WorldWideScience

Sample records for study assessing reproducibility

  1. Assessing Cognitive Performance in Badminton Players: A Reproducibility and Validity Study

    Directory of Open Access Journals (Sweden)

    van de Water Tanja

    2017-01-01

    Full Text Available Fast reaction and good inhibitory control are associated with elite sports performance. To evaluate the reproducibility and validity of a newly developed Badminton Reaction Inhibition Test (BRIT, fifteen elite (25 ± 4 years and nine non-elite (24 ± 4 years Dutch male badminton players participated in the study. The BRIT measured four components: domain-general reaction time, badminton-specific reaction time, domain-general inhibitory control and badminton-specific inhibitory control. Five participants were retested within three weeks on the badminton-specific components. Reproducibility was acceptable for badminton-specific reaction time (ICC = 0.626, CV = 6% and for badminton-specific inhibitory control (ICC = 0.317, CV = 13%. Good construct validity was shown for badminton-specific reaction time discriminating between elite and non-elite players (F = 6.650, p 0.05. Concurrent validity for domain-general reaction time was good, as it was associated with a national ranking for elite (p = 0.70, p 0.05. In conclusion, reproducibility and validity of inhibitory control assessment was not confirmed, however, the BRIT appears a reproducible and valid measure of reaction time in badminton players. Reaction time measured with the BRIT may provide input for training programs aiming to improve badminton players’ performance.

  2. Assessing Cognitive Performance in Badminton Players: A Reproducibility and Validity Study.

    Science.gov (United States)

    van de Water, Tanja; Huijgen, Barbara; Faber, Irene; Elferink-Gemser, Marije

    2017-01-01

    Fast reaction and good inhibitory control are associated with elite sports performance. To evaluate the reproducibility and validity of a newly developed Badminton Reaction Inhibition Test (BRIT), fifteen elite (25 ± 4 years) and nine non-elite (24 ± 4 years) Dutch male badminton players participated in the study. The BRIT measured four components: domain-general reaction time, badminton-specific reaction time, domain-general inhibitory control and badminton-specific inhibitory control. Five participants were retested within three weeks on the badminton-specific components. Reproducibility was acceptable for badminton-specific reaction time (ICC = 0.626, CV = 6%) and for badminton-specific inhibitory control (ICC = 0.317, CV = 13%). Good construct validity was shown for badminton-specific reaction time discriminating between elite and non-elite players (F = 6.650, p 0.05). Concurrent validity for domain-general reaction time was good, as it was associated with a national ranking for elite (p = 0.70, p badminton-specific reaction time, nor both components of inhibitory control (p > 0.05). In conclusion, reproducibility and validity of inhibitory control assessment was not confirmed, however, the BRIT appears a reproducible and valid measure of reaction time in badminton players. Reaction time measured with the BRIT may provide input for training programs aiming to improve badminton players' performance.

  3. The Dutch motor skills assessment as tool for talent development in table tennis: a reproducibility and validity study.

    Science.gov (United States)

    Faber, Irene R; Nijhuis-Van Der Sanden, Maria W G; Elferink-Gemser, Marije T; Oosterveld, Frits G J

    2015-01-01

    A motor skills assessment could be helpful in talent development by estimating essential perceptuo-motor skills of young players, which are considered requisite to develop excellent technical and tactical qualities. The Netherlands Table Tennis Association uses a motor skills assessment in their talent development programme consisting of eight items measuring perceptuo-motor skills specific to table tennis under varying conditions. This study aimed to investigate this assessment regarding its reproducibility, internal consistency, underlying dimensions and concurrent validity in 113 young table tennis players (6-10 years). Intraclass correlation coefficients of six test items met the criteria of 0.7 with coefficients of variation between 3% and 8%. Cronbach's alpha valued 0.853 for internal consistency. The principal components analysis distinguished two conceptually meaningful factors: "ball control" and "gross motor function." Concurrent validity analyses demonstrated moderate associations between the motor skills assessment's results and national ranking; boys r = -0.53 (P motor skills assessment seems to be a reproducible, objective part of a talent development programme, more longitudinal studies are required to investigate its predictive validity.

  4. Reproducibility of abdominal fat assessment by ultrasound and computed tomography.

    Science.gov (United States)

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.

  5. Assessment of precision and reproducibility of a new myograph

    Directory of Open Access Journals (Sweden)

    Piepenbrock Siegfried

    2007-12-01

    Full Text Available Abstract Background The physiological characteristics of muscle activity and the assessment of muscle strength represent important diagnostic information. There are many devices that measure muscle force in humans, but some require voluntary contractions, which are difficult to assess in weak or unconscious patients who are unable to complete a full range of voluntary force assessment tasks. Other devices, which obtain standard muscle contractions by electric stimulations, do not have the technology required to induce and measure reproducible valid contractions at the optimum muscle length. Methods In our study we used a newly developed diagnostic device which measures accurately the reproducibility and time-changed-variability of the muscle force in an individual muscle. A total of 500 in-vivo measurements of supra-maximal isometric single twitch contractions were carried out on the musculus adductor pollicis of 5 test subjects over 10 sessions, with ten repetitions per session. The same protocol was performed on 405 test subjects with two repetitions each to determine a reference-interval on healthy subjects. Results Using our test setting, we found a high reproducibility of the muscle contractions of each test subject. The precision of the measurements performed with our device was 98.74%. Only two consecutive measurements are needed in order to assess a real, representative individual value of muscle force. The mean value of the force of contraction was 9.51 N and the 95% reference interval was 4.77–14.25 N. Conclusion The new myograph is a highly reliable measuring device with which the adductor pollicis can be investigated at the optimum length. It has the potential to become a reliable and valid tool for diagnostic in the clinical setting and for monitoring neuromuscular diseases.

  6. Reproducibility of abdominal fat assessment by ultrasound and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaete; Benedeti, Augusto Cesar Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge, E-mail: fernando@fatesa.edu.br [Faculdade de Tecnologia em Saude (FATESA), Ribeirao Preto, SP (Brazil); Universidade de Fortaleza (UNIFOR), Fortaleza, CE (Brazil). Departmento de Radiologia; Universidade de Sao Paulo (FMRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Departmento de Medicina Clinica; Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras; Hospital Mae de Deus, Porto Alegre, RS (Brazil)

    2017-05-15

    Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. (author)

  7. Inter- and intra-laboratory study to determine the reproducibility of toxicogenomics datasets.

    Science.gov (United States)

    Scott, D J; Devonshire, A S; Adeleye, Y A; Schutte, M E; Rodrigues, M R; Wilkes, T M; Sacco, M G; Gribaldo, L; Fabbri, M; Coecke, S; Whelan, M; Skinner, N; Bennett, A; White, A; Foy, C A

    2011-11-28

    The application of toxicogenomics as a predictive tool for chemical risk assessment has been under evaluation by the toxicology community for more than a decade. However, it predominately remains a tool for investigative research rather than for regulatory risk assessment. In this study, we assessed whether the current generation of microarray technology in combination with an in vitro experimental design was capable of generating robust, reproducible data of sufficient quality to show promise as a tool for regulatory risk assessment. To this end, we designed a prospective collaborative study to determine the level of inter- and intra-laboratory reproducibility between three independent laboratories. All test centres (TCs) adopted the same protocols for all aspects of the toxicogenomic experiment including cell culture, chemical exposure, RNA extraction, microarray data generation and analysis. As a case study, the genotoxic carcinogen benzo[a]pyrene (B[a]P) and the human hepatoma cell line HepG2 were used to generate three comparable toxicogenomic data sets. High levels of technical reproducibility were demonstrated using a widely employed gene expression microarray platform. While differences at the global transcriptome level were observed between the TCs, a common subset of B[a]P responsive genes (n=400 gene probes) was identified at all TCs which included many genes previously reported in the literature as B[a]P responsive. These data show promise that the current generation of microarray technology, in combination with a standard in vitro experimental design, can produce robust data that can be generated reproducibly in independent laboratories. Future work will need to determine whether such reproducible in vitro model(s) can be predictive for a range of toxic chemicals with different mechanisms of action and thus be considered as part of future testing regimes for regulatory risk assessment. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Sixteen-row multislice computed tomography in the assessment of pulmonary veins prior to ablative treatment: validation vs conventional pulmonary venography and study of reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Maksimovic, R.; Cademartiri, F.; Pattynama, P.M.T. [Erasmus Medical Center, Rotterdam (Netherlands). Dept. of Radiology; Scholten, M; Jordaens, L.J. [Erasmus Medical Center, Rotterdam (Netherlands). Dept. of Cardiology

    2004-03-01

    The aim of this study was to validate multislice computed tomography (MSCT) venography measurements of pulmonary vein (PV) diameters vs conventional pulmonary venography (CPV), and to assess the reproducibility of MSCT data. The study included 21 consecutive patients with atrial fibrillation who were planned for cryothermal ablation of PVs. One day before ablation, all patients underwent CPV and contrast-enhanced non-gated MSCT venography. The MSCT was repeated 3 months after ablation. The CPV images of the treated PVs (n=40) were analyzed and compared with the results of MSCT measurements. Reproducibility of MSCT venography-based data was assessed by interobserver (n=84 PVs) and interexamination (n=44 PVs) variability. Pre-treatment PV diameters on MSCT and CPV showed good correlation (r=0.87, p<0.01; 18.9{+-}2.3 mm, 188.5{+-}2.4 mm, respectively). Interobserver agreement and interexamination reproducibility were good (r=0.91, r=0.82, respectively, p<0.01), with narrow limits of agreement (Bland and Altman method). The MSCT venography allows accurate and reproducible assessment of PVs. It can be used both in non-invasive planning of treatment for ablative therapy and in the follow-up of patients.

  9. Field assessment of balance in 10 to 14 year old children, reproducibility and validity of the Nintendo Wii board

    DEFF Research Database (Denmark)

    Larsen, Lisbeth Runge; Jørgensen, Martin Grønbech; Junge, Tina

    2014-01-01

    and adults. When assessing static balance, it is essential to use objective, sensitive tools, and these types of measurement have previously been performed in laboratory settings. However, the emergence of technologies like the Nintendo Wii Board (NWB) might allow balance assessment in field settings....... As the NWB has only been validated and tested for reproducibility in adults, the purpose of this study was to examine reproducibility and validity of the NWB in a field setting, in a population of children. METHODS: Fifty-four 10-14 year-olds from the CHAMPS-Study DK performed four different balance tests...... of the reproducibility study. CONCLUSION: Both NWB and AMTI have satisfactory reproducibility for testing static balance in a population of children. Concurrent validity of NWB compared with AMTI was satisfactory. Furthermore, the results from the concurrent validity study were comparable to the reproducibility results...

  10. Reproducibility in the assessment of acute pancreatitis with computed tomography

    International Nuclear Information System (INIS)

    Freire Filho, Edison de Oliveira; Vieira, Renata La Rocca; Yamada, Andre Fukunishi; Shigueoka, David Carlos; Bekhor, Daniel; Freire, Maxime Figueiredo de Oliveira; Ajzen, Sergio; D'Ippolito, Giuseppe

    2007-01-01

    Objective: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. Materials and methods: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index (κ). Results: Interobserver agreement was κ 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was κ = 0.796 and 0.732 for unenhanced morphological index; κ 0.725 and 0.802 for contrast- enhanced morphological index; κ = 0.674 and 0.849 for presence of pancreatic necrosis; κ = 0.606 and 0.770 for pancreatic necrosis extension; and κ = 0.801 and 0.687 for disease severity index at computed tomography. Conclusion: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast- enhancement does not affect the computed tomography morphological index reproducibility. (author)

  11. Validity and Reproducibility of the Iodine Dietary Intake Questionnaire Assessment Conducted for Young Polish Women

    Science.gov (United States)

    Malowaniec, Ewa

    2017-01-01

    The aim of this study was to analyse a designed brief iodine dietary intake questionnaire based on a food frequency assessment (IOdine Dietary INtake Evaluation-Food Frequency Questionnaire—IODINE-FFQ), including the assessment of validity and reproducibility in a group of 90 Polish women aged 20–35 years. Participants collected 3-day dietary records and filled in the IODINE-FFQ twice (FFQ1—directly after the dietary record and FFQ2—6 weeks later). The analysis included an assessment of validity (comparison with the results of the 3-day dietary record) and of reproducibility (comparison of the results obtained twice—FFQ1 and FFQ2). In the analysis of validity, a Bland-Altman index of 5.5% and 4.4% was recorded, respectively for FFQ1 and FFQ2. In the analysis of reproducibility it was 6.7%, but the share of individuals correctly classified into tertiles was over 70% (weighted κ of 0.675). It was stated, that assessment of IODINE-FFQ revealed a satisfactory level of validity and reproducibility in the analysis of Bland-Alman plot. The IODINE-FFQ may be indicated as a tool for the assessment of iodine intake in the young women in Poland, however further studies should be considered in order to obtain the practical tool for public health specialists. Due to the lack of validated iodine-specific food frequency questionnaires for countries of Eastern Europe, the IODINE-FFQ may be adjusted for courtiers other than Poland including iodine-fortified products. PMID:28661461

  12. Reproducibility of Tactile Assessments for Children with Unilateral Cerebral Palsy

    Science.gov (United States)

    Auld, Megan Louise; Ware, Robert S.; Boyd, Roslyn Nancy; Moseley, G. Lorimer; Johnston, Leanne Marie

    2012-01-01

    A systematic review identified tactile assessments used in children with cerebral palsy (CP), but their reproducibility is unknown. Sixteen children with unilateral CP and 31 typically developing children (TDC) were assessed 2-4 weeks apart. Test-retest percent agreements within one point for children with unilateral CP (and TDC) were…

  13. Reproducibility of qualitative assessments of temporal lobe atrophy in MRI studies.

    Science.gov (United States)

    Sarria-Estrada, S; Acevedo, C; Mitjana, R; Frascheri, L; Siurana, S; Auger, C; Rovira, A

    2015-01-01

    To determine the reproducibility of the Scheltens visual rating scale in establishing atrophy of the medial temporal lobe. We used coronal T1-weighted inversion recovery sequences on a 1.5 Tesla MRI scanner to study 25 patients with clinically diagnosed Alzheimer's disease or mild cognitive decline and 25 subjects without cognitive decline. Five neuroradiologists trained to apply the Scheltens visual rating scale analyzed the images. We used the interclass correlation coefficient to evaluate interrater and intrarater agreement. Raters scored 20 (80%) of the 25 patients with mild cognitive decline or Alzheimer's disease between 2 and 4; by contrast, they scored 21 (84%) of the 25 subjects without cognitive decline between 0 and 1. The interrater agreement was consistently greater than 0.82, with a 95% confidence interval of (0.7-0.9). The intrarater agreement ranged from 0.82 to 0.87, with a 95% confidence interval of (0.56-0.93). The Scheltens visual rating scale is reproducible among observers, and this finding supports its use in clinical practice. Copyright © 2013 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  14. Reproducibility of studies on text mining for citation screening in systematic reviews: Evaluation and checklist.

    Science.gov (United States)

    Olorisade, Babatunde Kazeem; Brereton, Pearl; Andras, Peter

    2017-09-01

    Independent validation of published scientific results through study replication is a pre-condition for accepting the validity of such results. In computation research, full replication is often unrealistic for independent results validation, therefore, study reproduction has been justified as the minimum acceptable standard to evaluate the validity of scientific claims. The application of text mining techniques to citation screening in the context of systematic literature reviews is a relatively young and growing computational field with high relevance for software engineering, medical research and other fields. However, there is little work so far on reproduction studies in the field. In this paper, we investigate the reproducibility of studies in this area based on information contained in published articles and we propose reporting guidelines that could improve reproducibility. The study was approached in two ways. Initially we attempted to reproduce results from six studies, which were based on the same raw dataset. Then, based on this experience, we identified steps considered essential to successful reproduction of text mining experiments and characterized them to measure how reproducible is a study given the information provided on these steps. 33 articles were systematically assessed for reproducibility using this approach. Our work revealed that it is currently difficult if not impossible to independently reproduce the results published in any of the studies investigated. The lack of information about the datasets used limits reproducibility of about 80% of the studies assessed. Also, information about the machine learning algorithms is inadequate in about 27% of the papers. On the plus side, the third party software tools used are mostly free and available. The reproducibility potential of most of the studies can be significantly improved if more attention is paid to information provided on the datasets used, how they were partitioned and utilized, and

  15. HiCRep: assessing the reproducibility of Hi-C data using a stratum-adjusted correlation coefficient.

    Science.gov (United States)

    Yang, Tao; Zhang, Feipeng; Yardımcı, Galip Gürkan; Song, Fan; Hardison, Ross C; Noble, William Stafford; Yue, Feng; Li, Qunhua

    2017-11-01

    Hi-C is a powerful technology for studying genome-wide chromatin interactions. However, current methods for assessing Hi-C data reproducibility can produce misleading results because they ignore spatial features in Hi-C data, such as domain structure and distance dependence. We present HiCRep, a framework for assessing the reproducibility of Hi-C data that systematically accounts for these features. In particular, we introduce a novel similarity measure, the stratum adjusted correlation coefficient (SCC), for quantifying the similarity between Hi-C interaction matrices. Not only does it provide a statistically sound and reliable evaluation of reproducibility, SCC can also be used to quantify differences between Hi-C contact matrices and to determine the optimal sequencing depth for a desired resolution. The measure consistently shows higher accuracy than existing approaches in distinguishing subtle differences in reproducibility and depicting interrelationships of cell lineages. The proposed measure is straightforward to interpret and easy to compute, making it well-suited for providing standardized, interpretable, automatable, and scalable quality control. The freely available R package HiCRep implements our approach. © 2017 Yang et al.; Published by Cold Spring Harbor Laboratory Press.

  16. Reproducibility of 201Tl myocardial imaging

    International Nuclear Information System (INIS)

    McLaughlin, P.R.; Martin, R.P.; Doherty, P.; Daspit, S.; Goris, M.; Haskell, W.; Lewis, S.; Kriss, J.P.; Harrison, D.C.

    1977-01-01

    Seventy-six thallium-201 myocardial perfusion studies were performed on twenty-five patients to assess their reproducibility and the effect of varying the level of exercise on the results of imaging. Each patient had a thallium-201 study at rest. Fourteen patients had studies on two occasions at maximum exercise, and twelve patients had studies both at light and at maximum exercise. Of 70 segments in the 14 patients assessed on each of two maximum exercise tests, 64 (91 percent) were reproducible. Only 53 percent (16/30) of the ischemic defects present at maximum exercise were seen in the light exercise study in the 12 patients assessed at two levels of exercise. Correlation of perfusion defects with arteriographically proven significant coronary stenosis was good for the left anterior descending and right coronary arteries, but not as good for circumflex artery disease. Thallium-201 myocardial imaging at maximum exercise is reproducible within acceptable limits, but careful attention to exercise technique is essential for valid comparative studies

  17. Reproducibility assessment of brain responses to visual food stimuli in adults with overweight and obesity.

    Science.gov (United States)

    Drew Sayer, R; Tamer, Gregory G; Chen, Ningning; Tregellas, Jason R; Cornier, Marc-Andre; Kareken, David A; Talavage, Thomas M; McCrory, Megan A; Campbell, Wayne W

    2016-10-01

    The brain's reward system influences ingestive behavior and subsequently obesity risk. Functional magnetic resonance imaging (fMRI) is a common method for investigating brain reward function. This study sought to assess the reproducibility of fasting-state brain responses to visual food stimuli using BOLD fMRI. A priori brain regions of interest included bilateral insula, amygdala, orbitofrontal cortex, caudate, and putamen. Fasting-state fMRI and appetite assessments were completed by 28 women (n = 16) and men (n = 12) with overweight or obesity on 2 days. Reproducibility was assessed by comparing mean fasting-state brain responses and measuring test-retest reliability of these responses on the two testing days. Mean fasting-state brain responses on day 2 were reduced compared with day 1 in the left insula and right amygdala, but mean day 1 and day 2 responses were not different in the other regions of interest. With the exception of the left orbitofrontal cortex response (fair reliability), test-retest reliabilities of brain responses were poor or unreliable. fMRI-measured responses to visual food cues in adults with overweight or obesity show relatively good mean-level reproducibility but considerable within-subject variability. Poor test-retest reliability reduces the likelihood of observing true correlations and increases the necessary sample sizes for studies. © 2016 The Obesity Society.

  18. Assessing the Validity and Reproducibility of an Iron Dietary Intake Questionnaire Conducted in a Group of Young Polish Women

    Science.gov (United States)

    Głąbska, Dominika; Guzek, Dominika; Ślązak, Joanna; Włodarek, Dariusz

    2017-01-01

    The aim of the study was to analyse a designed brief iron dietary intake questionnaire based on a food frequency assessment (IRONIC-FFQ—IRON Intake Calculation-Food Frequency Questionnaire), including the assessment of validity and reproducibility in a group of 75 Polish women aged 20–30 years. Participants conducted 3-day dietary records and filled in the IRONIC-FFQ twice (FFQ1—directly after the dietary record and FFQ2—6 weeks later). The analysis included an assessment of validity (comparison with the results of the 3-day dietary record) and of reproducibility (comparison of the results obtained twice—FFQ1 and FFQ2). In the analysis of validity, the share of individuals correctly classified into tertiles was over 50% (weighted κ of 0.36), while analysis of correlation revealed correlation coefficients of almost 0.5. In the assessment of reproducibility, almost 80% of individuals were correctly classified and less than 3% were misclassified (weighted κ of 0.73), while a correlation coefficient higher than 0.85 was obtained. Both in the assessment of validity and of reproducibility, a Bland–Altman index of 6.7% was recorded (93.3% of compared pairs of results were in the acceptable range, attributed to differences within ± 2SD limit). Validation of the IRONIC-FFQ revealed a satisfactory level of validity and positively validated reproducibility. PMID:28264423

  19. Reproducibility of radionuclide gastroesophageal reflux studies using quantitative parameters and potential role of quantitative assessment in follow-up

    International Nuclear Information System (INIS)

    Fatima, S.; Khursheed, K.; Nasir, W.; Saeed, M.A.; Fatmi, S.; Jafri, S.; Asghar, S.

    2004-01-01

    Radionuclide gastroesophageal reflux studies have been widely used in the assessment of gastroesophageal reflux disease (GERD) in infants and children. Various qualitative and quantitative parameters have been used for the interpretation of reflux studies but there is little consensus on the use of these parameters in routine gastroesophageal reflux scintigraphic studies. Aim of this study was to evaluate the methodological issues underlying the qualitative and quantitative assessment of gastroesophageal reflux and to determine the potential power of the reflux index calculation in follow-up assessment of the reflux positive patients. Methods: Total 147 patients suffering from recurrent lower respiratory tract infection, asthma and having strong clinical suspicion of GER were recruited in the study. Dynamic scintigraphic study was acquired for 30 minutes after oral administration of 99mTc phytate. Each study was analyzed three times by two nuclear medicine physicians. Clinical symptoms were graded according to predefined criteria and there correlation with severity reflux was done. Time activity curves were generated by drawing ROIs from esophagus. Reflux index was calculated by the standard formula and cut off value of 4% was used for RI calculation. Reflux indices were used for follow-up assessments in reflux positive patients. Kappa statistics and chi square test were used to evaluate the agreement and concordance between qualitative and quantitative parameters. Results: Tlae over all incidence of reflux in total study population was 63.94 %( 94 patients). The kappa value for both qualitative and quantitative parameters showed good agreement for intra and inter-observer reproducibility (kappa value > 0.75). Concordance between visual analysis and time activity curves was not observed. Reflux index and visuat interpretation shows concordance in the interpretation. The severity of clinical symptoms was directly related to the severity of the reflux observed in the

  20. Reproducibility of non-invasive assessment of skin endothelial function using laser Doppler flowmetry and laser speckle contrast imaging.

    Directory of Open Access Journals (Sweden)

    Cyril Puissant

    Full Text Available Endothelial dysfunction precedes atherosclerosis. Vasodilation induced by acetylcholine (ACh is a specific test of endothelial function. Reproducibility of laser techniques such as laser-Doppler-flowmetry (LDF and Laser-speckle-contrast-imaging (LSCI to detect ACh vasodilation is debated and results expressions lack standardization. We aimed to study at a 7-day interval (i the inter-subject reproducibility, (ii the intra-subjects reproducibility, and (iii the effect of the results expressions over variability.Using LDF and LSCI simultaneously, we performed two different ACh-iontophoresis protocols. The maximal ACh vasodilation (peak-ACh was expressed as absolute or normalized flow or conductance values. Inter-subject reproducibility was expressed as coefficient of variation (inter-CV,%. Intra-subject reproducibility was expressed as within subject coefficients of variation (intra-CV,%, and intra-class correlation coefficients (ICC. Fifteen healthy subjects were included. The inter-subject reproducibility of peak-ACh depended upon the expression of the results and ranged from 55% to 162% for LDF and from 17% to 83% for LSCI. The intra-subject reproducibility (intra-CV/ICC of peak-ACh was reduced when assessed with LSCI compared to LDF no matter how the results were expressed and whatever the protocol used. The highest intra-subject reproducibility was found using LSCI. It was 18.7%/0.87 for a single current stimulation (expressed as cutaneous vascular conductance and 11.4%/0.61 for multiple current stimulations (expressed as absolute value.ACh-iontophoresis coupled with LSCI is a promising test to assess endothelial function because it is reproducible, safe, and non-invasive. N°: NCT01664572.

  1. Genotypic variability enhances the reproducibility of an ecological study.

    Science.gov (United States)

    Milcu, Alexandru; Puga-Freitas, Ruben; Ellison, Aaron M; Blouin, Manuel; Scheu, Stefan; Freschet, Grégoire T; Rose, Laura; Barot, Sebastien; Cesarz, Simone; Eisenhauer, Nico; Girin, Thomas; Assandri, Davide; Bonkowski, Michael; Buchmann, Nina; Butenschoen, Olaf; Devidal, Sebastien; Gleixner, Gerd; Gessler, Arthur; Gigon, Agnès; Greiner, Anna; Grignani, Carlo; Hansart, Amandine; Kayler, Zachary; Lange, Markus; Lata, Jean-Christophe; Le Galliard, Jean-François; Lukac, Martin; Mannerheim, Neringa; Müller, Marina E H; Pando, Anne; Rotter, Paula; Scherer-Lorenzen, Michael; Seyhun, Rahme; Urban-Mead, Katherine; Weigelt, Alexandra; Zavattaro, Laura; Roy, Jacques

    2018-02-01

    Many scientific disciplines are currently experiencing a 'reproducibility crisis' because numerous scientific findings cannot be repeated consistently. A novel but controversial hypothesis postulates that stringent levels of environmental and biotic standardization in experimental studies reduce reproducibility by amplifying the impacts of laboratory-specific environmental factors not accounted for in study designs. A corollary to this hypothesis is that a deliberate introduction of controlled systematic variability (CSV) in experimental designs may lead to increased reproducibility. To test this hypothesis, we had 14 European laboratories run a simple microcosm experiment using grass (Brachypodium distachyon L.) monocultures and grass and legume (Medicago truncatula Gaertn.) mixtures. Each laboratory introduced environmental and genotypic CSV within and among replicated microcosms established in either growth chambers (with stringent control of environmental conditions) or glasshouses (with more variable environmental conditions). The introduction of genotypic CSV led to 18% lower among-laboratory variability in growth chambers, indicating increased reproducibility, but had no significant effect in glasshouses where reproducibility was generally lower. Environmental CSV had little effect on reproducibility. Although there are multiple causes for the 'reproducibility crisis', deliberately including genetic variability may be a simple solution for increasing the reproducibility of ecological studies performed under stringently controlled environmental conditions.

  2. Field assessment of balance in 10 to 14 year old children, reproducibility and validity of the Nintendo Wii board.

    Science.gov (United States)

    Larsen, Lisbeth Runge; Jørgensen, Martin Grønbech; Junge, Tina; Juul-Kristensen, Birgit; Wedderkopp, Niels

    2014-06-10

    Because body proportions in childhood are different to those in adulthood, children have a relatively higher centre of mass location. This biomechanical difference and the fact that children's movements have not yet fully matured result in different sway performances in children and adults. When assessing static balance, it is essential to use objective, sensitive tools, and these types of measurement have previously been performed in laboratory settings. However, the emergence of technologies like the Nintendo Wii Board (NWB) might allow balance assessment in field settings. As the NWB has only been validated and tested for reproducibility in adults, the purpose of this study was to examine reproducibility and validity of the NWB in a field setting, in a population of children. Fifty-four 10-14 year-olds from the CHAMPS-Study DK performed four different balance tests: bilateral stance with eyes open (1), unilateral stance on dominant (2) and non-dominant leg (3) with eyes open, and bilateral stance with eyes closed (4). Three rounds of the four tests were completed with the NWB and with a force platform (AMTI). To assess reproducibility, an intra-day test-retest design was applied with a two-hour break between sessions. Bland-Altman plots supplemented by Minimum Detectable Change (MDC) and concordance correlation coefficient (CCC) demonstrated satisfactory reproducibility for the NWB and the AMTI (MDC: 26.3-28.2%, CCC: 0.76-0.86) using Centre Of Pressure path Length as measurement parameter. Bland-Altman plots demonstrated satisfactory concurrent validity between the NWB and the AMTI, supplemented by satisfactory CCC in all tests (CCC: 0.74-0.87). The ranges of the limits of agreement in the validity study were comparable to the limits of agreement of the reproducibility study. Both NWB and AMTI have satisfactory reproducibility for testing static balance in a population of children. Concurrent validity of NWB compared with AMTI was satisfactory. Furthermore, the

  3. Assessing Cognitive Performance in Badminton Players : A Reproducibility and Validity Study

    NARCIS (Netherlands)

    van de Water, Tanja; Huijgen, Barbara; Faber, Irene R.; Elferink-Gemser, Marije

    2017-01-01

    Fast reaction and good inhibitory control are associated with elite sports performance. To evaluate the reproducibility and validity of a newly developed Badminton Reaction Inhibition Test (BRIT), fifteen elite (25 +/- 4 years) and nine non-elite (24 +/- 4 years) Dutch male badminton players

  4. Reproducibility and Validity of Dietary Patterns Assessed by a Food Frequency Questionnaire Used in the 5-Year Follow-Up Survey of the Japan Public Health Center-Based Prospective Study

    OpenAIRE

    Nanri, Akiko; Shimazu, Taichi; Ishihara, Junko; Takachi, Ribeka; Mizoue, Tetsuya; Inoue, Manami; Tsugane, Shoichiro

    2012-01-01

    Background Analysis of dietary pattern is increasingly popular in nutritional epidemiology. However, few studies have examined the validity and reproducibility of dietary patterns. We assessed the reproducibility and validity of dietary patterns identified by a food frequency questionnaire (FFQ) used in the 5-year follow-up survey of the Japan Public Health Center-Based Prospective Study (JPHC Study). Methods The participants were a subsample (244 men and 254 women) from the JPHC Study. Princ...

  5. Field assessment of balance in 10 to 14 year old children, reproducibility and validity of the Nintendo Wii board

    Science.gov (United States)

    2014-01-01

    Background Because body proportions in childhood are different to those in adulthood, children have a relatively higher centre of mass location. This biomechanical difference and the fact that children’s movements have not yet fully matured result in different sway performances in children and adults. When assessing static balance, it is essential to use objective, sensitive tools, and these types of measurement have previously been performed in laboratory settings. However, the emergence of technologies like the Nintendo Wii Board (NWB) might allow balance assessment in field settings. As the NWB has only been validated and tested for reproducibility in adults, the purpose of this study was to examine reproducibility and validity of the NWB in a field setting, in a population of children. Methods Fifty-four 10–14 year-olds from the CHAMPS-Study DK performed four different balance tests: bilateral stance with eyes open (1), unilateral stance on dominant (2) and non-dominant leg (3) with eyes open, and bilateral stance with eyes closed (4). Three rounds of the four tests were completed with the NWB and with a force platform (AMTI). To assess reproducibility, an intra-day test-retest design was applied with a two-hour break between sessions. Results Bland-Altman plots supplemented by Minimum Detectable Change (MDC) and concordance correlation coefficient (CCC) demonstrated satisfactory reproducibility for the NWB and the AMTI (MDC: 26.3-28.2%, CCC: 0.76-0.86) using Centre Of Pressure path Length as measurement parameter. Bland-Altman plots demonstrated satisfactory concurrent validity between the NWB and the AMTI, supplemented by satisfactory CCC in all tests (CCC: 0.74-0.87). The ranges of the limits of agreement in the validity study were comparable to the limits of agreement of the reproducibility study. Conclusion Both NWB and AMTI have satisfactory reproducibility for testing static balance in a population of children. Concurrent validity of NWB compared

  6. Reproducibility of somatosensory spatial perceptual maps.

    Science.gov (United States)

    Steenbergen, Peter; Buitenweg, Jan R; Trojan, Jörg; Veltink, Peter H

    2013-02-01

    Various studies have shown subjects to mislocalize cutaneous stimuli in an idiosyncratic manner. Spatial properties of individual localization behavior can be represented in the form of perceptual maps. Individual differences in these maps may reflect properties of internal body representations, and perceptual maps may therefore be a useful method for studying these representations. For this to be the case, individual perceptual maps need to be reproducible, which has not yet been demonstrated. We assessed the reproducibility of localizations measured twice on subsequent days. Ten subjects participated in the experiments. Non-painful electrocutaneous stimuli were applied at seven sites on the lower arm. Subjects localized the stimuli on a photograph of their own arm, which was presented on a tablet screen overlaying the real arm. Reproducibility was assessed by calculating intraclass correlation coefficients (ICC) for the mean localizations of each electrode site and the slope and offset of regression models of the localizations, which represent scaling and displacement of perceptual maps relative to the stimulated sites. The ICCs of the mean localizations ranged from 0.68 to 0.93; the ICCs of the regression parameters were 0.88 for the intercept and 0.92 for the slope. These results indicate a high degree of reproducibility. We conclude that localization patterns of non-painful electrocutaneous stimuli on the arm are reproducible on subsequent days. Reproducibility is a necessary property of perceptual maps for these to reflect properties of a subject's internal body representations. Perceptual maps are therefore a promising method for studying body representations.

  7. Relative validity and reproducibility of a food frequency questionnaire to assess dietary fiber intake in Danish adults.

    Science.gov (United States)

    Vuholm, Stine; Lorenzen, Janne K; Kristensen, Mette

    2014-01-01

    Differences in habitual dietary fiber intake may modify effects of dietary fiber interventions, thus measurement of habitual dietary fiber intake is relevant to apply in intervention studies on fiber-rich foods, and food frequency questionnaire (FFQ) is a commonly used method. Rye bread is the major contributor of dietary fiber in the Danish population, and a nation-specific FFQ is therefore needed. The aim of this study was to assess the relative validity and reproducibility of a self-administered quantitative FFQ designed to assess total dietary fiber intake among Danish adults. In order to assess the relative validity of the FFQ, a total of 125 participants completed both a 7-day weighed dietary recording (DR) and an FFQ consisting of 60 questions. To evaluate the reproducibility of the FFQ, a sub-group of 12 participants subsequently completed an FFQ approximately 6 months later. Estimates of mean dietary fiber intake were 24.9±9.8 and 28.1±9.4 g/day when applying the FFQ and DR, respectively, where FFQ estimates were ~12% lower (pfiber intake of the two methods was r=0.63 (pfiber intake (g/day), adequate ranking of subjects according to their dietary fiber intake, and good reproducibility. The FFQ is therefore believed to be a valuable tool for epidemiology and screening in human interventions, where intake of dietary fibers is of specific interest.

  8. Reproducibility of brain ADC histograms

    International Nuclear Information System (INIS)

    Steens, S.C.A.; Buchem, M.A. van; Admiraal-Behloul, F.; Schaap, J.A.; Hoogenraad, F.G.C.; Wheeler-Kingshott, C.A.M.; Tofts, P.S.; Cessie, S. le

    2004-01-01

    The aim of this study was to assess the effect of differences in acquisition technique on whole-brain apparent diffusion coefficient (ADC) histogram parameters, as well as to assess scan-rescan reproducibility. Diffusion-weighted imaging (DWI) was performed in 7 healthy subjects with b-values 0-800, 0-1000, and 0-1500 s/mm 2 and fluid-attenuated inversion recovery (FLAIR) DWI with b-values 0-1000 s/mm 2 . All sequences were repeated with and without repositioning. The peak location, peak height, and mean ADC of the ADC histograms and mean ADC of a region of interest (ROI) in the white matter were compared using paired-sample t tests. Scan-rescan reproducibility was assessed using paired-sample t tests, and repeatability coefficients were reported. With increasing maximum b-values, ADC histograms shifted to lower values, with an increase in peak height (p<0.01). With FLAIR DWI, the ADC histogram shifted to lower values with a significantly higher, narrower peak (p<0.01), although the ROI mean ADC showed no significant differences. For scan-rescan reproducibility, no significant differences were observed. Different DWI pulse sequences give rise to different ADC histograms. With a given pulse sequence, however, ADC histogram analysis is a robust and reproducible technique. Using FLAIR DWI, the partial-voluming effect of cerebrospinal fluid, and thus its confounding effect on histogram analyses, can be reduced

  9. Reproducibility of ultrasonography for assessing abdominal fat distribution in a population at high risk of diabetes

    DEFF Research Database (Denmark)

    Philipsen, A; Carstensen, Bendix; Sandbæk, Annelli

    2013-01-01

    the reproducibility of this method have been published.Objective:The aim of this study was to investigate the reproducibility of ultrasonography in the assessment of abdominal fat distribution in a population at high risk of type 2 diabetes.Design and Methods:Ultrasonography was used to estimate visceral......- and interobserver variation, and Bland-Altman plots were drawn for all three substudies.Results:Coefficients of variation for intra- and interobserver variation were in the range 3.4-6.1%, except for interobserver variation for subcutaneous fat (9.5%). Short-term variation over a median of 35 days had a coefficient...

  10. Assessment of the potential forecasting skill of a global hydrological model in reproducing the occurrence of monthly flow extremes

    Directory of Open Access Journals (Sweden)

    N. Candogan Yossef

    2012-11-01

    Full Text Available As an initial step in assessing the prospect of using global hydrological models (GHMs for hydrological forecasting, this study investigates the skill of the GHM PCR-GLOBWB in reproducing the occurrence of past extremes in monthly discharge on a global scale. Global terrestrial hydrology from 1958 until 2001 is simulated by forcing PCR-GLOBWB with daily meteorological data obtained by downscaling the CRU dataset to daily fields using the ERA-40 reanalysis. Simulated discharge values are compared with observed monthly streamflow records for a selection of 20 large river basins that represent all continents and a wide range of climatic zones.

    We assess model skill in three ways all of which contribute different information on the potential forecasting skill of a GHM. First, the general skill of the model in reproducing hydrographs is evaluated. Second, model skill in reproducing significantly higher and lower flows than the monthly normals is assessed in terms of skill scores used for forecasts of categorical events. Third, model skill in reproducing flood and drought events is assessed by constructing binary contingency tables for floods and droughts for each basin. The skill is then compared to that of a simple estimation of discharge from the water balance (PE.

    The results show that the model has skill in all three types of assessments. After bias correction the model skill in simulating hydrographs is improved considerably. For most basins it is higher than that of the climatology. The skill is highest in reproducing monthly anomalies. The model also has skill in reproducing floods and droughts, with a markedly higher skill in floods. The model skill far exceeds that of the water balance estimate. We conclude that the prospect for using PCR-GLOBWB for monthly and seasonal forecasting of the occurrence of hydrological extremes is positive. We argue that this conclusion applies equally to other similar GHMs and

  11. Handgrip force steadiness in young and older adults: a reproducibility study.

    Science.gov (United States)

    Blomkvist, Andreas W; Eika, Fredrik; de Bruin, Eling D; Andersen, Stig; Jorgensen, Martin

    2018-04-02

    Force steadiness is a quantitative measure of the ability to control muscle tonus. It is an independent predictor of functional performance and has shown to correlate well with different degrees of motor impairment following stroke. Despite being clinically relevant, few studies have assessed the validity of measuring force steadiness. The aim of this study was to explore the reproducibility of handgrip force steadiness, and to assess age difference in steadiness. Intrarater reproducibility (the degree to which a rating gives consistent result on separate occasions) was investigated in a test-retest design with seven days between sessions. Ten young and thirty older adults were recruited and handgrip steadiness was tested at 5%, 10% and 25% of maximum voluntary contraction (MVC) using Nintendo Wii Balance Board (WBB). Coefficients of variation were calculated from the mean force produced (CVM) and the target force (CVT). Area between the force curve and the target force line (Area) was also calculated. For the older adults we explored reliability using intraclass correlation coefficient (ICC) and agreement using standard error of measurement (SEM), limits of agreement (LOA) and smallest real difference (SRD). A systematic improvement in handgrip steadiness was found between sessions for all measures (CVM, CVT, Area). CVM and CVT at 5% of MVC showed good to high reliability, while Area had poor reliability for all percentages of MVC. Averaged ICC for CVM, CVT and Area was 0.815, 0.806 and 0.464, respectively. Averaged ICC on 5%, 10%, and 25% of MVC was 0.751, 0.667 and 0.668, respectively. Measures of agreement showed similar trends with better results for CVM and CVT than for Area. Young adults had better handgrip steadiness than older adults across all measures. The CVM and CVT measures demonstrated good reproducibility at lower percentages of MVC using the WBB, and could become relevant measures in the clinical setting. The Area measure had poor reproducibility

  12. A PHYSICAL ACTIVITY QUESTIONNAIRE: REPRODUCIBILITY AND VALIDITY

    Directory of Open Access Journals (Sweden)

    Nicolas Barbosa

    2007-12-01

    Full Text Available This study evaluates the Quantification de L'Activite Physique en Altitude chez les Enfants (QAPACE supervised self-administered questionnaire reproducibility and validity on the estimation of the mean daily energy expenditure (DEE on Bogotá's schoolchildren. The comprehension was assessed on 324 students, whereas the reproducibility was studied on a different random sample of 162 who were exposed twice to it. Reproducibility was assessed using both the Bland-Altman plot and the intra-class correlation coefficient (ICC. The validity was studied in a sample of 18 girls and 18 boys randomly selected, which completed the test - re-test study. The DEE derived from the questionnaire was compared with the laboratory measurement results of the peak oxygen uptake (Peak VO2 from ergo-spirometry and Leger Test. The reproducibility ICC was 0.96 (95% C.I. 0.95-0.97; by age categories 8-10, 0.94 (0.89-0. 97; 11-13, 0.98 (0.96- 0.99; 14-16, 0.95 (0.91-0.98. The ICC between mean TEE as estimated by the questionnaire and the direct and indirect Peak VO2 was 0.76 (0.66 (p<0.01; by age categories, 8-10, 11-13, and 14-16 were 0.89 (0.87, 0.76 (0.78 and 0.88 (0.80 respectively. The QAPACE questionnaire is reproducible and valid for estimating PA and showed a high correlation with the Peak VO2 uptake

  13. Assessing the reproducibility of high definition urethral pressure profilometry and its correlation with an air-charged system.

    Science.gov (United States)

    Klünder, Mario; Amend, Bastian; Sawodny, Oliver; Stenzl, Arnulf; Ederer, Michael; Kelp, Alexandra; Sievert, Karl-Dietrich; Feuer, Ronny

    2017-06-01

    Recently, a new urodynamic method for the assessment of stress urinary incontinence called high definition urethral pressure profilometry (HD-UPP) has been introduced. This method combines a novel microtip catheter with advanced signal processing to enable spatial data location and the reconstruction of a pressure image inside the urethra. In order to assess the reproducibility of HD-UPP data, we statistically evaluate HD-UPP datasets and compare them to data from a double balloon air-charged system. Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, urodynamic features are extracted, and compared to the air-charged system. Reproducibility of HD-UPP data is assessed by statistically evaluating consecutive, intra-individual datasets. HD-UPP delivers results in agreement with previous comparisons of microtip and air-charged systems. The average deviation of two consecutive, intra-individual pressure images is very low at 7 cm H 2 O. HD-UPP provides physicians with detailed information on the pressure distribution inside the urethra. Through comparison with an air-charged catheter, it is shown that HD-UPP delivers results in agreement with previous studies on the comparison of microtip and air-charged catheters. It provides excellent reproducibility, as the difference between sequentially measured profiles from the same minipig is significantly lower than the one between profiles from different minipigs. © 2016 Wiley Periodicals, Inc.

  14. Repeat: a framework to assess empirical reproducibility in biomedical research

    Directory of Open Access Journals (Sweden)

    Leslie D. McIntosh

    2017-09-01

    Full Text Available Abstract Background The reproducibility of research is essential to rigorous science, yet significant concerns of the reliability and verifiability of biomedical research have been recently highlighted. Ongoing efforts across several domains of science and policy are working to clarify the fundamental characteristics of reproducibility and to enhance the transparency and accessibility of research. Methods The aim of the proceeding work is to develop an assessment tool operationalizing key concepts of research transparency in the biomedical domain, specifically for secondary biomedical data research using electronic health record data. The tool (RepeAT was developed through a multi-phase process that involved coding and extracting recommendations and practices for improving reproducibility from publications and reports across the biomedical and statistical sciences, field testing the instrument, and refining variables. Results RepeAT includes 119 unique variables grouped into five categories (research design and aim, database and data collection methods, data mining and data cleaning, data analysis, data sharing and documentation. Preliminary results in manually processing 40 scientific manuscripts indicate components of the proposed framework with strong inter-rater reliability, as well as directions for further research and refinement of RepeAT. Conclusions The use of RepeAT may allow the biomedical community to have a better understanding of the current practices of research transparency and accessibility among principal investigators. Common adoption of RepeAT may improve reporting of research practices and the availability of research outputs. Additionally, use of RepeAT will facilitate comparisons of research transparency and accessibility across domains and institutions.

  15. Reproducibility of range of motion and muscle strength measurements in patients with hip osteoarthritis – an interrater study

    DEFF Research Database (Denmark)

    Poulsen, Erik; Christensen, Henrik Wulff; Penny, Jeannette Østergaard

    2012-01-01

    ABSTRACT: BACKGROUND: Assessment of range of motion (ROM) and muscle strength is fundamental in the clinical diagnosis of hip osteoarthritis (OA) but reproducibility of these measurements has mostly involved clinicians from secondary care and has rarely reported agreement parameters. Therefore......, the primary objective of the study was to determine the inter-rater reproducibility of ROM and muscle strength measurements. Furthermore, the reliability of the overall assessment of clinical hip OA was evaluated. Reporting is in accordance with proposed guidelines for the reporting of reliability...... differentiate between hips with or without osteoarthritis....

  16. A multicenter reproducibility study of single-voxel 1H-MRS of the medial temporal lobe

    International Nuclear Information System (INIS)

    Traeber, Frank; Block, Wolfgang; Guer, Okan; Schild, Hans H.; Freymann, Nikolaus; Heun, Reinhard; Jessen, Frank; Kucinski, Thomas; Hammen, Thilo; Ende, Gabriele; Pilatus, Ulrich; Hampel, Harald

    2006-01-01

    Proton magnetic resonance spectroscopy ( 1 H-MRS) has provided evidence for a reduction of N-acetyl-aspartate (NAA) in the medial temporal lobe (MTL) in cerebral disorders such as Alzheimer's Disease. Within the 1 H-MRS study of the German Research Network on Dementia, we determined the multicenter reproducibility of single-voxel 1 H-MRS of the MTL. At five sites with 1.5T MR systems, single-voxel 1 H spectra from the MTL of an identical healthy subject were measured. The same subject was also examined at one of the sites five times to assess intracenter stability. The protocol included water-suppressed spectra with TE 272 ms and TE 30 ms and unsuppressed spectra for absolute quantification of metabolite concentrations. The intracenter reproducibility of absolute NAA concentration, expressed as coefficient of variation (CV), was 1.8%. CV for the concentrations of creatine (Cr), choline (Cho), and myoinositol (MI) and for the ratios NAA/Cr, NAA/Cho, and MI/NAA varied by 11-16%. Intercenter CV was 3.9% for NAA and were below 10% for all other metabolites and metabolic ratios. Our study demonstrates that quantitative assessment of NAA with single-voxel MRS can be performed with high intercenter reproducibility. This is the basis for applying 1 H-MRS in large-scale early recognition and treatment studies in MTL affecting disorders. (orig.)

  17. Prospective study of the reproducibility of X-rays and CT scans for assessing trochanteric fracture comminution in the elderly: a series of 110 cases.

    Science.gov (United States)

    Isida, Ronald; Bariatinsky, Varenka; Kern, Gregory; Dereudre, Gregoire; Demondion, Xavier; Chantelot, Christophe

    2015-10-01

    Trochanteric fractures are common but difficult to analyse in the elderly on plain X-rays. Fixation failures are related to the severity of the comminution, but comminution and the degree of instability are not easy to determine on standard X-rays. Use of computed tomography (CT) improves assessment of complex fractures, but this finding has not been confirmed versus intraoperative data. The primary objective of this prospective study was to determine the error rate when evaluating comminution on X-rays and CT scans. The secondary objectives were to determine whether CT data on comminution and stability were consistent with intraoperative findings and to define the fracture characteristics. Standard X-ray assessment underestimates the complexity of trochanteric fractures and is not very reproducible. Between January and December 2013, all proximal femur fractures in the trochanter area of patients aged 75 years or older (mean age 85) were analysed prospectively with standard X-rays and computed tomography (CT). One hundred and ten patients (88 women and 22 men) with trochanteric fractures were included in the study. Fracture stability was evaluated using the Müller AO classification; the other fracture characteristics were evaluated independently. A senior surgeon evaluated the anonymised X-rays. A radiologist specialised in musculoskeletal imaging interpreted the CT scan images. All patients underwent total hip arthroplasty (110 patients) and 104 fixations of the greater trochanter. The X-ray and CT findings were compared to the intraoperative findings (gold standard) to evaluate their reproducibility. The reproducibility of the X-ray evaluation was poor for comminution, with a kappa of 0.4, sensitivity of 44 % and a negative predictive value of 29 % but a positive predictive value and specificity of 100 %. The CT evaluation had a kappa of 0.94, sensitivity of 95 % and negative predictive value of 79 %. According to the AO classification, unstable fractures were

  18. Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented

    NARCIS (Netherlands)

    Huisman, Jeroen; Egede, R.; Rdzanek, A.; Böse, D.; Erbel, R.; van der Palen, Jacobus Adrianus Maria; von Birgelen, Clemens

    2012-01-01

    To assess in a multicenter design the between-center reproducibility of volumetric virtual histology intravascular ultrasound (VH-IVUS) measurements with a semi-automated, computer-assisted contour detection system in coronary lesions that were consecutively stented. To evaluate the reproducibility

  19. Reproducibility of data-driven dietary patterns in two groups of adult Spanish women from different studies.

    Science.gov (United States)

    Castelló, Adela; Lope, Virginia; Vioque, Jesús; Santamariña, Carmen; Pedraz-Pingarrón, Carmen; Abad, Soledad; Ederra, Maria; Salas-Trejo, Dolores; Vidal, Carmen; Sánchez-Contador, Carmen; Aragonés, Nuria; Pérez-Gómez, Beatriz; Pollán, Marina

    2016-08-01

    The objective of the present study was to assess the reproducibility of data-driven dietary patterns in different samples extracted from similar populations. Dietary patterns were extracted by applying principal component analyses to the dietary information collected from a sample of 3550 women recruited from seven screening centres belonging to the Spanish breast cancer (BC) screening network (Determinants of Mammographic Density in Spain (DDM-Spain) study). The resulting patterns were compared with three dietary patterns obtained from a previous Spanish case-control study on female BC (Epidemiological study of the Spanish group for breast cancer research (GEICAM: grupo Español de investigación en cáncer de mama)) using the dietary intake data of 973 healthy participants. The level of agreement between patterns was determined using both the congruence coefficient (CC) between the pattern loadings (considering patterns with a CC≥0·85 as fairly similar) and the linear correlation between patterns scores (considering as fairly similar those patterns with a statistically significant correlation). The conclusions reached with both methods were compared. This is the first study exploring the reproducibility of data-driven patterns from two studies and the first using the CC to determine pattern similarity. We were able to reproduce the EpiGEICAM Western pattern in the DDM-Spain sample (CC=0·90). However, the reproducibility of the Prudent (CC=0·76) and Mediterranean (CC=0·77) patterns was not as good. The linear correlation between pattern scores was statistically significant in all cases, highlighting its arbitrariness for determining pattern similarity. We conclude that the reproducibility of widely prevalent dietary patterns is better than the reproducibility of more population-specific patterns. More methodological studies are needed to establish an objective measurement and threshold to determine pattern similarity.

  20. Reproducibility of cervical range of motion in patients with neck pain

    NARCIS (Netherlands)

    Pool, JJM; van Mameren, H; Deville, WJLM; Assendelft, WJJ; de Vet, HCW; de Winter, AF; Koes, BW; Bouter, LM; Hoving, J.L.

    2005-01-01

    Background: Reproducibility measurements of the range of motion are an important prerequisite for the interpretation of study results. The aim of the study is to assess the intra-rater and interrater reproducibility of the measurement of active Range of Motion ( ROM) in patients with neck pain using

  1. Robust tissue classification for reproducible wound assessment in telemedicine environments

    Science.gov (United States)

    Wannous, Hazem; Treuillet, Sylvie; Lucas, Yves

    2010-04-01

    In telemedicine environments, a standardized and reproducible assessment of wounds, using a simple free-handled digital camera, is an essential requirement. However, to ensure robust tissue classification, particular attention must be paid to the complete design of the color processing chain. We introduce the key steps including color correction, merging of expert labeling, and segmentation-driven classification based on support vector machines. The tool thus developed ensures stability under lighting condition, viewpoint, and camera changes, to achieve accurate and robust classification of skin tissues. Clinical tests demonstrate that such an advanced tool, which forms part of a complete 3-D and color wound assessment system, significantly improves the monitoring of the healing process. It achieves an overlap score of 79.3 against 69.1% for a single expert, after mapping on the medical reference developed from the image labeling by a college of experts.

  2. Repeatability and Reproducibility of Intraocular Pressure and Dynamic Corneal Response Parameters Assessed by the Corvis ST

    Directory of Open Access Journals (Sweden)

    Bernardo T. Lopes

    2017-01-01

    Full Text Available Purpose. To assess the repeatability and reproducibility of dynamic corneal response parameters measured by the Corvis ST (Oculus, Wetzlar, Germany. Methods. One eye randomly selected from 32 healthy volunteers was examined by the Corvis ST. Three different devices were used in an alternated random order for taking three measurements at each device in each subject. Standard intraocular pressure (IOP, the biomechanical-compensated IOP (bIOP, and DCR parameters were evaluated. The within-subject standard deviation (ζw and coefficient of variation (CV were assessed. Results. Regarding pressure indices, the ζw was below 1 mmHg for repeatability (0.98 for IOP and 0.89 for bIOP and the CV was 6.6% for IOP and 6.1% for bIOP. For reproducibility, the ζw was around 1 mmHg (1.12 for IOP and 1.05 for bIOP and the CV was 7.6% for IOP and 7.1% for bIOP. Most of DCR indices presented CV for repeatability below 4%. For reproducibility, the CV of most of the indices were below 6%. The deformation amplitude (DA ratio in 1 mm and integrated radius were below 4% (1.2% and 3.8%, resp.. Conclusions. The Corvis ST showed good precision (repeatability and reproducibility for IOP measurements and for DCR in healthy eyes.

  3. Reproducibility of cervical range of motion in patients with neck pain

    NARCIS (Netherlands)

    Hoving, Jan Lucas; Pool, Jan J. M.; van Mameren, Henk; Devillé, Walter J. L. M.; Assendelft, Willem J. J.; de Vet, Henrica C. W.; de Winter, Andrea F.; Koes, Bart W.; Bouter, Lex M.

    2005-01-01

    BACKGROUND: Reproducibility measurements of the range of motion are an important prerequisite for the interpretation of study results. The aim of the study is to assess the intra-rater and inter-rater reproducibility of the measurement of active Range of Motion (ROM) in patients with neck pain using

  4. Multi-site assessment of the precision and reproducibility of multiple reaction monitoring–based measurements of proteins in plasma

    Science.gov (United States)

    Addona, Terri A; Abbatiello, Susan E; Schilling, Birgit; Skates, Steven J; Mani, D R; Bunk, David M; Spiegelman, Clifford H; Zimmerman, Lisa J; Ham, Amy-Joan L; Keshishian, Hasmik; Hall, Steven C; Allen, Simon; Blackman, Ronald K; Borchers, Christoph H; Buck, Charles; Cardasis, Helene L; Cusack, Michael P; Dodder, Nathan G; Gibson, Bradford W; Held, Jason M; Hiltke, Tara; Jackson, Angela; Johansen, Eric B; Kinsinger, Christopher R; Li, Jing; Mesri, Mehdi; Neubert, Thomas A; Niles, Richard K; Pulsipher, Trenton C; Ransohoff, David; Rodriguez, Henry; Rudnick, Paul A; Smith, Derek; Tabb, David L; Tegeler, Tony J; Variyath, Asokan M; Vega-Montoto, Lorenzo J; Wahlander, Åsa; Waldemarson, Sofia; Wang, Mu; Whiteaker, Jeffrey R; Zhao, Lei; Anderson, N Leigh; Fisher, Susan J; Liebler, Daniel C; Paulovich, Amanda G; Regnier, Fred E; Tempst, Paul; Carr, Steven A

    2010-01-01

    Verification of candidate biomarkers relies upon specific, quantitative assays optimized for selective detection of target proteins, and is increasingly viewed as a critical step in the discovery pipeline that bridges unbiased biomarker discovery to preclinical validation. Although individual laboratories have demonstrated that multiple reaction monitoring (MRM) coupled with isotope dilution mass spectrometry can quantify candidate protein biomarkers in plasma, reproducibility and transferability of these assays between laboratories have not been demonstrated. We describe a multilaboratory study to assess reproducibility, recovery, linear dynamic range and limits of detection and quantification of multiplexed, MRM-based assays, conducted by NCI-CPTAC. Using common materials and standardized protocols, we demonstrate that these assays can be highly reproducible within and across laboratories and instrument platforms, and are sensitive to low µg/ml protein concentrations in unfractionated plasma. We provide data and benchmarks against which individual laboratories can compare their performance and evaluate new technologies for biomarker verification in plasma. PMID:19561596

  5. A multicenter reproducibility study of single-voxel {sup 1}H-MRS of the medial temporal lobe

    Energy Technology Data Exchange (ETDEWEB)

    Traeber, Frank; Block, Wolfgang; Guer, Okan; Schild, Hans H. [University of Bonn, Department of Radiology, Bonn (Germany); Freymann, Nikolaus; Heun, Reinhard; Jessen, Frank [University of Bonn, Department of Psychiatry, Bonn (Germany); Kucinski, Thomas [University of Hamburg, Department of Neuroradiology, Hamburg (Germany); Hammen, Thilo [University of Erlangen, Department of Psychiatry, Erlangen (Germany); Ende, Gabriele [Central Institute of Mental Health, NMR Research in Psychiatry, Mannheim (Germany); Pilatus, Ulrich [University of Frankfurt, Department of Neuroradiology, Frankfurt (Germany); Hampel, Harald [University of Munich, Department of Psychiatry, Munich (Germany)

    2006-05-15

    Proton magnetic resonance spectroscopy ({sup 1}H-MRS) has provided evidence for a reduction of N-acetyl-aspartate (NAA) in the medial temporal lobe (MTL) in cerebral disorders such as Alzheimer's Disease. Within the {sup 1}H-MRS study of the German Research Network on Dementia, we determined the multicenter reproducibility of single-voxel {sup 1}H-MRS of the MTL. At five sites with 1.5T MR systems, single-voxel {sup 1}H spectra from the MTL of an identical healthy subject were measured. The same subject was also examined at one of the sites five times to assess intracenter stability. The protocol included water-suppressed spectra with TE 272 ms and TE 30 ms and unsuppressed spectra for absolute quantification of metabolite concentrations. The intracenter reproducibility of absolute NAA concentration, expressed as coefficient of variation (CV), was 1.8%. CV for the concentrations of creatine (Cr), choline (Cho), and myoinositol (MI) and for the ratios NAA/Cr, NAA/Cho, and MI/NAA varied by 11-16%. Intercenter CV was 3.9% for NAA and were below 10% for all other metabolites and metabolic ratios. Our study demonstrates that quantitative assessment of NAA with single-voxel MRS can be performed with high intercenter reproducibility. This is the basis for applying {sup 1}H-MRS in large-scale early recognition and treatment studies in MTL affecting disorders. (orig.)

  6. Reproducibility of three-dimensional ultrasound for the measurement of a niche in a caesarean scar and assessment of its shape

    NARCIS (Netherlands)

    Bij de Vaate, A.J.M.; Linskens, I.H.; van der Voet, L.F.; Twisk, J.W.R.; Brölmann, H.A.M.; Huirne, J.A.F.

    2015-01-01

    Abstract Objective To evaluate the inter- and intraobserver agreement for measurement of the size and volume of a niche and assessment of the shape, with the use of three-dimensional (3D) ultrasound. Study design In this reproducibility study, 20 3D ultrasound volumes of uteri with a niche were

  7. A study on reproducibility of three-dimensional measurement for an evaluation of craniofacial morphology

    International Nuclear Information System (INIS)

    Nagai, Yoshihiro; Nishiyama, Hideyoshi; Nihara, Jun; Tanaka, Ray; Yamaki, Masaki; Hayashi, Takafumi; Saito, Isao

    2013-01-01

    Materials including facial and oral pictures, frontal and lateral cephalograms, dental casts and CT are essential for orthodontic diagnosis with orthognathic surgery. Although a three-dimensional analysis has been prevalent in diagnosing patients with dentofacial deformity, little information is available as to the definition and reproducibility of the measurement points when conducting a three-dimensional analysis using CT. This study was therefore designed to evaluate reproducibility of three-dimensional landmarks defined on the multiplaner reconstruction (MPR) images. Seven presurgical CT data obtained from seven orthognathic patients (4 females and 3 males) were selected. Two orthodontists independently repeated the identification of 44 landmarks defined twice on the MPR image with the reference plane of the Frankfurt horizontal plane (FH plane) using DICOM viewer Exavision Lite (Ziosoft, Tokyo). The significance of intra-examiner and inter-examiner errors was assessed using ANOVA, and reproducibility of landmarks was evaluated by the standard deviation (SD) value of measurement error. While no significant differences were found in intra-examiner measurement values, a significant difference was identified in inter-examiner measurement values at 39 coordinates among 132 coordinates; 10, 15, and 14 coordinates were found in X-, Y- and Z-coordinates, respectively. Reproducibility of ramus posterior point (Ar), Gonion (Go) and greater palatine foramen were particularly poor. However, reproducibility of landmarks adopted was considered enough for the analysis of maxillofacial morphology since the SDs of those landmarks were small as compared to voxel size. In case the FH plane is set as the reference plane, much more reproducible measurement landmarks may be selected without an influence of changes in head posture. (author)

  8. Within-person reproducibility of red blood cell mercury over a 10- to 15-year period among women in the Nurses' Health Study II

    DEFF Research Database (Denmark)

    Kioumourtzoglou, Marianthi-Anna; Roberts, Andrea L; Nielsen, Flemming

    2016-01-01

    Most epidemiologic studies of methylmercury (MeHg) health effects rely on a single measurement of a MeHg biomarker to assess long-term exposures. Long-term reproducibility data are, therefore, needed to assess the reliability of a single measure to reflect long-term exposures. In this study, we...... assessed within-person reproducibility of red blood cell (RBC) mercury (Hg), a marker of methyl-mercury, over 10-15 years in a sample of 57 women. Fifty-seven women from the Nurses' Health Study II provided two blood samples 10-15-years apart (median: 12 years), which were analyzed for mercury levels...... in the red blood cells (B-Hg*). To characterize within-person reproducibility, we estimated correlation and intraclass correlation coefficients (r and ICC) across the two samples. Further, we compared different prediction models, including variables on fish and seafood consumption, for B-Hg* at the first...

  9. Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography

    International Nuclear Information System (INIS)

    Nekolla, S.G.; Miethaner, C.; Nguyen, N.; Ziegler, S.I.; Schwaiger, M.

    1998-01-01

    The purpose of this study was to determine the reliability of new software developed for the analysis of cardiac tomographic data. The algorithm delineates the long axis and defines the basal plane and subsequently generates polar maps to quantitatively and reproducibly assess the size and severity of perfusion defects. The developed technique requires an initial manual estimate of the left ventricular long axis and calculates the volumetric maximum myocardial activity distribution. This surface is used to map three-dimensional tracer accumulation onto a two-dimensional representation (polar map), which is the basis for further processing. The spatial information is used to compute geometrical and mechanical properties of a solid model of the left ventricle including the left heart chamber. A new estimate of the axis is determined from this model, and the previously outlined procedure is repeated together with an automated definition of the valve plane until differences between the polar maps can be neglected. This quantitative analysis software was validated in phantom studies with defects of known masses and in ten data sets from normals and patients with coronary artery disease of various severity. We investigated the reproducibility of the maps with the introduction of a similarity criterion where the ratio of two corresponding polar map elements lies within a 10% interval. The maps were also used to measure intra-and interobserver variability in respect of defect size and severity. In the phantom studies, it was possible to reliably assess mass information over a wide range of defects from 5 to 60 g (slope: 1.02, offset -0.68, r = 0.972). Patient studies revealed a statistically significant increase in the reproducibility of the automatic technique compared with the manual approach: 54%±19% (manual) compared with 88%±9% (automatic) for observer 1 and 61%±20% vs 82%±5% for observer 2, respectively. The intervariability analysis showed a significant

  10. Validity and reproducibility of a physical activity questionnaire for older adults: questionnaire versus accelerometer for assessing physical activity in older adults

    NARCIS (Netherlands)

    Siebeling, Lara; Wiebers, Sarah; Beem, Leo; Puhan, Milo A.; ter Riet, Gerben

    2012-01-01

    BACKGROUND: Physical activity (PA) is important in older adults for the maintenance of functional ability. Assessing PA may be difficult. Few PA questionnaires have been compared to activity monitors. We examined reproducibility and validity of the self-administered Longitudinal Ageing Study

  11. Reproducibility of Manual Platelet Estimation Following Automated Low Platelet Counts

    Directory of Open Access Journals (Sweden)

    Zainab S Al-Hosni

    2016-11-01

    Full Text Available Objectives: Manual platelet estimation is one of the methods used when automated platelet estimates are very low. However, the reproducibility of manual platelet estimation has not been adequately studied. We sought to assess the reproducibility of manual platelet estimation following automated low platelet counts and to evaluate the impact of the level of experience of the person counting on the reproducibility of manual platelet estimates. Methods: In this cross-sectional study, peripheral blood films of patients with platelet counts less than 100 × 109/L were retrieved and given to four raters to perform manual platelet estimation independently using a predefined method (average of platelet counts in 10 fields using 100× objective multiplied by 20. Data were analyzed using intraclass correlation coefficient (ICC as a method of reproducibility assessment. Results: The ICC across the four raters was 0.840, indicating excellent agreement. The median difference of the two most experienced raters was 0 (range: -64 to 78. The level of platelet estimate by the least-experienced rater predicted the disagreement (p = 0.037. When assessing the difference between pairs of raters, there was no significant difference in the ICC (p = 0.420. Conclusions: The agreement between different raters using manual platelet estimation was excellent. Further confirmation is necessary, with a prospective study using a gold standard method of platelet counts.

  12. Identification and reproducibility of dietary patterns in a Danish cohort: the Inter99 study.

    Science.gov (United States)

    Lau, Cathrine; Glümer, Charlotte; Toft, Ulla; Tetens, Inge; Carstensen, Bendix; Jørgensen, Torben; Borch-Johnsen, Knut

    2008-05-01

    We aimed to identify dietary patterns in a Danish adult population and assess the reproducibility of the dietary patterns identified. Baseline data of 3,372 women and 3,191 men (30-60 years old) from the population-based survey Inter99 was used. Food intake, assessed by a FFQ, was aggregated into thirty-four separate food groups. Dietary patterns were identified by principal component analysis. Confirmatory factor analysis and Bland Altman plots were used to assess the reproducibility of the dietary patterns identified. The Bland Altman plots were used as an alternative and new method. Two factors were retained for both women and men, which accounted for 15.1-17.4 % of the total variation. The 'Traditional' pattern was characterised by high loadings ( > or = 0.40) on paté or high-fat meat for sandwiches, mayonnaise salads, red meat, potatoes, butter and lard, low-fat fish, low-fat meat for sandwiches, and sauces. The 'Modern' pattern was characterised by high loadings on vegetables, fruit, mixed vegetable dishes, vegetable oil and vinegar dressing, poultry, and pasta, rice and wheat kernels. Small differences were observed between patterns identified for women and men. The root mean square error approximation from the confirmatory factor analysis was 0.08. The variation observed from the Bland Altman plots of factors from explorative v. confirmative analyses and explorative analyses from two sub-samples was between 18.8 and 47.7 %. Pearson's correlation was >0.89 (P < 0.0001). The reproducibility was better for women than for men. We conclude that the 'Traditional' and 'Modern' dietary patterns identified were reproducible.

  13. Components of Variance when Assessing the Reproducibility of Body Composition Measurements using Bio-Impedance and the Hologic QDR-2000 DXA Scanner

    DEFF Research Database (Denmark)

    Jensen, Martin Bach; Hermann, Anne Pernille; Hessov, Ib

    1997-01-01

    This study evaluated the reproducibility of measuring lean tissue mass (LTM), fat mass(FM(DXA)), bone mineral content (BMC) and density (BMD) with a Hologic QDR-2000 DXA scanner, and both fat free mass (FFM(bio)) and fat mass (FM(bio)) with an impedance meter. Furthermore, the study aimed to assess...

  14. The intra-observer reproducibility of cardiovascular magnetic resonance myocardial feature tracking strain assessment is independent of field strength

    International Nuclear Information System (INIS)

    Schuster, Andreas; Morton, Geraint; Hussain, Shazia T.

    2013-01-01

    Background: Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a promising novel method for quantification of myocardial wall mechanics from standard steady-state free precession (SSFP) images. We sought to determine whether magnetic field strength affects the intra-observer reproducibility of CMR-FT strain analysis. Methods: We studied 2 groups, each consisting of 10 healthy subjects, at 1.5 T or 3 T Analysis was performed at baseline and after 4 weeks using dedicated CMR-FT prototype software (Tomtec, Germany) to analyze standard SSFP cine images. Right ventricular (RV) and left ventricular (LV) longitudinal strain (Ell RV and Ell LV ) and LV long-axis radial strain (Err LAX ) were derived from the 4-chamber cine, and LV short-axis circumferential and radial strains (Ecc SAX , Err SAX ) from the short-axis orientation. Strain parameters were assessed together with LV ejection fraction (EF) and volumes. Intra-observer reproducibility was determined by comparing the first and the second analysis in both groups. Results: In all volunteers resting strain parameters were successfully derived from the SSFP images. There was no difference in strain parameters, volumes and EF between field strengths (p > 0.05). In general Ecc SAX was the most reproducible strain parameter as determined by the coefficient of variation (CV) at 1.5 T (CV 13.3% and 46% global and segmental respectively) and 3 T (CV 17.2% and 31.1% global and segmental respectively). The least reproducible parameter was Ell RV (CV 1.5 T 28.7% and 53.2%; 3 T 43.5% and 63.3% global and segmental respectively). Conclusions: CMR-FT results are similar with reasonable intra-observer reproducibility in different groups of volunteers at 1.5 T and 3 T. CMR-FT is a promising novel technique and our data indicate that results might be transferable between field strengths. However there is a considerable amount of segmental variability indicating that further refinements are needed before CMR

  15. Short- and long-term reproducibility of radioisotopic examination of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Jonderko, K. (Silesian School of Medicine, Katowice (Poland). Dept. of Gastroenterology)

    1990-01-01

    Reproducibility of gastric emptying (GE) of a radiolabelled solid meal was assessed. The short-term reproducibility was evaluated on the basis of 12 paired GE examinations performed 1-3 days apart. Twelve paired GE examinations taken 3-8 months apart enabled long-term reproducibility assessment. Reproducibility of GE parameters was expressed in terms of the coefficient of variation, CV. No significant between-day variation of solid GE was found either regarding the short-term or the long-term reproducibility. Although slightly higher CV values characterized the long-term reproducibility of the GE parameters considered, the variations of the differences between repeated GE examinations did not differ significantly between short- and long-term GE reproducibility. The results obtained justify the use of radioisotopic GE measurement for the assessment of early and late results of pharmacologic or surgical management. (author).

  16. Assessment of ambulatory blood pressure monitoring: better reproducibility with polynomial analysis

    NARCIS (Netherlands)

    Cleophas, A. F.; Zwinderman, A. H.; Cleophas, T. J.

    2000-01-01

    Objective: Ambulatory blood pressure monitoring (ABPM) data using values of arbitrarily separated day- and nighttime hours are poorly reproducible, undermining the validity of this diagnostic tool. Previous studies from our group have demonstrated that polynomial curves can be produced of ABPM data

  17. Can cancer researchers accurately judge whether preclinical reports will reproduce?

    Directory of Open Access Journals (Sweden)

    Daniel Benjamin

    2017-06-01

    Full Text Available There is vigorous debate about the reproducibility of research findings in cancer biology. Whether scientists can accurately assess which experiments will reproduce original findings is important to determining the pace at which science self-corrects. We collected forecasts from basic and preclinical cancer researchers on the first 6 replication studies conducted by the Reproducibility Project: Cancer Biology (RP:CB to assess the accuracy of expert judgments on specific replication outcomes. On average, researchers forecasted a 75% probability of replicating the statistical significance and a 50% probability of replicating the effect size, yet none of these studies successfully replicated on either criterion (for the 5 studies with results reported. Accuracy was related to expertise: experts with higher h-indices were more accurate, whereas experts with more topic-specific expertise were less accurate. Our findings suggest that experts, especially those with specialized knowledge, were overconfident about the RP:CB replicating individual experiments within published reports; researcher optimism likely reflects a combination of overestimating the validity of original studies and underestimating the difficulties of repeating their methodologies.

  18. Validity and reproducibility of a food frequency questionnaire (FFQ) for dietary assessment in Malay adolescents in Malaysia.

    Science.gov (United States)

    Nurul-Fadhilah, Abdullah; Teo, Pey Sze; Foo, Leng Huat

    2012-01-01

    Food frequency questionnaire (FFQ) must be tailored to the target populations because dietary habits vary within the populations due to differences in cultural and lifestyles practices. Limited information is available to assess the validity of FFQ used among Malaysian adolescents. To construct the validity and reproducibility of a newly developed FFQ in assessing habitual nutrients intake over the past year of 170 Malay adolescent boys and girls in Kelantan, Malaysia. The FFQ that consisted of 124 food items was assessed, whereas three days of 24-hours dietary recalls (DR) was administered as the standard criteria method. Estimated mean intake for most nutrients assessed by the FFQ were higher as compared to the three DRs (pcross classification of quartile analysis showed that most nutrients were classified into the same or adjacent quartiles (median=52.7%). For the reproducibility of FFQ, the correlation of nutrients ranged from 0.43 for carotene to 0.86 for total fat intake (median=0.67), after adjusting for total energy intake. The newly developed dietary FFQ is a relatively good and valid tool in assessing habitual nutrients intake for the past year among Malay adolescents in Malaysia.

  19. The accuracy and reproducibility of video assessment in the pitch-side management of concussion in elite rugby.

    Science.gov (United States)

    Fuller, G W; Kemp, S P T; Raftery, M

    2017-03-01

    To investigate the accuracy and reliability of side-line video review of head impact events to aid identification of concussion in elite sport. Diagnostic accuracy and inter-rater agreement study. Immediate care, match day and team doctors involved in the 2015 Rugby Union World Cup viewed 20 video clips showing broadcaster's footage of head impact events occurring during elite Rugby matches. Subjects subsequently recorded whether any criteria warranting permanent removal from play or medical room head injury assessment were present. The accuracy of these ratings were compared to consensus expert opinion by calculating mean sensitivity and specificity across raters. The reproducibility of doctor's decisions was additionally assessed using raw agreement and Gwets AC1 chance corrected agreement coefficient. Forty rugby medicine doctors were included in the study. Compared to the expert reference standard overall sensitivity and specificity of doctors decisions were 77.5% (95% CI 73.1-81.5%) and 53.3% (95% CI 48.2-58.2%) respectively. Overall there was raw agreement of 67.8% (95% CI 57.9-77.7%) between doctors across all video clips. Chance corrected Gwets AC1 agreement coefficient was 0.39 (95% CI 0.17-0.62), indicating fair agreement. Rugby World Cup doctors' demonstrated moderate accuracy and fair reproducibility in head injury event decision making when assessing video clips of head impact events. The use of real-time video may improve the identification, decision making and management of concussion in elite sports. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  20. Virtual Raters for Reproducible and Objective Assessments in Radiology

    Science.gov (United States)

    Kleesiek, Jens; Petersen, Jens; Döring, Markus; Maier-Hein, Klaus; Köthe, Ullrich; Wick, Wolfgang; Hamprecht, Fred A.; Bendszus, Martin; Biller, Armin

    2016-04-01

    Volumetric measurements in radiologic images are important for monitoring tumor growth and treatment response. To make these more reproducible and objective we introduce the concept of virtual raters (VRs). A virtual rater is obtained by combining knowledge of machine-learning algorithms trained with past annotations of multiple human raters with the instantaneous rating of one human expert. Thus, he is virtually guided by several experts. To evaluate the approach we perform experiments with multi-channel magnetic resonance imaging (MRI) data sets. Next to gross tumor volume (GTV) we also investigate subcategories like edema, contrast-enhancing and non-enhancing tumor. The first data set consists of N = 71 longitudinal follow-up scans of 15 patients suffering from glioblastoma (GB). The second data set comprises N = 30 scans of low- and high-grade gliomas. For comparison we computed Pearson Correlation, Intra-class Correlation Coefficient (ICC) and Dice score. Virtual raters always lead to an improvement w.r.t. inter- and intra-rater agreement. Comparing the 2D Response Assessment in Neuro-Oncology (RANO) measurements to the volumetric measurements of the virtual raters results in one-third of the cases in a deviating rating. Hence, we believe that our approach will have an impact on the evaluation of clinical studies as well as on routine imaging diagnostics.

  1. Examining the Reproducibility of 6 Published Studies in Public Health Services and Systems Research.

    Science.gov (United States)

    Harris, Jenine K; B Wondmeneh, Sarah; Zhao, Yiqiang; Leider, Jonathon P

    2018-02-23

    Research replication, or repeating a study de novo, is the scientific standard for building evidence and identifying spurious results. While replication is ideal, it is often expensive and time consuming. Reproducibility, or reanalysis of data to verify published findings, is one proposed minimum alternative standard. While a lack of research reproducibility has been identified as a serious and prevalent problem in biomedical research and a few other fields, little work has been done to examine the reproducibility of public health research. We examined reproducibility in 6 studies from the public health services and systems research subfield of public health research. Following the methods described in each of the 6 papers, we computed the descriptive and inferential statistics for each study. We compared our results with the original study results and examined the percentage differences in descriptive statistics and differences in effect size, significance, and precision of inferential statistics. All project work was completed in 2017. We found consistency between original and reproduced results for each paper in at least 1 of the 4 areas examined. However, we also found some inconsistency. We identified incorrect transcription of results and omitting detail about data management and analyses as the primary contributors to the inconsistencies. Increasing reproducibility, or reanalysis of data to verify published results, can improve the quality of science. Researchers, journals, employers, and funders can all play a role in improving the reproducibility of science through several strategies including publishing data and statistical code, using guidelines to write clear and complete methods sections, conducting reproducibility reviews, and incentivizing reproducible science.

  2. Detection of animal-derived proteins in feedstuffs in Italy: a reproducibility study.

    Science.gov (United States)

    Ingravalle, Francesco; Abete, Maria Cesarina; Crescio, Maria Ines; Ru, Giuseppe

    2007-04-01

    Bovine spongiform encephalopathy is a prion disease of ruminants that was first recognized in 1986 in the United Kingdom. Early in the epidemic, it became obvious that the presence of meat and bone meal in feed rations was a common factor in all bovine spongiform encephalopathy cases. The first ban of derived animal proteins in feed was enforced in Europe in 1994 and implemented by Regulation 999/2001 that prohibited the feeding of animal-derived protein to farm animals. The only official method currently accepted by the European Union Commission for test for the presence of animal-derived proteins in feedstuffs is feed microscopy. In Italy, monitoring of feedstuff safety is provided by both the Ministry of Health and the Ministry of Agriculture. The quality of official control, usually assessed by verifying the reproducibility and the accuracy of the testing method, is of fundamental importance for all laboratories and institutions using these results for comparative purposes. The aims of this study were to assess the reproducibility of the official method over all the Italian surveillance network and to provide a model for evaluating the performance of the monitoring system. The accuracy of the identification of the animal class of derived protein detected (avian, mammalian, or aquatic organism) was assessed. The interlaboratory agreement within the overall network reached 0.97 (95% confidence interval of 0.95 to 0.98) for determining the presence or absence of animal-derived proteins (e.g., for mammalian, avian, or aquatic species), and specificity of the identification of the animal class indicated that fish proteins are more easily recognized than are avian or mammalian proteins.

  3. Shear wave elastography for breast masses is highly reproducible.

    Science.gov (United States)

    Cosgrove, David O; Berg, Wendie A; Doré, Caroline J; Skyba, Danny M; Henry, Jean-Pierre; Gay, Joel; Cohen-Bacrie, Claude

    2012-05-01

    To evaluate intra- and interobserver reproducibility of shear wave elastography (SWE) for breast masses. For intraobserver reproducibility, each observer obtained three consecutive SWE images of 758 masses that were visible on ultrasound. 144 (19%) were malignant. Weighted kappa was used to assess the agreement of qualitative elastographic features; the reliability of quantitative measurements was assessed by intraclass correlation coefficients (ICC). For the interobserver reproducibility, a blinded observer reviewed images and agreement on features was determined. Mean age was 50 years; mean mass size was 13 mm. Qualitatively, SWE images were at least reasonably similar for 666/758 (87.9%). Intraclass correlation for SWE diameter, area and perimeter was almost perfect (ICC ≥ 0.94). Intraobserver reliability for maximum and mean elasticity was almost perfect (ICC = 0.84 and 0.87) and was substantial for the ratio of mass-to-fat elasticity (ICC = 0.77). Interobserver agreement was moderate for SWE homogeneity (κ = 0.57), substantial for qualitative colour assessment of maximum elasticity (κ = 0.66), fair for SWE shape (κ = 0.40), fair for B-mode mass margins (κ = 0.38), and moderate for B-mode mass shape (κ = 0.58), orientation (κ = 0.53) and BI-RADS assessment (κ = 0.59). SWE is highly reproducible for assessing elastographic features of breast masses within and across observers. SWE interpretation is at least as consistent as that of BI-RADS ultrasound B-mode features. • Shear wave ultrasound elastography can measure the stiffness of breast tissue • It provides a qualitatively and quantitatively interpretable colour-coded map of tissue stiffness • Intraobserver reproducibility of SWE is almost perfect while intraobserver reproducibility of SWE proved to be moderate to substantial • The most reproducible SWE features between observers were SWE image homogeneity and maximum elasticity.

  4. Psychometric Evaluation of the Brachial Assessment Tool Part 1: Reproducibility.

    Science.gov (United States)

    Hill, Bridget; Williams, Gavin; Olver, John; Ferris, Scott; Bialocerkowski, Andrea

    2018-04-01

    To evaluate reproducibility (reliability and agreement) of the Brachial Assessment Tool (BrAT), a new patient-reported outcome measure for adults with traumatic brachial plexus injury (BPI). Prospective repeated-measure design. Outpatient clinics. Adults with confirmed traumatic BPI (N=43; age range, 19-82y). People with BPI completed the 31-item 4-response BrAT twice, 2 weeks apart. Results for the 3 subscales and summed score were compared at time 1 and time 2 to determine reliability, including systematic differences using paired t tests, test retest using intraclass correlation coefficient model 1,1 (ICC 1,1 ), and internal consistency using Cronbach α. Agreement parameters included standard error of measurement, minimal detectable change, and limits of agreement. BrAT. Test-retest reliability was excellent (ICC 1,1 =.90-.97). Internal consistency was high (Cronbach α=.90-.98). Measurement error was relatively low (standard error of measurement range, 3.1-8.8). A change of >4 for subscale 1, >6 for subscale 2, >4 for subscale 3, and >10 for the summed score is indicative of change over and above measurement error. Limits of agreement ranged from ±4.4 (subscale 3) to 11.61 (summed score). These findings support the use of the BrAT as a reproducible patient-reported outcome measure for adults with traumatic BPI with evidence of appropriate reliability and agreement for both individual and group comparisons. Further psychometric testing is required to establish the construct validity and responsiveness of the BrAT. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Reproducibility of the dynamics of facial expressions in unilateral facial palsy.

    Science.gov (United States)

    Alagha, M A; Ju, X; Morley, S; Ayoub, A

    2018-02-01

    The aim of this study was to assess the reproducibility of non-verbal facial expressions in unilateral facial paralysis using dynamic four-dimensional (4D) imaging. The Di4D system was used to record five facial expressions of 20 adult patients. The system captured 60 three-dimensional (3D) images per second; each facial expression took 3-4seconds which was recorded in real time. Thus a set of 180 3D facial images was generated for each expression. The procedure was repeated after 30min to assess the reproducibility of the expressions. A mathematical facial mesh consisting of thousands of quasi-point 'vertices' was conformed to the face in order to determine the morphological characteristics in a comprehensive manner. The vertices were tracked throughout the sequence of the 180 images. Five key 3D facial frames from each sequence of images were analyzed. Comparisons were made between the first and second capture of each facial expression to assess the reproducibility of facial movements. Corresponding images were aligned using partial Procrustes analysis, and the root mean square distance between them was calculated and analyzed statistically (paired Student t-test, PFacial expressions of lip purse, cheek puff, and raising of eyebrows were reproducible. Facial expressions of maximum smile and forceful eye closure were not reproducible. The limited coordination of various groups of facial muscles contributed to the lack of reproducibility of these facial expressions. 4D imaging is a useful clinical tool for the assessment of facial expressions. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt

    DEFF Research Database (Denmark)

    Højgaard, Michael V; Agner, Erik; Kanters, Jørgen K

    2005-01-01

    OBJECTIVE: Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS: We measured normal-to-normal heart beat...... pressures were extracted for the assessment of day-to-day and short-term reproducibility. Power spectrum analysis (Fourier) and transfer function analysis was performed. Reproducibility was assessed using the coefficient of variation (CV). The reproducibility of the mean RR interval, mean systolic......, diastolic and mean blood pressure was good (CVspectral parameters of HRV (CV range 18-36%) and BPV (16-44%) and moderate reproducibility of BRS (14-20%). CONCLUSION: Spectral estimates of BRS had only moderate reproducibility although...

  7. Superior Reproducibility of the Leading to Leading Edge and Inner to Inner Edge Methods in the Ultrasound Assessment of Maximum Abdominal Aortic Diameter

    DEFF Research Database (Denmark)

    Borgbjerg, Jens; Bøgsted, Martin; Lindholt, Jes S

    2018-01-01

    Objectives: Controversy exists regarding optimal caliper placement in ultrasound assessment of maximum abdominal aortic diameter. This study aimed primarily to determine reproducibility of caliper placement in relation to the aortic wall with the three principal methods: leading to leading edge...

  8. Validity and reproducibility of crutch force and heart rate measurements to assess energy expenditure of paraplegic gait

    NARCIS (Netherlands)

    IJzerman, Maarten Joost; Baardman, Gert; van 't Hof, Martin A.; Boom, H.B.K.; Hermens, Hermanus J.; Veltink, Petrus H.

    1999-01-01

    Objective: To determine the validity and reproducibility of heart rate (HR) and crutch force measurements to estimate energy expenditure during paraplegic walking. Usefulness of these outcome measures in comparative trials was assessed in terms of responsiveness. Design: Cross-sectional validity was

  9. Reproducibility and validity of patient-rated assessment of speech, swallowing, and saliva control in Parkinson’s Disease

    NARCIS (Netherlands)

    Machiel Zwarts; Johanna Kalf; Bastiaan Bloem; George Borm; Marten Munneke; Bert de Swart

    2012-01-01

    To report on the development and psychometric evaluation of the Radboud Oral Motor Inventory for Parkinson's Disease (ROMP), a newly developed patient-rated assessment of speech, swallowing, and saliva control in patients with Parkinson's disease (PD). To evaluate reproducibility, 60 patients

  10. Relative validity and reproducibility of a parent-administered semi-quantitative FFQ for assessing food intake in Danish children aged 3-9 years

    DEFF Research Database (Denmark)

    Buch-Andersen, Tine; Perez-Cueto, Armando; Toft, Ulla Marie Nørgaard

    2016-01-01

    OBJECTIVE: To assess the relative validity and reproducibility of the semi-quantitative FFQ (SFFQ) applied in the evaluation of a community intervention study, SoL-Bornholm, for estimating food intakes. DESIGN: The reference measure was a 4 d estimated food record. The SFFQ was completed two time...

  11. Validation and reproducibility of an Australian caffeine food frequency questionnaire.

    Science.gov (United States)

    Watson, E J; Kohler, M; Banks, S; Coates, A M

    2017-08-01

    The aim of this study was to measure validity and reproducibility of a caffeine food frequency questionnaire (C-FFQ) developed for the Australian population. The C-FFQ was designed to assess average daily caffeine consumption using four categories of food and beverages including; energy drinks; soft drinks/soda; coffee and tea and chocolate (food and drink). Participants completed a seven-day food diary immediately followed by the C-FFQ on two consecutive days. The questionnaire was first piloted in 20 adults, and then, a validity/reproducibility study was conducted (n = 90 adults). The C-FFQ showed moderate correlations (r = .60), fair agreement (mean difference 63 mg) and reasonable quintile rankings indicating fair to moderate agreement with the seven-day food diary. To test reproducibility, the C-FFQ was compared to itself and showed strong correlations (r = .90), good quintile rankings and strong kappa values (κ = 0.65), indicating strong reproducibility. The C-FFQ shows adequate validity and reproducibility and will aid researchers in Australia to quantify caffeine consumption.

  12. Reproducing a Prospective Clinical Study as a Computational Retrospective Study in MIMIC-II.

    Science.gov (United States)

    Kury, Fabrício S P; Huser, Vojtech; Cimino, James J

    2015-01-01

    In this paper we sought to reproduce, as a computational retrospective study in an EHR database (MIMIC-II), a recent large prospective clinical study: the 2013 publication, by the Japanese Association for Acute Medicine (JAAM), about disseminated intravascular coagulation, in the journal Critical Care (PMID: 23787004). We designed in SQL and Java a set of electronic phenotypes that reproduced the study's data sampling, and used R to perform the same statistical inference procedures. All produced source code is available online at https://github.com/fabkury/paamia2015. Our program identified 2,257 eligible patients in MIMIC-II, and the results remarkably agreed with the prospective study. A minority of the needed data elements was not found in MIMIC-II, and statistically significant inferences were possible in the majority of the cases.

  13. Reproducibility and Validity of a Food Frequency Questionnaire Designed to Assess Diet in Children Aged 4-5 Years.

    Science.gov (United States)

    Vioque, Jesus; Gimenez-Monzo, Daniel; Navarrete-Muñoz, Eva Maria; Garcia-de-la-Hera, Manuela; Gonzalez-Palacios, Sandra; Rebagliato, Marisa; Ballester, Ferran; Murcia, Mario; Iñiguez, Carmen; Granado, Fernando

    2016-01-01

    The food frequency questionnaire (FFQ) is the most efficient and cost-effective method to investigate the relationship between usual diet and disease in epidemiologic studies. Although FFQs have been validated in many adult populations worldwide, the number of valid FFQ in preschool children is very scarce. The aim of this study was to evaluate the reproducibility and validity of a semi-quantitative FFQ designed for children aged 4 to 5 years. In this study, we have included 169 children aged 4-5 years from the INMA project in Valencia, a population-based prospective cohort study of mothers and children in Spain. The 105-items FFQ was administered twice to the parents or care-givers of children over a 9-month period. Reproducibility was explored by comparing intake of nutrients by the FFQs, while validity was examined by comparing the nutrient values from the FFQs with the average nutrient values of three 24 hour dietary recall (24hDR) taken in the period, and also, with the concentration in blood specimens for several vitamins (carotenoids, folate, vitamin B12, vitamin C and α-tocopherol). Pearson correlation coefficients and de-attenuated correlation coefficients were calculated and we also evaluated misclassification by quintile distribution. All correlation coefficients for reproducibility for nutrients and major food groups were statistically significant; the average correlation coefficients for daily intake were 0.43 for food groups and 0.41 for nutrients. The average correlation coefficients for validity for daily intakes against 24hDR was r = 0.30, and the average for de-attenuated correlation coefficients was r = 0.44. When evaluating validity against the blood concentration of vitamins, statistically significant correlations were observed for vitamin C (0.35), lycopene (0.31), β-Cryptoxantin (0.40), and vitamin E (0.29); the average of correlation coefficients was r = 0.21. Despite some low to moderate correlations for reproducibility and validity

  14. Cervical vertebrae maturation method morphologic criteria: poor reproducibility.

    Science.gov (United States)

    Nestman, Trenton S; Marshall, Steven D; Qian, Fang; Holton, Nathan; Franciscus, Robert G; Southard, Thomas E

    2011-08-01

    The cervical vertebrae maturation (CVM) method has been advocated as a predictor of peak mandibular growth. A careful review of the literature showed potential methodologic errors that might influence the high reported reproducibility of the CVM method, and we recently established that the reproducibility of the CVM method was poor when these potential errors were eliminated. The purpose of this study was to further investigate the reproducibility of the individual vertebral patterns. In other words, the purpose was to determine which of the individual CVM vertebral patterns could be classified reliably and which could not. Ten practicing orthodontists, trained in the CVM method, evaluated the morphology of cervical vertebrae C2 through C4 from 30 cephalometric radiographs using questions based on the CVM method. The Fleiss kappa statistic was used to assess interobserver agreement when evaluating each cervical vertebrae morphology question for each subject. The Kendall coefficient of concordance was used to assess the level of interobserver agreement when determining a "derived CVM stage" for each subject. Interobserver agreement was high for assessment of the lower borders of C2, C3, and C4 that were either flat or curved in the CVM method, but interobserver agreement was low for assessment of the vertebral bodies of C3 and C4 when they were either trapezoidal, rectangular horizontal, square, or rectangular vertical; this led to the overall poor reproducibility of the CVM method. These findings were reflected in the Fleiss kappa statistic. Furthermore, nearly 30% of the time, individual morphologic criteria could not be combined to generate a final CVM stage because of incompatible responses to the 5 questions. Intraobserver agreement in this study was only 62%, on average, when the inconclusive stagings were excluded as disagreements. Intraobserver agreement was worse (44%) when the inconclusive stagings were included as disagreements. For the group of subjects

  15. Modeling and evaluating repeatability and reproducibility of ordinal classifications

    NARCIS (Netherlands)

    de Mast, J.; van Wieringen, W.N.

    2010-01-01

    This paper argues that currently available methods for the assessment of the repeatability and reproducibility of ordinal classifications are not satisfactory. The paper aims to study whether we can modify a class of models from Item Response Theory, well established for the study of the reliability

  16. Quantitative susceptibility mapping of human brain at 3T: a multisite reproducibility study.

    Science.gov (United States)

    Lin, P-Y; Chao, T-C; Wu, M-L

    2015-03-01

    Quantitative susceptibility mapping of the human brain has demonstrated strong potential in examining iron deposition, which may help in investigating possible brain pathology. This study assesses the reproducibility of quantitative susceptibility mapping across different imaging sites. In this study, the susceptibility values of 5 regions of interest in the human brain were measured on 9 healthy subjects following calibration by using phantom experiments. Each of the subjects was imaged 5 times on 1 scanner with the same procedure repeated on 3 different 3T systems so that both within-site and cross-site quantitative susceptibility mapping precision levels could be assessed. Two quantitative susceptibility mapping algorithms, similar in principle, one by using iterative regularization (iterative quantitative susceptibility mapping) and the other with analytic optimal solutions (deterministic quantitative susceptibility mapping), were implemented, and their performances were compared. Results show that while deterministic quantitative susceptibility mapping had nearly 700 times faster computation speed, residual streaking artifacts seem to be more prominent compared with iterative quantitative susceptibility mapping. With quantitative susceptibility mapping, the putamen, globus pallidus, and caudate nucleus showed smaller imprecision on the order of 0.005 ppm, whereas the red nucleus and substantia nigra, closer to the skull base, had a somewhat larger imprecision of approximately 0.01 ppm. Cross-site errors were not significantly larger than within-site errors. Possible sources of estimation errors are discussed. The reproducibility of quantitative susceptibility mapping in the human brain in vivo is regionally dependent, and the precision levels achieved with quantitative susceptibility mapping should allow longitudinal and multisite studies such as aging-related changes in brain tissue magnetic susceptibility. © 2015 by American Journal of Neuroradiology.

  17. The web-based ASSO-food frequency questionnaire for adolescents: relative and absolute reproducibility assessment.

    Science.gov (United States)

    Filippi, Anna Rita; Amodio, Emanuele; Napoli, Giuseppe; Breda, João; Bianco, Antonino; Jemni, Monèm; Censi, Laura; Mammina, Caterina; Tabacchi, Garden

    2014-12-17

    A new food frequency questionnaire (FFQ) has been recently developed within the Italian Adolescents and Surveillance System for the Obesity prevention (ASSO) Project; it was found to be appropriate for ranking adolescents in food and nutrient levels of intake. The aim of this study was to assess the relative and absolute reproducibility of the ASSO-FFQ for 24 food groups, energy and 52 nutrients. A test-retest study was performed on two ASSO-FFQs administered one month apart of each other to 185 adolescents, aged 14-17 and attending secondary schools in Palermo (Italy). Wilcoxon test assessed differences in median daily intakes between the two FFQs. Agreement was evaluated by quintiles comparison and weighted kappa. Intraclass Correlation Coefficients (ICC) and Bland-Altman method assessed the relative and absolute reliability respectively. Significant difference (p food, water, soft drinks, carbohydrates and sugar. The subjects classified into the same or adjacent quintiles for food groups ranged from 62% (white bread) to 91% (soft drinks); for energy and nutrients from 64% (polyunsaturated fatty acids) to 90% (ethanol). Mean values of weighted kappa were 0.47 and 0.48, respectively for food groups and nutrients. Fair to good ICC values (>0.40) were assessed for thirteen food groups, energy and forty-three nutrients. Limits of Agreement were narrow for almost all food groups and all nutrients. The ASSO-FFQ is a reliable instrument for estimating food groups, energy and nutrients intake in adolescents.

  18. Accuracy, reproducibility, and time efficiency of dental measurements using different technologies.

    Science.gov (United States)

    Grünheid, Thorsten; Patel, Nishant; De Felippe, Nanci L; Wey, Andrew; Gaillard, Philippe R; Larson, Brent E

    2014-02-01

    Historically, orthodontists have taken dental measurements on plaster models. Technological advances now allow orthodontists to take these measurements on digital models. In this study, we aimed to assess the accuracy, reproducibility, and time efficiency of dental measurements taken on 3 types of digital models. emodels (GeoDigm, Falcon Heights, Minn), SureSmile models (OraMetrix, Richardson, Tex), and AnatoModels (Anatomage, San Jose, Calif) were made for 30 patients. Mesiodistal tooth-width measurements taken on these digital models were timed and compared with those on the corresponding plaster models, which were used as the gold standard. Accuracy and reproducibility were assessed using the Bland-Altman method. Differences in time efficiency were tested for statistical significance with 1-way analysis of variance. Measurements on SureSmile models were the most accurate, followed by those on emodels and AnatoModels. Measurements taken on SureSmile models were also the most reproducible. Measurements taken on SureSmile models and emodels were significantly faster than those taken on AnatoModels and plaster models. Tooth-width measurements on digital models can be as accurate as, and might be more reproducible and significantly faster than, those taken on plaster models. Of the models studied, the SureSmile models provided the best combination of accuracy, reproducibility, and time efficiency of measurement. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  19. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis.

    NARCIS (Netherlands)

    Smidt, N.; Windt, A. van der; Assendelft, W.J.; Mourits, A.J.; Devillé, W.L.; Winter, F. de; Bouter, L.M.

    2002-01-01

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of

  20. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis

    NARCIS (Netherlands)

    Smidt, N; van der Windt, DA; Assendelft, WJ; Mourits, AJ; Deville, WL; de Winter, AF; Bouter, LM

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of

  1. Reproducibility of food consumption frequencies derived from the Children's Eating Habits Questionnaire used in the IDEFICS study.

    Science.gov (United States)

    Lanfer, A; Hebestreit, A; Ahrens, W; Krogh, V; Sieri, S; Lissner, L; Eiben, G; Siani, A; Huybrechts, I; Loit, H-M; Papoutsou, S; Kovács, E; Pala, V

    2011-04-01

    To investigate the reproducibility of food consumption frequencies derived from the food frequency section of the Children's Eating Habits Questionnaire (CEHQ-FFQ) that was developed and used in the IDEFICS (Identification and prevention of dietary- and lifestyle-induced health effects in children and infants) project to assess food habits in 2- to 9-year-old European children. From a subsample of 258 children who participated in the IDEFICS baseline examination, parental questionnaires of the CEHQ were collected twice to assess reproducibility of questionnaire results from 0 to 354 days after the first examination. Weighted Cohen's kappa coefficients (κ) and Spearman's correlation coefficients (r) were calculated to assess agreement between the first and second questionnaires for each food item of the CEHQ-FFQ. Stratification was performed for sex, age group, geographical region and length of period between the first and second administrations. Fisher's Z transformation was applied to test correlation coefficients for significant differences between strata. For all food items analysed, weighted Cohen's kappa coefficients (κ) and Spearman's correlation coefficients (r) were significant and positive (P128 days) between the first and second administrations resulted in a generally lower, yet still acceptable, reproducibility. Results indicate that the CEHQ-FFQ gives reproducible estimates of the consumption frequency of 43 food items from 14 food groups in European children.

  2. [Validity and reproducibility of a food frequency questionnaire to assess lipid and phytochemical intake].

    Science.gov (United States)

    Perovic, Nilda R; Defago, Maria D; Aguinaldo, Anabel; Joekes, Silvia; Actis, Adriana B

    2015-01-01

    epidemiological studies have been related food intake with the incidence of non-transmissible chronic diseases. the purpose of the present study was to analyze the validity and reproducibility of a food frequency questionnaire (FFQ) aimed at assessing lipid and phytochemical intake. FFQ was administered to 45 people of both sexes, aged between 20 and 72 years old and resident in Cordoba, Argentina. The FFQ included 257 questions referring to foods, their consumption frequency and portion size. Regarding consumption of fruit and vegetables, the season was also taken into account. The questionnaire was applied at two different periods (FFQ1 and FFQ2) with a break of six months in between. As a reference, the 24-hour dietary recall was used (24HDR) three times. The mid intake of FFQ1-FFQ2, the 24HDR-FFQ2 median intake, median difference, Mean Absolute Deviation from the median differences (MAD), Wilcoxon signed rank sum test and Spearman rank order correlation coefficients were calculated to analyze the accuracy of the FFQ data. the correlation coefficients for FFQ1-FFQ2 varied from 0.52 for 20:5 n3 eicosapentanoic (EPA) fatty acid to 0.89 for 4:0 butyric fatty acid (p<0.05). For 24HDR-FFQ2, the values ranged from 0.19 for lycopene to 0.93 for EPA fatty acid (p<0.05). the analysis carried out showed an acceptable validity and reproducibility of the FFQ, thus enabling it to be used in research relating the intake of lipids and phytochemicals and the risk of non-transmissible diseases.

  3. Potency Evaluation of Recombinant Human Erythropoietin in Brazil: Assessment of Reproducibility Using a Practical Approach

    Directory of Open Access Journals (Sweden)

    Michele Cardoso do Nascimento

    2015-08-01

    Full Text Available In this study, we compared the results of potency determination of recombinant human erythropoietin (rhEPO obtained between 2010 and 2012 by the National Institute of Quality Control in Health (INCQS/Fiocruz, i.e., the National Control Laboratory (NCL, and by a manufacturer of rhEPO. In total, 47 different batches of commercially prepared rhEPO (alpha isoform were analyzed. All results, including those of the control and warning limits, remained within the limits recommended by European Pharmacopoeia (Ph. Eur.. All relative error (RE values were less than ± 30%, wh ereas most were approximately ± 20%. Applying the Bland-Altman plot, only two of 47 values remained outside the limits of agreement (LA. In addition, agreement of potency determination between INCQS and the manufacturer coefficient of variation of reproducibility (% CVR was considered satisfactory. Taken together, our results demonstrate (i. the potency assay of rhEPO performed at INCQS, is standardized and controlled, (ii. the comparison of our results with those of the manufacturer, revealed an adequate inter-laboratory variation, and (iii. the critical appraisal proposed here appears to be a feasible tool to assess the reproducibility of biological activity, providing additional information regarding monitoring and production consistency to manufacturers and NCLs.

  4. Reproducibility of the results in ultrasonic testing

    International Nuclear Information System (INIS)

    Chalaye, M.; Launay, J.P.; Thomas, A.

    1980-12-01

    This memorandum reports on the conclusions of the tests carried out in order to evaluate the reproducibility of ultrasonic tests made on welded joints. FRAMATOME have started a study to assess the dispersion of results afforded by the test line and to characterize its behaviour. The tests covered sensors and ultrasonic generators said to be identical to each other (same commercial batch) [fr

  5. Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual.

    Science.gov (United States)

    Dang, Natasha Radhika; Moreau, Marc J; Hill, Douglas L; Mahood, James K; Raso, James

    2005-05-01

    Retrospective cross-sectional assessment of the reproducibility and reliability of radiographic parameters. To measure the intra-examiner and interexaminer reproducibility and reliability of salient radiographic features. The management and treatment of adolescent idiopathic scoliosis (AIS) depends on accurate and reproducible radiographic measurements of the deformity. Ten sets of radiographs were randomly selected from a sample of patients with AIS, with initial curves between 20 degrees and 45 degrees. Fourteen measures of the deformity were measured from posteroanterior and lateral radiographs by 2 examiners, and were repeated 5 times at intervals of 3-5 days. Intra-examiner and interexaminer differences were examined. The parameters include measures of curve size, spinal imbalance, sagittal kyphosis and alignment, maximum apical vertebral rotation, T1 tilt, spondylolysis/spondylolisthesis, and skeletal age. Intra-examiner reproducibility was generally excellent for parameters measured from the posteroanterior radiographs but only fair to good for parameters from the lateral radiographs, in which some landmarks were not clearly visible. Of the 13 parameters observed, 7 had excellent interobserver reliability. The measurements from the lateral radiograph were less reproducible and reliable and, thus, may not add value to the assessment of AIS. Taking additional measures encourages a systematic and comprehensive assessment of spinal radiographs.

  6. Reproducibility of the assessment of myocardial function using gated Tc-99m-MIBI SPECT and quantitative software

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Cheon, Gi Jeong; Ahn, Ji Young; Jeong, Joon Ki; Lee, Myung Chul

    1998-01-01

    We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT. We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/-42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml+/-39 ml), and EF from 20% to 68% (51%+/-14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect

  7. Reproducibility and relative validity of a brief quantitative food frequency questionnaire for assessing fruit and vegetable intakes in North-African women.

    Science.gov (United States)

    Landais, E; Gartner, A; Bour, A; McCullough, F; Delpeuch, F; Holdsworth, M

    2014-04-01

    In the context of a rapidly increasing prevalence of noncommunicable diseases, fruit and vegetables could play a key preventive role. To date, there is no rapid assessment tool available for measuring the fruit and vegetable intakes of North-African women. The present study aimed to investigate the reproducibility and relative validity of an eight-item quantitative food frequency questionnaire that measures the fruit and vegetable intakes (FV-FFQ) of Moroccan women. During a 1-week period, 100 women, living in the city of Rabat, Morocco (aged 20-49 years) completed the short FV-FFQ twice: once at baseline (FV-FFQ1) and once at the end of the study (FV-FFQ2). In the mean time, participants completed three 24-h dietary recalls. All questionnaires were administered by interviewers. Reproducibility was assessed by computing Spearman's correlation coefficients, intraclass correlation (ICC) coefficients and kappa statistics. Relative validity was assessed by computing Wilcoxon signed-rank tests and Spearman's correlation coefficients, as well as by performing Bland-Altman plots. In terms of reproducibility, Spearman's correlation coefficient was 0.56; ICC coefficient was 0.68; and weighted kappa was 0.35. In terms of relative validity, compared with the three 24-h recalls, the FV-FFQ slightly underestimated mean fruit and vegetable intakes (-10.9%; P = 0.006); Spearman's correlation coefficient was 0.69; at the individual level, intakes measured by the FV-FFQ were between 0.39 and 2.19 times those measured by the 24-h recalls. The brief eight-item FV-FFQ is a reliable and relatively valid tool for measuring mean fruit and vegetable intakes at the population level, although this is not the case at the individual level. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  8. Transvaginal ultrasound assessment of myometrial and cervical stroma invasion in women with endometrial cancer -interobserver reproducibility among ultrasound experts and gynaecologists

    DEFF Research Database (Denmark)

    Eriksson, LS; Lindqvist, PG; Flöter Rådestad, A

    2014-01-01

    OBJECTIVES: To assess interobserver reproducibility among ultrasound experts and gynaecologists in the prediction of deep myometrial- and cervical stroma invasion by transvaginal ultrasound in women with endometrial cancer. METHODS: Video-clips of the corpus- and cervix uteri of 53 women...... with endometrial cancer, examined preoperatively by the same ultrasound expert, were integrated in a digitalized survey. Nine ultrasound experts and 9 gynaecologists evaluated presence or absence of deep myometrial- and cervical stroma invasion. Histopathology from hysterectomy specimen was used as gold standard.......001). CONCLUSION: Preoperative ultrasound assessment of deep myometrial- and cervical stroma invasion in endometrial cancer is best performed by ultrasound experts, as they show a higher degree of agreement to histopathology and higher interobserver reproducibility in the assessment of cervical stromal invasion....

  9. Contextual sensitivity in scientific reproducibility

    Science.gov (United States)

    Van Bavel, Jay J.; Mende-Siedlecki, Peter; Brady, William J.; Reinero, Diego A.

    2016-01-01

    In recent years, scientists have paid increasing attention to reproducibility. For example, the Reproducibility Project, a large-scale replication attempt of 100 studies published in top psychology journals found that only 39% could be unambiguously reproduced. There is a growing consensus among scientists that the lack of reproducibility in psychology and other fields stems from various methodological factors, including low statistical power, researcher’s degrees of freedom, and an emphasis on publishing surprising positive results. However, there is a contentious debate about the extent to which failures to reproduce certain results might also reflect contextual differences (often termed “hidden moderators”) between the original research and the replication attempt. Although psychologists have found extensive evidence that contextual factors alter behavior, some have argued that context is unlikely to influence the results of direct replications precisely because these studies use the same methods as those used in the original research. To help resolve this debate, we recoded the 100 original studies from the Reproducibility Project on the extent to which the research topic of each study was contextually sensitive. Results suggested that the contextual sensitivity of the research topic was associated with replication success, even after statistically adjusting for several methodological characteristics (e.g., statistical power, effect size). The association between contextual sensitivity and replication success did not differ across psychological subdisciplines. These results suggest that researchers, replicators, and consumers should be mindful of contextual factors that might influence a psychological process. We offer several guidelines for dealing with contextual sensitivity in reproducibility. PMID:27217556

  10. Contextual sensitivity in scientific reproducibility.

    Science.gov (United States)

    Van Bavel, Jay J; Mende-Siedlecki, Peter; Brady, William J; Reinero, Diego A

    2016-06-07

    In recent years, scientists have paid increasing attention to reproducibility. For example, the Reproducibility Project, a large-scale replication attempt of 100 studies published in top psychology journals found that only 39% could be unambiguously reproduced. There is a growing consensus among scientists that the lack of reproducibility in psychology and other fields stems from various methodological factors, including low statistical power, researcher's degrees of freedom, and an emphasis on publishing surprising positive results. However, there is a contentious debate about the extent to which failures to reproduce certain results might also reflect contextual differences (often termed "hidden moderators") between the original research and the replication attempt. Although psychologists have found extensive evidence that contextual factors alter behavior, some have argued that context is unlikely to influence the results of direct replications precisely because these studies use the same methods as those used in the original research. To help resolve this debate, we recoded the 100 original studies from the Reproducibility Project on the extent to which the research topic of each study was contextually sensitive. Results suggested that the contextual sensitivity of the research topic was associated with replication success, even after statistically adjusting for several methodological characteristics (e.g., statistical power, effect size). The association between contextual sensitivity and replication success did not differ across psychological subdisciplines. These results suggest that researchers, replicators, and consumers should be mindful of contextual factors that might influence a psychological process. We offer several guidelines for dealing with contextual sensitivity in reproducibility.

  11. Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study.

    Science.gov (United States)

    Engelberger, Rolf P; Blazek, Claudia; Amsler, Felix; Keo, Hong H; Baumann, Frédéric; Blättler, Werner; Baumgartner, Iris; Willenberg, Torsten

    2011-10-05

    Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P correction formula permitted further improvement of CVW. Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.

  12. Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study

    Directory of Open Access Journals (Sweden)

    Baumgartner Iris

    2011-10-01

    Full Text Available Abstract Background Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Methods Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD and whole limb (limbBF volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW, and as intra-class correlation coefficients (ICC. Results A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both. At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58% for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79% for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P W. Conclusions Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.

  13. [The influence of printing technology conditions on the accuracy and reproducibility of printed contrast panels for assessing contrast sensitivity].

    Science.gov (United States)

    Raabe, T; Jung, U; Wilhelm, H

    2014-08-01

    Contrast studies can provide important knowledge for treatment decisions before surgery or for assessing the driving ability of professional drivers. Accordingly, high demands are placed on contrast panels to obtain reliable and reproducible results. The aim of the study is to find out if the contrast panels on the market meet the requirements. On the basis of measurement evaluation and schematic presentations potential sources of error can be identified. These sources of error may have a decisive influence on the assessment of contrast vision. Far-reaching analyses have shown that three parameters can have a significant influence on the accuracy and reproducibility of printed contrast panels. This holds for certain properties of the printing substrate, the type of representation of display element, and the choice of the colourant. Only the correct interaction between the substrate and the print colour effects an angle-independent contrast. A matt substrate is necessary, which has a low difference to the printed contrast element in respect of glow, so that possible angle differences have no influence on the contrast assessment. The contrast elements of a contrast panel vary in brightness. Conventional methods for typographical representation of different brightnesses use the method of screening. This causes undesirable edges, which weaken in particular the lower-contrast elements unintentionally. Use of special colours can avoid this effect. In the visible wavelength range the studied contrast elements have an irregular absorption behaviour. Because of differences between the lighting surroundings, this can lead to a differentiated stimulation of cones in practice. Appropriate colourants have a constant absorption behaviour. To get representative results of contrast studies the production of contrast panels needs more knowledge about the interaction between paper and colour than is typically required for print products. On the basis of a prototype optimisation

  14. Superior Reproducibility of the Leading to Leading Edge and Inner to Inner Edge Methods in the Ultrasound Assessment of Maximum Abdominal Aortic Diameter.

    Science.gov (United States)

    Borgbjerg, Jens; Bøgsted, Martin; Lindholt, Jes S; Behr-Rasmussen, Carsten; Hørlyck, Arne; Frøkjær, Jens B

    2018-02-01

    Controversy exists regarding optimal caliper placement in ultrasound assessment of maximum abdominal aortic diameter. This study aimed primarily to determine reproducibility of caliper placement in relation to the aortic wall with the three principal methods: leading to leading edge (LTL), inner to inner edge (ITI), and outer to outer edge (OTO). The secondary aim was to assess the mean difference between the OTO, ITI, and LTL diameters and estimate the impact of using either of these methods on abdominal aortic aneurysm (AAA) prevalence in a screening program. Radiologists (n=18) assessed the maximum antero-posterior abdominal aortic diameter by completing repeated caliper placements with the OTO, LTL, and ITI methods on 50 still abdominal aortic images obtained from an AAA screening program. Inter-observer reproducibility was calculated as the limit of agreement with the mean (LoA), which represents expected deviation of a single observer from the mean of all observers. Intra-observer reproducibility was assessed averaging the LoA for each observer with their repeated measurements. Based on data from an AAA screening trial and the estimated mean differences between the three principal methods, AAA prevalence was estimated using each of the methods. The inter-observer LoA of the OTO, ITI, and LTL was 2.6, 1.9, and 1.9 mm, whereas the intra-observer LoA was 2.0, 1.6, and 1.5 mm, respectively. Mean differences of 5.0 mm were found between OTO and ITI measurements, 2.6 mm between OTO and LTL measurements, and 2.4 mm between LTL and ITI measurements. The prevalence of AAA almost doubled using OTO instead of ITI, while the difference between ITI and LTL was minor (3.3% vs. 4.0% AAA). The study shows superior reproducibility of LTL and ITI compared with the OTO method of caliper placement in ultrasound determination of maximum abdominal aortic diameter, and the choice of caliper placement method significantly affects the prevalence of AAAs in screening programs

  15. Using prediction markets to estimate the reproducibility of scientific research

    Science.gov (United States)

    Dreber, Anna; Pfeiffer, Thomas; Almenberg, Johan; Isaksson, Siri; Wilson, Brad; Chen, Yiling; Nosek, Brian A.; Johannesson, Magnus

    2015-01-01

    Concerns about a lack of reproducibility of statistically significant results have recently been raised in many fields, and it has been argued that this lack comes at substantial economic costs. We here report the results from prediction markets set up to quantify the reproducibility of 44 studies published in prominent psychology journals and replicated in the Reproducibility Project: Psychology. The prediction markets predict the outcomes of the replications well and outperform a survey of market participants’ individual forecasts. This shows that prediction markets are a promising tool for assessing the reproducibility of published scientific results. The prediction markets also allow us to estimate probabilities for the hypotheses being true at different testing stages, which provides valuable information regarding the temporal dynamics of scientific discovery. We find that the hypotheses being tested in psychology typically have low prior probabilities of being true (median, 9%) and that a “statistically significant” finding needs to be confirmed in a well-powered replication to have a high probability of being true. We argue that prediction markets could be used to obtain speedy information about reproducibility at low cost and could potentially even be used to determine which studies to replicate to optimally allocate limited resources into replications. PMID:26553988

  16. Using prediction markets to estimate the reproducibility of scientific research.

    Science.gov (United States)

    Dreber, Anna; Pfeiffer, Thomas; Almenberg, Johan; Isaksson, Siri; Wilson, Brad; Chen, Yiling; Nosek, Brian A; Johannesson, Magnus

    2015-12-15

    Concerns about a lack of reproducibility of statistically significant results have recently been raised in many fields, and it has been argued that this lack comes at substantial economic costs. We here report the results from prediction markets set up to quantify the reproducibility of 44 studies published in prominent psychology journals and replicated in the Reproducibility Project: Psychology. The prediction markets predict the outcomes of the replications well and outperform a survey of market participants' individual forecasts. This shows that prediction markets are a promising tool for assessing the reproducibility of published scientific results. The prediction markets also allow us to estimate probabilities for the hypotheses being true at different testing stages, which provides valuable information regarding the temporal dynamics of scientific discovery. We find that the hypotheses being tested in psychology typically have low prior probabilities of being true (median, 9%) and that a "statistically significant" finding needs to be confirmed in a well-powered replication to have a high probability of being true. We argue that prediction markets could be used to obtain speedy information about reproducibility at low cost and could potentially even be used to determine which studies to replicate to optimally allocate limited resources into replications.

  17. Assessment of intercentre reproducibility and epidemiological concordance of Legionella pneumophila serogroup 1 genotyping by amplified fragment length polymorphism analysis

    DEFF Research Database (Denmark)

    Fry, N K; Bangsborg, Jette Marie; Bernander, S

    2000-01-01

    The aims of this work were to assess (i) the intercentre reproducibility and epidemiological concordance of amplified fragment length polymorphism analysis for epidemiological typing of Legionella pneumophila serogroup 1, and (ii) the suitability of the method for standardisation and implementation...... by members of the European Working Group on Legionella Infections. Fifty coded isolates comprising two panels of well-characterised strains, a "reproducibility" panel (n=20) and an "epidemiologically related" panel (n=30), were sent to 13 centres in 12 European countries. Analysis was undertaken in each...... using gel analysis software yielded R=1.00 and E=1.00, with 12, 13 or 14 types. This method can be used as a simple, rapid screening tool for epidemiological typing of isolates of Legionella pneumophila serogroup 1. Results demonstrate that the method can be highly reproducible (R=1...

  18. Reproducibility and validity of the Shanghai Women's Health Study physical activity questionnaire.

    Science.gov (United States)

    Matthews, Charles E; Shu, Xiao-Ou; Yang, Gong; Jin, Fan; Ainsworth, Barbara E; Liu, Dake; Gao, Yu-Tang; Zheng, Wei

    2003-12-01

    In this investigation, the authors evaluated the reproducibility and validity of the Shanghai Women's Health Study (SWHS) physical activity questionnaire (PAQ), which was administered in a cohort study of approximately 75,000 Chinese women aged 40-70 years. Reproducibility (2-year test-retest) was evaluated using kappa statistics and intraclass correlation coefficients (ICCs). Validity was evaluated by comparing Spearman correlations (r) for the SWHS PAQ with two criterion measures administered over a period of 12 months: four 7-day physical activity logs and up to 28 7-day PAQs. Women were recruited from the SWHS cohort (n = 200). Results indicated that the reproducibility of adolescent and adult exercise participation (kappa = 0.85 and kappa = 0.64, respectively) and years of adolescent exercise and adult exercise energy expenditure (ICC = 0.83 and ICC = 0.70, respectively) was reasonable. Reproducibility values for adult lifestyle activities were lower (ICC = 0.14-0.54). Significant correlations between the PAQ and criterion measures of adult exercise were observed for the first PAQ administration (physical activity log, r = 0.50; 7-day PAQ, r = 0.62) and the second PAQ administration (physical activity log, r = 0.74; 7-day PAQ, r = 0.80). Significant correlations between PAQ lifestyle activities and the 7-day PAQ were also noted (r = 0.33-0.88). These data indicate that the SWHS PAQ is a reproducible and valid measure of exercise behaviors and that it demonstrates utility in stratifying women by levels of important lifestyle activities (e.g., housework, walking, cycling).

  19. Reproducibility of task activation using the Addenbrooke's cognitive examination in healthy controls: A functional Transcranial Doppler ultrasonography study.

    Science.gov (United States)

    Beishon, L; Williams, C A L; Panerai, R B; Robinson, T G; Haunton, V J

    2017-11-01

    Cerebral blood flow velocity (CBFv) changes occurring with cognitive stimulation can be measured by Transcranial Doppler ultrasonography (TCD). The aim of this study was to assess the reproducibility of CBFv changes to the Addenbrooke's cognitive examination (ACE-III). 13 volunteers underwent bilateral TCD (middle cerebral artery), continuous heart rate (HR, 3-lead ECG, Finometer), beat-to-beat mean arterial pressure (MAP, Finometer), and end-tidal CO 2 (ETCO 2 , capnography). After 5min baseline, all ACE-III tasks were performed in 3 domains (A/B/C). Data presented are population CBFv peak normalised changes and area under the curve (AUC). Statistical analysis was by 2-way repeated measures (ANOVA), intra-class correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV). 12 bilateral data sets were obtained (10 right hand dominant, 6 female). Baseline parameters (MAP, HR, ETCO 2 ) did not differ between visits. All tasks increased CBFv. Only domain A on AUC analysis differed significantly on ANOVA, and one task on post hoc testing (p examine reproducibility of CBFv changes to a complete cognitive assessment tool. Reproducibility of CBFv measurements to the ACE-III was variable. AUC may provide more reliable estimates than peak CBFv responses. These data need validating in patient populations. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Reproducibility of preclinical animal research improves with heterogeneity of study samples

    Science.gov (United States)

    Vogt, Lucile; Sena, Emily S.; Würbel, Hanno

    2018-01-01

    Single-laboratory studies conducted under highly standardized conditions are the gold standard in preclinical animal research. Using simulations based on 440 preclinical studies across 13 different interventions in animal models of stroke, myocardial infarction, and breast cancer, we compared the accuracy of effect size estimates between single-laboratory and multi-laboratory study designs. Single-laboratory studies generally failed to predict effect size accurately, and larger sample sizes rendered effect size estimates even less accurate. By contrast, multi-laboratory designs including as few as 2 to 4 laboratories increased coverage probability by up to 42 percentage points without a need for larger sample sizes. These findings demonstrate that within-study standardization is a major cause of poor reproducibility. More representative study samples are required to improve the external validity and reproducibility of preclinical animal research and to prevent wasting animals and resources for inconclusive research. PMID:29470495

  1. Repeatability and reproducibility of decisions by latent fingerprint examiners.

    Directory of Open Access Journals (Sweden)

    Bradford T Ulery

    Full Text Available The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. We tested latent print examiners on the extent to which they reached consistent decisions. This study assessed intra-examiner repeatability by retesting 72 examiners on comparisons of latent and exemplar fingerprints, after an interval of approximately seven months; each examiner was reassigned 25 image pairs for comparison, out of total pool of 744 image pairs. We compare these repeatability results with reproducibility (inter-examiner results derived from our previous study. Examiners repeated 89.1% of their individualization decisions, and 90.1% of their exclusion decisions; most of the changed decisions resulted in inconclusive decisions. Repeatability of comparison decisions (individualization, exclusion, inconclusive was 90.0% for mated pairs, and 85.9% for nonmated pairs. Repeatability and reproducibility were notably lower for comparisons assessed by the examiners as "difficult" than for "easy" or "moderate" comparisons, indicating that examiners' assessments of difficulty may be useful for quality assurance. No false positive errors were repeated (n = 4; 30% of false negative errors were repeated. One percent of latent value decisions were completely reversed (no value even for exclusion vs. of value for individualization. Most of the inter- and intra-examiner variability concerned whether the examiners considered the information available to be sufficient to reach a conclusion; this variability was concentrated on specific image pairs such that repeatability and reproducibility were very high on some comparisons and very low on others. Much of the variability appears to be due to making categorical decisions in borderline cases.

  2. Reproducibility in Natural Language Processing: A Case Study of Two R Libraries for Mining PubMed/MEDLINE

    Science.gov (United States)

    Cohen, K. Bretonnel; Xia, Jingbo; Roeder, Christophe; Hunter, Lawrence E.

    2018-01-01

    There is currently a crisis in science related to highly publicized failures to reproduce large numbers of published studies. The current work proposes, by way of case studies, a methodology for moving the study of reproducibility in computational work to a full stage beyond that of earlier work. Specifically, it presents a case study in attempting to reproduce the reports of two R libraries for doing text mining of the PubMed/MEDLINE repository of scientific publications. The main findings are that a rational paradigm for reproduction of natural language processing papers can be established; the advertised functionality was difficult, but not impossible, to reproduce; and reproducibility studies can produce additional insights into the functioning of the published system. Additionally, the work on reproducibility lead to the production of novel user-centered documentation that has been accessed 260 times since its publication—an average of once a day per library. PMID:29568821

  3. Pulsatility of Lenticulostriate Arteries Assessed by 7 Tesla Flow MRI-Measurement, Reproducibility, and Applicability to Aging Effect.

    Science.gov (United States)

    Schnerr, Roald S; Jansen, Jacobus F A; Uludag, Kamil; Hofman, Paul A M; Wildberger, Joachim E; van Oostenbrugge, Robert J; Backes, Walter H

    2017-01-01

    Characterization of flow properties in cerebral arteries with 1.5 and 3 Tesla MRI is usually limited to large cerebral arteries and difficult to evaluate in the small perforating arteries due to insufficient spatial resolution. In this study, we assessed the feasibility to measure blood flow waveforms in the small lenticulostriate arteries with 7 Tesla velocity-sensitive MRI. The middle cerebral artery was included as reference. Imaging was performed in five young and five old healthy volunteers. Flow was calculated by integrating time-varying velocity values over the vascular cross-section. MRI acquisitions were performed twice in each subject to determine reproducibility. From the flow waveforms, the pulsatility index and damping factor were deduced. Reproducibility values, in terms of the intraclass correlation coefficients, were found to be good to excellent. Measured pulsatility index of the lenticulostriate arteries significantly increased and damping factor significantly decreased with age. In conclusion, we demonstrate that blood flow through the lenticostriate arteries can be precisely measured using 7 Tesla MRI and reveal effects of arterial stiffness due to aging. These findings hold promise to provide relevant insights into the pathologies involving perforating cerebral arteries.

  4. OECD validation study to assess intra- and inter-laboratory reproducibility of the zebrafish embryo toxicity test for acute aquatic toxicity testing

    NARCIS (Netherlands)

    Busquet, F.; Strecker, R.; Rawlings, J.M.; Belanger, S.E.; Braunbeck, T.; Carr, G.J.; Cenijn, P.H.; Fochtman, P.; Gourmelon, A.; Hübler, N.; Kleensang, A.; Knöbel, M.; Kussatz, C.; Legler, J.; Lillicrap, A.; Martínez-Jerónimo, F.; Polleichtner, C.; Rzodeczko, H.; Salinas, E.; Schneider, K.E.; Scholz, S.; van den Brandhof, E.J.; van der Ven, L.T.; Walter-Rohde, S.; Weigt, S.; Witters, H.; Halder, M.

    2014-01-01

    A The OECD validation study of the zebrafish embryo acute toxicity test (ZFET) for acute aquatic toxicity testing evaluated the ZFET reproducibility by testing 20 chemicals at 5 different concentrations in 3 independent runs in at least 3 laboratories. Stock solutions and test concentrations were

  5. Within-person reproducibility of urinary bisphenol A and phthalate metabolites over a 1 to 3 year period among women in the Nurses’ Health Studies: a prospective cohort study

    Science.gov (United States)

    2013-01-01

    Background Associations of bisphenol A and phthalates with chronic disease health outcomes are increasingly being investigated in epidemiologic studies. The majority of previous studies of within-person variability in urinary bisphenol A and phthalate metabolite concentrations have focused on reproducibility over short time periods. Long-term reproducibility data are needed to assess the potential usefulness of these biomarkers for prospective studies, particularly those examining risk of diseases with long latency periods. Low within-person reproducibility may attenuate relative risk estimates and reduce statistical power to detect associations with disease. Therefore, we assessed within-person reproducibility of bisphenol A, eight phthalate metabolites, and phthalic acid in spot urine samples over 1 to 3 years among women enrolled in two large cohort studies. Methods Women in the Nurses’ Health Study and Nurses’ Health Study II provided two spot urine samples, 1 to 3 years apart (n = 80 women for analyses of bisphenol A; n = 40 women for analyses of phthalate metabolites; n = 34 women for analyses of phthalic acid). To measure within-person reproducibility, we calculated Spearman rank correlation coefficients and intraclass correlation coefficients for creatinine-adjusted concentrations of bisphenol A, phthalate metabolites, and phthalic acid. Results Over 1 to 3 years, within-person variability of bisphenol A was high relative to total variability (intraclass correlation coefficient = 0.14) and rankings of bisphenol A levels between time-points were weakly correlated (Spearman correlation = 0.19). Seven of the eight phthalate metabolites and phthalic acid demonstrated moderate within-person stability over time (Spearman correlation or intraclass correlation coefficient = 0.39-0.55). Restricting analyses to first-morning urine samples did not alter results. Conclusions Single measurements of bisphenol A in spot urine samples were

  6. Within-person reproducibility of urinary bisphenol A and phthalate metabolites over a 1 to 3 year period among women in the Nurses' Health Studies: a prospective cohort study.

    Science.gov (United States)

    Townsend, Mary K; Franke, Adrian A; Li, Xingnan; Hu, Frank B; Eliassen, A Heather

    2013-09-13

    Associations of bisphenol A and phthalates with chronic disease health outcomes are increasingly being investigated in epidemiologic studies. The majority of previous studies of within-person variability in urinary bisphenol A and phthalate metabolite concentrations have focused on reproducibility over short time periods. Long-term reproducibility data are needed to assess the potential usefulness of these biomarkers for prospective studies, particularly those examining risk of diseases with long latency periods. Low within-person reproducibility may attenuate relative risk estimates and reduce statistical power to detect associations with disease. Therefore, we assessed within-person reproducibility of bisphenol A, eight phthalate metabolites, and phthalic acid in spot urine samples over 1 to 3 years among women enrolled in two large cohort studies. Women in the Nurses' Health Study and Nurses' Health Study II provided two spot urine samples, 1 to 3 years apart (n = 80 women for analyses of bisphenol A; n = 40 women for analyses of phthalate metabolites; n = 34 women for analyses of phthalic acid). To measure within-person reproducibility, we calculated Spearman rank correlation coefficients and intraclass correlation coefficients for creatinine-adjusted concentrations of bisphenol A, phthalate metabolites, and phthalic acid. Over 1 to 3 years, within-person variability of bisphenol A was high relative to total variability (intraclass correlation coefficient = 0.14) and rankings of bisphenol A levels between time-points were weakly correlated (Spearman correlation = 0.19). Seven of the eight phthalate metabolites and phthalic acid demonstrated moderate within-person stability over time (Spearman correlation or intraclass correlation coefficient = 0.39-0.55). Restricting analyses to first-morning urine samples did not alter results. Single measurements of bisphenol A in spot urine samples were highly variable within women over 1 to 3

  7. Hippocampal volume change measurement: quantitative assessment of the reproducibility of expert manual outlining and the automated methods FreeSurfer and FIRST.

    Science.gov (United States)

    Mulder, Emma R; de Jong, Remko A; Knol, Dirk L; van Schijndel, Ronald A; Cover, Keith S; Visser, Pieter J; Barkhof, Frederik; Vrenken, Hugo

    2014-05-15

    To measure hippocampal volume change in Alzheimer's disease (AD) or mild cognitive impairment (MCI), expert manual delineation is often used because of its supposed accuracy. It has been suggested that expert outlining yields poorer reproducibility as compared to automated methods, but this has not been investigated. To determine the reproducibilities of expert manual outlining and two common automated methods for measuring hippocampal atrophy rates in healthy aging, MCI and AD. From the Alzheimer's Disease Neuroimaging Initiative (ADNI), 80 subjects were selected: 20 patients with AD, 40 patients with mild cognitive impairment (MCI) and 20 healthy controls (HCs). Left and right hippocampal volume change between baseline and month-12 visit was assessed by using expert manual delineation, and by the automated software packages FreeSurfer (longitudinal processing stream) and FIRST. To assess reproducibility of the measured hippocampal volume change, both back-to-back (BTB) MPRAGE scans available for each visit were analyzed. Hippocampal volume change was expressed in μL, and as a percentage of baseline volume. Reproducibility of the 1-year hippocampal volume change was estimated from the BTB measurements by using linear mixed model to calculate the limits of agreement (LoA) of each method, reflecting its measurement uncertainty. Using the delta method, approximate p-values were calculated for the pairwise comparisons between methods. Statistical analyses were performed both with inclusion and exclusion of visibly incorrect segmentations. Visibly incorrect automated segmentation in either one or both scans of a longitudinal scan pair occurred in 7.5% of the hippocampi for FreeSurfer and in 6.9% of the hippocampi for FIRST. After excluding these failed cases, reproducibility analysis for 1-year percentage volume change yielded LoA of ±7.2% for FreeSurfer, ±9.7% for expert manual delineation, and ±10.0% for FIRST. Methods ranked the same for reproducibility of 1

  8. Inter-Scan Reproducibility of Carotid Plaque Volume Measurements by 3-D Ultrasound

    DEFF Research Database (Denmark)

    Sandholt, Benjamin V; Collet-Billon, Antoine; Entrekin, Robert

    2018-01-01

    (PPV) measure centered on MPT. Total plaque volume (TPV), PPV from a 10-mm segment and MPT were measured using dedicated semi-automated software on 38 plaques from 26 patients. Inter-scan reproducibility was assessed using the t-test, Bland-Altman plots and Pearson's correlation coefficient....... There was a mean difference of 0.01 mm in MPT (limits of agreement: -0.45 to 0.42 mm, Pearson's correlation coefficient: 0.96). Both volume measurements exhibited high reproducibility, with PPV being superior (limits of agreement: -35.3 mm3to 33.5 mm3, Pearson's correlation coefficient: 0.96) to TPV (limits...... of agreement: -88.2 to 61.5 mm3, Pearson's correlation coefficient: 0.91). The good reproducibility revealed by the present results encourages future studies on establishing plaque quantification as part of cardiovascular risk assessment and for follow-up of disease progression over time....

  9. Scan-rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers.

    Science.gov (United States)

    van der Palen, Roel L F; Roest, Arno A W; van den Boogaard, Pieter J; de Roos, Albert; Blom, Nico A; Westenberg, Jos J M

    2018-05-26

    The aim was to investigate scan-rescan reproducibility and observer variability of segmental aortic 3D systolic wall shear stress (WSS) by phase-specific segmentation with 4D flow MRI in healthy volunteers. Ten healthy volunteers (age 26.5 ± 2.6 years) underwent aortic 4D flow MRI twice. Maximum 3D systolic WSS (WSSmax) and mean 3D systolic WSS (WSSmean) for five thoracic aortic segments over five systolic cardiac phases by phase-specific segmentations were calculated. Scan-rescan analysis and observer reproducibility analysis were performed. Scan-rescan data showed overall good reproducibility for WSSmean (coefficient of variation, COV 10-15%) with moderate-to-strong intraclass correlation coefficient (ICC 0.63-0.89). The variability in WSSmax was high (COV 16-31%) with moderate-to-good ICC (0.55-0.79) for different aortic segments. Intra- and interobserver reproducibility was good-to-excellent for regional aortic WSSmax (ICC ≥ 0.78; COV ≤ 17%) and strong-to-excellent for WSSmean (ICC ≥ 0.86; COV ≤ 11%). In general, ascending aortic segments showed more WSSmax/WSSmean variability compared to aortic arch or descending aortic segments for scan-rescan, intraobserver and interobserver comparison. Scan-rescan reproducibility was good for WSSmean and moderate for WSSmax for all thoracic aortic segments over multiple systolic phases in healthy volunteers. Intra/interobserver reproducibility for segmental WSS assessment was good-to-excellent. Variability of WSSmax is higher and should be taken into account in case of individual follow-up or in comparative rest-stress studies to avoid misinterpretation.

  10. Reproducibility in the analysis of multigated radionuclide studies of left ventricular ejection fraction

    International Nuclear Information System (INIS)

    Gjorup, T.; Kelbaek, H.; Vestergaard, B.; Fogh, J.; Munck, O.; Jensen, A.M.

    1989-01-01

    The authors determined the reproducibility (the standard deviation [SD]) in the analysis of multigated radionuclide studies of left ventricular ejection fraction (LVEF). Radionuclide studies from a consecutive series of 38 patients suspected of ischemic heart disease were analyzed independently by four nuclear medicine physiologists and four laboratory technicians. Each study was analyzed three times by each of the observers. Based on the analyses of the eight observers, the SD could be estimated by the use of a variance component model for LVEF determinations calculated as the average of the analyses of an arbitrary number of observers making an arbitrary number of analyses. This study presents the SDs for LVEF determinations based on the analyses of one to five observers making one to five analyses each. The SD of a LVEF determination decreased from 3.96% to 2.98% when an observer increased his number of analyses from one to five. A more pronounced decrease in the SD from 3.96% to 1.77% was obtained when the LVEF determinations were based on the average of a single analysis made by one to five observers. However, when dealing with the difference between LVEF determinations from two studies, the highest reproducibility was obtained if the LVEF determinations at both studies were based on the analyses made by the same observer. No significant difference was found in the reproducibility of analyses made by nuclear medicine physicians and laboratory technicians. Our study revealed that to increase the reproducibility of LVEF determinations, special efforts should be made to standardize the outlining of the end-systolic region interest

  11. Reproducibility of a reaming test

    DEFF Research Database (Denmark)

    Pilny, Lukas; Müller, Pavel; De Chiffre, Leonardo

    2012-01-01

    The reproducibility of a reaming test was analysed to document its applicability as a performance test for cutting fluids. Reaming tests were carried out on a drilling machine using HSS reamers. Workpiece material was an austenitic stainless steel, machined using 4.75 m∙min-1 cutting speed and 0......). Process reproducibility was assessed as the ability of different operators to ensure a consistent rating of individual lubricants. Absolute average values as well as experimental standard deviations of the evaluation parameters were calculated, and uncertainty budgeting was performed. Results document...... a built-up edge occurrence hindering a robust evaluation of cutting fluid performance, if the data evaluation is based on surface finish only. Measurements of hole geometry provide documentation to recognize systematic error distorting the performance test....

  12. Reproducibility of a reaming test

    DEFF Research Database (Denmark)

    Pilny, Lukas; Müller, Pavel; De Chiffre, Leonardo

    2014-01-01

    The reproducibility of a reaming test was analysed to document its applicability as a performance test for cutting fluids. Reaming tests were carried out on a drilling machine using HSS reamers. Workpiece material was an austenitic stainless steel, machined using 4.75 m•min−1 cutting speed and 0......). Process reproducibility was assessed as the ability of different operators to ensure a consistent rating of individual lubricants. Absolute average values as well as experimental standard deviations of the evaluation parameters were calculated, and uncertainty budgeting was performed. Results document...... a built–up edge occurrence hindering a robust evaluation of cutting fluid performance, if the data evaluation is based on surface finish only. Measurements of hole geometry provide documentation to recognise systematic error distorting the performance test....

  13. Assessment of global and individual reproducibility of projective mapping with consumers

    OpenAIRE

    VIDAL, LETICIA; CADENA, RAFAEL SILVA; CORREA, SILVANA; ÁBALOS, ROSA A.; GÓMEZ, BEATRIZ; GIMÉNEZ, ANA; Varela, Paula; Ares, Gaston

    2014-01-01

    The popularity of projective mapping with consumers for sensory characterization has markedly increased in the last 5 years. To have confidence in this methodology,it is necessary to ensure that a similar product profile would emerge if the test was repeated. Also, deciding whether the study should be replicated or not is a key issue in test implementation. In this context, the aim of the present work was to evaluate global and individual reproducibility of projective mapping for sensory char...

  14. Towards reproducible experimental studies for non-convex polyhedral shaped particles

    Directory of Open Access Journals (Sweden)

    Wilke Daniel N.

    2017-01-01

    Full Text Available The packing density and flat bottomed hopper discharge of non-convex polyhedral particles are investigated in a systematic experimental study. The motivation for this study is two-fold. Firstly, to establish an approach to deliver quality experimental particle packing data for non-convex polyhedral particles that can be used for characterization and validation purposes of discrete element codes. Secondly, to make the reproducibility of experimental setups as convenient and readily available as possible using affordable and accessible technology. The primary technology for this study is fused deposition modeling used to 3D print polylactic acid (PLA particles using readily available 3D printer technology. A total of 8000 biodegradable particles were printed, 1000 white particles and 1000 black particles for each of the four particle types considered in this study. Reproducibility is one benefit of using fused deposition modeling to print particles, but an extremely important additional benefit is that specific particle properties can be explicitly controlled. As an example in this study the volume fraction of each particle can be controlled i.e. the effective particle density can be adjusted. In this study the particle volumes reduces drastically as the non-convexity is increased, however all printed white particles in this study have the same mass within 2% of each other.

  15. Towards reproducible experimental studies for non-convex polyhedral shaped particles

    Science.gov (United States)

    Wilke, Daniel N.; Pizette, Patrick; Govender, Nicolin; Abriak, Nor-Edine

    2017-06-01

    The packing density and flat bottomed hopper discharge of non-convex polyhedral particles are investigated in a systematic experimental study. The motivation for this study is two-fold. Firstly, to establish an approach to deliver quality experimental particle packing data for non-convex polyhedral particles that can be used for characterization and validation purposes of discrete element codes. Secondly, to make the reproducibility of experimental setups as convenient and readily available as possible using affordable and accessible technology. The primary technology for this study is fused deposition modeling used to 3D print polylactic acid (PLA) particles using readily available 3D printer technology. A total of 8000 biodegradable particles were printed, 1000 white particles and 1000 black particles for each of the four particle types considered in this study. Reproducibility is one benefit of using fused deposition modeling to print particles, but an extremely important additional benefit is that specific particle properties can be explicitly controlled. As an example in this study the volume fraction of each particle can be controlled i.e. the effective particle density can be adjusted. In this study the particle volumes reduces drastically as the non-convexity is increased, however all printed white particles in this study have the same mass within 2% of each other.

  16. Scientific Reproducibility in Biomedical Research: Provenance Metadata Ontology for Semantic Annotation of Study Description.

    Science.gov (United States)

    Sahoo, Satya S; Valdez, Joshua; Rueschman, Michael

    2016-01-01

    Scientific reproducibility is key to scientific progress as it allows the research community to build on validated results, protect patients from potentially harmful trial drugs derived from incorrect results, and reduce wastage of valuable resources. The National Institutes of Health (NIH) recently published a systematic guideline titled "Rigor and Reproducibility " for supporting reproducible research studies, which has also been accepted by several scientific journals. These journals will require published articles to conform to these new guidelines. Provenance metadata describes the history or origin of data and it has been long used in computer science to capture metadata information for ensuring data quality and supporting scientific reproducibility. In this paper, we describe the development of Provenance for Clinical and healthcare Research (ProvCaRe) framework together with a provenance ontology to support scientific reproducibility by formally modeling a core set of data elements representing details of research study. We extend the PROV Ontology (PROV-O), which has been recommended as the provenance representation model by World Wide Web Consortium (W3C), to represent both: (a) data provenance, and (b) process provenance. We use 124 study variables from 6 clinical research studies from the National Sleep Research Resource (NSRR) to evaluate the coverage of the provenance ontology. NSRR is the largest repository of NIH-funded sleep datasets with 50,000 studies from 36,000 participants. The provenance ontology reuses ontology concepts from existing biomedical ontologies, for example the Systematized Nomenclature of Medicine Clinical Terms (SNOMED CT), to model the provenance information of research studies. The ProvCaRe framework is being developed as part of the Big Data to Knowledge (BD2K) data provenance project.

  17. Reproducing Epidemiologic Research and Ensuring Transparency.

    Science.gov (United States)

    Coughlin, Steven S

    2017-08-15

    Measures for ensuring that epidemiologic studies are reproducible include making data sets and software available to other researchers so they can verify published findings, conduct alternative analyses of the data, and check for statistical errors or programming errors. Recent developments related to the reproducibility and transparency of epidemiologic studies include the creation of a global platform for sharing data from clinical trials and the anticipated future extension of the global platform to non-clinical trial data. Government agencies and departments such as the US Department of Veterans Affairs Cooperative Studies Program have also enhanced their data repositories and data sharing resources. The Institute of Medicine and the International Committee of Medical Journal Editors released guidance on sharing clinical trial data. The US National Institutes of Health has updated their data-sharing policies. In this issue of the Journal, Shepherd et al. (Am J Epidemiol. 2017;186:387-392) outline a pragmatic approach for reproducible research with sensitive data for studies for which data cannot be shared because of legal or ethical restrictions. Their proposed quasi-reproducible approach facilitates the dissemination of statistical methods and codes to independent researchers. Both reproducibility and quasi-reproducibility can increase transparency for critical evaluation, further dissemination of study methods, and expedite the exchange of ideas among researchers. © The Author(s) 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Reproducibility and validity of the Shanghai Men's Health Study physical activity questionnaire.

    Science.gov (United States)

    Jurj, Adriana L; Wen, Wanqing; Xiang, Yong-Bing; Matthews, Charles E; Liu, Dake; Zheng, Wei; Shu, Xiao-Ou

    2007-05-15

    Reproducibility and validity of the physical activity questionnaire (PAQ) used in the Shanghai Men's Health Study (2003-2006, People's Republic of China) was evaluated in a random sample of 196 participants aged 40-74 years. Participants completed a PAQ at baseline and again 1 year later, 12 monthly 7-day physical activity recalls, and four quarterly 1-week physical activity logs. Reproducibility was evaluated by using the two PAQs and validity by comparing the PAQs with 1-year averages of the two criterion measures: 7-day physical activity recall and physical activity log. The PAQ had moderate to high reproducibility for measuring adult exercise participation (kappa = 0.60) and energy expenditure (r(s) = 0.68), nonexercise activities (correlation coefficients = 0.42-0.68), and total daily energy expenditure (r(s) = 0.68, kappa(quartiles) = 0.47). Correlations between the PAQ and criterion measures of adult exercise were 0.45 (7-day physical activity recall) and 0.51 (physical activity log) for the first PAQ and 0.62 (7-day physical activity recall) and 0.71 (physical activity log) for the second PAQ. Correlations between PAQ nonexercise activities and the physical activity log and 7-day physical activity recall were 0.31-0.86. Correlations for total energy expenditure were high (0.62-0.77). Results indicate that the Shanghai Men's Health Study PAQ has reasonable reproducibility and validity for classifying men by their level of exercise and nonexercise activities in this cohort.

  19. Inter-scan reproducibility of coronary calcium measurement using Multi Detector-Row Computed Tomography (MDCT)

    International Nuclear Information System (INIS)

    Sabour, Siamak; Rutten, A.; Schouw, Y. T. van der; Atsma, F.; Grobbee, D. E.; Mali, W. P.; Bartelink, M. E. L.; Bots, M. L.; Prokop, M.

    2007-01-01

    Purpose. To assess inter-scan reproducibility of coronary calcium measurements obtained from Multi Detector-Row CT (MDCT) images and to evaluate whether this reproducibility is affected by different measurement protocols, slice thickness, cardiovascular risk factors and/or technical variables.Design. Cross-sectional study with repeated measurements. Materials and methods. The study population comprised 76 healthy women. Coronary calcium was assessed in these women twice in one session using 16-MDCT (Philips Mx 8000 IDT 16). Images were reconstructed with 1.5 mm slice thickness and 3.0 mm slice thickness. The 76 repeated scans were scored. The Agatston score, a volume measurement and a mass measurement were assessed. Reproducibility was determined by estimation of mean, absolute, relative difference, the weighted kappa value for agreement and the Intra-class correlation coefficient (ICCC).Results. Fifty-five participants (72.4%) had a coronary calcification of more than zero in Agatston (1.5 mm slice thickness). The reproducibility of coronary calcium measurements between scans in terms of ranking was excellent with Intra-class correlation coefficients of >0.98, and kappa values above 0.80. The absolute difference in calcium score between scans increased with increasing calcium levels, indicating that measurement error increases with increasing calcium levels. However, no relation was found between the mean difference in scores and calcium levels, indicating that the increase in measurement error is likely to result in random misclassification in calcium score. Reproducibility results were similar for 1.5 mm slices and for 3.0 mm slices, and equal for Agatston, volume and mass measurements.Conclusion. Inter-scan reproducibility of measurement of coronary calcium using images from MDCT is excellent, irrespective of slice thickness and type of calcium parameter

  20. Inter- and intra-rater reproducibility of semiautomatic determination of volume parameters in cardiac magnetic resonance imaging

    International Nuclear Information System (INIS)

    Trieb, Thomas; Glodny, Bernhard; Scheiblhofer, Martin; Wolf, Christian; Metzler, Bernhard; Pachinger, Otmar; Jaschke, Werner R.; Schocke, Michael F.H.

    2008-01-01

    Purpose: The purpose of this study was to evaluate inter- and intra-rater reproducibility in volume assessment using cardiac magnetic resonance imaging (CMRI). Methods: Twenty-five healthy volunteers and 106 patients were included into this retrospective study and received CMRI. The patients were divided in three groups (group I, 80 patients with arrhythmia; group II, 20 patients with cardiomyopathy; group III, 6 patients after correction of septum defects). Therefore, the images were semiautomatically segmented by an experienced and an unexperienced radiologists. The analysis of end-diastolic volume (EDV), end-systolic volume (ESV) and stroke volume (SV) as well as ejection fraction (EF) and myocardial mass (MM) were performed twice by an experienced and an unexperienced radiologists. The intra-class correlation coefficients (ICC) were determined for the evaluation of inter- and intra-rater variance. Results: The intra-rater reproducibility for determination of EF, ESV, EDV and MM was excellent with ICCs ranging from 0.88 to 0.99 (all p < 0.001). The inter-observer reproducibility for these parameters was also excellent with ICCs ranging from 0.91 to 0.98 (all p < 0.001). The assessment of the SV showed an excellent intra-rater agreement with ICCs of 0.96 and 0.92 (both p < 0.001), but only a moderate ICC for the inter-rater reproducibility (0.54, p < 0.001). Conclusions: Our study shows that assessment of cardiac volumes can be performed on CMRIs with an excellent reproducibility by both experienced and unexperienced investigators

  1. MRI assessment of knee osteoarthritis: Knee Osteoarthritis Scoring System (KOSS) - inter-observer and intra-observer reproducibility of a compartment-based scoring system

    International Nuclear Information System (INIS)

    Kornaat, Peter R.; Ceulemans, Ruth Y.T.; Kroon, Herman M.; Bloem, Johan L.; Riyazi, Naghmeh; Kloppenburg, Margreet; Carter, Wayne O.; Woodworth, Thasia G.

    2005-01-01

    To develop a scoring system for quantifying osteoarthritic changes of the knee as identified by magnetic resonance (MR) imaging, and to determine its inter- and intra-observer reproducibility, in order to monitor medical therapy in research studies. Two independent observers evaluated 25 consecutive MR examinations of the knee in patients with previously defined clinical symptoms and radiological signs of osteoarthritis. We acquired on a 1.5 T system: coronal and sagittal proton density- and T2-weighted dual spin echo (SE) images, sagittal three-dimensional T1-weighted gradient echo (GE) images with fat suppression, and axial dual turbo SE images with fat suppression. Images were scored for the presence of cartilaginous lesions, osteophytes, subchondral cysts, bone marrow edema, and for meniscal abnormalities. Presence and size of effusion, synovitis and Baker's cyst were recorded. All parameters were ranked on a previously defined, semiquantitative scale, reflecting increasing severity of findings. Kappa, weighted kappa and intraclass correlation coefficient (ICC) were used to determine inter- and intra-observer variability. Inter-observer reproducibility was good (ICC value 0.77). Inter- and intra-observer reproducibility for individual parameters was good to very good (inter-observer ICC value 0.63-0.91; intra-observer ICC value 0.76-0.96). The presented comprehensive MR scoring system for osteoarthritic changes of the knee has a good to very good inter-observer and intra-observer reproducibility. Thus the score form with its definitions can be used for standardized assessment of osteoarthritic changes to monitor medical therapy in research studies. (orig.)

  2. Reproducibility of small animal cine and scar cardiac magnetic resonance imaging using a clinical 3.0 tesla system

    International Nuclear Information System (INIS)

    Manka, Robert; Jahnke, Cosima; Hucko, Thomas; Dietrich, Thore; Gebker, Rolf; Schnackenburg, Bernhard; Graf, Kristof; Paetsch, Ingo

    2013-01-01

    To evaluate the inter-study, inter-reader and intra-reader reproducibility of cardiac cine and scar imaging in rats using a clinical 3.0 Tesla magnetic resonance (MR) system. Thirty-three adult rats (Sprague–Dawley) were imaged 24 hours after surgical occlusion of the left anterior descending coronary artery using a 3.0 Tesla clinical MR scanner (Philips Healthcare, Best, The Netherlands) equipped with a dedicated 70 mm solenoid receive-only coil. Left-ventricular (LV) volumes, mass, ejection fraction and amount of myocardial scar tissue were measured. Intra-and inter-observer reproducibility was assessed in all animals. In addition, repeat MR exams were performed in 6 randomly chosen rats within 24 hours to assess inter-study reproducibility. The MR imaging protocol was successfully completed in 32 (97%) animals. Bland-Altman analysis demonstrated high intra-reader reproducibility (mean bias%: LV end-diastolic volume (LVEDV), -1.7%; LV end-systolic volume (LVESV), -2.2%; LV ejection fraction (LVEF), 1.0%; LV mass, -2.7%; and scar mass, -1.2%) and high inter-reader reproducibility (mean bias%: LVEDV, 3.3%; LVESV, 6.2%; LVEF, -4.8%; LV mass, -1.9%; and scar mass, -1.8%). In addition, a high inter-study reproducibility was found (mean bias%: LVEDV, 0.1%; LVESV, -1.8%; LVEF, 1.0%; LV mass, -4.6%; and scar mass, -6.2%). Cardiac MR imaging of rats yielded highly reproducible measurements of cardiac volumes/function and myocardial infarct size on a clinical 3.0 Tesla MR scanner system. Consequently, more widely available high field clinical MR scanners can be employed for small animal imaging of the heart e.g. when aiming at serial assessments during therapeutic intervention studies

  3. Reliability versus reproducibility

    International Nuclear Information System (INIS)

    Lautzenheiser, C.E.

    1976-01-01

    Defect detection and reproducibility of results are two separate but closely related subjects. It is axiomatic that a defect must be detected from examination to examination or reproducibility of results is very poor. On the other hand, a defect can be detected on each of subsequent examinations for higher reliability and still have poor reproducibility of results

  4. Reproducibility of airway luminal size in asthma measured by HRCT.

    Science.gov (United States)

    Brown, Robert H; Henderson, Robert J; Sugar, Elizabeth A; Holbrook, Janet T; Wise, Robert A

    2017-10-01

    Brown RH, Henderson RJ, Sugar EA, Holbrook JT, Wise RA, on behalf of the American Lung Association Airways Clinical Research Centers. Reproducibility of airway luminal size in asthma measured by HRCT. J Appl Physiol 123: 876-883, 2017. First published July 13, 2017; doi:10.1152/japplphysiol.00307.2017.-High-resolution CT (HRCT) is a well-established imaging technology used to measure lung and airway morphology in vivo. However, there is a surprising lack of studies examining HRCT reproducibility. The CPAP Trial was a multicenter, randomized, three-parallel-arm, sham-controlled 12-wk clinical trial to assess the use of a nocturnal continuous positive airway pressure (CPAP) device on airway reactivity to methacholine. The lack of a treatment effect of CPAP on clinical or HRCT measures provided an opportunity for the current analysis. We assessed the reproducibility of HRCT imaging over 12 wk. Intraclass correlation coefficients (ICCs) were calculated for individual airway segments, individual lung lobes, both lungs, and air trapping. The ICC [95% confidence interval (CI)] for airway luminal size at total lung capacity ranged from 0.95 (0.91, 0.97) to 0.47 (0.27, 0.69). The ICC (95% CI) for airway luminal size at functional residual capacity ranged from 0.91 (0.85, 0.95) to 0.32 (0.11, 0.65). The ICC measurements for airway distensibility index and wall thickness were lower, ranging from poor (0.08) to moderate (0.63) agreement. The ICC for air trapping at functional residual capacity was 0.89 (0.81, 0.94) and varied only modestly by lobe from 0.76 (0.61, 0.87) to 0.95 (0.92, 0.97). In stable well-controlled asthmatic subjects, it is possible to reproducibly image unstimulated airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. NEW & NOTEWORTHY There is a surprising lack

  5. Navicular bone position determined by positional MRI: a reproducibility study

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Philip; Nybing, Janus D. [Copenhagen University Hospital Frederiksberg and Bispebjerg, Department of Radiology, Frederiksberg (Denmark); Johannsen, Finn E.; Stallknecht, Sandra E. [Copenhagen University Hospital Bispebjerg, Institute of Sports Medicine Copenhagen, Copenhagen, NV (Denmark); Hangaard, Stine; Hansen, Bjarke B. [Copenhagen University Hospital Frederiksberg, Parker Institute, Department of Rheumatology, Frederiksberg (Denmark); Boesen, Mikael [Copenhagen University Hospital Frederiksberg and Bispebjerg, Department of Radiology, Frederiksberg (Denmark); Copenhagen University Hospital Frederiksberg, Parker Institute, Department of Rheumatology, Frederiksberg (Denmark)

    2016-02-15

    To examine intraobserver, interobserver and between-day reproducibility of positional MRI for evaluation of navicular bone height (NVH) and medial navicular position (MNP). Positional MRI (pMRI) of the foot was performed on ten healthy participants (0.25 T G-scanner). Scanning was performed in supine and standing position, respectively. Two radiologists evaluated the images in a blinded manner. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC) and 95 % limits of agreement as a percentage of the mean (LOA%). Intraobserver and interobserver reliability was ''substantial'' in both supine and standing position (ICC 0.86-0.98) and showed good agreement (LOA% 4.9-14.7 %). Between-day reliability of navicular height and medial navicular position in standing position remained substantial (ICC 0.85-0.92) with adequate agreement (LOA% 8.3-19.8 %). In supine position between-day reliability was ''moderate'' for NVH (ICC 0.72) and ''slight'' for MNP (ICC 0.39). Agreement remained adequate between-days for MNP in supine position (LOA% 17.7 %), but it was less than adequate for NVH in supine position (LOA% 24.2 %). Navicular height and medial navicular position can be measured by pMRI in a very reproducible manner within and between observers. Increased measurement variation is observed between-days in supine position, which may be due to small positional differences or other unknown biomechanical factors. (orig.)

  6. Navicular bone position determined by positional MRI: a reproducibility study

    International Nuclear Information System (INIS)

    Hansen, Philip; Nybing, Janus D.; Johannsen, Finn E.; Stallknecht, Sandra E.; Hangaard, Stine; Hansen, Bjarke B.; Boesen, Mikael

    2016-01-01

    To examine intraobserver, interobserver and between-day reproducibility of positional MRI for evaluation of navicular bone height (NVH) and medial navicular position (MNP). Positional MRI (pMRI) of the foot was performed on ten healthy participants (0.25 T G-scanner). Scanning was performed in supine and standing position, respectively. Two radiologists evaluated the images in a blinded manner. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC) and 95 % limits of agreement as a percentage of the mean (LOA%). Intraobserver and interobserver reliability was ''substantial'' in both supine and standing position (ICC 0.86-0.98) and showed good agreement (LOA% 4.9-14.7 %). Between-day reliability of navicular height and medial navicular position in standing position remained substantial (ICC 0.85-0.92) with adequate agreement (LOA% 8.3-19.8 %). In supine position between-day reliability was ''moderate'' for NVH (ICC 0.72) and ''slight'' for MNP (ICC 0.39). Agreement remained adequate between-days for MNP in supine position (LOA% 17.7 %), but it was less than adequate for NVH in supine position (LOA% 24.2 %). Navicular height and medial navicular position can be measured by pMRI in a very reproducible manner within and between observers. Increased measurement variation is observed between-days in supine position, which may be due to small positional differences or other unknown biomechanical factors. (orig.)

  7. Brazilian Portuguese translation, cross-cultural adaptation and reproducibility assessment of the modified Bristol Stool Form Scale for children.

    Science.gov (United States)

    Jozala, Debora Rodrigues; Oliveira, Isabelle Stefan de Faria; Ortolan, Erika Veruska Paiva; Oliveira Junior, Wilson Elias de; Comes, Giovana Tuccille; Cassettari, Vanessa Mello Granado; Self, Mariella Marie; Lourenção, Pedro Luiz Toledo de Arruda

    2018-03-15

    To translate and culturally adapt the modified Bristol Stool Form Scale for children into Brazilian Portuguese, and to evaluate the reproducibility of the translated version. The stage of translation and cross-cultural adaptation was performed according to an internationally accepted methodology, including the translation, back-translation, and pretest application of the translated version to a sample of 74 children to evaluate the degree of understanding. The reproducibility of the translated scale was assessed by applying the final version of Brazilian Portuguese modified Bristol Stool Form Scale for children to a sample of 64 children and 25 healthcare professionals, who were asked to correlate a randomly selected description from the translated scale with the corresponding representative illustration of the stool type. The final version of Brazilian Portuguese modified Bristol Stool Form Scale for children were evidently reproducible, since almost complete agreement (k>0,8) was obtained among the translated descriptions and illustrations of the stool types, both among the children and the group of specialists. The Brazilian Portuguese modified Bristol Stool Form Scale for children was shown to be reliable in providing very similar results for the same respondents at different times and for different examiners. The Brazilian Portuguese modified Bristol Stool Form Scale for children is reproducible; it can be applied in clinical practice and in scientific research in Brazil. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  8. Reproducibility principles, problems, practices, and prospects

    CERN Document Server

    Maasen, Sabine

    2016-01-01

    Featuring peer-reviewed contributions from noted experts in their fields of research, Reproducibility: Principles, Problems, Practices, and Prospects presents state-of-the-art approaches to reproducibility, the gold standard sound science, from multi- and interdisciplinary perspectives. Including comprehensive coverage for implementing and reflecting the norm of reproducibility in various pertinent fields of research, the book focuses on how the reproducibility of results is applied, how it may be limited, and how such limitations can be understood or even controlled in the natural sciences, computational sciences, life sciences, social sciences, and studies of science and technology. The book presents many chapters devoted to a variety of methods and techniques, as well as their epistemic and ontological underpinnings, which have been developed to safeguard reproducible research and curtail deficits and failures. The book also investigates the political, historical, and social practices that underlie repro...

  9. Reproducibility study of TLD-100 micro-cubes at radiotherapy dose level

    International Nuclear Information System (INIS)

    Rosa, Luiz Antonio R. da; Regulla, Dieter F.; Fill, Ute A.

    1999-01-01

    The precision of the thermoluminescent response of Harshaw micro-cube dosimeters (TLD-100), evaluated in both Harshaw thermoluminescent readers 5500 and 3500, for 1 Gy dose value, was investigated. The mean reproducibility for micro-cubes, pre-readout annealed at 100 deg. C for 15 min, evaluated with the manual planchet reader 3500, is 0.61% (1 standard deviation). When micro-cubes are evaluated with the automated hot-gas reader 5500, reproducibility values are undoubtedly worse, mean reproducibility for numerically stabilised dosimeters being equal to 3.27% (1 standard deviation). These results indicate that the reader model 5500, or, at least, the instrument used for the present measurements, is not adequate for micro-cube evaluation, if precise and accurate dosimetry is required. The difference in precision is apparently due to geometry inconsistencies in the orientation of the imperfect micro-cube faces during readout, requiring careful and manual reproducible arrangement of the selected micro-cube faces in contact with the manual reader planchet

  10. Reproducibility of peak filling and peak emptying rate determined by cardiovascular magnetic resonance imaging for assessment of biventricular systolic and diastolic dysfunction in patients with pulmonary arterial hypertension

    DEFF Research Database (Denmark)

    Göransson, Christoffer; Vejlstrup, Niels; Carlsen, Jørn

    2018-01-01

    Right ventricular (RV) and left ventricular (LV) diastolic stiffness may be independent contributors to disease progression in pulmonary arterial hypertension (PAH). The aims of this study are to assess reproducibility of peak emptying rate (PER) and early diastolic peak filling rate (PFR) for both...

  11. Feasibility, Reproducibility, and Agreement between Different Speckle Tracking Echocardiographic Techniques for the Assessment of Longitudinal Deformation

    Directory of Open Access Journals (Sweden)

    Sergio Buccheri

    2013-01-01

    Full Text Available Background. Left ventricular (LV longitudinal deformation can be assessed with new echocardiographic techniques like triplane echocardiography (3PE and four-dimensional echocardiography (4DE. We aimed to assess the feasibility, reproducibility, and agreement between these different speckle-tracking techniques for the assessment of longitudinal deformation. Methods. 101 consecutive subjects underwent echocardiographic examination. 2D cine loops from the apical views, a triplane view, and an LV 4D full volume were acquired in all subjects. LV longitudinal strain was obtained for each imaging modality. Results. 2DE analysis of LV strain was feasible in 90/101 subjects, 3PE strain in 89/101, and 4DE strain in 90/101. The mean value of 2DE and 3PE longitudinal strains was significantly higher with respect to 4DE. The relationship between 2DE and 3PE derived strains (r=0.782 was significantly higher (z=3.72, P<0.001 than that between 2DE and 4DE (r=0.429 and that between 3PE and 4DE (r=0.510; z=3.09, P=0.001. The mean bias between 2DE and 4DE strains was -6.61±7.31% while -6.42±6.81% between 3PE and 4DE strains; the bias between 2DE and 3PE strain was of 0.21±4.16%. Intraobserver and interobserver variabilities were acceptable among the techniques. Conclusions. Echocardiographic techniques for the assessment of longitudinal deformation are not interchangeable, and further studies are needed to assess specific reference values.

  12. The Need for Reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Robey, Robert W. [Los Alamos National Laboratory

    2016-06-27

    The purpose of this presentation is to consider issues of reproducibility, specifically it determines whether bitwise reproducible computation is possible, if computational research in DOE improves its publication process, and if reproducible results can be achieved apart from the peer review process?

  13. An MRI-based technique for assessment of lower extremity deformities - reproducibility, accuracy, and clinical application

    International Nuclear Information System (INIS)

    Hinterwimmer, Stefan; Graichen, Heiko; Vogl, Thomas J.; Abolmaali, Nasreddin

    2008-01-01

    The hypothesis of this study was that length, torsion, and axis of a leg phantom can be measured accurately and reproducibly by magnetic resonance imaging (MRI) and that this can be applied to patients with leg deformities. Two phantoms and 30 patients (genu varum, n=15; genu valgum, n=15) were investigated using an optimized MRI technique. Reference measurements were performed with a micrometer screw and a goniometer. Patient leg length and axis were compared with long radiographs in bipedal stance. Intra- and interobserver reproducibility and accuracy were calculated using the mean absolute difference (MAD) and the 95% confidence interval. In patients, comparisons were done using a paired Student's t-test. MAD, intraobserver MAD, and interobserver MAD were 0.03, 0.03, 0.04 mm (length); 0.98, 1.2, 0.98 (torsion); and 0.18, 0.23, 0.22 (axis), respectively. In patients, leg length was underestimated by MRI (-2.4 ± 0.7%; 1.9±0.7 cm; P 0.05), while it was significantly underestimated in valgus knees (-3.6 ± 2.8 ; P<0.05). The phantom study revealed that leg length, torsion, and axis can be measured accurately and reproducibly by MRI. Although underestimation of leg length and HKA in valgus knees occurred, this optimized MRI technique can be applied to patients with leg deformities. (orig.)

  14. Reproducibility of biomarkers in induced sputum and in serum from chronic smokers.

    Science.gov (United States)

    Zuiker, Rob G J A; Kamerling, Ingrid M C; Morelli, Nicoletta; Calderon, Cesar; Boot, J Diderik; de Kam, Marieke; Diamant, Zuzana; Burggraaf, Jacobus; Cohen, Adam F

    2015-08-01

    Soluble inflammatory markers obtained from non-invasive airway sampling such as induced sputum may be useful biomarkers for targeted pharmaceutical interventions. However, before these soluble markers can be used as potential targets, their variability and reproducibility need to be established in distinct study populations. This study aimed to assess the reproducibility of biomarkers obtained from induced sputum and serum in chronic smokers and non-smokers. Sputum and serum samples were obtained from 16 healthy non-smokers and 16 asymptomatic chronic smokers (for both groups: 8M/8F, 30-52 years, FEV1 ≥80% pred.; ≥10 pack years for the smokers) on 2 separate visits 4-10 days apart. Soluble markers in serum and sputum were analysed by ELISA. The differences between smokers vs non-smokers were analysed with a t-test and variability was assessed on log-transformed data by a mixed model ANOVA. Analysable sputum samples could be obtained from all 32 subjects. In both study populations neutrophils and macrophages were the predominant cell types. Serum Pulmonary Surfactant Associated Protein D had favourable reproducibility criteria for reliability ratio (0.99), intra-subject coefficient of variation (11.2%) and the Bland Altman limits of agreement. Furthermore, chronic smokers, compared to non-smokers, had significantly higher sputum concentrations of IL-8 (1094.6 pg/mL vs 460.8 pg/mL, p = 0.006)), and higher serum concentrations of Pulmonary Surfactant Associated Protein D (110.9 pg/mL vs 64.7 pg/mL, p = 0.019), and lower concentrations of Serum Amyloid A (1352.4 pg/mL vs 2297.5 pg/mL, p = 0.022). Serum Pulmonary Surfactant Associated Protein D proved to be a biomarker that fulfilled the criteria for reproducibility in both study groups. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Reproducibility of GBPI - gated blood-pool imaging in LVEF - left ventricle ejection fraction assessment in patients with big infarcts and a control group

    International Nuclear Information System (INIS)

    Guevara, David Ladron de; Lobo, Gabriel; Perez, Andres; Jimenez, Cesar; Wolff, Carlos

    2003-01-01

    GBPI allows to study global and regional myocardial contractility, calculating LVEF accurately and easily. Intra and inter observer reproducibility of these measurements depends of clinical group studied, acquisition parameters, gamma camera and software used, and operator. The aim of this study was to evaluate the LVEF assessment reproducibility in patients with big infarcts and a control group, using two different gamma cameras. Material and method. GBPI of 13 patients with large infarcts and 12 healthy young control individuals were done, using sequentially both gamma camera Picker 37/15 and SMV DST Xli, with exactly the same acquisition parameters in both. Each individual was injected once with 925 MBq (25 mCi) of in vitro labelled Tc 99 m red blood cells. Ten LVEF measurements by patient were done, calculating the variability coefficient (VC) of these values for each clinical group in both gamma cameras for comparison. Correlation and Bland-Altman analysis of LVEF values were performed. Results. Infarcted patients had higher values of VC than controls (3.5% vs 2.3% in Picker, 3.5% vs 2.1% in SMV DST XLi). Variability of LVEF measurements of both gamma cameras was almost identical. Picker equipment yielded LVEF values slightly higher than SMV DST XLi equipment, especially in infarcted patients. However, a strong correlation between both gamma cameras was found (r:0.97).Conclusion. Reproducibility of both gamma cameras is almost identical, very high, and significantly higher in control individuals than infarcted patients. (author)

  16. Reproducibility of current perception threshold with the Neurometer(®) vs the Stimpod NMS450 peripheral nerve stimulator in healthy volunteers: an observational study.

    Science.gov (United States)

    Tsui, Ban C H; Shakespeare, Timothy J; Leung, Danika H; Tsui, Jeremy H; Corry, Gareth N

    2013-08-01

    Current methods of assessing nerve blocks, such as loss of perception to cold sensation, are subjective at best. Transcutaneous nerve stimulation is an alternative method that has previously been used to measure the current perception threshold (CPT) in individuals with neuropathic conditions, and various devices to measure CPT are commercially available. Nevertheless, the device must provide reproducible results to be used as an objective tool for assessing nerve blocks. We recruited ten healthy volunteers to examine CPT reproducibility using the Neurometer(®) and the Stimpod NMS450 peripheral nerve stimulator. Each subject's CPT was determined for the median (second digit) and ulnar (fifth digit) nerve sensory distributions on both hands - with the Neurometer at 5 Hz, 250 Hz, and 2000 Hz and with the Stimpod at pulse widths of 0.1 msec, 0.3 msec, 0.5 msec, and 1.0 msec, both at 5 Hz and 2 Hz. Intraclass correlation coefficients (ICC) were also calculated to assess reproducibility; acceptable ICCs were defined as ≥ 0.4. The ICC values for the Stimpod ranged from 0.425-0.79, depending on pulse width, digit, and stimulation; ICCs for the Neurometer were 0.615 and 0.735 at 250 and 2,000 Hz, respectively. These values were considered acceptable; however, the Neurometer performed less efficiently at 5 Hz (ICCs for the second and fifth digits were 0.292 and 0.318, respectively). Overall, the Stimpod device displayed good to excellent reproducibility in measuring CPT in healthy volunteers. The Neurometer displayed poor reproducibility at low frequency (5 Hz). These results suggest that peripheral nerve stimulators may be potential devices for measuring CPT to assess nerve blocks.

  17. Reproducibility of Left Ventricular Mass by Echocardiogram in the ELSA-Brasil

    Directory of Open Access Journals (Sweden)

    Alexandre Pereira Tognon

    2015-02-01

    Full Text Available Background: Echocardiography, though non-invasive and having relatively low-cost, presents issues of variability which can limit its use in epidemiological studies. Objective: To evaluate left ventricular mass reproducibility when assessed at acquisition (online compared to when assessed at a reading center after electronic transmission (offline and also when assessed by different readers at the reading center. Methods: Echocardiographers from the 6 ELSA-Brasil study investigation centers measured the left ventricular mass online during the acquisition from 124 studies before transmitting to the reading center, where studies were read according to the study protocol. Half of these studies were blindly read by a second reader in the reading center. Results: From the 124 echocardiograms, 5 (4% were considered not measurable. Among the remaining 119, 72 (61% were women, mean age was 50.2 ± 7.0 years and 2 had structural myocardial abnormalities. Images were considered to be optimal/ good by the reading center for 110 (92.4% cases. No significant difference existed between online and offline measurements (1,29 g, CI 95% −3.60-6.19, and the intraclass correlation coefficient between them was 0.79 (CI 95% 0.71-0.85. For images read by two readers, the intraclass correlation coefficient was 0.86 (CI 95% 0.78-0.91. Conclusion: There were no significant drifts between online and offline left ventricular mass measurements, and reproducibility was similar to that described in previous studies. Central quantitative assessment of echocardiographic studies in reading centers, as performed in the ELSA-Brasil study, is feasible and useful in clinical and epidemiological studies performed in our setting.

  18. Validity and reproducibility of a food frequency questionnaire for adults of São Paulo, Brazil.

    Science.gov (United States)

    Selem, Soraya Sant'Ana de Castro; Carvalho, Aline Martins de; Verly-Junior, Eliseu; Carlos, Jackeline Venâncio; Teixeira, Juliana Araujo; Marchioni, Dirce Maria Lobo; Fisberg, Regina Mara

    2014-12-01

    To assess the validity and reproducibility of a food frequency questionnaire developed for estimating the food consumption of adults in São Paulo, Brazil, based population study. A sample of individuals aged above 20 years, of both genders, living in São Paulo, was used for the validation study (n = 77) and reproducibility study (n = 74) of the food frequency questionnaire. To verify the validity and reproducibility of energy and 19 nutrients were applied two food frequency questionnaires (60 items) and three 24-hour dietary recalls (24HR - reference method). The validity was verified by Spearman correlation coefficient (crude and de-attenuated) and weighted Kappa, and reproducibility by intraclass correlation coefficients and weighted kappa. In analyzes of validity de-attenuated correlation coefficients ranged from 0.21 (carbohydrate) to 0.74 (energy), and weighted kappa exceeded 0.40 for 30% of the nutrients. Polyunsaturated fat and folate did not show significant correlation and weighted kappa. In reproducibility correlation coefficients ranged from 0.36 (polyunsaturated fat) to 0.69 (calcium), and weighted kappa exceeded 0.40 for 80% of the nutrients. The food frequency questionnaire analyzed has good validity and reproducibility for estimating the food consumption of adults in São Paulo compared to the reference method, so it is an appropriate instrument to be used in epidemiological studies on similar populations. Estimates of polyunsaturated fat and folate should be interpreted with caution.

  19. [Good reproducibility of a 14-item food frequency questionnaire for cardiovascular prevention in students].

    Science.gov (United States)

    Balquet, L; Noury-Desvaux, B; Jaquinandi, V; Mahé, G

    2015-02-01

    Diet is a modifiable risk factor of atherosclerosis. A 14-item food frequency questionnaire (FFQ) has been developed. The reproducibility of this FFQ is unknown in a student population whereas its use could be of interest. This FFQ allows calculating different scores for different food groups involved in cardiovascular disease. The vascular dietary score (VDS) can be calculated. The VSD ranges from -17 to +19. The higher the VSD, the better diet. Reproducibility was assessed in sports faculty students using mean tests comparing measurement 1 and 2 (minimum time interval ≥ 7 days) and intra-class correlation (ICC) tests. Thirty students (50% men) were included in a French Sports Faculty. Time between two FFQ assessments was 19 ± 9 days. Mean VSD was 0.50 ± 3.70 for the first assessment and 0.30 ± 3.14 for the second one (non significant). Any score for each food group was statistically significant between the first and the second measurement. ICC of VSD was 0.68 [95% confidence interval: 0.43-0.83]. This FFQ that assesses a risky vascular diet has good reproducibility. This tool could be useful for large studies involving students. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  20. Reproducibility and Validity of a Food Frequency Questionnaire for Assessing Dietary Consumption via the Dietary Pattern Method in a Chinese Rural Population.

    Science.gov (United States)

    Liu, Xudong; Wang, Xiaorong; Lin, Sihao; Song, Qingkun; Lao, Xiangqian; Yu, Ignatius Tak-Sun

    2015-01-01

    This study was conducted to assess the reproducibility and validity of a food frequency questionnaire (FFQ) that was developed to assess the overall dietary consumption via dietary pattern method in a rural population in southwest China. A total of 179 participants aged between 40 and 70 years old were included in this study. Participants administered FFQ at baseline (FFQ1) and one year later (FFQ2) to assess the reproducibility. Six 3-day 24-hour recalls (24HRs) were completed between the administrations of two FFQs to determine the validity. Dietary patterns from three separate dietary sources were derived by using principle component factor analysis. Comparisons between dietary pattern scores were made by using Pearson or intraclass correlation coefficient, cross-classification analysis, weighted kappa (κ) statistic and Bland-Altman analysis. The de-attenuated method was adopted to correct the monthly and seasonally variation and the partial correlation analysis was used correct the influence by total energy intake. Two major dietary factors, labeled as prudent pattern and processed food pattern, were identified. The prudent pattern was characterized by higher factor loadings of wheat, rice, fresh vegetables, bean products, nuts, red meat, white meat and fresh eggs; and the processed food pattern was characterized by higher factor loadings of pickled vegetables, preserved vegetables and salted meat. Between Two FFQs, intraclass correlation coefficients were 0.57 for prudent pattern and 0.55 for processed food pattern, partial Pearson correlation coefficients were 0.51 for the prudent pattern and 0.56 for the processed food pattern; weighted κ statistic ranged from 0.45 (for the prudent pattern) to 0.56 (for the processed food pattern). Between FFQs and 24HRs, de-attenuated correlation coefficients ranged from 0.54 to 0.78 for the prudent pattern and from 0.55 to 0.61 for the processed food pattern; partial Pearson correlation coefficients ranged from 0.41 to 0

  1. Reproducibility and Validity of a Food Frequency Questionnaire for Assessing Dietary Consumption via the Dietary Pattern Method in a Chinese Rural Population.

    Directory of Open Access Journals (Sweden)

    Xudong Liu

    Full Text Available This study was conducted to assess the reproducibility and validity of a food frequency questionnaire (FFQ that was developed to assess the overall dietary consumption via dietary pattern method in a rural population in southwest China.A total of 179 participants aged between 40 and 70 years old were included in this study. Participants administered FFQ at baseline (FFQ1 and one year later (FFQ2 to assess the reproducibility. Six 3-day 24-hour recalls (24HRs were completed between the administrations of two FFQs to determine the validity. Dietary patterns from three separate dietary sources were derived by using principle component factor analysis. Comparisons between dietary pattern scores were made by using Pearson or intraclass correlation coefficient, cross-classification analysis, weighted kappa (κ statistic and Bland-Altman analysis. The de-attenuated method was adopted to correct the monthly and seasonally variation and the partial correlation analysis was used correct the influence by total energy intake.Two major dietary factors, labeled as prudent pattern and processed food pattern, were identified. The prudent pattern was characterized by higher factor loadings of wheat, rice, fresh vegetables, bean products, nuts, red meat, white meat and fresh eggs; and the processed food pattern was characterized by higher factor loadings of pickled vegetables, preserved vegetables and salted meat. Between Two FFQs, intraclass correlation coefficients were 0.57 for prudent pattern and 0.55 for processed food pattern, partial Pearson correlation coefficients were 0.51 for the prudent pattern and 0.56 for the processed food pattern; weighted κ statistic ranged from 0.45 (for the prudent pattern to 0.56 (for the processed food pattern. Between FFQs and 24HRs, de-attenuated correlation coefficients ranged from 0.54 to 0.78 for the prudent pattern and from 0.55 to 0.61 for the processed food pattern; partial Pearson correlation coefficients ranged

  2. Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study.

    Science.gov (United States)

    Jeong, Ii-Do; Kim, Woong-Chul; Park, Jinyoung; Kim, Chong-Myeong; Kim, Ji-Hwan

    2017-08-01

    This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (α=.05). The RMS value of lithium disilicate crown was 29.2 (4.1) µm and 17.6 (5.5) µm on the outer and inner surfaces, respectively, whereas these values were 18.6 (2.0) µm and 20.6 (5.1) µm for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface ( P <.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

  3. Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented

    DEFF Research Database (Denmark)

    Huisman, Jennifer; Egede, Rasmus; Rdzanek, Adam

    2012-01-01

    To assess in a multicenter design the between-center reproducibility of volumetric virtual histology intravascular ultrasound (VH-IVUS) measurements with a semi-automated, computer-assisted contour detection system in coronary lesions that were consecutively stented. To evaluate the reproducibility...... of volumetric VH-IVUS measurements, experienced analysts of 4 European IVUS centers performed independent analyses (in total 8,052 cross-sectional analyses) to obtain volumetric data of 40 coronary segments (length 20.0 ± 0.3 mm) from target lesions prior to percutaneous intervention that were performed...... in the setting of stable (65%) or unstable angina pectoris (35%). Geometric and compositional VH-IVUS measurements were highly correlated for the different comparisons. Overall intraclass correlation for vessel, lumen, plaque volume and plaque burden was 0.99, 0.92, 0.96, and 0.83, respectively; for fibrous...

  4. Reproducibility and Reliability of the Quality of Life Questionnaire in Patients With Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Rita Simone Lopes Moreira

    2016-03-01

    Full Text Available Abstract Background: Studies have shown the impact of atrial fibrillation (AF on the patients' quality of life. Specific questionnaires enable the evaluation of relevant events. We previously developed a questionnaire to assess the quality of life of patients with AF (AFQLQ version 1, which was reviewed in this study, and new domains were added. Objective: To demonstrate the reproducibility of the AFQLQ version 2 (AFQLQ v.2, which included the domains of fatigue, illness perception and well-being. Methods: We applied 160 questionnaires (AFQLQ v.2 and SF-36 to 40 patients, at baseline and 15 days after, to measure inter- and intraobserver reproducibility. The analysis of quality of life stability was determined by test-retest, applying the Bartko intraclass correlation coefficient (ICC. Internal consistency was assessed by Cronbach's alpha test. Results: The total score of the test-retest (n = 40 had an ICC of 0.98 in the AFQLQ v.2, and of 0.94 in the SF36. In assessing the intra- and interobserver reproducibility of the AFQLQ v.2, the ICC reliability was 0.98 and 0.97, respectively. The internal consistency had a Cronbach's alpha coefficient of 0.82, compatible with good agreement of the AFQLQ v.2. Conclusion: The AFQLQ v.2 performed better than its previous version. Similarly, the domains added contributed to make it more comprehensive and robust to assess the quality of life of patients with AF.

  5. Reproducibility and Reliability of Repeated Quantitative Fluorescence Angiography

    DEFF Research Database (Denmark)

    Nerup, Nikolaj; Knudsen, Kristine Bach Korsholm; Ambrus, Rikard

    2017-01-01

    INTRODUCTION: When using fluorescence angiography (FA) in perioperative perfusion assessment, repeated measures with re-injections of fluorescent dye (ICG) may be required. However, repeated injections may cause saturation of dye in the tissue, exceeding the limit of fluorescence intensity...... that the camera can detect. As the emission of fluorescence is dependent of the excitatory light intensity, reduction of this may solve the problem. The aim of the present study was to investigate the reproducibility and reliability of repeated quantitative FA during a reduction of excitatory light....

  6. Reproducibility of 3D kinematics and surface electromyography measurements of mastication.

    Science.gov (United States)

    Remijn, Lianne; Groen, Brenda E; Speyer, Renée; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2016-03-01

    The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland-Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for 'time-to-swallow', 'time-to-transport' and 'number of chewing cycles', but ranged from 31.5% to 57.0% for 'change of chewing side'. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. The paediatric flat foot proforma (p-FFP: improved and abridged following a reproducibility study

    Directory of Open Access Journals (Sweden)

    Nicholson Hollie

    2009-08-01

    Full Text Available Abstract Background Concern about a child's flat foot posture is a common reason for frequent clinical consultations for an array of health care and medical professionals. The recently developed paediatric flatfoot clinical-care pathway (FFP has provided an evidence based approach to diagnosis and management. The intra and inter-rater/measurer reliability of the FFP has been investigated in this study. Methods From a study population of 140 children aged seven to 10 years, a sample with flat feet was identified by screening with the Foot posture index (FPI-6. Subjects who scored ≥ 6 on the FPI-6 for both feet became the study's flat foot sample. A same subject, repeated measure research design was used for this study which examined the reliability of the FFP in 31 children aged seven to 10 years, as rated by three examiners. Results Approximately half of the items of the FFP showed less-than-desirable inter-rater reliability, arbitrarily set at the conventional 0.7 level (intra-class correlations. Removal of the unreliable items has produced a shorter; more relevant instrument designated the paediatric flat foot proforma (p-FFP. Conclusion The p-FFP is a reliable instrument for the assessment and resulting treatment actions for children with flat feet. Findings indicate that the simplified p-FFP is a reproducible instrument for the clinical assessment of flat foot in mid-childhood.

  8. Reproducibility of coronary calcification detection with electron-beam computed tomography

    International Nuclear Information System (INIS)

    Hernigou, A.; Challande, P.; Boudeville, J.C.; Sene, V.; Grataloup, C.; Plainfosse, M.

    1996-01-01

    If coronary calcification scores obtained with electron-beam computed tomography (EBT) were proved to be correlated to coronary atherosclerosis, the reproducibility of the technique had to be assessed before being useed for patient follow-up. A total of 150 patients, selected as a result of a cholesterol screening programme, were studied by EBT. Twelve contiguous 3-mm-thick transverse slices beginning on the proximal coronary arteries were obtained through the base of the heart. The amount of calcium was evaluated as the calcified area weighted by a coefficient depending on the density peak level. The value was expressed as a logarithmic scale. Intra-observer, inter-observer and inter-examination reproducibilities were calculated. They were 1.9, 1.3 and 7.2%, respectively. These results were good enough to allow the use of EBT for longitudinal studies. The influence of acquisition and calculation conditions on score computation were also analysed. (orig.)

  9. Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity

    Energy Technology Data Exchange (ETDEWEB)

    Ferraioli, Giovanna, E-mail: giovanna.ferraioli@unipv.it [Ultrasound Unit, Infectious Diseases Department, IRCCS San Matteo Hospital Foundation, University of Pavia, Via Taramelli 5, 27100 Pavia (Italy); Tinelli, Carmine, E-mail: ctinelli@smatteo.pv.it [Clinical Epidemiology and Biometric Unit, IRCCS San Matteo Hospital Foundation, Viale Golgi 19, 27100 Pavia (Italy); Zicchetti, Mabel, E-mail: mabel.zicchetti@unipv.it [Ultrasound Unit, Infectious Diseases Department, IRCCS San Matteo Hospital Foundation, University of Pavia, Via Taramelli 5, 27100 Pavia (Italy); Above, Elisabetta, E-mail: betta.above@gmail.com [Ultrasound Unit, Infectious Diseases Department, IRCCS San Matteo Hospital Foundation, University of Pavia, Via Taramelli 5, 27100 Pavia (Italy); Poma, Gianluigi, E-mail: gigi.poma@libero.it [Ultrasound Unit, Infectious Diseases Department, IRCCS San Matteo Hospital Foundation, University of Pavia, Via Taramelli 5, 27100 Pavia (Italy); Di Gregorio, Marta, E-mail: martadigregorio@virgilio.it [Ultrasound Unit, Infectious Diseases Department, IRCCS San Matteo Hospital Foundation, University of Pavia, Via Taramelli 5, 27100 Pavia (Italy); Filice, Carlo, E-mail: carfil@unipv.it [Ultrasound Unit, Infectious Diseases Department, IRCCS San Matteo Hospital Foundation, University of Pavia, Via Taramelli 5, 27100 Pavia (Italy)

    2012-11-15

    Objective: To evaluate the reproducibility of real-time shear wave elastography in assessing liver elasticity in healthy volunteers. Methods: Forty-two volunteers were studied in day 1. Shear wave elastography studies were performed by using the ultrasound system Aixplorer Trade-Mark-Sign (SuperSonic Imagine S.A., Aix-en-Provence, France) with a convex broadband probe. Measurements were carried by two operators, an expert (operator 1) and a novice (operator 2). Examinations were performed on the right lobe of the liver. Each operator performed 10 consecutive measurements in each volunteer. In a subset of volunteers (n = 18) measurements were performed twice on two different days (day 1 and day 2). Intraobserver and interobserver agreement were assessed by intraclass correlation coefficient. Results: Intraobserver agreement between measurements performed in the same subject in the same day (day 1 or day 2) showed intraclass correlation coefficient values of 0.95 (95% confidence interval, 0.93-0.98) and 0.93 (95% confidence interval, 0.90-0.96) for operator 1 and operator 2, respectively. Intraobserver agreement between measurements performed in the same subject in different days showed intraclass correlation coefficient values of 0.84 (95% confidence interval, 0.69-0.98) and 0.65 (95% confidence interval, 0.39-0.91) for operator 1 and operator 2, respectively. Interobserver agreement was 0.88 (95% confidence interval, 0.82-0.94). Conclusions: The results of this study show that shear wave elastography is a reliable and reproducible noninvasive method for the assessment of liver elasticity. Expert operator had higher reproducibility of measurements over time than novice operator.

  10. Reproducibility of mean nuclear volume and correlation with mean nuclear area in breast cancer

    DEFF Research Database (Denmark)

    Baak, J P; Ladekarl, M; Sørensen, Flemming Brandt

    1994-01-01

    reproducible and strongly correlated with nuclear vv assessed in the TOTAL. In invasive breast cancer assessments in the whole tumor section can be used if delineation of the measurement area cannot be done easily. In small areas with a limited number of nuclei (eg, microinvasive parts) MNA can be easier......Previous studies have shown that quantitative, histopathologic features obtained from a carefully selected area in the tumor section ("selective" approach) have a strong prognostic value in breast cancer. On the other hand, it was found that mean nuclear volume estimation in the whole area...... as to their intraobserver and interobserver reproducibility in 22 invasive breast cancer cases. The mean nuclear volume (nuclear vv) was assessed both in the most atypical area (AREA) (selected on morphologic criteria) and in the whole tumor section (TOTAL). Furthermore, the correlation with mean nuclear (profile) area...

  11. A multiparametric automatic method to monitor long-term reproducibility in digital mammography: results from a regional screening programme.

    Science.gov (United States)

    Gennaro, G; Ballaminut, A; Contento, G

    2017-09-01

    This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.

  12. Reproducibility of trabecular bone score with different scan modes using dual-energy X-ray absorptiometry: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Bandirali, Michele; Messina, Carmelo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Di Leo, Giovanni [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Pastor Lopez, Maria Juana; Ulivieri, Fabio M. [Servizio di Medicina Nucleare, Ospedale Maggiore, Mineralometria Ossea Computerizzata e Ambulatorio Malattie Metabolismo Minerale e Osseo, Milano (Italy); Mai, Alessandro [Universita degli Studi di Milano, Tecniche di Radiologia Medica, per Immagini e Radioterapia, Milano (Italy); Sardanelli, Francesco [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, San Donato Milanese (Italy)

    2014-08-12

    The trabecular bone score (TBS) accounts for the bone microarchitecture and is calculated on dual-energy X-ray absorptiometry (DXA). We estimated the reproducibility of the TBS using different scan modes compared to the reproducibility bone mineral density (BMD). A spine phantom was used with a Hologic QDR-Discovery A densitometer. For each scan mode [fast array, array, high definition (HD)], 25 scans were automatically performed without phantom repositioning; a further 25 scans were performed with phantom repositioning. For each scan, the TBS was obtained. The coefficient of variation (CoV) was calculated as the ratio between standard deviation and mean; percent least significant change (LSC%) as 2.8 x CoV; reproducibility as the complement to 100 % of LSC%. Differences among scan modes were assessed using ANOVA. Without phantom repositioning, the mean TBS (mm{sup -1}) was: 1.352 (fast array), 1.321 (array), and 1.360 (HD); with phantom repositioning, it was 1.345, 1.332, and 1.362, respectively. Reproducibility of the TBS without phantom repositioning was 97.7 % (fast array), 98.3 % (array), and 98.2 % (HD); with phantom repositioning, it was 97.9 %, 98.7 %, and 98.4 %, respectively. LSC% was ≤2.26 %. Differences among scan modes were all statistically significant (p ≤ 0.019). Reproducibility of BMD was 99.1 % with all scan modes, while LSC% was from 0.86 % to 0.91 %. Reproducibility error of the TBS was 2-3-fold higher than that of BMD. Although statistically significant, differences in TBS among scan modes were within the highest LSC%. Thus, the three scan modes can be considered interchangeable. (orig.)

  13. Assessment of Vert-3D repeatability and reproducibility for evaluating the scoliosis of children with different nutritional profiles

    Directory of Open Access Journals (Sweden)

    Juliana Adami Sedrez

    Full Text Available Abstract Introduction: The Vert-3D is a radiation-free system which offers a three-dimensional view of the back’s surface, providing a quantitative assessment of spinal curvatures. Objective: To verify the repeatability, inter-rater reproducibility, and correlation between Cobb angles and the results of the Vert-3D system version 1 in the evaluation of the front curvatures of the spine in children with different nutritional profiles. Methods: The sample was composed of 115 children who underwent posterior-anterior panoramic digital radiography of the spine and five evaluations with the Vert-3D system by three trained raters. Results: Version 1 of the Vert-3D system showed: (1 significant and moderate correlations of repeatability for arrows on the left (ICC between .54 to .83 and significant and moderate correlations for arrows on the right (ICC between .55 to .60 for only normal BMI; (2 significant correlations of inter-rater reproducibility for left arrows (ICC between .47 to .65, weak to moderate correlations for right arrows (ICC between .29 to .60, and no significance for obese samples; and (3 significant correlations ranging between .31 and .60 on the left side and non-significant correlations to the right side between Cobb angles and scoliosis arrows. Conclusion: High correlation levels solely on the left side decrease the possibility of system-use for the assessment of scoliosis.

  14. Reproducibility of ultrasonic testing

    International Nuclear Information System (INIS)

    Lecomte, J.-C.; Thomas, Andre; Launay, J.-P.; Martin, Pierre

    The reproducibility of amplitude quotations for both artificial and natural reflectors was studied for several combinations of instrument/search unit, all being of the same type. This study shows that in industrial inspection if a range of standardized equipment is used, a margin of error of about 6 decibels has to be taken into account (confidence interval of 95%). This margin is about 4 to 5 dB for natural or artificial defects located in the central area and about 6 to 7 dB for artificial defects located on the back surface. This lack of reproducibility seems to be attributable first to the search unit and then to the instrument and operator. These results were confirmed by analysis of calibration data obtained from 250 tests performed by 25 operators under shop conditions. The margin of error was higher than the 6 dB obtained in the study [fr

  15. Validity and reproducibility of a Spanish dietary history.

    Directory of Open Access Journals (Sweden)

    Pilar Guallar-Castillón

    Full Text Available To assess the validity and reproducibility of food and nutrient intake estimated with the electronic diet history of ENRICA (DH-E, which collects information on numerous aspects of the Spanish diet.The validity of food and nutrient intake was estimated using Pearson correlation coefficients between the DH-E and the mean of seven 24-hour recalls collected every 2 months over the previous year. The reproducibility was estimated using intraclass correlation coefficients between two DH-E made one year apart.The correlations coefficients between the DH-E and the mean of seven 24-hour recalls for the main food groups were cereals (r = 0.66, meat (r = 0.66, fish (r = 0.42, vegetables (r = 0.62 and fruits (r = 0.44. The mean correlation coefficient for all 15 food groups considered was 0.53. The correlations for macronutrients were: energy (r = 0.76, proteins (r= 0.58, lipids (r = 0.73, saturated fat (r = 0.73, monounsaturated fat (r = 0.59, polyunsaturated fat (r = 0.57, and carbohydrates (r = 0.66. The mean correlation coefficient for all 41 nutrients studied was 0.55. The intraclass correlation coefficient between the two DH-E was greater than 0.40 for most foods and nutrients.The DH-E shows good validity and reproducibility for estimating usual intake of foods and nutrients.

  16. [The Autocad system for planimetric study of the optic disc in glaucoma: technique and reproducibility study].

    Science.gov (United States)

    Sánchez Pérez, A; Honrubia López, F M; Larrosa Poves, J M; Polo Llorens, V; Melcon Sánchez-Frieras, B

    2001-09-01

    To develop a lens planimetry technique for the optic disc using AutoCAD. To determine variability magnitude of the optic disc morphological measurements. We employed AutoCAD R.14.0 Autodesk: image acquisition, contour delimitation by multiple lines fitting or ellipse adjustment, image sectorialization and measurements quantification (optic disc and excavation, vertical diameters, optic disc area, excavation area, neuroretinal sector area and Beta atrophy area). Intraimage or operator and interimage o total reproducibility was studied by coefficient of variability (CV) (n=10) in normal and myopic optic discs. This technique allows to obtain optic disc measurement in 5 to 10 minutes time. Total or interimage variability of measurements introduced by one observer presents CV range from 1.18-4.42. Operator or intraimage measurement presents CV range from 0.30-4.21. Optic disc contour delimitation by ellipse adjustment achieved better reproducibility results than multiple lines adjustment in all measurements. Computer assisted AutoCAD planimetry is an interactive method to analyse the optic disc, feasible to incorporate to clinical practice. Reproducibility results are comparable to other analyzers in quantification optic disc morphology. Ellipse adjustment improves results in optic disc contours delimitation.

  17. Three-dimensional surgical modelling with an open-source software protocol: study of precision and reproducibility in mandibular reconstruction with the fibula free flap.

    Science.gov (United States)

    Ganry, L; Quilichini, J; Bandini, C M; Leyder, P; Hersant, B; Meningaud, J P

    2017-08-01

    Very few surgical teams currently use totally independent and free solutions to perform three-dimensional (3D) surgical modelling for osseous free flaps in reconstructive surgery. This study assessed the precision and technical reproducibility of a 3D surgical modelling protocol using free open-source software in mandibular reconstruction with fibula free flaps and surgical guides. Precision was assessed through comparisons of the 3D surgical guide to the sterilized 3D-printed guide, determining accuracy to the millimetre level. Reproducibility was assessed in three surgical cases by volumetric comparison to the millimetre level. For the 3D surgical modelling, a difference of less than 0.1mm was observed. Almost no deformations (free flap modelling was between 0.1mm and 0.4mm, and the average precision of the complete reconstructed mandible was less than 1mm. The open-source software protocol demonstrated high accuracy without complications. However, the precision of the surgical case depends on the surgeon's 3D surgical modelling. Therefore, surgeons need training on the use of this protocol before applying it to surgical cases; this constitutes a limitation. Further studies should address the transfer of expertise. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Reproducibility study of [{sup 18}F]FPP(RGD){sub 2} uptake in murine models of human tumor xenografts

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Edwin; Liu, Shuangdong; Chin, Frederick; Cheng, Zhen [Stanford University, Molecular Imaging Program at Stanford, Department of Radiology, School of Medicine, Stanford, CA (United States); Gowrishankar, Gayatri; Yaghoubi, Shahriar [Stanford University, Molecular Imaging Program at Stanford, Department of Radiology, School of Medicine, Stanford, CA (United States); Stanford University, Molecular Imaging Program at Stanford, Department of Bioengineering, School of Medicine, Stanford, CA (United States); Wedgeworth, James Patrick [Stanford University, Molecular Imaging Program at Stanford, Department of Bioengineering, School of Medicine, Stanford, CA (United States); Berndorff, Dietmar; Gekeler, Volker [Bayer Schering Pharma AG, Global Drug Discovery, Berlin (Germany); Gambhir, Sanjiv S. [Stanford University, Molecular Imaging Program at Stanford, Department of Radiology, School of Medicine, Stanford, CA (United States); Stanford University, Molecular Imaging Program at Stanford, Department of Bioengineering, School of Medicine, Stanford, CA (United States); Canary Center at Stanford for Cancer Early Detection, Nuclear Medicine, Departments of Radiology and Bioengineering, Molecular Imaging Program at Stanford, Stanford, CA (United States)

    2011-04-15

    An {sup 18}F-labeled PEGylated arginine-glycine-aspartic acid (RGD) dimer [{sup 18}F]FPP(RGD){sub 2} has been used to image tumor {alpha}{sub v}{beta}{sub 3} integrin levels in preclinical and clinical studies. Serial positron emission tomography (PET) studies may be useful for monitoring antiangiogenic therapy response or for drug screening; however, the reproducibility of serial scans has not been determined for this PET probe. The purpose of this study was to determine the reproducibility of the integrin {alpha}{sub v}{beta}{sub 3}-targeted PET probe, [{sup 18}F ]FPP(RGD){sub 2} using small animal PET. Human HCT116 colon cancer xenografts were implanted into nude mice (n = 12) in the breast and scapular region and grown to mean diameters of 5-15 mm for approximately 2.5 weeks. A 3-min acquisition was performed on a small animal PET scanner approximately 1 h after administration of [{sup 18}F]FPP(RGD){sub 2} (1.9-3.8 MBq, 50-100 {mu}Ci) via the tail vein. A second small animal PET scan was performed approximately 6 h later after reinjection of the probe to assess for reproducibility. Images were analyzed by drawing an ellipsoidal region of interest (ROI) around the tumor xenograft activity. Percentage injected dose per gram (%ID/g) values were calculated from the mean or maximum activity in the ROIs. Coefficients of variation and differences in %ID/g values between studies from the same day were calculated to determine the reproducibility. The coefficient of variation (mean {+-}SD) for %ID{sub mean}/g and %ID{sub max}/g values between [{sup 18}F]FPP(RGD){sub 2} small animal PET scans performed 6 h apart on the same day were 11.1 {+-} 7.6% and 10.4 {+-} 9.3%, respectively. The corresponding differences in %ID{sub mean}/g and %ID{sub max}/g values between scans were -0.025 {+-} 0.067 and -0.039 {+-} 0.426. Immunofluorescence studies revealed a direct relationship between extent of {alpha}{sub {nu}}{beta}{sub 3} integrin expression in tumors and tumor vasculature

  19. Magni Reproducibility Example

    DEFF Research Database (Denmark)

    2016-01-01

    An example of how to use the magni.reproducibility package for storing metadata along with results from a computational experiment. The example is based on simulating the Mandelbrot set.......An example of how to use the magni.reproducibility package for storing metadata along with results from a computational experiment. The example is based on simulating the Mandelbrot set....

  20. Reproducibility of scoring emphysema by HRCT

    International Nuclear Information System (INIS)

    Malinen, A.; Partanen, K.; Rytkoenen, H.; Vanninen, R.; Erkinjuntti-Pekkanen, R.

    2002-01-01

    Purpose: We evaluated the reproducibility of three visual scoring methods of emphysema and compared these methods with pulmonary function tests (VC, DLCO, FEV1 and FEV%) among farmer's lung patients and farmers. Material and Methods: Three radiologists examined high-resolution CT images of farmer's lung patients and their matched controls (n=70) for chronic interstitial lung diseases. Intraobserver reproducibility and interobserver variability were assessed for three methods: severity, Sanders' (extent) and Sakai. Pulmonary function tests as spirometry and diffusing capacity were measured. Results: Intraobserver -values for all three methods were good (0.51-0.74). Interobserver varied from 0.35 to 0.72. The Sanders' and the severity methods correlated strongly with pulmonary function tests, especially DLCO and FEV1. Conclusion: The Sanders' method proved to be reliable in evaluating emphysema, in terms of good consistency of interpretation and good correlation with pulmonary function tests

  1. Validation of a method for accurate and highly reproducible quantification of brain dopamine transporter SPECT studies

    DEFF Research Database (Denmark)

    Jensen, Peter S; Ziebell, Morten; Skouboe, Glenna

    2011-01-01

    In nuclear medicine brain imaging, it is important to delineate regions of interest (ROIs) so that the outcome is both accurate and reproducible. The purpose of this study was to validate a new time-saving algorithm (DATquan) for accurate and reproducible quantification of the striatal dopamine t...... transporter (DAT) with appropriate radioligands and SPECT and without the need for structural brain scanning....

  2. Reproducibility of P-31 spectroscopic imaging of normal human myocardium

    International Nuclear Information System (INIS)

    Tavares, N.J.; Chew, W.; Auffermann, W.; Higgins, C.B.

    1988-01-01

    To assess reproducibility of P-31 MR spectroscopy of human myocardium, ten normal male volunteers were studied on two separate occasions. Spectra were acquired on a clinical 1.5-T MR imaging unit (Signa, General Electric) using a one-dimensional gated spectroscopic imaging sequence (matrix size, 32 X 256) over 20 minutes. Peaks in the adenosine triphosphate (ATP) region, phosphocreatine (PCR), phosphodiesters (PD), and peaks attributable to 2,3 diphosphoglycerate from blood were observed. Interindividual and intraindividual variability expressed as standard errors of the mean (mean +- SEM) were 1.54 +- 0.04 (variability among subjects) and 0.04 (variability between first and second studies) for PCR/β ATP; 0.97 +- 0.18 and 0.06 for PD/β ATP; and 0.62 +- 0.10 and 0.05 for PD/PCR, respectively. In conclusion, P-31 MR spectroscopy yields consistent and reproducible myocardial spectra that might be useful in the future for the evaluation and monitoring of cardiac disease

  3. Reporting to Improve Reproducibility and Facilitate Validity Assessment for Healthcare Database Studies V1.0

    NARCIS (Netherlands)

    Wang, Shirley V.; Schneeweiss, Sebastian; Berger, Marc L.; Brown, Jeffrey; de Vries, Frank; Douglas, Ian; Gagne, Joshua J.; Gini, Rosa; Klungel, Olaf; Mullins, C. Daniel; Nguyen, Michael D.; Rassen, Jeremy A.; Smeeth, Liam; Sturkenboom, Miriam C J M

    2017-01-01

    Purpose: Defining a study population and creating an analytic dataset from longitudinal healthcare databases involves many decisions. Our objective was to catalogue scientific decisions underpinning study execution that should be reported to facilitate replication and enable assessment of validity

  4. Reporting to Improve Reproducibility and Facilitate Validity Assessment for Healthcare Database Studies V1.0

    NARCIS (Netherlands)

    Wang, Shirley V.; Schneeweiss, Sebastian; Berger, Marc L.; Brown, Jeffrey; de Vries, Frank|info:eu-repo/dai/nl/303546670; Douglas, Ian; Gagne, Joshua J.; Gini, Rosa; Klungel, Olaf|info:eu-repo/dai/nl/181447649; Mullins, C. Daniel; Nguyen, Michael D.; Rassen, Jeremy A.; Smeeth, Liam; Sturkenboom, Miriam C J M

    2017-01-01

    Purpose Defining a study population and creating an analytic dataset from longitudinal healthcare databases involves many decisions. Our objective was to catalogue scientific decisions underpinning study execution that should be reported to facilitate replication and enable assessment of validity of

  5. ROCS: a Reproducibility Index and Confidence Score for Interaction Proteomics Studies

    Directory of Open Access Journals (Sweden)

    Dazard Jean-Eudes

    2012-06-01

    it to five previously published AP-MS experiments, each containing well characterized protein interactions, allowing for systematic benchmarking of ROCS. We show that our method may be used on its own to make accurate identification of specific, biologically relevant protein-protein interactions, or in combination with other AP-MS scoring methods to significantly improve inferences. Conclusions Our method addresses important issues encountered in AP-MS datasets, making ROCS a very promising tool for this purpose, either on its own or in conjunction with other methods. We anticipate that our methodology may be used more generally in proteomics studies and databases, where experimental reproducibility issues arise. The method is implemented in the R language, and is available as an R package called “ROCS”, freely available from the CRAN repository http://cran.r-project.org/.

  6. Reproducibility of LiF:Mg, Cup thermoluminescent dosimeter on kilo voltage and megavoltage photon beam using different preheat rate:A glow curve study

    International Nuclear Information System (INIS)

    Mohd Fahmi Mohd Yusof; Robert, T.S.B.; Puteri Norkhatijah Abdul Hamid; Nor Shazleen Abdul Shukor; Mohd Sazarman Mohd Salleh

    2013-01-01

    Full-text: Post-irradiation annealing or preheat of the LiF based TLD prior readout is commonly practiced for routine dosimetry to eliminate low temperature glow peaks. The aim of this study is to determine the effect of different preheating rate technique prior readout on the reproducibility and glow curve structure of LiF:Mg, Cu, P or TLD-1OOH exposed to low (109kVp) energy and high energy (6MV) photon beam. TLD chips were read after 24 hours of irradiation with three different preheat techniques; no preheat, low preheat rate (100 degree Celsius/ 10 minutes) and high preheat rate (135 degree Celsius/ 10 seconds) and reproducibility of TL signals were assessed in term of Standard Deviation (SD) and glow curve peaks. The high preheat rate technique was the most reproducible method for low energy photon with 1.05 % of mean reproducibility followed by low preheat rate (1.16 %) and no-preheat (1.33 %) techniques. The high preheat rate techniques was also the most reproducible method for high energy photon with 0.767 % of mean reproducibility as compared to low preheat rate (1.281 %). However the high preheat technique record highest TL signal lost with 10.35 % and 6.04 % for 24 and 72 hours of delayed TLD readout with respectively compared to 9.27 % and 4.51 % for 24 and 72 hours by low preheat rate. The low preheat was found to be optimal to eliminate low peaks (peak 1 and 2) but enable to remove peak 3 as it was shifted up word to combine with the main peak 4 of TL glow peak. It can be concluded that the reproducibility and structure of glow curve was strongly influenced by preheat technique prior readout. (author)

  7. Quantized correlation coefficient for measuring reproducibility of ChIP-chip data

    Directory of Open Access Journals (Sweden)

    Kuroda Mitzi I

    2010-07-01

    Full Text Available Abstract Background Chromatin immunoprecipitation followed by microarray hybridization (ChIP-chip is used to study protein-DNA interactions and histone modifications on a genome-scale. To ensure data quality, these experiments are usually performed in replicates, and a correlation coefficient between replicates is used often to assess reproducibility. However, the correlation coefficient can be misleading because it is affected not only by the reproducibility of the signal but also by the amount of binding signal present in the data. Results We develop the Quantized correlation coefficient (QCC that is much less dependent on the amount of signal. This involves discretization of data into set of quantiles (quantization, a merging procedure to group the background probes, and recalculation of the Pearson correlation coefficient. This procedure reduces the influence of the background noise on the statistic, which then properly focuses more on the reproducibility of the signal. The performance of this procedure is tested in both simulated and real ChIP-chip data. For replicates with different levels of enrichment over background and coverage, we find that QCC reflects reproducibility more accurately and is more robust than the standard Pearson or Spearman correlation coefficients. The quantization and the merging procedure can also suggest a proper quantile threshold for separating signal from background for further analysis. Conclusions To measure reproducibility of ChIP-chip data correctly, a correlation coefficient that is robust to the amount of signal present should be used. QCC is one such measure. The QCC statistic can also be applied in a variety of other contexts for measuring reproducibility, including analysis of array CGH data for DNA copy number and gene expression data.

  8. Quantized correlation coefficient for measuring reproducibility of ChIP-chip data.

    Science.gov (United States)

    Peng, Shouyong; Kuroda, Mitzi I; Park, Peter J

    2010-07-27

    Chromatin immunoprecipitation followed by microarray hybridization (ChIP-chip) is used to study protein-DNA interactions and histone modifications on a genome-scale. To ensure data quality, these experiments are usually performed in replicates, and a correlation coefficient between replicates is used often to assess reproducibility. However, the correlation coefficient can be misleading because it is affected not only by the reproducibility of the signal but also by the amount of binding signal present in the data. We develop the Quantized correlation coefficient (QCC) that is much less dependent on the amount of signal. This involves discretization of data into set of quantiles (quantization), a merging procedure to group the background probes, and recalculation of the Pearson correlation coefficient. This procedure reduces the influence of the background noise on the statistic, which then properly focuses more on the reproducibility of the signal. The performance of this procedure is tested in both simulated and real ChIP-chip data. For replicates with different levels of enrichment over background and coverage, we find that QCC reflects reproducibility more accurately and is more robust than the standard Pearson or Spearman correlation coefficients. The quantization and the merging procedure can also suggest a proper quantile threshold for separating signal from background for further analysis. To measure reproducibility of ChIP-chip data correctly, a correlation coefficient that is robust to the amount of signal present should be used. QCC is one such measure. The QCC statistic can also be applied in a variety of other contexts for measuring reproducibility, including analysis of array CGH data for DNA copy number and gene expression data.

  9. Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity

    International Nuclear Information System (INIS)

    Ferraioli, Giovanna; Tinelli, Carmine; Zicchetti, Mabel; Above, Elisabetta; Poma, Gianluigi; Di Gregorio, Marta; Filice, Carlo

    2012-01-01

    Objective: To evaluate the reproducibility of real-time shear wave elastography in assessing liver elasticity in healthy volunteers. Methods: Forty-two volunteers were studied in day 1. Shear wave elastography studies were performed by using the ultrasound system Aixplorer™ (SuperSonic Imagine S.A., Aix-en-Provence, France) with a convex broadband probe. Measurements were carried by two operators, an expert (operator 1) and a novice (operator 2). Examinations were performed on the right lobe of the liver. Each operator performed 10 consecutive measurements in each volunteer. In a subset of volunteers (n = 18) measurements were performed twice on two different days (day 1 and day 2). Intraobserver and interobserver agreement were assessed by intraclass correlation coefficient. Results: Intraobserver agreement between measurements performed in the same subject in the same day (day 1 or day 2) showed intraclass correlation coefficient values of 0.95 (95% confidence interval, 0.93–0.98) and 0.93 (95% confidence interval, 0.90–0.96) for operator 1 and operator 2, respectively. Intraobserver agreement between measurements performed in the same subject in different days showed intraclass correlation coefficient values of 0.84 (95% confidence interval, 0.69–0.98) and 0.65 (95% confidence interval, 0.39–0.91) for operator 1 and operator 2, respectively. Interobserver agreement was 0.88 (95% confidence interval, 0.82–0.94). Conclusions: The results of this study show that shear wave elastography is a reliable and reproducible noninvasive method for the assessment of liver elasticity. Expert operator had higher reproducibility of measurements over time than novice operator.

  10. Reproducibility of ECG-gated Ultrasound Diameter Assessment of Small Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Bredahl, K; Eldrup, N; Meyer, C

    2013-01-01

    No standardised ultrasound procedure to obtain reliable growth estimates for abdominal aortic aneurysms (AAA) is currently available. We investigated the feasibility and reproducibility of a novel approach controlling for a combination of vessel wall delineation and cardiac cycle variation....

  11. OECD validation study to assess intra- and inter-laboratory reproducibility of the zebrafish embryo toxicity test for acute aquatic toxicity testing.

    Science.gov (United States)

    Busquet, François; Strecker, Ruben; Rawlings, Jane M; Belanger, Scott E; Braunbeck, Thomas; Carr, Gregory J; Cenijn, Peter; Fochtman, Przemyslaw; Gourmelon, Anne; Hübler, Nicole; Kleensang, André; Knöbel, Melanie; Kussatz, Carola; Legler, Juliette; Lillicrap, Adam; Martínez-Jerónimo, Fernando; Polleichtner, Christian; Rzodeczko, Helena; Salinas, Edward; Schneider, Katharina E; Scholz, Stefan; van den Brandhof, Evert-Jan; van der Ven, Leo T M; Walter-Rohde, Susanne; Weigt, Stefan; Witters, Hilda; Halder, Marlies

    2014-08-01

    The OECD validation study of the zebrafish embryo acute toxicity test (ZFET) for acute aquatic toxicity testing evaluated the ZFET reproducibility by testing 20 chemicals at 5 different concentrations in 3 independent runs in at least 3 laboratories. Stock solutions and test concentrations were analytically confirmed for 11 chemicals. Newly fertilised zebrafish eggs (20/concentration and control) were exposed for 96h to chemicals. Four apical endpoints were recorded daily as indicators of acute lethality: coagulation of the embryo, lack of somite formation, non-detachment of the tail bud from the yolk sac and lack of heartbeat. Results (LC50 values for 48/96h exposure) show that the ZFET is a robust method with a good intra- and inter-laboratory reproducibility (CV30%) for some very toxic or volatile chemicals, and chemicals tested close to their limit of solubility. The ZFET is now available as OECD Test Guideline 236. Considering the high predictive capacity of the ZFET demonstrated by Belanger et al. (2013) in their retrospective analysis of acute fish toxicity and fish embryo acute toxicity data, the ZFET is ready to be considered for acute fish toxicity for regulatory purposes. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Studies of the reproducibility, acquisition and analysis of gastric emptying studies in pediatric population

    International Nuclear Information System (INIS)

    Yoo, J.H.K.; Rosen, P.R.

    1984-01-01

    The analysis, reproducibility and acquisition of gastric emptying data in a pediatric population was evaluated by obtaining data simultaneously with anterior and posterior gamma camera detectors, repetitive studies in patients and by the use of power exponential analysis, in addition to conventional monoexponential methodology. 13 patients with a variety of gastroesophageal pathologies were studied with simultaneous anterior and posterior gamma camera data acquisition. Excluding 4 subjects with substantial emesis, there was no statistical difference in data obtained anteriorly and posteriorly. The anterior scan in general revealed more rapid initial emptying compared to the posterior scan, resulting in a smaller shape factor (S) when power exponential function analysis was employed. T1/2 using either simple monoexponential or power exponential calculations showed no difference for data obtained anteriorly or posteriorly. T3/4 showed larger values in posteriorly obtained data as compared to anteriorly obtained data. 7 patients had repetitive studies performed at intervals from 1-9 days. Data so obtained showed no statistical difference in T1/2, T3/4 or S derived, either by single exponential or power exponential. The authors conclude therefore that gastric emptying data in a pediatric age group appears to be reproducible in repetitive studies. There appears to be no difference in data acquired anteriorly or posteriorly. The utilization of a power exponential analysis of gastric emptying data may augment the description of data by providing a quantitative expression of a multiexponential function

  13. Reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    McGill Laura-Ann

    2012-12-01

    Full Text Available Abstract Background Myocardial disarray is an important histological feature of hypertrophic cardiomyopathy (HCM which has been studied post-mortem, but its in-vivo prevalence and extent is unknown. Cardiac Diffusion Tensor Imaging (cDTI provides information on mean intravoxel myocyte orientation and potentially myocardial disarray. Recent technical advances have improved in-vivo cDTI, and the aim of this study was to assess the interstudy reproducibility of quantitative in-vivo cDTI in patients with HCM. Methods and results A stimulated-echo single-shot-EPI sequence with zonal excitation and parallel imaging was implemented. Ten patients with HCM were each scanned on 2 different days. For each scan 3 short axis mid-ventricular slices were acquired with cDTI at end systole. Fractional anisotropy (FA, mean diffusivity (MD, and helix angle (HA maps were created using a cDTI post-processing platform developed in-house. The mean ± SD global FA was 0.613 ± 0.044, MD was 0.750 ± 0.154 × 10-3 mm2/s and HA was epicardium −34.3 ± 7.6°, mesocardium 3.5 ± 6.9° and endocardium 38.9 ± 8.1°. Comparison of initial and repeat studies showed global interstudy reproducibility for FA (SD = ± 0.045, Coefficient of Variation (CoV = 7.2%, MD (SD = ± 0.135 × 10-3 mm2/s, CoV = 18.6% and HA (epicardium SD = ± 4.8°; mesocardium SD = ± 3.4°; endocardium SD = ± 2.9°. Reproducibility of FA was superior to MD (p = 0.003. Global MD was significantly higher in the septum than the reference lateral wall (0.784 ± 0.188 vs 0.750 ± 0.154 x10-3 mm2/s, p  Conclusions To the best of our knowledge, this is the first study to assess the interstudy reproducibility of DTI in the human HCM heart in-vivo and the largest cDTI study in HCM to date. Our results show good reproducibility of FA, MD and HA which indicates that current technology yields robust in-vivo measurements that have potential clinical value. The

  14. Does an eye-hand coordination test have added value as part of talent identification in table tennis? A validity and reproducibility study.

    Science.gov (United States)

    Faber, Irene R; Oosterveld, Frits G J; Nijhuis-Van der Sanden, Maria W G

    2014-01-01

    This study investigated the added value, i.e. discriminative and concurrent validity and reproducibility, of an eye-hand coordination test relevant to table tennis as part of talent identification. Forty-three table tennis players (7-12 years) from national (n = 13), regional (n = 11) and local training centres (n = 19) participated. During the eye-hand coordination test, children needed to throw a ball against a vertical positioned table tennis table with one hand and to catch the ball correctly with the other hand as frequently as possible in 30 seconds. Four different test versions were assessed varying the distance to the table (1 or 2 meter) and using a tennis or table tennis ball. 'Within session' reproducibility was estimated for the two attempts of the initial tests and ten youngsters were retested after 4 weeks to estimate 'between sessions' reproducibility. Validity analyses using age as covariate showed that players from the national and regional centres scored significantly higher than players from the local centre in all test versions (ptalent identification appears to be the version with a table tennis ball at 1 meter regarding the psychometric characteristics evaluated. Longitudinal studies are necessary to evaluate the predictive value of this test.

  15. International Interlaboratory Digital PCR Study Demonstrating High Reproducibility for the Measurement of a Rare Sequence Variant.

    Science.gov (United States)

    Whale, Alexandra S; Devonshire, Alison S; Karlin-Neumann, George; Regan, Jack; Javier, Leanne; Cowen, Simon; Fernandez-Gonzalez, Ana; Jones, Gerwyn M; Redshaw, Nicholas; Beck, Julia; Berger, Andreas W; Combaret, Valérie; Dahl Kjersgaard, Nina; Davis, Lisa; Fina, Frederic; Forshew, Tim; Fredslund Andersen, Rikke; Galbiati, Silvia; González Hernández, Álvaro; Haynes, Charles A; Janku, Filip; Lacave, Roger; Lee, Justin; Mistry, Vilas; Pender, Alexandra; Pradines, Anne; Proudhon, Charlotte; Saal, Lao H; Stieglitz, Elliot; Ulrich, Bryan; Foy, Carole A; Parkes, Helen; Tzonev, Svilen; Huggett, Jim F

    2017-02-07

    This study tested the claim that digital PCR (dPCR) can offer highly reproducible quantitative measurements in disparate laboratories. Twenty-one laboratories measured four blinded samples containing different quantities of a KRAS fragment encoding G12D, an important genetic marker for guiding therapy of certain cancers. This marker is challenging to quantify reproducibly using quantitative PCR (qPCR) or next generation sequencing (NGS) due to the presence of competing wild type sequences and the need for calibration. Using dPCR, 18 laboratories were able to quantify the G12D marker within 12% of each other in all samples. Three laboratories appeared to measure consistently outlying results; however, proper application of a follow-up analysis recommendation rectified their data. Our findings show that dPCR has demonstrable reproducibility across a large number of laboratories without calibration. This could enable the reproducible application of molecular stratification to guide therapy and, potentially, for molecular diagnostics.

  16. Validity and reproducibility of a food frequency questionnaire for dietary factors related to colorectal cancer

    OpenAIRE

    Tollosa, Daniel Nigusse; Van Camp, John; Huybrechts, Inge; Huybregts, Lieven; Van Loco, Joris; De Smet, Stefaan; Sterck, Ellen; Rabâi, Céline; Van Hecke, Thomas; Vanhaecke, Lynn; Vossen, Els; Peeters, Marc; Lachat, Carl

    2017-01-01

    Dietary factors play a major role in the development of colorectal cancer. This study evaluated the reproducibility and validity of a 109-food item Food Frequency Questionnaire (FFQ) to measure the consumption of foods and nutrients related to the development of colorectal cancer in a population aged ≥50 years in Flanders, Belgium. A semi-quantitative FFQ was administered two times in a period of two weeks to evaluate reproducibility (FFQ1 and FFQ2). The validity of the FFQ was assessed by co...

  17. Reproducibility of wrist home blood pressure measurement with position sensor and automatic data storage

    Directory of Open Access Journals (Sweden)

    Nickenig Georg

    2009-05-01

    Full Text Available Abstract Background Wrist blood pressure (BP devices have physiological limits with regards to accuracy, therefore they were not preferred for home BP monitoring. However some wrist devices have been successfully validated using etablished validation protocols. Therefore this study assessed the reproducibility of wrist home BP measurement with position sensor and automatic data storage. Methods To compare the reproducibility of three different(BP measurement methods: 1 office BP, 2 home BP (Omron wrist device HEM- 637 IT with position sensor, 3 24-hour ambulatory BP(24-h ABPM (ABPM-04, Meditech, Hunconventional sphygmomanometric office BP was measured on study days 1 and 7, 24-h ABPM on study days 7 and 14 and home BP between study days 1 and 7 and between study days 8 and 14 in 69 hypertensive and 28 normotensive subjects. The correlation coeffcient of each BP measurement method with echocardiographic left ventricular mass index was analyzed. The schedule of home readings was performed according to recently published European Society of Hypertension (ESH- guidelines. Results The reproducibility of home BP measurement analyzed by the standard deviation as well as the squared differeces of mean individual differences between the respective BP measurements was significantly higher than the reproducibility of office BP (p Conclusion The short-term reproducibility of home BP measurement with the Omron HEM-637 IT wrist device was superior to the reproducibility of office BP and 24- h ABPM measurement. Furthermore, home BP with the wrist device showed similar correlations to targed organ damage as recently reported for upper arm devices. Although wrist devices have to be used cautious and with defined limitations, the use of validated devices with position sensor according to recently recommended measurement schedules might have the potential to be used for therapy monitoring.

  18. Audiovisual biofeedback improves diaphragm motion reproducibility in MRI

    Science.gov (United States)

    Kim, Taeho; Pollock, Sean; Lee, Danny; O’Brien, Ricky; Keall, Paul

    2012-01-01

    Purpose: In lung radiotherapy, variations in cycle-to-cycle breathing results in four-dimensional computed tomography imaging artifacts, leading to inaccurate beam coverage and tumor targeting. In previous studies, the effect of audiovisual (AV) biofeedback on the external respiratory signal reproducibility has been investigated but the internal anatomy motion has not been fully studied. The aim of this study is to test the hypothesis that AV biofeedback improves diaphragm motion reproducibility of internal anatomy using magnetic resonance imaging (MRI). Methods: To test the hypothesis 15 healthy human subjects were enrolled in an ethics-approved AV biofeedback study consisting of two imaging sessions spaced ∼1 week apart. Within each session MR images were acquired under free breathing and AV biofeedback conditions. The respiratory signal to the AV biofeedback system utilized optical monitoring of an external marker placed on the abdomen. Synchronously, serial thoracic 2D MR images were obtained to measure the diaphragm motion using a fast gradient-recalled-echo MR pulse sequence in both coronal and sagittal planes. The improvement in the diaphragm motion reproducibility using the AV biofeedback system was quantified by comparing cycle-to-cycle variability in displacement, respiratory period, and baseline drift. Additionally, the variation in improvement between the two sessions was also quantified. Results: The average root mean square error (RMSE) of diaphragm cycle-to-cycle displacement was reduced from 2.6 mm with free breathing to 1.6 mm (38% reduction) with the implementation of AV biofeedback (p-value biofeedback (p-value biofeedback (p-value = 0.012). The diaphragm motion reproducibility improvements with AV biofeedback were consistent with the abdominal motion reproducibility that was observed from the external marker motion variation. Conclusions: This study was the first to investigate the potential of AV biofeedback to improve the motion

  19. Reproducibility of the Pleth Variability Index in premature infants

    NARCIS (Netherlands)

    Den Boogert, W.J. (Wilhelmina J.); H.A. van Elteren (Hugo); T.G. Goos (Tom); I.K.M. Reiss (Irwin); R.C.J. de Jonge (Rogier); V.J. van den Berg (Victor J.)

    2017-01-01

    textabstractThe aim was to assess the reproducibility of the Pleth Variability Index (PVI), developed for non-invasive monitoring of peripheral perfusion, in preterm neonates below 32 weeks of gestational age. Three PVI measurements were consecutively performed in stable, comfortable preterm

  20. Reproducibility of scoring emphysema by HRCT

    Energy Technology Data Exchange (ETDEWEB)

    Malinen, A.; Partanen, K.; Rytkoenen, H.; Vanninen, R. [Kuopio Univ. Hospital (Finland). Dept. of Clinical Radiology; Erkinjuntti-Pekkanen, R. [Kuopio Univ. Hospital (Finland). Dept. of Pulmonary Diseases

    2002-04-01

    Purpose: We evaluated the reproducibility of three visual scoring methods of emphysema and compared these methods with pulmonary function tests (VC, DLCO, FEV1 and FEV%) among farmer's lung patients and farmers. Material and Methods: Three radiologists examined high-resolution CT images of farmer's lung patients and their matched controls (n=70) for chronic interstitial lung diseases. Intraobserver reproducibility and interobserver variability were assessed for three methods: severity, Sanders' (extent) and Sakai. Pulmonary function tests as spirometry and diffusing capacity were measured. Results: Intraobserver -values for all three methods were good (0.51-0.74). Interobserver varied from 0.35 to 0.72. The Sanders' and the severity methods correlated strongly with pulmonary function tests, especially DLCO and FEV1. Conclusion: The Sanders' method proved to be reliable in evaluating emphysema, in terms of good consistency of interpretation and good correlation with pulmonary function tests.

  1. Reproducibility of a 3-dimensional gyroscope in measuring shoulder anteflexion and abduction

    Directory of Open Access Journals (Sweden)

    Penning Ludo I F

    2012-07-01

    Full Text Available Abstract Background Few studies have investigated the use of a 3-dimensional gyroscope for measuring the range of motion (ROM in the impaired shoulder. Reproducibility of digital inclinometer and visual estimation is poor. This study aims to investigate the reproducibility of a tri axial gyroscope in measurement of anteflexion, abduction and related rotations in the impaired shoulder. Methods Fifty-eight patients with either subacromial impingement (27 or osteoarthritis of the shoulder (31 participated. Active anteflexion, abduction and related rotations were measured with a tri axial gyroscope according to a test retest protocol. Severity of shoulder impairment and patient perceived pain were assessed by the Disability of Arm Shoulder and Hand score (DASH and the Visual Analogue Scale (VAS. VAS scores were recorded before and after testing. Results In two out of three hospitals patients with osteoarthritis (n = 31 were measured, in the third hospital patients with subacromial impingement (n = 27. There were significant differences among hospitals for the VAS and DASH scores measured before and after testing. The mean differences between the test and retest means for anteflexion were −6 degrees (affected side, 9 (contralateral side and for abduction 15 degrees (affected side and 10 degrees (contralateral side. Bland & Altman plots showed that the confidence intervals for the mean differences fall within −6 up to 15 degrees, individual test - retest differences could exceed these limits. A simulation according to ‘Generalizability Theory’ produces very good coefficients for anteflexion and related rotation as a comprehensive measure of reproducibility. Optimal reproducibility is achieved with 2 repetitions for anteflexion. Conclusions Measurements were influenced by patient perceived pain. Differences in VAS and DASH might be explained by different underlying pathology. These differences in shoulder pathology however did not alter

  2. Determinants, reproducibility, and seasonal variation of ergosterol levels in house dust.

    Science.gov (United States)

    Leppänen, H K; Nevalainen, A; Vepsäläinen, A; Roponen, M; Täubel, M; Laine, O; Rantakokko, P; von Mutius, E; Pekkanen, J; Hyvärinen, A

    2014-06-01

    This study aimed to clarify the determinants that affect the concentrations of ergosterol and viable fungi in house dust and to examine the seasonal variation and reproducibility of ergosterol concentrations indoors. In studying the determinants, dust samples from living room floors and vacuum cleaner dust bags were collected from 107 farming and 105 non-farming homes. Ergosterol levels were determined with gas chromatography-mass spectrometry,and the dust bag dust was cultivated for enumeration of fungal genera. Lifestyle and environmental factors, for example using of the fireplace, and visible mold observations in homes, explained 20–26% of the variation of fungal concentrations. For the reproducibility study, samples were collected from five urban homes in four different seasons. The reproducibility of ergosterol determinations within a sample was excellent (ICC = 89.8) for floor dust and moderate (ICC = 63.8) for dust bag dust, but poor when sampling the same home throughout a year (ICC = 31.3 and 12.6, respectively) due to large temporal variation in ergosterol concentrations. In conclusion, environmental characteristics only partially predicted the variation of fungal concentrations. Based on these studies, we recommend repeated sampling of dust over time if one seeks to adequately describe overall fungal levels and exposure in a home. This study shows that levels of ergosterol and viable fungi in house dust are related to visible mold observations. Only 20% of the variation in fungal levels can be explained with questionnaires, and therefore, environmental samples need to be taken in addition. Reproducibility of ergosterol determination was excellent for floor dust, and thus, ergosterol measurements from floor dust samples could be suitable for assessing the fungal load in building investigations. The temporal variation needs to be taken into account when describing the ergosterol concentration of urban homes.

  3. Development of a Three-Dimensional Hand Model Using Three-Dimensional Stereophotogrammetry: Assessment of Image Reproducibility.

    Directory of Open Access Journals (Sweden)

    Inge A Hoevenaren

    Full Text Available Using three-dimensional (3D stereophotogrammetry precise images and reconstructions of the human body can be produced. Over the last few years, this technique is mainly being developed in the field of maxillofacial reconstructive surgery, creating fusion images with computed tomography (CT data for precise planning and prediction of treatment outcome. Though, in hand surgery 3D stereophotogrammetry is not yet being used in clinical settings.A total of 34 three-dimensional hand photographs were analyzed to investigate the reproducibility. For every individual, 3D photographs were captured at two different time points (baseline T0 and one week later T1. Using two different registration methods, the reproducibility of the methods was analyzed. Furthermore, the differences between 3D photos of men and women were compared in a distance map as a first clinical pilot testing our registration method.The absolute mean registration error for the complete hand was 1.46 mm. This reduced to an error of 0.56 mm isolating the region to the palm of the hand. When comparing hands of both sexes, it was seen that the male hand was larger (broader base and longer fingers than the female hand.This study shows that 3D stereophotogrammetry can produce reproducible images of the hand without harmful side effects for the patient, so proving to be a reliable method for soft tissue analysis. Its potential use in everyday practice of hand surgery needs to be further explored.

  4. Reproducibility of Single-Pulse, Paired-Pulse, and Intermittent Theta-Burst TMS Measures in Healthy Aging, Type-2 Diabetes, and Alzheimer’s Disease

    Directory of Open Access Journals (Sweden)

    Peter J. Fried

    2017-08-01

    Full Text Available Background: Transcranial magnetic stimulation (TMS can be used to assess neurophysiology and the mechanisms of cortical brain plasticity in humans in vivo. As the use of these measures in specific populations (e.g., Alzheimer’s disease; AD increases, it is critical to understand their reproducibility (i.e., test–retest reliability in the populations of interest.Objective: Reproducibility of TMS measures was evaluated in older adults, including healthy, AD, and Type-2 diabetes mellitus (T2DM groups.Methods: Participants received two identical neurophysiological assessments within a year including motor thresholds, baseline motor evoked potentials (MEPs, short- and long-interval intracortical inhibition (SICI, LICI and intracortical facilitation (ICF, and MEP changes following intermittent theta-burst stimulation (iTBS. Cronbach’s α coefficients were calculated to assess reproducibility. Multiple linear regression analyses were used to investigate factors related to intraindividual variability.Results: Reproducibility was highest for motor thresholds, followed by baseline MEPs, SICI and LICI, and was lowest for ICF and iTBS aftereffects. The AD group tended to show higher reproducibility than T2DM or controls. Intraindividual variability of baseline MEPs was related to age and variability of RMT, while the intraindividual variability in post-iTBS measures was related to baseline MEP variability, intervisit duration, and Brain-derived neurotrophic factor (BDNF polymorphism.Conclusion: Increased reproducibility in AD may reflect pathophysiological declines in the efficacy of neuroplastic mechanisms. Reproducibility of iTBS aftereffects can be improved by keeping baseline MEPs consistent, controlling for BDNF genotype, and waiting at least a week between visits.Significance: These findings provide the first direct assessment of reproducibility of TMS measures in older clinical populations. Reproducibility coefficients may be used to adjust

  5. Systematic heterogenization for better reproducibility in animal experimentation.

    Science.gov (United States)

    Richter, S Helene

    2017-08-31

    The scientific literature is full of articles discussing poor reproducibility of findings from animal experiments as well as failures to translate results from preclinical animal studies to clinical trials in humans. Critics even go so far as to talk about a "reproducibility crisis" in the life sciences, a novel headword that increasingly finds its way into numerous high-impact journals. Viewed from a cynical perspective, Fett's law of the lab "Never replicate a successful experiment" has thus taken on a completely new meaning. So far, poor reproducibility and translational failures in animal experimentation have mostly been attributed to biased animal data, methodological pitfalls, current publication ethics and animal welfare constraints. More recently, the concept of standardization has also been identified as a potential source of these problems. By reducing within-experiment variation, rigorous standardization regimes limit the inference to the specific experimental conditions. In this way, however, individual phenotypic plasticity is largely neglected, resulting in statistically significant but possibly irrelevant findings that are not reproducible under slightly different conditions. By contrast, systematic heterogenization has been proposed as a concept to improve representativeness of study populations, contributing to improved external validity and hence improved reproducibility. While some first heterogenization studies are indeed very promising, it is still not clear how this approach can be transferred into practice in a logistically feasible and effective way. Thus, further research is needed to explore different heterogenization strategies as well as alternative routes toward better reproducibility in animal experimentation.

  6. The Economics of Reproducibility in Preclinical Research.

    Directory of Open Access Journals (Sweden)

    Leonard P Freedman

    2015-06-01

    Full Text Available Low reproducibility rates within life science research undermine cumulative knowledge production and contribute to both delays and costs of therapeutic drug development. An analysis of past studies indicates that the cumulative (total prevalence of irreproducible preclinical research exceeds 50%, resulting in approximately US$28,000,000,000 (US$28B/year spent on preclinical research that is not reproducible-in the United States alone. We outline a framework for solutions and a plan for long-term improvements in reproducibility rates that will help to accelerate the discovery of life-saving therapies and cures.

  7. [Natural head position's reproducibility on photographs].

    Science.gov (United States)

    Eddo, Marie-Line; El Hayeck, Émilie; Hoyeck, Maha; Khoury, Élie; Ghoubril, Joseph

    2017-12-01

    The purpose of this study is to evaluate the reproducibility of natural head position with time on profile photographs. Our sample is composed of 96 students (20-30 years old) at the department of dentistry of Saint Joseph University in Beirut. Two profile photographs were taken in natural head position about a week apart. No significant differences were found between T0 and T1 (E = 1.065°). Many studies confirmed this reproducibility with time. Natural head position can be adopted as an orientation for profile photographs in orthodontics. © EDP Sciences, SFODF, 2017.

  8. Methodological approach for the assessment of ultrasound reproducibility of cardiac structure and function: a proposal of the study group of Echocardiography of the Italian Society of Cardiology (Ultra Cardia SIC) Part I

    Science.gov (United States)

    2011-01-01

    When applying echo-Doppler imaging for either clinical or research purposes it is very important to select the most adequate modality/technology and choose the most reliable and reproducible measurements. Quality control is a mainstay to reduce variability among institutions and operators and must be obtained by using appropriate procedures for data acquisition, storage and interpretation of echo-Doppler data. This goal can be achieved by employing an echo core laboratory (ECL), with the responsibility for standardizing image acquisition processes (performed at the peripheral echo-labs) and analysis (by monitoring and optimizing the internal intra- and inter-reader variability of measurements). Accordingly, the Working Group of Echocardiography of the Italian Society of Cardiology decided to design standardized procedures for imaging acquisition in peripheral laboratories and reading procedures and to propose a methodological approach to assess the reproducibility of echo-Doppler parameters of cardiac structure and function by using both standard and advanced technologies. A number of cardiologists experienced in cardiac ultrasound was involved to set up an ECL available for future studies involving complex imaging or including echo-Doppler measures as primary or secondary efficacy or safety end-points. The present manuscript describes the methodology of the procedures (imaging acquisition and measurement reading) and provides the documentation of the work done so far to test the reproducibility of the different echo-Doppler modalities (standard and advanced). These procedures can be suggested for utilization also in non referall echocardiographic laboratories as an "inside" quality check, with the aim at optimizing clinical consistency of echo-Doppler data. PMID:21943283

  9. The reproducibility of single photon absorptiometry in a clinical setting

    International Nuclear Information System (INIS)

    Valkema, R.; Blokland, J.A.K.; Pauwels, E.K.J.; Papapoulos, S.E.; Bijvoet, O.L.M.

    1989-01-01

    The reproducibility of single photon absorptiometry (SPA) results for detection of changes in bone mineral content (BMC) was evaluated in a clinical setting. During a period of 18 months with 4 different sources, the calibration scans of an aluminium standard had a variation of less than 1% unless the activity of the 125 I source was low. The calibration procedure was performed weekly and this was sufficient to correct for drift of the system. The short term reproducibility in patients was assessed with 119 duplicate measurements made in direct succession. The best reproducibility (CV=1.35%) was found for fat corrected BMC results expressed in g/cm, obtained at the site proximal to the 8 mm space between the radius and ulna. Analysis of all SPA scans made during 1 year (487 scans) showed a failure of the automatic procedure to detect the space of 8 mm between the forearm bones in 19 scans (3.9%). A space adjacent to the ulnar styloid was taken as the site for the first scan in these examinations. This problem may be recognized and corrected relatively easy. A significant correlation was found between BMC at the lower arm and BMC of the lumbar spine assessed with dual photon absorptiometry. However, the error of estimation of proximal BMC (SEE=20%) and distal BMC (SEE=19.4%) made these measurements of little value to predict BMC at the lumbar spine in individuals. The short term reproducibility in patients combined with long term stability of the equipment in our clinical setting showed that SPA is a reliable technique to assess changes in bone mass at the lower arm of 4% between 2 measurements with a confidence level of 95%. (orig.)

  10. Diffusion Properties and 3D Architecture of Human Lower Leg Muscles Assessed with Ultra-High-Field-Strength Diffusion-Tensor MR Imaging and Tractography: Reproducibility and Sensitivity to Sex Difference and Intramuscular Variability.

    Science.gov (United States)

    Fouré, Alexandre; Ogier, Augustin C; Le Troter, Arnaud; Vilmen, Christophe; Feiweier, Thorsten; Guye, Maxime; Gondin, Julien; Besson, Pierre; Bendahan, David

    2018-05-01

    Purpose To demonstrate the reproducibility of the diffusion properties and three-dimensional structural organization measurements of the lower leg muscles by using diffusion-tensor imaging (DTI) assessed with ultra-high-field-strength (7.0-T) magnetic resonance (MR) imaging and tractography of skeletal muscle fibers. On the basis of robust statistical mapping analyses, this study also aimed at determining the sensitivity of the measurements to sex difference and intramuscular variability. Materials and Methods All examinations were performed with ethical review board approval; written informed consent was obtained from all volunteers. Reproducibility of diffusion tensor indexes assessment including eigenvalues, mean diffusivity, and fractional anisotropy (FA) as well as muscle volume and architecture (ie, fiber length and pennation angle) were characterized in lower leg muscles (n = 8). Intramuscular variability and sex differences were characterized in young healthy men and women (n = 10 in each group). Student t test, statistical parametric mapping, correlation coefficients (Spearman rho and Pearson product-moment) and coefficient of variation (CV) were used for statistical data analysis. Results High reproducibility of measurements (mean CV ± standard deviation, 4.6% ± 3.8) was determined in diffusion properties and architectural parameters. Significant sex differences were detected in FA (4.2% in women for the entire lower leg; P = .001) and muscle volume (21.7% in men for the entire lower leg; P = .008), whereas architecture parameters were almost identical across sex. Additional differences were found independently of sex in diffusion properties and architecture along several muscles of the lower leg. Conclusion The high-spatial-resolution DTI assessed with 7.0-T MR imaging allows a reproducible assessment of structural organization of superficial and deep muscles, giving indirect information on muscle function. © RSNA, 2018 Online supplemental material is

  11. Reproducibility of the Pleth Variability Index in premature infants

    NARCIS (Netherlands)

    Den Boogert, Wilhelmina J.; Van Elteren, Hugo A.; Goos, T.G.; Reiss, Irwin K.M.; De Jonge, Rogier C.J.; van Den Berg, Victor J.

    2017-01-01

    The aim was to assess the reproducibility of the Pleth Variability Index (PVI), developed for non-invasive monitoring of peripheral perfusion, in preterm neonates below 32 weeks of gestational age. Three PVI measurements were consecutively performed in stable, comfortable preterm neonates in the

  12. Test-Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease.

    Science.gov (United States)

    Palkovits, Stefan; Hirnschall, Nino; Georgiev, Stefan; Leisser, Christoph; Findl, Oliver

    2018-02-01

    To evaluate the test-retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training measurements, two additional microperimetry measurements were scheduled. Test-retest reproducibility was assessed for mean retinal sensitivity, pointwise sensitivity, and deep scotoma size using the coefficient of repeatability and Bland-Altman diagrams. In addition, in a subgroup of patients microperimetry was compared with conventional perimetry. Average differences in mean retinal sensitivity between the two study measurements were 0.26 ± 1.7 dB (median 0 dB; interquartile range [IQR] -1 to 1) for the healthy and 0.36 ± 2.5 dB (median 0 dB; IQR -1 to 2) for the macular patient group. Coefficients of repeatability for mean retinal sensitivity and pointwise retinal sensitivity were 1.2 and 3.3 dB for the healthy subjects and 1.6 and 5.0 dB for the macular disease patients, respectively. Absolute agreement in deep scotoma size between both study days was found in 79.9% of the test loci. The microperimeter MP3 shows an adequate test-retest reproducibility for mean retinal sensitivity, pointwise retinal sensitivity, and deep scotoma size in healthy subjects and patients suffering from macular disease. Furthermore, reproducibility of microperimetry is higher than conventional perimetry. Reproducibility is an important measure for each diagnostic device. Especially in a clinical setting high reproducibility set the basis to achieve reliable results using the specific device. Therefore, assessment of the reproducibility is of eminent importance to interpret the findings of future studies.

  13. A Reliable and Reproducible Model for Assessing the Effect of Different Concentrations of α-Solanine on Rat Bone Marrow Mesenchymal Stem Cells

    Directory of Open Access Journals (Sweden)

    Adriana Ordóñez-Vásquez

    2017-01-01

    Full Text Available Αlpha-solanine (α-solanine is a glycoalkaloid present in potato (Solanum tuberosum. It has been of particular interest because of its toxicity and potential teratogenic effects that include abnormalities of the central nervous system, such as exencephaly, encephalocele, and anophthalmia. Various types of cell culture have been used as experimental models to determine the effect of α-solanine on cell physiology. The morphological changes in the mesenchymal stem cell upon exposure to α-solanine have not been established. This study aimed to describe a reliable and reproducible model for assessing the structural changes induced by exposure of mouse bone marrow mesenchymal stem cells (MSCs to different concentrations of α-solanine for 24 h. The results demonstrate that nonlethal concentrations of α-solanine (2–6 μM changed the morphology of the cells, including an increase in the number of nucleoli, suggesting elevated protein synthesis, and the formation of spicules. In addition, treatment with α-solanine reduced the number of adherent cells and the formation of colonies in culture. Immunophenotypic characterization and staining of MSCs are proposed as a reproducible method that allows description of cells exposed to the glycoalkaloid, α-solanine.

  14. Quantitative and qualitative assessment of structural magnetic resonance imaging data in a two-center study

    International Nuclear Information System (INIS)

    Chalavi, Sima; Simmons, Andrew; Dijkstra, Hildebrand; Barker, Gareth J; Reinders, AAT Simone

    2012-01-01

    Multi-center magnetic resonance imaging (MRI) studies present an opportunity to advance research by pooling data. However, brain measurements derived from MR-images are susceptible to differences in MR-sequence parameters. It is therefore necessary to determine whether there is an interaction between the sequence parameters and the effect of interest, and to minimise any such interaction by careful choice of acquisition parameters. As an exemplar of the issues involved in multi-center studies, we present data from a study in which we aimed to optimize a set of volumetric MRI-protocols to define a protocol giving data that are consistent and reproducible across two centers and over time. Optimization was achieved based on data quality and quantitative measures, in our case using FreeSurfer and Voxel Based Morphometry approaches. Our approach consisted of a series of five comparisons. Firstly, a single-center dataset was collected, using a range of candidate pulse-sequences and parameters chosen on the basis of previous literature. Based on initial results, a number of minor changes were implemented to optimize the pulse-sequences, and a second single-center dataset was collected. FreeSurfer data quality measures were compared between datasets in order to determine the best performing sequence(s), which were taken forward to the next stage of testing. We subsequently acquired short-term and long-term two-center reproducibility data, and quantitative measures were again assessed to determine the protocol with the highest reproducibility across centers. Effects of a scanner software and hardware upgrade on the reproducibility of the protocols at one of the centers were also evaluated. Assessing the quality measures from the first two datasets allowed us to define artefact-free protocols, all with high image quality as assessed by FreeSurfer. Comparing the quantitative test and retest measures, we found high within-center reproducibility for all protocols, but lower

  15. The Reproducibility of Nuclear Morphometric Measurements in Invasive Breast Carcinoma

    Directory of Open Access Journals (Sweden)

    Pauliina Kronqvist

    1997-01-01

    Full Text Available The intraobserver and interobserver reproducibility of computerized nuclear morphometry was determined in repeated measurements of 212 samples of invasive breast cancer. The influence of biological variation and the selection of the measurement area was also tested. Morphometrically determined mean nuclear profile area (Pearson’s r 0.89, grading efficiency (GE 0.95 and standard deviation (SD of nuclear profile area (Pearson’s r 0.84, GE 0.89 showed high reproducibility. In this respect, nuclear morphometry equals with other established methods of quantitative pathology and exceeds the results of subjective grading of nuclear atypia in invasive breast cancer. A training period of eight days was sufficient to produce clear improvement in consistency of nuclear morphometry results. By estimating the sources of variation it could be shown that the variation associated with the measurement procedure itself is small. Instead, sample associated variation is responsible for the majority of variation in the measurements (82.9% in mean nuclear profile area and 65.9% in SD of nuclear profile area. This study points out that when standardized methods are applied computerized morphometry is a reproducible and reliable method of assessing nuclear atypia in invasive breast cancer. For further improvement special emphasize should be put on sampling rules of selecting the microscope fields and measurement areas.

  16. Reproducibility of Quantitative Structural and Physiological MRI Measurements

    Science.gov (United States)

    2017-08-09

    project.org/) and SPSS (IBM Corp., Armonk, NY) for data analysis. Mean and confidence inter- vals for each measure are found in Tables 1–7. To assess...visits, and was calculated using a two- way mixed model in SPSS MCV and MRD values closer to 0 are considered to be the most reproducible, and ICC

  17. Dark blood versus bright blood T2* acquisition in cardiovascular magnetic resonance (CMR) for thalassaemia major (TM) patients: Evaluation of feasibility, reproducibility and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Liguori, Carlo, E-mail: c.liguori@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Di Giampietro, Ilenia; Pitocco, Francesca; De Vivo, Aldo Eros [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Schena, Emiliano [Unit of Measurements and Biomedical Instrumentation, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Mortato, Luca [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Pirro, Federica [Department of Biomaging and Radiological Sciences, Catholic University of Sacred Herart, Largo A. Gemelli 1, 00135 Rome (Italy); Cianciulli, Paolo [Thalassemia Unit, Ospedale Sant Eugenio, Piazzale dell’Umanesimo 10, 00143 Rome (Italy); Zobel, Bruno Beomonte [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy)

    2014-01-15

    Objectives: To compare the effectiveness of dark blood (DB) versus bright blood (BB) sequences. To assess the intra and inter-observer variability and inter-study reproducibility between BB versus DB. To evaluate image quality level in the two sequences. Methods: In a setting of 138 patients we performed CMR using cardiac gated Gradient-multiecho single breath-hold BB and DB sequences in the middle ventricular septum. Each acquisition was repeated during the same exam. Truncation method was used to account for background noise. Image quality (IQ) was assessed using a 5 point grading scale and image analysis was conducted by 2 experienced observers. Results: Compared with the conventional BB acquisition, the coefficient of correlation and significance of the DB technique was superior for intra-observer reproducibility (p < 0.001), inter-observer reproducibility (p < 0.001) and inter-study reproducibility (p < 0.001). The variability is also lower for DB sequences for T2* values <14 ms. Assessment of artifacts showed a superior score for DB versus BB scans (4 versus 3, p < 0.001). Conclusions: Improvement in terms of inter observer and inter study variability using DB sequences was obtained. The greatest disparity between them was seen in inter-study reproducibility and higher IQ in DB was seen. Study demonstrates better performance of DB imaging compared to BB in presence of comparable effectiveness.

  18. The axiom about the market (cadastral cost of the reproducible factors of a single propert

    Directory of Open Access Journals (Sweden)

    A. D. Vlasov

    2017-01-01

    Full Text Available The purpose of the study. To prove the methodological error of the calculation of the market (cadastral value of capital construction objects, as a result of a violation of the Federal law of the Russian Federation of 29.07.1998 No. 135-FZ “On valuation activities in the Russian Federation”, article 3, in determining the market value of the property. To show that the theory and practice of measuring the value of real estate is necessary to delimit the elements of the market value formation of reproducible and not reproducible factors single property. Materials and methods. The objectives of the article are: the rules of law in assessment activities; the results of the cadastral valuation of real estate in settlements of Russia; comparative analysis of the factors determining the market (cadastral value of real estate. Results. Formulated the axiom about the market (cadastral cost of the reproducible factors of a single property. It is shown that in the theory and practice of measurement in market (cadastral value of real estate of Russia violated article 3 of the law 135-FZ of 29.07.1998. As a consequence, the market (cadastral cost of the capital construction objects 2-5 times overestimated, and the market (cadastral value of land in the 2-15 times underestimated. This is the basis of corruption, challenging the results of cadastral assessment of problems of formation of budgets of all levels, reduction in the rate of economic development of Russia. According to our results of the cadastral assessment of land plots of various categories of land in the regions of Russia there is a technology of determining the economic norms of rational use of real estate. Conclusion. Regardless of technology assessment of the property market value of reproducible improvements of the land may not exceed their replacement cost. 

  19. Reproducibility of MR-based Attenuation Maps in PET/MRI and the Impact on PET Quantification in Lung Cancer

    DEFF Research Database (Denmark)

    Olin, Anders; Ladefoged, Claes N; Langer, Natasha H

    2018-01-01

    AIM: Quantitative positron emission tomography/magnetic resonance imaging (PET/MRI) is dependent upon reliable and reproducible MR-based attenuation correction (MR-AC). In this study we evaluated the quality of current vendor-provided thoracic MR-AC maps, and further investigated...... affecting the reproducibility of PET/MRI. This, in combination with other well-known sources of error associated with PET/MRI examinations, leads to inconsistent SUV measurements in serial studies and follow-up scenarios, which may affect the reliability of therapy response assessment. A thorough visual...

  20. Reproducibility in a multiprocessor system

    Science.gov (United States)

    Bellofatto, Ralph A; Chen, Dong; Coteus, Paul W; Eisley, Noel A; Gara, Alan; Gooding, Thomas M; Haring, Rudolf A; Heidelberger, Philip; Kopcsay, Gerard V; Liebsch, Thomas A; Ohmacht, Martin; Reed, Don D; Senger, Robert M; Steinmacher-Burow, Burkhard; Sugawara, Yutaka

    2013-11-26

    Fixing a problem is usually greatly aided if the problem is reproducible. To ensure reproducibility of a multiprocessor system, the following aspects are proposed; a deterministic system start state, a single system clock, phase alignment of clocks in the system, system-wide synchronization events, reproducible execution of system components, deterministic chip interfaces, zero-impact communication with the system, precise stop of the system and a scan of the system state.

  1. Validity and reproducibility of a food frequency questionnaire focused on the Mediterranean diet for the Quebec population.

    Science.gov (United States)

    Cantin, J; Latour, E; Ferland-Verry, R; Morales Salgado, S; Lambert, J; Faraj, M; Nigam, A

    2016-02-01

    Validated dietary assessment methods specific to population and food habits are needed to conduct randomized clinical trials evaluating the efficacy of the Mediterranean diet in primary and secondary prevention of cardiovascular disease. Therefore, the aim of our study was to assess the reproducibility and the relative validity of a French language semi-quantitative food frequency questionnaire (FFQ) focused on the Mediterranean diet within the population of Quebec. Fifty-three participants aged 19-86 years with and without coronary heart disease were recruited, and randomized in 3 groups in a crossover design where the sequence of administration of two FFQs and a dietary record (DR) differed in each group. The FFQ includes 157 food items and was designed to measure food intake over one month. It was administered twice 3-5 weeks apart to assess reproducibility and was compared to a 12-day DR to assess validity. For reproducibility (n = 47), intraclass correlation coefficients (ICCs) for energy and 33 nutrients ranged from 0.38 to 0.91 (mean 0.63). For validity, the Pearson's correlation coefficients between the DR and the FFQ pre-DR ranged from 0.26 to 0.84 (mean 0.55) and ICCs ranged from 0.25 to 0.84 (mean 0.54). As for the DR and the FFQ post-DR, the Pearson's correlation coefficients ranged from 0.36 to 0.83 (mean 0.55) and the ICCs ranged from 0.36 to 0.83 (mean 0.53). This FFQ demonstrates good reproducibility and validity for most key nutrients of the Mediterranean diet for the Quebec population. Copyright © 2015 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  2. Reproducibility and relative validity of a semi-quantitative food-frequency questionnaire in an adult population of Rosario, Argentina

    OpenAIRE

    María Elisa Zapata; Romina Buffarini; Nadia Lingiardi; Ana Luiza Gonçalves-Soares

    2016-01-01

    Introduction: Dietary assessment of nutrients and food groups by food frequency questionnaire needs to be validated in each population. The objective of this cross-sectional study was to evaluate the reproducibility and relative validity of a semi-quantitative food frequency questionnaire among adults of Rosario, Argentina.Material and Methods: Two food frequency questionnaires and four 24-hour dietary recalls were applied in a sample of 88 adults. Reproducibility of food frequency questionna...

  3. In utero diffusion tensor imaging of the fetal brain: A reproducibility study.

    Science.gov (United States)

    Jakab, András; Tuura, Ruth; Kellenberger, Christian; Scheer, Ianina

    2017-01-01

    Our purpose was to evaluate the within-subject reproducibility of in utero diffusion tensor imaging (DTI) metrics and the visibility of major white matter structures. Images for 30 fetuses (20-33. postmenstrual weeks, normal neurodevelopment: 6 cases, cerebral pathology: 24 cases) were acquired on 1.5 T or 3.0 T MRI. DTI with 15 diffusion-weighting directions was repeated three times for each case, TR/TE: 2200/63 ms, voxel size: 1 ∗ 1 mm, slice thickness: 3-5 mm, b-factor: 700 s/mm 2 . Reproducibility was evaluated from structure detectability, variability of DTI measures using the coefficient of variation (CV), image correlation and structural similarity across repeated scans for six selected structures. The effect of age, scanner type, presence of pathology was determined using Wilcoxon rank sum test. White matter structures were detectable in the following percentage of fetuses in at least two of the three repeated scans: corpus callosum genu 76%, splenium 64%, internal capsule, posterior limb 60%, brainstem fibers 40% and temporooccipital association pathways 60%. The mean CV of DTI metrics ranged between 3% and 14.6% and we measured higher reproducibility in fetuses with normal brain development. Head motion was negatively correlated with reproducibility, this effect was partially ameliorated by motion-correction algorithm using image registration. Structures on 3.0 T had higher variability both with- and without motion correction. Fetal DTI is reproducible for projection and commissural bundles during mid-gestation, however, in 16-30% of the cases, data were corrupted by artifacts, resulting in impaired detection of white matter structures. To achieve robust results for the quantitative analysis of diffusivity and anisotropy values, fetal-specific image processing is recommended and repeated DTI is needed to ensure the detectability of fiber pathways.

  4. Assay reproducibility in clinical studies of plasma miRNA.

    Directory of Open Access Journals (Sweden)

    Jonathan Rice

    Full Text Available There are increasing reports of plasma miRNAs as biomarkers of human disease but few standards in methodologic reporting, leading to inconsistent data. We systematically reviewed plasma miRNA studies published between July 2013-June 2014 to assess methodology. Six parameters were investigated: time to plasma extraction, methods of RNA extraction, type of miRNA, quantification, cycle threshold (Ct setting, and methods of statistical analysis. We compared these data with a proposed standard methodologic technique. Beginning with initial screening for 380 miRNAs using microfluidic array technology and validation in an additional cohort of patients, we compared 11 miRNAs that exhibited differential expression between 16 patients with benign colorectal neoplasms (advanced adenomas and 16 patients without any neoplasm (controls. Plasma was isolated immediately, 12, 24, 48, or 72 h following phlebotomy. miRNA was extracted using two different techniques (Trizol LS with pre-amplification or modified miRNeasy. We performed Taqman-based RT-PCR assays for the 11 miRNAs with subsequent analyses using a variable Ct setting or a fixed Ct set at 0.01, 0.03, 0.05, or 0.5. Assays were performed in duplicate by two different operators. RNU6 was the internal reference. Systematic review yielded 74 manuscripts meeting inclusion criteria. One manuscript (1.4% documented all 6 methodological parameters, while < 5% of studies listed Ct setting. In our proposed standard technique, plasma extraction ≤12 h provided consistent ΔCt. miRNeasy extraction yielded higher miRNA concentrations and fewer non-expressed miRNAs compared to Trizol LS (1/704 miRNAs [0.14%] vs 109/704 miRNAs [15%], not expressed, respectively. A fixed Ct bar setting of 0.03 yielded the most reproducible data, provided that <10% miRNA were non-expressed. There was no significant intra-operator variability. There was significant inter-operator variation using Trizol LS extraction, while this was

  5. The intersubject and intrasubject reproducibility of FMRI activation during three encoding tasks: implications for clinical applications

    International Nuclear Information System (INIS)

    Harrington, Greg S.; Tomaszewski Farias, Sarah; Buonocore, Michael H.; Yonelinas, Andrew P.

    2006-01-01

    The goal of the present study was to evaluate the inter- and intrasubject reproducibility of FMRI activation for three memory encoding tasks previously used in the context of presurgical functional mapping. The primary region of interest (ROI) was the medial temporal lobe (MTL). Comparative ROIs included the inferior frontal and fusiform gyri which are less affected by susceptibility-induced signal losses than the MTL regions. Eighteen subjects were scanned using three memory encoding paradigms: word-pair, pattern, and scene encoding. Nine subjects underwent repeat scanning. Intersubject reproducibility of FMRI activation was evaluated by examining the percent of subjects who showed activation within a given ROI and the range to which individual laterality indices (LIs) varied from the mean. Intrasubject test-retest reproducibility was evaluated by examining the LI test-retest correlation, the average difference between LIs from two separate imaging sessions, and concordance ratios of activation volumes (R volume and R overlap ). For scene encoding the reproducibility of activation volume and LIs within the MTL were as good as or better than the reproducibility within the fusiform and inferior frontal ROIs. For pattern encoding and word-pair encoding, the reproducibility of activation volume and LIs within the MTL tended to be worse compared to the fusiform and inferior frontal ROIs. The differences in FMRI reproducibility appeared more dependent on the task than the susceptibility effects. The results of this study suggest that FMRI-based assessment of the neural substrates of memory using a scene encoding task may be a useful clinical tool. (orig.)

  6. The intersubject and intrasubject reproducibility of FMRI activation during three encoding tasks: implications for clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Harrington, Greg S. [Virginia Commonwealth University, Department of Radiology, Richmond, VA (United States); Tomaszewski Farias, Sarah [University of California at Davis, Department of Neurology, Sacramento (United States); Buonocore, Michael H. [University of California at Davis, Department of Radiology, Sacramento (United States); Yonelinas, Andrew P. [University of California at Davis, Department of Psychology, Davis (United States)

    2006-07-15

    The goal of the present study was to evaluate the inter- and intrasubject reproducibility of FMRI activation for three memory encoding tasks previously used in the context of presurgical functional mapping. The primary region of interest (ROI) was the medial temporal lobe (MTL). Comparative ROIs included the inferior frontal and fusiform gyri which are less affected by susceptibility-induced signal losses than the MTL regions. Eighteen subjects were scanned using three memory encoding paradigms: word-pair, pattern, and scene encoding. Nine subjects underwent repeat scanning. Intersubject reproducibility of FMRI activation was evaluated by examining the percent of subjects who showed activation within a given ROI and the range to which individual laterality indices (LIs) varied from the mean. Intrasubject test-retest reproducibility was evaluated by examining the LI test-retest correlation, the average difference between LIs from two separate imaging sessions, and concordance ratios of activation volumes (R{sub volume} and R{sub overlap}). For scene encoding the reproducibility of activation volume and LIs within the MTL were as good as or better than the reproducibility within the fusiform and inferior frontal ROIs. For pattern encoding and word-pair encoding, the reproducibility of activation volume and LIs within the MTL tended to be worse compared to the fusiform and inferior frontal ROIs. The differences in FMRI reproducibility appeared more dependent on the task than the susceptibility effects. The results of this study suggest that FMRI-based assessment of the neural substrates of memory using a scene encoding task may be a useful clinical tool. (orig.)

  7. Test–Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease

    Science.gov (United States)

    Palkovits, Stefan; Hirnschall, Nino; Georgiev, Stefan; Leisser, Christoph

    2018-01-01

    Purpose To evaluate the test–retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. Methods Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training measurements, two additional microperimetry measurements were scheduled. Test–retest reproducibility was assessed for mean retinal sensitivity, pointwise sensitivity, and deep scotoma size using the coefficient of repeatability and Bland-Altman diagrams. In addition, in a subgroup of patients microperimetry was compared with conventional perimetry. Results Average differences in mean retinal sensitivity between the two study measurements were 0.26 ± 1.7 dB (median 0 dB; interquartile range [IQR] −1 to 1) for the healthy and 0.36 ± 2.5 dB (median 0 dB; IQR −1 to 2) for the macular patient group. Coefficients of repeatability for mean retinal sensitivity and pointwise retinal sensitivity were 1.2 and 3.3 dB for the healthy subjects and 1.6 and 5.0 dB for the macular disease patients, respectively. Absolute agreement in deep scotoma size between both study days was found in 79.9% of the test loci. Conclusion The microperimeter MP3 shows an adequate test–retest reproducibility for mean retinal sensitivity, pointwise retinal sensitivity, and deep scotoma size in healthy subjects and patients suffering from macular disease. Furthermore, reproducibility of microperimetry is higher than conventional perimetry. Translational Relevance Reproducibility is an important measure for each diagnostic device. Especially in a clinical setting high reproducibility set the basis to achieve reliable results using the specific device. Therefore, assessment of the reproducibility is of eminent importance to interpret the findings of future studies. PMID:29430338

  8. Standing Together for Reproducibility in Large-Scale Computing: Report on reproducibility@XSEDE

    OpenAIRE

    James, Doug; Wilkins-Diehr, Nancy; Stodden, Victoria; Colbry, Dirk; Rosales, Carlos; Fahey, Mark; Shi, Justin; Silva, Rafael F.; Lee, Kyo; Roskies, Ralph; Loewe, Laurence; Lindsey, Susan; Kooper, Rob; Barba, Lorena; Bailey, David

    2014-01-01

    This is the final report on reproducibility@xsede, a one-day workshop held in conjunction with XSEDE14, the annual conference of the Extreme Science and Engineering Discovery Environment (XSEDE). The workshop's discussion-oriented agenda focused on reproducibility in large-scale computational research. Two important themes capture the spirit of the workshop submissions and discussions: (1) organizational stakeholders, especially supercomputer centers, are in a unique position to promote, enab...

  9. Theory of reproducing kernels and applications

    CERN Document Server

    Saitoh, Saburou

    2016-01-01

    This book provides a large extension of the general theory of reproducing kernels published by N. Aronszajn in 1950, with many concrete applications. In Chapter 1, many concrete reproducing kernels are first introduced with detailed information. Chapter 2 presents a general and global theory of reproducing kernels with basic applications in a self-contained way. Many fundamental operations among reproducing kernel Hilbert spaces are dealt with. Chapter 2 is the heart of this book. Chapter 3 is devoted to the Tikhonov regularization using the theory of reproducing kernels with applications to numerical and practical solutions of bounded linear operator equations. In Chapter 4, the numerical real inversion formulas of the Laplace transform are presented by applying the Tikhonov regularization, where the reproducing kernels play a key role in the results. Chapter 5 deals with ordinary differential equations; Chapter 6 includes many concrete results for various fundamental partial differential equations. In Chapt...

  10. Angiographic core laboratory reproducibility analyses: implications for planning clinical trials using coronary angiography and left ventriculography end-points.

    Science.gov (United States)

    Steigen, Terje K; Claudio, Cheryl; Abbott, David; Schulzer, Michael; Burton, Jeff; Tymchak, Wayne; Buller, Christopher E; John Mancini, G B

    2008-06-01

    To assess reproducibility of core laboratory performance and impact on sample size calculations. Little information exists about overall reproducibility of core laboratories in contradistinction to performance of individual technicians. Also, qualitative parameters are being adjudicated increasingly as either primary or secondary end-points. The comparative impact of using diverse indexes on sample sizes has not been previously reported. We compared initial and repeat assessments of five quantitative parameters [e.g., minimum lumen diameter (MLD), ejection fraction (EF), etc.] and six qualitative parameters [e.g., TIMI myocardial perfusion grade (TMPG) or thrombus grade (TTG), etc.], as performed by differing technicians and separated by a year or more. Sample sizes were calculated from these results. TMPG and TTG were also adjudicated by a second core laboratory. MLD and EF were the most reproducible, yielding the smallest sample size calculations, whereas percent diameter stenosis and centerline wall motion require substantially larger trials. Of the qualitative parameters, all except TIMI flow grade gave reproducibility characteristics yielding sample sizes of many 100's of patients. Reproducibility of TMPG and TTG was only moderately good both within and between core laboratories, underscoring an intrinsic difficulty in assessing these. Core laboratories can be shown to provide reproducibility performance that is comparable to performance commonly ascribed to individual technicians. The differences in reproducibility yield huge differences in sample size when comparing quantitative and qualitative parameters. TMPG and TTG are intrinsically difficult to assess and conclusions based on these parameters should arise only from very large trials.

  11. Effect of Initial Conditions on Reproducibility of Scientific Research

    Science.gov (United States)

    Djulbegovic, Benjamin; Hozo, Iztok

    2014-01-01

    Background: It is estimated that about half of currently published research cannot be reproduced. Many reasons have been offered as explanations for failure to reproduce scientific research findings- from fraud to the issues related to design, conduct, analysis, or publishing scientific research. We also postulate a sensitive dependency on initial conditions by which small changes can result in the large differences in the research findings when attempted to be reproduced at later times. Methods: We employed a simple logistic regression equation to model the effect of covariates on the initial study findings. We then fed the input from the logistic equation into a logistic map function to model stability of the results in repeated experiments over time. We illustrate the approach by modeling effects of different factors on the choice of correct treatment. Results: We found that reproducibility of the study findings depended both on the initial values of all independent variables and the rate of change in the baseline conditions, the latter being more important. When the changes in the baseline conditions vary by about 3.5 to about 4 in between experiments, no research findings could be reproduced. However, when the rate of change between the experiments is ≤2.5 the results become highly predictable between the experiments. Conclusions: Many results cannot be reproduced because of the changes in the initial conditions between the experiments. Better control of the baseline conditions in-between the experiments may help improve reproducibility of scientific findings. PMID:25132705

  12. Reliability and reproducibility analysis of the AOSpine thoracolumbar spine injury classification system by Chinese spinal surgeons.

    Science.gov (United States)

    Cheng, Jie; Liu, Peng; Sun, Dong; Qin, Tingzheng; Ma, Zikun; Liu, Jingpei

    2017-05-01

    The objective of this study was to analyze the interobserver reliability and intraobserver reproducibility of the new AOSpine thoracolumbar spine injury classification system in young Chinese orthopedic surgeons with different levels of experience in spinal trauma. Previous reports suggest that the new AOSpine thoracolumbar spine injury classification system demonstrates acceptable interobserver reliability and intraobserver reproducibility. However, there are few studies in Asia, especially in China. The AOSpine thoracolumbar spine injury classification system was applied to 109 patients with acute, traumatic thoracolumbar spinal injuries by two groups of spinal surgeons with different levels of clinical experience. The Kappa coefficient was used to determine interobserver reliability and intraobserver reproducibility. The overall Kappa coefficient for all cases was 0.362, which represents fair reliability. The Kappa statistic was 0.385 for A-type injuries and 0.292 for B-type injuries, which represents fair reliability, and 0.552 for C-type injuries, which represents moderate reliability. The Kappa coefficient for intraobserver reproducibility was 0.442 for A-type injuries, 0.485 for B-type injuries, and 0.412 for C-type injuries. These values represent moderate reproducibility for all injury types. The raters in Group A provided significantly better interobserver reliability than Group B (P < 0.05). There were no between-group differences in intraobserver reproducibility. This study suggests that the new AO spine injury classification system may be applied in day-to-day clinical practice in China following extensive training of healthcare providers. Further prospective studies in different healthcare providers and clinical settings are essential for validation of this classification system and to assess its utility.

  13. An empirical analysis of journal policy effectiveness for computational reproducibility.

    Science.gov (United States)

    Stodden, Victoria; Seiler, Jennifer; Ma, Zhaokun

    2018-03-13

    A key component of scientific communication is sufficient information for other researchers in the field to reproduce published findings. For computational and data-enabled research, this has often been interpreted to mean making available the raw data from which results were generated, the computer code that generated the findings, and any additional information needed such as workflows and input parameters. Many journals are revising author guidelines to include data and code availability. This work evaluates the effectiveness of journal policy that requires the data and code necessary for reproducibility be made available postpublication by the authors upon request. We assess the effectiveness of such a policy by ( i ) requesting data and code from authors and ( ii ) attempting replication of the published findings. We chose a random sample of 204 scientific papers published in the journal Science after the implementation of their policy in February 2011. We found that we were able to obtain artifacts from 44% of our sample and were able to reproduce the findings for 26%. We find this policy-author remission of data and code postpublication upon request-an improvement over no policy, but currently insufficient for reproducibility.

  14. Enhancing reproducibility in scientific computing: Metrics and registry for Singularity containers

    Science.gov (United States)

    Prybol, Cameron J.; Kurtzer, Gregory M.

    2017-01-01

    Here we present Singularity Hub, a framework to build and deploy Singularity containers for mobility of compute, and the singularity-python software with novel metrics for assessing reproducibility of such containers. Singularity containers make it possible for scientists and developers to package reproducible software, and Singularity Hub adds automation to this workflow by building, capturing metadata for, visualizing, and serving containers programmatically. Our novel metrics, based on custom filters of content hashes of container contents, allow for comparison of an entire container, including operating system, custom software, and metadata. First we will review Singularity Hub’s primary use cases and how the infrastructure has been designed to support modern, common workflows. Next, we conduct three analyses to demonstrate build consistency, reproducibility metric and performance and interpretability, and potential for discovery. This is the first effort to demonstrate a rigorous assessment of measurable similarity between containers and operating systems. We provide these capabilities within Singularity Hub, as well as the source software singularity-python that provides the underlying functionality. Singularity Hub is available at https://singularity-hub.org, and we are excited to provide it as an openly available platform for building, and deploying scientific containers. PMID:29186161

  15. Enhancing reproducibility in scientific computing: Metrics and registry for Singularity containers.

    Directory of Open Access Journals (Sweden)

    Vanessa V Sochat

    Full Text Available Here we present Singularity Hub, a framework to build and deploy Singularity containers for mobility of compute, and the singularity-python software with novel metrics for assessing reproducibility of such containers. Singularity containers make it possible for scientists and developers to package reproducible software, and Singularity Hub adds automation to this workflow by building, capturing metadata for, visualizing, and serving containers programmatically. Our novel metrics, based on custom filters of content hashes of container contents, allow for comparison of an entire container, including operating system, custom software, and metadata. First we will review Singularity Hub's primary use cases and how the infrastructure has been designed to support modern, common workflows. Next, we conduct three analyses to demonstrate build consistency, reproducibility metric and performance and interpretability, and potential for discovery. This is the first effort to demonstrate a rigorous assessment of measurable similarity between containers and operating systems. We provide these capabilities within Singularity Hub, as well as the source software singularity-python that provides the underlying functionality. Singularity Hub is available at https://singularity-hub.org, and we are excited to provide it as an openly available platform for building, and deploying scientific containers.

  16. Computed Tomography of the Human Pineal Gland for Study of the Sleep-Wake Rhythm: Reproducibility of a Semi-Quantitative Approach

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, S.A.; Platzek, I.; Kunz, D.; Mahlberg, R.; Wolf, K.J.; Heidenreich, J.O. [Charite - Universitaetsmedizin Berlin, Campus Benjamin Franklin, Berlin (Germany). Dept. of Radiology and Nuclear Medicine

    2006-10-15

    Purpose: To propose a semi-quantitative computed tomography (CT) protocol for determining uncalcified pineal tissue (UCPT), and to evaluate its reproducibility in modification of studies showing that the degree of calcification is a potential marker of deficient melatonin production and may prove an instability marker of circadian rhythm. Material and Methods: Twenty-two pineal gland autopsy specimens were scanned in a skull phantom with different slice thickness twice and the uncalcified tissue visually assessed using a four-point scale. The maximum gland density was measured and its inverse graded on a non-linear four-point scale. The sum of both scores was multiplied by the gland volume to yield the UCPT. The within-subject variance of UCPT was determined and compared between scans of different slice thickness. Results: The UCPT of the first measurement, in arbitrary units, was 39{+-}52.5 for 1 mm slice thickness, 44{+-}51.1 for 2 mm, 45{+-}34.8 for 4 mm, and 84{+-}58.0 for 8 mm. Significant differences of within-subject variance of UCPT were found between 1 and 4 mm, 1 and 8 mm, and 2 and 8 mm slice thicknesses ( P <0.05). Conclusion: A superior reproducibility of the semi-quantitative CT determination of UCPT was found using 1 and 2 mm slice thicknesses. These data support the use of thin slices of 1 and 2 mm. The benefit in reproducibility from thin slices has to be carefully weighted against their considerably higher radiation exposure.

  17. Reproducibility of graph metrics in fMRI networks

    Directory of Open Access Journals (Sweden)

    Qawi K Telesford

    2010-12-01

    Full Text Available The reliability of graph metrics calculated in network analysis is essential to the interpretation of complex network organization. These graph metrics are used to deduce the small-world properties in networks. In this study, we investigated the test-retest reliability of graph metrics from functional magnetic resonance imaging (fMRI data collected for two runs in 45 healthy older adults. Graph metrics were calculated on data for both runs and compared using intraclass correlation coefficient (ICC statistics and Bland-Altman (BA plots. ICC scores describe the level of absolute agreement between two measurements and provide a measure of reproducibility. For mean graph metrics, ICC scores were high for clustering coefficient (ICC=0.86, global efficiency (ICC=0.83, path length (ICC=0.79, and local efficiency (ICC=0.75; the ICC score for degree was found to be low (ICC=0.29. ICC scores were also used to generate reproducibility maps in brain space to test voxel-wise reproducibility for unsmoothed and smoothed data. Reproducibility was uniform across the brain for global efficiency and path length, but was only high in network hubs for clustering coefficient, local efficiency and degree. BA plots were used to test the measurement repeatability of all graph metrics. All graph metrics fell within the limits for repeatability. Together, these results suggest that with exception of degree, mean graph metrics are reproducible and suitable for clinical studies. Further exploration is warranted to better understand reproducibility across the brain on a voxel-wise basis.

  18. Language-Agnostic Reproducible Data Analysis Using Literate Programming.

    Science.gov (United States)

    Vassilev, Boris; Louhimo, Riku; Ikonen, Elina; Hautaniemi, Sampsa

    2016-01-01

    A modern biomedical research project can easily contain hundreds of analysis steps and lack of reproducibility of the analyses has been recognized as a severe issue. While thorough documentation enables reproducibility, the number of analysis programs used can be so large that in reality reproducibility cannot be easily achieved. Literate programming is an approach to present computer programs to human readers. The code is rearranged to follow the logic of the program, and to explain that logic in a natural language. The code executed by the computer is extracted from the literate source code. As such, literate programming is an ideal formalism for systematizing analysis steps in biomedical research. We have developed the reproducible computing tool Lir (literate, reproducible computing) that allows a tool-agnostic approach to biomedical data analysis. We demonstrate the utility of Lir by applying it to a case study. Our aim was to investigate the role of endosomal trafficking regulators to the progression of breast cancer. In this analysis, a variety of tools were combined to interpret the available data: a relational database, standard command-line tools, and a statistical computing environment. The analysis revealed that the lipid transport related genes LAPTM4B and NDRG1 are coamplified in breast cancer patients, and identified genes potentially cooperating with LAPTM4B in breast cancer progression. Our case study demonstrates that with Lir, an array of tools can be combined in the same data analysis to improve efficiency, reproducibility, and ease of understanding. Lir is an open-source software available at github.com/borisvassilev/lir.

  19. How well can DFT reproduce key interactions in Ziegler-Natta systems?

    KAUST Repository

    Correa, Andrea; Bahri-Laleh, Naeimeh; Cavallo, Luigi

    2013-01-01

    The performance of density functional theory in reproducing some of the main interactions occurring in MgCl2-supported Ziegler-Natta catalytic systems is assessed. Eight model systems, representatives of key interactions occurring in Ziegler

  20. A prospective study assessing agreement and reliability of a geriatric evaluation

    OpenAIRE

    Locatelli, Isabella; Monod, St?fanie; Cornuz, Jacques; B?la, Christophe J.; Senn, Nicolas

    2017-01-01

    Background The present study takes place within a geriatric program, aiming at improving the diagnosis and management of geriatric syndromes in primary care. Within this program it was of prime importance to be able to rely on a robust and reproducible geriatric consultation to use as a gold standard for evaluating a primary care brief assessment tool. The specific objective of the present study was thus assessing the agreement and reliability of a comprehensive geriatric consultation. Method...

  1. Intra- and interobserver reliability and intra-catheter reproducibility using frequency domain optical coherence tomography for the evaluation of morphometric stent parameters and qualitative assessment of stent strut coverage

    International Nuclear Information System (INIS)

    Antonsen, Lisbeth; Thayssen, Per; Junker, Anders; Veien, Karsten Tange; Hansen, Henrik Steen; Hansen, Knud Nørregaard; Hougaard, Mikkel; Jensen, Lisette Okkels

    2015-01-01

    Purpose: Frequency-domain optical coherence tomography (FD-OCT) is a high-resolution imaging tool (~ 10–15 μm), which enables near-histological in-vivo images of the coronary vessel wall. The use of the technique is increasing, both for research- and clinical purposes. This study sought to investigate the intra- and interobserver reliability, as well as the intra-catheter reproducibility of quantitative FD-OCT-assessment of morphometric stent parameters and qualitative FD-OCT-evaluation of strut coverage in 10 randomly selected 6-month follow-up Nobori® biolimus-eluting stents (N-BESs). Methods: Ten N-BESs (213 cross sectional areas (CSAs) and 1897 struts) imaged with OCT 6 months post-implantation were randomly selected and analyzed by 2 experienced analysts, and the same 10 N-BESs were analyzed by one of the analysts 3 months later. Further, 2 consecutive pullbacks randomly performed in another 10 N-BESs (219 CSAs and 1860 struts) were independently assessed by one of the analysts. Results: The intraobserver variability with regard to relative difference of mean luminal area and mean stent area at the CSA-level was very low: 0.1% ± 1.4% and 0.5% ± 3.2%. Interobserver variability also proved to be low: − 2.1% ± 3.3% and 2.1% ± 4.6%, and moreover, very restricted intra-catheter variation was observed: 0.02% ± 6.8% and − 0.18% ± 5.2%. The intraobserver-, interobserver- and intra-catheter reliability for the qualitative evaluation of strut coverage was found to be: kappa (κ) = 0.91 (95% confidence interval (CI): 0.88–0.93, p < 0.01), κ = 0.88 (95% CI: 0.85–0.91, p < 0.01), and κ = 0.73 (95% CI: 0.68–0.78, p < 0.01), respectively. Conclusions: FD-OCT is a reproducible and reliable imaging tool for quantitative evaluation of stented coronary segments, and for qualitative assessment of strut coverage. - Highlights: • Frequency-domain optical coherence tomography (FD-OCT) is increasingly adopted in the catherization laboratories. • This

  2. Intra- and interobserver reliability and intra-catheter reproducibility using frequency domain optical coherence tomography for the evaluation of morphometric stent parameters and qualitative assessment of stent strut coverage

    Energy Technology Data Exchange (ETDEWEB)

    Antonsen, Lisbeth, E-mail: Lisbeth.antonsen@rsyd.dk; Thayssen, Per; Junker, Anders; Veien, Karsten Tange; Hansen, Henrik Steen; Hansen, Knud Nørregaard; Hougaard, Mikkel; Jensen, Lisette Okkels

    2015-12-15

    Purpose: Frequency-domain optical coherence tomography (FD-OCT) is a high-resolution imaging tool (~ 10–15 μm), which enables near-histological in-vivo images of the coronary vessel wall. The use of the technique is increasing, both for research- and clinical purposes. This study sought to investigate the intra- and interobserver reliability, as well as the intra-catheter reproducibility of quantitative FD-OCT-assessment of morphometric stent parameters and qualitative FD-OCT-evaluation of strut coverage in 10 randomly selected 6-month follow-up Nobori® biolimus-eluting stents (N-BESs). Methods: Ten N-BESs (213 cross sectional areas (CSAs) and 1897 struts) imaged with OCT 6 months post-implantation were randomly selected and analyzed by 2 experienced analysts, and the same 10 N-BESs were analyzed by one of the analysts 3 months later. Further, 2 consecutive pullbacks randomly performed in another 10 N-BESs (219 CSAs and 1860 struts) were independently assessed by one of the analysts. Results: The intraobserver variability with regard to relative difference of mean luminal area and mean stent area at the CSA-level was very low: 0.1% ± 1.4% and 0.5% ± 3.2%. Interobserver variability also proved to be low: − 2.1% ± 3.3% and 2.1% ± 4.6%, and moreover, very restricted intra-catheter variation was observed: 0.02% ± 6.8% and − 0.18% ± 5.2%. The intraobserver-, interobserver- and intra-catheter reliability for the qualitative evaluation of strut coverage was found to be: kappa (κ) = 0.91 (95% confidence interval (CI): 0.88–0.93, p < 0.01), κ = 0.88 (95% CI: 0.85–0.91, p < 0.01), and κ = 0.73 (95% CI: 0.68–0.78, p < 0.01), respectively. Conclusions: FD-OCT is a reproducible and reliable imaging tool for quantitative evaluation of stented coronary segments, and for qualitative assessment of strut coverage. - Highlights: • Frequency-domain optical coherence tomography (FD-OCT) is increasingly adopted in the catherization laboratories. • This

  3. Assessment of reproducibility and stability of different breath-hold maneuvres by dynamic MRI: comparison between healthy adults and patients with pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Plathow, Christian [German Cancer Research Center Heidelberg, Department of Radiology, Heidelberg (Germany); Eberhard-Karls-University Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Ley, Sebastian; Zaporozhan, Julia; Puderbach, Michael; Eichinger, Monika; Zuna, Ivan; Kauczor, Hans-Ulrich [German Cancer Research Center Heidelberg, Department of Radiology, Heidelberg (Germany); Schoebinger, Max; Meinzer, Hans-Peter [German Cancer Research Center Heidelberg, Department of Medical and Biological Informatics, Heidelberg (Germany); Gruenig, Ekkehard [University of Heidelberg, Department of Internal Medicine III, Heidelberg (Germany)

    2006-01-01

    To assess the stability and reproducibility of different breath-hold levels in healthy volunteers and patients using dynamic MRI (dMRI). In ten healthy volunteers and ten patients with pulmonary hypertension (PH) and normal lung function craniocaudal intrathoracic distances (CCD) were measured during inspiratory and expiratory breath-hold (15 s) (in healthy volunteers additionally at a self-chosen mid-inspiratory breath-hold) using dMRI (trueFISP, three images/s). To evaluate stability and intraobserver reproducibility of the different breath-hold levels, CCDs, time-distance curves, confidence intervals (CIs), Mann-Witney U test and regression equations were calculated. In healthy volunteers there was a substantial decrease of the CCD during the inspiratory breath-hold in contrast to the expiratory breath-hold. The CI at inspiration was 2.84{+-}1.28 in the right and 2.1{+-}0.68 in the left hemithorax. At expiration the CI was 2.54{+-}1.18 and 2.8{+-}1.48. Patients were significantly less able to hold their breath at inspiration than controls (P<0.05). In patients CI was 4.53{+-}4.06 and 3.46{+-}2.21 at inspiration and 4.45{+-}4.23 and 4.76{+-}3.73 at expiration. Intraobserver variability showed no significant differences either in patients or in healthy subjects. Reproducibility was significantly lower at a self-chosen breath-hold level of the healthy volunteers. DMRI is able to differentiate stability and reproducibility of different breath-hold levels. Expiratory breath-hold proved to be more stable than inspiratory breath-hold in healthy volunteers and patients. (orig.)

  4. Reproducibility of quantitative planar thallium-201 scintigraphy: quantitative criteria for reversibility of myocardial perfusion defects

    International Nuclear Information System (INIS)

    Sigal, S.L.; Soufer, R.; Fetterman, R.C.; Mattera, J.A.; Wackers, F.J.

    1991-01-01

    Fifty-two paired stress/delayed planar 201 TI studies (27 exercise studies, 25 dipyridamole studies) were processed twice by seven technologists to assess inter- and intraobserver variability. The reproducibility was inversely related to the size of 201 Tl perfusion abnormalities. Intraobserver variability was not different between exercise and dipyridamole studies for lesions of similar size. Based upon intraobserver variability, objective quantitative criteria for reversibility of perfusion abnormalities were defined. These objective criteria were tested prospectively in a separate group of 35 201 Tl studies and compared with the subjective interpretation of quantitative circumferential profiles. Overall, exact agreement existed in 78% of images (kappa statistic k = 0.66). We conclude that quantification of planar 201 Tl scans is highly reproducible, with acceptable inter- and intraobserver variability. Objective criteria for lesion reversibility correlated well with analysis by experienced observers

  5. Reliability and reproducibility of disc-foveal angle measurements by non-mydriatic fundus photography.

    Science.gov (United States)

    Le Jeune, Caroline; Chebli, Fayçal; Leon, Lorette; Anthoine, Emmanuelle; Weber, Michel; Péchereau, Alain; Lebranchu, Pierre

    2018-01-01

    Abnormal torsion could be associated with cyclovertical strabismus, but torsion measurements are not reliable in children. To assess an objective fundus torsion evaluation in a paediatric population, we used Non-Mydriatic Fundus photography (NMFP) in healthy and cyclovertical strabismus patients to evaluate the disc-foveal angle over time and observers. We used a retrospective set of NMFP including 24 A or V-pattern strabismus and 27 age-matched normal children (mean age 6.4 and 6.7 years respectively), taken during 2 distinct follow-up consultations (separated by 251 and 479 days respectively). Each disc-foveal angle measurement (from which the ocular torsion can be assessed) was performed by 5 different observers, using graphical software and based on reproducible fundus anatomical marks. Statistical analysis was performed with a multivariate ANOVA using group, time and observers as factors, in addition to intraclass coefficient correlation (ICC) to assess measurement reproducibility. A significant difference of disc-foveal angle measures was observed between groups (p0,97). Abnormal amount of objective torsion could be associated with alphabet-pattern strabismus. Disc-foveal angle evaluation by NMFP in a children population appears as a non-invasive, reliable and reproducible method.

  6. Optimising diffusion weighted MRI for imaging metastatic and myeloma bone disease and assessing reproducibility

    International Nuclear Information System (INIS)

    Messiou, C.; Collins, D.J.; Morgan, V.A.; DeSouza, N.M.

    2011-01-01

    To establish normal bone marrow values of apparent diffusion coefficient (ADC) over an age range, compare them with metastatic and myelomatous involvement, to establish reproducibility and to optimise b values. The ADCs of bone marrow in 7 volunteers (mean age 29.7 years), 34 volunteers (mean age 63.3 years) and 43 patients with metastatic and myelomatous involvement (mean age 65.5 years) were measured. In 9 volunteers diffusion weighted MRI was repeated within 7 days. b values were derived to optimise contrast between normal and pathological marrow. The mean ADC of bone marrow in younger volunteers was significantly higher than that of older volunteers. The coefficient of reproducibility was 14.8%. The ADC mean of metastatic and myeloma bone disease was 1054+/-456 x 10 -6 mm 2 s -1 . An ADC threshold of 655 x 10 -6 mm 2 s -1 separated normal and abnormal marrow with a sensitivity and specificity of 90% and 93% respectively. Contrast between normal and abnormal marrow was optimal at b = 1389 smm -2 . The reproducibility of ADC measurements in bone is equivalent to published data for soft tissue with a high sensitivity and specificity for separating abnormal from age matched normal bone marrow. A b value of around 1,400 smm -2 is optimal for imaging bone marrow. (orig.)

  7. Optimising diffusion weighted MRI for imaging metastatic and myeloma bone disease and assessing reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Messiou, C. [Institute of Cancer Research and Royal Marsden, NHS Foundation Trust, Cancer Research UK Clinical Magnetic Resonance Research Group, Surrey (United Kingdom); Institute of Cancer Research and Royal Marsden, NHS Foundation Trust, MRI Department, Surrey (United Kingdom); Collins, D.J.; Morgan, V.A.; DeSouza, N.M. [Institute of Cancer Research and Royal Marsden, NHS Foundation Trust, Cancer Research UK Clinical Magnetic Resonance Research Group, Surrey (United Kingdom)

    2011-08-15

    To establish normal bone marrow values of apparent diffusion coefficient (ADC) over an age range, compare them with metastatic and myelomatous involvement, to establish reproducibility and to optimise b values. The ADCs of bone marrow in 7 volunteers (mean age 29.7 years), 34 volunteers (mean age 63.3 years) and 43 patients with metastatic and myelomatous involvement (mean age 65.5 years) were measured. In 9 volunteers diffusion weighted MRI was repeated within 7 days. b values were derived to optimise contrast between normal and pathological marrow. The mean ADC of bone marrow in younger volunteers was significantly higher than that of older volunteers. The coefficient of reproducibility was 14.8%. The ADC mean of metastatic and myeloma bone disease was 1054+/-456 x 10{sup -6} mm{sup 2}s{sup -1}. An ADC threshold of 655 x 10{sup -6} mm{sup 2}s{sup -1} separated normal and abnormal marrow with a sensitivity and specificity of 90% and 93% respectively. Contrast between normal and abnormal marrow was optimal at b = 1389 smm{sup -2}. The reproducibility of ADC measurements in bone is equivalent to published data for soft tissue with a high sensitivity and specificity for separating abnormal from age matched normal bone marrow. A b value of around 1,400 smm{sup -2} is optimal for imaging bone marrow. (orig.)

  8. Measurement and Reproducibility of Preserved Ellipsoid Zone Area and Preserved Retinal Pigment Epithelium Area in Eyes With Choroideremia

    DEFF Research Database (Denmark)

    Hariri, Amir H; Velaga, Swetha B; Girach, Aniz

    2017-01-01

    PURPOSE: To identify valid and reproducible methods for quantifying anatomic outcome measures for eyes with choroideremia (CHM) in clinical trials. DESIGN: Reliability analysis study. METHODS: In this multicenter study, patients with confirmed genetic diagnosis of CHM were enrolled. All cases...... of both FAF and OCT images were compared to assess the reproducibility of the grading methods. RESULTS: A total of 148 eyes from 75 cases were included. In 21% of eyes PAF and in 43% of eyes preserved EZ had extended beyond the image capture area. After exclusion of these eyes and low-quality images, 114...

  9. The MIMIC Code Repository: enabling reproducibility in critical care research.

    Science.gov (United States)

    Johnson, Alistair Ew; Stone, David J; Celi, Leo A; Pollard, Tom J

    2018-01-01

    Lack of reproducibility in medical studies is a barrier to the generation of a robust knowledge base to support clinical decision-making. In this paper we outline the Medical Information Mart for Intensive Care (MIMIC) Code Repository, a centralized code base for generating reproducible studies on an openly available critical care dataset. Code is provided to load the data into a relational structure, create extractions of the data, and reproduce entire analysis plans including research studies. Concepts extracted include severity of illness scores, comorbid status, administrative definitions of sepsis, physiologic criteria for sepsis, organ failure scores, treatment administration, and more. Executable documents are used for tutorials and reproduce published studies end-to-end, providing a template for future researchers to replicate. The repository's issue tracker enables community discussion about the data and concepts, allowing users to collaboratively improve the resource. The centralized repository provides a platform for users of the data to interact directly with the data generators, facilitating greater understanding of the data. It also provides a location for the community to collaborate on necessary concepts for research progress and share them with a larger audience. Consistent application of the same code for underlying concepts is a key step in ensuring that research studies on the MIMIC database are comparable and reproducible. By providing open source code alongside the freely accessible MIMIC-III database, we enable end-to-end reproducible analysis of electronic health records. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  10. The Reproducibility and Comparative Validity of a Non-Nutritive Sweetener Food Frequency Questionnaire

    Directory of Open Access Journals (Sweden)

    Emily A. Myers

    2018-03-01

    Full Text Available In order to better assess non-nutritive sweetener (NNS consumption, measurement tools with greater utility are needed. The objective of this investigation is to determine the reproducibility and validity of a newly developed NNS food frequency questionnaire (NNS-FFQ that measures five types of NNS (saccharin, aspartame, acesulfame potassium, sucralose and erythritol. Adult participants (n = 123, 56% female, 75% Caucasian, mean age = 36.8 ± 16.6 completed the NNS-FFQ twice and had 24-h dietary recalls three times over a two-week study period. Reproducibility between two administrations of the NNS-FFQ was assessed via Bland–Altman plots, Spearman’s correlations (rs and paired samples t-tests. Bland–Altman plots, Cohen’s κ, Spearman’s correlations (rs, and paired samples t-tests compared NNS intake between the two methods for validity. For reproducibility analyses, Bland–Altman analyses revealed agreement levels above the 95% acceptance level for total NNS (99.2%, erythritol (99.2%, and aspartame (96.7%. Agreement levels for acesulfame potassium (94.3%, saccharin (94.3%, and sucralose (94.3% were slightly below the acceptable level. For validity analyses, Bland–Altman analyses revealed agreement levels above the 95% acceptance level for total NNS (95.1%, sucralose (95.9%, saccharin (95.9%, and erythritol (95.1%. Agreement levels for aspartame (94.3% and acesulfame potassium (92.7% were slightly below the acceptable level. Although less than desirable agreement was found between the methods for aspartame and acesulfame potassium, some variance was expected due to the habitual nature of the NNS-FFQ as compared to the recent intake reported by recalls. Within the context of this constraint, the NNS-FFQ demonstrates acceptable reproducibility and validity. The NNS-FFQ is a brief questionnaire that could be administered among diverse participants at the individual and population levels to measure habitual NNS intake.

  11. Validity and Reproducibility of a Food Frequency Questionnaire for Dietary Factors Related to Colorectal Cancer

    Directory of Open Access Journals (Sweden)

    Daniel Nigusse Tollosa

    2017-11-01

    Full Text Available Dietary factors play a major role in the development of colorectal cancer. This study evaluated the reproducibility and validity of a 109-food item Food Frequency Questionnaire (FFQ to measure the consumption of foods and nutrients related to the development of colorectal cancer in a population aged ≥50 years in Flanders, Belgium. A semi-quantitative FFQ was administered two times in a period of two weeks to evaluate reproducibility (FFQ1 and FFQ2. The validity of the FFQ was assessed by comparing FFQ1 against the 3-day diary method (3 DD. A total of 162 respondents (mean age 57.5 years provided data for the FFQ, of whom 156 also participated in the validity assessment. Mean differences in the intake of foods and nutrients between FFQ1 and FFQ2 were, overall, small and statistically insignificant. However, a higher estimation was observed by FFQ1 as compared to the 3-DD method for the majority of food groups and nutrient intake in the validity assessment. A systematic mean difference (g/day was observed for eight food groups in the Bland–Altman agreement test; the largest was for fruit intake. Regarding the nutrients, a systematic mean difference was observed in calcium, fat, and vitamin D intake. Overall, the reproducibility of the FFQ was good, and its validity could be satisfactory for estimating absolute food and nutrient intakes and ranking individuals according to high and low intake categories.

  12. Validity and Reproducibility of a Food Frequency Questionnaire for Dietary Factors Related to Colorectal Cancer.

    Science.gov (United States)

    Tollosa, Daniel Nigusse; Van Camp, John; Huybrechts, Inge; Huybregts, Lieven; Van Loco, Joris; De Smet, Stefaan; Sterck, Ellen; Rabâi, Céline; Van Hecke, Thomas; Vanhaecke, Lynn; Vossen, Els; Peeters, Marc; Lachat, Carl

    2017-11-17

    Dietary factors play a major role in the development of colorectal cancer. This study evaluated the reproducibility and validity of a 109-food item Food Frequency Questionnaire (FFQ) to measure the consumption of foods and nutrients related to the development of colorectal cancer in a population aged ≥50 years in Flanders, Belgium. A semi-quantitative FFQ was administered two times in a period of two weeks to evaluate reproducibility (FFQ1 and FFQ2). The validity of the FFQ was assessed by comparing FFQ1 against the 3-day diary method (3 DD). A total of 162 respondents (mean age 57.5 years) provided data for the FFQ, of whom 156 also participated in the validity assessment. Mean differences in the intake of foods and nutrients between FFQ1 and FFQ2 were, overall, small and statistically insignificant. However, a higher estimation was observed by FFQ1 as compared to the 3-DD method for the majority of food groups and nutrient intake in the validity assessment. A systematic mean difference (g/day) was observed for eight food groups in the Bland-Altman agreement test; the largest was for fruit intake. Regarding the nutrients, a systematic mean difference was observed in calcium, fat, and vitamin D intake. Overall, the reproducibility of the FFQ was good, and its validity could be satisfactory for estimating absolute food and nutrient intakes and ranking individuals according to high and low intake categories.

  13. Reproducibility of wrist home blood pressure measurement with position sensor and automatic data storage

    Science.gov (United States)

    Uen, Sakir; Fimmers, Rolf; Brieger, Miriam; Nickenig, Georg; Mengden, Thomas

    2009-01-01

    Background Wrist blood pressure (BP) devices have physiological limits with regards to accuracy, therefore they were not preferred for home BP monitoring. However some wrist devices have been successfully validated using etablished validation protocols. Therefore this study assessed the reproducibility of wrist home BP measurement with position sensor and automatic data storage. Methods To compare the reproducibility of three different(BP) measurement methods: 1) office BP, 2) home BP (Omron wrist device HEM- 637 IT with position sensor), 3) 24-hour ambulatory BP(24-h ABPM) (ABPM-04, Meditech, Hun)conventional sphygmomanometric office BP was measured on study days 1 and 7, 24-h ABPM on study days 7 and 14 and home BP between study days 1 and 7 and between study days 8 and 14 in 69 hypertensive and 28 normotensive subjects. The correlation coeffcient of each BP measurement method with echocardiographic left ventricular mass index was analyzed. The schedule of home readings was performed according to recently published European Society of Hypertension (ESH)- guidelines. Results The reproducibility of home BP measurement analyzed by the standard deviation as well as the squared differeces of mean individual differences between the respective BP measurements was significantly higher than the reproducibility of office BP (p ABPM (p ABPM was not significantly different (p = 0.80 systolic BP, p = 0.1 diastolic BP). The correlation coefficient of 24-h ABMP (r = 0.52) with left ventricular mass index was significantly higher than with office BP (r = 0.31). The difference between 24-h ABPM and home BP (r = 0.46) was not significant. Conclusion The short-term reproducibility of home BP measurement with the Omron HEM-637 IT wrist device was superior to the reproducibility of office BP and 24- h ABPM measurement. Furthermore, home BP with the wrist device showed similar correlations to targed organ damage as recently reported for upper arm devices. Although wrist devices have

  14. Comparative validity and reproducibility study of various landmark-oriented reference planes in 3-dimensional computed tomographic analysis for patients receiving orthognathic surgery.

    Science.gov (United States)

    Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou

    2015-01-01

    Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. The 5 horizontal reference planes were reliable and

  15. Assessment of reproducibility and stability of different breath-hold maneuvres by dynamic MRI: comparison between healthy adults and patients with pulmonary hypertension

    International Nuclear Information System (INIS)

    Plathow, Christian; Ley, Sebastian; Zaporozhan, Julia; Puderbach, Michael; Eichinger, Monika; Zuna, Ivan; Kauczor, Hans-Ulrich; Schoebinger, Max; Meinzer, Hans-Peter; Gruenig, Ekkehard

    2006-01-01

    To assess the stability and reproducibility of different breath-hold levels in healthy volunteers and patients using dynamic MRI (dMRI). In ten healthy volunteers and ten patients with pulmonary hypertension (PH) and normal lung function craniocaudal intrathoracic distances (CCD) were measured during inspiratory and expiratory breath-hold (15 s) (in healthy volunteers additionally at a self-chosen mid-inspiratory breath-hold) using dMRI (trueFISP, three images/s). To evaluate stability and intraobserver reproducibility of the different breath-hold levels, CCDs, time-distance curves, confidence intervals (CIs), Mann-Witney U test and regression equations were calculated. In healthy volunteers there was a substantial decrease of the CCD during the inspiratory breath-hold in contrast to the expiratory breath-hold. The CI at inspiration was 2.84±1.28 in the right and 2.1±0.68 in the left hemithorax. At expiration the CI was 2.54±1.18 and 2.8±1.48. Patients were significantly less able to hold their breath at inspiration than controls (P<0.05). In patients CI was 4.53±4.06 and 3.46±2.21 at inspiration and 4.45±4.23 and 4.76±3.73 at expiration. Intraobserver variability showed no significant differences either in patients or in healthy subjects. Reproducibility was significantly lower at a self-chosen breath-hold level of the healthy volunteers. DMRI is able to differentiate stability and reproducibility of different breath-hold levels. Expiratory breath-hold proved to be more stable than inspiratory breath-hold in healthy volunteers and patients. (orig.)

  16. Dysplastic naevus: histological criteria and their inter-observer reproducibility.

    Science.gov (United States)

    Hastrup, N; Clemmensen, O J; Spaun, E; Søndergaard, K

    1994-06-01

    Forty melanocytic lesions were examined in a pilot study, which was followed by a final series of 100 consecutive melanocytic lesions, in order to evaluate the inter-observer reproducibility of the histological criteria proposed for the dysplastic naevus. The specimens were examined in a blind fashion by four observers. Analysis by kappa statistics showed poor reproducibility of nuclear features, while reproducibility of architectural features was acceptable, improving in the final series. Consequently, we cannot apply the combined criteria of cytological and architectural features with any confidence in the diagnosis of dysplastic naevus, and, until further studies have documented that architectural criteria alone will suffice in the diagnosis of dysplastic naevus, we, as pathologists, shall avoid this term.

  17. Intra-observer reproducibility and diagnostic performance of breast shear-wave elastography in Asian women.

    Science.gov (United States)

    Park, Hye Young; Han, Kyung Hwa; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Min Jung; Kim, Eun-Kyung

    2014-06-01

    Our aim was to evaluate intra-observer reproducibility of shear-wave elastography (SWE) in Asian women. Sixty-four breast masses (24 malignant, 40 benign) were examined with SWE in 53 consecutive Asian women (mean age, 44.9 y old). Two SWE images were obtained for each of the lesions. The intra-observer reproducibility was assessed by intra-class correlation coefficients (ICC). We also evaluated various clinicoradiologic factors that can influence reproducibility in SWE. The ICC of intra-observer reproducibility was 0.789. In clinicoradiologic factor evaluation, masses surrounded by mixed fatty and glandular tissue (ICC: 0.619) showed lower intra-observer reproducibility compared with lesions that were surrounded by glandular tissue alone (ICC: 0.937; p breast SWE was excellent in Asian women. However, it may decrease when breast tissue is in a heterogeneous background. Therefore, SWE should be performed carefully in these cases. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  18. High-resolution morphological and biochemical imaging of articular cartilage of the ankle joint at 3.0 T using a new dedicated phased array coil: in vivo reproducibility study

    International Nuclear Information System (INIS)

    Welsch, Goetz H.; Trattnig, Siegfried; Mamisch, Tallal C.; Weber, Michael; Horger, Wilhelm; Bohndorf, Klaus

    2008-01-01

    The objective of this study was to evaluate the feasibility and reproducibility of high-resolution magnetic resonance imaging (MRI) and quantitative T2 mapping of the talocrural cartilage within a clinically applicable scan time using a new dedicated ankle coil and high-field MRI. Ten healthy volunteers (mean age 32.4 years) underwent MRI of the ankle. As morphological sequences, proton density fat-suppressed turbo spin echo (PD-FS-TSE), as a reference, was compared with 3D true fast imaging with steady-state precession (TrueFISP). Furthermore, biochemical quantitative T2 imaging was prepared using a multi-echo spin-echo T2 approach. Data analysis was performed three times each by three different observers on sagittal slices, planned on the isotropic 3D-TrueFISP; as a morphological parameter, cartilage thickness was assessed and for T2 relaxation times, region-of-interest (ROI) evaluation was done. Reproducibility was determined as a coefficient of variation (CV) for each volunteer; averaged as root mean square (RMSA) given as a percentage; statistical evaluation was done using analysis of variance. Cartilage thickness of the talocrural joint showed significantly higher values for the 3D-TrueFISP (ranging from 1.07 to 1.14 mm) compared with the PD-FS-TSE (ranging from 0.74 to 0.99 mm); however, both morphological sequences showed comparable good results with RMSA of 7.1 to 8.5%. Regarding quantitative T2 mapping, measurements showed T2 relaxation times of about 54 ms with an excellent reproducibility (RMSA) ranging from 3.2 to 4.7%. In our study the assessment of cartilage thickness and T2 relaxation times could be performed with high reproducibility in a clinically realizable scan time, demonstrating new possibilities for further investigations into patient groups. (orig.)

  19. A comparison between laser-doppler imaging and colorimetry in the assessment of scarring: "a pilot study".

    Science.gov (United States)

    Peeters, Wouter; Anthonissen, Mieke; Deliaert, An; Van der Hulst, Rene; Van den Kerckhove, Eric

    2012-05-01

    This cross-sectional pilot-study investigated the reproducibility of the LDI (Moor-LDI-B2; Moor Instruments) and the chromameter (Minolta chromameter CR-300) when used in scar assessment. Twenty-seven scars in 14 subjects were included between January and June 2003. One observer performed two times both measurements with 10 min apart. The intra-observer agreement is quantified by means of the intra-class correlations (ICC) and the standard errors of measurement (SEM) for both the LDI and the chromameter. Ignoring one outlier, the ICC of the LDI = 0.856 and the SEM = 34.56. The chromameter shows a better reproducibility with an ICC of 0.93 and a SEM of 0.79. This pilot-study with a limited number of measurements shows a moderate reproducibility of the LDI compared to the chromameter measurements, in the assessment of respectively flux and redness in scars. © 2011 John Wiley & Sons A/S.

  20. The reproducibility of 31-phosphorus MRS measures of muscle energetics at 3 Tesla in trained men.

    Directory of Open Access Journals (Sweden)

    Lindsay M Edwards

    Full Text Available OBJECTIVE: Magnetic resonance spectroscopy (MRS provides an exceptional opportunity for the study of in vivo metabolism. MRS is widely used to measure phosphorus metabolites in trained muscle, although there are no published data regarding its reproducibility in this specialized cohort. Thus, the aim of this study was to assess the reproducibility of (31P-MRS in trained skeletal muscle. METHODS: We recruited fifteen trained men (VO(2peak = 4.7±0.8 L min(-1/58±8 mL kg(-1 min(-1 and performed duplicate MR experiments during plantar flexion exercise, three weeks apart. RESULTS: Measures of resting phosphorus metabolites were reproducible, with 1.7 mM the smallest detectable difference in phosphocreatine (PCr. Measures of metabolites during exercise were less reliable: exercising PCr had a coefficient of variation (CV of 27% during exercise, compared with 8% at rest. Estimates of mitochondrial function were variable, but experimentally useful. The CV of PCr(1/2t was 40%, yet much of this variance was inter-subject such that differences of <20% were detectable with n = 15, given a significance threshold of p<0.05. CONCLUSIONS: 31-phosphorus MRS provides reproducible and experimentally useful measures of phosphorus metabolites and mitochondrial function in trained human skeletal muscle.

  1. Testing Reproducibility in Earth Sciences

    Science.gov (United States)

    Church, M. A.; Dudill, A. R.; Frey, P.; Venditti, J. G.

    2017-12-01

    Reproducibility represents how closely the results of independent tests agree when undertaken using the same materials but different conditions of measurement, such as operator, equipment or laboratory. The concept of reproducibility is fundamental to the scientific method as it prevents the persistence of incorrect or biased results. Yet currently the production of scientific knowledge emphasizes rapid publication of previously unreported findings, a culture that has emerged from pressures related to hiring, publication criteria and funding requirements. Awareness and critique of the disconnect between how scientific research should be undertaken, and how it actually is conducted, has been prominent in biomedicine for over a decade, with the fields of economics and psychology more recently joining the conversation. The purpose of this presentation is to stimulate the conversation in earth sciences where, despite implicit evidence in widely accepted classifications, formal testing of reproducibility is rare.As a formal test of reproducibility, two sets of experiments were undertaken with the same experimental procedure, at the same scale, but in different laboratories. Using narrow, steep flumes and spherical glass beads, grain size sorting was examined by introducing fine sediment of varying size and quantity into a mobile coarse bed. The general setup was identical, including flume width and slope; however, there were some variations in the materials, construction and lab environment. Comparison of the results includes examination of the infiltration profiles, sediment mobility and transport characteristics. The physical phenomena were qualitatively reproduced but not quantitatively replicated. Reproduction of results encourages more robust research and reporting, and facilitates exploration of possible variations in data in various specific contexts. Following the lead of other fields, testing of reproducibility can be incentivized through changes to journal

  2. Use of three-dimensional speckle tracking to assess left ventricular myocardial mechanics: inter-vendor consistency and reproducibility of strain measurements.

    Science.gov (United States)

    Badano, Luigi P; Cucchini, Umberto; Muraru, Denisa; Al Nono, Osama; Sarais, Cristiano; Iliceto, Sabino

    2013-03-01

    Since there is insufficient data available about the inter-vendor consistency of three-dimensional (3D) speckle-tracking (STE) measurements, we undertook this study to (i) assess the inter-vendor consistency of 3D LV global strain values obtained using two different scanners; (ii) identify the sources of inter-vendor inconsistencies, if any; and (iii) compare their respective intrinsic variability. Sixty patients (38 ± 12 years, 64% males) with a wide range of LV end-diastolic volumes (from 74 to 205 ml) and ejection fractions (from 17 to 70%) underwent two 3D LV data set acquisitions using VividE9 and Artida ultrasound systems. Global longitudinal (Lε), radial (Rε), circumferential (Cε) and area (Aε) strain values were obtained offline using the corresponding 3D STE softwares. Despite being significantly different, Lε showed the closest values between the two platforms (bias = 1.5%, limits of agreement (LOA) from -2.9 to -5.9%, P < 0.05). Artida produced significantly higher values of both Cε and Aε than VividE9 (bias = 6.6, LOA: -14.1 to 0.9%, and bias = 6.0, LOA = -28.2-8.6%, respectively, P < 0.001). Conversely, Rε values obtained with Artida were significantly lower than those measured using VividE9 platform (bias = -24.2, LOA: 1.5-49.9, P < 0.001). All strain components showed good reproducibility (intra-class correlation coefficients: 0.82-0.98), except for Rε by Artida, which showed only a moderate reproducibility. Apart from Lε, the inter-vendor agreement of Rε, Cε and Aε measured with Artida and VividE9 was poor. Reference values should be specific for each system and baseline and follow-up data in longitudinal studies should be obtained using the same 3D STE platform.

  3. Reproducibility of intrarenal kinetics of Gd-DOTA with rabbits with dynamic MRI

    International Nuclear Information System (INIS)

    Grenier, N.; Broussin, J.; Barat, J.L.; Ducassou, D.

    1989-01-01

    Ten normal rabbits and seven rabbits with experimental acute renal failure by tubular necrosis were studied with dynamic MR to evaluate the reproducibility of intrarenal kinetics of Gd-DOTA. Sequential spin-echo sequences with short TR (200 msec)/TE (26 msec) were used yielding a 29 sec acquisition time. A usual semi-quantitative analysis of intrarenal contrast demonstrated the reproducilibity of some phases of the dynamic sequence in particular a drop in the signal within inner medulla between the third and the fourth minute after infusion. This effect, related to a high concentration of Gd-DOTA within the tubules was observed in 9 over 10 normal rabbits and in none of the rabbits with acute renal failure. The quantitative analysis calculation was based on relative signal intensity and contrast-to-noise ratio from the absolute signal intensity measure on regions-of-interest (ROI) on the cortex, outer medulla and inner medulla. No reproducibility of the variations with time of these parameters could be assessed. A gread number of factors of variations or error, mainly during the measurements of signal intensity with ROI, could explain this lack of reproducibility. At the present, dynamic MR is therefore not able to quantitatively evaluate the renal function. Only a semi-quantitative estimation of tubular concentration can be deduced [fr

  4. Metabolic imaging of human kidney triglyceride content: reproducibility of proton magnetic resonance spectroscopy.

    Directory of Open Access Journals (Sweden)

    Sebastiaan Hammer

    Full Text Available OBJECTIVE: To assess the feasibility of renal proton magnetic resonance spectroscopy for quantification of triglyceride content and to compare spectral quality and reproducibility without and with respiratory motion compensation in vivo. MATERIALS AND METHODS: The Institutional Review Board of our institution approved the study protocol, and written informed consent was obtained. After technical optimization, a total of 20 healthy volunteers underwent renal proton magnetic resonance spectroscopy of the renal cortex both without and with respiratory motion compensation and volume tracking. After the first session the subjects were repositioned and the protocol was repeated to assess reproducibility. Spectral quality (linewidth of the water signal and triglyceride content were quantified. Bland-Altman analyses and a test by Pitman were performed. RESULTS: Linewidth changed from 11.5±0.4 Hz to 10.7±0.4 Hz (all data pooled, p<0.05, without and with respiratory motion compensation respectively. Mean % triglyceride content in the first and second session without respiratory motion compensation were respectively 0.58±0.12% and 0.51±0.14% (P = NS. Mean % triglyceride content in the first and second session with respiratory motion compensation were respectively 0.44±0.10% and 0.43±0.10% (P = NS between sessions and P = NS compared to measurements with respiratory motion compensation. Bland-Altman analyses showed narrower limits of agreement and a significant difference in the correlated variances (correlation of -0.59, P<0.05. CONCLUSION: Metabolic imaging of the human kidney using renal proton magnetic resonance spectroscopy is a feasible tool to assess cortical triglyceride content in humans in vivo and the use of respiratory motion compensation significantly improves spectral quality and reproducibility. Therefore, respiratory motion compensation seems a necessity for metabolic imaging of renal triglyceride content in vivo.

  5. Estimating the reproducibility of psychological science

    NARCIS (Netherlands)

    Anderson, Joanna E.; Aarts, Alexander A.; Anderson, Christopher J.; Attridge, Peter R.; Attwood, Angela; Axt, Jordan; Babel, Molly; Bahník, Štěpán; Baranski, Erica; Barnett-Cowan, Michael; Bartmess, Elizabeth; Beer, Jennifer; Bell, Raoul; Bentley, Heather; Beyan, Leah; Binion, Grace; Borsboom, Denny; Bosch, Annick; Bosco, Frank A.; Bowman, Sara D.; Brandt, Mark J.; Braswell, Erin; Brohmer, Hilmar; Brown, Benjamin T.; Brown, Kristina; Brüning, Jovita; Calhoun-Sauls, Ann; Callahan, Shannon P.; Chagnon, Elizabeth; Chandler, Jesse; Chartier, Christopher R.; Cheung, Felix; Christopherson, Cody D.; Cillessen, Linda; Clay, Russ; Cleary, Hayley; Cloud, Mark D.; Conn, Michael; Cohoon, Johanna; Columbus, Simon; Cordes, Andreas; Costantini, Giulio; Alvarez, Leslie D Cramblet; Cremata, Ed; Crusius, Jan; DeCoster, Jamie; DeGaetano, Michelle A.; Penna, Nicolás Delia; Den Bezemer, Bobby; Deserno, Marie K.; Devitt, Olivia; Dewitte, Laura; Dobolyi, David G.; Dodson, Geneva T.; Donnellan, M. Brent; Donohue, Ryan; Dore, Rebecca A.; Dorrough, Angela; Dreber, Anna; Dugas, Michelle; Dunn, Elizabeth W.; Easey, Kayleigh; Eboigbe, Sylvia; Eggleston, Casey; Embley, Jo; Epskamp, Sacha; Errington, Timothy M.; Estel, Vivien; Farach, Frank J.; Feather, Jenelle; Fedor, Anna; Fernández-Castilla, Belén; Fiedler, Susann; Field, James G.; Fitneva, Stanka A.; Flagan, Taru; Forest, Amanda L.; Forsell, Eskil; Foster, Joshua D.; Frank, Michael C.; Frazier, Rebecca S.; Fuchs, Heather; Gable, Philip; Galak, Jeff; Galliani, Elisa Maria; Gampa, Anup; Garcia, Sara; Gazarian, Douglas; Gilbert, Elizabeth; Giner-Sorolla, Roger; Glöckner, Andreas; Goellner, Lars; Goh, Jin X.; Goldberg, Rebecca; Goodbourn, Patrick T.; Gordon-McKeon, Shauna; Gorges, Bryan; Gorges, Jessie; Goss, Justin; Graham, Jesse; Grange, James A.; Gray, Jeremy; Hartgerink, Chris; Hartshorne, Joshua; Hasselman, Fred; Hayes, Timothy; Heikensten, Emma; Henninger, Felix; Hodsoll, John; Holubar, Taylor; Hoogendoorn, Gea; Humphries, Denise J.; Hung, Cathy O Y; Immelman, Nathali; Irsik, Vanessa C.; Jahn, Georg; Jäkel, Frank; Jekel, Marc; Johannesson, Magnus; Johnson, Larissa G.; Johnson, David J.; Johnson, Kate M.; Johnston, William J.; Jonas, Kai; Joy-Gaba, Jennifer A.; Kappes, Heather Barry; Kelso, Kim; Kidwell, Mallory C.; Kim, Seung Kyung; Kirkhart, Matthew; Kleinberg, Bennett; Knežević, Goran; Kolorz, Franziska Maria; Kossakowski, Jolanda J.; Krause, Robert Wilhelm; Krijnen, Job; Kuhlmann, Tim; Kunkels, Yoram K.; Kyc, Megan M.; Lai, Calvin K.; Laique, Aamir; Lakens, Daniël|info:eu-repo/dai/nl/298811855; Lane, Kristin A.; Lassetter, Bethany; Lazarević, Ljiljana B.; Le Bel, Etienne P.; Lee, Key Jung; Lee, Minha; Lemm, Kristi; Levitan, Carmel A.; Lewis, Melissa; Lin, Lin; Lin, Stephanie; Lippold, Matthias; Loureiro, Darren; Luteijn, Ilse; MacKinnon, Sean; Mainard, Heather N.; Marigold, Denise C.; Martin, Daniel P.; Martinez, Tylar; Masicampo, E. J.; Matacotta, Josh; Mathur, Maya; May, Michael; Mechin, Nicole; Mehta, Pranjal; Meixner, Johannes; Melinger, Alissa; Miller, Jeremy K.; Miller, Mallorie; Moore, Katherine; Möschl, Marcus; Motyl, Matt; Müller, Stephanie M.; Munafo, Marcus; Neijenhuijs, Koen I.; Nervi, Taylor; Nicolas, Gandalf; Nilsonne, Gustav; Nosek, Brian A.; Nuijten, Michèle B.; Olsson, Catherine; Osborne, Colleen; Ostkamp, Lutz; Pavel, Misha; Penton-Voak, Ian S.; Perna, Olivia; Pernet, Cyril; Perugini, Marco; Pipitone, R. Nathan; Pitts, Michael; Plessow, Franziska; Prenoveau, Jason M.; Rahal, Rima Maria; Ratliff, Kate A.; Reinhard, David; Renkewitz, Frank; Ricker, Ashley A.; Rigney, Anastasia; Rivers, Andrew M.; Roebke, Mark; Rutchick, Abraham M.; Ryan, Robert S.; Sahin, Onur; Saide, Anondah; Sandstrom, Gillian M.; Santos, David; Saxe, Rebecca; Schlegelmilch, René; Schmidt, Kathleen; Scholz, Sabine; Seibel, Larissa; Selterman, Dylan Faulkner; Shaki, Samuel; Simpson, William B.; Sinclair, H. Colleen; Skorinko, Jeanine L M; Slowik, Agnieszka; Snyder, Joel S.; Soderberg, Courtney; Sonnleitner, Carina; Spencer, Nick; Spies, Jeffrey R.; Steegen, Sara; Stieger, Stefan; Strohminger, Nina; Sullivan, Gavin B.; Talhelm, Thomas; Tapia, Megan; Te Dorsthorst, Anniek; Thomae, Manuela; Thomas, Sarah L.; Tio, Pia; Traets, Frits; Tsang, Steve; Tuerlinckx, Francis; Turchan, Paul; Valášek, Milan; Van't Veer, Anna E.; Van Aert, Robbie; Van Assen, Marcel|info:eu-repo/dai/nl/407629971; Van Bork, Riet; Van De Ven, Mathijs; Van Den Bergh, Don; Van Der Hulst, Marije; Van Dooren, Roel; Van Doorn, Johnny; Van Renswoude, Daan R.; Van Rijn, Hedderik; Vanpaemel, Wolf; Echeverría, Alejandro Vásquez; Vazquez, Melissa; Velez, Natalia; Vermue, Marieke; Verschoor, Mark; Vianello, Michelangelo; Voracek, Martin; Vuu, Gina; Wagenmakers, Eric Jan; Weerdmeester, Joanneke; Welsh, Ashlee; Westgate, Erin C.; Wissink, Joeri; Wood, Michael; Woods, Andy; Wright, Emily; Wu, Sining; Zeelenberg, Marcel; Zuni, Kellylynn

    2015-01-01

    Reproducibility is a defining feature of science, but the extent to which it characterizes current research is unknown. We conducted replications of 100 experimental and correlational studies published in three psychology journals using high-powered designs and original materials when available.

  6. Reproducibility and comparative validity of a food frequency questionnaire for Australian adults.

    Science.gov (United States)

    Collins, Clare E; Boggess, May M; Watson, Jane F; Guest, Maya; Duncanson, Kerith; Pezdirc, Kristine; Rollo, Megan; Hutchesson, Melinda J; Burrows, Tracy L

    2014-10-01

    Food frequency questionnaires (FFQ) are used in epidemiological studies to investigate the relationship between diet and disease. There is a need for a valid and reliable adult FFQ with a contemporary food list in Australia. To evaluate the reproducibility and comparative validity of the Australian Eating Survey (AES) FFQ in adults compared to weighed food records (WFRs). Two rounds of AES and three-day WFRs were conducted in 97 adults (31 males, median age and BMI for males of 44.9 years, 26.2 kg/m(2), females 41.3 years, 24.0 kg/m(2). Reproducibility was assessed over six months using Wilcoxon signed-rank tests and comparative validity was assessed by intraclass correlation coefficients (ICC) estimated by fitting a mixed effects model for each nutrient to account for age, sex and BMI to allow estimation of between and within person variance. Reproducibility was found to be good for both WFR and FFQ since there were no significant differences between round 1 and 2 administrations. For comparative validity, FFQ ICCs were at least as large as those for WFR. The ICC of the WFR-FFQ difference for total energy intake was 0.6 (95% CI 0.43, 0.77) and the median ICC for all nutrients was 0.47, with all ICCs between 0.15 (%E from saturated fat) and 0.7 (g/day sugars). Compared to WFR the AES FFQ is suitable for reliably estimating the dietary intakes of Australian adults across a wide range of nutrients. Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  7. Step-to-step reproducibility and asymmetry to study gait auto-optimization in healthy and cerebral palsied subjects.

    Science.gov (United States)

    Descatoire, A; Femery, V; Potdevin, F; Moretto, P

    2009-05-01

    The purpose of our study was to compare plantar pressure asymmetry and step-to-step reproducibility in both able-bodied persons and two groups of hemiplegics. The relevance of the research was to determine the efficiency of asymmetry and reproducibility as indexes for diagnosis and rehabilitation processes. This study comprised 31 healthy young subjects and 20 young subjects suffering from cerebral palsy hemiplegia assigned to two groups of 10 subjects according to the severity of their musculoskeletal disorders. The peaks of plantar pressure and the time to peak pressure were recorded with an in-shoe measurement system. The intra-individual coefficient of variability was calculated to indicate the consistency of plantar pressure during walking and to define gait stability. The effect size was computed to quantify the asymmetry and measurements were conducted at eight footprint locations. Results indicated few differences in step-to-step reproducibility between the healthy group and the less spastic group while the most affected group showed a more asymmetrical and unstable gait. From the concept of self-optimisation and depending on the neuromotor disorders the organism could make priorities based on pain, mobility, stability or energy expenditure to develop the best gait auto-optimisation.

  8. Multichannel electrogastrography under a magnifying glass--an in-depth study on reproducibility of fed state electrogastrograms.

    Science.gov (United States)

    Krusiec-Swidergoł, B; Jonderko, K

    2008-06-01

    We checked on reproducibility of parameters of a multichannel electrogastrogram in adults after intake of typical, applied in electrogastrography, test meals. Recordings of multichannel electrogastrograms were accomplished in four blocks comprising 18 subjects (nine healthy volunteers and nine patients with functional GI disorders) each. Every subject had two examinations taken 1-2 days apart, and a third one was accomplished at least 2 weeks before or after the two other sessions. The registration involved a 30-min fasted and a 2-h postprandial period after one of the meal stimuli tested within a given block: 400 mL water, 400 g yoghurt (378 kcal), a scrambled eggs sandwich (370 kcal), a pancake (355 kcal). From among the parameters reflecting the propagation of the gastric slow waves, the average percentage of slow wave coupling (APSWC) exhibited a good (coefficient of variation for paired examinations CV(p) < or = 10%) to moderate (10 < CV(p) < or = 30%) reproducibility. On the other hand, the reproducibility of the maximum dominant frequency difference and the spatial dominant power difference was found to be unsatisfactory. The reproducibility of the multichannel electrogastrographic parameters did not differ between healthy volunteers and patients with functional GI disorders. Gender or the kind of a test meal did not affect the reproducibility of the electrogastrographic parameters either. The medium-term reproducibility was not any worse than the short-term one. From among the parameters of a multichannel electrogastrogram intended to quantify the propagation of slow waves, only the APSWC offers a reproducibility potentially good enough for clinical applications.

  9. Systems-based biological concordance and predictive reproducibility of gene set discovery methods in cardiovascular disease.

    Science.gov (United States)

    Azuaje, Francisco; Zheng, Huiru; Camargo, Anyela; Wang, Haiying

    2011-08-01

    The discovery of novel disease biomarkers is a crucial challenge for translational bioinformatics. Demonstration of both their classification power and reproducibility across independent datasets are essential requirements to assess their potential clinical relevance. Small datasets and multiplicity of putative biomarker sets may explain lack of predictive reproducibility. Studies based on pathway-driven discovery approaches have suggested that, despite such discrepancies, the resulting putative biomarkers tend to be implicated in common biological processes. Investigations of this problem have been mainly focused on datasets derived from cancer research. We investigated the predictive and functional concordance of five methods for discovering putative biomarkers in four independently-generated datasets from the cardiovascular disease domain. A diversity of biosignatures was identified by the different methods. However, we found strong biological process concordance between them, especially in the case of methods based on gene set analysis. With a few exceptions, we observed lack of classification reproducibility using independent datasets. Partial overlaps between our putative sets of biomarkers and the primary studies exist. Despite the observed limitations, pathway-driven or gene set analysis can predict potentially novel biomarkers and can jointly point to biomedically-relevant underlying molecular mechanisms. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Reproducibility of thoracic kyphosis measurements in patients with adolescent idiopathic scoliosis.

    Science.gov (United States)

    Ohrt-Nissen, Søren; Cheung, Jason Pui Yin; Hallager, Dennis Winge; Gehrchen, Martin; Kwan, Kenny; Dahl, Benny; Cheung, Kenneth M C; Samartzis, Dino

    2017-01-01

    Current surgical treatment for adolescent idiopathic scoliosis (AIS) involves correction in both the coronal and sagittal plane, and thorough assessment of these parameters is essential for evaluation of surgical results. However, various definitions of thoracic kyphosis (TK) have been proposed, and the intra- and inter-rater reproducibility of these measures has not been determined. As such, the purpose of the current study was to determine the intra- and inter-rater reproducibility of several TK measurements used in the assessment of AIS. Twenty patients (90% females) surgically treated for AIS with alternate-level pedicle screw fixation were included in the study. Three raters independently evaluated pre- and postoperative standing lateral plain radiographs. For each radiograph, several definitions of TK were measured as well as L1-S1 and nonfixed lumbar lordosis. All variables were measured twice 14 days apart, and a mixed effects model was used to determine the repeatability coefficient (RC), which is a measure of the agreement between repeated measurements. Also, the intra- and inter-rater intra-class correlation coefficient (ICC) was determined as a measure of reliability. Preoperative median Cobb angle was 58° (range 41°-86°), and median surgical curve correction was 68% (range 49-87%). Overall intra-rater RC was highest for T2-T12 and nonfixed TK (11°) and lowest for T4-T12 and T5-T12 (8°). Inter-rater RC was highest for T1-T12, T1-nonfixed, and nonfixed TK (13°) and lowest for T5-T12 (9°). Agreement varied substantially between pre- and postoperative radiographs. Inter-rater ICC was highest for T4-T12 (0.92; 95% CI 0.88-0.95) and T5-T12 (0.92; 95% CI 0.88-0.95) and lowest for T1-nonfixed (0.80; 95% CI 0.72-0.88). Considerable variation for all TK measurements was noted. Intra- and inter-rater reproducibility was best for T4-T12 and T5-T12. Future studies should consider adopting a relevant minimum difference as a limit for true change in TK.

  11. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier

    2010-01-01

    Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated...... and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing...

  12. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben; Mouridsen, Kim; Golay, Xavier

    2009-01-01

    Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated...... and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing...

  13. Urethral pressure reflectometry in women with pelvic organ prolapse: a study of reproducibility.

    Science.gov (United States)

    Khayyami, Yasmine; Lose, Gunnar; Klarskov, Niels

    2017-05-01

    The mechanism of continence in women with pelvic organ prolapse (POP) before and after surgery remains unknown. Urethral pressure reflectometry (UPR) separates women with stress urinary incontinence (SUI) from continent women by measuring urethral opening pressure at an abdominal pressure of 50 cmH 2 O (P O-Abd 50 ). UPR can help identify women with POP at risk of postoperative de novo SUI. The aim of this study was to investigate the reproducibility of UPR in women with POP. Women with anterior or posterior vaginal wall prolapse were recruited for this prospective, observational study from our outpatient clinic. The women were examined with UPR on two occasions. Measurements were done at rest, and during squeezing and straining. Statistical analyses were performed using SAS 9.4. A Bland-Altman analysis with limits of agreement and coefficients of variation was used to determine the level of agreement between measurements. Paired t tests were used to estimate the difference; a two-tailed P value of rest or during squeezing or in the values of P O-Abd 50 . P O-Abd 50 showed limits of agreement of 15.3 cmH 2 O and a coefficient of variation of 9.9 %. UPR was found to be a highly reproducible method in women with POP. UPR may be used in future studies to help reveal urodynamic features predictive of postoperative de novo SUI in women with POP.

  14. A network-based method to evaluate quality of reproducibility of differential expression in cancer genomics studies.

    Science.gov (United States)

    Li, Robin; Lin, Xiao; Geng, Haijiang; Li, Zhihui; Li, Jiabing; Lu, Tao; Yan, Fangrong

    2015-12-29

    Personalized cancer treatments depend on the determination of a patient's genetic status according to known genetic profiles for which targeted treatments exist. Such genetic profiles must be scientifically validated before they is applied to general patient population. Reproducibility of findings that support such genetic profiles is a fundamental challenge in validation studies. The percentage of overlapping genes (POG) criterion and derivative methods produce unstable and misleading results. Furthermore, in a complex disease, comparisons between different tumor subtypes can produce high POG scores that do not capture the consistencies in the functions. We focused on the quality rather than the quantity of the overlapping genes. We defined the rank value of each gene according to importance or quality by PageRank on basis of a particular topological structure. Then, we used the p-value of the rank-sum of the overlapping genes (PRSOG) to evaluate the quality of reproducibility. Though the POG scores were low in different studies of the same disease, the PRSOG was statistically significant, which suggests that sets of differentially expressed genes might be highly reproducible. Evaluations of eight datasets from breast cancer, lung cancer and four other disorders indicate that quality-based PRSOG method performs better than a quantity-based method. Our analysis of the components of the sets of overlapping genes supports the utility of the PRSOG method.

  15. Reproducibility of clinical research in critical care: a scoping review.

    Science.gov (United States)

    Niven, Daniel J; McCormick, T Jared; Straus, Sharon E; Hemmelgarn, Brenda R; Jeffs, Lianne; Barnes, Tavish R M; Stelfox, Henry T

    2018-02-21

    The ability to reproduce experiments is a defining principle of science. Reproducibility of clinical research has received relatively little scientific attention. However, it is important as it may inform clinical practice, research agendas, and the design of future studies. We used scoping review methods to examine reproducibility within a cohort of randomized trials examining clinical critical care research and published in the top general medical and critical care journals. To identify relevant clinical practices, we searched the New England Journal of Medicine, The Lancet, and JAMA for randomized trials published up to April 2016. To identify a comprehensive set of studies for these practices, included articles informed secondary searches within other high-impact medical and specialty journals. We included late-phase randomized controlled trials examining therapeutic clinical practices in adults admitted to general medical-surgical or specialty intensive care units (ICUs). Included articles were classified using a reproducibility framework. An original study was the first to evaluate a clinical practice. A reproduction attempt re-evaluated that practice in a new set of participants. Overall, 158 practices were examined in 275 included articles. A reproduction attempt was identified for 66 practices (42%, 95% CI 33-50%). Original studies reported larger effects than reproduction attempts (primary endpoint, risk difference 16.0%, 95% CI 11.6-20.5% vs. 8.4%, 95% CI 6.0-10.8%, P = 0.003). More than half of clinical practices with a reproduction attempt demonstrated effects that were inconsistent with the original study (56%, 95% CI 42-68%), among which a large number were reported to be efficacious in the original study and to lack efficacy in the reproduction attempt (34%, 95% CI 19-52%). Two practices reported to be efficacious in the original study were found to be harmful in the reproduction attempt. A minority of critical care practices with research published

  16. Intra- and inter-observer reproducibility and generalizability of first trimester uterine artery pulsatility index by transabdominal and transvaginal ultrasound

    NARCIS (Netherlands)

    Marchi, Laura; Zwertbroek, Eva; Snelder, Judith; Kloosterman, Maaike; Bilardo, Caterina Maddalena

    2016-01-01

    Objectives The primary aim of the study was to assess intra-observer and inter-observer reproducibility and generalizability (general reliability) of first trimester Doppler measurements of uterine arteries (UtA) performed both transabdominally (TA) and transvaginally (TV). Secondary aims were to

  17. Intravoxel incoherent motion diffusion imaging of the liver: Optimal b-value subsampling and impact on parameter precision and reproducibility

    International Nuclear Information System (INIS)

    Dyvorne, Hadrien; Jajamovich, Guido; Kakite, Suguru; Kuehn, Bernd; Taouli, Bachir

    2014-01-01

    Highlights: • We assess the precision and reproducibility of liver IVIM diffusion parameters. • Liver IVIM DWI can be performed with 4 b-values with good parameter precision. • Liver IVIM DWI can be performed with 4 b-values with good parameter reproducibility. - Abstract: Purpose: To increase diffusion sampling efficiency in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver by reducing the number of diffusion weightings (b-values). Materials and methods: In this IRB approved HIPAA compliant prospective study, 53 subjects (M/F 38/15, mean age 52 ± 13 y) underwent IVIM DWI at 1.5 T using 16 b-values (0–800 s/mm 2 ), with 14 subjects having repeat exams to assess IVIM parameter reproducibility. A biexponential diffusion model was used to quantify IVIM hepatic parameters (PF: perfusion fraction, D: true diffusion and D*: pseudo diffusion). All possible subsets of the 16 b-values were probed, with number of b values ranging from 4 to 15, and corresponding parameters were quantified for each subset. For each b-value subset, global parameter estimation error was computed against the parameters obtained with all 16 b-values and the subsets providing the lowest error were selected. Interscan estimation error was also evaluated between repeat exams to assess reproducibility of the IVIM technique in the liver. The optimal b-values distribution was selected such that the number of b-values was minimal while keeping parameter estimation error below interscan reproducibility error. Results: As the number of b-values decreased, the estimation error increased for all parameters, reflecting decreased precision of IVIM metrics. Using an optimal set of 4 b-values (0, 15, 150 and 800 s/mm 2 ), the errors were 6.5, 22.8 and 66.1% for D, PF and D* respectively. These values lie within the range of test–retest reproducibility for the corresponding parameters, with errors of 12.0, 32.3 and 193.8% for D, PF and D* respectively. Conclusion: A set

  18. Reproducibility of the interpretation of coronal 3D ultrasound view of the uterus to evaluate the position of Essure® 3 months after hysteroscopic procedure.

    Science.gov (United States)

    Capmas, P; Letendre, I; Levaillant, J-M; Fuchs, F; Panel, P; Chambon, G; Villefranque, V; Levy-Zauberman, Y; Fernandez, H

    2017-09-01

    Three-dimensional sonography is a good alternative method to assess the position of microinserts. Adequate position after three months allows for the interruption of other contraception. Objective is to evaluate inter-observer reproducibility of the interpretation of coronal transvaginal 3D ultrasound view of the uterus to evaluate the position of Essure ® . Inter-observer reproducibility study. Fifty women underwent successful bilateral placement of microinserts (Essure ® ) by hysteroscopy in the Department of Gynaecology of a teaching hospital and were included in the study. At three month, 3D ultrasound coronal views of the fifty uterus (accounting for one hundred microinserts) were assessed by five different observers and microinsert position was classified according to the classification described by Legendre et al. Inter-observer reproducibility in reading the 3D coronal view of the uterus was evaluated. The k-value was disparate, from 0.26 to 0.82. Inter-observer reproducibility then ranged from fair to almost perfect, depending on a prior knowledge of the position classification. Transvaginal 3D coronal view of the uterus is sufficient to assess the positioning of the microinserts when the practionner or the surgeon is familiar with the classification method. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Repeatability and reproducibility of Population Viability Analysis (PVA and the implications for threatened species management

    Directory of Open Access Journals (Sweden)

    Clare Morrison

    2016-08-01

    Full Text Available Conservation triage focuses on prioritizing species, populations or habitats based on urgency, biodiversity benefits, recovery potential as well as cost. Population Viability Analysis (PVA is frequently used in population focused conservation prioritizations. The critical nature of many of these management decisions requires that PVA models are repeatable and reproducible to reliably rank species and/or populations quantitatively. This paper assessed the repeatability and reproducibility of a subset of previously published PVA models. We attempted to rerun baseline models from 90 publicly available PVA studies published between 2000-2012 using the two most common PVA modelling software programs, VORTEX and RAMAS-GIS. Forty percent (n = 36 failed, 50% (45 were both repeatable and reproducible, and 10% (9 had missing baseline models. Repeatability was not linked to taxa, IUCN category, PVA program version used, year published or the quality of publication outlet, suggesting that the problem is systemic within the discipline. Complete and systematic presentation of PVA parameters and results are needed to ensure that the scientific input into conservation planning is both robust and reliable, thereby increasing the chances of making decisions that are both beneficial and defensible. The implications for conservation triage may be far reaching if population viability models cannot be reproduced with confidence, thus undermining their intended value.

  20. Towards Reproducibility in Computational Hydrology

    Science.gov (United States)

    Hutton, Christopher; Wagener, Thorsten; Freer, Jim; Han, Dawei; Duffy, Chris; Arheimer, Berit

    2017-04-01

    Reproducibility is a foundational principle in scientific research. The ability to independently re-run an experiment helps to verify the legitimacy of individual findings, and evolve (or reject) hypotheses and models of how environmental systems function, and move them from specific circumstances to more general theory. Yet in computational hydrology (and in environmental science more widely) the code and data that produces published results are not regularly made available, and even if they are made available, there remains a multitude of generally unreported choices that an individual scientist may have made that impact the study result. This situation strongly inhibits the ability of our community to reproduce and verify previous findings, as all the information and boundary conditions required to set up a computational experiment simply cannot be reported in an article's text alone. In Hutton et al 2016 [1], we argue that a cultural change is required in the computational hydrological community, in order to advance and make more robust the process of knowledge creation and hypothesis testing. We need to adopt common standards and infrastructures to: (1) make code readable and re-useable; (2) create well-documented workflows that combine re-useable code together with data to enable published scientific findings to be reproduced; (3) make code and workflows available, easy to find, and easy to interpret, using code and code metadata repositories. To create change we argue for improved graduate training in these areas. In this talk we reflect on our progress in achieving reproducible, open science in computational hydrology, which are relevant to the broader computational geoscience community. In particular, we draw on our experience in the Switch-On (EU funded) virtual water science laboratory (http://www.switch-on-vwsl.eu/participate/), which is an open platform for collaboration in hydrological experiments (e.g. [2]). While we use computational hydrology as

  1. Open and reproducible global land use classification

    Science.gov (United States)

    Nüst, Daniel; Václavík, Tomáš; Pross, Benjamin

    2015-04-01

    Researchers led by the Helmholtz Centre for Environmental research (UFZ) developed a new world map of land use systems based on over 30 diverse indicators (http://geoportal.glues.geo.tu-dresden.de/stories/landsystemarchetypes.html) of land use intensity, climate and environmental and socioeconomic factors. They identified twelve land system archetypes (LSA) using a data-driven classification algorithm (self-organizing maps) to assess global impacts of land use on the environment, and found unexpected similarities across global regions. We present how the algorithm behind this analysis can be published as an executable web process using 52°North WPS4R (https://wiki.52north.org/bin/view/Geostatistics/WPS4R) within the GLUES project (http://modul-a.nachhaltiges-landmanagement.de/en/scientific-coordination-glues/). WPS4R is an open source collaboration platform for researchers, analysts and software developers to publish R scripts (http://www.r-project.org/) as a geo-enabled OGC Web Processing Service (WPS) process. The interoperable interface to call the geoprocess allows both reproducibility of the analysis and integration of user data without knowledge about web services or classification algorithms. The open platform allows everybody to replicate the analysis in their own environments. The LSA WPS process has several input parameters, which can be changed via a simple web interface. The input parameters are used to configure both the WPS environment and the LSA algorithm itself. The encapsulation as a web process allows integration of non-public datasets, while at the same time the publication requires a well-defined documentation of the analysis. We demonstrate this platform specifically to domain scientists and show how reproducibility and open source publication of analyses can be enhanced. We also discuss future extensions of the reproducible land use classification, such as the possibility for users to enter their own areas of interest to the system and

  2. Enacting the International/Reproducing Eurocentrism

    Directory of Open Access Journals (Sweden)

    Zeynep Gülşah Çapan

    Full Text Available Abstract This article focuses on the way in which Eurocentric conceptualisations of the ‘international’ are reproduced in different geopolitical contexts. Even though the Eurocentrism of International Relations has received growing attention, it has predominantly been concerned with unearthing the Eurocentrism of the ‘centre’, overlooking its varied manifestations in other geopolitical contexts. The article seeks to contribute to discussions about Eurocentrism by examining how different conceptualisations of the international are at work at a particular moment, and how these conceptualisations continue to reproduce Eurocentrism. It will focus on the way in which Eurocentric designations of spatial and temporal hierarchies were reproduced in the context of Turkey through a reading of how the ‘Gezi Park protests’ of 2013 and ‘Turkey’ itself were written into the story of the international.

  3. A Study of QMM Hysteresis Cycle Data. Field Linearity and Field Reproducibility

    International Nuclear Information System (INIS)

    Vernin, P.; Fonvieille, H.; Quemener, G.

    1997-08-01

    A study of the hysteresis data provided by the quadrupole field mapping of the HRS Electron Arm is presented. For each quad Q1, Q2, Q3, a series of runs was performed to obtain the hysteresis curve of the magnet at maximal current. The focus of the present document is not the field maps but a specific analysis of QMM data in terms of hysteresis curves, and field linearity as a function of the current. These measurements allow to put limits on the reproducibility of magnet setting for the presently used operating mode of the quads. (K.A.)

  4. T2-mapping of the sacroiliac joints at 1.5 Tesla: a feasibility and reproducibility study.

    Science.gov (United States)

    Albano, Domenico; Chianca, Vito; Cuocolo, Renato; Bignone, Rodolfo; Ciccia, Francesco; Sconfienza, Luca Maria; Midiri, Massimo; Brunetti, Arturo; Lagalla, Roberto; Galia, Massimo

    2018-04-20

    To evaluate the reproducibility of T2 relaxation time measurements of the sacroiliac joints at 1.5 T. Healthy volunteers underwent an oblique axial multislice multiecho spin-echo sequence of the sacroiliac joints at 1.5 T. Regions of interest were manually drawn using a dedicated software by two musculoskeletal radiologists to include the cartilaginous part of the sacroiliac joints. A senior radiologist performed the measurement twice, while a resident measured once. Intra- and inter-observer reproducibility was tested using the Bland-Altman method. Association between sex and T2 relaxation times was tested using the Mann-Whitney U test. Correlation between T2 relaxation times and body mass index (BMI) was tested using the Spearman's rho. Eighty sacroiliac joints of 40 subjects (mean age: 28 ± 4.8 years, range: 20-43; mean BMI: 23.3 ± 3.1, range: 18.9-30) were imaged. The mean T2 values obtained by the senior radiologist in the first series of measurements were 42 ± 4.4 ms, whereas in the second series were 40.7 ± 4.5 ms. The mean T2 values obtained by the radiology resident were 41.1 ± 4.2 ms. Intra-observer reproducibility was 88% (coefficient of repeatability = 3.8; bias = 1.28; p sacroiliac joints seems to be highly reproducible at 1.5 T. Further studies could investigate the potential clinical application of this tool in the sacroiliac joints.

  5. Characterization and reproducibility of HepG2 hanging drop spheroids toxicology in vitro.

    Science.gov (United States)

    Hurrell, Tracey; Ellero, Andrea Antonio; Masso, Zelie Flavienne; Cromarty, Allan Duncan

    2018-02-21

    Hepatotoxicity remains a major challenge in drug development despite preclinical toxicity screening using hepatocytes of human origin. To overcome some limitations of reproducing the hepatic phenotype, more structurally and functionally authentic cultures in vitro can be introduced by growing cells in 3D spheroid cultures. Characterisation and reproducibility of HepG2 spheroid cultures using a high-throughput hanging drop technique was performed and features contributing to potential phenotypic variation highlighted. Cultured HepG2 cells were seeded into Perfecta 3D® 96-well hanging drop plates and assessed over time for morphology, viability, cell cycle distribution, protein content and protein-mass profiles. Divergent aspects which were assessed included cell stocks, seeding density, volume of culture medium and use of extracellular matrix additives. Hanging drops are advantageous due to no complex culture matrix being present, enabling background free extractions for downstream experimentation. Varying characteristics were observed across cell stocks and batches, seeding density, culture medium volume and extracellular matrix when using immortalized HepG2 cells. These factors contribute to wide-ranging cellular responses and highlights concerns with respect to generating a reproducible phenotype in HepG2 hanging drop spheroids. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Retrospective Occupational Exposure Assessment in Community-Based Studies Made Easier

    International Nuclear Information System (INIS)

    Fritschi, L.; Girschik, J.; Friesen, M.C.; Glass, D.; Monash, G.B.; Sadkowsky, T.

    2010-01-01

    Occ DEAS Assessing occupational exposure in retrospective community-based case-control studies is difficult as measured exposure data are very seldom available. The expert assessment method is considered the most accurate way to attribute exposure but it is a time consuming and expensive process and may be seen as subjective, non reproducible, and non transparent. In this paper, we describe these problems and outline our solutions as ope rationalized in a web-based software application (Occ DEAS). The novel aspects of Occ DEAS are combining all steps in the assessment into one software package; enmeshing the process of assessment into the development of questionnaires; selecting the exposure(s) of interest; specifying rules for exposure assignment; allowing manual or automatic assessments; ensuring that circumstances in which exposure is possible for an individual are highlighted for review; providing reports to ensure consistency of assessment. Development of this application has the potential to make high-quality occupational assessment more efficient and accessible for epidemiological studies

  7. Reproducibility and relative validity of food group intake in a food frequency questionnaire developed for Nepalese diet.

    Science.gov (United States)

    Shrestha, Archana; Koju, Rajendra Prasad; Beresford, Shirley A A; Chan, Kwun Chuen Gary; Connell, Frederik A; Karmacharya, Biraj Man; Shrestha, Pramita; Fitzpatrick, Annette L

    2017-08-01

    We developed a food frequency questionnaire (FFQ) designed to measure the dietary practices of adult Nepalese. The present study examined the validity and reproducibility of the FFQ. To evaluate the reproducibility of the FFQ, 116 subjects completed two 115-item FFQ across a four-month interval. Six 24-h dietary recalls were collected (1 each month) to assess the validity of the FFQ. Seven major food groups and 23 subgroups were clustered from the FFQ based on macronutrient composition. Spearman correlation coefficients evaluating reproducibility for all food groups were greater than 0.5, with the exceptions of oil. The correlations varied from 0.41 (oil) to 0.81 (vegetables). All crude spearman coefficients for validity were greater than 0.5 except for dairy products, pizzas/pastas and sausage/burgers. The FFQ was found to be reliable and valid for ranking the intake of food groups for Nepalese dietary intake.

  8. A catalyzing phantom for reproducible dynamic conversion of hyperpolarized [1-¹³C]-pyruvate.

    Science.gov (United States)

    Walker, Christopher M; Lee, Jaehyuk; Ramirez, Marc S; Schellingerhout, Dawid; Millward, Steven; Bankson, James A

    2013-01-01

    In vivo real time spectroscopic imaging of hyperpolarized ¹³C labeled metabolites shows substantial promise for the assessment of physiological processes that were previously inaccessible. However, reliable and reproducible methods of measurement are necessary to maximize the effectiveness of imaging biomarkers that may one day guide personalized care for diseases such as cancer. Animal models of human disease serve as poor reference standards due to the complexity, heterogeneity, and transient nature of advancing disease. In this study, we describe the reproducible conversion of hyperpolarized [1-¹³C]-pyruvate to [1-¹³C]-lactate using a novel synthetic enzyme phantom system. The rate of reaction can be controlled and tuned to mimic normal or pathologic conditions of varying degree. Variations observed in the use of this phantom compare favorably against within-group variations observed in recent animal studies. This novel phantom system provides crucial capabilities as a reference standard for the optimization, comparison, and certification of quantitative imaging strategies for hyperpolarized tracers.

  9. A catalyzing phantom for reproducible dynamic conversion of hyperpolarized [1-¹³C]-pyruvate.

    Directory of Open Access Journals (Sweden)

    Christopher M Walker

    Full Text Available In vivo real time spectroscopic imaging of hyperpolarized ¹³C labeled metabolites shows substantial promise for the assessment of physiological processes that were previously inaccessible. However, reliable and reproducible methods of measurement are necessary to maximize the effectiveness of imaging biomarkers that may one day guide personalized care for diseases such as cancer. Animal models of human disease serve as poor reference standards due to the complexity, heterogeneity, and transient nature of advancing disease. In this study, we describe the reproducible conversion of hyperpolarized [1-¹³C]-pyruvate to [1-¹³C]-lactate using a novel synthetic enzyme phantom system. The rate of reaction can be controlled and tuned to mimic normal or pathologic conditions of varying degree. Variations observed in the use of this phantom compare favorably against within-group variations observed in recent animal studies. This novel phantom system provides crucial capabilities as a reference standard for the optimization, comparison, and certification of quantitative imaging strategies for hyperpolarized tracers.

  10. Reproducibility of morphometric X-ray absorptiometry

    International Nuclear Information System (INIS)

    Culton, N.; Pocock, N.

    1999-01-01

    Full text: Morphometric X-ray absorptiometry (MXA) using DXA is potentially a useful clinical tool which may provide additional vertebral fracture information with low radiation exposure. While morphometric analysis is semi-automated, operator intervention is crucial for the accurate positioning of the six data points quantifying the vertebral heights at the anterior, middle and posterior positions. Our study evaluated intra-operator reproducibility of MXA in an elderly patient population and assessed the effect of training and experience on vertebral height precision. Ten patients, with a mean lumbar T score of - 2.07, were studied. Images were processed by a trained operator who had initially only limited morphometric experience. The analysis of the data files were repeated at 2 and 6 weeks, during which time the operator had obtained further experience and training. The intra-operator precision of vertebral height measurements was calculated using the three separate combinations of paired analyses, and expressed as the coefficient of variation. This study confirms the importance of adequate training and attention to detail in MXA analysis. The data indicate that the precision of MXA is adequate for its use in the diagnosis of vertebral fractures, based on a 20% deformity criteria. Use of MXA for monitoring would require approximately an 8% change in vertebral heights to achieve statistical significance

  11. Reproducibility of the World Health Organization 2008 criteria for myelodysplastic syndromes.

    Science.gov (United States)

    Senent, Leonor; Arenillas, Leonor; Luño, Elisa; Ruiz, Juan C; Sanz, Guillermo; Florensa, Lourdes

    2013-04-01

    The reproducibility of the World Health Organization 2008 classification for myelodysplastic syndromes is uncertain and its assessment was the major aim of this study. The different peripheral blood and bone marrow variables required for an adequate morphological classification were blindly evaluated by four cytomorphologists in samples from 50 patients with myelodysplastic syndromes. The degree of agreement among observers was calculated using intraclass correlation coefficient and the generalized kappa statistic for multiple raters. The degree of agreement for the percentages of blasts in bone marrow and peripheral blood, ring sideroblasts in bone marrow, and erythroid, granulocytic and megakaryocytic dysplastic cells was strong (P<0.001 in all instances). After stratifying the percentages according to the categories required for the assignment of World Health Organization subtypes, the degree of agreement was not statistically significant for cases with 5-9% blasts in bone marrow (P=0.07), 0.1-1% blasts in peripheral blood (P=0.47), or percentage of erythroid dysplastic cells (P=0.49). Finally, the interobserver concordance for World Health Organization-defined subtypes showed a moderate overall agreement (P<0.001), the reproducibility being lower for cases with refractory anemia with excess of blasts type 1 (P=0.05) and refractory anemia with ring sideroblasts (P=0.09). In conclusion, the reproducibility of the World Health Organization 2008 classification for myelodysplastic syndromes is acceptable but the defining criteria for blast cells and features of erythroid dysplasia need to be refined.

  12. Interlaboratory Reproducibility of Droplet Digital Polymerase Chain Reaction Using a New DNA Reference Material Format.

    Science.gov (United States)

    Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R

    2017-11-07

    Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.

  13. Translation, cross-cultural adaptation, and reproducibility of the Brazilian portuguese-language version of the Wisconsin Smoking Withdrawal Scale.

    Science.gov (United States)

    Oliveira Junior, Boanerges Lopes de; Jardim, José Roberto; Nascimento, Oliver Augusto; Souza, George Márcio da Costa e; Baker, Timothy B; Santoro, Ilka Lopes

    2012-01-01

    To cross-culturally adapt the Wisconsin Smoking Withdrawal Scale (WSWS) for use in Brazil and evaluate the reproducibility of the new (Brazilian Portuguese-language) version. The original English version of the WSWS was translated into Brazilian Portuguese. For cross-cultural adaptation, the Brazilian Portuguese-language version of the WSWS was administered to eight volunteers, all of whom were smokers. After adjustments had been made, the WSWS version was back-translated into English. The Brazilian Portuguese-language version was thereby found to be accurate. The final Brazilian Portuguese-language version of the WSWS was applied to 75 smokers at three distinct times. For the assessment of interobserver reproducibility, it was applied twice within a 30-min interval by two different interviewers. For the assessment of intraobserver reproducibility, it was applied again 15 days later by one of the interviewers. Intraclass correlation coefficients (ICCs) were used in order to test the concordance of the answers. The significance level was set at p Portuguese-language version of the WSWS is reproducible, fast, and simple. It can therefore be used as a tool for assessing the severity of the symptoms of nicotine withdrawal syndrome.

  14. Reproducibility of surface roughness in reaming

    DEFF Research Database (Denmark)

    Müller, Pavel; De Chiffre, Leonardo

    An investigation on the reproducibility of surface roughness in reaming was performed to document the applicability of this approach for testing cutting fluids. Austenitic stainless steel was used as a workpiece material and HSS reamers as cutting tools. Reproducibility of the results was evaluat...

  15. Comet assay in reconstructed 3D human epidermal skin models—investigation of intra- and inter-laboratory reproducibility with coded chemicals

    Science.gov (United States)

    Pfuhler, Stefan

    2013-01-01

    Reconstructed 3D human epidermal skin models are being used increasingly for safety testing of chemicals. Based on EpiDerm™ tissues, an assay was developed in which the tissues were topically exposed to test chemicals for 3h followed by cell isolation and assessment of DNA damage using the comet assay. Inter-laboratory reproducibility of the 3D skin comet assay was initially demonstrated using two model genotoxic carcinogens, methyl methane sulfonate (MMS) and 4-nitroquinoline-n-oxide, and the results showed good concordance among three different laboratories and with in vivo data. In Phase 2 of the project, intra- and inter-laboratory reproducibility was investigated with five coded compounds with different genotoxicity liability tested at three different laboratories. For the genotoxic carcinogens MMS and N-ethyl-N-nitrosourea, all laboratories reported a dose-related and statistically significant increase (P 30% cell loss), and the overall response was comparable in all laboratories despite some differences in doses tested. The results of the collaborative study for the coded compounds were generally reproducible among the laboratories involved and intra-laboratory reproducibility was also good. These data indicate that the comet assay in EpiDerm™ skin models is a promising model for the safety assessment of compounds with a dermal route of exposure. PMID:24150594

  16. Reproducibility of mass spectrometry based protein profiles for diagnosis of ovarian cancer across clinical studies: A systematic review

    DEFF Research Database (Denmark)

    Callesen, AK; Mogensen, O; Jensen, AK

    2012-01-01

    of published discriminatory peaks to peaks found in an original MALDI MS protein profiling study was made to address the key question of reproducibility across studies. An overlap was found despite substantial heterogeneity between studies relating to study design, biological material, pre-analytical treatment...

  17. Reproducibility over a 1-month period of 1H-MR spectroscopic imaging NAA/Cr ratios in clinically stable multiple sclerosis patients.

    Science.gov (United States)

    Mostert, J P; Blaauw, Y; Koch, M W; Kuiper, A J; Hoogduin, J M; De Keyser, J

    2008-08-01

    N-acetylaspartate/creatine (NAA/Cr) ratios, assessed with proton magnetic resonance spectroscopy, are increasingly used as a surrogate marker for axonal dysfunction and degeneration in multiple sclerosis (MS). The purpose of this study was to test short-time reproducibility of NAA/Cr ratios in patients with clinically stable MS. In 35 MS patients we analysed NAA/Cr ratios obtained with (1)H-MR spectroscopic imaging at the centrum semiovale either with lateral ventricles partially included (group 1; n=15) or more cranially with no ventricles included (group 2; n=20). To test short-term reproducibility of the NAA/Cr measurements, patients were scanned twice 4 weeks apart. We determined mean NAA/Cr and Cho/Cr ratios of 12 grey matter and 24 white matter voxels. Mean NAA/Cr ratios of both the white and grey matter did not change after 4 weeks. Overall 4-week reproducibility of the NAA/Cr ratio, expressed as coefficient of variation, was 4.8% for grey matter and 3.5% for white matter. Reproducibility of cranial scanning of the ventricles was slightly better than with cerebrospinal fluid included. Our study shows good short-term reproducibility of NAA/Cr ratio measurements in the centrum semiovale, which supports the reliability of this technique for longitudinal studies.

  18. Reproducibility of the cutoff probe for the measurement of electron density

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. W.; Oh, W. Y. [Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-701 (Korea, Republic of); You, S. J., E-mail: sjyou@cnu.ac.kr [Department of Physics, Chungnam National University, Daejeon 305-701 (Korea, Republic of); Kwon, J. H.; You, K. H.; Seo, B. H.; Kim, J. H., E-mail: jhkim86@kriss.re.kr [Center for Vacuum Technology, Korea Research Institute of Standards and Science, Daejeon 305-306 (Korea, Republic of); Yoon, J.-S. [Plasma Technology Research Center, National Fusion Research Institute, Gunsan 573-540 (Korea, Republic of)

    2016-06-15

    Since a plasma processing control based on plasma diagnostics attracted considerable attention in industry, the reproducibility of the diagnostics using in this application has become a great interest. Because the cutoff probe is one of the potential candidates for this application, knowing the reproducibility of the cutoff probe measurement becomes quit important in the cutoff probe application research. To test the reproducibility of the cutoff probe measurement, in this paper, a comparative study among the different cutoff probe measurements was performed. The comparative study revealed remarkable result: the cutoff probe has a great reproducibility for the electron density measurement, i.e., there are little differences among measurements by different probes made by different experimenters. The discussion including the reason for the result was addressed via this paper by using a basic measurement principle of cutoff probe and a comparative experiment with Langmuir probe.

  19. Reproducibility of the cutoff probe for the measurement of electron density

    International Nuclear Information System (INIS)

    Kim, D. W.; Oh, W. Y.; You, S. J.; Kwon, J. H.; You, K. H.; Seo, B. H.; Kim, J. H.; Yoon, J.-S.

    2016-01-01

    Since a plasma processing control based on plasma diagnostics attracted considerable attention in industry, the reproducibility of the diagnostics using in this application has become a great interest. Because the cutoff probe is one of the potential candidates for this application, knowing the reproducibility of the cutoff probe measurement becomes quit important in the cutoff probe application research. To test the reproducibility of the cutoff probe measurement, in this paper, a comparative study among the different cutoff probe measurements was performed. The comparative study revealed remarkable result: the cutoff probe has a great reproducibility for the electron density measurement, i.e., there are little differences among measurements by different probes made by different experimenters. The discussion including the reason for the result was addressed via this paper by using a basic measurement principle of cutoff probe and a comparative experiment with Langmuir probe.

  20. Inter-laboratory evaluation of instrument platforms and experimental workflows for quantitative accuracy and reproducibility assessment

    Directory of Open Access Journals (Sweden)

    Andrew J. Percy

    2015-09-01

    Full Text Available The reproducibility of plasma protein quantitation between laboratories and between instrument types was examined in a large-scale international study involving 16 laboratories and 19 LC–MS/MS platforms, using two kits designed to evaluate instrument performance and one kit designed to evaluate the entire bottom-up workflow. There was little effect of instrument type on the quality of the results, demonstrating the robustness of LC/MRM-MS with isotopically labeled standards. Technician skill was a factor, as errors in sample preparation and sub-optimal LC–MS performance were evident. This highlights the importance of proper training and routine quality control before quantitation is done on patient samples.

  1. Reproducibility of temporomandibular joint tomography. Influence of shifted X-ray beam and tomographic focal plane on reproducibility

    International Nuclear Information System (INIS)

    Saito, Masashi

    1999-01-01

    Proper tomographic focal plane and x-ray beam direction are the most important factors to obtain accurate images of the temporomandibular joint (TMJ). In this study, to clarify the magnitude of effect of these two factors on the image quality. We evaluated the reproducibility of tomograms by measuring the distortion when the x-ray beam was shifted from the correct center of the object. The effects of the deviation of the tomographic focal plane on image quality were evaluated by the MTF (Modulation Transfer Function). Two types of tomograms, one the plane type, the other the rotational type were used in this study. A TMJ model was made from Teflon for the purpose of evaluation by shifting the x-ray beam. The x-ray images were obtained by tilting the model from 0 to 10 degrees 2-degree increments. These x-ray images were processed for computer image analysis, and then the distance between condyle and the joint space was measured. To evaluate the influence of the shifted tomographic focal plane on image sharpness, the x-ray images from each setting were analyzed by MTF. To obtain the MTF, ''knife-edge'' made from Pb was used. The images were scanned with a microdensitometer at the central focal plane, and 0, 0.5, 1 mm away respectively. The density curves were analyzed by Fourier analysis and the MTF was calculated. The reproducibility of images became worse by shifting the x-ray beam. This tendency was similar for both tomograms. Object characteristics such as anterior and posterior portion of the joint space affected the deterioration of reproducibility of the tomography. The deviation of the tomographic focal plane also decreased the reproducibility of the x-ray images. The rotational type showed a better MTF, but it became seriously unfavorable with slight changes of the tomographic focal plane. Contrarily, the plane type showed a lower MTF, but the image was stable with shifting of the tomographic focal plane. (author)

  2. Reproducibility of the interpretation of pelvic x-ray 3 months after hysteroscopic sterilization with Essure.

    Science.gov (United States)

    Veersema, Sebastiaan; Mol, Ben W J; Brölmann, Hans A M

    2010-09-01

    To estimate the diagnostic accuracy and the interobserver reproducibility of pelvic x-rays in the diagnosis of successful bilateral sterilization with Essure after a 3-month follow-up period. Interobserver study. Outpatient department of obstetrics and gynecology in a Dutch teaching hospital. Patients with successful bilateral Essure placement. Hysteroscopic sterilization with Essure and pelvic x-ray and hysterosalpingography after a 3-month follow-up period. Six observers evaluations of 47 pelvic x-rays from 47 patients 3 months after a technical successful bilateral placement of microinserts to estimate the reliability of the sterilization. Diagnostic accuracy of pelvic x-ray per observer in detecting incorrectly positioned microinserts was expressed in terms of sensitivity and specificity, with hysterosalpingography as the reference strategy. Reproducibility of the interpretation of the pelvic x-ray was expressed as kappa-values. The sensitivity and specificity for x-rays read by gynecologists was 0.67 (95% confidence interval [CI], 0.29-0.96) and 0.79 (95% CI, 0.58-1.00) and for radiologists 1.0 and 0.5 (95% CI, 0.36-0.64). The interobserver agreement in reliability of pelvic x-ray of hysteroscopic sterilization assessment with Essure ranged from slight (kappa-value=0.09) for gynecologists to moderate (kappa-value=0.52) for radiologists. Test characteristics of pelvic x-ray as the imaging technique to assess the position of the Essure microinserts and tubal patency were poor, as was the reproducibility, particularly if gynecologists performed the evaluation. We do not recommend the use of pelvic x-ray for the assessment of the positioning of microinserts after hysteroscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  3. Peripheral nerve MRI: precision and reproducibility of T2*-derived measurements at 3.0-T. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto [University of Genoa, Institute of Anatomy, Department of Experimental Medicine, Genoa (Italy); Bignotti, Bianca; Martinoli, Carlo [University of Genoa, Radiology Department, Genoa, Genova (Italy); Tagliafico, Giulio [CNR-IMATI, Consiglio Nazionale delle Ricerche, Istituto di Matematica Applicata e Tecnologie Informatiche, Genova (Italy)

    2015-05-01

    To prospectively evaluate the precision and reproducibility of T2*-derived measurements of the peripheral nerves. The study was approved by the local ethics committee and written informed consent was obtained. Bilateral upper and lower limb MRI examination was performed in 40 healthy subjects on a 3.0-T scanner. MRI protocol included T1-turbo spin-echo, T2-turbo spin-echo with fat suppression, and multiecho gradient recalled echo. Measurements of T2* times on T2* maps at different anatomical levels were performed. Three authors measured independently and in different sessions at baseline and after 4 weeks. Non-parametric tests and Bland-Altman statistics were used. Minimum and maximum percentage variability were 10 % and 19 % for T2* (84-91 % of reproducibility). Maximum values of minimum detectable differences between limbs was 16 % (with 95 % CI: 2-37). Intra- and inter-observer agreement of the three radiologists for T2* was considered good. Evaluating the combined influence of the observer and of the repeated measurements the reproducibility was 87-98 %. T2* measurement of the peripheral nerves is precise and reproducible. The healthy contralateral side can be used as an internal control. Variations in T2* values up to 16 % have to be considered. (orig.)

  4. Reproducibility of retinal circulation measurements obtained using laser speckle flowgraphy-NAVI in patients with glaucoma

    Directory of Open Access Journals (Sweden)

    Nakamura M

    2011-08-01

    Full Text Available Naoko Aizawa, Yu Yokoyama, Naoki Chiba, Kazuko Omodaka, Masayuki Yasuda, Takaaki Otomo, Masahiko Nakamura, Nobuo Fuse, Toru NakazawaDepartment of Ophthalmology, Tohoku University Graduate School of Medicine Sendai, Miyagi, JapanBackground: Laser speckle flowgraphy (LSFG enables noninvasive quantification of the retinal circulation in glaucoma patients. In this study, we tested the intrasession reproducibility of LSFG-NAVI, a modified LSFG technique.Methods: Sixty-five eyes from 33 subjects (male (M:female (F = 17:16 with a mean age of 49.4 ± 11.2 years were examined in this study. Two parameters indicating reproducibility – the coefficient of variation (COV and the intraclass correlation coefficient (ICC – were analyzed three times on the same day that mean blur rate (MBR was measured using LSFG-NAVI. The sites analyzed were the retinal artery and vein, the optic disk, and the choroid. Following classification according to the Glaucoma Hemifield Test (GHT; SITA-Standard 30-2 program, the COV and ICC were examined in patients with (GHT+; 38 eyes, M:F = 20:18, average age 48.9 ± 12.8 years and without (GHT-; 27 eyes, M:F = 13:14, average age 50.1 ± 8.7 years abnormal glaucomatous visual fields.Results: For all subjects, the intrasession reproducibility of MBR in the optic disk (COV: 3.4 ± 2.0; ICC: 0.95 and choroid (COV: 4.7 ± 3.4; ICC: 0.98 was excellent. The reproducibility for the retinal vein (COV: 8.4 ± 5.6, ICC: 0.90 and retinal artery (COV: 10.9 ± 9.9, ICC: 0.9 was moderate. MBRs in the optic disk had good reproducibility in both the GHT+ group (COV: 3.8 ± 2.0; ICC: 0.97 and the GHT− group (COV: 2.9 ± 2.1; ICC: 0.95. Local assessment of the optic disk in normal or glaucoma patients showed that the COVs of the quadrant optic disk areas were best in the temporal area of MBR (3.4%, 4.2%, respectively.Conclusion: LSFG-NAVI showed favorable reproducibility in evaluation of retinal circulation of glaucoma patients, particularly in

  5. Novel Use of the Nintendo Wii Board for Measuring Isometric Lower Limb Strength: A Reproducible and Valid Method in Older Adults.

    Science.gov (United States)

    Gronbech Jorgensen, Martin; Andersen, Stig; Ryg, Jesper; Masud, Tahir

    2015-01-01

    Portable, low-cost, objective and reproducible assessment of muscle strength in the lower limbs is important as it allows clinicians to precisly track progression of patients undergoing rehabilitation. The Nintendo Wii Balance Board (WBB) is portable, inexpensive, durable, available worldwide, and may serve the above function. The purpose of the study was to evaluate (1) reproducibility and (2) concurrent validity of the WBB for measuring isometric muscle strength in the lower limb. A custom hardware and software was developed to utilize the WBB for assessment of isometric muscle strength. Thirty older adults (69.0 ± 4.2 years of age) were studied on two separate occasions on both the WBB and a stationary isometric dynamometer (SID). On each occasion, three recordings were obtained from each device. For the first recording, means and maximum values were used for further analysis. The test-retest reproducibility was examined using intraclass correlation coefficients (ICC), Standard Error of Measurement (SEM), and limits of agreement (LOA). Bland-Altman plots (BAP) and ICC's were used to explore concurrent validity. No systematic difference between test-retest was detected for the WBB. ICC within-device were between 0.90 and 0.96 and between-devices were from 0.80 to 0.84. SEM ranged for the WBB from 9.7 to 13.9%, and for the SID from 11.9 to 13.1%. LOA ranged for the WBB from 20.3 to 28.7% and for the SID from 24.2 to 26.6%. The BAP showed no relationship between the difference and the mean. A high relative and an acceptable absolute reproducibility combined with a good validity was found for the novel method using the WBB for measuring isometric lower limb strength in older adults. Further research using the WBB for assessing lower limb strength should be conducted in different study-populations.

  6. Novel Use of the Nintendo Wii Board for Measuring Isometric Lower Limb Strength: A Reproducible and Valid Method in Older Adults.

    Directory of Open Access Journals (Sweden)

    Martin Gronbech Jorgensen

    Full Text Available Portable, low-cost, objective and reproducible assessment of muscle strength in the lower limbs is important as it allows clinicians to precisly track progression of patients undergoing rehabilitation. The Nintendo Wii Balance Board (WBB is portable, inexpensive, durable, available worldwide, and may serve the above function.The purpose of the study was to evaluate (1 reproducibility and (2 concurrent validity of the WBB for measuring isometric muscle strength in the lower limb.A custom hardware and software was developed to utilize the WBB for assessment of isometric muscle strength. Thirty older adults (69.0 ± 4.2 years of age were studied on two separate occasions on both the WBB and a stationary isometric dynamometer (SID. On each occasion, three recordings were obtained from each device. For the first recording, means and maximum values were used for further analysis. The test-retest reproducibility was examined using intraclass correlation coefficients (ICC, Standard Error of Measurement (SEM, and limits of agreement (LOA. Bland-Altman plots (BAP and ICC's were used to explore concurrent validity.No systematic difference between test-retest was detected for the WBB. ICC within-device were between 0.90 and 0.96 and between-devices were from 0.80 to 0.84. SEM ranged for the WBB from 9.7 to 13.9%, and for the SID from 11.9 to 13.1%. LOA ranged for the WBB from 20.3 to 28.7% and for the SID from 24.2 to 26.6%. The BAP showed no relationship between the difference and the mean.A high relative and an acceptable absolute reproducibility combined with a good validity was found for the novel method using the WBB for measuring isometric lower limb strength in older adults. Further research using the WBB for assessing lower limb strength should be conducted in different study-populations.

  7. Reproducibility of 3.0 Tesla Magnetic Resonance Spectroscopy for Measuring Hepatic Fat Content

    NARCIS (Netherlands)

    van Werven, Jochem R.; Hoogduin, Johannes M.; Nederveen, Aart J.; van Vliet, Andre A.; Wajs, Ewa; Vandenberk, Petra; Stroes, Erik S. G.; Stoker, Jaap

    Purpose: To investigate reproducibility of proton magnetic resonance spectroscopy (H-1-MRS) to measure hepatic triglyceride content (HTGC). Materials and Methods: In 24 subjects, HTGC was evaluated using H-1-MRS at 3.0 Tesla. We studied "between-weeks" reproducibility and reproducibility of H-1-MRS

  8. Reproducibility of central lumbar vertebral BMD

    International Nuclear Information System (INIS)

    Chan, F.; Pocock, N.; Griffiths, M.; Majerovic, Y.; Freund, J.

    1997-01-01

    Full text: Lumbar vertebral bone mineral density (BMD) using dual X-ray absorptiometry (DXA) has generally been calculated from a region of interest which includes the entire vertebral body. Although this region excludes part of the transverse processes, it does include the outer cortical shell of the vertebra. Recent software has been devised to calculate BMD in a central vertebral region of interest which excludes the outer cortical envelope. Theoretically this area may be more sensitive to detecting osteoporosis which affects trabecular bone to a greater extent than cortical bone. Apart from the sensitivity of BMD estimation, the reproducibility of any measurement is important owing to the slow rate of change of bone mass. We have evaluated the reproducibility of this new vertebral region of interest in 23 women who had duplicate lumbar spine DXA scans performed on the same day. The patients were repositioned between each measurement. Central vertebral analysis was performed for L2-L4 and the reproducibility of area, bone mineral content (BMC) and BMD calculated as the coefficient of variation; these values were compared with those from conventional analysis. Thus we have shown that the reproducibility of the central BMD is comparable to the conventional analysis which is essential if this technique is to provide any additional clinical data. The reasons for the decrease in reproducibility of the area and hence BMC requires further investigation

  9. Reproducibility and intermethod reliability of a calcium food frequency questionnaire for use in Hispanic, non-Hispanic Black, and non-Hispanic White youth.

    Science.gov (United States)

    Ollberding, Nicholas J; Gilsanz, Vicente; Lappe, Joan M; Oberfield, Sharon E; Shepherd, John A; Winer, Karen K; Zemel, Babette S; Kalkwarf, Heidi J

    2015-04-01

    A dietary assessment instrument designed for use in a nationally representative pediatric population was required to examine associations between calcium intake and bone mineral accrual in a large, multicenter study. To determine the reproducibility and intermethod reliability of a youth calcium food frequency questionnaire (FFQ) in a multiracial/ethnic sample of children and adolescents. Reproducibility (n=69) and intermethod reliability (n=393) studies were conducted by administering repeat FFQs and three unannounced 24-hour dietary recalls to stratified random samples of individuals participating in the Bone Mineral Density in Childhood Study. Children and adolescents ages 5 to 21 years. Calcium intake estimated from the FFQ and 24-hour dietary recalls. Reproducibility was assessed by the intraclass correlation coefficient (ICC). Intermethod reliability was assessed by deattenuated Pearson correlations between the FFQ and 24-hour recalls. Attenuation factors and calibration corrected effect estimates for bone density were calculated to determine the potential influence of measurement error on associations with health outcomes. The ICC (0.61) for repeat administrations and deattenuated Pearson correlation between the FFQ and 24-hour recalls (r=0.60) for all subjects indicated reproducibility and intermethod reliability (Pearson r=0.50 to 0.74 across sex and age groups). Attenuation factors were ≤0.50 for all sex and age groups and lower for non-Hispanic blacks (λ=0.20) and Hispanics (λ=0.26) than for non-Hispanic whites (λ=0.42). The Bone Mineral Density in Childhood Study calcium FFQ appears to provide a useful tool for assessing calcium intake in children and adolescents drawn from multiracial/ethnic populations and/or spanning a wide age range. However, similar to other FFQs, attenuation factors were substantially <1, indicating the potential for appreciable measurement error bias. Calibration correction should be performed and racial/ethnic differences

  10. Reproducibility in cyclostratigraphy: initiating an intercomparison project

    Science.gov (United States)

    Sinnesael, Matthias; De Vleeschouwer, David; Zeeden, Christian; Claeys, Philippe

    2017-04-01

    The study of astronomical climate forcing and the application of cyclostratigraphy have experienced a spectacular growth over the last decades. In the field of cyclostratigraphy a broad range in methodological approaches exist. However, comparative study between the different approaches is lacking. Different cases demand different approaches, but with the growing importance of the field, questions arise about reproducibility, uncertainties and standardization of results. The radioisotopic dating community, in particular, has done far-reaching efforts to improve reproducibility and intercomparison of radioisotopic dates and their errors. To satisfy this need in cyclostratigraphy, we initiate a comparable framework for the community. The aims are to investigate and quantify reproducibility of, and uncertainties related to cyclostratigraphic studies and to provide a platform to discuss the merits and pitfalls of different methodologies, and their applicabilities. With this poster, we ask the feedback from the community on how to design this comparative framework in a useful, meaningful and productive manner. In parallel, we would like to discuss how reproducibility should be tested and what uncertainties should stand for in cyclostratigraphy. On the other hand, we intend to trigger interest for a cyclostratigraphic intercomparison project. This intercomparison project would imply the analysis of artificial and genuine geological records by individual researchers. All participants would be free to determine their method of choice. However, a handful of criterions will be required for an outcome to be comparable. The different results would be compared (e.g. during a workshop or a special session), and the lessons learned from the comparison could potentially be reported in a review paper. The aim of an intercomparison project is not to rank the different methods according to their merits, but to get insight into which specific methods are most suitable for which

  11. Assessment of macrophage migration inhibitory factor in humans: protocol for accurate and reproducible levels.

    Science.gov (United States)

    Sobierajski, Julia; Hendgen-Cotta, Ulrike B; Luedike, Peter; Stock, Pia; Rammos, Christos; Meyer, Christian; Kraemer, Sandra; Stoppe, Christian; Bernhagen, Jürgen; Kelm, Malte; Rassaf, Tienush

    2013-10-01

    The analytical validation of a possible biomarker is the first step in the long translational process from basic science to clinical routine. Although the chemokine-like cytokine macrophage migration inhibitory factor (MIF) has been investigated intensively in experimental approaches to various disease conditions, its transition into clinical research is just at the very beginning. Because of its presence in preformed storage pools, MIF is the first cytokine to be released under various stimulation conditions. In the first proof-of-concept studies, MIF levels correlated with the severity and outcome of various disease states. In a recent small study with acute coronary syndrome patients, elevation of MIF was described as a new factor for risk assessment. When these studies are compared, not only MIF levels in diseased patients differ, but also MIF levels in healthy control groups are inconsistent. Blood MIF concentrations in control groups vary between 0.56 and 95.6 ng/ml, corresponding to a 170-fold difference. MIF concentrations in blood were analyzed by ELISA. Other than the influence of this approach due to method-based variations, the impact of preanalytical processing on MIF concentrations is unclear and has not been systematically studied yet. Before large randomized studies are performed to determine the impact of circulating MIF on prognosis and outcome and before MIF is characterized as a diagnostic marker, an accurate protocol for the determination of reproducible MIF levels needs to be validated. In this study, the measurement of MIF in the blood of healthy volunteers was investigated focusing on the potential influence of critical preanalytical factors such as anticoagulants, storage conditions, freeze/thaw stability, hemolysis, and dilution. We show how to avoid pitfalls in the measurement of MIF and that MIF concentrations are highly susceptible to preanalytical factors. MIF serum concentrations are higher than plasma concentrations and show broader

  12. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  13. Standardization and interlaboratory reproducibility assessment of pulsed-field gel electrophoresis-generated fingerprints of Acinetobacter baumannii.

    Science.gov (United States)

    Seifert, Harald; Dolzani, Lucilla; Bressan, Raffaela; van der Reijden, Tanny; van Strijen, Beppie; Stefanik, Danuta; Heersma, Herre; Dijkshoorn, Lenie

    2005-09-01

    A standard procedure for pulsed-field gel electrophoresis (PFGE) of macrorestriction fragments of Acinetobacter baumannii was set up and validated for its interlaboratory reproducibility and its potential for use in the construction of an Internet-based database for international monitoring of epidemic strains. The PFGE fingerprints of strains were generated at three different laboratories with ApaI as the restriction enzyme and by a rigorously standardized procedure. The results were analyzed at the respective laboratories and also centrally at a national reference institute. In the first phase of the study, 20 A. baumannii strains, including 3 isolates each from three well-characterized hospital outbreaks and 11 sporadic strains, were distributed blindly to the participating laboratories. The local groupings of the isolates in each participating laboratory were identical and allowed the identification of the epidemiologically related isolates as belonging to three clusters and identified all unrelated strains as distinct. Central pattern analysis by using the band-based Dice coefficient and the unweighted pair group method with mathematical averaging as the clustering algorithm showed 95% matching of the outbreak strains processed at each local laboratory and 87% matching of the corresponding strains if they were processed at different laboratories. In the second phase of the study, 30 A. baumannii isolates representing 10 hospital outbreaks from different parts of Europe (3 isolates per outbreak) were blindly distributed to the three laboratories, so that each laboratory investigated 10 epidemiologically independent outbreak isolates. Central computer-assisted cluster analysis correctly identified the isolates according to their corresponding outbreak at an 87% clustering threshold. In conclusion, the standard procedure enabled us to generate PFGE fingerprints of epidemiologically related A. baumannii strains at different locations with sufficient

  14. The validity and reproducibility of food-frequency questionnaire–based total antioxidant capacity estimates in Swedish women

    Science.gov (United States)

    Total antioxidant capacity (TAC) provides an assessment of antioxidant activity and synergistic interactions of redox molecules in foods and plasma. We investigated the validity and reproducibility of food frequency questionnaire (FFQ)–based TAC estimates assessed by oxygen radical absorbance capaci...

  15. Intra- and interobserver reproducibility of vertebral endplate signal (modic) changes in the lumbar spine

    DEFF Research Database (Denmark)

    Jensen, Tue Secher; Sorensen, Joan Solgaard; Kjær, Per

    2007-01-01

    . PURPOSE: To assess the intra- and interobserver reliability of the "Nordic Modic classification" protocol. MATERIAL AND METHODS: MRI scans of 50 individuals representative of the general Danish population aged 40 were evaluated by two observers. Criteria for grading the changes were developed...... by the Nordic Modic Consensus Group. After consensus was established, all 50 MRI examinations were evaluated independently by each observer. Intraobserver reliability was assessed by re-evaluation of the 50 examinations by one of the observers. Kappa statistics were used to calculate agreement. RESULTS: Intra....... CONCLUSION: In this study, we found convincing reproducibility of a detailed evaluation protocol of vertebral endplate signal changes, the "Nordic Modic Classification." The authors recommend that the evaluation protocol should be used in future studies investigating vertebral endplate signal changes....

  16. Histopathologic reproducibility of thyroid disease in an epidemiologic study

    International Nuclear Information System (INIS)

    Ron, E.; Griffel, B.; Liban, E.; Modan, B.

    1986-01-01

    An investigation of the long-term effects of childhood scalp irradiation demonstrated a significantly increased risk of thyroid tumors in the irradiated population. Because of the complexity of thyroid cancer diagnosis, a histopathologic slide review of 59 of the 68 patients (irradiated and nonirradiated) with thyroid disease was undertaken. The review revealed 90% agreement (kappa = +0.85, P less than 0.01) between the original and review diagnosis. Four of 27 cases previously diagnosed as malignant were reclassified as benign, yielding a cancer misdiagnosis rate of 14.8%. All four of the misdiagnosed cancers were of follicular or mixed papillary-follicular type. As a result of the histologic review, the ratio of malignant to benign tumors decreased from 2.55 to 1.75. Since disagreement in diagnosis was similar in the irradiated and nonirradiated groups, the relative risk of radiation-associated neoplasms did not change substantially. The histopathologic review shows that although there were some problems in diagnostic reproducibility, they were not statistically significant and did not alter our previous conclusions regarding radiation exposure. However, a 15% reduction in the number of malignancies might affect epidemiologic studies with an external comparison as well as geographic or temporal comparisons

  17. Accuracy and reproducibility of tumor positioning during prolonged and multi-modality animal imaging studies

    International Nuclear Information System (INIS)

    Zhang Mutian; Huang Minming; Le, Carl; Zanzonico, Pat B; Ling, C Clifton; Koutcher, Jason A; Humm, John L; Claus, Filip; Kolbert, Katherine S; Martin, Kyle

    2008-01-01

    Dedicated small-animal imaging devices, e.g. positron emission tomography (PET), computed tomography (CT) and magnetic resonance imaging (MRI) scanners, are being increasingly used for translational molecular imaging studies. The objective of this work was to determine the positional accuracy and precision with which tumors in situ can be reliably and reproducibly imaged on dedicated small-animal imaging equipment. We designed, fabricated and tested a custom rodent cradle with a stereotactic template to facilitate registration among image sets. To quantify tumor motion during our small-animal imaging protocols, 'gold standard' multi-modality point markers were inserted into tumor masses on the hind limbs of rats. Three types of imaging examination were then performed with the animals continuously anesthetized and immobilized: (i) consecutive microPET and MR images of tumor xenografts in which the animals remained in the same scanner for 2 h duration, (ii) multi-modality imaging studies in which the animals were transported between distant imaging devices and (iii) serial microPET scans in which the animals were repositioned in the same scanner for subsequent images. Our results showed that the animal tumor moved by less than 0.2-0.3 mm over a continuous 2 h microPET or MR imaging session. The process of transporting the animal between instruments introduced additional errors of ∼0.2 mm. In serial animal imaging studies, the positioning reproducibility within ∼0.8 mm could be obtained.

  18. Repeatability and Reproducibility in Proteomic Identifications by Liquid Chromatography—Tandem Mass Spectrometry

    Science.gov (United States)

    Tabb, David L.; Vega-Montoto, Lorenzo; Rudnick, Paul A.; Variyath, Asokan Mulayath; Ham, Amy-Joan L.; Bunk, David M.; Kilpatrick, Lisa E.; Billheimer, Dean D.; Blackman, Ronald K.; Cardasis, Helene L.; Carr, Steven A.; Clauser, Karl R.; Jaffe, Jacob D.; Kowalski, Kevin A.; Neubert, Thomas A.; Regnier, Fred E.; Schilling, Birgit; Tegeler, Tony J.; Wang, Mu; Wang, Pei; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Fisher, Susan J.; Gibson, Bradford W.; Kinsinger, Christopher R.; Mesri, Mehdi; Rodriguez, Henry; Stein, Steven E.; Tempst, Paul; Paulovich, Amanda G.; Liebler, Daniel C.; Spiegelman, Cliff

    2009-01-01

    The complexity of proteomic instrumentation for LC-MS/MS introduces many possible sources of variability. Data-dependent sampling of peptides constitutes a stochastic element at the heart of discovery proteomics. Although this variation impacts the identification of peptides, proteomic identifications are far from completely random. In this study, we analyzed interlaboratory data sets from the NCI Clinical Proteomic Technology Assessment for Cancer to examine repeatability and reproducibility in peptide and protein identifications. Included data spanned 144 LC-MS/MS experiments on four Thermo LTQ and four Orbitrap instruments. Samples included yeast lysate, the NCI-20 defined dynamic range protein mix, and the Sigma UPS 1 defined equimolar protein mix. Some of our findings reinforced conventional wisdom, such as repeatability and reproducibility being higher for proteins than for peptides. Most lessons from the data, however, were more subtle. Orbitraps proved capable of higher repeatability and reproducibility, but aberrant performance occasionally erased these gains. Even the simplest protein digestions yielded more peptide ions than LC-MS/MS could identify during a single experiment. We observed that peptide lists from pairs of technical replicates overlapped by 35–60%, giving a range for peptide-level repeatability in these experiments. Sample complexity did not appear to affect peptide identification repeatability, even as numbers of identified spectra changed by an order of magnitude. Statistical analysis of protein spectral counts revealed greater stability across technical replicates for Orbitraps, making them superior to LTQ instruments for biomarker candidate discovery. The most repeatable peptides were those corresponding to conventional tryptic cleavage sites, those that produced intense MS signals, and those that resulted from proteins generating many distinct peptides. Reproducibility among different instruments of the same type lagged behind

  19. Imaging of striatal dopamine transporters in rat brain with single pinhole SPECT and co-aligned MRI is highly reproducible

    International Nuclear Information System (INIS)

    Booij, Jan; Bruin, Kora de; Win, Maartje M.L. de; Lavini, Cristina Mphil; Heeten, Gerard J. den; Habraken, Jan

    2003-01-01

    A recently developed pinhole high-resolution SPECT system was used to measure striatal to non-specific binding ratios in rats (n = 9), after injection of the dopamine transporter ligand 123 I-FP-CIT, and to assess its test/retest reproducibility. For co-alignment purposes, the rat brain was imaged on a 1.5 Tesla clinical MRI scanner using a specially developed surface coil. The SPECT images showed clear striatal uptake. On the MR images, cerebral and extra-cerebral structures could be easily delineated. The mean striatal to non-specific [ 123 I]FP-CIT binding ratios of the test/retest studies were 1.7 ± 0.2 and 1.6 ± 0.2, respectively. The test/retest variability was approximately 9%. We conclude that the assessment of striatal [ 123 I]FP-CIT binding ratios in rats is highly reproducible

  20. [Inter-laboratory reproducibility of pulsed-field electrophoresis for the study of 12 types of Pseudomonas aeruginosa].

    Science.gov (United States)

    Foissaud, V; Puyhardy, J M; Chapalain, J C; Salord, H; Depina, J J; Morillon, M; Nicolas, P; Perrier-Gros-Claude, J D

    1999-12-01

    The increasing hospital-to-hospital transmission of multiple drug-resistant bacteria is a major concern for bacteriology laboratories involved in nosocomial infection control. The interlaboratory reproducibility of pulsed-field gel electrophoresis (PFGE) for Pseudomonas aeruginosa typing was evaluated by asking four hospital laboratories (two in Lyon, one in Brest, and one in Marseille) to study 11 P. aeruginosa isolates, some of which were epidemiologically related, and the reference strain ATCC 27853. Two laboratories used the Genepath system, one the Chef DR II, system, and one the Chef Mapper system, Bio-Rad, restriction/Spe I. Profiles were read visually and by computerized comparison of restriction band molecular weights (Taxotron, software, PAD Grimont, Pasteur Institute, Paris, France). These two methods led to similar epidemiological conclusions. However, centralization of the data showed poor center-to-center reproducibility due to inadequate standardization of the procedure.

  1. Examination of reproducibility in microbiological degredation experiments

    DEFF Research Database (Denmark)

    Sommer, Helle Mølgaard; Spliid, Henrik; Holst, Helle

    1998-01-01

    Experimental data indicate that certain microbiological degradation experiments have a limited reproducibility. Nine identical batch experiments were carried out on 3 different days to examine reproducibility. A pure culture, isolated from soil, grew with toluene as the only carbon and energy...... source. Toluene was degraded under aerobic conditions at a constant temperature of 28 degreesC. The experiments were modelled by a Monod model - extended to meet the air/liquid system, and the parameter values were estimated using a statistical nonlinear estimation procedure. Model reduction analysis...... resulted in a simpler model without the biomass decay term. In order to test for model reduction and reproducibility of parameter estimates, a likelihood ratio test was employed. The limited reproducibility for these experiments implied that all 9 batch experiments could not be described by the same set...

  2. Validity and reproducibility of a food frequency questionnaire as a measure of recent dietary intake in young adults.

    Directory of Open Access Journals (Sweden)

    Lana Hebden

    Full Text Available This research assessed the relative validity and reproducibility of the Dietary Questionnaire for Epidemiological Studies (DQESV2 over one month in young adults, given the lack of concise and convenient instruments for assessing recent dietary intake in this population. Participants were recruited from a large Australian university (N = 102; 35% male; age 18-34 years; body mass index 16-37 kg/m(2. Five one-day weighed food records (WFR were administered over one month followed by the DQESV2. Estimates for nutrients (energy, protein, total fat, saturated fat, carbohydrate, sugars, dietary fibre, and alcohol and fruit and vegetable servings were compared between methods using correlation coefficients, 95% limits of agreement, and quintile classifications. One week later, a second DQESV2 was completed by n = 77 of the participants to assess reproducibility using intra-class correlations (ICC and weighted kappa. Comparing methods, all nutrients and fruit and vegetable servings showed significant positive correlations (P<0.05 except protein intake in males; over 60% of participants were within one quintile classification except total fat and dietary fibre intakes in males (55% and 56%, respectively; and differences in nutrient and food intakes between methods were all within +/-20% of the mean WFR values except alcohol intake in females. Between first and second administrations of the DQESV2 all ICC coefficients were positive (P<0.01 and weighted kappa coefficients ranged from 0.54 for fruit servings (including fruit juice in males to 0.91 for protein intake in females. Over a one month period, the DQESV2 demonstrated good reproducibility for the studied nutrients and for fruit and vegetable servings and provided a valid measure of the studied nutrients, except alcohol in females, and of fruit servings (including fruit juice in both genders, at the group level in this young adult population.

  3. The MARS for squat, countermovement, and standing long jump performance analyses: are measures reproducible?

    Science.gov (United States)

    Hébert-Losier, Kim; Beaven, C Martyn

    2014-07-01

    Jump tests are often used to assess the effect of interventions because their outcomes are reported valid indicators of functional performance. In this study, we examined the reproducibility of performance parameters from 3 common jump tests obtained using the commercially available Kistler Measurement, Analysis and Reporting Software (MARS). On 2 separate days, 32 men performed 3 squat jumps (SJs), 3 countermovement jumps (CMJs), and 3 standing long jumps (LJs) on a Kistler force-plate. On both days, the performance measures from the best jump of each series were extracted using the MARS. Changes in the mean scores, intraclass correlation coefficients (ICCs), and coefficients of variations (CVs) were computed to quantify the between-day reproducibility of each parameter. Moreover, the reproducibility quantifiers specific to the 3 separate jumps were compared using nonparametric tests. Overall, an acceptable between-day reproducibility (mean ± SD, ICC, and CV) of SJ (0.88 ± 0.06 and 7.1 ± 3.8%), CMJ (0.84 ± 0.17 and 5.9 ± 4.1%), and LJ (0.80 ± 0.13 and 8.1 ± 4.1%) measures was found using the MARS, except for parameters directly relating to the rate of force development (i.e., time to maximal force) and change in momentum during countermovement (i.e., negative force impulse) where reproducibility was lower. A greater proportion of the performance measures from the standing LJs had low ICCs and/or high CVs values most likely owing to the complex nature of the LJ test. Practitioners and researchers can use most of the jump test parameters from the MARS with confidence to quantify changes in the functional ability of individuals over time, except for those relating to the rate of force development or change in momentum during countermovement phases of jumps.

  4. Scapular dyskinesis in trapezius myalgia and intraexaminer reproducibility of clinical tests

    DEFF Research Database (Denmark)

    Juul-Kristensen, Birgit; Hilt, Kenneth; Enoch, Flemming

    2011-01-01

    dyskinesis, general health, and work ability, and 19 cases and 14 controls participated in the reproducibility study. Intraexaminer reproducibility was good to excellent for 6 of 10 clinical variables (Intraclass Correlation Coefficient [ICC] 0.76-0.91; kappa 0.84-1.00), and fair to good for four variables...

  5. Study of reproducibility of measurements with the spectrometer of Bonner multispheres

    International Nuclear Information System (INIS)

    Azevedo, G.A.; Pereira, W.W.; Patrao, K.C.S.; Fonseca, E.S.

    2013-01-01

    This work aims to study the metrological behavior of the Bonner Multisphere Spectrometer (BMS) of the LN / LNMRI / IRD - Laboratorio Metrologia de Neutrons / Laboratorio Nacional de Metrologia e Radiacao Ionizante / Instituto de Radioprotecao e Dosimetria, for measurements in repeatability and reproducibility conditions. Initially, a simulation was done by applying the Monte Carlo method, using the MCNP code and respecting the ISO 8529-1 (2001), using the sources of Californium ( 252 Cf), Americium-Beryllium ( 241 AmBe) and californium in heavy water (Cf + D 2 O), all located at a distance of 100 cm from the neutron detector ( 6 Li (Eu) - crystal scintillator). In this program, the counting of neutrons that are captured by the detector was made. The source is located in the center of a sphere of radius 300 cm. Analyzes the impact of these neutrons in a point of the sphere wall, which in this case acted as a neutron detector and from there, it is estimated the number of neutrons that collide in the whole sphere. The purpose is to obtain the neutron count for different energy bands in a solid field of neutrons, since they have a spectrum ranging from a low to a high energy that can also vary within a particular environment. Wishes to obtain new fields with different sources and moderators materials to be used as new reference fields. Measurements are being conducted for these fields, with the aim of analyzing the variability conditions of the measurement (repeatability and reproducibility) in LEN - Laboratorio de Espectrometria de Neutrons of the LN/LMNRI/IRD. Thus, the spectrometer will be used to improve both the knowledge of the spectrum as the standard of neutrons of the lab, proving that a spectrometry is essential for correct measurement

  6. Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents

    Directory of Open Access Journals (Sweden)

    Mehmet Kola

    2014-01-01

    Full Text Available Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ. Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC. Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2 and reproducibility (ICC, 0.916-0.999 were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2 and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all. Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.

  7. Reproducibility Between Brain Uptake Ratio Using Anatomic Standardization and Patlak-Plot Methods.

    Science.gov (United States)

    Shibutani, Takayuki; Onoguchi, Masahisa; Noguchi, Atsushi; Yamada, Tomoki; Tsuchihashi, Hiroko; Nakajima, Tadashi; Kinuya, Seigo

    2015-12-01

    The Patlak-plot and conventional methods of determining brain uptake ratio (BUR) have some problems with reproducibility. We formulated a method of determining BUR using anatomic standardization (BUR-AS) in a statistical parametric mapping algorithm to improve reproducibility. The objective of this study was to demonstrate the inter- and intraoperator reproducibility of mean cerebral blood flow as determined using BUR-AS in comparison to the conventional-BUR (BUR-C) and Patlak-plot methods. The images of 30 patients who underwent brain perfusion SPECT were retrospectively used in this study. The images were reconstructed using ordered-subset expectation maximization and processed using an automatic quantitative analysis for cerebral blood flow of ECD tool. The mean SPECT count was calculated from axial basal ganglia slices of the normal side (slices 31-40) drawn using a 3-dimensional stereotactic region-of-interest template after anatomic standardization. The mean cerebral blood flow was calculated from the mean SPECT count. Reproducibility was evaluated using coefficient of variation and Bland-Altman plotting. For both inter- and intraoperator reproducibility, the BUR-AS method had the lowest coefficient of variation and smallest error range about the Bland-Altman plot. Mean CBF obtained using the BUR-AS method had the highest reproducibility. Compared with the Patlak-plot and BUR-C methods, the BUR-AS method provides greater inter- and intraoperator reproducibility of cerebral blood flow measurement. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  8. Intercenter reproducibility of binary typing for Staphylococcus aureus

    NARCIS (Netherlands)

    van Leeuwen, Willem B.; Snoeijers, Sandor; van der Werken-Libregts, Christel; Tuip, Anita; van der Zee, Anneke; Egberink, Diane; de Proost, Monique; Bik, Elisabeth; Lunter, Bjorn; Kluytmans, Jan; Gits, Etty; van Duyn, Inge; Heck, Max; van der Zwaluw, Kim; Wannet, Wim; Noordhoek, Gerda T.; Mulder, Sije; Renders, Nicole; Boers, Miranda; Zaat, Sebastiaan; van der Riet, Daniëlle; Kooistra, Mirjam; Talens, Adriaan; Dijkshoorn, Lenie; van der Reyden, Tanny; Veenendaal, Dick; Bakker, Nancy; Cookson, Barry; Lynch, Alisson; Witte, Wolfgang; Cuny, Christa; Blanc, Dominique; Vernez, Isabelle; Hryniewicz, Waleria; Fiett, Janusz; Struelens, Marc; Deplano, Ariane; Landegent, Jim; Verbrugh, Henri A.; van Belkum, Alex

    2002-01-01

    The reproducibility of the binary typing (BT) protocol developed for epidemiological typing of Staphylococcus aureus was analyzed in a biphasic multicenter study. In a Dutch multicenter pilot study, 10 genetically unique isolates of methicillin-resistant S. aureus (MRSA) were characterized by the BT

  9. Guidelines for Reproducibly Building and Simulating Systems Biology Models.

    Science.gov (United States)

    Medley, J Kyle; Goldberg, Arthur P; Karr, Jonathan R

    2016-10-01

    Reproducibility is the cornerstone of the scientific method. However, currently, many systems biology models cannot easily be reproduced. This paper presents methods that address this problem. We analyzed the recent Mycoplasma genitalium whole-cell (WC) model to determine the requirements for reproducible modeling. We determined that reproducible modeling requires both repeatable model building and repeatable simulation. New standards and simulation software tools are needed to enhance and verify the reproducibility of modeling. New standards are needed to explicitly document every data source and assumption, and new deterministic parallel simulation tools are needed to quickly simulate large, complex models. We anticipate that these new standards and software will enable researchers to reproducibly build and simulate more complex models, including WC models.

  10. Assessing risk of bias in studies that evaluate health care interventions

    DEFF Research Database (Denmark)

    Page, Matthew J.; Boutron, Isabelle; Hansen, Camilla

    2018-01-01

    Methods to assess risk of bias in a way that is reliable, reproducible and transparent to readers, have evolved over time. Viswanathan et al. recently provided updated recommendations for assessing risk of bias in systematic reviews of health care interventions. We comment on their recommendations...

  11. Reproducibility of Ultrasound and Magnetic Resonance Imaging Measurements of Tendon Size

    International Nuclear Information System (INIS)

    Brushoej, C.; Henriksen, B.M.; Albrecht-Beste, E.; Hoelmich, P.; Larsen, K.; Bachmann Nielsen, M.

    2006-01-01

    Purpose: To investigate the intra- and inter-tester reproducibility of measurements of the Achilles tendon, tibialis anterior tendon, and the tibialis posterior tendon in football players using ultrasound (US) and magnetic resonance imaging (MRI). Material and Methods: Eleven asymptomatic football players were examined. Using a standardized US scanning protocol, the tendons were examined by two observers with US for thickness, width, and cross-sectional area. One observer conducted the procedure twice. The subjects also underwent an MRI examination, and the assessment of tendon size was conducted twice by two observers. Results: The best reproducibility judged by coefficient of variation (CV) and 95% confidence interval was determined for the Achilles tendon on both US and MRI. The variability of US on measurements on the tibialis anterior and tibialis posterior tendons was less than that when using MRI. In 12 out of 18 measurements, there were systematic differences between observers as judged by one-sided F-test. Conclusion: The reproducibility of the three tendons was limited. Precaution should be taken when looking for minor quantitative changes, i.e., training-induced hypertrophy, and when doing so, the Achilles tendon should be used

  12. Reproducibility of ad libitum energy intake with the use of a computerized vending machine system123

    Science.gov (United States)

    Votruba, Susanne B; Franks, Paul W; Krakoff, Jonathan; Salbe, Arline D

    2010-01-01

    Background: Accurate assessment of energy intake is difficult but critical for the evaluation of eating behavior and intervention effects. Consequently, methods to assess ad libitum energy intake under controlled conditions have been developed. Objective: Our objective was to evaluate the reproducibility of ad libitum energy intake with the use of a computerized vending machine system. Design: Twelve individuals (mean ± SD: 36 ± 8 y old; 41 ± 8% body fat) consumed a weight-maintaining diet for 3 d; subsequently, they self-selected all food with the use of a computerized vending machine system for an additional 3 d. Mean daily energy intake was calculated from the actual weight of foods consumed and expressed as a percentage of weight-maintenance energy needs (%WMEN). Subjects repeated the study multiple times during 2 y. The within-person reproducibility of energy intake was determined through the calculation of the intraclass correlation coefficients (ICCs) between visits. Results: Daily energy intake for all subjects was 5020 ± 1753 kcal during visit 1 and 4855 ± 1615 kcal during visit 2. There were no significant associations between energy intake and body weight, body mass index, or percentage body fat while subjects used the vending machines, which indicates that intake was not driven by body size or need. Despite overconsumption (%WMEN = 181 ± 57%), the reproducibility of intake between visits, whether expressed as daily energy intake (ICC = 0.90), %WMEN (ICC = 0.86), weight of food consumed (ICC = 0.87), or fat intake (g/d; ICC = 0.87), was highly significant (P < 0.0001). Conclusion: Although ad libitum energy intake exceeded %WMEN, the within-person reliability of this intake across multiple visits was high, which makes this a reproducible method for the measurement of ad libitum intake in subjects who reside in a research unit. This trial was registered at clinicaltrials.gov as NCT00342732. PMID:19923376

  13. Validation of Interobserver Agreement in Lung Cancer Assessment: Hematoxylin-Eosin Diagnostic Reproducibility for Non–Small Cell Lung Cancer

    Science.gov (United States)

    Grilley-Olson, Juneko E.; Hayes, D. Neil; Moore, Dominic T.; Leslie, Kevin O.; Wilkerson, Matthew D.; Qaqish, Bahjat F.; Hayward, Michele C.; Cabanski, Christopher R.; Yin, Xiaoying; Socinski, Mark A.; Stinchcombe, Thomas E.; Thorne, Leigh B.; Allen, Timothy Craig; Banks, Peter M.; Beasley, Mary B.; Borczuk, Alain C.; Cagle, Philip T.; Christensen, Rebecca; Colby, Thomas V.; Deblois, Georgean G.; Elmberger, Göran; Graziano, Paolo; Hart, Craig F.; Jones, Kirk D.; Maia, Diane M.; Miller, C. Ryan; Nance, Keith V.; Travis, William D.; Funkhouser, William K.

    2018-01-01

    Context Precise subtype diagnosis of non–small cell lung carcinoma is increasingly relevant, based on the availability of subtype-specific therapies, such as bevacizumab and pemetrexed, and based on the subtype-specific prevalence of activating epidermal growth factor receptor mutations. Objectives To establish a baseline measure of inter-observer reproducibility for non–small cell lung carcinoma diagnoses with hematoxylin-eosin for the current 2004 World Health Organization classification, to estimate interobserver reproducibility for the therapeutically relevant squamous/nonsquamous subsets, and to examine characteristics that improve interobserver reproducibility. Design Primary, resected lung cancer specimens were converted to digital (virtual) slides. Based on a single hematoxylin-eosin virtual slide, pathologists were asked to assign a diagnosis using the 2004 World Health Organization classification. Kappa statistics were calculated for each pathologist-pair for each slide and were summarized by classification scheme, pulmonary pathology expertise, diagnostic confidence, and neoplastic grade. Results The 12 pulmonary pathology experts and the 12 community pathologists each independently diagnosed 48 to 96 single hematoxylin-eosin digital slides derived from 96 cases of non–small cell lung carcinoma resection. Overall agreement improved with simplification from the comprehensive 44 World Health Organization diagnoses (κ = 0.25) to their 10 major header subtypes (κ = 0.48) and improved again with simplification into the therapeutically relevant squamous/nonsquamous dichotomy (κ = 0.55). Multivariate analysis showed that higher diagnostic agreement was associated with better differentiation, better slide quality, higher diagnostic confidence, similar years of pathology experience, and pulmonary pathology expertise. Conclusions These data define the baseline diagnostic agreement for hematoxylin-eosin diagnosis of non–small cell lung carcinoma

  14. Reproducibility of MRI-Determined Proton Density Fat Fraction Across Two Different MR Scanner Platforms

    Science.gov (United States)

    Kang, Geraldine H.; Cruite, Irene; Shiehmorteza, Masoud; Wolfson, Tanya; Gamst, Anthony C.; Hamilton, Gavin; Bydder, Mark; Middleton, Michael S.; Sirlin, Claude B.

    2016-01-01

    Purpose To evaluate magnetic resonance imaging (MRI)-determined proton density fat fraction (PDFF) reproducibility across two MR scanner platforms and, using MR spectroscopy (MRS)-determined PDFF as reference standard, to confirm MRI-determined PDFF estimation accuracy. Materials and Methods This prospective, cross-sectional, crossover, observational pilot study was approved by an Institutional Review Board. Twenty-one subjects gave written informed consent and underwent liver MRI and MRS at both 1.5T (Siemens Symphony scanner) and 3T (GE Signa Excite HD scanner). MRI-determined PDFF was estimated using an axial 2D spoiled gradient-recalled echo sequence with low flip-angle to minimize T1 bias and six echo-times to permit correction of T2* and fat-water signal interference effects. MRS-determined PDFF was estimated using a stimulated-echo acquisition mode sequence with long repetition time to minimize T1 bias and five echo times to permit T2 correction. Interscanner reproducibility of MRI determined PDFF was assessed by correlation analysis; accuracy was assessed separately at each field strength by linear regression analysis using MRS-determined PDFF as reference standard. Results 1.5T and 3T MRI-determined PDFF estimates were highly correlated (r = 0.992). MRI-determined PDFF estimates were accurate at both 1.5T (regression slope/intercept = 0.958/−0.48) and 3T (slope/intercept = 1.020/0.925) against the MRS-determined PDFF reference. Conclusion MRI-determined PDFF estimation is reproducible and, using MRS-determined PDFF as reference standard, accurate across two MR scanner platforms at 1.5T and 3T. PMID:21769986

  15. Repeatability, Reproducibility and Standardisation of a Laser Doppler Imaging Technique for the Evaluation of Normal Mouse Hindlimb Perfusion

    Directory of Open Access Journals (Sweden)

    Arturo Brunetti

    2012-12-01

    Full Text Available Background. Preclinical perfusion studies are useful for the improvement of diagnosis and therapy in dermatologic, cardiovascular and rheumatic human diseases. The Laser Doppler Perfusion Imaging (LDPI technique has been used to evaluate superficial alterations of the skin microcirculation in surgically induced murine hindlimb ischemia. We assessed the reproducibility and the accuracy of LDPI acquisitions and identified several critical factors that could affect LDPI measurements in mice. Methods. Twenty mice were analysed. Statistical standardisation and a repeatability and reproducibility analysis were performed on mouse perfusion signals with respect to differences in body temperature, the presence or absence of hair, the type of anaesthesia used for LDPI measurements and the position of the mouse body. Results. We found excellent correlations among measurements made by the same operator (i.e., repeatability under the same experimental conditions and by two different operators (i.e., reproducibility. A Bland-Altman analysis showed the absence of bias in repeatability (p = 0.29 or reproducibility (p = 0.89. The limits of agreement for repeatability were –0.357 and –0.033, and for reproducibility, they were –0.270 and 0.238. Significant differences in perfusion values were observed in different experimental groups. Conclusions. Different experimental conditions must be considered as a starting point for the evaluation of new drugs and strategic therapies.

  16. Validity and reproducibility of a short food frequency questionnaire among patients with chronic kidney disease.

    Science.gov (United States)

    Affret, Aurélie; Wagner, Sandra; El Fatouhi, Douae; Dow, Courtney; Correia, Emmanuelle; Niravong, Maryvonne; Clavel-Chapelon, Françoise; De Chefdebien, Julie; Fouque, Denis; Stengel, Bénédicte; Boutron-Ruault, Marie-Christine; Fagherazzi, Guy

    2017-09-15

    A balanced diet is essential to slowing the progression of chronic kidney disease (CKD) and managing the symptoms. Currently, no tool is available to easily and quickly assess energy and macronutrient intake in patients with non end-stage CKD. We aimed to develop and evaluate the validity and reproducibility of a new short 49-item food frequency questionnaire (SFFQ) adapted to patients with CKD. The CKD-REIN study is a prospective cohort that enrolled 3033 patients with moderate or advanced CKD from a national sample of nephrology clinics. A sub-sample of 201 patients completed the SFFQ twice, at a one-year interval and were included in the reproducibility study. During this interval, 127 patients also completed six 24-h recalls and were included in the validity study. Main nutrient and dietary intakes were computed. Validity was evaluated by calculating crude, energy-adjusted and de-attenuated correlation coefficients (CC) between FFQ and the mean of the 24-h recall results. Bland-Altman plots were performed and cross-classification into quintiles of consumption of each nutrient and food group was computed. Reproducibility between the two SFFQs was evaluated by intraclass CC (ICC). Regarding validity, CC ranged from 0.05 to 0.79 (unadjusted CC, median: 0.40) and 0.10 to 0.59 (de-attenuated CC, median: 0.35) for food group and nutrient intakes, respectively. Five of the most important nutrients of interest in CKD, i.e. protein, calcium, phosphorus, potassium, and sodium had de-attenuated CC of 0.46, 0.43, 0.39, 0.32, and 0.12, respectively. The median of classification into the same or adjacent quintiles was 68% and 65% for food and nutrient intakes, respectively, and ranged from 63% to 69% for the five nutrients mentioned before. Bland-Altman plots showed good agreement across the range of intakes. ICC ranged from 0.18 to 0.66 (median: 0.46). The CKD-REIN SFFQ showed acceptable validity and reproducibility in a sample of patients with CKD, notably for CKD

  17. Reproducing {sup 137}Cs vertical migration in Spanish soils - Reproducing {sup 137}Cs and {sup 90}Sr vertical migration in Spanish mainland

    Energy Technology Data Exchange (ETDEWEB)

    Olondo, C.; Legarda, F.; Herranz, M.; Idoeta, R. [The University of the Basque Country - UPV/EHU, Nuclear Engineering and Fluid Mechanics Dept. Faculty of Engineering, Alda. Urquijo 48013, Bilbao (Spain)

    2014-07-01

    As a result of caesium's and strontium's activity migration study developed in Spanish mainland soils, there has been obtained convective - diffusive migration equation that will reproduce adequately the movement that an activity deposit would follow in this land. Taking into account the dependence on rain that apparent convection velocity shows, it has been defined a new migration parameter that depends only on soil's properties. By means of a least square method and fitting the migration equation to experimental activity profiles, the values showed by the migration parameters in the studied soils, characteristics of that area, have been obtained. After that, there have been obtained the mean values of these parameters for each defined group that, depending on soil's texture, have been observed in the study performed about the movement of both radionuclides in soils and to whom these soils belong. Using these mean values and obtained equation, it has been properly reproduce those vertical activity profiles that were experimentally determined. In order to validate these values, a new sampling programme is carrying out in the north of Spain and, with obtained new sampling points' information, is going to verify if, indeed, obtained mean values also reproduce these new sampling points' activity vertical profile. (authors)

  18. Between-visit reproducibility of inter-arm systolic blood pressure differences in treated hypertensive patients: the coconet study.

    Science.gov (United States)

    Kim, Jang Young; Kim, Eung Ju; Namgung, June; Cho, Byung-Ryul; Nam, Chang-Wook; Kim, Young-Kwon; Park, Jeong Bae

    2017-05-01

    Inter-arm systolic blood pressure (BP) differences (sIADs) have recently been recognized as a risk factor for cardiovascular mortality. However, sIAD reproducibility remains unresolved from a controlled trial perspective. We evaluated the between-visit reproducibility of sIADs in hypertensive patients. We examined 1875 hypertensive participants aged 20 years and older (mean age: 62.3 years, 45.4% female) from nine primary clinics and 27 secondary and tertiary hospitals. The BPs in both arms were automatically and simultaneously measured in triplicate with a cuff-oscillometric BP device. BP measurements were obtained at baseline and at 3-month follow-up time points. Increased sIAD was defined as an absolute difference of ⩾10 mm Hg in the average systolic BPs between the left and right arms. The overall mean sIAD was 4.33±4.17 mm Hg. The prevalences of increased sIAD at baseline and at the 3-month measurements were 7.6% and 7.1%, respectively. The intraclass correlation coefficient for the between-visit sIADs was 0.304 (95% confidence interval (CI) 0.262-0.344). The κ-value between the baseline and follow-up increased sIADs was 0.165 (95% CI 0.096-0.234). The percentage of patients who exhibited an increased sIAD at 3 months compared with the initially increased sIAD at baseline was 21.8%. The reproducibility of sIAD determination between baseline and the 3-month follow-up measurements lacked agreement in the hypertensive patients. Further studies should identify the relevant variables and characteristics of this poor reproducibility (CRIS number; KCT0001235).

  19. Additive Manufacturing: Reproducibility of Metallic Parts

    Directory of Open Access Journals (Sweden)

    Konda Gokuldoss Prashanth

    2017-02-01

    Full Text Available The present study deals with the properties of five different metals/alloys (Al-12Si, Cu-10Sn and 316L—face centered cubic structure, CoCrMo and commercially pure Ti (CP-Ti—hexagonal closed packed structure fabricated by selective laser melting. The room temperature tensile properties of Al-12Si samples show good consistency in results within the experimental errors. Similar reproducible results were observed for sliding wear and corrosion experiments. The other metal/alloy systems also show repeatable tensile properties, with the tensile curves overlapping until the yield point. The curves may then follow the same path or show a marginal deviation (~10 MPa until they reach the ultimate tensile strength and a negligible difference in ductility levels (of ~0.3% is observed between the samples. The results show that selective laser melting is a reliable fabrication method to produce metallic materials with consistent and reproducible properties.

  20. Reliability and reproducibility analysis of the Cobb angle and assessing sagittal plane by computer-assisted and manual measurement tools.

    Science.gov (United States)

    Wu, Weifei; Liang, Jie; Du, Yuanli; Tan, Xiaoyi; Xiang, Xuanping; Wang, Wanhong; Ru, Neng; Le, Jinbo

    2014-02-06

    Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproducible measurements. Sixty-eight standard standing posteroanterior whole-spine radiographs were reviewed. Three examiners carried out the measurements independently under the settings of manual measurement on X-ray radiographies and SurgimapSpine software on the computer. Parameters measured included pelvic incidence, sacral slope, pelvic tilt, Lumbar lordosis (LL), thoracic kyphosis, and coronal Cobb angle. SPSS 16.0 software was used for statistical analyses. The means, standard deviations, intraclass and interclass correlation coefficient (ICC), and 95% confidence intervals (CI) were calculated. There was no notable difference between the two tools (P = 0.21) for the coronal Cobb angle. In the sagittal plane parameters, the ICC of intraobserver reliability for the manual measures varied from 0.65 (T2-T5 angle) to 0.95 (LL angle). Further, for SurgimapSpine tool, the ICC ranged from 0.75 to 0.98. No significant difference in intraobserver reliability was found between the two measurements (P > 0.05). As for the interobserver reliability, measurements with SurgimapSpine tool had better ICC (0.71 to 0.98 vs 0.59 to 0.96) and Pearson's coefficient (0.76 to 0.99 vs 0.60 to 0.97). The reliability of SurgimapSpine measures was significantly higher in all parameters except for the coronal Cobb angle where the difference was not significant (P > 0.05). Although the differences between the two methods are very small, the results of this study indicate that the SurgimapSpine measurement is an equivalent measuring tool to the traditional manual in coronal Cobb angle, but is advantageous in spino

  1. Novel use of the Nintendo Wii board as a measure of reaction time: a study of reproducibility in older and younger adults.

    Science.gov (United States)

    Jorgensen, Martin Gronbech; Paramanathan, Sentha; Ryg, Jesper; Masud, Tahir; Andersen, Stig

    2015-07-10

    Reaction time (RT) has been associated with falls in older adults, but is not routinely tested in clinical practice. A simple, portable, inexpensive and reliable method for measuring RT is desirable for clinical settings. We therefore developed a custom software, which utilizes the portable and low-cost standard Nintendo Wii board (NWB) to record RT. The aims in the study were to (1) explore if the test could differentiate old and young adults, and (2) to study learning effects between test-sessions, and (3) to examine reproducibility. A young (n = 25, age 20-35 years, mean BMI of 22.6) and an old (n = 25, age ≥65 years, mean BMI of 26.3) study-population were enrolled in this within- and between-day reproducibility study. A standard NWB was used along with the custom software to obtain RT from participants in milliseconds. A mixed effect model was initially used to explore systematic differences associated with age, and test-session. Reproducibility was then expressed by Intraclass Correlation Coefficients (ICC), Coefficient of Variance (CV), and Typical Error (TE). The RT tests was able to differentiate the old group from the young group in both the upper extremity test (p Nintendo wii board showed good reproducibility, no or little systematic learning effects across test-sessions, and could differentiate between young and older adults in both upper and lower extremity tests.

  2. Reproducibility over a 1-month period of (1)H-MR spectroscopic imaging NAA/Cr ratios in clinically stable multiple sclerosis patients

    NARCIS (Netherlands)

    Mostert, J. P.; Blaauw, Y.; Koch, M. W.; Kuiper, A. J.; Hoogduin, J. M.; De Keyser, J.

    N-acetylaspartate/creatine (NAA/Cr) ratios, assessed with proton magnetic resonance spectroscopy, are increasingly used as a surrogate marker for axonal dysfunction and degeneration in multiple sclerosis (MS). The purpose of this study was to test short-time reproducibility of NAA/Cr ratios in

  3. Does systematic variation improve the reproducibility of animal experiments?

    NARCIS (Netherlands)

    Jonker, R.M.; Guenther, A.; Engqvist, L.; Schmoll, T.

    2013-01-01

    Reproducibility of results is a fundamental tenet of science. In this journal, Richter et al.1 tested whether systematic variation in experimental conditions (heterogenization) affects the reproducibility of results. Comparing this approach with the current standard of ensuring reproducibility

  4. Reproducibility and predictive value of scoring stromal tumour infiltrating lymphocytes in triple-negative breast cancer: a multi-institutional study.

    Science.gov (United States)

    O'Loughlin, Mark; Andreu, Xavier; Bianchi, Simonetta; Chemielik, Ewa; Cordoba, Alicia; Cserni, Gábor; Figueiredo, Paulo; Floris, Giuseppe; Foschini, Maria P; Heikkilä, Päivi; Kulka, Janina; Liepniece-Karele, Inta; Regitnig, Peter; Reiner, Angelika; Ryska, Ales; Sapino, Anna; Shalaby, Aliaa; Stovgaard, Elisabeth Specht; Quinn, Cecily; Walsh, Elaine M; Zolota, Vicky; Glynn, Sharon A; Callagy, Grace

    2018-05-17

    Several studies have demonstrated a prognostic role for stromal tumour infiltrating lymphocytes (sTILs) in triple-negative breast cancer (TNBC). The reproducibility of scoring sTILs is variable with potentially excellent concordance being achievable using a software tool. We examined agreement between breast pathologists across Europe scoring sTILs on H&E-stained sections without software, an approach that is easily applied in clinical practice. The association between sTILs and response to anthracycline-taxane NACT was also examined. Pathologists from the European Working Group for Breast Screening Pathology scored sTILs in 84 slides from 75 TNBCs using the immune-oncology biomarker working group guidance in two circulations. There were 16 participants in the first and 19 in the second circulation. Moderate agreement was achieved for absolute sTILs scores (intraclass correlation coefficient (ICC) = 0.683, 95% CI 0.601-0.767, p-value value value values (Spearman ρ = 0.727); fair for sTILs ≥ 25% (κ = 0.53) and for LPBC (κ = 0.49), but poor for sTILs as 10% increments (κ = 0.24). Increasing sTILs was significantly associated with an increased likelihood of a pathological complete response (pCR) on multivariable analysis. Increasing sTILs in TNBCs improves the likelihood of a pCR. However, inter-observer agreement is such that H&E-based assessment is not sufficiently reproducible for clinical application. Other methodologies should be explored, but may be at the cost of ease of application.

  5. European LeukemiaNet study on the reproducibility of bone marrow features in masked polycythemia vera and differentiation from essential thrombocythemia.

    Science.gov (United States)

    Kvasnicka, Hans Michael; Orazi, Attilio; Thiele, Juergen; Barosi, Giovanni; Bueso-Ramos, Carlos E; Vannucchi, Alessandro M; Hasserjian, Robert P; Kiladjian, Jean-Jacques; Gianelli, Umberto; Silver, Richard; Mughal, Tariq I; Barbui, Tiziano

    2017-10-01

    The purpose of the study was to assess consensus and interobserver agreement among an international panel of six hematopathologists regarding characterization and reproducibility of bone marrow (BM) histologic features used to diagnose early stage myeloproliferative neoplasms, in particular differentiation of so-called masked/prodromal polycythemia vera (mPV) from JAK2-mutated essential thrombocythemia (ET). The six members of the hematopathology panel evaluated 98 BM specimens independently and in a blinded fashion without knowledge of clinical data. The specimens included 48 cases of mPV according to the originally published hemoglobin threshold values for this entity (male: 16.0-18.4 g/dL, female: 15.0-16.4 g/dL), 31 cases with overt PV according to the updated 2016 WHO criteria, and 19 control cases. The latter group included cases of JAK2-mutated ET, primary myelofibrosis, myelodysplastic syndrome, and various reactive conditions. Inter-rater agreement between the panelists was very high (overall agreement 92.6%, kappa 0.812), particularly with respect to separating mPV from ET. Virtually all cases of mPV were correctly classified as PV according to their BM morphology. In conclusion, a central blinded review of histology slides by six hematopathologists demonstrated that highly reproducible specific histological pattern characterize PV and confirmed the notion that there are no significant differences between mPV and overt PV in relation to BM morphology. © 2017 Wiley Periodicals, Inc.

  6. Appearance Constrained Semi-Automatic Segmentation from DCE-MRI is Reproducible and Feasible for Breast Cancer Radiomics: A Feasibility Study.

    Science.gov (United States)

    Veeraraghavan, Harini; Dashevsky, Brittany Z; Onishi, Natsuko; Sadinski, Meredith; Morris, Elizabeth; Deasy, Joseph O; Sutton, Elizabeth J

    2018-03-19

    We present a segmentation approach that combines GrowCut (GC) with cancer-specific multi-parametric Gaussian Mixture Model (GCGMM) to produce accurate and reproducible segmentations. We evaluated GCGMM using a retrospectively collected 75 invasive ductal carcinoma with ERPR+ HER2- (n = 15), triple negative (TN) (n = 9), and ER-HER2+ (n = 57) cancers with variable presentation (mass and non-mass enhancement) and background parenchymal enhancement (mild and marked). Expert delineated manual contours were used to assess the segmentation performance using Dice coefficient (DSC), mean surface distance (mSD), Hausdorff distance, and volume ratio (VR). GCGMM segmentations were significantly more accurate than GrowCut (GC) and fuzzy c-means clustering (FCM). GCGMM's segmentations and the texture features computed from those segmentations were the most reproducible compared with manual delineations and other analyzed segmentation methods. Finally, random forest (RF) classifier trained with leave-one-out cross-validation using features extracted from GCGMM segmentation resulted in the best accuracy for ER-HER2+ vs. ERPR+/TN (GCGMM 0.95, expert 0.95, GC 0.90, FCM 0.92) and for ERPR + HER2- vs. TN (GCGMM 0.92, expert 0.91, GC 0.77, FCM 0.83).

  7. Effective Form of Reproducing the Total Financial Potential of Ukraine

    Directory of Open Access Journals (Sweden)

    Portna Oksana V.

    2015-03-01

    Full Text Available Development of scientific principles of reproducing the total financial potential of the country and its effective form is an urgent problem both in theoretical and practical aspects of the study, the solution of which is intended to ensure the active mobilization and effective use of the total financial potential of Ukraine, and as a result — its expanded reproduction as well, which would contribute to realization of the internal capacities for stabilization of the national economy. The purpose of the article is disclosing the essence of the effective form of reproducing the total financial potential of the country, analyzing the results of reproducing the total financial potential of Ukraine. It has been proved that the basis for the effective form of reproducing the total financial potential of the country is the volume and flow of resources, which are associated with the «real» economy, affect the dynamics of GDP and define it, i.e. resource and process forms of reproducing the total financial potential of Ukraine (which precede the effective one. The analysis of reproducing the total financial potential of Ukraine has shown that in the analyzed period there was an increase in the financial possibilities of the country, but steady dynamics of reduction of the total financial potential was observed. If we consider the amount of resources involved in production, creating a net value added and GDP, it occurs on a restricted basis. Growth of the total financial potential of Ukraine is connected only with extensive quantitative factors rather than intensive qualitative changes.

  8. Reproducibility of corticospinal diffusion tensor tractography in normal subjects and hemiparetic stroke patients

    International Nuclear Information System (INIS)

    Lin, Chao-Chun; Tsai, Miao-Yu; Lo, Yu-Chien; Liu, Yi-Jui; Tsai, Po-Pang; Wu, Chiao-Ying; Lin, Chia-Wei; Shen, Wu-Chung; Chung, Hsiao-Wen

    2013-01-01

    Purpose: The reproducibility of corticospinal diffusion tensor tractography (DTT) for a guideline is important before longitudinal monitoring of the therapy effects in stroke patients. This study aimed to establish the reproducibility of corticospinal DTT indices in healthy subjects and chronic hemiparetic stroke patients. Materials and methods: Written informed consents were obtained from 10 healthy subjects (mean age 25.8 ± 6.8 years), who underwent two scans in one session plus the third scan one week later, and from 15 patients (mean age 47.5 ± 9.1 years, 6–60 months after the onset of stroke, NIHSS scores between 9 and 20) who were scanned thrice on separate days within one month. Diffusion-tensor imaging was performed at 3 T with 25 diffusion directions. Corticospinal tracts were reconstructed using fiber assignment by continuous tracking without and with motion/eddy-current corrections. Intra- and inter-rater as well as intra- and inter-session variations of the DTT derived indices (fiber number, apparent diffusion coefficient (ADC), and fractional anisotropy (FA)) were assessed. Results: Intra-session and inter-session coefficients of variations (CVs) are small for FA (1.13–2.09%) and ADC (0.45–1.64%), but much larger for fiber number (8.05–22.4%). Inter-session CVs in the stroke side of patients (22.4%) are higher than those in the normal sides (18.0%) and in the normal subjects (14.7%). Motion/eddy-current correction improved inter-session reproducibility only for the fiber number of the infarcted corticospinal tract (CV reduced from 22.4% to 14.1%). Conclusion: The fiber number derived from corticospinal DTT shows substantially lower precision than ADC and FA, with infarcted tracts showing lower reproducibility than the healthy tissues

  9. SU-D-207B-01: Radiomics Feature Reproducibility From Repeat CT Scans of Patients with Rectal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hu, P; Wang, J; Zhong, H; Zhou, Z; Shen, L; Hu, W; Zhang, Z [Fudan University Shanghai Cancer Center, Shanghai, Shanghai (China)

    2016-06-15

    Purpose: To evaluate the reproducibility of radiomics features by repeating computed tomographic (CT) scans in rectal cancer. To choose stable radiomics features for rectal cancer. Methods: 40 rectal cancer patients were enrolled in this study, each of whom underwent two CT scans within average 8.7 days (5 days to 17 days), before any treatment was delivered. The rectal gross tumor volume (GTV) was distinguished and segmented by an experienced oncologist in both CTs. Totally, more than 2000 radiomics features were defined in this study, which were divided into four groups (I: GLCM, II: GLRLM III: Wavelet GLCM and IV: Wavelet GLRLM). For each group, five types of features were extracted (Max slice: features from the largest slice of target images, Max value: features from all slices of target images and choose the maximum value, Min value: minimum value of features for all slices, Average value: average value of features for all slices, Matrix sum: all slices of target images translate into GLCM and GLRLM matrices and superpose all matrices, then extract features from the superposed matrix). Meanwhile a LOG (Laplace of Gauss) filter with different parameters was applied to these images. Concordance correlation coefficients (CCC) and inter-class correlation coefficients (ICC) were calculated to assess the reproducibility. Results: 403 radiomics features were extracted from each type of patients’ medical images. Features of average type are the most reproducible. Different filters have little effect for radiomics features. For the average type features, 253 out of 403 features (62.8%) showed high reproducibility (ICC≥0.8), 133 out of 403 features (33.0%) showed medium reproducibility (0.8≥ICC≥0.5) and 17 out of 403 features (4.2%) showed low reproducibility (ICC≥0.5). Conclusion: The average type radiomics features are the most stable features in rectal cancer. Further analysis of these features of rectal cancer can be warranted for treatment monitoring and

  10. Reproducibility of contrast-enhanced transrectal ultrasound of the prostate

    NARCIS (Netherlands)

    Sedelaar, J. P.; Goossen, T. E.; Wijkstra, H.; de la Rosette, J. J.

    2001-01-01

    Transrectal three-dimensional (3-D) contrast-enhanced power Doppler ultrasound (US) is a novel technique for studying possible prostate malignancy. Before studies can be performed to investigate the clinical validity of the technique, reproducibility of the contrast US studies must be proven.

  11. Repeatability and reproducibility of intracellular molar concentration assessed by synchrotron-based x-ray fluorescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Merolle, L., E-mail: lucia.merolle@elettra.eu; Gianoncelli, A. [Elettra - Sincrotrone Trieste, 34149 Basovizza, Trieste (Italy); Malucelli, E., E-mail: emil.malucelli@unibo.it; Cappadone, C.; Farruggia, G.; Sargenti, A.; Procopio, A. [Department of Pharmacy and Biotechnology, University of Bologna, Bologna 40127 (Italy); Fratini, M. [Museo Storico della Fisica e Centro Studi e Ricerche Enrico Fermi, Piazza del Viminale 1, 00184 Roma Italy (Italy); Department of Science, Roma Tre University, Via della Vasca Navale 84, I-00146 Rome (Italy); Notargiacomo, A. [Institute for Photonics and Nanotechnology, Consiglio Nazionale delle Richerche, 00156 Rome (Italy); Lombardo, M. [Department of Chemistry “G. Ciamician”, University of Bologna, Bologna 40126 (Italy); Lagomarsino, S. [Institute of Chemical-Physical Processes, Sapienza University of Rome, 00185 Rome (Italy); National Institute of Biostructures and Biosystems, 00136 Rome (Italy); Iotti, S. [Department of Pharmacy and Biotechnology, University of Bologna, Bologna 40127 (Italy); National Institute of Biostructures and Biosystems, 00136 Rome (Italy)

    2016-01-28

    Elemental analysis of biological sample can give information about content and distribution of elements essential for human life or trace elements whose absence is the cause of abnormal biological function or development. However, biological systems contain an ensemble of cells with heterogeneous chemistry and elemental content; therefore, accurate characterization of samples with high cellular heterogeneity may only be achieved by analyzing single cells. Powerful methods in molecular biology are abundant, among them X-Ray microscopy based on synchrotron light source has gaining increasing attention thanks to its extremely sensitivity. However, reproducibility and repeatability of these measurements is one of the major obstacles in achieving a statistical significance in single cells population analysis. In this study, we compared the elemental content of human colon adenocarcinoma cells obtained by three distinct accesses to synchrotron radiation light.

  12. Does an eye-hand coordination test have added value as part of talent identification in table tennis? A validity and reproducibility study.

    Directory of Open Access Journals (Sweden)

    Irene R Faber

    Full Text Available This study investigated the added value, i.e. discriminative and concurrent validity and reproducibility, of an eye-hand coordination test relevant to table tennis as part of talent identification. Forty-three table tennis players (7-12 years from national (n = 13, regional (n = 11 and local training centres (n = 19 participated. During the eye-hand coordination test, children needed to throw a ball against a vertical positioned table tennis table with one hand and to catch the ball correctly with the other hand as frequently as possible in 30 seconds. Four different test versions were assessed varying the distance to the table (1 or 2 meter and using a tennis or table tennis ball. 'Within session' reproducibility was estimated for the two attempts of the initial tests and ten youngsters were retested after 4 weeks to estimate 'between sessions' reproducibility. Validity analyses using age as covariate showed that players from the national and regional centres scored significantly higher than players from the local centre in all test versions (p<0.05. The tests at 1 meter demonstrated better discriminative ability than those at 2 meter. While all tests but one had a positive significant association with competition outcome, which were corrected for age influences, the version with a table tennis ball at 1 meter showed the highest association (r = 0.54; p = 0.001. Differences between the first and second attempts were comparable for all test versions (between -8 and +7 repetitions with ICC's ranging from 0.72 to 0.87. The smallest differences were found for the test with a table tennis ball at 1 meter (between -3 and +3 repetitions. Best test version as part of talent identification appears to be the version with a table tennis ball at 1 meter regarding the psychometric characteristics evaluated. Longitudinal studies are necessary to evaluate the predictive value of this test.

  13. Learning Reproducibility with a Yearly Networking Contest

    KAUST Repository

    Canini, Marco

    2017-08-10

    Better reproducibility of networking research results is currently a major goal that the academic community is striving towards. This position paper makes the case that improving the extent and pervasiveness of reproducible research can be greatly fostered by organizing a yearly international contest. We argue that holding a contest undertaken by a plurality of students will have benefits that are two-fold. First, it will promote hands-on learning of skills that are helpful in producing artifacts at the replicable-research level. Second, it will advance the best practices regarding environments, testbeds, and tools that will aid the tasks of reproducibility evaluation committees by and large.

  14. Thou Shalt Be Reproducible! A Technology Perspective

    Directory of Open Access Journals (Sweden)

    Patrick Mair

    2016-07-01

    Full Text Available This article elaborates on reproducibility in psychology from a technological viewpoint. Modernopen source computational environments are shown and explained that foster reproducibilitythroughout the whole research life cycle, and to which emerging psychology researchers shouldbe sensitized, are shown and explained. First, data archiving platforms that make datasets publiclyavailable are presented. Second, R is advocated as the data-analytic lingua franca in psychologyfor achieving reproducible statistical analysis. Third, dynamic report generation environments forwriting reproducible manuscripts that integrate text, data analysis, and statistical outputs such asfigures and tables in a single document are described. Supplementary materials are provided inorder to get the reader started with these technologies.

  15. NetBenchmark: a bioconductor package for reproducible benchmarks of gene regulatory network inference.

    Science.gov (United States)

    Bellot, Pau; Olsen, Catharina; Salembier, Philippe; Oliveras-Vergés, Albert; Meyer, Patrick E

    2015-09-29

    In the last decade, a great number of methods for reconstructing gene regulatory networks from expression data have been proposed. However, very few tools and datasets allow to evaluate accurately and reproducibly those methods. Hence, we propose here a new tool, able to perform a systematic, yet fully reproducible, evaluation of transcriptional network inference methods. Our open-source and freely available Bioconductor package aggregates a large set of tools to assess the robustness of network inference algorithms against different simulators, topologies, sample sizes and noise intensities. The benchmarking framework that uses various datasets highlights the specialization of some methods toward network types and data. As a result, it is possible to identify the techniques that have broad overall performances.

  16. Translation, cultural adaptation and reproducibility of the Cochin Hand Functional Scale questionnaire for Brazil

    Directory of Open Access Journals (Sweden)

    Aline Chiari

    2011-01-01

    Full Text Available OBJECTIVE: To translate, to perform a cultural adaptation of and to test the reproducibility of the Cochin Hand Functional Scale questionnaire for Brazil. METHODS: First, the Cochin Hand Functional Scale questionnaire was translated into Portuguese and was then back-translated into French. These translations were reviewed by a committee to establish a Brazilian version of the questionnaire to be tested. The validity and reproducibility of the Cochin Hand Functional Scale questionnaire was evaluated. Patients of both sexes, who were aged 18 to 60 years and presented with rheumatoid arthritis affecting their hands, were interviewed. The patients were initially interviewed by two observers and were later interviewed by a single rater. First, the Visual Analogue Scale for hand pain, the Arm, Shoulder and Hand Disability questionnaire and the Health Assessment Questionnaire were administered. The third administration of the Cochin Hand Functional Scale was performed fifteen days after the first administration. Ninety patients were assessed in the present study. RESULTS: Two questions were modified as a result of the assessment of cultural equivalence. The Cronbach's alpha value for this assessment was 0.93. The intraclass intraobserver and interobserver correlation coefficients were 0.76 and 0.96, respectively. The Spearman's coefficient indicated that there was a low level of correlation between the Cochin Hand Functional Scale and the Visual Analogue Scale for pain (0.46 and that there was a moderate level of correlation of the Cochin Scale with the Health Assessment Questionnaire (0.66 and with the Disability of the Arm, Shoulder and Hand questionnaire (0.63. The average administration time for the Cochin Scale was three minutes. CONCLUSION: The Brazilian version of the Cochin Hand Functional Scale was successfully translated and adapted, and this version exhibited good internal consistency, reliability and construct validity.

  17. Reproducible research in palaeomagnetism

    Science.gov (United States)

    Lurcock, Pontus; Florindo, Fabio

    2015-04-01

    The reproducibility of research findings is attracting increasing attention across all scientific disciplines. In palaeomagnetism as elsewhere, computer-based analysis techniques are becoming more commonplace, complex, and diverse. Analyses can often be difficult to reproduce from scratch, both for the original researchers and for others seeking to build on the work. We present a palaeomagnetic plotting and analysis program designed to make reproducibility easier. Part of the problem is the divide between interactive and scripted (batch) analysis programs. An interactive desktop program with a graphical interface is a powerful tool for exploring data and iteratively refining analyses, but usually cannot operate without human interaction. This makes it impossible to re-run an analysis automatically, or to integrate it into a larger automated scientific workflow - for example, a script to generate figures and tables for a paper. In some cases the parameters of the analysis process itself are not saved explicitly, making it hard to repeat or improve the analysis even with human interaction. Conversely, non-interactive batch tools can be controlled by pre-written scripts and configuration files, allowing an analysis to be 'replayed' automatically from the raw data. However, this advantage comes at the expense of exploratory capability: iteratively improving an analysis entails a time-consuming cycle of editing scripts, running them, and viewing the output. Batch tools also tend to require more computer expertise from their users. PuffinPlot is a palaeomagnetic plotting and analysis program which aims to bridge this gap. First released in 2012, it offers both an interactive, user-friendly desktop interface and a batch scripting interface, both making use of the same core library of palaeomagnetic functions. We present new improvements to the program that help to integrate the interactive and batch approaches, allowing an analysis to be interactively explored and refined

  18. Reproducibility of Automated Voice Range Profiles, a Systematic Literature Review

    DEFF Research Database (Denmark)

    Printz, Trine; Rosenberg, Tine; Godballe, Christian

    2018-01-01

    literature on test-retest accuracy of the automated voice range profile assessment. Study design: Systematic review. Data sources: PubMed, Scopus, Cochrane Library, ComDisDome, Embase, and CINAHL (EBSCO). Methods: We conducted a systematic literature search of six databases from 1983 to 2016. The following......Objective: Reliable voice range profiles are of great importance when measuring effects and side effects from surgery affecting voice capacity. Automated recording systems are increasingly used, but the reproducibility of results is uncertain. Our objective was to identify and review the existing...... keywords were used: phonetogram, voice range profile, and acoustic voice analysis. Inclusion criteria were automated recording procedure, healthy voices, and no intervention between test and retest. Test-retest values concerning fundamental frequency and voice intensity were reviewed. Results: Of 483...

  19. Reproducibility of gene expression across generations of Affymetrix microarrays

    Directory of Open Access Journals (Sweden)

    Haslett Judith N

    2003-06-01

    Full Text Available Abstract Background The development of large-scale gene expression profiling technologies is rapidly changing the norms of biological investigation. But the rapid pace of change itself presents challenges. Commercial microarrays are regularly modified to incorporate new genes and improved target sequences. Although the ability to compare datasets across generations is crucial for any long-term research project, to date no means to allow such comparisons have been developed. In this study the reproducibility of gene expression levels across two generations of Affymetrix GeneChips® (HuGeneFL and HG-U95A was measured. Results Correlation coefficients were computed for gene expression values across chip generations based on different measures of similarity. Comparing the absolute calls assigned to the individual probe sets across the generations found them to be largely unchanged. Conclusion We show that experimental replicates are highly reproducible, but that reproducibility across generations depends on the degree of similarity of the probe sets and the expression level of the corresponding transcript.

  20. Reproducibility of the Portuguese version of the PEDro Scale

    Directory of Open Access Journals (Sweden)

    Silvia Regina Shiwa

    2011-10-01

    Full Text Available The objective of this study was to test the inter-rater reproducibility of the Portuguese version of the PEDro Scale. Seven physiotherapists rated the methodological quality of 50 reports of randomized controlled trials written in Portuguese indexed on the PEDro database. Each report was also rated using the English version of the PEDro Scale. Reproducibility was evaluated by comparing two separate ratings of reports written in Portuguese and comparing the Portuguese PEDro score with the English version of the scale. Kappa coefficients ranged from 0.53 to 1.00 for individual item and an intraclass correlation coefficient (ICC of 0.82 for the total PEDro score was observed. The standard error of the measurement of the scale was 0.58. The Portuguese version of the scale was comparable with the English version, with an ICC of 0.78. The inter-rater reproducibility of the Brazilian Portuguese PEDro Scale is adequate and similar to the original English version.

  1. Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions

    NARCIS (Netherlands)

    Wiranto, Matthew G.; Engelbrecht, W. Petrie; Nolthenius, Heleen E. Tutein; van der Meer, W. Joerd; Ren, Yijin

    INTRODUCTION: Digital 3-dimensional models are widely used for orthodontic diagnosis. The aim of this study was to assess the validity, reliability, and reproducibility of digital models obtained from the Lava Chairside Oral scanner (3M ESPE, Seefeld, Germany) and cone-beam computed tomography scans

  2. On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.

    Science.gov (United States)

    Chen, Kevin T; Izquierdo-Garcia, David; Poynton, Clare B; Chonde, Daniel B; Catana, Ciprian

    2017-03-01

    To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners. Continuous-valued linear attenuation coefficient maps ("μ-maps") were generated by combining atlases that provided the prior probability of voxel positions belonging to a certain tissue class (air, soft tissue, or bone) and an MR intensity-based likelihood classifier to produce posterior probability maps of tissue classes. These probabilities were used as weights to generate the μ-maps. The accuracy of this probabilistic atlas-based continuous-valued μ-map ("PAC-map") generation method was assessed by calculating the voxel-wise absolute relative change (RC) between the MR-based and scaled CT-based attenuation-corrected PET images. To assess reproducibility, we performed pair-wise comparisons of the RC values obtained from the PET images reconstructed using the μ-maps generated from the data acquired at three time points. The proposed method produced continuous-valued μ-maps that qualitatively reflected the variable anatomy in patients with brain tumor and agreed well with the scaled CT-based μ-maps. The absolute RC comparing the resulting PET volumes was 1.76 ± 2.33 %, quantitatively demonstrating that the method is accurate. Additionally, we also showed that the method is highly reproducible, the mean RC value for the PET images reconstructed using the μ-maps obtained at the three visits being 0.65 ± 0.95 %. Accurate and highly reproducible continuous-valued head μ-maps can be generated from MR data using a probabilistic atlas-based approach.

  3. On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Kevin T. [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Massachusetts Institute of Technology, Division of Health Sciences and Technology, Cambridge, MA (United States); Izquierdo-Garcia, David; Catana, Ciprian [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Poynton, Clare B. [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Massachusetts General Hospital, Department of Psychiatry, Boston, MA (United States); University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Chonde, Daniel B. [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Harvard University, Program in Biophysics, Cambridge, MA (United States)

    2017-03-15

    To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners. Continuous-valued linear attenuation coefficient maps (''μ-maps'') were generated by combining atlases that provided the prior probability of voxel positions belonging to a certain tissue class (air, soft tissue, or bone) and an MR intensity-based likelihood classifier to produce posterior probability maps of tissue classes. These probabilities were used as weights to generate the μ-maps. The accuracy of this probabilistic atlas-based continuous-valued μ-map (''PAC-map'') generation method was assessed by calculating the voxel-wise absolute relative change (RC) between the MR-based and scaled CT-based attenuation-corrected PET images. To assess reproducibility, we performed pair-wise comparisons of the RC values obtained from the PET images reconstructed using the μ-maps generated from the data acquired at three time points. The proposed method produced continuous-valued μ-maps that qualitatively reflected the variable anatomy in patients with brain tumor and agreed well with the scaled CT-based μ-maps. The absolute RC comparing the resulting PET volumes was 1.76 ± 2.33 %, quantitatively demonstrating that the method is accurate. Additionally, we also showed that the method is highly reproducible, the mean RC value for the PET images reconstructed using the μ-maps obtained at the three visits being 0.65 ± 0.95 %. Accurate and highly reproducible continuous-valued head μ-maps can be generated from MR data using a probabilistic atlas-based approach. (orig.)

  4. Reproducibility of heart rate variability parameters measured in healthy subjects at rest and after a postural change maneuver

    Directory of Open Access Journals (Sweden)

    E.M. Dantas

    2010-10-01

    Full Text Available Heart rate variability (HRV provides important information about cardiac autonomic modulation. Since it is a noninvasive and inexpensive method, HRV has been used to evaluate several parameters of cardiovascular health. However, the internal reproducibility of this method has been challenged in some studies. Our aim was to determine the intra-individual reproducibility of HRV parameters in short-term recordings obtained in supine and orthostatic positions. Electrocardiographic (ECG recordings were obtained from 30 healthy subjects (20-49 years, 14 men using a digital apparatus (sampling ratio = 250 Hz. ECG was recorded for 10 min in the supine position and for 10 min in the orthostatic position. The procedure was repeated 2-3 h later. Time and frequency domain analyses were performed. Frequency domain included low (LF, 0.04-0.15 Hz and high frequency (HF, 0.15-0.4 Hz bands. Power spectral analysis was performed by the autoregressive method and model order was set at 16. Intra-subject agreement was assessed by linear regression analysis, test of difference in variances and limits of agreement. Most HRV measures (pNN50, RMSSD, LF, HF, and LF/HF ratio were reproducible independent of body position. Better correlation indexes (r > 0.6 were obtained in the orthostatic position. Bland-Altman plots revealed that most values were inside the agreement limits, indicating concordance between measures. Only SDNN and NNv in the supine position were not reproducible. Our results showed reproducibility of HRV parameters when recorded in the same individual with a short time between two exams. The increased sympathetic activity occurring in the orthostatic position probably facilitates reproducibility of the HRV indexes.

  5. Evaluation of multichannel reproduced sound

    DEFF Research Database (Denmark)

    Choisel, Sylvain; Wickelmaier, Florian Maria

    2007-01-01

    A study was conducted with the goal of quantifying auditory attributes which underlie listener preference for multichannel reproduced sound. Short musical excerpts were presented in mono, stereo and several multichannel formats to a panel of forty selected listeners. Scaling of auditory attributes......, as well as overall preference, was based on consistency tests of binary paired-comparison judgments and on modeling the choice frequencies using probabilistic choice models. As a result, the preferences of non-expert listeners could be measured reliably at a ratio scale level. Principal components derived...

  6. SU-F-T-644: Reproducibility of Target Position Using Moderate Voluntary Breath- Hold During Liver Stereotactic Ablative Radiotherapy

    International Nuclear Information System (INIS)

    Cui, G; Trakul, N; Chang, E; Shiu, A

    2016-01-01

    Purpose: To evaluate the reproducibility of target position using moderate voluntary breath-hold during liver stereotactic ablative radiotherapy (SABR). Methods: Two patients who underwent liver SABR on a Varian TrueBeam STx linac were used for this study. Fiducial markers were placed in and around the target in the liver as surrogates for the target position and motion. GTVs were contoured by assessing tumor extent on contrast enhanced CT. The PTV was created from the GTV by adding 2 mm margins to account for the residual motion during breath-holds. A portable biofeedback system was used to facilitate the breath-hold to a reproducible position. The Varian RPM system was used for gating the linac. Proceeding each treatment, orthogonal kV pairs were taken, and alignment to nearby bony anatomy was performed. Then the breath-hold CBCT was acquired to align the fiducial markers. On-line fluoroscopy was used to fine-tune the breath-hold gating thresholds to correlate with the positions of the fiducial markers. The inter-fraction reproducibility of the target was evaluated by the offsets of the daily breath-hold CBCTs from the paired kV matches as a direct measure of the target position relative to the bony anatomy. The intra-fraction reproducibility of the target position was assessed by the gated window of the RPM marker block for each fraction. Results: The absolute mean offsets between the CBCT and paired kV matches in the vertical, longitudinal, and lateral directions were 0.06 cm, 0.10 cm, and 0.06 cm for patient 1, and 0.37 cm, 0.62 cm, and 0.09 cm for patient 2. The gated window of the RPM marker block for the breath-hold for each fraction was within 0.63 ± 0.16 cm and 0.59 ± 0.12 cm for patients 1 and 2, respectively. Conclusion: Moderate voluntary breath-hold showed good inter- and intra-fraction reproducibility of target position during liver SABR.

  7. SU-F-T-644: Reproducibility of Target Position Using Moderate Voluntary Breath- Hold During Liver Stereotactic Ablative Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Cui, G; Trakul, N; Chang, E; Shiu, A [University Southern California, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To evaluate the reproducibility of target position using moderate voluntary breath-hold during liver stereotactic ablative radiotherapy (SABR). Methods: Two patients who underwent liver SABR on a Varian TrueBeam STx linac were used for this study. Fiducial markers were placed in and around the target in the liver as surrogates for the target position and motion. GTVs were contoured by assessing tumor extent on contrast enhanced CT. The PTV was created from the GTV by adding 2 mm margins to account for the residual motion during breath-holds. A portable biofeedback system was used to facilitate the breath-hold to a reproducible position. The Varian RPM system was used for gating the linac. Proceeding each treatment, orthogonal kV pairs were taken, and alignment to nearby bony anatomy was performed. Then the breath-hold CBCT was acquired to align the fiducial markers. On-line fluoroscopy was used to fine-tune the breath-hold gating thresholds to correlate with the positions of the fiducial markers. The inter-fraction reproducibility of the target was evaluated by the offsets of the daily breath-hold CBCTs from the paired kV matches as a direct measure of the target position relative to the bony anatomy. The intra-fraction reproducibility of the target position was assessed by the gated window of the RPM marker block for each fraction. Results: The absolute mean offsets between the CBCT and paired kV matches in the vertical, longitudinal, and lateral directions were 0.06 cm, 0.10 cm, and 0.06 cm for patient 1, and 0.37 cm, 0.62 cm, and 0.09 cm for patient 2. The gated window of the RPM marker block for the breath-hold for each fraction was within 0.63 ± 0.16 cm and 0.59 ± 0.12 cm for patients 1 and 2, respectively. Conclusion: Moderate voluntary breath-hold showed good inter- and intra-fraction reproducibility of target position during liver SABR.

  8. Preserve specimens for reproducibility

    Czech Academy of Sciences Publication Activity Database

    Krell, F.-T.; Klimeš, Petr; Rocha, L. A.; Fikáček, M.; Miller, S. E.

    2016-01-01

    Roč. 539, č. 7628 (2016), s. 168 ISSN 0028-0836 Institutional support: RVO:60077344 Keywords : reproducibility * specimen * biodiversity Subject RIV: EH - Ecology, Behaviour Impact factor: 40.137, year: 2016 http://www.nature.com/nature/journal/v539/n7628/full/539168b.html

  9. Undefined cellulase formulations hinder scientific reproducibility.

    Science.gov (United States)

    Himmel, Michael E; Abbas, Charles A; Baker, John O; Bayer, Edward A; Bomble, Yannick J; Brunecky, Roman; Chen, Xiaowen; Felby, Claus; Jeoh, Tina; Kumar, Rajeev; McCleary, Barry V; Pletschke, Brett I; Tucker, Melvin P; Wyman, Charles E; Decker, Stephen R

    2017-01-01

    In the shadow of a burgeoning biomass-to-fuels industry, biological conversion of lignocellulose to fermentable sugars in a cost-effective manner is key to the success of second-generation and advanced biofuel production. For the effective comparison of one cellulase preparation to another, cellulase assays are typically carried out with one or more engineered cellulase formulations or natural exoproteomes of known performance serving as positive controls. When these formulations have unknown composition, as is the case with several widely used commercial products, it becomes impossible to compare or reproduce work done today to work done in the future, where, for example, such preparations may not be available. Therefore, being a critical tenet of science publishing, experimental reproducibility is endangered by the continued use of these undisclosed products. We propose the introduction of standard procedures and materials to produce specific and reproducible cellulase formulations. These formulations are to serve as yardsticks to measure improvements and performance of new cellulase formulations.

  10. Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging

    NARCIS (Netherlands)

    Papavassiliu, T.; Kuhl, H.P.; Schroder, M.; Suselbeck, T.; Bondarenko, O.; Bohm, C.K.; van de Beek, A.; Hofman, M.M.; van Rossum, A.C.

    2005-01-01

    PURPOSE: To prospectively assess the effect of including or excluding endocardial trabeculae in left ventricular (LV) measurements and the reproducibility of these measurements at cine cardiovascular magnetic resonance (MR) imaging with true fast imaging with steady-state precession (FISP).

  11. High-resolution 3D coronary vessel wall imaging with near 100% respiratory efficiency using epicardial fat tracking: reproducibility and comparison with standard methods.

    Science.gov (United States)

    Scott, Andrew D; Keegan, Jennifer; Firmin, David N

    2011-01-01

    To quantitatively assess the performance and reproducibility of 3D spiral coronary artery wall imaging with beat-to-beat respiratory-motion-correction (B2B-RMC) compared to navigator gated 2D spiral and turbo-spin-echo (TSE) acquisitions. High-resolution (0.7 × 0.7 mm) cross-sectional right coronary wall acquisitions were performed in 10 subjects using four techniques (B2B-RMC 3D spiral with alternate (2RR) and single (1RR) R-wave gating, navigator-gated 2D spiral (2RR) and navigator-gated 2D TSE (2RR)) on two occasions. Wall thickness measurements were compared with repeated measures analysis of variance (ANOVA). Reproducibility was assessed with the intraclass correlation coefficient (ICC). In all, 91% (73/80) of acquisitions were successful (failures: four TSE, two 3D spiral (1RR) and one 3D spiral (2RR)). Respiratory efficiency of the B2B-RMC was less variable and substantially higher than for navigator gating (99.6 ± 1.2% vs. 39.0 ± 7.5%, P B2B-RMC permits coronary vessel wall assessment over multiple thin contiguous slices in a clinically feasible duration. Excellent reproducibility of the technique potentially enables studies of disease progression/regression. Copyright © 2010 Wiley-Liss, Inc.

  12. Reproducible statistical analysis with multiple languages

    DEFF Research Database (Denmark)

    Lenth, Russell; Højsgaard, Søren

    2011-01-01

    This paper describes the system for making reproducible statistical analyses. differs from other systems for reproducible analysis in several ways. The two main differences are: (1) Several statistics programs can be in used in the same document. (2) Documents can be prepared using OpenOffice or ......Office or \\LaTeX. The main part of this paper is an example showing how to use and together in an OpenOffice text document. The paper also contains some practical considerations on the use of literate programming in statistics....

  13. Participant Nonnaiveté and the reproducibility of cognitive psychology.

    Science.gov (United States)

    Zwaan, Rolf A; Pecher, Diane; Paolacci, Gabriele; Bouwmeester, Samantha; Verkoeijen, Peter; Dijkstra, Katinka; Zeelenberg, René

    2017-07-25

    Many argue that there is a reproducibility crisis in psychology. We investigated nine well-known effects from the cognitive psychology literature-three each from the domains of perception/action, memory, and language, respectively-and found that they are highly reproducible. Not only can they be reproduced in online environments, but they also can be reproduced with nonnaïve participants with no reduction of effect size. Apparently, some cognitive tasks are so constraining that they encapsulate behavior from external influences, such as testing situation and prior recent experience with the experiment to yield highly robust effects.

  14. Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy

    International Nuclear Information System (INIS)

    Eccles, Cynthia; Brock, Kristy K.; Bissonnette, Jean-Pierre; Hawkins, Maria; Dawson, Laura A.

    2006-01-01

    Purpose: To measure the intrabreath-hold liver motion and the intrafraction and interfraction reproducibility of liver position relative to vertebral bodies using an active breathing coordinator (ABC) in patients with unresectable liver cancer treated with hypofractionated stereotactic body radiation therapy (SBRT). Methods: Tolerability of ABC and organ motion during ABC was assessed using kV fluoroscopy in 34 patients. For patients treated with ABC, repeat breath-hold CT scans in the ABC breath-hold position were acquired at simulation to estimate the volumetric intrafraction reproducibility of the liver relative to the vertebral bodies. In addition, preceding each radiation therapy fraction, with the liver immobilized using ABC, repeat anteroposterior (AP) megavoltage verification images were obtained. Off-line alignments were completed to determine intrafraction reproducibility (from repeat images obtained before one treatment) and interfraction reproducibility (from comparisons of the final image for each fraction with the AP) of diaphragm position relative to vertebral bodies. For each image set, the vertebral bodies were aligned, and the resultant craniocaudal (CC) offset in diaphragm position was measured. Liver position during ABC was also evaluated from kV fluoroscopy acquired at the time of simulation, kV fluoroscopy at the time of treatment, and from MV beam's-eye view movie loops acquired during treatment. Results: Twenty-one of 34 patients were screened to be suitable for ABC. The average free breathing range of these patients was 13 mm (range, 5-1 mm). Fluoroscopy revealed that the average maximal diaphragm motion during ABC breath-hold was 1.4 mm (range, 0-3.4 mm). The MV treatment movie loops confirmed diaphragm stability during treatment. For a measure of intrafraction reproducibility, an analysis of 36 repeat ABC computed tomography (CT) scans in 14 patients was conducted. The average mean difference in the liver surface position was -0.9 mm, -0

  15. Quality control for exposure assessment in epidemiological studies

    DEFF Research Database (Denmark)

    Bornkessel, C; Blettner, M; Breckenkamp, J

    2010-01-01

    In the framework of an epidemiological study, dosemeters were used for the assessment of radio frequency electromagnetic field exposure. To check the correct dosemeter's performance in terms of consistency of recorded field values over the entire study period, a quality control strategy...... was developed. In this paper, the concept of quality control and its results is described. From the 20 dosemeters used, 19 were very stable and reproducible, with deviations of a maximum of +/-1 dB compared with their initial state. One device was found to be faulty and its measurement data had to be excluded...... from the analysis. As a result of continuous quality control procedures, the confidence in the measurements obtained during the field work was strengthened significantly....

  16. Intra-and interobserver reproducibility of shear wave elastography for evaluation of the breast lesions

    International Nuclear Information System (INIS)

    Hong, Min Ji; Kim, Hak Hee

    2017-01-01

    To evaluate reproducibility of shear wave elastography (SWE) for breast lesions within and between observers and compare the reproducibility of SWE features. For intraobserver reproducibility, 225 masses with 208 patients were included; and two consecutive SWE images were acquired by each observer. For interobserver reproducibility, SWE images of the same mass were obtained by another observer before surgery in 40 patients. Intraclass correlation coefficients (ICC) were used to determine intra- and interobserver reproducibility. Intraobserver reliability for mean elasticity (Emean) and maximum elasticity (Emax) were excellent (ICC = 0.803, 0.799). ICC for SWE ratio and minimum elasticity (Emin) were fair to good (ICC = 0.703, 0.539). Emean showed excellent ICC regardless of histopathologic type and tumor size. Emax, SWE ratio and Emin represented excellent or fair to good reproducibility based on histopathologic type and tumor size. In interobserver study, ICC for Emean, Emax and SWE ratio were excellent. Emean, Emax and SWE ratio represented excellent ICC irrespective of histopathologic type. ICC for Emean was excellent regardless of tumor size. SWE ratio and Emax showed fair to good interobserver reproducibility based on tumor size. Emin represented poor interobserver reliability. Emean in SWE was highly reproducible within and between observers

  17. Intra-and interobserver reproducibility of shear wave elastography for evaluation of the breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Min Ji [Dept. of Radiology, Gil Hospital, Gachon University of Medicine and Science, Incheon (Korea, Republic of); Kim, Hak Hee [Dept. of Radiology, and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-03-15

    To evaluate reproducibility of shear wave elastography (SWE) for breast lesions within and between observers and compare the reproducibility of SWE features. For intraobserver reproducibility, 225 masses with 208 patients were included; and two consecutive SWE images were acquired by each observer. For interobserver reproducibility, SWE images of the same mass were obtained by another observer before surgery in 40 patients. Intraclass correlation coefficients (ICC) were used to determine intra- and interobserver reproducibility. Intraobserver reliability for mean elasticity (Emean) and maximum elasticity (Emax) were excellent (ICC = 0.803, 0.799). ICC for SWE ratio and minimum elasticity (Emin) were fair to good (ICC = 0.703, 0.539). Emean showed excellent ICC regardless of histopathologic type and tumor size. Emax, SWE ratio and Emin represented excellent or fair to good reproducibility based on histopathologic type and tumor size. In interobserver study, ICC for Emean, Emax and SWE ratio were excellent. Emean, Emax and SWE ratio represented excellent ICC irrespective of histopathologic type. ICC for Emean was excellent regardless of tumor size. SWE ratio and Emax showed fair to good interobserver reproducibility based on tumor size. Emin represented poor interobserver reliability. Emean in SWE was highly reproducible within and between observers.

  18. Reproducibility of subjective appetite ratings and ad libitum test meal energy intake in overweight and obese males.

    Science.gov (United States)

    Horner, Katy M; Byrne, Nuala M; King, Neil A

    2014-10-01

    To determine whether changes in appetite and energy intake (EI) can be detected and play a role in the effectiveness of interventions, it is necessary to identify their variability under normal conditions. We assessed the reproducibility of subjective appetite ratings and ad libitum test meal EI after a standardised pre-load in overweight and obese males. Fifteen overweight and obese males (BMI 30.3 ± 4.9 kg/m(2), aged 34.9 ± 10.6 years) completed two identical test days, 7 days apart. Participants were provided with a standardised fixed breakfast (1676 kJ) and 5 h later an ad libitum pasta lunch. An electronic appetite rating system was used to assess subjective ratings before and after the fixed breakfast, and periodically during the postprandial period. EI was assessed at the ad libitum lunch meal. Sample size estimates for paired design studies were calculated. Appetite ratings demonstrated a consistent oscillating pattern between test days, and were more reproducible for mean postprandial than fasting ratings. The correlation between ad libitum EI on the two test days was r = 0.78 (P appetite and ad libitum test meal EI in overweight and obese males is comparable to previous reports in normal weight adults. Sample size requirements for studies vary depending on the parameter of interest and sensitivity needed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Reproducing an extreme flood with uncertain post-event information

    Directory of Open Access Journals (Sweden)

    D. Fuentes-Andino

    2017-07-01

    Full Text Available Studies for the prevention and mitigation of floods require information on discharge and extent of inundation, commonly unavailable or uncertain, especially during extreme events. This study was initiated by the devastating flood in Tegucigalpa, the capital of Honduras, when Hurricane Mitch struck the city. In this study we hypothesized that it is possible to estimate, in a trustworthy way considering large data uncertainties, this extreme 1998 flood discharge and the extent of the inundations that followed from a combination of models and post-event measured data. Post-event data collected in 2000 and 2001 were used to estimate discharge peaks, times of peak, and high-water marks. These data were used in combination with rain data from two gauges to drive and constrain a combination of well-known modelling tools: TOPMODEL, Muskingum–Cunge–Todini routing, and the LISFLOOD-FP hydraulic model. Simulations were performed within the generalized likelihood uncertainty estimation (GLUE uncertainty-analysis framework. The model combination predicted peak discharge, times of peaks, and more than 90 % of the observed high-water marks within the uncertainty bounds of the evaluation data. This allowed an inundation likelihood map to be produced. Observed high-water marks could not be reproduced at a few locations on the floodplain. Identifications of these locations are useful to improve model set-up, model structure, or post-event data-estimation methods. Rainfall data were of central importance in simulating the times of peak and results would be improved by a better spatial assessment of rainfall, e.g. from radar data or a denser rain-gauge network. Our study demonstrated that it was possible, considering the uncertainty in the post-event data, to reasonably reproduce the extreme Mitch flood in Tegucigalpa in spite of no hydrometric gauging during the event. The method proposed here can be part of a Bayesian framework in which more events

  20. Ultrasound Assessment of Umbilical Cord Morphology in the First Trimester: A Feasibility Study

    DEFF Research Database (Denmark)

    Narayan, Rajit; Saaid, Rahmah; Pedersen, Lars Henning

    2015-01-01

    Objective: The aim of this study was to determine whether morphology and measurement of the umbilical cord could be accurately assessed at the time of the 11- to 13+6-week scan. Methods: We conducted a prospective study of 100 consecutive women with singleton pregnancies at 11-13+6 weeks' gestation...... be consistently studied in the first trimester. A subjective method of evaluation of the morphology may be a more reproducible technique until measurement strategies are refined and operator experience developed....

  1. Intra- and interobserver reliability and intra-catheter reproducibility using frequency domain optical coherence tomography for the evaluation of morphometric stent parameters and qualitative assessment of stent strut coverage

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Thayssen, Per; Junker, Anders

    2015-01-01

    to investigate the intra- and interobserver reliability, as well as the intra-catheter reproducibility of quantitative FD-OCT-assessment of morphometric stent parameters and qualitative FD-OCT-evaluation of strut coverage in 10 randomly selected 6-month follow-up Nobori® biolimus-eluting stents (N-BESs). METHODS...... in another 10 N-BESs (219 CSAs and 1860 struts) were independently assessed by one of the analysts. RESULTS: The intraobserver variability with regard to relative difference of mean luminal area and mean stent area at the CSA-level was very low: 0.1%±1.4% and 0.5%±3.2%. Interobserver variability also proved...... (CI): 0.88-0.93, pstented coronary segments, and for qualitative assessment of strut coverage....

  2. Reproducibility of a web-based FFQ for 13- to 15-year-old Danish adolescents

    DEFF Research Database (Denmark)

    Bjerregaard, Anne A.; Tetens, Inge; Olsen, Sjurdur F.

    2016-01-01

    the DNBC. Adolescents aged 13 to 15 years old (n 48, 60 % girls) completed the FFQ twice 4 weeks apart. The proportion of adolescents consistently classified into the same tertile according to amount of food intake ranged from 45 % (fish) to 77 % (vegetables), whereas classification into opposite tertiles......FFQ are widely used in large-scale studies to assess dietary intake. To aid interpretation of diet-disease associations assessment of validity must be performed. Reproducibility is one aspect of validity focusing on the stability of repeated assessment with the same method which may also reveal...... ranged from 0 % (fruit, oils and dressing) to 15 % (beverages). Overall, no significant differences were observed in intake of food groups or nutrients between the two completions of the FFQ. Mean crude Spearman correlation for all food groups was 0·56 and mean intra-class correlation for all food groups...

  3. Assessment of mastication in healthy children and children with cerebral palsy: a validity and consistency study.

    Science.gov (United States)

    Remijn, L; Speyer, R; Groen, B E; Holtus, P C M; van Limbeek, J; Nijhuis-van der Sanden, M W G

    2013-05-01

    The aim of this study was to develop the Mastication Observation and Evaluation instrument for observing and assessing the chewing ability of children eating solid and lumpy foods. This study describes the process of item definition and item selection and reports the content validity, reproducibility and consistency of the instrument. In the developmental phase, 15 experienced speech therapists assessed item relevance and descriptions over three Delphi rounds. Potential items were selected based on the results from a literature review. At the initial Delphi round, 17 potential items were included. After three Delphi rounds, 14 items that regarded as providing distinctive value in assessment of mastication (consensus >75%) were included in the Mastication Observation and Evaluation instrument. To test item reproducibility and consistency, two experts and five students evaluated video recordings of 20 children (10 children with cerebral palsy aged 29-65 months and 10 healthy children aged 11-42 months) eating bread and a biscuit. Reproducibility was estimated by means of the intraclass correlation coefficient (ICC). With the exception of one item concerning chewing duration, all items showed good to excellent intra-observer agreement (ICC students: 0.73-1.0). With the exception of chewing duration and number of swallows, inter-observer agreement was fair to excellent for all items (ICC experts: 0.68-1.0 and ICC students: 0.42-1.0). Results indicate that this tool is a feasible instrument and could be used in clinical practice after further research is completed on the reliability of the tool. © 2013 Blackwell Publishing Ltd.

  4. Reproducibility Test for Thermoluminescence Dosimeter (TLD) Using TLD Radpro

    International Nuclear Information System (INIS)

    Nur Khairunisa Zahidi; Ahmad Bazlie Abdul Kadir; Faizal Azrin Abdul Razalim

    2016-01-01

    Thermoluminescence dosimeters (TLD) as one type of dosimeter which are often used to substitute the film badge. Like a film badge, it is worn for a period of time and then must be processed to determine the dose received. This study was to test the reproducibility of TLD using Radpro reader. This study aimed to determine the dose obtained by TLD-100 chips when irradiated with Co-60 gamma source and to test the effectiveness of TLD Radpro reader as a machine to analyse the TLD. Ten chips of TLD -100 were irradiated using Eldorado machine with Co-60 source at a distance of 5 meters from the source with 2 mSv dose exposure. After the irradiation process, TLD-100 chips were read using the TLD Radpro reader. These steps will be repeated for nine times to obtain reproducibility coefficient, r i . The readings of dose obtained from experiment was almost equivalent to the actual dose. Results shows that the average value obtained for reproducibility coefficient, r i is 6.39 % which is less than 10 %. As conclusion, the dose obtained from experiment considered accurate because its value were almost equivalent to the actual dose and TLD Radpro was verified as a good reader to analyse the TLD. (author)

  5. Selecting participants for listening tests of multi-channel reproduced sound

    DEFF Research Database (Denmark)

    Wickelmaier, Florian Maria; Choisel, Sylvain

    2005-01-01

    A selection procedure was devised in order to select listeners for experiments in which their main task will be to judge multichannel reproduced sound. Ninety-one participants filled in a web-based questionnaire. Seventy-eight of them took part in an assessment of their hearing thresholds......, their spatial hearing, and their verbal production abilities. The listeners displayed large individual differences in their performance. Forty subjects were selected based on the test results. The self-assessed listening habits and experience in the web-questionnaire could not predict the results...... of the selection procedure. Further, the hearing thresholds did not correlate with the spatial-hearing test. This leads to the conclusion that task-specific performance tests might be the preferable means of selecting a listening panel....

  6. Selecting participants for listening tests of multi-channel reproduced sound

    DEFF Research Database (Denmark)

    Wickelmaier, Florian; Choisel, Sylvain

    2005-01-01

    A selection procedure was devised in order to select listeners for experiments in which their main task will be to judge multi-channel reproduced sound. 91 participants filled in a web-based questionnaire. 78 of them took part in an assessment of their hearing thresholds, their spatial hearing......, and their verbal production abilities. The listeners displayed large individual differences in their performance. 40 subjects were selected based on the test results. The self-assessed listening habits and experience in the web questionnaire could not predict the results of the selection procedure. Further......, the hearing thresholds did not correlate with the spatial-hearing test. This leads to the conclusion that task-specific performance tests might be the preferable means of selecting a listening panel....

  7. Development, reproducibility and validity of a food frequency questionnaire among pregnant women adherent to the Mediterranean dietary pattern.

    Science.gov (United States)

    Papazian, Tatiana; Hout, Hala; Sibai, Darine; Helou, Nour; Younes, Hassan; El Osta, Nada; Khabbaz, Lydia Rabbaa

    2016-12-01

    Accurate dietary assessment tools are required to ensure that maternal diet supplies all the nutrients needed for fetal development. However, no dietary method could accurately estimate food intake during gestation. Food Frequency Questionnaires (FFQ), frequently used in epidemiological studies, estimate long term nutritional status of the target population. However, it is recommended to create and validate a FFQ compatible with the dietary habits of the studied population, to avoid cultural and social discrepancies. This study aimed to develop and test the reproducibility and the validity of a semi-quantitative FFQ compatible with the diet of Mediterranean and Middle-Eastern population, in a sample of Lebanese pregnant women. 128 women participated in the validation study, while 38 took part in the reproducibility phase, which was repeated in a time frame of 21 days. The FFQ was validated against a 24 h dietary recall (DR). The intra class correlation coefficient (ICC) ranged from 0.935 for calcium to 0.984 for vitamin D (p value food items was culture specific and assessed the nutrient intake of our population. Administering this tool in future researches will help monitor the nutritional status of pregnant women, aiming at improving maternal and newborn health. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  8. Atopy patch tests in young adult patients with atopic dermatitis and controls: dose-response relationship, objective reading, reproducibility and clinical interpretation.

    Science.gov (United States)

    Bygum, Anette; Mortz, Charlotte Gotthard; Andersen, Klaus Ejner

    2003-01-01

    The clinical interpretation and reproducibility of atopy patch tests was studied in 23 selected young adult patients with atopic dermatitis and 25 healthy controls using standard inhalant allergens. Non-invasive measurements were used for objective assessment of test reactions and the participants were retested after 6 weeks. Ten of 19 (53%) evaluable patients with atopic dermatitis had at least one positive atopy patch test. However, there was no clear clinical relevance of the atopy patch test results when related to patient history and distribution of dermatitis. Reproducible and dose-dependent results were obtained with Dermatophagoides pteronyssinus, grass and cat with a reproducibility rate of 0.69 to 0.81 in patients and 0.60-0.96 in controls. A unique finding was a significant positive correlation between a positive atopy patch test, allergen dose and increase in transepidermal water loss and erythema, while measurement of capacitance did not distinguish between positive and negative reactions. The results of the present study do not support the routine use of atopy patch tests in the evaluation of adult patients with atopic dermatitis.

  9. REPRODUCIBILITY OF MACULAR PIGMENT OPTICAL DENSITY MEASUREMENT BY TWO-WAVELENGTH AUTOFLUORESCENCE IN A CLINICAL SETTING.

    Science.gov (United States)

    You, Qi Sheng; Bartsch, Dirk-Uwe G; Espina, Mark; Alam, Mostafa; Camacho, Natalia; Mendoza, Nadia; Freeman, William R

    2016-07-01

    Macular pigment, composed of lutein, zeaxanthin, and meso-zeaxanthin, is postulated to protect against age-related macular degeneration, likely because of filtering blue light and its antioxidant properties. Macular pigment optical density (MPOD) is reported to be associated with macular function evaluated by visual acuity and multifocal electroretinogram. Given the importance of macular pigment, reliable and accurate measurement methods are important. The main purpose of this study is to determine the reproducibility of MPOD measurement by two-wavelength autofluorescence method using scanning laser ophthalmoscopy. Sixty-eight eyes of 39 persons were enrolled in the study, including 11 normal eyes, 16 eyes with wet age-related macular degeneration, 16 eyes with dry age-related macular degeneration, 11 eyes with macular edema due to diabetic mellitus, branch retinal vein occlusion or macular telangiectasia, and 14 eyes with tractional maculopathy, including vitreomacular traction, epiretinal membrane, or macular hole. MPOD was measured with a two-wavelength (488 and 514 nm) autofluorescence method with the Spectralis HRA + OCT after pupil dilation. The measurement was repeated for each eye 10 minutes later. The analysis of variance and Bland-Altman plot were used to assess the reproducibility between the two measurements. The mean MPOD at eccentricities of 1° and 2° was 0.36 ± 0.17 (range: 0.04-0.69) and 0.15 ± 0.08 (range: -0.03 to 0.35) for the first measurement and 0.35 ± 0.17 (range: 0.02-0.68) and 0.15 ± 0.08 (range: -0.01 to 0.33) for the second measurement, respectively. The difference between the 2 measurements was not statistically significant, and the Bland-Altman plot showed 7.4% and 5.9% points outside the 95% limits of agreement, indicating an overall excellent reproducibility. Similarly, there is no significant difference between the first and second measurements of MPOD volume within eccentricities of 1°, 2°, and 6° radius, and the Bland

  10. An automated procedure for the assessment of white matter hyperintensities by multispectral (T1, T2, PD) MRI and an evaluation of its between-centre reproducibility based on two large community databases

    International Nuclear Information System (INIS)

    Maillard, Pauline; Delcroix, Nicolas; Crivello, Fabrice; Gicquel, Sebastien; Joliot, Marc; Tzourio-Mazoyer, Nathalie; Dufouil, Carole; Alperovitch, Annick; Tzourio, Christophe; Mazoyer, Bernard

    2008-01-01

    An automated procedure for the detection, quantification, localization and statistical mapping of white matter hyperintensities (WMH) on T2-weighted magnetic resonance (MR) images is presented and validated based on the results of a between-centre reproducibility study. The first step is the identification of white matter (WM) tissue using a multispectral (T1, T2, PD) segmentation. In a second step, WMH are identified within the WM tissue by segmenting T2 images, isolating two different classes of WMH voxels - low- and high-contrast WMH voxels, respectively. The reliability of the whole procedure was assessed by applying it to the analysis of two large MR imaging databases (n = 650 and n710, respectively) of healthy elderly subjects matched for demographic characteristics. Average overall WMH load and spatial distribution were found to be similar in the two samples, (1.81 and 1.79% of the WM volume, respectively). White matter hyperintensity load was found to be significantly associated with both age and high blood pressure, with similar effects in both samples. With specific reference to the 650 subject cohort, we also found that WMH load provided by this automated procedure was significantly associated with visual grading of the severity of WMH, as assessed by a trained neurologist. The results show that this method is sensitive, well correlated with semi-quantitative visual rating and highly reproducible. (orig.)

  11. An automated procedure for the assessment of white matter hyperintensities by multispectral (T1, T2, PD) MRI and an evaluation of its between-centre reproducibility based on two large community databases

    Energy Technology Data Exchange (ETDEWEB)

    Maillard, Pauline; Delcroix, Nicolas; Crivello, Fabrice; Gicquel, Sebastien; Joliot, Marc; Tzourio-Mazoyer, Nathalie [GIP Cyceron, Centre d' Imagerie-Neurosciences et Applications aux Pathologies, CI-NAPS, CNRS, CEA, Universite de Caen/Universite Paris Descartes, Boulevard Becquerel, BP 5229, Caen (France); Dufouil, Carole; Alperovitch, Annick; Tzourio, Christophe [Universite Pierre et Marie Curie, INSERM U708, Neuroepidemiologie, Paris (France); Mazoyer, Bernard [GIP Cyceron, Centre d' Imagerie-Neurosciences et Applications aux Pathologies, CI-NAPS, CNRS, CEA, Universite de Caen/Universite Paris Descartes, Boulevard Becquerel, BP 5229, Caen (France); Institut Universitaire de France, Paris (France); CHU du Caen, Unite IRM, Caen (France)

    2008-01-15

    An automated procedure for the detection, quantification, localization and statistical mapping of white matter hyperintensities (WMH) on T2-weighted magnetic resonance (MR) images is presented and validated based on the results of a between-centre reproducibility study. The first step is the identification of white matter (WM) tissue using a multispectral (T1, T2, PD) segmentation. In a second step, WMH are identified within the WM tissue by segmenting T2 images, isolating two different classes of WMH voxels - low- and high-contrast WMH voxels, respectively. The reliability of the whole procedure was assessed by applying it to the analysis of two large MR imaging databases (n = 650 and n= 710, respectively) of healthy elderly subjects matched for demographic characteristics. Average overall WMH load and spatial distribution were found to be similar in the two samples, (1.81 and 1.79% of the WM volume, respectively). White matter hyperintensity load was found to be significantly associated with both age and high blood pressure, with similar effects in both samples. With specific reference to the 650 subject cohort, we also found that WMH load provided by this automated procedure was significantly associated with visual grading of the severity of WMH, as assessed by a trained neurologist. The results show that this method is sensitive, well correlated with semi-quantitative visual rating and highly reproducible. (orig.)

  12. Relevant principal factors affecting the reproducibility of insect primary culture.

    Science.gov (United States)

    Ogata, Norichika; Iwabuchi, Kikuo

    2017-06-01

    The primary culture of insect cells often suffers from problems with poor reproducibility in the quality of the final cell preparations. The cellular composition of the explants (cell number and cell types), surgical methods (surgical duration and surgical isolation), and physiological and genetic differences between donors may be critical factors affecting the reproducibility of culture. However, little is known about where biological variation (interindividual differences between donors) ends and technical variation (variance in replication of culture conditions) begins. In this study, we cultured larval fat bodies from the Japanese rhinoceros beetle, Allomyrina dichotoma, and evaluated, using linear mixed models, the effect of interindividual variation between donors on the reproducibility of the culture. We also performed transcriptome analysis of the hemocyte-like cells mainly seen in the cultures using RNA sequencing and ultrastructural analyses of hemocytes using a transmission electron microscope, revealing that the cultured cells have many characteristics of insect hemocytes.

  13. Liquid scintigraphic gastric emptying - is it reproducible?

    International Nuclear Information System (INIS)

    Cooper, R.G.; Shuter, B.; Leach, M.; Roach, P.J.

    1999-01-01

    Full text: Radioisotope gastric emptying (GE) studies have been used as a non-invasive technique for motility assessment for many years. In a recent study investigating the correlation of mesenteric vascular changes with GE, six subjects had a repeat study 2-4 months later. Repeat studies were required due to minor technical problems (5 subjects) and a very slow GE (I subject) on the original study. Subjects drank 275 ml of 'Ensure Plus' mixed with 8 MBq 67 Ga-DTPA and were imaged for 2 h while lying supine. GE time-activity curves for each subject were generated and time to half emptying (T l/2 ) calculated. Five of the six subjects had more rapid GE on the second study. Three of the subjects had T l/2 values on their second study which were within ± 15 min of their original T l/2 . The other three subjects had T l/2 values on their second study which were 36 min, 55 min and 280 min (subject K.H.) less than their original T l/2 . Statistical analysis (t-test) was performed on paired T l/2 values. The average T l/2 value was greater in the first study than in the second (149 ± 121 and 86 ± 18 min respectively), although the difference was not statistically significant (P ∼ 0.1). Subjects' anxiety levels were not quantitated during the GE study; however, several major equipment faults occurred during the original study of subject K.H., who became visibly stressed. These results suggest that the reproducibility of GE studies may be influenced by psychological factors

  14. Reproducibility of urodynamic filling sensation at weekly interval in healthy volunteers and in women with detrusor overactivity.

    Science.gov (United States)

    Van Meel, Tom David; Wyndaele, Jean-Jacques

    2011-11-01

    To evaluate the reproducibility of bladder sensation during standardized filling cystometry in female volunteers and overactive bladder (OAB) patients, repeated with weekly interval. We recruited 13 female nulliparous volunteers (age 21-47) and 17 female patients with OAB between (age 18-72). They participated in three investigation periods, each separated by 7 days to assess reproducibility of sensation related to standardized cystometry. Subjects were asked to report all sensations they felt during bladder filling. The previously described pattern of sensation was reported during bladder filling in all. Consecutive sensations corresponded to statistically higher bladder volumes. Volumes, at which different sensations of bladder filling were reported, were significantly higher in controls than in OAB patients [first sensation of filling (FSF) P = 0.003, first desire to void (FDV) P sensation/volume ratios were significantly higher in patients with OAB than in the healthy volunteers: FSF occurred at mean 46% and FDV at mean 73% of SDV in OAB patients, compared to 36% and 64% in healthy volunteers. Sensations proved highly reproducible when determined with weekly interval. Our data demonstrate that cystometric filling sensation determined in a standardized way with weekly interval is highly reproducible in healthy and in OAB patients. This finding has, in our opinion, clinical importance as it shows that the technique is reliable both for a sensory evaluation of the LUT as to study influence of treatment aimed at changing this sensation. Copyright © 2011 Wiley Periodicals, Inc.

  15. On the Reproducibility of Label-Free Quantitative Cross-Linking/Mass Spectrometry

    Science.gov (United States)

    Müller, Fränze; Fischer, Lutz; Chen, Zhuo Angel; Auchynnikava, Tania; Rappsilber, Juri

    2018-02-01

    Quantitative cross-linking/mass spectrometry (QCLMS) is an emerging approach to study conformational changes of proteins and multi-subunit complexes. Distinguishing protein conformations requires reproducibly identifying and quantifying cross-linked peptides. Here we analyzed the variation between multiple cross-linking reactions using bis[sulfosuccinimidyl] suberate (BS3)-cross-linked human serum albumin (HSA) and evaluated how reproducible cross-linked peptides can be identified and quantified by LC-MS analysis. To make QCLMS accessible to a broader research community, we developed a workflow that integrates the established software tools MaxQuant for spectra preprocessing, Xi for cross-linked peptide identification, and finally Skyline for quantification (MS1 filtering). Out of the 221 unique residue pairs identified in our sample, 124 were subsequently quantified across 10 analyses with coefficient of variation (CV) values of 14% (injection replica) and 32% (reaction replica). Thus our results demonstrate that the reproducibility of QCLMS is in line with the reproducibility of general quantitative proteomics and we establish a robust workflow for MS1-based quantitation of cross-linked peptides.

  16. Short-term displacement and reproducibility of the breast and nodal targets under active breathing control

    NARCIS (Netherlands)

    Moran, Jean M.; Balter, James M.; Ben-David, Merav A.; Marsh, Robin B.; van Herk, Marcel; Pierce, Lori J.

    2007-01-01

    PURPOSE: The short-term displacement and reproducibility of the breast or chest wall, and the internal mammary (IM), infraclavicular (ICV), and supraclavicular (SCV) nodal regions have been assessed as a function of breath-hold state using an active breathing control (ABC) device for patients

  17. Beyond Bundles - Reproducible Software Environments with GNU Guix

    CERN Multimedia

    CERN. Geneva; Wurmus, Ricardo

    2018-01-01

    Building reproducible data analysis pipelines and numerical experiments is a key challenge for reproducible science, in which tools to reproduce software environments play a critical role. The advent of “container-based” deployment tools such as Docker and Singularity has made it easier to replicate software environments. These tools are very much about bundling the bits of software binaries in a convenient way, not so much about describing how software is composed. Science is not just about replicating, though—it demands the ability to inspect and to experiment. In this talk we will present GNU Guix, a software management toolkit. Guix departs from container-based solutions in that it enables declarative composition of software environments. It is comparable to “package managers” like apt or yum, but with a significant difference: Guix provides accurate provenance tracking of build artifacts, and bit-reproducible software. We will illustrate the many ways in which Guix can improve how software en...

  18. Banff initiative for quality assurance in transplantation (BIFQUIT): reproducibility of C4d immunohistochemistry in kidney allografts.

    Science.gov (United States)

    Mengel, M; Chan, S; Climenhaga, J; Kushner, Y B; Regele, H; Colvin, R B; Randhawa, P

    2013-05-01

    Detection of C4d is crucial for diagnosing antibody-mediated-rejection. We conducted a multicenter trial to assess the reproducibility for C4d immunohistochemistry on paraffin tissue. Unstained slides from a tissue microarray (TMA) comprising 44 kidney allograft specimens representing a full analytical spectrum for C4d were distributed to 73 institutions. Participants stained TMA slides using local protocols and evaluated their slides following the Banff C4d schema. Local staining details and evaluation scores were collected online. Stained slides were returned for centralized panel re-evaluation. Kappa statistics were used to determine reproducibility. Poor interinstitutional reproducibility was observed (kappa 0.17), which was equally due to limitations in interobserver (kappa 0.44) and interlaboratory reproducibility (kappa 0.46). Depending on the cut-off, reproducibility could be improved by omitting C4d grading and only considering ± calls. Heat-induced epitope recovery (pH 6-7, 20-30 min, citrate buffer) with polyclonal antibody incubation (40 min) appeared as best practice. The BIFQUIT trial results indicated that C4d staining on paraffin sections varies considerably between laboratories. Refinement of the current Banff C4d scoring schema and harmonization of tissue processing and staining protocols is necessary to achieve acceptable reproducibility. © Copyright 2013 The American Society of Transplantation and the American Society of Transplant Surgeons.

  19. ZIF-8 Membranes with Improved Reproducibility Fabricated from Sputter-Coated ZnO/Alumina Supports

    KAUST Repository

    Yu, Jian; Pan, Yichang; Wang, Chongqing; Lai, Zhiping

    2015-01-01

    for reproducible fabrication of high-quality membranes. In this study, high-quality ZIF-8 membranes were prepared through hydrothermal synthesis under the partial self-conversion of sputter-coated ZnO layer on porous α-alumina supports. The reproducibility

  20. Reproducibility and validity of the Dutch translation of the de Morton Mobility Index (DEMMI) used by physiotherapists in older patients with knee or hip osteoarthritis.

    Science.gov (United States)

    Jans, Marielle P; Slootweg, Vera C; Boot, Cecile R; de Morton, Natalie A; van der Sluis, Geert; van Meeteren, Nico L

    2011-11-01

    To examine the reproducibility, construct validity, and unidimensionality of the Dutch translation of the de Morton Mobility Index (DEMMI), a performance-based measure of mobility for older patients. Cross-sectional study. Rehabilitation center (reproducibility study) and hospital (validity study). Patients (N=28; age >65y) after orthopedic surgery (reproducibility study) and patients (N=219; age >65y) waiting for total hip or total knee arthroplasty (validity study). Not applicable. Not applicable. The intraclass correlation coefficient for interrater reliability was high (.85; 95% confidence interval, 71-.93), and minimal detectable change with 90% confidence was 7 on the 100-point DEMMI scale. Rasch analysis identified that the Dutch translation of the DEMMI is a unidimensional measure of mobility in this population. DEMMI scores showed high correlations with scores on other performance-based measures of mobility (Timed Up and Go test, Spearman r=-.73; Chair Rise Time, r=-.69; walking test, r=.74). A lower correlation of .44 was identified with the self-report measure Western Ontario and McMaster Universities Osteoarthritis Index. The Dutch translation of the DEMMI is a reproducible and valid performance-based measure for assessing mobility in older patients with knee or hip osteoarthritis. Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  1. Reproducibility and calibration studies of TLD 600, TLD 700 and TLD 400

    International Nuclear Information System (INIS)

    Cavalieri, T.A.; Castro, V.A.; Siqueira, P.T.D.

    2013-01-01

    A new method to study of reproducibility of the thermoluminescent dosimeters (TLDs) and their calibration was carried on and compared with the method previously used by the BNCT research group of IPEN/CNEN. In this new method, aimed to identify the relations between the individual response of certain types of TLDs with their average response, it was observed a relation approximately constant even at different irradiations. From these relations, normalization of TLDs responses were made, and this method was compared with the method previously adopted by BNCT research group of IPEN/CNEN given better responses. With this new method, the dose response calibration o were made for two gamma sources, with different energies, 60 Co and 137 Cs, for doses ranging from 20 mGy to 1 Gy, and it has been possible to observe the response dependence of these TLDs on energy. (author)

  2. ReproPhylo: An Environment for Reproducible Phylogenomics.

    Directory of Open Access Journals (Sweden)

    Amir Szitenberg

    2015-09-01

    Full Text Available The reproducibility of experiments is key to the scientific process, and particularly necessary for accurate reporting of analyses in data-rich fields such as phylogenomics. We present ReproPhylo, a phylogenomic analysis environment developed to ensure experimental reproducibility, to facilitate the handling of large-scale data, and to assist methodological experimentation. Reproducibility, and instantaneous repeatability, is built in to the ReproPhylo system and does not require user intervention or configuration because it stores the experimental workflow as a single, serialized Python object containing explicit provenance and environment information. This 'single file' approach ensures the persistence of provenance across iterations of the analysis, with changes automatically managed by the version control program Git. This file, along with a Git repository, are the primary reproducibility outputs of the program. In addition, ReproPhylo produces an extensive human-readable report and generates a comprehensive experimental archive file, both of which are suitable for submission with publications. The system facilitates thorough experimental exploration of both parameters and data. ReproPhylo is a platform independent CC0 Python module and is easily installed as a Docker image or a WinPython self-sufficient package, with a Jupyter Notebook GUI, or as a slimmer version in a Galaxy distribution.

  3. Reproducibility in Computational Neuroscience Models and Simulations

    Science.gov (United States)

    McDougal, Robert A.; Bulanova, Anna S.; Lytton, William W.

    2016-01-01

    Objective Like all scientific research, computational neuroscience research must be reproducible. Big data science, including simulation research, cannot depend exclusively on journal articles as the method to provide the sharing and transparency required for reproducibility. Methods Ensuring model reproducibility requires the use of multiple standard software practices and tools, including version control, strong commenting and documentation, and code modularity. Results Building on these standard practices, model sharing sites and tools have been developed that fit into several categories: 1. standardized neural simulators, 2. shared computational resources, 3. declarative model descriptors, ontologies and standardized annotations; 4. model sharing repositories and sharing standards. Conclusion A number of complementary innovations have been proposed to enhance sharing, transparency and reproducibility. The individual user can be encouraged to make use of version control, commenting, documentation and modularity in development of models. The community can help by requiring model sharing as a condition of publication and funding. Significance Model management will become increasingly important as multiscale models become larger, more detailed and correspondingly more difficult to manage by any single investigator or single laboratory. Additional big data management complexity will come as the models become more useful in interpreting experiments, thus increasing the need to ensure clear alignment between modeling data, both parameters and results, and experiment. PMID:27046845

  4. Reproducible localization of interictal epileptiform discharges using EEG-triggered fMRI

    International Nuclear Information System (INIS)

    Symms, M.R.; Allen, P.J.; Fish, D.R.; Barker, G.J.

    1999-01-01

    We report preliminary experiences using fMRI triggered by EEG to localize the site of interictal epileptiform activity. EEG was recorded in the scanner and monitored on-line; the recording quality was good enough to allow the clear identification of spikes in the EEG. Snap-shot EPI was performed 2-4 s after an epileptiform discharge ('spike') or after at least 10 s of background activity ('rest') was observed. A pixel-by-pixel t-test was performed between the 'rest' and the 'spike' images to determine areas of significant activation. Significant activation was obtained in a patient with epilepsy. To assess the reliability and reproducibility of the technique, the patient was scanned on four separate occasions with similar areas being activated in all the studies, confirming the validity of the result. (author)

  5. On the use of MOZAIC-IAGOS data to assess the ability of the MACC reanalysis to reproduce the distribution of ozone and CO in the UTLS over Europe

    Directory of Open Access Journals (Sweden)

    Audrey Gaudel

    2015-12-01

    Full Text Available MOZAIC-IAGOS data are used to assess the ability of the MACC reanalysis (REAN to reproduce distributions of ozone (O3 and carbon monoxide (CO, along with vertical and inter-annual variability in the upper troposphere/lower stratosphere region (UTLS over Europe for the period 2003–2010. A control run (CNTRL, without assimilation is compared with the MACC reanalysis (REAN, with assimilation to assess the impact of assimilation. On average over the period, REAN underestimates ozone by 60 ppbv in the lower stratosphere (LS, whilst CO is overestimated by 20 ppbv. In the upper troposphere (UT, ozone is overestimated by 50 ppbv, while CO is partly over or underestimated by up to 20 ppbv. As expected, assimilation generally improves model results but there are some exceptions. Assimilation leads to increased CO mixing ratios in the UT which reduce the biases of the model in this region but the difference in CO mixing ratios between LS and UT has not changed and remains underestimated after assimilation. Therefore, this leads to a significant positive bias of CO in the LS after assimilation. Assimilation improves estimates of the amplitude of the seasonal cycle for both species. Additionally, the observations clearly show a general negative trend of CO in the UT which is rather well reproduced by REAN. However, REAN misses the observed inter-annual variability in summer. The O3–CO correlation in the Ex-UTLS is rather well reproduced by the CNTRL and REAN, although REAN tends to miss the lowest CO mixing ratios for the four seasons and tends to oversample the extra-tropical transition layer (ExTL region in spring. This evaluation stresses the importance of the model gradients for a good description of the mixing in the Ex-UTLS region, which is inherently difficult to observe from satellite instruments.

  6. Reproducibility of 5-HT2A receptor measurements and sample size estimations with [18F]altanserin PET using a bolus/infusion approach

    DEFF Research Database (Denmark)

    Haugbøl, Steven; Pinborg, Lars H; Arfan, Haroon M

    2006-01-01

    PURPOSE: To determine the reproducibility of measurements of brain 5-HT2A receptors with an [18F]altanserin PET bolus/infusion approach. Further, to estimate the sample size needed to detect regional differences between two groups and, finally, to evaluate how partial volume correction affects...... reproducibility and the required sample size. METHODS: For assessment of the variability, six subjects were investigated with [18F]altanserin PET twice, at an interval of less than 2 weeks. The sample size required to detect a 20% difference was estimated from [18F]altanserin PET studies in 84 healthy subjects....... Regions of interest were automatically delineated on co-registered MR and PET images. RESULTS: In cortical brain regions with a high density of 5-HT2A receptors, the outcome parameter (binding potential, BP1) showed high reproducibility, with a median difference between the two group measurements of 6...

  7. Reproducibility of computer-aided detection system in digital mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Cho, Nariya; Cha, Joo Hee; Chung, Hye Kyung; Lee, Sin Ho; Cho, Kyung Soo; Kim, Sun Mi; Moon, Woo Kyung

    2005-01-01

    To evaluate the reproducibility of the computer-aided detection (CAD) system for digital mammograms. We applied the CAD system (ImageChecker M1000-DM, version 3.1; R2 Technology) to full field digital mammograms. These mammograms were taken twice at an interval of 10-45 days (mean:25 days) for 34 preoperative patients (breast cancer n=27, benign disease n=7, age range:20-66 years, mean age:47.9 years). On the mammograms, lesions were visible in 19 patients and these were depicted as 15 masses and 12 calcification clusters. We analyzed the sensitivity, the false positive rate (FPR) and the reproducibility of the CAD marks. The broader sensitivities of the CAD system were 80% (12 of 15), 67%(10 of 15) for masses and those for calcification clusters were 100% (12 of 12). The strict sensitivities were 50% (15 of 30) and 50% (15 of 30) for masses and 92% (22 of 24) and 79% (19 of 24) for the clusters. The FPR for the masses was 0.21-0.22/image, the FPR for the clusters was 0.03-0.04/image and the total FPR was 0.24-0.26/image. Among 132 mammography images, the identical images regardless of the existence of CAD marks were 59% (78 of 132), and the identical images with CAD marks were 22% (15 of 69). The reproducibility of the CAD marks for the true positive mass was 67% (12 of 18) and 71% (17 of 24) for the true positive cluster. The reproducibility of CAD marks for the false positive mass was 8% (4 of 53), and the reproducibility of CAD marks for the false positive clusters was 14% (1 of 7). The reproducibility of the total mass marks was 23% (16 of 71), and the reproducibility of the total cluster marks was 58% (18 of 31). CAD system showed higher sensitivity and reproducibility of CAD marks for the calcification clusters which are related to breast cancer. Yet the overall reproducibility of CAD marks was low; therefore, the CAD system must be applied considering this limitation

  8. Reproducibility of mass spectrometry based protein profiles for diagnosis of breast cancer across clinical studies

    DEFF Research Database (Denmark)

    Callesen, Anne Kjærgaard; Vach, Werner; Jørgensen, Per E

    2008-01-01

    Serum protein profiling by mass spectrometry has achieved attention as a promising technology in oncoproteomics. We performed a systematic review of published reports on protein profiling as a diagnostic tool for breast cancer. The MEDLINE, EMBASE, and COCHRANE databases were searched for original...... studies reporting discriminatory protein peaks for breast cancer as either protein identity or as m/ z values in the period from January 1995 to October 2006. To address the important aspect of reproducibility of mass spectrometry data across different clinical studies, we compared the published lists...... of potential discriminatory peaks with those peaks detected in an original MALDI MS protein profiling study performed by our own research group. A total of 20 protein/peptide profiling studies were eligible for inclusion in the systematic review. Only 3 reports included information on protein identity...

  9. Reproducibility of image quality for moving objects using respiratory-gated computed tomography. A study using a phantom model

    International Nuclear Information System (INIS)

    Fukumitsu, Nobuyoshi; Ishida, Masaya; Terunuma, Toshiyuki

    2012-01-01

    To investigate the reproducibility of computed tomography (CT) imaging quality in respiratory-gated radiation treatment planning is essential in radiotherapy of movable tumors. Seven series of regular and six series of irregular respiratory motions were performed using a thorax dynamic phantom. For the regular respiratory motions, the respiratory cycle was changed from 2.5 to 4 s and the amplitude was changed from 4 to 10 mm. For the irregular respiratory motions, a cycle of 2.5 to 4 or an amplitude of 4 to 10 mm was added to the base data (id est (i.e.) 3.5-s cycle, 6-mm amplitude) every three cycles. Images of the object were acquired six times using respiratory-gated data acquisition. The volume of the object was calculated and the reproducibility of the volume was decided based on the variety. The registered image of the object was added and the reproducibility of the shape was decided based on the degree of overlap of objects. The variety in the volumes and shapes differed significantly as the respiratory cycle changed according to regular respiratory motions. In irregular respiratory motion, shape reproducibility was further inferior, and the percentage of overlap among the six images was 35.26% in the 2.5- and 3.5-s cycle mixed group. Amplitude changes did not produce significant differences in the variety of the volumes and shapes. Respiratory cycle changes reduced the reproducibility of the image quality in respiratory-gated CT. (author)

  10. [HPV primary test in the cervical cancer screening: reproducibility assessment and investigation on cytological outcome of Hybrid Capture 2 borderline samples].

    Science.gov (United States)

    Burroni, Elena; Sani, Cristina; Bisanzi, Simonetta; Ocello, Cristina

    2016-01-01

    to evaluate the reproducibility of the High-Risk Hybrid Capture 2 (HC2-HR, Qiagen) test within the frame of cervical cancer screening with HPV, for samples with values very close to the cut-off (borderline), that is 0.80≤RLU/CO≤0.99 (RLU/CO: relative light units/cut-off) and to assess any possible presence of high grade lesions. all borderline samples collected from January 2014 to August 2015 were repeated with HR-HC2 test within two weeks from the first test. For HPV-positive samples, cytology and colposcopy results (if present) were analysed. national and international directions recommend the use of HPV testing as a primary test for cervical cancer screening for women aged 30/34-64 years. In Tuscany Region (Central Italy) the primary screening with HPV test was introduced in 2013 and the HPV test currently used, HR-HC2, has a positive cut-off≥1 RLU/CO. proportion of HPV-positive tests at repetition, then stratified by type of material (ThinPrep, STM) and for the following subclasses of RLU/CO: 0.80-0.89 and 0.90-0.99. 253 samples were borderline at first test with HR-HC2 (about 0.4% of all samples tested). About 83% (209/253) of the samples was confirmed to be negative at the HPV test repetition: 88% for RLU/CO=0.80-0.89 and 76% for RLU/CO=0.90-0.99 (p-value=0.014). Median RLU/CO value of 44 HPV-positive samples at repetition is 1.4, with a maximum RLU/CO value of 16.7. In addition, 90% of HPV-positive samples at repetition has a RLU/CO values below or equal to 3.6. Even the used sampling system affects reproducibility: 26.4% (33/125) of the samples resulted positive at the repetition were in ThinPrep vs. 8.6% (11/128) of those in STM (p-valuecut-off (0.90-0.99), confirming the intrinsic limit to all analytical methods near to the cut-off. Moreover, even if the difference in reproducibility between the two systems of sampling is statistically significant, in samples that resulted positive at repetition high-grade lesions were not found at the time of HPV

  11. The relative validity and reproducibility of an iron food frequency questionnaire for identifying iron-related dietary patterns in young women.

    Science.gov (United States)

    Beck, Kathryn L; Kruger, Rozanne; Conlon, Cathryn A; Heath, Anne-Louise M; Coad, Jane; Matthys, Christophe; Jones, Beatrix; Stonehouse, Welma

    2012-08-01

    Using food frequency data to identify dietary patterns is a newly emerging approach to assessing the relationship between dietary intake and iron status. Food frequency questionnaires should be assessed for validity and reproducibility before use. We aimed to investigate the relative validity and reproducibility of an iron food frequency questionnaire (FeFFQ) specifically designed to identify iron-related dietary patterns. Participants completed the FeFFQ at baseline (FeFFQ1) and 1 month later (FeFFQ2) to assess reproducibility. A 4-day weighed diet record (4DDR) was completed between these assessments to determine validity. Foods appearing in the 4DDR were classified into the same 144 food groupings as the FeFFQ. Factor analysis was used to determine dietary patterns from FeFFQ1, FeFFQ2, and the 4DDR. A convenience sample of women (n=115) aged 18 to 44 years living in Auckland, New Zealand, during 2009. Agreement between diet pattern scores was compared using correlation coefficients, Bland-Altman analysis, cross-classification, and the weighted κ statistic. A "healthy" and a "sandwich and drinks" dietary pattern were identified from all three dietary assessments. Correlation coefficients between FeFFQ1 and the 4DDR diet pattern scores (validity) were 0.34 for the healthy, and 0.62 for the sandwich and drinks pattern (both Ps50% of participants into the correct tertile and <10% into the opposite tertile for both the healthy and sandwich and drinks diet pattern scores when compared with the 4DDR and FeFFQ2. The FeFFQ appears to be a reproducible and relatively valid method for identifying dietary patterns, and could be used to investigate the relationship between dietary patterns and iron status. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  12. Reproducibility of whole-body {sup 131}I scan and serum thyrotropin and stimulated thyroglobulin values in patients studied twice after injection of recombinant human thyrotropin

    Energy Technology Data Exchange (ETDEWEB)

    Niederkohr, Ryan D.; McDougall, I.R. [Stanford University Medical Center, Division of Nuclear Medicine, Stanford, CA (United States)

    2007-03-15

    Recombinant human TSH (rhTSH) is used to increase radioiodine uptake during imaging of thyroid cancer, obviating the need to render the patient hypothyroid. We assessed the reproducibility of radioiodine uptake, serum thyrotropin (TSH), and stimulated serum thyroglobulin (Tg) levels after rhTSH administration. A retrospective review was performed of patients at Stanford who underwent whole-body {sup 131}I scanning for surveillance of thyroid cancer twice after thyroidectomy and {sup 131}I ablation, with rhTSH prior to each scan. Forty-eight hour radioiodine uptake, peak serum TSH, and stimulated serum Tg levels for each study were recorded. Paired t tests and correlation analysis were used to assess interexamination repeatability. Twenty-three patients underwent two scintiscans with rhTSH, for a total of 46 exams. There was no significant difference between percent uptake at 48 h in the paired exams (p=0.40). Serum TSH level was measured in 45 of 46 exams; TSH exceeded 50 mIU/l in all cases, and there was no significant difference between paired TSH levels (p=0.93). All patients had stimulated serum Tg levels measured, with no significant difference between paired Tg levels (p=0.40); after excluding one patient whose Tg changed from 15.8 ng/ml to undetectable between scans without interval treatment, the p value rose to 0.95. There was a strong correlation among paired uptake values (r=0.85, p<0.0001), peak serum TSH (r=0.69, p=0.0003), and stimulated Tg levels (r=0.81, p<0.0001). No discordant scan interpretations were reported. Forty-eight hour radioiodine uptake, peak serum TSH, and stimulated serum Tg levels after administration of rhTSH are repeatable between studies, demonstrating reproducibility of diagnostic results without rendering patients hypothyroid. (orig.)

  13. Reproducibility of UAV-based earth surface topography based on structure-from-motion algorithms.

    Science.gov (United States)

    Clapuyt, François; Vanacker, Veerle; Van Oost, Kristof

    2014-05-01

    A representation of the earth surface at very high spatial resolution is crucial to accurately map small geomorphic landforms with high precision. Very high resolution digital surface models (DSM) can then be used to quantify changes in earth surface topography over time, based on differencing of DSMs taken at various moments in time. However, it is compulsory to have both high accuracy for each topographic representation and consistency between measurements over time, as DSM differencing automatically leads to error propagation. This study investigates the reproducibility of reconstructions of earth surface topography based on structure-from-motion (SFM) algorithms. To this end, we equipped an eight-propeller drone with a standard reflex camera. This equipment can easily be deployed in the field, as it is a lightweight, low-cost system in comparison with classic aerial photo surveys and terrestrial or airborne LiDAR scanning. Four sets of aerial photographs were created for one test field. The sets of airphotos differ in focal length, and viewing angles, i.e. nadir view and ground-level view. In addition, the importance of the accuracy of ground control points for the construction of a georeferenced point cloud was assessed using two different GPS devices with horizontal accuracy at resp. the sub-meter and sub-decimeter level. Airphoto datasets were processed with SFM algorithm and the resulting point clouds were georeferenced. Then, the surface representations were compared with each other to assess the reproducibility of the earth surface topography. Finally, consistency between independent datasets is discussed.

  14. Extensible, Reusable, and Reproducible Computing: A Case Study of PySPH

    International Nuclear Information System (INIS)

    Ramachandran, Prabhu

    2016-01-01

    In this work, the Smoothed Particle Hydrodynamics (SPH) technique is considered as an example of a typical computational research area. PySPH is an open source framework for SPH computations. PySPH is designed to be easy to use. The framework allows a user to implement an entire simulation in pure Python. It is designed to make it easy for scientists to reuse their code and extend the work of others. These important features allow PySPH to facilitate reproducible computational research. Based on the experience with PySPH, general recommendations are suggested for other computational researchers. (paper)

  15. An efficient and reproducible method for improving growth of a soil alga (Chlorococcum infusionum) for toxicity assays.

    Science.gov (United States)

    Nam, Sun-Hwa; An, Youn-Joo

    2015-12-01

    This study evaluated five methods of soil inoculation using the soil alga Chlorococcum infusionum to determine the most efficient and reproducible method for promoting the growth of soil algae for toxicity testing. The five techniques included application of C. infusionum in a circle on top of the soil, to a central spot on top of the soil, to a central spot in the subsoil, to one side on top of the soil, and application divided between a circle and a central spot on top of the soil. Of these, the first method generated the greatest amount of chlorophyll fluorescence and was the method with the best reproducibility. We evaluated the applicability of this method in an assessment of the toxicity of copper and nickel to C. infusionum in two representative standard soils. Copper (20-75 mg/kg for OECD soil and 20-60 mg/kg Lufa 2.2 soil) and nickel (400-500 mg/kg for OECD soil and 60-100 mg/kg Lufa 2.2 soil) reduced the chlorophyll fluorescence of C. infusionum when the inoculation was delivered in a circle on top of both soil types. To our knowledge, this is the first study to assess the suitability of different soil algal inoculation methods for terrestrial toxicity testing. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Evaluation of the reproducibility of amplicon sequencing with Illumina MiSeq platform.

    Science.gov (United States)

    Wen, Chongqing; Wu, Liyou; Qin, Yujia; Van Nostrand, Joy D; Ning, Daliang; Sun, Bo; Xue, Kai; Liu, Feifei; Deng, Ye; Liang, Yuting; Zhou, Jizhong

    2017-01-01

    Illumina's MiSeq has become the dominant platform for gene amplicon sequencing in microbial ecology studies; however, various technical concerns, such as reproducibility, still exist. To assess reproducibility, 16S rRNA gene amplicons from 18 soil samples of a reciprocal transplantation experiment were sequenced on an Illumina MiSeq. The V4 region of 16S rRNA gene from each sample was sequenced in triplicate with each replicate having a unique barcode. The average OTU overlap, without considering sequence abundance, at a rarefaction level of 10,323 sequences was 33.4±2.1% and 20.2±1.7% between two and among three technical replicates, respectively. When OTU sequence abundance was considered, the average sequence abundance weighted OTU overlap was 85.6±1.6% and 81.2±2.1% for two and three replicates, respectively. Removing singletons significantly increased the overlap for both (~1-3%, pdeep sequencing increased OTU overlap both when sequence abundance was considered (95%) and when not (44%). However, if singletons were not removed the overlap between two technical replicates (not considering sequence abundance) plateaus at 39% with 30,000 sequences. Diversity measures were not affected by the low overlap as α-diversities were similar among technical replicates while β-diversities (Bray-Curtis) were much smaller among technical replicates than among treatment replicates (e.g., 0.269 vs. 0.374). Higher diversity coverage, but lower OTU overlap, was observed when replicates were sequenced in separate runs. Detrended correspondence analysis indicated that while there was considerable variation among technical replicates, the reproducibility was sufficient for detecting treatment effects for the samples examined. These results suggest that although there is variation among technical replicates, amplicon sequencing on MiSeq is useful for analyzing microbial community structure if used appropriately and with caution. For example, including technical replicates

  17. ITK: Enabling Reproducible Research and Open Science

    Directory of Open Access Journals (Sweden)

    Matthew Michael McCormick

    2014-02-01

    Full Text Available Reproducibility verification is essential to the practice of the scientific method. Researchers report their findings, which are strengthened as other independent groups in the scientific community share similar outcomes. In the many scientific fields where software has become a fundamental tool for capturing and analyzing data, this requirement of reproducibility implies that reliable and comprehensive software platforms and tools should be made available to the scientific community. The tools will empower them and the public to verify, through practice, the reproducibility of observations that are reported in the scientific literature.Medical image analysis is one of the fields in which the use of computational resources, both software and hardware, are an essential platform for performing experimental work. In this arena, the introduction of the Insight Toolkit (ITK in 1999 has transformed the field and facilitates its progress by accelerating the rate at which algorithmic implementations are developed, tested, disseminated and improved. By building on the efficiency and quality of open source methodologies, ITK has provided the medical image community with an effective platform on which to build a daily workflow that incorporates the true scientific practices of reproducibility verification.This article describes the multiple tools, methodologies, and practices that the ITK community has adopted, refined, and followed during the past decade, in order to become one of the research communities with the most modern reproducibility verification infrastructure. For example, 207 contributors have created over 2400 unit tests that provide over 84% code line test coverage. The Insight Journal, an open publication journal associated with the toolkit, has seen over 360,000 publication downloads. The median normalized closeness centrality, a measure of knowledge flow, resulting from the distributed peer code review system was high, 0.46.

  18. Static and Dynamic Handgrip Strength Endurance: Test-Retest Reproducibility.

    Science.gov (United States)

    Gerodimos, Vassilis; Karatrantou, Konstantina; Psychou, Dimitra; Vasilopoulou, Theodora; Zafeiridis, Andreas

    2017-03-01

    This study investigated the reliability of static and dynamic handgrip strength endurance using different protocols and indicators for the assessment of strength endurance. Forty young, healthy men and women (age, 18-22 years) performed 2 handgrip strength endurance protocols: a static protocol (sustained submaximal contraction at 50% of maximal voluntary contraction) and a dynamic one (8, 10, and 12 maximal repetitions). The participants executed each protocol twice to assess the test-retest reproducibility. Total work and total time were used as indicators of strength endurance in the static protocol; the strength recorded at each maximal repetition, the percentage change, and fatigue index were used as indicators of strength endurance in the dynamic protocol. The static protocol showed high reliability irrespective of sex and hand for total time and work. The 12-repetition dynamic protocol exhibited moderate-high reliability for repeated maximal repetitions and percentage change; the 8- and 10-repetition protocols demonstrated lower reliability irrespective of sex and hand. The fatigue index was not a reliable indicator for the assessment of dynamic handgrip endurance. Static handgrip endurance can be measured reliably using the total time and total work as indicators of strength endurance. For the evaluation of dynamic handgrip endurance, the 12-repetition protocol is recommended, using the repeated maximal repetitions and percentage change as indicators of strength endurance. Practitioners should consider the static (50% maximal voluntary contraction) and dynamic (12 repeated maximal repetitions) protocols as reliable for the assessment of handgrip strength endurance. The evaluation of static endurance in conjunction with dynamic endurance would provide more complete information about hand function. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. Empirical evaluation of cross-site reproducibility in radiomic features for characterizing prostate MRI

    Science.gov (United States)

    Chirra, Prathyush; Leo, Patrick; Yim, Michael; Bloch, B. Nicolas; Rastinehad, Ardeshir R.; Purysko, Andrei; Rosen, Mark; Madabhushi, Anant; Viswanath, Satish

    2018-02-01

    The recent advent of radiomics has enabled the development of prognostic and predictive tools which use routine imaging, but a key question that still remains is how reproducible these features may be across multiple sites and scanners. This is especially relevant in the context of MRI data, where signal intensity values lack tissue specific, quantitative meaning, as well as being dependent on acquisition parameters (magnetic field strength, image resolution, type of receiver coil). In this paper we present the first empirical study of the reproducibility of 5 different radiomic feature families in a multi-site setting; specifically, for characterizing prostate MRI appearance. Our cohort comprised 147 patient T2w MRI datasets from 4 different sites, all of which were first pre-processed to correct acquisition-related for artifacts such as bias field, differing voxel resolutions, as well as intensity drift (non-standardness). 406 3D voxel wise radiomic features were extracted and evaluated in a cross-site setting to determine how reproducible they were within a relatively homogeneous non-tumor tissue region; using 2 different measures of reproducibility: Multivariate Coefficient of Variation and Instability Score. Our results demonstrated that Haralick features were most reproducible between all 4 sites. By comparison, Laws features were among the least reproducible between sites, as well as performing highly variably across their entire parameter space. Similarly, the Gabor feature family demonstrated good cross-site reproducibility, but for certain parameter combinations alone. These trends indicate that despite extensive pre-processing, only a subset of radiomic features and associated parameters may be reproducible enough for use within radiomics-based machine learning classifier schemes.

  20. [DIN-compatible vision assessment of increased reproducibility using staircase measurement and maximum likelihood analysis].

    Science.gov (United States)

    Weigmann, U; Petersen, J

    1996-08-01

    Visual acuity determination according to DIN 58,220 does not make full use of the information received about the patient, in contrast to the staircase method. Thus, testing the same number of optotypes, the staircase method should yield more reproducible acuity results. On the other hand, the staircase method gives systematically higher acuity values because it converges on the 48% point of the psychometric function (for Landolt rings in eight positions) and not on the 65% probability, as DIN 58,220 with criterion 3/5 does. This bias can be avoided by means of a modified evaluation. Using the staircase data we performed a maximum likelihood estimate of the psychometric function as a whole and computed the acuity value for 65% probability of correct answers. We determined monocular visual acuity in 102 persons with widely differing visual performance. Each subject underwent four tests in random order, two according to DIN 58,220 and two using the modified staircase method (Landolt rings in eight positions scaled by a factor 1.26; PC monitor with 1024 x 768 pixels; distance 4.5 m). Each test was performed with 25 optotypes. The two procedures provide the same mean visual acuity values (difference less than 0.02 acuity steps). The test-retest results match in 30.4% of DIN repetitions but in 50% of the staircases. The standard deviation of the test-retest difference is 1.41 (DIN) and 1.06 (modified staircase) acuity steps. Thus the standard deviation of the single test is 1.0 (DIN) and 0.75 (modified staircase) acuity steps. The new method provides visual acuity values identical to DIN 58,220 but is superior with respect to reproducibility.

  1. Highly reproducible polyol synthesis for silver nanocubes

    Science.gov (United States)

    Han, Hye Ji; Yu, Taekyung; Kim, Woo-Sik; Im, Sang Hyuk

    2017-07-01

    We could synthesize the Ag nanocubes highly reproducibly by conducting the polyol synthesis using HCl etchant in dark condition because the photodecomposition/photoreduction of AgCl nanoparticles formed at initial reaction stage were greatly depressed and consequently the selective self-nucleation of Ag single crystals and their selective growth reaction could be promoted. Whereas the reproducibility of the formation of Ag nanocubes were very poor when we synthesize the Ag nanocubes in light condition due to the photoreduction of AgCl to Ag.

  2. Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

    International Nuclear Information System (INIS)

    Pittayapat, Pisha; Jacobs, Reinhilde; Odri, Guillaume A.; De Faria Vasconcelos, Karla; Willems, Guy; Olszewski, Raphael

    2015-01-01

    This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Thirty-two cone-beam computed tomographic scans (3D Accuitomo 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from 0.43±0.34 mm to 0.51±0.46 mm. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

  3. Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

    Energy Technology Data Exchange (ETDEWEB)

    Pittayapat, Pisha; Jacobs, Reinhilde [University Hospitals Leuven, University of Leuven, Leuven (Belgium); Odri, Guillaume A. [Service de Chirurgie Orthopedique et Traumatologique, Centre Hospitalier Regional d' Orleans, Orleans Cedex2 (France); De Faria Vasconcelos, Karla [Dept. of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Sao Paulo (Brazil); Willems, Guy [Dept. of Oral Health Sciences, Orthodontics, KU Leuven and Dentistry, University Hospitals Leuven, University of Leuven, Leuven (Belgium); Olszewski, Raphael [Dept. of Oral and Maxillofacial Surgery, Cliniques Universitaires Saint Luc, Universite Catholique de Louvain, Brussels (Belgium)

    2015-03-15

    This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Thirty-two cone-beam computed tomographic scans (3D Accuitomo 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from 0.43±0.34 mm to 0.51±0.46 mm. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

  4. Reproducible Bioinformatics Research for Biologists

    Science.gov (United States)

    This book chapter describes the current Big Data problem in Bioinformatics and the resulting issues with performing reproducible computational research. The core of the chapter provides guidelines and summaries of current tools/techniques that a noncomputational researcher would need to learn to pe...

  5. Reproducibility, controllability, and optimization of LENR experiments

    Energy Technology Data Exchange (ETDEWEB)

    Nagel, David J. [The George Washington University, Washington DC 20052 (United States)

    2006-07-01

    Low-energy nuclear reaction (LENR) measurements are significantly, and increasingly reproducible. Practical control of the production of energy or materials by LENR has yet to be demonstrated. Minimization of costly inputs and maximization of desired outputs of LENR remain for future developments. The paper concludes by underlying that it is now clearly that demands for reproducible experiments in the early years of LENR experiments were premature. In fact, one can argue that irreproducibility should be expected for early experiments in a complex new field. As emphasized in the paper and as often happened in the history of science, experimental and theoretical progress can take even decades. It is likely to be many years before investments in LENR experiments will yield significant returns, even for successful research programs. However, it is clearly that a fundamental understanding of the anomalous effects observed in numerous experiments will significantly increase reproducibility, improve controllability, enable optimization of processes, and accelerate the economic viability of LENR.

  6. Reproducibility, controllability, and optimization of LENR experiments

    International Nuclear Information System (INIS)

    Nagel, David J.

    2006-01-01

    Low-energy nuclear reaction (LENR) measurements are significantly, and increasingly reproducible. Practical control of the production of energy or materials by LENR has yet to be demonstrated. Minimization of costly inputs and maximization of desired outputs of LENR remain for future developments. The paper concludes by underlying that it is now clearly that demands for reproducible experiments in the early years of LENR experiments were premature. In fact, one can argue that irreproducibility should be expected for early experiments in a complex new field. As emphasized in the paper and as often happened in the history of science, experimental and theoretical progress can take even decades. It is likely to be many years before investments in LENR experiments will yield significant returns, even for successful research programs. However, it is clearly that a fundamental understanding of the anomalous effects observed in numerous experiments will significantly increase reproducibility, improve controllability, enable optimization of processes, and accelerate the economic viability of LENR

  7. Reproducibility of quantitative susceptibility mapping in the brain at two field strengths from two vendors.

    Science.gov (United States)

    Deh, Kofi; Nguyen, Thanh D; Eskreis-Winkler, Sarah; Prince, Martin R; Spincemaille, Pascal; Gauthier, Susan; Kovanlikaya, Ilhami; Zhang, Yan; Wang, Yi

    2015-12-01

    To assess the reproducibility of brain quantitative susceptibility mapping (QSM) in healthy subjects and in patients with multiple sclerosis (MS) on 1.5 and 3T scanners from two vendors. Ten healthy volunteers and 10 patients were scanned twice on a 3T scanner from one vendor. The healthy volunteers were also scanned on a 1.5T scanner from the same vendor and on a 3T scanner from a second vendor. Similar imaging parameters were used for all scans. QSM images were reconstructed using a recently developed nonlinear morphology-enabled dipole inversion (MEDI) algorithm with L1 regularization. Region-of-interest (ROI) measurements were obtained for 20 major brain structures. Reproducibility was evaluated with voxel-wise and ROI-based Bland-Altman plots and linear correlation analysis. ROI-based QSM measurements showed excellent correlation between all repeated scans (correlation coefficient R ≥ 0.97), with a mean difference of less than 1.24 ppb (healthy subjects) and 4.15 ppb (patients), and 95% limits of agreements of within -25.5 to 25.0 ppb (healthy subjects) and -35.8 to 27.6 ppb (patients). Voxel-based QSM measurements had a good correlation (0.64 ≤ R ≤ 0.88) and limits of agreements of -60 to 60 ppb or less. Brain QSM measurements have good interscanner and same-scanner reproducibility for healthy and MS subjects, respectively, on the systems evaluated in this study. © 2015 Wiley Periodicals, Inc.

  8. Transition questions in clinical practice - validity and reproducibility

    DEFF Research Database (Denmark)

    Lauridsen, Henrik Hein

    2008-01-01

    Transition questions in CLINICAL practice - validity and reproducibility Lauridsen HH1, Manniche C3, Grunnet-Nilsson N1, Hartvigsen J1,2 1   Clinical Locomotion Science, Institute of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark. e-mail: hlauridsen......@health.sdu.dk 2   Nordic Institute of Chiropractic and Clinical Biomechanics, Part of Clinical Locomotion Science, Odense, Denmark 3   Backcenter Funen, Part of Clinical Locomotion Science, Ringe, Denmark   Abstract  Understanding a change score is indispensable for interpretation of results from clinical studies...... are reproducible in patients with low back pain and/or leg pain. Despite critique of several biases, our results have reinforced the construct validity of TQ’s as an outcome measure since only 1 hypothesis was rejected. On the basis of our findings we have outlined a proposal for a standardised use of transition...

  9. The Effect of Bite Registration on the Reproducibility of Parallel Periapical Radiographs Obtained with Two Month Intervals

    Directory of Open Access Journals (Sweden)

    L. Khojastehpour

    2006-06-01

    Full Text Available Statement of Problem: Digital Subtraction Radiography (DSR needs reproducible alignment between the x-ray source, the object, and the film for obtaining identical projections of the same anatomic region.Purpose: The aim of this study was to evaluate the effect of bite registrations (placed on individual bite blocks on the reproducibility of parallel periapical radiographs,obtained every 2 months, in patients undergoing periodontal surgery for furcationinvolvement.Materials and Methods: Ninety eight parallel periapical radiographs were used in this study. The radiographs were taken with individual bite-blocks attached to the beamguiding device. In order to individualize the bite blocks, bite registrations were fabricated using silicon impression material, and were placed on the individual bite blocks. All radiographs in each series were processed under similar conditions and were digitized with the flatbed scanner fitted with a transparency adaptor (hp Scanjet 7400 at 300 dpi resolution. Reproducibility of this method for obtaining similar parallel periapical radiographs was assessed by measuring the horizontal and vertical distances between two selected unchanged reference points on each radiograph and comparing them in each series. Reliability of measurements was analyzed using the one wayrandom model intraclass correlation coefficient for average of raters.Results: For both measurements (Horizontal and Vertical statistically significant reliability was found between three repeated radiographs with two month intervals in 16 patients, as well as 5 repeated radiographs with two month intervals in 10 patients (P<0.001.Conclusion: The result of this study shows that bite registration on individual bite blocks is enough for obtaining identical parallel periapical radiographs.

  10. Reproducibility of myelin content-based human habenula segmentation at 3 Tesla.

    Science.gov (United States)

    Kim, Joo-Won; Naidich, Thomas P; Joseph, Joshmi; Nair, Divya; Glasser, Matthew F; O'halloran, Rafael; Doucet, Gaelle E; Lee, Won Hee; Krinsky, Hannah; Paulino, Alejandro; Glahn, David C; Anticevic, Alan; Frangou, Sophia; Xu, Junqian

    2018-03-26

    In vivo morphological study of the human habenula, a pair of small epithalamic nuclei adjacent to the dorsomedial thalamus, has recently gained significant interest for its role in reward and aversion processing. However, segmenting the habenula from in vivo magnetic resonance imaging (MRI) is challenging due to the habenula's small size and low anatomical contrast. Although manual and semi-automated habenula segmentation methods have been reported, the test-retest reproducibility of the segmented habenula volume and the consistency of the boundaries of habenula segmentation have not been investigated. In this study, we evaluated the intra- and inter-site reproducibility of in vivo human habenula segmentation from 3T MRI (0.7-0.8 mm isotropic resolution) using our previously proposed semi-automated myelin contrast-based method and its fully-automated version, as well as a previously published manual geometry-based method. The habenula segmentation using our semi-automated method showed consistent boundary definition (high Dice coefficient, low mean distance, and moderate Hausdorff distance) and reproducible volume measurement (low coefficient of variation). Furthermore, the habenula boundary in our semi-automated segmentation from 3T MRI agreed well with that in the manual segmentation from 7T MRI (0.5 mm isotropic resolution) of the same subjects. Overall, our proposed semi-automated habenula segmentation showed reliable and reproducible habenula localization, while its fully-automated version offers an efficient way for large sample analysis. © 2018 Wiley Periodicals, Inc.

  11. A technique for reproducible roentgenprograms of the intercondylar sulcus for the study of the femoropatellar

    International Nuclear Information System (INIS)

    Koelbel, R.; Bergmann, G.; Rohlmann, A.

    1979-01-01

    Roentgenographic documentation of certain features of FP-joint geometry and orientation may serve as guideline in deciding on the form of treatment for chondromalacia or recurrent patellar dislocation. Reproducible conditions for taking roentgen films are equally important for this purpose as well as for quantitative measurements and possible statistical work. A new positioning device for the patient's legs has been designed utilizing a parallellogram frame. The roentgenographic technique for skyline views at 30 0 , 60 0 and 90 0 inclination of the central beam relative to the femoral axis is described. The advantages over previous techniques are the ease of handling the positioning frame, the need for only vertical and horizontal adjustment of the roentgen tube, independence of the type of tube or table, reproducibility of cassette and patient positioning. (orig.) [de

  12. Online dietary intake estimation: reproducibility and validity of the Food4Me food frequency questionnaire against a 4-day weighed food record.

    Science.gov (United States)

    Fallaize, Rosalind; Forster, Hannah; Macready, Anna L; Walsh, Marianne C; Mathers, John C; Brennan, Lorraine; Gibney, Eileen R; Gibney, Michael J; Lovegrove, Julie A

    2014-08-11

    Advances in nutritional assessment are continuing to embrace developments in computer technology. The online Food4Me food frequency questionnaire (FFQ) was created as an electronic system for the collection of nutrient intake data. To ensure its accuracy in assessing both nutrient and food group intake, further validation against data obtained using a reliable, but independent, instrument and assessment of its reproducibility are required. The aim was to assess the reproducibility and validity of the Food4Me FFQ against a 4-day weighed food record (WFR). Reproducibility of the Food4Me FFQ was assessed using test-retest methodology by asking participants to complete the FFQ on 2 occasions 4 weeks apart. To assess the validity of the Food4Me FFQ against the 4-day WFR, half the participants were also asked to complete a 4-day WFR 1 week after the first administration of the Food4Me FFQ. Level of agreement between nutrient and food group intakes estimated by the repeated Food4Me FFQ and the Food4Me FFQ and 4-day WFR were evaluated using Bland-Altman methodology and classification into quartiles of daily intake. Crude unadjusted correlation coefficients were also calculated for nutrient and food group intakes. In total, 100 people participated in the assessment of reproducibility (mean age 32, SD 12 years), and 49 of these (mean age 27, SD 8 years) also took part in the assessment of validity. Crude unadjusted correlations for repeated Food4Me FFQ ranged from .65 (vitamin D) to .90 (alcohol). The mean cross-classification into "exact agreement plus adjacent" was 92% for both nutrient and food group intakes, and Bland-Altman plots showed good agreement for energy-adjusted macronutrient intakes. Agreement between the Food4Me FFQ and 4-day WFR varied, with crude unadjusted correlations ranging from .23 (vitamin D) to .65 (protein, % total energy) for nutrient intakes and .11 (soups, sauces and miscellaneous foods) to .73 (yogurts) for food group intake. The mean cross

  13. The reproducibility of the circadian BP rhythm in treated hypertensive patients with polycystic kidney disease and mild chronic renal impairment--a prospective ABPM study.

    Science.gov (United States)

    Covic, Adrian; Mititiuc, Irina; Gusbeth-Tatomir, Paul; Goldsmith, David J

    2002-01-01

    Diurnal BP rhythm is known to be abnormal (reduced BP fall with sleep) in chronic renal failure, dialysis and renal transplantation patients. In subjects with primary hypertension and with reduced diurnal BP fall with sleep there is consistent evidence of increased target-organ damage. However, the few studies that have addressed the reproducibility of diurnal rhythm in normal or hypertensive subjects have concluded that the BP fall with sleep is poorly reproducible. It is not known whether the same is true for patients with renal disease. In 30 subjects with autosomal polycystic kidney disease (ADPKD), mild chronic renal failure and normal office BP levels on standardised anti-hypertensive treatment, ambulatory blood pressure monitoring (ABPM) was done three times over a twelve month period to assess the reproducibility of blood pressure fall with sleep. When comparing ABPM 2 with the ABPM 1 recording (3 months difference between measurements) only 43.3% of the patients maintained the initial dipping category (defined by quartiles of the ABPM 1 diurnal BP distribution). The same proportion of subjects had a similar dipping category, when ABPM 3 was compared to ABPM 1 (9 months difference between measurements), but a large (24%) subset of patients had dramatic shifts in their amplitude in nocturnal BP fall, significantly greater than those recorded after a shorter inter-measurement interval. Equally important, our study reveals the fact that, with time, there is no tendency to decrease circadian variation: a similar proportion (a quarter to one third) of patients increased or decreased their amplitude in nocturnal BP fall, at 3 and 9 months. When several ABPM measurements are repeated for the same patients, the repeatability is even worse, since only 36.6% of our study population maintained the initial dipping category across all three ABPM determinations (ABPM 1 and ABPM 2 and ABPM 3). There is a widespread abnormality in diurnal BP rhythm in ADPKD patients with

  14. Reproducing Kernels and Coherent States on Julia Sets

    Energy Technology Data Exchange (ETDEWEB)

    Thirulogasanthar, K., E-mail: santhar@cs.concordia.ca; Krzyzak, A. [Concordia University, Department of Computer Science and Software Engineering (Canada)], E-mail: krzyzak@cs.concordia.ca; Honnouvo, G. [Concordia University, Department of Mathematics and Statistics (Canada)], E-mail: g_honnouvo@yahoo.fr

    2007-11-15

    We construct classes of coherent states on domains arising from dynamical systems. An orthonormal family of vectors associated to the generating transformation of a Julia set is found as a family of square integrable vectors, and, thereby, reproducing kernels and reproducing kernel Hilbert spaces are associated to Julia sets. We also present analogous results on domains arising from iterated function systems.

  15. Reproducing Kernels and Coherent States on Julia Sets

    International Nuclear Information System (INIS)

    Thirulogasanthar, K.; Krzyzak, A.; Honnouvo, G.

    2007-01-01

    We construct classes of coherent states on domains arising from dynamical systems. An orthonormal family of vectors associated to the generating transformation of a Julia set is found as a family of square integrable vectors, and, thereby, reproducing kernels and reproducing kernel Hilbert spaces are associated to Julia sets. We also present analogous results on domains arising from iterated function systems

  16. Bad Behavior: Improving Reproducibility in Behavior Testing.

    Science.gov (United States)

    Andrews, Anne M; Cheng, Xinyi; Altieri, Stefanie C; Yang, Hongyan

    2018-01-24

    Systems neuroscience research is increasingly possible through the use of integrated molecular and circuit-level analyses. These studies depend on the use of animal models and, in many cases, molecular and circuit-level analyses. Associated with genetic, pharmacologic, epigenetic, and other types of environmental manipulations. We illustrate typical pitfalls resulting from poor validation of behavior tests. We describe experimental designs and enumerate controls needed to improve reproducibility in investigating and reporting of behavioral phenotypes.

  17. A method to test the reproducibility and to improve performance of computer-aided detection schemes for digitized mammograms

    International Nuclear Information System (INIS)

    Zheng Bin; Gur, David; Good, Walter F.; Hardesty, Lara A.

    2004-01-01

    The purpose of this study is to develop a new method for assessment of the reproducibility of computer-aided detection (CAD) schemes for digitized mammograms and to evaluate the possibility of using the implemented approach for improving CAD performance. Two thousand digitized mammograms (representing 500 cases) with 300 depicted verified masses were selected in the study. Series of images were generated for each digitized image by resampling after a series of slight image rotations. A CAD scheme developed in our laboratory was applied to all images to detect suspicious mass regions. We evaluated the reproducibility of the scheme using the detection sensitivity and false-positive rates for the original and resampled images. We also explored the possibility of improving CAD performance using three methods of combining results from the original and resampled images, including simple grouping, averaging output scores, and averaging output scores after grouping. The CAD scheme generated a detection score (from 0 to 1) for each identified suspicious region. A region with a detection score >0.5 was considered as positive. The CAD scheme detected 238 masses (79.3% case-based sensitivity) and identified 1093 false-positive regions (average 0.55 per image) in the original image dataset. In eleven repeated tests using original and ten sets of rotated and resampled images, the scheme detected a maximum of 271 masses and identified as many as 2359 false-positive regions. Two hundred and eighteen masses (80.4%) and 618 false-positive regions (26.2%) were detected in all 11 sets of images. Combining detection results improved reproducibility and the overall CAD performance. In the range of an average false-positive detection rate between 0.5 and 1 per image, the sensitivity of the scheme could be increased approximately 5% after averaging the scores of the regions detected in at least four images. At low false-positive rate (e.g., ≤average 0.3 per image), the grouping method

  18. Validity and reproducibility of the Physical Activity Scale for the Elderly (PASE) questionnaire for the measurement of the physical activity level in patients after total knee arthroplasty.

    Science.gov (United States)

    Bolszak, Sylvain; Casartelli, Nicola C; Impellizzeri, Franco M; Maffiuletti, Nicola A

    2014-02-20

    The need for valid and reproducible questionnaires to routinely assess the physical activity level of patients after total knee arthroplasty (TKA) is of particular concern in clinical settings. Aims of this study were to evaluate the validity and reproducibility of the physical activity scale for the elderly (PASE) questionnaire in TKA patients, with a particular view on gender differences. A total of 50 elderly patients (25 women and 25 men aged 70 ± 6 years) following primary unilateral TKA were recruited. The reproducibility was evaluated by administering the PASE questionnaire during two occasions separated by 7 days. The construct (criterion) validity was investigated by comparing the physical activity level reported by patients in the PASE questionnaire to that measured by accelerometry. Reproducibility was evaluated using intraclass correlation coefficients (ICC3,1) for reliability and standard error of measurement (SEM) and smallest detectable change (SDC) for agreement, while validity was investigated with Pearson correlation coefficients. Reliability of the PASE total score was acceptable for men (ICC = 0.77) but not for women (ICC = 0.58). Its agreement was low for both men and women, as witnessed by high SEM (32% and 35%, respectively) and SDC (89% and 97%, respectively). Construct validity of the PASE total score was low in both men (r = 0.45) and women (r = 0.06). The PASE questionnaire has several validity and reproducibility shortcomings, therefore its use is not recommended for the assessment of physical activity level in patients after TKA, particularly in women.

  19. Inter-observer reproducibility in reporting on renal drainage in children with hydronephrosis: a large collaborative study

    International Nuclear Information System (INIS)

    Tondeur, Marianne; Piepsz, Amy; De Palma, Diego; Roca, Isabel; Ham, Hamphrey

    2008-01-01

    The goal of this study was to evaluate the inter-observer reproducibility in reporting on renal drainage obtained during 99m Tc MAG3 renography in children, when already processed data are offered to the observers. Because web site facilities were used for communication, 57 observers from five continents participated in the study. Twenty-three renograms, including furosemide stimulation and posterect postmicturition views, covering various patterns of drainage, were submitted to the observers. Images, curves and quantitative parameters were provided. Good or almost good drainage, partial drainage and poor or no drainage were the three possible responses for each kidney. An important bias was observed among the observers, some of them more systematically reporting the drainage as being good, while others had a general tendency to consider the drainage as poor. This resulted in rather poor inter-observer reproducibility, as for more than half of the kidneys, less than 80% of the observers agreed on one of the three responses. Analysis of the individual cases identified some obvious causes of discrepancy: the absence of a clear limit between partial and good or almost good drainage, the fact of including or neglecting the effect of micturition and change of patient's position, the underestimation of drainage in the case of a flat renographic curve, and the difficulties of interpretation in the case of a small, not well functioning kidney. There is an urgent need for better standardisation in estimating the quality of drainage. (orig.)

  20. Inter-observer reproducibility in reporting on renal drainage in children with hydronephrosis: a large collaborative study

    Energy Technology Data Exchange (ETDEWEB)

    Tondeur, Marianne; Piepsz, Amy [CHU Saint-Pierre, Departement des Radio-Isotopes, Brussels (Belgium); De Palma, Diego [Ospedale di Circolo, Nuclear Medicine, Varese (Italy); Roca, Isabel [Vall d' Hebron Hospital, Nuclear Medicine, Barcelona (Spain); Ham, Hamphrey [University Hospital, Department Nuclear Medicine, Ghent (Belgium)

    2008-03-15

    The goal of this study was to evaluate the inter-observer reproducibility in reporting on renal drainage obtained during {sup 99m}Tc MAG3 renography in children, when already processed data are offered to the observers. Because web site facilities were used for communication, 57 observers from five continents participated in the study. Twenty-three renograms, including furosemide stimulation and posterect postmicturition views, covering various patterns of drainage, were submitted to the observers. Images, curves and quantitative parameters were provided. Good or almost good drainage, partial drainage and poor or no drainage were the three possible responses for each kidney. An important bias was observed among the observers, some of them more systematically reporting the drainage as being good, while others had a general tendency to consider the drainage as poor. This resulted in rather poor inter-observer reproducibility, as for more than half of the kidneys, less than 80% of the observers agreed on one of the three responses. Analysis of the individual cases identified some obvious causes of discrepancy: the absence of a clear limit between partial and good or almost good drainage, the fact of including or neglecting the effect of micturition and change of patient's position, the underestimation of drainage in the case of a flat renographic curve, and the difficulties of interpretation in the case of a small, not well functioning kidney. There is an urgent need for better standardisation in estimating the quality of drainage. (orig.)

  1. Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices.

    Science.gov (United States)

    Braga, Lays Magalhães; Prado, Gustavo Faibischew; Umeda, Iracema Ioco Kikuchi; Kawauchi, Tatiana Satie; Taboada, Adriana Marques Fróes; Azevedo, Raymundo Soares; Pereira Filho, Horacio Gomes; Grupi, César José; Souza, Hayala Cristina Cavenague; Moreira, Dalmo Antônio Ribeiro; Nakagawa, Naomi Kondo

    2016-01-01

    Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86study showed good reproducibility of HRV at rest in two consecutive 6MW using Holter and PolarS810i. Additionally, PolarS810i produced good agreements in short-term HRV indices based on Holter simultaneous recordings at rest, during the 6MW and recovery in HF patients.

  2. Validity and Reproducibility of a Habitual Dietary Fibre Intake Short Food Frequency Questionnaire.

    Science.gov (United States)

    Healey, Genelle; Brough, Louise; Murphy, Rinki; Hedderley, Duncan; Butts, Chrissie; Coad, Jane

    2016-09-10

    Low dietary fibre intake has been associated with poorer health outcomes, therefore having the ability to be able to quickly assess an individual's dietary fibre intake would prove useful in clinical practice and for research purposes. Current dietary assessment methods such as food records and food frequency questionnaires are time-consuming and burdensome, and there are presently no published short dietary fibre intake questionnaires that can quantify an individual's total habitual dietary fibre intake and classify individuals as low, moderate or high habitual dietary fibre consumers. Therefore, we aimed to develop and validate a habitual dietary fibre intake short food frequency questionnaire (DFI-FFQ) which can quickly and accurately classify individuals based on their habitual dietary fibre intake. In this study the DFI-FFQ was validated against the Monash University comprehensive nutrition assessment questionnaire (CNAQ). Fifty-two healthy, normal weight male (n = 17) and female (n = 35) participants, aged between 21 and 61 years, completed the DFI-FFQ twice and the CNAQ once. All eligible participants completed the study, however the data from 46% of the participants were excluded from analysis secondary to misreporting. The DFI-FFQ cannot accurately quantify total habitual dietary fibre intakes, however, it is a quick, valid and reproducible tool in classifying individuals based on their habitual dietary fibre intakes.

  3. Effect of high image compression on the reproducibility of cardiac Sestamibi reporting

    International Nuclear Information System (INIS)

    Thomas, P.; Allen, L.; Beuzeville, S.

    1999-01-01

    Full text: Compression algorithms have been mooted to minimize storage space and transmission times of digital images. We assessed the impact of high-level lousy compression using JPEG and wavelet algorithms on image quality and reporting accuracy of cardiac Sestamibi studies. Twenty stress/rest Sestamibi cardiac perfusion studies were reconstructed into horizontal short, vertical long and horizontal long axis slices using conventional methods. Each of these six sets of slices were aligned for reporting and saved (uncompressed) as a bitmap. This bitmap was then compressed using JPEG compression, then decompressed and saved as a bitmap for later viewing. This process was repeated using the original bitmap and wavelet compression. Finally, a second copy of the original bitmap was made. All 80 bitmaps were randomly coded to ensure blind reporting. The bitmaps were read blinded and by consensus of 2 experienced nuclear medicine physicians using a 5-point scale and 25 cardiac segments. Subjective image quality was also reported using a 3-point scale. Samples of the compressed images were also subtracted from the original bitmap for visual comparison of differences. Results showed an average compression ratio of 23:1 for wavelet and 13:1 for JPEG. Image subtraction showed only very minor discordance between the original and compressed images. There was no significant difference in subjective quality between the compressed and uncompressed images. There was no significant difference in reporting reproducibility of the identical bitmap copy, the JPEG image and the wavelet image compared with the original bitmap. Use of the high compression algorithms described had no significant impact on reporting reproducibility and subjective image quality of cardiac Sestamibi perfusion studies

  4. Reproducible diagnosis of Chronic Lymphocytic Leukemia by flow cytometry

    DEFF Research Database (Denmark)

    Rawstron, Andy C; Kreuzer, Karl-Anton; Soosapilla, Asha

    2018-01-01

    The diagnostic criteria for CLL rely on morphology and immunophenotype. Current approaches have limitations affecting reproducibility and there is no consensus on the role of new markers. The aim of this project was to identify reproducible criteria and consensus on markers recommended for the di...

  5. Participant Nonnaiveté and the reproducibility of cognitive psychology

    NARCIS (Netherlands)

    R.A. Zwaan (Rolf); D. Pecher (Diane); G. Paolacci (Gabriele); S. Bouwmeester (Samantha); P.P.J.L. Verkoeijen (Peter); K. Dijkstra (Katinka); R. Zeelenberg (René)

    2017-01-01

    textabstractMany argue that there is a reproducibility crisis in psychology. We investigated nine well-known effects from the cognitive psychology literature—three each from the domains of perception/action, memory, and language, respectively—and found that they are highly reproducible. Not only can

  6. Repeatability and Reproducibility of Fibre-Based Nanogenerator Synthesized by Electrospinning Machine

    International Nuclear Information System (INIS)

    Suyitno; Huda, Sholiehul; Arifin, Zainal; Hadi, Syamsul; Lambang, Raymundus Lullus

    2014-01-01

    Zinc oxide fibres-based nanogenerators synthesized easily by electrospinning machine are promising to harvest electricity from mechanical energy. However, the repeatability and reproducibility were two major factors needed to be investigated to minimize product failure and to determine the feasibility of mass production of nanogenerators. The green fibres of zinc oxide were produced by electrospinning machine of zinc acetate and polyvinyl alcohol solution at a flow rate of 4 μL/min followed by sintering at temperature 550°C with heating rate 240°C/h. Each 10 nanogenerators was tested by three trained operators with three times of repetition at compressive load 0.5 kg. The nanogenerators revealed the maximum output voltage ranging from 203 to 217 mV. The value of repeatability and reproducibility of nanogenerators was approximately 24.29% showing that nanogenerators were still acceptable to be mass-produced. The relatively low reproducibility was mainly due to the operators, so that the checklist needed to be made easier and simpler for all the variables affecting to the quality of the fibres. Reducing the value of the repeatability and reproducibility is interesting to study further by creating a rotating collector so that the thickness and orientation of fibres can be arranged better

  7. Reproducibility Problems with the Abbott Laboratories LCx Assay for Chlamydia trachomatis and Neisseria gonorrhoeae

    OpenAIRE

    Gronowski, Ann M.; Copper, Susan; Baorto, David; Murray, Patrick R.

    2000-01-01

    This study demonstrates that significant reproducibility problems can occur during routine use of the Abbott Laboratories LCx assay for Chlamydia trachomatis and Neisseria gonorrhoeae. These problems can go undetected by the quality control procedures outlined in the manufacturer's package insert. We outline here procedures for detecting and preventing contamination and reproducibility problems.

  8. Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Cutajar, Marica; Hales, Patrick W.; Clark, Christopher A.; Gordon, Isky [UCL Institute of Child Health, Imaging and Biophysics Unit, London (United Kingdom); Thomas, David L. [UCL Institute of Neurology, Department of Brain Repair and Rehabilitation, London (United Kingdom); Banks, T. [Great Ormond Street Hospital, Department of Radiology, London (United Kingdom)

    2014-06-15

    To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF). Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods. The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min{sup -1} [100 ml tissue]{sup -1}, and using DCE MRI was 287 ± 70 ml min{sup -1} [100 ml tissue]{sup -1}. The group coefficient of variation (CV{sub g}) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CV{sub g}s of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement. The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques. (orig.)

  9. Esthetic Evaluation of Implant Crowns and Peri-Implant Soft Tissue in the Anterior Maxilla: Comparison and Reproducibility of Three Different Indices.

    Science.gov (United States)

    Tettamanti, Sandro; Millen, Christopher; Gavric, Jelena; Buser, Daniel; Belser, Urs C; Brägger, Urs; Wittneben, Julia-Gabriela

    2016-06-01

    A successful implant reconstruction with optimal esthetics consists of a visually pleasing prosthesis and complete and healthy surrounding soft tissue. In the current literature, numerous indices used to qualitatively assess esthetics have been described. However, studies comparing the indices and their reproducibility are scarce. The aim of this study was to compare three different esthetic indices for the evaluation of single implant-supported crowns. A total of 10 prosthodontists (P), 10 orthodontists (O), 10 general dentists (G), and 10 lay people (L) independently performed the same assessment using 30 photographs and corresponding casts with three different esthetic indices (Peri-Implant and Crown Index [PICI], Implant Crown Aesthetic Index [ICAI], "Pink Esthetic Score/White Esthetic Score [PES/WES]) and repeated the evaluations 4 weeks later. The PES/WES and the PICI showed significantly higher esthetic scores (pink, white, total) and clinical acceptance compared with the ICAI in all four groups and in both assessments. The highest intraobserver agreement was achieved using the PES/WES and the least with the ICAI. The mean Kappa per group ranged from 0.18 (group L with ICAI) to 0.63 (group G with PICI). In comparison with the ICAI, the PES/WES and PICI were more reproducible. Therefore, PES/WES and PICI seem to be more suitable as esthetic indices for single implant crowns. © 2015 Wiley Periodicals, Inc.

  10. A Framework for Reproducible Latent Fingerprint Enhancements.

    Science.gov (United States)

    Carasso, Alfred S

    2014-01-01

    Photoshop processing of latent fingerprints is the preferred methodology among law enforcement forensic experts, but that appproach is not fully reproducible and may lead to questionable enhancements. Alternative, independent, fully reproducible enhancements, using IDL Histogram Equalization and IDL Adaptive Histogram Equalization, can produce better-defined ridge structures, along with considerable background information. Applying a systematic slow motion smoothing procedure to such IDL enhancements, based on the rapid FFT solution of a Lévy stable fractional diffusion equation, can attenuate background detail while preserving ridge information. The resulting smoothed latent print enhancements are comparable to, but distinct from, forensic Photoshop images suitable for input into automated fingerprint identification systems, (AFIS). In addition, this progressive smoothing procedure can be reexamined by displaying the suite of progressively smoother IDL images. That suite can be stored, providing an audit trail that allows monitoring for possible loss of useful information, in transit to the user-selected optimal image. Such independent and fully reproducible enhancements provide a valuable frame of reference that may be helpful in informing, complementing, and possibly validating the forensic Photoshop methodology.

  11. Reproducibility of CT bone dosimetry: Operator versus automated ROI definition

    International Nuclear Information System (INIS)

    Louis, O.; Luypaert, R.; Osteaux, M.; Kalender, W.

    1988-01-01

    Intrasubject reproducibility with repeated determination of vertebral mineral density from a given set of CT images was investigated. The region of interest (ROI) in 10 patient scans was selected by four independent operators either manually or with an automated procedure separating cortical and spongeous bone, the operators being requested to interact in ROI selection. The mean intrasubject variation was found to be much lower with the automated process (0.3 to 0.6%) than with the conventional method (2.5 to 5.2%). In a second study, 10 patients were examined twice to determine the reproducibility of CT slice selection by the operator. The errors were of the same order of magnitude as in ROI selection. (orig.)

  12. CONNJUR R: an annotation strategy for fostering reproducibility in bio-NMR—protein spectral assignment

    Energy Technology Data Exchange (ETDEWEB)

    Fenwick, Matthew; Hoch, Jeffrey C. [UConn Health, Department of Molecular Biology and Biophysics (United States); Ulrich, Eldon [University of Wisconsin-Madison, Department of Biochemistry (United States); Gryk, Michael R., E-mail: gryk@uchc.edu [UConn Health, Department of Molecular Biology and Biophysics (United States)

    2015-10-15

    Reproducibility is a cornerstone of the scientific method, essential for validation of results by independent laboratories and the sine qua non of scientific progress. A key step toward reproducibility of biomolecular NMR studies was the establishment of public data repositories (PDB and BMRB). Nevertheless, bio-NMR studies routinely fall short of the requirement for reproducibility that all the data needed to reproduce the results are published. A key limitation is that considerable metadata goes unpublished, notably manual interventions that are typically applied during the assignment of multidimensional NMR spectra. A general solution to this problem has been elusive, in part because of the wide range of approaches and software packages employed in the analysis of protein NMR spectra. Here we describe an approach for capturing missing metadata during the assignment of protein NMR spectra that can be generalized to arbitrary workflows, different software packages, other biomolecules, or other stages of data analysis in bio-NMR. We also present extensions to the NMR-STAR data dictionary that enable machine archival and retrieval of the “missing” metadata.

  13. CONNJUR R: an annotation strategy for fostering reproducibility in bio-NMR—protein spectral assignment

    International Nuclear Information System (INIS)

    Fenwick, Matthew; Hoch, Jeffrey C.; Ulrich, Eldon; Gryk, Michael R.

    2015-01-01

    Reproducibility is a cornerstone of the scientific method, essential for validation of results by independent laboratories and the sine qua non of scientific progress. A key step toward reproducibility of biomolecular NMR studies was the establishment of public data repositories (PDB and BMRB). Nevertheless, bio-NMR studies routinely fall short of the requirement for reproducibility that all the data needed to reproduce the results are published. A key limitation is that considerable metadata goes unpublished, notably manual interventions that are typically applied during the assignment of multidimensional NMR spectra. A general solution to this problem has been elusive, in part because of the wide range of approaches and software packages employed in the analysis of protein NMR spectra. Here we describe an approach for capturing missing metadata during the assignment of protein NMR spectra that can be generalized to arbitrary workflows, different software packages, other biomolecules, or other stages of data analysis in bio-NMR. We also present extensions to the NMR-STAR data dictionary that enable machine archival and retrieval of the “missing” metadata

  14. Relative Validity and Reproducibility of a Food-Frequency Questionnaire for Estimating Food Intakes among Flemish Preschoolers

    Directory of Open Access Journals (Sweden)

    Inge Huybrechts

    2009-01-01

    Full Text Available The aims of this study were to assess the relative validity and reproducibility of a semi-quantitative food-frequency questionnaire (FFQ applied in a large region-wide survey among 2.5-6.5 year-old children for estimating food group intakes. Parents/guardians were used as a proxy. Estimated diet records (3d were used as reference method and reproducibility was measured by repeated FFQ administrations five weeks apart. In total 650 children were included in the validity analyses and 124 in the reproducibility analyses. Comparing median FFQ1 to FFQ2 intakes, almost all evaluated food groups showed median differences within a range of ± 15%. However, for median vegetables, fruit and cheese intake, FFQ1 was > 20% higher than FFQ2. For most foods a moderate correlation (0.5-0.7 was obtained between FFQ1 and FFQ2. For cheese, sugared drinks and fruit juice intakes correlations were even > 0.7. For median differences between the 3d EDR and the FFQ, six food groups (potatoes & grains; vegetables Fruit; cheese; meat, game, poultry and fish; and sugared drinks gave a difference > 20%. The largest corrected correlations (>0.6 were found for the intake of potatoes and grains, fruit, milk products, cheese, sugared drinks, and fruit juice, while the lowest correlations (<0.4 for bread and meat products. The proportion of subjects classified within one quartile (in the same/adjacent category by FFQ and EDR ranged from 67% (for meat products to 88% (for fruit juice. Extreme misclassification into the opposite quartiles was for all food groups < 10%. The results indicate that our newly developed FFQ gives reproducible estimates of food group intake. Overall, moderate levels of relative validity were observed for estimates of food group intake.

  15. Intra-rater reproducibility and validity of Nintendo Wii Balance Tests in community-dwelling Older Adults

    DEFF Research Database (Denmark)

    Jørgensen, Martin; Læssøe, Uffe; Hendriksen, C

    2014-01-01

    The aims of the current study were to examine the intrarater intersession reproducibility of the Nintendo Wii agility and stillness tests and explore the concurrent validity in relation to gold-standard force-plate analysis. Within-day intersession reproducibility was examined in 30 older adults ...

  16. Analytic performance studies and clinical reproducibility of a real-time PCR assay for the detection of epidermal growth factor receptor gene mutations in formalin-fixed paraffin-embedded tissue specimens of non-small cell lung cancer

    International Nuclear Information System (INIS)

    O’Donnell, Patrick; Shieh, Felice; Wei, Wen; Lawrence, H Jeffrey; Wu, Lin; Schilling, Robert; Bloom, Kenneth; Maltzman, Warren; Anderson, Steven; Soviero, Stephen; Ferguson, Jane; Shyu, Johnny; Current, Robert; Rehage, Taraneh; Tsai, Julie; Christensen, Mari; Tran, Ha Bich; Chien, Sean Shih-Chang

    2013-01-01

    Epidermal growth factor receptor (EGFR) gene mutations identify patients with non-small cell lung cancer (NSCLC) who have a high likelihood of benefiting from treatment with anti-EGFR tyrosine kinase inhibitors. Sanger sequencing is widely used for mutation detection but can be technically challenging, resulting in longer turn-around-time, with limited sensitivity for low levels of mutations. This manuscript details the technical performance verification studies and external clinical reproducibility studies of the cobas EGFR Mutation Test, a rapid multiplex real-time PCR assay designed to detect 41 mutations in exons 18, 19, 20 and 21. The assay’s limit of detection was determined using 25 formalin-fixed paraffin-embedded tissue (FFPET)-derived and plasmid DNA blends. Assay performance for a panel of 201 specimens was compared against Sanger sequencing with resolution of discordant specimens by quantitative massively parallel pyrosequencing (MPP). Internal and external reproducibility was assessed using specimens tested in duplicate by different operators, using different reagent lots, instruments and at different sites. The effects on the performance of the cobas EGFR test of endogenous substances and nine therapeutic drugs were evaluated in ten FFPET specimens. Other tests included an evaluation of the effects of necrosis, micro-organisms and homologous DNA sequences on assay performance, and the inclusivity of the assay for less frequent mutations. A >95% hit rate was obtained in blends with >5% mutant alleles, as determined by MPP analysis, at a total DNA input of 150 ng. The overall percent agreement between Sanger sequencing and the cobas test was 96.7% (negative percent agreement 97.5%; positive percent agreement 95.8%). Assay repeatability was 98% when tested with two operators, instruments, and reagent lots. In the external reproducibility study, the agreement was > 99% across all sites, all operators and all reagent lots for 11/12 tumors tested. Test

  17. Inter-examiner reproducibility of tests for lumbar motor control

    Directory of Open Access Journals (Sweden)

    Elkjaer Arne

    2011-05-01

    Full Text Available Abstract Background Many studies show a relation between reduced lumbar motor control (LMC and low back pain (LBP. However, test circumstances vary and during test performance, subjects may change position. In other words, the reliability - i.e. reproducibility and validity - of tests for LMC should be based on quantitative data. This has not been considered before. The aim was to analyse the reproducibility of five different quantitative tests for LMC commonly used in daily clinical practice. Methods The five tests for LMC were: repositioning (RPS, sitting forward lean (SFL, sitting knee extension (SKE, and bent knee fall out (BKFO, all measured in cm, and leg lowering (LL, measured in mm Hg. A total of 40 subjects (14 males, 26 females 25 with and 15 without LBP, with a mean age of 46.5 years (SD 14.8, were examined independently and in random order by two examiners on the same day. LBP subjects were recruited from three physiotherapy clinics with a connection to the clinic's gym or back-school. Non-LBP subjects were recruited from the clinic's staff acquaintances, and from patients without LBP. Results The means and standard deviations for each of the tests were 0.36 (0.27 cm for RPS, 1.01 (0.62 cm for SFL, 0.40 (0.29 cm for SKE, 1.07 (0.52 cm for BKFO, and 32.9 (7.1 mm Hg for LL. All five tests for LMC had reproducibility with the following ICCs: 0.90 for RPS, 0.96 for SFL, 0.96 for SKE, 0.94 for BKFO, and 0.98 for LL. Bland and Altman plots showed that most of the differences between examiners A and B were less than 0.20 cm. Conclusion These five tests for LMC displayed excellent reproducibility. However, the diagnostic accuracy of these tests needs to be addressed in larger cohorts of subjects, establishing values for the normal population. Also cut-points between subjects with and without LBP must be determined, taking into account age, level of activity, degree of impairment and participation in sports. Whether reproducibility of these

  18. Regulating Ultrasound Cavitation in order to Induce Reproducible Sonoporation

    Science.gov (United States)

    Mestas, J.-L.; Alberti, L.; El Maalouf, J.; Béra, J.-C.; Gilles, B.

    2010-03-01

    Sonoporation would be linked to cavitation, which generally appears to be a non reproducible and unstationary phenomenon. In order to obtain an acceptable trade-off between cell mortality and transfection, a regulated cavitation generator based on an acoustical cavitation measurement was developed and tested. The medium to be sonicated is placed in a sample tray. This tray is immersed in in degassed water and positioned above the face of a flat ultrasonic transducer (frequency: 445 kHz; intensity range: 0.08-1.09 W/cm2). This technical configuration was admitted to be conducive to standing-wave generation through reflection at the air/medium interface in the well thus enhancing the cavitation phenomenon. Laterally to the transducer, a homemade hydrophone was oriented to receive the acoustical signal from the bubbles. From this spectral signal recorded at intervals of 5 ms, a cavitation index was calculated as the mean of the cavitation spectrum integration in a logarithmic scale, and the excitation power is automatically corrected. The device generates stable and reproducible cavitation level for a wide range of cavitation setpoint from stable cavitation condition up to full-developed inertial cavitation. For the ultrasound intensity range used, the time delay of the response is lower than 200 ms. The cavitation regulation device was evaluated in terms of chemical bubble collapse effect. Hydroxyl radical production was measured on terephthalic acid solutions. In open loop, the results present a great variability whatever the excitation power. On the contrary the closed loop allows a great reproducibility. This device was implemented for study of sonodynamic effect. The regulation provides more reproducible results independent of cell medium and experimental conditions (temperature, pressure). Other applications of this regulated cavitation device concern internalization of different particles (Quantum Dot) molecules (SiRNA) or plasmids (GFP, DsRed) into different

  19. Using peers to assess handoffs: a pilot study.

    Science.gov (United States)

    Dine, C Jessica; Wingate, Nicholas; Rosen, Ilene M; Myers, Jennifer S; Lapin, Jennifer; Kogan, Jennifer R; Shea, Judy A

    2013-08-01

    Handoffs among post-graduate year 1 (PGY1) trainees occur with high frequency. Peer assessment of handoff competence would add a new perspective on how well the handoff information helped them to provide optimal patient care. The goals of this study were to test the feasibility of the approach of an instrument for peer assessment of handoffs by meeting criteria of being able to use technology to capture evaluations in real time, exhibiting strong psychometric properties, and having high PGY1 satisfaction scores. An iPad® application was built for a seven-item handoff instrument. Over a two-month period, post-call PGY1s completed assessments of three co-PGY1s from whom they received handoffs the prior evening. Internal Medicine PGY1s at the University of Pennsylvania. ANOVA was used to explore interperson score differences (validity). Generalizability analyses provided estimates of score precision (reproducibility). PGY1s completed satisfaction surveys about the process. Sixty-two PGY1s (100 %) participated in the study. 59 % of the targeted evaluations were completed. The major limitations were network connectivity and inability to find the post-call trainee. PGY1 scores on the single item of "overall competency" ranged from 4 to 9 with a mean of 7.31 (SD 1.09). Generalizability coefficients approached 0.60 for 10 evaluations per PGY1 for a single rotation and 12 evaluations per PGY1 across multiple rotations. The majority of PGY1s believed that they could adequately assess handoff competence and that the peer assessment process was valuable (70 and 77 %, respectively). Psychometric properties of an instrument for peer assessment of handoffs are encouraging. Obtaining 10 or 12 evaluations per PGY1 allowed for reliable assessment of handoff skills. Peer evaluations of handoffs using mobile technology were feasible, and were well received by PGY1s.

  20. Reproducibility of “The bethesda system for reporting thyroid cytopathology:” A retrospective analysis of 107 patients

    Directory of Open Access Journals (Sweden)

    Pragati Awasthi

    2018-01-01

    Full Text Available Objectives: Fine-needle aspiration cytology (FNAC has emerged as an indispensable tool to discriminate thyroid lesions into benign or malignant for appropriate management. The need for simplicity of communication and standardization of terminology for thyroid FNAC reporting led to introduction of “The Bethesda system for reporting Thyroid Cytopathology” (TBSRTC in a conference held at the National Cancer Institute in 2007. This study aims at establishing the reproducibility of TBSRTC for diagnosing thyroid lesions. Materials and Methods: The present study comprised thyroid FNAC from 107 patients retrospectively over a period of 1.5 year (June 2013 to December 2014, which were reviewed by two trained cytopathologists and re-categorized according to TBSRTC. The interobserver variation and reproducibility of the reporting system was statistically assessed using Cohen's kappa. Results: The cytopathologists were in agreement in 98 out of 107 cases (91.5%. Maximum concordance was noted in benign category (91 of 96 cases; 92.85%, followed by 2 cases each in nondiagnostic/unsatisfactory (ND/US and follicular neoplasm/suspicious for follicular neoplasm (FN/SFN category (2.04% each and 1 case each in atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS, suspicious for malignancy (SUS, and malignant category (1.02% each. The highest diagnostic disagreement was noted among ND/US and benign and benign and FN/SFN categories. Conclusion: The utilization of TBSRTC for reporting thyroid cytology should be promoted in our country because it provides a homogeneous, standardized, and unanimous terminology for cytological diagnosis of thyroid lesions. The present study could substantiate the diagnostic reproducibility of this system.

  1. Reproducibility of Mammography Units, Film Processing and Quality Imaging

    International Nuclear Information System (INIS)

    Gaona, Enrique

    2003-01-01

    The purpose of this study was to carry out an exploratory survey of the problems of quality control in mammography and processors units as a diagnosis of the current situation of mammography facilities. Measurements of reproducibility, optical density, optical difference and gamma index are included. Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is a radiographic examination specially designed for detecting breast pathology. We found that the problems of reproducibility of AEC are smaller than the problems of processors units because almost all processors fall outside of the acceptable variation limits and they can affect the mammography quality image and the dose to breast. Only four mammography units agree with the minimum score established by ACR and FDA for the phantom image

  2. Design of reproducible polarized and non-polarized edge filters using genetic algorithm

    International Nuclear Information System (INIS)

    Ejigu, Efrem Kebede; Lacquet, B M

    2010-01-01

    Recent advancement in optical fibre communications technology is partly due to the advancement of optical thin film technology. The advancement of optical thin film technology includes the development of new and existing optical filter design methods. The genetic algorithm is one of the new design methods that show promising results in designing a number of complicated design specifications. It is the finding of this study that the genetic algorithm design method, through its optimization capability, can give more reliable and reproducible designs of any specifications. The design method in this study optimizes the thickness of each layer to get to the best possible solution. Its capability and unavoidable limitations in designing polarized and non-polarized edge filters from absorptive and dispersive materials is well demonstrated. It is also demonstrated that polarized and non-polarized designs from the genetic algorithm are reproducible with great success. This research has accomplished the great task of formulating a computer program using the genetic algorithm in a Matlab environment for the design of a reproducible polarized and non-polarized filters of any sort from any kind of materials

  3. Reproducible and controllable induction voltage adder for scaled beam experiments

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Yasuo; Nakajima, Mitsuo; Horioka, Kazuhiko [Department of Energy Sciences, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-8502 (Japan)

    2016-08-15

    A reproducible and controllable induction adder was developed using solid-state switching devices and Finemet cores for scaled beam compression experiments. A gate controlled MOSFET circuit was developed for the controllable voltage driver. The MOSFET circuit drove the induction adder at low magnetization levels of the cores which enabled us to form reproducible modulation voltages with jitter less than 0.3 ns. Preliminary beam compression experiments indicated that the induction adder can improve the reproducibility of modulation voltages and advance the beam physics experiments.

  4. Interpretative intra- and interobserver reproducibility of Stress/Rest 99m Tc-steamboat's myocardial perfusion SPECT using semi quantitative 20-segment model

    International Nuclear Information System (INIS)

    Fazeli, M.; Firoozi, F.

    2002-01-01

    It well established that myocardial perfusion SPECT with 201 T L or 99 mTc-se sta mi bi play an important role diagnosis and risk assessment in patients with known or suspected coronary artery disease. Both quantitative and qualitative methods are available for interpretation of images. The use of a semi quantitative scoring system in which each of 20 segments is scored according to a five-point scheme provides an approach to interpretation that is more systematic and reproducible than simple qualitative evaluation. Only a limited number of studies have dealt with the interpretive observer reproducibility of 99 mTc-steamboat's myocardial perfusion imaging. The aim of this study was to assess the intra-and inter observer variability of semi quantitative SPECT performed with this technique. Among 789 patients that underwent myocardial perfusion SPECT during last year 80 patients finally need to coronary angiography as gold standard. In this group of patients a semi quantitative visual interpretation was carried out using short axis and vertical long-axis myocardial tomograms and a 20-segments model. These segments we reassigned on six evenly spaced regions in the apical, mid-ventricular, and basal short-axis view and two apical segments on the mid-ventricular long-axis slice. Uptake in each segment was graded on a 5-point scale (0=normal, 1=equivocal, 2=moderate, 3=severe, 4=absence of uptake). The steamboat's images was interpreted separately w ice by two observers without knowledge of each other's findings or results of angiography. A SPECT study was judged abnormal if there were two or more segments with a stress score equal or more than 2. We con eluded that semi-quantitative visual analysis is a simple and reproducible method of interpretation

  5. Reproducibility of an automatic quantitation of regional myocardial wall motion and systolic thickening on gated Tc-99m-MIBI myocardial SPECT

    International Nuclear Information System (INIS)

    Paeng, Jin Chul; Lee, Dong Soo; Cheon, Gi Jeong; Kim, Yu Kyeong; Chung, June Key; Lee, Myung Chul

    2000-01-01

    The aim of this study is to investigate the reproducibility of the quantitative assessment of segmental wall motion and systolic thickening provided by an automatic quantitation algorithm. Tc-99m-MIBI gated myocardial SPECT with dipyridamole stress was performed in 31 patients with known or suspected coronary artery disease (4 with single, 6 with two, 11 with triple vessel disease; ejection fraction 51±14%) twice consecutively in the same position. Myocardium was divided into 20 segments. Segmental wall motion and systolic thickening were calculated and expressed in mm and % increase respectively, using AutoQUANT TM software. The reproducibility of this quantitative measurement of wall motion and thickening was tested. Correlations between repeated measurements on consecutive gated SPECT were excellent for wall motion (r=0.95) and systolic thickening (r=0.88). On Bland-Altman analysis, two standard deviation was 2 mm for repeated measurement of segmental wall motion, and 20% for that of systolic thickening. The weighted kappa values of repeated measurements were 0.807 for wall motion and 0.708 for systolic thickening. Sex, perfusion, or segmental location had no influence on reproducibility. Segmental wall motion and systolic thickening quantified using AutoQUANT TM software on gated myocardial SPECT offers good reproducibility and is significantly different when the change is more than 2 mm for wall motion and more than 20% for systolic thickening

  6. The Dutch motor skills assessment as tool for talent development in table tennis : a reproducibility and validity study

    NARCIS (Netherlands)

    Faber, Irene R.; Nijhuis-Van der Sanden, Maria W. G.; Elferink-Gemser, Marije T.; Oosterveld, Frits G. J.

    2015-01-01

    A motor skills assessment could be helpful in talent development by estimating essential perceptuo-motor skills of young players, which are considered requisite to develop excellent technical and tactical qualities. The Netherlands Table Tennis Association uses a motor skills assessment in their

  7. The Dutch motor skills assessment as tool for talent development in table tennis: a reproducibility and validity study

    NARCIS (Netherlands)

    Faber, I.R.; Nijhuis-Van der Sanden, M.W.G.; Elferink-Gemser, M.T.; Oosterveld, F.G.

    2015-01-01

    A motor skills assessment could be helpful in talent development by estimating essential perceptuo-motor skills of young players, which are considered requisite to develop excellent technical and tactical qualities. The Netherlands Table Tennis Association uses a motor skills assessment in their

  8. The Dutch motor skills assessment as tool for talent development in table tennis: a reproducibility and validity study

    NARCIS (Netherlands)

    Faber, I.R.; Nijhuis-Van der Sanden, M.W.; Elferink-Gemser, M.T.; Oosterveld, F.G.J.

    2014-01-01

    Abstract A motor skills assessment could be helpful in talent development by estimating essential perceptuo-motor skills of young players, which are considered requisite to develop excellent technical and tactical qualities. The Netherlands Table Tennis Association uses a motor skills assessment in

  9. GeoTrust Hub: A Platform For Sharing And Reproducing Geoscience Applications

    Science.gov (United States)

    Malik, T.; Tarboton, D. G.; Goodall, J. L.; Choi, E.; Bhatt, A.; Peckham, S. D.; Foster, I.; Ton That, D. H.; Essawy, B.; Yuan, Z.; Dash, P. K.; Fils, G.; Gan, T.; Fadugba, O. I.; Saxena, A.; Valentic, T. A.

    2017-12-01

    Recent requirements of scholarly communication emphasize the reproducibility of scientific claims. Text-based research papers are considered poor mediums to establish reproducibility. Papers must be accompanied by "research objects", aggregation of digital artifacts that together with the paper provide an authoritative record of a piece of research. We will present GeoTrust Hub (http://geotrusthub.org), a platform for creating, sharing, and reproducing reusable research objects. GeoTrust Hub provides tools for scientists to create `geounits'--reusable research objects. Geounits are self-contained, annotated, and versioned containers that describe and package computational experiments in an efficient and light-weight manner. Geounits can be shared on public repositories such as HydroShare and FigShare, and also using their respective APIs reproduced on provisioned clouds. The latter feature enables science applications to have a lifetime beyond sharing, wherein they can be independently verified and trust be established as they are repeatedly reused. Through research use cases from several geoscience laboratories across the United States, we will demonstrate how tools provided from GeoTrust Hub along with Hydroshare as its public repository for geounits is advancing the state of reproducible research in the geosciences. For each use case, we will address different computational reproducibility requirements. Our first use case will be an example of setup reproducibility which enables a scientist to set up and reproduce an output from a model with complex configuration and development environments. Our second use case will be an example of algorithm/data reproducibility, where in a shared data science model/dataset can be substituted with an alternate one to verify model output results, and finally an example of interactive reproducibility, in which an experiment is dependent on specific versions of data to produce the result. Toward this we will use software and data

  10. Reproducibility of kinematic measures of the thoracic spine, lumbar spine and pelvis during fast running.

    Science.gov (United States)

    Mason, D L; Preece, S J; Bramah, C A; Herrington, L C

    2016-01-01

    This study evaluated the reproducibility of the angular rotations of the thoracic spine, lumbar spine, pelvis and lower extremity during running. In addition, the study compared kinematic reproducibility between two methods for calculating kinematic trajectories: a six degrees of freedom (6DOF) approach and a global optimisation (GO) approach. With the first approach segments were treated independently, however with GO approach joint constraints were imposed to stop translation of adjacent segments. A total of 12 athletes were tested on two separate days whilst running over ground at a speed of 5.6ms(-1). The results demonstrated good between-day reproducibility for most kinematic parameters in the frontal and transverse planes with typical angular errors of 1.4-3°. Acceptable repeatability was also found in the sagittal plane. However, in this plane, although kinematic waveform shape was preserved between testing session, there were sometimes shifts in curve offset which lead to slightly higher angular errors, typically ranging from 1.9° to 3.5°. In general, the results demonstrated similar levels of reproducibility for both computational approaches (6DOF and, GO) and therefore suggest that GO may not lead to improved kinematic reproducibility during running. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Is liver perfusion CT reproducible? A study on intra- and interobserver agreement of normal hepatic haemodynamic parameters obtained with two different software packages.

    Science.gov (United States)

    Bretas, Elisa Almeida Sathler; Torres, Ulysses S; Torres, Lucas Rios; Bekhor, Daniel; Saito Filho, Celso Fernando; Racy, Douglas Jorge; Faggioni, Lorenzo; D'Ippolito, Giuseppe

    2017-10-01

    To evaluate the agreement between the measurements of perfusion CT parameters in normal livers by using two different software packages. This retrospective study was based on 78 liver perfusion CT examinations acquired for detecting suspected liver metastasis. Patients with any morphological or functional hepatic abnormalities were excluded. The final analysis included 37 patients (59.7 ± 14.9 y). Two readers (1 and 2) independently measured perfusion parameters using different software packages from two major manufacturers (A and B). Arterial perfusion (AP) and portal perfusion (PP) were determined using the dual-input vascular one-compartmental model. Inter-reader agreement for each package and intrareader agreement between both packages were assessed with intraclass correlation coefficients (ICC) and Bland-Altman statistics. Inter-reader agreement was substantial for AP using software A (ICC = 0.82) and B (ICC = 0.85-0.86), fair for PP using software A (ICC = 0.44) and fair to moderate for PP using software B (ICC = 0.56-0.77). Intrareader agreement between software A and B ranged from slight to moderate (ICC = 0.32-0.62) for readers 1 and 2 considering the AP parameters, and from fair to moderate (ICC = 0.40-0.69) for readers 1 and 2 considering the PP parameters. At best there was only moderate agreement between both software packages, resulting in some uncertainty and suboptimal reproducibility. Advances in knowledge: Software-dependent factors may contribute to variance in perfusion measurements, demanding further technical improvements. AP measurements seem to be the most reproducible parameter to be adopted when evaluating liver perfusion CT.

  12. Reproducibility of the chamber scarification test

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner

    1996-01-01

    The chamber scarification test is a predictive human skin irritation test developed to rank the irritation potential of products and ingredients meant for repeated use on normal and diseased skin. 12 products or ingredients can be tested simultaneously on the forearm skin of each volunteer....... The test combines with the procedure scratching of the skin at each test site and subsequent closed patch tests with the products, repeated daily for 3 days. The test is performed on groups of human volunteers: a skin irritant substance or products is included in each test as a positive control...... high reproducibility of the test. Further, intra-individual variation in skin reaction to the 2 control products in 26 volunteers, who participated 2x, is shown, which supports the conclusion that the chamber scarification test is a useful short-term human skin irritation test with high reproducibility....

  13. Computed tomography-based lung nodule volumetry - do optimized reconstructions of routine protocols achieve similar accuracy, reproducibility and interobserver variability to that of special volumetry protocols?

    International Nuclear Information System (INIS)

    Bolte, H.; Riedel, C.; Knoess, N.; Hoffmann, B.; Heller, M.; Biederer, J.; Freitag, S.

    2007-01-01

    Purpose: The aim of this in vitro and ex vivo CT study was to investigate whether the use of a routine thorax protocol (RTP) with optimized reconstruction parameters can provide comparable accuracy, reproducibility and interobserver variability of volumetric analyses to that of a special volumetry protocol (SVP). Materials and Methods: To assess accuracy, 3 polyurethane (PU) spheres (35 HU; diameters: 4, 6 and 10 mm) were examined with a recommended SVP using a multislice CT (collimation 16 x 0.75 mm, pitch 1.25, 20 mAs, slice thickness 1 mm, increment 0.7 mm, medium kernel) and an optimized RTP (collimation 16 x 1.5 mm, pitch 1.25, 100 mAs, reconstructed slice thickness 2 mm, increment 0.4 mm, sharp kernel). For the assessment of intrascan and interscan reproducibility and interobserver variability, 20 artificial small pulmonary nodules were placed in a dedicated ex vivo chest phantom and examined with identical scan protocols. The artificial lesions consisted of a fat-wax-Lipiodol registered mixture. Phantoms and ex vivo lesions were examined afterwards using commercial volumetry software. To describe accuracy the relative deviations from the true volumes of the PU phantoms were calculated. For intrascan and interscan reproducibility and interobserver variability, the 95 % normal range (95 % NR) of relative deviations between two measurements was calculated. Results: For the SVP the achieved relative deviations for the 4, 6 and 10 mm PU phantoms were - 14.3 %, - 12.7 % and - 6.8 % and were 4.5 %, - 0.6 % and - 2.6 %, respectively, for the optimized RTP. SVP showed a 95 % NR of 0 - 1.5 % for intrascan and a 95 % NR of - 10.8 - 2.9 % for interscan reproducibility. The 95 % NR for interobserver variability was - 4.3 - 3.3 %. The optimized RTP achieved a 95 % NR of - 3.1 - 4.3 % for intrascan reproducibility and a 95 % NR of - 7.0 - 3.5 % for interscan reproducibility. The 95 % NR for interobserver variability was - 0.4 - 6.8 %. (orig.)

  14. Evaluation of normality and reproducibility parameters of scintigraphy with (99m)Tc-MAA in the diagnosis of intrapulmonary vascular dilatations.

    Science.gov (United States)

    de Queirós, Andréa Simone Siqueira; Brandão, Simone Cristina Soares; Macedo, Liana Gonçalves; Ourem, Maira Souto; Mota, Vitor Gomes; Leite, Luiz Arthur Calheiros; Lopes, Edmundo Pessoa Almeida; Domingues, Ana Lúcia Coutinho

    2015-01-01

    The formation of intrapulmonary vascular dilations (IPVD) is the key event for the onset of hepatopulmonary syndrome, vascular changes secondary to portal hypertension that leads to hypoxemia. The diagnosis of IPVD can be made by contrasted transthoracic echocardiography or scintigraphy with technetium-macroaggregated albumin-((99m)Tc-MAA)-that is a sensitive and specific diagnostic method and quantifies the IPVD magnitude. However, its procedure and diagnostic indices are not yet standardized and well defined in health services. The aims of this study were to define normality values and evaluate the inter- and intra-observer reproducibility degree of diagnostic indexes of IPVD through (99m)Tc-MAA scintigraphy. Cross-sectional study was conducted at the Clinical Hospital, Federal University of Pernambuco (HC-UFPE) between July and December 2012. Fifteen patients with hepatosplenic schistosomiasis and nine patients without liver or heart disease (control group) were assessed. After clinical assessment, ultrasound and echocardiography, patients underwent (99m)Tc-MAA scintigraphy, and a relative brain uptake value exceeding 6 % or systemic uptake value exceeding 11 % was considered diagnostic of IPVD. Each assessment was performed by two independent observers. To analyze the results of the normal group, the nonparametric Bootsptrap method simulation model combined with the Monte Carlo method was used and to analyze inter- and intra-observer reproducibility indexes, the kappa and intra-class correlation coefficient were used. In normal subjects, the average brain uptake of (99m)Tc-MAA was 7.9 ± 0.01 % and systemic uptake was 12.4 ± 0.03 %, with low dispersal rates for both measures. The intra-observer agreement was 100 %, with kappa index of 1.0 (p brain uptake; however, systemic uptake showed kappa = 0.25 (p = 0.07), which features tolerable concordance. The intra-class correlation was excellent for both uptake indexes. The normality values were

  15. Reproducibility and relative validity of a food-frequency questionnaire for French-speaking Swiss adults

    Directory of Open Access Journals (Sweden)

    Pedro Marques-Vidal

    2011-05-01

    Full Text Available Background : Due to the distinct cultural and language differences that exist in Switzerland, there is little information on the dietary intake among the general Swiss population. Adequately assessing dietary intake is thus paramount if nutritional epidemiological studies are to be conducted. Objective : To assess the reproducibility and validity of a food-frequency questionnaire (FFQ developed for French-speaking Swiss adults. Design : A total of 23 men and 17 women (43.1±2.0 years filled out one FFQ and completed one 24-hour dietary recall at baseline and 1 month afterward. Results : Crude Pearson's correlation coefficients between the first and the second FFQ ranged from 0.58 to 0.90, intraclass correlation coefficient (ICC ranged between 0.53 and 0.92. Lin's concordance coefficients ranged between 0.55 and 0.87. Over 80% of participants were classified in the same or adjacent tertile using each FFQ. Macronutrient intakes estimated by both FFQs were significantly higher than those estimated from the 24-hour recall for protein and water, while no significant differences were found for energy, carbohydrate, fats (five groups, and alcohol. De-attenuated Pearson's correlation coefficients between the 24-hour recall and the first FFQ ranged between 0.31 and 0.49, while for the second FFQ the values ranged between 0.38 and 0.59. Over 40 and 95% of participants fell into the same or the adjacent energy and nutrient tertiles, respectively, using the FFQs and the 24-hour recall. Conclusions : This FFQ shows good reproducibility and can be used determining macronutrient intake in a French-speaking Swiss population in an epidemiological setting.

  16. Chronic medical conditions and reproducibility of self-reported age at menopause among community-dwelling women.

    Science.gov (United States)

    de Vries, Heather F; Northington, Gina M; Kaye, Elise M; Bogner, Hillary R

    2011-12-01

    The aim of this study was to examine the association between chronic medical conditions and reproducibility of self-reported age at menopause among community-dwelling women. Age at menopause was assessed in a population-based longitudinal survey of 240 women twice, in 1993 and 2004. Women who recalled age at menopause in 2004 within 1 year or less of age at menopause recalled in 1993 (concordant) were compared with women who did not recall age at menopause in 2004 within 1 year of age at menopause recalled in 1993 (discordant). Type of menopause (surgical or natural) and chronic medical conditions were assessed by self-report. One hundred forty-three women (59.6%) reported surgical menopause, and 97 (40.4%) reported natural menopause. In all, 130 (54.2%) women recalled age at menopause in 2004 within 1 year or less of recalled age at menopause in 1994, whereas 110 (45.8%) women did not recall age at menopause in 2004 within 1 year or less of recalled age at menopause in 1994. Among the women with surgical menopause, the women with three or more medical conditions were less likely to have concordant recall of age at menopause than the women with less than three chronic medical conditions (adjusted odds ratio, 0.36; 95% CI, 0.15-0.91) in multivariate models controlling for potentially influential characteristics including cognition and years since menopause. Among women who underwent surgical menopause, the presence of three or more medical conditions is associated with decreased reproducibility of self-reported age at menopause.

  17. Measuring stone surface area from a radiographic image is accurate and reproducible with the help of an imaging program.

    Science.gov (United States)

    Kurien, Abraham; Ganpule, Arvind; Muthu, V; Sabnis, R B; Desai, Mahesh

    2009-01-01

    The surface area of the stone from a radiographic image is one of the more suitable parameters defining stone bulk. The widely accepted method of measuring stone surface area is to count the number of square millimeters enclosed within a tracing of the stone outline on graph paper. This method is time consuming and cumbersome with potential for human error, especially when multiple measurements are needed. The purpose of this study was to evaluate the accuracy, efficiency, and reproducibility of a commercially available imaging program, Adobe Photoshop 7.0 for the measurement of stone surface area. The instructions to calculate area using the software are simple and easy in a Windows-based format. The accuracy of the imaging software was estimated by measuring surface areas of shapes of known mathematical areas. The efficiency and reproducibility were then evaluated from radiographs of 20 persons with radiopaque upper-tract urinary stones. The surface areas of stone images were measured using both graph paper and imaging software. Measurements were repeated after 10 days to assess the reproducibility of the techniques. The time taken to measure the area by the two methods was also assessed separately. The accuracy of the imaging software was estimated to be 98.7%. The correlation coefficient between the two methods was R(2) = 0.97. The mean percentage variation using the imaging software was 0.68%, while it was 6.36% with the graph paper. The mean time taken to measure using the image analyzer and graph paper was 1.9 +/- 0.8 minutes and 4.5 +/- 1.08 minutes, respectively (P stone surface area from radiographs compared with manual measurements using graph paper.

  18. A Long-Term and Reproducible Passive Microwave Sea Ice Concentration Data Record for Climate Studies and Monitoring

    Science.gov (United States)

    Peng, G.; Meier, W. N.; Scott, D. J.; Savoie, M. H.

    2013-01-01

    A long-term, consistent, and reproducible satellite-based passive microwave sea ice concentration climate data record (CDR) is available for climate studies, monitoring, and model validation with an initial operation capability (IOC). The daily and monthly sea ice concentration data are on the National Snow and Ice Data Center (NSIDC) polar stereographic grid with nominal 25 km × 25 km grid cells in both the Southern and Northern Hemisphere polar regions from 9 July 1987 to 31 December 2007. The data files are available in the NetCDF data format at http://nsidc.org/data/g02202.html and archived by the National Climatic Data Center (NCDC) of the National Oceanic and Atmospheric Administration (NOAA) under the satellite climate data record program (http://www.ncdc.noaa.gov/cdr/operationalcdrs.html). The description and basic characteristics of the NOAA/NSIDC passive microwave sea ice concentration CDR are presented here. The CDR provides similar spatial and temporal variability as the heritage products to the user communities with the additional documentation, traceability, and reproducibility that meet current standards and guidelines for climate data records. The data set, along with detailed data processing steps and error source information, can be found at http://dx.doi.org/10.7265/N5B56GN3.

  19. Reproducibility problems of in-service ultrasonic testing results

    International Nuclear Information System (INIS)

    Honcu, E.

    1974-01-01

    The reproducibility of the results of ultrasonic testing is the basic precondition for its successful application in in-service inspection of changes in the quality of components of nuclear power installations. The results of periodic ultrasonic inspections are not satisfactory from the point of view of reproducibility. Regardless, the ultrasonic pulse-type method is suitable for evaluating the quality of most components of nuclear installations and often the sole method which may be recommended for inspection with regard to its technical and economic aspects. (J.B.)

  20. Spatial aspects of sound quality - and by multichannel systems subjective assessment of sound reproduced by stereo

    DEFF Research Database (Denmark)

    Choisel, Sylvain

    the fidelity with which sound reproduction systems can re-create the desired stereo image, a laser pointing technique was developed to accurately collect subjects' responses in a localization task. This method is subsequently applied in an investigation of the effects of loudspeaker directivity...... on the perceived direction of panned sources. The second part of the thesis addresses the identification of auditory attributes which play a role in the perception of sound reproduced by multichannel systems. Short musical excerpts were presented in mono, stereo and several multichannel formats to evoke various...

  1. Two-Finger Tightness: What Is It? Measuring Torque and Reproducibility in a Simulated Model.

    Science.gov (United States)

    Acker, William B; Tai, Bruce L; Belmont, Barry; Shih, Albert J; Irwin, Todd A; Holmes, James R

    2016-05-01

    Residents in training are often directed to insert screws using "two-finger tightness" to impart adequate torque but minimize the chance of a screw stripping in bone. This study seeks to quantify and describe two-finger tightness and to assess the variability of its application by residents in training. Cortical bone was simulated using a polyurethane foam block (30-pcf density) that was prepared with predrilled holes for tightening 3.5 × 14-mm long cortical screws and mounted to a custom-built apparatus on a load cell to capture torque data. Thirty-three residents in training, ranging from the first through fifth years of residency, along with 8 staff members, were directed to tighten 6 screws to two-finger tightness in the test block, and peak torque values were recorded. The participants were blinded to their torque values. Stripping torque (2.73 ± 0.56 N·m) was determined from 36 trials and served as a threshold for failed screw placement. The average torques varied substantially with regard to absolute torque values, thus poorly defining two-finger tightness. Junior residents less consistently reproduced torque compared with other groups (0.29 and 0.32, respectively). These data quantify absolute values of two-finger tightness but demonstrate considerable variability in absolute torque values, percentage of stripping torque, and ability to consistently reproduce given torque levels. Increased years in training are weakly correlated with reproducibility, but experience does not seem to affect absolute torque levels. These results question the usefulness of two-finger tightness as a teaching tool and highlight the need for improvement in resident motor skill training and development within a teaching curriculum. Torque measuring devices may be a useful simulation tools for this purpose.

  2. Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.

    Science.gov (United States)

    Duc, Sebastien; Villerius, Vincent; Bertucci, William; Grappe, Frederic

    2007-09-01

    The ErgomoPro (EP) is a power meter that measures power output (PO) during outdoor and indoor cycling via 2 optoelectronic sensors located in the bottom bracket axis. The aim of this study was to determine the validity and the reproducibility of the EP compared with the SRM crank set and Powertap hub (PT). The validity of the EP was tested in the laboratory during 8 submaximal incremental tests (PO: 100 to 400 W), eight 30-min submaximal constant-power tests (PO = 180 W), and 8 sprint tests (PO > 750 W) and in the field during 8 training sessions (time: 181 +/- 73 min; PO: approximately 140 to 160 W). The reproducibility was assessed by calculating the coefficient of PO variation (CV) during the submaximal incremental and constant tests. The EP provided a significantly higher PO than the SRM and PT during the submaximal incremental test: The mean PO differences were +6.3% +/- 2.5% and +11.1% +/- 2.1% respectively. The difference was greater during field training sessions (+12.0% +/- 5.7% and +16.5% +/- 5.9%) but lower during sprint tests (+1.6% +/- 2.5% and +3.2% +/- 2.7%). The reproducibility of the EP is lower than those of the SRM and PT (CV = 4.1% +/- 1.8%, 1.9% +/- 0.4%, and 2.1% +/- 0.8%, respectively). The EP power meter appears less valid and reliable than the SRM and PT systems.

  3. Composting in small laboratory pilots: Performance and reproducibility

    International Nuclear Information System (INIS)

    Lashermes, G.; Barriuso, E.; Le Villio-Poitrenaud, M.; Houot, S.

    2012-01-01

    Highlights: ► We design an innovative small-scale composting device including six 4-l reactors. ► We investigate the performance and reproducibility of composting on a small scale. ► Thermophilic conditions are established by self-heating in all replicates. ► Biochemical transformations, organic matter losses and stabilisation are realistic. ► The organic matter evolution exhibits good reproducibility for all six replicates. - Abstract: Small-scale reactors ( 2 consumption and CO 2 emissions, and characterising the biochemical evolution of organic matter. A good reproducibility was found for the six replicates with coefficients of variation for all parameters generally lower than 19%. An intense self-heating ensured the existence of a spontaneous thermophilic phase in all reactors. The average loss of total organic matter (TOM) was 46% of the initial content. Compared to the initial mixture, the hot water soluble fraction decreased by 62%, the hemicellulose-like fraction by 68%, the cellulose-like fraction by 50% and the lignin-like fractions by 12% in the final compost. The TOM losses, compost stabilisation and evolution of the biochemical fractions were similar to observed in large reactors or on-site experiments, excluding the lignin degradation, which was less important than in full-scale systems. The reproducibility of the process and the quality of the final compost make it possible to propose the use of this experimental device for research requiring a mass reduction of the initial composted waste mixtures.

  4. Raising the Bar for Reproducible Science at the US Environmental Protection Agency Office of Research and Development

    Science.gov (United States)

    Considerable concern has been raised regarding research reproducibility both within and outside the scientific community. Several factors possibly contribute to a lack of reproducibility, including a failure to adequately employ statistical considerations during study design, bia...

  5. Annotating with Propp's Morphology of the Folktale: Reproducibility and Trainability

    NARCIS (Netherlands)

    Fisseni, B.; Kurji, A.; Löwe, B.

    2014-01-01

    We continue the study of the reproducibility of Propp’s annotations from Bod et al. (2012). We present four experiments in which test subjects were taught Propp’s annotation system; we conclude that Propp’s system needs a significant amount of training, but that with sufficient time investment, it

  6. Avaliação da reprodutibilidade da tomografia computadorizada no estadiamento da pancreatite aguda Reproducibility in the assessment of acute pancreatitis with computed tomography

    Directory of Open Access Journals (Sweden)

    Edison de Oliveira Freire Filho

    2007-12-01

    Full Text Available OBJETIVO: Medir a reprodutibilidade da tomografia computadorizada sem e com contraste na avaliação da gravidade da pancreatite aguda. MATERIAIS E MÉTODOS: Cinqüenta e um exames de tomografia computadorizada abdominal sem e com contraste de pacientes com pancreatite aguda foram analisados por dois radiologistas (observadores 1 e 2. Calculamos o índice morfológico pela tomografia computadorizada sem e com contraste, separadamente, e o índice de gravidade da tomografia computadorizada para pancreatite aguda. Medimos a reprodutibilidade intra- e interobservador da tomografia computadorizada através do índice kappa (kapa. RESULTADOS: Para a concordância interobservador obtivemos kapa de 0,666, 0,705, 0,648, 0,547 e 0,631 para índice morfológico sem e com contraste, presença de necrose pancreática, extensão da necrose pancreática e índice de gravidade da tomografia computadorizada, respectivamente. Para a concordância intra-observador dos observadores 1 e 2 obtivemos, respectivamente, kapa de 0,796 e 0,732 para o índice morfológico sem contraste; 0,725 e 0,802 para o índice morfológico com contraste; 0,674 e 0,849 para a presença de necrose pancreática; 0,606 e 0,770 para a extensão da necrose pancreática; e 0,801 e 0,687 para o índice de gravidade da tomografia computadorizada. CONCLUSÃO: O estadiamento da pancreatite aguda pela tomografia computadorizada por meio do índice morfológico e do índice de gravidade da tomografia computadorizada é um método bastante reprodutível. O não-uso do contraste não afeta a reprodutibilidade da tomografia computadorizada para o cálculo do índice morfológico.OBJECTIVE: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. MATERIALS AND METHODS: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two

  7. Effects of Gradient Coil Noise and Gradient Coil Replacement on the Reproducibility of Resting State Networks.

    Science.gov (United States)

    Bagarinao, Epifanio; Tsuzuki, Erina; Yoshida, Yukina; Ozawa, Yohei; Kuzuya, Maki; Otani, Takashi; Koyama, Shuji; Isoda, Haruo; Watanabe, Hirohisa; Maesawa, Satoshi; Naganawa, Shinji; Sobue, Gen

    2018-01-01

    The stability of the MRI scanner throughout a given study is critical in minimizing hardware-induced variability in the acquired imaging data set. However, MRI scanners do malfunction at times, which could generate image artifacts and would require the replacement of a major component such as its gradient coil. In this article, we examined the effect of low intensity, randomly occurring hardware-related noise due to a faulty gradient coil on brain morphometric measures derived from T1-weighted images and resting state networks (RSNs) constructed from resting state functional MRI. We also introduced a method to detect and minimize the effect of the noise associated with a faulty gradient coil. Finally, we assessed the reproducibility of these morphometric measures and RSNs before and after gradient coil replacement. Our results showed that gradient coil noise, even at relatively low intensities, could introduce a large number of voxels exhibiting spurious significant connectivity changes in several RSNs. However, censoring the affected volumes during the analysis could minimize, if not completely eliminate, these spurious connectivity changes and could lead to reproducible RSNs even after gradient coil replacement.

  8. Evaluating the reproducibility of environmental radioactivity monitoring data through replicate sample analysis

    International Nuclear Information System (INIS)

    Lindeken, C.L.; White, J.H.; Silver, W.J.

    1978-01-01

    At the Lawrence Livermore Laboratory, about 10% of the sampling effort in the environmental monitoring program represents replicate sample collection. Replication of field samples was initiated as part of the quality assurance program for environmental monitoring to determine the reproducibility of environmental measurements. In the laboratory these replicates are processed along with routine samples. As all components of variance are included in analysis of such field samples, comparison of the analytical data from replicate analyses provides a basis for estimating the overall reproducibility of the measurements. The replication study indicates that the reproducibility of environmental radioactivity monitoring data is subject to considerably more variability than is indicated by the accompanying counting errors. The data are also compared with analyses of duplicate aliquots from a well mixed sample or with duplicate aliquots of samples with known radionuclide content. These comparisons show that most of the variability is associated with the collection and preparation of the sample rather than with the analytical procedures

  9. Reproducibility of esophageal scintigraphy using semi-solid yoghurt

    Energy Technology Data Exchange (ETDEWEB)

    Imai, Yukinori; Kinoshita, Manabu; Asakura, Yasushi; Kakinuma, Tohru; Shimoji, Katsunori; Fujiwara, Kenji; Suzuki, Kenji; Miyamae, Tatsuya [Saitama Medical School, Moroyama (Japan)

    1999-10-01

    Esophageal scintigraphy is a non-invasive method which evaluate esophageal function quantitatively. We applied new technique using semi-solid yoghurt, which can evaluate esophageal function in a sitting position. To evaluate the reproducibility of this method, scintigraphy were performed in 16 healthy volunteers. From the result of four swallows except the first one, the mean coefficients of variation in esophageal transit time and esophageal emptying time were 12.8% and 13.4% respectively (interday variation). As regards the interday variation, this method had also good reproducibility from the result on the 2 separate days. (author)

  10. SU-E-J-236: Audiovisual Biofeedback Improves Breath-Hold Lung Tumor Position Reproducibility Measured with 4D MRI

    International Nuclear Information System (INIS)

    Lee, D; Pollock, S; Keall, P; Greer, P; Lapuz, C; Ludbrook, J; Kim, T

    2015-01-01

    Purpose: Audiovisual biofeedback breath-hold (AVBH) was employed to reproduce tumor position on inhale and exhale breath-holds for 4D tumor information. We hypothesize that lung tumor position will be more consistent using AVBH compared with conventional breath-hold (CBH). Methods: Lung tumor positions were determined for seven lung cancer patients (age: 25 – 74) during to two separate 3T MRI sessions. A breathhold training session was performed prior to the MRI sessions to allow patients to become comfortable with AVBH and their exhale and inhale target positions. CBH and AVBH 4D image datasets were obtained in the first MRI session (pre-treatment) and the second MRI session (midtreatment) within six weeks of the first session. Audio-instruction (MRI: Siemens Skyra) in CBH and verbal-instruction (radiographer) in AVBH were used. A radiation oncologist contoured the lung tumor using Eclipse (Varian Medical Systems); tumor position was quantified as the centroid of the contoured tumor after rigid registration based on vertebral anatomy across two MRI sessions. CBH and AVBH were compared in terms of the reproducibility assessed via (1) the difference between the two exhale positions for the two sessions and the two inhale positions for the sessions. (2) The difference in amplitude (exhale to inhale) between the two sessions. Results: Compared to CBH, AVBH improved the reproducibility of two exhale (or inhale) lung tumor positions relative to each other by 33%, from 6.4±5.3 mm to 4.3±3.0 mm (p=0.005). Compared to CBH, AVBH improved the reproducibility of exhale and inhale amplitude by 66%, from 5.6±5.9 mm to 1.9±1.4 mm (p=0.005). Conclusions: This study demonstrated that audiovisual biofeedback can be utilized for improving the reproducibility of breath-hold lung tumor position. These results are advantageous towards achieving more accurate emerging radiation treatment planning methods, in addition to imaging and treatment modalities utilizing breath

  11. SU-E-J-236: Audiovisual Biofeedback Improves Breath-Hold Lung Tumor Position Reproducibility Measured with 4D MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D; Pollock, S; Keall, P [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, NSW (Australia); Greer, P [School of Mathematical and Physical Sciences, The University of Newcastle, Newcastle, NSW (Australia); Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, NSW (Australia); Lapuz, C; Ludbrook, J [Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, NSW (Australia); Kim, T [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, NSW (Australia); Department of Radiation Oncology, University of Virginia Health System, Charlottesville, VA (United States)

    2015-06-15

    Purpose: Audiovisual biofeedback breath-hold (AVBH) was employed to reproduce tumor position on inhale and exhale breath-holds for 4D tumor information. We hypothesize that lung tumor position will be more consistent using AVBH compared with conventional breath-hold (CBH). Methods: Lung tumor positions were determined for seven lung cancer patients (age: 25 – 74) during to two separate 3T MRI sessions. A breathhold training session was performed prior to the MRI sessions to allow patients to become comfortable with AVBH and their exhale and inhale target positions. CBH and AVBH 4D image datasets were obtained in the first MRI session (pre-treatment) and the second MRI session (midtreatment) within six weeks of the first session. Audio-instruction (MRI: Siemens Skyra) in CBH and verbal-instruction (radiographer) in AVBH were used. A radiation oncologist contoured the lung tumor using Eclipse (Varian Medical Systems); tumor position was quantified as the centroid of the contoured tumor after rigid registration based on vertebral anatomy across two MRI sessions. CBH and AVBH were compared in terms of the reproducibility assessed via (1) the difference between the two exhale positions for the two sessions and the two inhale positions for the sessions. (2) The difference in amplitude (exhale to inhale) between the two sessions. Results: Compared to CBH, AVBH improved the reproducibility of two exhale (or inhale) lung tumor positions relative to each other by 33%, from 6.4±5.3 mm to 4.3±3.0 mm (p=0.005). Compared to CBH, AVBH improved the reproducibility of exhale and inhale amplitude by 66%, from 5.6±5.9 mm to 1.9±1.4 mm (p=0.005). Conclusions: This study demonstrated that audiovisual biofeedback can be utilized for improving the reproducibility of breath-hold lung tumor position. These results are advantageous towards achieving more accurate emerging radiation treatment planning methods, in addition to imaging and treatment modalities utilizing breath

  12. Reproducibility of Perfusion Parameters of Optic Disc and Macula in Rhesus Monkeys by Optical Coherence Tomography Angiography.

    Science.gov (United States)

    Li, Jing; Yang, Yi-Quan; Yang, Di-Ya; Liu, Xiang-Xiang; Sun, Yun-Xiao; Wei, Shi-Fei; Wang, Ning-Li

    2016-05-05

    Optical coherence tomography (OCT) angiography is a novel technique by which we can detect the local perfusion of fundus directly. The aim of this study was to evaluate the reproducibility of optic disc and macular flow perfusion parameters in rhesus monkeys using OCT angiography. Eighteen healthy monkeys (18 eyes) were subjected to optic disc and macula flow index measurements via a high-speed and high-resolution spectral-domain OCT XR Avanti with a split-spectrum amplitude de-correlation angiography algorithm. Right eye was imaged 3 times during the first examination and once during each of the two following examinations. The intra-visit and inter-visit intraclass correlation coefficients (ICCs) were both determined. The average flow indices of the four optic disc area layers were 0.171 ± 0.009 (optic nerve head), 0.015 ± 0.004 (vitreous), 0.052 ± 0.009 (radial peripapillary capillary), and 0.167 ± 0.011 (choroid). Average flow indices of the four macula area layers were 0.044 ± 0.011 (superficial retina), 0.036 ± 0.011 (deep retina), 0.016 ± 0.009 (outer retina), and 0.155 ± 0.013 (choroid). Intra-visit (ICC value: 0.821-0.954) and inter-visit (ICC value: 0.844-0.899) repeatability were both high. The study is about the reproducibility of optic disc and macular perfusion parameters as measured by OCT angiography in healthy rhesus monkeys. Flow index measurement reproducibility is high for both the optic disc and macula of normal monkey eyes. OCT angiography might be a useful technique to assess changes when examining monkeys with experimental ocular diseases.

  13. Estimating the reproducibility of psychological science

    NARCIS (Netherlands)

    Aarts, Alexander A.; Anderson, Joanna E.; Anderson, Christopher J.; Attridge, Peter R.; Attwood, Angela; Axt, Jordan; Babel, Molly; Bahnik, Stepan; Baranski, Erica; Barnett-Cowan, Michael; Bartmess, Elizabeth; Beer, Jennifer; Bell, Raoul; Bentley, Heather; Beyan, Leah; Binion, Grace; Borsboom, Denny; Bosch, Annick; Bosco, Frank A.; Bowman, Sara D.; Brandt, Mark J.; Braswell, Erin; Brohmer, Hilmar; Brown, Benjamin T.; Brown, Kristina; Bruening, Jovita; Calhoun-Sauls, Ann; Chagnon, Elizabeth; Callahan, Shannon P.; Chandler, Jesse; Chartier, Christopher R.; Cheung, Felix; Cillessen, Linda; Christopherson, Cody D.; Clay, Russ; Cleary, Hayley; Cloud, Mark D.; Cohn, Michael; Cohoon, Johanna; Columbus, Simon; Cordes, Andreas; Costantini, Giulio; Hartgerink, Chris; Krijnen, Job; Nuijten, Michele B.; van 't Veer, Anna E.; Van Aert, Robbie; van Assen, M.A.L.M.; Wissink, Joeri; Zeelenberg, Marcel

    2015-01-01

    INTRODUCTION Reproducibility is a defining feature of science, but the extent to which it characterizes current research is unknown. Scientific claims should not gain credence because of the status or authority of their originator but by the replicability of their supporting evidence. Even research

  14. Portuguese-language version of the Chronic Respiratory Questionnaire: a validity and reproducibility study.

    Science.gov (United States)

    Moreira, Graciane Laender; Pitta, Fábio; Ramos, Dionei; Nascimento, Cinthia Sousa Carvalho; Barzon, Danielle; Kovelis, Demétria; Colange, Ana Lúcia; Brunetto, Antonio Fernando; Ramos, Ercy Mara Cipulo

    2009-08-01

    To determine the validity and reproducibility of a Portuguese-language version of the Chronic Respiratory Questionnaire (CRQ) in patients with COPD. A Portuguese-language version of the CRQ (provided by McMaster University, the holder of the questionnaire copyright) was applied to 50 patients with COPD (70 +/- 8 years of age; 32 males; FEV1 = 47 +/- 18% of predicted) on two occasions, one week apart. The CRQ has four domains (dyspnea, fatigue, emotional function, and mastery) and was applied as an interviewer-administered instrument. The Saint George's Respiratory Questionnaire (SGRQ), already validated for use in Brazil, was used as the criterion for validation. Spirometry and the six-minute walk test (6MWT) were performed to analyze the correlations with the CRQ scores. There were no significant CRQ test-retest differences (p > 0.05 for all domains). The test-retest intraclass correlation coefficient was 0.98, 0.97, 0.98 and 0.95 for the dyspnea, fatigue, emotional function and mastery domains, respectively. The Cronbach's alpha coefficient was 0.91. The CRQ domains correlated significantly with the SGRQ domains (-0.30 < r < -0.67; p < 0.05). There were no significant correlations between spirometric variables and the CRQ domains or between the CRQ domains and the 6MWT, with the exception of the fatigue domain (r = 0.30; p = 0.04). The Portuguese-language version of the CRQ proved to be reproducible and valid for use in Brazilian patients with COPD.

  15. Short- and long-term quantitation reproducibility of brain metabolites in the medial wall using proton echo planar spectroscopic imaging.

    Science.gov (United States)

    Tsai, Shang-Yueh; Lin, Yi-Ru; Wang, Woan-Chyi; Niddam, David M

    2012-11-15

    Proton echo planar spectroscopic imaging (PEPSI) is a fast magnetic resonance spectroscopic imaging (MRSI) technique that allows mapping spatial metabolite distributions in the brain. Although the medial wall of the cortex is involved in a wide range of pathological conditions, previous MRSI studies have not focused on this region. To decide the magnitude of metabolic changes to be considered significant in this region, the reproducibility of the method needs to be established. The study aims were to establish the short- and long-term reproducibility of metabolites in the right medial wall and to compare regional differences using a constant short-echo time (TE30) and TE averaging (TEavg) optimized to yield glutamatergic information. 2D sagittal PEPSI was implemented at 3T using a 32 channel head coil. Acquisitions were repeated immediately and after approximately 2 weeks to assess the coefficients of variation (COV). COVs were obtained from eight regions-of-interest (ROIs) of varying size and location. TE30 resulted in better spectral quality and similar or lower quantitation uncertainty for all metabolites except glutamate (Glu). When Glu and glutamine (Gln) were quantified together (Glx) reduced quantitation uncertainty and increased reproducibility was observed for TE30. TEavg resulted in lowered quantitation uncertainty for Glu but in less reliable quantification of several other metabolites. TEavg did not result in a systematically improved short- or long-term reproducibility for Glu. The ROI volume was a major factor influencing reproducibility. For both short- and long-term repetitions, the Glu COVs obtained with TEavg were 5-8% for the large ROIs, 12-17% for the medium sized ROIs and 16-26% for the smaller cingulate ROIs. COVs obtained with TE30 for the less specific Glx were 3-5%, 8-10% and 10-15%. COVs for N-acetyl aspartate, creatine and choline using TE30 with long-term repetition were between 2-10%. Our results show that the cost of more specific

  16. Magnet stability and reproducibility

    CERN Document Server

    Marks, N

    2010-01-01

    Magnet stability and reproducibility have become increasingly important as greater precision and beams with smaller dimension are required for research, medical and other purpose. The observed causes of mechanical and electrical instability are introduced and the engineering arrangements needed to minimize these problems discussed; the resulting performance of a state-of-the-art synchrotron source (Diamond) is then presented. The need for orbit feedback to obtain best possible beam stability is briefly introduced, but omitting any details of the necessary technical equipment, which is outside the scope of the presentation.

  17. Reproducibility of Macular Pigment Optical Density Measurement by Two-wave Length Auto-fluorescence in a Clinical Setting

    Science.gov (United States)

    You, Qi-Sheng; Bartsch, Dirk-Uwe G.; Espina, Mark; Alam, Mostafa; Camacho, Natalia; Mendoza, Nadia; Freeman, William

    2015-01-01

    Purpose Macular pigment, composed of lutein, zeaxanthin, and meso-zeaxanthin, is postulated to protect against age-related macular degeneration (AMD), likely due to filtering blue light and its antioxidant properties. Macular pigment optical density (MPOD) is reported to be associated with macular function evaluated by visual acuity and multifocal electroretinogram. Given the importance of macular pigment, reliable and accurate measurement methods are important. The main purpose of current study is to determine the reproducibility of MPOD measurement by two-wave length auto-fluorescence method using scanning laser ophthalmoscopy. Methods Sixty eight eyes of 39 persons were enrolled in the study, including 11 normal eyes, 16 eyes with wet AMD, 16 eyes with dry AMD, 11 eyes with macular edema due to diabetic mellitus, branch retinal vein occlusion or macular telangiectasia and 14 eyes with tractional maculopathy including vitreomacular traction, epiretinal membrane or macular hole. MPOD was measured with a two-wavelength (488 and 514 nm) auto-fluorescence method with the Spectralis HRA+OCT after pupil dilation. The measurement was repeated for each eye 10 minutes later. The Analysis of variance (ANOVA) and Bland-Altman plot were used to assess the reproducibility between the two measurements. Results The mean MPOD at eccentricities of 1° and 2° was 0.36±0.17 (range: 0.04–0.69) and 0.15±0.08(range: −0.03, 0.35) for the first measurement and 0.35±0.17 (range: 0.02, 0.68) and 0.15±0.08 (range: −0.01, 0.33) for the second measurement respectively. The difference between the two measurements was not statistically significant, and the Bland-Altman plot showed 7.4% and 5.9% points outside the 95% limits of agreement, indicating an overall excellent reproducibility. Similarly, there is no significant difference between the first and second measurements of MPOD volume within eccentricities of 1°, 2° and 6° radius, and the Bland-Altman plot showed 8.8%, 2.9% and

  18. Reproducibility of 5-HT2A receptor measurements and sample size estimations with [18F]altanserin PET using a bolus/infusion approach

    International Nuclear Information System (INIS)

    Haugboel, Steven; Pinborg, Lars H.; Arfan, Haroon M.; Froekjaer, Vibe M.; Svarer, Claus; Knudsen, Gitte M.; Madsen, Jacob; Dyrby, Tim B.

    2007-01-01

    To determine the reproducibility of measurements of brain 5-HT 2A receptors with an [ 18 F]altanserin PET bolus/infusion approach. Further, to estimate the sample size needed to detect regional differences between two groups and, finally, to evaluate how partial volume correction affects reproducibility and the required sample size. For assessment of the variability, six subjects were investigated with [ 18 F]altanserin PET twice, at an interval of less than 2 weeks. The sample size required to detect a 20% difference was estimated from [ 18 F]altanserin PET studies in 84 healthy subjects. Regions of interest were automatically delineated on co-registered MR and PET images. In cortical brain regions with a high density of 5-HT 2A receptors, the outcome parameter (binding potential, BP 1 ) showed high reproducibility, with a median difference between the two group measurements of 6% (range 5-12%), whereas in regions with a low receptor density, BP 1 reproducibility was lower, with a median difference of 17% (range 11-39%). Partial volume correction reduced the variability in the sample considerably. The sample size required to detect a 20% difference in brain regions with high receptor density is approximately 27, whereas for low receptor binding regions the required sample size is substantially higher. This study demonstrates that [ 18 F]altanserin PET with a bolus/infusion design has very low variability, particularly in larger brain regions with high 5-HT 2A receptor density. Moreover, partial volume correction considerably reduces the sample size required to detect regional changes between groups. (orig.)

  19. 18F-Fluorodeoxyglucose positron emission tomography pulmonary imaging in idiopathic pulmonary fibrosis is reproducible: implications for future clinical trials

    International Nuclear Information System (INIS)

    Win, Thida; Lambrou, Tryphon; Hutton, Brian F.; Kayani, Irfan; Endozo, Raymondo; Shortman, Robert I.; Groves, Ashley M.; Screaton, Nicholas J.; Porter, Joanna C.; Maher, Toby M.; Lukey, Pauline

    2012-01-01

    Noninvasive markers of disease activity in patients with idiopathic pulmonary fibrosis (IPF) are lacking. We performed this study to investigate the reproducibility of pulmonary 18 F-FDG PET/CT in patients with IPF. The study group comprised 13 patients (11 men, 2 women; mean age 71.1 ± 9.9 years) with IPF recruited for two thoracic 18 F-FDG PET/CT studies performed within 2 weeks of each other. All patients were diagnosed with IPF in consensus at multidisciplinary meetings as a result of typical clinical, high-resolution CT and pulmonary function test features. Three methods for evaluating pulmonary 18 F-FDG uptake were used. The maximal 18 F-FDG pulmonary uptake (SUVmax) in the lungs was determined using manual region-of-interest placement. An 18 F-FDG uptake intensity histogram was automatically constructed from segmented lungs to evaluate the distribution of SUVs. Finally, mean SUV was determined for volumes-of-interest in pulmonary regions with interstitial lung changes identified on CT scans. Processing included correction for tissue fraction effects. Bland-Altman analysis was performed and interclass correlation coefficients (ICC) were determined to assess the reproducibility between the first and second PET scans, as well as the level of intraobserver and interobserver agreement. The mean time between the two scans was 6.3 ± 4.3 days. The interscan ICCs for pulmonary SUVmax analysis and mean SUV corrected for tissue fraction effects were 0.90 and 0.91, respectively. Intensity histograms were different in only 1 of the 13 paired studies. Intraobserver agreement was also excellent (0.80 and 0.85, respectively). Some bias was observed between observers, suggesting that serial studies would benefit from analysis by the same observer. This study demonstrated that there is excellent short-term reproducibility in pulmonary 18 F-FDG uptake in patients with IPF. (orig.)

  20. Development, validation and reproducibility of a food frequency questionnaire to measure flavonoid intake in older Australian adults.

    Science.gov (United States)

    Kent, Katherine; Charlton, Karen E

    2018-02-01

    To develop and assess the validity and reproducibility of a food frequency questionnaire (FFQ) to measure total flavonoid intake, and individual flavonoid subclasses, in older adults. Retrospective analysis of flavonoid intake in older adults informed the development of a FFQ to measure flavonoid intake and determine the flavonoid subclasses consumed (anthocyanins, flavan-3-ols, flavones, flavonols and flavanones). Older adults (n = 42, mean age 75.3 ± 8.6 years) attended two interviews 1 month apart where anthropometrics (height and weight), blood pressure (BP), demographic data and a 93-item self-administered FFQ were collected. A 4-day food record (FR) was randomly administered between the two interview dates, and each food item was assigned a flavonoid and flavonoid subclass content using the United States Department of Agriculture flavonoid database. The criterion validity and reproducibility of the FFQ was assessed against a 4-day FR using the Wilcoxon signed-rank sum test, Spearman's correlation coefficient (r), Bland-Altman Plots and Cohen's kappa. Total flavonoid intake was determined (median intake FFQ = 919.3 mg/day, FR = 781.4 mg/day). Tests of validity indicated that the FFQ consistently overestimated total flavonoid intake compared with the 4-day FR. There was a significant difference in estimates between the FFQ and the 4-day FR for total flavonoid intake (Wilcoxon signed-rank sum P tests of validity indicated greater discrepancy compared with 4-day FR. The FFQ showed high reproducibility for estimating total flavonoid intake (FFQ1vsFFQ2: Wilcoxon signed-rank sum test, P > 0.05; Spearman's r 0.91, P tests of reproducibility between FFQ1 and FFQ2 showed similarly high reproducibility. The developed FFQ appears suitable for satisfactorily ranking individuals according to total flavonoid intake. The FFQ shows limitations for estimating absolute total flavonoid intake and intake of flavonoid subclasses in comparison to a 4-day FR in terms of

  1. Reproducibility of an aerobic endurance test for nonexpert swimmers.

    Science.gov (United States)

    Veronese da Costa, Adalberto; Costa, Manoel da Cunha; Carlos, Daniel Medeiros; Guerra, Luis Marcos de Medeiros; Silva, Antônio José; Barbosa, Tiago Manoel Cabral Dos Santos

    2012-01-01

    This study aimed to verify the reproduction of an aerobic test to determine nonexpert swimmers' resistance. The sample consisted of 24 male swimmers (age: 22.79 ± 3.90 years; weight: 74.72 ± 11.44 kg; height: 172.58 ± 4.99 cm; and fat percentage: 15.19% ± 3.21%), who swim for 1 hour three times a week. A new instrument was used in this study (a Progressive Swim Test): the swimmer wore an underwater MP3 player and increased their swimming speed on hearing a beep after every 25 meters. Each swimmer's heart rate was recorded before the test (BHR) and again after the test (AHR). The rate of perceived exertion (RPE) and the number of laps performed (NLP) were also recorded. The sample size was estimated using G*Power software (v 3.0.10; Franz Faul, Kiel University, Kiel, Germany). The descriptive values were expressed as mean and standard deviation. After confirming the normality of the data using both the Shapiro-Wilk and Levene tests, a paired t-test was performed to compare the data. The Pearson's linear correlation (r) and intraclass coefficient correlation (ICC) tests were used to determine relative reproducibility. The standard error of measurement (SEM) and the coefficient of variation (CV) were used to determine absolute reproducibility. The limits of agreement and the bias of the absolute and relative values between days were determined by Bland-Altman plots. All values had a significance level of P 0.50 and ICC > 0.66. The SEM had a variation of ±2% and the CV was 0.90; SEM swimmers. The Progressive Swim Test for nonexpert swimmers produces comparable results for noncompetitive swimmers with a favorable degree of reproducibility, thus presenting possible applications for researching the physiological performance of nonexpert swimmers.

  2. The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy

    International Nuclear Information System (INIS)

    Dawson, Laura A.; Brock, Kristy K.; Kazanjian, Sahira; Fitch, Dwight; McGinn, Cornelius J.; Lawrence, Theodore S.; Haken, Randall K. ten; Balter, James

    2001-01-01

    Purpose: To evaluate the intrafraction and interfraction reproducibility of liver immobilization using active breathing control (ABC). Methods and Materials: Patients with unresectable intrahepatic tumors who could comfortably hold their breath for at least 20 s were treated with focal liver radiation using ABC for liver immobilization. Fluoroscopy was used to measure any potential motion during ABC breath holds. Preceding each radiotherapy fraction, with the patient setup in the nominal treatment position using ABC, orthogonal radiographs were taken using room-mounted diagnostic X-ray tubes and a digital imager. The radiographs were compared to reference images using a 2D alignment tool. The treatment table was moved to produce acceptable setup, and repeat orthogonal verification images were obtained. The positions of the diaphragm and the liver (assessed by localization of implanted radiopaque intra-arterial microcoils) relative to the skeleton were subsequently analyzed. The intrafraction reproducibility (from repeat radiographs obtained within the time period of one fraction before treatment) and interfraction reproducibility (from comparisons of the first radiograph for each treatment with a reference radiograph) of the diaphragm and the hepatic microcoil positions relative to the skeleton with repeat breath holds using ABC were then measured. Caudal-cranial (CC), anterior-posterior (AP), and medial-lateral (ML) reproducibility of the hepatic microcoils relative to the skeleton were also determined from three-dimensional alignment of repeat CT scans obtained in the treatment position. Results: A total of 262 fractions of radiation were delivered using ABC breath holds in 8 patients. No motion of the diaphragm or hepatic microcoils was observed on fluoroscopy during ABC breath holds. From analyses of 158 sets of positioning radiographs, the average intrafraction CC reproducibility (σ) of the diaphragm and hepatic microcoil position relative to the skeleton

  3. Reproducibility and validity of the food frequency questionnaire for estimating habitual dietary intake in children and adolescents

    Science.gov (United States)

    2011-01-01

    Background A previous study reported the development a 75-item food frequency questionnaire for Japanese children (CFFQ). The first aim was to examine the reproducibility and validity of the CFFQ in order to assess dietary intake among two groups; 3-11 year old children (YC group) and 12-16 year old children (AD group). The second aim was to use the CFFQ and the FFQ for adults (AFFQ), and to determine which was better suited for assessing the intake of children in each group. Methods A total of the 103 children participated in this study. The interval between the first CFFQ and AFFQ and the second CFFQ and AFFQ was one month. Four weighted dietary records (WDRs) were conducted once a week. Pearson's correlation coefficients between the first and second FFQs were calculated to test the reproducibility of each FFQ. Pearson's correlation coefficients between WDRs and the second FFQ were calculated for the unadjusted value and sex-, age-, and energy-adjusted values to determine the validity of each FFQ. Results The final number of subjects participating in the analysis was 89. The median correlation coefficients between the first and second CFFQs and AFFQs were 0.76 and 0.73, respectively. There was some over/underestimation of nutrients in the CFFQ of the YC group and in the AFFQ of the AD group. The medians of the sex-, age-, and energy-adjusted correlation coefficients were not different between the YC and AD groups for each FFQ. The correlation coefficient in sex-, age-, and energy-adjusted value revealed that the largest number of subject with high (0.50 or more) value was obtained by the CFFQ in the YC group. Conclusions This study indicated that the CFFQ might be a useful tool for assessing habitual dietary intake of children in the YC group. Although the CFFQ agreed moderately with habitual intake, it was found to underestimate intake in theAD group. However, for the AFFQ, the ability to rank habitual intake was low. Therefore, it is necessary to develop a new

  4. Comparison of fMRI paradigms assessing visuospatial processing: Robustness and reproducibility.

    Directory of Open Access Journals (Sweden)

    Verena Schuster

    Full Text Available The development of brain imaging techniques, in particular functional magnetic resonance imaging (fMRI, made it possible to non-invasively study the hemispheric lateralization of cognitive brain functions in large cohorts. Comprehensive models of hemispheric lateralization are, however, still missing and should not only account for the hemispheric specialization of individual brain functions, but also for the interactions among different lateralized cognitive processes (e.g., language and visuospatial processing. This calls for robust and reliable paradigms to study hemispheric lateralization for various cognitive functions. While numerous reliable imaging paradigms have been developed for language, which represents the most prominent left-lateralized brain function, the reliability of imaging paradigms investigating typically right-lateralized brain functions, such as visuospatial processing, has received comparatively less attention. In the present study, we aimed to establish an fMRI paradigm that robustly and reliably identifies right-hemispheric activation evoked by visuospatial processing in individual subjects. In a first study, we therefore compared three frequently used paradigms for assessing visuospatial processing and evaluated their utility to robustly detect right-lateralized brain activity on a single-subject level. In a second study, we then assessed the test-retest reliability of the so-called Landmark task-the paradigm that yielded the most robust results in study 1. At the single-voxel level, we found poor reliability of the brain activation underlying visuospatial attention. This suggests that poor signal-to-noise ratios can become a limiting factor for test-retest reliability. This represents a common detriment of fMRI paradigms investigating visuospatial attention in general and therefore highlights the need for careful considerations of both the possibilities and limitations of the respective fMRI paradigm-in particular

  5. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway.

    Directory of Open Access Journals (Sweden)

    Samantha Torres Grams

    Full Text Available Maximal Inspiratory Pressure (MIP is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway.This study aimed to compare the MIP values assessed by standard method (MIPsta and by unidirectional expiratory valve method (MIPuni in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated.This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B at two moments (Tests 1 and 2 to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1] was used to determine intraobserver and interobserver reproducibility.The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O than the mean values for MIPsta (-102.5 ± 23.9 cmH2O (p<0.001. Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91, and high correlation for Test 2 (ICC[2,1] = 0.88. The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86 and evaluator B (ICC[2,1] = 0.77.MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway.

  6. Reproducibility of skeletal muscle vasodilatation responses to Stroop mental challenge over repeated sessions.

    Science.gov (United States)

    Hamer, Mark; Boutcher, Yati N; Park, Young; Boutcher, Stephen H

    2006-08-01

    Skeletal muscle blood flow responses to stress have implications for psychobiological disease pathways. An important assumption underlying psychophysiological studies relating stress reactivity with disease risk is that individuals are characterized by stable response profiles that can be reliably assessed using acute psychophysiological stress testing. We examined the reproducibility of forearm vasodilatation, blood pressure, and cardiac responses to a 2 min Stroop mental challenge over two repeated stress sessions that were on average 3.6 months apart. Participants were 21 healthy men and women (aged 21.8+/-3.7 years). Vasodilatation, blood pressure and heart rate responses displayed no habituation between sessions, although there was significantly greater cardiac parasympathetic involvement during the second testing session. Significant test-retest correlations between the sessions were observed for both forearm blood flow and heart rate reactivity. These findings demonstrate skeletal muscle vasodilatation responses to repeated stress are robust, so may be a useful psychophysiological indicator in studies of stress reactivity and disease risk.

  7. Inexperienced clinicians can extract pathoanatomic information from MRI narrative reports with high reproducability for use in research/quality assurance

    DEFF Research Database (Denmark)

    Kent, Peter; Briggs, Andrew M; Albert, Hanne Birgit

    2011-01-01

    Background Although reproducibility in reading MRI images amongst radiologists and clinicians has been studied previously, no studies have examined the reproducibility of inexperienced clinicians in extracting pathoanatomic information from magnetic resonance imaging (MRI) narrative reports and t...

  8. Reproducibility of the pink esthetic score--rating soft tissue esthetics around single-implant restorations with regard to dental observer specialization.

    Science.gov (United States)

    Gehrke, Peter; Lobert, Markus; Dhom, Günter

    2008-01-01

    The pink esthetic score (PES) evaluates the esthetic outcome of soft tissue around implant-supported single crowns in the anterior zone by awarding seven points for the mesial and distal papilla, soft-tissue level, soft-tissue contour, soft-tissue color, soft-tissue texture, and alveolar process deficiency. The aim of this study was to measure the reproducibility of the PES and assess the influence exerted by the examiner's degree of dental specialization. Fifteen examiners (three general dentists, three oral maxillofacial surgeons, three orthodontists, three postgraduate students in implant dentistry, and three lay people) applied the PES to 30 implant-supported single restorations twice at an interval of 4 weeks. Using a 0-1-2 scoring system, 0 being the lowest, 2 being the highest value, the maximum achievable PES was 14. At the second assessment, the photographs were scored in reverse order. Differences between the two assessments were evaluated with the Spearman's rank correlation coefficient (R). The Wilcoxon signed-rank test was used for comparisons of differences between the ratings. A significance level of p esthetic restorations showed the smallest deviations. Orthodontists were found to have assigned significantly poorer ratings than any other group. The assessment of postgraduate students and laypersons were the most favorable. The PES allows for a more objective appraisal of the esthetic short- and long-term results of various surgical and prosthetic implant procedures. It reproducibly evaluates the peri-implant soft tissue around single-implant restorations and results in good intra-examiner agreement. However, an effect of observer specialization on rating soft-tissue esthetics can be shown.

  9. Thickness of patellofemoral articular cartilage as measured on MR imaging: sequence comparison of accuracy, reproducibility, and interobserver variation

    Energy Technology Data Exchange (ETDEWEB)

    Van Leersum, M.D. [Dept. of Radiology, Thomas Jefferson Univ. Hospital, Philadelphia, PA (United States); Schweitzer, M.E. [Dept. of Radiology, Thomas Jefferson Univ. Hospital, Philadelphia, PA (United States); Gannon, F. [Dept. of Pathology, Thomas Jefferson Univ. Hospital, Philadelphia, PA (United States); Vinitski, S. [Dept. of Radiology, Thomas Jefferson Univ. Hospital, Philadelphia, PA (United States); Finkel, G. [Dept. of Pathology, Thomas Jefferson Univ. Hospital, Philadelphia, PA (United States); Mitchell, D.G. [Dept. of Radiology, Thomas Jefferson Univ. Hospital, Philadelphia, PA (United States)

    1995-08-01

    This study was undertaken to assess the accuracy, precision, and reliability of magnetic resonance (MR) measurements of articular cartilage. Fifteen cadaveric patellas were imaged in the axial plane at 1.5 T. Gradient echo and fat-suppressed FSE, T2-weighted, proton density, and T1-weighted sequences were performed. We measured each 5-mm section separately at three standardized positions, giving a total of 900 measurements. These findings were correlated with independently performed measurements of the corresponding anatomic sections. A hundred random measurements were also evaluated for reproducibility and interobserver variation. Although all sequences were highly accurate, the T1-weighted images were the most accurate, with a mean difference of 0.25 mm and a correlation coefficient of 0.85. All sequences were also highly reproducible with little inter-observer variation. In an attempt to improve the accuracy of the MR measurements further, we retrospectively evaluated all measurements with discrepancies greater than 1 mm from the specimen. All these differences were attributable to focal defects causing exaggeration of the thickness on MR imaging. (orig.)

  10. Thickness of patellofemoral articular cartilage as measured on MR imaging: sequence comparison of accuracy, reproducibility, and interobserver variation

    International Nuclear Information System (INIS)

    Van Leersum, M.D.; Schweitzer, M.E.; Gannon, F.; Vinitski, S.; Finkel, G.; Mitchell, D.G.

    1995-01-01

    This study was undertaken to assess the accuracy, precision, and reliability of magnetic resonance (MR) measurements of articular cartilage. Fifteen cadaveric patellas were imaged in the axial plane at 1.5 T. Gradient echo and fat-suppressed FSE, T2-weighted, proton density, and T1-weighted sequences were performed. We measured each 5-mm section separately at three standardized positions, giving a total of 900 measurements. These findings were correlated with independently performed measurements of the corresponding anatomic sections. A hundred random measurements were also evaluated for reproducibility and interobserver variation. Although all sequences were highly accurate, the T1-weighted images were the most accurate, with a mean difference of 0.25 mm and a correlation coefficient of 0.85. All sequences were also highly reproducible with little inter-observer variation. In an attempt to improve the accuracy of the MR measurements further, we retrospectively evaluated all measurements with discrepancies greater than 1 mm from the specimen. All these differences were attributable to focal defects causing exaggeration of the thickness on MR imaging. (orig.)

  11. Using the mouse to model human disease: increasing validity and reproducibility

    Directory of Open Access Journals (Sweden)

    Monica J. Justice

    2016-02-01

    Full Text Available Experiments that use the mouse as a model for disease have recently come under scrutiny because of the repeated failure of data, particularly derived from preclinical studies, to be replicated or translated to humans. The usefulness of mouse models has been questioned because of irreproducibility and poor recapitulation of human conditions. Newer studies, however, point to bias in reporting results and improper data analysis as key factors that limit reproducibility and validity of preclinical mouse research. Inaccurate and incomplete descriptions of experimental conditions also contribute. Here, we provide guidance on best practice in mouse experimentation, focusing on appropriate selection and validation of the model, sources of variation and their influence on phenotypic outcomes, minimum requirements for control sets, and the importance of rigorous statistics. Our goal is to raise the standards in mouse disease modeling to enhance reproducibility, reliability and clinical translation of findings.

  12. Reproducibility and Relative Validity of a Short Food Frequency Questionnaire in 9-10 Year-Old Children.

    Science.gov (United States)

    Saeedi, Pouya; Skeaff, Sheila A; Wong, Jyh Eiin; Skidmore, Paula M L

    2016-05-07

    The aim of this study was to assess the reproducibility and validity of a non-quantitative 28-item food frequency questionnaire (FFQ). Children aged 9-10 years (n = 50) from three schools in Dunedin, New Zealand, completed the FFQ twice and a four-day estimated food diary (4DEFD) over a two-week period. Intraclass correlation coefficients (ICC) and Spearman's correlation coefficients (SCC) were used to determine reproducibility and validity of the FFQ, respectively. Weekly intakes were estimated for each food item and aggregated into 23 food items/groups. More than half of the food items/groups (52.2%) had an ICC ≥0.5. The median SCC between FFQ administrations was 0.66 (ranging from 0.40 for processed meat to 0.82 for sweets and non-dairy drinks). Cross-classification analysis between the first FFQ and 4DEFD for ranking participants into thirds showed that breakfast cereals had the highest agreement (54.0%) and pasta the lowest (34.0%). In validity analyses, 70% of food items/groups had a SCC ≥0.3. Results indicate that the FFQ is a useful tool for ranking children according to food items/groups intake. The low respondent burden and relative simplicity of the FFQ makes it suitable for use in large cohort studies of 9-10 year-old children in New Zealand.

  13. Interobserver and test-retest reproducibility of T1ρ and T2 mesurements of lumber intervertebral discs by 3t magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Yeon Hwa; Yoon, Choon Sik; Eun, Na Lae; Kim, Sung Jin; Chung, Tae Sub [Dept. of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Hwang, Moon Jung [GE Health Care, Seoul (Korea, Republic of); Yoo, Hanna [Biostatistics Collaboration Lab, Yonsei University College of Medicine, Seoul (Korea, Republic of); Peter, Robert D. [GE Health Care, Milwaukee (United States); Lee, Young Han; Suh, Jin Suck [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-11-15

    To investigate the interobserver and test-retest reproducibility of T1ρ and T2 measurements of lumbar intervertebral discs using 3T magnetic resonance imaging (MRI). This study included a total of 51 volunteers (female, 26; male, 25; mean age, 54 ± 16.3 years) who underwent lumbar spine MRI with a 3.0 T scanner. Amongst these subjects, 40 underwent repeat T1ρ and T2 measurement acquisitions with identical image protocol. Two observers independently performed the region of interest measurements in the nuclei pulposi of the discs from L1-2 through L5-S1 levels. Statistical analysis was performed using intraclass correlation coefficient (ICC) with a two-way random model of absolute agreement. Comparison of the ICC values was done after acquisition of ICC values using Z test. Statistical significance was defined as p value < 0.05. The ICCs of interobserver reproducibility were 0.951 and 0.672 for T1ρ and T2 mapping, respectively. The ICCs of test-retest reproducibility (40 subjects) for T1ρ and T2 measurements were 0.922 and 0.617 for observer A and 0.914 and 0.628 for observer B, respectively. In the comparison of the aforementioned ICCs, ICCs of interobserver and test-retest reproducibility for T1ρ mapping were significantly higher than T2 mapping (p < 0.001). The interobserver and test-retest reproducibility of T1ρ mapping were significantly higher than those of T2 mapping for the quantitative assessment of nuclei pulposi of lumbar intervertebral discs.

  14. Reproducible insulin secretion from isolated rat pancreas preparations using an organ bath.

    Science.gov (United States)

    Morita, Asuka; Ouchi, Motoshi; Terada, Misao; Kon, Hiroe; Kishimoto, Satoko; Satoh, Keitaro; Otani, Naoyuki; Hayashi, Keitaro; Fujita, Tomoe; Inoue, Ken-Ichi; Anzai, Naohiko

    2018-02-09

    Diabetes mellitus is a lifestyle-related disease that is characterized by inappropriate or diminished insulin secretion. Ex vivo pharmacological studies of hypoglycemic agents are often conducted using perfused pancreatic preparations. Pancreas preparations for organ bath experiments do not require cannulation and are therefore less complex than isolated perfused pancreas preparations. However, previous research has generated almost no data on insulin secretion from pancreas preparations using organ bath preparations. The purpose of this study was to investigate the applicability of isolated rat pancreas preparations using the organ bath technique in the quantitative analysis of insulin secretion from β-cells. We found that insulin secretion significantly declined during incubation in the organ bath, whereas it was maintained in the presence of 1 µM GLP-1. Conversely, amylase secretion exhibited a modest increase during incubation and was not altered in the presence of GLP-1. These results demonstrate that the pancreatic organ bath preparation is a sensitive and reproducible method for the ex vivo assessment of the pharmacological properties of hypoglycemic agents.

  15. Efficient and reproducible mammalian cell bioprocesses without probes and controllers?

    Science.gov (United States)

    Tissot, Stéphanie; Oberbek, Agata; Reclari, Martino; Dreyer, Matthieu; Hacker, David L; Baldi, Lucia; Farhat, Mohamed; Wurm, Florian M

    2011-07-01

    Bioprocesses for recombinant protein production with mammalian cells are typically controlled for several physicochemical parameters including the pH and dissolved oxygen concentration (DO) of the culture medium. Here we studied whether these controls are necessary for efficient and reproducible bioprocesses in an orbitally shaken bioreactor (OSR). Mixing, gas transfer, and volumetric power consumption (P(V)) were determined in both a 5-L OSR and a 3-L stirred-tank bioreactor (STR). The two cultivation systems had a similar mixing intensity, but the STR had a lower volumetric mass transfer coefficient of oxygen (k(L)a) and a higher P(V) than the OSR. Recombinant CHO cell lines expressing either tumor necrosis factor receptor as an Fc fusion protein (TNFR:Fc) or an anti-RhesusD monoclonal antibody were cultivated in the two systems. The 5-L OSR was operated in an incubator shaker with 5% CO(2) in the gas environment but without pH and DO control whereas the STR was operated with or without pH and DO control. Higher cell densities and recombinant protein titers were obtained in the OSR as compared to both the controlled and the non-controlled STRs. To test the reproducibility of a bioprocess in a non-controlled OSR, the two CHO cell lines were each cultivated in parallel in six 5-L OSRs. Similar cell densities, cell viabilities, and recombinant protein titers along with similar pH and DO profiles were achieved in each group of replicates. Our study demonstrated that bioprocesses can be performed in OSRs without pH or DO control in a highly reproducible manner, at least at the scale of operation studied here. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Improvement of reproducibility and quality control of human growth hormone radioiodination

    International Nuclear Information System (INIS)

    Bartolini, P.; Ribela, M.T.C.P.; Camilo, M.A.

    1988-01-01

    The labelling reaction of human growth hormone (hGH) with 125 I and its chromatographic purification have been studied with emphasis on the reproducibility of the yields, quantitaTive recoveries and resulting activities. Through the accurate standardization of a monitoring technique, it is confirmed that there are no significant losses in radioactivity or protein during the labelling or purification process. By strict control of the reaction conditions a fairily good reproducibility is also obtained in the labelling of various hGH extracts with diferent 125 I shipments used after short or long storage. Finally, the specific activity (or absolute mass) of the radioiodinated protein is determined by this Analysis of the Reaction Mixture and compared to the widely used radioimmunological assay (Self-displacement). (M.A.C.) [pt

  17. Production process reproducibility and product quality consistency of transient gene expression in HEK293 cells with anti-PD1 antibody as the model protein.

    Science.gov (United States)

    Ding, Kai; Han, Lei; Zong, Huifang; Chen, Junsheng; Zhang, Baohong; Zhu, Jianwei

    2017-03-01

    Demonstration of reproducibility and consistency of process and product quality is one of the most crucial issues in using transient gene expression (TGE) technology for biopharmaceutical development. In this study, we challenged the production consistency of TGE by expressing nine batches of recombinant IgG antibody in human embryonic kidney 293 cells to evaluate reproducibility including viable cell density, viability, apoptotic status, and antibody yield in cell culture supernatant. Product quality including isoelectric point, binding affinity, secondary structure, and thermal stability was assessed as well. In addition, major glycan forms of antibody from different batches of production were compared to demonstrate glycosylation consistency. Glycan compositions of the antibody harvested at different time periods were also measured to illustrate N-glycan distribution over the culture time. From the results, it has been demonstrated that different TGE batches are reproducible from lot to lot in overall cell growth, product yield, and product qualities including isoelectric point, binding affinity, secondary structure, and thermal stability. Furthermore, major N-glycan compositions are consistent among different TGE batches and conserved during cell culture time.

  18. Reproducibility of suppression of Pythium wilt of cucumber by compost

    Directory of Open Access Journals (Sweden)

    Mauritz Vilhelm Vestberg

    2014-10-01

    Full Text Available There is increasing global interest in using compost to suppress soil-borne fungal and bacterial diseases and nematodes. We studied the reproducibility of compost suppressive capacity (SC against Pythium wilt of cucumber using nine composts produced by the same composting plant in 2008 and 2009. A bioassay was set up in a greenhouse using cucumber inoculated with two strains of Pythium. The composts were used as 20% mixtures (v:v of a basic steam-sterilized light Sphagnum peat and sand (3:1, v:v. Shoot height was measured weekly during the 5-week experiment. At harvest, the SC was calculated as the % difference in shoot dry weight (DW between non-inoculated and inoculated cucumbers. The SC was not affected by year of production (2008 or 2009, indicating reproducibility of SC when the raw materials and the composting method are not changed. Differences in shoot height were not as pronounced as those for shoot DW. The results were encouraging, but further studies are still needed for producing compost with guaranteed suppressiveness properties.

  19. The quest for improved reproducibility in MALDI mass spectrometry.

    Science.gov (United States)

    O'Rourke, Matthew B; Djordjevic, Steven P; Padula, Matthew P

    2018-03-01

    Reproducibility has been one of the biggest hurdles faced when attempting to develop quantitative protocols for MALDI mass spectrometry. The heterogeneous nature of sample recrystallization has made automated sample acquisition somewhat "hit and miss" with manual intervention needed to ensure that all sample spots have been analyzed. In this review, we explore the last 30 years of literature and anecdotal evidence that has attempted to address and improve reproducibility in MALDI MS. Though many methods have been attempted, we have discovered a significant publication history surrounding the use of nitrocellulose as a substrate to improve homogeneity of crystal formation and therefore reproducibility. We therefore propose that this is the most promising avenue of research for developing a comprehensive and universal preparation protocol for quantitative MALDI MS analysis. © 2016 Wiley Periodicals, Inc. Mass Spec Rev 37:217-228, 2018. © 2016 Wiley Periodicals, Inc.

  20. Reproducibility of tumor uptake heterogeneity characterization through textural feature analysis in 18F-FDG PET.

    Science.gov (United States)

    Tixier, Florent; Hatt, Mathieu; Le Rest, Catherine Cheze; Le Pogam, Adrien; Corcos, Laurent; Visvikis, Dimitris

    2012-05-01

    (18)F-FDG PET measurement of standardized uptake value (SUV) is increasingly used for monitoring therapy response and predicting outcome. Alternative parameters computed through textural analysis were recently proposed to quantify the heterogeneity of tracer uptake by tumors as a significant predictor of response. The primary objective of this study was to evaluate the reproducibility of these heterogeneity measurements. Double baseline (18)F-FDG PET scans were acquired within 4 d of each other for 16 patients before any treatment was considered. A Bland-Altman analysis was performed on 8 parameters based on histogram measurements and 17 parameters based on textural heterogeneity features after discretization with values between 8 and 128. The reproducibility of maximum and mean SUV was similar to that in previously reported studies, with a mean percentage difference of 4.7% ± 19.5% and 5.5% ± 21.2%, respectively. By comparison, better reproducibility was measured for some textural features describing local heterogeneity of tracer uptake, such as entropy and homogeneity, with a mean percentage difference of -2% ± 5.4% and 1.8% ± 11.5%, respectively. Several regional heterogeneity parameters such as variability in the intensity and size of regions of homogeneous activity distribution had reproducibility similar to that of SUV measurements, with 95% confidence intervals of -22.5% to 3.1% and -1.1% to 23.5%, respectively. These parameters were largely insensitive to the discretization range. Several parameters derived from textural analysis describing heterogeneity of tracer uptake by tumors on local and regional scales had reproducibility similar to or better than that of simple SUV measurements. These reproducibility results suggest that these (18)F-FDG PET-derived parameters, which have already been shown to have predictive and prognostic value in certain cancer models, may be used to monitor therapy response and predict patient outcome.