WorldWideScience

Sample records for subject headings mesh

  1. Mapping of medical acronyms and initialisms to Medical Subject Headings (MeSH) across selected systems.

    Science.gov (United States)

    Shultz, Mary

    2006-10-01

    Given the common use of acronyms and initialisms in the health sciences, searchers may be entering these abbreviated terms rather than full phrases when searching online systems. The purpose of this study is to evaluate how various MEDLINE Medical Subject Headings (MeSH) interfaces map acronyms and initialisms to the MeSH vocabulary. The interfaces used in this study were: the PubMed MeSH database, the PubMed Automatic Term Mapping feature, the NLM Gateway Term Finder, and Ovid MEDLINE. Acronyms and initialisms were randomly selected from 2 print sources. The test data set included 415 randomly selected acronyms and initialisms whose related meanings were found to be MeSH terms. Each acronym and initialism was entered into each MEDLINE MeSH interface to determine if it mapped to the corresponding MeSH term. Separately, 46 commonly used acronyms and initialisms were tested. While performance differed widely, the success rates were low across all interfaces for the randomly selected terms. The common acronyms and initialisms tested at higher success rates across the interfaces, but the differences between the interfaces remained. Online interfaces do not always map medical acronyms and initialisms to their corresponding MeSH phrases. This may lead to inaccurate results and missed information if acronyms and initialisms are used in search strategies.

  2. Medical Subject Heading (MeSH) annotations illuminate maize genetics and evolution.

    Science.gov (United States)

    Beissinger, Timothy M; Morota, Gota

    2017-01-01

    High-density marker panels and/or whole-genome sequencing, coupled with advanced phenotyping pipelines and sophisticated statistical methods, have dramatically increased our ability to generate lists of candidate genes or regions that are putatively associated with phenotypes or processes of interest. However, the speed with which we can validate genes, or even make reasonable biological interpretations about the principles underlying them, has not kept pace. A promising approach that runs parallel to explicitly validating individual genes is analyzing a set of genes together and assessing the biological similarities among them. This is often achieved via gene ontology analysis, a powerful tool that involves evaluating publicly available gene annotations. However, additional resources such as Medical Subject Headings (MeSH) can also be used to evaluate sets of genes to make biological interpretations. In this manuscript, we describe utilizing MeSH terms to make biological interpretations in maize. MeSH terms are assigned to PubMed-indexed manuscripts by the National Library of Medicine, and can be directly mapped to genes to develop gene annotations. Once mapped, these terms can be evaluated for enrichment in sets of genes or similarity between gene sets to provide biological insights. Here, we implement MeSH analyses in five maize datasets to demonstrate how MeSH can be leveraged by the maize and broader crop-genomics community. We demonstrate that MeSH terms can be effectively leveraged to generate hypotheses and make biological interpretations in maize, and we provide a pipeline that enables the use of MeSH terms in other plant species.

  3. Redefining the pharmacology and pharmacy subject category in the journal citation reports using medical subject headings (MeSH).

    Science.gov (United States)

    Minguet, Fernando; Salgado, Teresa M; Santopadre, Claudio; Fernandez-Llimos, Fernando

    2017-10-01

    Background The Journal Citation Reports (JCR) Pharmacology and Pharmacy subject category is heterogeneous. The inclusion of journals with basic and clinical scopes, which have different citation patterns, compromises comparability of impact factors among journals within the category. Objective To subdivide the Pharmacology and Pharmacy category into basic pharmacology, clinical pharmacology, and pharmacy based on the analyses of Medical Subject Headings (MeSH) as a proxy of journals' scopes. Setting JCR. Method All articles, and respective MeSH, published in 2013, 2014, and 2015 in all journals included in the 2014 JCR Pharmacology and Pharmacy category were retrieved from PubMed. Several models using a combination of the 14 MeSH categories and specific MeSH tree branches were tested using hierarchical cluster analysis. Main outcome measure Distribution of journals across the subcategories of the JCR Pharmacology and Pharmacy subject category. Results A total of 107,847 articles from 214 journals were included. Nine different models combining the MeSH categories M (Persons) and N (Health Care) with specific MeSH tree branches (selected ad-hoc) and Pharmacy-specific MeSH (identified in previous research) consistently grouped 142 journals (66.4%) in homogeneous groups reflecting their basic and clinical pharmacology, and pharmacy scopes. Ultimately, journals were clustered into: 150 in basic pharmacology, 43 in clinical pharmacology, 16 in basic pharmacology and clinical pharmacology, and 5 in pharmacy. Conclusion The reformulation of the Pharmacology and Pharmacy category into three categories was demonstrated by the consistent results obtained from testing nine different clustering models using the MeSH terms assigned to their articles.

  4. Citation analysis with medical subject Headings (MeSH) using the Web of Knowledge: A new routine

    NARCIS (Netherlands)

    Leydesdorff, L.; Opthof, T.

    2013-01-01

    Citation analysis of documents retrieved from the Medline database (at the Web of Knowledge) has been possible only on a case-by-case basis. A technique is presented here for citation analysis in batch mode using both Medical Subject Headings (MeSH) at the Web of Knowledge and the Science Citation

  5. Quality of pharmacy-specific Medical Subject Headings (MeSH) assignment in pharmacy journals indexed in MEDLINE.

    Science.gov (United States)

    Minguet, Fernando; Salgado, Teresa M; van den Boogerd, Lucienne; Fernandez-Llimos, Fernando

    2015-01-01

    The Medical Subject Headings (MeSH) is the National Library of Medicine (NLM) controlled vocabulary for indexing articles. Inaccuracies in the MeSH thesaurus have been reported for several areas including pharmacy. To assess the quality of pharmacy-specific MeSH assignment to articles indexed in pharmacy journals. The 10 journals containing the highest number of articles published in 2012 indexed under the MeSH 'Pharmacists' were identified. All articles published over a 5-year period (2008-2012) in the 10 previously selected journals were retrieved from PubMed. MeSH terms used to index these articles were extracted and pharmacy-specific MeSH terms were identified. The frequency of use of pharmacy-specific MeSH terms was calculated across journals. A total of 6989 articles were retrieved from the 10 pharmacy journals, of which 328 (4.7%) were articles not fully indexed and therefore did not contain any MeSH terms assigned. Among the 6661 articles fully indexed, the mean number of MeSH terms was 10.1 (SD = 4.0), being 1.0 (SD = 1.3) considered as Major MeSH. Both values significantly varied across journals. The mean number of pharmacy-specific MeSH terms per article was 0.9 (SD = 1.2). A total of 3490 (52.4%) of the 6661 articles were indexed in pharmacy journals without a single pharmacy-specific MeSH. Of the total 67193 MeSH terms assigned to articles, on average 10.5% (SD = 13.9) were pharmacy-specific MeSH. A statistically significant different pattern of pharmacy-specific MeSH assignment was identified across journals (Kruskal-Wallis P MeSH terms to articles indexed in pharmacy journals can be improved to further enhance evidence gathering in pharmacy. Over half of the articles published in the top-10 journals publishing pharmacy literature were indexed without a single pharmacy-specific MeSH. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Two Similarity Metrics for Medical Subject Headings (MeSH): An Aid to Biomedical Text Mining and Author Name Disambiguation.

    Science.gov (United States)

    Smalheiser, Neil R; Bonifield, Gary

    2016-04-06

    In the present paper, we have created and characterized several similarity metrics for relating any two Medical Subject Headings (MeSH terms) to each other. The article-based metric measures the tendency of two MeSH terms to appear in the MEDLINE record of the same article. The author-based metric measures the tendency of two MeSH terms to appear in the body of articles written by the same individual (using the 2009 Author-ity author name disambiguation dataset as a gold standard). The two metrics are only modestly correlated with each other (r = 0.50), indicating that they capture different aspects of term usage. The article-based metric provides a measure of semantic relatedness, and MeSH term pairs that co-occur more often than expected by chance may reflect relations between the two terms. In contrast, the author metric is indicative of how individuals practice science, and may have value for author name disambiguation and studies of scientific discovery. We have calculated article metrics for all MeSH terms appearing in at least 25 articles in MEDLINE (as of 2014) and author metrics for MeSH terms published as of 2009. The dataset is freely available for download and can be queried at http://arrowsmith.psych.uic.edu/arrowsmith_uic/mesh_pair_metrics.html. Handling editor: Elizabeth Workman, MLIS, PhD.

  7. Bibliometric Perspectives on Medical Innovation using the Medical Subject Headings (MeSH) of PubMed

    CERN Document Server

    Leydesdorff, Loet; Rafols, Ismael

    2012-01-01

    Multiple perspectives on the nonlinear processes of medical innovations can be distinguished and combined using the Medical Subject Headings (MeSH) of the Medline database. Focusing on three main branches-"diseases," "drugs and chemicals," and "techniques and equipment"-we use base maps and overlay techniques to investigate the translations and interactions and thus to gain a bibliometric perspective on the dynamics of medical innovations. To this end, we first analyze the Medline database, the MeSH index tree, and the various options for a static mapping from different perspectives and at different levels of aggregation. Following a specific innovation (RNA interference) over time, the notion of a trajectory which leaves a signature in the database is elaborated. Can the detailed index terms describing the dynamics of research be used to predict the diffusion dynamics of research results? Possibilities are specified for further integration between the Medline database, on the one hand, and the Science Citati...

  8. Cited References and Medical Subject Headings (MeSH) as Two Different Knowledge Representations : Clustering and Mappings at the Paper Level

    NARCIS (Netherlands)

    Leydesdorff, L.; Comins, J.A.; Sorensen, A.A.; Bornmann, L.; Hellsten, I.

    2016-01-01

    For the biomedical sciences, the Medical Subject Headings (MeSH) make available a rich feature which cannot currently be merged properly with widely used citing/cited data. Here, we provide methods and routines that make MeSH terms amenable to broader usage in the study of science indicators: using

  9. Medical Subject Headings (MeSH) for indexing and retrieving open-source healthcare data.

    Science.gov (United States)

    Marc, David T; Khairat, Saif S

    2014-01-01

    The US federal government initiated the Open Government Directive where federal agencies are required to publish high value datasets so that they are available to the public. Data.gov and the community site Healthdata.gov were initiated to disperse such datasets. However, data searches and retrieval for these sites are keyword driven and severely limited in performance. The purpose of this paper is to address the issue of extracting relevant open-source data by proposing a method of adopting the MeSH framework for indexing and data retrieval. A pilot study was conducted to compare the performance of traditional keywords to MeSH terms for retrieving relevant open-source datasets related to "mortality". The MeSH framework resulted in greater sensitivity with comparable specificity to the keyword search. MeSH showed promise as a method for indexing and retrieving data, yet future research should conduct a larger scale evaluation of the performance of the MeSH framework for retrieving relevant open-source healthcare datasets.

  10. Using MeSH (medical subject headings) to enhance PubMed search strategies for evidence-based practice in physical therapy.

    Science.gov (United States)

    Richter, Randy R; Austin, Tricia M

    2012-01-01

    Evidence-based practice (EBP) is an important paradigm in health care. Physical therapists report lack of knowledge and time constraints as barriers to EBP. The purpose of this technical report is to illustrate how Medical Subject Headings (MeSH), a controlled vocabulary thesaurus of indexing terms, is used to efficiently search MEDLINE, the largest component of PubMed. Using clinical questions, this report illustrates how search terms common to physical therapist practice do or do not map to appropriate MeSH terms. A PubMed search strategy that takes advantage of text words and MeSH terms is provided. A search of 139 terms and 13 acronyms was conducted to determine whether they appropriately mapped to a MeSH term. The search results were categorized into 1 of 5 outcomes. Nearly half (66/139) of the search terms mapped to an appropriate MeSH term (outcome 1). When a search term did not appropriately map to a MeSH term, it was entered into the MeSH database to search for an appropriate MeSH term. Twenty-one appropriate MeSH terms were found (outcomes 2 and 4), and there were 52 search terms for which an appropriate MeSH term was not found (outcomes 3 and 5). Nearly half of the acronyms did not map to an appropriate MeSH term, and an appropriate MeSH term was not found in the database. The results are based on a limited number of search terms and acronyms. Understanding how search terms map to MeSH terms and using the PubMed search strategy can enable physical therapists to take full advantage of available MeSH terms and should result in more-efficient and better-informed searches.

  11. Three-Way Catalog Division Combined with Conversion to Medical Subject Headings (MeSH) in a Medium-sized Medical Library *†

    Science.gov (United States)

    McNutt, Eleanor M.; Poland, Ursula H.

    1974-01-01

    Conversion to MeSH and other reasons are enumerated for the division of an undivided dictionary card catalog into a three-way divided catalog, consisting of Proper Names, Titles, and Topical Subjects sections. Methodology of division is described. Conversion from Library of Congress Subject Headings to Medical Subject Headings (MeSH) as an authority list stimulated such concurrent changes as (1) the introduction of a guide card system that eliminates typing of subject headings on catalog cards and (2) the adoption of a filing system that employs reverse chronological order for all types of sequential material in the Proper Names and Titles sections and for all material in the Topical Subjects section. The ancillary decisions, procedures, and methods necessitated by these major conversions are also described. PMID:4462686

  12. Cited references and Medical Subject Headings (MeSH) as two different knowledge representations: clustering and mappings at the paper level.

    Science.gov (United States)

    Leydesdorff, Loet; Comins, Jordan A; Sorensen, Aaron A; Bornmann, Lutz; Hellsten, Iina

    2016-01-01

    For the biomedical sciences, the Medical Subject Headings (MeSH) make available a rich feature which cannot currently be merged properly with widely used citing/cited data. Here, we provide methods and routines that make MeSH terms amenable to broader usage in the study of science indicators: using Web-of-Science (WoS) data, one can generate the matrix of citing versus cited documents; using PubMed/MEDLINE data, a matrix of the citing documents versus MeSH terms can be generated analogously. The two matrices can also be reorganized into a 2-mode matrix of MeSH terms versus cited references. Using the abbreviated journal names in the references, one can, for example, address the question whether MeSH terms can be used as an alternative to WoS Subject Categories for the purpose of normalizing citation data. We explore the applicability of the routines in the case of a research program about the amyloid cascade hypothesis in Alzheimer's disease. One conclusion is that referenced journals provide archival structures, whereas MeSH terms indicate mainly variation (including novelty) at the research front. Furthermore, we explore the option of using the citing/cited matrix for main-path analysis as a by-product of the software.

  13. Global visibility for global health: Is it time for a new descriptor in Medical Subject Heading (MeSH of MEDLINE/PubMed?

    Directory of Open Access Journals (Sweden)

    Ana Marušic´

    2013-06-01

    Full Text Available Despite a large body of research in global health (almost 9000 articles published in PubMed until 2012, the term “global health” is not included in the Medical Subject Headings (MeSH of the NLM – its controlled vocabulary thesaurus which NLM uses to index articles in MEDL INE. There are only 6 journals currently covered by PubMed which specialize in global health, including Journal of Global Health.

  14. Transforming the Medical Subject Headings into Linked Data: Creating the Authorized Version of MeSH in RDF.

    Science.gov (United States)

    Bushman, Barbara; Anderson, David; Fu, Gang

    In February 2014 the National Library of Medicine formed the Linked Data Infrastructure Working Group to investigate the potential for publishing linked data, determine best practices for publishing linked data, and prioritize linked data projects, beginning with transforming the Medical Subject Headings as a linked data pilot. This article will review the pilot project to convert the Medical Subject Headings from XML to RDF. It will discuss the collaborative process, the technical and organizational issues tackled, and the future of linked data at the library.

  15. Citation Analysis using the Medline Database at the Web of Knowledge: Searching "Times Cited" with Medical Subject Headings (MeSH)

    CERN Document Server

    Leydesdorff, Loet

    2012-01-01

    Citation analysis of documents retrieved from the Medline database (at the Web of Knowledge) has been possible only on a case-by-case basis. A technique is here developed for citation analysis in batch mode using both Medical Subject Headings (MeSH) at the Web of Knowledge and the Science Citation Index at the Web of Science. This freeware routine is applied to the case of "Brugada Syndrome," a specific disease and field of research (since 1992). The journals containing these publications are attributed to Web-of-Science Categories other than "Cardiac and Cardiovascular Systems"), perhaps because of the possibility of genetic testing for this syndrome in the clinic. With this routine, all the instruments available for citation analysis can be used on the basis of MeSH terms.

  16. Use of NLM medical subject headings with the MeSH2010 thesaurus in the PORTAL-DOORS system.

    Science.gov (United States)

    Taswell, Carl

    2010-01-01

    The NLM MeSH Thesaurus has been incorporated for use in the PORTAL-DOORS System (PDS) for resource metadata management on the semantic web. All 25588 descriptor records from the NLM 2010 MeSH Thesaurus have been exposed as web accessible resources by the PDS MeSH2010 Thesaurus implemented as a PDS PORTAL Registry operating as a RESTful web service. Examples of records from the PDS MeSH2010 PORTAL are demonstrated along with their use by records in other PDS PORTAL Registries that reference the concepts from the MeSH2010 Thesaurus. Use of this important biomedical terminology will greatly enhance the quality of metadata content of other PDS records thus improving cross-domain searches between different problem oriented domains and amongst different clinical specialty fields.

  17. A data mining approach to selecting herbs with similar efficacy: Targeted selection methods based on medical subject headings (MeSH).

    Science.gov (United States)

    Yea, Sang-Jun; Seong, BoSeok; Jang, Yunji; Kim, Chul

    2016-04-22

    Natural products have long been the most important source of ingredients in the discovery of new drugs. Moreover, since the Nagoya Protocol, finding alternative herbs with similar efficacy in traditional medicine has become a very important issue. Although random selection is a common method of finding ethno-medicinal herbs of similar efficacy, it proved to be less effective; therefore, this paper proposes a novel targeted selection method using data mining approaches in the MEDLINE database in order to identify and select herbs with a similar degree of efficacy. From among sixteen categories of medical subject headings (MeSH) descriptors, three categories containing terms related to herbal compounds, efficacy, toxicity, and the metabolic process were selected. In order to select herbs of similar efficacy in a targeted way, we adopted the similarity measurement method based on MeSH. In order to evaluate the proposed algorithm, we built up three different validation datasets which contain lists of original herbs and corresponding medicinal herbs of similar efficacy. The average area under curve (AUC) of the proposed algorithm was found to be about 500% larger than the random selection method. We found that the proposed algorithm puts more hits at the front of the top-10 list than the random selection method, and precisely discerns the efficacy of the herbs. It was also found that the AUC of the experiments either remained the same or increased slightly in all three validation datasets as the search range was increased. This study reveals and proves that the proposed algorithm is significantly more accurate and efficient in finding alternative herbs of similar efficacy than the random selection method. As such, it is hoped that this approach will be used in diverse applications in the ethno-pharmacology field. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  18. MeSHSim: An R/Bioconductor package for measuring semantic similarity over MeSH headings and MEDLINE documents.

    Science.gov (United States)

    Zhou, Jing; Shui, Yuxuan; Peng, Shengwen; Li, Xuhui; Mamitsuka, Hiroshi; Zhu, Shanfeng

    2015-12-01

    Currently, all MEDLINE documents are indexed by medical subject headings (MeSH). Computing semantic similarity between two MeSH headings as well as two documents has become very important for many biomedical text mining applications. We develop an R package, MeSHSim, which can compute nine similarity measures between MeSH nodes, by which similarity between MeSH headings as well as MEDLINE documents can be easily computed. Also, MeSHSim supports querying hierarchy information of a MeSH heading and retrieving MeSH headings of a query document, and can be easily integrated into pipelines for any biomedical text analysis tasks. MeSHSim is released under general public license (GPL), and available through Bioconductor and from Github at https://github.com/JingZhou2015/MeSHSim.

  19. Characterization of the Medical Subject Headings thesaurus for pharmacy.

    Science.gov (United States)

    Minguet, Fernando; Van Den Boogerd, Lucienne; Salgado, Teresa M; Correr, Cassyano J; Fernandez-Llimos, Fernando

    2014-11-15

    The completeness and utility of pharmacy-oriented Medical Subject Headings (MeSH) relative to MeSH terminology pertaining to other healthcare professions (dentistry and nursing) are evaluated. The 2013 version of the MeSH thesaurus-the standard vocabulary used by the National Library of Medicine (NLM) to index articles in PubMed and MEDLINE-was searched for dentistry-, nursing-, and pharmacy-specific terms using a truncation strategy (search terms: nurs*, dent*, and pharm*); the hierarchical level of each term and the number of descendant terms (an indication of the granularity of the associated NLM-indexed content) were determined. PubMed searches were conducted to identify areas of the MeSH hierarchy containing dentistry- and nursing-specific terms but no equivalent pharmacy-specific term. The search of the MeSH thesaurus identified 145 terms representing dentistry-specific activities and 94 and 26 terms specific to nursing and pharmacy practice, respectively. Analysis of the three sets of MeSH terms indicated that dentistry-oriented MeSH terms were generally situated more prominently within the MeSH hierarchy than terms for nursing- and pharmacy-oriented research; the MeSH terminology oriented toward nursing or dentistry practice was relatively more granular, allowing for increased specificity and power of information retrieval during PubMed and MEDLINE searches. Seventeen proposed new MeSH terms describing key areas of pharmacy practice were identified; the inclusion of these terms in the MeSH hierarchy could substantially expand and improve the retrievability of NLM-indexed literature. Imbalances and gaps were found in MeSH coverage of pharmacy concepts and terminology relative to MeSH terminology specific to the nursing and dentistry professions. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  20. Accuracy of medical subject heading indexing of dental survival analyses.

    Science.gov (United States)

    Layton, Danielle M; Clarke, Michael

    2014-01-01

    To assess the Medical Subject Headings (MeSH) indexing of articles that employed time-to-event analyses to report outcomes of dental treatment in patients. Articles published in 2008 in 50 dental journals with the highest impact factors were hand searched to identify articles reporting dental treatment outcomes over time in human subjects with time-to-event statistics (included, n = 95), without time-to-event statistics (active controls, n = 91), and all other articles (passive controls, n = 6,769). The search was systematic (kappa 0.92 for screening, 0.86 for eligibility). Outcome-, statistic- and time-related MeSH were identified, and differences in allocation between groups were analyzed with chi-square and Fischer exact statistics. The most frequently allocated MeSH for included and active control articles were "dental restoration failure" (77% and 52%, respectively) and "treatment outcome" (54% and 48%, respectively). Outcome MeSH was similar between these groups (86% and 77%, respectively) and significantly greater than passive controls (10%, P indexed as such. Significantly more time-related MeSH were allocated to the included than the active controls (92% and 79%, respectively, P = .02), or to the passive controls (22%, P < .001). MeSH allocation within MEDLINE to time-to-event dental articles was inaccurate and inconsistent. Statistical MeSH were omitted from 30% of the included articles and incorrectly allocated to 15% of active controls. Such errors adversely impact search accuracy.

  1. Using Topic Models to Interpret MEDLINE's Medical Subject Headings

    Science.gov (United States)

    Newman, David; Karimi, Sarvnaz; Cavedon, Lawrence

    We consider the task of interpreting and understanding a taxonomy of classification terms applied to documents in a collection. In particular, we show how unsupervised topic models are useful for interpreting and understanding MeSH, the Medical Subject Headings applied to articles in MEDLINE. We introduce the resampled author model, which captures some of the advantages of both the topic model and the author-topic model. We demonstrate how topic models complement and add to the information conveyed in a traditional listing and description of a subject heading hierarchy.

  2. Developing a biomedical expert finding system using medical subject headings.

    Science.gov (United States)

    Singh, Harpreet; Singh, Reema; Malhotra, Arjun; Kaur, Manjit

    2013-12-01

    Efficient identification of subject experts or expert communities is vital for the growth of any organization. Most of the available expert finding systems are based on self-nomination, which can be biased, and are unable to rank experts. Thus, the objective of this work was to develop a robust and unbiased expert finding system which can quantitatively measure expertise. Medical Subject Headings (MeSH) is a controlled vocabulary developed by the National Library of Medicine (NLM) for indexing research publications, articles and books. Using the MeSH terms associated with peer-reviewed articles published from India and indexed in PubMed, we developed a Web-based program which can be used to identify subject experts and subjects associated with an expert. We have extensively tested our system to identify experts from India in various subjects. The system provides a ranked list of experts where known experts rank at the top of the list. The system is general; since it uses information available with the PubMed, it can be implemented for any country. The expert finding system is able to successfully identify subject experts in India. Our system is unique because it allows the quantification of subject expertise, thus enabling the ranking of experts. Our system is based on peer-reviewed information. Use of MeSH terms as subjects has standardized the subject terminology. The system matches requirements of an ideal expert finding system.

  3. Searching the literature using medical subject headings versus text word with PubMed.

    Science.gov (United States)

    Chang, Angela A; Heskett, Karen M; Davidson, Terence M

    2006-02-01

    This study was conducted to investigate the performance of two search strategies in the retrieval of information from the National Library of Medicine (NLM) on otolaryngology-head and neck surgery related conditions and diagnoses using PubMed. Two search strategies-one based on the use of Medical Subject Headings (MeSH) and the second based on text word searching-were compared. The MeSH search provided a more efficient search than the text word search. Head and neck surgeons can most efficiently search the NLM using PubMed as a search engine by initiating the search with MeSH terms. Once a key article is identified, the searcher should use the "Related Articles" feature.

  4. Bibliometric perspectives on medical innovation using the medical subject headings of PubMed

    NARCIS (Netherlands)

    Leydesdorff, L.; Rotolo, D.; Rafols, I.

    2012-01-01

    Multiple perspectives on the nonlinear processes of medical innovations can be distinguished and combined using the Medical Subject Headings (MeSH) of the MEDLINE database. Focusing on three main branches—"diseases," "drugs and chemicals," and "techniques and equipment"—we use base maps and overlay

  5. A case study: using social tagging to engage students in learning Medical Subject Headings*

    Science.gov (United States)

    Bresnahan, Megan; Flynn, David B.; Harzbecker, Joseph; Blanchard, Mary; Ginn, David

    2009-01-01

    In exploring new ways of teaching students how to use Medical Subject Headings (MeSH), librarians at Boston University's Alumni Medical Library (AML) integrated social tagging into their instruction. These activities were incorporated into the two-credit graduate course, “GMS MS 640: Introduction to Biomedical Information,” required for all students in the graduate medical science program. Hands-on assignments and in-class exercises enabled librarians to present MeSH and the concept of a controlled vocabulary in a familiar and relevant context for the course's Generation Y student population and provided students the opportunity to actively participate in creating their education. At the conclusion of these activities, students were surveyed regarding the clarity of the presentation of the MeSH vocabulary. Analysis of survey responses indicated that 46% found the concept of MeSH to be the clearest concept presented in the in-class intervention. PMID:19404497

  6. Improving information retrieval using Medical Subject Headings Concepts: a test case on rare and chronic diseases.

    Science.gov (United States)

    Darmoni, Stéfan J; Soualmia, Lina F; Letord, Catherine; Jaulent, Marie-Christine; Griffon, Nicolas; Thirion, Benoît; Névéol, Aurélie

    2012-07-01

    As more scientific work is published, it is important to improve access to the biomedical literature. Since 2000, when Medical Subject Headings (MeSH) Concepts were introduced, the MeSH Thesaurus has been concept based. Nevertheless, information retrieval is still performed at the MeSH Descriptor or Supplementary Concept level. The study assesses the benefit of using MeSH Concepts for indexing and information retrieval. Three sets of queries were built for thirty-two rare diseases and twenty-two chronic diseases: (1) using PubMed Automatic Term Mapping (ATM), (2) using Catalog and Index of French-language Health Internet (CISMeF) ATM, and (3) extrapolating the MEDLINE citations that should be indexed with a MeSH Concept. Type 3 queries retrieve significantly fewer results than type 1 or type 2 queries (about 18,000 citations versus 200,000 for rare diseases; about 300,000 citations versus 2,000,000 for chronic diseases). CISMeF ATM also provides better precision than PubMed ATM for both disease categories. Using MeSH Concept indexing instead of ATM is theoretically possible to improve retrieval performance with the current indexing policy. However, using MeSH Concept information retrieval and indexing rules would be a fundamentally better approach. These modifications have already been implemented in the CISMeF search engine.

  7. Atlas-Based Automatic Generation of Subject-Specific Finite Element Tongue Meshes.

    Science.gov (United States)

    Bijar, Ahmad; Rohan, Pierre-Yves; Perrier, Pascal; Payan, Yohan

    2016-01-01

    Generation of subject-specific 3D finite element (FE) models requires the processing of numerous medical images in order to precisely extract geometrical information about subject-specific anatomy. This processing remains extremely challenging. To overcome this difficulty, we present an automatic atlas-based method that generates subject-specific FE meshes via a 3D registration guided by Magnetic Resonance images. The method extracts a 3D transformation by registering the atlas' volume image to the subject's one, and establishes a one-to-one correspondence between the two volumes. The 3D transformation field deforms the atlas' mesh to generate the subject-specific FE mesh. To preserve the quality of the subject-specific mesh, a diffeomorphic non-rigid registration based on B-spline free-form deformations is used, which guarantees a non-folding and one-to-one transformation. Two evaluations of the method are provided. First, a publicly available CT-database is used to assess the capability to accurately capture the complexity of each subject-specific Lung's geometry. Second, FE tongue meshes are generated for two healthy volunteers and two patients suffering from tongue cancer using MR images. It is shown that the method generates an appropriate representation of the subject-specific geometry while preserving the quality of the FE meshes for subsequent FE analysis. To demonstrate the importance of our method in a clinical context, a subject-specific mesh is used to simulate tongue's biomechanical response to the activation of an important tongue muscle, before and after cancer surgery.

  8. Leveraging output term co-occurrence frequencies and latent associations in predicting medical subject headings.

    Science.gov (United States)

    Kavuluru, Ramakanth; Lu, Yuan

    2014-11-01

    Trained indexers at the National Library of Medicine (NLM) manually tag each biomedical abstract with the most suitable terms from the Medical Subject Headings (MeSH) terminology to be indexed by their PubMed information system. MeSH has over 26,000 terms and indexers look at each article's full text while assigning the terms. Recent automated attempts focused on using the article title and abstract text to identify MeSH terms for the corresponding article. Most of these approaches used supervised machine learning techniques that use already indexed articles and the corresponding MeSH terms. In this paper, we present a new indexing approach that leverages term co-occurrence frequencies and latent term associations computed using MeSH term sets corresponding to a set of nearly 18 million articles already indexed with MeSH terms by indexers at NLM. The main goal of our study is to gauge the potential of output label co-occurrences, latent associations, and relationships extracted from free text in both unsupervised and supervised indexing approaches. In this paper, using a novel and purely unsupervised approach, we achieve a micro-F-score that is comparable to those obtained using supervised machine learning techniques. By incorporating term co-occurrence and latent association features into a supervised learning framework, we also improve over the best results published on two public datasets.

  9. Medical Image Processing for Fully Integrated Subject Specific Whole Brain Mesh Generation

    Directory of Open Access Journals (Sweden)

    Chih-Yang Hsu

    2015-05-01

    Full Text Available Currently, anatomically consistent segmentation of vascular trees acquired with magnetic resonance imaging requires the use of multiple image processing steps, which, in turn, depend on manual intervention. In effect, segmentation of vascular trees from medical images is time consuming and error prone due to the tortuous geometry and weak signal in small blood vessels. To overcome errors and accelerate the image processing time, we introduce an automatic image processing pipeline for constructing subject specific computational meshes for entire cerebral vasculature, including segmentation of ancillary structures; the grey and white matter, cerebrospinal fluid space, skull, and scalp. To demonstrate the validity of the new pipeline, we segmented the entire intracranial compartment with special attention of the angioarchitecture from magnetic resonance imaging acquired for two healthy volunteers. The raw images were processed through our pipeline for automatic segmentation and mesh generation. Due to partial volume effect and finite resolution, the computational meshes intersect with each other at respective interfaces. To eliminate anatomically inconsistent overlap, we utilized morphological operations to separate the structures with a physiologically sound gap spaces. The resulting meshes exhibit anatomically correct spatial extent and relative positions without intersections. For validation, we computed critical biometrics of the angioarchitecture, the cortical surfaces, ventricular system, and cerebrospinal fluid (CSF spaces and compared against literature values. Volumina and surface areas of the computational mesh were found to be in physiological ranges. In conclusion, we present an automatic image processing pipeline to automate the segmentation of the main intracranial compartments including a subject-specific vascular trees. These computational meshes can be used in 3D immersive visualization for diagnosis, surgery planning with haptics

  10. Large-scale subject-specific cerebral arterial tree modeling using automated parametric mesh generation for blood flow simulation.

    Science.gov (United States)

    Ghaffari, Mahsa; Tangen, Kevin; Alaraj, Ali; Du, Xinjian; Charbel, Fady T; Linninger, Andreas A

    2017-12-01

    In this paper, we present a novel technique for automatic parametric mesh generation of subject-specific cerebral arterial trees. This technique generates high-quality and anatomically accurate computational meshes for fast blood flow simulations extending the scope of 3D vascular modeling to a large portion of cerebral arterial trees. For this purpose, a parametric meshing procedure was developed to automatically decompose the vascular skeleton, extract geometric features and generate hexahedral meshes using a body-fitted coordinate system that optimally follows the vascular network topology. To validate the anatomical accuracy of the reconstructed vasculature, we performed statistical analysis to quantify the alignment between parametric meshes and raw vascular images using receiver operating characteristic curve. Geometric accuracy evaluation showed an agreement with area under the curves value of 0.87 between the constructed mesh and raw MRA data sets. Parametric meshing yielded on-average, 36.6% and 21.7% orthogonal and equiangular skew quality improvement over the unstructured tetrahedral meshes. The parametric meshing and processing pipeline constitutes an automated technique to reconstruct and simulate blood flow throughout a large portion of the cerebral arterial tree down to the level of pial vessels. This study is the first step towards fast large-scale subject-specific hemodynamic analysis for clinical applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Quantitative biomedical annotation using medical subject heading over-representation profiles (MeSHOPs

    Directory of Open Access Journals (Sweden)

    Cheung Warren A

    2012-09-01

    Full Text Available Abstract Background MEDLINE®/PubMed® indexes over 20 million biomedical articles, providing curated annotation of its contents using a controlled vocabulary known as Medical Subject Headings (MeSH. The MeSH vocabulary, developed over 50+ years, provides a broad coverage of topics across biomedical research. Distilling the essential biomedical themes for a topic of interest from the relevant literature is important to both understand the importance of related concepts and discover new relationships. Results We introduce a novel method for determining enriched curator-assigned MeSH annotations in a set of papers associated to a topic, such as a gene, an author or a disease. We generate MeSH Over-representation Profiles (MeSHOPs to quantitatively summarize the annotations in a form convenient for further computational analysis and visualization. Based on a hypergeometric distribution of assigned terms, MeSHOPs statistically account for the prevalence of the associated biomedical annotation while highlighting unusually prevalent terms based on a specified background. MeSHOPs can be visualized using word clouds, providing a succinct quantitative graphical representation of the relative importance of terms. Using the publication dates of articles, MeSHOPs track changing patterns of annotation over time. Since MeSHOPs are quantitative vectors, MeSHOPs can be compared using standard techniques such as hierarchical clustering. The reliability of MeSHOP annotations is assessed based on the capacity to re-derive the subset of the Gene Ontology annotations with equivalent MeSH terms. Conclusions MeSHOPs allows quantitative measurement of the degree of association between any entity and the annotated medical concepts, based directly on relevant primary literature. Comparison of MeSHOPs allows entities to be related based on shared medical themes in their literature. A web interface is provided for generating and visualizing MeSHOPs.

  12. Quantitative biomedical annotation using medical subject heading over-representation profiles (MeSHOPs).

    Science.gov (United States)

    Cheung, Warren A; Ouellette, B F Francis; Wasserman, Wyeth W

    2012-09-27

    MEDLINE®/PubMed® indexes over 20 million biomedical articles, providing curated annotation of its contents using a controlled vocabulary known as Medical Subject Headings (MeSH). The MeSH vocabulary, developed over 50+ years, provides a broad coverage of topics across biomedical research. Distilling the essential biomedical themes for a topic of interest from the relevant literature is important to both understand the importance of related concepts and discover new relationships. We introduce a novel method for determining enriched curator-assigned MeSH annotations in a set of papers associated to a topic, such as a gene, an author or a disease. We generate MeSH Over-representation Profiles (MeSHOPs) to quantitatively summarize the annotations in a form convenient for further computational analysis and visualization. Based on a hypergeometric distribution of assigned terms, MeSHOPs statistically account for the prevalence of the associated biomedical annotation while highlighting unusually prevalent terms based on a specified background. MeSHOPs can be visualized using word clouds, providing a succinct quantitative graphical representation of the relative importance of terms. Using the publication dates of articles, MeSHOPs track changing patterns of annotation over time. Since MeSHOPs are quantitative vectors, MeSHOPs can be compared using standard techniques such as hierarchical clustering. The reliability of MeSHOP annotations is assessed based on the capacity to re-derive the subset of the Gene Ontology annotations with equivalent MeSH terms. MeSHOPs allows quantitative measurement of the degree of association between any entity and the annotated medical concepts, based directly on relevant primary literature. Comparison of MeSHOPs allows entities to be related based on shared medical themes in their literature. A web interface is provided for generating and visualizing MeSHOPs.

  13. METHODICAL ENSURING ELECTRONIC SUBJECT ANALYSIS OF DOCUMENTS: FEATURES OF EDITING SUBJECT HEADINGS IN ABIS ABSOTHEQUE UNICODE

    Directory of Open Access Journals (Sweden)

    Т. М. Бикова

    2016-03-01

    Full Text Available The purpose of our article is consideration of questions of electronic subject analysis of documents and methodical ensuring editing subject headings in the electronic catalog. The main objective of our article – to show a technique of editing the dictionary of subject headings, to study and apply this technique in work of libraries of higher education institutions. Object of research is the thesaurus of subject headings of the electronic catalog of the Scientific Library of Odessa I. I. Mechnikov National University. To improve the efficiency and quality of the search capabilities of the electronic catalog needs constant work on its optimization, that is, technical editing of subject headings, the opening of new subject headings and subheadings.  In Scientific library the instruction, which regulates a technique of edition of subject headings, was developed and put into practice and establishes rationing of this process. The main finding of the work should be to improve the level of bibliographic service users and rationalization systematizer. The research findings have the practical value for employees of libraries.

  14. User's guide to Sears List of subject headings

    CERN Document Server

    Satija, Mohinder P

    2008-01-01

    This book is a companion to the 19th edition of the Sears List and a complete course in the theory and practice of the List for practitioners, teachers, and learners. The object of this small, practical introduction is to be simple, clear, and illustrative, assuming the reader has little prior knowledge either of the Sears List or of subject headings work in general.

  15. Revision of the Wayne State University Medical Library subject catalog using the 1966 Medical Subject Heading system.

    Science.gov (United States)

    Pings, V M; Ferrario, J A

    1967-01-01

    Wayne State University Medical Library (WSUML) revised its monograph subject catalog in 1961 utilizing the 1960 edition of MeSH as an authority list. With the introduction of MEDLARS in 1963 by NLM, all topical subheadings were omitted from MeSH. Inasmuch as this omission could not accommodate the needs of WSUML, the 1960 edition of MeSH was retained as a guideline. In January 1966, when MeSH resumed the incorporation of topical subheadings, WSUML was faced with a decision whether to continue the current policy or to adopt the form as presented in the latest edition of MeSH. This report describes the methodology employed in adopting a new policy, the findings which resulted from the change, and an evaluation of this reorganization.

  16. Subject Headings for Church or Synagogue Libraries. 2nd Revised Edition. CSLA Guide No. 8.

    Science.gov (United States)

    Kersten, Dorothy B.

    This guide to subject headings for church or synagogue libraries begins by providing guidelines for the subject cataloging process. These guidelines are presented under seven headings: (1) Selecting the Subject Heading (by names of persons, religious congregations and orders, sects and denominations, places, holidays, and new subjects); (2)…

  17. Objective and subjective outcome 3 years after synthetic transobturator nonabsorbable anterior mesh use in symptomatic advanced pelvic organ prolapse surgery

    Directory of Open Access Journals (Sweden)

    Tsia-Shu Lo

    2015-05-01

    Conclusion: The Perigee System gave a favorable result in both anatomical and subjective success rates with a low rate of mesh-related morbidities. The strength of the study reported here is its long-term follow up of a relatively large number of patients and the use of validated questionnaires. Limitations are that it is not a RCT; hence, selection and indication bias is unavoidable. The favorable outcome and low morbidities resulting from mesh use is from a single surgeon's perspective and may not be generalized to others.

  18. CINAHL list of subject headings: a nursing thesaurus revised.

    Science.gov (United States)

    Fishel, C C; Graham, K E; Greer, D M; Gupta, A D; Lockwood, D K; Prime, E E

    1985-04-01

    The rationale and methods for revising the thesaurus of one of the major health sciences indexing tools are discussed. Computer production of the Cumulative Index to Nursing & Allied Health Literature and the possibility of online access mandated a revision of the list of subject headings. CINAHL has maintained a policy of responding to user needs and to changes in the nursing and allied health literature, and user input was encouraged during revision of the thesaurus. The methods of structural revision are described, and major changes in the thesaurus are detailed. Modification of the thesaurus is expected to have a far-reaching impact on the retrieval of information in nursing and allied health. Nursing and Allied Health (CINAHL) is now available online through DIALOG (file 218) and BRS (access code NAHL).

  19. Comparison of Medical Subject Headings and text-word searches in MEDLINE to retrieve studies on sleep in healthy individuals*

    Science.gov (United States)

    Jenuwine, Elizabeth S.; Floyd, Judith A.

    2004-01-01

    Objective: The objective was to investigate the performance of two search strategies in the retrieval of primary research papers containing descriptive information on the sleep of healthy people from MEDLINE. Methodology: Two search strategies—one based on the use of only Medical Subject Headings (MeSH), the second based on text-word searching—were evaluated as to their specificity and sensitivity in retrieving a set of relevant research papers published in the journal Sleep from 1996 to 2001 that were preselected by a hand search. Results: The subject search provided higher specificity than the text-word search (66% and 47%, respectively) but lower sensitivity (78% for the subject search versus 88% for the text-word search). Each search strategy gave some unique relevant hits. Conclusions: The two search strategies complemented each other and should be used together for maximal retrieval. No combination of MeSH terms could provide comprehensive yet reasonably precise retrieval of relevant articles. The text-word searching had sensitivity and specificity comparable to the subject search. In addition, use of text words “normal,” “healthy,” and “control” in the title or abstract fields to limit the final sets provided an efficient way to increase the specificity of both search strategies. PMID:15243641

  20. Gastrointestinal Physiology During Head Down Tilt Bedrest in Human Subjects

    Science.gov (United States)

    Vaksman, Z.; Guthienz, J.; Putcha, L.

    2008-01-01

    Introduction: Gastrointestinal (GI) motility plays a key role in the physiology and function of the GI tract. It directly affects absorption of medications and nutrients taken by mouth, in addition to indirectly altering GI physiology by way of changes in the microfloral composition and biochemistry of the GI tract. Astronauts have reported nausea, loss of appetite and constipation during space flight all of which indicate a reduction in GI motility and function similar to the one seen in chronic bed rest patients. The purpose of this study is to determine GI motility and bacterial proliferation during -6 degree head down tilt bed rest (HTD). Methods: Healthy male and female subjects between the ages of 25-40 participated in a 60 day HTD study protocol. GI transit time (GITT) was determined using lactulose breath hydrogen test and bacterial overgrowth was measured using glucose breath hydrogen test. H. Pylori colonization was determined using C13-urea breath test (UBIT#). All three tests were conducted on 9 days before HDT, and repeated on HDT days 2, 28, 58, and again on day 7 after HDT. Results: GITT increased during HTD compared to the respective ambulatory control values; GITT was significantly lower on day 7 after HTD. A concomitant increase in bacterial colonization was also noticed during HDT starting after approximately 28 days of HDT. However, H. Pylori proliferation was not recorded during HDT as indicated by UBIT#. Conclusion: GITT significantly decreased during HDT with a concomitant increase in the proliferation of GI bacterial flora but not H. pylori.

  1. Medical subject heading (MeSH) annotations illuminate maize genetics and evolution

    Science.gov (United States)

    In the modern era, high-density marker panels and/or whole-genome sequencing,coupled with advanced phenotyping pipelines and sophisticated statistical methods, have dramatically increased our ability to generate lists of candidate genes or regions that are putatively associated with phenotypes or pr...

  2. SPARED RECOGNITION CAPACITY IN ELDERLY AND CLOSED-HEAD-INJURY SUBJECTS WITH CLINICAL MEMORY DEFICITS

    NARCIS (Netherlands)

    Spikman, J.M.; Berg, I.J.; Deelman, B.G.

    This study describes the performance of three groups of subjects on a pictorial forced-recognition task, the Hundred Pictures Test. The aim was to determine whether subjects with memory deficits (elderly and closed-head-injured subjects) would perform as well as healthy young subjects, both on

  3. Survey of keyword adjustment of published articles medical subject headings in journal of mazandaran university of medical sciences (2009-2010).

    Science.gov (United States)

    Kabirzadeh, Azar; Siamian, Hasan; Abadi, Ebrahim Bagherian Farah; Saravi, Benyamin Mohseni

    2013-01-01

    NONE DECLARED. Keywords are the most important tools for Information retrieval. They are usually used for retrieval of articles based on contents of information reserved from printed and electronic resources. Retrieval of appropriate keywords from Medical Subject Headings (MeSH) can impact with exact, correctness and short time on information retrieval. Regarding the above mentioned matters, this study was done to compare the Latin keywords was in the articles published in the Journal of Mazandaran University of Medical Sciences. This is a descriptive study. The data were extracted from the key words of Englsih abstracts of articles published in the years 2009-2010 in the Journal of Mazandaran University of Medical Sciences by census method. Checklist of data collection is designed, based on research objectives and literature review which has face validity. Compliance rate in this study was to determine if the keywords cited in this article as a full subject of the main subject headings in a MeSH (Bold and the selected word) is a perfect adjustment. If keywords were cited in the article but the main heading is not discussed in the following main topics to be discussed with reference to See and See related it has considered has partial adjustment. Out of 148 articles published in 12 issues in proposed time of studying, 72 research papers were analyzed. The average numbers of authors in each article were 4 ± 1. Results showed that most of specialty papers 42 (58. 4%), belonging to the (Department of Clinical Sciences) School of Medicine, 11 (15.3%) Basic Science, 6(8.4%) Pharmacy, Nursing and Midwifery 5(6.9%), 4(5.5%) Health, paramedical Sciences 3(4.2%), and non medical article 1(1.3%) school of medicine. In general, results showed that 80 (30%) of key words have been used to complete the adjustment. Also, only 1(1.4%) had complete adjustment with all the MeSH key words and in 8 articles(11.4%) key words of had no adjustment with MeSH. The results showed that only

  4. Correlation between Trunk Posture and Neck Reposition Sense among Subjects with Forward Head Neck Postures

    OpenAIRE

    Han Suk Lee; Hyung Kuk Chung; Sun Wook Park

    2015-01-01

    Objective. To assess the correlation of abnormal trunk postures and reposition sense of subjects with forward head neck posture (FHP). Methods. In all, postures of 41 subjects were evaluated and the FHP and trunk posture including shoulder, scapular level, pelvic side, and anterior tilting degrees were analyzed. We used the head repositioning accuracy (HRA) test to evaluate neck position senses of neck flexion, neck extension, neck right and left side flexion, and neck right and left rotation...

  5. Activation of rectus capitis posterior major muscles during voluntary retraction of the head in asymptomatic subjects.

    Science.gov (United States)

    Hallgren, Richard C; Rowan, Jacob J; Bai, Peng; Pierce, Steven J; Shafer-Crane, Gail A; Prokop, Lawrence L

    2014-01-01

    The purpose of this study was to assess levels of electromyographic activity measured from rectus capitis posterior major (RCPM) muscles of asymptomatic subjects as their heads moved from a self-defined neutral position to a retracted position. A 2 × 2 within-subjects factorial research design was used. Disposable, intramuscular electrodes were used to collect electromyographic data from asymptomatic subjects between the ages of 20 and 40 years old. Data analysis was performed using mixed effects β regression models. Activation of RCPM muscles was found to significantly increase (P < .0001) as the head moved from a self-defined neutral position to a retracted position. Rectus capitis posterior major muscle activation levels, measured as a function of head position, have not been previously reported. The findings from this study showed that RCPM muscle activation significantly increases during voluntary retraction of the head. Copyright © 2014 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  6. Effect of Head Elevation on Passive Upper Airway Collapsibility in Normal Subjects under Propofol Anesthesia

    Science.gov (United States)

    Kobayashi, Masato; Ayuse, Takao; Hoshino, Yuko; Kurata, Shinji; Moromugi, Shunji; Schneider, Hartmut; Kirkness, Jason P.; Schwartz, Alan R.; Oi, Kumiko

    2011-01-01

    Background Head elevation can restore airway patency during anesthesia, although its effect may be offset by concomitant bite opening or accidental neck flexion. The aim of this study is to examine the effect of head elevation on the passive upper airway collapsibility during propofol anesthesia. Method Twenty male subjects were studied, randomized to one of two experimental groups: Fixed-jaw or Free-jaw. Propofol infusion was used for induction and to maintain blood concentration constant at a target level between 1.5 and 2.0 μg/ml. Nasal mask pressure (PN) was intermittently reduced to evaluate the upper airway collapsibility (passive PCRIT) and upstream resistance (RUS) at each level of head elevation (0, 3, 6, & 9 cm). We measured the Frankfort plane (head flexion) and the mandible plane (jaw opening) angles at each level of head elevation. Analysis of variance was used to determine effect of head elevation on PCRIT, head flexion and jaw opening within each group. Results In both groups the Frankfort plane and mandible plane angles increased as with head elevation (P elevation decreased upper airway collapsibility (PCRIT ~ −7 cmH2O at greater than 6 cm elevation) compared to the baseline position (PCRIT ~ −3 cmH2O at 0 cm elevation; P elevating the head position by 6 cm while ensuring mouth closure (centric occlusion) produces substantial decreases in upper airway collapsibility and maintains upper airway patency during anesthesia. PMID:21701378

  7. Effect of head elevation on passive upper airway collapsibility in normal subjects during propofol anesthesia.

    Science.gov (United States)

    Kobayashi, Masato; Ayuse, Takao; Hoshino, Yuko; Kurata, Shinji; Moromugi, Shunji; Schneider, Hartmut; Kirkness, Jason P; Schwartz, Alan R; Oi, Kumiko

    2011-08-01

    Head elevation can restore airway patency during anesthesia, although its effect may be offset by concomitant bite opening or accidental neck flexion. The aim of this study is to examine the effect of head elevation on the passive upper airway collapsibility during propofol anesthesia. Twenty male subjects were studied, randomized to one of two experimental groups: fixed-jaw or free-jaw. Propofol infusion was used for induction and to maintain blood at a constant target concentration between 1.5 and 2.0 μg/ml. Nasal mask pressure (PN) was intermittently reduced to evaluate the upper airway collapsibility (passive PCRIT) and upstream resistance (RUS) at each level of head elevation (0, 3, 6, and 9 cm). The authors measured the Frankfort plane (head flexion) and the mandible plane (jaw opening) angles at each level of head elevation. Analysis of variance was used to determine the effect of head elevation on PCRIT, head flexion, and jaw opening within each group. In both groups the Frankfort plane and mandible plane angles increased with head elevation (P elevation decreased upper airway collapsibility (PCRIT ~ -7 cm H₂O at greater than 6 cm elevation) compared with the baseline position (PCRIT ~ -3 cm H₂O at 0 cm elevation; P Elevating the head position by 6 cm while ensuring mouth closure (centric occlusion) produces substantial decreases in upper airway collapsibility and maintains upper airway patency during anesthesia.

  8. Comparative Study between the "Lista de Encabezamientos de Materia" by Gloria Escamilla and the "Library of Congress Subject Heading" List.

    Science.gov (United States)

    Alvarez, Fernando

    This study shows to what extent Gloria Escamilla's "Lista de Encabezamientos de Materia," the only published Mexican subject heading list, is equivalent to the Library of Congress subject headings (LCSH). A LCSH heading sample is obtained from OCLC's Online Union Catalog. Using the EPIC search from OCLC, 1947 bibliographic records were…

  9. French MeSH Browser: a cross-language tool to access MEDLINE/PubMed.

    Science.gov (United States)

    Thirion, Benoit; Pereira, Susanne; Névéol, Aurélie; Dahamna, Badisse; Darmoni, Stéfan

    2007-10-11

    When searching the medical literature, health professionals and lay people strongly prefer to use their native language. Therefore, Medical Subject Headings (MeSH) translations would be helpful to those who are not fluent in English to access scientific papers indexed in the MEDLINE bibliographic database. Furthermore, medical terminologies such as MeSH are challenging in any language. In this context, a French MeSH Browser was developed.

  10. Cumulating the Supplements to the Seventh Edition of LC Subject Headings

    Directory of Open Access Journals (Sweden)

    Roy B. Torkington

    1973-12-01

    Full Text Available A description is presented of the project of the University of California Library Automation Program to cumulate the 1966 through 1971 supplements to the Library of Congress Subject Headings. The University of California Institute of Library Research MARC processing software, BIBCON, was used, with specially written programs. The resulting cumulation was edited, printed in book form, and made available to libraries. The final task involved merging six MARC files into one file of over 125,000 records and then printing that file in a format similar to that of LC Subject Headings. The project was a cooperative effort with participation by people from several UC campuses.

  11. PHYSIOLOGICAL ASSESSMENT OF HEAD-OUT AQUATIC EXERCISES IN HEALTHY SUBJECTS: A QUALITATIVE REVIEW

    Directory of Open Access Journals (Sweden)

    Tiago M Barbosa

    2009-06-01

    Full Text Available In the last decades head-out aquatic exercises became one of the most important physical activities within the health system. Massive research has been produced throughout these decades in order to better understand the role of head-out aquatic exercises in populations' health. Such studies aimed to obtain comprehensive knowledge about the acute and chronic response of subjects performing head-out aquatic exercises. For that, it is assumed that chronic adaptations represent the accumulation of acute responses during each aquatic session. The purpose of this study was to describe the "state of the art" about physiological assessment of head-out aquatic exercises based on acute and chronic adaptations in healthy subjects based on a qualitative review. The main findings about acute response of head-out aquatic exercise according to water temperature, water depth, type of exercise, additional equipment used, body segments exercising and music cadence will be described. In what concerns chronic adaptations, the main results related to cardiovascular and metabolic adaptations, muscular strength, flexibility and body composition improvements will be reported

  12. Analysing the Role of the Subject Head of Department in Secondary Schools in England and Wales: Towards a Theoretical Framework.

    Science.gov (United States)

    Turner, Chris; Bolam, Ray

    1998-01-01

    Argues that contingency theory offers a useful basis for considering the work of subject heads of department in (British) secondary schools, particularly if heads are actively trying to influence the quality of teaching and learning in their curriculum areas. Develops a provisional model to shed light on how department heads actually work with…

  13. Meshable: searching PubMed abstracts by utilizing MeSH and MeSH-derived topical terms

    OpenAIRE

    Kim, Sun; Yeganova, Lana; Wilbur, W. John

    2016-01-01

    Summary: Medical Subject Headings (MeSH?) is a controlled vocabulary for indexing and searching biomedical literature. MeSH terms and subheadings are organized in a hierarchical structure and are used to indicate the topics of an article. Biologists can use either MeSH terms as queries or the MeSH interface provided in PubMed? for searching PubMed abstracts. However, these are rarely used, and there is no convenient way to link standardized MeSH terms to user queries. Here, we introduce a web...

  14. Neck kinematics and sternocleidomastoid muscle activation during neck rotation in subjects with forward head posture

    Science.gov (United States)

    Kim, Man-Sig

    2015-01-01

    [Purpose] The present study investigated differences in the kinematics of the neck and activation of the sternocleidomastoid (SCM) muscle during neck rotation between subjects with and without forward head posture (FHP). [Subjects and Methods] Twenty-eight subjects participated in the study (14 with FHP, 14 without FHP). Subjects performed neck rotation in two directions, left and right. The kinematics of rotation-lateral flexion movement patterns were recorded using motion analysis. Activity in the bilateral SCM muscles was measured using surface electromyography. Differences in neck kinematics and activation of SCM between the groups were analyzed by independent t-tests. [Results] Maintaining FHP increased the rotation-lateral flexion ratio significantly in both directions. The FHP group had significantly faster onset time for lateral flexion movement in both directions during neck rotation. Regarding the electromyography of the SCM muscles during neck rotation in both directions, the activity values of subjects with FHP were greater than those of subjects without FHP for the contralateral SCM muscles. [Conclusion] FHP can induce changes in movement in the frontal plane and SCM muscle activation during neck rotation. Thus, clinicians should consider movement in the frontal plane as well as in the sagittal plane when assessing and treating patients with forward head posture. PMID:26696712

  15. Correlation between Trunk Posture and Neck Reposition Sense among Subjects with Forward Head Neck Postures

    Science.gov (United States)

    Lee, Han Suk; Chung, Hyung Kuk; Park, Sun Wook

    2015-01-01

    Objective. To assess the correlation of abnormal trunk postures and reposition sense of subjects with forward head neck posture (FHP). Methods. In all, postures of 41 subjects were evaluated and the FHP and trunk posture including shoulder, scapular level, pelvic side, and anterior tilting degrees were analyzed. We used the head repositioning accuracy (HRA) test to evaluate neck position senses of neck flexion, neck extension, neck right and left side flexion, and neck right and left rotation and calculated the root mean square error in trials for each subject. Spearman's rank correlation coefficients and regression analysis were used to assess the degree of correlation between the trunk posture and HRA value, and a significance level of α = 0.05 was considered. Results. There were significant correlations between the HRA value of right side neck flexion and pelvic side tilt angle (p postures. Conclusion. Verifying pelvic postures should be prioritized when movement is limited due to the vitiation of the proprioceptive sense of neck caused by FHP. PMID:26583125

  16. Correlation between Trunk Posture and Neck Reposition Sense among Subjects with Forward Head Neck Postures

    Directory of Open Access Journals (Sweden)

    Han Suk Lee

    2015-01-01

    Full Text Available Objective. To assess the correlation of abnormal trunk postures and reposition sense of subjects with forward head neck posture (FHP. Methods. In all, postures of 41 subjects were evaluated and the FHP and trunk posture including shoulder, scapular level, pelvic side, and anterior tilting degrees were analyzed. We used the head repositioning accuracy (HRA test to evaluate neck position senses of neck flexion, neck extension, neck right and left side flexion, and neck right and left rotation and calculated the root mean square error in trials for each subject. Spearman’s rank correlation coefficients and regression analysis were used to assess the degree of correlation between the trunk posture and HRA value, and a significance level of α = 0.05 was considered. Results. There were significant correlations between the HRA value of right side neck flexion and pelvic side tilt angle (p<0.05. If pelvic side tilting angle increases by 1 degree, right side neck flexion increased by 0.76 degrees (p=0.026. However, there were no significant correlations between other neck motions and trunk postures. Conclusion. Verifying pelvic postures should be prioritized when movement is limited due to the vitiation of the proprioceptive sense of neck caused by FHP.

  17. Trismus following different treatment modalities for head and neck cancer: a systematic review of subjective measures.

    Science.gov (United States)

    Loh, Sook Y; Mcleod, Robert W J; Elhassan, Hassan A

    2017-07-01

    The aim of this review was to compare systematically the subjective measure of trismus between different interventions to treat head and neck cancer, particularly those of the oropharynx. Using The Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) Guidelines, Six databases were searched for the text using various terms which include "oropharyngeal/head and neck cancer", "trismus/mouth opening" and the various treatment modalities. Included in the review were clinical studies (> or =10 patients). Three observers independently assessed the papers identified. Among the six studies reviewed, five showed a significantly worst outcome with regard to the quality-of-life questionnaire scores for a radiotherapy or surgery and radiotherapy (RT) ± chemotherapy or chemoradiotherapy when compared to surgery alone. Only one study showed no significant difference between surgery alone and other treatment modalities. Subjective quality-of-life measures are a concurrent part of modern surgical practice. Although subjective measures were utilised to measure post operative trismus successfully, there was no consensus as to which treatment modality had overall better outcomes, with conflicting studies in keeping with the current debate in this field. Larger and higher quality studies are needed to compare all three treatment modalities.

  18. Correlation between Trunk Posture and Neck Reposition Sense among Subjects with Forward Head Neck Postures.

    Science.gov (United States)

    Lee, Han Suk; Chung, Hyung Kuk; Park, Sun Wook

    2015-01-01

    To assess the correlation of abnormal trunk postures and reposition sense of subjects with forward head neck posture (FHP). In all, postures of 41 subjects were evaluated and the FHP and trunk posture including shoulder, scapular level, pelvic side, and anterior tilting degrees were analyzed. We used the head repositioning accuracy (HRA) test to evaluate neck position senses of neck flexion, neck extension, neck right and left side flexion, and neck right and left rotation and calculated the root mean square error in trials for each subject. Spearman's rank correlation coefficients and regression analysis were used to assess the degree of correlation between the trunk posture and HRA value, and a significance level of α = 0.05 was considered. There were significant correlations between the HRA value of right side neck flexion and pelvic side tilt angle (p neck flexion increased by 0.76 degrees (p = 0.026). However, there were no significant correlations between other neck motions and trunk postures. Verifying pelvic postures should be prioritized when movement is limited due to the vitiation of the proprioceptive sense of neck caused by FHP.

  19. Internal Lymphedema Correlates with Subjective and Objective Measures of Dysphagia in Head and Neck Cancer Patients.

    Science.gov (United States)

    Jackson, Leanne K; Ridner, Sheila H; Deng, Jie; Bartow, Carmin; Mannion, Kyle; Niermann, Ken; Gilbert, Jill; Dietrich, Mary S; Cmelak, Anthony J; Murphy, Barbara A

    2016-09-01

    Tumor/treatment-related internal lymphedema (IL) and/or external lymphedema (EL) are associated with functional deficits and increased symptom burden in head and neck cancer patients (HNCP). Previously, we noted association between EL/IL and patient-reported dysphagia using the Vanderbilt Head and Neck Symptom Survey (VHNSS) version 1.0. To determine the relationship between IL/EL and subjective and objective measures of swallowing function. Eighty-one HNCP completed: (1) VHNSS version 2.0, including 13 swallowing/nutrition-related questions grouped into three clusters: swallow solids (ss), swallow liquids (sl), and nutrition(nt); (2) physical assessment of EL using Foldi scale; (3) endoscopic assessment of IL using Patterson scale (n = 56); and (4) modified barium swallow study rated by dysphagia outcome and severity scale (DOSS) and in conjunction with a swallow evaluation by National Outcomes Measurement System (NOMS). Examinations were performed at varied time points to assess lymphedema spectrum, from baseline (n = 15, 18.1%) to 18 months post-therapy (n = 20, 24.1%). VHNSS swallow/nutrition items scores correlated with NOMS/DOSS ratings (p nutrition scores correlated with maximum grade of swelling for any single structure on Patterson scale: ss (0.43; p = 0.001); sl (0.38; p = 0.004); nt (0.41; p = 0.002). IL of aryepiglottic/pharyngoepiglottic folds, epiglottis, and pyriform sinus were most strongly correlated with VHNSS and NOMS ratings. NOMS/DOSS ratings correlated with EL (> = -0.34; p nutrition items and EL ( 0.20). IL correlated with subjective and objective measures of swallow dysfunction. Longitudinal analysis of trajectory and impact of IL/EL on dysphagia is ongoing.

  20. Monte Carlo study of the influence of energy spectra, mesh size, high Z element on dose and PVDR based on 1-D and 3-D heterogeneous mouse head phantom for Microbeam Radiation Therapy.

    Science.gov (United States)

    Lin, Hui; Jing, Jia; Xu, Liangfeng; Mao, Xiaoli

    2017-09-22

    To evaluate the influence of energy spectra, mesh sizes, high Z element on dose and PVDR in Microbeam Radiation Therapy (MRT) based on 1-D analogy-mouse-head-model (1-D MHM) and 3-D voxel-mouse-head-phantom (3-D VMHP) by Monte Carlo simulation. A Microbeam-Array-Source-Model was implemented into EGSnrc/DOSXYZnrc. The microbeam size is assumed to be 25μm, 50μm or 75μm in thickness and fixed 1mm in height with 200μmc-t-c. The influence of the energy spectra of ID17@ESRF and BMIT@CLS were investigated. The mesh size was optimized. PVDR in 1-D MHM and 3-D VMHP was compared with the homogeneous water phantom. The arc influence of 3-D VMHP filled with water (3-D VMHWP) was compared with the rectangle phantom. PVDR of the lower BMIT@CLS spectrum is 2.4times that of ID17@ESRF for lower valley dose. The optimized mesh is 5µm for 25µm, and 10µm for 50µm and 75µm microbeams with 200µmc-t-c. A 500μm skull layer could make PVDR difference up to 62.5% for 1-D MHM. However this influence is limited (influence is limited for the more depth (influence of 3-D heterogeneous media. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. MEDLINE MeSH Indexing: Lessons Learned from Machine Learning and Future Directions

    DEFF Research Database (Denmark)

    Jimeno-Yepes, Antonio; Mork, James G.; Wilkowski, Bartlomiej

    2012-01-01

    Map and a k-NN approach called PubMed Related Citations (PRC). Our motivation is to improve the quality of MTI based on machine learning. Typical machine learning approaches fit this indexing task into text categorization. In this work, we have studied some Medical Subject Headings (MeSH) recommended by MTI...... and analyzed the issues when using standard machine learning algorithms. We show that in some cases machine learning can improve the annotations already recommended by MTI, that machine learning based on low variance methods achieves better performance and that each MeSH heading presents a different behavior...

  2. Distancing, self-esteem, and subjective well-being in head and neck cancer.

    Science.gov (United States)

    Devins, Gerald M; Wong, Janice C; Payne, Ada Y M; Lebel, Sophie; Lee, Ruth N F; Mah, Kenneth; Irish, Jonathan; Rodin, Gary

    2015-11-01

    Distancing (i.e. construing oneself as dissimilar to a negatively-stereotyped group) preserves self-esteem and may benefit other domains of subjective well-being. Head and neck cancer (HNC) is stigmatized because major risk factors include avoidable lifestyle variables (smoking, alcohol consumption, and human papilloma virus). Because the benefits of coping efforts, such as distancing, are most evident when people are under stress, we hypothesize that the psychosocial benefits of distancing will be most pronounced when cancer and its treatment interfere substantially with participation in valued activities and interests (i.e. high illness intrusiveness). To test whether distancing preserves self-esteem and other domains of subjective well-being (SWB) in HNC, especially when illness intrusiveness is high. Five hundred and twenty-two HNC outpatients completed a semantic-differential measure of perceived similarity to the 'cancer patient' and measures of illness intrusiveness, self-esteem, depressive symptoms, and psychological well-being in structured interviews. Evaluations of the 'cancer patient' reflected cancer stereotypes. A statistically significant interaction supported the central hypothesis: When people held negative stereotypes, those who construed themselves as similar to the 'cancer patient' reported lower self-esteem than those who construed themselves as dissimilar. Distancing did not benefit other SWB variables. Some results were counter-intuitive: e.g. Emotional distress increased with increasing illness intrusiveness when people did not hold negative cancer stereotypes, but when they held highly negative stereotypes, distress decreased with increasing illness intrusiveness. Overall, distancing preserved self-esteem in people with HNC and was associated with benefits in other SWB domains. Copyright © 2015 John Wiley & Sons, Ltd.

  3. PubMed in progress: latest changes in MeSH and MyNCBI.

    Science.gov (United States)

    Giglia, E

    2011-09-01

    PubMed interface re-engineering has moved further steps with the latest changes in the MeSH - Medical Subject Headings database and in the MyNCBI homepage. Aim of this contribution is to present the most relevant added feature in order to improve your query efficiency.

  4. PubMed in progress: latest changes in MeSH and MyNCBI

    OpenAIRE

    Giglia, Elena

    2011-01-01

    PubMed interface re-engineering has moved further steps with the latest changes in the MeSH – Medical Subject Headings database and in the MyNCBI homepage. Aim of thi socntributon is to present the most relevant added feature in order to improve your query efficiency

  5. MeSH ORA framework: R/Bioconductor packages to support MeSH over-representation analysis.

    Science.gov (United States)

    Tsuyuzaki, Koki; Morota, Gota; Ishii, Manabu; Nakazato, Takeru; Miyazaki, Satoru; Nikaido, Itoshi

    2015-02-15

    In genome-wide studies, over-representation analysis (ORA) against a set of genes is an essential step for biological interpretation. Many gene annotation resources and software platforms for ORA have been proposed. Recently, Medical Subject Headings (MeSH) terms, which are annotations of PubMed documents, have been used for ORA. MeSH enables the extraction of broader meaning from the gene lists and is expected to become an exhaustive annotation resource for ORA. However, the existing MeSH ORA software platforms are still not sufficient for several reasons. In this work, we developed an original MeSH ORA framework composed of six types of R packages, including MeSH.db, MeSH.AOR.db, MeSH.PCR.db, the org.MeSH.XXX.db-type packages, MeSHDbi, and meshr. Using our framework, users can easily conduct MeSH ORA. By utilizing the enriched MeSH terms, related PubMed documents can be retrieved and saved on local machines within this framework.

  6. Orthopaedic literature and MeSH.

    Science.gov (United States)

    Nelson, Stuart J; Schulman, Jacque-Lynne

    2010-10-01

    Since 1916 there has been a recognized demand for a method of classification of orthopaedic literature inclusive enough to permit the proper collection and retrieval of all literature on the subject. Today, MEDLINE, available through the PubMed interface, has become the de facto standard for organization and retrieval of medical literature. The Medical Subject Headings (MeSH), used to provide indexing and assist in searching, are partly responsible for this standard. Understanding how MeSH is built and maintained may lead the user to a better understanding of how to use MEDLINE, and what to expect from the indexing of an article. The purpose of this review is to provide an understanding of the organization of large quantities of indexed material, the indexing process and the considerations involved in developing an indexing vocabulary. WHERE ARE WE NOW?: Successful terminology development and use, a prerequisite for any sharing of information by electronic means, depends on both user (how the user is expected to use the system) and information (how the information is organized) models. MEDLINE has a simple user model and a simpler information model. The user is expected to determine what is relevant and which MeSH descriptors are appropriate. WHERE DO WE NEED TO GO?: While MEDLINE through PubMed is a success as viewed by the number of hits, further improvements will depend on better, faster indexing with a controlled terminology. Terminology development requires careful consideration of the nature of the subject, how users employ the terminology, the overall purpose of the terminology, and the framework of the systems in which it is used. HOW DO WE GET THERE?: For the future, understanding terminology development might enable the user to comprehend some of the issues involved in sharing of other information by electronic means. Further improvements in the availability and accessibility of medical literature will depend on continued maintenance and development of MeSH

  7. THE SHORT-TERM EFFECT OF A HOME-BASED PROGRAM TO CORRECT FORWARD HEAD POSTURE IN ASYMPTOMATIC SUBJECTS

    Directory of Open Access Journals (Sweden)

    Ahmed Omar Abdelnaeem

    2015-08-01

    Full Text Available Background: Neck pain and dysfunction may be the consequence of adopting sustained non-neutral spinal postures. Such postures are associated with increased activation of the neck-shoulder stabilizer muscles, which eventually increase the loading of cervical spine. Forward head posture is a common postural dysfunction that has been associated with many musculoskeletal disorders. The purpose of the study was to investigate the effects of deep cervical flexor muscles training on the severity of forward head posture in asymptomatic subjects. Methods: Forty-one asymptomatic subjects volunteered in this study. Participants were randomly assigned into an intervention group (n= 20that received a home-based training of deep cervical flexor muscles for 6-weeks, and a control group(n= 21 that received only the assessment procedure. Subjects were assessed at baseline and 6weeks later with regards to the severity of forward head as indicated by the cranio-vertebral angle. Also, the strength and endurance of the deep flexor muscles were assessed. Results: After six weeks, participants in the intervention group showed significant improvement in all measured variables compared to the control group. Furthermore, participants in the intervention group showed significant difference in all measured variables after 6-weeks of training compared to baseline, whereas those in the control group remained the same. Conclusion: Six-weeks of deep cervical training improves forward head posture and deep flexors strength and endurance in asymptomatic subjects. Thus, this exercise could be used as a preventive measure against the development of neck dysfunction in at risk population even before the onset of any symptoms.

  8. Hyoid bone position and head posture comparison in skeletal Class I and Class II subjects: A retrospective cephalometric study

    Directory of Open Access Journals (Sweden)

    Pawankumar Dnyandeo Tekale

    2014-01-01

    Full Text Available Objective: The aim of the study was to investigate the hyoid bone position and the head posture using lateral cephalograms in subjects with skeletal Class I and skeletal Class II pattern and to investigate the gender differences. Materials and Methods: The study used lateral cephalograms of 40 subjects (20 skeletal Class I pattern; 20 skeletal Class II pattern. Lateral cephalograms were traced and analyzed for evaluation of the hyoid bone position and the head posture using 34 parameters. Independent sample t-test was performed to compare the differences between the two groups and between genders in each group. Statistical tests were performed using NCSS 2007 software (NCSST, Kaysville, Utah, USA. Results: The linear measurements between the hyoid bone (H and cervical spine (CV2ia, the nasion-sella line, palatal line nasion line, the anterior nasal spine (ANS to perpendicular projection of H on the NLP (NLP- Nasal Linear Projection (H-NLP/ANS as well as the posterior cranial points (Bo, Ar and S points were found to be less in skeletal Class II subjects. The measurement H-CV2ia was found to be less in males with skeletal Class I pattern and H-CV4ia was found to be less in males with skeletal Class II pattern. The natural head posture showed no significant gender differences. Conclusion: The position of hyoid bone was closer to the cervical vertebra horizontally in skeletal Class II subjects when compared with skeletal Class I subjects. In males, the hyoid bone position was closer to the cervical vertebra horizontally both in skeletal Class I and skeletal Class II subjects.

  9. Meshable: searching PubMed abstracts by utilizing MeSH and MeSH-derived topical terms.

    Science.gov (United States)

    Kim, Sun; Yeganova, Lana; Wilbur, W John

    2016-10-01

    Medical Subject Headings (MeSH(®)) is a controlled vocabulary for indexing and searching biomedical literature. MeSH terms and subheadings are organized in a hierarchical structure and are used to indicate the topics of an article. Biologists can use either MeSH terms as queries or the MeSH interface provided in PubMed(®) for searching PubMed abstracts. However, these are rarely used, and there is no convenient way to link standardized MeSH terms to user queries. Here, we introduce a web interface which allows users to enter queries to find MeSH terms closely related to the queries. Our method relies on co-occurrence of text words and MeSH terms to find keywords that are related to each MeSH term. A query is then matched with the keywords for MeSH terms, and candidate MeSH terms are ranked based on their relatedness to the query. The experimental results show that our method achieves the best performance among several term extraction approaches in terms of topic coherence. Moreover, the interface can be effectively used to find full names of abbreviations and to disambiguate user queries. https://www.ncbi.nlm.nih.gov/IRET/MESHABLE/ CONTACT: sun.kim@nih.gov Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.

  10. [Predict factors associated with malnutrition from patient generated subjective global assessment (PG-SGA) in head and neck cancer patients].

    Science.gov (United States)

    Arribas, L; Hurtós, L; Milà, R; Fort, E; Peiró, I

    2013-01-01

    Patient Generated Subjective Global Assessment (PG-SGA) is a validated tool for nutrition evaluation in patients with cancer. The aim of our study was to estimate the prevalence of malnutrition in head and neck cancer patients at diagnosis and evaluate the independent prognostic factors for malnutrition from PG-SGA. All outpatients attending at the Head and Neck Cancer Multidisciplinary Meeting for primary diagnosis, staging and treatment were evaluated by an oncology dietitian using the patient generated subjective global assessment (PG-SGA). Patients with recurrences or secondary tumours will be excluded. 64 patients were evaluated (55 men and 9 women) with an average age of 63 years and body mass index (BMI) of 25.3 kg/m(2) (SD ± 5.18). After the nutritional assessment we observed that 43.8% of patients were malnourished or at risk of malnutrition. The most frequent symptom at diagnosis was dysphagia (48.4%) and anorexia (26.6%). From PG-SGA, the main prognostic factors (p<0,001) were the percentage of weight loss, serum albumin levels, BMI and the presence of dysphagia or/and anorexia prior diagnosis. Parameters as BMI, weight loss and low albumin levels at the time of diagnosis in head and neck cancer patients are independent predictors for malnutrition as well as the presence of anorexia or dysphagia.reaffirms the need for sustainability of interventions over time. Copyright © AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.

  11. The multi-modal responses of a physical head model subjected to various blast exposure conditions

    Science.gov (United States)

    Ouellet, S.; Phillippens, M.

    2017-11-01

    The local and global biomechanical response of the body to a blast wave is the first step of a sequence that leads to the development of stresses and strains which can exceed the tolerance of brain tissue. These stresses and strains may then lead to neuro-physical changes in the brain and contribute to initiate a cascade of events leading to injury. The specific biomechanical pathways by which the blast energy is transmitted through the head structure are, however, not clearly understood. Multiple transmission mechanisms have been proposed to explain the generation of brain stresses following the impingement of a blast wave on the head. With the use of a physical head model, the work presented here aims at demonstrating that the proposed transmission mechanisms are not mutually exclusive. They are part of a continuum of head responses where, depending on the exposure conditions, a given mechanism may or may not dominate. This article presents the joint analysis of previous blast test results generated with the brain injury protection evaluation device (BIPED) headform under four significantly different exposure conditions. The focus of the analysis is to demonstrate how the nature of the recorded response is highly dependent on the exposure characteristics and consequently, on the method used to reproduce blast exposure in a laboratory environment. The timing and magnitude of the variations in intra-cranial pressures (ICP) were analysed relative to the external pressure field in order to better understand the wave dynamics occurring within the brain structure of the headform. ICP waveforms were also analysed in terms of their energy spectral density to better identify the energy partitioning between the different modes of response. It is shown that the BIPED response is multi-modal and that the energy partitioning between its different modes of response is greatly influenced by exposure characteristics such as external peak overpressure, impulse, blast wave

  12. Dental needs in Brazilian patients subjected to head and neck radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Ana Carolina de Mesquita Netto; Jorge, Jacks; Almeida, Oslei Paes de; Lopes, Marcio Ajudarte [University of Campinas (UNICAMP), Piracicaba, SP (Brazil). Piracicaba Dental School. Dept. of Oral Diagnosis], e-mail: malopes@fop.unicamp.br; Esteves, Sergio Carlos Barros [Center of Oncology, Piracicaba, SP (Brazil)

    2009-07-01

    In spite of its recognized benefits in the treatment of malignant tumors, radiation therapy have several side effects in the head and neck region. The evaluation of oral conditions by a dentist is important to prevent or minimize these problems. The aim of this retrospective review was to analyze the dental needs in 357 patients who received radiotherapy in the head and neck region and were treated at Orocentro/FOP/UNICAMP, between January 1990 and December 2004. Review of patient files showed that dental examination before radiotherapy was not performed in 148 patients (41.5%) and was done in 209 patients (58.5%). From the total of examined patients, 94 (45%) did not require dental procedures at the moment of examination, while 115 (55%) presented some sort of dental need. Following the patients after the radiotherapy, it was observed that the group of patients that was evaluated before radiation presented less need of restorations, root canal filling and dental extractions than those who were not evaluated. The results of this study confirm that the evaluation of oral conditions prior to radiotherapy is essential to minimize the dental needs, emphasizing the importance of the dentist in the multidisciplinary team that treats cancer patients. (author)

  13. Spherical geodesic mesh generation

    Energy Technology Data Exchange (ETDEWEB)

    Fung, Jimmy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kenamond, Mark Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Burton, Donald E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Shashkov, Mikhail Jurievich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-02-27

    In ALE simulations with moving meshes, mesh topology has a direct influence on feature representation and code robustness. In three-dimensional simulations, modeling spherical volumes and features is particularly challenging for a hydrodynamics code. Calculations on traditional spherical meshes (such as spin meshes) often lead to errors and symmetry breaking. Although the underlying differencing scheme may be modified to rectify this, the differencing scheme may not be accessible. This work documents the use of spherical geodesic meshes to mitigate solution-mesh coupling. These meshes are generated notionally by connecting geodesic surface meshes to produce triangular-prismatic volume meshes. This mesh topology is fundamentally different from traditional mesh topologies and displays superior qualities such as topological symmetry. This work describes the geodesic mesh topology as well as motivating demonstrations with the FLAG hydrocode.

  14. The Availability of MeSH in Vendor-Supplied Cataloguing Records, as Seen Through the Catalogue of a Canadian Academic Health Library

    Directory of Open Access Journals (Sweden)

    Pamela S. Morgan

    2007-09-01

    Full Text Available This study examines the prevalence of medical subject headings in vendor-supplied cataloguing records for publications contained within aggregated databases or publisher collections. In the first phase, the catalogue of one Canadian academic medical library was examined to determine the extent to which medical subject headings (MeSH are available in the vendor-supplied records. In the second phase, these results were compared to the catalogues of other Canadian academic medical libraries in order to reach a generalization regarding the availability of MeSH headings for electronic resources. MeSH was more widespread in records for electronic journals but was noticeably lacking in records for electronic monographs, and for Canadian publications. There is no standard for ensuring MeSH are assigned to monograph records for health titles and there is no library in Canada with responsibility for ensuring that Canadian health publications receive Medical Subject Headings. It is incumbent upon libraries using MeSH to ensure that vendors are aware of this need when purchasing record sets.

  15. Impact of head models in N170 component source imaging: results in control subjects and ADHD patients

    Science.gov (United States)

    Beltrachini, L.; Blenkmann, A.; von Ellenrieder, N.; Petroni, A.; Urquina, H.; Manes, F.; Ibáñez, A.; Muravchik, C. H.

    2011-12-01

    The major goal of evoked related potential studies arise in source localization techniques to identify the loci of neural activity that give rise to a particular voltage distribution measured on the surface of the scalp. In this paper we evaluate the effect of the head model adopted in order to estimate the N170 component source in attention deficit hyperactivity disorder (ADHD) patients and control subjects, considering faces and words stimuli. The standardized low resolution brain electromagnetic tomography algorithm (sLORETA) is used to compare between the three shell spherical head model and a fully realistic model based on the ICBM-152 atlas. We compare their variance on source estimation and analyze the impact on the N170 source localization. Results show that the often used three shell spherical model may lead to erroneous solutions, specially on ADHD patients, so its use is not recommended. Our results also suggest that N170 sources are mainly located in the right occipital fusiform gyrus for faces stimuli and in the left occipital fusiform gyrus for words stimuli, for both control subjects and ADHD patients. We also found a notable decrease on the N170 estimated source amplitude on ADHD patients, resulting in a plausible marker of the disease.

  16. Image quality analysis of high-density diffuse optical tomography incorporating a subject-specific head model

    Directory of Open Access Journals (Sweden)

    Yuxuan eZhan

    2012-05-01

    Full Text Available High-density diffuse optical tomography (HD-DOT methods have shown significant improvement in localization accuracy and image resolution compared to traditional topographic near infrared spectroscopy (NIRS of the human brain. In this work we provide a comprehensive evaluation of image quality in visual cortex mapping via a simulation study with the use of an anatomical head model derived from MRI data of a human subject. A model of individual head anatomy provides the surface shape and internal structure that allow for the construction of a more realistic physical model for the forward problem, as well as the use of a structural constraint in the inverse problem. The HD-DOT model utilized here incorporates multiple source-detector separations with continuous-wave data with added noise based on experimental results. To evaluate image quality we quantify the localization error and localized volume at half maximum (LVHM throughout a region of interest (ROI within the visual cortex and systematically analyze the use of whole brain tissue spatial constraint within image reconstruction. Our results demonstrate that an image quality with less than 10 mm in localization error and 1000 m3 in LVHM can be obtained up to 13 mm below the scalp surface with a typical unconstrained reconstruction and up to 18 mm deep when a spatial constraint based on the brain tissue is utilized.

  17. Comparison and combination of several MeSH indexing approaches.

    Science.gov (United States)

    Yepes, Antonio Jose Jimeno; Mork, James G; Demner-Fushman, Dina; Aronson, Alan R

    2013-01-01

    MeSH indexing of MEDLINE is becoming a more difficult task for the group of highly qualified indexing staff at the US National Library of Medicine, due to the large yearly growth of MEDLINE and the increasing size of MeSH. Since 2002, this task has been assisted by the Medical Text Indexer or MTI program. We extend previous machine learning analysis by adding a more diverse set of MeSH headings targeting examples where MTI has been shown to perform poorly. Machine learning algorithms exceed MTI's performance on MeSH headings that are used very frequently and headings for which the indexing frequency is very low. We find that when we combine the MTI suggestions and the prediction of the learning algorithms, the performance improves compared to any single method for most of the evaluated MeSH headings.

  18. Subjectivity

    Directory of Open Access Journals (Sweden)

    Jesús Vega Encabo

    2015-11-01

    Full Text Available In this paper, I claim that subjectivity is a way of being that is constituted through a set of practices in which the self is subject to the dangers of fictionalizing and plotting her life and self-image. I examine some ways of becoming subject through narratives and through theatrical performance before others. Through these practices, a real and active subjectivity is revealed, capable of self-knowledge and self-transformation. 

  19. Head-to-toe whole-body MRI in psoriatic arthritis, axial spondyloarthritis and healthy subjects

    DEFF Research Database (Denmark)

    Poggenborg, René Panduro; Pedersen, Susanne Juhl; Eshed, Iris

    2015-01-01

    OBJECTIVES: By whole-body MRI (WBMRI), we aimed to examine the frequency and distribution of inflammatory and structural lesions in PsA patients, SpA patients and healthy subjects (HSs), to introduce global WBMRI inflammation/damage scores, and to assess WBMRI's reproducibility and correlation...... of inflammation and structural damage were constructed, and WBMRI findings were compared with clinical measures and convMRI (SpA/HS: spine and SI joints; PsA/HS: hand). RESULTS: The readability (92-100%) and reproducibility (intrareader intraclass correlation coefficient: 0.62-1.0) were high in spine/SI joint......-15]} and SpA [8 (IQR 2-14)] than in HSs [2.5 (IQR 1-4.5)], both P structural damage scores (erosion, fat infiltration and ankylosis) were higher in SpA [7 (IQR 3-12)] than HSs [1.5 (IQR 0-4.5)], P = 0.012. Correlations between WBMRI and convMRI spine and SI joint scores were ρ = 0...

  20. MeSH indexing based on automatically generated summaries.

    Science.gov (United States)

    Jimeno-Yepes, Antonio J; Plaza, Laura; Mork, James G; Aronson, Alan R; Díaz, Alberto

    2013-06-26

    MEDLINE citations are manually indexed at the U.S. National Library of Medicine (NLM) using as reference the Medical Subject Headings (MeSH) controlled vocabulary. For this task, the human indexers read the full text of the article. Due to the growth of MEDLINE, the NLM Indexing Initiative explores indexing methodologies that can support the task of the indexers. Medical Text Indexer (MTI) is a tool developed by the NLM Indexing Initiative to provide MeSH indexing recommendations to indexers. Currently, the input to MTI is MEDLINE citations, title and abstract only. Previous work has shown that using full text as input to MTI increases recall, but decreases precision sharply. We propose using summaries generated automatically from the full text for the input to MTI to use in the task of suggesting MeSH headings to indexers. Summaries distill the most salient information from the full text, which might increase the coverage of automatic indexing approaches based on MEDLINE. We hypothesize that if the results were good enough, manual indexers could possibly use automatic summaries instead of the full texts, along with the recommendations of MTI, to speed up the process while maintaining high quality of indexing results. We have generated summaries of different lengths using two different summarizers, and evaluated the MTI indexing on the summaries using different algorithms: MTI, individual MTI components, and machine learning. The results are compared to those of full text articles and MEDLINE citations. Our results show that automatically generated summaries achieve similar recall but higher precision compared to full text articles. Compared to MEDLINE citations, summaries achieve higher recall but lower precision. Our results show that automatic summaries produce better indexing than full text articles. Summaries produce similar recall to full text but much better precision, which seems to indicate that automatic summaries can efficiently capture the most

  1. Activation of biceps femoris long head reduces tibiofemoral anterior shear force and tibial internal rotation torque in healthy subjects.

    Science.gov (United States)

    Azmi, Nur Liyana; Ding, Ziyun; Xu, Rui; Bull, Anthony M J

    2018-01-01

    The anterior cruciate ligament (ACL) provides resistance to tibial internal rotation torque and anterior shear at the knee. ACL deficiency results in knee instability. Optimisation of muscle contraction through functional electrical stimulation (FES) offers the prospect of mitigating the destabilising effects of ACL deficiency. The hypothesis of this study is that activation of the biceps femoris long head (BFLH) reduces the tibial internal rotation torque and the anterior shear force at the knee. Gait data of twelve healthy subjects were measured with and without the application of FES and taken as inputs to a computational musculoskeletal model. The model was used to investigate the optimum levels of BFLH activation during FES gait in reducing the anterior shear force to zero. This study found that FES significantly reduced the tibial internal rotation torque at the knee during the stance phase of gait (p = 0.0322) and the computational musculoskeletal modelling revealed that a mean BFLH activation of 20.8% (±8.4%) could reduce the anterior shear force to zero. At the time frame when the anterior shear force was zero, the internal rotation torque was reduced by 0.023 ± 0.0167 Nm/BW, with a mean 188% reduction across subjects (p = 0.0002). In conclusion, activation of the BFLH is able to reduce the tibial internal rotation torque and the anterior shear force at the knee in healthy control subjects. This should be tested on ACL deficient subject to consider its effect in mitigating instability due to ligament deficiency. In future clinical practice, activating the BFLH may be used to protect ACL reconstructions during post-operative rehabilitation, assist with residual instabilities post reconstruction, and reduce the need for ACL reconstruction surgery in some cases.

  2. DeepMeSH: deep semantic representation for improving large-scale MeSH indexing.

    Science.gov (United States)

    Peng, Shengwen; You, Ronghui; Wang, Hongning; Zhai, Chengxiang; Mamitsuka, Hiroshi; Zhu, Shanfeng

    2016-06-15

    Medical Subject Headings (MeSH) indexing, which is to assign a set of MeSH main headings to citations, is crucial for many important tasks in biomedical text mining and information retrieval. Large-scale MeSH indexing has two challenging aspects: the citation side and MeSH side. For the citation side, all existing methods, including Medical Text Indexer (MTI) by National Library of Medicine and the state-of-the-art method, MeSHLabeler, deal with text by bag-of-words, which cannot capture semantic and context-dependent information well. We propose DeepMeSH that incorporates deep semantic information for large-scale MeSH indexing. It addresses the two challenges in both citation and MeSH sides. The citation side challenge is solved by a new deep semantic representation, D2V-TFIDF, which concatenates both sparse and dense semantic representations. The MeSH side challenge is solved by using the 'learning to rank' framework of MeSHLabeler, which integrates various types of evidence generated from the new semantic representation. DeepMeSH achieved a Micro F-measure of 0.6323, 2% higher than 0.6218 of MeSHLabeler and 12% higher than 0.5637 of MTI, for BioASQ3 challenge data with 6000 citations. The software is available upon request. zhusf@fudan.edu.cn Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.

  3. Annotating patents with Medline MeSH codes via citation mapping.

    Science.gov (United States)

    Griffin, Thomas D; Boyer, Stephen K; Councill, Isaac G

    2010-01-01

    Both patents and Medline are important document collections for discovering new relationships between chemicals and biology, searching for prior art for patent applications and retrieving background knowledge for current research activities. Finding relevance to a topic within patents is often made difficult by poor categorization, badly written descriptions, and even intentional obfuscation. Unlike patents, the Medline corpus has Medical Subject Heading (MeSH) keywords manually added to their articles, giving a medically relevant taxonomy to the 18 million article abstracts. Our work attempts to accurately recognize the citations made in patents to Medline-indexed articles, linking them to their corresponding PubMed ID and exploiting the associated MeSH to enhance patent search by annotating the referencing patents with their Medline citations' MeSH codes. The techniques, system features, and benefits are explained.

  4. A comparative study of the origin, structure, and indexing language of the Persian and English keywords of articles indexed in the IranMedex database and their compliance with the Persian medical thesaurus and Medical Subject Headings.

    Science.gov (United States)

    Parsaei-Mohammadi, Parastoo; Ghasemi, Ali Hossein; Hassanzadeh-Beheshtabad, Raziyeh

    2017-01-01

    In the present era, thesauri as tools in indexing play an effective role in integrating retrieval preventing fragmentation as well as a multiplicity of terminologies and also in providing information content of documents. This study aimed to investigate the keywords of articles indexed in IranMedex in terms of origin, structure and indexing situation and their Compliance with the Persian Medical Thesaurus and Medical Subject Headings (MeSH). This study is an applied research, and a survey has been conducted. Statistical population includes 32,850 Persian articles which are indexed in the IranMedex during the years 1385-1391. 379 cases were selected as sample of the study. Data collection was done using a checklist. In analyzing the findings, the SPSS Software were used. Although there was no significant difference in terms of indexing origin between the proportion of different types of the Persian and English keywords of articles indexed in the IranMedex, the compliance rates of the Persian and English keywords with the Persian medical thesaurus and MeSH were different in different years. In the meantime, the structure of keywords is leaning more towards phrase structure, and a single word structure and the majority of keywords are selected from the titles and abstracts. The authors' familiarity with the thesauri and controlled tools causes homogeneity in assigning keywords and also provides more precise, faster, and easier retrieval of the keywords. It's suggested that a mixture of natural and control languages to be used in this database in order to reach more comprehensive results.

  5. The video head impulse test (vHIT of semicircular canal function – age dependent normative values of VOR gain in healthy subjects

    Directory of Open Access Journals (Sweden)

    Leigh Andrew McGarvie

    2015-07-01

    Full Text Available Background/Hypothesis. The video Head Impulse Test (vHIT is now widely used to test the function of each of the six semicircular canals individually by measuring the eye rotation response to an abrupt head rotation in the plane of the canal. The main measure of canal adequacy is the ratio of the eye movement response to the head movement stimulus i.e. the gain of the vestibulo-ocular reflex (VOR. However there is a need for normative data about how VOR gain is affected by age and also by head velocity, to allow the response of any particular patient to be compared to response of healthy subjects in their age range. In this study we determined for all six semicircular canals, normative values of VOR gain, for each canal across a range of head velocities, for healthy subjects in each decade of life.Study Design. The VOR gain was measured for all canals across a range of head velocities for at least 10 healthy subjects in decade age bands: 10-19, 20-29, 30-39, 40-49, 50-59, 60-69, 70-79, 80-89. Methods. The compensatory eye movement response to a small, unpredictable, abrupt head rotation (head impulse was measured by the ICS Impulse prototype system. The same operator delivered every impulse to every subject. Results. VOR gain decreased at high head velocities, but was largely unaffected by age into the 80-89 year age group. There were some small but systematic differences between the two directions of head rotation, which appear to be largely due to the fact that in this study only the right eye was measured. The results are considered in relation to recent evidence about the effect of age on VOR performance.Conclusion. These normative values allow the results of any particular patient to be compared to the values of healthy people in their age range and so allow, for example, detection of whether a patient has a bilateral vestibular loss. VOR gain, as measured directly by the eye movement response to head rotation, seems largely unaffected by

  6. Characterization of the mechanism of drug-drug interactions from PubMed using MeSH terms

    OpenAIRE

    Lu, Yin; Figler, Bryan; Huang, Hong; Tu, Yi-Cheng; Wang, Ju; Cheng, Feng

    2017-01-01

    Identifying drug-drug interaction (DDI) is an important topic for the development of safe pharmaceutical drugs and for the optimization of multidrug regimens for complex diseases such as cancer and HIV. There have been about 150,000 publications on DDIs in PubMed, which is a great resource for DDI studies. In this paper, we introduced an automatic computational method for the systematic analysis of the mechanism of DDIs using MeSH (Medical Subject Headings) terms from PubMed literature. MeSH ...

  7. [Correlation of subjective and objective assessment of vaginal prolapse surgery - secondary analysis of randomized controlled study in patients with pelvic floor injury treated with vaginal mesh or with sacrospinous ligament fixation].

    Science.gov (United States)

    Švabík, K; El Haddad, R; Mašata, J; Hubka, P; Martan, A

    2015-10-01

    We had provided secondary analysis of our randomized controlled study comparing vaginal mesh with sacrospinous fixation for vaginal prolapse. We correlated data from subjective and objective assessment. Secondly we had provided correlations results of subjective and objective assessment between patient with anatomical failure and those without. The aim of this analysis was to provide correlation between objective and subjective outcome measures. Subanalysis of randomized controlled study. Obstetric Gynecology Department, First Faculty of Medicine of Charles University and General University Hospital in Prague. This is secondary analysis of single center randomized controlled study comparing two standard procedures for vaginal prolapse after hysterectomy in patients with levator avulsion injury. We had analyzed pre- and postoperative subjective POPDI score (Pelvic Organ Prolapse Distress Inventory) and correlated this score with most prolapsed portion of vaginal wall. We had compared all vaginal compartments using POPQ (Pelvic Organ Prolapse Quantification): anterior wall with point Ba, apical with point C, and posterior with point Bp. Subsequently we compared subjective POPDI score in group of patients with anatomical failure and those without. We had included in randomized study 70 women. Mean preoperative POPDI score was 65.25 (3.57-200). We didnt found any correlation between subjective score and objective assessment in preoperative data: POPDI vs. Ba (p = 0.75) POPDI vs. C (p = 0.57) a POPDI vs. Bp (p = 0.22) and no correlation in postoperative assessment. Postoperative POPDI score decreased to 26.1, but there was no difference in POPDI score in woman with anatomical failure and no failure - 17.4 vs. 23.3 (p = 0.64)CONCLUSION: Secondary analysis of randomized controlled study had shown that objective and subjective assessment have poor correlation. We didnt found any correlation between degree of prolapse and intensity of complains. The large inter

  8. Head repositioning accuracy in patients with neck pain and asymptomatic subjects: concurrent validity, influence of motion speed, motion direction and target distance.

    Science.gov (United States)

    Dugailly, Pierre-Michel; De Santis, Roberta; Tits, Mathieu; Sobczak, Stéphane; Vigne, Anna; Feipel, Véronique

    2015-12-01

    Cervicocephalic kinesthetic deficiencies have been demonstrated in patients with chronic neck pain (NP). On the other hand, authors emphasized the use of different motion speeds for assessing functional impairment of the cervical spine. The objectives of this study were (1) to investigate the head repositioning accuracy in NP patients and control subjects and (2) to assess the influence of target distance, motion speed, motion direction and pain. Seventy-one subjects (36 healthy subjects and 35 NP patients; age 30-55 years) performed the head repositioning test (HRT) at two different speeds for horizontal and vertical movements and at two different distances. For each condition, six consecutive trials were sampled. The study showed the validity and reproducibility of the HRT, confirming a dysfunctional threshold of 4.5°. Normative values of head repositioning error up to 3.6° and 7.1° were identified for healthy and NP subjects, respectively. A distance of 180 cm from the target and a natural motion speed increased HRT accuracy. Repositioning after extension movement showed a significantly larger error in both groups. Intensity, duration of pain as well as pain level did not significantly alter head repositioning error. The assessment of proprioceptive performance in healthy and NP subjects allowed the validation of the HRT. The HRT is a simple, not expensive and fast test, easily implementable in daily practice to assess and monitor treatment and evolution of proprioceptive cervical deficits.

  9. Effects of suboccipital release with craniocervical flexion exercise on craniocervical alignment and extrinsic cervical muscle activity in subjects with forward head posture.

    Science.gov (United States)

    Kim, Bo-Been; Lee, Ji-Hyun; Jeong, Hyo-Jung; Cynn, Heon-Seock

    2016-10-01

    Forward head posture is a head-on-trunk malalignment, which results in musculoskeletal dysfunction and neck pain. To improve forward head posture, both the craniocervical flexion exercise and the suboccipital release technique have been used. The purpose of this study was to compare the immediate effects of craniocervical flexion exercise and suboccipital release combined with craniocervical flexion exercise on craniovertebral angle, cervical flexion and extension range of motion, and the muscle activities of the sternocleidomastoid, anterior scalene, and splenius capitis during craniocervical flexion exercise in subjects with forward head posture. In total, 19 subjects (7 males, 12 females) with forward head posture were recruited using G-power software. Each subject performed craniocervical flexion exercise and suboccipital release combined with craniocervical flexion exercise in random order. After one intervention was performed, the subject took a 20min wash out period to minimize any carry-over effect between interventions. Craniovertebral angle, cervical flexion and extension range of motion, and the muscle activities of the sternocleidomastoid, anterior scalene, and splenius capitis were measured. A one-way, repeated-measures ANOVA was used to assess differences between the effects of the craniocervical flexion exercise and suboccipital release combined with craniocervical flexion exercise interventions in the same group. Craniovertebral angle (pflexion range of motion (pflexion exercise compared to craniocervical flexion exercise alone. The muscle activities of the sternocleidomastoid, anterior scalene, and splenius capitis were significantly lower during suboccipital release combined with craniocervical flexion exercise than during craniocervical flexion exercise alone across all craniocervical flexion exercise phases except the first (all pflexion exercise provided superior benefits relative to craniocervical flexion exercise alone as an intervention for

  10. Hernia Surgical Mesh Implants

    Science.gov (United States)

    ... Procedures Implants and Prosthetics Hernia Surgical Mesh Implants Hernia Surgical Mesh Implants Share Tweet Linkedin Pin it ... between patients and their surgeons. What is a Hernia? A hernia occurs when an organ, intestine or ...

  11. Transcending Library Catalogs: A Comparative Study of Controlled Terms in Library of Congress Subject Headings and User-Generated Tags in LibraryThing for Transgender Books

    Science.gov (United States)

    Adler, Melissa

    2009-01-01

    Perhaps the greatest power of folksonomies, especially when set against controlled vocabularies like the Library of Congress Subject Headings, lies in their capacity to empower user communities to name their own resources in their own terms. This article analyzes the potential and limitations of both folksonomies and controlled vocabularies for…

  12. Comparison of optic area measurement using fundus photography and optical coherence tomography between optic nerve head drusen and control subjects.

    Science.gov (United States)

    Flores-Rodríguez, Patricia; Gili, Pablo; Martín-Ríos, María Dolores; Grifol-Clar, Eulalia

    2013-03-01

    To compare optic disc area measurement between optic nerve head drusen (ONHD) and control subjects using fundus photography, time-domain optical coherence tomography (TD-OCT) and spectral-domain optical coherence tomography (SD-OCT). We also made a comparison between each of the three techniques. We performed our study on 66 eyes (66 patients) with ONHD and 70 healthy control subjects (70 controls) with colour ocular fundus photography at 20º (Zeiss FF 450 IR plus), TD-OCT (Stratus OCT) with the Fast Optic Disc protocol and SD-OCT (Cirrus OCT) with the Optic Disc Cube 200 × 200 protocol for measurement of the optic disc area. The measurements were made by two observers and in each measurement a correction of the image magnification factor was performed. Measurement comparison using the Student's t-test/Mann-Whitney U test, the intraclass correlation coefficient, Pearson/Spearman rank correlation coefficient and the Bland-Altman plot was performed in the statistical analysis. Mean and standard deviation (SD) of the optic disc area in ONHD and in controls was 2.38 (0.54) mm(2) and 2.54 (0.42) mm(2), respectively with fundus photography; 2.01 (0.56) mm(2) and 1.66 (0.37) mm(2), respectively with TD-OCT, and 2.03 (0.49) mm(2) and 1.75 (0.38) mm(2), respectively with SD-OCT. In ONHD and controls, repeatability of optic disc area measurement was excellent with fundus photography and optical coherence tomography (TD-OCT and SD-OCT), but with a low degree of agreement between both techniques. Optic disc area measurement is smaller in ONHD compared to healthy subjects with fundus photography, unlike time-domain and spectral-domain optical coherence tomography in which the reverse is true. Both techniques offer good repeatability, but a low degree of correlation and agreement, which means that optic disc area measurement is not interchangeable or comparable between techniques. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  13. Automatic Assignment of Non-Leaf MeSH Terms to Biomedical Articles.

    Science.gov (United States)

    Kavuluru, Ramakanth; Rios, Anthony

    2015-01-01

    Assigning labels from a hierarchical vocabulary is a well known special case of multi-label classification, often modeled to maximize micro F1-score. However, building accurate binary classifiers for poorly performing labels in the hierarchy can improve both micro and macro F1-scores. In this paper, we propose and evaluate classification strategies involving descendant node instances to build better binary classifiers for non-leaf labels with the use-case of assigning Medical Subject Headings (MeSH) to biomedical articles. Librarians at the National Library of Medicine tag each biomedical article to be indexed by their PubMed information system with terms from the MeSH terminology, a biomedical conceptual hierarchy with over 27,000 terms. Human indexers look at each article's full text to assign a set of most suitable MeSH terms for indexing it. Several recent automated attempts focused on using the article title and abstract text to identify MeSH terms for the corresponding article. Despite these attempts, it is observed that assigning MeSH terms corresponding to certain non-leaf nodes of the MeSH hierarchy is particularly challenging. Non-leaf nodes are very important as they constitute one third of the total number of MeSH terms. Here, we demonstrate the effectiveness of exploiting training examples of descendant terms of non-leaf nodes in improving the performance of conventional classifiers for the corresponding non-leaf MeSH terms. Specifically, we focus on reducing the false positives (FPs) caused due to descendant instances in traditional classifiers. Our methods are able to achieve a relative improvement of 7.5% in macro-F1 score while also increasing the micro-F1 score by 1.6% for a set of 500 non-leaf terms in the MeSH hierarchy. These results strongly indicate the critical role of incorporating hierarchical information in MeSH term prediction. To our knowledge, our effort is the first to demonstrate the role of hierarchical information in improving

  14. MeSHLabeler: improving the accuracy of large-scale MeSH indexing by integrating diverse evidence.

    Science.gov (United States)

    Liu, Ke; Peng, Shengwen; Wu, Junqiu; Zhai, Chengxiang; Mamitsuka, Hiroshi; Zhu, Shanfeng

    2015-06-15

    Medical Subject Headings (MeSHs) are used by National Library of Medicine (NLM) to index almost all citations in MEDLINE, which greatly facilitates the applications of biomedical information retrieval and text mining. To reduce the time and financial cost of manual annotation, NLM has developed a software package, Medical Text Indexer (MTI), for assisting MeSH annotation, which uses k-nearest neighbors (KNN), pattern matching and indexing rules. Other types of information, such as prediction by MeSH classifiers (trained separately), can also be used for automatic MeSH annotation. However, existing methods cannot effectively integrate multiple evidence for MeSH annotation. We propose a novel framework, MeSHLabeler, to integrate multiple evidence for accurate MeSH annotation by using 'learning to rank'. Evidence includes numerous predictions from MeSH classifiers, KNN, pattern matching, MTI and the correlation between different MeSH terms, etc. Each MeSH classifier is trained independently, and thus prediction scores from different classifiers are incomparable. To address this issue, we have developed an effective score normalization procedure to improve the prediction accuracy. MeSHLabeler won the first place in Task 2A of 2014 BioASQ challenge, achieving the Micro F-measure of 0.6248 for 9,040 citations provided by the BioASQ challenge. Note that this accuracy is around 9.15% higher than 0.5724, obtained by MTI. The software is available upon request. © The Author 2015. Published by Oxford University Press.

  15. Enhancing MEDLINE document clustering by incorporating MeSH semantic similarity.

    Science.gov (United States)

    Zhu, Shanfeng; Zeng, Jia; Mamitsuka, Hiroshi

    2009-08-01

    Clustering MEDLINE documents is usually conducted by the vector space model, which computes the content similarity between two documents by basically using the inner-product of their word vectors. Recently, the semantic information of MeSH (Medical Subject Headings) thesaurus is being applied to clustering MEDLINE documents by mapping documents into MeSH concept vectors to be clustered. However, current approaches of using MeSH thesaurus have two serious limitations: first, important semantic information may be lost when generating MeSH concept vectors, and second, the content information of the original text has been discarded. Our new strategy includes three key points. First, we develop a sound method for measuring the semantic similarity between two documents over the MeSH thesaurus. Second, we combine both the semantic and content similarities to generate the integrated similarity matrix between documents. Third, we apply a spectral approach to clustering documents over the integrated similarity matrix. Using various 100 datasets of MEDLINE records, we conduct extensive experiments with changing alternative measures and parameters. Experimental results show that integrating the semantic and content similarities outperforms the case of using only one of the two similarities, being statistically significant. We further find the best parameter setting that is consistent over all experimental conditions conducted. We finally show a typical example of resultant clusters, confirming the effectiveness of our strategy in improving MEDLINE document clustering. Supplementary data are available at Bioinformatics online.

  16. Delaunay mesh generation

    CERN Document Server

    Cheng, Siu-Wing; Shewchuk, Jonathan

    2013-01-01

    Written by authors at the forefront of modern algorithms research, Delaunay Mesh Generation demonstrates the power and versatility of Delaunay meshers in tackling complex geometric domains ranging from polyhedra with internal boundaries to piecewise smooth surfaces. Covering both volume and surface meshes, the authors fully explain how and why these meshing algorithms work.The book is one of the first to integrate a vast amount of cutting-edge material on Delaunay triangulations. It begins with introducing the problem of mesh generation and describing algorithms for constructing Delaunay trian

  17. Relationships among head posture, pain intensity, disability and deep cervical flexor muscle performance in subjects with postural neck pain

    Directory of Open Access Journals (Sweden)

    Arun V. Subbarayalu, PhD

    2017-12-01

    Full Text Available Objectives: Information Technology (IT professionals working with computers gradually develop forward head posture and, as a result, these professionals are susceptible to several neck disorders. This study intended to reveal the relationships between pain intensity, disability, head posture and deep cervical flexor (DCF muscle performance in patients with postural neck pain. Methods: A cross-sectional study was conducted on 84 IT professionals who were diagnosed with postural neck pain. The participants were recruited with a random sampling approach. A Visual Analogue Scale (VAS, the Northwick Park Neck Pain Questionnaire (NPQ, the Modified Head Posture Spinal Curvature Instrument (MHPSCI, and the Stabilizer Pressure Biofeedback Unit were used to measure neck pain intensity, neck disability, head posture, and DCF muscle performance, respectively. Results: The Pearson correlation coefficient revealed a significantly strong positive relationship between the VAS and the NPQ (r = 0.734. The cranio-vertebral (CV angle was found to have a significantly negative correlation with the VAS (r = −0.536 and a weak negative correlation with the NPQ (r = −0.389. Conclusion: This study concluded that a smaller CV angle corresponded to greater neck pain intensity and disability. Furthermore, there is no significant relationship between CV angle and DCF muscle performance, indicating that head posture re-education through postural correction exercises would not completely correct the motor control deficits in DCF muscles. In addition, a suitable exercise regimen that exclusively targets the deep cervical flexor muscle to improve its endurance is warranted. Keywords: Craniovertebral angle, Disability deep cervical flexors muscle performance, Head posture, Postural neck pain

  18. An Adaptive Mesh Algorithm: Mapping the Mesh Variables

    Energy Technology Data Exchange (ETDEWEB)

    Scannapieco, Anthony J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-25

    Both thermodynamic and kinematic variables must be mapped. The kinematic variables are defined on a separate kinematic mesh; it is the duel mesh to the thermodynamic mesh. The map of the kinematic variables is done by calculating the contributions of kinematic variables on the old thermodynamic mesh, mapping the kinematic variable contributions onto the new thermodynamic mesh and then synthesizing the mapped kinematic variables on the new kinematic mesh. In this document the map of the thermodynamic variables will be described.

  19. A Remote-Controlled Airbag Device Can Improve Upper Airway Collapsibility by Producing Head Elevation With Jaw Closure in Normal Subjects Under Propofol Anesthesia.

    Science.gov (United States)

    Ishizaka, Satoru; Moromugi, Shunji; Kobayashi, Masato; Kajihara, Hiroki; Koga, Kazuya; Sugahara, Hirofumi; Ishimatsu, Takakazu; Kurata, Shinji; Kirkness, Jason P; Oi, Kumiko; Ayuse, Takao

    2014-01-01

    Continuous maintenance of an appropriate position of the mandible and head purely by manual manipulation is difficult, although the maneuver can restore airway patency during sleep and anesthesia. The aim of this paper was to examine the effect of head elevation with jaw closure using a remote-controlled airbag device, such as the airbag system, on passive upper airway collapsibility during propofol anesthesia. Seven male subjects were studied. Propofol infusion was used for anesthesia induction and maintenance, with a target blood propofol concentration of 1.5-2 [Formula: see text]g/ml. Nasal mask pressure ([Formula: see text]) was intermittently reduced to evaluate upper airway collapsibility (passive [Formula: see text]) and upstream resistance ([Formula: see text]) at three different head and jaw positions, jaw opening position in the supine position, jaw opening position in the sniffing position with 6-cm head elevation, and jaw closure at a 6-cm height sniffing position. The 6-cm height sniffing position with jaw closure was achieved by an airbag device that was attached to the subject's head-like headgear. Patient demographics, [Formula: see text] and [Formula: see text] in each condition were compared using one-way ANOVA with a post hoc Tukey test. [Formula: see text] was considered significant. We also confirmed the effects of our airbag device on improvement of upper airway collapsibility in three obstructive sleep apnea patients in a clinical study. The combination of 6-cm head elevation with jaw closure using the air-inflatable robotic airbag system decreased upper airway collapsibility ([Formula: see text]-cm H[Formula: see text]O) compared with the baseline position ([Formula: see text]-cm H[Formula: see text]O, [Formula: see text]). In the clinical study, there was improvement of upper airway obstruction in sleep apnea patients, including decreased apnea and hypopnea duration and increased the lowest level of oxygen saturation. We demonstrated that

  20. Effects of repeated snowboard exercise in virtual reality with time lags of visual scene behind body rotation on head stability and subjective slalom run performance in healthy young subjects.

    Science.gov (United States)

    Wada, Yoshiro; Nishiike, Suetaka; Kitahara, Tadashi; Yamanaka, Toshiaki; Imai, Takao; Ito, Taeko; Sato, Go; Matsuda, Kazunori; Kitamura, Yoshiaki; Takeda, Noriaki

    2016-11-01

    After repeated snowboard exercises in the virtual reality (VR) world with increasing time lags in trials 3-8, it is suggested that the adaptation to repeated visual-vestibulosomatosensory conflict in the VR world improved dynamic posture control and motor performance in the real world without the development of motion sickness. The VR technology was used and the effects of repeated snowboard exercise examined in the VR world with time lags between visual scene and body rotation on the head stability and slalom run performance during exercise in healthy subjects. Forty-two healthy young subjects participated in the study. After trials 1 and 2 of snowboard exercise in the VR world without time lag, trials 3-8 were conducted with 0.1, 0.2, 0.3, 0.4, 0.5, and 0.6 s time lags of the visual scene that the computer creates behind board rotation, respectively. Finally, trial 9 was conducted without time lag. Head linear accelerations and subjective slalom run performance were evaluated. The standard deviations of head linear accelerations in inter-aural direction were significantly increased in trial 8, with a time lag of 0.6 s, but significantly decreased in trial 9 without a time lag, compared with those in trial 2 without a time lag. The subjective scores of slalom run performance were significantly decreased in trial 8, with a time lag of 0.6 s, but significantly increased in trial 9 without a time lag, compared with those in trial 2 without a time lag. Motion sickness was not induced in any subjects.

  1. List-Mode PET Motion Correction Using Markerless Head Tracking: Proof-of-Concept With Scans of Human Subject

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Sullivan, Jenna M.; Mulnix, Tim

    2013-01-01

    was time-varying with long drift motions of up to 18 mm and regular step-wise motion of 1–6 mm. The evaluated measures were significantly better for motion-corrected images compared to no MC. The demonstrated system agreed with a commercial integrated system. Motion-corrected images were improved......A custom designed markerless tracking system was demonstrated to be applicable for positron emission tomography (PET) brain imaging. Precise head motion registration is crucial for accurate motion correction (MC) in PET imaging. State-of-the-art tracking systems applied with PET brain imaging rely...... on markers attached to the patient's head. The marker attachment is the main weakness of these systems. A healthy volunteer participating in a cigarette smoking study to image dopamine release was scanned twice for 2 h with $^{11}{\\rm C}$-racolopride on the high resolution research tomograph (HRRT) PET...

  2. Wireless mesh networks

    CERN Document Server

    Held, Gilbert

    2005-01-01

    Wireless mesh networking is a new technology that has the potential to revolutionize how we access the Internet and communicate with co-workers and friends. Wireless Mesh Networks examines the concept and explores its advantages over existing technologies. This book explores existing and future applications, and examines how some of the networking protocols operate.The text offers a detailed analysis of the significant problems affecting wireless mesh networking, including network scale issues, security, and radio frequency interference, and suggests actual and potential solutions for each pro

  3. Importance to include the term superficial musculoaponeurotic system in medical subject headings and in the international anatomical nomenclature.

    Science.gov (United States)

    Ferreira, Lydia Massako; Locali, Rafael Fagionato; Lapin, Guilherme Abbud Franco; Hochman, Bernardo

    2011-06-01

    To investigate the relevance of the term superficial musculoaponeurotic system (SMAS) and demonstrate that this term is important enough to be added to the MeSH database and listed in International Anatomical Nomenclature. Terms related to SMAS were selected from original articles retrieved from the ISI Web of Science and MEDLINE (PubMed) databases. Groups of terms were created to define a search strategy with high-sensitivity and restricted to scientific periodicals devoted to plastic surgery. This study included articles between January 1996 and May 2009, whose titles, abstracts, and keywords were searched for SMAS-related terms and all occurrences were recorded. A total of 126 original articles were retrieved from the main periodicals related to plastic surgery in the referred databases. Of these articles, 51.6% had SMAS-related terms in the abstract only, and 25.4% had SMAS-related terms in both the title and abstract. The term 'superficial musculoaponeurotic system' was present as a keyword in 19.8% of the articles. The most frequent terms were 'SMAS' (71.4%) and superficial musculoaponeurotic system (62.7%). The term SMAS refers to a structure relevant enough to start a discussion about indexing it as a keyword and as an official term in Terminologia Anatomica: International Anatomical Terminology.

  4. On the Performance of Medical Information Retrieval using MeSH Terms – A Survey

    Directory of Open Access Journals (Sweden)

    Swetha S

    2014-09-01

    Full Text Available Internet users have increased everywhere. Searching and retrieving documents is a common thing nowadays. Retrieving related documents from the search engines are difficult task. To retrieve correct documents, knowledge about the search topic is essential. Even though separate search engines are there to retrieve medical documents the users are not familiar with MeSH terms (Medical Subject Heading. So, both the search browser and the MeSH terms have to be integrated to make the search effective and efficient. To implement this integration, SimpleMed and MeSHMed were introduced. The MeSH terms have to be ranked to know how frequently it has been used and to know the importance of the MeSH terms. To rank it a semi – automated tool called MeSHy was developed. The terms were extracted, filtered, ranked and displayed to the user. Classifiers have to be constructed to label the documents as health and non – health. Three strategies were used to classify them. The errors that are commonly done by the users have to be found out. It was calculated based on the queries presented by the user to the search browser.

  5. Geometrically Consistent Mesh Modification

    KAUST Repository

    Bonito, A.

    2010-01-01

    A new paradigm of adaptivity is to execute refinement, coarsening, and smoothing of meshes on manifolds with incomplete information about their geometry and yet preserve position and curvature accuracy. We refer to this collectively as geometrically consistent (GC) mesh modification. We discuss the concept of discrete GC, show the failure of naive approaches, and propose and analyze a simple algorithm that is GC and accuracy preserving. © 2010 Society for Industrial and Applied Mathematics.

  6. Alcohol-associated acute head trauma in human subjects is associated with early deficits in serum ionized Mg and Ca.

    Science.gov (United States)

    Altura, B M; Memon, Z S; Altura, B T; Cracco, R Q

    1995-01-01

    Acute head trauma (AHT) (caused by motor vehicle accidents that did not produce loss of consciousness or observed brain lesions on CT scan, or falls) was found to result in early (1-8 h after injury) serum deficits in ionized magnesium (IMg2+) and ionized calcium (ICa2+) assessed with ion-selective electrodes (ISEs). Total Mg (TMg) and other electrolytes as well as serum biochemical analytes were all within the normal reference ranges. AHT patients with acute alcohol intoxication (BAC > or = 150 mg/dl) or alcohol abuse (BAC > 200 mg/dl) demonstrated deficits (15-35% less than normal) in IMg2+, but serum TMg levels were normal as were electrolytes and serum biochemical analytes. AHT patients with alcohol intoxication or alcohol abuse required hospitalization for 1-3 days prior to release, whereas AHT patients without alcohol intoxication were released in less than 24 h. The ICa2+/IMg2+ ratio, a sign of increased vascular tone and vascular reactivity, was significantly elevated in AHT patients with alcohol intoxication but not in AHT patients without alcohol intoxication or abuse. These serum divalent cation changes early after traumatic brain injury could be of considerable practicable diagnostic value in the assessment of alcohol-associated head injury. Use of ion-selective electrodes to accurately measure IMg2+ could serve as a logical basis for monitoring the response of the body to AHT.

  7. Development and validation of a numerical model of the swine head subjected to open-field blasts

    Science.gov (United States)

    Kalra, A.; Zhu, F.; Feng, K.; Saif, T.; Kallakuri, S.; Jin, X.; Yang, K.; King, A.

    2017-11-01

    A finite element model of the head of a 55-kg Yucatan pig was developed to calculate the incident pressure and corresponding intracranial pressure due to the explosion of 8 lb (3.63 kg) of C4 at three different distances. The results from the model were validated by comparing findings with experimentally obtained data from five pigs at three different blast overpressure levels: low (150 kPa), medium (275 kPa), and high (400 kPa). The peak values of intracranial pressures from numerical model at different locations of the brain such as the frontal, central, left temporal, right temporal, parietal, and occipital regions were compared with experimental values. The model was able to predict the peak pressure with reasonable percentage differences. The differences for peak incident and intracranial pressure values between the simulation results and the experimental values were found to be less than 2.2 and 29.3%, respectively, at all locations other than the frontal region. Additionally, a series of parametric studies shows that the intracranial pressure was very sensitive to sensor locations, the presence of air bubbles, and reflections experienced during the experiments. Further efforts will be undertaken to correlate the different biomechanical response parameters, such as the intracranial pressure gradient, stress, and strain results obtained from the validated model with injured brain locations once the histology data become available.

  8. Documentation for MeshKit - Reactor Geometry (&mesh) Generator

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Rajeev [Argonne National Lab. (ANL), Argonne, IL (United States); Mahadevan, Vijay [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-09-30

    This report gives documentation for using MeshKit’s Reactor Geometry (and mesh) Generator (RGG) GUI and also briefly documents other algorithms and tools available in MeshKit. RGG is a program designed to aid in modeling and meshing of complex/large hexagonal and rectilinear reactor cores. RGG uses Argonne’s SIGMA interfaces, Qt and VTK to produce an intuitive user interface. By integrating a 3D view of the reactor with the meshing tools and combining them into one user interface, RGG streamlines the task of preparing a simulation mesh and enables real-time feedback that reduces accidental scripting mistakes that could waste hours of meshing. RGG interfaces with MeshKit tools to consolidate the meshing process, meaning that going from model to mesh is as easy as a button click. This report is designed to explain RGG v 2.0 interface and provide users with the knowledge and skills to pilot RGG successfully. Brief documentation of MeshKit source code, tools and other algorithms available are also presented for developers to extend and add new algorithms to MeshKit. RGG tools work in serial and parallel and have been used to model complex reactor core models consisting of conical pins, load pads, several thousands of axially varying material properties of instrumentation pins and other interstices meshes.

  9. Objective and subjective image quality of primary and recurrent squamous cell carcinoma on head and neck low-tube-voltage 80-kVp computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Scholtz, Jan-Erik; Kaup, Moritz; Kraft, Johannes; Noeske, Eva-Maria; Schulz, Boris; Burck, Iris; Kerl, J.M.; Bauer, Ralf W.; Lehnert, Thomas; Vogl, Thomas J.; Wichmann, Julian L. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Scheerer, Friedrich [University Hospital Frankfurt, Department of Cranio-Maxillofacial and Plastic Facial Surgery, Frankfurt (Germany); Wagenblast, Jens [University Hospital Frankfurt, Department of Otolaryngology, Head and Neck Surgery, Frankfurt (Germany)

    2015-03-26

    To investigate low-tube-voltage 80-kVp computed tomography (CT) of head and neck primary and recurrent squamous cell carcinoma (SCC) regarding objective and subjective image quality. We retrospectively evaluated 65 patients (47 male, 18 female; mean age: 62.1 years) who underwent head and neck dual-energy CT (DECT) due to biopsy-proven primary (n = 50) or recurrent (n = 15) SCC. Eighty peak kilovoltage and standard blended 120-kVp images were compared. Attenuation and noise of malignancy and various soft tissue structures were measured. Tumor signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was rated by three reviewers using 5-point grading scales regarding overall image quality, lesion delineation, image sharpness, and image noise. Radiation dose was assessed as CT dose index volume (CTDI{sub vol}). Interobserver agreement was calculated using intraclass correlation coefficient (ICC). Mean tumor attenuation (153.8 Hounsfield unit (HU) vs. 97.1 HU), SNR (10.7 vs. 8.3), CNR (8.1 vs. 4.8), and subjective tumor delineation (score, 4.46 vs. 4.13) were significantly increased (all P < 0.001) with 80-kVp acquisition compared to standard blended 120-kVp images. Noise of all measured structures was increased in 80-kVp acquisition (P < 0.001). Overall interobserver agreement was good (ICC, 0.86; 95 % confidence intervals: 0.82-0.89). CTDI{sub vol} was reduced by 48.7 % with 80-kVp acquisition compared to standard DECT (4.85 ± 0.51 vs. 9.94 ± 0.81 mGy cm, P < 0.001). Head and neck CT with low-tube-voltage 80-kVp acquisition provides increased tumor delineation, SNR, and CNR for CT imaging of primary and recurrent SCC compared to standard 120-kVp acquisition with an accompanying significant reduction of radiation exposure. (orig.)

  10. Scored Patient-Generated Subjective Global Assessment, albumin and transferrin for nutritional assessment of gastrostomy fed head or neck cancer patients.

    Science.gov (United States)

    Correira Pereira, Marta Alexandra; Santos, Carla Adriana; Almeida Brito, José; Fonseca, Jorge

    2014-02-01

    Gastrostomy fed head or neck cancer patients frequently have impaired speech capacities. Enteral feeding teams frequently depend on laboratorial or anthropometrical parameters for nutritional assessment. In these patients, this study aimed to evaluate: (1) the practicability of Scored - Patient-Generated Subjective Global Assessment (PG-SGA); (2) their nutritional status using the Scored-PG-SGA; (3) association of serum albumin and transferrin values to the nutritional status rating using PG-SGA. On adult outpatients with head or neck cancer under prolonged (> 1 month) gastrostomy feeding, Scored-PGSGA, albumin and transferrin were evaluated during the same appointment. Scored-PG-SGA was easily feasible in 42 patients, even in patients with speech difficulties. Twenty-five patients were moderately/severely undernourished (PG-SGA/B+C). Scored-PG-SGA rated 41 patients as ≥ 2, thus needing nutritional/ pharmacologic intervention. Albumin was low in 13 patients. Transferrin was low in 19 patients. Average albumin and transferrin in moderately/severely undernourished patients (PG-SGA/B+C) was significantly lower than in well-nourished (PG-SGA/A). There was association between Scored- PG-SGA rating, albumin and transferrin. In PEG fed head or neck cancer patients, PGSGA was practicable and useful, even in patients with impaired speaking skills. Most patients displayed moderate/severe malnutrition (PG-SGA/B+C). Scored-PG-SGA rated 41 patients as needing for nutritional/pharmacological intervention. Scored-PG-SGA should be systematically included in the evaluation of these patients. In these patients, albumin and transferrin levels showed relation with Scored-PG-SGA and should be considered as nutritional biomarkers. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  11. Incidence of head and neck squamous cell carcinoma among subjects at high risk of lung cancer: results from the Pittsburgh Lung Screening Study.

    Science.gov (United States)

    Dixit, Ronak; Weissfeld, Joel L; Wilson, David O; Balogh, Paula; Sufka, Pamela; Siegfried, Jill M; Grandis, Jennifer R; Diergaarde, Brenda

    2015-05-01

    Earlier detection and diagnosis of head and neck squamous cell carcinoma (HNSCC) should lead to improved outcomes. However, to the authors' knowledge, no effective screening strategy has been identified to date. In the current study, the authors evaluated whether it would be useful to screen subjects targeted for lung cancer screening for HNSCC as well. Medical records, death certificates, and cancer registry and questionnaire data were used to determine the number of observed incident HNSCC cases in the Pittsburgh Lung Screening Study (PLuSS), a cohort of current and former smokers aged ≥50 years with a ≥12.5 pack-year smoking history. The expected number of cases was estimated using stratum-specific incidence rates obtained from Surveillance, Epidemiology, and End Results data for 2000 through 2011. The standardized incidence ratio was calculated to examine the difference between the observed and expected number of cases. Of the 3587 at-risk participants in the PLuSS, 23 (0.64%) developed HNSCC over a total of 32,201 person-years of follow-up. This finding was significantly higher than expected based on incidence rates obtained from the Surveillance, Epidemiology, and End Results program (13.70 cases expected; standardized incidence ratio, 1.68 [95% confidence interval, 1.06-2.52]). The excess burden of HNSCC in the PLuSS was 28.9 cases per 100,000 person-years. Observed incident cases were significantly more often male, had started smoking at a younger age, smoked more per day, and had more pack-years of smoking than the rest of the PLuSS at-risk participants. The results of the current study provide a rationale for offering head and neck cancer screening along with computed tomography screening for lung cancer. Randomized controlled trials that assess the effectiveness of adding examination of the head and neck area to lung cancer screening programs are warranted. © 2015 American Cancer Society.

  12. Automatic polygon mesh repair and simplification for three-dimensional human modeling

    Science.gov (United States)

    Zhu, Yaolin; Tian, Li; Wan, Taoruan

    2017-07-01

    We present a new approach to repair degenerated and self-intersected mesh of digitized human models, which automatically transforms a raw digitized mesh into a single manifold and closed triangle mesh. The algorithm interactively removes growing neighborhoods of undesired elements and fills resulted surface gaps to yield meshes which subject to user-specified quality criteria. We demonstrate our experimental results by multiple sets of low-quality original models with qualitative measurements compared with a number of existing methods. The results show that the proposed method produces high visual quality meshes with minimal changes of the original mesh appearances.

  13. Experimental Investigation of Cavitation as a Possible Damage Mechanism in Blast-Induced Traumatic Brain Injury in Post-Mortem Human Subject Heads.

    Science.gov (United States)

    Salzar, Robert S; Treichler, Derrick; Wardlaw, Andrew; Weiss, Greg; Goeller, Jacques

    2017-04-15

    The potential of blast-induced traumatic brain injury from the mechanism of localized cavitation of the cerebrospinal fluid (CSF) is investigated. While the mechanism and criteria for non-impact blast-induced traumatic brain injury is still unknown, this study demonstrates that local cavitation in the CSF layer of the cranial volume could contribute to these injuries. The cranial contents of three post-mortem human subject (PMHS) heads were replaced with both a normal saline solution and a ballistic gel mixture with a simulated CSF layer. Each were instrumented with multiple pressure transducers and placed inside identical shock tubes at two different research facilities. Sensor data indicates that cavitation may have occurred in the PMHS models at pressure levels below those for a 50% risk of blast lung injury. This study points to skull flexion, the result of the shock wave on the front of the skull leading to a negative pressure in the contrecoup, as a possible mechanism that contributes to the onset of cavitation. Based on observation of intracranial pressure transducer data from the PMHS model, cavitation onset is thought to occur from approximately a 140 kPa head-on incident blast.

  14. MeshLab: 3D triangular meshes processing and editing

    Science.gov (United States)

    Cignoni, P.; Callieri, M.; Corsini, M.; Dellepiane, M.; Ganovelli, F.; Ranzuglia, G.

    2017-09-01

    MeshLab processes and edits 3D triangular meshes. It includes tools for editing, cleaning, healing, inspecting, rendering, texturing and converting meshes, and offers features for processing raw data produced by 3D digitization tools and devices and for preparing models for 3D printing.

  15. Reduced Sympathetic Response to Head-Up Tilt in Subjects with Mild Cognitive Impairment or Mild Alzheimer's Dementia

    Directory of Open Access Journals (Sweden)

    Marte Rognstad Mellingsæter

    2015-03-01

    Full Text Available Background: Hemodynamic control was compared in patients with mild cognitive impairment (MCI or mild Alzheimer's dementia (AD as well as in healthy elderly subjects. Methods: Noninvasive, continuous hemodynamic recordings were obtained from 14 patients and 48 controls during supine rest (tilt of 30 and 70°. Cardiac output, end-diastolic volume, total peripheral resistance, heart rate variability (HRV, systolic blood pressure variability (SBPV, and baroreceptor sensitivity were calculated. Results: At 70° tilt, the HRV indices differed significantly, with higher high-frequency (HF variability as well as lower low-frequency (LF variability and LF/HF ratios in the patients. The patients had significantly lower SBPV in the LF range at 30° tilt. Conclusions: The results indicate a poorer sympathetic response to orthostatic stress in MCI and mild AD.

  16. Advanced numerical methods in mesh generation and mesh adaptation

    Energy Technology Data Exchange (ETDEWEB)

    Lipnikov, Konstantine [Los Alamos National Laboratory; Danilov, A [MOSCOW, RUSSIA; Vassilevski, Y [MOSCOW, RUSSIA; Agonzal, A [UNIV OF LYON

    2010-01-01

    Numerical solution of partial differential equations requires appropriate meshes, efficient solvers and robust and reliable error estimates. Generation of high-quality meshes for complex engineering models is a non-trivial task. This task is made more difficult when the mesh has to be adapted to a problem solution. This article is focused on a synergistic approach to the mesh generation and mesh adaptation, where best properties of various mesh generation methods are combined to build efficiently simplicial meshes. First, the advancing front technique (AFT) is combined with the incremental Delaunay triangulation (DT) to build an initial mesh. Second, the metric-based mesh adaptation (MBA) method is employed to improve quality of the generated mesh and/or to adapt it to a problem solution. We demonstrate with numerical experiments that combination of all three methods is required for robust meshing of complex engineering models. The key to successful mesh generation is the high-quality of the triangles in the initial front. We use a black-box technique to improve surface meshes exported from an unattainable CAD system. The initial surface mesh is refined into a shape-regular triangulation which approximates the boundary with the same accuracy as the CAD mesh. The DT method adds robustness to the AFT. The resulting mesh is topologically correct but may contain a few slivers. The MBA uses seven local operations to modify the mesh topology. It improves significantly the mesh quality. The MBA method is also used to adapt the mesh to a problem solution to minimize computational resources required for solving the problem. The MBA has a solid theoretical background. In the first two experiments, we consider the convection-diffusion and elasticity problems. We demonstrate the optimal reduction rate of the discretization error on a sequence of adaptive strongly anisotropic meshes. The key element of the MBA method is construction of a tensor metric from hierarchical edge

  17. Analysis by NASA's VESGEN Software of Retinal Blood Vessels in Human Subjects Undergoing Head-Down Tilt During 70-Day Bed Rest

    Science.gov (United States)

    Vyas, Ruchi J.; Murray, Matthew C.; Predovic, Marina; Lim, Shiyin; Askin, Kayleigh N.; Vizzeri, Gianmarco; Taibbi, Giovanni; Mason, Sara Stroble; Zanello, Susana B.; Young, Millenia; hide

    2017-01-01

    Significant risks for visual impairment associated with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions [1]. We hypothesize that microgravity-induced fluid shifts result in pathological changes within blood vessels of the retina that precede development of visual and other ocular impairments. Potential contributions of retinal vascular remodeling to VIIP etiology are therefore being investigated for two studies in 30deg infrared (IR) Heidelberg Spectralis(Registered Trademark) images with NASA's innovative VESsel GENeration Analysis (VESGEN) software [2,3]. The retrospective studies include: (1) before, during and after (pre, mid and post) 6º head-down tilt (HDT) in human subjects during 70 days of bed rest, and (2) before and after missions to the International Space Station (ISS) by U.S. crew members. Results for both studies are almost complete. A preliminary example for HDT is described below.

  18. The mesh controversy [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Joshua A. Cohn

    2016-09-01

    Full Text Available Pelvic organ prolapse and stress urinary incontinence are common conditions for which approximately 11% of women will undergo surgical intervention in their lifetime. The use of vaginal mesh for pelvic organ prolapse and stress urinary incontinence rose rapidly in the early 2000s as over 100 mesh products were introduced into the clinical armamentarium with little regulatory oversight for their use. US Food and Drug Administration Public Health Notifications in 2008 and 2011, as well as reclassification of transvaginal mesh for prolapse to class III in early 2016, were a response to debilitating complications associated with transvaginal mesh placement in many women. The midurethral sling has not been subject to the same reclassification and continues to be endorsed as the “gold standard” for surgical management of stress urinary incontinence by subspecialty societies. However, litigators have not differentiated between mesh for prolapse and mesh for incontinence. As such, all mesh, including that placed for stress urinary incontinence, faces continued controversy amidst an uncertain future. In this article, we review the background of the mesh controversy, recent developments, and the anticipated role of mesh in surgery for prolapse and stress urinary incontinence going forward.

  19. Head Start.

    Science.gov (United States)

    Greenman, Geri

    2000-01-01

    Discusses an art project in which students created drawings of mop heads. Explains that the approach of drawing was more important than the subject. States that the students used the chiaroscuro technique, used by Rembrandt and Caravaggio, in which light appears out of the darkness. (CMK)

  20. MeSHy: Mining unanticipated PubMed information using frequencies of occurrences and concurrences of MeSH terms.

    Science.gov (United States)

    Theodosiou, T; Vizirianakis, I S; Angelis, L; Tsaftaris, A; Darzentas, N

    2011-12-01

    PubMed is the most widely used database of biomedical literature. To the detriment of the user though, the ranking of the documents retrieved for a query is not content-based, and important semantic information in the form of assigned Medical Subject Headings (MeSH) terms is not readily presented or productively utilized. The motivation behind this work was the discovery of unanticipated information through the appropriate ranking of MeSH term pairs and, indirectly, documents. Such information can be useful in guiding novel research and following promising trends. A web-based tool, called MeSHy, was developed implementing a mainly statistical algorithm. The algorithm takes into account the frequencies of occurrences, concurrences, and the semantic similarities of MeSH terms in retrieved PubMed documents to create MeSH term pairs. These are then scored and ranked, focusing on their unexpectedly frequent or infrequent occurrences. MeSHy presents results through an online interactive interface facilitating further manipulation through filtering and sorting. The results themselves include the MeSH term pairs, along with MeSH categories, the score, and document IDs, all of which are hyperlinked for convenience. To highlight the applicability of the tool, we report the findings of an expert in the pharmacology field on querying the molecularly-targeted drug imatinib and nutrition-related flavonoids. To the best of our knowledge, MeSHy is the first publicly available tool able to directly provide such a different perspective on the complex nature of published work. Implemented in Perl and served by Apache2 at http://bat.ina.certh.gr/tools/meshy/ with all major browsers supported. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. 50 CFR 300.110 - Mesh size.

    Science.gov (United States)

    2010-10-01

    ... direction perpendicular to the plane of the net. (iii) The gauge may be inserted into the mesh opening... the resistance of the mesh. (3) Selection of meshes to be measured. (i) Meshes to be measured will...

  2. Characterization of the mechanism of drug-drug interactions from PubMed using MeSH terms.

    Directory of Open Access Journals (Sweden)

    Yin Lu

    Full Text Available Identifying drug-drug interaction (DDI is an important topic for the development of safe pharmaceutical drugs and for the optimization of multidrug regimens for complex diseases such as cancer and HIV. There have been about 150,000 publications on DDIs in PubMed, which is a great resource for DDI studies. In this paper, we introduced an automatic computational method for the systematic analysis of the mechanism of DDIs using MeSH (Medical Subject Headings terms from PubMed literature. MeSH term is a controlled vocabulary thesaurus developed by the National Library of Medicine for indexing and annotating articles. Our method can effectively identify DDI-relevant MeSH terms such as drugs, proteins and phenomena with high accuracy. The connections among these MeSH terms were investigated by using co-occurrence heatmaps and social network analysis. Our approach can be used to visualize relationships of DDI terms, which has the potential to help users better understand DDIs. As the volume of PubMed records increases, our method for automatic analysis of DDIs from the PubMed database will become more accurate.

  3. Characterization of the mechanism of drug-drug interactions from PubMed using MeSH terms.

    Science.gov (United States)

    Lu, Yin; Figler, Bryan; Huang, Hong; Tu, Yi-Cheng; Wang, Ju; Cheng, Feng

    2017-01-01

    Identifying drug-drug interaction (DDI) is an important topic for the development of safe pharmaceutical drugs and for the optimization of multidrug regimens for complex diseases such as cancer and HIV. There have been about 150,000 publications on DDIs in PubMed, which is a great resource for DDI studies. In this paper, we introduced an automatic computational method for the systematic analysis of the mechanism of DDIs using MeSH (Medical Subject Headings) terms from PubMed literature. MeSH term is a controlled vocabulary thesaurus developed by the National Library of Medicine for indexing and annotating articles. Our method can effectively identify DDI-relevant MeSH terms such as drugs, proteins and phenomena with high accuracy. The connections among these MeSH terms were investigated by using co-occurrence heatmaps and social network analysis. Our approach can be used to visualize relationships of DDI terms, which has the potential to help users better understand DDIs. As the volume of PubMed records increases, our method for automatic analysis of DDIs from the PubMed database will become more accurate.

  4. Parallel Adaptive Mesh Refinement

    Energy Technology Data Exchange (ETDEWEB)

    Diachin, L; Hornung, R; Plassmann, P; WIssink, A

    2005-03-04

    As large-scale, parallel computers have become more widely available and numerical models and algorithms have advanced, the range of physical phenomena that can be simulated has expanded dramatically. Many important science and engineering problems exhibit solutions with localized behavior where highly-detailed salient features or large gradients appear in certain regions which are separated by much larger regions where the solution is smooth. Examples include chemically-reacting flows with radiative heat transfer, high Reynolds number flows interacting with solid objects, and combustion problems where the flame front is essentially a two-dimensional sheet occupying a small part of a three-dimensional domain. Modeling such problems numerically requires approximating the governing partial differential equations on a discrete domain, or grid. Grid spacing is an important factor in determining the accuracy and cost of a computation. A fine grid may be needed to resolve key local features while a much coarser grid may suffice elsewhere. Employing a fine grid everywhere may be inefficient at best and, at worst, may make an adequately resolved simulation impractical. Moreover, the location and resolution of fine grid required for an accurate solution is a dynamic property of a problem's transient features and may not be known a priori. Adaptive mesh refinement (AMR) is a technique that can be used with both structured and unstructured meshes to adjust local grid spacing dynamically to capture solution features with an appropriate degree of resolution. Thus, computational resources can be focused where and when they are needed most to efficiently achieve an accurate solution without incurring the cost of a globally-fine grid. Figure 1.1 shows two example computations using AMR; on the left is a structured mesh calculation of a impulsively-sheared contact surface and on the right is the fuselage and volume discretization of an RAH-66 Comanche helicopter [35]. Note the

  5. Compensating for literature annotation bias when predicting novel drug-disease relationships through Medical Subject Heading Over-representation Profile (MeSHOP) similarity.

    Science.gov (United States)

    Cheung, Warren A; Ouellette, B F Francis; Wasserman, Wyeth W

    2013-01-01

    Using annotations to the articles in MEDLINE®/PubMed®, over six thousand chemical compounds with pharmacological actions have been tracked since 1996. Medical Subject Heading Over-representation Profiles (MeSHOPs) quantitatively leverage the literature associated with biological entities such as diseases or drugs, providing the opportunity to reposition known compounds towards novel disease applications. A MeSHOP is constructed by counting the number of times each medical subject term is assigned to an entity-related research publication in the MEDLINE database and calculating the significance of the count by comparing against the count of the term in a background set of publications. Based on the expectation that drugs suitable for treatment of a disease (or disease symptom) will have similar annotation properties to the disease, we successfully predict drug-disease associations by comparing MeSHOPs of diseases and drugs. The MeSHOP comparison approach delivers an 11% improvement over bibliometric baselines. However, novel drug-disease associations are observed to be biased towards drugs and diseases with more publications. To account for the annotation biases, a correction procedure is introduced and evaluated. By explicitly accounting for the annotation bias, unexpectedly similar drug-disease pairs are highlighted as candidates for drug repositioning research. MeSHOPs are shown to provide a literature-supported perspective for discovery of new links between drugs and diseases based on pre-existing knowledge.

  6. Mesh Algorithms for PDE with Sieve I: Mesh Distribution

    Directory of Open Access Journals (Sweden)

    Matthew G. Knepley

    2009-01-01

    Full Text Available We have developed a new programming framework, called Sieve, to support parallel numerical partial differential equation(s (PDE algorithms operating over distributed meshes. We have also developed a reference implementation of Sieve in C++ as a library of generic algorithms operating on distributed containers conforming to the Sieve interface. Sieve makes instances of the incidence relation, or arrows, the conceptual first-class objects represented in the containers. Further, generic algorithms acting on this arrow container are systematically used to provide natural geometric operations on the topology and also, through duality, on the data. Finally, coverings and duality are used to encode not only individual meshes, but all types of hierarchies underlying PDE data structures, including multigrid and mesh partitions. In order to demonstrate the usefulness of the framework, we show how the mesh partition data can be represented and manipulated using the same fundamental mechanisms used to represent meshes. We present the complete description of an algorithm to encode a mesh partition and then distribute a mesh, which is independent of the mesh dimension, element shape, or embedding. Moreover, data associated with the mesh can be similarly distributed with exactly the same algorithm. The use of a high level of abstraction within the Sieve leads to several benefits in terms of code reuse, simplicity, and extensibility. We discuss these benefits and compare our approach to other existing mesh libraries.

  7. Tesauros y listas de epígrafes: ¿hacia una integración? Thesauri and list of subject headings: towards an integration?

    Directory of Open Access Journals (Sweden)

    Ana María Martínez

    2003-12-01

    Full Text Available Se analizan las semejanzas y diferencias entre los tesauros y las listas de epígrafes, tomando en cuenta el plan de revisión 2003 de la norma estadounidense Z39.19. Esta norma pretende establecer nuevas directrices para todo tipo de vocabulario controlado, en relación con su utilización con nuevas tecnologías. Se concluye que, en efecto, es muy importante revisar toda la normativa referida a los vocabularios controlados, particularmente las de alcance internacional, pero al mismo tiempo se hace necesario tener sumo cuidado en mantener un riguroso control de la terminología, una correcta definición de las relaciones jerárquicas y asociativas y promover la poscoordinación gestionada, en lo posible, mediante sistemas facetados y computarizados.The similarities and differences between thesauri and the lists of subject headings are analyzed, taking into account the work plan for the 2003 revision of the US standard Z39.19. This standard pretends to establish new guidelines for all types of controlled vocabulary in relation to their use with new technologies. We conclude that it is very important to review all the standards for controlled vocabulary, particularly those with international scope, but at the same time, it is necessary to be very careful in maintaining a rigorous control of terminology; a correct definition of hierarchical and associative relationships, and to promote the postcordination, managed, if possible, in faceted and computerized systems.

  8. Improving image retrieval effectiveness via query expansion using MeSH hierarchical structure.

    Science.gov (United States)

    Crespo Azcárate, Mariano; Mata Vázquez, Jacinto; Maña López, Manuel

    2013-01-01

    We explored two strategies for query expansion utilizing medical subject headings (MeSH) ontology to improve the effectiveness of medical image retrieval systems. In order to achieve greater effectiveness in the expansion, the search text was analyzed to identify which terms were most amenable to being expanded. To perform the expansions we utilized the hierarchical structure by which the MeSH descriptors are organized. Two strategies for selecting the terms to be expanded in each query were studied. The first consisted of identifying the medical concepts using the unified medical language system metathesaurus. In the second strategy the text of the query was divided into n-grams, resulting in sequences corresponding to MeSH descriptors. For the evaluation of the system, we used the collection made available by the ImageCLEF organization in its 2011 medical image retrieval task. The main measure of efficiency employed for evaluating the techniques developed was the mean average precision (MAP). Both strategies exceeded the average MAP score in the ImageCLEF 2011 competition (0.1644). The n-gram expansion strategy achieved a MAP of 0.2004, which represents an improvement of 21.89% over the average MAP score in the competition. On the other hand, the medical concepts expansion strategy scored 0.2172 in the MAP, representing a 32.11% improvement. This run won the text-based medical image retrieval task in 2011. Query expansion exploiting the hierarchical structure of the MeSH descriptors achieved a significant improvement in image retrieval systems.

  9. An Adaptive Mesh Algorithm: Mesh Structure and Generation

    Energy Technology Data Exchange (ETDEWEB)

    Scannapieco, Anthony J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-21

    The purpose of Adaptive Mesh Refinement is to minimize spatial errors over the computational space not to minimize the number of computational elements. The additional result of the technique is that it may reduce the number of computational elements needed to retain a given level of spatial accuracy. Adaptive mesh refinement is a computational technique used to dynamically select, over a region of space, a set of computational elements designed to minimize spatial error in the computational model of a physical process. The fundamental idea is to increase the mesh resolution in regions where the physical variables are represented by a broad spectrum of modes in k-space, hence increasing the effective global spectral coverage of those physical variables. In addition, the selection of the spatially distributed elements is done dynamically by cyclically adjusting the mesh to follow the spectral evolution of the system. Over the years three types of AMR schemes have evolved; block, patch and locally refined AMR. In block and patch AMR logical blocks of various grid sizes are overlaid to span the physical space of interest, whereas in locally refined AMR no logical blocks are employed but locally nested mesh levels are used to span the physical space. The distinction between block and patch AMR is that in block AMR the original blocks refine and coarsen entirely in time, whereas in patch AMR the patches change location and zone size with time. The type of AMR described herein is a locally refi ned AMR. In the algorithm described, at any point in physical space only one zone exists at whatever level of mesh that is appropriate for that physical location. The dynamic creation of a locally refi ned computational mesh is made practical by a judicious selection of mesh rules. With these rules the mesh is evolved via a mesh potential designed to concentrate the nest mesh in regions where the physics is modally dense, and coarsen zones in regions where the physics is modally

  10. Surface meshing with curvature convergence

    KAUST Repository

    Li, Huibin

    2014-06-01

    Surface meshing plays a fundamental role in graphics and visualization. Many geometric processing tasks involve solving geometric PDEs on meshes. The numerical stability, convergence rates and approximation errors are largely determined by the mesh qualities. In practice, Delaunay refinement algorithms offer satisfactory solutions to high quality mesh generations. The theoretical proofs for volume based and surface based Delaunay refinement algorithms have been established, but those for conformal parameterization based ones remain wide open. This work focuses on the curvature measure convergence for the conformal parameterization based Delaunay refinement algorithms. Given a metric surface, the proposed approach triangulates its conformal uniformization domain by the planar Delaunay refinement algorithms, and produces a high quality mesh. We give explicit estimates for the Hausdorff distance, the normal deviation, and the differences in curvature measures between the surface and the mesh. In contrast to the conventional results based on volumetric Delaunay refinement, our stronger estimates are independent of the mesh structure and directly guarantee the convergence of curvature measures. Meanwhile, our result on Gaussian curvature measure is intrinsic to the Riemannian metric and independent of the embedding. In practice, our meshing algorithm is much easier to implement and much more efficient. The experimental results verified our theoretical results and demonstrated the efficiency of the meshing algorithm. © 2014 IEEE.

  11. Overlap Areas of a Square Box on a Square Mesh

    Science.gov (United States)

    2017-04-01

    ARL-TN-0818 ● APR 2017 US Army Research Laboratory Overlap Areas of a Square Box on a Square Mesh by James U Cazamias...originator. ARL-TN-0818 ● APR 2017 US Army Research Laboratory Overlap Areas of a Square Box on a Square Mesh by James U Cazamias...no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control

  12. Improving MeSH classification of biomedical articles using citation contexts.

    Science.gov (United States)

    Aljaber, Bader; Martinez, David; Stokes, Nicola; Bailey, James

    2011-10-01

    Medical Subject Headings (MeSH) are used to index the majority of databases generated by the National Library of Medicine. Essentially, MeSH terms are designed to make information, such as scientific articles, more retrievable and assessable to users of systems such as PubMed. This paper proposes a novel method for automating the assignment of biomedical publications with MeSH terms that takes advantage of citation references to these publications. Our findings show that analysing the citation references that point to a document can provide a useful source of terms that are not present in the document. The use of these citation contexts, as they are known, can thus help to provide a richer document feature representation, which in turn can help improve text mining and information retrieval applications, in our case MeSH term classification. In this paper, we also explore new methods of selecting and utilising citation contexts. In particular, we assess the effect of weighting the importance of citation terms (found in the citation contexts) according to two aspects: (i) the section of the paper they appear in and (ii) their distance to the citation marker. We conduct intrinsic and extrinsic evaluations of citation term quality. For the intrinsic evaluation, we rely on the UMLS Metathesaurus conceptual database to explore the semantic characteristics of the mined citation terms. We also analyse the "informativeness" of these terms using a class-entropy measure. For the extrinsic evaluation, we run a series of automatic document classification experiments over MeSH terms. Our experimental evaluation shows that citation contexts contain terms that are related to the original document, and that the integration of this knowledge results in better classification performance compared to two state-of-the-art MeSH classification systems: MeSHUP and MTI. Our experiments also demonstrate that the consideration of Section and Distance factors can lead to statistically

  13. MeSH key terms for validation and annotation of gene expression clusters

    Energy Technology Data Exchange (ETDEWEB)

    Rechtsteiner, A. (Andreas); Rocha, L. M. (Luis Mateus)

    2004-01-01

    Integration of different sources of information is a great challenge for the analysis of gene expression data, and for the field of Functional Genomics in general. As the availability of numerical data from high-throughput methods increases, so does the need for technologies that assist in the validation and evaluation of the biological significance of results extracted from these data. In mRNA assaying with microarrays, for example, numerical analysis often attempts to identify clusters of co-expressed genes. The important task to find the biological significance of the results and validate them has so far mostly fallen to the biological expert who had to perform this task manually. One of the most promising avenues to develop automated and integrative technology for such tasks lies in the application of modern Information Retrieval (IR) and Knowledge Management (KM) algorithms to databases with biomedical publications and data. Examples of databases available for the field are bibliographic databases c ntaining scientific publications (e.g. MEDLINE/PUBMED), databases containing sequence data (e.g. GenBank) and databases of semantic annotations (e.g. the Gene Ontology Consortium and Medical Subject Headings (MeSH)). We present here an approach that uses the MeSH terms and their concept hierarchies to validate and obtain functional information for gene expression clusters. The controlled and hierarchical MeSH vocabulary is used by the National Library of Medicine (NLM) to index all the articles cited in MEDLINE. Such indexing with a controlled vocabulary eliminates some of the ambiguity due to polysemy (terms that have multiple meanings) and synonymy (multiple terms have similar meaning) that would be encountered if terms would be extracted directly from the articles due to differing article contexts or author preferences and background. Further, the hierarchical organization of the MeSH terms can illustrate the conceptuallfunctional relationships of genes

  14. Quadrilateral finite element mesh coarsening

    Science.gov (United States)

    Staten, Matthew L; Dewey, Mark W; Benzley, Steven E

    2012-10-16

    Techniques for coarsening a quadrilateral mesh are described. These techniques include identifying a coarsening region within the quadrilateral mesh to be coarsened. Quadrilateral elements along a path through the coarsening region are removed. Node pairs along opposite sides of the path are identified. The node pairs along the path are then merged to collapse the path.

  15. Mesh surfaces for reflector applications

    Science.gov (United States)

    Kauffman, Frank

    1989-01-01

    The topics of mesh reflectors, methods of analysis, measurements, problems of current interest, and future research, are those which should be addressed in assessing the current state of metallic mesh technology for spaceborne reflector antennas. The study of the properties of the conducting mesh material is discussed. To calculate the radiation patterns of antennas with conducting mesh reflectors, the electromagnetic properties of the mesh material must be integrated into an appropriate reflector antenna computer code. Such a code would take into account such factors as the curvature of the reflector surface, the radiation pattern(s) of the feed(s), etc. Many organizations have developed their own codes for these calculations. An excellent example of such a code is the one developed by Rahmat-Samii and Lee.

  16. Intracranial hemorrhage alters scalp potential distribution in bioimpedance cerebral monitoring: Preliminary results from FEM simulation on a realistic head model and human subjects.

    Science.gov (United States)

    Atefi, Seyed Reza; Seoane, Fernando; Kamalian, Shervin; Rosenthal, Eric S; Lev, Michael H; Bonmassar, Giorgio

    2016-02-01

    Current diagnostic neuroimaging for detection of intracranial hemorrhage (ICH) is limited to fixed scanners requiring patient transport and extensive infrastructure support. ICH diagnosis would therefore benefit from a portable diagnostic technology, such as electrical bioimpedance (EBI). Through simulations and patient observation, the authors assessed the influence of unilateral ICH hematomas on quasisymmetric scalp potential distributions in order to establish the feasibility of EBI technology as a potential tool for early diagnosis. Finite element method (FEM) simulations and experimental left-right hemispheric scalp potential differences of healthy and damaged brains were compared with respect to the asymmetry caused by ICH lesions on quasisymmetric scalp potential distributions. In numerical simulations, this asymmetry was measured at 25 kHz and visualized on the scalp as the normalized potential difference between the healthy and ICH damaged models. Proof-of-concept simulations were extended in a pilot study of experimental scalp potential measurements recorded between 0 and 50 kHz with the authors' custom-made bioimpedance spectrometer. Mean left-right scalp potential differences recorded from the frontal, central, and parietal brain regions of ten healthy control and six patients suffering from acute/subacute ICH were compared. The observed differences were measured at the 5% level of significance using the two-sample Welch t-test. The 3D-anatomically accurate FEM simulations showed that the normalized scalp potential difference between the damaged and healthy brain models is zero everywhere on the head surface, except in the vicinity of the lesion, where it can vary up to 5%. The authors' preliminary experimental results also confirmed that the left-right scalp potential difference in patients with ICH (e.g., 64 mV) is significantly larger than in healthy subjects (e.g., 20.8 mV; P potential distributions. Pilot clinical observations with the authors

  17. A Prediction of Response of the Head and Neck of the U.S. Adult Military Population to Dynamic Impact Acceleration from Selected Dynamic Test Subjects.

    Science.gov (United States)

    1976-05-01

    It noceeawy and )Aettfi O haack mombe) Dynamic Response of Head and Neck Physical Characteristics of Head and NecK Mathematical Model Simulationj...response of these volunteers to -Gx sled acca’eratioa at 6 and 15 G’s. Procedures used for comuting the various prameter vilues w-4 coeprisons between...may be used with . mathematical modeling techniques in order to extend and project the NAMRL dynamic response results to the general adult U.S

  18. The Analysis of the Usefulness of Welded Meshes to Embankment Reinforcement

    Directory of Open Access Journals (Sweden)

    Ćwirko Marcin

    2017-09-01

    Full Text Available The aim of this paper was to find an answer to the question about the possibility of using steel welded mesh in building the retaining walls of gabion baskets. In light of the currently used gabion structure solutions, among which double-woven mesh is much more popular, the focus was put on the possibility of using welded mesh. A numerical analysis was conducted to examine the behavior of welded and woven mesh subjected to various loads and the results obtained for both types of mesh were directly compared. The maximal displacement in mesh nodes was admitted as the measurement of the system behavior (in the case of both undamaged and damaged mesh.

  19. Streaming Compression of Hexahedral Meshes

    Energy Technology Data Exchange (ETDEWEB)

    Isenburg, M; Courbet, C

    2010-02-03

    We describe a method for streaming compression of hexahedral meshes. Given an interleaved stream of vertices and hexahedral our coder incrementally compresses the mesh in the presented order. Our coder is extremely memory efficient when the input stream documents when vertices are referenced for the last time (i.e. when it contains topological finalization tags). Our coder then continuously releases and reuses data structures that no longer contribute to compressing the remainder of the stream. This means in practice that our coder has only a small fraction of the whole mesh in memory at any time. We can therefore compress very large meshes - even meshes that do not file in memory. Compared to traditional, non-streaming approaches that load the entire mesh and globally reorder it during compression, our algorithm trades a less compact compressed representation for significant gains in speed, memory, and I/O efficiency. For example, on the 456k hexahedra 'blade' mesh, our coder is twice as fast and uses 88 times less memory (only 3.1 MB) with the compressed file increasing about 3% in size. We also present the first scheme for predictive compression of properties associated with hexahedral cells.

  20. Mesh Adaptation and Shape Optimization on Unstructured Meshes Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this SBIR CRM proposes to implement the entropy adjoint method for solution adaptive mesh refinement into the Loci/CHEM unstructured flow solver. The scheme will...

  1. Nanowire mesh solar fuels generator

    Science.gov (United States)

    Yang, Peidong; Chan, Candace; Sun, Jianwei; Liu, Bin

    2016-05-24

    This disclosure provides systems, methods, and apparatus related to a nanowire mesh solar fuels generator. In one aspect, a nanowire mesh solar fuels generator includes (1) a photoanode configured to perform water oxidation and (2) a photocathode configured to perform water reduction. The photocathode is in electrical contact with the photoanode. The photoanode may include a high surface area network of photoanode nanowires. The photocathode may include a high surface area network of photocathode nanowires. In some embodiments, the nanowire mesh solar fuels generator may include an ion conductive polymer infiltrating the photoanode and the photocathode in the region where the photocathode is in electrical contact with the photoanode.

  2. Prosthetic Mesh Repair for Incarcerated Inguinal Hernia

    Directory of Open Access Journals (Sweden)

    Cihad Tatar

    2016-08-01

    Full Text Available Background: Incarcerated inguinal hernia is a commonly encountered urgent surgical condition, and tension-free repair is a well-established method for the treatment of noncomplicated cases. However, due to the risk of prosthetic material-related infections, the use of mesh in the repair of strangulated or incarcerated hernia has often been subject to debate. Recent studies have demonstrated that biomaterials represent suitable materials for performing urgent hernia repair. Certain studies recommend mesh repair only for cases where no bowel resection is required; other studies, however, recommend mesh repair for patients requiring bowel resection as well. Aim: The aim of this study was to compare the outcomes of different surgical techniques performed for strangulated hernia, and to evaluate the effect of mesh use on postoperative complications. Study Design: Retrospective cross-sectional study. Methods: This retrospective study was performed with 151 patients who had been admitted to our hospital’s emergency department to undergo surgery for a diagnosis of incarcerated inguinal hernia. The patients were divided into two groups based on the applied surgical technique. Group 1 consisted of 112 patients treated with mesh-based repair techniques, while Group 2 consisted of 39 patients treated with tissue repair techniques. Patients in Group 1 were further divided into two sub-groups: one consisting of patients undergoing bowel resection (Group 3, and the other consisting of patients not undergoing bowel resection (Group 4. Results: In Group 1, it was observed that eight (7.14% of the patients had wound infections, while two (1.78% had hematomas, four (3.57% had seromas, and one (0.89% had relapse. In Group 2, one (2.56% of the patients had a wound infection, while three (7.69% had hematomas, one (2.56% had seroma, and none had relapses. There were no statistically significant differences between the two groups with respect to wound infection

  3. Unstructured mesh methods for CFD

    Science.gov (United States)

    Peraire, J.; Morgan, K.; Peiro, J.

    1990-01-01

    Mesh generation methods for Computational Fluid Dynamics (CFD) are outlined. Geometric modeling is discussed. An advancing front method is described. Flow past a two engine Falcon aeroplane is studied. An algorithm and associated data structure called the alternating digital tree, which efficiently solves the geometric searching problem is described. The computation of an initial approximation to the steady state solution of a given poblem is described. Mesh generation for transient flows is described.

  4. GENERATION OF IRREGULAR HEXAGONAL MESHES

    Directory of Open Access Journals (Sweden)

    Vlasov Aleksandr Nikolaevich

    2012-07-01

    Decomposition is performed in a constructive way and, as option, it involves meshless representation. Further, this mapping method is used to generate the calculation mesh. In this paper, the authors analyze different cases of mapping onto simply connected and bi-connected canonical domains. They represent forward and backward mapping techniques. Their potential application for generation of nonuniform meshes within the framework of the asymptotic homogenization theory is also performed to assess and project effective characteristics of heterogeneous materials (composites.

  5. Image-driven mesh optimization

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrom, P; Turk, G

    2001-01-05

    We describe a method of improving the appearance of a low vertex count mesh in a manner that is guided by rendered images of the original, detailed mesh. This approach is motivated by the fact that greedy simplification methods often yield meshes that are poorer than what can be represented with a given number of vertices. Our approach relies on edge swaps and vertex teleports to alter the mesh connectivity, and uses the downhill simplex method to simultaneously improve vertex positions and surface attributes. Note that this is not a simplification method--the vertex count remains the same throughout the optimization. At all stages of the optimization the changes are guided by a metric that measures the differences between rendered versions of the original model and the low vertex count mesh. This method creates meshes that are geometrically faithful to the original model. Moreover, the method takes into account more subtle aspects of a model such as surface shading or whether cracks are visible between two interpenetrating parts of the model.

  6. Gendoo: functional profiling of gene and disease features using MeSH vocabulary.

    Science.gov (United States)

    Nakazato, Takeru; Bono, Hidemasa; Matsuda, Hideo; Takagi, Toshihisa

    2009-07-01

    Genome-wide data enables us to clarify the underlying molecular mechanisms of complex phenotypes. The Online Mendelian Inheritance in Man (OMIM) is a widely employed knowledge base of human genes and genetic disorders for biological researchers. However, OMIM has not been fully exploited for omics analysis because its bibliographic data structure is not suitable for computer automation. Here, we characterized diseases and genes by generating feature profiles of associated drugs, biological phenomena and anatomy with the MeSH (Medical Subject Headings) vocabulary. We obtained 1 760 054 pairs of OMIM entries and MeSH terms by utilizing the full set of MEDLINE articles. We developed a web-based application called Gendoo (gene, disease features ontology-based overview system) to visualize these profiles. By comparing feature profiles of types 1 and 2 diabetes, we clearly illustrated their differences: type 1 diabetes is an autoimmune disease (P-value = 4.55 x 10(-5)) and type 2 diabetes is related to obesity (P-value = 1.18 x 10(-15)). Gendoo and the developed feature profiles should be useful for omics analysis from molecular and clinical viewpoints. Gendoo is available at http://gendoo.dbcls.jp/.

  7. Materials characterization of explanted polypropylene hernia mesh: Patient factor correlation.

    Science.gov (United States)

    Smith, Sarah E; Cozad, Matthew J; Grant, David A; Ramshaw, Bruce J; Grant, Sheila A

    2016-02-01

    This study quantitatively assessed polypropylene (PP) hernia mesh degradation and its correlation with patient factors including body mass index, tobacco use, and diabetes status with the goal of improving hernia repair outcomes through patient-matched mesh. Thirty PP hernia mesh explants were subjected to a tissue removal process followed by assessment of their in vivo degradation using Fourier transform infrared, differential scanning calorimetry, and thermogravimetric analysis analyses. Results were then analyzed with respect to patient factors (body mass index, tobacco use, and diabetes status) to determine their influence on in vivo hernia mesh oxidation and degradation. Twenty of the explants show significant surface oxidation. Tobacco use exhibits a positive correlation with modulated differential scanning calorimetry melt temperature and exhibits significantly lower TGA decomposition temperatures than non-/past users. Chemical and thermal characterization of the explanted meshes indicate measurable degradation while in vivo regardless of the patient population; however, tobacco use is correlated with less oxidation and degradation of the polymeric mesh possibly due to a reduced inflammatory response. © The Author(s) 2015.

  8. User Manual for the PROTEUS Mesh Tools

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Micheal A. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, Emily R. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-06-01

    This report describes the various mesh tools that are provided with the PROTEUS code giving both descriptions of the input and output. In many cases the examples are provided with a regression test of the mesh tools. The most important mesh tools for any user to consider using are the MT_MeshToMesh.x and the MT_RadialLattice.x codes. The former allows the conversion between most mesh types handled by PROTEUS while the second allows the merging of multiple (assembly) meshes into a radial structured grid. Note that the mesh generation process is recursive in nature and that each input specific for a given mesh tool (such as .axial or .merge) can be used as “mesh” input for any of the mesh tools discussed in this manual.

  9. Automated Patent Categorization and Guided Patent Search using IPC as Inspired by MeSH and PubMed

    Science.gov (United States)

    2013-01-01

    Document search on PubMed, the pre-eminent database for biomedical literature, relies on the annotation of its documents with relevant terms from the Medical Subject Headings ontology (MeSH) for improving recall through query expansion. Patent documents are another important information source, though they are considerably less accessible. One option to expand patent search beyond pure keywords is the inclusion of classification information: Since every patent is assigned at least one class code, it should be possible for these assignments to be automatically used in a similar way as the MeSH annotations in PubMed. In order to develop a system for this task, it is necessary to have a good understanding of the properties of both classification systems. This report describes our comparative analysis of MeSH and the main patent classification system, the International Patent Classification (IPC). We investigate the hierarchical structures as well as the properties of the terms/classes respectively, and we compare the assignment of IPC codes to patents with the annotation of PubMed documents with MeSH terms. Our analysis shows a strong structural similarity of the hierarchies, but significant differences of terms and annotations. The low number of IPC class assignments and the lack of occurrences of class labels in patent texts imply that current patent search is severely limited. To overcome these limits, we evaluate a method for the automated assignment of additional classes to patent documents, and we propose a system for guided patent search based on the use of class co-occurrence information and external resources. PMID:23734562

  10. Automated Patent Categorization and Guided Patent Search using IPC as Inspired by MeSH and PubMed.

    Science.gov (United States)

    Eisinger, Daniel; Tsatsaronis, George; Bundschus, Markus; Wieneke, Ulrich; Schroeder, Michael

    2013-04-15

    Document search on PubMed, the pre-eminent database for biomedical literature, relies on the annotation of its documents with relevant terms from the Medical Subject Headings ontology (MeSH) for improving recall through query expansion. Patent documents are another important information source, though they are considerably less accessible. One option to expand patent search beyond pure keywords is the inclusion of classification information: Since every patent is assigned at least one class code, it should be possible for these assignments to be automatically used in a similar way as the MeSH annotations in PubMed. In order to develop a system for this task, it is necessary to have a good understanding of the properties of both classification systems. This report describes our comparative analysis of MeSH and the main patent classification system, the International Patent Classification (IPC). We investigate the hierarchical structures as well as the properties of the terms/classes respectively, and we compare the assignment of IPC codes to patents with the annotation of PubMed documents with MeSH terms.Our analysis shows a strong structural similarity of the hierarchies, but significant differences of terms and annotations. The low number of IPC class assignments and the lack of occurrences of class labels in patent texts imply that current patent search is severely limited. To overcome these limits, we evaluate a method for the automated assignment of additional classes to patent documents, and we propose a system for guided patent search based on the use of class co-occurrence information and external resources.

  11. Connectivity editing for quadrilateral meshes

    KAUST Repository

    Peng, Chihan

    2011-12-01

    We propose new connectivity editing operations for quadrilateral meshes with the unique ability to explicitly control the location, orientation, type, and number of the irregular vertices (valence not equal to four) in the mesh while preserving sharp edges. We provide theoretical analysis on what editing operations are possible and impossible and introduce three fundamental operations to move and re-orient a pair of irregular vertices. We argue that our editing operations are fundamental, because they only change the quad mesh in the smallest possible region and involve the fewest irregular vertices (i.e., two). The irregular vertex movement operations are supplemented by operations for the splitting, merging, canceling, and aligning of irregular vertices. We explain how the proposed high-level operations are realized through graph-level editing operations such as quad collapses, edge flips, and edge splits. The utility of these mesh editing operations are demonstrated by improving the connectivity of quad meshes generated from state-of-art quadrangulation techniques.

  12. Cache-oblivious mesh layouts

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sung-Eui [Univ. of North Carolina, Chapel Hill, NC (United States); Lindstrom, Peter [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pascucci, Valerio [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Manocha, Dinesh [Univ. of North Carolina, Chapel Hill, NC (United States)

    2005-07-01

    We present a novel method for computing cache-oblivious layouts of large meshes that improve the performance of interactive visualization and geometric processing algorithms. Given that the mesh is accessed in a reasonably coherent manner, we assume no particular data access patterns or cache parameters of the memory hierarchy involved in the computation. Furthermore, our formulation extends directly to computing layouts of multi-resolution and bounding volume hierarchies of large meshes. We develop a simple and practical cache-oblivious metric for estimating cache misses. Computing a coherent mesh layout is reduced to a combinatorial optimization problem. We designed and implemented an out-of-core multilevel minimization algorithm and tested its performance on unstructured meshes composed of tens to hundreds of millions of triangles. Our layouts can significantly reduce the number of cache misses. We have observed 2-20 times speedups in view-dependent rendering, collision detection, and isocontour extraction without any modification of the algorithms or runtime applications.

  13. Connectivity editing for quadrilateral meshes

    KAUST Repository

    Peng, Chihan

    2011-12-12

    We propose new connectivity editing operations for quadrilateral meshes with the unique ability to explicitly control the location, orientation, type, and number of the irregular vertices (valence not equal to four) in the mesh while preserving sharp edges. We provide theoretical analysis on what editing operations are possible and impossible and introduce three fundamental operations to move and re-orient a pair of irregular vertices. We argue that our editing operations are fundamental, because they only change the quad mesh in the smallest possible region and involve the fewest irregular vertices (i.e., two). The irregular vertex movement operations are supplemented by operations for the splitting, merging, canceling, and aligning of irregular vertices. We explain how the proposed highlevel operations are realized through graph-level editing operations such as quad collapses, edge flips, and edge splits. The utility of these mesh editing operations are demonstrated by improving the connectivity of quad meshes generated from state-of-art quadrangulation techniques. © 2011 ACM.

  14. Resting-state networks in healthy adult subjects: a comparison between a 32-element and an 8-element phased array head coil at 3.0 Tesla.

    Science.gov (United States)

    Paolini, Marco; Keeser, Daniel; Ingrisch, Michael; Werner, Natalie; Kindermann, Nicole; Reiser, Maximilian; Blautzik, Janusch

    2015-05-01

    Little research exists on the influence of a magnetic resonance imaging (MRI) head coil's channel count on measured resting-state functional connectivity. To compare a 32-element (32ch) and an 8-element (8ch) phased array head coil with respect to their potential to detect functional connectivity within resting-state networks. Twenty-six healthy adults (mean age, 21.7 years; SD, 2.1 years) underwent resting-state functional MRI at 3.0 Tesla with both coils using equal standard imaging parameters and a counterbalanced design. Independent component analysis (ICA) at different model orders and a dual regression approach were performed. Voxel-wise non-parametric statistical between-group contrasts were determined using permutation-based non-parametric inference. Phantom measurements demonstrated a generally higher image signal-to-noise ratio using the 32ch head coil. However, the results showed no significant differences between corresponding resting-state networks derived from both coils (p coil does not offer any significant advantages in detecting ICA-based functional connectivity within RSNs. © The Foundation Acta Radiologica 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Reengineering of MeSH thesauri for term selection to optimize literature retrieval and knowledge reconstruction in support of stem cell research.

    Science.gov (United States)

    Su, Yan; Andrews, James; Huang, Hong; Wang, Yue; Kong, Liangliang; Cannon, Peter; Xu, Ping

    2016-05-23

    PubMed is a widely used database for scientists to find biomedical-related literature. Due to the complexity of the selected research subject and its interdisciplinary nature, as well as the exponential growth in the number of disparate pieces of biomedical literature, it is an overwhelming challenge for scientists to define the right search strategies and quickly locate all related information. Specialized subsets and groupings of controlled vocabularies, such as Medical Subject Headings (MeSH), can enhance information retrieval in specialized domains, such as stem cell research. There is a need to develop effective search strategies and convenient solutions for knowledge organization in stem cell research. The understanding of the interrelationships between these MeSH terms also facilitates the building of knowledge organization systems in related subject fields. This study collected empirical data for MeSH-related terms from stem cell literature and developed a novel approach that uses both automation and expert-selection to create a set of terms that supports enhanced retrieval. The selected MeSH terms were reconstructed into a classified thesaurus that can guide researchers towards a successful search and knowledge organization of stem cell literature. First, 4253 MeSH terms were harvested from a sample of 5527 stem cell related research papers from the PubMed database. Next, unrelated terms were filtered out based on term frequency and specificity. Precision and recall measures were used to help identify additional valuable terms, which were mostly non-MeSH terms. The study identified 15 terms that specifically referred to stem cell research for information retrieval, which would yield a higher precision (97.7 %) and recall (94.4 %) rates in comparison to other approaches. In addition, 128 root MeSH terms were selected to conduct knowledge organization of stem cell research in categories of anatomy, disease, and others. This study presented a novel strategy

  16. Implementation of LDG method for 3D unstructured meshes

    Directory of Open Access Journals (Sweden)

    Filander A. Sequeira Chavarría

    2012-07-01

    Full Text Available This paper describes an implementation of the Local Discontinuous Galerkin method (LDG applied to elliptic problems in 3D. The implementation of the major operators is discussed. In particular the use of higher-order approximations and unstructured meshes. Efficient data structures that allow fast assembly of the linear system in the mixed formulation are described in detail. Keywords: Discontinuous finite element methods, high-order approximations, unstructured meshes, object-oriented programming. Mathematics Subject Classification: 65K05, 65N30, 65N55.

  17. Effect of 1% Inspired CO2 During Head-Down Tilt on Ocular Structures, Cerebral Blood Flow, and Visual Acuity in Healthy Human Subjects

    Science.gov (United States)

    Laurie, S. S.; Hu, X.; Lee, S. M. C.; Martin, D. S.; Phillips, T. R.; Ploutz-Snyder, R.; Smith, S. M.; Stenger, M. B.; Taibbi, G.; Zwart, S. R.; hide

    2016-01-01

    The cephalad fluid shift induced by microgravity has been hypothesized to elevate intracranial pressure (ICP) and contribute to the development of the visual impairment/intracranial pressure (VIIP) syndrome experienced by many astronauts during and after long-duration space flight. In addition, elevated ambient partial pressure of carbon dioxide (PCO2) on the International Space Station (ISS) has also been hypothesized to contribute to the development of VIIP. We seek to determine if an acute, mild CO2 exposure, similar to that occurring on the ISS, combined with the cephalad fluid shift induced by head-down tilt will induce ophthalmic and ICP changes consistent with the VIIP syndrome.

  18. Experimental study of the characteristics of a novel mesh suture.

    Science.gov (United States)

    Dumanian, G A; Tulaimat, A; Dumanian, Z P

    2015-09-01

    The failure of sutures to maintain tissue in apposition is well characterized in hernia repairs. A mesh suture designed to facilitate tissue integration into and around the filaments may improve tissue hold and decrease suture pull-through. In vitro, the sutures were compared for resistance to pull-through in ballistics gel. In vivo, closure of midline laparotomy incisions was done with both sutures in 11 female pigs. Tissue segments were subsequently subjected to mechanical and histological testing. The mesh suture had tensile characteristics nearly identical to those of 0-polypropylene suture. Mesh suture demonstrated greater resistance to pull-through than standard suture (mean(s.d.) 4.27(0.42) versus 2.23(0.48) N; P suture (320(57) versus 160(56) N; P suture. Histological examination at 8 and 90 days showed complete tissue integration of the mesh suture. The novel mesh suture structure increased the strength of early wound healing in an experimental model. Surgical relevance Traditional sutures have the significant drawback of cutting and pulling through tissues in high-tension closures. A new mesh suture design with a flexible macroporous outer wall and a hollow core allows the tissues to grow into the suture, improving early wound strength and decreasing suture pull-through. This technology may dramatically increase the reliability of high-tension closures, thereby preventing incisional hernia after laparotomy. As suture pull-through is a problem relevant to all surgical disciplines, numerous additional indications are envisioned with mesh suture formulations of different physical properties and materials. © 2015 The Authors. BJS published by John Wiley & Sons Ltd on behalf of BJS Society Ltd.

  19. Hierarchical multi-resolution mesh networks for brain decoding.

    Science.gov (United States)

    Onal Ertugrul, Itir; Ozay, Mete; Yarman Vural, Fatos T

    2017-10-04

    Human brain is supposed to process information in multiple frequency bands. Therefore, we can extract diverse information from functional Magnetic Resonance Imaging (fMRI) data by processing it at multiple resolutions. We propose a framework, called Hierarchical Multi-resolution Mesh Networks (HMMNs), which establishes a set of brain networks at multiple resolutions of fMRI signal to represent the underlying cognitive process. Our framework, first, decomposes the fMRI signal into various frequency subbands using wavelet transform. Then, a brain network is formed at each subband by ensembling a set of local meshes. Arc weights of each local mesh are estimated by ridge regression. Finally, adjacency matrices of mesh networks obtained at different subbands are used to train classifiers in an ensemble learning architecture, called fuzzy stacked generalization (FSG). Our decoding performances on Human Connectome Project task-fMRI dataset reflect that HMMNs can successfully discriminate tasks with 99% accuracy, across 808 subjects. Diversity of information embedded in mesh networks of multiple subbands enables the ensemble of classifiers to collaborate with each other for brain decoding. The suggested HMMNs decode the cognitive tasks better than a single classifier applied to any subband. Also mesh networks have a better representation power compared to pairwise correlations or average voxel time series. Moreover, fusion of diverse information using FSG outperforms fusion with majority voting. We conclude that, fMRI data, recorded during a cognitive task, provide diverse information in multi-resolution mesh networks. Our framework fuses this complementary information and boosts the brain decoding performances obtained at individual subbands.

  20. Hybrid Mesh for Nasal Airflow Studies

    Directory of Open Access Journals (Sweden)

    Mohammed Zubair

    2013-01-01

    Full Text Available The accuracy of the numerical result is closely related to mesh density as well as its distribution. Mesh plays a very significant role in the outcome of numerical simulation. Many nasal airflow studies have employed unstructured mesh and more recently hybrid mesh scheme has been utilized considering the complexity of anatomical architecture. The objective of this study is to compare the results of hybrid mesh with unstructured mesh and study its effect on the flow parameters inside the nasal cavity. A three-dimensional nasal cavity model is reconstructed based on computed tomographic images of a healthy Malaysian adult nose. Navier-Stokes equation for steady airflow is solved numerically to examine inspiratory nasal flow. The pressure drop obtained using the unstructured computational grid is about 22.6 Pa for a flow rate of 20 L/min, whereas the hybrid mesh resulted in 17.8 Pa for the same flow rate. The maximum velocity obtained at the nasal valve using unstructured grid is 4.18 m/s and that with hybrid mesh is around 4.76 m/s. Hybrid mesh reported lower grid convergence index (GCI than the unstructured mesh. Significant differences between unstructured mesh and hybrid mesh are determined highlighting the usefulness of hybrid mesh for nasal airflow studies.

  1. Mesh Sutured Repairs of Abdominal Wall Defects

    National Research Council Canada - National Science Library

    Lanier, Steven T; Dumanian, Gregory A; Jordan, Sumanas W; Miller, Kyle R; Ali, Nada A; Stock, Stuart R

    2016-01-01

    BACKGROUND:A new closure technique is introduced, which uses strips of macroporous polypropylene mesh as a suture for closure of abdominal wall defects due to failures of standard sutures and difficulties with planar meshes...

  2. 6th International Meshing Roundtable '97

    Energy Technology Data Exchange (ETDEWEB)

    White, D.

    1997-09-01

    The goal of the 6th International Meshing Roundtable is to bring together researchers and developers from industry, academia, and government labs in a stimulating, open environment for the exchange of technical information related to the meshing process. In the pas~ the Roundtable has enjoyed significant participation born each of these groups from a wide variety of countries. The Roundtable will consist of technical presentations from contributed papers and abstracts, two invited speakers, and two invited panels of experts discussing topics related to the development and use of automatic mesh generation tools. In addition, this year we will feature a "Bring Your Best Mesh" competition and poster session to encourage discussion and participation from a wide variety of mesh generation tool users. The schedule and evening social events are designed to provide numerous opportunities for informal dialog. A proceedings will be published by Sandia National Laboratories and distributed at the Roundtable. In addition, papers of exceptionally high quaIity will be submitted to a special issue of the International Journal of Computational Geometry and Applications. Papers and one page abstracts were sought that present original results on the meshing process. Potential topics include but are got limited to: Unstructured triangular and tetrahedral mesh generation Unstructured quadrilateral and hexahedral mesh generation Automated blocking and structured mesh generation Mixed element meshing Surface mesh generation Geometry decomposition and clean-up techniques Geometry modification techniques related to meshing Adaptive mesh refinement and mesh quality control Mesh visualization Special purpose meshing algorithms for particular applications Theoretical or novel ideas with practical potential Technical presentations from industrial researchers.

  3. Feature engineering for MEDLINE citation categorization with MeSH.

    Science.gov (United States)

    Jimeno Yepes, Antonio Jose; Plaza, Laura; Carrillo-de-Albornoz, Jorge; Mork, James G; Aronson, Alan R

    2015-04-08

    Research in biomedical text categorization has mostly used the bag-of-words representation. Other more sophisticated representations of text based on syntactic, semantic and argumentative properties have been less studied. In this paper, we evaluate the impact of different text representations of biomedical texts as features for reproducing the MeSH annotations of some of the most frequent MeSH headings. In addition to unigrams and bigrams, these features include noun phrases, citation meta-data, citation structure, and semantic annotation of the citations. Traditional features like unigrams and bigrams exhibit strong performance compared to other feature sets. Little or no improvement is obtained when using meta-data or citation structure. Noun phrases are too sparse and thus have lower performance compared to more traditional features. Conceptual annotation of the texts by MetaMap shows similar performance compared to unigrams, but adding concepts from the UMLS taxonomy does not improve the performance of using only mapped concepts. The combination of all the features performs largely better than any individual feature set considered. In addition, this combination improves the performance of a state-of-the-art MeSH indexer. Concerning the machine learning algorithms, we find that those that are more resilient to class imbalance largely obtain better performance. We conclude that even though traditional features such as unigrams and bigrams have strong performance compared to other features, it is possible to combine them to effectively improve the performance of the bag-of-words representation. We have also found that the combination of the learning algorithm and feature sets has an influence in the overall performance of the system. Moreover, using learning algorithms resilient to class imbalance largely improves performance. However, when using a large set of features, consideration needs to be taken with algorithms due to the risk of over-fitting. Specific

  4. User Manual for the PROTEUS Mesh Tools

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Micheal A. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, Emily R [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-09-19

    PROTEUS is built around a finite element representation of the geometry for visualization. In addition, the PROTEUS-SN solver was built to solve the even-parity transport equation on a finite element mesh provided as input. Similarly, PROTEUS-MOC and PROTEUS-NEMO were built to apply the method of characteristics on unstructured finite element meshes. Given the complexity of real world problems, experience has shown that using commercial mesh generator to create rather simple input geometries is overly complex and slow. As a consequence, significant effort has been put into place to create multiple codes that help assist in the mesh generation and manipulation. There are three input means to create a mesh in PROTEUS: UFMESH, GRID, and NEMESH. At present, the UFMESH is a simple way to generate two-dimensional Cartesian and hexagonal fuel assembly geometries. The UFmesh input allows for simple assembly mesh generation while the GRID input allows the generation of Cartesian, hexagonal, and regular triangular structured grid geometry options. The NEMESH is a way for the user to create their own mesh or convert another mesh file format into a PROTEUS input format. Given that one has an input mesh format acceptable for PROTEUS, we have constructed several tools which allow further mesh and geometry construction (i.e. mesh extrusion and merging). This report describes the various mesh tools that are provided with the PROTEUS code giving both descriptions of the input and output. In many cases the examples are provided with a regression test of the mesh tools. The most important mesh tools for any user to consider using are the MT_MeshToMesh.x and the MT_RadialLattice.x codes. The former allows the conversion between most mesh types handled by PROTEUS while the second allows the merging of multiple (assembly) meshes into a radial structured grid. Note that the mesh generation process is recursive in nature and that each input specific for a given mesh tool (such as .axial

  5. MeSHer: identifying biological concepts in microarray assays based on PubMed references and MeSH terms.

    Science.gov (United States)

    Djebbari, Amira; Karamycheva, Svetlana; Howe, Eleanor; Quackenbush, John

    2005-08-01

    MeSHer uses a simple statistical approach to identify biological concepts in the form of Medical Subject Headings (MeSH terms) obtained from the PubMed database that are significantly overrepresented within the identified gene set relative to those associated with the overall collection of genes on the underlying DNA microarray platform. As a demonstration, we apply this approach to gene lists acquired from a published study of the effects of angiotensin II (Ang II) treatment on cardiac gene expression and demonstrate that this approach can aid in the interpretation of the resulting 'significant' gene set. The software is available at http://www.tm4.org. Results from the analysis of significant genes from the published Ang II study.

  6. Mesh materials and hernia repair

    Science.gov (United States)

    Elango, Santhini; Perumalsamy, Sakthivel; Ramachandran, Krishnakumar; Vadodaria, Ketankumar

    2017-01-01

    Hernia incidence has been observed since ancient time. Advancement in the medical textile industry came up with the variety of mesh materials to repair hernia, but none of them are without complications including recurrence of hernia. Therefore individuals once developed with the hernia could not lead a healthy and comfortable life. This drawn attention of surgeons, patients, researchers and industry to know the exact mechanism behind its development, complications and recurrence. Recent investigations highlighted the role of genetic factors and connective tissue disorders being the reason for the development of hernia apart from the abnormal pressure that is known to develop during other disease conditions. This review discusses different mesh materials, their advantages and disadvantages and their biological response after its implantation. PMID:28840830

  7. Cam deformity and the omega angle, a novel quantitative measurement of femoral head-neck morphology: a 3D CT gender analysis in asymptomatic subjects

    Energy Technology Data Exchange (ETDEWEB)

    Mascarenhas, Vasco V.; Gaspar, Augusto [Hospital da Luz, MSK imaging Unit (UIME), Imaging Center, Lisbon (Portugal); Rego, Paulo [Hospital da Luz, Department of Orthopaedic Surgery, Lisbon (Portugal); Dantas, Pedro [Hospital CUF Descobertas, Lisbon (Portugal); Soldado, Francisco [Universitat de Barcelona, Hospital Sant Joan de Deu, Barcelona (Spain); Consciencia, Jose G. [NOVA Medical School, Lisbon (Portugal)

    2017-05-15

    Our objectives were to use 3D computed tomography (CT) to define head-neck morphologic gender-specific and normative parameters in asymptomatic individuals and use the omega angle (Ω ) to provide quantification data on the location and radial extension of a cam deformity. We prospectively included 350 individuals and evaluated 188 asymptomatic hips that underwent semiautomated CT analysis. Different thresholds of alpha angle (α ) were considered in order to analyze cam morphology and determine Ω . We calculated overall and gender-specific parameters for imaging signs of cam morphology (Ω and circumferential α ). The 95 % reference interval limits were beyond abnormal thresholds found in the literature for cam morphology. Specifically, α at 3/1 oclock were 46.9 /60.8 overall, 51.8 /65.4 for men and 45.7 /55.3 for women. Cam prevalence, magnitude, location, and epicenter were significantly gender different. Increasing α correlated with higher Ω , meaning that higher angles correspond to larger cam deformities. Hip morphometry measurements in this cohort of asymptomatic individuals extended beyond current thresholds used for the clinical diagnosis of cam deformity, and α was found to vary both by gender and measurement location. These results suggest that α measurement is insufficient for the diagnosis of cam deformity. Enhanced morphometric evaluation, including 3D imaging and Ω , may enable a more accurate diagnosis. (orig.)

  8. Translating MeSH concepts.

    Science.gov (United States)

    Soualmia, Lina F; Letord, Catherine; Merabti, Tayeb; Griffon, Nicolas; Manel, Jacques; Darmoni, Stéfan J

    2013-01-01

    The concept-oriented structure of the MeSH® thesaurus is not yet in common use. Nevertheless, it has been shown that a concept-based querying of PubMed may be of interest. To take full advantage of the concept-oriented structure of MeSH in the information retrieval tool associated with the CISMeF catalogue, it was necessary to translate such concepts into French.

  9. Histologic and biomechanical evaluation of a novel macroporous polytetrafluoroethylene knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral incisional hernia repair

    Science.gov (United States)

    Melman, L.; Jenkins, E. D.; Hamilton, N. A.; Bender, L. C.; Brodt, M. D.; Deeken, C. R.; Greco, S. C.; Frisella, M. M.

    2013-01-01

    Purpose To evaluate the biocompatibility of heavyweight polypropylene (HWPP), lightweight polypropylene (LWPP), and monofilament knit polytetrafluoroethylene (mkPTFE) mesh by comparing biomechanics and histologic response at 1, 3, and 5 months in a porcine model of incisional hernia repair. Methods Bilateral full-thickness abdominal wall defects measuring 4 cm in length were created in 27 Yucatan minipigs. Twenty-one days after hernia creation, animals underwent bilateral preperitoneal ventral hernia repair with 8 × 10 cm pieces of mesh. Repairs were randomized to Bard®Mesh (HWPP, Bard/Davol, http://www.davol.com), ULTRAPRO® (LWPP, Ethicon, http://www.ethicon.com), and GORE®INFINIT Mesh (mkPTFE, Gore & Associates, http://www.gore.com). Nine animals were sacrificed at each timepoint (1, 3, and 5 months). At harvest, a 3 × 4 cm sample of mesh and incorporated tissue was taken from the center of the implant site and subjected to uniaxial tensile testing at a rate of 0.42 mm/s. The maximum force (N) and tensile strength (N/cm) were measured with a tensiometer, and stiffness (N/mm) was calculated from the slope of the force-versus-displacement curve. Adjacent sections of tissue were stained with hematoxylin and eosin (H&E) and analyzed for inflammation, fibrosis, and tissue ingrowth. Data are reported as mean ± SEM. Statistical significance (P 0.05 for all comparisons). However, for each mesh type, the maximum strength at 5 months was significantly lower than that at 1 month (P 0.05 for all comparisons). No significant differences with regard to inflammation, fibrosis, or tissue ingrowth were detected between mesh types at any time point (P > 0.09 for all comparisons). However, over time, inflammation decreased significantly for all mesh types (P 0.09). Conclusions The maximum tensile strength of mesh in the abdominal wall decreased over time for HWPP, LWPP, and mkPTFE mesh materials alike. This trend may actually reflect inability to adequately grip specimens at

  10. Adaptive mesh generation for image registration and segmentation

    DEFF Research Database (Denmark)

    Fogtmann, Mads; Larsen, Rasmus

    2013-01-01

    This paper deals with the problem of generating quality tetrahedral meshes for image registration. From an initial coarse mesh the approach matches the mesh to the image volume by combining red-green subdivision and mesh evolution through mesh-to-image matching regularized with a mesh quality...

  11. Enthesitis in patients with psoriatic arthritis, axial spondyloarthritis and healthy subjects assessed by ‘head-to-toe’ whole-body MRI and clinical examination

    DEFF Research Database (Denmark)

    Poggenborg, René Panduro; Eshed, Iris; Østergaard, Mikkel

    2015-01-01

    OBJECTIVES: To investigate the ability of whole-body MRI (WBMRI) to detect axial and peripheral enthesitis in patients with psoriatic arthritis (PsA) and axial spondyloarthritis (axSpA), and in healthy subjects (HS). Furthermore, to develop MRI enthesitis indices based on WBMRI and validate...... and patient global (ρ=0.29-0.31, pimaging modality for evaluation of enthesitis in patients with PsA and axSpA, but requires further investigation before clinical use....

  12. Characterizing the Vertical Distribution of Hydraulic Conductivity Using the Multilevel Slug Test Subject to Skin Effects: Comparison of the Uniform-head and Uniform-flux Wellbore Conditions

    Science.gov (United States)

    wei-Chiang, C.; Chen, C. S.

    2016-12-01

    The multilevel slug test (MLST) is an in-well technique in characterizing the vertical distribution of hydraulic conductivity K(z) in granular or fractured formations. In modeling MLST, the well screen is either simulated as a uniform-flux (UF) or a uniform head (UH) condition. This study investigates the impact of the skin effect, positive or negative, on the UH and UF models. The positive skin effect, as associated with a reduced hydraulic conductivity surrounding the well due to drilling mud invasion, is taken into account by making use of a skin factor, Sk.The negative skin effect, as associated with an increased hydraulic conductivity due to overdeveloping of the well, is modeled by using an effective well radius, re, which is greater than or equal to the well radius, rw. The UF and UH models are compared using different values of Sk and re for a variety of the partial penetration ratio of screen length to aquifer thickness, φ, the vertical anisotropy ratio of hydraulic conductivity, κ, and the aspect ratio of rw to the screen length, α. It is found that (1) the two models yield results of negligible difference when the well fully penetrates the aquifer (i.e., φ=1) regardless of the values of α,κ, Sk or re, (2) the two models yield essentially the same results for negative skin for all α and κ, (3) the difference between the two models decreases as Sk gets larger, regardless of the values of α, φ, or κ, yet it becomes negligible for Sk is greater than unity, and (4) when the skin effect is absent, the maximum difference between the two models is within 3-5%. As a result, it is suggested the UF model be used since it is mathematically easier to solve than the UH model, with or without skin effects.

  13. Determination of an Initial Mesh Density for Finite Element Computations via Data Mining

    Energy Technology Data Exchange (ETDEWEB)

    Kanapady, R; Bathina, S K; Tamma, K K; Kamath, C; Kumar, V

    2001-07-23

    Numerical analysis software packages which employ a coarse first mesh or an inadequate initial mesh need to undergo a cumbersome and time consuming mesh refinement studies to obtain solutions with acceptable accuracy. Hence, it is critical for numerical methods such as finite element analysis to be able to determine a good initial mesh density for the subsequent finite element computations or as an input to a subsequent adaptive mesh generator. This paper explores the use of data mining techniques for obtaining an initial approximate finite element density that avoids significant trial and error to start finite element computations. As an illustration of proof of concept, a square plate which is simply supported at its edges and is subjected to a concentrated load is employed for the test case. Although simplistic, the present study provides insight into addressing the above considerations.

  14. Outcomes and Characteristics of Patients Undergoing Surgical Management for Mesh Related Complications.

    Science.gov (United States)

    Mazloomdoost, Donna; Pauls, Rachel N; Kleeman, Steven D; Crisp, Catrina C

    2017-06-27

    The aims of this study were to describe the characteristics of women presenting with mesh-related complications and evaluate postoperative quality of life, sexual functioning, and patient-perceived outcomes. This institutional review board-approved study included a retrospective chart review and a cross-sectional follow-up with validated questionnaires. Demographics and medical histories were collected from charts of women treated for mesh-related complaints between 2010 and 2014. Subjects completed follow-up validated questionnaires regarding health, sexual functioning, postoperative symptom improvement/severity, satisfaction, and regret with the decision to pursue treatment. Ninety-three charts were analyzed. Mean subject age was 55 years, median body mass index was 28.7 kg/m, and median time from mesh placement to presentation was 2.7 years. Forty-nine had midurethral sling mesh only, 30 had prolapse-related mesh, and 14 had both. Forty-two subjects (48.9%) had mesh exposures, 19 involving prolapse-related mesh (52.4% transvaginal and 47.4% sacrocolpopexy). Surgical revisions were most often for exposure and pain. Seventy-five women were reached for follow-up; 71 agreed to participate, 53 (75%) returned the questionnaires. Thirty had sling revision, 22 had prolapse mesh revision, and 1 had both. Questionnaire results revealed no changes in health or sexual function after treatment. Postoperatively, subjects reported symptom improvement, low symptom severity, as well as high satisfaction and low regret with the decision to pursue surgical intervention. Women with mesh complications presented 2 years after initial placement, most often complaining of exposure or pain/dyspareunia. Although no changes in health or sexual functioning were noted postoperatively, participants reported symptom improvement after revision and satisfaction with the decision to pursue treatment.

  15. Synthetic Versus Biological Mesh-Related Erosion After Laparoscopic Ventral Mesh Rectopexy: A Systematic Review.

    Science.gov (United States)

    Balla, Andrea; Quaresima, Silvia; Smolarek, Sebastian; Shalaby, Mostafa; Missori, Giulia; Sileri, Pierpaolo

    2017-04-01

    This review reports the incidence of mesh-related erosion after ventral mesh rectopexy to determine whether any difference exists in the erosion rate between synthetic and biological mesh. A systematic search of the MEDLINE and the Ovid databases was conducted to identify suitable articles published between 2004 and 2015. The search strategy capture terms were laparoscopic ventral mesh rectopexy, laparoscopic anterior rectopexy, robotic ventral rectopexy, and robotic anterior rectopexy. Eight studies (3,956 patients) were included in this review. Of those patients, 3,517 patients underwent laparoscopic ventral rectopexy (LVR) using synthetic mesh and 439 using biological mesh. Sixty-six erosions were observed with synthetic mesh (26 rectal, 32 vaginal, 8 recto-vaginal fistulae) and one (perineal erosion) with biological mesh. The synthetic and the biological mesh-related erosion rates were 1.87% and 0.22%, respectively. The time between rectopexy and diagnosis of mesh erosion ranged from 1.7 to 124 months. No mesh-related mortalities were reported. The incidence of mesh-related erosion after LVR is low and is more common after the placement of synthetic mesh. The use of biological mesh for LVR seems to be a safer option; however, large, multicenter, randomized, control trials with long follow-ups are required if a definitive answer is to be obtained.

  16. Effects of the polypropylene mesh implanted through inguinotomy in the spermatic funiculus, epididium and testis of dogs

    Directory of Open Access Journals (Sweden)

    Goldenberg Alberto

    2005-01-01

    Full Text Available PURPOSE: To investigate the effects of polypropylene mesh, implanted by inguinotomy, in the spermatic funiculus, epididium and testis of dogs. METHODS: Eighteen dogs were considered (12-23 Kg, separated in three groups. Group A (n=7: left side (with mesh versus right side (without mesh; Group B (n=7: left side (without mesh versus right side (with mesh and Group C (n=4: without any surgical manipulation (control group. After being observed for 60 days, the animals were subjected to bilateral removal of the spermatic funiculus, epididium and testis that were submitted to histological analysis. During the re-operation, a macroscopic evaluation was performed. RESULTS: On the mesh side, we noted 100% of mesh adherence to the posterior wall of the inguinal canal, as well as the adherence of the spermatic funiculus to the mesh. A congestion of the pampiniform plexus was noted in three animals. Chronic inflammation reaction and foreign body reaction in the spermatic funiculus was observed in 100% of the animals. On the side that did not carry a mesh, chronic inflammatory reaction was observed in 71% of the animals. All the animals presented chronic inflammatory reaction in the deferent duct in the mesh side and in eleven animals in the side without the mesh. These alterations were not found in Group C. There was a considerable statistical reduction in the average difference of the diameter of the lumen of the deferent duct in the mesh side. In the epididium and testis, macro and microscopic alterations were not significant, although one animal presented a marked reduction of spermatogenesis on the mesh side. CONCLUSION: The polypropylene mesh, when in contact with the spermatic funiculus of dogs, causes a more intense chronic inflammatory reaction and a significant reduction in the diameter of the lumen of the deferent duct.

  17. Hip Joint Replacement Using Monofilament Polypropylene Surgical Mesh: An Animal Model

    Directory of Open Access Journals (Sweden)

    Jacek Białecki

    2014-01-01

    Full Text Available Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS, triple pelvic osteotomy (TPO, total hip replacement (THR, and femoral head and neck resection (FHNE. The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform.

  18. Hip Joint Replacement Using Monofilament Polypropylene Surgical Mesh: An Animal Model

    Science.gov (United States)

    Białecki, Jacek; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof

    2014-01-01

    Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform. PMID:24987672

  19. Laparoscopic appendicectomy for suspected mesh-induced appendicitis after laparoscopic transabdominal preperitoneal polypropylene mesh inguinal herniorraphy

    Directory of Open Access Journals (Sweden)

    Jennings Jason

    2010-01-01

    Full Text Available Laparoscopic inguinal herniorraphy via a transabdominal preperitoneal (TAPP approach using Polypropylene Mesh (Mesh and staples is an accepted technique. Mesh induces a localised inflammatory response that may extend to, and involve, adjacent abdominal and pelvic viscera such as the appendix. We present an interesting case of suspected Mesh-induced appendicitis treated successfully with laparoscopic appendicectomy, without Mesh removal, in an elderly gentleman who presented with symptoms and signs of acute appendicitis 18 months after laparoscopic inguinal hernia repair. Possible mechanisms for Mesh-induced appendicitis are briefly discussed.

  20. Head Injuries

    Science.gov (United States)

    ... ATV) Safety Balance Disorders Knowing Your Child's Medical History First Aid: Falls First Aid: Head Injuries Preventing Children's Sports Injuries Getting Help: Know the Numbers Concussions Stay ...

  1. Evidence to justify retention of transvaginal mesh: comparison between laparoscopic sacral colpopexy and transvaginal Elevate™ mesh.

    Science.gov (United States)

    To, Valérie; Hengrasmee, Pattaya; Lam, Alan; Luscombe, Georgina; Lawless, Anna; Lam, Justin

    2017-12-01

    To determine if laparoscopic sacral colpopexy (LSC) offers better apical support with a lower exposure rate than transvaginal mesh surgery with Elevate™. This was a retrospective cohort study comparing patients with apical prolapse (POP-Q point C ≥ -1) who underwent Elevate™ mesh repair (n = 146) with patients who underwent laparoscopic sacral colpopexy (n = 267). The sacral colpopexy group had a mean age of 59 years and a BMI of 25.7. Patients in the Elevate™ group were older, with a mean age of 63 and a BMI of 26.3. Most of the patients of both groups presented with pelvic organ prolapse stage III (LSC 73.8% and Elevate™ 87.0%) and their mean POP-Q point C were not significantly different (LSC 1.4 vs Elevate™ 1.2 cm). Operative time was longer in the LSC group (113 vs 91 min, p to 2.10, p = 0.21). One-year objective cure rate, defined as no descent beyond the hymen, was 97.0% in the LSC group and 96.6% in the Elevate™ group (p = .81). The overall recurrence (objective, subjective recurrence or reoperation) was also not different between the groups (LSC 4.5% vs Elevate 4.8%, p = 0.89). Transvaginal Elevate™ mesh delivers comparable apical support with a low exposure rate similar to that of laparoscopic sacral colpopexy.

  2. Bluetooth Low Energy Mesh Networks: A Survey.

    Science.gov (United States)

    Darroudi, Seyed Mahdi; Gomez, Carles

    2017-06-22

    Bluetooth Low Energy (BLE) has gained significant momentum. However, the original design of BLE focused on star topology networking, which limits network coverage range and precludes end-to-end path diversity. In contrast, other competing technologies overcome such constraints by supporting the mesh network topology. For these reasons, academia, industry, and standards development organizations have been designing solutions to enable BLE mesh networks. Nevertheless, the literature lacks a consolidated view on this emerging area. This paper comprehensively surveys state of the art BLE mesh networking. We first provide a taxonomy of BLE mesh network solutions. We then review the solutions, describing the variety of approaches that leverage existing BLE functionality to enable BLE mesh networks. We identify crucial aspects of BLE mesh network solutions and discuss their advantages and drawbacks. Finally, we highlight currently open issues.

  3. Unstructured Polyhedral Mesh Thermal Radiation Diffusion

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, T.S.; Zika, M.R.; Madsen, N.K.

    2000-07-27

    Unstructured mesh particle transport and diffusion methods are gaining wider acceptance as mesh generation, scientific visualization and linear solvers improve. This paper describes an algorithm that is currently being used in the KULL code at Lawrence Livermore National Laboratory to solve the radiative transfer equations. The algorithm employs a point-centered diffusion discretization on arbitrary polyhedral meshes in 3D. We present the results of a few test problems to illustrate the capabilities of the radiation diffusion module.

  4. Steps Towards Automated Robust RANS Meshing

    OpenAIRE

    Tomac, Maximilian; Eller, David

    2013-01-01

    The creation of high-quality discretizations for use in viscous flow simulations remains a challenging task. Even with modern software tools and substantial human effort, the application of state-of-the-art mesh generation algorithms in the presence of geometric features such as concave corners may still result in inadequate local mesh configurations, which can severely affect the resolution of important flow features. To address such issues, mesh generation tools for hybrid unstructured grid...

  5. Conformal refinement of unstructured quadrilateral meshes

    Energy Technology Data Exchange (ETDEWEB)

    Garmella, Rao [Los Alamos National Laboratory

    2009-01-01

    We present a multilevel adaptive refinement technique for unstructured quadrilateral meshes in which the mesh is kept conformal at all times. This means that the refined mesh, like the original, is formed of only quadrilateral elements that intersect strictly along edges or at vertices, i.e., vertices of one quadrilateral element do not lie in an edge of another quadrilateral. Elements are refined using templates based on 1:3 refinement of edges. We demonstrate that by careful design of the refinement and coarsening strategy, we can maintain high quality elements in the refined mesh. We demonstrate the method on a number of examples with dynamically changing refinement regions.

  6. Converting skeletal structures to quad dominant meshes

    DEFF Research Database (Denmark)

    Bærentzen, Jakob Andreas; Misztal, Marek Krzysztof; Welnicka, Katarzyna

    2012-01-01

    We propose the Skeleton to Quad-dominant polygonal Mesh algorithm (SQM), which converts skeletal structures to meshes composed entirely of polar and annular regions. Both types of regions have a regular structure where all faces are quads except for a single ring of triangles at the center of each...... polar region. The algorithm produces high quality meshes which contain irregular vertices only at the poles or where several regions join. It is trivial to produce a stripe parametrization for the output meshes which also lend themselves well to polar subdivision. After an initial description of SQM, we...

  7. Automatic tetrahedral mesh generation for impact computations

    Science.gov (United States)

    Kraus, E. I.; Shabalin, I. I.; Shabalin, T. I.

    2017-10-01

    Explicit time integration schemes for dynamic processes simulation in solids put strong demands on the meshes. A technique for mesh generation in complicated three-dimensional bodies is developed. It consists of immersion of the body in a domain with a high quality mesh. Then the knots lying outside of the body are removed and the knot distribution near the boundary is regularized by the bubble packing method. Local transformations of tetrahedra groups allow to improve mesh quality. Parallel execution of the algorithm is discussed.

  8. Transrectal Mesh Erosion Requiring Bowel Resection.

    Science.gov (United States)

    Kemp, Marta Maria; Slim, Karem; Rabischong, Benoît; Bourdel, Nicolas; Canis, Michel; Botchorishvili, Revaz

    To report a case of a transrectal mesh erosion as complication of laparoscopic promontofixation with mesh repair, necessitating bowel resection and subsequent surgical interventions. Sacrocolpopexy has become a standard procedure for vaginal vault prolapse [1], and the laparoscopic approach has gained popularity owing to more rapid recovery and less morbidity [2,3]. Mesh erosion is a well-known complication of surgical treatment for prolapse as reported in several negative evaluations, including a report from the US Food and Drug Administration in 2011 [4]. Mesh complications are more common after surgeries via the vaginal approach [5]; nonetheless, the incidence of vaginal mesh erosion after laparoscopic procedures is as high as 9% [6]. The incidence of transrectal mesh exposure after laparoscopic ventral rectopexy is roughly 1% [7]. The diagnosis may be delayed because of its rarity and variable presentation. In addition, polyester meshes, such as the mesh used in this case, carry a higher risk of exposure [8]. A 57-year-old woman experiencing genital prolapse, with the cervix classified as +3 according to the Pelvic Organ Prolapse Quantification system, underwent laparoscopic standard sacrocolpopexy using polyester mesh. Subtotal hysterectomy and bilateral adnexectomy were performed concomitantly. A 3-year follow-up consultation demonstrated no signs or symptoms of erosion of any type. At 7 years after the surgery, however, the patient presented with rectal discharge, diagnosed as infectious rectocolitis with the isolation of Clostridium difficile. She underwent a total of 5 repair surgeries in a period of 4 months, including transrectal resection of exposed mesh, laparoscopic ablation of mesh with digestive resection, exploratory laparoscopy with abscess drainage, and exploratory laparoscopy with ablation of residual mesh and transverse colostomy. She recovered well after the last intervention, exhibiting no signs of vaginal or rectal fistula and no recurrence

  9. Meshes optimized for discrete exterior calculus (DEC).

    Energy Technology Data Exchange (ETDEWEB)

    Mousley, Sarah C. [Univ. of Illinois, Urbana-Champaign, IL (United States); Deakin, Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Knupp, Patrick [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mitchell, Scott A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-12-01

    We study the optimization of an energy function used by the meshing community to measure and improve mesh quality. This energy is non-traditional because it is dependent on both the primal triangulation and its dual Voronoi (power) diagram. The energy is a measure of the mesh's quality for usage in Discrete Exterior Calculus (DEC), a method for numerically solving PDEs. In DEC, the PDE domain is triangulated and this mesh is used to obtain discrete approximations of the continuous operators in the PDE. The energy of a mesh gives an upper bound on the error of the discrete diagonal approximation of the Hodge star operator. In practice, one begins with an initial mesh and then makes adjustments to produce a mesh of lower energy. However, we have discovered several shortcomings in directly optimizing this energy, e.g. its non-convexity, and we show that the search for an optimized mesh may lead to mesh inversion (malformed triangles). We propose a new energy function to address some of these issues.

  10. Laparoscopic removal of intravesical mesh following pelvic organ prolapse mesh surgery.

    Science.gov (United States)

    Maher, Christopher; Feiner, Benjamin

    2011-12-01

    With the increasing popularity of mesh in prolapse surgery, complications such as intravesical mesh will arise more frequently. In three cases intravesical mesh was identified in the trigone of the bladder following laparoscopic mesh hysteropexy, open sacral colpopexy, and transvaginal mesh repair and presented 9 months to 7 years later with a variety of symptoms including recurrent urinary tract infections, suprapubic pain, and constant urinary leakage. Each underwent uncomplicated laparoscopic transvesical removal of intravesical mesh. Intravesical mesh can present years following index prolapse surgery and can develop despite the bladder integrity being documented as being intact at the initial surgery. The laparoscopic approach to the removal of intravesical mesh is feasible, minimally invasive, and a precise approach to this challenging complication.

  11. Tensile Behaviour of Welded Wire Mesh and Hexagonal Metal Mesh for Ferrocement Application

    Science.gov (United States)

    Tanawade, A. G.; Modhera, C. D.

    2017-08-01

    Tension tests were conducted on welded mesh and hexagonal Metal mesh. Welded Mesh is available in the market in different sizes. The two types are analysed viz. Ø 2.3 mm and Ø 2.7 mm welded mesh, having opening size 31.75 mm × 31.75 mm and 25.4 mm × 25.4 mm respectively. Tensile strength test was performed on samples of welded mesh in three different orientations namely 0°, 30° and 45° degrees with the loading axis and hexagonal Metal mesh of Ø 0.7 mm, having opening 19.05 × 19.05 mm. Experimental tests were conducted on samples of these meshes. The objective of this study was to investigate the behaviour of the welded mesh and hexagonal Metal mesh. The result shows that the tension load carrying capacity of welded mesh of Ø 2.7 mm of 0° orientation is good as compared to Ø2.3 mm mesh and ductility of hexagonal Metal mesh is good in behaviour.

  12. Unstructured mesh based elastic wave modelling on GPU: a double-mesh grid method

    Science.gov (United States)

    Yang, Kai; Zhang, Jianfeng; Gao, Hongwei

    2017-11-01

    We present an unstructured mesh based numerical technique for modelling elastic wave propagation in heterogeneous media with complex geometrical settings. The scheme is developed by adapting the so-called grid method with a double-mesh implementation. The double-mesh is generated by subdividing each triangular grid of the first-level mesh into a group of congruent smaller grids with equally dividing each edge of the triangle. The resulting double-mesh grid method incorporates the advantages of structured- and unstructured-mesh schemes. The irregular, unstructured first-level mesh, which is generated by centroidal Voronoi tessellation based on Delaunay triangulation with a velocity-dependent density function, can accurately describe the surface topography and interfaces, and the size of the grid cells can vary according to local velocities. Congruent smaller grids within each grid cell of the first-level mesh greatly reduce the memory requirement of geometrical coefficients compared to a whole irregular, unstructured mesh. Applying the double-mesh approach can also alleviate the discontinuity of memory accessing mainly caused by adoption of fully unstructured mesh. As a result, the GPU implementation of the proposed scheme can obtain a high speedup rate. Numerical examples demonstrate the good behaviour of the double-mesh elastic grid method.

  13. White Dwarf Mergers on Adaptive Meshes

    Science.gov (United States)

    Katz, Maximilian Peter

    The mergers of binary white dwarf systems are potential progenitors of astrophysical explosions such as Type Ia supernovae. These white dwarfs can merge either by orbital decay through the emission of gravitational waves or by direct collisions as a result of orbital perturbations. The coalescence of the stars may ignite nuclear fusion, resulting in the destruction of both stars through a thermonuclear runaway and ensuing detonation. The goal of this dissertation is to simulate binary white dwarf systems using the techniques of computational fluid dynamics and therefore to understand what numerical techniques are necessary to obtain accurate dynamical evolution of the system, as well as to learn what conditions are necessary to enable a realistic detonation. For this purpose I have used software that solves the relevant fluid equations, the Poisson equation for self-gravity, and the systems governing nuclear reactions between atomic species. These equations are modeled on a computational domain that uses the technique of adaptive mesh refinement to have the highest spatial resolution in the areas of the domain that are most sensitive to the need for accurate numerical evolution. I have identified that the most important obstacles to accurate evolution are the numerical violation of conservation of energy and angular momentum in the system, and the development of numerically seeded thermonuclear detonations that do not bear resemblance to physically correct detonations. I then developed methods for ameliorating these problems, and determined what metrics can be used for judging whether a given white dwarf merger simulation is trustworthy. This involved the development of a number of algorithmic improvements to the simulation software, which I describe. Finally, I performed high-resolution simulations of typical cases of white dwarf mergers and head-on collisions to demonstrate the impacts of these choices. The results of these simulations and the corresponding

  14. Adaptive mesh refinement in titanium

    Energy Technology Data Exchange (ETDEWEB)

    Colella, Phillip; Wen, Tong

    2005-01-21

    In this paper, we evaluate Titanium's usability as a high-level parallel programming language through a case study, where we implement a subset of Chombo's functionality in Titanium. Chombo is a software package applying the Adaptive Mesh Refinement methodology to numerical Partial Differential Equations at the production level. In Chombo, the library approach is used to parallel programming (C++ and Fortran, with MPI), whereas Titanium is a Java dialect designed for high-performance scientific computing. The performance of our implementation is studied and compared with that of Chombo in solving Poisson's equation based on two grid configurations from a real application. Also provided are the counts of lines of code from both sides.

  15. Scalable L-infinite coding of meshes.

    Science.gov (United States)

    Munteanu, Adrian; Cernea, Dan C; Alecu, Alin; Cornelis, Jan; Schelkens, Peter

    2010-01-01

    The paper investigates the novel concept of local-error control in mesh geometry encoding. In contrast to traditional mesh-coding systems that use the mean-square error as target distortion metric, this paper proposes a new L-infinite mesh-coding approach, for which the target distortion metric is the L-infinite distortion. In this context, a novel wavelet-based L-infinite-constrained coding approach for meshes is proposed, which ensures that the maximum error between the vertex positions in the original and decoded meshes is lower than a given upper bound. Furthermore, the proposed system achieves scalability in L-infinite sense, that is, any decoding of the input stream will correspond to a perfectly predictable L-infinite distortion upper bound. An instantiation of the proposed L-infinite-coding approach is demonstrated for MESHGRID, which is a scalable 3D object encoding system, part of MPEG-4 AFX. In this context, the advantages of scalable L-infinite coding over L-2-oriented coding are experimentally demonstrated. One concludes that the proposed L-infinite mesh-coding approach guarantees an upper bound on the local error in the decoded mesh, it enables a fast real-time implementation of the rate allocation, and it preserves all the scalability features and animation capabilities of the employed scalable mesh codec.

  16. Stretchable Mesh for Cavity Noise Reduction

    Science.gov (United States)

    Khorrami, Mehdi R. (Inventor)

    2017-01-01

    A stretchable mesh material extends across the opening of a cavity of the landing gear of an aircraft when the landing gear is in the deployed position. The mesh material alters the flow of air across the opening of the landing gear cavity and significantly reduces the amount of noise produced by the wheel well at low-to-mid frequencies.

  17. 7th International Meshing Roundtable '98

    Energy Technology Data Exchange (ETDEWEB)

    Eldred, T.J.

    1998-10-01

    The goal of the 7th International Meshing Roundtable is to bring together researchers and developers from industry, academia, and government labs in a stimulating, open environment for the exchange of technical information related to the meshing process. In the past, the Roundtable has enjoyed significant participation from each of these groups from a wide variety of countries.

  18. Mesh Sutured Repairs of Abdominal Wall Defects

    Science.gov (United States)

    Lanier, Steven T.; Jordan, Sumanas W.; Miller, Kyle R.; Ali, Nada A.; Stock, Stuart R.

    2016-01-01

    Background: A new closure technique is introduced, which uses strips of macroporous polypropylene mesh as a suture for closure of abdominal wall defects due to failures of standard sutures and difficulties with planar meshes. Methods: Strips of macroporous polypropylene mesh of 2 cm width were passed through the abdominal wall and tied as simple interrupted sutures. The surgical technique and surgical outcomes are presented. Results: One hundred and seven patients underwent a mesh sutured abdominal wall closure. Seventy-six patients had preoperative hernias, and the mean hernia width by CT scan for those with scans was 9.1 cm. Forty-nine surgical fields were clean-contaminated, contaminated, or dirty. Five patients had infections within the first 30 days. Only one knot was removed as an office procedure. Mean follow-up at 234 days revealed 4 recurrent hernias. Conclusions: Mesh sutured repairs reliably appose tissue under tension using concepts of force distribution and resistance to suture pull-through. The technique reduces the amount of foreign material required in comparison to sheet meshes, and avoids the shortcomings of monofilament sutures. Mesh sutured closures seem to be tolerant of bacterial contamination with low hernia recurrence rates and have replaced our routine use of mesh sheets and bioprosthetic grafts. PMID:27757361

  19. Laparoscopic Pelvic Floor Repair Using Polypropylene Mesh

    Directory of Open Access Journals (Sweden)

    Shih-Shien Weng

    2008-09-01

    Conclusion: Laparoscopic pelvic floor repair using a single piece of polypropylene mesh combined with uterosacral ligament suspension appears to be a feasible procedure for the treatment of advanced vaginal vault prolapse and enterocele. Fewer mesh erosions and postoperative pain syndromes were seen in patients who had no previous pelvic floor reconstructive surgery.

  20. Absorbable Meshes in Inguinal Hernia Surgery

    DEFF Research Database (Denmark)

    Öberg, Stina; Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    PURPOSE: Absorbable meshes used in inguinal hernia repair are believed to result in less chronic pain than permanent meshes, but concerns remain whether absorbable meshes result in an increased risk of recurrence. The aim of this study was to present an overview of the advantages and limitations...... of fully absorbable meshes for the repair of inguinal hernias, focusing mainly on postoperative pain and recurrence. METHODS: This systematic review with meta-analyses is based on searches in PubMed, Embase, Cochrane, and Psychinfo. Included study designs were case series, cohort studies, randomized...... controlled trials (RCTs), and non-RCTs. Studies had to include adult patients undergoing an inguinal hernia repair with a fully absorbable mesh. RESULTS: The meta-analyses showed no difference in recurrence rates (median 18 months follow-up) and chronic pain rates (1 year follow-up) between absorbable...

  1. Laser patterned carbon–polyethylene mesh electrodes for wound diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Phair, Jolene; Joshi, Mayank; Benson, John; McDonald, Damian; Davis, James, E-mail: james.davis@ulster.ac.uk

    2014-02-14

    Carbon loaded polyethylene films were selected as the base substrate for a mechanically flexible and conductive sensing material for use wound monitoring technologies. The films were processed using laser ablation of the surface to increase the effective surface area of the electrode and then subject to an oxidative electrochemical etch to improve the electron transfer kinetics. The surface morphology of the resulting films was analysed and the electrode performance in relation to monitoring uric acid, a key wound biomarker, was optimized. A prototype smart bandage was designed, based on interfacing the mesh to a portable potentiostat, and the response to urate and potential interferences assessed. - Highlights: • Innovative use of a carbon–polyethylene mesh for wound sensing applications. • Electroanalytical characterisation of a mechanically flexible conductive film. • Design and preliminary characterisation of an integrated smart bandage.

  2. A novel surface mesh deformation method for handling wing-fuselage intersections

    Directory of Open Access Journals (Sweden)

    Mario Jaime Martin-Burgos

    2017-02-01

    Full Text Available This paper describes a method for mesh adaptation in the presence of intersections, such as wing-fuselage. Automatic optimization tools, using Computational Fluid Dynamics (CFD simulations, face the problem to adapt the computational grid upon deformations of the boundary surface. When mesh regeneration is not feasible, due to the high cost to build up the computational grid, mesh deformation techniques are considered a cheap approach to adapt the mesh to changes on the geometry. Mesh adaptation is a well-known subject in the literature; however, there is very little work which deals with moving intersections. Without a proper treatment of the intersections, the use of automatic optimization methods for aircraft design is limited to individual components. The proposed method takes advantage of the CAD description, which usually comes in the form of Non-Uniform Rational B-Splines (NURBS patches. This paper describes an algorithm to recalculate the intersection line between two parametric surfaces. Then, the surface mesh is adapted to the moving intersection in parametric coordinates. Finally, the deformation is propagated through the volumetric mesh. The proposed method is tested with the DLR F6 wing-body configuration.

  3. Head Lice

    Science.gov (United States)

    ... 1044-1047. Canyon, DV, Speare R, et al . “Spatial and kinetic factors for the transfer of head ... for children. Natural products can give parents false sense of safety If using a natural product or ...

  4. Head First Statistics

    CERN Document Server

    Griffiths, Dawn

    2009-01-01

    Wouldn't it be great if there were a statistics book that made histograms, probability distributions, and chi square analysis more enjoyable than going to the dentist? Head First Statistics brings this typically dry subject to life, teaching you everything you want and need to know about statistics through engaging, interactive, and thought-provoking material, full of puzzles, stories, quizzes, visual aids, and real-world examples. Whether you're a student, a professional, or just curious about statistical analysis, Head First's brain-friendly formula helps you get a firm grasp of statistics

  5. Evaluation of disturbing effect of mesh holes in wide-acceptance-angle electrostatic mesh lenses

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiroyuki, E-mail: hmatsuda@ms.naist.jp [Nara Institute of Science and Technology (NAIST), 8916-5 Takayama, Ikoma, Nara 630-0192 (Japan); Tóth, László [University of Debrecen, H-4032 Debrecen, Egyetemtér 1 (Hungary); Matsui, Fumihiko; Daimon, Hiroshi [Nara Institute of Science and Technology (NAIST), 8916-5 Takayama, Ikoma, Nara 630-0192 (Japan)

    2014-08-15

    Highlights: • A practical method to evaluate the disturbing effect of mesh holes in electrostatic mesh lenses is described. • The method evaluates the image blur due to a mesh hole using the Davisson–Calbick formula. • The method considers the discrepancy in focal length in tangential and saggital planes. • The method can be applied to wide-acceptance-angle electrostatic mesh lenses. • The mesh-hole effect of a wide-acceptance-angle electrostatic lens considerably decreases with increasing the emission angle. - Abstract: A curved mesh electrode introduced into an electrostatic lens enables spherical aberration correction over a wide acceptance angle. This technique has great advantages in X-ray photoelectron spectroscopy and related techniques, allowing considerable increase in photoelectron intensity and efficient measurement of photoelectron angular distribution. However, the use of meshes severely limits spatial resolution, as the image produced through each mesh hole is blurred by the lens action of the hole. This feature is studied in detail in this paper, in order to determine the best possible resolution that can be attained in electrostatic mesh lenses with wide acceptance angles. A simple way to evaluate the mesh-hole effect is to use the Davisson–Calbick formula, which expresses the focal length of a single-aperture lens. To make this approach more feasible, we take into account the influence of the angle of incidence to a mesh hole. We characterize the image blur due to each mesh hole in two orthogonal directions, considering the discrepancy in focal length in tangential and sagittal planes. After the demonstration of the validity of our approach in a simple example, the mesh-hole effect of a wide-acceptance-angle electrostatic mesh lens is evaluated.

  6. Automatic Mesh Generation of Hybrid Mesh on Valves in Multiple Positions in Feedline Systems

    Science.gov (United States)

    Ross, Douglass H.; Ito, Yasushi; Dorothy, Fredric W.; Shih, Alan M.; Peugeot, John

    2010-01-01

    Fluid flow simulations through a valve often require evaluation of the valve in multiple opening positions. A mesh has to be generated for the valve for each position and compounding. The problem is the fact that the valve is typically part of a larger feedline system. In this paper, we propose to develop a system to create meshes for feedline systems with parametrically controlled valve openings. Herein we outline two approaches to generate the meshes for a valve in a feedline system at multiple positions. There are two issues that must be addressed. The first is the creation of the mesh on the valve for multiple positions. The second is the generation of the mesh for the total feedline system including the valve. For generation of the mesh on the valve, we will describe the use of topology matching and mesh generation parameter transfer. For generation of the total feedline system, we will describe two solutions that we have implemented. In both cases the valve is treated as a component in the feedline system. In the first method the geometry of the valve in the feedline system is replaced with a valve at a different opening position. Geometry is created to connect the valve to the feedline system. Then topology for the valve is created and the portion of the topology for the valve is topology matched to the standard valve in a different position. The mesh generation parameters are transferred and then the volume mesh for the whole feedline system is generated. The second method enables the user to generate the volume mesh on the valve in multiple open positions external to the feedline system, to insert it into the volume mesh of the feedline system, and to reduce the amount of computer time required for mesh generation because only two small volume meshes connecting the valve to the feedline mesh need to be updated.

  7. Comparison of the Bronchodilative Effects of Salbutamol Delivered via Three Mesh Nebulizers in Children with Bronchial Asthma

    Directory of Open Access Journals (Sweden)

    Fumitake Kurosaka

    2009-01-01

    Conclusions: Overall, all 3 mesh nebulizers were useful devices in treating bronchial asthma, although some differences in lung function improvement were evident. The limitation of this study is that subjects did not include patients with severe asthma attacks.

  8. Elliptic Solvers for Adaptive Mesh Refinement Grids

    Energy Technology Data Exchange (ETDEWEB)

    Quinlan, D.J.; Dendy, J.E., Jr.; Shapira, Y.

    1999-06-03

    We are developing multigrid methods that will efficiently solve elliptic problems with anisotropic and discontinuous coefficients on adaptive grids. The final product will be a library that provides for the simplified solution of such problems. This library will directly benefit the efforts of other Laboratory groups. The focus of this work is research on serial and parallel elliptic algorithms and the inclusion of our black-box multigrid techniques into this new setting. The approach applies the Los Alamos object-oriented class libraries that greatly simplify the development of serial and parallel adaptive mesh refinement applications. In the final year of this LDRD, we focused on putting the software together; in particular we completed the final AMR++ library, we wrote tutorials and manuals, and we built example applications. We implemented the Fast Adaptive Composite Grid method as the principal elliptic solver. We presented results at the Overset Grid Conference and other more AMR specific conferences. We worked on optimization of serial and parallel performance and published several papers on the details of this work. Performance remains an important issue and is the subject of continuing research work.

  9. A randomized controlled experimental study comparing chitosan coated polypropylene mesh and Proceed™ mesh for abdominal wall defect closure

    Directory of Open Access Journals (Sweden)

    S.T. Jayanth

    2015-12-01

    Conclusion: Chitosan coated polypropylene mesh was found to have similar efficacy to Proceed™ mesh. Chitosan coated polypropylene mesh, can act as an anti adhesive barrier when used in the repair of incisional hernias and abdominal wall defects.

  10. A single centre comparative study of laparoscopic mesh rectopexy versus suture rectopexy

    Directory of Open Access Journals (Sweden)

    Manash Ranjan Sahoo

    2014-01-01

    Full Text Available Aim: The aim of our study is to compare the results of laparoscopic mesh vs. suture rectopexy. Materials and Methods: In this retrospective study, 70 patients including both male and female of age ranging between 20 years and 65 years (mean 42.5 yrs were subjected to laparoscopic rectopexy during the period between March 2007 and June 2012, of which 38 patients underwent laparoscopic mesh rectopexy and 32 patients laparoscopic suture rectopexy. These patients were followed up for a mean period of 12 months assessing first bowel movement, hospital stay, duration of surgery, faecal incontinence, constipation, recurrence and morbidity. Results: Duration of surgery was 100.8 ± 12.4 minutes in laparoscopic suture rectopexy and 120 ± 10.8 min in laparoscopic mesh rectopexy. Postoperatively, the mean time for the first bowel movement was 38 hrs and 40 hrs, respectively, for suture and mesh rectopexy. Mean hospital stay was five (range: 4-7 days. There was no significant postoperative complication except for one port site infection in mesh rectopexy group. Patients who had varying degree of incontinence preoperatively showed improvement after surgery. Eleven out of 18 (61.1% patients who underwent laparoscopic suture rectopexy as compared to nine of 19 (47.3% patients who underwent laparoscopic mesh rectopexy improved as regards constipation after surgery. Conclusion: There were no significant difference in both groups who underwent surgery except for patients undergoing suture rectopexy had better symptomatic improvement of continence and constipation. Also, cost of mesh used in laparoscopic mesh rectopexy is absent in lap suture rectopexy group. To conclude that laparoscopic suture rectopexy is a safe and feasible procedure and have comparable results as regards operative time, morbidity, bowel function, cost and recurrence or even slightly better results than mesh rectopexy.

  11. Quadratically consistent projection from particles to mesh

    CERN Document Server

    Duque, Daniel

    2016-01-01

    The advantage of particle Lagrangian methods in computational fluid dynamics is that advection is accurately modeled. However, this complicates the calculation of space derivatives. If a mesh is employed, it must be updated at each time step. On the other hand, fixed mesh, Eulerian, formulations benefit from the mesh being defined at the beginning of the simulation, but feature non-linear advection terms. It therefore seems natural to combine the two approaches, using a fixed mesh to perform calculations related to space derivatives, and using the particles to advect the information with time. The idea of combining Lagrangian particles and a fixed mesh goes back to Particle-in-Cell methods, and is here considered within the context of the finite element method (FEM) for the fixed mesh, and the particle FEM (pFEM) for the particles. Our results, in agreement with recent works, show that interpolation ("projection") errors, especially from particles to mesh, are the culprits of slow convergence of the method if...

  12. Fog water collection effectiveness: Mesh intercomparisons

    Science.gov (United States)

    Fernandez, Daniel; Torregrosa, Alicia; Weiss-Penzias, Peter; Zhang, Bong June; Sorensen, Deckard; Cohen, Robert; McKinley, Gareth; Kleingartner, Justin; Oliphant, Andrew; Bowman, Matthew

    2018-01-01

    To explore fog water harvesting potential in California, we conducted long-term measurements involving three types of mesh using standard fog collectors (SFC). Volumetric fog water measurements from SFCs and wind data were collected and recorded in 15-minute intervals over three summertime fog seasons (2014–2016) at four California sites. SFCs were deployed with: standard 1.00 m2 double-layer 35% shade coefficient Raschel; stainless steel mesh coated with the MIT-14 hydrophobic formulation; and FogHa-Tin, a German manufactured, 3-dimensional spacer fabric deployed in two orientations. Analysis of 3419 volumetric samples from all sites showed strong relationships between mesh efficiency and wind speed. Raschel mesh collected 160% more fog water than FogHa-Tin at wind speeds less than 1 m s–1 and 45% less for wind speeds greater than 5 m s–1. MIT-14 coated stainless-steel mesh collected more fog water than Raschel mesh at all wind speeds. At low wind speeds of water when the warp of the weave was oriented vertically, per manufacturer specification, than when the warp of the weave was oriented horizontally. Time series measurements of three distinct mesh across similar wind regimes revealed inconsistent lags in fog water collection and inconsistent performance. Since such differences occurred under similar wind-speed regimes, we conclude that other factors play important roles in mesh performance, including in-situ fog event and aerosol dynamics that affect droplet-size spectra and droplet-to-mesh surface interactions.

  13. Mesh optimization for microbial fuel cell cathodes constructed around stainless steel mesh current collectors

    KAUST Repository

    Zhang, Fang

    2011-02-01

    Mesh current collectors made of stainless steel (SS) can be integrated into microbial fuel cell (MFC) cathodes constructed of a reactive carbon black and Pt catalyst mixture and a poly(dimethylsiloxane) (PDMS) diffusion layer. It is shown here that the mesh properties of these cathodes can significantly affect performance. Cathodes made from the coarsest mesh (30-mesh) achieved the highest maximum power of 1616 ± 25 mW m-2 (normalized to cathode projected surface area; 47.1 ± 0.7 W m-3 based on liquid volume), while the finest mesh (120-mesh) had the lowest power density (599 ± 57 mW m-2). Electrochemical impedance spectroscopy showed that charge transfer and diffusion resistances decreased with increasing mesh opening size. In MFC tests, the cathode performance was primarily limited by reaction kinetics, and not mass transfer. Oxygen permeability increased with mesh opening size, accounting for the decreased diffusion resistance. At higher current densities, diffusion became a limiting factor, especially for fine mesh with low oxygen transfer coefficients. These results demonstrate the critical nature of the mesh size used for constructing MFC cathodes. © 2010 Elsevier B.V. All rights reserved.

  14. Engagement of Metal Debris into Gear Mesh

    Science.gov (United States)

    handschuh, Robert F.; Krantz, Timothy L.

    2010-01-01

    A series of bench-top experiments was conducted to determine the effects of metallic debris being dragged through meshing gear teeth. A test rig that is typically used to conduct contact fatigue experiments was used for these tests. Several sizes of drill material, shim stock and pieces of gear teeth were introduced and then driven through the meshing region. The level of torque required to drive the "chip" through the gear mesh was measured. From the data gathered, chip size sufficient to jam the mechanism can be determined.

  15. Mesh Processing in Medical Image Analysis

    DEFF Research Database (Denmark)

    The following topics are dealt with: mesh processing; medical image analysis; interactive freeform modeling; statistical shape analysis; clinical CT images; statistical surface recovery; automated segmentation; cerebral aneurysms; and real-time particle-based representation....

  16. Obtuse triangle suppression in anisotropic meshes

    KAUST Repository

    Sun, Feng

    2011-12-01

    Anisotropic triangle meshes are used for efficient approximation of surfaces and flow data in finite element analysis, and in these applications it is desirable to have as few obtuse triangles as possible to reduce the discretization error. We present a variational approach to suppressing obtuse triangles in anisotropic meshes. Specifically, we introduce a hexagonal Minkowski metric, which is sensitive to triangle orientation, to give a new formulation of the centroidal Voronoi tessellation (CVT) method. Furthermore, we prove several relevant properties of the CVT method with the newly introduced metric. Experiments show that our algorithm produces anisotropic meshes with much fewer obtuse triangles than using existing methods while maintaining mesh anisotropy. © 2011 Elsevier B.V. All rights reserved.

  17. Metal Mesh Filters for Terahertz Receivers Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The technical objective of this SBIR program is to develop and demonstrate metal mesh filters for use in NASA's low noise receivers for terahertz astronomy and...

  18. Pectus excavatum repair using Prolene polypropylene mesh.

    Science.gov (United States)

    Rasihashemi, Seyed Ziaeddin; Ramouz, Ali

    2016-02-01

    We aimed to assess the clinical outcomes of our surgical technique for repair of pectus excavatum using Prolene polypropylene mesh. Among 29 patients with pectus excavatum, the major complaint was cosmetic dissatisfaction, and the main symptom was exercise dyspnea in 15 patients. The Haller index used to assess pectus excavatum severity; it was significant in 22 patients. In all patients, a 2-layer sheet of Prolene polypropylene mesh was placed behind the sternum. No serious complication was observed postoperatively, and all patients were satisfied with the cosmetic result. Mitral valve prolapse improved in all cases after 3 months. Spirometry revealed improved pulmonary function after surgery. With due attention to the advantages of Prolene polypropylene mesh, such as remaining permanently in place, adapting to various stresses encountered in the body, resisting degradation by tissue enzymes, and trimming without unraveling, we concluded that this mesh is suitable for use as posterior sternal support in pectus excavatum patients. © The Author(s) 2016.

  19. LR: Compact connectivity representation for triangle meshes

    Energy Technology Data Exchange (ETDEWEB)

    Gurung, T; Luffel, M; Lindstrom, P; Rossignac, J

    2011-01-28

    We propose LR (Laced Ring) - a simple data structure for representing the connectivity of manifold triangle meshes. LR provides the option to store on average either 1.08 references per triangle or 26.2 bits per triangle. Its construction, from an input mesh that supports constant-time adjacency queries, has linear space and time complexity, and involves ordering most vertices along a nearly-Hamiltonian cycle. LR is best suited for applications that process meshes with fixed connectivity, as any changes to the connectivity require the data structure to be rebuilt. We provide an implementation of the set of standard random-access, constant-time operators for traversing a mesh, and show that LR often saves both space and traversal time over competing representations.

  20. Shape space exploration of constrained meshes

    KAUST Repository

    Yang, Yongliang

    2011-12-12

    We present a general computational framework to locally characterize any shape space of meshes implicitly prescribed by a collection of non-linear constraints. We computationally access such manifolds, typically of high dimension and co-dimension, through first and second order approximants, namely tangent spaces and quadratically parameterized osculant surfaces. Exploration and navigation of desirable subspaces of the shape space with regard to application specific quality measures are enabled using approximants that are intrinsic to the underlying manifold and directly computable in the parameter space of the osculant surface. We demonstrate our framework on shape spaces of planar quad (PQ) meshes, where each mesh face is constrained to be (nearly) planar, and circular meshes, where each face has a circumcircle. We evaluate our framework for navigation and design exploration on a variety of inputs, while keeping context specific properties such as fairness, proximity to a reference surface, etc. © 2011 ACM.

  1. Assignment of fields from particles to mesh

    CERN Document Server

    Duque, Daniel

    2016-01-01

    In Computational Fluid Dynamics there have been many attempts to combine the power of a fixed mesh on which to carry out spatial calculations with that of a set of particles that moves following the velocity field. These ideas indeed go back to Particle-in-Cell methods, proposed about 60 years ago. Of course, some procedure is needed to transfer field information between particles and mesh. There are many possible choices for this "assignment", or "projection". Several requirements may guide this choice. Two well-known ones are conservativity and stability, which apply to volume integrals of the fields. An additional one is here considered: preservation of information. This means that mesh interpolation, followed by mesh assignment, should leave the field values invariant. The resulting methods are termed "mass" assignments due to their strong similarities with the Finite Element Method. We test several procedures, including the well-known FLIP, on three scenarios: simple 1D convection, 2D convection of Zales...

  2. Shape space exploration of constrained meshes

    KAUST Repository

    Yang, Yongliang

    2011-01-01

    We present a general computational framework to locally characterize any shape space of meshes implicitly prescribed by a collection of non-linear constraints. We computationally access such manifolds, typically of high dimension and co-dimension, through first and second order approximants, namely tangent spaces and quadratically parameterized osculant surfaces. Exploration and navigation of desirable subspaces of the shape space with regard to application specific quality measures are enabled using approximants that are intrinsic to the underlying manifold and directly computable in the parameter space of the osculant surface. We demonstrate our framework on shape spaces of planar quad (PQ) meshes, where each mesh face is constrained to be (nearly) planar, and circular meshes, where each face has a circumcircle. We evaluate our framework for navigation and design exploration on a variety of inputs, while keeping context specific properties such as fairness, proximity to a reference surface, etc.

  3. Quadrilateral/hexahedral finite element mesh coarsening

    Science.gov (United States)

    Staten, Matthew L; Dewey, Mark W; Scott, Michael A; Benzley, Steven E

    2012-10-16

    A technique for coarsening a finite element mesh ("FEM") is described. This technique includes identifying a coarsening region within the FEM to be coarsened. Perimeter chords running along perimeter boundaries of the coarsening region are identified. The perimeter chords are redirected to create an adaptive chord separating the coarsening region from a remainder of the FEM. The adaptive chord runs through mesh elements residing along the perimeter boundaries of the coarsening region. The adaptive chord is then extracted to coarsen the FEM.

  4. MHD simulations on an unstructured mesh

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, H.R. [New York Univ., NY (United States); Park, W.; Belova, E.; Fu, G.Y. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Longcope, D.W. [Univ. of Montana, Missoula, MT (United States); Sugiyama, L.E. [Massachusetts Inst. of Tech., Cambridge, MA (United States)

    1998-12-31

    Two reasons for using an unstructured computational mesh are adaptivity, and alignment with arbitrarily shaped boundaries. Two codes which use finite element discretization on an unstructured mesh are described. FEM3D solves 2D and 3D RMHD using an adaptive grid. MH3D++, which incorporates methods of FEM3D into the MH3D generalized MHD code, can be used with shaped boundaries, which might be 3D.

  5. Mesh geometry impact on Micromegas performance with an Exchangeable Mesh prototype

    Energy Technology Data Exchange (ETDEWEB)

    Kuger, F., E-mail: fabian.kuger@cern.ch [CERN, Geneva (Switzerland); Julius-Maximilians-Universität, Würzburg (Germany); Bianco, M.; Iengo, P. [CERN, Geneva (Switzerland); Sekhniaidze, G. [CERN, Geneva (Switzerland); Universita e INFN, Napoli (Italy); Veenhof, R. [Uludağ University, Bursa (Turkey); Wotschack, J. [CERN, Geneva (Switzerland)

    2016-07-11

    The reconstruction precision of gaseous detectors is limited by losses of primary electrons during signal formation. In addition to common gas related losses, like attachment, Micromegas suffer from electron absorption during its transition through the micro mesh. This study aims for a deepened understanding of electron losses and their dependency on the mesh geometry. It combines experimental results obtained with a novel designed Exchangeable Mesh Micromegas (ExMe) and advanced microscopic-tracking simulations (ANSYS and Garfield++) of electron drift and mesh transition.

  6. Robust moving mesh algorithms for hybrid stretched meshes: Application to moving boundaries problems

    Science.gov (United States)

    Landry, Jonathan; Soulaïmani, Azzeddine; Luke, Edward; Ben Haj Ali, Amine

    2016-12-01

    A robust Mesh-Mover Algorithm (MMA) approach is designed to adapt meshes of moving boundaries problems. A new methodology is developed from the best combination of well-known algorithms in order to preserve the quality of initial meshes. In most situations, MMAs distribute mesh deformation while preserving a good mesh quality. However, invalid meshes are generated when the motion is complex and/or involves multiple bodies. After studying a few MMA limitations, we propose the following approach: use the Inverse Distance Weighting (IDW) function to produce the displacement field, then apply the Geometric Element Transformation Method (GETMe) smoothing algorithms to improve the resulting mesh quality, and use an untangler to revert negative elements. The proposed approach has been proven efficient to adapt meshes for various realistic aerodynamic motions: a symmetric wing that has suffered large tip bending and twisting and the high-lift components of a swept wing that has moved to different flight stages. Finally, the fluid flow problem has been solved on meshes that have moved and they have produced results close to experimental ones. However, for situations where moving boundaries are too close to each other, more improvements need to be made or other approaches should be taken, such as an overset grid method.

  7. The finite element method in making up meshes in ANSYS Meshing for CFD models

    Directory of Open Access Journals (Sweden)

    Віктор Іванович Троханяк

    2015-11-01

    Full Text Available Method of finite elements (FEM is used in calculating tasks of hydrodynamics and heat transfer tasks. The essence of the method consists in the approximate solution of a variational task. To formulate this task a functional concept is used. The type of a functional is different for different tasks and is selected through a special choice. Currently FEM is widely used in calculating the strength and in solving tasks of heat transfer in solids. However, it can be applied in calculating the flow of liquids and gases. There are also methods that combine elements of the finite volumes and finite elements methods. The combination of these methods make it possible to use a wide range of computational meshes ( tetragonal meshes, pyramidal meshes, prismatic meshes, polyhedral meshes what is necessary for solving tasks with complex geometry. This approach is used by CFD packages Ansys CFX, Ansys Fluent, Star-CD, Star-CCM +, Comsol and others. The method and the analysis of 2D mesh were carried out, using a method of final elements in ANSYS Meshing for heat exchangers with an inline arrangement of tubes in banks and with their curvilinear arrangement in compact banks of tubes of a new design. Particular features were considered and the algorithm of making up a mesh was developed for tasks of hydraulic and gas dynamics and thermal mass transfer. The most optimum and qualitative meshes for CFD models were chosen

  8. Unstructured Mesh Movement and Viscous Mesh Generation for CFD-Based Design Optimization Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovations proposed are twofold: 1) a robust unstructured mesh movement method able to handle isotropic (Euler), anisotropic (viscous), mixed element (hybrid)...

  9. Electric field calculations in brain stimulation based on finite elements: an optimized processing pipeline for the generation and usage of accurate individual head models.

    Science.gov (United States)

    Windhoff, Mirko; Opitz, Alexander; Thielscher, Axel

    2013-04-01

    The need for realistic electric field calculations in human noninvasive brain stimulation is undisputed to more accurately determine the affected brain areas. However, using numerical techniques such as the finite element method (FEM) is methodologically complex, starting with the creation of accurate head models to the integration of the models in the numerical calculations. These problems substantially limit a more widespread application of numerical methods in brain stimulation up to now. We introduce an optimized processing pipeline allowing for the automatic generation of individualized high-quality head models from magnetic resonance images and their usage in subsequent field calculations based on the FEM. The pipeline starts by extracting the borders between skin, skull, cerebrospinal fluid, gray and white matter. The quality of the resulting surfaces is subsequently improved, allowing for the creation of tetrahedral volume head meshes that can finally be used in the numerical calculations. The pipeline integrates and extends established (and mainly free) software for neuroimaging, computer graphics, and FEM calculations into one easy-to-use solution. We demonstrate the successful usage of the pipeline in six subjects, including field calculations for transcranial magnetic stimulation and transcranial direct current stimulation. The quality of the head volume meshes is validated both in terms of capturing the underlying anatomy and of the well-shapedness of the mesh elements. The latter is crucial to guarantee the numerical robustness of the FEM calculations. The pipeline will be released as open-source, allowing for the first time to perform realistic field calculations at an acceptable methodological complexity and moderate costs. Copyright © 2011 Wiley Periodicals, Inc.

  10. Automatic Scheme Selection for Toolkit Hex Meshing

    Energy Technology Data Exchange (ETDEWEB)

    TAUTGES,TIMOTHY J.; WHITE,DAVID R.

    1999-09-27

    Current hexahedral mesh generation techniques rely on a set of meshing tools, which when combined with geometry decomposition leads to an adequate mesh generation process. Of these tools, sweeping tends to be the workhorse algorithm, accounting for at least 50% of most meshing applications. Constraints which must be met for a volume to be sweepable are derived, and it is proven that these constraints are necessary but not sufficient conditions for sweepability. This paper also describes a new algorithm for detecting extruded or sweepable geometries. This algorithm, based on these constraints, uses topological and local geometric information, and is more robust than feature recognition-based algorithms. A method for computing sweep dependencies in volume assemblies is also given. The auto sweep detect and sweep grouping algorithms have been used to reduce interactive user time required to generate all-hexahedral meshes by filtering out non-sweepable volumes needing further decomposition and by allowing concurrent meshing of independent sweep groups. Parts of the auto sweep detect algorithm have also been used to identify independent sweep paths, for use in volume-based interval assignment.

  11. Mesh-type acoustic vector sensor

    Science.gov (United States)

    Zalalutdinov, M. K.; Photiadis, D. M.; Szymczak, W. G.; McMahon, J. W.; Bucaro, J. A.; Houston, B. H.

    2017-07-01

    Motivated by the predictions of a theoretical model developed to describe the acoustic flow force exerted on closely spaced nano-fibers in a viscous medium, we have demonstrated a novel concept for a particle velocity-based directional acoustic sensor. The central element of the concept exploits the acoustically induced normal displacement of a fine mesh as a measure of the collinear projection of the particle velocity in the sound wave. The key observations are (i) the acoustically induced flow force on an individual fiber within the mesh is nearly independent of the fiber diameter and (ii) the mesh-flow interaction can be well-described theoretically by a nearest neighbor coupling approximation. Scaling arguments based on these two observations indicate that the refinement of the mesh down to the nanoscale leads to significant improvements in performance. The combination of the two dimensional nature of the mesh together with the nanoscale dimensions provides a dramatic gain in the total length of fiber exposed to the flow, leading to a sensitivity enhancement by orders of magnitude. We describe the fabrication of a prototype mesh sensor equipped with optical readout. Preliminary measurements carried out over a considerable bandwidth together with the results of numerical simulations are in good agreement with the theory, thus providing a proof of concept.

  12. [Implants for genital prolapse : Contra mesh surgery].

    Science.gov (United States)

    Hampel, C

    2017-12-01

    Alloplastic transvaginal meshes have become very popular in the surgery of pelvic organ prolapse (POP) as did alloplastic suburethral slings in female stress incontinence surgery, but without adequate supporting data. The simplicity of the mesh procedure facilitates its propagation with acceptance of higher revision and complication rates. Since attending physicians do more and more prolapse surgeries without practicing or teaching alternative techniques, expertise in these alternatives, which might be very useful in cases of recurrence, persistence or complications, is permanently lost. It is doubtful that proper and detailed information about alternatives, risks, and benefits of transvaginal alloplastic meshes is provided to every single prolapse patient according to the recommendations of the German POP guidelines, since the number of implanted meshes exceeds the number of properly indicated mesh candidates by far. Although there is no dissent internationally about the available mesh data, thousands of lawsuits in the USA, insolvency of companies due to claims for compensation and unambiguous warnings from foreign urological societies leave German urogynecologists still unimpressed. The existing literature in pelvic organ prolapse exclusively focusses on POP stage and improvement of that stage with surgical therapy. Instead, typical prolapse symptoms should trigger therapy and improvement of these symptoms should be the utmost treatment goal. It is strongly recommended for liability reasons to obtain specific written informed consent.

  13. Vacuum-assisted wound closure and mesh-mediated fascial traction for open abdomen therapy - a systematic review.

    Science.gov (United States)

    Acosta, Stefan; Björck, Martin; Petersson, Ulf

    2017-01-01

    The aim of this paper was to review the literature on vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) in open abdomen therapy. It was designed as systematic review of observational studies. A Pub Med, EMBASE and Cochrane search from 2007/01-2016/07 was performed combining the Medical Subject Headings "vacuum", "mesh-mediated fascial traction", "temporary abdominal closure", "delayed abdominal closure", "open abdomen", "abdominal compartment syndrome", "negative pressure wound therapy" or "vacuum assisted wound closure". Eleven original studies were found including patients numbering from 7 to 111. Six studies were prospective and five were retrospective. Nine studies were on mixed surgical (n = 9), vascular (n = 6) and trauma (n = 6) patients, while two were exclusively on vascular patients. The primary fascial closure rate per protocol varied from 80-100%. The time to closure of the open abdomen varied between 9-32 days. The entero-atmospheric fistula rate varied from 0-10.0%. The in-hospital survival rate varied from 57-100%. In the largest prospective study, the incisional hernia rate among survivors at 63 months of median follow-up was 54% (27/50), and 16 (33%) repairs out of 48 incisional hernias were performed throughout the study period. The study patients reported lower short form health survey (SF-36) scores than the mean reference population, mainly dependent on the prevalence of major co-morbidities. There was no difference in SF-36 scores or a modified ventral hernia pain questionnaire (VHPQ) at 5 years of follow up between those with versus those without incisional hernias. A high primary fascial closure rate can be achieved with the vacuum-assisted wound closure and meshmediated fascial traction technique in elderly, mainly non-trauma patients, in need of prolonged open abdomen therapy.

  14. Levels of detail analysis of microwave scattering from human head models for brain stroke detection

    Directory of Open Access Journals (Sweden)

    Awais Munawar Qureshi

    2017-11-01

    Full Text Available In this paper, we have presented a microwave scattering analysis from multiple human head models. This study incorporates different levels of detail in the human head models and its effect on microwave scattering phenomenon. Two levels of detail are taken into account; (i Simplified ellipse shaped head model (ii Anatomically realistic head model, implemented using 2-D geometry. In addition, heterogenic and frequency-dispersive behavior of the brain tissues has also been incorporated in our head models. It is identified during this study that the microwave scattering phenomenon changes significantly once the complexity of head model is increased by incorporating more details using magnetic resonance imaging database. It is also found out that the microwave scattering results match in both types of head model (i.e., geometrically simple and anatomically realistic, once the measurements are made in the structurally simplified regions. However, the results diverge considerably in the complex areas of brain due to the arbitrary shape interface of tissue layers in the anatomically realistic head model. After incorporating various levels of detail, the solution of subject microwave scattering problem and the measurement of transmitted and backscattered signals were obtained using finite element method. Mesh convergence analysis was also performed to achieve error free results with a minimum number of mesh elements and a lesser degree of freedom in the fast computational time. The results were promising and the E-Field values converged for both simple and complex geometrical models. However, the E-Field difference between both types of head model at the same reference point differentiated a lot in terms of magnitude. At complex location, a high difference value of 0.04236 V/m was measured compared to the simple location, where it turned out to be 0.00197 V/m. This study also contributes to provide a comparison analysis between the direct and iterative

  15. Randomized clinical trial of self-gripping mesh versus sutured mesh for Lichtenstein hernia repair

    DEFF Research Database (Denmark)

    Jorgensen, L N; Sommer, Thorbjørn; Assaadzadeh, S

    2013-01-01

    BACKGROUND: Many patients develop discomfort after open repair of a groin hernia. It was hypothesized that suture fixation of the mesh is a cause of these symptoms. METHODS: This patient- and assessor-blinded randomized multicentre clinical trial compared a self-gripping mesh (Parietene Progrip......(®) ) and sutured mesh for open primary repair of uncomplicated inguinal hernia by the Lichtenstein technique. Patients were assessed before surgery, on the day of operation, and at 1 and 12 months after surgery. The primary endpoint was moderate or severe symptoms after 12 months, including a combination...... of chronic pain, numbness and discomfort. RESULTS: The intention-to-treat population comprised 163 patients with self-gripping mesh and 171 with sutured mesh. The 12-month prevalence of moderate or severe symptoms was 17·4 and 20·2 per cent respectively (P = 0·573). There were no significant differences...

  16. Light weight meshes in incisional hernia repair

    Directory of Open Access Journals (Sweden)

    Schumpelick Volker

    2006-01-01

    Full Text Available Incisional hernias remain one of the most common surgical complications with a long-term incidence of 10-20%. Increasing evidence of impaired wound healing in these patients supports routine use of an open prefascial, retromuscular mesh repair. Basic pathophysiologic principles dictate that for a successful long-term outcome and prevention of recurrence, a wide overlap underneath healthy tissue is required. Particularly in the neighborhood of osseous structures, only retromuscular placement allows sufficient subduction of the mesh by healthy tissue of at least 5 cm in all directions. Preparation must take into account the special anatomic features of the abdominal wall, especially in the area of the Linea alba and Linea semilunaris. Polypropylene is the material widely used for open mesh repair. New developments have led to low-weight, large-pore polypropylene prostheses, which are adjusted to the physiological requirements of the abdominal wall and permit proper tissue integration. These meshes provide the possibility of forming a scar net instead of a stiff scar plate and therefore help to avoid former known mesh complications.

  17. Is HEADS in our heads?

    DEFF Research Database (Denmark)

    Boisen, Kirsten A; Hertz, Pernille Grarup; Blix, Charlotte

    2016-01-01

    BACKGROUND: Outpatient clinic visits are a window of opportunity to address health risk behaviors and promote a healthier lifestyle among young people. The HEADS (Home, Education, Eating, Activities, Drugs [i.e. substance use including tobacco, alcohol, and illegal drugs], Sexuality [including...... contraception], Safety, Self-harm) interview is a feasible way of exploring health risk behaviors and resilience. OBJECTIVE: The purpose of this study was to evaluate how often HEADS topics were addressed according to young patients and staff in pediatric and adult outpatient clinics. METHODS: We conducted...... care professionals participated. We found only small reported differences between staff and young patients regarding whether home, education, and activity were addressed. However, staff reported twice the rate of addressing smoking, alcohol, illegal drugs, sexuality, and contraception compared to young...

  18. Open preperitoneal groin hernia repair with mesh

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    BACKGROUND: For the repair of inguinal hernias, several surgical methods have been presented where the purpose is to place a mesh in the preperitoneal plane through an open access. The aim of this systematic review was to describe preperitoneal repairs with emphasis on the technique. DATA SOURCES......: A systematic review was conducted and reported according to the PRISMA statement. PubMed, Cochrane library and Embase were searched systematically. Studies were included if they provided clinical data with more than 30 days follow up following repair of an inguinal hernia with an open preperitoneal mesh......-analysis. Open preperitoneal techniques with placement of a mesh through an open approach seem promising compared with the standard anterior techniques. This systematic review provides an overview of these techniques together with a description of surgical methods and clinical outcomes....

  19. Open preperitoneal groin hernia repair with mesh

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    Background For the repair of inguinal hernias, several surgical methods have been presented where the purpose is to place a mesh in the preperitoneal plane through an open access. The aim of this systematic review was to describe preperitoneal repairs with emphasis on the technique. Data sources...... A systematic review was conducted and reported according to the PRISMA statement. PubMed, Cochrane library and Embase were searched systematically. Studies were included if they provided clinical data with more than 30 days follow up following repair of an inguinal hernia with an open preperitoneal mesh......-analysis. Open preperitoneal techniques with placement of a mesh through an open approach seem promising compared with the standard anterior techniques. This systematic review provides an overview of these techniques together with a description of surgical methods and clinical outcomes....

  20. Connectivity editing for quad-dominant meshes

    KAUST Repository

    Peng, Chihan

    2013-08-01

    We propose a connectivity editing framework for quad-dominant meshes. In our framework, the user can edit the mesh connectivity to control the location, type, and number of irregular vertices (with more or fewer than four neighbors) and irregular faces (non-quads). We provide a theoretical analysis of the problem, discuss what edits are possible and impossible, and describe how to implement an editing framework that realizes all possible editing operations. In the results, we show example edits and illustrate the advantages and disadvantages of different strategies for quad-dominant mesh design. © 2013 The Author(s) Computer Graphics Forum © 2013 The Eurographics Association and John Wiley & Sons Ltd.

  1. NASA Lewis Meshed VSAT Workshop meeting summary

    Science.gov (United States)

    Ivancic, William

    1993-11-01

    NASA Lewis Research Center's Space Electronics Division (SED) hosted a workshop to address specific topics related to future meshed very small-aperture terminal (VSAT) satellite communications networks. The ideas generated by this workshop will help to identify potential markets and focus technology development within the commercial satellite communications industry and NASA. The workshop resulted in recommendations concerning these principal points of interest: the window of opportunity for a meshed VSAT system; system availability; ground terminal antenna sizes; recommended multifrequency for time division multiple access (TDMA) uplink; a packet switch design concept for narrowband; and fault tolerance design concepts. This report presents a summary of group presentations and discussion associated with the technological, economic, and operational issues of meshed VSAT architectures that utilize processing satellites.

  2. Calculation of coherent synchrotron radiation using mesh

    Directory of Open Access Journals (Sweden)

    T. Agoh

    2004-05-01

    Full Text Available We develop a new method to simulate coherent synchrotron radiation numerically. It is based on the mesh calculation of the electromagnetic field in the frequency domain. We make an approximation in the Maxwell equation which allows a mesh size much larger than the relevant wavelength so that the computing time is tolerable. Using the equation, we can perform a mesh calculation of coherent synchrotron radiation in transient states with shielding effects by the vacuum chamber. The simulation results obtained by this method are compared with analytic solutions. Though, for the comparison with theories, we adopt simplifications such as longitudinal Gaussian distribution, zero-width transverse distribution, horizontal uniform bend, and a vacuum chamber with rectangular cross section, the method is applicable to general cases.

  3. Mesh control information of windmill designed by Solidwork program

    Science.gov (United States)

    Mulyana, T.; Sebayang, D.; Rafsanjani, A. M. D.; Adani, J. H. D.; Muhyiddin, Y. S.

    2017-12-01

    This paper presents the mesh control information imposed on the windmill already designed. The accuracy of Simulation results is influenced by the quality of the created mesh. However, compared to the quality of the mesh is made, the simulation time running will be done software also increases. The smaller the size of the elements created when making the mesh, the better the mesh quality will be generated. When adjusting the mesh size, there is a slider that acts as the density regulator of the element. SolidWorks Simulation also has Mesh Control facility. Features that can adjust mesh density only in the desired part. The best results of mesh control obtained for both static and thermal simulation have ratio 1.5.

  4. Unstructured Adaptive Meshes: Bad for Your Memory?

    Science.gov (United States)

    Biswas, Rupak; Feng, Hui-Yu; VanderWijngaart, Rob

    2003-01-01

    This viewgraph presentation explores the need for a NASA Advanced Supercomputing (NAS) parallel benchmark for problems with irregular dynamical memory access. This benchmark is important and necessary because: 1) Problems with localized error source benefit from adaptive nonuniform meshes; 2) Certain machines perform poorly on such problems; 3) Parallel implementation may provide further performance improvement but is difficult. Some examples of problems which use irregular dynamical memory access include: 1) Heat transfer problem; 2) Heat source term; 3) Spectral element method; 4) Base functions; 5) Elemental discrete equations; 6) Global discrete equations. Nonconforming Mesh and Mortar Element Method are covered in greater detail in this presentation.

  5. Adaptive mesh refinement for storm surge

    KAUST Repository

    Mandli, Kyle T.

    2014-03-01

    An approach to utilizing adaptive mesh refinement algorithms for storm surge modeling is proposed. Currently numerical models exist that can resolve the details of coastal regions but are often too costly to be run in an ensemble forecasting framework without significant computing resources. The application of adaptive mesh refinement algorithms substantially lowers the computational cost of a storm surge model run while retaining much of the desired coastal resolution. The approach presented is implemented in the GeoClaw framework and compared to ADCIRC for Hurricane Ike along with observed tide gauge data and the computational cost of each model run. © 2014 Elsevier Ltd.

  6. Exploiting MeSH indexing in MEDLINE to generate a data set for word sense disambiguation

    Directory of Open Access Journals (Sweden)

    McInnes Bridget T

    2011-06-01

    Full Text Available Abstract Background Evaluation of Word Sense Disambiguation (WSD methods in the biomedical domain is difficult because the available resources are either too small or too focused on specific types of entities (e.g. diseases or genes. We present a method that can be used to automatically develop a WSD test collection using the Unified Medical Language System (UMLS Metathesaurus and the manual MeSH indexing of MEDLINE. We demonstrate the use of this method by developing such a data set, called MSH WSD. Methods In our method, the Metathesaurus is first screened to identify ambiguous terms whose possible senses consist of two or more MeSH headings. We then use each ambiguous term and its corresponding MeSH heading to extract MEDLINE citations where the term and only one of the MeSH headings co-occur. The term found in the MEDLINE citation is automatically assigned the UMLS CUI linked to the MeSH heading. Each instance has been assigned a UMLS Concept Unique Identifier (CUI. We compare the characteristics of the MSH WSD data set to the previously existing NLM WSD data set. Results The resulting MSH WSD data set consists of 106 ambiguous abbreviations, 88 ambiguous terms and 9 which are a combination of both, for a total of 203 ambiguous entities. For each ambiguous term/abbreviation, the data set contains a maximum of 100 instances per sense obtained from MEDLINE. We evaluated the reliability of the MSH WSD data set using existing knowledge-based methods and compared their performance to that of the results previously obtained by these algorithms on the pre-existing data set, NLM WSD. We show that the knowledge-based methods achieve different results but keep their relative performance except for the Journal Descriptor Indexing (JDI method, whose performance is below the other methods. Conclusions The MSH WSD data set allows the evaluation of WSD algorithms in the biomedical domain. Compared to previously existing data sets, MSH WSD contains a larger

  7. Exploiting MeSH indexing in MEDLINE to generate a data set for word sense disambiguation.

    Science.gov (United States)

    Jimeno-Yepes, Antonio J; McInnes, Bridget T; Aronson, Alan R

    2011-06-02

    Evaluation of Word Sense Disambiguation (WSD) methods in the biomedical domain is difficult because the available resources are either too small or too focused on specific types of entities (e.g. diseases or genes). We present a method that can be used to automatically develop a WSD test collection using the Unified Medical Language System (UMLS) Metathesaurus and the manual MeSH indexing of MEDLINE. We demonstrate the use of this method by developing such a data set, called MSH WSD. In our method, the Metathesaurus is first screened to identify ambiguous terms whose possible senses consist of two or more MeSH headings. We then use each ambiguous term and its corresponding MeSH heading to extract MEDLINE citations where the term and only one of the MeSH headings co-occur. The term found in the MEDLINE citation is automatically assigned the UMLS CUI linked to the MeSH heading. Each instance has been assigned a UMLS Concept Unique Identifier (CUI). We compare the characteristics of the MSH WSD data set to the previously existing NLM WSD data set. The resulting MSH WSD data set consists of 106 ambiguous abbreviations, 88 ambiguous terms and 9 which are a combination of both, for a total of 203 ambiguous entities. For each ambiguous term/abbreviation, the data set contains a maximum of 100 instances per sense obtained from MEDLINE.We evaluated the reliability of the MSH WSD data set using existing knowledge-based methods and compared their performance to that of the results previously obtained by these algorithms on the pre-existing data set, NLM WSD. We show that the knowledge-based methods achieve different results but keep their relative performance except for the Journal Descriptor Indexing (JDI) method, whose performance is below the other methods. The MSH WSD data set allows the evaluation of WSD algorithms in the biomedical domain. Compared to previously existing data sets, MSH WSD contains a larger number of biomedical terms/abbreviations and covers the largest

  8. Cache-mesh, a Dynamics Data Structure for Performance Optimization

    DEFF Research Database (Denmark)

    Nguyen, Tuan T.; Dahl, Vedrana Andersen; Bærentzen, J. Andreas

    2017-01-01

    This paper proposes the cache-mesh, a dynamic mesh data structure in 3D that allows modifications of stored topological relations effortlessly. The cache-mesh can adapt to arbitrary problems and provide fast retrieval to the most-referred-to topological relations. This adaptation requires trivial...... of the cache-mesh, and the extra work for caching is also trivial. Though it appears that it takes effort for initial implementation, building the cache-mesh is comparable to a traditional mesh in terms of implementation....

  9. Performance of the hybrid wireless mesh protocol for wireless mesh networks

    DEFF Research Database (Denmark)

    Boye, Magnus; Staalhagen, Lars

    2010-01-01

    Wireless mesh networks offer a new way of providing end-user access and deploying network infrastructure. Though mesh networks offer a price competitive solution to wired networks, they also come with a set of new challenges such as optimal path selection, channel utilization, and load balancing....... These challenges must first be overcome before satisfactory network stability and throughput can be achieved. This paper studies the performance of the Hybrid Wireless Mesh Protocol, the proposed routing protocol for the upcoming IEEE 802.11s standard. HWMP supports two modes of path selection: reactive...

  10. Anterior six arms prolene mesh for high stage vaginal prolapse: five years follow-up

    Directory of Open Access Journals (Sweden)

    Luis Gustavo M. de Toledo

    Full Text Available ABSTRACT Introduction In high stage vaginal prolapse, recurrence risk patients, anterior and apical defects need to be addressed in the same procedure. The pre-molded commercial mesh kits are expensive and not always available. Alternative effective and safe treatment ways, with lower costs are desirable. Objective To present long term follow-up of patients treated with a homemade mesh shape to correct high stage prolapses. Materials and Methods We describe prospectively 18 patients with anterior and apical vaginal prolapses, stages III and IV, repaired using this specific design of mesh. All patients were submitted to pre-operative clinical evaluation and urodynamics. Prolapse was classified using the pelvic organ prolapse quantification (POP-Q. Intervention Prolapse surgery, using a six arms prolene mesh, through a single anterior vaginal incision. Outcome Measurements: POP-Q, patients satisfaction, descriptive statistical analysis. Results Between February 2009 and Oct 2010, 18 consecutive women underwent the above-mentioned surgery. Mean age was 68 years. At a mean follow-up of .,4 years (5 to 5.8 years, 16 (89% patients were continent, mean Ba point came from +4.7cm to - 2.5cm, mean C point from +2.8cm to -6.6cm and mean Bp point from +1.3 to -1.7cm. There were two (11% objective failures, but all the patients were considered success subjectively. There were two cases of mesh vaginal extrusion. Conclusions The homemade six arms prolene mesh allows concomitant correction of anterior and apical prolapses, through a single anterior vaginal incision, being an effective, safe and affordable treatment option when mesh is needed.

  11. Prolene (mesh) bulbourethral sling in male incontinence

    OpenAIRE

    Rakesh Kapoor; Kamal Jeet Singh; Amit Suri; Pratipal Singh; Anil Mandhani

    2007-01-01

    Objective : We present our preliminary results of bulbar urethral sling (single bolster) in treatment of postprostatectomy urinary incontinence (PPUI). Materials and Methods: From May 2003 to June 2005, six patients with postprostatectomy urinary incontinence (transurethral resection of prostate in five patients and after open prostatectomy in one patient) underwent prolene mesh bulbar urethral sling surgery. Preoperative evaluation included physical examination, neurological assessment, str...

  12. Markov random fields on triangle meshes

    DEFF Research Database (Denmark)

    Andersen, Vedrana; Aanæs, Henrik; Bærentzen, Jakob Andreas

    2010-01-01

    In this paper we propose a novel anisotropic smoothing scheme based on Markov Random Fields (MRF). Our scheme is formulated as two coupled processes. A vertex process is used to smooth the mesh by displacing the vertices according to a MRF smoothness prior, while an independent edge process label...

  13. Markov Random Fields on Triangle Meshes

    DEFF Research Database (Denmark)

    Andersen, Vedrana; Aanæs, Henrik; Bærentzen, Jakob Andreas

    2010-01-01

    In this paper we propose a novel anisotropic smoothing scheme based on Markov Random Fields (MRF). Our scheme is formulated as two coupled processes. A vertex process is used to smooth the mesh by displacing the vertices according to a MRF smoothness prior, while an independent edge process label...

  14. Mid term outcome of robotic mesh sacrocolpopexy.

    Science.gov (United States)

    Belsante, Michael; Murray, Sunshine; Dillon, Benjamin; Zimmern, Philippe

    2013-02-01

    Use of robotic mesh sacrocolpopexy (RMS) has increased for management of pelvic organ prolapse (POP). We present our experience with mid term follow up. A retrospective chart review of consecutive patients who had RMS was performed. Patients underwent history and physical exam including POP-Q classification. In cases of bladder involvement a standing voiding cystourethrogram and urodynamics with vaginal pack reduction of the prolapse were done. Indication for RMS was patient preference, BMI vault prolapse. Three patients had secondary POP procedures. One patient developed a mesh erosion requiring surgical repair. Functional outcome improvement was noted with score reduction for QoL of 4.1 to 1.3 (p < 0.001), UDI-6 of 27.3 to 16.1 (p = 0.002), and IIQ-7 of 18.3 to 3.9 (p = 0.031). RMS performed reliably to correct symptomatic POP. The use of absorbable sutures to secure the mesh to the vaginal walls resulted in satisfactory anatomic outcomes and did not increase the risk of mesh erosion.

  15. Polypropylene mesh: evidence for lack of carcinogenicity

    Science.gov (United States)

    Moalli, Pamela; Brown, Bryan; Reitman, Maureen T. F.

    2016-01-01

    Tumors related to the implantation of surgical grade polypropylene in humans have never been reported. In this commentary we present a balanced review of the information on what is known regarding the host response to polypropylene and provide data as to why the potential for carcinogenicity of polypropylene mesh is exceedingly small. PMID:24614956

  16. Drag reduction properties of superhydrophobic mesh pipes

    Science.gov (United States)

    Geraldi, Nicasio R.; Dodd, Linzi E.; Xu, Ben B.; Wells, Gary G.; Wood, David; Newton, Michael I.; McHale, Glen

    2017-09-01

    Even with the recent extensive study into superhydrophobic surfaces, the fabrication of such surfaces on the inside walls of a pipe remains challenging. In this work we report a convenient bi-layered pipe design using a thin superhydrophobic metallic mesh formed into a tube, supported inside another pipe. A flow system was constructed to test the fabricated bi-layer pipeline, which allowed for different constant flow rates of water to be passed through the pipe, whilst the differential pressure was measured, from which the drag coefficient (ƒ) and Reynolds numbers (Re) were calculated. Expected values of ƒ were found for smooth glass pipes for the Reynolds number (Re) range 750-10 000, in both the laminar and part of the turbulent regimes. Flow through plain meshes without the superhydrophobic coating were also measured over a similar range (750  pipe of the same diameter. This demonstrates that a superhydrophobic mesh can support a plastron and provide a drag reduction compared to a plain mesh, however, the plastron is progressively destroyed with use and in particular at higher flow rates.

  17. [Implants for genital prolapse : Pro mesh surgery].

    Science.gov (United States)

    Neymeyer, J; Moldovan, D-E; Kornienko, K; Miller, K; Weichert, A

    2017-12-01

    There has been an overall increase in pelvic organ prolapse due to demographic changes (increased life expectancy). Increasing sociocultural demands of women require treatments that are more effective with methods that are more successful. In the treatment of pelvic floor insufficiency and uterovaginal prolapse, pelvic floor reconstructions with mesh implants have proven to be superior to conventional methods such as the classic colporrhaphy, reconstructions with biomaterial, and native tissue repair in appropriately selected patients and when applying exact operation techniques, especially because of good long-term results and low recurrence rates. When making a systematic therapy plan, one should adhere to certain steps, for example, a pelvic floor reconstruction should be undertaken before performing the corrective procedure for incontinence. The approach, if vaginal, laparoscopic, or abdominal should be chosen wisely, taking into consideration the required space of action, in such a way that none or only minimal collateral damage related to the operation occurs. The use of instrumental suturing techniques and operation robots are advantageous in the case of difficult approaches and limited anatomical spaces. In principle, the surgeon who implants meshes should be able to explant them! The surgical concept of mesh-related interventions in the pelvis must meet established rules. "Implant as little mesh as possible and only as much suitable (!) mesh as absolutely necessary!" In the case of apical direct fixations, a therapeutically relevant target variable is the elevation angle of vagina (EAV). Established anatomical fixation points are preferable. A safe distance between implants and vulnerable tissue is to be maintained. Mesh-based prolapse repairs are indicated in recurrences, in primary situations, in combined defects of the anterior compartment, in central defects of multimorbid and elderly patients, and above all, when organ preservation is wanted

  18. Jali - Unstructured Mesh Infrastructure for Multi-Physics Applications

    Energy Technology Data Exchange (ETDEWEB)

    2017-04-13

    Jali is a parallel unstructured mesh infrastructure library designed for use by multi-physics simulations. It supports 2D and 3D arbitrary polyhedral meshes distributed over hundreds to thousands of nodes. Jali can read write Exodus II meshes along with fields and sets on the mesh and support for other formats is partially implemented or is (https://github.com/MeshToolkit/MSTK), an open source general purpose unstructured mesh infrastructure library from Los Alamos National Laboratory. While it has been made to work with other mesh frameworks such as MOAB and STKmesh in the past, support for maintaining the interface to these frameworks has been suspended for now. Jali supports distributed as well as on-node parallelism. Support of on-node parallelism is through direct use of the the mesh in multi-threaded constructs or through the use of "tiles" which are submeshes or sub-partitions of a partition destined for a compute node.

  19. CUBIT mesh generation environment. Volume 1: Users manual

    Energy Technology Data Exchange (ETDEWEB)

    Blacker, T.D.; Bohnhoff, W.J.; Edwards, T.L. [and others

    1994-05-01

    The CUBIT mesh generation environment is a two- and three-dimensional finite element mesh generation tool which is being developed to pursue the goal of robust and unattended mesh generation--effectively automating the generation of quadrilateral and hexahedral elements. It is a solid-modeler based preprocessor that meshes volume and surface solid models for finite element analysis. A combination of techniques including paving, mapping, sweeping, and various other algorithms being developed are available for discretizing the geometry into a finite element mesh. CUBIT also features boundary layer meshing specifically designed for fluid flow problems. Boundary conditions can be applied to the mesh through the geometry and appropriate files for analysis generated. CUBIT is specifically designed to reduce the time required to create all-quadrilateral and all-hexahedral meshes. This manual is designed to serve as a reference and guide to creating finite element models in the CUBIT environment.

  20. Multi-terminology indexing for the assignment of MeSH descriptors to medical abstracts in French.

    Science.gov (United States)

    Pereira, Suzanne; Sakji, Saoussen; Névéol, Aurélie; Kergourlay, Ivan; Kerdelhué, Gaétan; Serrot, Elisabeth; Joubert, Michel; Darmoni, Stéfan J

    2009-11-14

    To facilitate information retrieval in the biomedical domain, a system for the automatic assignment of Medical Subject Headings to documents curated by an online quality-controlled health gateway was implemented. The French Multi-Terminology Indexer (F-MTI) implements a multiterminology approach using nine main medical terminologies in French and the mappings between them. This paper presents recent efforts to assess the added value of (a) integrating four new terminologies (Orphanet, ATC, drug names, MeSH supplementary concepts) into F-MTI's knowledge sources and (b) performing the automatic indexing on the titles and abstracts (vs. title only) of the online health resources. F-MTI was evaluated on a CISMeF corpus comprising 18,161 manually indexed resources. The performance of F-MTI including nine health terminologies on CISMeF resources with Title only was 27.9% precision and 19.7% recall, while the performance on CISMeF resources with Title and Abstract is 14.9 % precision (-13.0%) and 25.9% recall (+6.2%). In a few weeks, CISMeF will launch the indexing of resources based on title and abstract, using nine terminologies.

  1. On Reducing Delay in Mesh-Based P2P Streaming: A Mesh-Push Approach

    Science.gov (United States)

    Liu, Zheng; Xue, Kaiping; Hong, Peilin

    The peer-assisted streaming paradigm has been widely employed to distribute live video data on the internet recently. In general, the mesh-based pull approach is more robust and efficient than the tree-based push approach. However, pull protocol brings about longer streaming delay, which is caused by the handshaking process of advertising buffer map message, sending request message and scheduling of the data block. In this paper, we propose a new approach, mesh-push, to address this issue. Different from the traditional pull approach, mesh-push implements block scheduling algorithm at sender side, where the block transmission is initiated by the sender rather than by the receiver. We first formulate the optimal upload bandwidth utilization problem, then present the mesh-push approach, in which a token protocol is designed to avoid block redundancy; a min-cost flow model is employed to derive the optimal scheduling for the push peer; and a push peer selection algorithm is introduced to reduce control overhead. Finally, we evaluate mesh-push through simulation, the results of which show mesh-push outperforms the pull scheduling in streaming delay, and achieves comparable delivery ratio at the same time.

  2. Cryo-mesh: a simple alternative cryopreservation protocol.

    Science.gov (United States)

    Funnekotter, B; Bunn, E; Mancera, R L

    The continued development of new cryopreservation protocols has improved post-cryogenic success rates for a wide variety of plant species. Methods like the cryo-plate have proven beneficial in simplifying the cryopreservation procedure. This study assessed the practicality of a stainless steel mesh strip (cryo-mesh) for cryopreserving shoot tips from Anigozanthos viridis. Shoot tips of A. viridis (Kangaroo Paw) were precultured on 0.4 M sucrose medium for 48 h. Precultured shoot tips were coated in a 2% alginate solution and placed onto the cryo-mesh (a 25 x 7 mm, 0.4 mm aperture, 0.224 mm diameter wire stainless steel mesh strip). The alginate was set for 20 min in a loading solution containing 100 mM CaCl2, anchoring the shoot tips to the cryo-mesh. The cryo-mesh was then transferred to PVS2 on ice for 20, 30 or 40 min prior to plunging the cryo-mesh into liquid nitrogen. The cryo-mesh protocol was compared to the droplet-vitrification protocol. A maximum of 83% post-cryogenic regeneration was achieved with the cryo-mesh when exposed to PVS2 for 30 min. No significant difference in post-cryogenic regeneration was observed between the cryo-mesh and droplet-vitrification protocols. Anigozanthos viridis shoot tips were successfully cryopreserved utilising the new cryo-mesh. The cryo-mesh thus provides a simple and successful alternative for cryopreservation.

  3. Surgical Management of Pelvic floor Prolapse in women using Mesh

    African Journals Online (AJOL)

    RAH

    mesh. Methods: A retrospective review of patients who had pelvic floor repair using polypropylene mesh(PPM) and intra-vaginal sling(IVS), between January 2003 and July ... Conclusion: Polypropylene mesh (Prolene) is a simple effective method of treatment of pelvic floor .... erosion with sacrocolpopexy and concurrent.

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  5. Laparoscopic Total Extraperitoneal (TEP) Inguinal Hernia Repair Using 3-dimensional Mesh Without Mesh Fixation.

    Science.gov (United States)

    Aliyazicioglu, Tolga; Yalti, Tunc; Kabaoglu, Burcak

    2017-08-01

    Approximately one fifth of patients suffer from inguinal pain after laparoscopic total extraperitoneal (TEP) inguinal hernia repair. There is existing literature suggesting that the staples used to fix the mesh can cause postoperative inguinal pain. In this study, we describe our experience with laparoscopic TEP inguinal hernia surgery using 3-dimensional mesh without mesh fixation, in our institution. A total of 300 patients who had undergone laparoscopic TEP inguinal hernia repair with 3-dimensional mesh in VKV American Hospital, Istanbul from November 2006 to November 2015 were studied retrospectively. Using the hospital's electronic archive, we studied patients' selected parameters, which are demographic features (age, sex), body mass index, hernia locations and types, duration of operations, preoperative and postoperative complications, duration of hospital stays, cost of surgery, need for analgesics, time elapsed until returning to daily activities and work. A total of 300 patients underwent laparoscopic TEP hernia repair of 437 inguinal hernias from November 2006 to November 2015. Of the 185 patients, 140 were symptomatic. Mean duration of follow-up was 48 months (range, 6 to 104 mo). The mean duration of surgery was 55 minutes for bilateral hernia repair, and 38 minutes for unilateral hernia repair. The mean duration of hospital stay was 0.9 day. There was no conversion to open surgery. In none of the cases the mesh was fixated with either staples or fibrin glue. Six patients (2%) developed seroma that were treated conservatively. One patient had inguinal hernia recurrence. One patient had preperitoneal hematoma. One patient operated due to indirect right-sided hernia developed right-sided hydrocele. One patient had wound dehiscence at the umbilical port entry site. Chronic pain developed postoperatively in 1 patient. Ileus developed in 1 patient. Laparoscopic TEP inguinal repair with 3-dimensional mesh without mesh fixation can be performed as safe as

  6. Variational mesh segmentation via quadric surface fitting

    KAUST Repository

    Yan, Dongming

    2012-11-01

    We present a new variational method for mesh segmentation by fitting quadric surfaces. Each component of the resulting segmentation is represented by a general quadric surface (including plane as a special case). A novel energy function is defined to evaluate the quality of the segmentation, which combines both L2 and L2 ,1 metrics from a triangle to a quadric surface. The Lloyd iteration is used to minimize the energy function, which repeatedly interleaves between mesh partition and quadric surface fitting. We also integrate feature-based and simplification-based techniques in the segmentation framework, which greatly improve the performance. The advantages of our algorithm are demonstrated by comparing with the state-of-the-art methods. © 2012 Elsevier Ltd. All rights reserved.

  7. Adaptive upscaling with the dual mesh method

    Energy Technology Data Exchange (ETDEWEB)

    Guerillot, D.; Verdiere, S.

    1997-08-01

    The objective of this paper is to demonstrate that upscaling should be calculated during the flow simulation instead of trying to enhance the a priori upscaling methods. Hence, counter-examples are given to motivate our approach, the so-called Dual Mesh Method. The main steps of this numerical algorithm are recalled. Applications illustrate the necessity to consider different average relative permeability values depending on the direction in space. Moreover, these values could be different for the same average saturation. This proves that an a priori upscaling cannot be the answer even in homogeneous cases because of the {open_quotes}dynamical heterogeneity{close_quotes} created by the saturation profile. Other examples show the efficiency of the Dual Mesh Method applied to heterogeneous medium and to an actual field case in South America.

  8. Meshed split skin graft for extensive vitiligo

    Directory of Open Access Journals (Sweden)

    Srinivas C

    2004-05-01

    Full Text Available A 30 year old female presented with generalized stable vitiligo involving large areas of the body. Since large areas were to be treated it was decided to do meshed split skin graft. A phototoxic blister over recipient site was induced by applying 8 MOP solution followed by exposure to UVA. The split skin graft was harvested from donor area by Padgett dermatome which was meshed by an ampligreffe to increase the size of the graft by 4 times. Significant pigmentation of the depigmented skin was seen after 5 months. This procedure helps to cover large recipient areas, when pigmented donor skin is limited with minimal risk of scarring. Phototoxic blister enables easy separation of epidermis thus saving time required for dermabrasion from recipient site.

  9. Amplitudes of head movements during putative eye-only saccades.

    Science.gov (United States)

    Oommen, Brian S; Stahl, John S

    2005-12-14

    The mechanisms allowing humans and other primates to dissociate head and eye movements during saccades are poorly understood. A more precise knowledge of head movement behavior during apparent eye-only saccades may provide insight into those mechanisms. We studied the distributions of head amplitude in normal humans. In half of the subjects, these distributions indicated the presence of a population of minor ("residual") head movements during eye-only saccades, distinct from the continuum of head movements generated during frank eye-head saccades. Like full-sized head movements, the residual movements grew in proportion to target eccentricity, indicating their drive is derived from the premotor command for the saccade. Furthermore, their amplitudes related most strongly to the head amplitudes obtained when subjects produced full-sized head movements and were reduced when subjects were instructed to perform exclusively eye-only saccades. Both observations suggest that the drive for residual head movements originates downstream of the point in which the head movement command diverges from the generalized gaze shift command. The results are consistent with a model of head control in which a neural gate prevents the common gaze shift command from reaching the head premotor circuitry whenever an eye-only saccade is desired. However, the gate is either imperfect or the multiple pathways that relay gaze shift signals to the head motor circuitry allow for the gate to be circumvented. The results underscore the need for physiological studies to probe neuronal activity related to neck activation during eye-only saccades.

  10. Solid Mesh Registration for Radiotherapy Treatment Planning

    DEFF Research Database (Denmark)

    Noe, Karsten Østergaard; Sørensen, Thomas Sangild

    2010-01-01

    We present an algorithm for solid organ registration of pre-segmented data represented as tetrahedral meshes. Registration of the organ surface is driven by force terms based on a distance field representation of the source and reference shapes. Registration of internal morphology is achieved usi...... to complete. The proposed method has many potential uses in image guided radiotherapy (IGRT) which relies on registration to account for organ deformation between treatment sessions....

  11. On mesh rezoning algorithms for parallel platforms

    Energy Technology Data Exchange (ETDEWEB)

    Plaskacz, E.J.

    1995-07-01

    A mesh rezoning algorithm for finite element simulations in a parallel-distributed environment is described. The cornerstones of the algorithm are: the parallel computation of distortion norms on the element and subdomain level, the exchange of the individual subdomain norms to form a subdomain distortion vector, the classification of subdomains and the rezoning behavior prescribed within each subdomain as a response to its own classification and the classification of neighboring subdomains.

  12. Parallel local mesh refinement for Code Saturne

    OpenAIRE

    Tomas Karasek

    2014-01-01

    Computational Fluid Dynamics (CFD) is one of the eld which can fully utilize the capacity of existing HPC systems. There are many cases either from basic or applied research which are so complex that their numerical simulation with requested accuracy requires very ne representation of the computational domain. To solve certain problems numerical models consisting of hundred billions of cells are necessary. There are several approaches to create such huge meshes. One of them is bas...

  13. Head Impact Laboratory (HIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The HIL uses testing devices to evaluate vehicle interior energy attenuating (EA) technologies for mitigating head injuries resulting from head impacts during mine/...

  14. Collagen/Polypropylene composite mesh biocompatibility in abdominal wall reconstruction.

    Science.gov (United States)

    Lukasiewicz, Aleksander; Skopinska-Wisniewska, Joanna; Marszalek, Andrzej; Molski, Stanislaw; Drewa, Tomasz

    2013-05-01

    Intraperitoneal placement of polypropylene mesh leads to extensive visceral adhesions and is contraindicated. Different coatings are used to improve polypropylene mesh properties. Collagen is a protein with unique biocompatibility and cell ingrowth enhancement potential. A novel acetic acid extracted collagen coating was developed to allow placement of polypropylene mesh in direct contact with viscera. The authors' aim was to evaluate the long-term influence of acetic acid extracted collagen coating on surgical aspects and biomechanical properties of polypropylene mesh implanted in direct contact with viscera, including complications, adhesions with viscera, strength of incorporation, and microscopic inflammatory reaction. Forty adult Wistar rats were divided into two groups: experimental (polypropylene mesh/acetic acid extracted collagen coating) and control (polypropylene mesh only). Astandardized procedure of mesh implantation was performed. Animals were killed 3 months after surgery and analyzed for complications, mesh area covered by adhesions, type of adhesions, strength of incorporation, and intensity of inflammatory response. The mean adhesion area was lower for polypropylene mesh/acetic acid extracted collagen coating (14.5 percent versus 69.9 percent, p polypropylene mesh are significantly reduced because of acetic acid extracted collagen coating. The collagen coating does not increase complications or induce alterations of polypropylene mesh incorporation.

  15. MeSH Now: automatic MeSH indexing at PubMed scale via learning to rank.

    Science.gov (United States)

    Mao, Yuqing; Lu, Zhiyong

    2017-04-17

    MeSH indexing is the task of assigning relevant MeSH terms based on a manual reading of scholarly publications by human indexers. The task is highly important for improving literature retrieval and many other scientific investigations in biomedical research. Unfortunately, given its manual nature, the process of MeSH indexing is both time-consuming (new articles are not immediately indexed until 2 or 3 months later) and costly (approximately ten dollars per article). In response, automatic indexing by computers has been previously proposed and attempted but remains challenging. In order to advance the state of the art in automatic MeSH indexing, a community-wide shared task called BioASQ was recently organized. We propose MeSH Now, an integrated approach that first uses multiple strategies to generate a combined list of candidate MeSH terms for a target article. Through a novel learning-to-rank framework, MeSH Now then ranks the list of candidate terms based on their relevance to the target article. Finally, MeSH Now selects the highest-ranked MeSH terms via a post-processing module. We assessed MeSH Now on two separate benchmarking datasets using traditional precision, recall and F 1 -score metrics. In both evaluations, MeSH Now consistently achieved over 0.60 in F-score, ranging from 0.610 to 0.612. Furthermore, additional experiments show that MeSH Now can be optimized by parallel computing in order to process MEDLINE documents on a large scale. We conclude that MeSH Now is a robust approach with state-of-the-art performance for automatic MeSH indexing and that MeSH Now is capable of processing PubMed scale documents within a reasonable time frame. http://www.ncbi.nlm.nih.gov/CBBresearch/Lu/Demo/MeSHNow/ .

  16. A Triangle Mesh Standardization Method Based on Particle Swarm Optimization.

    Science.gov (United States)

    Wang, Wuli; Duan, Liming; Bai, Yang; Wang, Haoyu; Shao, Hui; Zhong, Siyang

    2016-01-01

    To enhance the triangle quality of a reconstructed triangle mesh, a novel triangle mesh standardization method based on particle swarm optimization (PSO) is proposed. First, each vertex of the mesh and its first order vertices are fitted to a cubic curve surface by using least square method. Additionally, based on the condition that the local fitted surface is the searching region of PSO and the best average quality of the local triangles is the goal, the vertex position of the mesh is regulated. Finally, the threshold of the normal angle between the original vertex and regulated vertex is used to determine whether the vertex needs to be adjusted to preserve the detailed features of the mesh. Compared with existing methods, experimental results show that the proposed method can effectively improve the triangle quality of the mesh while preserving the geometric features and details of the original mesh.

  17. Data-Parallel Mesh Connected Components Labeling and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Cyrus; Childs, Hank; Gaither, Kelly

    2011-04-10

    We present a data-parallel algorithm for identifying and labeling the connected sub-meshes within a domain-decomposed 3D mesh. The identification task is challenging in a distributed-memory parallel setting because connectivity is transitive and the cells composing each sub-mesh may span many or all processors. Our algorithm employs a multi-stage application of the Union-find algorithm and a spatial partitioning scheme to efficiently merge information across processors and produce a global labeling of connected sub-meshes. Marking each vertex with its corresponding sub-mesh label allows us to isolate mesh features based on topology, enabling new analysis capabilities. We briefly discuss two specific applications of the algorithm and present results from a weak scaling study. We demonstrate the algorithm at concurrency levels up to 2197 cores and analyze meshes containing up to 68 billion cells.

  18. Efficacy and pregnancy outcomes of laparoscopic single sheet mesh sacrohysteropexy.

    Science.gov (United States)

    Pandeva, Ivilina; Mistry, Minesh; Fayyad, Abdalla

    2017-03-01

    To evaluate outcomes following laparoscopic single sheet mesh sacrohysteropexy for the management of uterine prolapse. One hundred and fifty-nine women underwent the procedure between August 2010 and August 2014. One hundred and forty-four patients completed the follow up assessment. At each visit, the prolapse symptoms were assessed using the prolapse quality-of-life (P-QOL) questionnaire and objectively with the use of the Pelvic Organ Prolapse Quantification (POPQ) score. The subjective outcomes were also evaluated with the use of the Patient Global Impression of Improvement (PGII) questionnaires. Perioperative complications and further surgery for prolapse were evaluated. Women who conceived following the procedure were evaluated for pregnancy outcomes and prolapse recurrence. Pre-operatively, 85% (135/159) had uterine prolapse ≥ stage 2. Postoperatively, 95.1% (137/144) of women had anatomical success rate defined as stage 0 uterine descent. Eighty-two percent (118/144) of women reported cure of prolapse symptoms and feeling "much better" or "very much better" on postoperative PGII assessment. Eight women (5%) became pregnant following the laparoscopic sacrohysteropexy- seven had full term pregnancies and one had a miscarriage. Six out of the seven (86%) had stage 0 apical prolapse and PGII of "much better" at 6 months postpartum. One patient had symptomatic prolapse recurrence and underwent perineorrhaphy at 3 years. Laparoscopic single sheet mesh sacrohysteropexy is associated with subjective and objective improvement in prolapse symptoms and QoL that is maintained up to 48 months. Laparoscopic sacrohysteropexy can be offered to women desiring future fertility; however, further research is needed to advise on best surgical approach in women of childbearing age. Neurourol. Urodynam. 36:787-793, 2017. © 2016 The Authors. Neurourology and Urodynamics Published by Wiley Periodicals, Inc. © 2016 The Authors. Neurourology and Urodynamics Published by Wiley

  19. Individual prefabricated titanium implants and titanium mesh in skull base reconstructive surgery. A report of cases.

    Science.gov (United States)

    Schipper, J; Ridder, G J; Spetzger, U; Teszler, C B; Fradis, M; Maier, W

    2004-05-01

    Titanium implants can be shaped by traditional hand forming, press shaping, modular construction by welding, construction on full-size models shaped from CT coordinates and, most recently, by computer-assisted design and computer-assisted manufacturing (CAD/CAM) that consist in the direct prefabrication of individual implants by milling them out of a solid block of titanium. The aim of our study was to present a set of preliminary cases of an ongoing program of reconstructive procedures of the skull base using titanium implants. The subjects underwent ablative procedures of the skull base with reconstruction either by titanium mesh or individual prefabricated CAD/CAM implants. Six patients have been operated on successfully since 2000: two received prefabricated CAD/CAM titanium plates and four others underwent reconstruction with titanium mesh. The stability of CAD/CAM plates is superior to that of mesh, thus it is more useful in reconstructing large lesions of the frontal skull base and the temporal and occipital bones. Titanium mesh was successfully used for defects smaller than 100 cm(2) or where selected viscerocranial defects are complicated in design and less reproducible by CAD/CAM. The intraoperative design, shaping and adjustment characteristic of titanium mesh can be dispensed with when CAD/CAM implants are used. The 3-D data set used in the CAD/CAM process also operates in the navigated simulation and planning of the ablation contours, the latter being of great assistance in establishing the optimal future defect. As a disadvantage, CAD/CAM technology is more expensive than titanium mesh, and the process is time-consuming as it is carried out in advance of surgery.

  20. Bioactive cell-derived matrices combined with polymer mesh scaffold for osteogenesis and bone healing.

    Science.gov (United States)

    Kim, In Gul; Hwang, Mintai P; Du, Ping; Ko, Jaehoon; Ha, Chul-won; Do, Sun Hee; Park, Kwideok

    2015-05-01

    Successful bone tissue engineering generally requires an osteoconductive scaffold that consists of extracellular matrix (ECM) to mimic the natural environment. In this study, we developed a PLGA/PLA-based mesh scaffold coated with cell-derived extracellular matrix (CDM) for the delivery of bone morphogenic protein (BMP-2), and assessed the capacity of this system to provide an osteogenic microenvironment. Decellularized ECM from human lung fibroblasts (hFDM) was coated onto the surface of the polymer mesh scaffolds, upon which heparin was then conjugated onto hFDM via EDC chemistry. BMP-2 was subsequently immobilized onto the mesh scaffolds via heparin, and released at a controlled rate. Human placenta-derived mesenchymal stem cells (hPMSCs) were cultured in such scaffolds and subjected to osteogenic differentiation for 28 days in vitro. The results showed that alkaline phosphatase (ALP) activity, mineralization, and osteogenic marker expression were significantly improved with hPMSCs cultured in the hFDM-coated mesh scaffolds compared to the control and fibronectin-coated ones. In addition, a mouse ectopic and rat calvarial bone defect model was used to examine the feasibility of current platform to induce osteogenesis as well as bone regeneration. All hFDM-coated mesh groups exhibited a significant increase of newly formed bone and in particular, hFDM-coated mesh scaffold loaded with a high dose of BMP-2 exhibited a nearly complete bone defect healing as confirmed via micro-CT and histological observation. This work proposes a great potency of using hFDM (biophysical) coupled with BMP-2 (biochemical) as a promising osteogenic microenvironment for bone tissue engineering applications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Comparative analysis of autodermal graft and polypropylene mesh use in large incisional hernia defects reconstruction

    Directory of Open Access Journals (Sweden)

    Stojiljković Danilo

    2013-01-01

    Full Text Available Background. Large defects of the abdominal wall caused by incisional hernia still represent a challenging problem in plastic, reconstructive, and abdominal surgery. For their successful tension-free repair a proper selection of reconstructive material is essential. In the last decades, the use of synthetic meshes was dominant while biological autodermal grafts were rarely used. The aim of the study was to comparatively analyse efficacy and safety of autodermal graft and polypropylene mesh in surgical treatment of large abdominal wall defects. Methods. This prospective comparative clinical study enroled 40 patients surgically treated for large incisional hernia repair in a 10-year period. The patients were divided into two equal groups consisting of 20 subjects and treated either by biological autodermal graft or by synthetic polypropylene mesh. The surgical techniques of reconstruction, duration of surgery, the occurrence of early, minor, and major (severe and delyed complications and hospital stay were analyzed. The average follow-up took 2 years. Results. Statistically significant differences in demographic characteristics of patients and in size of defects were not found. The surgical technique of reconstruction with an autodermal graft was more complicated. The duration of surgery in patients treated with autodermal grafts was significantly longer. There was no statistically significant difference regarding occurrence of early, minor postoperative complications and hospital stay in our study. Two severe complications were registered in the synthetic mesh group: intestinal obstruction and enterocutaneous fistula. The recurrence rate was 10% in the autodermal graft group and 15% in the group with a synthetic mesh. Conclusion. Tension-free repair of large incisional hernia with autodermal grafts was unjustly neglected despite the fact that it is safe and effective. It can be applied in all cases where synthetic mesh are not indicated (presence

  2. Effects of Ultraviolet Photofunctionalization on Bone Augmentation and Integration Capabilities of Titanium Mesh and Implants.

    Science.gov (United States)

    Hirota, Makoto; Ikeda, Takayuki; Tabuchi, Masako; Ozawa, Tomomichi; Tohnai, Iwai; Ogawa, Takahiro

    Ultraviolet (UV)-mediated photofunctionalization has earned considerable attention for the enhancement of the biologic capabilities of titanium. The effects of photofunctionalization on bone augmentation and gap closure were examined using titanium implants and mesh in a rat femur model. An acid-etched titanium implant (4-mm length, 1-mm diameter) was placed in the gluteal tuberosity that resembles a knife-edge-like edentulous ridge. The lower half of the implant was located in a 2-mm-diameter defect created in the bone without cortical bone support; the upper half was exposed and covered with a titanium mesh to provide augmentation space. After 12 and 24 days of healing, specimens were subjected to microcomputed tomography (micro-CT)- and histology-based bone morphometry in three zones of analysis: augmentation, cortical bone-implant gap, and bone marrow. A biomechanical push-in test was performed to examine the strength of bone-implant integration. Photofunctionalization was performed by treating titanium implants and mesh with UV light for 12 minutes. Photofunctionalized titanium mesh and implants were hydrophilic, whereas untreated controls were hydrophobic. Bone volume was significantly greater in photofunctionalized implants and mesh than in untreated implants in all zones on days 12 and 24. Bone-to-implant contact of photofunctionalized implants was greater than that of untreated implants, not just in the bone marrow but also in the gap and augmented zones. The strength of osseointegration was three times greater for photofunctionalized implants than for untreated implants. Use of photofunctionalized titanium mesh and implants effectively enhanced vertical bone augmentation, cortical bone-implant gap closure, and osseointegration without innate bone support.

  3. Oral, intestinal, and skin bacteria in ventral hernia mesh implants

    Directory of Open Access Journals (Sweden)

    Odd Langbach

    2016-07-01

    Full Text Available Background: In ventral hernia surgery, mesh implants are used to reduce recurrence. Infection after mesh implantation can be a problem and rates around 6–10% have been reported. Bacterial colonization of mesh implants in patients without clinical signs of infection has not been thoroughly investigated. Molecular techniques have proven effective in demonstrating bacterial diversity in various environments and are able to identify bacteria on a gene-specific level. Objective: The purpose of this study was to detect bacterial biofilm in mesh implants, analyze its bacterial diversity, and look for possible resemblance with bacterial biofilm from the periodontal pocket. Methods: Thirty patients referred to our hospital for recurrence after former ventral hernia mesh repair, were examined for periodontitis in advance of new surgical hernia repair. Oral examination included periapical radiographs, periodontal probing, and subgingival plaque collection. A piece of mesh (1×1 cm from the abdominal wall was harvested during the new surgical hernia repair and analyzed for bacteria by PCR and 16S rRNA gene sequencing. From patients with positive PCR mesh samples, subgingival plaque samples were analyzed with the same techniques. Results: A great variety of taxa were detected in 20 (66.7% mesh samples, including typical oral commensals and periodontopathogens, enterics, and skin bacteria. Mesh and periodontal bacteria were further analyzed for similarity in 16S rRNA gene sequences. In 17 sequences, the level of resemblance between mesh and subgingival bacterial colonization was 98–100% suggesting, but not proving, a transfer of oral bacteria to the mesh. Conclusion: The results show great bacterial diversity on mesh implants from the anterior abdominal wall including oral commensals and periodontopathogens. Mesh can be reached by bacteria in several ways including hematogenous spread from an oral site. However, other sites such as gut and skin may also

  4. Integration of Mesh Optimization with 3D All-Hex Mesh Generation, LDRD Subcase 3504340000, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    KNUPP,PATRICK; MITCHELL,SCOTT A.

    1999-11-01

    In an attempt to automatically produce high-quality all-hex meshes, we investigated a mesh improvement strategy: given an initial poor-quality all-hex mesh, we iteratively changed the element connectivity, adding and deleting elements and nodes, and optimized the node positions. We found a set of hex reconnection primitives. We improved the optimization algorithms so they can untangle a negative-Jacobian mesh, even considering Jacobians on the boundary, and subsequently optimize the condition number of elements in an untangled mesh. However, even after applying both the primitives and optimization we were unable to produce high-quality meshes in certain regions. Our experiences suggest that many boundary configurations of quadrilaterals admit no hexahedral mesh with positive Jacobians, although we have no proof of this.

  5. A THREE-YEAR EXPERIENCE WITH ANTERIOR TRANSOBTURATOR MESH (ATOM AND POSTERIOR ISCHIORECTAL MESH (PIRM

    Directory of Open Access Journals (Sweden)

    Marijan Lužnik

    2018-02-01

    Full Text Available Background. Use of alloplastic mesh implantates allow a new urogynecologycal surgical techniques achieve a marked improvement in pelvic organ static and pelvic floor function with minimally invasive needle transvaginal intervention like an anterior transobturator mesh (ATOM and a posterior ischiorectal mesh (PIRM procedures. Methods. In three years, between April 2006 and May 2009, we performed one hundred and eightyfour operative corrections of female pelvic organ prolapse (POP and pelvic floor dysfunction (PFD with mesh implantates. The eighty-three patients with surgical procedure TVT-O or Monarc as solo intervention indicated by stress urinary incontinence without POP, are not included in this number. In 97 % of mesh operations, Gynemesh 10 × 15 cm was used. For correction of anterior vaginal prolapse with ATOM procedure, Gynemesh was individually trimmed in mesh with 6 free arms for tension-free transobturator application and tension-free apical collar. IVS (Intravaginal sling 04 Tunneller (Tyco needle system was used for transobturator application of 6 arms through 4 dermal incisions (2 on right and 2 on left. Minimal anterior median colpotomy was made in two separate parts. For correction of posterior vaginal prolapse with PIRM procedure Gynemesh was trimmed in mesh with 4 free arms and tension-free collar. Two ischiorectal long arms for tension-free application through fossa ischiorectale – right and left, and two short arms for perineal body also on both sides. IVS 02 Tunneller (Tyco needle system was used for tension-free application of 4 arms through 4 dermal incisions (2 on right and 2 on left in PIRM. Results. All 184 procedures were performed relatively safely. In 9 cases of ATOM we had perforation of bladder, in 5 by application of anterior needle, in 3 by application of posterior needle and in one case with pincette when collar was inserted in lateral vesico – vaginal space. In 2 cases of PIRM we had perforation of rectum

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  7. Systematic analysis of head-to-head gene organization: evolutionary conservation and potential biological relevance.

    Directory of Open Access Journals (Sweden)

    Yuan-Yuan Li

    2006-07-01

    Full Text Available Several "head-to-head" (or "bidirectional" gene pairs have been studied in individual experiments, but genome-wide analysis of this gene organization, especially in terms of transcriptional correlation and functional association, is still insufficient. We conducted a systematic investigation of head-to-head gene organization focusing on structural features, evolutionary conservation, expression correlation and functional association. Of the present 1,262, 1,071, and 491 head-to-head pairs identified in human, mouse, and rat genomes, respectively, pairs with 1- to 400-base pair distance between transcription start sites form the majority (62.36%, 64.15%, and 55.19% for human, mouse, and rat,respectively of each dataset, and the largest group is always the one with a transcription start site distance of 101 to 200 base pairs. The phylogenetic analysis among Fugu, chicken, and human indicates a negative selection on the separation of head-to-head genes across vertebrate evolution, and thus the ancestral existence of this gene organization. The expression analysis shows that most of the human head-to-head genes are significantly correlated,and the correlation could be positive, negative, or alternative depending on the experimental conditions. Finally, head to-head genes statistically tend to perform similar functions, and gene pairs associated with the significant cofunctions seem to have stronger expression correlations. The findings indicate that the head-to-head gene organization is ancient and conserved, which subjects functionally related genes to correlated transcriptional regulation and thus provides an exquisite mechanism of transcriptional regulation based on gene organization. These results have significantly expanded the knowledge about head-to-head gene organization. Supplementary materials for this study are available at http://www.scbit.org/h2h.

  8. [Meta-Mesh: metagenomic data analysis system].

    Science.gov (United States)

    Su, Xiaoquan; Song, Baoxing; Wang, Xuetao; Ma, Xinle; Xu, Jian; Ning, Kang

    2014-01-01

    With the current accumulation of metagenome data, it is possible to build an integrated platform for processing of rigorously selected metagenomic samples (also referred as "metagenomic communities" here) of interests. Any metagenomic samples could then be searched against this database to find the most similar sample(s). However, on one hand, current databases with a large number of metagenomic samples mostly serve as data repositories but not well annotated database, and only offer few functions for analysis. On the other hand, the few available methods to measure the similarity of metagenomic data could only compare a few pre-defined set of metagenome. It has long been intriguing scientists to effectively calculate similarities between microbial communities in a large repository, to examine how similar these samples are and to find the correlation of the meta-information of these samples. In this work we propose a novel system, Meta-Mesh, which includes a metagenomic database and its companion analysis platform that could systematically and efficiently analyze, compare and search similar metagenomic samples. In the database part, we have collected more than 7 000 high quality and well annotated metagenomic samples from the public domain and in-house facilities. The analysis platform supplies a list of online tools which could accept metagenomic samples, build taxonomical annotations, compare sample in multiple angle, and then search for similar samples against its database by a fast indexing strategy and scoring function. We also used case studies of "database search for identification" and "samples clustering based on similarity matrix" using human-associated habitat samples to demonstrate the performance of Meta-Mesh in metagenomic analysis. Therefore, Meta-Mesh would serve as a database and data analysis system to quickly parse and identify similar

  9. 3D Compressible Melt Transport with Adaptive Mesh Refinement

    Science.gov (United States)

    Dannberg, Juliane; Heister, Timo

    2015-04-01

    Melt generation and migration have been the subject of numerous investigations, but their typical time and length-scales are vastly different from mantle convection, which makes it difficult to study these processes in a unified framework. The equations that describe coupled Stokes-Darcy flow have been derived a long time ago and they have been successfully implemented and applied in numerical models (Keller et al., 2013). However, modelling magma dynamics poses the challenge of highly non-linear and spatially variable material properties, in particular the viscosity. Applying adaptive mesh refinement to this type of problems is particularly advantageous, as the resolution can be increased in mesh cells where melt is present and viscosity gradients are high, whereas a lower resolution is sufficient in regions without melt. In addition, previous models neglect the compressibility of both the solid and the fluid phase. However, experiments have shown that the melt density change from the depth of melt generation to the surface leads to a volume increase of up to 20%. Considering these volume changes in both phases also ensures self-consistency of models that strive to link melt generation to processes in the deeper mantle, where the compressibility of the solid phase becomes more important. We describe our extension of the finite-element mantle convection code ASPECT (Kronbichler et al., 2012) that allows for solving additional equations describing the behaviour of silicate melt percolating through and interacting with a viscously deforming host rock. We use the original compressible formulation of the McKenzie equations, augmented by an equation for the conservation of energy. This approach includes both melt migration and melt generation with the accompanying latent heat effects. We evaluate the functionality and potential of this method using a series of simple model setups and benchmarks, comparing results of the compressible and incompressible formulation and

  10. A NOVEL METHOD FOR ANALYZING ELECTRIC FIELD DISTRIBUTION OF ELECTRO CAPACITIVE CANCER TREATMENT (ECCT USING WIRE MESH ELECTRODES: A CASE STUDY OF BRAIN CANCER THERAPY.

    Directory of Open Access Journals (Sweden)

    Linahtadiya Andiani

    2017-12-01

    Full Text Available Electric field distribution analysis generated by ECCT in a human head model with or without brain cancer using wire mesh electrode has been conductedsuccessfully. The analysis of electric field distribution was done using simulation in a human head model with ECCT Apparel Helmet system type A which is three dimensional model. The electric field distribution was measured with and without a wire mesh electrode which was either passive or active using COMSOL Multiphysics 5.2 software and was then processed using MATLAB R2010a. The aim of the research was to assess the performance of wire mesh electrode in detecting electric field distribution. ECCT which is utilized in brain cancer therapy with input 10 V is able to produce an electric field with an average of 178.8 V/m. The input voltage influences electric field distribution whereas the signal frequency does not affect the electric field distribution. Wire mesh electrode which is either active or passive can measure the electric field distribution generated by ECCT that neither the active nor the passive wire mesh electrode changed the pattern of the electric field distribution and the change in the measured electric field value is not significant.

  11. MEDIT : An interactive Mesh visualization Software

    OpenAIRE

    Frey, Pascal

    2001-01-01

    This technical report describes the main features of MEDIT (This software wa registered with the APP under n° IDDN.FR.001.410023.00.R.P. 2001.000.10800 on january 25, 2001.), an interactive mesh visualization tool developped in the Gamma project at INRIA-Rocquencourt. Based on the graphic standard OpenGL, this software has been specifically designed to fulfill most of the common requirements of engineers and numericians, in the context of numerical simulations. This program is rather intuitiv...

  12. Unbiased sampling and meshing of isosurfaces

    KAUST Repository

    Yan, Dongming

    2014-11-01

    In this paper, we present a new technique to generate unbiased samples on isosurfaces. An isosurface, F(x,y,z) = c , of a function, F , is implicitly defined by trilinear interpolation of background grid points. The key idea of our approach is that of treating the isosurface within a grid cell as a graph (height) function in one of the three coordinate axis directions, restricted to where the slope is not too high, and integrating / sampling from each of these three. We use this unbiased sampling algorithm for applications in Monte Carlo integration, Poisson-disk sampling, and isosurface meshing.

  13. Corset neophallic musculoplasty with a mesh endoprosthesis

    Directory of Open Access Journals (Sweden)

    V. V. Mikhailichenko

    2014-01-01

    Full Text Available During thoracodorsal flap phalloplasty, recovered contractility of the muscular base of the neophallus may lead to its shortening that impedes introjection.To eliminate deformity and shortening of the neophallus, the authors propose the procedure of corset plasty of its muscle, which differs in that the alloplastic material – esfil mesh endoprosthesis, is used as a corset instead of fascia latum of the hip. The proposed procedure reduces surgical trauma, improves the functional characteristics of the neophallus, and accelerates sexual rehabilitation.

  14. Corset neophallic musculoplasty with a mesh endoprosthesis

    Directory of Open Access Journals (Sweden)

    V. V. Mikhailichenko

    2014-12-01

    Full Text Available During thoracodorsal flap phalloplasty, recovered contractility of the muscular base of the neophallus may lead to its shortening that impedes introjection.To eliminate deformity and shortening of the neophallus, the authors propose the procedure of corset plasty of its muscle, which differs in that the alloplastic material – esfil mesh endoprosthesis, is used as a corset instead of fascia latum of the hip. The proposed procedure reduces surgical trauma, improves the functional characteristics of the neophallus, and accelerates sexual rehabilitation.

  15. Performance of FACTS equipment in Meshed systems

    Energy Technology Data Exchange (ETDEWEB)

    Lerch, E.; Povh, D. [Siemens AG, Berlin (Germany)

    1994-12-31

    Modern power electronic devices such as thyristors and GTOs have made it possible to design controllable network elements, which will play a considerable role in ensuring reliable economic operation of transmission systems as a result of their capability to rapidly change active and reactive power. A number of FACTS elements for high-speed active and reactive power control will be described. Control of power system fluctuations in meshed systems by modulation of active and reactive power will be demonstrated using a number of examples. (author) 7 refs., 11 figs.

  16. A Fast and Scalable Algorithm for Calculating the Achievable Capacity of a Wireless Mesh Network

    Science.gov (United States)

    2016-05-09

    J. Welsh and M. B. Powell, “An upper bound for the chromatic number of a graph and its application to timetabling problems ,” The Computer Journal... problem of rapidly deter- mining the maximum achievable capacity of a multi-hop wireless mesh network subject to interference constraints. Being able to...deployed networks. The joint routing and scheduling problem for a given set of demands is an NP-Hard cross-layer optimization problem [4], and just finding

  17. Reliability and validity of food portion size estimation from images using manual flexible digital virtual meshes.

    Science.gov (United States)

    Beltran, Alicia; Dadabhoy, Hafza; Ryan, Courtney; Dholakia, Ruchita; Baranowski, Janice; Li, Yuecheng; Yan, Guifang; Jia, Wenyan; Sun, Mingui; Baranowski, Tom

    2018-02-12

    The eButton takes frontal images at 4s intervals throughout the day. A three-dimensional manually administered wire mesh procedure has been developed to quantify portion sizes from the two-dimensional images. The present paper reports a test of the inter-rater reliability and validity of use of the wire mesh procedure. Seventeen foods of diverse shapes and sizes served on plates, bowls and cups were selected to rigorously test the portion assessment procedure. A dietitian not involved in inter-rater reliability assessment used standard cups to independently measure the quantities of foods to generate the 'true' value for a total of seventy-five 'served' and seventy-five smaller 'left' images with diverse portion sizes. The images appeared on the computer to which the digital wire meshes were applied. Two dietitians and three engineers independently estimated portion size of the larger ('served') and smaller ('left') images for the same foods. The engineers had higher reliability and validity than the dietitians. The dietitians had lower reliabilities and validities for the smaller more irregular images, but the engineers did not, suggesting training could overcome this limitation. The lower reliabilities and validities for foods served in bowls, compared with plates, suggest difficulties with the curved nature of the bowls. The wire mesh procedure is an important step forward in quantifying portion size, which has been subject to substantial self-report error. Improved training procedures are needed to overcome the identified problems.

  18. Rarefied gas flows through meshes and implications for atmospheric measurements

    Directory of Open Access Journals (Sweden)

    J. Gumbel

    Full Text Available Meshes are commonly used as part of instruments for in situ atmospheric measurements. This study analyses the aerodynamic effect of meshes by means of wind tunnel experiments and numerical simulations. Based on the Direct Simulation Monte Carlo method, a simple mesh parameterisation is described and applied to a number of representative flow conditions. For open meshes freely exposed to the flow, substantial compression effects are found both upstream and downstream of the mesh. Meshes attached to close instrument structures, on the other hand, cause only minor flow disturbances. In an accompanying paper, the approach developed here is applied to the quantitative analysis of rocket-borne density measurements in the middle atmosphere.

    Key words. Atmospheric composition and structure (instruments and techniques; middle atmosphere – composition and chemistry

  19. Fire performance of basalt FRP mesh reinforced HPC thin plates

    DEFF Research Database (Denmark)

    Hulin, Thomas; Hodicky, Kamil; Schmidt, Jacob Wittrup

    2013-01-01

    An experimental program was carried out to investigate the influence of basalt FRP (BFRP) reinforcing mesh on the fire behaviour of thin high performance concrete (HPC) plates applied to sandwich elements. Samples with BFRP mesh were compared to samples with no mesh, samples with steel mesh...... on a linear increase of the volume of melted epoxy and the outflow of moisture from the concrete matrix. It was concluded that the use of a BFRP mesh to reinforce HPC exposed to fire reduces the mechanical strength despite a beneficial effect related to spalling....... and samples displaying a full sandwich structure. Final results confirmed the bond loss between concrete and BFRP mesh with temperature. The available void where the epoxy burnt away allowed the concrete matrix to release pressure and limit pore stresses, delaying spalling. It also reduced the mechanical...

  20. Tetrahedral Mesh Improvement Using Multi-face Retriangulation

    DEFF Research Database (Denmark)

    Misztal, Marek Krzysztof; Bærentzen, Jakob Andreas; Anton, Francois

    2009-01-01

    the algorithm is completely general with regard to quality criterion, we target improvement of the dihedral angle. The central idea in our algorithm is the introduction of a new local operation called multi-face retriangulation (MFRT) which supplements other known local operations. Like in many previous papers......In this paper we propose a simple technique for tetrahedral mesh improvement without inserting Steiner vertices, concentrating mainly on boundary conforming meshes. The algorithm makes local changes to the mesh to remove tetrahedra which are poor according to some quality criterion. While...... on tetrahedral mesh improvement, our algorithm makes local changes to the mesh to reduce an energy measure which reflects the quality criterion. The addition of our new local operation allows us to advance the mesh to a lower energy state in cases where no other local change would lead to a reduction. We also...

  1. Moving mesh generation with a sequential approach for solving PDEs

    DEFF Research Database (Denmark)

    of physical and mesh equations suffers typically from long computation time due to highly nonlinear coupling between the two equations. Moreover, the extended system (physical and mesh equations) may be sensitive to the tuning parameters such as a temporal relaxation factor. It is therefore useful to design...... generation and solution interpolation). Convection terms, which appear in physical PDEs and a mesh equation, are discretized by a WENO (Weighted Essentially Non-Oscillatory) scheme under the consrvative form. This sequential approach is to keep the advantages of robustness and simplicity for the static......In moving mesh methods, physical PDEs and a mesh equation derived from equidistribution of an error metrics (so-called the monitor function) are simultaneously solved and meshes are dynamically concentrated on steep regions (Lim et al., 2001). However, the simultaneous solution procedure...

  2. Image-Based Geometric Modeling and Mesh Generation

    CERN Document Server

    2013-01-01

    As a new interdisciplinary research area, “image-based geometric modeling and mesh generation” integrates image processing, geometric modeling and mesh generation with finite element method (FEM) to solve problems in computational biomedicine, materials sciences and engineering. It is well known that FEM is currently well-developed and efficient, but mesh generation for complex geometries (e.g., the human body) still takes about 80% of the total analysis time and is the major obstacle to reduce the total computation time. It is mainly because none of the traditional approaches is sufficient to effectively construct finite element meshes for arbitrarily complicated domains, and generally a great deal of manual interaction is involved in mesh generation. This contributed volume, the first for such an interdisciplinary topic, collects the latest research by experts in this area. These papers cover a broad range of topics, including medical imaging, image alignment and segmentation, image-to-mesh conversion,...

  3. Comparative study of ppen mesh repair and Desarda's no-mesh ...

    African Journals Online (AJOL)

    Background: The first author has described a new technique of pure tissue hernia repair and published his results previously1,2. This article describes the results of a comparative study of this new technique and the open mesh repair done in a district level general hospital set up in India. Methods: This is a retrospective ...

  4. Dynamic Mesh Adaptation for Front Evolution Using Discontinuous Galerkin Based Weighted Condition Number Mesh Relaxation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, Patrick T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Schofield, Samuel P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Nourgaliev, Robert [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-06-21

    A new mesh smoothing method designed to cluster mesh cells near a dynamically evolving interface is presented. The method is based on weighted condition number mesh relaxation with the weight function being computed from a level set representation of the interface. The weight function is expressed as a Taylor series based discontinuous Galerkin projection, which makes the computation of the derivatives of the weight function needed during the condition number optimization process a trivial matter. For cases when a level set is not available, a fast method for generating a low-order level set from discrete cell-centered elds, such as a volume fraction or index function, is provided. Results show that the low-order level set works equally well for the weight function as the actual level set. Meshes generated for a number of interface geometries are presented, including cases with multiple level sets. Dynamic cases for moving interfaces are presented to demonstrate the method's potential usefulness to arbitrary Lagrangian Eulerian (ALE) methods.

  5. Colovesical fistula secondary to hernia mesh migration: an unusual incident

    OpenAIRE

    Ramanathan, Sabarinathan; Krishnamoorthy, Veeraraghavan; Ratnakar, Kini; Thangavel, Pugazhendhi; Sundarraj, Raju

    2017-01-01

    ABSTRACT We evaluated a 27-year old male with pneumaturia and fecaluria with a past history of right inguinal hernia repair. Though, cystoscopy and contrast enhanced computed tomography did not furnish any evidence to arrive at a diagnosis, interestingly, colonoscopy revealed a mesh in the sigmoid colon making apparent the diagnosis of colovesical fistula secondary to mesh migration. Later, surgical removal of the mesh from the sigmoid colon with rent closure of the fistulous opening was done...

  6. Evaluation of Composite Mesh for Ventral Hernia Repair

    OpenAIRE

    Byrd, Jim F.; Agee, Neal; Nguyen, Phuong H.; Heath, Jessica J.; Lau, Kwan N.; Mckillop, Iain H.; Sindram, David; Martinie, John B.; Iannitti, David A.

    2011-01-01

    Introduction: Composite mesh prostheses incorporate the properties of multiple materials for ventral hernia repair. This study evaluated a polypropylene/ePTFE composite mesh with a novel internal polydioxanone (PDO) absorbable ring. Methods: Composite mesh was placed intraperitoneally in 16 pigs through an open laparotomy and explanted at 2, 4, 8, and 12 weeks. Intraabdominal adhesions were measured laparoscopically. Host tissue in-growth was assessed histologically and tensiometrically. Degr...

  7. THz metal mesh filters on electrically thick fused silica substrates

    OpenAIRE

    Otter, WJ; F. Hu; Hazell, JF; Lucyszyn, S

    2014-01-01

    ? 2014 IEEE.This paper shows simulated and measured results of ultra-low cost metal mesh filters on electrically thick substrates for millimeter-wave and THz bands. It provides a broad overview of metal mesh filters currently available and suggest why it is worth moving to an electrically thick substrate for ultra-low cost applications. We demonstrate scalable traditional metal mesh filters on 525 ?m thick fused silica substrates. In addition, trapped-mode excitation is exploited to improve o...

  8. Hexahedral mesh generation via the dual arrangement of surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, S.A.; Tautges, T.J. [Sandia National Labs., Albuquerque, NM (United States)

    1997-12-31

    Given a general three-dimensional geometry with a prescribed quadrilateral surface mesh, the authors consider the problem of constructing a hexahedral mesh of the geometry whose boundary is exactly the prescribed surface mesh. Due to the specialized topology of hexahedra, this problem is more difficult than the analogous one for tetrahedra. Folklore has maintained that a surface mesh must have a constrained structure in order for there to exist a compatible hexahedral mesh. However, they have proof that a surface mesh need only satisfy mild parity conditions, depending on the topology of the three-dimensional geometry, for there to exist a compatible hexahedral mesh. The proof is based on the realization that a hexahedral mesh is dual to an arrangement of surfaces, and the quadrilateral surface mesh is dual to the arrangement of curves bounding these surfaces. The proof is constructive and they are currently developing an algorithm called Whisker Weaving (WW) that mirrors the proof steps. Given the bounding curves, WW builds the topological structure of an arrangement of surfaces having those curves as its boundary. WW progresses in an advancing front manner. Certain local rules are applied to avoid structures that lead to poor mesh quality. Also, after the arrangement is constructed, additional surfaces are inserted to separate features, so e.g., no two hexahedra share more than one quadrilateral face. The algorithm has generated meshes for certain non-trivial problems, but is currently unreliable. The authors are exploring strategies for consistently selecting which portion of the surface arrangement to advance based on the existence proof. This should lead us to a robust algorithm for arbitrary geometries and surface meshes.

  9. Clinical predictors and risk factors for vaginal mesh extrusion.

    Science.gov (United States)

    Khrucharoen, Usah; Ramart, Patkawat; Choi, Judy; Kang, Diana; Kim, Ja-Hong; Raz, Shlomo

    2017-11-24

    Our study aims to enhance the accuracy of the clinical diagnosis in patients with vaginal mesh extrusion following transvaginal mesh placement for pelvic organ prolapse using significant clinical parameters and risk factors. All patients who underwent vaginal mesh removal were retrospectively reviewed from January 2000 to May 2014. Eligible patients were divided into two groups according to the presence of vaginal mesh extrusion. A total of 862 patients, 798 were included. 357 (44.7%) had evidence of vaginal mesh extrusion, and 441 (55.3%) had no evidence of vaginal mesh extrusion. The mean age of the vaginal mesh extrusion group was slightly higher than in the group without vaginal mesh extrusion (58.7 ± 11.2 vs. 56.4 ± 11.5, respectively; p = 0.002). From multivariate analysis, the significant clinical correlations for vaginal mesh extrusion were vaginal bleeding [60 (16.9) vs. 14 (3.2%), p vaginal discharge [45 (12.6) vs. 18 (4.1%), p = 0.001]. The risk factors were multiple mesh implantations [218 (67.06) vs. 175 (39.68%), p vaginal atrophy, both local and systemic hormonal use, smoking status, and hysterectomy status, were not significantly different, as well as the clinical symptoms including dyspareunia, vaginal infection, and symptomatic vaginal bulge. Vaginal bleeding, hispareunia, and vaginal discharge were the most significant clinical predictors for raising suspicion of vaginal mesh extrusion. Multiple mesh implantations were a significant risk factor for extrusion.

  10. Repair of large frontal temporal parietal skull defect with digitally reconstructed titanium mesh: a report of 20 cases

    Directory of Open Access Journals (Sweden)

    Gang-ge CHENG

    2013-09-01

    Full Text Available Objective To explore the clinical effect and surgical technique of the repair of large defect involving frontal, temporal, and parietal regions using digitally reconstructed titanium mesh. Methods Twenty patients with large frontal, temporal, and parietal skull defect hospitalized in Air Force General Hospital from November 2006 to May 2012 were involved in this study. In these 20 patients, there were 13 males and 7 females, aged 18-58 years (mean 39 years, and the defect size measured from 7.0cm×9.0cm to 11.5cm×14.0cm (mean 8.5cm×12.0cm. Spiral CT head scan and digital three-dimensional reconstruction of skull were performed in all the patients. The shape and geometric size of skull defect was traced based on the symmetry principle, and then the data were transferred into digital precision lathe to reconstruct a titanium mesh slightly larger (1.0-1.5cm than the skull defect, and the finally the prosthesis was perfected after pruning the border. Cranioplasty was performed 6-12 months after craniotomy using the digitally reconstructed titanium mesh. Results The digitally reconstructed titanium mesh was used in 20 patients with large frontal, temporal, parietal skull defect. The surgical technique was relatively simple, and the surgical duration was shorter than before. The titanium mesh fit to the defect of skull accurately with satisfactory molding effect, good appearance and symmetrical in shape. No related complication was found in all the patients. Conclusion Repair of large frontal, temporal, parietal skull defect with digitally reconstructed titanium mesh is more advantageous than traditional manual reconstruction, and it can improve the life quality of patients.

  11. [Prolapse surgery. With abdominal or vaginal meshes?].

    Science.gov (United States)

    Loertzer, H; Schneider, P; Thelen, P; Ringert, R H; Strauß, A

    2012-09-01

    In prolapse surgery several surgical techniques are available. The different open, laparoscopic and vaginal approaches are distinguished by distinct success and relapse rates and operation-specific complications. A safe and optimal therapeutic pelvic floor surgery should be based on the three support levels according to DeLancy and be individually adjusted for every patient. The vaginal approach may be used for all kinds of female genital prolapse and is a comparatively less invasive technique with a short time of convalescence. Apart from stress incontinence there is no need for synthetic meshes in primary approaches and excellent results with low complication and relapse rates can be achieved. An uncritical application of synthetic material is to be avoided in vaginal repair at all times. Abdominal surgical techniques, both open and laparoscopic, present their strengths in the therapeutic approach to level 1 defects or stress incontinence. They provide excellent functional and anatomical corrections and low relapse rates. Abdominally inserted meshes have lower complication rates than vaginal ones.

  12. Nonconforming finite element methods on quadrilateral meshes

    Science.gov (United States)

    Hu, Jun; Zhang, ShangYou

    2013-12-01

    It is well-known that it is comparatively difficult to design nonconforming finite elements on quadrilateral meshes by using Gauss-Legendre points on each edge of triangulations. One reason lies in that these degrees of freedom associated to these Gauss-Legendre points are not all linearly independent for usual expected polynomial spaces, which explains why only several lower order nonconforming quadrilateral finite elements can be found in literature. The present paper proposes two families of nonconforming finite elements of any odd order and one family of nonconforming finite elements of any even order on quadrilateral meshes. Degrees of freedom are given for these elements, which are proved to be well-defined for their corresponding shape function spaces in a unifying way. These elements generalize three lower order nonconforming finite elements on quadrilaterals to any order. In addition, these nonconforming finite element spaces are shown to be full spaces which is somehow not discussed for nonconforming finite elements in literature before.

  13. The Tera Multithreaded Architecture and Unstructured Meshes

    Science.gov (United States)

    Bokhari, Shahid H.; Mavriplis, Dimitri J.

    1998-01-01

    The Tera Multithreaded Architecture (MTA) is a new parallel supercomputer currently being installed at San Diego Supercomputing Center (SDSC). This machine has an architecture quite different from contemporary parallel machines. The computational processor is a custom design and the machine uses hardware to support very fine grained multithreading. The main memory is shared, hardware randomized and flat. These features make the machine highly suited to the execution of unstructured mesh problems, which are difficult to parallelize on other architectures. We report the results of a study carried out during July-August 1998 to evaluate the execution of EUL3D, a code that solves the Euler equations on an unstructured mesh, on the 2 processor Tera MTA at SDSC. Our investigation shows that parallelization of an unstructured code is extremely easy on the Tera. We were able to get an existing parallel code (designed for a shared memory machine), running on the Tera by changing only the compiler directives. Furthermore, a serial version of this code was compiled to run in parallel on the Tera by judicious use of directives to invoke the "full/empty" tag bits of the machine to obtain synchronization. This version achieves 212 and 406 Mflop/s on one and two processors respectively, and requires no attention to partitioning or placement of data issues that would be of paramount importance in other parallel architectures.

  14. Mesh-based parallel code coupling interface

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, K.; Steckel, B. (eds.) [GMD - Forschungszentrum Informationstechnik GmbH, St. Augustin (DE). Inst. fuer Algorithmen und Wissenschaftliches Rechnen (SCAI)

    2001-04-01

    MpCCI (mesh-based parallel code coupling interface) is an interface for multidisciplinary simulations. It provides industrial end-users as well as commercial code-owners with the facility to combine different simulation tools in one environment. Thereby new solutions for multidisciplinary problems will be created. This opens new application dimensions for existent simulation tools. This Book of Abstracts gives a short overview about ongoing activities in industry and research - all presented at the 2{sup nd} MpCCI User Forum in February 2001 at GMD Sankt Augustin. (orig.) [German] MpCCI (mesh-based parallel code coupling interface) definiert eine Schnittstelle fuer multidisziplinaere Simulationsanwendungen. Sowohl industriellen Anwender als auch kommerziellen Softwarehersteller wird mit MpCCI die Moeglichkeit gegeben, Simulationswerkzeuge unterschiedlicher Disziplinen miteinander zu koppeln. Dadurch entstehen neue Loesungen fuer multidisziplinaere Problemstellungen und fuer etablierte Simulationswerkzeuge ergeben sich neue Anwendungsfelder. Dieses Book of Abstracts bietet einen Ueberblick ueber zur Zeit laufende Arbeiten in der Industrie und in der Forschung, praesentiert auf dem 2{sup nd} MpCCI User Forum im Februar 2001 an der GMD Sankt Augustin. (orig.)

  15. Finding Regions of Interest on Toroidal Meshes

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Kesheng; Sinha, Rishi R; Jones, Chad; Ethier, Stephane; Klasky, Scott; Ma, Kwan-Liu; Shoshani, Arie; Winslett, Marianne

    2011-02-09

    Fusion promises to provide clean and safe energy, and a considerable amount of research effort is underway to turn this aspiration intoreality. This work focuses on a building block for analyzing data produced from the simulation of microturbulence in magnetic confinementfusion devices: the task of efficiently extracting regions of interest. Like many other simulations where a large amount of data are produced,the careful study of ``interesting'' parts of the data is critical to gain understanding. In this paper, we present an efficient approach forfinding these regions of interest. Our approach takes full advantage of the underlying mesh structure in magnetic coordinates to produce acompact representation of the mesh points inside the regions and an efficient connected component labeling algorithm for constructingregions from points. This approach scales linearly with the surface area of the regions of interest instead of the volume as shown with bothcomputational complexity analysis and experimental measurements. Furthermore, this new approach is 100s of times faster than a recentlypublished method based on Cartesian coordinates.

  16. Open preperitoneal mesh repair of inguinal hernias using a mesh with nitinol memory frame.

    Science.gov (United States)

    Berrevoet, F; Vanlander, A; Bontinck, J; Troisi, R I

    2013-06-01

    To prospectively evaluate the use of a continuous Nitinol containing memory frame patch during a TIPP-technique in the open repair of inguinal and femoral hernias. Over a 3-year period all consecutive adult patients that needed treatment for an inguinal or femoral hernia were treated by the TIPP repair using the Rebound Shield mesh. Intra-operatively the type and size of the hernia were evaluated according to the EHS classification, as well as the size of the mesh used. Baseline characteristics for all patients were evaluated considering age, gender, BMI and American society of Anesthesiologists score. Standard X-ray was performed to evaluate mesh position. All patients were evaluated for post-operative pain using the visual analogue scale (VAS 0-10 scale). In total 289 groin hernias were operated using a nitinol containing patch in 235 patients. The mean operating time was 38 min for unilateral hernias and 59 min for bilateral hernias. The median follow-up is 21.2 months (14-33 months) during which three patients died, unrelated to the groin hernia repair. At the time of re-evaluation 12 patients (5.0 %) complained of chronic pain, with a VAS score higher than 3 after 3 months (range 3-10). Two of these patients already had severe pain pre-operatively. A total of 3 recurrences (2.9 %) were noted with strong correlation with X-ray findings. A nitinol memory frame containing mesh is a valuable tool to achieve complete deployment of a large pore mesh in a TIPP repair for inguinal hernias with acceptable morbidity and a low recurrence rate.

  17. Intraperitoneal mesh devices for small midline hernias: mesh behavior in a porcine model.

    Science.gov (United States)

    Reynvoet, E; Chiers, K; Van Overbeke, I; Troisi, R; Berrevoet, F

    2015-12-01

    Although clinical data on long-term efficacy are lacking, the use of self-expanding devices for intraperitoneal placement in the management of small midline hernias has been popularized. In the present experimental study, two different devices were investigated regarding tissue ingrowth, adhesion formation and solid mesh placement. Two devices of 4.3 cm diameter, one ePTFE-containing small pore polypropylene mesh (PP/ePTFE) and a multi-layered large-pore polypropylene patch with an oxidized cellulose anti-adhesive barrier (PP/ORC), both containing a self-deployment system, were placed intraperitoneally at the linea alba of 24 female pigs. A first laparoscopy was performed to evaluate mesh positioning against the abdominal wall. 1 (n = 6), 2 (n = 6), 4 (n = 6) and 12 weeks (n = 6) later, mesh appearance was inspected and adhesion formation was assessed. All meshes were excised for histological evaluation. Folding of the patch was more frequently observed at PP/ePTFE, yet no excessive cupping was noticed. Adhesions predominantly presented at short-term evaluation. Overall adhesion formation at all samples was significantly more extensive for PP/ORC (p = 0.048). Massive shrinkage was observed for PP/ORC: after a 12-week period 22% residual surface was preserved, compared to 83% for PP/ePTFE (p < 0.001). While at short-term inflammatory reaction was comparable, at long-term PP/ORC induced a significant more pronounced inflammatory and foreign body reaction. Although a strong deployment system provides adequate initial placement, shrinkage and excessive adhesion formation are much more prominent in the large-pore multi-layered restorbable devices compared to the ePTFE patch. This might influence long-term clinical outcome and caution seems warranted.

  18. Mesh-matrix analysis method for electromagnetic launchers

    Science.gov (United States)

    Elliott, David G.

    1989-01-01

    The mesh-matrix method is a procedure for calculating the current distribution in the conductors of electromagnetic launchers with coil or flat-plate geometry. Once the current distribution is known the launcher performance can be calculated. The method divides the conductors into parallel current paths, or meshes, and finds the current in each mesh by matrix inversion. The author presents procedures for writing equations for the current and voltage relations for a few meshes to serve as a pattern for writing the computer code. An available subroutine package provides routines for field and flux coefficients and equation solution.

  19. Reconfigurable lattice mesh designs for programmable photonic processors.

    Science.gov (United States)

    Pérez, Daniel; Gasulla, Ivana; Capmany, José; Soref, Richard A

    2016-05-30

    We propose and analyse two novel mesh design geometries for the implementation of tunable optical cores in programmable photonic processors. These geometries are the hexagonal and the triangular lattice. They are compared here to a previously proposed square mesh topology in terms of a series of figures of merit that account for metrics that are relevant to on-chip integration of the mesh. We find that that the hexagonal mesh is the most suitable option of the three considered for the implementation of the reconfigurable optical core in the programmable processor.

  20. Hexahedral finite element mesh coarsening using pillowing technique

    Science.gov (United States)

    Staten, Matthew L [Pittsburgh, PA; Woodbury, Adam C [Provo, UT; Benzley, Steven E [Provo, UT; Shepherd, Jason F [Edgewood, NM

    2012-06-05

    A techniques for coarsening a hexahedral mesh is described. The technique includes identifying a coarsening region within a hexahedral mesh to be coarsened. A boundary sheet of hexahedral elements is inserted into the hexahedral mesh around the coarsening region. A column of hexahedral elements is identified within the boundary sheet. The column of hexahedral elements is collapsed to create an extraction sheet of hexahedral elements contained within the coarsening region. Then, the extraction sheet of hexahedral elements is extracted to coarsen the hexahedral mesh.

  1. Randomized trial to compare efficacy of polyester mosquito net mesh with polypropylene mesh in inguinal hernia surgery in northwestern India

    Directory of Open Access Journals (Sweden)

    Sanchit Jain

    2016-12-01

    Conclusions: The results of the short-term follow-up clearly demonstrate that the incidence of postoperative complications from using polyester net mesh is well comparable with that of commercial polypropylene mesh. Using polyester mesh significantly reduces the cost of surgery and therefore it has a role in resource-limited settings. [Arch Clin Exp Surg 2016; 5(4.000: 200-205

  2. MeSH Now: automatic MeSH indexing at PubMed scale via learning to rank

    OpenAIRE

    Mao, Yuqing; Lu, Zhiyong

    2017-01-01

    Background MeSH indexing is the task of assigning relevant MeSH terms based on a manual reading of scholarly publications by human indexers. The task is highly important for improving literature retrieval and many other scientific investigations in biomedical research. Unfortunately, given its manual nature, the process of MeSH indexing is both time-consuming (new articles are not immediately indexed until 2 or 3?months later) and costly (approximately ten dollars per article). In response, a...

  3. Long-term efficacy of the pubovaginal Mersilene mesh sling.

    Science.gov (United States)

    Young, Stephen B; Howard, Allison E; Illanes, Diego S; Weber LeBrun, Emily E; Hardy, Janet R; Kambiss, Scott M; O'Dell, Katharine K; Zhang, Yan

    2009-11-01

    The objective of the study was to determine the efficacy of the pubovaginal Mersilene mesh sling (PVMMS) for complicated urodynamic stress incontinence (USI). Between 1990 and 2008, patients with USI plus an at-risk diagnosis underwent a PVMMS by a single surgeon. They were followed up with urodynamics (UDE) and Pelvic Floor Distress Inventory-short form 20 (PFDI-20). Stratification was in an at-risk hierarchy: intrinsic sphincter deficiency (ISD) greater than recurrent USI (RUSI) greater than USI with chronically increased intraabdominal pressure (CI-IAP). A cough stress test determined objective cure. PFDI question 17 assessed subjective cure. Three hundred six patients with ISD (43.5%), RUSI (26.8%), and CI-IAP (29.7%) had objective cure rates of 89.2% in the short term, 86.7% in the intermediate term, and 91.2% in the long term. A group of 48 patients with both short- and long-term UDEs showed cures of 100% and 91.7%. Long-term objective cure rates were: ISD, 90.5% (n = 21); RUSI, 84.2%, (n = 19); CI-IAP, 100% (n = 17). The mean score of postoperative PFDI question 17 was 0.57 (n = 119). Mean symptom improvement was -2.98 (n = 52; P < .0001). We demonstrated PVMMS to be subjectively and objectively effective in long-term treatment of complicated forms of USI.

  4. Tolerance of the Head and Neck to -Gx Inertial Loading of the Head

    Science.gov (United States)

    1981-03-09

    cervical muscles reduced the inci- dence of "concussion" symptons produced in this animal, Collars on monkeys subjected to flexion producing occipital...muscles reduced the incidence of "concussion" symptoms produced in this animal. Collars on monkeys subjected to flexion producing occipital impacts, were...4 In a repeat run to determine what caused the losA of un- consciousness in Run 133, Stapp, with head held down to aviod amplification of head

  5. MeshVoro: A Three-Dimensional Voronoi Mesh Building Tool for the TOUGH Family of Codes

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, C. M.; Boyle, K. L.; Reagan, M.; Johnson, J.; Rycroft, C.; Moridis, G. J.

    2013-09-30

    Few tools exist for creating and visualizing complex three-dimensional simulation meshes, and these have limitations that restrict their application to particular geometries and circumstances. Mesh generation needs to trend toward ever more general applications. To that end, we have developed MeshVoro, a tool that is based on the Voro (Rycroft 2009) library and is capable of generating complex threedimensional Voronoi tessellation-based (unstructured) meshes for the solution of problems of flow and transport in subsurface geologic media that are addressed by the TOUGH (Pruess et al. 1999) family of codes. MeshVoro, which includes built-in data visualization routines, is a particularly useful tool because it extends the applicability of the TOUGH family of codes by enabling the scientifically robust and relatively easy discretization of systems with challenging 3D geometries. We describe several applications of MeshVoro. We illustrate the ability of the tool to straightforwardly transform a complex geological grid into a simulation mesh that conforms to the specifications of the TOUGH family of codes. We demonstrate how MeshVoro can describe complex system geometries with a relatively small number of grid blocks, and we construct meshes for geometries that would have been practically intractable with a standard Cartesian grid approach. We also discuss the limitations and appropriate applications of this new technology.

  6. [Digital modeling for the individual mandibular 3D mesh scaffold based on 3D printing technology].

    Science.gov (United States)

    Yan, Rongzeng; Luo, Danmei; Qin, Xiaoyu; Li, Runxin; Rong, Qiguo; Hu, Min

    2016-05-01

    To investigate an ideal modeling method of designing 3D mesh scaffold substitutes based on tissue engineering to restore mandibular bone defects. By analyzing the theoretical model from titanium scaffolds fabricated by 3D printing, the feasibility and effectiveness of the proposed methodology were verified. Based on the CT scanned data of a subject, the Mimics 15.0 and Geomagic studio 12.0 reverse engineering software were adopted to generate surface model of mandibular bone and the defect area was separated from the 3D model of bone. Then prosthesis was designed via mirror algorithm, in which outer shape was used as the external shape of scaffold. Unigraphics software NX 8.5 was applied on Boolean calculation of subtraction between prosthesis and regular microstructure structure and ANSYS 14.0 software was used to design the inner construction of 3D mesh scaffolds. The topological structure and the geometrical parameters of 3D mesh titanium scaffolds were adjusted according to the aim of optimized structure and maximal strength with minimal weight. The 3D mesh scaffolds solid model through two kinds of computer-aided methods was input into 3D printing equipment to fabricate titanium scaffolds. Individual scaffolds were designed successfully by two modeling methods. The finite element optimization made 10% decrease of the stress peak and volume decrease of 43%, and the porosity increased to 76.32%. This modeling method was validated by 3D printing titanium scaffold to be feasible and effective. 3D printing technology combined with finite element topology optimization to obtain the ideal mandibular 3D mesh scaffold is feasible and effective.

  7. Head injury - first aid

    Science.gov (United States)

    ... medlineplus.gov/ency/article/000028.htm Head injury - first aid To use the sharing features on this page, ... a concussion can range from mild to severe. First Aid Learning to recognize a serious head injury and ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the head is typically used to detect: bleeding, brain injury and skull fractures in patients with head injuries. ... hard time staying still, are claustrophobic or have chronic pain, you may find a CT exam to ...

  9. Head and face reconstruction

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002980.htm Head and face reconstruction To use the sharing features on this page, please enable JavaScript. Head and face reconstruction is surgery to repair or reshape deformities ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  12. Newborn head molding

    Science.gov (United States)

    Newborn cranial deformation; Molding of the newborn's head; Neonatal care - head molding ... The bones of a newborn baby's skull are soft and flexible, with gaps between the plates of bone. The spaces between the bony plates of ...

  13. Porcine head response to blast

    Directory of Open Access Journals (Sweden)

    Jay eShridharani

    2012-05-01

    Full Text Available Recent studies have shown an increase in the frequency of traumatic brain injuries related to blast exposure. However, the mechanisms that cause blast neurotrauma are unknown. Blast neurotrauma research using computational models has been one method to elucidate that response of the brain in blast, and to identify possible mechanical correlates of injury. However, model validation against experimental data is required to ensure that the model output is representative of in vivo biomechanical response. This study exposed porcine subjects to primary blast overpressures generated using a compressed-gas shock tube. Shock tube blasts were directed to the unprotected head of each animal while the lungs and thorax were protected using ballistic protective vests similar to those employed in theater. The test conditions ranged from 110-740 kPa peak incident overpressure with scaled durations from 1.3-6.9 ms and correspond approximately with a 50% injury risk for brain bleeding and apnea in a ferret model scaled to porcine exposure. The bulk head acceleration and the pressure at the surface of the head and in the cranial cavity were measured. Immediately after the blast, 5 of the 20 animals tested were apneic. Three subjects recovered without intervention within thirty seconds and the remaining two recovered within 8 minutes following bagging and administration of the respiratory stimulant doxapram. Gross examination of the brain revealed no indication of bleeding. Intracranial pressures ranged from 80-685 kPa as a result of the blast and were notably lower than the shock tube reflected pressures of 300-2830 kPa, indicating pressure attenuation by the skull up to a factor of 8.4. Peak head accelerations were measured from 385-3845 G’s and were well correlated with peak incident overpressure (R2=0.90. One standard deviation corridors for the surface pressure, intracranial pressure, and head acceleration are presented to provide experimental data for

  14. Visualization of Scalar Adaptive Mesh Refinement Data

    Energy Technology Data Exchange (ETDEWEB)

    VACET; Weber, Gunther; Weber, Gunther H.; Beckner, Vince E.; Childs, Hank; Ligocki, Terry J.; Miller, Mark C.; Van Straalen, Brian; Bethel, E. Wes

    2007-12-06

    Adaptive Mesh Refinement (AMR) is a highly effective computation method for simulations that span a large range of spatiotemporal scales, such as astrophysical simulations, which must accommodate ranges from interstellar to sub-planetary. Most mainstream visualization tools still lack support for AMR grids as a first class data type and AMR code teams use custom built applications for AMR visualization. The Department of Energy's (DOE's) Science Discovery through Advanced Computing (SciDAC) Visualization and Analytics Center for Enabling Technologies (VACET) is currently working on extending VisIt, which is an open source visualization tool that accommodates AMR as a first-class data type. These efforts will bridge the gap between general-purpose visualization applications and highly specialized AMR visual analysis applications. Here, we give an overview of the state of the art in AMR scalar data visualization research.

  15. Transport Protocols for Wireless Mesh Networks

    Science.gov (United States)

    Eddie Law, K. L.

    Transmission control protocol (TCP) provides reliable connection-oriented services between any two end systems on the Internet. With TCP congestion control algorithm, multiple TCP connections can share network and link resources simultaneously. These TCP congestion control mechanisms have been operating effectively in wired networks. However, performance of TCP connections degrades rapidly in wireless and lossy networks. To sustain the throughput performance of TCP connections in wireless networks, design modifications may be required accordingly in the TCP flow control algorithm, and potentially, in association with other protocols in other layers for proper adaptations. In this chapter, we explain the limitations of the latest TCP congestion control algorithm, and then review some popular designs for TCP connections to operate effectively in wireless mesh network infrastructure.

  16. Adaptive Mesh Refinement for Characteristic Grids

    CERN Document Server

    Thornburg, Jonathan

    2009-01-01

    I consider techniques for Berger-Oliger adaptive mesh refinement (AMR) when numerically solving partial differential equations with wave-like solutions, using characteristic (double-null) grids. Such AMR algorithms are naturally recursive, and the best-known past Berger-Oliger characteristic AMR algorithm, that of Pretorius & Lehner (J. Comp. Phys. 198 (2004), 10), recurses on individual "diamond" characteristic grid cells. This leads to the use of fine-grained memory management, with individual grid cells kept in 2-dimensional linked lists at each refinement level. This complicates the implementation and adds overhead in both space and time. Here I describe a Berger-Oliger characteristic AMR algorithm which instead recurses on null \\emph{slices}. This algorithm is very similar to the usual Cauchy Berger-Oliger algorithm, and uses relatively coarse-grained memory management, allowing entire null slices to be stored stored in contiguous arrays in memory. The algorithm is very efficient in both space and ti...

  17. Parallel-In-Time For Moving Meshes

    Energy Technology Data Exchange (ETDEWEB)

    Falgout, R. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Manteuffel, T. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Southworth, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Schroder, J. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-02-04

    With steadily growing computational resources available, scientists must develop e ective ways to utilize the increased resources. High performance, highly parallel software has be- come a standard. However until recent years parallelism has focused primarily on the spatial domain. When solving a space-time partial di erential equation (PDE), this leads to a sequential bottleneck in the temporal dimension, particularly when taking a large number of time steps. The XBraid parallel-in-time library was developed as a practical way to add temporal parallelism to existing se- quential codes with only minor modi cations. In this work, a rezoning-type moving mesh is applied to a di usion problem and formulated in a parallel-in-time framework. Tests and scaling studies are run using XBraid and demonstrate excellent results for the simple model problem considered herein.

  18. Generating quality tetrahedral meshes from binary volumes

    DEFF Research Database (Denmark)

    Hansen, Mads Fogtmann; Bærentzen, Jakob Andreas; Larsen, Rasmus

    2010-01-01

    generation algorithm on four examples (torus, Stanford dragon, brain mask, and pig back) and report the dihedral angle, aspect ratio and radius-edge ratio. Even though, the algorithm incorporates none of the mentioned quality measures in the compression stage it receives a good score for all these measures......This paper presents two new quality measures for tetrahedra which are smooth and well-suited for gradient based optimization. Both measures are formulated as a distance from the regular tetrahedron and utilize the fact that the covariance of the vertices of a regular tetrahedron is isotropic. We...... use these measures to generate high quality meshes from signed distance maps. This paper also describes an approach for computing (smooth) signed distance maps from binary volumes as volumetric data in many cases originate from segmentation of objects from imaging techniques such as CT, MRI, etc...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... top of page What are some common uses of the procedure? CT scanning of the head is ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, dizziness, and other symptoms of ... content. Related Articles and Media Radiation Dose in X-Ray and CT ... Perfusion of the Head CT Angiography (CTA) Stroke Brain Tumors Computer Tomography ( ...

  1. Treatment of anterior vaginal wall prolapse with and without polypropylene mesh: a prospective, randomized and controlled trial - Part I

    Directory of Open Access Journals (Sweden)

    Jose Tadeu Nunes Tamanini

    2013-07-01

    Full Text Available Objective To compare the use of polypropylene mesh (PM and the traditional anterior vaginal wall colporraphy in women with anterior vaginal wall prolapse (AVWP using objective and subjective tests and evaluation of quality of life (QoL. Materials and Methods One hundred women were randomly distributed in two preoperatory groups. The first group (mesh (n = 45 received a PM implant and the control group (n = 55 was submitted to traditional colporraphy. Postoperatory follow-up was done after 12 months. The primary objective was the correction of the Ba point ≤ -2 POP-Q (Pelvic Organ Prolapse Quantification System and the secondary objective was the improvement of vaginal symptoms and QoL through ICIQ-VS (International Consultation on Incontinence Questionnaire - Vaginal Symptoms. Complications related to the use of PM or not were also described. Results There was a significant difference between all POP-Q measures of pre- and postoperatory periods of each group in particular. There was a significant difference of the Ba point of the postoperatory period between the Mesh and Control group. The mean of Ba point in the Mesh group was statistically lower than of the Control group, depicting the better anatomical result of the first group. Both techniques improved vaginal symptoms and QoL. The most frequent complication of the Mesh group was prepubic hematoma in the perioperative period. In 9.3% of the cases treated with mesh it was observed PM exposition at the anterior vaginal wall after 12 months, being most of them treated clinically. Conclusion The treatment of AVWP significantly improved the Ba point in the Mesh group in comparison to the Control group. There were no differences of the vaginal symptoms and QoL between the two groups after 12 months. There were few and low grade complications on both groups.

  2. Recurrence and Pain after Mesh Repair of Inguinal Hernias

    African Journals Online (AJOL)

    Hernia System and Lichtenstein Method for Open. Inguinal Hernia Repair. J Clin Diagn Res. 2015;. 9(6): PC04-PC07. 3. Grant AM. Open Mesh Versus Non-Mesh Repair of Groin Hernia: Meta-Analysis of Randomised. Trials Based on Individual Patient Data. EU Hernia. Trialists Collaboration. Hernia. 2002; 6(3):130-6. 4.

  3. Sen migration af mesh til colon efter laparoskopisk hernieoperation

    DEFF Research Database (Denmark)

    Rasmussen, Martin; Bisgaard, Thue

    2014-01-01

    Long-term complications after laparoscopic ventral hernia repair with mesh reinforcement are not well documented in the literature. We describe a case of a 63-year-old woman with repeated hernia operations due to a ventral hernia, which ultimately was complicated with mesh migration into the tran...... into the transverse colon....

  4. Late mesh migration into the colon after laparoscopic herniotomy

    DEFF Research Database (Denmark)

    Rasmussen, Martin; Bisgaard, Thue

    2014-01-01

    Long-term complications after laparoscopic ventral hernia repair with mesh reinforcement are not well documented in the literature. We describe a case of a 63-year-old woman with repeated hernia operations due to a ventral hernia, which ultimately was complicated with mesh migration into the tran...... into the transverse colon....

  5. Mesh may fit in as a termite barrier

    Science.gov (United States)

    Bradford M. Kard

    1999-01-01

    Stainless steel mesh tests are currently being conducted in an effort to investigate alternatives or supplements to termiticides for control of subterranean termites. Some people are extra sensitive to insecticides or would prefer to use non-insecticidal means to control termites, and stainless steel mesh may provide one such alternative.

  6. The use of mesh implants in vaginal prolapse surgery: Position ...

    African Journals Online (AJOL)

    , or the use of full-length mid-urethral mesh for the treatment of stress urinary incontinence (e.g. tension-free vaginal tape/transobturator sling tape). In January 2012, the FDA introduced mandatory postmarket surveillance of all mesh implanted ...

  7. Tangle-Free Finite Element Mesh Motion for Ablation Problems

    Science.gov (United States)

    Droba, Justin

    2016-01-01

    In numerical simulations involving boundaries that evolve in time, the primary challenge is updating the computational mesh to reflect the physical changes in the domain. In particular, the fundamental objective for any such \\mesh motion" scheme is to maintain mesh quality and suppress unphysical geometric anamolies and artifacts. External to a physical process of interest, mesh motion is an added component that determines the specifics of how to move the mesh given certain limited information from the main system. This paper develops a set of boundary conditions designed to eliminate tangling and internal collision within the context of PDE-based mesh motion (linear elasticity). These boundary conditions are developed for two- and three-dimensional meshes. The paper presents detailed algorithms for commonly occuring topological scenarios and explains how to apply them appropriately. Notably, the techniques discussed herein make use of none of the specifics of any particular formulation of mesh motion and thus are more broadly applicable. The two-dimensional algorithms are validated by an extensive verification procedure. Finally, many examples of diverse geometries in both two- and three-dimensions are shown to showcase the capabilities of the tangle-free boundary conditions.

  8. VARIABLE MESH STIFFNESS OF SPUR GEAR TEETH USING ...

    African Journals Online (AJOL)

    primary source of parametric vibration excitation in geared systems, by virtue of large magnitude change in stiffness that occurs during gear engagement. A gear mesh kinematic simulation. WIll be developeJ 1(1 simulate the meshing actIOn 01 two spur gears,. Recently, greatcr elliphasis has been played on the creation of ...

  9. Macrophage polarization in response to ECM coated polypropylene mesh.

    Science.gov (United States)

    Wolf, Matthew T; Dearth, Christopher L; Ranallo, Christian A; LoPresti, Samuel T; Carey, Lisa E; Daly, Kerry A; Brown, Bryan N; Badylak, Stephen F

    2014-08-01

    The host response to implanted biomaterials is a highly regulated process that influences device functionality and clinical outcome. Non-degradable biomaterials, such as knitted polypropylene mesh, frequently elicit a chronic foreign body reaction with resultant fibrosis. Previous studies have shown that an extracellular matrix (ECM) hydrogel coating of polypropylene mesh reduces the intensity of the foreign body reaction, though the mode of action is unknown. Macrophage participation plays a key role in the development of the foreign body reaction to biomaterials, and therefore the present study investigated macrophage polarization following mesh implantation. Spatiotemporal analysis of macrophage polarization was conducted in response to uncoated polypropylene mesh and mesh coated with hydrated and dry forms of ECM hydrogels derived from either dermis or urinary bladder. Pro-inflammatory M1 macrophages (CD86+/CD68+), alternatively activated M2 macrophages (CD206+/CD68+), and foreign body giant cells were quantified between 3 and 35 days. Uncoated polypropylene mesh elicited a dominant M1 response at the mesh fiber surface, which was decreased by each ECM coating type beginning at 7 days. The diminished M1 response was accompanied by a reduction in the number of foreign body giant cells at 14 and 35 days, though there was a minimal effect upon the number of M2 macrophages at any time. These results show that ECM coatings attenuate the M1 macrophage response and increase the M2/M1 ratio to polypropylene mesh in vivo. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Large-Scale CFD Parallel Computing Dealing with Massive Mesh

    Directory of Open Access Journals (Sweden)

    Zhi Shang

    2013-01-01

    Full Text Available In order to run CFD codes more efficiently on large scales, the parallel computing has to be employed. For example, in industrial scales, it usually uses tens of thousands of mesh cells to capture the details of complex geometries. How to distribute these mesh cells among the multiprocessors for obtaining a good parallel computing performance (HPC is really a challenge. Due to dealing with the massive mesh cells, it is difficult for the CFD codes without parallel optimizations to handle this kind of large-scale computing. Some of the open source mesh partitioning software packages, such as Metis, ParMetis, Scotch, PT-Scotch, and Zoltan, are able to deal with the distribution of large number of mesh cells. Therefore they were employed as the parallel optimization tools ported into Code_Saturne, an open source CFD code, for testing if they can solve the issue of dealing with massive mesh cells for CFD codes. Through the studies, it was found that the mesh partitioning optimization software packages can help CFD codes not only deal with massive mesh cells but also have a good HPC.

  11. Scalable Video Streaming in Wireless Mesh Networks for Education

    Science.gov (United States)

    Liu, Yan; Wang, Xinheng; Zhao, Liqiang

    2011-01-01

    In this paper, a video streaming system for education based on a wireless mesh network is proposed. A wireless mesh network is a self-organizing, self-managing and reliable intelligent network, which allows educators to deploy a network quickly. Video streaming plays an important role in this system for multimedia data transmission. This new…

  12. Surgical management of pelvic floor prolapse in women using mesh ...

    African Journals Online (AJOL)

    Objective: To evaluate surgical handling, prolapse correction and complication rate of polypropylene mesh. Methods: A retrospective review of patients who had pelvic floor repair using polypropylene mesh(PPM) and intra-vaginal sling(IVS), between January 2003 and July 2005. All patients were followed-up for a period of ...

  13. Mesh Processing in Medical-Image Analysis-a Tutorial

    DEFF Research Database (Denmark)

    Levine, Joshua A.; Paulsen, Rasmus Reinhold; Zhang, Yongjie

    2012-01-01

    Medical-image analysis requires an understanding of sophisticated scanning modalities, constructing geometric models, building meshes to represent domains, and downstream biological applications. These four steps form an image-to-mesh pipeline. For research in this field to progress, the imaging...

  14. Volume Decomposition and Feature Recognition for Hexahedral Mesh Generation

    Energy Technology Data Exchange (ETDEWEB)

    GADH,RAJIT; LU,YONG; TAUTGES,TIMOTHY J.

    1999-09-27

    Considerable progress has been made on automatic hexahedral mesh generation in recent years. Several automatic meshing algorithms have proven to be very reliable on certain classes of geometry. While it is always worth pursuing general algorithms viable on more general geometry, a combination of the well-established algorithms is ready to take on classes of complicated geometry. By partitioning the entire geometry into meshable pieces matched with appropriate meshing algorithm the original geometry becomes meshable and may achieve better mesh quality. Each meshable portion is recognized as a meshing feature. This paper, which is a part of the feature based meshing methodology, presents the work on shape recognition and volume decomposition to automatically decompose a CAD model into meshable volumes. There are four phases in this approach: (1) Feature Determination to extinct decomposition features, (2) Cutting Surfaces Generation to form the ''tailored'' cutting surfaces, (3) Body Decomposition to get the imprinted volumes; and (4) Meshing Algorithm Assignment to match volumes decomposed with appropriate meshing algorithms. The feature determination procedure is based on the CLoop feature recognition algorithm that is extended to be more general. Results are demonstrated over several parts with complicated topology and geometry.

  15. Vaginal Approaches Using Synthetic Mesh to Treat Pelvic Organ Prolapse.

    Science.gov (United States)

    Moon, Jei Won; Chae, Hee Dong

    2016-02-01

    Pelvic organ prolapse (POP) is a very common condition in elderly women. In women with POP, a sacrocolpopexy or a vaginal hysterectomy with anterior and posterior colporrhaphy has long been considered as the gold standard of treatment. However, in recent decades, the tendency to use a vaginal approach with mesh for POP surgery has been increasing. A vaginal approach using mesh has many advantages, such as its being less invasive than an abdominal approach and easier to do than a laparoscopic approach and its having a lower recurrence rate than a traditional approach. However, the advantages of a vaginal approach with mesh for POP surgery must be weighed against the disadvantages. Specific complications that have been reported when using mesh in POP procedures are mesh erosion, dyspareunia, hematomas, urinary incontinence and so on, and evidence supporting the use of transvaginal surgery with mesh is still lacking. Hence, surgeons should understand the details of the surgical pelvic anatomy, the various surgical techniques for POP surgery, including using mesh, and the possible side effects of using mesh.

  16. The application of TINA in the MESH project

    NARCIS (Netherlands)

    van Sinderen, Marten J.; Ferreira Pires, Luis; Pires, L.F.; Plagemann, Thomas; Goebel, Vera

    1998-01-01

    This paper discusses the application of TINA concepts, architectures and related design paradigms in the MESH project. MESH adopted TINA as a means to facilitate the design and implementation of a flexible platform for developing and providing interactive multimedia services. This paper reports on

  17. Moving Mesh for the Numerical Solution of Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    OLIVEIRA, F. S.

    2013-06-01

    Full Text Available In this paper we present moving meshes for the numeric resolution of partial differential equations. We describe some important concepts on this topic and point to existing body of work for the solution of partial differential equations using the methods of finite volumes and finite elements, both with moving meshes.

  18. Staged Closure of Giant Omphalocele using Synthetic Mesh

    OpenAIRE

    Lalit Parida; Kamalesh Pal; Hussah Al Buainain; Hossam Elshafei

    2014-01-01

    Giant omphalocele is difficult to manage and is associated with a poor outcome. A male newborn presented to our hospital with a giant omphalocele. We performed a staged closure of giant omphalocele using synthetic mesh to construct a silo and then mesh abdominoplasty in the neonatal period that led to a successful outcome within a reasonable period of hospital stay.

  19. Surface mesh to voxel data registration for patient-specific anatomical modeling

    Science.gov (United States)

    de Oliveira, Júlia E. E.; Giessler, Paul; Keszei, András.; Herrler, Andreas; Deserno, Thomas M.

    2016-03-01

    Virtual Physiological Human (VPH) models are frequently used for training, planning, and performing medical procedures. The Regional Anaesthesia Simulator and Assistant (RASimAs) project has the goal of increasing the application and effectiveness of regional anesthesia (RA) by combining a simulator of ultrasound-guided and electrical nerve-stimulated RA procedures and a subject-specific assistance system through an integration of image processing, physiological models, subject-specific data, and virtual reality. Individualized models enrich the virtual training tools for learning and improving regional anaesthesia (RA) skills. Therefore, we suggest patient-specific VPH models that are composed by registering the general mesh-based models with patient voxel data-based recordings. Specifically, the pelvis region has been focused for the support of the femoral nerve block. The processing pipeline is composed of different freely available toolboxes such as MatLab, the open Simulation framework (SOFA), and MeshLab. The approach of Gilles is applied for mesh-to-voxel registration. Personalized VPH models include anatomical as well as mechanical properties of the tissues. Two commercial VPH models (Zygote and Anatomium) were used together with 34 MRI data sets. Results are presented for the skin surface and pelvic bones. Future work will extend the registration procedure to cope with all model tissue (i.e., skin, muscle, bone, vessel, nerve, fascia) in a one-step procedure and extrapolating the personalized models to body regions actually being out of the captured field of view.

  20. A Density Control Based Adaptive Hexahedral Mesh Generation Algorithm

    Directory of Open Access Journals (Sweden)

    Xiangwei Zhang

    2016-12-01

    Full Text Available A density control based adaptive hexahedral mesh generation algorithm for three dimensional models is presented in this paper. The first step of this algorithm is to identify the characteristic boundary of the solid model which needs to be meshed. Secondly, the refinement fields are constructed and modified according to the conformal refinement templates, and used as a metric to generate an initial grid structure. Thirdly, a jagged core mesh is generated by removing all the elements in the exterior of the solid model. Fourthly, all of the surface nodes of the jagged core mesh are matching to the surfaces of the model through a node projection process. Finally, the mesh quality such as topology and shape is improved by using corresponding optimization techniques.

  1. Feature-preserving surface mesh smoothing via suboptimal Delaunay triangulation.

    Science.gov (United States)

    Gao, Zhanheng; Yu, Zeyun; Holst, Michael

    2013-01-01

    A method of triangular surface mesh smoothing is presented to improve angle quality by extending the original optimal Delaunay triangulation (ODT) to surface meshes. The mesh quality is improved by solving a quadratic optimization problem that minimizes the approximated interpolation error between a parabolic function and its piecewise linear interpolation defined on the mesh. A suboptimal problem is derived to guarantee a unique, analytic solution that is significantly faster with little loss in accuracy as compared to the optimal one. In addition to the quality-improving capability, the proposed method has been adapted to remove noise while faithfully preserving sharp features such as edges and corners of a mesh. Numerous experiments are included to demonstrate the performance of the method.

  2. Use of mesh in laparoscopic paraesophageal hernia repair

    DEFF Research Database (Denmark)

    Müller-Stich, Beat P.; Kenngott, Hannes G.; Gondan, Matthias

    2015-01-01

    potential benefits of LMAH. All data regarding LMAH were used to estimate risk of mesh-associated complications. Risk-benefit analysis was performed using a Markov Monte Carlo decision-analytic model. Results. Meta-analysis of 3 RCTs and 9 OCSs including 915 patients revealed a significantly lower......Introduction. Mesh augmentation seems to reduce recurrences following laparoscopic paraesophageal hernia repair (LPHR). However, there is an uncertain risk of mesh-associated complications. Risk-benefit analysis might solve the dilemma. Materials and Methods. A systematic literature search...... of LMAH data yielded a mesh-associated complication rate of 1.9% (41/2121; 95% CI, 1.3% to 2.5%) for those series reporting at least one mesh-associated complication. The Markov Monte Carlo decision-analytic model revealed a procedure-related mortality rate of 1.6% for LMAH and 1.8% for LH. Conclusions...

  3. Challenges in Second-Generation Wireless Mesh Networks

    Directory of Open Access Journals (Sweden)

    Pescapé Antonio

    2008-01-01

    Full Text Available Wireless mesh networks have the potential to provide ubiquitous high-speed Internet access at low costs. The good news is that initial deployments of WiFi meshes show the feasibility of providing ubiquitous Internet connectivity. However, their performance is far below the necessary and achievable limit. Moreover, users' subscription in the existing meshes is dismal even though the technical challenges to get connectivity are low. This paper provides an overview of the current status of mesh networks' deployment, and highlights the technical, economical, and social challenges that need to be addressed in the next years. As a proof-of-principle study, we discuss the above-mentioned challenges with reference to three real networks: (i MagNets, an operator-driven planned two-tier mesh network; (ii Berlin Freifunk network as a pure community-driven single-tier network; (iii Weimar Freifunk network, also a community-driven but two-tier network.

  4. Tangle-Free Finite Element Mesh Motion for Ablation Problems

    Science.gov (United States)

    Droba, Justin

    2016-01-01

    Mesh motion is the process by which a computational domain is updated in time to reflect physical changes in the material the domain represents. Such a technique is needed in the study of the thermal response of ablative materials, which erode when strong heating is applied to the boundary. Traditionally, the thermal solver is coupled with a linear elastic or biharmonic system whose sole purpose is to update mesh node locations in response to altering boundary heating. Simple mesh motion algorithms rely on boundary surface normals. In such schemes, evolution in time will eventually cause the mesh to intersect and "tangle" with itself, causing failure. Furthermore, such schemes are greatly limited in the problems geometries on which they will be successful. This paper presents a comprehensive and sophisticated scheme that tailors the directions of motion based on context. By choosing directions for each node smartly, the inevitable tangle can be completely avoided and mesh motion on complex geometries can be modeled accurately.

  5. Study of open inguinal hernia repair by mosquito net mesh versus polypropylene mesh

    OpenAIRE

    Anil Darokar; Kishor Bele; Rajiv Mulmule; Rizwanuddin Qazi

    2016-01-01

    Background: Inguinal hernia is one of the commonest medical problems and treatment with Lichtenstein repair using polypropylene mesh is considered as gold standard. In developing countries, cost of the prosthesis is a significant factor in health care delivery. Methods: A clinical trial of 73 patients of inguinal hernia operated by Lichtenstein tension free technique from 1st January 2013 to 31st December 2014 was undertaken to evaluate the safety, complications and recurrence rate using ...

  6. Novel Application of Cultured Epithelial Autografts (CEA with Expanded Mesh Skin Grafting Over an Artificial Dermis or Dermal Wound Bed Preparation

    Directory of Open Access Journals (Sweden)

    Sadanori Akita

    2017-12-01

    Full Text Available Cultured epithelial autografts (CEA with highly expanded mesh skin grafts were used for extensive adult burns covering more than 30% of the total body surface area. A prospective study on eight patients assessed subjective and objective findings up to a 12-month follow-up. The results of wound healing for over 1:6 mesh plus CEA, gap 1:6 mesh plus CEA, and 1:3 mesh were compared at 3, 6, and 12 months using extensibility, viscoelasticity, color, and transepidermal water loss by a generalized estimating equation (GEE or generalized linear mixed model (GLMM. No significant differences were observed among the paired treatments at any time point. At 6 and 12 months, over 1:6 mesh plus CEA achieved significantly better expert evaluation scores by the Vancouver and Manchester Scar Scales (p < 0.01. Extended skin grafting plus CEA minimizes donor resources and the quality of scars is equal or similar to that with conventional low extended mesh slit-thickness skin grafting such as 1:3 mesh. A longitudinal analysis of scars may further clarify the molecular changes of scar formation and pathogenesis.

  7. Vestibulopathy and age effects on head stability during chair rise.

    Science.gov (United States)

    McGibbon, C A; Krebs, D E; Scarborough, D M

    2001-01-01

    It is unknown how vestibular dysfunction and age differentially affect balance control during functional activities. The objective of this study was to gain insight into the effects of age and vestibulopathy on head control when rising from a chair. Head relative to trunk (head-on-trunk) sagittal plane angular and linear control strategies were studied in patients with bilateral vestibular hypofunction (BVH) and in healthy subjects aged 30-80 years. A two-way analysis of variance was used to compare head-on-trunk kinematics by age (young vs elderly) and diagnosis (healthy vs BVH) at the time of liftoff from the seat. Angular control strategies differed with age but not diagnosis: young (healthy and BVH) subjects stabilized head rotations in space while elderly (healthy and BVH) subjects stabilized head rotations on the trunk. In contrast, linear control strategies differed by diagnosis but not age: BVH subjects (young and old) allowed a greater rate of head-on-trunk translation while healthy subjects (young and old) inhibited such translations. Young BVH subjects stabilized head-in-space rotations (as did young healthy subjects) without a functioning vestibular system, suggesting cervicocollic reflex and/or other sensory compensation for vestibular loss. Elderly BVH subjects stabilized head rotation with respect to the trunk, as did healthy elders, but did not stabilize head-on-trunk translations, suggesting a reliance on passive mechanical responses of the neck to sense head movements. We conclude that compensation strategies used by patients with vestibulopathy are age-dependent and appear to be more tractable in the younger BVH patient.

  8. Developing metal coated mesh filters for mid-infrared astronomy

    Science.gov (United States)

    Sako, Shigeyuki; Miyata, Takashi; Kamizuka, Takafumi; Nakamura, Tomohiko; Asano, Kentaro; Uchiyama, Mizuho; Onaka, Takashi; Sakon, Itsuki; Wada, Takehiko

    2012-09-01

    A metal mesh filter is appropriate to a band-pass filter for astronomy in the long mid-infrared between 25 and 40 μm, where most of optical materials are opaque. The mesh filter does not require transparent dielectric materials unlike interference filters because the transmission characteristics bare determined by surface plasmon-polariton (SPP) resonances excited on a metal surface with a periodic structure. In this study, we have developed the mesh filters optimized to atmospheric windows at 31.8 and 37.5 μm accessible from the Chajnantor site of 5,640 m altitude. First, mesh filters made of a gold film of 2 μm thickness have been fabricated. Four identical film-type filters are stacked incoherently to suppress leakages at stop-bands. The transmissions of the stacked filters have been measured to be 0.8 at the peaks and below 1 x 10-3 at the stop-bands at 4 K. The ground-based mid-infrared camera MAX38 has been equipped with the stacked filters and successfully obtained diffraction-limited stellar images at the Chajnantor site. The film-type mesh filter does not have sufficient mechanical strength for a larger aperture and for use in space. We have developed mesh filters with higher strength by applying the membrane technology for x-ray optics. The membrane-type mesh filter is made of SiC and coated with a thin gold layer. The optical performance of the mesh filter is independent of internal materials in principle because the SPP resonances are excited only on the metal surface. The fabricated membrane-type mesh filter has been confirmed to provide comparable optical performance to the film-type mesh filter.

  9. Robust, multidimensional mesh motion based on Monge-Kantorovich equidistribution

    Energy Technology Data Exchange (ETDEWEB)

    Delzanno, G L [Los Alamos National Laboratory; Finn, J M [Los Alamos National Laboratory

    2009-01-01

    Mesh-motion (r-refinement) grid adaptivity schemes are attractive due to their potential to minimize the numerical error for a prescribed number of degrees of freedom. However, a key roadblock to a widespread deployment of the technique has been the formulation of robust, reliable mesh motion governing principles, which (1) guarantee a solution in multiple dimensions (2D and 3D), (2) avoid grid tangling (or folding of the mesh, whereby edges of a grid cell cross somewhere in the domain), and (3) can be solved effectively and efficiently. In this study, we formulate such a mesh-motion governing principle, based on volume equidistribution via Monge-Kantorovich optimization (MK). In earlier publications [1, 2], the advantages of this approach in regards to these points have been demonstrated for the time-independent case. In this study, demonstrate that Monge-Kantorovich equidistribution can in fact be used effectively in a time stepping context, and delivers an elegant solution to the otherwise pervasive problem of grid tangling in mesh motion approaches, without resorting to ad-hoc time-dependent terms (as in moving-mesh PDEs, or MMPDEs [3, 4]). We explore two distinct r-refinement implementations of MK: direct, where the current mesh relates to an initial, unchanging mesh, and sequential, where the current mesh is related to the previous one in time. We demonstrate that the direct approach is superior in regards to mesh distortion and robustness. The properties of the approach are illustrated with a paradigmatic hyperbolic PDE, the advection of a passive scalar. Imposed velocity flow fields or varying vorticity levels and flow shears are considered.

  10. Resorbable biosynthetic mesh for crural reinforcement during hiatal hernia repair.

    Science.gov (United States)

    Alicuben, Evan T; Worrell, Stephanie G; DeMeester, Steven R

    2014-10-01

    The use of mesh to reinforce crural closure during hiatal hernia repair is controversial. Although some studies suggest that using synthetic mesh can reduce recurrence, synthetic mesh can erode into the esophagus and in our opinion should be avoided. Studies with absorbable or biologic mesh have not proven to be of benefit for recurrence. The aim of this study was to evaluate the outcome of hiatal hernia repair with modern resorbable biosynthetic mesh in combination with adjunct tension reduction techniques. We retrospectively analyzed all patients who had crural reinforcement during repair of a sliding or paraesophageal hiatal hernia with Gore BioA resorbable mesh. Objective follow-up was by videoesophagram and/or esophagogastroduodenoscopy. There were 114 patients. The majority of operations (72%) were laparoscopic primary repairs with all patients receiving a fundoplication. The crura were closed primarily in all patients and reinforced with a BioA mesh patch. Excessive tension prompted a crural relaxing incision in four per cent and a Collis gastroplasty in 39 per cent of patients. Perioperative morbidity was minor and unrelated to the mesh. Median objective follow-up was one year, but 18 patients have objective follow-up at two or more years. A recurrent hernia was found in one patient (0.9%) three years after repair. The use of crural relaxing incisions and Collis gastroplasty in combination with crural reinforcement with resorbable biosynthetic mesh is associated with a low early hernia recurrence rate and no mesh-related complications. Long-term follow-up will define the role of these techniques for hiatal hernia repair.

  11. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head ... limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is ...

  12. Eye-Head Coordination for Visual Cognitive Processing

    Science.gov (United States)

    Fang, Yu; Nakashima, Ryoichi; Matsumiya, Kazumichi; Kuriki, Ichiro; Shioiri, Satoshi

    2015-01-01

    We investigated coordinated movements between the eyes and head (“eye-head coordination”) in relation to vision for action. Several studies have measured eye and head movements during a single gaze shift, focusing on the mechanisms of motor control during eye-head coordination. However, in everyday life, gaze shifts occur sequentially and are accompanied by movements of the head and body. Under such conditions, visual cognitive processing influences eye movements and might also influence eye-head coordination because sequential gaze shifts include cycles of visual processing (fixation) and data acquisition (gaze shifts). In the present study, we examined how the eyes and head move in coordination during visual search in a large visual field. Subjects moved their eyes, head, and body without restriction inside a 360° visual display system. We found patterns of eye-head coordination that differed those observed in single gaze-shift studies. First, we frequently observed multiple saccades during one continuous head movement, and the contribution of head movement to gaze shifts increased as the number of saccades increased. This relationship between head movements and sequential gaze shifts suggests eye-head coordination over several saccade-fixation sequences; this could be related to cognitive processing because saccade-fixation cycles are the result of visual cognitive processing. Second, distribution bias of eye position during gaze fixation was highly correlated with head orientation. The distribution peak of eye position was biased in the same direction as head orientation. This influence of head orientation suggests that eye-head coordination is involved in gaze fixation, when the visual system processes retinal information. This further supports the role of eye-head coordination in visual cognitive processing. PMID:25799510

  13. [Use of adhesive mesh in hernioplasty compared to the conventional technique. Results of a randomised prospective study].

    Science.gov (United States)

    Bruna Esteban, Marcos; Cantos Pallarés, Miriam; Artigues Sánchez De Rojas, Enrique

    2010-10-01

    The use of meshes made with reabsorbable materials and structures that allow them to be fixed to the tissue without sutures, is considered as a therapeutic possibility in inguinal hernioplasty, reducing surgical times and supposedly improving pain and post-operative recovery. A prospective randomised study of patients intervened for inguinal hernia between March 2009 and March 2010. Those patients subjected to hernia repair with a self-adhesive mesh (Parietene Progrip(®)) were placed in the in the SA (self-adhesive) group, and those subjected to hernia repair with a polypropylene mesh fixed with a monofilament suture in the CL (Classic Lichenstein) group. Complications and pain, using the visual analogue scale, were evaluated over 7 days. A total of 90 patients were divided into 2 groups of 45. The mean age was 60 y and 49 years, respectively, with the mean size of the hernia defect being 3cm, and approximately 60% were indirect hernias. The time of fixing the mesh and the overall surgery time was lower in the SA group than in the LC group: 56s versus 3min and 52s, and 17min and 45s versus 20min and 10s, respectively. There were no differences in hospital stay, complications or post-operative pain. The use of this type of mesh reduces the time of fixing the prosthesis and the total surgical time, with no effect on early post-operative pain or surgical complications compared to hernioplasty with a polypropylene mesh fixed with a monofilament suture. Copyright © 2010 AEC. Published by Elsevier Espana. All rights reserved.

  14. Expanding subjectivities

    DEFF Research Database (Denmark)

    Lundgaard Andersen, Linda; Soldz, Stephen

    2012-01-01

    A major theme in recent psychoanalytic thinking concerns the use of therapist subjectivity, especially “countertransference,” in understanding patients. This thinking converges with and expands developments in qualitative research regarding the use of researcher subjectivity as a tool to understa...

  15. Bilateral Morgagni Hernia: Primary Repair without a Mesh

    Directory of Open Access Journals (Sweden)

    Vassilios Papanikolaou

    2008-07-01

    Full Text Available We present a case of bilateral Morgagni hernia in a 68-year-old male with an intermittent history of progressive onset of breath shortness and occasional cardiac arrhythmias. Diagnosis was made by clinical examination and the findings in a plain chest radiograph and was confirmed by computed tomography scan. The patient was operated electively and subjected to a transabdominal approach. A bilateral subcostal incision revealed a large right side anterior diaphragmatic defect with a hernia containing the ascending colon, the majority of the transverse colon and a huge amount of omentum. Also a second smaller defect was found on the left side with no hernia inside. After large bowel and omentum had been taken down to the peritoneal cavity, both defects were primarily closed using interrupted nylon sutures without the use of a mesh. The patient recovered very well, had an uneventful postoperative course and was released on the 5th postoperative day. 15-month follow-up failed to reveal any signs of recurrence.

  16. Evaluation of composite mesh for ventral hernia repair.

    Science.gov (United States)

    Byrd, Jim F; Agee, Neal; Nguyen, Phuong H; Heath, Jessica J; Lau, Kwan N; McKillop, Iain H; Sindram, David; Martinie, John B; Iannitti, David A

    2011-01-01

    Composite mesh prostheses incorporate the properties of multiple materials for ventral hernia repair. This study evaluated a polypropylene/ePTFE composite mesh with a novel internal polydioxanone (PDO) absorbable ring. Composite mesh was placed intraperitoneally in 16 pigs through an open laparotomy and explanted at 2, 4, 8, and 12 weeks. Intraabdominal adhesions were measured laparoscopically. Host tissue in-growth was assessed histologically and tensiometrically. Degradation of the internal PDO ring component was also measured tensiometrically. Appropriate statistical tests were used, and P ≤.05 indicated significance. No adhesions were formed in 50% of the grafts explanted at 8 weeks and 25% of grafts explanted at 12 weeks. There were significantly more vascular structures at 8 weeks, 73.5 ± 28, compared with 2 weeks, 6.75 ± 2 (P ≤.01). The T-peel force at the mesh-host tissue interface was not significantly different among time points. The absorbable PDO ring underwent complete degradation by 12 weeks. This composite mesh was associated with minimal intraabdominal adhesions, progressive in-growth of host tissues, and complete degradation of a novel internal PDO ring that aided mesh positioning. This composite hernia mesh showed a favorable performance in a porcine model of open ventral hernia repair.

  17. Design Investigation on Applicable Mesh Structures for Medical Stent Applications

    Science.gov (United States)

    Asano, Shoji; He, Jianmei

    2017-11-01

    In recent years, utilization of medical stents is one of effective treatments for stenosis and occlusion occurring in a living body’s lumen indispensable for maintenance of human life such as superficial femoral artery (SFA) occlusion. However, there are concerns about the occurrence of fatigue fractures caused by stress concentrations, neointimal hyperplasia and the like due to the shape structure and the manufacturing method in the conventional stents, and a stent having high strength and high flexibility is required. Therefore, in this research, applicable mesh structures for medical stents based on the design concepts of high strength, high flexibility are interested to solve various problem of conventional stent. According to the shape and dimensions of SFA occlusion therapy stent and indwelling delivery catheter, shape design of the meshed stent are performed using 3-dimensional CAD software Solid Works first. Then analytical examination on storage characteristics and compression characteristics of such mesh structure applied stent models were carried out through finite element analysis software ANSYS Workbench. Meshed stent models with higher strength and higher flexibility with integral molding are investigated analytically. It was found that the storage characteristics and compression characteristics of meshed stent modles are highly dependent on the basic mesh shapes with same surface void ratio. Trade-off relationship between flexibility and storage characteristics is found exited, it is required to provide appropriate curvatures during basic mesh shape design.

  18. Selective laser vaporization of polypropylene sutures and mesh

    Science.gov (United States)

    Burks, David; Rosenbury, Sarah B.; Kennelly, Michael J.; Fried, Nathaniel M.

    2012-02-01

    Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI. A compact, 7 Watt, 647-nm, red diode laser was operated with a radiant exposure of 81 J/cm2, pulse duration of 100 ms, and 1.0-mm-diameter laser spot. The 647-nm wavelength was selected because its absorption by water, hemoglobin, and other major tissue chromophores is low, while polypropylene absorption is high. Laser vaporization of ~200-μm-diameter polypropylene suture/mesh strands, in contact with fresh urinary tissue samples, ex vivo, was performed. Non-contact temperature mapping of the suture/mesh samples with a thermal camera was also conducted. Photoselective vaporization of polypropylene suture and mesh using a single laser pulse was achieved with peak temperatures of 180 and 232 °C, respectively. In control (safety) studies, direct laser irradiation of tissue alone resulted in only a 1 °C temperature increase. Selective laser vaporization of polypropylene suture/mesh materials is feasible without significant thermal damage to tissue. This technique may be useful for SUI procedures requiring surgical revision.

  19. Reaction rates for reaction-diffusion kinetics on unstructured meshes

    Science.gov (United States)

    Hellander, Stefan; Petzold, Linda

    2017-02-01

    The reaction-diffusion master equation is a stochastic model often utilized in the study of biochemical reaction networks in living cells. It is applied when the spatial distribution of molecules is important to the dynamics of the system. A viable approach to resolve the complex geometry of cells accurately is to discretize space with an unstructured mesh. Diffusion is modeled as discrete jumps between nodes on the mesh, and the diffusion jump rates can be obtained through a discretization of the diffusion equation on the mesh. Reactions can occur when molecules occupy the same voxel. In this paper, we develop a method for computing accurate reaction rates between molecules occupying the same voxel in an unstructured mesh. For large voxels, these rates are known to be well approximated by the reaction rates derived by Collins and Kimball, but as the mesh is refined, no analytical expression for the rates exists. We reduce the problem of computing accurate reaction rates to a pure preprocessing step, depending only on the mesh and not on the model parameters, and we devise an efficient numerical scheme to estimate them to high accuracy. We show in several numerical examples that as we refine the mesh, the results obtained with the reaction-diffusion master equation approach those of a more fine-grained Smoluchowski particle-tracking model.

  20. Prosthetic bioabsorbable mesh for hiatal hernia repair during sleeve gastrectomy.

    Science.gov (United States)

    Clapp, Benjamin

    2013-01-01

    Laparoscopic sleeve gastrectomy has become a valuable primary bariatric operation. It has an acceptable complication profile and amount of weight loss. However, one of the most distressing complications to the patient is reflux postoperatively. There is thought to be a relationship between a hiatal hernia and postoperative reflux. There is disagreement on how to address a hiatal hernia intraoperatively, and the use of mesh is controversial. Our objectives were to examine the use of a prosthetic bioabsorbable mesh for repair of a large hiatal hernia during a sleeve gastrectomy and to examine the incidence of reflux and mesh-related complications in the near term. This is a case series of patients with hiatal hernia undergoing a primary sleeve gastrectomy. None of the patients had a previous hiatal hernia repair. Three patients with large hiatal hernias diagnosed preoperatively or intraoperatively were included. The hiatus of the diaphragm was repaired with a posterior crural closure, and a piece of prosthetic bioabsorbable mesh was placed posteriorly to reinforce the repair. There were 3 patients. The mean follow-up period was 12 months. There were no mesh-related complications. One of the patients needed to resume proton pump inhibitors to control reflux. The use of a prosthetic bioabsorbable mesh to repair a hiatal hernia simultaneously with a sleeve gastrectomy is safe. There were no mesh-related complications at 1 year.

  1. Reaction rates for reaction-diffusion kinetics on unstructured meshes.

    Science.gov (United States)

    Hellander, Stefan; Petzold, Linda

    2017-02-14

    The reaction-diffusion master equation is a stochastic model often utilized in the study of biochemical reaction networks in living cells. It is applied when the spatial distribution of molecules is important to the dynamics of the system. A viable approach to resolve the complex geometry of cells accurately is to discretize space with an unstructured mesh. Diffusion is modeled as discrete jumps between nodes on the mesh, and the diffusion jump rates can be obtained through a discretization of the diffusion equation on the mesh. Reactions can occur when molecules occupy the same voxel. In this paper, we develop a method for computing accurate reaction rates between molecules occupying the same voxel in an unstructured mesh. For large voxels, these rates are known to be well approximated by the reaction rates derived by Collins and Kimball, but as the mesh is refined, no analytical expression for the rates exists. We reduce the problem of computing accurate reaction rates to a pure preprocessing step, depending only on the mesh and not on the model parameters, and we devise an efficient numerical scheme to estimate them to high accuracy. We show in several numerical examples that as we refine the mesh, the results obtained with the reaction-diffusion master equation approach those of a more fine-grained Smoluchowski particle-tracking model.

  2. Transcolonic ventral wall hernia mesh fixation in a porcine model.

    Science.gov (United States)

    Fong, D G; Ryou, M; Pai, R D; Tavakkolizadeh, A; Rattner, D W; Thompson, C C

    2007-10-01

    A natural orifice transluminal endoscopic surgery (NOTES) approach to ventral wall hernia repair may represent a potentially less invasive alternative to current transabdominal surgical techniques. We aimed to investigate the feasibility of using transcolonic NOTES to deliver hernia repair mesh into the peritoneal cavity, as well as the ability to manipulate composite mesh and secure it to the abdominal wall. Five pigs weighing 20 to 25 kg were used in this feasibility study involving two acute and three survival experiments. A prototype mesh delivery system was used to transfer 1.5 - 2-cm x 2.5 - 3-cm pieces of composite hernia mesh into the peritoneal cavity. Neodymium magnets on a prototype control arm were used to help position the mesh by magnetically engaging previously placed endoscopic clips. Transfascial fixation of the mesh with 3-0 monofilament sutures was achieved using a 19-gauge hollow needle, pusher wire, and a suture tag system. Composite hernia mesh was successfully transferred and secured in 5/5 attempts. All three survival animals thrived for 14 days prior to elective sacrifice. At necropsy, the mesh sites were found to be well peritonealized without adhesions. Suture placement through the posterior fascia was confirmed in 10/12 sutures. Of these, four sutures were within the abdominal musculature, and two sutures were through the anterior fascia (transfascial). Transcolonic delivery, transcutaneous magnetic manipulation, and fixation of composite hernia mesh are technically feasible in a porcine model with animal survival. An effective suturing method that allows consistent anchoring through the anterior fascia would be preferred and may require the development of novel devices.

  3. Randomised clinical trial: conventional Lichtenstein vs. hernioplasty with self-adhesive mesh in bilateral inguinal hernia surgery.

    Science.gov (United States)

    Porrero, Jose L; Castillo, María J; Pérez-Zapata, Ana; Alonso, María T; Cano-Valderrama, Oscar; Quirós, Esther; Villar, Sol; Ramos, Beatriz; Sánchez-Cabezudo, Carlos; Bonachia, Oscar; Marcos, Alberto; Pérez, Brígido

    2015-10-01

    To compare the results of conventional Lichtenstein hernioplasty with polypropylene mesh (PLP) with a lightweight self-adhesive mesh (Parietene Progrip®; Covidien, Dublin, Ireland) (PPG) used in patients with bilateral inguinal hernia. Randomised clinical trial with 89 patients with a minimum follow-up of 1 year. Every patient had bilateral inguinal hernia and had both prostheses implanted randomly, one on each side. Early postoperative and chronic pain was evaluated using the visual analogue scale. Also recurrence rate and subjective evaluation of patients were analysed. Pain in the early postoperative period was inferior on the side where the self-adhesive mesh had been implanted (6.12 vs. 6.62, p=0.005 during the 1st postoperative day; 2.12 vs. 2.62, p=0.001 during the 7th postoperative day). Differences disappeared with the long-term evaluation (0.71 vs. 0.98, p=0.148 1 year after the surgery). The operative time was significantly shorter on the PPG mesh side (24.37 ± 5.1 in case of the PPG mesh and 29.66 ± 5.6 in case of the PLP mesh, p<0,001). Recurrence occurred in seven patients (7.8%), six of them (6.7%, CI 3.0-14.4) on the PPG mesh side and one (1.1%, CI 0.2-7.8) on the PLP side. These differences were not statistically significant (p=0.125) CONCLUSIONS: Although hernioplasty with self-adhesive mesh reduced early postoperative pain, this reduction was clinically irrelevant and it had no influence on chronic pain. There was a trend towards a higher recurrence rate when self-adhesive meshes were used, and although in this study differences were not statistically significant they should be confirmed in later studies using larger samples. Surgical procedures that do not need fixing sutures are promising, but further studies are needed before they become the gold standard of inguinal hernia repair.

  4. Expected Transmission Energy Route Metric for Wireless Mesh Senor Networks

    Directory of Open Access Journals (Sweden)

    YanLiang Jin

    2011-01-01

    Full Text Available Mesh is a network topology that achieves high throughput and stable intercommunication. With great potential, it is expected to be the key architecture of future networks. Wireless sensor networks are an active research area with numerous workshops and conferences arranged each year. The overall performance of a WSN highly depends on the energy consumption of the network. This paper designs a new routing metric for wireless mesh sensor networks. Results from simulation experiments reveal that the new metric algorithm improves the energy balance of the whole network and extends the lifetime of wireless mesh sensor networks (WMSNs.

  5. Multiphase flow of immiscible fluids on unstructured moving meshes

    DEFF Research Database (Denmark)

    Misztal, Marek Krzysztof; Erleben, Kenny; Bargteil, Adam

    2012-01-01

    In this paper, we present a method for animating multiphase flow of immiscible fluids using unstructured moving meshes. Our underlying discretization is an unstructured tetrahedral mesh, the deformable simplicial complex (DSC), that moves with the flow in a Lagrangian manner. Mesh optimization...... operations improve element quality and avoid element inversion. In the context of multiphase flow, we guarantee that every element is occupied by a single fluid and, consequently, the interface between fluids is represented by a set of faces in the simplicial complex. This approach ensures...

  6. Numerical Convergence of Discrete Exterior Calculus on Arbitrary Surface Meshes

    KAUST Repository

    Mohamed, Mamdouh S.

    2018-02-13

    Discrete exterior calculus (DEC) is a structure-preserving numerical framework for partial differential equations solution, particularly suitable for simplicial meshes. A longstanding and widespread assumption has been that DEC requires special (Delaunay) triangulations, which complicated the mesh generation process especially on curved surfaces. This paper presents numerical evidences demonstrating that this restriction is unnecessary. Convergence experiments are carried out for various physical problems using both Delaunay and non-Delaunay triangulations. Signed diagonal definition for the key DEC operator (Hodge star) is adopted. The errors converge as expected for all considered meshes and experiments. This relieves the DEC paradigm from unnecessary triangulation limitation.

  7. Isotropic 2D quadrangle meshing with size and orientation control

    KAUST Repository

    Pellenard, Bertrand

    2011-12-01

    We propose an approach for automatically generating isotropic 2D quadrangle meshes from arbitrary domains with a fine control over sizing and orientation of the elements. At the heart of our algorithm is an optimization procedure that, from a coarse initial tiling of the 2D domain, enforces each of the desirable mesh quality criteria (size, shape, orientation, degree, regularity) one at a time, in an order designed not to undo previous enhancements. Our experiments demonstrate how well our resulting quadrangle meshes conform to a wide range of input sizing and orientation fields.

  8. Discrete Surface Evolution and Mesh Deformation for Aircraft Icing Applications

    Science.gov (United States)

    Thompson, David; Tong, Xiaoling; Arnoldus, Qiuhan; Collins, Eric; McLaurin, David; Luke, Edward; Bidwell, Colin S.

    2013-01-01

    Robust, automated mesh generation for problems with deforming geometries, such as ice accreting on aerodynamic surfaces, remains a challenging problem. Here we describe a technique to deform a discrete surface as it evolves due to the accretion of ice. The surface evolution algorithm is based on a smoothed, face-offsetting approach. We also describe a fast algebraic technique to propagate the computed surface deformations into the surrounding volume mesh while maintaining geometric mesh quality. Preliminary results presented here demonstrate the ecacy of the approach for a sphere with a prescribed accretion rate, a rime ice accretion, and a more complex glaze ice accretion.

  9. Engagement of Metal Debris into a Gear Mesh

    Science.gov (United States)

    Handschuh, Robert F.; Krantz, Timothy L.

    2010-01-01

    A series of bench top experiments was conducted to determine the effects of metallic debris being dragged through meshing gear teeth. A test rig that is typically used to conduct contact fatigue experiments was used for these tests. Several sizes of drill material, shim stock, and pieces of gear teeth were introduced and then driven through the meshing region. The level of torque required to drive the "chip" through the gear mesh was measured. From the data gathered, chip size sufficient to jam the mechanism can be determined.

  10. Vertex Normals and Face Curvatures of Triangle Meshes

    KAUST Repository

    Sun, Xiang

    2016-08-12

    This study contributes to the discrete differential geometry of triangle meshes, in combination with discrete line congruences associated with such meshes. In particular we discuss when a congruence defined by linear interpolation of vertex normals deserves to be called a ʼnormal’ congruence. Our main results are a discussion of various definitions of normality, a detailed study of the geometry of such congruences, and a concept of curvatures and shape operators associated with the faces of a triangle mesh. These curvatures are compatible with both normal congruences and the Steiner formula.

  11. GAMER: GPU-accelerated Adaptive MEsh Refinement code

    Science.gov (United States)

    Schive, Hsi-Yu; Tsai, Yu-Chih; Chiueh, Tzihong

    2016-12-01

    GAMER (GPU-accelerated Adaptive MEsh Refinement) serves as a general-purpose adaptive mesh refinement + GPU framework and solves hydrodynamics with self-gravity. The code supports adaptive mesh refinement (AMR), hydrodynamics with self-gravity, and a variety of GPU-accelerated hydrodynamic and Poisson solvers. It also supports hybrid OpenMP/MPI/GPU parallelization, concurrent CPU/GPU execution for performance optimization, and Hilbert space-filling curve for load balance. Although the code is designed for simulating galaxy formation, it can be easily modified to solve a variety of applications with different governing equations. All optimization strategies implemented in the code can be inherited straightforwardly.

  12. Modeling study of mesh conductors and their electroluminescent devices

    Science.gov (United States)

    Hu, Bin; Li, Dapeng; Manandhar, Prakash; Fan, Qinguo; Kasilingam, Dayalan; Calvert, Paul

    2015-02-01

    Numerical models were established to correlate with the experimentally measured properties of mesh conductors previously developed through a combined process of dip coating carbon nanotubes and inkjet printing poly 3,4-ethylenedioxythiophene: poly styrene sulfonate. The electroluminescent (EL) devices assembled with such mesh conductors as front electrodes were modeled by commercially available finite element method software COMSOL Multiphysics. The modeling results are in agreement with those from the experiments and suggest that an optimized fiber arrangement is the key for further improving the performance of EL devices based on mesh conductors.

  13. Coordinate generation with precise controls over mesh properties

    Science.gov (United States)

    Eiseman, P. R.

    1982-01-01

    Powerful local controls have been developed for mesh generation with the class of multisurface coordinate transformations. The controls come from local piecewise linear interpolants, and the resulting coordinates have continuous first derivatives. At the boundaries, the mesh controls provide the capability of joining distinct coordinate systems together with continuous derivatives. Away from boundaries, a local region can be given a particular mesh form to model internal objects or to simplify a problem. Applications of the controls are illustrated with a sequence of two-dimensional examples. For simplicity, each is generated about a NACA0012 airfoil which is of unit length and with leading edge pointed in a negative x-direction.

  14. Prolene (mesh bulbourethral sling in male incontinence

    Directory of Open Access Journals (Sweden)

    Rakesh Kapoor

    2007-01-01

    Full Text Available Objective : We present our preliminary results of bulbar urethral sling (single bolster in treatment of postprostatectomy urinary incontinence (PPUI. Materials and Methods: From May 2003 to June 2005, six patients with postprostatectomy urinary incontinence (transurethral resection of prostate in five patients and after open prostatectomy in one patient underwent prolene mesh bulbar urethral sling surgery. Preoperative evaluation included physical examination, neurological assessment, stress cystogram and urethrocystoscopy. Urodynamic evaluation was done in all patients for abdominal leak point pressure and ruling out bladder pathology. Results : Urodynamic studies did not demonstrate bladder instability in any patient. Mean abdominal leak point pressure was 43cm of water (range 26-80 cm of water. Mean duration of hospital stay was 3.2 days. Follow-up ranged from 6-22 months. Four patients out of six patients were completely dry till their last follow-up. One patient developed mild stress incontinence after one year of the surgery and required use of one to two pads per day. Mean pad use after surgery was 0.6 pads per day in comparison to mean pad usage of 6.4 pads per day preoperatively. One patient was over-continent after the procedure and required clean intermittent catheterization till last follow-up (six months. Mean cost of the procedure was $ 350+15. Conclusion: Prolene bulbar urethral sling (single bolster is an economically effective option in patients with postprostatectomy urinary incontinence.

  15. Paraesophageal hernia repair with bifacial mesh

    Science.gov (United States)

    Ungureanu, S; Șipitco, N; Gladun, N; Lepadatu, C

    2016-01-01

    Abstract Background.The paraesophageal hiatus hernias (PHH) are relatively uncommon, but an increased incidence has been reported and they now account for 5–10% of all hiatus hernias. The surgical treatment is recommended for all the patients with this pathology because of high risk of complications: obstruction, incarceration, strangulation or perforation. The use of prostheses is recommended in the process of repairing the giant PHH because the main problem of this operation is the high rate of recurrence. Case presentation.The patient is a 44-year-old male with a large and symptomatic paraesophageal hernia. Diagnosis was confirmed by instrumental examination. An elective laparoscopic repair was carried out by using polypropylene bifacial anti adhesive synthetic mesh (Surgimesh XB Aspide Medical). The postoperative period passed without severe complications. Conclusions.The laparoscopic approach as a therapeutic option can be successfully used in the repair of paraesophageal hernia. A selective use based on clinical experience was recommended, as the technique appeared to be safe, and in case of large hiatus hernia with hiatal defect, greater than 5 cm, the application of synthetic material to minimize the recurrence rate was recommended. PMID:27974917

  16. Fair packet scheduling in Wireless Mesh Networks

    KAUST Repository

    Nawab, Faisal

    2014-02-01

    In this paper we study the interactions of TCP and IEEE 802.11 MAC in Wireless Mesh Networks (WMNs). We use a Markov chain to capture the behavior of TCP sessions, particularly the impact on network throughput due to the effect of queue utilization and packet relaying. A closed form solution is derived to numerically determine the throughput. Based on the developed model, we propose a distributed MAC protocol called Timestamp-ordered MAC (TMAC), aiming to alleviate the unfairness problem in WMNs. TMAC extends CSMA/CA by scheduling data packets based on their age. Prior to transmitting a data packet, a transmitter broadcasts a request control message appended with a timestamp to a selected list of neighbors. It can proceed with the transmission only if it receives a sufficient number of grant control messages from these neighbors. A grant message indicates that the associated data packet has the lowest timestamp of all the packets pending transmission at the local transmit queue. We demonstrate that a loose ordering of timestamps among neighboring nodes is sufficient for enforcing local fairness, subsequently leading to flow rate fairness in a multi-hop WMN. We show that TMAC can be implemented using the control frames in IEEE 802.11, and thus can be easily integrated in existing 802.11-based WMNs. Our simulation results show that TMAC achieves excellent resource allocation fairness while maintaining over 90% of maximum link capacity across a large number of topologies.

  17. Head Injuries in Soccer.

    Science.gov (United States)

    Myrick, Karen M

    2016-07-01

    Soccer is currently the most popular and fastest growing sport worldwide, with approximately 265 million registered soccer players existing around the world. The popularity of the sport, coupled with the high incidence of 18.8-21.5 head injuries per 1,000 player hours reported, make it essential that clinicians, coaches, and the athletes, have a solid understanding of head injuries. The successful rehabilitation of athletes with head injuries relies upon early and accurate identification strategies and implementation of appropriate return to play measures across all areas in the continuum of care. Soccer is a frequently played sport, and head injuries are common. Therefore, it is imperative that clinicians, coaches, and the athletes themselves have a solid understanding of head injury prevention, diagnosis, and treatment options. The purpose of this article was to provide rehabilitation nurses with current information regarding frequently occurring head injuries in the widespread sport of soccer. © 2015 Association of Rehabilitation Nurses.

  18. TMAC: Timestamp-Ordered MAC Protocol for Wireless Mesh Networks

    KAUST Repository

    Nawab, Faisal

    2011-05-01

    Wireless Mesh Networks (WMNs) have emerged to meet a need for a self-organized and self-configured multi-hop wireless network infrastructure. Low cost infrastructure and ease of deployment have made WMNs an attractive technology for last mile access. However, 802.11 based WMNs are subject to serious fairness issues. With backlogged TCP traffic, nodes which are two or more hops away from the gateway are subject to starvation, while the one-hop away node saturates the channel with its own local traffic. We study the interactions of TCP and IEEE 802.11 MAC in WMNs to aid us in understanding and overcoming the unfairness problem. We propose a Markov chain to capture the behavior of TCP sessions, particularly the impact on network throughput performance due to the effect of queue utilization and packet relaying. A closed form solution is derived to numerically derive the throughput. Based on the developed model, we propose a distributed MAC protocol called Timestamp-ordered MAC (TMAC), aiming to alleviate the unfairness problem in WMNs via a manipulative per-node scheduling mechanism which takes advantage of the age of each packet as a priority metric. Simulation is conducted to validate our model and to illustrate the fairness characteristics of TMAC. Our results show that TMAC achieves excellent resource allocation fairness while maintaining above 90% of maximum link capacity in parking lot and large grid topologies. Our work illuminates the factors affecting TCP fairness in WMNs. Our theoretical and empirical findings can be used in future research to develop more fairness-aware protocols for WMNs.

  19. Head and Neck

    DEFF Research Database (Denmark)

    Højgaard, Liselotte; Berthelsen, Anne Kiil; Loft, Annika

    2014-01-01

    Positron emission tomography (PET)/computed tomography with FDG of the head and neck region is mainly used for the diagnosis of head and neck cancer, for staging, treatment evaluation, relapse, and planning of surgery and radio therapy. This article is a practical guide of imaging techniques......, including a detailed protocol for FDG PET in head and neck imaging, physiologic findings, and pitfalls in selected case stories....

  20. Probing the mechanism of saccade-associated head movements through observations of head movement propensity and cognition in the elderly.

    Science.gov (United States)

    Thumser, Zachary C; Adams, Nancy L; Lerner, Alan J; Stahl, John S

    2010-05-01

    Humans may accomplish gaze shifts by eye-only saccades or combined eye-head saccades. The mechanisms that determine whether the head moves remain poorly understood. Many observations can be explained if phylogenetically ancient circuits generate eye-head saccades by default and frontal cerebral structures interrupt this synergy when eye-only saccades are preferable. Saccade-associated head movements have been reported to increase in the elderly. To test the hypothesis of frontal inhibition of head movements, we investigated whether the increase is associated with a decline in frontal cognitive function. We measured head movement tendencies and cognition in volunteers aged 61-80. Measures of head movement tendency included the customary range of eye eccentricity, customary range of head eccentricity, range of target eccentricities evoking predominantly eye-only saccades, and two measures of head amplitude variation as a function of target eccentricity. Cognitive measures encompassed verbal fluency, verbal memory, non-verbal memory, and executive function. There was no correlation between cognition and any measure of head movement tendency. We combined these elderly data with measurements of head movements in a group aged 21-67 and found mildly reduced, not increased, head movement tendencies with age. However, when confronted with a task that could be accomplished without moving the head, young subjects were more likely to cease all head movements. While inconclusive regarding the hypothesis of inhibition of saccade-associated head movements by cerebral structures, the results indicate the need to distinguish between mechanisms that define head movement tendencies and mechanisms that adapt head motion to the geometry of a specific task.

  1. Lateral Response Comparison of Unbonded Elastomeric Bearings Reinforced with Carbon Fiber Mesh and Steel

    Directory of Open Access Journals (Sweden)

    Ali Karimzadeh Naghshineh

    2015-01-01

    Full Text Available The vertical and horizontal stiffness used in design of bearings have been established in the last few decades. At the meantime, applicability of the theoretical approach developed to estimate vertical stiffness of the fiber-reinforced bearings has been verified in different academic studies. The suitability of conventional horizontal stiffness equation developed for elastomeric material, mainly for steel-reinforced elastomeric bearings, has not been tested in detail for use of fiber-reinforced elastomeric bearings. In this research, lateral response of fiber mesh-reinforced elastomeric bearings has been determined through experimental tests and the results have been compared by corresponding values pertaining to the steel-reinforced bearings. Within the test program, eight pairs of fiber mesh-reinforced bearings and eight pairs of steel-reinforced bearings are subjected to different levels of compressive stress and cyclic shear strains. Fiber-reinforced elastomeric bearings may be more favorable to be used in seismic regions due to lower horizontal stiffness that can result in mitigation of seismic forces for levels of 100% shear strain. Damping properties of these types of fiber mesh-reinforced bearings depend mostly on the selection of elastomeric material compounds. Suggestions have been made for the lateral response of fiber-reinforced elastomeric bearings. It has also been determined that the classical equation for lateral stiffness based on linear elastic behavior assumptions developed for elastomeric bearings does not always apply to the fiber-reinforced ones.

  2. Head-to-toe whole-body MRI in psoriatic arthritis, axial spondyloarthritis and healthy subjects: first steps towards global inflammation and damage scores of peripheral and axial joints.

    Science.gov (United States)

    Poggenborg, René Panduro; Pedersen, Susanne Juhl; Eshed, Iris; Sørensen, Inge Juul; Møller, Jakob M; Madsen, Ole Rintek; Thomsen, Henrik S; Østergaard, Mikkel

    2015-06-01

    By whole-body MRI (WBMRI), we aimed to examine the frequency and distribution of inflammatory and structural lesions in PsA patients, SpA patients and healthy subjects (HSs), to introduce global WBMRI inflammation/damage scores, and to assess WBMRI's reproducibility and correlation with conventional MRI (convMRI). WBMRI (3.0-T) of patients with peripheral PsA (n = 18) or axial SpA (n = 18) and of HS (n = 12) was examined for proportion of evaluable features (readability) and the presence and pattern of lesions in axial and peripheral joints. Furthermore, global WBMRI scores of inflammation and structural damage were constructed, and WBMRI findings were compared with clinical measures and convMRI (SpA/HS: spine and SI joints; PsA/HS: hand). The readability (92-100%) and reproducibility (intrareader intraclass correlation coefficient: 0.62-1.0) were high in spine/SI joint, but lower in the distal peripheral joints. Wrists, shoulders, knees, ankles and MTP joints were most commonly involved, with frequency of synovitis > bone marrow oedema (BMO) > erosion. WBMRI global BMO scores of peripheral and axial joints were higher in PsA {median 7 [interquartile range (IQR) 3-15]} and SpA [8 (IQR 2-14)] than in HSs [2.5 (IQR 1-4.5)], both P joint scores were ρ = 0.20-0.78. WBMRI allows simultaneous assessment of peripheral and axial joints in PsA and SpA, and the distribution of inflammatory and structural lesions and global scores can be determined. The study strongly encourages further development and longitudinal testing of WBMRI techniques and assessment methods in PsA and SpA. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Link Conditions for Simplifying Meshes with Embedded Structures.

    Science.gov (United States)

    Thomas, Dilip Mathew; Natarajan, Vijay; Bonneau, Georges-Pierre

    2011-07-01

    Interactive visualization applications benefit from simplification techniques that generate good-quality coarse meshes from high-resolution meshes that represent the domain. These meshes often contain interesting substructures, called embedded structures, and it is desirable to preserve the topology of the embedded structures during simplification, in addition to preserving the topology of the domain. This paper describes a proof that link conditions, proposed earlier, are sufficient to ensure that edge contractions preserve the topology of the embedded structures and the domain. Excluding two specific configurations, the link conditions are also shown to be necessary for topology preservation. Repeated application of edge contraction on an extended complex produces a coarser representation of the domain and the embedded structures. An extension of the quadric error metric is used to schedule edge contractions, resulting in a good-quality coarse mesh that closely approximates the input domain and the embedded structures.

  4. Form-finding with polyhedral meshes made simple

    KAUST Repository

    Tang, Chengcheng

    2014-07-27

    We solve the form-finding problem for polyhedral meshes in a way which combines form, function and fabrication; taking care of user-specified constraints like boundary interpolation, planarity of faces, statics, panel size and shape, enclosed volume, and last, but not least, cost. Our main application is the interactive modeling of meshes for architectural and industrial design. Our approach can be described as guided exploration of the constraint space whose algebraic structure is simplified by introducing auxiliary variables and ensuring that constraints are at most quadratic. Computationally, we perform a projection onto the constraint space which is biased towards low values of an energy which expresses desirable "soft" properties like fairness. We have created a tool which elegantly handles difficult tasks, such as taking boundary-alignment of polyhedral meshes into account, planarization, fairing under planarity side conditions, handling hybrid meshes, and extending the treatment of static equilibrium to shapes which possess overhanging parts.

  5. RSW Fully Tet Coarse Cell-Centered Mesh

    Data.gov (United States)

    National Aeronautics and Space Administration — This is the RSW fully tetrahedral unstructured mesh dataset for a cell-centered code, including the viscous wind tunnel wall. UG3 : Grid File Name =...

  6. Application-specific mesh-based heterogeneous FPGA architectures

    CERN Document Server

    Parvez, Husain

    2011-01-01

    This volume presents a new exploration environment for mesh-based, heterogeneous FPGA architectures. Readers will find a description of state-of-the-art techniques for reducing area requirements, which both increase performance and enable power reduction.

  7. ARC Code TI: Middleware Using Existing SSH Hosts (Mesh)

    Data.gov (United States)

    National Aeronautics and Space Administration — Mesh is a secure, lightweight grid middleware that is based on the addition of a single sign-on capability to the built-in public key authentication mechanism of SSH...

  8. Mesh considerations for finite element blast modelling in biomechanics.

    Science.gov (United States)

    Panzer, Matthew B; Myers, Barry S; Bass, Cameron R

    2013-01-01

    Finite element (FE) modelling is a popular tool for studying human body response to blast exposure. However, blast modelling is a complex problem owing to more numerous fluid-structure interactions (FSIs) and the high-frequency loading that accompanies blast exposures. This study investigates FE mesh design for blast modelling using a sphere in a closed-ended shock tube meshed with varying element sizes using both tetrahedral and hexahedral elements. FSI was consistent for sphere-to-fluid element ratios between 0.25 and 4, and acceleration response was similar for both element types (R(2) = 0.997). Tetrahedral elements were found to become increasingly volatile following shock loading, causing higher pressures and stresses than predicted with the hexahedral elements. Deviatoric stress response was dependent on the sphere mesh size (p tube mesh size (p blast models.

  9. RSW Mixed Element Cell-Centered Medium Mesh

    Data.gov (United States)

    National Aeronautics and Space Administration — This RSW gridset is designed as the medium size mixed element grid for use with cell-centered unstructured meshes. UG3 : Grid File Name = rsw_med_mixedcc.b8.ugrid...

  10. AN ALGORITHM FOR PARALLEL SN SWEEPS ON UNSTRUCTURED MESHES

    Energy Technology Data Exchange (ETDEWEB)

    S. D. PAUTZ

    2000-12-01

    We develop a new algorithm for performing parallel S{sub n} sweeps on unstructured meshes. The algorithm uses a low-complexity list ordering heuristic to determine a sweep ordering on any partitioned mesh. For typical problems and with ''normal'' mesh partitionings we have observed nearly linear speedups on up to 126 processors. This is an important and desirable result, since although analyses of structured meshes indicate that parallel sweeps will not scale with normal partitioning approaches, we do not observe any severe asymptotic degradation in the parallel efficiency with modest ({le}100) levels of parallelism. This work is a fundamental step in the development of parallel S{sub n} methods.

  11. A Multicenter Noncomparative Clinical Study on Midface Rejuvenation Using a Nonabsorbable Polypropylene Mesh: Evaluation of Efficacy and Safety

    Directory of Open Access Journals (Sweden)

    Chang Sik Pak

    2015-09-01

    Full Text Available BackgroundFacial rejuvenation can be achieved using a variety of techniques. Since minimally invasive procedures for face lifting have become popular because of their convenience and short operating time, numerous minimally invasive surgical procedures have been developed. In this study, a nonabsorbable polypropylene mesh is introduced as a new face lifting instrument, with the nasolabial fold as the main target area. In this paper, we report the efficacy and safety of a polypropylene mesh in midface rejuvenation.MethodsThirty-three subjects with moderate-to-severe nasolabial folds were enrolled from two medical institutions for a noncomparative single-sample study. A mesh was inserted above the superficial muscular aponeurotic system layer, reaching the nasolabial folds through a temporal scalp incision. After 3 weeks, the temporal end of the mesh was pulled to provide a lifting effect. Then, the mesh was fixed to the deep temporal fascia using nonabsorbable sutures. To evaluate efficacy, we compared the scores on the Wrinkle Severity Rating Scale and a visual analog scale for patient satisfaction between the baseline and 7 weeks postoperatively. In addition, we evaluated safety based on the incidence of adverse events.ResultsThe treatment was deemed effective at improving wrinkles in 23 of 28 cases, and patient satisfaction improved significantly during the study period. There were seven cases of skin or subcutaneous tissue complications, including edema and erythema, but there were no suspected serious adverse events.ConclusionsFace lifting using a nonabsorbable mesh can improve nasolabial folds without serious adverse effects. Thus, this technique is safe and effective for midface rejuvenation.

  12. A Multicenter Noncomparative Clinical Study on Midface Rejuvenation Using a Nonabsorbable Polypropylene Mesh: Evaluation of Efficacy and Safety.

    Science.gov (United States)

    Pak, Chang Sik; Chang, Lan Sook; Lee, Hobin; Jeong, Jae Hoon; Jeong, Jinwook; Yoon, Eul-Sik; Heo, Chan Yeong

    2015-09-01

    Facial rejuvenation can be achieved using a variety of techniques. Since minimally invasive procedures for face lifting have become popular because of their convenience and short operating time, numerous minimally invasive surgical procedures have been developed. In this study, a nonabsorbable polypropylene mesh is introduced as a new face lifting instrument, with the nasolabial fold as the main target area. In this paper, we report the efficacy and safety of a polypropylene mesh in midface rejuvenation. Thirty-three subjects with moderate-to-severe nasolabial folds were enrolled from two medical institutions for a noncomparative single-sample study. A mesh was inserted above the superficial muscular aponeurotic system layer, reaching the nasolabial folds through a temporal scalp incision. After 3 weeks, the temporal end of the mesh was pulled to provide a lifting effect. Then, the mesh was fixed to the deep temporal fascia using nonabsorbable sutures. To evaluate efficacy, we compared the scores on the Wrinkle Severity Rating Scale and a visual analog scale for patient satisfaction between the baseline and 7 weeks postoperatively. In addition, we evaluated safety based on the incidence of adverse events. The treatment was deemed effective at improving wrinkles in 23 of 28 cases, and patient satisfaction improved significantly during the study period. There were seven cases of skin or subcutaneous tissue complications, including edema and erythema, but there were no suspected serious adverse events. Face lifting using a nonabsorbable mesh can improve nasolabial folds without serious adverse effects. Thus, this technique is safe and effective for midface rejuvenation.

  13. Enhancing the MeSH thesaurus to retrieve French online health resources in a quality-controlled gateway.

    Science.gov (United States)

    Douyère, Magaly; Soualmia, Lina F; Névéol, Aurélie; Rogozan, Alexandrina; Dahamna, Badisse; Leroy, Jean-Philippe; Thirion, Benoît; Darmoni, Stefan J

    2004-12-01

    The amount of health information available on the Internet is considerable. In this context, several health gateways have been developed. Among them, CISMeF (Catalogue and Index of Health Resources in French) was designed to catalogue and index health resources in French. The goal of this article is to describe the various enhancements to the MeSH thesaurus developed by the CISMeF team to adapt this terminology to the broader field of health Internet resources instead of scientific articles for the medline bibliographic database. CISMeF uses two standard tools for organizing information: the MeSH thesaurus and several metadata element sets, in particular the Dublin Core metadata format. The heterogeneity of Internet health resources led the CISMeF team to enhance the MeSH thesaurus with the introduction of two new concepts, respectively, resource types and metaterms. CISMeF resource types are a generalization of the publication types of medline. A resource type describes the nature of the resource and MeSH keyword/qualifier pairs describe the subject of the resource. A metaterm is generally a medical specialty or a biological science, which has semantic links with one or more MeSH keywords, qualifiers and resource types. The CISMeF terminology is exploited for several tasks: resource indexing performed manually, resource categorization performed automatically, visualization and navigation through the concept hierarchies and information retrieval using the Doc'CISMeF search engine. The CISMeF health gateway uses several MeSH thesaurus enhancements to optimize information retrieval, hierarchy navigation and automatic indexing.

  14. Native tissue repairs in anterior vaginal prolapse surgery: examining definitions of surgical success in the mesh era.

    Science.gov (United States)

    Lee, Una; Wolff, Erika M; Kobashi, Kathleen C

    2012-07-01

    Native tissue repair of the anterior vaginal wall was thought to have a poor success rate based on anatomic outcome. This high rate of anatomic failure was often quoted as the underlying reason for performing mesh-augmented prolapse repair. The purpose of this article is to review the outcomes of native tissue repair of anterior vaginal prolapse repair in the mesh era. Success in pelvic organ prolapse surgery has been redefined. The contemporary definition of success includes the absence of symptoms associated with a vaginal bulge, which correlates best with a patient's perception of success. When this concept is applied to 12 randomized controlled trials that compared native tissue anterior colporrhaphy and mesh repairs for anterior vaginal wall prolapse, it is apparent that although mesh repair had superior anatomic success (38-93 vs. 27-71%), both mesh and native tissue repair had excellent rates of symptomatic success (75-96 and 62-100%, respectively). Taken together, the overall reoperation rate for native tissue repair was 5.0% compared with 9.0% for mesh-augmented repair. Although anatomic stage 0 results are not achieved in many cases, patients do experience symptomatic relief and improvement in their quality of life, only seeking retreatment in a small proportion of cases with anatomic recurrence. Thus, the definition of success must include subjective symptom-based outcome in addition to anatomic outcome. In addition, the degree of later complications, including additional surgeries, must also be taken into account when defining success based on patient satisfaction.

  15. Finite element meshing approached as a global minimization process

    Energy Technology Data Exchange (ETDEWEB)

    WITKOWSKI,WALTER R.; JUNG,JOSEPH; DOHRMANN,CLARK R.; LEUNG,VITUS J.

    2000-03-01

    The ability to generate a suitable finite element mesh in an automatic fashion is becoming the key to being able to automate the entire engineering analysis process. However, placing an all-hexahedron mesh in a general three-dimensional body continues to be an elusive goal. The approach investigated in this research is fundamentally different from any other that is known of by the authors. A physical analogy viewpoint is used to formulate the actual meshing problem which constructs a global mathematical description of the problem. The analogy used was that of minimizing the electrical potential of a system charged particles within a charged domain. The particles in the presented analogy represent duals to mesh elements (i.e., quads or hexes). Particle movement is governed by a mathematical functional which accounts for inter-particles repulsive, attractive and alignment forces. This functional is minimized to find the optimal location and orientation of each particle. After the particles are connected a mesh can be easily resolved. The mathematical description for this problem is as easy to formulate in three-dimensions as it is in two- or one-dimensions. The meshing algorithm was developed within CoMeT. It can solve the two-dimensional meshing problem for convex and concave geometries in a purely automated fashion. Investigation of the robustness of the technique has shown a success rate of approximately 99% for the two-dimensional geometries tested. Run times to mesh a 100 element complex geometry were typically in the 10 minute range. Efficiency of the technique is still an issue that needs to be addressed. Performance is an issue that is critical for most engineers generating meshes. It was not for this project. The primary focus of this work was to investigate and evaluate a meshing algorithm/philosophy with efficiency issues being secondary. The algorithm was also extended to mesh three-dimensional geometries. Unfortunately, only simple geometries were tested

  16. On Mesh Editing, Manifold Learning, and Diffusion Wavelets

    Science.gov (United States)

    Rustamov, R. M.

    We spell out a formal equivalence between the naive Laplacian editing and semi-supervised learning by bi-Laplacian Regularized Least Squares. This allows us to write the solution to Laplacian mesh editing in a ‘closed’ form, based on which we introduce the Generalized Linear Editing (GLE). GLE has both naive Laplacian editing and gradient based editing as special cases. GLE allows using diffusion wavelets for mesh editing. We present preliminary experiments, and shortly discuss connections to segmentation.

  17. Unstructured finite element mesh generation and adaptive procedures for CFD

    Science.gov (United States)

    Peraire, J.; Morgan, K.; Peiro, J.

    1990-01-01

    A method is described for generating unstructured meshes of triangles or tetrahedra for computational domains of complex geometrical shape. To illustrate the power of the approach, it is applied to the solution of flows past several complete aircraft configurations. The advocated approach allows for the natural incorporation of mesh adaptivity and this is demonstrated for both inviscid and viscous computations in two and three dimensions.

  18. Fibrin sealant for mesh fixation in laparoscopic umbilical hernia repair

    DEFF Research Database (Denmark)

    Eriksen, J R; Bisgaard, T; Assaadzadeh, S

    2013-01-01

    Fibrin sealant for mesh fixation has significant positive effects on early outcome after laparoscopic ventral hernia repair (LVHR) compared with titanium tacks. Whether fibrin sealant fixation also results in better long-term outcome is unknown.......Fibrin sealant for mesh fixation has significant positive effects on early outcome after laparoscopic ventral hernia repair (LVHR) compared with titanium tacks. Whether fibrin sealant fixation also results in better long-term outcome is unknown....

  19. Estimation of Expectable Network Quality in Wireless Mesh Networks

    OpenAIRE

    Wollenberg, Till

    2012-01-01

    Part 3: Computing in Networks; International audience; Our work aims to improve the usability of wireless mesh networks as communication layer of smart office environments. While wireless mesh networks are well-suited for this task in general, the negative impact of interference, fading, and saturation makes the communication basically opportunistic. Our goal is to develop a system which allows a short-term estimation of network quality in terms of throughput, packet loss and latency. The est...

  20. Incisional hernia prevention using a cyanoacrilate-fixed retrofascial mesh.

    Science.gov (United States)

    Hoyuela, Carlos; Juvany, Montserrat; Trias, Miquel; Ardid, Jordi; Martrat, Antoni

    2018-01-01

    The rate of incisional hernia in high-risk patients (obesity, cancer, etc.) is high, even in laparoscopic surgery. The aim of this study is to evaluate the safety of the use of cyanoacrylate fixed prophylactic meshes in the assistance incision in overweight or obese patients undergoing laparoscopic colorectal surgery. A prospective, non-randomized cohort study of patients undergoing elective laparoscopic resection for colorectal cancer between January 2013 and March 2016 was performed. Those with a body mass index greater than 25kg / m 2 were evaluated to implant a prophylactic meshes fixed with cyanoacrylate (Histoacryl®) as reinforcement of the assistance incision. 52 patients were analyzed (mean body mass index: 28.4±2kg / m 2 ). Prophylactic meshes was implanted in 15 patients. The time to put the mesh in place was always less than 5minutes. There was no significant difference in wound infection rate (12% vs. 10%). No mesh had to be explanted. Although the mean follow-up was shorter (14.1±4 vs. 22.3±9 months), there were no incisional hernia in the mesh group. On the other hand, in the non-mesh group, 1 acute evisceration (2.7%) and 4 incisional hernia of the assistance incision were observed (10.8%). There were no significant differences between groups regarding trocar incisional hernia (6.6 vs. 5.4%). The implantation of a reinforcement prophylactic mesh in overweight or obese patients undergoing laparoscopic colorectal surgery is safe and seems to reduce the short-term rate of incisional hernia. Fixation with cyanoacrylate is a rapid method that facilitates the procedure without additional complications. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Is vaginal mesh a stimulus of autoimmune disease?

    Science.gov (United States)

    Chughtai, Bilal; Sedrakyan, Art; Mao, Jialin; Eilber, Karyn S; Anger, Jennifer T; Clemens, J Quentin

    2017-05-01

    Polypropylene mesh has been used as a means of reinforcing weak tissues in women with pelvic organ prolapse and stress urinary incontinence. We sought to investigate a potential link between the development of systemic/autoimmune disorders and synthetic polypropylene mesh repairs. New York State Department of Health Statewide Planning and Research Cooperative System data were utilized to conduct this retrospective cohort study. Adult women undergoing surgery for pelvic organ prolapse with vaginally implanted mesh from January 2008 through December 2009 in inpatient and ambulatory surgery settings in New York State were identified. Two separate control cohorts were created to compare outcomes, including a screening colonoscopy cohort and a vaginal hysterectomy cohort for benign gynecologic conditions (without pelvic organ prolapse repair or sling). Patients in the mesh cohort were individually matched to the control cohorts based on demographics, comorbidities, and procedure date. The development of systemic/autoimmune disease was determined before and after matching for 1-year, 2-year, 3-year, and entire follow-up (up to 6 years until December 2014) and differences between groups were evaluated. A total of 2102 patients underwent mesh-based pelvic organ prolapse surgery from January 2008 through December 2009. In the control cohorts, 37,298 patients underwent colonoscopy and 7338 underwent vaginal hysterectomy. When patients were matched based on demographics, comorbidities, and procedure time, mesh-based surgery was not associated with an increased risk of developing autoimmune disease at any of the evaluated time periods. Mesh-based vaginal surgery was not associated with the development of systemic/autoimmune diseases. These data refute claims against mesh as a cause of systemic disease. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Pubovaginal sling with a low-cost polypropylene mesh

    OpenAIRE

    Fransber R. Rodrigues; Romulo Maroccolo Filho; Maroccolo,Roberto R.; Paiva,Lucio C.; Diaz,Fernando A.; Ribeiro,Eduardo C.

    2007-01-01

    OBJECTIVE: The aim of this study was to present the results of pubovaginal sling with a low-cost polypropylene mesh in the treatment of stress urinary incontinence MATERIALS AND METHODS: 118 women diagnosed with stress urinary incontinence (SUI) due to urethral hypermobility or intrinsic sphincteric deficiency, treated with pubovaginal sling (PVS) with a low-cost polypropylene mesh confectioned by the surgeon, were analyzed. All patients had a basic evaluation that included a medical history,...

  3. Anisotropic adaptive mesh generation in two dimensions for CFD

    Energy Technology Data Exchange (ETDEWEB)

    Borouchaki, H.; Castro-Diaz, M.J.; George, P.L.; Hecht, F.; Mohammadi, B. [INRIA, Le Chesnay (France)

    1996-12-31

    This paper describes the extension of the classical Delaunay method in the case where anisotropic meshes are required such as in CFD when the modelized physic is strongly directional. The way in which such a mesh generation method can be incorporated in an adaptative loop of CFD as well as the case of multicriterium adaptation are discussed. Several concrete application examples are provided to illustrate the capabilities of the proposed method.

  4. Tangle-Free Mesh Motion for Ablation Simulations

    Science.gov (United States)

    Droba, Justin

    2016-01-01

    Problems involving mesh motion-which should not be mistakenly associated with moving mesh methods, a class of adaptive mesh redistribution techniques-are of critical importance in numerical simulations of the thermal response of melting and ablative materials. Ablation is the process by which material vaporizes or otherwise erodes due to strong heating. Accurate modeling of such materials is of the utmost importance in design of passive thermal protection systems ("heatshields") for spacecraft, the layer of the vehicle that ensures survival of crew and craft during re-entry. In an explicit mesh motion approach, a complete thermal solve is first performed. Afterwards, the thermal response is used to determine surface recession rates. These values are then used to generate boundary conditions for an a posteriori correction designed to update the location of the mesh nodes. Most often, linear elastic or biharmonic equations are used to model this material response, traditionally in a finite element framework so that complex geometries can be simulated. A simple scheme for moving the boundary nodes involves receding along the surface normals. However, for all but the simplest problem geometries, evolution in time following such a scheme will eventually bring the mesh to intersect and "tangle" with itself, inducing failure. This presentation demonstrates a comprehensive and sophisticated scheme that analyzes the local geometry of each node with help from user-provided clues to eliminate the tangle and enable simulations on a wide-class of difficult problem geometries. The method developed is demonstrated for linear elastic equations but is general enough that it may be adapted to other modeling equations. The presentation will explicate the inner workings of the tangle-free mesh motion algorithm for both two and three-dimensional meshes. It will show abstract examples of the method's success, including a verification problem that demonstrates its accuracy and

  5. Vaginal Approaches Using Synthetic Mesh to Treat Pelvic Organ Prolapse

    OpenAIRE

    Moon, Jei Won; Chae, Hee Dong

    2016-01-01

    Pelvic organ prolapse (POP) is a very common condition in elderly women. In women with POP, a sacrocolpopexy or a vaginal hysterectomy with anterior and posterior colporrhaphy has long been considered as the gold standard of treatment. However, in recent decades, the tendency to use a vaginal approach with mesh for POP surgery has been increasing. A vaginal approach using mesh has many advantages, such as its being less invasive than an abdominal approach and easier to do than a laparoscopic ...

  6. Mesh Copy/Move/Merge Tool for Reactor Simulation Applications

    Energy Technology Data Exchange (ETDEWEB)

    Tautges, Timothy J. [Argonne National Lab. (ANL), Argonne, IL (United States); Jain, Rajeev [Argonne National Lab. (ANL), Argonne, IL (United States)

    2014-04-30

    Reactor core simulations require the construction and mesh generation for core models consisting of lattices of fuel and other rods grouped into assemblies, and lattices of assemblies of several types grouped into a core model. A set of tools has been described for generating assembly and core lattice models. Both rectangular and hexagonal lattices are supported. The tools operate in three stages. First, assembly models of various types can be generated by the AssyGen tool, based on input describing the content of unit cells, the arrangement of unit cells in the lattice, and the extent of the lattice and any surrounding material. After generating the assembly model, the model is meshed with the CUBIT mesh generation toolkit, optionally based on a journal file output by AssyGen. After one or more assembly model meshes have been constructed, they are arranged in a core model using the CoreGen tool. The input for CoreGen is similar to that of AssyGen, with assembly models substituted for unit cells. AssyGen and CoreGen also annotate the models with material and volume groupings necessary for specifying materials and boundary conditions required by the analysis. The AssyGen and CoreGen tools are packaged in the open-source MeshKit library for mesh generation; download and build instructions are included in this document.

  7. Enriching Triangle Mesh Animations with Physically Based Simulation.

    Science.gov (United States)

    Li, Yijing; Xu, Hongyi; Barbic, Jernej

    2017-10-01

    We present a system to combine arbitrary triangle mesh animations with physically based Finite Element Method (FEM) simulation, enabling control over the combination both in space and time. The input is a triangle mesh animation obtained using any method, such as keyframed animation, character rigging, 3D scanning, or geometric shape modeling. The input may be non-physical, crude or even incomplete. The user provides weights, specified using a minimal user interface, for how much physically based simulation should be allowed to modify the animation in any region of the model, and in time. Our system then computes a physically-based animation that is constrained to the input animation to the amount prescribed by these weights. This permits smoothly turning physics on and off over space and time, making it possible for the output to strictly follow the input, to evolve purely based on physically based simulation, and anything in between. Achieving such results requires a careful combination of several system components. We propose and analyze these components, including proper automatic creation of simulation meshes (even for non-manifold and self-colliding undeformed triangle meshes), converting triangle mesh animations into animations of the simulation mesh, and resolving collisions and self-collisions while following the input.

  8. An Implementation and Parallelization of the Scale Space Meshing Algorithm

    Directory of Open Access Journals (Sweden)

    Julie Digne

    2015-11-01

    Full Text Available Creating an interpolating mesh from an unorganized set of oriented points is a difficult problemwhich is often overlooked. Most methods focus indeed on building a watertight smoothed meshby defining some function whose zero level set is the surface of the object. However in some casesit is crucial to build a mesh that interpolates the points and does not fill the acquisition holes:either because the data are sparse and trying to fill the holes would create spurious artifactsor because the goal is to explore visually the data exactly as they were acquired without anysmoothing process. In this paper we detail a parallel implementation of the Scale-Space Meshingalgorithm, which builds on the scale-space framework for reconstructing a high precision meshfrom an input oriented point set. This algorithm first smoothes the point set, producing asingularity free shape. It then uses a standard mesh reconstruction technique, the Ball PivotingAlgorithm, to build a mesh from the smoothed point set. The final step consists in back-projecting the mesh built on the smoothed positions onto the original point set. The result ofthis process is an interpolating, hole-preserving surface mesh reconstruction.

  9. 3D Mesh Compression and Transmission for Mobile Robotic Applications

    Directory of Open Access Journals (Sweden)

    Bailin Yang

    2016-01-01

    Full Text Available Mobile robots are useful for environment exploration and rescue operations. In such applications, it is crucial to accurately analyse and represent an environment, providing appropriate inputs for motion planning in order to support robot navigation and operations. 2D mapping methods are simple but cannot handle multilevel or multistory environments. To address this problem, 3D mapping methods generate structural 3D representations of the robot operating environment and its objects by 3D mesh reconstruction. However, they face the challenge of efficiently transmitting those 3D representations to system modules for 3D mapping, motion planning, and robot operation visualization. This paper proposes a quality-driven mesh compression and transmission method to address this. Our method is efficient, as it compresses a mesh by quantizing its transformed vertices without the need to spend time constructing an a-priori structure over the mesh. A visual distortion function is developed to govern the level of quantization, allowing mesh transmission to be controlled under different network conditions or time constraints. Our experiments demonstrate how the visual quality of a mesh can be manipulated by the visual distortion function.

  10. Gentamicin supplementation of polyvinylidenfluoride mesh materials for infection prophylaxis.

    Science.gov (United States)

    Junge, Karsten; Rosch, Raphael; Klinge, Uwe; Krones, Carsten; Klosterhalfen, Bernd; Mertens, Peter R; Lynen, Petra; Kunz, Dagmar; Preiss, Achim; Peltroche-Llacsahuanga, Heidrun; Schumpelick, Volker

    2005-03-01

    Hernia repair evolved from pure tissue repair to mesh repair due to decreased recurrence rates. However, concern exists about mesh-related infections occurring even several years after initial operation. Therefore, a polyvinylidenfluoride (PVDF) mesh material was constructed and surface modified by plasma-induced graft polymerization of acrylic acid (PVDF+PAAc). Antimicrobial treatment was sought by binding of gentamicin (PVDF+PAAc+Gentamicin). In vitro efficacy and cytotoxicity was measured by agar diffusion test, L929 cytotoxicity testing and by analyzing the amount of gentamicin release from the mesh surface. In vivo biocompatibility was evaluated in 45 Sprague-Dawley rats. 7, 21 and 90 days after mesh implantation the amount of inflammatory and connective tissue as well as the percentage of proliferating (Ki67) and apoptotic cells (TUNEL) were analyzed at the perifilamentary region. Agar diffusion tests showed sufficient local antimicrobiotic effects against the bacteria tested after 24h of incubation. No signs of cytotoxicity could be identified by L929 testing. Furthermore, surface modification did not affect the in vivo biocompatibility. At the end of the observation period, no significant differences were found for the perifilamentary amount of inflammatory cells and connective tissue and the percentage of Ki67 and TUNEL positive stained cells. The presented data confirm that an antibiotic surface modification of PVDF mesh samples is feasible. By analyzing cytotoxicity in vitro as well as biocompatibility in vivo no side effects were observed.

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  12. Head Injuries in Children

    Science.gov (United States)

    Pennington, Nicole

    2010-01-01

    School nurses play a crucial role in injury prevention and initial treatment when injuries occur at school. The role of school nurses includes being knowledgeable about the management of head injuries, including assessment and initial treatment. The school nurse must be familiar with the outcomes of a head injury and know when further evaluation…

  13. Abnormal Head Position

    Science.gov (United States)

    ... non-ocular causes of an abnormal head position? Congenital shortening of the neck muscles (sternocleidomastoid) can cause a head tilt. This is ... amblyopia) are other treatment alternatives. Physical therapy helps congenital torticollis from tight neck muscles. Updated ... Terms & Conditions Most Common ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside of ...

  15. Head Start in Action.

    Science.gov (United States)

    Riley, Clara M. D.; Epps, Frances M. J.

    Records and observations from a summer Head Start program, conducted in Los Angeles by Delta Sigma Theta, are delineated in this book. It relates firsthand experiences of the participating personnel as they developed and implemented a Head Start program for some 300 children. The book is divided into three sections. Section I,…

  16. Combined in vivo and ex vivo analysis of mesh mechanics in a porcine hernia model.

    Science.gov (United States)

    Kahan, Lindsey G; Lake, Spencer P; McAllister, Jared M; Tan, Wen Hui; Yu, Jennifer; Thompson, Dominic; Brunt, L Michael; Blatnik, Jeffrey A

    2017-07-21

    Hernia meshes exhibit variability in mechanical properties, and their mechanical match to tissue has not been comprehensively studied. We used an innovative imaging model of in vivo strain tracking and ex vivo mechanical analysis to assess effects of mesh properties on repaired abdominal walls in a porcine model. We hypothesized that meshes with dissimilar mechanical properties compared to native tissue would alter abdominal wall mechanics more than better-matched meshes. Seven mini-pigs underwent ventral hernia creation and subsequent open repair with one of two heavyweight polypropylene meshes. Following mesh implantation with attached radio-opaque beads, fluoroscopic images were taken at insufflation pressures from 5 to 30 mmHg on postoperative days 0, 7, and 28. At 28 days, animals were euthanized and ex vivo mechanical testing performed on full-thickness samples across repaired abdominal walls. Testing was conducted on 13 mini-pig controls, and on meshes separately. Stiffness and anisotropy (the ratio of stiffness in the transverse versus craniocaudal directions) were assessed. 3D reconstructions of repaired abdominal walls showed stretch patterns. As pressure increased, both meshes expanded, with no differences between groups. Over time, meshes contracted 17.65% (Mesh A) and 0.12% (Mesh B; p = 0.06). Mesh mechanics showed that Mesh A deviated from anisotropic native tissue more than Mesh B. Compared to native tissue, Mesh A was stiffer both transversely and craniocaudally. Explanted repaired abdominal walls of both treatment groups were stiffer than native tissue. Repaired tissue became less anisotropic over time, as mesh properties prevailed over native abdominal wall properties. This technique assessed 3D stretch at the mesh level in vivo in a porcine model. While the abdominal wall expanded, mesh-ingrown areas contracted, potentially indicating stresses at mesh edges. Ex vivo mechanics demonstrate that repaired tissue adopts mesh properties, suggesting

  17. Biomechanical analyses of prosthetic mesh repair in a hiatal hernia model.

    Science.gov (United States)

    Alizai, Patrick Hamid; Schmid, Sofie; Otto, Jens; Klink, Christian Daniel; Roeth, Anjali; Nolting, Jochen; Neumann, Ulf Peter; Klinge, Uwe

    2014-10-01

    Recurrence rate of hiatal hernia can be reduced with prosthetic mesh repair; however, type and shape of the mesh are still a matter of controversy. The purpose of this study was to investigate the biomechanical properties of four conventional meshes: pure polypropylene mesh (PP-P), polypropylene/poliglecaprone mesh (PP-U), polyvinylidenefluoride/polypropylene mesh (PVDF-I), and pure polyvinylidenefluoride mesh (PVDF-S). Meshes were tested either in warp direction (parallel to production direction) or perpendicular to the warp direction. A Zwick testing machine was used to measure elasticity and effective porosity of the textile probes. Stretching of the meshes in warp direction required forces that were up to 85-fold higher than the same elongation in perpendicular direction. Stretch stress led to loss of effective porosity in most meshes, except for PVDF-S. Biomechanical impact of the mesh was additionally evaluated in a hiatal hernia model. The different meshes were used either as rectangular patches or as circular meshes. Circular meshes led to a significant reinforcement of the hiatus, largely unaffected by the orientation of the warp fibers. In contrast, rectangular meshes provided a significant reinforcement only when warp fibers ran perpendicular to the crura. Anisotropic elasticity of prosthetic meshes should therefore be considered in hiatal closure with rectangular patches. © 2014 Wiley Periodicals, Inc.

  18. Porcine head response to blast.

    Science.gov (United States)

    Shridharani, Jay K; Wood, Garrett W; Panzer, Matthew B; Capehart, Bruce P; Nyein, Michelle K; Radovitzky, Raul A; Bass, Cameron R 'dale'

    2012-01-01

    Recent studies have shown an increase in the frequency of traumatic brain injuries related to blast exposure. However, the mechanisms that cause blast neurotrauma are unknown. Blast neurotrauma research using computational models has been one method to elucidate that response of the brain in blast, and to identify possible mechanical correlates of injury. However, model validation against experimental data is required to ensure that the model output is representative of in vivo biomechanical response. This study exposes porcine subjects to primary blast overpressures generated using a compressed-gas shock tube. Shock tube blasts were directed to the unprotected head of each animal while the lungs and thorax were protected using ballistic protective vests similar to those employed in theater. The test conditions ranged from 110 to 740 kPa peak incident overpressure with scaled durations from 1.3 to 6.9 ms and correspond approximately with a 50% injury risk for brain bleeding and apnea in a ferret model scaled to porcine exposure. Instrumentation was placed on the porcine head to measure bulk acceleration, pressure at the surface of the head, and pressure inside the cranial cavity. Immediately after the blast, 5 of the 20 animals tested were apneic. Three subjects recovered without intervention within 30 s and the remaining two recovered within 8 min following respiratory assistance and administration of the respiratory stimulant doxapram. Gross examination of the brain revealed no indication of bleeding. Intracranial pressures ranged from 80 to 390 kPa as a result of the blast and were notably lower than the shock tube reflected pressures of 300-2830 kPa, indicating pressure attenuation by the skull up to a factor of 8.4. Peak head accelerations were measured from 385 to 3845 G's and were well correlated with peak incident overpressure (R(2) = 0.90). One SD corridors for the surface pressure, intracranial pressure (ICP), and head acceleration are

  19. SUBJECT INDEX

    Indian Academy of Sciences (India)

    Subject Index. Variation of surface electric field during geomagnetic disturbed period at Maitri, Antarctica. 1721. Geomorphology. A simple depression-filling method for raster and irregular elevation datasets. 1653. Decision Support System integrated with Geographic. Information System to target restoration actions in water-.

  20. On the subject-predicate relation and subject agreement in SiSwati ...

    African Journals Online (AJOL)

    The paper also argues that subject agreement is a purely syntactic phenomenon that takes place in a spec-head relationship. It proposes that subject agreement is triggered by verbs, and that multiple subject agreement within a clause occurs when auxiliary verbs iterate. The theoretical consequences of the analysis ...

  1. Non-contiguous processor allocation strategy for 2D mesh connected multicomputers based on sub-meshes available for allocation

    OpenAIRE

    Bani-Mohammad, S.; Ould-Khaoua, M.; Abaneh, I.; Mackenzie, L.M.

    2006-01-01

    Contiguous allocation of parallel jobs usually suffers from the degrading effects of fragmentation as it requires that the allocated processors be contiguous and has the same topology as the network topology connecting these processors. In non-contiguous allocation, a job can execute on multiple disjoint smaller sub-meshes rather than always waiting until a single sub-mesh of the requested size is available. Lifting the contiguity condition in non-contiguous allocation is expected to reduce p...

  2. Does mesh offer an advantage over tissue in the open repair of umbilical hernias? A systematic review and meta-analysis.

    Science.gov (United States)

    Aslani, N; Brown, C J

    2010-10-01

    To determine the best surgical approach for the open repair of primary umbilical hernias. Studies were identified through searching MEDLINE, EMBASE, and the Cochrane database, as well as hand-searching references. Randomized controlled trials (RCTs) and observational studies comparing mesh to suture repair for primary umbilical hernias published between January 1965 and October 2009 were included. Data regarding the recurrence rate, complications, number of subjects, length of follow-up, size of hernia, and type of mesh were extracted. Log odds ratios were calculated and weighed by the Mantel-Haenszel method to obtain a pooled estimate with 95% confidence interval (CI). A fixed effects model was used. Three RCTs and ten observational studies were identified. The pooled odds ratio (OR) for RCTs was 0.09 in favor of mesh (95% CI 0.02-0.39). The pooled OR for observational studies was 0.40 in favor of mesh (95% CI 0.21-0.75). There was no difference in complication rates between mesh and tissue repair in RCTs or observational studies. The use of mesh in umbilical hernia repair results in decreased recurrence and similar wound complications rates compared to tissue repair for primary umbilical hernias.

  3. Strategies to minimize adhesions to intraperitoneally placed mesh in laparoscopic ventral hernia repair.

    Science.gov (United States)

    Tran, Hanh; Saliba, Lucia; Chandratnam, Edward; Turingan, Isidro; Hawthorne, Wayne

    2012-01-01

    Adhesions to mesh/tacks in laparoscopic ventral hernia repair are often cited as reasons not to adopt its evidence-based superiority over conventional open methods. This pilot study assessed the occurrence of adhesions to full-sized Polypropylene and Gore-tex DualMesh Plus meshes and the possibility for adhesion prevention using fibrin sealant. Two 10-cm to 15-cm pieces of mesh were placed and fixed laparoscopically in pigs (25kg to 55kg). Group I: 2 animals with Polypropylene mesh on one side and DualMesh on other side. Group II: 2 animals with DualMesh on each side with fibrin sealant applied to the periphery of mesh and staples to one side. Group III: 1 animal with 2 pieces of Polypropylene mesh with fibrin sealant applied to the entire mesh. All animals underwent laparoscopy 3 months later to assess the extent of adhesions, and full-thickness specimens were removed for histological evaluation. More Polypropylene mesh was involved in adhesions than DualMesh. However, with the DualMesh involved in adhesions, more of the surface area was involved in forming adhesions than with Polypropylene mesh. None of the implanted DualMesh had visceral adhesions, while 2 out of 3 Polypropylene meshes had adhesions to both the liver and spleen but none to the bowel. Implanted Polypropylene mesh with fibrin sealant had no adhesions. DualMesh had shrunk more significantly than Polypropylene mesh. Histological evaluation showed absence of acute inflammatory response, significantly more chronic inflammatory response to DualMesh compared to Polypropylene and complete mesothelialization with both meshes. There was extensive collagen deposition between Polypropylene mesh fibers, while fibrosis occurred on both sides of DualMesh with synovial metaplasia over its peritoneal surface akin to encapsulation. DualMesh caused fewer omental and visceral adhesions than Polypropylene mesh did. Fibrin sealant eliminated adhesions to DualMesh and prevented adhesions to Polypropylene mesh when

  4. New strategies to improve results of mesh surgeries for vaginal prolapses repair – an update

    Directory of Open Access Journals (Sweden)

    Fernando Goulart Fernandes Dias

    2015-08-01

    Full Text Available ABSTRACTThe use of meshes has become the first option for the treatment of soft tissue disorders as hernias and stress urinary incontinence and widely used in vaginal prolapse's treatment. However, complications related to mesh issues cannot be neglected. Various strategies have been used to improve tissue integration of prosthetic meshes and reduce related complications. The aim of this review is to present the state of art of mesh innovations, presenting the whole arsenal which has been studied worldwide since composite meshes, coated meshes, collagen's derived meshes and tissue engineered prostheses, with focus on its biocompatibility and technical innovations, especially for vaginal prolapse surgery.

  5. Driving with head-slaved camera system

    NARCIS (Netherlands)

    Oving, A.B.; Erp, J.B.F. van

    2001-01-01

    In a field experiment, we tested the effectiveness of a head-slaved camera system for driving an armoured vehicle under armour. This system consists of a helmet-mounted display (HMD), a headtracker, and a motion platform with two cameras. Subjects performed several driving tasks on paved and in

  6. A comparative study of laparoscopic sacrocolpopexy and total vaginal mesh procedure using lightweight polypropylene meshes for prolapse repair.

    Science.gov (United States)

    Liu, Chih-Ku; Tsai, Ching-Pei; Chou, Min-Min; Shen, Pao-Sheng; Chen, Gin-Den; Hung, Yao-Ching; Hung, Man-Jung

    2014-12-01

    Use of vaginal meshes for treatment of pelvic organ prolapse (POP) remains controversial. A trend toward abdominal approaches and the development of new meshes has been noted. We compared the 1-year results of two different approaches using new lightweight meshes. Sixty-nine (95.8%) of 72 women with POP Stage ≥ 2, who underwent laparoscopic sacrocolpopexy (LSC) (n = 39) or a total vaginal mesh (TVM) procedure (n = 30) using lightweight polypropylene meshes, were studied. Baseline and follow-up assessments included a pelvic examination and a composite condition-specific questionnaire. A detailed comparison of 1-year outcomes was made. Data were analyzed using appropriate statistical methods. Compared to the TVM group, the LSC group was characterized by a younger age (53.7 years vs. 64.1 years, p polypropylene meshes seems to be safe and has comparable outcomes, but limitations may vary. Copyright © 2014. Published by Elsevier B.V.

  7. A Rare Complication of Composite Dual Mesh: Migration and Enterocutaneous Fistula Formation

    Directory of Open Access Journals (Sweden)

    Ozgur Bostanci

    2015-01-01

    Full Text Available Introduction. Mesh is commonly employed for abdominal hernia repair because it ensures a low recurrence rate. However, enterocutaneous fistula due to mesh migration can occur as a very rare, late complication, for which diagnosis is very difficult. Presentation of Case. Here we report the case of an enterocutaneous fistula due to late mesh migration in a mentally retarded, diabetic, 35-year-old male after umbilical hernia repair with composite dual mesh in 2010. Discussion. Mesh is a foreign substance, because of that some of the complications including hematoma, seroma, foreign body reaction, organ damage, infection, mesh rejection, and fistula formation may occur after implantation of the mesh. In the literature, most cases of mesh-associated enterocutaneous fistula due to migration involved polypropylene meshes. Conclusion. This case serves as a reminder of migration of composite dual meshes.

  8. 1 CFR 21.19 - Composition of part headings.

    Science.gov (United States)

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false Composition of part headings. 21.19 Section 21.19 General Provisions ADMINISTRATIVE COMMITTEE OF THE FEDERAL REGISTER PREPARATION, TRANSMITTAL, AND PROCESSING OF DOCUMENTS PREPARATION OF DOCUMENTS SUBJECT TO CODIFICATION General Headings § 21.19 Composition...

  9. Learning people's names following severe closed-head injury

    NARCIS (Netherlands)

    Milders, M.V.

    Although problems remembering people's names rank highly among the subjective complaints of patients with closed-head injuries, very few studies have examined their memory for people's names by objective measurements. An experiment is reported in which patients with severe closed-head injuries and

  10. Parental determinants of offspring head circumference using a ...

    African Journals Online (AJOL)

    The baby's head circumference was measured immediately after birth. The data were subjected to multivariate analysis. Results: The parental variables that were most predictive of babies' head circumference were mid-parental weight, maternal height, maternal weight gain during pregnancy and maternal age. Conclusion: ...

  11. Right ventricular segmentation in cardiac MRI with moving mesh correspondences.

    Science.gov (United States)

    Punithakumar, Kumaradevan; Noga, Michelle; Ben Ayed, Ismail; Boulanger, Pierre

    2015-07-01

    This study investigates automatic propagation of the right ventricle (RV) endocardial and epicardial boundaries in 4D (3D+time) magnetic resonance imaging (MRI) sequences. Based on a moving mesh (or grid generation) framework, the proposed algorithm detects the endocardium and epicardium within each cardiac phase via point-to-point correspondences. The proposed method has the following advantages over prior RV segmentation works: (1) it removes the need for a time-consuming, manually built training set; (2) it does not make prior assumptions as to the intensity distributions or shape; (3) it provides a sequence of corresponding points over time, a comprehensive input that can be very useful in cardiac applications other than segmentation, e.g., regional wall motion analysis; and (4) it is more flexible for congenital heart disease where the RV undergoes high variations in shape. Furthermore, the proposed method allows comprehensive RV volumetric analysis over the complete cardiac cycle as well as automatic detections of end-systolic and end-diastolic phases because it provides a segmentation for each time step. Evaluated quantitatively over the 48-subject data set of the MICCAI 2012 RV segmentation challenge, the proposed method yielded an average Dice score of 0.84±0.11 for the epicardium and 0.79±0.17 for the endocardium. Further, quantitative evaluations of the proposed approach in comparisons to manual contours over 23 infant hypoplastic left heart syndrome patients yielded a Dice score of 0.82±0.14, which demonstrates the robustness of the algorithm. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Approaches to the automatic generation and control of finite element meshes

    Science.gov (United States)

    Shephard, Mark S.

    1987-01-01

    The algorithmic approaches being taken to the development of finite element mesh generators capable of automatically discretizing general domains without the need for user intervention are discussed. It is demonstrated that because of the modeling demands placed on a automatic mesh generator, all the approaches taken to date produce unstructured meshes. Consideration is also given to both a priori and a posteriori mesh control devices for automatic mesh generators as well as their integration with geometric modeling and adaptive analysis procedures.

  13. High-Fidelity Geometric Modeling and Mesh Generation for Mechanics Characterization of Polycrystalline Materials

    Science.gov (United States)

    2015-01-07

    and anisotropic quadrilateral meshes, which can be used as the control mesh for high-order T- spline surface modeling. Archival publications (published...Geometric Modeling and Mesh Generation. Springer Publisher. Editor: Yongjie (Jessica) Zhang, 2013. (Review Article ) 4. J. Leng, G. Xu, Y. Zhang, J. Qian...anisotropic T-meshes for the further T- spline surface construction. Finally, a gradient flow-based method is developed to improve the T-mesh quality

  14. Baseline head in Olkiluoto

    Energy Technology Data Exchange (ETDEWEB)

    Ahokas, H.; Tammisto, E.; Lehtimaeki, T. (Poeyry Environment Oy, Vantaa (Finland))

    2008-11-15

    As part of the programme for the final disposal of the spent nuclear fuel, Posiva Oy investigates the prevailing hydrological conditions on Olkiluoto island. The hydrological investigations have included several kinds of hydrological tests such as measurements of hydraulic conductivity by flow logging and a double-packer tool as well as interference tests by pumping, in order to study the hydraulic connections between the drillholes. In addition, long-term monitoring of groundwater level and groundwater head as well as measurements of flow conditions in open drillholes, groundwater salinity (in situ EC), precipitation (including snow), sea-water level, surface flow (runoff) etc. have been part of the investigation programme aiming at the characterization of the bedrock. The data have been used in the compilation of deterministic hydro-zones and hydraulic properties for numerical flow modelling to study the flow pattern on Olkiluoto island. In addition, the compiled bedrock models have been used in the planning of the repository layout and in the analyses of the transport of radionuclides and the functionality of engineered barriers. This report focuses on the measurements of groundwater head by means of multi-packers and in connection with flow loggings. The determination of the undisturbed groundwater head (baseline head) in terms of the in situ fresh water head is the main goal of this report. The density of groundwater is strongly dependent on salinity and due to the saline groundwater deep in the bedrock in Olkiluoto the term fresh water head is used instead of hydraulic head. Taking the density of groundwater into account, the gradient of the residual pressure, which actually causes groundwater flow can be calculated. The measured and calculated heads are converted into corresponding in situ fresh water heads, which correspond to the water level (metres above sea level) in the hose that runs from the packed-off section to the ground surface. This means that

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... top of page What are some common uses of the procedure? MR imaging of the head is ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... of page What are some common uses of the procedure? MR imaging of the head is performed ...

  17. Ulnar head replacement.

    Science.gov (United States)

    Herbert, Timothy J; van Schoonhoven, Joerg

    2007-03-01

    Recent years have seen an increasing awareness of the anatomical and biomechanical significance of the distal radioulnar joint (DRUJ). With this has come a more critical approach to surgical management of DRUJ disorders and a realization that all forms of "excision arthroplasty" can only restore forearm rotation at the expense of forearm stability. This, in turn, has led to renewed interest in prosthetic replacement of the ulnar head, a procedure that had previously fallen into disrepute because of material failures with early implants, in particular, the Swanson silicone ulnar head replacement. In response to these early failures, a new prosthesis was developed in the early 1990s, using materials designed to withstand the loads across the DRUJ associated with normal functional use of the upper limb. Released onto the market in 1995 (Herbert ulnar head prosthesis), clinical experience during the last 10 years has shown that this prosthesis is able to restore forearm function after ulnar head excision and that the materials (ceramic head and noncemented titanium stem), even with normal use of the limb, are showing no signs of failure in the medium to long term. As experience with the use of an ulnar head prosthesis grows, so does its acceptance as a viable and attractive alternative to more traditional operations, such as the Darrach and Sauve-Kapandji procedures. This article discusses the current indications and contraindications for ulnar head replacement and details the surgical procedure, rehabilitation, and likely outcomes.

  18. Altering surface characteristics of polypropylene mesh via sodium hydroxide treatment.

    Science.gov (United States)

    Regis, Shawn; Jassal, Manisha; Mukherjee, Nilay; Bayon, Yves; Scarborough, Nelson; Bhowmick, Sankha

    2012-05-01

    Incisional hernias represent a serious and common complication following laparotomy. The use of synthetic (e.g. polypropylene) meshes to aid repair of these hernias has considerably reduced recurrence rates. While polypropylene is biocompatible and has a long successful clinical history in treating hernias and preventing reherniation, this material may suffer some limitations, particularly in challenging patients at risk of wound failure due to, for example, an exaggerated inflammation reaction, delayed wound healing, and infection. Surface modification of the polypropylene mesh without sacrificing its mechanical properties, critical for hernia repair, represents one way to begin to address these clinical complications. Our hypothesis is treatment of a proprietary polypropylene mesh with sodium hydroxide (NaOH) will increase in vitro NIH/3T3 cell attachment, predictive of earlier and improved cell colonization and tissue integration of polypropylene materials. Our goal is to achieve this altered surface functionality via enhanced removal of chemicals/oils used during material synthesis without compromising the mechanical properties of the mesh. We found that NaOH treatment does not appear to compromise the mechanical strength of the material, despite roughly a 10% decrease in fiber diameter. The treatment increases in vitro NIH/3T3 cell attachment within the first 72 h and this effect is sustained up to 7 days in vitro. This research demonstrates that sodium hydroxide treatment is an efficient way to modify the surface of polypropylene hernia meshes without losing the mechanical integrity of the material. This simple procedure could also allow the attachment of a variety of biomolecules to the polypropylene mesh that may aid in reducing the complications associated with polypropylene meshes today. Copyright © 2012 Wiley Periodicals, Inc.

  19. The use of Vicryl mesh in a porcine model to assess its safety as an adjunct to posterior fascial closure during retromuscular mesh placement.

    Science.gov (United States)

    Liu, L; Petro, C; Majumder, A; Fayezizadeh, M; Anderson, J; Novitsky, Y W

    2016-04-01

    Posterior component separation has become a common approach to complex abdominal wall reconstructions. This technique includes creation of an extraperitoneal retromuscular space for subsequent large synthetic mesh reinforcement. In certain cases, when complete restoration of "posterior" layer is precluded by significant tissue loss/damage, one proposed strategy is to replace the posterior fascia with an absorbable synthetic polyglactin (Vicryl) mesh. However, the safety of this strategy to prevent mesh-related visceral complication is unknown. Herein, we aimed to characterize mesh-viscera adhesion profiles and host tissue response of synthetic mesh either exposed directly to the viscera, or protected with Vicryl mesh. Using adult Yorkshire pigs, 5 × 5 cm pieces of mesh were secured to the intact peritoneum in each of the four quadrants (n = 6 pigs, 24 mesh samples). The study groups were Vicryl (V), Marlex (M), Softmesh (S), Marlex + Vicryl construct (MV), Softmesh + Vicryl construct (SV). The self-made composite meshes were then implanted with the Vicryl side facing the exposed viscera. The pigs were survived for 60 days. At necropsy, grossly, the extent and tenacity of visceral adhesions were evaluated using established scales. Histologically, all specimens for fibrous encapsulation on the visceral surface of the mesh were reviewed by an experienced pathologist blind to meshes used. At necropsy, all Vicryl meshes were completely resorbed. The mean adhesion and tenacity scores for M and MV were 1.8 and 1.1 (P > 0.05), 2.0 and 1.5 (P > 0.05), respectively; while the mean adhesion extent scores and tenacity scores for S and SV were 2.0 and 1.2 (P > 0.05), 2.0 and 1.7 (P > 0.05). No significant difference in adhesion extent and tenacity was observed between Synthetic and Vicryl composite mesh groups. Histologically, Marlex + Vicryl mesh and Softmesh + Vicryl mesh constructs had thicker fibrous capsules than the corresponding unprotected Marlex

  20. Aluminum Wire Meshes Coated with Co-Mn-Al and Co Oxides as Catalysts for Deep Ethanol Oxidation.

    Czech Academy of Sciences Publication Activity Database

    Jirátová, Květa; Kovanda, F.; Balabánová, Jana; Kšírová, P.

    2018-01-01

    Roč. 304 (2018), s. 165-171 ISSN 0920-5861. [Czech-Italian-Spanish Symposium in Catalysis /7./. Třešť, 13.06.2017-17.06.2017] R&D Projects: GA ČR GA17-08389S Institutional support: RVO:67985858 Keywords : GA17-08389S * Co-Mn-Al mixed oxides * aluminum mesh Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 4.636, year: 2016

  1. Proposed technique for inguinal hernia repair with self-gripping mesh: avoiding fixation to undesired structures.

    Science.gov (United States)

    Porrero, J L; Cano-Valderrama, O; Castillo, M J; Alonso, M T

    2015-10-01

    Self-gripping meshes have been developed to avoid fixing sutures during inguinal hernia repair. Operative time is shorter when using a self-gripping mesh than with conventional Lichtenstein repair. However, these meshes can be difficult to handle because they fix to undesired structures. The aim of this report is to describe a new technique to avoid this problem. Inguinal hernia dissection is made as usual. Once dissection is finished, a Parietex ProGrip(®) (Covidien, Dublin, Ireland) flat sheet mesh is cut depending on the size needed. A small split is made between the lower and medium third of the mesh to mark where the split for the spermatic cord will be. Using this mark, the upper third of the mesh is folded over the medium third, hiding the microgrips that make this a self-gripping mesh. In this way, only the lower third of the mesh has the microgrips exposed and the mesh can be fixed to the pubic bone and inguinal ligament without fixation to undesired structures. Once the lower third of the mesh is fixed, the split for the spermatic cord is completed and the upper part of the mesh is passed below the spermatic cord. Then, the mesh is unfolded to expose the microgrips again and the medium and upper third of the mesh are descended to its final position. This proposed technique for inguinal hernia repair with self-gripping mesh makes the surgery easier, avoiding mesh fixation to undesired structures.

  2. Subject-verb number (disagreement

    Directory of Open Access Journals (Sweden)

    Daniela Isac

    2010-01-01

    Full Text Available This paper discusses cases of number mismatches between subjects and verbs. The main proposal is that subject-verb agreement is not in number but in a different feature, that we call Cardinality. Cardinality is a feature of DPs that is computed on the basis of number features and collectivity features carried by various heads in the DP. The “computation” of the Cardinality feature proceeds internal to the feature matrix of one lexical item - the D. The values of the number and collectivity features carried by various heads in the DP are transferred to the D by means of a feature checking mechanism and the value of the Cardinality feature is then derived from these.

  3. The Subject Headings of the Morris Swett Library, USAFAS. Revised.

    Science.gov (United States)

    1980-05-15

    Sparrow) S7 (Sparrow I) S71 (Sparrow II) S72 (Sparrow III) S73 ( Sprint ) S78 (Talos-W) T2 (Terrier) T3 (Terrier iB) T31 (TOW) (Typhoon) T9 (XSSM-A-1... VOLLEYBALL (GV 1017) VOLTAGE DIVIDERS VOLTOHMETER (TK 7879.2) VOLTURNO, BATTLE OF THE, 1943 (D 763.161 V7) VOLUNTEERS, MILITARY (UB 323) VOODOOISM

  4. Effects of Mesh Size on Sieved Samples of Corophium volutator

    Science.gov (United States)

    Crewe, Tara L.; Hamilton, Diana J.; Diamond, Antony W.

    2001-08-01

    Corophium volutator (Pallas), gammaridean amphipods found on intertidal mudflats, are frequently collected in mud samples sieved on mesh screens. However, mesh sizes used vary greatly among studies, raising the possibility that sampling methods bias results. The effect of using different mesh sizes on the resulting size-frequency distributions of Corophium was tested by collecting Corophium from mud samples with 0·5 and 0·25 mm sieves. More than 90% of Corophium less than 2 mm long passed through the larger sieve. A significantly smaller, but still substantial, proportion of 2-2·9 mm Corophium (30%) was also lost. Larger size classes were unaffected by mesh size. Mesh size significantly changed the observed size-frequency distribution of Corophium, and effects varied with sampling date. It is concluded that a 0·5 mm sieve is suitable for studies concentrating on adults, but to accurately estimate Corophium density and size-frequency distributions, a 0·25 mm sieve must be used.

  5. Parallel Block Structured Adaptive Mesh Refinement on Graphics Processing Units

    Energy Technology Data Exchange (ETDEWEB)

    Beckingsale, D. A. [Atomic Weapons Establishment (AWE), Aldermaston (United Kingdom); Gaudin, W. P. [Atomic Weapons Establishment (AWE), Aldermaston (United Kingdom); Hornung, R. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gunney, B. T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gamblin, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Herdman, J. A. [Atomic Weapons Establishment (AWE), Aldermaston (United Kingdom); Jarvis, S. A. [Atomic Weapons Establishment (AWE), Aldermaston (United Kingdom)

    2014-11-17

    Block-structured adaptive mesh refinement is a technique that can be used when solving partial differential equations to reduce the number of zones necessary to achieve the required accuracy in areas of interest. These areas (shock fronts, material interfaces, etc.) are recursively covered with finer mesh patches that are grouped into a hierarchy of refinement levels. Despite the potential for large savings in computational requirements and memory usage without a corresponding reduction in accuracy, AMR adds overhead in managing the mesh hierarchy, adding complex communication and data movement requirements to a simulation. In this paper, we describe the design and implementation of a native GPU-based AMR library, including: the classes used to manage data on a mesh patch, the routines used for transferring data between GPUs on different nodes, and the data-parallel operators developed to coarsen and refine mesh data. We validate the performance and accuracy of our implementation using three test problems and two architectures: an eight-node cluster, and over four thousand nodes of Oak Ridge National Laboratory’s Titan supercomputer. Our GPU-based AMR hydrodynamics code performs up to 4.87× faster than the CPU-based implementation, and has been scaled to over four thousand GPUs using a combination of MPI and CUDA.

  6. Influence of reinforcement mesh configuration for improvement of concrete durability

    Science.gov (United States)

    Pan, Chong-gen; Jin, Wei-liang; Mao, Jiang-hong; Zhang, Hua; Sun, Li-hao; Wei, Dong

    2017-08-01

    Steel bar in concrete structures under harsh environmental conditions, such as chlorine corrosion, seriously affects its service life. Bidirectional electromigration rehabilitation (BIEM) is a new method of repair technology for reinforced concrete structures in such chloride corrosion environments. By applying the BIEM, chloride ions can be removed from the concrete and the migrating corrosion inhibit can be moved to the steel surface. In conventional engineering, the concrete structure is often configured with a multi-layer steel mesh. However, the effect of the BIEM in such structures has not yet been investigated. In this paper, the relevant simulation test is carried out to study the migration law of chloride ions and the migrating corrosion inhibitor in a concrete specimen with complex steel mesh under different energizing modes. The results show that the efficiency of the BIEM increases 50% in both the monolayer steel mesh and the double-layer steel mesh. By using the single-sided BIEM, 87% of the chloride ions are removed from the steel surface. The different step modes can affect the chloride ion removal. The chloride ions within the range of the reinforcement protective cover are easier to be removed than those in the concrete between the two layers of steel mesh. However, the amount of migrating corrosion inhibitor is larger in the latter circumstances.

  7. Mesh Resolution Effect on 3D RANS Turbomachinery Flow Simulations

    CERN Document Server

    Yershov, Sergiy

    2016-01-01

    The paper presents the study of the effect of a mesh refinement on numerical results of 3D RANS computations of turbomachinery flows. The CFD solver F, which based on the second-order accurate ENO scheme, is used in this study. The simplified multigrid algorithm and local time stepping permit decreasing computational time. The flow computations are performed for a number of turbine and compressor cascades and stages. In all flow cases, the successively refined meshes of H-type with an approximate orthogonalization near the solid walls were generated. The results obtained are compared in order to estimate their both mesh convergence and ability to resolve the transonic flow pattern. It is concluded that for thorough studying the fine phenomena of the 3D turbomachinery flows, it makes sense to use the computational meshes with the number of cells from several millions up to several hundred millions per a single turbomachinery blade channel, while for industrial computations, a mesh of about or less than one mil...

  8. Scar endometriosis developing after an umbilical hernia repair with mesh.

    Science.gov (United States)

    Majeski, James; Craggie, James

    2004-05-01

    A 44-year-old female was initially evaluated for a 3-cm umbilical hernia, which developed after a laparoscopic myomectomy performed seven years prior. The umbilical hernia was repaired using a synthetic mesh. Eight months after the umbilical hernia repair, the patient returned with chronic pain in a 3-cm raised mass originating from the umbilical hernia repair incision. The mass and mesh were surgically removed. The umbilical fascial defect was repaired with a primary fascia-to-fascia closure and the umbilicus was reconstructed from adjacent skin. The mass was found histologically to be endometriosis and fascial scarring with a foreign body reaction to synthetic mesh. Umbilical endometriosis developed either from peritoneal endometrial seeding from a laparoscopic myomectomy or from metaplasia of multipotential cells, which developed into endometriosis due to inflammatory stimulation by the synthetic mesh. Synthetic mesh probably should be avoided in the surgical repair of a laparoscopically caused umbilical hernia in a premenopausal female especially if there is a history of pelvic endometriosis.

  9. Mesh Network Architecture for Enabling Inter-Spacecraft Communication

    Science.gov (United States)

    Becker, Christopher; Merrill, Garrick

    2017-01-01

    To enable communication between spacecraft operating in a formation or small constellation, a mesh network architecture was developed and tested using a time division multiple access (TDMA) communication scheme. The network is designed to allow for the exchange of telemetry and other data between spacecraft to enable collaboration between small spacecraft. The system uses a peer-to-peer topology with no central router, so that it does not have a single point of failure. The mesh network is dynamically configurable to allow for addition and subtraction of new spacecraft into the communication network. Flight testing was performed using an unmanned aerial system (UAS) formation acting as a spacecraft analogue and providing a stressing environment to prove mesh network performance. The mesh network was primarily devised to provide low latency, high frequency communication but is flexible and can also be configured to provide higher bandwidth for applications desiring high data throughput. The network includes a relay functionality that extends the maximum range between spacecraft in the network by relaying data from node to node. The mesh network control is implemented completely in software making it hardware agnostic, thereby allowing it to function with a wide variety of existing radios and computing platforms..

  10. Standard polypropylene mesh vs lightweight mesh for Lichtenstein repair of primary inguinal hernia: a randomized controlled trial.

    Science.gov (United States)

    Demetrashvili, Zaza; Khutsishvili, Kakhi; Pipia, Irakli; Kenchadze, Giorgi; Ekaladze, Eka

    2014-12-01

    The aim of the present clinical study was to compare early and late outcomes after inguinal hernia repair with the heavyweight mesh (HW) and lightweight mesh (LW) during a 3 year follow-up period. 226 patients were randomized into LW and HW mesh groups, both of which underwent unilateral primary inguinal hernia repair via the Lichtenstein technique. Wound complications (infection, hematoma, seroma), hernia recurrence, pain and feeling of foreign body in inguinal area were determined in patients. Pain was measured by visual analogue scale. No statistical difference has been found between LW and HW groups by wound complication (P = 0.80). One case of hernia recurrence has been mentioned in both groups one year after hernioplasty. But there was no detectable difference between the two groups. No significant difference has been found between LW and HW groups by frequency of chronic pain 7 days, 1 and 3 months, 1, 2, and 3 years after surgery. As for the feeling of foreign body in groin it is similar in both groups after 1 and 3 months. Level of feeling of foreign body was significantly lower in LW group 1, 2, and 3 years after surgery, than in HW group (P = 0.03, P = 0.02, P = 0.02, respectively). Our research shows no significant difference in wound complications, hernia recurrence and chronic pain after Lichtenstein hernioplasty, by using of LW and HW meshes. The usage of the LW mesh was associated with less feeling of foreign body than that of the HW mesh, what can be considered as prevalence of LW mesh hernioplasty. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear ... or other physician. To locate a medical imaging or radiation oncology provider in your community, you can search the ...

  13. Overview of Head Injuries

    Science.gov (United States)

    ... brain. If the head injury is very severe, mechanical ventilation may be used. Doctors control blood pressure and minimize the amount of brain swelling by adjusting the amount of intravenous fluids given and sometimes by giving intravenous drugs that ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... headaches, dizziness, and other symptoms of aneurysm, bleeding, stroke and brain tumors. It also helps your doctor ... scanning provides more detailed information on head injuries, stroke , brain tumors and other brain diseases than regular ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... limitations of CT Scanning of the Head? A person who is very large may not fit into ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... medically necessary because of potential risk to the baby. This risk is, however, minimal with head CT ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... assess head injuries, severe headaches, dizziness, and other symptoms of aneurysm, bleeding, stroke and brain tumors. It ... within the brain shortly after a patient exhibits symptoms of a stroke. a stroke, especially with a ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scans in children should always be done with low-dose technique. top of page What are the ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for Head and ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... this tunnel. Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite ... medically necessary because of potential risk to the baby. This risk is, however, minimal with head CT ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... head CT scanning. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special x-ray equipment to help assess head injuries, severe headaches, dizziness, and other symptoms of aneurysm, ... cancer. In emergency cases, it can reveal internal injuries and bleeding quickly enough to help save lives. ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... traditional x-rays, particularly of soft tissues and blood vessels. CT scanning provides more detailed information on head injuries, stroke , brain tumors and other brain diseases than regular radiographs (x-rays). top of page ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... used to detect: bleeding, brain injury and skull fractures in patients with head injuries. bleeding caused by ... a few seconds, and even faster in small children. Such speed is beneficial for all patients but ...

  4. TCGA head Neck

    Science.gov (United States)

    Investigators with The Cancer Genome Atlas (TCGA) Research Network have discovered genomic differences – with potentially important clinical implications – in head and neck cancers caused by infection with the human papillomavirus (HPV).

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... for Head and Neck Cancer Others American Stroke Association National Stroke Association top of page This page ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images of internal organs, bones, soft tissue and blood vessels provide greater detail than traditional x-rays, particularly of soft tissues and blood vessels. CT scanning provides more detailed information on head ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... sometimes compared to looking into a loaf of bread by cutting the loaf into thin slices. When ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ...

  8. Early Head Start Evaluation

    Data.gov (United States)

    U.S. Department of Health & Human Services — Longitudinal information from an evaluation where children were randomly assigned to Early Head Start or community services as usual;direct assessments and...

  9. Head Start Impact Study

    Data.gov (United States)

    U.S. Department of Health & Human Services — Nationally representative, longitudinal information from an evaluation where children were randomly assigned to Head Start or community services as usual;direct...

  10. Head CT scan

    Science.gov (United States)

    ... be: Stored Viewed on a monitor Printed on film Three-dimensional models of the head area can ... when you have certain other signs or symptoms Hearing loss (in some people) Symptoms of damage to ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... and other symptoms of aneurysm, bleeding, stroke and brain tumors. It also helps your doctor to evaluate your ... provides more detailed information on head injuries, stroke , brain tumors and other brain diseases than regular radiographs (x- ...

  12. Head and Neck Cancer

    Science.gov (United States)

    ... increase the risk of head and neck cancer. Environmental or occupational inhalants. Inhaling asbestos, wood dust, paint ... from the American Society of Clinical Oncology. Review dictionary articles to help understand medical phrases and terms ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... used to detect: bleeding, brain injury and skull fractures in patients with head injuries. bleeding caused by ... are present in the paranasal sinuses. plan radiation therapy for cancer of the brain or other tissues. ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... used to detect: bleeding, brain injury and skull fractures in patients with head injuries. bleeding caused by ... is also performed to: evaluate the extent of bone and soft tissue damage in patients with facial ...

  15. Large pore size and controlled mesh elongation are relevant predictors for mesh integration quality and low shrinkage--Systematic analysis of key parameters of meshes in a novel minipig hernia model.

    Science.gov (United States)

    Weyhe, Dirk; Cobb, William; Lecuivre, Julie; Alves, Antoine; Ladet, Sebastien; Lomanto, Davide; Bayon, Yves

    2015-10-01

    Prosthetic mesh implants in hernia repair are frequently used based on the fact that lower recurrence rates are detected. However, an undesirable side effect is persistent foreign body reaction that drives adhesions and shrinkage among other things in the course of time. Thereby a variety of meshes have been created in an attempt to alleviate these side effects, and particular relating to shrinkage, the ideal mesh has not been developed. Large pore size is one of the properties to get better ingrowth of the implants but could also be a risk factor to shrinkage behavior. The aim of this preclinical study was to determine optimal pore size based on mesh integration and shrinkage in a hernia minipig model. Twenty female minipigs were each implanted at four abdominal retromuscular sites with meshes (designed and knitted specifically for this study) that had various weights and pore sizes, but similar weave. At 3 and 21 weeks post-operation, ten pigs each were euthanized. Mesh integration and shrinkage were evaluated through macroscopic observation, biomechanical testing and histopathological analysis. The large pore meshes (6.1-6.6 mm(2)) showed significantly better integration than small pore (0.9-1.1 mm(2)) counterparts, by biomechanical testing and histological assessment. This was independent of mesh weight. The lightweight small pore mesh exhibited significantly more shrinkage than any of the other meshes, while the three-dimensional heavyweight large pore mesh exhibited the least shrinkage. Mesh shrinkage and elongation at 50 Newton (N) as one parameter of the implant structural stability appeared to be strongly interrelated. Tissue ingrowth of meshes depends on increasing pore size. Macroporous mesh design >1.5 mm diameter appears to be optimal in terms of mesh integration. Lightweight meshes with a large pore size on one hand and a lack of structural stability on the other hand drives mesh shrinkage. High stretchability (Elongation >50 N) induces higher

  16. Subject cataloguing of the works of fiction at the National and University Library

    Directory of Open Access Journals (Sweden)

    Tatjana Kovač

    2006-01-01

    Full Text Available The article reviews the principles of construction and policies of application of subject headings to works of fiction at the National and University Library in Ljubljana, Slovenia. The records are created in COMARC format, and the literary type, genre and the language of a document are each assigned a code, whereas literature is also indexed by using UDC class numbers. The principles for constructing and assigning subject headings for fiction are in accordance with the IFLA Principles Underlying Subject Heading Languages, and the rules of the Slovenian General List of Subject Headings (2002. The author presents the general and more specific rules and procedures for the construction of subject headings. Most frequently used subject headings for the works of fiction are name, topical or geographic headings.

  17. Detection of altered hippocampal morphology in multiple sclerosis-associated depression using automated surface mesh modeling

    Science.gov (United States)

    Gold, Stefan M.; O’Connor, Mary-Frances; Gill, Raja; Kern, Kyle C.; Shi, Yonggang; Henry, Roland G.; Pelletier, Daniel; Mohr, David C.; Sicotte, Nancy L.

    2013-01-01

    Depression is very common in multiple sclerosis (MS) but the underlying biological mechanisms are poorly understood. The hippocampus plays a key role in mood regulation and is implicated in the pathogenesis of depression. This study utilizes volumetric and shape analyses of the hippocampus to characterize neuroanatomical correlates of depression in MS. A cross-section of 109 female MS patients was evaluated. Bilateral hippocampi were segmented from MRI scans (volumetric T1-weighted, 1mm3) using automated tools. Shape analysis was performed using surface mesh modeling. Depression was assessed using the Center for Epidemiologic Studies-Depression (CES-D) scale. Eighty-three subjects were classified as low depression (CES-D 0-20) versus 26 subjects with high depression (CES-D ≥ 21). Right hippocampal volumes (p=0.04) were smaller in the high depression versus the low depression groups, but there was no significant difference in left hippocampal volumes. Surface rendering analysis revealed hippocampal shape changes in depressed MS patients were clustered in the right hippocampus. Significant associations were found between right hippocampal shape and affective symptoms but not vegetative symptoms of depression. Our results suggested that regionally clustered reductions in hippocampal thickness can be detected by automated surface mesh modeling and may be a biological substrate of MS depression in female patients. PMID:22847919

  18. Effects of Soccer Heading on Brain Structure and Function

    Science.gov (United States)

    Rodrigues, Ana Carolina; Lasmar, Rodrigo Pace; Caramelli, Paulo

    2016-01-01

    Soccer is the most popular sport in the world, with more than 265 million players worldwide, including professional and amateur ones. Soccer is unique in comparison to other sports, as it is the only sport in which participants purposely use their head to hit the ball. Heading is considered as an offensive or defensive move whereby the player’s unprotected head is used to deliberately impact the ball and direct it during play. A soccer player can be subjected to an average of 6–12 incidents of heading the ball per competitive game, where the ball reaches high velocities. Moreover, in practice sessions, heading training, which involves heading the ball repeatedly at low velocities, is common. Although the scientific community, as well as the media, has focused on the effects of concussions in contact sports, the role of subconcussive impacts, as it can occur during heading, has recently gained attention, considering that it may represent an additional mechanism of cumulative brain injury. The purpose of this study is to review the existing literature regarding the effects of soccer heading on brain structure and function. Only in the last years, some investigations have addressed the impact of heading on brain structure, by using neuroimaging techniques. Similarly, there have been some recent studies investigating biochemical markers of brain injury in soccer players. There is evidence of association between heading and abnormal brain structure, but the data are still preliminary. Also, some studies have suggested that subconcussive head impacts, as heading, could cause cognitive impairment, whereas others have not corroborated this finding. Questions persist as to whether or not heading is deleterious to cognitive functioning. Further studies, especially with longitudinal designs, are needed to clarify the clinical significance of heading as a cause of brain injury and to identify risk factors. Such investigations might contribute to the establishment of safety

  19. Effects of soccer heading on brain structure and function

    Directory of Open Access Journals (Sweden)

    Ana Carolina Oliveira Rodrigues

    2016-03-01

    Full Text Available Soccer is the most popular sport in the world, with more than 265 million players worldwide, including professional and amateur ones. Soccer is unique in comparison to other sports, as it is the only sport in which participants purposely use their head to hit the ball. Heading is considered an offensive or defensive move whereby the player’s unprotected head is used to deliberately impact the ball and direct it during play. A soccer player can be subjected to an average of six to twelve incidents of heading the ball per competitive game, where the ball reaches high velocities. Moreover, in practice sessions, heading training, which involves heading the ball repeatedly at low velocities, is common. Although the scientific community, as well as the media, has focused on the effects of concussions in contact sports, the role of subconcussive impacts, as it can occur during heading, has recently gained attention, considering that it may represent an additional mechanism of cumulative brain injury. The purpose of this study is to review the existing literature regarding the effects of soccer heading on brain structure and function. Only in the last years some investigations have addressed the impact of heading on brain structure, by using neuroimaging techniques. Similarly, there have been some recent studies investigating biochemical markers of brain injury in soccer players. There is evidence of association between heading and abnormal brain structure, but the data are still preliminary. Also, some studies have suggested that subconcussive head impacts, as heading, could cause cognitive impairment, whereas others have not corroborated this finding. Questions persist as to whether or not heading is deleterious to cognitive functioning. Further studies, especially with longitudinal designs, are needed to clarify the clinical significance of heading as a cause of brain injury and to identify risk factors. Such investigations might contribute to the

  20. Dynamic Resource Management in 802.11 Wireless Mesh Networks

    Directory of Open Access Journals (Sweden)

    George Athanasiou

    2012-01-01

    Full Text Available The association/handoff procedures are important components in a balanced operation of 802.11-based wireless mesh networks. In this paper, we introduce the concept of cooperative association where the stations (STA can share useful information in order to improve the performance of the association/reassociation procedures. Furthermore, in this work we introduce a load balancing mechanism that can be applied in mesh networks. This mechanism operates in a cross-layer manner taking into account uplink and downlink channel information, routing information, and congestion-based information. Our load balancing mechanism is based on a fairness index that is measured at each access point (AP neighborhood. This index reflects the way the communication load is shared in the neighboring APs. The iterative heuristic algorithms that we propose controls the communication load of each mesh AP in a distributed manner. We evaluate the performance of our mechanisms through OPNET simulations.