  1. 3D Subharmonic Ultrasound Imaging In Vitro and In Vivo

    Science.gov (United States)

    Eisenbrey, John R.; Sridharan, Anush; Machado, Priscilla; Zhao, Hongjia; Halldorsdottir, Valgerdur G.; Dave, Jaydev K.; Liu, Ji-Bin; Park, Suhyun; Dianis, Scott; Wallace, Kirk; Thomenius, Kai E.; Forsberg, F.

    2012-01-01

    Rationale and Objectives While contrast-enhanced ultrasound imaging techniques such as harmonic imaging (HI) have evolved to reduce tissue signals using the nonlinear properties of the contrast agent, levels of background suppression have been mixed. Subharmonic imaging (SHI) offers near-complete tissue suppression by centering the receive bandwidth at half the transmitting frequency. In this work we demonstrate the feasibility of 3D SHI and compare it to 3D HI. Materials and Methods 3D HI and SHI were implemented on a Logiq 9 ultrasound scanner (GE Healthcare, Milwaukee, Wisconsin) with a 4D10L probe. Four-cycle SHI was implemented to transmit at 5.8 MHz and receive at 2.9 MHz, while 2-cycle HI was implemented to transmit at 5 MHz and receive at 10 MHz. The ultrasound contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) was imaged within a flow phantom and the lower pole of two canine kidneys in both HI and SHI modes. Contrast to tissue ratios (CTR) and rendered images were compared offline. Results SHI resulted in significant improvement in CTR levels relative to HI both in vitro (12.11±0.52 vs. 2.67±0.77, p<0.001) and in vivo (5.74±1.92 vs. 2.40±0.48, p=0.04). Rendered 3D SHI images provided better tissue suppression and a greater overall view of vessels in a flow phantom and canine renal vasculature. Conclusions The successful implementation of SHI in 3D allows imaging of vascular networks over a heterogeneous sample volume and should improve future diagnostic accuracy. Additionally, 3D SHI provides improved CTR values relative to 3D HI. PMID:22464198

  2. Parametric subharmonic imaging using a commercial intravascular ultrasound scanner: an in vivo feasibility study.

    Science.gov (United States)

    Eisenbrey, John R; Sridharan, Anush; deMuinck, Ebo D; Doyley, Marvin M; Forsberg, Flemming

    2012-03-01

    The feasibility of visualizing atherosclerotic plaque using parametric subharmonic intravascular ultrasound (IVUS) was investigated in vivo. Atherosclerosis was induced in the aorta of 2 rabbits. Following injection of Definity (Lantheus Medical Imaging, North Billerica, MA), radiofrequency IVUS signals were acquired at 40 MHz with a Galaxy IVUS scanner (Boston Scientific/Scimed, Natick, MA). Subharmonic imaging (SHI; receiving at 20 MHz) was performed offline by applying an 8-order equalization filter. Contrast-to-tissue ratios (CTRs) were computed for the vessel relative to the plaque area over 4 time points. Contrast-to-tissue ratios were also calculated for the plaque-tissue and vessel-tissue from 4 tissue regions of interest at 4 time points. Finally, parametric images showing the cumulative maximum intensity (CMI), time to peak, perfusion (PER), and time-integrated intensity (TII) were generated for the fundamental and subharmonic data sets, and CTR measurements were repeated. Injection of the contrast agent resulted in improved delineation between plaque and the vessel lumen. Subharmonic imaging resulted in noticeable tissue suppression, although the intensity from the contrast agent was reduced. No significant improvement in the plaque to vessel lumen CTR was observed between the subharmonic and fundamental IVUS (2.1 ± 3.64 versus 2.2 ± 4.20; P = .5). However, the CTR for plaque-tissue was improved (11.8 ± 7.32 versus 9.9 ± 7.06; P < .0001) for SHI relative to fundamental imaging. Cumulative-maximum-intensity and TII maps of both fundamental and subharmonic data provided increased CTRs relative to nonparametric data sets (P < .002). Additionally, the CMI, PER, and TII of SHI IVUS showed significantly improved vessel-plaque CTRs for SHI relative to the fundamental (P < .04). Parametric SHI IVUS of atherosclerotic plaque is feasible and improves the visualization of the plaque.

  3. Parametric Subharmonic Imaging Using a Commercial Intravascular Ultrasound Scanner An In Vivo Feasibility Study

    Science.gov (United States)

    Eisenbrey, John R.; Sridharan, Anush; deMuinck, Ebo D.; Doyley, Marvin M.; Forsberg, Flemming

    2013-01-01

    Objectives The feasibility of visualizing atherosclerotic plaque using parametric subharmonic intravascular ultrasound (IVUS) was investigated in vivo. Methods Atherosclerosis was induced in the aorta of 2 rabbits. Following injection of Definity (Lantheus Medical Imaging, North Billerica, MA), radiofrequency IVUS signals were acquired at 40 MHz with a Galaxy IVUS scanner (Boston Scientific/Scimed, Natick, MA). Subharmonic imaging (SHI; receiving at 20 MHz) was performed offline by applying an 8-order equalization filter. Contrast-to-tissue ratios (CTRs) were computed for the vessel relative to the plaque area over 4 time points. Contrast-to-tissue ratios were also calculated for the plaque-tissue and vessel-tissue from 4 tissue regions of interest at 4 time points. Finally, parametric images showing the cumulative maximum intensity (CMI), time to peak, perfusion (PER), and time-integrated intensity (TII) were generated for the fundamental and subharmonic data sets, and CTR measurements were repeated. Results Injection of the contrast agent resulted in improved delineation between plaque and the vessel lumen. Subharmonic imaging resulted in noticeable tissue suppression, although the intensity from the contrast agent was reduced. No significant improvement in the plaque to vessel lumen CTR was observed between the subharmonic and fundamental IVUS (2.1 ± 3.64 versus 2.2 ± 4.20; P = .5). However, the CTR for plaque-tissue was improved (11.8 ± 7.32 versus 9.9 ± 7.06; P < .0001) for SHI relative to fundamental imaging. Cumulative-maximum-intensity and TII maps of both fundamental and subharmonic data provided increased CTRs relative to nonparametric data sets (P< .002). Additionally, the CMI, PER, and TII of SHI IVUS showed significantly improved vessel-plaque CTRs for SHI relative to the fundamental (P < .04). Conclusions Parametric SHI IVUS of atherosclerotic plaque is feasible and improves the visualization of the plaque. PMID:22368126

  4. Simultaneous grayscale and subharmonic ultrasound imaging on a modified commercial scanner.

    Science.gov (United States)

    Eisenbrey, J R; Dave, J K; Halldorsdottir, V G; Merton, D A; Machado, P; Liu, J B; Miller, C; Gonzalez, J M; Park, S; Dianis, S; Chalek, C L; Thomenius, K E; Brown, D B; Navarro, V; Forsberg, F

    2011-12-01

    To demonstrate the feasibility of simultaneous dual fundamental grayscale and subharmonic imaging on a modified commercial scanner. The ability to generate signals at half the insonation frequency is exclusive to ultrasound contrast agents (UCA). Thus, subharmonic imaging (SHI; transmitting at f(0) and receiving at f(0)/2) provides improved visualization of UCA within the vasculature via suppression of the surrounding tissue echoes. While this capability has proven useful in a variety of clinical applications, the SHI suppression of surrounding tissue landmarks (which are needed for sonographic navigation) also limits it use as a primary imaging modality. In this paper we present results using a commercial ultrasound scanner modified to allow imaging in both grayscale (f(0)=4.0 MHz) and SHI (f(0)=2.5 MHz, f(0)/2=1.25 MHz) modes in real time. A Logiq 9 ultrasound scanner (GE Healthcare, Milwaukee, WI) with a 4C curvilinear probe was modified to provide this capability. Four commercially available UCA (Definity, Lantheus Medical Imaging, North Billerica, MA; Optison, GE Healthcare, Princeton, NJ; SonoVue, Bracco Imaging, Milan, Italy; and Sonazoid, GE Healthcare, Oslo, Norway) were all investigated in vitro over an acoustic output range of 3.34 MPa. In vivo the subharmonic response of Sonazoid was investigated in the portal veins of four canines (open abdominal cavity) and four patients with suspected portal hypertension. In vitro, the four UCA showed an average maximum subharmonic amplitude of 44.1±5.4 dB above the noise floor with a maximum subharmonic amplitude of 48.6±1.6 dB provided by Sonazoid. The average in vivo maximum signal above the noise floor from Sonazoid was 20.8±2.3 dB in canines and 33.9±5.2 dB in humans. Subharmonic amplitude as a function of acoustic output in both groups matched the S-curve behavior of the agent observed in vitro. The dual grayscale imaging provided easier sonographic navigation, while the degree of tissue suppression in SHI

  5. Delineation of atherosclerotic plaque using subharmonic imaging filtering techniques and a commercial intravascular ultrasound system.

    Science.gov (United States)

    Sridharan, Anush; Eisenbrey, John R; Machado, Priscilla; deMuinck, Ebo D; Doyley, Marvin M; Forsberg, Flemming

    2013-01-01

    The ability to delineate atherosclerotic plaque from the surrounding tissue using custom-developed subharmonic imaging (SHI) digital filtering techniques was investigated in vivo using a commercially available system. Atherosclerosis was induced in the aorta of two Watanabe Heritable Hyperlipidemic rabbits following which injections of an ultrasound contrast agent (UCA) Definity (Lantheus Medical Imaging, N Billerica, Massachusetts) were administered. Imaging was performed using a Galaxy intravascular ultrasound (IVUS) scanner (Boston Scientific, Natick, Massachusetts) equipped with an Atlantis® SR Pro Imaging Catheter (Boston Scientific). Four preliminary band-pass filters were designed to isolate the subharmonic signal (from surrounding tissue) and applied to the radio-frequency (RF) data. Preliminary filter performances were compared in terms of vessel-tissue contrast-to-tissue ratio (CTR) and visual examination. Based on preliminary results, a subharmonic adaptive filter and a stopband (SB) filter were designed and applied to the RF data. Images were classified as fundamental, SHI, and SB. Four readers performed qualitative analysis of 168 randomly selected images (across all three imaging modes). The images were scored for overall image quality, image noise, plaque visualization, and vessel lumen visualization. A Wilcoxon signed-rank test was used to compare the scores followed by intraclass correlation (ICC) evaluation. Quantitative analysis was performed by calculating the CTRs for the vessel-to-plaque and vessel-to-tissue (compared using a paired student's t test). Qualitative analysis showed SHI and SB to have significantly less image noise relative to the fundamental mode (p < 0.001). Fundamental mode scored significantly higher than SHI and SB for the remaining three categories. ICC showed mixed results among reader evaluation for delineation of plaque. However, quantitatively, SHI produced the best vessel-plaque CTR.

  6. Recent Experiences and Advances in Contrast-Enhanced Subharmonic Ultrasound

    Directory of Open Access Journals (Sweden)

    John R. Eisenbrey

    2015-01-01

    Full Text Available Nonlinear contrast-enhanced ultrasound imaging schemes strive to suppress tissue signals in order to better visualize nonlinear signals from blood-pooling ultrasound contrast agents. Because tissue does not generate a subharmonic response (i.e., signal at half the transmit frequency, subharmonic imaging has been proposed as a method for isolating ultrasound microbubble signals while suppressing surrounding tissue signals. In this paper, we summarize recent advances in the use of subharmonic imaging in vivo. These advances include the implementation of subharmonic imaging on linear and curvilinear arrays, intravascular probes, and three-dimensional probes for breast, renal, liver, plaque, and tumor imaging.

  7. Recent Experiences and Advances in Contrast-Enhanced Subharmonic Ultrasound.

    Science.gov (United States)

    Eisenbrey, John R; Sridharan, Anush; Liu, Ji-Bin; Forsberg, Flemming

    2015-01-01

    Nonlinear contrast-enhanced ultrasound imaging schemes strive to suppress tissue signals in order to better visualize nonlinear signals from blood-pooling ultrasound contrast agents. Because tissue does not generate a subharmonic response (i.e., signal at half the transmit frequency), subharmonic imaging has been proposed as a method for isolating ultrasound microbubble signals while suppressing surrounding tissue signals. In this paper, we summarize recent advances in the use of subharmonic imaging in vivo. These advances include the implementation of subharmonic imaging on linear and curvilinear arrays, intravascular probes, and three-dimensional probes for breast, renal, liver, plaque, and tumor imaging.

  8. Three-dimensional subharmonic ultrasound imaging in vitro and in vivo.

    Science.gov (United States)

    Eisenbrey, John R; Sridharan, Anush; Machado, Priscilla; Zhao, Hongjia; Halldorsdottir, Valgerdur G; Dave, Jaydev K; Liu, Ji-Bin; Park, Suhyun; Dianis, Scott; Wallace, Kirk; Thomenius, Kai E; Forsberg, Flemming

    2012-06-01

    Although contrast-enhanced ultrasound imaging techniques such as harmonic imaging (HI) have evolved to reduce tissue signals using the nonlinear properties of the contrast agent, levels of background suppression have been mixed. Subharmonic imaging (SHI) offers near complete tissue suppression by centering the receive bandwidth at half the transmitting frequency. The aims of this study were to demonstrate the feasibility of three-dimensional (3D) SHI and to compare it to 3D HI. Three-dimensional HI and SHI were implemented on a Logiq 9 ultrasound scanner with a 4D10L probe. Four-cycle SHI was implemented to transmit at 5.8 MHz and receive at 2.9 MHz, while two-cycle HI was implemented to transmit at 5 MHz and receive at 10 MHz. The ultrasound contrast agent Definity was imaged within a flow phantom and the lower pole of two canine kidneys in both HI and SHI modes. Contrast-to-tissue ratios and rendered images were compared offline. SHI resulted in significant improvement in contrast-to-tissue ratios relative to HI both in vitro (12.11 ± 0.52 vs 2.67 ± 0.77, P< .001) and in vivo (5.74 ± 1.92 vs 2.40 ± 0.48, P = .04). Rendered 3D subharmonic images provided better tissue suppression and a greater overall view of vessels in a flow phantom and canine renal vasculature. The successful implementation of SHI in 3D allows imaging of vascular networks over a heterogeneous sample volume and should improve future diagnostic accuracy. Additionally, 3D SHI provides improved contrast-to-tissue ratios relative to 3D HI. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  9. Perfusion estimation using contrast-enhanced 3-dimensional subharmonic ultrasound imaging: an in vivo study.

    Science.gov (United States)

    Sridharan, Anush; Eisenbrey, John R; Liu, Ji-Bin; Machado, Priscilla; Halldorsdottir, Valgerdur G; Dave, Jaydev K; Zhao, Hongjia; He, Yu; Park, Suhyun; Dianis, Scott; Wallace, Kirk; Thomenius, Kai E; Forsberg, Flemming

    2013-09-01

    The ability to estimate tissue perfusion (in milliliter per minute per gram) in vivo using contrast-enhanced 3-dimensional (3D) harmonic and subharmonic ultrasound imaging was investigated. A LOGIQ™ 9 scanner (GE Healthcare, Milwaukee, WI) equipped with a 4D10L probe was modified to perform 3D harmonic imaging (HI; f(transmit), 5 MHz and f(receive), 10 MHz) and subharmonic imaging (SHI; f(transmit), 5.8 MHz and f(receive), 2.9 MHz). In vivo imaging was performed in the lower pole of both kidneys in 5 open-abdomen canines after injection of the ultrasound contrast agent (UCA) Definity (Lantheus Medical Imaging, N Billerica, MA). The canines received a 5-μL/kg bolus injection of Definity for HI and a 20-μL/kg bolus for SHI in triplicate for each kidney. Ultrasound data acquisition was started just before the injection of UCA (to capture the wash-in) and continued until washout. A microvascular staining technique based on stable (nonradioactive) isotope-labeled microspheres (Biophysics Assay Laboratory, Inc, Worcester, MA) was used to quantify the degree of perfusion in each kidney (the reference standard). Ligating a surgically exposed branch of the renal arteries induced lower perfusion rates. This was followed by additional contrast-enhanced imaging and microsphere injections to measure post-ligation perfusion. Slice data were extracted from the 3D ultrasound volumes and used to generate time-intensity curves offline in the regions corresponding to the tissue samples used for microvascular staining. The midline plane was also selected from the 3D volume (as a quasi-2-dimensional [2D] image) and compared with the 3D imaging modes. Perfusion was estimated from the initial slope of the fractional blood volume uptake (for both HI and SHI) and compared with the reference standard using linear regression analysis. Both 3D HI and SHI were able to provide visualization of flow and, thus, perfusion in the kidneys. However, SHI provided near-complete tissue suppression

  10. Perfusion estimation using contrast enhanced three-dimensional subharmonic ultrasound imaging: an in vivo study

    Science.gov (United States)

    Sridharan, Anush; Eisenbrey, John R.; Liu, Ji-Bin; Machado, Priscilla; Halldorsdottir, Valgerdur G.; Dave, Jaydev K.; Zhao, Hongjia; He, Yu; Park, Suhyun; Dianis, Scott; Wallace, Kirk; Thomenius, Kai E.; Forsberg, Flemming

    2013-01-01

    Objectives The ability to estimate tissue perfusion (in mL/min/g) in vivo using contrast-enhanced three-dimensional (3D) harmonic and subharmonic ultrasound imaging was investigated. Materials and Methods A Logiq 9 scanner (GE Healthcare, Milwaukee, WI) equipped with a 4D10L probe was modified to perform 3D harmonic imaging (HI; ftransmit = 5 MHz and freceive = 10 MHz) and subharmonic imaging (SHI; ftransmit= 5.8 MHz and freceive= 2.9 MHz). In vivo imaging was performed in the lower pole of both kidneys in five open-abdomen canines after injection of the ultrasound contrast agent (UCA) Definity (Lantheus Medical Imaging, N Billerica, MA). The canines received a 5 μL/kg bolus injection of Definity for HI and a 20 μL/kg bolus for SHI in triplicate for each kidney. Ultrasound data acquisition was started just prior to injection of UCA (in order to capture the wash-in) and continued until washout. A microvascular staining technique based on stable (non-radioactive) isotope-labeled microspheres (Biophysics Assay Laboratory Inc, Worcester, MA) was used to quantify the degree of perfusion in each kidney (the reference standard). Ligating a surgically exposed branch of the renal arteries induced lower perfusion rates. This was followed by additional contrast-enhanced imaging and microsphere injections to measure post-ligation perfusion. Slice data were extracted from the 3D ultrasound volumes and used to generate time-intensity curves off-line in the regions corresponding to the tissue samples used for microvascular staining. The mid-line plane was also selected from the 3D volume (as a quasi-2D image) and compared to the 3D imaging modes. Perfusion was estimated from the initial slope of the fractional blood volume uptake (for both HI and SHI) and compared to the reference standard using linear regression analysis. Results Both 3D HI and SHI were able to provide visualization of flow and, thus, perfusion in the kidneys. However, SHI provided near complete tissue

  11. Parametric imaging using subharmonic signals from ultrasound contrast agents in patients with breast lesions.

    Science.gov (United States)

    Eisenbrey, John R; Dave, Jaydev K; Merton, Daniel A; Palazzo, Juan P; Hall, Anne L; Forsberg, Flemming

    2011-01-01

    Parametric maps showing perfusion of contrast media can be useful tools for characterizing lesions in breast tissue. In this study we show the feasibility of parametric subharmonic imaging (SHI), which allows imaging of a vascular marker (the ultrasound contrast agent) while providing near complete tissue suppression. Digital SHI clips of 16 breast lesions from 14 women were acquired. Patients were scanned using a modified LOGIQ 9 scanner (GE Healthcare, Waukesha, WI) transmitting/receiving at 4.4/2.2 MHz. Using motion-compensated cumulative maximum intensity (CMI) sequences, parametric maps were generated for each lesion showing the time to peak (TTP), estimated perfusion (EP), and area under the time-intensity curve (AUC). Findings were grouped and compared according to biopsy results as benign lesions (n = 12, including 5 fibroadenomas and 3 cysts) and carcinomas (n = 4). For each lesion CMI, TTP, EP, and AUC parametric images were generated. No significant variations were detected with CMI (P = .80), TTP (P = .35), or AUC (P = .65). A statistically significant variation was detected for the average pixel EP (P = .002). Especially, differences were seen between carcinoma and benign lesions (mean ± SD, 0.10 ± 0.03 versus 0.05 ± 0.02 intensity units [IU]/s; P = .0014) and between carcinoma and fibroadenoma (0.10 ± 0.03 versus 0.04 ± 0.01 IU/s; P = .0044), whereas differences between carcinomas and cysts were found to be nonsignificant. In conclusion, a parametric imaging method for characterization of breast lesions using the high contrast to tissue signal provided by SHI has been developed. While the preliminary sample size was limited, results show potential for breast lesion characterization based on perfusion flow parameters.

  12. Quantitative analysis of vascular heterogeneity in breast lesions using contrast-enhanced 3-D harmonic and subharmonic ultrasound imaging.

    Science.gov (United States)

    Sridharan, Anush; Eisenbrey, John R; Machado, Priscilla; Ojeda-Fournier, Haydee; Wilkes, Annina; Sevrukov, Alexander; Mattrey, Robert F; Wallace, Kirk; Chalek, Carl L; Thomenius, Kai E; Forsberg, Flemming

    2015-03-01

    Ability to visualize breast lesion vascularity and quantify the vascular heterogeneity using contrast-enhanced 3-D harmonic (HI) and subharmonic (SHI) ultrasound imaging was investigated in a clinical population. Patients (n = 134) identified with breast lesions on mammography were scanned using power Doppler imaging, contrast-enhanced 3-D HI, and 3-D SHI on a modified Logiq 9 scanner (GE Healthcare). A region of interest corresponding to ultrasound contrast agent flow was identified in 4D View (GE Medical Systems) and mapped to raw slice data to generate a map of time-intensity curves for the lesion volume. Time points corresponding to baseline, peak intensity, and washout of ultrasound contrast agent were identified and used to generate and compare vascular heterogeneity plots for malignant and benign lesions. Vascularity was observed with power Doppler imaging in 84 lesions (63 benign and 21 malignant). The 3-D HI showed flow in 8 lesions (5 benign and 3 malignant), whereas 3-D SHI visualized flow in 68 lesions (49 benign and 19 malignant). Analysis of vascular heterogeneity in the 3-D SHI volumes found benign lesions having a significant difference in vascularity between central and peripheral sections (1.71 ± 0.96 vs. 1.13 ± 0.79 dB, p < 0.001, respectively), whereas malignant lesions showed no difference (1.66 ± 1.39 vs. 1.24 ± 1.14 dB, p = 0.24), indicative of more vascular coverage. These preliminary results suggest quantitative evaluation of vascular heterogeneity in breast lesions using contrast-enhanced 3-D SHI is feasible and able to detect variations in vascularity between central and peripheral sections for benign and malignant lesions.

  13. Contrast-Enhanced Subharmonic and Harmonic Ultrasound of Renal Masses Undergoing Percutaneous Cryoablation.

    Science.gov (United States)

    Eisenbrey, John R; Shaw, Colette M; Lyshchik, Andrej; Machado, Priscilla; Lallas, Costas D; Trabulsi, Edouard J; Merton, Daniel A; Fox, Traci B; Liu, Ji-Bin; Brown, Daniel B; Forsberg, Flemming

    2015-07-01

    The objective of this study was to evaluate and compare contrast-enhanced subharmonic and harmonic ultrasound as tools for characterizing solid renal masses and monitoring their response to cryoablation therapy. Sixteen patients undergoing percutaneous ablation of a renal mass provided informed consent to undergo ultrasound examinations the morning before and approximately 4 months after cryoablation. Ultrasound contrast parameters during pretreatment imaging were compared to biopsy results obtained during ablation (n = 13). Posttreatment changes were evaluated by a radiologist and compared to contrast-enhanced magnetic resonance imaging (MRI)/computed tomography (CT) follow-up. All masses initially showed heterogeneous enhancement with both subharmonic and harmonic ultrasound. Early contrast washout in the mass relative to the cortex was observed in 6 of 9 malignant and 0 of 4 benign lesions in subharmonic mode and 8 of 9 malignant and 1 of 4 benign lesions in harmonic imaging. In cases where the lesion was adequately visualized at follow-up (n = 12), subharmonic and harmonic ultrasound showed accuracies of 83% and 75%, respectively, in predicting treatment outcome. Although harmonic imaging showed less overall error, no significant differences (P > .29) in ablation cavity volumes were observed between MRI/CT and either contrast-imaging mode. Subharmonic and harmonic contrast-enhanced ultrasound may be a safe and accurate imaging alternative for characterizing renal masses and evaluating their response to cryoablation therapy. Although subharmonic imaging was more accurate in detecting effective cryoablation, harmonic imaging was superior in quantifying ablation cavity volumes. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  14. High and low frequency subharmonic imaging of angiogenesis in a murine breast cancer model

    OpenAIRE

    Dahibawkar, Manasi; Forsberg, Mark A.; Gupta, Aditi; Jaffe, Samantha; Dulin, Kelly; Eisenbrey, John R.; Halldorsdottir, Valgerdur G.; Forsberg, Anya I.; Dave, Jaydev K.; Marshall, Andrew; Machado, Priscilla; Fox, Traci B.; Liu, Ji-Bin; Forsberg, Flemming

    2015-01-01

    This project compared quantifiable measures of tumor vascularity obtained from contrast-enhanced high frequency (HF) and low frequency (LF) subharmonic ultrasound imaging (SHI) to 3 immunohistochemical markers of angiogenesis in a murine breast cancer model (since angiogenesis is an important marker of malignancy and the target of many novel cancer treatments). Nineteen athymic, nude, female rats were implanted with 5×106 breast cancer cells (MDA-MB-231) in the mammary fat pad. The contrast a...

  15. Self-demodulation effect on subharmonic response of ultrasound contrast agent

    Science.gov (United States)

    Daeichin, V.; Faez, T.; Needles, A.; Renaud, G.; Bosch, J. G.; van der Steen, A. F. W.; de Jong, N.

    2012-03-01

    In this work the use of the self-demodulation (S-D) signal as a mean of microbubble excitation at the subharmonic (SH) frequency to enhance the SH emission of ultrasound contrast agent (UCA) is studied. SH emission from the UCA is of interest since it is produced only by the UCA and is free of the artifacts produced in harmonic imaging modes. The S-D wave is a low-frequency signal produced by nonlinear propagation of an ultrasound wave in the medium. Single element transducer experiments and numerical simulations were conducted at 10 MHz to study the effect of the S-D signal on the SH response of the UCA by modifying the envelope of the excitation bursts. For 6 and 20 transmitted cycles, the SH response is increased up to 25 dB and 22 dB because of the S-D stimulation for a burst with a rectangular envelope compared with a Gaussian envelope burst. Such optimized excitations were used in an array-based micro-ultrasound system (Vevo 2100, VisualSonics Inc., Toronto, ON, Canada) at 18 MHz for in vitro validation of SH imaging. This study suggests that a suitable design of the envelope of the transmit excitation to generate a S-D signal at the SH frequency can enhance the SH emission of UCA and real-time SH imaging is feasible with shorter transmit burst (6- cycle) and low acoustic pressure (~150 KPa) at high frequencies (>15 MHz).

  16. Processing of subharmonic signals from ultrasound contrast agents to determine ambient pressures.

    Science.gov (United States)

    Dave, Jaydev K; Halldorsdottir, Valgerdur G; Eisenbrey, John R; Forsberg, Flemming

    2012-04-01

    Subharmonic-aided pressure estimation (SHAPE) is a technique that utilizes the subharmonic emissions, occurring at half the insonation frequency, from ultrasound contrast agents to estimate ambient pressures. The purpose of this work was to compare the performance of different processing techniques for the raw radiofrequency (rf) data acquired for SHAPE. A closed loop flow system was implemented circulating reconstituted Sonazoid (GE Healthcare, Oslo, Norway; 0.2 ml for 750 ml diluent) and the beam-formed unprocessed rf data were obtained from a 4 mm diameter lumen of a Doppler flow phantom (ATS Laboratories, Inc., Bridgeport, CT) using a SonixRP scanner (Ultrasonix, Richmond, BC, Canada). The transmit frequency and incident acoustic pressures were set to 2.5 MHz and 0.22 MPa, respectively, in order to elicit Sonazoid subharmonic emissions that are ambient-pressure sensitive. The time-varying ambient pressures within the flow phantom were recorded by a Millar pressure catheter. Four techniques for extracting the subharmonic amplitude from the rf data were tested along with two noise filtering techniques to process this data. Five filter orders were tested for the noise removing filters. The performance was evaluated based on the least root-mean-square errors reported after linear least-square regression analyses of the subharmonic data and the pressure catheter data and compared using a repeated ANOVA. When the subharmonic amplitudes were extracted as the mean value within a 0.2 MHz bandwidth about 1.25 MHz and when the resulting temporally-varying subharmonic signal was median filtered with an order of 500, the filtered subharmonic signal significantly predicted the ambient pressures (r2 = 0.90; p < 0.001) with the least error. The resulting root mean square and mean absolute errors were 8.16 +/- 0.26 mmHg and 6.70 +/- 0.17 mmHg, respectively. Thus, median processing the subharmonic data extracted as the mean value within a 0.2 MHz bandwidth about the theoretical

  17. Noninvasive Ambient Pressure Estimation using Ultrasound Contrast Agents -- Invoking Subharmonics for Cardiac and Hepatic Applications

    Science.gov (United States)

    Dave, Jaydev K.

    Ultrasound contrast agents (UCAs) are encapsulated microbubbles that provide a source for acoustic impedance mismatch with the blood, due to difference in compressibility between the gas contained within these microbubbles and the blood. When insonified by an ultrasound beam, these UCAs act as nonlinear scatterers and enhance the echoes of the incident pulse, resulting in scattering of the incident ultrasound beam and emission of fundamental (f0), subharmonic (f0/2), harmonic (n*f0; n ∈ N) and ultraharmonic (((2n-1)/2)*f0; n ∈ N & n > 1) components in the echo response. A promising approach to monitor in vivo pressures revolves around the fact that the ultrasound transmit and receive parameters can be selected to induce an ambient pressure amplitude dependent subharmonic signal. This subharmonic signal may be used to estimate ambient pressure amplitude; such technique of estimating ambient pressure amplitude is referred to as subharmonic aided pressure estimation or SHAPE. This project develops and evaluates the feasibility of SHAPE to noninvasively monitor cardiac and hepatic pressures (using commercially available ultrasound scanners and UCAs) because invasive catheter based pressure measurements are used currently for these applications. Invasive catheter based pressure measurements pose risk of introducing infection while the catheter is guided towards the region of interest in the body through a percutaneous incision, pose risk of death due to structural or mechanical failure of the catheter (which has also triggered product recalls by the USA Food and Drug Administration) and may potentially modulate the pressures that are being measured. Also, catheterization procedures require fluoroscopic guidance to advance the catheter to the site of pressure measurements and such catheterization procedures are not performed in all clinical centers. Thus, a noninvasive technique to obtain ambient pressure values without the catheterization process is clinically

  18. Comparing Quantitative Immunohistochemical Markers of Angiogenesis to Contrast-Enhanced Subharmonic Imaging.

    Science.gov (United States)

    Gupta, Aditi; Forsberg, Mark A; Dulin, Kelly; Jaffe, Samantha; Dave, Jaydev K; Halldorsdottir, Valgerdur G; Marshall, Andrew; Forsberg, Anya I; Eisenbrey, John R; Machado, Priscilla; Fox, Traci B; Liu, Ji-Bin; Forsberg, Flemming

    2016-09-01

    Different methods for obtaining tumor neovascularity parameters based on immunohistochemical markers were compared to contrast-enhanced subharmonic imaging (SHI). Eighty-five athymic nude female rats were implanted with 5 × 10(6) breast cancer cells (MDA-MB-231) in the mammary fat pad. The contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) was injected, and SHI was performed using a modified Sonix RP scanner (Analogic Ultrasound, Richmond, British Columbia, Canada) with a L9-4 linear array (transmitting/receiving frequencies, 8/4 MHz). Afterward, specimens were stained for endothelial cells (CD31), vascular endothelial growth factor (VEGF), and cyclooxygenase 2 (COX-2). Tumor neovascularity was assessed in 4 different ways using a histomorphometry system (×100 magnification: (1) over the entire tumor; (2) in small sub-regions of interest (ROIs); (3) in the tumor periphery and centrally; and (4) in 3 regions of maximum marker expression (so-called hot spots). Results from specimens and from SHI were compared by linear regression. Fifty-four rats (64%) showed tumor growth, and 38 were successfully imaged. Subharmonic imaging depicted the tortuous morphologic characteristics of tumor neovessels and delineated small areas of necrosis. The immunohistochemical markers did not correlate with SHI measures over the entire tumor area or over small sub-ROIs (P > .18). However, when the specimens were subdivided into central and peripheral regions, COX-2 and VEGF correlated with SHI in the periphery (r = -0.42; P = .005; and r = -0.32; P = .049, respectively). When comparing quantitative contrast measures of tumor neovascularity to immunohistochemical markers of angiogenesis in xenograft models, ROIs corresponding to the biologically active region should be used to account for tumor heterogeneity.

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures ... limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  20. High and low frequency subharmonic imaging of angiogenesis in a murine breast cancer model.

    Science.gov (United States)

    Dahibawkar, Manasi; Forsberg, Mark A; Gupta, Aditi; Jaffe, Samantha; Dulin, Kelly; Eisenbrey, John R; Halldorsdottir, Valgerdur G; Forsberg, Anya I; Dave, Jaydev K; Marshall, Andrew; Machado, Priscilla; Fox, Traci B; Liu, Ji-Bin; Forsberg, Flemming

    2015-09-01

    This project compared quantifiable measures of tumor vascularity obtained from contrast-enhanced high frequency (HF) and low frequency (LF) subharmonic ultrasound imaging (SHI) to 3 immunohistochemical markers of angiogenesis in a murine breast cancer model (since angiogenesis is an important marker of malignancy and the target of many novel cancer treatments). Nineteen athymic, nude, female rats were implanted with 5×10(6) breast cancer cells (MDA-MB-231) in the mammary fat pad. The contrast agent Definity (Lantheus Medical Imaging, N Billerica, MA) was injected in a tail vein (dose: 180μl/kg) and LF pulse-inversion SHI was performed with a modified Sonix RP scanner (Analogic Ultrasound, Richmond, BC, Canada) using a L9-4 linear array (transmitting/receiving at 8/4MHz in SHI mode) followed by HF imaging with a Vevo 2100 scanner (Visualsonics, Toronto, ON, Canada) using a MS250 linear array transmitting and receiving at 24MHz. The radiofrequency data was filtered using a 4th order IIR Butterworth bandpass filter (11-13MHz) to isolate the subharmonic signal. After the experiments, specimens were stained for endothelial cells (CD31), vascular endothelial growth factor (VEGF) and cyclooxygenase-2 (COX-2). Fractional tumor vascularity was calculated as contrast-enhanced pixels over all tumor pixels for SHI, while the relative area stained over total tumor area was calculated from specimens. Results were compared using linear regression analysis. Out of 19 rats, 16 showed tumor growth (84%) and 11 of them were successfully imaged. HF SHI demonstrated better resolution, but weaker signals than LF SHI (0.06±0.017 vs. 0.39±0.059; p<0.001). The strongest overall correlation in this breast cancer model was between HF SHI and VEGF (r=-0.38; p=0.03). In conclusion, quantifiable measures of tumor neovascularity derived from contrast-enhanced HF SHI appear to be a better method than LF SHI for monitoring angiogenesis in a murine xenograft model of breast cancer

  1. Subharmonic and Endoscopic Contrast Imaging of Pancreatic Masses: A Pilot Study.

    Science.gov (United States)

    Forsberg, Flemming; Stanczak, Maria; Lyshchik, Andrej; Loren, David; O'Kane, Patrick; Siddiqui, Ali; Kowalski, Thomas E; Miller, Cynthia; Fox, Traci; Liu, Ji-Bin; Eisenbrey, John R

    2017-07-06

    To use subharmonic imaging (SHI) to depict the vascularity of pancreatic masses compared to contrast-enhanced endoscopic ultrasound (EUS) and pathologic results. Sixteen patients scheduled for biopsy of a pancreatic mass were enrolled in an Institutional Review Board-approved study. Pulse-inversion SHI (transmitting/receiving at 2.5/1.25 MHz) was performed on a LOGIQ 9 system (GE Healthcare, Milwaukee, WI) with a 4C transducer, whereas contrast harmonic EUS (transmitting/receiving at 4.7/9.4 MHz) was performed with a radial endoscope (GF-UTC180; Olympus Corporation, Tokyo, Japan) connected to a ProSound SSD α-10 scanner (Hitachi Aloka, Tokyo, Japan). Two injections of the contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) were administrated (0.3-0.4 and 0.6-0.8 mL for EUS and SHI, respectively). Contrast-to-tissue ratios (CTRs) in the mass and an adjacent vessel were calculated. Four physicians independently scored the images (benign to malignant) for diagnostic accuracy and inter-reader agreement. One patient dropped out before imaging, leaving 11 adenocarcinomas, 1 gastrointestinal stromal tumor with pancreatic infiltration, and 3 benign masses. Marked subharmonic signals were obtained in all patients, with intratumoral blood flow clearly visualized with SHI. Significantly greater CTRs were obtained in the masses with SHI than with EUS (mean ± SD, 1.71 ± 1.63 versus 0.63 ± 0.89; P = .016). There were no differences in the CTR in the surrounding vessels or when grouped by pathologic results (P > .60). The accuracies for contrast EUS and SHI were low (<53%), albeit with a greater κ value for SHI (0.34) than for EUS (0.13). Diagnostic accuracy of contrast EUS and transabdominal SHI for assessment of pancreatic masses was quite low in this pilot study. However, SHI had improved tumoral CTRs relative to contrast EUS. © 2017 by the American Institute of Ultrasound in Medicine.

  2. Assessing algorithms for defining vascular architecture in subharmonic images of breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Eisenbrey, John R; Joshi, Neha; Dave, Jaydev K; Forsberg, Flemming, E-mail: Flemming.Forsberg@jefferson.edu [Department of Radiology, Thomas Jefferson University, 137 South 10th St, Philadelphia, PA 19107 (United States)

    2011-02-21

    The ability to accurately and non-invasively characterize breast lesions and their vasculature would greatly limit the number of unneeded biopsies performed annually. Subharmonic ultrasound imaging (SHI) allows exclusive imaging of vasculature in real time, while completely suppressing tissue signals. Previously, cumulative maximum intensity (CMI) projections of SHI data were shown to be useful for characterization, but lacked means of quantification. In this study we investigate three potential thinning algorithms for defining breast lesion architecture. Sequential thinning, parallel thinning, and distance transformation algorithms were compared using 40 in vitro test images. Sequential thinning was selected due to superior connectivity, minimal rotational variance, and sufficient data reduction. This algorithm was then applied to 16 CMI SHI images of breast lesions, out of which 13 were successfully skeletonized. Average bifurcations were 9.8 {+-} 8.18 and 6.9 {+-} 6.50 in malignant and benign lesions, respectively (p > 0.60). Average vessel-chain length was 88.9 {+-} 79.10 pixels versus 63.2 {+-} 45.65 pixels in malignant versus benign lesions (p > 0.40). While the sequential thinning algorithm was promising for quantifying breast vasculature, its ability to significantly differentiate between malignant and benign lesions in this study was limited by a high degree of variability and limited sample size.

  3. Assessing algorithms for defining vascular architecture in subharmonic images of breast lesions.

    Science.gov (United States)

    Eisenbrey, John R; Joshi, Neha; Dave, Jaydev K; Forsberg, Flemming

    2011-02-21

    The ability to accurately and non-invasively characterize breast lesions and their vasculature would greatly limit the number of unneeded biopsies performed annually. Subharmonic ultrasound imaging (SHI) allows exclusive imaging of vasculature in real time, while completely suppressing tissue signals. Previously, cumulative maximum intensity (CMI) projections of SHI data were shown to be useful for characterization, but lacked means of quantification. In this study we investigate three potential thinning algorithms for defining breast lesion architecture. Sequential thinning, parallel thinning, and distance transformation algorithms were compared using 40 in vitro test images. Sequential thinning was selected due to superior connectivity, minimal rotational variance, and sufficient data reduction. This algorithm was then applied to 16 CMI SHI images of breast lesions, out of which 13 were successfully skeletonized. Average bifurcations were 9.8 ± 8.18 and 6.9 ± 6.50 in malignant and benign lesions, respectively (p > 0.60). Average vessel-chain length was 88.9 ± 79.10 pixels versus 63.2 ± 45.65 pixels in malignant versus benign lesions (p > 0.40). While the sequential thinning algorithm was promising for quantifying breast vasculature, its ability to significantly differentiate between malignant and benign lesions in this study was limited by a high degree of variability and limited sample size.

  4. Real-time monitoring of focused ultrasound blood-brain barrier opening via subharmonic acoustic emission detection: implementation of confocal dual-frequency piezoelectric transducers.

    Science.gov (United States)

    Tsai, Chih-Hung; Zhang, Jia-Wei; Liao, Yi-Yi; Liu, Hao-Li

    2016-04-07

    Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contrast-enhanced imaging confirmation after focused ultrasound (FUS) exposure serves as a post-operative indicator of the effectiveness of FUS-BBB opening, however, an indicator that can concurrently report the BBB status and BBB-opening effectiveness is required to provide effective feedback to implement this treatment clinically. In this study, we demonstrate the use of subharmonic acoustic emission detection with implementation on a confocal dual-frequency piezoelectric ceramic structure to perform real-time monitoring of FUS-BBB opening. A confocal dual-frequency (0.55 MHz/1.1 MHz) focused ultrasound transducer was designed. The 1.1 MHz spherically-curved ceramic was employed to deliver FUS exposure to induce BBB-opening, whereas the outer-ring 0.55 MHz ceramic was employed to detect the subharmonic acoustic emissions originating from the target position. In stage-1 experiments, we employed spectral analysis and performed an energy spectrum density (ESD) calculation. An optimized 0.55 MHz ESD level change was shown to effectively discriminate the occurrence of BBB-opening. Wideband acoustic emissions received from 0.55 MHz ceramics were also analyzed to evaluate its correlations with erythrocyte extravasations. In stage-2 real-time monitoring experiments, we applied the predetermined ESD change as a detection threshold in PC-controlled algorithm to predict the FUS exposure intra-operatively. In stage-1 experiment, we showed that subharmonic ESD presents distinguishable dynamics between intact BBB and opened BBB, and therefore a threshold ESD change level (5.5 dB) can be identified for BBB-opening prediction. Using this ESD change threshold detection as a

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, ... top of page What are some common uses of the procedure? Ultrasound examinations can help to diagnose ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of the ... of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or sonography , ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and ... be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... data into 3-D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and produces pictures of the inside of the body using ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of the body. It is ... Imaging? Ultrasound is safe and painless, and produces pictures of the inside of the body using sound ...

  15. Intravascular ultrasound chirp imaging

    NARCIS (Netherlands)

    Maresca, D.; Jansen, K.; Renaud, G.; Van Soest, G.; Li, X.; Zhou, Q.; De Jong, N.; Shung, K.K.; Van der Steen, A.F.W.

    2012-01-01

    We demonstrate the feasibility of intravascular ultrasound (IVUS) chirp imaging as well as chirp reversal ultrasound contrast imaging at intravascular ultrasound frequency. Chirp excitations were emitted with a 34?MHz single crystal intravascular transducer and compared to conventional

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3- ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called ... terms of the distance traveled per unit of time, rather than as a color picture. It can ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... Transvaginal ultrasound. The transducer is inserted into a woman's vagina to view the uterus and ovaries. top ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... illness. Ultrasound is used to help physicians evaluate symptoms such as: pain swelling infection Ultrasound is a ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... at home and wear loose, comfortable clothing. You may be asked to wear a gown. What is ... into 3-D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... when the scan begins. top of page What does the equipment look like? Ultrasound scanners consist of ... poorly suited for ultrasound. top of page How does the procedure work? Ultrasound imaging is based on ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... data into 3-D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ... usually stain or discolor clothing. In some ultrasound studies, the transducer is attached to a probe and ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of the abdomen ... limitations of Abdominal Ultrasound Imaging? What is Abdominal Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the limitations of General Ultrasound Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal ...

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... are the limitations of Abdominal Ultrasound Imaging? What is Abdominal Ultrasound Imaging? Ultrasound is safe and painless, ... top of page What are some common uses of the procedure? Abdominal ultrasound imaging is performed to ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... tissues that do not show up well on x-ray images. Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... needed for ultrasound examinations. top of page What does the ultrasound equipment look like? Ultrasound scanners consist ... poorly suited for ultrasound. top of page How does the procedure work? Ultrasound imaging is based on ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles involved in the ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... will share the results with you. In some cases, the radiologist may discuss results with you at ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... is performed using the same transducer. Rarely, young children may need to be sedated in order to ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... for a procedure like angioplasty . top of page How should I prepare? You should wear comfortable, loose- ... are poorly suited for ultrasound. top of page How does the procedure work? Ultrasound imaging is based ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... In most cases, barium exams, CT scanning , and MRI are the methods of choice in such a ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in ... including the abdominal aorta and its major ... of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... radiology examinations) or sonographer will apply a warm water-based gel to the area of the body ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... creates a real-time picture on the monitor. One or more frames of the moving pictures are ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... time imaging, making it a good tool for guiding minimally invasive procedures such as needle biopsies and ... here Images × Image Gallery General ultrasound procedure View full size with caption Pediatric Content Some imaging tests ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of General Ultrasound Imaging? Ultrasound waves are ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... have a personal story about radiology? Share your patient story here Images × Image Gallery General ultrasound procedure View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  3. Medical ultrasound imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2007-01-01

    The paper gives an introduction to current medical ultrasound imaging systems. The basics of anatomic and blood flow imaging are described. The properties of medical ultrasound and its focusing are described, and the various methods for two- and three-dimensional imaging of the human anatomy...... are shown. Both systems using linear and non-linear propagation of ultrasound are described. The blood velocity can also be non-invasively visualized using ultrasound and the basic signal processing for doing this is introduced. Examples for spectral velocity estimation, color flow maging and the new vector...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Abdominal ultrasound imaging is performed to evaluate ... for ultrasound examinations. top of page What does the ultrasound equipment look like? Ultrasound scanners consist of ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... then uses those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured in real-time, they can show ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... pictures are typically captured as still images. Short video loops of the images may also be saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of blood cells causes a change in pitch ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Children's (pediatric) abdominal ultrasound imaging produces pictures ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... computer or television monitor. The image is created based on the amplitude (loudness), frequency (pitch) and time ... How does the procedure work? Ultrasound imaging is based on the same principles involved in the sonar ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery General ultrasound procedure View full size with ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  12. Abdominal ultrasound (image)

    Science.gov (United States)

    Abdominal ultrasound is a scanning technique used to image the interior of the abdomen. Like the X- ... use high frequency sound waves to produce an image and do not expose the individual to radiation. ...

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of Abdominal Ultrasound Imaging? What is Abdominal Ultrasound Imaging? Ultrasound is safe and painless, and produces pictures of the inside of the body using ...

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of Abdominal Ultrasound Imaging? What is Abdominal Ultrasound Imaging? Ultrasound is safe and ... as the liver or kidneys. top of page What are some common uses of the procedure? Abdominal ...

  15. Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav; Gammelmark, Kim Løkke

    2006-01-01

    The paper describes the use of synthetic aperture (SA) imaging in medical ultrasound. SA imaging is a radical break with today's commercial systems, where the image is acquired sequentially one image line at a time. This puts a strict limit on the frame rate and the possibility of acquiring...... of SA imaging. Due to the complete data set, it is possible to have both dynamic transmit and receive focusing to improve contrast and resolution. It is also possible to improve penetration depth by employing codes during ultrasound transmission. Data sets for vector flow imaging can be acquired using...... short imaging sequences, whereby both the correct velocity magnitude and angle can be estimated. A number of examples of both phantom and in-vivo SA images will be presented measured by the experimental ultrasound scanner RASMUS to demonstrate the many benefits of SA imaging....

  16. Portable Ultrasound Imaging

    DEFF Research Database (Denmark)

    di Ianni, Tommaso

    This PhD project investigates hardware strategies and imaging methods for hand-held ultrasound systems. The overall idea is to use a wireless ultrasound probe linked to general-purpose mobile devices for the processing and visualization. The approach has the potential to reduce the upfront costs ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of the body. It is used to help diagnose the causes of pain, swelling and infection in the body’s internal organs and to examine a baby in pregnant women and the brain and hips in infants. It’s also used to ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... radiation exposure to the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Most ultrasound scanning ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... time, rather than as a color picture. It can also convert blood flow information into a distinctive ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement ... by a computer, which in turn creates a real-time picture on the monitor. One or more ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible on a video display screen ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible ... principles involved in the sonar used by bats, ships and fishermen. When a sound wave strikes an ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... to sample cells from an abnormal area for laboratory testing. image the breasts and guide biopsy of ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast ... or for a referral to a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... an abnormal area for laboratory testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart conditions, ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of the inside of the body. It is used to help ... safe and painless, and produces pictures of the inside of the body using sound waves. Ultrasound imaging, ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... terms of the distance traveled per unit of time, rather than as a color picture. It can ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... biopsies , in which needles are used to sample cells from an abnormal area for laboratory testing. image ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... examination is complete, you may be asked to dress and wait while the ultrasound images are reviewed. ... the following text box: Comment: E-mail: Area code: Phone no: Thank you! Do you have a ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... procedure work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ... the transducer. Doppler sonography is performed using the same transducer. Rarely, young children may need to be ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... knowledge about the speed and volume of blood flow gained from a Doppler ultrasound image, the physician can often determine whether a patient is a good candidate for a procedure like angioplasty . top of ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... General ultrasound procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test ... that allows the physician to see and evaluate blood flow through arteries and veins in the abdomen, ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... blood flow (such as clots) narrowing of vessels tumors and congenital vascular malformations reduced or absent blood ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... over time. Follow-up examinations are sometimes the best way to see if treatment is working or ... methods of choice in such a setting. Large patients are more difficult to image by ultrasound because ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... biopsies , in which needles are used to sample cells from an abnormal area for laboratory testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the ... may be important in some situations. Spectral Doppler displays blood flow measurements graphically, in terms of the ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... can often determine whether a patient is a good candidate for a procedure like angioplasty . top of ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of ... 30 minutes. top of page What will my child experience during and after the procedure? Ultrasound examinations ...

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... proper blood flow into it. top of page How should we prepare for an abdominal ultrasound exam? ... are poorly suited for ultrasound. top of page How does the procedure work? Ultrasound imaging is based ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement ... of vomiting in young infants Because ultrasound provides real-time images, images that are renewed continuously, it ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... vomiting in young infants Because ultrasound provides real-time images, images that are renewed continuously, it also ...

  6. Ultrasound skin imaging.

    Science.gov (United States)

    Alfageme Roldán, F

    2014-12-01

    The interaction of high-frequency ultrasound waves with the skin provides the basis for noninvasive, fast, and accessible diagnostic imaging. This tool is increasingly used in skin cancer and inflammatory conditions as well as in cosmetic dermatology. This article reviews the basic principles of skin ultrasound and its applications in the different areas of dermatology. Copyright © 2013 Elsevier España, S.L.U. y AEDV. All rights reserved.

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the ... tissues that do not show up well on x-ray images. Ultrasound is the preferred imaging modality for ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that ...

  10. Deconvolution of ultrasound images

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1992-01-01

    Based on physical models, it is indicated that the received pressure field in ultrasound B-mode images can be described by a convolution between a tissue reflection signal and the emitted pressure field. This result is used in a description of current image formation and in formulating a new...

  11. Strategy of high efficiency and refined high-intensity focused ultrasound and ultrasound monitoring imaging of thermal lesion and cavitation

    Science.gov (United States)

    Wan, Mingxi; Zhang, Siyuan; Lu, Mingzhu; Hu, Hong; Jing, Bowen; Liu, Runna; Zhong, Hui

    2017-03-01

    We proposed that high efficiency high-intensity focused ultrasound (HIFU) could be achieved by using a splitting transducer with various frequencies and focusing patterns, and explored the feasibility of using ultrafast active cavitation imaging (UACI), pulse inversion (PI) sub-harmonic cavitation imaging and bubble wavelet transform imaging for monitoring of cavitation during HIFU, as well as the ultrasonic B-mode images, differential integrated backscatter (IBS) images, Nakagami images and elastography for monitoring HIFU-induced lesion. The use of HIFU splitting transducer had the potential to increase the size of the thermal lesion in a shorter duration and may improve the ablation efficiency of HIFU and would shorten the exposure duration significantly. The spatial-temporal evolution of residual cavitation bubbles at the tissue-water interface was obtained by UACI and the results showed that the UACI had a frame rate high enough to capture the transient behavior of the cavitation bubbles. The experiments demonstrated that comparing with normal sub-harmonic and PI harmonic images, PI sub-harmonic images had higher sensitivity and CTR, which was conducive to showing cavitation bubbles. The CTR would be further improved by combining PI ultrafast plane wave transmitting with cavitation bubble wavelet transform.

  12. Effect of self-demodulation on the subharmonic response of contrast agent microbubbles

    NARCIS (Netherlands)

    V. Daeichin (Verya); T. Faez (Telli); G. Renaud (G.); J.G. Bosch (Hans); A.F.W. van der Steen (Ton); N. de Jong (Nico)

    2012-01-01

    textabstractSubharmonic (SH) emission from the ultrasound contrast agent (UCA) is of interest since it is produced only by the UCA and not by tissue, opposite to harmonic imaging modes where both tissue and microbubble show harmonics. In this work, the use of the self-demodulation (S-D) signal as a

  13. Monitoring Neoadjuvant Chemotherapy for Breast Cancer by Using Three-dimensional Subharmonic Aided Pressure Estimation and Imaging with US Contrast Agents: Preliminary Experience.

    Science.gov (United States)

    Nam, Kibo; Eisenbrey, John R; Stanczak, Maria; Sridharan, Anush; Berger, Adam C; Avery, Tiffany; Palazzo, Juan P; Forsberg, Flemming

    2017-10-01

    Purpose To determine whether three-dimensional subharmonic aided pressure estimation (SHAPE) and subharmonic imaging can help predict the response of breast cancer to neoadjuvant chemotherapy. Materials and Methods In this HIPAA-compliant prospective study, 17 women (age range, 45-70 years) scheduled to undergo neoadjuvant therapy for breast cancer underwent ultrasonography (US) immediately before therapy and at completion of 10%, 60%, and 100% of chemotherapy. All patients provided written informed consent. At each examination, radiofrequency data were collected from SHAPE and subharmonic imaging during infusion of a US contrast agent. Maximum-frequency magnitude and mean intensity were calculated for SHAPE and subharmonic imaging. The signal differences in the tumor relative to the surrounding area were compared with the final treatment response by using the Student t test. Results Four patients left the study, and data from two patients were discarded because of technical problems. Eight patients completed the entire imaging protocol, and an additional three patients dropped out after the imaging session at completion of 10% of chemotherapy as a result of disease progression (these patients were counted as nonresponders). Patients' imaging outcomes consisted of six responders (tumor volume reduction >90%) and five partial responders or nonresponders. The results at completion of 10% of therapy showed that the subharmonic signal increased more in the tumor than in the surrounding area for responders than in partial responders or nonresponders (mean ± standard deviation, 3.23 dB ± 1.41 vs -0.88 dB ± 1.46 [P = .001], respectively, for SHAPE and 1.32 dB ± 0.73 vs -0.82 dB ± 0.88 [P = .002], respectively, for subharmonic imaging). Moreover, three patients whose tumor measurements initially increased were correctly predicted to be responders with SHAPE and subharmonic imaging after completion of 10% of therapy. Conclusion SHAPE and subharmonic imaging have the

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... kidneys bladder testicles ovaries uterus Abdominal ultrasound images can be used to help diagnose appendicitis in children. ...

  15. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... improve the quality of the images. A clear water-based gel is applied to the area of ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... patients eyes thyroid and parathyroid glands scrotum (testicles) brain in infants hips in infants spine in infants Ultrasound is also used to: guide procedures such as needle biopsies , in which needles are used to sample cells from an abnormal area for laboratory testing. image ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... they move through vessels. The movement of blood cells causes a change in pitch of the reflected sound waves (called the Doppler ... Do you have a personal ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... medicine, ultrasound is used to detect changes in appearance, size or contour of organs, tissues, and vessels ... your body. The transducer is placed on the body and moved back and forth over the area of interest until the desired images are captured. There is usually no discomfort from ...

  19. Recursive ultrasound imaging

    DEFF Research Database (Denmark)

    2000-01-01

    A method and an apparatus for recursive ultrasound imaging is presented. The method uses a Synthetic Transmit Aperture, but unlike previous approaches a new frame is created at every pulse emission. In receive, parallel beam forming is implemented. The beam formed RF data is added to the previously...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... internal organs and to examine a baby in pregnant women and the brain and hips in infants. It’s ... imaging modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  1. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Abdominal Ultrasound Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal ...

  2. Stable and transient subharmonic emissions from isolated contrast agent microbubbles.

    Science.gov (United States)

    Biagi, Elena; Breschi, Luca; Vannacci, Enrico; Masotti, Leonardo

    2007-03-01

    Ultrasound contrast agents (UCAs) have been widely studied in recent years in order to improve and develop new, sophisticated imaging techniques for clinical applications. In order to improve the understanding of microbubble-ultrasound interactions, an acoustic dynamic characterization of UCA microbubble behavior was performed in this work using a high frame-rate acquiring and processing system. This equipment is connected to a commercial scanner that provides RF beam-formed data with a frame-rate of 30 Hz. Acquired RF sequences allows us to follow the dynamics of cavitation mechanisms in its temporal evolution during different insonifying conditions. The experimental setup allowed us to keep the bubbles free in a spatial region of the supporting medium, thus avoiding boundary effects that can alter the ultrasound field and the scattered echo from bubbles. The work focuses on the study of subharmonic emission from an isolated bubble of contrast agent. In particular, the acoustic pressure threshold for a subharmonic stable emission was evaluated for a subset of 50 microbubbles at 3.3 MHz and at 5 MHz of insonation frequencies. An unexpected second pressure threshold, which caused the stand still of the subharmonic emission, was detected at 3.3 MHz and 5 MHz excitation frequencies. A transient subharmonic emission, which is hypothesized as being related to the formation of new free gas bubbles, was detected during the ultrasound-induced destruction of microbubbles. An experimental procedure was devised in order to investigate these behaviors and several sequences of RF echo signals and the related spectra, acquired from an isolated bubble in different insonation conditions, are presented and discussed in this paper.

  3. Ultrasound Imaging Initiative

    Science.gov (United States)

    2003-01-01

    texture mapping hardware," IEEE Tranactions on Information Technology in Biomedicine, Submitted. [14] C.R. Castro Pareja , J.M. Jagadeesh and R. Shekhar...modulation in real-time three-dimensional sparse synthetic aperture ultrasound imaging systems "* Carlos R. Castro Pareja , Masters of Science, The Ohio...C.R. Castro Pareja , "An architecture for real-time image registration," M.S. Thesis, The Ohio State University, March 2002. 14. C.R. Castro Pareja , R

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles involved in the ...

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... will share the results with you. In some cases, the radiologist may discuss results with you at ...

  7. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Abdominal ultrasound imaging is performed to evaluate ... flow into it. top of page How should we prepare for an abdominal ultrasound exam? Your child ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... abdomen is a safe, noninvasive test that uses sound waves to produce a clear picture of the ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... In most cases, barium exams, CT scanning , and MRI are the methods of choice in such a ...

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... is a safe, noninvasive test that uses sound waves to produce a clear picture of the internal ... of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or sonography , ...

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... children. It is also valuable for evaluating the brain, spinal cord and hip joints in newborns ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound ...

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... a clear picture of the internal organs and blood vessels within your child’s abdomen. Ultrasound does not ... of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a ...

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... your child’s abdomen. Ultrasound does not use ionizing radiation, has no known harmful effects, and is particularly ... an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... creates a real-time picture on the monitor. One or more frames of the moving pictures are ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  16. Ultrasound Imaging Initiative

    Science.gov (United States)

    2002-01-01

    diagnosis of breast diseases . Edinburgh, Scotland: Churchill, Livingstone, 1994, pp 50-73. 8. Fornage BD, Lorigan JG, Andry E: Fibroadenoma of the breast ...to distinguish between mammographically identified cystic and solid masses. The accuracy rate of breast ultrasound (US) has been reported to be 96...and post-processing algorithms. PARTIALLY COMPLETED - The breast imaging toolbox has been completed and refined. The automated diagnostic tool

  17. Pulse-Inversion Subharmonic Ultrafast Active Cavitation Imaging in Tissue Using Fast Eigenspace-Based Adaptive Beamforming and Cavitation Deconvolution.

    Science.gov (United States)

    Bai, Chen; Xu, Shanshan; Duan, Junbo; Jing, Bowen; Yang, Miao; Wan, Mingxi

    2017-08-01

    Pulse-inversion subharmonic (PISH) imaging can display information relating to pure cavitation bubbles while excluding that of tissue. Although plane-wave-based ultrafast active cavitation imaging (UACI) can monitor the transient activities of cavitation bubbles, its resolution and cavitation-to-tissue ratio (CTR) are barely satisfactory but can be significantly improved by introducing eigenspace-based (ESB) adaptive beamforming. PISH and UACI are a natural combination for imaging of pure cavitation activity in tissue; however, it raises two problems: 1) the ESB beamforming is hard to implement in real time due to the enormous amount of computation associated with the covariance matrix inversion and eigendecomposition and 2) the narrowband characteristic of the subharmonic filter will incur a drastic degradation in resolution. Thus, in order to jointly address these two problems, we propose a new PISH-UACI method using novel fast ESB (F-ESB) beamforming and cavitation deconvolution for nonlinear signals. This method greatly reduces the computational complexity by using F-ESB beamforming through dimensionality reduction based on principal component analysis, while maintaining the high quality of ESB beamforming. The degraded resolution is recovered using cavitation deconvolution through a modified convolution model and compressive deconvolution. Both simulations and in vitro experiments were performed to verify the effectiveness of the proposed method. Compared with the ESB-based PISH-UACI, the entire computation of our proposed approach was reduced by 99%, while the axial resolution gain and CTR were increased by 3 times and 2 dB, respectively, confirming that satisfactory performance can be obtained for monitoring pure cavitation bubbles in tissue erosion.

  18. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Abdominal Ultrasound Imaging? Ultrasound waves are ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... appendix stomach/ pylorus liver gallbladder spleen pancreas intestines kidneys bladder testicles ovaries uterus Abdominal ultrasound images can be used to help diagnose appendicitis ...

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  2. Ultrasound imaging velocimetry : a review

    NARCIS (Netherlands)

    Poelma, C.

    2017-01-01

    Whole-field velocity measurement techniques based on ultrasound imaging (a.k.a. ‘ultrasound imaging velocimetry’ or ‘echo-PIV’) have received significant attention from the fluid mechanics community in the last decade, in particular because of their ability to obtain velocity fields in flows that

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... then uses those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured in real-time, they can show ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... pictures are typically captured as still images. Short video loops of the images may also be saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of blood cells causes a change in pitch ...

  6. Objective Image Quality Metrics for Ultrasound Imaging

    OpenAIRE

    Simpson, Cecilie Øinæs

    2009-01-01

    Objective evaluation of the image quality on ultrasound images is a comprehensive task due to the relatively low image quality compared to other imaging techniques. It is desirable to objectively determine the quality of ultrasound images since quantification of the quality removes the subjective evaluation which can lead to varying results. The scanner will also be more user friendly if the user is given feedback on the quality of the current image. This thesis has investigated in the obje...

  7. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - ... computer or television monitor. The image is created based on the amplitude (loudness), frequency (pitch) and time ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs such ... abdomen help determine causes of vomiting in young infants Because ultrasound provides real-time images, images that ...

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... diagnose heart conditions, and assess damage after a heart attack. Ultrasound is safe, noninvasive, and does not use ... heart failure, and to assess damage after a heart attack. Ultrasound of the heart is commonly called an “ ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... color picture. It can also convert blood flow information into a distinctive sound that can be heard ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... extremely safe and does not use any ionizing radiation. Ultrasound scanning gives a clear picture of soft ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Ultrasound examinations can help to diagnose a ... the scan begins. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... in infections With knowledge about the speed and volume of blood flow gained from a Doppler ultrasound ... the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. top of page ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... may also be saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of ... following text box: Comment: E-mail: Area code: Phone no: Thank you! Do you have a personal ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... may also be saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of ... care physician, or to the physician or other healthcare provider who requested the exam. Usually, the referring ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... radiation exposure to the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Most ultrasound scanning ...

  20. Ultrasound Imaging and its modeling

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2002-01-01

    Modern medical ultrasound scanners are used for imaging nearly all soft tissue structures in the body. The anatomy can be studied from gray-scale B-mode images, where the reflectivity and scattering strength of the tissues are displayed. The imaging is performed in real time with 20 to 100 images...

  1. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... various body organs such as the liver or kidneys. top of page What are some common uses ... appendix stomach/ pylorus liver gallbladder spleen pancreas intestines kidneys bladder testicles ovaries uterus Abdominal ultrasound images can ...

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... time imaging, making it a good tool for guiding minimally invasive procedures such as needle biopsies and ... radiologist scanning a boy's abdomen using ultrasound. View full size with caption Related Articles and Media Appendicitis ...

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Abdominal ultrasound imaging is performed to evaluate the: appendix stomach/ pylorus liver gallbladder spleen pancreas intestines kidneys ... as gallstones, kidney stones, abscesses or an inflamed appendix guide procedures such as biopsies, in which needles, ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? Abdominal ultrasound imaging is performed ... the scanner by a cord. Some exams may use different transducers (with different capabilities) during a single ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible on a video display screen ...

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible ... principles involved in the sonar used by bats, ships and fishermen. When a sound wave strikes an ...

  7. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... safe and painless, and produces pictures of the inside of the body using sound waves. Ultrasound imaging, ... capabilities) during a single exam. The transducer sends out high-frequency sound waves (that the human ear ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... examination is complete, you may be asked to dress and wait while the ultrasound images are reviewed. ... the following text box: Comment: E-mail: Area code: Phone no: Thank you! Do you have a ...

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... that uses sound waves to produce a clear picture of the internal organs and blood vessels within ... Imaging? Ultrasound is safe and painless, and produces pictures of the inside of the body using sound ...

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... appendicitis is the most common reason for emergency abdominal surgery. Ultrasound imaging can also: help a physician determine the source of abdominal pain, such as gallstones, kidney stones, abscesses or ...

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes ... specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... not use ionizing radiation, has no known harmful effects, and is particularly valuable for evaluating abdominal, pelvic ... in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured ...

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... procedure work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ... of concern. Doppler sonography is performed using the same transducer. When the examination is complete, you may ...

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  15. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  16. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... over time. Follow-up examinations are sometimes the best way to see if treatment is working or ... methods of choice in such a setting. Large patients are more difficult to image by ultrasound because ...

  17. Image processing in medical ultrasound

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian

    This Ph.D project addresses image processing in medical ultrasound and seeks to achieve two major scientific goals: First to develop an understanding of the most significant factors influencing image quality in medical ultrasound, and secondly to use this knowledge to develop image processing...... methods for enhancing the diagnostic value of medical ultrasound. The project is an industrial Ph.D project co-sponsored by BK Medical ApS., with the commercial goal to improve the image quality of BK Medicals scanners. Currently BK Medical employ a simple conventional delay-and-sum beamformer to generate......-time data acquisition system. The system were implemented using the commercial available 2202 ProFocus BK Medical ultrasound scanner equipped with a research interface and a standard PC. The main feature of the system is the possibility to acquire several seconds of interleaved data, switching between...

  18. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... stomach/ pylorus liver gallbladder spleen pancreas intestines kidneys bladder testicles ovaries uterus Abdominal ultrasound images can be ... and avoid urinating so that his or her bladder is reasonably full when the scan begins. Sedation ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... console containing a computer and electronics, a video display screen and a transducer that is used to ... ultrasound image is immediately visible on a video display screen that looks like a computer or television ...

  20. Hybrid ultrasound imaging techniques (fusion imaging).

    Science.gov (United States)

    Sandulescu, Daniela Larisa; Dumitrescu, Daniela; Rogoveanu, Ion; Saftoiu, Adrian

    2011-01-07

    Visualization of tumor angiogenesis can facilitate non-invasive evaluation of tumor vascular characteristics to supplement the conventional diagnostic imaging goals of depicting tumor location, size, and morphology. Hybrid imaging techniques combine anatomic [ultrasound, computed tomography (CT), and/or magnetic resonance imaging (MRI)] and molecular (single photon emission CT and positron emission tomography) imaging modalities. One example is real-time virtual sonography, which combines ultrasound (grayscale, colour Doppler, or dynamic contrast harmonic imaging) with contrast-enhanced CT/MRI. The benefits of fusion imaging include an increased diagnostic confidence, direct comparison of the lesions using different imaging modalities, more precise monitoring of interventional procedures, and reduced radiation exposure.

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... scan begins. top of page What does the equipment look ... is not a medical facility. Please contact your physician with specific medical ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of blood cells causes a change in pitch of the reflected sound waves (called the Doppler effect). A computer collects ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... various body organs such as the liver or kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler ... and its major ... infants hips in infants spine in infants Ultrasound is also used to: guide procedures such as ...

  4. Rehabilitative ultrasound imaging.

    Science.gov (United States)

    Teyhen, Deydre; Koppenhaver, Shane

    2011-01-01

    Neuromuscular deficits have been linked with chronic musculoskeletal conditions. The use of ultrasound imaging(USI) to aid rehabilitation of neuromusculoskeletal disorders has been called rehabilitative ultrasound imaging (RUSI)and defined as ‘a procedure used by physical therapists to evaluate muscle and related soft tissue morphology and function during exercise and physical tasks. RUSI is used to assist in the application of therapeutic interventions,providing feedback to the patient and physical therapist (Teyhen 2006). Brightness mode (b-mode) USI is the most common form used by physical therapists and will be the focus of this summary. USI can distinguish between healthy adults and those with low back pain (LBP). Those with LBP have decreased muscle thickness, side-to-side asymmetry,and decreased ability to thicken the muscles during a contraction (Teyhen et al 2009). Moreover, when measured by USI, lumbar multifidus muscle asymmetry appears to be predictive of future episode of LBP up to three years later(Hides et al 2001). Finally, USI can distinguish between changes in muscle thickness during common LBP exercises when performed by healthy adults (Teyhen et al 2008) and is preliminarily supported as a biofeedback tool to enhance exercise effectiveness (Henry and Teyhan 2007). CRITERION-RELATED VALIDITY: In a recent systematic review Koppenhaver et al (2009a) concluded that b-mode USI when applied in a rehabilitative setting is a valid tool to measure trunk muscle size and muscle activation during most submaximal contracted states. When comparing muscle thickness obtained by magnetic resonance imaging and USI, researchers have demonstrated substantial agreement(ICC 0.84 to –0.95) with only minimal differences between the modalities (0.03 to 0.21 cm2) (Hides et al 1995, 2006). Although comparisons between electromyography and change in muscle thickness obtained by USI have most often demonstrated a curvilinear relationship (Hodges et al 2003), the ability

  5. Advanced 3-D Ultrasound Imaging

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer

    The main purpose of the PhD project was to develop methods that increase the 3-D ultrasound imaging quality available for the medical personnel in the clinic. Acquiring a 3-D volume gives the medical doctor the freedom to investigate the measured anatomy in any slice desirable after the scan has...... been completed. This allows for precise measurements of organs dimensions and makes the scan more operator independent. Real-time 3-D ultrasound imaging is still not as widespread in use in the clinics as 2-D imaging. A limiting factor has traditionally been the low image quality achievable using...... Field II simulations and measurements with the ultrasound research scanner SARUS and a 3.5MHz 1024 element 2-D transducer array. In all investigations, 3-D synthetic aperture imaging achieved a smaller main-lobe, lower sidelobes, higher contrast, and better signal to noise ratio than parallel...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... various body organs such as the liver or kidneys. There are three types of Doppler ultrasound: Color ... and its major branches liver gallbladder spleen pancreas kidneys bladder uterus , ovaries , and unborn child ( fetus ) in ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... heartbeat. top of page What are some common uses of the procedure? Ultrasound examinations can help to ... the scanner by a cord. Some exams may use different transducers (with different capabilities) during a single ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... procedure like angioplasty . top of page How should I prepare? You should wear comfortable, loose-fitting clothing ... uterus and ovaries. top of page What will I experience during and after the procedure? Ultrasound examinations ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... fluid). In medicine, ultrasound is used to detect changes in appearance, size or contour of organs, tissues, ... the sensitive receiver in the transducer records tiny changes in the sound's pitch and direction. These signature ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements into an array of ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... baby in pregnant women and the brain and hips in infants. It’s also used to help guide ... and parathyroid glands scrotum (testicles) brain in infants hips in infants spine in infants Ultrasound is also ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through the gel into the body. The transducer ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... use of a small transducer (probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through the gel into the body. The transducer collects the sounds ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... diagnose a variety of heart conditions, including valve problems and congestive heart failure, and to assess damage ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Ultrasound examinations can help to diagnose a ... procedure like angioplasty . top of page How should I prepare? You should wear comfortable, loose-fitting clothing ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... because greater amounts of tissue attenuate (weaken) the sound waves as they pass deeper into the body and need to be returned to the transducer for analysis. Ultrasound has difficulty penetrating bone and, therefore, can ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe ... during a single exam. The transducer sends out high-frequency sound waves (that the human ear cannot ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to remove all clothing and ... glasses of water two hours prior to your exam and avoid urinating so that your bladder is ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... help diagnose the causes of pain, swelling and infection in the body’s internal organs and to examine ... help physicians evaluate symptoms such as: pain swelling infection Ultrasound is a useful way of examining many ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and be made aware of food and drink restrictions that may be needed prior to sedation. Once ... minimally invasive procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... is used to help diagnose the causes of pain, swelling and infection in the body’s internal organs ... used to help physicians evaluate symptoms such as: pain swelling infection Ultrasound is a useful way of ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ... a blood vessel. Power Doppler is a newer technique that is more sensitive than color Doppler and ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... arteries and veins in the abdomen, arms, legs, neck and/or brain (in infants and children) or ... used to help physicians evaluate symptoms such as: pain swelling infection Ultrasound is a useful way of ...

  8. Ultrasound in pregnancy (image)

    Science.gov (United States)

    The ultrasound has become a standard procedure used during pregnancy. It can demonstrate fetal growth and can detect increasing ... abnormalities, hydrocephalus, anencephaly, club feet, and other ... does not produce ionizing radiation and is considered ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. top ... make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on the ... probe through the gel into the body. The transducer collects the sounds that bounce back and a ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... pitch) and time it takes for the ultrasound signal to return from the area within the patient ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through ... a single exam. The transducer sends out high-frequency sound waves (that the human ear cannot hear) ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... For others you may be asked to drink up to six glasses of water two hours prior ... ultrasound exams, you will be positioned lying face-up on an examination table that can be tilted ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from the ... within 30 minutes, although more extensive exams may take up to an hour. When the examination is ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... organs and to examine a baby in pregnant women and the brain and hips in infants. It’s ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  16. OSPACS: Ultrasound image management system

    Directory of Open Access Journals (Sweden)

    Bessant Conrad

    2008-06-01

    Full Text Available Abstract Background Ultrasound scanning uses the medical imaging format, DICOM, for electronically storing the images and data associated with a particular scan. Large health care facilities typically use a picture archiving and communication system (PACS for storing and retrieving such images. However, these systems are usually not suitable for managing large collections of anonymized ultrasound images gathered during a clinical screening trial. Results We have developed a system enabling the accurate archiving and management of ultrasound images gathered during a clinical screening trial. It is based upon a Windows application utilizing an open-source DICOM image viewer and a relational database. The system automates the bulk import of DICOM files from removable media by cross-validating the patient information against an external database, anonymizing the data as well as the image, and then storing the contents of the file as a field in a database record. These image records may then be retrieved from the database and presented in a tree-view control so that the user can select particular images for display in a DICOM viewer or export them to external media. Conclusion This system provides error-free automation of ultrasound image archiving and management, suitable for use in a clinical trial. An open-source project has been established to promote continued development of the system.

  17. Ultrasound imaging using coded signals

    DEFF Research Database (Denmark)

    Misaridis, Athanasios

    Modulated (or coded) excitation signals can potentially improve the quality and increase the frame rate in medical ultrasound scanners. The aim of this dissertation is to investigate systematically the applicability of modulated signals in medical ultrasound imaging and to suggest appropriate...... of the excitation signal. Although a gain in signal-to-noise ratio of about 20 dB is theoretically possible for the time-bandwidth product available in ultrasound, it is shown that the effects of transducer weighting and tissue attenuation reduce the maximum gain at 10 dB for robust compression with low sidelobes...... is described. Application of coded excitation in array imaging is evaluated through simulations in Field II. The low degree of the orthogonality among coded signals for ultrasound systems is first discussed, and the effect of mismatched filtering in the cross-correlation properties of the signals is evaluated...

  18. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the ... tissues that do not show up well on x-ray images. Ultrasound provides real-time imaging, making it ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from the ... like sounds that change in pitch as the blood flow is monitored and measured. Once the imaging ... The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  20. High Framerate Imaging of Ultrasound Contrast Agents

    OpenAIRE

    Viti, Jacopo

    2016-01-01

    markdownabstractUltrasound contrast agents (UCAs) consists of a suspension of tiny gas bubbles that is injected into a patient's bloodstream to enhance the visualization of blood in ultrasound images. As UCAs respond differently to ultrasound pulses compared to the surrounding soft tissues and blood, it is possible to employ specialized techniques to identify and isolate UCAs in an ultrasound image. This is commonly referred to as Ultrasound Contrast Imaging. This PhD thesis evaluates several...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... in the abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs such as the liver or kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements into an array of ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and ovaries. top of page What will I experience during and after the procedure? Ultrasound examinations are ... areas. Outside links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo. ...

  3. Carotid Ultrasound Imaging

    Science.gov (United States)

    ... prior to the exam. Bringing books, small toys, music or games can help to distract the child and make the time pass quickly. The ultrasound exam room may have a television. Feel free to ask for your child's favorite channel. No other preparation is required. top of ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then listens for the returning echoes from ... ultrasound , there are no known harmful effects on humans. top ... waves as they pass deeper into the body and need to be returned to the transducer ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... internal organs, including but not limited to the: heart and blood vessels, including the abdominal aorta and its major branches ... damage after a heart attack. Ultrasound of the heart is commonly called an ... and congenital vascular malformations reduced or absent blood flow to various ...

  6. Cardiological Ultrasound Imaging

    NARCIS (Netherlands)

    Thijssen, J.M.; Korte, C.L. de

    2014-01-01

    This review paper is intended for the interested outsider of the field of echocardiography and it presents a short introduction into the numerous ultrasound (US) methods and techniques for anatomical and functional diagnosis of the heart. The basic techniques are generally used for some time

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... so that your bladder is full when the scan begins. top of page What does the equipment look like? Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a transducer that is used ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... medicine, ultrasound is used to detect changes in appearance, size or contour of organs, tissues, and vessels ... either side to improve the quality of the images. A clear water-based gel is applied to the area of the body being studied to help the transducer make secure ...

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen ...

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... an area of tenderness, your child may feel pressure or minor pain from the procedure. If a Doppler ultrasound study is performed, your child may actually hear pulse-like sounds that change in pitch as the blood flow is monitored and measured. Once the imaging ...

  11. Subharmonic aided pressure estimation for monitoring interstitial fluid pressure in tumours--in vitro and in vivo proof of concept.

    Science.gov (United States)

    Halldorsdottir, V G; Dave, J K; Eisenbrey, J R; Machado, P; Zhao, H; Liu, J B; Merton, D A; Forsberg, F

    2014-09-01

    The feasibility of using subharmonic aided pressure estimation (SHAPE) to noninvasively estimate interstitial fluid pressure (IFP) was studied. In vitro, radiofrequency signals, from 0.2 ml/l of Definity (Lantheus Medical Imaging, N Billerica, MA) were acquired within a water-tank with a Sonix RP ultrasound scanner (Analogic Ultrasound, Richmond, BC, Canada; fT/R=6.7/3.35 MHz and fT/R=10/5 MHz) and the subharmonic amplitudes of the signals were compared over 0-50 mmHg. In vivo, five swine with naturally occurring melanomas were studied. Subharmonic signals were acquired from tumours and surrounding tissue during infusion of Definity and compared to needle-based pressure measurements. Both in vitro and in vivo, an inverse linear relationship between hydrostatic pressure and subharmonic amplitude was observed with r(2)=0.63-0.95; p<0.05, maximum amplitude drop 11.36 dB at 10 MHz and -8 dB, and r(2) as high as 0.97; p<0.02 (10 MHz and -4/-8 dB most promising), respectively, indicating that SHAPE may be useful in monitoring IFP. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of North America ( ...

  13. Non-linear Ultrasound Imaging

    DEFF Research Database (Denmark)

    Du, Yigang

    without iteration steps. The ASA is implemented in combination with Field II and extended to simulate the pulsed ultrasound fields. The simulated results from a linear array transducer are made by the ASA based on Field II, and by a released non-linear simulation program- Abersim, respectively....... The calculation speed of the ASA is increased approximately by a factor of 140. For the second harmonic point spread function the error of the full width is 1.5% at -6 dB and 6.4% at -12 dB compared to Abersim. To further investigate the linear and non-linear ultrasound fields, hydrophone measurements.......3% relative to the measurement from a 1 inch diameter transducer. A preliminary study for harmonic imaging using synthetic aperture sequential beamforming (SASB) has been demonstrated. A wire phantom underwater measurement is made by an experimental synthetic aperture real-time ultrasound scanner (SARUS...

  14. Synthetic Aperture Imaging in Medical Ultrasound

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Gammelmark, Kim; Pedersen, Morten

    2004-01-01

    Synthetic Aperture (SA) ultrasound imaging is a relatively new and unexploited imaging technique. The images are perfectly focused both in transmit and receive, and have a better resolution and higher dynamic range than conventional ultrasound images. The blood flow can be estimated from SA image...

  15. Recursive Ultrasound Imaging

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Gammelmark, Kim; Jensen, Jørgen Arendt

    1999-01-01

    This paper presents a new imaging method, applicable for both 2D and 3D imaging. It is based on Synthetic Transmit Aperture Focusing, but unlike previous approaches a new frame is created after every pulse emission. The elements from a linear transducer array emit pulses one after another. The sa...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... to sample cells from an abnormal area for laboratory testing. image the breasts and guide biopsy of ... by Please note RadiologyInfo.org is not a medical facility. Please contact your physician with specific medical ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... display screen that looks like a computer or television monitor. The image is created based on the ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... be turned to either side to improve the quality of the images. After you are positioned on ... about this beforehand and be made aware of food and drink restrictions that may be needed prior ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... In most cases, barium exams, CT scanning , and MRI are the methods of choice in such a ... or certain joints, other imaging modalities such as MRI are typically used. top of page This page ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... display screen that looks like a computer or television monitor. The image is created based on the ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  1. General Ultrasound Imaging

    Science.gov (United States)

    ... display screen that looks like a computer or television monitor. The image is created based on the ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... by taking our brief survey: Survey Do you have a personal story about radiology? Share your patient ... caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child- ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... are used to sample cells from an abnormal area for laboratory testing. image the breasts and guide ... organs greater than normal blood flow to different areas, which is sometimes seen in infections With knowledge ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank ... View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... The image is created based on the amplitude (loudness), frequency (pitch) and time it takes for the ... are typically used. top of page This page was reviewed on May 30, 2016 Send us your ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... images and send a signed report to your primary care physician, or to the physician or other healthcare provider who requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... screen that looks like a computer or television monitor. The image is created based on the amplitude ( ... turn creates a real-time picture on the monitor. One or more frames of the moving pictures ...

  10. Subharmonic microbubble emissions for noninvasively tracking right ventricular pressures.

    Science.gov (United States)

    Dave, Jaydev K; Halldorsdottir, Valgerdur G; Eisenbrey, John R; Raichlen, Joel S; Liu, Ji-Bin; McDonald, Maureen E; Dickie, Kris; Wang, Shumin; Leung, Corina; Forsberg, Flemming

    2012-07-01

    Right heart catheterization is often required to monitor intra-cardiac pressures in a number of disease states. Ultrasound contrast agents can produce pressure modulated subharmonic emissions that may be used to estimate right ventricular (RV) pressures. A technique based on subharmonic acoustic emissions from ultrasound contrast agents to track RV pressures noninvasively has been developed and its clinical potential evaluated. The subharmonic signals were obtained from the aorta, RV, and right atrium (RA) of five anesthetized closed-chest mongrel dogs using a SonixRP ultrasound scanner and PA4-2 phased array. Simultaneous pressure measurements were obtained using a 5-French solid state micromanometer tipped catheter. Initially, aortic subharmonic signals and systemic blood pressures were used to obtain a calibration factor in units of millimeters of mercury per decibel. This factor was combined with RA pressures (that can be obtained noninvasively) and the acoustic data from the RV to obtain RV pressure values. The individual calibration factors ranged from -2.0 to -4.0 mmHg/dB. The subharmonic signals tracked transient changes in the RV pressures within an error of 0.6 mmHg. Relative to the catheter pressures, the mean errors in estimating RV peak systolic and minimum diastolic pressures, and RV relaxation [isovolumic negative derivative of change in pressure over time (-dP/dt)] by use of the subharmonic signals, were -2.3 mmHg, -0.8 mmHg, and 2.9 mmHg/s, respectively. Overall, acoustic estimates of RV peak systolic and minimum diastolic pressures and RV relaxation were within 3.4 mmHg, 1.8 mmHg, and 5.9 mmHg/s, respectively, of the measured pressures. This pilot study demonstrates that subharmonic emissions from ultrasound contrast agents have the potential to noninvasively track in vivo RV pressures with errors below 3.5 mmHg.

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... located within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ...

  12. Ultrasound molecular imaging: Moving toward clinical translation

    Energy Technology Data Exchange (ETDEWEB)

    Abou-Elkacem, Lotfi; Bachawal, Sunitha V.; Willmann, Jürgen K., E-mail: willmann@stanford.edu

    2015-09-15

    Highlights: • Ultrasound molecular imaging is a highly sensitive modality. • A clinical grade ultrasound contrast agent has entered first in human clinical trials. • Several new potential future clinical applications of ultrasound molecular imaging are being explored. - Abstract: Ultrasound is a widely available, cost-effective, real-time, non-invasive and safe imaging modality widely used in the clinic for anatomical and functional imaging. With the introduction of novel molecularly-targeted ultrasound contrast agents, another dimension of ultrasound has become a reality: diagnosing and monitoring pathological processes at the molecular level. Most commonly used ultrasound molecular imaging contrast agents are micron sized, gas-containing microbubbles functionalized to recognize and attach to molecules expressed on inflamed or angiogenic vascular endothelial cells. There are several potential clinical applications currently being explored including earlier detection, molecular profiling, and monitoring of cancer, as well as visualization of ischemic memory in transient myocardial ischemia, monitoring of disease activity in inflammatory bowel disease, and assessment of arteriosclerosis. Recently, a first clinical grade ultrasound contrast agent (BR55), targeted at a molecule expressed in neoangiogenesis (vascular endothelial growth factor receptor type 2; VEGFR2) has been introduced and safety and feasibility of VEGFR2-targeted ultrasound imaging is being explored in first inhuman clinical trials in various cancer types. This review describes the design of ultrasound molecular imaging contrast agents, imaging techniques, and potential future clinical applications of ultrasound molecular imaging.

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological Society of North America, Inc. ( ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... be turned to either side to improve the quality of the images. After you are positioned on the examination table, the radiologist (a physician specifically trained to supervise and interpret radiology examinations) or sonographer will apply a warm water-based gel to the area of the body ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary so that any change in a known abnormality can be monitored over ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... medical test that helps physicians diagnose and treat medical ... is a small hand-held device that resembles a microphone, attached to the scanner ...

  17. Ultrasound technologies for biomaterials fabrication and imaging.

    Science.gov (United States)

    Dalecki, Diane; Hocking, Denise C

    2015-03-01

    Ultrasound is emerging as a powerful tool for developing biomaterials for regenerative medicine. Ultrasound technologies are finding wide-ranging, innovative applications for controlling the fabrication of bioengineered scaffolds, as well as for imaging and quantitatively monitoring the properties of engineered constructs both during fabrication processes and post-implantation. This review provides an overview of the biomedical applications of ultrasound for imaging and therapy, a tutorial of the physical mechanisms through which ultrasound can interact with biomaterials, and examples of how ultrasound technologies are being developed and applied for biomaterials fabrication processes, non-invasive imaging, and quantitative characterization of bioengineered scaffolds in vitro and in vivo.

  18. High Framerate Imaging of Ultrasound Contrast Agents

    NARCIS (Netherlands)

    J. Viti (Jacopo)

    2016-01-01

    markdownabstractUltrasound contrast agents (UCAs) consists of a suspension of tiny gas bubbles that is injected into a patient's bloodstream to enhance the visualization of blood in ultrasound images. As UCAs respond differently to ultrasound pulses compared to the surrounding soft tissues and

  19. Medical Imaging with Ultrasound: Some Basic Physics.

    Science.gov (United States)

    Gosling, R.

    1989-01-01

    Discussed are medical applications of ultrasound. The physics of the wave nature of ultrasound including its propagation and production, return by the body, spatial and contrast resolution, attenuation, image formation using pulsed echo ultrasound techniques, measurement of velocity and duplex scanning are described. (YP)

  20. Subharmonic aided pressure estimation for monitoring interstitial fluid pressure in tumours -in vitro and in vivo proof of concept

    Science.gov (United States)

    Halldorsdottir, V G; Dave, J K; Eisenbrey, J R; Machado, P; Zhao, H; Liu, J B; Merton, D A; Forsberg, F

    2014-01-01

    The feasibility of using subharmonic aided pressure estimation (SHAPE) to noninvasively estimate interstitial fluid pressure (IFP) was studied. In vitro, radiofrequency signals, from 0.2 ml/l of Definity (Lantheus Medical Imaging, N Billerica, MA) were acquired within a water-tank with a Sonix RP ultrasound scanner (Ultrasonix, Richmond, BC, Canada; fT/R=6.7/3.35 MHz and fT/R =10/5 MHz) and the subharmonic amplitudes of the signals were compared over 0–50 mmHg. In vivo, five swine with naturally occurring melanomas were studied. Subharmonic signals were acquired from tumours and surrounding tissue during infusion of Definity and compared to needle-based pressure measurements. Both in vitro and in vivo, an inverse linear relationship between hydrostatic pressure and subharmonic amplitude was observed with r2=0.63–0.95; p<0.05, maximum amplitude drop 11.36 dB at 10 MHz and −8 dB, and r2 as high as 0.97; p<0.02 (10 MHz and −4/−8 dB most promising), respectively, indicating that SHAPE may be useful in monitoring IFP. PMID:24856899

  1. Despeckling of Medical Ultrasound Images

    Science.gov (United States)

    Michailovich, Oleg V.; Tannenbaum, Allen

    2013-01-01

    Speckle noise is an inherent property of medical ultrasound imaging, and it generally tends to reduce the image resolution and contrast, thereby reducing the diagnostic value of this imaging modality. As a result, speckle noise reduction is an important prerequisite, whenever ultrasound imaging is used for tissue characterization. Among the many methods that have been proposed to perform this task, there exists a class of approaches that use a multiplicative model of speckled image formation and take advantage of the logarithmical transformation in order to convert multiplicative speckle noise into additive noise. The common assumption made in a dominant number of such studies is that the samples of the additive noise are mutually uncorrelated and obey a Gaussian distribution. The present study shows conceptually and experimentally that this assumption is oversimplified and unnatural. Moreover, it may lead to inadequate performance of the speckle reduction methods. The study introduces a simple preprocessing procedure, which modifies the acquired radio-frequency images (without affecting the anatomical information they contain), so that the noise in the log-transformation domain becomes very close in its behavior to a white Gaussian noise. As a result, the preprocessing allows filtering methods based on assuming the noise to be white and Gaussian, to perform in nearly optimal conditions. The study evaluates performances of three different, nonlinear filters—wavelet denoising, total variation filtering, and anisotropic diffusion—and demonstrates that, in all these cases, the proposed preprocessing significantly improves the quality of resultant images. Our numerical tests include a series of computer-simulated and in vivo experiments. PMID:16471433

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... blood vessels located within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a ...

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... child's abdominal ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... located within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound ... pain from the procedure. If a Doppler ultrasound study is performed, your child may actually hear pulse- ...

  5. Handheld ultrasound array imaging device

    Science.gov (United States)

    Hwang, Juin-Jet; Quistgaard, Jens

    1999-06-01

    A handheld ultrasound imaging device, one that weighs less than five pounds, has been developed for diagnosing trauma in the combat battlefield as well as a variety of commercial mobile diagnostic applications. This handheld device consists of four component ASICs, each is designed using the state of the art microelectronics technologies. These ASICs are integrated with a convex array transducer to allow high quality imaging of soft tissues and blood flow in real time. The device is designed to be battery driven or ac powered with built-in image storage and cineloop playback capability. Design methodologies of a handheld device are fundamentally different to those of a cart-based system. As system architecture, signal and image processing algorithm as well as image control circuit and software in this device is deigned suitably for large-scale integration, the image performance of this device is designed to be adequate to the intent applications. To elongate the battery life, low power design rules and power management circuits are incorporated in the design of each component ASIC. The performance of the prototype device is currently being evaluated for various applications such as a primary image screening tool, fetal imaging in Obstetrics, foreign object detection and wound assessment for emergency care, etc.

  6. Noninvasive LV pressure estimation using subharmonic emissions from microbubbles.

    Science.gov (United States)

    Dave, Jaydev K; Halldorsdottir, Valgerdur G; Eisenbrey, John R; Raichlen, Joel S; Liu, Ji-Bin; McDonald, Maureen E; Dickie, Kris; Wang, Shumin; Leung, Corina; Forsberg, Flemming

    2012-01-01

    To develop a new noninvasive approach to quantify left ventricular (LV) pressures using subharmonic emissions from microbubbles, an ultrasound scanner was used in pulse inversion grayscale mode; unprocessed radiofrequency data were obtained with pulsed wave Doppler from the aorta and/or LV during Sonazoid infusion. Subharmonic data (in dB) were extracted and processed. Calibration factor (mm Hg/dB) from the aortic pressure was used to estimate LV pressures. Errors ranged from 0.19 to 2.50 mm Hg when estimating pressures using the aortic calibration factor, and were higher (0.64 to 8.98 mm Hg) using a mean aortic calibration factor. Subharmonic emissions from ultrasound contrast agents have the potential to noninvasively monitor LV pressures. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Breast ultrasound image segmentation: a survey.

    Science.gov (United States)

    Huang, Qinghua; Luo, Yaozhong; Zhang, Qiangzhi

    2017-03-01

    Breast cancer is the most common form of cancer among women worldwide. Ultrasound imaging is one of the most frequently used diagnostic tools to detect and classify abnormalities of the breast. Recently, computer-aided diagnosis (CAD) systems using ultrasound images have been developed to help radiologists to increase diagnosis accuracy. However, accurate ultrasound image segmentation remains a challenging problem due to various ultrasound artifacts. In this paper, we investigate approaches developed for breast ultrasound (BUS) image segmentation. In this paper, we reviewed the literature on the segmentation of BUS images according to the techniques adopted, especially over the past 10 years. By dividing into seven classes (i.e., thresholding-based, clustering-based, watershed-based, graph-based, active contour model, Markov random field and neural network), we have introduced corresponding techniques and representative papers accordingly. We have summarized and compared many techniques on BUS image segmentation and found that all these techniques have their own pros and cons. However, BUS image segmentation is still an open and challenging problem due to various ultrasound artifacts introduced in the process of imaging, including high speckle noise, low contrast, blurry boundaries, low signal-to-noise ratio and intensity inhomogeneity CONCLUSIONS: To the best of our knowledge, this is the first comprehensive review of the approaches developed for segmentation of BUS images. With most techniques involved, this paper will be useful and helpful for researchers working on segmentation of ultrasound images, and for BUS CAD system developers.

  8. Ultrasound Molecular Imaging: Moving Towards Clinical Translation

    Science.gov (United States)

    Abou-Elkacem, Lotfi; Bachawal, Sunitha V.; Willmann, Jürgen K.

    2015-01-01

    Ultrasound is a widely available, cost-effective, real-time, non-invasive and safe imaging modality widely used in the clinic for anatomical and functional imaging. With the introduction of novel molecularly-targeted ultrasound contrast agents, another dimension of ultrasound has become a reality: diagnosing and monitoring pathological processes at the molecular level. Most commonly used ultrasound molecular imaging contrast agents are micron sized, gas-containing microbubbles functionalized to recognize and attach to molecules expressed on inflamed or angiogenic vascular endothelial cells. There are several potential clinical applications currently being explored including earlier detection, molecular profiling, and monitoring of cancer, as well as visualization of ischemic memory in transient myocardial ischemia, monitoring of disease activity in inflammatory bowel disease, and assessment of arteriosclerosis. Recently, a first clinical grade ultrasound contrast agent (BR55), targeted at a molecule expressed in neoangiogenesis (vascular endothelial growth factor receptor type 2; VEGFR2) has been introduced and safety and feasibility of VEGFR2-targeted ultrasound imaging is being explored in first inhuman clinical trials in various cancer types. This review describes the design of ultrasound molecular imaging contrast agents, imaging techniques, and potential future clinical applications of ultrasound molecular imaging. PMID:25851932

  9. Ultrasound molecular imaging: Moving toward clinical translation.

    Science.gov (United States)

    Abou-Elkacem, Lotfi; Bachawal, Sunitha V; Willmann, Jürgen K

    2015-09-01

    Ultrasound is a widely available, cost-effective, real-time, non-invasive and safe imaging modality widely used in the clinic for anatomical and functional imaging. With the introduction of novel molecularly-targeted ultrasound contrast agents, another dimension of ultrasound has become a reality: diagnosing and monitoring pathological processes at the molecular level. Most commonly used ultrasound molecular imaging contrast agents are micron sized, gas-containing microbubbles functionalized to recognize and attach to molecules expressed on inflamed or angiogenic vascular endothelial cells. There are several potential clinical applications currently being explored including earlier detection, molecular profiling, and monitoring of cancer, as well as visualization of ischemic memory in transient myocardial ischemia, monitoring of disease activity in inflammatory bowel disease, and assessment of arteriosclerosis. Recently, a first clinical grade ultrasound contrast agent (BR55), targeted at a molecule expressed in neoangiogenesis (vascular endothelial growth factor receptor type 2; VEGFR2) has been introduced and safety and feasibility of VEGFR2-targeted ultrasound imaging is being explored in first inhuman clinical trials in various cancer types. This review describes the design of ultrasound molecular imaging contrast agents, imaging techniques, and potential future clinical applications of ultrasound molecular imaging. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... minutes. top of page What will my child experience during and after the procedure? Ultrasound examinations are ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... used to extract sample cells from an abnormal area for laboratory testing. Ultrasound may also be used ... organs greater than normal blood flow to different areas, which is sometimes seen in infections Doppler ultrasound ...

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... be guided by ultrasound, are used to sample cells from organs for laboratory testing help detect the ... in which needles are used to extract sample cells from an abnormal area for laboratory testing. Ultrasound ...

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Your child should wear loose, comfortable clothing and may be asked to wear a gown. What is ... within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound examination. ...

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... How should we prepare for an abdominal ultrasound exam? Your child should be dressed in comfortable, loose-fitting clothing for an ultrasound exam. Other preparation depends on the type of examination. ...

  15. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... cord and hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known ...

  16. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... records tiny changes in the sound's pitch and direction. These signature waves are instantly measured and displayed ... ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as they move ...

  17. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... extremely safe and does not use any ionizing radiation. Ultrasound scanning gives a clear picture of soft ...

  18. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... may also be saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of ... following text box: Comment: E-mail: Area code: Phone no: Thank you! Do you have a personal ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... may also be saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of ... care physician, or to the physician or other healthcare provider who requested the exam. Usually, the referring ...

  20. Ultrasound Imaging of Cystic Nephroma

    Directory of Open Access Journals (Sweden)

    Federico Greco

    2017-07-01

    Full Text Available Cystic nephroma is a rare, benign multicystic lesion of the kidney. This tumor occurs both in children and in adults. In children, it is highly prevalent in males; in adults, it is more frequent in women. The term “cystic nephroma” represents two apparently different entities: pediatric cystic nephroma, a benign form thought to originate from metanephric tissue, and adult cystic nephroma, considered as a lesion of mixed epithelial stromal tumor. The clinical presentation may be a palpable mass or nonspecific symptoms such as abdominal pain, hematuria, and urinary tract infections. In this review, we summarize the ultrasound imaging features of cystic nephroma and describe the characteristics of the most common renal cystic lesions and the differential diagnosis of cystic nephroma with other renal cystic lesions.

  1. Ultrasound

    Science.gov (United States)

    Ultrasound is a type of imaging. It uses high-frequency sound waves to look at organs and ... liver, and other organs. During pregnancy, doctors use ultrasound to view the fetus. Unlike x-rays, ultrasound ...

  2. Linear description of ultrasound imaging systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    These notes have been prepared for the international summer school on advanced ultrasound imaging sponsored by The Danish Research Academy. The notes should be read in conjunction with the notes prepared by Anderson and Trahey1. The intended audience is Ph.D. students working in medical ultrasound...

  3. Subharmonic emissions from microbubbles: effect of the driving pulse shape.

    Science.gov (United States)

    Biagi, Elena; Breschi, Luca; Vannacci, Enrico; Masotti, Leonardo

    2006-11-01

    The aims of this work are to investigate the response of the ultrasonic contrast agents (UCA) insonified by different arbitrary-shaped pulses at different acoustic pressures and concentration of the contrast agent focusing on subharmonic emission. A transmission setup was developed in order to insonify the contrast agent contained in a measurement chamber. The transmitted ultrasonic signals were generated by an arbitrary wave generator connected to a linear power amplifier able to drive a single-element transducer. The transmitted ultrasonic pulses that passed through the contrast agent-filled chamber were received by a second transducer or a hydrophone aligned with the first one. The radio frequency (RF) signals were acquired by fast echographic multiparameters multi-image novel apparatus (FEMMINA), which is an echographic platform able to acquire ultrasonic signals in a real-time modality. Three sets of ultrasonic signals were devised in order to evaluate subharmonic response of the contrast agent respect with sinusoidal burst signals used as reference pulses. A decreasing up to 30 dB in subharmonic response was detected for a Gaussian-shaped pulse; differences in subharmonic emission up to 21 dB were detected for a composite pulse (two-tone burst) for different acoustic pressures and concentrations. Results from this experimentation demonstrated that the transmitted pulse shape strongly affects subharmonic emission in spite of a second harmonic one. In particular, the smoothness of the initial portion of the shaped pulses can inhibit subharmonic generation from the contrast agents respect with a reference sinusoidal burst signal. It also was shown that subharmonic generation is influenced by the amplitude and the concentration of the contrast agent for each set of the shaped pulses. Subharmonic emissions that derive from a nonlinear mechanism involving nonlinear coupling among different oscillation modes are strongly affected by the shape of the ultrasonic

  4. Virtual ultrasound sources in high-resolution ultrasound imaging

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Jensen, Jørgen Arendt

    2002-01-01

    beamforming procedure for 3D ultrasound imaging. The position of the virtual source, and the created waveform are investigated with simulation, and with pulse-echo measurements. There is good agreement between the estimated wavefront and the theoretically tted one. Several examples of the use of virtual...

  5. Synthetic aperture tissue and flow ultrasound imaging

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav

    This Ph.D. project was carried out at the Center for Fast Ultrasound Imaging, Technical University of Denmark. The goal was to improve existing imaging techniques in order to make them suitable for real-time three-dimensional ultrasound scanning. This dissertation focuses on the synthetic aperture...... imaging applied to medical ultrasound. It is divided into two major parts: tissue and blood flow imaging. Tissue imaging using synthetic aperture algorithms has been investigated for about two decades, but has not been implemented in medical scanners yet. Among the other reasons, the conventional scanning...... and beamformation methods are adequate for the imaging modalities in clinical use - the B-mode imaging of tissue structures, and the color mapping of blood flow. The acquisition time, however, is too long, and these methods fail to perform real-time three-dimensional scans. The synthetic transmit aperture...

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of blood cells causes a change in pitch of the reflected sound waves (called the Doppler effect). A computer collects ...

  7. Deconvolution of in vivo ultrasound images

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1990-01-01

    In an ultrasound image, the influence of the pulse and attenuation should be removed from the picture in order to display a more consistent and uniform image. The author describes an algorithm to remove the influence of the attenuated pulse on the image. The algorithm takes into account the varying...

  8. SHM of single lap adhesive joints using subharmonic frequencies

    Science.gov (United States)

    Ginzburg, D.; Ciampa, F.; Scarselli, G.; Meo, M.

    2017-10-01

    The increased usage of adhesive bonding as a joining method in modern aerospace components has led to developing reliable ultrasonic health monitoring systems for detection of regions of poor adhesion. Nonlinear acousto-ultrasonic techniques based on higher harmonics and subharmonic frequencies have shown to be sensitive to the detection of micro-voids and disbonds. Nonlinear resonance properties of disbonds generate various nonlinear phenomena such as self-modulation, subharmonics, hysteresis and so on. By exploiting the local natures of these phenomena, this paper demonstrates the use of subharmonics for detection and imaging of flaws in bonded structures. To optimise the experimental testing a two-dimensional analytical model and a three-dimensional finite element analysis simulation were developed for understanding the generation of nonlinear elastic effects with emphasis on subharmonic frequency components. The proposed analytical model qualitatively described the generation of subharmonics but also higher harmonics due to the nonlinear intermodulation of the driving and resonance frequencies associated with the disbonded region. The numerical model was developed by modifying the user defined cohesive element formulation with a bi-linear traction-displacement relationship in order to simulate the interaction of elastic waves with the structural disbond. Whilst the analytical model supported the selection of the driving frequency, the numerical one successfully predicted the generation of subharmonic frequencies originating in the disbonded area. Experimental tests were conducted on a disbonded single lap joint structure using surface-bonded piezoelectric transducers and a laser-Doppler vibrometer, and allowed to validate the analytical and numerical results. It was clearly demonstrated that the nonlinear resonance effects in the form of subharmonics could be used to discriminate reliably regions of poor adhesion in bonded structures. This work can lead to new

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... fluid). In medicine, ultrasound is used to detect changes in appearance, size or contour of organs, tissues, ... the sensitive receiver in the transducer records tiny changes in the sound's pitch and direction. These signature ...

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... within 30 minutes. top of page What will my child experience during and after the procedure? Ultrasound ... feedback Did you find the information you were looking for? Yes No Please type your comment or ...

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... scans, your doctor may ask you to withhold food and drink for several hours before your child's ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... are used to sample cells from organs for laboratory testing help detect the presence and cause of ... extract sample cells from an abnormal area for laboratory testing. Ultrasound may also be used to guide ...

  15. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through the gel into the body. The transducer ...

  16. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  17. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... any ionizing radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up ... and/or your insurance provider to get a better understanding of the possible charges you will incur. ...

  18. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... use of a small transducer (probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through the gel into the body. The transducer collects the sounds ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound exams, you will be positioned lying face-up on an examination table that can be tilted ... you at the conclusion of your examination. Follow-up examinations may be necessary. Your doctor will explain ...

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe ... during a single exam. The transducer sends out high-frequency sound waves (that the human ear cannot ...

  1. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... the exam. Your child should wear loose, comfortable clothing and may be asked to wear a gown. ... child should be dressed in comfortable, loose-fitting clothing for an ultrasound exam. Other preparation depends on ...

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... for evaluating the brain, spinal cord and hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known harmful effects on humans. top of ...

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... for laboratory testing help detect the presence and cause of an apparent enlarged abdominal organ identify the ... of abnormal fluid in the abdomen help determine causes of vomiting in young infants Because ultrasound provides ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... used to sample cells from organs for laboratory testing help detect the presence and cause of an ... sample cells from an abnormal area for laboratory testing. Ultrasound may also be used to guide the ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... blood flow (such as clots) narrowing of vessels tumors and congenital vascular malformations reduced or absent blood ... vessels or to detect abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends ...

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. top ... make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  7. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on the ... probe through the gel into the body. The transducer collects the sounds that bounce back and a ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through ... a single exam. The transducer sends out high-frequency sound waves (that the human ear cannot hear) ...

  9. Effect of Pulse Shaping on Subharmonic Aided Pressure Estimation In Vitro and In Vivo.

    Science.gov (United States)

    Gupta, Ipshita; Eisenbrey, John; Stanczak, Maria; Sridharan, Anush; Dave, Jaydev K; Liu, Ji-Bin; Hazard, Christopher; Wang, Xinghua; Wang, Ping; Li, Huiwen; Wallace, Kirk; Forsberg, Flemming

    2017-01-01

    Subharmonic imaging (SHI) is a technique that uses the nonlinear oscillations of microbubbles when exposed to ultrasound at high pressures transmitting at the fundamental frequency ie, fo and receiving at half the transmit frequency (ie, fo /2). Subharmonic aided pressure estimation (SHAPE) is based on the inverse relationship between the subharmonic amplitude of the microbubbles and the ambient pressure change. Eight waveforms with different envelopes were optimized with respect to acoustic power at which the SHAPE study is most sensitive. The study was run with four input transmit cycles, first in vitro and then in vivo in three canines to select the waveform that achieved the best sensitivity for detecting changes in portal pressures using SHAPE. A Logiq 9 scanner with a 4C curvi-linear array was used to acquire 2.5 MHz radio-frequency data. Scanning was performed in dual imaging mode with B-mode imaging at 4 MHz and a SHI contrast mode transmitting at 2.5 MHz and receiving at 1.25 MHz. Sonazoid, which is a lipid stabilized gas filled bubble of perfluorobutane, was used as the contrast agent in this study. A linear decrease in subharmonic amplitude with increased pressure was observed for all waveforms (r from -0.77 to -0.93; P < .001) in vitro. There was a significantly higher correlation of the SHAPE gradient with changing pressures for the broadband pulses as compared to the narrowband pulses in both in vitro and in vivo results. The highest correlation was achieved with a Gaussian windowed binomial filtered square wave with an r-value of -0.95. One of the three canines was eliminated for technical reasons, while the other two produced very similar results to those obtained in vitro (r from -0.72 to -0.98; P <.01). The most consistent in vivo results were achieved with the Gaussian windowed binomial filtered square wave (r = -0.95 and -0.96). Using this waveform is an improvement to the existing SHAPE technique (where a square wave was used) and

  10. Nonlinear ultrasound imaging of nanoscale acoustic biomolecules

    Science.gov (United States)

    Maresca, David; Lakshmanan, Anupama; Lee-Gosselin, Audrey; Melis, Johan M.; Ni, Yu-Li; Bourdeau, Raymond W.; Kochmann, Dennis M.; Shapiro, Mikhail G.

    2017-02-01

    Ultrasound imaging is widely used to probe the mechanical structure of tissues and visualize blood flow. However, the ability of ultrasound to observe specific molecular and cellular signals is limited. Recently, a unique class of gas-filled protein nanostructures called gas vesicles (GVs) was introduced as nanoscale (˜250 nm) contrast agents for ultrasound, accompanied by the possibilities of genetic engineering, imaging of targets outside the vasculature and monitoring of cellular signals such as gene expression. These possibilities would be aided by methods to discriminate GV-generated ultrasound signals from anatomical background. Here, we show that the nonlinear response of engineered GVs to acoustic pressure enables selective imaging of these nanostructures using a tailored amplitude modulation strategy. Finite element modeling predicted a strongly nonlinear mechanical deformation and acoustic response to ultrasound in engineered GVs. This response was confirmed with ultrasound measurements in the range of 10 to 25 MHz. An amplitude modulation pulse sequence based on this nonlinear response allows engineered GVs to be distinguished from linear scatterers and other GV types with a contrast ratio greater than 11.5 dB. We demonstrate the effectiveness of this nonlinear imaging strategy in vitro, in cellulo, and in vivo.

  11. Spectral clustering algorithms for ultrasound image segmentation.

    Science.gov (United States)

    Archip, Neculai; Rohling, Robert; Cooperberg, Peter; Tahmasebpour, Hamid; Warfield, Simon K

    2005-01-01

    Image segmentation algorithms derived from spectral clustering analysis rely on the eigenvectors of the Laplacian of a weighted graph obtained from the image. The NCut criterion was previously used for image segmentation in supervised manner. We derive a new strategy for unsupervised image segmentation. This article describes an initial investigation to determine the suitability of such segmentation techniques for ultrasound images. The extension of the NCut technique to the unsupervised clustering is first described. The novel segmentation algorithm is then performed on simulated ultrasound images. Tests are also performed on abdominal and fetal images with the segmentation results compared to manual segmentation. Comparisons with the classical NCut algorithm are also presented. Finally, segmentation results on other types of medical images are shown.

  12. Simulation of ultrasound backscatter images from fish

    DEFF Research Database (Denmark)

    Pham, An Hoai; Stage, Bjarne; Hemmsen, Martin Christian

    2011-01-01

    The objective of this work is to investigate ultrasound (US) backscatter in the MHz range from fis to develop a realistic and reliable simulation model. The long term objective of the work is to develop the needed signal processing for fis species differentiation using US. In in-vitro experiments...... images reproduce most of the important characteristics of the measured US image....

  13. Ultrasound image guidance of cardiac interventions

    Science.gov (United States)

    Peters, Terry M.; Pace, Danielle F.; Lang, Pencilla; Guiraudon, Gérard M.; Jones, Douglas L.; Linte, Cristian A.

    2011-03-01

    Surgical procedures often have the unfortunate side-effect of causing the patient significant trauma while accessing the target site. Indeed, in some cases the trauma inflicted on the patient during access to the target greatly exceeds that caused by performing the therapy. Heart disease has traditionally been treated surgically using open chest techniques with the patient being placed "on pump" - i.e. their circulation being maintained by a cardio-pulmonary bypass or "heart-lung" machine. Recently, techniques have been developed for performing minimally invasive interventions on the heart, obviating the formerly invasive procedures. These new approaches rely on pre-operative images, combined with real-time images acquired during the procedure. Our approach is to register intra-operative images to the patient, and use a navigation system that combines intra-operative ultrasound with virtual models of instrumentation that has been introduced into the chamber through the heart wall. This paper illustrates the problems associated with traditional ultrasound guidance, and reviews the state of the art in real-time 3D cardiac ultrasound technology. In addition, it discusses the implementation of an image-guided intervention platform that integrates real-time ultrasound with a virtual reality environment, bringing together the pre-operative anatomy derived from MRI or CT, representations of tracked instrumentation inside the heart chamber, and the intra-operatively acquired ultrasound images.

  14. Ultrasound imaging and contrast agents: a safe alternative to MRI?

    NARCIS (Netherlands)

    Wink, Margot H.; Wijkstra, Hessel; de La Rosette, Jean J. M. C. H.; Grimbergen, Cornelis A.

    2006-01-01

    Microbubble contrast media are used to enhance ultrasound images. Because ultrasound is a real-time investigation, contrast-enhanced ultrasound offers possibilities for perfusion imaging. This review is conducted to evaluate the safety of contrast-enhanced ultrasound and its possible role in medical

  15. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... your child’s abdomen. Ultrasound does not use ionizing radiation, has no known harmful effects, and is particularly valuable for evaluating abdominal, pelvic or scrotal pain in children. Preparation will depend on the type of examination. Ask your doctor if there are ...

  16. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... children. It is also valuable for evaluating the brain, spinal cord and hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  17. Vascular ultrasound for atherosclerosis imaging

    NARCIS (Netherlands)

    C.L. de Korte (Chris); H.H.G. Hansen (Hendrik); A.F.W. van der Steen (Ton)

    2011-01-01

    textabstractCardiovascular disease is a leading cause of death in the Western world. Therefore, detection and quantification of atherosclerotic disease is of paramount importance to monitor treatment and possible prevention of acute events. Vascular ultrasound is an excellent technique to assess the

  18. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... minutes. top of page What will my child experience during and after the procedure? Ultrasound examinations are ... areas. Outside links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo. ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... effects, and is particularly valuable for evaluating abdominal, pelvic or scrotal pain in children. Preparation will depend on the type ... aspiration. Ultrasound is particularly valuable for evaluating abdominal, pelvic or scrotal pain in young children. It is also valuable for ...

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then listens for the returning echoes from ... ultrasound , there are no known harmful effects on humans. top ... waves as they pass deeper into the body and need to be returned to the transducer ...

  1. Investigating the efficacy of subharmonic aided pressure estimation for portal vein pressures and portal hypertension monitoring.

    Science.gov (United States)

    Dave, Jaydev K; Halldorsdottir, Valgerdur G; Eisenbrey, John R; Merton, Daniel A; Liu, Ji-Bin; Zhou, Jian-Hua; Wang, Hsin-Kai; Park, Suhyun; Dianis, Scott; Chalek, Carl L; Lin, Feng; Thomenius, Kai E; Brown, Daniel B; Forsberg, Flemming

    2012-10-01

    The efficacy of using subharmonic emissions from Sonazoid microbubbles (GE Healthcare, Oslo, Norway) to track portal vein pressures and pressure changes was investigated in 14 canines using either slow- or high-flow models of portal hypertension (PH). A modified Logiq 9 scanner (GE Healthcare, Milwaukee, WI, USA) operating in subharmonic mode (f(transmit): 2.5 MHz, f(receive): 1.25 MHz) was used to collect radiofrequency data at 10-40% incident acoustic power levels with 2-4 transmit cycles (in triplicate) before and after inducing PH. A pressure catheter (Millar Instruments, Inc., Houston, TX, USA) provided reference portal vein pressures. At optimum insonification, subharmonic signal amplitude changes correlated with portal vein pressure changes; r ranged from -0.82 to -0.94 and from -0.70 to -0.73 for PH models considered separately or together, respectively. The subharmonic signal amplitudes correlated with absolute portal vein pressures (r: -0.71 to -0.79). Statistically significant differences between subharmonic amplitudes, before and after inducing PH, were noted (p ≤ 0.01). Portal vein pressures estimated using subharmonic aided pressure estimation did not reveal significant differences (p > 0.05) with respect to the pressures obtained using the Millar pressure catheter. Subharmonic-aided pressure estimation may be useful clinically for portal vein pressure monitoring. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. Ultrasound-transmission parameter imaging in a photoacoustic imager

    NARCIS (Netherlands)

    Jose, J.; Jose, J.; Willemink, Rene; Resink, Steffen; Maalderink, T.; van Hespen, Johannes C.G.; van Leeuwen, Ton; Manohar, Srirang; Depeursinge, Christian D.; Vitkin, I. Alex

    2009-01-01

    We present a 'hybrid' imaging system, which can image both optical absorption properties and acoustic transmission properties of an object in a two-dimensional slice using a computed tomography photoacoustic imager. The ultrasound transmission measurement method uses a strong absorber of light which

  3. Needle Tip Visibility in 3D Ultrasound Images

    NARCIS (Netherlands)

    M. Arif (Muhammad); A. Moelker (Adriaan); T.W. van Walsum (Theo)

    2017-01-01

    textabstractAim: Needle visibility is crucial for effective and safe ultrasound-guided interventional procedures. Several studies have investigated needle visibility in 2D ultrasound imaging, but less information is available for 3D ultrasound imaging, a modality that has great potential for image

  4. Ultrasound imaging as an undergraduate physics laboratory exercise

    Science.gov (United States)

    Stiles, Timothy A.

    2014-05-01

    Ultrasound imaging provides an interesting and accessible example of the intersection between biology, medicine, and physics. This article provides a review of the physics and technology currently available and discusses two recent methods that have expanded the diagnostic capabilities of ultrasound imaging. We also describe two undergraduate physics laboratory exercises involving ultrasound imaging.

  5. High definition ultrasound imaging for battlefield medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, K.S.; Morimoto, A.K.; Kozlowski, D.M.; Krumm, J.C.; Dickey, F.M. [Sandia National Labs., Albuquerque, NM (United States); Rogers, B; Walsh, N. [Texas Univ. Health Science Center, San Antonio, TX (United States)

    1996-06-23

    A team has developed an improved resolution ultrasound system for low cost diagnostics. This paper describes the development of an ultrasound based imaging system capable of generating 3D images showing surface and subsurface tissue and bone structures. We include results of a comparative study between images obtained from X-Ray Computed Tomography (CT) and ultrasound. We found that the quality of ultrasound images compares favorably with those from CT. Volumetric and surface data extracted from these images were within 7% of the range between ultrasound and CT scans. We also include images of porcine abdominal scans from two different sets of animal trials.

  6. Tissue Harmonic Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Rasmussen, Joachim; Jensen, Jørgen Arendt

    2014-01-01

    with THI improves the image qual- ity compared to DRF-THI. The major benet of SASB is a reduced bandwidth between the probe and processing unit. A BK Medical 2202 Ultraview ultrasound scanner was used to acquire beamformed RF data for oine evaluation. The acquisition was made interleaved between methods...

  7. Ultrasound Imaging in Teaching Cardiac Physiology

    Science.gov (United States)

    Johnson, Christopher D.; Montgomery, Laura E. A.; Quinn, Joe G.; Roe, Sean M.; Stewart, Michael T.; Tansey, Etain A.

    2016-01-01

    This laboratory session provides hands-on experience for students to visualize the beating human heart with ultrasound imaging. Simple views are obtained from which students can directly measure important cardiac dimensions in systole and diastole. This allows students to derive, from first principles, important measures of cardiac function, such…

  8. Ultrasound Imaging Methods for Breast Cancer Detection

    NARCIS (Netherlands)

    Ozmen, N.

    2014-01-01

    The main focus of this thesis is on modeling acoustic wavefield propagation and implementing imaging algorithms for breast cancer detection using ultrasound. As a starting point, we use an integral equation formulation, which can be used to solve both the forward and inverse problems. This thesis

  9. Ultrasound imaging of the rabbit peroneal nerve

    NARCIS (Netherlands)

    B.S. de Kool (Stefan); J.W. van Neck (Han); J.H. Blok (Joleen); E.T. Walbeehm (Erik); J.M. Hekking-Weijma (Ineke); G.H. Visser (Gerhard Henk)

    2005-01-01

    textabstractUltrasound imaging of peripheral nerves is increasingly used in the clinic for a wide range of applications. Although yet unapplied for experimental neuroscience, it also has potential value in this research area. This study explores the feasibility, possibilities and limitations of this

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of North America ( ...

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... real-time images, images that are renewed continuously, it also can be used to guide procedures such ... of a testicle limiting proper blood flow into it. top of page How should we prepare for ...

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Pediatric radiologist scanning a boy's abdomen using ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  13. Sampling system for in vivo ultrasound images

    DEFF Research Database (Denmark)

    Jensen, Jorgen Arendt; Mathorne, Jan

    1991-01-01

    Newly developed algorithms for processing medical ultrasound images use the high frequency sampled transducer signal. This paper describes demands imposed on a sampling system suitable for acquiring such data and gives details about a prototype constructed. It acquires full clinical images at a s...... at a sampling frequency of 20 MHz with a resolution of 12 bits. The prototype can be used for real time image processing. An example of a clinical in vivo image is shown and various aspects of the data acquisition process are discussed....

  14. Micromachined Integrated Transducers for Ultrasound Imaging

    DEFF Research Database (Denmark)

    la Cour, Mette Funding

    The purpose of this project is to develop capacitive micromachined ultrasonic transducers (CMUTs) for medical imaging. Medical ultrasound transducers used today are fabricated using piezoelectric materials and bulk processing. To fabricate transducers capable of delivering a higher imaging...... characterizations are carried out successfully for both types of arrays. The arrays made at Stanford is found to suffer from low breakdown voltage of the supporting oxide and was not useful for medical imaging. The arrays made at DTU are used for various tests, both of the design, performance, possible packaging...... resolution it is however necessary to develop new fabrication methods that allows fabrication of transducer elements with smaller dimensions. By using microfabrication technology it is possible to push the dimensions down and provide higher design flexibility. This project is part of a large ultrasound...

  15. Automatic assessment of ultrasound image usability

    Science.gov (United States)

    Valente, Luca; Funka-Lea, Gareth; Stoll, Jeffrey

    2011-03-01

    We present a novel and efficient approach for evaluating the quality of ultrasound images. Image acquisition is sensitive to skin contact and transducer orientation and requires both time and technical skill to be done properly. Images commonly suffer degradation due to acoustic shadows and signal attenuation, which present as regions of low signal intensity masking anatomical details and making the images partly or totally unusable. As ultrasound image acquisition and analysis becomes increasingly automated, it is beneficial to also automate the estimation of image quality. Towards this end, we present an algorithm that classifies regions of an image as usable or un-usable. Example applications of this algorithm include improved compounding of free-hand 3D ultrasound volumes by eliminating unusable data and improved automatic feature detection by limiting detection to only usable areas. The algorithm operates in two steps. First, it classifies the image into bright areas, likely to have image content, and dark areas, likely to have no content. Second, it classifies the dark areas into unusable (i.e. due to shadowing and/or signal loss) and usable (i.e. anatomically accurate dark regions, such as with a blood vessel) sub-areas. The classification considers several factors, including statistical information, gradient intensity and geometric properties such as shape and relative position. Relative weighting of factors was obtained through the training of a Support Vector Machine. Classification results for both human and phantom images are presented and compared to manual classifications. This method achieves 91% sensitivity and 91% specificity for usable regions of human scans.

  16. Fast simulation of ultrasound images

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav

    2000-01-01

    Realistic B-mode and flow images can be simulated with scattering maps based on optical, CT, or MR images or parametric flow models. The image simulation often includes using 200,000 to 1 million point scatterers. One image line typically takes 1800 seconds to compute on a state-of-the-art PC...... be split among a number of PCs for speeding up the simulation. A full 3D one second volume simulation then takes 7,500 seconds on a 32 CPU 600 MHz Pentium III PC cluster....

  17. 3D ultrasound imaging for prosthesis fabrication and diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, A.K.; Bow, W.J.; Strong, D.S. [and others

    1995-06-01

    The fabrication of a prosthetic socket for a below-the-knee amputee requires knowledge of the underlying bone structure in order to provide pressure relief for sensitive areas and support for load bearing areas. The goal is to enable the residual limb to bear pressure with greater ease and utility. Conventional methods of prosthesis fabrication are based on limited knowledge about the patient`s underlying bone structure. A 3D ultrasound imaging system was developed at Sandia National Laboratories. The imaging system provides information about the location of the bones in the residual limb along with the shape of the skin surface. Computer assisted design (CAD) software can use this data to design prosthetic sockets for amputees. Ultrasound was selected as the imaging modality. A computer model was developed to analyze the effect of the various scanning parameters and to assist in the design of the overall system. The 3D ultrasound imaging system combines off-the-shelf technology for image capturing, custom hardware, and control and image processing software to generate two types of image data -- volumetric and planar. Both volumetric and planar images reveal definition of skin and bone geometry with planar images providing details on muscle fascial planes, muscle/fat interfaces, and blood vessel definition. The 3D ultrasound imaging system was tested on 9 unilateral below-the- knee amputees. Image data was acquired from both the sound limb and the residual limb. The imaging system was operated in both volumetric and planar formats. An x-ray CT (Computed Tomography) scan was performed on each amputee for comparison. Results of the test indicate beneficial use of ultrasound to generate databases for fabrication of prostheses at a lower cost and with better initial fit as compared to manually fabricated prostheses.

  18. Method and system to synchronize acoustic therapy with ultrasound imaging

    Science.gov (United States)

    Owen, Neil (Inventor); Bailey, Michael R. (Inventor); Hossack, James (Inventor)

    2009-01-01

    Interference in ultrasound imaging when used in connection with high intensity focused ultrasound (HIFU) is avoided by employing a synchronization signal to control the HIFU signal. Unless the timing of the HIFU transducer is controlled, its output will substantially overwhelm the signal produced by ultrasound imaging system and obscure the image it produces. The synchronization signal employed to control the HIFU transducer is obtained without requiring modification of the ultrasound imaging system. Signals corresponding to scattered ultrasound imaging waves are collected using either the HIFU transducer or a dedicated receiver. A synchronization processor manipulates the scattered ultrasound imaging signals to achieve the synchronization signal, which is then used to control the HIFU bursts so as to substantially reduce or eliminate HIFU interference in the ultrasound image. The synchronization processor can alternatively be implemented using a computing device or an application-specific circuit.

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... imaging of the abdomen is a safe, noninvasive test that uses sound waves to produce a clear ...

  20. Application of reinforcement learning for segmentation of transrectal ultrasound images

    OpenAIRE

    Sahba, Farhang; Tizhoosh, Hamid R; Salama, Magdy MA

    2008-01-01

    Abstract Background Among different medical image modalities, ultrasound imaging has a very widespread clinical use. But, due to some factors, such as poor image contrast, noise and missing or diffuse boundaries, the ultrasound images are inherently difficult to segment. An important application is estimation of the location and volume of the prostate in transrectal ultrasound (TRUS) images. For this purpose, manual segmentation is a tedious and time consuming procedure. Methods We introduce ...

  1. Lesion Contrast Enhancement in Medical Ultrasound Imaging

    DEFF Research Database (Denmark)

    Stetson, Paul F.; Sommer, F.G.; Macovski, A.

    1997-01-01

    Methods for improving the contrast-to-noise ratio (CNR) of low-contrast lesions in medical ultrasound imaging are described. Differences in the frequency spectra and amplitude distributions of the lesion and its surroundings can be used to increase the CNR of the lesion relative to the background....... Automated graylevel mapping is used in combination with a contrast-weighted form of frequency-diversity speckle reduction. In clinical studies, the techniques have yielded mean CNR improvements of 3.2 dB above ordinary frequency-diversity imaging and 5.6 dB over sharper conventional images, with no post...

  2. On the implementation of an automated acoustic output optimization algorithm for subharmonic aided pressure estimation.

    Science.gov (United States)

    Dave, J K; Halldorsdottir, V G; Eisenbrey, J R; Merton, D A; Liu, J B; Machado, P; Zhao, H; Park, S; Dianis, S; Chalek, C L; Thomenius, K E; Brown, D B; Forsberg, F

    2013-04-01

    Incident acoustic output (IAO) dependent subharmonic signal amplitudes from ultrasound contrast agents can be categorized into occurrence, growth or saturation stages. Subharmonic aided pressure estimation (SHAPE) is a technique that utilizes growth stage subharmonic signal amplitudes for hydrostatic pressure estimation. In this study, we developed an automated IAO optimization algorithm to identify the IAO level eliciting growth stage subharmonic signals and also studied the effect of pulse length on SHAPE. This approach may help eliminate the problems of acquiring and analyzing the data offline at all IAO levels as was done in previous studies and thus, pave the way for real-time clinical pressure monitoring applications. The IAO optimization algorithm was implemented on a Logiq 9 (GE Healthcare, Milwaukee, WI) scanner interfaced with a computer. The optimization algorithm stepped the ultrasound scanner from 0% to 100% IAO. A logistic equation fitting function was applied with the criterion of minimum least squared error between the fitted subharmonic amplitudes and the measured subharmonic amplitudes as a function of the IAO levels and the optimum IAO level was chosen corresponding to the inflection point calculated from the fitted data. The efficacy of the optimum IAO level was investigated for in vivo SHAPE to monitor portal vein (PV) pressures in 5 canines and was compared with the performance of IAO levels, below and above the optimum IAO level, for 4, 8 and 16 transmit cycles. The canines received a continuous infusion of Sonazoid microbubbles (1.5 μl/kg/min; GE Healthcare, Oslo, Norway). PV pressures were obtained using a surgically introduced pressure catheter (Millar Instruments, Inc., Houston, TX) and were recorded before and after increasing PV pressures. The experiments showed that optimum IAO levels for SHAPE in the canines ranged from 6% to 40%. The best correlation between changes in PV pressures and in subharmonic amplitudes (r=-0.76; p=0

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... display screen that looks like a computer or television monitor. The image is created based on the ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Science.gov (United States)

    ... display screen that looks like a computer or television monitor. The image is created based on the ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Send us your feedback Did you find the information you were looking for? Yes No Please type ... facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  7. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... The image is created based on the amplitude (loudness), frequency (pitch) and time it takes for the ... transducer for analysis. top of page This page was reviewed on February 17, 2017 Send us your ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... images and send a signed report to your primary care physician, or to the physician or other healthcare provider who requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index ...

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... imaging tests, treatments and procedures may vary by geographic region. Discuss the fees associated with your prescribed ... Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. ( ...

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z ...

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... to have your child drink several glasses of water, depending on the child's size, two hours prior ... improve the quality of the images. A clear water-based gel is applied to the area of ...

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... screen that looks like a computer or television monitor. The image is created based on the amplitude ( ... turn creates a real-time picture on the monitor. One or more frames of the moving pictures ...

  14. The effect of binding on the subharmonic emissions from individual lipid-encapsulated microbubbles at transmit frequencies of 11 and 25 MHz.

    Science.gov (United States)

    Helfield, Brandon L; Cherin, Emmanuel; Foster, F Stuart; Goertz, David E

    2013-02-01

    Targeted microbubble imaging at ultrasound frequencies above 5 MHz has applications in both a preclinical context for a range of disease processes and clinically for the assessment of atherosclerosis and superficial tumors. Although the feasibility of ultrasound molecular imaging has been well demonstrated for a range of target molecules, little work has examined the effects of binding on microbubble oscillations, which is of potential relevance to improving the sensitivity, specificity, and quantification of bound-bubble detection. In this study we investigated the influence of binding on the subharmonic response of bubbles at transmit frequencies of 11 and 25 MHz. Individual bubbles were situated adjacent to a boundary in either a bound or an unbound state, optically sized and acoustically interrogated with pressures ranging from 0.02 to 1.2 MPa. At 11 MHz, unbound bubbles (n = 53) were found to have strong subharmonic activity for sizes between 2.4 and 2.6 μm, whereas bound bubbles (n = 50) were most active from 2.6 to 3.0 μm. Destruction thresholds were found to be lower for bound bubbles. At 25 MHz, bound-bubble (n = 57) activity was found to peak at 1.9 μm as compared to 2.1 μm in the unbound cases (n = 53), with a 20% increase in amplitude. Comparison with simulations indicates that both unbound and bound bubbles undergo compression-only behavior at 11 MHz, and expansion-dominated behavior at 25 MHz. Subharmonic emissions elicited from 0 radian transmit pulses were found to be π/2 radians out of phase with those elicited from a π radian transmit pulse, suggesting inefficient subharmonic preservation from pulse inversion schemes. With the appropriate postprocessed phase correction, an increase in the subharmonic amplitude of up to 60% was shown, depending on the bubble size and transmit frequency. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Methods and systems for producing compounded ultrasound images

    DEFF Research Database (Denmark)

    2012-01-01

    Disclosed is a method for producing compounded ultrasound images by beamforming a first and a second low-resolution image using data from a first ultrasound emission, beamforming a third and a fourth low-resolution image using data from a second ultrasound emission, summing said first and said...... third low-resolution image creating a first high-resolution image and said second and said fourth low-resolution image creating a second high-resolution image, wherein the method further comprises computing a first envelope image for said first high-resolution image and a second envelope image for said...

  16. An open access thyroid ultrasound image database

    Science.gov (United States)

    Pedraza, Lina; Vargas, Carlos; Narváez, Fabián.; Durán, Oscar; Muñoz, Emma; Romero, Eduardo

    2015-01-01

    Computer aided diagnosis systems (CAD) have been developed to assist radiologists in the detection and diagnosis of abnormalities and a large number of pattern recognition techniques have been proposed to obtain a second opinion. Most of these strategies have been evaluated using different datasets making their performance incomparable. In this work, an open access database of thyroid ultrasound images is presented. The dataset consists of a set of B-mode Ultrasound images, including a complete annotation and diagnostic description of suspicious thyroid lesions by expert radiologists. Several types of lesions as thyroiditis, cystic nodules, adenomas and thyroid cancers were included while an accurate lesion delineation is provided in XML format. The diagnostic description of malignant lesions was confirmed by biopsy. The proposed new database is expected to be a resource for the community to assess different CAD systems.

  17. Fast and Automatic Ultrasound Simulation from CT Images

    OpenAIRE

    Weijian Cong; Jian Yang; Yue Liu; Yongtian Wang

    2013-01-01

    Ultrasound is currently widely used in clinical diagnosis because of its fast and safe imaging principles. As the anatomical structures present in an ultrasound image are not as clear as CT or MRI. Physicians usually need advance clinical knowledge and experience to distinguish diseased tissues. Fast simulation of ultrasound provides a cost-effective way for the training and correlation of ultrasound and the anatomic structures. In this paper, a novel method is proposed for fast simulation of...

  18. Adaptive Beamforming for Medical Ultrasound Imaging

    DEFF Research Database (Denmark)

    Holfort, Iben Kraglund

    This dissertation investigates the application of adaptive beamforming for medical ultrasound imaging. The investigations have been concentrated primarily on the Minimum Variance (MV) beamformer. A broadband implementation of theMV beamformer is described, and simulated data have been used...... of the influence of sound speed errors on the adaptive beamformers; MV and the Amplitude and Phase EStimation (APES) beamformer. Furthermore, the investigations of previously suggested adaptive spectral Doppler techniques are continued by additional in-vivo measurements. These investigations shows...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological Society of North America, Inc. ( ...

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary so that any change in a known abnormality can be monitored over ...

  1. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... be turned to either side to improve the quality of the images. A clear water-based gel is applied to the area of the body being studied to help the transducer make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... medical test that helps physicians diagnose and treat medical ... a catheter or other drainage device and helps assure safe and accurate placement and ...

  3. Impact of element pitch on synthetic aperture ultrasound imaging

    NARCIS (Netherlands)

    Hasegawa, H.; Korte, C.L. de

    2016-01-01

    PURPOSE: Synthetic aperture imaging was introduced in medical ultrasound to obtain high-quality images. In synthetic aperture ultrasound imaging, spherical transmit waves illuminate a target region from different positions, resulting in low-resolution images for each transmission. By coherent

  4. Imaging modalities in Focal Therapy: Multiparametric Ultrasound.

    Science.gov (United States)

    Wildeboer, R R; Panfilova, A P; Mischi, M; Wijkstra, H

    2016-07-01

    Prostate cancer (PCa) is the most common form of cancer among men in the US and the second most common cause of death. It has been observed that an increasing number of newly diagnosed patients exhibit low-risk features and that over-treatment with radical prostatectomy is a growing problem. The feasibility of focal therapy as an organsparing alternative, however, depends on the reliability of imaging techniques to identify, localize and monitor clinically relevant PCa lesions. The aim of this review is to investigate the potential of multiparametric ultrasound (mpUS) for focal therapy. We briefly introduce the most common focal therapies and thoroughly discuss the ability of available ultrasound modalities to localize PCa and reflect tissue properties. The imaging requirements of the focal therapies are studied to put the performance of the US techniques into perspective. We found that transrectal greyscale echography, Doppler sonography, elastography, contrast-enhanced ultrasonography and computerized ultrasound have been studied for the purpose of prostate imaging. Several of these modalities are already frequently used in current clinical practice; to add to the diagnostic process of PCa, to guide and monitor the application of focal therapy or to perform follow-up after treatment. Despite their capability to detect a large fraction of the PCa lesions, none of these modalities is currently considered sufficiently accurate for stand-alone tumour detection and localization. However, although there are only few studies reporting on a combined use of different ultrasound modalities, the results of an mpUS approach seem promising. Several US modalities have been successfully applied as a viable alternative to monitor tissue destruction during and after treatment. In view of the advantages of US and the promising results of a multiparametric approach in PCa detection and localization, researchers are urged to further investigate mpUS for therapeutic purposes.

  5. Rehabilitative ultrasound imaging: understanding the technology and its applications.

    Science.gov (United States)

    Whittaker, Jackie L; Teyhen, Deydre S; Elliott, James M; Cook, Katy; Langevin, Helene M; Dahl, Haldis H; Stokes, Maria

    2007-08-01

    The use of ultrasound imaging by physical therapists is growing in popularity. This commentary has 2 aims. The first is to introduce the concept of rehabilitative ultrasound imaging (RUSI), provide a definition of the scope of this emerging tool in regard to the physical therapy profession, and describe how this relates to the larger field of medical ultrasound imaging. The second aim is to provide an overview of basic ultrasound imaging and instrumentation principles, including an understanding of the various modes and applications of the technology with respect to neuromusculoskeletal rehabilitation and in relation to other common imaging modalities.

  6. APES Beamforming Applied to Medical Ultrasound Imaging

    DEFF Research Database (Denmark)

    Blomberg, Ann E. A.; Holfort, Iben Kraglund; Austeng, Andreas

    2009-01-01

    Recently, adaptive beamformers have been introduced to medical ultrasound imaging. The primary focus has been on the minimum variance (MV) (or Capon) beamformer. This work investigates an alternative but closely related beamformer, the Amplitude and Phase Estimation (APES) beamformer. APES offers...... added robustness at the expense of a slightly lower resolution. The purpose of this study was to evaluate the performance of the APES beamformer on medical imaging data, since correct amplitude estimation often is just as important as spatial resolution. In our simulations we have used a 3.5 MHz, 96...... element linear transducer array. When imaging two closely spaced point targets, APES displays nearly the same resolution as the MV, and at the same time improved amplitude control. When imaging cysts in speckle, APES offers speckle statistics similar to that of the DAS, without the need for temporal...

  7. Broadband ultrasound attenuation imaging: a new imaging method in osteoporosis.

    Science.gov (United States)

    Roux, C; Fournier, B; Laugier, P; Chappard, C; Kolta, S; Dougados, M; Berger, G

    1996-08-01

    The purpose of this study was to evaluate the usefulness in osteoporosis of a new ultrasound imaging device able to create a parametric image of broadband ultrasound attenuation (BUA) at the os calcis. Three regions of interest were located in the great tuberosity of the os calcis. Precision was evaluated in 37 patients. Calcaneal bone mineral density (BMD) and BUA were compared in 33 patients. In 236 patients (including 77 with osteoporotic fractures), BUA and lumbar and femoral BMD measurements were performed. The measurements were compared using correlation coefficients. Their clinical value was estimated by comparisons of the results between patients with fractures and age-matched controls, using comparisons of the means, areas under the ROC curves, and logistic regression. Precision was in a 1.4-3.3% range. Local BUA and BMD were highly correlated (r = 0.88). Significant correlations were found between BUA and lumbar (r = 0.56) and femur (r = 0.66) BMD. In multiple regression, years since menopause and weight were significant predictors of BUA. Patients with fractures had lower BUA and BMD than age-matched controls. BUA showed the largest difference between the two populations (13-16%). Areas under the ROC curves were similar for BUA and BMD. Logistic regression after adjustment for confounding factors showed that BUA discriminated between fracture and nonfracture subjects. Broadband ultrasound attenuation imaging improves the reproducibility of ultrasound measurements. It may be useful in osteoporosis, due to its good discriminating value.

  8. Rehabilitative ultrasound imaging of the abdominal muscles.

    Science.gov (United States)

    Teyhen, Deydre S; Gill, Norman W; Whittaker, Jackie L; Henry, Sharon M; Hides, Julie A; Hodges, Paul

    2007-08-01

    Rehabilitative ultrasound imaging (RUSI) of the abdominal muscles is increasingly being used in the management of conditions involving musculoskeletal dysfunctions associated with the abdominal muscles, including certain types of low back and pelvic pain. This commentary provides an overview of current concepts and evidence related to RUSI of the abdominal musculature, including issues addressing the potential role of ultrasound imaging in the assessment and training of these muscles. Both quantitative and qualitative aspects associated with clinical and research applications are considered, as are the possible limitations related to the interpretation of measurements made with RUSI. Research to date has utilized a range of methodological approaches, including different transducer placements and imaging techniques. The pros and cons of the various methods are discussed, and guidelines for future investigations are presented. Potential implications and opportunities for clinical use of RUSI to enhance evidence-based practice are outlined, as are suggestions for future research to further clarify the possible role of RUSI in the evaluation and treatment of abdominal muscular morphology and function.

  9. Consider ultrasound first for imaging the female pelvis.

    Science.gov (United States)

    Benacerraf, Beryl R; Abuhamad, Alfred Z; Bromley, Bryann; Goldstein, Steven R; Groszmann, Yvette; Shipp, Thomas D; Timor-Tritsch, Ilan E

    2015-04-01

    Ultrasound technology has evolved dramatically in recent years and now includes applications such as 3-dimensional volume imaging, real-time evaluation of pelvic organs (simultaneous with the physical examination), and Doppler blood flow mapping without the need for contrast, which makes ultrasound imaging unique for imaging the female pelvis. Among the many cross-sectional imaging techniques, we should use the most informative, less invasive, and less expensive modality to avoid radiation when possible. Hence, ultrasound imaging should be the first imaging modality used in women with pelvic symptoms. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Harmonic ultrasound imaging using synthetic aperture sequential beamforming

    DEFF Research Database (Denmark)

    2012-01-01

    A method includes generating an ultrasound image based on the harmonic components in the received echoes using multi-stage beam forming and data generated therefrom. An ultrasound imaging system (100, 200) includes a transducer array (108) including a plurality of transducer elements configured t....... The ultrasound imaging system further includes a synthetic aperture processor (128), including a second beam former (130) configured to process the stored intermediate scan lines, based on a synthetic aperture algorithm, generating a focused image.......A method includes generating an ultrasound image based on the harmonic components in the received echoes using multi-stage beam forming and data generated therefrom. An ultrasound imaging system (100, 200) includes a transducer array (108) including a plurality of transducer elements configured...... to emit ultrasound signals and receive echoes generated in response to the emitted ultrasound signals. The ultrasound imaging system further includes transmit circuitry (1 10) that generates a set of pulses that actuate a set of the plurality of transducer elements to emit ultrasound signals...

  11. Contrast-enhanced ultrasound for molecular imaging of angiogenesis.

    Science.gov (United States)

    Eisenbrey, J R; Forsberg, F

    2010-08-01

    Molecular imaging of angiogenesis using contrast-enhanced ultrasound allows for functional, real-time, inexpensive imaging of angiogenesis. The addition of stabilized microbubbles as contrast agents greatly improves ultrasound signal to noise ratio/signal strength/image quality (up to 25 dB) and allows for imaging of angiogenic vasculature. In this article recent advances in the usage of contrast-enhanced ultrasound for molecular imaging of angiogenesis are reviewed. The usage of commercially available agents and correlations between their imaging parameters and molecular markers of angiogenesis are reviewed. Recent developments in ultrasound contrast agents targeted to angiogenic markers for both diagnosis and monitoring are discussed. Finally, a brief overview of the emerging field of chemotherapeutic-loaded agents, which can be used with ultrasound-triggered drug delivery, is provided.

  12. Basic physics and imaging characteristics of ultrasound.

    Science.gov (United States)

    Kossoff, G

    2000-02-01

    The imaging characteristics of diagnostic ultrasound (US) are determined by the ultrasonic properties of tissue. The velocity of propagation of US and the attenuation are the 2 most important parameters. These determine the frequency with which the tissues may be imaged, which in turn sets a fundamental limit on the axial and the lateral resolution. Ultrasonic imaging equipment is designed on the premise that the ultrasonic energy propagates through tissue in a straight line and that the ultrasonic beam is very narrow. In fact, the ultrasonic energy propagates through tissue as a beam of finite dimensions set by the physical dimensions of the transducer, the way it is constructed, and the way it is energized. Also, the velocity of propagation in different tissues varies and this can lead to deviation of the ultrasonic beam from the assumed direction of propagation. This breakdown in assumptions leads to the creation of artifacts that must be appreciated in the interpretation of ultrasonic images. For this reason skilled interpreters of ultrasonic images follow 3 golden rules: never make an interpretation on a single image; just because a feature is displayed do not consider that it is necessarily real; and just because a feature is not displayed do not consider that it is necessarily not there.

  13. Ultrasound: A novel tool for airway imaging

    Directory of Open Access Journals (Sweden)

    Siddharthkumar Bhikhabhai Parmar

    2014-01-01

    Full Text Available Context: The scope of ultrasound is emerging in medical science, particularly outside traditional areas of radiology practice. Aims: We designed this study to evaluate feasibility of bedside sonography as a tool for airway assessment and to describe sonographic anatomy of airway. Settings and Design: A prospective, clinical study. Materials and Methods: We included 100 adult, healthy volunteers of either sex to undergo airway imaging systemically starting from floor of the mouth to the sternal notch in anterior aspect of neck by sonography. Results: We could visualize mandible and hyoid bone as a bright hyperechoic structure with hypoechoic acoustic shadow underneath. Epiglottis, thyroid cartilage, cricoid cartilage, and tracheal rings appeared hypoechoic. Vocal cords were visualized through thyroid cartilage. Interface between air and mucosa lining the airway produced a bright hyperechoic linear appearance. Artifacts created by intraluminal air prevented visualization of posterior pharynx, posterior commissure, and posterior wall of trachea. Conclusions: Ultrasound is safe, quick, noninvasive, repeatable, and bedside tool to assess the airway and can provide real-time dynamic images relevant for several aspects of airway management.

  14. Physics of tissue harmonic imaging by ultrasound

    Science.gov (United States)

    Jing, Yuan

    Tissue Harmonic Imaging (THI) is an imaging modality that is currently deployed on diagnostic ultrasound scanners. In THI the amplitude of the ultrasonic pulse that is used to probe the tissue is large enough that the pulse undergoes nonlinear distortion as it propagates into the tissue. One result of the distortion is that as the pulse propagates energy is shifted from the fundamental frequency of the source pulse into its higher harmonics. These harmonics will scatter off objects in the tissue and images formed from the scattered higher harmonics are considered to have superior quality to the images formed from the fundamental frequency. Processes that have been suggested as possibly responsible for the improved imaging in THI include: (1) reduced sensitivity to reverberation, (2) reduced sensitivity to aberration, and (3) reduction in side lobes. By using a combination of controlled experiments and numerical simulations, these three reasons have been investigated. A single element transducer and a clinical ultrasound scanner with a phased array transducer were used to image a commercial tissue-mimicking phantom with calibrated targets. The higher image quality achieved with THI was quantified in terms of spatial resolution and "clutter" signals. A three-dimensional model of the forward propagation of nonlinear sound beams in media with arbitrary spatial properties (a generalized KZK equation) was developed. A time-domain code for solving the KZK equation was validated with measurements of the acoustic field generated by the single element transducer and the phased array transducer. The code was used to investigate the impact of aberration using tissue-like media with three-dimensional variations in all acoustic properties. The three-dimensional maps of tissue properties were derived from the datasets available through the Visible Female project. The experiments and simulations demonstrated that second harmonic imaging (1) suffers less clutter associated with

  15. Interference-free ultrasound imaging during HIFU therapy, using software tools

    Science.gov (United States)

    Vaezy, Shahram (Inventor); Held, Robert (Inventor); Sikdar, Siddhartha (Inventor); Managuli, Ravi (Inventor); Zderic, Vesna (Inventor)

    2010-01-01

    Disclosed herein is a method for obtaining a composite interference-free ultrasound image when non-imaging ultrasound waves would otherwise interfere with ultrasound imaging. A conventional ultrasound imaging system is used to collect frames of ultrasound image data in the presence of non-imaging ultrasound waves, such as high-intensity focused ultrasound (HIFU). The frames are directed to a processor that analyzes the frames to identify portions of the frame that are interference-free. Interference-free portions of a plurality of different ultrasound image frames are combined to generate a single composite interference-free ultrasound image that is displayed to a user. In this approach, a frequency of the non-imaging ultrasound waves is offset relative to a frequency of the ultrasound imaging waves, such that the interference introduced by the non-imaging ultrasound waves appears in a different portion of the frames.

  16. Noninvasive estimation of dynamic pressures in vitro and in vivo using the subharmonic response from microbubbles.

    Science.gov (United States)

    Dave, Jaydev K; Halldorsdottir, Valgerdur G; Eisenbrey, John R; Liu, Ji-Bin; McDonald, Maureen E; Dickie, Kris; Leung, Corina; Forsberg, Flemming

    2011-10-01

    The purpose of this study was to develop and validate a noninvasive pressure estimation technique based on subharmonic emissions from a commercially available ultrasound contrast agent and scanner, unlike other studies that have either adopted a single-element transducer approach and/ or use of in-house contrast agents. Ambient pressures were varied in a closed-loop flow system between 0 and 120 mmHg and were recorded by a solid-state pressure catheter as the reference standard. Simultaneously, the ultrasound scanner was operated in pulse inversion mode transmitting at 2.5 MHz, and the unprocessed RF data were captured at different incident acoustic pressures (from 76 to 897 kPa). The subharmonic data for each pulse were extracted using band-pass filtering with averaging, and subsequently processed to eliminate noise. The incident acoustic pressure most sensitive to ambient pressure fluctuations was determined, and then the ambient pressure was tracked over 20 s. In vivo validation of this technique was performed in the left ventricle (LV) of 2 canines. In vitro, the subharmonic signal could track ambient pressure values with r(2) = 0.922 (p 0.790 (p < 0.001) showing a maximum error of 2.84 mmHg compared with the reference standard. In conclusion, a subharmonic ultrasound-based pressure estimation technique, which can accurately track left ventricular pressures, has been established.

  17. The Application of Contrast Enhanced Ultrasound in Molecular Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hak Jong; Chung, Jin Haeung; Hwang, Sung Il [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2009-09-15

    Microbubble contrast agent for ultrasound imaging has come of age, adding entirely new capabilities to real time ultrasound imaging. These new ultrasound imaging techniques exploit the nonlinear echoes that result from the unique interaction between ultrasound and microbubbles, which are readily distinguishable from the echoes of tissues. Contrast enhanced ultrasound can be used to quantify both flow rate and relative vascular volume of the microvasculature in solid lesions or organs, which makes it possible for it to be one of the modalities in molecular imaging. Angiogenesis is one of the important processes contributing to new blood vessel growth that occurs in a variety of physiologic and pathophysiologic states. It is essential for spread and growth of malignant tumors. The advantages of contrast enhanced ultrasound are that it is a noninvasive method for observing tumor angiogenesis. Sonoporation utilizes the interaction of ultrasound with ultrasound contrast agents to temporarily permeabilized the cell membrane allowing for the uptake of DNA, drugs, and other therapeutic compounds from the extracellular environment. Thus, sonoporation is a promising drug delivery and gene therapy technique, limited only by lack of understanding regarding the biophysical mechanism that results in the cell membrane permeability change. In conclusion, ultrasound contrast agent could have a role not only in the molecular imaging field with the advantage of noninvasive quantification of angiogenesis, but also in the field of drug treatment of cells using sonoporation

  18. Imaging of Groin Pain: Magnetic Resonance and Ultrasound Imaging Features.

    Science.gov (United States)

    Lee, Susan C; Endo, Yoshimi; Potter, Hollis G

    Evaluation of groin pain in athletes may be challenging as pain is typically poorly localized and the pubic symphyseal region comprises closely approximated tendons and muscles. As such, magnetic resonance imaging (MRI) and ultrasound (US) may help determine the etiology of groin pain. A PubMed search was performed using the following search terms: ultrasound, magnetic resonance imaging, sports hernia, athletic pubalgia, and groin pain. Date restrictions were not placed on the literature search. Clinical review. Level 4. MRI is sensitive in diagnosing pathology in groin pain. Not only can MRI be used to image rectus abdominis/adductor longus aponeurosis and pubic bone pathology, but it can also evaluate other pathology within the hip and pelvis. MRI is especially helpful when groin pain is poorly localized. Real-time capability makes ultrasound useful in evaluating the pubic symphyseal region, as it can be used for evaluation and treatment. MRI and US are valuable in diagnosing pathology in athletes with groin pain, with the added utility of treatment using US-guided intervention. Strength-of Recommendation Taxonomy: C.

  19. Integrated intravascular optical coherence tomography (OCT) - ultrasound (US) imaging system

    Science.gov (United States)

    Yin, Jiechen; Yang, Hao-Chung; Li, Xiang; Zhou, Qifa; Hu, Changhong; Zhang, Jun; Shung, K. Kirk; Chen, Zhongping

    2010-02-01

    Optical coherence tomography (OCT) and intravascular ultrasound (IVUS) are considered two complementary imaging techniques in the detection and diagnosis of atherosclerosis. OCT permits visualization of micron-scale features of atherosclerosis plaque, and IVUS offers full imaging depth of vessel wall. Under the guidance of IVUS, minimal amount of flushing agent will be needed to obtain OCT imaging of the interested area. We report on a dual-modality optical coherence tomography (OCT) - ultrasound (US) system for intravascular imaging. To the best of our knowledge, we have developed the first integrated OCT-US probe that combines OCT optical components with an ultrasound transducer. The OCT optical components mainly consist of a single mode fiber, a gradient index (GRIN) lens for light beam focusing, and a right-angled prism for reflecting light into biological tissue. A 40MHz PZT-5H side-viewing ultrasound transducer was fabricated to obtain the ultrasound image. These components were integrated into a single probe, enabling both OCT and ultrasound imaging at the same time. In vitro OCT and ultrasound images of a rabbit aorta were obtained using this dual-modality imaging system. This study demonstrates the feasibility of an OCT-US system for intravascular imaging which is expected to have a prominent impact on early detection and characterization of atherosclerosis.

  20. A new architecture for fast ultrasound imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cruza, J. F. [Instituto de Tecnologías Físicas y de la Información ' ' Torres Quevedo' ' Consejo Superior de Investigaciones Científicas (CSIC), Serrano 144, 28006 Madrid (Spain); Camacho, J.; Moreno, J. M.; Medina, L. [Instituto de Tecnologías Físicas y de la Información Torres Quevedo Consejo Superior de Investigaciones Científicas (CSIC), Serrano 144, 28006 Madrid (Spain)

    2014-02-18

    Some ultrasound imaging applications require high frame rate, for example 3D imaging and automated inspections of large components. Being the signal-processing throughput of the system the main bottleneck, parallel beamforming is required to achieve hundreds to thousands of images per second. Simultaneous A-scan line beamforming in all active channels is required to reach the intended high frame rate. To this purpose, a new parallel beamforming architecture that exploits the currently available processing resources available in state-of-the-art FPGAs is proposed. The work aims to get the optimal resource usage, high scalability and flexibility for different applications. To achieve these goals, the basic beamforming function is reformulated to be adapted to the DSP-cell architecture of state-of-the-art FPGAs. This allows performing simultaneous dynamic focusing on multiple A-scan lines. Some realistic examples are analyzed, evaluating resource requirements and maximum operating frequency. For example, a 128-channel system, with 128 scan lines and acquiring at 20 MSPS, can be built with 4 mid-range FPGAs, achieving up to 18000 frames per second, just limited by the maximum PRF. The gold standard Synthetic Transmit Aperture method (also called Total Focusing Method) can be carried out in real time at a processing rate of 140 high-resolution images per second (16 cm depth on steel)

  1. Despeckle filtering for ultrasound imaging and video II selected applications

    CERN Document Server

    Loizou, Christos P

    2015-01-01

    In ultrasound imaging and video visual perception is hindered by speckle multiplicative noise that degrades the quality. Noise reduction is therefore essential for improving the visual observation quality or as a pre-processing step for further automated analysis, such as image/video segmentation, texture analysis and encoding in ultrasound imaging and video. The goal of the first book (book 1 of 2 books) was to introduce the problem of speckle in ultrasound image and video as well as the theoretical background, algorithmic steps, and the MatlabTM for the following group of despeckle filters:

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound ... limitations of Pelvic Ultrasound Imaging? What is Pelvic Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  3. SVM-Based CAC System for B-Mode Kidney Ultrasound Images

    National Research Council Canada - National Science Library

    Subramanya, M B; Kumar, Vinod; Mukherjee, Shaktidev; Saini, Manju

    2015-01-01

    .... normal, medical renal disease (MRD) and cyst using B-mode ultrasound images. Thirty-five B-mode kidney ultrasound images consisting of 11 normal images, 8 MRD images and 16 cyst images have been used...

  4. Ultrasound: medical imaging and beyond (an invited review).

    Science.gov (United States)

    Azhari, Haim

    2012-09-01

    Medical applications of ultrasound were first investigated about seventy years ago. It has rapidly evolved since then, becoming an essential tool in medical imaging. Ultrasound ability to provide real time images with frame rates exceeding several hundred frames per second allows one to view rapid anatomical changes as well as to guide minimal invasive procedures. By, combining Doppler techniques with anatomical images ultrasound provides real time quantitative flow information as well. It is portable, versatile, cost effective and considered sufficiently hazardless to monitor pregnancy. Moreover, ultrasound has the unique capacity to offer therapeutic capabilities in addition to its outstanding imaging abilities. It can be used for physiotherapy, lithotripsy, and thermal ablation, and recent studies have demonstrated its usefulness in drug delivery, gene therapy and molecular imaging. The purpose of this article is to provide an introductory review of the field covering briefly topics from basic physics through current imaging methods to therapeutic applications.

  5. Fast and Automatic Ultrasound Simulation from CT Images

    Directory of Open Access Journals (Sweden)

    Weijian Cong

    2013-01-01

    Full Text Available Ultrasound is currently widely used in clinical diagnosis because of its fast and safe imaging principles. As the anatomical structures present in an ultrasound image are not as clear as CT or MRI. Physicians usually need advance clinical knowledge and experience to distinguish diseased tissues. Fast simulation of ultrasound provides a cost-effective way for the training and correlation of ultrasound and the anatomic structures. In this paper, a novel method is proposed for fast simulation of ultrasound from a CT image. A multiscale method is developed to enhance tubular structures so as to simulate the blood flow. The acoustic response of common tissues is generated by weighted integration of adjacent regions on the ultrasound propagation path in the CT image, from which parameters, including attenuation, reflection, scattering, and noise, are estimated simultaneously. The thin-plate spline interpolation method is employed to transform the simulation image between polar and rectangular coordinate systems. The Kaiser window function is utilized to produce integration and radial blurring effects of multiple transducer elements. Experimental results show that the developed method is very fast and effective, allowing realistic ultrasound to be fast generated. Given that the developed method is fully automatic, it can be utilized for ultrasound guided navigation in clinical practice and for training purpose.

  6. Fast and automatic ultrasound simulation from CT images.

    Science.gov (United States)

    Cong, Weijian; Yang, Jian; Liu, Yue; Wang, Yongtian

    2013-01-01

    Ultrasound is currently widely used in clinical diagnosis because of its fast and safe imaging principles. As the anatomical structures present in an ultrasound image are not as clear as CT or MRI. Physicians usually need advance clinical knowledge and experience to distinguish diseased tissues. Fast simulation of ultrasound provides a cost-effective way for the training and correlation of ultrasound and the anatomic structures. In this paper, a novel method is proposed for fast simulation of ultrasound from a CT image. A multiscale method is developed to enhance tubular structures so as to simulate the blood flow. The acoustic response of common tissues is generated by weighted integration of adjacent regions on the ultrasound propagation path in the CT image, from which parameters, including attenuation, reflection, scattering, and noise, are estimated simultaneously. The thin-plate spline interpolation method is employed to transform the simulation image between polar and rectangular coordinate systems. The Kaiser window function is utilized to produce integration and radial blurring effects of multiple transducer elements. Experimental results show that the developed method is very fast and effective, allowing realistic ultrasound to be fast generated. Given that the developed method is fully automatic, it can be utilized for ultrasound guided navigation in clinical practice and for training purpose.

  7. Programmable ultrasound imaging using multimedia technologies: a next-generation ultrasound machine.

    Science.gov (United States)

    Kim, Y; Kim, J H; Basoglu, C; Winter, T C

    1997-03-01

    High computational and throughput requirements in modern ultrasound machines have restricted their internal design to algorithm-specific hardware with limited programmability. We have architected a programmable ultrasound processing system, Programmable Ultrasound Image Processor (PUIP), to facilitate engineering and clinical ultrasound innovations. Multiple high-performance multimedia processors were used to provide a computing power of 4 billion operations per second. Flexibility was achieved by making our system programmable and multimodal, e.g., B-mode, color flow, cine and Doppler data can be processed. We have successfully designed and implemented the PUIP to fit within an ultrasound machine. It provides a platform for rapid testing of new concepts in ultrasound processing and enables software upgrades for future technologies. Current and future clinical applications include extended fields of view, quantitative measurements, three-dimensional ultrasound reconstruction and visualization, adaptive persistence, speckle reduction, edge enhancement, image segmentation, and motion analysis. The PUIP is a significant step in the evolution of ultrasound machines toward more flexible and generalized systems bridging the gap between many innovative ideas and their clinical use in ultrasound machines.

  8. l1-norm regularized beamforming in ultrasound imaging

    OpenAIRE

    Szasz, Teodora; Basarab, Adrian; Kouamé, Denis

    2016-01-01

    International audience; This paper is part of the challenge on plane wave imaging in medical ultrasound , organized during the IEEE International Ultrasonics Symposium 2016 in Tours (France). Herein, we address beamforming in ultrasound imaging, by formulating it, for each image depth, as an inverse problem solved using Laplacian prior through Basis Pursuit (BP). This approach was evaluated for the four different categories proposed for the competition, using 1, 11, 75 plane waves, and for th...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  10. Imaging nonmelanoma skin cancers with combined ultrasound-photoacoustic microscopy

    Science.gov (United States)

    Sunar, Ulas; Rohrbach, Daniel J.; Morgan, Janet; Zeitouni, Natalie

    2013-03-01

    PDT has become a treatment of choice especially for the cases with multiple sites and large areas. However, the efficacy of PDT is limited for thicker and deeper tumors. Depth and size information as well as vascularity can provide useful information to clinicians for planning and evaluating PDT. High-resolution ultrasound and photoacoustic imaging can provide information regarding skin structure and vascularity. We utilized combined ultrasound-photoacoustic microscopy for imaging a basal cell carcinoma (BCC) tumor pre-PDT and the results indicate that combined ultrasound-photoacoustic imaging can be useful tool for PDT planning by providing both structural and functional contrasts.

  11. Real-time image fusion involving diagnostic ultrasound

    DEFF Research Database (Denmark)

    Ewertsen, Caroline; Săftoiu, Adrian; Gruionu, Lucian G

    2013-01-01

    The aim of our article is to give an overview of the current and future possibilities of real-time image fusion involving ultrasound. We present a review of the existing English-language peer-reviewed literature assessing this technique, which covers technical solutions (for ultrasound and endosc...

  12. Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions.

    Science.gov (United States)

    Halldorsdottir, Valgerdur G; Dave, Jaydev K; Leodore, Lauren M; Eisenbrey, John R; Park, Suhyun; Hall, Anne L; Thomenius, Kai; Forsberg, Flemming

    2011-07-01

    Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled confocally at a 60 degree angle to each other. Changes in the first, second and subharmonic amplitudes of five different ultrasound contrast agents were measured in vitro at static hydrostatic pressures from 0-186 mmHg, acoustic pressures from 0.35-0.60 MPa peak-to-peak and frequencies of 2.5-6.6 MHz. The most sensitive agent and optimal parameters for SHAPE were determined using linear regression analysis and implemented on a Logiq 9 scanner (GE Healthcare, Milwaukee, WI). This implementation of SHAPE was then tested under dynamic-flow conditions and compared to pressure-catheter measurements. Over the pressure range studied, the first and second harmonic amplitudes reduced approximately 2 dB for all contrast agents. Over the same pressure range, the subharmonic amplitudes decreased by 9-14 dB and excellent linear regressions were achieved with the hydrostatic pressure variations (r = 0.98, p < 0.001). Optimal sensitivity was achieved at a transmit frequency of 2.5 MHz and acoustic pressure of 0.35 MPa using Sonazoid (GE Healthcare, Oslo, Norway). A Logiq 9 scanner was modified to implement SHAPE on a convex transducer with a frequency range from 1.5-4.5 MHz and acoustic pressures from 0-3.34 MPa. Results matched the pressure catheter (r2 = 0.87). In conclusion, subharmonic contrast signals are a good indicator of hydrostatic pressure. Out of the five ultrasound contrast agents tested, Sonazoid was the most sensitive for subharmonic pressure estimation. Real-time SHAPE has been implemented on a commercial scanner and offers the possibility of allowing pressures in the heart and elsewhere to be obtained noninvasively.

  13. Research interface for experimental ultrasound imaging - the CFU grabber project

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Hemmsen, Martin Christian; Jensen, Jørgen Arendt

    Purpose The acquisition of ultrasound images using new calculation methods usually requires days of post processing. An ultrasound scanner with a research interface developed in collaboration between DTU and BK medicals has made it possible to process US images faster than the current reaserch...... system RASMUS. Furthermore precise scanner settings are stored for inter- and intra-observer studies. The resulting images are used for clinical evaluation. Method and materials The ultrasound scanners research interface is connected to a graphical grabber card in a Windows PC (Grabber PC). The grabber......) was performed. The resulting 3 seconds of image sequences (video) will be evaluated by experts within medical ultrasound imaging. Conclusion The setup makes the data aquisition fast and the scanner setting reproducible and the first in-vivo studies using the new research system are on-going....

  14. Proceedings: Beyond Ultrasound First Forum on improving the quality of ultrasound imaging in obstetrics and gynecology.

    Science.gov (United States)

    Benacerraf, Beryl R; Minton, Katherine K; Benson, Carol B; Bromley, Bryann S; Coley, Brian D; Doubilet, Peter M; Lee, Wesley; Maslak, Samuel H; Pellerito, John S; Perez, James J; Savitsky, Eric; Scarborough, Norman A; Wax, Joseph; Abuhamad, Alfred Z

    2018-01-01

    The Beyond Ultrasound First Forum was conceived to increase awareness that the quality of obstetric and gynecologic ultrasound can be improved, and is inconsistent throughout the country, likely due to multiple factors, including the lack of a standardized curriculum and competency assessment in ultrasound teaching. The forum brought together representatives from many professional associations; the imaging community including radiology, obstetrics and gynecology, and emergency medicine among others; in addition to government agencies, insurers, industry, and others with common interest in obstetric and gynecologic ultrasound. This group worked together in focus sessions aimed at developing solutions on how to standardize and improve ultrasound training at the resident level and beyond. A new curriculum and competency assessment program for teaching residents (obstetrics and gynecology, radiology, and any other specialty doing obstetrics and gynecology ultrasound) was presented, and performance measures of ultrasound quality in clinical practice were discussed. The aim of this forum was to increase and unify the quality of ultrasound examinations in obstetrics and gynecology with the ultimate goal of improving patient safety and quality of clinical care. This report describes the proceedings of this conference including possible approaches to resident teaching and means to improve the inconsistent quality of ultrasound examinations performed today. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Beef quality parameters estimation using ultrasound and color images

    National Research Council Canada - National Science Library

    Nunes, Jose; Piquerez, Martín; Pujadas, Leonardo; Armstrong, Eileen; Fernández, Alicia; Lecumberry, Federico

    2015-01-01

    .... In this paper we set out to obtain beef quality estimates from the analysis of ultrasound (in vivo) and color images (post mortem), with the measurement of various parameters related to tenderness and amount of meat...

  16. Rehabilitative ultrasound imaging of the posterior paraspinal muscles

    National Research Council Canada - National Science Library

    Stokes, Maria; Hides, Julie; Elliott, James; Kiesel, Kyle; Hodges, Paul

    2007-01-01

    Interest in rehabilitative ultrasound imaging (RUSI) of the posterior paraspinal muscles is growing, along with the body of literature to support integration of this technique into routine physical therapy practice...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves ... the limitations of Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to ... Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces pictures ...

  19. Elastic-net based beamforming in medical ultrasound imaging

    OpenAIRE

    Szasz, Teodora; Basarab, Adrian; Vaida, Mircea-Florin; Kouamé, Denis

    2016-01-01

    International audience; This paper presents a new way of addressing beamforming in ultrasound imaging, by formulating it, for each image depth, as an inverse problem solved using elastic-net regularization. This approach was evaluated on both simulated and in vivo data showing a gain in contrast, while maintaining an increased value of the signal-to-noise ratio compared to two standard ultrasound beamforming methods.

  20. Ultrasound Vector Flow Imaging: Part II: Parallel Systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav Ivanov; Yu, Alfred C. H.

    2016-01-01

    The paper gives a review of the current state-of-theart in ultrasound parallel acquisition systems for flow imaging using spherical and plane waves emissions. The imaging methods are explained along with the advantages of using these very fast and sensitive velocity estimators. These experimental...... ultrasound imaging for studying brain function in animals. The paper explains the underlying acquisition and estimation methods for fast 2-D and 3-D velocity imaging and gives a number of examples. Future challenges and the potentials of parallel acquisition systems for flow imaging are also discussed....

  1. Assessment of Kidney Volume Measurement Techniques for Ultrasound Images

    OpenAIRE

    Wan Mahani Hafizah Wan Mahmud; Eko Supriyanto

    2015-01-01

    This study intends to assess and compare the accuracy of different methods for estimating the kidney volume of ultrasound images consist of volume measurement from length-based, area-based and surface-based. For length-based method, the ellipsoid formula was used and for surface-based method, the volume can be automatically obtained from 3D ultrasound system after some manual contouring. For area-based method, sets of ultrasound images with different number of slices were used. After manual c...

  2. Spatial Angular Compounding Technique for H-Scan Ultrasound Imaging.

    Science.gov (United States)

    Khairalseed, Mawia; Xiong, Fangyuan; Kim, Jung-Whan; Mattrey, Robert F; Parker, Kevin J; Hoyt, Kenneth

    2017-10-11

    H-Scan is a new ultrasound imaging technique that relies on matching a model of pulse-echo formation to the mathematics of a class of Gaussian-weighted Hermite polynomials. This technique may be beneficial in the measurement of relative scatterer sizes and in cancer therapy, particularly for early response to drug treatment. Because current H-scan techniques use focused ultrasound data acquisitions, spatial resolution degrades away from the focal region and inherently affects relative scatterer size estimation. Although the resolution of ultrasound plane wave imaging can be inferior to that of traditional focused ultrasound approaches, the former exhibits a homogeneous spatial resolution throughout the image plane. The purpose of this study was to implement H-scan using plane wave imaging and investigate the impact of spatial angular compounding on H-scan image quality. Parallel convolution filters using two different Gaussian-weighted Hermite polynomials that describe ultrasound scattering events are applied to the radiofrequency data. The H-scan processing is done on each radiofrequency image plane before averaging to get the angular compounded image. The relative strength from each convolution is color-coded to represent relative scatterer size. Given results from a series of phantom materials, H-scan imaging with spatial angular compounding more accurately reflects the true scatterer size caused by reductions in the system point spread function and improved signal-to-noise ratio. Preliminary in vivo H-scan imaging of tumor-bearing animals suggests this modality may be useful for monitoring early response to chemotherapeutic treatment. Overall, H-scan imaging using ultrasound plane waves and spatial angular compounding is a promising approach for visualizing the relative size and distribution of acoustic scattering sources. Copyright © 2017 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  3. Ovarian ultrasound image analysis: follicle segmentation.

    Science.gov (United States)

    Krivanek, A; Sonka, M

    1998-12-01

    Ovarian ultrasound is an effective tool in infertility treatment. Repeated measurements of the size and shape of follicles over several days are the primary means of evaluation by physicians. Currently, follicle wall segmentation is achieved by manual tracing which is time consuming and susceptible to inter-operator variation. An automated method for follicle wall segmentation is reported that uses a four-step process based on watershed segmentation and knowledge-based graph search algorithm which utilizes priori information about follicle structure for inner and outer wall detection. The automated technique was tested on 36 ultrasonographic images of women's ovaries. Validation against manually traced borders has shown good correlation of manually defined and computer-determined area measurements (R2 = 0.85 - 0.96). The border positioning errors were small: 0.63+/-0.36 mm for inner border and 0.67+/-0.41 mm for outer border detection. The use of watershed segmentation and graph search methods facilitates fast, accurate inner and outer border detection with minimal user-interaction.

  4. Ultrasound contrast-agent improves imaging of lower limb occlusive disease

    DEFF Research Database (Denmark)

    Eiberg, J P; Hansen, M A; Jensen, F

    2003-01-01

    to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA)....

  5. An Axial Array for Volumetric Intravascular Ultrasound Imaging

    NARCIS (Netherlands)

    Alles, E.J.

    2012-01-01

    Intravascular ultrasound (IVUS) is a medical imaging modality aimed at imaging blood vessel walls from within the vessel. Current commercial IVUS catheters are designed to yield two-dimensional cross-sectional images perpendicular to the vessel wall. By pulling the catheter back through the artery

  6. Application of reinforcement learning for segmentation of transrectal ultrasound images.

    Science.gov (United States)

    Sahba, Farhang; Tizhoosh, Hamid R; Salama, Magdy M A

    2008-04-22

    Among different medical image modalities, ultrasound imaging has a very widespread clinical use. But, due to some factors, such as poor image contrast, noise and missing or diffuse boundaries, the ultrasound images are inherently difficult to segment. An important application is estimation of the location and volume of the prostate in transrectal ultrasound (TRUS) images. For this purpose, manual segmentation is a tedious and time consuming procedure. We introduce a new method for the segmentation of the prostate in transrectal ultrasound images, using a reinforcement learning scheme. This algorithm is used to find the appropriate local values for sub-images and to extract the prostate. It contains an offline stage, where the reinforcement learning agent uses some images and manually segmented versions of these images to learn from. The reinforcement agent is provided with reward/punishment, determined objectively to explore/exploit the solution space. After this stage, the agent has acquired knowledge stored in the Q-matrix. The agent can then use this knowledge for new input images to extract a coarse version of the prostate. We have carried out experiments to segment TRUS images. The results demonstrate the potential of this approach in the field of medical image segmentation. By using the proposed method, we can find the appropriate local values and segment the prostate. This approach can be used for segmentation tasks containing one object of interest. To improve this prototype, more investigations are needed.

  7. Application of reinforcement learning for segmentation of transrectal ultrasound images

    Directory of Open Access Journals (Sweden)

    Tizhoosh Hamid R

    2008-04-01

    Full Text Available Abstract Background Among different medical image modalities, ultrasound imaging has a very widespread clinical use. But, due to some factors, such as poor image contrast, noise and missing or diffuse boundaries, the ultrasound images are inherently difficult to segment. An important application is estimation of the location and volume of the prostate in transrectal ultrasound (TRUS images. For this purpose, manual segmentation is a tedious and time consuming procedure. Methods We introduce a new method for the segmentation of the prostate in transrectal ultrasound images, using a reinforcement learning scheme. This algorithm is used to find the appropriate local values for sub-images and to extract the prostate. It contains an offline stage, where the reinforcement learning agent uses some images and manually segmented versions of these images to learn from. The reinforcement agent is provided with reward/punishment, determined objectively to explore/exploit the solution space. After this stage, the agent has acquired knowledge stored in the Q-matrix. The agent can then use this knowledge for new input images to extract a coarse version of the prostate. Results We have carried out experiments to segment TRUS images. The results demonstrate the potential of this approach in the field of medical image segmentation. Conclusion By using the proposed method, we can find the appropriate local values and segment the prostate. This approach can be used for segmentation tasks containing one object of interest. To improve this prototype, more investigations are needed.

  8. Needle tip visibility in 3D ultrasound images

    Science.gov (United States)

    Arif, Muhammad; Moelker, Adriaan; van Walsum, Theo

    2017-03-01

    Needle visibility is of crucial importance for ultrasound guided interventional procedures. However, several factors, such as shadowing by bone or gas and tissue echogenic properties similar to needles, may compromise needle visibility. Additionally, small angle between the ultrasound beam and the needle, as well as small gauged needles may reduce visibility. Variety in needle tips design may also affect needle visibility. Whereas several studies have investigated needle visibility in 2D ultrasound imaging, no data is available for 3D ultrasound imaging, a modality that has great potential for image guidance interventions1. In this study, we evaluated needle visibility using a 3D ultrasound transducer. We examined different needles in a tissue mimicking liver phantom at three angles (200, 550 and 900) and quantify their visibility. The liver phantom was made by 5% polyvinyl alcohol solution containing 1% Silica gel particles to act as ultrasound scattering particles. We used four needles; two biopsy needles (Quick core 14G and 18G), one Ablation needle (Radiofrequency Ablation 17G), and Initial puncture needle (IP needle 17G). The needle visibility was quantified by calculating contrast to noise ratio. The results showed that the visibility for all needles were almost similar at large angles. However the difference in visibility at lower angles is more prominent. Furthermore, the visibility increases with the increase in angle of ultrasound beam with needles.

  9. Ultrasound artifacts: classification, applied physics with illustrations, and imaging appearances.

    Science.gov (United States)

    Prabhu, Somnath J; Kanal, Kalpana; Bhargava, Puneet; Vaidya, Sandeep; Dighe, Manjiri K

    2014-06-01

    Ultrasound has become a widely used diagnostic imaging modality in medicine because of its safety and portability. Because of rapid advances in technology, in recent years, sonographic imaging quality has significantly increased. Despite these advances, the potential to encounter artifacts while imaging remains.This article classifies both common and uncommon gray-scale and Doppler ultrasound artifacts into those resulting from physiology and those caused by hardware. A brief applied-physics explanation for each artifact is listed along with an illustrated diagram. The imaging appearance of artifacts is presented in case examples, along with strategies to minimize the artifacts in real time or use them for clinical advantage where applicable.

  10. Extracting cardiac myofiber orientations from high frequency ultrasound images

    Science.gov (United States)

    Qin, Xulei; Cong, Zhibin; Jiang, Rong; Shen, Ming; Wagner, Mary B.; Kirshbom, Paul; Fei, Baowei

    2013-03-01

    Cardiac myofiber plays an important role in stress mechanism during heart beating periods. The orientation of myofibers decides the effects of the stress distribution and the whole heart deformation. It is important to image and quantitatively extract these orientations for understanding the cardiac physiological and pathological mechanism and for diagnosis of chronic diseases. Ultrasound has been wildly used in cardiac diagnosis because of its ability of performing dynamic and noninvasive imaging and because of its low cost. An extraction method is proposed to automatically detect the cardiac myofiber orientations from high frequency ultrasound images. First, heart walls containing myofibers are imaged by B-mode high frequency (pig hearts.

  11. Multispectral photoacoustic imaging of nerves with a clinical ultrasound system

    Science.gov (United States)

    Mari, Jean Martial; West, Simeon; Beard, Paul C.; Desjardins, Adrien E.

    2014-03-01

    Accurate and efficient identification of nerves is of great importance during many ultrasound-guided clinical procedures, including nerve blocks and prostate biopsies. It can be challenging to visualise nerves with conventional ultrasound imaging, however. One of the challenges is that nerves can have very similar appearances to nearby structures such as tendons. Several recent studies have highlighted the potential of near-infrared optical spectroscopy for differentiating nerves and adjacent tissues, as this modality can be sensitive to optical absorption of lipids that are present in intra- and extra-neural adipose tissue and in the myelin sheaths. These studies were limited to point measurements, however. In this pilot study, a custom photoacoustic system with a clinical ultrasound imaging probe was used to acquire multi-spectral photoacoustic images of nerves and tendons from swine ex vivo, across the wavelength range of 1100 to 1300 nm. Photoacoustic images were processed and overlaid in colour onto co-registered conventional ultrasound images that were acquired with the same imaging probe. A pronounced optical absorption peak centred at 1210 nm was observed in the photoacoustic signals obtained from nerves, and it was absent in those obtained from tendons. This absorption peak, which is consistent with the presence of lipids, provides a novel image contrast mechanism to significantly enhance the visualization of nerves. In particular, image contrast for nerves was up to 5.5 times greater with photoacoustic imaging (0.82 +/- 0.15) than with conventional ultrasound imaging (0.148 +/- 0.002), with a maximum contrast of 0.95 +/- 0.02 obtained in photoacoustic mode. This pilot study demonstrates the potential of photoacoustic imaging to improve clinical outcomes in ultrasound-guided interventions in regional anaesthesia and interventional oncology.

  12. Fast ultrasound imaging simulation in K-space.

    Science.gov (United States)

    Hergum, Torbjørn; Langeland, Stian; Remme, Espen W; Torp, Hans

    2009-06-01

    Most available ultrasound imaging simulation methods are based on the spatial impulse response approach. The execution speed of such a simulation is of the order of days for one heart-sized frame using desktop computers. For some applications, the accuracy of such rigorous simulation approaches is not necessary. This work outlines a much faster 3-D ultrasound imaging simulation approach that can be applied to tasks like simulating 3-D ultrasound images for speckletracking. The increased speed of the proposed simulation method is based primarily on the approximation that the point spread function is set to be spatially invariant, which is a reasonably good approximation when using polar coordinates for simulating images from phased arrays with constant aperture. Ultrasound images are found as the convolution of the PSF and an object of sparsely distributed scatterers. The scatterers are passed through an anti-aliasing filter before insertion into a regular beam-space grid to reduce the bandwidth and significantly reduce the amount of data. A comparison with the well-established simulation software package Field II has been made. A simulation of a cyst image using the same input object was found to be in the order of 7000 times slower than the presented method. Following these considerations, the proposed simulation method can be a rapid and valuable tool for working with 3-D ultrasound imaging and in particular 3-D speckle-tracking.

  13. In Vivo Real Time Volumetric Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Rasmussen, Morten Fischer; Brandt, Andreas Hjelm

    2015-01-01

    Synthetic aperture (SA) imaging can be used to achieve real-time volumetric ultrasound imaging using 2-D array transducers. The sensitivity of SA imaging is improved by maximizing the acoustic output, but one must consider the limitations of an ultrasound system, both technical and biological....... This paper investigates the in vivo applicability and sensitivity of volumetric SA imaging. Utilizing the transmit events to generate a set of virtual point sources, a frame rate of 25 Hz for a 90° x 90° field-of-view was achieved. Data were obtained using a 3.5 MHz 32 x 32 elements 2-D phased array...... transducer connected to the experimental scanner (SARUS). Proper scaling is applied to the excitation signal such that intensity levels are in compliance with the U.S. Food and Drug Administration regulations for in vivo ultrasound imaging. The measured Mechanical Index and spatial-peak- temporal...

  14. Duplex/doppler ultrasound test (image)

    Science.gov (United States)

    The duplex/doppler ultrasound test examines the blood flow in the major arteries and veins in the arms and legs. The ... duplex ultrasonagraphy to visualize the blood flow and doppler ultrasonagraphy provides an audio means to hear the ...

  15. Integration of ultrasound imaging into pre-clinical dental education.

    Science.gov (United States)

    Kondrashova, T; De Wan, D; Briones, M U; Kondrashov, P

    2017-11-01

    Patients have complex healthcare needs and typically require more than one healthcare discipline to address issues regarding their health. Interprofessional teams of healthcare professionals may be able to address these complex needs and improve patient outcomes by combining resources. To evaluate the feasibility of integrating ultrasound into a dental school curriculum to teach anatomy as part of an interprofessional education experience, the current study surveyed first-year dental students to determine their perceptions of the integration of ultrasound techniques into the curriculum. Ultrasound laboratory exercises were developed for first-year dental students as part of their anatomy course. The exercises were focused on head, neck and abdominal anatomy. To assess student perception of the integration of ultrasound into the dental curriculum, a survey was created specifically for the current study. Between 2013 and 2015, two classes of first-year dental students participated in the ultrasound laboratory exercise and completed the survey (n = 83). Student survey responses suggested ultrasound was a valuable teaching tool because it allowed them to visualise anatomical structures using live imaging. They also agreed that the ultrasound laboratory exercises were an efficient learning tool, but the majority did not believe that they would use ultrasound regularly in their future practice. Results of the current study suggested first-year dental students were satisfied with the integration of ultrasound techniques into the dental curriculum. Survey results indicated that the students enjoyed the ultrasound laboratory exercise and felt ultrasound was an effective learning tool. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Application of molecular ultrasound for imaging integrin expression.

    Science.gov (United States)

    Kiessling, Fabian; Gaetjens, Jessica; Palmowski, Moritz

    2011-02-01

    Stabilized microbubbles with a size between 1-5 µm are used as ultrasound contrast agents in the clinical routine. They have shown convincing results for the vascular characterization of tissues as well as in echocardiography. Due to their size, microbubbles strictly remain intravascular where they can be detected with high sensitivity and specificity. This qualifies them for intravascular molecular imaging. Many studies have been published reporting on the successful use of microbubbles conjugated to specific ligands for target identification in vivo. Among them, there are several promising examples on how to use molecular ultrasound for the imaging of integrin expression. This review provides an overview on the composition of ultrasound contrast agents that can be used for molecular imaging and their detection by ultrasound using destructive and non destructive methods. Furthermore, concrete examples are given on the use of molecular ultrasound to characterize integrin expression on vessels. These cover oncological applications where integrin targeted microbubbles were used to identify and characterize tumor angiogenesis and to assess tumor response to antiangiogenic drugs as well as to radiotherapy. In addition, increased accumulation of integrin targeted microbubbles was found during vascular reformation in ischemic tissues as well as in vulnerable atherosclerotic plaques. In summary, there is clear evidence from preclinical studies that integrin targeted ultrasound imaging is a valuable tool for the characterization of a broad spectrum of diseases. Thus, more efforts should be put into translating this promising technology into the clinics.

  17. Tumor functional and molecular imaging utilizing ultrasound and ultrasound-mediated optical techniques.

    Science.gov (United States)

    Yuan, Baohong; Rychak, Joshua

    2013-02-01

    Tumor functional and molecular imaging has significantly contributed to cancer preclinical research and clinical applications. Among typical imaging modalities, ultrasonic and optical techniques are two commonly used methods; both share several common features such as cost efficiency, absence of ionizing radiation, relatively inexpensive contrast agents, and comparable maximum-imaging depth. Ultrasonic and optical techniques are also complementary in imaging resolution, molecular sensitivity, and imaging space (vascular and extravascular). The marriage between ultrasonic and optical techniques takes advantages of both techniques. This review introduces tumor functional and molecular imaging using microbubble-based ultrasound and ultrasound-mediated optical imaging techniques. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  18. Standardized ultrasound templates for diagnosing appendicitis reduce annual imaging costs.

    Science.gov (United States)

    Nordin, Andrew B; Sales, Stephen; Nielsen, Jason W; Adler, Brent; Bates, David Gregory; Kenney, Brian

    2018-01-01

    Ultrasound is preferred over computed tomography (CT) for diagnosing appendicitis in children to avoid undue radiation exposure. We previously reported our experience in instituting a standardized appendicitis ultrasound template, which decreased CT rates by 67.3%. In this analysis, we demonstrate the ongoing cost savings associated with using this template. Retrospective chart review for the time period preceding template implementation (June 2012-September 2012) was combined with prospective review through December 2015 for all patients in the emergency department receiving diagnostic imaging for appendicitis. The type of imaging was recorded, and imaging rates and ultrasound test statistics were calculated. Estimated annual imaging costs based on pretemplate ultrasound and CT utilization rates were compared with post-template annual costs to calculate annual and cumulative savings. In the pretemplate period, ultrasound and CT rates were 80.2% and 44.3%, respectively, resulting in a combined annual cost of $300,527.70. Similar calculations were performed for each succeeding year, accounting for changes in patient volume. Using pretemplate rates, our projected 2015 imaging cost was $371,402.86; however, our ultrasound rate had increased to 98.3%, whereas the CT rate declined to 9.6%, yielding an annual estimated cost of $224,853.00 and a savings of $146,549.86. Since implementation, annual savings have steadily increased for a cumulative cost savings of $336,683.83. Standardizing ultrasound reports for appendicitis not only reduces the use of CT scans and the associated radiation exposure but also decreases annual imaging costs despite increased numbers of imaging studies. Continued cost reduction may be possible by using diagnostic algorithms. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. An Assessment of Iterative Reconstruction Methods for Sparse Ultrasound Imaging.

    Science.gov (United States)

    Valente, Solivan A; Zibetti, Marcelo V W; Pipa, Daniel R; Maia, Joaquim M; Schneider, Fabio K

    2017-03-08

    Ultrasonic image reconstruction using inverse problems has recently appeared as an alternative to enhance ultrasound imaging over beamforming methods. This approach depends on the accuracy of the acquisition model used to represent transducers, reflectivity, and medium physics. Iterative methods, well known in general sparse signal reconstruction, are also suited for imaging. In this paper, a discrete acquisition model is assessed by solving a linear system of equations by an ℓ 1 -regularized least-squares minimization, where the solution sparsity may be adjusted as desired. The paper surveys 11 variants of four well-known algorithms for sparse reconstruction, and assesses their optimization parameters with the goal of finding the best approach for iterative ultrasound imaging. The strategy for the model evaluation consists of using two distinct datasets. We first generate data from a synthetic phantom that mimics real targets inside a professional ultrasound phantom device. This dataset is contaminated with Gaussian noise with an estimated SNR, and all methods are assessed by their resulting images and performances. The model and methods are then assessed with real data collected by a research ultrasound platform when scanning the same phantom device, and results are compared with beamforming. A distinct real dataset is finally used to further validate the proposed modeling. Although high computational effort is required by iterative methods, results show that the discrete model may lead to images closer to ground-truth than traditional beamforming. However, computing capabilities of current platforms need to evolve before frame rates currently delivered by ultrasound equipments are achievable.

  20. Compact Beamformer Design with High Frame Rate for Ultrasound Imaging

    Directory of Open Access Journals (Sweden)

    Jun Luo

    2014-04-01

    Full Text Available In medical field, two-dimension ultrasound images are widely used in clinical diagnosis. Beamformer is critical in determining the complexity and performance of an ultrasound imaging system. Different from traditional means implemented with separated chips, a compact beamformer with 64 effective channels in a single moderate Field Programmable Gate Array has been presented in this paper. The compactness is acquired by employing receive synthetic aperture, harmonic imaging, time sharing and linear interpolation. Besides that, multi-beams method is used to improve the frame rate of the ultrasound imaging system. Online dynamic configuration is employed to expand system’s flexibility to two kinds of transducers with multi-scanning modes. The design is verified on a prototype scanner board. Simulation results have shown that on-chip memories can be saved and the frame rate can be improved on the case of 64 effective channels which will meet the requirement of real-time application.

  1. Experimental ultrasound system for real-time synthetic imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Holm, Ole; Jensen, Lars Joost

    1999-01-01

    Digital signal processing is being employed more and more in modern ultrasound scanners. This has made it possible to do dynamic receive focusing for each sample and implement other advanced imaging methods. The processing, however, has to be very fast and cost-effective at the same time. Dedicated......-element ultrasound transducers, and to enable real-time or near realtime processing of the acquired data. The system will be capable of performing the processing for the currently available imaging methods, and will make it possible to perform initial trials in a clinical environment with new imaging modalities...

  2. Quantitative Nonlinear Contrast-Enhanced Ultrasound of the Breast.

    Science.gov (United States)

    Sridharan, Anush; Eisenbrey, John R; Dave, Jaydev K; Forsberg, Flemming

    2016-08-01

    Breast cancer is the most frequent type of cancer among women (25% of all cancers). The angiogenic process that fuels the growth of tumors is a potential early indicator for differentiating between malignant and benign tumors. Recently, the use of microbubble-based contrast agents combined with ultrasound has allowed the development of contrast agent-specific imaging modes that provide visualization of tumor neovascularity. Contrast-enhanced Doppler, harmonic, and subharmonic imaging are some of the imaging modes that have been investigated for visualizing and quantifying the vascularity in breast tumors.

  3. Integrated photoacoustic/ultrasound imaging: applications and new techniques

    NARCIS (Netherlands)

    van den Berg, P.J.

    2017-01-01

    Photoacoustic imaging (PAI) is a unique combination of optical sensitivity to tissue chromophores like hemoglobin, and ultrasonic resolution. Research in this PhD thesis is made possible by the development of a probe that combines PAI with regular ultrasound imaging. This probe is handheld and

  4. Implementation of Synthetic Aperture Imaging in Medical Ultrasound

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Kortbek, Jacob; Nikolov, Svetoslav

    2010-01-01

    The main advantage of medical ultrasound imaging is its real time capability, which makes it possible to visualize dynamic structures in the human body. Real time synthetic aperture imaging puts very high demands on the hardware, which currently cannot be met. A method for reducing the number of ...

  5. State of the art cranial ultrasound imaging in neonates

    NARCIS (Netherlands)

    Ecury-Goossen, Ginette M; Camfferman, Fleur A; Leijser, Lara M; Govaert, Paul; Dudink, Jeroen

    2015-01-01

    Cranial ultrasound (CUS) is a reputable tool for brain imaging in critically ill neonates. It is safe, relatively cheap and easy to use, even when a patient is unstable. In addition it is radiation-free and allows serial imaging. CUS possibilities have steadily expanded. However, in many neonatal

  6. Multimodality ultrasound imaging in stroke: current concepts and future focus.

    Science.gov (United States)

    Liu, Yumei; Hua, Yang; Feng, Wuwei; Ovbiagele, Bruce

    2016-12-01

    Stroke is a leading cause of disability and mortality worldwide. Ultrasound is a real-time imaging technique that is inexpensive, portable, non-invasive, and safe, with high diagnostic accuracy. Ultrasonic imaging can provide useful direct and indirect information about the characteristics of various vessels in the both intracranial and extracranial segments. Areas covered: In this review, we will discuss multimodal applications of ultrasonic imaging in stroke prevention and management including checking carotid intima-media thickness progression, evaluating the plaque morphology, calibrating the degree of stenosis, detecting the presence of patent foramen ovale, monitoring microembolization, and screening for stroke risk in patients with sickle cell disease. We present the conventional ultrasonography as well as the novel ultrasound techniques including gray scale median, 3-dementional ultrasound, elastography, intravascular ultrasound, and contrast-enhanced ultrasound. Expert commentary: Ultrasonography is a non-invasive, low-cost, safe, fast, and real-time imaging technology for stroke risk assessment. Each modality has its own advantage as well as limitation. Future research should be focused on developing new technologies that can improve the quality of imaging and accuracy of diagnosis.

  7. Real-time kidney ultrasound image segmentation: a prospective study

    Science.gov (United States)

    Dahdouh, S.; Frenoux, E.; Osorio, A.

    2009-02-01

    Segmentation of ultrasound kidney images represents a challenge due to low quality data. Speckle, shadows, signal dropout and low contrast make segmentation a harsh task. In addition, kidney ultrasound imaging presents a great variability concerning the organ's shape on the image. This characteristic makes learning methods hard to use. The aim of this study is to develop a real time kidney ultrasound image segmentation method usable during surgical operations such as punctures. To deal with real time constraints, we decided to focus on region based methods and particularly split and merge algorithm. In this prospective study, the selection of the interesting area in the initial image is made by the physician, drawing a coarse bounding box around the organ. A pre-processing phase is first performed to correct image's artefacts. This phase is composed of three major steps. First, an image specification is made between the image to segment and a reference one. Then, a Haar wavelet filtering method is applied on the resulting image and finally an anisotropic diffusion filter is applied to smooth the result. Then, a split and merge algorithm is applied on the resulting image. Both split and merge criteria are based on regions statistics. Our method has been successfully applied on a set of 22 clinical images coming from 10 different patients and presenting different points of view regarding kidney's shape. We obtained very good results, for an average computational time of 8.5 seconds per image.

  8. Calibration and Evaluation of Ultrasound Thermography using Infrared Imaging

    Science.gov (United States)

    Hsiao, Yi-Sing; Deng, Cheri X.

    2015-01-01

    Real-time monitoring of the spatiotemporal evolution of tissue temperature is important to ensure safe and effective treatment in thermal therapies including hyperthermia and thermal ablation. Ultrasound thermography has been proposed as a non-invasive technique for temperature measurement, and accurate calibration of the temperature-dependent ultrasound signal changes against temperature is required. Here we report a method that uses infrared (IR) thermography for calibration and validation of ultrasound thermography. Using phantoms and cardiac tissue specimens subjected to high-intensity focused ultrasound (HIFU) heating, we simultaneously acquired ultrasound and IR imaging data from the same surface plane of a sample. The commonly used echo time shift-based method was chosen to compute ultrasound thermometry. We first correlated the ultrasound echo time shifts with IR-measured temperatures for material-dependent calibration and found that the calibration coefficient was positive for fat-mimicking phantom (1.49 ± 0.27) but negative for tissue-mimicking phantom (− 0.59 ± 0.08) and cardiac tissue (− 0.69 ± 0.18 °C-mm/ns). We then obtained the estimation error of the ultrasound thermometry by comparing against the IR measured temperature and revealed that the error increased with decreased size of the heated region. Consistent with previous findings, the echo time shifts were no longer linearly dependent on temperature beyond 45 – 50 °C in cardiac tissues. Unlike previous studies where thermocouples or water-bath techniques were used to evaluate the performance of ultrasound thermography, our results show that high resolution IR thermography provides a useful tool that can be applied to evaluate and understand the limitations of ultrasound thermography methods. PMID:26547634

  9. Ultrasound contrast-agent improves imaging of lower limb occlusive disease

    DEFF Research Database (Denmark)

    Eiberg, J P; Hansen, M A; Jensen, F

    2003-01-01

    to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA).......to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA)....

  10. Subharmonic resonances of the parametrically driven pendulum

    Science.gov (United States)

    Butikov, Eugene I.

    2002-08-01

    A simple qualitative physical explanation is suggested for the phenomenon of subharmonic resonances of a rigid planar pendulum whose axis is forced to oscillate with a high frequency in the vertical direction. An approximate quantitative theory based on the suggested approach is developed. The spectral composition of the subharmonic resonances is investigated quantitatively, and the boundaries of these modes in the parameter space are determined. New related modes of regular behaviour are described and explained. The conditions of the inverted pendulum stability are determined with greater precision than previous results. A computer program simulating the physical system supports the analytical investigation.

  11. Ultrasound imaging beyond the vasculature with new generation contrast agents.

    Science.gov (United States)

    Perera, Reshani H; Hernandez, Christopher; Zhou, Haoyan; Kota, Pavan; Burke, Alan; Exner, Agata A

    2015-01-01

    Current commercially available ultrasound contrast agents are gas-filled, lipid- or protein-stabilized microbubbles larger than 1 µm in diameter. Because the signal generated by these agents is highly dependent on their size, small yet highly echogenic particles have been historically difficult to produce. This has limited the molecular imaging applications of ultrasound to the blood pool. In the area of cancer imaging, microbubble applications have been constrained to imaging molecular signatures of tumor vasculature and drug delivery enabled by ultrasound-modulated bubble destruction. Recently, with the rise of sophisticated advancements in nanomedicine, ultrasound contrast agents, which are an order of magnitude smaller (100-500 nm) than their currently utilized counterparts, have been undergoing rapid development. These agents are poised to greatly expand the capabilities of ultrasound in the field of targeted cancer detection and therapy by taking advantage of the enhanced permeability and retention phenomenon of many tumors and can extravasate beyond the leaky tumor vasculature. Agent extravasation facilitates highly sensitive detection of cell surface or microenvironment biomarkers, which could advance early cancer detection. Likewise, when combined with appropriate therapeutic agents and ultrasound-mediated deployment on demand, directly at the tumor site, these nanoparticles have been shown to contribute to improved therapeutic outcomes. Ultrasound's safety profile, broad accessibility and relatively low cost make it an ideal modality for the changing face of healthcare today. Aided by the multifaceted nano-sized contrast agents and targeted theranostic moieties described herein, ultrasound can considerably broaden its reach in future applications focused on the diagnosis and staging of cancer. © 2015 Wiley Periodicals, Inc.

  12. Rayleigh-maximum-likelihood bilateral filter for ultrasound image enhancement.

    Science.gov (United States)

    Li, Haiyan; Wu, Jun; Miao, Aimin; Yu, Pengfei; Chen, Jianhua; Zhang, Yufeng

    2017-04-17

    Ultrasound imaging plays an important role in computer diagnosis since it is non-invasive and cost-effective. However, ultrasound images are inevitably contaminated by noise and speckle during acquisition. Noise and speckle directly impact the physician to interpret the images and decrease the accuracy in clinical diagnosis. Denoising method is an important component to enhance the quality of ultrasound images; however, several limitations discourage the results because current denoising methods can remove noise while ignoring the statistical characteristics of speckle and thus undermining the effectiveness of despeckling, or vice versa. In addition, most existing algorithms do not identify noise, speckle or edge before removing noise or speckle, and thus they reduce noise and speckle while blurring edge details. Therefore, it is a challenging issue for the traditional methods to effectively remove noise and speckle in ultrasound images while preserving edge details. To overcome the above-mentioned limitations, a novel method, called Rayleigh-maximum-likelihood switching bilateral filter (RSBF) is proposed to enhance ultrasound images by two steps: noise, speckle and edge detection followed by filtering. Firstly, a sorted quadrant median vector scheme is utilized to calculate the reference median in a filtering window in comparison with the central pixel to classify the target pixel as noise, speckle or noise-free. Subsequently, the noise is removed by a bilateral filter and the speckle is suppressed by a Rayleigh-maximum-likelihood filter while the noise-free pixels are kept unchanged. To quantitatively evaluate the performance of the proposed method, synthetic ultrasound images contaminated by speckle are simulated by using the speckle model that is subjected to Rayleigh distribution. Thereafter, the corrupted synthetic images are generated by the original image multiplied with the Rayleigh distributed speckle of various signal to noise ratio (SNR) levels and

  13. Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

    Energy Technology Data Exchange (ETDEWEB)

    Demi, Libertario, E-mail: l.demi@tue.nl; Sloun, Ruud J. G. van; Mischi, Massimo [Lab. of Biomedical Diagnostics, Dept. of Electrical Eng., Eindhoven University of Technology (Netherlands); Wijkstra, Hessel [Lab. of Biomedical Diagnostics, Dept. of Electrical Eng., Eindhoven University of Technology (Netherlands); Academic Medical Center, Urology Dept., University of Amsterdam (Netherlands)

    2015-10-28

    Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO{sup ®} UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

  14. Comparison of texture models for efficient ultrasound image retrieval

    Science.gov (United States)

    Bansal, Maggi; Sharma, Vipul; Singh, Sukhwinder

    2013-02-01

    Due to availability of inexpensive and easily available image capturing devices, the size of digital image collection is increasing rapidly. Thus, there is need to create efficient access methods or retrieval tools to search, browse and retrieve images from large multimedia repositories. More specifically, researchers have been engaged on different ways of retrieving images based on their actual content. In particular, Content Based Image Retrieval (CBIR) systems have attracted considerable research and commercial interest in the recent years. In CBIR, visual features characterizing the image content are color, shape and texture. Currently, texture is used to quantify the image content of medical images as it is the most prominent feature that contains information about the spatial distribution of gray levels and variations in brightness. Various texture models like Haralick's Spatial Gray Level Co-occurence Matrix (SGLCM), Gray Level Difference Statistics (GLDS), First-order Statistics (FoS), Statistical Feature Matrix (SFM), Law's Texture Energy Measures (TEM), Fractal features and Fourier Power Spectrum (FPS) features exists in literature. Each of these models visualizes texture in a different way. Retrieval performance depends upon the choice of texture algorithm. Unfortunately, there is no texture model known to work best for encoding texture properties of liver ultrasound images or retrieving most similar images. An experimental comparison of different texture models for Content Based Medical Image Retrieval (CBMIR) is presented in this paper. For the experiments, liver ultrasound image database is used and the retrieval performance of the various texture models is analyzed in detail. The paper concludes with recommendations which texture model performs better for liver ultrasound images. Interestingly, FPS and SGLCM based Haralick's features perform well for liver ultrasound retrieval and thus can be recommended as a simple baseline for such images.

  15. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  16. Dual-Modality PET/Ultrasound imaging of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-11-11

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems.

  17. Ultrasound imaging of the lactating breast: methodology and application

    Directory of Open Access Journals (Sweden)

    Geddes Donna T

    2009-04-01

    Full Text Available Abstract Ultrasound imaging has been used extensively to detect abnormalities of the non-lactating breast. In contrast, the use of ultrasound for the investigation of pathology of the lactating breast is limited. Recent studies have re-examined the anatomy of the lactating breast highlighting features unique to this phase of breast development. These features should be taken into consideration along with knowledge of common lactation pathologies in order to make an accurate diagnosis when examining the lactating breast. Scanning techniques and ultrasound appearances of the normal lactating breast will be contrasted to those of the non-lactating breast. In addition ultrasound characteristics of common pathologies encountered during lactation will be described.

  18. Integrated intravascular optical coherence tomography ultrasound imaging system

    Science.gov (United States)

    Yin, Jiechen; Yang, Hao-Chung; Li, Xiang; Zhang, Jun; Zhou, Qifa; Hu, Changhong; Shung, K. Kirk; Chen, Zhongping

    2010-01-01

    We report on a dual-modality optical coherence tomography (OCT) ultrasound (US) system for intravascular imaging. To the best of our knowledge, we have developed the first integrated OCT-US probe that combines OCT optical components with an US transducer. The OCT optical components mainly consist of a single-mode fiber, a gradient index lens for light-beam focusing, and a right-angled prism for reflecting light into biological tissue. A 40-MHz piezoelectric transducer (PZT-5H) side-viewing US transducer was fabricated to obtain the US image. These components were integrated into a single probe, enabling both OCT and US imaging at the same time. In vitro OCT and ultrasound images of a rabbit aorta were obtained using this dual-modality imaging system. This study demonstrates the feasibility of an OCT-US system for intravascular imaging, which is expected to have a prominent impact on early detection and characterization of atherosclerosis.

  19. Effect of Enhancement Technique on Nonuniform and Uniform Ultrasound Images

    Directory of Open Access Journals (Sweden)

    Parveen Lehana

    2015-01-01

    Full Text Available The absence of adequate scientific resources in the area of medical sciences sometimes leads to improper diagnosis of diseases and hence the treatments of such diseases are affected badly. However, with the advancement of technology, the complicacy of various malfunctions inside the human body reduces. Ultrasound imaging is one of the biomedical scanning techniques that let the pathologist make comment reasonably and accurately on the disease or irregularity seen in the scan while low imaging quality lets the diagnosis go wrong. Even a little distortion can route the pathologist away from the main cause of the disease. In this research work, the enhancement of dark ultrasound images has been done. An algorithm is developed using enhancement technique for nonuniform and uniform dark images. Finally, we compared the quality of the processed and unprocessed images. Both ETNUD and mean and median filtering techniques were used for image analysis.

  20. Experience With Intravascular Ultrasound Imaging Of Human Atherosclerotic Arteries

    Science.gov (United States)

    Mallery, John A.; Gessert, James M.; Maciel, Mario; Tobis, John M.; Griffith, James M.; Berns, Michael W.; Henry, Walter L.

    1989-08-01

    Normal human arteries have a well-defined structure on intravascular images. The intima appears very thin and is most likely represented by a bright reflection arising from the internal elastic lamina. The smooth muscle tunica media is echo-lucent on the ultrasound image and appears as a dark band separating the intima from the adventitia. The adventitia is a brightly reflective layer of variable thickness. The thickness of the intima, and therefore of the atherosclerotic plaque can be accurately measured from the ultrasound images and correlates well with histology. Calcification within the wall of arteries is seen as bright echo reflection with shadowing of the peripheral wall. Fibrotic regions are highly reflective but do not shadow. Necrotic liquid regions within advanced atherosclerotic plaques are seen on ultrasound images as large lucent zones surrounded by echogenic tissue. Imaging can be performed before and after interventional procedures, such as laser angioplasty, balloon angioplasty and atherectomy. Intravascular ultrasound appears to provide an imaging modality for identifying the histologic characteristics of diseased arteries and for quantifying plaque thickness. It might be possible to perform such quantification to evaluate the results of interventional procedures.

  1. Regularized Image Reconstruction for Ultrasound Attenuation Transmission Tomography

    Directory of Open Access Journals (Sweden)

    I. Peterlik

    2008-06-01

    Full Text Available The paper is focused on ultrasonic transmission tomography as a potential medical imaging modality, namely for breast cancer diagnosis. Ultrasound attenuation coefficient is one of the tissue parameters which are related to the pathological tissue state. A technique to reconstruct images of attenuation distribution is presented. Furthermore, an alternative to the commonly used filtered backprojection or algebraic reconstruction techniques is proposed. It is based on regularization of the image reconstruction problem which imposes smoothness in the resulting images while preserving edges. The approach is analyzed on synthetic data sets. The results show that it stabilizes the image restoration by compensating for main sources of estimation errors in this imaging modality.

  2. Multiparametric Quantitative Ultrasound Imaging in Assessment of Chronic Kidney Disease.

    Science.gov (United States)

    Gao, Jing; Perlman, Alan; Kalache, Safa; Berman, Nathaniel; Seshan, Surya; Salvatore, Steven; Smith, Lindsey; Wehrli, Natasha; Waldron, Levi; Kodali, Hanish; Chevalier, James

    2017-11-01

    To evaluate the value of multiparametric quantitative ultrasound imaging in assessing chronic kidney disease (CKD) using kidney biopsy pathologic findings as reference standards. We prospectively measured multiparametric quantitative ultrasound markers with grayscale, spectral Doppler, and acoustic radiation force impulse imaging in 25 patients with CKD before kidney biopsy and 10 healthy volunteers. Based on all pathologic (glomerulosclerosis, interstitial fibrosis/tubular atrophy, arteriosclerosis, and edema) scores, the patients with CKD were classified into mild (no grade 3 and quantitative ultrasound parameters included kidney length, cortical thickness, pixel intensity, parenchymal shear wave velocity, intrarenal artery peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index. We tested the difference in quantitative ultrasound parameters among mild CKD, moderate to severe CKD, and healthy controls using analysis of variance, analyzed correlations of quantitative ultrasound parameters with pathologic scores and the estimated glomerular filtration rate (GFR) using Pearson correlation coefficients, and examined the diagnostic performance of quantitative ultrasound parameters in determining moderate CKD and an estimated GFR of less than 60 mL/min/1.73 m 2 using receiver operating characteristic curve analysis. There were significant differences in cortical thickness, pixel intensity, PSV, and EDV among the 3 groups (all P quantitative ultrasound parameters, the top areas under the receiver operating characteristic curves for PSV and EDV were 0.88 and 0.97, respectively, for determining pathologic moderate to severe CKD, and 0.76 and 0.86 for estimated GFR of less than 60 mL/min/1.73 m 2 . Moderate to good correlations were found for PSV, EDV, and pixel intensity with pathologic scores and estimated GFR. The PSV, EDV, and pixel intensity are valuable in determining moderate to severe CKD. The value of shear wave velocity in

  3. Ultrasound versus high field magnetic resonance imaging in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Tan, York Kiat; Østergaard, Mikkel; Bird, Paul

    2014-01-01

    Over the past decade there have been significant advances in the field of musculoskeletal imaging, especially in the application of ultrasound (US) and magnetic resonance imaging (MRI) to the management of rheumatoid arthritis (RA). Both modalities offer significant advantages over the previous...... standards of clinical examination and radiography, and allow direct visualisation of both joint inflammation and structural damage. Although measuring similar pathology, each of these imaging tools has its own benefits and limitations; understanding these will help researchers and clinicians to determine...

  4. Vessel detection in ultrasound images using deep convolutional neural networks

    OpenAIRE

    Smistad, Erik; Løvstakken, Lasse

    2016-01-01

    Deep convolutional neural networks have achieved great results on image classification problems. In this paper, a new method using a deep convolutional neural network for detecting blood vessels in B-mode ultrasound images is presented. Automatic blood vessel detection may be useful in medical applications such as deep venous thrombosis detection, anesthesia guidance and catheter placement. The proposed method is able to determine the position and size of the vessels in images in real-time. 1...

  5. In vivo photoacoustics and high frequency ultrasound imaging of mechanical high intensity focused ultrasound (HIFU) ablation

    NARCIS (Netherlands)

    Daoudi, K.; Hoogenboom, M.; Brok, M.H. den; Eikelenboom, D.C.; Adema, G.J.; Futterer, J.J.; Korte, C.L. de

    2017-01-01

    The thermal effect of high intensity focused ultrasound (HIFU) has been clinically exploited over a decade, while the mechanical HIFU is still largely confined to laboratory investigations. This is in part due to the lack of adequate imaging techniques to better understand the in-vivo pathological

  6. Vascular applications of contrast-enhanced ultrasound imaging.

    Science.gov (United States)

    Mehta, Kunal S; Lee, Jake J; Taha, Ashraf A; Avgerinos, Efthymios; Chaer, Rabih A

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) imaging is a powerful noninvasive modality offering numerous potential diagnostic and therapeutic applications in vascular medicine. CEUS imaging uses microbubble contrast agents composed of an encapsulating shell surrounding a gaseous core. These microbubbles act as nearly perfect intravascular reflectors of ultrasound energy and may be used to enhance the overall contrast and quality of ultrasound images. The purpose of this narrative review is to survey the current literature regarding CEUS imaging and discuss its diagnostic and therapeutic roles in current vascular and selected nonvascular applications. The PubMed, MEDLINE, and Embase databases were searched until July 2016 using the PubMed and Ovid Web-based search engines. The search terms used included contrast-enhanced, microbubble, ultrasound, carotid, aneurysm, and arterial. The diagnostic and therapeutic utility of CEUS imaging has grown exponentially, particularly in the realms of extracranial carotid arterial disease, aortic disease, and peripheral arterial disease. Studies have demonstrated that CEUS imaging is diagnostically superior to conventional ultrasound imaging in identifying vessel irregularities and measuring neovascularization to assess plaque vulnerability and end-muscle perfusion. Groups have begun to use microbubbles as agents in therapeutic applications for targeted drug and gene therapy delivery as well as for the enhancement of sonothrombolysis. The emerging technology of microbubbles and CEUS imaging holds considerable promise for cardiovascular medicine and cancer therapy given its diagnostic and therapeutic utility. Overall, with proper training and credentialing of technicians, the clinical implications are innumerable as microbubble technology is rapidly bursting onto the scene of cardiovascular medicine. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Harmonic balance analysis of the subharmonic ferroresonance

    Energy Technology Data Exchange (ETDEWEB)

    Akpinar, A.S. (Dept. of Electrical Engineering, Blacksea Technical Univ., Trabzon (TR)); Nasar, S.A. (Kentucky Univ., Lexington, KY (USA). Dept. of Electrical Engineering)

    1990-01-01

    An increasing use of series capacitors to overcome the inductive voltage drops and to improve the power factor in distribution systems has revived the interest in ferrorsonance phenomenon. In this paper, an analytical approach and stability criteria for the sustained subharmonic ferroresonance phenomenon is presented. Certain comparisons between experimental and calculated results are included.

  8. Strain imaging of corneal tissue with an ultrasound elasticity microscope.

    Science.gov (United States)

    Hollman, Kyle W; Emelianov, Stanislav Y; Neiss, Jason H; Jotyan, Gagik; Spooner, Gregory J R; Juhasz, Tibor; Kurtz, Ron M; O'Donnell, Matthew

    2002-01-01

    We hypothesize that high-resolution elasticity measurements can guide corrective refractive surgery of the cornea. Elasticity measurements would improve surgical outcomes by adding biomechanical information not used in existing clinical nomograms. As an initial investigation, we determined the usefulness and evaluated the ability of our ultrasound elasticity microscope by measuring strain ex vivo in an intact porcine eye globe. Strain was predicted with a finite element model guided by direct mechanical measurements of corneal elasticity. Next, a porcine cornea was deformed with a slitted plate while being imaged with ultrasound. For high spatial resolution, the ultrasound elasticity microscope uses a 50 MHz transducer with a 1.4 f/number. It produces high-quality conventional ultrasonic B-scans over large thicknesses by confocal processing. Strain was calculated from tracking speckle in these images after deformation. This technique is compatible with in vivo measurements. Compressional and expansional deformations were the same order of magnitude from -3.5% to as great as +3.5%. Strain imaging indicated the stroma expanded into the slit of the deformation plate while Bowman's layer compressed. This bipolar variation within a specimen is unusual. Within the stroma, a variation of strain with depth was measured suggesting a distribution of elasticity. Results compared favorably with the finite element model. An ultrasound elasticity microscope can produce high-resolution strain images throughout the corneal depth. Various layers with different elastic properties appeared as different strains in the images.

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... are the limitations of Pelvic Ultrasound Imaging? What is Pelvic Ultrasound Imaging? Ultrasound is safe and painless, ... top of page What are some common uses of the procedure? In women, a pelvic ultrasound is ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces ... of page What are some common uses of the procedure? A transrectal ultrasound of the prostate gland ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  13. Ultrasound elastography for imaging tendons and muscles

    Directory of Open Access Journals (Sweden)

    Elena Drakonaki

    2012-06-01

    Full Text Available Ultrasound elastography is a recently developed ultrasound-based method which allows the qualitative or quantitative evaluation of the mechanical properties of tissue. Strain (compression ultrasound elastography is the commonest technique performed by ap‑ plying mild compression with the hand-held transducer to create real-time strain dis‑ tribution maps, which are color-coded and superimposed on the B-mode images. There is increasing evidence that ultrasound elastography can be used in the investigation of muscle, tendon and soft tissue disease in the clinical practice, as a supplementary tool to conventional ultrasound examination. Based on preliminary data, potential clinical appli‑ cations include early diagnosis, staging, and guiding interventions musculotendinous and neuromuscular disease as well as monitoring disease during rehabilitation. Ultrasound elastography could also be used for research into the biomechanics and pathophysiology of musculotendinous disease. Despite the great interest in the technique, there is still limited evidence in the literature and there are several technical issues which limit the reproducibility of the method, including differences in quantification methods, artefacts, limitations and variation in the application of the technique by different users. This re‑ view presents the published evidence on musculoskeletal applications of strain elastogra‑ phy, discusses the technical issues and future perspectives of this method and emphasizes the need for standardization and further research.

  14. Adaptive ultrasound temperature imaging for monitoring radiofrequency ablation.

    Directory of Open Access Journals (Sweden)

    Yi-Da Liu

    Full Text Available Radiofrequency ablation (RFA has been widely used as an alternative treatment modality for liver tumors. Monitoring the temperature distribution in the tissue during RFA is required to assess the thermal dosage. Ultrasound temperature imaging based on the detection of echo time shifts has received the most attention in the past decade. The coefficient k, connecting the temperature change and the echo time shift, is a medium-dependent parameter used to describe the confounding effects of changes in the speed of sound and thermal expansion as temperature increases. The current algorithm of temperature estimate based on echo time shift detection typically uses a constant k, resulting in estimation errors when ablation temperatures are higher than 50°C. This study proposes an adaptive-k algorithm that enables the automatic adjustment of the coefficient k during ultrasound temperature monitoring of RFA. To verify the proposed algorithm, RFA experiments on in vitro porcine liver samples (total n = 15 were performed using ablation powers of 10, 15, and 20 W. During RFA, a clinical ultrasound system equipped with a 7.5-MHz linear transducer was used to collect backscattered signals for ultrasound temperature imaging using the constant- and adaptive-k algorithms. Concurrently, an infrared imaging system and thermocouples were used to measure surface temperature distribution of the sample and internal ablation temperatures for comparisons with ultrasound estimates. Experimental results demonstrated that the proposed adaptive-k method improved the performance in visualizing the temperature distribution. In particular, the estimation errors were also reduced even when the temperature of the tissue is higher than 50°C. The proposed adaptive-k ultrasound temperature imaging strategy has potential to serve as a thermal dosage evaluation tool for monitoring high-temperature RFA.

  15. Enhanced ultrasound for advanced diagnostics, ultrasound tomography for volume limb imaging and prosthetic fitting

    Science.gov (United States)

    Anthony, Brian W.

    2016-04-01

    Ultrasound imaging methods hold the potential to deliver low-cost, high-resolution, operator-independent and nonionizing imaging systems - such systems couple appropriate algorithms with imaging devices and techniques. The increasing demands on general practitioners motivate us to develop more usable and productive diagnostic imaging equipment. Ultrasound, specifically freehand ultrasound, is a low cost and safe medical imaging technique. It doesn't expose a patient to ionizing radiation. Its safety and versatility make it very well suited for the increasing demands on general practitioners, or for providing improved medical care in rural regions or the developing world. However it typically suffers from sonographer variability; we will discuss techniques to address user variability. We also discuss our work to combine cylindrical scanning systems with state of the art inversion algorithms to deliver ultrasound systems for imaging and quantifying limbs in 3-D in vivo. Such systems have the potential to track the progression of limb health at a low cost and without radiation exposure, as well as, improve prosthetic socket fitting. Current methods of prosthetic socket fabrication remain subjective and ineffective at creating an interface to the human body that is both comfortable and functional. Though there has been recent success using methods like magnetic resonance imaging and biomechanical modeling, a low-cost, streamlined, and quantitative process for prosthetic cup design and fabrication has not been fully demonstrated. Medical ultrasonography may inform the design process of prosthetic sockets in a more objective manner. This keynote talk presents the results of progress in this area.

  16. Mechanical scanning in intravascular ultrasound imaging: Artifacts and driving mechanisms

    NARCIS (Netherlands)

    H. ten Hoff (H.); E.J. Gussenhoven (Elma); C.M. Korbijn (Carin); F. Mastik (Frits); C.T. Lancée (Charles); N. Bom (Klaas)

    1995-01-01

    textabstractObjective: Currently, intravascular ultrasound (US) imaging catheters are developed and produced to provide a complementary diagnostic method in the treatment of blood vessel obstructive disease. Typical catheter dimensions are a diameter of 1–2.5 mm and a length of 1–1.5 m. A real-time

  17. Automated Hierarchical Time Gain Compensation for In Vivo Ultrasound Imaging

    DEFF Research Database (Denmark)

    Moshavegh, Ramin; Hemmsen, Martin Christian; Martins, Bo

    2015-01-01

    Time gain compensation (TGC) is essential to ensure the optimal image quality of the clinical ultrasound scans. When large fluid collections are present within the scan plane, the attenuation distribution is changed drastically and TGC compensation becomes challenging. This paper presents an auto...

  18. Comparing different ultrasound imaging methods for breast cancer detection

    NARCIS (Netherlands)

    Ozmen, N.; Dapp, R.; Zapf, M.; Gemmeke, H.; Ruiter, N.V.; Van Dongen, K.W.A.

    2015-01-01

    Ultrasound is frequently used to evaluate suspicious masses in breasts. These evaluations could be improved by taking advantage of advanced imaging algorithms, which become feasible for low frequencies if accurate knowledge about the phase and amplitude of the wave field illuminating the volume of

  19. Robust microbubble tracking for super resolution imaging in ultrasound

    DEFF Research Database (Denmark)

    Hansen, Kristoffer B.; Villagómez Hoyos, Carlos Armando; Brasen, Jens Christian

    2016-01-01

    Currently ultrasound resolution is limited by diffraction to approximately half the wavelength of the sound wave employed. In recent years, super resolution imaging techniques have overcome the diffraction limit through the localization and tracking of a sparse set of microbubbles through the vas...

  20. Imaging the premature brain: ultrasound or MRI?

    Energy Technology Data Exchange (ETDEWEB)

    Vries, Linda S. de; Benders, Manon J.N.L.; Groenendaal, Floris [UMC Utrecht, Department of Neonatology, Wilhelmina Children' s Hospital, PO Box 85090, Utrecht (Netherlands)

    2013-09-15

    Neuroimaging of preterm infants has become part of routine clinical care, but the question is often raised on how often cranial ultrasound should be done and whether every high risk preterm infant should at least have one MRI during the neonatal period. An increasing number of centres perform an MRI either at discharge or around term equivalent age, and a few centres have access to a magnet in or adjacent to the neonatal intensive care unit and are doing sequential MRIs. In this review, we try to discuss when best to perform these two neuroimaging techniques and the additional information each technique may provide. (orig.)

  1. Coregistered photoacoustic-ultrasound imaging applied to brachytherapy

    Science.gov (United States)

    Harrison, Tyler; Zemp, Roger J.

    2011-08-01

    Brachytherapy is a form of radiation therapy commonly used in the treatment of prostate cancer wherein sustained radiation doses can be precisely targeted to the tumor area by the implantation of small radioactive seeds around the treatment area. Ultrasound is a popular imaging mode for seed implantation, but the seeds are difficult to distinguish from the tissue structure. In this work, we demonstrate the feasibility of photoacoustic imaging for identifying brachytherapy seeds in a tissue phantom, comparing the received intensity to endogenous contrast. We have found that photoacoustic imaging at 1064 nm can identify brachytherapy seeds uniquely at laser penetration depths of 5 cm in biological tissue at the ANSI limit for human exposure with a contrast-to-noise ratio of 26.5 dB. Our realtime combined photoacoustic-ultrasound imaging approach may be suitable for brachytherapy seed placement and post-placement verification, potentially allowing for realtime dosimetry assessment during implantation.

  2. High resolution ultrasound and photoacoustic imaging of single cells

    Directory of Open Access Journals (Sweden)

    Eric M. Strohm

    2016-03-01

    Full Text Available High resolution ultrasound and photoacoustic images of stained neutrophils, lymphocytes and monocytes from a blood smear were acquired using a combined acoustic/photoacoustic microscope. Photoacoustic images were created using a pulsed 532 nm laser that was coupled to a single mode fiber to produce output wavelengths from 532 nm to 620 nm via stimulated Raman scattering. The excitation wavelength was selected using optical filters and focused onto the sample using a 20× objective. A 1000 MHz transducer was co-aligned with the laser spot and used for ultrasound and photoacoustic images, enabling micrometer resolution with both modalities. The different cell types could be easily identified due to variations in contrast within the acoustic and photoacoustic images. This technique provides a new way of probing leukocyte structure with potential applications towards detecting cellular abnormalities and diseased cells at the single cell level.

  3. High Resolution Depth-Resolved Imaging From Multi-Focal Images for Medical Ultrasound

    DEFF Research Database (Denmark)

    Diamantis, Konstantinos; Dalgarno, Paul A.; Greenaway, Alan H.

    2015-01-01

    An ultrasound imaging technique providing subdiffraction limit axial resolution for point sources is proposed. It is based on simultaneously acquired multi-focal images of the same object, and on the image metric of sharpness. The sharpness is extracted by image data and presents higher values...... for in-focus images. The technique is derived from biological microscopy and is validated here with simulated ultrasound data. A linear array probe is used to scan a point scatterer phantom that moves in depth with a controlled step. From the beamformed responses of each scatterer position the image...

  4. Non-Contact Optical Ultrasound Concept for Biomedical Imaging

    Science.gov (United States)

    2016-11-03

    reflection images of a phantom limb that contains muscle and bone surrogate materials and use the data for inversion of the Young’s modulus... original higher frequency signal, but is oscillating at a lower more easily processed carrier frequency. Electrical field oscillations in the optical...Figure 9. 2D Slice of rotational reflection laser ultrasound image of phantom limb with PVC pipe as bone surrounded by gel as muscle mass. In

  5. Beamforming through regularized inverse problems in ultrasound medical imaging

    OpenAIRE

    Szasz, Teodora; Basarab, Adrian; Kouamé, Denis

    2015-01-01

    Beamforming in ultrasound imaging has significant impact on the quality of the final image, controlling its resolution and contrast. Despite its low spatial resolution and contrast, delay-and-sum is still extensively used nowadays in clinical applications, due to its real-time capabilities. The most common alternatives are minimum variance method and its variants, which overcome the drawbacks of delay-and-sum, at the cost of higher computational complexity that limits its utilization in real-...

  6. Development of Ultrasound Tomography for Breast Imaging: Technical Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Duric, N; Littrup, P; Babkin, A; Chambers, D; Azevedo, S; Arkady, K; Pevzner, R; Tokarev, M; Holsapple, E

    2004-09-30

    Ultrasound imaging is widely used in medicine because of its benign characteristics and real-time capabilities. Physics theory suggests that the application of tomographic techniques may allow ultrasound imaging to reach its full potential as a diagnostic tool allowing it to compete with other tomographic modalities such as X-ray CT and MRI. This paper describes the construction and use of a prototype tomographic scanner and reports on the feasibility of implementing tomographic theory in practice and the potential of US tomography in diagnostic imaging. Data were collected with the prototype by scanning two types of phantoms and a cadaveric breast. A specialized suite of algorithms was developed and utilized to construct images of reflectivity and sound speed from the phantom data. The basic results can be summarized as follows: (1) A fast, clinically relevant US tomography scanner can be built using existing technology. (2) The spatial resolution, deduced from images of reflectivity, is 0.4 mm. The demonstrated 10 cm depth-of-field is superior to that of conventional ultrasound and the image contrast is improved through the reduction of speckle noise and overall lowering of the noise floor. (3) Images of acoustic properties such as sound speed suggest that it is possible to measure variations in the sound speed of 5 m/s. An apparent correlation with X-ray attenuation suggests that the sound speed can be used to discriminate between various types of soft tissue. (4) Ultrasound tomography has the potential to improve diagnostic imaging in relation to breast cancer detection.

  7. Towards CT-quality Ultrasound Imaging using Deep Learning

    OpenAIRE

    Vedula, Sanketh; Senouf, Ortal; Bronstein, Alex M.; Michailovich, Oleg V.; Zibulevsky, Michael

    2017-01-01

    The cost-effectiveness and practical harmlessness of ultrasound imaging have made it one of the most widespread tools for medical diagnosis. Unfortunately, the beam-forming based image formation produces granular speckle noise, blurring, shading and other artifacts. To overcome these effects, the ultimate goal would be to reconstruct the tissue acoustic properties by solving a full wave propagation inverse problem. In this work, we make a step towards this goal, using Multi-Resolution Convolu...

  8. Ultrasound contrast agent fabricated from microbubbles containing instant adhesives, and its ultrasound imaging ability

    Science.gov (United States)

    Makuta, T.; Tamakawa, Y.

    2012-04-01

    Non-invasive surgery techniques and drug delivery system with acoustic characteristics of ultrasound contrast agent have been studied intensively in recent years. Ultrasound contrast agent collapses easily under the blood circulating and the ultrasound irradiating because it is just a stabilized bubble without solid-shell by surface adsorption of surfactant or lipid. For improving the imaging stability, we proposed the fabrication method of the hollow microcapsule with polymer shell, which can be fabricated just blowing vapor of commonly-used instant adhesive (Cyanoacrylate monomer) into water as microbubbles. Therefore, the cyanoacrylate vapor contained inside microbubble initiates polymerization on the gasliquid interface soon after microbubbles are generated in water. Consequently, hollow microspheres coated by cyanoacrylate thin film are generated. In this report, we revealed that diameter distributions of microbubbles and microcapsules were approximately same and most of them were less than 10 μm, that is, smaller than blood capillary. In addition, we also revealed that hollow microcapsules enhanced the acoustic signal especially in the harmonic contrast imaging and were broken or agglomerated under the ultrasound field. As for the yield of hollow microcapsules, we revealed that sodium dodecyl sulfate addition to water phase instead of deoxycolic acid made the fabrication yield increased.

  9. Parametric Beamformer for Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Tomov, Borislav Gueorguiev; Jensen, Jørgen Arendt

    2006-01-01

    In this paper a parametric beamformer, which can handle all imaging modalities including synthetic aperture imaging, is presented. The image lines and apodization coefficients are specified parametrically, and the lines can have arbitrary orientation and starting point in 3D coordinates...

  10. Cumulative phase delay imaging for contrast-enhanced ultrasound tomography

    Science.gov (United States)

    Demi, Libertario; van Sloun, Ruud J. G.; Wijkstra, Hessel; Mischi, Massimo

    2015-11-01

    Standard dynamic-contrast enhanced ultrasound (DCE-US) imaging detects and estimates ultrasound-contrast-agent (UCA) concentration based on the amplitude of the nonlinear (harmonic) components generated during ultrasound (US) propagation through UCAs. However, harmonic components generation is not specific to UCAs, as it also occurs for US propagating through tissue. Moreover, nonlinear artifacts affect standard DCE-US imaging, causing contrast to tissue ratio reduction, and resulting in possible misclassification of tissue and misinterpretation of UCA concentration. Furthermore, no contrast-specific modality exists for DCE-US tomography; in particular speed-of-sound changes due to UCAs are well within those caused by different tissue types. Recently, a new marker for UCAs has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental component is in fact observable for US propagating through UCAs, and is absent in tissue. In this paper, tomographic US images based on CPD are for the first time presented and compared to speed-of-sound US tomography. Results show the applicability of this marker for contrast specific US imaging, with cumulative phase delay imaging (CPDI) showing superior capabilities in detecting and localizing UCA, as compared to speed-of-sound US tomography. Cavities (filled with UCA) which were down to 1 mm in diameter were clearly detectable. Moreover, CPDI is free of the above mentioned nonlinear artifacts. These results open important possibilities to DCE-US tomography, with potential applications to breast imaging for cancer localization.

  11. Imaging patients with renal colic-consider ultrasound first

    DEFF Research Database (Denmark)

    Nicolau, Carlos; Claudon, Michel; Derchi, Lorenzo E

    2015-01-01

    stones. However, ultrasound (US) should be considered as the primary imaging technique. It is a reproducible, non-invasive and non-expensive imaging technique, achieving accurate diagnosis in most cases without the need for radiation. Diagnosis is based on the presence of ureteral stones, but indirect...... of renal colic is based on the detection of ureteral stones. • CT is the most accurate imaging technique to identify ureteral stones. • US allows correct diagnosis in most cases without using radiation. • US should be used as the first imaging modality in patients with renal colic....

  12. [Digital scanning converter for medical endoscopic ultrasound imaging].

    Science.gov (United States)

    Chen, Xiaodong; Zhang, Hongxu; Zhou, Peifan; Wen, Shijie; Yu, Daoyin

    2009-02-01

    This paper mainly introduces the design of digital scanning converter (DSC) for medical endoscopic ultrasound imaging. Fast modified vector totational CORDIC (FMVR-CORDIC) arithmetic complete coordinate conversion is used to increase the speed of ultrasonic scanning imaging. FPGA is used as the kernel module to control data transferring, related circuits and relevant chips' working, and to accomplish data preprocessing. With the advantages of simple structure, nice flexibility and convenience, it satisfies the demand for real-time displaying in this system. Finally, the original polar coordinate image is transformed to rectangular coordinate grey image through coordinate transformation. The system performances have been validated by the experimental result.

  13. Modelling human musculoskeletal functional movements using ultrasound imaging

    Directory of Open Access Journals (Sweden)

    Stenlund Hans

    2010-05-01

    Full Text Available Abstract Background A widespread and fundamental assumption in the health sciences is that muscle functions are related to a wide variety of conditions, for example pain, ischemic and neurological disorder, exercise and injury. It is therefore highly desirable to study musculoskeletal contributions in clinical applications such as the treatment of muscle injuries, post-surgery evaluations, monitoring of progressive degeneration in neuromuscular disorders, and so on. The spatial image resolution in ultrasound systems has improved tremendously in the last few years and nowadays provides detailed information about tissue characteristics. It is now possible to study skeletal muscles in real-time during activity. Methods The ultrasound images are transformed to be congruent and are effectively compressed and stacked in order to be analysed with multivariate techniques. The method is applied to a relevant clinical orthopaedic research field, namely to describe the dynamics in the Achilles tendon and the calf during real-time movements. Results This study introduces a novel method to medical applications that can be used to examine ultrasound image sequences and to detect, visualise and quantify skeletal muscle dynamics and functions. Conclusions This new objective method is a powerful tool to use when visualising tissue activity and dynamics of musculoskeletal ultrasound registrations.

  14. Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies

    Science.gov (United States)

    Arvanitis, Costas D.; McDannold, Nathan

    2013-01-01

    Purpose: Ultrasound can be used to noninvasively produce different bioeffects via viscous heating, acoustic cavitation, or their combination, and these effects can be exploited to develop a wide range of therapies for cancer and other disorders. In order to accurately localize and control these different effects, imaging methods are desired that can map both temperature changes and cavitation activity. To address these needs, the authors integrated an ultrasound imaging array into an MRI-guided focused ultrasound (MRgFUS) system to simultaneously visualize thermal and mechanical effects via passive acoustic mapping (PAM) and MR temperature imaging (MRTI), respectively. Methods: The system was tested with an MRgFUS system developed for transcranial sonication for brain tumor ablation in experiments with a tissue mimicking phantom and a phantom-filled ex vivo macaque skull. In experiments on cavitation-enhanced heating, 10 s continuous wave sonications were applied at increasing power levels (30–110 W) until broadband acoustic emissions (a signature for inertial cavitation) were evident. The presence or lack of signal in the PAM, as well as its magnitude and location, were compared to the focal heating in the MRTI. Additional experiments compared PAM with standard B-mode ultrasound imaging and tested the feasibility of the system to map cavitation activity produced during low-power (5 W) burst sonications in a channel filled with a microbubble ultrasound contrast agent. Results: When inertial cavitation was evident, localized activity was present in PAM and a marked increase in heating was observed in MRTI. The location of the cavitation activity and heating agreed on average after registration of the two imaging modalities; the distance between the maximum cavitation activity and focal heating was −3.4 ± 2.1 mm and −0.1 ± 3.3 mm in the axial and transverse ultrasound array directions, respectively. Distortions and other MRI issues introduced small

  15. Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies.

    Science.gov (United States)

    Arvanitis, Costas D; McDannold, Nathan

    2013-11-01

    Ultrasound can be used to noninvasively produce different bioeffects via viscous heating, acoustic cavitation, or their combination, and these effects can be exploited to develop a wide range of therapies for cancer and other disorders. In order to accurately localize and control these different effects, imaging methods are desired that can map both temperature changes and cavitation activity. To address these needs, the authors integrated an ultrasound imaging array into an MRI-guided focused ultrasound (MRgFUS) system to simultaneously visualize thermal and mechanical effects via passive acoustic mapping (PAM) and MR temperature imaging (MRTI), respectively. The system was tested with an MRgFUS system developed for transcranial sonication for brain tumor ablation in experiments with a tissue mimicking phantom and a phantom-filled ex vivo macaque skull. In experiments on cavitation-enhanced heating, 10 s continuous wave sonications were applied at increasing power levels (30-110 W) until broadband acoustic emissions (a signature for inertial cavitation) were evident. The presence or lack of signal in the PAM, as well as its magnitude and location, were compared to the focal heating in the MRTI. Additional experiments compared PAM with standard B-mode ultrasound imaging and tested the feasibility of the system to map cavitation activity produced during low-power (5 W) burst sonications in a channel filled with a microbubble ultrasound contrast agent. When inertial cavitation was evident, localized activity was present in PAM and a marked increase in heating was observed in MRTI. The location of the cavitation activity and heating agreed on average after registration of the two imaging modalities; the distance between the maximum cavitation activity and focal heating was -3.4 ± 2.1 mm and -0.1 ± 3.3 mm in the axial and transverse ultrasound array directions, respectively. Distortions and other MRI issues introduced small uncertainties in the PAM

  16. Advanced automated gain adjustments for in-vivo ultrasound imaging

    DEFF Research Database (Denmark)

    Moshavegh, Ramin; Hemmsen, Martin Christian; Martins, Bo

    2015-01-01

    Automatic gain adjustments are necessary on the state-of-the-art ultrasound scanners to obtain optimal scan quality, while reducing the unnecessary user interactions with the scanner. However, when large anechoic regions exist in the scan plane, the sudden and drastic variation of attenuations...... ultrasonic physical estimates such as scattering strength, focus gain, acoustic attenuation, and noise level to gain a more quantitative understanding of the scanned media and to provide an intuitive adjustment of gains on the scan. The proposed algorithm was applied to a set of 45 in-vivo movie sequences...... each containing 50 frames. The scans are acquired using a recently commercialized BK3000 ultrasound scanner (BK Ultrasound, Denmark). Matching pairs of in-vivo sequences, unprocessed and processed with the proposed method were visualized side by side and evaluated by 4 radiologists for image quality...

  17. Development of a control algorithm for the ultrasound scanning robot (NCCUSR) using ultrasound image and force feedback.

    Science.gov (United States)

    Kim, Yeoun Jae; Seo, Jong Hyun; Kim, Hong Rae; Kim, Kwang Gi

    2017-06-01

    Clinicians who frequently perform ultrasound scanning procedures often suffer from musculoskeletal disorders, arthritis, and myalgias. To minimize their occurrence and to assist clinicians, ultrasound scanning robots have been developed worldwide. Although, to date, there is still no commercially available ultrasound scanning robot, many control methods have been suggested and researched. These control algorithms are either image based or force based. If the ultrasound scanning robot control algorithm was a combination of the two algorithms, it could benefit from the advantage of each one. However, there are no existing control methods for ultrasound scanning robots that combine force control and image analysis. Therefore, in this work, a control algorithm is developed for an ultrasound scanning robot using force feedback and ultrasound image analysis. A manipulator-type ultrasound scanning robot named 'NCCUSR' is developed and a control algorithm for this robot is suggested and verified. First, conventional hybrid position-force control is implemented for the robot and the hybrid position-force control algorithm is combined with ultrasound image analysis to fully control the robot. The control method is verified using a thyroid phantom. It was found that the proposed algorithm can be applied to control the ultrasound scanning robot and experimental outcomes suggest that the images acquired using the proposed control method can yield a rating score that is equivalent to images acquired directly by the clinicians. The proposed control method can be applied to control the ultrasound scanning robot. However, more work must be completed to verify the proposed control method in order to become clinically feasible. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Ultrasound in Radiology: from Anatomic, Functional, Molecular Imaging to Drug Delivery and Image-Guided Therapy

    Science.gov (United States)

    Klibanov, Alexander L.; Hossack, John A.

    2015-01-01

    During the past decade, ultrasound has expanded medical imaging well beyond the “traditional” radiology setting - a combination of portability, low cost and ease of use makes ultrasound imaging an indispensable tool for radiologists as well as for other medical professionals who need to obtain imaging diagnosis or guide a therapeutic intervention quickly and efficiently. Ultrasound combines excellent ability for deep penetration into soft tissues with very good spatial resolution, with only a few exceptions (i.e. those involving overlying bone or gas). Real-time imaging (up to hundreds and thousands frames per second) enables guidance of therapeutic procedures and biopsies; characterization of the mechanical properties of the tissues greatly aids with the accuracy of the procedures. The ability of ultrasound to deposit energy locally brings about the potential for localized intervention encompassing: tissue ablation, enhancing penetration through the natural barriers to drug delivery in the body and triggering drug release from carrier micro- and nanoparticles. The use of microbubble contrast agents brings the ability to monitor and quantify tissue perfusion, and microbubble targeting with ligand-decorated microbubbles brings the ability to obtain molecular biomarker information, i.e., ultrasound molecular imaging. Overall, ultrasound has become the most widely used imaging modality in modern medicine; it will continue to grow and expand. PMID:26200224

  19. Using Neural Networks to Determine the Origin of Medical Ultrasound Images

    OpenAIRE

    Fossan, Øivind

    2017-01-01

    This thesis investigates the possibility of using neural networks to determine the body location of medical ultrasound images. Neural networks were trained on several datasets of both synthetic and real ultrasound images, containing labels with the location of each image. Next, the networks predicted the location of unseen images, and the accuracy was measured. The first dataset consisted of images from three typical locations for ultrasound-guided regional anesthesia, where a classificat...

  20. Reduced speckle noise on medical ultrasound images using cellular neural network.

    Science.gov (United States)

    Park, Hyunkyung; Nishimura, Toshihiro

    2007-01-01

    Speckle noise is indispensable get from ultrasound image. In general tends to reduce the image resolution and contrast. In addition to the doctor diagnosis, is lacking for judgment accuracy. This paper is reduced the speckle noise and enhanced boundary of a tumor in the medical ultrasound images. The proposed method is valuated using numerical phantom simulating ultrasound B-mode images, and the effect is confirmed by applying to medical ultrasound images. Therefore, some important features such as tissue boundaries and small tumors may be overlooked. A cellular neural network which is a kind of recurrent neural network can deal with images by the weight of neurons called a cell. It could be obtained more detail images recognition compared with the previous studies. Determination template parameters of the cellular neural network for ultrasound image processing are discussed. The experimental results show effectiveness of applying the proposed method to boundary enhancement and the speckle noise reduction of medical ultrasound image.

  1. Space-time encoding for high frame rate ultrasound imaging

    DEFF Research Database (Denmark)

    Misaridis, Thanssis; Jensen, Jørgen Arendt

    2002-01-01

    Frame rate in ultrasound imaging can be dramatically increased by using sparse synthetic transmit aperture (STA) beamforming techniques. The two main drawbacks of the method are the low signal-to-noise ratio (SNR) and the motion artifacts, that degrade the image quality. In this paper we propose......, due to the orthogonality of the temporal encoded wavefronts. Thus, with this method, the frame rate is doubled compared to previous systems. Another advantage is the utilization of temporal codes which are more robust to attenuation. With the proposed technique it is possible to obtain images...

  2. Plane-Wave Imaging Challenge in Medical Ultrasound

    DEFF Research Database (Denmark)

    Liebgott, Herve; Molares, Alfonso Rodriguez; Jensen, Jørgen Arendt

    2016-01-01

    Plane-Wave imaging enables very high frame rates, up to several thousand frames per second. Unfortunately the lack of transmit focusing leads to reduced image quality, both in terms of resolution and contrast. Recently, numerous beamforming techniques have been proposed to compensate...... for this effect, but comparing the different methods is difficult due to the lack of appropriate tools. PICMUS, the Plane-Wave Imaging Challenge in Medical Ultrasound aims to provide these tools. This paper describes the PICMUS challenge, its motivation, implementation, and metrics....

  3. Imaging blood’s velocity using synthetic aperture ultrasound

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Li, Ye

    2012-01-01

    The blood velocity vector can be estimated using synthetic aperture techniques in medical ultrasound by using short emission sequences. The whole image region is insonified and the flow can be tracked in all directions continuously. This is a major advantage compared to commercial systems, since...... the separation between blood and tissue is greatly eased by this, and the estimates can be averaged over long time than in traditional systems. Vector velocity imaging can, thus, be made and attain an order of magnitude higher precision than in current commercial systems and at higher frame rates. It is also...... possible to visualize very slow moving flow. The paper will present methods for making such imaging....

  4. A Comparison of Speckle Reduction Techniques in Medical Ultrasound Imaging

    Directory of Open Access Journals (Sweden)

    Cristina STOLOJESCU-CRISAN

    2015-06-01

    Full Text Available Speckle noise is a multiplicative noise that degrades the visual evaluation in ultrasound imaging. In addition, it limits the efficient application of intelligent image processing algorithms, such as segmentation techniques. Thus, speckle noise reduction is considered an essential pre-processing step. The objective of this paper is to carry out a comparative evaluation of speckle filtering techniques, based on two image quality evaluation metrics, the Peak Signal to Noise Ratio (PSNR, and the Structural SIMilarity (SSIM index, and visual evaluation.

  5. Real Time Fast Ultrasound Imaging Technology and Possible Applications

    Science.gov (United States)

    Cruza, J. F.; Perez, M.; Moreno, J. M.; Fritsch, C.

    In this work, a novel hardware architecture for fast ultrasound imaging based on FPGA devices is proposed. A key difference over other approaches is the unlimited scalability in terms of active channels without performance losses. Acquisition and processing tasks share the same hardware, eliminating communication bottlenecks with smaller size and power losses. These features make this system suitable to implement the most demanding imaging applications, like 3D Phased Array, Total Focusing Method, Vector Doppler, Image Compounding, High Speed Part Scanning and advanced elastographic techniques. A single medium sized FPGA allows beamforming up to 200 scan lines simultaneously, which is enough to perform most of the above mentioned applications in strict real time.

  6. Adaptive Receive and Transmit Apodization for Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Holfort, Iben Kraglund; Austeng, Andreas; Synnevåg, Johan-Fredrik

    2009-01-01

    This paper suggests a framework for utilizing adaptive, data-dependent apodization weights on both the receiving and transmitting aperture for Synthetic Aperture (SA) ultrasound imaging. The suggested approach is based on the Minimum Variance (MV) beamformer and consists of two steps. A set...... of uniquely designed receive apodization weights are applied to pre-summed element data forming a set of adaptively weighted images; these are in SA literature conventionally referred to as low-resolution images. The adaptive transmit apodization is obtained by applying MV across the full set of single...

  7. Molecular Ultrasound Imaging for the Detection of Neural Inflammation

    Science.gov (United States)

    Volz, Kevin R.

    Molecular imaging is a form of nanotechnology that enables the noninvasive examination of biological processes in vivo. Radiopharmaceutical agents are used to selectively target biochemical markers, which permits their detection and evaluation. Early visualization of molecular variations indicative of pathophysiological processes can aid in patient diagnoses and management decisions. Molecular imaging is performed by introducing molecular probes into the body. Molecular probes are often contrast agents that have been nanoengineered to selectively target and tether to molecules, enabling their radiologic identification. Ultrasound contrast agents have been demonstrated as an effective method of detecting perfusion at the tissue level. Through a nanoengineering process, ultrasound contrast agents can be targeted to specific molecules, thereby extending ultrasound's capabilities from the tissue to molecular level. Molecular ultrasound, or targeted contrast enhanced ultrasound (TCEUS), has recently emerged as a popular molecular imaging technique due to its ability to provide real-time anatomical and functional information in the absence of ionizing radiation. However, molecular ultrasound represents a novel form of molecular imaging, and consequently remains largely preclinical. A review of the TCEUS literature revealed multiple preclinical studies demonstrating its success in detecting inflammation in a variety of tissues. Although, a gap was identified in the existing evidence, as TCEUS effectiveness for detection of neural inflammation in the spinal cord was unable to be uncovered. This gap in knowledge, coupled with the profound impacts that this TCEUS application could have clinically, provided rationale for its exploration, and use as contributory evidence for the molecular ultrasound body of literature. An animal model that underwent a contusive spinal cord injury was used to establish preclinical evidence of TCEUS to detect neural inflammation. Imaging was

  8. Stable phantom materials for ultrasound and optical imaging

    Science.gov (United States)

    Cabrelli, Luciana C.; Pelissari, Pedro I. B. G. B.; Deana, Alessandro M.; Carneiro, Antonio A. O.; Pavan, Theo Z.

    2017-01-01

    Phantoms mimicking the specific properties of biological tissues are essential to fully characterize medical devices. Water-based materials are commonly used to manufacture phantoms for ultrasound and optical imaging techniques. However, these materials have disadvantages, such as easy degradation and low temporal stability. In this study, we propose an oil-based new tissue-mimicking material for ultrasound and optical imaging, with the advantage of presenting low temporal degradation. A styrene-ethylene/butylene-styrene (SEBS) copolymer in mineral oil samples was made varying the SEBS concentration between 5%-15%, and low-density polyethylene (LDPE) between 0%-9%. Acoustic properties, such as the speed of sound and the attenuation coefficient, were obtained using frequencies ranging from 1-10 MHz, and were consistent with that of soft tissues. These properties were controlled varying SEBS and LDPE concentration. To characterize the optical properties of the samples, the diffuse reflectance and transmittance were measured. Scattering and absorption coefficients ranging from 400 nm-1200 nm were calculated for each compound. SEBS gels are a translucent material presenting low optical absorption and scattering coefficients in the visible region of the spectrum, but the presence of LDPE increased the turbidity. Adding LDPE increased the absorption and scattering of the phantom materials. Ultrasound and photoacoustic images of a heterogeneous phantom made of LDPE/SEBS containing a spherical inclusion were obtained. Annatto dye was added to the inclusion to enhance the optical absorbance. The results suggest that copolymer gels are promising for ultrasound and optical imaging, making them also potentially useful for photoacoustic imaging.

  9. Stable phantom materials for ultrasound and optical imaging.

    Science.gov (United States)

    Cabrelli, Luciana C; Pelissari, Pedro I B G B; Deana, Alessandro M; Carneiro, Antonio A O; Pavan, Theo Z

    2017-01-21

    Phantoms mimicking the specific properties of biological tissues are essential to fully characterize medical devices. Water-based materials are commonly used to manufacture phantoms for ultrasound and optical imaging techniques. However, these materials have disadvantages, such as easy degradation and low temporal stability. In this study, we propose an oil-based new tissue-mimicking material for ultrasound and optical imaging, with the advantage of presenting low temporal degradation. A styrene-ethylene/butylene-styrene (SEBS) copolymer in mineral oil samples was made varying the SEBS concentration between 5%-15%, and low-density polyethylene (LDPE) between 0%-9%. Acoustic properties, such as the speed of sound and the attenuation coefficient, were obtained using frequencies ranging from 1-10 MHz, and were consistent with that of soft tissues. These properties were controlled varying SEBS and LDPE concentration. To characterize the optical properties of the samples, the diffuse reflectance and transmittance were measured. Scattering and absorption coefficients ranging from 400 nm-1200 nm were calculated for each compound. SEBS gels are a translucent material presenting low optical absorption and scattering coefficients in the visible region of the spectrum, but the presence of LDPE increased the turbidity. Adding LDPE increased the absorption and scattering of the phantom materials. Ultrasound and photoacoustic images of a heterogeneous phantom made of LDPE/SEBS containing a spherical inclusion were obtained. Annatto dye was added to the inclusion to enhance the optical absorbance. The results suggest that copolymer gels are promising for ultrasound and optical imaging, making them also potentially useful for photoacoustic imaging.

  10. Oil-based gel phantom for ultrasound and optical imaging

    Science.gov (United States)

    Cabrelli, Luciana C.; Pelissari, Pedro I. B. G. B.; Aggarwal, Lucimara P.; Deana, Alessandro M.; Carneiro, Antonio A. O.; Pavan, Theo. Z.

    2015-06-01

    Water-based materials are commonly used in phantoms for ultrasound and optical imaging techniques. However, these materials have disadvantages such as easy degradation and low temporal stability. In this study, we propose an oil-based new tissue mimicking material for ultrasound and optical imaging, with the advantage of presenting low temporal degradation. Styrene-Ethylene/Butylene-Styrene (SEBS) copolymer in mineral oil samples were made varying the SEBS concentration between 5-15%, and low-density polyethylene (LDPE) between 0-9%. Acoustic properties such as speed of sound and attenuation coefficient were obtained by the substitution technique with frequencies ranging from 2.25-10 MHz, and were consistent to that of soft tissue. These properties were controlled varying SEBS and LDPE concentration; speed of sound from 1445-1480 m/s, and attenuation from 0.86-11.31 dB/cm were observed. SEBS gels with 0% of LDPE were optically transparent, presenting low optical absorption and scattering coefficients in the visible region of the spectrum. In order to fully characterize the optical properties of the samples, the reflectances of the surfaces were measured, along with the absorption. Scattering and absorption coefficients ranging from 400 nm to 1200 nm were calculated for each compound. The results showed that the presence of LDPE increased absorption and scattering of the phantoms. The results suggest the copolymer gels are promising for ultrasound and optical imaging, what make them also potentially useful for photoacoustic imaging.

  11. Ultrasound imaging accurately identifies the intercostobrachial nerve

    Directory of Open Access Journals (Sweden)

    Ahmed K. Thallaj

    2015-10-01

    Full Text Available Objectives: To test the hypothesis that identification and blockade of the intercostobrachial nerve (ICBN can be achieved under ultrasound (US guidance using a small volume of local anesthetic. Methods: Twenty-eight adult male volunteers were examined at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia from November 2012 to September 2013. Intercostobrachial nerve blockade was performed using one ml of 2% lidocaine under US guidance. A sensory map of the blocked area was developed relative to the medial aspect of the humeral head. Results: The ICBN appears as a hyper-echoic structure. The nerve diameter was 2.3±0.28 mm, and the depth was 9±0.28 mm. The measurements of the sensory-blocked area relative to the medial aspect of the humeral head were as follows: 6.3±1.6 cm anteriorly; 6.2±2.9 cm posteriorly; 9.4±2.9 cm proximally; and 9.2±4.4 cm distally. Intercostobrachial nerve blockade using one ml of local anesthetic was successful in all cases. Conclusion: The present study described the sonographic anatomical details of the ICBN and its sensory distribution to successfully perform selective US-guided ICBN blockade.

  12. Review of Laser-Generated Ultrasound Transmitters and Their Applications to All-Optical Ultrasound Transducers and Imaging

    Directory of Open Access Journals (Sweden)

    Sung-Liang Chen

    2016-12-01

    Full Text Available Medical ultrasound is an imaging technique that utilizes ultrasonic signals as information carriers, and has wide applications such as seeing internal body structures, finding a source of a disease, and examining pregnant women. The most commonly used ultrasonic transducer today is based on piezoelectricity. The piezoelectric transducer, however, may have a limited bandwidth and insufficient sensitivity for reduced element size. Laser-generated ultrasound (LGUS technique is an effective way to resolve these issues. The LGUS approach based on photoacoustic effect is able to greatly enhance the bandwidth of ultrasound signals and has the potential for high-resolution imaging. High-amplitude LGUS could also be used for therapy to accomplish high precision surgery without an incision. Furthermore, LGUS in conjunction with optical detection of ultrasound allows all-optical ultrasound imaging (i.e., ultrasound is generated and received optically. The all-optical platform offers unique advantages in providing high-resolution information and in facilitating the construction of miniature probes for endoscopic ultrasound. In this article, a detailed review of the recent development of various LGUS transmitters is presented. In addition, a recent research interest in all-optical ultrasound imaging, as well as its applications, is also discussed.

  13. Echo decorrelation imaging of ex vivo HIFU and bulk ultrasound ablation using image-treat arrays

    Science.gov (United States)

    Fosnight, Tyler R.; Hooi, Fong Ming; Colbert, Sadie B.; Keil, Ryan D.; Barthe, Peter G.; Mast, T. Douglas

    2017-03-01

    In this study, the ability of ultrasound echo decorrelation imaging to map and predict heat-induced cell death was tested using bulk ultrasound thermal ablation, high intensity focused ultrasound (HIFU) thermal ablation, and pulse-echo imaging of ex vivo liver tissue by a custom image-treat array. Tissue was sonicated at 5.0 MHz using either pulses of unfocused ultrasound (N=12) (7.5 s, 50.9-101.8 W/cm2 in situ spatial-peak, temporal-peak intensity) for bulk ablation or focused ultrasound (N=21) (1 s, 284-769 W/cm2 in situ spatial-peak, temporal-peak intensity and focus depth of 10 mm) for HIFU ablation. Echo decorrelation and integrated backscatter (IBS) maps were formed from radiofrequency pulse-echo images captured at 118 frames per second during 5.0 s rest periods, beginning 1.1 s after each sonication pulse. Tissue samples were frozen at -80˚C, sectioned, vitally stained, imaged, and semi-automatically segmented for receiver operating characteristic (ROC) analysis. ROC curves were constructed to assess prediction performance for echo decorrelation and IBS. Logarithmically scaled mean echo decorrelation in non-ablated and ablated tissue regions before and after electronic noise and motion correction were compared. Ablation prediction by echo decorrelation and IBS was significant for both focused and bulk ultrasound ablation. The log10-scaled mean echo decorrelation was significantly greater in regions of ablation for both HIFU and bulk ultrasound ablation. Echo decorrelation due to electronic noise and motion was significantly reduced by correction. These results suggest that ultrasound echo decorrelation imaging is a promising approach for real-time prediction of heat-induced cell death for guidance and monitoring of clinical thermal ablation, including radiofrequency ablation and HIFU.

  14. [A three-dimensional transrectal ultrasound imaging system].

    Science.gov (United States)

    Chen, Yimin; Qi, Jian; Ding, Mingyue; Zhang, Xuming

    2014-08-01

    A three-dimensional (3D) transrectal ultrasound (TRUS) imaging system is presented in this paper. The 3D imaging system is used for diagnosing diseases of prostate. The 3D image is reconstructed by a series of two-dimensional image data which is obtained through rectum. It can be a guide to prostate needle biopsies. The system is built by two parts: hardware and software. In the hardware, the mechanical device, stepper motor, control circuit, B Mode TRUS and personal computer (PC) workshop are presented. The software includes the firmware of micro control unit and software of the PC workshop. In order to evaluate the performance of the 3D imaging system, we did experiments with water and agar phantoms, and the results demonstrated the system's ability of 3D imaging with high-precision.

  15. Model-Based Reconstructive Elasticity Imaging Using Ultrasound

    Directory of Open Access Journals (Sweden)

    Salavat R. Aglyamov

    2007-01-01

    Full Text Available Elasticity imaging is a reconstructive imaging technique where tissue motion in response to mechanical excitation is measured using modern imaging systems, and the estimated displacements are then used to reconstruct the spatial distribution of Young's modulus. Here we present an ultrasound elasticity imaging method that utilizes the model-based technique for Young's modulus reconstruction. Based on the geometry of the imaged object, only one axial component of the strain tensor is used. The numerical implementation of the method is highly efficient because the reconstruction is based on an analytic solution of the forward elastic problem. The model-based approach is illustrated using two potential clinical applications: differentiation of liver hemangioma and staging of deep venous thrombosis. Overall, these studies demonstrate that model-based reconstructive elasticity imaging can be used in applications where the geometry of the object and the surrounding tissue is somewhat known and certain assumptions about the pathology can be made.

  16. Ultrasound imaging in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Christo Naveen Prince

    2012-01-01

    Full Text Available Background and Objectives: To assess the diagnostic capability of real-time ultrasound imaging, together with the application of color power Doppler in the identification and differential diagnosis of the periapical lesions. Materials and Methods: Fifteen patients with periapical lesions of pulpal origin, diagnosed with clinical and conventional radiographic examination, were examined further using ultrasonography. The results from the biopsies of the lesions were compared and statistically analyzed. Results: The differential diagnosis between periapical granulomas and cystic lesions, which were based on the ultrasonographic findings, were confirmed by the results of the histopathologic examination in 13 (86.7% of 15 cases, one being granuloma and 14 being cystic lesion. Interpretation and Conclusion: Ultrasound real-time imaging is a technique that may help make a differential diagnosis between cysts and granulomas by revealing the nature of the content of a bony lesion. This technique may have further applications in the study of other lesions of the jaws.

  17. Development of a hybrid magnetic resonance and ultrasound imaging system.

    Science.gov (United States)

    Sherwood, Victoria; Civale, John; Rivens, Ian; Collins, David J; Leach, Martin O; ter Haar, Gail R

    2014-01-01

    A system which allows magnetic resonance (MR) and ultrasound (US) image data to be acquired simultaneously has been developed. B-mode and Doppler US were performed inside the bore of a clinical 1.5 T MRI scanner using a clinical 1-4 MHz US transducer with an 8-metre cable. Susceptibility artefacts and RF noise were introduced into MR images by the US imaging system. RF noise was minimised by using aluminium foil to shield the transducer. A study of MR and B-mode US image signal-to-noise ratio (SNR) as a function of transducer-phantom separation was performed using a gel phantom. This revealed that a 4 cm separation between the phantom surface and the transducer was sufficient to minimise the effect of the susceptibility artefact in MR images. MR-US imaging was demonstrated in vivo with the aid of a 2 mm VeroWhite 3D-printed spherical target placed over the thigh muscle of a rat. The target allowed single-point registration of MR and US images in the axial plane to be performed. The system was subsequently demonstrated as a tool for the targeting and visualisation of high intensity focused ultrasound exposure in the rat thigh muscle.

  18. Development of a Hybrid Magnetic Resonance and Ultrasound Imaging System

    Directory of Open Access Journals (Sweden)

    Victoria Sherwood

    2014-01-01

    Full Text Available A system which allows magnetic resonance (MR and ultrasound (US image data to be acquired simultaneously has been developed. B-mode and Doppler US were performed inside the bore of a clinical 1.5 T MRI scanner using a clinical 1–4 MHz US transducer with an 8-metre cable. Susceptibility artefacts and RF noise were introduced into MR images by the US imaging system. RF noise was minimised by using aluminium foil to shield the transducer. A study of MR and B-mode US image signal-to-noise ratio (SNR as a function of transducer-phantom separation was performed using a gel phantom. This revealed that a 4 cm separation between the phantom surface and the transducer was sufficient to minimise the effect of the susceptibility artefact in MR images. MR-US imaging was demonstrated in vivo with the aid of a 2 mm VeroWhite 3D-printed spherical target placed over the thigh muscle of a rat. The target allowed single-point registration of MR and US images in the axial plane to be performed. The system was subsequently demonstrated as a tool for the targeting and visualisation of high intensity focused ultrasound exposure in the rat thigh muscle.

  19. Ultrasound Biomicroscopy in Small Animal Research: Applications in Molecular and Preclinical Imaging

    OpenAIRE

    Greco, A.; Mancini, M.; Gargiulo, S; Gramanzini, M.; Claudio, P. P.; Brunetti, A; Salvatore, . M

    2011-01-01

    Ultrasound biomicroscopy (UBM) is a noninvasive multimodality technique that allows high-resolution imaging in mice. It is affordable, widely available, and portable. When it is coupled to Doppler ultrasound with color and power Doppler, it can be used to quantify blood flow and to image microcirculation as well as the response of tumor blood supply to cancer therapy. Target contrast ultrasound combines ultrasound with novel molecular targeted contrast agent to assess biological processes at ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...