter, between the source and the load.

  20. OPAL - extension for use with ventilation and pump systems; OPAL-Erweiterung mit Luefter- und Pumpensystemen

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, R.

    2003-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) discusses how an existing software tool called OPAL that supports the energy-efficient dimensioning of electrical drive systems was extended to cover pump and fan applications. According to the authors, the new version 3 allows the energy efficiency of such systems as well as the economic feasibility of many types of improvement projects to be evaluated in a fast and accurate manner. Software is described that has been designed and optimised using real world examples that can be often found in the water supply and facility management areas. These include heating-system pumps as well as ventilation and pressure-boosting applications. The practicability and benefits offered by the tool are demonstrated using several examples.

  1. Wind power integration with heat pumps, heat storages, and electric vehicles – Energy systems analysis and modelling

    DEFF Research Database (Denmark)

    Hedegaard, Karsten

    in an energy system context. Energy systems analyses reveal that the heat pumps can even without flexible operation contribute significantly to facilitating larger wind power investments and reducing system costs, fuel consumption, and CO2 emissions. When equipping the heat pumps with heat storages, only......The fluctuating and only partly predictable nature of wind challenges an effective integration of large wind power penetrations. This PhD thesis investigates to which extent heat pumps, heat storages, and electric vehicles can support the integration of wind power. Considering the gaps in existing...... research, main focus is put on individual heat pumps in the residential sector and the possibilities for flexible operation, using the heat storage options available. Extensive model development is performed that significantly improves the possibilities for analysing individual heat pumps and heat storages...

  2. Theoretical study on volatile organic compound removal and energy performance of a novel heat pump assisted solid desiccant cooling system

    DEFF Research Database (Denmark)

    Nie, Jinzhe; Fang, Lei; Zhang, Ge

    2015-01-01

    A theoretical model was established for predicting the volatile organic compound (VOC) removal and energy performance of a novel heat pump assisted solid desiccant cooling system (HP-SDC). The HP-SDC was proposed based on the combination of desiccant rotor with heat pump, and was designed...

  3. A Fourier Approximation Method for the Multi-Pump Multi-Piston Power Take-Off System

    NARCIS (Netherlands)

    Wei, Yanji; Barradas Berglind, Jose de Jesus; Muhammad Zaki Almuzakki, M.; van Rooij, Marijn; Wang, Ruoqi; Jayawardhana, Bayu; Vakis, Antonis I.

    2018-01-01

    In this work, a frequency-domain method for the numerical solution of the nonlinear dynamics of a wave energy converter with a pumping system is presented. To this end, a finite Fourier series is used to describe the nonlinear force components, i.e., the pumping force. The dynamics of the buoy and

  4. Research on the performance of low-lift diving tubular pumping system by CFD and Test

    Science.gov (United States)

    Xia, Chenzhi; Cheng, Li; Liu, Chao; Zhou, Jiren; Tang, Fangping; Jin, Yan

    2016-11-01

    Post-diving tubular pump is always used in large-discharge & low-head irrigation or storm drainage pumping station, its impeller and motor share the same shaft. Considering diving tubular pump system's excellent hydraulic performance, compact structure, good noise resistance and low operating cost, it is used in Chinese pump stations. To study the hydraulic performance and pressure fluctuation of inlet and outlet passage in diving tubular pump system, both of steady and unsteady full flow fields are numerically simulated at three flow rate conditions by using CFD commercial software. The asymmetry of the longitudinal structure of inlet passage affects the flow pattern on outlet. Especially at small flow rate condition, structural asymmetry will result in the uneven velocity distribution on the outlet of passage inlet. The axial velocity distribution uniformity increases as the flow rate increases on the inlet of passage inlet, and there is a positive correlation between hydraulic loss in the passage inlet and flow rate's quadratic. The axial velocity distribution uniformity on the outlet of passage inlet is 90% at design flow rate condition. The predicted result shows the same trend with test result, and the range of high efficiency area between predicted result and test result is almost identical. The dominant frequency of pressure pulsation is low frequency in inlet passage at design condition. The dominant frequency is high frequency in inlet passage at small and large flow rate condition. At large flow rate condition, the flow pattern is significantly affected by the rotation of impeller in inlet passage. At off-design condition, the pressure pulsation is strong at outlet passage. At design condition, the dominant frequency is 35.57Hz, which is double rotation frequency.

  5. Wind power integration with heat pumps, heat storages, and electric vehicles - Energy systems analysis and modelling

    Energy Technology Data Exchange (ETDEWEB)

    Hedegaard, K.

    2013-09-15

    This PhD investigates to which extent heat pumps, heat storages, and electric vehicles can support the integration of wind power. Considering the gaps in existing research, the main focus is put on individual heat pumps in the residential sector (one-family houses) and the possibilities for flexible operation, using the heat storage options available. Several energy systems analyses are performed using the energy system models, Balmorel, developed at the former TSO, ElkraftSystem, and, EnergyPLAN, developed at Aalborg University. The Danish energy system towards 2030, with wind power penetrations of up to 60 %, is used as a case study in most of the analyses. Both models have been developed further, resulting in an improved representation of individual heat pumps and heat storages. An extensive model add-on for Balmorel renders it possible to optimise investment and operation of individual heat pumps and different types of heat storages, in integration with the energy system. Total costs of the energy system are minimised in the optimisation. The add-on incorporates thermal building dynamics and covers various different heat storage options: intelligent heat storage in the building structure for houses with radiator heating and floor heating, respectively, heat accumulation tanks on the space heating circuit, as well as hot water tanks. In EnergyPLAN, some of the heat storage options have been modelled in a technical optimisation that minimises fuel consumption of the energy system and utilises as much wind power as possible. The energy systems analyses reveal that in terms of supporting wind power integration, the installation of individual heat pumps is an important step, while adding heat storages to the heat pumps is less influential. When equipping the heat pumps with heat storages, only moderate system benefits can be gained. Hereof, the main system benefit is that the need for peak/reserve capacity investments can be reduced through peak load shaving; in

  6. Intelligent Diagnosis Method for Centrifugal Pump System Using Vibration Signal and Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Hongtao Xue

    2014-01-01

    Full Text Available This paper proposed an intelligent diagnosis method for a centrifugal pump system using statistic filter, support vector machine (SVM, possibility theory, and Dempster-Shafer theory (DST on the basis of the vibration signals, to diagnose frequent faults in the centrifugal pump at an early stage, such as cavitation, impeller unbalance, and shaft misalignment. Firstly, statistic filter is used to extract the feature signals of pump faults from the measured vibration signals across an optimum frequency region, and nondimensional symptom parameters (NSPs are defined to represent the feature signals for distinguishing fault types. Secondly, the optimal classification hyperplane for distinguishing two states is obtained by SVM and NSPs, and its function is defined as synthetic symptom parameter (SSP in order to increase the diagnosis’ sensitivity. Finally, the possibility functions of the SSP are used to construct a sequential fuzzy diagnosis for fault detection and fault-type identification by possibility theory and DST. The proposed method has been applied to detect the faults of the centrifugal pump, and the efficiency of the method has been verified using practical examples.

  7. Study on the Effect of Reciprocating Pump Pipeline System Vibration on Oil Transportation Stations

    Directory of Open Access Journals (Sweden)

    Hongfang Lu

    2018-01-01

    Full Text Available Due to the periodic movement of the piston in the reciprocating pump, the fluid will cause a pressure pulsation, and the resulting pipeline vibration may lead to instrument distortion, pipe failure and equipment damage. Therefore, it is necessary to study the vibration phenomena of reciprocating pump pipelines based on pressure pulsation theory. This paper starts from the reciprocating pump pipe pressure pulsation caused by a fluid, pressure pulsation in the pipeline and the unbalanced exciting force is calculated under the action of the reciprocating pump. Then, the numerical simulation model is established based on the pipe beam model, and the rationality of the numerical simulation method is verified by indoor experiments. Finally, a case study is taken as an example to analyze the vibration law of the pipeline system, and vibration reduction measures are proposed. The following main conclusions are drawn from the analysis: (1 unbalanced exciting forces are produced in the elbows or tee joints, and it can also influence the straight pipe to different levels; (2 in actual engineering, it should be possible to prevent the simultaneous settlement of multiple places; (3 the vibration amplitude increases with the pipe thermal stress, and when the oil temperature is higher than 85 °C, it had a greater influence on the vertical vibration amplitude of the pipe.

  8. Performance analysis of photovoltaic-powered water-pumping systems using switched reluctance motor drives

    Science.gov (United States)

    Metwally, Hamid M. B.; Anis, Wagdy R.

    A photovoltaic-powered (PV) pumping system that uses a switched reluctance motor (SRM) is investigated. The motor is supplied by a d.c. voltage through a switching circuit. The drive circuit is much simpler than the normal d.c./a.c. inverter that is required to supply the induction motor. The efficiency of the SRM is considerably higher than that of equivalent d.c. or induction motors. In addition, because of the simple construction, the SRM is cheaper. By virtue of these advantages of the SRM, the proposed system has higher efficiency and lower cost compared with other systems. A design example is studied in detail to explore the advantages of PV pumping systems based on this new drive. It is found that the operating efficiency of the motor is about 85% during most of its working time. The matching efficiency between the PV array and the proposed system approaches 95%. The major part of the losses takes place in the pump and the riser pipes; this loss represents one-third of the total available energy.

  9. Heat-Pump-Centered Integrated Community Energy Systems: system development. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dubin, F S; Halfon, A; Herzog, P

    1979-08-01

    The ice-generating HP-ICES uses the heat of fusion of water as a heat source for the heat pump, thus converting the water into ice. The ice will be stored in a bin and used the following summer for cooling which, therefore, could be considered a by-product of heating. The annual overall Coefficient of Performance is expected to reach a value of 4.85 and related to source energy a value of 4.85 x 0.31 = 1.5. In a detailed case study on the Market Square project in Washington, D.C., it was found that for the HP-ICES the annual source energy input is about 60% and the life cycle annual average cost is 40% of the corresponding quantities for a conventional central system with equal heating and cooling capacity. The annual average operating and administration cost for the HP-ICES is less than 70% of the corresponding costs for the conventional system, while the first cost of the HP-ICES is about 70% larger than the first cost of the conventional system. With the values assumed for the discount rate, interest rate, etc., the return on investment was found to be about 15%, which gives a discounted payback period of about 6.7 years. For the Park Plaza in Boston, the annual source energy input for the HP-ICES is 35% and the energy cost is about 30% of the corresponding quantities for the conventional system. The annual average operating and administration cost for the HP-ICES is 4.5 times as great as the first cost for the conventional system. The return on investment is 13% and the payback is 8 years. These results show that the HP-ICES can be better both in energy usage and in life cycle cost than a conventional system of the same heating and cooling capacity, and holds great promise as an energy saving system.

  10. Heat pump for district cooling and heating at Oslo Airport, Gardermoen[Aquifer thermal energy systems (ATES)

    Energy Technology Data Exchange (ETDEWEB)

    Eggen, Geir; Vangsnes, Geir

    2006-07-01

    At Gardermoen, one of the largest groundwater reservoirs in Norway is located. This aquifer is used for both heating and cooling of Gardermoen Airport. In the summer, ground water is pumped from cold wells and used for cooling before it is returned to the warm wells. In winter, this process is turned around, as ground water from the warm wells is used as heat source for the heat pump. The heat pump is mainly designed for cooling, and the design cooling demand is 9 MW. The district cooling water is pre-cooled by the ground water, and post cooled by the combined heat pump/refrigeration plant. The base heat load is covered by the heat pump. Additional heat is supplied from a heat energy central with bio fuels as well as oil heated and electrically heated boilers. During the last years, heat production from the heat pump was about 11 GWh/year, and the heat pump also provides about 8 GWh/year of the cooling demand. In addition, approximately 3 GWh/year cold is produced by direct heat exchange with ground water. Compared with a district heating system heated by fossil fuels, and a conventional refrigeration system for district cooling, the pay back period for the aquifer heat pump system is within a couple of years (author) (ml)

  11. Binary blend of carbon dioxide and fluoro ethane as working fluid in transcritical heat pump systems

    Directory of Open Access Journals (Sweden)

    Zhang Xian-Ping

    2015-01-01

    Full Text Available As an eco-friendly working fluid, carbon dioxide or R744 is expected to substitute for the existing working fluids used in heat pump systems. It is, however, challenged by the much higher heat rejection pressure in transcritical cycle compared with the traditional subcritical cycle using freons. There exists a worldwide tendency to utilize blend refrigerants as alternatives. Therefore, a new binary blend R744/R161 in this research is proposed in order to decrease the heat rejection pressure. Meanwhile, on mixing R744 with R161, the flammability and explosivity of R161 can be suppressed because of the extinguishing effect of R744. A transcritical thermodynamic model is developed, and then the system performances of heat pump using R744/R161 blend are investigated and compared with those of pure R744 system under the same operation conditions. The variations of heat rejection pressure, heating coefficient of performance, unit volumetric heating capacity, discharge temperature of compressor and the mass fraction of R744/R161 are researched. The results show that R744/R161 mixture can reduce the heat rejection pressure of transcritical heat pump system.

  12. Closed-loop helium circulation system for actuation of a continuously operating heart catheter pump.

    Science.gov (United States)

    Karabegovic, Alen; Hinteregger, Markus; Janeczek, Christoph; Mohl, Werner; Gföhler, Margit

    2017-06-09

    Currently available, pneumatic-based medical devices are operated using closed-loop pulsatile or open continuous systems. Medical devices utilizing gases with a low atomic number in a continuous closed loop stream have not been documented to date. This work presents the construction of a portable helium circulation addressing the need for actuating a novel, pneumatically operated catheter pump. The design of its control system puts emphasis on the performance, safety and low running cost of the catheter pump. Static and dynamic characteristics of individual elements in the circulation are analyzed to ensure a proper operation of the system. The pneumatic circulation maximizes the working range of the drive unit inside the catheter pump while reducing the total size and noise production.Separate flow and pressure controllers position the turbine's working point into the stable region of the pressure creation element. A subsystem for rapid gas evacuation significantly decreases the duration of helium removal after a leak, reaching subatmospheric pressure in the intracorporeal catheter within several milliseconds. The system presented in the study offers an easy control of helium mass flow while ensuring stable behavior of its internal components.

  13. Improvement Analysis in a Municipal Pumping System Aiming the Energy Efficiency

    Directory of Open Access Journals (Sweden)

    Rafael Fernando Dutra

    2014-08-01

    Full Text Available With the rapid and disorderly growth that occurred in the city of Caxias do Sul - RS in the last two decades, many problems of water supply are observed in specific areas, especially in peak times and days of consumption. In order to solve the mentioned problem and focusing on energy efficiency, this study proposed two improvements in the pumping system of Santa Fe, which is responsible for supplying the northern part of Caxias do Sul. The improvements mentioned dealt with the exchange of the pumping system and the use of a frequency converter to control its speed. From the measurements made and simulations in spreadsheets and software Epanet, it was found that the two improvements are technically and economically viable, providing an estimated monthly savings of 37.7%.

  14. Speed-variable Switched Differential Pump System for Direct Operation of Hydraulic Cylinders

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Roemer, Daniel Beck; Pedersen, Henrik Clemmensen

    2015-01-01

    Efforts to overcome the inherent loss of energy due to throttling in valve driven hydraulic systems are many, and various approaches have been proposed by research communities as well as the industry. Recently, a so-called speed-variable differential pump was proposed for direct drive of hydraulic...... may seriously influence the dynamics and hence the performance during operation. This paper presents an analysis of these properties, and a redesign of the hydraulic system concept is proposed. Here the area- and displacement ratios are deliberately mismatched, causing inherent pressure build...... features are verified by comparison with the original pump concept and a conventional valve concept. Furthermore, significant improvement in energy efficiency is demonstrated under certain load conditions....

  15. Experimental Performance of a Thermoelectric Heat-Pump Drying System for Drying Herbs

    Science.gov (United States)

    Wongsim, K.; Jamradloedluk, J.; Lertsatitthanakorn, C.; Siriamornpun, S.; Rungsiyopas, M.; Soponronnarit, S.

    2015-06-01

    In this study we investigated thermoelectric (TE) heat-pump drying of laurel clock vine leaves, and the effect of drying-air temperature on the characteristics of the leaves. The TE drying system comprised four TE modules each with its own rectangular fin heat sink. The hot side of each TE module was fixed to its own heat sink; the cold sides were fixed to heat-pipe heat sinks and a drying chamber. The drying time depended on drying-air temperature. The heating capacity and coefficient of performance (COP) increased as the current supplied to the TE modules was increased. Calculated COP for the entire TE heat-pump drying system were 1.28 and 0.81 for drying-air temperatures of 50 and 40°C, respectively.

  16. Study and Development of an Air Conditioning System Operating on a Magnetic Heat Pump Cycle

    Science.gov (United States)

    Wang, Pao-Lien

    1991-01-01

    This report describes the design of a laboratory scale demonstration prototype of an air conditioning system operating on a magnetic heat pump cycle. Design parameters were selected through studies performed by a Kennedy Space Center (KSC) System Simulation Computer Model. The heat pump consists of a rotor turning through four magnetic fields that are created by permanent magnets. Gadolinium was selected as the working material for this demonstration prototype. The rotor was designed to be constructed of flat parallel disks of gadolinium with very little space in between. The rotor rotates in an aluminum housing. The laboratory scale demonstration prototype is designed to provide a theoretical Carnot Cycle efficiency of 62 percent and a Coefficient of Performance of 16.55.

  17. Heat pump air conditioning system for pure electric vehicle at ultra-low temperature

    Directory of Open Access Journals (Sweden)

    Li Hai-Jun

    2014-01-01

    Full Text Available When the ordinary heat pump air conditioning system of a pure electric vehicle runs at ultra-low temperature, the discharge temperature of compressor will be too high and the heating capacity of the system will decay seriously, it will lead to inactivity of the heating system. In order to solve this problem, a modification is put forward, and an experiment is also designed. The experimental results show that in the same conditions, this new heating system increases more than 20% of the heating capacity; when the outside environment temperature is negative 20 degrees, the discharge temperature of compressor is below 60 degrees.

  18. Structure of microprocessor-based automation system of oil pumping station “Alexndrovskaya”

    Directory of Open Access Journals (Sweden)

    Dmitriyenko Margarita A.

    2014-01-01

    Full Text Available Structure of microprocessed-based automation system (MBAS of oil pumping station (OPS «Alexandrovskaya», located on the territory of Tomsk region and forming part of the Oil Transporting Joint Stock Company «Transneft», developed in accordance with the requirements of the guidance document «Complex of the typical design choices automation of OPSs and crude storages on the basis of modern standard solutions and components».

  19. Research on the System of Pulse Synthesis Pre-pump Rayleigh BOTDA technology

    OpenAIRE

    Shang Qiufeng; Ren Wengang; Mao Xun; Zhang Lixin

    2015-01-01

    The conventional Rayleigh scattering Brillouin Optical Time Domain Analysis (Rayleigh BOTDA) system adopted the leakage light ahead of the pump pulse to generate Rayleigh back-scattering light. Stimulated Brillouin scattering (SBS) interacts between an optical pulse and a Rayleigh back-scattering light, then the temperature and strain information of the optical fiber are perceived by measuring the Rayleigh scattering light. However, the width of pulse is inversely proportional to the accuracy...

  20. Design Considerations of PV Water Pumping and Rural Electricity System (2011) in Lower Myanmar

    OpenAIRE

    Nang Saw Yuzana Kya ing; Wunna Swe

    2011-01-01

    Photovoltaic (PV) systems provides a viable means of power generation for applications like powering residential appliances, electrification of villages in rural areas, refrigeration and water pumping. Photovoltaic-power generation is reliable. The operation and maintenance costs are very low. Since Myanmar is a land of plentiful sunshine, especially in central and southern regions of the country, the solar energy could hopefully become the final solution to its energy su...

  1. Parametric Optimization of Control Systems Pumping Station by the Genetic Algorithms

    Directory of Open Access Journals (Sweden)

    M. P. Dounaev

    2014-01-01

    Full Text Available Now the frequency regulation with its well-known advantages is becoming more popular for using in electric drives. One of these systems is the system of liquid flow stabilization for pumping station of the second flood, which is discussed at the article. There are functional elements of the system: the frequency converter, the induction motor, pump set, check valve, part of the pipeline between the flow sensors and PID controller. In this case are used PID controller with universal input and RS-485 OWEN TRM101.The article tries to solve the main problem, which is to set optimal controller settings. The article presents a mathematical model of the system, built on the basis of transfer functions. The specific values of the parameters for Bratsk pumping station of the second flood are found.To solve the problem of parametric optimization for control of pumping station authors use a genetic algorithm, which allows us to use different quality criteria. A set of parameters for the genetic algorithm is represented, as well as a method of selection and a method of the transition between generations. The problem of parametric optimization was solved by quadratic integral criterion and by the criterion, composed of direct measures of quality (regulation time and the overshoot. The PID controller optimal values of adjustable parameters were obtained both for considered criteria and for their corresponding transient processes. Comparative analysis of results was produced. When proving the optimality of the obtained settings for the quadratic criterion the proximity of the gradient components of the target functional to zero is demonstrated. In the case of a criterion based on a direct measure of quality, is presented a picture of convergence of adjustable parameters to the same value when run with different starting points.It is presented that the use of a criterion based on a direct measure of quality, can significantly reduce the overshoot with a

  2. Use of sediment CO2 by submersed rooted plants

    DEFF Research Database (Denmark)

    Winkel, Anders; Borum, Jens

    2009-01-01

    freshwater plants with different morphology and growth characteristics (Lobelia dortmanna, Lilaeopsis macloviana, Ludwigia repens, Vallisneria americana and Hydrocotyle verticillata) are able to support photosynthesis supplied by uptake of CO2 from the sediment. Methods: Gross photosynthesis was measured......Background and Aims: Submersed plants have different strategies to overcome inorganic carbon limitation. It is generally assumed that only small rosette species (isoetids) are able to utilize the high sediment CO2 availability. The present study examined to what extent five species of submersed......, the shoot to root ratio on an areal basis was the single factor best explaining variability in the importance of sediment CO2. For Ludwigia, diffusion barriers limited uptake or transport from roots to stems and transport from stems to leaves. Conclusions: Submersed plants other than isoetids can utilize...

  3. Intelligent real-time operation of a pumping station for an urban drainage system

    Science.gov (United States)

    Hsu, Nien-Sheng; Huang, Chien-Lin; Wei, Chih-Chiang

    2013-05-01

    SummaryIn this study, we apply artificial intelligence techniques to the development of two real-time pumping station operation models, namely, a historical and an optimized adaptive network-based fuzzy inference system (ANFIS-His and ANFIS-Opt, respectively). The functions of these two models are the determination of the real-time operation criteria of various pumping machines for controlling flood in an urban drainage system during periods when the drainage gate is closed. The ANFIS-His is constructed from an adaptive network-based fuzzy inference system (ANFIS) using historical operation records. The ANFIS-Opt is constructed from an ANFIS using the best operation series, which are optimized by a tabu search of historical flood events. We use the Chung-Kong drainage basin, New Taipei City, Taiwan, as the study area. The operational comparison variables are the highest water level (WL) and the absolute difference between the final WL and target WL of a pumping front-pool. The results show that the ANFIS-Opt is better than the ANFIS-His and historical operation models, based on the operation simulations of two flood events using the two operation models.

  4. Performance evaluation of heat pump system using R744/R161 mixture refrigerant

    Directory of Open Access Journals (Sweden)

    Zhang Xian-Ping

    2014-01-01

    Full Text Available As an efficient and energy conservation technology, heat pumps working with R22, which are scheduled to be phased out by Montreal Protocol, are widely used in China at present. The global deteriorating ecology environment would accelerate the phase-out time of R22 in developing countries. Therefore, as a matter of urgency, an eco-friendly substitute should be investigated in order to replace R22. Under this context, and with a consideration of the environmental protection, R744/R161 mixture refrigerant is proposed. R744/R161 mixture refrigerant’s condensation pressure is reduced and its flammability and explosivity are suppressed. A thermodynamic model is developed, and under the given working conditions, the performances of subcritical heat pump system using R744/R161 mixture of variable mass fraction are discussed and compared with those of the R22 system. The optimal mass fraction of R744/R161 is given, which corresponds to a maximal heating coefficient of performance. The simulation results show that R744/R161 mixture can work as a competitive alternative to R22 in heat pump system.

  5. Comparison of solar heat pump systems to conventional methods for residential heating, cooling, and water heating, volume 2

    Science.gov (United States)

    Hughes, P. J.; Morehouse, J. H.

    1980-04-01

    The series and parallel combined solar heat pump systems investigated are at best marginally competitive, on a 20 year life cycle cost basis, with conventional oil and electric furnace systems. The combined solar heat pump systems are not economically competitive with conventional gas furnace or stand alone heat pump systems for residential space heating, cooling and water heating. The combined solar heat pump systems do offer the potential for significant energy savings as compared to conventional furnace systems and the stand alone heat pump. The cost of that savings, however, is beyond that which the average consumer can be expected to pay. Barring unforeseen manufacturing process or materials breakthroughs, parallel systems prices are firm. The prices listed for series systems already include low cost site built collectors and an optimistic estimate of the liquid to air heat pump costs, and prices on other series system components are firm. A collector cost sensitivity analysis did not offer any encouraging directions towards significant systems cost reduction.

  6. Development of a Novel Antimicrobial Screening System Targeting the Pyoverdine-Mediated Iron Acquisition System and Xenobiotic Efflux Pumps

    Directory of Open Access Journals (Sweden)

    Kazuki Sato

    2015-04-01

    Full Text Available The iron acquisition systems in Pseudomonas aeruginosa are inducible in response to low-iron conditions and important for growth of this organism under iron limitation. OprM is the essential outer membrane subunit of the MexAB-OprM xenobiotic efflux pump. We designed and constructed a new model antimicrobial screening system targeting both the iron-uptake system and xenobiotic efflux pumps. The oprM gene was placed immediately downstream of the ferri-pyoverdine receptor gene, fpvA, in the host lacking chromosomal oprM and the expression of oprM was monitored by an antibiotic susceptibility test under iron depleted and replete conditions. The recombinant cells showed wild-type susceptibility to pump substrate antibiotics, e.g., aztreonam, under iron limitation and became supersusceptible to them under iron repletion, suggesting that expression of oprM is under control of the iron acquisition system. Upon screening of a chemical library comprising 2952 compounds using this strain, a compound—ethyl 2-(1-acetylpiperidine-4-carboxamido-4,5,6,7-tetrahydrobenzo[b]thiophene-3-carboxylate—was found to enhance the efficacy of aztreonam under iron limitation, suggesting that the compound inhibits either the iron acquisition system or the MexAB-OprM efflux pump. This compound was subsequently found to inhibit the growth of wild-type cells in the presence of sublethal amounts of aztreonam, regardless of the presence or absence of dipyridyl, an iron-chelator. The compound was eventually identified to block the function of the MexAB-OprM efflux pump, showing the validity of this new method.

  7. Modelling of the work processes high-pressure pump of common rail diesel injection system

    Directory of Open Access Journals (Sweden)

    Botwinska Katarzyna

    2016-01-01

    Full Text Available Common rail injection systems are becoming a more widely used solution in the fuel systems of modern diesel engines. The main component and the characteristic feature of the system is rail injection of the fuel under high pressure, which is passed to the injector and further to the combustion chamber. An important element in this process is the high-pressure pump, continuing adequate pressure in the rail injection system. Common rail (CR systems are being modified in order to optimise their work and virtual simulations are a useful tool in order to analyze the correctness of operation of the system while varying the parameters and settings, without any negative impact on the real object. In one particular study, a computer simulation of the pump high-pressure CR system was made in MatLab environment, based on the actual dimensions of the object – a one-cylinder diesel engine, the Farymann Diesel 18W. The resulting model consists of two parts – the first is responsible for simulating the operation of the high-pressure pump, and the second responsible for simulation of the remaining elements of the CR system. The results of this simulation produced waveforms of the following parameters: fluid flow from the manifold to the injector [m3/s], liquid flow from the manifold to the atmosphere [m3/s], and manifold pressure [Pa]. The simulation results allow for a positive verification of the model and the resulting system could become a useful element of simulation of the entire position and control algorithm.

  8. Pump RIN-induced impairments in unrepeatered transmission systems using distributed Raman amplifier.

    Science.gov (United States)

    Cheng, Jingchi; Tang, Ming; Lau, Alan Pak Tao; Lu, Chao; Wang, Liang; Dong, Zhenhua; Bilal, Syed Muhammad; Fu, Songnian; Shum, Perry Ping; Liu, Deming

    2015-05-04

    High spectral efficiency modulation format based unrepeatered transmission systems using distributed Raman amplifier (DRA) have attracted much attention recently. To enhance the reach and optimize system performance, careful design of DRA is required based on the analysis of various types of impairments and their balance. In this paper, we study various pump RIN induced distortions on high spectral efficiency modulation formats. The vector theory of both 1st and higher-order stimulated Raman scattering (SRS) effect using Jones-matrix formalism is presented. The pump RIN will induce three types of distortion on high spectral efficiency signals: intensity noise stemming from SRS, phase noise stemming from cross phase modulation (XPM), and polarization crosstalk stemming from cross polarization modulation (XPolM). An analytical model for the statistical property of relative phase noise (RPN) in higher order DRA without dealing with complex vector theory is derived. The impact of pump RIN induced impairments are analyzed in polarization-multiplexed (PM)-QPSK and PM-16QAM-based unrepeatered systems simulations using 1st, 2nd and 3rd-order forward pumped Raman amplifier. It is shown that at realistic RIN levels, negligible impairments will be induced to PM-QPSK signals in 1st and 2nd order DRA, while non-negligible impairments will occur in 3rd order case. PM-16QAM signals suffer more penalties compared to PM-QPSK with the same on-off gain where both 2nd and 3rd order DRA will cause non-negligible performance degradations. We also investigate the performance of digital signal processing (DSP) algorithms to mitigate such impairments.

  9. Recovery Act: Finite Volume Based Computer Program for Ground Source Heat Pump Systems

    Energy Technology Data Exchange (ETDEWEB)

    James A Menart, Professor

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled Finite Volume Based Computer Program for Ground Source Heat Pump Systems. The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The

  10. Finite Volume Based Computer Program for Ground Source Heat Pump System

    Energy Technology Data Exchange (ETDEWEB)

    Menart, James A. [Wright State University

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ?Finite Volume Based Computer Program for Ground Source Heat Pump Systems.? The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump

  11. Organizational, Cultural, and Psychological Determinants of Smart Infusion Pump Work Arounds: A Study of 3 U.S. Health Systems.

    Science.gov (United States)

    Dunford, Benjamin B; Perrigino, Matthew; Tucker, Sharon J; Gaston, Cynthia L; Young, Jim; Vermace, Beverly J; Walroth, Todd A; Buening, Natalie R; Skillman, Katherine L; Berndt, Dawn

    2017-09-01

    We investigated nurse perceptions of smart infusion medication pumps to provide evidence-based insights on how to help reduce work around and improve compliance with patient safety policies. Specifically, we investigated the following 3 research questions: (1) What are nurses' current attitudes about smart infusion pumps? (2) What do nurses think are the causes of smart infusion pump work arounds? and (3) To whom do nurses turn for smart infusion pump training and troubleshooting? We surveyed a large number of nurses (N = 818) in 3 U.S.-based health care systems to address the research questions above. We assessed nurses' opinions about smart infusion pumps, organizational perceptions, and the reasons for work arounds using a voluntary and anonymous Web-based survey. Using qualitative research methods, we coded open-ended responses to questions about the reasons for work arounds to organize responses into useful categories. The nurses reported widespread satisfaction with smart infusion pumps. However, they reported numerous organizational, cultural, and psychological causes of smart pump work arounds. Of 1029 open-ended responses to the question "why do smart pump work arounds occur?" approximately 44% of the causes were technology related, 47% were organization related, and 9% were related to individual factors. Finally, an overwhelming majority of nurses reported seeking solutions to smart pump problems from coworkers and being trained primarily on the job. Hospitals may significantly improve adherence to smart pump safety features by addressing the nontechnical causes of work arounds and by providing more leadership and formalized training for resolving smart pump-related problems.

  12. Performance of a Solar Heating System with Photovoltaic Thermal Hybrid Collectors and Heat Pump

    DEFF Research Database (Denmark)

    Dannemand, Mark; Furbo, Simon; Perers, Bengt

    2017-01-01

    The energy consumption in buildings accounts for a large part of the World’s CO2 emissions. Much energy is used for appliances, domestic hot water preparation and space heating. In solar heating systems, heat is captured by solar collectors when the sun is shining and used for heating purposes....... In this system, it is possible to have the high performance of the liquid/water heat pump but without the need to install tubes in the ground. The performance of the system with automated energy discharge over several months is evaluated....

  13. Optimal heat rejection pressure in transcritical carbon dioxide air conditioning and heat pump systems

    DEFF Research Database (Denmark)

    Liao, Shengming; Jakobsen, Arne

    1998-01-01

    , the cycles using carbon dioxide as refrigerant will have to operate in the transcritical area. In a transcritical carbon dioxide system, there is an optimal heat rejection pressure that gives a maximum COP. In this paper, it is shown that the value of this optimal heat rejection pressure mainly depends...... on the outlet temperature of the gas cooler, the evaporation temperature and the efficiency of the compressor. General correlations for this optimal heat rejection pressure were derived based on cycle simulations. The correlations presented in this paper provide a basis for designing transcritical carbon...... dioxide air conditioning or heat pump systems and for intelligent controlling such systems....

  14. Integration of large-scale heat pumps in the district heating systems of Greater Copenhagen

    DEFF Research Database (Denmark)

    Bach, Bjarne; Werling, Jesper; Ommen, Torben Schmidt

    2016-01-01

    This study analyses the technical and private economic aspects of integrating a large capacity of electric driven HP (heat pumps) in the Greater Copenhagen DH (district heating) system, which is an example of a state-of-the-art large district heating system with many consumers and suppliers....... The analysis was based on using the energy model Balmorel to determine the optimum dispatch of HPs in the system. The potential heat sources in Copenhagen for use in HPs were determined based on data related to temperatures, flows, and hydrography at different locations, while respecting technical constraints...

  15. Integrated Cabin and Fuel Cell System Thermal Management with a Metal Hydride Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Hovland, V.

    2004-12-01

    Integrated approaches for the heating and cooling requirements of both the fuel cell (FC) stack and cabin environment are critical to fuel cell vehicle performance in terms of stack efficiency, fuel economy, and cost. An integrated FC system and cabin thermal management system would address the cabin cooling and heating requirements, control the temperature of the stack by mitigating the waste heat, and ideally capture the waste heat and use it for useful purposes. Current work at the National Renewable Energy Laboratory (NREL) details a conceptual design of a metal hydride heat pump (MHHP) for the fuel cell system and cabin thermal management.

  16. Final Technical Report for EE0006091: H2Pump Hydrogen Recycling System Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Staudt, Rhonda [H2Pump LLC, Latham, NY (United States)

    2017-02-21

    The objective of this project is to demonstrate the product readiness and to quantify the benefits and customer value proposition of H2Pump’s Hydrogen Recycling System (HRS-100™) by installing and analyzing the operation of multiple prototype 100-kg per day systems in real world customer locations. The data gathered will be used to measure reliability, demonstrate the value proposition to customers, and validate our business model. H2Pump will install, track and report multiple field demonstration systems in industrial heat treating and semi-conductor applications. The customer demonstrations will be used to develop case studies and showcase the benefits of the technology to drive market adoption.

  17. Robust technology and system for management of sucker rod pumping units in oil wells

    Science.gov (United States)

    Aliev, T. A.; Rzayev, A. H.; Guluyev, G. A.; Alizada, T. A.; Rzayeva, N. E.

    2018-01-01

    We propose a technology for calculating the robust, normalized correlation functions of the signal from the force sensor on the rod string attached to the hanger of the sucker rod pumping unit. The robust normalized correlation functions are used to form sets of informative attribute combinations, each of which corresponds to a technical condition of the sucker rod pumping unit. We demonstrate how these sets can be used to solve identification and management problems in the oil production process in real time using inexpensive controllers. The results obtained from using the system on real objects are also presented in this paper. It was determined that the energy saved and prolonged overhaul period substantially increased the cost-effectiveness.

  18. Development of LD pumped 10 J x 10 Hz Nd: Glass slab laser system

    Energy Technology Data Exchange (ETDEWEB)

    Yamanaka, Masanobu; Kanabe, Tadashi; Matsui, Hideki [Osaka Univ., Suita (Japan). Inst. of Laser Engineering] (and others)

    2000-03-01

    As a first step of a driver development for the inertial fusion energy, we are developing a diode-pumped zig-zag Nd: glass slab laser amplifier system which can generate an output of 10 J per pulse at 1053 nm in 10 Hz operation. The water-cooled zig-zag Nd: glass slab is pumped from both sides by 803-nm AlGaAs laser-diode (LD) module; each LD module has an emitting area of 420 mm x 10 mm and two LD modules generated in total 200 kW peak power with 2.5 kW/cm{sup 2} peak intensity at 10 Hz repetition rate. We have obtained in a preliminary experiment a 8.5 J output energy at 0.5 Hz with beam quality of 2 times diffraction limited far-field pattern. (author)

  19. Increasing nuclear safety and operational reliability by upgrading the charging pump mechanical sealing system

    Energy Technology Data Exchange (ETDEWEB)

    Loenhout, Gerard van [Flowserve Corporation, Etten-Leur (Netherlands); Nilsson, Peter [Flowsys Technologies AB, Moelndal (Sweden); Jehander, Magnus [Ringhals AB, Vaeroebacka (Sweden)

    2016-07-01

    For the Ringhals-2 nuclear power plant, three installed centrifugal pumps were designated to have a combined High Head Safety Injection function, as well as a Chemical Volume Control System function. The pumps were originally installed with rubber bellow type mechanical seals, which over time had demonstrated an unreliable sealing performance by displaying high leakages. In 2002, the Ringhals Maintenance engineers initiated to identify a more reliable and robust shaft sealing solution. In 2007, the project was launched and the installation of the first, new mechanical sealing solution took place in the autumn of 2011. In October 2014, these mechanical seals were dismantled and inspected. The inspection confirmed the expected reliability of the new solution.

  20. Solar assisted heat pump system with volume solar collector. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    Sabnis, J.S.; Hickox, W.J.; Drucker, E.E.; Ucar, M.; LaGraff, J.E.

    1978-09-01

    The system uses the attic of the house with a large south facing window as the solar collector. An air-to-water heat pump uses the attic air as a heat source to heat a volume of storage water during the heating season. During the cooling season the attic is ventilated and the heat pump uses the attic air as a heat sink while cooling the storage water. The computer program was developed to include a heat exchanger in the attic which could by-pass the heat pump condenser cooling water, thus permitting direct heat exchange between the attic air and the storage water whenever a favorable temperature existed. The program also accounts for the effect of the incidence angle of insolation and the effect of the number of glass plates on the transmittance and absorptance of the collector and windows. Other refinements include: the use of a sophisticated nighttime setback thermostat, account of internal heat generation and infiltration loss. Among all of the parameter variations, the use of an attic heat exchanger resulted in the maximum savings in the heating/cooling energy consumption of the house. The use of double-glazed windows too, resulted in substantial energy savings. The total energy consumption was found to depend strongly on the infiltration rate. The program was also used to simulate the same system under weather conditions existing at several different geographic areas.

  1. Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings

    DEFF Research Database (Denmark)

    Kjellsson, Elisabeth; Hellström, Göran; Perers, Bengt

    2010-01-01

    -source heat pumps, computer simulations have been carried out with the simulation program TRNSYS. Large differences were found between the system alternatives. The optimal design is when solar heat produces domestic hot water during summertime and recharges the borehole during wintertime. The advantage...... is related to the rate of heat extraction from the borehole as well as the overall design of the system. The demand of electricity may increase with solar recharging, because of the increased operating time of the circulation pumps. Another advantage with solar heat in combination with heat pumps is when...... by recharge from solar heat....

  2. Increasing RES Penetration and Security of Energy Supply by Use of Energy Storages and Heat Pumps in Croatian Energy System

    DEFF Research Database (Denmark)

    Krajačić, Goran; Mathiesen, Brian Vad; Duić, Neven

    2010-01-01

    electricity, heat and transport demands, and including renewable energy, power plants, and combined heat and power production (CHP) for district heating. Using the 2007 energy system the wind power share is increased by two energy storage options: Pumped hydro and heat pumps in combination with heat storages......In this paper integration of wind power generation into the Croatian electricity supply is analysed using available technologies. The starting point is a model of the energy system in Croatia in 2007. Comprehensive hour-by-hour energy system analyses are conducted of a complete system meeting....... The results show that such options can enable an increased penetration of wind power. Using pumped hydro storage (PHS) may increase wind power penetration from 0.5 TWh, for existing PHS installations and up to 6 TWh for very large installations. Using large heat pumps and heat storages in combination...

  3. Optimization of pumping schemes for 160-Gb/s single channel Raman amplified systems

    DEFF Research Database (Denmark)

    Xu, Lin; Rottwitt, Karsten; Peucheret, Christophe

    2004-01-01

    Three different distributed Raman amplification schemes-backward pumping, bidirectional pumping, and second-order pumping-are evaluated numerically for 160-Gb/s single-channel transmission. The same longest transmission distance of 2500 km is achieved for all three pumping methods with a 105-km...

  4. Optimization and thermoeconomics research of a large reclaimed water source heat pump system.

    Science.gov (United States)

    Zhang, Zi-ping; Du, Fang-hui

    2013-01-01

    This work describes a large reclaimed water source heat pump system (RWSHPS) and elaborates on the composition of the system and its design principles. According to the characteristics of the reclaimed water and taking into account the initial investment, the project is divided into two stages: the first stage adopts distributed heat pump heating system and the second adopts the combination of centralized and decentralized systems. We analyze the heating capacity of the RWSHPS, when the phase II project is completed, the system can provide hydronic heating water with the supply and return water temperature of 55°C/15°C and meet the hydronic heating demand of 8 million square meters of residential buildings. We make a thermal economics analysis by using Thermal Economics theory on RWSHPS and gas boiler system, it is known that the RWSHPS has more advantages, compared with the gas boiler heating system; both its thermal efficiency and economic efficiency are relatively high. It provides a reference for future applications of the RWSHPS.

  5. Analysis of a hybrid PV/thermal solar-assisted heat pump system for sports center water heating application

    OpenAIRE

    Bai, Y.; Chow, T. T.; Ménézo, C.; Dupeyrat, P.

    2012-01-01

    International audience; The application of solar energy provides an alternative way to replace the primary source of energy, especially for large-scale installations. Heat pump technology is also an effective means to reduce the consumption of fossil fuels. This paper presents a practical case study of combined hybrid PV/T solar assisted heat pump (SAHP) system for sports center hot water production. The initial design procedure was first presented. The entire system was then modeled with the...

  6. PEnELOPE: a high peak-power diode-pumped laser system for laser-plasma experiments

    Science.gov (United States)

    Siebold, Mathias; Roeser, Fabian; Loeser, Markus; Albach, Daniel; Schramm, Ulrich

    2013-05-01

    We introduce the directly diode-pumped PEnELOPE laser-system which is designed for a pulse energy of 150 J, a repetition rate of 1Hz and a pulse duration of 120 fs. The principle setup of amplifier and stretcher-compressor system as well as the pumping, energy extraction and cooling scheme of the power amplifiers will be reported. In this paper we focus on numerical modeling as well as design studies.

  7. The RD/D opportunities for large air-conditioning and heat-pump systems

    Science.gov (United States)

    MacDonald, M.; Goldenberg, D.; Hudgins, E.

    1982-06-01

    The marketplace factors that constrain a more rapid implementation of energy-conserving heating, ventilating, and air conditioning (HVAC) systems and system operation in commercial buildings are summarized. The focus was on large air conditioning and heat pump equipment. Use of currently available energy-efficient equipment and systems is presently limited by the economic situation of the building owners. Although case histories of energy-efficient buildings highlight the potential of new and existing equipment and systems, the majority of systems and equipment being installed today do not measure up to that potential. The major recommendations deal with developing the market for energy-efficient HVAC systems by reversing existing market forces that promote energy consumption; promoting technical research and educational programs; increasing the number of technical people competent in the area of high-efficiency system application and maintenance.

  8. Analytical expressions for optimum flow rates in evaporators and condensers of heat pumping systems

    Energy Technology Data Exchange (ETDEWEB)

    Granryd, E. [Dept. of Energy Technology, Royal Institute of Technology, KTH, Stockholm (Sweden)

    2010-11-15

    The flow velocities on the air or liquid side of evaporators and condensers in refrigerating or heat pump systems affect the system performance considerably. Furthermore the velocity can often be chosen rather freely without obvious first cost implications. The purpose of the paper is to show analytical relations indicating possible optimum operating conditions. Considering a base case where the design data are known, simple analytical relations are deduced for optimum flow rates that will result in highest overall COP of the system when energy demand for the compressor as well as pumps or fans are included. This optimum is equivalent to the solution for minimum total energy demand of the system for a given cooling load. It is also shown that a different (and higher) flow rate will result in maximum net cooling capacity for a refrigerating system with fixed compressor speed. The expressions can be used for design purposes as well as for checking suitable flow velocities in existing plants. The relations may also be incorporated in algorithms for optimal operation of systems with variable speed compressors. (author)

  9. Study of hybrid power system potential to power agricultural water pump in mountain area

    Science.gov (United States)

    Syuhada, Ahmad; Mubarak, Amir Zaki; Maulana, M. Ilham

    2016-03-01

    As industry and Indonesian economy grow fast, there are a lot of agricultural land has changed into housing and industrial land. This causes the agricultural land moves to mountain area. In mountainous agricultural area, farmers use the water resources of small rivers in the groove of the mountain to irrigate the farmland. Farmers use their power to lift up water from the river to their land which causes inefectivity in the work of the farmers. Farmers who have capital utilize pump to raise water to their land. The only way to use pump in mountain area is by using fuel energy as there is no electricity, and the fuel price in mountain area is very expensive. Based on those reasons it is wise to consider the exploration of renewable energy available in the area such as solar energy, wind energy and hybrid energy. This study analyses the potential of the application of hybrid power plant, which is the combination of solar and wind energy, to power agricultural pump. In this research, the data of wind speed and solar radiation are collected from the measurement of BMKG SMPK Plus Sare. Related to the solar energy, the photovoltaic output power calculation is 193 W with duration of irradiation of 5 hours/day. While for the wind energy, the output power of the wind turbine is 459.84 W with blade diameter of 3 m and blow duration of 7 hours/day. The power of the pump is 558 W with 8 hours of usage, and the water capacity is 2.520 liters/hour for farmland with the area of 15 ha. Based on the analysis result, the designed system will generate electricity of 3.210 kW/year with initial investment of US 14,938.

  10. Effects of cold stratification, sulphuric acid, submersion in hot and ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-07-06

    Jul 6, 2009 ... This study was carried out to determine which pre-treatments should be preferred to overcome dormancy problems of Colutea armena seeds which were collected from three different provenances. Pre-treatments applied to the seeds were submersion in concentrated (98%) sulphuric acid for 30 min,.

  11. Effects of cold stratification, sulphuric acid, submersion in hot and ...

    African Journals Online (AJOL)

    Effects of cold stratification, sulphuric acid, submersion in hot and tap water pretreatments in the greenhouse and open field conditions on germination of bladder-Senna ... This study was carried out to determine which pre-treatments should be preferred to overcome dormancy problems of Colutea armena seeds which were ...

  12. Submersible microbial fuel cell for electricity production from sewage sludge

    DEFF Research Database (Denmark)

    Zhang, Yifeng; Olias, Lola Gonzalez; Kongjan, Prawit

    2010-01-01

    A submersible microbial fuel cell (SMFC) was utilized to treatment of sewage sludge and simultaneous generate electricity. Stable power generation (145±5 mW/m2) was produced continuously from raw sewage sludge for 5.5 days. The corresponding total chemical oxygen demand (TCOD) removal efficiency...

  13. Development of laser diode pumped solid state green laser for the pumping of wavelength tunable laser. 1. Development of single-pass Nd:YAG MOPA system

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Yoichiro; Kato, Masaaki; Oba, Masaki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-06-01

    For the pumping of wavelength tunable laser, a high repetition rate, high average power solid state laser pumped by a high duty laser diode (LD) array has been developed. The solid state laser using Nd:YAG zigzag slab crystals consists of an oscillator and an amplifier. Using this Nd:YAG MOPA system, the maximum fundamental average power of 33 W is obtained. The wavefront distortion of amplified laser beam is within 0.3 wavelength. M{sup 2} measured is about 1.5 which means the laser beam is near diffraction limited. By using nonlinear crystals, fundamental laser radiation is converted to second, third and fourth harmonics. The average power is 15.5 W at 532 nm, 1.2 W at 355 nm and 2.3 W at 266 nm. The beam quality of the second harmonic is good. With the measurement of the laser parameters, it is confirmed that the high repetition rate, high power and high quality second harmonic can be produced by the LD pumped Nd:YAG laser MOPA system. (author)

  14. Fluid Dynamic Analysis of Hand-Pump Infuser and UROMAT Endoscopic Automatic System for Irrigation Through a Flexible Ureteroscope.

    Science.gov (United States)

    Lama, Daniel J; Owyong, Michael; Parkhomenko, Egor; Patel, Roshan M; Landman, Jaime; Clayman, Ralph V

    2018-02-13

    To evaluate the flow characteristics produced by a manual and automated-pump irrigation system connected to a flexible ureteroscope. An in vitro analysis of a manual hand-pump infuser (HP) and the UROMAT Endoscopic Automatic System for Irrigation ® (E.A.S.I.) pump was performed. Standard irrigation tubing was used to connect a three-way valve to a flexible ureteroscope, the irrigation system, and a digital manometer. Flow rate and irrigation pressure measurements were recorded over a 15-minute period using pressure settings of 150 and 200 mm Hg for both irrigation pump systems. Once the HP was inflated to the initial pressure, it was not reinflated over the course of the trial. Data were collected with the working channel unoccupied and with placement of a 200 μm (0.6F) holmium laser fiber, 1.7F nitinol stone retrieval basket, or 2.67F guidewire. The difference in pressure measured at the site of inflow of irrigation to the ureteroscope was significantly greater using the HP compared to the E.A.S.I. pump at pressure settings of 150 mm Hg with and without the use of ureteroscopic instrumentation (p pump systems. The flow rates of irrigation produced by the HP and the E.A.S.I. pump are similar at pressures of 150 and 200 mm Hg irrespective of the occupancy of a ureteroscope's working channel during the first 5-minutes of irrigation. Irrigation pressure at the entry site of the ureteroscope is subject to significant variability with use of the HP compared to the E.A.S.I. pump irrigation system.

  15. Conessine as a novel inhibitor of multidrug efflux pump systems in Pseudomonas aeruginosa.

    Science.gov (United States)

    Siriyong, Thanyaluck; Srimanote, Potjanee; Chusri, Sasitorn; Yingyongnarongkul, Boon-Ek; Suaisom, Channarong; Tipmanee, Varomyalin; Voravuthikunchai, Supayang Piyawan

    2017-08-14

    Holarrhena antidysenterica has been employed as an ethnobotanical plant for the treatment of dysentery, diarrhoea, fever, and bacterial infections. Biological activities of the principle compound, conessine including anti-diarrhoea and anti-plasmodial effects were documented. Our previous study reported potency of Holarrhena antidysenterica extract and conessine as resistance modifying agents against extensively drug-resistant Acinetobacter baumannii. This study aimed to investigate (i) whether conessine, a steroidal alkaloid compound, could act as a resistance modifying agent against multidrug-resistant Pseudomonas aeruginosa, and (ii) whether MexAB-OprM efflux pump involved in the mechanism. Conessine combined with various antibiotics were determined for synergistic activity against P. aeruginosa PAO1 strain K767 (wild-type), K1455 (MexAB-OprM overexpressed), and K1523 (MexB deletion). H33342 accumulation assay was used to evaluate efflux pump inhibition while NPN uptake assay was assessed membrane permeabilization. Conessine significantly reduced MICs of all antibiotics by at least 8-fold in MexAB-OprM overexpressed strain. The levels were comparable to those obtained in wild-type strain for cefotaxime, levofloxacin, and tetracycline. With erythromycin, novobiocin, and rifampicin, MICs were 4- to 8-fold less than MICs of the wild-type strain. Loss of MexAB-OprM due to deletion of mexB affected susceptibility to almost all antibiotics, except novobiocin. Synergistic activities between other antibiotics (except novobiocin) and conessine observed in MexB deletion strain suggested that conessine might inhibit other efflux systems present in P. aeruginosa. Inhibition of H33342 efflux in the tested strains clearly demonstrated that conessine inhibited MexAB-OprM pump. In contrast, the mode of action as a membrane permeabilizer was not observed after treatment with conessine as evidenced by no accumulation of 1-N-phenylnaphthylamine. The results suggested that

  16. Large-scale heat pumps in sustainable energy systems: System and project perspectives

    Directory of Open Access Journals (Sweden)

    Blarke Morten B.

    2007-01-01

    Full Text Available This paper shows that in support of its ability to improve the overall economic cost-effectiveness and flexibility of the Danish energy system, the financially feasible integration of large-scale heat pumps (HP with existing combined heat and power (CHP plants, is critically sensitive to the operational mode of the HP vis-à-vis the operational coefficient of performance, mainly given by the temperature level of the heat source. When using ground source for low-temperature heat source, heat production costs increases by about 10%, while partial use of condensed flue gasses for low-temperature heat source results in an 8% cost reduction. Furthermore, the analysis shows that when a large-scale HP is integrated with an existing CHP plant, the projected spot market situation in The Nordic Power Exchange (Nord Pool towards 2025, which reflects a growing share of wind power and heat-supply constrained power generation electricity, further reduces the operational hours of the CHP unit over time, while increasing the operational hours of the HP unit. In result, an HP unit at half the heat production capacity as the CHP unit in combination with a heat-only boiler represents as a possibly financially feasible alternative to CHP operation, rather than a supplement to CHP unit operation. While such revised operational strategy would have impacts on policies to promote co-generation, these results indicate that the integration of large-scale HP may jeopardize efforts to promote co-generation. Policy instruments should be designed to promote the integration of HP with lower than half of the heating capacity of the CHP unit. Also it is found, that CHP-HP plant designs should allow for the utilization of heat recovered from the CHP unit’s flue gasses for both concurrent (CHP unit and HP unit and independent operation (HP unit only. For independent operation, the recovered heat is required to be stored. .

  17. Progress in the development of a transcutaneously powered axial flow blood pump ventricular assist system.

    Science.gov (United States)

    Parnis, S M; Conger, J L; Fuqua, J M; Jarvik, R K; Inman, R W; Tamez, D; Macris, M P; Moore, S; Jacobs, G; Sweeney, M J; Frazier, O H

    1997-01-01

    Development of the Jarvik 2000 intraventricular assist system for long-term support is ongoing. The system integrates the Jarvik 2000 axial flow blood pump with a microprocessor based automatic motor controller to provide response to physiologic demands. Nine devices have been evaluated in vivo (six completed, three ongoing) with durations in excess of 26 weeks. Instrumented experiments include implanted transit-time ultrasonic flow probes and dual micromanometer LV/AoP catheters. Treadmill exercise and heart pacing studies are performed to evaluate control system response to increased heart rates. Pharmacologically induced cardiac dysfunction studies are performed in awake and anesthetized calves to demonstrate control response to simulated heart failure conditions. No deleterious effects or events were encountered during any physiologic studies. No hematologic, renal, hepatic, or pulmonary complications have been encountered in any study. Plasma free hemoglobin levels of 7.0 +/- 5.1 mg/dl demonstrate no device related hemolysis throughout the duration of all studies. Pathologic analysis at explant showed no evidence of thromboembolic events. All pump surfaces were free of thrombus except for a minimal ring of fibrin, (approximately 1 mm) on the inflow bearing. Future developments for permanent implantation will include implanted physiologic control systems, implanted batteries, and transcutaneous energy and data transmission systems.

  18. Compact interior heat exchangers for CO{sub 2} mobile heat pumping systems

    Energy Technology Data Exchange (ETDEWEB)

    Hafner, Armin

    2003-07-01

    The natural refrigerant carbon dioxide (CO{sub 2}) offers new possibilities for design of flexible, efficient and environmentally safe mobile heat pumping systems. As high-efficient car engines with less waste heat are developed, extra heating of the passenger compartment is needed in the cold season. A reversible transcritical CO{sub 2} system with gliding temperature heat rejection can give high air delivery temperature which results in rapid heating of the passenger compartment and rapid defogging or defrosting of windows. When operated in cooling mode, the efficiency of transcritical CO{sub 2} systems is higher compared to common (HFC) air conditioning systems, at most dominant operating conditions. Several issues were identified for the design of compact interior heat exchangers for automotive reversible CO{sub 2} heat pumping systems. Among theses issues are: (1) Refrigerant flow distribution, (2) Heat exchanger fluid flow circuiting, (3) Air temperature uniformity downstream of the heat exchanger, (4) Minimization of temperature approach, (5) Windshield flash fogging due to retained water inside the heat exchanger, (6) Internal beat conduction in heating mode operation, and (7) Refrigerant side pressure drop In order to provide a basis for understanding these issues, the author developed a calculation model and set up a test facility and investigated different prototype heat exchangers experimentally.

  19. Design and Evaluation of a Photovoltaic/Thermal-Assisted Heat Pump Water Heating System

    Directory of Open Access Journals (Sweden)

    Huan-Liang Tsai

    2014-05-01

    Full Text Available This paper presents the design, modelling and performance evaluation of a photovoltaic/thermal-assisted heat pump water heating (PVTA-HPWH system. The cooling effect of a refrigerant simultaneously enhances the PVT efficiency and effectively improves the coefficient of performance (COP of the HPWH system. The proposed model was built in the MATLAB/Simulink environment by considering the reciprocal energy exchange between a PVT evaporator and a HPWH system. In addition, the power consumption needs of the HPWH are provided by the PV electricity using a model-based control methodology. System performance is evaluated through a real field test. The results have demonstrated the power autarchy of the proposed PVTA-HPWH system with better PVT efficiency and COP. In addition, the good agreement between the model simulation and the experimental measurements demonstrate the proposed model with sufficient confidence.

  20. Experimental Study of the Performance of Air Source Heat Pump Systems Assisted by Low-Temperature Solar-Heated Water

    Directory of Open Access Journals (Sweden)

    Jinshun Wu

    2013-01-01

    Full Text Available Due to the low temperatures, the heating efficiency of air source heat pump systems during the winter is very low. To address this problem, a low-temperature solar hot water system was added to a basic air source heat pump system. Several parameters were tested and analyzed. The heat collection efficiency of the solar collector was analyzed under low-temperature conditions. The factors that affect the performance of the heat pumps, such as the fluid temperature, pressure, and energy savings, were analyzed for cases where the solar energy auxiliary heat pump and the air source heat pump are used independently. The optimal heating temperature and the changes in the fluid temperature were determined. The influence of the compression ratio and the coefficient of performance (COP were investigated theoretically. The results revealed the parameters that are important to the performance of the system. Several measures for improving the COP of the heat pump units are provided for other applications and future research.

  1. A Control Method to Balance the Efficiency and Reliability of a Time-Delayed Pump-Valve System

    Directory of Open Access Journals (Sweden)

    Zhounian Lai

    2016-01-01

    Full Text Available The efficiency and reliability of pumps are highly related to their operation conditions. The concept of the optimization pump operation conditions is to adjust the operation point of the pump to obtain higher reliability at the cost of lower system efficiency using a joint regulation of valve and frequency convertor. This paper realizes the control of the fluid conveying system based on the optimization results. The system is a nonlinear Multi-Input Multioutput (MIMO system with time delays. In this paper, the time delays are separated from the system. The delay-free system is linearized using input-output linearization and controlled using a sliding mode method. A modified Smith predictor is used to compensate time delays of the system. The control strategy is validated to be effective on the test bench. The comparison of energy consumption and operation point deviation between conventional speed regulation and the new method is presented.

  2. Research and development on super heat pump energy accumulation system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-06-01

    This is the final report on research and development of super heat pump energy accumulation system, which has been carried out from FY 1985 to 1992. It describes outline of the research and development program, R and D results, final evaluation methodology, evaluation of the R and D, proposals for the commercialization, and so on. The super high performance compression heat pumps are technically evaluated for highly efficient type (for heating, and cooling and heating), high temperature type (utilizing high temperature heat source, and low temperature heat source), working fluids (alcohol-based and nonalcohol-based), stainless steel plate fin type heat exchanger, EHD heat exchanger, and so on. The other techniques evaluated include those for chemical heat storage, combined systems, plant simulation, and systemization. The evaluation works are also directed to the economic and environmental aspects. Finally, the R and D themes are proposed to leap over various hurdles, e.g., reliability and economic viability, for the eventual commercialization of the energy accumulation system. (NEDO)

  3. Exergy performance analysis of the conceptual district energy network system with heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seung Won; Chung, Ha Seung [Hongik University, Seoul (Korea, Republic of); Kim, Min Sung [Korea Institute of Energy Research, Daejeon (Korea, Republic of)

    2014-08-15

    To increase the efficiency of a district heating system, we propose a district energy network concept which combines several heating resources with additional electric heat pump and thermal energy storage. With help of thermal energy storage, a heat pump can be operated at maximum efficiency at all the time. Electricity generated with less CO{sub 2} emission makes the proposed system much more environmentally friendly. Even though the proposed concept can be applied to any given situation, a specific target area was chosen to show the effectiveness of the newly proposed energy network concept more clearly. Several constraints were applied for the selection process and a simplified model used for quantitative comparison between the existing and the developed concept. Exergy analysis showed the increased performance of proposed energy network system. The result showed that the newly proposed concept generates less CO{sub 2} emission by 46% at maximum compared to the existing system. By using additional renewable energy sources, we can reduce CO{sub 2} emission even further.

  4. Performance Testing of a Liquid Metal Pump for In-Space Power Systems

    Science.gov (United States)

    Polzin, Kurt

    2011-01-01

    Fission surface power (FSP) systems could be used to provide power on the surface of the moon, Mars, or other planets and moons of our solar system. Fission power systems could provide excellent performance at any location, including those near the poles or other permanently shaded regions, and offer the capability to provide on demand power at any time, even at large distances from the sun. Fission-based systems also offer the potential for outposts, crew and science instruments to operate in a power-rich environment. NASA has been exploring technologies with the goal of reducing the cost and technical risk of employing FSP systems. A reference 40 kWe option has been devised that is cost-competitive with alternatives while providing more power for less mass anywhere on the lunar surface. The reference FSP system is also readily extensible for use on Mars, where it would be capable of operating through global dust storms and providing year-round power at any Martian latitude. Detailed development of the FSP concept and the reference mission are documented in various other reports. The development discussed in this paper prepares the way for testing of the Technology Demonstration Unit (TDU), which is a 10 kWe end-to-end test of FSP technologies intended to raise the entire FSP system to technology readiness level (TRL) 6. The Early Flight Fission Test Facility (EFF-TF) was established by NASA s Marshall Space Flight Center (MSFC) to provide a capability for performing hardware-directed activities to support multiple in-space nuclear reactor concepts by using a nonnuclear test methodology. This includes fabrication and testing at both the module/component level and at near prototypic reactor components and configurations allowing for realistic thermal-hydraulic evaluations of systems. The liquid-metal pump associated with the FSP system must be compatible with the liquid NaK coolant and have adequate performance to enable a viable flight system. Idaho National

  5. Hardware and software system for monitoring oil pump operation in power high-voltage transformers

    Directory of Open Access Journals (Sweden)

    Михайло Дмитрович Дяченко

    2017-07-01

    Full Text Available The article considers the basic prerequisites for the creation of an automated monitoring system for oil pumps of high-voltage transformers. This is due to the fact that the long operation of oil pumps results in deterioration and destruction of bearings, rubbing of the rotor, breakage and damage to the impeller, leakage, etc., which inevitably causes a significant decrease in the insulating properties of the transformer oil and leads to expenditures for its further recovery. False triggerings of gas protection sometimes occur. Continuous operation of the electric motor also requires additional equipment to protect the motor itself from various emergency situations, such as a short in the stator winding, a housing breakdown, an incomplete phase mode, etc. The use of stationary systems provides: diagnosing defects at an early stage of their development, increasing the reliability and longevity of the equipment components, increasing the overhaul period, decreasing the number of emergency stops, and adjusting the schedule of preventative maintenance. The basic principles of identification of the damaged part of the oil pump are given, the hardware and algorithmic solutions are considered in the work. The full-scale tests of the model sample on the power transformer of the high-voltage substation confirmed the assumption of the possibility of detecting the damaged unit separating it from the rest connected in one mechanical structure. A detailed analysis of the operation of each of the units is carried out by means of the general substation switchboard and displayed as graphs, diagrams and text messages. When the limit values of vibration are reached, faults in the operation of the unit are detected, the overlimit current values, a warning alarm is activated, and the command to disconnect the damaged unit is issued. The optimal solution for the organization of the information collection system using the principle of sensor networks, but combined

  6. Developing a System for Integraded Automatic Control of Mutiple Infusion Pumps : The Multiplex infusion system

    NARCIS (Netherlands)

    Doesburg, Frank

    2013-01-01

    Most errors in ICUs are related to intravenous (IV) therapy. Previous studies suggested that hard to operate infusion pumps and the high cognitive workload for ICU nurses contribute to these errors. Conventional IV therapy requires separate lumens for incompatible IV drugs. This often requires the

  7. Air-Source Integrated Heat Pump System Development – Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ally, Moonis R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Uselton, R. B. [Lennox Industries, Inc., Knoxville, TN (United States)

    2017-07-01

    Between October 2007 and September 2017, Oak Ridge National Laboratory (ORNL) and Lennox Industries, Inc. (Lennox) engaged in a Cooperative Research and Development Agreement (CRADA) to develop an air-source integrated heat pump (AS-IHP) system for the US residential market. The Lennox AS-IHP concept consisted of a high-efficiency air-source heat pump (ASHP) for space heating and cooling services and a separate heat pump water heater/dehumidifier (WH/DH) module for domestic water heating and dehumidification (DH) services. A key feature of this system approach with the separate WH/DH is capability to pretreat (i.e., dehumidify) ventilation air and dedicated whole-house DH independent of the ASHP. Two generations of laboratory prototype WH/DH units were designed, fabricated, and lab tested. Performance maps for the system were developed using the latest research version of the US Department of Energy/ORNL heat pump design model (Rice 1992; Rice and Jackson 2005; Shen et al. 2012) as calibrated against the lab test data. These maps served as the input to TRNSYS (Solar Energy Laboratory et al. 2010) to predict annual performance relative to a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (i.e., a combination of an ASHP with a seasonal energy efficiency ratio (SEER) of 13 and resistance water heater with an energy factor (EF) of 0.9). Predicted total annual energy savings (based on use of a two-speed ASHP and the second-generation WH/DH prototype for the AS-IHP), while providing space conditioning, water heating, and dehumidification for a tight, well-insulated 2600 ft2 (242 m2) house at three US locations, ranged from 33 to 36%, averaging 35%, relative to the baseline system. The lowest savings were seen at the cold-climate Chicago location. Predicted energy use for water heating was reduced by about 50 to 60% relative to a resistance WH.

  8. Requirements Analysis Study for Master Pump Shutdown System Project Development Specification [SEC 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    BEVINS, R.R.

    2000-03-24

    This document has been updated during the definitive design portion of the first phase of the W-314 Project to capture additional software requirements and is planned to be updated during the second phase of the W-314 Project to cover the second phase of the Project's scope. The objective is to provide requirement traceability by recording the analysis/basis for the functional descriptions of the master pump shutdown system. This document identifies the sources of the requirements and/or how these were derived. Each requirement is validated either by quoting the source or an analysis process involving the required functionality, performance characteristics, operations input or engineering judgment.

  9. An investigation of a jet-pump thermal (ice) storage system powered by low-grade heat

    OpenAIRE

    Worall, Mark

    2001-01-01

    This thesis investigates a novel combination of a jet-pump refrigeration cycle and a thermal (ice) storage (TIS) system that could substantially reduce the electrical energy requirements attributable to comfort cooling.Two methods of TIS were identified; spray ice TIS would use evaporative freezing to store ice on a vertical surface,and encapsulated ice TIS would freeze a bed of encapsulated elements by sublimation freezing.Thestudy also investigates jet-pump refrigeration at partload and a ...

  10. Study on global performances and mooring-induced damping of a semi-submersible

    Science.gov (United States)

    Xiong, Ling-zhi; Yang, Jian-min; Lv, Hai-ning; Zhao, Wen-hua; Kou, Yu-feng

    2016-10-01

    The harsh environmental conditions bring strong nonlinearities to the hydrodynamic performances of the offshore floating platforms, which challenge the reliable prediction of the platform coupled with the mooring system. The present study investigates a typical semi-submersible under both the operational and the survival conditions through numerical and experimental methods. The motion responses, the mooring line tensions, and the wave loads on the longitudinal mid-section are investigated by both the fully non-linearly coupled numerical simulation and the physical experiment. Particularly, in the physical model test, the wave loads distributed on the semi-submersible's mid-section were measured by dividing the model into two parts, namely the port and the starboard parts, which were rigidly connected by three six-component force transducers. It is concluded that both the numerical and physical model can have good prediction of the semi-submersible's global responses. In addition, an improved numerical approach is proposed for the estimation of the mooring-induced damping, and is validated by both the experimental and the published results. The characteristics of the mooring-induced damping are further summarized in various sea states, including the operational and the survival environments. In order to obtain the better prediction of the system response in deep water, the mooring-induced damping of the truncated mooring lines applied in the physical experiment are compensated by comparing with those in full length. Furthermore, the upstream taut and the downstream slack mooring lines are classified and investigated to obtain the different mooring line damping performances in the comparative study.

  11. Municipal water-based heat pump heating and/or cooling systems: Findings and recommendations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bloomquist, R.G. [Washington, State Univ., Pullman, WA (United States); Wegman, S. [South Dakota Utilities Commission (United States)

    1998-04-01

    The purpose of the present work was to determine if existing heat pump systems based on municipal water systems meet existing water quality standards, to analyze water that has passed through a heat pump or heat exchanger to determine if corrosion products can be detected, to determine residual chlorine levels in municipal waters on the inlet as well as the outlet side of such installations, to analyses for bacterial contaminants and/or regrowth due to the presence of a heat pump or heat exchanger, to develop and suggest criteria for system design and construction, to provide recommendations and specifications for material and fluid selection, and to develop model rules and regulations for the installation, operation, and monitoring of new and existing systems. In addition, the Washington State University (WSU) has evaluated availability of computer models that would allow for water system mapping, water quality modeling and system operation.

  12. Pumps; Pumpen

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, H. [Gesellschaft fuer Praktische Energiekunde e.V., Muenchen (Germany). Forschungsstelle fuer Energiewirtschaft; Hellriegel, E. [Gesellschaft fuer Praktische Energiekunde e.V., Muenchen (Germany). Forschungsstelle fuer Energiewirtschaft; Pfitzner, G. [Gesellschaft fuer Praktische Energiekunde e.V., Muenchen (Germany). Forschungsstelle fuer Energiewirtschaft

    1994-11-01

    The technical features of commercial pump types are described with regard to their technical, energy-related and economic parameters, and characteristic data are presented in the form of data sheets. This is to provide a basis for a comparative assessment of different technologies and technical variants. The chapter `System specifications` describes the various fields of application of pumps and the resulting specific requirements. The design and function of the different pump types are described in `Technical description`. `System and plant description dscribes the design and adaptation of pumps, i.e. the adaptation of the plant data to the system requirements. `Data compilation` provides a survey of the types and systematics of the compiled data as well as a decision aid for selecting the pumps best suited to the various applications. The `Data sheet` section describes the structure and handling of the data sheets as well as the data contained therein. The data sheets are contained in the apapendix of this report. The section `General analysis` compares typical technical, energy-related and economic characteristics of the different pump types. This is to enable a rough comparison of pump types and to facilitate decisions. The chapter `Example` illustrates the use of the data sheets by means of a selected example. (orig./GL) [Deutsch] Die vorliegende Arbeit hat zum Ziel, Technik seriengefertigter und marktgaengiger Pumpen in typisierter Form hinsichtlich ihrer technischen, energetischen und wirtschaftlichen Parameter zu beschreiben und ihre charakteristischen Kennwerte in Datenblaettern abzubilden. Damit wird ein grundlegendes Instrument fuer die vergleichende Beurteilung unterschiedlicher Techniken bzw. Technikvarianten hinsichtlich energetischer und wirtschaftlicher Kriterien geschaffen. Im Abschnitt `Systemanforderungen` erfolgt die Beschreibung der einzelnen Anwendungsbereiche fuer Pumpen mit den speziellen daraus resultierenden Anforderungen. Der Aufbau und

  13. REMOTE CONTROLLING OF AN AGRICULTURAL PUMP SYSTEM BASED ON THE DUAL TONE MULTI-FREQUENCY (DTMF TECHNIQUE

    Directory of Open Access Journals (Sweden)

    BEZA N. GETU

    2015-10-01

    Full Text Available In modern days, as a result of advances in technology, human beings are interested to remotely control different systems and applications. In this work, telephone signalling technique using Dual Tone Multi-Frequency (DTMF signalling, is used to control switching of electrical loads such as agricultural pumps located in remote areas. A DTMF tone command sent from a transmitting fixed or mobile phone terminal will be used to SWITCH ON/OFF the motors used to pump water for agricultural fields. A processing electronic system at the receiving side is designed to interpret the tone commands and sends an appropriate signal to the motor driving circuit to complete the pump switching states. In the design methodology, it is possible to control several water pumps distributed in a certain agricultural site, however, in this work we considered four pumps and the paper presents the complete electronic design and simulation results at the different stages of the design. The electronic design is based on discrete passive and active electronic components and the system is tested and simulated using Multism program. The results of the simulation show that the design is capable of controlling the switching state of the motors. For a certain DTMF command, it is possible to switch ON/OFF a specific motor pump or all of the four motors.

  14. Study on Operating Performance of Stirling Engine-Driven Vapor Compression Heat Pump System

    Science.gov (United States)

    Kagawa, Noboru

    Stirling engines have many unique advantages including higher thermal efficiencies, preferable exhaust gas characteristics, multi-fuel usage, and low noise and vibration. On the other hand, heat pump systems are very attractive for space heating and cooling, and industrial usage. There are several environmental merits of Stirling driven vapor compression (SDVC) systems. A design method for the SDVC, which is based on mathematical methods for Stirling and Ranking cycles, has been developed. The attractive SDVC performance using conventional and alternative refrigerants was shown. From the calculated Total Equivalent Warming Impact (TEWI) and operating costs, it became clear that the SDVC system with the alternative refrigerant has a higher potential as the future air-conditioning system.

  15. Intelligent Balanced Device and its Sensing System for Beam Pumping Units

    Directory of Open Access Journals (Sweden)

    Hangxin WEI

    2014-11-01

    Full Text Available In order to save the energy of the beam pumping unit, the intelligent balanced device was developed. The device can adjust the position of the balanced-block automatically by the single chip microcomputer controller, and the fuzzy PD control algorithm was used to control the servo motor of the device. Since some signals should be inputted into the intelligent balanced device to calculate the balanced index of the pumping unit, the signals sensing system were designed. The sensing system includes the electric current sensor and voltage sensor of the main motor, the displacement sensor and the force sensor of the horse head. The sensing network has three layers: slave station, relay station and master station. The data transmission between them is based on ZigBee and GPRS method which can adapt the environment of the oil field. The results of application show that the intelligent balanced device and its sensing system can have the effect of reducing the power consumption, working reliability and communication efficiently.

  16. Chemiluminometric determination of carvedilol in a multi-pumping flow system.

    Science.gov (United States)

    Pires, Cherrine K; Marques, Karine L; Santos, João L M; Lapa, Rui A S; Lima, José L F C; Zagatto, Elias A G

    2005-12-15

    In this work a simple, fast, sensitive and selective flow-based procedure for the chemiluminometric determination of carvedilol, a recent non-cardioselective beta-blocker with noteworthy antioxidant activity, is proposed. The developed methodology takes advantage of the antioxidant capacity of carvedilol to inhibit the chemiluminescence response resulting from the oxidation of luminol by hypochlorite, by acting as a hypochlorite scavenger. The analytical process was implemented in a multi-pumping flow system that employs multiple solenoid actuated micro-pumps as the only active components. These acted as solution insertion, propelling and commuting units assuring an easily controlled, low cost, compact and reliable analytical system. A linear working range for carvedilol concentrations ranging from 1.2x10(-7) to 3.0x10(-6)moll(-1) (r>0.999, n=6), was obtained, with a detection limit of 8.7x10(-9)moll(-1). The system handles about 65 samples per hour yielding precise results (R.S.D.<1.3%, n=10). Recoveries within 95 and 104% were obtained.

  17. Modeling and Performance Improvement of the Constant Power Regulator Systems in Variable Displacement Axial Piston Pump

    Directory of Open Access Journals (Sweden)

    Sung Hwan Park

    2013-01-01

    Full Text Available An irregular performance of a mechanical-type constant power regulator is considered. In order to find the cause of an irregular discharge flow at the cut-off pressure area, modeling and numerical simulations are performed to observe dynamic behavior of internal parts of the constant power regulator system for a swashplate-type axial piston pump. The commercial numerical simulation software AMESim is applied to model the mechanical-type regulator with hydraulic pump and simulate the performance of it. The validity of the simulation model of the constant power regulator system is verified by comparing simulation results with experiments. In order to find the cause of the irregular performance of the mechanical-type constant power regulator system, the behavior of main components such as the spool, sleeve, and counterbalance piston is investigated using computer simulation. The shape modification of the counterbalance piston is proposed to improve the undesirable performance of the mechanical-type constant power regulator. The performance improvement is verified by computer simulation using AMESim software.

  18. Modeling and performance improvement of the constant power regulator systems in variable displacement axial piston pump.

    Science.gov (United States)

    Park, Sung Hwan; Lee, Ji Min; Kim, Jong Shik

    2013-01-01

    An irregular performance of a mechanical-type constant power regulator is considered. In order to find the cause of an irregular discharge flow at the cut-off pressure area, modeling and numerical simulations are performed to observe dynamic behavior of internal parts of the constant power regulator system for a swashplate-type axial piston pump. The commercial numerical simulation software AMESim is applied to model the mechanical-type regulator with hydraulic pump and simulate the performance of it. The validity of the simulation model of the constant power regulator system is verified by comparing simulation results with experiments. In order to find the cause of the irregular performance of the mechanical-type constant power regulator system, the behavior of main components such as the spool, sleeve, and counterbalance piston is investigated using computer simulation. The shape modification of the counterbalance piston is proposed to improve the undesirable performance of the mechanical-type constant power regulator. The performance improvement is verified by computer simulation using AMESim software.

  19. Geothermal Heat Pump System for New Student Housing Project at the University at Albany Main Campus

    Energy Technology Data Exchange (ETDEWEB)

    Lnu, Indumathi [Univ. of Albany, NY (United States)

    2015-08-27

    University at Albany successfully designed, constructed and is operating a new student housing building that utilizes ground source heat pump (GSHP) for heating and cooling the entire 191,500SF building. The installed system consists of a well field with 150 bores, 450 feet deep and (189) terminal heat pump units for a total capacity of 358 Tons cooling and 4,300 MBtu/h heating. The building opened in Fall 2012. The annual energy use and cost intensity of the building, after the changes made during the first 2 years’ of operation is 57kBtu/SF/Year and $1.30/SF/Year respectively. This is approximately 50% lower than the other residential quads on campus, despite the fact that the quads are not air-conditioned. The total project cost from design through 3-years of operations is approximately $6 Million, out of which $5.7 Million is for construction of the GSHP system including the well field. The University received a $2.78 Million grant from the Department of Energy. The estimated utility cost savings, compared to a baseline building with conventional HVAC system, is approximately $185,000. The estimated simple payback, after grant incentives, is 15 years. Additionally, the project has created 8.5FTE equivalent jobs.

  20. A preliminary study on the development of electronic pump system using Arduino controller

    Science.gov (United States)

    Salleh, Mohd Sharil; Miskon, Azizi; Hashim, Fakroul Ridzuan

    2018-02-01

    The implications of treatment using hemodialysis machine and equipment remain speculative. Most studies, case reviews and medical surveys have shown statistics of side effects of hypertension while undergo a treatment using hemodialysis machine. Therefore, a specific action must be taken to prevent the effects of hypertension during treatment especially using hemodialysis machine. In order to reduce this matter in terms of frequency of hypertension while undergo hemodialysis treatment, many approach have been undertaken for improvement. For the beginning, this project reviews the technique of controlling instantaneous blood pressure for normal and hypertension stage and describe the challenges faced by a researcher during experiment to match human stability. The methodology used in this project is to develop one electronics pump system using Arduino controller for transferring liquid (a tap water) from a tank to another tank. The liquid flow rate was measured by using flow sensor where it located at input and output part. This project has decided to focus on flow rate range from 300 mL/min to 900 mL/min. Results shows an efficiency for speed 30 is 97.96%, speed 50 is 100.15%, speed 130 is 99.54% and speed 200 is 99.87%. A range of efficiency for this preliminary study on the development of Electronic Pump System are from 97.96% to 100.15%. In addition, analysis and simulation of the system delivers a better performance efficiency.

  1. Development of an osmotic pump system for controlled delivery of diclofenac sodium.

    Science.gov (United States)

    Emara, L H; Taha, N F; Badr, R M; Mursi, N M

    2012-10-01

    Based on an elementary osmotic pump, controlled release systems of diclofenac sodium (DS) were designed to deliver the drug in a zero-order release pattern. Osmotic pump tablets containing 100 mg DS were prepared and coated with either semipermeable (SPM) or microporous (PM) membranes. The tablet coats were composed of hydrophobic triacetin (TA) or hydrophilic polyethylene glycol 400 (PEG 400) incorporated in cellulose acetate (CA) solution, for SPM and PM, respectively. Variable tablet core compositions such as swelling polymers (PEO and HPMC) and osmotic agents (lactose, NaCl, and KCl) were studied. An optimized, sensitive and well controlled in vitro release design, based on the flow-through cell (FTC), was utilized to discriminate between preparations. The results revealed that the presence of PEG 400 in the coating membrane accelerated the drug release rate, while TA suppressed the release rate of DS. In the case of SPM, the amount of DS released was inversely proportional to the membrane thickness, where 5% (w/w) weight gain gave a higher DS release rate than 10% (w/w). Results of different tablet core compositions revealed that the release rate of DS decreased as PEO molecular weight increased. HPMC K15M showed the lowest DS release rate. The presence of lactose, KCl, or NaCl pronouncedly affected DS release rate depending on polymer type in the core. Scanning electron microscopy (SEM) confirmed formation of pores in the membrane that accounts for faster DS release rate. These results revealed that DS could be formulated as an osmotic pump system with a prolonged, zero-order release pattern.

  2. Heat transfer analysis of underground U-type heat exchanger of ground source heat pump system.

    Science.gov (United States)

    Pei, Guihong; Zhang, Liyin

    2016-01-01

    Ground source heat pumps is a building energy conservation technique. The underground buried pipe heat exchanging system of a ground source heat pump (GSHP) is the basis for the normal operation of an entire heat pump system. Computational-fluid-dynamics (CFD) numerical simulation software, ANSYS-FLUENT17.0 have been performed the calculations under the working conditions of a continuous and intermittent operation over 7 days on a GSHP with a single-well, single-U and double-U heat exchanger and the impact of single-U and double-U buried heat pipes on the surrounding rock-soil temperature field and the impact of intermittent operation and continuous operation on the outlet water temperature. The influence on the rock-soil temperature is approximately 13 % higher for the double-U heat exchanger than that of the single-U heat exchanger. The extracted energy of the intermittent operation is 36.44 kw·h higher than that of the continuous mode, although the running time is lower than that of continuous mode, over the course of 7 days. The thermal interference loss and quantity of heat exchanged for unit well depths at steady-state condition of 2.5 De, 3 De, 4 De, 4.5 De, 5 De, 5.5 De and 6 De of sidetube spacing are detailed in this work. The simulation results of seven working conditions are compared. It is recommended that the side-tube spacing of double-U underground pipes shall be greater than or equal to five times of outer diameter (borehole diameter: 180 mm).

  3. New methods for the identification of efflux mediated MDR bacteria, genetic assessment of regulators and efflux pump constituents, characterization of efflux systems and screening for inhibitors of efflux pumps

    DEFF Research Database (Denmark)

    Viveiros, M; Martins, M; Couto, I

    2008-01-01

    We have developed a number of methods that identify efflux pump mediated multi-drug resistant bacteria, characterize efflux systems and screen for inhibitors of efflux pumps. These approaches were complemented by the quantification of the expression of genes that regulate and code for constituent...

  4. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  5. Gas Engine-Driven Heat Pump Chiller for Air-Conditioning and Hot Water Supply Systems

    Science.gov (United States)

    Fujita, Toshihiko; Mita, Nobuhiro; Moriyama, Tadashi; Hoshino, Norimasa; Kimura, Yoshihisa

    A gas engine-driven heat pump (GHP) uses a natural gas-or LPG-powered engine to drive the compressor in a vapor-compression refrigeration cycle. The GHP has the benefits of being able to use the fuel energy effectively by recovering waste heat from the engine jacket coolant and exhaust gas and also to keep high efficiency even at part-load operation by varying the engine speed with relative ease. Hence, energy-efficient heat source systems for air-conditioning and hot water supply may be constructed with GHP chillers in place of conventional electrical-driven heat pump chillers. GHPs will necessarily contribute to the peak shaving of electrical demand in summer. In this study, the performance characteristics of a 457kW GHP chiller have been investigated by a simulation model analysis, for both cooling and heating modes. From the results of the analysis, it has been found that the part-load characteristics of the GHP chiller are fairly well. The evaluation of the heat source systems using GHP chillers will be described in Part 2.

  6. Normalization of the energy efficiency in pumping systems; Normalizacion de eficiencia energetica en sistemas de bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R.A.; Buendia Dominguez, E.H. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1995-12-31

    The Instituto de Investigaciones Electricas (IIE), supporting the Comision Nacional para el Ahorro de Energia (CONAE) has prepared the preliminary project of the norm of energetic efficiency for pumping systems, specifically for the agricultural sector. This document has complied with the necessary formalities for the issue of a norm and is about to be published as a Mexican Official Norm of energetic efficiency. In this paper mention is made of the results in the analysis of the pumping systems in operation, the energy saving, as well as the economic evaluation that sustain the norm project, indicating besides the environmental impact that its implantation will have. [Espanol] El Instituto de Investigaciones Electricas (IIE) apoyando a la Comision Nacional para el Ahorro de Energia (CONAE) ha elaborado el anteproyecto de norma de eficiencia energetica en sistemas de bombeo, especificamente para el sector agricola. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma, y esta proximo a publicarse como norma oficial mexicana de eficiencia energetica. En el presente articulo se mencionan los resultados del analisis de los sistemas de bombeo en operacion, los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicandose ademas el impacto ambiental que tendra la implantacion de la misma.

  7. Analysis of a 10 megawatt space-based solar-pumped neodymium laser system

    Science.gov (United States)

    Kurweg, U. H.

    1984-01-01

    A ten megawatt solar-pumped continuous liquid laser system for space applications is examined. It is found that a single inflatable mirror of 434 m diameter used in conjunction with a conical secondary concentrator is sufficient to side pump a liquid neodymium lasant in an annular tube of 6 m length and 1 m outer and 0.8 m inner diameter. About one fourth of intercepted radiation converging on the laser tube is absorbed and one fifth of this radiation is effective in populating the upper levels. The liquid lasant is flowed through the annular laser cavity at 1.9 m/s and is cooled via a heat exchanger and a large radiator surface comparable in size to the concentrating mirror. The power density of incident light within the lasant of approximately 68 watt/cu cm required for cw operation is exceeded in the present annular configuration. Total system weight corresponds to 20,500 kg and is thus capable of being transported to near Earth orbit by a single shuttle flight.

  8. Flow characteristics of the raw sewage for the design of sewage-source heat pump systems.

    Science.gov (United States)

    Xu, Ying; Wu, Yuebin; Sun, Qiang

    2014-01-01

    The flow characteristics of raw sewage directly affect the technical and economic performance of sewage-source heat pump systems. The purpose of this research is to characterize the flow characteristics of sewage by experimental means. A sophisticated and flexible experimental apparatus was designed and constructed. Then the flow characteristics of the raw sewage were studied through laboratorial testing and theoretical analyses. Results indicated that raw sewage could be characterized as a power-law fluid with the rheological exponent n being 0.891 and the rheological coefficient k being 0.00175. In addition, the frictional loss factor formula in laminar flow for raw sewage was deduced by theoretical analysis of the power-law fluid. Furthermore, an explicit empirical formula for the frictional loss factor in turbulent flow was obtained through curve fitting of the experimental data. Finally, the equivalent viscosity of the raw sewage is defined in order to calculate the Reynolds number in turbulent flow regions; it was found that sewage had two to three times the viscosity of water at the same temperature. These results contributed to appropriate parameters of fluid properties when designing and operating sewage-source heat pump systems.

  9. System simulation for an untreated sewage source heat pump (USSHP) in winter

    Science.gov (United States)

    Qin, Na; Hao, Peng Z.

    2017-01-01

    The paper discusses the system characteristics of an untreated sewage source heat pump in winter. In this system, the sewage enters into the evaporator directly. The variable parameters to control the system contain the sewage temperature at evaporator inlet and the water temperature at condenser inlet. It is found that most parameters, except the condensation heat transfer coefficient, change in the form of sine wave the same as the sewage temperature at inlet. The heating load and consumed power are 12.9kW and 3.45kW when the sewage temperature at inlet is 13°C. COP is about 3.75 in the range of the sewage temperature at inlet of 12-13°C.

  10. Optimization of an artificial-recharge-pumping system for water supply in the Maghaway Valley, Cebu, Philippines

    Science.gov (United States)

    Kawo, Nafyad Serre; Zhou, Yangxiao; Magalso, Ronnell; Salvacion, Lasaro

    2017-11-01

    A coupled simulation-optimization approach to optimize an artificial-recharge-pumping system for the water supply in the Maghaway Valley, Cebu, Philippines, is presented. The objective is to maximize the total pumping rate through a system of artificial recharge and pumping while meeting constraints such as groundwater-level drawdown and bounds on pumping rates at each well. The simulation models were coupled with groundwater management optimization to maximize production rates. Under steady-state natural conditions, the significant inflow to the aquifer comes from river leakage, whereas the natural discharge is mainly the subsurface outflow to the downstream area. Results from the steady artificial-recharge-pumping simulation model show that artificial recharge is about 20,587 m3/day and accounts for 77% of total inflow. Under transient artificial-recharge-pumping conditions, artificial recharge varies between 14,000 and 20,000 m3/day depending on the wet and dry seasons, respectively. The steady-state optimisation results show that the total optimal abstraction rate is 37,545 m3/day and artificial recharge is increased to 29,313 m3/day. The transient optimization results show that the average total optimal pumping rate is 36,969 m3/day for the current weir height. The transient optimization results for an increase in weir height by 1 and 2 m show that the average total optimal pumping rates are increased to 38,768 and 40,463 m3/day, respectively. It is concluded that the increase in the height of the weir can significantly increase the artificial recharge rate and production rate in Maghaway Valley.

  11. Water reuse and cost-benefit of pumping at different spatial levels in a rice irrigation system in UPRIIS, Philippines

    Science.gov (United States)

    Hafeez, M. M.; Bouman, B. A. M.; Van de Giesen, N.; Mushtaq, S.; Vlek, P.; Khan, S.

    As agricultural water resources in Asia become increasingly scarce, the irrigation efficiency of rice must be improved. However, in this region there is very limited information available about water use efficiency across spatial levels in irrigation systems. This study quantifies the volume of water reuse and its related cost-benefits at five different spatial levels, ranging from 1500 ha to 18,000 ha, under gravity-fed irrigation system in Upper Pumpanga River Integrated Irrigation System (UPRIIS), Philippines. The major sources of water reuse are considered, namely groundwater pumping, pumping from creeks, combined use and irrigation supplies from check dams. The volume of water available from all four sources of water reuse was quantified through extensive measurements. Production functions were developed to quantify water-yield relationships and to measure the economic value of water reuse. This study was conducted during the dry season of 2001, which existed from 19 November 2000 until 18 May 2001. The water reuse by pumping and check dams was 7% and 22% of the applied surface water at District 1 level. The reuse of surface water through check dams increased linearly with 4.6 Mm 3 per added 1000 ha. Similarly, the total amount of reused water from pumping is equivalent to 30% of the water lost through rice evapotranspiration during the dry season 2001. The results showed that water reuse plays a dominant role in growing a rice crop during the dry season. The result showed no difference in pumping costs between the creek (US0.011/m 3) and shallow pumps (US0.012/m 3). The marginal value of productivity (MVP) of water reuse from creek (US0.044/m 3) was slightly higher than the water reuse through the pumping ground water (US0.039/m 3). Results also indicated that the total volume pumped per ha (m 3/ha) was ranging from 0.39 to 6.93 m 3/ha during the dry season. The results clearly indicate that the quantification of amount of water reuse is very crucial for

  12. Numerical estimation of heat distribution from the implantable battery system of an undulation pump LVAD.

    Science.gov (United States)

    Okamoto, Eiji; Makino, Tsutomu; Nakamura, Masatoshi; Tanaka, Shuji; Chinzei, Tsuneo; Abe, Yusuke; Isoyama, Takashi; Saito, Itsuro; Mochizuki, Shu-ichi; Imachi, Kou; Inoue, Yusuke; Mitamura, Yoshinori

    2006-01-01

    We have been developing an implantable battery system using three series-connected lithium ion batteries having an energy capacity of 1,800 mAh to drive an undulation pump left ventricular assist device. However, the lithium ion battery undergoes an exothermic reaction during the discharge phase, and the temperature rise of the lithium ion battery is a critical issue for implantation usage. Heat generation in the lithium ion battery depends on the intensity of the discharge current, and we obtained a relationship between the heat flow from the lithium ion battery q(c)(I) and the intensity of the discharge current I as q(c)(I) = 0.63 x I (W) in in vitro experiments. The temperature distribution of the implantable battery system was estimated by means of three-dimentional finite-element method (FEM) heat transfer analysis using the heat flow function q(c)(I), and we also measured the temperature rise of the implantable battery system in in vitro experiments to conduct verification of the estimation. The maximum temperatures of the lithium ion battery and the implantable battery case were measured as 52.2 degrees C and 41.1 degrees C, respectively. The estimated result of temperature distribution of the implantable battery system agreed well with the measured results using thermography. In conclusion, FEM heat transfer analysis is promising as a tool to estimate the temperature of the implantable lithium ion battery system under any pump current without the need for animal experiments, and it is a convenient tool for optimization of heat transfer characteristics of the implantable battery system.

  13. Penis Pump

    Science.gov (United States)

    ... appointment might be less involved. Choosing a penis pump Some penis pumps are available without a prescription, ... doesn't get caught in the ring. Penis pumps for penis enlargement Many advertisements in magazines and ...

  14. Performance of water source heat pump system using high-density polyethylene tube heat exchanger wound with square copper wire

    Directory of Open Access Journals (Sweden)

    Xin Wen Zhang

    2015-07-01

    Full Text Available Surface water source heat pump system is an energy-efficient heat pump system. Surface water heat exchanger is an important part of heat pump system that can affect the performance of the system. In order to enhance the performance of the system, the overall heat transfer coefficient (U value of the water exchanger using a 32A square copper coiled high-density polyethylene tube was researched. Comparative experiments were conducted between the performance of the coiled high-density polyethylene tube and the 32A smooth high-density polyethylene tube. At the same time, the coefficient of performance of the heat pump was investigated. According to the result, the U value of the coiled tube was 18% higher than that of the smooth tube in natural convection and 19% higher in forced convection. The coefficient of performance of the heat pump with the coiled tube is higher than that with the smooth tube. The economic evaluation of the coiled tube was also investigated.

  15. Comparison of solar heat pump systems to conventional methods for residential heating, cooling, and water heating. Volume 1: Executive Summary

    Science.gov (United States)

    Hughes, P. J.; Morehouse, J. H.

    1980-04-01

    Since the purpose of space conditioning equipment is to provide thermal comfort, models were formulated to force this requirement on all systems. The thermal performance maps (fraction of the load met with free energy versus collector area) presented include the effects of the comfort requirement and of parasitic energy consumption for blower and pump operation. Economic comparisons were made after sizing collectors and storage for the combined solar heat pump systems in a manner which was sensitive to climate as well as to the thermal and economic characteristics of each particular system. This, combined with life cycle cost analysis, allows collector cost goals to be established which, if met, will allow combined solar heat pump systems to compete with conventional alternatives.

  16. High-Temperature Motor Windings for Downhole Pumps Used in Geothermal Energy Production

    Energy Technology Data Exchange (ETDEWEB)

    Hooker, Matthew; Hazelton, Craig; Kano, Kimi

    2010-12-31

    The development of highly reliable downhole equipment is an essential element in enabling the widespread utilization of Enhanced Geothermal Systems (EGS). The downhole equipment used in these systems will be required to operate at high voltages and temperatures on the order of 200 to 250°C (and eventually to 300°C). These conditions exceed the practical operating ranges of currently available thermoplastic wire insulations, and thus limit the operating lifetime of tools such as Electric Submersible Pumps (ESPs). In this work, high-temperature insulations based on composite materials were developed and demonstrated. The products of this work were found to exhibit electrical resistivities and dielectric breakdown strengths that PEEK at temperatures above 250C. In addition, sub-scale motor windings were fabricated and tested to validate the performance of this technology

  17. Energy performance of a ventilation system for a block of apartments with a ground source heat pump as generation system

    Science.gov (United States)

    Lucchi, M.; Lorenzini, M.; Valdiserri, P.

    2017-01-01

    This work presents a numerical simulation of the annual performance of two different systems: a traditional one composed by a gas boiler-chiller pair and one consisting of a ground source heat pump (GSHP) both coupled to two thermal storage tanks. The systems serve a bloc of flats located in northern Italy and are assessed over a typical weather year, covering both the heating and cooling seasons. The air handling unit (AHU) coupled with the GSHP exhibits excellent characteristics in terms of temperature control, and has high performance parameters (EER and COP), which make conduction costs about 30% lower than those estimated for the traditional plant.

  18. The Dynamic Characteristic Analysis of the Water Lubricated Bearing-Rotor System in Seawater Desalination Pump

    Directory of Open Access Journals (Sweden)

    Xiaoyan Ye

    2014-05-01

    Full Text Available In order to study the water lubricated bearing-rotor system in seawater desalination pump, this paper is based on the coupling between the lubricating flow field and the rotor dynamics. The fluid-solid interaction (FSI method, Rigid Body, was adopted to study the journal orbit of the bearing-rotor system under the periodic unbalancing load. The influences of geometric and working parameter to the journal orbit were combined to analyze the stability and reliability of the bearing-rotor system. The result shows that increasing the rotating speed would increase the journal whirling amplitude and the system sensitivity to the external excitation and unbalancing load were promoted; increasing the aspect ratio would reduce the journal whirling amplitude and cause the system to be more unstable; increasing the inlet pressure would reduce the journal whirling amplitude and cause the system to be more unstable; increasing the unbalancing load would reduce the stability margin and the system is easy to be unstable if obstructed; increasing the radial clearance would reduce the journal whirling amplitude and cause the system to be more unstable. The attitude angle has no influence on the journal whirling amplitude but would influence the stability of system and the value of attitude angle should not be large.

  19. Modeling of complex gas distribution systems operating under any vacuum conditions: Simulations of the ITER divertor pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Vasileiadis, N.; Tatsios, G.; Misdanitis, S.; Valougeorgis, D., E-mail: diva@mie.uth.gr

    2016-02-15

    Highlights: • An integrated s/w for modeling complex rarefied gas distribution systems is presented. • Analysis is based on kinetic theory of gases. • Code effectiveness is demonstrated by simulating the ITER divertor pumping system. • The present s/w has the potential to support design work in large vacuum systems. - Abstract: An integrated software tool for modeling and simulation of complex gas distribution systems operating under any vacuum conditions is presented and validated. The algorithm structure includes (a) the input geometrical and operational data of the network, (b) the definition of the fundamental set of network loops and pseudoloops, (c) the formulation and solution of the mass and energy conservation equations, (d) the kinetic data base of the flow rates for channels of any length in the whole range of the Knudsen number, supporting, in an explicit manner, the solution of the conservation equations and (e) the network output data (mainly node pressures and channel flow rates/conductance). The code validity is benchmarked under rough vacuum conditions by comparison with hydrodynamic solutions in the slip regime. Then, its feasibility, effectiveness and potential are demonstrated by simulating the ITER torus vacuum system with the six direct pumps based on the 2012 design of the ITER divertor. Detailed results of the flow patterns and paths in the cassettes, in the gaps between the cassettes and along the divertor ring, as well as of the total throughput for various pumping scenarios and dome pressures are provided. A comparison with previous results available in the literature is included.

  20. Manufacturing of metallic porous structures to be used in capillary pumping systems

    Directory of Open Access Journals (Sweden)

    Eduardo Gonçalves Reimbrecht

    2003-12-01

    Full Text Available Sintered metallic porous structures have an application as capillary structures in two-phase heat transfer loops. In this work the manufacturing procedure of tubular porous structures for capillary pump application is discussed. The application of porous structures on capillary pumping systems requires porosity higher than 40% and pore size diameter lower than 20 µm. Carbonyl nickel powder with particle diameter between 3 and 7 µm and stainless steel AISI316L powder with particle diameter between 1 and 22 µm were used as raw material. Sintering under hydrogen atmosphere was performed both in a resistive furnace and in a plasma reactor. Temperature and time were the modified parameters to obtain suitable porosity and roundness on the samples. The porosity was measured using the Arquimedes Principle (MPIF-42, the roundness was evaluated using a simplified measurement technique of the sample diameter and the pore size distribution was determined by image analysis techniques. Images obtained by Scanning Electronic Microscopy were employed on the image analysis. The sintering parameters selected to manufacture nickel samples were 700 °C and 30 min resulting in a porosity of about 44%. The sintering parameters selected to manufacture stainless steel samples were 1000 °C and 30 min resulting in a porosity of about 40%.

  1. Design and evaluation of osmotic pump-based controlled release system of Ambroxol Hydrochloride.

    Science.gov (United States)

    Cheng, Xiongkai; Sun, Min; Gao, Yan; Cao, Fengliang; Zhai, Guangxi

    2011-08-01

    The purpose of the present study was to design and evaluate an osmotic pump-based drug delivery system for controlling the release of Ambroxol Hydrochloride (Amb). Citric acid, lactose and polyethylene glycol 6000 (PEG 6000) were employed as osmotic agents. Surelease EC containing polyethylene glycol 400 (PEG 400) controlling the membrane porosity was used as semi-permeable membrane. The formulation of tablet core was optimized by orthogonal design and evaluated by weighted mark method. The influences of the amount of PEG 400 and membrane thickness on Amb release were investigated. The optimal osmotic pump tablet (OPT) was evaluated in different release media and at different stirring rates. The major release power confirmed was osmotic pressure. The release of Amb from OPT was verified at a rate of approximately zero-order, and cumulative release percentage at 12?h was 92.6%. The relative bioavailability of Amb OPT in rabbits relative to the commercial sustained capsule was 109.6%. Our results showed that Amb OPT could be a practical preparation with a good prospect.

  2. Numerical Investigation of Miniature Ejector Refrigeration System Embedded with a Capillary Pump Loop

    Directory of Open Access Journals (Sweden)

    Jing-Ming Dong

    2017-07-01

    Full Text Available A miniature steam ejector refrigeration system embedded with a capillary pump loop can result in a compact design which can be used for electronics cooling. In this paper, computational fluid dynamics (CFD is employed to investigate the effects of the area ratio of the ejector constant-area mixing section to the nozzle throat, the length of the constant-area section, and the nozzle exit position (NXP, on the performance of a miniature steam ejector. Results show that the performance of the miniature steam ejector is very sensitive to the area ratio of the constant-area mixing section to the nozzle. For the needs of practical application, the area ratio of the constant-area mixing section to the nozzle should be smaller than 16 when the temperature of the primary flow is 60 °C. The NXP plays an important role in the flow phenomena inside the miniature ejector. The critical back pressure is more sensitive to length of the constant-area mixing section than the entrainment ratio. Results of this investigation provided a good solution to the miniature steam ejector embedded with a capillary pump loop for electronics cooling application.

  3. Geochemical impacts of groundwater heat pump systems in an urban alluvial aquifer with evaporitic bedrock

    Energy Technology Data Exchange (ETDEWEB)

    Garrido Schneider, Eduardo A. [Geological Survey of Spain (IGME), C/ Manuel Lasala no. 44, 9B, 50006 Zaragoza (Spain); García-Gil, Alejandro, E-mail: agargil@unizar.es [Department of Earth Sciences, University of Zaragoza, C/ Pedro Cerbuna 12, 50009 Zaragoza (Spain); GHS, Institute of Environmental Assessment & Water Research (IDAEA), CSIC, Jordi Girona 18–26, 08034 Barcelona (Spain); Vázquez-Suñè, Enric [GHS, Institute of Environmental Assessment & Water Research (IDAEA), CSIC, Jordi Girona 18–26, 08034 Barcelona (Spain); Sánchez-Navarro, José Á. [Department of Earth Sciences, University of Zaragoza, C/ Pedro Cerbuna 12, 50009 Zaragoza (Spain)

    2016-02-15

    In the last decade, there has been an extensive use of shallow geothermal exploitations in urban environments. Although the thermal interference between exploitations has been recently studied, there is a lack of knowledge regarding the geochemical impacts of those systems on the aquifers where they are installed. Groundwater flow line scale and well-doublet scale research work has been conducted at city scale to quantify the geochemical interaction of shallow geothermal exploitations with the environment. A comprehensive analysis was conducted on data obtained from a monitoring network specifically designed to control and develop aquifer policies related to thermal management of the aquifer. The geochemical impacts were evaluated from a thermodynamic point of view by means of saturation index (SI) calculations with respect to the different mineral species considered in the system. The results obtained indicate limited geochemical interaction with the urban environment in most of the situations. However, there are some cases where the interaction of the groundwater heat pump installations with the evaporitic bedrock resulted in the total disablement of the exploitation system operation wells. The application of the tool proposed proved to be pragmatic in the evaluation of geochemical impacts. Injection of water into the aquifer can trigger an important bedrock gypsum and halite dissolution process that is partly responsible for scaling in well casing pipes and collapse of the terrain in the vicinity of injection wells. - Highlights: • We studied geochemical impacts of groundwater heat pump systems. • We have sampled a monitoring network in an energetically exploited urban aquifer. • A limited geochemical interaction has been found in most of the exploitations. • Reinjection into the aquifer produces an important bedrock gypsum dissolution. • Scaling in well casing pipes and collapse of the terrain have been observed.

  4. A numerical study on the oil retention of R410A and PVE oil mixture in multi heat pump system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hak Soo; Kim, Min Soo [Seoul National University, Seoul (Korea, Republic of)

    2016-04-15

    Predicting an amount of discharged oil from a compressor is necessary to charge the compressor with proper amount of oil. The amount of discharged oil can be predicted by calculating the oil retention amount in each component of a heat pump system. This study suggests a method for calculating the oil retention amount in a heat pump system. In addition, flow pattern of refrigerant and oil mixture in horizontal gas line of refrigerant was ascertained by flow visualization. The oil retention amounts in each component of multi heat pump system were calculated with respect to mass flux of refrigerant, Oil circulation ratio (OCR), length of horizontal and vertical lines. Oil retention amounts in horizontal and vertical gas lines of refrigerant were significant. To validate the model for gas lines of refrigerant, comparison between predicted and experimental oil retention amounts was conducted, and mean absolute percentage error was 15.0%.

  5. Optimal control of a fuel cell/wind/PV/grid hybrid system with thermal heat pump load

    CSIR Research Space (South Africa)

    Sichilalu, S

    2016-10-01

    Full Text Available This paper presents an optimal energy management strategy for a grid-tied photovoltaic–wind-fuel cell hybrid power supply system. The hybrid system meets the load demand consisting of an electrical load and a heat pump water heater supplying thermal...

  6. Reducing intravenous therapy errors : Testing the usability of a system for central control of multiple infusion pumps

    NARCIS (Netherlands)

    Cnossen, Fokie; Doesburg, Frank; Nijsten, Maarten

    2015-01-01

    o tackle the problem of “IV spaghetti” and to optimize operation and scheduling of multiple infusion pumps, we propose a new control system that for intermittent medication determines when which medicine has to be started and ended. The system takes medication schedules and dosages, other fluids,

  7. An investigation of the performance of an electronic in-line pump system for diesel engines

    Science.gov (United States)

    Fan, Li-Yun; Zhu, Yuan-Xian; Long, Wu-Qiang; Ma, Xiu-Zhen; Xue, Ying-Ying

    2008-12-01

    WIT Electronic Fuel System Co., Ltd. has developed a new fuel injector, the Electronic In-line Pump (EIP) system, designed to meet China’s diesel engine emission and fuel economy regulations. It can be used on marine diesel engines and commercial vehicle engines through different EIP systems. A numerical model of the EIP system was built in the AMESim environment for the purpose of creating a design tool for engine application and system optimization. The model was used to predict key injection characteristics under different operating conditions, such as injection pressure, injection rate, and injection duration. To validate these predictions, experimental tests were conducted under the conditions that were modeled. The results were quite encouraging and in agreement with model predictions. Additional experiments were conducted to study the injection characteristics of the EIP system. These results show that injection pressure and injection quantity are insensitive to injection timing variations, this is due to the design of the constant velocity cam profile. Finally, injection quantity and pressure vs. pulse width at different cam speeds are presented, an important injection characteristic for EIP system calibration.

  8. Switching from subluminal to superluminal light propagation via a coherent pump field in a four-level atomic system

    Energy Technology Data Exchange (ETDEWEB)

    Kuang Shangqi [College of Physics, Jilin University, Changchun 130023 (China); Key Lab of Coherent Light, Atomic and Molecular Spectroscopy, Educational Ministry of China, Changchun 130021 (China); Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033 (China); Wan Rengang; Kou Jun; Jiang Yun; Gao Jinyue [College of Physics, Jilin University, Changchun 130023 (China); Key Lab of Coherent Light, Atomic and Molecular Spectroscopy, Educational Ministry of China, Changchun 130021 (China)

    2009-12-15

    We theoretically investigate the influence of a coherent pump field on the propagation of a weak light pulse of a probe field in a four-level atomic system. Due to the modulation of the pump field, the light pulse can be manipulated from subluminal to superluminal with negligible distortion. This scheme can be realized in both the ultracold and Doppler-broadened atomic systems. We also demonstrate that the spectral linewidth with an anomalous dispersion is reduced by thermal averaging; therefore, one can obtain a larger negative group refractive index in room-temperature vapor than the largest value achieved in ultracold atomic gas.

  9. Energy optimization in pumping systems; Optimización de energía en sistemas de bombeo

    Directory of Open Access Journals (Sweden)

    Bernardo Roger Sabogal Abril

    2013-06-01

    Full Text Available Within this research a study was performed on energy optimization in pumping systems, highlighting the impact of variable frequency drivers (VFD. This work seeks to propose a model to diagnose pumping systems, contributing towards reduced energy consumption. A search and compilation was performed of theory of pumping systems, AC motors, VFD, and industrial applications. A model is proposed for diagnosis and experimental data was obtained from a test bench. After taking the data, it was proceeded to analyze it on an Excel Tool developed by the author. This tool allowed identifying the system; then, a simulation was performed consisting on assigning a percentage of use to the load curve; thus, showing a saving if the system is used at the highest efficiency point. Lastly, all the procedure was carried out via a system with VFD, which showed less energy consumption. The tool developed in Excel allows, through a set of data, computing load system, pump efficiency, motor efficiency, motor – VFD, and MCC or motor starter.

  10. Parametric pitch instability investigation of Deep Draft Semi-submersible platform in irregular waves

    Directory of Open Access Journals (Sweden)

    Huan Mao

    2016-01-01

    Full Text Available Parametric pitch instability of a Deep Draft Semi-submersible platform (DDS is investigated in irregular waves. Parametric pitch is a form of parametric instability, which occurs when parameters of a system vary with time and the variation satisfies a certain condition. In previous studies, analyzing of parametric instability is mainly limited to regular waves, whereas the realistic sea conditions are irregular waves. Besides, parametric instability also occurs in irregular waves in some experiments. This study predicts parametric pitch of a Deep Draft Semi-submersible platform in irregular waves. Heave motion of DDS is simulated by wave spectrum and response amplitude operator (RAO. Then Hill equation for DDS pitch motion in irregular waves is derived based on linear-wave theory. By using Bubnov-Galerkin approach to solve Hill equation, the corresponding stability chart is obtained. The differences between regular-waves stability chart and irregular-waves stability chart are compared. Then the sensitivity of wave parameters on DDS parametric pitch in irregular waves is discussed. Based on the discussion, some suggestions for the DDS design are proposed to avoid parametric pitch by choosing appropriate parameters. The results indicate that it's important and necessary to predict DDS parametric pitch in irregular waves during design process.

  11. Hybrid space heating/cooling system with Trombe wall, underground venting, and assisted heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Shirley, J.W.; James, L.C.; Stevens, S.; Autry, A.N.; Nussbaum, M.; MacQueen, S.V.

    1983-06-22

    Our goal was to design and monitor a hybrid solar system/ground loop which automatically assists the standard, thermostatically controlled home heating/cooling system. The input from the homeowner was limited to normal thermostat operations. During the course of the project it was determined that to effectively gather data and control the various component interactions, a micro-computer based control system would also allow the HVAC system to be optimized by simple changes to software. This flexibility in an untested concept helped us to achieve optimum system performance. Control ranged from direct solar heating and direct ground loop cooling modes, to assistance of the heat pump by both solar space and ground loop. Sensors were strategically placed to provide data on response of the Trombe wall (surface, 4 in. deep, 8 in. deep), and the ground loop (inlet, 3/4 length, outlet). Micro-computer hardware and computer programs were developed to make cost effective decisions between the various modes of operation. Although recent advances in micro-computer hardware make similar control systems more readily achievable utilizing standard components, attention to the decision making criteria will always be required.

  12. Artificial neural networks and adaptive neuro-fuzzy assessments for ground-coupled heat pump system

    Energy Technology Data Exchange (ETDEWEB)

    Esen, Hikmet; Esen, Mehmet [Department of Mechanical Education, Faculty of Technical Education, Firat University, 23119 Elazig (Turkey); Inalli, Mustafa [Department of Mechanical Engineering, Faculty of Engineering, Firat University, 23279 Elazig (Turkey); Sengur, Abdulkadir [Department of Electronic and Computer Science, Faculty of Technical Education, Firat University, 23119 Elazig (Turkey)

    2008-07-01

    This article present a comparison of artificial neural network (ANN) and adaptive neuro-fuzzy inference systems (ANFIS) applied for modelling a ground-coupled heat pump system (GCHP). The aim of this study is predicting system performance related to ground and air (condenser inlet and outlet) temperatures by using desired models. Performance forecasting is the precondition for the optimal design and energy-saving operation of air-conditioning systems. So obtained models will help the system designer to realize this precondition. The most suitable algorithm and neuron number in the hidden layer are found as Levenberg-Marquardt (LM) with seven neurons for ANN model whereas the most suitable membership function and number of membership functions are found as Gauss and two, respectively, for ANFIS model. The root-mean squared (RMS) value and the coefficient of variation in percent (cov) value are 0.0047 and 0.1363, respectively. The absolute fraction of variance (R{sup 2}) is 0.9999 which can be considered as very promising. This paper shows the appropriateness of ANFIS for the quantitative modeling of GCHP systems. (author)

  13. WiFi Data Acquisition System Applied to a Photovoltaic Powered Water Pumping Plant

    Directory of Open Access Journals (Sweden)

    Sandro César Silveira JUCÁ

    2015-02-01

    Full Text Available The present paper describes how to design and assemble a low cost online monitoring and WiFi data acquisition system using free software applied to microgeneration based on renewable energy sources. The development of online monitoring systems for microgeneration plants based on renewable energy sources is becoming more important, considering that monitoring and data acquisition systems are applicable in stages of the microgeneration process. The monitoring and data acquisition WiFi system was developed using an embedded WiFi modem (Wifly coupled to a microcontrolled board based on the free tool SanUSB. This monitoring system was applied to a photovoltaic (PV water pumping plant without batteries, so as the control system and the wireless communication with the online server, which is also autonomous and powered by PV panel. The free software for online monitoring and WiFi data acquisition allows the analysis of stored data and charts through mobile devices as notebooks, tablets and smartphones.

  14. Requirements Analysis Study for Master Pump Shutdown System Project Development Specification [SEC 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    BEVINS, R.R.

    2000-09-20

    This study is a requirements document that presents analysis for the functional description for the master pump shutdown system. This document identifies the sources of the requirements and/or how these were derived. Each requirement is validated either by quoting the source or an analysis process involving the required functionality, performance characteristics, operations input or engineering judgment. The requirements in this study apply to the first phase of the W314 Project. This document has been updated during the definitive design portion of the first phase of the W314 Project to capture additional software requirements and is planned to be updated during the second phase of the W314 Project to cover the second phase of the project's scope.

  15. Computational design of mixers and pumps for microfluidic systems, based on electrochemically-active conducting polymers.

    Science.gov (United States)

    Kannappan, Karthik; Bogle, Gib; Travas-Sejdic, Jadranka; Williams, David E

    2011-03-28

    We present a theoretical description of the propagation of composition waves along a strip of electrochemically-active conducting polymer, upon electrochemical stimulation. We develop an efficient solution of the electro-neutral Nernst-Plank equations in 2-D for electromigration and diffusional transport in the solution based on an extension of the methods of Scharfetter and Gummel [D. L. Scharfetter and H. K. Gummel, IEEE Trans. Electron Devices, 1969, ED16, 64-77.] and of Cohen and Cooley [H. Cohen and J. W. Cooley, Biophys. J., 1965, 5, 145-162.], and demonstrate important effects of the geometry of the cell. Under some circumstances, waves reflecting back from the end of the strip are predicted. We then demonstrate theoretically how such waves, associated as they are with expansion of the polymer, could be employed to enhance mixing or induce pumping in microfluidic systems.

  16. Energy performance and economic evaluation of heat pump/organic rankine cycle system with sensible thermal storage

    DEFF Research Database (Denmark)

    Carmo, Carolina; Dumont, Olivier; Nielsen, Mads Pagh

    2016-01-01

    that consists of a ground-source heat pump with possibility of reversing operation as an ORC power cycle combined with solar heating in a single-family building is introduced. The ORC mode enables the use of solar energy in periods of no heat energy demand and reverses the heat pump cycle to supply electrical......-life conditions knowledge, the paper considers two different sensible energy storage (TES) configurations for the reversible heat pump/organic Rankine cycle (HP/ORC) system: a buffer tank for both space heating and domestic hot water and a hot water storage tank used exclusively for domestic hot water......The interaction between electrical and thermal energy demands represent a potential area for balancing supply and demand that could contribute to the integration of intermittent renewables in energy systems. To enable the interaction between thermal and electric energy, an innovative concept...

  17. Energy Performance and Economic Evaluation of Heat Pump/Organic Rankine Cycle System with Sensible Thermal Storage

    DEFF Research Database (Denmark)

    Carmo, C.; Dumont, O.; Nielsen, M. P.

    2016-01-01

    that consists of a ground-source heat pump with possibility of reversing operation as an ORC power cycle combined with solar heating in a single-family building is introduced. The ORC mode enables the use of solar energy in periods of no heat energy demand and reverses the heat pump cycle to supply electrical......-life conditions knowledge, the paper considers two different sensible energy storage (TES) configurations for the reversible heat pump/organic Rankine cycle (HP/ORC) system: a buffer tank for both space heating and domestic hot water and a hot water storage tank used exclusively for domestic hot water......The interaction between electrical and thermal energy demands represent a potential area for balancing supply and demand that could contribute to the integration of intermittent renewables in energy systems. To enable the interaction between thermal and electric energy, an innovative concept...

  18. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  19. Autonomous BDFIG-wind generator with torque and pitch control for maximum efficiency in a water pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Camocardi, P. [LEICI, Universidad Nacional de La Plata, 1 y 47, CC 91 (1900) La Plata (Argentina); CONICET (Argentina); Battaiotto, P. [LEICI, Universidad Nacional de La Plata, 1 y 47, CC 91 (1900) La Plata (Argentina); Mantz, R. [LEICI, Universidad Nacional de La Plata, 1 y 47, CC 91 (1900) La Plata (Argentina); Comision de Investigaciones Cientificas de la Provincia de Buenos Aires (Argentina)

    2010-06-15

    This paper presents and analyzes the operation strategy for an autonomous wind energy conversion system oriented to water pumping. It consists of a wind turbine with a Brushless Doubly-Fed Induction Generator (BDFIG), electrically coupled with a squirrel cage induction machine moving a centrifugal type water pump. Because of no brushes and slip rings, the BDFIG is suitable for autonomous systems, which often work in hard conditions. Additionally, the power flow on the BDFIG principal stator could be driven from a fractional power converter connected on the auxiliary stator winding. This Turbine-BDFIG and Motor-Pump configuration provides a high robustness and reliability, reducing the operational and maintenance costs. The operation strategy proposes, for wind speeds smaller than the rated, to maximize the volume of water pumped based on the optimization of the wind energy capture. To do that, a sliding mode control tracks the optimal turbine torque by means of a torque control. Meanwhile, for wind speeds greater than the rated, a pitch control keeps the water pump within the safe operation area by adjusting the speed and power of the turbine in their rated values. To assess and corroborate the proposed strategy, simulations with different wind profiles are made. (author)

  20. New Navigation Post-Processing Tools for Oceanographic Submersibles

    Science.gov (United States)

    Kinsey, J. C.; Whitcomb, L. L.; Yoerger, D. R.; Howland, J. C.; Ferrini, V. L.; Hegrenas, O.

    2006-12-01

    We report the development of Navproc, a new set of software tools for post-processing oceanographic submersible navigation data that exploits previously reported improvements in navigation sensing and estimation (e.g. Eos Trans. AGU, 84(46), Fall Meet. Suppl., Abstract OS32A- 0225, 2003). The development of these tools is motivated by the need to have post-processing software that allows users to compensate for errors in vehicle navigation, recompute the vehicle position, and then save the results for use with quantitative science data (e.g. bathymetric sonar data) obtained during the mission. Navproc does not provide real-time navigation or display of data nor is it capable of high-resolution, three dimensional (3D) data display. Navproc supports the ASCII data formats employed by the vehicles of the National Deep Submergence Facility (NDSF) operated by the Woods Hole Oceanographic Institution (WHOI). Post-processing of navigation data with Navproc is comprised of three tasks. First, data is converted from the logged ASCII file to a binary Matlab file. When loaded into Matlab, each sensor has a data structure containing the time stamped data sampled at the native update rate of the sensor. An additional structure contains the real-time vehicle navigation data. Second, the data can be displayed using a Graphical User Interface (GUI), allowing users to visually inspect the quality of the data and graphically extract portions of the data. Third, users can compensate for errors in the real-time vehicle navigation. Corrections include: (i) manual filtering and median filtering of long baseline (LBL) ranges; (ii) estimation of the Doppler/gyro alignment using previously reported methodologies; and (iii) sound velocity, tide, and LBL transponder corrections. Using these corrections, the Doppler and LBL positions can be recomputed to provide improved estimates of the vehicle position compared to those computed in real-time. The data can be saved in either binary or ASCII

  1. Optimization of ground source heat pumps systems through the implementation of hybrid systems; Optimizacion de las instalaciones de bomba de calor geotermica mediante la implementacion de sistemas hibridos

    Energy Technology Data Exchange (ETDEWEB)

    Magraner, T.; Quilis, M. S.; Martinez, S.

    2009-07-01

    One of the fundamental aspects to consider in the design of a ground heat pump system is the heat balance in the ground since thermal saturation of the ground produces a decreasing of the performance of the system throughout its useful life. The hybrid geothermal system which combined geothermal heat pump system with other systems for generation or dissipation energy are very suitable for balancing the heat exchanger meters needed for the proper functioning of the system, important aspect to reduce costs and achieve attractive return periods of the initial investment. Energesis Ingenieria has developed and implemented in two office buildings, a design of hybrid systems based on the combination of a geothermal heat pump and air-condensed units (dry coolers) that can ensure energy efficiencies comparable to geothermal pure systems, reducing substantially the investment cost. (Author) 5 refs.

  2. Twin screw subsurface and surface multiphase pumps

    Energy Technology Data Exchange (ETDEWEB)

    Dass, P. [CAN-K GROUP OF COMPANIES, Edmonton, Alberta (Canada)

    2011-07-01

    A new subsurface twin screw multiphase pump has been developed to replace ESP and other artificial lift technologies. This technology has been under development for a few years, has been field tested and is now going for commercial applications. The subsurface twin screw technology consists of a pair of screws that do not touch and can be run with a top drive or submersible motor; and it carries a lot of benefits. This technology is easy to install and its low slippage makes it highly efficient with heavy oil. In addition twin screw multiphase pumps are capable of handling high viscosity fluids and thus their utilization can save water when used in thermal applications. It also induces savings of chemicals because asphaltenes do not break down easily as well as a reduction in SOR. The subsurface twin screw multiphase pump presented herein is an advanced technology which could be used in thermal applications.

  3. Recovery act. Development of design and simulation tool for hybrid geothermal heat pump system

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shaojie [ClimateMaster, Inc., Oklahoma City, OK (United States); Ellis, Dan [ClimateMaster, Inc., Oklahoma City, OK (United States)

    2014-05-29

    The ground source heat pump (GSHP) system is one of the most energy efficient HVAC technologies in the current market. However, the heat imbalance may degrade the ability of the ground loop heat exchanger (GLHX) to absorb or reject heat. The hybrid GSHP system, which combines a geothermal well field with a supplemental boiler or cooling tower, can balance the loads imposed on the ground loop heat exchangers to minimize its size while retaining superior energy efficiency. This paper presents a recent simulation-based study with an intention to compare multiple common control strategies used in hybrid GSHP systems, including fixed setpoint, outside air reset, load reset, and wetbulb reset. A small office in Oklahoma City conditioned by a hybrid GSHP system was simulated with the latest version of eQUEST 3.7[1]. The simulation results reveal that the hybrid GSHP system has the excellent capability to meet the cooling and heating setpoints during the occupied hours, balance thermal loads on the ground loop, as well as improve the thermal comfort of the occupants with the undersized well field.

  4. Conventional and Ultrafast Pump-Probe Time-Resolved Raman Spectroscopy of Strongly Correlated Systems

    Science.gov (United States)

    Yang, Jhih-An

    Raman scattering has become an invaluable tool for the study of strongly-correlated systems because it can directly probe phonons, magnetic excitations, and electronic excitations. The extension of Raman scattering to the time domain by using the pump-probe technique allows us to study the femtosecond dynamics under a non-equilibrium condition. Time-resolved Raman scattering thus is able to disentangle different fundamental interactions that are difficult to distinguish in the energy domain by their different temporal evolution. In this thesis we show the development of time-resolved Raman spectroscopy and its applications to investigate non-equilibrium dynamics in novel materials. The first part of this thesis is devoted to using large-shift Raman spectroscopy to study the electronic structure of Sr2IrO4, a spin-orbit-induced Mott insulator. We found two high-energy excitations of the d-shell multiplet at 690 meV and 680 meV with A1g and B1g symmetry respectively. We show that both pseudospin-flip and non-pseudosin-flip dd electronic transitions are Raman active, but only the latter are observed. The second part is devoted to the study of the time dynamics of electron-hole excitations as well as the G-phonon in graphite after an excitation by an intense laser pulse. We found that the increase of the G-phonon population occurs with a delay of ˜65 fs in contradiction with the two-temperature model. This time-delay is also evidenced by the absence of the so-called self-pumping for G phonons. It decreases with increased pump fluence. We show that these observations imply a new relaxation pathway: Instead of hot carriers transferring energy to G-phonons directly, the energy is first transferred to optical phonons near the zone boundary K-points, which then decay into G-phonons via phonon-phonon scattering. In the third part we study magnetic dynamics in insulating YBa2 Cu3O6+x using time-resolved Raman spectroscopy. We observed ultrafast melting of the magnetic order

  5. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  6. Integration of Variable Speed Pumped Hydro Storage in Automatic Generation Control Systems

    Science.gov (United States)

    Fulgêncio, N.; Moreira, C.; Silva, B.

    2017-04-01

    Pumped storage power (PSP) plants are expected to be an important player in modern electrical power systems when dealing with increasing shares of new renewable energies (NRE) such as solar or wind power. The massive penetration of NRE and consequent replacement of conventional synchronous units will significantly affect the controllability of the system. In order to evaluate the capability of variable speed PSP plants participation in the frequency restoration reserve (FRR) provision, taking into account the expected performance in terms of improved ramp response capability, a comparison with conventional hydro units is presented. In order to address this issue, a three area test network was considered, as well as the corresponding automatic generation control (AGC) systems, being responsible for re-dispatching the generation units to re-establish power interchange between areas as well as the system nominal frequency. The main issue under analysis in this paper is related to the benefits of the fast response of variable speed PSP with respect to its capability of providing fast power balancing in a control area.

  7. Screening Criteria for ILs used in NH3 Based Absorption Heat Pump Systems

    NARCIS (Netherlands)

    Wang, M.; Infante Ferreira, C.A.; Groll, Eckhard

    2016-01-01

    This paper describes a properties-optimization work for the working fluids in NH3 / ionic liquid (ILs) based single-effect absorption heat pumps. The optimum parameters of the IL can be used as criteria in screening task-specified ILs, which play the role of absorbents, in absorption heat pumps.

  8. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; de Wit, Jan B.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and

  9. Evaluation of a top hole full return drilling system applying a concentric dual drill string and an integrated pump

    OpenAIRE

    Jonassen, Inger Lise Gjeraldstveit

    2017-01-01

    Master's thesis in Offshore Technology: Marin and Subsea technology This thesis evaluates the possibility for a full mud return, top hole drilling system, applying a concentric dual drill string and an integrated pump. Top holes are usually drilled without mud return, leaving the cuttings on the sea floor. Sea water with barite and other additives are employed as drilling fluid and is released to the sea when used. By employing a dual drill string and a down hole pump to lift the return to...

  10. Evaluation of a top hole full return drilling system applying a concentric dual drill string and an integrated pump

    OpenAIRE

    Jonassen, Inger Lise Gjeraldstveit

    2017-01-01

    This thesis evaluates the possibility for a full mud return, top hole drilling system, applying a concentric dual drill string and an integrated pump. Top holes are usually drilled without mud return, leaving the cuttings on the sea floor. Sea water with barite and other additives are employed as drilling fluid and is released to the sea when used. By employing a dual drill string and a down hole pump to lift the return to top side facilities, full return is enabled. This facilitates the use ...

  11. Mini-Osmotic Pump Infusion Model to Investigate the Systemic Effects of Chronic Continuous Exposure to Staphylococcal Superantigen in Mice.

    Science.gov (United States)

    Krogman, Ashton L; Chowdhary, Vaidehi; Rajagopalan, Govindarajan

    2016-01-01

    Staphylococcus aureus can exist as a colonizer or can cause a spectrum of diseases. S. aureus elaborates several exotoxins and the superantigens are one among them. Staphylococcal superantigens (SSAg) cause robust activation of the immune system and acute exposure to significant amounts of SSAg can be potentially lethal. However, chronic exposure to SSAg is also possible. Administering SSAg using mini-osmotic pumps may mimic chronic recurrent exposure to SSAg. This is a relatively simple and safe way to administer purified SSAg or any other toxin/agent. In this chapter, we describe the mini-osmotic pump-mediated delivery of SSAg.

  12. BOTDA sensing system employing a tunable low-cost Brillouin fiber ring laser pump-probe source

    Science.gov (United States)

    Iuliano, M.; Marini, D.; Bastianini, F.; Bolognini, G.

    2017-04-01

    In this paper we show a Brillouin optical time-domain analysis (BOTDA) sensing system experiment employing a tunable narrow-linewidth dual pump-probe source based on modified Brillouin ring laser technology. The developed cost-effective source generates a pump-locked and tunable probe light, with wavelength shift and a large tuning range ( 200 MHz), narrow linewidth (distributed sensing over 10 km single mode optical fiber, and attaining strain and temperature resolutions of 10μɛ and 0.5 °C respectively, indicating the pump-probe source as an efficient and cost-effective solution for BOTDA avoiding high-frequency signal generators or complex locking techniques.

  13. Study and Optimization of Design Parameters in Water Loop Heat Pump Systems for Office Buildings in the Iberian Peninsula

    Directory of Open Access Journals (Sweden)

    Francisco Javier Fernández

    2017-11-01

    Full Text Available Water loop heat pump (WLHP air conditioning systems use heat pumps connected to a common water circuit to fulfill the energy demands of different thermal zones in a building. In this study, the energy consumption was analyzed for the air conditioning of an office building in the typical climate of four important cities of the Iberian Peninsula. The energy consumption of one water loop heat pump system was compared with a conventional water system. Two design parameters, the range in the control temperatures and the water loop thermal storage size, were tested. Energy redistribution is an important advantage of the WLHP system, but significant savings came from high efficiency parameters in the heat pumps and minor air flow rates in the cooling tower. The low thermal level in the water loop makes this technology appropriate to combine with renewable sources. Using natural gas as the thermal energy source, a mean decrease in CO2 emissions of 8.1% was reached. Simulations showed that the installation of big thermal storage tanks generated small energy savings. Besides, the total annual consumption in buildings with high internal loads can be reduced by keeping the water loop as cool as possible.

  14. Developing and Analysing sub-10 µm Fluidic Systems with Integrated Electrodes for Pumping and Sensing in Nanotechnology Applications

    NARCIS (Netherlands)

    Heuck, F.C.A.

    2010-01-01

    In this thesis, sub-10 µm fluidic systems with integrated electrodes for pumping and sensing in nanotechnology applications were developed and analyzed. This work contributes to the development of the scanning ion pipette (SIP), a tool to investigate surface changes on the nanometer scale induced by

  15. Rheological behavior in Xinglongzhuang coal washery sludge pump system of CFB boiler

    Energy Technology Data Exchange (ETDEWEB)

    Tang, X.; Yang, J.; Jiang, X.; Chi, Y.; Yan, J. [Zhejiang University, Hangzhou (China)

    2007-06-15

    The rheological behaviour of slime was researched and the application reliability of a pump was tested by carrying out a feasibility test and simulating a project test with a KK139 pump made in Germany. The moisture of the slime changed from 27.5% to 30.2% and the frequency of the pump changed from 32.42 Hz to 64.49 Hz. The rheological behaviour of the slime was calculated by a series of hydromechanical formulae. Experimental results show that, in this moisture range, yield shearing stress, shearing stress, apparent viscosity and floating resistance were reduced following increase of moisture. Slime of 27.5% is the lowest moisture level which can be pumped. Slime of 28% is the most economically suitable to pump. Its rheological behaviour has complete transformation from yielding-pseudoplastic to Bingham fluid. 3 refs., 3 figs., 1 tab.

  16. Oxidative regulation of the Na(+)-K(+) pump in the cardiovascular system.

    Science.gov (United States)

    Figtree, Gemma A; Keyvan Karimi, Galougahi; Liu, Chia-Chi; Rasmussen, Helge H

    2012-12-15

    The Na(+)-K(+) pump is an essential heterodimeric membrane protein, which maintains electrochemical gradients for Na(+) and K(+) across cell membranes in all tissues. We have identified glutathionylation, a reversible posttranslational redox modification, of the Na(+)-K(+) pump's β1 subunit as a regulatory mechanism of pump activity. Oxidative inhibition of the Na(+)-K(+) pump by angiotensin II- and β1-adrenergic receptor-coupled signaling via NADPH oxidase activation demonstrates the relevance of this regulatory mechanism in cardiovascular physiology and pathophysiology. This has implications for dysregulation of intracellular Na(+) and Ca(2+) as well as increased oxidative stress in heart failure, myocardial ischemia-reperfusion, and regulation of vascular tone under conditions of elevated oxidative stress. Treatment strategies that are able to reverse this oxidative inhibition of the Na(+)-K(+) pump have the potential for cardiovascular-protective effects. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Analysis of the impact of heat pump technology on the Irish energy system to the year 2000. Energy case study series: No. 2

    Energy Technology Data Exchange (ETDEWEB)

    Brady, J.

    1977-09-15

    An analysis of the impact of existing and new heat pump technology on the Irish energy system to the year 2000 was undertaken. The methodology used involved the measurement of the potential impact against a base Reference Energy System for various heat pump strategies. A short analysis of the implementation rates and their effect on technology impact was also carried out.

  18. Modeling a ground-coupled heat pump system by a support vector machine

    Energy Technology Data Exchange (ETDEWEB)

    Esen, Hikmet; Esen, Mehmet [Department of Mechanical Education, Faculty of Technical Education, Firat University, 23119 Elazig (Turkey); Inalli, Mustafa [Department of Mechanical Engineering, Faculty of Engineering, Firat University, 23279 Elazig (Turkey); Sengur, Abdulkadir [Department of Electronic and Computer Science, Faculty of Technical Education, Firat University, 23119 Elazig (Turkey)

    2008-08-15

    This paper reports on a modeling study of ground coupled heat pump (GCHP) system performance (COP) by using a support vector machine (SVM) method. A GCHP system is a multi-variable system that is hard to model by conventional methods. As regards the SVM, it has a superior capability for generalization, and this capability is independent of the dimensionality of the input data. In this study, a SVM based method was intended to adopt GCHP system for efficient modeling. The Lin-kernel SVM method was quite efficient in modeling purposes and did not require a pre-knowledge about the system. The performance of the proposed methodology was evaluated by using several statistical validation parameters. It is found that the root-mean squared (RMS) value is 0.002722, the coefficient of multiple determinations (R{sup 2}) value is 0.999999, coefficient of variation (cov) value is 0.077295, and mean error function (MEF) value is 0.507437 for the proposed Lin-kernel SVM method. The optimum parameters of the SVM method were determined by using a greedy search algorithm. This search algorithm was effective for obtaining the optimum parameters. The simulation results show that the SVM is a good method for prediction of the COP of the GCHP system. The computation of SVM model is faster compared with other machine learning techniques (artificial neural networks (ANN) and adaptive neuro-fuzzy inference system (ANFIS)); because there are fewer free parameters and only support vectors (only a fraction of all data) are used in the generalization process. (author)

  19. Monitoring of Building Heating and Cooling Systems Based on Geothermal Heat Pump in Galicia (Spain)

    Science.gov (United States)

    Iglesias, M.; Rodriguez, J.; Franco, D.

    2012-10-01

    In November 2009 was signed an agreement between Galicia's Government and EnergyLab to develop a project related with the geothermal heatpumps (hereafter, GSHP) technology. That project consisted in replacing the existing thermal equipment generators (diesel boilers and air-water heat pumps) by GSHP systems in representative public buildings: two nursery schools, a university library, a health centre and a residential building. This new systems will reach the demands of existing heating, cooling and domestic hot water (hereafter, DHW). These buildings can serve as examples of energy and economic savings that can offer this technology. We will show detailed analysis of the GSHP facilities monitored, since the starting-up of them. Which includes: COP's, EER's, energy consumption, operating costs, operation hours of the system, economic and emissions comparative, geothermal exchange evolution graphs, environmental conditions evolution graphs (temperature and demands), etc. The results presented show an example of the important benefits of the GSHP technology and the significant savings that can offer its implementation for heating, cooling and DHW production. Note to the reader: The article number has been corrected on web pages on November 22, 2013.

  20. [Design of the temperature control system for the thermostatic medical infusion pump].

    Science.gov (United States)

    Han, Xuefei; Yan, Rongguo; Ding, Jie; Ge, Bin; Li, Xiaoxia

    2014-12-01

    In surgery operations, wound should be cleaned with warm sterilized saline solution. In order to reach rapidly warming the washing solution from the room temperature during the surgery, we designed a thermostatic medical infusion pump. The present paper mainly presents researches on the two temperature control methods in the standby mode and in the flushing mode of the system. In the standby mode, the traditional proportional-integral-derivative (PID) control algorithm was adopted. In the flushing mode, dynamic characteristics of the system was changed in real time, which made the thermostatic control process more complex, and the fitted control function combined with the PID control algorithm was adopted in this mode. The temperature control parameters were adjusted in real time according to the initial temperature and the flow rate of the washing solution to obtain a constant temperature of the washing solution, no matter how the initial temperature and the flow rate are changed. The experiment results showed that this kind of control system performed well with a high accuracy.

  1. Monitoring of Building Heating and Cooling Systems Based on Geothermal Heat Pump in Galicia (Spain

    Directory of Open Access Journals (Sweden)

    Franco D.

    2012-10-01

    Full Text Available In November 2009 was signed an agreement between Galicia’s Government and EnergyLab to develop a project related with the geothermal heatpumps (hereafter, GSHP technology. That project consisted in replacing the existing thermal equipment generators (diesel boilers and air-water heat pumps by GSHP systems in representative public buildings: two nursery schools, a university library, a health centre and a residential building. This new systems will reach the demands of existing heating, cooling and domestic hot water (hereafter, DHW. These buildings can serve as examples of energy and economic savings that can offer this technology. We will show detailed analysis of the GSHP facilities monitored, since the starting-up of them. Which includes: COP’s, EER’s, energy consumption, operating costs, operation hours of the system, economic and emissions comparative, geothermal exchange evolution graphs, environmental conditions evolution graphs (temperature and demands, etc. The results presented show an example of the important benefits of the GSHP technology and the significant savings that can offer its implementation for heating, cooling and DHW production.

  2. Geochemical impacts of groundwater heat pump systems in an urban alluvial aquifer with evaporitic bedrock.

    Science.gov (United States)

    Garrido Schneider, Eduardo A; García-Gil, Alejandro; Vázquez-Suñè, Enric; Sánchez-Navarro, José Á

    2016-02-15

    In the last decade, there has been an extensive use of shallow geothermal exploitations in urban environments. Although the thermal interference between exploitations has been recently studied, there is a lack of knowledge regarding the geochemical impacts of those systems on the aquifers where they are installed. Groundwater flow line scale and well-doublet scale research work has been conducted at city scale to quantify the geochemical interaction of shallow geothermal exploitations with the environment. A comprehensive analysis was conducted on data obtained from a monitoring network specifically designed to control and develop aquifer policies related to thermal management of the aquifer. The geochemical impacts were evaluated from a thermodynamic point of view by means of saturation index (SI) calculations with respect to the different mineral species considered in the system. The results obtained indicate limited geochemical interaction with the urban environment in most of the situations. However, there are some cases where the interaction of the groundwater heat pump installations with the evaporitic bedrock resulted in the total disablement of the exploitation system operation wells. The application of the tool proposed proved to be pragmatic in the evaluation of geochemical impacts. Injection of water into the aquifer can trigger an important bedrock gypsum and halite dissolution process that is partly responsible for scaling in well casing pipes and collapse of the terrain in the vicinity of injection wells. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Field measurements to demonstrate new technology for heat pump systems; Faeltmaetningar foer att demonstrera ny teknik foer vaermepumpsystem

    Energy Technology Data Exchange (ETDEWEB)

    Tiljander, Pia; Haglund Stignor, Caroline; Lidbom, Peter; Viktorsson, Magnus; Lindahl, Markus; Axell, Monica

    2010-09-15

    Within the frames of this project there are ongoing measurements of five different heat pump facilities used for heating houses and tap water in one-family houses. The measurements started in the first part of 2010 and are supposed to go on for one year. The final result together with analysis and discussions will be presented in a report that will be published in summer 2011. The purpose of the measurements is to present the potential for heat pump technology in order to raise the acceptance of the technology and through raised acceptance increase the implementation of the technology in new markets. The project also has its purpose in usage of the results and conclusions as basic data and guidelines for constructors and assembling fitters. The project is not intended to grade individual heat pumps from various suppliers in regard to efficiency. A field study does not adapt well for comparison between different heat pumps since there are too many variables (outdoor climate, usage pattern, construction of the building, installation solution, kind of heat pump system) that affect the performance of the heating system. Results from field studies should therefore never be used for comparison. This kind of work should be carried out in a laboratory where variables that affect the result can be controlled. The project started with a mapping of the Swedish heat pump market in order to obtain a base when choosing the different heat pump facilities that should be included in the field study. The selection was made together with the heat pump manufacturers with focus on selecting the best possible technology and to include different technologies. Another important criterion for the selection was to find households that agreed to participate in the study. Included in the study are two buildings with geothermal heating, one with geothermal heating combined with solar panels, one brine/water heat pump connected to a ground storage combined with solar panels and one building

  4. Use of sediment CO2 by submersed rooted plants.

    Science.gov (United States)

    Winkel, Anders; Borum, Jens

    2009-05-01

    Submersed plants have different strategies to overcome inorganic carbon limitation. It is generally assumed that only small rosette species (isoetids) are able to utilize the high sediment CO(2) availability. The present study examined to what extent five species of submersed freshwater plants with different morphology and growth characteristics (Lobelia dortmanna, Lilaeopsis macloviana, Ludwigia repens, Vallisneria americana and Hydrocotyle verticillata) are able to support photosynthesis supplied by uptake of CO(2) from the sediment. Gross photosynthesis was measured in two-compartment split chambers with low inorganic carbon availability in leaf compartments and variable CO(2) availability (0 to >8 mmol L(-1)) in root compartments. Photosynthetic rates based on root-supplied CO(2) were compared with maximum rates obtained at saturating leaf CO(2) availability, and (14)C experiments were conducted for two species to localize bottlenecks for utilization of sediment CO(2). All species except Hydrocotyle were able to use sediment CO(2), however, with variable efficiency, and with the isoetid, Lobelia, as clearly the most effective and the elodeid, Ludwigia, as the least efficient. At a water column CO(2) concentration in equilibrium with air, Lobelia, Lilaeopsis and Vallisneria covered >75% of their CO(2) requirements by sediment uptake, and sediment CO(2) contributed substantially to photosynthesis at water CO(2) concentrations up to 1000 micromol L(-1). For all species except Ludwigia, the shoot to root ratio on an areal basis was the single factor best explaining variability in the importance of sediment CO(2). For Ludwigia, diffusion barriers limited uptake or transport from roots to stems and transport from stems to leaves. Submersed plants other than isoetids can utilize sediment CO(2), and small and medium sized elodeids with high root to shoot area in particular may benefit substantially from uptake of sediment CO(2) in low alkaline lakes.

  5. Cavitation wear of pump impellers

    Directory of Open Access Journals (Sweden)

    Mirosław Szala

    2016-12-01

    Full Text Available Cavitation is a common phenomenon in pump systems, negatively influencing their operating parameters and components such as impellers and, thus, causing considerable financial losses. This paper explains the problem of cavitation and cavitation erosion. The causes of cavitation in pump systems are analyzed. A selection of centrifugal pump impellers damaged by cavitation erosion are presented and examined. The authors also discuss ways of preventing cavitation and cavitation erosion in pump systems. Finally, relevant conclusions are drawn.

  6. Sodium dopants in helium clusters: Structure, equilibrium and submersion kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, F. [Laboratoire Interdisciplinaire de Physique, Rue de La Piscine, Campus Saint Martin d’Hères, 38000 Grenoble (France)

    2015-12-31

    Alkali impurities bind to helium nanodroplets very differently depending on their size and charge state, large neutral or charged dopants being wetted by the droplet whereas small neutral impurities prefer to reside aside. Using various computational modeling tools such as quantum Monte Carlo and path-integral molecular dynamics simulations, we have revisited some aspects of the physical chemistry of helium droplets interacting with sodium impurities, including the onset of snowball formation in presence of many-body polarization forces, the transition from non-wetted to wetted behavior in larger sodium clusters, and the kinetics of submersion of small dopants after sudden ionization.

  7. Pressure Pump Power Control in the Primary Circuit of the Heat Exchange System

    Directory of Open Access Journals (Sweden)

    Shilin Aleksandr

    2017-01-01

    Full Text Available In this paper we consider the problem of speed in hot water systems where highly efficient plate heat exchanger is used. Especially marked the problem which is connected with long transition drive of constant speed exceeding the time of the heat exchanger accumulative tank emptying more than twice. As a regulating element in the heat exchange system there was proposed to use asynchronous electric drive of pressure pump in the primary circuit of the heat exchanger. For correct use of such electric drive we solved the problem of control object mathematical model synthesis, which has non-linear properties, in particular, the transfer coefficient of the circuit can vary in more than 6 times. At the same time there was revealed the dependence of the transfer coefficient on the motor speed, which must be considered in the controller synthesis. In conclusion we suggested the solutions of regulators synthesis tasks with customizable settings for speed and switchable structure between relay λ and PI regulators.

  8. Simulating on water storage and pump capacity of "Kencing" river polder system in Kudus regency, Central Java, Indonesia

    Science.gov (United States)

    Wahyudi, Slamet Imam; Adi, Henny Pratiwi; Santoso, Esti; Heikoop, Rick

    2017-03-01

    Settlement in the Jati District, Kudus Regency, Central Java Province, Indonesia, is growing rapidly. Previous paddy fields area turns into new residential, industrial and office buildings. The rain water collected in small Kencing river that flows into big Wulan River. But the current condition, during high rain intensity Wulan river water elevation higher than the Kencing river, so that water can not flow gravity and the area inundated. To reduce the flooding, required polder drainage system by providing a long channel as water storage and pumping water into Wulan river. How to get optimal value of water storage volume, drainage system channels and the pump capacity? The result used to be efficient in the operation and maintenance of the polder system. The purpose of this study is to develop some scenarios water storage volume, water gate operation and to get the optimal value of operational pumps removing water from the Kencing River to Wulan River. Research Method is conducted by some steps. The first step, it is done field orientation in detail, then collecting secondary data including maps and rainfall data. The map is processed into Watershed or catchment area, while the rainfall data is processed into runoff discharge. Furthermore, the team collects primary data by measuring topography to determine the surface and volume of water storage. The analysis conducted to determine of flood discharge, water channel hydraulics, water storage volume and pump capacity corresponding. Based on the simulating of long water storage volume and pump capacity with some scenario trying, it can be determined optimum values. The results used to be guideline in to construction proses, operation and maintenance of the drainage polder system.

  9. Integration between electric heat pump and PV system to increase self-consumption of an office application

    Directory of Open Access Journals (Sweden)

    Roselli Carlo

    2017-01-01

    Full Text Available The paper examines a solar electric driven heat pump serving an office building located in southern Italy. To satisfy space heating and cooling demand a heat pump activated by electric energy available from solar photovoltaic plant is here considered. In order to improve the self-consumption of electricity available from photovoltaic system different configurations were considered introducing an electric storage and an electric vehicle. Dynamic simulations to evaluate energy performance of the system varying photovoltaic peak power (4.5–7.5 kW have been carried out. The proposed system achieves a fossil fuel primary energy saving up to about 96% in comparison to the reference conventional system based on a natural gas fired boiler, an electric chiller and the national electric grid. The results show that fossil fuel primary energy saving is higher when there are no storage battery and electric vehicle.

  10. Commercial building unitary heat pump system with solar heating. Final report, May 1, 1976--October 31, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Drucker, E.E.; Ucar, M.; LaGraff, J.E.

    1978-05-01

    A generalized dynamic computer program (SYRSOL) has been developed for the mathematical simulation of the thermal behavior of multi-zone solar heated buildings. The system modeled employs a series of water-to-air heat pumps connected in a closed loop, flat-plate liquid cooled solar collector, a water storage tank, and a cooling tower. Weather data are represented by sinusoids, which provide a convenient and economical alternative to weather tapes. Results indicate that the use of sinusoidal functions for temperature and monthly average values for cloud cover is quite realistic and accurate. Temperature functions for thirteen cities are presented. A preliminary analysis has been done of the feasibility of using solar-energized desiccant dehumidification systems to reduce summer cooling loads. Service hot water production using a water-to-water heat pump from the storage tank is shown to be highly effective and idle solar collectors can be used directly to make service hot water in the summer. A new mathematical heat pump heating model, in which the COP increases linearly with the source water temperature, has been developed and incorporated into SYRSOL. The computer simulation capability has been extended from a heating season to an entire year. The results of some experiments, that have improved the COP of a heat pump, are also reported.

  11. Operational control and diagnostics of the equipment by the parameters of the electric drive power supply by the example of deep well pump units

    Science.gov (United States)

    Shishlyannikov, D. I.; Vasilyeva, M. A.

    2017-02-01

    Currently, the vast majority of Russian oil wells use oil well pumping units (OPU), equipped with a mechanical drive - a balancing pumping unit. The significant lifetime of balancing pumping units used in oil fields of Russia amounts to full or close to full resource generation and to a high accident rate of the mechanical drive rod of OPU. Reduced material costs for operation and maintenance of OPU may be provided by the rejection of the system of preventive maintenance and service during the transition to the actual technical condition. The article analyzes the statistics of the most frequent crash balancing pumping units of OPU and their causes. The prospect of applying the method of instrument control parameters is proved, and the technical condition of the OPU is assessed based on the analysis of the magnitude and the nature of changes in load drive motors, determined by the recording of the instantaneous values of power consumption. The authors consider the construction and operation of the programmable controller ‘AKD-SK’ manufactured by JSC R&D company ‘ROS’ (Perm). Fundamentals of vattmetrogramm analysis of OPU drive motors are stated, and the character of displaying key defects of submersible pumps and balanced beam unit is described.

  12. Modelling of Thermal Behavior of Borehole Heat Exchangers of Geothermal Heat Pump Heating Systems

    Directory of Open Access Journals (Sweden)

    Gornov V.F.

    2016-01-01

    Full Text Available This article reports results of comparing the accuracy of the software package “INSOLAR.GSHP.12”, modeling non-steady thermal behavior of geothermal heat pump heating systems (GHCS and of the similar model “conventional” using finite difference methods for solving spatial non-steady problems of heat conductivity. The software package is based on the method of formulating mathematical models of thermal behavior of ground low-grade heat collection systems developed by INSOLAR group of companies. Equations of mathematical model of spatial non-steady thermal behavior of ground mass of low-grade heat collection system obtained by the developed method have been solved analytically that significantly reduced computing time spent by the software complex “INSOLAR.GSHP.12” for calculations. The method allows to turn aside difficulties associated with information uncertainty of mathematical models of the ground thermal behavior and approximation of external factors affecting the ground. Use of experimentally obtained information about the ground natural thermal behavior in the software package allows to partially take into account the whole complex of factors (such as availability of groundwater, their velocity and thermal behavior, structure and arrangement of ground layers, the Earth’s thermal background, precipitation, phase transformations of moisture in the pore space, and more, significantly influencing the formation of thermal behavior of the ground mass of a low-grade geothermal heat collection system. Numerical experiments presented in the article confirmed the high convergence of the results obtained through the software package “INSOLAR.GSHP.12” with solutions obtained by conventional finite-difference methods.

  13. Intelligent Diagnosis Method for Centrifugal Pump System Using Vibration Signal and Support Vector Machine

    National Research Council Canada - National Science Library

    Xue, Hongtao; Li, Zhongxing; Wang, Huaqing; Chen, Peng

    2014-01-01

    ...), possibility theory, and Dempster-Shafer theory (DST) on the basis of the vibration signals, to diagnose frequent faults in the centrifugal pump at an early stage, such as cavitation, impeller unbalance, and shaft misalignment...

  14. Repair of gear-type pumps for hydraulic systems of construction machines

    OpenAIRE

    Posviatenko, Ye; Kropivniy, V.; Posviatenko, N.; Rousskykh, V.

    2007-01-01

    Investigation into resource-saving technology of repair of gear-type pumps by contact welding -on some wear-resistant composite sintered powders on the top of teeth with further thermal-cycle treatment has been described.

  15. Stirling cycle heat pump for heating and/or cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Meijer, R.J.; Khalili, K.; Meijer, E.; Godett, T.M.

    1991-03-05

    This patent describes a duplex Stirling cycle machine acting as a heat pump. It comprises: a Stirling engine having pistons axially displaceable within parallel cylinders, the engine further having a swashplate rotatable about an axis of, rotation parallel to the cylinders and defining a plane inclined from the axis of rotation. The pistons connected to the swashplate via crossheads whereby axial displacement of the pistons is converted to rotation of the swashplate, and a Stirling cycle heat pump having a compression heat exchanger, an expansion heat exchanger and a regenerator with pistons equal in number to the engine pistons and axially displaceable within cylinders which are oriented co-axially with the engine cylinders. The crossheads further connected to the heat pump pistons whereby the heat pump pistons move simultaneously with the engine pistons over an equal stroke distance.

  16. Compact fibre-laser-pumped Ho:YLF oscillator–amplifier system

    CSIR Research Space (South Africa)

    Koen, W

    2010-04-01

    Full Text Available with the predicted values from a two dimensional rotational symmetric amplifier model that we developed. The model considers upconversion losses and ground-state depletion, as well as the spatial distribution of the pump beam...

  17. Fluid electrodes for submersible robotics based on dielectric elastomer actuators

    Science.gov (United States)

    Christianson, Caleb; Goldberg, Nathaniel; Cai, Shengqiang; Tolley, Michael T.

    2017-04-01

    Recently, dielectric elastomer actuators (DEAs) have gathered interest for soft robotics due to their low cost, light weight, large strain, low power consumption, and high energy density. However, developing reliable, compliant electrodes for DEAs remains an ongoing challenge due to issues with fabrication, uniformity of the conductive layer, and mechanical stiffening of the actuators caused by conductive materials with large Young's moduli. In this work, we present a method for preparing, patterning, and utilizing conductive fluid electrodes. Further, when we submerse the DEAs in a bath containing a conductive fluid connected to ground, the bath serves as a second electrode, obviating the need for depositing a conductive layer to serve as either of the electrodes required of most DEAs. When we apply a positive electrical potential to the conductive fluid in the actuator with respect to ground, the electric field across the dielectric membrane causes charge carriers in the solution to apply an electrostatic force on the membrane, which compresses the membrane and causes the actuator to deform. We have used this process to develop a tethered submersible robot that can swim in a tank of saltwater at a maximum measured speed of 9.2 mm/s. Since saltwater serves as the electrode, we overcome buoyancy issues that may be a challenge for pneumatically actuated soft robots and traditional, rigid robotics. This research opens the door to low-power underwater robots for search and rescue and environmental monitoring applications.

  18. Recent Progress on Submersions: A Survey and New Properties

    Directory of Open Access Journals (Sweden)

    Gabriel Picavet

    2013-01-01

    Full Text Available This paper is a survey about recent progress on submersive morphisms of schemes combined with new results that we prove. They concern the class of quasicompact universally subtrusive morphisms that we introduced about 30 years ago. They are revisited in a recent paper by Rydh, with substantial complements and key results. We use them to show Artin-Tate-like results about the 14th problem of Hilbert, for a base scheme either Noetherian or the spectrum of a valuation domain. We look at faithfully flat morphisms and get “almost” Artin-Tate-like results by considering the Goldman (finite type points of a scheme. Bjorn Poonen recently proved that universally closed morphisms are quasicompact. By introducing incomparable morphisms of schemes, we are able to characterize universally closed surjective morphisms that are either integral or finite. Next we consider pure morphisms of schemes introduced by Mesablishvili. In the quasicompact case, they are universally schematically dominant morphisms. This leads us to a characterization of universally subtrusive morphisms by purity. Some results on the schematically dominant property are given. The paper ends with properties of monomorphisms and topological immersions, a dual notion of submersions.

  19. Water Treatment Technology - Pumps.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on pumps provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pumps in plant and distribution systems, pump…

  20. Improved Design Tools for Surface Water and Standing Column Well Heat Pump Systems (DE-EE0002961)

    Energy Technology Data Exchange (ETDEWEB)

    Spitler, J. D.; Culling, J. R.; Conjeevaram, K.; Ramesh, M.; Selvakumar, M.

    2012-11-30

    Ground-source heat pump (GSHP) systems are perhaps the most widely used “sustainable” heating and cooling systems, with an estimated 1.7 million installed units with total installed heating capacity on the order of 18 GW. They are widely used in residential, commercial, and institutional buildings. Standing column wells (SCW) are one form of ground heat exchanger that, under the right geological conditions, can provide excellent energy efficiency at a relatively low capital cost. Closed-loop surface water heat pump (SWHP) systems utilize surface water heat exchangers (SWHE) to reject or extract heat from nearby surface water bodies. For building near surface water bodies, these systems also offer a high degree of energy efficiency at a low capital cost. However, there have been few design tools available for properly sizing standing column wells or surface water heat exchangers. Nor have tools for analyzing the energy consumption and supporting economics-based design decisions been available. The main contributions of this project lie in providing new tools that support design and energy analysis. These include a design tool for sizing surface water heat exchangers, a design tool for sizing standing column wells, a new model of surface water heat pump systems implemented in EnergyPlus and a new model of standing column wells implemented in EnergyPlus. These tools will better help engineers design these systems and determine the economic and technical feasibility.