WorldWideScience

Sample records for study assessing standardized

  1. Basic Laparoscopic Skills Assessment Study: Validation and Standard Setting among Canadian Urology Trainees.

    Science.gov (United States)

    Lee, Jason Y; Andonian, Sero; Pace, Kenneth T; Grober, Ethan

    2017-06-01

    As urology training programs move to a competency based medical education model, iterative assessments with objective standards will be required. To develop a valid set of technical skills standards we initiated a national skills assessment study focusing initially on laparoscopic skills. Between February 2014 and March 2016 the basic laparoscopic skill of Canadian urology trainees and attending urologists was assessed using 4 standardized tasks from the AUA (American Urological Association) BLUS (Basic Laparoscopic Urological Surgery) curriculum, including peg transfer, pattern cutting, suturing and knot tying, and vascular clip applying. All performances were video recorded and assessed using 3 methods, including time and error based scoring, expert global rating scores and C-SATS (Crowd-Sourced Assessments of Technical Skill Global Rating Scale), a novel, crowd sourced assessment platform. Different methods of standard setting were used to develop pass-fail cut points. Six attending urologists and 99 trainees completed testing. Reported laparoscopic experience and training level correlated with performance (p standard setting methods to define pass-fail cut points for all 4 AUA BLUS tasks. The 4 AUA BLUS tasks demonstrated good construct validity evidence for use in assessing basic laparoscopic skill. Performance scores using the novel C-SATS platform correlated well with traditional time-consuming methods of assessment. Various standard setting methods were used to develop pass-fail cut points for educators to use when making formative and summative assessments of basic laparoscopic skill. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. EMBEDding the CEFR in Academic Writing Assessment : A case study in training and standardization

    NARCIS (Netherlands)

    Haines, Kevin; Lowie, Wander; Jansma, Petra; Schmidt, Nicole

    2013-01-01

    The CEFR is increasingly being used as the framework of choice for the assessment of language proficiency at universities across Europe. However, to attain consistent assessment, familiarization and standardization are essential. In this paper we report a case study of embedding a standardization

  3. State Standards and State Assessment Systems: A Guide to Alignment. Series on Standards and Assessments.

    Science.gov (United States)

    La Marca, Paul M.; Redfield, Doris; Winter, Phoebe C.

    Alignment of content standards, performance standards, and assessments is crucial. This guide contains information to assist states and districts in aligning their assessment systems to their content and performance standards. It includes a review of current literature, both published and fugitive. The research is woven together with a few basic…

  4. Effect of standardized training on the reliability of the Cochrane risk of bias assessment tool: a study protocol.

    Science.gov (United States)

    da Costa, Bruno R; Resta, Nina M; Beckett, Brooke; Israel-Stahre, Nicholas; Diaz, Alison; Johnston, Bradley C; Egger, Matthias; Jüni, Peter; Armijo-Olivo, Susan

    2014-12-13

    The Cochrane risk of bias (RoB) tool has been widely embraced by the systematic review community, but several studies have reported that its reliability is low. We aim to investigate whether training of raters, including objective and standardized instructions on how to assess risk of bias, can improve the reliability of this tool. We describe the methods that will be used in this investigation and present an intensive standardized training package for risk of bias assessment that could be used by contributors to the Cochrane Collaboration and other reviewers. This is a pilot study. We will first perform a systematic literature review to identify randomized clinical trials (RCTs) that will be used for risk of bias assessment. Using the identified RCTs, we will then do a randomized experiment, where raters will be allocated to two different training schemes: minimal training and intensive standardized training. We will calculate the chance-corrected weighted Kappa with 95% confidence intervals to quantify within- and between-group Kappa agreement for each of the domains of the risk of bias tool. To calculate between-group Kappa agreement, we will use risk of bias assessments from pairs of raters after resolution of disagreements. Between-group Kappa agreement will quantify the agreement between the risk of bias assessment of raters in the training groups and the risk of bias assessment of experienced raters. To compare agreement of raters under different training conditions, we will calculate differences between Kappa values with 95% confidence intervals. This study will investigate whether the reliability of the risk of bias tool can be improved by training raters using standardized instructions for risk of bias assessment. One group of inexperienced raters will receive intensive training on risk of bias assessment and the other will receive minimal training. By including a control group with minimal training, we will attempt to mimic what many review authors

  5. Psychological distress and streamlined BreastScreen follow-up assessment versus standard assessment.

    Science.gov (United States)

    Sherman, Kerry A; Winch, Caleb J; Borecky, Natacha; Boyages, John

    2013-11-04

    To establish whether altered protocol characteristics of streamlined StepDown breast assessment clinics heightened or reduced the psychological distress of women in attendance compared with standard assessment. Willingness to attend future screening was also compared between the assessment groups. Observational, prospective study of women attending either a mammogram-only StepDown or a standard breast assessment clinic. Women completed questionnaires on the day of assessment and 1 month later. Women attending StepDown (136 women) or standard assessment clinics (148 women) at a BreastScreen centre between 10 November 2009 and 7 August 2010. Breast cancer worries; positive and negative psychological consequences of assessment (Psychological Consequences Questionnaire); breast cancer-related intrusion and avoidance (Impact of Event Scale); and willingness to attend, and uneasiness about, future screening. At 1-month follow-up, no group differences were evident between those attending standard and StepDown clinics on breast cancer worries (P= 0.44), positive (P= 0.88) and negative (P = 0.65) consequences, intrusion (P = 0.64), and avoidance (P = 0.87). Willingness to return for future mammograms was high, and did not differ between groups (P = 0.16), although higher levels of unease were associated with lessened willingness to rescreen (P = 0.04). There was no evidence that attending streamlined StepDown assessments had different outcomes in terms of distress than attending standard assessment clinics for women with a BreastScreen-detected abnormality. However, unease about attending future screening was generally associated with less willingness to do so in both groups; thus, there is a role for psycho-educational intervention to address these concerns.

  6. Alignment between South African mathematics assessment standards and the TIMSS assessment frameworks

    Directory of Open Access Journals (Sweden)

    Mdutshekelwa Ndlovu

    2012-12-01

    Full Text Available South Africa’s performance in international benchmark tests is a major cause for concern amongst educators and policymakers, raising questions about the effectiveness of the curriculum reform efforts of the democratic era. The purpose of the study reported in this article was to investigate the degree of alignment between the TIMSS 2003 Grade 8 Mathematics assessment frameworks and the Revised National Curriculum Statements (RNCS assessment standards for Grade 8 Mathematics, later revised to become the Curriculum and Assessment Policy Statements (CAPS. Such an investigation could help to partly shed light on why South African learners do not perform well and point out discrepancies that need to be attended to. The methodology of document analysis was adopted for the study, with the RNCS and the TIMSS 2003 Grade 8 Mathematics frameworks forming the principal documents. Porter’s moderately complex index of alignment was adopted for its simplicity. The computed index of 0.751 for the alignment between the RNCS assessment standards and the TIMSS assessment objectives was found to be significantly statistically low, at the alpha level of 0.05, according to Fulmer’s critical values for 20 cells and 90 or 120 standard points. The study suggests that inadequate attention has been paid to the alignment of the South African mathematics curriculum to the successive TIMSS assessment frameworks in terms of the cognitive level descriptions. The study recommends that participation in TIMSS should rigorously and critically inform ongoing curriculum reform efforts.

  7. Assessing children’s competence to consent in research by a standardized tool: a validity study

    Science.gov (United States)

    2012-01-01

    Background Currently over 50% of drugs prescribed to children have not been evaluated properly for use in their age group. One key reason why children have been excluded from clinical trials is that they are not considered able to exercise meaningful autonomy over the decision to participate. Dutch law states that competence to consent can be presumed present at the age of 12 and above; however, in pediatric practice children’s competence is not that clearly presented and the transition from assent to active consent is gradual. A gold standard for competence assessment in children does not exist. In this article we describe a study protocol on the development of a standardized tool for assessing competence to consent in research in children and adolescents. Methods/design In this study we modified the MacCAT-CR, the best evaluated competence assessment tool for adults, for use in children and adolescents. We will administer the tool prospectively to a cohort of pediatric patients from 6 to18 years during the selection stages of ongoing clinical trials. The outcomes of the MacCAT-CR interviews will be compared to a reference standard, established by the judgments of clinical investigators, and an expert panel consisting of child psychiatrists, child psychologists and medical ethicists. The reliability, criterion-related validity and reproducibility of the tool will be determined. As MacCAT-CR is a multi-item scale consisting of 13 items, power was justified at 130–190 subjects, providing a minimum of 10–15 observations per item. MacCAT-CR outcomes will be correlated with age, life experience, IQ, ethnicity, socio-economic status and competence judgment of the parent(s). It is anticipated that 160 participants will be recruited over 2 years to complete enrollment. Discussion A validity study on an assessment tool of competence to consent is strongly needed in research practice, particularly in the child and adolescent population. In this study we will establish

  8. Assessing children’s competence to consent in research by a standardized tool: a validity study

    Directory of Open Access Journals (Sweden)

    Hein Irma M

    2012-09-01

    Full Text Available Abstract Background Currently over 50% of drugs prescribed to children have not been evaluated properly for use in their age group. One key reason why children have been excluded from clinical trials is that they are not considered able to exercise meaningful autonomy over the decision to participate. Dutch law states that competence to consent can be presumed present at the age of 12 and above; however, in pediatric practice children’s competence is not that clearly presented and the transition from assent to active consent is gradual. A gold standard for competence assessment in children does not exist. In this article we describe a study protocol on the development of a standardized tool for assessing competence to consent in research in children and adolescents. Methods/design In this study we modified the MacCAT-CR, the best evaluated competence assessment tool for adults, for use in children and adolescents. We will administer the tool prospectively to a cohort of pediatric patients from 6 to18 years during the selection stages of ongoing clinical trials. The outcomes of the MacCAT-CR interviews will be compared to a reference standard, established by the judgments of clinical investigators, and an expert panel consisting of child psychiatrists, child psychologists and medical ethicists. The reliability, criterion-related validity and reproducibility of the tool will be determined. As MacCAT-CR is a multi-item scale consisting of 13 items, power was justified at 130–190 subjects, providing a minimum of 10–15 observations per item. MacCAT-CR outcomes will be correlated with age, life experience, IQ, ethnicity, socio-economic status and competence judgment of the parent(s. It is anticipated that 160 participants will be recruited over 2 years to complete enrollment. Discussion A validity study on an assessment tool of competence to consent is strongly needed in research practice, particularly in the child and adolescent population. In

  9. Assessment of Safety Standards for Automotive Electronic Control Systems

    Science.gov (United States)

    2016-06-01

    This report summarizes the results of a study that assessed and compared six industry and government safety standards relevant to the safety and reliability of automotive electronic control systems. These standards include ISO 26262 (Road Vehicles - ...

  10. A Pilot Study on Developing a Standardized and Sensitive School Violence Risk Assessment with Manual Annotation.

    Science.gov (United States)

    Barzman, Drew H; Ni, Yizhao; Griffey, Marcus; Patel, Bianca; Warren, Ashaki; Latessa, Edward; Sorter, Michael

    2017-09-01

    School violence has increased over the past decade and innovative, sensitive, and standardized approaches to assess school violence risk are needed. In our current feasibility study, we initialized a standardized, sensitive, and rapid school violence risk approach with manual annotation. Manual annotation is the process of analyzing a student's transcribed interview to extract relevant information (e.g., key words) to school violence risk levels that are associated with students' behaviors, attitudes, feelings, use of technology (social media and video games), and other activities. In this feasibility study, we first implemented school violence risk assessments to evaluate risk levels by interviewing the student and parent separately at the school or the hospital to complete our novel school safety scales. We completed 25 risk assessments, resulting in 25 transcribed interviews of 12-18 year olds from 15 schools in Ohio and Kentucky. We then analyzed structured professional judgments, language, and patterns associated with school violence risk levels by using manual annotation and statistical methodology. To analyze the student interviews, we initiated the development of an annotation guideline to extract key information that is associated with students' behaviors, attitudes, feelings, use of technology and other activities. Statistical analysis was applied to associate the significant categories with students' risk levels to identify key factors which will help with developing action steps to reduce risk. In a future study, we plan to recruit more subjects in order to fully develop the manual annotation which will result in a more standardized and sensitive approach to school violence assessments.

  11. An exploratory study of the influence of national and state standards on middle school science teachers' classroom assessment practices

    Science.gov (United States)

    McWaters, Kathy Jean

    2001-07-01

    Classroom assessment practices of middle school science teachers were identified and the influence of national and state science standards on these practices was examined. In Phase I of this study a mail questionnaire was sent to 450 middle school (grades 5,6,7 and 8) science teachers in 17 parishes in Louisiana to obtain information about their classroom assessment practices. In Phase II, nine middle school teachers in eight departmentalized classrooms, two classes at each grade, participated in a qualitative study. Data were collected through questionnaires, classroom observations, interviews and document analysis. Data analysis revealed three major categories of classroom assessment targets: (a) student achievement, (b) student attitudes and, (c) student products. Results indicated that most teachers are using different assessment methods when assessing different achievement targets, as recommended by science reform documents. It was also determined that many teachers are using appropriate methods to assess student learning. While teachers reported that students spend an inordinate amount of time engaged in assessment activities, classroom observations suggested that the activities were not always written tests or graded activities. Another key finding is that there is a disconnect between the quality of teaching and the quality of assessment. Teachers who teach the material recommended by science reform documents and use recommended instructional strategies were observed to stop teaching and engage students in a "test rehearsal" geared towards rote memorization of factual information. Data suggest that the national and state science content standards are influencing the content and the format of teacher-made tests. Teachers' reported using the standards during assessment construction or selection in a wide variety of ways. The most direct use of the standards reported was to select content, format and cognitive level for test items. A more circumspect approach

  12. Effect of standardized training on the reliability of the Cochrane risk of bias assessment tool: a prospective study.

    Science.gov (United States)

    da Costa, Bruno R; Beckett, Brooke; Diaz, Alison; Resta, Nina M; Johnston, Bradley C; Egger, Matthias; Jüni, Peter; Armijo-Olivo, Susan

    2017-03-03

    The Cochrane risk of bias tool is commonly criticized for having a low reliability. We aimed to investigate whether training of raters, with objective and standardized instructions on how to assess risk of bias, can improve the reliability of the Cochrane risk of bias tool. In this pilot study, four raters inexperienced in risk of bias assessment were randomly allocated to minimal or intensive standardized training for risk of bias assessment of randomized trials of physical therapy treatments for patients with knee osteoarthritis pain. Two raters were experienced risk of bias assessors who served as reference. The primary outcome of our study was between-group reliability, defined as the agreement of the risk of bias assessments of inexperienced raters with the reference assessments of experienced raters. Consensus-based assessments were used for this purpose. The secondary outcome was within-group reliability, defined as the agreement of assessments within pairs of inexperienced raters. We calculated the chance-corrected weighted Kappa to quantify agreement within and between groups of raters for each of the domains of the risk of bias tool. A total of 56 trials were included in our analysis. The Kappa for the agreement of inexperienced raters with reference across items of the risk of bias tool ranged from 0.10 to 0.81 for the minimal training group and from 0.41 to 0.90 for the standardized training group. The Kappa values for the agreement within pairs of inexperienced raters across the items of the risk of bias tool ranged from 0 to 0.38 for the minimal training group and from 0.93 to 1 for the standardized training group. Between-group differences in Kappa for the agreement of inexperienced raters with reference always favored the standardized training group and was most pronounced for incomplete outcome data (difference in Kappa 0.52, p training on risk of bias assessment may significantly improve the reliability of the Cochrane risk of bias tool.

  13. STANDARDIZING QUALITY ASSESSMENT OF FUSED REMOTELY SENSED IMAGES

    Directory of Open Access Journals (Sweden)

    C. Pohl

    2017-09-01

    Full Text Available The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  14. Standardizing Quality Assessment of Fused Remotely Sensed Images

    Science.gov (United States)

    Pohl, C.; Moellmann, J.; Fries, K.

    2017-09-01

    The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment) in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS) to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR) and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  15. Shifting Gears: Standards, Assessments, Curriculum, & Instruction.

    Science.gov (United States)

    Dougherty, Eleanor

    This book is designed to help educators move from a system that measures students against students to one that values mastery of central concepts and skills, striving for proficiency in publicly acknowledged standards of academic performance. It aims to connect the operative parts of standards-based education (standards, assessment, curriculum,…

  16. Study on Design and Implementation of JAVA Programming Procedural Assessment Standard

    Science.gov (United States)

    Tingting, Xu; Hua, Ma; Xiujuan, Wang; Jing, Wang

    2015-01-01

    The traditional JAVA course examination is just a list of questions from which we cannot know students' skills of programming. According to the eight abilities in curriculum objectives, we designed an assessment standard of JAVA programming course that is based on employment orientation and apply it to practical teaching to check the teaching…

  17. Assessing the Effects of Corporate Social Responsibility Standards in Global Value Chains

    DEFF Research Database (Denmark)

    Lund-Thomsen, Peter

    This paper considers the issue of corporate social responsibility (CSR) standard impact assessment in global value chains. CSR standards have proliferated in recent years, and several studies have attempted to assess their effects on local producers, workers, and the environment in developing...... countries. However, much less attention has been paid to the “dark side” of impact assessment – the ethical and political dilemmas that arise in the process of carrying out impact studies. This paper addresses this gap in literature, arguing that impact assessments of CSR standards may do more harm than...... good to the intended beneficiaries - developing country firms, farmers, workers, and communities - unless these ethical and political dilemmas are given serious consideration....

  18. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    Science.gov (United States)

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  19. The Common Core State Standards: An Opportunity to Enhance Formative Assessment in History/Social Studies Classrooms

    Science.gov (United States)

    Ateh, Comfort M.; Wyngowski, Aaron J.

    2015-01-01

    This article discusses the opportunity that the Common Core State Standards (CCSS) present for enhancing formative assessment (FA) in history and social studies classrooms. There is evidence that FA can enhance learning for students if implemented well. Unfortunately, teachers continue to be challenged in implementing FA in their classrooms. We…

  20. MR imaging of the articular cartilage of the knee with arthroscopy as gold standard: assessment of methodological quality of clinical studies

    International Nuclear Information System (INIS)

    Duchateau, Florence; Berg, Bruno C. vande

    2002-01-01

    The purpose of this study was to assess the methodological quality of articles addressing the value of MR imaging of the knee cartilage with arthroscopy as a standard. Relevant papers were selected after Medline review (MEDLINE database search including the terms ''cartilage'' ''knee'', ''MR'' and ''arthroscopy''). Two observers reviewed independently 29 selected articles to determine how each study had met 15 individual standards that had been previously developed to assess the methodological quality of clinical investigations. The following criteria were met in variable percentage of articles including adequate definition of purpose (100%), statistical analysis (90%), avoidance of verification bias (86%), patient population description (83%), reference standard (79%), review bias (79%), study design (66%), inclusion criteria (41%) and method of analysis (41.5%), avoidance of diagnostic-review bias (24%), exclusion criteria (21%), indeterminate examination results (17%), analysis criteria (14%), interobserver reliability (14%) and intraobserver reliability (7%). The assessment of the methodological quality of clinical investigations addressing the value of MR imaging in the evaluation of the articular cartilage of the knee with arthroscopy as the standard of reference demonstrated that several standards were rarely met in the literature. Efforts should be made to rely on clearly defined lesion criteria and to determine reliability of the observations. (orig.)

  1. Newly graduated doctors' competence in managing cardiopulmonary arrests assessed using a standardized Advanced Life Support (ALS) assessment

    DEFF Research Database (Denmark)

    Jensen, Morten Lind; Hesselfeldt, Rasmus; Rasmussen, Maria Birkvad

    2008-01-01

    Aim of the study: Several studies using a variety of assessment approaches have demonstrated that young doctors possess insufficient resuscitation competence. The aims of this study were to assess newly graduated doctors’ resuscitation competence against an internationally recognised standard and...

  2. Standards, Assessments & Opting Out, Spring 2015

    Science.gov (United States)

    Advance Illinois, 2015

    2015-01-01

    In the spring, Illinois students will take new state assessments that reflect the rigor and relevance of the new Illinois Learning Standards. But some classmates will sit out and join the pushback against standardized testing. Opt-out advocates raise concerns about over-testing, and the resulting toll on students as well as the impact on classroom…

  3. The Rest of the Story: A Qualitative Study of Complementing Standardized Assessment Data with Informal Interviews with Older Patients and Families.

    Science.gov (United States)

    Lafortune, Claire; Elliott, Jacobi; Egan, Mary Y; Stolee, Paul

    2017-04-01

    While standardized health assessments capture valuable information on patients' demographic and diagnostic characteristics, health conditions, and physical and mental functioning, they may not capture information of most relevance to individual patients and their families. Given that patients and their informal caregivers are the experts on that patient's unique context, it is important to ensure they are able to convey all relevant personal information to formal healthcare providers so that high-quality, patient-centered care may be delivered. This study aims to identify information that older patients and families consider important but that might not be included in standardized assessments. Transcripts were analyzed from 29 interviews relating to eight patients with hip fractures from three sites (large urban, smaller urban, rural) in two provinces in Canada. These interviews were conducted as part of a larger ethnographic study. Each transcript was analyzed by two researchers using content analysis. Results were reviewed in two focus group interviews with older adults and family caregivers. Identified themes were compared with items from two standardized assessments used in healthcare settings. Three broad themes emerged from the qualitative analysis that were not covered in the standardized assessments: informal caregiver and family considerations, insider healthcare knowledge, and patients' healthcare attitudes and experiences. The importance of these themes was confirmed through focus group interviews. Focus group participants also emphasized the importance of conducting assessments in a patient-centered way and the importance of open-ended questions. A less structured interview approach may yield information that would otherwise be missed in standardized assessments. Combining both sources could yield better-informed healthcare planning and quality-improvement efforts.

  4. Performance Standards': Utility for Different Uses of Assessments

    Directory of Open Access Journals (Sweden)

    Robert L. Linn

    2003-09-01

    Full Text Available Performance standards are arguably one of the most controversial topics in educational measurement. There are uses of assessments such as licensure and certification where performance standards are essential. There are many other uses, however, where performance standards have been mandated or become the preferred method of reporting assessment results where the standards are not essential to the use. Distinctions between essential and nonessential uses of performance standards are discussed. It is argued that the insistence on reporting in terms of performance standards in situations where they are not essential has been more harmful than helpful. Variability in the definitions of proficient academic achievement by states for purposes of the No Child Left Behind Act of 2001 is discussed and it is argued that the variability is so great that characterizing achievement is meaningless. Illustrations of the great uncertainty in standards are provided.

  5. Impact assessment of commodity standards

    NARCIS (Netherlands)

    Ruben, Ruerd

    2017-01-01

    Voluntary commodity standards are widely used to enhance the performance of tropical agro-food chains and to support the welfare and sustainability of smallholder farmers. Different methods and approaches are used to assess the effectiveness and impact of these certification schemes at

  6. Risk assessment of manual material handling activities (case study: PT BRS Standard Industry)

    Science.gov (United States)

    Deviani; Triyanti, V.

    2017-12-01

    The process of moving material manually has the potential for injury to workers. The risk of injury will increase if we do not pay attention to the working conditions. The purpose of this study is to assess and analyze the injury risk level in manual handling material activity, as well as to improve the condition. The observed manual material handling activities is pole lifting and goods loading. These activities were analyzed using Job Strain Index method, Rapid Entire Body Assessment, and Chaffin’s 2D Planar Static Model. The results show that most workers who perform almost all activities have a high level of risk level with the score of JSI and REBA exceeds 9 points. For some activities, the estimated compression forces in the lumbar area also exceed the standard limits of 3400 N. Concerning this condition, several suggestions for improvement were made, improving the composition of packing, improving body posture, and making guideline posters.

  7. Comparing Panelists' Understanding of Standard Setting across Multiple Levels of an Alternate Science Assessment

    Science.gov (United States)

    Hansen, Mary A.; Lyon, Steven R.; Heh, Peter; Zigmond, Naomi

    2013-01-01

    Large-scale assessment programs, including alternate assessments based on alternate achievement standards (AA-AAS), must provide evidence of technical quality and validity. This study provides information about the technical quality of one AA-AAS by evaluating the standard setting for the science component. The assessment was designed to have…

  8. Cross-cultural validity of standardized motor development screening and assessment tools: a systematic review.

    Science.gov (United States)

    Mendonça, Bianca; Sargent, Barbara; Fetters, Linda

    2016-12-01

    To investigate whether standardized motor development screening and assessment tools that are used to evaluate motor abilities of children aged 0 to 2 years are valid in cultures other than those in which the normative sample was established. This was a systematic review in which six databases were searched. Studies were selected based on inclusion/exclusion criteria and appraised for evidence level and quality. Study variables were extracted. Twenty-three studies representing six motor development screening and assessment tools in 16 cultural contexts met the inclusion criteria: Alberta Infant Motor Scale (n=7), Ages and Stages Questionnaire, 3rd edition (n=2), Bayley Scales of Infant and Toddler Development, 3rd edition (n=8), Denver Developmental Screening Test, 2nd edition (n=4), Harris Infant Neuromotor Test (n=1), and Peabody Developmental Motor Scales, 2nd edition (n=1). Thirteen studies found significant differences between the cultural context and normative sample. Two studies established reliability and/or validity of standardized motor development assessments in high-risk infants from different cultural contexts. Five studies established new population norms. Eight studies described the cross-cultural adaptation of a standardized motor development assessment. Standardized motor development assessments have limited validity in cultures other than that in which the normative sample was established. Their use can result in under- or over-referral for services. © 2016 Mac Keith Press.

  9. Collaborative study to assess the suitability of a candidate International Standard for yellow fever vaccine.

    Science.gov (United States)

    Ferguson, Morag; Heath, Alan

    2004-12-01

    Yellow fever vaccines are routinely assayed by plaque assay. However, the results of these assays are then converted into mouse LD(50) using correlations/conversion factors which, in many cases, were established many years ago. The minimum required potency in WHO Recommendations is 10(3) LD(50)/dose. Thirteen participants from 8 countries participated in a collaborative study whose aim was to assess the suitability of two candidate preparations to serve as an International Standard for yellow fever vaccine. In addition, the study investigated the relationship between the mouse LD(50) test and plaque forming units with a view to updating the WHO recommendations. Plaque assays were more reproducible than mouse assays, as expected. Differences in sensitivities of plaque assays were observed between laboratories but these differences appear to be consistent within a laboratory for all samples and the expression of potency relative to the candidate standard vaccine improved the reproducibility of assays between laboratories. However, the use of potencies had little effect on the between laboratory variability in mouse LD(50) assays. There appears to be a consistent relationship between overall mean LD(50) and plaques titre for all study preparations other than sample E. The slope of the correlation curve is >1 and it would appear that 10(3) LD(50) is approximately equivalent to 10(4) plaque forming units (PFU), based on the overall means of all laboratory results. The First International Standard for yellow fever vaccine, NIBSC Code 99/616, has been established as the First International Standard for yellow fever vaccine by the Expert Committee of Biological Standards of the World Health Organisation. The International Standard has been arbitrarily assigned a potency of 10(4.5) International Units (IU) per ampoule. Manufacturers and National Control Laboratories are including the First International Standard for yellow fever vaccine in routine assays so that the minimum

  10. DIFFERENCES IN MANAGER ASSESSMENTS OF ISO 14000 STANDARD IMPLEMENTATION IN TURKEY

    Directory of Open Access Journals (Sweden)

    Sıtkı Gözlü

    2005-12-01

    Full Text Available This study reports the results of a survey about the improvements achieved as result of ISO 14000 Environmental Management System (EMS standard implementation and the differences of improvements with respect to firm characteristics. A survey has been conducted in order to explain the improvements related to environmental management process and overall firm performance. The survey involved sixty-six enterprises implementing ISO 14000 EMS standard in Turkey. In order to assess improvements obtained from ISO 14000 EMS implementation, statements related to environmental management process and overall firm performance indicators have been prepared. The statements in this study are relevant to previous research. A factor analysis was employed to determine the factors of the variables explaining improvements. Nine factors have been identified related to achieved improvements, such as establishment of pro-active environmental management system, effectiveness in resource utilization, effectiveness of process control, relationships with industry and government, meeting expectations of stakeholders, demonstration of social responsibility, profitability, productivity, and competitiveness. Then, a T- test was conducted to determine the differences of managers’ assessments with respect to certain firm characteristics. The findings have shown that there are differences in the assessments of improvements achieved as a result of ISO 14000 EMS standard implementation with respect to sales volume, foreign-capital possession, and ISO 14000 EMS standard implementation. On the other hand, industrial sector, age of establishment, and export orientation are not statistically significant for the differences in the assessments of improvements.

  11. Validity, Reliability and Standardization Study of the Language Assessment Test for Aphasia

    Directory of Open Access Journals (Sweden)

    Bülent Toğram

    2012-09-01

    Full Text Available OBJECTIVE: Aphasia assessment is the first step towards a well- founded language therapy. Language tests need to consider cultural as well as typological linguistic aspects of a given language. This study was designed to determine the standardization, validity and reliability of Language Assessment Test for Aphasia, which consists of eight subtests including spontaneous speech and language, auditory comprehension, repetition, naming, reading, grammar, speech acts, and writing. METHODS: The test was administered to 282 healthy participants and 92 aphasic participants in age, education and gender matched groups. The validity study of the test was investigated with analysis of content, structure and criterion-related validity. For reliability of the test, the analysis of internal consistency, stability and equivalence reliability was conducted. The influence of variables on healhty participants’ sub-test scores, test score and language score was examined. According to significant differences, norms and cut-off scores based on language score were determined. RESULTS: The group with aphasia performed highly lower than healthy participants on subtest, test and language scores. The test scores of healthy group were mostly affected by age and educational level but not affected by gender. According to significant differences, age and educational level for both groups were determined. Considering age and educational levels, the reference values for the cut-off scores were presented. CONCLUSION: The test was found to be a highly reliable and valid aphasia test for Turkish- speaking aphasic patients either in Turkey or other Turkish communities around the world

  12. A comparative study on assessment procedures and metric properties of two scoring systems of the Coma Recovery Scale-Revised items: standard and modified scores.

    Science.gov (United States)

    Sattin, Davide; Lovaglio, Piergiorgio; Brenna, Greta; Covelli, Venusia; Rossi Sebastiano, Davide; Duran, Dunja; Minati, Ludovico; Giovannetti, Ambra Mara; Rosazza, Cristina; Bersano, Anna; Nigri, Anna; Ferraro, Stefania; Leonardi, Matilde

    2017-09-01

    The study compared the metric characteristics (discriminant capacity and factorial structure) of two different methods for scoring the items of the Coma Recovery Scale-Revised and it analysed scale scores collected using the standard assessment procedure and a new proposed method. Cross sectional design/methodological study. Inpatient, neurological unit. A total of 153 patients with disorders of consciousness were consecutively enrolled between 2011 and 2013. All patients were assessed with the Coma Recovery Scale-Revised using standard (rater 1) and inverted (rater 2) procedures. Coma Recovery Scale-Revised score, number of cognitive and reflex behaviours and diagnosis. Regarding patient assessment, rater 1 using standard and rater 2 using inverted procedures obtained the same best scores for each subscale of the Coma Recovery Scale-Revised for all patients, so no clinical (and statistical) difference was found between the two procedures. In 11 patients (7.7%), rater 2 noted that some Coma Recovery Scale-Revised codified behavioural responses were not found during assessment, although higher response categories were present. A total of 51 (36%) patients presented the same Coma Recovery Scale-Revised scores of 7 or 8 using a standard score, whereas no overlap was found using the modified score. Unidimensionality was confirmed for both score systems. The Coma Recovery Scale Modified Score showed a higher discriminant capacity than the standard score and a monofactorial structure was also supported. The inverted assessment procedure could be a useful evaluation method for the assessment of patients with disorder of consciousness diagnosis.

  13. Planning the Unplanned Experiment: Towards Assessing the Efficacy of Standards for Safety-Critical Software

    Science.gov (United States)

    Graydon, Patrick J.; Holloway, C. M.

    2015-01-01

    Safe use of software in safety-critical applications requires well-founded means of determining whether software is fit for such use. While software in industries such as aviation has a good safety record, little is known about whether standards for software in safety-critical applications 'work' (or even what that means). It is often (implicitly) argued that software is fit for safety-critical use because it conforms to an appropriate standard. Without knowing whether a standard works, such reliance is an experiment; without carefully collecting assessment data, that experiment is unplanned. To help plan the experiment, we organized a workshop to develop practical ideas for assessing software safety standards. In this paper, we relate and elaborate on the workshop discussion, which revealed subtle but important study design considerations and practical barriers to collecting appropriate historical data and recruiting appropriate experimental subjects. We discuss assessing standards as written and as applied, several candidate definitions for what it means for a standard to 'work,' and key assessment strategies and study techniques and the pros and cons of each. Finally, we conclude with thoughts about the kinds of research that will be required and how academia, industry, and regulators might collaborate to overcome the noted barriers.

  14. Health impact assessment in the United States: Has practice followed standards?

    International Nuclear Information System (INIS)

    Schuchter, Joseph; Bhatia, Rajiv; Corburn, Jason; Seto, Edmund

    2014-01-01

    As an emerging practice, Health Impact Assessment is heterogeneous in purpose, form, and scope and applied in a wide range of decision contexts. This heterogeneity challenges efforts to evaluate the quality and impact of practice. We examined whether information in completed HIA reports reflected objectively-evaluable criteria proposed by the North American HIA Practice Standards Working Group in 2009. From publically-available reports of HIAs conducted in the U.S. and published from 2009 to 2011, we excluded those that were components of, or comment letters on, Environmental Impact Assessments (5) or were demonstration projects or student exercises (8). For the remaining 23 reports, we used practice standards as a template to abstract data on the steps of HIA, including details on the rationale, authorship, funding, decision and decision-makers, participation, pathways and methods, quality of evidence, and recommendations. Most reports described screening, scoping, and assessment processes, but there was substantial variation in the extent of these processes and the degree of stakeholder participation. Community stakeholders participated in screening or scoping in just two-thirds of the HIAs (16). On average, these HIAs analyzed 5.5 determinants related to 10.6 health impacts. Most HIA reports did not include evaluation or monitoring plans. This study identifies issues for field development and improvement. The standards might be adapted to better account for variability in resources, produce fit-for-purpose HIAs, and facilitate innovation guided by the principles. - Highlights: • Our study examined reported HIAs in the U.S. against published practice standards. • Most HIAs used some screening, scoping and assessment elements from the standards. • The extent of these processes and stakeholder participation varied widely. • The average HIA considered multiple health determinants and impacts. • Evaluation or monitoring plans were generally not included in

  15. Health impact assessment in the United States: Has practice followed standards?

    Energy Technology Data Exchange (ETDEWEB)

    Schuchter, Joseph, E-mail: jws@berkeley.edu [University of California, Berkeley, School of Public Health, Department of Environmental Health Sciences, 50 University Hall, Berkeley, CA 94720-7360 (United States); Bhatia, Rajiv [University of California, Berkeley, Institute of Urban and Regional Development (United States); Corburn, Jason [University of California, Berkeley, College of Environmental Design, Department of City and Regional Planning (United States); Seto, Edmund [University of Washington, School of Public Health, Department of Environmental and Occupational Health (United States)

    2014-07-01

    As an emerging practice, Health Impact Assessment is heterogeneous in purpose, form, and scope and applied in a wide range of decision contexts. This heterogeneity challenges efforts to evaluate the quality and impact of practice. We examined whether information in completed HIA reports reflected objectively-evaluable criteria proposed by the North American HIA Practice Standards Working Group in 2009. From publically-available reports of HIAs conducted in the U.S. and published from 2009 to 2011, we excluded those that were components of, or comment letters on, Environmental Impact Assessments (5) or were demonstration projects or student exercises (8). For the remaining 23 reports, we used practice standards as a template to abstract data on the steps of HIA, including details on the rationale, authorship, funding, decision and decision-makers, participation, pathways and methods, quality of evidence, and recommendations. Most reports described screening, scoping, and assessment processes, but there was substantial variation in the extent of these processes and the degree of stakeholder participation. Community stakeholders participated in screening or scoping in just two-thirds of the HIAs (16). On average, these HIAs analyzed 5.5 determinants related to 10.6 health impacts. Most HIA reports did not include evaluation or monitoring plans. This study identifies issues for field development and improvement. The standards might be adapted to better account for variability in resources, produce fit-for-purpose HIAs, and facilitate innovation guided by the principles. - Highlights: • Our study examined reported HIAs in the U.S. against published practice standards. • Most HIAs used some screening, scoping and assessment elements from the standards. • The extent of these processes and stakeholder participation varied widely. • The average HIA considered multiple health determinants and impacts. • Evaluation or monitoring plans were generally not included in

  16. Making Use of the New Student Assessment Standards To Enhance Technological Literacy.

    Science.gov (United States)

    Russell, Jill

    2003-01-01

    Describes the student assessment standards outlined in "Advancing Excellence in Technological Literacy: Student Assessment, Professional Development, and Program Standards," a companion to the "Standards for Technological Literacy." Discusses how the standards apply to everyday teaching practices. (JOW)

  17. Multislice computed tomography: angiographic emulation versus standard assessment for detection of coronary stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk; Hamm, Bernd; Dewey, Marc [Humboldt-Universitaet zu Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin, Chariteplatz 1, P.O. Box 10098, Berlin (Germany); Duebel, Hans-Peter; Baumann, Gert [Charite - Universitaetsmedizin Berlin, Department of Cardiology, Berlin (Germany); Scholze, Juergen [Charite - Universitaetsmedizin Berlin, Charite Outpatient Centre, Berlin (Germany)

    2007-07-15

    The present study investigated angiographic emulation of multislice computed tomography (MSCT) (catheter-like visualization) as an alternative approach of analyzing and visualizing findings in comparison with standard assessment. Thirty patients (120 coronary arteries) were randomly selected from 90 prospectively investigated patients with suspected coronary artery disease who underwent MSCT (16-slice scanner, 0.5 mm collimation, 400 ms rotation time) prior to conventional coronary angiography for comparison of both approaches. Sensitivity and specificity of angiographic emulation [81% (26/32) and 93% (82/88)] were not significantly different from those of standard assessment [88% (28/32) and 99% (87/88)], while the per-case analysis time was significantly shorter for angiographic emulation than for standard assessment (3.4 {+-} 1.5 vs 7.0 {+-} 2.5 min, P < 0.001). Both interventional and referring cardiologists preferred angiographic emulation over standard curved multiplanar reformations of MSCT coronary angiography for illustration, mainly because of improved overall lucidity and depiction of sidebranches (P < 0.001). In conclusion, angiographic emulation of MSCT reduces analysis time, yields a diagnostic accuracy comparable to that of standard assessment, and is preferred by cardiologists for visualization of results. (orig.)

  18. Leading the Transition from the Alternate Assessment Based on Modified Achievement Standards to the General Assessment

    Science.gov (United States)

    Lazarus, Sheryl S.; Rieke, Rebekah

    2013-01-01

    Schools are facing many changes in the ways that teaching, learning, and assessment take place. Most states are moving from individual state standards to the new Common Core State Standards, which will be fewer, higher, and more rigorous than most current state standards. As the next generation of assessments used for accountability are rolled…

  19. Standards of Ombudsman Assessment: A New Normative Concept?

    Directory of Open Access Journals (Sweden)

    Milan Remac

    2013-07-01

    Full Text Available Today, an ombudsman is a traditional component of democratic legal systems. Generally, reports of the ombudsman are not legally binding. Due to this fact, the ombudsman can rely only on his own persuasiveness, on his acceptance by individuals and state institutions, on the understanding of the administration and on the accessibility and transparency of rules that underpin his reports. During investigations, ombudsmen assess whether the administration has acted in accordance with certain legal or extra-legal standards. Depending on the legal system, ombudsmen can investigate whether there is an instance of maladministration in the activities of administrative bodies, whether the administration has acted ‘properly’, whether it has acted in accordance with the law, whether administrative actions have breached the human rights of complainants or whether the actions of the administration were in accordance with anti-corruption rules etc. Regardless of the legislative standard of an ombudsman’s control, the ombudsman should consider and assess the situation described in complaints against certain criteria or against certain normative standards. A distinct set of standards which ombudsmen use during their investigation, or at least a clear statement of their assessment criteria, can increase the transparency of their procedures and the persuasiveness of their reports. Are the normative standards used by different ombudsmen the same? Do they possibly create a new normative concept? And can it possibly lead to a higher acceptance of their reports by the administration?

  20. A randomized trial of standardized nursing patient assessment using wireless devices.

    Science.gov (United States)

    Dykes, Patricia C; Carroll, Diane L; Benoit, Angela; Coakley, Amanda; Chang, Frank; Empoliti, Joanne; Gallagher, Joan; Lasala, Cynthia; O'Malley, Rosemary; Rath, Greg; Silva, Judy; Li, Qi

    2007-10-11

    A complete and accurate patient assessment database is essential for effective communication, problem identification, planning and evaluation of patient status. When employed consistently for point-of-care documentation, information systems are associated with completeness and quality of documentation. The purpose of this paper is to report on the findings of a randomized, cross-over study conducted to evaluate the adequacy of a standard patient assessment module to support problem identification, care planning and tracking of nursing sensitive patient outcomes. The feasibility of wireless devices to support patient assessment data collection at the point-of-care was evaluated using wireless PDAs and tablet PCs. Seventy-nine (79) nurses from two patient care units at Massachusetts General Hospital (Boston, MA) were recruited into the study and randomized to complete patient assessment using wireless or paper devices. At the end of six weeks, nurses who where randomized to the paper assessment module were assigned to a device and those who used a device were assigned to paper for an additional six weeks. Impact was evaluated with regard to data capture, workflow implications and nurse satisfaction. Findings suggest that a standard patient assessment set promotes patient sensitive and quality data capture, which is augmented by the use of wireless devices.

  1. The Centrality of Teachers' Judgement Practice in Assessment: A Study of Standards in Moderation

    Science.gov (United States)

    Wyatt-Smith, Claire; Klenowski, Val; Gunn, Stephanie

    2010-01-01

    There is a strong quest in several countries including Australia for greater national consistency in education and intensifying interest in standards for reporting. Given this, it is important to make explicit the intended and unintended consequences of assessment reform strategies and the pressures to pervert and conform. In a policy context that…

  2. 24 CFR 115.206 - Performance assessments; Performance standards.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Performance assessments; Performance standards. 115.206 Section 115.206 Housing and Urban Development Regulations Relating to Housing... AGENCIES Certification of Substantially Equivalent Agencies § 115.206 Performance assessments; Performance...

  3. 7 CFR 319.40-11 - Plant pest risk assessment standards.

    Science.gov (United States)

    2010-01-01

    ... analysis to determine the plant pest risks associated with each requested importation in order to determine... 7 Agriculture 5 2010-01-01 2010-01-01 false Plant pest risk assessment standards. 319.40-11... Unmanufactured Wood Articles § 319.40-11 Plant pest risk assessment standards. When evaluating a request to...

  4. Standardized Handwriting to Assess Bradykinesia, Micrographia and Tremor in Parkinson's Disease

    NARCIS (Netherlands)

    Smits, Esther J.; Tolonen, Antti J.; Cluitmans, Luc; van Gils, Mark; Conway, Bernard A.; Zietsma, Rutger C.; Leenders, Klaus L.; Maurits, Natasha M.

    2014-01-01

    Objective: To assess whether standardized handwriting can provide quantitative measures to distinguish patients diagnosed with Parkinson's disease from age- and gender-matched healthy control participants. Design: Exploratory study. Pen tip trajectories were recorded during circle, spiral and line

  5. Standards for psychological assessment of nuclear facility personnel. Technical report

    International Nuclear Information System (INIS)

    Frank, F.D.; Lindley, B.S.; Cohen, R.A.

    1981-07-01

    The subject of this study was the development of standards for the assessment of emotional instability in applicants for nuclear facility positions. The investigation covered all positions associated with a nuclear facility. Conclusions reached in this investigation focused on the ingredients of an integrated selection system including the use of personality tests, situational simulations, and the clinical interview; the need for professional standards to ensure quality control; the need for a uniform selection system as organizations vary considerably in terms of instruments presently used; and the need for an on-the-job behavioral observation program

  6. ASK Standards: Assessment, Skills, and Knowledge Content Standards for Student Affairs Practitioners and Scholars

    Science.gov (United States)

    ACPA College Student Educators International, 2011

    2011-01-01

    The Assessment Skills and Knowledge (ASK) standards seek to articulate the areas of content knowledge, skill and dispositions that student affairs professionals need in order to perform as practitioner-scholars to assess the degree to which students are mastering the learning and development outcomes the professionals intend. Consistent with…

  7. NUSS safety standards: A critical assessment

    International Nuclear Information System (INIS)

    Minogue, R.B.

    1985-01-01

    The NUSS safety standards are based on systematic review of safety criteria of many countries in a process carefully defined to assure completeness of coverage. They represent an international consensus of accepted safety principles and practices for regulation and for the design, construction, and operation of nuclear power plants. They are a codification of principles and practices already in use by some Member States. Thus, they are not standards which describe methodologies at their present state of evolution as a result of more recent experience and improvements in technological understanding. The NUSS standards assume an underlying body of national standards and a defined technological base. Detailed design and industrial practices vary between countries and the implementation of basic safety standards within countries has taken approaches that conform with national industrial practices. Thus, application of the NUSS standards requires reconciliation with the standards of the country where the reactor will be built as well as with the country from which procurement takes place. Experience in making that reconciliation will undoubtedly suggest areas of needed improvement. After the TMI accident a reassessment of the NUSS programme was made and it was concluded that, given the information at that time and the then level of technology, the basic approach was sound; the NUSS programme should be continued to completion, and the standards should be brought into use. It was also recognized, however, that in areas such as probabilistic risk assessment, human factors methodology, and consideration of detailed accident sequences, more advanced technology was emerging. As these technologies develop, and become more amenable to practical application, it is anticipated that the NUSS standards will need revision. Ideally those future revisions will also flow from experience in their use

  8. TDA Assessment of Recommendations for Space Data System Standards

    Science.gov (United States)

    Posner, E. C.; Stevens, R.

    1984-01-01

    NASA is participating in the development of international standards for space data systems. Recommendations for standards thus far developed are assessed. The proposed standards for telemetry coding and packet telemetry provide worthwhile benefit to the DSN; their cost impact to the DSN should be small. Because of their advantage to the NASA space exploration program, their adoption should be supported by TDA, JPL, and OSTDS.

  9. Framework for Designing The Assessment Models of Readiness SMEs to Adopt Indonesian National Standard (SNI), Case Study: SMEs Batik in Surakarta

    Science.gov (United States)

    Fahma, Fakhrina; Zakaria, Roni; Fajar Gumilang, Royan

    2018-03-01

    Since the ASEAN Economic Community (AEC) is released, the opportunity to expand market share has become very open, but the level of competition is also very high. Standardization is believed to be an important factor in seizing opportunities in the AEC’s era and other free trade agreements in the future. Standardization activities in industry can be proven by obtaining certification of SNI (Indonesian National Standard). This is a challenge for SMEs, considering that currently only 20% of SMEs had SNI certification both product and process. This research will be designed a model of readiness assessment to obtain SNI certification for SMEs. The stages of model development used an innovative approach by Roger (2003). Variables that affect the readiness of SMEs are obtained from product certification requirements established by BSN (National Standardization Agency) and LSPro (Certification body). This model will be used for mapping the readiness for SNI certification of SMEs’product. The level of readiness of SMEs is determined by the percentage of compliance with those requirements. Based on the result of this study, the five variables are determined as main aspects to assess SME readiness. For model validation, trials were conducted on Batik SMEs in Laweyan Surakarta.

  10. Variation in assessment and standard setting practices across UK undergraduate medicine and the need for a benchmark.

    Science.gov (United States)

    MacDougall, Margaret

    2015-10-31

    The principal aim of this study is to provide an account of variation in UK undergraduate medical assessment styles and corresponding standard setting approaches with a view to highlighting the importance of a UK national licensing exam in recognizing a common standard. Using a secure online survey system, response data were collected during the period 13 - 30 January 2014 from selected specialists in medical education assessment, who served as representatives for their respective medical schools. Assessment styles and corresponding choices of standard setting methods vary markedly across UK medical schools. While there is considerable consensus on the application of compensatory approaches, individual schools display their own nuances through use of hybrid assessment and standard setting styles, uptake of less popular standard setting techniques and divided views on norm referencing. The extent of variation in assessment and standard setting practices across UK medical schools validates the concern that there is a lack of evidence that UK medical students achieve a common standard on graduation. A national licensing exam is therefore a viable option for benchmarking the performance of all UK undergraduate medical students.

  11. Standardized assessment of infrared thermographic fever screening system performance

    Science.gov (United States)

    Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-03-01

    Thermal modalities represent the only currently viable mass fever screening approach for outbreaks of infectious disease pandemics such as Ebola and SARS. Non-contact infrared thermometers (NCITs) and infrared thermographs (IRTs) have been previously used for mass fever screening in transportation hubs such as airports to reduce the spread of disease. While NCITs remain a more popular choice for fever screening in the field and at fixed locations, there has been increasing evidence in the literature that IRTs can provide greater accuracy in estimating core body temperature if appropriate measurement practices are applied - including the use of technically suitable thermographs. Therefore, the purpose of this study was to develop a battery of evaluation test methods for standardized, objective and quantitative assessment of thermograph performance characteristics critical to assessing suitability for clinical use. These factors include stability, drift, uniformity, minimum resolvable temperature difference, and accuracy. Two commercial IRT models were characterized. An external temperature reference source with high temperature accuracy was utilized as part of the screening thermograph. Results showed that both IRTs are relatively accurate and stable (<1% error of reading with stability of +/-0.05°C). Overall, results of this study may facilitate development of standardized consensus test methods to enable consistent and accurate use of IRTs for fever screening.

  12. Physical Activity Stories: Assessing the "Meaning Standard" in Physical Education

    Science.gov (United States)

    Johnson, Tyler G.

    2016-01-01

    The presence of the "meaning standard" in both national and state content standards suggests that professionals consider it an important outcome of a quality physical education program. However, only 10 percent of states require an assessment to examine whether students achieve this standard. The purpose of this article is to introduce…

  13. Teacher Assessment Literacy: A Review of International Standards and Measures

    Science.gov (United States)

    DeLuca, Christopher; LaPointe-McEwan, Danielle; Luhanga, Ulemu

    2016-01-01

    Assessment literacy is a core professional requirement across educational systems. Hence, measuring and supporting teachers' assessment literacy have been a primary focus over the past two decades. At present, there are a multitude of assessment standards across the world and numerous assessment literacy measures that represent different…

  14. Standardized mean differences cause funnel plot distortion in publication bias assessments.

    Science.gov (United States)

    Zwetsloot, Peter-Paul; Van Der Naald, Mira; Sena, Emily S; Howells, David W; IntHout, Joanna; De Groot, Joris Ah; Chamuleau, Steven Aj; MacLeod, Malcolm R; Wever, Kimberley E

    2017-09-08

    Meta-analyses are increasingly used for synthesis of evidence from biomedical research, and often include an assessment of publication bias based on visual or analytical detection of asymmetry in funnel plots. We studied the influence of different normalisation approaches, sample size and intervention effects on funnel plot asymmetry, using empirical datasets and illustrative simulations. We found that funnel plots of the Standardized Mean Difference (SMD) plotted against the standard error (SE) are susceptible to distortion, leading to overestimation of the existence and extent of publication bias. Distortion was more severe when the primary studies had a small sample size and when an intervention effect was present. We show that using the Normalised Mean Difference measure as effect size (when possible), or plotting the SMD against a sample size-based precision estimate, are more reliable alternatives. We conclude that funnel plots using the SMD in combination with the SE are unsuitable for publication bias assessments and can lead to false-positive results.

  15. DEVELOPING STANDARDS FOR ASSESSING ENVIRONMENTAL CHEMICAL, PHYSICAL, AND BIOLOGICAL STRESSORS THROUGH ASTM COMMITTEE E47: A PAST FOUNDATION OF PROVEN STANDARDS, A FUTURE OF GREAT POTENTIAL AND OPPORTUNITY

    Science.gov (United States)

    Development of standards associated with assessing the bioavailability of contaminants in sediment will be used as a case study for how standards have been developed through Committee E47. In 1987, Committee E47 established Subcommittee E47.03 on Sediment Assessment and Toxicity....

  16. Transformative Shifts in Art History Teaching: The Impact of Standards-Based Assessment

    Science.gov (United States)

    Ormond, Barbara

    2011-01-01

    This article examines pedagogical shifts in art history teaching that have developed as a response to the implementation of a standards-based assessment regime. The specific characteristics of art history standards-based assessment in the context of New Zealand secondary schools are explained to demonstrate how an exacting form of assessment has…

  17. Assessing the Genetics Content in the Next Generation Science Standards.

    Science.gov (United States)

    Lontok, Katherine S; Zhang, Hubert; Dougherty, Michael J

    2015-01-01

    Science standards have a long history in the United States and currently form the backbone of efforts to improve primary and secondary education in science, technology, engineering, and math (STEM). Although there has been much political controversy over the influence of standards on teacher autonomy and student performance, little light has been shed on how well standards cover science content. We assessed the coverage of genetics content in the Next Generation Science Standards (NGSS) using a consensus list of American Society of Human Genetics (ASHG) core concepts. We also compared the NGSS against state science standards. Our goals were to assess the potential of the new standards to support genetic literacy and to determine if they improve the coverage of genetics concepts relative to state standards. We found that expert reviewers cannot identify ASHG core concepts within the new standards with high reliability, suggesting that the scope of content addressed by the standards may be inconsistently interpreted. Given results that indicate that the disciplinary core ideas (DCIs) included in the NGSS documents produced by Achieve, Inc. clarify the content covered by the standards statements themselves, we recommend that the NGSS standards statements always be viewed alongside their supporting disciplinary core ideas. In addition, gaps exist in the coverage of essential genetics concepts, most worryingly concepts dealing with patterns of inheritance, both Mendelian and complex. Finally, state standards vary widely in their coverage of genetics concepts when compared with the NGSS. On average, however, the NGSS support genetic literacy better than extant state standards.

  18. Assessing the Genetics Content in the Next Generation Science Standards.

    Directory of Open Access Journals (Sweden)

    Katherine S Lontok

    Full Text Available Science standards have a long history in the United States and currently form the backbone of efforts to improve primary and secondary education in science, technology, engineering, and math (STEM. Although there has been much political controversy over the influence of standards on teacher autonomy and student performance, little light has been shed on how well standards cover science content. We assessed the coverage of genetics content in the Next Generation Science Standards (NGSS using a consensus list of American Society of Human Genetics (ASHG core concepts. We also compared the NGSS against state science standards. Our goals were to assess the potential of the new standards to support genetic literacy and to determine if they improve the coverage of genetics concepts relative to state standards. We found that expert reviewers cannot identify ASHG core concepts within the new standards with high reliability, suggesting that the scope of content addressed by the standards may be inconsistently interpreted. Given results that indicate that the disciplinary core ideas (DCIs included in the NGSS documents produced by Achieve, Inc. clarify the content covered by the standards statements themselves, we recommend that the NGSS standards statements always be viewed alongside their supporting disciplinary core ideas. In addition, gaps exist in the coverage of essential genetics concepts, most worryingly concepts dealing with patterns of inheritance, both Mendelian and complex. Finally, state standards vary widely in their coverage of genetics concepts when compared with the NGSS. On average, however, the NGSS support genetic literacy better than extant state standards.

  19. Peer Review of Assessment Network: Supporting Comparability of Standards

    Science.gov (United States)

    Booth, Sara; Beckett, Jeff; Saunders, Cassandra

    2016-01-01

    Purpose: This paper aims to test the need in the Australian higher education (HE) sector for a national network for the peer review of assessment in response to the proposed HE standards framework and propose a sector-wide framework for calibrating and assuring achievement standards, both within and across disciplines, through the establishment of…

  20. The Impact of Early Exposure of Eighth Grade Math Standards on End of Grade Assessments

    Science.gov (United States)

    Robertson, Tonjai E.

    2016-01-01

    The purpose of this study was to examine the Cumberland County Schools district-wide issue surrounding the disproportional performance of eighth grade Math I students' proficiency scores on standardized end-of-grade and end-of-course assessments. The study focused on the impact of the school district incorporating eighth grade math standards in…

  1. 42 CFR 493.1299 - Standard: Postanalytic systems quality assessment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Postanalytic systems quality assessment. 493.1299 Section 493.1299 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH....1291. (b) The postanalytic systems quality assessment must include a review of the effectiveness of...

  2. 42 CFR 493.1249 - Standard: Preanalytic systems quality assessment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Preanalytic systems quality assessment. 493.1249 Section 493.1249 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH....1241 through 493.1242. (b) The preanalytic systems quality assessment must include a review of the...

  3. 42 CFR 493.1289 - Standard: Analytic systems quality assessment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Analytic systems quality assessment. 493.1289 Section 493.1289 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND... through 493.1283. (b) The analytic systems quality assessment must include a review of the effectiveness...

  4. Environmental assessment. Energy efficiency standards for consumer products

    Energy Technology Data Exchange (ETDEWEB)

    McSwain, Berah

    1980-06-01

    The Energy Policy and Conservation Act of 1975 requires DOE to prescribe energy efficiency standards for 13 consumer products. The Consumer Products Efficiency Standards (CPES) program covers: refrigerators and refrigerator-freezers, freezers, clothes dryers, water heaters, room air conditioners, home heating equipment, kitchen ranges and ovens, central air conditioners (cooling and heat pumps), furnaces, dishwashers, television sets, clothes washers, and humidifiers and dehumidifiers. This Environmental Assessment evaluates the potential environmental and socioeconomic impacts expected as a result of setting efficiency standards for all of the consumer products covered by the CPES program. DOE has proposed standards for eight of the products covered by the Program in a Notice of Proposed Rulemaking (NOPR). DOE expects to propose standards for home heating equipment, central air conditioners (heat pumps only), dishwashers, television sets, clothes washers, and humidifiers and dehumidifiers in 1981. No significant adverse environmental or socioeconomic impacts have been found to result from instituting the CPES.

  5. Standard setting and quality of assessment: A conceptual approach ...

    African Journals Online (AJOL)

    Quality performance standards and the effect of assessment outcomes are important in the educational milieu, as assessment remains the representative ... not be seen as a methodological process of setting pass/fail cut-off points only, but as a powerful catalyst for quality improvements in HPE by promoting excellence in ...

  6. Public School Finance Assessment Project Aligned with ELCC Standards

    Science.gov (United States)

    Risen, D. Michael

    2008-01-01

    This is a detailed description of an assessment that can be used in a graduate level of study in the area of public school finance. This has been approved by NCATE as meeting all of the stipulated ELCC standards for which it is designed (1.1, 1.2, 1.3, 1.4, 1.5, 2.1, 2.2, 2.3, 2.4, 3.1, 3.2, 3.3, 4.1, 4.2, 4.3, 5.1, 5.2, 5.3.). This course of…

  7. Accounting for the NCEA : Has the Transition to Standards-based Assessment Achieved its Objectives?

    Directory of Open Access Journals (Sweden)

    Stephen Agnew

    2010-12-01

    Full Text Available This paper identifies trends in secondary school accounting participation and achievement during the firstfive years of the full implementation of the National Certificate of Educational Achievement (NCEA in NewZealand schools. NCEA marks a shift from a norm-referenced assessment regime to standards-basedassessment. Literature suggests that standards-based assessment increases the academic performance ofminority ethnic groups (such as Maori and Pacific Island students, and low socio-economic status (SESstudents. The author pays particular attention to these groups and his analysis reveals some interestingresults: in accounting, the NCEA has not met expectations for these students. From 2004 to 2008, thenumber of low SES accounting students has dropped, as has the number of accounting standards entered andthe rates of achievement. Likewise, there has been no significant improvement in the academic performanceof Maori students taking accounting standards, while Pacific Island students have experienced a significantdecrease in achievement. The author also discusses how studying high school accounting impacts on tertiarylevel study and offers some future implications of this research.

  8. Assessing Quality of Data Standards: Framework and Illustration Using XBRL GAAP Taxonomy

    Science.gov (United States)

    Zhu, Hongwei; Wu, Harris

    The primary purpose of data standards or metadata schemas is to improve the interoperability of data created by multiple standard users. Given the high cost of developing data standards, it is desirable to assess the quality of data standards. We develop a set of metrics and a framework for assessing data standard quality. The metrics include completeness and relevancy. Standard quality can also be indirectly measured by assessing interoperability of data instances. We evaluate the framework using data from the financial sector: the XBRL (eXtensible Business Reporting Language) GAAP (Generally Accepted Accounting Principles) taxonomy and US Securities and Exchange Commission (SEC) filings produced using the taxonomy by approximately 500 companies. The results show that the framework is useful and effective. Our analysis also reveals quality issues of the GAAP taxonomy and provides useful feedback to taxonomy users. The SEC has mandated that all publicly listed companies must submit their filings using XBRL. Our findings are timely and have practical implications that will ultimately help improve the quality of financial data.

  9. Assessment of self-perception of physical fitness and proposal for standards among Chilean adolescent students: the EAPAF study.

    Science.gov (United States)

    Cossio-Bolaños, Marco; Vasquez, Pablo; Luarte-Rocha, Cristian; Sulla-Torres, José; Gómez Campos, Rossana

    2016-08-01

    Physical fitness may be assessed among children and adolescents in a quantitative and qualitative manner. At present, in Chile, there are no tools available to assess self-perception of physical fitness. Therefore, the purpose of this study was to develop a valid and reliable instrument that would allow to assess selfperception of physical fitness among adolescents and propose standards for age and sex. A survey was administered among adolescent students from six public schools in the Maule Region, Chile, selected in a probabilistic (stratified) fashion. To measure self-perception of physical fitness, a qualitative instrument was developed: the Self-Perception of Physical Fitness Scale (EAPAF, escala de autopercepcion de la aptitud fisica), which is made up of four dimensions and 18 questions. The LMS method (L: Box-Cox coefficient, M: median curve, and S: variation coefficient) was used to establish percentiles and propose references by dimension, age and sex. A total of 3060 adolescents (1702 boys and 1358 girls) aged 11.0 to 18.9 years old were included. The factor analysis evidenced four factors. Saturation values were above 0.40. The percentage of instrument explanation reached 54.24%. In terms of reliability, the 18 questions reflected that Cronbach's alpha was between 0.82 and 0.85. Percentiles (p15, p50 and p85) were developed to classify self-perception of physical fitness by dimension, age and sex. Boys showed higher scores in the self-perception of physical fitness scale when compared to girls (p 〈 0.001). The instrument developed in this study was valid and reliable. In addition, the standards proposed may become a useful tool to classify adolescents in relation to their selfperception of physical fitness. Sociedad Argentina de Pediatría.

  10. Establishment of quality assessment standard for mammographic equipment: evaluation of phantom and clinical images

    International Nuclear Information System (INIS)

    Lee, Sung Hoon; Choe, Yeon Hyeon; Chung, Soo Young

    2005-01-01

    The purpose of this study was to establish a quality standard for mammographic equipment Korea and to eventually improve mammographic quality in clinics and hospitals throughout Korea by educating technicians and clinic personnel. For the phantom test and on site assessment, we visited 37 sites and examined 43 sets of mammographic equipment. Items that were examined include phantom test, radiation dose measurement, developer assessment, etc. The phantom images were assessed visually and by optical density measurements. For the clinical image assessment, clinical images from 371 sites were examined following the new Korean standard for clinical image evaluation. The items examined include labeling, positioning, contrast, exposure, artifacts, collimation among others. Quality standard of mammographic equipment was satisfied in all equipment on site visits. Average mean glandular dose was 114.9 mRad. All phantom image test scores were over 10 points (average, 10.8 points). However, optical density measurements were below 1.2 in 9 sets of equipment (20.9%). Clinical image evaluation revealed appropriate image quality in 83.5%, while images from non-radiologist clinics were adequate in 74.6% (91/122), which was the lowest score of any group. Images were satisfactory in 59.0% (219/371) based on evaluation by specialists following the new Korean standard for clinical image evaluation. Satisfactory images had a mean score of 81.7 (1 S.D. =8.9) and unsatisfactory images had a mean score of 61.9 (1 S.D = 11). The correlation coefficient between the two observers was 0.93 (ρ < 0.01) in 49 consecutive cases. The results of the phantom tests suggest that optical density measurements should be performed as part of a new quality standard for mammographic equipment. The new clinical evaluation criteria that was used in this study can be implemented with some modifications for future mammography quality control by the Korean government

  11. Handbook on Life Cycle Assessment. Operational Guide to the ISO Standards

    Energy Technology Data Exchange (ETDEWEB)

    Guinee, J.B. [Centre of Environmental Studies, Leiden University, Leiden (Netherlands)

    2002-04-01

    In 1992 the Centre of Environmental Science (CML) at Leiden University, The Netherlands, published a Guide on Environmental Life Cycle Assessment (LCA) methodology, setting the standard for a long time. Since then LCA methodology has progressed enormously and the International Organization for Standardization (ISO) has published a series of Standards on LCA. These developments have now been incorporated into a new Handbook on LCA authored by CML in cooperation with a number of other important institutes in the area of LCA. The general aim of this Handbook on LCA is to provide a stepwise 'cookbook' with operational guidelines for conducting an LCA study step-by-step, justified by a scientific background document, based on the ISO Standards for LCA. The different ISO elements and requirements are made operational to the 'best available practice' for each step. CML is strongly involved in the development of a standard methodology to determine environmental impacts of products, i.e., LCA. This is done within international fora such as the Society for Environmental Toxicology and Chemistry (SETAC), the International Organization for Standardization (ISO), and the United Nations Environmental Programme (UNEP)

  12. Designing Standardized Patient Assessments to Measure SBIRT Skills

    Science.gov (United States)

    Wamsley, Maria A.; Julian, Katherine A.; O'Sullivan, Patricia; Satterfield, Jason M.; Satre, Derek D.; McCance-Katz, Elinore; Batki, Steven L.

    2013-01-01

    Objectives: Resident physicians report insufficient experience caring for patients with substance use disorders (SUDs). Resident training in Screening, Brief Intervention, and Referral to Treatment (SBIRT) has been recommended. We describe the development of a standardized patient (SP) assessment to measure SBIRT skills, resident perceptions of…

  13. Tracer methodology: an appropriate tool for assessing compliance with accreditation standards?

    Science.gov (United States)

    Bouchard, Chantal; Jean, Olivier

    2017-10-01

    Tracer methodology has been used by Accreditation Canada since 2008 to collect evidence on the quality and safety of care and services, and to assess compliance with accreditation standards. Given the importance of this methodology in the accreditation program, the objective of this study is to assess the quality of the methodology and identify its strengths and weaknesses. A mixed quantitative and qualitative approach was adopted to evaluate consistency, appropriateness, effectiveness and stakeholder synergy in applying the methodology. An online questionnaire was sent to 468 Accreditation Canada surveyors. According to surveyors' perceptions, tracer methodology is an effective tool for collecting useful, credible and reliable information to assess compliance with Qmentum program standards and priority processes. The results show good coherence between methodology components (appropriateness of the priority processes evaluated, activities to evaluate a tracer, etc.). The main weaknesses are the time constraints faced by surveyors and management's lack of cooperation during the evaluation of tracers. The inadequate amount of time allowed for the methodology to be applied properly raises questions about the quality of the information obtained. This study paves the way for a future, more in-depth exploration of the identified weaknesses to help the accreditation organization make more targeted improvements to the methodology. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Training in Vocational Assessment: Preparing Rehabilitation Counselors and Meeting the Requirements of the CORE Standards

    Science.gov (United States)

    Tansey, Timothy N.

    2008-01-01

    Assessment represents a foundational component of rehabilitation counseling services. The revised Council on Rehabilitation Education (CORE) standards implemented in 2004 resulted in the redesign of the knowledge and outcomes under the Assessment standard. The author reviews the current CORE standard for training in assessment within the context…

  15. Russian Language Development Assessment as a Standardized Technique for Assessing Communicative Function in Children Aged 3–9 Years

    Directory of Open Access Journals (Sweden)

    Prikhoda N.A.,

    2016-10-01

    Full Text Available The article describes the Russian Language Development Assessment, a standardized individual diagnostic tool for children aged from 3 to 9 that helps to assess the following components of a child’s communicative function: passive vocabulary, expressive vocabulary, knowledge of semantic constructs with logical, temporal and spatial relations, passive perception and active use of syntactic and morphological features of words in a sentence, active and passive phonological awareness, active and passive knowledge of syntactic structures and categories. The article provides descriptions of content and diagnostic procedures for all 7 subtests included in the assessment (Passive Vocabulary, Active Vocabulary, Linguistic Operators, Sentence structure, Word Structure, Phonology, Sentence Repetition. Basing on the data collected in the study that involved 86 first- graders of a Moscow school, the article analyzes the internal consistency and construct validity of each subtest of the technique. It concludes that the Russian Language Development Assessment technique can be of much use both in terms of diagnostic purposes and in supporting children with ASD taking into account the lack of standardized tools for language and speech development assessment in Russian and the importance of this measure in general.

  16. Assessment of the Japanese Energy Efficiency Standards Program

    Directory of Open Access Journals (Sweden)

    Jun Arakawa

    2015-03-01

    Full Text Available Japanese energy efficiency standards program for appliances is a unique program which sets and revises mandatory standards based on the products of the highest energy efficiency on the markets. This study assessed the cost-effectiveness of the standard settings for air conditioner as a major residential appliance or typical example in the program. Based on analyses of empirical data, the net costs and effects from 1999 to 2040 were estimated. When applying a discount rate of 3%, the cost of abating CO2 emissions realized through the considered standards was estimated to be -13700 JPY/t-CO2. The sensitivity analysis, however, showed the cost turns into positive at a discount rate of 26% or higher. The authors also revealed that the standards’ “excellent” cost-effectiveness largely depends on that of the 1st standard setting, and the CO2 abatement cost through the 2nd standard was estimated to be as high as 26800 JPY/t-CO2. The results imply that the government is required to be careful about the possible economic burden imposed when considering introducing new, additional standards.

  17. Convergence or Divergence: Alignment of Standards, Assessment, and Issues of Diversity.

    Science.gov (United States)

    Carter, Norvella, Ed.

    In this report, teacher educators scrutinize the relationships between the standards and assessment movement in education and the United States' increasingly multicultural population. The papers include: "Foreword" (Jacqueline Jordan Irvine); (1) "Diversity and Standards: Defining the Issues" (Norvella P. Carter); (2) "Accountability and…

  18. Planning the Unplanned Experiment: Assessing the Efficacy of Standards for Safety Critical Software

    Science.gov (United States)

    Graydon, Patrick J.; Holloway, C. Michael

    2015-01-01

    We need well-founded means of determining whether software is t for use in safety-critical applications. While software in industries such as aviation has an excellent safety record, the fact that software aws have contributed to deaths illustrates the need for justi ably high con dence in software. It is often argued that software is t for safety-critical use because it conforms to a standard for software in safety-critical systems. But little is known about whether such standards `work.' Reliance upon a standard without knowing whether it works is an experiment; without collecting data to assess the standard, this experiment is unplanned. This paper reports on a workshop intended to explore how standards could practicably be assessed. Planning the Unplanned Experiment: Assessing the Ecacy of Standards for Safety Critical Software (AESSCS) was held on 13 May 2014 in conjunction with the European Dependable Computing Conference (EDCC). We summarize and elaborate on the workshop's discussion of the topic, including both the presented positions and the dialogue that ensued.

  19. Xpand chest drain: assessing equivalence to current standard ...

    African Journals Online (AJOL)

    leakage from 'open to air' system or breakage of glass bottle (with associated risk to ... and an air-leak detection system. It is connected to a ... need to add water. Xpand chest drain: assessing equivalence to current standard therapy – a randomised controlled trial. CHARL COOPER, M.B. CH.B. TIMOTHY HARDCASTLE ...

  20. A Case Study of the Alignment between Curriculum and Assessment in the New York State Earth Science Standards-Based System

    Science.gov (United States)

    Contino, Julie

    2013-01-01

    In a standards-based system, it is important for all components of the system to align in order to achieve the intended goals. No Child Left Behind law mandates that assessments be fully aligned with state standards, be valid, reliable and fair, be reported to all stakeholders, and provide evidence that all students in the state are meeting the…

  1. Balance Assessment Practices and Use of Standardized Balance Measures Among Ontario Physical Therapists

    Science.gov (United States)

    Sibley, Kathryn M.; Straus, Sharon E.; Inness, Elizabeth L.; Salbach, Nancy M.

    2011-01-01

    Background Balance impairment is a significant problem for older adults, as it can influence daily functioning. Treating balance impairment in this population is a major focus of physical therapist practice. Objective The purpose of this study was to document current practices in clinical balance assessment and compare components of balance assessed and measures used across practice areas among physical therapists. Design This was a cross-sectional study. Methods A survey questionnaire was mailed to 1,000 practicing physical therapists in Ontario, Canada. Results Three hundred sixty-nine individuals completed the survey questionnaire. More than 80% of respondents reported that they regularly (more than 60% of the time) assessed postural alignment, static and dynamic stability, functional balance, and underlying motor systems. Underlying sensory systems, cognitive contributions to balance, and reactive control were regularly assessed by 59.6%, 55.0%, and 41.2% of the respondents, respectively. The standardized measures regularly used by the most respondents were the single-leg stance test (79.1%), the Berg Balance Scale (45.0%), and the Timed “Up & Go” Test (27.6%). There was considerable variation in the components of balance assessed and measures used by respondents treating individuals in the orthopedic, neurologic, geriatric, and general rehabilitation populations. Limitations The survey provides quantitative data about what is done to assess balance, but does not explain the factors influencing current practice. Conclusions Many important components of balance and standardized measures are regularly used by physical therapists to assess balance. Further research, however, is needed to understand the factors contributing to the relatively lower rates of assessing reactive control, the component of balance most directly responsible for avoiding a fall. PMID:21868613

  2. Higher Education Quality Assessment Model: Towards Achieving Educational Quality Standard

    Science.gov (United States)

    Noaman, Amin Y.; Ragab, Abdul Hamid M.; Madbouly, Ayman I.; Khedra, Ahmed M.; Fayoumi, Ayman G.

    2017-01-01

    This paper presents a developed higher education quality assessment model (HEQAM) that can be applied for enhancement of university services. This is because there is no universal unified quality standard model that can be used to assess the quality criteria of higher education institutes. The analytical hierarchy process is used to identify the…

  3. A study of science leadership and science standards in exemplary standards-based science programs

    Science.gov (United States)

    Carpenter, Wendy Renae

    The purpose for conducting this qualitative study was to explore best practices of exemplary standards-based science programs and instructional leadership practices in a charter high school and in a traditional high school. The focus of this study included how twelve participants aligned practices to National Science Education Standards to describe their science programs and science instructional practices. This study used a multi-site case study qualitative design. Data were obtained through a review of literature, interviews, observations, review of educational documents, and researcher's notes collected in a field log. The methodology used was a multi-site case study because of the potential, through cross analysis, for providing greater explanation of the findings in the study (Merriam, 1988). This study discovered six characteristics about the two high school's science programs that enhance the literature found in the National Science Education Standards; (a) Culture of expectations for learning-In exemplary science programs teachers are familiar with a wide range of curricula. They have the ability to examine critically and select activities to use with their students to promote the understanding of science; (b) Culture of varied experiences-In exemplary science programs students are provided different paths to learning, which help students, take in information and make sense of concepts and skills that are set forth by the standards; (c) Culture of continuous feedback-In exemplary science programs teachers and students work together to engage students in ongoing assessments of their work and that of others as prescribed in the standards; (d) Culture of Observations-In exemplary science programs students, teachers, and principals reflect on classroom instructional practices; teachers receive ongoing evaluations about their teaching and apply feedback towards improving practices as outlined in the standards; (e) Culture of continuous learning-In exemplary

  4. Towards identifying dyslexia in Standard Indonesian: the development of a reading assessment battery.

    Science.gov (United States)

    Jap, Bernard A J; Borleffs, Elisabeth; Maassen, Ben A M

    2017-01-01

    With its transparent orthography, Standard Indonesian is spoken by over 160 million inhabitants and is the primary language of instruction in education and the government in Indonesia. An assessment battery of reading and reading-related skills was developed as a starting point for the diagnosis of dyslexia in beginner learners. Founded on the International Dyslexia Association's definition of dyslexia, the test battery comprises nine empirically motivated reading and reading-related tasks assessing word reading, pseudoword reading, arithmetic, rapid automatized naming, phoneme deletion, forward and backward digit span, verbal fluency, orthographic choice (spelling), and writing. The test was validated by computing the relationships between the outcomes on the reading-skills and reading-related measures by means of correlation and factor analyses. External variables, i.e., school grades and teacher ratings of the reading and learning abilities of individual students, were also utilized to provide evidence of its construct validity. Four variables were found to be significantly related with reading-skill measures: phonological awareness, rapid naming, spelling, and digit span. The current study on reading development in Standard Indonesian confirms findings from other languages with transparent orthographies and suggests a test battery including preliminary norm scores for screening and assessment of elementary school children learning to read Standard Indonesian.

  5. Adherence of pain assessment to the German national standard for pain management in 12 nursing homes.

    Science.gov (United States)

    Osterbrink, Jürgen; Bauer, Zsuzsa; Mitterlehner, Barbara; Gnass, Irmela; Kutschar, Patrick

    2014-01-01

    Pain is very common among nursing home residents. The assessment of pain is a prerequisite for effective multiprofessional pain management. Within the framework of the German health services research project, 'Action Alliance Pain-Free City Muenster', the authors investigated pain assessment adherence according to the German national Expert Standard for Pain Management in Nursing, which is a general standard applicable to all chronic⁄acute pain-affected persons and highly recommended for practice. To evaluate the state of pain assessment and to identify need for improvement in 12 nursing homes in a German city. In the present study, the authors used an ex-post-facto design (survey methodology). Available written policies for routine pain assessment in residents ≥65 years of age were reviewed and a standardized online survey completed by 151 of 349 nurses in 12 nursing home facilities was conducted between September 2010 and April 2011. Most of the included nursing homes provided written policies for pain assessment, and the majority of nurses reported that they assess and regularly reassess pain. However, observational tools for residents with severe cognitive impairment and written reassessment schedules were lacking in many facilities or were inconsistent. Essentially, pain assessment appeared to be feasible in the majority of the German nursing homes studied. However, the absence or inconsistency of reassessment schedules indicate that pain management guidelines should include a detailed and explicit reassessment schedule for the heterogenic needs of nursing home residents. For residents with severe cognitive impairment, assessment tools are needed that are simple to use and clearly indicate the presence or absence of pain.

  6. Safety standards for near surface disposal and the safety case and supporting safety assessment for demonstrating compliance with the standards

    International Nuclear Information System (INIS)

    Metcalf, P.

    2003-01-01

    The report presents the safety standards for near surface disposal (ICRP guidance and IAEA standards) and the safety case and supporting safety assessment for demonstrating compliance with the standards. Special attention is paid to the recommendations for disposal of long-lived solid radioactive waste. The requirements are based on the principle for the same level of protection of future individuals as for the current generation. Two types of exposure are considered: human intrusion and natural processes and protection measures are discussed. Safety requirements for near surface disposal are discussed including requirements for protection of human health and environment, requirements or safety assessments, waste acceptance and requirements etc

  7. Brief International Cognitive Assessment for MS (BICAMS): international standards for validation.

    Science.gov (United States)

    Benedict, Ralph H B; Amato, Maria Pia; Boringa, Jan; Brochet, Bruno; Foley, Fred; Fredrikson, Stan; Hamalainen, Paivi; Hartung, Hans; Krupp, Lauren; Penner, Iris; Reder, Anthony T; Langdon, Dawn

    2012-07-16

    An international expert consensus committee recently recommended a brief battery of tests for cognitive evaluation in multiple sclerosis. The Brief International Cognitive Assessment for MS (BICAMS) battery includes tests of mental processing speed and memory. Recognizing that resources for validation will vary internationally, the committee identified validation priorities, to facilitate international acceptance of BICAMS. Practical matters pertaining to implementation across different languages and countries were discussed. Five steps to achieve optimal psychometric validation were proposed. In Step 1, test stimuli should be standardized for the target culture or language under consideration. In Step 2, examiner instructions must be standardized and translated, including all information from manuals necessary for administration and interpretation. In Step 3, samples of at least 65 healthy persons should be studied for normalization, matched to patients on demographics such as age, gender and education. The objective of Step 4 is test-retest reliability, which can be investigated in a small sample of MS and/or healthy volunteers over 1-3 weeks. Finally, in Step 5, criterion validity should be established by comparing MS and healthy controls. At this time, preliminary studies are underway in a number of countries as we move forward with this international assessment tool for cognition in MS.

  8. PET/CT assessment in follicular lymphoma using standardized criteria: central review in the PRIMA study

    Energy Technology Data Exchange (ETDEWEB)

    Tychyj-Pinel, Christelle [Service de Medecine Nucleaire, Hospices Civils de Lyon, Centre Hospitalier Lyon Sud, Pierre-Benite (France); Ricard, Fabien [Service de Medecine Nucleaire, Hospices Civils de Lyon, Centre Hospitalier Lyon Sud, Pierre-Benite (France); Universite de Lyon, Faculte de Medecine, UCB Lyon 1, Lyon (France); Fulham, Michael [Royal Prince Alfred Hospital, Department of PET and Nuclear Medicine, Sydney (Australia); University of Sydney, Sydney Medical School, Sydney (Australia); Fournier, Marion [Centre Hospitalier Lyon Sud, The Lymphoma Academic Research Organisation (LYSARC), Pierre-Benite (France); Meignan, Michel [CHU Henri Mondor, Medicine Nucleaire, Creteil (France); Lamy, Thierry [Service d' Hematologie, CHU, Rennes (France); Vera, Pierre [Centre Henri Becquerel, Service de Medecine Nucleaire, Rouen (France); Rouen University, QuantIF (Litis EA4108), Rouen (France); Salles, Gilles [Universite de Lyon, Faculte de Medecine, UCB Lyon 1, Lyon (France); Service d' Hematologie, Hospices Civils de Lyon, Centre Hospitalier Lyon Sud, Pierre-Benite (France); Trotman, Judith [University of Sydney, Sydney Medical School, Sydney (Australia); Concord Hospital, Department of Haematology, Concord, NSW (Australia)

    2014-03-15

    We aimed to compare the standardized central review of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT scans performed after induction therapy for follicular lymphoma (FL) in the PRIMA study (Salles et al., Lancet 377:42-51, 2011; Trotman et al., J Clin Oncol 29:3194-3200, 2011) to scan review at local centres. PET/CT scans were independently evaluated by two nuclear medicine physicians using the 2007 International Harmonization Project (IHP) criteria (Cheson et al., J Clin Oncol 25:579-586, 2007; Juweid et al., J Clin Oncol 25:571-578, 2007; Shankar et al., J Nucl Med 47:1059-1066, 2006) and Deauville 5-point scale (5PS) criteria (Meignan et al., Leuk Lymphoma 50:1257-1260, 2009; Meignan et al., Leuk Lymphoma 51:2171-2180, 2010; Barrington et al., Eur J Nucl Med Mol Imaging 37:1824-1833, 2010). PET/CT status was compared with prospectively recorded patient outcomes. Central evaluation was performed on 119 scans. At diagnosis, 58 of 59 were recorded as positive, with a mean maximum standardized uptake value (SUV{sub max}) of 11.7 (range 4.6-35.6). There was no significant association between baseline SUV{sub max} and progression-free survival (PFS). Sixty post-induction scans were interpreted using both the IHP criteria and 5PS. Post-induction PET-positive status failed to predict progression when applying the IHP criteria [p = 0.14; hazard ratio (HR) 1.9; 95 % confidence interval (CI) 0.8-4.6] or 5PS with a cut-off ≥3 (p = 0.12; HR 2.0; 95 % CI 0.8-4.7). However, when applying the 5PS with a cut-off ≥4, there was a significantly inferior 42-month PFS in PET-positive patients of 25.0 % (95 % CI 3.7-55.8 %) versus 61.4 % (95 % CI 45.4-74.1 %) in PET-negative patients (p = 0.01; HR 3.1; 95 % CI 1.2-7.8). The positive predictive value (PPV) of post-induction PET with this liver cut-off was 75 %. The 42-month PFS for patients remaining PET-positive by local assessment was 31.1 % (95 % CI 10.2-55.0 %) vs 64.6 % (95 % CI 47.0-77.6 %) for PET

  9. [COMPUTER TECHNOLOGY FOR ACCOUNTING OF CONFOUNDERS IN THE RISK ASSESSMENT IN COMPARATIVE STUDIES ON THE BASE OF THE METHOD OF STANDARDIZATION].

    Science.gov (United States)

    Shalaumova, Yu V; Varaksin, A N; Panov, V G

    2016-01-01

    There was performed an analysis of the accounting of the impact of concomitant variables (confounders), introducing a systematic error in the assessment of the impact of risk factors on the resulting variable. The analysis showed that standardization is an effective method for the reduction of the shift of risk assessment. In the work there is suggested an algorithm implementing the method of standardization based on stratification, providing for the minimization of the difference of distributions of confounders in groups on risk factors. To automate the standardization procedures there was developed a software available on the website of the Institute of Industrial Ecology, UB RAS. With the help of the developed software by numerically modeling there were determined conditions of the applicability of the method of standardization on the basis of stratification for the case of the normal distribution on the response and confounder and linear relationship between them. Comparison ofresults obtained with the help of the standardization with statistical methods (logistic regression and analysis of covariance) in solving the problem of human ecology, has shown that obtaining close results is possible if there will be met exactly conditions for the applicability of statistical methods. Standardization is less sensitive to violations of conditions of applicability.

  10. An empirical assessment of the impact of technical standards on the export of meat in Nigeria

    Directory of Open Access Journals (Sweden)

    Queeneth Odichi Ekeocha

    2017-10-01

    Full Text Available The study is an assessment of the impact of technical standards on meat export in Nigeria. Several literatures were reviewed in relation to meat standards, issues associated with standards compliance, the effects of SPS standards on food exports in developing countries, causes of non-export of meat in Nigeria, amongst others. A survey method was used and a cross tabulation analysis was made to ascertain the relationship among various variables and how significant they were in relation to food product standards. The findings of the study among others include- sanitary conditions for meat processing is a significant factor for meat export; standards compliance is a step in the right direction towards agricultural export diversification, food standard compliance can create market access for meat exports, etc. The study concluded that technical standard is very significant to meat exports in Nigeria. Therefore, the study recommends among others that the government should invest in the productive capacity of SPS requirements for meat export, standard abattoirs should be built and maintained, policymakers should re-think flexible export diversification policy that could attract foreign investor and meat companies in Nigeria.

  11. STAMINA - Model description. Standard Model Instrumentation for Noise Assessments

    NARCIS (Netherlands)

    Schreurs EM; Jabben J; Verheijen ENG; CMM; mev

    2010-01-01

    Deze rapportage beschrijft het STAMINA-model, dat staat voor Standard Model Instrumentation for Noise Assessments en door het RIVM is ontwikkeld. Het instituut gebruikt dit standaardmodel om omgevingsgeluid in Nederland in kaart te brengen. Het model is gebaseerd op de Standaard Karteringsmethode

  12. Edible safety requirements and assessment standards for agricultural genetically modified organisms.

    Science.gov (United States)

    Deng, Pingjian; Zhou, Xiangyang; Zhou, Peng; Du, Zhong; Hou, Hongli; Yang, Dongyan; Tan, Jianjun; Wu, Xiaojin; Zhang, Jinzhou; Yang, Yongcun; Liu, Jin; Liu, Guihua; Li, Yonghong; Liu, Jianjun; Yu, Lei; Fang, Shisong; Yang, Xiaoke

    2008-05-01

    This paper describes the background, principles, concepts and methods of framing the technical regulation for edible safety requirement and assessment of agricultural genetically modified organisms (agri-GMOs) for Shenzhen Special Economic Zone in the People's Republic of China. It provides a set of systematic criteria for edible safety requirements and the assessment process for agri-GMOs. First, focusing on the degree of risk and impact of different agri-GMOs, we developed hazard grades for toxicity, allergenicity, anti-nutrition effects, and unintended effects and standards for the impact type of genetic manipulation. Second, for assessing edible safety, we developed indexes and standards for different hazard grades of recipient organisms, for the influence of types of genetic manipulation and hazard grades of agri-GMOs. To evaluate the applicability of these criteria and their congruency with other safety assessment systems for GMOs applied by related organizations all over the world, we selected some agri-GMOs (soybean, maize, potato, capsicum and yeast) as cases to put through our new assessment system, and compared our results with the previous assessments. It turned out that the result of each of the cases was congruent with the original assessment.

  13. Tests of Alignment among Assessment, Standards, and Instruction Using Generalized Linear Model Regression

    Science.gov (United States)

    Fulmer, Gavin W.; Polikoff, Morgan S.

    2014-01-01

    An essential component in school accountability efforts is for assessments to be well-aligned with the standards or curriculum they are intended to measure. However, relatively little prior research has explored methods to determine statistical significance of alignment or misalignment. This study explores analyses of alignment as a special case…

  14. Assessing MBA Student Teamwork under the AACSB Assurance of Learning Standards

    Science.gov (United States)

    Procino, Matthew C.

    2012-01-01

    Since the 2003 release of the AACSB's Assurance of Learning standards, outcomes assessment has been a required practice for business schools wishing to receive their endorsement. While most accredited institutions had been dabbling with the measurement of student learning, the new standards raised the bar considerably. It is now necessary to…

  15. An Investigation of Item Type in a Standards-Based Assessment.

    Directory of Open Access Journals (Sweden)

    Liz Hollingworth

    2007-12-01

    Full Text Available Large-scale state assessment programs use both multiple-choice and open-ended items on tests for accountability purposes. Certainly, there is an intuitive belief among some educators and policy makers that open-ended items measure something different than multiple-choice items. This study examined two item formats in custom-built, standards-based tests of achievement in Reading and Mathematics at grades 3-8. In this paper, we raise questions about the value of including open-ended items, given scoring costs, time constraints, and the higher probability of missing data from test-takers.

  16. Using Microsoft Excel to Assess Standards: A "Techtorial". Article #2 in a 6-Part Series

    Science.gov (United States)

    Mears, Derrick

    2009-01-01

    Standards-based assessment is a term currently being used quite often in educational reform discussions. The philosophy behind this initiative is to utilize "standards" or "benchmarks" to focus instruction and assessments of student learning. The National Standards for Physical Education (NASPE, 2004) provide a framework to guide this process for…

  17. The Use of Bayesian Networks to Assess the Quality of Evidence from Research Synthesis: 2. Inter-Rater Reliability and Comparison with Standard GRADE Assessment.

    Directory of Open Access Journals (Sweden)

    Alexis Llewellyn

    Full Text Available The grades of recommendation, assessment, development and evaluation (GRADE approach is widely implemented in systematic reviews, health technology assessment and guideline development organisations throughout the world. We have previously reported on the development of the Semi-Automated Quality Assessment Tool (SAQAT, which enables a semi-automated validity assessment based on GRADE criteria. The main advantage to our approach is the potential to improve inter-rater agreement of GRADE assessments particularly when used by less experienced researchers, because such judgements can be complex and challenging to apply without training. This is the first study examining the inter-rater agreement of the SAQAT.We conducted two studies to compare: a the inter-rater agreement of two researchers using the SAQAT independently on 28 meta-analyses and b the inter-rater agreement between a researcher using the SAQAT (who had no experience of using GRADE and an experienced member of the GRADE working group conducting a standard GRADE assessment on 15 meta-analyses.There was substantial agreement between independent researchers using the Quality Assessment Tool for all domains (for example, overall GRADE rating: weighted kappa 0.79; 95% CI 0.65 to 0.93. Comparison between the SAQAT and a standard GRADE assessment suggested that inconsistency was parameterised too conservatively by the SAQAT. Therefore the tool was amended. Following amendment we found fair-to-moderate agreement between the standard GRADE assessment and the SAQAT (for example, overall GRADE rating: weighted kappa 0.35; 95% CI 0.09 to 0.87.Despite a need for further research, the SAQAT may aid consistent application of GRADE, particularly by less experienced researchers.

  18. 25 CFR 36.12 - Standard III-Program needs assessment.

    Science.gov (United States)

    2010-04-01

    ...., (1) Perceptions of the parents, tribes, educators, and the students with regard to the relevance and....12 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION MINIMUM ACADEMIC STANDARDS... Program Evaluation. This assessment shall include at least the following: (a) A clear statement of student...

  19. Assessing the Impact of Stricter Alcohol Advertising Standards: The Case of Beam Global Spirits.

    Science.gov (United States)

    Ross, Craig S; Sparks, Alicia; Jernigan, David H

    2016-08-01

    Reducing youth exposure to alcohol advertising is a global health priority. In most countries around the world, the alcohol industry is given the opportunity to regulate itself with respect to advertising practices. Generally, the alcohol industry self-regulations are lax, allowing youth to be disproportionately exposed to alcohol advertising. However, Beam Global Spirits and Wine (Beam) voluntarily adopted more restrictive advertising standards in the United States in 2007. This study assessed Beam's compliance with their new standard and estimates its effect on youth exposure and advertising costs. We found that Beam's compliance with its more restrictive standards was imperfect, but never-the-less, we estimated that youth exposure to alcohol advertising was reduced compared to other spirits brands. Beam's more restrictive standards did not increase their advertising costs and therefore other alcohol companies should consider adopting similar standards around the world.

  20. Towards continuous improvement of endoscopy standards: Validation of a colonoscopy assessment form.

    LENUS (Irish Health Repository)

    2012-02-01

    Aim: Assessment of procedural colonoscopy skills is an important and topical. The aim of this study was to develop and validate a competency-based colonoscopy assessment form that would be easy to use, suitable for the assessment of junior and senior endoscopists and potentially be a useful instrument to detect differences in performance standards following different training interventions. Method: A standardised assessment form was developed incorporating a checklist with dichotomous yes\\/no responses and a global assessment section incorporating several different elements. This form was used prospectively to evaluate colonoscopy cases during the period of the study in several university teaching hospitals. Results were analysed using ANOVA with Bonferroni corrections for post-hoc analysis. Results: 81 procedures were assessed, performed by eight consultant and 19 trainee endoscopists. There were no serious errors. When divided into three groups based on previous experience (novice, intermediate and expert) the assessment form demonstrated statistically significant differences between all three groups (p<0.05). When separate elements were taken into account, the global assessment section was a better discriminator of skill level than the checklist. Conclusion: This form is a valid, easy to use assessment method. We intend to use it to assess the value of simulator training in trainee endoscopists. It also has the potential to be a useful training tool when feedback is given to the trainee.

  1. Setting Proficiency Standards for School Leadership Assessment: An Examination of Cut Score Decision Making

    Science.gov (United States)

    Cravens, Xiu Chen; Goldring, Ellen B.; Porter, Andrew C.; Polikoff, Morgan S.; Murphy, Joseph; Elliott, Stephen N.

    2013-01-01

    Purpose: Performance evaluation informs professional development and helps school personnel improve student learning. Although psychometric literature indicates that a rational, sound, and coherent standard-setting process adds to the credibility of an assessment, few studies have empirically examined the decision-making process. This article…

  2. A comparison of two standard-setting approaches in high-stakes clinical performance assessment using generalizability theory.

    Science.gov (United States)

    Richter Lagha, Regina A; Boscardin, Christy K; May, Win; Fung, Cha-Chi

    2012-08-01

    Scoring clinical assessments in a reliable and valid manner using criterion-referenced standards remains an important issue and directly affects decisions made regarding examinee proficiency. This generalizability study of students' clinical performance examination (CPX) scores examines the reliability of those scores and of their interpretation, particularly according to a newly introduced, "critical actions" criterion-referenced standard and scoring approach. The authors applied a generalizability framework to the performance scores of 477 third-year students attending three different medical schools in 2008. The norm-referenced standard included all station checklist items. The criterion-referenced standard included only those items deemed critical to patient care by a faculty panel. The authors calculated and compared variance components and generalizability coefficients for each standard across six common stations. Norm-referenced scores had moderate generalizability (ρ = 0.51), whereas criterion-referenced scores showed low dependability (φ = 0.20). The estimated 63% of measurement error associated with the person-by-station interaction suggests case specificity. Increasing the number of stations on the CPX from 6 to 24, an impractical solution both for cost and time, would still yield only moderate dependability (φ = 0.50). Though the performance assessment of complex skills, like clinical competence, seems intrinsically valid, careful consideration of the scoring standard and approach is needed to avoid misinterpretation of proficiency. Further study is needed to determine how best to improve the reliability of criterion-referenced scores, by implementing changes to the examination structure, the process of standard-setting, or both.

  3. Technical Standards on the Safety Assessment of a HLW Repository in Other Countries

    International Nuclear Information System (INIS)

    Lee, Sung Ho; Hwang, Yong Soo

    2009-01-01

    The basic function of HLW disposal system is to prevent excessive radio-nuclides being leaked from the repository in a short time. To do this, many technical standards should be developed and established on the components of disposal system. Safety assessment of a repository is considered as one of technical standards, because it produces quantitative results of the future evolution of a repository based on a reasonably simplified model. In this paper, we investigated other countries' regulations related to safely assessment focused on the assessment period, radiation dose limits and uncertainties of the assessment. Especially, in the investigation process of the USA regulations, the USA regulatory bodies' approach to assessment period and peak dose is worth taking into account in case of a conflict between peak dose from safety assessment and limited value in regulation.

  4. A Student Assessment Tool for Standardized Patient Simulations (SAT-SPS): Psychometric analysis.

    Science.gov (United States)

    Castro-Yuste, Cristina; García-Cabanillas, María José; Rodríguez-Cornejo, María Jesús; Carnicer-Fuentes, Concepción; Paloma-Castro, Olga; Moreno-Corral, Luis Javier

    2018-05-01

    The evaluation of the level of clinical competence acquired by the student is a complex process that must meet various requirements to ensure its quality. The psychometric analysis of the data collected by the assessment tools used is a fundamental aspect to guarantee the student's competence level. To conduct a psychometric analysis of an instrument which assesses clinical competence in nursing students at simulation stations with standardized patients in OSCE-format tests. The construct of clinical competence was operationalized as a set of observable and measurable behaviors, measured by the newly-created Student Assessment Tool for Standardized Patient Simulations (SAT-SPS), which was comprised of 27 items. The categories assigned to the items were 'incorrect or not performed' (0), 'acceptable' (1), and 'correct' (2). 499 nursing students. Data were collected by two independent observers during the assessment of the students' performance at a four-station OSCE with standardized patients. Descriptive statistics were used to summarize the variables. The difficulty levels and floor and ceiling effects were determined for each item. Reliability was analyzed using internal consistency and inter-observer reliability. The validity analysis was performed considering face validity, content and construct validity (through exploratory factor analysis), and criterion validity. Internal reliability and inter-observer reliability were higher than 0.80. The construct validity analysis suggested a three-factor model accounting for 37.1% of the variance. These three factors were named 'Nursing process', 'Communication skills', and 'Safe practice'. A significant correlation was found between the scores obtained and the students' grades in general, as well as with the grades obtained in subjects with clinical content. The assessment tool has proven to be sufficiently reliable and valid for the assessment of the clinical competence of nursing students using standardized patients

  5. Safety assessment standards for modern plants in the UK

    International Nuclear Information System (INIS)

    Harbison, S.A.; Hannaford, J.

    1993-01-01

    The NII has revised its safety assessment principles (SAPs). This paper discusses the revised SAPs and their links with international standards. It considers the licensing of foreign designs of plant - a matter under active consideration in the UK -and discusses how the SAPs and the licensing process cater for that possibility. (author)

  6. Role of renal function in risk assessment of target non-attainment after standard dosing of meropenem in critically ill patients: a prospective observational study.

    Science.gov (United States)

    Ehmann, Lisa; Zoller, Michael; Minichmayr, Iris K; Scharf, Christina; Maier, Barbara; Schmitt, Maximilian V; Hartung, Niklas; Huisinga, Wilhelm; Vogeser, Michael; Frey, Lorenz; Zander, Johannes; Kloft, Charlotte

    2017-10-21

    Severe bacterial infections remain a major challenge in intensive care units because of their high prevalence and mortality. Adequate antibiotic exposure has been associated with clinical success in critically ill patients. The objective of this study was to investigate the target attainment of standard meropenem dosing in a heterogeneous critically ill population, to quantify the impact of the full renal function spectrum on meropenem exposure and target attainment, and ultimately to translate the findings into a tool for practical application. A prospective observational single-centre study was performed with critically ill patients with severe infections receiving standard dosing of meropenem. Serial blood samples were drawn over 4 study days to determine meropenem serum concentrations. Renal function was assessed by creatinine clearance according to the Cockcroft and Gault equation (CLCR CG ). Variability in meropenem serum concentrations was quantified at the middle and end of each monitored dosing interval. The attainment of two pharmacokinetic/pharmacodynamic targets (100%T >MIC , 50%T >4×MIC ) was evaluated for minimum inhibitory concentration (MIC) values of 2 mg/L and 8 mg/L and standard meropenem dosing (1000 mg, 30-minute infusion, every 8 h). Furthermore, we assessed the impact of CLCR CG on meropenem concentrations and target attainment and developed a tool for risk assessment of target non-attainment. Large inter- and intra-patient variability in meropenem concentrations was observed in the critically ill population (n = 48). Attainment of the target 100%T >MIC was merely 48.4% and 20.6%, given MIC values of 2 mg/L and 8 mg/L, respectively, and similar for the target 50%T >4×MIC . A hyperbolic relationship between CLCR CG (25-255 ml/minute) and meropenem serum concentrations at the end of the dosing interval (C 8h ) was derived. For infections with pathogens of MIC 2 mg/L, mild renal impairment up to augmented renal function was

  7. Towards a Standardized e-Assessment System: Motivations, Challenges and First Findings

    Directory of Open Access Journals (Sweden)

    Denis Helic

    2009-10-01

    Full Text Available “Global Learning” with shared learning contents, resources, activities and goals is one of the contributions of Globalization. With the capability to use new Information and Communication Technologies (ICT it is a bit easier to have a technology based learning systems that enable learners to share the learning resources and possibilities. As a result many Learning Management Systems (LMS were developed with divers of platforms and approaches. Consequently, sharing learning resources and components has become a major challenge. E-assessment as a primary activity of any LMS is facing the same challenges and problems. In order to stand on this challenge people in the field of technology enhanced learning have recommended that LMS should conform to specific standards. This paper discuses this challenge, the consequences and limitations of standards in the modern learning settings. Moreover, it shows a service oriented framework for assessment which aims to make the e-assessment systems flexible and also to initiate the term of “Global Learning Assessment” with the possibility of sharing the e-assessment system components.

  8. Risk Assessment Stability: A Revalidation Study of the Arizona Risk/Needs Assessment Instrument

    Science.gov (United States)

    Schwalbe, Craig S.

    2009-01-01

    The actuarial method is the gold standard for risk assessment in child welfare, juvenile justice, and criminal justice. It produces risk classifications that are highly predictive and that may be robust to sampling error. This article reports a revalidation study of the Arizona Risk/Needs Assessment instrument, an actuarial instrument for juvenile…

  9. Improving the Memory Sections of the Standardized Assessment of Concussion Using Item Analysis

    Science.gov (United States)

    McElhiney, Danielle; Kang, Minsoo; Starkey, Chad; Ragan, Brian

    2014-01-01

    The purpose of the study was to improve the immediate and delayed memory sections of the Standardized Assessment of Concussion (SAC) by identifying a list of more psychometrically sound items (words). A total of 200 participants with no history of concussion in the previous six months (aged 19.60 ± 2.20 years; N?=?93 men, N?=?107 women)…

  10. 77 FR 23250 - HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations

    Science.gov (United States)

    2012-04-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations AGENCY: Office of the National Coordinator for Health Information... 2009 mandates that the HIT Standards Committee develop a schedule for the assessment of policy...

  11. 76 FR 25355 - HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations

    Science.gov (United States)

    2011-05-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations AGENCY: Office of the National Coordinator for Health Information... 2009 mandates that the HIT Standards Committee develop a schedule for the assessment of policy...

  12. 78 FR 29134 - HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations

    Science.gov (United States)

    2013-05-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations AGENCY: Office of the National Coordinator for Health Information... 2009 mandates that the HIT Standards Committee develop a schedule for the assessment of policy...

  13. Non-small cell carcinoma: Comparison of postoperative intra- and extrathoracic recurrence assessment capability of qualitatively and/or quantitatively assessed FDG-PET/CT and standard radiological examinations

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Yumiko, E-mail: onitan@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Hyogo (Japan); Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Hyogo (Japan); Koyama, Hisanobu; Nogami, Munenobu; Takenaka, Daisuke [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Hyogo (Japan); Matsumoto, Keiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Hyogo (Japan); Department of Radiology, Yamanashi University, Shimokato, Yamanashi (Japan); Yoshikawa, Takeshi; Matsumoto, Sumiaki [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Hyogo (Japan); Maniwa, Yoshimasa [Division of Thoracic Surgery, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Nishimura, Yoshihiro [Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Hyogo (Japan)

    2011-09-15

    Purpose: The purpose of this study was to compare the capability of integrated FDG-PET/CT for assessment of postoperative intra- and extrathoracic recurrence in non-small cell lung cancer (NSCLC) patients with that of standard radiological examinations. Materials and methods: A total of 121 consecutive pathologically diagnosed NSCLC patients (80 males, 41 females; mean age, 71 years) underwent pathologically and surgically confirmed complete resection, followed by prospective integrated FDG-PET/CT and standard radiological examinations. Final diagnosis of recurrence was based on the results of more than 12 months of follow-up and/or pathological examinations. The probability of recurrence was assessed with either method for each patient by using 5-point visual scoring system, and final diagnosis was made by consensus between two readers. ROC analysis was used to compare the capability of the two methods for assessment of postoperative recurrence on a per-patient basis. The ROC-based positive test was used to determine optimal cut-off value for FDG uptake measurement at a site suspected on the basis of qualitatively assessed PET/CT. Finally, sensitivities, specificities and accuracies of all methods were compared by means of McNemar's test. Results: Areas under the curve of qualitatively assessed PET/CT and standard radiological examinations showed no significant differences (p > 0.05). At an optimal cut-off value of 2.5, specificity and accuracy of quantitatively and qualitatively assessed PET/CT were significantly higher than those of qualitatively assessed PET/CT and standard radiological examinations (p < 0.05). Conclusion: Accuracy of assessment of postoperative intra- and extrathoracic recurrence in NSCLC patients by qualitative and/or quantitative FDG-PET/CT is equivalent to or higher than that by standard radiological examinations.

  14. Non-small cell carcinoma: Comparison of postoperative intra- and extrathoracic recurrence assessment capability of qualitatively and/or quantitatively assessed FDG-PET/CT and standard radiological examinations

    International Nuclear Information System (INIS)

    Onishi, Yumiko; Ohno, Yoshiharu; Koyama, Hisanobu; Nogami, Munenobu; Takenaka, Daisuke; Matsumoto, Keiko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Maniwa, Yoshimasa; Nishimura, Yoshihiro; Sugimura, Kazuro

    2011-01-01

    Purpose: The purpose of this study was to compare the capability of integrated FDG-PET/CT for assessment of postoperative intra- and extrathoracic recurrence in non-small cell lung cancer (NSCLC) patients with that of standard radiological examinations. Materials and methods: A total of 121 consecutive pathologically diagnosed NSCLC patients (80 males, 41 females; mean age, 71 years) underwent pathologically and surgically confirmed complete resection, followed by prospective integrated FDG-PET/CT and standard radiological examinations. Final diagnosis of recurrence was based on the results of more than 12 months of follow-up and/or pathological examinations. The probability of recurrence was assessed with either method for each patient by using 5-point visual scoring system, and final diagnosis was made by consensus between two readers. ROC analysis was used to compare the capability of the two methods for assessment of postoperative recurrence on a per-patient basis. The ROC-based positive test was used to determine optimal cut-off value for FDG uptake measurement at a site suspected on the basis of qualitatively assessed PET/CT. Finally, sensitivities, specificities and accuracies of all methods were compared by means of McNemar's test. Results: Areas under the curve of qualitatively assessed PET/CT and standard radiological examinations showed no significant differences (p > 0.05). At an optimal cut-off value of 2.5, specificity and accuracy of quantitatively and qualitatively assessed PET/CT were significantly higher than those of qualitatively assessed PET/CT and standard radiological examinations (p < 0.05). Conclusion: Accuracy of assessment of postoperative intra- and extrathoracic recurrence in NSCLC patients by qualitative and/or quantitative FDG-PET/CT is equivalent to or higher than that by standard radiological examinations.

  15. Development of standardized bioassay protocols for the toxicity assessment of waste, manufactured products, and effluents in Latin America: Venezuela, a Case Study

    International Nuclear Information System (INIS)

    Rodriquez-Grau, J.

    1993-01-01

    The present status of the toxicity assessment of industrial products in Latin America is well below North America/EC standards. As an example, most of Latin America regulatory laws regarding effluent discharge are still based upon concentration limits of certain major pollutants, and BOD/COD measurements; no reference is made to the necessity of aquatic bioassay toxicity data. Aware of this imperative need, the Venezuelan Petroleum Industry (PDVSA), through its R ampersand D Corporative branch (INTEVEP) gave priority to the development of standardized acute/sublethal toxicity test protocols as sound means of evaluating their products and wastes. Throughout this presentation, the Venezuelan case will be studied, showing strategies undertaken to accelerate protocol development. Results will show the assessment of 14 different protocols encompassing a variety of species of aquatic/terrestrial organisms, and a series of toxicity test endpoints including mortality, reproductive, biological and immunological measurements, most of which are currently in use or being developed. These protocols have already yielded useful results in numerous cases where toxicity assessment was required, including evaluations of effluent, oil dispersants, drilling fluids, toxic wastes, fossil fuels and newly developed products. The Venezuelan case demonstrates that the integration of Industry, Academia and Government, which is an essential part of SETAC's philosophy, is absolutely necessary for the successful advancement of environmental scientific/regulatory issues

  16. Future Directions in Assessment: Influences of Standards and Implications for Language Learning

    Science.gov (United States)

    Cox, Troy L.; Malone, Margaret E.; Winke, Paula

    2018-01-01

    As "Foreign Language Annals" concludes its 50th anniversary, it is fitting to review the past and peer into the future of standards-based education and assessment. Standards are a common yardstick used by educators and researchers as a powerful framework for conceptualizing teaching and measuring learner success. The impact of standards…

  17. Psychosocial Assessment as a Standard of Care in Pediatric Cancer

    NARCIS (Netherlands)

    Kazak, Anne E.; Abrams, Annah N.; Banks, Jaime; Christofferson, Jennifer; DiDonato, Stephen; Grootenhuis, Martha A.; Kabour, Marianne; Madan-Swain, Avi; Patel, Sunita K.; Zadeh, Sima; Kupst, Mary Jo

    2015-01-01

    This paper presents the evidence for a standard of care for psychosocial assessment in pediatric cancer. An interdisciplinary group of investigators utilized EBSCO, PubMed, PsycINFO, Ovid, and Google Scholar search databases, focusing on five areas: youth/family psychosocial adjustment, family

  18. EMPLACEMENT GANTRY ITS STANDARDS IDENTIFICATION STUDY

    International Nuclear Information System (INIS)

    Voegele, M.

    2005-01-01

    To date, the project has established ITS performance requirements for SSCs based on identification and categorization of event sequences that may result in a radiological release. These performance requirements are defined within the NSDB. Further, SSCs credited with performing safe functions are classified as ITS. In turn, perform confirmation for these SSCs is sought through the use of consensus code and standards. The purpose of this study is to identify applicable codes and standards for the WP Emplacement Gantry ITS SSCs. Further, this study will form the basis for selection and the extent of applicability of each code and standard. This study is based on the design development completed for LA only. Accordingly, identification of ITS SSCs beyond those defined within the NSDB are based on designs that may be subject to further development during detail design. Furthermore, several design alternatives may still be under consideration to satisfy certain safety functions, and that final selection will not be determined until further design development has occurred. Therefore, for completeness, throughout this study alternative designs currently under considered will be discussed. Further, the results of this study will be subject to evaluation as part of a follow-on GAP analysis study. Based on the results of this study the GAP analysis will evaluate each code and standard to ensure each ITS performance requirement is fully satisfied. When a performance requirement is not fully satisfied a ''gap'' is highlighted. Thereafter, the study will identify supplemental requirements to augment the code or standard to meet performance requirements. Further, the GAP analysis will identify non-standard areas of the design that will be subject to a Development Plan. Non-standard components and non-standard design configurations are defined as areas of the design that do not follow standard industry practices or codes and standards. Whereby, performance confirmation cannot be

  19. Standard Errors for National Trends in International Large-Scale Assessments in the Case of Cross-National Differential Item Functioning

    Science.gov (United States)

    Sachse, Karoline A.; Haag, Nicole

    2017-01-01

    Standard errors computed according to the operational practices of international large-scale assessment studies such as the Programme for International Student Assessment's (PISA) or the Trends in International Mathematics and Science Study (TIMSS) may be biased when cross-national differential item functioning (DIF) and item parameter drift are…

  20. MRI assessment of myelination: an age standardization

    Energy Technology Data Exchange (ETDEWEB)

    Staudt, M. (Kinderklinik Dritter Orden, Passau (Germany)); Schropp, C. (Kinderklinik Dritter Orden, Passau (Germany)); Staudt, F. (Kinderklinik Dritter Orden, Passau (Germany)); Obletter, N. (Radiologische Praxis, Klinikum Ingolstadt (Germany)); Bise, K. (Neuropathologisches Inst., Muenchen Univ. (Germany)); Breit, A. (MR Tomographie, Klinikum Passau (Germany)); Weinmann, H.M. (Kinderklinik Schwabing, Muenchen (Germany))

    1994-04-01

    777 cerebral MRI examinations of children aged 3 days to 14 years were staged for myelination to establish an age standardization. Staging was performed using a system proposed in a previous paper, separately ranking 10 different regions of the brain. Interpretation of the results led to the identification of foue clinical diagnoses that are frequently associated with delays in myelination: West syndrome, cerebral palsy, developmental retardation, and congenital anomalies. In addition, it was found that assessment of myelination in children with head injuries was not practical as alterations in MRI signal can simulate earlier stages of myelination. Age limits were therefore calculated from the case material after excluding all children with these conditions. When simplifications of the definition of the stages are applied, these age limits for the various stages of myelination of each of the 10 regions of the brain make the staging system applicable for routine assessment of myelination. (orig.)

  1. Motivational Effects of Standardized Language Assessment on Chinese Young Learners

    Science.gov (United States)

    Zhao, Chuqiao

    2016-01-01

    This review paper examines how standardized language assessment affects Chinese young learners' motivation for second-language learning. By presenting the historical and contemporary contexts of the testing system in China, this paper seeks to demonstrate the interrelationship among cultural, social, familial, and individual factors, which…

  2. Standardized Patients Provide a Reliable Assessment of Athletic Training Students' Clinical Skills

    Science.gov (United States)

    Armstrong, Kirk J.; Jarriel, Amanda J.

    2016-01-01

    Context: Providing students reliable objective feedback regarding their clinical performance is of great value for ongoing clinical skill assessment. Since a standardized patient (SP) is trained to consistently portray the case, students can be assessed and receive immediate feedback within the same clinical encounter; however, no research, to our…

  3. Computed-tomography-guided anatomic standardization for quantitative assessment of dopamine transporter SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Kota [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Imabayashi, Etsuko; Matsuda, Hiroshi [National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Sumida, Kaoru; Sone, Daichi; Kimura, Yukio; Sato, Noriko [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); Mukai, Youhei; Murata, Miho [National Center of Neurology and Psychiatry, Department of Neurology, Tokyo (Japan)

    2017-03-15

    For the quantitative assessment of dopamine transporter (DAT) using [{sup 123}I]FP-CIT single-photon emission computed tomography (SPECT) (DaTscan), anatomic standardization is preferable for achieving objective and user-independent quantification of striatal binding using a volume-of-interest (VOI) template. However, low accumulation of DAT in Parkinson's disease (PD) would lead to a deformation error when using a DaTscan-specific template without any structural information. To avoid this deformation error, we applied computed tomography (CT) data obtained using SPECT/CT equipment to anatomic standardization. We retrospectively analyzed DaTscan images of 130 patients with parkinsonian syndromes (PS), including 80 PD and 50 non-PD patients. First we segmented gray matter from CT images using statistical parametric mapping 12 (SPM12). These gray-matter images were then anatomically standardized using the diffeomorphic anatomical registration using exponentiated Lie algebra (DARTEL) algorithm. Next, DaTscan images were warped with the same parameters used in the CT anatomic standardization. The target striatal VOIs for decreased DAT in PD were generated from the SPM12 group comparison of 20 DaTscan images from each group. We applied these VOIs to DaTscan images of the remaining patients in both groups and calculated the specific binding ratios (SBRs) using nonspecific counts in a reference area. In terms of the differential diagnosis of PD and non-PD groups using SBR, we compared the present method with two other methods, DaTQUANT and DaTView, which have already been released as software programs for the quantitative assessment of DaTscan images. The SPM12 group comparison showed a significant DAT decrease in PD patients in the bilateral whole striatum. Of the three methods assessed, the present CT-guided method showed the greatest power for discriminating PD and non-PD groups, as it completely separated the two groups. CT-guided anatomic standardization using

  4. Clinical balance assessment: perceptions of commonly-used standardized measures and current practices among physiotherapists in Ontario, Canada.

    Science.gov (United States)

    Sibley, Kathryn M; Straus, Sharon E; Inness, Elizabeth L; Salbach, Nancy M; Jaglal, Susan B

    2013-03-20

    Balance impairment is common in multiple clinical populations, and comprehensive assessment is important for identifying impairments, planning individualized treatment programs, and evaluating change over time. However, little information is available regarding whether clinicians who treat balance are satisfied with existing assessment tools. In 2010 we conducted a cross-sectional survey of balance assessment practices among physiotherapists in Ontario, Canada, and reported on the use of standardized balance measures (Sibley et al. 2011 Physical Therapy; 91: 1583-91). The purpose of this study was to analyse additional survey data and i) evaluate satisfaction with current balance assessment practices and standardized measures among physiotherapists who treat adult or geriatric populations with balance impairment, and ii) identify factors associated with satisfaction. The questionnaire was distributed to 1000 practicing physiotherapists. This analysis focuses on questions in which respondents were asked to rate their general perceptions about balance assessment, the perceived utility of individual standardized balance measures, whether they wanted to improve balance assessment practices, and why. Data were summarized with descriptive statistics and utility of individual measures was compared across clinical practice areas (orthopaedic, neurological, geriatric or general rehabilitation). The questionnaire was completed by 369 respondents, of which 43.4% of respondents agreed that existing standardized measures of balance meet their needs. In ratings of individual measures, the Single Leg Stance test and Berg Balance Scale were perceived as useful for clinical decision-making and evaluating change over time by over 70% of respondents, and the Timed Up-and-Go test was perceived as useful for decision-making by 56.9% of respondents and useful for evaluating change over time by 62.9% of respondents, but there were significant differences across practice groups. Seventy

  5. A conceptual analysis of standard setting in large-scale assessments

    NARCIS (Netherlands)

    van der Linden, Willem J.

    1994-01-01

    Elements of arbitrariness in the standard setting process are explored, and an alternative to the use of cut scores is presented. The first part of the paper analyzes the use of cut scores in large-scale assessments, discussing three different functions: (1) cut scores define the qualifications used

  6. A generic standard for assessing and managing activities with significant risk to health and safety

    International Nuclear Information System (INIS)

    Wilde, T.S.; Sandquist, G.M.

    2005-01-01

    Some operations and activities in industry, business, and government can present an unacceptable risk to health and safety if not performed according to established safety practices and documented procedures. The nuclear industry has extensive experience and commitment to assessing and controlling such risks. This paper provides a generic standard based upon DOE Standard DOE-STD-3007- 93, Nov 1993, Change Notice No. 1, Sep 1998. This generic standard can be used to assess practices and procedures employed by any industrial and government entity to ensure that an acceptable level of safety and control prevail for such operations. When any activity and operation is determined to involve significant risk to health and safety to workers or the public, the organization should adopt and establish an appropriate standard and methodology to ensure that adequate health and safety prevail. This paper uses DOE experience and standards to address activities with recognized potential for impact upon health and safety. Existing and future assessments of health and safety issues can be compared and evaluated against this generic standard for insuring that proper planning, analysis, review, and approval have been made. (authors)

  7. Low-Dose and Standard-Dose Unenhanced Helical Computed Tomography for the Assessment of Acute Renal Colic: Prospective Comparative Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Soo; Hwang, Im Kyung; Choi, Yo Won; Namkung, Sook; Kim, Heung Cheol; Hwang, Woo Cheol; Choi, Kuk Myung; Park, Ji Kang; Han, Tae Il; Kang, Weechang [Cheju National Univ. College of Medicine, Jeju (Korea, Republic of). Dept. of Diagnostic Radiology

    2005-11-01

    Purpose: To compare the efficacy of low-dose and standard-dose computed tomography (CT) for the diagnosis of ureteral stones. Material and Methods: Unenhanced helical CT was performed with both a standard dose (260 mAs, pitch 1.5) and a low dose (50 mAs, pitch 1.5) in 121 patients suspected of having acute renal colic. The two studies were prospectively and independently interpreted for the presence and location of ureteral stones, abnormalities unrelated to stone disease, identification of secondary signs, i.e. hydronephrosis and perinephric stranding, and tissue rim sign. The standard-dose CT images were interpreted by one reviewer and the low-dose CT images independently by two reviewers unaware of the standard-dose CT findings. The findings of the standard and low-dose CT scans were compared with the exact McNemar test. Interobserver agreements were assessed with kappa analysis. The effective radiation doses resulting from two different protocols were calculated by means of commercially available software to which the Monte-Carlo phantom model was given. Results: The sensitivity, specificity, and accuracy of standard-dose CT for detecting ureteral stones were 99%, 93%, and 98%, respectively, whereas for the two reviewers the sensitivity of low-dose CT was 93% and 95%, specificity 86%, and accuracy 92% and 94%. We found no significant differences between standard-dose and low-dose CT in the sensitivity and specificity for diagnosing ureter stones ( P >0.05 for both). However, the sensitivity of low-dose CT for detection of 19 stones less than or equal to 2 mm in diameter was 79% and 68%, respectively, for the two reviewers. Low-dose CT was comparable to standard-dose CT in visualizing hydronephrosis and the tissue rim sign. Perinephric stranding was far less clear on low-dose CT. Low-dose CT had the same diagnostic performance as standard-dose CT in diagnosing alternative diseases. Interobserver agreement between the two low-dose CT reviewers in the diagnosis of

  8. Assess of the Status of the Karaj Operating Rooms in Comparison with International Standards in 2011

    Directory of Open Access Journals (Sweden)

    M.H. Naseri

    2012-10-01

    Full Text Available Background: Because of making money, the operating room (OR is known as the beating heart of any clinical & health center. The effective and regular activity of the operating room guarantees a sustainable income for the hospital. So, in order to provide high quality treatment and care services, and to save the health and safety of OR staff, exploiting standard equipments and spaces as well as employing professional and skilled personnel is necessary. This study was aimed to assess the status of the Karaj operating rooms from physical, safety, sterilization, staffing and equipment aspects in comparison to the International Standards. Methods: This sectional descriptive study was conducted in Alborz University of Medical Sciences in 2011. Samples were 10 operating room wards from 10 surgical hospitals. Data were collected by a 70 items check-list at 5 fields of physical, safety, sterilization, staffing and equipment conditions and then compared to the international standards. The data were recorded in SPSS software and analyzed by statistical methods. Results: The results showed that compared to the international standards, the physical aspect was 60.5%, safety aspect 66%, sterilization aspect 68%, staffing aspect 63%, and equipment aspect was 80% close to the standard criteria. On the whole, in 10 assessed hospitals, equipment aspect with 80% had the best and the physical aspect with 60.5% had the worst conditions respectively. Conclusion: Due to admission in different medical and paramedical programs in Alborz University of Medical Sciences, renovation of the ORs is essential for training skilled students. Considering the results of this study could help the University authorities to improve the current condition.

  9. Non-Standard Assessment Practices in the Evaluation of Communication in Australian Aboriginal Children

    Science.gov (United States)

    Gould, Judith

    2008-01-01

    Australian Aboriginal children typically receive communication assessment services from Standard Australian English (SAE) speaking non-Aboriginal speech-language pathologists (SLPs). Educational assessments, including intelligence testing, are also primarily conducted by non-Aboriginal educational professionals. While the current paper will show…

  10. Risk assessment using probabilistic standards

    International Nuclear Information System (INIS)

    Avila, R.

    2004-01-01

    A core element of risk is uncertainty represented by plural outcomes and their likelihood. No risk exists if the future outcome is uniquely known and hence guaranteed. The probability that we will die some day is equal to 1, so there would be no fatal risk if sufficiently long time frame is assumed. Equally, rain risk does not exist if there was 100% assurance of rain tomorrow, although there would be other risks induced by the rain. In a formal sense, any risk exists if, and only if, more than one outcome is expected at a future time interval. In any practical risk assessment we have to deal with uncertainties associated with the possible outcomes. One way of dealing with the uncertainties is to be conservative in the assessments. For example, we may compare the maximal exposure to a radionuclide with a conservatively chosen reference value. In this case, if the exposure is below the reference value then it is possible to assure that the risk is low. Since single values are usually compared; this approach is commonly called 'deterministic'. Its main advantage lies in the simplicity and in that it requires minimum information. However, problems arise when the reference values are actually exceeded or might be exceeded, as in the case of potential exposures, and when the costs for realizing the reference values are high. In those cases, the lack of knowledge on the degree of conservatism involved impairs a rational weighing of the risks against other interests. In this presentation we will outline an approach for dealing with uncertainties that in our opinion is more consistent. We will call it a 'fully probabilistic risk assessment'. The essence of this approach consists in measuring the risk in terms of probabilities, where the later are obtained from comparison of two probabilistic distributions, one reflecting the uncertainties in the outcomes and one reflecting the uncertainties in the reference value (standard) used for defining adverse outcomes. Our first aim

  11. Standards and measurements for assessing bone health-workshop report co-sponsored by the International Society for Clinical Densitometry (ISCD) and the National Institute of Standards and Technology (NIST).

    Science.gov (United States)

    Bennett, Herbert S; Dienstfrey, Andrew; Hudson, Lawrence T; Oreskovic, Tammy; Fuerst, Thomas; Shepherd, John

    2006-01-01

    This article reports and discusses the results of the recent ISCD-NIST Workshop on Standards and Measurements for Assessing Bone Health. The purpose of the workshop was to assess the status of efforts to standardize and compare results from dual-energy X-ray absorptiometry (DXA) scans, and then to identify and prioritize ongoing measurement and standards needs.

  12. A Mapmark method of standard setting as implemented for the National Assessment Governing Board.

    Science.gov (United States)

    Schulz, E Matthew; Mitzel, Howard C

    2011-01-01

    This article describes a Mapmark standard setting procedure, developed under contract with the National Assessment Governing Board (NAGB). The procedure enhances the bookmark method with spatially representative item maps, holistic feedback, and an emphasis on independent judgment. A rationale for these enhancements, and the bookmark method, is presented, followed by a detailed description of the materials and procedures used in a meeting to set standards for the 2005 National Assessment of Educational Progress (NAEP) in Grade 12 mathematics. The use of difficulty-ordered content domains to provide holistic feedback is a particularly novel feature of the method. Process evaluation results comparing Mapmark to Anghoff-based methods previously used for NAEP standard setting are also presented.

  13. A Comprehensive Evaluation of Standardized Assessment Tools in the Diagnosis of Fibromyalgia and in the Assessment of Fibromyalgia Severity

    Directory of Open Access Journals (Sweden)

    Chad S. Boomershine

    2012-01-01

    Full Text Available Standard assessments for fibromyalgia (FM diagnosis and core FM symptom domains are needed for biomarker development and treatment trials. Diagnostic and symptom assessments are reviewed and recommendations are made for standards. Recommendations for existing assessments include the American College of Rheumatology FM classification criteria using the manual tender point Survey for diagnosis, the brief pain inventory average pain visual analogue scale for pain intensity, the function subscale of the revised fibromyalgia impact questionnaire (FIQR for physical function, the patient global impression of change and FIQR for overall/global improvement, the hospital anxiety and depression scale depression subscale for depression, the multiple ability self-report questionnaire for cognitive dysfunction, the fatigue severity scale for fatigue, the FIQR for multidimensional function/health-related quality of life, the jenkins sleep scale for sleep disturbance, and the fibromyalgia intensity score for tenderness. Forthcoming assessments including the FIQR for diagnosis, NIH PROMIS, and FIBRO Change scales are discussed.

  14. DOE [Department of Energy]-Nuclear Energy Standards Program annual assessment, FY 1990

    International Nuclear Information System (INIS)

    Williams, D.L. Jr.

    1990-11-01

    To meet the objectives of the programs funded by the Department of Energy (DOE)-Nuclear Energy (NE) Technology Support Programs, the Performance Assurance Project Office (PAPO) administers a nuclear standards program and related activities and fosters the development and application of standards. This standards program is carried out in accordance with the principles in DOE Order 1300.2, Department of Energy Standards Program, December 18, 1980. The purposes of this effort, as set forth in three subtasks, are to (1) manage the NE Standards Program, (2) manage the development and maintenance of NE standards, and (3) operate an NE Standards Information Program. This report assesses the Performance Assurance Project Office (PAPO) activities in terms of the objectives of the Department of Energy-Nuclear Energy (DOE-NE) funded programs. To meet these objectives, PAPO administers a nuclear standards program and related activities and fosters the development and application of standards. This task is carried out in accordance with the principles set forth in DOE Order 1300.2, Department of Energy Standards Program, December 18, 1980, and DOE memorandum, Implementation of DOE Orders on Quality Assurance, Standards, and Unusual Occurrence Reporting for Nuclear Energy Programs, March 3, 1982, and with guidance from the DOE-NE Technology Support Programs. 1 tab. (JF)

  15. Regional drought assessment using a distributed hydrological model coupled with Standardized Runoff Index

    Directory of Open Access Journals (Sweden)

    H. Shen

    2015-05-01

    Full Text Available Drought assessment is essential for coping with frequent droughts nowadays. Owing to the large spatio-temporal variations in hydrometeorology in most regions in China, it is very necessary to use a physically-based hydrological model to produce rational spatial and temporal distributions of hydro-meteorological variables for drought assessment. In this study, the large-scale distributed hydrological model Variable Infiltration Capacity (VIC was coupled with a modified standardized runoff index (SRI for drought assessment in the Weihe River basin, northwest China. The result indicates that the coupled model is capable of reasonably reproducing the spatial distribution of drought occurrence. It reflected the spatial heterogeneity of regional drought and improved the physical mechanism of SRI. This model also has potential for drought forecasting, early warning and mitigation, given that accurate meteorological forcing data are available.

  16. Assessing the reliability of the borderline regression method as a standard setting procedure for objective structured clinical examination

    Directory of Open Access Journals (Sweden)

    Sara Mortaz Hejri

    2013-01-01

    Full Text Available Background: One of the methods used for standard setting is the borderline regression method (BRM. This study aims to assess the reliability of BRM when the pass-fail standard in an objective structured clinical examination (OSCE was calculated by averaging the BRM standards obtained for each station separately. Materials and Methods: In nine stations of the OSCE with direct observation the examiners gave each student a checklist score and a global score. Using a linear regression model for each station, we calculated the checklist score cut-off on the regression equation for the global scale cut-off set at 2. The OSCE pass-fail standard was defined as the average of all station′s standard. To determine the reliability, the root mean square error (RMSE was calculated. The R2 coefficient and the inter-grade discrimination were calculated to assess the quality of OSCE. Results: The mean total test score was 60.78. The OSCE pass-fail standard and its RMSE were 47.37 and 0.55, respectively. The R2 coefficients ranged from 0.44 to 0.79. The inter-grade discrimination score varied greatly among stations. Conclusion: The RMSE of the standard was very small indicating that BRM is a reliable method of setting standard for OSCE, which has the advantage of providing data for quality assurance.

  17. Framework for Assessing the ICT Competency in Teachers up to the Requirements of "Teacher" Occupational Standard

    Science.gov (United States)

    Avdeeva, Svetlana; Zaichkina, Olga; Nikulicheva, Nataliya; Khapaeva, Svetlana

    2016-01-01

    The paper deals with problems of working out a test framework for the assessment of teachers' ICT competency in line with the requirements of "Teacher" occupational standard. The authors have analyzed the known approaches to assessing teachers' ICT competency--ISTE Standards and UNESCO ICT CFT and have suggested their own approach to…

  18. The role of Health Impact Assessment in the setting of air quality standards: An Australian perspective

    Energy Technology Data Exchange (ETDEWEB)

    Spickett, Jeffery, E-mail: J.Spickett@curtin.edu.au [WHO Collaborating Centre for Environmental Health Impact Assessment (Australia); Faculty of Health Sciences, School of Public Health, Curtin University, Perth, Western Australia (Australia); Katscherian, Dianne [WHO Collaborating Centre for Environmental Health Impact Assessment (Australia); Faculty of Health Sciences, School of Public Health, Curtin University, Perth, Western Australia (Australia); Harris, Patrick [CHETRE — UNSW Research Centre for Primary Health Care and Equity, University of New South Wales (Australia)

    2013-11-15

    The approaches used for setting or reviewing air quality standards vary from country to country. The purpose of this research was to consider the potential to improve decision-making through integration of HIA into the processes to review and set air quality standards used in Australia. To assess the value of HIA in this policy process, its strengths and weaknesses were evaluated aligned with review of international processes for setting air quality standards. Air quality standard setting programmes elsewhere have either used HIA or have amalgamated and incorporated factors normally found within HIA frameworks. They clearly demonstrate the value of a formalised HIA process for setting air quality standards in Australia. The following elements should be taken into consideration when using HIA in standard setting. (a) The adequacy of a mainly technical approach in current standard setting procedures to consider social determinants of health. (b) The importance of risk assessment criteria and information within the HIA process. The assessment of risk should consider equity, the distribution of variations in air quality in different locations and the potential impacts on health. (c) The uncertainties in extrapolating evidence from one population to another or to subpopulations, especially the more vulnerable, due to differing environmental factors and population variables. (d) The significance of communication with all potential stakeholders on issues associated with the management of air quality. In Australia there is also an opportunity for HIA to be used in conjunction with the NEPM to develop local air quality standard measures. The outcomes of this research indicated that the use of HIA for air quality standard setting at the national and local levels would prove advantageous. -- Highlights: • Health Impact Assessment framework has been applied to a policy development process. • HIA process was evaluated for application in air quality standard setting.

  19. Therapeutic effect of acupuncture combining standard swallowing training for post-stroke dysphagia: A prospective cohort study.

    Science.gov (United States)

    Mao, Li-Ya; Li, Li-Li; Mao, Zhong-Nan; Han, Yan-Ping; Zhang, Xiao-Ling; Yao, Jun-Xiao; Li, Ming

    2016-07-01

    To assess the therapeutic effect of acupuncture combining standard swallowing training for patients with dysphagia after stroke. A total of 105 consecutively admitted patients with post-stroke dysphagia in the Affiliated Hospital of Gansu University of Chinese Medicine were included: 50 patients from the Department of Neurology and Rehabilitation received standard swallowing training and acupuncture treatment (acupuncture group); 55 patients from the Department of Neurology received standard swallowing training only (control group). Participants in both groups received 5-day therapy per week for a 4-week period. The primary outcome measures included the scores of Videofluoroscopic Swallow Study (VFSS) and the Standardized Swallowing Assessment (SSA); the secondary outcome measure was the Royal Brisbane Hospital Outcome Measure for Swallowing (RBHOMS), all of which were assessed before and after the 4-week treatment. A total of 98 subjects completed the study (45 in the acupuncture group and 53 in the control group). Significant differences were seen in VFSS, SSA and RBHOMS scores in each group after 4-week treatment as compared with before treatment (Pdysphagia, and acupuncture therapy is worth further investigation in the treatment of post-stroke dysphagia.

  20. Study on Extension of Standard Meteorological Data for Cities in South Korea Using ISO 15927-4

    Directory of Open Access Journals (Sweden)

    Yeweon Kim

    2017-11-01

    Full Text Available Accurate standard meteorological data sets for each city are essential elements to assess and analyze high-performance buildings quantitatively in order to ensure that they comply with energy saving policies of the nation. ECO2, which is an assessment program of building energy in Korea, has employed meteorological data of the closest city to the target location from 13 urban meteorological data references; the employment of this program has demonstrated the ability to reflect climatic differences between cities. The present study expanded urban meteorological data to ISO TRY (International Organization for Standard Test Reference Year, an international standard methodology that can calculate the data in a relatively simple manner using observed data in Korea, as much as possible in order to reflect meteorological data, including the air temperature relevant for heating and cooling energy as well as solar radiation (cooling/heating energy for each city, that affected the assessment of building energy the most. In the present study, existing data is expanded to a show the standard meteorological data of 66 cities that can be put into the Korean assessment program (ECO2. This data considered valid meteorological data (minimum statistical period, air temperature, relative humidity, wind, and solar radiation, etc. among manned and unmanned observational data obtained from 479 locations from 2001 to 2010. For cities other than the 66 aforementioned cities, zoning was conducted to separate cities that had and did not have the standard meteorological data using a cumulative temperature density graph. In this way, meteorological data can be available in all cities, which will enable more accurate simulation assessments on building energy.

  1. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  2. The development of methodological tools to assess the health sector with the resulting standardized index

    Directory of Open Access Journals (Sweden)

    Hansuvarova Evgenia Adolfovna

    2016-10-01

    The proposed assessment methodology resulting standardized health index in the various countries of the world allows you to define the country implementing an effective management strategy in the health sector. The leading positions belong to the countries where the state health policy has shown its greatest efficiency. This technique can be used not only for point scoring result of a standardized health index in the world, but also to assess in a particular country.

  3. A study on safety assessment methodology for a vitrification plant

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Y. C.; Lee, G. S.; Choi, Y. C.; Kim, G. H. [Yonsei Univ., Seoul (Korea, Republic of)

    2002-03-15

    In this study, the technical and regulatory status of radioactive waste vitrification technologies in foreign and domestic plants is investigated and analyzed, and then significant factors are suggested which must be contained in the final technical guideline or standard for the safety assessment of vitrification plants. Also, the methods to estimate the stability of vitrified waste forms are suggested with property analysis of them. The contents and scope of the study are summarized as follows : survey of the status on radioactive waste vitrification technologies in foreign and domestic plants, survey of the characterization methodology for radioactive waste form, analysis of stability for vitrified waste forms, survey and analysis of technical standards and regulations concerned with them in foreign and domestic plants, suggestion of significant factors for the safety assessment of vitrification plants, submission of regulated technical standard on radioactive waste vitrification plats.

  4. Standardized handwriting to assess bradykinesia, micrographia and tremor in Parkinson's disease.

    Directory of Open Access Journals (Sweden)

    Esther J Smits

    Full Text Available OBJECTIVE: To assess whether standardized handwriting can provide quantitative measures to distinguish patients diagnosed with Parkinson's disease from age- and gender-matched healthy control participants. DESIGN: Exploratory study. Pen tip trajectories were recorded during circle, spiral and line drawing and repeated character 'elelelel' and sentence writing, performed by Parkinson patients and healthy control participants. Parkinson patients were tested after overnight withdrawal of anti-Parkinsonian medication. SETTING: University Medical Center Groningen, tertiary care, the Netherlands. PARTICIPANTS: Patients with Parkinson's disease (n = 10; mean age 69.0 years; 6 male and healthy controls (n = 10; mean age 68.1 years; 6 male. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Movement time and velocity to detect bradykinesia and the size of writing to detect micrographia. A rest recording to investigate the presence of a rest-tremor, by frequency analysis. RESULTS: Mean disease duration in the Parkinson group was 4.4 years and the patients were in modified Hoehn-Yahr stages 1-2.5. In general, Parkinson patients were slower than healthy control participants. Median time per repetition, median velocity and median acceleration of the sentence task and median velocity of the elel task differed significantly between Parkinson patients and healthy control participants (all p<0.0014. Parkinson patients also wrote smaller than healthy control participants and the width of the 'e' in the elel task was significantly smaller in Parkinson patients compared to healthy control participants (p<0.0014. A rest-tremor was detected in the three patients who were clinically assessed as having rest-tremor. CONCLUSIONS: This study shows that standardized handwriting can provide objective measures for bradykinesia, tremor and micrographia to distinguish Parkinson patients from healthy control participants.

  5. The impact of statistical adjustment on conditional standard errors of measurement in the assessment of physician communication skills.

    Science.gov (United States)

    Raymond, Mark R; Clauser, Brian E; Furman, Gail E

    2010-10-01

    The use of standardized patients to assess communication skills is now an essential part of assessing a physician's readiness for practice. To improve the reliability of communication scores, it has become increasingly common in recent years to use statistical models to adjust ratings provided by standardized patients. This study employed ordinary least squares regression to adjust ratings, and then used generalizability theory to evaluate the impact of these adjustments on score reliability and the overall standard error of measurement. In addition, conditional standard errors of measurement were computed for both observed and adjusted scores to determine whether the improvements in measurement precision were uniform across the score distribution. Results indicated that measurement was generally less precise for communication ratings toward the lower end of the score distribution; and the improvement in measurement precision afforded by statistical modeling varied slightly across the score distribution such that the most improvement occurred in the upper-middle range of the score scale. Possible reasons for these patterns in measurement precision are discussed, as are the limitations of the statistical models used for adjusting performance ratings.

  6. From the Margins to the Spotlight: Diverse Deaf and Hard of Hearing Student Populations and Standardized Assessment Accessibility.

    Science.gov (United States)

    Cawthon, Stephanie

    2015-01-01

    Designing assessments and tests is one of the more challenging aspects of creating an accessible learning environment for students who are deaf or hard of hearing (DHH), particularly for deaf students with a disability (DWD). Standardized assessments are a key mechanism by which the educational system in the United States measures student progress, teacher effectiveness, and the impact of school reform. The diversity of student characteristics within DHH and DWD populations is only now becoming visible in the research literature relating to standardized assessments and their use in large-scale accountability reforms. The purpose of this article is to explore the theoretical frameworks surrounding assessment policy and practice, current research related to standardized assessment and students who are DHH and DWD, and potential implications for practice within both the assessment and instruction contexts.

  7. Exploring standardized precipitation evapotranspiration index for drought assessment in Bangladesh.

    Science.gov (United States)

    Miah, Md Giashuddin; Abdullah, Hasan Muhammad; Jeong, Changyoon

    2017-10-09

    Drought is a critical issue, and it has a pressing, negative impact on agriculture, ecosystems, livelihoods, food security, and sustainability. The problem has been studied globally, but its regional or even local dimension is sometimes overlooked. Local-level drought assessment is necessary for developing adaptation and mitigation strategies for that particular region. Keeping this in understanding, an attempt was made to create a detailed assessment of drought characteristics at the local scale in Bangladesh. Standardized precipitation evapotranspiration (SPEI) is a new drought index that mainly considers the rainfall and evapotranspiration data set. Globally, SPEI has become a useful drought index, but its local scale application is not common. SPEI base (0.5° grid data) for 110 years (1901-2011) was utilized to overcome the lack of long-term climate data in Bangladesh. Available weather data (1955-2011) from Bangladesh Meteorology Department (BMD) were analyzed to calculate SPEI weather station using the SPEI calculator. The drivers for climate change-induced droughts were characterized by residual temperature and residual rainfall data from different BMD stations. Grid data (SPEI base ) of 26 stations of BMD were used for drought mapping. The findings revealed that the frequency and intensity of drought are higher in the northwestern part of the country which makes it vulnerable to both extreme and severe droughts. Based on the results, the SPEI-based drought intensity and frequency analyses were carried out, emphasizing Rangpur (northwest region) as a hot spot, to get an insight of drought assessment in Bangladesh. The findings of this study revealed that SPEI could be a valuable tool to understand the evolution and evaluation of the drought induced by climate change in the country. The study also justified the immediate need for drought risk reduction strategies that should lead to relevant policy formulations and agricultural innovations for developing

  8. Assessment of the Impacts of Standards and Labeling Programs inMexico (four products).

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Itha; Pulido, Henry; McNeil, Michael A.; Turiel, Isaac; della Cava, Mirka

    2007-06-12

    This study analyzes impacts from energy efficiency standards and labeling in Mexico from 1994 through 2005 for four major products: household refrigerators, room air conditioners, three-phase (squirrel cage) induction motors, and clothes washers. It is a retrospective analysis, seeking to assess verified impacts on product efficiency in the Mexican market in the first ten years after standards were implemented. Such an analysis allows the Mexican government to compare actual to originally forecast program benefits. In addition, it provides an extremely valuable benchmark for other countries considering standards, and to the energy policy community as a whole. The methodology for evaluation begins with historical test data taken for a large number of models of each product type between 1994 and 2005. The pre-standard efficiency of models in 1994 is taken as a baseline throughout the analysis. Model efficiency data were provided by an independent certification laboratory (ANCE), which tested products as part of the certification and enforcement mechanism defined by the standards program. Using this data, together with economic and market data provided by both government and private sector sources, the analysis considers several types of national level program impacts. These include: Energy savings; Environmental (emissions) impacts, and Net financial impacts to consumers, manufacturers and utilities. Energy savings impacts are calculated using the same methodology as the original projections, allowing a comparison. Other impacts are calculated using a robust and sophisticated methodology developed by the Instituto de Investigaciones Electricas (IIE) and Lawrence Berkeley National Laboratory (LBNL), in a collaboration supported by the Collaborative Labeling and Standards Program (CLASP).

  9. Self-assessment: Strategy for higher standards, consistency, and performance

    International Nuclear Information System (INIS)

    Ide, W.E.

    1996-01-01

    In late 1994, Palo Verde operations underwent a transformation from a unitized structure to a single functional unit. It was necessary to build consistency in watchstanding practices and create a shared mission. Because there was a lack of focus on actual plant operations and because personnel were deeply involved with administrative tasks, command and control of evolutions were weak. Improvement was needed. Consistent performance standards have been set for all three operating units. These expectation focus on nuclear, radiological, and industrial safety. Straightforward descriptions of watchstanding and monitoring practices have been provided to all department personnel. The desired professional and leadership qualities for employee conduct have been defined and communicated thoroughly. A healthy and competitive atmosphere developed with the successful implementation of these standards. Overall performance improved. The auxiliary operators demonstrated increased pride and ownership in the performance of their work activities. In addition, their morale improved. Crew teamwork improved as well as the quality of shift briefs. There was a decrease in the noise level and the administrative functions in the control room. The use of self-assessment helped to anchor and define higher and more consistent standards. The proof of Palo Verde's success was evident when an Institute of Nuclear Power Operations finding was turned into a strength within 1 yr

  10. Incorporating Standardized Colleague Simulations in a Clinical Assessment Course and Evaluating the Impact on Interprofessional Communication.

    Science.gov (United States)

    Shrader, Sarah; Dunn, Brianne; Blake, Elizabeth; Phillips, Cynthia

    2015-05-25

    To determine the impact of incorporating standardized colleague simulations on pharmacy students' confidence and interprofessional communication skills. Four simulations using standardized colleagues portraying attending physicians in inpatient and outpatient settings were integrated into a required course. Pharmacy students interacted with the standardized colleagues using the Situation, Background, Assessment, Request/Recommendation (SBAR) communication technique and were evaluated on providing recommendations while on simulated inpatient rounds and in an outpatient clinic. Additionally, changes in student attitudes and confidence toward interprofessional communication were assessed with a survey before and after the standardized colleague simulations. One hundred seventy-one pharmacy students participated in the simulations. Student interprofessional communication skills improved after each simulation. Student confidence with interprofessional communication in both inpatient and outpatient settings significantly improved. Incorporation of simulations using standardized colleagues improves interprofessional communication skills and self-confidence of pharmacy students.

  11. Explosion approach for external safety assessment: a case study

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, D. Michael; Halford, Ann [Germanischer Lloyd, Loughborough (United Kingdom); Mendes, Renato F. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    Several questions related to the potential for explosions are explored as this became an important subject during an enterprise risk analysis. The understanding of explosions underwent a substantial evolution in the final 20 years of the 20{sup th} century following international research projects in Europe involving several research institutes, as well gas and oil companies. This led to the development of techniques that could be used to assess the potential consequences of explosions on oil, gas and petrochemical facilities. This paper presents an overview of the potential for explosions in communities close to industrial sites or pipelines right of way (RoW), where the standard explosion assessment methods cannot be applied. With reference to experimental studies, the potential for confined explosions in buildings and Vapor Cloud Explosions is explored. Vapor Cloud Explosion incidents in rural or urban areas are also discussed. The method used for incorporating possible explosion and fire events in risk studies is also described using a case study. Standard explosion assessment methodologies and a revised approach are compared as part of an on going evaluation of risk (author)

  12. Standardization of natural phenomena risk assessment methodology at the Savannah River Plant

    International Nuclear Information System (INIS)

    Huang, J.C.; Hsu, Y.S.

    1985-01-01

    Safety analyses at the Savannah River Plant (SRP) normally require consideration of the risks of incidents caused by natural events such as high-velocity straight winds, tornadic winds, and earthquakes. The probabilities for these events to occur at SRP had been studied independently by several investigators, but the results of their studies were never systematically evaluated. As part of the endeavor to standardize our environmental risk assessment methodology, these independent studies have been thoroughly reviewed and critiqued, and appropriate probability models for these natural events have been selected. The selected probability models for natural phenomena, high-velocity straight winds and tornadic winds in particular, are in agreement with those being used at other DOE sites, and have been adopted as a guide for all safety studies conducted for SRP operations and facilities. 7 references, 3 figures

  13. Radiation protection standards: A practical exercise in risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, Roger H [National Radiological Protection Board (United Kingdom)

    1992-07-01

    Within 12 months of the discovery of x-rays in 1895, it was reported that large doses of radiation were harmful to living human tissues. The first radiation protection standards were set to avoid the early effects of acute irradiation. By the 1950s, evidence was mounting for late somatic effects - mainly a small excess of cancers - in irradiated populations. In the late 1980's, sufficient human epidemiological data had been accumulated to allow a comprehensive assessment of carcinogenic radiation risks following the delivery of moderately high doses. Workers and the public are exposed to lower doses and dose-rates than the groups from whom good data are available so that risks have had to be estimated for protection purposes. However, in the 1990s, some confirmation of these risk factors has been derived occupationally exposed populations. If an estimate is made of the risk per unit dose, then in order to set dose limits, an unacceptable level of risk must be established for both workers and the public. There has been and continues to be a debate about the definitions of 'acceptable' and 'tolerable' and the attributing of numerical values to these definitions. This paper discusses the issues involved in the quantification of these terms and their application to setting dose limits on risk grounds. Conclusions are drawn about the present protection standards and the application of the methods to other fields of risk assessment. (author)

  14. Radiation protection standards: A practical exercise in risk assessment

    International Nuclear Information System (INIS)

    Clarke, Roger H.

    1992-01-01

    Within 12 months of the discovery of x-rays in 1895, it was reported that large doses of radiation were harmful to living human tissues. The first radiation protection standards were set to avoid the early effects of acute irradiation. By the 1950s, evidence was mounting for late somatic effects - mainly a small excess of cancers - in irradiated populations. In the late 1980's, sufficient human epidemiological data had been accumulated to allow a comprehensive assessment of carcinogenic radiation risks following the delivery of moderately high doses. Workers and the public are exposed to lower doses and dose-rates than the groups from whom good data are available so that risks have had to be estimated for protection purposes. However, in the 1990s, some confirmation of these risk factors has been derived occupationally exposed populations. If an estimate is made of the risk per unit dose, then in order to set dose limits, an unacceptable level of risk must be established for both workers and the public. There has been and continues to be a debate about the definitions of 'acceptable' and 'tolerable' and the attributing of numerical values to these definitions. This paper discusses the issues involved in the quantification of these terms and their application to setting dose limits on risk grounds. Conclusions are drawn about the present protection standards and the application of the methods to other fields of risk assessment. (author)

  15. Draft CSA standard on environmental risk assessments at class I nuclear facilities and uranium mines and mills

    International Nuclear Information System (INIS)

    Hart, D.; Garisto, N.; Parker, R.; Kovacs, R.; Thompson, B.

    2012-01-01

    The Canadian Standards Association (CSA) is preparing a draft Standard on environmental risk assessments (ERAs) at Class I nuclear facilities and uranium mines and mills (CSA N288.6). It is being prepared by a technical subcommittee of the CSA N288 Technical Committee, including experts from across the nuclear industry, government and regulatory authorities, and environmental service providers, among others. It addresses the design, implementation, and management of environmental risk assessment programs, and is intended to standardize practice across the industry. This paper outlines the scope of the draft Standard and highlights key features. It is under development and subject to change. (author)

  16. Critical Assessment of the Foundations of Power Transmission and Distribution Reliability Metrics and Standards.

    Science.gov (United States)

    Nateghi, Roshanak; Guikema, Seth D; Wu, Yue Grace; Bruss, C Bayan

    2016-01-01

    The U.S. federal government regulates the reliability of bulk power systems, while the reliability of power distribution systems is regulated at a state level. In this article, we review the history of regulating electric service reliability and study the existing reliability metrics, indices, and standards for power transmission and distribution networks. We assess the foundations of the reliability standards and metrics, discuss how they are applied to outages caused by large exogenous disturbances such as natural disasters, and investigate whether the standards adequately internalize the impacts of these events. Our reflections shed light on how existing standards conceptualize reliability, question the basis for treating large-scale hazard-induced outages differently from normal daily outages, and discuss whether this conceptualization maps well onto customer expectations. We show that the risk indices for transmission systems used in regulating power system reliability do not adequately capture the risks that transmission systems are prone to, particularly when it comes to low-probability high-impact events. We also point out several shortcomings associated with the way in which regulators require utilities to calculate and report distribution system reliability indices. We offer several recommendations for improving the conceptualization of reliability metrics and standards. We conclude that while the approaches taken in reliability standards have made considerable advances in enhancing the reliability of power systems and may be logical from a utility perspective during normal operation, existing standards do not provide a sufficient incentive structure for the utilities to adequately ensure high levels of reliability for end-users, particularly during large-scale events. © 2015 Society for Risk Analysis.

  17. Savannah River Site peer evaluator standards: Operator assessment for restart

    International Nuclear Information System (INIS)

    1990-01-01

    Savannah River Site has implemented a Peer Evaluator program for the assessment of certified Central Control Room Operators, Central Control Room Supervisors and Shift Technical Engineers prior to restart. This program is modeled after the nuclear Regulatory Commission's (NRC's) Examiner Standard, ES-601, for the requalification of licensed operators in the commercial utility industry. It has been tailored to reflect the unique differences between Savannah River production reactors and commercial power reactors

  18. Subjective Video Quality Assessment in H.264/AVC Video Coding Standard

    Directory of Open Access Journals (Sweden)

    Z. Miličević

    2012-11-01

    Full Text Available This paper seeks to provide an approach for subjective video quality assessment in the H.264/AVC standard. For this purpose a special software program for the subjective assessment of quality of all the tested video sequences is developed. It was developed in accordance with recommendation ITU-T P.910, since it is suitable for the testing of multimedia applications. The obtained results show that in the proposed selective intra prediction and optimized inter prediction algorithm there is a small difference in picture quality (signal-to-noise ratio between decoded original and modified video sequences.

  19. Health risk assessment standards of cyanobacteria bloom occurrence in bathing sites

    Directory of Open Access Journals (Sweden)

    Agnieszka Stankiewicz

    2011-03-01

    Full Text Available Threat for human health appears during a massive cyanobacteria bloom in potable water used for human consumption or in basins used for recreational purposes. General health risk assessment standards and preventive measures to be taken by sanitation service were presented in scope of: – evaluation of cyanobacteria bloom occurrence in bathing sites / water bodies, – procedures in case of cyanobacteria bloom, including health risk assessment and decision making process to protect users’ health at bathing sites, – preventive measures, to be taken in case of cyanobacteria bloom occurrence in bathing sites and basins, where bathing sites are located.

  20. Radiological assessments, environmental monitoring, and study design

    International Nuclear Information System (INIS)

    Hansen, W.R.; Elle, D.R.

    1980-01-01

    Studies of the behavior of transuranic elements in the environment form the basic data for applied programs in radiological assessment, environmental monitoring, derivation of radiation-protection standards, and environmental impact statements. This chapter introduces some of the major information requirements of these applications of transuranic research data. Characteristics of the source terms from nuclear activities usually are needed for an analysis of environmental pathways or deployment of monitoring systems. Major inhalation and ingestion pathways are considered in assessments of hazards from transuranics and are discussed from the viewpoint of research needed

  1. Standardization Study of Antifertility Drug - Pippalyadiyoga

    Directory of Open Access Journals (Sweden)

    D. Shaila

    2005-01-01

    Full Text Available The present paper deals with the standardization study of pippalyadiyoga powder. It is used as a long acting contraceptive. The standardization of compound drug has been achieved by physico-chemical analysis and high performance liquid chromatography (HPLC fingerprint studies. Quantitative evaluation of borax in pippalyadiyoga showed 19.08% as sodium borate. RP-HPLC was performed using methanol and water as mobile phase. The detection and quantification was performed at a wavelength of 345 nm. Linearity of detector response for piperine was between the concentrations 0.005% to 0.1%. The correlation coefficient obtained for the linearity was 0.998. The recovery value of standard piperine was 99.4%. Low value of standard deviation and coefficient of variation are indicative of high precision of the method. Quantitative evaluation of piperine in pippalyadiyoga was found to be 0.339%.

  2. Adherence of pain assessment to the German national standard for pain management in 12 nursing homes

    OpenAIRE

    Osterbrink, Jürgen; Bauer, Zsuzsa; Mitterlehner, Barbara; Gnass, Irmela; Kutschar, Patrick

    2014-01-01

    BACKGROUND: Pain is very common among nursing home residents. The assessment of pain is a prerequisite for effective multiprofessional pain management. Within the framework of the German health services research project, ‘Action Alliance Pain-Free City Muenster’, the authors investigated pain assessment adherence according to the German national Expert Standard for Pain Management in Nursing, which is a general standard applicable to all chronic/acute pain-affected persons and highly recommen...

  3. Standard deviation analysis of the mastoid fossa temperature differential reading: a potential model for objective chiropractic assessment.

    Science.gov (United States)

    Hart, John

    2011-03-01

    This study describes a model for statistically analyzing follow-up numeric-based chiropractic spinal assessments for an individual patient based on his or her own baseline. Ten mastoid fossa temperature differential readings (MFTD) obtained from a chiropractic patient were used in the study. The first eight readings served as baseline and were compared to post-adjustment readings. One of the two post-adjustment MFTD readings fell outside two standard deviations of the baseline mean and therefore theoretically represents improvement according to pattern analysis theory. This study showed how standard deviation analysis may be used to identify future outliers for an individual patient based on his or her own baseline data. Copyright © 2011 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  4. Study on residential appliances energy efficiency standards Refrigerators, air-conditioners, incandescent lamps, fluorescent lamps, color TVs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.G.; Cho, S.K.; Choi, S.H.; Jung, B.M.; Han, S.B.; Kim, K.D. [Korea Inst. of Energy Research, Taejon (Korea, Republic of)

    1995-12-01

    The energy efficiency standards and rating act, as amended by the rational energy utilization act, provides energy efficiency standards and ratings for 6 types of consumer products(refrigerators, air-conditioners, fluorescent lamps, incandescent lamps, ballasts and cars) authorizes the Ministry of Trade, Industry and Energy(MOTIE) to prescribe amended or new energy efficiency standards and rating standards. This study was initiated by the KIER in 1992. KIER`s assessment of the standards is designed to evaluate their statistical and engineering analysis according to Korean(Industrial) Standards(KS). And to make distinction between the poor efficiency and good efficiency models, 5 grades are classified depending on their tested energy efficiency. This year, based on our analysis, MOTIE mandated updated standards for refrigerators, air-conditioners, incandescent lamps, and fluorescent lamps. Also the objective of this study is to set the energy efficiency standards and to grade for color TV sets. (author). 37 refs., 89 figs., 85 tabs.

  5. Management system - correlation study between new IAEA standards and the market standards

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Dirceu Paulo de [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Ipero, SP (Brazil)], e-mail: dirceupo@hotmail.com; Zouain, Desiree Moraes [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: dmzouain@ipen.br

    2009-07-01

    In order to answer the growing concern of society with respect of the aspects that affect the quality of life, international and national regulatory bodies have developed standards that enable organizations to establish management systems for quality, environment and sustainable development, health, safety and social responsibility, among other functions. Within this context it is necessary to structure an integrated management system that promotes interests compatibility of several distinct and complementary functions involved. Considering this vision of the management system integration, the International Atomic Energy Agency (IAEA) decided to review the structure of safety standards on Quality Assurance - code and guides 50-C/SGQ1/ 14:1996, publishing, in 2006, IAEA GS-R-3 and IAEA GS-G-3.1 standards, enlarging the management approach of the previous standards, including the possibility of integrating the functions foremost mentioned. This paper presents the results about a correlation study between IAEA management system standards - IAEA GS-R-3: 2006, IAEA GS-G-3.1: 2006 and IAEA DS349 rev. 2007, this latter still a draft standard, with those market management system standards on quality - ISO 9001:2008, environmental - ISO 14001:2004, and occupational health and safety - BS OHSAS 18001:2007, identifying gaps, redundancies and complementarities among their requirements and guidances. The purpose of the study is to provide subsidies that could contribute to the structuring of a management system to nuclear facilities that satisfies, in an integrated manner, the common and complementary requirements and guidances of IAEA and market standards. (author)

  6. Management system - correlation study between new IAEA standards and the market standards

    International Nuclear Information System (INIS)

    Oliveira, Dirceu Paulo de; Zouain, Desiree Moraes

    2009-01-01

    In order to answer the growing concern of society with respect of the aspects that affect the quality of life, international and national regulatory bodies have developed standards that enable organizations to establish management systems for quality, environment and sustainable development, health, safety and social responsibility, among other functions. Within this context it is necessary to structure an integrated management system that promotes interests compatibility of several distinct and complementary functions involved. Considering this vision of the management system integration, the International Atomic Energy Agency (IAEA) decided to review the structure of safety standards on Quality Assurance - code and guides 50-C/SGQ1/ 14:1996, publishing, in 2006, IAEA GS-R-3 and IAEA GS-G-3.1 standards, enlarging the management approach of the previous standards, including the possibility of integrating the functions foremost mentioned. This paper presents the results about a correlation study between IAEA management system standards - IAEA GS-R-3: 2006, IAEA GS-G-3.1: 2006 and IAEA DS349 rev. 2007, this latter still a draft standard, with those market management system standards on quality - ISO 9001:2008, environmental - ISO 14001:2004, and occupational health and safety - BS OHSAS 18001:2007, identifying gaps, redundancies and complementarities among their requirements and guidances. The purpose of the study is to provide subsidies that could contribute to the structuring of a management system to nuclear facilities that satisfies, in an integrated manner, the common and complementary requirements and guidances of IAEA and market standards. (author)

  7. Pain assessment in patellar tendinopathy using pain pressure threshold algometry: : An observational study

    NARCIS (Netherlands)

    Kregel, Jeroen; van Wilgen, Cornelis Paul; Zwerver, Johannes

    ObjectiveAssessing pain in patellar tendinopathy (PT) is difficult to perform in a standardized way. With this study, we measured pain in athletes with PT by means of pain pressure threshold (PPT) algometry in a standardized manner. Subsequently, the goal of this study is to determine normative

  8. Adherence of Pain Assessment to the German National Standard for Pain Management in 12 Nursing Homes

    Directory of Open Access Journals (Sweden)

    Jürgen Osterbrink

    2014-01-01

    Full Text Available BACKGROUND: Pain is very common among nursing home residents. The assessment of pain is a prerequisite for effective multiprofessional pain management. Within the framework of the German health services research project, ‘Action Alliance Pain-Free City Muenster’, the authors investigated pain assessment adherence according to the German national Expert Standard for Pain Management in Nursing, which is a general standard applicable to all chronic/acute pain-affected persons and highly recommended for practice.

  9. Standardization of depression measurement

    DEFF Research Database (Denmark)

    Wahl, Inka; Löwe, Bernd; Bjørner, Jakob

    2014-01-01

    OBJECTIVES: To provide a standardized metric for the assessment of depression severity to enable comparability among results of established depression measures. STUDY DESIGN AND SETTING: A common metric for 11 depression questionnaires was developed applying item response theory (IRT) methods. Data...... of 33,844 adults were used for secondary analysis including routine assessments of 23,817 in- and outpatients with mental and/or medical conditions (46% with depressive disorders) and a general population sample of 10,027 randomly selected participants from three representative German household surveys....... RESULTS: A standardized metric for depression severity was defined by 143 items, and scores were normed to a general population mean of 50 (standard deviation = 10) for easy interpretability. It covers the entire range of depression severity assessed by established instruments. The metric allows...

  10. Using standardized video cases for assessment of medical communication skills: reliability of an objective structured video examination by computer

    NARCIS (Netherlands)

    Hulsman, R. L.; Mollema, E. D.; Oort, F. J.; Hoos, A. M.; de Haes, J. C. J. M.

    2006-01-01

    OBJECTIVE: Using standardized video cases in a computerized objective structured video examination (OSVE) aims to measure cognitive scripts underlying overt communication behavior by questions on knowledge, understanding and performance. In this study the reliability of the OSVE assessment is

  11. Guidelines, Criteria, and Rules of Thumb for Evaluating Normed and Standardized Assessment Instruments in Psychology.

    Science.gov (United States)

    Cicchetti, Domenic V.

    1994-01-01

    In the context of developing assessment instruments in psychology, issues of standardization, norming procedures, and test reliability and validity are discussed. Criteria, guidelines, and rules of thumb are provided to help the clinician with instrument selection for a given psychological assessment. (SLD)

  12. Teachers' use of a self-assessment procedure : the role of criteria, standards, feedback and reflection

    NARCIS (Netherlands)

    Diggelen, van M.R.; Brok, den P.J.; Beijaard, D.

    2013-01-01

    This article reports on the way teachers assess their own coaching competencies regarding the development of vocational education students’ reflection skills. The participating teachers used a self-assessment procedure in which they had to judge themselves with the help of criteria and standards,

  13. The EUR assessment process, methodology and highlights of the compliance analysis for the EU-APWR standard design - 15235

    International Nuclear Information System (INIS)

    Facciolo, L.; Welander, D.; Nuutinen, P.

    2015-01-01

    In August 2007 the European Utility Requirements organisation (EUR) received an initial application from Mitsubishi Heavy Industries asking for submitting the EU-APWR standard design to the EUR assessment. The EU-APWR is an advanced PWR, 1700 MWe class, 4-loops, 14 ft active core fuel length. The EU-APWR Standard Design documentation has been assessed against the EUR Volume 2 - Generic Nuclear Island requirements - Revision D. The assessment is divided into 20 chapters for a total of over 4000 individual requirements. A Synthesis Report for each chapter was written by the assessment performers. The Synthesis Reports showed that the EU-APWR Standard Design was in compliance with 77% of the EUR requirements. The percentage increases to 85% when taking into account the requirements where the design has been considered in compliance with the objectives. The requirements resulting in a non-compliance assessment correspond to less than 2%. This confirms the overall good level of compliance. From the Utilities point of view it is possible to state that the differences in standards, codes and regulations applied in Japan and in Europe contribute to a series of discrepancies between the EU-APWR Standard Design and the EUR, regarding, for instance, outage durations, operational capability, layout, personal protection or radiation monitoring. Some disagreements are easy to overcome, others require particular attention

  14. Assessment of hygiene standards and Hazard Analysis Critical Control Points implementation on passenger ships.

    Science.gov (United States)

    Mouchtouri, Varavara; Malissiova, Eleni; Zisis, Panagiotis; Paparizou, Evina; Hadjichristodoulou, Christos

    2013-01-01

    The level of hygiene on ferries can have impact on travellers' health. The aim of this study was to assess the hygiene standards of ferries in Greece and to investigate whether Hazard Analysis Critical Control Points (HACCP) implementation contributes to the hygiene status and particularly food safety aboard passenger ships. Hygiene inspections on 17 ferries in Greece were performed using a standardized inspection form, with a 135-point scale. Thirty-four water and 17 food samples were collected and analysed. About 65% (11/17) of ferries were scored with >100 points. Ferries with HACCP received higher scores during inspection compared to those without HACCP (p value food samples, only one was found positive for Salmonella spp. Implementation of management systems including HACCP principles can help to raise the level of hygiene aboard passenger ships.

  15. Nuclear standardization development study

    International Nuclear Information System (INIS)

    Pan Jianjun

    2010-01-01

    Nuclear industry is the important part of national security and national economic development is key area of national new energy supported by government. nuclear standardization is the important force for nuclear industry development, is the fundamental guarantee of nuclear safe production, is the valuable means of China's nuclear industry technology to the world market. Now nuclear standardization faces to the new development opportunity, nuclear standardization should implement strategy in standard system building, foreign standard research, company standard building, and talented people building to meet the requirement of nuclear industry development. (author)

  16. Comparison of INTERGROWTH-21 and Fenton growth standards to assess size at birth and extrauterine growth in very preterm infants.

    Science.gov (United States)

    Tuzun, Funda; Yucesoy, Ebru; Baysal, Bora; Kumral, Abdullah; Duman, Nuray; Ozkan, Hasan

    2018-09-01

    This study aimed to compare the recently published prescriptive INTERGROWTH-21st standards with commonly used intrauterine based Fenton growth standards in terms of birth size classification and extrauterine growth restriction (EUGR) incidence in a sample of very preterm infants. The anthropometric measures of preterm infants born before 32 weeks of gestation at the Dokuz Eylul University Hospital during the period from January 2012 to February 2016 were obtained at birth, at the 36th gestational weeks or at the time of discharge. Birth and growth data were presented as percentiles according to the two reference standards. A total of 248 infants with mean gestational age of 29.1 ± 2.1 weeks were included. The small for gestational age (SGA) rate was significantly higher (12 versus 15%, p = .004) and the EUGR rate was significantly lower (40.2 versus 31.5%, p Fentons'. Twenty-four per cent of the infants who were accepted as SGA according to the INTERGROWTH-21st standards were appropriate for gestational age (AGA) according to the Fenton preterm growth charts. However, these newly identified SGA infants according to the Intergrowth-21st standards did not have increased risks of early morbidities. Furthermore, 77% of the cases who had EUGR due to the Fenton standards were categorized as EUGR when evaluated using the INTERGROWTH-21st standards. Results indicated that almost one out of every five cases assessed as EUGR according to Fenton standards was within the normal interval according to Intergrowth standards. On the contrary, one out of every four cases assessed as SGA according to the INTERGROWTH-21st standards was within the normal interval according to Fentons'. These differences observed with INTERGROWTH-21st standards may affect in-hospital and postdischarge nutrition plan of these vulnerable infants. However, new standards are needed to be evaluated against currently used ones before they are implemented and further studies should be conducted

  17. Assessing the accuracy of forecasting: applying standard diagnostic assessment tools to a health technology early warning system.

    Science.gov (United States)

    Simpson, Sue; Hyde, Chris; Cook, Alison; Packer, Claire; Stevens, Andrew

    2004-01-01

    Early warning systems are an integral part of many health technology assessment programs. Despite this finding, to date, there have been no quantitative evaluations of the accuracy of predictions made by these systems. We report a study evaluating the accuracy of predictions made by the main United Kingdom early warning system. As prediction of impact is analogous to diagnosis, a method normally applied to determine the accuracy of diagnostic tests was used. The sensitivity, specificity, and predictive values of the National Horizon Scanning Centre's prediction methods were estimated with reference to an (imperfect) gold standard, that is, expert opinion of impact 3 to 5 years after prediction. The sensitivity of predictions was 71 percent (95 percent confidence interval [CI], 0.36-0.92), and the specificity was 73 percent (95 percent CI, 0.64-0.8). The negative predictive value was 98 percent (95 percent CI, 0.92-0.99), and the positive predictive value was 14 percent (95 percent CI, 0.06-0.3). Forecasting is difficult, but the results suggest that this early warning system's predictions have an acceptable level of accuracy. However, there are caveats. The first is that early warning systems may themselves reduce the impact of a technology, as helping to control adoption and diffusion is their main purpose. The second is that the use of an imperfect gold standard may bias the results. As early warning systems are viewed as an increasingly important component of health technology assessment and decision making, their outcomes must be evaluated. The method used here should be investigated further and the accuracy of other early warning systems explored.

  18. Introducing a design exigency to promote student learning through assessment: A case study.

    Science.gov (United States)

    Grealish, Laurie A; Shaw, Julie M

    2018-02-01

    Assessment technologies are often used to classify student and newly qualified nurse performance as 'pass' or 'fail', with little attention to how these decisions are achieved. Examining the design exigencies of classification technologies, such as performance assessment technologies, provides opportunities to explore flexibility and change in the process of using those technologies. Evaluate an established assessment technology for nursing performance as a classification system. A case study analysis that is focused on the assessment approach and a priori design exigencies of performance assessment technology, in this case the Australian Nursing Standards Assessment Tool 2016. Nurse assessors are required to draw upon their expertise to judge performance, but that judgement is described as a source of bias, creating confusion. The definition of satisfactory performance is 'ready to enter practice'. To pass, the performance on each criterion must be at least satisfactory, indicating to the student that no further improvement is required. The Australian Nursing Standards Assessment Tool 2016 does not have a third 'other' category, which is usually found in classification systems. Introducing a 'not yet competent' category and creating a two-part, mixed methods assessment process can improve the Australian Nursing Standards Assessment Tool 2016 assessment technology. Using a standards approach in the first part, judgement is valued and can generate learning opportunities across a program. Using a measurement approach in the second part, student performance can be 'not yet competent' but still meet criteria for year level performance and a graded pass. Subjecting the Australian Nursing Standards Assessment Tool 2016 assessment technology to analysis as a classification system provides opportunities for innovation in design. This design innovation has the potential to support students who move between programs and clinicians who assess students from different

  19. Developing standards for malaria microscopy: external competency assessment for malaria microscopists in the Asia-Pacific.

    Science.gov (United States)

    Ashraf, Sania; Kao, Angie; Hugo, Cecilia; Christophel, Eva M; Fatunmbi, Bayo; Luchavez, Jennifer; Lilley, Ken; Bell, David

    2012-10-24

    Malaria diagnosis has received renewed interest in recent years, associated with the increasing accessibility of accurate diagnosis through the introduction of rapid diagnostic tests and new World Health Organization guidelines recommending parasite-based diagnosis prior to anti-malarial therapy. However, light microscopy, established over 100 years ago and frequently considered the reference standard for clinical diagnosis, has been neglected in control programmes and in the malaria literature and evidence suggests field standards are commonly poor. Microscopy remains the most accessible method for parasite quantitation, for drug efficacy monitoring, and as a reference of assessing other diagnostic tools. This mismatch between quality and need highlights the importance of the establishment of reliable standards and procedures for assessing and assuring quality. This paper describes the development, function and impact of a multi-country microscopy external quality assurance network set up for this purpose in Asia. Surveys were used for key informants and past participants for feedback on the quality assurance programme. Competency scores for each country from 14 participating countries were compiled for analyses using paired sample t-tests. In-depth interviews were conducted with key informants including the programme facilitators and national level microscopists. External assessments and limited retraining through a formalized programme based on a reference slide bank has demonstrated an increase in standards of competence of senior microscopists over a relatively short period of time, at a potentially sustainable cost. The network involved in the programme now exceeds 14 countries in the Asia-Pacific, and the methods are extended to other regions. While the impact on national programmes varies, it has translated in some instances into a strengthening of national microscopy standards and offers a possibility both for supporting revival of national microcopy

  20. Developing standards for malaria microscopy: external competency assessment for malaria microscopists in the Asia-Pacific

    Directory of Open Access Journals (Sweden)

    Ashraf Sania

    2012-10-01

    Full Text Available Abstract Background Malaria diagnosis has received renewed interest in recent years, associated with the increasing accessibility of accurate diagnosis through the introduction of rapid diagnostic tests and new World Health Organization guidelines recommending parasite-based diagnosis prior to anti-malarial therapy. However, light microscopy, established over 100 years ago and frequently considered the reference standard for clinical diagnosis, has been neglected in control programmes and in the malaria literature and evidence suggests field standards are commonly poor. Microscopy remains the most accessible method for parasite quantitation, for drug efficacy monitoring, and as a reference of assessing other diagnostic tools. This mismatch between quality and need highlights the importance of the establishment of reliable standards and procedures for assessing and assuring quality. This paper describes the development, function and impact of a multi-country microscopy external quality assurance network set up for this purpose in Asia. Methods Surveys were used for key informants and past participants for feedback on the quality assurance programme. Competency scores for each country from 14 participating countries were compiled for analyses using paired sample t-tests. In-depth interviews were conducted with key informants including the programme facilitators and national level microscopists. Results External assessments and limited retraining through a formalized programme based on a reference slide bank has demonstrated an increase in standards of competence of senior microscopists over a relatively short period of time, at a potentially sustainable cost. The network involved in the programme now exceeds 14 countries in the Asia-Pacific, and the methods are extended to other regions. Conclusions While the impact on national programmes varies, it has translated in some instances into a strengthening of national microscopy standards and offers a

  1. California teachers' perceptions of standards-based reform in middle school science: A mixed-methods study

    Science.gov (United States)

    Leggett, Allison Gail Wilson

    The No Child Left Behind (NCLB) Act of 2001 presented one of the most significant and comprehensive literacy reforms in many years (McDonnell, 2005; U.S. Department of Education, 2006). The era of school accountability and standards based reform has brought many challenges and changes to public schools. Increasingly, public officials and educational administrators are asked to use standards based assessments to make high-stakes decisions, such as whether a student will move on to the next grade level or receive a diploma (American Psychological Association, 2005). It is important to understand any shifts in teachers' perceptions and to identify the changes teachers are making as they implement standards-based reform. This mixed-methods study was designed to assess teachers' perceptions of changes related to standards-based reform as supported by Fullan's (2001) change theory and transformational leadership theory. Survey questions sought to identify teacher perceptions of changes in curriculum, instruction and daily practice as schools documented and incorporated standards-based reform and began focusing on preparing students for the California Standards Test in Science (CSTS). Using descriptive statistical analysis and in-depth interviews, results show favorable insight towards standards-based reform. The survey was distributed to 30 middle school science teachers from 10 low-performing schools in Los Angeles, California. Results were analyzed using Spearman rank-ordered correlations. Interviews were conducted on middle school teachers represented by each grade level. Teachers who receive more support from administrators have more positive attitudes toward all aspects of SBR and the CSTS as measured in this study. No school should overlook the potential of a supportive administration in its effort to improve school programs.

  2. Study of federal microwave standards

    Energy Technology Data Exchange (ETDEWEB)

    David, L.

    1980-08-01

    Present and future federal regulatory processes which may impact the permissible levels of microwave radiation emitted by the SPS Microwave Power Transmission (MPTS) were studied. An historical development of US occupational and public microwave standards includes an overview of Western and East European philosophies of environmental protection and neurophysiology which have led to the current widely differing maximum permissible exposure limits to microwaves. The possible convergence of microwave standards is characterized by a lowering of Western exposure levels while Eastern countries consider standard relaxation. A trend toward stricter controls on activities perceived as harmful to public health is under way as is interest in improving the federal regulatory process. Particularly relevant to SPS is the initiation of long-term, low-level microwave exposure programs. Coupled with new developments in instrumentation and dosimetry, the results from chronic exposure program and population exposure studies could be expected within the next five to ten years. Also discussed is the increasing public concern that rf energy is yet another hazardous environmental agent.

  3. Characteristics of States' Alternate Assessments Based on Modified Academic Achievement Standards in 2008. Synthesis Report 72

    Science.gov (United States)

    Albus, Deb; Lazarus, Sheryl S.; Thurlow, Martha L.; Cormier, Damien

    2009-01-01

    In April 2007, Federal No Child Left Behind regulations were finalized that provided states with additional flexibility for assessing some students with disabilities. The regulations allowed states to offer another assessment option, alternate assessments based on modified academic achievement standards (AA-MAS). States are not required to have…

  4. Determination of Ergot Alkaloids: Purity and Stability Assessment of Standards and Optimization of Extraction Conditions for Cereal Samples

    DEFF Research Database (Denmark)

    Krska, R.; Berthiller, F.; Schuhmacher, R.

    2008-01-01

    as those that are the most common and physiologically active. The purity of the standards was investigated by means of liquid chromatography with diode array detection, electrospray ionization, and time-of-flight mass spectrometry (LC-DAD-ESI-TOF-MS). All of the standards assessed showed purity levels...... (PSA) before LC/MS/MS. Based on the results obtained from these optimization studies, a mixture of acetonitrile with ammonium carbonate buffer was used as extraction solvent, as recoveries for all analyzed ergot alkaloids were significantly higher than those with the other solvents. Different sample...

  5. Postnatal growth standards for preterm infants: the Preterm Postnatal Follow-up Study of the INTERGROWTH-21(st) Project.

    Science.gov (United States)

    Villar, José; Giuliani, Francesca; Bhutta, Zulfiqar A; Bertino, Enrico; Ohuma, Eric O; Ismail, Leila Cheikh; Barros, Fernando C; Altman, Douglas G; Victora, Cesar; Noble, Julia A; Gravett, Michael G; Purwar, Manorama; Pang, Ruyan; Lambert, Ann; Papageorghiou, Aris T; Ochieng, Roseline; Jaffer, Yasmin A; Kennedy, Stephen H

    2015-11-01

    Charts of size at birth are used to assess the postnatal growth of preterm babies on the assumption that extrauterine growth should mimic that in the uterus. The INTERGROWTH-21(st) Project assessed fetal, newborn, and postnatal growth in eight geographically defined populations, in which maternal health care and nutritional needs were met. From these populations, the Fetal Growth Longitudinal Study selected low-risk women starting antenatal care before 14 weeks' gestation and monitored fetal growth by ultrasonography. All preterm births from this cohort were eligible for the Preterm Postnatal Follow-up Study, which included standardised anthropometric measurements, feeding practices based on breastfeeding, and data on morbidity, treatments, and development. To construct the preterm postnatal growth standards, we selected all live singletons born between 26 and before 37 weeks' gestation without congenital malformations, fetal growth restriction, or severe postnatal morbidity. We did analyses with second-degree fractional polynomial regression models in a multilevel framework accounting for repeated measures. Fetal and neonatal data were pooled from study sites and stratified by postmenstrual age. For neonates, boys and girls were assessed separately. From 4607 women enrolled in the study, there were 224 preterm singleton births, of which 201 (90%) were enrolled in the Preterm Postnatal Follow-up Study. Variance component analysis showed that only 0·2% and 4·0% of the total variability in postnatal length and head circumference, respectively, could be attributed to between-site differences, justifying pooling the data from all study sites. Preterm growth patterns differed from those for babies in the INTERGROWTH-21(st) Newborn Size Standards. They overlapped with the WHO Child Growth Standards for term babies by 64 weeks' postmenstrual age. Our data have yielded standards for postnatal growth in preterm infants. These standards should be used for the assessment of

  6. STANDARD PRECAUTIONS: AN ASSESSMENT OF AWARENESS AMONG HEALTH CARE PERSONNEL IN A TEACHING HOSPITAL, SOUTH INDIA.

    Directory of Open Access Journals (Sweden)

    Sangeetha

    2015-02-01

    Full Text Available BACKGROUND : Standard precautions ar e crucial in the prevention and transmission of Healthcare associated infections ( HAI and transmission of blood - borne pathogens like Hepatitis B, Human Immunodeficiency Virus & Hepatitis C. They are not well u nderstood or implemented by health care practitioners. Hence this study was taken up to determine and compare knowledge, attitude of standard precautions among health care personnel at a teaching hospital, Bangalore. OBJECTIVE : To assess knowledge, attitud e, practices and compliance of Standard precautions among health care workers at a teaching hospital. METHODOLOGY : One hundred and fifty seven health care personnel participated in this study. A pretest and post test was administered to the study group. A pre - structured questionnaire on standard precautions was prepared which included knowledge, attitude and practices. RESULTS : 116 ( 73.88% nurses had knowledge about hand hygiene, but only 82 ( 52.2% nurses practiced hand hygiene before and after patient care. Knowledge about PPE measures like gloves, face mask & goggles, gowns were known to 101(64.33%, 56 ( 35.66% & 69 ( 43.94% nurses respectively. 117 ( 74.52% nurses discarded needles & sharps in correct puncture proof containers, but their correct knowled ge regarding colour coding of hospital waste segregation was comparatively less i.e. 104 ( 66.24%. 119 ( 75.79% of the nurses had practice of recapping the needles after use. CONCLUSION : There was significant improvement in the knowledge and practice of stan dard precautions in the present study after incorporating good training practices

  7. Phd study of reliability and validity: One step closer to a standardized music therapy assessment model

    DEFF Research Database (Denmark)

    Jacobsen, Stine Lindahl

    The paper will present a phd study concerning reliability and validity of music therapy assessment model “Assessment of Parenting Competences” (APC) in the area of families with emotionally neglected children. This study had a multiple strategy design with a philosophical base of critical realism...... and pragmatism. The fixed design for this study was a between and within groups design in testing the APCs reliability and validity. The two different groups were parents with neglected children and parents with non-neglected children. The flexible design had a multiple case study strategy specifically...

  8. Evaluation of the Standard Setting on the 2005 Grade 12 National Assessment of Educational Progress Mathematics Test

    Science.gov (United States)

    Sireci, Stephen G.; Hauger, Jeffrey B.; Wells, Craig S.; Shea, Christine; Zenisky, April L.

    2009-01-01

    The National Assessment Governing Board used a new method to set achievement level standards on the 2005 Grade 12 NAEP Math test. In this article, we summarize our independent evaluation of the process used to set these standards. The evaluation data included observations of the standard-setting meeting, observations of advisory committee meetings…

  9. Development of the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Timothy F.; Slater, S. J.

    2008-05-01

    Considerable effort in the astronomy education research (AER) community over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing the AER discipline so that researchers could establish the initial knowledge state of students as well as to attempt measure some of the impacts of innovative instructional interventions. Unfortunately, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. This was not done in oversight, but rather as a result of the relative youth of AER as a discipline. Now that several important science education reform documents exist and are generally accepted by the AER community, we are in a position to develop, validate, and disseminate a new assessment instrument which is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. In response, researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science & Math Teaching Center (UWYO SMTC) have designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for courses with learning goals tightly aligned to the consensus goals of our community.

  10. Scan-To Output Validation: Towards a Standardized Geometric Quality Assessment of Building Information Models Based on Point Clouds

    Science.gov (United States)

    Bonduel, M.; Bassier, M.; Vergauwen, M.; Pauwels, P.; Klein, R.

    2017-11-01

    The use of Building Information Modeling (BIM) for existing buildings based on point clouds is increasing. Standardized geometric quality assessment of the BIMs is needed to make them more reliable and thus reusable for future users. First, available literature on the subject is studied. Next, an initial proposal for a standardized geometric quality assessment is presented. Finally, this method is tested and evaluated with a case study. The number of specifications on BIM relating to existing buildings is limited. The Levels of Accuracy (LOA) specification of the USIBD provides definitions and suggestions regarding geometric model accuracy, but lacks a standardized assessment method. A deviation analysis is found to be dependent on (1) the used mathematical model, (2) the density of the point clouds and (3) the order of comparison. Results of the analysis can be graphical and numerical. An analysis on macro (building) and micro (BIM object) scale is necessary. On macro scale, the complete model is compared to the original point cloud and vice versa to get an overview of the general model quality. The graphical results show occluded zones and non-modeled objects respectively. Colored point clouds are derived from this analysis and integrated in the BIM. On micro scale, the relevant surface parts are extracted per BIM object and compared to the complete point cloud. Occluded zones are extracted based on a maximum deviation. What remains is classified according to the LOA specification. The numerical results are integrated in the BIM with the use of object parameters.

  11. Laterality and Lateralization in Autism Spectrum Disorder, Using a Standardized Neuro-Psychomotor Assessment.

    Science.gov (United States)

    Paquet, A; Golse, B; Girard, M; Olliac, B; Vaivre-Douret, L

    2017-01-01

    A detailed assessment of laterality in children with Autism Spectrum Disorder (ASD) was realized, including handedness and other measures (muscle tone, manual performance, dominant eye), using a standardized battery for the developmental assessment of neuro-psychomotor functions. The results of the laterality tests relating to cerebral hemisphere organization (spontaneous gestural laterality and tonic laterality) were different in ASD children, and indicate that the cerebral organization could be disrupted. These assessments, added to the observations of usual laterality most often reported in the literature, provide better understanding of the developmental organization from the pathophysiological point of view in children with ASD.

  12. Variation in Students' Conceptions of Self-Assessment and Standards

    Directory of Open Access Journals (Sweden)

    Heng Kiat Kelvin Tan

    2011-01-01

    Full Text Available This paper reports the results of a phenomenographic study on the different ways that secondary students understood and utilized student self-assessment and how various ego types could affect the accuracy of self-assessment. The study sought to contribute to the growing literature which recognizes the critical role that students play in assessment processes, and in particular the different roles that they assume in student self-assessment. The results of the study provide insights into how different students experience self-assessment by articulating the variation in the perception and purposes of assessing one's own learning. This variation is depicted as a hierarchy of logically related students' conceptions of self-assessment.

  13. The Role of Standardized Tests as a Means of Assessment of Young Children: A Review of Related Literature and Recommendations of Alternative Assessments for Administrators and Teachers.

    Science.gov (United States)

    Meadows, Stacie; Karr-Kidwell, P. J.

    An extensive review of literature related to the role of standardized tests in the assessment of young children was conducted, and recommendations were made for alternative approaches more appropriate to the assessment of young children. The first section of the paper contains a literature review that provides a brief history of standardized tests…

  14. Positive animal welfare states and reference standards for welfare assessment.

    Science.gov (United States)

    Mellor, D J

    2015-01-01

    Developments in affective neuroscience and behavioural science during the last 10-15 years have together made it increasingly apparent that sentient animals are potentially much more sensitive to their environmental and social circumstances than was previously thought to be the case. It therefore seems likely that both the range and magnitude of welfare trade-offs that occur when animals are managed for human purposes have been underestimated even when minimalistic but arguably well-intentioned attempts have been made to maintain high levels of welfare. In light of these neuroscience-supported behaviour-based insights, the present review considers the extent to which the use of currently available reference standards might draw attention to these previously neglected areas of concern. It is concluded that the natural living orientation cannot provide an all-embracing or definitive welfare benchmark because of its primary focus on behavioural freedom. However assessments of this type, supported by neuroscience insights into behavioural motivation, may now carry greater weight when used to identify management practices that should be avoided, discontinued or substantially modified. Using currently accepted baseline standards as welfare reference points may result in small changes being accorded greater significance than would be the case if they were compared with higher standards, and this could slow the progress towards better levels of welfare. On the other hand, using "what animals want" as a reference standard has the appeal of focusing on the specific resources or conditions the animals would choose themselves and can potentially improve their welfare more quickly than the approach of making small increments above baseline standards. It is concluded that the cautious use of these approaches in different combinations could lead to recommendations that would more effectively promote positive welfare states in hitherto neglected areas of concern.

  15. Writing to the Common Core: Teachers' Responses to Changes in Standards and Assessments for Writing in Elementary Schools

    Science.gov (United States)

    Wilcox, Kristen Campbell; Jeffery, Jill V.; Gardner-Bixler, Andrea

    2016-01-01

    This multiple case study investigated how the Common Core State Standards (CCSS) for writing and teacher evaluation system based in part on CCSS assessments might be influencing writing instruction in elementary schools. The sample included nine schools: Six achieved above-predicted performance on English Language Arts (ELA) as well as prior ELA…

  16. Using standardized patients to assess communication skills in medical and nursing students.

    Science.gov (United States)

    Ryan, C Anthony; Walshe, Nuala; Gaffney, Robert; Shanks, Andrew; Burgoyne, Louise; Wiskin, Connie M

    2010-03-17

    A number of recent developments in medical and nursing education have highlighted the importance of communication and consultation skills (CCS). Although such skills are taught in all medical and nursing undergraduate curriculums, there is no comprehensive screening or assessment programme of CCS using professionally trained Standardized Patients Educators (SPE's) in Ireland. This study was designed to test the content, process and acceptability of a screening programme in CCS with Irish medical and nursing students using trained SPE's and a previously validated global rating scale for CCS. Eight tutors from the Schools of Nursing and Medicine at University College Cork were trained in the use of a validated communication skills and attitudes holistic assessment tool. A total of forty six medical students (Year 2 of 5) and sixty four nursing students (Year 2/3 of 4) were selected to under go individual CCS assessment by the tutors via an SPE led scenario. Immediate formative feedback was provided by the SPE's for the students. Students who did not pass the assessment were referred for remediation CCS learning. Almost three quarters of medical students (33/46; 72%) and 81% of nursing students (56/64) passed the CCS assessment in both communication and attitudes categories. All nursing students had English as their first language. Nine of thirteen medical students referred for enhanced learning in CCS did not have English as their first language. A significant proportion of both medical and nursing students required referral for enhanced training in CCS. Medical students requiring enhanced training were more likely not to have English as a first language.

  17. Teachers' Use of a Self-Assessment Procedure: The Role of Criteria, Standards, Feedback and Reflection

    Science.gov (United States)

    van Diggelen, Migchiel; den Brok, Perry; Beijaard, Douwe

    2013-01-01

    This article reports on the way teachers assess their own coaching competencies regarding the development of vocational education students' reflection skills. The participating teachers used a self-assessment procedure in which they had to judge themselves with the help of criteria and standards, received feedback from a colleague based on the…

  18. First Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-01-01

    Considerable effort in the astronomy education research over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing astronomy as a sub-discipline of physics education research, allowing researchers to establish the initial knowledge state of students as well as to attempt to measure some of the impacts of innovative instructional interventions. Before now, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. Moving beyond the 10-year old Astronomy Diagnostics Test, we have developed and validated a new assessment instrument that is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this multiple-choice instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  19. Adopting HLA standard for interdependency study

    International Nuclear Information System (INIS)

    Nan, Cen; Eusgeld, Irene

    2011-01-01

    In recent decades, modern Critical Infrastructure (CI) has become increasingly automated and interlinked as more and more resources and information are required to maintain its day-to-day operation. A system failure, or even just a service debilitation, of any CI may have significant adverse effects on other infrastructures it is connected/interconnected with. It is vital to study the interdependencies within and between CIs and provide advanced modeling and simulation techniques in order to prevent or at least minimize these adverse effects. The key limitation of traditional mathematical models such as complex network theory is their lacking the capabilities of providing sufficient insights into interrelationships between CIs due to the complexities of these systems. A comprehensive method, a hybrid approach combining various modeling/simulation techniques in a distributed simulation environment, is presented in this paper. High Level Architecture (HLA) is an open standard (IEEE standard 1516) supporting simulations composed of different simulation components, which can be regarded as the framework for implementing such a hybrid approach. The concept of adopting HLA standard for the interdependency study is still under discussion by many researchers. Whether or not this HLA standard, or even the distributed simulation environment, is able to meet desired model/simulation requirements needs to be carefully examined. This paper presents the results from our experimental test-bed, which recreates the architecture of a typical Electricity Power Supply System (EPSS) with its own Supervisory Control and Data Acquisition (SCADA) system, for the purpose of investigating the capabilities of the HLA technique as a standard to perform interdependency studies.

  20. A probabilistic safety assessment of the standard French 900MWe pressurized water reactor. Main report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-04-15

    To situate the probabilistic safety assessment of standardized 900 MWe units made by the Institute for Nuclear Safety and Protection (IPSN), it is necessary to consider the importance and possible utilization of a study of this type. At the present time, the safety of nuclear installations essentially depends on the application of the defence in-depth approach. The design arrangements adopted are justified by the operating organization on the basis of deterministic studies of a limited number of conventional situations with corresponding safety margins. These conventional situations are grouped in categories by frequency, it being accepted that the greater the consequences the lesser the frequency must be. However in the framework of the analysis performed under the control of the French safety authority, the importance was rapidly recognized of setting an overall reference objective. By 1977, on the occasion of appraisal of the fundamental safety options of the standardized 1300 MWe units, the Central Service for the Safety of Nuclear Installations (SCSIN) set the following global probabilistic objective: 'Generally speaking, the design of installations including a pressurized water nuclear reactor must be such that the global probability of the nuclear unit being the origin of unacceptable consequences does not exceed 10{sup -6} per year...' Probabilistic analyses making reference to this global objective gradually began to supplement the deterministic approach, both for examining external hazards to be considered in the design basis and for examining the possible need for additional means of countering the failure of doubled systems in application of the deterministic single-failure criterion. A new step has been taken in France by carrying out two level 1 probabilistic safety assessments (calculation of the annual probability of core meltdown), one for the 900 MWe series by the IPSN and the other for the 1300 MWe series by Electricite de France. The objective

  1. A probabilistic safety assessment of the standard French 900MWe pressurized water reactor. Main report

    International Nuclear Information System (INIS)

    1990-04-01

    To situate the probabilistic safety assessment of standardized 900 MWe units made by the Institute for Nuclear Safety and Protection (IPSN), it is necessary to consider the importance and possible utilization of a study of this type. At the present time, the safety of nuclear installations essentially depends on the application of the defence in-depth approach. The design arrangements adopted are justified by the operating organization on the basis of deterministic studies of a limited number of conventional situations with corresponding safety margins. These conventional situations are grouped in categories by frequency, it being accepted that the greater the consequences the lesser the frequency must be. However in the framework of the analysis performed under the control of the French safety authority, the importance was rapidly recognized of setting an overall reference objective. By 1977, on the occasion of appraisal of the fundamental safety options of the standardized 1300 MWe units, the Central Service for the Safety of Nuclear Installations (SCSIN) set the following global probabilistic objective: 'Generally speaking, the design of installations including a pressurized water nuclear reactor must be such that the global probability of the nuclear unit being the origin of unacceptable consequences does not exceed 10 -6 per year...' Probabilistic analyses making reference to this global objective gradually began to supplement the deterministic approach, both for examining external hazards to be considered in the design basis and for examining the possible need for additional means of countering the failure of doubled systems in application of the deterministic single-failure criterion. A new step has been taken in France by carrying out two level 1 probabilistic safety assessments (calculation of the annual probability of core meltdown), one for the 900 MWe series by the IPSN and the other for the 1300 MWe series by Electricite de France. The objective of

  2. Assessing the Curricula of Political Sciences’ Programs at the Palestinian Universities in Accordance with the Academic Standards of Political Sciences

    Directory of Open Access Journals (Sweden)

    Alaa H. A . Aburedwan

    2017-11-01

    Full Text Available The study aimed at answering the following key question: Are academic standards of political sciences fulfilled in the curricula of political science programs at the Palestinian universities? Accordingly, the study included a theoretical section that explained the basic concepts of quality in education, and some international experiences adopted for quality assurance of political sciences programs. Then the study analyzed, according to the standard criteria, the curricula of four departments that grant a bachelor's degree in political sciences, based on information published on the departments’ sites on the internet, and according to the academic guidebook of each department. The study concluded that the mission and objectives of three departments are clear, while the findings of the analysis showed that there is mismatch of requirements in the Palestinian curricula with academic standards. Most programs are rich with major materials, but need a little adjustment to conform to the standards. The findings also showed a number of negative points in study plans, which do not contain enough credit hours for scientific research, computer applications, and field training, while they have extra credit hours for university requirements. The study made several recommendations to address the problems of the curricula, including: Inviting departments to form committees to ensure quality, to modify the curricula, and develop it in accordance with international standards. Keywords: Academic program, Academic standards, Curricula assessment, Political sciences.

  3. Qualitative Assessment of Ultrasound Biomicroscopic Images Using Standard Photographs: The Liwan Eye Study

    Science.gov (United States)

    Jiang, Yuzhen; Huang, Wenyong; Huang, Qunxiao; Zhang, Jian; Foster, Paul J.

    2010-01-01

    Objective. To classify anatomic features related to anterior chamber angles by a qualitative assessment system based on ultrasound biomicroscopy (UBM) images. Methods. Cases of primary angle-closure suspect (PACS), defined by pigmented trabecular meshwork that is not visible in two or more quadrants on static gonioscopy (cases) and systematically selected subjects (1 of every 10) who did not meet this criterion (controls) were enrolled during a population-based survey in Guangzhou, China. All subjects underwent UBM examination. A set of standard UBM images was used to qualitatively classify anatomic features related to the angle configuration, including iris thickness, iris convexity, iris angulation, ciliary body size, and ciliary process position. All analysis was conducted on right eye images. Results. Based on the qualitative grades, the difference in overall iris thickness between gonioscopically narrow eyes (n = 117) and control eyes (n = 57) was not statistically significant. The peripheral one third of the iris tended to be thicker in all quadrants of the PACS eyes, although the difference was statistically significant only in the superior quadrant (P = 0.008). No significant differences were found in the qualitative classifications of iris insertion, iris angulation, ciliary body size, and ciliary process position. The findings were similar when compared with the control group of eyes with wide angles in all quadrants. Conclusions. Basal iris thickness seems to be more relevant to narrow angle configuration than to overall iris thickness. Otherwise, the anterior rotation and size of the ciliary body, the iris insertion, and the overall iris thickness are comparable in narrow- and wide-angle eyes. PMID:19834039

  4. The role of framing effect in assessment of quality of life according to standard gambling theory

    Directory of Open Access Journals (Sweden)

    Songul Cinaroglu

    2015-08-01

    Full Text Available Measuring health outcomes includes risk and uncertainty. Quality of life assessment in health care has two main properties one is they are personal, the other is they are reflecting personal preferences. Because of patient preferences includes risk and uncertainty standard gambling theory used which is one of the quantitative techniques for assessment of patient preferences. Framing effect which is based on social psychology, shows that positive and negative framed information effects decision making. For this reason in this study we aim to discuss the role of framing effect on quality of life assessments when standart gambling theory was used. Results of this study show that compare to traditional framing effect, medical framework reveal opposite results. Patients show risk seeking behavior in positive framework and they show risk aversion behaviour in negative framework. We think that the results of this study provides useful information for understanding of how framing make a bias in asssessment of patient preferences. [TAF Prev Med Bull 2015; 14(4.000: 346-352

  5. Ar-40/Ar-39 Studies of Martian Meteorite RBT 04262 and Terrestrial Standards

    Science.gov (United States)

    Park, J.; Herzog, G. F.; Turrin, B.; Lindsay, F. N.; Delaney, J. S.; Swisher, C. C., III; Nagao, K.; Nyquist, L. E.

    2014-01-01

    Park et al. recently presented an Ar-40/Ar-39 dating study of maskelynite separated from the Martian meteorite RBT 04262. Here we report an additional study of Ar-40/Ar-39 patterns for smaller samples, each consisting of only a few maskelynite grains. Considered as a material for Ar-40/Ar-39 dating, the shock-produced glass maskelynite has both an important strength (relatively high K concentration compared to other mineral phases) and some potentially problematic weaknesses. At Rutgers, we have been analyzing small grains consisting of a single phase to explore local effects that might be averaged and remain hidden in larger samples. Thus, to assess the homogeneity of the RBT maskelynite and for comparison with the results of, we analyzed six approx. 30 microgram samples of the same maskelynite separate they studied. Furthermore, because most Ar-40/Ar-39 are calculated relative to the age of a standard, we present new Ar-40/Ar-39 age data for six standards. Among the most widely used standards are sanidine from Fish Canyon (FCs) and various hornblendes (hb3gr, MMhb-1, NL- 25), which are taken as primary standards because their ages have been determined by independent, direct measurements of K and A-40.

  6. OSHA's approach to risk assessment for setting a revised occupational exposure standard for 1,3-butadiene.

    Science.gov (United States)

    Grossman, E A; Martonik, J

    1990-01-01

    In its 1980 benzene decision [Industrial Union Department, ALF-CIO v. American Petroleum Institute, 448 U.S. 607 (1980)], the Supreme Court ruled that "before he can promulgate any permanent health or safety standard, the Secretary [of Labor] is required to make a threshold finding that a place of employment is unsafe--in the sense that significant risks are present and can be lessened by a change in practices" (448 U.S. at 642). The Occupational Safety and Health Administration (OSHA) has interpreted this to mean that whenever possible, it must quantify the risk associated with occupational exposure to a toxic substance at the current permissible exposure limit (PEL). If OSHA determines that there is significant risk to workers' health at its current standard, then it must quantify the risk associated with a variety of alternative standards to determine at what level, if any, occupational exposure to a substance no longer poses a significant risk. For rulemaking on occupational exposure to 1,3-butadiene, there are two studies that are suitable for quantitative risk assessment. One is a mouse inhalation bioassay conducted by the National Toxicology Program (NTP), and the other is a rat inhalation bioassay conducted by Hazelton Laboratories Europe. Of the four risk assessments that have been submitted to OSHA, all four have used the mouse and/or rat data with a variety of models to quantify the risk associated with occupational exposure to 1,3-butadiene. In addition, OSHA has performed its own risk assessment using the female mouse and female rat data and the one-hit and multistage models.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:2401254

  7. Dental Hygiene Faculty Calibration Using Two Accepted Standards for Calculus Detection: A Pilot Study.

    Science.gov (United States)

    Santiago, Lisa J; Freudenthal, Jacqueline J; Peterson, Teri; Bowen, Denise M

    2016-08-01

    Faculty calibration studies for calculus detection use two different standards for examiner evaluation, yet the only therapeutic modality that can be used for nonsurgical periodontal treatment is scaling/root debridement or planing. In this study, a pretest-posttest design was used to assess the feasibility of faculty calibration for calculus detection using two accepted standards: that established by the Central Regional Dental Testing Service, Inc. (CRDTS; readily detectible calculus) and the gold standard for scaling/root debridement (root roughness). Four clinical dental hygiene faculty members out of five possible participants at Halifax Community College agreed to participate. The participants explored calculus on the 16 assigned teeth (64 surfaces) of four patients. Calculus detection scores were calculated before and after training. Kappa averages using CRDTS criteria were 0.561 at pretest and 0.631 at posttest. Kappa scores using the scaling/root debridement or planing standard were 0.152 at pretest and 0.271 at posttest. The scores indicated improvement from moderate (Kappa=0.41-0.60) to substantial agreement (Kappa=0.61-0.80) following training using the CRDTS standard. Although this result differed qualitatively and Kappas were significantly different from 0, the differences for pre- to post-Kappas for patient-rater dyads using CRDTS were not statistically significant (p=0.778). There was no difference (p=0.913) in Kappa scores pre- to post-training using the scaling/root debridement standard. Despite the small number of participants in this study, the results indicated that training to improve interrater reliability to substantial agreement was feasible using the CRDTS standard but not using the gold standard. The difference may have been due to greater difficulty in attaining agreement regarding root roughness. Future studies should include multiple training sessions with patients using the same standard for scaling/root debridement used for

  8. 48 CFR 52.223-16 - IEEE 1680 Standard for the Environmental Assessment of Personal Computer Products.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false IEEE 1680 Standard for the... CONTRACT CLAUSES Text of Provisions and Clauses 52.223-16 IEEE 1680 Standard for the Environmental Assessment of Personal Computer Products. As prescribed in 23.706(b)(1), insert the following clause: IEEE...

  9. Contribution of diagnostic tests for the etiological assessment of uveitis, data from the ULISSE study (Uveitis: Clinical and medicoeconomic evaluation of a standardized strategy of the etiological diagnosis).

    Science.gov (United States)

    Grumet, Pierre; Kodjikian, Laurent; de Parisot, Audrey; Errera, Marie-Hélène; Sedira, Neila; Heron, Emmanuel; Pérard, Laurent; Cornut, Pierre-Loïc; Schneider, Christelle; Rivière, Sophie; Ollé, Priscille; Pugnet, Grégory; Cathébras, Pascal; Manoli, Pierre; Bodaghi, Bahram; Saadoun, David; Baillif, Stéphanie; Tieulie, Nathalie; Andre, Marc; Chiambaretta, Frédéric; Bonin, Nicolas; Bielefeld, Philip; Bron, Alain; Mouriaux, Frédéric; Bienvenu, Boris; Vicente, Stéphanie; Bin, Sylvie; Labetoulle, Marc; Broussolle, Christiane; Jamilloux, Yvan; Decullier, Evelyne; Sève, Pascal

    2018-04-01

    ULISSE is the only study that prospectively assessed the efficiency of a standardized strategy, compared to an open strategy for the etiologic diagnosis of uveitis. Our aim was to evaluate the diagnostic yield of the tests prescribed in the ULISSE study to clarify their relevance. ULISSE is a non-inferiority, prospective, multicenter and cluster randomized study. The standardized strategy is a two-steps strategy: in the first step, common standard tests were performed, and in the second step, tests were guided by the clinical and anatomic type of uveitis. We reported the relevance of the diagnostic tests used in the standardized strategy, as well as the profitability of the tests that were prescribed to more than twenty patients in each group. Based on diagnostic criteria, either an ophthalmologist, or an internist, established the profitability of a test by considering whether the test lead to a diagnosis or not. Among the 676 patients included (standardized 303; open 373), a diagnosis was made for 152 (50.4%) in the standardized group and 203 (54.4%) in the open group. The most common entities were HLA-B27 associated uveitis (22%), spondyloarthritis (11%), sarcoidosis (18%), tuberculosis (10.7%) and herpes virus infections (8.5%). Among the first step's systematic tests, tuberculin skin test was the most contributive investigation (17.1%), followed by chest X-ray (8.4%), C reactive protein and ESR (6.6% and 5.1%), complete blood count (2.2%) and VDRL (2.0%). The second step's most often contributive tests were: HLA B27 (56.3%), chest-CT (30.3%) and angiotensin converting enzyme (ACE) (16.5%). HLA B27 and ACE were significantly more contributive in the standardized group than in the open group. Immunological tests were never contributive. Among the free investigations, or among the investigations guided by clinical or paraclinical findings, the most often contributive tests were: Quantiferon® (24%), electrophoresis of serum protein (7.8%) and sacroiliac imagery

  10. Towards identifying dyslexia in Standard Indonesian: : the development of a reading assessment battery

    NARCIS (Netherlands)

    Jap, Bernard Amadeus Jaya; Borleffs, Elisabeth; Maassen, Bernardus

    2017-01-01

    With its transparent orthography, Standard Indonesian is spoken by over 160 million inhabitants and is the primary language of instruction in education and the government in Indonesia. An assessment battery of reading and reading-related skills was developed as a starting point for the diagnosis of

  11. Methodological Study to Develop Standard Operational Protocol on Oral Drug Administration for Children.

    Science.gov (United States)

    Bijarania, Sunil Kumar; Saini, Sushma Kumari; Verma, Sanjay; Kaur, Sukhwinder

    2017-05-01

    To develop standard operational protocol (SOP) on oral drug administration and checklist to assess the implementation of the developed SOP. In this prospective methodological study, SOPs were developed in five phases. In the first phase, the preliminary draft of SOPs and checklists were prepared based on literature review, assessment of current practices and focus group discussion (FGD) with bedside working nurses. In the second phase, content validity was checked with the help of Delphi technique (12 experts). Total four drafts were prepared in stages and necessary modifications were made as per suggestions after each Delphi round. Fourth Delphi round was performed after conducting a pilot study. In the fourth phase, all bedside nurses were trained as per SOPs and asked to practice accordingly and observation of thirty oral drug administrations in children was done to check reliability of checklists for implementation of SOPs. In Phase-V, 7 FGDs were conducted with bedside nurses to assess the effectiveness of SOPs. The Content Validity Index (CVI) of SOP and checklists was 99.77%. Overall standardized Cronbach's alpha was calculated as 0.94. All the nurses felt that the SOP is useful. Valid and feasible SOP for drug administration to children through oral route along with valid and reliable checklist were developed. It is recommended to use this document for drug administration to children.

  12. Environmental assessment in support of proposed voluntary energy conservation standard for new residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hadley, D.L.; Parker, G.B.; Callaway, J.W.; Marsh, S.J.; Roop, J.M.; Taylor, Z.T.

    1989-06-01

    The objective of this environmental assessment (EA) is to identify the potential environmental impacts that could result from the proposed voluntary residential standard (VOLRES) on private sector construction of new residential buildings. 49 refs., 15 tabs.

  13. Integrated FDG-PET/CT vs. standard radiological examinations: Comparison of capability for assessment of postoperative recurrence in non-small cell lung cancer patients

    International Nuclear Information System (INIS)

    Takenaka, Daisuke; Ohno, Yoshiharu; Koyama, Hisanobu; Nogami, Munenobu; Onishi, Yumiko; Matsumoto, Keiko; Matsumoto, Sumiaki; Yoshikawa, Takeshi; Sugimura, Kazuro

    2010-01-01

    Purpose: The purpose of this study was to prospectively and directly compare diagnostic capabilities of whole-body integrated FDG-PET/CT and standard radiologic examination for assessment of recurrence in postoperative non-small cell lung cancer (NSCLC) patients. Materials and methods: A total of 92 consecutive pathologically diagnosed NSCLC patients (65 males, 27 females; mean age, 71 years) underwent pathologically and surgically proven complete resection, followed by prospective whole-body FDG-PET/CT and standard radiological examinations. Final diagnosis of recurrence was based on the results of more than 1 year of follow-up and/or pathological examinations. On both methods, the probability of recurrence was assessed in each patient by using a five-point visual scoring system, and the each final diagnosis was made by consensus between two readers. Kappa analyses were performed to determine inter-observer agreement for both methods, and ROC analyses were used to compare capability of the two methods for assessment of postoperative recurrence on a per-patient basis. Sensitivity, specificity and accuracy were also compared between PET/CT and standard radiological examination by means of McNemar's test. Results: All inter-observer agreements were almost perfect (integrated PET/CT: κ = 0.89; standard radiological examination: κ = 0.81). There were no statistically significant differences in area under the curve, sensitivity, specificity and accuracy between integrated FDG-PET/CT and standard radiologic examinations (p > 0.05). Conclusion: Integrated FDG-PET/CT can be used for assessment of postoperative recurrence in NSCLC patients with accuracy as good as that of standard radiological examinations.

  14. Integrated FDG-PET/CT vs. standard radiological examinations: Comparison of capability for assessment of postoperative recurrence in non-small cell lung cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Takenaka, Daisuke [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.j [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Koyama, Hisanobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Nogami, Munenobu [Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, 2-2, Minatojima Minamimachi Chuo-ku, Kobe, Hyogo 650-0047 (Japan); Onishi, Yumiko; Matsumoto, Keiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Matsumoto, Sumiaki [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Department of Radiology, University of Yamanashi, 1110 Shimogato, Chuo, Yamanashi, 409-3898 (Japan); Yoshikawa, Takeshi; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan)

    2010-06-15

    Purpose: The purpose of this study was to prospectively and directly compare diagnostic capabilities of whole-body integrated FDG-PET/CT and standard radiologic examination for assessment of recurrence in postoperative non-small cell lung cancer (NSCLC) patients. Materials and methods: A total of 92 consecutive pathologically diagnosed NSCLC patients (65 males, 27 females; mean age, 71 years) underwent pathologically and surgically proven complete resection, followed by prospective whole-body FDG-PET/CT and standard radiological examinations. Final diagnosis of recurrence was based on the results of more than 1 year of follow-up and/or pathological examinations. On both methods, the probability of recurrence was assessed in each patient by using a five-point visual scoring system, and the each final diagnosis was made by consensus between two readers. Kappa analyses were performed to determine inter-observer agreement for both methods, and ROC analyses were used to compare capability of the two methods for assessment of postoperative recurrence on a per-patient basis. Sensitivity, specificity and accuracy were also compared between PET/CT and standard radiological examination by means of McNemar's test. Results: All inter-observer agreements were almost perfect (integrated PET/CT: {kappa} = 0.89; standard radiological examination: {kappa} = 0.81). There were no statistically significant differences in area under the curve, sensitivity, specificity and accuracy between integrated FDG-PET/CT and standard radiologic examinations (p > 0.05). Conclusion: Integrated FDG-PET/CT can be used for assessment of postoperative recurrence in NSCLC patients with accuracy as good as that of standard radiological examinations.

  15. Current Methods Applied to Biomaterials - Characterization Approaches, Safety Assessment and Biological International Standards.

    Science.gov (United States)

    Oliveira, Justine P R; Ortiz, H Ivan Melendez; Bucio, Emilio; Alves, Patricia Terra; Lima, Mayara Ingrid Sousa; Goulart, Luiz Ricardo; Mathor, Monica B; Varca, Gustavo H C; Lugao, Ademar B

    2018-04-10

    Safety and biocompatibility assessment of biomaterials are themes of constant concern as advanced materials enter the market as well as products manufactured by new techniques emerge. Within this context, this review provides an up-to-date approach on current methods for the characterization and safety assessment of biomaterials and biomedical devices from a physicalchemical to a biological perspective, including a description of the alternative methods in accordance with current and established international standards. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  16. Protocol of the COSMIN study: COnsensus-based Standards for the selection of health Measurement INstruments

    Directory of Open Access Journals (Sweden)

    Patrick DL

    2006-01-01

    Full Text Available Abstract Background Choosing an adequate measurement instrument depends on the proposed use of the instrument, the concept to be measured, the measurement properties (e.g. internal consistency, reproducibility, content and construct validity, responsiveness, and interpretability, the requirements, the burden for subjects, and costs of the available instruments. As far as measurement properties are concerned, there are no sufficiently specific standards for the evaluation of measurement properties of instruments to measure health status, and also no explicit criteria for what constitutes good measurement properties. In this paper we describe the protocol for the COSMIN study, the objective of which is to develop a checklist that contains COnsensus-based Standards for the selection of health Measurement INstruments, including explicit criteria for satisfying these standards. We will focus on evaluative health related patient-reported outcomes (HR-PROs, i.e. patient-reported health measurement instruments used in a longitudinal design as an outcome measure, excluding health care related PROs, such as satisfaction with care or adherence. The COSMIN standards will be made available in the form of an easily applicable checklist. Method An international Delphi study will be performed to reach consensus on which and how measurement properties should be assessed, and on criteria for good measurement properties. Two sources of input will be used for the Delphi study: (1 a systematic review of properties, standards and criteria of measurement properties found in systematic reviews of measurement instruments, and (2 an additional literature search of methodological articles presenting a comprehensive checklist of standards and criteria. The Delphi study will consist of four (written Delphi rounds, with approximately 30 expert panel members with different backgrounds in clinical medicine, biostatistics, psychology, and epidemiology. The final checklist will

  17. Using standardized patients to assess communication skills in medical and nursing students

    LENUS (Irish Health Repository)

    Ryan, C Anthony

    2010-03-17

    Abstract Background A number of recent developments in medical and nursing education have highlighted the importance of communication and consultation skills (CCS). Although such skills are taught in all medical and nursing undergraduate curriculums, there is no comprehensive screening or assessment programme of CCS using professionally trained Standardized Patients Educators (SPE\\'s) in Ireland. This study was designed to test the content, process and acceptability of a screening programme in CCS with Irish medical and nursing students using trained SPE\\'s and a previously validated global rating scale for CCS. Methods Eight tutors from the Schools of Nursing and Medicine at University College Cork were trained in the use of a validated communication skills and attitudes holistic assessment tool. A total of forty six medical students (Year 2 of 5) and sixty four nursing students (Year 2\\/3 of 4) were selected to under go individual CCS assessment by the tutors via an SPE led scenario. Immediate formative feedback was provided by the SPE\\'s for the students. Students who did not pass the assessment were referred for remediation CCS learning. Results Almost three quarters of medical students (33\\/46; 72%) and 81% of nursing students (56\\/64) passed the CCS assessment in both communication and attitudes categories. All nursing students had English as their first language. Nine of thirteen medical students referred for enhanced learning in CCS did not have English as their first language. Conclusions A significant proportion of both medical and nursing students required referral for enhanced training in CCS. Medical students requiring enhanced training were more likely not to have English as a first language.

  18. Using standardized patients to assess communication skills in medical and nursing Students

    Directory of Open Access Journals (Sweden)

    Burgoyne Louise

    2010-03-01

    Full Text Available Abstract Background A number of recent developments in medical and nursing education have highlighted the importance of communication and consultation skills (CCS. Although such skills are taught in all medical and nursing undergraduate curriculums, there is no comprehensive screening or assessment programme of CCS using professionally trained Standardized Patients Educators (SPE's in Ireland. This study was designed to test the content, process and acceptability of a screening programme in CCS with Irish medical and nursing students using trained SPE's and a previously validated global rating scale for CCS. Methods Eight tutors from the Schools of Nursing and Medicine at University College Cork were trained in the use of a validated communication skills and attitudes holistic assessment tool. A total of forty six medical students (Year 2 of 5 and sixty four nursing students (Year 2/3 of 4 were selected to under go individual CCS assessment by the tutors via an SPE led scenario. Immediate formative feedback was provided by the SPE's for the students. Students who did not pass the assessment were referred for remediation CCS learning. Results Almost three quarters of medical students (33/46; 72% and 81% of nursing students (56/64 passed the CCS assessment in both communication and attitudes categories. All nursing students had English as their first language. Nine of thirteen medical students referred for enhanced learning in CCS did not have English as their first language. Conclusions A significant proportion of both medical and nursing students required referral for enhanced training in CCS. Medical students requiring enhanced training were more likely not to have English as a first language.

  19. A standardized approach to study human variability in isometric thermogenesis during low-intensity physical activity

    Directory of Open Access Journals (Sweden)

    Delphine eSarafian

    2013-07-01

    Full Text Available Limitations of current methods: The assessment of human variability in various compartments of daily energy expenditure (EE under standardized conditions is well defined at rest (as basal metabolic rate and thermic effect of feeding, and currently under validation for assessing the energy cost of low-intensity dynamic work. However, because physical activities of daily life consist of a combination of both dynamic and isometric work, there is also a need to develop standardized tests for assessing human variability in the energy cost of low-intensity isometric work.Experimental objectives: Development of an approach to study human variability in isometric thermogenesis by incorporating a protocol of intermittent leg press exercise of varying low-intensity isometric loads with measurements of EE by indirect calorimetry. Results: EE was measured in the seated position with the subject at rest or while intermittently pressing both legs against a press-platform at 5 low-intensity isometric loads (+5, +10, + 15, +20 and +25 kg force, each consisting of a succession of 8 cycles of press (30 s and rest (30 s. EE, integrated over each 8-min period of the intermittent leg press exercise, was found to increase linearly across the 5 isometric loads with a correlation coefficient (r > 0.9 for each individual. The slope of this EE-Load relationship, which provides the energy cost of this standardized isometric exercise expressed per kg force applied intermittently (30 s in every min, was found to show good repeatability when assessed in subjects who repeated the same experimental protocol on 3 separate days: its low intra-individual coefficient of variation (CV of ~ 10% contrasted with its much higher inter-individual CV of 35%; the latter being mass-independent but partly explained by height. Conclusion: This standardized approach to study isometric thermogenesis opens up a new avenue for research in EE phenotyping and metabolic predisposition to obesity

  20. Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization

    OpenAIRE

    Lodge, Martin A; Holt, Daniel P; Kinahan, Paul E; Wong, Dean F; Wahl, Richard L

    2015-01-01

    Background Although NaI(Tl) gamma counters play an important role in many quantitative positron emission tomography (PET) protocols, their calibration for positron-emitting samples has not been standardized across imaging sites. In this study, we characterized the operational range of a gamma counter specifically for positron-emitting radionuclides, and we assessed the role of traceable 68Ge/68Ga sources for standardizing system calibration. Methods A NaI(Tl) gamma counter was characterized w...

  1. Assessing validity of a depression screening instrument in the absence of a gold standard.

    Science.gov (United States)

    Gelaye, Bizu; Tadesse, Mahlet G; Williams, Michelle A; Fann, Jesse R; Vander Stoep, Ann; Andrew Zhou, Xiao-Hua

    2014-07-01

    We evaluated the extent to which use of a hypothesized imperfect gold standard, the Composite International Diagnostic Interview (CIDI), biases the estimates of diagnostic accuracy of the Patient Health Questionnaire-9 (PHQ-9). We also evaluate how statistical correction can be used to address this bias. The study was conducted among 926 adults where structured interviews were conducted to collect information about participants' current major depressive disorder using PHQ-9 and CIDI instruments. First, we evaluated the relative psychometric properties of PHQ-9 using CIDI as a gold standard. Next, we used a Bayesian latent class model to correct for the bias. In comparison with CIDI, the relative sensitivity and specificity of the PHQ-9 for detecting major depressive disorder at a cut point of 10 or more were 53.1% (95% confidence interval: 45.4%-60.8%) and 77.5% (95% confidence interval, 74.5%-80.5%), respectively. Using a Bayesian latent class model to correct for the bias arising from the use of an imperfect gold standard increased the sensitivity and specificity of PHQ-9 to 79.8% (95% Bayesian credible interval, 64.9%-90.8%) and 79.1% (95% Bayesian credible interval, 74.7%-83.7%), respectively. Our results provided evidence that assessing diagnostic validity of mental health screening instrument, where application of a gold standard might not be available, can be accomplished by using appropriate statistical methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Assessing changes in drought characteristics with standardized indices

    Science.gov (United States)

    Vidal, Jean-Philippe; Najac, Julien; Martin, Eric; Franchistéguy, Laurent; Soubeyroux, Jean-Michel

    2010-05-01

    Standardized drought indices like the Standardized Precipitation Index (SPI) are more and more frequently adopted for drought reconstruction, monitoring and forecasting, and the SPI has been recently recommended by the World Meteorological Organization to characterize meteorological droughts. Such indices are based on the statistical distribution of a hydrometeorological variable (e.g., precipitation) in a given reference climate, and a drought event is defined as a period with continuously negative index values. Because of the way these indices are constructed, some issues may arise when using them in a non-stationnary climate. This work thus aims at highlighting such issues and demonstrating the different ways these indices may - or may not - be applied and interpreted in the context of an anthropogenic climate change. Three major points are detailed through examples taken from both a high-resolution gridded reanalysis dataset over France and transient projections from the ARPEGE general circulation model downscaled over France. The first point deals with the choice of the reference climate, and more specifically its type (from observations/reanalysis or from present-day modelled climate) and its record period. Second, the interpretation of actual changes are closely linked with the type of the selected drought feature over a future period: mean index value, under-threshold frequency, or drought event characteristics (number, mean duration and magnitude, seasonality, etc.). Finally, applicable approaches as well as related uncertainties depend on the availability of data from a future climate, whether in the form of a fully transient time series from present-day or only a future time slice. The projected evolution of drought characteristics under climate change must inform present decisions on long-term water resources planning. An assessment of changes in drought characteristics should therefore provide water managers with appropriate information that can help

  3. Assessing Resilience in Students Who Are Deaf or Blind: Supplementing Standardized Achievement Testing

    Science.gov (United States)

    Butler, Michelle A.; Katayama, Andrew D.; Schindling, Casey; Dials, Katherine

    2018-01-01

    Although testing accommodations for standardized assessments are available for students with disabilities, interpretation remains challenging. The authors explored resilience to see if it could contribute to the interpretation of academic success for students who are deaf or hard of hearing or blind or have low vision. High school students (30…

  4. [Criteria for the assessment of the noise-induced occupational hearing loss: international and national standards].

    Science.gov (United States)

    Izmerov, N F; Denisov, É I; Adeninskaia, E E; Gorblianskiĭ, Iu Iu

    2014-01-01

    The objective of the present paper was to review international and national standards for the criteria of assessment of the noise-induced occupational loss of hearing. The importance of healthy hearing for the occupational safety is emphasized which implies the necessity of the more rigorous criteria for hearing conservation in the workers engaged in the noisy technological environment compared with those for the general population. A rationale for the development of the standard program of hearing conservation in the workers engaged in the noisy technological environment is proposed including hygienic norms and rules or national state standards.

  5. Improving Pharmacy Student Communication Outcomes Using Standardized Patients.

    Science.gov (United States)

    Gillette, Chris; Rudolph, Michael; Rockich-Winston, Nicole; Stanton, Robert; Anderson, H Glenn

    2017-08-01

    Objective. To examine whether standardized patient encounters led to an improvement in a student pharmacist-patient communication assessment compared to traditional active-learning activities within a classroom setting. Methods. A quasi-experimental study was conducted with second-year pharmacy students in a drug information and communication skills course. Student patient communication skills were assessed using high-stakes communication assessment. Results. Two hundred and twenty students' data were included. Students were significantly more likely to have higher scores on the communication assessment when they had higher undergraduate GPAs, were female, and taught using standardized patients. Similarly, students were significantly more likely to pass the assessment on the first attempt when they were female and when they were taught using standardized patients. Conclusion. Incorporating standardized patients within a communication course resulted in improved scores as well as first-time pass rates on a communication assessment than when using different methods of active learning.

  6. Assessing the quality of decision support technologies using the International Patient Decision Aid Standards instrument (IPDASi.

    Directory of Open Access Journals (Sweden)

    Glyn Elwyn

    Full Text Available To describe the development, validation and inter-rater reliability of an instrument to measure the quality of patient decision support technologies (decision aids.Scale development study, involving construct, item and scale development, validation and reliability testing.There has been increasing use of decision support technologies--adjuncts to the discussions clinicians have with patients about difficult decisions. A global interest in developing these interventions exists among both for-profit and not-for-profit organisations. It is therefore essential to have internationally accepted standards to assess the quality of their development, process, content, potential bias and method of field testing and evaluation.Scale development study, involving construct, item and scale development, validation and reliability testing.Twenty-five researcher-members of the International Patient Decision Aid Standards Collaboration worked together to develop the instrument (IPDASi. In the fourth Stage (reliability study, eight raters assessed thirty randomly selected decision support technologies.IPDASi measures quality in 10 dimensions, using 47 items, and provides an overall quality score (scaled from 0 to 100 for each intervention. Overall IPDASi scores ranged from 33 to 82 across the decision support technologies sampled (n = 30, enabling discrimination. The inter-rater intraclass correlation for the overall quality score was 0.80. Correlations of dimension scores with the overall score were all positive (0.31 to 0.68. Cronbach's alpha values for the 8 raters ranged from 0.72 to 0.93. Cronbach's alphas based on the dimension means ranged from 0.50 to 0.81, indicating that the dimensions, although well correlated, measure different aspects of decision support technology quality. A short version (19 items was also developed that had very similar mean scores to IPDASi and high correlation between short score and overall score 0.87 (CI 0.79 to 0.92.This work

  7. Radiation Safety Analysis In The NFEC For Assessing Possible Implementation Of The ICRP-60 Standard

    International Nuclear Information System (INIS)

    Yowono, I.

    1998-01-01

    Radiation safety analysis of the 3 facilities in the nuclear fuel element center (NFEC) for assessing possible implementation of the ICRP-60 standard has been done. The analysis has covered the radiation dose received by workers, dose rate in the working area, surface contamination level, air contamination level and the level of radioactive gas release to the environment. The analysis has been based on BATAN regulation and ICRP-60 standard. The result of the analysis has showed that the highest radiation dose received has been found to be only around 15% of the set value in the ICRP-60 standard and only 6% of the set value in the BATAN regulation. Thus the ICRP-60 as radiation safety standard could be implemented without changing the laboratory design

  8. Assessment of liquefaction-induced hazards using Bayesian networks based on standard penetration test data

    Science.gov (United States)

    Tang, Xiao-Wei; Bai, Xu; Hu, Ji-Lei; Qiu, Jiang-Nan

    2018-05-01

    Liquefaction-induced hazards such as sand boils, ground cracks, settlement, and lateral spreading are responsible for considerable damage to engineering structures during major earthquakes. Presently, there is no effective empirical approach that can assess different liquefaction-induced hazards in one model. This is because of the uncertainties and complexity of the factors related to seismic liquefaction and liquefaction-induced hazards. In this study, Bayesian networks (BNs) are used to integrate multiple factors related to seismic liquefaction, sand boils, ground cracks, settlement, and lateral spreading into a model based on standard penetration test data. The constructed BN model can assess four different liquefaction-induced hazards together. In a case study, the BN method outperforms an artificial neural network and Ishihara and Yoshimine's simplified method in terms of accuracy, Brier score, recall, precision, and area under the curve (AUC) of the receiver operating characteristic (ROC). This demonstrates that the BN method is a good alternative tool for the risk assessment of liquefaction-induced hazards. Furthermore, the performance of the BN model in estimating liquefaction-induced hazards in Japan's 2011 Tōhoku earthquake confirms its correctness and reliability compared with the liquefaction potential index approach. The proposed BN model can also predict whether the soil becomes liquefied after an earthquake and can deduce the chain reaction process of liquefaction-induced hazards and perform backward reasoning. The assessment results from the proposed model provide informative guidelines for decision-makers to detect the damage state of a field following liquefaction.

  9. Design standards for experimental and field studies to evaluate diagnostic accuracy of tests for infectious diseases in aquatic animals.

    Science.gov (United States)

    Laurin, E; Thakur, K K; Gardner, I A; Hick, P; Moody, N J G; Crane, M S J; Ernst, I

    2018-05-01

    Design and reporting quality of diagnostic accuracy studies (DAS) are important metrics for assessing utility of tests used in animal and human health. Following standards for designing DAS will assist in appropriate test selection for specific testing purposes and minimize the risk of reporting biased sensitivity and specificity estimates. To examine the benefits of recommending standards, design information from published DAS literature was assessed for 10 finfish, seven mollusc, nine crustacean and two amphibian diseases listed in the 2017 OIE Manual of Diagnostic Tests for Aquatic Animals. Of the 56 DAS identified, 41 were based on field testing, eight on experimental challenge studies and seven on both. Also, we adapted human and terrestrial-animal standards and guidelines for DAS structure for use in aquatic animal diagnostic research. Through this process, we identified and addressed important metrics for consideration at the design phase: study purpose, targeted disease state, selection of appropriate samples and specimens, laboratory analytical methods, statistical methods and data interpretation. These recommended design standards for DAS are presented as a checklist including risk-of-failure points and actions to mitigate bias at each critical step. Adherence to standards when designing DAS will also facilitate future systematic review and meta-analyses of DAS research literature. © 2018 John Wiley & Sons Ltd.

  10. The Changing Landscape of Alternate Assessments Based on Modified Academic Achievement Standards: An Analysis of Early Adopters of AA-MASs

    Science.gov (United States)

    Lazarus, Sheryl S.; Thurlow, Martha L.

    2009-01-01

    Several states had an assessment that they considered to be an alternate assessment based on modified academic achievement standards (AA-MAS) in place, or in development, when the April 2007 federal regulations on modified achievement standards were finalized. This article uses publicly available information collected by the National Center on…

  11. A prospective study assessing agreement and reliability of a geriatric evaluation

    OpenAIRE

    Locatelli, Isabella; Monod, St?fanie; Cornuz, Jacques; B?la, Christophe J.; Senn, Nicolas

    2017-01-01

    Background The present study takes place within a geriatric program, aiming at improving the diagnosis and management of geriatric syndromes in primary care. Within this program it was of prime importance to be able to rely on a robust and reproducible geriatric consultation to use as a gold standard for evaluating a primary care brief assessment tool. The specific objective of the present study was thus assessing the agreement and reliability of a comprehensive geriatric consultation. Method...

  12. Reviving common standards in point-count surveys for broad inference across studies

    Science.gov (United States)

    Steven M. Matsuoka; C. Lisa Mahon; Colleen M. Handel; Péter Sólymos; Erin M. Bayne; Patricia C. Fontaine; C. John Ralph

    2014-01-01

    We revisit the common standards recommended by Ralph et al. (1993, 1995a) for conducting point-count surveys to assess the relative abundance of landbirds breeding in North America. The standards originated from discussions among ornithologists in 1991 and were developed so that point-count survey data could be broadly compared and jointly analyzed by national data...

  13. American National Standard: criteria and guidelines for assessing capability for surface faulting at nuclear power plant sites

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    This standard provides applicants and consultants with criteria and guidelines for investigations directed toward the assessment of the capability for surface faulting at nuclear power plant sites. Assessment of vibratory ground motion resulting from faulting is not treated in these guidelines

  14. Study of International Standards of Risk Management

    Directory of Open Access Journals (Sweden)

    Dykan Volodymyr L.

    2014-01-01

    Full Text Available The goal of the article lies in the study of existing international standards of risk management, an important factor of improvement of risk management in domestic corporations and enterprises and development of recommendations on application of international standards in Ukraine, in particular, within the framework of building corporate systems of risk management. The conducted study shows that approaches on organisation of the process of risk management, used in standards of risk management, are of general character and differ with the degree of detailing. Their undoubted value in development of risk management in Ukraine is identification of a general direction of building corporate systems of risk management in practice. The said approaches at the national and corporate levels of standardisation in Ukraine within the framework of building corporate systems of risk management would allow improvement of risk management in corporations and enterprises. The prospect of further studies of domestic specialists in the field of risk management is development of the domestic standard of risk management with consideration of modern domestic specific features of development of risk management in Ukraine and leading foreign experience.

  15. Standards, criteria, comparative study. Final report 1993-1994

    International Nuclear Information System (INIS)

    David, M.

    1995-01-01

    The goal of this report is to compare standards and criteria used for the design of seismic resistant Nuclear Power plants in former USSR and Eastern Europe to the actual practice in Western Europe and USA. A review of USSR and Czech-Slovak standards for design of WWER-1000 NPPs is included. Comparative study deals involves a general comparison of standards and the comparison of seismic loads according to Eastern standards with the to-day practices. According to these comparisons it can be theoretically concluded that despite some differences the structural seismic forces calculated according to Soviet-Russian standards are in good agreement with the ones resulting from Western Standards

  16. study of the use of two standard- and non-standard-measuring devices

    Directory of Open Access Journals (Sweden)

    Paweł Ostapkowicz

    2014-03-01

    Full Text Available This paper deals with leak detection in liquid transmission pipelines. Diagnostic method based on negative pressure wave detection is taken into account here. The paper focuses on variant of this method, related to the use of only two measurement points (devices, placed at the inlet and outlet of the pipeline. Standard transducers for measurement of pressure signals and non-standard elaborated technique for measurement of new diagnostic signals were used. New diagnostic signals, conventionally named the signals of weak interactions, result from the work of special devices (correctors joined to the pipeline. In order to compare both hardware solutions key performance attributes for the analyzed leak detection method were determined. The bases of such assessment were experimental tests. They were conducted with the use of a physical model of a pipeline. The pipeline was 380 meters long, 34 mm in internal diameter and made of polyethylene (PEHD pipes. The medium pumped through the pipeline was water. Carrying out such research, diagnostic procedures elaborated by the author were used and tested.[b]Keywords[/b]: technical diagnostics, pipelines, leak detection

  17. The Standard Assessment Tasks and the Boycott at Key Stage 1: Teachers' and Headteachers' Views in Six Inner-City Schools.

    Science.gov (United States)

    West, Anne; And Others

    1994-01-01

    Reports a study that examined headteachers' perspectives on England's 1993 teacher boycott of government-imposed standard assessment tasks (SATs) for elementary students together with teachers' attitudes toward the tasks, their management, and the boycott. Findings confirmed that, by 1993, resistance to national testing at that age was firmly…

  18. The Astronomy and Space Science Concept Inventory: Assessment Instruments Aligned with the K-12 National Science Standards

    Science.gov (United States)

    Sadler, Philip M.

    2011-01-01

    We report on the development of an item test bank and associated instruments based on those K-12 national standards which involve astronomy and space science. Utilizing hundreds of studies in the science education research literature on student misconceptions, we have constructed 211 unique items that measure the degree to which students abandon such ideas for accepted scientific views. Piloted nationally with 7599 students and their 88 teachers spanning grades 5-12, the items reveal a range of interesting results, particularly student difficulties in mastering the NRC Standards and AAAS Benchmarks. Teachers generally perform well on items covering the standards of the grade level at which they teach, exhibiting few misconceptions of their own. Teachers dramatically overestimate their students’ performance, perhaps because they are unaware of their students’ misconceptions. Examples are given showing how the developed instruments can be used to assess the effectiveness of instruction and to evaluate the impact of professional development activities for teachers.

  19. Standards in neurosonology. Part I

    Directory of Open Access Journals (Sweden)

    Joanna Wojcza

    2015-09-01

    Full Text Available The paper presents standards related to ultrasound imaging of the cerebral vasculature and structures. The aim of this paper is to standardize both the performance and description of ultrasound imaging of the extracranial and intracranial cerebral arteries as well as a study of a specifi c brain structure, i.e. substantia nigra hyperechogenicity. The following aspects are included in the description of standards for each ultrasonographic method: equipment requirements, patient preparation, study technique and documentation as well as the required elements of ultrasound description. Practical criteria for the diagnosis of certain pathologies in accordance with the latest literature were also presented. Furthermore, additional comments were included in some of the sections. Part I discusses standards for the performance, documentation and description of different ultrasound methods (Duplex, Doppler. Part II and III are devoted to standards for specifi c clinical situations (vasospasm, monitoring after the acute stage of stroke, detection of a right-toleft shunts, confi rmation of the arrest of the cerebral circulation, an assessment of the functional effi ciency of circle of Willis, an assessment of the cerebrovascular vasomotor reserve as well as the measurement of substantia nigra hyperechogenicity.

  20. Standards in neurosonology. Part III

    Directory of Open Access Journals (Sweden)

    Joanna Wojczal

    2016-06-01

    Full Text Available The paper presents standards related to ultrasound imaging of the cerebral vasculature and structures. The aim of this paper is to standardize both the performance and description of ultrasound imaging of the extracranial and intracranial cerebral arteries as well as a study of a specific brain structure, i.e. substantia nigra hyperechogenicity. The following aspects are included in the description of standards for each ultrasonographic method: equipment requirements, patient preparation, study technique and documentation as well as the required elements of ultrasound description. Practical criteria for the diagnosis of certain pathologies in accordance with the latest literature were also presented. Furthermore, additional comments were included in some of the sections. Part I discusses standards for the performance, documentation and description of different ultrasound methods (Duplex, Doppler. Part II and III are devoted to standards for specific clinical situations (vasospasm, monitoring after the acute stage of stroke, detection of a right-to-left shunts, confirmation of the arrest of the cerebral circulation, an assessment of the functional efficiency of circle of Willis, an assessment of the cerebrovascular vasomotor reserve as well as the measurement of substantia nigra hyperechogenicity.

  1. Standardizing assessment practices of undergraduate medical competencies across medical schools: challenges, opportunities and lessons learned from a consortium of medical schools in Uganda.

    Science.gov (United States)

    Mubuuke, Aloysius Gonzaga; Mwesigwa, Catherine; Maling, Samuel; Rukundo, Godfrey; Kagawa, Mike; Kitara, David Lagoro; Kiguli, Sarah

    2014-01-01

    Health professions education is gradually moving away from the more traditional approaches to new innovative ways of training aimed at producing professionals with the necessary competencies to address the community health needs. In response to these emerging trends, Medical Education for Equitable Services to All Ugandans (MESAU), a consortium of Ugandan medical schools developed key competencies desirable of graduates and successfully implemented Competency Based Education (CBE) for undergraduate medical students. To examine the current situation and establish whether assessment methods of the competencies are standardized across MESAU schools as well as establish the challenges, opportunities and lessons learned from the MESAU consortium. It was a cross-sectional descriptive study involving faculty of the medical schools in Uganda. Data was collected using focus group discussions and document reviews. Findings were presented in form of themes. Although the MESAU schools have implemented the developed competencies within their curricular, the assessment methods are still not standardized with each institution having its own assessment procedures. Lack of knowledge and skills regarding assessment of the competencies was evident amongst the faculty. The fear for change amongst lecturers was also noted as a major challenge. However, the institutional collaboration created while developing competencies was identified as key strength. Findings demonstrated that despite having common competencies, there is no standardized assessment blue print applicable to all MESAU schools. Continued collaboration and faculty development in assessment is strongly recommended.

  2. Assessment of the Adequacy of Instructional Resources in Business Education Programmes Relative to NCCE Standards for Colleges of Education in Nigeria

    Science.gov (United States)

    Onyesom, Moses; Okolocha, Chimezie Comfort

    2013-01-01

    The study assessed the adequacy of instructional resources available for business education programmes at the colleges of education in Edo and Delta states of Nigeria in relation to the standards stipulated by the National Commission for Colleges of Education (NCCE). The study adopted the ex-post facto research design and was guided by five…

  3. Using a CAS Self-Study to Teach Assessment Practice

    Science.gov (United States)

    Bourke, Brian

    2017-01-01

    There are likely as many approaches to teaching assessment as there are people teaching assessment. Graduate courses on assessment can be structured with a singular focus, such as learning outcomes assessment, or along a competencies-based framework. Such frameworks include the Assessment Skills and Knowledge (ASK) Standards developed by College…

  4. Standard Guide for Acousto-Ultrasonic Assessment of Composites, Laminates, and Bonded Joints

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This guide explains the rationale and basic technology for the acousto-ultrasonic (AU) method. Guidelines are given for nondestructive evaluation (NDE) of flaws and physical characteristics that influence the mechanical properties and relative strength of composite structures (for example, filament-wound pressure vessels), adhesive bonds (for example, joints between metal plates), and interlaminar and fiber/matrix bonds in man-made composites and natural composites (for example, wood products). 1.2 This guide covers technical details and rules that must be observed to ensure reliable and reproducible quantitative AU assessments of laminates, composites, and bonded structures. The underlying principles, prototype apparatus, instrumentation, standardization, examination methods, and data analysis for such assessments are covered. Limitations of the AU method and guidelines for taking advantage of its capabilities are cited. 1.3 The objective of AU is to assess subtle flaws and associated strength variations...

  5. Criterion and convergent validity of the Montreal cognitive assessment with screening and standardized neuropsychological testing.

    Science.gov (United States)

    Lam, Benjamin; Middleton, Laura E; Masellis, Mario; Stuss, Donald T; Harry, Robin D; Kiss, Alex; Black, Sandra E

    2013-12-01

    To compare the validity of the Montreal Cognitive Assessment (MoCA) with the criterion standard of standardized neuropsychological testing and to compare the convergent validity of the MoCA with that of existing screening tools and global measures of cognition. Cross-sectional observational study. Tertiary care hospital-based cognitive neurology subspecialty clinic. A convenience sample of 107 individuals with mild Alzheimer's disease (AD, n=75) or mild cognitive impairment (MCI, n=32) from the Sunnybrook Dementia Study. In addition to the MoCA, all participants completed the Mini-Mental State Examination (MMSE), the Mattis Dementia Rating Scale (DRS), and detailed neuropsychological testing. Convergent validity was supported, with MoCA scores correlating well with the MMSE (correlation coefficient (r)=0.66, Pvalidity was supported, with MoCA subscores according to cognitive domain correlating well with analogous neuropsychological tests and, in the case of memory (area under the receiver operating characteristic curve (AUC)=0.86), executive (AUC=0.79), and visuospatial function (AUC=0.79), being reasonably sensitive to impairment in those domains. The MoCA is a valid assessment of cognition that shows good agreement with existing screening tools and global measures (convergent validity) and was superior to the MMSE in this regard. The MoCA domain-specific subscores align with performance on more-detailed neuropsychological tests, suggesting not only good criterion validity for the MoCA, but also that it may be useful in guiding further neuropsychological testing. © 2013, Copyright the Authors Journal compilation © 2013, The American Geriatrics Society.

  6. Development of reliability-based design and assessment standards for onshore gas transmission pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Joe; Rothwell, Brian [TransCanada PipeLines Ltd., Calgary, AB (Canada); Nessim, Maher; Zhou, Wenxing [C-FER Technologies, Edmonton, AB (Canada)

    2005-07-01

    Onshore pipelines have traditionally been designed with a deterministic stress based methodology. The changing operating environment has however imposed many challenges to the pipeline industry, including heightened public awareness of risk, more challenging natural hazards and increased economic competitiveness. To meet the societal expectation of pipeline safety and enhance the competitiveness of the pipeline industry, significant efforts have been spent for the development of reliability-based design and assessment (RBDA) methodology. This paper will briefly review the technology development in the RBDA area and the focus will be on the progresses in the past years in standard development within the American Society of Mechanical Engineers (ASME) and the Canadian Standard Association (CSA) organizations. (author)

  7. Customized vs INTERGROWTH-21st standards for the assessment of birthweight and stillbirth risk at term.

    Science.gov (United States)

    Francis, Andre; Hugh, Oliver; Gardosi, Jason

    2018-02-01

    Fetal growth abnormalities are linked to stillbirth and other adverse pregnancy outcomes, and use of the correct birthweight standard is essential for accurate assessment of growth status and perinatal risk. Two competing, conceptually opposite birthweight standards are currently being implemented internationally: customized gestation-related optimal weight (GROW) and INTERGROWTH-21 st . We wanted to compare their performance when applied to a multiethnic international cohort, and evaluate their usefulness in the assessment of stillbirth risk at term. We analyzed routinely collected maternity data from 10 countries with a total of 1.25 million term pregnancies in their respective main ethnic groups. The 2 standards were applied to determine small for gestational age (SGA) and large for gestational age (LGA) rates, with associated relative risk and population-attributable risk of stillbirth. The customized standard (GROW) was based on the term optimal weight adjusted for maternal height, weight, parity, and ethnic origin, while INTERGROWTH-21 st was a fixed standard derived from a multiethnic cohort of low-risk pregnancies. The customized standard showed an average SGA rate of 10.5% (range 10.1-12.7) and LGA rate of 9.5% (range 7.3-9.9) for the set of cohorts. In contrast, there was a wide variation in SGA and LGA rates with INTERGROWTH-21 st , with an average SGA rate of 4.4% (range 3.1-16.8) and LGA rate of 20.6% (range 5.1-27.5). This variation in INTERGROWTH-21 st SGA and LGA rates was correlated closely (R = ±0.98) to the birthweights predicted for the 10 country cohorts by the customized method to derive term optimal weight, suggesting that they were mostly due to physiological variation in birthweight. Of the 10.5% of cases defined as SGA according to the customized standard, 4.3% were also SGA by INTERGROWTH-21 st and had a relative risk of 3.5 (95% confidence interval, 3.1-4.1) for stillbirth. A further 6.3% (60% of the whole customized SGA) were not SGA

  8. A Serious Game for Clinical Assessment of Cognitive Status: Validation Study.

    Science.gov (United States)

    Tong, Tiffany; Chignell, Mark; Tierney, Mary C; Lee, Jacques

    2016-05-27

    We propose the use of serious games to screen for abnormal cognitive status in situations where it may be too costly or impractical to use standard cognitive assessments (eg, emergency departments). If validated, serious games in health care could enable broader availability of efficient and engaging cognitive screening. The objective of this work is to demonstrate the feasibility of a game-based cognitive assessment delivered on tablet technology to a clinical sample and to conduct preliminary validation against standard mental status tools commonly used in elderly populations. We carried out a feasibility study in a hospital emergency department to evaluate the use of a serious game by elderly adults (N=146; age: mean 80.59, SD 6.00, range 70-94 years). We correlated game performance against a number of standard assessments, including the Mini-Mental State Examination (MMSE), Montreal Cognitive Assessment (MoCA), and the Confusion Assessment Method (CAM). After a series of modifications, the game could be used by a wide range of elderly patients in the emergency department demonstrating its feasibility for use with these users. Of 146 patients, 141 (96.6%) consented to participate and played our serious game. Refusals to play the game were typically due to concerns of family members rather than unwillingness of the patient to play the game. Performance on the serious game correlated significantly with the MoCA (r=-.339, P games in a clinical setting. Further research is required to demonstrate the validity and reliability of game-based assessments for clinical decision making.

  9. A Serious Game for Clinical Assessment of Cognitive Status: Validation Study

    Science.gov (United States)

    Chignell, Mark; Tierney, Mary C.; Lee, Jacques

    2016-01-01

    Background We propose the use of serious games to screen for abnormal cognitive status in situations where it may be too costly or impractical to use standard cognitive assessments (eg, emergency departments). If validated, serious games in health care could enable broader availability of efficient and engaging cognitive screening. Objective The objective of this work is to demonstrate the feasibility of a game-based cognitive assessment delivered on tablet technology to a clinical sample and to conduct preliminary validation against standard mental status tools commonly used in elderly populations. Methods We carried out a feasibility study in a hospital emergency department to evaluate the use of a serious game by elderly adults (N=146; age: mean 80.59, SD 6.00, range 70-94 years). We correlated game performance against a number of standard assessments, including the Mini-Mental State Examination (MMSE), Montreal Cognitive Assessment (MoCA), and the Confusion Assessment Method (CAM). Results After a series of modifications, the game could be used by a wide range of elderly patients in the emergency department demonstrating its feasibility for use with these users. Of 146 patients, 141 (96.6%) consented to participate and played our serious game. Refusals to play the game were typically due to concerns of family members rather than unwillingness of the patient to play the game. Performance on the serious game correlated significantly with the MoCA (r=–.339, P games in a clinical setting. Further research is required to demonstrate the validity and reliability of game-based assessments for clinical decision making. PMID:27234145

  10. Adaptation and standardization of a Western tool for assessing child development in non-Western low-income context

    Directory of Open Access Journals (Sweden)

    Teklu Gemechu Abessa

    2016-07-01

    Full Text Available Abstract Background Due to lack of culturally relevant assessment tools, little is known about children’s developmental profiles in low income settings such as Ethiopia. The objective of this study was to adapt and standardize the Denver II for assessing child development in Jimma Zone, South West Ethiopia. Methods Culture-specific test items in Denver II were modified. After translation into two local languages, all test items were piloted and fine-tuned. Using 1597 healthy children 4 days to 70.6 months of age, the 25, 50, 75 and 90 % passing ages were determined for each test item as milestones. Milestones attainment on the adapted version and the Denver II were compared on the 90 % passing age. Reliability of the adapted tool was examined. Results A total of 36 (28.8 % test items, mostly from personal social domain, were adapted. Milestones attainment ages on the two versions differed significantly on 42 (34 % test items. The adapted tool has an excellent inter-rater on 123 (98 % items and substantial to excellent test-retest reliability on 119 (91 % items. Conclusions A Western developmental assessment tool can be adapted reliably for use in low-income settings. Age differences in attaining milestones indicate a correct estimation of child development requires a population-specific standard.

  11. Reliability and validity of the Farsi version of the standardized assessment of personality-abbreviated scale

    Directory of Open Access Journals (Sweden)

    Maryam Sepehri

    2017-06-01

    Full Text Available Introduction: A short screening tool for high-risk individuals with personality disorder (PD is useful both for clinicians and researchers. The aim of this study was to assess the validity and reliability of the Farsi version of the Standardized Assessment of Personality-Abbreviated Scale (SAPAS. Methods: The original English version of the SAPAS questionnaire was translated into Farsi, and then, translated back into English by two professionals. A survey was then conducted using the questionnaire on 150 clients of primary health care centers in Tabriz, Iran. A total of 235 medical students were also studied for the reliability assessment of the questionnaire. The SAPAS was compared to the short form of Minnesota Multiphasic Personality Inventory (MMPI. The data analysis was performed using receiver operating characteristic (ROC curve technique, operating characteristic for diagnostic efficacy, Cronbach's alpha, and test-retest for reliability evaluation. Results: We found an area under the curve (AUC of 0.566 [95% confidence intervals (CI: 0.455-0.677]; sensitivity of 0.89 and specificity of 0.26 at the cut-off score of 2 and higher. The total Cronbach's alpha coefficient was 0.38 and Cohen's kappa ranged between 0.5 and 0.8. Conclusion: The current study showed that the Farsi version of the SAPAS was relatively less efficient, in term of validity and reliability, in the screening of PD in the population.

  12. Punica granatum L. Hydrogel for Wound Care Treatment: From Case Study to Phytomedicine Standardization.

    Science.gov (United States)

    Fleck, Aline; Cabral, Patrik F G; Vieira, Felipe F M; Pinheiro, Deo A; Pereira, Carlos R; Santos, Wilson C; Machado, Thelma B

    2016-08-22

    The pharmacological activities of many Punica granatum L. components suggest a wide range of clinical applications for the prevention and treatment of diseases where chronic inflammation is believed to play an essential etiologic role. The current work reports a case study analyzing the effect produced by a magistral formulation of ethanolic extracts of Punica granatum peels on a non-healing chronic ulcer. The complete closure of the chronic ulcer that was initially not responsive to standard medical care was observed. A 2% (w/w) P. granatum peels ethanolic extract hydrogel-based formulation (PGHF) was standardized and subjected to physicochemical studies to establish the quality control parameters using, among others, assessment criteria such as optimum appearance, pH range, viscosity and hydrogel disintegration. The stability and quantitative chromatographic data was assessed in storage for six months under two temperature regimes. An efficient HPLC-DAD method was established distinguishing the biomarkers punicalin and punicalagin simultaneously in a single 8 min run. PGHF presented suitable sensorial and physicochemical performance, showing that punicalagin was not significantly affected by storage (p > 0.05). Formulations containing extracts with not less than 0.49% (w/w) total punicalagin might find good use in wound healing therapy.

  13. Short-term effects of a standardized glucose load on region-specific aortic pulse wave velocity assessed by MRI

    NARCIS (Netherlands)

    Jonker, J.T.; Tjeerdema, N.; Hensen, L.C.; Lamb, H.J.; Romijn, J.A.; Smit, J.W.; Westenberg, J.J.; Roos, A. de

    2014-01-01

    PURPOSE: To assess the short-term effects of a standardized oral glucose load on regional aortic pulse wave velocity (PWV) using two-directional in-plane velocity encoded MRI. MATERIALS AND METHODS: A randomized, controlled intervention was performed in 16 male subjects (mean +/- standard deviation:

  14. Investigation of Science Inquiry Items for Use on an Alternate Assessment Based on Modified Achievement Standards Using Cognitive Lab Methodology

    Science.gov (United States)

    Dickenson, Tammiee S.; Gilmore, Joanna A.; Price, Karen J.; Bennett, Heather L.

    2013-01-01

    This study evaluated the benefits of item enhancements applied to science-inquiry items for incorporation into an alternate assessment based on modified achievement standards for high school students. Six items were included in the cognitive lab sessions involving both students with and without disabilities. The enhancements (e.g., use of visuals,…

  15. Is It Working? Distractor Analysis Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-05-01

    The Test Of Astronomy STandards (TOAST) assessment instrument is a multiple-choice survey tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) have been conducting a question-by-question distractor analysis procedure to determine the sensitivity and effectiveness of each item. In brief, the frequency each possible answer choice, known as a foil or distractor on a multiple-choice test, is determined and compared to the existing literature on the teaching and learning of astronomy. In addition to having statistical difficulty and discrimination values, a well functioning assessment item will show students selecting distractors in the relative proportions to how we expect them to respond based on known misconceptions and reasoning difficulties. In all cases, our distractor analysis suggests that all items are functioning as expected. These results add weight to the validity of the Test Of Astronomy STandards (TOAST) assessment instrument, which is designed to help instructors and researchers measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  16. A prospective study assessing agreement and reliability of a geriatric evaluation.

    Science.gov (United States)

    Locatelli, Isabella; Monod, Stéfanie; Cornuz, Jacques; Büla, Christophe J; Senn, Nicolas

    2017-07-19

    The present study takes place within a geriatric program, aiming at improving the diagnosis and management of geriatric syndromes in primary care. Within this program it was of prime importance to be able to rely on a robust and reproducible geriatric consultation to use as a gold standard for evaluating a primary care brief assessment tool. The specific objective of the present study was thus assessing the agreement and reliability of a comprehensive geriatric consultation. The study was conducted at the outpatient clinic of the Service of Geriatric Medicine, University of Lausanne, Switzerland. All community-dwelling older persons aged 70 years and above were eligible. Patients were excluded if they hadn't a primary care physician, they were unable to speak French, or they were already assessed by a geriatrician within the last 12 months. A set of 9 geriatricians evaluated 20 patients. Each patient was assessed twice within a 2-month delay. Geriatric consultations were based on a structured evaluation process, leading to rating the following geriatric conditions: functional, cognitive, visual, and hearing impairment, mood disorders, risk of fall, osteoporosis, malnutrition, and urinary incontinence. Reliability and agreement estimates on each of these items were obtained using a three-way Intraclass Correlation and a three-way Observed Disagreement index. The latter allowed a decomposition of overall disagreement into disagreements due to each source of error variability (visit, rater and random). Agreement ranged between 0.62 and 0.85. For most domains, geriatrician-related error variability explained an important proportion of disagreement. Reliability ranged between 0 and 0.8. It was poor/moderate for visual impairment, malnutrition and risk of fall, and good/excellent for functional/cognitive/hearing impairment, osteoporosis, incontinence and mood disorders. Six out of nine items of the geriatric consultation described in this study (functional

  17. The Impact of Excluding Food Guarding from a Standardized Behavioral Canine Assessment in Animal Shelters

    Science.gov (United States)

    Mohan-Gibbons, Heather; Dolan, Emily D.; Reid, Pamela; Slater, Margaret R.; Mulligan, Hugh; Weiss, Emily

    2018-01-01

    Simple Summary Recent research has called into question the value of the food guarding assessment as a predictive tool for determining the safety of shelter dogs. This study examined the effect of eliminating the food guarding assessment in nine U.S. animal shelters. It was found that when the food guarding assessment was removed, bites or other injuries to staff or adopters did not increase. However, dogs exhibiting food guarding behavior were less likely to be adopted, had a longer shelter stay, and were more likely to be euthanized than dogs in the general population. Based on previous research and this study’s findings, the authors recommend that shelters discontinue the food guarding assessment. Abstract Many shelters euthanize or restrict adoptions for dogs that exhibit food guarding while in the animal shelter. However, previous research showed that only half the dogs exhibiting food guarding during an assessment food guard in the home. So, dogs are often misidentified as future food guarders during shelter assessments. We examined the impact of shelters omitting food guarding assessments. Nine shelters conducted a two-month baseline period of assessing for food guarding followed by a two-month investigative period during which they omitted the food guarding assessment. Dogs that guarded their food during a standardized assessment were less likely to be adopted, had a longer shelter stay, and were more likely to be euthanized. When the shelters stopped assessing for food guarding, there was no significant difference in the rate of returns of food guarding dogs, even though more dogs were adopted because fewer were identified with food guarding behavior. Additionally, the number of injuries to staff, volunteers, and adopters was low (104 incidents from a total of 14,180 dogs) and did not change when the food guarding assessment was omitted. These results support a recommendation that shelters discontinue the food guarding assessment. PMID:29419746

  18. Theoretical Study of Watershed Eco-Compensation Standards

    Science.gov (United States)

    Yan, Dandan; Fu, Yicheng; Liu, Biu; Sha, Jinxia

    2018-01-01

    Watershed eco-compensation is an effective way to solve conflicts over water allocation and ecological destruction problems in the exploitation of water resources. Despite an increasing interest in the topic, the researches has neglected the effect of water quality and lacked systematic calculation method. In this study we reviewed and analyzed the current literature and proposedatheoretical framework to improve the calculation of co-compensation standard.Considering the perspectives of the river ecosystems, forest ecosystems and wetland ecosystems, the benefit compensation standard was determined by the input-output corresponding relationship. Based on the opportunity costs related to limiting development and water conservation loss, the eco-compensation standard was calculated.In order to eliminate the defects of eco-compensation implementation, the improvement suggestions were proposed for the compensation standard calculation and implementation.

  19. Standard for assessment of fuel integrity under anticipated operational occurrences in BWR power plant:2002

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Suzuki, Riichiro; Komura, Seiichi; Kudo, Yoshiro; Yamanaka, Akihiro; Oomizu, Satoru; Kitamura, Hideya; Nagata, Yoshifumi

    2003-01-01

    To secure fuel integrity, a Light Water Reactor (LWR) core is designed so that no boiling transition (BT) should take place in fuel assemblies and excessive rise in fuel cladding temperature due to deteriorated that transfer should be avoided in Anticipated Operational Occurrences (AOO). In some AOO in a Boiling Water Reactor (BWR), however, the rise in reactor power could be limited by SCRAM or void reactivity effect. Recent studies have provided accumulated knowledge that even if BT takes place in fuel assemblies, the rise in fuel cladding temperature could be so small that it will not threat to fuel integrity, as long as the BT condition terminates within a short period of time. In addition, appropriate methods have been developed to evaluate the cladding temperature during dryout. This standard provides requirements in the assessment of fuel integrity under AOO in which limited-BT condition is temporarily reached and the propriety of reusing a fuel assembly that has experienced limited-BT condition. The standard has been approved by the Atomic Energy Society of Japan following deliberation by impartial members for two and half years. It is now expected that this standard will provide an effective measure for the rational expansion of fuel design and operational margin. (author)

  20. The development and standardization of Self-assessment for Hearing Screening of the Elderly.

    Science.gov (United States)

    Kim, Gibbeum; Na, Wondo; Kim, Gungu; Han, Woojae; Kim, Jinsook

    2016-01-01

    The present study aimed to develop and standardize a screening tool for elderly people who wish to check for themselves their level of hearing loss. The Self-assessment for Hearing Screening of the Elderly (SHSE) consisted of 20 questions based on the characteristics of presbycusis using a five-point scale: seven questions covered general issues related to sensorineural hearing loss, seven covered hearing difficulty under distracting listening conditions, two covered hearing difficulty with fast-rated speech, and four covered the working memory function during communication. To standardize SHSE, 83 elderly participants took part in the study: 25 with normal hearing, and 22, 23, and 13 with mild, moderate, and moderate-to-severe sensorineural hearing loss, respectively, according to their hearing sensitivity. All were retested 3 weeks later using the same questionnaire to confirm its reliability. In addition, validity was assessed using various hearing tests such as a sentence test with background noise, a time-compressed speech test, and a digit span test. SHSE and its subcategories showed good internal consistency. SHSE and its subcategories demonstrated high test-retest reliability. A high correlation was observed between the total scores and pure-tone thresholds, which indicated gradually increased SHSE scores of 42.24%, 55.27%, 66.61%, and 78.15% for normal hearing, mild, moderate, and moderate-to-severe groups, respectively. With regard to construct validity, SHSE showed a high negative correlation with speech perception scores in noise and a moderate negative correlation with scores of time-compressed speech perception. However, there was no statistical correlation between digit span results and either the SHSE total or its subcategories. A confirmatory factor analysis supported three factors in SHSE. We found that the developed SHSE had valuable internal consistency, test-retest reliability, and convergent and construct validity. These results suggest that

  1. Best Practices in Physics Program Assessment: Should APS Provide Accreditation Standards for Physics?

    Science.gov (United States)

    Hodapp, Theodore

    The Phys21 report, ``Preparing Physics Students for 21st Century Careers,'' provides guidance for physics programs to improve their degree programs to make them more relevant for student career choices. Undertaking such changes and assessing impact varies widely by institution, with many departments inventing assessments with each periodic departmental or programmatic review. American Physical Society has embarked on a process to integrate information from Phys21, the results of other national studies, and educational research outcomes to generate a best-practices guide to help physics departments conduct program review, assessment, and improvement. It is anticipated that departments will be able to use this document to help with their role in university-level accreditation, and in making the case for improvements to departmental programs. Accreditation of physics programs could stem from such a document, and I will discuss some of the thinking of the APS Committee on Education in creating this guide, and how they are advising APS to move forward in the higher education landscape that is increasingly subject to standards-based evaluations. I will describe plans for the design, review, and dissemination of this guide, and how faculty can provide input into its development. This material is based upon work supported by the National Science Foundation under Grant No. 1540570. Opinions expressed do not necessarily reflect those of the NSF.

  2. Yttrium-90 Radioembolization for Unresectable Standard-chemorefractory Intrahepatic Cholangiocarcinoma: Survival, Efficacy, and Safety Study

    Energy Technology Data Exchange (ETDEWEB)

    Rafi, Shoaib; Piduru, Sarat M. [Emory University School of Medicine, Division of Interventional Radiology and Image Guided Medicine, Department of Radiology (United States); El-Rayes, Bassel; Kauh, John S. [Emory University School of Medicine, Department of Hematology and Medical Oncology (United States); Kooby, David A.; Sarmiento, Juan M. [Emory University School of Medicine, Department of Surgical Oncology in Surgery (United States); Kim, Hyun S., E-mail: kevin.kim@emory.edu [Emory University School of Medicine, Division of Interventional Radiology and Image Guided Medicine, Department of Radiology (United States)

    2013-04-15

    To assess the overall survival, efficacy, and safety of radioembolization with yttrium-90 (Y90) for unresectable standard-chemorefractory intrahepatic cholangiocarcinoma (ICC). Patients with unresectable standard-chemorefractory ICC treated with Y90 were studied. Survival was calculated from the date of first Y90 procedure. Tumor response was assessed with the Response Evaluation Criteria in Solid Tumors criteria on follow-up computed tomography or magnetic resonance imaging scans. National Cancer Institute Common Terminology Criteria (NCI CTCAE), version 3, were used for complications. Statistical analysis was performed by the Kaplan-Meier estimator by the log rank test. Nineteen patients underwent a total of 24 resin-based Y90 treatments. Median survival from the time of diagnosis and first Y90 procedure was 752 {+-} 193 [95 % confidence interval (CI) 374-1130] and 345 {+-} 128 (95 % CI 95-595) days, respectively. Median survival with Eastern Cooperative Oncology Group (ECOG) performance status 1 (n = 15) and ECOG performance status 2 (n = 4) was 450 {+-} 190 (95 % CI 78-822) and 345 {+-} 227 (95 % CI 0-790) days, respectively (p = .214). Patients with extrahepatic metastasis (n = 11) had a median survival of 404 {+-} 309 (95 % CI 0-1010) days versus 345 {+-} 117 (95 % CI 115-575) days for patients without metastasis (n = 8) (p = .491). No mortality was reported within 30 days from first Y90 radioembolization. One patient developed grade 3 thrombocytopenia as assessed by NCI CTCAE. Fatigue and transient abdominal pain were observed in 4 (21 %) and 6 (32 %) patients, respectively. Y90 radioembolization is effective for unresectable standard-chemorefractory ICC.

  3. Standardizing metadata and taxonomic identification in metabarcoding studies.

    Science.gov (United States)

    Tedersoo, Leho; Ramirez, Kelly S; Nilsson, R Henrik; Kaljuvee, Aivi; Kõljalg, Urmas; Abarenkov, Kessy

    2015-01-01

    High-throughput sequencing-based metabarcoding studies produce vast amounts of ecological data, but a lack of consensus on standardization of metadata and how to refer to the species recovered severely hampers reanalysis and comparisons among studies. Here we propose an automated workflow covering data submission, compression, storage and public access to allow easy data retrieval and inter-study communication. Such standardized and readily accessible datasets facilitate data management, taxonomic comparisons and compilation of global metastudies.

  4. Patients’ handling of a standardized medication plan: a pilot study and method development

    Directory of Open Access Journals (Sweden)

    Botermann L

    2016-04-01

    Full Text Available Lea Botermann,1,2 Katrin Krueger,1 Christiane Eickhoff,1 Charlotte Kloft,2 Martin Schulz1–31Department of Medicine, ABDA – Federal Union of German Associations of Pharmacists, Berlin, 2Department of Clinical Pharmacy and Biochemistry, Institute of Pharmacy, Freie Universitaet Berlin, Berlin, 3Department of Pharmacology, Goethe-University Frankfurt, Frankfurt am Main, GermanyPurpose: The Action Plan for Medication Safety by the German Federal Ministry of Health introduced a standardized medication plan (MP, a printable document for the patient. The practical handling needs to be tested before the nationwide implementation in Germany. Therefore, the aims of our study were 1 to develop an instrument to evaluate the usage of the standardized MP, 2 to assess if patients can locate, and 3 understand important information. Moreover, we explored patients’ opinion and suggestions regarding the standardized MP template.Patients and methods: We conducted a cross-sectional study to evaluate the practical handling of the standardized MP. We interviewed 40 adult patients in seven community pharmacies in Germany, who took at least five medicines regularly and gave their written informed consent. The interview consisted of questions regarding finding and understanding information provided on a mock-up MP, patients’ opinion and the execution of the information on the MP by filling pill boxes. We eventually developed a new evaluation method to quantify the practical handling of the MP by rating the pill boxes filled by the patients.Results: Overall, the participants rated the MP positively. Thirty-nine (98% participants found important information on a mock-up standardized MP. Patients were questioned to identify if they understood information on medical intake as it relates to meals. In particular, they were questioned about medicine intake “1 hour before a meal”, which 98% (n=39 interpreted correctly, and “during a meal”, which 100% (n=40

  5. Content and Alignment of State Writing Standards and Assessments as Predictors of Student Writing Achievement: An Analysis of 2007 National Assessment of Educational Progress Data

    Science.gov (United States)

    Troia, Gary A.; Olinghouse, Natalie G.; Zhang, Mingcai; Wilson, Joshua; Stewart, Kelly A.; Mo, Ya; Hawkins, Lisa

    2018-01-01

    We examined the degree to which content of states' writing standards and assessments (using measures of content range, frequency, balance, and cognitive complexity) and their alignment were related to student writing achievement on the 2007 National Assessment of Educational Progress (NAEP), while controlling for student, school, and state…

  6. Standardizing assessment practices of undergraduate medical competencies across medical schools: challenges, opportunities and lessons learned from a consortium of medical schools in Uganda

    Science.gov (United States)

    Mubuuke, Aloysius Gonzaga; Mwesigwa, Catherine; Maling, Samuel; Rukundo, Godfrey; Kagawa, Mike; Kitara, David Lagoro; Kiguli, Sarah

    2014-01-01

    Introduction Health professions education is gradually moving away from the more traditional approaches to new innovative ways of training aimed at producing professionals with the necessary competencies to address the community health needs. In response to these emerging trends, Medical Education for Equitable Services to All Ugandans (MESAU), a consortium of Ugandan medical schools developed key competencies desirable of graduates and successfully implemented Competency Based Education (CBE) for undergraduate medical students. Objectives To examine the current situation and establish whether assessment methods of the competencies are standardized across MESAU schools as well as establish the challenges, opportunities and lessons learned from the MESAU consortium. Methods It was a cross-sectional descriptive study involving faculty of the medical schools in Uganda. Data was collected using focus group discussions and document reviews. Findings were presented in form of themes. Results Although the MESAU schools have implemented the developed competencies within their curricular, the assessment methods are still not standardized with each institution having its own assessment procedures. Lack of knowledge and skills regarding assessment of the competencies was evident amongst the faculty. The fear for change amongst lecturers was also noted as a major challenge. However, the institutional collaboration created while developing competencies was identified as key strength. Conclusion Findings demonstrated that despite having common competencies, there is no standardized assessment blue print applicable to all MESAU schools. Continued collaboration and faculty development in assessment is strongly recommended. PMID:25995778

  7. TRANSPORT LOCOMOTIVE AND WASTE PACKAGE TRANSPORTER ITS STANDARDS IDENTIFICATION STUDY

    International Nuclear Information System (INIS)

    Draper, K.D.

    2005-01-01

    To date, the project has established important to safety (ITS) performance requirements for structures, systems and components (SSCs) based on identification and categorization of event sequences that may result in a radiological release. These performance requirements are defined within the ''Nuclear Safety Design Basis for License Application'' (NSDB) (BSC 2005). Further, SSCs credited with performing safe functions are classified as ITS. In turn, performance confirmation for these SSCs is sought through the use of consensus code and standards. The purpose of this study is to identify applicable codes and standards for the waste package (WP) transporter and transport locomotive ITS SSCs. Further, this study will form the basis for selection and the extent of applicability of each code and standard. This study is based on the design development completed for License Application only. Accordingly, identification of ITS SSCs beyond those defined within the NSDB are based on designs that may be subject to further development during detail design. Furthermore, several design alternatives may still be under consideration to satisfy certain safety functions, and that final selection will not be determined until further design development has occurred. Therefore, for completeness, throughout this study alternative designs currently under consideration will be discussed. Further, the results of this study will be subject to evaluation as part of a follow-on gap analysis study. Based on the results of this study the gap analysis will evaluate each code and standard to ensure each ITS performance requirement is fully satisfied. When a performance requirement is not fully satisfied a ''gap'' is highlighted. Thereafter, the study will identify supplemental requirements to augment the code or standard to meet performance requirements. Further, the gap analysis will identify non-standard areas of the design that will be subject to a Development Plan. Non-standard components and

  8. The Assessment of a Tutoring Program to Meet CAS Standards Using a SWOT Analysis and Action Plan

    Science.gov (United States)

    Fullmer, Patricia

    2009-01-01

    This article summarizes the use of SWOT (Strengths, Weaknesses, Opportunities, and Threats) analysis and subsequent action planning as a tool of self-assessment to meet CAS (Council for the Advancement of Standards in Higher Education) requirements for systematic assessment. The use of the evaluation results to devise improvements to increase the…

  9. [Study on emission standard system of air pollutants].

    Science.gov (United States)

    Jiang, Mei; Zhang, Guo-Ning; Zhang, Ming-Hui; Zou, Lan; Wei, Yu-Xia; Ren, Chun

    2012-12-01

    Scientific and reasonable emission standard system of air pollutants helps to systematically control air pollution, enhance the protection of the atmospheric environment effect and improve the overall atmospheric environment quality. Based on the study of development, situation and characteristics of national air pollutants emission standard system, the deficiencies of system were pointed out, which were not supportive, harmonious and perfect, and the improvement measures of emission standard system were suggested.

  10. The development and standardization of Self-assessment for Hearing Screening of the Elderly

    Directory of Open Access Journals (Sweden)

    Kim G

    2016-06-01

    Full Text Available Gibbeum Kim,1 Wondo Na,1 Gungu Kim,1 Woojae Han,2 Jinsook Kim2 1Department of Speech Pathology and Audiology, Hallym University Graduate School, Chuncheon, Republic of Korea; 2Division of Speech Pathology and Audiology, Research Institute of Audiology and Speech Pathology, College of Natural Sciences, Hallym Universtiy, Chuncheon, Republic of Korea Purpose: The present study aimed to develop and standardize a screening tool for elderly people who wish to check for themselves their level of hearing loss. Methods: The Self-assessment for Hearing Screening of the Elderly (SHSE consisted of 20 questions based on the characteristics of presbycusis using a five-point scale: seven questions covered general issues related to sensorineural hearing loss, seven covered hearing difficulty under distracting listening conditions, two covered hearing difficulty with fast-rated speech, and four covered the working memory function during communication. To standardize SHSE, 83 elderly participants took part in the study: 25 with normal hearing, and 22, 23, and 13 with mild, moderate, and moderate-to-severe sensorineural hearing loss, respectively, according to their hearing sensitivity. All were retested 3 weeks later using the same questionnaire to confirm its reliability. In addition, validity was assessed using various hearing tests such as a sentence test with background noise, a time-compressed speech test, and a digit span test. Results: SHSE and its subcategories showed good internal consistency. SHSE and its subcategories demonstrated high test–retest reliability. A high correlation was observed between the total scores and pure-tone thresholds, which indicated gradually increased SHSE scores of 42.24%, 55.27%, 66.61%, and 78.15% for normal hearing, mild, moderate, and moderate-to-severe groups, respectively. With regard to construct validity, SHSE showed a high negative correlation with speech perception scores in noise and a moderate negative

  11. An agenda for assessing and improving conservation impacts of sustainability standards in tropical agriculture.

    Science.gov (United States)

    Milder, Jeffrey C; Arbuthnot, Margaret; Blackman, Allen; Brooks, Sharon E; Giovannucci, Daniele; Gross, Lee; Kennedy, Elizabeth T; Komives, Kristin; Lambin, Eric F; Lee, Audrey; Meyer, Daniel; Newton, Peter; Phalan, Ben; Schroth, Götz; Semroc, Bambi; Van Rikxoort, Henk; Zrust, Michal

    2015-04-01

    Sustainability standards and certification serve to differentiate and provide market recognition to goods produced in accordance with social and environmental good practices, typically including practices to protect biodiversity. Such standards have seen rapid growth, including in tropical agricultural commodities such as cocoa, coffee, palm oil, soybeans, and tea. Given the role of sustainability standards in influencing land use in hotspots of biodiversity, deforestation, and agricultural intensification, much could be gained from efforts to evaluate and increase the conservation payoff of these schemes. To this end, we devised a systematic approach for monitoring and evaluating the conservation impacts of agricultural sustainability standards and for using the resulting evidence to improve the effectiveness of such standards over time. The approach is oriented around a set of hypotheses and corresponding research questions about how sustainability standards are predicted to deliver conservation benefits. These questions are addressed through data from multiple sources, including basic common information from certification audits; field monitoring of environmental outcomes at a sample of certified sites; and rigorous impact assessment research based on experimental or quasi-experimental methods. Integration of these sources can generate time-series data that are comparable across sites and regions and provide detailed portraits of the effects of sustainability standards. To implement this approach, we propose new collaborations between the conservation research community and the sustainability standards community to develop common indicators and monitoring protocols, foster data sharing and synthesis, and link research and practice more effectively. As the role of sustainability standards in tropical land-use governance continues to evolve, robust evidence on the factors contributing to effectiveness can help to ensure that such standards are designed and

  12. Environmental assessment for the electric and hybrid vehicle demonstration project, performance standards and financial incentives

    Energy Technology Data Exchange (ETDEWEB)

    LaBelle, S. J.

    1978-10-01

    The assessment is concerned with the impacts of the demonstration of electric and hybrid vehicles acquired to fulfill certain requirements of the Electric and Hybrid Vehicle Research, Development, and Demonstration Act, PL 94-413 as amended. The financial incentives programs and vehicle performance standards associated with the demonstration are also covered. Not included is an assessment of the long term effects of EHV commercialization and of the research and development program being carried out simultaneously with the demonstration, also in response to PL 94-413. These federal actions will be included in a programmatic environmental assessment scheduled for completion in FY 79.

  13. Measuring Primary Students' Graph Interpretation Skills Via a Performance Assessment: A case study in instrument development

    Science.gov (United States)

    Peterman, Karen; Cranston, Kayla A.; Pryor, Marie; Kermish-Allen, Ruth

    2015-11-01

    This case study was conducted within the context of a place-based education project that was implemented with primary school students in the USA. The authors and participating teachers created a performance assessment of standards-aligned tasks to examine 6-10-year-old students' graph interpretation skills as part of an exploratory research project. Fifty-five students participated in a performance assessment interview at the beginning and end of a place-based investigation. Two forms of the assessment were created and counterbalanced within class at pre and post. In situ scoring was conducted such that responses were scored as correct versus incorrect during the assessment's administration. Criterion validity analysis demonstrated an age-level progression in student scores. Tests of discriminant validity showed that the instrument detected variability in interpretation skills across each of three graph types (line, bar, dot plot). Convergent validity was established by correlating in situ scores with those from the Graph Interpretation Scoring Rubric. Students' proficiency with interpreting different types of graphs matched expectations based on age and the standards-based progression of graphs across primary school grades. The assessment tasks were also effective at detecting pre-post gains in students' interpretation of line graphs and dot plots after the place-based project. The results of the case study are discussed in relation to the common challenges associated with performance assessment. Implications are presented in relation to the need for authentic and performance-based instructional and assessment tasks to respond to the Common Core State Standards and the Next Generation Science Standards.

  14. Postnatal Psychosocial Assessment and Clinical Decision-Making, a Descriptive Study.

    Science.gov (United States)

    Sims, Deborah; Fowler, Cathrine

    2018-05-18

    The aim of this study is to describe experienced child and family health nurses' clinical decision-making during a postnatal psychosocial assessment. Maternal emotional wellbeing in the postnatal year optimises parenting and promotes infant development. Psychosocial assessment potentially enables early intervention and reduces the risk of a mental disorder occurring during this time of change. Assessment accuracy, and the interventions used are determined by the standard of nursing decision-making. A qualitative methodology was employed to explore decision-making behaviour when conducting a postnatal psychosocial assessment. This study was conducted in an Australian early parenting organisation. Twelve experienced child and family health nurses were interviewed. A detailed description of a postnatal psychosocial assessment process was obtained using a critical incident technique. Template analysis was used to determine the information domains the nurses accessed, and content analysis was used to determine the nurses' thinking strategies, to make clinical decisions from this assessment. The nurses described 24 domains of information and used 17 thinking strategies, in a variety of combinations. The four information domains most commonly used were parenting, assessment tools, women-determined issues and sleep. The seven thinking strategies most commonly used were searching for information, forming relationships between the information, recognising a pattern, drawing a conclusion, setting priorities, providing explanations for the information and judging the value of the information. The variety and complexity of the clinical decision-making involved in postnatal psychosocial assessment confirms that the nurses use information appropriately and within their scope of nursing practice. The standard of clinical decision-making determines the results of the assessment and the optimal access to care. Knowledge of the information domains and the decision-making strategies

  15. Mission-Driven Expected Impact: Assessing Scholarly Output for 2013 Association to Advance Collegiate Schools of Business Standards

    Science.gov (United States)

    Goulet, Laurel R.; Lopes, Kevin J.; White, John Bryan

    2016-01-01

    As of the 2016-2017 academic year, all schools undergoing Association to Advance Collegiate Schools of Business accreditation will be assessed on the new standards that were ratified in 2013, which include the assessment of the impact of portfolios of intellectual contributions. The authors discuss key ideas underlying a business school's research…

  16. States' Flexibility Waiver Plans for Alternate Assessments Based on Alternate Achievement Standards (AA-AAS). Synthesis Report 96

    Science.gov (United States)

    Lazarus, Sheryl S.; Edwards, Lynn M.; Thurlow, Martha L.; Hodgson, Jennifer R.

    2014-01-01

    All states have alternate assessments based on alternate achievement standards (AA-AAS) for students with the most significant cognitive disabilities. For accountability purposes, the Elementary and Secondary Education Act (ESEA) allows up to 1% of students to be counted as proficient with this assessment option. In 2011 the U.S. Department of…

  17. Preservation Study for Ultra-Dilute VX Standards | Science ...

    Science.gov (United States)

    Report Lawrence Livermore National Laboratory (LLNL) supplies ultra-dilute (10 µg/mL) chemical warfare agent (CWA) standards to the Environmental Response Laboratory Network (ERLN) laboratories to allow the use of authentic standards to assist in analyses required for a remediation event involving CWAs. For this reason, it is important to collect data regarding the shelf-lives of these standards. The instability has the potential to impact quality control in regional ERLN laboratories, resulting in data that are difficult to interpret. Thus, this study investigated the use of chemical stabilizers to increase the shelf-life of VX standards. VX standards with long shelf-lives are desirable, as long shelf-life would significantly reduce the costs associated with synthesizing and resupplying the ERLN laboratories with VX.

  18. CASE STUDIES ON THE ASSESSMENT OF A REAL ESTATE IN TOURISM BY APPLYING THE 2017 PROPERTY VALUATION STANDARDS AS COMPARED TO 2016 GOODS VALUATION STANDARDS

    Directory of Open Access Journals (Sweden)

    ENEA CONSTANTIN

    2017-12-01

    Full Text Available By means of evaluation, in the Romanian legislation, is the value estimation activity, materialized in a document, called an evaluation report, carried out in accordance with the standards specific to this activity and with professional ethics, by an authorized evaluator. By law, the competent authority to organize, coordinate and authorize the evaluation activity in Romania is the National Association of Authorized Assessors in Romania (ANEVAR or the Association, as an autonomous legal entity, Authorized evaluators are part of it. Due to the dynamic nature of the profession of assessor, the Romanian legislation and other professions with an impact on evaluation, evaluation standards require periodic review. The Standards Collection, 2017, is called the 2017 Property Valuation Standards and will enter into force on May 1, 2017. The structure of the standards of the previous edition has been retained in this edition.

  19. Reviving common standards in point-count surveys for broad inference across studies

    Science.gov (United States)

    Matsuoka, Steven M.; Mahon, C. Lisa; Handel, Colleen M.; Solymos, Peter; Bayne, Erin M.; Fontaine, Patricia C.; Ralph, C.J.

    2014-01-01

    We revisit the common standards recommended by Ralph et al. (1993, 1995a) for conducting point-count surveys to assess the relative abundance of landbirds breeding in North America. The standards originated from discussions among ornithologists in 1991 and were developed so that point-count survey data could be broadly compared and jointly analyzed by national data centers with the goals of monitoring populations and managing habitat. Twenty years later, we revisit these standards because (1) they have not been universally followed and (2) new methods allow estimation of absolute abundance from point counts, but these methods generally require data beyond the original standards to account for imperfect detection. Lack of standardization and the complications it introduces for analysis become apparent from aggregated data. For example, only 3% of 196,000 point counts conducted during the period 1992-2011 across Alaska and Canada followed the standards recommended for the count period and count radius. Ten-minute, unlimited-count-radius surveys increased the number of birds detected by >300% over 3-minute, 50-m-radius surveys. This effect size, which could be eliminated by standardized sampling, was ≥10 times the published effect sizes of observers, time of day, and date of the surveys. We suggest that the recommendations by Ralph et al. (1995a) continue to form the common standards when conducting point counts. This protocol is inexpensive and easy to follow but still allows the surveys to be adjusted for detection probabilities. Investigators might optionally collect additional information so that they can analyze their data with more flexible forms of removal and time-of-detection models, distance sampling, multiple-observer methods, repeated counts, or combinations of these methods. Maintaining the common standards as a base protocol, even as these study-specific modifications are added, will maximize the value of point-count data, allowing compilation and

  20. A test-bed modeling study for wave resource assessment

    Science.gov (United States)

    Yang, Z.; Neary, V. S.; Wang, T.; Gunawan, B.; Dallman, A.

    2016-02-01

    Hindcasts from phase-averaged wave models are commonly used to estimate standard statistics used in wave energy resource assessments. However, the research community and wave energy converter industry is lacking a well-documented and consistent modeling approach for conducting these resource assessments at different phases of WEC project development, and at different spatial scales, e.g., from small-scale pilot study to large-scale commercial deployment. Therefore, it is necessary to evaluate current wave model codes, as well as limitations and knowledge gaps for predicting sea states, in order to establish best wave modeling practices, and to identify future research needs to improve wave prediction for resource assessment. This paper presents the first phase of an on-going modeling study to address these concerns. The modeling study is being conducted at a test-bed site off the Central Oregon Coast using two of the most widely-used third-generation wave models - WaveWatchIII and SWAN. A nested-grid modeling approach, with domain dimension ranging from global to regional scales, was used to provide wave spectral boundary condition to a local scale model domain, which has a spatial dimension around 60km by 60km and a grid resolution of 250m - 300m. Model results simulated by WaveWatchIII and SWAN in a structured-grid framework are compared to NOAA wave buoy data for the six wave parameters, including omnidirectional wave power, significant wave height, energy period, spectral width, direction of maximum directionally resolved wave power, and directionality coefficient. Model performance and computational efficiency are evaluated, and the best practices for wave resource assessments are discussed, based on a set of standard error statistics and model run times.

  1. Assessing FDG-PET diagnostic accuracy studies to develop recommendations for clinical use in dementia.

    Science.gov (United States)

    Boccardi, Marina; Festari, Cristina; Altomare, Daniele; Gandolfo, Federica; Orini, Stefania; Nobili, Flavio; Frisoni, Giovanni B

    2018-04-30

    FDG-PET is frequently used as a marker of synaptic damage to diagnose dementing neurodegenerative disorders. We aimed to adapt the items of evidence quality to FDG-PET diagnostic studies, and assess the evidence available in current literature to assist Delphi decisions for European recommendations for clinical use. Based on acknowledged methodological guidance, we defined the domains, specific to FDG-PET, required to assess the quality of evidence in 21 literature searches addressing as many Population Intervention Comparison Outcome (PICO) questions. We ranked findings for each PICO and fed experts making Delphi decisions for recommending clinical use. Among the 1435 retrieved studies, most lacked validated measures of test performance, an adequate gold standard, and head-to-head comparison of FDG-PET and clinical diagnosis, and only 58 entered detailed assessment. Only two studies assessed the accuracy of the comparator (clinical diagnosis) versus any kind of gold-/reference-standard. As to the index-test (FDG-PET-based diagnosis), an independent gold-standard was available in 24% of the examined papers; 38% used an acceptable reference-standard (clinical follow-up); and 38% compared FDG-PET-based diagnosis only to baseline clinical diagnosis. These methodological limitations did not allow for deriving recommendations from evidence. An incremental diagnostic value of FDG-PET versus clinical diagnosis or lack thereof cannot be derived from the current literature. Many of the observed limitations may easily be overcome, and we outlined them as research priorities to improve the quality of current evidence. Such improvement is necessary to outline evidence-based guidelines. The available data were anyway provided to expert clinicians who defined interim recommendations.

  2. Orally disintegrating and oral standard olanzapine tablets similarly elevate the homeostasis model assessment of insulin resistance index and plasma triglyceride levels in 12 healthy men: a randomized crossover study.

    Science.gov (United States)

    Vidarsdottir, Solrun; Vlug, Pauline; Roelfsema, Ferdinand; Frölich, Marijke; Pijl, Hanno

    2010-09-01

    Treatment with olanzapine is associated with obesity, diabetes mellitus, and dyslipidemia. Reports have indicated that orally disintegrating tablets (ODT) cause less weight gain than oral standard tablets (OST). The aim of this study was to compare the effect of short-term treatment with these 2 distinct olanzapine formulations on glucose and lipid metabolism in healthy men. Twelve healthy men (mean ± SEM age: 25.1 ± 5.5 years) received olanzapine ODT (10 mg od, 8 days), olanzapine OST (10 mg od, 8 days), or no intervention in a randomized crossover design. At breakfast and dinner, glucose, insulin, free fatty acids (FFA), and triglyceride concentrations were measured at 10-minute intervals from 30 minutes prior to 2 hours after ingestion of standard meals. Leptin and adiponectin concentrations were measured at 20- and 30-minute intervals, respectively, between 0000h-1200h. Physical activity was assessed with an accelerometer. Fuel oxidation was measured in fasting condition by indirect calorimetry. The study was conducted from April 2006 through September 2006. Treatment with olanzapine ODT and OST equally elevated the homeostasis model assessment of insulin resistance (HOMA-IR) (P = .005). At breakfast, both formulations equally increased fasting and postprandial triglyceride concentrations (P = .013 and P = .005, respectively) while decreasing fasting and postprandial FFA concentrations (P = .004 and P = .009, respectively). Body weight, body composition, physical activity, or fuel oxidation did not differ between treatment modalities. Eight days of treatment with both olanzapine formulations similarly increased HOMA-IR and triglyceride concentrations and decreased FFA concentrations in response to standard meals without affecting anthropometrics or physical activity. These data suggest that olanzapine hampers insulin action via mechanistic routes other than body adiposity or physical inactivity. controlled-trials.com. Identifier: ISRCTN17632637. © Copyright

  3. The Relationship between Students' Performance on Conventional Standardized Mathematics Assessments and Complex Mathematical Modeling Problems

    Science.gov (United States)

    Kartal, Ozgul; Dunya, Beyza Aksu; Diefes-Dux, Heidi A.; Zawojewski, Judith S.

    2016-01-01

    Critical to many science, technology, engineering, and mathematics (STEM) career paths is mathematical modeling--specifically, the creation and adaptation of mathematical models to solve problems in complex settings. Conventional standardized measures of mathematics achievement are not structured to directly assess this type of mathematical…

  4. Assessing the efficacy of the healthy eating and lifestyle programme (HELP compared with enhanced standard care of the obese adolescent in the community: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Christie Deborah

    2011-11-01

    Full Text Available Abstract Background The childhood obesity epidemic is one of the foremost UK health priorities. Childhood obesity tracks into adult life and places individuals at considerable risk for diabetes, cardiovascular disease, liver disease and other morbidities. There is widespread need for paediatric lifestyle programmes as change may be easier to accomplish in childhood than later in life. Study Design/Method The study will evaluate the management of adolescent obesity by conducting a Medical Research Council complex intervention phase III efficacy randomised clinical trial of the Healthy Eating Lifestyle Programme within primary care. The study tests a community delivered multi-component intervention designed for adolescents developed from best practice as identified by National Institute for Health and Clinical Excellence. The hospital based pilot reduced body mass index and improved health-related quality of life. Subjects will be individually randomised to receiving either the Healthy Eating Lifestyle Programme (12 fortnightly family sessions or enhanced standard care. Baseline and follow up assessments will be undertaken blind to allocation status. A health economic evaluation is also being conducted. 200 obese young people (13-17 years, body mass index > 98th centile for age and sex will be recruited from primary care within the greater London area. The primary hypothesis is that a motivational and solution-focused family-based weight management programme delivered over 6 months is more efficacious in reducing body mass index in obese adolescents identified in the community than enhanced standard care. The primary outcome will be body mass index at the end of the intervention, adjusted for baseline body mass index, age and sex. The secondary hypothesis is that the Healthy Eating Lifestyle Programme is more efficacious in improving quality of life and psychological function and reducing waist circumference and cardiovascular risk factors in

  5. Reduced-dose chest CT with 3D automatic exposure control vs. standard chest CT: Quantitative assessment of emphysematous changes in smokers’ lung parenchyma

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Yamazaki, Youichi; Matsumoto, Keiko; Onishi, Yumiko; Takenaka, Daisuke; Yoshikawa, Takeshi; Nishio, Mizuho; Matsumoto, Sumiaki; Murase, Kenya; Nishimura, Yoshihiro

    2012-01-01

    Objectives: To determine the capability of reduced-dose chest CT with three-dimensional (3D) automatic exposure control (AEC) on quantitative assessment of emphysematous change in smoker’ lung parenchyma, compared to standard chest CT. Methods: Twenty consecutive smoker patients (mean age 62.8 years) underwent CT examinations using a standard protocol (150 mAs) and a protocol with 3D-AEC. In this study, the targeted standard deviations number was set to 160. For quantitative assessment of emphysematous change in lung parenchyma in each subject using the standard protocol, a percentage of voxels less than −950 HU in the lung (%LAA −950 ) was calculated. The 3D-AEC protocol's %LAA was computed from of voxel percentages under selected threshold CT value. The differences of radiation doses between these two protocols were evaluated, and %LAAs −950 was compared with the 3D-AEC protocol %LAAs. Results: Mean dose length products were 780.2 ± 145.5 mGy cm (standard protocol), and 192.0 ± 95.9 (3D-AEC protocol). There was significant difference between them (paired Student's t test, p −950 and 3D-AEC protocol %LAAs. In adopting the feasible threshold CT values of the 3D-AEC protocol, the 3D-AEC protocol %LAAs were significantly correlated with %LAAs −950 (r = 0.98, p < 0.001) and limits of agreement from Bland–Altman analysis was 0.52 ± 4.3%. Conclusions: Changing threshold CT values demonstrated that reduced-dose chest CT with 3D-AEC can substitute for the standard protocol in assessments of emphysematous change in smoker’ lung parenchyma.

  6. Assessment of ECISS draft standard for derivation of high temperature proof strength values

    Energy Technology Data Exchange (ETDEWEB)

    Linde, L.; Sandstroem, R.

    1996-03-01

    New European material standards are under development and modern data evaluation techniques must be able to supply these standards with accurate design values. A draft standard for the derivation of high temperature proof strength values has been proposed. This standard (EDS) has been used to calculate strength values for six steels; one unalloyed steel, one 12 % Cr steel and four austenitic stainless steels. Although large data sets were available, it was not possible to satisfy the requirement in the EDS of 80 % temperature coverage in the proof strength data for several steels. It suggests that temperature coverage specified in the EDS is unrealistically high. Due to the limited number of heats satisfying the temperature coverage requirements for each steel, the statistical error in the derived values exceeds 10-20 % which must be considered as unacceptably high. Instead it is recommended that the full data sets are used irrespective of temperature coverage. The variation of proof strength values represented by the analysed heats did not cover the corresponding variation in the larger data set available. This was the case even for the steel where 16 heats satisfied the temperature coverage requirement. Thus a limited number of heats can not be expected to be a good representation of more complete data sets. This has the consequence that absolute strength values can not be derived without access to a standardised proof strength at room temperature. Two derivation methods investigated in this report are both based on the ISO 2605/III procedure for proof strength assessments at elevated temperature. Method I and II use an essentially temperature independent and temperature dependent reduction term respectively. The methods have been assessed by the same data sets for the six steels. One or both methods gave satisfactory results for most of the investigated steels. Presented results are based on work carried out in ECISS TC22 WG1. 17 refs, 20 figs, 7 tabs.

  7. Setting Performance Standards for Technical and Nontechnical Competence in General Surgery.

    Science.gov (United States)

    Szasz, Peter; Bonrath, Esther M; Louridas, Marisa; Fecso, Andras B; Howe, Brett; Fehr, Adam; Ott, Michael; Mack, Lloyd A; Harris, Kenneth A; Grantcharov, Teodor P

    2017-07-01

    The objectives of this study were to (1) create a technical and nontechnical performance standard for the laparoscopic cholecystectomy, (2) assess the classification accuracy and (3) credibility of these standards, (4) determine a trainees' ability to meet both standards concurrently, and (5) delineate factors that predict standard acquisition. Scores on performance assessments are difficult to interpret in the absence of established standards. Trained raters observed General Surgery residents performing laparoscopic cholecystectomies using the Objective Structured Assessment of Technical Skill (OSATS) and the Objective Structured Assessment of Non-Technical Skills (OSANTS) instruments, while as also providing a global competent/noncompetent decision for each performance. The global decision was used to divide the trainees into 2 contrasting groups and the OSATS or OSANTS scores were graphed per group to determine the performance standard. Parametric statistics were used to determine classification accuracy and concurrent standard acquisition, receiver operator characteristic (ROC) curves were used to delineate predictive factors. Thirty-six trainees were observed 101 times. The technical standard was an OSATS of 21.04/35.00 and the nontechnical standard an OSANTS of 22.49/35.00. Applying these standards, competent/noncompetent trainees could be discriminated in 94% of technical and 95% of nontechnical performances (P < 0.001). A 21% discordance between technically and nontechnically competent trainees was identified (P < 0.001). ROC analysis demonstrated case experience and trainee level were both able to predict achieving the standards with an area under the curve (AUC) between 0.83 and 0.96 (P < 0.001). The present study presents defensible standards for technical and nontechnical performance. Such standards are imperative to implementing summative assessments into surgical training.

  8. Development of an accident consequence assessment code for evaluating site suitability of light- and heavy-water reactors based on the Korean Technical standards

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Won Tae; Jeong, Hae Sung; Jeong, Hyo Joon; Kil, A Reum; Kim, Eun Han; Han, Moon Hee [Nuclear Environment Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    Methodologies for a series of radiological consequence assessments show a distinctive difference according to the design principles of the original nuclear suppliers and their technical standards to be imposed. This is due to the uncertainties of the accidental source term, radionuclide behavior in the environment, and subsequent radiological dose. Both types of PWR and PHWR are operated in Korea. However, technical standards for evaluating atmospheric dispersion have been enacted based on the U.S. NRC's positions regardless of the reactor types. For this reason, it might cause a controversy between the licensor and licensee of a nuclear power plant. It was modelled under the framework of the NRC Regulatory Guide 1.145 for light-water reactors, reflecting the features of heavy-water reactors as specified in the Canadian National Standard and the modelling features in MACCS2, such as atmospheric diffusion coefficient, ground deposition, surface roughness, radioactive plume depletion, and exposure from ground deposition. An integrated accident consequence assessment code, ACCESS (Accident Consequence Assessment Code for Evaluating Site Suitability), was developed by taking into account the unique regulatory positions for reactor types under the framework of the current Korean technical standards. Field tracer experiments and hand calculations have been carried out for validation and verification of the models. The modelling approaches of ACCESS and its features are introduced, and its applicative results for a hypothetical accidental scenario are comprehensively discussed. In an applicative study, the predicted results by the light-water reactor assessment model were higher than those by other models in terms of total doses.

  9. Evaluation of the ISO standard 11063 DNA extraction procedure for assessing soil microbial abundance and community structure.

    Directory of Open Access Journals (Sweden)

    Pierre Plassart

    Full Text Available Soil DNA extraction has become a critical step in describing microbial biodiversity. Historically, ascertaining overarching microbial ecological theories has been hindered as independent studies have used numerous custom and commercial DNA extraction procedures. For that reason, a standardized soil DNA extraction method (ISO-11063 was previously published. However, although this ISO method is suited for molecular tools such as quantitative PCR and community fingerprinting techniques, it has only been optimized for examining soil bacteria. Therefore, the aim of this study was to assess an appropriate soil DNA extraction procedure for examining bacterial, archaeal and fungal diversity in soils of contrasting land-use and physico-chemical properties. Three different procedures were tested: the ISO-11063 standard; a custom procedure (GnS-GII; and a modified ISO procedure (ISOm which includes a different mechanical lysis step (a FastPrep ®-24 lysis step instead of the recommended bead-beating. The efficacy of each method was first assessed by estimating microbial biomass through total DNA quantification. Then, the abundances and community structure of bacteria, archaea and fungi were determined using real-time PCR and terminal restriction fragment length polymorphism approaches. Results showed that DNA yield was improved with the GnS-GII and ISOm procedures, and fungal community patterns were found to be strongly dependent on the extraction method. The main methodological factor responsible for differences between extraction procedure efficiencies was found to be the soil homogenization step. For integrative studies which aim to examine bacteria, archaea and fungi simultaneously, the ISOm procedure results in higher DNA recovery and better represents microbial communities.

  10. Family Medicine Maternity Care Call to Action: Moving Toward National Standards for Training and Competency Assessment.

    Science.gov (United States)

    Magee, Susanna R; Eidson-Ton, W Suzanne; Leeman, Larry; Tuggy, Michael; Kim, Thomas O; Nothnagle, Melissa; Breuner, Joseph; Loafman, Mark

    2017-03-01

    Maternity care is an integral part of family medicine, and the quality and cost-effectiveness of maternity care provided by family physicians is well documented. Considering the population health perspective, increasing the number of family physicians competent to provide maternity care is imperative, as is working to overcome the barriers discouraging maternity care practice. A standard that clearly defines maternity care competency and a systematic set of tools to assess competency levels could help overcome these barriers. National discussions between 2012 and 2014 revealed that tools for competency assessment varied widely. These discussions resulted in the formation of a workgroup, culminating in a Family Medicine Maternity Care Summit in October 2014. This summit allowed for expert consensus to describe three scopes of maternity practice, draft procedural and competency assessment tools for each scope, and then revise the tools, guided by the Family Medicine and OB/GYN Milestones documents from the respective residency review committees. The summit group proposed that achievement of a specified number of procedures completed should not determine competency; instead, a standardized competency assessment should take place after a minimum number is performed. The traditionally held required numbers for core procedures were reassessed at the summit, and the resulting consensus opinion is proposed here. Several ways in which these evaluation tools can be disseminated and refined through the creation of a learning collaborative across residency programs is described. The summit group believed that standardization in training will more clearly define the competencies of family medicine maternity care providers and begin to reduce one of the barriers that may discourage family physicians from providing maternity care.

  11. Application of Standardized Precipitation Index to assess meteorological drought in Bangladesh

    Directory of Open Access Journals (Sweden)

    Md. Anarul H. Mondol

    2016-09-01

    Full Text Available Bangladesh is one of the vulnerable countries of the world for natural disasters. Drought is one of the common and severe calamities in Bangladesh that causes immense suffering to people in various ways. The present research has been carried out to examine the frequency of meteorological droughts in Bangladesh using the long-term rainfall data of 30 meteorological observatories covering the period of 1948–2011. The study uses the highly effective Standardized Precipitation Index (SPI for drought assessment in Bangladesh. By assessing the meteorological droughts and the history of meteorological droughts of Bangladesh, the spatial distributions of meteorological drought indices were also analysed. The spatial and temporal changes in meteorological drought and changes in different years based on different SPI month intervals were analysed. The results indicate that droughts were a normal and recurrent feature and it occurred more or less all over the country in virtually all climatic regions of the country. As meteorological drought depends on only rainfall received in an area, anomaly of rainfall is the main cause of drought. Bangladesh experienced drought in the years 1950, 1951, 1953, 1954, 1957, 1958, 1960, 1961, 1962, 1963, 1965, 1966, 1967 and 1971 before independence and after independence Bangladesh has experienced droughts in the years 1972, 1973, 1975, 1979, 1980, 1983, 1985, 1992, 1994, 1995, 2002, 2004, 2006, 2009 and 2011 during the period 1948–2011. The study indicated that Rajshahi and its surroundings, in the northern regions and Jessore and its surroundings areas, the island Bhola and surrounding regions, in the south-west region, were vulnerable. In the Sylhet division, except Srimongal, the areas were not vulnerable but the eastern southern sides of the districts Chittagong, Rangamati, Khagrachhari, Bandarban and Teknaf were vulnerable. In the central regions, the districts of Mymensingh and Faridpur were more vulnerable

  12. Mapping the Association of College and Research Libraries information literacy framework and nursing professional standards onto an assessment rubric.

    Science.gov (United States)

    Willson, Gloria; Angell, Katelyn

    2017-04-01

    The authors developed a rubric for assessing undergraduate nursing research papers for information literacy skills critical to their development as researchers and health professionals. We developed a rubric mapping six American Nurses Association professional standards onto six related concepts of the Association of College & Research Libraries (ACRL) Framework for Information Literacy for Higher Education. We used this rubric to evaluate fifty student research papers and assess inter-rater reliability. Students tended to score highest on the "Information Has Value" dimension and lowest on the "Scholarship as Conversation" dimension. However, we found a discrepancy between the grading patterns of the two investigators, with inter-rater reliability being "fair" or "poor" for all six rubric dimensions. The development of a rubric that dually assesses information literacy skills and maps relevant disciplinary competencies holds potential. This study offers a template for a rubric inspired by the ACRL Framework and outside professional standards. However, the overall low inter-rater reliability demands further calibration of the rubric. Following additional norming, this rubric can be used to help students identify the key information literacy competencies that they need in order to succeed as college students and future nurses. These skills include developing an authoritative voice, determining the scope of their information needs, and understanding the ramifications of their information choices.

  13. Importance of Standardized DXA Protocol for Assessing Physique Changes in Athletes.

    Science.gov (United States)

    Nana, Alisa; Slater, Gary J; Hopkins, Will G; Halson, Shona L; Martin, David T; West, Nicholas P; Burke, Louise M

    2016-06-01

    The implications of undertaking DXA scans using best practice protocols (subjects fasted and rested) or a less precise but more practical protocol in assessing chronic changes in body composition following training and a specialized recovery technique were investigated. Twenty-one male cyclists completed an overload training program, in which they were randomized to four sessions per week of either cold water immersion therapy or control groups. Whole-body DXA scans were undertaken with best practice protocol (Best) or random activity protocol (Random) at baseline, after 3 weeks of overload training, and after a 2-week taper. Magnitudes of changes in total, lean and fat mass from baseline-overload, overload-taper and baseline-taper were assessed by standardization (Δmean/SD). The standard deviations of change scores for total and fat-free soft tissue mass (FFST) from Random scans (2-3%) were approximately double those observed in the Best (1-2%), owing to extra random errors associated with Random scans at baseline. There was little difference in change scores for fat mass. The effect of cold water immersion therapy on baseline-taper changes in FFST was possibly harmful (-0.7%; 90% confidence limits ±1.2%) with Best scans but unclear with Random scans (0.9%; ±2.0%). Both protocols gave similar possibly harmful effects of cold water immersion therapy on changes in fat mass (6.9%; ±13.5% and 5.5%; ±14.3%, respectively). An interesting effect of cold water immersion therapy on training-induced changes in body composition might have been missed with a less precise scanning protocol. DXA scans should be undertaken with Best.

  14. Evaluation of online carbon isotope dilution mass spectrometry for the purity assessment of synthetic peptide standards

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, Sergio Cueto; Ruiz Encinar, Jorge, E-mail: ruizjorge@uniovi.es; García Alonso, J. Ignacio, E-mail: jiga@uniovi.es

    2014-09-24

    Highlights: • Purity assessment of peptide standards applicable to any water soluble peptide. • Online {sup 13}C isotope dilution mass spectrometry. • Mass flow chromatogram from measured 44/45 isotope ratios. • Validation by the analysis of NIST 8327. - Abstract: We present a novel method for the purity assessment of peptide standards which is applicable to any water soluble peptide. The method is based on the online {sup 13}C isotope dilution approach in which the peptide is separated from its related impurities by liquid chromatography (LC) and the eluent is mixed post-column with a continuous flow of {sup 13}C-enriched sodium bicarbonate. An online oxidation step using sodium persulfate in acidic media at 99 °C provides quantitative oxidation to {sup 12}CO{sub 2} and {sup 13}CO{sub 2} respectively which is extracted to a gaseous phase with the help of a gas permeable membrane. The measurement of the isotope ratio 44/45 in the mass spectrometer allows the construction of the mass flow chromatogram. As the only species that is finally measured in the mass spectrometer is CO{sub 2}, the peptide content in the standard can be quantified, on the base of its carbon content, using a generic primary standard such as potassium hydrogen phthalate. The approach was validated by the analysis of a reference material (NIST 8327), and applied to the quantification of two commercial synthetic peptide standards. In that case, the results obtained were compared with those obtained using alternative methods, such as amino acid analysis and ICP-MS. The results obtained proved the value of the method for the fast, accurate and precise mass purity assignment of synthetic peptide standards.

  15. Implications of Common Core State Standards on the Social Studies

    Science.gov (United States)

    Kenna, Joshua L.; Russell, William B., III.

    2014-01-01

    Social studies teachers have often been on the outside looking in during much of the era billed as the standards-based educational reform (SBER), but with the adoption and implementation of the Common Core State Standards (CCSS), social studies teachers seem to have been invited back inside. Yet, how will the standards impact social studies…

  16. Can the Movement Assessment Battery for Children-Test Be the "Gold Standard" for the Motor Assessment of Children with Developmental Coordination Disorder?

    Science.gov (United States)

    Venetsanou, Fotini; Kambas, Antonis; Ellinoudis, Theodoros; Fatouros, Ioannis; Giannakidou, Dimitra; Kourtessis, Thomas

    2011-01-01

    Developmental Coordination Disorder (DCD) is an important risk factor in the development of children that can have a significant academic and social impact. This reinforces the need for its timely identification using appropriate assessment methods and accurate screening tests. The commonly used standardized motor test for the DCD identification…

  17. The role of food standards on international trade: assessing the Brazilian beef chain

    Directory of Open Access Journals (Sweden)

    Luciana Marques Vieira

    2006-01-01

    Full Text Available The purpose of this paper is to identify how Brazilian beef managers have responded to a rapid expansion and intensification of standards for beef exports. This issue relates to how some Brazilian beef exporters are strategically repositioning themselves in the supply chains. The literature of this study reviews global chain governance and international standards. The method uses case studies consisting of six medium and large scale beef exporters who export fresh beef to the European Union. The main findings describe the kinds of governance that stimulate upgrading and transferral of the best practices and, consequently, full compliance with mandatory standards. This study suggests that standards do matter for companies trying to increase international competitiveness. These results contribute an understanding of the Brazilian beef chain, and also of other supply chains coping with demanding and changing international markets. Managerial implications show the challengesfacing Brazilian beef exporters in their efforts to sustain exports to the European Union and how they are using chain governance to improve their compliance with international standards and increase competitiveness.

  18. Using the Nursing Culture Assessment Tool (NCAT) in Long-Term Care: An Update on Psychometrics and Scoring Standardization.

    Science.gov (United States)

    Kennerly, Susan; Heggestad, Eric D; Myers, Haley; Yap, Tracey L

    2015-07-29

    An effective workforce performing within the context of a positive cultural environment is central to a healthcare organization's ability to achieve quality outcomes. The Nursing Culture Assessment Tool (NCAT) provides nurses with a valid and reliable tool that captures the general aspects of nursing culture. This study extends earlier work confirming the tool's construct validity and dimensionality by standardizing the scoring approach and establishing norm-referenced scoring. Scoring standardization provides a reliable point of comparison for NCAT users. NCAT assessments support nursing's ability to evaluate nursing culture, use results to shape the culture into one that supports change, and advance nursing's best practices and care outcomes. Registered nurses, licensed practical nurses, and certified nursing assistants from 54 long-term care facilities in Kentucky, Nevada, North Carolina, and Oregon were surveyed. Confirmatory factor analysis yielded six first order factors forming the NCAT's subscales (Expectations, Behaviors, Teamwork, Communication, Satisfaction, Commitment) (Comparative Fit Index 0.93) and a second order factor-The Total Culture Score. Aggregated facility level comparisons of observed group variance with expected random variance using rwg(J) statistics is presented. Normative scores and cumulative rank percentages and how the NCAT can be used in implementing planned change are provided.

  19. Understanding Standards and Assessment Policy in Science Education: Relating and Exploring Variations in Policy Implementation by Districts and Teachers in Wisconsin

    Science.gov (United States)

    Anderson, Kevin John Boyett

    Current literature shows that many science teachers view policies of standards-based and test-based accountability as conflicting with research-based instruction in science education. With societal goals of improving scientific literacy and using science to spur economic growth, improving science education policy becomes especially important. To understand perceived influences of science education policy, this study looked at three questions: 1) How do teachers perceive state science standards and assessment and their influence on curriculum and instruction? 2) How do these policy perspectives vary by district and teacher level demographic and contextual differences? 3) How do district leaders' interpretations of and efforts within these policy realms relate to teachers' perceptions of the policies? To answer these questions, this study used a stratified sample of 53 districts across Wisconsin, with 343 middle school science teachers responding to an online survey; science instructional leaders from each district were also interviewed. Survey results were analyzed using multiple regression modeling, with models generally predicting 8-14% of variance in teacher perceptions. Open-ended survey and interview responses were analyzed using a constant comparative approach. Results suggested that many teachers saw state testing as limiting use of hands-on pedagogy, while standards were seen more positively. Teachers generally held similar views of the degree of influence of standards and testing regardless of their experience, background in science, credentials, or grade level taught. District SES, size and past WKCE scores had some limited correlations to teachers' views of policy, but teachers' perceptions of district policies and leadership consistently had the largest correlation to their views. District leadership views of these state policies correlated with teachers' views. Implications and future research directions are provided. Keywords: science education, policy

  20. The role of framing effect in assessment of quality of life according to standard gambling theory

    OpenAIRE

    Songul Cinaroglu

    2015-01-01

    Measuring health outcomes includes risk and uncertainty. Quality of life assessment in health care has two main properties one is they are personal, the other is they are reflecting personal preferences. Because of patient preferences includes risk and uncertainty standard gambling theory used which is one of the quantitative techniques for assessment of patient preferences. Framing effect which is based on social psychology, shows that positive and negative framed information effects decisio...

  1. Evaluation of Life-Cycle Assessment Studies of Chinese Cement Production: Challenges and Opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Hongyou; Masanet, Eric; Price, Lynn

    2009-05-29

    The use of life-cycle assessment (LCA) to understand the embodied energy, environmental impacts, and potential energy-savings of manufactured products has become more widespread among researchers in recent years. This paper reviews recent LCA studies in the cement industry in China and in other countries and provides an assessment of the methodology used by the researchers compared to ISO LCA standards (ISO 14040:2006, ISO 14044:2006, and ISO/TR 14048:2002). We evaluate whether the authors provide information on the intended application, targeted audience, functional unit, system boundary, data sources, data quality assessment, data disaggregation and other elements, and draw conclusions regarding the level of adherence to ISO standards for the papers reviewed. We found that China researchers have gained much experience during last decade, but still have room for improvement in establishing boundaries, assessing data quality, identifying data sources, and explaining limitations. The paper concludes with a discussion of directions for future LCA research in China.

  2. Assessing and improving the quality of modeling : a series of empirical studies about the UML

    NARCIS (Netherlands)

    Lange, C.F.J.

    2007-01-01

    Assessing and Improving the Quality of Modeling A Series of Empirical Studies about the UML This thesis addresses the assessment and improvement of the quality of modeling in software engineering. In particular, we focus on the Unified Modeling Language (UML), which is the de facto standard in

  3. Assessing the standard Molybdenum projector augmented wave VASP potentials

    Energy Technology Data Exchange (ETDEWEB)

    Mattsson, Ann E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Multi-Scale Science

    2014-07-01

    Density Functional Theory (DFT) based Equation of State (EOS) construction is a prominent part of Sandia’s capabilities to support engineering sciences. This capability is based on augmenting experimental data with information gained from computational investigations, especially in those parts of the phase space where experimental data is hard, dangerous, or expensive to obtain. A key part of the success of the Sandia approach is the fundamental science work supporting the computational capability. Not only does this work enhance the capability to perform highly accurate calculations but it also provides crucial insight into the limitations of the computational tools, providing high confidence in the results even where results cannot be, or have not yet been, validated by experimental data. This report concerns the key ingredient of projector augmented-wave (PAW) potentials for use in pseudo-potential computational codes. Using the tools discussed in SAND2012-7389 we assess the standard Vienna Ab-initio Simulation Package (VASP) PAWs for Molybdenum.

  4. Assessing the Believability of Standardized Patients Trained to Portray Communication Disorders

    Science.gov (United States)

    Burns, Michael I.; Struijk, Jennie; Herron, Lindsay; Mach, Helen; Yorkston, Kathryn

    2017-01-01

    Purpose The purpose of this study was to evaluate the believability of standardized patients portraying individuals with communication disorders as part of a larger study in which standardized patients help train medical and allied health students about communication disorders. Method Two women portrayed persons with aphasia, and 2 men depicted persons with dysarthria associated with Parkinson's disease. Two stakeholder groups rated believability. Speech-language pathologists rated believability of videos online. Persons with aphasia rated aphasia videos during in-person sessions with the researchers. Results Targeted believability was 80 or higher (0–100 scale; 0 = not at all believable, 100 = very believable). For speech-language pathologist raters, average ratings met the target for the portrayals of the aphasia characteristics of word-finding problems, agrammaticism, nonverbal communication, and overall portrayal but not for auditory comprehension problems. Targets for the portrayals were met for the dysarthria characteristics of reduced speech movements, reduced loudness, reduced intonation, flat affect, and overall portrayal but not for speech rate. Ratings for different standardized patients portraying the same case were not significantly different from each other on most characteristics. Ratings from persons with aphasia were highly variable. Conclusion Standardized patients who do not have communication disorders can portray disorder characteristics in a believable manner. PMID:28595263

  5. Research Review: Test-retest reliability of standardized diagnostic interviews to assess child and adolescent psychiatric disorders: a systematic review and meta-analysis.

    Science.gov (United States)

    Duncan, Laura; Comeau, Jinette; Wang, Li; Vitoroulis, Irene; Boyle, Michael H; Bennett, Kathryn

    2018-02-19

    A better understanding of factors contributing to the observed variability in estimates of test-retest reliability in published studies on standardized diagnostic interviews (SDI) is needed. The objectives of this systematic review and meta-analysis were to estimate the pooled test-retest reliability for parent and youth assessments of seven common disorders, and to examine sources of between-study heterogeneity in reliability. Following a systematic review of the literature, multilevel random effects meta-analyses were used to analyse 202 reliability estimates (Cohen's kappa = ҡ) from 31 eligible studies and 5,369 assessments of 3,344 children and youth. Pooled reliability was moderate at ҡ = .58 (CI 95% 0.53-0.63) and between-study heterogeneity was substantial (Q = 2,063 (df = 201), p reliability varied across informants for specific types of psychiatric disorder (ҡ = .53-.69 for parent vs. ҡ = .39-.68 for youth) with estimates significantly higher for parents on attention deficit hyperactivity disorder, oppositional defiant disorder and the broad groupings of externalizing and any disorder. Reliability was also significantly higher in studies with indicators of poor or fair study methodology quality (sample size reliability of SDIs and the usefulness of these tools in both clinical and research contexts. Potential remedies include the introduction of standardized study and reporting requirements for reliability studies, and exploration of other approaches to assessing and classifying child and adolescent psychiatric disorder. © 2018 Association for Child and Adolescent Mental Health.

  6. Impact of European standard EN15251 in the energy certification of services buildings-A Portuguese study case

    International Nuclear Information System (INIS)

    Alexandre, J.L.; Freire, A.; Teixeira, A.M.; Silva, M.; Rouboa, A.

    2011-01-01

    In Europe, about 40% of the energy is consumed in buildings, more than by industry or transport. However, there is a great potential for energy savings in this field, often at little cost. A new European directive and several European standards, including the comfort standard EN15251, were created to develop comfortable and efficient buildings. This paper presents the interaction of this specific standard with the application of energy efficiency regulations. In order to evaluate the impact of the EN15251 application in commercial buildings, a case study was analyzed using the dynamic simulation software TRNSYS-The Transient Energy System Simulation Tool. The building was set according to the standard conditions specified by the national regulation, and the assessment of comfort requirements of EN15251 was verified. It was found that the current comfort requirements of the Portuguese regulation are not sufficient to achieve by themselves the comfort categories specified in the EN15251. About 55% of the comfort hours could not be assured. Furthermore, reaching the main comfort requirements (temperature/fresh air rates) of the EN15251 does not lead directly to the assessment of the corresponding categories. Results showed that the building stayed one comfort category behind from the desired when the correspondent operative temperatures were secured. On the other hand, it was found possible to achieve the comfort categories by increasing the operative temperature ranges, imposed by the standard, about 1 deg. C. This has a negative consequence, which is the increment of energy consumption. However, there is a large room for maneuver to reduce this consumption into acceptable levels according to the EPBD. - Highlights: → We study the interaction of European standard with energy efficiency regulations. → We evaluate the impact of the EN15251 application in commercial buildings. → Buildings were set according to the standards specified by the national regulation.

  7. Assessing cultural validity in standardized tests in stem education

    Science.gov (United States)

    Gassant, Lunes

    This quantitative ex post facto study examined how race and gender, as elements of culture, influence the development of common misconceptions among STEM students. Primary data came from a standardized test: the Digital Logic Concept Inventory (DLCI) developed by Drs. Geoffrey L. Herman, Michael C. Louis, and Craig Zilles from the University of Illinois at Urbana-Champaign. The sample consisted of a cohort of 82 STEM students recruited from three universities in Northern Louisiana. Microsoft Excel and the Statistical Package for the Social Sciences (SPSS) were used for data computation. Two key concepts, several sub concepts, and 19 misconceptions were tested through 11 items in the DLCI. Statistical analyses based on both the Classical Test Theory (Spearman, 1904) and the Item Response Theory (Lord, 1952) yielded similar results: some misconceptions in the DLCI can reliably be predicted by the Race or the Gender of the test taker. The research is significant because it has shown that some misconceptions in a STEM discipline attracted students with similar ethnic backgrounds differently; thus, leading to the existence of some cultural bias in the standardized test. Therefore the study encourages further research in cultural validity in standardized tests. With culturally valid tests, it will be possible to increase the effectiveness of targeted teaching and learning strategies for STEM students from diverse ethnic backgrounds. To some extent, this dissertation has contributed to understanding, better, the gap between high enrollment rates and low graduation rates among African American students and also among other minority students in STEM disciplines.

  8. Fusion reactor design studies: standard accounts for cost estimates

    International Nuclear Information System (INIS)

    Schulte, S.C.; Willke, T.L.; Young, J.R.

    1978-05-01

    The fusion reactor design studies--standard accounts for cost estimates provides a common format from which to assess the economic character of magnetically confined fusion reactor design concepts. The format will aid designers in the preparation of design concept costs estimates and also provide policymakers with a tool to assist in appraising which design concept may be economically promising. The format sets forth a categorization and accounting procedure to be used when estimating fusion reactor busbar energy cost that can be easily and consistently applied. Reasons for developing the procedure, explanations of the procedure, justifications for assumptions made in the procedure, and the applicability of the procedure are described in this document. Adherence to the format when evaluating prospective fusion reactor design concepts will result in the identification of the more promising design concepts thus enabling the fusion power alternatives with better economic potential to be quickly and efficiently developed

  9. MRI of the temporo-mandibular joint: which sequence is best suited to assess the cortical bone of the mandibular condyle? A cadaveric study using micro-CT as the standard of reference.

    Science.gov (United States)

    Karlo, Christoph A; Patcas, Raphael; Kau, Thomas; Watzal, Helmut; Signorelli, Luca; Müller, Lukas; Ullrich, Oliver; Luder, Hans-Ulrich; Kellenberger, Christian J

    2012-07-01

    To determine the best suited sagittal MRI sequence out of a standard temporo-mandibular joint (TMJ) imaging protocol for the assessment of the cortical bone of the mandibular condyles of cadaveric specimens using micro-CT as the standard of reference. Sixteen TMJs in 8 human cadaveric heads (mean age, 81 years) were examined by MRI. Upon all sagittal sequences, two observers measured the cortical bone thickness (CBT) of the anterior, superior and posterior portions of the mandibular condyles (i.e. objective analysis), and assessed for the presence of cortical bone thinning, erosions or surface irregularities as well as subcortical bone cysts and anterior osteophytes (i.e. subjective analysis). Micro-CT of the condyles was performed to serve as the standard of reference for statistical analysis. Inter-observer agreements for objective (r = 0.83-0.99, P < 0.01) and subjective (κ = 0.67-0.88) analyses were very good. Mean CBT measurements were most accurate, and cortical bone thinning, erosions, surface irregularities and subcortical bone cysts were best depicted on the 3D fast spoiled gradient echo recalled sequence (3D FSPGR). The most reliable MRI sequence to assess the cortical bone of the mandibular condyles on sagittal imaging planes is the 3D FSPGR sequence. MRI may be used to assess the cortical bone of the TMJ. • Depiction of cortical bone is best on 3D FSPGR sequences. • MRI can assess treatment response in patients with TMJ abnormalities.

  10. The International Standards Organisation offshore structures standard

    International Nuclear Information System (INIS)

    Snell, R.O.

    1994-01-01

    The International Standards Organisation has initiated a program to develop a suite of ISO Codes and Standards for the Oil Industry. The Offshore Structures Standard is one of seven topics being addressed. The scope of the standard will encompass fixed steel and concrete structures, floating structures, Arctic structures and the site specific assessment of mobile drilling and accommodation units. The standard will use as base documents the existing recommended practices and standards most frequently used for each type of structure, and will develop them to incorporate best published and recognized practice and knowledge where it provides a significant improvement on the base document. Work on the Code has commenced under the direction of an internationally constituted sub-committee comprising representatives from most of the countries with a substantial offshore oil and gas industry. This paper outlines the background to the code and the format, content and work program

  11. Strategy for assessing occupational radiation monitoring data from many facilities for use in epidemiologic studies

    International Nuclear Information System (INIS)

    Strom, D.J.

    1984-01-01

    The process of transforming occupational radiation monitoring data into a form useful for epidemiology is called dose assessment. A review of previous dose assessment activities is done as a background for development of standard dose assessment procedures for use at many facilities. The scientific issues identified include the accuracy, precision, and comparability of doses over time and across facilities, the use of internal monitoring results; neutron quality factors; minimum detection limits; the quality and validity of data; and the impact of uncertainty in the exposure variable on misclassification of workers with respect to that variable. The standard dose assessment procedures developed address these issues, and include a method for determining what data are available and what form they are in, illustrated by application to 36 facilities in the US Department of Energy 5-Rem Study. The standard procedures are illustrated and tested on external and uranium monitoring results from the Y-12 Plant in Oak Ridge, Tennessee, where data permitted inferences of doses and variances to total body, skin, and lung, but not bone or kidney

  12. From the Margins to the Spotlight: Diverse Deaf and Hard of Hearing Student Populations and Standardized Assessment Accessibility

    Science.gov (United States)

    Cawthon, Stephanie

    2015-01-01

    Designing assessments and tests is one of the more challenging aspects of creating an accessible learning environment for students who are deaf or hard of hearing (DHH), particularly for deaf students with a disability (DWD). Standardized assessments are a key mechanism by which the educational system in the United States measures student…

  13. Interior Design Standards in the Secondary FCS Curriculum

    Science.gov (United States)

    Katz, Shana H.; Smith, Bettye P.

    2006-01-01

    This article deals with a study on interior design standards in the secondary FCS curriculum. This study assessed the importance FCS teachers placed on content standards in the interior design curriculum to help determine the amount of time and emphasis to place on the units within the courses. A cover letter and questionnaire were sent…

  14. Using standardized patients to assess the communication skills of graduating physicians for the comprehensive osteopathic medical licensing examination (COMLEX) level 2-performance evaluation (level 2-PE).

    Science.gov (United States)

    Weidner, Angela C; Gimpel, John R; Boulet, John R; Solomon, Mia

    2010-01-01

    Standardized patients can be trained to assess the communication and interpersonal skills of medical students and graduates. The purpose of this study is to present data to support the psychometric adequacy of the communication ratings provided by standardized patients. Using the data from testing of 3, 450 examinees over a 1-year period, a number of psychometric analyses were undertaken. These included a variance component analysis, the calculation of various validity coefficients, the comparison of communication ratings for select examinee cohorts and case characteristics, and the investigation of some potential sources of score invalidity. Communication skills scores are moderately correlated to other competencies (knowledge, skills) and may be influenced by candidate characteristics such as gender and English language proficiency. They are not dependant on the age of the examinees, the clinical case content, or the gender of the standardized patients. For a multistation assessment, a reasonably precise and valid estimate of a candidate's communication ability can be obtained from trained standardized patients.

  15. The Impact of Excluding Food Guarding from a Standardized Behavioral Canine Assessment in Animal Shelters

    Directory of Open Access Journals (Sweden)

    Heather Mohan-Gibbons

    2018-02-01

    Full Text Available Many shelters euthanize or restrict adoptions for dogs that exhibit food guarding while in the animal shelter. However, previous research showed that only half the dogs exhibiting food guarding during an assessment food guard in the home. So, dogs are often misidentified as future food guarders during shelter assessments. We examined the impact of shelters omitting food guarding assessments. Nine shelters conducted a two-month baseline period of assessing for food guarding followed by a two-month investigative period during which they omitted the food guarding assessment. Dogs that guarded their food during a standardized assessment were less likely to be adopted, had a longer shelter stay, and were more likely to be euthanized. When the shelters stopped assessing for food guarding, there was no significant difference in the rate of returns of food guarding dogs, even though more dogs were adopted because fewer were identified with food guarding behavior. Additionally, the number of injuries to staff, volunteers, and adopters was low (104 incidents from a total of 14,180 dogs and did not change when the food guarding assessment was omitted. These results support a recommendation that shelters discontinue the food guarding assessment.

  16. Standardized assessment of psychosocial factors and their influence on medically confirmed health outcomes in workers: a systematic review.

    Science.gov (United States)

    Rosário, Susel; Fonseca, João A; Nienhaus, Albert; da Costa, José Torres

    2016-01-01

    Previous studies of psychosocial work factors have indicated their importance for workers' health. However, to what extent health problems can be attributed to the nature of the work environment or other psychosocial factors is not clear. No previous systematic review has used inclusion criteria based on specific medical evaluation of work-related health outcomes and the use of validated instruments for the assessment of the psychosocial (work) environment. The aim of this systematic review is to summarize the evidence assessing the relationship between the psychosocial work environment and workers' health based on studies that used standardized and validated instruments to assess the psychosocial work environment and that focused on medically confirmed health outcomes. A systematic review of the literature was carried out by searching the databases PubMed, B-ON, Science Direct, Psycarticles, Psychology and Behavioral Sciences Collection and the search engine (Google Scholar) using appropriate words for studies published from 2004 to 2014. This review follows the recommendations of the Statement for Reporting Systematic Reviews (PRISMA). Studies were included in the review if data on psychosocial validated assessment method(s) for the study population and specific medical evaluation of health-related work outcome(s) were presented. In total, the search strategy yielded 10,623 references, of which 10 studies (seven prospective cohort and three cross-sectional) met the inclusion criteria. Most studies (7/10) observed an adverse effect of poor psychosocial work factors on workers' health: 3 on sickness absence, 4 on cardiovascular diseases. The other 3 studies reported detrimental effects on sleep and on disease-associated biomarkers. A more consistent effect was observed in studies of higher methodological quality that used a prospective design jointly with the use of validated instruments for the assessment of the psychosocial (work) environment and clinical

  17. A new customized fetal growth standard for African American women: the PRB/NICHD Detroit Study

    Science.gov (United States)

    Tarca, Adi L.; Romero, Roberto; Gudicha, Dereje W.; Erez, Offer; Hernandez-Andrade, Edgar; Yeo, Lami; Bhatti, Gaurav; Pacora, Percy; Maymon, Eli; Hassan, Sonia S.

    2018-01-01

    Background The assessment of fetal growth disorders requires a standard. Current nomograms for the assessment of fetal growth in African American women have been derived either from neonatal (rather than fetal) biometry data or have not been customized for maternal ethnicity, weight, height, parity, and fetal sex. Objective We sought to 1) develop a new customized fetal growth standard for African American mothers; and 2) compare such a standard to three existing standards for the classification of fetuses as small (SGA) or large (LGA) for gestational age. Study Design A retrospective cohort study included 4,183 women (4,001 African American and 182 Caucasian) from the Detroit metropolitan area who underwent ultrasound examinations between 14 and 40 weeks of gestation (the median number of scans per pregnancy was 5, interquartile range 3-7) and for whom relevant covariate data were available. Longitudinal quantile regression was used to build models defining the “normal” estimated fetal weight (EFW) centiles for gestational age in African American women, adjusted for maternal height, weight, parity, and fetal sex, and excluding pathologic factors with a significant effect on fetal weight. The resulting Perinatology Research Branch/Eunice Kennedy Shriver National Institute of Child Health and Human Development (hereinafter, PRB/NICHD) growth standard was compared to 3 other existing standards—the customized gestation-related optimal weight (GROW) standard; the Eunice Kennedy Shriver National Institute of Child Health and Human Development (hereinafter, NICHD) African American standard; and the multinational World Health Organization (WHO) standard—utilized to screen fetuses for SGA (90th centile) based on the last available ultrasound examination for each pregnancy. Results 1) First, the mean birthweight at 40 weeks was 133g higher for neonates born to Caucasian than to African American mothers and 150g higher for male than female neonates; maternal weight

  18. Development and validation of an observation tool for the assessment of nursing pain management practices in intensive care unit in a standardized clinical simulation setting.

    Science.gov (United States)

    Gosselin, Emilie; Bourgault, Patricia; Lavoie, Stephan; Coleman, Robin-Marie; Méziat-Burdin, Anne

    2014-12-01

    Pain management in the intensive care unit is often inadequate. There is no tool available to assess nursing pain management practices. The aim of this study was to develop and validate a measuring tool to assess nursing pain management in the intensive care unit during standardized clinical simulation. A literature review was performed to identify relevant components demonstrating optimal pain management in adult intensive care units and to integrate them in an observation tool. This tool was submitted to an expert panel and pretested. It was then used to assess pain management practice during 26 discrete standardized clinical simulation sessions with intensive care nurses. The Nursing Observation Tool for Pain Management (NOTPaM) contains 28 statements grouped into 8 categories, which are grouped into 4 dimensions: subjective assessment, objective assessment, interventions, and reassessment. The tool's internal consistency was calculated at a Cronbach's alpha of 0.436 for the whole tool; the alpha varies from 0.328 to 0.518 for each dimension. To evaluate the inter-rater reliability, intra-class correlation coefficient was used, which was calculated at 0.751 (p nurses' pain management in a standardized clinical simulation. The NOTPaM is the first tool created for this purpose. Copyright © 2014 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  19. States' Participation Guidelines for Alternate Assessments Based on Modified Academic Achievement Standards (AA-MAS) in 2010. Synthesis Report 82

    Science.gov (United States)

    Lazarus, Sheryl S.; Hodgson, Jennifer R.; Price, Lynn M.; Thurlow, Martha L.

    2011-01-01

    Federal legislation requires that all students participate in state accountability systems. Most students with disabilities participate in the regular assessment, with or without accommodations. Students with more significant cognitive disabilities participate in the Alternate Assessment based on Alternate Achievement Standards (AA-AAS). A few…

  20. Introduction of a new standardized assessment score of spine morphology in osteogenesis imperfecta

    International Nuclear Information System (INIS)

    Koerber, F.; Schulze Uphoff, U.; Koerber, S.; Maintz, D.; Schoenau, E.; Semler, O.

    2012-01-01

    Purpose: Osteogenesis imperfecta (OI) is a rare hereditary disease leading to multiple bone deformities and fractures. In the absence of causal therapy, a symptomatic approach is based on treatment with bisphosphonates and physiotherapy. The clinical and radiological manifestations vary. Therefore, standardization and quantification for an objective comparison, especially during therapy, are required. In this paper, radiological changes of the spine are quantified according to their clinical relevance to define a scoring system that transfers the morphological changes into a single value representing the severity of the disease. Materials and Methods: 268 lateral spine X-rays of 95 patients with OI (median age 5.6 years) were assessed. The findings were classified based on their clinical relevance. Results: The three criteria, vertebral compression, thoracolumbar kyphosis and deformity type, were quantified in a new grading system. Based on this, a 'severity classification' (1 to 5) was defined with implications for diagnostics and treatment. A mathematical formula that takes into account the three criteria and their correlations to clinical relevance, resulting in a 'severity score', was developed. Conclusion: 'Severity classification' and 'severity score' introduce a new concept for a standardized evaluation of spine X-rays in patients with OI. For both scientific and routine purposes, it provides the user with a simple and easy-to-handle tool for assessing and comparing different stages of severity prior to and during therapy with detailed accuracy. (orig.)

  1. Standardization of domestic human reliability analysis and experience of human reliability analysis in probabilistic safety assessment for NPPs under design

    International Nuclear Information System (INIS)

    Kang, D. I.; Jung, W. D.

    2002-01-01

    This paper introduces the background and development activities of domestic standardization of procedure and method for Human Reliability Analysis (HRA) to avoid the intervention of subjectivity by HRA analyst in Probabilistic Safety Assessment (PSA) as possible, and the review of the HRA results for domestic nuclear power plants under design studied by Korea Atomic Energy Research Institute. We identify the HRA methods used for PSA for domestic NPPs and discuss the subjectivity of HRA analyst shown in performing a HRA. Also, we introduce the PSA guidelines published in USA and review the HRA results based on them. We propose the system of a standard procedure and method for HRA to be developed

  2. Development of the private practice management standards for psychology.

    Science.gov (United States)

    Mathews, Rebecca; Stokes, David; Littlefield, Lyn; Collins, Leah

    2011-01-01

    This paper describes the process of developing a set of private practice management standards to support Australian psychologists and promote high quality services to the public. A review of the literature was conducted to identify management standards relevant to psychology, which were further developed in consultation with a panel of experts in psychology or in the development of standards. Forty-three psychologists in independent private practice took part in either a survey (n=22) to provide feedback on the relevance of, and their compliance with, the identified standards, or a 6-month pilot study (n=21) in which a web-based self-assessment instrument evaluating the final set of standards and performance indicators was implemented in their practice to investigate self-reported change in management procedures. The pilot study demonstrated good outcomes for practitioners when evaluation of compliance to the standards was operationalized in a self-assessment format. Study results are based on a small sample size. Nevertheless, relevance and utility of the standards was found providing an initial version of management standards that have relevance to the practice of psychology in Australia, along with a system for evaluating psychological service provision to ensure best practice in service delivery. © 2010 National Association for Healthcare Quality.

  3. Resource utilization after introduction of a standardized clinical assessment and management plan.

    Science.gov (United States)

    Friedman, Kevin G; Rathod, Rahul H; Farias, Michael; Graham, Dionne; Powell, Andrew J; Fulton, David R; Newburger, Jane W; Colan, Steven D; Jenkins, Kathy J; Lock, James E

    2010-01-01

    A Standardized Clinical Assessment and Management Plan (SCAMP) is a novel quality improvement initiative that standardizes the assessment and management of all patients who carry a predefined diagnosis. Based on periodic review of systemically collected data the SCAMP is designed to be modified to improve its own algorithm. One of the objectives of a SCAMP is to identify and reduce resource utilization and patient care costs. We retrospectively reviewed resource utilization in the first 93 arterial switch operation (ASO) SCAMP patients and 186 age-matched control ASO patients. We compared diagnostic and laboratory testing obtained at the initial SCAMP clinic visit and control patient visits. To evaluate the effect of the SCAMP over time, the number of clinic visits per patient year and echocardiograms per patient year in historical control ASO patients were compared to the projected rates for ASO SCAMP participants. Cardiac magnetic resonance imaging (MRI), stress echocardiogram, and lipid profile utilization were higher in the initial SCAMP clinic visit group than in age-matched control patients. Total echocardiogram and lung scan usage were similar. Chest X-ray and exercise stress testing were obtained less in SCAMP patients. ASO SCAMP patients are projected to have 0.5 clinic visits and 0.5 echocardiograms per year. Historical control patients had more clinic visits (1.2 vs. 0.5 visits/patient year, P<.01) and a higher echocardiogram rate (0.92 vs. 0.5 echocardiograms/patient year, P<.01) Implementation of a SCAMP may initially lead to increased resource utilization, but over time resource utilization is projected to decrease.

  4. Assessing Medical Students' Awareness of and Sensitivity to Diverse Health Beliefs Using a Standardized Patient Station.

    Science.gov (United States)

    Robins, Lynne S.; White, Casey B.; Alexander, Gwen L.; Gruppen, Larry D.; Grum, Cyril M.

    2001-01-01

    Assessed students' competence in addressing the health beliefs and cultural concerns of a standardized patient, an African American woman with diabetes, during a clinical interview. Found that minority students displayed greater competence in addressing the patient's concerns about altering culturally-based dietary behaviors; white students…

  5. Using open technical e-learning standards and service-orientation to support new forms of e-assessment

    NARCIS (Netherlands)

    Miao, Yongwu; Tattersall, Colin; Schoonenboom, Judith; Stevanov, Krassen; Aleksieva-Petrova, Adelina

    2007-01-01

    Miao, Y., Tattersall, C., Schoonenboom, J., Stevanov, K., & Aleksieva-Petrova, A. (2007). Using open technical e-learning standards and service-orientation to support new forms of e-assessment. In D. Griffiths, R. Koper & O. Liber (Eds.), Proceedings of the second TENCompetence Open Workshop on

  6. Standard for supply security. A minimum standard to guarantee the balance between electricity demand and supply for the long term

    International Nuclear Information System (INIS)

    Scheepers, M.J.J.; Van Werven, M.J.N.; Seebregts, A.J.; Poort, J.P.; De Nooij, M.; Baarsma, B.E.

    2004-05-01

    The development and use of a minimum reliability standard in the Dutch electricity market to guarantee an adequate balance between electricity demand and supply in the longer term are discussed. This standard can be based on the duration of a power outage and the related costs for society relative to the costs to prevent the power outage. The reliability standard can be translated in an adequacy standard when the reliability of foreign electricity supply to the Dutch market is taken into account. With a theoretical analysis and an assessment of the use of standards in foreign electricity markets and other sectors this study provides a survey of the use of standards in securing public interests. In electricity markets reliability standards can be used obligatory or only to inform market participants of the adequacy of supply preferred by consumers. If no standard is used, the market should rely on the economic incentives provided by contracts and liability. This study proposes to use a reliability standard for calculating the required generation capacity in an ex-ante market analysis using different future scenarios. On the basis of several market indicators, expected market developments can be monitored. Assessment of the market developments relative to the required generation capacity will give a signal to market participants with respect to the expected adequacy in the longer term (7 to 10 years). The assessment and the resulting signal should help to improve market transparency and assist producers, suppliers and consumers in their decisions towards an effective and efficient response on long-term market developments. Market monitoring results can be used by the government to take specific action, if necessary, to reduce barriers to invest. However, more general policy measures should not be linked to the monitoring results since this could provoke strategic behaviour [nl

  7. Gold standards and expert panels: a pulmonary nodule case study with challenges and solutions

    Science.gov (United States)

    Miller, Dave P.; O'Shaughnessy, Kathryn F.; Wood, Susan A.; Castellino, Ronald A.

    2004-05-01

    Comparative evaluations of reader performance using different modalities, e.g. CT with computer-aided detection (CAD) vs. CT without CAD, generally require a "truth" definition based on a gold standard. There are many situations in which a true invariant gold standard is impractical or impossible to obtain. For instance, small pulmonary nodules are generally not assessed by biopsy or resection. In such cases, it is common to use a unanimous consensus or majority agreement from an expert panel as a reference standard for actionability in lieu of the unknown gold standard for disease. Nonetheless, there are three major concerns about expert panel reference standards: (1) actionability is not synonymous with disease (2) it may be possible to obtain different conclusions about which modality is better using different rules (e.g. majority vs. unanimous consensus), and (3) the variability associated with the panelists is not formally captured in the p-values or confidence intervals that are generally produced for estimating the extent to which one modality is superior to the other. A multi-reader-multi-case (MRMC) receiver operating characteristic (ROC) study was performed using 90 cases, 15 readers, and a reference truth based on 3 experienced panelists. The primary analyses were conducted using a reference truth of unanimous consensus regarding actionability (3 out of 3 panelists). To assess the three concerns noted above: (1) additional data from the original radiology reports were compared to the panel (2) the complete analysis was repeated using different definitions of truth, and (3) bootstrap analyses were conducted in which new truth panels were constructed by picking 1, 2, or 3 panelists at random. The definition of the reference truth affected the results for each modality (CT with CAD and CT without CAD) considered by itself, but the effects were similar, so the primary analysis comparing the modalities was robust to the choice of the reference truth.

  8. Zimbabwe's Human Resources for health Information System (ZHRIS)-an assessment in the context of establishing a global standard.

    Science.gov (United States)

    Waters, Keith P; Zuber, Alexandra; Simbini, Tungamirirai; Bangani, Zwashe; Krishnamurthy, Ramesh S

    2017-04-01

    There have been numerous global calls to action to utilize human resources information systems (HRIS) to improve the availability and quality of data for strengthening the regulation and deployment of health workers. However, with no normative guidance in existence, the development of HRIS has been inconsistent and lacking in standardization, hindering the availability and use of data for health workforce planning and decision making (Riley et al., 2012). CDC and WHO partnered with the Ministry of Health in several countries to conduct HRIS functional requirements analyses and establish a Minimum Data Set (MDS) of elements essential for a global standard HRIS. As a next step, CDC advanced a study to examine the alignment of one of the HRIS it supports (in Zimbabwe) against this MDS. For this study, we created a new data collection and analysis tool to assess the extent to which Zimbabwe's CDC-supported HRIS was aligned with the WHO MDS. We performed systematic "gap analyses" in order to make prioritized recommendations for addressing the gaps, with the aim of improving the availability and quality of data on Zimbabwe's health workforce. The majority of the data elements outlined in the WHO MDS were present in the ZHRIS databases, though they were found to be missing various applicable elements. The lack of certain elements could impede functions such as health worker credential verification or equitable in-service training allocation. While the HRIS MDS treats all elements equally, our assessment revealed that not all the elements have equal significance when it comes to data utilization. Further, some of the HRIS MDS elements exceeded the current needs of regulatory bodies and the Ministry of Health and Child Care (MOHCC) in Zimbabwe. The preliminary findings of this study helped inspire the development of a more recent HRH Registry MDS subset, which is a shorter list of priority data elements recommended as a global standard for HRIS. The field-tested assessment

  9. Study on the Standard Establishment for the Integrity Assessment of Nuclear Fuel Cladding Materials

    Energy Technology Data Exchange (ETDEWEB)

    Kang, S-S; Kim, S-H; Jung, Y-K; Yang, C-Y; Kim, I-G; Choi, Y-H; Kim, H-J; Kim, M-W; Rho, B-H [KINS, Daejeon (Korea, Republic of)

    2008-02-15

    Fuel cladding material plays important role as a primary structure under the high temperature, high pressure and neutron environment of nuclear power plant. According to this environment, cladding material can be experienced several type aging phenomena including the neutron irradiation embrittlement. On the other hand, although the early nuclear power plant was designed to fitting into the 40MWd/KgU burn-up, the currently power plant intends to go to the high burn-up range. In this case, the safety criteria which was established at low burn-up needs to conform the applicability at the high burn-up. In this study, the safety criteria of fuel cladding material was reviewed to assess the cladding material integrity, and the material characteristics of cladding were reviewed. The current LOCA criterial was also reviewed, and the basic study for re-establishment of LOCA criteria was performed. The time concept safety criteria was also discussed to prevent the breakaway oxidation. Through the this study, safety issues will be produced and be helpful for integrity insurance of nuclear fuel cladding material. This report is the final report.

  10. Qualichem in vivo: a tool for assessing the quality of in vivo studies and its application for bisphenol A.

    Directory of Open Access Journals (Sweden)

    Laura Maxim

    Full Text Available In regulatory toxicology, quality assessment of in vivo studies is a critical step for assessing chemical risks. It is crucial for preserving public health studies that are considered suitable for regulating chemicals are robust. Current procedures for conducting quality assessments in safety agencies are not structured, clear or consistent. This leaves room for criticism about lack of transparency, subjective influence and the potential for insufficient protection provided by resulting safety standards. We propose a tool called "Qualichem in vivo" that is designed to systematically and transparently assess the quality of in vivo studies used in chemical health risk assessment. We demonstrate its use here with 12 experts, using two controversial studies on Bisphenol A (BPA that played an important role in BPA regulation in Europe. The results obtained with Qualichem contradict the quality assessments conducted by expert committees in safety agencies for both of these studies. Furthermore, they show that reliance on standardized guidelines to ensure scientific quality is only partially justified. Qualichem allows experts with different disciplinary backgrounds and professional experiences to express their individual and sometimes divergent views-an improvement over the current way of dealing with minority opinions. It provides a transparent framework for expressing an aggregated, multi-expert level of confidence in a study, and allows a simple graphical representation of how well the study integrates the best available scientific knowledge. Qualichem can be used to compare assessments of the same study by different health agencies, increasing transparency and trust in the work of expert committees. In addition, it may be used in systematic evaluation of in vivo studies submitted by industry in the dossiers that are required for compliance with the REACH Regulation. Qualichem provides a balanced, common framework for assessing the quality of

  11. [Humidification assessment of four heat and moisture exchanger filters according to ISO 9360: 2000 standard].

    Science.gov (United States)

    Lannoy, D; Décaudin, B; Resibois, J-P; Barrier, F; Wierre, L; Horrent, S; Batt, C; Moulront, S; Odou, P

    2008-02-01

    This work consisted of the assessment of humidification parameters and flow resistance for different heat and moisture exchanger filters (HMEF) used in intensive care unit. Four electrostatic HMEF were assessed: Hygrobac S (Tyco); Humidvent compact S (Teleflex); Hygrovent S/HME (Medisize-Dräger); Clear-Therm+HMEF (Intersurgical). Humidification parameters (loss of water weight, average absolute moisture [AAM], absolute variation of moisture) have been evaluated on a bench-test in conformity with the ISO 9360: 2000 standard, for 24h with the following ventilatory settings: tidal volume at 500 ml, respiratory rate at 15 c/min, and inspiration/expiration ratio at 1:1. The flow resistance of HMEFs assessed using the pressure drop method was measured before and after 24h of humidification for three increasing air flows of 30, 60, and 90 l/min. All the HMEFs allowed satisfactory level of humidification exceeding 30 mgH(2)O/l. The less powerful remained the Clear-Therm. Concerning HMEFs flow resistance, results showed a pressure drop slightly more important for the Hygrobac S filter as compared with other filters. This test showed differences between the HMEFs for both humidification and resistance parameters. When compared to the new version of the standards, HMEFs demonstrated their reliability. However, evolution of humidification and flow resistance characteristics over 24h showed a structural degradation of HMEFs, limiting their use over a longer period.

  12. Specification of Energy Assessment Methodologies to Satisfy ISO 50001 Energy Management Standard

    Science.gov (United States)

    Kanneganti, Harish

    Energy management has become more crucial for industrial sector as a way to lower their cost of production and in reducing their carbon footprint. Environmental regulations also force the industrial sector to increase the efficiency of their energy usage. Hence industrial sector started relying on energy management consultancies for improvements in energy efficiency. With the development of ISO 50001 standard, the entire energy management took a new dimension involving top level management and getting their commitment on energy efficiency. One of the key requirements of ISO 50001 is to demonstrate continual improvement in their (industry) energy efficiency. The major aim of this work is to develop an energy assessment methodology and reporting format to tailor the needs of ISO 50001. The developed methodology integrates the energy reduction aspect of an energy assessment with the requirements of sections 4.4.3 (Energy Review) to 4.4.6 (Objectives, Targets and Action Plans) in ISO 50001 and thus helping the facilities in easy implementation of ISO 50001.

  13. Two-Dimensional Cutting (TDC Vitrectome: In Vitro Flow Assessment and Prospective Clinical Study Evaluating Core Vitrectomy Efficiency versus Standard Vitrectome

    Directory of Open Access Journals (Sweden)

    Mitrofanis Pavlidis

    2016-01-01

    Full Text Available Purpose. To evaluate comparative aspiration flow performance and also vitrectomy operating time efficiency using a double-cutting open port vitreous cutting system incorporated in a two-dimensional cutting (TDC, DORC International vitrectome design versus standard vitreous cutter. Methods. In vitro investigations compared aspiration flow rates in artificial vitreous humor at varying cutter speeds and vacuum levels using a TDC vitrectome and a standard vitrectome across different aspiration pump systems. A prospective single-centre clinical study evaluated duration of core vitrectomy in 80 patients with macular pucker undergoing 25-gauge or 27-gauge vitrectomy using either a TDC vitrectome at 16,000 cuts per minute (cpm or standard single-cut vitrectome, combined with a Valve Timing intelligence (VTi pump system (EVA, DORC International. Results. Aspiration flow rates remained constant independent of TDC vitrectome cut rate, while flow rates decreased linearly at higher cutter speeds using a classic single-blade vitrectome. Mean duration of core vitrectomy surgeries using a TDC vitreous cutter system was significantly (p<0.001 shorter than the mean duration of core vitrectomy procedures using a single-cut vitrectome of the same diameter (reduction range, 34%–50%. Conclusion. Vitrectomy surgery performed using a TDC vitrectome was faster than core vitrectomy utilizing a standard single-action vitrectome at similar cut speeds.

  14. What influences assessors' internalised standards?

    International Nuclear Information System (INIS)

    Poole, C.; Boland, J.

    2016-01-01

    Purpose: The meaning assessors attach to assessment criteria during clinical placement is under-researched. While personal beliefs, values or expectations may influence judgements, there is scant evidence of how this manifests in a clinical attachment setting. This research explored the concept and source of internalised standards and how these may influence judgements. Methods: This study, within the constructivist paradigm, was informed by the principles of grounded theory. Seven radiation therapists, purposefully selected, were interviewed face-to-face using semi-structured interviews. The sample size allowed for the gathering of sufficient data for in-depth thematic analysis, using the functionality of CAQDAS (NVivo 9). Results: Radiation therapists' judgements when assessing students were influenced by their previous experience. They had different expectations of the appropriate standard for each criterion on students' assessment forms – relating to technical ability, clinical knowledge and attitude. They had their own set of values, or expectations which informed ‘internalised standards’ which influenced their judgements about student performance. Prior experience – as students and as qualified professionals – influenced these decisions. Conclusion: Assessment of students' performance may differ depending on the clinician conducting the assessment. Even where assessors are given the same criteria and training, this does not ensure reliability, as judgements are influenced by their internalised standards. This has implications for the design of more appropriate assessor training which recognises and addresses this phenomenon. These results will be of interest to radiation therapists, radiographers, medical educators, allied health professionals and any academic or professional body with responsibility for ensuring that we qualify competent practitioners. - Highlights: • Reliability of clinical assessment is of the upmost importance

  15. Nursing Home Self-assessment of Implementation of Emergency Preparedness Standards.

    Science.gov (United States)

    Lane, Sandi J; McGrady, Elizabeth

    2016-08-01

    Introduction Disasters often overwhelm a community's capacity to respond and recover, creating a gap between the needs of the community and the resources available to provide services. In the wake of multiple disasters affecting nursing homes in the last decade, increased focus has shifted to this vital component of the health care system. However, the long-term care sector has often fallen through the cracks in both planning and response. Problem Two recent reports (2006 and 2012) published by the US Department of Health and Human Services (DHHS), Office of Inspector General (OIG), elucidate the need for improvements in nursing homes' comprehensive emergency preparedness and response. The Center for Medicare and Medicaid Services (CMS) has developed an emergency preparedness checklist as a guidance tool and proposed emergency preparedness regulations. The purpose of this study was to evaluate the progress made in nursing home preparedness by determining the level of completion of the 70 tasks noted on the checklist. The study objectives were to: (1) determine the preparedness levels of nursing homes in North and South Carolina (USA), and (2) compare these findings with the 2012 OIG's report on nursing home preparedness to identify current gaps. A survey developed from the checklist of items was emailed to 418 North Carolina and 193 South Carolina nursing home administrators during 2014. One hundred seventeen were returned/"bounced back" as not received. Follow-up emails and phone calls were made to encourage participation. Sixty-three completed surveys and 32 partial surveys were received. Responses were compared to data obtained in a 2010 study to determine progress. Progress had been made in many of the overall planning and sheltering-in-place tasks, such as having contact information of local emergency managers as well as specifications for availability of potable water. Yet, gaps still persisted, especially in evacuation standards, interfacing with emergency

  16. Standardization of D2 lymphadenectomy and surgical quality control (KLASS-02-QC): a prospective, observational, multicenter study [NCT01283893

    International Nuclear Information System (INIS)

    Kim, Hyoung-Il; Hur, Hoon; Kim, Youn Nam; Lee, Hyuk-Joon; Kim, Min-Chan; Han, Sang-Uk; Hyung, Woo Jin

    2014-01-01

    Extended systemic lymphadenectomy (D2) is standard procedure for surgical treatment of advanced gastric cancer (AGC) although less extensive lymphadenectomy (D1) can be applied to early gastric cancer. Complete D2 lymphadenectomy is the mandatory procedure for studies that evaluate surgical treatment results of AGC. However, the actual extent of D2 lymphadenectomy varies among surgeons because of a lacking consensus on the anatomical definition of each lymph node station. This study is aimed to develop a consensus for D2 lymphadenectomy and also to qualify surgeons that can perform both laparoscopic and open D2 gastrectomy. This (KLASS-02-QC) is a prospective, observational, multicenter study to qualify the surgeons that will participate in the KLASS-02-RCT, which is a prospective, randomized, clinical trial comparing laparoscopic and open gastrectomy for AGC. Surgeons and reviewers participating in the study will be required to complete a questionnaire detailing their professional experience and specific gastrectomy surgical background/training, and the gastrectomy metrics of their primary hospitals. All surgeons must submit three laparoscopic and three open D2 gastrectomy videos, respectively. Each video will be allocated to five peer reviewers; thus each surgeon’s operations will be assessed by a total of 30 reviews. Based on blinded assessment of unedited videos by experts’ review, a separate review evaluation committee will decide whether or not the evaluated surgeon will participate in the KLASS-02-RCT. The primary outcome measure is each surgeon’s proficiency, as assessed by the reviewers based on evaluation criteria for completeness of D2 lymphadenectomy. We believe that our study for standardization of D2 lymphadenectomy and surgical quality control (KLASS-02-QC) will guarantee successful implementation of the subsequent KLASS-02-RCT study. After making consensus on D2 lymphadenectomy, we developed evaluation criteria for completeness of D2

  17. Using the Nursing Culture Assessment Tool (NCAT in Long-Term Care: An Update on Psychometrics and Scoring Standardization

    Directory of Open Access Journals (Sweden)

    Susan Kennerly

    2015-07-01

    Full Text Available An effective workforce performing within the context of a positive cultural environment is central to a healthcare organization’s ability to achieve quality outcomes. The Nursing Culture Assessment Tool (NCAT provides nurses with a valid and reliable tool that captures the general aspects of nursing culture. This study extends earlier work confirming the tool’s construct validity and dimensionality by standardizing the scoring approach and establishing norm-referenced scoring. Scoring standardization provides a reliable point of comparison for NCAT users. NCAT assessments support nursing’s ability to evaluate nursing culture, use results to shape the culture into one that supports change, and advance nursing’s best practices and care outcomes. Registered nurses, licensed practical nurses, and certified nursing assistants from 54 long-term care facilities in Kentucky, Nevada, North Carolina, and Oregon were surveyed. Confirmatory factor analysis yielded six first order factors forming the NCAT’s subscales (Expectations, Behaviors, Teamwork, Communication, Satisfaction, Commitment (Comparative Fit Index 0.93 and a second order factor—The Total Culture Score. Aggregated facility level comparisons of observed group variance with expected random variance using rwg(J statistics is presented. Normative scores and cumulative rank percentages and how the NCAT can be used in implementing planned change are provided.

  18. Improving the quality of maternal and neonatal care: the role of standard based participatory assessments.

    Directory of Open Access Journals (Sweden)

    Giorgio Tamburlini

    Full Text Available BACKGROUND: Gaps in quality of care are seriously affecting maternal and neonatal health globally but reports of successful quality improvement cycles implemented at large scale are scanty. We report the results of a nation-wide program to improve quality of maternal and neonatal hospital care in a lower-middle income country focusing on the role played by standard-based participatory assessments. METHODS: Improvements in the quality of maternal and neonatal care following an action-oriented participatory assessment of 19 areas covering the whole continuum from admission to discharge were measured after an average period of 10 months in four busy referral maternity hospitals in Uzbekistan. Information was collected by a multidisciplinary national team with international supervision through visit to hospital services, examination of medical records, direct observation of cases and interviews with staff and mothers. Scores (range 0 to 3 attributed to over 400 items and combined in average scores for each area were compared with the baseline assessment. RESULTS: Between the first and the second assessment, all four hospitals improved their overall score by an average 0.7 points out of 3 (range 0.4 to 1, i.e. by 22%. The improvements occurred in all main areas of care and were greater in the care of normal labor and delivery (+0.9, monitoring, infection control and mother and baby friendly care (+0.8 the role of the participatory action-oriented approach in determining the observed changes was estimated crucial in 6 out of 19 areas and contributory in other 8. Ongoing implementation of referral system and new classification of neonatal deaths impede the improved process of care to be reflected in current statistics. CONCLUSIONS: Important improvements in the quality of hospital care provided to mothers and newborn babies can be achieved through a standard-based action-oriented and participatory assessment and reassessment process.

  19. A light diet for a giant appetite: An assessment of China's fluorescent lamp standard

    International Nuclear Information System (INIS)

    Lin Jiang

    2005-01-01

    Lighting has been one of the fastest growing electric end uses in China over the last 20 years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting needs. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8-T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through energy efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's 2003 minimum efficiency standard for linear fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and greenhouse gas emissions

  20. An assessment of greenhouse gas emissions-weighted clean energy standards

    International Nuclear Information System (INIS)

    Coffman, Makena; Griffin, James P.; Bernstein, Paul

    2012-01-01

    This paper quantifies the relative cost-savings of utilizing a greenhouse gas emissions-weighted Clean Energy Standard (CES) in comparison to a Renewable Portfolio Standard (RPS). Using a bottom-up electricity sector model for Hawaii, this paper demonstrates that a policy that gives “clean energy” credit to electricity technologies based on their cardinal ranking of lifecycle GHG emissions, normalizing the highest-emitting unit to zero credit, can reduce the costs of emissions abatement by up to 90% in comparison to a typical RPS. A GHG emissions-weighted CES provides incentive to not only pursue renewable sources of electricity, but also promotes fuel-switching among fossil fuels and improved generation efficiencies at fossil-fired units. CES is found to be particularly cost-effective when projected fossil fuel prices are relatively low. - Highlights: ► Proposes a GHG Emissions-Weighted Clean Energy Standard (CES) mechanism. ► Compares CES to RPS using a case study of Hawaii. ► Finds CES is up to 90% more cost-effective as a GHG abatement tool.

  1. Standardization of figures and assessment procedures for DTM verticalaccuracy

    Directory of Open Access Journals (Sweden)

    Vittorio Casella

    2015-07-01

    Full Text Available Digital Terrain Models (DTMs are widely used in many sectors. They play a key role in hydrological risk prevention, risk mitigation and numeric simulations. This paper deals with two questions: (i when it is stated that a DTM has a given vertical accuracy, is this assertion univocal? (ii when DTM vertical accuracy is assessed by means of checkpoints, does their location influence results? First, the paper illustrates that two vertical accuracy definitions are conceivable: Vertical Accuracy at the Nodes (VAN, the average vertical distance between the model and the terrain, evaluated at the DTM's nodes and Vertical Accuracy at the interpolated Points (VAP, in which the vertical distance is evaluated at the generic points. These two quantities are not coincident and, when they are calculated for the same DTM, different numeric values are reached. Unfortunately, the two quantities are often interchanged, but this is misleading. Second, the paper shows a simulated example of a DTM vertical accuracy assessment, highlighting that the checkpoints’ location plays a key role: when checkpoints coincide with the DTM nodes, VAN is estimated; when checkpoints are randomly located, VAP is estimated, instead. Third, an in-depth, theoretical characterization of the two considered quantities is performed, based on symbolic computation, and suitable standardization coefficients are proposed. Finally, our discussion has a well-defined frame: it doesn't deal with all the items of the DTM vertical accuracy budget, which would require a much longer essay, but only with one, usually called fundamental vertical accuracy.

  2. A study of undue pain and surfing: using hierarchical criteria to assess website quality.

    Science.gov (United States)

    Lorence, Daniel; Abraham, Joanna

    2008-09-01

    In studies of web-based consumer health information, scant attention has been paid to the selective development of differential methodologies for website quality evaluation, or to selective grouping and analysis of specific ;domains of uncertainty' in healthcare. Our objective is to introduce a more refined model for website evaluation, and illustrate its application using assessment of websites within an area of ongoing medical uncertainty, back pain. In this exploratory technology assessment, we suggest a model for assessing these ;domains of uncertainty' within healthcare, using qualitative assessment of websites and hierarchical concepts. Using such a hierarchy of quality criteria, we review medical information provided by the most frequently accessed websites related to back pain. Websites are evaluated using standardized criteria, with results rated from the viewpoint of the consumer. Results show that standardization of quality rating across subjective content, and between commercial and niche search results, can provide a consumer-friendly dimension to health information.

  3. Social Studies Fresh Frontier for Standards

    Science.gov (United States)

    Gewertz, Catherine

    2011-01-01

    Feeling that social studies has been sidelined by a test-driven focus on math and English/language arts, subject-matter specialists from more than a dozen states met last week with representatives of content-area groups to brainstorm ways to improve academic standards in that subject. The two-day gathering in Charlotte, N.C., is the third convened…

  4. To Which Degree Does Sector Specific Standardization Make Life Cycle Assessments Comparable?—The Case of Global Warming Potential of Smartphones

    Directory of Open Access Journals (Sweden)

    Anders S. G. Andrae

    2014-11-01

    Full Text Available Here attributional life cycle assessments (LCAs for the same smartphone model are presented by two different organizations (Orange, OGE and Huawei, HuW and the effect of different modeling approach is analyzed. A difference of around 32% (29.6 kg and 39.2 kg for CO2e baseline scores is found using same study object and sector specific LCA standard, however, different metrics, emission intensities, and LCA software programs. The CO2e difference is reduced to 12% (29.9 kg and 33.5 kg when OGE use HuW metrics for use phase power consumption and total mass, and when HuW use OGE metrics for gold mass and silicon die area. Further, a probability test confirms that present baseline climate change results, for one specific study object modeled with two largely different and independent LCA modeling approaches, are comparable if both use the European Telecommunications Standard Institute (ETSI LCA standard. The general conclusion is that the ETSI LCA standard strongly facilitates comparable CC results for technically comparable smartphone models. Moreover, thanks to the reporting requirements of ETSI LCA standard, a clear understanding of the differences between LCA modeling approaches is obtained. The research also discusses the magnitude of the CO2e reduction potential in the life cycle of smartphones.

  5. Sustainability Performance of Scandinavian Corporations and their Value Chains assessed by UN Global Compact and Global Reporting Initiative standards - a way to identify superior performers?

    DEFF Research Database (Denmark)

    Kjærgaard, Thomas

    2014-01-01

    The purpose of this study was to introduce a combination of the two most adopted multi- stakeholder standards for sustainability reporting as an alternate framework for assessing sustainability performance in Scandinavian corporations. This novel approach leverages numeric measures on the criteria...

  6. Environmental assessment for the Consumer Products Efficiency Standards program

    Energy Technology Data Exchange (ETDEWEB)

    1980-05-23

    The Energy Policy and Conservation Act of 1975 as amended by the National Energy Conservation Policy Act of 1978, requires the DOE to prescribe energy efficiency standards for thirteen consumer products. The Consumer Products Efficiency Standards (CPES) program covers the following products: refrigerators and refrigerator-freezers; freezers;clothes dryers;water heaters; room air conditioners; home heating equipment (not including furnaces); kitchen ranges and ovens; central air conditioners (cooling and heat pumps); furnaces; dishwashers; television sets; clothes washers; and humidifiers and dehumidifiers. DOE is proposing two sets of standards for all thirteen consumer products: intermediate standards to become effective in 1981 for the first nine products and in 1982 for the second four products, and final standards to become effective in 1986 and 1987, respectively. The final standards are more restrictive than the intermediate standards and will provide manufacturers with the maximum time permitted under the Act to plan and develop extensive new lines of efficient consumer products. The final standards proposed by DOE require the maximum improvements in efficiency which are technologically feasible and economically justified, as required by Section 325(c) of EPCA. The thirteen consumer products account for approximately 90% of all the energy consumed in the nation's residences, or more than 20% of the nation's energy needs. Increases in the energy efficiency of these consumer products can help to narrow the gap between the nation's increasing demand for energy and decreasing supplies of domestic oil and natural gas. Improvements in the efficiency of consumer products can thus help to solve the nation's energy crisis.

  7. Implementation and evaluation of the International Electrotechnical Commission specification for tidal stream energy resource assessment: A case study

    International Nuclear Information System (INIS)

    Ramos, V.; Ringwood, John V.

    2016-01-01

    Highlights: • The utility of the International Electrotechnical Commission standards for tidal stream resource assessment were analysed. • The Orkney Region (N Scotland) was used as a case study. • A sensitivity analysis in terms of accuracy vs computational times was carried out for different mesh resolutions. • Modelling the operation of a tidal energy converter becomes essential for an appropriate estimation of the tidal resource. • Practical recommendations are proposed for future editions of the technical standard. - Abstract: Over the next decades, tidal stream energy aims to become a fully commercially viable energy source. For this purpose, complete knowledge regarding tidal stream resource assessment is essential. In this context, the International Electrotechnical Commission has developed a technical standard for the assessment of the tidal stream resource, “IEC 62600-201 TS: Marine energy - Wave, tidal and other water current converters - Part 201: Tidal energy resource assessment and characterisation”, offering a vast set of recommendations in the fields of data collection, numerical modelling, data analysis and reporting of the results with the purpose of standardising tidal stream resource characterisation. The standard divides resource assessments into two different classes: feasibility and layout design. The model setup procedure (mesh resolution, boundary conditions) and the computational effort required vary significantly from one class to another. For these reasons, the objective of the present work is to explore the proposed standard using the Orkney Region (N Scotland) as a case study. Overall, it was found that the standard works well, offering a detailed characterisation of the tidal resource; however, in order to improve its manageability, some aspects related to the grid resolution requirements and the approach to model a tidal energy converter could be revisited for future editions.

  8. Study on the standard architecture for geoinformation common services

    Science.gov (United States)

    Zha, Z.; Zhang, L.; Wang, C.; Jiang, J.; Huang, W.

    2014-04-01

    The construction of platform for geoinformation common services was completed or on going in in most provinces and cities in these years in China, and the platforms plays an important role in the economic and social activities. Geoinfromation and geoinfromation based services are the key issues in the platform. The standards on geoinormation common services play as bridges among the users, systems and designers of the platform. The standard architecture for geoinformation common services is the guideline for designing and using the standard system in which the standards integrated to each other to promote the development, sharing and services of geoinformation resources. To establish the standard architecture for geoinformation common services is one of the tasks of "Study on important standards for geonformation common services and management of public facilities in city". The scope of the standard architecture is defined, such as data or information model, interoperability interface or service, information management. Some Research work on the status of international standards of geoinormation common services in organization and countries, like ISO/TC 211, OGC and other countries or unions like USA, EU, Japan have done. Some principles are set up to evaluate the standard, such as availability, suitability and extensible ability. Then the development requirement and practical situation are analyzed, and a framework of the standard architecture for geoinformation common services are proposed. Finally, a summary and prospects of the geoinformation standards are made.

  9. Assessment of the Standardized Precipitation Index (SPI) in Tegal City, Central Java, Indonesia

    Science.gov (United States)

    Pramudya, Y.; Onishi, T.

    2018-03-01

    One of the adverse impacts of climate change is drought, which occurs more frequently in Tegal city, Indonesia. The application of drought index analysis is useful for drought assessment to consider adaptation and mitigation method in order to deal with climate change. By figuring out the level and duration of the drought. In order to analyze drought in the specific area, Standardized Precipitation Index (SPI) is an index to quantify the rainfall deficit for multiple timescales. In 2015, Indonesia experienced severe drought, which has not been analyzed, yet. Thus, it is important to assess a quantitative evaluation of the drought condition. The study shows that from all deficit periods, the most severe drought in duration and peak took place in 2015, with each drought index as follows: 1 month deficit or SPI-1 (-3.11) in 1985 (-2.51) in 2015, 3 month deficit or SPI-3 (-2.291) in 1995 (-1.82) in 2015, 6 month deficit or SPI-6 (-2.40) in 1997 and (-1.84) in 2015, 9 month deficit or SPI-9 (-1.12) in 2015, 12 month deficit or SPI-12 (-1.19) in 2015. The result underlines the potential that SPI exhibits in drought identification and the use of the rainfall strongly linked to drought relief policy and measure implementation in Tegal city.

  10. The Assessment Of The Level Of Management Control Standards Completion In Treasury Sector

    Directory of Open Access Journals (Sweden)

    Kulińska Ewa

    2015-06-01

    Full Text Available This paper concerns the rules of the functioning of management control standards used in the Treasury Control Office. Its purpose is to present research results conducted in the years 2013–2014 in Polish Treasury Control Offices. Obtained results are the effect of applying author’s model of the assessment of management control implementation. The research was conducted for management personnel and the rest of offices employees separately. Significant discrepancies between these two groups of respondents were indicated. Based on the results, the areas of deviation from expected level of management control standards were established and the areas where implementation of control mechanisms relying on increasing the supervision of board of directors over managers were indicated, providing permanent and efficient elements of managers supervision over subordinate employees and making purposes and tasks put on the Treasury Control Office for given year more precise and familiarization of employees and carrying out trainings and series of other corrective measures.

  11. Study of Standard Model processes with leptons of high transverse momentum with the ATLAS detector

    CERN Document Server

    Petridis, Andreas

    This PhD thesis has taken up various aspects in experimental particle physics by analyzing the first data of the ATLAS detector. The main subject of the thesis is the production cross section measurement of the ZZ process at sqrt{s} = 7 TeV of proton-proton collisions. In order to study this, the author has contributed to various topics, such as detector related issues, the study of standard candle processes and Monte Carlo studies. In specic, this thesis presents a detailed study for the improvement of the hit position and peaking time resolution of the CSCs with 0.6% and 0.4% relative errors respectively. This thesis has also contributed to the first Z inclusive cross section measurement at sqrt{s} = 7 TeV, by analyzing the first 316 nb-1 of data recorded by the Atlas detector. The Z->ll cross section measurement is used as a standard candle for detector performance assessment as well as for the tuning of theoretical predictions at the new energy regime. The fiducial and total cross sections have ...

  12. Studies and research concerning BNFP: cask handling equipment standardization

    International Nuclear Information System (INIS)

    McCreery, P.N.

    1980-10-01

    This report covers the activities of one of the sub-tasks within the Spent LWR Fuel Transportation Receiving, Handling, and Storage program. The sub-task is identified as Cask Handling Equipment Standardization. The objective of the sub-task specifies: investigate and identify opportunities for standardization of cask interface equipment. This study will examine the potential benefits of standardized yokes, decontamination barriers and special tools, and, to the extent feasible, standardized methods and software for handling the variety of casks presently available in the US fleet. The result of the investigations is a compilation of reports that are related by their common goal of reducing cask turnaround time

  13. Assessment of histological response of paediatric bone sarcomas using FDG PET in comparison to morphological volume measurement and standardized MRI parameters

    Energy Technology Data Exchange (ETDEWEB)

    Denecke, Timm; Misch, Daniel; Steffen, Ingo G.; Plotkin, Michail; Stoever, Brigitte [Charite - Universitaetsmedizin Berlin, Klinik fuer Strahlenheilkunde, Campus Virchow-Klinikum, Berlin (Germany); Hundsdoerfer, Patrick; Henze, Guenter [Charite - Universitaetsmedizin Berlin, Klinik fuer Paediatrie m.S. Onkologie und Haematologie, Otto-Heubner-Zentrum, Campus Virchow-Klinikum, Berlin (Germany); Schoenberger, Stefan [Universitaetsklinikum der Heinrich-Heine-Universitaet Duesseldorf, Klinik fuer Kinder-Onkologie, -Haematologie und -Immunologie, Duesseldorf (Germany); Furth, Christian; Ruf, Juri [Otto-von-Guericke-Universitaet Magdeburg, Klinik fuer Radiologie und Nuklearmedizin, Universitaetsklinikum Magdeburg A.oe.R., Magdeburg (Germany); Hautzel, Hubertus [Universitaetsklinikum der Heinrich Heine Universitaet Duesseldorf, Nuklearmedizinische Klinik, Duesseldorf (Germany); Kluge, Regine [Universitaetsklinikum Leipzig A.oe.R., Klinik und Poliklinik fuer Nuklearmedizin, Leipzig (Germany); Bierbach, Uta [Universitaetsklinikum Leipzig A.oe.R., Abteilung fuer Kinder-Haematologie, -Onkologie und -Haemostaseologie, Leipzig (Germany); Otto, Sylke [Universitaetsklinikum Greifswald, Institut fuer Diagnostische Radiologie und Neuroradiologie, Greifswald (Germany); Beck, James F. [Universitaetsklinikum Greifswald, Abteilung fuer Paediatrische Haematologie und Onkologie, Greifswald (Germany); Franzius, Christiane [MR- und PET/CT-Zentrum, Bremen-Mitte (Germany); Universitaetsklinikum Muenster, Klinik und Poliklinik fuer Nuklearmedizin, Muenster (Germany); Amthauer, Holger [Charite - Universitaetsmedizin Berlin, Klinik fuer Strahlenheilkunde, Campus Virchow-Klinikum, Berlin (Germany); Otto-von-Guericke-Universitaet Magdeburg, Klinik fuer Radiologie und Nuklearmedizin, Universitaetsklinikum Magdeburg A.oe.R., Magdeburg (Germany)

    2010-10-15

    The objective of this study was to evaluate positron emission tomography (PET) using {sup 18}F-fluoro-2-deoxy-D-glucose (FDG) in comparison to volumetry and standardized magnetic resonance imaging (MRI) parameters for the assessment of histological response in paediatric bone sarcoma patients. FDG PET and local MRI were performed in 27 paediatric sarcoma patients [Ewing sarcoma family of tumours (EWS), n = 16; osteosarcoma (OS), n = 11] prior to and after neoadjuvant chemotherapy before local tumour resection. Several parameters for assessment of response of the primary tumour to therapy by FDG PET and MRI were evaluated and compared with histopathological regression of the resected tumour as defined by Salzer-Kuntschik. FDG PET significantly discriminated responders from non-responders using the standardized uptake value (SUV) reduction and the absolute post-therapeutic SUV (SUV2) in the entire patient population ({nabla}SUV, p = 0.005; SUV2, p = 0.011) as well as in the subgroup of OS patients ({nabla}SUV, p = 0.009; SUV2, p = 0.028), but not in the EWS subgroup. The volume reduction measured by MRI/CT did not significantly discriminate responders from non-responders either in the entire population (p = 0.170) or in both subgroups (EWS, p = 0.950; OS, p = 1.000). The other MRI parameters alone or in combination were unreliable and did not improve the results. Comparing diagnostic parameters of FDG PET and local MRI, metabolic imaging showed high superiority in the subgroup of OS patients, while similar results were observed in the population of EWS. FDG PET appears to be a useful tool for non-invasive response assessment in the group of OS patients and is superior to MRI. In EWS patients, however, neither FDG PET nor volumetry or standardized MRI criteria enabled a reliable response assessment to be made after neoadjuvant treatment. (orig.)

  14. A Global Assessment on Climate Research Engaging Indigenous Knowledge Systems and Recommendations for Quality Standards of Research Practice in Indigenous Communities

    Science.gov (United States)

    Davíd-Chavez, D. M.; Gavin, M. C.

    2017-12-01

    Indigenous communities worldwide have maintained their own knowledge systems for millennia informed through careful observation of dynamics of environmental changes. Withstanding centuries of challenges to their rights to maintain and practice these knowledge systems, Indigenous peoples continually speak to a need for quality standards for research in their communities. Although, international and Indigenous peoples' working groups emphasize Indigenous knowledge systems and the communities who hold them as critical resources for understanding and adapting to climate change, there has yet to be a comprehensive, evidence based analysis into how diverse knowledge systems are integrated in scientific studies. Do current research practices challenge or support Indigenous communities in their efforts to maintain and appropriately apply their knowledge systems? This study addresses this question using a systematic literature review and meta-analysis assessing levels of Indigenous community participation and decision-making in all stages of the research process (initiation, design, implementation, analysis, dissemination). Assessment is based on reported quality indicators such as: outputs that serve the community, ethical guidelines in practice (free, prior, and informed consent and intellectual property rights), and community access to findings. These indicators serve to identify patterns between levels of community participation and quality standards in practice. Meta-analysis indicates most climate studies practice an extractive model in which Indigenous knowledge systems are co-opted with minimal participation or decision-making authority from communities who hold them. Few studies report outputs that directly serve Indigenous communities, ethical guidelines in practice, or community access to findings. Studies reporting the most quality indicators were initiated in mutual agreement between Indigenous communities and outside researchers or by communities themselves

  15. Introduction of a new standardized assessment score of spine morphology in osteogenesis imperfecta

    Energy Technology Data Exchange (ETDEWEB)

    Koerber, F.; Schulze Uphoff, U.; Koerber, S.; Maintz, D. [Koeln Univ. (Germany). Dept. of Radiology; Schoenau, E.; Semler, O. [Koeln Univ. (Germany). Children' s Hospital

    2012-08-15

    Purpose: Osteogenesis imperfecta (OI) is a rare hereditary disease leading to multiple bone deformities and fractures. In the absence of causal therapy, a symptomatic approach is based on treatment with bisphosphonates and physiotherapy. The clinical and radiological manifestations vary. Therefore, standardization and quantification for an objective comparison, especially during therapy, are required. In this paper, radiological changes of the spine are quantified according to their clinical relevance to define a scoring system that transfers the morphological changes into a single value representing the severity of the disease. Materials and Methods: 268 lateral spine X-rays of 95 patients with OI (median age 5.6 years) were assessed. The findings were classified based on their clinical relevance. Results: The three criteria, vertebral compression, thoracolumbar kyphosis and deformity type, were quantified in a new grading system. Based on this, a 'severity classification' (1 to 5) was defined with implications for diagnostics and treatment. A mathematical formula that takes into account the three criteria and their correlations to clinical relevance, resulting in a 'severity score', was developed. Conclusion: 'Severity classification' and 'severity score' introduce a new concept for a standardized evaluation of spine X-rays in patients with OI. For both scientific and routine purposes, it provides the user with a simple and easy-to-handle tool for assessing and comparing different stages of severity prior to and during therapy with detailed accuracy. (orig.)

  16. MRI of the temporo-mandibular joint: which sequence is best suited to assess the cortical bone of the mandibular condyle? A cadaveric study using micro-CT as the standard of reference

    International Nuclear Information System (INIS)

    Karlo, Christoph A.; Patcas, Raphael; Signorelli, Luca; Mueller, Lukas; Kau, Thomas; Watzal, Helmut; Kellenberger, Christian J.; Ullrich, Oliver; Luder, Hans-Ulrich

    2012-01-01

    To determine the best suited sagittal MRI sequence out of a standard temporo-mandibular joint (TMJ) imaging protocol for the assessment of the cortical bone of the mandibular condyles of cadaveric specimens using micro-CT as the standard of reference. Sixteen TMJs in 8 human cadaveric heads (mean age, 81 years) were examined by MRI. Upon all sagittal sequences, two observers measured the cortical bone thickness (CBT) of the anterior, superior and posterior portions of the mandibular condyles (i.e. objective analysis), and assessed for the presence of cortical bone thinning, erosions or surface irregularities as well as subcortical bone cysts and anterior osteophytes (i.e. subjective analysis). Micro-CT of the condyles was performed to serve as the standard of reference for statistical analysis. Inter-observer agreements for objective (r = 0.83-0.99, P < 0.01) and subjective (κ = 0.67-0.88) analyses were very good. Mean CBT measurements were most accurate, and cortical bone thinning, erosions, surface irregularities and subcortical bone cysts were best depicted on the 3D fast spoiled gradient echo recalled sequence (3D FSPGR). The most reliable MRI sequence to assess the cortical bone of the mandibular condyles on sagittal imaging planes is the 3D FSPGR sequence. (orig.)

  17. MRI of the temporo-mandibular joint: which sequence is best suited to assess the cortical bone of the mandibular condyle? A cadaveric study using micro-CT as the standard of reference

    Energy Technology Data Exchange (ETDEWEB)

    Karlo, Christoph A. [University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); Patcas, Raphael; Signorelli, Luca; Mueller, Lukas [University of Zurich, Clinic for Orthodontics and Pediatric Dentistry, Center of Dental Medicine, Zurich (Switzerland); Kau, Thomas; Watzal, Helmut; Kellenberger, Christian J. [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); Ullrich, Oliver [University of Zurich, Institute of Anatomy, Faculty of Medicine, Zurich (Switzerland); Luder, Hans-Ulrich [University of Zurich, Section of Orofacial Structures and Development, Center of Dental Medicine, Zurich (Switzerland)

    2012-07-15

    To determine the best suited sagittal MRI sequence out of a standard temporo-mandibular joint (TMJ) imaging protocol for the assessment of the cortical bone of the mandibular condyles of cadaveric specimens using micro-CT as the standard of reference. Sixteen TMJs in 8 human cadaveric heads (mean age, 81 years) were examined by MRI. Upon all sagittal sequences, two observers measured the cortical bone thickness (CBT) of the anterior, superior and posterior portions of the mandibular condyles (i.e. objective analysis), and assessed for the presence of cortical bone thinning, erosions or surface irregularities as well as subcortical bone cysts and anterior osteophytes (i.e. subjective analysis). Micro-CT of the condyles was performed to serve as the standard of reference for statistical analysis. Inter-observer agreements for objective (r = 0.83-0.99, P < 0.01) and subjective ({kappa} = 0.67-0.88) analyses were very good. Mean CBT measurements were most accurate, and cortical bone thinning, erosions, surface irregularities and subcortical bone cysts were best depicted on the 3D fast spoiled gradient echo recalled sequence (3D FSPGR). The most reliable MRI sequence to assess the cortical bone of the mandibular condyles on sagittal imaging planes is the 3D FSPGR sequence. (orig.)

  18. Performance assessment of select covers and disposal cell compliance with EPA [Environmental Protection Agency] groundwater standards

    International Nuclear Information System (INIS)

    1989-06-01

    This document describes the technical approach to the assessment of the performance of a full component topslope cover, three sideslope covers, and hence the way in which a Uranium Mill Tailings Remedial Action (UMTRA) Project disposal cell complies with the US Environmental Protection Agency (EPA) groundwater protection standards. 4 refs

  19. States' Participation Guidelines for Alternate Assessments Based on Modified Academic Achievement Standards (AA-MAS) in 2008. Synthesis Report 71

    Science.gov (United States)

    Lazarus, Sheryl S.; Rogers, Christopher; Cormier, Damien; Thurlow, Martha L.

    2008-01-01

    Federal regulations (U.S. Department of Education, 2007a) provide states with the flexibility to offer an alternate assessment based on modified academic achievement standards (AA-MAS). This assessment option is for a small group of students with disabilities who can make significant progress, but may not reach grade-level achievement within the…

  20. Prospective study on cost-effectiveness of home-based motor assessment in Parkinson's disease.

    Science.gov (United States)

    Cubo, E; Mariscal, N; Solano, B; Becerra, V; Armesto, D; Calvo, S; Arribas, J; Seco, J; Martinez, A; Zorrilla, L; Heldman, D

    2017-02-01

    Introduction Treatment adjustments in Parkinson's disease (PD) are in part dependent on motor assessments. The aim of this study was to evaluate the cost-effectiveness of home-based motor monitoring plus standard in-office visits versus in-office visits alone in patients with advanced PD. Methods The procedures consisted of a prospective, one-year follow-up, randomized, case-control study. A total of 40 patients with advanced PD were randomized into two groups: 20 patients underwent home-based motor monitoring by using wireless motion sensor technology, while the other 20 patients had in-office visits. Motor and non-motor symptom severities, quality of life, neuropsychiatric symptoms, and comorbidities were assessed every four months. Direct costs were assessed using a standardized questionnaire. Cost-effectiveness was assessed using the incremental cost-effectiveness ratio (ICER). Results Both groups of PD patients were largely comparable in their clinical and demographic variables at baseline; however, there were more participants using levodopa-carbidopa intestinal gel in the home-based motor monitoring group. There was a trend for lower Unified Parkinson's Disease Rating Scale functional status (UPDRS II) scores in the patients monitored at home compared to the standard clinical follow-up ( p = 0.06). However, UPDRS parts I, III, IV and quality-adjusted life-years scores were similar between both groups. Home-based motor monitoring was cost-effective in terms of improvement of functional status, motor severity, and motor complications (UPDRS II, III; IV subscales), with an ICER/UPDRS ranging from €126.72 to €701.31, respectively. Discussion Home-based motor monitoring is a tool which collects cost-effective clinical information and helps augment health care for patients with advanced PD.

  1. Modern standardization case studies at the crossroads of technology, economics, and politics

    CERN Document Server

    Schneiderman, R

    2015-01-01

    Modern Standardization -- Case Studies at the Crossroads of Technology, Economics, and Politics covers the development of new technical standards, how these standards are typically triggered, and how they are submitted to standards development organizations (SDOs) for review and evaluation. It fills the gap in the shortage of reference material in the development of real-world standards. The increasing pace of innovation in technology has accelerated the competitive nature of standardization, particularly in emerging markets. Modern Standardization addresses these and other issues through a series of case studies in a format designed for academics and their engineering, business, and law school students.

  2. Study on the standard establishment for the integrity assessment of nuclear fuel cladding Materials

    Energy Technology Data Exchange (ETDEWEB)

    Kang, S. S.; Kim, S. H.; Jung, Y. K.; Yang, C. Y.; Kim, I. G.; Choi, Y. H.; Kim, H. J.; Kim, M. W.; Rho, B. H. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2007-02-15

    Fuel cladding material plays important role as a primary structure under the high temperature, high pressure and neutron environment of nuclear power plant. According to this environment, cladding material can be experienced several type aging phenomena including the neutron irradiation embrittlement. On the other hand, although the early nuclear power plant was designed to fitting into the 40MWd/KgU burn-up, the currently power plant intends to go to the high burn-up range. In this case, the safety criteria which was established at low burn-up needs to conform the applicability at the high burn-up. In this study, the safety criteria of fuel cladding material was reviewed to assess the cladding material integrity, and the material characteristics of cladding were reviewed. The current LOCA criterial was also reviewed, and the basic study for re-establishment of LOCA criteria was performed. The time concept safety criteria was also discussed to prevent the breakaway oxidation. Through the this study, safety issues will be produced and be helpful for integrity insurance of nuclear fuel cladding material. This report is 2nd term report.

  3. A Study of State Social Studies Standards for American Indian Education

    Science.gov (United States)

    Warner, Connor K.

    2015-01-01

    In this study the author surveys social studies standards from 14 U.S. states seeking to answer: (a) what social studies knowledge about American Indians is deemed essential by those states mandating the development of American Indian Education curricula for all public K-12 students? and (b) at what grade levels is this social studies content…

  4. A study on the effects of the CAFE standard on consumers

    International Nuclear Information System (INIS)

    Jun, Seung-Pyo; Yoo, Hyoung Sun; Kim, Ji-Hui

    2016-01-01

    In this paper, we analyzed how the CAFE standard has affected improvements in the fuel economy of vehicles, as examined in other preceding studies, but in addition, we also analyzed how these standards have affected the level of consumer interest in fuel economy. Our goal was to determine what effects the government intervention has had on consumers, and whether such intervention ought to be continued. The results showed that not only has the CAFE standard had a direct and significant impact on improving fuel economy and increasing the market share of fuel-efficient vehicles, it has also boosted the development of technologies for enhancing fuel economy and raised consumer interest in fuel economy, thus indirectly contributing to overcoming market failure. The significance of this study is that we used publically available observed data and analyzed the recent impact of the CAFE standard specifically with a focus on the behavior and strategies exhibited by consumers and automakers. Another significance of this study is that it extends our purview to examine the effects that the CAFE standard has had in other countries (Korea). - Highlights: •CAFE standards have raised consumer interest in fuel economy such as MPG. •CAFE standards had a significant impact on increasing fuel-efficient vehicles •Sales of HEVs are more significantly affected by CAFE standards than by WTI. •CAFE standards had a significant impact on a foreign vehicle market. •Analysis suggests the standards will continue to be necessary for market growth.

  5. False Labor at Term in Singleton Pregnancies: Discharge After a Standardized Assessment and Perinatal Outcomes.

    Science.gov (United States)

    Nelson, David B; McIntire, Donald D; Leveno, Kenneth J

    2017-07-01

    To evaluate perinatal outcomes in women sent home with a diagnosis of false labor at term and assess the time interval to return for delivery. This was a prospective observational cohort study of women at 37 0/7 to 41 6/7 weeks of gestation without pre-existing medical complications who presented to our hospital-based triage unit with symptoms of labor and underwent a standardized evaluation. Women diagnosed as having false labor with a live singleton fetus in cephalic presentation without a prior cesarean delivery and sent home were compared with a group of similar women diagnosed to be in spontaneous labor. Women with hypertension, diabetes, and known fetal malformations were excluded. Using a perinatal composite outcome of respiratory insufficiency, intraventricular hemorrhage, culture-proven sepsis, Apgar score 3 or less at 5 minutes, phototherapy, and perinatal death, we tested the noninferiority of being sent home compared with being admitted for labor. The relationship of cervical dilatation to the time interval from discharge home to delivery was also analyzed. Between October 2012 and March 2016, a total of 3,949 women met inclusion criteria and were diagnosed with false labor, discharged, and returned to deliver, whereas 2,592 similar women were admitted in early labor. The mean interval from discharge to return was 4.9 days. Cesarean delivery rates were not different between the study groups-11% for both (P=.69), and the perinatal composite outcome rates were not significantly different between those sent home and those admitted-3.2% compared with 3.1% (P=.79). Women with more advanced cervical dilatation at discharge returned and delivered significantly earlier than those with less dilatation regardless of parity. Discharge with false labor at term after a standardized assessment in a triage unit was not associated with increased rates of adverse perinatal composite outcomes or cesarean delivery. The time interval to return for delivery was

  6. Standardization of the Food Composition Database Used in the Latin American Nutrition and Health Study (ELANS).

    Science.gov (United States)

    Kovalskys, Irina; Fisberg, Mauro; Gómez, Georgina; Rigotti, Attilio; Cortés, Lilia Yadira; Yépez, Martha Cecilia; Pareja, Rossina G; Herrera-Cuenca, Marianella; Zimberg, Ioná Z; Tucker, Katherine L; Koletzko, Berthold; Pratt, Michael

    2015-09-16

    Between-country comparisons of estimated dietary intake are particularly prone to error when different food composition tables are used. The objective of this study was to describe our procedures and rationale for the selection and adaptation of available food composition to a single database to enable cross-country nutritional intake comparisons. Latin American Study of Nutrition and Health (ELANS) is a multicenter cross-sectional study of representative samples from eight Latin American countries. A standard study protocol was designed to investigate dietary intake of 9000 participants enrolled. Two 24-h recalls using the Multiple Pass Method were applied among the individuals of all countries. Data from 24-h dietary recalls were entered into the Nutrition Data System for Research (NDS-R) program after a harmonization process between countries to include local foods and appropriately adapt the NDS-R database. A food matching standardized procedure involving nutritional equivalency of local food reported by the study participants with foods available in the NDS-R database was strictly conducted by each country. Standardization of food and nutrient assessments has the potential to minimize systematic and random errors in nutrient intake estimations in the ELANS project. This study is expected to result in a unique dataset for Latin America, enabling cross-country comparisons of energy, macro- and micro-nutrient intake within this region.

  7. Standardization of the Food Composition Database Used in the Latin American Nutrition and Health Study (ELANS)

    Science.gov (United States)

    Kovalskys, Irina; Fisberg, Mauro; Gómez, Georgina; Rigotti, Attilio; Cortés, Lilia Yadira; Yépez, Martha Cecilia; Pareja, Rossina G.; Herrera-Cuenca, Marianella; Zimberg, Ioná Z.; Tucker, Katherine L.; Koletzko, Berthold; Pratt, Michael

    2015-01-01

    Between-country comparisons of estimated dietary intake are particularly prone to error when different food composition tables are used. The objective of this study was to describe our procedures and rationale for the selection and adaptation of available food composition to a single database to enable cross-country nutritional intake comparisons. Latin American Study of Nutrition and Health (ELANS) is a multicenter cross-sectional study of representative samples from eight Latin American countries. A standard study protocol was designed to investigate dietary intake of 9000 participants enrolled. Two 24-h recalls using the Multiple Pass Method were applied among the individuals of all countries. Data from 24-h dietary recalls were entered into the Nutrition Data System for Research (NDS-R) program after a harmonization process between countries to include local foods and appropriately adapt the NDS-R database. A food matching standardized procedure involving nutritional equivalency of local food reported by the study participants with foods available in the NDS-R database was strictly conducted by each country. Standardization of food and nutrient assessments has the potential to minimize systematic and random errors in nutrient intake estimations in the ELANS project. This study is expected to result in a unique dataset for Latin America, enabling cross-country comparisons of energy, macro- and micro-nutrient intake within this region. PMID:26389952

  8. Standardization of the Food Composition Database Used in the Latin American Nutrition and Health Study (ELANS

    Directory of Open Access Journals (Sweden)

    Irina Kovalskys

    2015-09-01

    Full Text Available Between-country comparisons of estimated dietary intake are particularly prone to error when different food composition tables are used. The objective of this study was to describe our procedures and rationale for the selection and adaptation of available food composition to a single database to enable cross-country nutritional intake comparisons. Latin American Study of Nutrition and Health (ELANS is a multicenter cross-sectional study of representative samples from eight Latin American countries. A standard study protocol was designed to investigate dietary intake of 9000 participants enrolled. Two 24-h recalls using the Multiple Pass Method were applied among the individuals of all countries. Data from 24-h dietary recalls were entered into the Nutrition Data System for Research (NDS-R program after a harmonization process between countries to include local foods and appropriately adapt the NDS-R database. A food matching standardized procedure involving nutritional equivalency of local food reported by the study participants with foods available in the NDS-R database was strictly conducted by each country. Standardization of food and nutrient assessments has the potential to minimize systematic and random errors in nutrient intake estimations in the ELANS project. This study is expected to result in a unique dataset for Latin America, enabling cross-country comparisons of energy, macro- and micro-nutrient intake within this region.

  9. State-of-the art comparability of corrected emission spectra. 2. Field laboratory assessment of calibration performance using spectral fluorescence standards.

    Science.gov (United States)

    Resch-Genger, Ute; Bremser, Wolfram; Pfeifer, Dietmar; Spieles, Monika; Hoffmann, Angelika; DeRose, Paul C; Zwinkels, Joanne C; Gauthier, François; Ebert, Bernd; Taubert, R Dieter; Voigt, Jan; Hollandt, Jörg; Macdonald, Rainer

    2012-05-01

    In the second part of this two-part series on the state-of-the-art comparability of corrected emission spectra, we have extended this assessment to the broader community of fluorescence spectroscopists by involving 12 field laboratories that were randomly selected on the basis of their fluorescence measuring equipment. These laboratories performed a reference material (RM)-based fluorometer calibration with commercially available spectral fluorescence standards following a standard operating procedure that involved routine measurement conditions and the data evaluation software LINKCORR developed and provided by the Federal Institute for Materials Research and Testing (BAM). This instrument-specific emission correction curve was subsequently used for the determination of the corrected emission spectra of three test dyes, X, QS, and Y, revealing an average accuracy of 6.8% for the corrected emission spectra. This compares well with the relative standard uncertainties of 4.2% for physical standard-based spectral corrections demonstrated in the first part of this study (previous paper in this issue) involving an international group of four expert laboratories. The excellent comparability of the measurements of the field laboratories also demonstrates the effectiveness of RM-based correction procedures.

  10. Standardization and integration of ecological and human risk assessments at Department of Energy national laboratories

    International Nuclear Information System (INIS)

    Breckenridge, R.P.; Berry, D.

    1995-01-01

    In 1990, the directors of twelve national laboratories operated by the US Department of Energy (DOE) chartered a steering group to address DOE's concerns about the effectiveness of any regulations driving the cost of environmental restoration and waste management. The goal of this presentation is to inform and to seek collaboration on the challenge of standardizing ecological and human health risk assessment approaches and development of an approach to address the differences between environmental remediation and restoration activities at DOE's waste management sites across the country. Recent changes in risk related regulations and budget cuts have prompted significant changes in DOE's approach to conducting and standardizing risk-based approaches for waste management. The steering group was established in 1990 to organize a broad, long-term educational outreach and research program focused on better science and public understanding of the risks associated with hazardous agents (chemical, biological, radiological, and physical) in the environment and the workplace. This presentation discusses the group's goal to (1) act as one resource for providing the technical basis for health and environmental standards; (2) catalyze a national effort to improve public understanding of risk and the importance of cost benefit analysis in evaluating mitigation of risk; (3) catalyze improvements in understanding of health and environmental effects of hazardous agents; and (4) analyze with regulatory agencies, industry, and the public the potential for evolution of risk-based consensus standard into federal and state environmental and occupational/public health regulations. Major accomplishments will be presented along with the group's agenda for standardizing risk, environmental, and occupational/public health standards

  11. The effectiveness of Microsoft Project in assessing extension of time under PAM 2006 standard form of contract

    Science.gov (United States)

    Suhaida, S. K.; Wong, Z. D.

    2017-11-01

    Time is equal to money; and it is applies in the construction industry where time is very important. Most of the standard form of contracts provide contractual clauses to ascertain time and money related to the scenarios while Extension of Time (EOT) is one of them. Under circumstance and delays, contractor is allow to apply EOT in order to complete the works on a later completion date without Liquidated Damages (LD) imposed to the claimant. However, both claimants and assessors encountered problems in assessing the EOT. The aim of this research is to recommend the usage of Microsoft Project as a tool in assessing EOT associated with the standard form of contract, PAM 2006. A quantitative method is applied towards the respondents that consisted of architects and quantity surveyors (QS) in order to collect data on challenges in assessing EOT claims and the effectiveness of Microsoft Project as a tool. The finding of this research highlighted that Microsoft Project can serve as a basis to perform EOT tasks as this software can be used as a data bank to store handy information which crucial for preparing and evaluating EOT.

  12. How Clean Are Hotel Rooms? Part II: Examining the Concept of Cleanliness Standards.

    Science.gov (United States)

    Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay

    2015-01-01

    Hotel room cleanliness is based on observation and not on microbial assessment even though recent reports suggest that infections may be acquired while staying in hotel rooms. Exploratory research in the first part of the authors' study was conducted to determine if contamination of hotel rooms occurs and whether visual assessments are accurate indicators of hotel room cleanliness. Data suggested the presence of microbial contamination that was not reflective of visual assessments. Unfortunately, no standards exist for interpreting microbiological data and other indicators of cleanliness in hotel rooms. The purpose of the second half of the authors' study was to examine cleanliness standards in other industries to see if they might suggest standards in hotels. Results of the authors' study indicate that standards from other related industries do not provide analogous criteria, but do provide suggestions for further research.

  13. Obsolete Laws: Economic and Moral Aspects, Case Study-Composting Standards.

    Science.gov (United States)

    Vochozka, Marek; Maroušková, Anna; Šuleř, Petr

    2017-12-01

    From the early days of philosophy, ethics and justice, there is wide consensus that the constancy of the laws establishes the legal system. On the other hand, the rate at which we accumulate knowledge is gaining speed like never before. Due to the recently increased attention of academics to climate change and other environmental issues, a lot of new knowledge has been obtained about carbon management, its role in nature and mechanisms regarding the formation and degradation of organic matter. A multidisciplinary techno-economic assessment of current composting standards and laws that took into account the current state of knowledge about carbon management was carried out as a case study. Economic and environmental damage caused by outdated laws was revealed. In addition, it was found that the introduction of the best composts into the market is permitted, causing additional negative environmental as well as economic impacts.

  14. Current standards of neuropsychological assessment in epilepsy surgery centers across Europe.

    Science.gov (United States)

    Vogt, Viola Lara; Äikiä, Marja; Del Barrio, Antonio; Boon, Paul; Borbély, Csaba; Bran, Ema; Braun, Kees; Carette, Evelien; Clark, Maria; Cross, Judith Helen; Dimova, Petia; Fabo, Daniel; Foroglou, Nikolaos; Francione, Stefano; Gersamia, Anna; Gil-Nagel, Antonio; Guekht, Alla; Harrison, Sue; Hecimovic, Hrvoje; Heminghyt, Einar; Hirsch, Edouard; Javurkova, Alena; Kälviäinen, Reetta; Kavan, Nicole; Kelemen, Anna; Kimiskidis, Vasilios K; Kirschner, Margarita; Kleitz, Catherine; Kobulashvili, Teia; Kosmidis, Mary H; Kurtish, Selin Yagci; Lesourd, Mathieu; Ljunggren, Sofia; Lossius, Morten Ingvar; Malmgren, Kristina; Mameniskiené, Ruta; Martin-Sanfilippo, Patricia; Marusic, Petr; Miatton, Marijke; Özkara, Çiğdem; Pelle, Federica; Rubboli, Guido; Rudebeck, Sarah; Ryvlin, Philippe; van Schooneveld, Monique; Schmid, Elisabeth; Schmidt, Pia-Magdalena; Seeck, Margitta; Steinhoff, Bernhard J; Shavel-Jessop, Sara; Tarta-Arsene, Oana; Trinka, Eugen; Viggedal, Gerd; Wendling, Anne-Sophie; Witt, Juri-Alexander; Helmstaedter, Christoph

    2017-03-01

    We explored the current practice with respect to the neuropsychological assessment of surgical epilepsy patients in European epilepsy centers, with the aim of harmonizing and establishing common standards. Twenty-six epilepsy centers and members of "E-PILEPSY" (a European pilot network of reference centers in refractory epilepsy and epilepsy surgery), were asked to report the status of neuropsychological assessment in adults and children via two different surveys. There was a consensus among these centers regarding the role of neuropsychology in the presurgical workup. Strong agreement was found on indications (localization, epileptic dysfunctions, adverse drugs effects, and postoperative monitoring) and the domains to be evaluated (memory, attention, executive functions, language, visuospatial skills, intelligence, depression, anxiety, and quality of life). Although 186 different tests are in use throughout these European centers, a core group of tests reflecting a moderate level of agreement could be discerned. Variability exists with regard to indications, protocols, and paradigms for the assessment of hemispheric language dominance. For the tests in use, little published evidence of clinical validity in epilepsy was provided. Participants in the survey reported a need for improvement concerning the validity of the tests, tools for the assessment of everyday functioning and accelerated forgetting, national norms, and test co-normalization. Based on the present survey, we documented a consensus regarding the indications and principles of neuropsychological testing. Despite the variety of tests in use, the survey indicated that there may be a core set of tests chosen based on experience, as well as on published evidence. By combining these findings with the results of an ongoing systematic literature review, we aim for a battery that can be recommended for the use across epilepsy surgical centers in Europe. Wiley Periodicals, Inc. © 2017 International League

  15. The Universal Thermal Climate Index UTCI compared to ergonomics standards for assessing the thermal environment.

    Science.gov (United States)

    Bröde, Peter; Błazejczyk, Krzysztof; Fiala, Dusan; Havenith, George; Holmér, Ingvar; Jendritzky, Gerd; Kuklane, Kalev; Kampmann, Bernhard

    2013-01-01

    The growing need for valid assessment procedures of the outdoor thermal environment in the fields of public weather services, public health systems, urban planning, tourism & recreation and climate impact research raised the idea to develop the Universal Thermal Climate Index UTCI based on the most recent scientific progress both in thermo-physiology and in heat exchange theory. Following extensive validation of accessible models of human thermoregulation, the advanced multi-node 'Fiala' model was selected to form the basis of UTCI. This model was coupled with an adaptive clothing model which considers clothing habits by the general urban population and behavioral changes in clothing insulation related to actual environmental temperature. UTCI was developed conceptually as an equivalent temperature. Thus, for any combination of air temperature, wind, radiation, and humidity, UTCI is defined as the air temperature in the reference condition which would elicit the same dynamic response of the physiological model. This review analyses the sensitivity of UTCI to humidity and radiation in the heat and to wind in the cold and compares the results with observational studies and internationally standardized assessment procedures. The capabilities, restrictions and potential future extensions of UTCI are discussed.

  16. STANDARDIZATION OR ADAPTATION IN COSMETICS WEBSITES MARKETING ? AN EMPIRICAL STUDY.

    Directory of Open Access Journals (Sweden)

    Anca Constantinescu-Dobra

    2011-06-01

    Full Text Available The websites marketing is becoming an important tool both for multinationals and SMEs, in their effort to internationalizing their business.This study focuses on the international opportunities that are present within the European markets. The paper aims at identifying the degree of websites marketing standardization vs. adaptation, as a marketing tool for cosmetic products. Moreover, the study examines in a comparative manner the standardization strategy of multinationals and small and medium enterprises (SMEs, leaders in European markets, for different cosmetic cathegories.The evaluation of online advertising standardization is based on the modified Model for Testing Advertising Standardization, developed by Whitelock and Chung. The web sites degree of localizations areanalyzed based upon 98 criteria, as resulted from an adapted methodology of ProfNet Institut fur Internet Marketing, Munster (Germany. The sample includes the 101 leaders from European markets.The research outcomes reflect a standardized websites marketing policy for SMEs and localized for multinationals. Also, for perfumes, dental care products and toiletry, European cosmetic leaders implementstandardized websites marketing policies and balanced for the other cosmetics categories. The hypothesis concerning a strong correlation between standardization and handling dimension was supported.

  17. Standard setting: comparison of two methods.

    Science.gov (United States)

    George, Sanju; Haque, M Sayeed; Oyebode, Femi

    2006-09-14

    The outcome of assessments is determined by the standard-setting method used. There is a wide range of standard-setting methods and the two used most extensively in undergraduate medical education in the UK are the norm-reference and the criterion-reference methods. The aims of the study were to compare these two standard-setting methods for a multiple-choice question examination and to estimate the test-retest and inter-rater reliability of the modified Angoff method. The norm-reference method of standard-setting (mean minus 1 SD) was applied to the 'raw' scores of 78 4th-year medical students on a multiple-choice examination (MCQ). Two panels of raters also set the standard using the modified Angoff method for the same multiple-choice question paper on two occasions (6 months apart). We compared the pass/fail rates derived from the norm reference and the Angoff methods and also assessed the test-retest and inter-rater reliability of the modified Angoff method. The pass rate with the norm-reference method was 85% (66/78) and that by the Angoff method was 100% (78 out of 78). The percentage agreement between Angoff method and norm-reference was 78% (95% CI 69% - 87%). The modified Angoff method had an inter-rater reliability of 0.81-0.82 and a test-retest reliability of 0.59-0.74. There were significant differences in the outcomes of these two standard-setting methods, as shown by the difference in the proportion of candidates that passed and failed the assessment. The modified Angoff method was found to have good inter-rater reliability and moderate test-retest reliability.

  18. 75 FR 80866 - Credit Rating Standardization Study

    Science.gov (United States)

    2010-12-23

    ... commenters believe that market stress conditions can be defined in a consistent manner across different... Securities and Exchange Commission is requesting public comment to help inform its study pursuant to Section... ratings using identical terms; standardizing the market stress conditions under which ratings are...

  19. Assessing the cleanliness of surfaces: Innovative molecular approaches vs. standard spore assays

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, M.; Duc, M.T. La; Probst, A.; Vaishampayan, P.; Stam, C.; Benardini, J.N.; Piceno, Y.M.; Andersen, G.L.; Venkateswaran, K.

    2011-04-01

    A bacterial spore assay and a molecular DNA microarray method were compared for their ability to assess relative cleanliness in the context of bacterial abundance and diversity on spacecraft surfaces. Colony counts derived from the NASA standard spore assay were extremely low for spacecraft surfaces. However, the PhyloChip generation 3 (G3) DNA microarray resolved the genetic signatures of a highly diverse suite of microorganisms in the very same sample set. Samples completely devoid of cultivable spores were shown to harbor the DNA of more than 100 distinct microbial phylotypes. Furthermore, samples with higher numbers of cultivable spores did not necessarily give rise to a greater microbial diversity upon analysis with the DNA microarray. The findings of this study clearly demonstrated that there is not a statistically significant correlation between the cultivable spore counts obtained from a sample and the degree of bacterial diversity present. Based on these results, it can be stated that validated state-of-the-art molecular techniques, such as DNA microarrays, can be utilized in parallel with classical culture-based methods to further describe the cleanliness of spacecraft surfaces.

  20. Standards and quality

    CERN Document Server

    El-Tawil, Anwar

    2015-01-01

    The book brings together a number of subjects of prime importance for any practicing engineer and, students of engineering. The book explains the concepts and functions of voluntary standards, mandatory technical regulations, conformity assessment (testing and measurement of products), certification, quality and quality management systems as well as other management systems such as environmental, social responsibility and food safety management systems.The book also gives a comprehensive description of the role of metrology systems that underpin conformity assessment. A description is given of typical national systems of standards, quality and metrology and how they relate directly or through regional structures to international systems. The book also covers the relation between standards and trade and explains the context and stipulations of the Technical Barriers to Trade Agreement of the World Trade Organization (WTO).

  1. Quantitative Rapid Assessment of Leukoaraiosis in CT : Comparison to Gold Standard MRI.

    Science.gov (United States)

    Hanning, Uta; Sporns, Peter Bernhard; Schmidt, Rene; Niederstadt, Thomas; Minnerup, Jens; Bier, Georg; Knecht, Stefan; Kemmling, André

    2017-10-20

    The severity of white matter lesions (WML) is a risk factor of hemorrhage and predictor of clinical outcome after ischemic stroke; however, in contrast to magnetic resonance imaging (MRI) reliable quantification for this surrogate marker is limited for computed tomography (CT), the leading stroke imaging technique. We aimed to present and evaluate a CT-based automated rater-independent method for quantification of microangiopathic white matter changes. Patients with suspected minor stroke (National Institutes of Health Stroke scale, NIHSS < 4) were screened for the analysis of non-contrast computerized tomography (NCCT) at admission and compared to follow-up MRI. The MRI-based WML volume and visual Fazekas scores were assessed as the gold standard reference. We employed a recently published probabilistic brain segmentation algorithm for CT images to determine the tissue-specific density of WM space. All voxel-wise densities were quantified in WM space and weighted according to partial probabilistic WM content. The resulting mean weighted density of WM space in NCCT, the surrogate of WML, was correlated with reference to MRI-based WML parameters. The process of CT-based tissue-specific segmentation was reliable in 79 cases with varying severity of microangiopathy. Voxel-wise weighted density within WM spaces showed a noticeable correlation (r = -0.65) with MRI-based WML volume. Particularly in patients with moderate or severe lesion load according to the visual Fazekas score the algorithm provided reliable prediction of MRI-based WML volume. Automated observer-independent quantification of voxel-wise WM density in CT significantly correlates with microangiopathic WM disease in gold standard MRI. This rapid surrogate of white matter lesion load in CT may support objective WML assessment and therapeutic decision-making during acute stroke triage.

  2. Standardizing metadata and taxonomic identification in metabarcoding studies

    NARCIS (Netherlands)

    Tedersoo, Leho; Ramirez, Kelly; Nilsson, R; Kaljuvee, Aivi; Koljalg, Urmas; Abarenkov, Kessy

    2015-01-01

    High-throughput sequencing-based metabarcoding studies produce vast amounts of ecological data, but a lack of consensus on standardization of metadata and how to refer to the species recovered severely hampers reanalysis and comparisons among studies. Here we propose an automated workflow covering

  3. Essential patents in industry standards : the case of UMTS

    NARCIS (Netherlands)

    Bekkers, R.N.A.; Bongard, R.; Nuvolari, A.

    2009-01-01

    We study the determinants of essential patents in industry standards. In particular, we assess the role of two main factors: the significance of the technological solution contained in the patent and the involvement of the applicant of the patent in the standardization process. To this end, we

  4. Constructing Assessment Model of Primary and Secondary Educational Quality with Talent Quality as the Core Standard

    Science.gov (United States)

    Chen, Benyou

    2014-01-01

    Quality is the core of education and it is important to standardization construction of primary and secondary education in urban (U) and rural (R) areas. The ultimate goal of the integration of urban and rural education is to pursuit quality urban and rural education. Based on analysing the related policy basis and the existing assessment models…

  5. Experimental study of hybrid-knife endoscopic submucosal dissection (ESD) versus standard ESD in a Western country.

    Science.gov (United States)

    De-la-Peña, Joaquín; Calderón, Ángel; Esteban, José Miguel; López-Rosés, Leopoldo; Martínez-Ares, David; Nogales, Óscar; Orive-Calzada, Aitor; Rodríguez, Sarbelio; Sánchez-Hernández, Eloy; Vila, Juan; Fernández-Esparrach, Gloria

    2014-02-01

    Endoscopic submucosal dissection (ESD) is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise. The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with high pressure water jet and to compare with standard ESD. We performed a prospective non survival animal study comparing hybrid-knife and standard gastric ESD. Variables recorded were: Number of en-bloc ESD, number of ESD with all marks included (R0), size of specimens, time and speed of dissection and adverse events. Ten endoscopists performed a total of 50 gastric ESD (30 hybrid-knife and 20 standard). Forty-six (92 %) ESD were en-bloc and 25 (50 %) R0 (hybrid-knife: n = 13, 44 %; standard: n = 16, 80 %; p = 0.04). Hybrid-knife ESD was faster than standard (time: 44.6 +/- 21.4 minutes vs. 68.7 +/- 33.5 minutes; p = 0.009 and velocity: 20.8 +/- 9.2 mm(2)/min vs. 14.3 +/- 9.3 mm(2)/min (p = 0.079). Adverse events were not different. There was no change in speed with any of two techniques (hybrid-knife: From 20.33 +/- 15.68 to 28.18 +/- 20.07 mm(2)/min; p = 0.615 and standard: From 6.4 +/- 0.3 to 19.48 +/- 19.21 mm(2)/min; p = 0.607). The learning curve showed a significant improvement in R0 rate in the hybrid-knife group (from 30 % to 100 %). despite the initial performance of hybrid-knife ESD is worse than standard ESD, the learning curve with hybrid knife ESD is short and is associated with a rapid improvement. The introduction of new tools to facilitate ESD should be implemented with caution in order to avoid a negative impact on the results.

  6. Assessment of Prospective Memory – a Validity Study of Memory for Intentions Screening Test

    NARCIS (Netherlands)

    Bezdicek, O.; Raskin, S.A.; Altgassen, A.M.; Ruzicka, E.

    2014-01-01

    Aim: The goal of the present study was to validate the Czech version of the Memory for Intentions (Screening) Test (MIST, 2010). We included standardized testing material, translation of administration and scoring, and assessment of normative data for the MIST in the Czech population. Introduction:

  7. Social Moderation, Assessment and Assuring Standards for Accounting Graduates

    Science.gov (United States)

    Watty, Kim; Freeman, Mark; Howieson, Bryan; Hancock, Phil; O'Connell, Brendan; de Lange, Paul; Abraham, Anne

    2014-01-01

    Evidencing student achievement of standards is a growing imperative worldwide. Key stakeholders (including current and prospective students, government, regulators and employers) want confidence that threshold learning standards in an accounting degree have been assured. Australia's new higher education regulatory environment requires that student…

  8. National and International Standardization (International Organization for Standardization and European Committee for Standardization Relevant for Sustainability in Construction

    Directory of Open Access Journals (Sweden)

    Renata Morbiducci

    2010-12-01

    Full Text Available Sustainability in construction has a short history in terms of principles, standardizations and applications. From the Brundtland Report “Our Common Future”, a new vision of the resource deficits, climate impacts and the social responsibility gave growth to the idea of sustainability also in design and construction. Consequently, in around 2000, the international and national organizations for standardization started to develop standards for the application of sustainable principles. This paper gives an overview of existing and planned standards, and examples on how to use them as a framework for the development of methods and tools for assessment.

  9. International collaborative study for the calibration of proposed International Standards for thromboplastin, rabbit, plain, and for thromboplastin, recombinant, human, plain.

    Science.gov (United States)

    van den Besselaar, A M H P; Chantarangkul, V; Angeloni, F; Binder, N B; Byrne, M; Dauer, R; Gudmundsdottir, B R; Jespersen, J; Kitchen, S; Legnani, C; Lindahl, T L; Manning, R A; Martinuzzo, M; Panes, O; Pengo, V; Riddell, A; Subramanian, S; Szederjesi, A; Tantanate, C; Herbel, P; Tripodi, A

    2018-01-01

    Essentials Two candidate International Standards for thromboplastin (coded RBT/16 and rTF/16) are proposed. International Sensitivity Index (ISI) of proposed standards was assessed in a 20-centre study. The mean ISI for RBT/16 was 1.21 with a between-centre coefficient of variation of 4.6%. The mean ISI for rTF/16 was 1.11 with a between-centre coefficient of variation of 5.7%. Background The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current Fourth International Standards are running low. Candidate replacement materials have been prepared. This article describes the calibration of the proposed Fifth International Standards for thromboplastin, rabbit, plain (coded RBT/16) and for thromboplastin, recombinant, human, plain (coded rTF/16). Methods An international collaborative study was carried out for the assignment of International Sensitivity Indexes (ISIs) to the candidate materials, according to the World Health Organization (WHO) guidelines for thromboplastins and plasma used to control oral anticoagulant therapy with vitamin K antagonists. Results Results were obtained from 20 laboratories. In several cases, deviations from the ISI calibration model were observed, but the average INR deviation attributabled to the model was not greater than 10%. Only valid ISI assessments were used to calculate the mean ISI for each candidate. The mean ISI for RBT/16 was 1.21 (between-laboratory coefficient of variation [CV]: 4.6%), and the mean ISI for rTF/16 was 1.11 (between-laboratory CV: 5.7%). Conclusions The between-laboratory variation of the ISI for candidate material RBT/16 was similar to that of the Fourth International Standard (RBT/05), and the between-laboratory variation of the ISI for candidate material rTF/16 was slightly higher than that of the Fourth International Standard (rTF/09). The candidate materials

  10. Assessment of severe malaria in a multicenter, phase III, RTS, S/AS01 malaria candidate vaccine trial: case definition, standardization of data collection and patient care.

    Science.gov (United States)

    Vekemans, Johan; Marsh, Kevin; Greenwood, Brian; Leach, Amanda; Kabore, William; Soulanoudjingar, Solange; Asante, Kwaku Poku; Ansong, Daniel; Evans, Jennifer; Sacarlal, Jahit; Bejon, Philip; Kamthunzi, Portia; Salim, Nahya; Njuguna, Patricia; Hamel, Mary J; Otieno, Walter; Gesase, Samwel; Schellenberg, David

    2011-08-04

    An effective malaria vaccine, deployed in conjunction with other malaria interventions, is likely to substantially reduce the malaria burden. Efficacy against severe malaria will be a key driver for decisions on implementation. An initial study of an RTS, S vaccine candidate showed promising efficacy against severe malaria in children in Mozambique. Further evidence of its protective efficacy will be gained in a pivotal, multi-centre, phase III study. This paper describes the case definitions of severe malaria used in this study and the programme for standardized assessment of severe malaria according to the case definition. Case definitions of severe malaria were developed from a literature review and a consensus meeting of expert consultants and the RTS, S Clinical Trial Partnership Committee, in collaboration with the World Health Organization and the Malaria Clinical Trials Alliance. The same groups, with input from an Independent Data Monitoring Committee, developed and implemented a programme for standardized data collection.The case definitions developed reflect the typical presentations of severe malaria in African hospitals. Markers of disease severity were chosen on the basis of their association with poor outcome, occurrence in a significant proportion of cases and on an ability to standardize their measurement across research centres. For the primary case definition, one or more clinical and/or laboratory markers of disease severity have to be present, four major co-morbidities (pneumonia, meningitis, bacteraemia or gastroenteritis with severe dehydration) are excluded, and a Plasmodium falciparum parasite density threshold is introduced, in order to maximize the specificity of the case definition. Secondary case definitions allow inclusion of co-morbidities and/or allow for the presence of parasitaemia at any density. The programmatic implementation of standardized case assessment included a clinical algorithm for evaluating seriously sick children

  11. Standard mirror fusion reactor design study

    International Nuclear Information System (INIS)

    Moir, R.W.

    1978-01-01

    This report covers the work of the Magnetic Fusion Energy Division's reactor study group during FY 1976 on the standard mirror reactor. The ''standard'' mirror reactor is characterized as a steady state, neutral beam sustained, D-T fusioning plasma confined by a Yin-Yang magnetic mirror field. The physics parameters are obtained from the same physics model that explains the 2XIIB experiment. The model assumes that the drift cyclotron loss cone mode occurs on the boundary of the plasma, and that it is stabilized by warm plasma with negligible energy investment. The result of the study was a workable mirror fusion power plant, steady-state blanket removal made relatively simple by open-ended geometry, and no impurity problem due to the positive plasma potential. The Q (fusion power/injected beam power) turns out to be only 1.1 because of loss out the ends from Coulomb collisions, i.e., classical losses. This low Q resulted in 77% of the gross electrical power being used to power the injectors, thereby causing the net power cost to be high. The low Q stimulated an intensive search for Q-enhancement concepts, resulting in the LLL reactor design effort turning to the field reversal mirror and the tandem mirror, each having Q of order 5

  12. National and international standards and recommendations on fire protection and fire safety assessment

    International Nuclear Information System (INIS)

    Berg, H.P.

    2007-01-01

    Experience feedback from events in nuclear facilities worldwide has shown that fire can represent a safety significant hazard. Thus, the primary objectives of fire protection programmes are to minimize both the probability of occurrence and the consequences of a fire. The regulator body expects that the licensees justify their arrangements for identifying how fires can occur and spread, assess the vulnerability of plant equipment and structures, determine how the safe operation of a plant is affected, and introduce measures to prevent a fire hazard from developing and propagating as well as to mitigate its effects in case the fire cannot be prevented. For that purpose usually a comprehensive regulatory framework for fire protection has been elaborated, based on national industrial regulations, nuclear specific regulations as well as international recommendations or requirements. Examples of such national and international standards and recommendations on fire protection and fire safety assessment as well as ongoing activities in this field are described. (orig.)

  13. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Energy Technology Data Exchange (ETDEWEB)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L [Clinical Physics Laboratory-833, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); De Boode, W P [Neonatology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Huisman, H J [Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Kapusta, L [Pediatric Cardiology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)], E-mail: m.m.nillesen@cukz.umcn.nl

    2009-04-07

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  14. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    International Nuclear Information System (INIS)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L; De Boode, W P; Huisman, H J; Kapusta, L

    2009-01-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  15. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Science.gov (United States)

    Nillesen, M. M.; Lopata, R. G. P.; de Boode, W. P.; Gerrits, I. H.; Huisman, H. J.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2009-04-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  16. The Wada Test: contributions to standardization of the stimulus for language and memory assessment

    Directory of Open Access Journals (Sweden)

    Mäder Maria Joana

    2004-01-01

    Full Text Available The Wada Test (WT is part of the presurgical evaluation for refractory epilepsy. The WT is not standardized and the protocols differ in important ways, including stimulus type of material presented for memory testing, timing of presentations and methods of assessment. The aim of this study was to contribute to establish parameters for a WT to Brazilian population investigating the performance of 100 normal subjects, without medication. Two parallel models were used based on Montreal Procedure adapted from Gail Risse's (MEG-MN,EUA protocol. The proportions of correct responses of normal subjects submitted to two parallel WT models were investigated and the two models were compared. The results showed that the two models are similar but significant differences among the stimulus type were observed. The results suggest that the stimulus type may influence the results of the WT and should be considered when constructing models and comparing different protocols.

  17. The German Adaptation and Standardization of the Personality Assessment Inventory (PAI).

    Science.gov (United States)

    Groves, Julia A; Engel, Rolf R

    2007-02-01

    We developed the German Adaptation of the Personality Assessment Inventory (PAI; Morey, 1991) under careful consideration of current adaptation literature and guidelines. The adaptation process included the translation of the 344 items into German, a back translation into English as well as the testing of the language equivalence using a bilingual sample. We then standardized the final German version of the PAI for the German population. We compared the American and German norm and reliability data. The observed differences in PAI scale means did not exceed 5 T scores. Internal consistency reliability showed a similar pattern in both language versions, although the German alpha coefficients were on average slightly lower than the American ones. Factor structure was similar in both versions. We discuss expectations about the German PAI and possible problems for its practical usefulness for the German-speaking population.

  18. Satisfying the needs of Japanese cancer patients: a comparative study of detailed and standard informed consent documents.

    Science.gov (United States)

    Sato, Keiko; Watanabe, Toru; Katsumata, Noriyuki; Sato, Tosiya; Ohashi, Yasuo

    2014-02-01

    Simplified informed consent forms have been successful in improving patient satisfaction and decreasing patient anxiety. However, unsolved problems remain about whether these documents improve comprehension and satisfaction of patients with standard literacy skills. s To investigate whether a detailed consent form explaining the key elements of informed consent, in comparison to a standard consent form, would increase the comprehension and satisfaction of adult cancer patients. Patients who were eligible for the National Surgical Adjuvant Study of Breast Cancer (protocol 01(N-SAS/BC-01)) were randomly selected to receive one of the following four versions: detailed document with graphics, detailed document without graphics, standard document with graphics, and standard document without graphics. The forms were written in plain language from the patients' point of view. A total of 85 patients were administered questionnaires via interview to assess levels of comprehension, satisfaction, and anxiety. Patients demonstrated a strong understanding of information regarding treatment and research. Patient comprehension did not differ significantly between the detailed document arms and the standard document arms. Patient satisfaction level increased according to the amount of information presented in the consent form; most patients preferred the detailed document with graphics. Anxiety and accrual rates in the parent study were not affected by informed consent procedures. Findings were limited to adults who had standard literacy skills and may not be generalizable to a population with lower literacy. Informed consent can be a significant experience for a population with standard literacy skills, as long as the document is easily comprehensible. Such information should be provided in a format that corresponds with patient needs, education levels, and preferences.

  19. Using standardized methods for research on HIV and injecting drug use in developing/transitional countries: case study from the WHO Drug Injection Study Phase II

    Directory of Open Access Journals (Sweden)

    Stimson Gerry V

    2006-03-01

    Full Text Available Abstract Background Successful cross-national research requires methods that are both standardized across sites and adaptable to local conditions. We report on the development and implementation of the methodology underlying the survey component of the WHO Drug Injection Study Phase II – a multi-site study of risk behavior and HIV seroprevalence among Injecting Drug Users (IDUs. Methods Standardized operational guidelines were developed by the Survey Coordinating Center in collaboration with the WHO Project Officer and participating site Investigators. Throughout the duration of the study, survey implementation at the local level was monitored by the Coordinating Center. Surveys were conducted in 12 different cities. Prior rapid assessment conducted in 10 cities provided insight into local context and guided survey implementation. Where possible, subjects were recruited both from drug abuse treatment centers and via street outreach. While emphasis was on IDUs, non-injectors were also recruited in cities with substantial non-injecting use of injectable drugs. A structured interview and HIV counseling/testing were administered. Results Over 5,000 subjects were recruited. Subjects were recruited from both drug treatment and street outreach in 10 cities. Non-injectors were recruited in nine cities. Prior rapid assessment identified suitable recruitment areas, reduced drug users' distrust of survey staff, and revealed site-specific risk behaviors. Centralized survey coordination facilitated local questionnaire modification within a core structure, standardized data collection protocols, uniform database structure, and cross-site analyses. Major site-specific problems included: questionnaire translation difficulties; locating affordable HIV-testing facilities; recruitment from drug treatment due to limited/selective treatment infrastructure; access to specific sub-groups of drug users in the community, particularly females or higher income groups

  20. Standard setting: Comparison of two methods

    Directory of Open Access Journals (Sweden)

    Oyebode Femi

    2006-09-01

    Full Text Available Abstract Background The outcome of assessments is determined by the standard-setting method used. There is a wide range of standard – setting methods and the two used most extensively in undergraduate medical education in the UK are the norm-reference and the criterion-reference methods. The aims of the study were to compare these two standard-setting methods for a multiple-choice question examination and to estimate the test-retest and inter-rater reliability of the modified Angoff method. Methods The norm – reference method of standard -setting (mean minus 1 SD was applied to the 'raw' scores of 78 4th-year medical students on a multiple-choice examination (MCQ. Two panels of raters also set the standard using the modified Angoff method for the same multiple-choice question paper on two occasions (6 months apart. We compared the pass/fail rates derived from the norm reference and the Angoff methods and also assessed the test-retest and inter-rater reliability of the modified Angoff method. Results The pass rate with the norm-reference method was 85% (66/78 and that by the Angoff method was 100% (78 out of 78. The percentage agreement between Angoff method and norm-reference was 78% (95% CI 69% – 87%. The modified Angoff method had an inter-rater reliability of 0.81 – 0.82 and a test-retest reliability of 0.59–0.74. Conclusion There were significant differences in the outcomes of these two standard-setting methods, as shown by the difference in the proportion of candidates that passed and failed the assessment. The modified Angoff method was found to have good inter-rater reliability and moderate test-retest reliability.

  1. Assessing the National Bioengineered Food Disclosure Standard of 2016: Can Americans Access Electronic Disclosure Information?

    Directory of Open Access Journals (Sweden)

    Craig F. Berning

    2017-05-01

    Full Text Available The debate as to whether to require mandatory labeling of genetically modified organism (GMO foods was partially settled on 29 July 2016, when President Obama signed the National Bioengineered Food Disclosure Standard into public law. In contrast to precipitating legislation passed by the State of Vermont that required disclosure of GMO ingredients on food shelves or food packages, the superseding National Standard allows firms to disclose bioengineered ingredients to consumers via symbols, electronic or digital links, or phone numbers, and further requires a study assessing the ability of consumers to access disclosure information by these means. This communication analyzes survey responses from 525 adults to investigate whether U.S. consumers are able to obtain information as per the disclosure methods allowed in the Federal legislation. The survey probes deeper to investigate consumer perceptions of genetically modified organisms and whether consumers would use the tools available to access disclosure about bioengineered ingredients. Findings from the survey show that 93.8% of respondents have the ability to access information via the disclosure methods permitted. Those in the lowest income group, and from the oldest age group are least likely to have such access. This provides the United State Department of Agriculture with information relevant to how they can implement the law and highlights particular demographic segments that may require additional attention to ensure the disclosed information is universally accessible.

  2. Development and Application of Assessment Standards to Advanced Written Assignments

    Science.gov (United States)

    Miihkinen, Antti; Virtanen, Tuija

    2018-01-01

    This study describes the results of a project that focused on developing an assessment rubric to be used as the assessment criteria for the written thesis of accounting majors and the quality of the coursework during the seminar. We used descriptive analysis and the survey method to collect information for the development work and to examine the…

  3. Mixed deep learning and natural language processing method for fake-food image recognition and standardization to help automated dietary assessment.

    Science.gov (United States)

    Mezgec, Simon; Eftimov, Tome; Bucher, Tamara; Koroušić Seljak, Barbara

    2018-04-06

    The present study tested the combination of an established and a validated food-choice research method (the 'fake food buffet') with a new food-matching technology to automate the data collection and analysis. The methodology combines fake-food image recognition using deep learning and food matching and standardization based on natural language processing. The former is specific because it uses a single deep learning network to perform both the segmentation and the classification at the pixel level of the image. To assess its performance, measures based on the standard pixel accuracy and Intersection over Union were applied. Food matching firstly describes each of the recognized food items in the image and then matches the food items with their compositional data, considering both their food names and their descriptors. The final accuracy of the deep learning model trained on fake-food images acquired by 124 study participants and providing fifty-five food classes was 92·18 %, while the food matching was performed with a classification accuracy of 93 %. The present findings are a step towards automating dietary assessment and food-choice research. The methodology outperforms other approaches in pixel accuracy, and since it is the first automatic solution for recognizing the images of fake foods, the results could be used as a baseline for possible future studies. As the approach enables a semi-automatic description of recognized food items (e.g. with respect to FoodEx2), these can be linked to any food composition database that applies the same classification and description system.

  4. Minimum Wage and Maximum Hours Standards Under the Fair Labor Standards Act. Economic Effects Studies.

    Science.gov (United States)

    Wage and Labor Standards Administration (DOL), Washington, DC.

    This report describes the 1966 amendments to the Fair Labor Standards Act and summarizes the findings of three 1969 studies of the economic effects of these amendments. The studies found that economic growth continued through the third phase of the amendments, beginning February 1, 1969, despite increased wage and hours restrictions for recently…

  5. Assessment of service quality of public antiretroviral treatment (ART clinics in South Africa: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Kinkel Hans F

    2012-07-01

    Full Text Available Abstract Background In South Africa the ever increasing demand for antiretroviral treatment (ART runs the risk of leading to sub-optimal care in public sector ART clinics that are overburdened and under resourced. This study assessed the quality of ART services to identify service areas that require improvement. Methods A cross-sectional study was carried out at 16 of 17 public ART clinics in the target area in greater Pretoria, South Africa. Trained participant observers presented as ART qualifying HIV positive patients that required a visit to assess treatment readiness. They evaluated each facility on five different occasions between June and November 2009, assessing the time it took to get an appointment, the services available and accessed, service quality and the duration of the visit. Services (reception area, clinician’s consultation, HIV counselling, pharmacy, nutrition counselling and social worker’s assessment were assessed against performance standards that apply to all clinics. Service quality was expressed as scores for clinic performance (CPS and service performance (SPS, defined as the percentage of performance standards met per clinic and service area. Results In most of the clinics (62.5% participant observers were able to obtain an appointment within one week, although on the day of their visit essential services could not always be accessed. The median CPS of the assessed facilities was 68.5 with four clinics not meeting minimum standards (CPS > 60. The service areas that performed least well were the clinician’s consultation (SPS 67.3 and HIV counselling (SPS 70.7. Most notably, clinicians performed a physical examination in only 41.1% of the visits and rarely did a complete TB symptom screening. Counsellors frequently failed to address prevention of HIV transmission. Conclusions Overall public sector ART clinics in greater Pretoria were easily accessible and their services were of an acceptable quality. However

  6. Pharmacognostic standardization and preliminary phytochemical studies of Gaultheria trichophylla.

    Science.gov (United States)

    Alam, Fiaz; Najum us Saqib, Qazi

    2015-01-01

    Gaultheria trichophylla Royle (Ericaceae) has long been used for various ailments in traditional systems of medicines; most importantly it is used against pain and inflammation. This study determines various pharmacognostic and phytochemical standards helpful to ensure the purity, safety, and efficacy of medicinal plant G. trichophylla. Intact aerial parts, powdered materials, and extracts were examined macro- and microscopically and pharmacognostic standardization parameters were determined in accordance with the guidelines given by the World Health Organization (WHO). Parameters including extractive values, ash values, and loss on drying were determined. Preliminary phytochemical tests, fluorescence analysis, and chromatographic profiling were performed for the identification and standardization of G. trichophylla. The shape, size, color, odor, and surface characteristics were noted for intact drug and powdered drug material of G. trichophylla. Light and scanning electron microscope images of cross section of leaf and powdered microscopy revealed useful diagnostic features. Histochemical, phytochemical, physicochemical, and fluorescence analysis proved useful tools to differentiate the powdered drug material. High-performance liquid chromatography (HPLC) analysis showed the presence of important phytoconstituents such as gallic acid, rutin, and quercetin. The data generated from the present study help to authenticate the medicinally important plant G. trichophylla. Qualitative and quantitative microscopic features may be helpful for establishing the pharmacopeia standards. Morphology as well as various pharmacognostic aspects of different parts of the plant were studied and described along with phytochemical and physicochemical parameters, which could be helpful in further isolation and purification of medicinally important compounds.

  7. Physical fitness reference standards in European children: the IDEFICS study.

    Science.gov (United States)

    De Miguel-Etayo, P; Gracia-Marco, L; Ortega, F B; Intemann, T; Foraita, R; Lissner, L; Oja, L; Barba, G; Michels, N; Tornaritis, M; Molnár, D; Pitsiladis, Y; Ahrens, W; Moreno, L A

    2014-09-01

    A low fitness status during childhood and adolescence is associated with important health-related outcomes, such as increased future risk for obesity and cardiovascular diseases, impaired skeletal health, reduced quality of life and poor mental health. Fitness reference values for adolescents from different countries have been published, but there is a scarcity of reference values for pre-pubertal children in Europe, using harmonised measures of fitness in the literature. The IDEFICS study offers a good opportunity to establish normative values of a large set of fitness components from eight European countries using common and well-standardised methods in a large sample of children. Therefore, the aim of this study is to report sex- and age-specific fitness reference standards in European children. Children (10,302) aged 6-10.9 years (50.7% girls) were examined. The test battery included: the flamingo balance test, back-saver sit-and-reach test (flexibility), handgrip strength test, standing long jump test (lower-limb explosive strength) and 40-m sprint test (speed). Moreover, cardiorespiratory fitness was assessed by a 20-m shuttle run test. Percentile curves for the 1st, 3rd, 10th, 25th, 50th, 75th, 90th, 97th and 99th percentiles were calculated using the General Additive Model for Location Scale and Shape (GAMLSS). Our results show that boys performed better than girls in speed, lower- and upper-limb strength and cardiorespiratory fitness, and girls performed better in balance and flexibility. Older children performed better than younger children, except for cardiorespiratory fitness in boys and flexibility in girls. Our results provide for the first time sex- and age-specific physical fitness reference standards in European children aged 6-10.9 years.

  8. Cognitive assessment in Amyotrophic Lateral Sclerosis by means of P300-Brain Computer Interface: a preliminary study.

    Science.gov (United States)

    Poletti, Barbara; Carelli, Laura; Solca, Federica; Lafronza, Annalisa; Pedroli, Elisa; Faini, Andrea; Zago, Stefano; Ticozzi, Nicola; Meriggi, Paolo; Cipresso, Pietro; Lulé, Dorothée; Ludolph, Albert C; Riva, Giuseppe; Silani, Vincenzo

    To investigate the use of P300-based Brain Computer Interface (BCI) technology for the administration of motor-verbal free cognitive tests in Amyotrophic Lateral Sclerosis (ALS). We recruited 15 ALS patients and 15 age- and education-matched healthy subjects. All participants underwent a BCI-based neuropsychological assessment, together with two standard cognitive screening tools (FAB, MoCA), two psychological questionnaires (BDI, STAI-Y) and a usability questionnaire. For patients, clinical and respiratory examinations were also performed, together with a behavioural assessment (FBI). Correlations were observed between standard cognitive and BCI-based neuropsychological assessment, mainly concerning execution times in the ALS group. Moreover, patients provided positive rates concerning the BCI perceived usability and subjective experience. Finally, execution times at the BCI-based neuropsychological assessment were useful to discriminate patients from controls, with patients achieving lower processing speed than controls regarding executive functions. The developed motor-verbal free neuropsychological battery represents an innovative approach, that could provide relevant information for clinical practice and ethical issues. Its use for cognitive evaluation throughout the course of ALS, currently not available by means of standard assessment, must be addressed in further longitudinal validation studies. Further work will be aimed at refining the developed system and enlarging the cognitive spectrum investigated.

  9. Pilot study: EatFit impacts sixth graders' academic performance on achievement of mathematics and english education standards.

    Science.gov (United States)

    Shilts, Mical Kay; Lamp, Cathi; Horowitz, Marcel; Townsend, Marilyn S

    2009-01-01

    Investigate the impact of a nutrition education program on student academic performance as measured by achievement of education standards. Quasi-experimental crossover-controlled study. California Central Valley suburban elementary school (58% qualified for free or reduced-priced lunch). All sixth-grade students (n = 84) in the elementary school clustered in 3 classrooms. 9-lesson intervention with an emphasis on guided goal setting and driven by the Social Cognitive Theory. Multiple-choice survey assessing 5 education standards for sixth-grade mathematics and English at 3 time points: baseline (T1), 5 weeks (T2), and 10 weeks (T3). Repeated measures, paired t test, and analysis of covariance. Changes in total scores were statistically different (P academic performance measured by achievement of specific mathematics and English education standards. Nutrition educators can show school administrators and wellness committee members that this program can positively impact academic performance, concomitant to its primary objective of promoting healthful eating and physical activity.

  10. A case-control study assessing depression in patients with periodontitis

    Directory of Open Access Journals (Sweden)

    Shiyamali Sundararajan

    2017-01-01

    Full Text Available Background: Chronic periodontitis is an inflammatory disease of the supporting structures of the tooth. One of the important non-oral risk factors for periodontitis is psychosocial stress and depression. Depression affects oral health by affecting the immune system through its effects on hypothalamic pituitary axis system. Periodontal inflammatory surface area (PISA is a system used to assess inflammatory burden in the periodontal tissue. Aim: The aim of this study is to assess the relationship between PISA and depression. Settings and Design: The design of the study is case-control study. Materials and Methods: The study design is a case-control study with forty patients each in case and control groups. The periodontal inflammatory level was assessed by PISA system and the levels of depression was assessed by using Beck's Depression Inventory (BDI. Statistical Analysis: Student's t-test was used to compare PISA and BDI scores. The BDI score (mean ± standard deviation [SD] for controls was 12.75 ± 6.82 compared to 22.73 ± 4.40 for the cases. The comparison (t = 7.78 was statistically significant at P < 0.0001. The PISA score (mean ± SD for controls was 210.47 ± 76.80 compared to the PISA score of 1069.50 ± 204.21 for cases which was statistically significant (t = 24.90; P < 0.0001. Results: Significantly higher BDI scores were observed in patients with chronic periodontitis than healthy controls. Conclusion: This study clearly reveals a significant association between the severity of depression and inflammatory burden.

  11. Assessing the performance and satisfaction of medical residents utilizing standardized patient versus mannequin-simulated training

    Directory of Open Access Journals (Sweden)

    Alsaad AA

    2017-07-01

    Full Text Available Ali A Alsaad,1 Swetha Davuluri,2 Vandana Y Bhide,3 Amy M Lannen,4 Michael J Maniaci3 1Department of Internal Medicine, Mayo Clinic, 2University of Miami, Coral Gables, 3Division of Hospital Internal Medicine, 4J. Wayne and Delores Barr Weaver Simulation Center, Mayo Clinic, Jacksonville, FL, USA Background: Conducting simulations of rapidly decompensating patients are a key part of internal medicine (IM residency training. Traditionally, mannequins have been the simulation tool used in these scenarios. Objective: To compare IM residents’ performance and assess realism in specific-simulated decompensating patient scenarios using standardized patients (SPs as compared to mannequin. Methods: Nineteen IM residents were randomized to undergo simulations using either a mannequin or an SP. Each resident in the two groups underwent four different simulation scenarios (calcium channel blocker overdose, severe sepsis, severe asthma exacerbation, and acute bacterial meningitis. Residents completed pretest and post-test evaluations as well as a questionnaire to assess the reality perception (realism score. Results: Nine residents completed mannequin-based scenarios, whereas 10 completed SP-based scenarios. Improvement in the post-test scores was seen in both groups. However, there were significantly higher post-test scores achieved with SP simulations in three out of the four scenarios (P=0.01. When compared with the mannequin group, the SP simulation group showed a significantly higher average realism score (P=0.002. Conclusions: Applying SP-based specific-simulation scenarios in IM residency training may result in better performance and a higher sense of a realistic experience by medical residents. Keywords: simulation, standardized patient, satisfaction, mannequin, assessment, resident education

  12. Outcome after polytrauma in a certified trauma network: comparing standard vs. maximum care facilities concept of the study and study protocol (POLYQUALY).

    Science.gov (United States)

    Koller, Michael; Ernstberger, Antonio; Zeman, Florian; Loss, Julika; Nerlich, Michael

    2016-07-11

    The aim of this study is to evaluate the performance of the first certified regional trauma network in Germany, the Trauma Network Eastern Bavaria (TNO) addressing the following specific research questions: Do standard and maximum care facilities produce comparable (risk-adjusted) levels of patient outcome? Does TNO outperform reference data provided by the German Trauma Register 2008? Does TNO comply with selected benchmarks derived from the S3 practice guideline? Which barriers and facilitators can be identified in the health care delivery processes for polytrauma patients? The design is based on a prospective multicenter cohort study comparing two cohorts of polytrauma patients: those treated in maximum care facilities and those treated in standard care facilities. Patient recruitment will take place in the 25 TNO clinics. It is estimated that n = 1.100 patients will be assessed for eligibility within a two-year period and n = 800 will be included into the study and analysed. Main outcome measures include the TraumaRegisterQM form, which has been implemented in the clinical routine since 2009 and is filled in via a web-based data management system in participating hospitals on a mandatory basis. Furthermore, patient-reported outcome is assessed using the EQ-5D at 6, 12 and 24 months after trauma. Comparisons will be drawn between the two cohorts. Further standards of comparisons are secondary data derived from German Trauma Registry as well as benchmarks from German S3 guideline on polytrauma. The qualitative part of the study will be based on semi-standardized interviews and focus group discussions with health care providers within TNO. The goal of the qualitative analysis is to elucidate which facilitating and inhibiting forces influence cooperation and performance within the network. This is the first study to evaluate a certified trauma network within the German health care system using a unique combination of a quantitative (prospective cohort

  13. Development of a Standardized Kalamazoo Communication Skills Assessment Tool for Radiologists: Validation, Multisource Reliability, and Lessons Learned.

    Science.gov (United States)

    Brown, Stephen D; Rider, Elizabeth A; Jamieson, Katherine; Meyer, Elaine C; Callahan, Michael J; DeBenedectis, Carolynn M; Bixby, Sarah D; Walters, Michele; Forman, Sara F; Varrin, Pamela H; Forbes, Peter; Roussin, Christopher J

    2017-08-01

    The purpose of this study was to develop and test a standardized communication skills assessment instrument for radiology. The Delphi method was used to validate the Kalamazoo Communication Skills Assessment instrument for radiology by revising and achieving consensus on the 43 items of the preexisting instrument among an interdisciplinary team of experts consisting of five radiologists and four nonradiologists (two men, seven women). Reviewers assessed the applicability of the instrument to evaluation of conversations between radiology trainees and trained actors portraying concerned parents in enactments about bad news, radiation risks, and diagnostic errors that were video recorded during a communication workshop. Interrater reliability was assessed by use of the revised instrument to rate a series of enactments between trainees and actors video recorded in a hospital-based simulator center. Eight raters evaluated each of seven different video-recorded interactions between physicians and parent-actors. The final instrument contained 43 items. After three review rounds, 42 of 43 (98%) items had an average rating of relevant or very relevant for bad news conversations. All items were rated as relevant or very relevant for conversations about error disclosure and radiation risk. Reliability and rater agreement measures were moderate. The intraclass correlation coefficient range was 0.07-0.58; mean, 0.30; SD, 0.13; and median, 0.30. The range of weighted kappa values was 0.03-0.47; mean, 0.23; SD, 0.12; and median, 0.22. Ratings varied significantly among conversations (χ 2 6 = 1186; p communication skills assessment instrument is highly relevant for radiology, having moderate interrater reliability. These findings have important implications for assessing the relational competencies of radiology trainees.

  14. Prospective randomized study comparing coronary artery bypass grafting with the new mini-extracorporeal circulation Jostra System or with a standard cardiopulmonary bypass.

    Science.gov (United States)

    Remadi, Jean Paul; Rakotoarivelo, Zava; Marticho, Paul; Benamar, Amar

    2006-01-01

    To assess the potential benefits of a new concept of cardiopulmonary bypass (CPB), the mini-extracorporeal circulation (MECC) Jostra System, we conducted a prospective randomized study among patients who underwent coronary artery bypass grafting (CABG) with a MECC Jostra System or with a standard CPB. In a prospective randomized study, 400 patients underwent elective CABG using a standard CPB (200 patients) or a Jostra MECC System (200 patients). The patients were randomly assigned to have preoperative data similar for both groups. The operative mortality rate (system is a new concept of CPB that seems to be reliable and safe. To perform CABG, the MECC provides an excellent surgical exposure like a standard CPB and a better biologic profile like CABG without CPB.

  15. Why standard brain-computer interface (BCI) training protocols should be changed: an experimental study

    Science.gov (United States)

    Jeunet, Camille; Jahanpour, Emilie; Lotte, Fabien

    2016-06-01

    Objective. While promising, electroencephaloraphy based brain-computer interfaces (BCIs) are barely used due to their lack of reliability: 15% to 30% of users are unable to control a BCI. Standard training protocols may be partly responsible as they do not satisfy recommendations from psychology. Our main objective was to determine in practice to what extent standard training protocols impact users’ motor imagery based BCI (MI-BCI) control performance. Approach. We performed two experiments. The first consisted in evaluating the efficiency of a standard BCI training protocol for the acquisition of non-BCI related skills in a BCI-free context, which enabled us to rule out the possible impact of BCIs on the training outcome. Thus, participants (N = 54) were asked to perform simple motor tasks. The second experiment was aimed at measuring the correlations between motor tasks and MI-BCI performance. The ten best and ten worst performers of the first study were recruited for an MI-BCI experiment during which they had to learn to perform two MI tasks. We also assessed users’ spatial ability and pre-training μ rhythm amplitude, as both have been related to MI-BCI performance in the literature. Main results. Around 17% of the participants were unable to learn to perform the motor tasks, which is close to the BCI illiteracy rate. This suggests that standard training protocols are suboptimal for skill teaching. No correlation was found between motor tasks and MI-BCI performance. However, spatial ability played an important role in MI-BCI performance. In addition, once the spatial ability covariable had been controlled for, using an ANCOVA, it appeared that participants who faced difficulty during the first experiment improved during the second while the others did not. Significance. These studies suggest that (1) standard MI-BCI training protocols are suboptimal for skill teaching, (2) spatial ability is confirmed as impacting on MI-BCI performance, and (3) when faced

  16. Standards for Academic and Professional Instruction in Foundations of Education, Educational Studies, and Educational Policy Studies Third Edition, 2012, Draft Presented to the Educational Community by the American Educational Studies Association's Committee on Academic Standards and Accreditation

    Science.gov (United States)

    Tutwiler, Sandra Winn; deMarrais, Kathleen; Gabbard, David; Hyde, Andrea; Konkol, Pamela; Li, Huey-li; Medina, Yolanda; Rayle, Joseph; Swain, Amy

    2013-01-01

    This third edition of the "Standards for Academic and Professional Instruction in Foundations of Education, Educational Studies, and Educational Policy Studies" is presented to the educational community by the American Educational Studies Association's Committee on Academic Standards and Accreditation. The Standards were first developed and…

  17. Cross-Cultural Aspect of Behavior Assessment System for Children-2, Parent Rating Scale-Child: Standardization in Korean Children

    Science.gov (United States)

    Song, Jungeun; Leventhal, Bennett L.; Koh, Yun-Joo; Cheon, Keun-Ah; Hong, Hyun Ju; Kim, Young-Key; Cho, Kyungjin; Lim, Eun-Chung; Park, Jee In

    2017-01-01

    Purpose Our study aimed to examine psychometric properties and cross-cultural utility of the Behavior Assessment System for Children-2, Parent Rating Scale-Child (BASC-2 PRS-C) in Korean children. Materials and Methods Two study populations were recruited: a general population sample (n=2115) of 1st to 6th graders from 16 elementary schools and a clinical population (n=219) of 6–12 years old from 5 child psychiatric clinics and an epidemiological sample of autism spectrum disorder. We assessed the validity and reliability of the Korean version of BASC-2 PRS-C (K-BASC-2 PRS-C) and compared subscales with those used for US populations. Results Our results indicate that the K-BASC-2 PRS-C is a valuable instrument with reliability and validity for measuring developmental psychopathology that is comparable to those in Western population. However, there were some differences noted in the mean scores of BASC-2 PRS-C between Korean and US populations. Conclusion K-BASC-2 PRS-C is an effective and useful instrument with psychometric properties that permits measurement of general developmental psychopathology. Observed Korean-US differences in patterns of parental reports of children's behaviors indicate the importance of the validation, standardization and cultural adaptation for tools assessing psychopathology especially when used in populations different from those for which the instrument was originally created. PMID:28120577

  18. Cross-Cultural Aspect of Behavior Assessment System for Children-2, Parent Rating Scale-Child: Standardization in Korean Children.

    Science.gov (United States)

    Song, Jungeun; Leventhal, Bennett L; Koh, Yun Joo; Cheon, Keun Ah; Hong, Hyun Ju; Kim, Young Key; Cho, Kyungjin; Lim, Eun Chung; Park, Jee In; Kim, Young Shin

    2017-03-01

    Our study aimed to examine psychometric properties and cross-cultural utility of the Behavior Assessment System for Children-2, Parent Rating Scale-Child (BASC-2 PRS-C) in Korean children. Two study populations were recruited: a general population sample (n=2115) of 1st to 6th graders from 16 elementary schools and a clinical population (n=219) of 6-12 years old from 5 child psychiatric clinics and an epidemiological sample of autism spectrum disorder. We assessed the validity and reliability of the Korean version of BASC-2 PRS-C (K-BASC-2 PRS-C) and compared subscales with those used for US populations. Our results indicate that the K-BASC-2 PRS-C is a valuable instrument with reliability and validity for measuring developmental psychopathology that is comparable to those in Western population. However, there were some differences noted in the mean scores of BASC-2 PRS-C between Korean and US populations. K-BASC-2 PRS-C is an effective and useful instrument with psychometric properties that permits measurement of general developmental psychopathology. Observed Korean-US differences in patterns of parental reports of children's behaviors indicate the importance of the validation, standardization and cultural adaptation for tools assessing psychopathology especially when used in populations different from those for which the instrument was originally created.

  19. Competitive Debate as Competency-Based Learning: Civic Engagement and Next-Generation Assessment in the Era of the Common Core Learning Standards

    Science.gov (United States)

    McIntosh, Jonathan; Milam, Myra

    2016-01-01

    As the adoption and execution of the Common Core State Standards (CCSS) have steadily increased, the debate community is presented with an opportunity to be more forward thinking and sustainable through the translation to curriculum planning and next-generation assessment as a movement towards Performance-Based Assessments. This paper focuses on…

  20. assess the impact of Warana co-operative complex on the standard ...

    African Journals Online (AJOL)

    `123456789jkl''''#

    Ethiopian Journal of Environmental Studies and Management Vol.2 No.3 2009. 1Dept of ... Abstract. The present paper, mainly based on the primary data, attempts to analyze the standard of living of people in .... prevailing; so that a large proportion of people are under ... activities before the industrial revolution. The.

  1. Do newspaper reports of suicides comply with standard suicide reporting guidelines? A study from Bangalore, India.

    Science.gov (United States)

    Chandra, Prabha S; Doraiswamy, Padmavathy; Padmanabh, Anuroopa; Philip, Mariamma

    2014-11-01

    Several countries have prescribed standard guidelines for media professionals on suicide reporting. However, the implementation of these guidelines has been varied. Suicide rates in South Asia are one of the highest in the world, and it is known that media guidelines for suicide reporting are not followed adequately. However, there are no published reports available from this region. This study aimed at assessing newspaper reports of suicide for quality of reporting based on standard reporting guidelines and to study differences between English and vernacular (Kannada) newspapers in Bangalore, South India. A total of 341 newspaper reports of suicide from 550 newspapers (3 English and 3 Kannada) over 3 months were systematically assessed for compliance with reporting guidelines. Each report was evaluated on 2 domains and 36 parameters. Data were analyzed for frequency of inappropriate reporting and patterns compared between vernacular and English newspapers. In all, 87% of the reports were those of completed suicide. Non-compliant reporting - method of suicide was reported in 89% and 32% of reports were in prominent pages of the newspaper, 95% mentioned gender, 90% reported the name, 80% reported age and suicide location, 75% reported life events related to suicide, 70% reported occupation, 69% had headline explicity on suicide and 61% reported monocausality. Only 16% reported mental disorder related to suicide, and less than 3% included information on suicide prevention and helplines. Vernacular papers showed significantly better compliance in 16 of the 20 areas. However, protective characteristics were better reported in English newspapers. Majority of reports on suicides in newspapers from Bangalore did not comply with standard guidelines of reporting. There is a strong need to evolve local guidelines and mechanisms for ensuring responsible reporting which have important implications in prevention of suicide. © The Author(s) 2013.

  2. Risk assessment in infrastructure in educational institution: A study in Malaysia

    Science.gov (United States)

    Rasdan Ismail, Ahmad; Adilah Hamzah, Noor; Kamilah Makhtar, Nor; Azhar Mat Daud, Khairul; Zulkarnaen Khidzir, Nik; Husna Che Hassan, Nurul; Arifpin Mansor, Muhamad

    2017-10-01

    This particular study was conducted to assess the hazard exposure in education institution and to highlight the possible risk level available. The assessment utilised is Hazard Identification, Risk Assessment and Risk Control (HIRARC). There was a 2008’s form in order to determine the risk level of the hazard. There were over 111 of education institutions were selected around Malaysia to perform this assessment. Area chosen for each institution was office, playing field, canteen, classroom, toilet and drainage. By referring HIRARC Guideline 2008, the determination of risk rank is measure based on the formula likelihood multiply severity and the rank need to refer from risk matrix standard. There are several hazard have be found and shows the high, medium and low of risk level. The higher level of risk was discussed in the study which is hazard found in playing field and hazard in office. There several hazard that need to be control by education management to avoid increase of case accident in Education Sector, Malaysia. As conclusion, the exposure hazard among the staff and educators is high and further action and control are needed. Further study need to explore the best recommendation for control measure of the hazard exposed by education institution.

  3. Reaction Time and Attention: Toward a New Standard in the Assessment of ADHD? A Pilot Study.

    Science.gov (United States)

    De la Torre, Gabriel G; Barroso, Juan M; León-Carrión, José; Mestre, Jose M; Bozal, Rocío Guil

    2015-12-01

    This pilot study shows results of an experiment comparing reaction times (RTs) and attentional performance between an ADHD group of 30 children and 30 controls, both Spanish speaking. The experiment was carried out using the Seville computerized neuropsychological battery (SNB). This study had two goals: One was to test sensitivity of SNB for attention deficits in ADHD and the second was to detect differences in RTs between ADHD and controls. Possible explanations and implications of such differences are also discussed. SNB computerized system was used to assess RTs and accuracy, and alternate forms of continuous performance task were used. Results showed high sensitivity of some of the SNB tests, especially cancellation tests. RTs were significantly different between groups. SNB represents a helpful tool for detection of attention deficits, and RT indices represent the most significant variable in differentiation of both groups studied. © The Author(s) 2012.

  4. Continuous evaluation of midwives as to professional standards

    Directory of Open Access Journals (Sweden)

    ZAHRA YAZDANPANAHI

    2013-07-01

    Full Text Available Introduction: Implementation of professional standards as well as evaluation and assessments of providers has an important role in health promotion of each society. The purpose of this study was to assess the midwives working at midwifery offices as to performance of professional standards and effectiveness of continuous evaluation and education on them. Methods: This is an interventional study in which all of midwifery offices (110 were evaluated. The study was done in three stages using standard checklist observation and interview in each step. Based on detected errors, appropriate education was done and their performance was reevaluated in the next step of supervision. Finally total scores in each step as well as scores in different subjects were compared among three evaluated stages. Results: Overall mean score of faults at midwifery offices decreased from step 1 to step 3 in the following fields: environmental health and infection control (P<0.0002, personal and patient care (P=0.0005, individual health (P=0.003 and adherence to laws and rules (P<0.0001. Conclusion: Continuous evaluation is essential for assessing the effectiveness and improvement of our educational program. With continuous evaluation, correction of observed defects will be done at an early stage by appropriate intervention and education. So our medical and health programs will attain the planned goals.

  5. An Assessment of the Need for Standard Variable Names for Airborne Field Campaigns

    Science.gov (United States)

    Beach, A. L., III; Chen, G.; Northup, E. A.; Kusterer, J.; Quam, B. M.

    2017-12-01

    The NASA Earth Venture Program has led to a dramatic increase in airborne observations, requiring updated data management practices with clearly defined data standards and protocols for metadata. An airborne field campaign can involve multiple aircraft and a variety of instruments. It is quite common to have different instruments/techniques measure the same parameter on one or more aircraft platforms. This creates a need to allow instrument Principal Investigators (PIs) to name their variables in a way that would distinguish them across various data sets. A lack of standardization of variables names presents a challenge for data search tools in enabling discovery of similar data across airborne studies, aircraft platforms, and instruments. This was also identified by data users as one of the top issues in data use. One effective approach for mitigating this problem is to enforce variable name standardization, which can effectively map the unique PI variable names to fixed standard names. In order to ensure consistency amongst the standard names, it will be necessary to choose them from a controlled list. However, no such list currently exists despite a number of previous efforts to establish a sufficient list of atmospheric variable names. The Atmospheric Composition Variable Standard Name Working Group was established under the auspices of NASA's Earth Science Data Systems Working Group (ESDSWG) to solicit research community feedback to create a list of standard names that are acceptable to data providers and data users This presentation will discuss the challenges and recommendations of standard variable names in an effort to demonstrate how airborne metadata curation/management can be improved to streamline data ingest, improve interoperability, and discoverability to a broader user community.

  6. Developmental Assessment with Young Children: A Systematic Review of Battelle Studies

    Science.gov (United States)

    Cunha, Ana C. B.; Berkovits, Michelle D.; Albuquerque, Karolina A.

    2018-01-01

    Developmental assessment scales are important tools for determining developmental delays and planning preventive interventions. One broad assessment scale used to evaluate child development is the Battelle Developmental Inventories (BDIs). The BDI-2 has a standardized version in English with good psychometric properties and a translated version in…

  7. Psychometric characterization of the obstetric communication assessment tool for medical education: a pilot study.

    Science.gov (United States)

    Rodriguez, A Noel; DeWitt, Peter; Fisher, Jennifer; Broadfoot, Kirsten; Hurt, K Joseph

    2016-06-11

    To characterize the psychometric properties of a novel Obstetric Communication Assessment Tool (OCAT) in a pilot study of standardized difficult OB communication scenarios appropriate for undergraduate medical evaluation. We developed and piloted four challenging OB Standardized Patient (SP) scenarios in a sample of twenty-one third year OB/GYN clerkship students: Religious Beliefs (RB), Angry Father (AF), Maternal Smoking (MS), and Intimate Partner Violence (IPV). Five trained Standardized Patient Reviewers (SPRs) independently scored twenty-four randomized video-recorded encounters using the OCAT. Cronbach's alpha and Intraclass Correlation Coefficient-2 (ICC-2) were used to estimate internal consistency (IC) and inter-rater reliability (IRR), respectively. Systematic variation in reviewer scoring was assessed using the Stuart-Maxwell test. IC was acceptable to excellent with Cronbach's alpha values (and 95% Confidence Intervals [CI]): RB 0.91 (0.86, 0.95), AF 0.76 (0.62, 0.87), MS 0.91 (0.86, 0.95), and IPV 0.94 (0.91, 0.97). IRR was unacceptable to poor with ICC-2 values: RB 0.46 (0.40, 0.53), AF 0.48 (0.41, 0.54), MS 0.52 (0.45, 0.58), and IPV 0.67 (0.61, 0.72). Stuart-Maxwell analysis indicated systematic differences in reviewer stringency. Our initial characterization of the OCAT demonstrates important issues in communications assessment. We identify scoring inconsistencies due to differences in SPR rigor that require enhanced training to improve assessment reliability. We outline a rational process for initial communication tool validation that may be useful in undergraduate curriculum development, and acknowledge that rigorous validation of OCAT training and implementation is needed to create a valuable OB communication assessment tool.

  8. Experimental study of hybrid-knife endoscopic submucosal dissection (ESD versus standard ESD in a Western country

    Directory of Open Access Journals (Sweden)

    Joaquín de-la Peña

    2014-02-01

    Full Text Available Background: Endoscopic submucosal dissection (ESD is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise. Objective: The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with high-pressure water jet and to compare with standard ESD. Material and methods: We performed a prospective non-survival animal study comparing hybrid-knife and standard gastric ESD. Variables recorded were: Number of en-bloc ESD, number of ESD with all marks included (R0, size of specimens, time and speed of dissection and adverse events. Ten endoscopists performed a total of 50 gastric ESD (30 hybrid-knife and 20 standard. Results: Forty-six (92% ESD were en-bloc and 25 (50% R0 (hybrid-knife: n = 13, 44%; standard: n = 16, 80%; p = 0.04. Hybrid-knife ESD was faster than standard (time: 44.6 ± 21.4 minutes vs. 68.7 ± 33.5 minutes; p = 0.009 and velocity: 20.8 ± 9.2 mm²/min vs. 14.3 ± 9.3 mm²/min (p = 0.079. Adverse events were not different. There was no change in speed with any of two techniques (hybrid-knife: From 20.33 ± 15.68 to 28.18 ± 20.07 mm²/min; p = 0.615 and standard: From 6.4 ± 0.3 to 19.48 ± 19.21 mm²/min; p = 0.607. The learning curve showed a significant improvement in R0 rate in the hybrid-knife group (from 30% to 100%. Conclusion: despite the initial performance of hybrid-knife ESD is worse than standard ESD, the learning curve with hybrid-knife ESD is short and is associated with a rapid improvement. The introduction of new tools to facilitate ESD should be implemented with caution in order to avoid a negative impact on the results.

  9. INTERGROWTH-21st Gestational Dating and Fetal and Newborn Growth Standards in Peri-Urban Nairobi, Kenya: Quasi-Experimental Implementation Study Protocol.

    Science.gov (United States)

    Millar, Kathryn; Patel, Suha; Munson, Meghan; Vesel, Linda; Subbiah, Shalini; Jones, Rachel M; Little, Sarah; Papageorghiou, Aris T; Villar, Jose; Wegner, Mary Nell; Pearson, Nick; Muigai, Faith; Ongeti, Catherine; Langer, Ana

    2018-06-22

    The burden of preterm birth, fetal growth impairment, and associated neonatal deaths disproportionately falls on low- and middle-income countries where modern obstetric tools are not available to date pregnancies and monitor fetal growth accurately. The INTERGROWTH-21 st gestational dating, fetal growth monitoring, and newborn size at birth standards make this possible. To scale up the INTERGROWTH-21 st standards, it is essential to assess the feasibility and acceptability of their implementation and their effect on clinical decision-making in a low-resource clinical setting. This study protocol describes a pre-post, quasi-experimental implementation study of the standards at Jacaranda Health, a maternity hospital in peri-urban Nairobi, Kenya. All women with viable fetuses receiving antenatal and delivery services, their resulting newborns, and the clinicians caring for them from March 2016 to March 2018 are included. The study comprises a 12-month preimplementation phase, a 12-month implementation phase, and a 5-month post-implementation phase to be completed in August 2018. Quantitative clinical and qualitative data collected during the preimplementation and implementation phases will be assessed. A clinician survey was administered eight months into the implementation phase, month 20 of the study. Implementation outcomes include quantitative and qualitative analyses of feasibility, acceptability, adoption, appropriateness, fidelity, and penetration of the standards. Clinical outcomes include appropriateness of referral and effect of the standards on clinical care and decision-making. Descriptive analyses will be conducted, and comparisons will be made between pre- and postimplementation outcomes. Qualitative data will be analyzed using thematic coding and compared across time. The study was approved by the Amref Ethics and Scientific Review Committee (Kenya) and the Harvard University Institutional Review Board. Study results will be shared with stakeholders

  10. A study on equivalence assessment of auditing by EU(In Commemoration of the Retirement of Professors Kiichi Kageyama and Yasunori Takagi)

    OpenAIRE

    土屋, 和之; ツチヤ, カズユキ; Kazuyuki, TSUCHIYA

    2007-01-01

    The purpose of this research is examining the impact of equivalence assessment of auditing by European Union on Japanese auditing system. In this assessment International Standards on Auditing and US Generally Accepted Auditing Standards are allowed to be equivalent auditing standards. Japanese auditing standards are not same with ISA, but sre almost equal with ISA. Japanese auditing standards might noy be assessed as equivalent auditing standards.

  11. Equipment standards for interventional cardiology

    International Nuclear Information System (INIS)

    Dowling, A.; Gallagher, A.; Walsh, C.; Malone, J.

    2005-01-01

    Interventional radiology has seen rapid growth in cardiology and represents an alternative to hazardous surgery. Recently there has been a substantial growth in the number of procedures being performed and interventional cardiology (IC) procedures are the most common interventional procedures in Europe. Advances in imaging technology have facilitated the development of increasingly complex radiological IC equipment. Currently, the technology is developing at a rate ahead of supporting research, equipment standards and a regulatory framework. International standards play a key role in the design, manufacture and performance of radiological IC equipment. A survey of 12 IC systems (15 imaging chains) was conducted in Irish hospitals. The aim of the study was to assess the imbalance between rapidly advancing technology and existing standards and to propose recommendations for new IC equipment standards. The results demonstrate the need for definitive equipment requirements and standardisation in the design, manufacture, acceptance and maintenance of IC equipment. (authors)

  12. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    Science.gov (United States)

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  13. Using PISA as an International Benchmark in Standard Setting.

    Science.gov (United States)

    Phillips, Gary W; Jiang, Tao

    2015-01-01

    This study describes how the Programme for International Student Assessment (PISA) can be used to internationally benchmark state performance standards. The process is accomplished in three steps. First, PISA items are embedded in the administration of the state assessment and calibrated on the state scale. Second, the international item calibrations are then used to link the state scale to the PISA scale through common item linking. Third, the statistical linking results are used as part of the state standard setting process to help standard setting panelists determine how high their state standards need to be in order to be internationally competitive. This process was carried out in Delaware, Hawaii, and Oregon, in three subjects-science, mathematics and reading with initial results reported by Phillips and Jiang (2011). An in depth discussion of methods and results are reported in this article for one subject (mathematics) and one state (Hawaii).

  14. Succeeding in process standardization: Explaining the fit with international management strategy

    DEFF Research Database (Denmark)

    Rahimi, Fatemeh; Møller, Charles; Hvam, Lars

    2016-01-01

    Purpose: The purpose of this paper is to explore the fit between process standardization and international management strategy of multinational corporations (MNCs) by assessing the compatibility between process standardization and corporate structural characteristics in terms of asset configuration...... and headquarters-subsidiary relationships. Design/methodology/approach: First, after a literature review on MNCs’ strategy and process standardization, the study suggests two propositions on the fit between corporate international management strategy and process standardization. Second, to empirically examine....../value: The study provides in-depth understanding of how the international management strategy and consequent structural characteristics of MNCs affects process standardization in the course of a global enterprise resource planning implementation. The study proposes conditions of fit for aligning process...

  15. Determination and validation of soil thresholds for cadmium based on food quality standard and health risk assessment.

    Science.gov (United States)

    Ding, Changfeng; Ma, Yibing; Li, Xiaogang; Zhang, Taolin; Wang, Xingxiang

    2018-04-01

    Cadmium (Cd) is an environmental toxicant with high rates of soil-plant transfer. It is essential to establish an accurate soil threshold for the implementation of soil management practices. This study takes root vegetable as an example to derive soil thresholds for Cd based on the food quality standard as well as health risk assessment using species sensitivity distribution (SSD). A soil type-specific bioconcentration factor (BCF, ratio of Cd concentration in plant to that in soil) generated from soil with a proper Cd concentration gradient was calculated and applied in the derivation of soil thresholds instead of a generic BCF value to minimize the uncertainty. The sensitivity variations of twelve root vegetable cultivars for accumulating soil Cd and the empirical soil-plant transfer model were investigated and developed in greenhouse experiments. After normalization, the hazardous concentrations from the fifth percentile of the distribution based on added Cd (HC5 add ) were calculated from the SSD curves fitted by Burr Type III distribution. The derived soil thresholds were presented as continuous or scenario criteria depending on the combination of soil pH and organic carbon content. The soil thresholds based on food quality standard were on average 0.7-fold of those based on health risk assessment, and were further validated to be reliable using independent data from field survey and published articles. The results suggested that deriving soil thresholds for Cd using SSD method is robust and also applicable to other crops as well as other trace elements that have the potential to cause health risk issues. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Study of system safety evaluation on LTO of national project. Structural integrity assessment of reactor pressure vessels

    International Nuclear Information System (INIS)

    Onizawa, Kunio; Masaki, Koichi; Katsuyama, Jinya; Nishiyama, Yutaka; Osakabe, Kazuya; Nishikawa, Hiroyuki

    2012-01-01

    To assure the structural integrity of a reactor pressure vessel (RPV) is known as one of the critical issues to maintain the safe long-term operation of a nuclear power plant. In Japan, the assessment methods for RPV integrity, stipulated in the codes and standards, have been endorsed by the regulatory body. Authors have initiated extensive research on the improvement of structural integrity assessment methods of RPVs. In this paper, we describe some research results obtained from the first-year activity. These include the study on revisiting the technical background of the methods, such as loading conditions, postulated crack definition, the other evaluation methods. In addition, studies on probabilistic methods for the applicability to the current rules and the standardization of the probabilistic analysis methods have been presented. (author)

  17. [Validity of a standard questionnaire to assess physical activity for specific medical checkups and health guidance].

    Science.gov (United States)

    Kawakami, Ryoko; Miyachi, Motohiko

    2010-10-01

    This study aimed to determine the validity of a standard questionnaire to assess amount of physical activity (PA) and cardiorespiratory fitness (VO2peak). A total of 483 men and women, aged 20 to 69 years, participated. The standard questionnaire included 3 items about exercise, PA, and walking speed. All questions were designed to require an answer of Yes or No. Subjects were classified into one of four groups regarding the number of Yes answers to the three questions, giving activity levels of 0 to 3. The amount of PA was measured objectively with a tn-axial accelerometer which could also calculate daily step counts, and the amounts of PA under 3 metabolic equivalents (METs) and at 3 METs or more. VO2peak. was measured by incremental cycle exercise tests with indirect calorimetry. The daily step counts, the amount of PA at 3 METs or more, and the VO2peak. were significantly higher in subjects who answered Yes to each question than in those who answered No. Sensitivity and specificity of each question were 62-73% and 45-71% for the amount of PA established with the "Exercise and Physical Activity Reference for Health Promotion 2006 (EPAR2006)". The sum of sensitivity and specificity was the highest when the cutoff value was activity level 2 (sensitivity 73%, specificity 68%). Sensitivity and specificity for VO2max established by EPAR2006 were lower than those for the amount of PA. These results suggest that only answering simple questions with a standard questionnaire is sufficient for estimation of PA levels for specific medical checkups and health guidance, even though the accuracy is somewhat limited.

  18. The Definition of Pneumonia, the Assessment of Severity, and Clinical Standardization in the Pneumonia Etiology Research for Child Health Study

    Science.gov (United States)

    Wonodi, Chizoba; Moïsi, Jennifer C.; Deloria-Knoll, Maria; DeLuca, Andrea N.; Karron, Ruth A.; Bhat, Niranjan; Murdoch, David R.; Crawley, Jane; Levine, Orin S.; O’Brien, Katherine L.; Feikin, Daniel R.

    2012-01-01

    To develop a case definition for the Pneumonia Etiology Research for Child Health (PERCH) project, we sought a widely acceptable classification that was linked to existing pneumonia research and focused on very severe cases. We began with the World Health Organization’s classification of severe/very severe pneumonia and refined it through literature reviews and a 2-stage process of expert consultation. PERCH will study hospitalized children, aged 1–59 months, with pneumonia who present with cough or difficulty breathing and have either severe pneumonia (lower chest wall indrawing) or very severe pneumonia (central cyanosis, difficulty breastfeeding/drinking, vomiting everything, convulsions, lethargy, unconsciousness, or head nodding). It will exclude patients with recent hospitalization and children with wheeze whose indrawing resolves after bronchodilator therapy. The PERCH investigators agreed upon standard interpretations of the symptoms and signs. These will be maintained by a clinical standardization monitor who conducts repeated instruction at each site and by recurrent local training and testing. PMID:22403224

  19. Standardization of 8-color flow cytometry across different flow cytometer instruments: A feasibility study in clinical laboratories in Switzerland.

    Science.gov (United States)

    Glier, Hana; Heijnen, Ingmar; Hauwel, Mathieu; Dirks, Jan; Quarroz, Stéphane; Lehmann, Thomas; Rovo, Alicia; Arn, Kornelius; Matthes, Thomas; Hogan, Cassandra; Keller, Peter; Dudkiewicz, Ewa; Stüssi, Georg; Fernandez, Paula

    2017-07-29

    The EuroFlow Consortium developed a fully standardized flow cytometric approach from instrument settings, through antibody panel, reagents and sample preparation protocols, to data acquisition and analysis. The Swiss Cytometry Society (SCS) promoted a study to evaluate the feasibility of using such standardized measurements of 8-color data across two different flow cytometry platforms - Becton Dickinson (BD) FACSCanto II and Beckman Coulter (BC) Navios, aiming at increasing reproducibility and inter-laboratory comparability of immunophenotypic data in clinical laboratories in Switzerland. The study was performed in two phases, i.e. a learning phase (round 1) and an analytical phase (rounds 2 and 3) consisting of a total of three rounds. Overall, 10 laboratories using BD FACSCanto II (n=6) or BC Navios (n=4) flow cytometers participated. Each laboratory measured peripheral blood samples from healthy donors stained with a uniform antibody panel of reagents - EuroFlow Lymphoid Screening Tube (LST) - applying the EuroFlow standardized protocols for instrument setup and sample preparation (www.EuroFlow.org). All data files were analyzed centrally and median fluorescence intensity (MedFI) values for individual markers on defined lymphocyte subsets were recorded; variability from reference MedFI values was assessed using performance scores. Data troubleshooting and discussion of the results with the participants followed after each round at SCS meetings. The results of the learning phase demonstrated that standardized instrument setup and data acquisition are feasible in routine clinical laboratories without previous experience with EuroFlow. During the analytical phase, highly comparable data were obtained at the different laboratories using either BD FACSCanto II or BC Navios. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%. In the last study round, 89% of participants scored over 90% MedFI values within the acceptance criteria

  20. Multivariate approach to assessing ecotoxicity on abandoned oil refinery environments: Study site description

    International Nuclear Information System (INIS)

    Lochmiller, R.L.; Yates, G.W.

    1993-01-01

    Ecology risk assessment requires a clear understanding of how complex mixtures of environmental contaminants impact terrestrial ecosystems. This assessment process could be more universally applied to terrestrial ecosystems with better defined assay systems for evaluating impacts of exposure on organisms, populations, and communities. The authors objective was to define and assess the efficacy of a battery of assays incorporating both standard biological toxicity test and in situ biomonitors for evaluating ecological risks on terrestrial environments contaminated with complex mixtures of petrochemicals on a 160 acre abandoned oil refinery in central Oklahoma. Three suspected contaminated and three uncontaminated reference sites were selected for intensive study. Habitat on each study site is representative of disturbed tall-grass prairie and supports dense, diverse small mammal communities. Soil samples were subjected to aqueous extraction and resulting leachates analyzed for heavy metals, selected ions, and organics. Analytical results support their initial assessment that toxic study sites were contaminated with complex mixtures including lead, zinc, arsenic, chloride, sulfate, potassium, and complex mixtures of polar and non-polar organics

  1. Assessment of three medical and research laboratories using WHO AFRO_SLIPTA Quality Standards in Southwestern Uganda: a long way to go.

    Science.gov (United States)

    Taremwa, Ivan Mugisha; Ampaire, Lucas; Iramiot, Jacob; Muhwezi, Obed; Matte, Aloysius; Itabangi, Herbert; Mbabazi, Hope; Atwebembeire, Jeninah; Kamwine, Monicah; Katawera, Victoria; Mbalibulha, Yona; Orikiriza, Patrick; Boum, Yap

    2017-01-01

    While the laboratory represents more than 70% of clinical diagnosis and patient management, access to reliable and quality laboratory diagnostics in sub-Saharan Africa remains a challenge. To gain knowledge and suggest evidence based interventions towards laboratory improvement in Southwestern Uganda, we assessed the baseline laboratory quality standards in three medical and research laboratories in Southwestern Uganda. We conducted a cross sectional survey from October, 2013 to April, 2014. Selected laboratories, including one private research, one private for profit and one public laboratory, were assessed using the WHO AFRO_SLIPTA checklist and baseline scores were determined. The three laboratories assessed met basic facility requirements, had trained personnel, and safety measures in place. Sample reception was properly designed and executed with a well designated chain of custody. All laboratories had sufficient equipment for the nature of work they were involved in. However, we found that standard operating procedures were incomplete in all three laboratories, lack of quality audit schemes by two laboratories and only one laboratory enrolled into external quality assurance schemes. The SLIPTA scores were one star for the research laboratory and no star for both the public and private-for-profit laboratories. While most of the laboratory systems were in place, the low scores obtained by the assessed laboratories reflect the need for improvement to reach standards of quality assured diagnostics in the region. Therefore, routine mentorship and regional supportive supervision are necessary to increase the quality of laboratory services.

  2. Participation and Performance Reporting for the Alternate Assessment Based on Modified Achievement Standards (AA-MAS). Technical Report 58

    Science.gov (United States)

    Albus, Deb; Thurlow, Martha L.; Lazarus, Sheryl S.

    2011-01-01

    This report examines publicly reported participation and performance data for the alternate assessment based on modified achievement standards (AA-MAS). The authors' analysis of these data included all states publicly reporting AA-MAS data, regardless of whether they had received approval to use the results for Title I accountability calculations.…

  3. Status of characterization techniques for carbon nanotubes and suggestions towards standards suitable for toxicological assessment

    International Nuclear Information System (INIS)

    Schweinberger, Florian F; Meyer-Plath, Asmus

    2011-01-01

    Nanotechnologies promise to contribute significantly to major technological challenges of the upcoming century. Despite profound scientific progress in the last decades, only minor advances have been made in the field of nanomaterial toxicology. The International Team in Nanosafety (TITNT) is an international and multidisciplinary group of scientists, which aims at better understanding the risks of nanomaterials. Carbon nanotubes (CNT) account for one of the most promising nanomaterials and have therefore been chosen as representative material for nanoscaled particles. They are currently investigated by the different platforms of TITNT. As a starting point, the present report summarizes a literature-based study on the physico-chemical properties of CNT, as they are closely linked with toxicological properties. A brief introduction to synthesis, purification and material properties is given. Characterization methods for CNT are discussed with respect to their reliability and the information content on chemical properties. Recommendations for a set of standard characterizations mandatory for toxicological assessment are derived.

  4. Status of characterization techniques for carbon nanotubes and suggestions towards standards suitable for toxicological assessment

    Science.gov (United States)

    Schweinberger, Florian F.; Meyer-Plath, Asmus

    2011-07-01

    Nanotechnologies promise to contribute significantly to major technological challenges of the upcoming century. Despite profound scientific progress in the last decades, only minor advances have been made in the field of nanomaterial toxicology. The International Team in Nanosafety (TITNT) is an international and multidisciplinary group of scientists, which aims at better understanding the risks of nanomaterials. Carbon nanotubes (CNT) account for one of the most promising nanomaterials and have therefore been chosen as representative material for nanoscaled particles. They are currently investigated by the different platforms of TITNT. As a starting point, the present report summarizes a literature-based study on the physico-chemical properties of CNT, as they are closely linked with toxicological properties. A brief introduction to synthesis, purification and material properties is given. Characterization methods for CNT are discussed with respect to their reliability and the information content on chemical properties. Recommendations for a set of standard characterizations mandatory for toxicological assessment are derived.

  5. Status of characterization techniques for carbon nanotubes and suggestions towards standards suitable for toxicological assessment

    Energy Technology Data Exchange (ETDEWEB)

    Schweinberger, Florian F, E-mail: florian.schweinberger@tum.de [International Team in Nanosafety (TITNT) and Technische Universitaet Muenchen, Catalysis Research Center, Chair of Physical Chemistry, Lichtenbergstr. 4, 85748 Garching (Germany); Meyer-Plath, Asmus [International Team in Nanosafety (TITNT) and BAM - Federal Institute for Materials Research and Testing, Division VI.5 - Polymer Surfaces, Unter den Eichen 87, 12205 Berlin (Germany)

    2011-07-06

    Nanotechnologies promise to contribute significantly to major technological challenges of the upcoming century. Despite profound scientific progress in the last decades, only minor advances have been made in the field of nanomaterial toxicology. The International Team in Nanosafety (TITNT) is an international and multidisciplinary group of scientists, which aims at better understanding the risks of nanomaterials. Carbon nanotubes (CNT) account for one of the most promising nanomaterials and have therefore been chosen as representative material for nanoscaled particles. They are currently investigated by the different platforms of TITNT. As a starting point, the present report summarizes a literature-based study on the physico-chemical properties of CNT, as they are closely linked with toxicological properties. A brief introduction to synthesis, purification and material properties is given. Characterization methods for CNT are discussed with respect to their reliability and the information content on chemical properties. Recommendations for a set of standard characterizations mandatory for toxicological assessment are derived.

  6. Development and Psychometric Properties of the Standardized Assessment of Severity of Personality Disorder (SASPD).

    Science.gov (United States)

    Olajide, Kike; Munjiza, Jasna; Moran, Paul; O'Connell, Lesley; Newton-Howes, Giles; Bassett, Paul; Akintomide, Gbolagade; Ng, Nicola; Tyrer, Peter; Mulder, Roger; Crawford, Mike J

    2018-02-01

    Personality disorder (PD) is increasingly categorized according to its severity, but there is no simple way to screen for severity according to ICD-11 criteria. We set out to develop the Standardized Assessment of Severity of Personality Disorder (SASPD). A total of 110 patients completed the SASPD together with a clinical assessment of the severity of personality disorder. We examined the predictive ability of the SASPD using the area under the ROC curve (AUC). Two to four weeks later, 43 patients repeated the SASPD to examine reliability. The SASPD had good predictive ability for determining mild (AUC = 0.86) and moderate (AUC = 0.84) PD at cut points of 8 and 10, respectively. Test-retest reliability of the SASPD was high (intraclass correlation coefficient = 0.93, 95% CI [0.88, 0.96]). The SASPD thus provides a simple, brief, and reliable indicator of the presence of mild or moderate PD according to ICD-11 criteria.

  7. The need for a standard approach to assessing the functionality of rural community water supplies

    Science.gov (United States)

    Bonsor, Helen; MacDonald, Alan; Casey, Vincent; Carter, Richard; Wilson, Paul

    2018-03-01

    The Sustainable Development Goals have set an agenda for transformational change in water access, aiming for secure household connections globally. Despite this goal, communal groundwater supplies are likely to remain the main source of improved water supplies for many rural areas in Africa and South Asia for decades to come. Understanding the poor functionality of existing communal supplies remains, therefore, a priority. A critical first step is to establish a sector-wide definition of borehole supply functionality and a standard method of its assessment.

  8. Impact of a standardized training program on midwives’ ability to assess fetal heart anatomy by ultrasound

    International Nuclear Information System (INIS)

    Hildebrand, Eric; Abrandt Dahlgren, Madeleine; Sved, Catarina; Gottvall, Tomas; Blomberg, Marie; Janerot-Sjoberg, Birgitta

    2014-01-01

    Studies of prenatal detection of congenital heart disease (CHD) in the UK, Italy, and Norway indicate that it should be possible to improve the prenatal detection rate of CHD in Sweden. These studies have shown that training programs, visualization of the outflow tracts and color-Doppler all can help to speed up and improve the detection rate and accuracy. We aimed to introduce a more accurate standardized fetal cardiac ultrasound screening protocol in Sweden. A novel pedagogical model for training midwives in standardized cardiac imaging was developed, a model using a think-aloud analysis during a pre- and post-course test and a subsequent group reflection. The self-estimated difficulties and knowledge gaps of two experienced and two beginner midwives were identified. A two-day course with mixed lectures, demonstrations and hands-on sessions was followed by a feedback session three months later consisting of an interview and check-up. The long-term effects were tested two years later. At the post-course test the self-assessed uncertainty was lower than at the pre-course test. The qualitative evaluation showed that the color Doppler images were difficult to interpret, but the training seems to have improved their ability to use the new technique. The ability to perform the method remained at the new level at follow-up both three months and two years later. Our results indicate that by implementing new imaging modalities and providing hands-on training, uncertainty can be reduced and examination time decreased, but they also show that continuous on-site training with clinical and technical back-up is important

  9. Assessment and Next Generation Standards: An Interview with Olivia Gude

    Science.gov (United States)

    Sweeny, Robert

    2014-01-01

    This article provides a transcript of an interview with Olivia Gude, member of the National Coalition for Core Arts Standards Writing Team. In the interview, Gude provides an overview of the process for writing the new visual arts standards.

  10. Molten Salt Reactor Experiment Facility (Building 7503) standards/requirements identification document adherence assessment plan at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1996-02-01

    This is the Phase 2 (adherence) assessment plan for the Building 7503 Molten Salt Reactor Experiment (MSRE) Facility standards/requirements identification document (S/RID). This document outlines the activities to be conducted from FY 1996 through FY 1998 to ensure that the standards and requirements identified in the MSRE S/RID are being implemented properly. This plan is required in accordance with the Department of Energy Implementation Plan for Defense Nuclear Facilities Safety Board Recommendation 90-2, November 9, 1994, Attachment 1A. This plan addresses the major aspects of the adherence assessment and will be consistent with Energy Systems procedure QA-2. 7 ''Surveillances.''

  11. Validation of the Australian Midwifery Standards Assessment Tool (AMSAT): A tool to assess midwifery competence.

    Science.gov (United States)

    Sweet, Linda; Bazargan, Maryam; McKellar, Lois; Gray, Joanne; Henderson, Amanda

    2018-02-01

    There is no current validated clinical assessment tool to measure the attainment of midwifery student competence in the midwifery practice setting. The lack of a valid assessment tool has led to a proliferation of tools and inconsistency in assessment of, and feedback on student learning. This research aimed to develop and validate a tool to assess competence of midwifery students in practice-based settings. A mixed-methods approach was used and the study implemented in two phases. Phase one involved the development of the AMSAT tool with qualitative feedback from midwifery academics, midwife assessors of students, and midwifery students. In phase two the newly developed AMSAT tool was piloted across a range of midwifery practice settings and ANOVA was used to compare scores across year levels, with feedback being obtained from assessors. Analysis of 150 AMSAT forms indicate the AMSAT as: reliable (Cronbach alpha greater than 0.9); valid-data extraction loaded predominantly onto one factor; and sensitivity scores indicating level of proficiency increased across the three years. Feedback evaluation forms (n=83) suggest acceptance of this tool for the purpose of both assessing and providing feedback on midwifery student's practice performance and competence. The AMSAT is a valid, reliable and acceptable midwifery assessment tool enables consistent assessment of midwifery student competence. This assists benchmarking across midwifery education programs. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  12. JPL Thermal Design Modeling Philosophy and NASA-STD-7009 Standard for Models and Simulations - A Case Study

    Science.gov (United States)

    Avila, Arturo

    2011-01-01

    The Standard JPL thermal engineering practice prescribes worst-case methodologies for design. In this process, environmental and key uncertain thermal parameters (e.g., thermal blanket performance, interface conductance, optical properties) are stacked in a worst case fashion to yield the most hot- or cold-biased temperature. Thus, these simulations would represent the upper and lower bounds. This, effectively, represents JPL thermal design margin philosophy. Uncertainty in the margins and the absolute temperatures is usually estimated by sensitivity analyses and/or by comparing the worst-case results with "expected" results. Applicability of the analytical model for specific design purposes along with any temperature requirement violations are documented in peer and project design review material. In 2008, NASA released NASA-STD-7009, Standard for Models and Simulations. The scope of this standard covers the development and maintenance of models, the operation of simulations, the analysis of the results, training, recommended practices, the assessment of the Modeling and Simulation (M&S) credibility, and the reporting of the M&S results. The Mars Exploration Rover (MER) project thermal control system M&S activity was chosen as a case study determining whether JPL practice is in line with the standard and to identify areas of non-compliance. This paper summarizes the results and makes recommendations regarding the application of this standard to JPL thermal M&S practices.

  13. An Open Standard for Camera Trap Data

    Directory of Open Access Journals (Sweden)

    Tavis Forrester

    2016-12-01

    Full Text Available Camera traps that capture photos of animals are a valuable tool for monitoring biodiversity. The use of camera traps is rapidly increasing and there is an urgent need for standardization to facilitate data management, reporting and data sharing. Here we offer the Camera Trap Metadata Standard as an open data standard for storing and sharing camera trap data, developed by experts from a variety of organizations. The standard captures information necessary to share data between projects and offers a foundation for collecting the more detailed data needed for advanced analysis. The data standard captures information about study design, the type of camera used, and the location and species names for all detections in a standardized way. This information is critical for accurately assessing results from individual camera trapping projects and for combining data from multiple studies for meta-analysis. This data standard is an important step in aligning camera trapping surveys with best practices in data-intensive science. Ecology is moving rapidly into the realm of big data, and central data repositories are becoming a critical tool and are emerging for camera trap data. This data standard will help researchers standardize data terms, align past data to new repositories, and provide a framework for utilizing data across repositories and research projects to advance animal ecology and conservation.

  14. Study on the testing standards of quality assurance for CT image

    International Nuclear Information System (INIS)

    Liu Jingxin; Yang Haishan; Liu Gang; Wang Liyun

    2000-01-01

    Objective: To establish national testing standards of quality assurance for CT image. Methods: 104 sets of CT system were tested using quality assurance test phantoms and devices including American RMI 461A, RMI 463, MDH 1015 C with ION Chamber, Sweden UNF 9004 kvp meter. These CT were made from different manufacturers including out of date of CT and state-of-art spiral CT system. Thirteen kinds of standards on CT from different countries and 87 sets of technical specifications of CT were collected. The results of the test were compared using phantoms of RMI, Victoreen, Catphan on the same CT system (Siemens HQS). Results: Based on the test results of this study, with reference to the foreign standards and some of regulations in China, CT test items should include high contrast resolution, low contrast resolution, noise, uniformity, mean CT unit, dose slice thickness, localization light, positioning of patient support and gantry tilt. Standards including acceptance test, status test, and constancy test were made in specification. Among them, constancy test equals to IEC 122-2-6; items and results in acceptance test are stricter than in the status test; and low contrast resolution, uniformity, localization light accuracy and positioning of patient support in the acceptance test are even stricter than that in foreign standards. Conclusion: The testing standards of quality assurance for CT developed in this study shows practical and useful in China, which supplemented to the existing international standards

  15. From Standards to Standard Practice: A Critical Look at the Perceptions and Process of Integrating the Next Generation Science Standards in the Nation's Schools

    Science.gov (United States)

    Mercadante, Katie Lynn

    The Next Generation Science Standards (NGSS) are the culmination of reform efforts spanning more than three decades and are the first major reform movement in science education since Sputnik. When implementing these new standards, teachers are faced with many barriers. NGSS requires critical thinking, cross-curricular learning, and key changes in teaching, learning, and assessment. Implementation nationwide has been slow, due to sweeping changes, and controversial content within the standards. Resistance to implementation occurs in nearly all levels for these reasons. The purpose of this descriptive study was to determine the perceptions of in-service teachers of the NGSS Framework, to identify barriers that inhibit implementation, and to identify commonalities among teachers who have successfully implemented the Framework, as well as assist others who may do the same in the future. Teachers from public, private, and charter schools from across the United States participated in the study. Based upon teacher response, a three-stage action plan and series of necessary recommendations were developed to assist teachers and administrators in K-12 schools to develop plans to implement the NGSS.

  16. Assessing ventricular size: is subjective evaluation accurate enough? New MRI-based normative standards for 19-year-olds

    Energy Technology Data Exchange (ETDEWEB)

    Aukland, Stein Magnus [Haukeland University Hospital, Department of Radiology, Bergen (Norway); University of Bergen, Institute of Surgical Sciences, Section for Radiology, Bergen (Norway); Odberg, Morten Duus [University of Bergen, Institute of Clinical Medicine, Section for Paediatrics, Bergen (Norway); Gunny, Roxanna; Chong, W.K. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Eide, Geir Egil [Haukeland University Hospital, Centre for Clinical Research, Bergen (Norway); University of Bergen, Department of Public Health and Primary Health Care, Bergen (Norway); Rosendahl, Karen [University of Bergen, Institute of Surgical Sciences, Section for Radiology, Bergen (Norway); Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom)

    2008-12-15

    To create new standards for radiological indices of dilated ventricles and to compare these with subjectively assessed ventricular size. One hundred healthy controls (54 females), birth weight above 3,000 g, were followed throughout childhood as part of a longitudinal study of ex-prematures. All had a 3 Tesla brain magnetic resonance scan at age 17-20, and the following measurements were performed: biparietal and occipitofrontal diameters, width and depth of the frontal and occipital horns, diameter of the third ventricle and the frontal sub-arachnoid space. Ventricular size was judged subjectively by two neuroradiologists as being normal, or mildly, moderately or severely dilated. Head circumference was 31 mm higher for males than for females (95% confidence interval (CI) 25-28, p < 0.001). Similar, ventricular size except for the depth of the right frontal horn was larger for male; however, the observed differences were partly accounted for by the larger head circumference. Normative sex specific standards for different cerebral measurements were presented as mean and ranges and additional 2.5, 10, 50, 90, 97.5 percentiles. The mean depth of the left ventricle was larger than the right for males, with an observed difference of 0.6 mm in male (95% CI 0.2-0.9, p = 0.005). The mean width of the left ventricle was larger than the right for females, with an observed difference of 0.4 mm in male (95% CI 0.1-0.7, p = 0.018). Two subjects were judged to have moderately and 36 to have mildly dilated ventricles by observer one, while figures for observer two were one and 14. Overall, the two observers agreed on 15 having either mild or moderate dilatation (kappa 0.43). For both sexes, the mean depth of the frontal horns as well as of the larger occipital horns differed significantly between the no dilatation and the mild/moderate dilatation groups. In our unselected cohort of healthy 19-year-olds, a high total of 14% was diagnosed to have dilated cerebral ventricles when

  17. Assessing ventricular size: is subjective evaluation accurate enough? New MRI-based normative standards for 19-year-olds

    International Nuclear Information System (INIS)

    Aukland, Stein Magnus; Odberg, Morten Duus; Gunny, Roxanna; Chong, W.K.; Eide, Geir Egil; Rosendahl, Karen

    2008-01-01

    To create new standards for radiological indices of dilated ventricles and to compare these with subjectively assessed ventricular size. One hundred healthy controls (54 females), birth weight above 3,000 g, were followed throughout childhood as part of a longitudinal study of ex-prematures. All had a 3 Tesla brain magnetic resonance scan at age 17-20, and the following measurements were performed: biparietal and occipitofrontal diameters, width and depth of the frontal and occipital horns, diameter of the third ventricle and the frontal sub-arachnoid space. Ventricular size was judged subjectively by two neuroradiologists as being normal, or mildly, moderately or severely dilated. Head circumference was 31 mm higher for males than for females (95% confidence interval (CI) 25-28, p < 0.001). Similar, ventricular size except for the depth of the right frontal horn was larger for male; however, the observed differences were partly accounted for by the larger head circumference. Normative sex specific standards for different cerebral measurements were presented as mean and ranges and additional 2.5, 10, 50, 90, 97.5 percentiles. The mean depth of the left ventricle was larger than the right for males, with an observed difference of 0.6 mm in male (95% CI 0.2-0.9, p = 0.005). The mean width of the left ventricle was larger than the right for females, with an observed difference of 0.4 mm in male (95% CI 0.1-0.7, p = 0.018). Two subjects were judged to have moderately and 36 to have mildly dilated ventricles by observer one, while figures for observer two were one and 14. Overall, the two observers agreed on 15 having either mild or moderate dilatation (kappa 0.43). For both sexes, the mean depth of the frontal horns as well as of the larger occipital horns differed significantly between the no dilatation and the mild/moderate dilatation groups. In our unselected cohort of healthy 19-year-olds, a high total of 14% was diagnosed to have dilated cerebral ventricles when

  18. Next Generation Science Standards: Considerations for Curricula, Assessments, Preparation, and Implementation

    Science.gov (United States)

    Best, Jane; Dunlap, Allison

    2014-01-01

    This policy brief provides an overview of the Next Generation Science Standards (NGSS), discusses policy considerations for adopting or adapting the new standards, and presents examples from states considering or implementing the NGSS. Changing academic standards is a complex process that requires significant investments of time, money, and human…

  19. Fulfillment of GMP standard, halal standard, and applying HACCP for production process of beef floss (Case study: Ksatria enterprise)

    Science.gov (United States)

    A'diat, Arkan Addien Al; Liquiddanu, Eko; Laksono, Pringgo Widyo; Sutopo, Wahyudi; Suletra, I. Wayan

    2018-02-01

    Along with the increasing number of the modern retail business in Indonesia, give an opportunity to small and medium enterprise (SME) to sell its products through the modern retailer. There are some obstacles faced by the SMEs, one of them is about product standard. Product standard that must be owned by SMEs are GMP standard and halal standard. This research was conducted to know the fulfillment by the beef floss enterprise in jagalan in fulfilling the GMP standard and halal. In addition, Hazard Analysis and Critical Control Points (HACCP) system was applied to analyze the process. HACCP which used in this research was based on the seven principles in SNI (Indonesian National Standard) 01-4852-1998. The seven principles included hazard analysis, critical control point (CCP) determination, critical limit establishment, CCP monitor system establishment, corrective action establishment, verification, and also documentation establishment that must be applied in preparing HACCP plan. Based on this case study, it is concluded that there were 5 CCPs : the boiling process, roasting process, frying process, the beef floss draining process, and the packaging process.

  20. Standard Procedure for Dose Assessment using the film holder NRPB/AERE and the film AGFA Monitoring 2/10

    International Nuclear Information System (INIS)

    Guillen, J.A.

    1998-07-01

    This paper describes the calculation method to assess dose and energy using the film holder from NRPB/AERE and the film Agfa Monitoring 2/10. Also includes all the steps since preparing the standard curve, fitting of calibration curve, dose assesment, description of filtration of the film holder and the form of the calibration curve

  1. Setting technical standards for visual assessment procedures

    Science.gov (United States)

    Kenneth H. Craik; Nickolaus R. Feimer

    1979-01-01

    Under the impetus of recent legislative and administrative mandates concerning analysis and management of the landscape, governmental agencies are being called upon to adopt or develop visual resource and impact assessment (VRIA) systems. A variety of techniques that combine methods of psychological assessment and landscape analysis to serve these purposes is being...

  2. Pilot randomized crossover study comparing the efficacy of transnasal disposable endosheath with standard endoscopy to detect Barrett's esophagus.

    Science.gov (United States)

    Shariff, Mohammed K; Varghese, Sibu; O'Donovan, Maria; Abdullahi, Zarah; Liu, Xinxue; Fitzgerald, Rebecca C; di Pietro, Massimiliano

    2016-02-01

    The transnasal endosheath endoscope is a new disposable technology with potential applicability to the primary care setting. The aim of this study was to evaluate the efficacy of transnasal endosheath endoscopy (TEE) for the detection of Barrett's esophagus, by comparing the diagnostic accuracy of TEE with that of standard endoscopy. This was a prospective, randomized, crossover study performed in a single tertiary referral center. Consecutive patients undergoing surveillance for Barrett's esophagus or referred for diagnostic assessment were recruited. All patients were randomized to undergo TEE followed by standard endoscopy or the reverse. Endoscopy experiences and patient preferences were evaluated using a questionnaire. Endoscopic and histologic diagnosis of Barrett's esophagus, and optical image quality of both endoscopic procedures, were compared. A total of 21 of 25 patients completed the study. TEE had sensitivity and specificity of 100 % for an endoscopic diagnosis of Barrett's esophagus, and of 66.7 % and 100 %, respectively, for the histologic diagnosis of Barrett's esophagus. The mean optical quality of standard endoscopy was significantly better than that of TEE (7.11 ± 0.42 vs. 4.06 ± 0.27; P evaluation in primary care as an initial diagnostic tool. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Technical support document: Energy efficiency standards for consumer products: Refrigerators, refrigerator-freezers, and freezers including draft environmental assessment, regulatory impact analysis

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Energy Policy and Conservation Act (P.L. 94-163), as amended by the National Appliance Energy Conservation Act of 1987 (P.L. 100-12) and by the National Appliance Energy Conservation Amendments of 1988 (P.L. 100-357), and by the Energy Policy Act of 1992 (P.L. 102-486), provides energy conservation standards for 12 of the 13 types of consumer products` covered by the Act, and authorizes the Secretary of Energy to prescribe amended or new energy standards for each type (or class) of covered product. The assessment of the proposed standards for refrigerators, refrigerator-freezers, and freezers presented in this document is designed to evaluate their economic impacts according to the criteria in the Act. It includes an engineering analysis of the cost and performance of design options to improve the efficiency of the products; forecasts of the number and average efficiency of products sold, the amount of energy the products will consume, and their prices and operating expenses; a determination of change in investment, revenues, and costs to manufacturers of the products; a calculation of the costs and benefits to consumers, electric utilities, and the nation as a whole; and an assessment of the environmental impacts of the proposed standards.

  4. A review of multidisciplinary clinical practice guidelines in suicide prevention: toward an emerging standard in suicide risk assessment and management, training and practice.

    Science.gov (United States)

    Bernert, Rebecca A; Hom, Melanie A; Roberts, Laura Weiss

    2014-10-01

    The current paper aims to: (1) examine clinical practice guidelines in suicide prevention across fields, organizations, and clinical specialties and (2) inform emerging standards in clinical practice, research, and training. The authors conducted a systematic literature review to identify clinical practice guidelines and resource documents in suicide prevention and risk management. The authors used PubMed, Google Scholar, and Google Search, and keywords included: clinical practice guideline, practice guideline, practice parameters, suicide, suicidality, suicidal behaviors, assessment, and management. To assess for commonalities, the authors reviewed guidelines and resource documents across 13 key content categories and assessed whether each document suggested validated assessment measures. The search generated 101 source documents, which included N = 10 clinical practice guidelines and N = 12 additional resource documents (e.g., non-formalized guidelines, tool-kits). All guidelines (100 %) provided detailed recommendations for the use of evidence-based risk factors and protective factors, 80 % provided brief (but not detailed) recommendations for the assessment of suicidal intent, and 70 % recommended risk management strategies. By comparison, only 30 % discussed standardization of risk-level categorizations and other content areas considered central to best practices in suicide prevention (e.g., restricting access to means, ethical considerations, confidentiality/legal issues, training, and postvention practices). Resource documents were largely consistent with these findings. Current guidelines address similar aspects of suicide risk assessment and management, but significant discrepancies exist. A lack of consensus was evident in recommendations across core competencies, which may be improved by increased standardization in practice and training. Additional resources appear useful for supplemental use.

  5. Montreal Cognitive Assessment Is Superior to Standardized Mini-Mental Status Exam in Detecting Mild Cognitive Impairment in the Middle-Aged and Elderly Patients with Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Kannayiram Alagiakrishnan

    2013-01-01

    Full Text Available Aim. This study compares the usefulness of Montreal Cognitive Assessment (MoCA to Standardized Mini-Mental Status Exam (SMMSE for diagnosing mild cognitive impairment (MCI in Type 2 diabetes mellitus (DM population. Methods. This prospective pilot study enrolled 30 community dwelling adults with Type 2 DM aged 50 years and above. Subjects were assessed using both the SMMSE and MoCA for MCI. In all subjects, depression and dementia were ruled out using the DSM IV criteria, and a functional assessment was done. MCI was diagnosed using the standard test, the European consortium criteria. Sensitivity and specificity analysis, positive and negative predictive values, likelihood ratios and Kappa statistic were calculated. Results. In comparison to consortium criteria, the sensitivity and specificity of MoCA were 67% and 93% in identifying individuals with MCI, and SMMSE were 13% and 93%, respectively. The positive and negative predictive values for MoCA were 84% and 56%, and for SMMSE were 66% and 51%, respectively. Kappa statistics showed moderate agreement between MoCA and consortium criteria (kappa = 0.4 and a low agreement between SMMSE and consortium criteria (kappa = 0.07. Conclusion. In this pilot study, MoCA appears to be a better screening tool than SMMSE for MCI in the diabetic population.

  6. Development of A Standard Method for Human Reliability Analysis of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Jung, Won Dea; Kang, Dae Il; Kim, Jae Whan

    2005-12-01

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method

  7. Development of A Standard Method for Human Reliability Analysis of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Won Dea; Kang, Dae Il; Kim, Jae Whan

    2005-12-15

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method.

  8. Standardization and optimization of fluorescence in situ hybridization (FISH for HER-2 assessment in breast cancer: A single center experience

    Directory of Open Access Journals (Sweden)

    Magdalena Bogdanovska-Todorovska

    2018-05-01

    Full Text Available Accurate assessment of human epidermal growth factor receptor 2 (HER-2 is crucial in selecting patients for targeted therapy. Commonly used methods for HER-2 testing are immunohistochemistry (IHC and fluorescence in situ hybridization (FISH. Here we presented the implementation, optimization and standardization of two FISH protocols using breast cancer samples and assessed the impact of pre-analytical and analytical factors on HER-2 testing. Formalin fixed paraffin embedded (FFPE tissue samples from 70 breast cancer patients were tested for HER-2 using PathVysion™ HER-2 DNA Probe Kit and two different paraffin pretreatment kits, Vysis/Abbott Paraffin Pretreatment Reagent Kit (40 samples and DAKO Histology FISH Accessory Kit (30 samples. The concordance between FISH and IHC results was determined. Pre-analytical and analytical factors (i.e., fixation, baking, digestion, and post-hybridization washing affected the efficiency and quality of hybridization. The overall hybridization success in our study was 98.6% (69/70; the failure rate was 1.4%. The DAKO pretreatment kit was more time-efficient and resulted in more uniform signals that were easier to interpret, compared to the Vysis/Abbott kit. The overall concordance between IHC and FISH was 84.06%, kappa coefficient 0.5976 (p < 0.0001. The greatest discordance (82% between IHC and FISH was observed in IHC 2+ group. A standardized FISH protocol for HER-2 assessment, with high hybridization efficiency, is necessary due to variability in tissue processing and individual tissue characteristics. Differences in the pre-analytical and analytical steps can affect the hybridization quality and efficiency. The use of DAKO pretreatment kit is time-saving and cost-effective.

  9. The Interpretation of "in Context" Verbal Probability Expressions Used in International Accounting Standards: A Comparison of English and Chinese Students Studying at English Speaking Universities

    Science.gov (United States)

    Salleh, Safrul Izani Mohd; Gardner, John C.; Sulong, Zunaidah; McGowan, Carl B., Jr.

    2011-01-01

    This study examines the differences in the interpretation of ten "in context" verbal probability expressions used in accounting standards between native Chinese speaking and native English speaking accounting students in United Kingdom universities. The study assesses the degree of grouping factors consensus on the numerical…

  10. A Comparison between Standard and Functional Clustering Methodologies: Application to Agricultural Fields for Yield Pattern Assessment

    Directory of Open Access Journals (Sweden)

    Simone Pascucci

    2018-04-01

    Full Text Available The recognition of spatial patterns within agricultural fields, presenting similar yield potential areas, stable through time, is very important for optimizing agricultural practices. This study proposes the evaluation of different clustering methodologies applied to multispectral satellite time series for retrieving temporally stable (constant patterns in agricultural fields, related to within-field yield spatial distribution. The ability of different clustering procedures for the recognition and mapping of constant patterns in fields of cereal crops was assessed. Crop vigor patterns, considered to be related to soils characteristics, and possibly indicative of yield potential, were derived by applying the different clustering algorithms to time series of Landsat images acquired on 94 agricultural fields near Rome (Italy. Two different approaches were applied and validated using Landsat 7 and 8 archived imagery. The first approach automatically extracts and calculates for each field of interest (FOI the Normalized Difference Vegetation Index (NDVI, then exploits the standard K-means clustering algorithm to derive constant patterns at the field level. The second approach applies novel clustering procedures directly to spectral reflectance time series, in particular: (1 standard K-means; (2 functional K-means; (3 multivariate functional principal components clustering analysis; (4 hierarchical clustering. The different approaches were validated through cluster accuracy estimates on a reference set of FOIs for which yield maps were available for some years. Results show that multivariate functional principal components clustering, with an a priori determination of the optimal number of classes for each FOI, provides a better accuracy than those of standard clustering algorithms. The proposed novel functional clustering methodologies are effective and efficient for constant pattern retrieval and can be used for a sustainable management of

  11. Standardization for Ki-67 Assessment in Moderately Differentiated Breast Cancer. A Retrospective Analysis of the SAKK 28/12 Study

    Science.gov (United States)

    Varga, Zsuzsanna; Cassoly, Estelle; Li, Qiyu; Oehlschlegel, Christian; Tapia, Coya; Lehr, Hans Anton; Klingbiel, Dirk; Thürlimann, Beat; Ruhstaller, Thomas

    2015-01-01

    Background Proliferative activity (Ki-67 Labelling Index) in breast cancer increasingly serves as an additional tool in the decision for or against adjuvant chemotherapy in midrange hormone receptor positive breast cancer. Ki-67 Index has been previously shown to suffer from high inter-observer variability especially in midrange (G2) breast carcinomas. In this study we conducted a systematic approach using different Ki-67 assessments on large tissue sections in order to identify the method with the highest reliability and the lowest variability. Materials and Methods Five breast pathologists retrospectively analyzed proliferative activity of 50 G2 invasive breast carcinomas using large tissue sections by assessing Ki-67 immunohistochemistry. Ki-67-assessments were done on light microscopy and on digital images following these methods: 1) assessing five regions, 2) assessing only darkly stained nuclei and 3) considering only condensed proliferative areas (‘hotspots’). An individual review (the first described assessment from 2008) was also performed. The assessments on light microscopy were done by estimating. All measurements were performed three times. Inter-observer and intra-observer reliabilities were calculated using the approach proposed by Eliasziw et al. Clinical cutoffs (14% and 20%) were tested using Fleiss’ Kappa. Results There was a good intra-observer reliability in 5 of 7 methods (ICC: 0.76–0.89). The two highest inter-observer reliability was fair to moderate (ICC: 0.71 and 0.74) in 2 methods (region-analysis and individual-review) on light microscopy. Fleiss’-kappa-values (14% cut-off) were the highest (moderate) using the original recommendation on light-microscope (Kappa 0.58). Fleiss’ kappa values (20% cut-off) were the highest (Kappa 0.48 each) in analyzing hotspots on light-microscopy and digital-analysis. No methodologies using digital-analysis were superior to the methods on light microscope. Conclusion Our results show that all

  12. Ecotoxicological hazard assessment of hydrocarbon contaminated soils: A case study

    International Nuclear Information System (INIS)

    Roy, Y.; Pauwels, S.J.; Chasse, R.

    1994-01-01

    The Ecotoxicological Hazard Assessment (EHA) developed by the Quebec Ministry of Environment and Wildlife was used as part of the management scheme of contaminated soils from a former refinery. The study consists of assessing five types of soils (reference, heavily contaminated, slightly contaminated, thermally-treated, and biotreated) to determine their relative intrinsic hazard. During the exploratory activities a series of ten assessment endpoints where identified to support this typical EHA. During SOURCE characterization, the physicochemical make-up of the soils is described and the presence and concentrations of priority pollutants is determined. During FATE characterization, the potential for bioconcentration, mobility, and persistence of pollutants is determined. During EFFECTS characterization, the soils and their leachates are tested using standard terrestrial and aquatic bioassays. The data from the toxicological and analytical testing program are evaluated semi-quantitatively on the basis of a scoring system developed by consensus. The discussion will highlight how data are used within an EHA to streamline the decision-making process regarding the follow-up cleanup and disposal of contaminated soils

  13. Data-protection standards and confidentiality of HIV/AIDS status in the workplace - a South African case study.

    Science.gov (United States)

    Muskat-Gorska, Zuzanna

    2008-11-01

    The article contextualises an emerging new regime for information privacy in South Africa (i.e. the draft Protection of Personal Information Bill). Subsequently, it discusses the possibility of successful implementation of international data-protection standards in an environment where there is an urgent need to balance HIV/AIDS confidentiality rights with public health requirements. Also, the article presents a preliminary assessment of the possible impact of professionalisation (and outsourcing) of workplace HIV/AIDS management on workplace data-protection practices, and it identifies some spaces for social dialogue on HIV/AIDS-data treatment in South Africa. The study methods comprise an analysis of legal documents (concerning international data-protection standards and the development of law governing data protection and HIV/AIDS confidentiality in South Africa) and interviews conducted with workplace health managers and trade union representatives, in Johannesburg, in 2007.

  14. Business performance assessment and the EFQM Excellence Model 2010 (case study

    Directory of Open Access Journals (Sweden)

    Mária Antošová

    2015-01-01

    Full Text Available The application of the latest management methods becomes today, during the ongoing European integration processes, a requisite for the success of the business within the environment of international markets. In this paper, the authors pay attention to the expansion of the organizational knowledge base with an application of a new management method. They are dealing with assessment of the organization performance, the issue of its effectiveness and the increasing economic efficiency, on an example of a selected mining company as a case study. In order to detect weaknesses in the company reviewed and to offer suggestions for improvement, which may move the company towards prosperity, the authors carried out the performance assessment by using the EFQM Excellence Model 2010. The aim of this paper is to introduce the business performance assessment model in terms of the European standards that will allow the use of latest management methods in the environment of both the Slovak and European companies.

  15. [Study on standardization of cupping technique: elucidation on the establishment of the National Standard Standardized Manipulation of Acupuncture and Moxibustion, Part V, Cupping].

    Science.gov (United States)

    Gao, Shu-zhong; Liu, Bing

    2010-02-01

    From the aspects of basis, technique descriptions, core contents, problems and solutions, and standard thinking in standard setting process, this paper states experiences in the establishment of the national standard Standardized Manipulation of Acupuncture and Moxibustion, Part V, Cupping, focusing on methodologies used in cupping standard setting process, the method selection and operating instructions of cupping standardization, and the characteristics of standard TCM. In addition, this paper states the scope of application, and precautions for this cupping standardization. This paper also explaines tentative ideas on the research of standardized manipulation of acupuncture and moxibustion.

  16. HCPB TBM thermo mechanical design: Assessment with respect codes and standards and DEMO relevancy

    International Nuclear Information System (INIS)

    Cismondi, F.; Kecskes, S.; Aiello, G.

    2011-01-01

    In the frame of the activities of the European TBM Consortium of Associates the Helium Cooled Pebble Bed Test Blanket Module (HCPB-TBM) is developed in Karlsruhe Institute of Technology (KIT). After performing detailed thermal and fluid dynamic analyses of the preliminary HCPB TBM design, the thermo mechanical behaviour of the TBM under typical ITER loads has to be assessed. A synthesis of the different design options proposed has been realized building two different assemblies of the HCPB-TBM: these two assemblies and the analyses performed on them are presented in this paper. Finite Element thermo-mechanical analyses of two detailed 1/4 scaled models of the HCPB-TBM assemblies proposed have been performed, with the aim of verifying the accordance of the mechanical behaviour with the criteria of the design codes and standards. The structural design limits specified in the codes and standard are discussed in relation with the EUROFER available data and possible damage modes. Solutions to improve the weak structural points of the present design are identified and the DEMO relevancy of the present thermal and structural design parameters is discussed.

  17. Standard-Setting Methods as Measurement Processes

    Science.gov (United States)

    Nichols, Paul; Twing, Jon; Mueller, Canda D.; O'Malley, Kimberly

    2010-01-01

    Some writers in the measurement literature have been skeptical of the meaningfulness of achievement standards and described the standard-setting process as blatantly arbitrary. We argue that standard setting is more appropriately conceived of as a measurement process similar to student assessment. The construct being measured is the panelists'…

  18. Assessment of organ doses by standard X-ray procedures in the GDR

    International Nuclear Information System (INIS)

    Tautz, M.; Brandt, G.A.

    1986-01-01

    A modern method has been described to assess the radiation burden by X-ray procedures with consideration of the standards of our Society for Medical Radiology in the GDR. The underlying methodology is a Monte Carlo computer technique, which simulates stochastically the energy deposition of X-ray photons in a mathematically described heterogeneous anthropomorphic phantom by Rosenstein (US Department of Health, Education and Welfare). To apply the procedure specific values for the following parameters must be determined for each dose estimation: projection and view, X-ray field size and location entrance exposure at skin surface, beam quality, source-to-image receptor distance. The base data are obtained in terms of tissue-air ratio. Organ doses were calculated for chest, urography, skull, cervical spine, thoracic spine, lumbar spine, pelvis and lymphography. Concluding possibilities have been discussed for reduction of radiation burden. 9 refs., 6 figs., 9 tabs. (author)

  19. 29 CFR 1607.5 - General standards for validity studies.

    Science.gov (United States)

    2010-07-01

    ...) (hereinafter “A.P.A. Standards”) and standard textbooks and journals in the field of personnel selection. D... market and the job should be considered in the determination of when a validity study is outdated. ...

  20. Defining new standards on citizen participation in the Chilean environmental assessment

    Directory of Open Access Journals (Sweden)

    Pilar Moraga Sariego

    2017-06-01

    Full Text Available The Law 19,300 on the General Bases of the Environment (1994 provided the first legal framework for environmental protection in the country, in the context of the Rio Summit held two years earlier. Following the recommendations of OECD to strengthen environmental institutions (2005, the legislator passed Law No. 20,417 introducing environmental reform (2010 and Law No. 20,600 creating the Environmental Tribunals (2012. The first one extends the scope of citizen participation in the environmental impact assessment system, however, it is the jurisprudential work of the Second Environmental Court that will make it possible to understand the real scope of the legislative amendment. This specialized judiciary develops new standards of citizen participation in the framework of the project of the State Railway Company. This is a broad interpretation of the principle with a view to a real and not only formal application of it, which contributes to the strengthening of this institution in relation to the principle of access to information and justice in environmental matters.

  1. Dimethylthioarsinic anhydride: A standard for arsenic speciation

    International Nuclear Information System (INIS)

    Fricke, Michael; Zeller, Matthias; Cullen, William; Witkowski, Mark; Creed, John

    2007-01-01

    Dimethylthioarsinic acid (DMTA V ) has recently been identified in biological, dietary and environmental matrices. The relevance of this compound to the toxicity of arsenic in humans is unknown and further exposure assessment and metabolic studies are difficult to conduct because of the unavailability of a well characterized standard. The synthesis of DMTA V was accomplished by the reaction of dimethylarsinic acid (DMA V ) with hydrogen sulfide. The initial reaction product produced is DMTA V but multiple products over the course of the reaction are also observed. Therefore, a chromatographic separation was developed to monitor the reaction progress via LC-ICP-MS. In this synthesis, conversion of DMA V to DMTA V was not taken to completion to avoid the production of side products. The product was isolated from the starting material by standard organic techniques. Single crystal diffraction demonstrated that solid DMTA V is present in the form of the oxygen-bridged dimethylthioarsinic anhydride. Dissolution of the anhydride in water produces the acid form of DMTA V and the aqueous phase DMTA V provided a characteristic molecular ion of m/z 155 by LC-ESI-MS. The synthesis and isolation of dimethylthioarsinic anhydride provides a stable crystalline standard suitable for identification, toxicological study and exposure assessment of dimethylthioarsinic acid

  2. Tying Together the Common Core of Standards, Instruction, and Assessments

    Science.gov (United States)

    Phillips, Vicki; Wong, Carina

    2010-01-01

    Clear, high standards will enable us to develop an education system that ensures that high school graduates are ready for college. The Bill & Melinda Gates Foundation has been working with other organizations to develop a Common Core of Standards. The partners working with the foundation are developing tools that will show teachers what is…

  3. Standards Performance Continuum: Development and Validation of a Measure of Effective Pedagogy.

    Science.gov (United States)

    Doherty, R. William; Hilberg, R. Soleste; Epaloose, Georgia; Tharp, Roland G.

    2002-01-01

    Describes the development and validation of the Standards Performance Continuum (SPC) for assessing teacher performance of the Standards for Effective Pedagogy. Three studies involving Florida, California, and New Mexico public school teachers provided evidence of inter-rater reliability, concurrent validity, and criterion-related validity…

  4. Fulfilling a Promise: Standards for Technological Literacy.

    Science.gov (United States)

    Bybee, Rodger W.

    2003-01-01

    Discusses the place of standards in U.S. education, the development of the Standards for Technological Literacy, and the recent publication of "Advancing Excellence in Technological Literacy: Student Assessment, Professional Development, and Program Standards." (Contains 21 references.) (SK)

  5. A standardized tritrophic small-scale system (TriCosm) for the assessment of stressor-induced effects on aquatic community dynamics.

    Science.gov (United States)

    Riedl, Verena; Agatz, Annika; Benstead, Rachel; Ashauer, Roman

    2018-04-01

    Chemical impacts on the environment are routinely assessed in single-species tests. They are employed to measure direct effects on nontarget organisms, but indirect effects on ecological interactions can only be detected in multispecies tests. Micro- and mesocosms are more complex and environmentally realistic, yet they are less frequently used for environmental risk assessment because resource demand is high, whereas repeatability and statistical power are often low. Test systems fulfilling regulatory needs (i.e., standardization, repeatability, and replication) and the assessment of impacts on species interactions and indirect effects are lacking. In the present study we describe the development of the TriCosm, a repeatable aquatic multispecies test with 3 trophic levels and increased statistical power. High repeatability of community dynamics of 3 interacting aquatic populations (algae, Ceriodaphnia, and Hydra) was found with an average coefficient of variation of 19.5% and the ability to determine small effect sizes. The TriCosm combines benefits of both single-species tests (fulfillment of regulatory requirements) and complex multispecies tests (ecological relevance) and can be used, for instance, at an intermediate tier in environmental risk assessment. Furthermore, comparatively quickly generated population and community toxicity data can be useful for the development and testing of mechanistic effect models. Environ Toxicol Chem 2018;37:1051-1060. © 2017 SETAC. © 2017 SETAC.

  6. Risk assessment based on current release standards for radioactive surface contamination

    International Nuclear Information System (INIS)

    Chen, S.Y.

    1993-09-01

    Standards for uncontrolled releases of radioactive surface contamination have been in existence in the United States for about two decades. Such standards have been issued by various agencies, including the US Department of Energy. This paper reviews the technical basis of published standards, identifies areas in need of revision, provides risk interpretations based on current technical knowledge and the regulatory environment, and offers suggestions for improvements

  7. Lower limb spasticity assessment using an inertial sensor: a reliability study

    International Nuclear Information System (INIS)

    Sterpi, I; Colombo, R; Caroli, A; Meazza, E; Maggioni, G; Pistarini, C

    2013-01-01

    Spasticity is a common motor impairment in patients with neurological disorders that can prevent functional recovery after rehabilitation. In the clinical setting, its assessment is carried out using standardized clinical scales. The aim of this study was to verify the applicability of inertial sensors for an objective measurement of quadriceps spasticity and evaluate its test–retest and inter-rater reliability during the implementation of the Wartenberg pendulum test. Ten healthy subjects and 11 patients in vegetative state with severe brain damage were enrolled in this study. Subjects were evaluated three times on three consecutive days. The test–retest reliability of measurement was assessed in the first two days. The third day was devoted to inter-rater reliability assessment. In addition, the lower limb muscle tone was bilaterally evaluated at the knee joint by the modified Ashworth scale. The factorial ANOVA analysis showed that the implemented method allowed us to discriminate between healthy and pathological conditions. The fairly low SEM and high ICC values obtained for the pendulum parameters indicated a good test–retest and inter-rater reliability of measurement. This study shows that an inertial sensor can be reliably used to characterize leg kinematics during the Wartenberg pendulum test and provide quantitative evaluation of quadriceps spasticity. (paper)

  8. A Standardized Narrative Profile Approach to Self-Reflection and Assessment of Cross-Cultural Communication

    Directory of Open Access Journals (Sweden)

    Kyle J Wilby

    2017-03-01

    Full Text Available Objectives: 1 to explore clinical assessor’s values regarding behaviours related to cultural aspects of care, 2 to generate standardized narrative profiles regarding cultural behavioural outcomes within clinical teaching settings, and 3 to rank order standardized narrative profiles according to performance expectations. Methods: Ten interviews were completed with clinicians to determine values and performance expectations for culturally competent behaviours. Transcripts were produced and coded. Six narrative profiles were developed based on data obtained. Twenty clinicians categorized profiles according to performance expectations and rank ordered. Intraclass correlation coefficients (ICCs determined inter-rater reliability. Clinicians rated usability of profiles in clinical training settings. Results: Eighteen categories were coded with communication, awareness and ability most frequently reported with each ranging from 9.6-11.5% of the utterances. Consensus for categorization of all profiles was achieved at a level of 70% (ICC = 0.837, 95% CI 0.654-0.969. High inter-rater reliability was achieved for rank ordering (ICC = 0.815, 95% CI 0.561 to 0.984. Seventeen (85% clinicians agreed that the profiles would be usable in clinical training settings. Conclusions: Standardized narrative profiles may aid assessment and self-reflection for student performance within culturally diverse interactions. Conflict of Interest We declare no conflicts of interest or financial interests that the authors or members of their immediate families have in any product or service discussed in the manuscript, including grants (pending or received, employment, gifts, stock holdings or options, honoraria, consultancies, expert testimony, patents and royalties.   Type: Original Research

  9. Analysis of Item-Level Bias in the Bayley-III Language Subscales: The Validity and Utility of Standardized Language Assessment in a Multilingual Setting.

    Science.gov (United States)

    Goh, Shaun K Y; Tham, Elaine K H; Magiati, Iliana; Sim, Litwee; Sanmugam, Shamini; Qiu, Anqi; Daniel, Mary L; Broekman, Birit F P; Rifkin-Graboi, Anne

    2017-09-18

    The purpose of this study was to improve standardized language assessments among bilingual toddlers by investigating and removing the effects of bias due to unfamiliarity with cultural norms or a distributed language system. The Expressive and Receptive Bayley-III language scales were adapted for use in a multilingual country (Singapore). Differential item functioning (DIF) was applied to data from 459 two-year-olds without atypical language development. This involved investigating if the probability of success on each item varied according to language exposure while holding latent language ability, gender, and socioeconomic status constant. Associations with language, behavioral, and emotional problems were also examined. Five of 16 items showed DIF, 1 of which may be attributed to cultural bias and another to a distributed language system. The remaining 3 items favored toddlers with higher bilingual exposure. Removal of DIF items reduced associations between language scales and emotional and language problems, but improved the validity of the expressive scale from poor to good. Our findings indicate the importance of considering cultural and distributed language bias in standardized language assessments. We discuss possible mechanisms influencing performance on items favoring bilingual exposure, including the potential role of inhibitory processing.

  10. PIAAC Technical Standards and Guidelines

    Science.gov (United States)

    OECD Publishing, 2014

    2014-01-01

    The Programme for International Assessment of Adult Competencies (PIAAC) will establish technical standards and guidelines to ensure that the survey design and implementation processes of PIAAC yield high-quality and internationally comparable data. This document provides a revised version of the technical standards and guidelines originally…

  11. Assessing the costs and benefits of US renewable portfolio standards

    Science.gov (United States)

    Wiser, Ryan; Mai, Trieu; Millstein, Dev; Barbose, Galen; Bird, Lori; Heeter, Jenny; Keyser, David; Krishnan, Venkat; Macknick, Jordan

    2017-09-01

    Renewable portfolio standards (RPS) exist in 29 US states and the District of Columbia. This article summarizes the first national-level, integrated assessment of the future costs and benefits of existing RPS policies; the same metrics are evaluated under a second scenario in which widespread expansion of these policies is assumed to occur. Depending on assumptions about renewable energy technology advancement and natural gas prices, existing RPS policies increase electric system costs by as much as 31 billion, on a present-value basis over 2015-2050. The expanded renewable deployment scenario yields incremental costs that range from 23 billion to 194 billion, depending on the assumptions employed. The monetized value of improved air quality and reduced climate damages exceed these costs. Using central assumptions, existing RPS policies yield 97 billion in air-pollution health benefits and 161 billion in climate damage reductions. Under the expanded RPS case, health benefits total 558 billion and climate benefits equal 599 billion. These scenarios also yield benefits in the form of reduced water use. RPS programs are not likely to represent the most cost effective path towards achieving air quality and climate benefits. Nonetheless, the findings suggest that US RPS programs are, on a national basis, cost effective when considering externalities.

  12. California Diploma Project Technical Report II: Alignment Study--Alignment Study of the Health Sciences and Medical Technology Draft Standards and California's Exit Level Common Core State Standards

    Science.gov (United States)

    McGaughy, Charis; de Gonzalez, Alicia

    2012-01-01

    The California Department of Education is in the process of revising the Career and Technical Education (CTE) Model Curriculum Standards. The Educational Policy Improvement Center (EPIC) conducted an investigation of the draft version of the Health Sciences and Medical Technology Standards (Health Science). The purpose of the study is to…

  13. CP Studies and Non-Standard Higgs Physics

    DEFF Research Database (Denmark)

    Kraml, S.; Accomando, E.; G. Akeroyd, A.

    2006-01-01

    There are many possibilities for new physics beyond the Standard Model that feature non-standard Higgs sectors. These may introduce new sources of CP violation, and there may be mixing between multiple Higgs bosons or other new scalar bosons. Alternatively, the Higgs may be a composite state......, or there may even be no Higgs at all. These non-standard Higgs scenarios have important implications for collider physics as well as for cosmology, and understanding their phenomenology is essential for a full comprehension of electroweak symmetry breaking. This report discusses the most relevant theories...

  14. Standardized Assessment of Biodiversity Trends in Tropical Forest Protected Areas: The End Is Not in Sight.

    Directory of Open Access Journals (Sweden)

    Lydia Beaudrot

    2016-01-01

    Full Text Available Extinction rates in the Anthropocene are three orders of magnitude higher than background and disproportionately occur in the tropics, home of half the world's species. Despite global efforts to combat tropical species extinctions, lack of high-quality, objective information on tropical biodiversity has hampered quantitative evaluation of conservation strategies. In particular, the scarcity of population-level monitoring in tropical forests has stymied assessment of biodiversity outcomes, such as the status and trends of animal populations in protected areas. Here, we evaluate occupancy trends for 511 populations of terrestrial mammals and birds, representing 244 species from 15 tropical forest protected areas on three continents. For the first time to our knowledge, we use annual surveys from tropical forests worldwide that employ a standardized camera trapping protocol, and we compute data analytics that correct for imperfect detection. We found that occupancy declined in 22%, increased in 17%, and exhibited no change in 22% of populations during the last 3-8 years, while 39% of populations were detected too infrequently to assess occupancy changes. Despite extensive variability in occupancy trends, these 15 tropical protected areas have not exhibited systematic declines in biodiversity (i.e., occupancy, richness, or evenness at the community level. Our results differ from reports of widespread biodiversity declines based on aggregated secondary data and expert opinion and suggest less extreme deterioration in tropical forest protected areas. We simultaneously fill an important conservation data gap and demonstrate the value of large-scale monitoring infrastructure and powerful analytics, which can be scaled to incorporate additional sites, ecosystems, and monitoring methods. In an era of catastrophic biodiversity loss, robust indicators produced from standardized monitoring infrastructure are critical to accurately assess population outcomes

  15. Standardized Assessment of Biodiversity Trends in Tropical Forest Protected Areas: The End Is Not in Sight.

    Science.gov (United States)

    Beaudrot, Lydia; Ahumada, Jorge A; O'Brien, Timothy; Alvarez-Loayza, Patricia; Boekee, Kelly; Campos-Arceiz, Ahimsa; Eichberg, David; Espinosa, Santiago; Fegraus, Eric; Fletcher, Christine; Gajapersad, Krisna; Hallam, Chris; Hurtado, Johanna; Jansen, Patrick A; Kumar, Amit; Larney, Eileen; Lima, Marcela Guimarães Moreira; Mahony, Colin; Martin, Emanuel H; McWilliam, Alex; Mugerwa, Badru; Ndoundou-Hockemba, Mireille; Razafimahaimodison, Jean Claude; Romero-Saltos, Hugo; Rovero, Francesco; Salvador, Julia; Santos, Fernanda; Sheil, Douglas; Spironello, Wilson R; Willig, Michael R; Winarni, Nurul L; Zvoleff, Alex; Andelman, Sandy J

    2016-01-01

    Extinction rates in the Anthropocene are three orders of magnitude higher than background and disproportionately occur in the tropics, home of half the world's species. Despite global efforts to combat tropical species extinctions, lack of high-quality, objective information on tropical biodiversity has hampered quantitative evaluation of conservation strategies. In particular, the scarcity of population-level monitoring in tropical forests has stymied assessment of biodiversity outcomes, such as the status and trends of animal populations in protected areas. Here, we evaluate occupancy trends for 511 populations of terrestrial mammals and birds, representing 244 species from 15 tropical forest protected areas on three continents. For the first time to our knowledge, we use annual surveys from tropical forests worldwide that employ a standardized camera trapping protocol, and we compute data analytics that correct for imperfect detection. We found that occupancy declined in 22%, increased in 17%, and exhibited no change in 22% of populations during the last 3-8 years, while 39% of populations were detected too infrequently to assess occupancy changes. Despite extensive variability in occupancy trends, these 15 tropical protected areas have not exhibited systematic declines in biodiversity (i.e., occupancy, richness, or evenness) at the community level. Our results differ from reports of widespread biodiversity declines based on aggregated secondary data and expert opinion and suggest less extreme deterioration in tropical forest protected areas. We simultaneously fill an important conservation data gap and demonstrate the value of large-scale monitoring infrastructure and powerful analytics, which can be scaled to incorporate additional sites, ecosystems, and monitoring methods. In an era of catastrophic biodiversity loss, robust indicators produced from standardized monitoring infrastructure are critical to accurately assess population outcomes and identify

  16. Standardized Assessment of Biodiversity Trends in Tropical Forest Protected Areas: The End Is Not in Sight

    Science.gov (United States)

    O'Brien, Timothy; Alvarez-Loayza, Patricia; Boekee, Kelly; Campos-Arceiz, Ahimsa; Eichberg, David; Espinosa, Santiago; Fegraus, Eric; Fletcher, Christine; Gajapersad, Krisna; Hallam, Chris; Hurtado, Johanna; Jansen, Patrick A.; Kumar, Amit; Larney, Eileen; Lima, Marcela Guimarães Moreira; Mahony, Colin; Martin, Emanuel H.; McWilliam, Alex; Mugerwa, Badru; Ndoundou-Hockemba, Mireille; Razafimahaimodison, Jean Claude; Romero-Saltos, Hugo; Rovero, Francesco; Salvador, Julia; Santos, Fernanda; Sheil, Douglas; Spironello, Wilson R.; Willig, Michael R.; Winarni, Nurul L.; Zvoleff, Alex; Andelman, Sandy J.

    2016-01-01

    Extinction rates in the Anthropocene are three orders of magnitude higher than background and disproportionately occur in the tropics, home of half the world’s species. Despite global efforts to combat tropical species extinctions, lack of high-quality, objective information on tropical biodiversity has hampered quantitative evaluation of conservation strategies. In particular, the scarcity of population-level monitoring in tropical forests has stymied assessment of biodiversity outcomes, such as the status and trends of animal populations in protected areas. Here, we evaluate occupancy trends for 511 populations of terrestrial mammals and birds, representing 244 species from 15 tropical forest protected areas on three continents. For the first time to our knowledge, we use annual surveys from tropical forests worldwide that employ a standardized camera trapping protocol, and we compute data analytics that correct for imperfect detection. We found that occupancy declined in 22%, increased in 17%, and exhibited no change in 22% of populations during the last 3–8 years, while 39% of populations were detected too infrequently to assess occupancy changes. Despite extensive variability in occupancy trends, these 15 tropical protected areas have not exhibited systematic declines in biodiversity (i.e., occupancy, richness, or evenness) at the community level. Our results differ from reports of widespread biodiversity declines based on aggregated secondary data and expert opinion and suggest less extreme deterioration in tropical forest protected areas. We simultaneously fill an important conservation data gap and demonstrate the value of large-scale monitoring infrastructure and powerful analytics, which can be scaled to incorporate additional sites, ecosystems, and monitoring methods. In an era of catastrophic biodiversity loss, robust indicators produced from standardized monitoring infrastructure are critical to accurately assess population outcomes and identify

  17. Environmental assessment in support of proposed interim energy conservation voluntary performance standards for new non-federal residential buildings: Volume 7

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-09-01

    The objective of this environmental assessment (EA) is to identify the potential environmental impacts that could result from the proposed voluntary residential standard (VOLRES) on private sector construction of new residential buildings. In this report, the scope, objectives, and approach of this EA are presented.

  18. Assessment of the accuracy and consistency in the application of standardized surveillance definitions: A summary of the American Journal of Infection Control and National Healthcare Safety Network case studies, 2010-2016.

    Science.gov (United States)

    Wright, Marc-Oliver; Allen-Bridson, Katherine; Hebden, Joan N

    2017-06-01

    The Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN) surveillance definitions are the most widely used criteria for health care-associated infection (HAI) surveillance. NHSN participants agree to conduct surveillance in accordance with the NHSN protocol and criteria. To assess the application of these standardized surveillance specifications and offer infection preventionists (IPs) opportunities for ongoing education, a series of case studies, with questions related to NHSN definitions and criteria were published. Beginning in 2010, case studies with multiple-choice questions based on standard surveillance criteria and protocols were written and published in the American Journal of Infection Control with a link to an online survey. Participants anonymously submitted their responses before receiving the correct answers. The 22 case studies had 7,950 respondents who provided 27,790 responses to 75 questions during the first 6 years. Correct responses were selected 62.5% of the time (17,376 out of 27,290), but ranged widely (16%-87%). In a subset analysis, 93% of participants self-identified as IPs (3,387 out of 3,640), 4.5% were public health professionals (163 out of 3,640), and 2.5% were physicians (90 out of 3,640). IPs responded correctly (62%) more often than physicians (55%) (P = .006). Among a cohort of voluntary participants, accurate application of surveillance criteria to case studies was suboptimal, highlighting the need for continuing education, competency development, and auditing. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.

  19. Achieving transparency in carbon labelling for construction materials – Lessons from current assessment standards and carbon labels

    International Nuclear Information System (INIS)

    Wu, Peng; Low, Sui Pheng; Xia, Bo; Zuo, Jian

    2014-01-01

    Highlights: • The evolution of international GHG standards is reviewed. • The evolution of international carbon labelling schemes is reviewed. • The transparency requirements in carbon labelling schemes are revealed. • Key recommendations are provided to improve transparency in carbon labelling. - Abstract: The construction industry is one of the largest sources of carbon emissions. Manufacturing of raw materials, such as cement, steel and aluminium, is energy intensive and has considerable impact on carbon emissions level. Due to the rising recognition of global climate change, the industry is under pressure to reduce carbon emissions. Carbon labelling schemes are therefore developed as meaningful yardsticks to measure and compare carbon emissions. Carbon labelling schemes can help switch consumer-purchasing habits to low-carbon alternatives. However, such switch is dependent on a transparent scheme. The principle of transparency is highlighted in all international greenhouse gas (GHG) standards, including the newly published ISO 14067: Carbon footprint of products – requirements and guidelines for quantification and communication. However, there are few studies which systematically investigate the transparency requirements in carbon labelling schemes. A comparison of five established carbon labelling schemes, namely the Singapore Green Labelling Scheme, the CarbonFree (the U.S.), the CO 2 Measured Label and the Reducing CO 2 Label (UK), the CarbonCounted (Canada), and the Hong Kong Carbon Labelling Scheme is therefore conducted to identify and investigate the transparency requirements. The results suggest that the design of current carbon labels have transparency issues relating but not limited to the use of a single sign to represent the comprehensiveness of the carbon footprint. These transparency issues are partially caused by the flexibility given to select system boundary in the life cycle assessment (LCA) methodology to measure GHG emissions. The

  20. A Standardized DNA Variant Scoring System for Pathogenicity Assessments in Mendelian Disorders.

    Science.gov (United States)

    Karbassi, Izabela; Maston, Glenn A; Love, Angela; DiVincenzo, Christina; Braastad, Corey D; Elzinga, Christopher D; Bright, Alison R; Previte, Domenic; Zhang, Ke; Rowland, Charles M; McCarthy, Michele; Lapierre, Jennifer L; Dubois, Felicita; Medeiros, Katelyn A; Batish, Sat Dev; Jones, Jeffrey; Liaquat, Khalida; Hoffman, Carol A; Jaremko, Malgorzata; Wang, Zhenyuan; Sun, Weimin; Buller-Burckle, Arlene; Strom, Charles M; Keiles, Steven B; Higgins, Joseph J

    2016-01-01

    We developed a rules-based scoring system to classify DNA variants into five categories including pathogenic, likely pathogenic, variant of uncertain significance (VUS), likely benign, and benign. Over 16,500 pathogenicity assessments on 11,894 variants from 338 genes were analyzed for pathogenicity based on prediction tools, population frequency, co-occurrence, segregation, and functional studies collected from internal and external sources. Scores were calculated by trained scientists using a quantitative framework that assigned differential weighting to these five types of data. We performed descriptive and comparative statistics on the dataset and tested interobserver concordance among the trained scientists. Private variants defined as variants found within single families (n = 5,182), were either VUS (80.5%; n = 4,169) or likely pathogenic (19.5%; n = 1,013). The remaining variants (n = 6,712) were VUS (38.4%; n = 2,577) or likely benign/benign (34.7%; n = 2,327) or likely pathogenic/pathogenic (26.9%, n = 1,808). Exact agreement between the trained scientists on the final variant score was 98.5% [95% confidence interval (CI) (98.0, 98.9)] with an interobserver consistency of 97% [95% CI (91.5, 99.4)]. Variant scores were stable and showed increasing odds of being in agreement with new data when re-evaluated periodically. This carefully curated, standardized variant pathogenicity scoring system provides reliable pathogenicity scores for DNA variants encountered in a clinical laboratory setting. © 2015 The Authors. **Human Mutation published by Wiley Periodicals, Inc.