WorldWideScience

Sample records for subject transmission lines

  1. Performance Evaluation on Transmission Tower-Line System with Passive Friction Dampers Subjected to Wind Excitations

    Directory of Open Access Journals (Sweden)

    Bo Chen

    2015-01-01

    Full Text Available The vibration control and performance evaluation on a transmission-tower line system by using friction dampers subjected to wind excitations are carried out in this study. The three-dimensional finite element (FE model of a transmission tower is firstly constructed. A two-dimensional lumped mass model of a transmission tower is developed for dynamic analysis. The analytical model of transmission tower-line system is proposed by taking the dynamic interaction between the tower and the transmission lines into consideration. The mechanical model of passive friction damper is presented by involving the effects of damper axial stiffness. The equation of motion of the transmission tower-line system incorporated with the friction dampers disturbed by wind excitations is established. A real transmission tower-line system is taken as an example to examine the feasibility and reliability of the proposed control approach. An extensive parameter study is carried out to find the optimal parameters of friction damper and to assess the effects of slipping force axial stiffness and hysteresis loop on control performance. The work on an example structure indicates that the application of friction dampers with optimal parameters could significantly reduce wind-induced responses of the transmission tower-line system.

  2. Seismic Response of Power Transmission Tower-Line System Subjected to Spatially Varying Ground Motions

    Directory of Open Access Journals (Sweden)

    Li Tian

    2010-01-01

    Full Text Available The behavior of power transmission tower-line system subjected to spatially varying base excitations is studied in this paper. The transmission towers are modeled by beam elements while the transmission lines are modeled by cable elements that account for the nonlinear geometry of the cables. The real multistation data from SMART-1 are used to analyze the system response subjected to spatially varying ground motions. The seismic input waves for vertical and horizontal ground motions are also generated based on the Code for Design of Seismic of Electrical Installations. Both the incoherency of seismic waves and wave travel effects are accounted for. The nonlinear time history analytical method is used in the analysis. The effects of boundary conditions, ground motion spatial variations, the incident angle of the seismic wave, coherency loss, and wave travel on the system are investigated. The results show that the uniform ground motion at all supports of system does not provide the most critical case for the response calculations.

  3. Radio and line transmission 2

    CERN Document Server

    Roddy, Dermot

    2013-01-01

    Radio and Line Transmission, Volume 2 gives a detailed treatment of the subject as well as an introduction to additional advanced subject matter. Organized into 14 chapters, this book begins by explaining the radio wave propagation, signal frequencies, and bandwidth. Subsequent chapters describe the transmission lines and cables; the aerials; tuned and coupled circuits; bipolar transistor amplifiers; field-effect transistors and circuits; thermionic valve amplifiers; LC oscillators; the diode detectors and modulators; and the superheterodyne receiver. Other chapters explore noise and interfere

  4. Series Transmission Line Transformer

    Science.gov (United States)

    Buckles, Robert A.; Booth, Rex; Yen, Boris T.

    2004-06-29

    A series transmission line transformer is set forth which includes two or more of impedance matched sets of at least two transmissions lines such as shielded cables, connected in parallel at one end ans series at the other in a cascading fashion. The cables are wound about a magnetic core. The series transmission line transformer (STLT) which can provide for higher impedance ratios and bandwidths, which is scalable, and which is of simpler design and construction.

  5. ANALYSIS OF THE INSULATION OF AERIAL TRANSMISSION LINES SUBJECT TO VOLTAGE SURGES

    OpenAIRE

    PAULO ALEXANDRE MACHADO

    1975-01-01

    Vários aspectos de um sistema elétrico de potência devem ser avaliados em detalhe antes de sua construção e operação. A escolha dos níveis de isolamento utilizadas é editada pelas condições em regime permanente e de sobre tensões que poderão ocorrer no sistema. Naturalmente, as linhas de transmissão veículos de transporte de energia estão intimamente ligadas a este problema. A sua perfeita operação determina níveis de atendimento apropriados aos consumi...

  6. Kansas Electric Transmission Lines

    Data.gov (United States)

    Kansas Data Access and Support Center — This data set is a digital representation of the EletcircTransmission lines for the State of Kansas as maintained by the Kansas Corporation Commission. Data is...

  7. Electric Power Transmission Lines

    Data.gov (United States)

    Department of Homeland Security — Transmission Lines are the system of structures, wires, insulators and associated hardware that carry electric energy from one point to another in an electric power...

  8. Superconducting metamaterial transmission line

    Science.gov (United States)

    Rouxinol, Francisco; Wang, Haozhi; Plourde, B. L. T.

    2014-03-01

    Left-handed metamaterials are artificial composite structures with unusual properties. Such systems have a wide range of potential applications in photonics. We are developing transmission lines composed of superconducting metamaterials using thin-film lumped circuit elements. Such structures allow for the possibility of generating novel transmission spectra with a high density of modes in some frequency ranges and stop-bands in others. We discuss possible couplings of these lines to superconducting qubits in circuit QED architectures.

  9. Automatic transmission line monitor

    Science.gov (United States)

    Parsons, W. E.; Richards, L. O.

    1971-01-01

    Monitor improves complex network reliability in computer data links and command transmission lines. System evaluates circuit performance against preselected criteria, identifies and stores data indicating out-of-tolerance conditions, conducts closed loop testing, and provides for operation under command of digital computer that determines restoration priorities.

  10. Printed circuit dispersive transmission line

    Science.gov (United States)

    Ikezi, Hiroyuki; Lin-Liu, Yuh-Ren; DeGrassie, John S.

    1991-01-01

    A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other.

  11. VT Digital Line Graph Miscellaneous Transmission Lines

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This datalayer is comprised of Miscellaineous Transmission Lines. Digital line graph (DLG) data are digital representations of cartographic...

  12. Drill string transmission line

    Science.gov (United States)

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David S.; Bradford, Kline; Fox, Joe

    2006-03-28

    A transmission line assembly for transmitting information along a downhole tool comprising a pin end, a box end, and a central bore traveling between the pin end and the box end, is disclosed in one embodiment of the invention as including a protective conduit. A transmission line is routed through the protective conduit. The protective conduit is routed through the central bore and the ends of the protective conduit are routed through channels formed in the pin end and box end of the downhole tool. The protective conduit is elastically forced into a spiral or other non-linear path along the interior surface of the central bore by compressing the protective conduit to a length within the downhole tool shorter than the protective conduit.

  13. Subjective poverty line definitions

    NARCIS (Netherlands)

    J. Flik; B.M.S. van Praag (Bernard)

    1991-01-01

    textabstractIn this paper we will deal with definitions of subjective poverty lines. To measure a poverty threshold value in terms of household income, which separates the poor from the non-poor, we take into account the opinions of all people in society. Three subjective methods will be discussed

  14. Composite Based EHV AC Overhead Transmission Lines

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard

    Overhead lines at transmission level are the backbone of any national power grid today. New overhead line projects however are at the same time subject to ever greater public resistance due to the lines environmental impact. As full undergrounding of transmission lines at extra high voltage (EHV...... and analysed with regard to the possibilities, limitations and risks widespread application of composite materials on EHV AC overhead transmission lines may present. To form the basis for evaluation of the useability of composite materials, dierent overhead line projects aimed at reducing the environmental...

  15. A Quantitative Transmission Line Experiment

    Science.gov (United States)

    Johnston, D. C.; Silbernagel, B. G.

    1969-01-01

    Describes modifications of a commercially available strip-type transmission line, which makes possible reproducible measurements of standing waves on the line. Experimental data yield values for the characteristic impedance, phase velocity and line wavelength of radiation in the transmission line, and the dielectric constant of material in the…

  16. VT Electric Transmission Line Corridors - corridor lines

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The ELTRN layer depicts electric transmission line corridors in Vermont. Various methods have been used to digitize features. The data layer...

  17. A transmission line phase stabilizer

    Science.gov (United States)

    Lutes, G. F.

    1979-01-01

    To meet the phase stability requirements of certain experiments performed with the Deep Space Network, transmission lines carrying reference signals must be stabilized to reduce changes in their electrical length due to mechanical movement or changes in ambient temperature. A transmission line phase stabilizer being developed at JPL to perform this function is described.

  18. Transmission-Line Metamaterials, Bianisotropy, and Transmission-Line Bianisotropy

    OpenAIRE

    Vehmas, Joni

    2015-01-01

    Electromagnetic metamaterials are artificial composite materials which possess exotic and advantageous properties not attainable with natural materials. This thesis covers two notable classes of metamaterials: transmission-line metamaterials and bianisotropic media. While metamaterials are most commonly realized as bulk media consisting of small resonant inclusions, transmission-line structures offer an alternative, low-dispersion and low-loss way for realizing them. Bianisotropic media, on t...

  19. Electrical transmission line diametrical retainer

    Science.gov (United States)

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Briscoe, Michael; Fox, Joe

    2004-12-14

    The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within down hole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to with stand the tension and compression of drill pipe during routine drilling cycles.

  20. Fractional Transmission Line with Losses

    Science.gov (United States)

    Gómez-Aguilar, José Francisco; Dumitru, Baleanu

    2014-11-01

    In this manuscript, the fractional transmission line with losses is presented. The order of the Caputo derivative is considered as 0 Mittag-Leffler functions. The classic cases are recovered when β and γ are equal to 1.

  1. Transmission line model for nanoelectronics

    Directory of Open Access Journals (Sweden)

    Nelin E. A.

    2009-08-01

    Full Text Available Analytical expressions for resonant parametres and characteristics of typical barrier nanoelectronic structures have been received on the basis of the transmission line model. Characteristics illustrating the efficiency of such approach are presented in the article.

  2. Atlas transmission line breakdown analysis

    CERN Document Server

    Nielsen, K E; Ballard, E O; Elizondo, J M; Gribble, R F; McCuistian, B T; Parsons, W M

    1999-01-01

    The Atlas facility will use 24 radially converging, vertically oriented and tapered, oil insulated, triplate transmission lines between the Marx generators and the central load region. Among the requirements of the transmission lines are low inductance and high reliability. The inter-conductor gap is nominally 2 cm and the lines taper from a height of 1.75 m at the Marx end to 0.32 m at the output end. The aluminum conductors, held together by 20 insulating spacers, are assembled and inserted as a unit into radial oil-filled steel tanks. The negative, high-voltage, center conductor is 2.54-cm thick and the outer ground conductors are 1.59-cm thick. All 24 triplate transmission lines connect to a transition section at near 1 m radius that couples the transmission lines to a disk/conical solid- dielectric-insulated power flow channel transmission line terminating at the load. Peak operating voltage on the lines can be as high as 240 kV with an effective stress time of 0.8 mu s. Testing of small sections of the ...

  3. Signal Transmission on Power Lines

    DEFF Research Database (Denmark)

    Dalby, Arne Brejning

    1997-01-01

    coupled transmission line circuits like power line circuits, is based on finding the eigenvalues and eigenvectors for the matrix ZY, where Z and Y are the impedance- and admittance matrices for the coupled lines in W/m and S/m. In this paper a flow-graph representation of the relations beween voltage......- and current-vectors is presented for a general coupled line circuit. This flow-graph can be used to find any transfer function on a multiple coupled lossy transmission line circuit. In some cases, however, it is difficult to find the eigenvalues correctly. A correct analysis can thus not be made......In the analysis of power-line networks over a large frequency span, the time-domain method used in programs like EMTP (Electromagnetic Time domain Program) can not be used. A more rigorous analysis method must be employed. The correct analysis method (assuming TEM-mode propagation) for multiple...

  4. Electrically Isolating Transmission-Line Driver

    Science.gov (United States)

    Marchman, Robert H.

    1992-01-01

    Proposed optoelectronic coupling circuit used to insert signal in transmission line and to isolate transmission line from ground of circuit in which signal originates. Made from commercially available components, reduces susceptibility to interference along transmission path.

  5. Pulse shaping with transmission lines

    Science.gov (United States)

    Wilcox, Russell B.

    1987-01-01

    A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

  6. Coiled transmission line pulse generators

    Science.gov (United States)

    McDonald, Kenneth Fox

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  7. ac transmission line field measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kotter, F.R.; Misakian, M.

    1977-11-01

    The concern in recent years over the environmental effects of electric and magnetic fields from high voltage transmission lines has also focused attention on the accuracy of measurements of these fields. Electric field meters are discussed in terms of theory of operation, parameters affecting performance, meter performance under field and laboratory conditions, and calibration procedures. The performance and calibration of magnetic field meters is described. (LCL)

  8. 18 CFR 2.2 - Transmission lines.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Transmission lines. 2.2... Under the Federal Power Act § 2.2 Transmission lines. In a public statement dated March 7, 1941, the Commission announced its determination that transmission lines which are not primary lines transmitting power...

  9. Transmission line studies for ITER compatible reflectometers

    NARCIS (Netherlands)

    Wagner, D.; Kasparek, W.; Gantenbein, G.; Manso, M. E.; Sanchez, J.; Donne, A. J. H.

    1997-01-01

    Corrugated circular transmission lines are considered as high performance, low loss, broadband lines for reflectometry on ITER. These lines are proposed as a possible solution for the equatorial low-field-side system and as a part (receiver-vacuum vessel) of the transmission lines for the high-field

  10. Superconducting transmission line particle detector

    Science.gov (United States)

    Gray, Kenneth E.

    1989-01-01

    A microvertex particle detector for use in a high energy physic collider including a plurality of parallel superconducting thin film strips separated from a superconducting ground plane by an insulating layer to form a plurality of superconducting waveguides. The microvertex particle detector indicates passage of a charged subatomic particle by measuring a voltage pulse measured across a superconducting waveguide caused by the transition of the superconducting thin film strip from a superconducting to a non-superconducting state in response to the passage of a charged particle. A plurality of superconducting thin film strips in two orthogonal planes plus the slow electromagnetic wave propogating in a superconducting transmission line are used to resolve N.sup.2 ambiguity of charged particle events.

  11. Twisted shield-pair transmission line

    Science.gov (United States)

    Lind, W. N.; Waddy, G. H.

    1977-01-01

    Lightweight cable forms balanced transmission line and replaces costlier coaxial cables for multiplex-signal transmission. Cable is fabricated with carefully-controlled electrical characteristics and functions without tuning networks at frequencies up to 10 MHz.

  12. Coding for Single-Line Transmission

    Science.gov (United States)

    Madison, L. G.

    1983-01-01

    Digital transmission code combines data and clock signals into single waveform. MADCODE needs four standard integrated circuits in generator and converter plus five small discrete components. MADCODE allows simple coding and decoding for transmission of digital signals over single line.

  13. Detonator comprising a nonlinear transmission line

    Science.gov (United States)

    Elizondo-Decanini, Juan M

    2014-12-30

    Detonators are described herein. In a general embodiment, the detonator includes a nonlinear transmission line that has a variable capacitance. Capacitance of the nonlinear transmission line is a function of voltage on the nonlinear transmission line. The nonlinear transmission line receives a voltage pulse from a voltage source and compresses the voltage pulse to generate a trigger signal. Compressing the voltage pulse includes increasing amplitude of the voltage pulse and decreasing length of the voltage pulse in time. An igniter receives the trigger signal and detonates an explosive responsive to receipt of the trigger signal.

  14. RF Transmission Lines on Silicon Substrates

    Science.gov (United States)

    Ponchak, George E.

    1999-01-01

    A review of RF transmission lines on silicon substrates is presented. Through measurements and calculated results, it is shown that attenuation is dominated by conductor loss if silicon substrates with a resistivity greater than 2500 Ohm-cm are used. Si passivation layers affect the transmission line attenuation; however, measured results demonstrate that passivation layers do not necessarily increase attenuation. If standard, low resistivity Si wafers must be used, alternative transmission lines such as thin film microstrip and Co-Planar Waveguide (CPW) on thick polyimide layers must be used. Measured results presented here show that low loss per unit length is achievable with these transmission lines.

  15. Transmission line design for the lunar environment

    Science.gov (United States)

    Gaustad, Krista L.; Gordon, Lloyd B.

    1990-01-01

    How the mass, operating temperature, and efficiency of a transmission line operating on the moon are affected by its operating parameters, the lunar environment, and the choice of materials is examined. The key transmission line parameters which have an effect on mass, operating temperature, and efficiency are voltage, power loss, and waveform. The choice of waveform for transmission will be influenced by the waveform of the source and load, and therefore an analysis of both DC and AC transmission is necessary for a complete understanding of lunar power transmission. The data presented are for the DC case only; however, the discussion of the environmental effects and of material selection is pertinent to both AC and DC transmission. The operating voltage is shown to be a key parameter in transmission line design. The role efficiency plays in transmission line design is also examined. The analyses include above- and below-the-surface operation for both a vacuum-insulated, two-wire, transmission line, and a solid-dielectric-insulated, coaxial, transmission line.

  16. Determination of Transmission Line Impedance Matching Parameters

    African Journals Online (AJOL)

    In this work, transmission line impedance matching parameters were determined in Ugbowo ED0024GI Global System for Mobile Communication (GSM) base station in Benin City, Edo State, Nigeria. The transmission line impedance matching parameter viz voltage standing wave ratio was measured with the aid of the ...

  17. Transmission Lines in CMOS: An Explorative Study

    NARCIS (Netherlands)

    Klumperink, Eric A.M.; Kreienkamp, R.; Ellermeyer, T.; Langmann, U.

    On-chip transmission line modelling and design become increasingly important as frequencies are continuously going up. This paper explores possibilities to implement transmission lines on CMOS ICs via coupled coplanar strips. EM-field simulations with SONNET are used to estimate important

  18. RF transmission lines on silicon substrates

    OpenAIRE

    Ponchak, George E.

    1999-01-01

    A review of RF transmission lines on silicon substrates is presented. Through measurements and calculated results, it is shown that attenuation is dominated by conductor loss if silicon substrates with a resistivity greater than 2500 Q-cm are used. Si passivation layers affect the transmission line attenuation; however, measured results demonstrate that passivation layers do not necessarily increase attenuation. If standard, low resistivity Si wafers must be used, alternative transmission lin...

  19. Single transmission line data acquisition system

    Science.gov (United States)

    Fasching, George E.

    1984-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

  20. VT Electric Transmission Line Corridors - substation points

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The ELTRN layer depicts electric transmission line corridors in Vermont. Various methods have been used to digitize features. The data layer...

  1. Electrical Transmission Line Diametrical Retention Mechanism

    Science.gov (United States)

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Briscoe, Michael; Fox, Joe

    2006-01-03

    The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.

  2. The inverse scattering problem for transmission lines

    Science.gov (United States)

    Kay, I.

    1972-01-01

    A number of exact and approximate methods for solving the inverse scattering problem for transmission lines are reviewed. In particular, the application to transmission lines of Marcenko's version of the Gelfand-Levitan exact method for the quantum mechanical problem is compared with a more direct approach based on a different version of the Gelfand-Levitan method. In addition, some aspects of the lack of uniqueness of solutions are discussed, and some open questions related to the inverse scattering problem are suggested.

  3. Transmission Line Resonator Segmented with Series Capacitors

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Boer, Vincent; Petersen, Esben Thade

    2016-01-01

    Transmission line resonators are often used as coils in high field MRI. Due to distributed nature of such resonators, coils based on them produce inhomogeneous field. This work investigates application of series capacitors to improve field homogeneity along the resonator. The equations for optimal...... values of evenly distributed capacitors are presented. The performances of the segmented resonator and a regular transmission line resonator are compared....

  4. The LHCb VELO analogue transmission line

    Science.gov (United States)

    Bay, A.; Borel, J.; Buytaert, J.; De Laere, S.; Frei, R.; Haefeli, G.; Koppenburg, P.; Locatelli, L.; Schneider, O.; Zehr, F.

    2010-02-01

    The Vertex Locator is one of the most important sub-detectors of the LHCb experiment, which is devoted to B physics. The signals from the silicon strip sensors are multiplexed at 40 MHz and transported by 60 m copper lines to the counting stations placed in a radiation safe area. This paper describes the development of this long transmission line and its performance.

  5. Structural Modules Would Contain Transmission Lines

    Science.gov (United States)

    Leavy, W. A.

    1982-01-01

    New proposal, originally suggested for Spacecraft, is a set of uniformly sized mass-producible modular structural elements that contain electric, fluid, and other transmission lines. Since lines are encapsulated, they are less likely to be damaged. Module shell could be solid metal, sheet metal, honeycomb, fiberglass, plastic, composites, or wood.

  6. Load-resistant coaxial transmission line

    Science.gov (United States)

    Hall, David R.; Fox, Joe

    2006-01-03

    A transmission line for downhole tools that make up all or part of a tool string for drilling and production of oil, gas, and geothermal wells that can withstand the dynamic gravitational forces and other accelerations associated with downhole excavations. The transmission line has a metal tube, or outer conductor, that houses a coaxial wire inner conductor. A non-metallic dielectric material is interposed between the inner and outer conductors. The outer and inner conductors and the dielectric are sufficiently compressed together so that independent motion between them is abated. Compression of the components of the transmission line may be achieved by drawing the transmission through one or more dies in order to draw down the outer conductor onto the dielectric, or by expanding the inner conductor against the dielectric using a mandrel or hydraulic pressure. Non-metallic bead segments may be used in aid of the compression necessary to resist the dynamic forces and accelerations of drilling.

  7. Transmission of Electric Energy Along Long Lines

    Directory of Open Access Journals (Sweden)

    Berzan V.P.

    2009-08-01

    Full Text Available Transmission of electric energy along long lines is examined and characteristics of the change of capacities at the beginning and at the end of a line are submitted: factor of capacity, efficiency of a transmission line, currents depending on length, parameters of a line and parameters of loading. Influence of losses upon the dynamics of instant values of voltages and currents in the opened and short-circuited long lines is investigated and effects of nonlinearity in such chains are revealed at a power supply from a sinusoidal source of voltage. It is shown, that the method of complex amplitudes is not always applicable for the calculation of modes in long lines.

  8. Transmission Line Adapted Analytical Power Charts Solution

    Science.gov (United States)

    Sakala, Japhet D.; Daka, James S. J.; Setlhaolo, Ditiro; Malichi, Alec Pulu

    2017-08-01

    The performance of a transmission line has been assessed over the years using power charts. These are graphical representations, drawn to scale, of the equations that describe the performance of transmission lines. Various quantities that describe the performance, such as sending end voltage, sending end power and compensation to give zero voltage regulation, may be deduced from the power charts. Usually required values are read off and then converted using the appropriate scales and known relationships. In this paper, the authors revisit this area of circle diagrams for transmission line performance. The work presented here formulates the mathematical model that analyses the transmission line performance from the power charts relationships and then uses them to calculate the transmission line performance. In this proposed approach, it is not necessary to draw the power charts for the solution. However the power charts may be drawn for the visual presentation. The method is based on applying derived equations and is simple to use since it does not require rigorous derivations.

  9. Low-noise cryogenic transmission line

    Science.gov (United States)

    Norris, D.

    1987-01-01

    New low-noise cryogenic input transmission lines have been developed for the Deep Space Network (DSN) at 1.668 GHz for cryogenically cooled Field Effect Transistors (FET) and High Electron Mobility Transistor (HEMT) amplifiers. These amplifiers exhibit very low noise temperatures of 5 K to 15 K, making the requirements for a low-noise input transmission line critical. Noise contribution to the total amplifier system from the low-noise line is less than 0.5 K for both the 1.668-GHz and 2.25-GHz FET systems. The 1.668-GHz input line was installed in six FET systems which were implemented in the DSN for the Venus Balloon Experiment. The 2.25-GHz input line has been implemented in three FET systems for the DSN 34-m HEF antennas, and the design is currently being considered for use at higher frequencies.

  10. Application of transmission-line super theory to classical transmission lines with risers

    Science.gov (United States)

    Rambousky, R.; Nitsch, J.; Tkachenko, S.

    2015-11-01

    By applying the Transmission-Line Super Theory (TLST) to a practical transmission-line configuration (two risers and a horizontal part of the line parallel to the ground plane) it is elaborated under which physical and geometrical conditions the horizontal part of the transmission-line can be represented by a classical telegrapher equation with a sufficiently accurate description of the physical properties of the line. The risers together with the part of the horizontal line close to them are treated as separate lines using the TLST. Novel frequency and local dependent reflection coefficients are introduced to take into account the action of the bends and their radiation. They can be derived from the matrizant elements of the TLST solution. It is shown that the solution of the resulting network and the TLST solution of the entire line agree for certain line configurations. The physical and geometrical parameters for these corresponding configurations are determined in this paper.

  11. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line which...

  12. Tornado risk model for transmission line design

    CSIR Research Space (South Africa)

    Milford, RV

    1997-11-01

    Full Text Available per year striking the section of transmission line of length L k (or the probability of a strike, Psk (F = FJ within an area A can then be expressed as: P~k(F = Fi) = AliLk _ N nilL ~S i k = LkpP(F = Fi)li...

  13. Stabilizing Fiber-Optic Transmission Lines

    Science.gov (United States)

    Lutes, G. F.; Lau, K. Y.

    1984-01-01

    Voltage-controlled optical phase shifter is key. Optical phase shifter stabilizes propagation delay of fiber-optic transmission line by compensating for temperature and pressure effects. Applicable to phased array antenna systems and very-long-baseline interferometer distribution systems.

  14. Circuit QED with hybrid metamaterial transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Ruloff, Stefan; Taketani, Bruno; Wilhelm, Frank [Theoretical Physics, Universitaet des Saarlandes, Saarbruecken (Germany)

    2016-07-01

    We're working on the theory of metamaterials providing some interesting results. The negative refraction index causes an opposite orientation of the wave vector k and the Poynting vector S of the travelling waves. Hence the metamaterial has a falling dispersion relation ∂ω(k)/∂k < 0 implying that low frequencies correspond to short wavelengths. Metamaterials are simulated by left-handed transmission lines consisting of discrete arrays of series capacitors and parallel inductors to ground. Unusual physics arises when right-and left-handed transmission lines are coupled forming a hybrid metamaterial transmission line. E.g. if a qubit is placed in front of a hybrid metamaterial transmission line terminated in an open circuit, the spontaneous emission rate is weakened or unaffected depending on the transition frequency of the qubit. Some other research interests are the general analysis of metamaterial cavities and the mode structure of hybrid metamaterial cavities for QND readout of multi-qubit operators. Especially the precise answer to the question about the definition of the mode volume of a metamaterial cavity is one of our primary goals.

  15. Artificial Dielectric Shields for Integrated Transmission Lines

    NARCIS (Netherlands)

    Ma, Y.; Rejaei, B.; Zhuang, Y.

    2008-01-01

    We present a novel shielding method for on-chip transmission lines built on conductive silicon substrates. The shield consists of an artificial dielectric with a very high in-plane dielectric constant, built from two patterned metal layers isolated by a very thin dielectric film. Inserted below an

  16. Stub resonators Transmission - line - based water sensors

    NARCIS (Netherlands)

    Hoog-Antonyuk, N.A.

    2014-01-01

    The research presented in this thesis describes practical investigations in using stub resonator (as a transmission line) technology for different (on-) inline sensor applications in the field of water technology. In addition, a substantial part of the research has been devoted to provide an

  17. Transmission line for S-band masers

    Science.gov (United States)

    Clauss, R. C.; Wiebe, E. R.

    1975-01-01

    Transmission-line is coaxial. Its outer conductor is made of thin-wall stainless-steel tube; inside is plated with 0.0025 mm copper and 0.0003 mm gold. This combination gives little microwave loss and adequate thermal isolation.

  18. Optimization of Normal Regimes of Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    E. G. Pospelov

    2006-01-01

    Full Text Available In order to optimize normal regimes of the power transmission lines notions of economic, maximum and the largest efficiency of a transmission line are used. Power losses by wire corona transmission losses are considered.

  19. Coaxial tube array space transmission line characterization

    Science.gov (United States)

    Switzer, Colleen A.; Bents, David J.

    1987-01-01

    The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance.

  20. Transmission line environmental assessment guidance document

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, J.; Pentecost, E.; Muzzarelli, J.

    1994-01-01

    Since 1939, U.S. utility companies have been required to obtain a Presidential Permit to construct electric transmission lines that cross a U.S. border and connect with a foreign utility. The purpose of this document is to provide Presidential Permit applicants with two types of guidance: (1) on the type of environmental and project descriptive information needed to assess the potential impacts of the proposed and alternative actions and (2) on compliance with applicable federal and state regulations. The main three chapters present information on the purpose and content of this document (Chapter 1); legislative, regulatory, and consultation requirements for transmission line interconnect projects (Chapter 2); and identification of basic transmission system design parameters and environmental data requirements for analysis of potential impacts of the proposed action (Chapter 3). Chapter 3 also includes information on possible techniques or measures to mitigate impacts. Appendix A presents an overview of NEPA requirements and DOE`s implementing procedures. Appendix B summarizes information on legislation that may be applicable to transmission line projects proposed in Presidential Permit applications.

  1. 49 CFR 192.179 - Transmission line valves.

    Science.gov (United States)

    2010-10-01

    ... atmosphere without hazard and, if the transmission line is adjacent to an overhead electric line, so that the gas is directed away from the electrical conductors. (d) Offshore segments of transmission lines must...

  2. 7 CFR 1726.77 - Substation and transmission line construction.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Substation and transmission line construction. 1726... and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract... substation and transmission line construction (including minor modifications or improvements), exclusive of...

  3. Flux qubit to a transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Haeberlein, Max; Baust, Alexander; Zhong, Ling; Gross, Rudolf [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Nanosystems Initiative Munich (NIM), Muenchen (Germany); Anderson, Gustav; Wang, Lujun; Eder, Peter; Fischer, Michael; Goetz, Jan; Xie, Edwar; Schwarz, Manuel; Wulschner, Karl Friedrich; Deppe, Frank; Fedorov, Kirill; Huebl, Hans; Menzel, Edwin [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Marx, Achim [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany)

    2015-07-01

    Within the last decade, superconducting qubits coupled to microwave resonators have been extensively studied within the framework of quantum electrodynamics. Ultimately, quantum computing seems within reach in such architectures. However, error correction schemes are necessary to achieve the required fidelity in multi-qubit operations, drastically increasing the number of qubits involved. In this work, we couple a flux qubit to a transmission line where it interacts with itinerant microwave photons granting access to all-optical quantum computing. In this approach, travelling photons generate entanglement between two waveguides, containing the qubit information. In this presentation, we show experimental data on flux qubits coupled to transmission lines. Furthermore, we will discuss entanglement generation between two separate paths.

  4. Tuners For Coplanar-Strip Transmission Lines

    Science.gov (United States)

    Mcgrath, William R.; Lubecke, Victor M.; Rutledge, David B.

    1993-01-01

    Sliding radio-frequency short circuits easily adjusted for optimum impedance. Tuning elements developed for use in planar integrated circuits operating at frequencies from about 10 to more than 1,000 GHz. Purpose of such adjustment to adjust impedance presented to circuit connected to nonshorted end of transmission line and thereby optimizes performance of circuit. Mixers, oscillators, amplifiers, couplers, and phase shifters among circuits improved by incorporating tuners of this type.

  5. Self-Shielding Of Transmission Lines

    Energy Technology Data Exchange (ETDEWEB)

    Christodoulou, Christos [Univ. of New Mexico, Albuquerque, NM (United States)

    2017-03-01

    The use of shielding to contend with noise or harmful EMI/EMR energy is not a new concept. An inevitable trade that must be made for shielding is physical space and weight. Space was often not as much of a painful design trade in older larger systems as they are in today’s smaller systems. Today we are packing in an exponentially growing number of functionality within the same or smaller volumes. As systems become smaller and space within systems become more restricted, the implementation of shielding becomes more problematic. Often, space that was used to design a more mechanically robust component must be used for shielding. As the system gets smaller and space is at more of a premium, the trades starts to result in defects, designs with inadequate margin in other performance areas, and designs that are sensitive to manufacturing variability. With these challenges in mind, it would be ideal to maximize attenuation of harmful fields as they inevitably couple onto transmission lines without the use of traditional shielding. Dr. Tom Van Doren proposed a design concept for transmission lines to a class of engineers while visiting New Mexico. This design concept works by maximizing Electric field (E) and Magnetic Field (H) field containment between operating transmission lines to achieve what he called “Self-Shielding”. By making the geometric centroid of the outgoing current coincident with the return current, maximum field containment is achieved. The reciprocal should be true as well, resulting in greater attenuation of incident fields. Figure’s 1(a)-1(b) are examples of designs where the current centroids are coincident. Coax cables are good examples of transmission lines with co-located centroids but they demonstrate excellent field attenuation for other reasons and can’t be used to test this design concept. Figure 1(b) is a flex circuit design that demonstrate the implementation of self-shielding vs a standard conductor layout.

  6. 75 FR 66750 - Albany-Eugene Transmission Line Rebuild Project

    Science.gov (United States)

    2010-10-29

    ... Bonneville Power Administration Albany-Eugene Transmission Line Rebuild Project AGENCY: Bonneville Power... Transmission Line in Lane and Linn counties, Oregon. The deteriorated condition of this 70-year old line... Transmission Line Rebuild Project EIS and requesting comments about the potential environmental impacts it...

  7. Integral equations formulation of plasmonic transmission lines.

    Science.gov (United States)

    Sallam, Mai O; Vandenbosch, Guy A E; Gielen, Georges; Soliman, Ezzeldin A

    2014-09-22

    In this paper, a comprehensive integral equation formulation of plasmonic transmission lines is presented for the first time. Such lines are made up of a number of metallic strips with arbitrary shapes and dimensions immersed within a stack of planar dielectric or metallic layers. These lines support a number of propagating modes. Each mode has its own phase constant, attenuation constant, and field distribution. The presented integral equation formulation is solved using the Method of Moments (MoM). It provides all the propagation characteristics of the modes. The new formulation is applied to a number of plasmonic transmission lines, such as: single rectangular strip, horizontally coupled strips, vertically coupled strips, triangular strip, and circular strip. The numerical study is performed in the frequency (wavelength) range of 150-450 THz (0.66-2.0 μm). The results of the proposed technique are compared with those obtained using Lumerical mode solution, and CST. Very good agreement has been observed. The main advantage of the MoM is its intrinsic speed for this type of problem compared to general purpose solvers.

  8. Geotechnical assessments of upgrading power transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Andrew [Coffey Geotechnics Ltd., Harrogate (United Kingdom)

    2012-11-01

    One of the consequences of increasing demand for energy is a corresponding requirement for increased energy distribution. This trend is likely to be magnified by the current tendency to generate power in locations remote from centres of population. New power transmission routes are expensive and awkward to develop, and there are therefore benefits to be gained by upgrading existing routes. However, this in turn raises problems of a different nature. The re-use of any structure must necessarily imply the acceptance of unknowns. The upgrading of transmission lines is no exception to this, particularly when assessing foundations, which in their nature are not visible. A risk-based approach is therefore used. This paper describes some of the geotechnical aspects of the assessment of electric power transmission lines for upgrading. It briefly describes the background, then discusses some of the problems encountered and the methods used to address them. These methods are based mainly on information obtained from desk studies and walkover surveys, with a limited amount of intrusive investigation. (orig.)

  9. Dispersion-free radial transmission lines

    Science.gov (United States)

    Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA

    2011-04-12

    A dispersion-free radial transmission line ("DFRTL") preferably for linear accelerators, having two plane conductors each with a central hole, and an electromagnetically permeable material ("EPM") between the two conductors and surrounding a channel connecting the two holes. At least one of the material parameters of relative magnetic permeability, relative dielectric permittivity, and axial width of the EPM is varied as a function of radius, so that the characteristic impedance of the DFRTL is held substantially constant, and pulse transmission therethrough is substantially dispersion-free. Preferably, the EPM is divided into concentric radial sections, with the varied material parameters held constant in each respective section but stepwise varied between sections as a step function of the radius. The radial widths of the concentric sections are selected so that pulse traversal time across each section is the same, and the varied material parameters of the concentric sections are selected to minimize traversal error.

  10. Application of ANFIS for Distance Relay Protection in Transmission Line

    National Research Council Canada - National Science Library

    Azriyenni Azriyenni; Mohd Wazir Mustafa

    2015-01-01

    .... There was applied ANFIS for distance relay protection particularly for transmission line. If a fault occurs during the transmission line identification caused by unwanted fault thus the power delivery to the consumer becomes not going well...

  11. Optoelectronic line transmission an introduction to fibre optics

    CERN Document Server

    Tricker, Raymond L

    2013-01-01

    Optoelectronic Line Transmission: An Introduction to Fibre Optics presents a basic introduction as well as a background reference manual on fiber optic transmission. The book discusses the basic principles of optical line transmission; the advantages and disadvantages of optical fibers and optoelectronic signalling; the practical applications of optoelectronics; and the future of optoelectronics. The text also describes the theories of optical line transmission; fibers and cables for optical transmission; transmitters including light-emitting diodes and lasers; and receivers including photodi

  12. Transmission line including support means with barriers

    Science.gov (United States)

    Cookson, Alan H.

    1982-01-01

    A gas insulated transmission line includes an elongated outer sheath, a plurality of inner conductors disposed within and extending along the outer sheath, and an insulating gas which electrically insulates the inner conductors from the outer sheath. A support insulator insulatably supports the inner conductors within the outer sheath, with the support insulator comprising a main body portion including a plurality of legs extending to the outer sheath, and barrier portions which extend between the legs. The barrier portions have openings therein adjacent the main body portion through which the inner conductors extend.

  13. Giant vacuum forces via transmission lines.

    Science.gov (United States)

    Shahmoon, Ephraim; Mazets, Igor; Kurizki, Gershon

    2014-07-22

    Quantum electromagnetic fluctuations induce forces between neutral particles, known as the van der Waals and Casimir interactions. These fundamental forces, mediated by virtual photons from the vacuum, play an important role in basic physics and chemistry and in emerging technologies involving, e.g., microelectromechanical systems or quantum information processing. Here we show that these interactions can be enhanced by many orders of magnitude upon changing the character of the mediating vacuum modes. By considering two polarizable particles in the vicinity of any standard electric transmission line, along which photons can propagate in one dimension, we find a much stronger and longer-range interaction than in free space. This enhancement may have profound implications on many-particle and bulk systems and impact the quantum technologies mentioned above. The predicted giant vacuum force is estimated to be measurable in a coplanar waveguide line.

  14. 77 FR 35366 - Albany-Eugene Transmission Line Rebuild Project

    Science.gov (United States)

    2012-06-13

    ... Bonneville Power Administration Albany-Eugene Transmission Line Rebuild Project AGENCY: Bonneville Power..., based on the Albany-Eugene Transmission Line Rebuild Project (DOE/EIS-0457, March 2012). BPA has decided to rebuild a 32-mile section of the existing Albany-Eugene 115- kV transmission line that extends...

  15. 75 FR 25195 - Kake to Petersburg Transmission Line Intertie Project

    Science.gov (United States)

    2010-05-07

    ... Forest Service Kake to Petersburg Transmission Line Intertie Project AGENCY: Forest Service, USDA. ACTION... operate a new electric transmission line intertie that would extend west across the Tongass National... transmission line that would transmit power at either 69 or 138 kilovolt (kV) and consist of single wood pole...

  16. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Remedial measures: Transmission lines. 192.485... Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for the...

  17. 32 CFR 644.431 - Power transmission lines.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to the...

  18. 49 CFR 192.709 - Transmission lines: Record keeping.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Record keeping. 192.709... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.709 Transmission lines: Record keeping. Each operator shall maintain the following records for transmission lines...

  19. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Testing of repairs. 192.719... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.719 Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line is...

  20. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance: Transmission lines. 192.745... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.745 Valve maintenance: Transmission lines. (a) Each transmission line valve that might be required during any emergency...

  1. 49 CFR 192.707 - Line markers for mains and transmission lines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Line markers for mains and transmission lines. 192... § 192.707 Line markers for mains and transmission lines. (a) Buried pipelines. Except as provided in... buried main and transmission line: (1) At each crossing of a public road and railroad; and (2) Wherever...

  2. A radial transmission line material measurement apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Warne, L.K.; Moyer, R.D.; Koontz, T.E.; Morris, M.E.

    1993-05-01

    A radial transmission line material measurement sample apparatus (sample holder, offset short standards, measurement software, and instrumentation) is described which has been proposed, analyzed, designed, constructed, and tested. The purpose of the apparatus is to obtain accurate surface impedance measurements of lossy, possibly anisotropic, samples at low and intermediate frequencies (vhf and low uhf). The samples typically take the form of sections of the material coatings on conducting objects. Such measurements thus provide the key input data for predictive numerical scattering codes. Prediction of the sample surface impedance from the coaxial input impedance measurement is carried out by two techniques. The first is an analytical model for the coaxial-to-radial transmission line junction. The second is an empirical determination of the bilinear transformation model of the junction by the measurement of three full standards. The standards take the form of three offset shorts (and an additional lossy Salisbury load), which have also been constructed. The accuracy achievable with the device appears to be near one percent.

  3. Survey of transmission line corridors. [Data on delays in transmission line construction

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-05

    The intent of this study is to determine the extent of delays experienced in planning and constructing transmission lines in the continental United States. The reasons for the delays are identified for each line studied and their effect on the total electrical system is sought. Data was collected for 136 different lines either recently built or currently under study. Statistics were developed for each line in several categories and comparisons of lines delayed were made by company, area served and generation capacity. From the study presented here it was found that: right-of-way acquisition procedures including condemnation and easement negotiation practices delay more projects than local, state and federal regulatory requirements combined; load growth reductions particularly in the east have reduced the impact of regulatory delays; the south, southeast and southwestern areas of the country experience fewer delays in constructing transmission lines than the more populated states, and the cost for corridor delays was responded to for only 17 of the 142 projects surveyed. By far the most costly delay is the expense of condemning land for transmission right-of-way.

  4. Characterization of superconducting transmission line resonators

    Energy Technology Data Exchange (ETDEWEB)

    Goetz, Jan; Summer, Philipp; Meier, Sebastian; Haeberlein, Max; Wulschner, Karl Friedrich; Eder, Peter; Fischer, Michael; Schwarz, Manuel; Deppe, Frank; Fedorov, Kirill; Huebl, Hans; Menzel, Edwin [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Krawczyk, Marta; Marx, Achim [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Baust, Alexander; Xie, Edwar; Zhong, Ling; Gross, Rudolf [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Nanosystems Initiative Munich (NIM), Muenchen (Germany)

    2015-07-01

    Superconducting transmission line resonators are widely used in circuit quantum electrodynamics experiments as quantum bus or storage devices. For these applications, long coherence times, which can be linked to the internal quality factor of the resonators, are crucial. Here, we show a systematic study of the internal quality factor of niobium thin film resonators. We analyze different cleaning methods and substrate parameters for coplanar waveguide as well as microstrip geometries. In addition, we investigate the impact of a niobium-aluminum interface which is necessary for galvanically coupled flux qubits made from aluminum. This interface can be avoided by fabricating the complete resonator-qubit structure using Al/AlO{sub x}/Al technology during fabrication.

  5. Transmission line matrix model for ultrasonic imaging

    Science.gov (United States)

    Ciocan, Razvan; Ida, Nathan; Driscoll, Diana

    2002-06-01

    A transmission-line matrix (TLM) model was developed to simulate the ultrasound propagation in the multi-layer structures. The spatial resolution of the proposed model is better than tenth wavelength. The numerical modeling is carried-out for frequencies that are usually used in ultrasound imagery (3.5 - 25MHz). The acoustic impedance profile of multi-layer structures considered are similar to those found in nondestructive evaluation and in medical imaging. The structures modeled are: brazed joints, stomach and colon walls. Structures with artificial flaws are also modeled. A comparison between real images and numerical generated ones is provided for each considered structure. Both frequency and time domain responses are obtained from the structures under investigation. Both single and array transducer techniques are modeled and their performances are evaluated for the proposed structures. Different shapes for the incident pulse are considered in numerically generated images.

  6. 49 CFR 192.705 - Transmission lines: Patrolling.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and other...

  7. Estimating magnetic fields of homes near transmission lines in the California Power Line Study.

    Science.gov (United States)

    Vergara, Ximena P; Kavet, Robert; Crespi, Catherine M; Hooper, Chris; Silva, J Michael; Kheifets, Leeka

    2015-07-01

    The California Power Line Study is a case-control study investigating the relation between residences near transmission lines and risk of childhood leukemia. It includes 5788 childhood leukemia cases and 5788 matched primary controls born between 1986 and 2007. We describe the methodology for estimating magnetic fields at study residences as well as for characterizing sources of uncertainty in these estimates. Birth residences of study subjects were geocoded and their distances to transmission lines were ascertained. 302 residences were deemed sufficiently close to transmission lines to have non-zero magnetic fields attributable to the lines. These residences were visited and detailed data, describing the physical configuration and dimensions of the lines contributing to the magnetic field at the residence, were collected. Phasing, loading, and directional load flow data for years of birth and diagnosis for each subject as well as for the day of site visit were obtained from utilities when available; when yearly average load for a particular year was not available, extrapolated values based on expert knowledge and prediction models were obtained. These data were used to estimate the magnetic fields at the center, closest and farthest point of each residence. We found good correlation between calculated fields and spot measurements of fields taken on site during visits. Our modeling strategies yielded similar calculated field estimates, and they were in high agreement with utility extrapolations. Phasing was known for over 90% of the lines. Important sources of uncertainty included a lack of information on the precise location of residences located within apartment buildings or other complexes. Our findings suggest that we were able to achieve high specificity in exposure assessment, which is essential for examining the association between distance to or magnetic fields from power lines and childhood leukemia risk. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Radio frequency communication system utilizing radiating transmission lines

    Science.gov (United States)

    Struven, Warren C.

    1984-01-01

    A radio communication system for use in tunnels, mines, buildings or other shielded locations in which a pair of radiating transmission lines (30), (31) extend through such location in spaced coextensive relation to each other. Each transmission line (30), (31) has at least one unidirectional amplifier (32), (33) interposed therein with the sense of the unidirectional amplifier (32) of one transmission line (30) being opposite to the sense of the unidirectional amplifier (33) of the other transmission line (31). Each of the amplifiers (32), (33) has a gain which is less than the coupling loss between the transmission lines (30), (31). Two or more mobile transceivers (35) in the location served by the system are coupled to the transmission lines (30), (31) by electromagnetic wave propagation in space in order to communicate directly with each other at a given radio frequency within the frequency range of the system.

  9. Modelling of Attenuation and Crosstalk of Cascaded Transmission Lines

    Directory of Open Access Journals (Sweden)

    Pavel Lafata

    2011-01-01

    Full Text Available This paper deals with the measurements and modelling of attenuation and near-end (NEXT and far-end (FEXT crosstalk for cascaded metallic transmission lines. The transmission parameters of homogenous metallic line can be easily described by telegraph equations or cascade matrix; there are also several models for NEXT and FEXT frequency dependence. But these models and equations could not be applied in the situation of two or more different cascaded transmission lines, because these cascaded lines do not meet the essential condition of overall homogenous transmission line. However in such case, it is still possible to estimate the overall transmission characteristics of the whole combination thanks to the characteristics of each separate element. This paper brings the description of complex measurements performed for the combination of three different metallic cables and based on these measurements, several conclusions about the possibilities of modelling the attenuation and NEXT and FEXT crosstalk for cascaded transmission lines are presented.

  10. Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources.

    Science.gov (United States)

    Reale, D V; Parson, J M; Neuber, A A; Dickens, J C; Mankowski, J J

    2016-03-01

    A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV-55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

  11. Active microwave negative-index metamaterial transmission line with gain.

    Science.gov (United States)

    Jiang, Tao; Chang, Kihun; Si, Li-Ming; Ran, Lixin; Xin, Hao

    2011-11-11

    We studied the active metamaterial transmission line at microwave frequency. The active composite right-handed or left-handed transmission line was designed to incorporate a germanium tunnel diode with a negative differential resistance property as the gain device at the unit cell level. Measurements of the fabricated planar transmission line structures with one-, two-, and three-unit cells showed that the addition of the dc pumped tunnel diodes not only provided gain but also maintained the left handedness of the transmission line metamaterial. Simulation results agree well with experimental observation. This work demonstrated that negative index material can be obtained with a net gain when an external source is incorporated.

  12. Flux Noise in a Superconducting Transmission Line

    Science.gov (United States)

    Vasko, F. T.

    2017-08-01

    We study a superconducting transmission line (TL) formed by distributed L C oscillators and excited by external magnetic fluxes which are aroused from random magnetization (A ) placed in substrate or (B ) distributed at interfaces of a two-wire TL. The low-frequency dynamics of a random magnetic field is described based on the diffusion Langevin equation with a short-range source caused by (a ) a random amplitude or (b ) the gradient of magnetization. For a TL modeled as a two-port network with open and shorted ends, the effective magnetic flux at the open end has nonlocal dependency on noise distribution along the TL. The flux-flux correlation function is evaluated and analyzed for the regimes (A a ), (A b ), (B a ), and (B b ). Essential frequency dispersion takes place around the inverse diffusion time of random flux along the TL. Typically, noise effect increases with size faster than the area of the TL. The flux-flux correlator can be verified both via the population relaxation rate of the qubit, which is formed by the Josephson junction shunted by the TL with flux noises, and via random voltage at the open end of the TL.

  13. Experiments of a monolithic radial transmission line.

    Science.gov (United States)

    Mao, C; Wang, X; Zou, X; Lehr, J

    2016-11-01

    This paper presents the experimental results of a monolithic radial transmission line (MRTL) that may be used in pulsed power generators and microwave devices. The MRTL with a hyperbolic impedance profile is 508 mm in radius, corresponding to a one-way transit time of 15 ns for the electromagnetic wave. In the experiments, up to twenty identical voltage pulses, 10 ns in FWHM and 2 ns in rise-time, were fed into the MRTL through 20 input BNC connectors that are uniformly distributed along the outer circumference of the MRTL. It was found that the amplitude of the voltage from the output BNC connector located in the center of the MRTL is nearly proportional to the total number of the input branches. The effect of the failure modes on the output voltage was investigated. For the MRTL driven by 20 input branches, while the open-circuit or short-circuit even in one input branch considerably decreases the amplitude of the output voltage, the jitter shorter than 2 ns in 3 input branches makes no obvious effect on the output voltage.

  14. Magnetic insulation of electron flow in curved transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Geary, J. [Berkeley Research Associates, Springfield, VA (United States); Grossmann, J. [Naval Research Lab., Washington, DC (United States); Swanekamp, S. [Science Applications International Corp., McLean, VA (United States)

    1994-12-31

    Magnetically insulated transmission lines with curved sections are often used to transport electrical power in pulsed power generators. These sections can have substantial current losses, which are difficult to model accurately with circuit codes. The authors study the electron flow in curved transmission lines with the particle-in-cell code ISIS. ISIS is formulated using nonorthogonal boundary-fitted coordinates that allow the computational mesh to conform to the conductors. The authors examine a triplate transmission line with a 90{degree} degree bend. Two dimensional simulations with and without the bend show that the critical current for magnetic insulation agrees with the predictions from Brillouin flow within a constant factor of 1.6. They also find that the impedance of an electron beam diode decreases when the diode is attached to a transmission line with a bend compared to when the same diode is attached to a straight transmission line. This appears to result from additional power reflection off the bend in the transmission line and from changes in the vacuum electron flow launched in the bend and the diode. They will also examine the transition from a coaxial to a triplate transmission line.

  15. A Parametric Study of Nonlinear Seismic Response Analysis of Transmission Line Structures

    OpenAIRE

    Li Tian; Yanming Wang; Zhenhua Yi; Hui Qian

    2014-01-01

    A parametric study of nonlinear seismic response analysis of transmission line structures subjected to earthquake loading is studied in this paper. The transmission lines are modeled by cable element which accounts for the nonlinearity of the cable based on a real project. Nonuniform ground motions are generated using a stochastic approach based on random vibration analysis. The effects of multicomponent ground motions, correlations among multicomponent ground motions, wave travel, coherency ...

  16. Silicon photonics plasma-modulators with advanced transmission line design.

    Science.gov (United States)

    Merget, Florian; Azadeh, Saeed Sharif; Mueller, Juliana; Shen, Bin; Nezhad, Maziar P; Hauck, Johannes; Witzens, Jeremy

    2013-08-26

    We have investigated two novel concepts for the design of transmission lines in travelling wave Mach-Zehnder interferometer based Silicon Photonics depletion modulators overcoming the analog bandwidth limitations arising from cross-talk between signal lines in push-pull modulators and reducing the linear losses of the transmission lines. We experimentally validate the concepts and demonstrate an E/O -3 dBe bandwidth of 16 GHz with a 4V drive voltage (in dual drive configuration) and 8.8 dB on-chip insertion losses. Significant bandwidth improvements result from suppression of cross-talk. An additional bandwidth enhancement of ~11% results from a reduction of resistive transmission line losses. Frequency dependent loss models for loaded transmission lines and E/O bandwidth modeling are fully verified.

  17. Propagation behaviour of overhead transmission lines

    African Journals Online (AJOL)

    leading to low Signal to Noise Ratios (SNR) and consequent reduced propagation conditions require specific transmission and reception conditions over the .... where, I is the load current, t, the ambient temperature, o, the resistance temperature coefficient of conductor at 0 °C, r, the conductor resistance per metre at 0 °C, a, ...

  18. Bottlenecks reduction using superconductors in high voltage transmission lines

    Directory of Open Access Journals (Sweden)

    Daloub Labib

    2016-01-01

    Full Text Available Energy flow bottlenecks in high voltage transmission lines known as congestions are one of the challenges facing power utilities in fast developing countries. Bottlenecks occur in selected power lines when transmission systems are operated at or beyond their transfer limits. In these cases, congestions result in preventing new power supply contracts, infeasibility in existing contracts, price spike and market power abuse. The “Superconductor Technology” in electric power transmission cables has been used as a solution to solve the problem of bottlenecks in energy transmission at high voltage underground cables and overhead lines. The increase in demand on power generation and transmission happening due to fast development and linked to the intensive usage of transmission network in certain points, which in turn, lead to often frequent congestion in getting the required power across to where it is needed. In this paper, a bottleneck in high voltage double overhead transmission line with Aluminum Conductor Steel Reinforced was modeled using conductor parameters and replaced by Gap-Type Superconductor to assess the benefit of upgrading to higher temperature superconductor and obtain higher current carrying capacity. This proved to reduce the high loading of traditional aluminum conductors and allow more power transfer over the line using superconductor within the same existing right-of-way, steel towers, insulators and fittings, thus reducing the upgrade cost of building new lines.

  19. Coupled Transmission Lines as Impedance Transformer

    DEFF Research Database (Denmark)

    Jensen, Thomas; Zhurbenko, Vitaliy; Krozer, Viktor

    2007-01-01

    A theoretical investigation of the use of a coupled line section as an impedance transformer is presented. We show how to properly select the terminations of the coupled line structures for effective matching of real and complex loads in both narrow and wide frequency ranges. The corresponding....... Wideband matching performance with relative bandwidth beyond 100% and return loss > 20 dB is demonstrated both theoretically and experimentally. Good agreement is achieved between the measured and predicted performance of the coupled line transformer section....

  20. Josephson junctions loaded by transmission lines: a revisited problem.

    Science.gov (United States)

    Ranfagni, Anedio; Cacciari, Ilaria; Moretti, Paolo

    2011-11-01

    The problem of evaluating dissipative effects in Josephson junctions loaded by transmission lines is reexamined, for either the symmetric or the asymmetric case, with particular consideration of the time domain in which the interaction between junction and load system occurs.

  1. Artificial neural networks in high voltage transmission line problems

    Science.gov (United States)

    Ekonomou, L.; Kontargyri, V. T.; Kourtesi, St.; Maris, T. I.; Stathopulos, I. A.

    2007-07-01

    According to the literature high voltage transmission line problems are faced using conventional analytical methods, which include in most cases empirical and/or approximating equations. Artificial intelligence and more specifically artificial neural networks (ANN) are addressed in this work, in order to give accurate solutions to high voltage transmission line problems using in the calculations only actual field data. Two different case studies are studied, i.e., the estimation of critical flashover voltage on polluted insulators and the estimation of lightning performance of high voltage transmission lines. ANN models are developed and are tested on operating high voltage transmission lines and polluted insulators, producing very satisfactory results. These two ANN models can be used in electrical engineers' studies aiming at the more effective protection of high voltage equipment.

  2. Single transmission line interrogated multiple channel data acquisition system

    Science.gov (United States)

    Fasching, George E.; Keech, Jr., Thomas W.

    1980-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensor circuits each monitors a specific process variable and each transmits measurement values over a single transmission line to a master interrogating station when addressed by said master interrogating station. Typically, as many as 330 remote stations may be parallel connected to the transmission line which may exceed 7,000 feet. The interrogation rate is typically 330 stations/second. The master interrogating station samples each station according to a shared, charging transmit-receive cycle. All remote station address signals, all data signals from the remote stations/sensors and all power for all of the remote station/sensors are transmitted via a single continuous terminated coaxial cable. A means is provided for periodically and remotely calibrating all remote sensors for zero and span. A provision is available to remotely disconnect any selected sensor station from the main transmission line.

  3. Electrical and Biological Effects of Transmission Lines: A Review.

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jack M.

    1989-06-01

    This review describes the electrical properties of a-c and d-c transmission lines and the resulting effects on plants, animals, and people. Methods used by BPA to mitigate undesirable effects are also discussed. Although much of the information in this review pertains to high-voltage transmission lines, information on distribution lines and electrical appliances is included. The electrical properties discussed are electric and magnetic fields and corona: first for alternating-current (a-c) lines, then for direct current (d-c).

  4. Multimode circuit quantum electrodynamics with hybrid metamaterial transmission lines.

    Science.gov (United States)

    Egger, D J; Wilhelm, F K

    2013-10-18

    Quantum transmission lines are central to superconducting and hybrid quantum computing. In this work we show how coupling them to a left-handed transmission line allows circuit QED to reach a new regime: multimode ultrastrong coupling. Out of the many potential applications of this novel device, we discuss the preparation of multipartite entangled states and the simulation of the spin-boson model where a quantum phase transition is reached up to finite size effects.

  5. Corrugated outer sheath gas-insulated transmission line

    Science.gov (United States)

    Kemeny, George A.; Cookson, Alan H.

    1981-01-01

    A gas-insulated transmission line includes two transmission line sections each of which are formed of a corrugated outer housing enclosing an inner high-voltage conductor disposed therein, with insulating support means supporting the inner conductor within the outer housing and an insulating gas providing electrical insulation therebetween. The outer housings in each section have smooth end sections at the longitudinal ends thereof which are joined together by joining means which provide for a sealing fixed joint.

  6. Stabilizing control for power converters connected to transmission lines

    NARCIS (Netherlands)

    Zainea, Marius; Schaft, Arjan van der; Buisson, Jean

    2007-01-01

    This paper proposes a switching control strategy for the set-point stabilization of a power converter connected via a transmission line to a resistive load. The strategy employs a Lyapunov function that is directly based on energy considerations of the power converter, as well as of the transmission

  7. Transients induced by pulses on transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Canavero, F.G.; Daniele, V.; Graglia, R.D. (Politecnico di Torino, Turin (Italy). Dipt. di Elettronica)

    1989-02-01

    This paper deals with the derivation of analytical expressions for transients in lossless lines loaded by linear non-reactive elements and excited by interfering disturbances. The telegrapher's equation model is adopted and the equivalent circuit of the n-conductor line is shown to the valid for both internal and external sources. Crosstalk is accounted for via the coupled equations of the line while the external interference is represented by a source of electromagnetic waves. Closed-form solutions in the time domain are derived, and therefore no numerical inversion of Laplace transform is required in the solution process. Our results, besides being directly applicable in many practical cases, provide an insight into the electromagnetic mechanisms of the interferences and constitute a valid check for more complex all-numerical simulations.

  8. Application of EPON Technology in Transmission Line Video Monitoring

    Directory of Open Access Journals (Sweden)

    Xia Zongze

    2015-01-01

    Full Text Available The operating condition of transmission lines directly determines the efficiency of the power system. Therefore, faced with a complex operating environment, it is extremely important to protect transmission line video monitoring. At present, the technology widely used in the power distribution and network communication in domestic power industry is EPON technology. This technology has a broad application prospect on the transmission of electrical circuit video monitoring information. On this basis, this paper carries out a further research on the application of EPON technology in transmission line video monitoring. This paper firstly proposes the design principle of transmission line video monitoring, and on this basis, it carries out a comparative analysis of merits and demerits of different types of EPON networking schemes. In addition, quantification is given for the EPON networking power consumption, so as to obtain a complete EPON combining scheme which is combined with specific examples to validate, and finally realize that the EPON technology has a certain application value because it is in line with various indicators after application in transmission line video monitoring.

  9. Impedance matching with an adjustable segmented transmission line.

    Science.gov (United States)

    Qian, Chunqi; Brey, William W

    2009-07-01

    A capability for impedance matching between the RF probe and the spectrometer is a standard requirement for NMR. Both lumped element and branched transmission line methods are widely used for this purpose. Here, we propose to use the segmented transmission line structure which is well known in wireless communications. It relies upon reflections between transmission lines of different characteristic impedances that are serially connected to match the impedance of a coil or resonator to the characteristic impedance of the NMR spectrometer. In our implementation, two quarter wave length dielectric slugs are placed within a coaxial transmission line. Adjustment of the positions of the slugs allows the variable tuning and matching needed for NMR probes, eliminating the need for variable capacitors and inductors. As a demonstration of the usefulness of this approach, we have incorporated a variable segmented transmission line into a home-built Variable Angle Spinning probe. Finally, we discuss the range of possible application for segmented transmission line networks in NMR probe design.

  10. A Generalized Lossy Transmission-Line Model for Tunable Graphene-Based Transmission Lines with Attenuation Phenomenon

    Science.gov (United States)

    Wu, Yongle; Qu, Meijun; Liu, Yuanan

    2016-08-01

    To investigate the frequency shift phenomenon by inserting graphene, a generalized lossy transmission-line model and the related electrical parameter-extraction theory are proposed in this paper. Three kinds of graphene-based transmission lines with attenuation phenomenon including microstrip line, double-side parallel strip line, and uniplanar coplanar waveguide are analyzed under the common conditions where different chemical potentials are loaded on graphene. The values of attenuation constant and phase constant, and the real and imaginary parts of the characteristic impedance of transmission lines are extracted to analyze in details. When the attenuation constant and the reactance part of the characteristic impedance are approximately equal to zero, this kind of transmission line has low or zero insertion loss. On the contrary, the transmission line is under the radiation mode with obvious insertion loss. The phase constant changes linearly under the transmission mode and can be varied with changing of chemical potentials which attributes to the property of frequency tunability. Furthermore, a bandwidth reconfigurable uniplanar coplanar waveguide power divider is simulated to demonstrate that this theory can be applied to the design of three-port devices. In summary, this work provides a strong potential approach and design theory to help design other kinds of terahertz and mid-infrared reconfigurable devices.

  11. A Generalized Lossy Transmission-Line Model for Tunable Graphene-Based Transmission Lines with Attenuation Phenomenon.

    Science.gov (United States)

    Wu, Yongle; Qu, Meijun; Liu, Yuanan

    2016-08-24

    To investigate the frequency shift phenomenon by inserting graphene, a generalized lossy transmission-line model and the related electrical parameter-extraction theory are proposed in this paper. Three kinds of graphene-based transmission lines with attenuation phenomenon including microstrip line, double-side parallel strip line, and uniplanar coplanar waveguide are analyzed under the common conditions where different chemical potentials are loaded on graphene. The values of attenuation constant and phase constant, and the real and imaginary parts of the characteristic impedance of transmission lines are extracted to analyze in details. When the attenuation constant and the reactance part of the characteristic impedance are approximately equal to zero, this kind of transmission line has low or zero insertion loss. On the contrary, the transmission line is under the radiation mode with obvious insertion loss. The phase constant changes linearly under the transmission mode and can be varied with changing of chemical potentials which attributes to the property of frequency tunability. Furthermore, a bandwidth reconfigurable uniplanar coplanar waveguide power divider is simulated to demonstrate that this theory can be applied to the design of three-port devices. In summary, this work provides a strong potential approach and design theory to help design other kinds of terahertz and mid-infrared reconfigurable devices.

  12. Propagation behaviour of overhead transmission lines

    African Journals Online (AJOL)

    the physical and electrical characteristics of the lines, their geometric arrangement, height above the ground level and the earth resistivity. 2.1 Admittance matrix. Y is a function only of the physical geometry of conductors relative to the earth plane because the conductor and earth surfaces may each be regarded as ...

  13. Transmission line fault distance and direction estimation using ...

    African Journals Online (AJOL)

    An accurate fault distance and direction estimation based on application of artificial neural networks for protection of doubly fed transmission lines is presented in this paper. The proposed method uses the voltage and current available at only the local end of line. This method is adaptive to the variation of fault location, fault ...

  14. Overhead three-phase transmission lines - Non-diagonalizable situations

    Energy Technology Data Exchange (ETDEWEB)

    Faria, J.A.B. (Centro de Electrotecnia da U.T.L. - Instituto Superior Tecnico, 1096 Lisboa (PT))

    1988-10-01

    Physically realizable transmission lines exist to which the standard modal theory does not apply since the ZY diagonalization cannot always be undertaken successfully. In this paper the non-diagonalizing conditions for typical overhead three-phase lines are established. Algorithms are described and implemented to synthesize concrete non-diagonalizable configurations, numerical examples being presented and discussed.

  15. Stand-off transmission lines and method for making same

    Science.gov (United States)

    Tuckerman, David B.

    1991-01-01

    Standoff transmission lines in an integrated circuit structure are formed by etching away or removing the portion of the dielectric layer separating the microstrip metal lines and the ground plane from the regions that are not under the lines. The microstrip lines can be fabricated by a subtractive process of etching a metal layer, an additive process of direct laser writing fine lines followed by plating up the lines or a subtractive/additive process in which a trench is etched over a nucleation layer and the wire is electrolytically deposited. Microstrip lines supported on freestanding posts of dielectric material surrounded by air gaps are produced. The average dielectric constant between the lines and ground plane is reduced, resulting in higher characteristic impedance, less crosstalk between lines, increased signal propagation velocities, and reduced wafer stress.

  16. Experimental Analysis of Reduced-Sized Coplanar Waveguide Transmission Lines

    Science.gov (United States)

    Ponchak, George E.

    2002-01-01

    An experimental investigation of the use of capacitive loading of coplanar waveguides to reduce their line length and, thus the size, of monolithic microwave integrated circuits is presented. The reduced sized coplanar waveguides are compared to unloaded transmission lines and to lumped element transmission line segments. The phase bandwidth, defined by 2 percent error in S(sub 21), and the return loss bandwidth, defined by a return loss greater than 15 dB, of coplanar waveguides reduced from 0 to 90 percent are compared, and the insertion loss as a function of the size reduction is presented.

  17. ANALYSIS OF CIRCUITS WITH MULTIPLE COUPLED LOSSY TRANSMISSION LINES

    DEFF Research Database (Denmark)

    Dalby, Arne Brejning

    1997-01-01

    The analysis of coupled lossy transmission line structures like microwave directional couplers and filters, 3-phase power cable networks or a databus is not simple. In this paper it is shown that the admittance parameters for the 2N port network, N coupled lossy transmission lines form, may...... be found using a set of almost arbitrary (orthogonal) quasi propagation modes instead of the true modes, if the up-per frequency is so low that the electrical length of the lines is smaller than about 1/3 of the wavelength for the propagation mode with the lowest phase velocity....

  18. Computation of nonuniform transmission lines using the FDTD method

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, G.C.; Paulino, J.O.S. [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil). School of Engineering

    1997-12-31

    Calculation of lightning overvoltages on transmission lines has been described. Lightning induced overvoltages are of great significance under certain conditions because of the main characteristics of the phenomena. The lightning channel model is one of the most important parameters essential to obtaining the generated electromagnetic fields. In this study, nonuniform transmission line equations were solved using the finite difference method and the leap-frog scheme, the Finite Difference Time Domain (FDTD) method. The subroutine was interfaced with the Electromagnetic Transients Program (EMTP). Two models were used to represent the characteristic impedance of the nonuniform lines used to model the transmission line towers and the lightning main channel. The advantages of the FDTD method was the much smaller code and faster processing time. 35 refs., 5 figs.

  19. NOVEL SIGNAL PROCESSING WITH NONLINEAR TRANSMISSION LINES

    Energy Technology Data Exchange (ETDEWEB)

    D. REAGOR; ET AL

    2000-08-01

    Nonlinear dielectrics offer uniquely strong and tunable nonlinearities that make them attractive for current devices (for example, frequency-agile microwave filters) and for future signal-processing technologies. The goal of this project is to understand pulse propagation on nonlinear coplanar waveguide prototype devices. We have performed time-domain and frequency-domain experimental studies of simple waveguide structures and pursued a theoretical understanding of the propagation of signals on these nonlinear waveguides. To realistically assess the potential applications, we used a time-domain measurement and analysis technique developed during this project to perform a broadband electrodynamics characterization in terms of nonlinear, dispersive, and dissipative effects. We completed a comprehensive study of coplanar waveguides made from high-temperature superconducting thin-film YBa{sub 2}Cu{sub 3}O{sub 7{minus}{delta}} electrodes on nonlinear dielectric single-crystal SrTiO{sub 3} substrates. By using parameters determined from small-signal (linear) transmission characteristics of the waveguides, we develop a model equation that successfully predicts and describes large-signal (nonlinear) behavior.

  20. Atlas transmission line/transition design and fabrication status

    CERN Document Server

    Ballard, E O; Davis, H A; Elizondo, J M; Gribble, R F; Nielsen, K E; Parker, G V; Ricketts, R L; Valdez, G A

    1999-01-01

    Atlas is a pulsed-power facility under development at Los Alamos National Laboratory to drive high-energy density experiments. Design has been completed for this new generation pulsed-power machine consisting of an azimuthal array of 24, 240-kV Marx modules and transmission lines supplying current to the load region at the machine center. The transmission line consists of a cable header, load protection switch, and tri-plate assembly interfacing to the center transition section. The cable header interface to the Marx module provides a mechanism to remove the Marx module for maintenance without removing other components of the transmission line. The load protection switch provides a mechanism for protecting the load during charging of the Marx in the event of a pre-fire condition. The aluminum tri-plate is a low-inductance transmission line that carries radial current flow from the Marx energy storage system at the machine periphery toward the load. All transmission line components are oil insulated except the...

  1. Artificial neural network modeling of plasmonic transmission lines.

    Science.gov (United States)

    Andrawis, Robert R; Swillam, Mohamed A; El-Gamal, Mohamed A; Soliman, Ezzeldin A

    2016-04-01

    In this paper, new models based on an artificial neural network (ANN) are developed to predict the propagation characteristics of plasmonic nanostrip and coupled nanostrips transmission lines. The trained ANNs are capable of providing the required propagation characteristics with good accuracy and almost instantaneously. The nonlinear mapping performed by the trained ANNs is written as closed-form expressions, which facilitate the direct use of the results obtained in this research. The propagation characteristics of the investigated transmission lines include the effective refractive index and the characteristic impedance. The time needed to simulate 1000 different versions of the transmission line structure is about 48 h, using a full-wave electromagnetic solver compared to 3 s using the developed ANN model.

  2. Kalman filter estimation of RLC parameters for UMP transmission line

    Directory of Open Access Journals (Sweden)

    Mohd Amin Siti Nur Aishah

    2018-01-01

    Full Text Available This paper present the development of Kalman filter that allows evaluation in the estimation of resistance (R, inductance (L, and capacitance (C values for Universiti Malaysia Pahang (UMP short transmission line. To overcome the weaknesses of existing system such as power losses in the transmission line, Kalman Filter can be a better solution to estimate the parameters. The aim of this paper is to estimate RLC values by using Kalman filter that in the end can increase the system efficiency in UMP. In this research, matlab simulink model is developed to analyse the UMP short transmission line by considering different noise conditions to reprint certain unknown parameters which are difficult to predict. The data is then used for comparison purposes between calculated and estimated values. The results have illustrated that the Kalman Filter estimate accurately the RLC parameters with less error. The comparison of accuracy between Kalman Filter and Least Square method is also presented to evaluate their performances.

  3. Transmission line matrix modelling of thermal injuries to skin.

    Science.gov (United States)

    Aliouat Bellia, S; Saidane, A; Hamou, A; Benzohra, M; Saiter, J M

    2008-08-01

    A numerical model based on the transmission line matrix method is presented for the quantitative prediction of skin burn resulting from exposure of a specific region of human skin surface to a high temperature heat source. Transient temperatures were numerically estimated by Pennes' bioheat equation, and the damage function denoting the extent of burn was calculated using the Arrhenius assumptions for protein damage rate. A two-dimensional transmission line matrix model was used to predict the effects of exposure time and structure thicknesses on the transient temperature distribution and damage extent. Compared with other numerical sources the transmission line matrix results revealed good agreement, suggesting that this method may be an effective tool for the thermal diagnostic of burns.

  4. The fire prevention measures of the underground transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Bang Myung; Tack, Eui Gyun; Kim, Jae Seung [Korea Electric Power Corp. (Korea)

    2001-07-01

    Electric power consumption is highly increasing as the social trend requiring comfortable life, the population in a big city and the industrial development. Therefore is has become to be very important to supply the stable high-quality power. As these trend, the underground power transmission facility is highly increasing in the center of a city. As the proportion to increase facility in tunnel, the fire prevention measures of the underground transmission line become very important. (author). 4 refs., 8 tabs.

  5. Quasi-Optical Transmission Line for 94-GHz Radar

    Science.gov (United States)

    Perez, Raul M.; Veruttipong, Watt

    2008-01-01

    A quasi-optical transmission line (QOTL) has been developed as a low-loss transmission line for a spaceborne cloudobserving radar instrument that operates at a nominal frequency of 94 GHz. This QOTL could also readily be redesigned for use in terrestrial millimeter-wave radar systems and millimeter-wave imaging systems. In the absence of this or another lowloss transmission line, it would be necessary to use a waveguide transmission line in the original radar application. Unfortunately, transmission losses increase and power-handling capacities of waveguides generally decrease with frequency, such that at 94 GHz, the limitation on transmitting power and the combined transmission and reception losses (greater than 5 dB) in a waveguide transmission line previously considered for the original application would be unacceptable. The QOTL functions as a very-lowloss, three-port circulator. The QOTL includes a shaped input mirror that can be rotated to accept 94-GHz transmitter power from either of two high-power amplifiers. Inside the QOTL, the transmitter power takes the form of a linearly polarized beam radiated from a feed horn. This beam propagates through a system of mirrors, each of which refocuses the beam to minimize diffraction losses. A magnetically biased ferrite disc is placed at one of the foci to utilize the Faraday effect to rotate the polarization of the beam by 45 degrees. The beam is then transmitted via an antenna system. The radar return (scatter from clouds, and/or reflections from other objects) is collected by the same antenna and propagates through the Faraday rotator in the reverse of the direction of propagation of the transmitted beam. In the Faraday rotator, the polarization of the received signal is rotated a further 45 degrees, so that upon emerging from the Faraday rotator, the received beam is polarized at 90 with respect to the transmitted beam. The transmitted and received signals are then separated by a wire-grid polarizer.

  6. A Transmission Line Model for the Spherical Beltrami Problem

    Science.gov (United States)

    Papageorgiou, C. D.; Raptis, T. E.

    We extend a previously introduced model for finding eigenvalues and eigenfunctions of PDEs with a certain natural symmetry set based on an analysis of an equivalent transmission line circuit. This was previously applied with success in the case of optical fibers [8], [9] as well as in the case of a linear Schroedinger equation [10], [11] and recently in the case of spherical symmetry (Ball Lightning) [12]. We explore the interpretation of eigenvalues as resonances of the corresponding transmission line model. We use the generic Beltrami problem of non-constant eigen-vorticity in spherical coordinates as a test bed and we locate the bound states and the eigen-vorticity functions.

  7. Reconfigurable Wave Velocity Transmission Lines for Phased Arrays

    Science.gov (United States)

    Host, Nick; Chen, Chi-Chih; Volakis, John L.; Miranda, Felix

    2013-01-01

    Phased array antennas showcase many advantages over mechanically steered systems. However, they are also more complex, heavy and most importantly costly. This presentation paper presents a concept which overcomes these detrimental attributes by eliminating all of the phase array backend (including phase shifters). Instead, a wave velocity reconfigurable transmission line is used in a series fed array arrangement to allow phase shifting with one small (100mil) mechanical motion. Different configurations of the reconfigurable wave velocity transmission line are discussed and simulated and experimental results are presented.

  8. Simulation of stochastic wind action on transmission power lines

    Science.gov (United States)

    Wielgos, Piotr; Lipecki, Tomasz; Flaga, Andrzej

    2018-01-01

    The paper presents FEM analysis of the wind action on overhead transmission power lines. The wind action is based on a stochastic simulation of the wind field in several points of the structure and on the wind tunnel tests on aerodynamic coefficients of the single conductor consisting of three wires. In FEM calculations the section of the transmission power line composed of three spans is considered. Non-linear analysis with deadweight of the structure is performed first to obtain the deformed shape of conductors. Next, time-dependent wind forces are applied to respective points of conductors and non-linear dynamic analysis is carried out.

  9. Self-monitoring high voltage transmission line suspension insulator

    Science.gov (United States)

    Stemler, Gary E.; Scott, Donald N.

    1981-01-01

    A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

  10. Recent techniques used in transmission line protection: A review ...

    African Journals Online (AJOL)

    include almost all the techniques and philosophies of transmission line protection reported in the literature up to October 2010. The focus of this article is on the most recent techniques, like artificial neural network, fuzzy logic, fuzzy-neuro, fuzzy logicwavelet based and phasor measurement unit-based concepts as well as ...

  11. The EC H&CD Transmission Line for ITER

    NARCIS (Netherlands)

    Gandini, F.; Bigelow, T. S.; Becket, B.; Caughman, J. B.; Cox, D.; Darbos, C.; Gassmann, T.; Henderson, M. A.; Jean, O.; Kajiwara, K.; Kobayashi, N.; Nazare, C.; Oda, Y.; Omori, T.; Purohit, D.; Rasmussen, D. A.; Ronden, D. M. S.; Saibene, G.; Sakamoto, K.; Shapiro, M. A.; Takahashi, K.; Temkin, R. J.

    2011-01-01

    The transmission line (TL) subsystem associated with the ITER electron cyclotron heating and current drive system has reached the conceptual design maturity. At this stage the responsibility of finalizing the design has been transferred from the ITER Organization to the U.S. Domestic Agency. The

  12. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    Yomi

    Zeki Demir. Department of Landscape Architecture, Faculty of Forestry, Düzce University. Konuralp, 81620 Düzce, Turkey. E-mail: zekidemir@duzce.edu.tr. Tel: +90-380-5421136. Fax: +90-380-5421136. Accepted 18 August, 2010. The proximity effects of high voltage electric power transmission lines on Leyland Cypress.

  13. Computer-aided Instructional System for Transmission Line Simulation.

    Science.gov (United States)

    Reinhard, Erwin A.; Roth, Charles H., Jr.

    A computer-aided instructional system has been developed which utilizes dynamic computer-controlled graphic displays and which requires student interaction with a computer simulation in an instructional mode. A numerical scheme has been developed for digital simulation of a uniform, distortionless transmission line with resistive terminations and…

  14. Microstrip-Transmission-Line Shock-Front Sensor

    Science.gov (United States)

    Leiweke, Robert J.; Smith, William C.

    1993-01-01

    Microstrip-transmission-line sensor measures velocities of low-overpressure shock fronts and offers dynamic range needed for measurements both far from and near explosions. Fabricated easily, relatively inexpensive, and repaired in field. In addition, basic geometry modified easily, as needed.

  15. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    The proximity effects of high voltage electric power transmission lines on Leyland Cypress (xCupressocyparis leylandii (Dallim. and A.B. Jacks.) Dallim) and Japanese Privet (Ligustrum japonicum Thunb.) growth were examined in a private nursery located in Sakarya, Turkey. Five transect were randomly chosen in both ...

  16. A novel transmission line protection using DOST and SVM

    Directory of Open Access Journals (Sweden)

    M. Jaya Bharata Reddy

    2016-06-01

    Full Text Available This paper proposes a smart fault detection, classification and location (SFDCL methodology for transmission systems with multi-generators using discrete orthogonal Stockwell transform (DOST. The methodology is based on synchronized current measurements from remote telemetry units (RTUs installed at both ends of the transmission line. The energy coefficients extracted from the transient current signals due to occurrence of different types of faults using DOST are being utilized for real-time fault detection and classification. Support vector machine (SVM has been deployed for locating the fault distance using the extracted coefficients. A comparative study is performed for establishing the superiority of SVM over other popular computational intelligence methods, such as adaptive neuro-fuzzy inference system (ANFIS and artificial neural network (ANN, for more precise and reliable estimation of fault distance. The results corroborate the effectiveness of the suggested SFDCL algorithm for real-time transmission line fault detection, classification and localization.

  17. Airplane Ice Detector Based on a Microwave Transmission Line

    Science.gov (United States)

    Ngo, Phong; Arndt, G. Dickey; Carl, James R.

    2004-01-01

    An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a

  18. Theory and Circuit Model for Lossy Coaxial Transmission Line

    Energy Technology Data Exchange (ETDEWEB)

    Genoni, T. C.; Anderson, C. N.; Clark, R. E.; Gansz-Torres, J.; Rose, D. V.; Welch, Dale Robert

    2017-04-01

    The theory of signal propagation in lossy coaxial transmission lines is revisited and new approximate analytic formulas for the line impedance and attenuation are derived. The accuracy of these formulas from DC to 100 GHz is demonstrated by comparison to numerical solutions of the exact field equations. Based on this analysis, a new circuit model is described which accurately reproduces the line response over the entire frequency range. Circuit model calculations are in excellent agreement with the numerical and analytic results, and with finite-difference-time-domain simulations which resolve the skindepths of the conducting walls.

  19. Analytical Model for High Impedance Fault Analysis in Transmission Lines

    Directory of Open Access Journals (Sweden)

    S. Maximov

    2014-01-01

    Full Text Available A high impedance fault (HIF normally occurs when an overhead power line physically breaks and falls to the ground. Such faults are difficult to detect because they often draw small currents which cannot be detected by conventional overcurrent protection. Furthermore, an electric arc accompanies HIFs, resulting in fire hazard, damage to electrical devices, and risk with human life. This paper presents an analytical model to analyze the interaction between the electric arc associated to HIFs and a transmission line. A joint analytical solution to the wave equation for a transmission line and a nonlinear equation for the arc model is presented. The analytical model is validated by means of comparisons between measured and calculated results. Several cases of study are presented which support the foundation and accuracy of the proposed model.

  20. Fast and accurate simulations of transmission-line metamaterials using transmission-matrix method

    OpenAIRE

    Ma, Hui Feng; Cui, Tie Jun; Chin, Jessie Yao; Cheng, Qiang

    2009-01-01

    Recently, two-dimensional (2D) periodically L and C loaded transmission-line (TL) networks have been applied to represent metamaterials. The commercial Agilent's Advanced Design System (ADS) is a commonly-used tool to simulate the TL metamaterials. However, it takes a lot of time to set up the TL network and perform numerical simulations using ADS, making the metamaterial analysis inefficient, especially for large-scale TL networks. In this paper, we propose transmission-matrix method (TMM) t...

  1. Sensor Placement For Structural Monitoring of Transmission Line Towers

    Directory of Open Access Journals (Sweden)

    Benny eRaphael

    2015-11-01

    Full Text Available Transmission line towers are usually analyzed using linear elastic idealized truss models. Due to the assumptions used in the analysis, there are discrepancies between the actual results obtained from full scale prototype testing and the analytical results. Therefore, design engineers are interested in assessing the actual stress levels in transmission line towers. Since it is costly to place sensors on every member of a tower structure, the best locations for sensors need to be carefully selected. This study evaluates a methodology for sensor placement in transmission line towers. The objective is to find optimal locations for sensors such that the real behavior of the structure can be explained from measurements. The methodology is based on the concepts of entropy and model falsification. Sensor locations are selected based on maximum entropy such that there is maximum separation between model instances that represent different possible combinations of parameter values which have uncertainties. The performance of the proposed algorithm is compared to that of an intuitive method in which sensor locations are selected where the forces are maximum. A typical 220 kV transmission tower is taken as case study in this paper. It is shown that the intuitive method results in much higher number of non-separable models compared to the optimal sensor placement algorithm. Thus the intuitive method results in poor identification of the system.

  2. Wireless Sensor Network for Electric Transmission Line Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Alphenaar, Bruce

    2009-06-30

    Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and cost effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications

  3. Insulation design for KEPCO 765 kV Transmission Lines

    Energy Technology Data Exchange (ETDEWEB)

    Koo, B. M.; Won, Y. J.; Hwang, J. I. [KEPCO (Korea, Republic of)

    1994-07-01

    KEPCO is new promoting the new project of upgrading its highest system voltage from 345 kV to 765 kV. The main reason of this project is an insurance of bulk power transmission from power complexes at coast to power demand center at Kyoung-In area. The new system needs a careful approach to basic design to secure its reliability and to reduce the increase of investment cost. So, We introduced the basic philosophy of insulation design in spring meeting of this transaction. This paper, after preceding paper, deals with the insulation design example for 765 kV transmission lines. (author). 12 refs., 5 figs., 11 tabs.

  4. 76 FR 14986 - Notice of Availability of the Record of Decision for the One Nevada Transmission Line (ON Line...

    Science.gov (United States)

    2011-03-18

    ... Transmission Line (ON Line) Project. Lands described in the ROW authorizations are located within the BLM Ely... facilities described in the Proposed Action, including the transmission-line route, except the R-SS-Site B... 4500019905; TAS: 14X5017] Notice of Availability of the Record of Decision for the One Nevada Transmission...

  5. Transmission Delay Modeling of Packet Communication over Digital Subscriber Line

    Directory of Open Access Journals (Sweden)

    Jiri Vodrazka

    2013-01-01

    Full Text Available Certain multimedia and voice services, such as VoIP, IPTV, etc., are significantly delay sensitive and their performance is influenced by the overall transmission delay and its variance. One of the most common solutions used in access networks are xDSL lines, especially ADSL2+ or VDSL2. Although these subscriber lines also use packet communication, there are several differences and mechanisms, which influence their resulting delay. Their delay characteristics are also dependent on the individual settings of each xDSL provider, therefore we decided to investigate this area for typical commercially available lines in Czech Republic. Based on the measured values and experiments with real ADSL2+ lines we also developed a potential modeling method, which is presented in this article as well. The parameters for packet jitter based on the generalized Pareto distribution were modeled.

  6. Homoclinic bifurcations in a neutral delay model of a transmission line oscillator

    NARCIS (Netherlands)

    Barton, D.A.W.; Krauskopf, B.; Wilson, R.E.

    2007-01-01

    In a transmission line oscillator (TLO) a linear wave travels along a piece of cable, the transmission line, and interacts with terminating electrical components. A fixed time delay arises due to the transmission time through the transmission line. Recent experiments on a TLO driven by a negative

  7. 7 CFR 1726.76 - Substation and transmission line materials and equipment.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Substation and transmission line materials and... Substation and Transmission Facilities § 1726.76 Substation and transmission line materials and equipment. (a... $500,000 and for all materials. (b) Standards and specifications. Substation and transmission line...

  8. HTS DC Transmission Line for Megalopolis Grid Development

    Science.gov (United States)

    Kopylov, S.; Sytnikov, V.; Bemert, S.; Ivanov, Yu; Krivetskiy, I.; Romashov, M.; Shakaryan, Yu; Keilin, V.; Shikov, A.; Patrikeev, V.; Lobyntsev, V.; Shcherbakov, V.

    2014-05-01

    Using of HTS AC and DC cables in electric power grids allows increasing of the transferred power, losses diminishing, decreasing of exclusion zone areas, the enhancement of the environmental conditions and fire/explosion safety of electric power systems. However, the use of DC superconducting cable lines together with converters brings additional advantages as reduction of losses in cables and suitable lowering of refrigerating plant capacity, as well as the realization of the function of short-circuit currents limitation by means of the appropriate setting of converter equipment. Russian Federal Grid Company and its R&D Center started the construction of the DC HTS power transmission line which includes the cable itself, cryogenic equipment, AC/DC converters, terminals and cable coupling boxes. This line will connect two substations in Saint-Petersburg - 330 kV "Centralnaya" and 220 kV "RP-9". The length of this HTS transmission line will be about 2500 meters. Nowadays are developed all the elements of the line and technologies of the cable manufacturing. Two HTS cable samples, each 30 m length, have been made. This paper describes the results of cables tests.

  9. Perfect Thermal Emission by Nanoscale Transmission Line Resonators.

    Science.gov (United States)

    Liu, Baoan; Gong, Wei; Yu, Bowen; Li, Pengfei; Shen, Sheng

    2017-02-08

    Thermal radiation with a narrow-band emission spectrum is of great importance in a variety of applications such as infrared sensing, thermophotovoltaics, radiation cooling, and thermal circuits. Although resonant nanophotonic structures such as metamaterials and nanocavities have been demonstrated to achieve the narrow-band thermal emission, maximizing their radiation power toward perfect emission still remains challenging. Here, based on the recently developed quasi-normal mode theory, we prove that thermal emission from a nanoscale transmission line resonator can always be maximized by tuning the waveguiding loss of the resonator or bending the structure. By use of nanoscale transmission line resonators as basic building blocks, we experimentally demonstrate a new type of macroscopic perfect and tunable thermal emitters. Our experimental demonstration in conjunction with the general theoretical framework from the quasi-normal mode theory lays the foundation for designing tunable narrow-band thermal emitters with applications in thermal infrared light sources, thermal management, and infrared sensing and imaging.

  10. Comparison of Transmission Line Methods for Surface Acoustic Wave Modeling

    Science.gov (United States)

    Wilson, William; Atkinson, Gary

    2009-01-01

    Surface Acoustic Wave (SAW) technology is low cost, rugged, lightweight, extremely low power and can be used to develop passive wireless sensors. For these reasons, NASA is investigating the use of SAW technology for Integrated Vehicle Health Monitoring (IVHM) of aerospace structures. To facilitate rapid prototyping of passive SAW sensors for aerospace applications, SAW models have been developed. This paper reports on the comparison of three methods of modeling SAWs. The three models are the Impulse Response Method (a first order model), and two second order matrix methods; the conventional matrix approach, and a modified matrix approach that is extended to include internal finger reflections. The second order models are based upon matrices that were originally developed for analyzing microwave circuits using transmission line theory. Results from the models are presented with measured data from devices. Keywords: Surface Acoustic Wave, SAW, transmission line models, Impulse Response Method.

  11. Reconfigurable Wave Velocity Transmission Lines for Phased Arrays

    Science.gov (United States)

    Host, Nicholas Keith; Chen, Chi-Chih; Volakis, John L.

    2012-01-01

    This presentation discussed a novel phased array with an emphasis to simplify the array feed. Specifically, we will demonstrate a simple, low cost feeding approach by mechanically controlling the substrate thickness. The array feed lines are constructed from parallel plate transmission lines whose thickness are adjusted to control their effective dielectric constant (Epsilon_eff). As a result the phase delay/excitation at each array element will be adjusted per desired beam direction. The proposed antenna elements will be overlapping dipoles operating over a 2:1 bandwidth in the Ku-Band spectrum. Preliminary simulation and experimental demonstration of such an array will be presented.

  12. Signal encoding for party-line digital data transmission

    CERN Document Server

    Taylor, B G

    1975-01-01

    A digital encoding method is described which permits a single clock generator to synchronise data transmission on a party-line busbar shared by many transceivers. The requirements for either a separate busbar for clock distribution or individual clocks in each transceiver are eliminated by the use of a signal set which allows the busbar to carry data and synchronising information generated simultaneously by separate sources. (10 refs).

  13. Superluminal tunneling of microwaves in smoothly varying transmission lines.

    Science.gov (United States)

    Shvartsburg, A B; Marklund, M; Brodin, G; Stenflo, L

    2008-07-01

    Tunneling of microwaves through a smooth barrier in a transmission line is considered. In contrast to standard wave barriers, we study the case where the dielectric permittivity is positive, and the barrier is caused by the inhomogeneous dielectric profile. It is found that reflectionless, superluminal tunneling can take place for waves with a finite spectral width. The consequences of these findings are discussed, and an experimental setup testing our predictions is proposed.

  14. Transmission lines protection based on the current eigenvalues differential concept

    OpenAIRE

    Pires, V. Fernão; Guerreiro, M.; Fortunato, Carlos; Martins, L. Sousa

    2010-01-01

    This work presents a new approach for a current differential protection of the transmission lines. The proposed approach is based on the Clarke-Concordia transformation and principal component analysis. First the acquired current signals are transformed into “αβo” components by applying the Clarke-Concordia transformation. This allows obtaining typical patterns. To identify these patterns a principal component analysis is performed. Several tests under different fault conditions were performe...

  15. Generation Level Matching to the Transmission Capability of Overhead Lines

    Directory of Open Access Journals (Sweden)

    Piotr Kacejko

    2013-03-01

    Full Text Available The article presents a new algorithm for real-time current overload clearance in power lines. It combines an optimization method with a method of load flow tracing, which may seem a little futuristic, but it enables effective clearance of the effects of exceeded allowed transmission capability. The algorithm is meant for cyclical determination of such an allowed instantaneous value of generated power in each wind farm that makes possible to clear the overload having all the grid constraints satisfied.

  16. Generation Level Matching to the Transmission Capability of Overhead Lines

    OpenAIRE

    Piotr Kacejko; Paweł Pijarski

    2013-01-01

    The article presents a new algorithm for real-time current overload clearance in power lines. It combines an optimization method with a method of load flow tracing, which may seem a little futuristic, but it enables effective clearance of the effects of exceeded allowed transmission capability. The algorithm is meant for cyclical determination of such an allowed instantaneous value of generated power in each wind farm that makes possible to clear the overload having all the grid constraints s...

  17. An explicit method for modeling lossy and dispersive transmission lines

    OpenAIRE

    Palà Schönwälder, Pere; Miró Sans, Joan Maria

    1993-01-01

    In this paper, an explicit -non iterative- method for modeling lossy and dispersive transmission lines, allowing the inclusion of skin-effect parameters is described. This method, based on multipoint Padé approximation, allows direct implementation to obtain models for existing simulation program -such as SPICE-without the need of making use of optimization algorithms at any stage. Examples are given to show that the described procedure yields the same accuracy as other existing techniques th...

  18. Gas insulated transmission line with insulators having field controlling recesses

    Science.gov (United States)

    Cookson, Alan H.; Pederson, Bjorn O.

    1984-01-01

    A gas insulated transmission line having a novel insulator for supporting an inner conductor concentrically within an outer sheath. The insulator has a recess contiguous with the periphery of one of the outer and inner conductors. The recess is disposed to a depth equal to an optimum gap for the dielectric insulating fluid used for the high voltage insulation or alternately disposed to a large depth so as to reduce the field at the critical conductor/insulator interface.

  19. Lambing behaviour of Merino ewes from lines subjected to divergent ...

    African Journals Online (AJOL)

    Lambing behaviour of Merino ewes from lines subjected to divergent selection for multiple rearing ability from the same base population. ... likely than those in the H line to graze. The latter group of ewes was more likely to stand with their offspring at this stage. South African Journal of Animal Science Vol.32(1) 2002: 57-65 ...

  20. Sound transmission of cavity walls due to structure borne transmission via point and line connections.

    Science.gov (United States)

    Davy, John L

    2012-08-01

    The author has published equations for predicting the air borne sound transmission of double leaf cavity walls due to the structure borne sound transmission across the air cavity via (possibly resilient) line connections, but has never published the full derivation of these equations. The author also derived equations for the case when the connections are rigid point connections but has never used them or published them or their derivations. This paper will present the full derivation of the author's theory of the air borne sound transmission of double leaf cavity walls due to the structure borne sound transmission across the air cavity via point or line connections which are modeled as four pole networks. The theoretical results will be compared with experimental results on wooden stud cavity walls from the National Research Council of Canada because the screw spacing is given for these results. This enables connections via studs and screws to be modeled as point connections and avoids the need to make any assumptions about the compliance of the equivalent point or line connections.

  1. Chameleon's behavior of modulable nonlinear electrical transmission line

    Science.gov (United States)

    Togueu Motcheyo, A. B.; Tchinang Tchameu, J. D.; Fewo, S. I.; Tchawoua, C.; Kofane, T. C.

    2017-12-01

    We show that modulable discrete nonlinear transmission line can adopt Chameleon's behavior due to the fact that, without changing its appearance structure, it can become alternatively purely right or left handed line which is different to the composite one. Using a quasidiscrete approximation, we derive a nonlinear Schrödinger equation, that predicts accurately the carrier frequency threshold from the linear analysis. It appears that the increasing of the linear capacitor in parallel in the series branch induced the selectivity of the filter in the right-handed region while it increases band pass filter in the left-handed region. Numerical simulations of the nonlinear model confirm the forward wave in the right handed line and the backward wave in the left handed one.

  2. Development of Live-working Robot for Power Transmission Lines

    Science.gov (United States)

    Yan, Yu; Liu, Xiaqing; Ren, Chengxian; Li, Jinliang; Li, Hui

    2017-07-01

    Dream-I, the first reconfigurable live-working robot for power transmission lines successfully developed in China, has the functions of autonomous walking on lines and accurately positioning. This paper firstly described operation task and object of the robot; then designed a general platform, an insulator replacement end and a drainage plate bolt fastening end of the robot, presented a control system of the robot, and performed simulation analysis on operation plan of the robot; and finally completed electrical field withstand voltage tests in a high voltage hall as well as online test and trial on actual lines. Experimental results show that by replacing ends of manipulators, the robot can fulfill operation tasks of live replacement of suspension insulators and live drainage plate bolt fastening.

  3. Cyber Risk Assessment of Transmission Lines in Smart Grids

    Directory of Open Access Journals (Sweden)

    Xuan Liu

    2015-12-01

    Full Text Available The increasing use of information technologies in power systems has increased the risk of power systems to cyber-attacks. In this paper, we assess the risk of transmission lines being overloaded due to cyber-based false data injection attacks. The cyber risk assessment is formulated as bilevel optimization problems that determine the maximum line flows under false data injection attacks. We propose efficient techniques to reduce the computation complexity of solving the bilevel problems. Specifically, primary and secondary filtering techniques are employed to identify the lines whose flows will never exceed their limits, which can significantly reduce computation burden. A special feasibility cut-based acceleration technique is introduced to further reduce the computation burden. The simulation results on the IEEE 30-bus, IEEE 118-bus, IEEE 300-bus and IEEE 2383-bus systems verify the proposed risk assessment model and the effectiveness of the proposed filtering and acceleration techniques.

  4. Optimal Placement of Unified Power Flow Controllers : An Approach to Maximize the Loadability of Transmission Lines

    Directory of Open Access Journals (Sweden)

    S. T. Jaya Christa

    2006-06-01

    Full Text Available This paper deals with the optimal location and parameters of Unified Power Flow Controllers (UPFCs in electrical power systems, using particle swarm optimization (PSO. The objective is to maximize the transmission system loadability subject to the transmission line capacity limits and specified bus voltage levels. Using the proposed method, the location of UPFCs and their parameters are optimized simultaneously. PSO is used to solve the above non-linear programming problem for better accuracy. The proposed approach is examined and tested on IEEE 30-bus system and IEEE 118-bus system. The results obtained are quite promising for the power system operation environment

  5. Pulse sharpening effects of thin film ferroelectric transmission lines

    Science.gov (United States)

    Sleezer, Robert J.

    Advances in material science have resulted in the development of electrically nonlinear high dielectric thin film ferroelectrics, which have led to new opportunities for the creation of novel devices. This dissertation investigated one such device: a low voltage nonlinear transmission line (NLTL). A finite element simulation of ferroelectric transmission lines showed that NLTLs are capable of creating shockwaves. Additionally, if the losses are kept sufficiently low, it was shown that voltage gain should be possible. Furthermore, a method of accounting for material dispersion was developed. Results from simulations including material dispersion showed that temporal solitons might be possible from a continuous ferroelectric based nonlinear transmission line. Fabrication of a thin film ferroelectric NLTL required the growth of a ferroelectric material on a conductive substrate. Barium titanate (BTO), which has been gaining popularity due to its high dielectric constant, strong nonlinearity, and lack of lead, was grown. Molecular beam epitaxy and sol-gel growth were both explored and sol-gel was chosen as the growth method for the final device, in part due to its ability to grow BTO thin films on highly conductive nickel substrates. Samples approximately 330 nm thick were grown by this method. Oxygen vacancies in the as grown BTO films were filled by annealing in low pressure oxygen environments. X-ray diffraction measurements were used to determine an O2 pressure for oxidation that was slightly less than the pressure at which NiO forms to ensure maximum filling of the vacancies in the BTO. Grown samples were successfully shown to have ferroelectric properties. A lumped element transmission line was fabricated using discrete capacitors and inductors with a sample as described above. Test capacitors were fabricated and used to determine the dielectric constant of the BTO thin film. This was used to select capacitor pad sizes and inductor values to create a 50 Ohm line

  6. Study on Seismic Control of Power Transmission Tower-Line Coupled System under Multicomponent Excitations

    Directory of Open Access Journals (Sweden)

    Li Tian

    2013-01-01

    Full Text Available The seismic control of power transmission tower-line coupled system subjected to multicomponent excitations is studied in this paper. The schematic of tuned mass damper is introduced, and equations of motion of a system with tuned mass damper under multi-component excitations are proposed. Three-dimensional finite tower-line system models are created based on practical engineering in studying the response of this system without and with control. The time domain analysis takes into account geometric nonlinearity due to finite deformation. The optimal design of the transmission tower-line system with tuned mass damper is obtained according to different mass ratio. The effects of wave travel, coherency loss, and different site conditions on the system without and with control are investigated, respectively.

  7. Study on Tower Models for EHV Transmission Line

    Directory of Open Access Journals (Sweden)

    Xu Bao-Qing

    2016-01-01

    Full Text Available Lightning outage accident is one of the main factors that threat seriously the safe and reliable operation of power system. So it is very important to establish reasonable transmission tower model and evaluate the impulse response characteristic of lightning wave traveling on the transmission tower properly for determining reliable lightning protection performance. With the help of Electromagnetic Transient Program (EMTP, six 500kV tower models are built. Aiming at one line to one transformer operating mode of 500kV substation, the intruding wave overvoltage under different tower models is calculated. The effect of tower model on intruding overvoltage has been studied. The results show that different tower models can result in great differences to the calculation results. Hence, reasonable selection of the tower model in the calculation of back- strike intruding wave is very important.

  8. 75 FR 19963 - Florida Gas Transmission Company, LLC; Transcontinental Gas Pipe Line Company, LLC; Florida Gas...

    Science.gov (United States)

    2010-04-16

    ... Energy Regulatory Commission Florida Gas Transmission Company, LLC; Transcontinental Gas Pipe Line Company, LLC; Florida Gas Transmission Company, LLC; Notice of Availability of the Environmental... Florida Gas Transmission Company, LLC (FGT) and the Pascagoula Expansion Project proposed by FGT and...

  9. Improved Field Homogeneity for Transmission Line MRI Coils Using Series Capacitors

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Dong, Yunfeng

    2015-01-01

    High field magnetic resonance imaging (MRI) systems often use short sections of transmission lines for generating and sensing alternating magnetic fields. Due to distributed nature of transmission lines, the generated field is inhomogeneous. This work investigates the application of series...

  10. Research on Line Patrol Strategy of 110kV Transmission Line after Lightning Strike

    Directory of Open Access Journals (Sweden)

    Li Mingjun

    2016-01-01

    Full Text Available Lightning faults occupy in the majority of instantaneous fault and reclosing can usually be successful, so power supply can be restored without immediate patrol in many cases. Firstly, this paper introduces the lightning fault positioning and identifying method. Then test electrical performance of insulators after lightning strike from 110kV lines. Data shows that lightning strike has little effect on the electric performance of insulator. Finally, illustrating disposal process of the 110 kV transmission line after lightning fault, certifying that the power supply reliability be ensured without line patrol.

  11. Theoretical Analysis of Tuned HVAC Line for Low Loss Long Distance Bulk Power Transmission

    OpenAIRE

    Ukil, Abhisek

    2015-01-01

    One of the main objectives of the smart grid initiative is to enable bulk power transmission over long distance, with reduced transmission losses. Besides the traditional high-voltage alternating current (HVAC) transmission, with the advancement in power electronics, high-voltage direct current (HVDC) transmission is increasingly becoming important. One of the main factors impacting the transmission line parameters and the losses is the length of the transmission line (overhead). In this pape...

  12. LineCast: line-based distributed coding and transmission for broadcasting satellite images.

    Science.gov (United States)

    Wu, Feng; Peng, Xiulian; Xu, Jizheng

    2014-03-01

    In this paper, we propose a novel coding and transmission scheme, called LineCast, for broadcasting satellite images to a large number of receivers. The proposed LineCast matches perfectly with the line scanning cameras that are widely adopted in orbit satellites to capture high-resolution images. On the sender side, each captured line is immediately compressed by a transform-domain scalar modulo quantization. Without syndrome coding, the transmission power is directly allocated to quantized coefficients by scaling the coefficients according to their distributions. Finally, the scaled coefficients are transmitted over a dense constellation. This line-based distributed scheme features low delay, low memory cost, and low complexity. On the receiver side, our proposed line-based prediction is used to generate side information from previously decoded lines, which fully utilizes the correlation among lines. The quantized coefficients are decoded by the linear least square estimator from the received data. The image line is then reconstructed by the scalar modulo dequantization using the generated side information. Since there is neither syndrome coding nor channel coding, the proposed LineCast can make a large number of receivers reach the qualities matching their channel conditions. Our theoretical analysis shows that the proposed LineCast can achieve Shannon's optimum performance by using a high-dimensional modulo-lattice quantization. Experiments on satellite images demonstrate that it achieves up to 1.9-dB gain over the state-of-the-art 2D broadcasting scheme and a gain of more than 5 dB over JPEG 2000 with forward error correction.

  13. Novel transmission lines for the submillimeter-wave region

    Science.gov (United States)

    Katehi, Linda P. B.

    1992-01-01

    Accounts are given of the two approaches to the design of low-loss sub-mm-wave transmission lines for intelligent computer control guidance, command systems for space applications, and sensors operating in an optically opaque environment. These are: (1) the extension of the mm-wave monolithic technology to higher frequencies, although this approach is restricted to the lower end of the sub-mm spectrum, up to 500 GHz, due to ohmic losses; and (2) the extension of optical techniques to lower frequencies. This second approach is also limited, to the higher end of the sub-mm spectrum. Available characterizations of these technologies' electrical properties are presented.

  14. Modeling of planar quasi-TEM superconducting transmission lines

    Science.gov (United States)

    Antsos, Dimitrios; Chew, Wilbert; Riley, A. L.; Hunt, Brian D.; Foote, Marc C.; Bajuk, Louis J.; Rascoe, Daniel L.; Cooley, Thomas W.

    1992-01-01

    An application of the phenomenological loss equivalence method (Lee and Itoh, 1989) in modeling the microwave behavior of planar quasi-TEM superconducting transmission lines is presented. For validation of the model, data are used from measurements of a YBCO superconducting thin-film coplanar-waveguide lowpass filter on a lanthanum aluminate substrate. Measured and modeled S-parameters of an existing superconducting coplanar waveguide lowpass filter agree to within 0.3 dB in magnitude and 0.5 radians in phase. Extracted values for penetration depth and real part of the conductivity of the superconducting film are within 10 percent of other researchers' findings.

  15. Time-dependent sources identification for transmission lines problems

    Directory of Open Access Journals (Sweden)

    J. Benoit

    2015-10-01

    Full Text Available This paper is devoted to introduce an extension to the Linear Combination of Configuration Fields (LCCF. This new numerical method was designed to compute the time profile of an electromagnetic source radiating a specified electromagnetic field in all or part of the computational domain, for a specified duration. Here, we extend this idea within the framework of a transmission lines network. The principle of the method is first validated numerically. Then we prospect the same ideas in a real-data experiment which shows that the method is ready for real-life investigations.

  16. Walking Posture Control of Transmission Line Single Arm Inspection Robot

    Science.gov (United States)

    Yan, Yu; Liu, Xiaqing; Li, Jinliang; Ou, Yuexiong

    2017-07-01

    To control the walking posture according to transmission line single arm inspection robot, the robot is divided into normal walking and climbing walking two state, and gives the definition, then based on the state space method of state variable feedback and PD control method is used to control the two states, two kinds of control method of simulation by using Matlab, in the end, the two control methods proposed is validated in the actual circuit structures. The results show that, the proposed control method is rapid and effective, and can meet the needs of practical application.

  17. Achieving broadband electromagnetic transparency with transmission line metamaterials

    Science.gov (United States)

    Li, Tinghua; Huang, Ming; Yang, Jingjing; Xu, Xingui; Chen, Min

    2015-04-01

    Electromagnetic transparent device (ETD) capable of protecting the device inside without affecting its performance is a fascinating device with extensive application prospects. In this paper, an equivalent circuit method for realizing ETD using transmission line (TL) metamaterials is presented. The validity of such a method and the transparent effect of the device are demonstrated through the Agilent's Advanced Design System (ADS) circuit simulator. Moreover, the influence of the quality factor of lumped elements on the performance of the device and its broadband characteristics are also investigated. This work suggests an alternative way to achieve the broadband electromagnetic transparency and has great guiding significance for the practical fabrication of ETD.

  18. 76 FR 21338 - Reopening of Scoping Period for the Northern Pass Transmission Line Project Environmental Impact...

    Science.gov (United States)

    2011-04-15

    ... Reopening of Scoping Period for the Northern Pass Transmission Line Project Environmental Impact Statement... (DOE) is reopening the public scoping period for the Northern Pass Transmission Line Project... construct, operate, maintain, and connect a new electric transmission line across the U.S.-Canada border in...

  19. 76 FR 26183 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Science.gov (United States)

    2011-05-06

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; Repair of High Voltage Transmission Lines... transmission lines to Logan Airport. This safety zone is required to provide for the safety of life on navigable waters during the repair of high voltage transmission lines. Entering into, transiting through...

  20. 76 FR 34969 - Extension of Scoping Period for the Northern Pass Transmission Line Project Environmental Impact...

    Science.gov (United States)

    2011-06-15

    ... Extension of Scoping Period for the Northern Pass Transmission Line Project Environmental Impact Statement... (DOE) is reopening the public scoping period for the Northern Pass Transmission Line Project..., operate, maintain, and connect a new electric transmission line across the U.S.-Canada border in northern...

  1. 76 FR 15970 - Central Ferry to Lower Monumental 500-kilovolt Transmission Line Project

    Science.gov (United States)

    2011-03-22

    ... Bonneville Power Administration Central Ferry to Lower Monumental 500-kilovolt Transmission Line Project... the Central Ferry--Lower Monumental 500-kilovolt (kV) Transmission Line Project in Garfield, Columbia... identified in the Central Ferry--Lower Monumental 500-kV Transmission Line Project Final Environmental Impact...

  2. 78 FR 57372 - Northern Pass Transmission Line Project Environmental Impact Statement: Announcement of Change in...

    Science.gov (United States)

    2013-09-18

    ... Northern Pass Transmission Line Project Environmental Impact Statement: Announcement of Change in Public... amended Notice of Intent (NOI) to modify the scope of the Northern Pass Transmission Line Project... information on the Northern Pass Transmission Line Project EIS is available on the EIS Web site at http://www...

  3. 76 FR 72001 - Draft Environmental Impact Statement for the Susquehanna to Roseland 500-kilovolt Transmission Line

    Science.gov (United States)

    2011-11-21

    ... Transmission Line AGENCY: National Park Service, Interior. ACTION: Notice of Availability. SUMMARY: The... Susquehanna to Roseland 500-kilovolt transmission line, which will affect the Appalachian National Scenic... visitors each year. The existing transmission line right-of-way predates the establishment of the...

  4. 75 FR 56051 - Bemidji to Grand Rapids Minnesota 230 kV Transmission Line Project

    Science.gov (United States)

    2010-09-15

    ...; ] DEPARTMENT OF AGRICULTURE Rural Utilities Service Bemidji to Grand Rapids Minnesota 230 kV Transmission Line... Rapids, Minnesota 230 kV Transmission Line Project (``Project'') in Minnesota. The Final EIS was prepared...) transmission line between the Wilton Substation near Bemidji, Minnesota and the Boswell Substation near Grand...

  5. 76 FR 19698 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Science.gov (United States)

    2011-04-08

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; Repair of High Voltage Transmission Lines..., within the Captain of the Port (COTP) Boston Zone to allow for repair of high voltage transmission lines... during the repair of high voltage transmission lines. Entering into, transiting through, mooring or...

  6. 76 FR 4575 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Science.gov (United States)

    2011-01-26

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AAOO Safety Zone; Repair of High Voltage Transmission Lines... of high voltage transmission lines to Logan Airport. This safety zone is required to provide for the safety of life on navigable waters during the repair of high voltage transmission lines. Entering into...

  7. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be bound...

  8. 49 CFR 192.713 - Transmission lines: Permanent field repair of imperfections and damages.

    Science.gov (United States)

    2010-10-01

    ... Maintenance § 192.713 Transmission lines: Permanent field repair of imperfections and damages. (a) Each imperfection or damage that impairs the serviceability of pipe in a steel transmission line operating at or... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Permanent field repair of...

  9. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Permanent field repair of... § 192.717 Transmission lines: Permanent field repair of leaks. Each permanent field repair of a leak on a transmission line must be made by— (a) Removing the leak by cutting out and replacing a...

  10. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Permanent field repair of... § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable under § 192.241(c) must be repaired as follows: (a) If it is feasible to take the segment of transmission line...

  11. 49 CFR 192.711 - Transmission lines: General requirements for repair procedures.

    Science.gov (United States)

    2010-10-01

    ... Maintenance § 192.711 Transmission lines: General requirements for repair procedures. (a) Temporary repairs... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: General requirements for..., imperfection, or damage that impairs its serviceability is found in a segment of steel transmission line...

  12. Germline transmission of a novel rat embryonic stem cell line derived from transgenic rats.

    Science.gov (United States)

    Men, Hongsheng; Bauer, Beth A; Bryda, Elizabeth C

    2012-09-20

    Germline-competent rat embryonic stem (ES) cell lines are important resources for the creation of mutant rat models using ES-cell-based gene targeting technology. The ability to isolate germline-competent ES cell lines from any rat strain, including genetically modified strains, would allow for more sophisticated genetic manipulations without extensive breeding. Sprague Dawley (SD) males carrying an enhanced green fluorescent protein (EGFP) transgene were used as the founder animals for the derivation of ES cell lines. A number of ES cell lines were established and subjected to rigorous quality control testing that included assessment of pluripotency factor expression, karyotype analysis, and pathogen/sterility testing. Two male ES cell lines, SD-Tg.EC1/Rrrc and SD-Tg.EC8/Rrrc, were injected into blastocysts recovered from a cross of Dark Agouti (DA) males with SD females. Resulting chimeric animals were bred with wild-type SD mates to verify the germline transmissibility of the ES cell lines by identifying pups carrying the ES cell line-derived EGFP transgene. While both ES cell lines gave rise to chimeric animals, only SD-Tg.EC1 was germline competent. This confirms the feasibility of deriving germline-competent ES cell lines from transgenic rat strains and provides a novel ES cell line with a stable green fluorescent protein (GFP) reporter for future genetic manipulations to create new rat models.

  13. Material selection of a ferrimagnetic loaded coaxial delay line for phasing gyromagnetic nonlinear transmission lines.

    Science.gov (United States)

    Johnson, J M; Reale, D V; Cravey, W H; Garcia, R S; Barnett, D H; Neuber, A A; Dickens, J C; Mankowski, J J

    2015-08-01

    Implementing nonlinear transmission line (NLTL) technology in the design of a high power microwave source has the benefits of producing a comparatively small and lightweight solid-state system where the emission frequency is easily tuned. Usually, smaller in physical size, single NLTLs may produce significantly less power than its vacuum based counterparts. However, combining individual NLTL outputs electrically or in free-space is an attractive solution to achieve greater output power. This paper discusses a method for aligning a four element NLTL antenna array with coaxial geometry using easily adjustable temporal delay lines. These delay lines, sometimes referred to as pulse shock lines or pulse sharpening lines, are placed serially in front of the main NLTL line. The propagation velocity in each delay line is set by the voltage amplitude of an incident pulse as well as the magnetic field bias. Each is adjustable although for the system described in this paper, the voltage is held constant while the bias is changed through applying an external DC magnetic field of varying magnitude. Three different ferrimagnetic materials are placed in the temporal delay line to evaluate which yields the greatest range of electrical delay with the least amount of variability from consecutive shots.

  14. Smaller-loss planar SPP transmission line than conventional microstrip in microwave frequencies.

    Science.gov (United States)

    Zhang, Hao Chi; Zhang, Qian; Liu, Jun Feng; Tang, Wenxuan; Fan, Yifeng; Cui, Tie Jun

    2016-03-17

    Transmission line is a basic component in all passive devices, integrated circuits, and systems. Microstrip is the most popular transmission line in the microwave and millimeter-wave frequencies, and has been widely used in current electronic devices, circuits, and systems. One of the important issues to be solved in such applications is the relatively large transmission loss of microstrip. Here, we propose a method to reduce the loss of microwave transmission line based on the designable wavenumber of spoof surface plasmon polaritons (SPPs). Using this characteristic, we analyze and experimentally demonstrate the low-loss feature of the SPP transmission line through the perturbation method and S-parameter measurements, respectively. Both simulation and experimental results show that the SPP transmission line has much smaller transmission loss than traditional microstrip with the same size in the microwave frequencies. Hence, the spoof SPP transmission line may make a big step forward in the low-loss circuits and systems.

  15. Fuzzy logic based on-line fault detection and classification in transmission line.

    Science.gov (United States)

    Adhikari, Shuma; Sinha, Nidul; Dorendrajit, Thingam

    2016-01-01

    This study presents fuzzy logic based online fault detection and classification of transmission line using Programmable Automation and Control technology based National Instrument Compact Reconfigurable i/o (CRIO) devices. The LabVIEW software combined with CRIO can perform real time data acquisition of transmission line. When fault occurs in the system current waveforms are distorted due to transients and their pattern changes according to the type of fault in the system. The three phase alternating current, zero sequence and positive sequence current data generated by LabVIEW through CRIO-9067 are processed directly for relaying. The result shows that proposed technique is capable of right tripping action and classification of type of fault at high speed therefore can be employed in practical application.

  16. Wild Horse 69-kV transmission line environmental assessment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    Hill County Electric Cooperative Inc. (Hill County) proposes to construct and operate a 69-kV transmission line from its North Gildford Substation in Montana north to the Canadian border. A vicinity project area map is enclosed as a figure. TransCanada Power Corporation (TCP), a Canadian power-marketing company, will own and construct the connecting 69-kV line from the international border to Express Pipeline`s pump station at Wild Horse, Alberta. This Environmental Assessment is prepared for the Department of Energy (DOE) as lead federal agency to comply with the requirements of the National Environmental Policy Act (NEPA), as part of DOE`s review and approval process of the applications filed by Hill County for a DOE Presidential Permit and License to Export Electricity to a foreign country. The purpose of the proposed line is to supply electric energy to a crude oil pump station in Canada, owned by Express Pipeline Ltd. (Express). The pipeline would transport Canadian-produced oil from Hardisty, Alberta, Canada, to Caster, Wyoming. The Express Pipeline is scheduled to be constructed in 1996--97 and will supply crude oil to refineries in Wyoming and the midwest.

  17. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-119 Snohomish-Murray No. 1 Transmission Line

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Mark A. [Bonneville Power Administration (BPA), Portland, OR (United States)

    2003-01-29

    Vegetation Management along the Snohomish-Murray No. 1 Transmission Line from structure 2/6 through structure 18/6. Right of way width is 95 feet. BPA proposes to remove unwanted vegetation along the right-of-way, access roads and around tower structures along the subject transmission line corridor. Total right-of-way acreage is approximately 182.8 acres. Approximately 17 miles of access roads will be cleared. Approximately 136 tower sites will be treated. See Section 1 of the attached checklist for a complete description of the proposal.

  18. Design and simulation of on-chip lossy transmission line pairs

    OpenAIRE

    Demeester, Thomas; De Zutter, Daniël

    2008-01-01

    A quasi-TM reciprocity based multi-conductor transmission line model is used to investigate the influence of the geometry on the performance of on-chip transmission line pairs for high-frequency differential signal transmission. It is shown that both the knowledge of the fundamental transmission line modes and of the internal impedance of both connected circuits, are essential for a good design.

  19. Generating entangled microwave radiation over two transmission lines.

    Science.gov (United States)

    Flurin, E; Roch, N; Mallet, F; Devoret, M H; Huard, B

    2012-11-02

    Using a superconducting circuit, the Josephson mixer, we demonstrate the first experimental realization of spatially separated two-mode squeezed states of microwave light. Driven by a pump tone, a first Josephson mixer generates, out of quantum vacuum, a pair of entangled fields at different frequencies on separate transmission lines. A second mixer, driven by a π-phase shifted copy of the first pump tone, recombines and disentangles the two fields. The resulting output noise level is measured to be lower than for the vacuum state at the input of the second mixer, an unambiguous proof of entanglement. Moreover, the output noise level provides a direct, quantitative measure of entanglement, leading here to the demonstration of 6 Mebit · s(-1) (mega entangled bits per second) generated by the first mixer.

  20. Coupling of Electron Spin Ensembles to Superconducting Transmission Line Resonators

    Science.gov (United States)

    Sears, Adam; Schuster, David; Dicarlo, Leo; Bishop, Lev; Ginossar, Eran; Frunzio, Luigi; Wesenberg, Janus; Ardavan, Arzhang; Briggs, Andrew; Moelmer, Klauss; Morton, John; Schoelkopf, Robert

    2010-03-01

    Recent proposals have suggested using a mesoscopic ensemble of electron spins to create a quantum memory for superconducting qubits in solid state systems[1]. Such ensembles can have large cavity couplings (˜MHz) and should have long coherence times. Here we show the measurement and coupling of electron spins in ruby and diamond to multiplexed superconducting coplanar waveguide (CPW) cavities, as well as broadband spectroscopy of ruby using a CPW transmission line. We discuss the application of these techniques to electron spin resonance at low power, millikelvin temperatures, and over many gigahertz and evaluate the suitability of our materials for quantum computing. [4pt] [1] Wesenberg J et al 2009 Phys. Rev. Lett. 103 070502

  1. A modular restoration tower for electric power line transmission

    Energy Technology Data Exchange (ETDEWEB)

    Nicolazzi, L.C.; Pereira, J.C.; Leonel, C.E.L.; Rocha, G.B.; Bianchezzi, V.; Mendes, F. [Universidade Federal Santa Catarina (UFSC), Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica], Emails: lauro@grante.ufsc.br, jcarlos@grante.ufsc.br; Luz, R.L. [ELETROSUL Centrais Eletricas S.A., Florianopolis, SC (Brazil)], Email: rluz@eletrosul.gov.br

    2009-07-01

    The main target of this R and D project is to develop an restoration tower for electric energy lines transmission. Whereas these towers should present the main features like transport facility, easiest assembling associated with a low cost of manufacture, it was applied the single-column tower concepts supported by stays, modularized, framed and articulated at the base. The concepts used for this development was a design methodology. From the different definition situations of load, numerical models have been developed focusing the design to the best of structural element arrangements of its modules. Then, tests were performed in laboratory to determine the module structural performance for different work load situations. These tests served to identify inconsistencies in the numerical models and proposed adjustments in its design to improve its performance on the strength and stability. (author)

  2. High current nonlinear transmission line based electron beam driver

    Science.gov (United States)

    Hoff, B. W.; French, D. M.; Simon, D. S.; Lepell, P. D.; Montoya, T.; Heidger, S. L.

    2017-10-01

    A gigawatt-class nonlinear transmission line based electron beam driver is experimentally demonstrated. Four experimental series, each with a different Marx bank charge voltage (15, 20, 25, and 30 kV), were completed. Within each experimental series, shots at peak frequencies ranging from 950 MHz to 1.45 GHz were performed. Peak amplitude modulations of the NLTL output voltage signal were found to range between 18% and 35% for the lowest frequency shots and between 5% and 20% for the highest frequency shots (higher modulation at higher Marx charge voltage). Peak amplitude modulations of the electron beam current were found to range between 10% and 20% for the lowest frequency shots and between 2% and 7% for the highest frequency shots (higher modulation at higher Marx charge voltage).

  3. Tailoring of electron flow current in magnetically insulated transmission lines

    Directory of Open Access Journals (Sweden)

    J. P. Martin

    2009-03-01

    Full Text Available It is desirable to optimize (minimizing both the inductance and electron flow the magnetically insulated vacuum sections of low impedance pulsed-power drivers. The goal of low inductance is understandable from basic efficiency arguments. The goal of low electron flow results from two observations: (1 flowing electrons generally do not deliver energy to (or even reach most loads, and thus constitute a loss mechanism; (2 energetic electrons deposited in a small area can cause anode damage and anode plasma formation. Low inductance and low electron flow are competing goals; an optimized system requires a balance of the two. While magnetically insulated systems are generally forgiving, there are times when optimization is crucial. For example, in large pulsed-power drivers used to energize high energy density physics loads, the electron flow as a fraction of total current is small, but that flow often reaches the anode in relatively small regions. If the anode temperature becomes high enough to desorb gas, the resulting plasma initiates a gap closure process that can impact system performance. Magnetic-pressure driven (z pinches and material equation of state loads behave like a fixed inductor for much of the drive pulse. It is clear that neither fixed gap nor constant-impedance transmission lines are optimal for driving inductive loads. This work shows a technique for developing the optimal impedance profile for the magnetically insulated section of a high-current driver. Particle-in-cell calculations are used to validate the impedance profiles developed in a radial disk magnetically insulated transmission line geometry. The input parameters are the spacing and location of the minimum gap, the effective load inductance, and the desired electron flow profile. The radial electron flow profiles from these simulations are in good agreement with theoretical predictions when driven at relatively high voltage (i.e., V≥2  MV.

  4. Evaluation of Fibre Lifetime in Optical Ground Wire Transmission Lines

    Directory of Open Access Journals (Sweden)

    Grunvalds R.

    2017-06-01

    Full Text Available In the research, measurements of polarisation mode dispersion of two OPGWs (optical ground wire transmission lines, in total four fibres, have been carried out, and the expected lifetime of the infrastructure has been assessed on the basis of these measurements. The cables under consideration were installed in 1995 and 2011, respectively. Measurements have shown that polarisation mode dispersion values for cable installed in 1995 are four times higher than that for cable installed in 2011, which could mainly be explained by technological differences in fibre production and lower fibre polarisation mode dispersion requirements in 1995 due to lack of high-speed (over 10 Gbit/s optical transmission systems. The calculation methodology of non-refusal work and refusal probabilities, using the measured polarisation mode dispersion parameters, is proposed in the paper. Based on reliability calculations, the expected lifetime is then predicted, showing that all measured fibres most likely will be operational within minimum theoretical service life of 25 years accepted by the industry.

  5. Evaluation of Fibre Lifetime in Optical Ground Wire Transmission Lines

    Science.gov (United States)

    Grunvalds, R.; Ciekurs, A.; Porins, J.; Supe, A.

    2017-06-01

    In the research, measurements of polarisation mode dispersion of two OPGWs (optical ground wire transmission lines), in total four fibres, have been carried out, and the expected lifetime of the infrastructure has been assessed on the basis of these measurements. The cables under consideration were installed in 1995 and 2011, respectively. Measurements have shown that polarisation mode dispersion values for cable installed in 1995 are four times higher than that for cable installed in 2011, which could mainly be explained by technological differences in fibre production and lower fibre polarisation mode dispersion requirements in 1995 due to lack of high-speed (over 10 Gbit/s) optical transmission systems. The calculation methodology of non-refusal work and refusal probabilities, using the measured polarisation mode dispersion parameters, is proposed in the paper. Based on reliability calculations, the expected lifetime is then predicted, showing that all measured fibres most likely will be operational within minimum theoretical service life of 25 years accepted by the industry.

  6. Big George to Carter Mountain 115-kV transmission line project, Park and Hot Springs Counties, Wyoming. Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-01

    The Western Area Power Administration (Western) is proposing to rebuild, operate, and maintain a 115-kilovolt (kV) transmission line between the Big George and Carter Mountain Substations in northwest Wyoming (Park and Hot Springs Counties). This environmental assessment (EA) was prepared in compliance with the National Environmental Policy Act (NEPA) and the regulations of the Council on Environmental Quality (CEQ) and the Department of Energy (DOE). The existing Big George to Carter Mountain 69-kV transmission line was constructed in 1941 by the US Department of Interior, Bureau of Reclamation, with 1/0 copper conductor on wood-pole H-frame structures without an overhead ground wire. The line should be replaced because of the deteriorated condition of the wood-pole H-frame structures. Because the line lacks an overhead ground wire, it is subject to numerous outages caused by lightning. The line will be 54 years old in 1995, which is the target date for line replacement. The normal service life of a wood-pole line is 45 years. Under the No Action Alternative, no new transmission lines would be built in the project area. The existing 69-kV transmission line would continue to operate with routine maintenance, with no provisions made for replacement.

  7. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    Energy Technology Data Exchange (ETDEWEB)

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  8. Overhead Transmission Lines Deicing under Different Incentive Displacement

    Directory of Open Access Journals (Sweden)

    Qing He

    2014-01-01

    Full Text Available Overhead transmission line icing is one of the main factors affecting safety and reliability of power grid. This paper proposed an excitation deicing method of iced wire and theoretically revealed the ice removal mechanism under displacement excitation conditions, by taking the LGJ-70/10 glaze icing wire as the 3D model and analyzing and studying its dynamic response under the effect of displacement excitation. The simulation results show that the stress of wire icing area is enlarged with the increase of excitation displacement and frequency. Through the comparison of the compression strength experimental results on a series of different iced wires in low temperature environment, the authors found out that the stress generated from the wire icing area is greater than the crushing strength of the ice within the scope of the calculation parameters, which proved the validity and the feasibility of the method, and finally the suitable excitation displacement is determined. Following studies show that, as far as possible, it is necessary to reduce the incentive displacement and also to select the appropriate constraint length in order to avoid the line jumping that may be caused by large span ice shedding.

  9. Electric Power High-Voltage Transmission Lines: Design Options, Cost, and Electric and Magnetic Field Levels

    Energy Technology Data Exchange (ETDEWEB)

    Stoffel, J. B. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division. Electronics and Computing Technologies Division; Pentecost, E. D. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division; Roman, R. D. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division; Traczyk, P. A. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division

    1994-11-01

    The aim of this report is to provide background information about (1) the electric and magnetic fields (EMFs) of high-voltage transmission lines at typical voltages and line configurations and (2) typical transmission line costs to assist preparers and reviewers of the section on alternatives in environmental documents. This report will give the reviewing individual a better appreciation of the factors affecting EMF strengths near high-voltage transmission lines and the approaches that might be used to reduce EMF impacts on humans and other biological species in the vicinity of high-voltage overhead or underground alternating-current (ac) or direct-current (dc) transmission lines.

  10. Structural health monitoring of compression connectors for overhead transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong [ORNL; Wang, Jy-An John [ORNL; Swindeman, Joseph P [ORNL; Ren, Fei [ORNL; Chan, John [Electric Power Research Institute (EPRI)

    2017-01-01

    Two-stage aluminum conductor steel-reinforced (ACSR) compression connectors are extensively used in US overhead transmission lines. The connectors are made by crimping a steel sleeve onto a steel core and an aluminum sleeve over aluminum conductive strands. The connectors are designed to operate at temperatures up to 125 C, but their performance is increasingly degrading because of overloading of lines. Currently, electric utilities conduct routine line inspections using thermal and electrical measurements. However, information about the structural integrity of connectors cannot be obtained. In this work, structural health monitoring (SHM) of compression connectors was studied using electromechanical impedance (EMI) analysis. Lead zirconate titanate (PZT)-5A was identified as a smart material for SHM. A flexible high-temperature bonding layer was used to address challenges in PZT integration due to a significant difference in the coefficients of thermal expansion of PZT and the aluminum substrate. The steel joint on the steel core was investigated because it is responsible for the ultimate tensile strength of the connector. Tensile testing was used to create structural damage to the joint, or steel core pullout, and thermal cycling introduced additional structural perturbations. EMI measurements were conducted between the tests. The root mean square deviation (RMSD) of EMI was identified as a damage index. The use of steel joints has been shown to enable SHM under simulated conditions. The EMI signature is sensitive to variations in structural conditions. RMSD can be correlated to the structural health of a connector and has potential for use in the SHM and structural integrity evaluation.

  11. Structural health monitoring of compression connectors for overhead transmission lines

    Science.gov (United States)

    Wang, Hong; Wang, Jy-An John; Swindeman, Joseph P.; Ren, Fei; Chan, John

    2017-04-01

    Two-stage aluminum conductor steel-reinforced (ACSR) compression connectors are extensively used in US overhead transmission lines. The connectors are made by crimping a steel sleeve onto a steel core and an aluminum sleeve over electrical conducting aluminum strands. The connectors are designed to operate at temperatures up to 125°C, but their performance is increasingly degrading because of overloading of lines. Currently, electric utilities conduct routine line inspections using thermal and electrical measurements, but these methods do not provide information about the structural integrity of connectors. In this work, structural health monitoring (SHM) of compression connectors was studied using electromechanical impedance (EMI) analysis. Lead zirconate titanate (PZT)-5A was identified as a smart material for SHM. A flexible high-temperature bonding layer was used to address challenges in PZT integration due to a significant difference in the coefficients of thermal expansion of PZT and the aluminum substrate. The steel joint on the steel core was investigated because it is responsible for the ultimate tensile strength of the connector. Tensile testing was used to induce structural damage to the joint, or steel core pullout, and thermal cycling introduced additional structural perturbations. EMI measurements were conducted between the tests. The root mean square deviation (RMSD) of EMI was identified as a damage index. The use of steel joints has been shown to enable SHM under simulated conditions. The EMI signature is sensitive to variations in structural conditions. RMSD can be correlated to the structural health of a connector and has potential for use in the SHM and structural integrity evaluation.

  12. A parametric study of nonlinear seismic response analysis of transmission line structures.

    Science.gov (United States)

    Tian, Li; Wang, Yanming; Yi, Zhenhua; Qian, Hui

    2014-01-01

    A parametric study of nonlinear seismic response analysis of transmission line structures subjected to earthquake loading is studied in this paper. The transmission lines are modeled by cable element which accounts for the nonlinearity of the cable based on a real project. Nonuniform ground motions are generated using a stochastic approach based on random vibration analysis. The effects of multicomponent ground motions, correlations among multicomponent ground motions, wave travel, coherency loss, and local site on the responses of the cables are investigated using nonlinear time history analysis method, respectively. The results show the multicomponent seismic excitations should be considered, but the correlations among multicomponent ground motions could be neglected. The wave passage effect has a significant influence on the responses of the cables. The change of the degree of coherency loss has little influence on the response of the cables, but the responses of the cables are affected significantly by the effect of coherency loss. The responses of the cables change little with the degree of the difference of site condition changing. The effect of multicomponent ground motions, wave passage, coherency loss, and local site should be considered for the seismic design of the transmission line structures.

  13. A Parametric Study of Nonlinear Seismic Response Analysis of Transmission Line Structures

    Directory of Open Access Journals (Sweden)

    Li Tian

    2014-01-01

    Full Text Available A parametric study of nonlinear seismic response analysis of transmission line structures subjected to earthquake loading is studied in this paper. The transmission lines are modeled by cable element which accounts for the nonlinearity of the cable based on a real project. Nonuniform ground motions are generated using a stochastic approach based on random vibration analysis. The effects of multicomponent ground motions, correlations among multicomponent ground motions, wave travel, coherency loss, and local site on the responses of the cables are investigated using nonlinear time history analysis method, respectively. The results show the multicomponent seismic excitations should be considered, but the correlations among multicomponent ground motions could be neglected. The wave passage effect has a significant influence on the responses of the cables. The change of the degree of coherency loss has little influence on the response of the cables, but the responses of the cables are affected significantly by the effect of coherency loss. The responses of the cables change little with the degree of the difference of site condition changing. The effect of multicomponent ground motions, wave passage, coherency loss, and local site should be considered for the seismic design of the transmission line structures.

  14. Analysis and applications of OSRR- and OCSRR-loaded transmission lines: A new path for the design of compact transmission line metamaterials

    Science.gov (United States)

    Durán-Sindreu, Miguel; Aznar, Francisco; Vélez, Adolfo; Bonache, Jordi; Martín, Ferran

    2010-08-01

    The main aim of this work is to carry out an exhaustive analysis of transmission lines loaded with open split ring resonators (OSRRs) and open complementary split ring resonators (OCSRRs). These particles are electrically small open resonators (inspired in the split ring resonator—SRR), which can be series or shunt connected to a host transmission line for the synthesis of microwave components, including designs based on transmission line metamaterials. We will analyze both microstrip and coplanar waveguide (CPW) transmission lines loaded with OSRRs and OCSRRs, and we will show that by combining both open resonators (OSRRs and OCSRRs), it is possible to implement composite right/left handed (CRLH) lines with similar characteristics to those based on the CL-loaded approach.

  15. 49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Open-wire transmission line; clearance to other... line; clearance to other circuits. Open-wire transmission line operating at voltage of 750 volts or... THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES...

  16. Transmission line resonance technique for eccentric core optical fibers

    Science.gov (United States)

    Georgantzos, E.; Boucouvalas, A. C.

    2016-12-01

    In several cases optical fibers in telecommunications have cores of non circular geometry. Fibre optic deformations appear in optical fibres for many reasons. Optical fibre core ellipticity for example where the fibre optic core is not perfectly circular due to fibre optic manufacturing tolerances, is measured and often is a problem. Optical fibre core eccentricity, where the fibre core is not on the axis of the fibre, but it is offset by a small length. This is another issue and very important for ensuring performance low loss splices and connector losses. Both of ellipticity and eccentricity are specified in accordance to international standards for fibre optic manufacturing telecommunications grade fibres. The present paper studies ellipticity and core eccentricity specifically and presents a new method for analysing their effect. We present an extension of the transmission line technique as a means of studying such fibers and deriving necessary parameters. Conformal mapping on the other hand is a simple mathematical tool by which we can generate sets of orthogonal two-dimensional coordinate systems. Shortly a conformal map of Cartesian two-dimensional space is defined by any analytical function W(z) where z, w, are: z = x + jy, W = θ + j φ The function deriving by the conformal mapping transformation h(θ ,φ )=| ∂w/∂z | = 1/|∂z/∂w|, can be used in order to define ∇A → and ∇×A → where A → is the magnetic or electric field in the derived orthogonal coordinate system. Useful conformal maps for fiber optics applications should have the property that the equation θ(x, y) = constant, is forming closed curves in a Cartesian two-dimensional space (x,y). If θ(x, y) = constant represents a set of co-eccentric circles, we obtain the normal case of conventional fibers with circular cores. If θ(x, y) = constant represents a set of eclipses, we are have the formation of elliptic core optical fibers. If θ(x, y) = constant represents a set of

  17. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-25) - Ostrander-Pearl Transmission Line

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, Elaine S. [Bonneville Power Administration (BPA), Portland, OR (United States)

    2001-09-05

    Vegetation Management along selected ROW sections of the Ostrander-Pearl transmission line. The ROWs include sections of the Ostrander-Pearl 500 kV line; the Ostrander-McLoughlin 500 kV line; the Big Eddy-Chemawa 230 kV line and the Big Eddy-McLoughlin 230 kV line. BPA proposes to clear unwanted vegetation in the rights-of-way and around tower structures that may impede the operation and maintenance of the subject transmission lines. The project also includes clearing approximately 3 miles of access road and cutting of some danger trees. All work will be in accordance with the National Electrical Safety Code and BPA Standards. BPA plans to conduct vegetation control with the goal of removing tall-growing vegetation that is currently or will soon be a hazard to the transmission lines and to promote low-growing plant communities in the right-of-way and to clear vegetation from new rights-of-way corridors.

  18. Identification and Estimation of Erroneous Transmission Line Parameters Using PMU Measurements

    OpenAIRE

    Markos Asprou; Elias Kyriakides

    2017-01-01

    The accurate knowledge of the transmission line parameters can be beneficial for several monitoring and control applications accommodated in the power system control center. Actually transmission line parameters are stored in the control center databases (assuming that they are time invariant); however, the databases might be obsolete and contain erroneous parameters. This paper proposes a methodology for identifying and estimating the erroneous transmission line parameters using measurements...

  19. Dependence of NMR noise line shapes on tuning, matching, and transmission line properties.

    Science.gov (United States)

    Bendet-Taicher, Eli; Müller, Norbert; Jerschow, Alexej

    2014-02-01

    The tuning and matching conditions of rf circuits, as well as the properties of the transmission lines connecting these to the preamplifier, have direct consequences for NMR probe sensitivity and as for the optimum delivery of rf power to the sample. In addition, tuning/matching conditions influence radiation damping effects, which manifest themselves as fast signal flip-back and line broadening effects, and can lead to concentration-dependent frequency shifts. Previous studies have also shown that the appearance of spin-noise and absorbed circuit noise signals heavily depended on tuning settings. Consequently, all these phenomena are linked together. The mutual connections and interdependences of these effects are highlighted and reviewed here.

  20. Reduction of the visual impact of overhead transmission line systems through utilisation of line surge arresters as lightning protection

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    The main reason for the increasing public resistance to overhead transmission line systems in Denmark is the impact on the environment with emphasis on the visual aspect. Therefore the Danish Transmission System Operator Energinet.dk is currently carrying out a research project, in cooperation...... in line performance and lightning protection of the nearest substations requires thorough modelling of the new line including all electrical parameters necessary for performance evaluation under all conditions. In this paper, explicit use of line surge arresters as lightning protection on the line...

  1. 76 FR 78235 - Dairyland Power Cooperative: CapX 2020 Hampton-Rochester-La Crosse Transmission Line Project

    Science.gov (United States)

    2011-12-16

    ...-kilovolt (kV) transmission line and associated infrastructure between Hampton, Minnesota and the La Crosse... 345-kV transmission line and associated infrastructure, includes 161-kV transmission lines in the... transmission line length of approximately 150 miles. Counties through which the proposed project may pass...

  2. 75 FR 63141 - Apalachicola National Forest; Florida; City of Tallahassee 230kV Southwestern Transmission Line

    Science.gov (United States)

    2010-10-14

    ... 230kV electric transmission line. The addition of an east-west 230kV transmission line would connect the Hopkins--Crawfordville 230kV transmission line south of the Tallahassee Regional Airport (near the... S.W./Woodville Highway intersection). The proposed transmission line would be approximately 8 miles...

  3. Magnetic insulation in triplate and coaxial vacuum transmission lines. Report PIFR-1009

    Energy Technology Data Exchange (ETDEWEB)

    Di Capua, M.; Pellinen, D.G.

    1980-08-01

    An experimental investigation was made of magnetically insulated transmission lines for use in an electron beam fusion accelerator. The magnetically insulated vacuum transmission lines would transfer the power pulses from many modules to a single diode region or multiple diodes to generate currents on the order of 100 MA. This approach may allow present limits on power flow through dielectric vacuum interfaces to be overcome. We have investigated symmetric parallel plate (triplate) transmission lines with a wave impedance of 24 ..cap omega.. and a spacing of 1.9 cm, and coaxial transmission lines (coax) with a wave impedance of 42 ..cap omega.. and a spacing of 2.9 cm.

  4. Research on electric field distribution of UHVDC transmission lines and body surface during live working

    Science.gov (United States)

    Jiang, Chilong; Zou, Dehua; Li, Jinliang; Zhang, Zhanlong; Mei, Daojun

    2017-09-01

    Electric field distortion emerges around personnel working on live Ultra High Voltage Direct Current UHVDC transmission lines, especially when they move from ground-potential to equipotential positions. Unreliable protection threatens the safety of both workers and transmission lines. The current study investigates the electric field distribution of body surface during live working under transmission lines. To provide safety advice, live working person and tower models were established. The body surface field was calculated in different positions under ±800 kV transmission lines, and the distribution of the electric field was summarized.

  5. Cooling a Micromechanical Beam by Coupling it to a Transmission Line

    OpenAIRE

    Xue, Fei; Wang, Y. D.; Liu, Yu-xi; Nori, Franco

    2007-01-01

    We study a method to cool down the vibration mode of a micro-mechanical beam using a capacitively-coupled superconducting transmission line. The Coulomb force between the transmission line and the beam is determined by the driving microwave on the transmission line and the displacement of the beam. When the frequency of the driving microwave is smaller than that of the transmission line resonator, the Coulomb force can oppose the velocity of the beam. Thus, the beam can be cooled. This mechan...

  6. INSTRUMENTATION FOR SURVEYING ACOUSTIC SIGNALS IN NATURAL GAS TRANSMISSION LINES

    Energy Technology Data Exchange (ETDEWEB)

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Deepak Mehra

    2003-09-01

    In the U.S. natural gas is distributed through more than one million miles of high-pressure transmission pipelines. If all leaks and infringements could be detected quickly, it would enhance safety and U.S. energy security. Only low frequency acoustic waves appear to be detectable over distances up to 60 km where pipeline shut-off valves provide access to the inside of the pipeline. This paper describes a Portable Acoustic Monitoring Package (PAMP) developed to record and identify acoustic signals characteristic of: leaks, pump noise, valve and flow metering noise, third party infringement, manual pipeline water and gas blow-off, etc. This PAMP consists of a stainless steel 1/2 inch NPT plumbing tree rated for use on 1000 psi pipelines. Its instrumentation is designed to measure acoustic waves over the entire frequency range from zero to 16,000 Hz by means of four instruments: (1) microphone, (2) 3-inch water full range differential pressure transducer with 0.1% of range sensitivity, (3) a novel 3 inch to 100 inch water range amplifier, using an accumulator with needle valve and (4) a line-pressure transducer. The weight of the PAMP complete with all accessories is 36 pounds. This includes a remote control battery/switch box assembly on a 25-foot extension chord, a laptop data acquisition computer on a field table and a sun shield.

  7. Precision electron flow measurements in a disk transmission line.

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Waylon T.; Pelock, Michael D.; Martin, Jeremy Paul; Jackson, Daniel Peter Jr.; Savage, Mark Edward; Stoltzfus, Brian Scott; Mendel, Clifford Will, Jr.; Pointon, Timothy David

    2008-01-01

    An analytic model for electron flow in a system driving a fixed inductive load is described and evaluated with particle in cell simulations. The simple model allows determining the impedance profile for a magnetically insulated transmission line given the minimum gap desired, and the lumped inductance inside the transition to the minimum gap. The model allows specifying the relative electron flow along the power flow direction, including cases where the fractional electron flow decreases in the power flow direction. The electrons are able to return to the cathode because they gain energy from the temporally rising magnetic field. The simulations were done with small cell size to reduce numerical heating. An experiment to compare electron flow to the simulations was done. The measured electron flow is {approx}33% of the value from the simulations. The discrepancy is assumed to be due to a reversed electric field at the cathode because of the inductive load and falling electron drift velocity in the power flow direction. The simulations constrain the cathode electric field to zero, which gives the highest possible electron flow.

  8. Economic analysis of transmission line engineering based on industrial engineering

    Science.gov (United States)

    Li, Yixuan

    2017-05-01

    The modern industrial engineering is applied to the technical analysis and cost analysis of power transmission and transformation engineering. It can effectively reduce the cost of investment. First, the power transmission project is economically analyzed. Based on the feasibility study of power transmission and transformation project investment, the proposal on the company system cost management is put forward through the economic analysis of the effect of the system. The cost management system is optimized. Then, through the cost analysis of power transmission and transformation project, the new situation caused by the cost of construction is found. It is of guiding significance to further improve the cost management of power transmission and transformation project. Finally, according to the present situation of current power transmission project cost management, concrete measures to reduce the cost of power transmission project are given from the two aspects of system optimization and technology optimization.

  9. Analysis of the transient response of a dual-fed RC transmission line.

    Science.gov (United States)

    Dorraki, Mohsen; Cambrell, Gregory K; Abbott, Derek

    2015-01-01

    The transient analysis of a uniform transmission line of finite length is considered in this paper. For the first time this paper provides an analytical expression for the time-domain response of an RC transmission line, which is stimulated by a step function that is fed into both ends of the transmission line. In particular, we find an analytical expression for the step response at the center of the transmission line, in order to determine the worst-case rise time. This is of interest, for example, in large charge-coupled device (CCD) arrays, where long polysilicon lines are dual-fed in order to mitigate degradation in rise time. The analytical expressions for the RC transmission line are supported by computer-simulated lumped RC models.

  10. Analysis of the transient response of a dual-fed RC transmission line.

    Directory of Open Access Journals (Sweden)

    Mohsen Dorraki

    Full Text Available The transient analysis of a uniform transmission line of finite length is considered in this paper. For the first time this paper provides an analytical expression for the time-domain response of an RC transmission line, which is stimulated by a step function that is fed into both ends of the transmission line. In particular, we find an analytical expression for the step response at the center of the transmission line, in order to determine the worst-case rise time. This is of interest, for example, in large charge-coupled device (CCD arrays, where long polysilicon lines are dual-fed in order to mitigate degradation in rise time. The analytical expressions for the RC transmission line are supported by computer-simulated lumped RC models.

  11. Electric Utility Transmission and Distribution Line Engineering Program

    Energy Technology Data Exchange (ETDEWEB)

    Peter McKenny

    2010-08-31

    Economic development in the United States depends on a reliable and affordable power supply. The nation will need well educated engineers to design a modern, safe, secure, and reliable power grid for our future needs. An anticipated shortage of qualified engineers has caused considerable concern in many professional circles, and various steps are being taken nationwide to alleviate the potential shortage and ensure the North American power system's reliability, and our world-wide economic competitiveness. To help provide a well-educated and trained workforce which can sustain and modernize the nation's power grid, Gonzaga University's School of Engineering and Applied Science has established a five-course (15-credit hour) Certificate Program in Transmission and Distribution (T&D) Engineering. The program has been specifically designed to provide working utility engineering professionals with on-line access to advanced engineering courses which cover modern design practice with an industry-focused theoretical foundation. A total of twelve courses have been developed to-date and students may select any five in their area of interest for the T&D Certificate. As each course is developed and taught by a team of experienced engineers (from public and private utilities, consultants, and industry suppliers), students are provided a unique opportunity to interact directly with different industry experts over the eight weeks of each course. Course material incorporates advanced aspects of civil, electrical, and mechanical engineering disciplines that apply to power system design and are appropriate for graduate engineers. As such, target students for the certificate program include: (1) recent graduates with a Bachelor of Science Degree in an engineering field (civil, mechanical, electrical, etc.); (2) senior engineers moving from other fields to the utility industry (i.e. paper industry to utility engineering or project management positions); and (3) regular

  12. Extragalactic circuits, transmission lines, and CR particle acceleration

    Directory of Open Access Journals (Sweden)

    Kronberg Philipp P.

    2015-01-01

    Full Text Available A non-negligible fraction of a Supermassive Black Hole's (SMBH rest mass energy gets transported into extragalactic space by a remarkable process in jets which are incompletely understood. What are the physical processes which transport this energy? It is likely that the energy flows electromagnetically, rather than via a particle beam flux. The deduced electromagnetic fields may produce particles of energy as high as ∼ 1020 eV. The energetics of SMBH accretion disk models and the electromagnetic energy transfer imply that a SMBH should generate a 1018 − 1019 Ampères current close to the black hole and its accretion disk. We describe the so far best observation-based estimate of the magnitude of the current flow along the axis of the jet extending from the nucleus of the active galaxy in 3C303. The current is measured to be I ∼ 1018 Ampères at ∼ 40 kpc away from the AGN. This indicates that organised current flow remains intact over multi-kpc distances. The electric current I transports electromagnetic power into free space, P = I2Z, where Z ∼ 30 Ohms is related to the impedance of free space, and this points to the existence of cosmic electric circuit. The associated electric potential drop, V = IZ, is of the order of that required to generate Ultra High Energy Cosmic Rays (UHECR. We also explore further implications, including disruption/deflection of the power flow and also why such measurements, exemplified by those on 3C303, are currently very difficult to make and to unambiguously interpret. This naturally leads to the topic of how such measurements can be extended and improved in the future. We describe the analogy of electromagnetically dominated jets with transmission lines. High powered jets in vacuo can be understood by approximate analogy with a waveguide. The importance of inductance, impedance, and other laboratory electrical concepts are discussed in this context.

  13. Recent progress of the improved magnetically insulated transmission line oscillator.

    Science.gov (United States)

    Fan, Yu-Wei; Zhong, Hui-Huang; Li, Zhi-Qiang; Shu, Ting; Zhang, Jian-De; Liu, Jin-Liang; Yang, Jian-Hua; Zhang, Jun; Yuan, Cheng-Wei; Luo, Ling

    2008-03-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube driven by a 550 kV, 57 kA, 50 ns electron beam. It has allowed us to generate 2.4 GW pulse of 22 ns duration. The recent progress of the improved MILO is presented in this paper. First, a field shaper cathode is introduced into the improved MILO to avoid the cathode flares in the triple point region. The experimental results show that the cathode flares are avoided, so the lifetime of the velvet cathode is longer than that of the taper cathode. Furthermore, the shot-to-shot reproducibility is better than that of the taper cathode. Second, In order to prolong the pulse duration and increase the radiated microwave power, a self-built 600 kV, 10 Omega, 80 ns pulser: SPARK-03 is employed to drive the improved MILO. Simulation and experimental investigation are performed. In simulation, when the improved MILO is driven by a 600 kV, 57 kA electron beam, high-power microwave is generated with output power of 4.15 GW, frequency of 1.76 GHz, and relevant power conversion efficiency of 12.0%. In experiments, when the diode voltage is 550 kV and current is 54 kA, the measured results are that the radiated microwave power is above 3.1 GW, the pulse duration is above 40 ns, the microwave frequency is about 1.755 GHz, and the power conversion efficiency is about 10.4%.

  14. Transmission line analogy for relativistic Poynting-flux jets

    Science.gov (United States)

    Lovelace, R. V. E.; Kronberg, P. P.

    2013-04-01

    Radio emission, polarization and Faraday rotation maps of the radio jet of the galaxy 3C 303 have shown that one knot of this jet carries a galactic-scale electric current and that it is magnetically dominated. We develop the theory of magnetically dominated or Poynting-flux jets by making an analogy of a Poynting jet with a transmission line or waveguide carrying a net current and having a potential drop across it (from the jet's axis to its radius) and a definite impedance which we derive. The electromagnetic energy flow in the jet is the jet impedance times the square of the jet current. The observed current in 3C 303 can be used to calculate the electromagnetic energy flow in this magnetically dominated jet. Time dependent but not necessarily small perturbations of a Poynting-flux jet are described by the `telegrapher's equations'. These predict the propagation speed of disturbances and the effective wave impedance for forward and backward propagating wave components. A localized disturbance of a Poynting jet gives rise to localized dissipation in the jet which may explain the enhanced synchrotron radiation in the knots of the 3C 303 jet, and also in the apparently stationary knot HST-1 in the jet near the nucleus of the nearby galaxy M87. For a relativistic Poynting jet on parsec scales, the reflected voltage wave from an inductive termination or load can lead to a backward propagating wave which breaks down the magnetic insulation of the jet giving |{boldsymbol E}| /|{boldsymbol B}|ge 1. At the threshold for breakdown, |{boldsymbol E}|/|{boldsymbol B}|=1, positive and negative particles are directly accelerated in the {boldsymbol E} × {boldsymbol B} direction which is approximately along the jet axis. Acceleration can occur up to Lorentz factors ˜107. This particle acceleration mechanism is distinct from that in shock waves and that in magnetic field reconnection.

  15. Note: fast double pulse system using transmission line characteristic of the pulse forming line.

    Science.gov (United States)

    Sharma, Surender Kumar; Deb, P; Sharma, Archana; Shyam, A

    2012-11-01

    A fast double pulse system is designed and developed using the transmission line characteristic of the pulse forming line to generate two flat top rectangular pulses with extremely short interpulse repetition interval. The helical pulse forming line (HPFL) is used to generate longer duration rectangular pulses in smaller length. The HPFL inner conductor is made up of 13 turns of SS-304 strip, 39.5 mm wide and 0.5 mm thick wounded on the 168 mm delrin cylinder. The impedance of the HPFL is 22 Ω. The 2 turns at the input side of the HPFL are wounded with ethylene propylene rubber tape on the strip. The HPFL is charged to 180 kV in 4 μs and discharges into a matched load through a spark switch. It generates two flat top rectangular pulses of 90 kV, 100 ns duration with the 30 ns interval between the pulses. The system can be used as fast double pulse source for repetitive pulsed power loads.

  16. Long-distance pulse propagation on high-frequency dissipative nonlinear transmission lines/resonant tunneling diode line cascaded maps

    Energy Technology Data Exchange (ETDEWEB)

    Klofai, Yerima [Department of Physics, Higher Teacher Training College, University of Maroua, PO Box 46 Maroua (Cameroon); Essimbi, B Z [Department of Physics, Faculty of Science, University of Yaounde 1, PO Box 812 Yaounde (Cameroon); Jaeger, D, E-mail: bessimb@yahoo.fr [ZHO, Optoelectronik, Universitaet Duisburg-Essen, D-47048 Duisburg (Germany)

    2011-10-15

    Pulse propagation on high-frequency dissipative nonlinear transmission lines (NLTLs)/resonant tunneling diode line cascaded maps is investigated for long-distance propagation of short pulses. Applying perturbative analysis, we show that the dynamics of each line is reduced to an expanded Korteweg-de Vries-Burgers equation. Moreover, it is found by computer experiments that the soliton developed in NLTLs experiences an exponential amplitude decay on the one hand and an exponential amplitude growth on the other. As a result, the behavior of a pulse in special electrical networks made of concatenated pieces of lines is closely similar to the transmission of information in optical/electrical communication systems.

  17. Avoidance of Pressure Oscillations in Discrete Fluid Power Systems with Transmission Lines - An Analytical Approach

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.

    2014-01-01

    transmission lines often impose pressure oscillation/ pressure waves to occur in systems operated discrete or very fast. The current work focus on developing an analytical algorithm computing the flow requirement into a cylinder chamber through a transmission line that will impose a smooth pressure change...

  18. Generalized analysis of UHF transmission-lines juction twoport with the wire coupling element

    OpenAIRE

    Zakhariya, Y. A.; Kobilyanska, O. V.

    2009-01-01

    The synthesis problem of UHF transmission line junction twoport with the wire exciting element on the multiport loss-free conditions and known input impedance basis is considered. Graphical analysis results open the possibility for junction structure optimization. General conclusions are for width class of transmission lines and exciting elements type valid.

  19. A calibration technique for measuring the complex permittivity of materials with planar transmission lines

    Science.gov (United States)

    A simple two-standard calibration procedure for determining the permittivity of a material from the propagation constant measured with planar transmission lines is presented. The suitability of this procedure is demonstrated by using a coplanar waveguide transmission-line sensor to measure the permi...

  20. Optimal Value of Series Capacitors for Uniform Field Distribution in Transmission Line MRI Coils

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy

    2016-01-01

    Transmission lines are often used as coils in high field magnetic resonance imaging (MRI). Due to the distributed nature of transmission lines, coils based on them produce inhomogeneous field. This work investigates application of series capacitors to improve field homogeneity along the coil...

  1. Some Little-Known Facts about Transmission Lines and Some New Results

    Science.gov (United States)

    Dutta Roy, Suhash C.

    2010-01-01

    The study of transmission lines forms an integral part of any curriculum in electrical engineering. This paper presents some little-known but interesting facts about transmission lines, which are generally not found in textbooks, along with some new facts, which arose as extensions of these little-known ones. The facts highlighted in this paper…

  2. Line Capacity Expansion and Transmission Switching in Power Systems With Large-Scale Wind Power

    DEFF Research Database (Denmark)

    Villumsen, Jonas Christoffer; Bronmo, Geir; Philpott, Andy B.

    2013-01-01

    In 2020 electricity production from wind power should constitute nearly 50% of electricity demand in Denmark. In this paper we look at optimal expansion of the transmission network in order to integrate 50% wind power in the system, while minimizing total fixed investment cost and expected cost...... of power generation. We allow for active switching of transmission elements to reduce congestion effects caused by Kirchhoff's voltage law. Results show that actively switching transmission lines may yield a better utilization of transmission networks with large-scale wind power and increase wind power...... penetration. Furthermore, it is shown that transmission switching is likely to affect the optimal line capacity expansion plan....

  3. Lightning Current Observation on UHVAC Transmission Lines by Improved Magnetic Steel Rod Method

    Directory of Open Access Journals (Sweden)

    Anfeng Jiang

    2014-09-01

    Full Text Available Lightning stroke is the main threaten to the safe operation of UHVAC transmission lines. The magnetic steel rod method had been widely used as a traditional method for lightning accident and lightning current investigation in high voltage transmission lines. For the application of the magnetic steel rod method on UHVAC transmission lines, this paper proposed a practical and easy improved method of installing the magnetic steel rods directly on the transmission towers. The residual magnetism curve and accuracy verification of the proposed method was obtained through complex steel structure impulse current experiments. The magnetic steel rod location on UHVAC transmission tower was analyzed by the numerical analysis software MagNet. The application results of the proposed method on the first demonstration and test UHVAC transmission line is presented. The obtained datasets after one storm season was analyzed through Electromagnetic Transients Program. It is shown that the proposed method is feasible.

  4. A study of electric transmission lines for use on the lunar surface

    Science.gov (United States)

    Gaustad, Krista L.; Gordon, Lloyd B.; Weber, Jennifer R.

    1994-01-01

    The sources for electrical power on a lunar base are said to include solar/chemical, nuclear (static conversion), and nuclear (dynamic conversion). The transmission of power via transmission lines is more practical than power beaming or superconducting because of its low cost and reliable, proven technology. Transmission lines must have minimum mass, maximum efficiency, and the ability to operate reliably in the lunar environment. The transmission line design includes conductor material, insulator material, conductor geometry, conductor configuration, line location, waveform, phase selection, and frequency. This presentation oulines the design. Liquid and gaseous dielectrics are undesirable for long term use in the lunar vacuum due to a high probability of loss. Thus, insulation for high voltage transmission line will most likely be solid dielectric or vacuum insulation.

  5. Review and Latest Trends in Mobile Robots Used on Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    Rogério Sales Gonçalves

    2013-12-01

    Full Text Available This paper presents the current state of the art in mobile robots used on power transmission lines. Many theoretical and experimental studies have been conducted in order to develop autonomous machines to travel along transmission lines to perform inspection and/or repair work. These machines can improve efficiency, reduce labour costs and are expected to reduce the risk of injury to maintenance personnel. Despite there already being a number of pieces of theoretical research and technological developments in this area, problems related to stability, ability and autonomy still exist. As such, first this paper presents the main studies already carried out and the devices generally used on power transmission lines. After the latest trends have been presented, a new idea for module robots carrying out inspections/maintenance of power transmission lines is presented. Finally, the future of mobile robots applied to power transmission lines is discussed.

  6. Implementation Of Thyristor Controlled Series Capacitor (TCSC) In Transmission Line Model Using Arduino

    OpenAIRE

    Dr J.Sridevi

    2014-01-01

    A grid of transmission lines operating at high or extra high voltages is required to transmit power from generating stations to load. In addition to transmission lines that carry power from source to load, modern power systems are highly interconnected for economic reasons. The large interconnected transmission networks are prone to faults due to the lightning discharges and reduce insulation strength. Changing of loads and atmosphere conditions are unpredictable factors. This...

  7. Millimeter-Gap Magnetically Insulated Transmission Line Power Flow Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Hutsel, Brian Thomas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stoltzfus, Brian S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Fowler, William E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LeChien, Keith R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mazarakis, Michael G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Moore, James K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mulville, Thomas D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Savage, Mark E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stygar, William A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); McKenney, John L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Peter A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); MacRunnels, Diego J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Long, Finis W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Porter, John L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    An experiment platform has been designed to study vacuum power flow in magnetically insulated transmission lines (MITLs). The platform was driven by the 400-GW Mykonos-V accelerator. The experiments conducted quantify the current loss in a millimeter-gap MITL with respect to vacuum conditions in the MITL for two different gap distances, 1.0 and 1.3 mm. The current loss for each gap was measured for three different vacuum pump down times. As a ride along experiment, multiple shots were conducted with each set of hardware to determine if there was a conditioning effect to increase current delivery on subsequent shots. The experiment results revealed large differences in performance for the 1.0 and 1.3 mm gaps. The 1.0 mm gap resulted in current loss of 40%-60% of peak current. The 1.3 mm gap resulted in current losses of less than 5% of peak current. Classical MITL models that neglect plasma expansion predict that there should be zero current loss, after magnetic insulation is established, for both of these gaps. The experiments result s indicate that the vacuum pressure or pump down time did not have a significant effect on the measured current loss at vacuum pressures between 1e-4 and 1e-5 Torr. Additionally, there was not repeatable evidence of a conditioning effect that reduced current loss for subsequent full-energy shots on a given set of hardware. It should be noted that the experiments conducted likely did not have large loss contributions due to ion emission from the anode due to the relatively small current densi-ties (25-40 kA/cm) in the MITL that limited the anode temperature rise due to ohmic heating. The results and conclusions from these experiments may have limited applicability to MITLs of high current density (>400 kA/cm) used in the convolute and load region of the Z which experience temperature increases of >400° C and generate ion emission from anode surfaces.

  8. Stillbirth and residential proximity to extremely low frequency power transmission lines: a retrospective cohort study.

    Science.gov (United States)

    Auger, Nathalie; Park, Alison L; Yacouba, Soumana; Goneau, Marc; Zayed, Joseph

    2012-02-01

    The relationship between electromagnetic field exposure and stillbirth has not been evaluated. We assessed associations between residential proximity to extremely low frequency power transmission lines and stillbirth across gestational age. Data included singleton live births (N=514,826) and stillbirths (N=2033) for 1998-2007 in metropolitan areas of Québec, Canada. Using power transmission line maps, the distances between lines and residential six-digit postal codes (lines and odds of stillbirth was not found, but the likelihood of term stillbirth was elevated for residences within 25 m of power transmission lines. Residential proximity to transmission lines is unlikely to be associated with stillbirth, but more research is needed to rule out a possible link.

  9. STUDY OF TRANSMISSION LINES EFFECT ON THE SYSTEM OPERATIONON OF CONTINUOUS AUTOMATIC CAB SIGNALLING

    Directory of Open Access Journals (Sweden)

    O. O. Hololobova

    2014-10-01

    Full Text Available Purpose. To conduct an effect research of the electromagnetic field of high-voltage transmission lines (HVTL (750 kV, 50 Hz on the track circuits and continuous automatic cab signalling (CACS with a signal current of 50 Hz in the areas of convergence and intersection with the transmission lines and to propose possible methods to improve noise immunity of CACS. Methodology. The measurements were performed both by means of car-laboratory and directly on rail lines. During the study the electric field strength in the range of industrial frequency directly under the transmission lines and at the distance from it to the railway lines was measured, as well as the time dependence of CACS codes with signal current frequency of 50 Hz directly under the transmission lines and at a distance from it in the absence of the train and its passing. Findings. The root causes analysis of CACS faults and failures was carried out. The effect of the electromagnetic field of high-voltage transmission lines (750 kV, 50 Hz on the track circuit and CACS with signal current of 50 Hz in the areas of convergence and intersection with the transmission line was investigated. Possible methods to improve noise immunity of CACS were considered. Originality. The effect research of transmission lines (750 kV on the operation of the automatic cab signalling on spans Prishib-Burchatsk and Privolnoye-Yelizarovo, Pridneprovsk railway in places of oblique railroads crossing and transmission lines (750 kV, 50 Hz was conducted. Electric field strength in the range of industrial frequency directly under the transmission lines and at a distance from it to the railway line, as well as the time dependences of ALSN codes with signal current frequency of 50 Hz directly under the transmission lines and at a distance from it in the absence of the train and as its passing were measured. It was found that CACS codes in track circuits under transmission lines are strongly distorted, as strength

  10. Model updating approach for icing forecast of transmission lines by using particle swarm optimization

    Science.gov (United States)

    Tian, Haigang; Liang, Naifeng; Zhao, Puzhi; Wang, Xuan; Zhu, Chuangwei; Zhang, Sanchun; Wang, Wei

    2017-06-01

    With the purpose of predicting icing of transmission lines, a model updating approach is presented in this study. The changes of structural dynamic response of transmission lines that is caused by icing is studied firstly by using finite element method. Then, model updating method and particle swarm optimization is implemented to indentify the thickness of icing according to the alternation of natural frequencies. The results show that the proposed methodology is meaningful to monitor line icing.

  11. Location of Faults in Power Transmission Lines Using the ARIMA Method

    OpenAIRE

    Danilo Pinto Moreira de Souza; Eliane da Silva Christo; Aryfrance Rocha Almeida

    2017-01-01

    One of the major problems in transmission lines is the occurrence of failures that affect the quality of the electric power supplied, as the exact localization of the fault must be known for correction. In order to streamline the work of maintenance teams and standardize services, this paper proposes a method of locating faults in power transmission lines by analyzing the voltage oscillographic signals extracted at the line monitoring terminals. The developed method relates time series models...

  12. On increasing the spectral efficiency and transmissivity in the data transmission channel on the spacecraft-ground tracking station line

    Science.gov (United States)

    Andrianov, M. N.; Kostenko, V. I.; Likhachev, S. F.

    2018-01-01

    The algorithms for achieving a practical increase in the rate of data transmission on the space-craft-ground tracking station line has been considered. This increase is achieved by applying spectral-effective modulation techniques, the technology of orthogonal frequency compression of signals using millimeterrange radio waves. The advantages and disadvantages of each of three algorithms have been revealed. A significant advantage of data transmission in the millimeter range has been indicated.

  13. Lines of monetary transmission optimization under conditions of transition economy

    OpenAIRE

    Lepushynskyy, Volodymyr

    2008-01-01

    An essential condition of the effectiveness of price-stability-based monetary regime is availability of an efficient mechanism for transmission of monetary policy impulses to the real sector of economy. Characteristic of the economy of Ukraine, the same as many other transition economies is the existence of institutional and structural factors that reduce the effectiveness of monetary transmission mechanism. This paper discusses the above mentioned factors and measures aimed to st...

  14. 75 FR 3486 - Susquehanna to Roseland 500kV Transmission Line, Environmental Impact Statement, Delaware Water...

    Science.gov (United States)

    2010-01-21

    ... National Park Service Susquehanna to Roseland 500kV Transmission Line, Environmental Impact Statement... the Susquehanna to Roseland 500kV Transmission Line. SUMMARY: Pursuant to National Environmental..., Pennsylvania) to Roseland, New Jersey 500 kilovolt (kV) Transmission Line. The line is being proposed by...

  15. 77 FR 2268 - Dairyland Power Cooperative: CapX 2020 Hampton-Rochester-La Crosse Transmission Line Project

    Science.gov (United States)

    2012-01-17

    ... construction of a proposed 345-kilovolt (kV) transmission line and associated infrastructure between Hampton... line and associated infrastructure, includes 161-kV transmission lines in the vicinity of Rochester, Minnesota; construction of two new and expansion of three substations, with a total transmission line length...

  16. An integrated backflashover model for insulation coordination of overhead transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Meliopoulos, A.P.S. [Georgia Inst. of Technology, School of Electrical and Computer Engineering, Atlanta, GA (United States); Adams, William; Casey, Robert [Georgia Power Co., Atlanta, GA (United States)

    1997-05-01

    The lightning performance of overhead transmission lines is measured with the probability of backflashover. This probability is affected by (a) tower type, (b) grounding arrangement, (c) soil resistivity and (d) lightning activity and lightning parameters of the area. This paper presents an integrated model of the transmission towers, tower grounding and overhead line conductors. The model is utilized in a Monte Carlo simulation for the purpose of predicting the lightning performance of a transmission line. This paper presents the models and the simulation method. Typical results for typical transmission towers and grounding arrangements are provided. The model reveals that the grounding arrangement as well as the surge impedance of the transmission tower are important parameters affecting line performance. (author)

  17. Transmission characteristics and transmission line model of a metal-insulator-metal waveguide with a stub modified by cuts.

    Science.gov (United States)

    Shen, Xinru; Wang, Yueke; Yan, Xin; Yuan, Lin; Sang, Tian

    2016-08-10

    We propose a structure of a metal-insulator-metal (MIM) waveguide with a stub modified by cuts. Our simulation results, conducted by the finite element method, show that the wavelengths of transmission dip vary with the position of the cuts and form the zigzag lines. A transmission line model is also presented, and it agrees with simulation results well. It is believed that our findings provide a smart way to design a plasmonic waveguide filter at the communication region based on MIM structures.

  18. Sensor, method and system of monitoring transmission lines

    Science.gov (United States)

    Syracuse, Steven J.; Clark, Roy; Halverson, Peter G.; Tesche, Frederick M.; Barlow, Charles V.

    2012-10-02

    An apparatus, method, and system for measuring the magnetic field produced by phase conductors in multi-phase power lines. The magnetic field measurements are used to determine the current load on the conductors. The magnetic fields are sensed by coils placed sufficiently proximate the lines to measure the voltage induced in the coils by the field without touching the lines. The x and y components of the magnetic fields are used to calculate the conductor sag, and then the sag data, along with the field strength data, can be used to calculate the current load on the line and the phase of the current. The sag calculations of this invention are independent of line voltage and line current measurements. The system applies a computerized fitter routine to measured and sampled voltages on the coils to accurately determine the values of parameters associated with the overhead phase conductors.

  19. Nonlinear Waves in Transmission Lines Periodically Loaded with Tunneling Diodes

    OpenAIRE

    Narahara, Koichi

    2010-01-01

    This chapter reviews the pulse propagation characteristics of TD lines.We found that a pulse wave propagates on the line either by theunstable exponential-sinusoidal hybrid mode or stable exponential-exponential mode. Through thesepeculiar wave propagation properties, an input impulse experiences width shortening and an edge of the step pulse oscillates. These provide efficient methods for generating short pulses and continuous waves. Moreover, TD lines can be used to manage pulse amplitude a...

  20. The effect analysis of strain rate on power transmission tower-line system under seismic excitation.

    Science.gov (United States)

    Tian, Li; Wang, Wenming; Qian, Hui

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system.

  1. A planar transmission-line sensor for measuring microwave permittivity of liquid and semisolid biological materials

    Science.gov (United States)

    An accurate technique for determining the permittivity of biological materials with coplanar waveguide transmission line is presented. The technique utilizes closed-form approximations that relate the material permittivity to the line propagation constant. A thru-reflect-line calibration procedure i...

  2. An Efficient Algorithm for Fault Location on Mixed Line-Cable Transmission Corridors

    NARCIS (Netherlands)

    Popov, M.; Rietveld, G.; Radojevic, Z.; Terzija, V.

    2013-01-01

    This paper presents a fault location algorithm that can be used to accurately locate the fault at any place along mixed line-cable transmission corridors. The algorithm is an impedance based line/cable parameter dependent algorithm. The fault location algorithm is derived using distributed line

  3. Planning Electric Transmission Lines: A Review of Recent Regional Transmission Plans

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-04-13

    The first Quadrennial Energy Review (QER) recommends that the U.S. Department of Energy (DOE) conduct a national review of transmission plans and assess the barriers and incentives to their implementation. DOE tasked Lawrence Berkeley National Laboratory (LBNL) to prepare two reports to support the agency’s response to this recommendation. This report reviews regional transmission plans and regional transmission planning processes that have been directed by Federal Energy Regulatory Commission (FERC) Order Nos. 890 and 1000. We focus on the most recent regional transmission plans (those issued in 2015 and through approximately mid-year 2016) and current regional transmission planning processes. A companion report focuses on non-plan-related factors that affect transmission projects.

  4. Research on UAV Intelligent Obstacle Avoidance Technology During Inspection of Transmission Line

    Science.gov (United States)

    Wei, Chuanhu; Zhang, Fei; Yin, Chaoyuan; Liu, Yue; Liu, Liang; Li, Zongyu; Wang, Wanguo

    Autonomous obstacle avoidance of unmanned aerial vehicle (hereinafter referred to as UAV) in electric power line inspection process has important significance for operation safety and economy for UAV intelligent inspection system of transmission line as main content of UAV intelligent inspection system on transmission line. In the paper, principles of UAV inspection obstacle avoidance technology of transmission line are introduced. UAV inspection obstacle avoidance technology based on particle swarm global optimization algorithm is proposed after common obstacle avoidance technologies are studied. Stimulation comparison is implemented with traditional UAV inspection obstacle avoidance technology which adopts artificial potential field method. Results show that UAV inspection strategy of particle swarm optimization algorithm, adopted in the paper, is prominently better than UAV inspection strategy of artificial potential field method in the aspects of obstacle avoidance effect and the ability of returning to preset inspection track after passing through the obstacle. An effective method is provided for UAV inspection obstacle avoidance of transmission line.

  5. A Novel Design of Radio Frequency Energy Relays on Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    Jin Tong

    2016-06-01

    Full Text Available In this paper, we investigate the energy problem of monitoring sensors on high-voltage power transmission lines and propose a wireless charging scheme for a Radio Frequency IDentification (RFID sensor tag to solve a commercial efficiency problem: the maintenance-caused power outage. Considering the environmental influences on power transmission lines, a self-powered wireless energy relay is designed to meet the energy requirement of the passive RFID sensor tag. The relay can obtain the electric field energy from the transmission lines and wirelessly power the RFID sensor tags around for longer operating distance. A prototype of the energy relay is built and tested on a 110 kv line. The measurement results show that the energy relay can provide stable energy even with the influences of wind, noise and power outage. To our knowledge, it is the first work to power the RFID sensor tags on power transmission lines.

  6. Ultrasound transmission spectroscopy: in-line sizing of nanoparticles

    NARCIS (Netherlands)

    Neer, P.L.M.J. van; Volker, A.W.F.; Pierre, G.; Bouvet, F.; Crozat, S.

    2014-01-01

    Nanoparticles are increasingly used in a number of applications, e.g. coatings or paints. To optimize nanoparticle production in-line quantitative measurements of their size distribution and concentration are needed. Ultrasound-based methods are especially suited for in-line particle sizing. These

  7. Insulation recovery characteristics after fault arc interruption on UHV (1000kV class) transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Goda, Yutaka; Matsuda, Shoji; Inaba, Tsuginori; Ozaki, Yuzo (Central Research Inst. of Electric Power Industry, Kanagawa (Japan))

    1993-10-01

    The insulation recovery time after arc interruption must be known to select the adequate reclosing dead time of rapid auto-reclosing on transmission lines. In order to study insulation recovery characteristics after arc interruption on UHV (1,000kV class) transmission lines, many tests were carried out using the high power test facilities of CRIEPI. In this paper they describe the experimental results of these tests of insulation recovery characteristics after arc interruption of UHV transmission lines, and some factors influencing these characteristics.

  8. Simulation of longitudinal differential protection of transmission lines with additional stabilization and APU system

    Directory of Open Access Journals (Sweden)

    Rajić Tomislav D.

    2016-01-01

    Full Text Available This paper explains the algorithm for the longitudinal differential protection of transmission lines with automatic reclosing. Classic stabilization is not sufficient for avoiding of unnecessary operations caused by saturation of current transformer. This problem can occur during the fault plased outside of the protected zone of the transmission line. It is shown how unnecessary operation can occur during the outside fault whithout using of additional stabilization. The different types of faults were simulated and comparison of relay operations with and without additional stabilization is presented. The simulations were performed on the three-phase model of the transmission line formed by using of MATLAB/Simulink program.

  9. Molecular structure of canine LINE-1 elements in canine transmissible venereal tumor.

    Science.gov (United States)

    Choi, Y; Ishiguro, N; Shinagawa, M; Kim, C J; Okamoto, Y; Minami, S; Ogihara, K

    1999-02-01

    We determined the 4251-bp sequence of open reading frame 2 (ORF2) of canine LINE-1 retroposon that encodes 1275 amino acids. The truncated LINE-1 inserts associated with transmissible venereal tumor (TVT) of dogs contained the 1378-bp LINE-1 insert (TVT-LINE) flanked by 10-bp direct repeats upstream to c-myc gene. The TVT-LINE elements were composed of 416 bp inverse sequences homologous to the complementary strand of the LINE-1, a 5-bp deletion and 962-bp sequences homologous to the 3' region of the LINE-1.

  10. Metastable memristive lines for signal transmission and information processing applications.

    Science.gov (United States)

    Slipko, Valeriy A; Pershin, Yuriy V

    2017-04-01

    Traditional studies of memristive devices have mainly focused on their applications in nonvolatile information storage and information processing. Here, we demonstrate that the third fundamental component of information technologies-the transfer of information-can also be employed with memristive devices. For this purpose, we introduce a metastable memristive circuit. Combining metastable memristive circuits into a line, one obtains an architecture capable of transferring a signal edge from one space location to another. We emphasize that the suggested metastable memristive lines employ only resistive circuit components. Moreover, their networks (for example, Y-connected lines) have an information processing capability.

  11. A planar transmission-line sensor for measuring the microwave permittivity of liquid and semisolid biological materials

    Science.gov (United States)

    A planar transmission-line configuration for rapid, nondestructive, wideband permittivity measurements of liquid and semisolid materials at microwave frequencies is described. The transmission-line propagation constant of the proposed configuration is determined with the multiline technique from sca...

  12. Kafjord, Norway Transmission Line VLF Antenna Tests, 1979-1980.

    Science.gov (United States)

    1981-09-15

    load of the town of Andenes to be carried by an older 22 kV line. The tests of March 1978 were made on a very cold night when the electrical load was...high and as a consequence the line voltage dropped approximately 20% throughout Andenes and *1 9 nearby towns. The lowered voltage is believed to...have caused some appliance damage in Andenes . No difficulties of any kind were reported related to the local telephone system. The temporary assignment

  13. Capacitive Coupling in Double-Circuit Transmission Lines

    Directory of Open Access Journals (Sweden)

    Zdenka Benesova

    2004-01-01

    Full Text Available The paper describes an algorithm for calculation of capacitances and charges on conductors in systems with earth wires and in double-circuit overhead lines with respect to phase arrangement. A balanced voltage system is considered. A suitable transposition of individual conductors enables to reduce the electric and magnetic fields in vicinity of overhead lines and to limit the inductive and capacitive linkage. The procedure is illustrated on examples the results of which lead to particular recommendations for designers.

  14. A distributed parameter model of transmission line transformer for high voltage nanosecond pulse generation.

    Science.gov (United States)

    Li, Jiangtao; Zhao, Zheng; Li, Longjie; He, Jiaxin; Li, Chenjie; Wang, Yifeng; Su, Can

    2017-09-01

    A transmission line transformer has potential advantages for nanosecond pulse generation including excellent frequency response and no leakage inductance. The wave propagation process in a secondary mode line is indispensable due to an obvious inside transient electromagnetic transition in this scenario. The equivalent model of the transmission line transformer is crucial for predicting the output waveform and evaluating the effects of magnetic cores on output performance. However, traditional lumped parameter models are not sufficient for nanosecond pulse generation due to the natural neglect of wave propagations in secondary mode lines based on a lumped parameter assumption. In this paper, a distributed parameter model of transmission line transformer was established to investigate wave propagation in the secondary mode line and its influential factors through theoretical analysis and experimental verification. The wave propagation discontinuity in the secondary mode line induced by magnetic cores is emphasized. Characteristics of the magnetic core under a nanosecond pulse were obtained by experiments. Distribution and formation of the secondary mode current were determined for revealing essential wave propagation processes in secondary mode lines. The output waveform and efficiency were found to be affected dramatically by wave propagation discontinuity in secondary mode lines induced by magnetic cores. The proposed distributed parameter model was proved more suitable for nanosecond pulse generation in aspects of secondary mode current, output efficiency, and output waveform. In depth, comprehension of underlying mechanisms and a broader view of the working principle of the transmission line transformer for nanosecond pulse generation can be obtained through this research.

  15. A distributed parameter model of transmission line transformer for high voltage nanosecond pulse generation

    Science.gov (United States)

    Li, Jiangtao; Zhao, Zheng; Li, Longjie; He, Jiaxin; Li, Chenjie; Wang, Yifeng; Su, Can

    2017-09-01

    A transmission line transformer has potential advantages for nanosecond pulse generation including excellent frequency response and no leakage inductance. The wave propagation process in a secondary mode line is indispensable due to an obvious inside transient electromagnetic transition in this scenario. The equivalent model of the transmission line transformer is crucial for predicting the output waveform and evaluating the effects of magnetic cores on output performance. However, traditional lumped parameter models are not sufficient for nanosecond pulse generation due to the natural neglect of wave propagations in secondary mode lines based on a lumped parameter assumption. In this paper, a distributed parameter model of transmission line transformer was established to investigate wave propagation in the secondary mode line and its influential factors through theoretical analysis and experimental verification. The wave propagation discontinuity in the secondary mode line induced by magnetic cores is emphasized. Characteristics of the magnetic core under a nanosecond pulse were obtained by experiments. Distribution and formation of the secondary mode current were determined for revealing essential wave propagation processes in secondary mode lines. The output waveform and efficiency were found to be affected dramatically by wave propagation discontinuity in secondary mode lines induced by magnetic cores. The proposed distributed parameter model was proved more suitable for nanosecond pulse generation in aspects of secondary mode current, output efficiency, and output waveform. In depth, comprehension of underlying mechanisms and a broader view of the working principle of the transmission line transformer for nanosecond pulse generation can be obtained through this research.

  16. MIDOT: A novel probe for monitoring high-current flat transmission lines.

    Science.gov (United States)

    Omar, K; Novac, B M; Graneau, N; Senior, P; Smith, I R; Sinclair, M

    2016-12-01

    A novel inductive probe, termed MIDOT, was developed for monitoring high-current flat transmission lines. While being inexpensive the probe does not require calibration, is resistant to both shock waves and temperature variations, and it is easy to manufacture and mount. It generates strong output signals that are relatively easy to interpret and has a detection region limited to a pre-defined part of the transmission line. The theoretical background related to the MIDOT probes, together with their practical implementation in both preliminary experimentation and high-current tests, is also presented in the paper. The novel probe can be used to benchmark existing 2D numerical codes used in calculating the current distribution inside the conductors of a transmission line but can also easily detect an early movement of a transmission line component. The probe can also find other applications, such as locating the position of a pulsed current flowing through a thin wire.

  17. The wave phase velocity in superconducting transmission lines near T{sub c}

    Energy Technology Data Exchange (ETDEWEB)

    Kuzhakhmetov, A.R.; Lobov, G.D.; Shtykov, V.V.; Zhgoon, S.A. [Moscow Power Engineering Inst. (Russian Federation). Radio Engineering Dept.

    1998-06-01

    A peculiarity in behavior of electromagnetic waves phase velocity ({nu}{sub ph}), propagating in superconducting planar transmission lines, in the vicinity of the transition temperature (T{sub c}) was observed in experiment and deduced theoretically. (orig.) 5 refs.

  18. Frequency and Transient Characteristics of MMIC Transmission Lines, Circuits and Antennas

    National Research Council Canada - National Science Library

    Balanis, Constantine A., 1938

    1997-01-01

    ...) and Method of Moments / Spectral Domain Approach (MoM/SDA). For the two dimensional planar transmission lines the propagation characteristics examined included the effective dielectric constant, attenuation constant, and characteristic impedance...

  19. Mathematical models of lightning-induced voltages in transmission lines in a permafrost region

    Science.gov (United States)

    Grigor'ev, Yuri M.; Borisova, Marpha N.; Longinova, Viktoriya Ya.; Ivanova, Anna A.

    2017-11-01

    Lightning induced voltages in transmission lines consist of electromagnetic and electrostatic components. The electrostatic component is much less than electromagnetic one in regions where soils have a high electrical conductivity. In this paper we present mathematical models of the electrostatic component of lightning induced voltages in transmissions lines in a permafrost region where soils have a low electrical conductivity. Numerical simulations show that the values of the electrostatic component is comparable to electromagnetic one in a permafrost region.

  20. Frequency selective properties of coaxial transmission lines loaded with combined artificial inclusions.

    Science.gov (United States)

    Falcone, Francisco; Gil, Javier

    2014-01-01

    The properties of a modified coaxial transmission line by periodic inclusions will be discussed. The introduction of split ring resonators, conductor stubs, air gaps, and combination of these gives rise to new frequency selective properties, such as stopband or passband behavior, observable in planar as well as volumetric metamaterial structures. These results envisage new potential applications and implementation of devices in coaxial transmission line technology.

  1. Frequency Selective Properties of Coaxial Transmission Lines Loaded with Combined Artificial Inclusions

    Directory of Open Access Journals (Sweden)

    Francisco Falcone

    2014-01-01

    Full Text Available The properties of a modified coaxial transmission line by periodic inclusions will be discussed. The introduction of split ring resonators, conductor stubs, air gaps, and combination of these gives rise to new frequency selective properties, such as stopband or passband behavior, observable in planar as well as volumetric metamaterial structures. These results envisage new potential applications and implementation of devices in coaxial transmission line technology.

  2. Review and Latest Trends in Mobile Robots Used on Power Transmission Lines

    OpenAIRE

    Rogério Sales Gonçalves; João Carlos Mendes Carvalho

    2013-01-01

    This paper presents the current state of the art in mobile robots used on power transmission lines. Many theoretical and experimental studies have been conducted in order to develop autonomous machines to travel along transmission lines to perform inspection and/or repair work. These machines can improve efficiency, reduce labour costs and are expected to reduce the risk of injury to maintenance personnel. Despite there already being a number of pieces of theoretical research and technologica...

  3. A Novel Design of Radio Frequency Energy Relays on Power Transmission Lines

    OpenAIRE

    Jin Tong; Yigang He; Bing Li; Fangming Deng; Tao Wang

    2016-01-01

    In this paper, we investigate the energy problem of monitoring sensors on high-voltage power transmission lines and propose a wireless charging scheme for a Radio Frequency IDentification (RFID) sensor tag to solve a commercial efficiency problem: the maintenance-caused power outage. Considering the environmental influences on power transmission lines, a self-powered wireless energy relay is designed to meet the energy requirement of the passive RFID sensor tag. The relay can obtain the elect...

  4. Multisection transmission line scatter function theory for measurements of soil dielectric properties

    Science.gov (United States)

    Vector network analyzers measure both reflection (S11) and transmission (S21) functions, but S21 has not been used to estimate soil dielectric permittivity independently. The objectives of this study were to: (1) derive the mathematical model for S21 of a multisection transmission line, and (2) tes...

  5. 77 FR 41369 - Dairyland Power Cooperative: CapX 2020 Hampton-Rochester-La Crosse Transmission Line Project

    Science.gov (United States)

    2012-07-13

    ... in the construction of a proposed 345-kilovolt (kV) transmission line and associated infrastructure... the proposed project, which, in addition to the 345-kV transmission line and associated infrastructure, includes 161-kV transmission lines in the vicinity of Rochester, Minnesota; construction of two new and...

  6. 77 FR 64333 - Relocation of Transmission Lines for the U.S. 93 Boulder City Bypass Project, Boulder County, NV...

    Science.gov (United States)

    2012-10-19

    ... Area Power Administration Relocation of Transmission Lines for the U.S. 93 Boulder City Bypass Project... and rebuilding approximately one mile of the Henderson-Mead 230-kilovolt (kV) transmission lines... installing new structures, conductors, overhead ground wire, insulators, and transmission line hardware. The...

  7. 75 FR 32940 - Request for Proposals for New or Upgraded Transmission Line Projects Under Section 1222 of the...

    Science.gov (United States)

    2010-06-10

    ... Transmission Line Projects Under Section 1222 of the Energy Policy Act of 2005 AGENCY: Southwestern Power... construction of new transmission lines in the states in which either PMA operates. DATES: Project Proposals... several states. Southwestern operates and maintains 1,380 miles of high voltage transmission lines in...

  8. 75 FR 75170 - Minnkota Power Cooperative, Inc.: Bemidji to Grand Rapids 230 kV Transmission Line Project

    Science.gov (United States)

    2010-12-02

    ... to Grand Rapids 230 kV Transmission Line Project (Project) in Beltrami, Hubbard, Itasca, and Cass... construct the 230 kilovolt (kV) transmission line between the Wilton Substation near Bemidji, Minnesota and... . ] SUPPLEMENTARY INFORMATION: Minnkota's proposed Project is to construct a 230 kilovolt (kV) transmission line...

  9. On the Relation between Composite Right-/Left-Handed Transmission Lines and Chebyshev Filters

    Directory of Open Access Journals (Sweden)

    Changjun Liu

    2009-01-01

    Full Text Available Composite right-/left-handed (CRLH transmission lines have gained great interest in the microwave community. In practical applications, such CRLH sections realized by series and shunt resonators have a finite length. Starting from the observation that a high-order Chebyshev filter also exhibits a periodic central section of very similar structure, the relations between finite length CRHL transmission lines and Chebyshev filters are discussed in this paper. It is shown that a finite length CRLH transmission line in the balanced case is equivalent to the central part of a low-ripple high-order Chebyshev band-pass filter, and a dual-CRLH transmission line in the balanced case is equivalent to a low-ripple high-order Chebyshev band-stop filter. The nonperiodic end sections of a Chebyshev filter can be regarded as matching sections, thus leading to an even better amplitude and phase response. It is also shown that, equally to a CRHL transmission line, a Chebyshev filter exhibits negative phase velocity in part of its passband. As a consequence, an improved behavior of finite length CRLH transmission lines may be achieved adding matching sections based on filter theory; this is demonstrated by a simulation example.

  10. Analysis of Power Network for Line Reactance Variation to Improve Total Transmission Capacity

    Directory of Open Access Journals (Sweden)

    Ikram Ullah

    2016-11-01

    Full Text Available The increasing growth in power demand and the penetration of renewable distributed generations in competitive electricity market demands large and flexible capacity from the transmission grid to reduce transmission bottlenecks. The bottlenecks cause transmission congestion, reliability problems, restrict competition, and limit the maximum dispatch of low cost generations in the network. The electricity system requires efficient utilization of the current transmission capability to improve the Available Transfer Capability (ATC. To improve the ATC, power flow among the lines can be managed by using Flexible AC Transmission System (FACTS devices as power flow controllers, which alter the parameters of power lines. It is important to place FACTS devices on suitable lines to vary the reactance for improving Total Transmission Capacity (TTC of the network and provide flexibility in the power flow. In this paper a transmission network is analyzed based on line parameters variation to improve TTC of the interconnected system. Lines are selected for placing FACTS devices based on real power flow Performance Index (PI sensitivity factors. TTC is computed using the Repeated Power Flow (RPF method using the constraints of lines thermal limits, bus voltage limits and generator limits. The reactance of suitable lines, selected on the basis of PI sensitivity factors are changed to divert the power flow to other lines with enough transfer capacity available. The improvement of TTC using line reactance variation is demonstrated with three IEEE test systems with multi-area networks. The results show the variation of the selected lines’ reactance in improving TTC for all the test networks with defined contingency cases.

  11. Fresnel equations and transmission line analogues for diffraction gratings

    Energy Technology Data Exchange (ETDEWEB)

    Kaushik, S.

    1995-08-01

    A simple and intuitive formalism is presented to describe diffraction in multi-layered periodic structures. We use the well known results from scalar analysis (wave propagation in homogeneous layered media) and show that they can be generalized rather readily to vector problems such as diffraction analysis. Specifically, we derive: (1) generalized Fresnel equations appropriate for reflection and transmission from an infinitely thick grating, (2) a generalized Airy formula for thin-film to describe reflection and transmission of light through a lamellar grating and (3) a matrix propagation method akin to that used for multi-layer thin film analysis. The results developed here complement the recent work on R-matrix and S-matrix propagation algorithms that have been used in connection with modal and differential grating theories. These algorithms have proven to be numerically stable for calculating diffraction efficiencies from deep groove gratings. The formalism developed here expands upon the earlier literature by providing important details that are hitherto unavailable.

  12. Practical Aspects of the Transmission Line Stub Matching in Microstrip

    Directory of Open Access Journals (Sweden)

    S. Novak

    1997-06-01

    Full Text Available While designing microwave circuits with microstrip lines using open or shorted stubs for matching or realization of filters, the actual circuit can be substantially mismatched when the length of the open stub is below 30 degrees of electrical length, or shorted stub is over 60 degrees of electrical length. Realization of such stubs could lead to practical difficulties because the normal etching accuracy does not support the exact lengths required for such stubs.

  13. Stress transmission across grounding lines and marine ice sheet instability

    Science.gov (United States)

    Docquier, David; Nick, Faezeh M.; Perichon, Laura; Pattyn, Frank

    2010-05-01

    The stability of marine ice sheets is largely controlled by the dynamic behaviour of the grounding line, i.e., the contact of the bottom of the ice sheet resting on the bedrock with the ocean water. Marine ice sheet instability implies that an ice sheet on a downward sloping bedrock towards the interior will never find stable equilibria, hence leading to ice sheet collapse, unless an upward slope is reached (Schoof, 2007). The latter study shows that steady state solutions using a boundary layer theory for ice flux are in very close agreement with numerical resolutions that resolve the transition zone. However, the time dependent response of grounding line migration is not predicted by this theory. Precise knowledge of this response is essential for assessing the short term impact of accelerated ice discharge on sea level rise. Here we present the results of MISMIP-type (Marine Ice Sheet Model Intercomparison Project) experiments with different sets of numerical flowline models (fixed and moving grid) that solve the stress field in the transition zone according to different approximations to the Stokes equations. These models include shallow-ice (SIA0), shallow-shelf (L1L2) and higher-order (LMLa) approximations, and combinations of these types. All experiments are run at different spatial resolutions and for different sizes of the transition zone (high to low friction). The comparison of several stress approximants allows us to evaluate which stress components in the flow direction are important to the general behaviour of grounding line migration.

  14. Theoretical aspects of selection of optimal design parameters of a new generation of AC transmission lines

    Directory of Open Access Journals (Sweden)

    Postolati V.M.

    2010-04-01

    Full Text Available The problems of compactness and of a choice of optimal parameters of alternating current transmission lines are considered. Analytical analysis of some constructive characteristics of three variants of lines of new generation (one-chain, two-chain and operated self-compensated, for the purpose of their optimization by criteria of the maximum compactness is performed.

  15. Measuring the complex permittivity of poultry meat with a planar transmission-line sensor

    Science.gov (United States)

    A planar transmission-line sensor is used to measure the complex permittivity of chicken breast meat over the frequency range 0.5 – 5 GHz. Results for the permittivity of nine samples of chicken breast meat are compared to results obtained with a commercially available open-ended coaxial-line probe....

  16. submitter Superconducting transmission lines – Sustainable electric energy transfer with higher public acceptance?

    CERN Document Server

    Thomas, Heiko; Chervyakov, Alexander; Stückrad, Stefan; Salmieri, Delia; Rubbia, Carlo

    2016-01-01

    Despite the extensive research and development investments into superconducting science and technology, both at the fundamental and at the applied levels, many benefits of superconducting transmission lines (SCTL) remain unknown to the public and decision makers at large. This paper aims at informing about the progress in this important research field. Superconducting transmission lines have a tremendous size advantage and lower total electrical losses for high capacity transmission plus a number of technological advantages compared to solutions based on standard conductors. This leads to a minimized environmental impact and enables an overall more sustainable transmission of electric energy. One of the direct benefits may be an increased public acceptance due to the low visual impact with a subsequent reduction of approval time. The access of remote renewable energy (RE) sources with high-capacity transmission is rendered possible with superior efficiency. That not only translates into further reducing $CO_2...

  17. Research on the technology and economic calculation model of power transmission line considering environmental benefits

    Science.gov (United States)

    Liu, Wei; Wang, Tao; Liu, Yiqun; Sun, Chenjun; Zeng, Ming

    2017-01-01

    As an important part of the modern energy supply system, power grid has a very important influence on the regional energy system, especially in the context of large-scale development of new energy sources, cross transmission line planning is the key to optimize the energy supply system. First of all, this paper starts from the typical regional energy problem analysis, proposes the thought of relying on cross transmission to solve the problems of energy supply; Secondly, this paper analyzes the external environment and the effect of cross transmission, establishes the technical and economic model of transmission planning based on cost effectiveness; Finally, according to the example of China's energy system in Beijing, Tianjin, Hebei region, to carry out technical and economic analysis of transmission line technology, and give the relevant recommendations.

  18. Multiplex Superconducting Transmission Line for green power consolidation on a Smart Grid

    Science.gov (United States)

    McIntyre, P.; Gerity, J.; Kellams, J.; Sattarov, A.

    2017-12-01

    A multiplex superconducting transmission line (MSTL) is being developed for applications requiring interconnection of multi-MW electric power generation among a number of locations. MSTL consists of a cluster of many 2- or 3-conductor transmission lines within a coaxial cryostat envelope. Each line operates autonomously, so that the interconnection of multiple power loads can be done in a failure-tolerant network. Specifics of the electrical, mechanical, and cryogenic design are presented. The consolidation of transformation and conditioning and the failure-tolerant interconnects have the potential to offer important benefit for the green energy components of a Smart Grid.

  19. Computation of corona effects in transmission lines using state-space techniques

    Energy Technology Data Exchange (ETDEWEB)

    Herdem, Saadetdin [Nigde Univ., Dept. of Electrical and Electronics Engineering, Malatya (Turkey); Mamis, M. Salih [Inonu Univ., Dept. of Electrical and Electronics Engineering, Malatya (Turkey)

    2003-07-01

    In this paper, state-space method is applied to compute transients in power transmission lines by considering corona effects. Transmission line is modeled by lumped parameter identical sections to simulate the distribution nature of the line and nonlinear corona branches are combined with these sections. The whole system is composed of RLC elements, sources and switches. The response of the system is calculated using state-space method which has been developed for the analysis of nonlinear power electronic circuits with periodically operated switches. (Author)

  20. Transmission line design for a power distribution system at 20 kHz for aircraft

    Science.gov (United States)

    Zelby, L. W.; Mathes, J. B.; Shawver, J. W.

    1986-01-01

    A low inductance, low characteristic impedance transmission line was designed for a 20 kHz power distribution system. Several different conductor configurations were considered: strip lines, interdigitated metal ribbons, and standard insulated wires in multiwire configurations (circular and rectangular cylindrical arrangements). The final design was a rectangular arrangement of multiple wires of the same gauge with alternating polarities from wire to wire. This offered the lowest inductance per unit length (on the order of several nanohenries/meter) and the lowest characteristic impedance (on the order of one Ohm). Standard multipin connectors with gold-plated elements were recommended with this transmission line, the junction boxes to be internally connected with flat metal ribbons for low inductance, and the line to be constructed in sections of suitable length. Computer programs for the calculation of inductance of multiwire lines and of capacitances of strip lines were developed.

  1. External synchronization of oscillating pulse edge on a transmission line with regularly spaced tunnel diodes.

    Science.gov (United States)

    Narahara, Koichi; Misono, Masatoshi; Miyakawa, Kenji

    2013-01-01

    We investigate the external synchronization of the oscillating pulse edges developed in a transmission line periodically loaded with tunnel diodes (TDs), termed a TD line. It is observed that the pulse edge oscillates on a TD line when supplied by an appropriate voltage at the end of the line. We discuss how the pulse edge oscillates on a TD line and the properties of the external synchronization of the edge oscillation driven by a sinusoidal perturbation. By applying a phase-reduction scheme to the transmission equation of a TD line, we obtain the phase sensitivity, which satisfactory explains the measured spatial dependence of the locking range on the frequency. Moreover, we successfully detect the spatiotemporal behaviors of the edge oscillation by establishing synchronization with the sampling trigger of an oscilloscope.

  2. Arcing Faults Location Methods for Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    Mateusz Pustułka

    2014-03-01

    Full Text Available This paper presents three different fault location approaches: one-end Takagi algorithm, two-end algorithm considering natural fault loops and neural network. It is assumed that three-phase voltages and currents from both ends of the line measured asynchronously are the input signals of the fault locator. In addition to natural fault loop signals also the use of symmetrical components (positive and negative or incremental positive sequence components for fault location were considered. Results of the evaluation study have been included, analyzed and discussed. The impact of filtration has also been considered.

  3. Transmission Lines or Poles, Electric - VOLUSIA COUNTY MAJOR POWER LINES (Arcs)

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Volusia County Power Line data was aggregated by using parcel data and visual inspection of 2005 aerial photography to determine centerline of Power Lines Right of...

  4. Transmission line model for extraction of transmission characteristics in photonic crystal waveguides with stubs: optical filter design.

    Science.gov (United States)

    Khavasi, Amin; Miri, Mehdi; Rezaei, Mohsen; Mehrany, Khashayar; Rashidian, Bizhan

    2012-04-15

    A simple and efficient transmission line model is proposed here to study how the transmission characteristics of photonic crystal waveguides are tailored by introduction of stubs patterned in the photonic crystal lattice. It is shown that band-pass and band-stop optical filters can be easily designed and optimized when stubs of appropriate length are brought in. Since the lengths of the designed stubs are not necessarily integer multiples of the photonic crystal lattice constant, a geometric shift in a portion of the photonic crystal structure is shown to be essential. The proposed model is verified by using a rigorous numerical method. An excellent agreement is observed between the numerical results and the transmission characteristics as extracted by the proposed model. © 2012 Optical Society of America

  5. Fiber optic picosecond laser pulse transmission line for hydrogen ion beam longitudinal profile measurement.

    Science.gov (United States)

    Huang, Chunning; Liu, Yun; Aleksandrov, Alexander

    2013-07-01

    We present a fiber optic laser pulse transmission line for nonintrusive longitudinal profile measurement of the hydrogen ion (H(-)) beam at the front-end of the Spallation Neutron Source accelerator. The 80.5 MHz, 2.5 ps, multikilowatt optical pulses are delivered to the accelerator beam line through a large-mode-area polarization-maintaining optical fiber to ensure high measurement stability. The transmission efficiency, output laser beam quality, pulse jitter, and pulse width broadening over a 30 m long fiber line are experimentally investigated. A successful measurement of the H(-) beam microbunch (~130 ps) profile is obtained. The experiment is the first demonstration to our knowledge of particle beam profile diagnostics using a fiber optic laser pulse transmission line.

  6. Assessment of Fecundity and Germ Line Transmission in Two Transgenic Pig Lines Produced by Sleeping Beauty Transposition

    Science.gov (United States)

    Garrels, Wiebke; Holler, Stephanie; Cleve, Nicole; Niemann, Heiner; Ivics, Zoltan; Kues, Wilfried A.

    2012-01-01

    Recently, we described a simplified injection method for producing transgenic pigs using a non-autonomous Sleeping Beauty transposon system. The founder animals showed ubiquitous expression of the Venus fluorophore in almost all cell types. To assess, whether expression of the reporter fluorophore affects animal welfare or fecundity, we analyzed reproductive parameters of two founder boars, germ line transmission, and organ and cell specific transgene expression in animals of the F1 and F2 generation. Molecular analysis of ejaculated sperm cells suggested three monomeric integrations of the Venus transposon in both founders. To test germ line transmission of the three monomeric transposon integrations, wild-type sows were artificially inseminated. The offspring were nursed to sexual maturity and hemizygous lines were established. A clear segregation of the monomeric transposons following the Mendelian rules was observed in the F1 and F2 offspring. Apparently, almost all somatic cells, as well as oocytes and spermatozoa, expressed the Venus fluorophore at cell-type specific levels. No detrimental effects of Venus expression on animal health or fecundity were found. Importantly, all hemizygous lines expressed the fluorophore in comparable levels, and no case of transgene silencing or variegated expression was found after germ line transmission, suggesting that the insertions occurred at transcriptionally permissive loci. The results show that Sleeping Beauty transposase-catalyzed transposition is a promising approach for stable genetic modification of the pig genome. PMID:24705079

  7. Assessment of fecundity and germ line transmission in two transgenic pig lines produced by sleeping beauty transposition.

    Science.gov (United States)

    Garrels, Wiebke; Holler, Stephanie; Cleve, Nicole; Niemann, Heiner; Ivics, Zoltan; Kues, Wilfried A

    2012-10-12

    Recently, we described a simplified injection method for producing transgenic pigs using a non-autonomous Sleeping Beauty transposon system. The founder animals showed ubiquitous expression of the Venus fluorophore in almost all cell types. To assess, whether expression of the reporter fluorophore affects animal welfare or fecundity, we analyzed reproductive parameters of two founder boars, germ line transmission, and organ and cell specific transgene expression in animals of the F1 and F2 generation. Molecular analysis of ejaculated sperm cells suggested three monomeric integrations of the Venus transposon in both founders. To test germ line transmission of the three monomeric transposon integrations, wild-type sows were artificially inseminated. The offspring were nursed to sexual maturity and hemizygous lines were established. A clear segregation of the monomeric transposons following the Mendelian rules was observed in the F1 and F2 offspring. Apparently, almost all somatic cells, as well as oocytes and spermatozoa, expressed the Venus fluorophore at cell-type specific levels. No detrimental effects of Venus expression on animal health or fecundity were found. Importantly, all hemizygous lines expressed the fluorophore in comparable levels, and no case of transgene silencing or variegated expression was found after germ line transmission, suggesting that the insertions occurred at transcriptionally permissive loci. The results show that Sleeping Beauty transposase-catalyzed transposition is a promising approach for stable genetic modification of the pig genome.

  8. About the Coupling Factor Influence on the Ground Fault Current Distribution on Overhead Transmission Lines

    Directory of Open Access Journals (Sweden)

    VINTAN, M.

    2010-05-01

    Full Text Available A phase-to-ground fault occurring on a transmission line divides the line into two sections, each extending from the fault towards one end of the line. These two sections of the line may be considered infinite if some certain conditions are met; otherwise, they must be regarded as finite. This paper treats the case when those two sections of the line are both very long and allows the determination of the ground fault current distribution in power networks. The influence of the coupling factor between the faulted phase and the ground wire on the ground fault current distribution is studied.

  9. About the Coupling Factor Influence on the Ground Fault Current Distribution on Overhead Transmission Lines

    OpenAIRE

    VINTAN, M.

    2010-01-01

    A phase-to-ground fault occurring on a transmission line divides the line into two sections, each extending from the fault towards one end of the line. These two sections of the line may be considered infinite if some certain conditions are met; otherwise, they must be regarded as finite. This paper treats the case when those two sections of the line are both very long and allows the determination of the ground fault current distribution in power networks. The influence of the coupling f...

  10. Analysis of transmission lines loaded with pairs of coupled resonant elements and application to sensors

    Energy Technology Data Exchange (ETDEWEB)

    Naqui, J.; Su, L., E-mail: lijuan.suri.su@gmail.com; Mata, J.; Martín, F., E-mail: Ferran.Martin@uab.es

    2015-06-01

    This paper is focused on the analysis of transmission lines loaded with pairs of magnetically coupled resonators. We have considered two different structures: (i) a microstrip line loaded with pairs of stepped impedance resonators (SIRs), and (ii) a coplanar waveguide (CPW) transmission line loaded with pairs of split ring resonators (SRRs). In both cases, the line exhibits a single resonance frequency (transmission zero) if the resonators are identical (symmetric structure with regard to the line axis), and this resonance is different to the one of the line loaded with a single resonator due to inter-resonator coupling. If the structures are asymmetric, inter-resonator coupling enhances the distance between the two split resonance frequencies that arise. In spite that the considered lines and loading resonators are very different and are described by different lumped element equivalent circuit models, the phenomenology associated to the effects of coupling is exactly the same, and the resonance frequencies are given by identical expressions. The reported lumped element circuit models of both structures are validated by comparing the circuit simulations with extracted parameters with both electromagnetic simulations and experimental data. These structures can be useful for the implementation of microwave sensors based on symmetry properties. - Highlights: • Magnetic-coupling between resonant elements affects transmission properties. • Inter-resonant coupling enhances the distance of two resonant frequencies. • The structures are useful for sensors and comparators, etc.

  11. Nanoscale broadband transmission lines for spin qubit control.

    Science.gov (United States)

    Dehollain, J P; Pla, J J; Siew, E; Tan, K Y; Dzurak, A S; Morello, A

    2013-01-11

    The intense interest in spin-based quantum information processing has caused an increasing overlap between the two traditionally distinct disciplines of magnetic resonance and nanotechnology. In this work we discuss rigorous design guidelines to integrate microwave circuits with charge-sensitive nanostructures, and describe how to simulate such structures accurately and efficiently. We present a new design for an on-chip, broadband, nanoscale microwave line that optimizes the magnetic field used to drive a spin-based quantum bit (or qubit) while minimizing the disturbance to a nearby charge sensor. This new structure was successfully employed in a single-spin qubit experiment, and shows that the simulations accurately predict the magnetic field values even at frequencies as high as 30 GHz.

  12. Predictive Models of Current, Voltage, and Power Losses on Electric Transmission Lines

    Directory of Open Access Journals (Sweden)

    O. M. Bamigbola

    2014-01-01

    Full Text Available A modern and civilized society is so much dependent on the use of electrical energy because it has been the most powerful vehicle for facilitating economic, industrial, and social developments. Electrical energy produced at power stations is transmitted to load centres from where it is distributed to its consumers through the use of transmission lines run from one place to another. As a result of the physical properties of the transmission medium, some of the transmitted power is lost to the surroundings. The overall effect of power losses on the system is a reduction in the quantity of power available to the consumers. An accurate knowledge of transmission losses is hinged on the ability to correctly predict the available current and voltage along transmission lines. Therefore, mathematical physics expressions depicting the evolution of current and voltage on a typical transmission line were formulated, and derived therefrom were models to predict available current and voltage, respectively, at any point on the transmission line. The predictive models evolved as explicit expressions of the space variable and they are in close agreement with empirical data and reality.

  13. Marys Lake 69/115-kV transmission line upgrade and substation expansion projects

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park.

  14. The relationship between residential proximity to extremely low frequency power transmission lines and adverse birth outcomes.

    Science.gov (United States)

    Auger, Nathalie; Joseph, Dominique; Goneau, Marc; Daniel, Mark

    2011-01-01

    Occupational exposure to electromagnetic fields has been linked to adverse birth outcomes. This study evaluated whether maternal residential proximity to power transmission lines was associated with adverse birth outcomes. Live singleton births in the Montréal and Québec census metropolitan areas from 1990 to 2004 were extracted from the Québec birth file (N=707,215). Proximity was defined as residing within 400 m of a transmission line. Generalised estimating equations were used to evaluate associations between residential proximity to transmission lines and preterm birth (PTB), low birth weight (LBW), small-for-gestational age (SGA) birth and infant sex, accounting for maternal age, education, marital status, ethnicity, parity, period of birth, and neighbourhood median household income. There was no association between residential proximity to transmission lines and PTB, LBW and infant sex in unadjusted and adjusted models. A lower likelihood of SGA birth was present for some distance categories (eg, adjusted OR 0.88, 95% CI 0.81 to 0.95 for 50-75 m relative to ≥400 m). Residential proximity to transmission lines is not associated with adverse births outcomes.

  15. Study of transmission line attenuation in broad band millimeter wave frequency range

    Energy Technology Data Exchange (ETDEWEB)

    Pandya, Hitesh Kumar B. [ITER-India, IPR, Gandhinagar, Gujarat (India); Austin, M. E. [Institute for Fusion Studies, the University of Texas at Austin, Austin, Texas (United States); Ellis, R. F. [Laboratory for Plasma and Fusion Energy Studies, University of Maryland, College Park, Maryland 20742 (United States)

    2013-10-15

    Broad band millimeter wave transmission lines are used in fusion plasma diagnostics such as electron cyclotron emission (ECE), electron cyclotron absorption, reflectometry and interferometry systems. In particular, the ECE diagnostic for ITER will require efficient transmission over an ultra wide band, 100 to 1000 GHz. A circular corrugated waveguide transmission line is a prospective candidate to transmit such wide band with low attenuation. To evaluate this system, experiments of transmission line attenuation were performed and compared with theoretical loss calculations. A millimeter wave Michelson interferometer and a liquid nitrogen black body source are used to perform all the experiments. Atmospheric water vapor lines and continuum absorption within this band are reported. Ohmic attenuation in corrugated waveguide is very low; however, there is Bragg scattering and higher order mode conversion that can cause significant attenuation in this transmission line. The attenuation due to miter bends, gaps, joints, and curvature are estimated. The measured attenuation of 15 m length with seven miter bends and eighteen joints is 1 dB at low frequency (300 GHz) and 10 dB at high frequency (900 GHz), respectively.

  16. Study of transmission line attenuation in broad band millimeter wave frequency range.

    Science.gov (United States)

    Pandya, Hitesh Kumar B; Austin, M E; Ellis, R F

    2013-10-01

    Broad band millimeter wave transmission lines are used in fusion plasma diagnostics such as electron cyclotron emission (ECE), electron cyclotron absorption, reflectometry and interferometry systems. In particular, the ECE diagnostic for ITER will require efficient transmission over an ultra wide band, 100 to 1000 GHz. A circular corrugated waveguide transmission line is a prospective candidate to transmit such wide band with low attenuation. To evaluate this system, experiments of transmission line attenuation were performed and compared with theoretical loss calculations. A millimeter wave Michelson interferometer and a liquid nitrogen black body source are used to perform all the experiments. Atmospheric water vapor lines and continuum absorption within this band are reported. Ohmic attenuation in corrugated waveguide is very low; however, there is Bragg scattering and higher order mode conversion that can cause significant attenuation in this transmission line. The attenuation due to miter bends, gaps, joints, and curvature are estimated. The measured attenuation of 15 m length with seven miter bends and eighteen joints is 1 dB at low frequency (300 GHz) and 10 dB at high frequency (900 GHz), respectively.

  17. Electromagnetic Field Interference on Transmission Lines due to On-Board Antenna

    Directory of Open Access Journals (Sweden)

    Heekwon Lee

    2015-01-01

    Full Text Available As the available space in the board of a mobile device becomes smaller and more compact, circuit elements and transmission lines are arranged in very close proximity, especially from the antennas which are usually installed on the same board. Due to the various on-board antennas which are designed in small space, the transmission lines on the board are electromagnetically interfered, resulting in the performance degradation of the circuit. So the engineers and circuit designers should find the least interfered place for the transmission lines and components to minimize the electromagnetic interferences. This paper discusses and presents a methodology to find the least sensitive position in the induced current distribution as well as in the noise power delivered from the antenna. For this purpose some vertical, horizontal, and bent transmission lines with antenna on the same board are designed and fabricated with and without common ground, and the transferred powers to the transmission lines were measured and were also simulated using a full-wave simulator. The results predicted by the EM simulation model were successfully confirmed through the measurement of S-parameters in the experimental setup, which shows the validness of the suggested analysis method.

  18. Applications of Multiconductor Transmission Line Theory to the Prediction of Cable Coupling. Volume I. Multiconductor Transmission Line Theory.

    Science.gov (United States)

    1976-04-01

    line theory on which the remaining volumen will be based. The remaining volumes will investigate the application of this theory to specific classes...functions with magnitudes greater than unity in antenna-to-antenna inter- ference coupling problems and this illustrates the importance of considering the...the form in (65) are [5, 52, 65] where a complex number c with magnitude c and angle 0 m is written as I:. •T is unitary such that T- = T* an "yclic

  19. Dynamic Responses and Vibration Control of the Transmission Tower-Line System: A State-of-the-Art Review

    Science.gov (United States)

    Chen, Bo; Guo, Wei-hua; Li, Peng-yun; Xie, Wen-ping

    2014-01-01

    This paper presented an overview on the dynamic analysis and control of the transmission tower-line system in the past forty years. The challenges and future developing trends in the dynamic analysis and mitigation of the transmission tower-line system under dynamic excitations are also put forward. It also reviews the analytical models and approaches of the transmission tower, transmission lines, and transmission tower-line systems, respectively, which contain the theoretical model, finite element (FE) model and the equivalent model; shows the advances in wind responses of the transmission tower-line system, which contains the dynamic effects under common wind loading, tornado, downburst, and typhoon; and discusses the dynamic responses under earthquake and ice loads, respectively. The vibration control of the transmission tower-line system is also reviewed, which includes the magnetorheological dampers, friction dampers, tuned mass dampers, and pounding tuned mass dampers. PMID:25105161

  20. Dynamic responses and vibration control of the transmission tower-line system: a state-of-the-art review.

    Science.gov (United States)

    Chen, Bo; Guo, Wei-hua; Li, Peng-yun; Xie, Wen-ping

    2014-01-01

    This paper presented an overview on the dynamic analysis and control of the transmission tower-line system in the past forty years. The challenges and future developing trends in the dynamic analysis and mitigation of the transmission tower-line system under dynamic excitations are also put forward. It also reviews the analytical models and approaches of the transmission tower, transmission lines, and transmission tower-line systems, respectively, which contain the theoretical model, finite element (FE) model and the equivalent model; shows the advances in wind responses of the transmission tower-line system, which contains the dynamic effects under common wind loading, tornado, downburst, and typhoon; and discusses the dynamic responses under earthquake and ice loads, respectively. The vibration control of the transmission tower-line system is also reviewed, which includes the magnetorheological dampers, friction dampers, tuned mass dampers, and pounding tuned mass dampers.

  1. Coupling and corona effects research plan for transmission lines. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bridges, J E; Formanek, V C

    1976-06-01

    Concern has arisen over the possible effects of electric and magnetic fields produced by EHV-UHV transmission lines. Past and ongoing research concerning the electric and magnetic field effects from EHV-UHV transmission lines was reviewed as it pertains to the following areas: (1) electromagnetic interference, (2) acoustic noise, (3) generation of gaseous effluents, and (4) safety considerations of induced voltages and currents. The intent of this review was to identify the short and long range research projects required to address these areas. The research plan identifies and gives priority to twenty programs in corona and coupling effects. In the case of the corona effects, a number of programs were recommended for acoustic noise and electromagnetic interference to delineate improved power line design criteria in terms of social, meteorological, geographical and cost constraints. Only one project is recommended in the case of ozone generation, because the results of comprehensive analyses, laboratory studies and field measurements have demonstrated that power lines do not contribute significant quantities of ozone. In the case of the coupling effects, a number of programs are recommended for HVAC transmission lines to improve the theoretically developed design guidelines by considering practical constraints. For HVDC transmission lines, programs are suggested to engender a better theoretical understanding and practical measurements capability for the coupling mechanisms of the dc electric and magnetic field with nearby objects. The interrelationship of the programs and their role in a long-term research plan is also discussed.

  2. Research on Poppers Used as Electrical Connectors in High Speed Textile Transmission Lines

    Directory of Open Access Journals (Sweden)

    Leśnikowski Jacek

    2016-12-01

    Full Text Available This paper presents results of research on poppers used as electrical connectors connecting fragments of textile signal lines. These lines can be used in intelligent clothing for connecting electronic modules implemented in it. Intelligent (smart clothing can be used, among others, in the health monitoring of the elderly, newborn babies, or people working in hazardous conditions, for example, firefighters and soldiers. The aim of the present study was to examine the usefulness of poppers, widely used in clothing, as electrical connectors connecting parts of the textile signal lines designed for transmission of high-speed digital signals. The paper presents examples of measured parameters characterizing transmission properties of two fragments of the coplanar, textile transmission line connected to each other using conventional poppers. The presented measurement results contain the so-called s parameters, characteristic impedance of the poppers, and eye measurements characterizing distortions of digital signals passing through the tested line. In the article, the effect of temperature and humidity of air surrounding the tested poppers on their characteristic impedance was also presented. This property and its stability are important in signal lines designed for high-speed data transmission.

  3. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-106)SnoKing Tap to Monroe-Samamish Line

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Mark A. [Bonneville Power Administration, Portland, OR (United States)

    2002-09-30

    Vegetation Management along the SnoKing Tap to the Monroe-Samamish transmission line from structure 8/1 through structure 20/6. BPA proposes to remove unwanted vegetation along the right-of-way, access roads and around tower structures along the subject transmission line corridor. The right-of-way will be treated using selective and non-selective methods that include hand cutting, mowing and herbicide treatments. Approximately 12 miles of access roads will be cleared using selective and non-selective methods that include hand cutting, mowing and herbicide treatments. Approximately 65 tower sites will be treated using selective and non-selective methods that include hand cutting, mowing and herbicide treatments. Vegetation management is required for unimpeded operation and maintenance of the subject transmission line. See Section 1of the attached checklist for a complete description of the proposal.

  4. A new shielding effectiveness measurement method based on a skin-effect transmission line coupler

    Directory of Open Access Journals (Sweden)

    T. Kleine-Ostmann

    2007-06-01

    Full Text Available We propose a new convenient material shielding effectiveness measurement method based on a skin-effect transmission line coupler. The method is somewhat similar to the arrangement with two coupled TEM cells known from literature. The transmission line coupler consists of a pair of identical transmission line 2-port devices. Each device contains a coaxial waveguide, with a circular inner conductor and an outer conductor having a square cross section. One side of the outer conductor is left completely open as a slot. The slot is surrounded by a large metal housing to contact the two halves. As a measure for the shielding effectiveness the coupling between the two devices is measured in terms of scattering parameters after the test material is brought between the two halves. The devices can be used in a range from low frequencies to a few GHz.

  5. Transmission Line Jobs and Economic Development Impact (JEDI) Model User Reference Guide

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, M.; Keyser, D.

    2013-10-01

    The Jobs and Economic Development Impact (JEDI) models, developed through the National Renewable Energy Laboratory (NREL), are freely available, user-friendly tools that estimate the potential economic impacts of constructing and operating power generation projects for a range of conventional and renewable energy technologies. The Transmission Line JEDI model can be used to field questions about the economic impacts of transmission lines in a given state, region, or local community. This Transmission Line JEDI User Reference Guide was developed to provide basic instruction on operating the model and understanding the results. This guide also provides information on the model's underlying methodology, as well as the parameters and references used to develop the cost data contained in the model.

  6. Kinetic inductance driven nanoscale 2D and 3D THz transmission lines.

    Science.gov (United States)

    Mousavi, S Hossein; Williamson, Ian A D; Wang, Zheng

    2016-05-03

    We examine the unusual dispersion and attenuation of transverse electromagnetic waves in the few-THz regime on nanoscale graphene and copper transmission lines. Conventionally, such propagation has been considered to be highly dispersive, due to the RC time constant-driven voltage diffusion below 1 THz and plasmonic effects at higher optical frequencies. Our numerical modeling across the microwave, THz, and optical frequency ranges reveals that the conductor kinetic inductance creates an ultra-broadband linear-dispersion and constant-attenuation region in the THz regime. This so-called LC region is an ideal characteristic that is known to be absent in macro-scale transmission lines. The kinetic-LC frequency range is dictated by the structural dimensionality and the free-carrier scattering rate of the conductor material. Moreover, up to 40x wavelength reduction is observed in graphene transmission lines.

  7. Analysis of the transients on the multi-circuit overhead transmission line

    Science.gov (United States)

    Nazarčík, Tomáš; Benešová, Zdeňka

    2017-11-01

    In this paper a method for a transient analysis on the multi-circuit overhead transmission line with different voltage levels (EHV and HV) is presented. The influence of inductive and capacitive couplings between the parallel circuits placed on the same tower is studied. The transmission line model consists of mutual coupled two-port cascades which can be described by a system of ordinary differential equations (ODE). This system has been solved numerically in MATLAB, the obtained results provide the time distribution of currents and voltages in all conductors along the transmission line. The presented algorithm allows solving various types of transients which can occur during switching off- and on-operations, shortcircuits etc.

  8. Broadband parametric amplifiers based on nonlinear kinetic inductance artificial transmission lines

    Science.gov (United States)

    Chaudhuri, S.; Li, D.; Irwin, K. D.; Bockstiegel, C.; Hubmayr, J.; Ullom, J. N.; Vissers, M. R.; Gao, J.

    2017-04-01

    We present broadband parametric amplifiers based on the kinetic inductance of superconducting NbTiN thin films in an artificial (lumped-element) transmission line architecture. We demonstrate two amplifier designs implementing different phase matching techniques: periodic impedance loading and resonator phase shifters placed periodically along the transmission line. Our design offers several advantages over previous CPW-based amplifiers, including intrinsic 50 Ω characteristic impedance, natural suppression of higher pump harmonics, lower required pump power, and shorter total trace length. Experimental realizations of both versions of the amplifiers are demonstrated. With a transmission line length of 20 cm, we have achieved gains of 15 dB over several GHz of bandwidth.

  9. Non-Linear Transmission Line (NLTL) Microwave Source Lecture Notes the United States Particle Accelerator School

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Steven J. [Los Alamos National Laboratory; Carlsten, Bruce E. [Los Alamos National Laboratory

    2012-06-26

    We will quickly go through the history of the non-linear transmission lines (NLTLs). We will describe how they work, how they are modeled and how they are designed. Note that the field of high power, NLTL microwave sources is still under development, so this is just a snap shot of their current state. Topics discussed are: (1) Introduction to solitons and the KdV equation; (2) The lumped element non-linear transmission line; (3) Solution of the KdV equation; (4) Non-linear transmission lines at microwave frequencies; (5) Numerical methods for NLTL analysis; (6) Unipolar versus bipolar input; (7) High power NLTL pioneers; (8) Resistive versus reactive load; (9) Non-lineaer dielectrics; and (10) Effect of losses.

  10. Transmission line effects on the coil noise correlation matrix in MRI.

    Science.gov (United States)

    Brown, Ryan; Wang, Yi

    2008-01-01

    Noise correlation is an important topic in radiofrequency (RF) coil design for magnetic resonance imaging (MRI). The original noise correlation formula derived by Redpath showed correlation depends on the real part of the inverse impedance matrix. In this work, we introduce a more generalized formula to include effects from transmission lines and preamplifier input impedance mismatch. This formula is used to calculate correlation between two-channel circuits connected to preamplifiers using transmission lines of variable electrical length. The calculated correlation matches well with that measured on the MR scanner and suggests transmission line length can be utilized as an additional degree of freedom for coil decoupling, and can be adjusted to achieve zero noise correlation.

  11. Low-Loss Transmission Lines for High-Power Terahertz Radiation.

    Science.gov (United States)

    Nanni, Emilio A; Jawla, Sudheer K; Shapiro, Michael A; Woskov, Paul P; Temkin, Richard J

    2012-07-01

    Applications of high-power Terahertz (THz) sources require low-loss transmission lines to minimize loss, prevent overheating and preserve the purity of the transmission mode. Concepts for THz transmission lines are reviewed with special emphasis on overmoded, metallic, corrugated transmission lines. Using the fundamental HE(11) mode, these transmission lines have been successfully implemented with very low-loss at high average power levels on plasma heating experiments and THz dynamic nuclear polarization (DNP) nuclear magnetic resonance (NMR) experiments. Loss in these lines occurs directly, due to ohmic loss in the fundamental mode, and indirectly, due to mode conversion into high order modes whose ohmic loss increases as the square of the mode index. An analytic expression is derived for ohmic loss in the modes of a corrugated, metallic waveguide, including loss on both the waveguide inner surfaces and grooves. Simulations of loss with the numerical code HFSS are in good agreement with the analytic expression. Experimental tests were conducted to determine the loss of the HE(11) mode in a 19 mm diameter, helically-tapped, three meter long brass waveguide with a design frequency of 330 GHz. The measured loss at 250 GHz was 0.029 ± 0.009 dB/m using a vector network analyzer approach and 0.047 ± 0.01 dB/m using a radiometer. The experimental results are in reasonable agreement with theory. These values of loss, amounting to about 1% or less per meter, are acceptable for the DNP NMR application. Loss in a practical transmission line may be much higher than the loss calculated for the HE(11) mode due to mode conversion to higher order modes caused by waveguide imperfections or miter bends.

  12. Simple Correctors for Elimination of High-Order Modes in Corrugated Waveguide Transmission Lines.

    Science.gov (United States)

    Kowalski, Elizabeth J; Shapiro, Michael A; Temkin, Richard J

    2014-01-01

    When using overmoded corrugated waveguide transmission lines for high power applications, it is necessary to control the mode content of the system. Ideally, overmoded corrugated transmission lines operate in the fundamental HE11 mode and provide low losses for long distances. Unwanted higher order modes (HOMs), particularly LP11 and HE12, are often excited in the experimental systems due to practical misalignments in the transmission line system. This paper discusses how the unwanted modes propagate along with the fundamental mode in the transmission line system by formulating an equation that relates the center of power offset and angle of propagation of a beam (for the HE11 and LP11 modes) or the waist size and phase front radius of curvature of a beam (for the HE11 and HE12 modes). By introducing two miter bend correctors into the transmission system-miter bends that have slightly angled or ellipsoidal mirrors-the HOMs can be precisely manipulated in the system. This technique can be used to eliminate small quantities of unwanted modes, thereby creating a nearly pure fundamental mode beam with minimal losses. Examples of these applications are calculated and show the theoretical conversion of up to 10% HOM content into the fundamental HE11 mode with minimal losses.

  13. Analysis of transmission lines loaded with pairs of coupled resonant elements and application to sensors

    Science.gov (United States)

    Naqui, J.; Su, L.; Mata, J.; Martín, F.

    2015-06-01

    This paper is focused on the analysis of transmission lines loaded with pairs of magnetically coupled resonators. We have considered two different structures: (i) a microstrip line loaded with pairs of stepped impedance resonators (SIRs), and (ii) a coplanar waveguide (CPW) transmission line loaded with pairs of split ring resonators (SRRs). In both cases, the line exhibits a single resonance frequency (transmission zero) if the resonators are identical (symmetric structure with regard to the line axis), and this resonance is different to the one of the line loaded with a single resonator due to inter-resonator coupling. If the structures are asymmetric, inter-resonator coupling enhances the distance between the two split resonance frequencies that arise. In spite that the considered lines and loading resonators are very different and are described by different lumped element equivalent circuit models, the phenomenology associated to the effects of coupling is exactly the same, and the resonance frequencies are given by identical expressions. The reported lumped element circuit models of both structures are validated by comparing the circuit simulations with extracted parameters with both electromagnetic simulations and experimental data. These structures can be useful for the implementation of microwave sensors based on symmetry properties.

  14. Robust phase-domain transmission line representation based on time-domain fitting

    Energy Technology Data Exchange (ETDEWEB)

    Nobre, Diana M.; Neves, Washington L.A. [Federal University of Campina Grande (UFCG), Electrical Engineering Department, Av Aprigio Veloso, 882 Campina Grande, PB 58.109-970 (Brazil); Boaventura, Wallace do C. [Federal University of Minas Gerais (UFMG), Electrical Engineering Department, Av Antonio Carlos, 6627 Pampulha, Belo Horizonte, MG 31.270-010 (Brazil)

    2006-05-15

    This work presents a methodology for deriving a phase-domain transmission line representation based on time-domain fitting. A polynomial matrix in the discrete-time domain describes the resulting model. The robustness of the representation, its stability and passivity, is attained by imbedding a set of constraints in the solution of the fitting equations, which are solved using quadratic programming. Results demonstrating from transient simulations the features of the derived representation are presented for the case of an asymmetric, untransposed two-phase transmission line. (author)

  15. Cost benefit analysis of high surge impedance loading (HSIL) HVAC transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Dariani, A.; Kumar, K. [SNC Lavalin Transmission and Distribution, Calgary, AB (Canada)

    2008-07-01

    The amount of power that a given extra high voltage alternating current transmission line can safely carry depends on different thermal and stability/surge impedance loading (SIL) limits. In the case of long lines, the capacity is limited by its SIL level only, which is much below its thermal capacity due to large inductance. Decrease in line inductance and surge impedance increases the SIL and transmission capacity. However, ever increasing demand for electrical energy along with stringent environmental constraints and deregulation of electricity market, have forced the utility companies to consider using compact and high throughput transmission lines in a narrower corridors. Compact transmission lines have lower surge impedance and higher power transfer capability but suffer from higher tower cost, as well as system operational constraints. This paper examined the sensitivity of incremental transmission line cost to the degree of tower compacting and attainable power transfer capability, considering the operational constraints, and other environmental issues such as electromagnetic field effects at the edge of the associated right of way. A set of 31 single and double circuit 500KV tower outlines were considered for analysis. A normalized line surge impedance loading and associated costs were considered for each case. The costs included land easement, foundation, hardware, conductors, engineering and installation. The paper described the methodology for optimizing each configuration based on the functionality, maintainability, capital cost and other parameters for tower selection. It was concluded that the analysis should be extended to include other techniques for increasing power transfer capacity. 5 refs., 1 tab., 4 figs.

  16. Ground-Wave Propagation Effects on Transmission Lines through Error Images

    Directory of Open Access Journals (Sweden)

    Uribe-Campos Felipe Alejandro

    2014-07-01

    Full Text Available Electromagnetic transient calculation of overhead transmission lines is strongly influenced by the natural resistivity of the ground. This varies from 1-10K (Ω·m depending on several media factors and on the physical composition of the ground. The accuracy on the calculation of a system transient response depends in part in the ground return model, which should consider the line geometry, the electrical resistivity and the frequency dependence of the power source. Up to date, there are only a few reports on the specialized literature about analyzing the effects produced by the presence of an imperfectly conducting ground of transmission lines in a transient state. A broad range analysis of three of the most often used ground-return models for calculating electromagnetic transients of overhead transmission lines is performed in this paper. The behavior of modal propagation in ground is analyzed here into effects of first and second order. Finally, a numerical tool based on relative error images is proposed in this paper as an aid for the analyst engineer to estimate the incurred error by using approximate ground-return models when calculating transients of overhead transmission lines.

  17. Reflection and transmission calculations in a multilayer structure with coherent, incoherent, and partially coherent interference, using the transmission line method.

    Science.gov (United States)

    Stathopoulos, N A; Savaidis, S P; Botsialas, A; Ioannidis, Z C; Georgiadou, D G; Vasilopoulou, M; Pagiatakis, G

    2015-02-20

    A generalized transmission line method (TLM) that provides reflection and transmission calculations for a multilayer dielectric structure with coherent, partial coherent, and incoherent layers is presented. The method is deployed on two different application fields. The first application of the method concerns the thickness measurement of the individual layers of an organic light-emitting diode. By using a fitting approach between experimental spectral reflectance measurements and the corresponding TLM calculations, it is shown that the thickness of the films can be estimated. The second application of the TLM concerns the calculation of the external quantum efficiency of an organic photovoltaic with partially coherent rough interfaces between the layers. Numerical results regarding the short circuit photocurrent for different layer thicknesses and rough interfaces are provided and the performance impact of the rough interface is discussed in detail.

  18. New circuit theory of multiconductor transmission lines resulting from a new practice of noise reduction.

    Science.gov (United States)

    Toki, Hiroshi; Sato, Kenji

    2014-01-01

    In modern life, we are surrounded by and filled with electromagnetic noise caused by the dominant use of energy in the form of electricity. This situation is brought about by the fact that the noise is not understood theoretically. A new practice of noise reduction was introduced for the construction of Heavy Ion Medical Accelerator in Chiba (HIMAC). The key concept is a symmetric three-line circuit that arranges power supplies, noise filters and magnets around a third central ground line. A continuous theoretical effort forced us to find a new circuit theory involving a multiconductor transmission-line system starting from Maxwell's equations without any approximation. We discuss the essence of all of these experimental and theoretical developments with the hope to remove unnecessary electromagnetic noise not only from power supplies, but also from all electric devices. The newly derived circuit theory of multiconductor transmission lines is universal, and establishes the validity of the practice of noise reduction.

  19. Optical and electrical enhancement of the propagation time in superconducting transmission lines

    CERN Document Server

    Cho, S H

    2000-01-01

    optical pulse energy and current controlled delays in the propagation time of electrical picosecond pulses in YBa sub 2 Cu sub 3 O sub 7 sub - sub x (YBCO) superconducting transmission lines have been investigated by using picosecond optoelectronic techniques. Electrical pulses, generated using silicon-on-sapphire photoconductive switches driven by a mode-locked Nd:YAG pumped dye laser, are propagated on superconducting transmission lines. The lines are patterned in the geometry of a microstrip and illuminated by the frequency-doubled output of an Nd:YAG laser. The measured propagation time shows a squared dependence on the optical pulse energy. For the applied current dependence, the delay through the line is tuned by 16 psec by varying the bias from zero to 190 mA. The results are in good agreement with the Ginzburg-Landau theory for the case of a uniform current density through a thin film.

  20. Subject Line Preferences and Other Factors Contributing to Coherence and Interaction in Student Discussion Forums

    Science.gov (United States)

    Skogs, Julie

    2013-01-01

    A number of factors may affect student interaction in an asynchronous online discussion forum used in learning. This study deals with student preferences for the subject line of messages and in what ways the choice of subject line contributes to coherence and interaction reflected in the textual and interpersonal functions of the linguistic items…

  1. Controlled closing on shunt reactor compensated transmission lines. Part 2: Application of closing control device for high-speed autoreclosing on BC Hydro 500 kV transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, K.; Hoelzl, C.; Stanek, M. [Univ. of Technology, Vienna (Austria); Carvalho, A.C.; Hofbauer, W.; Hoegg, P.; Avent, B.L.; Peelo, D.F.; Sawada, J.H.

    1997-04-01

    In the past, BC Hydro used circuit breaker closing resistors to limit switching surges on its 500 kV transmission system. This approach was considered undesirable for new transmission lines and an innovative scheme incorporating special transmission line surge arresters and controlled high speed autoreclosing of the circuit breaker was developed. The scheme and its basis as applied on a new 330 km long 500 kV transmission line are described. Actual line switching tests, also described, confirmed the validity of the studies performed and applied design concepts, and the value of the scheme.

  2. Uprating Transmission Lines through the use of an innovative real-time monitoring system

    OpenAIRE

    CLOET, Eric; Lilien, Jean-Louis

    2011-01-01

    This paper describes a brand new method of real-time monitoring of overhead transmission lines. The method makes use of what is called the “Ampacimon” system. The system uses an Ampacimon module, which is a real time monitoring device that deduces the sag by vibration analysis without the need for any line data or environmental data. The Ampacimon system has been proven to be accurate within a sag error margin of ±2%. Peer reviewed

  3. CHARACTERISTICS OF POWER SELF-COMPENSATED TRANSMISSION LINES EXTREMELY COMPACT 330-350 kV

    Directory of Open Access Journals (Sweden)

    Postolaty V.M.

    2013-12-01

    Full Text Available The optimal configuration of phases placement of double circuit compact controlled self-compensated high-voltage power lines (KUSVL with the voltage of 330-500 kV at the condition of achieving of the maximum admissible value of the electric field tension on the surface of split phase at a given design was determined. The parameters of these lines at the extreme values of the angular shift (θ between the circuits’ systems voltages were calculated. It was shown, that the surge impedance of KUSVL without special phase-shifting transformers (e.g. θ = 0˚ is minimal, and is equal (for each phase for the option of 330 kV and wires 3AS-300/39 - 196 ohms, and for voltage of 500 kV and phase conductors 6AS-240/39 –162 ohms. The magnitude of transmission capacity of considered line (for both circuits at rated voltage is maximal and equal to 1118 MW (for 330 kV line and 3080 MW (for 500 kV line. At changing of line to the mode of angle θ = 180˚ (with special phase-shifting transformer surge impedance is maximal and the transmission capacity minimal. Ratio of the maximal value of transmission capacity to the minimal (regulation range reaches values of up to 1.5.

  4. An ME-PC Enhanced HDMR Method for Efficient Statistical Analysis of Multiconductor Transmission Line Networks

    KAUST Repository

    Yucel, Abdulkadir C.

    2015-05-05

    An efficient method for statistically characterizing multiconductor transmission line (MTL) networks subject to a large number of manufacturing uncertainties is presented. The proposed method achieves its efficiency by leveraging a high-dimensional model representation (HDMR) technique that approximates observables (quantities of interest in MTL networks, such as voltages/currents on mission-critical circuits) in terms of iteratively constructed component functions of only the most significant random variables (parameters that characterize the uncertainties in MTL networks, such as conductor locations and widths, and lumped element values). The efficiency of the proposed scheme is further increased using a multielement probabilistic collocation (ME-PC) method to compute the component functions of the HDMR. The ME-PC method makes use of generalized polynomial chaos (gPC) expansions to approximate the component functions, where the expansion coefficients are expressed in terms of integrals of the observable over the random domain. These integrals are numerically evaluated and the observable values at the quadrature/collocation points are computed using a fast deterministic simulator. The proposed method is capable of producing accurate statistical information pertinent to an observable that is rapidly varying across a high-dimensional random domain at a computational cost that is significantly lower than that of gPC or Monte Carlo methods. The applicability, efficiency, and accuracy of the method are demonstrated via statistical characterization of frequency-domain voltages in parallel wire, interconnect, and antenna corporate feed networks.

  5. On-chip sub-terahertz surface plasmon polariton transmission lines in CMOS.

    Science.gov (United States)

    Liang, Yuan; Yu, Hao; Zhang, Hao Chi; Yang, Chang; Cui, Tie Jun

    2015-10-08

    A low-loss and low-crosstalk surface-wave transmission line (T-line) is demonstrated at sub-THz in CMOS. By introducing periodical sub-wavelength structures onto the metal transmission line, surface plasmon polaritons (SPP) are excited and propagate signals via a strongly localized surface wave. Two coupled SPP T-lines and two quasi-TEM T-lines are both fabricated on-chip, each with a separation distance of 2.4 μm using standard 65 nm CMOS technology. Measurement results show that the SPP T-lines achieve wideband reflection coefficient lower than -14 dB and crosstalk ratio better than -24 dB, which is 19 dB lower on average than the traditional T-lines from 220 GHz to 325 GHz. The demonstrated compact and wideband SPP T-lines have shown great potential for future realization of highly dense on-chip sub-THz communications in CMOS.

  6. Canby Area Service Project : Substation and Associated Transmission Line : Environmental Assessment.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp's substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC's Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC's substation can accommodate only about 10 percent of the expected additional electric load. BPA's proposed action is intended to meet SVEC's increasing electric load. BPA proposes to meet SVEC's increasing energy load by tapping into BPA's existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC's Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no environmental impact statement'' is not required.

  7. Canby Area Service Project substation and associated transmission line. Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp`s substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC`s Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC`s substation can accommodate only about 10 percent of the expected additional electric load. BPA`s proposed action is intended to meet SVEC`s increasing electric load. BPA proposes to meet SVEC`s increasing energy load by tapping into BPA`s existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC`s Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no ``environmental impact statement`` is not required.

  8. Analysis and Experimental Evaluation of Power Line Transmission Parameters for Power Line Communication

    Science.gov (United States)

    Mlynek, P.; Misurec, J.; Koutny, M.; Fujdiak, R.; Jedlicka, T.

    2015-04-01

    The article describes a way of evaluating the power line channel frequency response and input impedance by means of the linear time-invariant (LTI) power line generator. Two possible methods are introduced for the calculation of primary parameters: the first method depends on the physical realization and physical dimension of the cable, and the second method is derived from the data provided by typical electrical cable manufacturers. Based on these methods, a comparison of transfer functions was made. This is followed by measurement evaluation and numerical verification on a simple topology

  9. Transmission Line Ampacity Improvements of AltaLink Wind Plant Overhead Tie-Lines Using Weather-Based Dynamic Line Rating

    Energy Technology Data Exchange (ETDEWEB)

    Bhattarai, Bishnu P.; Gentle, Jake P.; Hill, Porter; McJunkin, Tim; Myers, Kurt S.; Abbound, Alex; Renwick, Rodger; Hengst, David

    2017-07-01

    Abstract—Overhead transmission lines (TLs) are conventionally given seasonal ratings based on conservative environmental assumptions. Such an approach often results in underutilization of the line ampacity as the worst conditions prevail only for a short period over a year/season. We presents dynamic line rating (DLR) as an enabling smart grid technology that adaptively computes ratings of TLs based on local weather conditions to utilize additional headroom of existing lines. In particular, general line ampacity state solver utilizes measured weather data for computing the real-time thermal rating of the TLs. The performance of the presented method is demonstrated from a field study of DLR technology implementation on four TL segments at AltaLink, Canada. The performance is evaluated and quantified by comparing the existing static and proposed dynamic line ratings, and the potential benefits of DLR for enhanced transmission assets utilization. For the given line segments, the proposed DLR results in real-time ratings above the seasonal static ratings for most of the time; up to 95.1% of the time, with a mean increase of 72% over static rating.

  10. Simulation study on transient electric shock characteristics of human body under high voltage ac transmission lines

    Science.gov (United States)

    Huang, Tao; Zou, Yanhui; Lv, Jianhong; Yang, Jinchun; Tao, Li; Zhou, Jianfei

    2017-09-01

    Human body under high-voltage AC transmission lines will produce a certain induced voltage due to the electrostatic induction. When the human body contacts with some grounded objects, the charges transfer from the body to the ground and produce contact current which may cause transient electric shock. Using CDEGS and ATP/EMTP, the paper proposes a method for quantitatively calculating the transient electric shock characteristics. It calculates the human body voltage, discharge current and discharge energy under certain 500kV compact-type transmission lines and predicts the corresponding human feelings. The results show that the average root value of discharge current is less than 10mA when the human body is under the 500kV compact-type transmission lines and the human body is overall safe if the transmission lines satisfy the relevant design specifications. It concludes that the electric field strength above the ground should be limited to 4kV/m through the residential area for the purpose of reducing the electromagnetic impact.

  11. Determination of complex permittivity from propagation constant measurement with planar transmission lines

    Science.gov (United States)

    A new two-standard calibration procedure is outlined for determining the complex permittivity of materials from the propagation constant measured with planar transmission lines. Once calibrated, a closed-form expression for the material permittivity is obtained. The effects of radiation and conducto...

  12. Measuring the complex permittivity tensor of uniaxial biological materials with coplanar waveguide transmission line

    Science.gov (United States)

    A simple and accurate technique is described for measuring the uniaxial permittivity tensor of biological materials with a coplanar waveguide transmission-line configuration. Permittivity tensor results are presented for several chicken and beef fresh meat samples at 2.45 GHz....

  13. Exact Solutions for a Local Fractional DDE Associated with a Nonlinear Transmission Line

    Science.gov (United States)

    Aslan, İsmail

    2016-09-01

    Of recent increasing interest in the area of fractional calculus and nonlinear dynamics are fractional differential-difference equations. This study is devoted to a local fractional differential-difference equation which is related to a nonlinear electrical transmission line. Explicit traveling wave solutions (kink/antikink solitons, singular, periodic, rational) are obtained via the discrete tanh method coupled with the fractional complex transform.

  14. The Experimental Verification of Gaussian Beam Coupling for ECH Transmission Line at 400 GHz

    OpenAIRE

    Choe Mun Seok; Sawant Ashwini; Choi EumMi

    2017-01-01

    We design a quasi-optical transmission line system for a 400 GHz gyrotron beam. The 400GHz Gaussian beam is injected to a corrugated waveguide bounced from a quasi-optical mirror. From detailed 2D field patterns of the output beam emitted from the corrugated waveguide, we analyze the mode contents and the source of non-ideal beam expansion

  15. Full Scale Experimental Study on the Air Insulation of 765kV Transmission Lines

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Boo; Shin, Jeong Woon; Cho, Sung Bae; Chang, Sung Chil; Kwak, Joo Shik [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Kim, Ik Soo; Lee, Heyoung Ho; Kang, Young Sik; Lee, Hong Sik; Choi, Beyoung Joo; Kim, Young Bae [Korea Electrotechnology Research Institute, Changwon (Korea, Republic of)

    1997-12-31

    Design and construction of testing yard. Technical specification of impulse voltage generator which was installed in testing yard. Corrosion and statistical analysis of test data. Test object setup and test results of flashover characteristic in various paths. Recommended optimum air clearance of 765kV transmission lines. (author). 163 refs., figs.

  16. A Method For Modeling Discontinuities In A Microwave Coaxial Transmission Line

    Science.gov (United States)

    Otoshi, Tom Y.

    1994-01-01

    A methodology for modeling discountinuities in a coaxial transmission line is presented. The method uses a none-linear least squares fit program to optimize the fit between a theoretical model and experimental data. When the method was applied for modeling discontinuites in a damaged S-band antenna cable, excellent agreement was obtained.

  17. Effect of discontinuities on the group delay of a microwave transmission line

    Science.gov (United States)

    Beatty, R. W.; Otoshi, T. Y.

    1975-01-01

    The problem is considered of the effect of reflections from discontinuities at each end of a transmission line on the group delay at microwave frequencies. Previous work is briefly reviewed and a general analysis is made. Graphical data are presented based upon the formulas developed. Experimental results are given which confirm the theory.

  18. Filter designs based on coupled transmission line model for double split ring resonators

    DEFF Research Database (Denmark)

    Yan, Lei; Tang, Meng; Krozer, Viktor

    2012-01-01

    This work presents a systematic way to design filters based on coupled transmission line model of the microstrip rectangular double split ring resonators (DSRRs). This model allows to estimate all resonance modes of DSRR and extract the quality factors of the structure for filter synthesis purpose...

  19. Evaluation of Transmission Line Model Structures for Silicide-to-Silicon Specific Contact Resistance Extraction

    NARCIS (Netherlands)

    Stavitski, N.; van Dal, Mark J.H.; Lauwers, Anne; Vrancken, Christa; Kovalgin, Alexeij Y.; Wolters, Robertus A.M.

    2008-01-01

    In order to measure silicide-to-silicon specific contact resistance �?c, transmission line model (TLM) structures were proposed as attractive candidates for embedding in CMOS processes. We optimized TLM structures for nickel silicide and platinum silicide and evaluated them for various doping levels

  20. Thermal fluctuations in resonant motion of fluxons on a Josephson transmission line: Theory and experiment

    DEFF Research Database (Denmark)

    Jørgensen, E.; Koshelets, V. P.; Monaco, Roberto

    1982-01-01

    The radiation emission from long and narrow Josephson tunnel junctions dc-current biased on zero-field steps has been ascribed to resonant motion of fluxons on the transmission line. Within this dynamic model a theoretical expression for the radiation linewidth is derived from a full statistical...

  1. Symplectic Hamiltonina formulation of Transmission Line Systems with Boundary Energy Flow

    NARCIS (Netherlands)

    van der Schaft, A.J.; Jeltsema, D

    2007-01-01

    The classical Langrangian and Hamiltonian formulation of an electrical transmission line is reviewed and extended to allow for varying boundary conditions. The method is based on the definition of an infinite-dimensional analogue of the affine Langrangian and Hamiltonian input-output systems

  2. Experimental validation of the stochastic model of a randomly fluctuating transmission-line

    NARCIS (Netherlands)

    Sy, O.O.; Vaessen, J.A.H.M.; Beurden, M.C. van; Michielsen, B.L.; Tijhuis, A.G.; Zwamborn, A.P.M.; Groot, J.S.

    2008-01-01

    A modeling method is proposed to quantify uncertainties affecting electromagnetic interactions. This method considers the uncertainties as random and measures them thanks to probability theory. A practical application is considered through the case of a transmission-line of varying geometry,

  3. Symplectic Hamiltonian Formulation of Transmission Line Systems with Boundary Energy Flow

    NARCIS (Netherlands)

    Jeltsema, Dimitri; Schaft, Arjan van der

    2008-01-01

    The classical Lagrangian and Hamiltonian formulation of an electrical transmission line is reviewed and extended to allow for varying boundary conditions. This extension is based on the definition of an infinite-dimensional analogue of the affine Lagrangian and Hamiltonian input-output systems

  4. Lagrangian and Hamiltonian Formulation of Transmission Line Systems with Boundary Energy Flow

    NARCIS (Netherlands)

    Jeltsema, Dimitri; Schaft, Arjan J. van der

    The classical Lagrangian and Hamiltonian formulation of an electrical transmission line is reviewed and extended to allow for varying boundary conditions, The method is based on the definition of an infinite-dimensional analogue of the affine Lagrangian and Hamiltonian input-output systems

  5. Optical modeling of fiber organic photovoltaic structures using a transmission line method.

    Science.gov (United States)

    Moshonas, N; Stathopoulos, N A; O'Connor, B T; Bedeloglu, A Celik; Savaidis, S P; Vasiliadis, S

    2017-12-01

    An optical model has been developed and evaluated for the calculation of the external quantum efficiency of cylindrical fiber photovoltaic structures. The model is based on the transmission line theory and has been applied on single and bulk heterojunction fiber-photovoltaic cells. Using this model, optimum design characteristics have been proposed for both configurations, and comparison with experimental results has been assessed.

  6. Novel inductive decoupling technique for flexible transceiver arrays of monolithic transmission line resonators.

    Science.gov (United States)

    Kriegl, Roberta; Ginefri, Jean-Christophe; Poirier-Quinot, Marie; Darrasse, Luc; Goluch, Sigrun; Kuehne, Andre; Moser, Ewald; Laistler, Elmar

    2015-04-01

    This article presents a novel inductive decoupling technique for form-fitting coil arrays of monolithic transmission line resonators, which target biomedical applications requiring high signal-to-noise ratio over a large field of view to image anatomical structures varying in size and shape from patient to patient. Individual transmission line resonator elements are mutually decoupled using magnetic flux sharing by overlapping annexes. This decoupling technique was evaluated by electromagnetic simulations and bench measurements for two- and four-element arrays, comparing single- and double-gap transmission line resonator designs, combined either with a basic capacitive matching scheme or inductive pickup loop matching. The best performing array was used in 7T MRI experiments demonstrating its form-fitting ability and parallel imaging potential. The inductively matched double-gap transmission line resonator array provided the best decoupling efficiency in simulations and bench measurements (<-15 dB). The decoupling and parallel imaging performance proved robust against mechanical deformation of the array. The presented decoupling technique combines the robustness of conventional overlap decoupling regarding coil loading and operating frequency with the extended field of view of nonoverlapped coils. While demonstrated on four-element arrays, it can be easily expanded to fabricate readily decoupled form-fitting 2D arrays with an arbitrary number of elements in a single etching process. © 2014 Wiley Periodicals, Inc.

  7. Multiwavelet packet entropy and its application in transmission line fault recognition and classification.

    Science.gov (United States)

    Liu, Zhigang; Han, Zhiwei; Zhang, Yang; Zhang, Qiaoge

    2014-11-01

    Multiwavelets possess better properties than traditional wavelets. Multiwavelet packet transformation has more high-frequency information. Spectral entropy can be applied as an analysis index to the complexity or uncertainty of a signal. This paper tries to define four multiwavelet packet entropies to extract the features of different transmission line faults, and uses a radial basis function (RBF) neural network to recognize and classify 10 fault types of power transmission lines. First, the preprocessing and postprocessing problems of multiwavelets are presented. Shannon entropy and Tsallis entropy are introduced, and their difference is discussed. Second, multiwavelet packet energy entropy, time entropy, Shannon singular entropy, and Tsallis singular entropy are defined as the feature extraction methods of transmission line fault signals. Third, the plan of transmission line fault recognition using multiwavelet packet entropies and an RBF neural network is proposed. Finally, the experimental results show that the plan with the four multiwavelet packet energy entropies defined in this paper achieves better performance in fault recognition. The performance with SA4 (symmetric antisymmetric) multiwavelet packet Tsallis singular entropy is the best among the combinations of different multiwavelet packets and the four multiwavelet packet entropies.

  8. Propagation of nonlinear waves in bi-inductance nonlinear transmission lines

    Science.gov (United States)

    Kengne, Emmanuel; Lakhssassi, Ahmed

    2014-10-01

    We consider a one-dimensional modified complex Ginzburg-Landau equation, which governs the dynamics of matter waves propagating in a discrete bi-inductance nonlinear transmission line containing a finite number of cells. Employing an extended Jacobi elliptic functions expansion method, we present new exact analytical solutions which describe the propagation of periodic and solitary waves in the considered network.

  9. Transmission-Line Super Theory as Antenna Theory for Linear Structures

    Science.gov (United States)

    Rambousky, R.; Nitsch, J.; Tkachenko, S.

    A new generalized transmission-line theory is presented to treat multiconductor as well as antenna systems. Maxwell's equations are cast into the form of classical telegrapher's equations. Two quite different examples are calculated to illustrate the wide use of this theory.

  10. Lightning Protection Performance Assessment of Transmission Line Based on ATP model Automatic Generation

    Directory of Open Access Journals (Sweden)

    Luo Hanwu

    2016-01-01

    Full Text Available This paper presents a novel method to solve the initial lightning breakdown current by combing ATP and MATLAB simulation software effectively, with the aims to evaluate the lightning protection performance of transmission line. Firstly, the executable ATP simulation model is generated automatically according to the required information such as power source parameters, tower parameters, overhead line parameters, grounding resistance and lightning current parameters, etc. through an interface program coded by MATLAB. Then, the data are extracted from the generated LIS files which can be obtained by executing the ATP simulation model, the occurrence of transmission lie breakdown can be determined by the relative data in LIS file. The lightning current amplitude should be reduced when the breakdown occurs, and vice the verse. Thus the initial lightning breakdown current of a transmission line with given parameters can be determined accurately by continuously changing the lightning current amplitude, which is realized by a loop computing algorithm that is coded by MATLAB software. The method proposed in this paper can generate the ATP simulation program automatically, and facilitates the lightning protection performance assessment of transmission line.

  11. Progress on corrugated waveguide components suitable for ITER ECH&CD transmission lines

    Directory of Open Access Journals (Sweden)

    Murphy C.J.

    2012-09-01

    Full Text Available The 2 MW cw requirement for ITER EC transmission lines has led GA to design a number of new and modified components, namely power monitors and polarizers to meet this requirement. In addition, the ITER transmission lines may require sliding joints or bellows to accommodate the thermal expansion of the lines and/or vessel motion. The ex-vessel sections of the EC launchers require double seal waveguides, miter bends and possibly double seal sliding joints to assure tritium retention in this region. GA has developed designs for many of these components and some of them have already been tested at high power at the JAEA RF Test Stand. Thermal analyses of the standard GA power monitor miter bend show that our standard design is suitable for 1 MW cw operation when the H-field is in the plane of the miter bend. For 2 MW cw operation a modified design, which also requires H-plane orientation, has been developed and a prototype has been fabricated and is ready for testing. For long pulse/cw operation, a 2 MW calorimetric miter bend with thermally isolated mirror has been designed and a prototype has been fabricated. Since the mirror is thermally isolated, calorimetry on the mirror cooling water can provide a measure of absorbed power. Such a miter bend, when made in a double seal version, could be useful for monitoring total power at the end of an EC transmission line just before the in-vessel section of an EC launcher. A mode analyzer using an all metal water-cooled beam splitter is being developed for use in measuring in real time the HE11 and higher order mode content or total power in EC transmission lines. Such a high power diagnostic can be very useful in optimizing the alignment of the MOU output into a transmission line and in monitoring the HE11 mode purity at various locations in a transmission line. Prior to making a 63.5 mm 170 GHz version suitable for use on ITER, several prototype 31.75 mm 110 GHz versions have been fabricated and tested at

  12. Controlling the transmission line shape of molecular t-stubs and potential thermoelectric applications

    DEFF Research Database (Denmark)

    Stadler, Robert; Markussen, Troels

    2011-01-01

    Asymmetric line shapes can occur in the transmission function describing electron transport in the vicinity of a minimum caused by quantum interference effects. Such asymmetry can be used to increase the thermoelectric efficiency of molecular junctions. So far, however, asymmetric line shapes have...... been only empirically found for just a few rather complex organic molecules where the origins of the line shapes relation to molecular structure were not resolved. In the present, work we introduce a method to analyze the structure dependence of the asymmetry of interference dips from simple two site...... calculations for a variety of t-stub molecules and also address their suitability for thermoelectric applications....

  13. Miniature Microwave Notch Filters and Comparators Based on Transmission Lines Loaded with Stepped Impedance Resonators (SIRs

    Directory of Open Access Journals (Sweden)

    Lijuan Su

    2015-12-01

    Full Text Available In this paper, different configurations of transmission lines loaded with stepped impedance resonators (SIRs are reviewed. This includes microstrip lines loaded with pairs of SIRs, and coplanar waveguides (CPW loaded with multi-section SIRs. Due to the high electric coupling between the line and the resonant elements, the structures are electrically small, i.e., dimensions are small as compared to the wavelength at the fundamental resonance. The circuit models describing these structures are discussed and validated, and the potential applications as notch filters and comparators are highlighted.

  14. Broadband Impedance Transformer Based on Asymmetric Coupled Transmission Lines in Nonhomogeneous Medium

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Krozer, Viktor; Meincke, Peter

    2007-01-01

    A new broadband quarter-wavelength impedance transformer based on an asymmetric coupled line section is presented. The bandwidth of the coupled line transformer is extended with the help of an interconnecting transmission line. An analytical model for the transformer is developed. The analysis...... of the structure reveals that a fractional bandwidth of more than 100% at –20 dB reflection level can be achieved with such a structure. An experimental transformer circuit has been designed, fabricated and tested. Theoretical and experimental results are fair agreement and confirm the established theory...

  15. Sidney-North Yuma 230-kV Transmission Line Project, Colorado and Nebraska

    Energy Technology Data Exchange (ETDEWEB)

    1991-06-01

    This report describes the need for a 230-kV overhead transmission line to supply power from Sidney, Nebraska to eastern Colorado. The alternative scenario compared to construction of the line is No Action. Rejected alternatives include underground lines and different routing paths, with a possible extension to the Sterling area. Both scenarios are evaluated for environmental effects, cost, and consequences for the eastern Colorado region. The proposed route is determined to be the environmentally preferred choice. 120 refs., 6 figs., 13 tabs. (MHB)

  16. Data-Mining-Based Intelligent Differential Relaying for Transmission Lines Including UPFC and Wind Farms.

    Science.gov (United States)

    Jena, Manas Kumar; Samantaray, Subhransu Ranjan

    2016-01-01

    This paper presents a data-mining-based intelligent differential relaying scheme for transmission lines, including flexible ac transmission system device, such as unified power flow controller (UPFC) and wind farms. Initially, the current and voltage signals are processed through extended Kalman filter phasor measurement unit for phasor estimation, and 21 potential features are computed at both ends of the line. Once the features are extracted at both ends, the corresponding differential features are derived. These differential features are fed to a data-mining model known as decision tree (DT) to provide the final relaying decision. The proposed technique has been extensively tested for single-circuit transmission line, including UPFC and wind farms with in-feed, double-circuit line with UPFC on one line and wind farm as one of the substations with wide variations in operating parameters. The test results obtained from simulation as well as in real-time digital simulator testing indicate that the DT-based intelligent differential relaying scheme is highly reliable and accurate with a response time of 2.25 cycles from the fault inception.

  17. Multivariable time series prediction for the icing process on overhead power transmission line.

    Science.gov (United States)

    Li, Peng; Zhao, Na; Zhou, Donghua; Cao, Min; Li, Jingjie; Shi, Xinling

    2014-01-01

    The design of monitoring and predictive alarm systems is necessary for successful overhead power transmission line icing. Given the characteristics of complexity, nonlinearity, and fitfulness in the line icing process, a model based on a multivariable time series is presented here to predict the icing load of a transmission line. In this model, the time effects of micrometeorology parameters for the icing process have been analyzed. The phase-space reconstruction theory and machine learning method were then applied to establish the prediction model, which fully utilized the history of multivariable time series data in local monitoring systems to represent the mapping relationship between icing load and micrometeorology factors. Relevant to the characteristic of fitfulness in line icing, the simulations were carried out during the same icing process or different process to test the model's prediction precision and robustness. According to the simulation results for the Tao-Luo-Xiong Transmission Line, this model demonstrates a good accuracy of prediction in different process, if the prediction length is less than two hours, and would be helpful for power grid departments when deciding to take action in advance to address potential icing disasters.

  18. Theoretical analysis of the characteristic impedance in metal-insulator-metal plasmonic transmission lines.

    Science.gov (United States)

    Nejati, Hamid; Beirami, Ahmad

    2012-03-15

    We propose a closed form formulation for the impedance of the metal-insulator-metal (MIM) plasmonic transmission lines by solving the Maxwell's equations. We provide approximations for thin and thick insulator layers sandwiched between metallic layers. In the case of very thin dielectric layer, the surface waves on both interfaces are strongly coupled resulting in an almost linear dependence of the impedance of the plasmonic transmission line on the thickness of the insulator layer. On the other hand, for very thick insulator layer, the impedance does not vary with the insulator layer thickness due to the weak-coupling/decoupling of the surface waves on each metal-insulator interface. We demonstrate the effectiveness of our proposed formulation using two test scenarios, namely, almost zero reflection in T-junction and reflection from line discontinuity in the design of Bragg reflectors, where we compare our formulation against previously published results.

  19. Rolled-up transmission line structure for a radiofrequency integrated circuit (RFIC)

    Science.gov (United States)

    Li, Xiuling; Huang, Wen

    2015-04-28

    A rolled-up transmission line structure for a radiofrequency integrated circuit (RFIC) comprises a multilayer sheet in a rolled configuration comprising multiple turns about a longitudinal axis, where the multilayer sheet comprises a conductive pattern layer on a strain-relieved layer. The conductive pattern layer comprises a first conductive film and a second conductive film separated from the first conductive film in a rolling direction. In the rolled configuration, the first conductive film surrounds the longitudinal axis, and the second conductive film surrounds the first conductive film. The first conductive film serves as a signal line and the second conductive film serves as a conductive shield for the rolled-up transmission line structure.

  20. Reduction of radiation loss at small-radius bend using spoof surface plasmon polariton transmission line.

    Science.gov (United States)

    Tang, Wen Xuan; Zhang, Hao Chi; Liu, Jun Feng; Xu, Jie; Cui, Tie Jun

    2017-01-23

    Spoof surface plasmon polariton (SPP) has been realized at low frequencies through corrugated metallic structures. As two-dimensional application, the ultrathin SPP transmission lines (TLs) have been proposed with great potentials for microwave compact circuits due to the strong field confinement and enhancement, as well as controllable dispersive properties. In this paper, we examine the radiation loss at small-radius bend, which may cause severe crosstalk in highly-integrated circuits or systems, for the SPP TLs. We theoretically analyze that the SPP TL has essential merit of low radiation loss, and show better performance of SPP TL than the conventional microstrip line through numerical simulations and experiments. Both simulated and measured results demonstrate that the new type of transmission line can efficiently suppress the radiation loss at small-radius bend, and hence reduce the crosstalk in circuits and systems.

  1. Acoustic transmission line metamaterial with negative/zero/positive refractive index

    Science.gov (United States)

    Bongard, Frédéric; Lissek, Hervé; Mosig, Juan R.

    2010-09-01

    A one-dimensional acoustic negative refractive index metamaterial based on the transmission line approach is presented. This structure implements the dual transmission line concept extensively investigated in microwave engineering. It consists of an acoustic waveguide periodically loaded with membranes realizing the function of series “capacitances” and transversally connected open channels realizing shunt “inductances.” Transmission line based metamaterials can exhibit a negative refractive index without relying on resonance phenomena, which results in a bandwidth of operation much broader than that observed in resonant devices. In the present case, the negative refractive index band extends over almost one octave, from 0.6 to 1 kHz. The developed structure also exhibits a seamless transition between the negative and positive refractive index bands with a zero index at the transition frequency of 1 kHz. At this frequency, the unit cell is only one tenth of the wavelength. Simple acoustic circuit models are introduced, which allow efficient designs both in terms of dispersion and impedance, while accurately describing all the physical phenomena. Using this approach, a good matching at the structure terminations is achieved. Full-wave simulations, made for a 10-cell-long structure, confirm the good performances in terms of dispersion diagram, Bloch impedance, and reflection and transmission coefficients.

  2. A Pilot Directional Protection for HVDC Transmission Line Based on Relative Entropy of Wavelet Energy

    Directory of Open Access Journals (Sweden)

    Sheng Lin

    2015-07-01

    Full Text Available On the basis of analyzing high-voltage direct current (HVDC transmission system and its fault superimposed circuit, the direction of the fault components of the voltage and the current measured at one end of transmission line is certified to be different for internal faults and external faults. As an estimate of the differences between two signals, relative entropy is an effective parameter for recognizing transient signals in HVDC transmission lines. In this paper, the relative entropy of wavelet energy is applied to distinguish internal fault from external fault. For internal faults, the directions of fault components of voltage and current are opposite at the two ends of the transmission line, indicating a huge difference of wavelet energy relative entropy; for external faults, the directions are identical, indicating a small difference. The simulation results based on PSCAD/EMTDC show that the proposed pilot protection system acts accurately for faults under different conditions, and its performance is not affected by fault type, fault location, fault resistance and noise.

  3. B1 field-insensitive transformers for RF-safe transmission lines.

    Science.gov (United States)

    Krafft, Axel; Müller, Sven; Umathum, Reiner; Semmler, Wolfhard; Bock, Michael

    2006-11-01

    Integration of transformers into transmission lines suppresses radiofrequency (RF)-induced heating. New figure-of-eight-shaped transformer coils are compared to conventional loop transformer coils to assess their signal transmission properties and safety profile. The transmission properties of figure-of-eight-shaped transformers were measured and compared to transformers with loop coils. Experiments to quantify the effect of decoupling from the B1 field of the MR system were conducted. Temperature measurements were performed to demonstrate the effective reduction of RF-induced heating. The transformers were investigated during active tracking experiments. Coupling to the B1 field was reduced by 18 dB over conventional loop-shaped transformer coils. MR images showed a significantly reduced artifact for the figure-of-eight- shaped coils generated by local flip-angle amplification. Comparable transmission properties were seen for both transformer types. Temperature measurements showed a maximal temperature increase of 30 K/3.5 K for an unsegmented/segmented cable. With a segmented transmission line a robotic assistance system could be successfully localized using active tracking. The figure-of-eight-shaped transformer design reduces both RF field coupling with the MR system and artifact sizes. Anatomical structure close to the figure-of-eight-shaped transformer may be less obscured as with loop-shaped transformers if these transformers are integrated into e.g. intravascular catheters.

  4. Experimental research on mechanical properties of high voltage transmission lines after the simulated wildfires

    Directory of Open Access Journals (Sweden)

    Wang Tianzheng

    2015-01-01

    Full Text Available In order to determine whether the mechanical performance after the fires of high voltage transmission lines meets the requirements of normal use, this article simulates the wildfire, and does the mechanical performance experiment of high voltage transmission lines(HVT lines after the simulated wildfires. The experiment studied the breaking force and elongation of each layer of 500kv HVT lines after the simulated wildfire. Experimental results show that, after fires, each layer of single aluminum wires of 500kv HVT lines have low breaking force which can be decreased obviously to half of that of new lines. For the steel core, decrease of breaking force is not obvious than aluminum wires, and with the increasing degree of wildfires, it increases gradually to a maximum of 35% of new steel lines’ breaking force. After wildfires, aluminum lines’ resistance ability of deformation decreases significantly, and its plastic deformation increases obviously during uniaxial tension. The steel core has little plastic deformation, and layers of aluminum become fluffy after fires. Therefore, the steel core main bearing load after wildfires.

  5. Cryogenic engineering problems in the development of superconducting power transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Edeskuty, F.J.

    1978-01-01

    The successful operation of the superconducting power transmission line requires the simultaneous development of a cryogenic refrigeration system and cryogenic enclosure in addition to the obvious requirement of a satisfactory cable and its integration into an external power transmission system. The requirements for the cryogenic system originate with the temperature requirements of the cable which are in turn dictated by the superconductor properties. In addition to allowable heat leaks and thermal expansion questions, the cryogenic engineer must also address the problems of electrical and thermal transients, system cooldown, and nonsteady state operation.

  6. Lightning Surge Analysis for 500-kV Transmission Lines using Grounding Model with Dynamic Characteristics

    Science.gov (United States)

    Yasuda, Yoh; Kondo, Shuhei; Hara, Takehisa; Ikeda, Keiichi; Sonoi, Yasuo; Furuoka, Yoshihiro

    It is well known that grounding resistance under huge lightning current injection has current-dependent characteristics, whose mathematical model was already proposed by Liew and Darveniza in 1974. In this paper, where our final goal is reasonable design for lightning protection of 500-kV transmission tower, we adopt the dynamic grounding-resistance model to MODELS-ATP simulation. The effect of the model for the lightning surge analysis on 500-kV transmission line systems is discussed in detail.

  7. Distributed delay-line interferometer based on a Bragg grating in transmission mode

    CERN Document Server

    Preciado, Miguel A; Shu, Xuewen; Sugden, Kate

    2016-01-01

    A novel approach for a delay line interferometer (DLI) based purely on forward Bragg scattering is proposed. We have numerically and experimentally demonstrated that a Bragg grating can deliver the functionality of a DLI in its transmission mode along a single common interfering optical path, instead of the conventional DLI implementation with two interfering optical paths. As a proof of concept, a fiber Bragg grating has been designed and fabricated, showing the desired functionality in the transmission mode of the Bragg grating. The proposed "Bragg-DLI" approach is applicable to any kind of Bragg grating technology, such as volume Bragg gratings, dielectric mirrors, silicon photonics, and other optical waveguide based Bragg structures.

  8. A Novel Transient Fault Current Sensor Based on the PCB Rogowski Coil for Overhead Transmission Lines.

    Science.gov (United States)

    Liu, Yadong; Xie, Xiaolei; Hu, Yue; Qian, Yong; Sheng, Gehao; Jiang, Xiuchen

    2016-05-21

    The accurate detection of high-frequency transient fault currents in overhead transmission lines is the basis of malfunction detection and diagnosis. This paper proposes a novel differential winding printed circuit board (PCB) Rogowski coil for the detection of transient fault currents in overhead transmission lines. The interference mechanism of the sensor surrounding the overhead transmission line is analyzed and the guideline for the interference elimination is obtained, and then a differential winding printed circuit board (PCB) Rogowski coil is proposed, where the branch and return line of the PCB coil were designed to be strictly symmetrical by using a joining structure of two semi-rings and collinear twisted pair differential windings in each semi-ring. A serial test is conducted, including the frequency response, linearity, and anti-interference performance as well as a comparison with commercial sensors. Results show that a PCB Rogowski coil has good linearity and resistance to various external magnetic field interferences, thus enabling it to be widely applied in fault-current-collecting devices.

  9. TRIFL: A design tool for modeling complex magnetically insulated transmission line geometries

    Energy Technology Data Exchange (ETDEWEB)

    Mix, L.P.; Mendel, C.W. Jr.; Seidel, D.B.; Rosenthal, S.E. [Sandia National Labs. Albuquerque, NM (United States)

    1996-12-31

    Vacuum power flow in modern high-power pulsed accelerator transmission lines requires field stresses at the conductors that are so high that negative surfaces become space-charge-limited electron emitters. The performance of these lines can be calculated using two- and three-dimensional, time-dependent, particle-in-cell electromagnetic codes such a TWOQUICK and QUICKSILVER. Extensive design of complex systems using these simulation codes would be extremely expensive and, perhaps, impossible for many of the new pulsed power systems being planned. An analytic model has been developed which predicts the behavior of magnetically insulated transmission lines. The model uses flow impedance parameters with an expanded set of Telegrapher`s equations to calculate radial currents in the transmission lines. This model has been implemented in a code, TRIFL (TRIple-equation-FLow model), on workstations and PC`s and allows one to do detailed designed studies on systems far too complex for similar treatment using a PIC code. TRIFL has been used to design hardware for the PBFA-X accelerator and to analyze PBFA-X data.

  10. Location of Faults in Power Transmission Lines Using the ARIMA Method

    Directory of Open Access Journals (Sweden)

    Danilo Pinto Moreira de Souza

    2017-10-01

    Full Text Available One of the major problems in transmission lines is the occurrence of failures that affect the quality of the electric power supplied, as the exact localization of the fault must be known for correction. In order to streamline the work of maintenance teams and standardize services, this paper proposes a method of locating faults in power transmission lines by analyzing the voltage oscillographic signals extracted at the line monitoring terminals. The developed method relates time series models obtained specifically for each failure pattern. The parameters of the autoregressive integrated moving average (ARIMA model are estimated in order to adjust the voltage curves and calculate the distance from the initial fault localization to the terminals. Simulations of the failures are performed through the ATPDraw ® (5.5 software and the analyses were completed using the RStudio ® (1.0.143 software. The results obtained with respect to the failures, which did not involve earth return, were satisfactory when compared with widely used techniques in the literature, particularly when the fault distance became larger in relation to the beginning of the transmission line.

  11. Long-Haul Dense Space Division Multiplexed Transmission over Low-Crosstalk Heterogeneous 32-Core Transmission Line Using Partial Recirculating Loop System

    DEFF Research Database (Denmark)

    Mizuno, Takayuki; Shibahara, Kohki; Ye, Feihong

    2017-01-01

    In this paper, we present long-haul 32-core dense space division multiplexed (DSDM) unidirectional transmission over a single-mode multicore transmission line. We developed a low-crosstalk heterogeneous 32-core fiber with a square lattice arrangement, and a novel partial recirculating loop system....... The span crosstalk of the 51.4-km 32-core transmission line was less than −34.5 dB. This allowed the transmission of polarization division multiplexed 16 quadrature amplitude modulation (PDM-16QAM) signals through all 32-cores over a long distance exceeding a thousand km. We demonstrate 32-core DSDM 20...... wavelength division multiplexed (WDM) PDM-16QAM transmission over 1644.8 km with a high aggregate spectral efficiency of 201.46 b/s/Hz. Additionally, we examine the effect of crosstalk on the transmission performance of each core, and show that the Q-penalty has strong correlation with inter-core crosstalk....

  12. Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA).

  13. Optimal design of lattice metal constructions of overhead power transmission lines

    Directory of Open Access Journals (Sweden)

    Pustovgar Andrey

    2016-01-01

    Full Text Available The article presents a new concept of design of power lines which allowed us to develop new unified power transmission supports, efficient and reliable ones. For the first time, a method of optimum design of overhead power lines has been developed which considered the power line as a united structural system, the relief, the atmospheric and climatic conditions, the environment pollution, the efficiency requirements, the technological and operational expenditures. The article describes the changes introduced into the requirements for the dimensions and parameters of grid metal works with the minimum mass. The optimum design, the computer-aided assembly process and the use of advanced technologies guarantee the reduction of the construction period and the increase in the maintenance period of power lines.

  14. Comprehensive techniques to determine broadband physically-consistent material characteristics using transmission lines

    Science.gov (United States)

    Zhou, Zhen

    Dispersion, attenuation, and crosstalk are several major challenges that both a high-speed digital and a microwave serial link must overcome to achieve their desirable performance. These phenomena are directly related to the frequency dependency of the dielectric property of the material used in package and interconnect. The dielectric property of a material is commonly measured by its manufacturer in a particular direction at a few discrete frequencies using resonator and waveguide methodology. Since the dielectric property may vary during manufacturing processing, the measurements taken by the manufacturer might be not adequate. Moreover, the dielectric property of a material in a bandwidth that covers at least the second harmonics of the fundamental operational frequency is required to accurately predict the link performance. One of the efforts in this research is to investigate the methodology of realizing broadband characteristics of the dielectric property of a material in its "as packaged" configuration using various transmission line topologies, such as microstrip line and Co-Planar Waveguide (CPW). Transitions from CPW to other transmission line topologies are mandatory if CPW probes are used to achieve broadband and repeatable measurements. Since microstrip line is one of the transmission line topologies involved in this research, a research effort is dedicated to develop a broadband CPW-to-microstrip line transition. An effort is also expended to creating casual material models that can be used in electromagnetic simulators to appropriately model the link based on the polarization mechanism of the materials. In addition to focusing on the measurement method in frequency domain, Short Pulse Propagation (SPP), a time domain method, is investigated as well. A virtual test bench is created to investigate the correlation between impedance variations in stripline structures due to fabricated tolerance and the attenuation predicted by SPP.

  15. [Practical aspects of taking measurements of electromagnetic fields in the surrounding of overhead transmission lines].

    Science.gov (United States)

    Szuba, Marek

    2009-01-01

    Identification of electromagnetic fields in the vicinity of high voltage overhead transmission lines requires taking measurements and determining, on their basis, the maximum values of electric (Emax) and magnetic (Hmax) field strength, as well as the width of the area with electric field strength exceeding 1 kV/m. Measurements should be carried out in the places, where the distance between phase wires and the ground is smallest, and their results converted to conditions expected at the most disadvantageous parameters of the work of line in terms of their effect on the environment. This requires taking into consideration the maximum voltage of the transmission line, as well as the highest acceptable temperature of wires. In a single-circuit line, convertion of the measured values to expected maximum values of Emax and Hmax is not difficult, although it requires knowledge of cross-profiles in spans, in which measurements were taken. However, recounting the values of magnetic field strength produced by two-circuit lines creates a serious problem. Since in the majority of cases, the measurements in the surrounding of two-circuit lines are carried out at asymmetrical currents in both circuits, converting their results to symmetrical currents of the lines is practically impossible. Therefore, the results of the measurements of magnetic field strength carried out at the asymmetrical current of a two-circuit line cannot provide the basis for assessing the possibility of exceeding the allowable value of magnetic field intensity determined in the binding regulations. Such an assessment can only be done on the basis of the results of relevant calculations.

  16. Transmission competency of single-female Xiphinema index lines for Grapevine fanleaf virus.

    Science.gov (United States)

    Demangeat, Gérard; Komar, Véronique; Van-Ghelder, Cyril; Voisin, Roger; Lemaire, Olivier; Esmenjaud, Daniel; Fuchs, Marc

    2010-04-01

    Grapevine fanleaf virus (GFLV) is vectored specifically from grapevine to grapevine by the ectoparasitic nematode Xiphinema index. Limited information is available on the vector competency of X. index populations from diverse geographical origins. We determined the transmissibility of two GFLV strains showing 4.6% amino acid divergence within their coat protein (e.g., strains F13 and GHu) by seven clonal lines of X. index developed from seven distinct populations from the Mediterranean basin (Cyprus, southern France, Israel, Italy, and Spain), northern France, and California. X. index lines derived from single adult females were produced on fig (Ficus carica) plants to obtain genetically homogenous aviruliferous clones. A comparative reproductive rate analysis on Vitis rupestris du Lot and V. vinifera cv. Cabernet Sauvignon showed significant differences among clones, with the single-female Cyprus line showing the highest rate (30-fold the initial population) and the Spain and California lines showing the lowest rate (10-fold increase), regardless of the grapevine genotype. However, there was no differential vector competency among the seven X. index lines for GFLV strains F13 and GHu. The implications of our findings for the dynamic of GFLV transmission in vineyards and screening of Vitis spp. for resistance to GFLV are discussed.

  17. High power testing of water-cooled waveguide for ITER-like ECH transmission lines

    Science.gov (United States)

    Anderson, J. P.; Doane, J. L.; Grunloh, H. J.; O'Neill, R. C.; Ikeda, R.; Oda, Y.; Takahashi, K.; Sakamoto, K.

    2017-05-01

    The results of high power testing of new water-cooled ECH waveguide components for ITER are presented. The components are a precision-coupled 4.2 m waveguide assembly, a short expansion joint, and water-cooled waveguide for gyrotron commissioning. The testing was conducted at the QST Naka Fusion Institute using gyrotron pulses of 450 kW at 170 GHz for 300 s. Analysis shows that the power absorbed per unit length for the various waveguide components are dependent on location in the transmission line with respect to high order mode generators, such as miter bends. Additionally, larger-than-expected reflections from the load led to high absorption levels in the transmission line.

  18. Rényi entropies of electrical transmission lines with Fibonacci distribution of inductances

    Energy Technology Data Exchange (ETDEWEB)

    Lazo, E., E-mail: elazo@uta.cl [Departamento de Física, Facultad de Ciencias, Universidad de Tarapacá, Arica (Chile); Mellado, F. [Departamento de Física, Facultad de Ciencias, Universidad de Tarapacá, Arica (Chile); Escuela Universitaria de Ingeniería Eléctrica-Electrónica, Universidad de Tarapacá, Arica (Chile); Saavedra, E. [Departamento de Física, Facultad de Ciencias, Universidad de Tarapacá, Arica (Chile)

    2012-10-01

    We study classical dual transmission lines with constant capacitances C{sub j}=C{sub 0}, ∀j, when we distribute two inductance values L{sub A} and L{sub B} according to the Fibonacci sequence. Using the electric current function I{sub j}(ω), we study the normalized localization length Λ(ω), the Rényi entropies R{sub m}(ω) and the normalized information length β(ω). We found three kinds of behavior of the I{sub j}(ω) function: localized, extended and intermediate. In addition, it is found that the transmission line with Fibonacci distribution of inductances shows a behavior characteristic of quasi-periodic systems, namely, a self-similar frequency spectrum, where each subband is divided into three subbands, but the number of global subbands is greater than four.

  19. Large field-of-view transmission line resonator for high field MRI

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Johannesson, Kristjan Sundgaard; Boer, Vincent

    2016-01-01

    Transmission line resonators is often a preferable choice for coils in high field magnetic resonance imaging (MRI), because they provide a number of advantages over traditional loop coils. The size of such resonators, however, is limited to shorter than half a wavelength due to high standing wave...... ratio, which leads to inhomogeneous field distribution along the resonator. In this work, it is demonstrated that the resonator length can be extended to over half a wavelength with the help of series capacitors. The approach allows for reduced standing wave ratio and improved field homogeneity....... Achieved magnetic field distribution is compared to the conventional transmission line resonator. Imaging experiments are performed using 7 Tesla MRI system. The developed resonator is useful for building coils with large field-of-view....

  20. Stress Analysis of Boom of Special Mobile Crane for Plain Region in Transmission Line

    Science.gov (United States)

    Qin, Jian; Shao, Tao; Chen, Jun; Wan, Jiancheng; Li, Zhonghuan; Jiang, Ming

    2017-10-01

    Basis of the boom force analysis of special mobile crane for plain region in transmission line, the load type of boom design is confirmed. According to the different combinations of boom sections, the composite pattern of the different boom length is obtained to suit the actual conditions of boom overlapping. The large deformation model is employed with FEM to simulate the stress distribution of boom, and the calculation results are checked. The performance curves of rated load with different arm length and different working range are obtained, which ensures the lifting capacity of special mobile crane meeting the requirement of tower erection of transmission line. The proposed FEM of boom of mobile crane would provide certain guiding and reference to the boom design.

  1. Performance Analysis of the ITER Plasma Position Reflectometry (PPR) Ex-vessel Transmission Lines

    Science.gov (United States)

    Martínez-Fernández, J.; Simonetto, A.; Cappa, Á.; Rincón, M. E.; Cabrera, S.; Ramos, F. J.

    2017-11-01

    As the design of the ITER Plasma Position Reflectometry (PPR) diagnostic progresses, some segments of the transmission line have become fully specified and estimations of their performance can already be obtained. This work presents the calculations carried out for the longest section of the PPR, which is in final state of design and will be the main contributor to the total system performance. Considering the 88.9 mm circular corrugated waveguide (CCWG) that was previously chosen, signal degradation calculations have been performed. Different degradation sources have been studied: ohmic attenuation losses for CCWG; mode conversion losses for gaps, mitre bends, waveguide sag and different types of misalignments; reflection and absorption losses due to microwave windows and coupling losses to free space Gaussian beam. Contributions from all these sources have been integrated to give a global estimation of performance in the transmission lines segments under study.

  2. Differential surface plasmon polaritons transmission line with controllable common mode rejection.

    Science.gov (United States)

    Zhang, Xue-Feng; Chen, Jian-Xin; Gao, Rui-Feng; Xu, Chen; Bao, Zhi-Hua

    2017-06-07

    In this paper, a spoof surface plasmon polarions (SPPs) transmission line is designed by patterning thin metal film in open-cross shape arranged in array. Numerical simulations show the proposed open-cross array can support spoof SPPs with enlarged propagation constant and hence enhanced confinement at metal/dielectric interface as compared to the reported ultra-thin plasmonic waveguide with the rectangular groove or solid-cross. Furthermore, a differential transmission line pair is built with such two close plasmonic arrays. A narrow metal strip locates at the symmetrical plane of the two SPPs waveguides and acts as a resonator to realize common-mode rejection at specific frequency. The notch frequency for common mode can be adjusted by tuning the metal strip length of the resonator while differential mode propagation remains unaffected. Both simulated and experimental results with good agreement are given to verify the proposed idea.

  3. Transmission line inversion and synthesis from the point of view of transient response

    Science.gov (United States)

    Sondhi, M. M.

    1972-01-01

    The transmission line inversion problem is applied to the speech communication process. The problem involves acquiring information necessary for synthesis of speech and for making models of the speech production mechanism. Formulation for the problem is derived from an analysis of the human vocal tract functions. It is known that speech sounds are produced by acoustic excitation of the tract by means of quasi-periodic pulses from the vocal cords during vowel sounds and turbulent air flow at various points along the tract during fricative sounds. By assuming plane wave propagation, differential equations are obtained relating the cross sectional area of the tract, the pressure, and the volume velocity. By replacing the pressure factor with a voltage factor and the volume velocity by current, the problem becomes a transmission line problem.

  4. Minimal inductance for axisymmetric transmission lines with radially dependent anode-cathode gap

    Directory of Open Access Journals (Sweden)

    Eduardo M. Waisman

    2009-09-01

    Full Text Available We extend the variational calculus technique for inductance minimization of constant gap axisymmetric transmission lines (TL, introduced by Hurricane [J. Appl. Phys. 95, 4503 (2004JAPIAU0021-897910.1063/1.1687986], to the case in which the anode-cathode gap is a linear function of the midgap radius. The full analytic optimal midgap solution curve z(r yielding minimum inductance is obtained in terms of a single parameter ρ_{0}, determined numerically by imposing that z(r goes through prescribed end points. The radius of curvature ρ(r of the optimal curve is obtained everywhere the function is defined, even outside of the end point range, and it is shown that a convenient choice is ρ_{0}=ρ(0. The value of the transmission line inductance is calculated by 1D numerical quadrature. A simple numerical technique is introduced for TL with nonlinear radial gap dependence.

  5. Monitoring of Overhead Transmission Lines: A Review from the Perspective of Contactless Technologies

    Science.gov (United States)

    Khawaja, Arsalan Habib; Huang, Qi; Khan, Zeashan Hameed

    2017-12-01

    This paper describes a comprehensive review of non-contact technologies for overhead power transmission lines. Due to ever increasing emphasis on reducing accidents and speeding up diagnosis for automatically controlled grids, real time remote sensing and actuation is the new horizon for smart grid implementation. The technology overview with emphasis on the practical implementation of advanced non-contact technologies is discussed in this paper while considering optimization of the high voltage transmission lines parameters. In case of fault, the voltage and the current exceed limits of operation and hence real time reporting for control and diagnosis is a critical requirement. This paper aims to form a strong foundation for control and diagnosis of future power distribution systems so that a practitioner or researcher can make choices for a workable solution in smart grid implementation based on non-contact sensing.

  6. Calculation method of multi-span tension stringing in transmission line

    Science.gov (United States)

    Qin, Jian; Wan, Jiancheng; Feng, Liang; Peng, Fei; Qiao, Liang

    2017-10-01

    The process of multi-span tension stringing in transmission line is analysed based on elastic catenary equation. From the tower condition of transmission line, the conservation equations of span spacing and elevation difference are built for conductor, and the tension balance equations of conductor between different spans are got considering the rolling friction of the pulley. Added the external tension condition, the overall nonlinear equations of multi-span tension stringing are set up which can be solved by Newton iteration method. The iterative process is listed for the calculation of the conductor tension and sags in engineering problems. Compared the results with the numerical example, this method are proved the reliability. The calculation amount, efficiency and accuracy of this method can meet the needs of the practical engineering.

  7. Coupling mid-infrared light from a photonic crystal waveguide to metallic transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Blanco-Redondo, Andrea, E-mail: andrea.blanco@tecnalia.com, E-mail: r.hillenbrand@nanogune.eu [ICT-European Software Institute Division, Tecnalia, Ibaizabal Bidea, Ed. 202, 48170 Zamudio, Bizkaia (Spain); Dpto. Electronica y Telecom., E.T.S. Ingeniería Bilbao, UPV/EHU, Alda. Urquijo, 48103 Bilbao, Bizkaia (Spain); Sarriugarte, Paulo [Nanooptics Group, CIC nanoGUNE Consolider, 20018 Donostia–San Sebastian, Gipuzkoa (Spain); Garcia-Adeva, Angel [Dpto. Fisica Aplicada I, E.T.S. Ingeniería de Bilbao, UPV-EHU, Alda. Urquijo, 48103 Bilbao, Bizkaia (Spain); Zubia, Joseba [Dpto. Electronica y Telecom., E.T.S. Ingeniería Bilbao, UPV/EHU, Alda. Urquijo, 48103 Bilbao, Bizkaia (Spain); Hillenbrand, Rainer, E-mail: andrea.blanco@tecnalia.com, E-mail: r.hillenbrand@nanogune.eu [Nanooptics Group, CIC nanoGUNE Consolider, 20018 Donostia–San Sebastian, Gipuzkoa (Spain); IKERBASQUE, Basque Foundation for Science, 48011 Bilbao, Bizkaia (Spain)

    2014-01-06

    We propose and theoretically study a hybrid structure consisting of a photonic crystal waveguide (PhC-wg) and a two-wire metallic transmission line (TL), engineered for efficient transfer of mid-infrared (mid-IR) light between them. An efficiency of 32% is obtained for the coupling from the transverse magnetic (TM) photonic mode to the symmetric mode of the TL, with a predicted intensity enhancement factor of 53 at the transmission line surface. The strong coupling is explained by the small phase velocity mismatch and sufficient spatial overlapping between the modes. This hybrid structure could find applications in highly integrated mid-IR photonic-plasmonic devices for biological and gas sensing, among others.

  8. Insulator and Clerance Requirements in Overhead Line Transmission Systems without Shield Wires

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    This paper theoretically examines the required insulation lengths and clearances in 400 kV overhead line systems when not making use of ground wires as lightning protection. The influence of lightning strikes to the system is investigated based on dynamic transmission line simulations of a 400 k......V section in PSCAD/EMTDC. The performance of the system without shield wires is considerably deteriorated if no steps are taken to increase the insulation level of the system. However by increasing the insulator lengths and clearances in the system greatly the performance can be improved....

  9. TWO APPROACHES TO CALCULATION OF SPLIT PHASE DANCING OF OVERHEAD ELECTRICAL TRANSMISSION LINE

    Directory of Open Access Journals (Sweden)

    I. I. Sergey

    2005-01-01

    Full Text Available The paper shows two approaches to mathematical modeling of split phase dancing of overhead electrical transmission line. The first approach is based on calculative method when a phase is in the shape of flexible elastic thread connected with rigid rods. The phase is represented with equivalent wire in the second approach. Principle of mechanics relations has been used to set combined boundary problem of split phase dynamics. Two packets of computer programs for calculation of split phase dancing of overhead (electric power line have been set up and tested.

  10. Transmission line model for coupled rectangular double split‐ring resonators

    DEFF Research Database (Denmark)

    Yan, Lei; Tang, Meng; Krozer, Viktor

    2011-01-01

    In this work, a model based on a coupled transmission line formulation is developed for microstrip rectangular double split‐ring resonators (DSRRs). This model allows using the physical dimensions of the DSRRs as an input avoiding commonly used extraction of equivalent parameters. The model...... DSRRs, which allows for an accurate modeling of densely packed multiresonator structures. The model is verified by comparison with measured DSRRs‐loaded microstrip line performance. The developed model can be effectively used to save computation resources associated with full wave electromagnetic...

  11. A long analog transmission line for the VELO read-out

    CERN Document Server

    Frei, R

    2001-01-01

    The radiation level in the LHCb cavern strongly suggests to place the L1 Electronics behind the concrete wall to avoid Single Event Upset (SEU) in FPGA. For the VELO this implies the necessity for ~60 m long transmission lines from the VELO vacuum vessel to the L1 electronics. This note reports a feasibility study for such a long connection using twisted pair cables.

  12. Ignition of a Thermonuclear Detonation Wave in the Focus of Two Magnetically Insulated Transmission Lines

    Science.gov (United States)

    Winterberg, F.

    2003-04-01

    For the ignition of a thermonuclear detonation wave assisted by a strong magnetic field, it is proposed to use two concentrically nested magnetically insulated transmission lines, the inner one transmitting a high- voltage lower-current-, and the outer one a high-current lower-voltage- electromagnetic pulse drawn from two Marx generators. The concept has the potential of large thermonuclear gains with an input energy conceivably as small as 105 J.

  13. An Operator-Difference Method for Telegraph Equations Arising in Transmission Lines

    Directory of Open Access Journals (Sweden)

    Mehmet Emir Koksal

    2011-01-01

    stable. Stability estimates for the solution of the difference scheme are presented. Various numerical examples are tested for showing the usefulness of the difference scheme. Numerical solutions of the examples are provided using modified unconditionally absolutely stable second-order operator-difference scheme. Finally, the obtained results are discussed by comparing with other existing numerical solutions. The modified difference scheme is applied to analyze a real engineering problem related with a lossy power transmission line.

  14. Particle trap with dielectric barrier for use in gas insulated transmission lines

    Science.gov (United States)

    Dale, S.J.

    1982-06-15

    A gas-insulated transmission line includes an outer sheath, an inner conductor within the outer sheath, insulating supports supporting the inner conductor within the outer sheath, and an insulating gas electrically insulating the inner conductor from the outer sheath. An apertured particle trapping electrode is disposed within the outer sheath, and the electrode has a pair of dielectric members secured at each longitudinal end thereof, with the dielectric members extending outwardly from the apertured electrode. 7 figs.

  15. Multiresolution Time-Domain Analysis of Multiconductor Transmission Lines Terminated in Linear Loads

    OpenAIRE

    Zongliang Tong; Lei Sun; Ying Li; Luis Diaz Angulo; Salvador Gonzalez Garcia; Jianshu Luo

    2017-01-01

    This paper derives a multiresolution time-domain (MRTD) scheme for the multiconductor transmission line (MTL) equations based on Daubechies’ scaling functions. The terminations are characterized by a state-variable formulation which allows a general description of the termination networks. For the linear load terminations, a method incorporating the terminal constraints is proposed to work out the scheme at and close to the terminations. The MRTD scheme is implemented with different basis fun...

  16. Left Hand Mode Transmission Line Characteristics Made by F-SIR Structure on PCB

    Science.gov (United States)

    Yanagisawa, Ryosuke; Kayano, Yoshiki; Inoue, Hiroshi

    Basic left hand mode transmission line (LH mode TL) characteristics made on PCB is an important future issue for the application of the EMC field. In this paper, possibility of a LH mode TL characteristic made by a folded-stepped impedance resonator (F-SIR) type is investigated experimentally and numerically. The experimental and calculated from FEM and equivalent circuit results indicate that some backward propagation characteristic and negative group delay can be established by F-SIR structure.

  17. Composite Grounding Application of Transmission Line Tower with Flexible Graphite Grounding Material

    Science.gov (United States)

    Liu, Hongtao; Zhang, Lei; Xiong, Jia; Cui, Zhenxing; Yang, Qi

    2017-07-01

    To solve the metal corrosion problem of transmission line tower grounding grid, a composite grounding material technique based on flexible graphite grounding is proposed. Using CDEGS software, the power frequency grounding resistances with different soils layers and different ground network size of tower are simulated. The researches show that layered soil resistance can be reduced by laying vertical grounding body and uniform soil can reduce ground resistance by increasing grounding network size.

  18. Critical parameters affecting the design of high frequency transmission lines in standard CMOS technology

    KAUST Repository

    Al Attar, Talal

    2017-05-13

    Different structures of transmission lines were designed and fabricated in standard CMOS technology to estimate some critical parameters including the RMS value of the surface roughness and the loss tangent. The input impedances for frequencies up to 50 GHz were modeled and compared with measurements. The results demonstrated a strong correlation between the used model with the proposed coefficients and the measured results, attesting the robustness of the model and the reliability of the incorporated coefficients values.

  19. Efficient design of multituned transmission line NMR probes: the electrical engineering approach.

    Science.gov (United States)

    Frydel, J A; Krzystyniak, M; Pienkowski, D; Pietrzak, M; de Sousa Amadeu, N; Ratajczyk, T; Idzik, K; Gutmann, T; Tietze, D; Voigt, S; Fenn, A; Limbach, H H; Buntkowsky, G

    2011-01-01

    Transmission line-based multi-channel solid state NMR probes have many advantages regarding the cost of construction, number of RF-channels, and achievable RF-power levels. Nevertheless, these probes are only rarely employed in solid state-NMR-labs, mainly owing to the difficult experimental determination of the necessary RF-parameters. Here, the efficient design of multi-channel solid state MAS-NMR probes employing transmission line theory and modern techniques of electrical engineering is presented. As technical realization a five-channel ((1)H, (31)P, (13)C, (2)H and (15)N) probe for operation at 7 Tesla is described. This very cost efficient design goal is a multi port single coil transmission line probe based on the design developed by Schaefer and McKay. The electrical performance of the probe is determined by measuring of Scattering matrix parameters (S-parameters) in particular input/output ports. These parameters are compared to the calculated parameters of the design employing the S-matrix formalism. It is shown that the S-matrix formalism provides an excellent tool for examination of transmission line probes and thus the tool for a rational design of these probes. On the other hand, the resulting design provides excellent electrical performance. From a point of view of Nuclear Magnetic Resonance (NMR), calibration spectra of particular ports (channels) are of great importance. The estimation of the π/2 pulses length for all five NMR channels is presented. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. System for Relay Protection Command Transmission by High-Voltage Lines

    Directory of Open Access Journals (Sweden)

    D. A. Yenkov

    2009-01-01

    Full Text Available Development of a system for relay protection command transmission by high-voltage lines is shown in the paper. The paper describes an architecture of the system, main principles of its operation, engineering aspects of the development that is accomplishment of technical requirements, solution of trades-off. Justification of the selected design and an algorithm of the reliable detection of relay protection signals are given in the paper.

  1. Adaptive Neurofuzzy Inference System-Based Pollution Severity Prediction of Polymeric Insulators in Power Transmission Lines

    OpenAIRE

    Muniraj, C.; Chandrasekar, S.

    2011-01-01

    This paper presents the prediction of pollution severity of the polymeric insulators used in power transmission lines using adaptive neurofuzzy inference system (ANFIS) model. In this work, laboratory-based pollution performance tests were carried out on 11 kV silicone rubber polymeric insulator under AC voltage at different pollution levels with sodium chloride as a contaminant. Leakage current was measured during the laboratory tests. Time domain and frequency domain characteristics of leak...

  2. Short-Circuit Calculations for a Transmission Line in the Algerian Power Network Compensated by Thyristor Controlled Voltage Regulator

    Directory of Open Access Journals (Sweden)

    ZELLAGUI Mohamed

    2014-10-01

    Full Text Available In this paper, the impact of using the Thyristor Controlled Voltage Regulator (TCVR on short-circuit calculations is studied for a high voltage transmission line in case of a phase to earth fault in the presence of a fault resistance (RF. A 400 kV single transmission line, in the Algerian power network, is used for this study where the line is compensated by TCVR FACTS device to control the voltage and active power of the line. The impact of the fault resistance is studied to reflect its effect on short-circuit calculations including symmetrical current components, transmission line currents, voltage symmetrical components, and transmission line voltages, without and with TCVR. The obtained simulation results match the presented theoretical analysis.

  3. Fiber Bragg Grating sensor for fault detection in radial and network transmission lines.

    Science.gov (United States)

    Moghadas, Amin A; Shadaram, Mehdi

    2010-01-01

    In this paper, a fiber optic based sensor capable of fault detection in both radial and network overhead transmission power line systems is investigated. Bragg wavelength shift is used to measure the fault current and detect fault in power systems. Magnetic fields generated by currents in the overhead transmission lines cause a strain in magnetostrictive material which is then detected by Fiber Bragg Grating (FBG). The Fiber Bragg interrogator senses the reflected FBG signals, and the Bragg wavelength shift is calculated and the signals are processed. A broadband light source in the control room scans the shift in the reflected signal. Any surge in the magnetic field relates to an increased fault current at a certain location. Also, fault location can be precisely defined with an artificial neural network (ANN) algorithm. This algorithm can be easily coordinated with other protective devices. It is shown that the faults in the overhead transmission line cause a detectable wavelength shift on the reflected signal of FBG and can be used to detect and classify different kind of faults. The proposed method has been extensively tested by simulation and results confirm that the proposed scheme is able to detect different kinds of fault in both radial and network system.

  4. Bias-field controlled phasing and power combination of gyromagnetic nonlinear transmission lines.

    Science.gov (United States)

    Reale, D V; Bragg, J-W B; Gonsalves, N R; Johnson, J M; Neuber, A A; Dickens, J C; Mankowski, J J

    2014-05-01

    Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance.

  5. Application Research on Drag Reduced Conductors for Electric Power Transmission Lines in Strong Wind Areas

    Directory of Open Access Journals (Sweden)

    Li Dong Qing

    2016-01-01

    Full Text Available The breeze vibration duration of conductors is long, the vibration amplitude is strong and the frequency range is wide for electric power transmission lines in strong wind areas, which seriously affects the safe and stable operation of transmission lines. There are two design schemes of conductors which can achieve the purpose of reducing wind-induced disaster. One is enhancing the structural strength of conductors to withstand wind load, but the investment is enormous and the effect is limited. The other is developing drag reduced conductors to reduce wind load by changing conductor structure. This paper started from application feasibility analysis of drag reduced conductors and designed four drag reduced conductors by structure optimization of the conventional aluminium conductor steel reinforced JL/G1A-630/45-45/7, denoted as DFY630/45(45°-R3.5, DFY630/45(60°-R3.5, DFY630/45(45°–R3.2 and DFY630/45(60°-R3.2, respectively. The wind tunnel test was performed and the wind resistance coefficients in unit length of five conductors were compared. Result showed that the wind resistance coefficients in unit length of four drag reduced conductors were obviously lower than that of the conventional conductor. By controlling the manufacturing process, popularization and application of drag reduced conductors for transmission lines in strong wind areas can be realized.

  6. Modeling particle emission and power flow in pulsed-power driven, nonuniform transmission lines

    Directory of Open Access Journals (Sweden)

    Nichelle Bruner

    2008-04-01

    Full Text Available Pulsed-power driven x-ray radiographic systems are being developed to operate at higher power in an effort to increase source brightness and penetration power. Essential to the design of these systems is a thorough understanding of electron power flow in the transmission line that couples the pulsed-power driver to the load. In this paper, analytic theory and fully relativistic particle-in-cell simulations are used to model power flow in several experimental transmission-line geometries fielded on Sandia National Laboratories’ upgraded Radiographic Integrated Test Stand [IEEE Trans. Plasma Sci. 28, 1653 (2000ITPSBD0093-381310.1109/27.901250]. Good agreement with measured electrical currents is demonstrated on a shot-by-shot basis for simulations which include detailed models accounting for space-charge-limited electron emission, surface heating, and stimulated particle emission. Resonant cavity modes related to the transmission-line impedance transitions are also shown to be excited by electron power flow. These modes can drive oscillations in the output power of the system, degrading radiographic resolution.

  7. Backpropagation Neural Network Modeling for Fault Location in Transmission Line 150 kV

    Directory of Open Access Journals (Sweden)

    Azriyenni Narwan

    2014-03-01

    Full Text Available In this topic research was provided about the backpropagation neural network to detect fault location in transmission line 150 kV between substation to substation. The distance relay is one of the good protective device and safety devices that often used on transmission line 150 kV. The disturbances in power system are used distance relay protection equipment in the transmission line. However, it needs more increasing large load and network systems are increasing complex. The protection system use the digital control, in order to avoid the error calculation of the distance relay impedance settings and spent time will be more efficient. Then backpropagation neural network is a computational model that uses the training process that can be used to solve the problem of work limitations of distance protection relays. The backpropagation neural network does not have limitations cause of the impedance range setting. If the output gives the wrong result, so the correct of the weights can be minimized and also the response of galat, the backpropagation neural network is expected to be closer to the correct value. In the end, backpropagation neural network modeling is expected to detect the fault location and identify operational output current circuit breaker was tripped it. The tests are performance with interconnected system 150 kV of Riau Region.

  8. Alleviation SSR and Low Frequency Power Oscillations in Series Compensated Transmission Line using SVC Supplementary Controllers

    Science.gov (United States)

    Kumar, Sanjiv; Kumar, Narendra

    2017-06-01

    In this work, supplementary sub-synchronous damping controllers (SSDC) are proposed for damping sub-synchronous oscillations in power systems with series compensated transmission lines. Series compensation have extensively been used as effective means of increasing the power transfer capability of a transmission lines and improving transient stability limits of power systems. Series compensation with transmission lines may cause sub-synchronous resonance (SSR). The eigenvalue investigation tool is used to ascertain the existence of SSR. It is shown that the addition of supplementary controller is able to stabilize all unstable modes for T-network model. Eigenvalue investigation and time domain transient simulation of detailed nonlinear system are considered to investigate the performance of the controllers. The efficacies of the suggested supplementary controllers are compared on the IEEE first benchmark model for computer simulations of SSR by means of time domain simulation in Matlab/Simulink environment. Supplementary SSDC are considered in order to compare effectiveness of SSDC during higher loading in alleviating the small signal stability problem.

  9. Propagation and localization of quantum dot emission along a gap-plasmonic transmission line.

    Science.gov (United States)

    Castro-Lopez, M; Manjavacas, A; García de Abajo, J; van Hulst, N F

    2015-11-16

    Plasmonic transmission lines have great potential to serve as direct interconnects between nanoscale light spots. The guiding of gap plasmons in the slot between adjacent nanowire pairs provides improved propagation of surface plasmon polaritons while keeping strong light confinement. Yet propagation is fundamentally limited by losses in the metal. Here we show a workaround operation of the gap-plasmon transmission line, exploiting both gap and external modes present in the structure. Interference between these modes allows us to take advantage of the larger propagation distance of the external mode while preserving the high confinement of the gap mode, resulting in nanoscale confinement of the optical field over a longer distance. The performance of the gap-plasmon transmission line is probed experimentally by recording the propagation of quantum dots luminescence over distances of more than 4 μm. We observe a 35% increase in the effective propagation length of this multimode system compared to the theoretical limit for a pure gap mode. The applicability of this simple method to nanofabricated structures is theoretically confirmed and offers a realistic way to combine longer propagation distances with lateral plasmon confinement for far field nanoscale interconnects.

  10. Ultrastretchable Analog/Digital Signal Transmission Line with Carbon Nanotube Sheets.

    Science.gov (United States)

    Lee, Yourack; Joo, Min-Kyu; Le, Viet Thong; Ovalle-Robles, Raquel; Lepró, Xavier; Lima, Márcio D; Suh, Daniel G; Yu, Han Young; Lee, Young Hee; Suh, Dongseok

    2017-08-09

    Stretchable conductors can be used in various applications depending on their own characteristics. Here, we demonstrate simple and robust elastomeric conductors that are optimized for stretchable electrical signal transmission line. They can withstand strains up to 600% without any substantial change in their resistance (≤10% as is and ≤1% with passivation), and exhibit suppressed charge fluctuations in the medium. The inherent elasticity of a polymeric rubber and the high conductivity of flexible, highly oriented carbon nanotube sheets were combined synergistically, without losing both properties. The nanoscopic strong adhesion between aligned carbon nanotube arrays and strained elastomeric polymers induces conductive wavy folds with microscopic bending of radii on the scale of a few micrometers. Such features enable practical applications such as in elastomeric length-changeable electrical digital and analog signal transmission lines at above MHz frequencies. In addition to reporting basic direct current, alternating current, and noise characterizations of the elastomeric conductors, various examples as a stretchable signal transmission line up to 600% strains are presented by confirming the capability of transmitting audio and video signals, as well as low-frequency medical signals without information distortion.

  11. Assessment of surge arrester failure rate and application studies in Hellenic high voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Christodoulou, C.A.; Fotis, G.P.; Gonos, I.F.; Stathopulos, I.A. [National Technical University of Athens, School of Electrical and Computer Engineering, High Voltage Laboratory, 9 Iroon Politechniou St., Zografou Campus, 157 80 Athens (Greece); Ekonomou, L. [A.S.PE.T.E. - School of Pedagogical and Technological Education, Department of Electrical Engineering Educators, N. Heraklion, 141 21 Athens (Greece)

    2010-02-15

    The use of transmission line surge arresters to improve the lightning performance of transmission lines is becoming more common. Especially in areas with high soil resistivity and ground flash density, surge arresters constitute the most effective protection mean. In this paper a methodology for assessing the surge arrester failure rate based on the electrogeometrical model is presented. Critical currents that exceed arresters rated energy stress were estimated by the use of a simulation tool. The methodology is applied on operating Hellenic transmission lines of 150 kV. Several case studies are analyzed by installing surge arresters on different intervals, in relation to the region's tower footing resistance and the ground flash density. The obtained results are compared with real records of outage rate showing the effectiveness of the surge arresters in the reduction of the recorded failure rate. The presented methodology can be proved valuable to the studies of electric power systems designers intending in a more effective lightning protection, reducing the operational costs and providing continuity of service. (author)

  12. Improved Fault Classification in Series Compensated Transmission Line: Comparative Evaluation of Chebyshev Neural Network Training Algorithms.

    Science.gov (United States)

    Vyas, Bhargav Y; Das, Biswarup; Maheshwari, Rudra Prakash

    2016-08-01

    This paper presents the Chebyshev neural network (ChNN) as an improved artificial intelligence technique for power system protection studies and examines the performances of two ChNN learning algorithms for fault classification of series compensated transmission line. The training algorithms are least-square Levenberg-Marquardt (LSLM) and recursive least-square algorithm with forgetting factor (RLSFF). The performances of these algorithms are assessed based on their generalization capability in relating the fault current parameters with an event of fault in the transmission line. The proposed algorithm is fast in response as it utilizes postfault samples of three phase currents measured at the relaying end corresponding to half-cycle duration only. After being trained with only a small part of the generated fault data, the algorithms have been tested over a large number of fault cases with wide variation of system and fault parameters. Based on the studies carried out in this paper, it has been found that although the RLSFF algorithm is faster for training the ChNN in the fault classification application for series compensated transmission lines, the LSLM algorithm has the best accuracy in testing. The results prove that the proposed ChNN-based method is accurate, fast, easy to design, and immune to the level of compensations. Thus, it is suitable for digital relaying applications.

  13. Fiber Bragg Grating Sensor for Fault Detection in Radial and Network Transmission Lines

    Directory of Open Access Journals (Sweden)

    Mehdi Shadaram

    2010-10-01

    Full Text Available In this paper, a fiber optic based sensor capable of fault detection in both radial and network overhead transmission power line systems is investigated. Bragg wavelength shift is used to measure the fault current and detect fault in power systems. Magnetic fields generated by currents in the overhead transmission lines cause a strain in magnetostrictive material which is then detected by Fiber Bragg Grating (FBG. The Fiber Bragg interrogator senses the reflected FBG signals, and the Bragg wavelength shift is calculated and the signals are processed. A broadband light source in the control room scans the shift in the reflected signal. Any surge in the magnetic field relates to an increased fault current at a certain location. Also, fault location can be precisely defined with an artificial neural network (ANN algorithm. This algorithm can be easily coordinated with other protective devices. It is shown that the faults in the overhead transmission line cause a detectable wavelength shift on the reflected signal of FBG and can be used to detect and classify different kind of faults. The proposed method has been extensively tested by simulation and results confirm that the proposed scheme is able to detect different kinds of fault in both radial and network system.

  14. Electromagnetic wave localization using a left-handed transmission-line superlens

    Science.gov (United States)

    Cui, Tie Jun; Cheng, Qiang; Huang, Zhi Zhong; Feng, Yijun

    2005-07-01

    We realize the localization of electromagnetic (EM) waves and energies using a left-handed transmission-line (LHTL) superlens. A detailed procedure is given to design right-handed and left-handed transmission-line media, which correspond to a vacuum and a slightly mismatched anti-vacuum, respectively. After properly designed and properly matched with terminal loads, we have generated a LHTL superlens. With the aid of microwave circuit simulations using the Agilent’s advanced design system (ADS), we show that nearly all EM fields and energies are confined in a region between two voltage sources with the same amplitude and anti-phases when they are placed at the image points of the superlens. In the simulation results, strong surface waves are clearly observed, which are consistent with the theoretical analysis of a homogeneous and slightly lossy left-handed medium superlens. Here, the slight loss is caused by the spatial dispersion of the transmission-line networks. We also show that different mismatches of the left-handed anti-vacuum will result in a different performance of the LHTL superlens, which are governed by the circuit parameters. Finally, the tolerance of circuit parameters to the energy localization is discussed.

  15. Analytical Model of Rain-Wind Induced Vibration of High-Voltage Transmission Line

    Directory of Open Access Journals (Sweden)

    Chao Zhou

    2014-10-01

    Full Text Available Under rainfall conditions, rain-wind induced vibration occurs on high-voltage transmission line occasionally. This phenomenon is caused by raindrops hitting the high-voltage conductor with a certain velocity and suspends to the bottom surface of the high-voltage conductor. By action of wind velocity and high-voltage conductor's motion, some suspended raindrops will be blown away or shaken off. The remaining water may be reformed as upper rivulet and lower rivulet. Like the effect of icing galloping, this type of vibration can cause metal fatigue on fittings and towers, while its mechanism remains unknown. The objective of this paper is to validate an analytical model of rain-wind induced vibration of the high-voltage transmission line and to investigate the effect of wind velocity, rivulet motion, raindrop velocity, and time varying mass on the vibration amplitude. Taking Tuo-chang transmission line as an example, the analytical model is solved by Galerkin weighted residual method and central difference method. The numerical results are in agreement with the experimental data available in the literature. The analytical model enables more comprehensive understanding of the rain-wind induced vibration mechanism.

  16. Characteristics of Vocal Fold Vibrations in Vocally Healthy Subjects: Analysis with Multi-Line Kymography

    Science.gov (United States)

    Yamauchi, Akihito; Imagawa, Hiroshi; Sakakibara, Ken-Ichi; Yokonishi, Hisayuki; Nito, Takaharu; Yamasoba, Tatsuya; Tayama, Niro

    2014-01-01

    Purpose: In this study, the authors aimed to analyze longitudinal data from high-speed digital images in normative subjects using multi-line kymography. Method: Vocally healthy subjects were divided into young (9 men and 17 women; M[subscript age] = 27 years) and older groups (8 men and 12 women; M[subscript age] = 73 years). From high-speed…

  17. Cryogenic electrical insulation of superconducting power transmission lines: transfer of experience learned from metal superconductors to high critical temperature superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gerhold, J. [Technical University of Graz (Austria). Inst. fuer Electrische Maschinen und Antrisbechnik; Tanaka, T. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1998-11-01

    Superconducting power transmission lines have found renewed interest after the discovery of a superconductor with high critical temperature. Cooling by liquid nitrogen instead of helium has in fact a great impact on economics. The existing wide spread knowhow about dielectric performance in helium cooled transmission lines which were already developed up to a prototype stage can be used with benefit for the design of liquid nitrogen cooled lines. (author)

  18. Design and Control of a 1-DOF MRI Compatible Pneumatically Actuated Robot with Long Transmission Lines.

    Science.gov (United States)

    Yang, Bo; Tan, U-Xuan; McMillan, Alan; Gullapalli, Rao; Desai, Jaydev P

    2011-12-01

    This paper presents the design and control of an MRI-compatible 1-DOF needle driver robot and its precise position control using pneumatic actuation with long transmission lines. MRI provides superior image quality compared to other imaging modalities such as CT or ultrasound, but imposes severe limitations on the material and actuator choice (to prevent image distortion) due to its strong magnetic field. We are primarily interested in developing a pneumatically actuated breast biopsy robot with a large force bandwidth and precise targeting capability during radio-frequency ablation (RFA) of breast tumor, and exploring the possibility of using long pneumatic transmission lines from outside the MRI room to the device in the magnet to prevent any image distortion whatsoever. This paper presents a model of the entire pneumatic system. The pneumatic lines are approximated by a first order system with time delay, because its dynamics are governed by the telegraph equation with varying coefficients and boundary conditions, which cannot be solved precisely. The slow response of long pneumatic lines and valve subsystems make position control challenging. This is further compounded by the presence of non-uniform friction in the device. Sliding mode control (SMC) was adopted, where friction was treated as an uncertainty term to drive the system onto the sliding surface. Three different controllers were designed, developed, and evaluated to achieve precise position control of the RFA probe. Experimental results revealed that all SMCs gave satisfactory performance with long transmission lines. We also performed several experiments with a 3-DOF fiber-optic force sensor attached to the needle driver to evaluate the performance of the device in the MRI under continuous imaging.

  19. Induced fields, charges and currents on a lineman engaged in transmission-line insulator washing

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Salam, M.; El-Mohandes, M.T. [Assiut Univ. (Egypt). Electrical Engineering Dept.; Alghamdi, A.S. [Junior Coll. of Technology, Jeddah (Saudi Arabia). Electrical Engineering Dept.

    1995-12-31

    This paper is aimed to calculate the distribution of the field, induced charges and currents on a lineman engaged in transmission-line insulator washing. The method of analysis is based on the charge simulation technique. The lineman is modeled by small sphere for the head and a large sphere for the body. For simplicity, the tower is chosen of the duct type and the insulator of the suspension type. The transmission-line conductor is simulated by finite and semi-infinite line charges to account for the nonuniform distribution of conductor charge resulting from the suspension insulator and the supporting tower. As the purity of the washing water is high, the water spray is simulated by a thin conducting stick extending between the column insulator and the lineman sitting on the crossarm of the tower. This represents a three-dimensional field problem and care has been devoted in the choice of the number and coordinates of charges simulating the tower, the insulator, the conductor, the water spray and the lineman. The induced currents increase as the lineman approaches the insulator with the suspended line conductor. These currents are higher than those for insulated lineman and may exceed the safe limits.

  20. Accurate Fault Location Algorithm on Power Transmission Lines With Use of Two-end Unsynchronized Measurements

    Directory of Open Access Journals (Sweden)

    DINE Mohamed

    2012-10-01

    Full Text Available This paper presents a new approach of fault location on power transmission line. This approach uses two-end unsynchronizedmeasurements of the line and uses the advantages of digital technology and numerical relaying which are available today and can easily be applied for off-line analysis. The approach is based on modifying the apparent impedance method using a very simplefirst-order formula. It is shown that the new method is independent of fault resistance, source impedances and pre-fault currents. In addition, the data volume communicated between relays issufficiently small to be easily transmitted using a digital protection channel. The proposed approach was tested via digital simulation using MATLAB. Applied test results corroborate the superiorperformance of the proposed approach.

  1. Distance protection of multiple-circuit shared tower transmission lines with different voltages

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    Multiple-circuit transmission lines combining different voltage levels in one tower present extra challenges when setting a protection philosophy, as faults between voltage levels are possible. In this study, the fault loop impedance of combined faults is compared with the fault loop impedance......-phase-to-ground faults. It is also demonstrated that the fault loop impedance of combined faults is more resistive, when compared with equivalent single-phase-to-ground faults. It is concluded that the settings used to protect a line against single-phase-to-ground faults are capable of protecting the line against...... of single-phase-to-ground faults and it is demonstrated that they are similar for high short-circuit powers; however, the fault loop impedance of a combined fault may increase substantially as the short-circuit power of the system decreases, a behaviour that is less noticeable for single...

  2. Accurate fault location algorithm on power transmission lines with use of two-end unsynchronized measurements

    Directory of Open Access Journals (Sweden)

    Mohamed Dine

    2012-01-01

    Full Text Available This paper presents a new approach to fault location on power transmission lines. This approach uses two-end unsynchronised measurements of the line and benefits from the advantages of digital technology and numerical relaying, which are available today and can easily be applied for off-line analysis. The approach is to modify the apparent impedance method using a very simple first-order formula. The new method is independent of fault resistance, source impedances and pre-fault currents. In addition, the data volume communicated between relays is sufficiently small enough to be transmitted easily using a digital protection channel. The proposed approach is tested via digital simulation using MATLand the applied test results corroborate the superior performance of the proposed approach.

  3. Study of HV Dielectrics for High Frequency Operation in Linear & Nonlinear Transmission Lines & Simulation & Development of Hybrid Nonlinear Lines for RF Generation

    Science.gov (United States)

    2015-08-27

    The high voltage diodes D5 to D10 are used to protect the HV switch against negative back swing voltage, while D4 diode for reverse current ...AFRL-AFOSR-CL-TR-2015-0001 STUDY OF HV DIELECTRICS FOR HIGH FREQUENCY OPERATION IN LINEAR & NONLINEAR TRANSMISSION LINES & SIMULATION & DEVELOPMENT...AFOSR Final Performance Report Study of HV Dielectrics for High Frequency Operation in Linear and Nonlinear Transmission Lines and Simulation

  4. Association between exposure to electromagnetic fields from high voltage transmission lines and neurobehavioral function in children.

    Directory of Open Access Journals (Sweden)

    Jiongli Huang

    Full Text Available BACKGROUND: Evidence for a possible causal relationship between exposure to electromagnetic fields (EMF emitted by high voltage transmission (HVT lines and neurobehavioral dysfunction in children is insufficient. The present study aims to investigate the association between EMF exposure from HVT lines and neurobehavioral function in children. METHODS: Two primary schools were chosen based on monitoring data of ambient electromagnetic radiation. A cross-sectional study with 437 children (9 to 13 years old was conducted. Exposure to EMF from HVT lines was monitored at each school. Information was collected on possible confounders and relevant exposure predictors using standardized questionnaires. Neurobehavioral function in children was evaluated using established computerized neurobehavioral tests. Data was analyzed using multivariable regression models adjusted for relevant confounders. RESULTS: After controlling for potential confounding factors, multivariable regression revealed that children attending a school near 500 kV HVT lines had poorer performance on the computerized neurobehavioral tests for Visual Retention and Pursuit Aiming compared to children attending a school that was not in close proximity to HVT lines. CONCLUSIONS: The results suggest long-term low-level exposure to EMF from HVT lines might have a negative impact on neurobehavioral function in children. However, because of differences in results only for two of four tests achieved statistical significance and potential limitations, more studies are needed to explore the effects of exposure to extremely low frequency EMF on neurobehavioral function and development in children.

  5. Association between exposure to electromagnetic fields from high voltage transmission lines and neurobehavioral function in children.

    Science.gov (United States)

    Huang, Jiongli; Tang, Tiantong; Hu, Guocheng; Zheng, Jing; Wang, Yuyu; Wang, Qiang; Su, Jing; Zou, Yunfeng; Peng, Xiaowu

    2013-01-01

    Evidence for a possible causal relationship between exposure to electromagnetic fields (EMF) emitted by high voltage transmission (HVT) lines and neurobehavioral dysfunction in children is insufficient. The present study aims to investigate the association between EMF exposure from HVT lines and neurobehavioral function in children. Two primary schools were chosen based on monitoring data of ambient electromagnetic radiation. A cross-sectional study with 437 children (9 to 13 years old) was conducted. Exposure to EMF from HVT lines was monitored at each school. Information was collected on possible confounders and relevant exposure predictors using standardized questionnaires. Neurobehavioral function in children was evaluated using established computerized neurobehavioral tests. Data was analyzed using multivariable regression models adjusted for relevant confounders. After controlling for potential confounding factors, multivariable regression revealed that children attending a school near 500 kV HVT lines had poorer performance on the computerized neurobehavioral tests for Visual Retention and Pursuit Aiming compared to children attending a school that was not in close proximity to HVT lines. The results suggest long-term low-level exposure to EMF from HVT lines might have a negative impact on neurobehavioral function in children. However, because of differences in results only for two of four tests achieved statistical significance and potential limitations, more studies are needed to explore the effects of exposure to extremely low frequency EMF on neurobehavioral function and development in children.

  6. Study of Lightning Outage Performance of Transmission Line by the EMTP using Grounding Resistance Model with Soil Ionization Characteristics

    Science.gov (United States)

    Ikeda, Keiichi; Furuoka, Yoshihiro; Yasuda, Yoh; Hara, Takehisa

    The EMTP is widely used for lightning surge analysis. As for transmission lines, they have studied lighting outage performance of transmission line by the EMTP. In the EMTP analysis, grounding resistance of a tower is usually modeled as a constant resistance model, however it is known that soil ionization sometimes occurs by high currents such as a lightning stroke. Therefore we have developed a grounding resistance model with soil ionization characteristics for the EMTP analysis. In this paper, we analyze an outage of an existing transmission line so that we investigate the effect of a grounding resistance model with soil ionization characteristics.

  7. Position Measurements with Micro-Channel Plates and Transmission lines using Pico-second Timing and Waveform Analysis

    CERN Document Server

    Adamsa, Bernhard; Bogdan, Mircea; Byrum, Karen; Genat, Jean-Francois C; Grabas, Herve; Frisch, Henry J; Kim, Heejong; Heintz, Mary K; Natoli, Tyler; Northrop, Richard; Oberla, Eric; Meehan, Samuel; May, Edward N; Stanek, Robert; Tang, Fukun; Varner, Gary; Yurtsev, Eugene

    2009-01-01

    The anodes of Micro-Channel Plate devices are coupled to fast transmission lines in order to reduce the number of electronics readout channels, and can provide two-dimension position measurements using two-ends delay timing. Tests with a laser and digital waveform analysis show that resolutions of a few hundreds of microns along the transmission line can be reached taking advantage of a few pico-second timing estimation. This technique is planned to be used in Micro-channel Plate devices integrating the transmission lines as anodes.

  8. Common raven occurrence in relation to energy transmission line corridors transiting human-altered sagebrush steppe

    Science.gov (United States)

    Coates, Peter S.; Howe, Kristy B.; Casazza, Michael L.; Delehanty, David J.

    2014-01-01

    Energy-related infrastructure and other human enterprises within sagebrush steppe of the American West often results in changes that promote common raven (Corvus corax; hereafter, raven) populations. Ravens, a generalist predator capable of behavioral innovation, present a threat to many species of conservation concern. We evaluate the effects of detailed features of an altered landscape on the probability of raven occurrence using extensive raven survey (n= 1045) and mapping data from southern Idaho, USA. We found nonlinear relationships between raven occurrence and distances to transmission lines, roads, and facilities. Most importantly, raven occurrence was greater with presence of transmission lines up to 2.2 km from the corridor.We further explain variation in raven occurrence along anthropogenic features based on the amount of non-native vegetation and cover type edge, such that ravens select fragmented sagebrush stands with patchy, exotic vegetative introgression. Raven occurrence also increased with greater length of edge formed by the contact of big sagebrush (Artemisia tridentate spp.) with non-native vegetation cover types. In consideration of increasing alteration of sagebrush steppe, these findings will be useful for planning energy transmission corridor placement and other management activities where conservation of sagebrush obligate species is a priority.

  9. Repetitive sub-gigawatt rf source based on gyromagnetic nonlinear transmission line

    Science.gov (United States)

    Romanchenko, Ilya V.; Rostov, Vladislav V.; Gubanov, Vladimir P.; Stepchenko, Alexey S.; Gunin, Alexander V.; Kurkan, Ivan K.

    2012-07-01

    We demonstrate a high power repetitive rf source using gyromagnetic nonlinear transmission line to produce rf oscillations. Saturated NiZn ferrites act as active nonlinear medium first sharpening the pumping high voltage nanosecond pulse and then radiating at central frequency of about 1 GHz: shock rise time excites gyromagnetic precession in ferrites forming damping rf oscillations. The optimal length of nonlinear transmission line was found to be of about 1 m. SINUS-200 high voltage driver with Tesla transformer incorporated into pulse forming line has been designed and fabricated to produce bursts of 1000 pulses with 200 Hz repetition rate. A band-pass filter and mode-converter have been designed to extract rf pulse from low-frequency component and to form TE11 mode of circular waveguide with linear polarization. A wide-band horn antenna has been fabricated to form Gaussian distribution of radiation pattern. The peak value of electric field strength of a radiated pulse at the distance of 3.5 m away from antenna is measured to be 160 kV/m. The corresponding rf peak power of 260 MW was achieved.

  10. Transmission-line resonators for the study of individual two-level tunneling systems

    Science.gov (United States)

    Brehm, Jan David; Bilmes, Alexander; Weiss, Georg; Ustinov, Alexey V.; Lisenfeld, Jürgen

    2017-09-01

    Parasitic two-level tunneling systems (TLS) emerge in amorphous dielectrics and constitute a serious nuisance for various microfabricated devices, where they act as a source of noise and decoherence. Here, we demonstrate a new test bed for the study of TLS in various materials which provides access to properties of individual TLS as well as their ensemble response. We terminate a superconducting transmission-line resonator with a capacitor that hosts TLS in its dielectric. By tuning TLS via applied mechanical strain, we observe the signatures of individual TLS strongly coupled to the resonator in its transmission characteristics and extract the coupling components of their dipole moments and energy relaxation rates. The strong and well-defined coupling to the TLS bath results in pronounced resonator frequency fluctuations and excess phase noise, through which we can study TLS ensemble effects such as spectral diffusion, and probe theoretical models of TLS interactions.

  11. Persistence of nonlinear hysteresis in fractional models of Josephson transmission lines

    Science.gov (United States)

    Macías-Díaz, J. E.

    2017-12-01

    In this note, we depart from a model describing the transmission of electric currents in Josephson-junction chains, and provide a fractional generalization using Riesz discrete differential operators. The fractional model considered has generalized Hamiltonian- and energy-like functionals. The model and the energy functionals are fully discretized in order to investigate numerically the complex dynamics of the system when a sinusoidal perturbation at one end of the chain is imposed. As one of the most important results in this report, we establish the persistence of the nonlinear phenomena of supratransmission and infratransmission in Riesz fractional chains. Nonlinear hysteresis loops are obtained numerically for some values of the order of the fractional derivative, and numerical simulations of the propagation of monochromatic wave signals through the transmission line are presented using the nonlinear bistability of the system.

  12. A NON-ISOTHERMAL THEORY FOR INTERPRETING SODIUM LINES IN TRANSMISSION SPECTRA OF EXOPLANETS

    Energy Technology Data Exchange (ETDEWEB)

    Heng, Kevin; Lavie, Baptiste [University of Bern, Physics Institute, Center for Space and Habitability, Sidlerstrasse 5, CH-3012 Bern (Switzerland); Wyttenbach, Aurélien; Ehrenreich, David; Lovis, Christophe [Observatoire de l’Université de Genève, 51 chemin des Maillettes, CH-1290 Sauverny (Switzerland); Sing, David K., E-mail: kevin.heng@csh.unibe.ch [Astrophysics Group, School of Physics, University of Exeter, Stocker Road, Exeter EX4 4QL (United Kingdom)

    2015-04-10

    We present a theory for interpreting the sodium lines detected in transmission spectra of exoplanetary atmospheres. Previous analyses employed the isothermal approximation and dealt only with the transit radius. By recognizing the absorption depth and the transit radius as being independent observables, we develop a theory for jointly interpreting both quantities, which allows us to infer the temperatures and number densities associated with the sodium lines. We are able to treat a non-isothermal situation with a constant temperature gradient. Our novel diagnostics take the form of simple-to-use algebraic formulae and require measurements of the transit radii (and their corresponding absorption depths) at line center and in the line wing for both sodium lines. We apply our diagnostics to the HARPS data of HD 189733b, confirm the upper atmospheric heating reported by Huitson et al., derive a temperature gradient of 0.4376 ± 0.0154 K km{sup −1}, and find densities ∼1–10{sup 4} cm{sup −3}.

  13. Final environmental assessment: Los Reales 115 kV transmission line alternative routes

    Energy Technology Data Exchange (ETDEWEB)

    1989-10-01

    The Central Arizona Project (CAP) was authorized as a part of the Colorado River Basin Project Act (Public Law 90-537) on September 30, 1968. The primary purpose of the CAP is to furnish water for agricultural, municipal, and industrial uses in central and southern Arizona, and western New Mexico. Due to its magnitude, the CAP is divided into several major features serving separate but interrelated functions. The Tucson Aqueduct Phase B pumping plants were designed and constructed to operate on a looped power system. The entire looped power system, including two switching stations and connecting 115-kv transmission lines, was identified in the FEIS and approved for construction in the Secretary of Interior's Record of Decision dated September 24, 1985. The loop begins in the vicinity of the Twin Peaks Pumping Plant -- the northernmost Phase B pumping station, at the Rattlesnake Switching Station. All of the looped power system has been constructed with the exception of the switching station and portion of transmission line proposed to be constructed in this project. Without construction of this final portion of the looped power system, the Phase B pumping plants will not be able to operate normally without negatively affecting nearby power sources. The CAP will also not be able to provide the reliability necessary for municipal water systems dependent upon CAP water. The purpose of this EA is to describe impacts that would result from relocating the Los Reales 115-kV transmission line, and possibly the switching station, originally identified in the FEIS. It should be mentioned the Department of Energy will complete a separate NEPA review.

  14. UAV-Based Oblique Photogrammetry for Outdoor Data Acquisition and Offsite Visual Inspection of Transmission Line

    Directory of Open Access Journals (Sweden)

    San Jiang

    2017-03-01

    Full Text Available Regular inspection of transmission lines is an essential work, which has been implemented by either labor intensive or very expensive approaches. 3D reconstruction could be an alternative solution to satisfy the need for accurate and low cost inspection. This paper exploits the use of an unmanned aerial vehicle (UAV for outdoor data acquisition and conducts accuracy assessment tests to explore potential usage for offsite inspection of transmission lines. Firstly, an oblique photogrammetric system, integrating with a cheap double-camera imaging system, an onboard dual-frequency GNSS (Global Navigation Satellite System receiver and a ground master GNSS station in fixed position, is designed to acquire images with ground resolutions better than 3 cm. Secondly, an image orientation method, considering oblique imaging geometry of the dual-camera system, is applied to detect enough tie-points to construct stable image connection in both along-track and across-track directions. To achieve the best geo-referencing accuracy and evaluate model measurement precision, signalized ground control points (GCPs and model key points have been surveyed. Finally, accuracy assessment tests, including absolute orientation precision and relative model precision, have been conducted with different GCP configurations. Experiments show that images captured by the designed photogrammetric system contain enough information of power pylons from different viewpoints. Quantitative assessment demonstrates that, with fewer GCPs for image orientation, the absolute and relative accuracies of image orientation and model measurement are better than 0.3 and 0.2 m, respectively. For regular inspection of transmission lines, the proposed solution can to some extent be an alternative method with competitive accuracy, lower operational complexity and considerable gains in economic cost.

  15. Underwater spark discharge with long transmission line for cleaning horizontal wells

    Science.gov (United States)

    Lee, Kern; Chung, Kyoung-Jae; Hwang, Y. S.; Kim, C. Y.

    2017-06-01

    A transmission line is discussed for application in an underwater spark-discharge technique in the cleaning of a horizontal well by incorporating a power-transmission model into the simulation. The pulsed-spark-discharge technique has been proposed for clogged-well rehabilitation, because it removes incrustations that are attached to well screens by using strong pressure waves that are generated by the rapid expansion of a spark channel. To apply the pulsed-spark-discharge technique to the cleaning of horizontal wells, the coaxial cable between the pulsed power supply and the spark gap as a load needs to be extended to a few hundred meters. Prior to field application, pulsed-spark-discharge experiments were conducted and the role of the transmission line was examined using an improved simulation model. In the model, a non-linear interaction of the spark channel and the capacitor bank is described by the pulse-forming action of the coaxial cable. Based on the accurate physical properties of the water plasma, such as the equation of state and electrical conductivity within the region of interest, the amount of energy contributed to the development of a shock wave was evaluated. The simulation shows that if the initial conditions of the spark channel are the same, no further reduction in strength of the pressure wave occurs, even if the cable length is increased above 50 m. Hence, the degraded peak pressure that was observed in the experiments using the longer cable is attributed to a change in the initial condition of the spark channel. The parametric study suggests that the low initial charging voltage, the high ambient water pressure, and the long cable length yield the low initial spark-channel density, which results in a reduced peak pressure. The simulation of line charging is presented to discuss the principle of disturbing the pre-breakdown process by an extended cable.

  16. METHODICAL APPROACHES TO THE CHOICE OF THE NEW GENERATION OF HIGH-VOLTAGE POWER TRANSMISSION LINE 220 kV OPTIONS

    OpenAIRE

    POSTOLATI V.M.; E. V. Bykova; SUSLOVI V.M.; SHAKARYAN Ui.G; TIMASHOVA L.V.; KAREVA S.N.

    2010-01-01

    The Transmission Power Lines of new generation are described in the article (single- compact, double-circuit compact, double-circuit Controlled Self-compensating High Voltage Transmission Power Lines (CSHVL). Basic principles of creation, design elements and comparative characteristics of the transmission lines of the new generation are described, the advantages of its are showed. Methodical approaches to the choosing of a new generation of transmission lines and facilities management FACTS a...

  17. A Flexible Load Control Strategy for Distribution Network to Reduce the Line Losses and to Eliminate the Transmission Congestion

    National Research Council Canada - National Science Library

    Beibei Wang; Xiaoqing Hu; Peifeng Shen; Wenlu Ji; Yang Cao; Jiaping Tang

    2017-01-01

    .... The existence of these factors has brought challenges to the stability of the power distribution network, as well as increasing the risk of exceeding transmission capacity of distribution lines...

  18. Impacts of transmission lines on birds in flight: proceedings of a workshop

    Science.gov (United States)

    Avery, Michael L.

    1978-01-01

    Progress to alleviate the national and world energy problem will come as individual issues are identified and acceptable solutions implemented. One of the specific issues to emerge in the last few years in the United States is the impact of electric power transmission lines on birds in flight. Therefore, the National Power Plant Team, Office of Biological Services, U.S. Fish and Wildlife Service, requested Oak Ridge Associated Universities (ORAU) to organized and convene a workshop of knowledgeable experts to examine this issue and options for dealing with it. The participants are listed at the end of this report.

  19. Multiresolution Time-Domain Analysis of Multiconductor Transmission Lines Terminated in Linear Loads

    Directory of Open Access Journals (Sweden)

    Zongliang Tong

    2017-01-01

    Full Text Available This paper derives a multiresolution time-domain (MRTD scheme for the multiconductor transmission line (MTL equations based on Daubechies’ scaling functions. The terminations are characterized by a state-variable formulation which allows a general description of the termination networks. For the linear load terminations, a method incorporating the terminal constraints is proposed to work out the scheme at and close to the terminations. The MRTD scheme is implemented with different basis functions for linear components including resistances, inductances, and capacitances. Numerical results show that the MRTD schemes obtain a more stable result than the conventional finite difference time-domain (FDTD method with a coarse space step.

  20. Two-Port Representation of a Linear Transmission Line in the Time Domain.

    Science.gov (United States)

    1980-01-01

    rational approximation to Yo(s). 20 .9 7 - IRRATIONAL FUNCTION x PRONY FIT .4 .3 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 TIME (Pas) Figure 1...cables, the Prony fits were found to a time of 60 lis. The computation of the source terms was done in the frequency domain and inverse Fourier transformed...Transmission Line Dependent Parameters Prony 20e ABSTRACT (’Contlnue on reverse #ido If necessary end Identify by block number) The linear section of a

  1. Steady State Analysis of a UPFC as Voltage Regulator for Optimal Position in the Transmission Line

    Directory of Open Access Journals (Sweden)

    S. Ali Al-Mawsawi

    2003-06-01

    Full Text Available It has recently been illustrated that the Unified Power Flow Controller (UPFC installation location plays an important role in effecting nonlinearly in the UPFC steady state performance of the system. A Pulse Width Modulation (PWM based on UPFC as a voltage regulator is modeled and analyzed to investigate the optimal position in the transmission line. From the study made in this paper, it is shown that the location of UPFC plays a significant part in effecting nonlinearly. It is also found from the simulation results that the distribution of the active and reactive power flows can be controlled by varying the modulation index of the device.

  2. Electromagnetic Field Interaction With Transmission Lines From Classical Theory to HF Radiation Effects

    CERN Document Server

    Tkachenko, Sergey V

    2008-01-01

    The evaluation of the electromagnetic field coupling to transmission lines is an important problem in electromagnetic compatibility. The unabated increase in the operating frequency of electronic products and the emergence of sources of disturbances with higher frequency content (such as High Power Microwave and Ultra-Wide Band systems) have led to a breakdown of the TL approximation's basic assumptions for a number of applications. In the last decade or so, the generalization of the TL theory to take into account high frequency effects has emerged as an important topic of study in electromagn

  3. Autonomous Inspection Robot for Power Transmission Lines Maintenance While Operating on the Overhead Ground Wires

    OpenAIRE

    Zheng Li; Yi Ruan

    2011-01-01

    This paper describes the development of a mobile robot capable of clearing such obstacles as counterweights, anchor clamps, and torsion tower. The mobile robot walks on overhead ground wires in 500KV power tower. Its ultimate purpose is to automate to inspect the defect of power transmission line. The robot with 13 motors is composed of two arms, two wheels, two claws, two wrists, etc. Each arm has 4 degree of freedom. Claws are also mounted on the arms. An embedded computer based on PC/104 i...

  4. A Miniaturized 4 : 1 Unequal Wilkinson Power Divider Using Artificial Transmission Lines and Double-Sided Parallel-Strip Lines

    Directory of Open Access Journals (Sweden)

    Wen Huang

    2017-01-01

    Full Text Available A 4 : 1 unequal Wilkinson power divider using microstrip artificial transmission lines (ATLs is proposed. For the ATL, a series of meandered-line inductors, parallel-plate capacitors, and interdigital capacitors are employed. The designed power divider is composed of three ATLs, and a method has been proposed using technology of ATLs and double-sided parallel-strip lines (DSPSLs to design line of high characteristic impedance. Microstrip line with very high characteristic impedance of over 150 Ω has been achieved by this method, which cannot be easily achieved by conventional transmission lines because of comparably thin conductor width. The fabricated 4 : 1 unequal power divider has good operational performance and occupies 55.3 mm×37.8 mm, which is only about 40% of area compared to a conventional one at 0.9 GHz.

  5. Multi-line transmission in medical imaging using the second-harmonic signal.

    Science.gov (United States)

    Prieur, Fabrice; Dénarié, Bastien; Austeng, Andreas; Torp, Hans

    2013-12-01

    The emergence of three-dimensional imaging in the field of medical ultrasound imaging has greatly increased the number of transmissions needed to insonify a whole volume. With a large number of transmissions comes a low image frame rate. When using classical transmission techniques, as in two-dimensional imaging, the frame rate becomes unacceptably low, prompting the use of alternative transmission patterns that require less time. One alternative is to use a multi-line transmission (MLT) technique which consists of transmitting several pulses simultaneously in different directions. Perturbations appear when acquiring and beamforming the signal in the direction of one pulse because of the pulses sent in other directions. The edge waves from the pulses transmitted in a different direction add to the signal transmitted in the direction of interest, resulting in artifacts in the final image. Taking advantage of the nonlinear propagation of sound in tissue, the second-harmonic signal can be used with the MLT technique. The image obtained using the second-harmonic signal, compared with an image obtained using the fundamental signal, should have reduced artifacts coming from other pulses transmitted simultaneously. Simulations, backed up by experiments imaging a wire target and an in vivo left ventricle, confirm that the hypothesis is valid. In the studied case, the perturbations appear as an increase in the signal level around the main echo of a point scatterer. When using the fundamental signal, the measured amplitude level of the perturbations was approximately -40 dB compared with the maximum signal amplitude (-27 dB in vivo), whereas it was around -60 dB (-45 dB in vivo) for the second-harmonic signal. The MLT technique encounters limitations in the very near field where the pulses overlap and the perturbation level also increases for images with strong speckle and low contrast.

  6. Raptor code-enabled reliable data transmission for in-vehicle power line communication systems with impulsive noise

    OpenAIRE

    Xu, Zhaopeng; Yang, Chuanchuan; Tan, Zhongwei; Sheng, Zhengguo

    2017-01-01

    With the rapid development of in-vehicle data transmission systems, the power line communication (PLC) technology is considered as a good alternative due to the reduction of cable harness. However, PLC suffers from severe impulse noise which hinders the correct reception of data packets and hence leads to a poor transmission performance. In this paper, we propose a raptor code-enabled data transmission scheme for different traffic classes in in-vehicle PLC systems. Simulation results show tha...

  7. Mosquito cell lines: history, isolation, availability and application to assess the threat of arboviral transmission in the United Kingdom.

    Science.gov (United States)

    Walker, Thomas; Jeffries, Claire L; Mansfield, Karen L; Johnson, Nicholas

    2014-08-20

    Mosquitoes are highly effective vectors for transmission of human and animal pathogens. Understanding the relationship between pathogen and vector is vital in developing strategies to predict and prevent transmission. Cell lines derived from appropriate mosquito hosts provide a relatively simple tool for investigating the interaction between the host and viruses transmitted by mosquitoes. This review provides a brief overview of the development of mosquito cell lines, methods of isolation, their availability and application for investigating insect-virus interactions.

  8. Design of a Broadband Band-Pass Filter with Notch-Band Using New Models of Coupled Transmission Lines

    OpenAIRE

    Navid Daryasafar; Somaye Baghbani; Mohammad Naser Moghaddasi; Ramezanali Sadeghzade

    2014-01-01

    We intend to design a broadband band-pass filter with notch-band, which uses coupled transmission lines in the structure, using new models of coupled transmission lines. In order to realize and present the new model, first, previous models will be simulated in the ADS program. Then, according to the change of their equations and consequently change of basic parameters of these models, optimization and dependency among these parameters and also their frequency response are attended and results...

  9. Real-time transmission of pediatric echocardiograms using a single ISDN line.

    Science.gov (United States)

    Milazzo, Angelo S; Herlong, J René; Li, Jennifer S; Sanders, Stephen P; Barrington, Mary; Bengur, A Resai

    2002-09-01

    We tested the adequacy of a videoconferencing system using a single integrated systems digital network (ISDN) line (128 kilobits per second) for the remote diagnosis of children with suspected congenital heart disease (CHD). Real-time echocardiogram interpretation was compared to subsequent videotape review in 401 studies with concordance in 383 (95.5%) studies. A new diagnosis of CHD was made in 98 studies. Immediate patient transfer was arranged based upon a real-time diagnosis in five studies. In 300 studies, a normal diagnosis obviated further evaluation. A single ISDN line is adequate for transmission of pediatric echocardiograms and it allows for remote management of patients with CHD. Copyright 2002 Elsevier Science Ltd.

  10. Medium frequency propagation characteristics of different transmission lines in an underground coal mine.

    Science.gov (United States)

    Li, Jingcheng; Waynert, Joseph A; Whisner, Bruce G

    A medium frequency (MF) communication system operating in an underground coal mine couples its signals to a long conductor, which acts as an MF transmission line (TL) in a tunnel to permit communications among transceivers along the line. The TL is generally the longest signal path for the system, and its propagation characteristics will have a major impact on the performance of the MF communication system. In this study, the propagation characteristics of three types of MF TLs in two layouts-on the roof and on the floor of a coal mine tunnel-were obtained in an effort to understand the propagation characteristics of different TLs in different locations. The study confirmed a low MF signal loss on all of these TLs. The study also found that the TLs in different layouts had substantially different propagation characteristics. The propagation characteristics of these different TLs in different layouts are presented in the paper.

  11. A Comparative Parametric Analysis of the Ground Fault Current Distribution on Overhead Transmission Lines

    Directory of Open Access Journals (Sweden)

    VINTAN, M.

    2016-02-01

    Full Text Available The ground fault current distribution in an effectively grounded power network is affected by various factors, such as: tower footing impedances, spans lengths, configuration and parameters of overhead ground wires and power conductors, soil resistivity etc. In this paper, we comparatively analyze, using different models, the ground fault current distribution in a single circuit transmission line with one ground wire. A parametric comparative analysis was done in order to study the effects of the non-uniformity of the towers footing impedances, number of power lines spans, soil resistivity, grounding systems resistances of the terminal substations etc., on the ground fault current distribution. There are presented some useful qualitative and quantitative results obtained through a complex dedicated developed MATLAB 7.0 program.

  12. African HVDC system world's largest. [533 kV, 1440 km transmission line

    Energy Technology Data Exchange (ETDEWEB)

    1977-04-15

    Africa now has an HVDC transmission system whose design is unique in some respects. It operates at the highest dc voltage ever utilized, stretches across a longer distance than any other dc line, and will ultimately deliver more power than any similar project yet anticipated. The HVDC line 1,440 km long, transmits the bulk of the output of the Cabora Bassa hydro complex now being developed on the Zambezi River in Mozambique. There, an underground powerplant has been constructed that will generate 2,000 MW when its final stage of development is completed in early 1979. This figure can later be doubled by construction of a sister powerplant at the same dam. In the near future, nearly all the Cabora Bassa output will be exported to the Republic of South Africa.

  13. Multiband Slot-Based Dual Composite Right/Left-Handed Transmission Line

    Directory of Open Access Journals (Sweden)

    E. Abdo-Sanchez

    2012-10-01

    Full Text Available A dual Composite Right-/Left-Handed Transmission Line (CRLH TL implementation that presents multiband behaviour is proposed in this contribution. The artificial TL is realized by loading a host microstrip line with alternate rectangular stubs and slots. The required series and shunt immittances are respectively provided by the slot and the stub. Due to the distributed nature of these immittances, the resultant phase response presents theoretically infinite RH and LH alternate bands, thus being appropriate for multiband applications. The design methodology is described with the help of a proposed TLs-based equivalent circuit and highlights the simplicity for balance condition. Full wave simulated results of the dispersion characteristics and frequency response of a unit-cell and a three-cells structure are presented.

  14. Summit-Watertown transmission line project, South Dakota. Final Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-01

    The Western Area Power Administration (Western) needs to rebuild the existing Summit-Watertown 115-kV transmission line, located in northeastern South Dakota, and western Minnesota. Nearly 60 percent of the existing facility was replaced in 1965 after severe ice-loading broke structures and wires. Because of the extensive loss of the line, surplus poles had to be used to replace the damaged H-frame structures. These were of varying sizes, causing improper structure loading. Additionally, the conductors and overhead shield wires have been spliced in numerous places. This provides additional space on these wires for icing and wind resistance, which in turn create problems for reliability. Finally, a progressive fungal condition has weakened the poles and, along with the improper loading, has created an unsafe condition for maintenance personnel and the general public.

  15. Features of transmission at analog intermediate frequency signals on fiber – optical communication lines in radar station.

    Science.gov (United States)

    Filatov, D. L.; Galichina, A. A.; Vysoczky, M. G.; Yalunina, T. R.; Davydov, V. V.; Rud’, V. Yu

    2017-11-01

    Features of transmission at analog intermediate frequency signals on fiber – optical communication lines are considered. In view of these features the technique for check of developed optical transmission systems at analog intermediate frequency signals is offered. The results of experimental investigations are presented.

  16. 41 CFR 102-75.380 - May power transmission lines and rights-of-way be disposed of in other ways?

    Science.gov (United States)

    2010-07-01

    ... REGULATION REAL PROPERTY 75-REAL PROPERTY DISPOSAL Surplus Real Property Disposal Power Transmission Lines § 102-75.380 May power transmission lines and rights-of-way be disposed of in other ways? Yes, power transmission lines and rights-of-way not disposed of by sale for fair market value may be disposed of following...

  17. 78 FR 9358 - Dairyland Power Cooperative: CapX 2020 Hampton-Rochester-La Crosse 345-kV Transmission Line Proposal

    Science.gov (United States)

    2013-02-08

    ... Transmission Line Proposal AGENCY: Rural Utilities Service, USDA. ACTION: Notice of Availability of a Record of... Cooperative (Dairyland) for its share in the construction of a proposed 345- kilovolt (kV) transmission line... necessary. The proposal includes construction and operation of a 345-kV transmission line and associated...

  18. Resilience of electricity grids against transmission line overloads under wind power injection at different nodes.

    Science.gov (United States)

    Schiel, Christoph; Lind, Pedro G; Maass, Philipp

    2017-09-14

    A steadily increasing fraction of renewable energy sources for electricity production requires a better understanding of how stochastic power generation affects the stability of electricity grids. Here, we assess the resilience of an IEEE test grid against single transmission line overloads under wind power injection based on the dc power flow equations and a quasi-static grid response to wind fluctuations. Thereby we focus on the mutual influence of wind power generation at different nodes. We find that overload probabilities vary strongly between different pairs of nodes and become highly affected by spatial correlations of wind fluctuations. An unexpected behaviour is uncovered: for a large number of node pairs, increasing wind power injection at one node can increase the power threshold at the other node with respect to line overloads in the grid. We find that this seemingly paradoxical behaviour is related to the topological distance of the overloaded line from the shortest path connecting the wind nodes. In the considered test grid, it occurs for all node pairs, where the overloaded line belongs to the shortest path.

  19. Secure and Time-Aware Communication of Wireless Sensors Monitoring Overhead Transmission Lines.

    Science.gov (United States)

    Mazur, Katarzyna; Wydra, Michal; Ksiezopolski, Bogdan

    2017-07-11

    Existing transmission power grids suffer from high maintenance costs and scalability issues along with a lack of effective and secure system monitoring. To address these problems, we propose to use Wireless Sensor Networks (WSNs) as a technology to achieve energy efficient, reliable, and low-cost remote monitoring of transmission grids. With WSNs, smart grid enables both utilities and customers to monitor, predict and manage energy usage effectively and react to possible power grid disturbances in a timely manner. However, the increased application of WSNs also introduces new security challenges, especially related to privacy, connectivity, and security management, repeatedly causing unpredicted expenditures. Monitoring the status of the power system, a large amount of sensors generates massive amount of sensitive data. In order to build an effective Wireless Sensor Network (WSN) for a smart grid, we focus on designing a methodology of efficient and secure delivery of the data measured on transmission lines. We perform a set of simulations, in which we examine different routing algorithms, security mechanisms and WSN deployments in order to select the parameters that will not affect the delivery time but fulfill their role and ensure security at the same time. Furthermore, we analyze the optimal placement of direct wireless links, aiming at minimizing time delays, balancing network performance and decreasing deployment costs.

  20. Secure and Time-Aware Communication of Wireless Sensors Monitoring Overhead Transmission Lines

    Science.gov (United States)

    Mazur, Katarzyna; Wydra, Michal; Ksiezopolski, Bogdan

    2017-01-01

    Existing transmission power grids suffer from high maintenance costs and scalability issues along with a lack of effective and secure system monitoring. To address these problems, we propose to use Wireless Sensor Networks (WSNs)as a technology to achieve energy efficient, reliable, and low-cost remote monitoring of transmission grids. With WSNs, smart grid enables both utilities and customers to monitor, predict and manage energy usage effectively and react to possible power grid disturbances in a timely manner. However, the increased application of WSNs also introduces new security challenges, especially related to privacy, connectivity, and security management, repeatedly causing unpredicted expenditures. Monitoring the status of the power system, a large amount of sensors generates massive amount of sensitive data. In order to build an effective Wireless Sensor Networks (WSNs) for a smart grid, we focus on designing a methodology of efficient and secure delivery of the data measured on transmission lines. We perform a set of simulations, in which we examine different routing algorithms, security mechanisms and WSN deployments in order to select the parameters that will not affect the delivery time but fulfill their role and ensure security at the same time. Furthermore, we analyze the optimal placement of direct wireless links, aiming at minimizing time delays, balancing network performance and decreasing deployment costs. PMID:28696390

  1. Secure and Time-Aware Communication of Wireless Sensors Monitoring Overhead Transmission Lines

    Directory of Open Access Journals (Sweden)

    Katarzyna Mazur

    2017-07-01

    Full Text Available Existing transmission power grids suffer from high maintenance costs and scalability issues along with a lack of effective and secure system monitoring. To address these problems, we propose to use Wireless Sensor Networks (WSNs as a technology to achieve energy efficient, reliable, and low-cost remote monitoring of transmission grids. With WSNs, smart grid enables both utilities and customers to monitor, predict and manage energy usage effectively and react to possible power grid disturbances in a timely manner. However, the increased application of WSNs also introduces new security challenges, especially related to privacy, connectivity, and security management, repeatedly causing unpredicted expenditures. Monitoring the status of the power system, a large amount of sensors generates massive amount of sensitive data. In order to build an effective Wireless Sensor Network (WSN for a smart grid, we focus on designing a methodology of efficient and secure delivery of the data measured on transmission lines. We perform a set of simulations, in which we examine different routing algorithms, security mechanisms and WSN deployments in order to select the parameters that will not affect the delivery time but fulfill their role and ensure security at the same time. Furthermore, we analyze the optimal placement of direct wireless links, aiming at minimizing time delays, balancing network performance and decreasing deployment costs.

  2. Comparing Longitudinal Coupling and Temporal Delay in a Transmission-Line Model of the Cochlea

    Science.gov (United States)

    Homer, Martin; Szalai, Robert; Champneys, Alan; Epp, Bastian

    2011-11-01

    In this paper we compare and contrast the effects of longitudinal coupling and temporal delay on a fluid-structure transmission-line model of the mammalian cochlea. This work is based on recent reports that, in order to qualitatively explain experimental data, models of the basilar membrane impedance must include an exponential term that represents a time-delayed feedback. There are also models that include, e.g., a spatial feed-forward mechanism, whose solution is often approximated by replacing the feed-forward coupling by an exponential term. We show that there is no direct equivalence between the time-delay and the longitudinal coupling mechanisms, although qualitatively similar results can be achieved, albeit in very different regions of parameter space. An investigation of the steady-state outputs shows that both models can display sharp tuning, but that the time-delay model requires negative damping for such an effect to occur. Conversely, the longitudinal coupling model provides the most promising results with small positive damping. These results are extended by a careful stability analysis. We find that, whereas a small time delay can stabilize an unstable transmission-line model (with negative damping), that the longitudinal coupling model is stable when the damping is positive. The techniques developed in the paper are directed towards a more comprehensive analysis of nonlinear models.

  3. Transmission-Line Readout with Good Time and Space Resolutions for Planacon MCP-PMTs

    CERN Document Server

    Tang, F; Byrum, K; Drake, G; Ertley, C; Frisch, H; Genat, J-F; May, E

    2008-01-01

    With commercially-available multi-anode microchannel plate photomultiplier tubes (MCP-PMT) and electronics, resolutions significantly better than 10 psec have been achieved in small systems with a few readout channels[1,2]. For large-scale time-of-flight systems used in particle physics, which may cover tens of square meters, a solution must be found with a manageable number of electronics channels and low total power consumption on the readout electronics without degrading the system timing resolution. We present here the design of a transmission-line readout for a Photonis Planacon MCP-PMT that has these characteristics. The tube, which is 5 cm square, is characterized by signal pulse rise times in the order of 200 psec and transit time spreads (TTS) in the order of 25 psec[1, 2]. The model 85011-011 MCP has 1024 anode pads laid out in an array of 32 by 32 on the back of the tube. The proposed readout is implemented on a Rogers 4350B printed circuit board with 32 parallel 50-ohm transmission lines on 1.6 mm...

  4. A novel structure of transmission line pulse transformer with mutually coupled windings.

    Science.gov (United States)

    Yu, Binxiong; Su, Jiancang; Li, Rui; Zhao, Liang; Zhang, Xibo; Wang, Junjie

    2014-03-01

    A novel structure of transmission line transformer (TLT) with mutually coupled windings is described in this paper. All transmission lines except the first stage of the transformer are wound on a common ferrite core for the TLT with this structure. A referral method was introduced to analyze the TLT with this structure, and an analytic expression of the step response was derived. It is shown that a TLT with this structure has a significantly slower droop rate than a TLT with other winding structures and the number of ferrite cores needed is largely reduced. A four-stage TLT with this structure was developed, whose input and output impedance were 4.2 Ω and 67.7 Ω, respectively. A frequency response test of the TLT was carried out. The test results showed that pulse response time of the TLT is several nanoseconds. The TLT described in this paper has the potential to be used as a rectangle pulse transformer with very fast response time.

  5. High sensitive FBG load cell for icing of overhead transmission lines

    Science.gov (United States)

    Mao, Naiqiang; Ma, Guoming; Li, Chengrong; Li, Yabo; Shi, Cheng; Du, Yue

    2017-04-01

    Heavy ice coating of overhead transmission lines created the serious threat on the safe operation of power grid. The measurement of conductor icing had been an effective and reliable methods to prevent potential risks, such as conductor breakage, insulator flashover and tower collapse. Because of the advantages of immunity to electromagnetic interference and no demand for power supply in site, the optical load cell has been widely applied in monitoring the ice coating of overhead transmission lines. In this paper, we have adopted the shearing structure with additional grooves as elastic element of load cell to detect the eccentric load. Then, two welding package fiber Bragg gratings (FBGs) were mounted onto the grooves of elastic element with a direction deviation of 90° to eliminate temperature effects on strain measurement without extra FBG. After that, to avoid the occurrence of load cell breakage in heavy load measurement, the protection part has been proposed and added to the elastic element. The results of tension experiments indicate that the resolution of the load cell is 7.78 N in the conventional measuring range (0-10 kN). And in addition, the load cell proposed in this paper also has a good performance in actual experiment in which the load and temperature change simultaneously.

  6. Accurate measurement of the localization properties of electric transmission lines using the overlap amplitude

    Science.gov (United States)

    Lazo, Edmundo

    2017-06-01

    We determine the localization properties of classic direct electric transmission lines by means of the overlap amplitude. The amplitude is defined as C i,j ω = 2| I i ω I j ω |, where I i ω is the electric current in the ith cell of the transmission line for the state with frequency ω. This definition is motivated by the concurrence C i,j α = 2| φ i α φ j α |, which is a quantum correlation measure (pairwise entanglement). We distribute the inductances L j according to three non-linear models: (a) the slowly varying potential model; (b) the Aubry-André model and (c) the Soukoulis-Economou model. The results show that the average of the powers of the overlap amplitude ⟨( C i,j ω )2 q ⟩ and its scaling properties may accurately characterize the localization behavior of these non-linear models. Moreover, the overlap amplitude can be used to determine the mobility edge of some non-periodic models.

  7. Plasma evolution and dynamics in high-power vacuum-transmission-line post-hole convolutes

    Directory of Open Access Journals (Sweden)

    D. V. Rose

    2008-06-01

    Full Text Available Vacuum-post-hole convolutes are used in pulsed high-power generators to join several magnetically insulated transmission lines (MITL in parallel. Such convolutes add the output currents of the MITLs, and deliver the combined current to a single MITL that, in turn, delivers the current to a load. Magnetic insulation of electron flow, established upstream of the convolute region, is lost at the convolute due to symmetry breaking and the formation of magnetic nulls, resulting in some current losses. At very high-power operating levels and long pulse durations, the expansion of electrode plasmas into the MITL of such devices is considered likely. This work examines the evolution and dynamics of cathode plasmas in the double-post-hole convolutes used on the Z accelerator [R. B. Spielman et al., Phys. Plasmas 5, 2105 (1998PHPAEN1070-664X10.1063/1.872881]. Three-dimensional particle-in-cell (PIC simulations that model the entire radial extent of the Z accelerator convolute—from the parallel-plate transmission-line power feeds to the z-pinch load region—are used to determine electron losses in the convolute. The results of the simulations demonstrate that significant current losses (1.5 MA out of a total system current of 18.5 MA, which are comparable to the losses observed experimentally, could be caused by the expansion of cathode plasmas in the convolute regions.

  8. Active Power Flow Optimization of Industrial Power Supply with Regard to the Transmission Line Conductor Heating

    Directory of Open Access Journals (Sweden)

    Leyzgold D.Yu.

    2015-04-01

    Full Text Available This article studies the problem of the transmission line conductor heating effect on the active power flows optimization in the local segment of industrial power supply. The purpose is to determine the optimal generation rating of the distributed power sources, in which the power flow values will correspond to the minimum active power losses in the power supply. The timeliness is the need to define the most appropriate rated power values of distributed sources which will be connected to current industrial power supply. Basing on the model of active power flow optimization, authors formulate the description of the nonlinear transportation problem considering the active power losses depending on the transmission line conductor heating. Authors proposed a new approach to the heating model parameters definition based on allowable current loads and nominal parameters of conductors as part of the optimization problem. Analysis of study results showed that, despite the relatively small active power losses reduction to the tune 0,45% due to accounting of the conductors heating effect for the present configuration of power supply, there are significant fluctuations in the required generation rating in nodes of the network to 9,32% within seasonal changes in the outer air temperature. This fact should be taken into account when selecting the optimum power of distributed generation systems, as exemplified by an arbitrary network configuration.

  9. Inductive intrinsic localized modes in a one-dimensional nonlinear electric transmission line.

    Science.gov (United States)

    Sato, M; Mukaide, T; Nakaguchi, T; Sievers, A J

    2016-07-01

    The experimental properties of intrinsic localized modes (ILMs) have long been compared with theoretical dynamical lattice models that make use of nonlinear onsite and/or nearest-neighbor intersite potentials. Here it is shown for a one-dimensional lumped electrical transmission line that a nonlinear inductive component in an otherwise linear parallel capacitor lattice makes possible a new kind of ILM outside the plane wave spectrum. To simplify the analysis, the nonlinear inductive current equations are transformed to flux transmission line equations with analog onsite hard potential nonlinearities. Approximate analytic results compare favorably with those obtained from a driven damped lattice model and with eigenvalue simulations. For this mono-element lattice, ILMs above the top of the plane wave spectrum are the result. We find that the current ILM is spatially compressed relative to the corresponding flux ILM. Finally, this study makes the connection between the dynamics of mass and force constant defects in the harmonic lattice and ILMs in a strongly anharmonic lattice.

  10. Preliminary investigation of an improved metal-dielectric cathode for magnetically insulated transmission line oscillator.

    Science.gov (United States)

    Zhang, Xiaoping; Dang, Fangchao; Zhang, Jun; Fan, Yuwei; Li, Zhiqiang

    2015-02-01

    In order to explore the cathode with good repetition quality for the magnetically insulated transmission line oscillators, an improved metal-dielectric cathode is proposed and investigated experimentally. The cathode is designed to be step-like shape, and thin copper plated boards are periodically and compactly arrayed on the surface of the cathode base, which ensures the uniformity of the electrons emitted from the cusps of the copper plated boards. According to the numerical simulation results, the step-like shape is beneficial to convert the kinetic energy of the magnetic insulating current partially and enhance the beam-wave interaction efficiency. Finally, a preliminary experiment of an L-band magnetically insulated transmission line oscillator (MILO) with the improved metal-dielectric cathode is carried out. A high power microwave (HPM) with an average power of 1.95 GW is generated from the MILO, with an efficiency of 13.5%. Under the same experiment condition, the output power and main frequency with the presented cathode are almost the same to those with the velvet cathode. Apart from that, metal-dielectric cathode has the merits of small outgassing and long lifetime, and all of these make the improved metal-dielectric cathode significantly promising for the MILO repetition operation.

  11. Dual-transmission line modeling of electrochemical processes in polyaniline-cellulose ester composite porous membranes.

    Science.gov (United States)

    Qaiser, Asif A

    2014-08-14

    The charge transport processes in polyaniline (PANI) composite porous membranes have been elaborated in this study using dual-transmission line impedance model conventionally used for macroscopically homogeneous (nanoporous) membranes. Mixed cellulose ester (ME)-PANI porous membranes were prepared using various in situ chemical polymerization techniques including solution- and vapor-phase polymerizations, and two-compartment cell diaphragmatic polymerization. Each technique yielded different PANI deposition site and content in the membranes. As a result, the modeling of electrochemical impedance spectroscopy (EIS) data yielded different model parameters that have been correlated with the PANI content and deposition site (i.e., surface layering versus in-bulk deposition) in the membranes. The modeling results showed that PANI deposition enhanced charge transport by shifting the interfacial transfer mechanism at pore walls from simple double layer charging to the charge transfer involving oxidation of PANI molecular chains deposited at the pore walls of the composite membranes. In addition, in-bulk PANI deposition in the membranes by means of two-compartment cell polymerization showed several orders of magnitude faster charge transport as compared to the membranes where PANI deposited only at the surface. This study shows that pore-controlled diffusion in PANI composite porous membranes can be satisfactorily modeled using dual-transmission line model and correlated with PANI deposition site in the membranes.

  12. Research on the correlation between corona current spectrum and audible noise spectrum of HVDC transmission line

    Science.gov (United States)

    Liu, Yingyi; Zhou, Lijuan; Liu, Yuanqing; Yuan, Haiwen; Ji, Liang

    2017-11-01

    Audible noise is closely related to corona current on a high voltage direct current (HVDC) transmission line. In this paper, we measured a large amount of audible noise and corona current waveforms simultaneously based on the largest outdoor HVDC corona cage all over the world. By analyzing the experimental data, the related statistical regularities between a corona current spectrum and an audible noise spectrum were obtained. Furthermore, the generation mechanism of audible noise was analyzed theoretically, and the related mathematical expression between the audible noise spectrum and the corona current spectrum, which is suitable for all of these measuring points in the space, has been established based on the electro-acoustic conversion theory. Finally, combined with the obtained mathematical relation, the internal reasons for these statistical regularities appearing in measured corona current and audible noise data were explained. The results of this paper not only present the statistical association regularities between the corona current spectrum and the audible noise spectrum on a HVDC transmission line, but also reveal the inherent reasons of these associated rules.

  13. Cryogenic Fiber Optic Sensors for Superconducting Magnets and Power Transmission Lines in High Energy Physics Applications

    CERN Document Server

    AUTHOR|(CDS)2081689; Bajko, Marta

    In the framework of the Luminosity upgrade of the Large Hadron Collider (HL - LHC), a remarkable R&D effort is now ongoing at the European Organization for Nuclear Research (CERN) in order to develop a new generation of accelerator magnets and superconducting power transmission lines. The magnet technology will be based on Nb3Sn enabling to operate in the 11 - 13 T range. In parallel, in order to preserve the power converters from the increasing radiation level, high power transmission lines are foreseen to feed the magnets from free - radiation zones. These will be based on high temperature superconductors cooled down with helium gas in the range 5 - 30 K. The new technologies will require advanced design and fabrication approaches as well as adapted instrumentation for monitoring both the R&D phase and operation. Resistive sensors have been used so far for voltage, temperature and strain monitoring but their integration still suffers from the number of electrical wires and the complex compensation o...

  14. The effect of grounding system modeling on lightning-related studies of transmission lines

    Directory of Open Access Journals (Sweden)

    Reza Shariatinasab

    2017-12-01

    Full Text Available Un-accurate modeling of power system may cause to under or over-design the insulation, which in turn, leads to increase in the investment and/or maintenance cost of the network protection against lightning overvoltages. The grounding system is an effective parameter on the magnitude of the lightning overvoltages and insulation coordination of high voltage transmission lines (TLs. This paper presents a comprehensive evaluation of the effect of grounding electrode impedance on the estimation of overvoltages caused by lightning strokes, in which both the vertical and non-vertical strokes are considered. In the presented study, static and wide-band model of the tower-footing grounding system is adopted assuming the soil electrical parameters to be either constant or frequency dependent. Also, the effect of modeling type of grounding system is considered on the TLs’ reliability indices. The study was performed on a typical 400-kV transmission line which is modeled in EMTP-RV. From the simulation results, it is found that the outage rate of TLs is markedly affected by the model of the tower footing grounding system. This effect is more pronounced when the soil electrical parameters are frequency dependent. It is also concluded that, in addition to the lightning overvoltages, the unavailability of the TLs is significantly affected by wide-band model of grounding system, non-vertical lightning strokes and soil resistivity.

  15. Support vector machine based fault classification and location of a long transmission line

    Directory of Open Access Journals (Sweden)

    Papia Ray

    2016-09-01

    Full Text Available This paper investigates support vector machine based fault type and distance estimation scheme in a long transmission line. The planned technique uses post fault single cycle current waveform and pre-processing of the samples is done by wavelet packet transform. Energy and entropy are obtained from the decomposed coefficients and feature matrix is prepared. Then the redundant features from the matrix are taken out by the forward feature selection method and normalized. Test and train data are developed by taking into consideration variables of a simulation situation like fault type, resistance path, inception angle, and distance. In this paper 10 different types of short circuit fault are analyzed. The test data are examined by support vector machine whose parameters are optimized by particle swarm optimization method. The anticipated method is checked on a 400 kV, 300 km long transmission line with voltage source at both the ends. Two cases were examined with the proposed method. The first one is fault very near to both the source end (front and rear and the second one is support vector machine with and without optimized parameter. Simulation result indicates that the anticipated method for fault classification gives high accuracy (99.21% and least fault distance estimation error (0.29%.

  16. A transmission line model for propagation in elliptical core optical fibers

    Energy Technology Data Exchange (ETDEWEB)

    Georgantzos, E.; Boucouvalas, A. C. [Department of Telecommunications and Informatics, University of Peloponnese, Karaiskaki 70, 221 00, Tripoli Greece (Greece); Papageorgiou, C. [Department of Electrical Engineering, National technical University of Athens, Iroon Politechniou 9, Kaisariani, 16121, Athens (Greece)

    2015-12-31

    The calculation of mode propagation constants of elliptical core fibers has been the purpose of extended research leading to many notable methods, with the classic step index solution based on Mathieu functions. This paper seeks to derive a new innovative method for the determination of mode propagation constants in single mode fibers with elliptic core by modeling the elliptical fiber as a series of connected coupled transmission line elements. We develop a matrix formulation of the transmission line and the resonance of the circuits is used to calculate the mode propagation constants. The technique, used with success in the case of cylindrical fibers, is now being extended for the case of fibers with elliptical cross section. The advantage of this approach is that it is very well suited to be able to calculate the mode dispersion of arbitrary refractive index profile elliptical waveguides. The analysis begins with the deployment Maxwell’s equations adjusted for elliptical coordinates. Further algebraic analysis leads to a set of equations where we are faced with the appearance of harmonics. Taking into consideration predefined fixed number of harmonics simplifies the problem and enables the use of the resonant circuits approach. According to each case, programs have been created in Matlab, providing with a series of results (mode propagation constants) that are further compared with corresponding results from the ready known Mathieu functions method.

  17. Commissioning of the 28 GHz ECRH power transmission line for the TJ-II stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Martínez-Fernández, J., E-mail: jose.martinez@ciemat.es [Laboratorio Nacional de Fusión (LNF), Centro de Investigaciones Tecnológicas, Medioambientales y Tecnológicas (CIEMAT), Av/Complutense 40, 28040 Madrid (Spain); Cappa, Á. [Laboratorio Nacional de Fusión (LNF), Centro de Investigaciones Tecnológicas, Medioambientales y Tecnológicas (CIEMAT), Av/Complutense 40, 28040 Madrid (Spain); Chirkov, A. [Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod (Russian Federation); Ros, A.; Tolkachev, A.; Catalán, G.; Soleto, A.; Redondo, M. [Laboratorio Nacional de Fusión (LNF), Centro de Investigaciones Tecnológicas, Medioambientales y Tecnológicas (CIEMAT), Av/Complutense 40, 28040 Madrid (Spain); Doane, J.L.; Anderson, J.P. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States)

    2015-10-15

    Highlights: • The 28 GHz power transmission line of the TJ-II stellarator is described. • Mismatch and alignment problems are covered, presenting infrared measurements. • Beam distortion in the matching optics unit led to unwanted modes in the waveguide. • After a redesign distortion was eliminated and coupling maximized. • Final measurements suggest finer alignment must be performed. - Abstract: The commissioning of the 28 GHz power transmission line of the TJ-II stellarator, designed for the excitation of electron Bernstein waves (EBW) through the O-X-B mode conversion process, is presented in this paper. Based upon a comprehensive set of thermal measurements, its purpose is to go into details about the several problems that arouse during the whole process, namely higher order modes excitation because of the wider beam size and alignment mismatches at the waveguide mouth. All these drawbacks may have prevented the correct O-X mode conversion, thus providing a reasonable explanation for the unsuccessful EBW heating experiments.

  18. Dynamic Response of Underground Circular Lining Tunnels Subjected to Incident P Waves

    Directory of Open Access Journals (Sweden)

    Hua Xu

    2014-01-01

    Full Text Available Dynamic stress concentration in tunnels and underground structures during earthquakes often leads to serious structural damage. A series solution of wave equation for dynamic response of underground circular lining tunnels subjected to incident plane P waves is presented by Fourier-Bessel series expansion method in this paper. The deformation and stress fields of the whole medium of surrounding rock and tunnel were obtained by solving the equations of seismic wave propagation in an elastic half space. Based on the assumption of a large circular arc, a series of solutions for dynamic stress were deduced by using a wave function expansion approach for a circular lining tunnel in an elastic half space rock medium subjected to incident plane P waves. Then, the dynamic response of the circular lining tunnel was obtained by solving a series of algebraic equations after imposing its boundary conditions for displacement and stress of the circular lining tunnel. The effects of different factors on circular lining rock tunnels, including incident frequency, incident angle, buried depth, rock conditions, and lining stiffness, were derived and several application examples are presented. The results may provide a good reference for studies on the dynamic response and aseismic design of tunnels and underground structures.

  19. Impact of SSSC on Measured Impedance in Single Phase to Ground Fault Condition on 220 kV Transmission Line

    Directory of Open Access Journals (Sweden)

    Mohamed ZELLAGUI

    2012-08-01

    Full Text Available This paper presents and compares the impact of SSSC on measured impedance for single phase to ground fault condition. The presence of Static Synchronous SSSC on a transmission line has a great influence on the ZRelay in distance protection. The protection of the high voltage 220 kV single circuit transmission line in eastern Algerian electrical transmission networks is affected in the case with resistance fault RF. The paper investigate the effect of Static Synchronous Series Compensator (SSSC on the measured impedance (Relay taking into account the distance fault point (n and fault resistance (RF. The resultants simulation is performed in MATLAB software environment.

  20. Distance Protection Impedance Measurement for Inhomogeneous Multiple-Circuit 400/150 kV Transmission Lines with Shared Towers

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Sigurbjörnsson, Ragnar; Bukh, Bjarne

    2016-01-01

    Combined transmission lines where different voltage levels shares same towers are used in transmission systems in order to save way of right. Faults between different voltage levels results in complex fault current distributions due to mutual couplings and the fact that the faulted phases no longer...... impedance for combined faults and thereby shed light on relay trips. This study uses actual fault records, analytical method and PSCAD simulation studies to analyse combined faults in an existing 400 and 150 kV transmission line owned by Danish TSO Energinet.dk. The results clearly show that an accurate...