WorldWideScience

Sample records for subclavian artery punctures

  1. J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system

    International Nuclear Information System (INIS)

    Hama, Yukihiro; Kusano, Shoichi; Makita, Kohzoh

    2004-01-01

    The aim of this study was to verify the feasibility of using a J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system (RPCS). Twenty-five patients with various hepatic malignancies underwent percutaneous implantation of an RPCS through the left subclavian artery for regional chemotherapy. To successfully puncture the left subclavian artery, a J-tipped guidewire was used as a target with fluoroscopic guidance. Technical success and complication rates, and numbers of puncture failures, were retrospectively analyzed. Implantation of the RPCS was successful in all patients. Eight (32%) patients had minor complications and no patient had major complications. The number of puncture failures per patient was 0 to 1 (mean=0.32). The J-tipped guidewire is a safe and appropriate target for puncture of the subclavian artery in the placement of an RPCS. (orig.)

  2. Stenting-plasty with brachial puncture in the treatment of subclavian steal syndrome

    International Nuclear Information System (INIS)

    Chen Quan; Jing Zaiping; Zhao Zhiqing; Feng Xiang; Lu Qingsheng; Mei Zhijun

    2007-01-01

    Objective: To study the clinical effect of stenting-plasty with retrograde brachial puncture for subclavian steal syndrome patients. Methods: To analyze the clinical results of stenting-plasty with retrograde brachial puncture in 15 patients with subclavian steal syndrome. Results: MRA or DSA showed the subclavian arteries with different degrees of stenosis (80%-100%) in all patients. Stenting-plasty with retrograde brachia] puncture was used in all patients. After placement of wall or polmaz stent, the pulse recovered and the syndrome disappeared. Postoperative angiography showed patency of the artery and stent. The patients were followed up for 3-30 months without recurrence of symptoms. Conclusions: Stenting-plasty with retrograde brachial puncture is a rather proper method to treat subclavian steal syndrome with more coincidence to the vascular anatomy, decrease the maneuver trouble and increase the successful rate. (authors)

  3. Closure Using a Surgical Closure Device of Inadvertent Subclavian Artery Punctures During Central Venous Catheter Placement

    International Nuclear Information System (INIS)

    Berlet, Matthew H.; Steffen, Diana; Shaughness, George; Hanner, James

    2001-01-01

    Severe complications can and do occur when central venous catheters are inadvertently placed into subclavian arteries. Two cases are discussed that describe how these inadvertent arterial punctures can be closed using the Perclose device (Abbott Laboratories, Redwood City, CA, USA)

  4. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  5. INTERNAL BALLOON TAMPONADE - A NONSURGICAL METHOD FOR REMOVAL OF ACCIDENTALLY PLACED SHEATHS FROM THE SUBCLAVIAN ARTERY

    NARCIS (Netherlands)

    VANDIJK, RB; DENHEIJER, P; DEMUINCK, E; LIE, KI

    One of the possible complications of subclavian vein puncture is accidental puncture of the subclavian artery. If this is not noted immediately after the puncture, insertion of a large bore sheath in the subclavian artery is likely to follow. We describe our experience with a new method that enables

  6. Endovascular Treatment of an Iatrogenic Right Internal Jugular Vein- Right Subclavian Artery Fistula and Pseudoaneurysm During the Attempt of a Hemodialysis Catheter Insertion: A Case Report

    International Nuclear Information System (INIS)

    Cho, Eui Min; Kim, Hyun Lee; Kim, Dong Hyun

    2009-01-01

    Complications during the placement of a central venous catheter, via the right internal jugular vein puncture include local hematoma, hemothorax, pneumothorax, central vein thrombosis, and hemopericardium. Iatrogenic right internal jugular vein-right subclavian artery fistula with the formation of right subclavian artery pseudoaneurysms is an extremely rare complication in patients undergoing a central vein puncture. We report the case of a patient who developed a local hematoma at the vein puncture site and dyspnea due to a right internal jugular vein-subclavian artery fistula and a right subclavian artery pseudoaneurysm at the mediastinum after puncture of right internal jugular vein. The patient was successfully treated by embolization using microcoils

  7. Partial subclavian steal syndrome in a congenitally anomalous subclavian artery

    International Nuclear Information System (INIS)

    Krnic, A.; Sucic, Z.; Vucic, N.; Krolo, I.

    2006-01-01

    Background. A subclavian steal syndrome results from the abnormal flow of blood due to the occlusion in the subclavian artery proximal to the origin of the vertebral artery. A case of a male patient with a partial subclavian steal syndrome is presented. Case report. The syndrome was caused by a stenotic lesion of an aberrant right subclavian artery (the so called lusorian artery). The partial subclavian steal was recognized using the duplex ultrasound which showed the to and fro pattern in the right vertebral artery. Angiography of the aortic arch revealed the arterial anomaly. In our case, duplex ultrasound was a crucial method in diagnosing the partial subclavian steal syndrome. However, in order to show the arterial anomaly, the final evaluation had to be performed using arteriography. Conclusions. The early recognized partial subclavian steal syndrome provides good understanding of patient's symptoms, successful follow up, and a variety of treatment options. (author)

  8. Use of a Puncture Needle for Recanalization of an Occluded Right Subclavian Vein

    International Nuclear Information System (INIS)

    Gupta, Himanshu; Murphy, Timothy P.; Soares, Gregory M.

    1998-01-01

    We report a patient in whom we used a puncture needle to initiate percutaneous recanalization of a chronic occlusion of the junction between the right subclavian vein and the right brachiocephalic vein. Under fluoroscopic guidance, an 18-gauge needle was used to puncture the right subclavian vein. When contrast material injected through the needle confirmed intravascular location, the needle was advanced until it deflected and perforated an occlusion balloon target positioned within the right brachiocephalic vein. This technique may be useful in patients with central venous occlusions that are refractory to traversal using traditional catheter and guidewire techniques

  9. Validation of subclavian duplex velocity criteria to grade severity of subclavian artery stenosis.

    Science.gov (United States)

    Mousa, Albeir Y; Morkous, Ramez; Broce, Mike; Yacoub, Michael; Sticco, Andrew; Viradia, Ravi; Bates, Mark C; AbuRahma, Ali F

    2017-06-01

    Validation of subclavian duplex ultrasound velocity criteria (SDUS VC) to grade the severity of subclavian artery stenosis has not been established or systematically studied. Currently, there is a paucity of published literature and lack of practitioner consensus for how subclavian duplex velocity findings should be interpreted in patients with subclavian artery stenosis. The objective of the present study was to validate SDUS measurements using subclavian conventional or computed tomography angiogram (subclavian angiogram [SA])-derived measurements. Secondary objectives included measuring the correlation between SDUS peak systolic velocities and SA measurements, and to determine the optimal cutoff value for predicting significant stenosis (>70%). This is a retrospective review of all patients with suspected subclavian artery stenosis and a convenience sample of carotid artery patients who underwent SDUS and SA from May 1999 to July 2013. SA reference vessel and intralesion minimal lumen diameters were measured and compared with SDUS velocities obtained within 3 months of the imaging study. Percent stenosis was calculated using the North American Symptomatic Carotid Endarterectomy Trial method for detecting stenosis in a sufficiently large cohort. Receiver operating characteristic curves was generated for SDUS VC to predict >70% stenosis. Velocity cutoff points were determined with equal weighting of sensitivity and specificity. We examined 268 arteries for 177 patients. The majority of the arteries were for female patients (52.5%) with a mean age of 66.7 ± 11.1 years. Twenty-three arteries had retrograde vertebral artery flow and excluded from further analysis. For the remaining 245 arteries, the average peak systolic velocity was 212.6 ± 110.7 cm/s, with a range of 45-626 cm/s. Average stenosis was 25.8% ± 28.2%, with a range of 0% to 100%. Following receiver operating characteristic analysis, we found a cutoff value of >240 cm/s to be most predictive

  10. An isolated left subclavian artery supplied by a collateral artery from the abdominal aorta

    International Nuclear Information System (INIS)

    Ming, Zhu; Qian, Wang

    2009-01-01

    An isolated left subclavian artery is a rare anomaly. We report a 9-month-old boy with an isolated left subclavian artery associated with tetralogy of Fallot and the right aortic arch. MRI and angiography show that the blood supply through the left subclavian artery was maintained by a large tortuous collateral artery from the abdominal aorta. This type of collateral artery structure is unique. (orig.)

  11. An isolated left subclavian artery supplied by a collateral artery from the abdominal aorta

    Energy Technology Data Exchange (ETDEWEB)

    Ming, Zhu; Qian, Wang [Shanghai Jiaotong University School of Medicine, Department of Radiology, Shanghai Children' s Medical Center, Shanghai (China)

    2009-08-15

    An isolated left subclavian artery is a rare anomaly. We report a 9-month-old boy with an isolated left subclavian artery associated with tetralogy of Fallot and the right aortic arch. MRI and angiography show that the blood supply through the left subclavian artery was maintained by a large tortuous collateral artery from the abdominal aorta. This type of collateral artery structure is unique. (orig.)

  12. Retroesophageal right subclavian artery: a case report and review of ...

    African Journals Online (AJOL)

    Retroesophageal right subclavian artery: a case report and review of the literature. Anthony Ocaya. Department ... the left subclavian artery, and the left common carotid artery. Adachi first .... Vol 2, New York: Harper & Row. 1968. 13. Tubbs SR ...

  13. Primary Stenting of Subclavian and Innominate Artery Occlusive Disease: A Single Center's Experience

    International Nuclear Information System (INIS)

    Brountzos, E. N.; Petersen, B.; Binkert, C.; Panagiotou, I.; Kaufman, J. A.

    2004-01-01

    Purpose: To review immediate and midterm results of primary stenting for innominate and subclavian artery occlusive lesions. Methods: Retrospective data were collected from 48 consecutive symptomatic patients (27 men and 21 women, median age 64 years) having 49 subclavian and innominate artery lesions treated with stenting. Of the patients 52% had concomitant ischemic heart disease, and 30% had carotid and/or vertebral artery disease. Indication for treatment was vertebrobasilar insufficiency (VBI) in 16.6% of the patients; upper limb ischemia (ULI) in 31.3%; VBI and ULI in 12.5%; transient ischemic attack in 16.7%; angina in 12.5% before or after left internal mammary artery-to-coronary artery bypass grafting; and leg claudication in 10.4% before or after axillofemoral bypass grafting. Balloon-expandable stents were used in 44 lesions and self-expandable stents in 5 lesions. In total, 53 stents were placed in 48 patients. Results: Technical success was 96%, and clinical success 94%. We encountered four complications (two puncture site hematomas, one distal hand embolization and one transient cerebral ischemia). Two patients died within 30 days from other causes, and seven patients were lost to follow-up. Mean follow-up time was 16.7 months (range 0.3 to 68.2). Five patients had recurrent lesions treated by surgical (n = 2) or endovascular (n = 3) means. Cumulative primary patency rate was 91.7% and 77% at 12 and 24 months, respectively. Cumulative secondary patency rate was 96.5% and 91.7% at 12 and 24 months, respectively. Conclusion: Stenting of subclavian and innominate artery lesions resulted in immediate resolution of patients' symptoms with durable midterm effect and few complications in a larger patient group with serious comorbid conditions

  14. Retroesophageal right subclavian artery: A case report and review ...

    African Journals Online (AJOL)

    Background: Variations of vessels arising from the aortic arch are numerous. One of the common anatomical variations is the right subclavian artery originating as the last branch of the aortic arch. This is a report of a case of an adult male cadaver with a retroesophageal right subclavian artery. Objective: To highlight the ...

  15. Right cervical aortic arch with aberrant left subclavian artery.

    Science.gov (United States)

    Tjang, Yanto S; Aramendi, José I; Crespo, Alejandro; Hamzeh, Gadah; Voces, Roberto; Rodríguez, Miguel A

    2008-08-01

    The combination of right cervical aortic arch, aberrant retroesophageal left subclavian artery originating from a Kommerell's diverticulum, and a ligamentum arteriosum, constitutes a rare form of vascular ring. Two patients aged 21 days and 54 years, who were diagnosed by multislice 3-dimensional computed tomography and magnetic resonance imaging, underwent surgical division of a vascular ring. The adult required resection of a Kommerell's aneurysm and subclavian artery reimplantation.

  16. [Coronary subclavian steal syndrome: two cases after coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Penninga, L.; Damgaard, S.

    2008-01-01

    Reverse flow in the internal mammary artery (IMA) graft due to stenosis or occlusion of the proximal ipsilateral subclavian artery causes coronary subclavian steal syndrome (CSSS). We describe two patients who were diagnosed with CSSS following CABG. Patient A presented with angina pectoris...

  17. Applications and complications of subclavian vein catheterization for hemodialysis

    International Nuclear Information System (INIS)

    Kamran, T.; Zaheer, K.; Khan, A.A.; Khalid, M.; Akhtar, M.S.

    2003-01-01

    Objective: To study the indications, complications and duration of 605 subclavian catheters inserted over a period of 4 years as venous access for the management of renal failure in local setup. Results: Among the patients who underwent subclavian vien catheterization, 75.2% patients were suffering from chronic renal failure and 24.7% patients were admitted for acute renal failure. Among chronic renal failure patients, 21.9% catheters had to be replaced due to various complications e.g. thrombosis, infection or kinking of the catheter. The subclavian catheters remained in place for a mean duration of 4 weeks. Early complications encountered were arterial puncture, inability to cannulate the innominate vein, hemo thorax, punctures of thoracic duct, hemo mediastinum, arrhythmias and pulmonary hematoma in 10.7%, 16.5%, 0.5%, 0.2%, 0.6% and 0.2% of patients respectively. Mortality attributed to the procedure occurred in 0.1 % cases. Delayed complications included early infection in 15% catheterizations while delayed infection occurred in 39 % cases. Conclusion: Percutaneous subclavian catheterization is valuable, relatively easy to learn and safe method with acceptable rate of complications for patients necessitating hemodialysis and no established permanent vascular access. (author)

  18. Refractory Hypotension as an Initial Presentation of Bilateral Subclavian Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Maxwell Eyram Afari

    2016-01-01

    Full Text Available Bilateral subclavian stenosis is a rare clinical condition. An interbrachial pressure difference of 15 mm Hg can raise suspicion for unilateral subclavian artery stenosis, but the diagnosis of bilateral subclavian artery stenosis can be challenging. We present a case of a 75-year-old woman who presented with refractory hypotension after surgery. Initial vitals revealed blood pressure in the 60s/50s mm Hg in both arms. Cardiopulmonary examination was remarkable for diminished pulses in all 4 extremities and audible carotid bruits. She continued to be hypotensive despite aggressive fluid resuscitation. Troponin T peaked at 0.24 ng/mL (reference < 0.04, and an echocardiogram revealed a reduction in ejection fraction (37% from 50%. Left and right heart catheterization demonstrated normal filling pressures and cardiac output. During the procedure, however, it was noted that the patient’s central blood pressure was 70–80 mm Hg higher than cuff pressures obtained in either arm. Selective angiography revealed 90% left subclavian ostial stenosis as well as 70% stenosis of the right subclavian artery.

  19. A Rare Entity: Traumatic Thoracic Aortic Injury in a Patient with Aberrant Right Subclavian Artery.

    Science.gov (United States)

    Patel, Hiten Mohanbhai; Banerjee, Shubhabrata; Bulsara, Shahzad; Sahu, Tapish; Sheorain, Virender K; Grover, Tarun; Parakh, Rajiv

    2017-05-01

    Aberrant right subclavian artery is an uncommon entity incidence ranging from 0.5 to 2.5%. Management of thoracic aortic injury in the presence of such anomalies can be a challenge. We present here a case of traumatic aortic injury, which was incidentally found to have an asymptomatic aberrant right subclavian artery. The patient was managed by an endovascular repair of thoracic aortic injury with an endograft and a right carotid to subclavian artery bypass as a hybrid procedure. A 40-year male patient was brought to the emergency in shock with an alleged history of road traffic accident an hour back. After initial resuscitation as per advance trauma life support protocol, imaging revealed thoracic aortic injury with aberrant right subclavian artery with multiple rib and bilateral humerus fracture. After primary stabilization of arm fractures, the patient was shifted to a hybrid operation room. As the aortic injury was within 10 mm of the origin of both subclavian arteries, it was decided to cover the origin of both subclavian arteries and land the endograft distal to the left carotid artery origin. Since there was a right dominant vertebral artery on imaging, right carotid to right subclavian artery bypass was done with expanded polytetrafluoroethylene graft to prevent posterior circulatory stroke along with thoracic endovascular aortic repair to seal the thoracic aortic injury. After endovascular repair of thoracic aortic injury, left subclavian artery perfusion was maintained through left vertebral artery; and hence, revascularization of left subclavian artery was deferred. After management of all fractures, the patient was discharged 3 weeks after the date of admission without any complications. At 6 months follow-up, patient was stable and images showed patent bypass graft and sealed aortic injury. In a trauma setting with multiple injuries, hybrid procedure with a thoracic endograft is associated with low mortality and morbidity; hence, it is the treatment

  20. Subclavian artery dissection during diagnostic cardiac catheterization: the role of conservative management.

    Science.gov (United States)

    Frohwein, S; Ververis, J J; Marshall, J J

    1995-04-01

    Dissection of the subclavian artery during routine cardiac catheterization while obtaining cannulation to the left internal mammary artery is an unusual complication and to our knowledge has never been reported. Conservative management of this vascular injury can avoid the sequelae of high-risk surgical repairs made difficult by a complex operative exposure. We describe a case in which dissection of the left subclavian artery was treated conservatively with an excellent outcome.

  1. Percutaneous endovascular therapy for symptomatic chronic total occlusion of the left subclavian artery.

    Science.gov (United States)

    Akif Cakar, Mehmet; Tatli, Ersun; Tokatli, Alptug; Kilic, Harun; Gunduz, Huseyin; Akdemir, Ramazan

    2018-03-16

    Percutaneous endovascular therapy is an accepted and preferred procedure for symptomatic subclavian artery disease. However, the technical feasibility and effectiveness of treating chronic total occlusion of the subclavian artery with this approach is uncertain. We aimed to evaluate the initial and mid-term results of endovascular therapy for patients with symptomatic chronic total occlusion of the left subclavian artery. Consecutive patients who underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery between January 2010 and February 2014 were included. Overall, 16 patients (10 male, 6 female; mean age 56 ± 13 years) underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery - 6 (37.5%) had arm claudication, 8 (50.0%) had vertebrobasilar insufficiency and 2 (12.5%) had coronary steal. 18 balloon-expandable stents were implanted to 15 patients. The central luminal passage was not achieved in one patient because of the subintimal position of guidewire (procedural success rate 93.8%). There were no procedure-related complications. Mean preprocedural and postprocedural systolic blood pressure differences between the upper extremities were 37 ± 13 (range 25-60) mmHg and 11 ± 9 (range 5-38) mmHg, respectively; the improvement was statistically significant. Outpatient follow-up revealed one asymptomatic restenosis at two years. Patency rate at two years was 93.3%. Balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery is safe and effective, with good acute success rate and mid-term patency. Prospective randomised studies on larger patient populations would provide more precise results.

  2. Arterial reconstruction of the brachiocephalic trunk and the subclavian arteries. 10 years' experience with a follow-up study

    DEFF Research Database (Denmark)

    Schroeder, T; Hansen, Hans Jørgen Buchardt

    1980-01-01

    During a 10-year period, 60 patients were operated on for occlusive lesions in the brachiocephalic trunk and/or the subclavian arteries proximal to the vertebral artery. Angiography showed 68 occlusive lesions, of which 64 were treated surgically. Of these, 47 exhibited subclavian steal. Sixty...

  3. Anatomical Arrangement of the Subclavian Artery Branches in the Rabbit and European Hare

    Directory of Open Access Journals (Sweden)

    Maženský D.

    2017-12-01

    Full Text Available The aim of this study was to compare the anatomical arrangements of the branches arising from the subclavian arteries in the domesticated rabbit and hare. The study was carried out on ten adult rabbits and ten adult European hares using the corrosion cast technique. After the euthanasia, the vascular network was perfused with saline. The arterial system of the entire body was injected by Batson’s corrosion casting kit No. 17. After polymerization of the medium, the maceration was carried out in KOH solution. The arrangement of the origins of the branches of the bilateral subclavian arteries were more variable in the hare. The number of branches arising from the subclavian artery were more regular in the rabbit on the right side and in the hare on the left side. In the rabbit, we found in two cases, the origins of the branches of the left subclavian artery from the aortic arch. The anatomical found between the rabbit and the hare may possibly be associated with their different ways of life.

  4. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2016-01-01

    Full Text Available We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  5. Doppler Ultrasonography in Suspected Subclavian Artery Obstruction and in Patient Monitoring after Subclavian Stenting

    International Nuclear Information System (INIS)

    Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Pieniazek, Piotr; Musialek, Piotr; Kozanecki, Artur; Stopa, Ireneusz; Zalewski, Jaroslaw; Tracz, Wieslawa

    2007-01-01

    Purpose. Subclavian or innominate artery (SIA) stenosis affects up to 5% of patients referred to coronary bypass grafting; it is symptomatic in less than half of these. This study aimed to assess the Doppler ultrasonography (DU) findings in SIA obstruction and patients' follow-up after percutaneous angioplasty (PTA). Methods. The study enrolled 118 patients (68 men, 50 women), aged 61.3 ± 8.7 years, with suspected SIA obstruction, in whom peak systolic velocity (PSV) in the SIA and subclavian steal grade were assessed on DU and verified by quantitative angiography (QA). Serial follow-up DU was performed in patients treated with PTA. Results. Grade I-III of subclavian steal from the vertebral artery (VA) was found in 89.8% of patients. In the remaining 10.2% only a PSV increase in the SIA was observed. QA confirmed the presence of SIA obstruction in all patients (stenosis grade: 80.9 ± 17.3%). In patients with one-sided SIA obstruction, the ultrasonographic steal grade correlated with the QA stenosis grade (p < 0.001, r = 0.648). Lack of subclavian steal was noted in the case of distal subclavian stenosis, VA obstruction, VA originating from the aortic arch, and bilateral SIA obstruction. Successful PTA was performed in 77 of 83 patients referred to that procedure. PSV was reduced from 4.4 ± 1.2 (2.2-6.5) m/sec to 1.34 ± 0.51 (0.5-2.5) m/sec and flow in the VA was normalized. During the mean follow-up time of 24.7 ± 15.6 months, there was a gradual increase in the in-stent PSV as well as gradual VA flow alterations, resulting in symptom recurrence. More than a twofold PSV increase, compared with the post-PTA values, was an indicator of restenosis in 11 of 12 patients. Conclusions. Careful DU evaluation enables the recognition of SIA obstruction in all patients. Ninety percent of them have subclavian steal correlating with the stenosis grade. Restenosis can be reliably detected with DU based on in-stent PSV and VA flow alterations

  6. RIGHT-SIDED AORTIC ARCH WITH ABERRANT LEFT SUBCLAVIAN ARTERY AND DUPLICATION OF SUPERIOR VENA CAVA

    Directory of Open Access Journals (Sweden)

    Parikhita Hazarika

    2017-08-01

    Full Text Available Right-sided aortic arch is a rare anatomical variant present in about 0.1% of the adult population.1,2 Half of the cases are associated with an aberrant left subclavian artery (0.05%-0.1%. Right-sided aortic arch with aberrant left subclavian artery is less common than left-sided aortic arch with aberrant right subclavian artery (0.5-2.0%.3,4 A rightsided aortic arch is an anatomic variant resulting from persistence of the right fourth aortic arch and involution of the left. It can be associated with an aberrant left subclavian artery arises from Kommerell’s diverticulum. It is usually asymptomatic and diagnosed incidentally during adult age. A 40-year-old male presented with cough and a hump in the back. The patient was evaluated for scoliosis and plain CT thorax was done.

  7. Open Repair of a 12-cm Posttraumatic Aneurysm of Right Subclavian Artery

    Directory of Open Access Journals (Sweden)

    Konstantinos Tigkiropoulos

    2017-11-01

    Full Text Available PurposeTo present a rare case of a patient with a 12-cm posttraumatic right subclavian artery aneurysm successfully treated with aneurysmectomy and innominate-axillary bypass.Case reportA 54-year-old man presented to the emergency department due to progressive dyspnea and hoarseness of voice. His medical record was unremarkable except that he had right-sided pneumothorax and multiple rib fractures from a car accident 16 years ago. A chest X-ray showed a mass in the upper lobe of the right lung, and the patient was hospitalized for further investigation. A computed tomography (CT with intravenous contrast of the thorax was performed, which depicted a giant aneurysm of the right subclavian artery. Vascular and cardiothoracic surgeons were consulted immediately, and the operation was scheduled. Aneurysmectomy and innominate-axillary bypass were performed. The patient had an uncomplicated progress and was discharged on 5 days followed by a single antiplatelet therapy and symptom-free.ConclusionPosttraumatic subclavian artery aneurysm is a rare entity. Imaging of the thorax is essential for the diagnosis and surgical preparation of the patient. Open repair remains the gold standard therapy for subclavian artery aneurysm despite the improvements in endovascular surgery in such huge aneurysms.

  8. A Novel Combined Hybrid Approach to Enable Revascularisation of a Trauma-Induced Subclavian Artery Injury

    Directory of Open Access Journals (Sweden)

    C.N. Sabbagh

    Full Text Available : Introduction: This case highlights the complexity of upper limb revascularization after a subclavian artery traumatic injury and strengthens the role of a hybrid/multi-disciplinary approach to such injuries. Report: A 45-year-old male patient presented with an acute right upper limb following a traumatic injury to the right subclavian artery due to a motor vehicle accident (MVA. Associated injuries included an unstable cervical spine injury, a large open right clavicular injury, and a brain injury, which limited the potential revascularisation options available. The arm was revascularised using a hybrid endovascular/open surgical approach, namely embolization of the proximal subclavian artery (just distal to vertebral artery and a right common femoral artery to distal axillary artery bypass using prosthetic material. Discussion: Blunt injuries to the subclavian artery are often high impact, complex and associated with multiple injuries to surrounding structures, which limit the role of standard procedures used in the elective setting. This case highlights the role of multidisciplinary team involvement, using a hybrid approach and a novel distal inflow site to restore upper limb perfusion. Keywords: Upper limb, Ischemia, Trauma, Revascularization

  9. Aneurysm of the aberrant right subclavian artery – a case report

    International Nuclear Information System (INIS)

    Godlewski, Janusz; Widawski, Tomasz; Michalak, Maciej; Kmieć, Zbigniew

    2010-01-01

    The right subclavian artery, originating not from the brachiocephalic trunk but directly from the aortic arch, is a rare anatomical abnormality. ‘Arteria lusoria’ is the accepted name of the retroesophageal right subclavian artery. Such a vessel location, between the vertebral column and the esophagus, determines its course to the right. This defect may be asymptomatic, found during autopsy or coincidentally during diagnostic procedures. However, it may also be symptomatic. The course of this major blood vessel in the limited anatomical space may cause symptoms of mediastinal organ compression. The aim of this paper was to present two cases of abnormal anatomical course of the right subclavian artery and its aneurismal dilation. In this study, CT scans of the saccular aneurysm of the retroesophageal right subclavian artery were used: of a male patient diagnosed at Euromedic Diagnostics in Olsztyn and of a female patient, from the resources of the Radiological Dept. at MSWiA Hospital in Olsztyn An 85-year-old female was admitted to Hospital ER for congestive heart failure decompensation. Her chest X-ray revealed a round mass in the upper right mediastinum. Chest CT confirmed the presence of a saccular aneurysm of the lusory artery, 6.5 cm in diameter, partially filled with thrombotic material. The patient died in hospital from myocardial infarction that was not related to the aneurysm. A 61-year-old male patient had a chest X-ray which showed a round opacity on the apex of the right lung. The diagnostic process comprised also chest computed tomography. The examination showed an anomalous origin of the right subclavian artery, with aneurysmal dilation and compression of the oesophagus and of the trachea. An intraluminal thrombus was found. The patient remained under observation till the next CT examination, 6 months later. The presented rare cases of arteria lusoria aneurysm are not only casuistic reports. They also show the value of modern MDCT diagnostics

  10. Aberrant right subclavian artery causing megaoesophagus in three cats.

    Science.gov (United States)

    Cinti, F; Della Santa, D; Borgonovo, S; Bussadori, R; Troiano, D; Pisani, G

    2018-05-07

    Three entire, domestic, shorthair male cats (age range: 3 months to 5 years) were referred because of regurgitation. Megaoesophagus attributable to aberrant right subclavian artery, originating from the aorta at the level of the fourth intercostal space, was diagnosed in all cats using thoracic radiography and CT angiography. One cat had concurrent patent ductus arteriosus with a normal aortic arch. Three-dimensional volume-rendered CT images were used to assess the malformations and to plan surgery for the treatment of the vascular anomalies. Different surgical approaches were used in the two kittens. The third cat was not operated. CT angiography is well suited for preoperative planning in cats with aberrant right subclavian artery alone or in combination with other vascular anomalies. © 2018 British Small Animal Veterinary Association.

  11. Subclavian artery dissection during catheterization in a patient after irradiation

    International Nuclear Information System (INIS)

    Kanazawa, Susumu; Hiraki, Yoshio; Fujie, Shunji; Sato, Nobuo.

    1997-01-01

    A 47-year-old woman with right breast cancer underwent partial mastectomy and had irradiations to the primary and metastatic sites, including the left supraclavicular region. During catheterization of the left internal mammary artery for arterial infusion therapy, the patient developed an iatrogenic dissection and subsequent occlusion of the left subclavian artery. Arterial infusion of tissue plasminogen activator into the artery resulted in recanalization and improvement of clinical signs and symptoms. (author)

  12. Absent right common carotid artery associated with aberrant right subclavian artery.

    Science.gov (United States)

    Uchino, Akira; Uwabe, Kazuhiko; Osawa, Iichiro

    2018-06-01

    Rarely, the external and internal carotid arteries arise separately from the brachiocephalic trunk and right subclavian artery (SA) or the aortic arch and reflect the absence of a common carotid artery (CCA). We report a 45-year-old man with absent right CCA associated with aberrant right SA, an extremely rare combination, diagnosed by computed tomography (CT) angiography during follow-up for postoperative aortic dissection. Retrospective careful observation of preoperative postcontrast CT revealed the absent right CCA. Previously reported arch variations associated with absent CCA include cervical aortic arch, double aortic arch, and right aortic arch.

  13. Traumatic partial avulsion of a single right subclavian artery from the aortic arch and definitive repair.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Sears-Rogan, Pamela; Young, Richard S; Kanda, Louis T; Ellis, Jennifer L

    2006-01-01

    Blunt injury to the right subclavian artery is a rare complication of severe deceleration trauma often associated with significant morbidity and mortality. We describe an atypical presentation in a patient who sustained a traumatic avulsion of his right subclavian artery arising off the aortic arch. An interposition graft was used to restore the continuity of the artery to the ascending thoracic aorta.

  14. Subclavian Aberrant right artery aneurysm causing a common carotid trunk: findings in CT and MR

    International Nuclear Information System (INIS)

    Quiroga Gomez, S.; Alvarez Castells, A.; Dominguez Oronoz, R.; Gifre Bassols, L.

    1995-01-01

    We present a case of aberrant right subclavian artery aneurysm causing dysphagia, dysphonia, and Claude-Bernard-Horner's syndrome by compression of adjacent structures, initially diagnosed with plain chest radiography and barium-swallow examination. CT and MRI confirmed this vascular anomaly and showed a common carotid trunk, associated to aberrant subclavian artery in 29% of cases. (Author) 10 refs

  15. Right-sided aortic arch with anomalous origin of the left subclavian artery: Case report

    Directory of Open Access Journals (Sweden)

    Vučurević Goran

    2011-01-01

    Full Text Available Introduction. A right-sided aortic arch is a rare congenital defect of the aorta with incidence of 0.05% to 0.1% reported in published series. Usually it is associated with congenital heart anomalies and esophageal and tracheal compression symptoms. We present a case of a right-sided aortic arch of anomalous left subclavian artery origin, accidentally revealed during multislice CT (MSCT supraaortic branches angiography. Case Outline. A 53-year-old female patient was examined at the Outpatients’ Unit of the Vascular Surgery University Clinic for vertigo, occasional dizziness and difficulty with swallowing. Physical examination revealed a murmur of the left supraclavicular space, with 15 mmHg lower rate of arterial tension on the left arm. Ultrasound of carotid arteries revealed 60% stenosis of the left subclavian artery and bilateral internal carotid artery elongation. MSCT angiography revealed a right-sided aortic arch with aberrant separation of the left subclavian artery that was narrowed 50%, while internal carotid arteries were marginally elongated. There was no need for surgical treatment or percutaneous interventions, so that conservative treatment was indicated. Conclusion. A right-sided aortic arch is a very rare anomaly of the location and branching of the aorta. Multislice CT angiography is of great importance in the diagnostics of this rare disease.

  16. Bilateral subclavian origin of the bronchial arteries combined with absence of other origins.

    Science.gov (United States)

    Jie, Bing; Sun, Xi-Wen; Yu, Dong; Jiang, Sen

    2014-08-01

    There are numerous anatomical variations of the sites of origin of the bronchial arteries (BAs). A subclavian origin of a BA involves an aberrant artery that originates from the subclavian artery (SCA) or its branches. However, the aberrant artery usually originates directly from the SCA, and an SCA-origin BA arising from the branches of the SCA is rare. We herein present an extremely rare case of a right BA arising from the ipsilateral costocervical trunk, and a left BA arising from the ipsilateral thyrocervical trunk, in the absence of other origins of the BA. This anatomical variation was detected during pretherapeutic evaluation by multidetector-row computed tomography and confirmed by selective angiography. Recognition of these anatomic variations is important to surgical, diagnostic, and interventional radiologic procedures in the thorax.

  17. Aberrant right subclavian artery- suggested mechanism for esophageal foreign body impaction: Case report

    Directory of Open Access Journals (Sweden)

    Best Lael A

    2011-04-01

    Full Text Available Abstract Aberrant right subclavian artery (ARSA is asymptomatic in most cases. This variant anatomy can cause dysphagia in elderly patients. Impaction of foreign body in the esophagus is rarely the presenting symptom of ARSA. We present an eighty four years old patient who first presented with esophageal foreign body impaction and was diagnosed with an aberrant right subclavian artery compressing the esophagus just below the site of impaction. We assume that the exact place of impaction was not incidental and that a relative narrowing of the esophagus caused by the vascular anomaly is responsible for this specific presentation.

  18. Subclavian artery stenosis caused by non-specific arteritis (Takayasu disease): treatment with Palmaz stent

    Energy Technology Data Exchange (ETDEWEB)

    Maskovic, J.; Jankovic, S.; Lusic, I.; Cambj-Sapunar, L.; Mimica, Z.; Bacic, A

    1999-09-01

    A 32-year old woman was admitted to the hospital with a sudden onset of right-sided hemiplegia and aphasia. Immediate angiographic examination revealed a severe form of type I Takayasu arteritis with occlusion of all supra-aortic vessels, with the exception of the left subclavian artery which was, however, almost completely occluded 1 cm proximal to the origin of the left vertebral artery. Since the latter provided the entire blood supply to the brain tissues, an immediate attempt was undertaken to dilate the left subclavian artery; when this was unrewarding, stenting of the lesion was successfully accomplished with excellent primary and 6-month follow-up results.

  19. Subclavian artery stenosis caused by non-specific arteritis (Takayasu disease): treatment with Palmaz stent

    International Nuclear Information System (INIS)

    Maskovic, J.; Jankovic, S.; Lusic, I.; Cambj-Sapunar, L.; Mimica, Z.; Bacic, A.

    1999-01-01

    A 32-year old woman was admitted to the hospital with a sudden onset of right-sided hemiplegia and aphasia. Immediate angiographic examination revealed a severe form of type I Takayasu arteritis with occlusion of all supra-aortic vessels, with the exception of the left subclavian artery which was, however, almost completely occluded 1 cm proximal to the origin of the left vertebral artery. Since the latter provided the entire blood supply to the brain tissues, an immediate attempt was undertaken to dilate the left subclavian artery; when this was unrewarding, stenting of the lesion was successfully accomplished with excellent primary and 6-month follow-up results

  20. Left subclavian artery revascularization as part of thoracic stent grafting

    NARCIS (Netherlands)

    Saouti, N.; Hindori, V.; Morshuis, W.J.; Heijmen, R.H.

    2015-01-01

    OBJECTIVES: Intentional covering of the left subclavian artery (LSA) as part of thoracic endovascular aortic repair (TEVAR) can cause (posterior) strokes or left arm malperfusion. LSA revascularization can be done as prophylaxis against, or as treatment of, these complications. We report our

  1. Carotid-subclavian bypass for subclavian steal syndrome following coarctation repair in infancy

    Directory of Open Access Journals (Sweden)

    Scott Chowning

    2012-01-01

    Full Text Available A 19 year old man presented with dizziness that was exacerbated while using left arm. On investigation, subclavian steal syndrome (SSS was diagnosed. He underwent left carotid to subclavian bypass with relief of symptoms. Subclavian steal syndrome, although rare, should be considered in the differential diagnosis in patients with the history of subclavian artery manipulation in the past in proper settings.

  2. Subclavian artery aneurysm in a patient with vascular Ehlers-Danlos syndrome.

    Science.gov (United States)

    Yasuda, Shota; Imoto, Kiyotaka; Uchida, Keiji; Uranaka, Yasuko; Kurosawa, Kenji; Masuda, Munetaka

    2016-02-01

    We describe our experience of surgical treatment in a 28-year-old woman with vascular Ehlers-Danlos syndrome. A right subclavian artery aneurysm was detected. The right vertebral artery arose from the aneurysm. Digital subtraction angiography showed interruption of the left vertebral artery. The aneurysm was excised and the right vertebral artery was anastomosed end-to-side to the right common carotid artery under deep hypothermia and circulatory arrest. The patient remained very well 4 years after surgery, with no late vascular complication. © The Author(s) 2014.

  3. Contemporary management of subclavian and axillary artery injuries-A Western Trauma Association multicenter review.

    Science.gov (United States)

    Waller, Christine J; Cogbill, Thomas H; Kallies, Kara J; Ramirez, Luis D; Cardenas, Justin M; Todd, S Rob; Chapman, Kayla J; Beckman, Marshall A; Sperry, Jason L; Anto, Vincent P; Eriksson, Evert A; Leon, Stuart M; Anand, Rahul J; Pearlstein, Maura; Capano-Wehrle, Lisa; Cothren Burlew, Clay; Fox, Charles J; Cullinane, Daniel C; Roberts, Jennifer C; Harrison, Paul B; Berg, Gina M; Haan, James M; Lightwine, Kelly

    2017-12-01

    Subclavian and axillary artery injuries are uncommon. In addition to many open vascular repairs, endovascular techniques are used for definitive repair or vascular control of these anatomically challenging injuries. The aim of this study was to determine the relative roles of endovascular and open techniques in the management of subclavian and axillary artery injuries comparing hospital outcomes, and long-term limb viability. A multicenter, retrospective review of patients with subclavian or axillary artery injuries from January 1, 2004, to December 31, 2014, was completed at 11 participating Western Trauma Association institutions. Statistical analysis included χ, t-tests, and Cochran-Armitage trend tests. A p value less than 0.05 was significant. Two hundred twenty-three patients were included; mean age was 36 years, 84% were men. An increase in computed tomography angiography and decrease in conventional angiography was observed over time (p = 0.018). There were 120 subclavian and 119 axillary artery injuries. Procedure type was associated with injury grade (p < 0.001). Open operations were performed in 135 (61%) patients, including 93% of greater than 50% circumference lacerations and 83% of vessel transections. Endovascular repairs were performed in 38 (17%) patients; most frequently for pseudoaneurysms. Fourteen (6%) patients underwent a hybrid procedure. Use of endovascular versus open procedures did not increase over the duration of the study (p = 0.248). In-hospital mortality rate was 10%. Graft or stent thrombosis occurred in 7% and graft or stent infection occurred in 3% of patients. Mean follow-up was 1.6 ± 2.4 years (n = 150). Limb salvage was achieved in 216 (97%) patients. The management of subclavian and axillary artery injuries still requires a wide variety of open exposures and procedures, especially for the control of active hemorrhage from more than 50% vessel lacerations and transections. Endovascular repairs were used most often for

  4. Surgical treatment of massive bleeding of a right aberrant subclavian artery after oesophageal stent removal

    Directory of Open Access Journals (Sweden)

    Michael Raum

    2018-06-01

    Full Text Available We report a case of a 9-year-old female who required surgical treatment and resuscitation after severe transoesophageal bleeding of a right aberrant subclavian artery (RASA. Bleeding of this RASA was caused by a mechanical irritation due to an oesophageal stent. The stent was placed weeks before to dilate the oesophagus after accidental ingestion of a caustic agent. Although conservative management of benign oesophageal stenosis in children is highly recommended, there are still some major complications to be considered. To avoid erosion of aberrant subclavian artery vascular rings and slings, as described in several case reports, these vessels should be excluded by computed tomography (CT or magnetic resonance imaging (MRI scans before placement of oesophageal stents. This case suggests that management of caustic ingestion in children is still a major challenge in paediatric surgical departments. Keywords: Paediatric surgery, Chemical Burn, Oesophageal stenosis, Oesophageal stenting, Vascular abnormalities, Right aberrant subclavian artery

  5. Treatment of an Unusual Occurrence of a Complex Left Subclavian Artery/Left Internal Mammary Artery Bifurcation Stenosis in the Setting of Coronary Subclavian Steal Syndrome and Ischemic Left Ventricular Systolic Dysfunction

    Directory of Open Access Journals (Sweden)

    Michael J. Martinelli

    2018-01-01

    Full Text Available This case will illustrate the clinical and unique technical challenges, not previously reported, in a patient with a history of progressive left ventricular (LV systolic dysfunction, congestive heart failure (CHF, myocardial infarction (MI, and a complex bifurcation lesion of the left subclavian artery (SA involving the left internal mammary artery (LIMA in the setting of coronary subclavian steal syndrome (CSSS. The approach to this lesion is complicated by significant LIMA involvement requiring intervention directed toward both the SA and the LIMA in the presence of severe LV systolic dysfunction. This clinical scenario necessitates a careful technique, utilizing bifurcation methods similar to those used in coronary intervention.

  6. Giant aneurysm of the right intra thoracic sub-clavian artery ...

    African Journals Online (AJOL)

    Aneurysms of the intra-thoracic subclavian artery (SCA) are rare. They are often revealed by complications. Surgical treatment is always indicated. Endovascular treatment is a less invasive alternative. We report a case of a 60 years-old woman admitted for right chest pain and dysphonia. Laryngoscopy noted a right vocal ...

  7. Association of left subclavian artery coverage without revascularization and spinal cord ischemia in patients undergoing thoracic endovascular aortic repair: A Vascular Quality Initiative® analysis.

    Science.gov (United States)

    Teixeira, Pedro Gr; Woo, Karen; Beck, Adam W; Scali, Salvatore T; Weaver, Fred A

    2017-12-01

    Objectives Investigate the impact of left subclavian artery coverage without revascularization on spinal cord ischemia development in patients undergoing thoracic endovascular aortic repair. Methods The Vascular Quality Initiative thoracic endovascular aortic repair module (April 2011-July 2014) was analyzed. Patients undergoing left subclavian artery coverage were divided into two groups according to revascularization status. The association between left subclavian artery revascularization with the primary outcome of spinal cord ischemia and the secondary outcome of stroke was assessed with multivariable analysis adjusting for between-group baseline differences. Results The left subclavian artery was covered in 508 (24.6%) of the 2063 thoracic endovascular aortic repairs performed. Among patients with left subclavian artery coverage, 58.9% underwent revascularization. Spinal cord ischemia incidence was 12.1% in the group without revascularization compared to 8.5% in the group undergoing left subclavian artery revascularization (odds ratio (95%CI): 1.48(0.82-2.68), P = 0.189). Multivariable analysis adjustment identified an independent association between left subclavian artery coverage without revascularization and the incidence of spinal cord ischemia (adjusted odds ratio (95%CI): 2.29(1.03-5.14), P = 0.043). Although the incidence of stroke was also higher for the group with a covered and nonrevascularized left subclavian artery (12.1% versus 8.5%), this difference was not statistically significant after multivariable analysis (adjusted odds ratio (95%CI): 1.55(0.74-3.26), P = 0.244). Conclusion For patients undergoing left subclavian artery coverage during thoracic endovascular aortic repair, the addition of a revascularization procedure was associated with a significantly lower incidence of spinal cord ischemia.

  8. Changing Profiles of Diagnostic and Treatment Options in Subclavian Artery Aneurysms

    NARCIS (Netherlands)

    Vierhout, B. P.; Zeebregts, C. J.; van den Dungen, J. J. A. M.; Reijnen, M. M. P. J.

    Background: Subclavian artery aneurysms (SAAs) are rare and may cause life- and limb-threatening complications. Therapeutic options greatly differ as do access alternatives. The aim of the study was to assess its clinical presentation, diagnostics and therapeutic options as reported in the

  9. Isolation of the right subclavian artery in a patient with d-transposition of the great arteries.

    Science.gov (United States)

    Arunamata, Alisa; Perry, Stanton B; Kipps, Alaina K; Vasanawala, Shreyas S; Axelrod, David M

    2015-01-01

    Isolation of the right subclavian artery (RSCA) is rare, and this finding in association with d-transposition of the great arteries (d-TGA) is extremely unusual. We present a case of an isolated RSCA in a newborn with d-TGA in whom the clinical presentation was diagnostic. We discuss the imaging modalities used to confirm the diagnosis, the embryological basis of the finding, and the surgical repair.

  10. A composed graft for subclavian artery reconstruction in case of redo surgery for aortic coarctation

    Directory of Open Access Journals (Sweden)

    Fabrizio Sansone

    2013-01-01

    Full Text Available We report the case of a 66-year-old woman admitted to the intensive care unit (ICU for ongoing dyspnea and hemoptoe. She was operated upon in 1979 for aortic coarctation by the interposition of a 14 mm Dacron prosthesis from the left subclavian artery to descending aorta. Clinical evaluation performed over the years was normal with no signs of cardiac failure or prosthesis malfunctioning. The computed tomography scans (CT showed a progressive increase of the descending aorta diameters and the onset of a pseudo-aneurysm of 50 mm in diameter. Patient was re-operated through a median sternotomy enlarged by a left thoracotomy and intra-operative findings revealed the pseudo-aneurysm originating from a dehiscence of the proximal suture. In order to allow a safe reconstruction of the dilated subclavian artery, a T-shaped composed graft was confectioned and then sutured to the descending aorta and the subclavian artery, respectively. Post-operative course was uneventful and three months CT scan showed a normal position of the composed graft.

  11. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  12. Iatrogenic Subtotal Stenosis of the Right Subclavian Artery Treated With Percutaneous Transluminal Angioplasty

    International Nuclear Information System (INIS)

    Smeenk, Robert M.; Kock, Mark C. J. M.; Elgersma, Otto E. H.; Schnater, Marco J.

    2011-01-01

    This report describes a rare vascular complication of surgical placement of a marking clip and a possible approach to problem solving. A 55-year-old patient presented with loss of sensation in the fingers and loss of peripheral pulsations in the right arm 4 days after right upper lobectomy for a pT2N1 moderately differentiated adenocarcinoma of the lung. Duplex examination and computed tomography were performed the same day and showed a subtotal stenosis of the right subclavian artery, which was caused by the surgical placement of a metal clip to mark the surgical boundary. Selective angiography was subsequently performed. Percutaneous transluminal angioplasty (PTA) successfully dilated the stenosis and pushed the clip off. Flow in the right subclavian artery (RSA) was completely restored as were neurology and peripheral pulses. In conclusion, arterial stenosis by a surgical (marking) clip may be feasibly treated with PTA.

  13. "Classical Blalock-Taussig shunt" gone wrong: Confusing the right common carotid with right subclavian artery.

    Science.gov (United States)

    Idhrees, A Mohammed; Cherian, Vijay Thomas; Menon, Sabarinath; Mathew, Thomas; Dharan, Baiju S; Jayakumar, Karunakaran

    2015-01-01

    A 14-year-old girl underwent classical Blalock-Taussig shunt at 5 months of age. Computed tomography evaluation showed "Adachi type H" pattern of aortic arch vessels with the right common carotid artery being anastomosed to the right pulmonary artery mistaking it for the right subclavian artery.

  14. Coil embolization of internal mammary artery injured during central vein catheter and cardiac pacemaker lead insertion

    Energy Technology Data Exchange (ETDEWEB)

    Chemelli, A.P. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria)], E-mail: Andreas.Chemelli@i-med.ac.at; Chemelli-Steingruber, I.E. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria); Bonaros, N. [Department of Cardiovascular Surgery, Innsbruck Medical University (Austria); Luckner, G. [Department of Anaesthesiology and Critical Care Medicine, Innsbruck Medical University (Austria); Millonig, G. [Department of Gastroenterology and Hepatology, Innsbruck Medical University (Austria); Seppi, K. [Department of Neurology, Innsbruck Medical University (Austria); Lottersberger, C.; Jaschke, W. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria)

    2009-08-15

    Purpose: This study describes several cases of endovascular coil embolization of the proximal internal mammary artery injured by blind approach to the subclavian vein for central venous catheter or pacemaker lead insertion. Materials and methods: We conducted a retrospective analysis of five patients with iatrogenic arterial lesions of the internal mammary artery (IMA). The lesions occurred in three patients from a puncture of the subclavian vein during insertion of a central venous catheter and in two patients from a puncture of the subclavian vein for insertion of a pacemaker lead. Four patients had acute symptoms of bleeding with mediastinal hematoma and hematothorax and one patient was investigated in a chronic stage. A pseudoaneurysm was detected in all five patients. All four acute and hemodynamic unstable patients required hemodynamic support. Results: In all patients, embolization was performed using a coaxial catheter technique, and a long segment of the IMA adjacent distally and proximally to the source of bleeding was occluded with pushable microcoils. In one patient, additional mechanically detachable microcoils were used at the very proximal part of the IMA. Microcoil embolization of the IMA was successful in all patients, and the source of bleeding was eliminated in all patients. Conclusion: Transarterial coil embolization is a feasible and efficient method in treating acute bleeding and pseudoaneurysm of the IMA and should be considered if mediastinal hematoma or hemathorax occurs after blind puncture of the subclavian vein.

  15. Isolation of the right subclavian artery in a patient with d-transposition of the great arteries

    Directory of Open Access Journals (Sweden)

    Alisa Arunamata

    2015-01-01

    Full Text Available Isolation of the right subclavian artery (RSCA is rare, and this finding in association with d-transposition of the great arteries (d-TGA is extremely unusual. We present a case of an isolated RSCA in a newborn with d-TGA in whom the clinical presentation was diagnostic. We discuss the imaging modalities used to confirm the diagnosis, the embryological basis of the finding, and the surgical repair.

  16. Subclavian Artery Pseudoaneurysm Formation 3 Months after a Game of Rugby Union

    Directory of Open Access Journals (Sweden)

    T. Evans

    2015-01-01

    Full Text Available Pseudoaneurysms of the subclavian artery remain a rare complication after fracture of the clavicle. We report a case of delayed diagnosis of a subclavian artery pseudoaneurysm after a closed fracture of the clavicle in a 15-year-old patient, 3 months after the original injury while playing rugby union. Despite several attendances to the Emergency Department with vague symptoms, the final diagnosis was confirmed by duplex ultrasound and Computed Tomography of the thorax. Surgical repair was indicated due to acute limb ischaemia from distal embolisation from a large pseudoaneurysm, with the patient making a full recovery. This case highlights the need for clinical vigilance when assessing patients, particularly on repeated occasions when their recovery appears to be impaired. A thorough history and clinical examination can raise suspicion of even rare occurrences and aid prompt management.

  17. Unintentional arterial puncture during cephalic vein cannulation: case report and anatomical study

    NARCIS (Netherlands)

    Lirk, P.; Keller, C.; Colvin, J.; Colvin, H.; Rieder, J.; Maurer, H.; Moriggl, B.

    2004-01-01

    The cephalic antebrachial vein is often used for venous access. However, superficial radial arteries of the forearm are known and unintentional arterial puncture can result from attempts to cannulate the lateral veins of the arm. Accidental puncture of a superficial radial artery during peripheral

  18. Repair of Multiple Subclavian and Axillary Artery Aneurysms in a 58-Year-Old Man with Marfan Syndrome

    OpenAIRE

    Dolapoglu, Ahmet; de la Cruz, Kim I.; Preventza, Ourania; Coselli, Joseph S.

    2016-01-01

    Dilation of the ascending aorta and aortic dissections are often seen in Marfan syndrome; however, true aneurysms of the subclavian and axillary arteries rarely seem to develop in patients who have this disease. We present the case of a 58-year-old man with Marfan syndrome who had undergone a Bentall procedure and thoracoabdominal aortic repair for an aortic dissection and who later developed multiple aneurysmal dilations of his right subclavian and axillary arteries. The aneurysms were succe...

  19. "Classical Blalock-Taussig shunt" gone wrong: Confusing the right common carotid with right subclavian artery

    Directory of Open Access Journals (Sweden)

    A Mohammed Idhrees

    2015-01-01

    Full Text Available A 14-year-old girl underwent classical Blalock-Taussig shunt at 5 months of age. Computed tomography evaluation showed "Adachi type H" pattern of aortic arch vessels with the right common carotid artery being anastomosed to the right pulmonary artery mistaking it for the right subclavian artery.

  20. Aberrant right vertebral artery originating from the aortic arch distal to the left subclavian artery: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Soo Heui; Baek, Hye Jin [Dept. of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2014-03-15

    We present a rare case of an aberrant right vertebral artery originated from the distal aortic arch. This issue has been incidentally detected on a preoperative CT angiography after a stabbing injury of the cervical spinal cord. Normally, the right vertebral artery originates from the right subclavian artery. Therefore, in this case report we will review the incidence and the embryological mechanism of this aberrant course of the right vertebral artery and we will discuss as well the clinical importance of this variation.

  1. Development and psychometric evaluation of the arterial puncture self-efficacy scale.

    Science.gov (United States)

    Hernández-Padilla, José Manuel; Granero-Molina, José; Márquez-Hernández, Verónica V; Suthers, Fiona; Fernández-Sola, Cayetano

    2016-05-01

    Arterial puncture for arterial blood gases (ABG) analysis can be a risky, painful, difficult-to-perform procedure that is often insufficiently practised and generates stress and discomfort amongst patients and healthcare professionals. Self-efficacy is a key component in the acquisition of procedural skills. Therefore, professionals' self-efficacy in arterial puncture should be measured before attempting the procedure on real patients. To develop and psychometrically assess a self-efficacy scale in arterial puncture. An observational cross-sectional design was used in this study. Faculty of Education Sciences, Nursing and Physiotherapy in a higher education institution in the south of Spain. A convenience sample of 342 nursing students entered and completed the study. All participants met the following inclusion criteria: (1) ≥18years old and (2) enrolled in a nursing degree programme during the 2014/2015 academic year. Participants were 74% female (n=254) and their age ranged from 18 to 50, with a mean age of 21.74years (SD=5.14). The Arterial Puncture Self-Efficacy Scale (APSES) was developed and psychometrically tested. Reliability and content validity were studied. Predictive validity and concurrent validity assessed criterion validity. In addition, principal component analysis and known-group analysis evaluated construct validity. Principal component analysis revealed the two-subscale structure of the final 22-item version of the Arterial Puncture Self-Efficacy Scale (APSES). A total Cronbach's alpha coefficient of 0.97 showed its high reliability. The APSES' content validity index was excellent (S-CVI/Ave=0.95). Predictive and concurrent validity analysis demonstrated the good criterion validity of the tool. Supporting the APSES' sensitivity and specificity, known-groups analysis evidenced significant differences (pgood psychometric properties for measuring self-efficacy in arterial puncture for ABG analysis. Copyright © 2016 Elsevier Ltd. All rights

  2. [Right-side aortic arch with aberrant left subclavian artery and Kommerell's diverticulum. A cause of vascular ring].

    Science.gov (United States)

    Tamayo-Espinosa, Tania; Erdmenger-Orellana, Julio; Becerra-Becerra, Rosario; Balderrabano-Saucedo, Norma; Segura-Standford, Begoña

    The right-side aortic arch may be associated with aberrant left subclavian artery, in some cases this artery originates from an aneurismal dilation of the aorta called Kommerell's diverticulum. A report is presented on 2 cases of vascular ring formed by a right-side aortic arch, anomalous left subclavian artery, Kommerell's diverticulum and left patent ductus arteriosus. A review the literature was also performed as regards the embryological development and the imaging methods used to help in the diagnosis of this rare vascular anomaly. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  3. Use of a Collagen-Based Device for Closure of Low Brachial Artery Punctures

    International Nuclear Information System (INIS)

    Belenky, A.; Aranovich, D.; Greif, F.; Bachar, G.; Bartal, G.; Atar, E.

    2007-01-01

    Purpose. To report our experience with the Angioseal vascular closure device for hemostasis of distal brachial artery puncture. Methods. Between September 2003 and August 2005, 64 Angioseal vascular closure devices were inserted in 64 patients (40 men, 24 women; mean age 65 years) immediately after diagnostic or therapeutic arterial angiographies performed through a 5 Fr to 7 Fr sheath via the distal brachial artery. Ultrasound examination of the brachial artery preceded the angiography in all cases and only arteries wider than 4 mm were closed by the Angioseal. In cases of a sonographically evident thin subcutaneous space of the cubital fossa, tissue tumescence, using 1% Lidocaine, was performed prior to the arterial closure. Results. The deployment success rate was 100%. No major complications were encountered; only 2 patients developed puncture site hematoma, and these were followed conservatively. Conclusions. Closure of low brachial artery punctures with the Angioseal is simple and safe. No additional manual compression is required. We recommend its use after brachial artery access interventions, through appropriately wide arteries, to improve early patient ambulation and potentially reduce possible puncture site complications

  4. A Right-sided Aortic Arch with Kommerell's Diverticulum of the Aberrant Left Subclavian Artery Presenting with Syncope

    Directory of Open Access Journals (Sweden)

    Ming-Hsun Yang

    2009-05-01

    Full Text Available A right-sided aortic arch with an aneurysm of the aberrant subclavian artery is a rare disease. We report a case of Kommerell's diverticulum of an aberrant left subclavian artery in a patient with a right-sided aortic arch. Fewer than 50 cases have been reported in the literature. A number of operative strategies are described. Right thoracotomy provides good exposure and avoids the morbidity associated with bilateral thoracotomy or sternotomy and thoracotomy. In our patient with symptoms of dysphagia, syncope, and left subclavian steal syndrome, a left thoracotomy was used. The repair was accomplished by division of a left ligamentum arteriosum, obliteration of the Kommerell's aneurysm, and an aorto-subclavian bypass. Postoperative complications included left vocal cord palsy and Horner's syndrome. Hoarseness and left ptosis recovered spontaneously 3 months after surgery, and the patient remained symptom-free at the 1-year follow-up. We believe a left thoracotomy for direct repair of Kommerell's diverticulum is a simple and safe method without the increased morbidity found in other procedures.

  5. Repair of Multiple Subclavian and Axillary Artery Aneurysms in a 58-Year-Old Man with Marfan Syndrome.

    Science.gov (United States)

    Dolapoglu, Ahmet; de la Cruz, Kim I; Preventza, Ourania; Coselli, Joseph S

    2016-10-01

    Dilation of the ascending aorta and aortic dissections are often seen in Marfan syndrome; however, true aneurysms of the subclavian and axillary arteries rarely seem to develop in patients who have this disease. We present the case of a 58-year-old man with Marfan syndrome who had undergone a Bentall procedure and thoracoabdominal aortic repair for an aortic dissection and who later developed multiple aneurysmal dilations of his right subclavian and axillary arteries. The aneurysms were successfully repaired by means of a surgical bypass technique in which a Dacron graft was placed between the carotid and brachial arteries. We also discuss our strategy for determining the optimal surgical approach in these patients.

  6. Prenatal diagnosis of aberrant right subclavian artery in an unselected population

    Energy Technology Data Exchange (ETDEWEB)

    Song, Mi Jin; Han, Byoung Hee; Kim, Young Hwa; Yoon, So Young; Lee, Yoo Mi; Jeon, Hye Su; Park, Bo Kyung [Cheil General Hospital and Women' s Healthcare Center, Dankook University College of Medicine, Seoul (Korea, Republic of)

    2017-07-15

    The purpose of this study was to determine the frequency of aberrant right subclavian artery (ARSA) among unselected fetuses and to evaluate its association with chromosomal abnormalities and other congenital anomalies.In all, 7,547 fetuses (gestational age, 20 to 34 weeks) were examined using routine antenatal sonography at our institution between April 2014 and September 2015. The right subclavian artery was assessed using grayscale and color Doppler ultrasonography in the transverse 3-vessel and tracheal view, and confirmed in the coronal plane. ARSA was found in 28 fetuses (0.4%). Further, 27 of these 28 fetuses were euploid (96.4%). Trisomy 18 was the only chromosomal anomaly (3.6%) found in the study sample. ARSA was an isolated finding in 23 of the 28 cases (82.1%). In the remaining three cases (10.7%), ARSA was accompanied with extracardiac anomalies. Other cardiac defects were present in three cases (10.7%). Isolated ARSA does not seem to be associated with a significantly increased risk of aneuploidy. However, the possibility of fetal karyotyping, which is a more invasive procedure, should be discussed in the light of the overall risk of the fetus.

  7. A Rare Case of Esophageal Dysphagia in Children: Aberrant Right Subclavian Artery

    Directory of Open Access Journals (Sweden)

    Claudia Barone

    2016-01-01

    Full Text Available Dysphagia is an impairment of swallowing that may involve any structures from the mouth to the stomach. Esophageal dysphagia presents with the sensation of food sticking, pain with swallowing, substernal pressure, or chronic heartburn. There are many causes of esophageal dysphagia, such as motility disorders and mechanical and inflammatory diseases. Infrequently dysphagia arises from extrinsic compression of the esophagus from any vascular anomaly of the aortic arch. The most common embryologic abnormality of the aortic arch is aberrant right subclavian artery, clinically known as arteria lusoria. This abnormality is usually silent. Here, we report a case of six-year-old child presenting to us with a history of progressive dysphagia without respiratory symptoms. A barium esophagogram showed an increase of the physiological esophageal narrowing at the level of aortic arch, while at esophagogastroduodenoscopy there was an extrinsic pulsatile compression of the posterior portion of the esophagus suggesting an extrinsic compression by an aberrant vessel. Angio-CT (computed tomography scan confirmed the presence of an aberrant right subclavian artery.

  8. Anatomic landmarks of fluoroscopy guided puncture of the pulseless femoral artery

    International Nuclear Information System (INIS)

    Jeon, Min Hee; Han, Gi Seok; Kim, Sung Jin; Park, Kil Sun; Cha, Sang Hoon; Bae, Il Hun; Lee, Seung Young

    2006-01-01

    We wanted to improve puncturing the pulseless femoral artery by evaluating the anatomic landmarks that suggest the course of the femoral artery on fluoroscopy. We analyzed 37 hemipelvis spot images that were centered on the arterial sheath after puncture of the femoral artery. The inguinal angles were measured between the inguinal line connecting the anterior superior iliac spine and the symphysis pubis, and the line of the arterial sheath. Inguinal ligament ratios were measured as the distance from the symphysis pubis to the arterial sheath to the length of the inguinal ligament on the inguinal line. The femoral head ratios were measured as the distance from the medial margin of the femur head to the arterial sheath to the transverse length of the femur head. The mean inguinal angle was 66.5 and the mean inguinal ligament ratio was 0.42 (± 0.03). The mean femoral head ratio was 0.08 (± 0.18). In comparing the men and women, there was no significant difference in the inguinal angle and the femoral head ratio, but the inguinal distance ratio was larger in women (men: 0.41 ± 0.033, women: 0.44 ± 0.031, ρ < 0.05). The femoral artery generally courses just lateral to the medial margin of the femur head (femoral head ratio: 0.08) and the medial 40% of the inguinal ligament (inguinal ligament ratio: 0.42). So, consideration of these relations may be helpful for puncturing the pulseless femoral artery

  9. The closure device for the puncture point of femoral artery: an experiment in vitro

    International Nuclear Information System (INIS)

    Sun Jiantao; Zhang Junfeng; Wu Ke; Wang Yi

    2010-01-01

    Objective: To assess the blocking effects of a new-type closure device for the puncture point of femoral artery in vitro. Methods: An embolic colloidal substance with stable swelling value was embedded in an extracorporeal model which was used as an imitator of femoral artery blood flow velocity. Results: The embolization colloid was not displaced by the imitated blood flow lash, the embolic colloid was firmly attached to the puncture point and no fluid extravasation occurred. Conclusion: This new-type closure device for the puncture point of femoral artery is simple in structure and easy to manipulate with satisfactory blocking results. (authors)

  10. Aberrant right subclavian artery aneurysm confirmed by computerized tomography. Aneurisma de arteria subclavia derecha aberrante

    Energy Technology Data Exchange (ETDEWEB)

    Arteche, M.D.; Tejera, E.; Vega-Hazas, G.

    1991-01-01

    We present a case of aberrant right subclavian artery aneurysm in an asymptomatic woman. This disorder was found by chance in a thorax radiography due to an upper right mediastinal mass. CT confirmed the vascular anomaly as well as the aneurysm occurrence. (Author)

  11. Vertebral and carotid artery anomalies in patients with aberrant right subclavian arteries

    International Nuclear Information System (INIS)

    Tsai, I.C.; Lee, Tain; Tzeng, Wen-Sheng; Jan, Sheng-Lin; Fu, Yun-Ching; Chen, Min-Chi; Lin, Pao-Chun; Liao, Wan-Chun; Chen, C.C.C.

    2007-01-01

    There is little published evidence regarding the patterns and prevalence of vertebral artery (VA) and common carotid artery (CCA) anomalies in patients with an aberrant right subclavian artery (ARSCA). To study the patterns and prevalence of VA and CCA anomalies in patients with ARSCA. In a 2-year period we reviewed the children referred with suspected vascular ring who had undergone multidetector-row CT. Patients with ARSCA were reviewed for VA and CCA patterns and their prevalence and relevance were calculated. In total, 102 patients with ARSCA were identified. VA anomalies were present in 16 patients (15.7%), and CCA anomalies (common carotid trunk) in 21 patients (20.6%). In some patients with VA anomalies, the right VA arose from the right CCA and in some the left VA arose from the aortic arch. When the left VA arose from the aortic arch it was situated between the left CCA and the left SCA or between the left SCA and the ARSCA. If neurointerventionalists understand these potential anomalies and their prevalence, time and contrast medium could be saved when catheterizing the VA and CCA in patients with ARSCA. (orig.)

  12. Poland syndrome associated with an aberrant subclavian artery and vascular abnormalities of the retina in a child exposed to misoprostol during pregnancy.

    Science.gov (United States)

    Rosa, Rafael Fabiano Machado; Travi, Giovanni M; Valiatti, Fabiana; Zen, Paulo Ricardo Gazzola; Pinto, Louise Lapagesse; Kiss, Andrea; Graziadio, Carla; Paskulin, Giorgio Adriano

    2007-06-01

    Poland syndrome has been attributed to a process of vascular disruption, and exposure to misoprostol at 6-8 weeks of gestation has been shown to produce defects attributed to vascular disruption. Herein we report the first case of a patient with Poland syndrome associated with an aberrant subclavian artery and vascular abnormalities of the retina, whose mother used misoprostol during pregnancy. A White boy of 1 year and 7 months of age, whose mother used misoprostol during the second month of pregnancy, presented with bilateral epicanthal folds, aplasia of the sternocostal head of the pectoralis major muscle with a hypoplastic nipple on the right side, and asymmetry between the upper limbs. The results of an angiotomographic study showed the presence of an aberrant right subclavian artery. Ultrasonographic evaluation showed turbulence and a high peak in the diastolic velocity in both carotid arteries, suggesting stenosis. Ophthalmologic assessment disclosed an intense bilateral tortuosity of the retinal blood vessels, with arterialnarrowing and rarefaction of the retinal pigment epithelium. This case suggests that the mechanism of vascular disruption of misoprostol could be related to the aberrant subclavian artery and the observed Poland syndrome. His retinal findings are different from those in cases described thus far in the literature, and this pattern of anomaly has never been associated with a gestational exposure to misoprostol. The possibility of a relationship of the aberrant right subclavian artery and the pattern of blood flow verified in the carotid arteries with the eye fundus abnormalities could be causally related or simply coincidental.

  13. Results of subclavian to carotid artery bypass for occlusive disease of the common carotid artery: A retrospective cohort study.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Calio, Francesco G; Masci, Federica; Pasqua, Rocco; Frezzotti, Francesca; Peschillo, Simone

    2018-05-01

    Optimal treatment of significant atherosclerosis of the common carotid artery (CCA) is not well-defined. The purpose of this study was to evaluate the long-term results of prosthetic subclavian to carotid bypass for occlusive disease of the CCA. From January 1994 to December 2015, 45 patients, mean age 67 years, underwent an ipsilateral subclavian to carotid bypass for occlusive disease of the CCA. Thirty-eight patients (84%) presented with neurologic symptoms, including transitory ischemic attacks in 29 cases and minor strokes in 9 cases. The graft material consisted of a 7 mm polytetrafluoroethylene conduit, and the distal anastomosis was done on the carotid bulb in 21 patients, on the internal carotid artery in 19 cases, and on the distal CCA in 5 cases. Median length of follow-up was 58 months. Study endpoints were the combined postoperative stroke/mortality rate, graft infection, overall late survival, freedom from ipsilateral stroke, and graft patency. Postoperative stroke/mortality rate was 2%. No graft infection was observed throughout follow-up. At 60 months, overall survival, freedom from stroke, and graft patency were 71% (standard error [SE] = 0.07), 98% (SE = 0.02), and 95.5% (SE = 0.06), respectively. Subclavian to carotid bypass allows very good patency rates and excellent protection from postoperative and late stroke, remaining a benchmark for any other treatment method. Copyright © 2018. Published by Elsevier Ltd.

  14. Utility of the puncture of the radial artery in interventionist radiology

    International Nuclear Information System (INIS)

    Triana Rodriguez, Carlos Eduardo; Montes S, Mauricio; Barragan F, Jaime; Ucros Diaz Pablo; Ucros Diaz, Ignacio; Castillo, Luis Fernando

    1998-01-01

    We present the radial artery access, previous evaluation of collateral circulation with Allen's Test, as an alternative vascular access in patients with contraindications for femoral or axillary approaches. The radial artery puncture offers advantages, such as diminished bleeding and hematoma formation

  15. Severe upper extremity polyneuropathy due to inferior brachial plexus compression as a result of left subclavian artery pseudoaneurism

    Directory of Open Access Journals (Sweden)

    George Kosmadakis

    2012-01-01

    Full Text Available In the present report, we describe the case of a 76-year-old hemodialysis patient who was admitted with clinical features of neurological thoracic exit syndrome due to subclavian artery pseudoaneurism following the insertion of a dual lumen vascular internal jugular catheter (vascath with excellent outcome after endo-arterial stent placement.

  16. Two-phase summation imaging using transvenous DSA in subclavian steal syndrome

    International Nuclear Information System (INIS)

    Arlart, I.P.

    1984-01-01

    A simple method is reported to obtain a two-phase summation image in subclavian steal syndrome using digital subtraction angiography (DSA) via selection of a mask during the early arterial phase and the contrast image during delayed retrograde filling of the ipsilateral vertebral artery and the postocclusive subclavian artery. The summation image results by employing replay of the stored image information. (orig.) [de

  17. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...

  18. Effectiveness of sublingual nitroglycerin before puncture compared with conventional intra-arterial nitroglycerin in transradial procedures: a randomized trial

    Energy Technology Data Exchange (ETDEWEB)

    Turan, Burak, E-mail: drburakturan@gmail.com; Daşlı, Tolga; Erkol, Ayhan; Erden, İsmail

    2015-10-15

    Aim: Sublingual (SL) nitroglycerin administered before radial artery puncture can improve cannulation success and decrease the incidence of radial artery spasm (RAS) compared with intra-arterial (IA) nitroglycerin in transradial procedures. Methods: Patients undergoing diagnostic transradial angiography were randomized to IA (200 mcg) or SL (400 mcg) nitroglycerin. Primary endpoints were puncture time and puncture attempts. Secondary endpoint was the incidence of RAS. Results: Total of 101 participants (mean age 60 ± 11 years, 53% male) were randomized (51 in IA and 50 in SL groups). Puncture time (50 [36–75] vs 50 [35–90] sec), puncture attempts (1.18 ± 0.48 vs 1.20 ± 0.49), multiple punctures (13.7 vs 16.0%) and RAS (19.6 vs 24.0%) were not statistically different between IA vs SL groups respectively. A composite endpoint of all adverse events related to transradial angiography (multiple punctures, RAS, access site crossover, hypotension/bradycardia associated with nitroglycerin and radial artery occlusion) was very similar in IA vs SL groups (39 vs 40%, respectively). However puncture time was significantly longer with SL nitroglycerin in patients < 1.65 m height (47 [36–66] vs 63 [41–110] sec, p = 0.042). Multiple punctures seemed higher with SL nitroglycerin in patients with diabetes (0 vs 30%, p = 0.028) or in patients < 1.65 m height (7.4 vs 25%, p = 0.085). Likewise, RAS with SL nitroglycerin seemed more frequent in smokers compared to IA nitroglycerin (0 vs 27%, p = 0.089). Conclusions: SL nitroglycerin was not different from IA nitroglycerin in terms of efficiency and safety in overall study population. However it may be inferior to IA nitroglycerin in certain subgroups (shorter individuals, diabetics and smokers). - Highlights: • Improvement in radial artery puncture time and success with subcutaneous nitrate was reported. • Giving nitrate sublingually may have vasodilation along entire length of radial artery and may prevent RAS

  19. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    Science.gov (United States)

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  20. Initial and Long-Term Results of Endovascular Therapy for Chronic Total Occlusion of the Subclavian Artery

    International Nuclear Information System (INIS)

    Babic, Srdjan; Sagic, Dragan; Radak, Djordje; Antonic, Zelimir; Otasevic, Petar; Kovacevic, Vladimir; Tanaskovic, Slobodan; Ruzicic, Dusan; Aleksic, Nikola; Vucurevic, Goran

    2012-01-01

    Purpose: To study the initial and long-term results of angioplasty and primary stenting for the treatment of chronic total occlusion (CTO) of the subclavian artery (SA). Materials and Methods: From January 1999 to February 2010, 56 patients (25 men with a mean age of 58 ± 8 years) underwent endovascular treatment for CTO of the SA. Duplex scans and arteriograms confirmed occlusion in all cases. Indications for recanalization were subclavian steal syndrome in 33 patients (58.1%), arm claudication in 13 patients (23.2%), and coronary ischemia in 7 patients (12.5%) who had a history of previous coronary artery bypass grafting that included left internal thoracic artery graft. Three patients (5.4%) were treated before the scheduled coronary artery bypass surgery, which included left internal thoracic artery graft. After successful recanalization, all arteries were stented, and all of the patients were followed-up at 1, 3, 6, and 12 months after surgery and annually thereafter. Results: Successful recanalization of the SA was achieved in 46 patients (82.1%), and the complication rate was 7.1%. During follow-up (mean 40 ± 26 months; range 2 to 125), the primary patency rates after 1 and 3 years were 97.9% and 82.7%, respectively. At the end of follow-up, 76% of the arteries showed no evidence of restenosis. Univariate analysis failed to identify any variable predictive of long-term patency of successfully recanalized SA. Conclusion: Percutaneous transluminal angioplasty with stenting of the complete total occlusion of the SA is a safe and effective procedure associated with low risks and good long-term results.

  1. Computed tomography angiography reveals stenosis and aneurysmal dilation of an aberrant right subclavian artery causing systemic blood pressure misreading in an old Pekinese dog.

    Science.gov (United States)

    Kim, Jaehwan; Eom, Kidong; Yoon, Hakyoung

    2017-06-16

    A 14-year-old dog weighing 4 kg presented with hypotension only in the right forelimb. Thoracic radiography revealed a round soft tissue opacity near the aortic arch and below the second thoracic vertebra on a lateral view. Three-dimensional computed tomography angiography clearly revealed stenosis and aneurysmal dilation of an aberrant right subclavian artery. Stenosis and aneurysm of an aberrant subclavian artery should be included as a differential diagnosis in dogs showing a round soft tissue opacity near the aortic arch and below the thoracic vertebra on the lateral thoracic radiograph.

  2. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah; Given, Mark F.; McGrath, Frank P.; Lee, Michael J., E-mail: mlee@rcsi.ie [Beaumont Hospital, Department of Radiology (Ireland)

    2015-06-15

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrade puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.

  3. Isolated Subclavian Vein Injury: A Rare and High Mortality Case

    Directory of Open Access Journals (Sweden)

    Sahin Iscan

    2013-01-01

    Full Text Available Isolated subclavian vein injuries are rarely seen without concomitant arterial injury, bone fracture, damage to brachial plexus, and thoracal traumas. Our case was brought to the emergency service 6 hours after he had been shot at the shoulder with a firearm. After detection of extravasation from the left axillary and subclavian vein on arteriographic and venographic examinations, he was operated on. An autogenous saphenous vein graft was interposed between subclavian and axillary veins. Cardiac arrest developed twice because of hypovolemia, which was resolved with medical therapy. Subclavian vein injuries have a more mortal course when compared with the injuries to the subclavian arteries. Its most important reason is excessive blood loss and air embolism because of delayed arrival to hospital. As is the case in all vascular injuries, angiography is the most important diagnostic examination. If the general health state of the patient permits, arteriography and venography should be performed in patients potentially exposed to vascular injuries. In patients with extreme blood loss and deteriorated health state, direct surgical exploration of the injury site, containment of the bleeding, and venous repair are life-saving approaches.

  4. Sheath rendezvous method: a novel distal protection technique during endovascular treatment of subclavian artery occlusions.

    Science.gov (United States)

    Haraguchi, Takuya; Urasawa, Kazushi; Nakama, Tatsuya; Nakagawa, Yuya; Tan, Michinao; Koshida, Ryoji; Sato, Katsuhiko

    2016-10-01

    To describe an innovative distal protection technique, "sheath rendezvous method", during endovascular treatment for subclavian arterial occlusions. 4.5F and 6F guiding sheath were inserted from left brachial and common femoral artery, respectively. 0.014″ guidewire retrogradely passed through occlusion and into antegrade sheath to establish a pull-through system. 3.0 mm balloon was used to expand occlusion and anchor to deliver retrograde sheath into antegrade one. Both sheaths locked by balloon dilatation crossed occlusion until antegrade sheath passed over lesion. Balloon expandable stent was delivered within antegrade sheath. Sheath was removed, and stent was implanted. We obtained an excellent outcome without complications.

  5. Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures

    International Nuclear Information System (INIS)

    Nicholson, Tony; Ettles, Duncan; Robinson, Graham

    2004-01-01

    Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred with carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device

  6. Subclavian steal syndrome without subclavian stenosis

    Directory of Open Access Journals (Sweden)

    Matt Cwinn, MD

    2017-09-01

    Full Text Available Subclavian steal syndrome (SSS has been well described in the setting of subclavian stenosis. We describe an unusual case of SSS caused by a high-flow arteriovenous dialysis fistula in the absence of subclavian stenosis, provide a review of the literature, and propose that arteriovenous fistula-induced SSS is an underdiagnosed cause of syncope in this population of patients.

  7. Under X-ray guidance stent implantation through retrograde popliteal artery puncturing for the treatment of superficial femoral artery occlusion: the initial results in nine cases

    International Nuclear Information System (INIS)

    He Xu; Gu Jianping; Lou Wensheng; Chen Liang; Chen Guoping; Su Haobo; Song Jinhua; Wang Tao; Xu Ke

    2011-01-01

    Objective: To discuss the application of retrograde popliteal artery puncturing under X-ray guidance in the interventional therapy for superficial femoral artery occlusion. Methods: Retrograde popliteal artery puncturing under X-ray guidance was carried out in nine patients with long-segment occlusion of superficial femoral artery as antegrade recanalization via femoral artery approach had failed in them. After retrograde route was successfully established, the balloon dilation and subsequent stent placement for occluded vessel were performed. Results: The technical success was obtained in all patients. The occluded superficial femoral arteries were reopened and the symptoms of intermittent claudication disappeared. No serious complications such as injuries of adjacent nerves or vessels occurred. The ankle-brachial index (ABI) increased from preoperative (0.38±0.13) to postoperative (0.92±0.11) with the difference being statistically significant (P<0.01). A follow-up period lasting for 2-16 months was conducted. Eleven months after the treatment, intermittent claudication recurred in one case, and CT angiography showed that the distal part of the stent was narrowed. The symptoms were improved after percutaneous transcatheter angioplasty was performed again. Conclusion: Retrograde popliteal artery puncturing under X-ray guidance is an effective and safe technique for the treatment of superficial femoral artery long-segment occlusion with stent placement, especially for patients in whom antegrade recanalization via femoral artery approach fails. (authors)

  8. Vapocoolant Spray Effectiveness on Arterial Puncture Pain: A Randomized Controlled Clinical Trial

    Directory of Open Access Journals (Sweden)

    Shervin Farahmand

    2017-02-01

    Full Text Available Arterial blood gas (ABG sampling is a painful procedure with no perfect technique for quelling the discomfort. An ideal local anesthesia should be rapid, easy to learn, inexpensive, and noninvasive. This study was aimed to compare pain levels from ABG sampling performed with vapocoolant spray in comparison to placebo. We hypothesized that pretreatment with the vapocoolant would reduce the pain of arterial puncture by at least 1 point on a 10 point verbal numeric scale. We have evaluated the effectiveness of a vapocoolant spray in achieving satisfactory pain control in patients undergoing ABG sampling in this randomized placebo controlled trial. Eighty patients were randomized to 2 groups: group A, who received vapocoolant spray, and group B, who received water spray as placebo (Control group. Puncture and spray application pain was assessed with numerical rating scale (0, the absence of pain; 10, greatest imaginable pain and number of attempts was recorded. The pain score during ABG sampling was not lower in group A compared with group B significantly (4.78±1.761 vs. 4.90±1.837; P:0.945. This study showed that while the spray exerts more application pain, the number of attempts required for ABG sampling was not significantly lower in group A compared with group B (1.38±0.54 vs. 1.53±0.68; P=0.372. Vapocoolant spray was not effective in ABG pain reduction, had milder application pain compared to placebo (P<0.05, but did not reduce sampling attempts. At present, this spray cannot be recommended for arterial puncture anesthesia, and further study on different timing is necessary.

  9. Influence of Mechanical Ventilation on the Incidence of Pneumothorax During Infraclavicular Subclavian Vein Catheterization: A Prospective Randomized Noninferiority Trial.

    Science.gov (United States)

    Kim, Eugene; Kim, Hyun Joo; Hong, Deok Man; Park, Hee-Pyoung; Bahk, Jae-Hyon

    2016-09-01

    It remains unclear whether we have to interrupt mechanical ventilation during infraclavicular subclavian venous catheterization. In practice, the clinicians' choice about lung deflation depends on their own discretion. The purpose of this study was to assess the influence of mechanical ventilation on the incidence of pneumothorax during infraclavicular subclavian venous catheterization. A total of 332 patients, who needed subclavian venous catheterization, were randomly assigned to 1 of the 2 groups: catheterizations were performed with the patients' lungs under mechanical ventilation (ventilation group, n = 165) or without mechanical ventilation (deflation group, n = 167). The incidences of pneumothorax and other complications such as arterial puncture, hemothorax, or catheter misplacements and the success rate of catheterization were compared. The incidences of pneumothorax were 0% (0/165) in the ventilation group and 0.6% (1/167) in the deflation group. The incidence of pneumothorax in the deflation group was 0.6% higher than that in the ventilation group and the 2-sided 90% confidence interval for the difference was (-1.29% to 3.44%). Because the lower bound for the 2-sided 90% confidence interval, -1.29%, was higher than the predefined noninferiority margin of -3%, the inferiority of the ventilation group over the deflation group was rejected at the .05 level of significance. Other complication rates and success rates of catheterization were comparable between 2 groups. The oxygen saturation dropped below 95% in 9 patients in the deflation group, while none in the ventilation group (P = .007). The success and complication rates were similar regardless of mechanical ventilation. During infraclavicular subclavian venous catheterization, interruption of mechanical ventilation does not seem to be necessary for the prevention of pneumothorax.

  10. Balloon catheter dilatation in the treatment of the subclavian steal syndrome

    International Nuclear Information System (INIS)

    Arlart, I.P.

    1988-01-01

    The present paper reports on the results of PTA in the treatment of subclavian steal syndrome and significant proximal subclavian artery stenosis in thirteen patients. In all cases, it was possible to dilate the stenoses successfully and without complications. Cerebral symptoms caused by the steal phenomenon (seven patients) were relieved in all cases and ischaemic symptoms in the arms produced by exercise were cured in ten out of eleven patients. Balloon catheter dilatation of proximal subclavian stenosis in symptomatic patients is the treatment of choice, as judged by our own experience and the data in the literature. (orig.) [de

  11. Irradiation-induced changes in the subclavian and axillary arteries after radiotherapy for carcinoma of the breast

    International Nuclear Information System (INIS)

    Kretschmer, G.; Niederle, B.; Polterauer, P.; Waneck, R.

    1986-01-01

    Three case reports are reviewed to illustrate the possibility of treating irradiation-induced lesions of the subclavian-brachial vascular segment (aneurysm and segmental occlusions) 14, 20, and 26 years after radical mastectomy and subsequent radiotherapy. All patients had an extraanatomic vein bypass graft from the carotid to the brachial artery crossing the shoulder near the acromioclavicular joint, with the advantage that the tissue changed by radiotherapy or infected by ulceration could be circumvented. There were no postoperative complications, with adequate function of the grafts (follow-up, 17, 24, and 20 months, respectively)

  12. Supraclavicular versus Infraclavicular Subclavian Vein Catheterization in Infants

    Directory of Open Access Journals (Sweden)

    Wen-Hsien Lu

    2006-04-01

    Conclusion: In our study, we found that there was no statistically significant difference among the 4 SVC locations in effectiveness of operation or in risk of complication. There was a tendency to damage the subclavian arteries through the supraclavicular route.

  13. Espessamento médio-intimal na origem da artéria subclávia direita como marcador precoce de risco cardiovascular Intima-media thickness in the origin of right subclavian artery as an early marker of cardiovascular risk

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Engelhorn

    2006-11-01

    EMI na origem da artéria subclávia direita pode ser considerado um marcador mais precoce para avaliação de risco cardiovascular.OBJECTIVE: Common carotid artery intima-media thickness (IMT is considered a factor of cardiovascular risk and an early marker of coronary artery disease. This study aimed to investigate the existence of a correlation between IMT in the carotid arteries and at the origin of the right subclavian artery, as well as to evaluate IMT in the subclavian artery as an earlier marker of cardiovascular risk. METHODS: One hundred and six consecutive patients, 52 males and 54 females, average age 51 years, underwent color Doppler ultrasonography to evaluate carotid and right subclavian arteries. The relationship between carotid IMT and right subclavian IMT was assessed using the Pearson's correlation coefficient analysis and a 95% confidence interval. Reliability of right subclavian artery IMT measurement for the diagnosis of early thickening (considering a > 0.8 mm carotid thickness as reference was described as to sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. Cut-off values for the right subclavian IMT were indicated by the ROC curve, and p values 0.8 mm. The mean IMT value for the carotid artery was 0.87 mm (SD = 0.23 and for the subclavian artery, 1.17 mm (SD = 0.46, with a 0.31 correlation coefficient (95% CI: 0.12; 0.47. The ROC curve analysis indicated a cut-off value of 0.7 mm for the right subclavian artery IMT, using as reference a 0.8 mm cut-off value for the carotid artery (91% sensitivity, 27% specificity, 66% PPV, 65% NPV, and 66% accuracy. CONCLUSION: Our study showed that carotid artery IMT correlates well with right subclavian artery IMT. With a 0.7 mm cut-off value, it is possible to detect IMT in the right subclavian artery earlier than in the carotid arteries. The IMT at the origin of the right subclavian artery can be considered an earlier marker for the assessment of cardiovascular

  14. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  15. Aneurysmatic dissection of an aberrant right subclavian artery; Disseziierendes Aneurysma einer aberranten Arteria subclavia dextra: Diagnose mittels Ultrafast-CT

    Energy Technology Data Exchange (ETDEWEB)

    Reittner, P. [Universitaetsklinik fuer Radiologie, Graz (Austria). Abt. fuer Allgemeine Radiologie; Stacher, R. [Universitaetsklinik fuer Radiologie, Graz (Austria). Abt. fuer Allgemeine Radiologie

    1996-01-01

    Diagnosis with Ultrafast-CT: An aneurysm of an aberrant right subclavian artery is a very rare cause for dysphagia. We describe such a case in a 67-year-old patient, diagnosed with Ultrafast-CT and discuss it together in concert with the embryology and the radiological findings. (orig.) [Deutsch] Eine aberrierende Arteria subclavia dextra ist eine seltene Ursache fuer Dysphagie. Anhand eines 67jaehrigen Patienten werden Embryologie und radiologische Charakteristika, diagnostiziert mittels Ultrafast-CT, diskutiert. (orig.)

  16. Ultrasound guided implantation of chest port systems via the lateral subclavian vein

    International Nuclear Information System (INIS)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K.; Warm, M.; Reiser, M.; Toex, U.

    2006-01-01

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  17. [Subclavian artery rupture after road crash: many similitaries].

    Science.gov (United States)

    Rulliat, E; Ndiaye, A; David, J-S; Voiglio, E J; Lieutaud, T

    2011-12-01

    Traumatic Subclavian Arterial Ruptures (TSCAR) are rare and with a poor prognosis. The aim of this study was to describe the epidemiological data and the medical charts of the initial care of each patient suffering a TSCAR following a traffic accident. Using the register of the road crash in the Rhone department (France) that records every casualty using the AIS codes, we retrospectively reviewed the prehospital and intrahospital medical, biological and radiological charts of every patient. Follow-up was obtained at day 60 post-trauma. Among the 1181 severe traumatic injuries, five casualties have been recorded in the register with a TSCAR (0.4%). Four of the five patients died in an early dramatic fatal hemorrhagic shock. Similarities between casualties were observed for patients still alive at hospital arrival that associate 1) a two-wheel motorized rider (2-WMR) crashing without antagonist 2) a severe polytraumatism including thoracic and 3) orthopaedic lesions; 4) clinical and biological signs of a severe haemorrhagic shock; 5) radiological signs of scapulothoracic dissociation. TSCAR are rare with a high mortality. We recommend improving the early care by the recognition of the triad associating early severe shock, polytraumatism (thorax and superior limb) and radiological signs evocating scapulothoracic dissociation in a 2-WMR. These signs must lead to the operating theatre as fast as possible in association with early massive transfusions. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  18. A conservative approach to a thoracic duct injury caused by left subclavian vein catheterization

    Directory of Open Access Journals (Sweden)

    Vedran Premuzic

    2018-01-01

    Full Text Available Thoracic duct injury is a rare complication of left subclavian vein catheterization. A significant injury could lead to chylothorax, a condition with high mortality rate if not treated. It is diagnosed with lymphography or by laboratory tests of pleural fluid aspirate. A 51 year old Caucasian male with a history of unregulated hypertension presented to our Emergency department (ED with anginous symptoms and increased serum creatinine level. After the placement of a temporary central venous catheter for hemodialysis in left subclavian vein, he developed lymph leakage on puncture site beside the catheter, at drainage rate of 75 ml/h. In the absence of more serious clinical symptoms, conservative treatment with close patient monitoring and diet changes was chosen, rather than more invasive treatment options.

  19. The zero-wall puncture: a novel angiographic puncture technique with substantial benefits

    International Nuclear Information System (INIS)

    Leswick, D.A.; Szkup, P.; Stoneham, G.W.

    2005-01-01

    Medical education can be busy, exhausting, and stressful, with potential adverse effects on trainees' physical and mental health. Radiology residency is no exception. In addition to increased daily workload and study requirements, Canadian radiology residents are performing a diverse and increasing number of emergent diagnostic examinations after hours. In an attempt to improve resident self-worth and efficiency during angiographic rotations, we investigated the effects of a novel angiographic puncture procedure on various resident lifestyle indexes. Standard techniques for accessing the femoral artery are either the single-wall puncture or double-wall puncture (Seldinger technique). Both of these techniques are widely known and practiced. Following procedure completion, hemostasis must be achieved at the puncture site. This has traditionally required manual compression at the puncture site, which may require 15 to 20 minutes. At our institution the standard policy is that 'whoever makes the puncture, compresses the groin,' also known as 'you broke it, you fix it'. This has prompted our industrious resident complement to develop a novel, previously undescribed, angiographic puncture technique known as the 'zero-wall puncture technique.' Preliminary unpublished results from our institution show that when residents employ the zero-wall puncture technique the attending staff radiologist subsequently both performs the puncture and compresses the groin at the end of the procedure. We investigated the effect of zero-wall puncture on various resident lifestyle indexes. (author)

  20. Intrathoracic lipoma masquerading as subclavian artery trauma.

    LENUS (Irish Health Repository)

    Munro, P T

    2012-02-03

    A 58 year old man was admitted to the accident and emergency department following an industrial accident in which he sustained a three part fracture dislocation of his right humerus. Chest radiography revealed a large mass in the right upper hemithorax and, when the patient became hypotensive, an emergency thoracotomy was performed. The mass was found to be a massive intrathoracic lipoma. This case shows how preexisting intrathoracic lesions may be mistaken for subclavian or great vessel trauma following violent shoulder girdle injury. The differential diagnosis of traumatic and non-traumatic intrathoracic mass lesions in chest radiography should be considered carefully.

  1. Hybrid treatment of dysphagia lusoria: right carotid to subclavian bypass and endovascular insertion of an Amplatzer II Vascular Plug

    Directory of Open Access Journals (Sweden)

    Ernesto Cobos-González

    Full Text Available Compression of the esophagus by a retroesophageal aberrant right subclavian artery (ARSA is a rare cause of dysphagia. We present the case of a 47-year-old female with symptoms of progressive dysphagia diagnosed with dysphagia lusoria using barium swallow and contrast computed tomography and successfully treated with a hybrid procedure: right carotid to subclavian bypass and endovascular insertion of an Amplatzer II Vascular Plug through the right superficial femoral artery. We consider this approach safer, less invasive and more complete to avoid recurrent dysphagia.

  2. Complications of the lateral C1-C2 puncture myelography for cervical spinal canal

    International Nuclear Information System (INIS)

    Mihale, J.; Traubner, P.

    1998-01-01

    This reviewed the complications of 106 patients of the lateral C1-C2 puncture myelography for cervical spinal canal and cervical spinal cord disorders. Spinal cord puncture and contrast injection, puncture between the occiput and C1, and blood vessel puncture were the main complications. These principally depended on the misdirection of the X ray beam. For preventing major arterial puncture determined the pathway of the vertebral arteries and incidence of anomaly. (authors)

  3. Retrograde vs. Antegrade Puncture for Infra-Inguinal Angioplasty

    International Nuclear Information System (INIS)

    Nice, C.; Timmons, G.; Bartholemew, P.; Uberoi, R.

    2003-01-01

    This study was done to compare antegrade punctures with a retrograde puncture technique for infrainguinal angioplasty. A group of 100 consecutive patients (71 men, 29 women) were randomized for antegrade puncture or retrograde puncture of the common femoral artery. Following retrograde puncture the guidewire was 'turned' and placed into the superficial femoral artery. The time for gaining access, screening time, radiation dose, patient height, weight and complications were recorded. All patients were reviewed the day after the procedure and within 3 months. Data from 46 patients (34 males and 12 females) in the retrograde group and 44 (28 males and 16 females) in the antegrade group were available for analysis. Mean procedure time,screening time, radiation dose, height and weight were 8.3 minutes(range 3-22), 2.1 minutes (0.3-6.5), 7950 mGy cm -2 (820-71250), 169 cm (149-204) and 79 kg (32-108) for retrograde puncture and 8 min (2-60), 0.7 min (0.0-3.2), 1069 mGycm -2 (0-15400), 169 cm (152-186) and 75 kg (39-125) for antegrade punctures, respectively. An average of 1.2 (1-2) punctures was required for retrograde and 1.75 (1-8) for antegrade. Seven small hematomas occurred with antegrade and three for retrograde puncture.Retrograde puncture is technically easier with a tendency to fewer complications but results in a higher radiation dose. This technique should be used in difficult patients at high risk of haematoma formation

  4. Efficiency comparison of 3 kinds of arterial puncture closing devices

    International Nuclear Information System (INIS)

    Feng Xiaodi; Jin Xian; Chen Yueguang; Xiao Hongbing; Yu Qiang; Chen Chengjun; Zhang Dadong

    2007-01-01

    Objective: To evaluate the efficiencies of arterial puncture closing devices (APCDs) including Angioseal, Perclose and Boomerang in patients undergone coronary angiography or percutaneous vascular interventions. Methods: 1497 patients underwent cardiac catheterization procedures were divided into manual compression group(639 cases) and APCDs closure group (576 cases with Angioseal, 151 cases Perclose and 11.3 cases of Boomerang). The times of maneuver, hemorrhage complication and other rare complications were assessed, recorded and compared. Results: The times for maneuver of standard manual compression group, Angioseal group, Perclose group and Boomerang group were (21.4±2.7) h, (3.5±2.3) h, (3.7± 2.6) h and (3.9±2.8) h respectively. The APCDs could obviously reduce bed rest time in comparing to that of manual compression. The rates of failure of the operations were 2.7%, 1.4%, 8.6% and 3.5% (P =0.006, P<0.001); and the rates of hemorrhage were 9.2%, 5.8%, 12.6% and 8.0% respectively for each of the four mentioned groups (P=0.005). Except the failure operations, the incidence of hemorrhage complications among the groups showed no significant differences. Conclusion: Application of APCDs to close the puncture site can significantly reduce the bed rest time, but not the incidence of hemorrhage complications. (authors)

  5. Percutaneous transluminal angioplasty of stenoses of the proximal subclavian artery

    International Nuclear Information System (INIS)

    Grote, R.; Freyschmidt, J.; Walterbusch, G.; Medizinische Hochschule Hannover

    1983-01-01

    Between August 1980 and June 1982, 12 left-sided proximal subclavian stenoses were dilated with balloon catheters. The dilatation was successful in all patients. Differences in blood pressure in the arm could be demonstrated subsequently. Recurrences occurred in two patients after seven and eleven months. Follow-up of nine patients up to 24 months showed them to be symptom-free. (orig.)

  6. Successful treatment of direct carotid-cavernous fistula in a patient with Ehlers-Danlos syndrome type IV without arterial puncture: the transvenous triple-overlay embolization (TAILOREd) technique.

    Science.gov (United States)

    Huynh, Thien J; Morton, Ryan P; Levitt, Michael R; Ghodke, Basavaraj V; Wink, Onno; Hallam, Danial K

    2017-08-18

    We report successful transvenous treatment of direct carotid-cavernous fistula in a patient with Ehlers-Danlos syndrome type IV using a novel triple-overlay embolization (TAILOREd) technique without the need for arterial puncture, which is known to be highly risky in this patient group. The TAILOREd technique allowed for successful treatment using preoperative MR angiography as a three-dimensional overlay roadmap combined with cone beam CT and live fluoroscopy, precluding the need for an arterial puncture. 2017 BMJ Publishing Group Ltd.

  7. The Use of ExoSeal Vascular Closure Device for Direct Antegrade Superficial Femoral Artery Puncture Site Hemostasis

    Energy Technology Data Exchange (ETDEWEB)

    Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Khaitovich, Boris, E-mail: borislena@012.net.il [Tel-Aviv University, Diagnostic and Interventional Imaging Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel); Yakubovich, Dmitry, E-mail: Dmitry.Yakubovitch@sheba.health.gov.il [Tel-Aviv University, Vascular Surgery Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel); Bensaid, Paul, E-mail: paulbensaid@hotmail.com; Golan, Gil, E-mail: gilgolan201@gmail.com [Tel-Aviv University, Diagnostic and Interventional Imaging Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel); Silverberg, Daniel, E-mail: Daniel.Silverberg@sheba.health.gov.il [Tel-Aviv University, Vascular Surgery Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel)

    2015-06-15

    PurposeThis study was designed to assess the efficacy and safety of the ExoSeal vascular closure device (VCD) to achieve hemostasis in antegrade access of the superficial femoral artery (SFA).MethodsWe retrospectively reviewed the outcome of ExoSeal VCD used for hemostasis in 110 accesses to the SFA in 93 patients between July 2011 and July 2013. All patients had patent proximal SFA based on computer tomography angiography or ultrasound duplex. Arterial calcifications at puncture site were graded using fluoroscopy. The SFA was accessed in an antegrade fashion with ultrasound or fluoroscopic guidance. In all patients, 5–7F vascular sheaths were used. The ExoSeal VCD was applied to achieve hemostasis at the end of the procedure. All patients were clinically examined and had ultrasound duplex exam for any puncture site complications during the 24 h postprocedure.ResultsIn all procedures, the ExoSeal was applied successfully. We did not encounter any device-related technical failure. There were four major complications in four patients (3.6 %): three pseudoaneurysms, which were treated with direct thrombin injection, and one hematoma, which necessitated transfusion of two blood units. All patients with complications were treated with anticoagulation preprocedure or received thrombolytic therapy.ConclusionsThe ExoSeal VCD can be safely used for antegrade puncture of the SFA, with a high procedural success rate (100 %) and a low rate of access site complications (3.6 %)

  8. Prospective Nonrandomized Trial of Manual Compression and Angio-Seal and Starclose Arterial Closure Devices in Common Femoral Punctures

    International Nuclear Information System (INIS)

    Ratnam, Lakshmi A.; Raja, Jowad; Munneke, Graham J.; Morgan, Robert A.; Belli, Anna-Maria

    2007-01-01

    We compared the use of manual compression and Angio-Seal and Starclose arterial closure devices to achieve hemostasis following common femoral artery (CFA) punctures in order to evaluate safety and efficacy. A prospective nonrandomized, single-center study was carried out on all patients undergoing CFA punctures over 1 year. Hemostasis was achieved using manual compression in 108 cases, Angio-Seal in 167 cases, and Starclose in 151 cases. Device-failure rates were low and not significantly different in the two groups (manual compression and closure devices; p = 0.8). There were significantly more Starclose (11.9%) patients compared to Angio-Seal (2.4%), with successful initial deployment subsequently requiring additional manual compression to achieve hemostasis (p < 0.0001). A significant number of very thin patients failed to achieve hemostasis (p = 0.014). Major complications were seen in 2.9% of Angio-Seal, 1.9% of Starclose, and 3.7% of manual compression patients, with no significant difference demonstrated; 4.7% of the major complications were seen in female patients compared to 1.3% in males (p = 0.0415). All three methods showed comparable safety and efficacy. Very thin patients are more likely to have failed hemostasis with the Starclose device, although this did not translate into an increased complication rate. There is a significant increased risk of major puncture-site complications in women with peripheral vascular disease

  9. Concomitant Avulsion Injury of the Subclavian Vessels and the Main Bronchus Caused by Blunt Trauma.

    Science.gov (United States)

    Noh, Dongsub; Lee, Chan-Kyu; Hwang, Jung Joo; Cho, Hyun Min

    2018-04-01

    Concomitant rupture of the subclavian vessels and the left main bronchus caused by blunt trauma is a serious condition. Moreover, the diagnosis of a tracheobronchial injury with rupture of the subclavian vessels can be difficult. This report describes the case of a 33-year-old man who suffered from blunt trauma that resulted in the rupture of the left subclavian artery and vein. The patient underwent an operation for vascular control. On postoperative day 3, the left main bronchus was found to be transected on a computed tomography scan and bronchoscopy. The transected bronchus was anastomosed in an end-to-end fashion. He recovered without any notable problems. Although the bronchial injury was not detected early, this case of concomitant rupture of the great vessels and the airway was successfully treated after applying extracorporeal membrane oxygenation.

  10. The Effect of a Third Generation Hemostatic Dressing in a Subclavian Artery and Vein Transection Porcine Model

    Science.gov (United States)

    2014-04-01

    small skin incision. The exposed subclavian vessels were treated with lidocaine , transected and allowed to free bleed for thirty seconds prior to...achieve hemorrhage control (Butler & Blackbourne, 2012) is typically ineffective in this region because pressure over the clavicle will not be...cavity depth, and cavity volume. The subclavian vessels were then immersed in 30 mL of 2% lidocaine (Phoenix Pharmaceuticals, St. Joseph, MO) for 10

  11. A Case of Duplicated Right Vertebral Artery.

    Science.gov (United States)

    Motomura, Mayuko; Watanabe, Koichi; Tabira, Yoko; Iwanaga, Joe; Matsuuchi, Wakako; Yoshida, Daichi; Saga, Tsuyoshi; Yamaki, Koh-Ichi

    2018-04-27

    We encountered a case of duplicated right vertebral artery during an anatomical dissection course for medical students in 2015. Two vertebral arteries were found in the right neck of a 91-year-old female cadaver. The proximal leg of the arteries arose from the area between the right subclavian artery and the right common carotid artery that diverged from the brachiocephalic artery. The distal leg arose from the right subclavian artery as expected. The proximal leg entered the transverse foramen of the fourth cervical vertebra and the distal leg entered the transverse foramen of the sixth cervical vertebra. The two right vertebral arteries joined to form one artery just after the origin of the right vertebral artery of the brachiocephalic artery entered the transverse foramen of the fourth cervical vertebra. This artery then traveled up in the transverse foramina and became the basilar artery, joining with the left vertebral artery. We discuss the embryological origin of this case and review previously reported cases.

  12. PHACE association with intracranial, oropharyngeal hemangiomas, and an atypical patent ductus arteriosus arising from the tortuous left subclavian artery in a premature infant

    Directory of Open Access Journals (Sweden)

    Do-Hyun Kim

    2012-01-01

    Full Text Available PHACE association is a rare neurocutaneous condition in which facial hemangiomas associate with a spectrum of posterior fossa malformations, arterial cerebrovascular anomalies, cardiovascular anomalies, and eye anomalies. We reported a case of PHACE association in a premature infant showing facial, intracranial, and oropharyngeal hemangiomas with evidence of the Dandy-Walker variant and complicated cardiovascular anomalies, including a right-sided aortic arch and an atypical patent ductus arteriosus arising from a tortuous left subclavian artery. To our knowledge, intracranial hemangiomas are rare in PHACE association, and a concomitant oropharyngeal hemangioma has not been previously reported in the PHACE association literature. In infants presenting with large, plaque-like facial hemangiomas, it is important to conduct active cardiovascular and neurological evaluations. Special attention should be given to the laryngoscopic examination to search for additional hemangiomas in the airway.

  13. Multi-detector row computed tomographic evaluation of a rare type of complete vascular ring: Double aortic arch with atretic left arch distal to the origin of left subclavian artery

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Ying Ying; Fu, Ching Yun; Wei, Hao Ji; Tsai, I Chen; Chen, Clayton Chi Chang [Taichung Veterans General Hospital, Taichung (China)

    2013-10-15

    Double aortic arch with an atretic left arch distal to the origin of left subclavian artery was diagnosed with multi-detector row computed tomography (MDCT) in two children with dysphagia. This rare type of complete vascular ring is clinically important because it may be confused with right aortic arch in mirror imaging. Anatomic details of this rare type of complete vascular ring demonstrated on MDCT facilitated appropriate surgical treatment.

  14. Management strategies for thoracic stent-graft repair of distal aortic arch lesions: is intentional subclavian artery occlusion a safe procedure?

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio; Salvatori, Filippo Maria; Pucci, Armando; Lucatelli, Pierleone; Rossi, Plinio; Passariello, Roberto [University of Rome La Sapienza, Department of Radiological Sciences, Rome (Italy); Dake, Michael D. [Stanford University School of Medicine, Department of Cardiothoracic Surgery Radiology, Stanford, CA (United States); Mazzesi, Giuseppe [University of Rome La Sapienza, Institute of Heart and Great Vessels, Rome (Italy)

    2009-10-15

    The aim of this retrospective analysis was to assess the clinical consequences after intentional left subclavian artery (LSA) occlusion. Thirty-seven patients, 27 type B dissection and 10 thoracic aneurysm, with short proximal neck (less than 2 cm) underwent endovascular treatment with intentional exclusion of LSA origin. No immediate complications occurred. Mean arterial pressure gradient, between right and left arms, ranged from 15 to 45 mmHg. After a mean follow-up of 43.70{+-}24.01 months, mild left arm symptoms secondary to flow reduction occurred in eight cases (21.6%) but only one required LSA transposition, after 8 months, for visual impairment. Type II endoleaks from excluded LSA occurred in 10 cases (27.0%): in seven patients, leaks were treated with coils and/or glue embolization; in one case, leak sealed spontaneously; one patient died before leak embolization could occur; one patient refused any further treatment. Intentional exclusion of the LSA may be justified when a longer proximal landing zone in the aortic arch is required. (orig.)

  15. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  16. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    International Nuclear Information System (INIS)

    Ahmed, Ahmed T.; Mohammed, Khaled; Chehab, Monzer; Brinjikji, Waleed; Hassan Murad, M.; Cloft, Harry; Bjarnason, Haraldur

    2016-01-01

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  17. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Ahmed T., E-mail: Ahmed.Ahmed1@mayo.edu; Mohammed, Khaled, E-mail: Mohammed.Khaled@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Chehab, Monzer, E-mail: moe.chehab@beumont.edu [Oakland University William Beaumont School of Medicine, Department of Diagnostic Radiology and Molecular Imaging (United States); Brinjikji, Waleed, E-mail: Brinjikji.Waleed@mayo.edu [Mayo Clinic, Department of Radiology (United States); Hassan Murad, M., E-mail: Murad.Mohammad@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Cloft, Harry, E-mail: Cloft.Harry@mayo.edu; Bjarnason, Haraldur, E-mail: Bjarnason.Haraldur@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2016-05-15

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  18. Percutaneous transluminal angioplasty (PTA) of supra-aortic arteries especially the internal carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Kachel, R.; Basche, S. (Medizinische Akademie, Erfurt (Germany, F.R.). Radiologische Klinik); Heerklotz, I.; Grossmann, K. (Medizinische Akademie, Erfurt (Germany, F.R.). Klinik fuer Innere Medizin); Endler, S. (Medizinische Akademie, Erfurt (Germany, F.R.). Klinik fuer Neurologie und Psychiatrie)

    1991-06-01

    We present our experience with 105 patients in whom percutaneous transluminal angioplasty was performed in 112 stenosed or occluded supra-aortic arteries. Symtoms of cerebrovascular and/or vertebrobasilar insufficiency were present in 104 of the 105 patients. The angioplasty was successful in 35 stenoses of the internal carotid artery, 2 stenoses of the common carotid artery, 1 stenosis of the external carotid artery, 15 stenoses of the vertebral artery, 3 stenoses of the innominate artery and 44 stenoses of the subclavian artery. There were only 4 minor-complications (2 haematomas, 1 transient ischemic attack, 1 small thrombus of the internal carotid artery which was detected by 111-indium platelet scintigraphy and treated by thrombendarterectomy before the appearance of neurological symptoms). All patients were symptom free after angioplasty. During the observations period of 3 to 109 months (average 58 months) there were only two cases with re-stenosis after subclavian angioplasty. The results of more than 700 personal and international published percutaneous transluminal angioplasties of supra-aortic arteries are presented. The results suggest that angioplasty of supra-aortic arteries is an effective method. On strict definition of the indications, the complication rate for angioplasty of the supra-aortic arteries is not likely to be higher than that for operative treatment. (orig.).

  19. Ultrasound guided implantation of chest port systems via the lateral subclavian vein; Die sonographisch gezielte Implantation von Portkathetersystemen ueber die laterale Vena subclavia

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K. [Inst. fuer Radiologische Diagnostik, Univ. zu Koeln (Germany); Warm, M. [Gynaekologie, Univ. zu Koeln (Germany); Reiser, M. [Medizinische Klinik I, Univ. zu Koeln (Germany); Toex, U. [Medizinische Klinik IV, Univ. zu Koeln (Germany)

    2006-03-15

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  20. Changes in cerebral haemodynamics in cases of post-lumbar puncture headache: a prospective transcranial Doppler ultrasound study

    International Nuclear Information System (INIS)

    Goebel, H.; Klostermann, H.; Lindner, V.; Schenkl, S.

    1990-01-01

    Transcranial Doppler ultrasonography was used in 45 patients to investigate if changes in haemodynamics in the major arteries of the brain base occurred after lumbar puncture and whether or not patients with or without post-lumbar puncture headache differ with respect to their cerebral haemodynamic parameters before and after lumbar puncture. Before lumbar puncture, patients with post-lumbar puncture headache differed from patients withoput post-lumbar puncture headache in that they showed significantly higher flow velocities and significant asymmetry of flow velocities with lateralization to the right. Patients without post-lumbar puncture headache, on the other hand, showed non-significant flow velocity lateralization to the left. Forty-eight hours after lumbar puncture, both groups demonstrated symmetrical flow velocities. In addition, only patients with post-lumbar puncture headache showed a significant reduction in the flow velocity of the right middle cerebral artery. These findings suggest that it is not only absolute flow velocity that plays a part in the event of headache; the interhemispheric relation of cerebral haemodynamics also plays a fundamental role. 14 refs., 3 figs., 2 tabs

  1. Pseudoaneurysms of large arteries associated with AIDS

    Directory of Open Access Journals (Sweden)

    Carlos Eli Piccinato

    Full Text Available BACKGROUND: Several vascular complications are known to occur in association with the acquired immunodeficiency syndrome (AIDS and recent publications have called attention to the development of pseudoaneurysms of large arteries in patients with AIDS. CASE REPORT: We report on 2 patients with AIDS aged 23 and 31 years with pseudoaneurysms of the abdominal aorta and common iliac arteries. After clinical and radiological evaluation by arteriography and computed tomography, the patients were submitted to aneurysmectomy, with the placement of a patch of dacron in the first case and the interposition of a right aorto-iliac and left femoral prosthesis in the second. The second patient developed new aneurysms of the right subclavian and left popliteal arteries 2 months after surgery. Proximal ligation of the right subclavian artery was performed to treat the first aneurysm and resection and interposition of a reversed saphenous vein was carried out to treat the pseudoaneurysm of the popliteal artery. Histopathological examination of the popliteal artery revealed necrotizing arteritis.

  2. The transradial approach for selective carotid and vertebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, S.; Ueda, K.; Sueyosi, S.; Nagasawa, M.; Ude, K. [Higashiosaka City General Hospital, Osaka (Japan). Dept. of Radiology; Yokoyama, K. [Higashiosaka City General Hospital, Osaka (Japan). Dept. of Neurosurgery; Takayama, K.; Nakagawa, H.; Kichikawa, K. [Nara Medical Univ., Osaka (Japan). Dept. of Radiology

    2002-11-01

    Purpose: The transradial approach is not so popular in cerebral angiography. The purpose of this study was therefore to present our experience of success rate and safety of this method. Material and Methods: From December 1998 to June 2001, 526 carotid and vertebral angiographies with DSA were performed via the radial artery. A 1.4-mm catheter was used through a 1.4-mm introducer sheath. We evaluated the procedure as successful if sufficient images for diagnosis were obtained of the bilateral carotid arteries and unilateral vertebral artery. Each patient was reassessed for any complications, occurring until the next morning. The length of time needed for an examination was measured in the last 10 cases. Results: In all but 5 cases, the procedures were evaluated as successful (99.0%). Unsuccessful cases manifested severe pain at the radial puncture, angiospasm at the radial artery, loop formation at the radial artery, occlusion at the subclavian artery, and an aberrant right subclavian artery. No severe complications including neurological ones were encountered. Minor complications were noted in 17 cases (3.2%): 4 cases of thrombus at the ulnar artery, 1 angiospasm at the radial artery, and 12 cases of small hematoma at the puncture site. The radial approach took 14 min less in the common carotid study and 3 min 30 s less in the internal carotid study than by the femoral approach. Conclusion: The transradial approach enabled selective studies for carotid and vertebral angiography with a high success rate and safety with few complications.

  3. The transradial approach for selective carotid and vertebral angiography

    International Nuclear Information System (INIS)

    Iwasaki, S.; Ueda, K.; Sueyosi, S.; Nagasawa, M.; Ude, K.; Yokoyama, K.; Takayama, K.; Nakagawa, H.; Kichikawa, K.

    2002-01-01

    Purpose: The transradial approach is not so popular in cerebral angiography. The purpose of this study was therefore to present our experience of success rate and safety of this method. Material and Methods: From December 1998 to June 2001, 526 carotid and vertebral angiographies with DSA were performed via the radial artery. A 1.4-mm catheter was used through a 1.4-mm introducer sheath. We evaluated the procedure as successful if sufficient images for diagnosis were obtained of the bilateral carotid arteries and unilateral vertebral artery. Each patient was reassessed for any complications, occurring until the next morning. The length of time needed for an examination was measured in the last 10 cases. Results: In all but 5 cases, the procedures were evaluated as successful (99.0%). Unsuccessful cases manifested severe pain at the radial puncture, angiospasm at the radial artery, loop formation at the radial artery, occlusion at the subclavian artery, and an aberrant right subclavian artery. No severe complications including neurological ones were encountered. Minor complications were noted in 17 cases (3.2%): 4 cases of thrombus at the ulnar artery, 1 angiospasm at the radial artery, and 12 cases of small hematoma at the puncture site. The radial approach took 14 min less in the common carotid study and 3 min 30 s less in the internal carotid study than by the femoral approach. Conclusion: The transradial approach enabled selective studies for carotid and vertebral angiography with a high success rate and safety with few complications

  4. Endovascular repair of inadvertent arterial injury induced by central venous catheterization using a vascular closure device: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Hee; Jang, Woo Jin; Oh, Ju Heyon; Song, Yun Gyu [Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon (Korea, Republic of)

    2017-04-15

    Central venous catheterization can cause various complications. Inadvertent subclavian artery catheterization was performed during insertion of a central venous catheter in a 73-year-old man suffering from panperitonitis due to small-bowel perforation. Endovascular treatment was conducted to treat the injured subclavian artery with a FemoSeal vascular closure device.

  5. Impact of femoral artery puncture using digital subtraction angiography and road mapping on vascular and bleeding complications after transfemoral transcatheter aortic valve implantation.

    Science.gov (United States)

    El-Mawardy, Mohamed; Schwarz, Bettina; Landt, Martin; Sulimov, Dmitriy; Kebernik, Julia; Allali, Abdelhakim; Becker, Bjoern; Toelg, Ralph; Richardt, Gert; Abdel-Wahab, Mohamed

    2017-01-20

    The use of large-diameter sheaths carries the risk of significant vascular and bleeding complications after transfemoral transcatheter aortic valve implantation (TAVI). In this analysis, we sought to assess the impact of a modified femoral artery puncture technique using digital subtraction angiography (DSA) and road mapping during transfemoral TAVI on periprocedural vascular and bleeding events. This is a retrospective analysis of transfemoral TAVI patients included in a prospective institutional database. The modified femoral artery puncture technique using DSA-derived road mapping guidance was introduced in October 2012. Before the introduction of this technique, vascular puncture was acquired based on an integration of angiographic data, the bony iliofemoral landmarks and a radiopaque object. Consecutive patients who underwent TAVI with the road mapping technique (RM group, n=160) were compared with consecutive patients who underwent TAVI without road mapping (control group, n=160) prior to its introduction. A standardised strategy of periprocedural anticoagulation was adopted in both groups as well as the use of a single suture-based closure device. All endpoints were defined according to the VARC-2 criteria for event definition. The mean age in the RM group was 80±7.7 years compared to 81±5.9 years in the control group (p=0.19), and females were equally distributed between both groups (63.1% vs. 58.1%, p=0.36). The baseline logistic EuroSCORE was 20.7±14.4% vs. 24.9±15.2% in the RM and control group, respectively (p=0.01). Notably, sheath size was significantly larger in the RM compared to the control group due to the more frequent use of the 20 Fr sheath (23.8% vs. 1.8%, proad map group but did not reach statistical significance (8.1% vs. 13.8%, p=0.1). Other forms of vascular and bleeding complications as well as all-cause mortality were comparable in both groups. A modified femoral artery puncture technique using DSA and road mapping was associated

  6. TrapEase inferior vena cava filter placement: use of the subclavian vein.

    Science.gov (United States)

    Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A

    2004-01-01

    The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access

  7. Imaging the vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Davies, John R.; Weissberg, Peter L. [Addenbrooke' s Hospital and University of Cambridge, Division of Cardiovascular Medicine, Cambridge (United Kingdom); Gillard, Jonathan H. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospitald, University Department of Radiology, Cambridge (United Kingdom)

    2005-07-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  8. Imaging the vertebral artery

    International Nuclear Information System (INIS)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M.; Davies, John R.; Weissberg, Peter L.; Gillard, Jonathan H.

    2005-01-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  9. Arterial supply of the thoracic lobes of the thymus in dogs of the Great Dane race.

    Directory of Open Access Journals (Sweden)

    Rosana Marques Silva

    2007-09-01

    Full Text Available The origins, numbers and type of arterial branches responsible for the blood supply of thoracic lobes of the thymus were studied in 28 stillborn dogs of the Great Dane, of which 18 were males and 10 were females. The arterial systems of these animals were filled with aqueous solution of Neoprene Latex “450”, 50%. After, the specimens were fixed in 10% formaldehyde aqueous solution. The lobes of the thymus were supplied by direct or indirect arterial branches coming from the right and left internal thoracic arteries, pericardiacophrenicas arteries, right and left costocervicais trunks, and left subclavian artery. The left subclavian artery and brachiocephalic trunk emitted direct branches towards the left thoracic lobe of the thymus.

  10. Rabbit models of cerebral vasospasm established with endovascular puncture

    International Nuclear Information System (INIS)

    Tu Jianfei; Liu Yizhi; Ji Jiansong; Zhao Zhongwei

    2008-01-01

    Objective: To investigate the method of endovascular puncture to establish rabbit models of cerebral vasospasm. Methods: New Zealand white rabbits were divided into 5 groups (12 h, 1 d, 2 d, 3 d and 7 d) randomly, and each group was separated into subarachnoid hemorrhage (SAH) subgroup (n=5) and control subgroup (n=2). cerebral vascular spasm (CVS) models were established after SAH with endovascular puncture. CT scans before and after operation were performed. The internal diameters and the wall thicknesses of posterior communicans artery (PcoA) and basilar artery (BA) were measured with HE stain after the animals were executed. Results: CVS model was successfully eastblished in 35 rabbits (SAH subgroup 25, control subgroup 10), resulting a successful rate of 48.61%. Compared with control subgroup, PcoA and BA showed shrinkage of internal diameters of 43.60% and 51.82% 12 h after SAH, respectively, and the shrinkage appeared as biphasic patterns until the 7th study day with another peaks of 29.32% and 45.19%, respectively. Conclusions: Endovascular puncture is an effective method to establish rabbit of CVS. The death rate of animals can be decreased with the asage of new interventional material and perfection for the details of operation. (authors)

  11. Hemodynamics in stented vertebral artery ostial stenosis based on computational fluid dynamics simulations.

    Science.gov (United States)

    Qiao, Aike; Dai, Xuan; Niu, Jing; Jiao, Liqun

    2016-01-01

    Hemodynamic factors may affect the potential occurrence of in-stent restenosis (ISR) after intervention procedure of vertebral artery ostial stenosis (VAOS). The purpose of the present study is to investigate the influence of stent protrusion length in implantation strategy on the local hemodynamics of the VAOS. CTA images of a 58-year-old female patient with posterior circulation transient ischemic attack were used to perform a 3D reconstruction of the vertebral artery. Five models of the vertebral artery before and after the stent implantation were established. Model 1 was without stent implantation, Model 2-5 was with stent protruding into the subclavian artery for 0, 1, 2, 3 mm, respectively. Computational fluid dynamics simulations based on finite element analysis were employed to mimic the blood flow in arteries and to assess hemodynamic conditions, particularly the blood flow velocity and wall shear stress (WSS). The WSS and the blood flow velocity at the vertebral artery ostium were reduced by 85.33 and 35.36% respectively after stents implantation. The phenomenon of helical flow disappeared. Hemodynamics comparison showed that stent struts that protruded 1 mm into the subclavian artery induced the least decrease in blood speed and WSS. The results suggest that stent implantation can improve the hemodynamics of VAOS, while stent struts that had protruded 1 mm into the subclavian artery would result in less thrombogenesis and neointimal hyperplasia and most likely decrease the risk of ISR.

  12. Contemporary management of civilian penetrating cervicothoracic arterial injuries.

    Science.gov (United States)

    Weinberg, Jordan A; Moore, Andrew H; Magnotti, Louis J; Teague, Rebecca J; Ward, Tyler A; Wasmund, Joshua B; Lamb, Elena M P; Schroeppel, Thomas J; Savage, Stephanie A; Minard, Gayle; Maish, George O; Croce, Martin A; Fabian, Timothy C

    2016-08-01

    The management of arterial injury at the thoracic outlet has long hinged on the fundamental principles of extensile exposure and vascular anastomosis. Nonetheless, treatment options for such injuries have evolved to include both endovascular stent placement and temporary vascular shunts. The purpose of this study was to evaluate our recent experience with penetrating cervicothoracic arterial injuries in light of these developments in trauma care. Patients with penetrating injuries to the innominate, carotid, subclavian, or axillary arteries managed at a single civilian trauma center between 2000 and 2013 were categorized as the modern era (ME) cohort. The management strategies and outcomes pertaining to the ME group were compared to those of previously reported experience (PE) concerning injuries to the innominate, carotid, subclavian, or axillary arteries at the same institution from 1974 to 1988. Over the two eras, there were 202 patients: 110 in the ME group and 92 in the PE group. Most of the injuries in both groups were managed with primary repair (45% vs. 46%; p = 0.89). A similar proportion of injuries in each group was managed with anticoagulation alone (14% vs. 10%; p = 0.40). In the ME group, two cases were managed with temporary shunt placement, and endovascular stent placement was performed in 12 patients. Outcomes were similar between the groups (bivariate comparison): mortality (ME, 15% vs. PE, 14%; p = 0.76), amputation following subclavian or axillary artery injury (ME, 5% vs. PE, 4%; p = 0.58), and posttreatment stroke following carotid injury (ME, 2% vs. PE, 6%; p = 0.57). Experience with penetrating arterial cervicothoracic injuries at a high-volume urban trauma center remained remarkably similar with respect to both anatomic distribution of injury and treatment. Conventional operative exposure and repair remain the cornerstone of treatment for most civilian cervicothoracic arterial injuries. Therapeutic study, level V.

  13. Hemodynamic effects of innominate artery occlusive disease on anterior cerebral artery.

    Science.gov (United States)

    Tan, Teng-Yeow; Lien, Li-Ming; Schminke, Ulf; Tesh, Paul; Reynolds, Patrick S; Tegeler, Charles H

    2002-01-01

    Stenoses of the innominate artery (IA) may affect flow conditions in the carotid arteries. However, alternating flow in ipsilateral anterior cerebral artery (ACA) due to IA stenosis is extremely rare. A 49-year-old woman who was evaluated for symptomatic cerebrovascular disease presented with right latent subclavian and right carotid system steal. Transcranial Doppler examination displayed systolic deceleration wave-forms in the right terminal internal carotid artery and alternating flow in the right ACA. Magnetic resonance angiography demonstrated tight stenosis of the right IA. For a thorough study of the hemodynamic effects of IA stenosis, a combination of duplex and transcranial Doppler examination is required.

  14. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    International Nuclear Information System (INIS)

    Too, Chow Wei; Sayani, Raza; Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva; Teo, Terence K.

    2016-01-01

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  15. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    Energy Technology Data Exchange (ETDEWEB)

    Too, Chow Wei, E-mail: toochowwei@gmail.com [Singapore General Hospital (Singapore); Sayani, Raza [Aga Khan University Hospital (Pakistan); Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva [Singapore General Hospital (Singapore); Teo, Terence K. [Mount Elizabeth Novena Hospital (Singapore)

    2016-08-15

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  16. Technical note: subclavian artery misplacement of a 12F Shaldon catheter: percutaneous repair with a local closure device under temporary balloon tamponade; Technische Mitteilung: Entfernung eines fehlplatzierten 12F Shaldon Katheters aus der A. subclavia und Abdichtung mittels Verschlusssystem bei temporaerer Ballonblockade

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, J.E.; Katoh, M.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Fussen, R. [Anaesthesiologische Klinik, Medizinisches Zentrum Kreis Aachen GmbH (Germany)

    2006-06-15

    A case of subsequent percutaneous repair using a local closure device with a collagen block (VasoSeal {sup registered}) and temporary balloon tamponade after inadvertent subclavian artery misplacement of a 12F Shaldon catheter is reported. Balloon occlusion safely prevented displacement of collagen into the vascular lumen by occluding the 12F entry site. Furthermore, collagen-induced coagulation was facilitated. (orig.)

  17. A systematic study of the brain base arteries in the rabbit (Oryctolagus cuniculus

    Directory of Open Access Journals (Sweden)

    Fernanda de Souza

    2013-06-01

    Full Text Available The brains of 30 New Zealand rabbits (Oryctolagus cuniculus were injected with red stained latex. The arteries of the ventral surface of the brain were systematized on the right (R and on the left (L side with the respective percentage of appearance: the aortic arch emitted the braquicephalic trunk and the left subclavian artery (83.3%; or the braquicephalic trunk, the left common carotid artery and the left subclavian artery (16.7%. The braquicephalic trunk emitted the right and the left common carotid arteries and the right subclavian artery (83.3%; or the right common carotid artery and the right subclavian artery (16.7%. The common carotid arteries were divided into external and internal carotid arteries (96.7% on the R, 100% on the L.. The internal carotid artery to the R was present (96.7% and absent (3.3%, and to the L, was present (100%. The rostral choroidal artery to the R was collateral branch of the rostral branch of the internal carotid artery (83.3%, collateral branch of caudal branch of the internal carotid artery (16.7%, and to the L was collateral branch of the rostral branch of the internal carotid artery (93.3%, collateral branch of the caudal branch of the internal carotid artery (6.7%. The middle cerebral artery to the R and to the L was single (80% and double (20%. The rostral cerebral artery to the R had middle caliber (90%, thin caliber (6.7% and too thin caliber (3.3%, and to the L had middle caliber (76.7%, thin caliber (16.7% and too thin caliber (6.7%. The internal ethmoidal artery was absent (73.3%, present and single (26.7%. The caudal cerebral artery to the R was single (66.7%, double (26.7% and triple (6.7%, and to the L was single (63.3% and double (36.7%. The terminal branches of the right and left vertebral arteries were present (100%, and formed the basilar artery (100%. The ventral spinal artery was present (100%. The caudal cerebellar artery, to the R was single (43.3%, single with labyrinthic artery

  18. Prediction of subclavian vein location using plain chest radiography.

    Science.gov (United States)

    Fukutome, T; Shigematsu, A

    1986-12-01

    The relationship between the right subclavian vein and the thoracic inlet below the clavicle was studied by Venography in 72 patients. The area of the thoracic inlet below the clavicle was defined as a radiolucent area surrounded superiorly by the lower border of the clavicle, inferiorly by the inner margin of the first rib and medially by the lateral margin of the manubrium (CRM area). In 10 patients, the subclavian vein was situated below the axis of the clavicle, and the CRM area was large enough to extend near the top of the first rib arch. In 62 patients, the subclavian vein extended above the axis of the clavicle and the CRM area was small or invisible. The existence of a large thoracic inlet below the clavicle (large CRM area which extends near the top of the first rib arch) may be a useful indicator for predicting the low location of the subclavian vein, and may be used to predict or explain venipuncture failure using the standard infraclavicular approach.

  19. The arterial supply of the thymus in dogs

    Directory of Open Access Journals (Sweden)

    Frederico Ozanan Carneiro e Silva

    1994-06-01

    Full Text Available There were observed the origin, the number and the ordering of the thymic vessels in 30 dogs fetuses, by dissection after injection with Neoprene latex 450 solution and fixation with formalin solution at 10%. The results permited to conclude that: the thymic arteries come, directly and indirectly, from the internal thoracic arteries, brachiocephalic trunk, pericardicophrenics arteries, costocervicals trunks and subclavian arteries, wich combined by theirself given from five to fourteen contributions that showed a own vascularization model for each organ.

  20. INTERRUPTION OF THE AORTIC-ARCH, DISTAL AORTOPULMONARY WINDOW, ARTERIAL DUCT AND AORTIC ORIGIN OF THE RIGHT PULMONARY-ARTERY IN A NEONATE - REPORT OF A CASE SUCCESSFULLY REPAIRED IN A ONE-STAGE OPERATION

    NARCIS (Netherlands)

    BOONSTRA, PW; EBELS, T

    The case of a 4-day-old male neonate with the rare combination of interruption of the aortic arch beyond the left subclavian artery, distal aortopulmonary window, persistent arterial duct and aortic origin of the right pulmonary artery is presented. Review of the literature reveals this patient to

  1. Incidentally diagnosed Takayasu arteritis on thyroid ultrasonography showing prominent collateral vessels of thyroidal arteries and common carotid artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Se Jin; Kim, Eun Kyung [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    We report a case of middle-aged woman incidentally diagnosed with Takayasu arteritis during the ultrasonography of a thyroid gland nodule. Prominent collaterals of the thyroidal arteries and a thin common carotid artery with mural thickening and deficient intraluminal flow signals were initially depicted on the ultrasonography with color Doppler. Subsequent magnetic resonance angiography and computed tomography aortography confirmed the diagnosis with the imaging features of a bilateral long segment common carotid artery occlusion and segmental stenosis of the left subclavian artery in addition to the suggestive physical findings.

  2. CT-guided puncture

    International Nuclear Information System (INIS)

    Noeldge, G.; Richter, G.M.; Grenacher, L.; Brado, M.; Kauffmann, G.W.

    1996-01-01

    Sonographic and CT-guided punctures allow the evaluation of suspected lesions in the head, thorax, abdomen, retroperitoneum and skeletal system. The size of the lesion to be evaluated determines the size and the diameter of the puncture needle. The quantity of the material obtained will be defined by the diameter of the needle, i.e. fine-needle biopsy is more adequate for cytological than for histological evaluation. Strict adherence to the indications and contraindications for puncture and painstaking performance of the procedure go a long why towards minimizing the complications. The advantage of CT-guided puncture, in contrast to an ultrasound-guided procedure, is visualization during the puncture procedure free from overshadowing. This permits punctures of lesions located deep in the thorax or the abdomen which are overshadowed by the lungs, by air in the small or large bowel or by bone structures. Moreover, this technique yields much more information about the tissues and organs surrounding the suspected lesion. This information is much more investigator-related with ultrasoundguided puncture. Therefore, the CT-guided puncture has become mandatory in the evaluation of suspected lesions. Moreover, using the same technique, percutaneous drainage of fluids in the interpleural space, abscesses in organs, hematomas, lymphoceles and urinomas; ablation of metastases; and sympathicolysis can be carried out. CT-guided puncture thus changes from a minimally invasive diagnostic procedure to a minimally invasive therapy. (orig./MG) [de

  3. Combined jugular and subclavian vein thrombosis following assisted reproductive technology--new observation.

    Science.gov (United States)

    Salomon, Ophira; Schiby, Ginette; Heiman, Zehava; Avivi, Kamila; Sigal, Carol; Levran, David; Dor, Jeushua; Itzchak, Yacov

    2009-08-01

    To study the predilection of jugular and subclavian vein thrombosis in patients going through assisted reproductive technology (ART). This technology puts women at high risk of developing the ovarian hyperstimulation syndrome (OHSS) and thrombotic events. Study cases. Large Academic Medical Center. Five women who developed jugular and subclavian vein thrombosis following ART were included in the study. The deep vein thrombosis was demonstrated by ultrasound Doppler or computerized tomography angiography. All women were interviewed and data obtained from outpatient and hospital medical charts. Magnetic resonance imaging and complete thrombophilic profile workup was performed in each woman. Open biopsy from the lesions was taken from one of the women. Correlation between mechanical branchial cysts filled with fluid during OHSS and jugular and subclavian vein thrombosis. Five women developed jugular and subclavian vein thrombosis following ART. They were found to harbor clusters of rudimentary branchial cysts filled with fluid at the time of OHSS, which compressed the jugular and subclavian veins at their junction at the base of the neck. Four patients (80%) were found to be carriers of factor V Leiden. Predilection of jugular and subclavian vein thrombosis early in pregnancy is the result of mechanical compression mediated by rudimentary branchial cysts filled with fluid during OHSS, particularly in subjects who are carriers of factor V Leiden.

  4. A new cerebral vasospasm model established with endovascular puncture technique

    International Nuclear Information System (INIS)

    Tu Jianfei; Liu Yizhi; Ji Jiansong; Zhao Zhongwei

    2011-01-01

    Objective: To investigate the method of establishing cerebral vasospasm (CVS) models in rabbits by using endovascular puncture technique. Methods: Endovascular puncture procedure was performed in 78 New Zealand white rabbits to produce subarachnoid hemorrhage (SAH). The survival rabbits were randomly divided into seven groups (3 h, 12 h, 1 d, 2 d, 3 d, 7 d and 14 d), with five rabbits in each group for both study group (SAH group) and control group. Cerebral CT scanning was carried out in all rabbits both before and after the operation. The inner diameter and the thickness of vascular wall of both posterior communicating artery (PcoA) and basilar artery (BA) were determined after the animals were sacrificed, and the results were analyzed. Results: Of 78 experimental rabbits, CVS model was successfully established in 45, including 35 of SAH group and 10 control subgroup. The technical success rate was 57.7%. Twelve hours after the procedure, the inner diameter of PcoA and BA in SAH group was decreased by 45.6% and 52.3%, respectively, when compared with these in control group. The vascular narrowing showed biphasic changes, the inner diameter markedly decreased again at the 7th day when the decrease reached its peak to 31.2% and 48.6%, respectively. Conclusion: Endovascular puncture technique is an effective method to establish CVS models in rabbits. The death rate of experimental animals can be decreased if new interventional material is used and the manipulation is carefully performed. (authors)

  5. Subclavian steal syndrome: treatment by percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Abath, Carlos Gustavo Coutinho; Silva, Marcos Antonio Barbosa da; Brito, Norma Maria Tenorio; Marques, Silvio Romero; Santa Cruz, Rodolfo

    1995-01-01

    The subclavian steal syndrome is a rare vascular disease that can be managed by interventional radiology. It is presented the experience with three cases of this syndrome that underwent percutaneous transluminal angioplasty, and a brief literature review is done. Two patients remained asymptomatic 23 and 30 months, respectively, after the procedure. One patient presented with recurrent symptoms 12 months after the dilatation. Considering the low morbidity and good clinical and technical results, percutaneous transluminal angioplasty is the first choice in the subclavian steal syndrome treatment. (author). 9 refs., 3 figs

  6. Femoral Artery Stenosis Following Percutaneous Closure Using a Starclose Closure Device

    International Nuclear Information System (INIS)

    Bent, Clare Louise; Kyriakides, Constantinos; Matson, Matthew

    2008-01-01

    Starclose (Abbott Vascular Devices, Redwood City, CA) is a new arterial closure device that seals a femoral puncture site with an extravascular star-shaped nitinol clip. The clip projects small tines into the arterial wall which fold inward, causing the arterial wall to pucker, producing a purse-string-like seal closing the puncture site. The case history is that of a 76-year-old female patient who underwent day-case percutaneous diagnostic coronary angiography. A Starclose femoral artery closure device was used to achieve hemostasis with subsequent femoral artery stenosis.

  7. Internal Thoracic Artery Encircled by an Unusual Phrenic Nerve Loop

    Directory of Open Access Journals (Sweden)

    Robert Fu-Chean Chen

    2007-12-01

    Full Text Available We report an anatomic variation of the phrenic nerve. During a routine gross anatomical dissection course at our medical university, we found an unusual loop of the left phrenic nerve around the internal thoracic artery, about 1 cm from the take-off of the left subclavian artery. The phrenic nerve is close to the internal thoracic artery and is easily injured when dissecting the internal thoracic artery for coronary artery bypass conduit. Therefore, we suggest that the anatomic relationship of the phrenic nerve and internal thoracic artery is important in preventing incidental injury of the phrenic nerve.

  8. Permanent Cortical Blindness After Bronchial Artery Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Doorn, Colette S. van, E-mail: cvandoorn@gmail.com; De Boo, Diederick W., E-mail: d.w.deboo@amc.uva.nl [Academic Medical Centre, Department of Radiology (Netherlands); Weersink, Els J. M., E-mail: e.j.m.weersink@amc.uva.nl [Academic Medical Centre, Department of Pulmonology (Netherlands); Delden, Otto M. van, E-mail: o.m.vandelden@amc.uva.nl; Reekers, Jim A., E-mail: j.a.reekers@amc.uva.nl; Lienden, Krijn P. van, E-mail: k.p.vanlienden@amc.uva.nl [Academic Medical Centre, Department of Radiology (Netherlands)

    2013-12-15

    A 35-year-old female with a known medical history of cystic fibrosis was admitted to our institution for massive hemoptysis. CTA depicted a hypertrophied bronchial artery to the right upper lobe and showed signs of recent bleeding at that location. Bronchial artery embolization (BAE) was performed with gelfoam slurry, because pronounced shunting to the pulmonary artery was present. Immediately after BAE, the patient developed bilateral cortical blindness. Control angiography showed an initially not opacified anastomosis between the embolized bronchial artery and the right subclavian artery, near to the origin of the right vertebral artery. Cessation of outflow in the bronchial circulation reversed the flow through the anastomosis and allowed for spill of embolization material into the posterior circulation. Unfortunately the cortical blindness presented was permanent.

  9. A Limb-Threatening Long Arterial Dissection Caused by Humerus Neck Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Kurnaz R

    2018-03-01

    Full Text Available Proximal humerus fracture is a common arm trauma and rarely occurs with vascular injury which however is a serious complication. In this case report, we present a long segment dissection of the axillary and brachial arteries as a rare complication due to fragmented proximal humerus fracture and shoulder dislocation. An 80-year old female patient was seen at the emergency department. Radiograph examination has revealed a fragmented proximal humerus fracture besides dislocation of the head of humerus towards the axillary area. On vascular examination, acute arterial occlusion such as absence of radial and ulnar pulses were observed in her left hand. The patient was immediately taken to the operating room. The dissection included the entire segment approximately 20cm between the distal subclavian artery and the distal brachial artery. This injured segment was removed and a 6mm Polytetrafluroethylene (PTFE graft with rings was interpositoned between subclavian and brachial arteries. This case is a rarity because of such a significant complication after a small injury. Axillary artery injuries caused by humeral neck fractures are rare but should not be missed by the physician.

  10. Music and 25% glucose for preterm babies during the pre-procedure for arterial puncture: facial mimics emphasis

    Directory of Open Access Journals (Sweden)

    Maria Vera Lúcia Moreira Leitão Cardoso

    2016-06-01

    Full Text Available We aimed to describe and quantify facial mimic movements of preterm babies during music and 25% glucose interventions at the pre-procedure for arterial puncture. A randomized controlled trial involving 48 videos of preterm attended in a public neonatal unit, in Fortaleza – Ceará. We collected data from footage analyses during the pre-procedure. Babies heard a lullaby song for 10 minutes in the experimental group; we administered 25% glucose in the control group at the end of the eighth minute, matching a total of 10 minutes of observation. We assessed the frequency of facial expressions: cry, sneeze, yawn, frown the forehead, focused sight, vague sight, sleeping and head movement. Statistically significant variable for the control group: vague sight (p=0.001 at the two last minutes of observation. We concluded that there was no association between most of facial movements and the studied interventions, except for a vague sight in the control group.

  11. Angioplasty in stenosis of the innominate artery

    International Nuclear Information System (INIS)

    Kobinia, G.S.; Bergmann, H. Jr.

    1983-01-01

    We describe a successful percutaneous transluminal dilatation (PTD) of an innominate artery stenosis in a 40-year-old patient with aortic arch syndrome. Five years earlier both a left central carotid artery occlusion and an innominate and left subclavian artery stenosis were treated by grafting from the aorta to the distal vessels. At recurrence of the neurological symptoms, reocclusion of the graft to the innominate artery and subtotal stenosis of the left carotid anastomosis were noted. The prevent the hazards of a reoperation, the innominate artery stenosis was dilated by means of PTD via the right brachial artery. Success of the procedure was demonstrated by Doppler sonography and angiography. It appears that PTD serves as an excellent method of treating stenoses of the aortic arch branches in aortic arch syndrome. (orig.)

  12. Nonbronchial systemic arteries: incidence and endovascular interventional management for hemoptysis

    International Nuclear Information System (INIS)

    Jiang Sen; Zhu Xiaohua; Sun Xiwen; You Zhengqian; Ma Jun; Yu Dong; Peng Gang; Jie Bing; Sun Chunyi

    2009-01-01

    Objective: To investigate the incidence and relation to primary diseases of the nonbronchial systemic arteries (NBSA) supply to the pulmonary lesions, and to evaluate the clinical value of transcatheter arterial embolization (TAE) of the responsibly NBSA for hemoptysis. Methods: The aortography and subclavian artery angiography were performed in 139 patients with hemoptysis, including pulmonary tuberculosis in 66 cases (2 cases with post-thoracoplasty, 1 case with post-lobectomy, and 1 case with ventricular septal defect), bronchiectasis in 41 (1 case with post-lobectomy and 1 case with post-ligation of patent ductus arteriosus), bronchiogenic carcinoma in 15, unknown hemoptysis in 7, silicosis in 3, broncholithiasis in 3, bronchial cysts in 1, empyema in 1, postoperative lung cancer in 1, and chronic pulmonary embolism in 1, respectively. TAE was performed in patients with the discoverable responsible NBSA. The frequency, distribution and relation to primary diseases of the responsible NBSA were evaluated and the clinical results and complications were observed. Follow-up time ranged from 6 months to 5 years. Results: Seventy-three patients (52.5%) had nonbronchial systemic contributions, including 5 cases of post-thoracotomy with pulmonary lesions, 1 case complicating with ventricular septal defect, 1 case with post-ligation of patent ductus arteriosus, and 1 case of chronic pulmonary embolism. The total number of NBSA were 181 including posterior intercostal arteries (n=88), internal thoracic arteries (n=27), inferior phrenic arteries (n=21), proper esophageal arteries (n=20), lateral thoracic arteries (n=9), subscapular arteries (n=7), costocervical trunks (n=5) and thyrocervical trunks (n=4). Main responsible NBSA were posterior intercostal arteries (n=75) and branches of subclavian and axillary artery (n=44) in patients with pulmonary tuberculosis, and proper esophageal arteries (n=16) and inferior phrenic arteries (n=17) in bronchiectasis. The clinical

  13. FEATURES OF FORMATION OF COLLATERAL CIRCULATION IN PATIENTS WITH SUBCLAVIAN STEAL SYNDROME.

    Science.gov (United States)

    Kopolovets, I; Štefanič, P; Rusyn, V; Tóth, Š; Mashura, V; Berek, P

    2017-12-01

    To date in patients with subclavian steal syndrome diagnosis is only grade of stenosis or localization of occlusion described. Authors recommend to take into account also type of a collateral compensation of cerebral circulation for selection of an optimal treatment The objective of the research was to study the features of formation of collateral circulation in patients with subclavian steal syndrome. The authors described changes in the direction of blood flow in the extracranial vessels of 42 patients with subclavian steal syndrome. Latent subclavian steal syndrome was detected in 26.2% of patients, transient subclavian steal syndrome was found in 54.8% of patients, and a persistent course of the disease was observed in 19.9% of patients. Symptoms of vertebrobasilar insufficiency were detected in 26.6% of patients, and combination of chronic upper extremity ischemia and vertebrobasilar insufficiency was diagnosed in 73.8% of patients. When analyzing the features of collateral circulation in 64.3% of patients the extracranial compensatory mechanism was observed being provided by three main groups of collateral hemodynamic reallocation: the occipito-vertebral hemodynamic mechanism of compensation was detected in 38.1% of cases, the thyroid compensatory mechanism was found in 16.7% of cases, and the brain stem-occipital compensatory mechanism was observed in 9.5% of cases. In 35.7% of patients the intracranial compensatory mechanism was observed being provided by two main groups of collateral hemodynamic reallocation: the vertebro-vertebral compensatory mechanism was found in 21.4% of cases and cerebrobasilar compensatory mechanism was detected in 14.3% of cases. Consideration of the features of collateral circulation in patients with subclavian steal syndrome may serve as a prognostic criterion for selecting an optimal treatment tactics.Each of compensatory mechanisms has its own hemodynamic peculiarities. The occipito- vertebral compensatory mechanism has the

  14. Thrombosis caused by polyurethane double-lumen subclavian superior vena cava catheter and hemodialysis

    DEFF Research Database (Denmark)

    Wanscher, Maria Rørbæk; Frifelt, J J; Smith-Sivertsen, C

    1988-01-01

    During an 18-month period, 82 consecutive patients (37 women and 45 men), with a mean age of 50 yr (range 15 to 74), underwent hemodialysis with 91 polyurethane double-lumen subclavian superior vena cava catheters inserted via the right subclavian vein. Upon catheter removal, venograms were...

  15. Puncture panel optimization

    International Nuclear Information System (INIS)

    Glass, R.E.; Longenbaugh, R.S.

    1986-01-01

    Sandia National Laboratories developed the TRansUranic PACkage Transporter (TRUPACT) to transport defense contact-handled transuranic wastes. The package has been designed to meet the normal and hypothetical accident conditions in 10CFR71 which includes the demonstrated ability to survive a 1-meter drop onto a mild steel pin. The puncture protection is provided by puncture resistant panels. In conjunction with the development of TRUPACT, a series of experiments has been conducted to reduce the weight of the puncture resistant panels. The initial scoping tests resulted in a preliminary design incorporating 30 layers of Kevlar. This design has been shown to meet the regulatory puncture test. To reduce the weight of this panel, subscale tests were conducted on panels utilizing Kevlar yarns with varying mass per unit length (denier) as well as different resins. This paper reviews the testing undertaken in the original panel development and discusses the results obtained from the recent subscale and full-scale optimization tests

  16. Direct stent puncture technique for intraluminal stent recanalization in the superficial femoral and popliteal arteries in-stent occlusion: Outcomes from a prospective clinical analysis of diabetics with critical limb ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Palena, Luis Mariano, E-mail: marianopalena@hotmail.com; Manzi, Marco

    2013-07-15

    Purpose: To evaluate the efficacy and safety of “Direct Stent Puncture” technique for intraluminal stent recanalization in the femoro-popliteal segments. Methods and Materials: A cohort of diabetics who had symptomatic in-stent occlusion of the superficial femoral or popliteal arteries underwent endovascular recanalization. After antegrade failure, direct stent puncture technique was performed. The primary end-point was to efficacy assessment, intended as technical success and clinical improvement. The secondary end-point was safety assessment, intended as free of complication rate. Results: Fifty-four patients (37 men; 73.6 ± 8.5 years) underwent direct stent puncture technique, after several unsuccessful antegrade attempts to cross the occluded stent. Technical success for intraluminal stent recanalization was achieved in 53/54 (98.2%) of cases and failed in 1/54 (1.8%). Clinical improvement was obtained in 51/54 (94.4%) of cases, with regression of the clinical symptoms and improvement of the TcPO{sub 2}, from 3 ± 18 mmHg to 43 ± 11 mmHg after 15 days (p < 0.001). Free of complications rate was 92.5%. In 2/54 (3.7%) of cases distal embolization occurred, in 1/54 (1.9%) case a sudden vessel thrombosis was diagnosed after 12 hours and in 1/54 (1.9%) case hematoma at the stent puncture site was observed. Conclusions: Direct Stent Puncture technique is an efficacy and safety option for intraluminal stent recanalization in the femoro-popliteal segment in-stent occlusion.

  17. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    Shindoh, Noboru; Ozaki, Yutaka; Kyogoku, Shinsuke; Yamana, Daigo; Sumi, Yukiharu; Katayama, Hitoshi

    1999-01-01

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  18. Access to the Superficial Femoral Artery in the Presence of a 'Hostile Groin': A Prospective Study

    International Nuclear Information System (INIS)

    Marcus, Adrian J.; Lotzof, Kevin; Howard, Adam

    2007-01-01

    Purpose. Lower limb angioplasty is commonly performed via antegrade common femoral artery (CFA) puncture, followed by selective superficial femoral artery (SFA) catheterization. Arterial access can be complicated by a 'hostile groin' (scarring, obesity, or previous failed CFA puncture). We prospectively investigated color duplex ultrasound (CDU)-guided SFA access for radiological interventions. Methods. Antegrade CDU-guided CFA and SFA puncture were compared in 30 patients requiring intervention for severe leg ischemia who had hostile groins. Demographics, screen time, radiation dose, intervention, and complications were prospectively recorded. Results. Treatment in 30 patients involved 44 angioplasties (40 transluminal, 4 subintimal) and 2 diagnostic angiograms. Fifteen of these patients had CDU-guided CFA punctures; in 8 of these patients CDU-guided CFA puncture 'failed' (i.e., there was failure to pass a guidewire or catheter into the CFA or SFA), necessitating immediate direct CDU-guided SFA puncture. Overall, the mean screen time and radiation dosage, via direct CDU-guided SFA puncture in 30 patients, was 4.8 min and 464 Gy cm 2 respectively. With CDU-guided CFA puncture, mean screen time (10 min), radiation dose (2023 Gy cm 2 ), and complications (13%) were greater when compared with the SFA puncture results overall and in the same patients at subsequent similar procedures (2.7 min, 379 Gy cm 2 (p < 0.05), no complications in this subgroup). Five complications occurred: 2 each at CFA and SFA entry sites, and 1 angioplasty embolus. Conclusions. The CDU-guided SFA puncture technique was both more effective than CDU-guided CFA access in patients with scarred groins, obesity, or failed CFA punctures and safer, with reduced screen times, radiation doses, and complications

  19. Complications and nursing care in interventional treatment of diabetic foot via radial artery access

    International Nuclear Information System (INIS)

    Liu Lingyun; Zhou Xiaoxiang; Zeng Yongmei; Chen Junfei; Lai Lisha; Pang Pengfei; Zhu Kangshun

    2009-01-01

    Objective: To evaluate the therapeutic effect of interventional treatment via radial artery access for diabetic foot and to summarize its complications and nursing care. Methods: The interventional treatment via radial artery access was performed in twenty patients with diabetic foot. The preoperative psychological nursing care, the nursing of the punctured site of radial artery and the indwelling catheter, the complications of the puncture site and thrombolytic therapy were reviewed and retrospectively analyzed. Results: Some complications occurred in eight cases, including hematoma at puncture site (n= 1), oozing of blood (n=3), gingival bleeding (n=1) and pain (n=3). No retention of urine or infection occurred. Conclusion: It is very important to pay enough attention to the nursing care of puncture site and indwelling catheter sheath and to make a close observation of patient's condition in order to reduce the occurrence of complications. Rich clinical experience and careful observation after the operation can definitely reduce the occurrence of thrombolytic complications and improve the patient's living quality. (authors)

  20. Abduction of Arm Facilitates Correction of Kinked Peel-Away Sheath During Subclavian Central Line Placement.

    Science.gov (United States)

    Kim, Sunghoon

    2015-12-01

    A tunneled central line catheter placement using a subclavian vein approach can be complicated by an occurrence of peel-away sheath kink which prevents the advancement of the catheter through the sheath. The kink is created due to the angular junction of subclavian and brachiocephalic veins which meet at 90 degree angle. A technique is described which corrects the peel-away sheath kink by extending the subclavian/brachiocephalic vein angle to greater than 90 degrees by abducting the patient's arm. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na [Chonnam Univ. College of Medicine, Kwangju (Korea, Republic of)

    1999-04-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate.

  2. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    International Nuclear Information System (INIS)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na

    1999-01-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate

  3. Intentional left subclavian artery coverage during thoracic endovascular aortic repair for traumatic aortic injury.

    Science.gov (United States)

    McBride, Cameron L; Dubose, Joseph J; Miller, Charles C; Perlick, Alexa P; Charlton-Ouw, Kristofer M; Estrera, Anthony L; Safi, Hazim J; Azizzadeh, Ali

    2015-01-01

    Thoracic endovascular aortic repair (TEVAR) is widely used for treatment of traumatic aortic injury (TAI). Stent graft coverage of the left subclavian artery (LSA) may be required in up to 40% of patients. We evaluated the long-term effects of intentional LSA coverage (LSAC) on symptoms and return to normal activity in TAI patients compared with a similarly treated group whose LSA was uncovered (LSAU). Patients were identified from a prospective institutional trauma registry between September 2005 and July 2012. TAI was confirmed using computed tomography angiography. The electronic medical records, angiograms, and computed tomography angiograms were reviewed in a retrospective fashion. In-person or telephone interviews were conducted using the SF-12v2 (Quality Metrics, Lincoln, RI) to assess quality of life. An additional questionnaire was used to assess specific LSA symptoms and the ability to return to normal activities. Data were analyzed by Spearman rank correlation and multiple linear and logistic regression analysis with appropriate transformations using SAS software (SAS Institute, Cary, NC). During the study period, 82 patients (57 men; mean age 40.5 ± 20 years, mean Injury Severity Score, 34 ± 10.0) underwent TEVAR for treatment of TAI. Among them, LSAC was used in 32 (39.5%) and LSAU in 50. A group of the LSAU patients (n = 22) served as matched controls in the analysis. We found no statistically significant difference in SF-12v2 physical health scores (ρ = -0.08; P = .62) between LSAC and LSAU patients. LSAC patients had slightly better mental health scores (ρ = 0.62; P = .037) than LSAU patients. LSAC patients did not have an increased likelihood of experiencing pain (ρ = -0.0056; P = .97), numbness (ρ = -0.12; P = .45), paresthesia (ρ = -0.11; P = .48), fatigue (ρ = -0.066; P = .69), or cramping (ρ = -0.12; P = .45). We found no difference between groups in the ability to return to activities. The mean follow-up time was 3.35 years. Six LSAC

  4. Percutaneous angioplasty of carotid artery stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, G.; Freitag, J.; Koch, R.D.; Wagemann, W.

    1986-03-01

    Percutaneous transluminal angioplasty (PTA) is a well-established method to remedy stenoses and short occlusions in the femoro-popliteal region and has also proved worthwhile in dilating stenoses of pelvic, renal and coronary arteries. Following successful experiments in animals, Mathias et al. employed angioplasty to treat carotid artery stenoses in the same way. To date, successful treatment of carotid artery stenoses has been described only in isolated recent reports. For fear of embolism, angioplasty has not yet become standard practice in this region. Because of the limited number of carotid artery stenoses treated so far, the risk involved cannot be reliably assessed. It is remarkable that no embolism has been reported for the greater number of dilated stenoses of the subclavian artery. Moreover, the report by Mathias et al. indicated that for 350 angioplasties of pelvifemoral arteries 1.1% embolisms occured after artery occlusions only, while no embolism was observed after stenoses. Having gained experience of applying PTA to the treatment of vascular obstructions of extremities, we have adopted this technique in the carotid area as well.

  5. Isolated Unilateral Absent Branch Pulmonary Artery with Peripheral Pulmonary Stenosis and Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Sunil Abhishek B

    2017-09-01

    Full Text Available Isolated Unilateral Absent Pulmonary Artery (UAPA is a rare congenital anomaly. It is usually associated with congenital heart defects. A 45 year old male patient presented with complaints of fever with cough and expectoration for 15 days and retrosternal chest discomfort for the previous 2 days. ECG showed diffuse ST segment depression with T wave inversion in the inferior and lateral leads. Coronary Angiogram done through the right femoral approach revealed diffusely diseased Left Anterior Descending (LAD artery that was totally cut off at the mid segment. The Left Circumflex (LCx artery was providing blood supply to the right middle and lower lung areas. There was another collateral arising from the Left Subclavian Artery supplying the right middle and lower lung areas. The left pulmonary artery was normal, but branches supplying the middle and lower lobes of the right lung were absent and the upper lobe branch had pulmonary stenosis. UAPA is a rare clinical entity; collaterals from coronaries are extremely rare in this condition and till now there has not been any case report of unilateral absent branch pulmonary artery with peripheral stenosis of other branches, on the affected side and associated coronary artery disease.

  6. Lateral cervical puncture for cervical myelography

    International Nuclear Information System (INIS)

    Seol, Hae Young; Cha, Sang Hoon; Kim, Yoon Hwan; Suh, Won Hyuck

    1985-01-01

    Eleven cervical myelograms were performed by lateral cervical puncture using Metrizamide. So, following results were obtained: 1. Site of lateral cervical puncture; Posterior one third of bony cervical canal at C 1-2 level. 2. Advantages as compared with lumbar puncture for cervical myelograms; 1) Small amount of contrast media 2) Excellent image 3) Less position charge 4) Short time 5) Well visualization of superior margin of obstructive lesion in spinal canal 3. Cessation of lateral cervical puncture, when; 1) Pain during injection of contrast media 2) Localized collection of contrast media

  7. Lateral cervical puncture for cervical myelography

    Energy Technology Data Exchange (ETDEWEB)

    Seol, Hae Young; Cha, Sang Hoon; Kim, Yoon Hwan; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1985-12-15

    Eleven cervical myelograms were performed by lateral cervical puncture using Metrizamide. So, following results were obtained: 1. Site of lateral cervical puncture; Posterior one third of bony cervical canal at C 1-2 level. 2. Advantages as compared with lumbar puncture for cervical myelograms; 1) Small amount of contrast media 2) Excellent image 3) Less position charge 4) Short time 5) Well visualization of superior margin of obstructive lesion in spinal canal 3. Cessation of lateral cervical puncture, when; 1) Pain during injection of contrast media 2) Localized collection of contrast media.

  8. Preoperative Direct Puncture Embolization of Advanced Juvenile Nasopharyngeal Angiofibroma in Combination with Transarterial Embolization: An Analysis of 22 Consecutive Patients

    Energy Technology Data Exchange (ETDEWEB)

    Lv Mingming, E-mail: lvmingming001@163.com; Fan, Xin-dong, E-mail: fanxindong@yahoo.com.cn [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ninth People' s Hospital (China); Su Lixin, E-mail: sulixin1975@126.com [Shanghai Jiao Tong University School of Medicine, Department of Oral and Maxillofacial Surgery, Ninth People' s Hospital (China); Chen Dong, E-mail: chenjsun@public8.sta.net.cn [Shanghai Jiao Tong University School of Medicine, Department of Otolaryngology, Ninth People' s Hospital (China)

    2013-02-15

    ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20-25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Control angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.

  9. Preoperative Direct Puncture Embolization of Advanced Juvenile Nasopharyngeal Angiofibroma in Combination with Transarterial Embolization: An Analysis of 22 Consecutive Patients

    International Nuclear Information System (INIS)

    Lv Mingming; Fan, Xin-dong; Su Lixin; Chen Dong

    2013-01-01

    ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20–25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Control angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.

  10. Subclavian vein aneurysm secondary to a benign vessel wall hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Patrick [Nationwide Children' s Hospital, Section of Pediatric Interventional Radiology, Columbus, OH (United States); Spaeth, Maya [Nationwide Children' s Hospital, Section of Plastic and Reconstructive Surgery, Columbus, OH (United States); Prasad, Vinay [Nationwide Children' s Hospital, Section of Pediatric Pathology, Columbus, OH (United States); McConnell, Patrick [Nationwide Children' s Hospital, Section of Cardiothoracic Surgery, Columbus, OH (United States)

    2013-11-15

    Venous aneurysms are rare clinical entities, particularly in children, and their presentation and natural history often depend on the anatomical location and underlying etiology. We present a single case of a 12-year-old girl who presented with a palpable right supraclavicular mass. Imaging evaluation with CT, conventional venography, MRI and sonography revealed a large fusiform subclavian vein aneurysm with an unusual, mass-like fibrofatty component incorporated into the vessel wall. The girl ultimately required complete resection of the right subclavian vein with placement of a synthetic interposition graft. This case provides a radiology/pathology correlation of an entity that has not previously been described as well as an example of the utility of multiple imaging modalities to aid diagnosis and preoperative planning. (orig.)

  11. Anomalous Origin of the Left Vertebral Artery from the Aortic Arch.

    Science.gov (United States)

    Einstein, Evan H; Song, Linda H; Villela, Natalia L A; Fasani-Feldberg, Gregory B; Jacobs, Jonathan L; Kim, Dolly O; Nathawat, Akshay; Patel, Devika; Bender, Roger B; Peters, Daniel F

    2016-04-01

    Anatomic anomalies of the aortic arch have implications for clinical practice if their significance is understood. Our case study involves a cadaveric finding of the left vertebral artery originating directly from the aortic arch. Although this anatomical variation has been documented, the prevalence of this anomaly may be generally underestimated. After noting this anomaly, we analyzed 27 cases and found that four female cadavers had the left vertebral artery originating from the aortic arch rather than the left subclavian artery. With a prevalence rate of 14.8%, it would seem that this anomaly is more significant than previously thought, which could have implications for surgical practice.

  12. Retrograde pedal access with a 20-gauge intravenous cannula after failed antegrade recanalization of a tibialis anterior artery in a diabetic patient: a case report

    Directory of Open Access Journals (Sweden)

    Yucel Colkesen

    2015-08-01

    Full Text Available Retrograde tibiopedal approach is being used frequently in below-the-knee vascular interventions. In patients with diabetic foot pathology, complex anatomy often requires a retrograde technique when the distal vascular anatomy and puncture site is suitable. The dorsalis pedis and posterior tibial arteries can be punctured because of their relatively superficial position. We report a retrograde puncturing technique in patients with chronic total occlusions. After failed antegrade recanalization, puncturing and cannulation of a tiny dorsalis pedis artery with a narrow bore [20-gauge (0.8 mm] intravenous cannula is described.

  13. Surgical treatment for the subclavian steal syndrome. Surgical indication and selection of procedures by {sup 123}I-IMP-SPECT imaging and {sup 99m}Tc-HSA accumulation curve in upper extremities

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Toyohisa; Tokunaga, Hidemori; Akita, Nobuhisa; Nonaka, Masahiro [Saiseikai Chuwa Hospital, Sakurai, Nara (Japan)

    1998-03-01

    To select reasonable operative procedures in the respective patients, we have studied the cerebral blood flow, especially in the posterior circulation, by {sup 123}I-IMP-SPECT imaging, and the blood flow in the upper extremities by {sup 99m}Tc-HSA accumulation curve in 11 patients with subclavian steal syndrome. Although all patients presented distinct symptoms and signs of vertebrobasilar insufficiency, {sup 123}I-IMP-SPECT early image demonstrated no evident finding of decreased blood flow in the posterior circulation. However, in the delayed image 5 out of 11 patients revealed laterality of IMP uptake in cerebellar hemisphere. Four patients presented symptoms of the upper extremities including arm claudication, and all of them revealed {sup 99m}Tc-HSA accumulation curve indicated decreased blood flow in the affected side of arm and forearm. We performed transposition of vertebral artery to common carotid artery in 7 patients without evidence of decreased blood flow in the upper extremities by {sup 99m}Tc-HSA accumulation curve, common carotid-subclavian dacron graft bypass in 3 cases with evidence of decreased blood flow in the upper extremities, and arch aorta-common carotid dacron graft bypass for the innominate artery occlusion. When the ischemia in the anterior circulation had existed in patients with multiple cerebrovascular occlusive disease, we first corrected the anterior circulation, and then performed the revascularization for the posterior circulation mentioned above by staged operation, resulting in successful treatment of all patients. (K.H.)

  14. Suicide by severing the arterio-venous subclavian dialysis catheter.

    Science.gov (United States)

    Edirisinghe, P A S; Busuttil, A

    2006-02-01

    Haemodialysis access is an essential requirement for haemodialysis treatment in end-stage renal disease. The common forms are arteriovenous fistula (AVF) and arteriovenous grafts in ante-cubital fossa, forearm and upper thigh. Sometimes temporary or immediate access is created via a subclavian catheter or internal jugular catheter. This report is on a 79-year-old man who was suffering from chronic renal failure with a non-functional peripheral AVF; he was being dialysed through a permanent subclavian catheter and he became depressed due to continuing deterioration of his health. He used the easily accessible haemodialysis site as the method of suicide by cutting the tube that connected with the main vessel in his chest and bled to death. This highlights the requirement to assess carefully the patient's mental state in those on chronic haemodialysis, even though very few similar fatal cases have been previously reported.

  15. Subclavian Vein Stenosis/Occlusion Following Transvenous Cardiac Pacemaker and Defibrillator Implantation: Incidence, Pathophysiology and Current Management

    Directory of Open Access Journals (Sweden)

    Brian O'Leary

    2015-08-01

    Full Text Available Subclavian vein stenosis is a common, but usually asymptomatic, complication following cardiac device placement. In addition to reviewing the literature on incidence, pathogenesis and management options for this important clinical problem, we describe two cases of symptomatic subclavian vein occlusion following pacemaker/defibrillator placement and successful treatment with venoplasty and stenting.

  16. Safety and effectiveness of repeat arterial closure using the AngioSeal device in patients with hepatic malignancy.

    Science.gov (United States)

    Hieb, Robert A; Neisen, Melissa J; Hohenwalter, Eric J; Molnar, Jim A; Rilling, William S

    2008-12-01

    To retrospectively evaluate the safety and effectiveness of the use of the AngioSeal device for repeat arterial closure in patients with hepatic malignancy. A retrospective analysis of patients with hepatic malignancy who had undergone repeated arterial closure with the AngioSeal device was performed. All charts for patients undergoing transarterial chemoembolization or TheraSphere radioembolization were reviewed for the method of hemostasis and the number of arterial closures. A total of 53 patients (58.5% men, 41.5% women; mean age, 58.7 years) had repeat AngioSeal arterial puncture closure after chemoembolization or TheraSphere treatment. Percutaneous closure of the common femoral artery with the AngioSeal device was performed in accordance with the manufacturer's recommendations. The patients were examined for complications on follow-up. Effectiveness was defined by the ability to obtain satisfactory hemostasis. Safety was assessed by the absence of groin complications and by vessel patency on follow-up angiograms of the puncture site obtained at subsequent liver-directed therapy sessions. Fifty-three patients in this study group had a total of 203 common femoral artery punctures. There were a total of 161 closures with the AngioSeal device (79.3%): 58 (36%) single closures and 103 (64.0%) repeat closures. Of the 161 attempts at AngioSeal closure, there was one closure failure in the single-puncture group, yielding a success rate of 98.3%; and one closure failure in the repeat-puncture group, yielding a success rate of 99%. In these two patients, hemostasis was achieved with traditional manual compression without the need for any other device, and no complications were noted. The overall success rate of AngioSeal device closure was 98.7%. The repeat use of the AngioSeal closure device is safe and effective in patients with hepatic malignancy undergoing regional oncologic interventional procedures.

  17. Clinical significance of inter-arm pressure difference and ankle-brachial pressure index in patients with suspected coronary artery disease

    International Nuclear Information System (INIS)

    Igarashi, Yuko; Chikamori, Taishiro; Tomiyama, Hirofumi; Usui, Yasuhiro; Hida, Satoshi; Tanaka, Hirokazu; Nagao, Tadashi; Yamashina, Akira

    2007-01-01

    Although measuring blood pressure at the bilateral brachia is common in medical practice, its clinical significance in patients with suspected coronary artery disease (CAD) has not been fully clarified. The method of this study was to define the significance of inter-arm systolic blood pressure difference in patients with suspected CAD, and to assess the relationship between inter-arm pressure difference and CAD, simultaneous brachial and ankle blood pressure measurements and stress myocardial single-photon emission computed tomography (SPECT) were performed in 386 consecutive patients with suspected CAD, excluding those with previous myocardial infarction or coronary revascularization. Subclavian artery stenosis, defined as ≥15 mmHg inter-arm systolic blood pressure difference, was found in 27 patients (7%). Age (65±12 vs 65±11 years), male sex (21/27 vs 244/359), prevalence of hypertension (63% vs 56%), hypercholesterolemia (63% vs 62%), diabetes mellitus (33% vs 38%), cigarette smoking (44% vs 41%) and family history of CAD (15% vs 12%) were similar between patients with subclavian artery stenosis and those without. The incidence of decreased ankle-brachial pressure index (ABI) was higher (37% vs 12%, p=0.001), and percentage ischemic myocardium as assessed by SPECT was greater (9.0±8.5% vs 5.6±6.6%, p=0.05) in patients with subclavian artery stenosis than in those without. Furthermore, significant correlations were observed between inter-arm pressure difference and percentage ischemic myocardium (r=0.13; p=0.01), and ABI (r=-0.26, p<0.0001). Among 386 patients, 283 underwent coronary angiography, and 63% of those who had inter-arm blood pressure difference had CAD. Furthermore, 83% of those CAD patients had multi-vessel CAD, which is regarded as a high-risk subset for subsequent cardiac events. Inter-arm pressure difference is often found in patients with suspected CAD, and is associated with significant CAD and peripheral artery disease. Thus, inter

  18. Retrograde Embolization of the Left Vertebral Artery in a Type II Endoleak After Endovascular Treatment of Aortic Thoracic Rupture: Technical Note

    International Nuclear Information System (INIS)

    Rabellino, Martin; Garcia Nielsen, L.; Baldi, S.; Zander, T.; Arnaiz, L.; Llorens, R.; Zerolo, I.; Maynar, M.

    2009-01-01

    Endoleak is a frequent complication after endovascular repair of aortic rupture. We describe the case of a female patient with traumatic aortic injury, treated with endograft, who developed a type II endoleak through the left subclavian and vertebral arteries. Both arteries originated independently from the aortic arch, and were managed with coil embolization of each vessel. We also report our experience with treating the left vertebral artery by placing a microcatheter through the right vertebral one.

  19. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    International Nuclear Information System (INIS)

    Tokue, Hiroyuki; Tokue, Azusa; Tsushima, Yoshito

    2012-01-01

    We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP) using routine 64 multidetector-row computed tomography (MDCT) data in order to plan for the implantation of an intra-arterial hepatic port system. A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward). The median branching angle was (median ± standard deviation) 135 ± 23 (range, 51–174) degrees. The branching was upward in 77 patients (7%) and downward in 1,027 patients (93%). The branching was downward with an angle of 120 to150 degrees in most patients (n = 613). The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%). A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery

  20. Incidence and predictors of post-catheterization femoral artery pseudoaneurysms

    Directory of Open Access Journals (Sweden)

    Hussein Heshmat Kassem

    2013-09-01

    Conclusion: Femoral artery pseudoaneurysms are not uncommon. Female gender, obesity, hypertension, the use of antiplatelet and/or anticoagulant therapy and faulty puncture techniques are independent risk factors for FAPs.

  1. Morphologic features of puncture sites after exoseal vascular closure device implantation: Changes on follow-up computed tomography

    International Nuclear Information System (INIS)

    Ryu, Hwa Seong; Jang, Joo Yeon; Kim, Tae Un; Lee, Jun Woo; Park, Jung Hwan; Choo, Ki Seok; Cho, Mong; Yoon, Ki Tae; Hong, Young Ki; Jeon, Ung Bae

    2017-01-01

    The study aimed to evaluate the morphologic changes in transarterial chemoembolization (TACE) puncture sites implanted with an ExoSeal vascular closure device (VCD) using follow-up computed tomography (CT). 16 patients who used ExoSeal VCD after TACE were enrolled. Using CT images, the diameters and anterior wall thicknesses of the puncture sites in the common femoral artery (CFA) were compared with those of the contralateral CFA before TACE, at 1 month after every TACE session, and at the final follow-up period. The rates of complications were also evaluated. There were no puncture- or VCD-related complications. Follow-up CT images of the CFA's of patients who used ExoSeal VCDs showed eccentric vascular wall thickening with soft-tissue densities considered to be hemostatic plugs. Final follow-up CT images (mean, 616 days; range, 95–1106 days) revealed partial or complete resorption of the hemostatic plugs. The CFA puncture site diameters did not differ statistically from those of the contralateral CFA on the final follow-up CT (p > 0.05), regardless of the number of VCDs used. Follow-up CT images of patients who used ExoSeal VCDs showed no significant vascular stenosis or significant vessel wall thickening

  2. Morphologic features of puncture sites after exoseal vascular closure device implantation: Changes on follow-up computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Hwa Seong; Jang, Joo Yeon; Kim, Tae Un; Lee, Jun Woo; Park, Jung Hwan; Choo, Ki Seok; Cho, Mong; Yoon, Ki Tae; Hong, Young Ki; Jeon, Ung Bae [Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2017-05-15

    The study aimed to evaluate the morphologic changes in transarterial chemoembolization (TACE) puncture sites implanted with an ExoSeal vascular closure device (VCD) using follow-up computed tomography (CT). 16 patients who used ExoSeal VCD after TACE were enrolled. Using CT images, the diameters and anterior wall thicknesses of the puncture sites in the common femoral artery (CFA) were compared with those of the contralateral CFA before TACE, at 1 month after every TACE session, and at the final follow-up period. The rates of complications were also evaluated. There were no puncture- or VCD-related complications. Follow-up CT images of the CFA's of patients who used ExoSeal VCDs showed eccentric vascular wall thickening with soft-tissue densities considered to be hemostatic plugs. Final follow-up CT images (mean, 616 days; range, 95–1106 days) revealed partial or complete resorption of the hemostatic plugs. The CFA puncture site diameters did not differ statistically from those of the contralateral CFA on the final follow-up CT (p > 0.05), regardless of the number of VCDs used. Follow-up CT images of patients who used ExoSeal VCDs showed no significant vascular stenosis or significant vessel wall thickening.

  3. [Digital necrosis in a patient with anorexia nervosa. Association of vasculopathy and radial artery injury].

    Science.gov (United States)

    Launay, D; Queyrel, V; Hatron, P Y; Michon-Pasturel, U; Hachulla, E; Devulder, B

    2000-11-13

    Patients with anorexia nervosa can develop distal vasculopathy sometimes leading to severe Raynaud's phenomenon or acrocyanosis. We report a cas of anorexia nervosa-related vasculopathy associated with iatrogenic injury to the radial artery that led to digital necrosis. An 18-year-old woman, with a history of severe anorexia nervosa of 5 years duration and who acknowledged regular use of tobacco and cannabis, was hospitalized for necrosis of the left index and thumb that had occurred shortly after left radial artery puncture for blood gas analysis. Acrocyanosis of the 4 limbs had been present since the onset of anorexia nervosa. Arteriography of the upper limbs showed major spasm of the left radial and cubital arteries and thromboses in the left interdigital arteries of the left index and thumb. The distal portions of the arteries were then on the left and on the right. The nectrotic lesions healed after intravenous administration of ilomedine and interruption of tobacco and cannabis. Acrocyanosis of the four limbs persisted. We report a case of digital necrosis occurring after arterial puncture for blood gas analysis in a patient with a vascular bed weakened by tobacco and cannabis intoxication but also by anorexia nervosa-related vasculopathy. This observation underlines the potentially dangerous nature of invasive intravascular procedures in this context. Indications for vessel puncture must be assessed with prudence.

  4. Arterial supply, venous drainage and collateral circulation in the nose of the anaesthetized dog.

    Science.gov (United States)

    Lung, M A; Wang, J C

    1987-01-01

    1. In pentobarbitone-anaesthetized dogs, nasal blood flows were measured with electromagnetic flow sensors. 2. The terminal internal maxillary artery was found to supply 22 +/- 2.2 ml min-1 (one side) to the nasal mucosa via the sphenopalatine and major palatine branches; the artery was found to receive multiple supply routes from common carotid, vertebral and subclavian arteries. 3. Nasal mucosa was found to receive collateral flow from contralateral terminal internal maxillary artery (about 5 to 10% of normal flow) and branches of subclavian arteries (about 36% of normal flow). 4. Nasal mucosa was found to have two venous systems: the low-flow (12 +/- 1.0 ml min-1; both sides) and low-pressure (7 +/- 0.6 mmHg) sphenopalatine veins draining the posterior nasal cavity and the high-flow (30 +/- 1.4 ml min-1; both sides) and high-pressure (17 +/- 1.0 mmHg) dorsal nasal veins draining the anterior nasal cavity. 5. PO2 of nasal venous blood was found to range from 62 +/- 2.9 mmHg to 65 +/- 3.4 mmHg. During nitrogen challenge to the nose, the sphenopalatine venous PO2 dropped to 35 +/- 3.0 mmHg while the dorsal nasal venous PO2 remained unchanged, suggesting that the sphenopalatine veins were responsible for draining capillary flow and dorsal nasal veins arteriovenous anastomotic flow as well. 6. Microscopic examination of the vascular casts confirmed that arteriovenous anastomoses were located only in the anterior nasal cavity. Images Fig. 5 Plate 1 Plate 2 PMID:3443958

  5. Popliteal versus tibial retrograde access for subintimal arterial flossing with antegrade-retrograde intervention (SAFARI) technique.

    Science.gov (United States)

    Hua, W R; Yi, M Q; Min, T L; Feng, S N; Xuan, L Z; Xing, J

    2013-08-01

    This study aimed to ascertain differences in benefit and effectiveness of popliteal versus tibial retrograde access in subintimal arterial flossing with the antegrade-retrograde intervention (SAFARI) technique. This was a retrospective study of SAFARI-assisted stenting for long chronic total occlusion (CTO) of TASC C and D superficial femoral lesions. 38 cases had superficial femoral artery lesions (23 TASC C and 15 TASC D). All 38 cases underwent SAFARI-assisted stenting. The ipsilateral popliteal artery was retrogradely punctured in 17 patients. A distal posterior tibial (PT) or dorsalis pedis (DP) artery was retrogradely punctured in 21 patients, and 16 of them were punctured after open surgical exposure. SAFARI technical success was achieved in all cases. There was no significant difference in 1-year primary patency (75% vs. 78.9%, p = .86), secondary patency (81.2% vs. 84.2%, p = .91) and access complications (p = 1.00) between popliteal and tibial retrograde access. There was statistical difference in operation time between popliteal (140.1 ± 28.4 min) and tibial retrograde access with PT/DP punctures after surgical vessel exposure (120.4 ± 23.0 min, p = .04). The SAFARI technique is a safe and feasible option for patients with infrainguinal CTO (TASC II C and D). The PT or DP as the retrograde access after surgical vessel exposure is a good choice when using the SAFARI technique. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Percutaneous microcrystalline chitosan application for sealing arterial puncture sites

    NARCIS (Netherlands)

    Hoekstra, A; Struszczyk, H; Kivekas, O

    Arterial catheterization is one of the most frequently performed inpatient diagnostic and therapeutic procedures in the development countries. Complications may occur after any catheterization from inadequate hemostasis, particularly in the setting of aggressive anticoagulation. This study suggests

  7. Selective intra-arterial digital subtraction angiography (IADSA) in cerebrovascular disease

    International Nuclear Information System (INIS)

    Uchino, Akira; Satoh, Yoshiyuki; Ohno, Masato

    1987-01-01

    Selective right transbrachial intra-arterial digital subtraction angiography (transbrachial selective IADSA) was successfully performed for 24 of 26 patients with known or suspected cerebrovascular disease, four of whom were outpatients. Catheterization failed in two elderly hypertensive men because of tortuosity of their brachial arteries, and in one woman whose aberrant right subclavian artery (SCA) prevented bilateral common carotid arterial (CCA) catheterizations. No complications occurred. One-hundred and ten ''excellent'' images were obtained by means of 118 injections for the 24 patients. Iopamidol, the contrast medium, was diluted to 50 % concentration with saline, then warmed to 37 deg C. Nearly all the injections of both CCAs and right vertebral arteries (VAs) were completed using 10 ml injections and a 5 ml/sec flow rate. The mean examination time for the three-vessel study was 29.4 minutes. Transbrachial selective IADSA thus proved to be a safe, useful, and relatively easy means of diagnosing cerebrovascular disease. (author)

  8. Unilateral transpedicular percutaneous vertebroplasty using puncture simulation

    International Nuclear Information System (INIS)

    Kobayashi, Ken; Takizawa, Kenji; Koyama, Masamichi; Yoshimatsu, Misako; Sakaino, Shinjiro; Nakajima, Yasuo

    2006-01-01

    The aim of this study was to improve the accuracy of puncture to the median vertebral body using the unilateral transpedicular approach on percutaneous vertebroplasty (PVP). We have developed and evaluated a simple puncture simulation method based on the puncture angle determined by preoperative computed tomography (CT). Two groups were evaluated. The first (group A) comprised 23 patients (34 vertebral bodies) who had undergone PYP without preoperative puncture simulation before May 2004, and the second group (group B) comprised 24 patients (39 vertebral bodies) who had undergone preoperative puncture simulation and PVP after May 2004. CT in the prone position was performed, and the puncture angle on CT (PAC) via the vertebral arch pedicle targeting the anterior one-third median site of the vertebral body was determined. Puncture was performed by targeting the isocenter established on a fluoroscopic monitor based on the PAC. Determinations were made of the success rate (SR) of the median puncture of the vertebral body, the effect of treatment using the visual analogue score, and the overall procedural time between groups A and B. The SR was 56% (19/34 vertebral bodies) in group A, and 97% (37/38 vertebral bodies), including only one vertebral body in which it was difficult to perform the unilateral approach on CT images, in group B, with the difference being significant by Student's t-test (P<0.001). Among patients with available follow-up data, the unipedicular and bipedicular approaches achieved adequate pain relief with mean decreases in pain severity of 5.1±2.6 and 5.9±2.8 respectively. No significant differences in the treatment effect between the two groups was observed (P=0.811). The overall procedure time per puncture was shorten for the simulation group (36.0 min) than for group A (73.1 min), as shown by regression analysis. The preoperative PAC determination for PVP under fluoroscopy increased the completion rate of PVP by the unilateral transpedicular

  9. Numerical and experimental analysis of the transitional flow across a real stenosis.

    Science.gov (United States)

    Agujetas, R; Ferrera, C; Marcos, A C; Alejo, J P; Montanero, J M

    2017-08-01

    In this paper, we present a numerical study of the pulsatile transitional flow crossing a severe real stenosis located right in front of the bifurcation between the right subclavian and right common carotid arteries. The simulation allows one to determine relevant features of this subject-specific flow, such as the pressure waves in the right subclavian and right common carotid arteries. We explain the subclavian steal syndrome suffered by the patient in terms of the drastic pressure drop in the right subclavian artery. This pressure drop is caused by both the diverging part of the analyzed stenosis and the reverse flow in the bifurcation induced by another stenosis in the right internal carotid artery.

  10. Dysphagia lusoria: clinical aspects, manometric findings, diagnosis, and therapy

    NARCIS (Netherlands)

    Janssen, M.; Baggen, M. G.; Veen, H. F.; Smout, A. J.; Bekkers, J. A.; Jonkman, J. G.; Ouwendijk, R. J.

    2000-01-01

    OBJECTIVE: The lusorian artery is a rare anomaly of the right subclavian artery. This artery arises from the aortic arch distal of the left subclavian artery, crossing the midline behind the esophagus. Normally this anomaly causes no symptoms. Sometimes dysphagia first appears above the age of 40

  11. Endovascular repair of an innominate artery pseudoaneurysm using the Valiant Mona LSA branched graft device

    Directory of Open Access Journals (Sweden)

    Josh A. Sibille, MD

    2017-03-01

    Full Text Available A 60-year-old woman involved in a motor vehicle collision presented with a traumatic pseudoaneurysm of the innominate artery origin in addition to multiple concomitant injuries. She was classified as a high-risk candidate for open repair. An experimental thoracic branched graft device was used for coverage of the injury with the addition of a right carotid-to-left carotid-to-left subclavian artery bypass. Follow-up imaging showed resolution of the pseudoaneurysm and patency of her bypass grafts. This is the first described use of the Mona LSA Branch Thoracic Stent Graft System (Medtronic, Minneapolis, Minn in the innominate artery.

  12. Changing the needle for lumbar punctures

    DEFF Research Database (Denmark)

    Engedal, Thorbjørn Søndergaard; Ording, H.; Vilholm, O. J.

    2015-01-01

    Objective: Post-dural puncture headache (PDPH) is a common complication of diagnostic lumbar punctures. Both a non-cutting needle design and the use of smaller size needles have been shown to greatly reduce the risk of PDPH. Nevertheless, larger cutting needles are still widely used. This study d...

  13. Treatment of lower extremity arterial occlusive through retrograde access

    International Nuclear Information System (INIS)

    Liu Xueqiang; Guo Pingfan; Zhang Jinchi; Cai Fanggang

    2012-01-01

    Objective: To explore the clinical significance of retrograde access for the interventional treatment of lower extremity arterial occlusive diseases when the occluded segment of lower extremity artery could not be reached through antegrade access. Methods: Twenty-seven cases (male 17, female 10; age range 32-89 years) were retrospectively investigated, including 18 with lower limb arteriosclerosis obliterans, 7 with diabetic foot and 2 with thromboangiitis obliterans. According to the Fontaine staging, 6 cases were classified as Fontaine Ⅱ, 11 were classified as Fontaine Ⅲ and 10 were classified as Fontaine Ⅳ. All cases underwent endovascular operation through antegrade access first with an attempt to cross the occlusive segment, but in vain. So retrograde access was tried via puncture of pedis dorsalis or posterior tibial artery or exposure of lateral branches of posterior tibial artery, peroneal artery or dorsal artery by open surgery,which followed by Percutaneous transluminal angiography and (or) stenting. Results: The operation through retrograde access was successful in all cases with obvious improvement of ischemic symptoms. Hematoma at the puncture site occurred in 3 patients, and paresthesia of toes occurred in 1 after dorsalis pedis arteriotomy. No severe perioperative complication occurred. The average ankle brachial index increased from 0.37 ± 0.11 preoperatively to 0.85 ± 0.12 postoperatively. Conclusions: Retrograde access could be used as an alternative strategy in lower extremity arterial occlusive diseases when the occluded segment could not reach through antegrade access. (authors)

  14. Endo-aneurysmorrhaphy of a giant aneurysm of the subclavian vein

    Directory of Open Access Journals (Sweden)

    Ahmed Afifi

    2012-07-01

    Full Text Available Venous aneurysms are relatively rare anomalies which can affect different parts of the vascular system. Diagnosis and management of this condition could pose important problems. We here report a giant false aneurysm of the subclavian vein with emphasis on the thought process that determined the management strategy.

  15. Subintimal Recanalization of Long Superficial Femoral Artery Occlusions Through the Retrograde Popliteal Approach

    International Nuclear Information System (INIS)

    Yilmaz, Saim; Sindel, Timur; Ceken, Kagan; Alimoglu, Emel; Lueleci, Ersin

    2001-01-01

    Purpose: To investigate the value of the retrograde popliteal artery approach for the percutaneous intentional extraluminal recanalization (PIER) of long superficial femoral artery (SFA) occlusions.Methods: During a period of 17 months, PIER through ultrasound-guided retrograde popliteal artery puncture was performed for 39 long SFA occlusions in 37 patients. In six patients, six additional iliac artery stenoses were also treated via the popliteal approach.Results: The procedure was technically successful in 32 (82%) of 39 SFA occlusions; in 29, lesions were treated with balloon angioplasty alone, and in three, stents were also used. Cumulative patency rate was 66% at 6 months, 62% at 1 year, and 59% at 18 months. Additional iliac artery stenoses were successfully treated in the same session. Complications included two minor hematomas and two SFA ruptures, which required no treatment.Conclusion: PIER through retrograde popliteal puncture is a safe and effective method in the treatment of long femoropopliteal occlusions, with a high technical success, low complication rate and a reasonable short-term patency rate. The technique offers an alternative in cases where standard PIER is unsuccessful or contraindicated

  16. Coexistence of Single Coronary Artery Anomaly and Aortic Arch Anomaly

    Directory of Open Access Journals (Sweden)

    Yilmaz Omur Otlu

    2014-03-01

    Full Text Available A 74-year-old male patient was admitted to our hospital for evaluation of recent onset atypical chest pain. His medical history included hypertension, dislipidemia and smoking. Physical examination was unremarkable. The resting electrocardiogram was demonstrated biphasic T waves on lateral derivations. Transthoracic echocardiography showed normal left and right ventricular dimensions and functions. Coronary angiography was planned for the patient. First, right transradial approach tried; but guidewire could not be advanced to ascendig aorta. Coronary angiography was performed through the right femoral artery. Multiple attempts to cannulate the left coronary ostium were unsuccessful. The right coronary artery cannulated from its normal ostium in the right sinus of Valsalva. After a very short common main stem, the artery divided into a right coronary artery, and separate left anterior descending artery and circumflex artery (Figure A. The coronary arteries were normal without any significant stenosis and any extrinsic compression. An aortic root injection confirmed the absence of left coronary ostium. Also, a retroesophageal right subclavian artery originating from the left aortic arch (arteria lusoria was detected as the last branch of aortic arch on contrast enhanced computerized tomography (Figure B-C. The patient discharged with medical teraphy.

  17. New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

    International Nuclear Information System (INIS)

    Juszkat, Robert; Kulesza, Jerzy; Zarzecka, Anna; Jemielity, Marek; Staniszewski, Ryszard; Majewski, Wacław

    2011-01-01

    To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a—the segment distally the origin of the left CCA, halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.

  18. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    Directory of Open Access Journals (Sweden)

    Tokue Hiroyuki

    2012-12-01

    Full Text Available Abstract Background We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP using routine 64 multidetector-row computed tomography (MDCT data in order to plan for the implantation of an intra-arterial hepatic port system. Methods A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward. Results The median branching angle was (median ± standard deviation 135 ± 23 (range, 51–174 degrees. The branching was upward in 77 patients (7% and downward in 1,027 patients (93%. The branching was downward with an angle of 120 to150 degrees in most patients (n = 613. The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%. A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. Conclusions The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery.

  19. Subclavian vein pacing and venous pressure waveform measurement for phrenic nerve monitoring during cryoballoon ablation of atrial fibrillation.

    Science.gov (United States)

    Ghosh, Justin; Singarayar, Suresh; Kabunga, Peter; McGuire, Mark A

    2015-06-01

    The phrenic nerves may be damaged during catheter ablation of atrial fibrillation. Phrenic nerve function is routinely monitored during ablation by stimulating the right phrenic nerve from a site in the superior vena cava (SVC) and manually assessing the strength of diaphragmatic contraction. However the optimal stimulation site, method of assessing diaphragmatic contraction, and techniques for monitoring the left phrenic nerve have not been established. We assessed novel techniques to monitor phrenic nerve function during cryoablation procedures. Pacing threshold and stability of phrenic nerve capture were assessed when pacing from the SVC, left and right subclavian veins. Femoral venous pressure waveforms were used to monitor the strength of diaphragmatic contraction. Stable capture of the left phrenic nerve by stimulation in the left subclavian vein was achieved in 96 of 100 patients, with a median capture threshold of 2.5 mA [inter-quartile range (IQR) 1.4-5.0 mA]. Stimulation of the right phrenic nerve from the subclavian vein was superior to stimulation from the SVC with lower pacing thresholds (1.8 mA IQR 1.4-3.3 vs. 6.0 mA IQR 3.4-8.0, P phrenic nerve palsy. The left phrenic nerve can be stimulated from the left subclavian vein. The subclavian veins are the optimal sites for phrenic nerve stimulation. Monitoring the femoral venous pressure waveform is a novel technique for detecting impending phrenic nerve damage. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  20. Digital arteriography of kidney arteries by intraveinous route. Simplified technique

    International Nuclear Information System (INIS)

    Guisgand, M.; Dardenne, A.N.

    1989-01-01

    Of the 1,000 patients addressed to us for intravenous digital angiography (IVDA) of the renal arteries for arterial hypertension, for control of the artery of a transplanted kidney or for preoperative check-up prior to transplantation of a kidney, 738 were examined by a simplified technique. Compared to the standard practice this method simply consists of a manual injection of a standard ionic contrast medium via an antecubital vein punctured with a large catheter needle (caliber 14 G), without preparatory injection of an intestinal antispasmodic. This method has produced a satisfactory arterial opacification in 96 % of the cases. The advantages and disadvantages of the technique are discussed. Of the 262 remaining patients, 250 were also examined by the peripheral venous mode, but the technique had to be modified in at least one of its aspects for one reason or another. Only 12 patients were not examined by the peripheral venous mode (7 puncture failures, 4 permanent venous accesses already installed). The IVDA simplified technique appears to be reliable for detecting reno-vascular arterial hyper-tension and, with certain limitations, for the control of kidney grafts. With regard to the preoperative check-up before kidney transplantation, IVDA still does not seem a suitable replacement for the traditional method of angiography [fr

  1. Internal Jugular and Subclavian Vein Thrombosis in a Case of Ovarian Cancer

    Directory of Open Access Journals (Sweden)

    Hiroto Moriwaki

    2017-01-01

    Full Text Available Central venous catheter insertion and cancer represent some of the important predisposing factors for deep venous thrombosis (DVT. DVT usually develops in the lower extremities, and venous thrombosis of the upper extremities is uncommon. Early diagnosis and treatment of deep venous thrombosis are of importance, because it is a precursor of complications such as pulmonary embolism and postthrombotic syndrome. A 47-year-old woman visited our department with painful swelling on the left side of her neck. Initial examination revealed swelling of the region extending from the left neck to the shoulder without any redness of the overlying skin. Laboratory tests showed a white blood cell count of 5,800/mm3 and an elevated serum C-reactive protein of 4.51 mg/dL. Computed tomography (CT of the neck revealed a vascular filling defect in the left internal jugular vein to left subclavian vein region, with the venous lumina completely occluded with dense soft tissue. On the basis of the findings, we made the diagnosis of thrombosis of the left internal jugular and left subclavian veins. The patient was begun on treatment with oral rivaroxaban, but the left shoulder pain worsened. She was then admitted to the hospital and treated by balloon thrombectomy and thrombolytic therapy, which led to improvement of the left subclavian venous occlusion. Histopathologic examination of the removed thrombus revealed adenocarcinoma cells, indicating hematogenous dissemination of malignant cells.

  2. ST-segment elevation and ventricular fibrillation shortly after transseptal puncture for left atrial catheter ablation

    Directory of Open Access Journals (Sweden)

    Daisuke Ishigaki, MD

    2013-10-01

    Full Text Available A 47-year-old man with drug-resistant paroxysmal atrial fibrillation underwent left atrial (LA catheter ablation. After sheaths were inserted into the LA using the Brockenbrough method, he complained of angina and developed ST-segment elevation in the II, III, aVF, V5, and V6 leads. Ventricular fibrillation (VF occurred followed by ventricular tachycardia. The VF was successfully treated with direct current shock. Coronary angiography with isosorbide dinitrate showed neither spasm nor embolism in the coronary artery. The chest pain disappeared after 6 min with resolution of the ST-segment elevation. A summarized review of ST-segment elevation associated with transseptal puncture disclosed that ST-segment elevation is often found in inferior leads (87.5%, while concomitant bradyarrhythmia has been reported in 43.8% of patients. Our patient is the first recorded case with potentially lethal tachyarrhythmia. Although ST-segment elevation and VF is a rare complication associated with transseptal puncture, awareness of this complication is important.

  3. Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

    International Nuclear Information System (INIS)

    Hirata, Masaaki; Watanabe, Ryouhei; Koyano, Yasuhiro; Sugata, Shigenori; Takeda, Yukie; Nakamura, Seiji; Akamune, Akihisa; Tsuda, Takaharu; Mochizuki, Teruhito

    2017-01-01

    PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

  4. Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Masaaki, E-mail: masaaki314@gmail.com [Matsuyama Shimin Hospital, Department of Radiology (Japan); Watanabe, Ryouhei; Koyano, Yasuhiro [Matsuyama Shimin Hospital, Department of Surgery (Japan); Sugata, Shigenori; Takeda, Yukie [Ehime Prefectural Imabari Hospital, Department of Radiology (Japan); Nakamura, Seiji; Akamune, Akihisa [Matsuyama Shimin Hospital, Department of Radiology (Japan); Tsuda, Takaharu; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology (Japan)

    2017-04-15

    PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

  5. Applied anatomy of thyroid arteries for interventional embolization of Graves' disease

    International Nuclear Information System (INIS)

    Ding Zhongxiang; Zhao Wei; Hou Jialin; Xiang Shutian; Li Liyuan; Zou Zhirong; Li Xingguo; Song Dianping; Yuan Jianhua

    2007-01-01

    Objective: To explore the anatomy and imaging manifestations of thyroid arteries for improving the efficiency and lowering the complication in interventional embolization of Graves' disease. Methods: Thyroid arteries were investigated, including 16 adult cadavers (Cadaver group), 8 non-thyropathic patients (Normal group)and 17 Graves patients (Graves group). The inner diameters of the trunk and supplying branches of thyroid artery, the angles between the origination of branches and the beginning of the trunk, and the angles between the trunk of thyroid artery and carotid or subclavian artery were measured. In addition, data of the three groups were statistically analyzed. Results: Many non-thyroid arterial branches arose from thyroid artery, with no statistical difference in their indexes between Cadaver group and Normal group. The thyroid arteries showed much longer, obviously wider in diameter, and larger angles between the trunk of thyroid artery and carotid artery in Graves group than those of Cadaver group and Normal group; outcoming with significant statistical differences; and furthermore, with increase of interglandular branches and dangerous internal and external anastomoses. Conclusions: The specific thyroid arterial changes of Graves' disease are helpful for the interventional embolization. Non-thyroid branches and dangerous anastomoses should not be embolized as far as possible, for decreasing the complications of the interventional procedure for Graves' disease. (authors)

  6. Optimizing Residents' Performance of Lumbar Puncture

    DEFF Research Database (Denmark)

    Henriksen, Mikael Johannes Vuokko; Wienecke, Troels; Thagesen, Helle

    2018-01-01

    Background: Lumbar puncture is often associated with uncertainty and limited experience on the part of residents; therefore, preparatory interventions can be essential. There is growing interest in the potential benefit of videos over written text. However, little attention has been given...... to whether the design of the videos impacts on subsequent performance. Objective: To investigate the effect of different preparatory interventions on learner performance and self-confidence regarding lumbar puncture (LP). Design: Randomized controlled trial in which participants were randomly assigned to one...... of three interventions as preparation for performing lumbar puncture: 1) goal- and learner-centered video (GLV) presenting procedure-specific process goals and learner-centered information; 2) traditional video (TV) providing expert-driven content, but no process goals; and 3) written text (WT...

  7. Recanalization of superficial femoral artery by retrograde approach via popliteal artery

    International Nuclear Information System (INIS)

    Kim, Jae Kyu; Kim, Hyung Kil; Yun, Ung; Seo, Jeong Jin; Kang, Heoung Keun

    1995-01-01

    To recanalize the occlusive lesion of superficial femoral artery at origin site by retrograde approach via popliteal artery. 15 patients, who were poor surgical candidates due to coronary artery disease and who had severe occlusive lesion of superficial femoral artery close to its origin with good distal runoffs to popliteal artery, were selected. Patients were all men and range of age were from 53 years to 66 years (mean age: 63 years). Range of lesion length were from 15 cm to 30 cm (mean length: 22.4 cm). Localization of popliteal artery was done with Doppler stethoscope or 'road-map' DSA. The method of recanalization were transluminal endarterectomy catheter (TEC), TEC and angioplasty, thrombolysoangioplasty (TLA). Retrograde puncture of popliteal artery was done in 15 patients successfully. TEC and PTA was performed in 9 patients, TEC only in 2 patients, and TLA and PTA in 2 patients. During the follow-up period of 5 months to 2 years reocclusion did not occur in 10 patients except for 1 patient with poor cardiac output in whom it occurred 1 day later. Remained 4 patients were lost in follow up. Any neurologic or vascular complication did not occur. Retrograde approach of superficial femoral artery via popliteal artery in patients with difficult vascular intervention by common method provides a useful, alternative recanalization method

  8. Recanalization of superficial femoral artery by retrograde approach via popliteal artery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Kyu; Kim, Hyung Kil; Yun, Ung; Seo, Jeong Jin; Kang, Heoung Keun [Chonnam University Medical School, Kwangju (Korea, Republic of)

    1995-09-15

    To recanalize the occlusive lesion of superficial femoral artery at origin site by retrograde approach via popliteal artery. 15 patients, who were poor surgical candidates due to coronary artery disease and who had severe occlusive lesion of superficial femoral artery close to its origin with good distal runoffs to popliteal artery, were selected. Patients were all men and range of age were from 53 years to 66 years (mean age: 63 years). Range of lesion length were from 15 cm to 30 cm (mean length: 22.4 cm). Localization of popliteal artery was done with Doppler stethoscope or 'road-map' DSA. The method of recanalization were transluminal endarterectomy catheter (TEC), TEC and angioplasty, thrombolysoangioplasty (TLA). Retrograde puncture of popliteal artery was done in 15 patients successfully. TEC and PTA was performed in 9 patients, TEC only in 2 patients, and TLA and PTA in 2 patients. During the follow-up period of 5 months to 2 years reocclusion did not occur in 10 patients except for 1 patient with poor cardiac output in whom it occurred 1 day later. Remained 4 patients were lost in follow up. Any neurologic or vascular complication did not occur. Retrograde approach of superficial femoral artery via popliteal artery in patients with difficult vascular intervention by common method provides a useful, alternative recanalization method.

  9. Ramescência do arco aórtico no gambá-de-orelha-branca (Didelphis albiventris

    Directory of Open Access Journals (Sweden)

    Bruno César Schimming

    2016-09-01

    Full Text Available Knowledge of the aortic arch main and collateral branches is important because these arteries supply vital organs found in the head, neck, thoracic cavity and forelimbs of domestic and wild animals. This study aimed to contribute to the anatomical knowledge in opossums and collaborate with veterinary medical and surgical clinics. Thus, the anatomy of aortic arch was described in eighteen opossums. The results indicated that the aortic arch gives off the brachiocephalic trunk and the left subclavian artery in all animals studied. The branching pattern of the aortic arch is similar to that reported in the guinea pig, chinchilla, paca, raccoon, nutria, red squirrel, and ocelot. The brachiocephalic trunk showed as collateral branches, the right subclavian artery and the bicarotid trunk, that originated in the right and left common carotid arteries (77.7%. Bicarotid trunk was absent in four animals (22.2%. The right and left subclavian arteries originated in the vertebral artery, costocervical trunk, internal thoracic artery, and superficial cervical artery. Collateral branches of the subclavian artery showed similarities to that observed in other wild animals such as paca, ocelot and rock cavy.

  10. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    International Nuclear Information System (INIS)

    Akahane, Akio; Sone, Miyuki; Ehara, Shigeru; Kato, Kenichi; Tanaka, Ryoichi; Nakasato, Tatsuhiko

    2011-01-01

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access―the subclavian vein and arm vein―in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1–891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

  11. Emergency medical technician-performed point-of-care blood analysis using the capillary blood obtained from skin puncture.

    Science.gov (United States)

    Kim, Changsun; Kim, Hansol

    2017-12-09

    Comparing a point-of-care (POC) test using the capillary blood obtained from skin puncture with conventional laboratory tests. In this study, which was conducted at the emergency department of a tertiary care hospital in April-July 2017, 232 patients were enrolled, and three types of blood samples (capillary blood from skin puncture, arterial and venous blood from blood vessel puncture) were simultaneously collected. Each blood sample was analyzed using a POC analyzer (epoc® system, USA), an arterial blood gas analyzer (pHOx®Ultra, Nova biomedical, USA) and venous blood analyzers (AU5800, DxH2401, Beckman Coulter, USA). Twelve parameters were compared between the epoc and reference analyzers, with an equivalence test, Bland-Altman plot analysis and linear regression employed to show the agreement or correlation between the two methods. The pH, HCO 3 , Ca 2+ , Na + , K + , Cl - , glucose, Hb and Hct measured by the epoc were equivalent to the reference values (95% confidence interval of mean difference within the range of the agreement target) with clinically inconsequential mean differences and narrow limits of agreement. All of them, except pH, had clinically acceptable agreements between the two methods (results within target value ≥80%). Of the remaining three parameters (pCO 2, pO 2 and lactate), the epoc pCO 2 and lactate values were highly correlated with the reference device values, whereas pO 2 was not. (pCO 2 : R 2 =0.824, y=-1.411+0.877·x; lactate: R 2 =0.902, y=-0.544+0.966·x; pO 2 : R 2 =0.037, y=61.6+0.431·x). Most parameters, except only pO 2 , measured by the epoc were equivalent to or correlated with those from the reference method. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Endovascular technique using a snare and suture for retrieving a migrated peripherally inserted central catheter in the left pulmonary artery

    Science.gov (United States)

    Teragawa, Hiroki; Sueda, Takashi; Fujii, Yuichi; Takemoto, Hiroaki; Toyota, Yasushi; Nomura, Shuichi; Nakagawa, Keigo

    2013-01-01

    We report a successful endovascular technique using a snare with a suture for retrieving a migrated broken peripherally inserted central catheter (PICC) in a chemotherapy patient. A 62-year-old male received monthly chemotherapy through a central venous port implanted into his right subclavian area. The patient completed chemotherapy without complications 1 mo ago; however, he experienced pain in the right subclavian area during his last chemotherapy session. Computed tomography on that day showed migration of a broken PICC in his left pulmonary artery, for which the patient was admitted to our hospital. We attempted to retrieve the ectopic PICC through the right jugular vein using a gooseneck snare, but were unsuccessful because the catheter was lodged in the pulmonary artery wall. Therefore, a second attempt was made through the right femoral vein using a snare with triple loops, but we could not grasp the migrated PICC. Finally, a string was tied to the top of the snare, allowing us to curve the snare toward the pulmonary artery by pulling the string. Finally, the catheter body was grasped and retrieved. The endovascular suture technique is occasionally extremely useful and should be considered by interventional cardiologists for retrieving migrated catheters. PMID:24109502

  13. Aerosol can puncture device operational test plan

    International Nuclear Information System (INIS)

    Leist, K.J.

    1994-01-01

    Puncturing of aerosol cans is performed in the Waste Receiving and Processing Facility Module 1 (WRAP 1) process as a requirement of the waste disposal acceptance criteria for both transuranic (TRU) waste and low-level waste (LLW). These cans have contained such things as paints, lubricating oils, paint removers, insecticides, and cleaning supplies which were used in radioactive facilities. Due to Westinghouse Hanford Company (WHC) Fire Protection concerns of the baseline system's fire/explosion proof characteristics, a study was undertaken to compare the baseline system's design to commercially available puncturing devices. While the study found no areas which might indicate a risk of fire or explosion, WHC Fire Protection determined that the puncturing system must have a demonstrated record of safe operation. This could be obtained either by testing the baseline design by an independent laboratory, or by substituting a commercially available device. As a result of these efforts, the commercially available Aerosolv can puncturing device was chosen to replace the baseline design. Two concerns were raised with the system. Premature blinding of the coalescing/carbon filter, due to its proximity to the puncture and draining operation; and overpressurization of the collection bottle due to its small volume and by blinding of the filter assembly. As a result of these concerns, testing was deemed necessary. The objective of this report is to outline test procedures for the Aerosolv

  14. Transforaminal Lumbar Puncture: An Alternative Technique in Patients with Challenging Access.

    Science.gov (United States)

    Nascene, D R; Ozutemiz, C; Estby, H; McKinney, A M; Rykken, J B

    2018-05-01

    Interlaminar lumbar puncture and cervical puncture may not be ideal in all circumstances. Recently, we have used a transforaminal approach in selected situations. Between May 2016 and December 2017, twenty-six transforaminal lumbar punctures were performed in 9 patients (25 CT-guided, 1 fluoroscopy-guided). Seven had spinal muscular atrophy and were referred for intrathecal nusinersen administration. In 2, CT myelography was performed via transforaminal lumbar puncture. The lumbar posterior elements were completely fused in 8, and there was an overlying abscess in 1. The L1-2 level was used in 2; the L2-3 level, in 10; the L3-4 level, in 12; and the L4-5 level, in 2 procedures. Post-lumbar puncture headache was observed on 4 occasions, which resolved without blood patching. One patient felt heat and pain at the injection site that resolved spontaneously within hours. One patient had radicular pain that resolved with conservative treatment. Transforaminal lumbar puncture may become an effective alternative to classic interlaminar lumbar puncture or cervical puncture. © 2018 by American Journal of Neuroradiology.

  15. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  16. Obesity: An Independent Risk Factor for Insufficient Hemostasis Using the AngioSeal Vascular Closure Device After Antegrade Puncture

    Energy Technology Data Exchange (ETDEWEB)

    Minko, Peter, E-mail: peterminko@yahoo.com; Katoh, Marcus [University Hospital Saarland, Department of Diagnostic and Interventional Radiology (Germany); Graeber, Stefan [University Hospital Saarland, Institute of Medical Biometry, Epidemiology and Medical Informatics (Germany); Buecker, Arno [University Hospital Saarland, Department of Diagnostic and Interventional Radiology (Germany)

    2012-08-15

    Purpose: This study was designed to investigate the efficacy of the AngioSeal vascular closure device after antegrade puncture of the femoral artery. Methods: In a prospective study, 120 consecutive patients underwent lower limb vascular intervention by an antegrade access to the common femoral artery (CFA). After intervention, a 6F (n = 88) or an 8F (n = 32) AngioSeal vascular closure device was used to achieve hemostasis. The technical success or the cause of failure was documented. In addition, the coagulation status (platelets, INR, prothrombin time, atrial thromboplastin time (PTT)), hypertonus, locoregional habitus of the groin, body mass index (BMI), presence of calcifications, and history of previous surgical interventions of the CFA were evaluated. Results: Hemostasis was achieved in 97 patients (81%). In 12 patients (10%), persistent bleeding of the puncture site required manual compression. In another nine patients (8%) a kink of the sheath obviated the passage of the collagen plug toward the vessel, and in two patients the anchor dislodged out of the vessel, requiring manual compression. There were no significant differences between the groups of successful and unsuccessful sealing regarding the mean platelets (241 vs. 254 * 10{sup 9}/l; P = 0.86), INR (1.06 vs. 1.02; P = 0.52), prothrombin time (90% vs. 90%; P = 0.86), and PTT (30 vs. 31 s; P = 0.82). However, unsuccessful sealing was more likely in obese patients with an increased BMI (26.6 vs. 28.8 kg/m{sup 2}; P = 0.04). Conclusions: Obesity seems to be an independent risk factor for insufficient sealing using the AngioSeal vascular closure device after antegrade puncture of the CFA. In 8% of our patients, hemostasis could not be achieved due to kink of the flexible sheath.

  17. Maass Cusp Forms on Singly Punctured Two-Torus

    International Nuclear Information System (INIS)

    Siddig, Abubaker Ahmed Mohamed; Shah, Nurisya Mohd; Zainuddin, Hishamuddin

    2009-01-01

    Quantum mechanical systems on punctured surfaces modeled by hyperbolic spaces can play an interesting role in exploring quantum chaos and in studying behaviour of future quantum nano-devices. The case of singly-punctured two-torus, for example, has been well-studied in the literature particularly for its scattering states. However, the bound states on the punctured torus given by Maass cusp forms are lesser known. In this note, we report on the algorithm of numerically computing these functions and we present ten lower-lying eigenvalues for each odd and even Maass cusp forms.

  18. Hybrid treatment of a true thyreocervical trunk aneurysm in a patient with Type B aortic dissection

    Directory of Open Access Journals (Sweden)

    Nikolaos G Baikoussis

    2016-01-01

    Full Text Available We would like to describe a case with a complex aortic disease treated in hybrid fashion. We present an interesting case of a 65-year-old man with a medical history of hypertension, hyperlipidemia, and coronary artery disease percutaneously treated. An acute Type B aortic dissection occurred and treated with the implantation of a stent-graft which occluded the left subclavian artery due to its extension to the aortic arch. This event required a carotid-subclavian artery bypass due to ischemia of the left arm. An aneurysm in the innominate artery also detected, was treated with another stent-graft implantation 3 months later. At 5-year follow-up, an aneurysm of the thyreocervical trunk was found while the stent-graft of the aorta was well-tolerated without endoleak and the carotid-subclavian graft was patent. The aneurysm was asymptomatic but considering the risk of spontaneous rupture of an aneurysm of this size, elective surgery was indicated. Because the aneurysm was very close to the brachiocephalic bifurcation, open surgical repair would require a sternotomy. The right common carotid artery and right subclavian artery were exposed. The thyrocervical trunk, right internal mammary artery and right vertebral artery were occluded by ligations to isolate the aneurysm. An 8-mm Dacron graft was anastomosed end-to-end to the distal part of subclavian artery. We would like through this case, discuss the role of the hybrid cardiovascular surgery to minimize the postoperative complications in complex cardiovascular pathology. We also discuss the international bibliography about the thyreocervical trunk aneurysm and the treatment options.

  19. First clinical experience with Celt ACD(®) : a femoral arterial puncture closure device.

    LENUS (Irish Health Repository)

    Jan, Aftab

    2013-08-01

    This prospective nonrandomized study compared the safety and efficacy of a novel arterial closure device (ACD) in common femoral artery procedures to that of the FDA submitted historical manual pressure control group, who underwent either a diagnostic angiogram (DA) or a percutaneous coronary intervention (PCI) procedure.

  20. Higher-dimensional puncture initial data

    International Nuclear Information System (INIS)

    Zilhao, Miguel; Ansorg, Marcus; Cardoso, Vitor; Gualtieri, Leonardo; Herdeiro, Carlos; Sperhake, Ulrich; Witek, Helvi

    2011-01-01

    We calculate puncture initial data, corresponding to single and binary black holes with linear momenta, which solve the constraint equations of D-dimensional vacuum gravity. The data are generated by a modification of the pseudospectral code presented in [M. Ansorg, B. Bruegmann, and W. Tichy, Phys. Rev. D 70, 064011 (2004).] and made available as the TwoPunctures thorn inside the Cactus computational toolkit. As examples, we exhibit convergence plots, the violation of the Hamiltonian constraint as well as the initial data for D=4,5,6,7. These initial data are the starting point to perform high-energy collisions of black holes in D dimensions.

  1. The “SAFARI” Technique Using Retrograde Access Via Peroneal Artery Access

    International Nuclear Information System (INIS)

    Zhuang, Kun Da; Tan, Seck Guan; Tay, Kiang Hiong

    2012-01-01

    The “SAFARI” technique or subintimal arterial flossing with antegrade–retrograde intervention is a method for recanalisation of chronic total occlusions (CTOs) when subintimal angioplasty fails. Retrograde access is usually obtained via the popliteal, distal anterior tibial artery (ATA)/dorsalis pedis (DP), or distal posterior tibial artery (PTA). Distal access via the peroneal artery has not been described and has a risk of continued bleeding, leading to compartment syndrome due to its deep location. We describe our experience in two patients with retrograde access via the peroneal artery and the use of balloon-assisted hemostasis for these retrograde punctures. This approach may potentially give more options for endovascular interventions in lower limb CTOs.

  2. Punctures for theories of class S{sub Γ}

    Energy Technology Data Exchange (ETDEWEB)

    Heckman, Jonathan J. [Department of Physics, University of North Carolina,Chapel Hill, NC 27599 (United States); Jefferson, Patrick; Rudelius, Tom; Vafa, Cumrun [Jefferson Physical Laboratory, Harvard University,Cambridge, MA 02138 (United States)

    2017-03-31

    With the aim of understanding compactifications of 6D superconformal field theories to four dimensions, we study punctures for theories of class S{sub Γ}. The class S{sub Γ} theories arise from M5-branes probing ℂ{sup 2}/Γ, an ADE singularity. The resulting 4D theories descend from compactification on Riemann surfaces decorated with punctures. We show that for class S{sub Γ} theories, a puncture is specified by singular boundary conditions for fields in the 5D quiver gauge theory obtained from compactification of the 6D theory on a cylinder geometry. We determine general boundary conditions and study in detail solutions with first order poles. This yields a generalization of the Nahm pole data present for 1/2 BPS punctures for theories of class S. Focusing on specific algebraic structures, we show how the standard discussion of nilpotent orbits and its connection to representations of su(2) generalizes in this broader context.

  3. Relativistic hydrodynamics in the presence of puncture black holes

    International Nuclear Information System (INIS)

    Faber, Joshua A.; Etienne, Zachariah B.; Shapiro, Stuart L.; Taniguchi, Keisuke; Baumgarte, Thomas W.

    2007-01-01

    Many of the recent numerical simulations of binary black holes in vacuum adopt the moving puncture approach. This successful approach avoids the need to impose numerical excision of the black hole interior and is easy to implement. Here we wish to explore how well the same approach can be applied to moving black hole punctures in the presence of relativistic hydrodynamic matter. First, we evolve single black hole punctures in vacuum to calibrate our Baumgarte-Shapiro-Shibata-Nakamura implementation and to confirm that the numerical solution for the exterior spacetime is invariant to any junk (i.e., constraint-violating) initial data employed in the black hole interior. Then we focus on relativistic Bondi accretion onto a moving puncture Schwarzschild black hole as a numerical test bed for our high-resolution shock-capturing relativistic hydrodynamics scheme. We find that the hydrodynamical equations can be evolved successfully in the interior without imposing numerical excision. These results help motivate the adoption of the moving puncture approach to treat the binary black hole-neutron star problem using conformal thin-sandwich initial data

  4. Operative and endovascular management of extracranial vertebral artery aneurysm in Ehlers-Danlos syndrome:a clinical dilemma--case report and literature review.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2002-01-01

    The most prevalent lesion of the vertebral artery is an atheromatous plaque located at its origin from the subclavian artery. A case of successful management of a symptomatic vertebral artery aneurysm due to Ehlers-Danlos syndrome is reported. The patient had asymptomatic posterior intracerebral artery dissection on the contralateral side. A common carotid artery to V-3 segment bypass using reversed saphenous vein graft was carried out. Avulsion of the V-2 segment occurred peroperatively and endovascular coil embolization of the vertebral artery aneurysm was performed. Endovascular equipment and training must be in the armamentarium of vascular surgeons as more complex cases are being treated, which demands new approaches for ultimate clinical success. This unique case outlines what might unexpectedly occur. Endovascular intervention as an adjuvant procedure provides a satisfactory outcome in what could have been a catastrophe.

  5. Traumatic subclavian arteriovenous fistula in a young adult

    International Nuclear Information System (INIS)

    Nazario Dolz, Ana Maria; Ibannez Casero, Marlene; Rodriguez Fernandez, Zenen; Pichin Quesada, Alexis; Lopez Martin, Jose Carlos

    2011-01-01

    The case report of a 23 year-old patient who was admitted to the General Surgery Service of 'Saturnino Lora Torres' Provincial Teaching Clinical Surgical Hospital in Santiago de Cuba with the diagnosis of traumatic pneumothorax is described, as consequence of stab wounds in the right anterior and superior region of the thorax; but then, after 48 hours, a right subclavian arteriovenous fistula, which was proven by means of x ray was diagnosed. The postoperative clinical course was favorable and the patient was discharged after 11 days, completely asymptomatic. His working activities began 2 months later.(author)

  6. Direct Puncture Embolization of Scalp Arteriovenous Malformation in a Patient with Severe Hemophilia A: A Case Report

    International Nuclear Information System (INIS)

    Lee, Kyung Mi; Kim, Eui Jong; Park, Bong Jin; Kim, Keon Ha

    2011-01-01

    We present a case of scalp arteriovenous malformation (AVM) in a patient with severe hemophilia A. The 22-year-old man presented with a pulsatile right parietal scalp mass. Digital subtraction angiography revealed an AVM in the right parietal scalp, supplied by superficial temporal and occipital arteries that drained into multiple venous structures. We successfully performed direct puncture embolization followed by surgical resection of the scalp AVM in conjunction with supplemental infusion of coagulation factor VIII before, during and after the embolization and the operation.

  7. Direct Puncture Embolization of Scalp Arteriovenous Malformation in a Patient with Severe Hemophilia A: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Mi; Kim, Eui Jong [Dept. of Radiology, Kyung Hee University Hospital, Kyung Hee University Graduate School of Medicine, Seoul (Korea, Republic of); Park, Bong Jin [Dept. of Neurosurgery, Kyung Hee University Hospital, Kyung Hee University Graduate School of Medicine, Seoul (Korea, Republic of); Kim, Keon Ha [Dept. of Radiology, Samsug Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2011-09-15

    We present a case of scalp arteriovenous malformation (AVM) in a patient with severe hemophilia A. The 22-year-old man presented with a pulsatile right parietal scalp mass. Digital subtraction angiography revealed an AVM in the right parietal scalp, supplied by superficial temporal and occipital arteries that drained into multiple venous structures. We successfully performed direct puncture embolization followed by surgical resection of the scalp AVM in conjunction with supplemental infusion of coagulation factor VIII before, during and after the embolization and the operation.

  8. The feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization for benign diseases of uterus

    International Nuclear Information System (INIS)

    Guo Wenbo; Yang Jianyong; Chen Wei; Zhuang Wenquan; Li Heping; Yao Shuzhong

    2006-01-01

    Objective: To investigate the feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization (UAE) for uterine fibroids and adenomyosis. Methods: Trans-abdominal biopsies by ultrasound guiding were performed in 62 cases of uterine fibroids or adenomyosis diagnosed pre-UAE. Multi-points in focus were punctured in single lesion and multi-points in every focus of multiple lesions were punctured. The diagnosis before UAE was made according to clinical symptoms, pelvic ultrasound and pelvic magnetic resonance imaging (MRI). The pathological diagnosis by biopsy was comparative to its clinical diagnosis before biopsy. The complications were also observed. Results: Biopsies were performed successfully in 60 cases with pathological examination, including 52 uterine fibroids and 8 adenomyosis cases. The clinical diagnosis of uterine fibroids or adenomyosis was coincident with the pathology except 2 cases of fibroids diagnosed before biopsy were failed to puncture. Conclusion: Trans-abdominal biopsy by ultrasound guiding in uterine artery embolization for benign diseases of uterus is safe and feasible. (authors)

  9. Empirical description of bronchial and nonbronchial arteries with MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hong, E-mail: yuhong.2002@hotmail.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Liu Shiyuan, E-mail: cjr.liushiyuan@vip.163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Li Huimin, E-mail: yuhongphd@163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Xiao Xiangsheng, E-mail: cjr.xxsh@vip.163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Dong Weihua, E-mail: dongweihua2000@163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China)

    2010-08-15

    Purpose: We aimed to retrospectively evaluate bronchial and nonbronchial systemic arteries using multi-detector row helical computed tomographic (MDCT) angiography in patients with pulmonary disorders. Materials and Methods: Thirty-nine patients (24 men, 15 women; mean age, 63.4 years; range, 20-82 years) with congenital and acquired pulmonary disorders of the bronchial and nonbronchial systemic arteries underwent multi-detector row helical computed tomographic angiography of the thorax using a 16-detector row scanner. Each of these patients had experienced an episode of hemoptysis. Computed tomographic angiogram data, which included maximum intensity projections, multiplanar reconstruction, and three-dimensional volume-rendered images, were used to retrospectively analyse the characteristics of the bronchial and nonbronchial systemic arteries. Results: We identified a total of 128 bronchial arteries (76 on the right side and 52 on the left) in 39 patients. We detected 42 nonbronchial systemic artery branches, including 19 internal mammary artery branches, 8 subclavian artery branches, 8 inferior phrenic artery branches, 5 intercostal artery branches, 1 thyrocervical trunk branch, and 1 celiac trunk branch. Thirty-five dilated and tortuous nonbronchial systemic arteries entered into the lung parenchyma and extended down to the lesions. Every case, except the one case of sequestration, was associated with pleural thickening where the vascular structures passed through the extrapleural fat. Conclusions: The variations in both the bronchial artery anatomy and the location and type of the nonbronchial arteries were great. Nonbronchial arteries may be a significant source of hemoptysis. MDCT angiography can be used to detect detailed anatomical information about the origins and courses of bronchial and nonbronchial systemic arteries and their pathophysiologic features.

  10. Vascular TOS—Creating a Protocol and Sticking to It

    Directory of Open Access Journals (Sweden)

    Meena Archie

    2017-06-01

    Full Text Available Thoracic Outlet Syndrome (TOS describes a set of disorders that arise from compression of the neurovascular structures that exit the thorax and enter the upper extremity. This can present as one of three subtypes: neurogenic, venous, or arterial. The objective of this section is to outline our current practice at a single, high-volume institution for venous and arterial TOS. VTOS: Patients who present within two weeks of acute deep vein thrombosis (DVT are treated with anticoagulation, venography, and thrombolysis. Those who present later are treated with a transaxillary first rib resection, then a two-week post-operative venoplasty. All patients are anticoagulated for 2 weeks after the post-operative venogram. Those with recurrent thrombosis or residual subclavian vein stenosis undergo repeat thrombolysis or venoplasty, respectively. ATOS: In patients with acute limb ischemia, we proceed with thrombolysis or open thrombectomy if there is evidence of prolonged ischemia. We then perform a staged transaxillary first rib resection followed by reconstruction of the subclavian artery. Patients who present with claudication undergo routine arterial duplex and CT angiogram to determine the pathology of the subclavian artery. They then undergo decompression and subclavian artery repair in a similar staged manner.

  11. Puncture Wounds: First Aid

    Science.gov (United States)

    ... Skin problems. In: American Medical Association Handbook of First Aid and Emergency Care. New York, N.Y.: Random House; 2009. Jan. 12, 2018 Original article: http://www.mayoclinic.org/first-aid/first-aid-puncture-wounds/basics/ART-20056665 . Mayo ...

  12. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    International Nuclear Information System (INIS)

    Goltz, J.P.; Kickuth, R.; Bastuerk, P.; Hoppe, H.; Triller, J.

    2011-01-01

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  13. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.

    Science.gov (United States)

    Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J

    2018-06-01

    Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

  14. Lumbar puncture in patients using anticoagulants and antiplatelet agents

    Directory of Open Access Journals (Sweden)

    Renan Domingues

    2016-08-01

    Full Text Available ABSTRACT The use of anticoagulants and antiplatelet agents has largely increased. Diagnostic lumbar puncture in patients taking these drugs represents a challenge considering the opposing risks of bleeding and thrombotic complications. To date there are no controlled trials, specific guidelines, nor clear recommendations in this area. In the present review we make some recommendations about lumbar puncture in patients using these drugs. Our recommendations take into consideration the pharmacology of these drugs, the thrombotic risk according to the underlying disease, and the urgency in cerebrospinal fluid analysis. Evaluating such information and a rigorous monitoring of neurological symptoms after lumbar puncture are crucial to minimize the risk of hemorrhage associated neurological deficits. An individualized patient decision-making and an effective communication between the assistant physician and the responsible for conducting the lumbar puncture are essential to minimize potential risks.

  15. Prestrain-induced Reduction in Skin Tissue Puncture Force of Microneedle

    International Nuclear Information System (INIS)

    Kim, Jonghun; Park, Sungmin; Nam, Gyungmok; Yoon, Sang-Hee

    2016-01-01

    Despite all the recent advances in biodegradable material-based microneedles, the bending and failure (especially buckling) of a biodegradable microneedle during skin tissue insertion remains a major technical hurdle for its large-scale commercialization. A reduction in skin tissue puncture force during microneedle insertion remains an essential issue in successfully developing a biodegradable microneedle. Here, we consider uniaxial and equibiaxial prestrains applied to a skin tissue as mechanophysical stimuli that can reduce the skin tissue puncture force, and investigate the effect of prestrain on the changes in skin tissue puncture force. For a porcine skin tissue similar to that of humans, the skin tissue puncture force of a flat-end microneedle is measured with a z-axis stage equipped with a load cell, which provides a force-time curve during microneedle insertion. The findings of this study lead to a quantitative characterization of the relationship between prestrain and the skin tissue puncture force

  16. Prestrain-induced Reduction in Skin Tissue Puncture Force of Microneedle

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jonghun; Park, Sungmin; Nam, Gyungmok; Yoon, Sang-Hee [Inha Univ., Incheon (Korea, Republic of)

    2016-10-15

    Despite all the recent advances in biodegradable material-based microneedles, the bending and failure (especially buckling) of a biodegradable microneedle during skin tissue insertion remains a major technical hurdle for its large-scale commercialization. A reduction in skin tissue puncture force during microneedle insertion remains an essential issue in successfully developing a biodegradable microneedle. Here, we consider uniaxial and equibiaxial prestrains applied to a skin tissue as mechanophysical stimuli that can reduce the skin tissue puncture force, and investigate the effect of prestrain on the changes in skin tissue puncture force. For a porcine skin tissue similar to that of humans, the skin tissue puncture force of a flat-end microneedle is measured with a z-axis stage equipped with a load cell, which provides a force-time curve during microneedle insertion. The findings of this study lead to a quantitative characterization of the relationship between prestrain and the skin tissue puncture force.

  17. The 'SAFARI' Technique Using Retrograde Access Via Peroneal Artery Access

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Kun Da, E-mail: zkunda@gmail.com [Singapore General Hospital, Interventional Radiology Centre (Singapore); Tan, Seck Guan [Singapore General Hospital, Department of General Surgery (Singapore); Tay, Kiang Hiong [Singapore General Hospital, Interventional Radiology Centre (Singapore)

    2012-08-15

    The 'SAFARI' technique or subintimal arterial flossing with antegrade-retrograde intervention is a method for recanalisation of chronic total occlusions (CTOs) when subintimal angioplasty fails. Retrograde access is usually obtained via the popliteal, distal anterior tibial artery (ATA)/dorsalis pedis (DP), or distal posterior tibial artery (PTA). Distal access via the peroneal artery has not been described and has a risk of continued bleeding, leading to compartment syndrome due to its deep location. We describe our experience in two patients with retrograde access via the peroneal artery and the use of balloon-assisted hemostasis for these retrograde punctures. This approach may potentially give more options for endovascular interventions in lower limb CTOs.

  18. A Case of Unrecognized Intrathoracic Placement of a Subclavian Central Venous Catheter in a Patient with Large Traumatic Hemothorax

    Directory of Open Access Journals (Sweden)

    Dina Wallin

    2015-01-01

    Full Text Available Traditional recommendations suggest placement of a subclavian central venous catheter (CVC ipsilateral to a known pneumothorax to minimize risk of bilateral pneumothorax. We present the case of a 65-year-old male with a right hemopneumothorax who was found to have intrathoracic placement of his right subclavian CVC at thoracotomy despite successful aspiration of blood and transduction of central venous pressure (CVP. We thus recommend extreme caution with the interpretation of CVC placement by blood aspiration and CVP measurement alone in patients with large volume ipsilateral hemothorax.

  19. Implantable central venous chemoport: camparision of results according to approach routes and methods

    International Nuclear Information System (INIS)

    Shin, Byung Suck; Ahn, Moon Sang

    2003-01-01

    To evaluate the results and complications of placement of implantable port according to approach routes and methods. Between April 2001 and October 2002, a total of 103 implantable chemoport was placed in 95 patients for chemotherapy using preconnected type (n=39) and attachable type (n=64). Puncture sites were left subclavian vein (n=35), right subclavian vein (n=5), left internal jugular vein (n=9), right internal jugular vein (n=54). We evaluated duration of catheterization days, complications according to approach routes and methods. Implantable chemoport was placed successfully in all cases. Duration of catheterization ranged from 8 to 554 days(mean 159, total 17,872 catheter days). Procedure related complications occurred transient pulmonary air embolism (n=1), small hematoma (n=1) and malposition in using preconnected type (n=2). Late complications occurred catheter migration (n=5), catheter malfunction (n=3), occlusion (n=1) and infection (n=11). Among them 15 chemoport was removed (14.5%). Catheter migration was occured via subclavian vein in all cases (13%, p=.008). Infection developed in 10.7% of patients(0.61 per 1000 catheter days). There were no catheter-related central vein thrombosis. Implantation of chemoport is a safe procedure. Choice of right internal jugular vein than subclavian vain vein for puncture site has less complications. And selection of attachable type of chemoport is convenient than preconnected type. Adequate care of chemoport is essential for long patency

  20. Traumatic brachiocephalic pseudoaneurysm presenting with delayed stroke: case report

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, A.; Gueckel, F. [Department of Radiology, University Hospital Mannheim, Medical Faculty of University Heidelberg (Germany); Meairs, S.; Cornelius, A.; Schwartz, A. [Department of Neurology, University Hospital Mannheim, Medical Faculty of University Heidelberg (Germany)

    2000-10-01

    We report a traumatic pseudoaneurysm of the internal carotid artery bifurcation and subclavian artery with recurrent strokes events in a 19-year-old man. He was admitted with an acute left hemiparesis. His history revealed a similar episode 1 year and a major car accident 3 years previously. Contrast enhanced MR angiography confirmed colour Doppler sonographic findings of a carotid and subclavian artery pseudoaneurysm presumably resulting from seat-belt trauma. The pseudoaneurysm, containing thrombus, was thought to be the source of artery-to-artery embolism. (orig.)

  1. Anastomoses of the Ovarian and Uterine Arteries: A Potential Pitfall and Cause of Failure of Uterine Embolization

    International Nuclear Information System (INIS)

    Matson, Matthew; Nicholson, Anthony; Belli, Anna-Maria

    2000-01-01

    Four women with symptomatic uterine fibroids were treated by uterine artery embolization (UAE). In all cases both uterine arteries were embolized via a single femoral puncture with polyvinyl alcohol using a selective catheter technique. In three cases, the ovarian artery was not visible on the initial angiogram before embolization, but appeared after the second uterine artery had been treated. In one case of clinical failure following UAE, a repeat angiogram demonstrated filling of the fibroids from the ovarian artery. Anastomoses between uterine and ovarian arteries may cause problems for radiologists performing UAE and are a potential cause of treatment failure

  2. Fuel rod puncturing and fission gas monitoring system examination techniques

    International Nuclear Information System (INIS)

    Song, Woong Sup

    1999-02-01

    Fission gas products accumulated in irradiated fuel rod is 1-2 cm 3 in CANDU and 40-50 cm 3 in PWR fuel rod. Fuel rod puncturing and fission gas monitoring system can be used for both CANDU and PWR fuel rod. This system comprises puncturing device located at in cell part and monitoring device located at out cell part. The system has computerized 9 modes and can calculate both void volume and mass volume only single puncturing. This report describes techniques and procedure for operating fuel rod puncturing and gas monitoring system which can be play an important role in successful operation of the devices. Results obtained from the analysis can give more influence over design for fuel rods. (Author). 6 refs., 9 figs

  3. A Comparison of Po2, Pco2, Ph and Bicarbonate in Blood from the Carotid and Coccygeal Arteries of Calves

    OpenAIRE

    Gustin, Pascal; de Groote, A.; Dhem, A. R.; Bakima, M.; Lomba; Lekeux, Pierre

    1988-01-01

    A technique is described for the subcutaneous deviation of the carotid artery into the jugular groove of calves weighing between 90 and 200 kg. This makes sampling arterial blood or chronic cannulation for further experimentation very easy. Values of oxygen tension, carbon dioxide tension, pH and bicarbonate concentration in blood sampled from the ventral coccygeal artery were compared with the values obtained in blood from carotid artery puncture. The high correlations observed indicate that...

  4. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  5. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  6. The Tension and Puncture Properties of HDPE Geomembrane under the Corrosion of Leachate.

    Science.gov (United States)

    Xue, Qiang; Zhang, Qian; Li, Zhen-Ze; Xiao, Kai

    2013-09-17

    To investigate the gradual failure of high-density polyethylene (HDPE) geomembrane as a result of long-term corrosion, four dynamic corrosion tests were conducted at different temperatures and durations. By combining tension and puncture tests, we systematically studied the variation law of tension and puncture properties of the HDPE geomembrane under different corrosion conditions. Results showed that tension and puncture failure of the HDPE geomembrane was progressive, and tensile strength in the longitudinal grain direction was evidently better than that in the transverse direction. Punctures appeared shortly after puncture force reached the puncture strength. The tensile strength of geomembrane was in inversely proportional to the corrosion time, and the impact of corrosion was more obvious in the longitudinal direction than transverse direction. As corrosion time increased, puncture strength decreased and corresponding deformation increased. As with corrosion time, the increase of corrosion temperature induced the decrease of geomembrane tensile strength. Tensile and puncture strength were extremely sensitive to temperature. Overall, residual strength had a negative correlation with corrosion time or temperature. Elongation variation increased initially and then decreased with the increase in temperature. However, it did not show significant law with corrosion time. The reduction in puncture strength and the increase in puncture deformation had positive correlations with corrosion time or temperature. The geomembrane softened under corrosion condition. The conclusion may be applicable to the proper designing of the HDPE geomembrane in landfill barrier system.

  7. The training and learning process of transseptal puncture using a modified technique.

    Science.gov (United States)

    Yao, Yan; Ding, Ligang; Chen, Wensheng; Guo, Jun; Bao, Jingru; Shi, Rui; Huang, Wen; Zhang, Shu; Wong, Tom

    2013-12-01

    As the transseptal (TS) puncture has become an integral part of many types of cardiac interventional procedures, its technique that was initial reported for measurement of left atrial pressure in 1950s, continue to evolve. Our laboratory adopted a modified technique which uses only coronary sinus catheter as the landmark to accomplishing TS punctures under fluoroscopy. The aim of this study is prospectively to evaluate the training and learning process for TS puncture guided by this modified technique. Guided by the training protocol, TS puncture was performed in 120 consecutive patients by three trainees without previous personal experience in TS catheterization and one experienced trainer as a controller. We analysed the following parameters: one puncture success rate, total procedure time, fluoroscopic time, and radiation dose. The learning curve was analysed using curve-fitting methodology. The first attempt at TS crossing was successful in 74 (82%), a second attempt was successful in 11 (12%), and 5 patients failed to puncture the interatrial septal finally. The average starting process time was 4.1 ± 0.8 min, and the estimated mean learning plateau was 1.2 ± 0.2 min. The estimated mean learning rate for process time was 25 ± 3 cases. Important aspects of learning curve can be estimated by fitting inverse curves for TS puncture. The study demonstrated that this technique was a simple, safe, economic, and effective approach for learning of TS puncture. Base on the statistical analysis, approximately 29 TS punctures will be needed for trainee to pass the steepest area of learning curve.

  8. The reasons for delay lumbar puncture

    Directory of Open Access Journals (Sweden)

    MH. Lotfi

    2017-04-01

    Full Text Available Early diagnosis of meningitis and encephalitis and prompt initiation of appropriate therapy is vital and any delay will lead to high mortality and serious and permanent morbidity. The main purpose of this study was to evaluate the management of 220 patients with suspected central nervous system (CNS infections (meningitis and encephalitis to determine the percentage of patients’ suspected CNS infection undergo lumbar puncture in acceptable time (in accordance with conventional algorithms. In this descriptive study, patients with suspected CNS infections admitted to Bu-Ali and Qods hospitals, in the period July 2013 to December 2015 were studied. Information of 220 patients was collected. Continuous variables were summarized as means ± standard deviation and categorical variables as frequencies and percentages. Lumbar puncture (LP in patients was delayed in 200 cases (91%. Most common causes of delay in performing LP were prolongation of the process of determining patient needs to puncture, satisfying patients, CT scan delay and the delay in allowing LP by neurologist. In this study, delaying LP rate was higher than other studies. It seems certain pattern in assistants’ visits for counseling. CT requests and neurologic consultation before LP performed for all adult patients.

  9. Video-assisted thoracoscopic left lower lobectomy in a patient with lung cancer and a right aortic arch

    Directory of Open Access Journals (Sweden)

    Wada Hideyuki

    2012-11-01

    Full Text Available Abstract A right aortic arch is a rare congenital anomaly, with a reported incidence of around 0.1%. A patient with a right aortic arch underwent video-assisted thoracic surgery left lower lobectomy and mediastinal lymph node dissection for squamous cell carcinoma. There was no aortic arch or descending aorta in the left thoracic cavity, but the esophagus. There was no anomaly in the location or branching of the pulmonary vessels, the bronchi, and the lobulation of the lungs. The vagus nerve was found at the level of the left pulmonary artery. The arterial ligament was found between the left subclavian artery and the left pulmonary artery. The recurrent laryngeal nerve was recurrent around the left subclavian artery. A Kommerell diverticulum was found at the origin of the left subclavian artery. The patient experienced no complications. We conclude that video-assisted thoracoscopic lobectomy with mediastinal dissection is feasible for treating lung cancer with a right aortic arch.

  10. Focal hot spot induced by a central subclavian line on bone scan.

    Science.gov (United States)

    Moslehi, Masood; Cheki, Mohsen; Dehghani, Tohid; Eftekhari, Mansoureh

    2014-01-01

    The diagnostic accuracy of nuclear medicine reporting can be improved by awareness of these instrument-related artifacts. Both awareness and experience are also important when it comes to detecting and identifying normal (and abnormal) variants. We present a case of hot spot on the upper right chest in the region of right subclavicular region resulting from injection of radiotracer from central subclavian line. A 52-year-old woman with a history of left breast cancer and recent bone pain was referred to our nuclear medicine department for skeletal survey. Anterior views of chest show a focus of increased radiotracer uptake corresponding to anterior arch of one of the right second rib. The nuclear physician reported it as a focal rib bony lesion and recommended radiological evaluation. As technician later explained, physicians realized that injection site was a central subclavian line on the right side and hot spot on that region is due to injection site. The appearance of both skeletal and soft-tissue uptake depends heavily on imaging technique (such as the route of radiotracer administration) and the interpreting physicians should be aware of the impact of technical factors on image quality.

  11. Cerebrospinal fluid loss at lumbar puncture for caesarean section ...

    African Journals Online (AJOL)

    Background Post dural puncture headache (PDPH) is an unpleasant complication of spinal anaesthesia. Several studies have attempted explanation of its pathophysiology. A widely held view is that it results from loss of cerebrospinal fluid volume resulting from leak following a hole left in the dura after the puncture.

  12. A new device of CT-targeted percutaneous punctures

    International Nuclear Information System (INIS)

    Ozdoba, C.

    1990-01-01

    This paper reports on a device for CT-targeted percutaneous punctures. After extensive phantom studies, punctures of vertebral disk space (diskography/nucleotomy) and orbit retrobulbar anesthesia/biopsy were performed in 15 patients. The new device is easy to mount on the CT scanner and does not require additional devices affixed to the patient. Its design and construction permit exact calculation of needle angle and depth, even when the gantry is tilted. Percutaneous biopsies can be performed in approximately 40 minutes. The device is accurate within ±0.5 mm, thereby allowing puncture of even small lesions deep in the orbital cone. Retrobulbar anesthesia can be performed safely in patients with a long myopic bulbus; in nucleotomy, instant control of the instrument's position within the disk space is possible

  13. Chronic Expanding Hematoma in the Popliteal Fossa after Pseudoaneurysm Surgery because of Nail Puncture

    Directory of Open Access Journals (Sweden)

    Serdar Yilmaz

    2014-01-01

    Full Text Available Hematomas caused by surgery or trauma that persist and expand slowly for more than a month are defined as chronic expanding hematomas (CEH. Magnetic resonance imaging (MRI is useful for the diagnosis. Total excision with the pseudocapsule is the treatment method. Pseudoaneurysms result from arterial wall disruptions and can be mistaken for CEH. We present a rare case report of a 45-year-old man with a large, painful swelling in his left popliteal fossa. He had a puncture wound by a nail 11 years ago and a gradually expanding mass occurred in his popliteal fossa. A pseudoaneurysm was detected and operated a year later. After surgery, a gradually expanding mass recurred in his popliteal fossa. On the arteriography, the popliteal artery was occluded and the blood flow was maintained with collateral vessels. On MRI, an enormous swelling of 115 × 107 × 196 cm in diameter was seen. It was diagnosed as CEH and was excised completely protecting the collateral vessels and there was no recurrence after a year from the surgery.

  14. Successful surgical repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery with prior reconstruction of the carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Miyahara, Ken; Maeda, Masanobu; Sakai, Yoshimasa; Sakurai, Hajime; Murayama, Hiroomi; Hasegawa, Hiroki [Social Insurance Chukyo Hospital, Nagoya (Japan)

    2003-01-01

    We report the successful repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery (BCA) in a 70-year-old man. He had undergone a mediastinal tumor resection through a median sternotomy in 1995. Pathological examination revealed non-Hodgkin's lymphoma. Two years later, he underwent radiation therapy of 65 Gray for metastasis to the supraclavicular lymph nodes. On January 18, 2000, plastic surgeons planned to perform a pectoralis major musculocutaneous flap to repair a radiation skin ulcer. During the operation, the BCA was lacerated, possibly in an area of radiation tissue damage. We performed a prosthetic graft (10-mm Gelseal) replacement of the BCA. The right subclavian artery had to be ligated. Postoperative digital subtraction angiography (DSA) showed excellent reconstruction of the artery. Magnetic resonance angiography of the brain showed a deficit in the anterior communicating artery and stenosis of the posterior communicating artery, which indicated that the reconstruction procedure was reasonable. Seven months later, on August 18, 2000, the patient was transferred to our hospital because of swelling of the right neck and oozing from the previous cutaneous wound. CT scan and DSA demonstrated the presence of a pseudoaneurysm of the proximal anastomosis site, which required emergency surgery. Before this third sternotomy, a saphenous vein graft was interposed between both external carotid arteries. Removal of the prosthetic graft and resection of the pseudoaneurysm were performed under mild hypothermia and cardiopulmonary bypass with left common carotid arterial perfusion. Then, the wound was closed completely using a left pectoralis major musculocutaneous flap. The postoperative course was uneventful and DSA showed good patency of the graft and intracranial arteries. The patient was discharged without neurological complications. We conclude that prior reconstruction of the carotid artery is a safe and effective procedure for patients

  15. Successful surgical repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery with prior reconstruction of the carotid artery

    International Nuclear Information System (INIS)

    Miyahara, Ken; Maeda, Masanobu; Sakai, Yoshimasa; Sakurai, Hajime; Murayama, Hiroomi; Hasegawa, Hiroki

    2003-01-01

    We report the successful repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery (BCA) in a 70-year-old man. He had undergone a mediastinal tumor resection through a median sternotomy in 1995. Pathological examination revealed non-Hodgkin's lymphoma. Two years later, he underwent radiation therapy of 65 Gray for metastasis to the supraclavicular lymph nodes. On January 18, 2000, plastic surgeons planned to perform a pectoralis major musculocutaneous flap to repair a radiation skin ulcer. During the operation, the BCA was lacerated, possibly in an area of radiation tissue damage. We performed a prosthetic graft (10-mm Gelseal) replacement of the BCA. The right subclavian artery had to be ligated. Postoperative digital subtraction angiography (DSA) showed excellent reconstruction of the artery. Magnetic resonance angiography of the brain showed a deficit in the anterior communicating artery and stenosis of the posterior communicating artery, which indicated that the reconstruction procedure was reasonable. Seven months later, on August 18, 2000, the patient was transferred to our hospital because of swelling of the right neck and oozing from the previous cutaneous wound. CT scan and DSA demonstrated the presence of a pseudoaneurysm of the proximal anastomosis site, which required emergency surgery. Before this third sternotomy, a saphenous vein graft was interposed between both external carotid arteries. Removal of the prosthetic graft and resection of the pseudoaneurysm were performed under mild hypothermia and cardiopulmonary bypass with left common carotid arterial perfusion. Then, the wound was closed completely using a left pectoralis major musculocutaneous flap. The postoperative course was uneventful and DSA showed good patency of the graft and intracranial arteries. The patient was discharged without neurological complications. We conclude that prior reconstruction of the carotid artery is a safe and effective procedure for patients with

  16. Quasi-static puncture resistance behaviors of high-strength polyester fabric for soft body armor

    Directory of Open Access Journals (Sweden)

    Qiu-Shi Wang

    Full Text Available A series of economical and flexible fabrics were prepared using high-strength polyester yarns with different fabric structures, weft density and number of layers. The effect of these factors on quasi-static puncture resistance was comparatively studied. The failure mode of the fabrics was analyzed with SEM photographs. Findings indicate that the structure and the weft density affected the quasi-static puncture resistance property of the fabrics, the plain fabrics had better puncture resistance property than twill and satin fabrics. The max puncture force and puncture energy of the plain fabrics with 160 yarn/10 cm reached the max values which were 107.43 N and 0.44 J, respectively. The number of layers had a linear relationship to quasi-static puncture resistance. The contact pressure and friction of the probe against the fibers were the main hindrance during the quasi-static puncture process and the breakage of the fibers during the penetration was caused by the bend and tensile deformation. Keywords: High-strength polyester fabrics, Fabric structure, Multiple-layer fabrics, Quasi-static puncture resistance

  17. Puncture Self-Healing Polymers for Aerospace Applications

    Science.gov (United States)

    Gordon, Keith L.; Penner, Ronald K.; Bogert, Phil B.; Yost, W. T.; Siochi, Emilie J.

    2011-01-01

    Space exploration launch costs on the order of $10K per pound provide ample incentive to seek innovative, cost-effective ways to reduce structural mass without sacrificing safety and reliability. Damage-tolerant structural systems can provide a route to avoiding weight penalty while enhancing vehicle safety and reliability. Self-healing polymers capable of spontaneous puncture repair show great promise to mitigate potentially catastrophic damage from events such as micrometeoroid penetration. Effective self-repair requires these materials to heal instantaneously following projectile penetration while retaining structural integrity. Poly(ethylene-co-methacrylic acid) (EMMA), also known as Surlyn is an ionomer-based copolymer that undergoes puncture reversal (self-healing) following high impact puncture at high velocities. However EMMA is not a structural engineering polymer, and will not meet the demands of aerospace applications requiring self-healing engineering materials. Current efforts to identify candidate self-healing polymer materials for structural engineering systems are reported. Rheology, high speed thermography, and high speed video for self-healing semi-crystalline and amorphous polymers will be reported.

  18. CT guided puncture aspiration and sclerosing treatment of ovary cyst

    International Nuclear Information System (INIS)

    Peng Yongjun; Du Xiumei; Yuan Jinrong; Chen Chanqing

    2007-01-01

    Objective: To analyze the method and the curative effect with CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst. Method: 22 ovary cysts in 22 patients were treated with percutaneous puncture aspiration and underwent repeated sclerotherapy with 99.7% ethanol injection. Among the 22 patients, 18 patients had solitary ovary cyst and was aspirated with an 18-22G gauge aspiration needle. The amount of aspirated fluid varied from 30ml-500ml and 25%-30% cyst volume was replaced by appropriate ethanol Post treatment follow-up were achieved every 3 months. Results All the Punctures were successfully completed. During the 3 months to one year follow-up, 16 ovary cyst disappeared, 6 cysts were small over 50%, without main complication. Conclusion CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst is a treatment of choice because of its safety, low complication, and high curative effect. (authors)

  19. Brachial artery approach for outpatient arteriography

    International Nuclear Information System (INIS)

    You, Jai Kyung; Park, Sung Il; Lee, Do Yun; Won, Jae Hwan

    1999-01-01

    To evaluate the diagnostic usefulness of brachial approach arteriography for outpatients, with particular regard to safety and image quality. The angiographic findings and follow-up medical records of 131 brachial approach arteriographies in 121 outpatients were retrospectively analysed. 5 F pigtail catheters were used in 125 cases and 5-F OCU-A catheters were used in three cases of renal arteriography, and three of upper extremity arteriography without catheter. Except for three cases of brachial artery puncture failure, all procedures were performed successfully. One hundred and fifteen of 119 lower extremity arteriographies were visualized down to the level of the tibioperoneal artery. The non-visualized cases were three in which there was multiple obstruction at the distal common iliac artery and one with insufficient contrast amount due to renal failure In four cases there were complications : two involved arterial thrombosis, one was an intramuscular hematoma, and one an A-V fistula. For outpatients, brachial approach arteriography can replace the femoral approach. Its image quality is excellent, there are time-cost benefits, and the rate of complications is relatively low

  20. Discussion on the method to increase the successful rate of L5/S1 intervertebral disc puncture

    International Nuclear Information System (INIS)

    Zhong Xianyi; Li Liangjun; Yu Chengxin

    2007-01-01

    Objective: To study the effective methods of L 5 /S 1 intervertebral disc puncture without drilling to solve the barriers from iliaca. Methods: (1) puncturing with belly-buttock sticking out: to enlarge waist sacro-iliaca angle to move the puncture point up; (2) puncturing through intervertebral edge: puncturing through L 5 to 1/3 intervertebral disc to make the puncture point move Up; (3) puncturing through L 5 /S 1 intervertebral disc with the self-made puncture location instrument. Results with the methods, 280 cases with L 5 /S 1 intervertebral disc protrusion have been successfully punctured, with successful rate 100%. Conclusion: These methods are ideal and easy to use to treat L 5 /S 1 intervertebral disc protrusion puncture, and worth popularizing. (authors)

  1. Cerebellar Herniation after Lumbar Puncture in Galactosemic Newborn

    Directory of Open Access Journals (Sweden)

    Salih Kalay

    2011-09-01

    Full Text Available Cerebral edema resulting in elevated intracranial pressure is a well-known complication of galactosemia. Lumbar puncture was performed for the diagnosis of clinically suspected bacterial meningitis. Herniation of cerebral tissue through the foramen magnum is not a common problem in neonatal intensive care units because of the open fontanelle in infants. We present the case of a 3-week-old infant with galactosemia who presented with signs of cerebellar herniation after lumbar puncture.

  2. Technological advances and changing indications for lumbar puncture in neurological disorders.

    Science.gov (United States)

    Costerus, Joost M; Brouwer, Matthijs C; van de Beek, Diederik

    2018-03-01

    Technological advances have changed the indications for and the way in which lumbar puncture is done. Suspected CNS infection remains the most common indication for lumbar puncture, but new molecular techniques have broadened CSF analysis indications, such as the determination of neuronal autoantibodies in autoimmune encephalitis. New screening techniques have increased sensitvity for pathogen detection and can be used to identify pathogens that were previously unknown to cause CNS infections. Evidence suggests that potential treatments for neurodegenerative diseases, such as Alzheimer's disease, will rely on early detection of the disease with the use of CSF biomarkers. In addition to being used as a diagnostic tool, lumbar puncture can also be used to administer intrathecal treatments as shown by studies of antisense oligonucleotides in patients with spinal muscular atrophy. Lumbar puncture is generally a safe procedure but complications can occur, ranging from minor (eg, back pain) to potentially devastating (eg, cerebral herniation). Evidence that an atraumatic needle tip design reduces complications of lumbar puncture is compelling, and reinforces the need to change clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Popliteal artery puncture in the assessment of patients with severe leg ischemia

    DEFF Research Database (Denmark)

    Agerskov, K; Faris, I; Tønnesen, K H

    1983-01-01

    Two-plane angiography and direct segmental pressure measurements in the femoral and popliteal arteries and indirectly on the arm and ankle were performed in 101 limbs seeking to establish a relationship between angiographic assessment of the patency of the popliteal artery and the trifurcation...... vessels and the popliteal ankle pressure difference. When the tiberoperoneal trunk or the trifurcation vessels were occluded or more than 50% of the lumen was stenosed, the pressure difference exceeded 10 mmHg in 30/40 limbs (75%). When three, two, or only one of the tibial vessels were patent......, the pressure difference exceeded 10 mmHg in 2/58 limbs (3%). One month following above knee femoropopliteal bypass (48 limbs), patients with a popliteal-ankle difference less than 10 mmHg obtained a significantly higher ankle pressure index (PI 0.86, range 0.56-1.20) (p less than 0.01) than those...

  4. Use of Lumbar Punctures in the Management of Ocular Syphilis.

    Science.gov (United States)

    Reekie, Ian; Reddy, Yaviche

    2018-01-01

    Ocular syphilis has become rare in the developed world, but is a common presentation to ophthalmology departments in South Africa. We investigated the proportion of patients diagnosed with ocular syphilis who went on to receive lumbar punctures, and determined the fraction of these who had cerebrospinal fluid findings suggestive of neurosyphilis. We aimed to determine whether the use of lumbar punctures in ocular syphilis patients was beneficial in picking up cases of neurosyphilis. Retrospective study of case notes of patients admitted to two district hospitals in Durban, South Africa, with ocular syphilis over a 20-month period. A total of 31 of 68 ocular syphilis patients underwent lumbar puncture, and of these, eight (25.8%) had findings suggestive of neurosyphilis. Lumbar puncture in ocular syphilis patients should continue to be a routine part of the investigation of these patients; a large proportion of ocular syphilis patients show cerebrospinal fluid findings suggestive of neurosyphilis, are at risk of the complications of neurosyphilis, and should be managed accordingly.

  5. Secondary tracheoesophageal puncture in-office using Seldinger technique.

    Science.gov (United States)

    Britt, Christopher J; Lippert, Dylan; Kammer, Rachael; Ford, Charles N; Dailey, Seth H; McCulloch, Timothy; Hartig, Gregory

    2014-05-01

    Evaluate the safety and efficacy of in-office secondary tracheoesophageal puncture (TEP) technique using transnasal esophagoscopy (TNE) and the Seldinger technique in conjunction with a cricothyroidotomy kit for placement. Case series with chart review. Academic medical center. A retrospective chart review was performed on 83 subjects who underwent in-office secondary TEP. Variables that were examined included disease site, staging, histologic diagnosis, extent of resection and reconstruction, chemoradiation, functional voice status (as assessed by speech pathologist in most recent note), and complications directly related to the procedure. Eighty-three individuals from our institution met our criteria for in-office secondary TEP from 2005 to August 2012. Of these, 97.6% (81/83) had no complications of TEP. The overall complication rate was 2.4% (2/83). Complications included bleeding from puncture site and closure of puncture site after dislodgement of prosthesis at the time of puncture. Fluent conversational speech was achieved in 69.9% of all patients (58/83), and an additional 19.3% (16/83) achieved functional/intelligible speech; of those, 3.6% (3/83) were unable to achieve fluent conversational speech due to anatomic defects from previous surgery. An in-office TEP can be safely performed using the Seldinger technique with direct visualization using TNE, despite the extent of resection or reconstruction, with functional speech outcomes comparable to other studies available in the literature.

  6. Understanding of percutaneous puncture under guidance of ultrasound in treating peritoneal and perinephritic abscess

    International Nuclear Information System (INIS)

    Huang Liying; Wang Jiagang

    2010-01-01

    Objective: To explore the clinical value of percutaneous puncture under guidance of ultrasound in treating peritoneal abscess. Methods: To summarize 68 patients with peritoneal abscess underwent percutaneous puncture under guidance of ultrasound to analyse the method of operation and therapeutic effect. Results: effective power of percutaneous puncture under guidance of ultrasound in treating peritoneal abscess was 96.8%. Conclusion: Percutaneous puncture under guidance of ultrasound in treating peritoneal abscess may avoid injury induced by blinded puncture, with characteristic of easier operation, slighter trauma. higher safety, significant therapeutic effect, and can be spreaded to the clinical application. (authors)

  7. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance

    Directory of Open Access Journals (Sweden)

    Zolnierczyk P

    2015-05-01

    Full Text Available Piotr Zolnierczyk, Krzysztof Cendrowski, Wlodzimierz Sawicki Department of Obstetrics, Gynecology and Oncology, 2nd Faculty of Medicine, Medical University of Warsaw, Warsaw, Poland Abstract: This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index – 38, congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic–therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations. Keywords: ovarian cyst puncture, hysteroscopy, ultrasound guided puncture, transfundal cyst puncture, vaginoscopy 

  8. Puncture mechanics of soft elastomeric membrane with large deformation by rigid cylindrical indenter

    Science.gov (United States)

    Liu, Junjie; Chen, Zhe; Liang, Xueya; Huang, Xiaoqiang; Mao, Guoyong; Hong, Wei; Yu, Honghui; Qu, Shaoxing

    2018-03-01

    Soft elastomeric membrane structures are widely used and commonly found in engineering and biological applications. Puncture is one of the primary failure modes of soft elastomeric membrane at large deformation when indented by rigid objects. In order to investigate the puncture failure mechanism of soft elastomeric membrane with large deformation, we study the deformation and puncture failure of silicone rubber membrane that results from the continuous axisymmetric indentation by cylindrical steel indenters experimentally and analytically. In the experiment, effects of indenter size and the friction between the indenter and the membrane on the deformation and puncture failure of the membrane are investigated. In the analytical study, a model within the framework of nonlinear field theory is developed to describe the large local deformation around the punctured area, as well as to predict the puncture failure of the membrane. The deformed membrane is divided into three parts and the friction contact between the membrane and indenter is modeled by Coulomb friction law. The first invariant of the right Cauchy-Green deformation tensor I1 is adopted to predict the puncture failure of the membrane. The experimental and analytical results agree well. This work provides a guideline in designing reliable soft devices featured with membrane structures, which are present in a wide variety of applications.

  9. Use of a vegetable model as a training tool for PCNL puncture.

    Science.gov (United States)

    Sinha, Maneesh; Krishnamoorthy, Venkatesh

    2015-01-01

    Training residents to perform a PCNL puncture is hampered by the non-availability of a good inanimate model that can be used for demonstration and practice. The ethics of surgical training during actual surgeries is being questioned and the role of simulation is increasingly important. Virtual reality trainers, however, are prohibitively expensive and the use of animal models is fraught with regulatory and ethical concerns. We have devised a model that can be used to teach the concept of depth perception during a PCNL puncture. A bottle gourd was used to mimic the posterior abdominal wall. Cotton pledgets dipped in intravenous contrast were fitted into 4 mm holes made at staggered levels in the bottle gourd which was strapped onto the operating table with the cotton pledgets facing away from the surgeon. Surgeons with varying degrees of experience made fluoroscopy-guided punctures onto the cotton pledgets. We recorded the time taken for puncture in seconds and the distance of the needle exit site from the center of the cotton ball. Speed was measured by recording the fluoroscopy time in seconds on the C-arm. Accuracy was documented by using a Vernier caliper to measure the distance from the edge of the target to the actual puncture. One second of fluoroscopy time and 0.1 mm distance were each given one point. The total points accumulated over a set of 10 punctures was added to give a total score. Longer fluoroscopy times and inaccurate punctures resulted in higher scores. A surgeon with more than 1000 PCNLs to his credit had a score of 99. The average score of five residents was 555. The bottle gourd model provides an ethically acceptable, inexpensive, easy to replicate model that can be used to train residents in the PCNL puncture.

  10. Subclavian vein thrombosis following fracture of the clavicle: case report

    OpenAIRE

    Terra, Bernardo Barcellos; Cocco, Luiz Fernando; Ejnisman, Benno; Fernandes, Hélio Jorge Alvachian; Reis, Fernando Baldy dos

    2011-01-01

    A trombose venosa profunda no membro superior não é frequente na literatura ortopédica. Relatamos um caso de trombose da veia subclávia durante o tratamento conservador de fratura do terço médio da clavícula. O diagnóstico é difícil e requer um alto grau de suspeição e o tratamento pode prevenir um tromboembolismo fatal. Há raros casos descritos associados à fratura de clavícula.Deep vein thrombosis in the upper limbs is uncommon in the orthopedic literature. We report on a case of subclavian...

  11. Liouville theory and uniformization of four-punctured sphere

    Science.gov (United States)

    Hadasz, Leszek; Jaskólski, Zbigniew

    2006-08-01

    A few years ago Zamolodchikov and Zamolodchikov proposed an expression for the four-point classical Liouville action in terms of the three-point actions and the classical conformal block [Nucl. Phys. B 477, 577 (1996)]. In this paper we develop a method of calculating the uniformizing map and the uniformizing group from the classical Liouville action on n-punctured sphere and discuss the consequences of Zamolodchikovs conjecture for an explicit construction of the uniformizing map and the uniformizing group for the sphere with four punctures.

  12. Rare patterns of dorsal puncture in Pterostichus oblongopunctatus (Coleoptera: Carabidae

    Directory of Open Access Journals (Sweden)

    Axel Schwerk

    2018-04-01

    Full Text Available Background The carabid beetle species Pterostichus oblongopunctatus is common in different types of forests in Poland and Europe. With respect to this species, some unclarities exist concerning the morphological feature of punctures on the elytra. P. oblongopunctatus has dorsal pits in the third interval of the elytra, the available identification keys, however, provide inconsistent information concerning the puncture in other intervals. During long-term studies at different study sites in Poland, the first author rarely but regularly discovered individuals with unusual dorsal puncture patterns, i.e., pits in the fifth and even in the seventh interval of the elytra. Since such rare patterns might be connected with special habitat characteristics, and thus have a potential as an indicator, the aim of the study was to test if they are connected with specific subpopulations (interaction groups, if they are related to the sex or size of the beetles, and if they are related to specific habitat conditions. Material and Methods We counted the pits on the elytra, determined the sex, and measured the length of the right elytron of individuals of P. oblongopunctatus collected at numerous study sites located within the borders of the Regional Directory of National Forests in Piła (Western Poland over the period 2014–2016. Results Altogether, 1,058 individuals of P. oblongopunctatus were subjected to statistical analysis. Almost 19% of the individuals had a dorsal puncture in the fifth interval of the elytra and about 0.7% had a dorsal puncture in the seventh interval of the elytra. In 2014 and 2015, significantly more females exhibited such unusual patterns of dorsal puncture than males. Even if not statistically significant, in 2016 also relatively more females showed such a pattern. Neither males nor females of the analysed individuals with usual puncture patterns showed a significant difference in the length of the right elytron from those with

  13. Importance of absent ductus arteriosus in tetralogy of Fallot with absent pulmonary valve syndrome.

    Science.gov (United States)

    Qureshi, Muhammad Yasir; Burkhart, Harold M; Julsrud, Paul; Cetta, Frank

    2014-12-01

    Tetralogy of Fallot without pulmonary valve syndrome is almost always associated with an absent ductus arteriosus. Patients with right aortic arch and retroesophageal left subclavian artery have a vascular ring if the left ductus arteriosus or its remnant and the Kommerell diverticulum are present. We report the cases of 2 infants in whom the role of an absent ductus arteriosus or its remnant is noteworthy. Both patients had a combination of tetralogy of Fallot with absent pulmonary valve syndrome and right aortic arch with retroesophageal left subclavian artery without a vascular ring. The absence of the ductus arteriosus has a role in the pathogenesis of tetralogy of Fallot with absent pulmonary valve syndrome. The absence of a ductus arteriosus in the right aortic arch with retroesophageal left subclavian artery precludes a vascular ring.

  14. Management Strategy for Patients With Chronic Subclavian Vein Thrombosis.

    Science.gov (United States)

    Keir, Graham; Marshall, M Blair

    2017-02-01

    We performed a systematic review to determine best practice for the management of patients with chronic or subacute subclavian vein thrombosis. This condition is best managed with surgical excision of the first rib followed by long-term anticoagulation. Interventional techniques aimed at restoring patency are ineffective beyond 2 weeks postthrombosis. Additional therapeutic options should be made based on the severity of symptoms as well as vein status. Patients with milder symptoms are given decompression surgery followed by anticoagulation whereas patients with more severe symptoms are considered for either a jugular vein transposition or saphenous patch based on the vein characteristics. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. The transabdominal chorionic villus sampling puncture guided by color Doppler ultrasound during early pregnancy

    International Nuclear Information System (INIS)

    Liang Weixiang; Chen Zhiyi; Yuan Wenlin; Cai Kuan; Zhu Junlin; Wang Weiqun; Chen Xia

    2008-01-01

    Objective: To study the operation of chorionic villus sampling (CVS) guided by color Doppler ultrasound (CDU) via abdomen puncture during early pregnancy and investigate the advertences during the operation. Methods: CVS guided by CDU probe via abdomen puncture were operated on 28 pregnant women who had the indications of antenatal diagnosis. CDU was used to observe the implantation position of the fo1iaceous villis and help setting mark of the puncture point and puncture range on body surface before operation. The needle was punctured under real-time ultrasound guidance and villis were aspirated during the operation: The choice of the right time of puncture and the operation skills were emphasized in the study. Results: The CVS puncture approach should be set through CDU ob servation, which attend to avoid the surrounding blood vessels, intestinal canal and surrounding important organs. The puncture point should be chosen in a point where lobif0rmed villis distributed wider and with a larger scope. The operations were performed from 10 to13 weeks of pregnancy, with an average of 11 weeks. Among these 28 cases, 9.6 were successfully drawn materials in one time, 1 in twice and l failure, with the total ratio of achievement was 96.4%. For all the cases, fetal heart pulsating could be seen by real-time CDU observation fight after the operation, and no larger hematoma echo in the placental site occurred. Ultrasound reexamined one week after the operation, fetal heart pulsation could be found in all cases, and no abortion cases occurred after regular follow-up in 25 continued pregnant patients. Conclusion: Abdominal CVS puncture guided by CDU probe is conveniently operated, safe and available in clinic. It is an important method for antenatal diagnosis during early pregnancy. The puncture localization, skills and the time are the key points for the success in obtaining the materials. (authors)

  16. Side effects after diagnostic lumbar puncture and lumbar iohexol myelography

    International Nuclear Information System (INIS)

    Sand, T.; Stovner, L.J.; Salvesen, R.; Dale, L.

    1987-01-01

    A prospective, controlled study was performed to compare side effect incidences after lumbar iohexol myelography (n=97) and diagnostic lumbar puncture (n=85). No significant side effect incidence differences (iohexol vs. controls) were found regarding number of patients with any side effect (63 vs. 73%), headache (44 vs. 54%), nausea, dizziness, visual, auditory, or psychic symptoms. Early-onset headache occurred significantly more often in the iohexol group (16 vs 5%), while postural headache occurred most frequently after lumbar puncture (25 vs. 41%). These results suggest that apart from the slight early-onset headache, most side effets after lumbar iohexol myelography are related to the puncture per se, not to the contrast agent. (orig.)

  17. A new variant of aberrant left brachiocephalic trunk in mam: case report and literature review.

    Science.gov (United States)

    Szpinda, Michał

    2005-02-01

    Importance is placed on aberrant arteries in the radiological and surgical literature. A normal left brachiocephalic trunk is characteristic for the right aortic arch. However, an aberrant left brachiocephalic trunk arising as the last branch of the aortic arch on the left side has not yet been described in the literature. Described here is a new variant of the retro-oesophageal aberrant left brachiocephalic trunk, occasionally observed in a patient during diagnostic investigation or surgical treatment for steno-obstructive involvement of the carotid district. The triple anomaly of the left aortic arch consisted of: 1. the presence of a hypoplastic left brachiocephalic trunk behind the oesophagus, 2. the absence of a brachiocephalic trunk on the right side and 3. separate origins of the arteries on the right side, with the right common artery preceding the right subclavian artery. In front of the trachea an 8-mm prosthetic PTFE was implanted from the proximal segment of the right subclavian artery to the junction of the left common carotid and left subclavian arteries. The author demonstrates the inadequacy of auxiliary investigations to detect aberrant arteries, which may only be identified precisely intra-operatively.

  18. Technological advances and changing indications for lumbar puncture in neurological disorders

    NARCIS (Netherlands)

    Costerus, Joost M.; Brouwer, Matthijs C.; van de Beek, Diederik

    2018-01-01

    Technological advances have changed the indications for and the way in which lumbar puncture is done. Suspected CNS infection remains the most common indication for lumbar puncture, but new molecular techniques have broadened CSF analysis indications, such as the determination of neuronal

  19. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement.

    Science.gov (United States)

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2 nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically.

  20. Predisposing factors for peripheral intravenous puncture failure in children

    OpenAIRE

    Negri,Daniela Cavalcante de; Avelar,Ariane Ferreira Machado; Andreoni,Solange; Pedreira,Mavilde da Luz Gonçalvez

    2012-01-01

    OBJECTIVE: To identify predisposing factors for peripheral intravenous puncture failure in children. METHODS: Cross-sectional cohort study conducted with 335 children in a pediatric ward of a university hospital after approval of the ethics committee. The Wald Chi-squared, Prevalence Ratio (PR) and backward procedure (p≤0.05) tests were applied. RESULTS: Success of peripheral intravenous puncture was obtained in 300 (89.5%) children and failure in 35 (10.4%). The failure rates were sign...

  1. Needle puncture in rabbit functional spinal units alters rotational biomechanics.

    Science.gov (United States)

    Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D

    2015-04-01

    An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.

  2. Computation of Quantum Bound States on a Singly Punctured Two-Torus

    International Nuclear Information System (INIS)

    Kar-Tim Chan; Zainuddin Hishamuddin; Molladavoudi Saeid

    2013-01-01

    We study a quantum mechanical system on a singly punctured two-torus with bound states described by the Maass waveforms which are eigenfunctions of the hyperbolic Laplace—Beltrami operator. Since the discrete eigenvalues of the Maass cusp form are not known analytically, they are solved numerically using an adapted algorithm of Hejhal and Then to compute Maass cusp forms on the punctured two-torus. We report on the computational results of the lower lying eigenvalues for the punctured two-torus and find that they are doubly-degenerate. We also visualize the eigenstates of selected eigenvalues using GridMathematica

  3. Transbrachial artery approach for selective cerebral angiography

    International Nuclear Information System (INIS)

    Touho, Hajime; Karasawa, Jun; Shishido, Hisashi; Morisako, Toshitaka; Numazawa, Shinichi; Yamada, Keisuke; Nagai, Shigeki; Shibamoto, Kenji

    1990-01-01

    Transaxillary or transbrachial approaches to the cerebral vessels have been reported, but selective angiography of all four vessels has not been possible through one route. In this report, a new technique for selective cerebral angiography with transbrachial approach is described. One hundred and twenty three patients with cerebral infarction, vertebrobasilar insufficiency, intracerebral hemorrhage, epilepsy, or cerebral tumor were examined. Those patients consisted of 85 outpatients and 38 inpatients whose age ranged from 15 years old to 82 years old. The patients were examined via the transbrachial approach (97 cases via the right brachial, 29 cases via the left). Materials included a DSA system (Digital Fluorikon 5000, General Electric Co.), a 4 French tight J-curved Simmons 80-cm catheter, a 19-gauge extra-thin-wall Seldinger needle, and a J/Straight floppy 125-cm guide-wire. Generally, the volume of the contrast agent (300 mgI/ml iopamidol) used in the common carotid artery angiogram was 6 ml, while that used in the vertebral artery angiogram was 4 ml. If catheterization of the vertebral artery or right common carotid artery was unsuccessful, about 8 ml of the contrast agent was injected into the subclavian or branchiocephalic artery. Definitive diagnosis and a decision on proper treatment of the patients can be easily obtained, and the results were clinically satisfactory. Moreover, no complications were encountered in this study. This new technique making a transbrachial approach to the cerebral vessels using the DSA system is introduced here. Neurosurgeons can use this technique easily, and they will find that it provides them with all the information they need about the patient. (author)

  4. Vertebrocarotid collateral in extracranial carotid artery occlusions: digital subtraction angiography findings

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Kizilkilic, Osman; Tercan, Fahri; Tuerkoez, Riza; Yildirim, Tuelin

    2005-01-01

    The internal and external carotid arteries are usually considered occluded distal to a common carotid artery occlusion but some collateral vessels may provide blood keeping the internal and external carotid arteries patent distal to the occlusion. Most common communication in such a case is diversion of blood from muscular branches of the vertebral artery to occipital branch of the external carotid artery which in turn could maintain blood flow into the internal carotid artery, a condition called carotid steal. We encountered vertebrocarotid anastomoses maintaining the patency of carotid circulation in six patients. Patients were four females and two males, ages ranging from 40 to 67 (mean age: 56) years. Five of the patients had ischemic cerebral symptoms. The origin of the external carotid artery was occluded in two and the whole common carotid artery in the remaining four patients. Two patients had double steal, carotid and subclavian at the same time. There was also severe stenosis or occlusion of at least one other major extracranial cerebral artery in all the cases. This concomitant involvement of the second extracranial cerebral artery was thought to be the main reason for the development of vertebrocarotid collateral. In contrast to most of the previously published reports claiming the inadequacy of angiography when compared with colour Doppler ultrasonography, angiography finely depicted the distal patency of the carotid circulation and all the collaterals in detail in every case. Selective injection of the vertebral artery ipsilateral to the occlusion, is the key to demonstrate distal patency of the carotid circulation in cases of proximal carotid occlusion. Demonstration of patency of the distal circulation is very important because some of the patients might get benefit from a reconstructive surgery

  5. Vertebrocarotid collateral in extracranial carotid artery occlusions: digital subtraction angiography findings

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent; Kizilkilic, Osman; Tercan, Fahri; Tuerkoez, Riza; Yildirim, Tuelin

    2005-02-01

    The internal and external carotid arteries are usually considered occluded distal to a common carotid artery occlusion but some collateral vessels may provide blood keeping the internal and external carotid arteries patent distal to the occlusion. Most common communication in such a case is diversion of blood from muscular branches of the vertebral artery to occipital branch of the external carotid artery which in turn could maintain blood flow into the internal carotid artery, a condition called carotid steal. We encountered vertebrocarotid anastomoses maintaining the patency of carotid circulation in six patients. Patients were four females and two males, ages ranging from 40 to 67 (mean age: 56) years. Five of the patients had ischemic cerebral symptoms. The origin of the external carotid artery was occluded in two and the whole common carotid artery in the remaining four patients. Two patients had double steal, carotid and subclavian at the same time. There was also severe stenosis or occlusion of at least one other major extracranial cerebral artery in all the cases. This concomitant involvement of the second extracranial cerebral artery was thought to be the main reason for the development of vertebrocarotid collateral. In contrast to most of the previously published reports claiming the inadequacy of angiography when compared with colour Doppler ultrasonography, angiography finely depicted the distal patency of the carotid circulation and all the collaterals in detail in every case. Selective injection of the vertebral artery ipsilateral to the occlusion, is the key to demonstrate distal patency of the carotid circulation in cases of proximal carotid occlusion. Demonstration of patency of the distal circulation is very important because some of the patients might get benefit from a reconstructive surgery.

  6. Analysis of the indications for routine lumbar puncture and results of ...

    African Journals Online (AJOL)

    Lumbar puncture (LP) is an important diagnostic tool for investigating neurological conditions/diseases. This study was carried out to compare the indications for lumbar puncture and findings of cerebrospinal fluid examination in children admitted to Muhimbili National Hospital (MNH) in Dar-es-salaam, Tanzania and Kilifi ...

  7. The effect of lung deflation on the position and size of the subclavian vein in mechanically ventilated infants and children.

    Science.gov (United States)

    Lim, Kyung-Jee; Kim, Jin-Tae; Kim, Hee-Soo; Byon, Hyo-Jin; Lee, Soo-Kyung; Lee, Jung-Man

    2011-06-01

    If lung deflation increases the distance from the subclavian vein (SCV) to the pleura and the diameter of the vein, it might decrease the risk of pneumothorax and increase the success rate of subclavian venous cannulation. We evaluated the effect of lung deflation on the distance from the SCV to the pleura (SCV-pleura distance) and on the cross-sectional area (CSA) of the SCV in mechanically ventilated pediatric patients. Fifty patients (25 infants younger than 1 year and 25 children aged 1 to 8 years) were placed supine over a shoulder roll, and their lungs were ventilated with a tidal volume of 6 to 7 mL/kg. Lung deflation was achieved by opening the endotracheal tube to the atmosphere. The SCV-pleura distances and the SCV CSAs were measured using ultrasound at the end of inflation and 0, 30, 60, 90, and 120 seconds after lung deflation. A P value deflation. Neither the SCV-pleura distance nor the CSA showed any further increase with time. Lung deflation failed to increase the SCV-pleura distance and the CSA of the SCV. Its application is unlikely to be advantageous in avoiding pneumothorax or improving the success rate of subclavian venous cannulation.

  8. Discuss the cause and treatment of pacemaker lead dislocation and deal with

    International Nuclear Information System (INIS)

    Chen Yueguang; Zhang Dadong; Lu Jie; Yang Hui; Liu Chunyan; Zhang Wei

    2003-01-01

    Objective: To follow up the patients with pacemaker, observe the condition of pacemaker lead, to explore the cause of lead dislocation, to find out and prevent its occurrence. Methods: Summarizing the clinical data of 6 patients with pacemaker, 7 pacemaker leads with 8 time dislocation, pacemaker 2 DDDR, 2 DDD, 2 VVI. Results: Four patients were punctured from right subclavian vein, one from left subclavian vein and one from right brachiocephalic vein; four leads were dislocation in atrium and one mildly dislocation; four leads dislocation in ventricle and two mildly dislocation; There were 3 old women with 4 leads and 5 times of dislocation

  9. CT-guided puncture for direct MR-arthrography of the shoulder: Description of possible techniques

    Directory of Open Access Journals (Sweden)

    Hauth E

    2016-07-01

    Full Text Available The following report describes the possible techniques of CT-guided puncture for direct magnetic resonance (MR arthrography of the shoulder. CT-guided puncture can be regarded as an alternative technique to fluoroscopic- or ultrasound-guided puncture for MR-arthrography of the shoulder with high efficiency, low dose and extremely low complication rate.

  10. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Chan, Gabriel; Quek, Lawrence Hwee Han; Tan, Glenn Leong Wei; Pua, Uei

    2016-01-01

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  11. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Gabriel, E-mail: dr.changabriel@gmail.com; Quek, Lawrence Hwee Han, E-mail: lawrence-quek@ttsh.com.sg [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore); Tan, Glenn Leong Wei, E-mail: glenn-tan@ttsh.com.sg [Tan Tock Seng Hospital, Department of General Surgery (Singapore); Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2016-07-15

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  12. 53. Bilateral ductal stenting for nonconfluent pulmonary arteries in a newborn

    Directory of Open Access Journals (Sweden)

    K. Al Dhahri

    2016-07-01

    Full Text Available Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Limited data available for bilateral PDA stenting. Bilateral PDA stenting in nonconfluent pulmonary arteries is challenging procedure but can be considered as an option in the management of complex conditions like this. 12 days old Preterm (36 weeks gestation male baby with birth weight of 2.6 kg developed respiratory distress with severe cyanosis and desaturation upto 50%. Baby was intubated and started on Prostaglandin 0.05 mic/kg/mt. His saturation improved to 80%. Echocardiogram showed complex cyanotic heart disease, Situs ambiguous, dextrocardia, complete unbalanced AV septal defect, pulmonary atresia , nonconfluent small branch pulmonary arteries supplied by the bilateral patent ductus arteriosus (PDA from right aortic arch and all four pulmonary veins form a confluence and drain into superior vena cava(SVC through vertical vein with no obstruction. Baby was taken up for PDA stenting. descending aortogram showed right aortic arch with vertical tortuous duct to right pulmonary artery (RPA and another short duct with acute angle from left subclavian artery to left pulmonary artery (LPA . Both ducti stented with coronary stents. Vertical vein angiogram showed both lungs drain to a confluence and then to SVC via ascending vertical vein with no obstruction. After stenting lung perfusion improved and the baby was stable and maintained 80% saturation on room air. Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Our case is unique with Heterotaxy, TAPVC, Dextrocardia and double ducti. Eventhough bilateral ductal stenting is technically challenging it is successful through femoral artery approach.

  13. The clinical value of trans-vaginal ultrasound-guided puncture in the treatment of pelvic abscess

    International Nuclear Information System (INIS)

    Wang Ping; Gong Wei

    2008-01-01

    Objective: To investigate the clinical value of trans-vaginal ultrasound-guided (TVS) puncture in the treatment of pelvic abscess. Methods 30 cases with pelvic abscess were treated by transvaginal ultrasound-guided puncture. The long-dated effects were followed-up. Results: 29 cases were cured by TVS puncture. Operation was performed in 1 patient because of invalid effect. The cure rate was 97%. Conclusion: Ultrasound-guided puncture is a safe and convenient method in the treatment of pelvic abscess. (authors)

  14. Twelve months follow-up after retrograde recanalization of superficial femoral artery chronic total occlusion

    Directory of Open Access Journals (Sweden)

    Joanna Wojtasik-Bakalarz

    2017-03-01

    Full Text Available Introduction : Fifty percent of cases of peripheral artery disease are caused by chronic total occlusion (CTO of the superficial femoral artery (SFA. Ten–fifteen percent of percutaneous SFA recanalization procedures are unsuccessful. In those cases the retrograde technique can increase the success rate of the procedure, but the long-term follow-up of such procedures is still unknown. Aim : To assess the efficacy and clinical outcomes during long-term follow-up after retrograde recanalization of the SFA. Material and methods: We included patients after at least one unsuccessful percutaneous antegrade recanalization of the SFA. Patients were evaluated for the procedural and clinical follow-up of mean time 13.9 months. Results: The study included 17 patients (7 females, 10 males who underwent percutaneous retrograde recanalization of the SFA from June 2011 to June 2015. The mean age of patients was 63 ±7 years. Retrograde puncture of the distal SFA was successful in all cases. A retrograde procedure was performed immediately after antegrade failure in 4 (23.5% patients and after a previously failed attempt in 13 (76.5% patients. The procedure was successful in 15 (88.2% patients, and unsuccessful in 2 (11.8% patients. Periprocedural complications included 1 peripheral distal embolization (successfully treated with aspiration thrombectomy, 1 bleeding event from the puncture site and 7 puncture site hematomas. During follow-up the all-cause mortality rate was 5.8% (1 patient, non-cardiac death. The primary patency rate at 12 months was 88.2% and secondary patency 100%. Conclusions : The retrograde SFA puncture seems to be a safe and successful technique for CTO recanalization and is associated with a low rate of perioperative and long-term follow-up complications.

  15. Impact of Corrugated Paperboard Structure on Puncture Resistance

    Directory of Open Access Journals (Sweden)

    Vaidas Bivainis

    2015-03-01

    Full Text Available Thanks to its excellentprotective properties, lightness, a reasonable price, and ecology, corrugated paperboardis one of the most popular materials used in the production of packaging for variousproducts. During transportation or storage, packaging with goods can be exposedto the mass of other commodities, dropping from heights and transportationshock loads, which can lead to their puncture damage. Depending on the purposeand size of the packaging, the thickness, grammage, constituent paper layers,numbers of layers and type of fluting of corrugated paperboard used in itsproduction differ. A standard triangular prism, corrugated paperboard fixationplates and a universal tension-compression machine were used to investigate theimpact of corrugated paperboard structure and other parameters on the punctureresistance of the material. The investigation determines the maximum punctureload and estimates energy required to penetrate the corrugated paperboard. Itwas found that the greatest puncture resistance is demonstrated by paperboardwith a larger number of corrugating flutings and the board produced from harderpaper with a smaller amount of recycled paper. It was established that thegrammage of three-layered paperboard with two different fluting profiles has thegreatest impact on the level of static puncture energy.DOI: http://dx.doi.org/10.5755/j01.ms.21.1.5713

  16. Morphometric analysis of torso arterial anatomy with implications for resuscitative aortic occlusion.

    Science.gov (United States)

    Stannard, Adam; Morrison, Jonathan J; Sharon, Danny J; Eliason, Jonathan L; Rasmussen, Todd E

    2013-08-01

    Hemorrhage is a leading cause of death in military and civilian trauma. Despite the importance of the aorta as a site of hemorrhage control and resuscitative occlusion, detailed knowledge of its morphometry is lacking. The objective of this study was to characterize aortic morphometry in a trauma population, including quantification of distances as well as and diameters and definition of relevant aortic zones. Center line measures were made (Volume Viewer) from contrast computed tomography (CT) scans of male trauma patients (18-45 years). Aortic zones were defined based on branch arteries. Zone I includes left subclavian to celiac; Zone II includes celiac to caudal renal; Zone III includes caudal renal to aortic bifurcation. Zone lengths were calculated and correlated to a novel external measure of torso extent (symphysis pubis to sternal notch). Eighty-eight males (mean [SD], 28 [4] years) had CT scans for the study. The median (interquartile range) lengths (mm) of Zones I, II, and III were 210 mm (202-223 mm), 33 mm (28-38 mm), and 97 mm (91-103 mm), respectively. Median aortic diameters at the left subclavian, celiac, and lowest renal arteries were 21 mm (20-23 mm), 18 mm (16-19 mm), and 15 mm (14-16 mm), respectively, and the terminal aortic diameter was 14 mm (13-15 mm). The correlation of determination for descending aortic length (all zones) against torso extend was r = 0.454. This study provides a morphometric analysis of the aorta in a male population, demonstrating consistency of length and diameter while defining distinct axial zones. Findings suggest that center line aortic distances correlate with a simple, external measure of torso extent. Morphometric study of the aorta using CT data may facilitate the development and implementation of occlusion techniques to manage noncompressible torso, pelvic, and junctional femoral hemorrhage.

  17. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    Science.gov (United States)

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (Ptennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  18. Performance and complications of lumbar puncture in memory clinics : Results of the multicenter lumbar puncture feasibility study

    NARCIS (Netherlands)

    Duits, Flora H.; Martinez-Lage, Pablo; Paquet, Claire; Engelborghs, Sebastiaan; Lleo, Alberto; Hausner, Lucrezia; Molinuevo, Jose L.; Stomrud, Erik; Farotti, Lucia; Ramakers, Inez H. G. B.; Tsolaki, Magda; Skarsgard, Constance; Astrand, Ragnar; Wallin, Anders; Vyhnalek, Martin; Holmber-Clausen, Marie; Forlenza, Orestes V.; Ghezzi, Laura; Ingelsson, Martin; Hoff, Erik I.; Roks, C.M.A.A.; de Mendonca, Alexandre; Papma, Janne M.; Izagirre, Andrea; Taga, Mariko; Struyfs, Hanne; Alcolea, Daniel A.; Froelich, Lutz; Balasa, Mircea; Minthon, Lennart; Twisk, Jos W. R.; Persson, Staffan; Zetterberg, Henrik; van der Flier, Wiesje M.; Teunissen, Charlotte E.; Scheltens, Philip; Blennow, Kaj

    2016-01-01

    Introduction Lumbar puncture (LP) is increasingly performed in memory clinics. We investigated patient-acceptance of LP, incidence of and risk factors for post-LP complications in memory clinic populations. Methods We prospectively enrolled 3868 patients (50% women, age 66 ± 11 years, mini mental

  19. MR imaging with gadolinium in patients with and without post-lumbar puncture headache

    International Nuclear Information System (INIS)

    Hannerz, J.; Ericson, K.; Bro Skejoe, H.P.

    1999-01-01

    Purpose: To study frequency and extent of meningeal enhancement in patients with and without post-lumbar puncture headache (PLPH) with cerebral MR with Gd-DTPA. Material and methods: Ten consecutive patients with PLPH and 9 consecutive patients without PLPH were included in the study. Nine of the PLPH patients were reinvestigated when the PLPH was over and all non-PLPH patients during the week after the lumbar puncture. Results: Eight of the 9 patients with PLPH showed more enhancement of meningeal structures during PLPH than when PLPH had disappeared. The differences were slight in 5, more marked in 2, and pronounced in 1 patient. The 9th patient showed no change at all. In the 9 patients without PLPH, there was mainly slight enhancement before lumbar puncture and no change in enhancement after lumbar puncture as compared with before. Conclusion: PLPH is related to increased Gd-DTPA enhancement of the meninges, although the increase in enhancement during PLPH is minor in most cases. Pronounced enhancement of the meninges after lumbar puncture may predict long duration of the PLPH. (orig.)

  20. A tetrad of bicuspid aortic valve association: A single-stage repair

    Science.gov (United States)

    Barik, Ramachandra; Patnaik, A. N.; Mishra, Ramesh C.; Kumari, N. Rama; Gulati, A. S.

    2012-01-01

    We report a 27 years old male who presented with a combination of both congenital and acquired cardiac defects. This syndrome complex includes congenital bicuspid aortic valve, Seller's grade II aortic regurgitation, juxta- subclavian coarctation, stenosis of ostium of left subclavian artery and ruptured sinus of Valsalva aneurysm without any evidence of infective endocarditis. This type of constellation is extremely rare. Neither coarctation of aorta with left subclavian artery stenosis nor the rupture of sinus Valsalva had a favorable pathology for percutaneus intervention. Taking account into morbidity associated with repeated surgery and anesthesia patient underwent a single stage surgical repair of both the defects by two surgical incisions. The approaches include median sternotomy for rupture of sinus of Valsalva and lateral thoracotomy for coarctation with left subclavian artery stenosis. The surgery was uneventful. After three months follow up echocardiography showed mild residual gradient across the repaired coarctation segment, mild aortic regurgitation and no residual left to right shunt. This patient is under follow up. This is an extremely rare case of single stage successful repair of coarctation and rupture of sinus of Valsalva associated with congenital bicuspid aortic valve. PMID:22629035

  1. Experimental analysis of Kevlar modification for TRUPACT-I puncture panels

    International Nuclear Information System (INIS)

    Longenbaugh, R.S.; Joseph, B.J.

    1987-05-01

    The Kevlar Test Services was initiated to determine the maximum failure force and the energy-absorbing capability of puncture panels consisting of 16, 20, and 24 layers of 3000-denier 4 x 4 basket weave Kevlar-29, bonded to a 3.41 mm 304 annealed stainless steel puncture plate. Results of these tests were compared to the TRUPACT-1 Unit-0 drop test results to determine if the existing puncture panel configuration of TRUPACT-1 could be reduced. The data indicate for 24 layers of Kevlar, the panels failed at loads greater than those recorded in the TRUPACT-1, Unit 0 tests. Energy absorbed by the 24-layer Kevlar panels was 53% greater than that measured in the TRUPACT-1, Unit 0 test. Thermal performance of 20-layer Kevlar panels was measured in a conservative test environment and exceeded the design specifications

  2. Percutaneous Direct Puncture Embolization with N-butyl-cyanoacrylate for High-flow Priapism

    Energy Technology Data Exchange (ETDEWEB)

    Tokue, Hiroyuki, E-mail: tokue@s2.dion.ne.jp; Shibuya, Kei [Gunma University Hospital, Department of Diagnostic and Interventional Radiology (Japan); Ueno, Hiroyuki [Isesaki Municipal Hospital, Department of Radiology (Japan); Tokue, Azusa; Tsushima, Yoshito [Gunma University Hospital, Department of Diagnostic and Interventional Radiology (Japan)

    2016-09-15

    There are many treatment options in high-flow priapism. Those mentioned most often are watchful waiting, Doppler-guided compression, endovascular highly selective embolization, and surgery. We present a case of high-flow priapism in a 57-year-old man treated by percutaneous direct puncture embolization of a post-traumatic left cavernosal arteriovenous fistula using N-butyl-cyanoacrylate. Erectile function was preserved during a 12-month follow-up. No patients with percutaneous direct puncture embolization for high-flow priapism have been reported previously. Percutaneous direct puncture embolization is a potentially useful and safe method for management of high-flow priapism.

  3. PROLONGED RADIAL ARTERY SPASM IN THE CATHETERIZATION LABORATORY - RELIEF BY PHARMACOLOGICAL INTERVENTION

    Directory of Open Access Journals (Sweden)

    Krishna Kumar

    2010-11-01

    Full Text Available Radial spasm is often very prolonged and painful to the patient. Here, we describe a novel way to deal with the same. The total spasm lasted over 4 hours. A 3.4 6 JR catheter was introduced via the femoral route and papav arine one ampoule was injected directly into the right subclavian artery. After about 10 min we were able to pull out the radial catheter. Radial angiography is a simple procedure with reportedly less complications 1,2. How ever ,it has one major complication radial spasm. We describe here a patient with radial spasm that persisted for more than 2 hours and how we dealt with it.

  4. Dissection of descending aorta treated by stent-graft implantation in a patient with Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Marat A. Aripov

    2017-04-01

    Full Text Available This report describes a 32 years old patient with Marfan syndrome and hypertension. David`s procedure was performed to the patient three months before due to dissection of the ascending thoracic aorta. Computer tomography scan showed DeBakey type III dissection of aorta beginning from left subclavian artery with transition to the ostium of the celiac trunk and proximal part of the left common iliac artery. Stent-grafts in the descending thoracic aorta with overlapping of left subclavian artery were implanted to the patient with Marfan syndrome. Patient was discharged and no complications recorded at 6th month follow-up.

  5. Mechanical deformation and glycosaminoglycan content changes in a rabbit annular puncture disc degeneration model.

    Science.gov (United States)

    Chan, Deva D; Khan, Safdar N; Ye, Xiaojing; Curtiss, Shane B; Gupta, Munish C; Klineberg, Eric O; Neu, Corey P

    2011-08-15

    Evaluation of degenerated intervertebral discs from a rabbit annular puncture model by using specialized magnetic resonance imaging (MRI) techniques, including displacement encoding with stimulated echoes and a fast-spin echo (DENSE-FSE) acquisition and delayed gadolinium-enhanced MRI of cartilage (dGEMRIC). To evaluate a rabbit disc degeneration model by using various MRI techniques. To determine the displacements and strains, spin-lattice relaxation time (T1), and glycosaminoglycan (GAG) distribution of degenerated discs as compared to normal and adjacent level discs. Annular puncture of the intervertebral disc produces disc degeneration in rabbits. DENSE-FSE has been previously demonstrated in articular cartilage for the measurement of soft tissue displacements and strains. MRI also can measure the T1 of tissue, and dGEMRIC can quantify GAG concentration in cartilage. METHODS.: In eight New Zealand white rabbits, the annulus fibrosis of a lumbar disc was punctured. After 4 weeks, the punctured and cranially adjacent motion segments were isolated for MRI and histology. MRI was used to estimate the disc volume and map T1. DENSE-FSE was used to determine displacements for the estimation of strains. dGEMRIC was then used to determine GAG distributions. Histology and standard MRI indicated degeneration in punctured discs. Disc volume increased significantly at 4 weeks after the puncture. Displacement of the nucleus pulposus was distinct from that of the annulus fibrosis in most untreated discs but not in punctured discs. T1 was significantly higher and GAG concentration significantly lower in punctured discs compared with untreated adjacent level discs. Noninvasive and quantitative MRI techniques can be used to evaluate the mechanical and biochemical changes that occur with animal models of disc degeneration. DENSE-FSE, dGEMRIC, and similar techniques have potential for evaluating the progression of disc degeneration and the efficacy of treatments.

  6. Use of inelastic analysis to determine the response of packages to puncture accidents

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Ludwigsen, J.S.

    1996-01-01

    The accurate analytical determination of the response of radioactive material transportation packages to the hypothetical puncture accident requires inelastic analysis techniques. Use of this improved analysis method recudes the reliance on empirical and approximate methods to determine the safety for puncture accidents. This paper will discuss how inelastic analysis techniques can be used to determine the stresses, strains and deformations resulting from puncture accidents for thin skin materials with different backing materials. A method will be discussed to assure safety for all of these types of packages

  7. Is guidewire exchange a better approach for subclavian vein re-catheterization for chronic hemodialysis patients?

    Science.gov (United States)

    Hou, Shaw-Min; Chou, Po-Ching; Huang, Chi-Hung; Chin, Chih-Hui; Wang, Pa-Chun; Chen, Ya-Hui

    2006-01-01

    The objectives of this study were to compare outcomes and survival rates of subclavian vein re-catheterization through guide wire exchange (GWE) or de novo insertion (DN). The study was conducted in a retrospective manner. Medical records of 36 patients who received percutaneous subclavian vein re-catheterization for hemodialysis in our institution during the period from April 1, 2001 to September 30, 2004 were reviewed. All patients had at least 2 catheter insertions records in our institute. Incidences of adverse events (infection, thrombosis) were compared between GWE and DN groups using x2 test. Predictors for adverse event occurrences were analyzed using logistic regression models. Cox proportional hazard model was used to investigate the predictors for adverse event-free catheter days. Kaplan-Meire survival curves were computed and compared using log rank test. Information were generated from 98 catheters (41 from DN, 57 from GWE groups). The average catheter usage was 2.8+/-0.9 devices per patient and the mean catheter-indwelling-day was 125.4+/-129.5 days in this cohort. We found GWE group had significantly lower thrombosis rate (49.1% vs. 85.4% for DN group, Prates for GWE were > or =30 days, 85.4%; > or =60 days, 75.5%; > or =90 days, 64.5%; > or =180 days, 44.3%. The actuarial survival rates for DN were > or =30 days, 70.7%; > or =60 days, 58.5%; > or =90 days, 34.2%; > or =180 days, 18.4%. GWE group catheters had significantly higher catheter survival rates (P=0.0009). Mahukar catheter (hazard ratio 0.514, P=0.03), non-shock (hazard ratio 3.358, P=0.04), and older age (hazard ratio 0.958, P=0.026) were predictors of adverse event-free remaining catheter days. We suggest that GWE might be a favorable option over DN insertion when revised subclavian vein catheterization is inevitable. GWE can be performed repeatedly without compromising catheter outcomes.

  8. Endovascular Repair of Acute Symptomatic Pararenal Aortic Aneurysm With Three Chimney and One Periscope Graft for Complete Visceral Artery Revascularization

    International Nuclear Information System (INIS)

    Brechtel, Klaus; Ketelsen, Dominik; Endisch, Andrea; Heller, Stephan; Heuschmid, Martin; Stock, Ulrich A.; Kalender, Guenay

    2012-01-01

    PurposeTo describe a modified endovascular technique for complete revascularization of visceral and renal arteries in symptomatic pararenal aortic aneurysm (PRAA).TechniqueArterial access was surgically established in both common femoral arteries (CFAs) and the left subclavian artery (LSA). Revascularization of the left renal artery, the celiac trunk, and the superior mesenteric artery was performed through one single sheath via the LSA. Suitable covered stents were put in the aortic branches but not deployed. The right renal artery was accessed over the left CFA. Due to the longitudinal extension of the presented aneurysm two stent-grafts were introduced via the right CFA. After deploying the aortic stent-grafts, all covered stents in the side branches were deployed consecutively with a minimum overlap of 5 mm over the cranial and caudal stent-graft edges. Simultaneous ballooning was performed to fully expand all stent-grafts and warranty patency. Conclusion: This is the first report in the literature of chimney grafting in PRAA for complete revascularization of visceral and renal branches by using more than two covered stents introduced from one side through one single sheath. However this technique is modified, it should be used only in bailout situations when branched stent-grafts are not available and/or surgery is not suitable.

  9. The natural history of pedal puncture wounds in diabetics: a cross-sectional survey

    Directory of Open Access Journals (Sweden)

    East Jeffrey M

    2011-10-01

    Full Text Available Abstract Background Surgeons usually witness only the limb-threatening stages of infected, closed pedal puncture wounds in diabetics. Given that this catastrophic outcome often represents failure of conservative management of pre-infected wounds, some suggest consideration of invasive intervention (coring or laying-open for pre-infected wounds in hope of preventing contamination from evolving into infection, there being no evidence based guidelines. However, an invasive pre-emptive approach is only justifiable if the probability of progression to catastrophic infection is very high. Literature search revealed no prior studies on the natural history of closed pedal puncture wounds in diabetics. Methods A survey was conducted via an interviewer-administered questionnaire on 198 adult diabetics resident in the parish of St. James, Jamaica. The sample was selected using a purposive technique designed to mirror the social gradient and residential distribution of the target population and is twice the number needed to detect a prevalence of puncture wounds of 14% with a range of 7-21% in a random sample of the estimated adult diabetic population. Results The prevalence of a history of at least one closed pedal puncture wound since diagnosis of diabetes was 25.8% (CI; 19.6-31.9%. The only modifiable variable associated at the 5% level of significance with risk of pedal puncture wound, after adjustment by multivariable logistic regression, was site of interview/paying status, a variable substantially reflective of income more so than quality-of-care. Of 77 reported episodes of closed pedal puncture wound among 51 participants, 45.4% healed without medical intervention, 27.3% healed after non-surgical treatment by a doctor and 27.3% required surgical intervention ranging from debridement to below-knee amputation. Anesthetic foot (failure to feel the puncture and sole of the forefoot as site of puncture were the variables significantly associated with

  10. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO System: A Cadaver Study.

    Directory of Open Access Journals (Sweden)

    Guoxin Fan

    Full Text Available Percutaneous transforaminal endoscopic discectomy (PTED usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence.This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO system in puncture reduction of PTED.Cadaver study.Comparative groups.HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A. Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B. On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C.At L4/L5 level, there was significant difference in puncture times between Group A and Group B (P0.05. There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05.Small-sample preclinical study.HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127.

  11. Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wybranski, Christian, E-mail: Christian.Wybranski@uk-koeln.de [University Hospital of Cologne, Department of Diagnostic and Interventional Radiology (Germany); Pech, Maciej [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine (Germany); Lux, Anke [Otto-von-Guericke University Medical School, Institute of Biometry and Medical Informatics (Germany); Ricke, Jens; Fischbach, Frank; Fischbach, Katharina [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine (Germany)

    2017-06-15

    ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.

  12. Endovascular treatment of penetrating arterial trauma with stent grafts.

    Science.gov (United States)

    Biagioni, Rodrigo Bruno; Burihan, Marcelo Calil; Nasser, Felipe; Biagioni, Luisa Ciucci; Ingrund, José Carlos

    2018-02-01

    The endovascular management of arterial injuries has resulted in reduced operating time, blood loss, hospital mortality, lower incidence of sepsis, and decrease in mortality rates. For penetrating trauma, however, the benefits of endovascular therapy are questionable. Data were obtained by retrospective analysis of electronic medical records. All patients with vascular trauma seeking care at our institution from January 2010 to December 2015 were reviewed. A total of 223 vascular trauma patients were enrolled. Of these, 18 patients (8 %) were treated with endovascular techniques. The data related to clinical presentation, patient characteristics, technical aspects of the treatment, and follow-up were analysed. The mean patient age was 35.4 ± 17.8 years, 94 % were male. The mean injury severity score was 10.4 ± 2.5. The most commonly observed trauma mechanism was a gunshot in 10 cases (55 %), followed by lesions provoked by arterial catheter misplacement in five cases (27 %), and stab wounds in three cases (16.6 %). The main injury site was the subclavian artery, accounting for eight cases (44 %), followed by the superficial femoral artery and the tibiofibular trunk in two cases, respectively (18 %). The anterior tibial, fibular artery, axillary, common carotid, superior mesenteric, and profunda femoris were each affected once. Arteriovenous fistula was detected in nine cases (50 %), pseudoaneurysms in nine cases (50 %), and short occlusion in two cases (11 %). The mean follow-up duration was 753 days. The primary patency rate was 92.3 and 61.5 % after one and two years, respectively. The survival rate was 94.4 % after one and two years. Infection of the stents or limb amputations were not identified at follow-up. The endovascular treatment of penetrating arterial injuries with covered stents is feasible. However, the criteria used to choose the best method must be individualized.

  13. A conservative approach to a thoracic duct injury caused by left subclavian vein catheterization

    OpenAIRE

    Vedran Premuzic; Ranko Smiljanic; Drazen Perkov

    2018-01-01

    Thoracic duct injury is a rare complication of left subclavian vein catheterization. A significant injury could lead to chylothorax, a condition with high mortality rate if not treated. It is diagnosed with lymphography or by laboratory tests of pleural fluid aspirate. A 51 year old Caucasian male with a history of unregulated hypertension presented to our Emergency department (ED) with anginous symptoms and increased serum creatinine level. After the placement of a temporary central venous c...

  14. Testing and analysis to determine the shell thickness required to prevent puncture

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Radloff, H.D.; Eifert, E.J.

    1998-05-01

    Type B radioactive material packages are required to withstand a hypothetical puncture accident of a free fall from a height of one meter onto a 15 cm diameter mild steel puncture probe. For many packages it is desirable to have this accident event not result in puncture or tearing of the outer shell of the package. The wall thickness necessary to prevent this has historically been determined by test or the use of empirical relations. This technique generally results in overly conservative designs, but the degree of conservatism is uncertain. The use of modem finite element codes to determine package response to puncture accidents can result in designs that are both safe and economical. The work reported in this paper is aimed at developing a method to analytically determine the wall thickness required to prevent puncture. For designers and regulators to have confidence in this analytical method, however, it must be benchmarked against test results. A series of tests has been conducted with differing shell thicknesses, shell materials of mild steel and stainless steel, and shell backing materials of lead, foam, and air. The results of these tests have been compared with pre-test analytical predictions of the response obtained from the nonlinear transient dynamic finite element program PRONTO-2D. From this comparison it can be seen that the finite element method can accurately predict the response of packages to puncture accidents. This implies that an analytical technique based on the finite element method can be used to design packages having known response and margin of safety against tearing of the outer shell. In addition, the analytical technique can accurately predict the deformed shape of the package following the test. This may be important for subsequent calculations, such as external dose and heat input during a thermal event

  15. C6 plate puncture testing report.

    Energy Technology Data Exchange (ETDEWEB)

    Vangoethem, Douglas J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Cordova, Theresa Elena [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Reu, Phillip L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-04-01

    There are numerous scenarios where critical systems could be subject to penetration by projectiles or fixed objects (e.g., collision, natural disaster, act of terrorism, etc.). It is desired to use computational models to examine these scenarios and make risk-informed decisions; however, modeling of material failure is an active area of research, and new models must be validated with experimental data. The purpose of this report is to document the experimental work performed from FY07 through FY08 on the Campaign Six Plate Puncture project. The goal of this project was to acquire experimental data on the puncture and penetration of metal plates for use in model validation. Of particular interest is the PLH failure model also known as the multilinear line segment model. A significant amount of data that will be useful for the verification and validation of computational models of ductile failure were collected during this project were collected and documented herein; however, much more work remains to be performed, collecting additional experimental data that will further the task of model verification.

  16. Laser puncture therapy of nervous system disorders

    Energy Technology Data Exchange (ETDEWEB)

    Anishchenko, G.; Kochetkov, V.

    1984-08-29

    The authors discuss experience with treatment of nervous system disorders by means of laser-puncture therapy. Commenting on the background of the selection of this type of treatment, they explain that once researchers determined the biological action of laser light on specific nerve receptors of the skin, development of laser apparatus capable of concentrating the beam in the millimeter band was undertaken. The devices that are being used for laser-puncture are said to operate in the red helium-neon band of light. The authors identify beam parameters that have been selected for different groups of acupuncture points of the skin, and the courses of treatment (in seconds of radiation) and their time intervals. They go on to discuss the results of treatment of over 800 patients categorized in a group with disorders of the peripheral nervous system and a second group with disorders of the central nervous system.

  17. Clinical use of femoral artery hemostasis sticking after interventional procedure via femoral artery access

    International Nuclear Information System (INIS)

    Zhu Zhongsheng; Chen Shaoliang; Ye Fei; Zhang Junjie; Zhou Jie; Tian Nailiang; Lin Song; Liu Zhizhong; Xiao Pingxi; Qu Hong

    2010-01-01

    Objective: To observe the clinical effect of the use of femoral artery hemostasis sticking V+PAD after the interventional procedure via femoral artery access. Methods: By using random permutation list 80 patients, who decided to receive coronary angiography and percutaneous transluminal coronary angioplasty, were randomly selected. Of the 80 patients, hemostasis sticking V + PAD was employed in 40 patients with even numbers (trial group), only manual compression was adopted to stop bleeding in another 40 patients with odd numbers (control group). All the patients were informed about this trial and had to sign a consent letter. The pressure time, the treatment method of access site after hemostasis, the posture in bed, the immobilization time, the comfort degree of patients, the complications of access site prior to discharge, etc. were observed and the results were compared between two groups. Results: There was no significant difference between two groups as respect to age, gender ratios,activated clotting time (ACT) value and blood pressure. However, significantly difference in the compression time and bed rest time existed between the two groups. The compression time in trial group and control group was (7.9 ± 0.5) min and (19.8 ± 5.1) min respectively (P<0.01), while the bed rest time in trial group and control group was (6.1 ± 5.0) hours and (23.9 ± 0.2) hours respectively (P<0.01). All patients in trial group was supine in bed with the head side of the bed raised at 30 degree immediately after the procedure, and the head side of the bed was further raised to 90 degree one hour later. The puncture site was bandaged with conventional compression and immobilization was not employed. Patients could lie in bed with free posture and the patient's comfort degree was greatly improved. During hospitalization no complications related to puncture site occurred in all patients except one obese woman in trial group who developed pseudoaneurysm. Conclusion: Femoral

  18. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO) System: A Cadaver Study.

    Science.gov (United States)

    Fan, Guoxin; Guan, Xiaofei; Sun, Qi; Hu, Annan; Zhu, Yanjie; Gu, Guangfei; Zhang, Hailong; He, Shisheng

    2015-01-01

    Percutaneous transforaminal endoscopic discectomy (PTED) usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence. This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO) system in puncture reduction of PTED. Cadaver study. Comparative groups. HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A). Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B). On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C). At L4/L5 level, there was significant difference in puncture times between Group A and Group B (PHELLO system reduced 39%-45% radiation dosage when comparing Group A and Group B, but there was no significant difference in radiation exposure between Group A and Group C whatever at L4/L5 level or L5/S1 level (P>0.05). There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05). Small-sample preclinical study. HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127).

  19. Laparoscopic Removal of a Large Ovarian Mass Utilizing Planned Trocar Puncture

    OpenAIRE

    Stitely, Michael L.

    2012-01-01

    Background: Large cystic ovarian masses pose technical challenges to the laparoscopic surgeon. Removing large, potentially malignant specimens must be done with care to avoid the leakage of cyst fluid into the abdominal cavity. Case: We present the case of a large ovarian cystic mass treated laparoscopically with intentional trocar puncture of the mass to drain and remove the mass. Discussion: Large cystic ovarian masses can be removed laparoscopically with intentional trocar puncture of the ...

  20. Immediate arterial hemostasis after cardiac catheterization: initial experience with a new puncture closure device.

    Science.gov (United States)

    Aker, U T; Kensey, K R; Heuser, R R; Sandza, J G; Kussmaul, W G

    1994-03-01

    A novel device for obtaining arterial hemostasis after invasive procedures was tested in 30 patients undergoing diagnostic catheterization (26 patients) or coronary angioplasty (4 patients). The device is deployed through an arterial sheath and forms a positive mechanical seal both inside and outside the defect in the arterial wall. The components are all bioabsorbable. Thirteen patients received a heparin bolus during the catheterization procedure. The activated clotting time recorded in 15 patients just prior to device deployment averaged 264 sec. 29 of 32 attempted device deployments were successful (91%); and the remaining 3 devices pulled completely out as called for by design in the event of incomplete deployment. Twenty-nine patients ultimately achieved successful hemostasis using the device, with the other patient receiving manual hemostasis. Of these 29, hemostasis was immediate and complete in 19 patients. Light digital pressure was required in another 8 patients for less than 5 min. There was minor delayed bleeding requiring supplemental light pressure in several cases. A total of 11 patients required supplemental pressure in addition to the hemostasis device. The use of bolus heparin was significantly (P = 0.05, Fisher's exact test) related to the requirement for supplemental pressure. Three patients developed hematomas, one of which was present prior to device deployment. The other two patients had received bolus heparin. No patient required transfusion or surgical repair. There was no change in the ankle/brachial systolic blood pressure index after device deployment or at late (30-60 day) follow-up. Ultrasound studies revealed no significant pathology relative to the device.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Validation of a novel cost effective easy to produce and durable in vitro model for kidney-puncture and PNL-Simulation.

    Science.gov (United States)

    Klein, Jan Thorsten; Rassweiler, Jens; Rassweiler-Seyfried, Marie-Claire Charlotte

    2018-03-29

    Nephrolithiasis is one of the most common diseases in urology. According to the EAU Guidelines, a percutaneous nephrolitholapaxy (PNL) is recommended when treating a kidney stone >2 cm. Nowadays PNL is performed even for smaller stones (PNL is the puncture of the planned site. PNL-novice surgeons need to practice this step in a safe environment with an ideal training model. We developed and evaluated a new, easy to produce, in-vitro model for the training of the freehand puncture of the kidney. Porcine kidneys with ureters were embedded in ballistic gel. Food coloring and preservative agent were added. We used the standard imaging modalities of X-ray and ultrasound to validate the training model. An additional new technique, the iPAD guided puncture, was evaluated. Five novices and three experts conducted 12 punctures for each imaging technique. Puncture time, radiation dose, and number of attempts to a successful puncture were measured. Mann-Whitney-U, Kruskal-Wallis, and U-Tests were used for statistical analyses. The sonographic guided puncture is slightly but not significantly faster than the fluoroscopic guided puncture and the iPAD assisted puncture. Similarly, the most experienced surgeon's time for a successful puncture was slightly less than that of the residents, and the experienced surgeons needed the least attempts to perform a successful puncture. In terms of radiation exposure, the residents had a significant reduction of radiation exposure compared to the experienced surgeons. The newly developed ballistic gel kidney-puncture model is a good training tool for a variety of kidney puncture techniques, with good content, construct, and face validity.

  2. Percutaneous hepatic arterial catheterization for infusion chemotherapy in treatment of primary hepatoma

    International Nuclear Information System (INIS)

    Juhn, Jae Ryang; Chang, Jae Yong; Cha, Seong Sook; Han, Sang Suk; Bae, Cheol; Kim, Sung Rok; Chae, Yoo Soon

    1984-01-01

    Chemotherapy offers palliative treatment to patient with advanced nonresectable hepatoma. The usefulness of systemic chemotherapy is limited because of serious side reaction and low concentration of drug at tumor. But this problem may be overcome by intraarterial infusion. Nonsurgical percutaneous hepatic arterial catheterization was done in 21 patients with primary hepatoma, and infusion chemotherapy was done in 19 patients who were successful in catheterization. The results were as follows: 1. Selective catheterization of hepatic artery proper, common hepatic artery, and celiac artery were successful in 4, 9 and 4 patients respectively. The success rate of selective catheterization is 80.9% including celiac artery among 21 patients with hepatoma. 2. Simple catheterization method was applied in 14 patients, and catheter exchange and Loop methods were applied in 2 and 1 patient respectively. 3. Complication related to catheterization, such as infection and bleeding on punctured site, intimal injury and dislodgement of catheter were not serious. 4. Drugs were well tolerated without serious toxicity or complication. 5. 3 patients showed objective response and median survival time of treated patients is 2.5 months.

  3. Bilateral subdural hematoma secondary to accidental dural puncture

    Directory of Open Access Journals (Sweden)

    Sofía Ramírez

    2015-07-01

    Full Text Available We report the case of a 25-year-old woman, who received epidural analgesia for labor pain and subsequently presented post-dural puncture headache. Conservative treatment was applied and epidural blood patch was performed. In the absence of clinical improvement and due to changes in the postural component of the headache, a brain imaging test was performed showing a bilateral subdural hematoma.The post-dural puncture headache is relatively common, but the lack of response to established medical treatment as well as the change in its characteristics and the presence of neurological deficit, should raise the suspicion of a subdural hematoma, which although is rare, can be lethal if not diagnosed and treated at the right time. Resumo: Apresentamos o caso clínico de uma paciente de 25 anos de idade, na qual uma técnica peridural foi realizada durante o trabalho de parto e posteriormente apresentou cefaleia com características de cefaleia pós-punção dural. Foi iniciado tratamento conservador e tampão de sangue peridural. Devido a ausência de melhora clínica e à mudança do componente postural da cefaleia, decidiu-se realizar um exame de imagem cerebral que demostrou a presença de hematoma subdural bilateral.A cefaleia pós-punção dural é relativamente frequente, mas a falta de resposta ao tratamento médico instaurado, assim como a mudança em suas características e a presença de foco neurológico, devem levantar a suspeita de presença de um hematoma subdural que, embora infrequente, pode chegar a ser devastador se não for diagnosticado e tratado oportunamente. Keywords: Accidental dural puncture, Epidural analgesia, Post-dural puncture headache, Subdural hematoma, Epidural blood patch, Palavras chave: Dura-Máter, Analgesia epidural, Cefaleia pós-punção dural, Hematoma subdural, Placa de sangue epidural

  4. The effect of second-stage pushing and body mass index on postdural puncture headache.

    Science.gov (United States)

    Franz, Amber M; Jia, Shawn Y; Bahnson, Henry T; Goel, Akash; Habib, Ashraf S

    2017-02-01

    To explore how pushing during labor and body mass index affect the development of postdural puncture headache in parturients who experienced dural puncture with Tuohy needles. Retrospective cohort. Obstetric ward and operating rooms at a university-affiliated hospital. One hundred ninety parturients who had witnessed dural puncture with 17 or 18 gauge Tuohy needles from 1999-2014. Patients were categorized by pushing status and body mass index (kg/m 2 ): nonobese push, women who pushed during labor had increased risk of postdural puncture headache (odds ratio [OR], 2.1 [1.1-4.0]; P=.02), more days of headache (P=.02), and increased epidural blood patch placement (P=.02). Super obese patients were less likely to develop headache compared with nonobese (OR, 0.33 [0.13-0.85]; P=.02), obese (OR, 0.37 [0.14-0.98]; P=.045], and morbidly obese patients (OR, 0.20 [0.05-0.68]; Ppushing (OR, 0.57 [0.29-1.10]; P=.096) and super obesity (OR, 0.41 [0.16-1.02]; P=.056] were no longer significantly associated with reduced risk of postdural puncture headache. Parturients who did not push before delivery and parturients with body mass index ≥50kg/m 2 were less likely to develop postdural puncture headache in a univariate analysis. Similar trends were demonstrated in a multivariate model, but were no longer statistically significant. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Development of puncture resistance tire tube; Nirinsha no taipankusei kojo cube no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Yamagiwa, T; Nakayama, K; Kiyota, S; Tanaka, A [Honda R and D Co. Ltd., Tokyo (Japan); Makisaka, N

    1997-10-01

    A new tire tube with a puncture resistance function was developed. The tube is a two-chamber structure having an air chamber and a liquid chamber, and the liquid chamber at the crown-side half of the tube is filled with an anti-puncture sealant during a manufacturing process. In a market test, it was confirmed that the number of puncture cases were reduced by 90 % in comparison with conventional tire tubes by using the newly developed tube. This paper describes the structure of the tube and the characteristics of the tube rubber, and the manufacturing process and durability of the tube. 3 refs., 17 figs.

  6. Starclose SE® hemostasis after 6F direct antegrade superficial femoral artery access distal to the femoral head for peripheral endovascular procedures in obese patients.

    Science.gov (United States)

    Spiliopoulos, Stavros; Kitrou, Panagiotis; Christeas, Nikolaos; Karnabatidis, Dimitris

    2016-01-01

    Direct superficial femoral artery (SFA) antegrade puncture is a valid alternative to common femoral artery (CFA) access for peripheral vascular interventions. Data investigating vascular closure device (VCD) hemostasis of distant SFA 6F access are limited. We aimed to investigate the safety and effectiveness of the Starclose SE® VCD for hemostasis, following direct 6F antegrade SFA access distal to the femoral head. This prospective, single-center study included patients who were not suitable for CFA puncture and were scheduled to undergo peripheral endovascular interventions using direct antegrade SFA 6F access, at least 2 cm below the inferior edge of femoral head. Hemostasis was obtained with the Starclose SE® VCD (Abbott Laboratories). Primary endpoints were successful hemostasis rate and periprocedural (30-day) major complication rate. Secondary endpoint was the rate of minor complications. Clinical and Doppler ultrasound follow-up was performed at discharge and at one month. Between September 2014 and August 2015, a total of 30 patients (21 male; 70.0%) with a mean body mass index of 41.2 kg/m2 were enrolled. Mean age was 72±9 years (range, 67-88 years). Most patients suffered from critical limb ischemia (87.1%) and diabetes (61.3%). Calcifications were present in eight cases (26.6%). Reason for direct SFA puncture was obesity (100%). Successful hemostasis was achieved in 100% of the cases. No major complications were noted after one-month follow-up. Minor complications included two <5 cm hematomas (6.6%) not necessitating treatment. In this prospective study, Starclose SE® VCD was safe and effective for hemostasis of antegrade direct SFA puncture. Uncomplicated hemostasis was achieved even in cases of puncturing 2 to 7 cm below the inferior edge of the femoral head.

  7. Ultrasound-guided catheterization of the left subclavian vein without recognition of persistent left superior vena cava

    OpenAIRE

    Park, Sun Young; Yoo, Jae Hwa; Kim, Mun Gyu; Kim, Sang Ho; Park, Byoung-Won; Oh, Hong Chul; Kim, Hojoon

    2017-01-01

    Abstract Rationale: A persistent left superior vena cava (PLSVC) is rare, but the most common thoracic venous anomaly. We report a case of PLSVC unrecognized during left subclavian vein catheterization using real-time ultrasound-guided supraclavicular approach. Patient concerns: A 79-year-old man with history of hypertension presented with traumatic subdural hemorrhage, subarachnoid hemorrhage, and epidural hemorrhage. Before the operation, a central venous catheter (CVC) was placed into the ...

  8. Fabrication of Bonding-Type Hollow Microneedle Array by Injection Molding and Evaluation of its Puncture Characteristics

    Science.gov (United States)

    Ogai, Noriyuki; Sugimura, Ryo; Tamaru, Takuya; Takiguchi, Yoshihiro

    A microneedle array which consists from small needles compared to a conventional metal injection needle is expected as a low invasive transdermal medical treatment device, and many fabrication approach have been conducted. In this study, we fabricated plastic hollow microneedle array by a fabrication method based on the combination of injection molding, bonding and assembly techniques. To evaluate puncture characteristics of the fabricated needle, we measured a puncture force to silicone rubber by experimental equipment using loadcell and automatic stage. Furthermore, we propose and demonstrate a new method to measure actual punctured depth from punctured trace on the needle surface modified by O2 plasma treatment.

  9. Outpatient angioplasty and stenting facilitated by percutaneous arterial suture closure devices

    International Nuclear Information System (INIS)

    Wilde, N.T.; Bungay, P.; Johnson, L.; Asquith, J.; Butterfield, J.S.; Ashleigh, R.J.

    2006-01-01

    Aim: To review our practice of outpatient percutaneous vascular interventions facilitated by an arterial suture device. Materials and methods: A retrospective review of all patients attending this tertiary centre for iliac or femoral intervention was undertaken between February 2001 and December 2004. All patients who underwent angioplasty or stenting had their puncture sites closed using a Perclose suture. Patients were kept flat for 15 min and allowed to fully mobilize at 60 min. Puncture sites were scored for visible bruising, haematoma and pain at discharge and on outpatient follow-up. Patient preference for future outpatient treatment was assessed. Results: Fifty-seven outpatients underwent 81 punctures. Forty-eight (84%) patients underwent iliac angioplasty; of those 42% underwent stent placement. Six patients (10%) required inpatient admission, five secondary to failed suture deployment. One patient had a non-closer-related puncture site intimal flap occlusion successfully repaired at surgery. Fifty-one (90%) patients discharged with a mean time of 157 min (60-280 min). Forty-six (92%) patients had no visible bruising or palpable haematoma on discharge. No patient had a haematoma greater than 2.5 cm. No discharged patient required readmission. Thirty percent reported a moderate to severe groin pain score (2-5/5) at discharge, increasing to 40% at follow-up. Forty-seven (98%) of the 48 patients, who expressed a preference, would be happy to undergo outpatient treatment again. Conclusion: Outpatient treatment is feasible, well tolerated and preferable to patients, but 10% will require inpatient admission. A planned post-procedure analgesia regimen or advice should be considered

  10. Outpatient angioplasty and stenting facilitated by percutaneous arterial suture closure devices

    Energy Technology Data Exchange (ETDEWEB)

    Wilde, N.T. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom); Bungay, P. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom); Johnson, L. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom); Asquith, J. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom); Butterfield, J.S. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom); Ashleigh, R.J. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom)]. E-mail: Ray.Ashleigh@smuht.nhs.uk

    2006-12-15

    Aim: To review our practice of outpatient percutaneous vascular interventions facilitated by an arterial suture device. Materials and methods: A retrospective review of all patients attending this tertiary centre for iliac or femoral intervention was undertaken between February 2001 and December 2004. All patients who underwent angioplasty or stenting had their puncture sites closed using a Perclose suture. Patients were kept flat for 15 min and allowed to fully mobilize at 60 min. Puncture sites were scored for visible bruising, haematoma and pain at discharge and on outpatient follow-up. Patient preference for future outpatient treatment was assessed. Results: Fifty-seven outpatients underwent 81 punctures. Forty-eight (84%) patients underwent iliac angioplasty; of those 42% underwent stent placement. Six patients (10%) required inpatient admission, five secondary to failed suture deployment. One patient had a non-closer-related puncture site intimal flap occlusion successfully repaired at surgery. Fifty-one (90%) patients discharged with a mean time of 157 min (60-280 min). Forty-six (92%) patients had no visible bruising or palpable haematoma on discharge. No patient had a haematoma greater than 2.5 cm. No discharged patient required readmission. Thirty percent reported a moderate to severe groin pain score (2-5/5) at discharge, increasing to 40% at follow-up. Forty-seven (98%) of the 48 patients, who expressed a preference, would be happy to undergo outpatient treatment again. Conclusion: Outpatient treatment is feasible, well tolerated and preferable to patients, but 10% will require inpatient admission. A planned post-procedure analgesia regimen or advice should be considered.

  11. Biomedical engineering in design and application of nitinol stents with shape memory effect

    Science.gov (United States)

    Ryklina, E. P.; Khmelevskaya, I. Y.; Morozova, Tamara V.; Prokoshkin, S. D.

    1996-04-01

    Our studies in the field of endosurgery in collaboration with the physicians of the National Research Center of Surgery of the Academy of Medical Sciences are carried out beginning in 1983. These studies laid the foundation for the new direction of X-ray surgery--X-ray Nitinol stenting of vessels and tubular structures. X-ray nitinol stents are unique self-fixing shells based on the shape memory effect and superelasticity of nickel-titanium alloys self- reconstructed under human body temperature. Applied for stenting of arteries in cases of stenosis etc., bile ducts in cases of benign and malignant stenoses, digestive tract in cases of oesophageal cancer and cervical canal uterus in cases of postsurgical atresiss and strictures of uterine. The purpose of stenting is restoration of the shape of artery or tubular structure by a cylinder frame formation. The especially elaborated original method of stenting allows to avoid the traditional surgical operation, i.e. the stenting is performed without blood, narcosis and surgical knife. The stent to be implanted is transported into the affected zone through the puncture under the X-ray control. Clinical applications of X-ray endovascular stenting has been started in March 1984. During this period nearly 400 operations on stenting have been performed on femoral, iliac, brachio-cephalic, subclavian arteries, bile ducts, tracheas, digestive tract and cervical canal uterus.

  12. A comparison of a 'J' wire and a straight wire in successful antegrade cannulation of the superficial femoral artery

    International Nuclear Information System (INIS)

    Gay, D.A.T.; Edwards, A.J.; Puckett, M.A.; Roobottom, C.A.

    2005-01-01

    AIMS: To evaluate the success of two different types of wire in common use in their ability to successfully cannulate the superficial femoral artery (SFA) using antegrade puncture. METHODS: 50 consecutive patients in whom antegrade infra-inguinal intervention was planned, underwent common femoral arterial puncture and then cannulation with either a standard 3 mm 'J' wire or a floppy tipped straight wire (William Cook--Europe). The frequency with which each type of wire entered the SFA or profunda femoris artery without image guidance was recorded. Further analysis was also made of the success of manipulation of the wire into the SFA following profunda cannulation and the use of alternative guide wires. RESULTS: In 19 out of 25 (76%) patients the 'J' wire correctly entered the SFA without image guidance. Only 5 out of 25 (25%) of straight wires entered the SFA with the initial pass (p<0.0001). Following further manipulation with the same wire all except 1 'J' wire was successfully negotiated into the SFA. The same was true for only 9 of the remaining straight wires with 11 patients requiring an alternative guide wire. CONCLUSIONS: When performing antegrade cannulation of the SFA a 'J' wire is more likely to be successful than a straight guide wire

  13. Does the real-time ultrasound guidance provide safer venipuncture in implantable venous port implantation?

    Science.gov (United States)

    Yıldırım, İlknur; Tütüncü, Ayşe Çiğdem; Bademler, Süleyman; Özgür, İlker; Demiray, Mukaddes; Karanlık, Hasan

    2018-03-01

    To examine whether the real-time ultrasound-guided venipuncture for implantable venous port placement is safer than the traditional venipuncture. The study analyzed the results of 2153 venous ports placed consecutively from January 2009 to January 2016. A total of 922 patients in group 1 and 1231 patients in group 2 were admitted with venous port placed using the traditional landmark subclavian approach and real-time ultrasound-guided axillary approach, respectively. Sociodemographic characteristics of patients, early (pneumothorax, pinch-off syndrome, arterial puncture, hematoma, and malposition arrhythmia) and late (deep vein thrombosis, obstruction, infection, erosion-dehiscence, and rotation of the port chamber) complications and the association of these complications with the implantation method were evaluated. There were no significant differences in the sociodemographic characteristics of the patients between the two groups. The overall and early complications in group 2 were significantly lower than those in group 1. Pinch-off syndrome only developed in group 1. Seven patients and two patients had pneumothorax in groups 1 and 2, respectively. Puncture number was significantly associated with the development of the overall complications. The ultrasound-guided axillary approach may be preferred as a method to reduce the risk of both early and late complications. Large, randomized, controlled prospective trials will be helpful in determining a safer implantable venous port implantation technique.

  14. Tratamento endovascular de lesões arteriais traumáticas Endovascular management of traumatic arterial injuries

    Directory of Open Access Journals (Sweden)

    Ruy Fernandes e Fernandes

    2011-03-01

    . Todos os procedimentos foram realizados com sucesso. Não se verificou mortalidade. No doente com RAS houve necessidade de cirurgia de descorticação pulmonar esquerda, por hematoma organizado, e o doente com FAV foi submetido com sucesso a nova embolização com coils por recorrência precoce de hematúria. Conclusão: O tratamento endovascular é, em casos seleccionados, uma alternativa válida e menos invasiva de lesões traumáticas complexas em regiões anatómicas de difícil acesso e morbi-mortalidade cirúrgica elevada.Introduction: Traumatic vascular injuries are present in less than 10% of patients with multi-organ trauma and, in western countries, the incidence of iatrogenic vascular lesions has been increasing. Conventional surgery in the approach of these lesions usually requires extended surgical exposure, presents increased technical challenges and has high morbidity and mortality. Recently, several authors have described the successful management of traumatic injuries with endovascular techniques with diminished surgical risk. Endovascular surgery has also been increasingly applied in management of chronic traumatic injuries like chronic post-traumatic thoracic aneurysms with significant improved outcomes. The authors present clinical cases with several acute and chronic traumatic vascular injuries treated with endovascular techniques, Clinical reports: Seven patients (21-77 years with traumatic vascular injuries were treated. Four patients presented acute injuries: 1 case of traumatic aortic injury in a patient with multi-organ trauma after automobile crash; 1 case of iatrogenic subclavian artery rupture after inadvertent subclavian artery catheterization during attempted venous central access ; 1 case of iatrogenic renal artery rupture during renal angioplasty and stenting; 1 case of iatrogenic intra-renal arterio-venous fistula (AVF after laparoscopic resection of a renal tumour. Three patients presented with chronic post-traumatic thoracic aneurysms

  15. Development of a new bench for puncturing of irradiated fuel rods in STAR hot laboratory

    Science.gov (United States)

    Petitprez, B.; Silvestre, P.; Valenza, P.; Boulore, A.; David, T.

    2018-01-01

    A new device for puncturing of irradiated fuel rods in commercial power plants has been designed by Fuel Research Department of CEA Cadarache in order to provide experimental data of high precision on fuel pins with various designs. It will replace the current set-up that has been used since 1998 in hot cell 2 of STAR facility with more than 200 rod puncturing experiments. Based on this consistent experimental feedback, the heavy-duty technique of rod perforation by clad punching has been preserved for the new bench. The method of double expansion of rod gases is also retained since it allows upgrading the confidence interval of volumetric results obtained from rod puncturing. Furthermore, many evolutions have been introduced in the new design in order to improve its reliability, to make the maintenance easier by remote handling and to reduce experimental uncertainties. Tightness components have been studied with Sealing Laboratory Maestral at Pierrelatte so as to make them able to work under mixed pressure conditions (from vacuum at 10-5 mbar up to pressure at 50 bars) and to lengthen their lifetime under permanent gamma irradiation in hot cell. Bench ergonomics has been optimized to make its operating by remote handling easier and to secure the critical phases of a puncturing experiment. A high pressure gas line equipped with high precision pressure sensors out of cell can be connected to the bench in cell for calibration purposes. Uncertainty analyses using Monte Carlo calculations have been performed in order to optimize capacity of the different volumes of the apparatus according to volumetric characteristics of the rod to be punctured. At last this device is composed of independent modules which allow puncturing fuel pins out of different geometries (PWR, BWR, VVER). After leak tests of the device and remote handling simulation in a mock-up cell, several punctures of calibrated specimens have been performed in 2016. The bench will be implemented soon in hot

  16. Laparoscopic Removal of a Large Ovarian Mass Utilizing Planned Trocar Puncture

    Science.gov (United States)

    2012-01-01

    Background: Large cystic ovarian masses pose technical challenges to the laparoscopic surgeon. Removing large, potentially malignant specimens must be done with care to avoid the leakage of cyst fluid into the abdominal cavity. Case: We present the case of a large ovarian cystic mass treated laparoscopically with intentional trocar puncture of the mass to drain and remove the mass. Discussion: Large cystic ovarian masses can be removed laparoscopically with intentional trocar puncture of the mass to facilitate removal without leakage of cyst fluid. PMID:22906344

  17. Recent Advances in Thermoplastic Puncture-Healing Polymers

    Science.gov (United States)

    Bogert, Philip B.; Working, Dennis C.; Wise, Kristopher E.; Smith, Janice Y.; Topping, Crystal C.; Britton, Sean M.; Bagby, Paul R.; Siochi, Emilie J.

    2010-01-01

    The motivation for this work is to develop self-healing polymeric materials to enable damage tolerant systems, and to tailor puncture healing for use temperatures and applications. This will be a benefit in environments and conditions where access for manual repair is limited or impossible, or where damage may not be detected.

  18. Decreased bed rest post-percutaneous coronary intervention with a 7-French arterial sheath and its effects on vascular complications.

    Science.gov (United States)

    Wentworth, Laura J; Bechtum, Elizabeth L; Hoffman, Jessica G; Kramer, Robert R; Bartel, David C; Slusser, Joshua P; Tilbury, Ralph Thomas

    2018-01-01

    To compare the incidence of femoral access puncture site complications in the control group, who underwent 6 hr of bed rest, with patients in the case group, who underwent 4 hr of bed rest. The ideal bed rest length after percutaneous coronary intervention with a 7-French arterial sheath has been investigated by nursing practice. However, in this larger-sheath-size group, best practices have not been determined, and bed rest time continues to vary markedly among institutions. Retrospective study. Data were retrieved from the National Cardiovascular Data Registry and electronic health records in this retrospective study. Sample size was 401 patients: 152 case patients with 4-hr bed rest and 249 controls with 6-hr bed rest. Case group data were obtained from 20 May 2013-31 December 2014; and control group data, 15 June 2011-20 May 2013. National Cardiovascular Data Registry event rates were generally low in both groups: Only three patients in each group had a bleeding event within 72 hr (2% vs. 1%) and no patient and only two controls had arteriovenous fistula (0% vs. 1%). Complications documented in the electronic health records with institutional femoral access puncture site complication definitions identified bleeding at the access site in eight case patients (5%) and nine controls (4%). Haematoma at the access site occurred in 21 case patients (14%) and 25 controls (10%). The practice change of decreasing bed rest from 6-4 hr for patients with 7-French arterial sheaths post-percutaneous coronary intervention was associated with no significant change in femoral access puncture site complications in either National Cardiovascular Data Registry data or institutional electronic health records data. This introduces expanded evidence of safety in decreasing bed rest length in larger (7-French) arterial sheaths post-percutaneous coronary intervention. © 2017 John Wiley & Sons Ltd.

  19. Safety and effectiveness of a circumferential clip-based vascular closure device for hemostasis in off-label applications: Comparison with standard applications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Chan; Kim, Chang Won [Dept. of Radiology, Pusan National University School of Medicine, Pusan National University Hospital, Busan (Korea, Republic of); Jeon, Ung Bae [Dept. of Radiology, Pusan National University School of Medicine, Yangsan Pusan National University Hospital, Yangsan (Korea, Republic of)

    2016-09-15

    We investigated the efficacy and safety of a circumferential nitinol clip based arterial closure device following arteriotomy, especially in off-label applications. Consecutive patients who underwent the procedure with arteriotomy from January 2011 to February 2014 were included in this study. We defined standard use as the use of StarClose for retrograde puncture of the common femoral artery (CFA) and off-label use as the use of StarClose for retrograde puncture of the superficial femoral artery (SFA), antegrade puncture of the CFA or SFA, puncture of the brachial artery or puncture of the vascular graft. The procedures performed included percutaneous transluminal angioplasty and thrombolysis. Technical success was defined as complete hemostasis achieved within 3 minute after the closure. Complications, and laboratory findings associated with coagulation function, were also investigated. There were 146 cases of standard applications and 111 cases of off-label applications. Technical success was achieved in all cases. The off-label group comprised the use of StarClose for retrograde puncture of the SFA (n = 19), antegrade puncture of the CFA or SFA (n = 74), brachial artery puncture (n = 5), larger sheath than 6 Fr (n = 7) and vascular graft puncture (n = 6). Minor complications were noted in both groups (standard group: 7.5%, off-label group: 2.7%). Off-label use of StarClose is safe and feasible.

  20. Safety and effectiveness of a circumferential clip-based vascular closure device for hemostasis in off-label applications: Comparison with standard applications

    International Nuclear Information System (INIS)

    Lee, Seung Chan; Kim, Chang Won; Jeon, Ung Bae

    2016-01-01

    We investigated the efficacy and safety of a circumferential nitinol clip based arterial closure device following arteriotomy, especially in off-label applications. Consecutive patients who underwent the procedure with arteriotomy from January 2011 to February 2014 were included in this study. We defined standard use as the use of StarClose for retrograde puncture of the common femoral artery (CFA) and off-label use as the use of StarClose for retrograde puncture of the superficial femoral artery (SFA), antegrade puncture of the CFA or SFA, puncture of the brachial artery or puncture of the vascular graft. The procedures performed included percutaneous transluminal angioplasty and thrombolysis. Technical success was defined as complete hemostasis achieved within 3 minute after the closure. Complications, and laboratory findings associated with coagulation function, were also investigated. There were 146 cases of standard applications and 111 cases of off-label applications. Technical success was achieved in all cases. The off-label group comprised the use of StarClose for retrograde puncture of the SFA (n = 19), antegrade puncture of the CFA or SFA (n = 74), brachial artery puncture (n = 5), larger sheath than 6 Fr (n = 7) and vascular graft puncture (n = 6). Minor complications were noted in both groups (standard group: 7.5%, off-label group: 2.7%). Off-label use of StarClose is safe and feasible

  1. Conformal blocks on a 2-sphere with indistinguishable punctures and implications on black hole entropy

    Directory of Open Access Journals (Sweden)

    Abhishek Majhi

    2016-11-01

    Full Text Available The dimensionality of the Hilbert space of a Chern–Simons theory on a 3-fold, in the presence of Wilson lines carrying spin representations, had been counted by using its link with the Wess–Zumino theory, with level k, on the 2-sphere with points (to be called punctures marked by the piercing of the corresponding Wilson lines and carrying the respective spin representations. It is shown, in the weak coupling (large k limit, the formula decouples into two characteristically distinct parts; one mimics the dimensionality of the Hilbert space of a collection of non-interacting spin systems and the other is an effective overall correction contributed by all the punctures. The exact formula yield from this counting has been shown earlier to have resulted from the consideration of the punctures to be distinguishable. We investigate the same counting problem by considering the punctures to be indistinguishable. Although the full formula remains undiscovered, nonetheless, we are able to impose the relevant statistics for indistinguishable punctures in the approximate formula resulting from the weak coupling limit. As an implication of this counting, in the context of its relation to that of black hole entropy calculation in quantum geometric approach, we are able to show that the logarithmic area correction, with a coefficient of −3/2, that results in this method of entropy calculation, in independent of whether the punctures are distinguishable or not.

  2. CT guided percutaneous renal cysts puncture with ethanol therapy

    International Nuclear Information System (INIS)

    Zhang Xuezhe; Lu Yan; Wang Wu; Huang Zhengguo; Ren An

    2002-01-01

    Objective: To analyse our clinical experience with CT guided percutaneous renal cysts puncture and ethanol therapy. Methods: Five hundred and ten renal cysts in 445 patients were undergone CT guided percutaneous renal cysts puncture and ethanol therapy. Among the 445 cases, 385 cases had solitary renal cyst, 53 multiple renal cysts, and 7 polycystic kidneys. The renal cysts varied in size from 1.9 to 13.5 cm in diameter. The amount of aspirated fluid varied from 3 to 780 ml. A 18-21 gauge aspiration needles were used for all patients. A 25.0% cyst volume replacement with 99.7% ethanol was approved to be appropriate. Results: 427 renal cysts in 396 patients were followed up by computed tomographic (CT) or ultrasound for less than 3 months to more than one year duration. The curative effective rate and disappearance rate of the renal cystic cavity in solitary renal cysts were 97% and 82%, respectively. In multiple renal cysts, the corresponding values were 95% and 79%. In polycystic kidneys, the curative rate was 67%. The complications such as local abdominal pain (28 cases) and hematuria (four cases) were observed in this series. There were no fatal complications. Conclusions: CT guided percutaneous renal cyst puncture and ethanol therapy is an useful procedure for the treatment of solitary renal cysts and multiple renal cysts

  3. Design of Rate-Compatible Parallel Concatenated Punctured Polar Codes for IR-HARQ Transmission Schemes

    Directory of Open Access Journals (Sweden)

    Jian Jiao

    2017-11-01

    Full Text Available In this paper, we propose a rate-compatible (RC parallel concatenated punctured polar (PCPP codes for incremental redundancy hybrid automatic repeat request (IR-HARQ transmission schemes, which can transmit multiple data blocks over a time-varying channel. The PCPP coding scheme can provide RC polar coding blocks in order to adapt to channel variations. First, we investigate an improved random puncturing (IRP pattern for the PCPP coding scheme due to the code-rate and block length limitations of conventional polar codes. The proposed IRP algorithm only select puncturing bits from the frozen bits set and keep the information bits unchanged during puncturing, which can improve 0.2–1 dB decoding performance more than the existing random puncturing (RP algorithm. Then, we develop a RC IR-HARQ transmission scheme based on PCPP codes. By analyzing the overhead of the previous successful decoded PCPP coding block in our IR-HARQ scheme, the optimal initial code-rate can be determined for each new PCPP coding block over time-varying channels. Simulation results show that the average number of transmissions is about 1.8 times for each PCPP coding block in our RC IR-HARQ scheme with a 2-level PCPP encoding construction, which can reduce half of the average number of transmissions than the existing RC polar coding schemes.

  4. The blind pushing technique for peripherally inserted central catheter placement through brachial vein puncture.

    Science.gov (United States)

    Lee, Jae Myeong; Cho, Young Kwon; Kim, Han Myun; Song, Myung Gyu; Song, Soon-Young; Yeon, Jae Woo; Yoon, Dae Young; Lee, Sam Yeol

    2018-03-01

    The objective of this study was to conduct a prospective clinical trial evaluating the technical feasibility and short-term clinical outcome of the blind pushing technique for placement of pretrimmed peripherally inserted central catheters (PICCs) through brachial vein access. Patients requiring PICC placement at any of the three participating institutions were prospectively enrolled between January and December 2016. The review boards of all participating institutions approved this study, and informed consent was obtained from all patients. PICC placement was performed using the blind pushing technique and primary brachial vein access. The following data were collected from unified case report forms: access vein, obstacles during PICC advancement, procedure time, and postprocedural complications. During the 12-month study period, 1380 PICCs were placed in 1043 patients. Of these, 1092 PICCs placed in 837 patients were enrolled, with 834 PICCs (76%) and 258 PICCs (34%) placed through brachial vein and nonbrachial vein access, respectively. In both arms, obstacles were most commonly noted in the subclavian veins (n = 220) and axillary veins (n = 94). Successful puncture of the access vein was achieved at first try in 1028 PICCs (94%). The technical success rate was 99%, with 1055 PICCs (97%) placed within 120 seconds of procedure time and 1088 PICCs (99%) having the tip located at the ideal position. Follow-up Doppler ultrasound detected catheter-associated upper extremity deep venous thrombosis (UEDVT) for 18 PICCs in 16 patients and late symptomatic UEDVT for 16 PICCs in 16 patients (3.1%). Catheter-associated UEDVT was noted for 28 PICCs (82%) and 6 PICCs (18%) placed through brachial vein and nonbrachial vein access, respectively. The incidence of obstacles and the procedure time (pushing technique and primary brachial vein access is technically feasible and may represent an alternative to the conventional PICC placement technique, having low incidences of

  5. Gadolinium-enhanced MR angiography of arterial occlusive disease in lower extremity : comparison with conventional digital subtraction angiography

    International Nuclear Information System (INIS)

    Shin, Sang June; Koh, Young Hwan; Cha, Joo Hee; Kim, Hyu Beom; Chung, Jin Wook; Park, Jae Hyung

    2000-01-01

    To compare the diagnostic value of gadolinium-enhanced MR angiography with that of conventional digital subtraction angiography for the evaluation of lower extremity arterial occlusive diseases. In 26 patients with symptomatic lower extremity arterial occlusive disease, both conventional digital subtraction angiography (DSA) and gadolinium-enhanced MR angiography (CE-MRA) were performed during the same week. MR angiography was performed using three-dimensional gradient-echo acquisition before, and two sequential acquisitions after, the administration of gadolinium (0.2 mmol/kg). In 23 patients, two separate, contiguous areas were scanned using additional doses. In three patients, only one field with a suspicious lesion was scanned. Three radiologists independently analyzed the CE-MRA and DSA findings of each vascular segment (20 segments per arterial tree) for the presence of obstructive lesions; the grade assigned was either mild or none (less than 50%), stenotic (50%-99%), or occlusion (100%). From among a total of 462 segments, DSA detected 99 which were significantly narrowed (stenosis, 33; occlusion, 66). Using MR angiography, 102 segments (stenosis 39; occlusion, 63) were identified, and 94 lesions (stenosis, 32; occlusion, 62) were graded correctly. Seven lesions were overestimated and four were underestimated. For the detection of hemodynamically significant stenosis or occlusions using MR angiography, sensitivity, specificity, and diagnostic accuracy were 95%, 98%, and 98% (G=3D0.995, P less than 0.001), respectively. To prove the absence of lesions, we repeated DSA in two patients with arterial spasm due to puncture. Three occluded segments seen on DSA, which revealed intact segments on MR angiography, suggested slow distal flow after reconstitution. For the evaluation of lower extremity arterial occlusive disease, the diagnostic value of gadolinium-enhanced MR angiography is comparable with that of digital subtraction angiography. The advantages of the

  6. Angiographic findings of collateral vessels in cervicofacial vascular lesions with previously ligated carotid artery

    International Nuclear Information System (INIS)

    Na, Dong Gyu; Han, Moon Hee; Chang, Kee Hyun; Han, Gi Seok; Yeon, Kung Mo

    1995-01-01

    The purpose of this study is to describe the angiographic findings of collateral vessels in cervicofacial vascular lesions with previously ligated carotid arteries and to evaluate the extent of angiographic assessment needed before embolization. We retrospectively reviewed 10 cervicofacial vascular lesions with previously ligated carotid artery, which were 6 cases of arteriovenous malformation, 2 cases of carotid cavernous fistula, 1 case of hemangioma and 1 case of arteriovenous malformation with carotid cavernous fistula. The previously ligated arteries are proximal external carotid artery (n = 5), branches of external carotid artery (n = 2) and common carotid artery (n = 3). Common carotid artery or internal carotid artery (n = 9), vertebral artery (n = 5), ipsilateral external carotid artery (n = 4), contralateral external carotid artery (n = 5), costocervical trunk (n = 2), thyrocervical trunk (n = 2) were assessed by conventional angiography. Angiography of both carotid and vertebral arteries was performed in 5 cases. The collateral vascular channels were inferolateral trunk of internal carotid artery (n = 8), vertebral artery (n = 5), contralateral external carotid artery (n = 5), ipsilateral external carotid artery (n = 4), deep cervical artery (n = 2) and ascending cervical artery (n = 1). Embolization were performed in 9 cases with operative cannulation (n = 4), embolization via collateral branches of ipsilateral external carotid artery (n = 1), embolization via collateral branches of contralateral external carotid artery (n = 3) and balloon occlusion via direct puncture (n = 1). The collateral channels in cervicofacial vascular lesions with previously ligated carotid artery were inferolateral trunk of internal carotid artery, contralateral or ipsilateral external carotid artery, vertebral artery, deep cervical artery and ascending cervical artery on angiography. Complete angiographic assessment of possible collateral channels is mandatory for the

  7. Feasibility study on retinal vascular bypass surgery in isolated arterially perfused caprine eye model

    Science.gov (United States)

    Chen, Y; Wu, W; Zhang, X; Fan, W; Shen, L

    2011-01-01

    Purpose To investigate the feasibility of bypassing occluded segments of retinal venous main vessels in isolated, arterially perfused caprine eyes via the closed-sky vitrectomy approach using keratoprosthesis. Methods Isolated caprine eyes were used in this study. For each eye, the retinal vessel was perfused by Krebs solution via ophthalmic artery, and pars plana vitrectomy was performed using temporary keratoprosthesis. All retinal micro-vascular maneuvers were performed in a closed-sky eyeball. The main retinal vein was blocked by endodiathermy at the site of the vessel's first branching. Two openings, several millimeters apart, were created by vascular punctures in both the main vein and its branch vein wall straddling the induced occluded segment. Catheterization was achieved using a flexible polyimide tube, with each end inserted into the vessel wall opening. A sealed connection between the vessel and the tube was obtained by endodiathermy. Bypass of the occluded retinal vein segment was thus achieved, and the patency of this vascular bypass was confirmed by intravascular staining. Results Puncturing, catheterization, and endodiathermy were viable by closed-sky approach using keratoprosthesis. Bypassing of the occluded retinal main vein segment was accomplished with the combination of these maneuvers. Good results were obtained in 23 of 38 (60%) caprine eyes. Conclusions This study demonstrated that bypassing the occluded segment of retinal main vein can be successfully performed in a closed-sky eyeball model of isolated, arterially perfused caprine eye. This early work indicated that the more advanced retinal vascular bypass surgery in in vivo eye may be feasible in the future. PMID:21921946

  8. Combined use of intraarterial digital subtraction angiography with conventional retrograde brachial vertebral angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tatsuo; Ogawa, Toshihide; Inugami, Atsushi; Kawata, Yasushi; Shishido, Fumio; Uemura, Kazuo

    1985-01-01

    For 102 patients who had the examination of conventional bilaterally retrograde brachial vertebral angiography (retrograde VAG), intraarterial digital subtraction angiography (DSA) was successively performed to investigate steno-occlusive lesions of proximal vertebral and subclavian arteries. All the patients had no complication due to the DSA procedure. In 50% of 72 ischemic stroke cases, positive findings were found either in the origin of the vertebral artery or in the subclavian artery. Stenosis of more than 50% of the lumen of the vertebral artery were found in 14% of the cases at the origin of the right one and also in 14% in the left one. Occlusion of the vertebral artery was found in 4% in the left side only. In 30 cases with non-ischemic brain diseases, positive findings were noted in 10%. Intraarterial DSA combined with retrograde VAG was thought to be useful, especially in the examination for ischemic stroke. (author)

  9. Heme oxygenase-1 modulates degeneration of the intervertebral disc after puncture in Bach 1 deficient mice.

    Science.gov (United States)

    Ohta, Ryo; Tanaka, Nobuhiro; Nakanishi, Kazuyoshi; Kamei, Naosuke; Nakamae, Toshio; Izumi, Bunichiro; Fujioka, Yuki; Ochi, Mitsuo

    2012-09-01

    Intervertebral disc degeneration is considered to be a major feature of low back pain. Furthermore, oxidative stress has been shown to be an important factor in degenerative diseases such as osteoarthritis and is considered a cause of intervertebral disc degeneration. The purpose of this study was to clarify the correlation between oxidative stress and intervertebral disc degeneration using Broad complex-Tramtrack-Bric-a-brac and cap'n'collar homology 1 deficient (Bach 1-/-) mice which highly express heme oxygenase-1 (HO-1). HO-1 protects cells from oxidative stress. Caudal discs of 12-week-old and 1-year-old mice were evaluated as age-related models. Each group and period, 5 mice (a total of 20 mice, a total of 20 discs) were evaluated as age-related model. C9-C10 caudal discs in 12-week-old Bach 1-/- and wild-type mice were punctured using a 29-gauge needle as annulus puncture model. Each group and period, 5 mice (a total of 60 mice, a total of 60 discs) were evaluated. The progress of disc degeneration was evaluated at pre-puncture, 1, 2, 4, 8 and 12 weeks post-puncture. Radiographic, histologic and immunohistologic analysis were performed to compare between Bach 1-/- and wild-type mice. In the age-related model, there were no significant differences between Bach 1-/- and wild-type mice radiologically and histologically. However, in the annulus puncture model, histological scoring revealed significant difference at 8 and 12 weeks post-puncture. The number of HO-1 positive cells was significantly greater in Bach 1-/- mice at every period. The apoptosis rate was significantly lower at 1 and 2 weeks post-puncture in Bach 1-/- mice. Oxidative stress prevention may avoid the degenerative process of the intervertebral disc after puncture, reducing the number of apoptosis cells. High HO-1 expression may also inhibit oxidative stress and delay the process of intervertebral disc degeneration.

  10. Thoracic outlet syndrome: Case report

    International Nuclear Information System (INIS)

    Marquez, Juan Camilo; Acosta, Mauricio Fernando; Uribe Jorge Ricardo

    2009-01-01

    We report a case of vascular thoracic outlet syndrome in a young man, diagnosed with upper limb arteriography, leading to repeated arterio-arterial emboli originating from a post-stenotic subclavian artery aneurysm. It is of our interest due to its low incidence and the small number of cases reported that have been diagnosed by arteriography. The thoracic outlet is the path through which vascular and neural structures goes from the neck to the axilla, and it has three anatomical strictures, that when pronounced, can compress the brachial plexus or subclavian vessels, leading to different symptoms and signs.

  11. The establishment of implanted VX2 liver tumor model in rabbits and discussion on superselective left hepatic arterial catheterization with micro-catheter technique via femoral artery

    International Nuclear Information System (INIS)

    Jiang Xiongying; Luo Rongguang; Huang Jinhua; Miao Bijian; Wang Yan

    2011-01-01

    Objective: To establish the implanted VX2 liver tumor model in rabbits and to discuss the feasibility and technical features of superselective left hepatic arterial catheterization by using micro-catheter through the femoral artery catheter sheath. Methods: Forty New Zealand white rabbits were inoculated with fragments of VX2 tumor into the medial left lobe of liver by using a 16G lumbar puncture needle through laparotomy route. Two weeks later, all the rabbits were proved to be successfully inoculated with liver neoplasm on CT scanning. Then, the catheter sheath was inserted into one of the femoral arteries, which was followed by celiac artery angiography and left hepatic artery catheterization with a micro-catheter under DSA guidance in order to evaluate the main branches of celiac artery and the imaging manifestations of VX2 liver tumor. After that, some scheduled interventional experiments were carried out. Results: Imaging examination and histopathologic study showed that the successful rate of implanted rabbit VX2 liver tumor was 100% (40/40). And the successful rate of the catheter sheath inserted to femoral artery was 97.5% (39/40). The successful rate of celiac artery, gastro-hepatic artery, common hepatic artery, proper hepatic artery and left hepatic artery catheterizations was 100% (39/39), 100% (39/39), 100% (39/39), 94.9% (37/39) and 71.2% (28/39) respectively. Conclusion: To implant tumor tissue mass through laparotomy is a stable and reliable method to establish rabbit VX2 liver tumor model. The insertion of micro-catheter through rabbit femoral catheter sheath approach is a convenient and simple technique to be carried out for the left hepatic artery catheterization and it can efficiently solve the technical difficulties when performing the interventional treatment of the rabbit VX2 hepatic tumor via left hepatic artery approach. (authors)

  12. Pleural puncture with thoracic epidural: A rare complication?

    Directory of Open Access Journals (Sweden)

    Rachna Wadhwa

    2011-01-01

    Full Text Available Freedom from pain has almost developed to be a fundamental human right. Providing pain relief via epidural catheters in thoracic and upper abdominal surgeries is widely accepted. Pain relief through this technique not only provides continuous analgesia but also reduces post-operative pulmonary complications and also hastens recovery. But being a blind procedure it is accompanied by certain complications. Hypotension, dura puncture, high epidural, total spinal, epidural haematoma, spinal cord injury and infection are some of the documented side effects of epidural block. There are case reports eliciting neurological complications, catheter site infections, paresthesias, radicular symptoms and worsening of previous neurological conditions. Few technical problems related to breakage of epidural catheter are also mentioned in the literature. The patient had no sequelae on long term follow up even when a portion of catheter was retained. We present a case report where epidural catheter punctured pleura in a patient undergoing thoracotomy for carcinoma oesophagus.

  13. Ultrasound-Guided Cannulation: Time to Bring Subclavian Central Lines Back

    Directory of Open Access Journals (Sweden)

    Talayeh Rezayat, DO, MPH

    2016-03-01

    Full Text Available Despite multiple advantages, subclavian vein (SCV cannulation via the traditional landmark approach has become less used in comparison to ultrasound (US guided internal jugular catheterization due to a higher rate of mechanical complications. A growing body of evidence indicates that SCV catheterization with real-time US guidance can be accomplished safely and efficiently. While several cannulation approaches with real-time US guidance have been described, available literature suggests that the infraclavicular, longitudinal “in-plane” technique may be preferred. This approach allows for direct visualization of needle advancement, which reduces risk of complications and improves successful placement. Infraclavicular SCV cannulation requires simultaneous use of US during needle advancement, but for an inexperienced operator, it is more easily learned compared to the traditional landmark approach. In this article, we review the evidence supporting the use of US guidance for SCV catheterization and discuss technical aspects of the procedure itself.

  14. Subcutaneous Emphysema Induced by Cryotherapy: A Complication due to Previous Punctures

    Directory of Open Access Journals (Sweden)

    Jared Martínez-Coronado

    2015-01-01

    Full Text Available Cryosurgery is a common therapeutic modality used in dermatology; therefore we must be aware of its possible adverse effects. We report a case of a patient with subcutaneous emphysema which occurred following the application of cryotherapy after multiple punctures of local anesthetic and intralesional steroids in a chest keloid scar. Despite the fact that this condition was gradually resolved after expectant observation, we warn about this complication when sprayed cryotherapy is preceded by multiple punctures on cutaneous lesions above bony surfaces. In similar settings, cryotherapy must be first administered or a cotton-tip applicator should be used.

  15. Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography

    International Nuclear Information System (INIS)

    Yoon, Seok Hwan; Lee, Won Hong; Lee, Dae Hyung

    2009-01-01

    Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of

  16. Implantation port-catheter permanent indwelling of pulmonary artery in treating lung metastasis from HCC

    International Nuclear Information System (INIS)

    Cheng Jiemin; Wang Jianhua; Yan Zhiping; Wang Xiaolin; Gong Gaoquan; Liu Qingxin

    2000-01-01

    Objective: To observe the efficacy of a percutaneous implantation port-catheter permanent indwelling pulmonary artery for regional chemotherapy of the metastatic lung cancer from HCC. Methods: Between 1995 and 1999, 62 patients (42 males, 20 females; mean age 46 years) suffering from the metastatic lung cancer from HCC underwent percutaneous implantation of port-catheter permanent indwelling pulmonary artery using the right subclavian vein. In 19 patients with metastatic tumor located on one side of the lung, an indwelling catheter was placed into the ipsilateral side pulmonary artery. With metastasis of both sides, the catheter was inserted into the main trunk of pulmonary artery. The regimens of the chemotherapy were 5-FU + CDDP + MMC(FDM) or 5-FU + CDDP + MMC(FDA). Results: The interventional procedure was successfully completed in all 62 cases (100%). The complications occurred in 8% cases, including infections (3.2%), unhealed wound (1.6%) and pneumothorax (3.2%). The treatment effects of 3-months after the procedure were as follows: the obvious decrease of lung tumor size was 35.5%; stable disease (SD) 32.3% and progressive disease (PD) 32.3%. 6 months follow-up: 12 patients were dead (12/62) and the others are still doing well. The response rates were 22.6%, partial response (PR) 32.3%; stable disease (SD) 25.8% and progressive disease (PD) 32.3%. Conclusions: The percutaneous implantation techniques of pulmonary arterial port-catheter could be a good method in the treatment of metastatic lung cancer from HCC because of it is simple, with few complications and positive effect

  17. The influence of punctural millimeter wave therapy on clinical presentation of patients with essential hypertention

    Directory of Open Access Journals (Sweden)

    Kotenko К.V.

    2013-12-01

    Full Text Available Aim: to estimate the influence of punctural millimeter wave therapy on clinical presentation. Material and methods. This study includes 102 patients with essential hypertension the I and II stage. Patients were divided into three equal groups depending on the method of treatment: some of them received procedures of punctural millimeter wave therapy, some of them received these procedures as the "placebo" and those who had not received specified procedures. Dynamics of clinical symptomatology and condition of eye bottom vessels was estimated. It was shown that addition of punctural millimeter wave therapy in complex therapy of patients with essential hypertension promotes the expressed regress of clinical symptomatology and state normalization the retinal vessels at these patients. Results. Addition of punctural millimeter wave therapy into the complex therapy was shown to lead to pronounced regress of clinical symptoms. Conclusion. The received results allow to recommend this method to be used in clinical practice for treating patients with essential hypertension.

  18. Routine Cranial Computed Tomography before Lumbar Puncture in ...

    African Journals Online (AJOL)

    Background: Current international guidelines recommend that a cranial computed tomography (CT) be performed on all HIV-positive patients presenting with new onset seizures, before a lumbar puncture (LP) is performed. In the South African setting, however this delay could be life threatening. The present study sought to ...

  19. The effects of needle deformation during lumbar puncture

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2015-01-01

    Full Text Available Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP. Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1% of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3% of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%. Forty-seven (41.5% patients experienced post lumbar puncture headache (PLPH and 13 (11.5% patients experienced intracranial hypotension (IH. No statistically significant correlation between the degree of deflection and headache was found (P > 0.05. Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  20. The effects of needle deformation during lumbar puncture

    Science.gov (United States)

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  1. Percutaneous implantation of intra-arterial port system for regional drug infusion: results and complications in 110 cases

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Hyuk; Ko, Kyung Hee; Won, Jong Yoon; Park, Sung Il; Lee, Do Yun; Kang, Byung Chul

    2000-01-01

    To investigate the feasibility and complications of a percutaneously implantable port system for regional drug infusion. For intra-arterial drug infusion, a 5.8 or 5-F pediatric venous port system was implanted in 110 patients with hepatocellular carcinoma (n=79), liver metastasis (n=16), gallbladder cancer (n=4), stomach cancer (n=3), pancreatic cancer (n=3), Burger's diseases mellitus (n=2), or lymphoma (n=1). All intra-arterial port implantations were performed percutaneously in an angiographic ward through the common femoral artery (n=98), left subclavian artery (n=10), or left superficial femoral artery (n=2). Complications were evaluated during the follow-up period, which ranged from 21 to 530 (mean, 163) days. The technical success rate for percutaneous implantation of the system was 97.3% (107 of 110 patients). The tips of the port catheter were located in the common hepatic artery (n=34), proper hepatic artery (n=49), right hepatic artery quick resulthepatic artery (n=1), descending aorta at T9 level (n=10), left popliteal artery (n=2), right external iliac artery (n=1), left external iliac artery (n=1), or left deep femoral artery (n=1). Complications were encountered in 24 patients (22.4%), namely chamber site infection (n=7), catheter dislodgement (n=7), catheter occlusion (n=3), migration of coil (n=2), disconnection between chamber and catheter (n=1), kinking of catheter (n=1), arterial occlusion (n=1), necrosis of overlying skin (n=1), and leakage around port chamber (n=1). Outcomes of complications included removal of port systems or cessation of therapy in 12 cases (11.2%), correction of catheter location using a guide wire in five (4.7%), thrombolysis with urokinase in three (2.8%), and straightening using a snare in one (0.9%). In three patients, the port system was used without reintervention. Percutaneous implantation of an intra-arterial port system showed a high technical success rate and a low rate of serious complications. The method may be

  2. Quasiequilibrium states of black hole-neutron star binaries in the moving-puncture framework

    International Nuclear Information System (INIS)

    Kyutoku, Koutarou; Shibata, Masaru; Taniguchi, Keisuke

    2009-01-01

    General relativistic quasiequilibrium states of black hole-neutron star binaries are computed in the moving-puncture framework. We propose three conditions for determining the quasiequilibrium states and compare the numerical results with those obtained in the excision framework. We find that the results obtained in the moving-puncture framework agree with those in the excision framework and with those in the third post-Newtonian approximation for the cases that (i) the mass ratio of the binary is close to unity irrespective of the orbital separation, and (ii) the orbital separation is large enough (m 0 Ω 0 and Ω are the total mass and the orbital angular velocity, respectively) irrespective of the mass ratio. For m 0 Ω > or approx. 0.03, both of the results in the moving-puncture and excision frameworks deviate, more or less, from those in the third post-Newtonian approximation. Thus the numerical results do not provide a quasicircular state, rather they seem to have a non-negligible eccentricity of order 0.01-0.1. We show by numerical simulation that a method in the moving-puncture framework can provide approximately quasicircular states in which the eccentricity is by a factor of ∼2 smaller than those in quasiequilibrium given by other approaches.

  3. Gelatin model for training ultrasound-guided puncture

    Directory of Open Access Journals (Sweden)

    Alexandre Campos Moraes Amato

    2015-09-01

    Full Text Available BACKGROUND: It is indispensable that members of the medical profession receive the technical training needed to enable them to rapidly obtain effective vascular access. Training procedures should be used judiciously to familiarize students with the technique. However, existing models are expensive or ineffective, and models need to be developed that are similar to what will be encountered in real patients.OBJECTIVES: To demonstrate creation and application of a gelatin model for training ultrasound-guided puncture.METHOS: The model was made using a mixture of colorless gelatin and water in a transparent plastic receptacle with two pairs of orifices of different diameters, through which two plastic tubes were inserted, to simulate blood vessels.RESULTS: The model was a close approximation to the real medical procedure in several aspects, since gelatin has a similar consistency to human tissues, providing a more faithful reproduction of the tactile sensation at the moment when the needle reaches the interior of a vessel and its contents are aspirated.CONCLUSIONS: The method proposed here can be used to easily construct a low-cost model using everyday materials that is suitable for large-scale training of ultrasound-guided puncture.

  4. Ectopic origin of bronchial arteries: assessment with multidetector helical CT angiography

    International Nuclear Information System (INIS)

    Hartmann, Ieneke J.C.; Remy-Jardin, Martine; Menchini, Laura; Teisseire, Antoine; Khalil, Chadi; Remy, Jacques

    2007-01-01

    The purpose of this study was to determine non-invasively the frequency of ectopic bronchial arteries (BA) (i.e., bronchial arteries originating at a level of the descending aorta other than T5-T6 or from any aortic collateral vessel) on multidetector-row CT angiograms (CTA) obtained in patients with hemoptysis. Over a 5-year period (2000-2005), 251 consecutive patients with hemoptysis underwent multidetector-row CT angiography of the thorax. From this population, 37 patients were excluded because of a suboptimal CTA examination (n = 19), the presence of extensive mediastinal disease (n = 15) or severe chest deformation (n = 3) precluding any precise analysis of the bronchial arteries at CTA. Our final study group included 214 patients who underwent a thin-collimated CT angiogram (contrast agent: 300 to 350 mg/ml) on a 4- (n = 56), 16- (n = 119) and 64- (n = 39) detector-row scanner. The site of origin and distribution of bronchial arteries were analyzed on transverse CT scans, maximum intensity projections and volume-rendered images. The site of the ostium of a bronchial artery was coded as orthotopic when the artery originated from the descending aorta between the levels of the fifth and sixth thoracic vertebrae; all other bronchial arteries were considered ectopic. From the studied population, 137 (64%) patients had only orthotopic bronchial arteries, whereas 77 patients (36%) had at least one bronchial artery of ectopic origin. A total of 147 ectopic arteries were depicted, originating as common bronchial trunks (n = 23; 19%) or isolated right or left bronchial arteries (n = 101; 81%). The most frequent sites of origin of the 124 ostiums were the concavity of the aortic arch (92/124; 74%), the subclavian artery (13/124; 10.5%) and the descending aorta (10/124; 8.5%). The isolated ectopic bronchial arteries supplied the ipsilateral lung in all but three cases. Bronchial artery embolization was indicated in 26 patients. On the basis of CTA information, (1

  5. Correlation of Descriptive Analysis and Instrumental Puncture Testing of Watermelon Cultivars.

    Science.gov (United States)

    Shiu, J W; Slaughter, D C; Boyden, L E; Barrett, D M

    2016-06-01

    The textural properties of 5 seedless watermelon cultivars were assessed by descriptive analysis and the standard puncture test using a hollow probe with increased shearing properties. The use of descriptive analysis methodology was an effective means of quantifying watermelon sensory texture profiles for characterizing specific cultivars' characteristics. Of the 10 cultivars screened, 71% of the variation in the sensory attributes was measured using the 1st 2 principal components. Pairwise correlation of the hollow puncture probe and sensory parameters determined that initial slope, maximum force, and work after maximum force measurements all correlated well to the sensory attributes crisp and firm. These findings confirm that maximum force correlates well with not only firmness in watermelon, but crispness as well. The initial slope parameter also captures the sensory crispness of watermelon, but is not as practical to measure in the field as maximum force. The work after maximum force parameter is thought to reflect cellular arrangement and membrane integrity that in turn impact sensory firmness and crispness. Watermelon cultivar types were correctly predicted by puncture test measurements in heart tissue 87% of the time, although descriptive analysis was correct 54% of the time. © 2016 Institute of Food Technologists®

  6. Intra-arterial Ultra-low-Dose CT Angiography of Lower Extremity in Diabetic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Özgen, Ali, E-mail: draliozgen@hotmail.com [Yeditepe University Hospital, Department of Radiology (Turkey); Sanioğlu, Soner [Yeditepe University Hospital, Department of Cardiovascular Surgery (Turkey); Bingöl, Uğur Anıl [Yeditepe University Hospital, Department of Plastic Surgery (Turkey)

    2016-08-15

    PurposeTo image lower extremity arteries by CT angiography using a very low-dose intra-arterial contrast medium in patients with high risk of developing contrast-induced nephropathy (CIN).Materials and MethodsThree cases with long-standing diabetes mellitus and signs of lower extremity atherosclerotic disease were evaluated by CT angiography using 0.1 ml/kg of the body weight of contrast medium given via 10-cm-long 4F introducer by puncturing the CFA. Images were evaluated by an interventional radiologist and a cardiovascular surgeon. Density values of the lower extremity arteries were also calculated. Findings in two cases were compared with digital subtraction angiography images performed for percutaneous revascularization. Blood creatinine levels were followed for possible CIN.ResultsIntra-arterial CT angiography images were considered diagnostic in all patients and optimal in one patient. No patient developed CIN after intra-arterial CT angiography, while one patient developed CIN after percutaneous intervention.ConclusionIntra-arterial CT angiography of lower extremity might be performed in selected patients with high risk of developing CIN. Our limited experience suggests that as low as of 0.1 ml/kg of the body weight of contrast medium may result in adequate diagnostic imaging.

  7. [The relationship between angle of puncture and distribution of bone cement of unilateral percutaneous kyphoplasty for the treatment of thoracolumbar compression fractures].

    Science.gov (United States)

    Wang, Xiang-fu; Fan, You-fu; Shi, Rui-fang; Deng, Qiang; Li, Zhong-feng

    2015-08-01

    To explore the relationship of bone cement distribution and the puncture angle in the treatment of thoracolumbar compression fractures with unilateral percutaneous kyphoplasty (PKP). The clinical data of 37 patients with thoracolumbar osteoporotic compression fractures underwent PKP between January 2013 to March 2014 were retrospectively analyzed, all punctures were performed unilaterally. There were 6 males, aged from 65 to 78 years old with an average of (71.83 ± 6.15) years; and 31 females, aged from 57 to 89 years old with an average of (71.06 ± 7.89) years. Imaging data were analyzed and puncture angle and puncture point were measured before operation. According to the measured data, the puncture were performeds during the operation. Distribution area of bone cement were calculated by X-rays data after operation. The effect of bone cement distribution on suitable puncture angle was analyzed; VAS score was used to evaluate the clinical effects. The puncture angle of thoracic vertebrae in T8-T12 was from 28° to 33° with an average 30.4°; and the puncture angle of lumbar vertebrae in L1-L5 was from 28° to 35° with an average of 31.3°. Postoperative X-rays showed the area ratios of bilateral bone cement was 0.97 ± 0.15. Bilateral diffuse area were basic equal. Postoperative VAS score decreased significantly (1.89 ± 1.29 vs 7.03 ± 1.42). Through measure imaging data before operation with PKP,the puncture point and entry point can be confirmed. According the measured data to puncture during operation, unilateral puncture can reach the distribution effect of the bilateral puncture in the treatment of thoracolumbar compression fractures.

  8. There is room for improvement in the prevention and treatment of headache after lumbar puncture

    DEFF Research Database (Denmark)

    Stendell, Line; Fomsgaard, Jonna S; Olsen, Karsten S

    2012-01-01

    The incidence of post dural puncture headache (PDPH) after lumbar puncture (LP) can be reduced from 36% to 0-9% by use of an atraumatic needle size 24 gauge (G)/0.56 mm rather than a traumatic needle size 22 G/0.7 mm. The evidence supporting some of the prophylactic and therapeutically treatments...

  9. A new multiple noncontinuous puncture (pointage technique for corneal tattooing

    Directory of Open Access Journals (Sweden)

    Jin Hyoung Park

    2015-10-01

    Full Text Available AIM:To assess the safety and cosmetic efficacy of a new multiple noncontinuous transepithelial puncture technique for tattooing a decompensated cornea.METHODS:It was anon-comparative clinical case series study.The study examines 33 eyes in 33 patients with total corneal opacity due to corneal decompensation, which developed following intraocular surgery.Corneal tattooing was performed using the multiple noncontinuous transepithelial puncture technique (i.e. pointage. The safety of this new surgical strategy was assessed by occurrence of adverse events for the follow-up period. The cosmetic efficacy was determined by the patient’s cosmetic satisfaction and independent observer’s opinion about patient appearance.RESULTS:Seven women and 26 men were included in the study. The mean age was 46.4±17.5y (range:7-67. In total, 30 of 33 patients (91% reported cosmetic satisfaction within the follow-up period. Only 3 patients (9% required additional tattooing due to cosmetic unsatisfaction. Cosmetic outcomes were analyzed and classified as excellent or good in 13 (39% and 17 (52% patients, respectively. No serious adverse events developed, except delayed epithelial healing in 3 cases.CONCLUSION:The cosmetic outcomes of the multiple noncontinuous transepithelial puncture technique for corneal tattooing were good. The safety of this method is higher than conventional procedures. This new procedure also provides improved cost-effectiveness and safety over current corneal tattooing techniques.

  10. [Examination of the optimal midazolam dose required for loss of puncture memory at the time of spinal anesthesia].

    Science.gov (United States)

    Boku, Aiji; Koyama, Shinichi; Kishimoto, Naotaka; Nakatani, Keiji; Kurita, Satoshi; Nagata, Noboru; Niwa, Hitoshi

    2011-08-01

    We examined midazolam ED50 according to age that was necessary for loss of puncture memory at the time of spinal anesthesia and determined whether we could estimate the presence of puncture memory from the degree of sedation after midazolam administration. We enrolled patients with ASA PS 1 or 2 and patients from 50 to 80 years of age who had been planned for surgery with spinal anesthesia. We divided the patients into groups according to their age--50s, 60s, and 70s as L, M, and H groups, respectively. We evaluated the degree of sedation with six phases of scores after intravenous administration of midazolam and spinal anesthesia was performed. The midazolam dose was based on the ups and downs method. The midazolam ED50s required for the loss of puncture memory in groups L, M, and H were 0.043, 0.035, and 0.026 mg x kg(-1), respectively. We estimated the association between the sedation degree score after midazolam administration and the puncture memory from ROC curve, but AUC was 0.56 for all cases. The midazolam ED50 required for the loss of puncture memory decreased with age but it was difficult to estimate puncture memory from the degree of sedation.

  11. The optical "Veress-needle"--initial puncture with a minioptic.

    Science.gov (United States)

    Schaller, G; Kuenkel, M; Manegold, B C

    1995-02-01

    Laparoscopic access is a necessary part of minimally invasive surgery. The double blind puncture with Veress-needle and trocar can cause lethal complications such as bowel injury, bleeding and gas-embolisation. Some authors have reported alternative techniques for laparoscopic abdominal access. Because no blind procedure can absolutely prevent injury, permanent visual control of perforated tissue layers as in open surgery should be achieved to prevent possible injury at an early stage. Previously described procedures could not fulfil all requirements to comply with this ideal, i.e. permanent visual control of abdominal wall penetration prior to establishment of pneumoperitoneum and trocar insertion without further possible damage. We designed a 2 mm fibreglass optic 250 mm in length that is inserted into a suitable cannula. Special construction allows rinsing through the cannula to clear the vision and to open spaces in the puncture track by water dissection. After incision of the skin, all layers of the abdominal wall can be visualised, including blood vessels and internal surfaces. Once the abdominal cavity is reached, the needle tip is retracted and a two-step dilation allows the trocar to be introduced via the puncture track. Only then does insufflation begin. The fibreglass optic-equipped safety needle was used for visually controlled access in 184 laparoscopic surgical procedures. After a period of training, all layers of the abdominal wall could be recognised exactly. In two patients with dense adhesions, perforation of the small bowel was diagnosed immediately by endoscopic viewing. The small injury needed no treatment, and the intended procedure was completed laparoscopically.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch

    International Nuclear Information System (INIS)

    Ahn, Kyung-Sik; Yong, Hwan Seok; Woo, Ok Hee; Kang, Eun-Young; Lee, Joo-Won

    2007-01-01

    We present a rare case of right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch. A 7-month-old boy presented with a cardiac murmur. Cardiac situs was normal and there was no evidence of an intracardiac shunt or patent ductus arteriosus. MR aortography revealed a right aortic arch that was high-positioned, tortuous and narrowed. This right aortic arch crossed the midline behind the oesophagus and continued as a left-sided descending aorta. The left common carotid and subclavian arteries arose from a large branching vascular structure that derived from the top of the left-sided descending aorta. The right common carotid artery arose from the ascending aorta. The proximal portion of the right common carotid artery showed very severe stenosis and poststenotic dilatation. The right subclavian artery originated distal to the narrowed and tortuous segment of the aortic arch. (orig.)

  13. Comparison of dural puncture epidural technique versus conventional epidural technique for labor analgesia in primigravida

    Directory of Open Access Journals (Sweden)

    Pritam Yadav

    2018-01-01

    Full Text Available >Background: Dural puncture epidural (DPE is a method in which a dural hole is created prior to epidural injection. This study was planned to evaluate whether dural puncture improves onset and duration of labor analgesia when compared to conventional epidural technique.Methods and Materials: Sixty term primigravida parturients of ASA grade I and II were randomly assigned to two groups of 30 each (Group E for conventional epidural and Group DE for dural puncture epidural. In group E, epidural space was identified and 18-gauge multi-orifice catheter was threaded 5 cm into the epidural space. In group DE, dura was punctured using the combines spinal epidural (CSE spinal needle and epidural catheter threaded as in group E followed by 10 ml of injection of Ropivacaine (0.2% with 20 mcg of Fentanyl (2 mcg/ml in fractions of 2.5 ml. Later, Ropivacaine 10 ml was given as a top-up on patient request. Onset, visual analouge scale (VAS, sensory and motor block, haemodynamic variables, duration of analgesia of initial dose were noted along with mode of delivery and the neonatal outcome.Results: Six parturients in group DE achieved adequate analgesia in 5 minutes while none of those in group E (P 0.05.Conclusions: Both techniques of labor analgesia are efficacious; dural puncture epidural has the potential to fasten onset and improve quality of labor analgesia when compared with conventional epidural technique.

  14. Dysphagia lusorium in elderly: A case report

    Science.gov (United States)

    Kantarceken, Bulent; Bulbuloglu, Ertan; Yuksel, Murvet; Cetinkaya, Ali

    2004-01-01

    AIM: Late unset of dysphagia due to vascular abnormalities is a rare condition. We aimed to present a case of right subclavian artery abnormalities caused dysphagia in the elderly. METHODS: A 68-year-old female was admitted with dysphagia seven months ago. Upper endoscopic procedures and routine examinations could not demonstrate any etiology. Multislice computed thorax tomography was performed for probable extra- esophagial lesions. RESULTS: Multislice computed thorax tomography showed right subclavian artery abnormality and esophagial compression with this aberrant artery. CONCLUSION: Causes of dysphagia in the elderly are commonly malignancies, strictures and/or motility disorders. If routine examinations and endoscopic procedures fail to show any etiology, rare vascular abnormalities can be considered in such patients. Multislice computed tomography is a usefull choice in such conditions. PMID:15285045

  15. Usefulness of digital subtraction angiography in ischemic cerebral vascular disease: relationship to age and gender

    Energy Technology Data Exchange (ETDEWEB)

    Klein, U; Hall, D; Vogt, U

    1986-01-01

    In 500 consecutive patients, intravenous digital subtraction angiography of the extracerebral arteries was carried out. 63.2% of the patients were males, 36.8% females. A total of 37.4% of the patients were 59 years of age or less (69.5% male, 30.5% female). 62.6% were 60 years and older (59.5% male, 40.5% female). 30.6% of all patients were over the age of 70 years (51% male, 49.0% female). 54% of all patients had pathologic findings: of these, 67% were males and 33.0% females. In 56 patients (11.2%), the carotis bifurcation was not adequately visualized. Of 214 patients with lesions of the internal carotid artery, 59.3% had unilateral stenosis. Unilateral occlusion of the carotis was found in 18.7%, bilateral stenosis of the internal carotid artery as well as internal carotid stenosis with contralateral occlusion was found in 10.3%. Additional lesions in the remaining extracerebral vessels were found in 34.6% (stenosis or occlusion of the external carotid artery, vertebral arteries or the subclavian artery, including subclavian steal syndrome).

  16. Surgery for acute Type I aortic dissection without resection of supra-aortic entry sites leads to unfavourable aortic remodelling.

    Science.gov (United States)

    Heo, Woon; Song, Suk-Won; Lee, Kwang-Hun; Lee, Shin-Young; Kim, Tae-Hoon; Baek, Min-Young; Yoo, Kyung-Jong

    2018-01-29

    This study aimed to evaluate the impact of remnant re-entries in arch branches on postoperative change in the aortic arch and descending aortic diameters and the rate of major adverse aortic events. Between January 2010 and December 2016, 249 patients underwent surgery for acute Type I aortic dissection. Patients who underwent total arch replacement, had Marfan syndrome or had intramural haematoma were excluded. Seventy-two patients with predischarge and follow-up computed tomography scans were enrolled. Patients with and without re-entries in the arch branches after surgery were assigned to the supra-aortic entry (SAE, n = 21) and no supra-aortic entry (n = 51) groups, respectively. Diameters were measured at 7 levels: the innominate artery, left common carotid artery, left subclavian artery, 20 mm distal to the left subclavian artery, pulmonary artery bifurcation, coeliac axis and maximal diameter of the descending thoracic aorta. Growth rates at the levels of the pulmonary artery bifurcation and 20 mm distal to the left subclavian artery were significantly higher in the SAE group than in the no supra-aortic entry group. The rate of freedom from major adverse aortic events (annual growth >5 mm or maximal diameter of the descending thoracic aorta >50 mm) at 5 years was significantly higher in the no supra-aortic entry group than in the SAE group. Remnant SAE leads to unfavourable aortic remodelling after acute Type I aortic dissection repair. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  17. Influence of repetitive finger puncturing on skin perfusion and capillary blood analysis in patients with diabetes mellitus

    NARCIS (Netherlands)

    de Graaff, J. C.; Hemmes, G. J.; Bruin, T.; Ubbink, D. T.; Michels, R. P.; Jacobs, M. J.; Sanders, G. T.

    1999-01-01

    Frequent puncturing of fingers to check blood glucose in patients with type 1 diabetes might alter skin perfusion and, hence, influence the representativeness of the blood sample. We investigated the influence of repetitive puncturing on skin microcirculatory perfusion using laser Doppler fluxmetry

  18. A New Navigation System of Renal Puncture for Endoscopic Combined Intrarenal Surgery: Real-time Virtual Sonography-guided Renal Access.

    Science.gov (United States)

    Hamamoto, Shuzo; Unno, Rei; Taguchi, Kazumi; Ando, Ryosuke; Hamakawa, Takashi; Naiki, Taku; Okada, Shinsuke; Inoue, Takaaki; Okada, Atsushi; Kohri, Kenjiro; Yasui, Takahiro

    2017-11-01

    To evaluate the clinical utility of a new navigation technique for percutaneous renal puncture using real-time virtual sonography (RVS) during endoscopic combined intrarenal surgery. Thirty consecutive patients who underwent endoscopic combined intrarenal surgery for renal calculi, between April 2014 and July 2015, were divided into the RVS-guided puncture (RVS; n = 15) group and the ultrasonography-guided puncture (US; n = 15) group. In the RVS group, renal puncture was repeated until precise piercing of a papilla was achieved under direct endoscopic vision, using the RVS system to synchronize the real-time US image with the preoperative computed tomography image. In the US group, renal puncture was performed under US guidance only. In both groups, 2 urologists worked simultaneously to fragment the renal calculi after inserting the miniature percutaneous tract. The mean sizes of the renal calculi in the RVS and the US group were 33.5 and 30.5 mm, respectively. A lower mean number of puncture attempts until renal access through the calyx was needed for the RVS compared with the US group (1.6 vs 3.4 times, respectively; P = .001). The RVS group had a lower mean postoperative hemoglobin decrease (0.93 vs 1.39 g/dL, respectively; P = .04), but with no between-group differences with regard to operative time, tubeless rate, and stone-free rate. None of the patients in the RVS group experienced postoperative complications of a Clavien score ≥2, with 3 patients experiencing such complications in the US group. RVS-guided renal puncture was effective, with a lower incidence of bleeding-related complications compared with US-guided puncture. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. 40 CFR Table 3 to Subpart Xxxx of... - Emission Limits for Puncture Sealant Application Affected Sources

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Emission Limits for Puncture Sealant Application Affected Sources 3 Table 3 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 3 Table 3 to Subpart XXXX of Part 63—Emission Limits for Puncture...

  20. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Puncture Sealant Application Control Devices 4 Table 4 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 4 Table 4 to Subpart XXXX of Part 63—Operating Limits for Puncture...

  1. Ulnar Artery Compression: A Feasible and Effective Approach to Prevent the Radial Artery Occlusion after Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Jun Tian

    2015-01-01

    Full Text Available Background: Radial artery (RA occlusion (RAO is not rare in patients undergoing coronary intervention by transradial approach (TRCI. Predictors of and prevention from RAO have not been systematically studied. This study aimed to analyze the risk factors of the weakness of RA pulsation (RAP and its predictive value for RAO after TRCI, and simultaneously to describe a feasible and effective approach to maintain RA patency. Methods: Between June 2006 and March 2010, all patients who underwent TRCI were classified according to the weakness of RAP after removing compression bandage with confirmation by Doppler ultrasound for the first 30 consecutive patients. Among a total of 2658 patients studied, 187 (7% patients having a weaker RAP were prospectively monitored. At 1 h after bandage removal, the ulnar artery in puncture side of all patients was blocked with manual compression to favor brachial and collateral artery blood flow through the RA until a good RAP was restored. The primary analysis was the occurrence of RAO. Results: Doppler ultrasound demonstrated the significant reduction of both systolic velocity (61.24 ± 3.95 cm/s vs. 72.31 ± 3.57 cm/s and diastolic velocity (1.83 ± 0.32 cm/s vs. 17.77 ± 3.97 cm/s in RA at access side as compared to the contralateral RA (all P < 0.001, but these velocities in ipsilateral ulnar artery (81.2 ± 2.16 cm/s and 13.1 ± 2.86 cm/s, respectively increased profoundly. The average time of ulnar artery compression was 4.1 ± 1.2 h (ranged 2.5-6.5 h. There were two patients experienced persistent RAO with a success rate of 98.9% and RAO in 0.075% of patients after ulnar artery compression was applied. The pulsation of the ulnar artery after compression was removed had not been influenced by the compression. Conclusions: After intervention using TRCI approach, the presence of a weaker RAP is an indicator of imminent RAO. The continuing compression of ipsilateral ulnar artery is an effective approach to

  2. Bilateral Pneumothoraces Following Central Venous Cannulation

    OpenAIRE

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right ...

  3. CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial.

    Science.gov (United States)

    Kirchner, Johannes; Kickuth, Ralph; Laufer, Ulf; Schilling, Esther Maria; Adams, Stephan; Liermann, Dieter

    2002-03-01

    We investigated the benefit of real-time guidance of interventional punctures by means of computed tomography fluoroscopy (CTF) compared with the conventional sequential acquisition guidance. In a prospective randomized trial, 75 patients underwent either CTF-guided (group A, n = 50) or sequential CT-guided (group B, n = 25) punctures of thoracic (n = 29) or abdominal (n = 46) masses. CTF was performed on the CT machine (Somatom Plus 4 Power, Siemens Corp., Forchheim, Germany) equipped with the C.A.R.E. Vision application (tube voltage 120 kV, tube current 50 mA, rotational time 0.75 s, slice thickness 10 mm, 8 frames/s). The average procedure time showed a statistically significant difference between the two study groups (group A: 564 s, group B 795 s, P = 0.0032). The mean total mAs was 7089 mAs for the CTF and 4856 mAs for the sequential image-guided intervention, respectively. The sensitivity was 71% specificity 100% positive predictive value 100% and negative predictive value 60% for the CTF-guided puncture, and 68, 100, 100 and 50% for sequential CT, respectively. CTF guidance realizes a time-saving but increases the radiation exposure dosage.

  4. An evaluation of the Johnson-Cook model to simulate puncture of 7075 aluminum plates.

    Energy Technology Data Exchange (ETDEWEB)

    Corona, Edmundo; Orient, George Edgar

    2014-02-01

    The objective of this project was to evaluate the use of the Johnson-Cook strength and failure models in an adiabatic finite element model to simulate the puncture of 7075- T651 aluminum plates that were studied as part of an ASC L2 milestone by Corona et al (2012). The Johnson-Cook model parameters were determined from material test data. The results show a marked improvement, in particular in the calculated threshold velocity between no puncture and puncture, over those obtained in 2012. The threshold velocity calculated using a baseline model is just 4% higher than the mean value determined from experiment, in contrast to 60% in the 2012 predictions. Sensitivity studies showed that the threshold velocity predictions were improved by calibrating the relations between the equivalent plastic strain at failure and stress triaxiality, strain rate and temperature, as well as by the inclusion of adiabatic heating.

  5. Postpartum cortical venous thrombosis: An unusual presentation of postdural puncture headache

    Directory of Open Access Journals (Sweden)

    Opal Raj

    2016-01-01

    Full Text Available Headache is a common occurrence during pregnancy. A postural headache is invariably considered to be a postdural puncture headache in patients who receive neuraxial anesthesia with or without obvious or incidental dural puncture. Cerebral venous thrombosis (CVT is rare in pregnancy and in the postpartum period, with an incidence of 1:10,000–1:25,000. Pregnancy-induced changes in coagulation result in a hypercoagulable state, which may naturally reduce the incidence of postpartum hemorrhage, but may also increase the risk of CVT. Postpartum headache being frequently encountered may complicate the diagnosis of CVT. We report a case of a woman who developed a postpartum CVT after an accidental wet tap and intrathecal catheter placement during labor.

  6. On Railroad Tank Car Puncture Performance: Part I - Considering Metrics

    Science.gov (United States)

    2016-04-12

    This paper is the first in a two-part series on the puncture performance of railroad tank cars carrying hazardous materials in the event of an accident. Various metrics are often mentioned in the open literature to characterize the structural perform...

  7. On Railroad Tank Car Puncture Performance: Part II - Estimating Metrics

    Science.gov (United States)

    2016-04-12

    This paper is the second in a two-part series on the puncture performance of railroad tank cars carrying hazardous materials in the event of an accident. Various metrics are often mentioned in the open literature to characterize the structural perfor...

  8. Clinical application of percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation under CT guidance

    International Nuclear Information System (INIS)

    Wang Linyou; Li Yuan; Shao Yangtong

    2004-01-01

    Objective: To evaluate the effect of the percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation. Methods: 75 cases of lumbar disc herniation with significant clinical signs were confirmed by CT scan. The technique of the percutaneous lumbar puncture led the needle to approach nerve root and injected medicine diffusing into extraduramater, and then relieved the symptom of sciatica. Results: The rate of success of percutaneous lumbar puncture guided by CT reached to 100%. After two weeks of follow-up, the symptom of pain was obviously improved and disappeared in 63.3% cases. There were 23.0% cases needed a second procedure, and no change was obsesved in 9.3% cases. Conclusions: The percutaneous lumbar puncture guided by CT to treat sciatica resulted from lumbar disc herniation is one of the safe, reliable, effective new methods with no complication. The long term effectiveness is still in need of investigation. (authors)

  9. [Arterial involvements in hereditary dysplasia of the connective tissue].

    Science.gov (United States)

    Beylot, C; Doutre, M S; Beylot-Barry, M; Busquet, M

    1994-03-01

    Arterial involvement is an important feature of the diagnosis and, above all, prognosis of heritable disorders of connective tissue. In pseudoxanthoma elasticum, a progressive occlusive syndrome is associated with hemorrhage and especially with gastrointestinal bleeding. Aneurysms are uncommon. Hypertension occurs frequently. Cutaneous signs (yellowish pseudo xanthomatous papules of the large folds) the ocular changes (angioid streaks) and pathology showing numerous, thickened, fragmented, disorganized, calcified elastic fibers in the deep dermis and arterial walls, allow the diagnosis to be made. In the heterogeneous group of Ehlers-Danlos syndromes, type IV is characterized by sudden spontaneous rupture of the large arteries. Aneurysms and carotido-cavernous fistulae are rather frequent. Owing to friability of the arterial walls, arteriograms and other procedure requiring arterial puncture may prove hazardous and surgery difficult. Such patients have an acrogeric morphotype, and thin, fragile skin, but cutaneous hyperelasticity and joint hyperlaxity are usually minimal. Pathology evidences collagen hypoplasia in the skin and arterial walls. The severity of Marfan syndrome is due to aortic involvement. A fusiform aneurysm of the ascending aorta represents a vital risk of rupture. Aortic root dilatation is associated and responsible of severe aortic regurgitation. Aortic dissection is also a serious threat. Improved surgical techniques for repairing a dilated or dissected aortic root with simultaneous replacement of the aortic valve increases the life expectancy of such patients. Dolichomorphism is the characteristic skeletal abnormality, particularly with arachnodactyly and upward ectopia lentis, which is almost bilateral, is a very frequent feature of Marfan syndrome. The most typical histological finding is aortic cystic median necrosis. The basic defect in Marfan syndrome concerns the fibrillin, whose gene is located on chromosome 15. The three diseases

  10. Spinal Ischemia in Thoracic Aortic Procedures: Impact of Radiculomedullary Artery Distribution.

    Science.gov (United States)

    Kari, Fabian A; Wittmann, Karin; Krause, Sonja; Saravi, Babak; Puttfarcken, Luisa; Förster, Katharina; Rylski, Bartosz; Maier, Sven; Göbel, Ulrich; Siepe, Matthias; Czerny, Martin; Beyersdorf, Friedhelm

    2017-12-01

    The aim of this study was to assess the influence of thoracic anterior radiculomedullary artery (tARMA) distribution on spinal cord perfusion in a thoracic aortic surgical model. Twenty-six pigs (34 ± 3 kg; study group, n = 20; sham group, n = 6) underwent ligation of the left subclavian artery and thoracic segmental arteries. End points were spinal cord perfusion pressure (SCPP), regional spinal cord blood flow (SCBF), and neurologic outcome with an observation time of 3 hours. tARMA distribution patterns tested for an effect on end points included (1) maximum distance between any 2 tARMAs within the treated aortic segment (0 or 1 segment = small-distance group; >1 segment = large-distance group) and (2) distance between the end of the treated aortic segment and the first distal tARMA (at the level of the distal simulated stent-graft end = group 0; gap of 1 or more segments = group ≥1). The number of tARMA ranged from 3 to 13 (mean, 8). In the large-distance group, SCBF dropped from 0.48 ± 0.16 mL/g/min to 0.3 ± 0.08 mL/g/min (p distribution patterns of tARMAs correlate with the degree of SCBF drop and insufficient reactive parenchymal hyperemia in aortic procedures. Individual ARMA distribution patterns along the treated aortic segment could help us predict the individual risk of spinal ischemia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. A case of subdural hematoma following lumbar puncture

    Directory of Open Access Journals (Sweden)

    Ramatharaknath Vemuri

    2017-01-01

    Full Text Available Lumbar puncture (LP is a frequent procedure done for administration of spinal anesthesia or for obtaining cerebrospinal fluid for analysis. The common complications of LP are pain at the local site and headache. Fortunately, the serious complications such as infections of central nervous system, brain stem herniation, and subdural hematoma are rare. We present a rare case of subdural hematoma following a LP.

  12. Large mobile thrombus in non-atherosclerotic thoracic aorta as the source of peripheral arterial embolism

    Directory of Open Access Journals (Sweden)

    Brkovic Zoran

    2005-11-01

    Full Text Available Abstract The presence of thrombi in the atherosclerotic and/or aneurysmatic aorta with peripheral arterial embolism is a common scenario. Thrombus formation in a morphologically normal aorta, however, is a rare event. A 50 years old woman was admitted to the mergency department for pain, coldness, and anesthesia in the the left foot. She had a 25 years history of cigarette smoking, a history of postmenopausal hormone replacement therapy (HRT, hypercholesterolemia and hyperfibrinogenemia. An extensive serologic survey for hypercoagulability, including antiphospholipid antibodies, and vasculitis disorders was negative. Transesophageal echocardiography revealed a large, pedunculated and hypermobile thrombus attached to the aortic wall 5 cm distal of the left subclavian artery. The patient was admitted to the surgery department, where a 15 cm long fresh, parietal thrombus could be removed from the aorta showing no macroscopic wall lesions or any other morphologic abnormalities. This case report demonstrates the possibility of evolving a large, pedunculated thrombus in a morphologically intact aorta in a postmenopausal woman with thrombogenic conditions such as hyperfibrinogenemia, hypercholesterolemia, smoking and HRT. For these patients, profiling the individual risk and weighing the benefits against the potential risks is warranted before prescribing HRT.

  13. Study of DSA-guided percutaneous puncture location of foramen oval

    International Nuclear Information System (INIS)

    Zhao Xiaojun; He Jiawei; Bai Guanghui; Shi Jianjing; Xu Chongyong; Zhan Gonghao

    2008-01-01

    Objective: To study the technique of digital substraction angiography (DSA)-guided percutaneous puncture location of foramen oval. Methods: 39 cases of trigeminal neuralgia were included in the study from Feb. 2004 to Oct. 2006. The patients were punctured by the amending anterior position. The f0ramen oval was displayed by moving the tube tilted 20-28 degree to the caudal and 16-23 degree to the healthy side. The direction and depth of the needles was determined on the lateral view. Then, radio-frequency thermocoagulation therapy was performed. Results: The needles were located in oval foramen in all the patients. Pain disappeared in 36 cases, alleviated in other cases, and no serious complication occurred during therapy. Conclusions: Oval foramen locations by DSA can improve the successful rate of operation. The foramen oval can be clearly displayed by DSA-guided in amending position, with comfortable position for patients. (authors)

  14. Aggressive treatment of idiopathic axillo-subclavian vein thrombosis provides excellent long-term function.

    Science.gov (United States)

    Stone, David H; Scali, Salvatore T; Bjerk, Aja A; Rzucidlo, Eva; Chang, Catherine K; Goodney, Philip P; Nolan, Brian W; Walsh, Daniel B

    2010-07-01

    While much attention has been devoted toward treatment paradigms for idiopathic axillo-subclavian vein thrombosis (ASVT), little has focused on long-term durability of aggressive treatment and its associated functional outcomes. The purpose of this study was to review our own surgical therapeutic algorithm and its associated durability and functional outcomes. All patients treated with combined endovascular and open surgery at Dartmouth-Hitchcock Medical Center for ASVT from 1988 to 2008 were identified. Patient demographics, comorbidities, and operative techniques were recorded. Patency, freedom from reintervention, and functional outcomes were documented. Follow-up via telephone and clinic visit allowed quantitative comparison of functional status, pre- and postoperatively. Thirty-six patients were treated for ASVT throughout the study interval. Seven patients (19.4%) were lost to follow-up. Most patients were male (66%; N = 24); mean age was 32 years. Catheter-directed thrombolysis was utilized in the majority of patients (83.3%; N = 30) with an average time from symptom onset to lysis of 12 days. Surgical decompression was undertaken in all patients via transaxillary (52%; N = 19), supraclavicular (31%; N = 11), or infraclavicular approaches (17%; N = 6). Eleven stents were placed in 11 patients (30.5%) for residual stenotic disease. Mean follow-up was 65 months, with 1- and 5-year overall patency at 100% and 94%, respectively. Freedom from reintervention was 100% and 74.4% at 1 and 5 years, respectively. Seven patients (19.4%) required postoperative reintervention with four receiving additional lytic therapy, two requiring a stent, and one venoplasty. At presentation, 65.5% (N = 19) of patients were unable to work or perform routine activities. After treatment, 86% (N = 25) returned to their employment and have experienced sustained symptomatic and functional improvement. Patients with symptomatic idiopathic axillo-subclavian vein thrombosis can expect durable

  15. A New Ultrasound-Guided Puncture Device with Augmented Degrees of Performance Freedom and Ability to Attach to Most Convex Probes

    International Nuclear Information System (INIS)

    Jung, Sung Il; Son, Kyu Ri; Kim, Young Jun; Jeon, Hae Jeong; Park, Sang Woo; Cho, Jeong Yeon; Kim, Seung Hyup

    2008-01-01

    To evaluate the performance of a newly-designed ultrasound (US)-guided puncture device. A newly-designed US-guided puncture device was composed of a guide segment and an attachable segment. The guide segment allowed the needle to be placed in the plane of US view with a maximal degree of freedom, and the attachable segment was designed to attach to most convex US probes. Six operators punctured 144 targets in phantoms using either the new device (n = 72) or free-hand technique (n = 72). The number of required needle passages and the necessary procedure times were compared between the two groups. The number of required needle passages and the necessary procedure time were significantly reduced in five operators when the newly-designed US-guided puncture device was used (p < 0.05). A newly-designed US-guided puncture device, which allows for a maximal degree of freedom in needle placement and can attach to most convex US probes, showed good performance in our study

  16. Clinical observation of intraluminal stent angioplasty in the treatment of renal arterial stenoses

    International Nuclear Information System (INIS)

    Lu Yanwen; Zhang Jian; Huang Xianglong

    2002-01-01

    Objective: To evaluate the clinical application of intraluminal stent angioplasty (PTRAS) in the treatment of renal arterial stenoses. Methods: A retrospective study was done in 28 patients with renal arterial stenoses. Primary renal artery stenting was performed in 28 consecutive patients (36 renal arteries). Blood pressure, serum creating, the number of anti-hypertensive medications were recorded at 1, 6, 12 month post stent angioplasty respectively. Arterial angiography was also taken 1 year later to evaluate the incidence of restenosis. Results: Technical success rate was 100% achieving in all patients without serious complications. Primary successful patently rate reached 82% (renal artery 86%), secondary successful rate was 89% (renal artery 90%). Systolic and diastolic blood pressure were reduced significantly (P<0.01) at 1,6,12 month after stent angioplasty comparing with baseline and clinical improvement (cured + improved) of hypertension reached 100%, 92.9%, 89.3% respectively. There were no significant differences between serum creatine level and the number of anti-hypertensive medications before and after stent angioplasty. One year later, 14.3% of all patients showed improvement of renal function, 64.3% remained in stabilization and 21.4% fell into deterioration. Angiographic restenosis was found in 3 cases one year after stent angioplasty. Complications included 1 hematoma at puncture site and 3 transient azotaemia. Conclusions: PTRAS can be performed safely with high technical success and beneficial to the majority of patients with hypertension or renal insufficiency and therefore it should be the first choice in treating renal arterial stenoses

  17. Ovarian Artery Embolization in Patients With Collateral Supply to Symptomatic Uterine Leiomyomata

    International Nuclear Information System (INIS)

    Scheurig-Muenkler, C.; Poellinger, A.; Wagner, M.; Hamm, B.; Kroencke, T. J.

    2011-01-01

    Purpose: To evaluate the safety and outcome of ovarian artery embolization (OAE) in patients with collateral supply to symptomatic uterine leiomyomata. Materials and Methods: Thirteen patients with relevant leiomyoma perfusion by way of enlarged ovarian arteries underwent additional OAE during the same (N = 10) or a second procedure (N = 3). Uterine artery embolization (UAE) was performed bilaterally in 10 and unilaterally in 2 patients with a single artery. One patient had no typical uterine arteries but bilaterally enlarged ovarian arteries, prompting bilateral OAE. OAE was accomplished with coil embolization in one and particle embolization in 12 patients. Symptoms before therapy and clinical outcome were assessed using a standardized questionnaire. Contrast-enhanced magnetic resonance (MR) imaging after embolization was available in 11 of 13 patients and was used to determine the percentage of fibroid infarction. Results: UAE and OAE were technically successful in all patients. One patient experienced prolonged irritation at the puncture site. Median clinical follow-up time was 16 months (range 4–37). Ten of 13 patients showed improvement or complete resolution of clinical symptoms. One patient reported only slight improvement of her symptoms. These women presented with regular menses. Two patients (15%), 47 and 48 years, both with unilateral OAE, reported permanent amenorrhea directly after embolization. Their symptoms completely resolved. Seven patients showed complete and 4 showed >90% fibroid infarction after embolization therapy. Conclusions: OAE is technically safe and effective in patients with ovarian artery collateral supply to symptomatic uterine leiomyomata. The risk of permanent amenorrhea observed in this study is similar to the reported incidence after UAE.

  18. Consensus guidelines for lumbar puncture in patients with neurological diseases

    NARCIS (Netherlands)

    S. Engelborghs (Sebastiaan); Niemantsverdriet, E. (Ellis); H. Struyfs (Hanne); K. Blennow (Kaj); Brouns, R. (Raf); M. Comabella (Manuel); I. Dujmovic (Irena); W.M. van der Flier (Wiesje); L. Frölich (Lutz); D. Galimberti (Daniela); S. Gnanapavan (Sharmilee); B. Hemmer` (Bernhard); E.I. Hoff (Erik I.); Hort, J. (Jakub); E. Iacobaeus (Ellen); M. Ingelsson (Martin); Jan de Jong, F. (Frank); Jonsson, M. (Michael); M. Khalil (Michael); J. Kuhle (Jens); A. Lleo (Alberto); A. De Mendonça (Alexandre); J.L. Molinuevo (José Luis); G. Nagels (Guy); C. Paquet (Claire); L. Parnetti; C.M.A.A. Roks (Gerwin); Rosa-Neto, P. (Pedro); P. Scheltens (Philip); C. Skarsgård (Constance); E. Stomrud (Erik); H. Tumani (Hayrettin); P. Visser (Pim); Wallin, A. (Anders); B. Winblad; H. Zetterberg (Henrik); F.H. Duits (Flora H.); C.E. Teunissen (Charlotte)

    2017-01-01

    textabstractIntroduction Cerebrospinal fluid collection by lumbar puncture (LP) is performed in the diagnostic workup of several neurological brain diseases. Reluctance to perform the procedure is among others due to a lack of standards and guidelines to minimize the risk of complications, such as

  19. Complications of lumbar puncture in a child treated for leukaemia

    International Nuclear Information System (INIS)

    Staebler, Melanie; Delpierre, Isabelle; Damry, Nash; Christophe, Catherine; Azzi, Nadira; Sekhara, Tayeb

    2005-01-01

    Lumbar puncture may lead to neurological complications. These include intracranial hypotension, cervical epidural haematomas, and cranial and lumbar subdural haematomas. MRI is the modality of choice to diagnose these complications. This report documents MRI findings of such complications in a child treated for leukaemia. (orig.)

  20. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance.

    Science.gov (United States)

    Zolnierczyk, Piotr; Cendrowski, Krzysztof; Sawicki, Wlodzimierz

    2015-01-01

    This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index - 38), congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic-therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations.

  1. Hypogastric Arterial Selective and Superselective Embolization for Severe Postpartum Hemorrhage: A Retrospective Review of 36 Cases

    International Nuclear Information System (INIS)

    Boulleret, C.; Chahid, T.; Gallot, D.; Mofid, R.; Tran Hai, D.; Ravel, A.; Garcier, J.M.; Lemery, D.; Boyer, L.

    2004-01-01

    We report on embolization in 36 cases of postpartum hemorrhage (PPH). The 36 patients with severe PPH, including one patient who had undergone an emergency hysterectomy, were transferred to the regional interventional vascular radiology unit in a mean time of 6 hours 12 min. Bilateral occlusion of the anterior trunk of the hypogastric arteries was carried out using gelatin sponge. Immediate success was achieved in all cases. In 3 cases, however, a second embolization was necessary before day 2. In 17%, complementary nonvascular surgery was performed. Complications included one puncture site false aneurysm treated by compression, two cases of regressive lower limb paraesthesia, one femoral vein thrombosis, and nonsignificant puncture site hematomas (19.5%). Long-term follow-up was conducted in 23 patients: 91% resumed regular menstrual cycles, 8.7% dysmenorrhea. New pregnancy occurred in 13% (two full-term pregnancies and one voluntary termination). Immediate efficacy, low morbidity and preservation of fertility make embolization the technique of choice for severe PPH

  2. Extra-Thoracic Supra-aortic Bypass Surgery Is Safe in Thoracic Endovascular Aortic Repair and Arterial Occlusive Disease Treatment.

    Science.gov (United States)

    Gombert, Alexander; van Issum, Lea; Barbati, Mohammad E; Grommes, Jochen; Keszei, Andras; Kotelis, Drosos; Jalaie, Houman; Greiner, Andreas; Jacobs, Michael J; Kalder, Johannes

    2018-04-20

    The safety and feasibility of supra-aortic debranching as part of endovascular aortic surgery or as a treatment option for arterial occlusive disease (AOD) remains controversial. The aim of this study was to assess the clinical outcome of this surgery. This single centre, retrospective study included 107 patients (mean age 69.2 years, 38.4% women) who underwent supra-aortic bypass surgery (carotid-subclavian bypass, carotid-carotid bypass, and carotid-carotid-subclavian bypass) because of thoracic or thoraco-abdominal endovascular aortic repair (57%; 61/107) or as AOD treatment (42.9%; 46/107) between January 2006 and January 2015. Mortality, morbidity with a focus on neurological complications, and patency rate were assessed. Twenty-six of 107 (14.2%) of the debranching patients were treated under emergency conditions because of acute type B dissection or symptomatic aneurysm. Follow up, conducted by imaging interpretation and telephone interviews, continued till March 2017 (mean 42.1, 0-125, months). The in hospital mortality rate was 10.2% (11/107), all of these cases from the debranching group and related to emergency procedures (p supra-aortic bypass surgery involves low complication rates and high mid-term bypass patency rates. It is a safe and feasible treatment option in the form of debranching in combination with endovascular aortic aneurysm repair and in AOD. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  3. Simulation and training of lumbar punctures using haptic volume rendering and a 6DOF haptic device

    Science.gov (United States)

    Färber, Matthias; Heller, Julika; Handels, Heinz

    2007-03-01

    The lumbar puncture is performed by inserting a needle into the spinal chord of the patient to inject medicaments or to extract liquor. The training of this procedure is usually done on the patient guided by experienced supervisors. A virtual reality lumbar puncture simulator has been developed in order to minimize the training costs and the patient's risk. We use a haptic device with six degrees of freedom (6DOF) to feedback forces that resist needle insertion and rotation. An improved haptic volume rendering approach is used to calculate the forces. This approach makes use of label data of relevant structures like skin, bone, muscles or fat and original CT data that contributes information about image structures that can not be segmented. A real-time 3D visualization with optional stereo view shows the punctured region. 2D visualizations of orthogonal slices enable a detailed impression of the anatomical context. The input data consisting of CT and label data and surface models of relevant structures is defined in an XML file together with haptic rendering and visualization parameters. In a first evaluation the visible human male data has been used to generate a virtual training body. Several users with different medical experience tested the lumbar puncture trainer. The simulator gives a good haptic and visual impression of the needle insertion and the haptic volume rendering technique enables the feeling of unsegmented structures. Especially, the restriction of transversal needle movement together with rotation constraints enabled by the 6DOF device facilitate a realistic puncture simulation.

  4. Endovascular Embolization of Bronchial Artery Originating from the Upper Portion of Aortic Arch in Patients with Massive Hemoptysis

    International Nuclear Information System (INIS)

    Jiang, Sen; Sun, Xi-Wen; Yu, Dong; Jie, Bing

    2014-01-01

    PurposeOur experience with endovascular embolization (EVE) of the bronchial artery (BA) originating from the upper portion of the aortic arch (AA) in six patients is described.MethodsAltogether, 818 patients with hemoptysis underwent multidetector row computed tomography angiography (MDCTA) before EVE or AA angiography during EVE. Aberrant BAs originating from the upper portion of the AA were the source of massive hemoptysis in six patients (0.73 %). MDCT angiograms and/or Digital subtraction angiograms were retrospectively reviewed. Selective catheterization and embolization were performed.ResultsThe ostia of the BAs were located on the superior surface of the AA between the brachiocephalic trunk and left common carotid artery in three patients, the junction of the aorta and medial surface of the left subclavian artery in two, and the posterior wall of the upper portion of the AA in one. The six BAs comprised two common trunks, three single right sides, and one single left side. The targeted vessels were successfully catheterized and embolized by a coaxial microcatheter system using polyvinyl alcohol particles. Other pathologic BAs and nonbronchial systemic arteries also were embolized. Bleeding was immediately controlled in all patients with no recurrence of hemoptysis. No procedure-related complications occurred.ConclusionsApplication of EVE of anomalous origin of BAs in patients with hemoptysis is important, as demonstrated in the six reported patients. MDCTA before EVE or AA angiography during EVE is critical to avoid missing a rare aberrant BA originating from the upper portion of the AA

  5. The effect of lung deflation on the position of the pleura during subclavian vein cannulation in infants receiving mechanical ventilation: an ultrasound study.

    Science.gov (United States)

    Jang, Y-E; Lee, J-H; Park, Y-H; Byon, H-J; Kim, H-S; Kim, C-S; Kim, J-T

    2013-10-01

    We evaluated the effect of lung deflation on the relative position of the pleura compared with a reference line during supra- and infraclavicular approaches to the right subclavian vein. The reference line was drawn relative to the predicted pathway of the needle. The distances between the pleura and the reference line for supra- and infraclavicular approaches were measured during inspiration and expiration in 41 infants. Measurements were repeated with the application of 5 cmH2O positive end-expiratory pressure (PEEP) and in the Trendelenburg position. Lung deflation during the supraclavicular approach significantly decreased the volume of lung crossing the reference line by a median (IQR [range]) of 1.0 (0.6 to 1.3 [0.0 to 4.8]) mm, p deflation showed no change in the distance of the pleura from the reference line regardless of PEEP or patient position. We conclude that lung deflation moves the lung apex caudally and can reduce the potential risk of pneumothorax during a supraclavicular approach to the right subclavian vein in infants. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  6. Ultrasound evaluation of forearm arteries in patients undergoing percutaneous coronary intervention via radial artery access: results of one-year follow-up.

    Science.gov (United States)

    Peruga, Jan Przemysław; Peruga, Jan Zbigniew; Kasprzak, Jarosław D; Kręcki, Radosław; Jankowski, Łukasz; Zając, Piotr; Plewka, Michał

    2015-01-01

    A proven advantage of radial over femoral arterial access has led to an increase in the number of interventions performed via radial artery access in patients with acute coronary syndromes. Both assessment of the pulse volume and the Allen's test are subjective and subject to investigator bias. An ultrasound examination of the forearm arteries provides important information about the anatomy of the forearm vessels, and indirectly also about the efficiency of collateral blood supply to the hand. It also enables determination of the relevant vessel diameter before the planned intervention, and may be used to assess local complications. To assess the morphology of forearm blood vessels and measure the diameter of both radial and ulnar arteries at the cannulation site using ultrasound imaging. We also aimed to identify potential vascular anomalies and local complications associated with radial artery puncture. The study included 109 patients with cardiologic indications for coronary angiography or coronary angioplasty. An ultrasound evaluation of forearm arteries was performed prior to the intervention, and the vascular anatomy was later verified by angiography during the procedure. Ultrasound measurements of the vessel diameter were also performed and local complications of the cannulation were assessed. Measurements were performed immediately after the procedure and at 30 days and 12 months. Fifty-nine right and 50 left forearm arteries were evaluated. Women were 29% of the study population. The mean patient age was 59.2 ± 7.9 years. The mean diameter of the right radial artery was 2.17 ± 0.54 mm, and the mean diameter of the left radial artery was 2.25 ± 0.43 mm. The measurements revealed gender-related differences in forearm artery diameter (p = 0.003). Vascular anomalies of the radial artery were identified by ultrasound examination in 10% of subjects. A significant dilatation of the cannulated blood vessel was observed which lasted up to 12 months. An

  7. Effectiveness of combined laser-puncture and conventional wound care to accelerate diabetic foot ulcer healing

    Directory of Open Access Journals (Sweden)

    Adiningsih Srilestari

    2017-05-01

    Full Text Available Background: Impaired wound healing is a common complication of diabetes. It has complex pathophysiologic mechanisms and often necessitates amputation. Our study aimed to evaluate the effectiveness of combined laser-puncture and conventional wound care in the treatment of diabetic foot ulcers.Methods: This was a double-blind controlled randomized clinical trial on 36 patients, conducted at the Metabolic Endocrine Outpatient Clinic, Cipto Mangunkusumo Hospital, Jakarta, between May and August 2015. Stimulation by laser-puncture (the treatment group or sham stimulation (the control group were performed on top of the standard wound care. Laser-puncture or sham were done on several acupuncture points i.e. LI4 Hegu, ST36 Zusanli, SP6 Sanyinjiao and KI3 Taixi bilaterally, combined with irradiation on the ulcers itself twice a week for four weeks. The mean reduction in ulcer sizes (week 2–1, week 3–1, week 4–1 were measured every week and compared between the two groups and analyzed by Mann-Whitney test.Results: The initial median ulcer size were 4.75 (0.10–9.94 cm2 and 2.33 (0.90–9.88 cm2 in laser-puncture and sham groups, respectively (p=0.027. The median reduction of ulcer size at week 2–1 was -1.079 (-3.25 to -0.09 vs -0.36 (-0.81 to -1.47 cm2, (p=0.000; at week 3–1 was -1.70 (-3.15 to -0.01 vs -0.36 (-0.80 to -0.28 cm2, (p=0.000; and at week 4–1 was -1.22 (-2.72 to 0.00 vs -0.38 (-0.74 to -0.57 cm2, (p=0.012.Conclusion: Combined laser-puncture and conventional wound care treatment are effective in accelerating the healing of diabetic foot ulcer.

  8. Twenty-Seven Years Experience With Transvenous Pacemaker Implantation in Children Weighing <10 kg.

    Science.gov (United States)

    Konta, Laura; Chubb, Mark Henry; Bostock, Julian; Rogers, Jan; Rosenthal, Eric

    2016-02-01

    Epicardial pacemaker implantation is the favored approach in children weighing pacemaker implantation in neonates and infants from 1987. To date there have been no long-term follow-up reports of what is for many a controversial strategy. Between 1987 and 2003, 37 neonates and infants-median age 6.7 months (1 day to 3 years) and median weight 4.6 kg (2.7-10 kg)-had a permanent transvenous pacing system implanted. Pacing leads were placed into the right ventricular apex/outflow tract through a subclavian vein puncture with a redundant loop in the atrium. Three patients were lost to follow-up, 4 patients died from complications of cardiac surgery, and 2 patients had their system removed. At long-term follow-up in 28 patients at a median of 17.2 (range, 11.2-27.4) years, 10 patients have a single chamber ventricular pacemaker, 14 a dual chamber pacemaker, 3 a biventricular pacemaker, and 1 has a single chamber implantable cardioverter defibrillator. Subclavian vein patency was assessed in 26 patients. The overall subclavian vein occlusion rate was 10 of 13 (77%) 5 kg during long-term follow-up. After a median of 14.3 (range, 13.4-17.6) years of pacing, 7 patients continue with their original lead. Transvenous pacing in infants <10 kg results in encouraging short- and long-term clinical outcomes. Subclavian vein occlusion remains an important complication, occurring predominantly in those weighing <5 kg. © 2016 American Heart Association, Inc.

  9. SAJS SAJS

    African Journals Online (AJOL)

    2009-07-20

    Jul 20, 2009 ... No. Other injuries. No. Arteries. 28. Pharynx. 5. Common carotid. 3. Oesophagus. 9. External carotid. 2. Larynx. 9. Internal carotid. 1. Trachea. 11. Subclavian. 2. Nerves. 13. Superior thyroid. 3. Recurrent laryngeal. 1. Vertebral. 2. Spinal cord. 6. Thyrocervical. 2. Spinal accessory. 1. Minor arteries. 13. Facial.

  10. Effect of needle puncture and electro-acupuncture on mucociliary clearance in anesthetized quails

    Directory of Open Access Journals (Sweden)

    Wang Tianshan

    2006-02-01

    Full Text Available Abstract Background Acupuncture therapy for obstructive respiratory diseases has been effectively used in clinical practice and the acupuncture points or acupoints of Zhongfu and Tiantu are commonly-used acupoints to treat patients with the diseases. Since the impaired mucociliary clearance is among the most important features of airway inflammation in most obstructive respiratory diseases, the effect of needle puncture and electro-acupuncture at the specific acupoints on tracheal mucociliary clearance was investigated in anesthetized quails. Methods Mucociliary transport velocity on tracheal mucosa was measured through observing the optimal pathway, and fucose and protein contents in tracheal lavages were determined with biochemical methods. In the therapeutic group, needle puncture or electro-acupuncture stimulation to the acupoints was applied without or with constant current output in 2 mA and at frequency of 100 Hz for 60 minutes. In the sham group, electro-acupuncture stimulation to Liangmen was applied. Results Our present experiments demonstrated that the electro-acupuncture stimulation to Zhongfu and Tiantu significantly increased tracheal mucociliary transport velocity and decreased the content of protein in the tracheal lavage, compared with the control group. Moreover, either needle puncture or electro-acupuncture stimulation to Zhongfu and Tiantu significantly reverted the human neutrophil elastase-induced decrease in tracheal mucociliary transport velocity and human neutrophil elastase -induced increase in the contents of fucose and protein in the tracheal lavage, compared with the control group. Conclusion These results suggest that either needle puncture or electro-acupuncture stimulation to the effective acupoints significantly improves both airway mucociliary clearance and the airway surface liquid and that the improvements maybe ascribed to both the special function of the points and the substantial stimulation of electricity.

  11. Puncture resistance of Type B transport systems

    International Nuclear Information System (INIS)

    Rack, H.J.; Cheresh, M.C.

    1980-01-01

    This report describes a recent attempt to develop a test method for use in screening materials and for evaluating the effects of certain parameters, for example section stiffness, on container penetration resistance. In addition, it illustrates the application of this procedure to the selection of a sheet steel for a transuranic waste (TRUPACT) container. The test consists of penetrating a specimen, normally 0.6 m square, with a punch (tup) attached to a falling weight and recording and analyzing the force-time history to determine the energy absorption during the impact event. The test as developed simulates certain aspects of the 10CFR71 drop test in order to provide a means of comparing, for example, the penetrating resistance of various steels, this resistance being defined as the energy required to initiate fracture in the specimen. In summary, this examination suggests that it should be possible to develop a laboratory test to rank and select materials for maximum puncture resistance. Although the initial results appear promising, more effort will be required before this procedure can be routinely applied to examining the various factors which control the puncture resistance of these materials. These results do, nonetheless, show that high-strength, low-alloy steels do offer significant advantages over mild steel for container penetration protection. Indeed, one of these steels, NAX-80, is presently considered as a prime candidate for the TRUPACT container being developed at Sandia National Laboratories

  12. Primary stent placement for recanalization of iliac artery occlusions: Using a self-expanding spiral stent

    International Nuclear Information System (INIS)

    Kim, Jae-Kyu; Kim, Yun-Hyeon; Chung, Sang-Yeung; Kang, Heoung-Keun

    1999-01-01

    Purpose: To report the clinical results for recanalizations of an occluded iliac artery by a self-expanding spiral stent.Methods: We attempted to recanalize 36 iliac artery occlusions in 34 patients [33 men, 1 woman, aged 51-75 years (average 61.6 years)]. The average lesion length was 6.92 cm (range 1-14 cm). The patients's chief complaints were intermittent claudication and resting pain. Fontaine classification was assigned before and after the procedure. Technical and clinical success were also analyzed.Results: Forty-five stents were successfully deployed in 34 patients. All 36 lesions (13 in the external iliac artery, 12 in the common iliac artery, and 11 in both) were patently recanalized on angiography. The follow-up period ranged from 6 months to 36 months (mean 11.9 months). Fourteen stents (39%) with incomplete expansion were dilated with a balloon catheter. Good technical (100%) and clinical (94%) results were obtained. The only complication was one hematoma at the puncture site. Reocclusions were noted in two lesions (5%) at 1 week and 15 months, respectively.Conclusion: A self-expanding spiral stent is a safe and effective device for recanalization of an iliac artery occlusion as the primary stent without any previous intervention.

  13. Usefulness of modified intravenous analgesia: initial experience in uterine artery embolization for leiomyomata

    International Nuclear Information System (INIS)

    Yang, Seung Boo; Jung, Young Jin; Goo, Dong Erk; Jang, Yun Woo

    2006-01-01

    We wanted to evaluate the usefulness of modified intravenous analgesia for the management of pain during uterine artery embolization for leiomyomata. Between April 2004 and July 2004, 15 patients with symptomatic fibroids underwent uterine artery embolization and pain management. Except the three patients for whom the Visual Analogue Scale (VAS) score was not obtained, twelve patients were included in this study. For pain management, epidural PCA (Patient Controlled Analgesia) was used in two patients, intravenous PCA was used in two patients and modified intravenous analgesia injection was used in eight patients. For all the patients, we used the 2.8 Fr coaxial microcatheter and 500-710 μ m PVA particles for the embolic materials. The protocol of the modified intravenous analgesia injection was as follow, 1) prior to femoral artery puncture, 30 mg of ketorolac tromethamine (Tarasyn)was injected via an intravenous route. 2) At the time that the one side uterine artery embolization was finished, normal saline mixed 150 mg meperidine (Demerol) was administered through the side port of the intravenous line that was used for hydration. 3) Additional ketorolac tromethamine 30 mg was injected after 6 hour. The VAS score and side effects were then checked. After 12 hours, the VAS score was rechecked. If the VAS score was above 4, this was considered as failure of pain management. The VAS scores, complications and side effects for the modified intravenous analgesia injection were compared with that of IV PCA and epidural PCA. The average VAS score of the modified intravenous analgesia injection, intravenous PCA and epidural PCA was 1.4, 1 and 0, respectively; the number of additional intramuscular injections of analgesia was 0.5, 0.5 and 0, respectively. All the patients who underwent epidural PCA had back pain at the puncture site and 1 patient who underwent modified intravenous analgesia injection experienced mild dyspnea, but they easily recovered with such

  14. Usefulness of modified intravenous analgesia: initial experience in uterine artery embolization for leiomyomata

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Boo; Jung, Young Jin [Soonchunhyang University, Gumi Hospital, Gumi (Korea, Republic of); Goo, Dong Erk; Jang, Yun Woo [Soonchunhyang University Hospital, Seoul (Korea, Republic of)

    2006-04-15

    We wanted to evaluate the usefulness of modified intravenous analgesia for the management of pain during uterine artery embolization for leiomyomata. Between April 2004 and July 2004, 15 patients with symptomatic fibroids underwent uterine artery embolization and pain management. Except the three patients for whom the Visual Analogue Scale (VAS) score was not obtained, twelve patients were included in this study. For pain management, epidural PCA (Patient Controlled Analgesia) was used in two patients, intravenous PCA was used in two patients and modified intravenous analgesia injection was used in eight patients. For all the patients, we used the 2.8 Fr coaxial microcatheter and 500-710 {mu} m PVA particles for the embolic materials. The protocol of the modified intravenous analgesia injection was as follow, 1) prior to femoral artery puncture, 30 mg of ketorolac tromethamine (Tarasyn)was injected via an intravenous route. 2) At the time that the one side uterine artery embolization was finished, normal saline mixed 150 mg meperidine (Demerol) was administered through the side port of the intravenous line that was used for hydration. 3) Additional ketorolac tromethamine 30 mg was injected after 6 hour. The VAS score and side effects were then checked. After 12 hours, the VAS score was rechecked. If the VAS score was above 4, this was considered as failure of pain management. The VAS scores, complications and side effects for the modified intravenous analgesia injection were compared with that of IV PCA and epidural PCA. The average VAS score of the modified intravenous analgesia injection, intravenous PCA and epidural PCA was 1.4, 1 and 0, respectively; the number of additional intramuscular injections of analgesia was 0.5, 0.5 and 0, respectively. All the patients who underwent epidural PCA had back pain at the puncture site and 1 patient who underwent modified intravenous analgesia injection experienced mild dyspnea, but they easily recovered with such

  15. Results of Surgical Treatment of Patients with Critical Limb Ischemia and Stenotic Lesions of the Brachiocephalic Arteries

    Directory of Open Access Journals (Sweden)

    Alexei L. Charyshkin

    2017-06-01

    Full Text Available The aim of our study was to evaluate the results of the surgical treatment for patients with critical limb ischemia (CLI and stenotic lesions of the brachiocephalic arteries. Methods and Results: We examined 72 patients (68/87.2% men and 4/7.3% women aged from 46 to 78 years (mean age, 62.2±4.3 years with CLI and stenotic lesions of the brachiocephalic arteries. Conservative treatment was performed in 17(23.6% patients and surgical treatment in 55(76.4%. It has been carried out 73 surgical operations: femoral popliteal bypass (5/6.8%, lumbar sympathectomy (4/5.5%, thrombectomy of occluded aortofemoral graft (2/2.7%, limb amputation (4/5.5%, iliofemoral bypass (4/5.5%, aortofemoral bifurcation bypass (10/13.1%, endovascular surgery (1/1.6%, limb amputation at thigh level - 4(5.5%, thrombectomy of occluded distal arteries (4/5.5%, femoro-femoral cross-over bypass (1/1.6%, resection of popliteal artery aneurysm and prosthesis of the popliteal artery (1/1.6%, semi-closed loop endarterectomy of occluded arteries of the lower limbs (8/10.9%, carotid endarterectomy (23/31.5%, and carotid-subclavian bypass (2/2.7%. After the surgical intervention, we observed the disappearance or reduction of pain, restoration of sensitivity and motor activity, and healing of trophic ulcers in 75% of patients. In the late postoperative period, we detected the progression of limb ischemia in 4(5.5% patients; in connection with that, we performed limb amputation at thigh level. Ischemic stroke with a lethal outcome developed in one patient (1.4%. Conclusion: In patients with multifocal atherosclerosis, multilevel reconstructive surgical interventions must be performed in stages, due to the high operational risk, and risk of complications, secondary amputations and lethality in the postoperative period.

  16. Haemostasis and Safety Measures before Lumbar Puncture in the Haematology Ward

    DEFF Research Database (Denmark)

    Møller, Anders; Bjerrum, Ole Weis; Afshari, Arash

    2015-01-01

    BACKGROUND/AIMS: Thrombocytopenia and the increasing use and variety of antithrombotic drugs is a challenge prior to lumbar puncture. This study examined the Danish haematology practice regarding drug pausation, assessment of haemostasis and whether fundoscopy is a routine safety measure. METHODS...

  17. Liouville theory and uniformization of four-punctured sphere

    OpenAIRE

    Hadasz, Leszek; Jaskolski, Zbigniew

    2006-01-01

    Few years ago Zamolodchikov and Zamolodchikov proposed an expression for the 4-point classical Liouville action in terms of the 3-point actions and the classical conformal block. In this paper we develop a method of calculating the uniformizing map and the uniformizing group from the classical Liouville action on n-punctured sphere and discuss the consequences of Zamolodchikovs conjecture for an explicit construction of the uniformizing map and the uniformizing group for the sphere with four ...

  18. Intraarterial digital subtraction angiography after plastic surgery by thin-needle puncture

    International Nuclear Information System (INIS)

    Langer, M.; Fiegler, W.; Claussen, C.; Koehler, D.; Felix, R.; Hepp, W.

    1984-01-01

    Over the period of a year (1983), 44 intraarterial digital subtraction angiographies (DSA) via direct thin-needle puncture of a vascular bypass or following vascular graft were carried the rough. The only complication that occured: paravasal injection, was clinically insignificant and could be avoided by a change in the puncture-technique. It was possible to carry through the investigation in out-patients. In all cases, diagnostically useful picture material for a possible surgical intervention was obtained. The pictures always were high-grade, independently of the patient's circulation time. Because this is a simple investigation and because of the small risk of complications, it has come to be regularly carried through as a routine in the authors' clinic. According to investigations carried through on the collective of patients of a vascular surgery department, occlusions or anastomotic aneurismus account for most of the angiological disorders. (orig.) [de

  19. Severe tracheobronchial compression in a patient with Turner′s syndrome undergoing repair of a complex aorto-subclavian aneurysm: Anesthesia perspectives

    Directory of Open Access Journals (Sweden)

    Christopher C .C. Hudson

    2014-01-01

    Full Text Available We present a case of severe tracheobronchial compression from a complex aorto-subclavian aneurysm in a patient with Turner′s syndrome undergoing open surgical repair. Significant airway compression is a challenging situation and requires careful preoperative preparation, maintenance of spontaneous breathing when possible, and consideration of having an alternative source of oxygenation and circulation established prior to induction of general anesthesia. Cardiopulmonary monitoring is essential for safe general anesthesia and diagnosis of unexpected intraoperative events.

  20. Effect of puncture through frontal lobe in the treatment of intracranial hematoma

    Directory of Open Access Journals (Sweden)

    DOU Bo-sheng

    2013-12-01

    Full Text Available This study aims to discuss the effect of an easy puncture through frontal lobe in the treatment of deep brain hematoma. The lesions of 37 patients with basal ganglia hemorrhage were accurately positioned by CT scan. Drainage tube was placed in the center of hematoma through frontal lobe and blood was aspirated. Urokinase 30 × 103 U was injected in the hematoma postoperatively to promote the evacuation of hematoma. Postoperative CT scan showed more than 75% hematoma was cleared in all patients after 3-7 d. Two patients died of complications; 2 patients were severely disabled; 3 rebleeding happened. Almost 33 patients had a good recovery. Minimal invasion, convenient operation and exact location were the adventages of this puncture and it does not need complicated device.

  1. Bacterial migration through punctured surgical gloves under real surgical conditions

    Directory of Open Access Journals (Sweden)

    Heidecke Claus-Dieter

    2010-07-01

    Full Text Available Abstract Background The aim of this study was to confirm recent results from a previous study focussing on the development of a method to measure the bacterial translocation through puncture holes in surgical gloves under real surgical conditions. Methods An established method was applied to detect bacterial migration from the operating site through the punctured glove. Biogel™ double-gloving surgical gloves were used during visceral surgeries over a 6-month period. A modified Gaschen-bag method was used to retrieve organisms from the inner glove, and thus-obtained bacteria were compared with micro-organisms detected by an intra-operative swab. Results In 20 consecutive procedures, 194 gloves (98 outer gloves, 96 inner gloves were examined. The rate of micro-perforations of the outer surgical glove was 10% with a median wearing time of 100 minutes (range: 20-175 minutes. Perforations occurred in 81% on the non-dominant hand, with the index finger most frequently (25% punctured. In six cases, bacterial migration could be demonstrated microbiologically. In 5% (5/98 of outer gloves and in 1% (1/96 of the inner gloves, bacterial migration through micro-perforations was observed. For gloves with detected micro-perforations (n = 10 outer layers, the calculated migration was 50% (n = 5. The minimum wearing time was 62 minutes, with a calculated median wearing time of 71 minutes. Conclusions This study confirms previous results that bacterial migration through unnoticed micro-perforations in surgical gloves does occur under real practical surgical conditions. Undetected perforation of surgical gloves occurs frequently. Bacterial migration from the patient through micro-perforations on the hand of surgeons was confirmed, limiting the protective barrier function of gloves if worn over longer periods.

  2. Down syndrome and aberrant right subclavian artery

    NARCIS (Netherlands)

    Roofthooft, Marcus T. R.; van Meer, Hester; Rietman, Wim G.; Ebels, Tjark; Berger, Rolf M. F.

    Down syndrome (DS) may be associated with various organ system disorders. Feeding problems are frequent in children with DS and may be caused by associated defects, including congenital heart defects, gastrointestinal defects, or endocrine disorders. In the absence of these associated conditions,

  3. Central venous catheter placement by an interventional radiology unit: an australian experience

    International Nuclear Information System (INIS)

    Lee, M. K. S.; Mossop, P. J.; Vrazas, J. I.

    2007-01-01

    The aim of this retrospective study was to analyse the outcomes of central venous catheter (CVC) placement carried out by an interventional radiology unit. A review of our hospital records identified 331 consecutive patients who underwent insertion of a tunnelled or non-tunnelled CVC between January 2000 and December 2004. Key outcome measures included the technical success rate of CVC insertion and the percentage of immediate ( 30 days) complications. A total of 462 CVCs were placed under radiological guidance, with an overall success rate of 98.9%. Immediate complications included one pneumothorax, which was diagnosed 7 days after subclavian CVC insertion, and eight episodes of significant haematoma or bleeding within 24 h of CVC insertion. No cases were complicated by arterial puncture or air embolus. Catheter-related sepsis occurred in 2% of non-tunnelled CVC and 8.9% of tunnelled CVC. The overall incidence of catheter-related sepsis was 0.17 per 100 catheter days. As the demand for chemotherapy and haemodialysis grows with our ageing population, interventional radiology suites are well placed to provide a safe and reliable service for the placement of central venous access devices

  4. The Role of Multi-slice Spiral CT Angiography in Patient Management After Endovascular Therapy

    International Nuclear Information System (INIS)

    Peloschek, P.; Sailer, J.; Loewe, C.; Schillinger, M.; Lammer, J.

    2006-01-01

    Objectives. To bring out the role of multi-slice spiral CT angiography (MS-CTA) in patient management after endovascular therapy of subclavian artery stenosis. Methods. Twenty-one consecutive patients with clinically suspected restenosis after endovascular treatment of subclavian artery stenosis or occlusion were included in the study. Eleven patients had been treated with percutaneous transluminal angioplasty (PTA) alone and 10 with PTA and stenting. The mean follow-up period after PTA or stenting was 57 (±27 SD) months. CTA was performed using a bolus-triggered high-resolution protocol with biphasic intravenous contrast medium injection. Axial images and curved planar reformations (CPRs) were rated by three readers with regard to patency of supra-aortic vessels. Imaging findings were correlated with a standardized clinical assessment. Results. All examinations were of diagnostic quality. Of 21 referred patients, 7 had significant reobstruction of the treated subclavian artery. Six of the 7 patients with significant restenosis on CTA were treated conservatively (antiplatelet agents), despite 2 of them being symptomatic on the standardized clinical assessment, which showed a sensitivity and specificity of 86% in predicting stenosis. One patient was treated with PTA and stent deployment because of strong subjective suffering. Conclusion. MS-CTA is useful for exclusion or quantification of clinically suspected restenosis in carefully selected patients after endovascular therapy where ultrasound is inconclusive and/or contrast-enhanced magnetic resonance angiography is contraindicated

  5. Bilateral Pneumothoraces Following Central Venous Cannulation

    Directory of Open Access Journals (Sweden)

    F. Pazos

    2009-01-01

    Full Text Available We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax.

  6. Bilateral Pneumothoraces Following Central Venous Cannulation

    Science.gov (United States)

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax. PMID:19901997

  7. Phrenic paralysis during cardiac electronic device implantation: incidence, causes and clinical course.

    Science.gov (United States)

    López-Gil, María; Fontenla, Adolfo; Juliá, Justo; Parra, Juan José; Arribas, Fernando

    2016-10-01

    Phrenic paralysis is a known complication of central venous catheterization, but it is not listed as a complication related to cardiac implantable electronic device (CIED) implants. The aim of this study is to describe the incidence, causes, clinical picture, and management of phrenic paralysis occurring in this scenario. We retrospectively analysed data from our CIED implantation database and identified those patients who suffered phrenic paralysis during the implantation procedure. Four of 891 patients (subclavian puncture in 626) developed phrenic paralysis during pacemaker or defibrillator implant procedures. Severe respiratory failure needing ventilatory support occurred in two, being the phrenic paralysis transient in all of the cases. Transient phrenic paralysis may occur during CIED implantation probably related to the infiltration of local anaesthesia in the subclavian area. Mechanism, prevention, and management are discussed. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  8. Significant Improvement of Puncture Accuracy and Fluoroscopy Reduction in Percutaneous Transforaminal Endoscopic Discectomy With Novel Lumbar Location System: Preliminary Report of Prospective Hello Study.

    Science.gov (United States)

    Fan, Guoxin; Guan, Xiaofei; Zhang, Hailong; Wu, Xinbo; Gu, Xin; Gu, Guangfei; Fan, Yunshan; He, Shisheng

    2015-12-01

    Prospective nonrandomized control study.The study aimed to investigate the implication of the HE's Lumbar LOcation (HELLO) system in improving the puncture accuracy and reducing fluoroscopy in percutaneous transforaminal endoscopic discectomy (PTED).Percutaneous transforaminal endoscopic discectomy is one of the most popular minimally invasive spine surgeries that heavily depend on repeated fluoroscopy. Increased fluoroscopy will induce higher radiation exposure to surgeons and patients. Accurate puncture in PTED can be achieved by accurate preoperative location and definite trajectory.The HELLO system mainly consists of self-made surface locator and puncture-assisted device. The surface locator was used to identify the exact puncture target and the puncture-assisted device was used to optimize the puncture trajectory. Patients who had single L4/5 or L5/S1 lumbar intervertebral disc herniation and underwent PTED were included the study. Patients receiving the HELLO system were assigned in Group A, and those taking conventional method were assigned in Group B. Study primary endpoint was puncture times and fluoroscopic times, and the secondary endpoint was location time and operation time.A total of 62 patients who received PTED were included in this study. The average age was 45.35 ± 8.70 years in Group A and 46.61 ± 7.84 years in Group B (P = 0.552). There were no significant differences in gender, body mass index, conservative time, and surgical segment between the 2 groups (P > 0.05). The puncture times were 1.19 ± 0.48 in Group A and 6.03 ± 1.87 in Group B (P HELLO system is accurate preoperative location and definite trajectory. This preliminary report indicated that the HELLO system significantly improves the puncture accuracy of PTED and reduces the fluoroscopic times, preoperative location time, as well as operation time. (ChiCTR-ICR-15006730).

  9. Development of stroke-induced quadriplegia after endovascular repair of blunt aortic injury pseudoaneurysm.

    Science.gov (United States)

    Amoudi, Abdullah S; Merdad, Anas A; Makhdoom, Ahmed Q; Jamjoom, Reda A

    2015-01-01

    Endovascular repair of blunt aortic injury is now a first-line approach in management. This can warrant coverage of the left subclavian artery (LSA), which could lead to posterior strokes. In this case report, we present a severe complication of endovascular repair of a traumatic aortic aneurysm. A 53-year-old man presented with blunt aortic injury, endovascular repair was carried out where the left subclavian artery was covered. The intervention had a 100% technical success. Twelve hours later, he was discovered to have quadriplegia, a CT scan showed a large left cerebellar infarction extending to the medulla oblongata and proximal spinal cord. Strokes complicate 3% of thoracic endovascular aortic repairs, 80% of those strokes occur in patients who had their LSA`s covered. Most patients however, tolerate the coverage. Although our patient had a dominant right vertebral artery, and lacked risks for these strokes, he developed an extensive stroke that left him quadriplegic.

  10. Marked lateral deviation of the phrenic nerve due to variant origin and course of the thyrocervical trunk: a cadaveric study.

    Science.gov (United States)

    Ogami, Keiko; Saiki, K; Okamoto, K; Wakebe, T; Manabe, Y; Imamura, T; Tsurumoto, T

    2016-05-01

    Phrenic nerve impairment can often lead to serious respiratory disorders under various pathological conditions. During routine dissection of an 88-year-old Japanese male cadaver, a victim of heart failure, we recognized an extremely rare variation of the right thyrocervical trunk arising from the subclavian artery laterally to the anterior scalene muscle. In addition to that, the ipsilateral phrenic nerve was drawn and displaced remarkably laterad by this vessel. We examined all of the branches arising from subclavian arteries, phrenic nerves and diaphragm muscles. The embryological background of this arterial variation is considered. The marked displacement with prolonged strain had a potential to cause phrenic nerve impairment with an atrophic change of the diaphragm muscle. Recently many image diagnostic technologies have been developed and are often used. However, it is still possible that rare variations like this case may be overlooked and can only be recognized by intimate regional examination while keeping these rare variations in mind.

  11. Embolization of Life-Threatening Arterial Rupture in Patients with Vascular Ehlers–Danlos Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Takuya, E-mail: okabone@gmail.com [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Frank, Michael, E-mail: michael.frank@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Rare Vascular Diseases Reference Center (France); Pellerin, Olivier, E-mail: olivier@pellerin.as; Primio, Massimiliano Di, E-mail: massimiliano.di.primio@gmail.com; Angelopoulos, Georgios, E-mail: giorginos78@msn.com [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Boughenou, Marie-Fazia, E-mail: marie-fazia.boughenou@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Anesthesia and Surgical Intensive Care Unit (France); Pagny, Jean-Yves, E-mail: jean-yves.pagny@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Messas, Emmanuel, E-mail: emmanuel.messas@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Rare Vascular Diseases Reference Center (France); Sapoval, Marc, E-mail: marc.sapoval2@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France)

    2013-05-09

    PurposeTo evaluate the safety and efficacy of transarterial embolization of life-threatening arterial rupture in patients with vascular Ehlers–Danlos syndrome (vEDS) in a single tertiary referral center.MethodsWe retrospectively analyzed transarterial embolization for vEDS performed at our institution from 2000 to 2012. The indication of embolization was spontaneous arterial rupture or pseudoaneurysm with acute bleeding. All interventions used a percutaneous approach through a 5F or less introducer sheath. Embolic agents were microcoils and glue in 3 procedures, glue alone in 2, and microcoils alone in 2.ResultsFive consecutive vEDS patients were treated by 7 embolization procedures (4 women, mean age 29.8 years). All procedures were successfully performed. Two patients required a second procedure for newly arterial lesions at a different site from the first procedure. Four of the five patients were still alive after a mean follow-up of 19.4 (range 1–74.7) months. One patient died of multiple organ failure 2 days after procedure. Minor procedural complications were observed in 3 procedures (43 %), all directly managed during the same session. Remote arterial lesions occurred after 3 procedures (43 %); one underwent a second embolization, and the other 2 were observed conservatively. Puncture site complication was observed in only one procedure (14 %).ConclusionEmbolization for vEDS is a safe and effective method to manage life-threatening arterial rupture.

  12. Embolization of Life-Threatening Arterial Rupture in Patients with Vascular Ehlers–Danlos Syndrome

    International Nuclear Information System (INIS)

    Okada, Takuya; Frank, Michael; Pellerin, Olivier; Primio, Massimiliano Di; Angelopoulos, Georgios; Boughenou, Marie-Fazia; Pagny, Jean-Yves; Messas, Emmanuel; Sapoval, Marc

    2014-01-01

    PurposeTo evaluate the safety and efficacy of transarterial embolization of life-threatening arterial rupture in patients with vascular Ehlers–Danlos syndrome (vEDS) in a single tertiary referral center.MethodsWe retrospectively analyzed transarterial embolization for vEDS performed at our institution from 2000 to 2012. The indication of embolization was spontaneous arterial rupture or pseudoaneurysm with acute bleeding. All interventions used a percutaneous approach through a 5F or less introducer sheath. Embolic agents were microcoils and glue in 3 procedures, glue alone in 2, and microcoils alone in 2.ResultsFive consecutive vEDS patients were treated by 7 embolization procedures (4 women, mean age 29.8 years). All procedures were successfully performed. Two patients required a second procedure for newly arterial lesions at a different site from the first procedure. Four of the five patients were still alive after a mean follow-up of 19.4 (range 1–74.7) months. One patient died of multiple organ failure 2 days after procedure. Minor procedural complications were observed in 3 procedures (43 %), all directly managed during the same session. Remote arterial lesions occurred after 3 procedures (43 %); one underwent a second embolization, and the other 2 were observed conservatively. Puncture site complication was observed in only one procedure (14 %).ConclusionEmbolization for vEDS is a safe and effective method to manage life-threatening arterial rupture

  13. Thrombolysis for acute lower limb arterial embolism in patients with recent cerebral embolism

    International Nuclear Information System (INIS)

    Si Tongguo; Guo Zhi

    2008-01-01

    Objective: To assess the feasibility and efficacy of catheter-directed thrombolysis with recombinant tissue plasminogen activator (rt-PA)for acute limb embolism in patients with recent cerebral embolism. Methods: Eight patients with atrial fibrillation history happened to suffer acute limb embolism after recent cerebral embolism. The affected arteries included 2 left common iliac arteries, 4 femoral arteries (3 left, 1 right), 2 right popliteal arteries. Catheter-directed thrombolysis with rt-PA was applied with bolus administration plus continuous perfusion. Percutaneous transluminal angioplasty with balloon dilatation was applied in 3 patients, and one stent placement in one patient. Results: The mean duration of continuous perfusion was 3.6 hours and the mean dose of rt-PA administered was 23.6 mg (range, 20-28 mg)with complete recanalization rate of 100%. Clinical complete relief rate was 7/8 with one patient suffering from rest pain due to distal occlusion of anterior/posterior tibial artery. The complications included hematoma at puncture site (6/8), bleeding around the vascular sheath (2/8)and hematuria (1/8). NO intracerebral hemorrhage was found on CT scans after the thrombolysis. During follow up of 3-6 months, no recurrent embolism or thrombosis occurred in the limbs except one patient with recurrent cerebral embolism and died. Conclusions: Catheter-directed thrombolysis with rt-PA is probably to be a safe and effective method for acute limb embolism in patients with recent cerebral embolism and atrial fibrillation history. (authors)

  14. Combined Directional Atherectomy and Drug-Eluting Balloon Angioplasty for Isolated Popliteal Artery Lesions in Patients With Peripheral Artery Disease.

    Science.gov (United States)

    Stavroulakis, Konstantinos; Bisdas, Theodosios; Torsello, Giovanni; Stachmann, Arne; Schwindt, Arne

    2015-12-01

    To evaluate the midterm results of combined directional atherectomy (DA) and drug-eluting balloon (DEB) angioplasty for atherosclerotic lesions of the popliteal artery. In a single-arm, prospective study, 21 patients (mean age 63±16 years; 16 men) with isolated popliteal artery lesions were enrolled and underwent treatment with combined DA and DEB angioplasty under filter protection between October 2009 and February 2014. The majority (18, 86%) presented with lifestyle-limiting intermittent claudication and 3 with critical limb ischemia. Fifteen (71%) target sites were de novo lesions; 4 were occlusions. The main outcome was primary patency; secondary outcomes were technical success, secondary patency, and early and midterm morbidity and mortality. The TurboHawk atherectomy device was used in 15 (71%) patients and the SilverHawk peripheral plaque excision system in the remaining 6 patients. The In.Pact Admiral/Pacific DEB was used in the majority of cases (15, 71%). The technical success rate was 90% (n=19). One flow-limiting dissection was treated with bailout stenting. Complications included a perforation of the popliteal artery and 2 puncture site hematomas; there was no distal embolic event. The mean follow-up was 18±12 months. Two restenoses were retreated successfully. Kaplan-Meier estimates of primary patency at 12 and 18 months were 95% and 90%, respectively; the secondary patency was 100%. One (5%) patient died in follow-up. None of the patients had an amputation. In this prospective single-arm study, the combined therapy of DA and DEB angioplasty for popliteal artery lesions showed promising midterm performance. The combination of DA and DEB may, in highly selected patients, overcome the challenges presented by the mobility of the knee joint. © The Author(s) 2015.

  15. Sudden headache, lumbar puncture, and the diagnosis of subarachnoid hemorrhage in patients with a normal computed tomography scans.

    Science.gov (United States)

    Valle Alonso, Joaquín; Fonseca Del Pozo, Francisco Javier; Vaquero Álvarez, Manuel; De la Fuente Carillo, Juan José; Llamas, José Carlos; Hernández Montes, Yelda

    2018-02-01

    To assess the usefulness of computed tomography (CT) to identify subarachnoid bleeding in patients with neurologic deficits seeking emergency care for sudden headache within 6 hours of onset of symptoms. Retrospective observational study of patients presenting with sudden nontraumatic headache peaking during the previous hour in the absence of neurologic deficits. We ordered CT scans for all patients, and if the scan was normal we performed a lumbar puncture. All patients were then followed for 6 months. Eighty-five patients were included. Subarachnoid bleeding was identified in 10 (10.2%) patients by CT. Seventy- four lumbar punctures were performed in patients with negative CTs; the lumbar puncture was positive in 1 patient and inconclusive in 2 patients. In all 3 patients, bleeding was ruled out with later images; thus, no cases of subarachnoid hemorrhage were confirmed in the 74 patients who underwent lumbar puncture. Nor were any cases found in any of these patients during follow-up. A CT scan taken within 6 hours of onset of sudden headache is sufficient for confirming or ruling out subarachnoid bleeding in patients with sudden headache who have no neurologic deficits.

  16. Variability of the vertebral artery origin and transverse foramen entrance level - CT angiographic study.

    Science.gov (United States)

    Vujmilović, Siniša; Spasojević, Goran; Vujnović, Saša; Malobabić, Slobodan; Vujković, Zoran

    2018-04-13

    Vertebral artery (VA), the main element of the posterior brain circulation, has many anatomical variations which generally were widely investigated. However, available data vary in wide ranges, reflecting very different sample sizes, lack of data about left-right or sex differences, and about possible ethnic, regionally specific or genetic differences. Certain new findings suggest possible involvement of some environmental factors in VA variations. Accurate anatomical data about VA variations in different regions of the world, including Balkans countries, are still lacking. Therefore we investigated morphological variability of VA origin and its entrance level into cervical transverse foramina in population of Republika Srpska (Bosnia and Herzegovina), including data about the sex and side. Anatomy of VA was investigated in 112 persons (224 arteries) of both sexes (58 males, 54 females; age 19 - 83 years), using 64-slice CT scanner. Origin of VA from subclavian artery (SCA) we found in 95.08% of arteries (52 males, 49 females). Only in one male (0.45 %) left VA and left SCA had an specific origin from aortic arch (AA), which we named as an "common area of origin". All other observed variations in origin were only of left VA, originating from AA in 4.47 % (5 males, 5 females). Left VA Most often (usual) entrance level into transverse foramen we found at C6 (87.5%), followed by C5 (8.93 %), C4 (3.12 %), and in one case at level C7 (0.45 %). Entry levels at C5 both, on right and on the left side, were 3 times more frequent in males than in females. Wide ranges of differences between the data we obtained on a sample in Republika Srpska (Bosnia and Herzegovina) and the data from many other studies require further and wider investigations.

  17. Analysis of the population at high risk of stroke detected with carotid artery ultrasonography in Tianjin urban communities

    Directory of Open Access Journals (Sweden)

    Wei YUE

    2015-04-01

    Full Text Available Objective To investigate the features of carotid atherosclerosis in a population at high risk of stroke in urban communities of Tianjin, so as to provide inspiration for carotid ultrasonography to play a greater role in the prevention and control of stroke.  Methods A total of 956 residents at high risk of stroke were selected from 4 urban communities in Tianjin using cluster random sampling method. Doppler ultrasound screening was performed in bilateral common carotid artery (CCA, internal carotid artery (ICA, external carotid artery (ECA, vertebral artery (VA, subclavian artery (SCA and innominate artery of the population. The intima-media thickness (IMT, atherosclerotic plaque formation and its location and size, vascular stenosis or occlusion, and flow spectrum were detected. The results and features of carotid ultrasound screening were analyzed and compared among different gender and age groups.  Results 1 The detection rate of carotid atherosclerosis was 71.55% (684/956, and the detection rate in males was significantly higher than that in females (79.08% vs 65.87%; χ2 = 20.067, P = 0.000. 2 Among the population with carotid atherosclerosis, the most common manifestation was the formation of atherosclerotic plaques (81.58%, 558/684, secondly intima-media thickening (13.01%, 89/684, followed by moderate to severe stenosis or occlusion (5.41%, 37/684. The proportion of intima-media thickening in males was lower than that in females (7.08% vs 18.38%; χ2 = 19.269, P = 0.000. The proportion of carotid atherosclerotic plaque formation in males was higher than that in females (86.46% vs 77.16%; χ2 = 9.824, P = 0.002. The median rating of carotid atherosclerosis was 1.79, with males higher than females [1.98 (0.70, 3.26 vs 1.52 (0.20, 2.84; Z = 2.304, P = 0.042]. The site of plaque formation was most commonly located in carotid bulb (36.61%, secondly SCA (22.18%. Of the type of carotid stenosis, ICA stenosis was detected in 30 cases, VA

  18. Midterm results of endovascular stent graft treatment for descending aortic aneurysms including high-risk patients

    Directory of Open Access Journals (Sweden)

    Gussmann, Andreas

    2006-04-01

    Full Text Available Methods: 21 patients (17 men, 4 women; mean age 66.1 years, range 29-90 years with 15 true aneurysms, and 6 type B-dissections were treated by implantation of a TalentTM Endoluminal Stentgraft System from February 2000 to July 2003. In 3 cases it was necessary to overstent the left subclavian artery, in 1 case to overstent the left common carotid. Results: 2 patients (9.5% died during the first 30 days (1 myocardial infarction, 1 pneumonia. Two patients (9.5% suffered from cerebral ischemia and needed revascularisation. No paraplegia, no stroke occurred. One endoleak required additional stenting. No patient needed conversion. Follow-up, average 25.4 months (range 0-39, was 100% complete. During this another two patients died of myocardial infarction i.e. 9.5% (the above mentioned endoleak, but no late migration were detected in the remaining patients. In all cases the graft lumen stayed patent. Conclusions: Treatment of descending thoracic aortic aneurysm with an endovascular approach has acceptable mortality and morbidity-rates even in high risk patients. Procedural overstenting of the subclavian artery requires subclavian revascularisation in a minority of cases.

  19. [Supra-aortic trunks occlusive disease: three different treatment approaches].

    Science.gov (United States)

    Dias, P; Almeida, P; Sampaio, S; Silva, A; Leite-Moreira, A; Pinho, P; Roncon de Albuquerque, R

    2010-01-01

    Unlike carotid bifurcation atherosclerotic stenosis, supra-aortic trunks (SAT) occlusive disease is rare and its revascularization uncommon, accouting for less than 10% of the operations performed on the extracranial brain-irrigating arteries. There are three different treatment approaches: transthoracic, extra-anatomic cervical and endovascular. Endovascular repair is gaining popularity as first-line therapy for proximal lesions with favorable anatomy because of its low morbidity and rare mortality. Extra-anatomic bypass is a safe and durable reconstruction and should be considered in patients with single vessel disease, with cardiopulmonary high-risk or with limited life expectancy. If cardiac surgery is needed, central transthoracic reconstruction is preferable, and the two procedures should be combined. The long-term patency of bypasses with aortic origin, specially when multiple vessels are involved, is superior to other repair techniques. We present three clinical cases that illustrate each of these therapeutic strategies: central brachiocephalic revascularization and synchronous cardiac surgery in a patient with complex SAT atherosclerosis disease; subclavian-carotid transposition for disabling upper limb claudication; and subclavian artery stenting for subclavian-steal syndrome. Surgical approach selection should be based on the individual patient's anatomy and operative risk.

  20. ANOMALOUS PREVERTEBRAL COURSE OF THE LEFT VERTEBRAL ARTERY. Recorrido prevertebral anómalo de la arteria vertebral izquierda

    Directory of Open Access Journals (Sweden)

    Prakash B Billakanti

    2016-03-01

    Full Text Available La arteria vertebral es una de las arterias que irriga el cerebro. El conocimiento de la anatomía normal y las variantes de la arteria vertebral adquiere importancia en la práctica clínica y la radiología vascular. El origen anómalo de la arteria vertebral del arco de la aorta o cualquiera de las arterias del cuello ha sido reportado por muchos autores. En este informe se presenta una variación del curso prevertebral de la arteria vertebral izquierda. La arteria vertebral tenía su origen habitual en la arteria subclavia con un largo curso prevertebral y entraba en el foramen transversarium de la vértebra CII. El origen y recorrido de la arteria vertebral en el lado derecho fue normal. Clínicamente es importante conocer el origen y curso del segmento prevertebral de la arteria vertebral y las posibles variaciones. El presente informe debería ser de interés para el médico vascular con respecto a las variaciones en el cuello y región torácica, y puede dar idea para dilucidar el mecanismo de desarrollo de la angiogénesis. Vertebral artery is one of the arteries supplying the brain. Knowledge of the normal and variant anatomy of the vertebral artery assumes importance in clinical practice and vascular radiology. Anomalous origins of the vertebral artery from the arch of the aorta or any one of the arteries of the neck have been reported by several authors. In this report a variation of the prevertebral course of the left vertebral artery is being presented. The Vertebral artery had usual origin from the subclavian artery and had a longer prevertebral course to enter the foramen transversarium of the CII vertebra. The origin and course of the vertebral artery on the right side was normal. It is clinically important to know the origin and course of the prevertebral segment of the vertebral artery and possible variations. The present report should be of interest for clinicians with regard to vascular variations in the neck and thoracic

  1. Oviposition punctures in cucurbit fruits and their economic damage caused by the sterile female melon fly, Bactrocera cucurbitae Coquillett

    International Nuclear Information System (INIS)

    Miyatake, T.; Irabu, T.; Higa, R.

    1993-01-01

    Oviposition punctures caused by sterile females of the tephritid Bactrocera cucurbitae in cucurbit fruits were examined and economic damage was evaluated in Okinawa, Ryukyu Archipelago, Japan. Cage experiments in the field confirmed that sterile females make punctures (sterile stings) on fruits. The features of sterile stings differed depending on fruit species and were classified into 5 types

  2. Headache in the parturient: Pathophysiology and management of post-dural puncture headache

    Directory of Open Access Journals (Sweden)

    Gita Nath

    2011-01-01

    Full Text Available Headache in the postpartum period is common and multifactorial in origin. Apart from primary causes such as tension headaches and migraine, secondary headaches such as post-dural puncture headache (PDPH are increasingly common because of increasing use of regional anaesthesia and analgesia during childbirth. Preventive measures for PDPH include the use of smaller gauge pencil-point needles for spinal blocks; epidural needles of 18 G or less; using saline rather than air for epidural space identification and the use of ultrasound guidance, especially for difficult cases such as morbid obesity and spinal deformities. In case of accidental dural puncture (ADP, the choice is between inserting the catheter in an adjacent space or intrathecal catheterization. Current evidence seems to be in favour of inserting the epidural catheter into the subarachnoid space and using the intrathecal catheter for analgesia/anaesthesia after prominently labelling it as intrathecal, to prevent misuse. It should be removed after at least 24 hours and a 10 ml bolus of saline injected before removal of catheter may be helpful. Either way, having written protocols for the management of accidental dural puncture helps to reduce the incidence of PDPH. PDPH can be disabling in severity and can mar the whole experience of childbirth. In addition, severe untreated PDPH can cause complications such as nerve palsies, subdural hematoma and cerebral venous thrombosis. Conservative methods of treatment should be tried first such as adequate hydration, paracetamol, caffeine, sumatriptan or ACTH/hydrocortisone. Epidural blood patching is the most effective treatment for PDPH. It is more effective if done 24-48 hours after dural puncture. It is an invasive procedure with its own complications as well as a failure rate of up to 30%, so that a second or even third patch may be necessary. Both these facts should be intimated to the patient beforehand. Meticulous follow-up and evaluation

  3. Novel experience of laser-assisted 'inside-out' central venous access in a patient with bilateral subclavian vein occlusion requiring pacemaker implantation.

    Science.gov (United States)

    Aye, Thandar; Phan, Thanh Trung; Muir, Douglas Findlay; Linker, Nicholas John; Hartley, Richard; Turley, Andrew John

    2017-10-01

    This new laser facilitated 'inside-out' technique was used for transvenous pacemaker insertion in a pacemaker-dependent patient with bilateral subclavian occlusion and a failed epicardial system who is not suitable for a transfemoral approach. Procedure was undertaken under general anaesthesia with venous access obtained from right femoral vein and left axillary vein. 7F multipurpose catheter was used to enter proximal edge of the occluded segment of subclavian vein via femoral approach, which then supported stiff angioplasty wires and microcatheters to tunnel into the body of occlusion. When encountered with impenetrable resistance, 1.4 mm Excimer laser helped delivery of a Pilot 200 wire, which then progressed towards the distal edge of occlusion. Serial balloon dilatations allowed wire tracked into subintimal plane, advanced towards left clavicle using knuckle wire technique, which was then externalized with blunt dissection from infraclavicular pocket area. It was later changed to Amplatz superstiff wire exiting from both ends to form a rail, which ultimately allowed passage of pacing leads after serial balloon dilatation from clavicular end. Our hybrid 'inside-out' technique permitted transvenous pacemaker insertion without complication and this is, to our knowledge, the first case using laser in this context. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  4. Cervical myelography via C1/C2 lateral puncture

    International Nuclear Information System (INIS)

    Grange, B.

    1981-01-01

    The use of the water soluble, tri-iodinated contrast medium, metrizamide, in cervical myelography via C1/C2 lateral puncture is described. Details of the tomographic apparatus and the technique employed are given. The advantages of water soluble myelography using metrizamide are overwhelming due to its miscibility with CSF, improved anatomical demonstration, radiographic visualisation and diagnostic accuracy and advantageous pharmacological properties with reduced toxicity. This technique provided successful diagnoses in a series of 104 patients. (U.K.)

  5. Direct right ventricular puncture for hemodynamic evaluation of a mechanical tricuspid valve prosthesis: a new indication for an old procedure.

    Science.gov (United States)

    Gibson, M A; Carell, E S

    1997-11-01

    The advent of transvenous right heart catheterization has relegated direct transthoracic right ventricular puncture largely to the role of "interesting historical footnote." However, in the case of a right ventricle that is "protected" by a mechanical tricuspid valve prosthesis, direct right ventricular puncture represents a reasonable alternative for obtaining accurate hemodynamic information.

  6. [Endovascular radiofrequency denervation of renal arteries as an innovation method of treatment of refractory arterial hypertension. First experience in Russia].

    Science.gov (United States)

    Danilov, N M; Matchin, Iu G; Chazova, I E

    2012-01-01

    Excessive activation of the sympathetic nervous system forms the basis of pathogenesis of essential arterial hypertension (AH). The present work was aimed at evaluating efficacy and safety of endovascular radiofrequency denervation of renal arteries in patients with AH refractory AH based on the initial first experience in with using this methodology in the Russian Federation. The interventions were carried out on December 14-15th, 2011 in the first five patients presenting with AH refractory to antihypertensive therapy consisting of three and more drugs in therapeutic doses, one of which was a diuretic. The selection criteria were systolic arterial pressure (SAP) ≥160 mm Hg or ≥150 mm Hg in the presence of type 2 diabetes mellitus. The obligatory conditions for selection were the preserved renal function [glomerular filtration rate (GFR) ≥45 ml/min] and the absence of the secondary form of AH. The procedure of denervation was performed in the conditions of roentgen-operating room using special Medtronic Ardian Simplicity Catheter System™. In all cases we managed to perform bilateral denervation of renal arteries with the radiofrequency effect in not less than 4 zones of each of vessels. Efficacy of each of the effect was registered with due regard for reaching certain temperature and values of impedance. The interventions were not accompanied by the development of any complications either in the area of manipulations or the site of puncture. Neither were there any complications from the side of the cardiovascular or excretory systems of the body. Diurnal monitoring of AP (DMAP) registered a significant decrease in SAP averagely from 174±12 to 145±10 mm Hg three days after the intervention. A persistent antihypertensive effect was confirmed by the DMAP findings one month after denervation - the SAP level averagely amounted to 131±6 mm Hg. Endovascular radiofrequency denervation of renal arteries is a safe and efficient method of treatment of AH resistant

  7. Reinvestigation of moving punctured black holes with a new code

    International Nuclear Information System (INIS)

    Cao Zhoujian; Yo Hweijang; Yu Juiping

    2008-01-01

    We report on our code, in which the moving puncture method is applied and an adaptive/fixed mesh refinement is implemented, and on its preliminary performance on black hole simulations. Based on the Baumgarte-Sharpiro-Shibata-Nakamura (BSSN) formulation, up-to-date gauge conditions and the modifications of the formulation are also implemented and tested. In this work, we present our primary results about the simulation of a single static black hole, of a moving single black hole, and of the head-on collision of a binary black hole system. For the static punctured black hole simulations, different modifications of the BSSN formulation are applied. It is demonstrated that both the currently used sets of modifications lead to a stable evolution. For cases of a moving punctured black hole with or without spin, we search for viable gauge conditions and study the effect of spin on the black hole evolution. Our results confirm previous results obtained by other research groups. In addition, we find a new gauge condition, which has not yet been adopted by any other researchers, which can also give stable and accurate black hole evolution calculations. We examine the performance of the code for the head-on collision of a binary black hole system, and the agreement of the gravitational waveform it produces with that obtained in other works. In order to understand qualitatively the influence of matter on the binary black hole collisions, we also investigate the same head-on collision scenarios but perturbed by a scalar field. The numerical simulations performed with this code not only give stable and accurate results that are consistent with the works by other numerical relativity groups, but also lead to the discovery of a new viable gauge condition, as well as clarify some ambiguities in the modification of the BSSN formulation. These results demonstrate that this code is reliable and ready to be used in the study of more realistic astrophysical scenarios and of numerical

  8. Acute limb ischemia caused by incorrect deployment of a clip-based arterial closure device

    Directory of Open Access Journals (Sweden)

    Łukasz Dzieciuchowicz

    2016-04-01

    Full Text Available Failure of a vascular closure device most commonly results in a hemorrhage or pseudoaneurysm formation. In this paper a rare case of severe acute limb ischemia following incorrect deployment of a clip-based closure device (Starclose SE, Abbott Vascular in a 31-year-old woman is presented. Symptoms of acute limb ischemia occurred at the start of the ambulation, 6 h after completion of the procedure. Because of the severity of ischemia the patient was treated surgically, and limb perfusion was successfully restored. An attempt of closure of an inadvertently punctured narrow superficial femoral artery was identified as the cause of this complication.

  9. Bedside prediction of right subclavian venous catheter insertion length

    Directory of Open Access Journals (Sweden)

    Yoon Ji Choi

    2014-12-01

    Full Text Available Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC, via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively. Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89. The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm = -0.037 + 0.036 × Height (cm + 0.903 × I-T-IC (cm (adjusted r2 =0.64. Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation.

  10. Cerebral venous and sinus thrombosis with cerebrospinal fluid circulation block after the first methotrexate administration by lumbar puncture

    International Nuclear Information System (INIS)

    Bienfait, H.P.; Gijtenbeek, J.M.M.; Bent, M.J. van; Bruin, H.G. de; Voogt, P.J.; Pillay, M.

    2002-01-01

    We report a patient treated for small lymphocytic lymphoma/leukemia with cerebral venous and sinus thrombosis (CVST) after lumbar puncture with intrathecal administration of methotrexate (MTX). He also developed a cerebrospinal fluid flow block. This is the first report of an association between lumbar puncture and intrathecally administered MTX and the development of CVST. Intrathecal treatment in this patient was discontinued and he was successfully treated with high-dose low-molecular-weight heparin subcutaneously. (orig.)

  11. Experience and nursing needs of school-age children undergoing lumbar puncture during the treatment of acute lymphoblastic leukaemia: a descriptive and qualitative study.

    Science.gov (United States)

    Xie, Anwei; Shan, Yuying; Niu, Mei E; Chen, Yi; Wang, Xiya

    2017-11-01

    To describe experiences and nursing needs of school-age Chinese children undergoing lumbar puncture for the treatment of acute lymphoblastic leukaemia. Lumbar puncture is an invasive procedure, causing psychological changes and physical discomfort in patients. In a previous study, it was proved that distraction intervention, such as music therapy, relieves pain and anxiety. There is limited evidence regarding the experience and needs of school-age children during lumbar puncture after being diagnosed with acute lymphoblastic leukaemia. To minimise their anxiety and pain during the procedure, it is important to collect information directly from these children. A descriptive qualitative research. Twenty-one school-age children with acute lymphoblastic leukaemia participated in semi-structured interviews at a Children's Hospital in China. Data were collected by an experienced and trained interviewer. Qualitative content analysis was chosen to describe experiences of children undergoing lumbar puncture. While undergoing lumbar puncture for the treatment of acute lymphoblastic leukaemia, school-age Chinese children experienced complex psychological feelings (fear, tension, helplessness, sadness and anxiety). They also experienced physical discomfort. They had multipolar needs, such as information, communication, respect, self-actualisation, environment and equipment. This study identified important areas that must be closely monitored by healthcare staff, performing lumbar puncture on acute lymphoblastic leukaemia children. Thus, a successful and smooth procedure can be performed on these patients, and their quality of life can be improved. The experiences described in this study contribute to a better understanding of the needs of acute lymphoblastic leukaemia children undergoing lumbar puncture. They also provide valuable information to professional medical care staff that develops future nursing assessments. © 2016 John Wiley & Sons Ltd.

  12. Experimental impact and puncture evaluation of the prototype quarter scale TRU transporter package

    International Nuclear Information System (INIS)

    Meyer, R.J.; Plonski, B.A.; Vigil, M.G.; Joseph, B.J.

    1983-01-01

    The impact tests consist of the TRUPACT model free-falling 9 meters onto a flat, horizontal, unyielding surface as specified in 10CFR71. The model was dropped at five different orientations including: (1) flat on the door end; (2) flat on the side; (3) center of gravity over impact corner; (4) flat on edge; and (5) corner impact edge slapdown. The model instrumentation for these tests included: (1) sixty strain gages located throughout the model structure used to obtain impact stresses; (2) three displacement transducers used to measure relative motion between the inner door and inner cavity frame structure (seal integrity); and (3) two triaxial accelerometers used to estimate the impact forces on the inner and outer frame structures. The drop/puncture tests consisted of the TRUPACT-I model free-falling one meter onto a 38-millimeter (1.5-inch) diameter mild steel punch 0.9 meters (36 inches) long. The punch was welded to an unyielding surface. Model drop/puncture orientations included: (1) flat on the model sides; (2) flat on the door and back ends; and (3) model center of gravity over impact point at various locations of the model (door end, back end, near door seals, near tubular frame structure, center of panels). The test results and subsequent analysis of the data have been used to support the final design of TRUPACT-I and to determine the most damaging impact and puncture orientations for testing the full scale prototype

  13. Detailed puncture analyses tank cars : analysis of different impactor threats and impact conditions.

    Science.gov (United States)

    2013-03-01

    There has been significant research in recent years to analyze and improve the impact behavior and puncture resistance of railroad tank cars. Much of this research has been performed using detailed nonlinear finite element analyses supported by full ...

  14. Upper limb artery segmental occlusions due to chronic use of ergotamine combined with itraconazole, treated by thrombolysis

    Directory of Open Access Journals (Sweden)

    Nodari Franco

    2011-08-01

    Full Text Available Abstract Background The ergotamine tartrate associated with certain categories of drugs can lead to critical ischemia of the extremities. Discontinuation of taking ergotamine is usually sufficient for the total regression of ischemia, but in some cases it could be necessary thrombolytic and anticoagulant therapy to avoid amputation. Case report A woman of 62 years presented with a severe pain left forearm appeared 10 days ago, with a worsening trend. The same symptoms appeared after 5 days also in the right forearm. Physical examination showed the right arm slightly hypothermic, with radial reduced pulse in presence of reduced sensitivity. The left arm was frankly hypothermic, pulse less on radial and with an ulnar humeral reduced pulse, associated to a decreased sensitivity and motility. Clinical history shows a chronic headache for which the patient took a daily basis for years Cafergot suppository (equivalent to 3.2 mg of ergotamine. From about ten days had begun therapy with itraconazole for vaginal candidiasis. The Color-Doppler ultrasound shown arterial thrombosis of the upper limbs (humeral and radial bilateral, with minimal residual flow to the right and no signal on the humeral and radial left artery. Results Angiography revealed progressive reduction in size of the axillary artery and right humeral artery stenosis with right segmental occlusions and multiple hypertrophic collateral circulations at the elbow joint. At the level of the right forearm was recognizable only the radial artery, decreased in size. Does not recognize the ulnar, interosseous artery was thin. To the left showed progressive reduction in size of the distal subclavian and humeral artery, determined by multiple segmental steno-occlusion with collateral vessels serving only a thin hypotrophic interosseous artery. Arteriographic findings were compatible with systemic drug-induced disease. The immediate implementation of thrombolysis, continued for 26 hours, with

  15. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy

    International Nuclear Information System (INIS)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-01-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct

  16. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy.

    Science.gov (United States)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-04-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.

  17. Emergency Medicine Myths: Computed Tomography of the Head Prior to Lumbar Puncture in Adults with Suspected Bacterial Meningitis - Due Diligence or Antiquated Practice?

    Science.gov (United States)

    April, Michael D; Long, Brit; Koyfman, Alex

    2017-09-01

    Various sources purport an association between lumbar puncture and brainstem herniation in patients with intracranial mass effect lesions. Several organizations and texts recommend head computed tomography (CT) prior to lumbar puncture in selected patients. To review the evidence regarding the utility of obtaining head CT prior to lumbar puncture in adults with suspected bacterial meningitis. Observational studies report a risk of post-lumbar puncture brainstem herniation in the presence of intracranial mass effect (1.5%) that is significantly lower than that reported among all patients with bacterial meningitis (up to 13.3%). It is unclear from existing literature whether identifying patients with intracranial mass effect decreases herniation risk. Up to 80% of patients with bacterial meningitis experiencing herniation have no CT abnormalities, and approximately half of patients with intracranial mass effect not undergoing lumbar puncture herniate. Decision rules to selectively perform CT on only those individuals most likely to have intracranial mass effect lesions have not undergone validation. Despite recommendations for immediate antimicrobial therapy prior to imaging, data indicate an association between pre-lumbar puncture CT and antibiotic delays. Recent data demonstrate shortened door-to-antibiotic times and lower mortality from bacterial meningitis after implementation of new national guidelines, which restricted generally accepted CT indications by removing impaired mental status as imaging criterion. Data supporting routine head CT prior to lumbar puncture are limited. Physicians should consider selective CT for those patients at risk for intracranial mass effect lesions based on decision rules or clinical gestalt. Patients undergoing head CT must receive immediate antibiotic therapy. Published by Elsevier Inc.

  18. X-ray targeting puncture collagenase chemonucleolysis combined with injection of medical ozone for the treatment of lumbar disc herniation

    International Nuclear Information System (INIS)

    Yao Lin; Zhu Genfa

    2011-01-01

    Objective: To evaluate the clinical value of X-ray target puncture collagenase chemonucleolysis combined with injection of medical ozone for lumbar disc herniation. Methods: One thousand and sixty-two cases of lumbar disc herniation accepted collagenase chemonucleolysis combined with injection of medical ozone targeted by X-ray. The therapeutic effects after operation were analyzed. Results: Of all the 1062 cases, the effective rate of X-ray target puncture collagenase chemonucleolysis combined with injection of medical ozone was 95.3% at 3 months, 92.3% at 12 months, and 91.2% at 24 months after operation. Conclusion: X-ray target puncture collagenase chemonucleolysis combined with injection of medical ozone is a simple and safe method for the lumbar disc herniation. It also had fewer adverse reactions and better therapeutic effects. (authors)

  19. Therapeutic effects of visual standard channel combined with F4.8 visual puncture super-mini percutaneous nephrolithotomy on multiple renal calculi.

    Science.gov (United States)

    Cui, Zhenyu; Gao, Yanjun; Yang, Wenzeng; Zhao, Chunli; Ma, Tao; Shi, Xiaoqiang

    2018-01-01

    To evaluate the therapeutic effects of visual standard channel combined with F4.8 visual puncture super-mini percutaneous nephrolithotomy (SMP) on multiple renal calculi. The clinical data of 46 patients with multiple renal calculi treated in Affiliated Hospital of Hebei University from October 2015 to September 2016 were retrospectively analyzed. There were 28 males and 18 females aged from 25 to 65 years old, with an average of 42.6. The stone diameters were 3.0-5.2 cm, (4.3 ± 0.8) cm on average. F4.8 visual puncture-assisted balloon expansion was used to establish a standard channel. After visible stones were removed through nephroscopy combined with ultrasound lithotripsy, the stones of other parts were treated through F4.8 visual puncture SMP with holmium laser. Indices such as the total time of channel establishment, surgical time, decreased value of hemoglobin, phase-I stone clearance rate and surgical complications were summarized. Single standard channel was successfully established in all cases with the assistance of F4.8 visual puncture, of whom 24 were combined with a single microchannel, 16 were combined with double microchannels, and six were combined with three microchannels. All patients were placed with nephrostomy tube which was not placed in the microchannels. Both F5 double J tubes were placed after surgery. The time for establishing a standard channel through F4.8 visual puncture was (6.8 ± 1.8) min, and that for establishing a single F4.8 visual puncture microchannel was (4.5 ± 0.9) min. The surgical time was (92 ± 15) min. The phase-I stone clearance rate was 91.3% (42/46), and the decreased value of hemoglobin was (12.21 ± 2.5) g/L. There were 8 cases of postoperative fever which was relieved after anti-inflammatory treatment. Four cases had 0.5-0.8 cm of stone residue in the lower calyx, and all stones were discharged one month after surgery by in vitro shock wave lithotripsy combined with position nephrolithotomy, without stone

  20. Open Treatment of Blunt Injuries of Supra-Aortic Branches: Case Series.

    Science.gov (United States)

    Sladojevic, Milos; Markovic, Miroslav; Ilic, Nikola; Pejkic, Sinisa; Banzic, Igor; Djoric, Predrag; Koncar, Igor; Tomic, Ivan; Davidovic, Lazar

    2016-02-01

    Blunt injuries of the supra-aortic branches are rare entity, and majority of patients die before arrival at the hospital. Those who arrive alive require complex and fast procedure that requires sternotomy. We report 3 successfully managed cases. We report 3 patients with injury of supra-aortic branches. One was treated urgently due to longitudinal rupture on the posterior wall of innominate artery after car accident, and another 2 had chronic false aneurysm located at the very orifice of the right subclavian and left common carotid artery. In first and second patient bypass grafting with a hand-made, Y-shaped, 8-mm Dacron graft from the ascending aorta to the right common carotid and proximal right subclavian artery were performed, whereas in last 1 bypass grafting from the ascending aorta to the cervical part of the left common carotid artery was performed. In our facility, there were no possibilities for any endovascular treatment. When endovascular technology is not available, open surgical repair of blunt injuries of supra-aortic vessels can be performed without complications. No matter to that, endovascular and hybrid procedures should be considered whenever possible. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Call-Fleming Syndrome (Reversible Cerebral Artery Vasoconstriction and Aneurysm Associated with Multiple Recreational Drug Use

    Directory of Open Access Journals (Sweden)

    Doniel Drazin

    2013-01-01

    Full Text Available Drug abuse represents a significant health issue. Evidence suggests that recreational drug use has a direct effect on the cerebral vasculature and is of greater concern in those with undiagnosed aneurysms or vascular malformations. The authors report a case of thunderclap headache with a negative head CT and equivocal lumbar puncture after a drug-fueled weekend. The patient underwent diagnostic cerebral angiogram which demonstrated multisegmental, distal areas of focal narrowing of the middle, anterior, posterior, and posterior inferior cerebral artery and an incidental aneurysm. It is often difficult to determine the exact origin of symptoms; thus we were left with a bit of a chicken or the egg debate, trying to decipher which part came first. Either the aneurysm ruptured with associated concomitant vasospasm or it is a case of Call-Fleming syndrome (reversible cerebral artery vasoconstriction with an incidental aneurysm. The authors proposed their management and rationale of this complex case.

  2. Application of C-arm CT-guided targeted puncturing technique in performing non-vascular interventional biopsy or interventional therapy

    International Nuclear Information System (INIS)

    Li Zhen; Han Xinwei; Jiao Dechao; Ren Jianzhuang; Su Yu; Ye Hui

    2011-01-01

    Objective: to investigate the clinical value of C-arm CT-guided targeted puncturing technique in performing non, vascular interventional biopsy or interventional therapy. Methods: Thirty, one patients, who were encountered in authors' hospital during the period from July 2010 to September 2010, were involved in this study. C-arm CT-guided percutaneous targeted puncturing biopsy or interventional therapy was performed in all 31 patients. All patients had complete clinical data. The complications and positive rate of biopsy were recorded and analyzed. Results: Under C-arm CT-guidance, percutaneous interventional therapy was carried out in 13 patients. The interventional procedures included radiofrequency ablation therapy for hepatic cellular carcinoma (n=2), pelvic abscess draining (n=1), hepatic abscess draining (n=1), ethanol injection for liver cancer (n=4), sclerotic therapy with ethanol injection for renal cyst (n=2), sclerotic therapy with ethanol injection for liver cyst (n=2) and catheter-indwelling drainage for pancreatic pseudocyst (n=1). percutaneous interventional biopsy was performed in the remaining 18 cases, including liver (n=4), lung (n=7), mediastinum (n=2), bone and soft tissue (n=4) and neck mass (n=1). All the procedures were successfully accomplished, no technique, related complications occurred during the operation. For biopsy examination in 18 cases, the positive rate was 94.4% (17/18) and false, negative results was seen in one case with lung lesion. Conclusion: The percutaneous targeted puncturing technique with C, arm CT-guidance combines the advantages of both CT scanning and fluoroscopy. The use of real, time road, mapping function can effectively guide the puncturing and therapeutic management, which can not only optimize the workflow, save the operation time, but also improve the success rate and technical safety. Therefore, it is of great value to popularize this targeted puncturing technique. (authors)

  3. Study of the damage rate caused by intervertebral foramen type inside and outside and the pass of the intervertebral DRG RF puncture way.

    Science.gov (United States)

    Sun, Jiashu; Zhang, Haitao

    2014-09-01

    This paper was to analyze and contrast the damage rate on the thoracic segment different position of the dorsal root ganglion(dorsal root ganglion, DRG) caused by different puncture path in radiofrequency ablation, thus the best RF target way for the thoracic segment of different types of DRG was confirmed. According to the difference of puncture and ablation damage way, 14 segmental spinal specimens were randomly divided into three groups, and then conducted DRG radiofrequency damage on percutaneous puncture path according to the type of DRG position.The damage effect of different puncture path by the judgment standard of the result of pathology analyzed. The experiment showed that RF damage of group A were 72.58 ± 18.88%, 54.16 ± 24.84% and 32.85 ± 28.11%; that of group B were 771.86 ± 15.15% and 72.02 ± 17.86%, 57.14 ± 18.02% and 52.47 ± 20.64%, 68.75 ± 14.63% and 71.78 ± 16.00%; and that of group C were 82.46 ± 14.10%, 81.53 ± 11.81% and 80.83 ± 13.33%. It was concluded that the singleness of DRG puncture route is one of the important reasons for the poor thoracic segments DRG radiofrequency (RF) ablation effect. While according to the type of DRG different positions with double joint puncture path can significantly improve the rate of DRG RF damage.

  4. The exchange algebra for Liouville theory on punctured Riemann sphere

    International Nuclear Information System (INIS)

    Shen Jianmin; Sheng Zhengmao

    1991-11-01

    We consider in this paper the classical Liouville field theory on the Riemann sphere with n punctures. In terms of the uniformization theorem of Riemann surface, we show explicitly the classical exchange algebra (CEA) for the chiral components of the Liouville fields. We find that the matrice which dominate the CEA is related to the symmetry of the Lie group SL(n) in a nontrivial manner with n>3. (author). 10 refs

  5. "True" posterior communicating aneurysms: Three cases, three strategies.

    Science.gov (United States)

    Nery, Breno; Araujo, Ricardo; Burjaili, Bruno; Smith, Timothy R; Rodrigues, Jose Carlos; Silva, Marcelo Nery

    2016-01-01

    The authors provide a review of true aneurysms of the posterior communicating artery (PCoA). Three cases admitted in our hospital are presented and discussed as follows. First patient is a 51-year-old female presenting with a Fisher II, Hunt-Hess III (headache and confusion) subarachnoid hemorrhage (SAH) from a ruptured true aneurysm of the right PCoA. She underwent a successful ipsilateral pterional craniotomy for aneurysm clipping and was discharged on postoperative day 4 without neurological deficit. Second patient is a 53-year-old female with a Fisher I, Hunt-Hess III (headache, mild hemiparesis) SAH and multiple aneurisms, one from left ophthalmic carotid artery and one (true) from right PCoA. These lesions were approached and successfully treated by a single pterional craniotomy on the left side. The patient was discharged 4 days after surgery, with complete recovery of muscle strength during follow-up. Third patient is a 69-year-old male with a Fisher III, Hunt-Hess III (headache and confusion) SAH, from a true PCoA on the right. He had a left subclavian artery occlusion with flow theft from the right vertebral artery to the left vertebral artery. The patient underwent endovascular treatment with angioplasty and stent placement on the left subclavian artery that resulted in aneurysm occlusion. In conclusion, despite their seldom occurrence, true PCoA aneurysms can be successfully treated with different strategies.

  6. Mycobacterium ulcerans low infectious dose and mechanical transmission support insect bites and puncturing injuries in the spread of Buruli ulcer.

    Science.gov (United States)

    Wallace, John R; Mangas, Kirstie M; Porter, Jessica L; Marcsisin, Renee; Pidot, Sacha J; Howden, Brian; Omansen, Till F; Zeng, Weiguang; Axford, Jason K; Johnson, Paul D R; Stinear, Timothy P

    2017-04-01

    Addressing the transmission enigma of the neglected disease Buruli ulcer (BU) is a World Health Organization priority. In Australia, we have observed an association between mosquitoes harboring the causative agent, Mycobacterium ulcerans, and BU. Here we tested a contaminated skin model of BU transmission by dipping the tails from healthy mice in cultures of the causative agent, Mycobacterium ulcerans. Tails were exposed to mosquito (Aedes notoscriptus and Aedes aegypti) blood feeding or punctured with sterile needles. Two of 12 of mice with M. ulcerans contaminated tails exposed to feeding A. notoscriptus mosquitoes developed BU. There were no mice exposed to A. aegypti that developed BU. Eighty-eight percent of mice (21/24) subjected to contaminated tail needle puncture developed BU. Mouse tails coated only in bacteria did not develop disease. A median incubation time of 12 weeks, consistent with data from human infections, was noted. We then specifically tested the M. ulcerans infectious dose-50 (ID50) in this contaminated skin surface infection model with needle puncture and observed an ID50 of 2.6 colony-forming units. We have uncovered a biologically plausible mechanical transmission mode of BU via natural or anthropogenic skin punctures.

  7. Mycobacterium ulcerans low infectious dose and mechanical transmission support insect bites and puncturing injuries in the spread of Buruli ulcer.

    Directory of Open Access Journals (Sweden)

    John R Wallace

    2017-04-01

    Full Text Available Addressing the transmission enigma of the neglected disease Buruli ulcer (BU is a World Health Organization priority. In Australia, we have observed an association between mosquitoes harboring the causative agent, Mycobacterium ulcerans, and BU. Here we tested a contaminated skin model of BU transmission by dipping the tails from healthy mice in cultures of the causative agent, Mycobacterium ulcerans. Tails were exposed to mosquito (Aedes notoscriptus and Aedes aegypti blood feeding or punctured with sterile needles. Two of 12 of mice with M. ulcerans contaminated tails exposed to feeding A. notoscriptus mosquitoes developed BU. There were no mice exposed to A. aegypti that developed BU. Eighty-eight percent of mice (21/24 subjected to contaminated tail needle puncture developed BU. Mouse tails coated only in bacteria did not develop disease. A median incubation time of 12 weeks, consistent with data from human infections, was noted. We then specifically tested the M. ulcerans infectious dose-50 (ID50 in this contaminated skin surface infection model with needle puncture and observed an ID50 of 2.6 colony-forming units. We have uncovered a biologically plausible mechanical transmission mode of BU via natural or anthropogenic skin punctures.

  8. Esternotomia mediana como via preferencial na anastomose de Blalock-Taussig modificada

    Directory of Open Access Journals (Sweden)

    Rogério ABRAHÃO

    1997-04-01

    Full Text Available A abordagem usual para a realização da anastomose de Blalock-Taussig modificada (ABTM tem sido a toracotomia lateral. Esta via acarreta necessariamente trauma ao parênquima pulmonar e acesso difícil por ocasião da operação definitiva. A esternotomia mediana (EM apresenta-se como uma alternativa com certas vantagens. Este trabalho visa avaliar a viabilidade técnica e os resultados da realização da ABTM por EM. Dez pacientes foram submetidos a esta técnica, interpondo-se enxertos de PTFE. A mortalidade imediata foi de 30%, e a tardia de 10%. Complicação imediata ocorreu em 10%. O tempo médio de internação foi 7,0 ± 0,5 dias. A variação da saturação da hemoglobina pré e pós-operatória foi 27,5 ± 11,7% (pThe usual approach for systemic-pulmonary shunts has been right or left thoracotomy and interposition of a PTFE vascular graft between the subclavian and pulmonary arteries. This approach, necessarily causes, trauma to the lungs and some difficulty for dissection and ligation later during definitive surgical correction. Median sternotomy has been used occasionally for right subclavian-pulmonary artery anastomosis with certain advantages over thoracotomy. In this series, 10 patients were submitted to systemic-pulmonary modified Blalock-Taussig shunts by median sternotomy as the first choice. There have been no technical difficulties. The grafts were anastomosed to the right subclavian artery or brachiocephalic trunk. The right pulmonary artery was preferred, but when infeasible, this side of the shunt was made to the pulmonary trunk or left pulmonary artery. There have been 3 early and 1 late death, unrelated to the shunt. Arterial saturation improved by 27.5 ± 11.7% (p<0.001 post-operatively. This technique is viable, with advantages over lateral approach due to easier access, avoiding lung trauma, permitting surgical alternatives and canulation if needed and may facilitate dissection for later ligation.

  9. Feasibility and Safety of Vascular Closure Devices in an Antegrade Approach to Either the Common Femoral Artery or the Superficial Femoral Artery

    Energy Technology Data Exchange (ETDEWEB)

    Gutzeit, Andreas, E-mail: andreas.gutzeit@ksw.ch; Schie, Bram van, E-mail: Bram.vanschie@hotmail.com; Schoch, Eric, E-mail: eric.schoch@ksw.ch [Cantonal Hospital Winterthur, Department of Radiology (Switzerland); Hergan, Klaus, E-mail: k.hergan@salk.at [Paracelsus Medical University Salzburg, Department of Radiology (Austria); Graf, Nicole, E-mail: graf@biostatistics.ch; Binkert, Christoph A., E-mail: christoph.binkert@ksw.ch [Cantonal Hospital Winterthur, Department of Radiology (Switzerland)

    2012-10-15

    Introduction: The purpose of the present study was to analyze complications following antegrade puncture of the common femoral artery (CFA) and the superficial femoral artery (SFA) using vascular closure systems (VCS). Methods: A single-center, retrospective study was performed after obtaining approval from the institutional review board and informed consent from all patients. At our center, the CFA or SFA are used for arterial access. All patients were evaluated clinically on the same day. If there was any suspicion of an access site problem, Duplex ultrasound was performed. Results: Access location was the CFA in 50 patients and the SFA in 130 patients. The sheath size ranged from 4F to 10F. Two patients had to be excluded because of lack of follow-up. Successful hemostasis was achieved in 162 of 178 cases (91 %). The following complications were observed in 16 patients (8.9 %): 4 pseudoaneurysms (2.2 %), 11 hematomas (6.2 %), and 1 vascular occlusion (0.5 %). The two pseudoaneurysms healed spontaneously, in one case an ultrasound-guided thrombin injection was performed, and one aneurysm was compressed manually. No further medical therapy was needed for the hematomas. The one vascular occlusion was treated immediately with angioplasty using a contralateral approach. No significant difference was noted between the CFA and the SFA group with respect to complications (p = 1.000). Conclusions: The use of closure devices for an antegrade approach up to 10F is feasible and safe. No differences in low complication rates were observed between CFA and SFA.

  10. Feasibility and Safety of Vascular Closure Devices in an Antegrade Approach to Either the Common Femoral Artery or the Superficial Femoral Artery

    International Nuclear Information System (INIS)

    Gutzeit, Andreas; Schie, Bram van; Schoch, Eric; Hergan, Klaus; Graf, Nicole; Binkert, Christoph A.

    2012-01-01

    Introduction: The purpose of the present study was to analyze complications following antegrade puncture of the common femoral artery (CFA) and the superficial femoral artery (SFA) using vascular closure systems (VCS). Methods: A single-center, retrospective study was performed after obtaining approval from the institutional review board and informed consent from all patients. At our center, the CFA or SFA are used for arterial access. All patients were evaluated clinically on the same day. If there was any suspicion of an access site problem, Duplex ultrasound was performed. Results: Access location was the CFA in 50 patients and the SFA in 130 patients. The sheath size ranged from 4F to 10F. Two patients had to be excluded because of lack of follow-up. Successful hemostasis was achieved in 162 of 178 cases (91 %). The following complications were observed in 16 patients (8.9 %): 4 pseudoaneurysms (2.2 %), 11 hematomas (6.2 %), and 1 vascular occlusion (0.5 %). The two pseudoaneurysms healed spontaneously, in one case an ultrasound-guided thrombin injection was performed, and one aneurysm was compressed manually. No further medical therapy was needed for the hematomas. The one vascular occlusion was treated immediately with angioplasty using a contralateral approach. No significant difference was noted between the CFA and the SFA group with respect to complications (p = 1.000). Conclusions: The use of closure devices for an antegrade approach up to 10F is feasible and safe. No differences in low complication rates were observed between CFA and SFA.

  11. Gadolinium enhancement of spinal subdural collection on magnetic resonance imaging after lumbar puncture

    International Nuclear Information System (INIS)

    Teksam, Mehmet; Casey, Sean O.; McKinney, Alexander; Michel, Eduard; Truwit, Charles L.

    2003-01-01

    We report a 35-year-old male with an unusual contrast-enhancing sterile spinal subdural collection on magnetic resonance imaging (MRI), apparently occurring as a complication of lumbar puncture. Follow-up MRI after 4 weeks demonstrated spontaneous resolution of the collection without intervening treatment. (orig.)

  12. Aortic intracardiac echocardiography-guided septal puncture during mitral valvuloplasty.

    Science.gov (United States)

    Akkaya, Emre; Vuruskan, Ertan; Zorlu, Ali; Sincer, Isa; Kucukosmanoglu, Mehmet; Ardic, Idris; Yilmaz, Mehmet Birhan

    2014-01-01

    Transoesophageal echocardiography (TEE) and venous intracardiac echocardiography (ICE) are traditionally used to visualize the interatrial septum (IAS) and the tenting effect of the fossa ovalis in patients undergoing percutaneous balloon mitral valvuloplasty (PBMV). The aim of the present study was to assess the comparative efficacy and safety of arterial (intra-aortic) ICE and venous ICE, compared with TEE (traditional approach), in the patients undergoing PBMV. TEE, aortic ICE, and venous ICE were consecutively performed in 50 patients (40 ± 9 years, 86% female). The images of intracardiac structures were obtained from both aortic and right atrial loci. The IAS was visualized using TEE, aortic ICE, and venous ICE. The mean mitral valve area was 1.14 ± 0.2 cm(2), and the mean left atrial volume index was 57.5 ± 12 mL/m(2). The mean size of the visualized septal length was 48 ± 5 mm by TEE, 51 ± 5 mm by aortic ICE, and 33 ± 6 mm by venous ICE. The Bland-Altman test indicated that the 95% limits of agreement for the measurement of septal diameter ranged from -11.0 to +5.9 mm (mean -2.5 mm) between TEE and aortic ICE, -2.8 to +33.5 mm (mean +15.3 mm) between TEE and venous ICE, and -36.6 to +0.8 mm (mean -17.9 mm) between venous and aortic ICE. Standard venous ICE generally tended to yield smaller values compared with TEE and aortic ICE for the measurement of septal length. Furthermore, the view of fossa ovalis and 'tenting effect' was optimal in 11 patients on venous ICE; however, the fossa ovalis and tip of the needle were well visualized in all patients on aortic ICE (P < 0.001). There were no major complications with the use of aortic ICE. Aortic ICE is a superior alternative to venous ICE and facilitates trans-septal puncture in patients with mitral stenosis.

  13. Patent ductus arteriosus closure using an Amplatzer™ ventricular septal defect closure device

    OpenAIRE

    Fernando, Rajeev; Koranne, Ketan; Loyalka, Pranav; Kar, Biswajit; Gregoric, Igor

    2013-01-01

    The ductus arteriosus originates from the persistence of the distal portion of the left sixth aortic arch. It connects the descending aorta (immediately distal to the left subclavian artery) to the roof of the main pulmonary artery, near the origin of the left pulmonary artery. Persistence of the duct beyond 48 h after birth is abnormal and results in patent ductus arteriosus (PDA). PDA is rare in adults because it is usually discovered and treated in childhood. Mechanical closure remains the...

  14. Equilibrium initial data for moving puncture simulations: the stationary 1 + log slicing

    International Nuclear Information System (INIS)

    Baumgarte, T W; Matera, K; Etienne, Z B; Liu, Y T; Shapiro, S L; Taniguchi, K; Murchadha, N O

    2009-01-01

    We discuss a 'stationary 1 + log' slicing condition for the construction of solutions to Einstein's constraint equations. For stationary spacetimes, these initial data give a stationary foliation when evolved with 'moving puncture' gauge conditions that are often used in black hole evolutions. The resulting slicing is time independent and agrees with the slicing generated by being dragged along a timelike Killing vector of the spacetime. When these initial data are evolved with moving puncture gauge conditions, numerical errors arising from coordinate evolution should be minimized. While these properties appear very promising, suggesting that this slicing condition should be an attractive alternative to, for example, maximal slicing, we demonstrate in this paper that solutions can be constructed only for a small class of problems. For binary black hole initial data, in particular, it is often assumed that there exists an approximate helical Killing vector that generates the binary's orbit. We show that 1 + log slices that are stationary with respect to such a helical Killing vector cannot be asymptotically flat, unless the spacetime possesses an additional axial Killing vector.

  15. Ballistic Puncture Self-Healing Polymeric Materials

    Science.gov (United States)

    Gordon, Keith L.; Siochi, Emilie J.; Yost, William T.; Bogert, Phil B.; Howell, Patricia A.; Cramer, K. Elliott; Burke, Eric R.

    2017-01-01

    Space exploration launch costs on the order of $10,000 per pound provide an incentive to seek ways to reduce structural mass while maintaining structural function to assure safety and reliability. Damage-tolerant structural systems provide a route to avoiding weight penalty while enhancing vehicle safety and reliability. Self-healing polymers capable of spontaneous puncture repair show promise to mitigate potentially catastrophic damage from events such as micrometeoroid penetration. Effective self-repair requires these materials to quickly heal following projectile penetration while retaining some structural function during the healing processes. Although there are materials known to possess this capability, they are typically not considered for structural applications. Current efforts use inexpensive experimental methods to inflict damage, after which analytical procedures are identified to verify that function is restored. Two candidate self-healing polymer materials for structural engineering systems are used to test these experimental methods.

  16. Successful use of nitrous oxide during lumbar punctures: A call for nitrous oxide in pediatric oncology clinics.

    Science.gov (United States)

    Livingston, Mylynda; Lawell, Miranda; McAllister, Nancy

    2017-11-01

    Numerous reports describe the successful use of nitrous oxide for analgesia in children undergoing painful procedures. Although shown to be safe, effective, and economical, nitrous oxide use is not yet common in pediatric oncology clinics and few reports detail its effectiveness for children undergoing repeated lumbar punctures. We developed a nitrous oxide clinic, and undertook a review of pediatric oncology lumbar puncture records for those patients receiving nitrous oxide in 2011. No major complications were noted. Minor complications were noted in 2% of the procedures. We offer guidelines for establishing such a clinic. © 2017 Wiley Periodicals, Inc.

  17. Renal Artery Embolization - A First Line Treatment Option For End-Stage Hydronephrosis

    International Nuclear Information System (INIS)

    Mitra, Kakali; Prabhudesai, Vikramaditya; James, R. Lester; Jones, Robert W. A.; French, Michael E.; Cowling, Mark; West, David J.

    2004-01-01

    Conventionally poorly functioning hydronephrotic kidneys have been removed if they are symptomatic. In our unit, patients are offered renal artery embolization as an alternative treatment option. Patients and Methods: Fifteen patients (11 male, 4 female) with a mean age of 32.9 yr (20-51 yrs) have undergone renal artery embolization for symptomatic hydronephrosis with poor function. Mean follow-up was 64.13 weeks (range 14-200). All patients had loin pain and hydronephrosis. Twelve patients had primary pelvi-ureteric junction obstruction (PUJO). Two patients had poorly functioning hydronephrotic kidneys secondary to chronic calculous obstruction. One patient had chronic pain in an obstructed but reasonably functioning kidney following a previous pyeloplasty for PUJO which demanded intervention. Mean split function on renography was 11% (range 0-46%). Selective renal artery embolization was carried out under antibiotic cover using a 7 Fr balloon occlusion catheter and absolute alcohol, steel coils, and polyvinyl alcohol particles.Results: Nine patients developed post-embolization syndrome of self-limiting pain and pyrexia with no evidence of sepsis. One patient required readmission with this condition. One patient developed a hematoma at the puncture site. Mean hospital stay was 2.3 days. Fourteen patients are happy with the result and are completely pain free. One patient has minor discomfort but is delighted with the result. Nine patients have had follow-up ultrasound confirming resolution of the hydronephrosis. Conclusion: Renal artery embolization is an effective, safe, well-tolerated minimally invasive treatment option in end-stage hydronephrosis and we routinely offer it as an alternative to nephrectomy

  18. Retroperitoneal hemorrhage from an unrecognized puncture of the lumbar right segmental artery during lumbar chemical sympathectomy: diagnosis and management.

    Science.gov (United States)

    Shin, Ho-Jin; Choi, Yun-Mi; Kim, Hye-Jin; Lee, Sun-Jae; Yoon, Seok-Hyun; Kim, Kyung-Hoon

    2014-12-01

    Lumbar chemical sympathectomy has been performed using fluoroscopic guidance for needle positioning. An 84 year old woman with atherosclerosis obliterans was referred to the pain clinic for intractable cold allodynia of her right foot. A thermogram showed decreased temperature of both feet compared with temperatures above both ankles. The patient agreed to undergo lumbar chemical sympathectomy using fluoroscopy after being informed of the associated risks of nerve injury, hemorrhage, infection, transient back pain, and transient hypotension. During the procedure and three hours afterward, no abnormal signs or symptoms were found except an increase in right leg temperature. The patient was ambulatory after the procedure. However, one day after undergoing lumbar chemical sympathectomy, she visited our emergency department for abdominal discomfort and postural dizziness. Her blood pressure was 80/50 mmHg, and flank tenderness was noted. Retroperitoneal hemorrhage from the second right lumbar segmental artery was shown on computed tomography and angiography. Vital signs were stabilized immediately after embolization into the right lumbar segmental artery. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Percutaneous treatment of critical lower limb ischemia in patients with obstruction of the crural arteries

    International Nuclear Information System (INIS)

    Falkowski, A.; Rutkowski, D.; Poncyliusz, W.; Sienko, J.

    2006-01-01

    This article describes the application of percutaneous transluminal angioplasty (PTA) in the treatment of crural artery obstruction in patients with critical lower limb ischemia. In 17 patients, 24 PTAs of crural artery obstructions were performed. The clinical material consisted of 9 men and 8 women, whose mean age was 72 years (range 54-85 years). 11 patients were classified in clinical stage Fontaine IV, and 6 in stage III. The obstructions were from 3 to 21 cm (mean 6 cm). In 8 cases, PTA of the femoropopliteal segment was also carried out. The risk factors and comorbidities included diabetes 10 cases (58.8%), hypertension 9 cases (56%), ischemic heart disease 8 cases (50%), hyperlipidaemia 7 cases (43.8%), cerebrovascular diseases 3 cases (18.8%), and cigarette smoking 6 cases (37.5%). Technical success was defined as restoration of the artery along its whole length to the foot. Pain relief at rest and healing of trophic lesions at 30-day follow-up were recognized as a good outcome. Technical success was achieved in 12 patients (70.6%). In 2 cases the patency was only restored in the proximal part of the artery (12.5%). In 3 cases (17.6%) the procedure failed. In one case acute occlusion of the artery occurred. In 2 cases the obstruction was not successfully passed with a guidewire. In 4 cases hematoma was found at the puncture site, without clinical consequences. In 13 patients (76.4%) clinical success was achieved. Percutaneous transluminal angioplasty is an effective and relatively safe method of treatment of patients with critical limb ischemia caused by obstruction of the crural arteries. (author)

  20. Maximal muscular vascular conductances during whole body upright exercise in humans

    DEFF Research Database (Denmark)

    Calbet, J A L; Jensen-Urstad, M; Van Hall, Gerrit

    2004-01-01

    76% of VO(2,max) and at VO(2,max) with different techniques: diagonal stride (combined arm and leg exercise), double poling (predominantly arm exercise) and leg skiing (predominantly leg exercise). During submaximal exercise cardiac output (26-27 l min(-1)), mean blood pressure (MAP) (approximately......That muscular blood flow may reach 2.5 l kg(-1) min(-1) in the quadriceps muscle has led to the suggestion that muscular vascular conductance must be restrained during whole body exercise to avoid hypotension. The main aim of this study was to determine the maximal arm and leg muscle vascular...... (VO(2,max)) 5.1 +/- 0.1 l min(-1) participated in the study. Femoral and subclavian vein blood flows, intra-arterial blood pressure, cardiac output, as well as blood gases in the femoral and subclavian vein, right atrium and femoral artery were determined during skiing (roller skis) at approximately...

  1. Axillo-axillary Bypass Grafting for Proximal Subclavian Artery ...

    African Journals Online (AJOL)

    1974-10-26

    Oct 26, 1974 ... 'dizzy spells, with tinnitus, which came on without warning and associated with a feeling of syncope. These episodes were usually transient and on occasions were definitely related to rotaton of her neck. Examination showed a weak left radial pulse with a blood pressure of 105/80 mmHg compared with ...

  2. Anatomical Study of Subclavian Artery and Its Branches

    Directory of Open Access Journals (Sweden)

    zahed Safikhani

    2006-02-01

    Conclusion: For preserving the integrity of important structures in the base of the neck, especially thyroid gland in surgery, this vascular variations are presented to physicians to keep in mind that such variations exists during diagnostic investigation and surgical procedures of the neck. An awareness of these variations is important, because this area in used for diagnostic and surgical procedures.

  3. Anomalous Origin of the Subclavian Artery Associated with ...

    African Journals Online (AJOL)

    Thallium, insulin, sulphonamides and other compounds as well as lack of riboflavine produce phocomelia-like malformations in experimental animals while maternal infection such as rubella is teratogenic in humans, but evidence that it causes phocomelia is not well established. Fig. 3. Arteriogram with injection of contrast ...

  4. [The use of low-frequency magnetotherapy and EHF puncture in the combined treatment of arterial hypertension in vibration-induced disease].

    Science.gov (United States)

    Drobyshev, V A; Filippova, G N; Loseva, M I; Shpagina, L A; Shelepova, N V; Zhelezniak, M S

    2000-01-01

    Combination of EHF therapy + magnetotherapy + drugs results in faster and persistent hypotensive and analgetic effect compared to standard drug therapy, potentiates action of vascular drugs on cerebral and peripheral circulation, reduces dose of hypotensive drugs in patients with arterial hypertension and vibration disease.

  5. Comparison of cutting and pencil-point spinal needle in spinal anesthesia regarding postdural puncture headache

    Science.gov (United States)

    Xu, Hong; Liu, Yang; Song, WenYe; Kan, ShunLi; Liu, FeiFei; Zhang, Di; Ning, GuangZhi; Feng, ShiQing

    2017-01-01

    Abstract Background: Postdural puncture headache (PDPH), mainly resulting from the loss of cerebral spinal fluid (CSF), is a well-known iatrogenic complication of spinal anesthesia and diagnostic lumbar puncture. Spinal needles have been modified to minimize complications. Modifiable risk factors of PDPH mainly included needle size and needle shape. However, whether the incidence of PDPH is significantly different between cutting-point and pencil-point needles was controversial. Then we did a meta-analysis to assess the incidence of PDPH of cutting spinal needle and pencil-point spinal needle. Methods: We included all randomly designed trials, assessing the clinical outcomes in patients given elective spinal anesthesia or diagnostic lumbar puncture with either cutting or pencil-point spinal needle as eligible studies. All selected studies and the risk of bias of them were assessed by 2 investigators. Clinical outcomes including success rates, frequency of PDPH, reported severe PDPH, and the use of epidural blood patch (EBP) were recorded as primary results. Results were evaluated using risk ratio (RR) with 95% confidence interval (CI) for dichotomous variables. Rev Man software (version 5.3) was used to analyze all appropriate data. Results: Twenty-five randomized controlled trials (RCTs) were included in our study. The analysis result revealed that pencil-point spinal needle would result in lower rate of PDPH (RR 2.50; 95% CI [1.96, 3.19]; P < 0.00001) and severe PDPH (RR 3.27; 95% CI [2.15, 4.96]; P < 0.00001). Furthermore, EBP was less used in pencil-point spine needle group (RR 3.69; 95% CI [1.96, 6.95]; P < 0.0001). Conclusions: Current evidences suggest that pencil-point spinal needle was significantly superior compared with cutting spinal needle regarding the frequency of PDPH, PDPH severity, and the use of EBP. In view of this, we recommend the use of pencil-point spinal needle in spinal anesthesia and lumbar puncture. PMID:28383416

  6. Technical compliance to standard guidelines for lumbar puncture and myelography: survey of academic neuroradiology attendings and fellows.

    Science.gov (United States)

    Zhang, Yi C; Chandler, Alexander J; Kagetsu, Nolan J

    2014-05-01

    To assess technical compliance among neuroradiology attendings and fellows to standard guidelines for lumbar puncture and myelography to minimize procedural complications such as iatrogenic meningitis and spinal headache. We surveyed academic neuroradiology attendings and fellows in the e-mail directory of the Association of Program Directors in Radiology. We queried use of face masks, use of noncutting needles, and dural puncture practices. All data were collected anonymously. A total of 110 survey responses were received: 75 from neuroradiology attendings and 34 from fellows, which represents a 14% response rate from a total of 239 fellows. Forty-seven out of 101 (47%) neuroradiologists do not always wear a face mask during myelograms, and 50 out of 105(48%) neuroradiologists do not always wear a face mask during lumbar punctures, placing patients at risk for iatrogenic meningitis. Ninety-six out of 106 neuroradiologists (91%) use the Quincke cutting needle by default, compared to only 17 out of 109 neuroradiologists (16%) who have ever used noncutting needles proven to reduce spinal headache. Duration of postprocedure bed rest does not influence incidence of spinal headache and may subject patients to unnecessary monitoring. Only 15 out of 109 (14%) neuroradiologists in our study do not prescribe bed rest. There was no statistically significant difference in practice between attendings and fellows. Iatrogenic meningitis and spinal headache are preventable complications of dural puncture that neuroradiologists can minimize by conforming to procedural guidelines. Wearing face masks and using noncutting spinal needles will reduce patient morbidity and lower hospitalization costs associated with procedural complications. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  7. Echocolor Doppler morpho-functional study of the jugulo-subclavian confluence in chronic cerebro-spinal venous insufficiency and multiple sclerosis patients.

    Science.gov (United States)

    Mandolesi, Sandro; d'Alessandro, Aldo; Desogus, Antonello Ignazio; Ciccone, Marco Matteo; Zito, Annapaola; Stammegna, Immacolata; Niglio, Tarcisio; Orsini, Augusto; Mandolesi, Dimitri; d'Alessandro, Alessandro; Revelli, Luca

    2017-01-01

    The aim of this work is to measure the mean diameter of the confluence jugulo- subclavian, the impact of different types of jugular confluences and the correlation between the types of confluences and the Valsalva maneuver (jugular reflux) in subjects with Chronic Cerebro-Spinal Venous Insufficiency (CCSVI) and Multiple Sclerosis. We investigated by Echo-Color-Doppler (ECD) 103 subjects (67 F 36M) of mean age 45 ± 12 years (a minimum of 22 to a maximum of 79 years, with a median of 44 and a modal value 42 years), mean EDSS of 4.7 and average disease duration of 12 years. The 103 right jugular veins investigated had an average diameter of 8.4 ± 2.4 mm (minimum 4.0, maximum 14.9 mm; median 7.9; modal value 7.6 mm). Three form types were found: 56 cylindrical, 29 conical and 18 funnel. Valsalva maneuver was positive in 30 patients. The 103 left jugular investigated had an average diameter of 8.9 ± 2.4 mm (minimum 2.8, maximum 14.4 mm; median of 8.8; modal value 8.7 mm). The form types were found: 42 cylindrical, 45 conical and 16 funnel. Valsalva maneuver was positive in 30 patients. The mean diameter of the jugular veins was 8.7 mm. Internal jugular veins with cylindrical morphology have a diameter smaller than other forms; this difference is statistically significant. The different morphology of the jugular vein confluence does not increase the possibility of a reflux because the positive Valsalva maneuvers are not statistically significant when compared to the various types. CCSVI, EchoColorDoppler Map, Jugulo-Subclavian Confluence Diameter.

  8. Classical and quantum Liouville theory on the Riemann sphere with n>3 punctures (III)

    International Nuclear Information System (INIS)

    Shen Jianmin; Sheng Zhengmao; Wang Zhonghua

    1992-02-01

    We study the Classical and Quantum Liouville theory on the Riemann sphere with n>3 punctures. We get the quantum exchange algebra relations between the chiral components in the Liouville theory from our assumption on the principle of quantization. (author). 5 refs

  9. Cumulative Effect of Repeated Brief Cerebral Ischemia

    Science.gov (United States)

    1991-12-14

    in this process. Rats were prepared for experiment under halothane anesthesia with trach; ostomy , ligation of both subclavian arteries, cannulation of...did, beyond ordinary surgical morbidity and electronic recording problems. All have finally been mastered, and we are hopeful that the mastery will be

  10. Laparo- and thoracoscopic aortic aneurysm neck optimization and treatment of potential endoleaks type IA and II in a porcine model

    DEFF Research Database (Denmark)

    Kloster, Brian Ozeraitis; Lund, Lars; Lindholt, Jes S.

    2016-01-01

    , externally placed collars/aneuwraps around the proximal AAA neck and just below the left subclavian artery and division of the aortic side branches were carried out laparo-and thoracoscopically. Results: For the laparoscopic and thoracoscopic procedures respectively, mean operative time was 143 ± 41 min...

  11. Challenging the wisdom of puncture at the calyceal fornix in percutaneous nephrolithotripsy: feasibility and safety study with 137 patients operated via a non-calyceal percutaneous track.

    Science.gov (United States)

    Kyriazis, Iason; Kallidonis, Panagiotis; Vasilas, Marinos; Panagopoulos, Vasilios; Kamal, Wissam; Liatsikos, Evangelos

    2017-05-01

    To present our experience with a central, non-calyceal puncture protocol for percutaneous nephrolithotripsy (PCNL) in an attempt to challenge the opinion of worldwide adopted calyceal puncture as the less traumatic site of percutaneous entrance into the collecting system. During 2012, a total of 137 consecutive, unselected patients were subjected to PCNL in our department. Non-calyceal punctures were performed to all cases and followed by subsequent track dilations up to 30 Fr. Perioperative and postoperative data were prospectively collected and analyzed. Mean operative time (from skin puncture to nephrostomy tube placement) was 48 min. Patients with single, multiple and staghorn stones had primary stone-free rates of 89.2, 80.4 and 66.7 % after PCNL, respectively. The overall complication rate was 10.2 %, while bleeding complications were minimal. Only 4 patients (2.9 %) required blood transfusion. Five patients (3.6 %) had Clavien Grade IIIa complications requiring an intervention for their management and none Grade IV or V. Despite the absence of evidence that non-calyceal percutaneous tracts could be a risk factor for complications, the concept of calyceal puncture has been worldwide adopted by PCNL surgeons as the sole safe percutaneous entrance into the collective system. Based on our experience, other pathways than the worldwide recognized rule, calyceal puncture, are possible and probably not as dangerous as has been previously stated.

  12. Radial pseudoaneurysm following diagnostic coronary angiography

    Directory of Open Access Journals (Sweden)

    Shankar Laudari

    2015-06-01

    Full Text Available The radial artery access has gained popularity as a method of diagnostic coronary catheterization compared to femoral artery puncture in terms of vascular complications and early ambulation. However, very rare complication like radial artery pseudoaneurysm may occur following cardiac catheterization which may give rise to serious consequences. Here, we report a patient with radial pseudoaneurysm following diagnostic coronary angiography. Adequate and correct methodology of compression of radial artery following puncture for maintaining hemostasis is the key to prevention.DOI: http://dx.doi.org/10.3126/jcmsn.v10i3.12776 Journal of College of Medical Sciences-Nepal, 2014, Vol-10, No-3, 48-50

  13. Variations of the aortic arch - a study on the most common branching patterns

    International Nuclear Information System (INIS)

    Muller, Marguerite; Schmitz, Bernd L; Schick, Melanie; Schloetzer, Wiebke; Pauls, Sandra; Roehrer, Stefan; Kapapa, Thomas

    2011-01-01

    Background: Anatomical variants of the aortic arch and its branching patterns often appear as an incidental finding during routine computed tomography (CT) scanning. These variations can be of relevance when performing angiography or endovascular interventions and may cause symptoms such as dysphagia. Purpose: To analyze common anatomical variations found within the arteries originating from the aortic arch in patients using contrast CT imaging techniques. Material and Methods: A total of 2033 contrast CT scans were analyzed. To obtain a truly representative sample, cases were chosen from different hospital departments without previous knowledge of the patient history. Results: The total percentage of variations within the analyzed patients was 13.3%. In 8.0% a truncus bicaroticus was found. 4.2% of the patients showed a left vertebral artery originating directly from the aortic arch, mostly proximal, and in 1 case distal to the left subclavian artery. In 1.0% we found an aberrant right subclavian artery. We also found a single case of a right descending aortic arch. Conclusion: Variations of the aortic arch and its branching are frequently found, mostly as an incidental finding during routine diagnostic scanning. A contrast-enhanced CT scan is a good method with which to study the aortic arch and its associated branching pattern

  14. Variations of the aortic arch - a study on the most common branching patterns

    Energy Technology Data Exchange (ETDEWEB)

    Muller, Marguerite; Schmitz, Bernd L; Schick, Melanie; Schloetzer, Wiebke (Dept. of Diagnostic and Interventional Radiology, Section Neuroradiology, Univ. Ulm (Germany)), email: marguerite.mueller@uni-ulm.de; Pauls, Sandra (Dept. of Diagnostic and Interventional Radiology, Univ. Ulm (Germany)); Roehrer, Stefan; Kapapa, Thomas (Dept. of Neurosurgery, Univ. Ulm (Germany))

    2011-09-15

    Background: Anatomical variants of the aortic arch and its branching patterns often appear as an incidental finding during routine computed tomography (CT) scanning. These variations can be of relevance when performing angiography or endovascular interventions and may cause symptoms such as dysphagia. Purpose: To analyze common anatomical variations found within the arteries originating from the aortic arch in patients using contrast CT imaging techniques. Material and Methods: A total of 2033 contrast CT scans were analyzed. To obtain a truly representative sample, cases were chosen from different hospital departments without previous knowledge of the patient history. Results: The total percentage of variations within the analyzed patients was 13.3%. In 8.0% a truncus bicaroticus was found. 4.2% of the patients showed a left vertebral artery originating directly from the aortic arch, mostly proximal, and in 1 case distal to the left subclavian artery. In 1.0% we found an aberrant right subclavian artery. We also found a single case of a right descending aortic arch. Conclusion: Variations of the aortic arch and its branching are frequently found, mostly as an incidental finding during routine diagnostic scanning. A contrast-enhanced CT scan is a good method with which to study the aortic arch and its associated branching pattern

  15. Comparison the effect of lidocaine gel and inhalation of lavender aromatherapy on pain score of arteriovenous fistula puncture in hemodialysis patients

    OpenAIRE

    Abbaszadeh

    2015-01-01

    Introduction: patients undergoing hemodialysis repetitively experience pain and anxiety related to arterivenous fistula (AVF) punctures. Using of appropriate methods of pain relief in these patients is very important. The purpose of this study was to compare the effect of lidocaine gel and inhalation of lavender aromatherapy on pain intensity of arterivenous fistula puncture in hemodialysis patients. Methods: In this before and after clinical trial study, 40 hemodialysis patients were sele...

  16. Evaluation of the effects of electron-beam irradiation on the puncture resistance by Lasioderma serricorne in flexible packaging of granola

    International Nuclear Information System (INIS)

    Oliveira, Vitor M.; Alves, Juliana N.; Nogueira, Beatriz R.; Moura, Esperidiana A.B.; Ortiz, Angel V.; Potenza, Marcos R.

    2009-01-01

    Lasioderma serricorne is a beetle that infests stored and industrialized dry foods such as cereal bars, granola, flour and pasta, amongst others, depreciating the products and causing economic losses. It is therefore critical for these products a packaging that presents, in addition to good mechanical, barrier and machinability properties, a good resistance to puncture by insects, in order to prevent the contact and spread of pests in the packaged food. This study evaluates the changes on mechanical properties and puncture resistance by L. serricorne in BOPP/PP structure, used commercially as granola packaging after electron-beam irradiation. The irradiations were performed using a 1.5 MeV electron beam accelerator, dose rate of 11.22 kGy/s, at room temperature in presence of air, doses up to 120 kGy. After irradiation the BOPP/PP samples were subjected to tests of puncture resistance by L. serricorne, tensile strength, friction coefficient, penetration and seal strength. Results showed decreases in the original mechanical properties of the structure according to the radiation doses applied and effective resistance against punctures by L. serricorne (p<0.05). The results indicate that the irradiated and non-irradiated BOPP/PP structure, in the conditions studied in this work, is resistant against L. serricorne, however the decreases observed in the mechanical properties of the irradiated structure may turn it inappropriate for packaging granola. (author)

  17. The CSF and arterial to internal jugular venous hormonal differences during exercise in humans

    DEFF Research Database (Denmark)

    Dalsgaard, Mads K; Ott, Peter; Dela, Flemming

    2004-01-01

    the brain (a-v diff) of hormones that could influence its carbohydrate uptake (n= 9). In addition, neuroendocrine activity and a potential uptake of hormones via the cerebrospinal fluid (CSF) were assessed by lumbar puncture postexercise and at rest (n= 6). Exercise increased the arterial concentration...... of noradrenaline and adrenaline, but there was no cerebral uptake. However, following exercise CSF noradrenaline was 1.4 (0.73-5.5) nmol l(-1), and higher than at rest, 0.3 (0.19-1.84) nmol l(-1) (P ...)(+) and its a-v diff, which increased from 1 (-12 to 5) to 17 (5-41) micromol l(-1) (P CSF NH(4)(+) was reduced to 7 (0-10) versus 11 (7-16) micromol l(-1) (P

  18. The CSF and arterial to internal jugular venous hormonal differences during exercise in humans

    DEFF Research Database (Denmark)

    Dalsgaard, M.K.; Ott, P.; Dela, F.

    2004-01-01

    Strenuous exercise increases the cerebral uptake of carbohydrate out of proportion to that of oxygen, but it is unknown whether such enhanced carbohydrate uptake is influenced by the marked endocrine response to exercise. During exhaustive exercise this study evaluated the a-v differences across...... the brain (a-v diff) of hormones that could influence its carbohydrate uptake (n= 9). In addition, neuroendocrine activity and a potential uptake of hormones via the cerebrospinal fluid (CSF) were assessed by lumbar puncture postexercise and at rest (n= 6). Exercise increased the arterial concentration......)(+) and its a-v diff, which increased from 1 (-12 to 5) to 17 (5-41) micromol l(-1) (P brain of interleukin (IL)-6, tumour necrosis factor (TNF-alpha), heatshock...

  19. Technical measurement of small fission gas inventory in fuel rod with laser puncturing system

    International Nuclear Information System (INIS)

    Kim, Hee Moon; Kim, Sung Ryul; Lee, Byoung Oon; Yang, Yong Sik; Baek, Sang Ryul; Song, Ung Sup

    2012-01-01

    The fission gas release cause degradation of fuel rod. It influences fuel temperature and internal pressure due to low thermal conductivity. Therefore, fission gas released to internal void of fuel rod must be measured with burnup. To measure amount of fission gas, fuel rod must be punctured by a steel needle in a closed chamber. Ideal gas law(PV=nRT) is applied to obtain atomic concentration(mole). Steel needle type is good for large amount of fission gas such as commercial spent fuel rod. But, some cases with small fuel rig in research reactor for R/D program are not available to use needle type because of large chamber volume. The laser puncturing technique was developed to solve measurement of small amount of fission gas. This system was very rare equipment in other countries. Fine pressure gage and strong vacuum system were installed, and the chamber volume was reduced at least. Fiber laser was used for easy operation

  20. Clinical observation of Ahmed glaucoma valve implantation for refractory glaucoma by directly puncturing the sclerotic tunnel

    Directory of Open Access Journals (Sweden)

    Zhi-Ke Xu

    2015-02-01

    Full Text Available AIM: To observe the clinic effects and complication of Ahmed glaucoma valve(AGVimplantation in refractory glaucoma by using the 23G syringe needle direct puncture the sclerotic tunnel.METHODS: Forty-four cases(44 eyesof refractory glaucoma underwent AGV implantation by useing the 23G syringe needle direct puncture the sclerotic tunnel. The intraocular pressure(IOP, visual acuity, and complication of post-operation were contrasted with those of pre-operation. RESULTS:The success rate was 84.1%, the mean preoperative IOP in research group was 52.1±10.1mmHg, and the last follow up mean IOP was 15.6±6.9mmHg. Compared with the preoperative visual acuity, 11 eyes increased, 27 eyes had no changes and 6 eyes decreased. The main post-operative complications included shallow anterior chamber(4 eyes, choroidal detachment(3 eyes, drainage tube shift(1 eye, hyphema(6 eyes, drainage tube blockage(1 eye, expulsive choroidal hemorrhage(1 eye, and fiber wrap of drainage tray(5 eyes.CONCLUSION: AGV implantation by direct puncture the sclerotic tunnel is feasible and easy. It avoids of making sclerotic petal and the xenogenic sclera transplanting, simplified the operation technique, prevent the leakage of around tube. The shallow anterior chamber rate is lower. It is an effective procedure for refractory glaucoma.