WorldWideScience

Sample records for structural building response

  1. Structural response of steel high rise buildings to fire

    DEFF Research Database (Denmark)

    Gentili, Filippo; Giuliani, Luisa; Bontempi, Franco

    2013-01-01

    Due to the significant vertical elevation and complexity of the structural system, high rise buildings may suffer from the effects of fire more than other structures. For this reason, in addition to evacuation strategies and active fire protection, a careful consideration of structural response t...

  2. Seismic Safety Margins Research Program (Phase I). Project IV. Structural building response; Structural Building Response Review

    International Nuclear Information System (INIS)

    Healey, J.J.; Wu, S.T.; Murga, M.

    1980-02-01

    As part of the Phase I effort of the Seismic Safety Margins Research Program (SSMRP) being performed by the University of California Lawrence Livermore Laboratory for the US Nuclear Regulatory Commission, the basic objective of Subtask IV.1 (Structural Building Response Review) is to review and summarize current methods and data pertaining to seismic response calculations particularly as they relate to the objectives of the SSMRP. This material forms one component in the development of the overall computational methodology involving state of the art computations including explicit consideration of uncertainty and aimed at ultimately deriving estimates of the probability of radioactive releases due to seismic effects on nuclear power plant facilities

  3. Seismic response analysis of an instrumented building structure

    Science.gov (United States)

    Li, H.-J.; Zhu, S.-Y.; Celebi, M.

    2003-01-01

    The Sheraton - Universal hotel, an instrumented building lying in North Hollywood, USA is selected for case study in this paper. The finite element method is used to produce a linear time - invariant structural model, and the SAP2000 program is employed for the time history analysis of the instrumented structure under the base excitation of strong motions recorded in the basement during the Northridge, California earthquake of 17 January 1994. The calculated structural responses are compared with the recorded data in both time domain and frequency domain, and the effects of structural parameters evaluation and indeterminate factors are discussed. Some features of structural response, such as the reason why the peak responses of acceleration in the ninth floor are larger than those in the sixteenth floor, are also explained.

  4. Structural building response review

    International Nuclear Information System (INIS)

    1980-01-01

    The integrity of a nuclear power plant during a postulated seismic event is required to protect the public against radiation. Therefore, a detailed set of seismic analyses of various structures and equipment is performed while designing a nuclear power plant. This report describes the structural response analysis method, including the structural model, soil-structure interaction as it relates to structural models, methods for seismic structural analysis, numerical integration methods, methods for non-seismic response analysis approaches for various response combinations, structural damping values, nonlinear response, uncertainties in structural properties, and structural response analysis using random properties. The report describes the state-of-the-art in these areas for nuclear power plants. It also details the past studies made at Sargent and Lundy to evaluate different alternatives and the conclusions reached for the specific purposes that those studies were intended. These results were incorporated here because they fall into the general scope of this report. The scope of the present task does not include performing new calculations

  5. Floor response spectra of buildings with uncertain structural properties

    International Nuclear Information System (INIS)

    Chen, P.C.

    1975-01-01

    All Category I equipment, such as reactors, vessels, and major piping systems of nuclear power plants, is required to withstand earthquake loadings in order to minimize risk of seismic damage. The equipment is designed by using response spectra of the floor on which the equipment is mounted. The floor response spectra are constructed usually from the floor response time histories which are obtained through a deterministic dynamic analysis. This analysis assumes that all structural parameters, such as mass, stiffness, and damping have been calculated precisely, and that the earthquakes are known. However, structural parameters are usually difficult to determine precisely if the structures are massive and/or irregular, such as nuclear containments and its internal structures with foundation soil incorporated into the analysis. Faced with these uncertainties, it has been the practice to broaden the floor response spectra peaks by +-10 percent of the peak frequencies on the basis of conservatism. This approach is based on engineering judgement and does not have an analytical basis to provide a sufficient level of confidence in using these spectra for equipment design. To insure reliable design, it is necessary to know structural response variations due to variations in structural properties. This consideration leads to the treatment of structural properties as random variables and the use of probabilistic methods to predict structural response more accurately. New results on floor response spectra of buildings with uncertain structural properties obtained by determining the probabilistic dynamic response from the deterministic dynamic response and its standard deviation are presented. The resulting probabilistic floor response spectra are compared with those obtained deterministically, and are shown to provide a more reliable method for determining seismic forces

  6. Structural impact response for assessing railway vibration induced on buildings

    Science.gov (United States)

    Kouroussis, Georges; Mouzakis, Harris P.; Vogiatzis, Konstantinos E.

    2018-03-01

    Over the syears, the rapid growth in railway infrastructure has led to numerous environmental challenges. One such significant issue, particularly in urban areas, is ground-borne vibration. A common source of ground-borne vibration is caused by local defects (e.g. rail joints, switches, turnouts, etc.) that generate large amplitude excitations at isolated locations. Modelling these excitation sources is particularly challenging and requires the use of complex and extensive computational efforts. For some situations, the use of experiments and measured data offers a rapid way to estimate the effect of such defects and to evaluate the railway vibration levels using a scoping approach. In this paper, the problem of railway-induced ground vibrations is presented along with experimental studies to assess the ground vibration and ground borne noise levels, with a particular focus on the structural response of sensitive buildings. The behaviour of particular building foundations is evaluated through experimental data collected in Brussels Region, by presenting the expected frequency responses for various types of buildings, taking into account both the soil-structure interaction and the tramway track response. A second study is dedicated to the Athens metro, where transmissibility functions are used to analyse the effect of various Athenian building face to metro network trough comprehensive measurement campaigns. This allows the verification of appropriate vibration mitigation measures. These benchmark applications based on experimental results have been proved to be efficient to treat a complex problem encountered in practice in urban areas, where the urban rail network interacts with important local defects and where the rise of railway ground vibration problems has clearly been identified.

  7. Ambient Response Analysis of the Heritage Court Tower Building Structure

    DEFF Research Database (Denmark)

    Brincker, Rune; Andersen, Palle

    2000-01-01

    In this paper an ambient response analysis of the Heritage Court Building structure is presented. The work is a part of a blind test organized by Professor Carlos Ventura, University of British Columbia. The response data were analyses using two different techniques: a non-parametric based on Fre...... modes, natural frequencies identified by the two techniques shoved good agreement, mode shape estimates were nearly identical, and damping ratios reasonably close and around 1-2% in the most cases....

  8. Ambient Response Analysis of the Heritage Court Tower Building Structure

    DEFF Research Database (Denmark)

    Brincker, Rune; Andersen, Palle

    2000-01-01

    In this paper an ambient response analysis of the Heritage Court Building structure is presented. The work is a part of a blind test organized by Professor Carlos Ventura, University of British Columbia. The response data were analyses using two different techniques: a non-parametric based...... modes, natural frequencies identified by the two techniques shoved good agreement, mode shape estimates were nearly identical, and damping ratios reasonably close and around 1-2% in the most cases....

  9. Analysis of soil-structure interaction and floor response spectrum of reactor building for China advanced research reactor

    International Nuclear Information System (INIS)

    Rong Feng; Wang Jiachun; He Shuyan

    2006-01-01

    Analysis of Soil-Structure Interaction (SSI) and calculation of Floor Response Spectrum (FRS) is substantial for anti-seismic design for China Advanced Research Reactor (CARR) project. The article uses direct method to analyze the seismic reaction of the reactor building in considering soil-structure interaction by establishing two-dimensional soil-structure co-acting model for analyzing and inputting of seismic waves from three directions respectively. The seismic response and floor response spectrum of foundation and floors of the building under different cases have been calculated. (authors)

  10. Intelligent seismic risk mitigation system on structure building

    Science.gov (United States)

    Suryanita, R.; Maizir, H.; Yuniorto, E.; Jingga, H.

    2018-01-01

    Indonesia located on the Pacific Ring of Fire, is one of the highest-risk seismic zone in the world. The strong ground motion might cause catastrophic collapse of the building which leads to casualties and property damages. Therefore, it is imperative to properly design the structural response of building against seismic hazard. Seismic-resistant building design process requires structural analysis to be performed to obtain the necessary building responses. However, the structural analysis could be very difficult and time consuming. This study aims to predict the structural response includes displacement, velocity, and acceleration of multi-storey building with the fixed floor plan using Artificial Neural Network (ANN) method based on the 2010 Indonesian seismic hazard map. By varying the building height, soil condition, and seismic location in 47 cities in Indonesia, 6345 data sets were obtained and fed into the ANN model for the learning process. The trained ANN can predict the displacement, velocity, and acceleration responses with up to 96% of predicted rate. The trained ANN architecture and weight factors were later used to build a simple tool in Visual Basic program which possesses the features for prediction of structural response as mentioned previously.

  11. Evaluation of Seismic Response Trends from Long-Term Monitoring of Two Instrumented RC Buildings Including Soil-Structure Interaction

    Directory of Open Access Journals (Sweden)

    Faheem Butt

    2012-01-01

    Full Text Available This paper presents analyses of the seismic responses of two reinforced concrete buildings monitored for a period of more than two years. One of the structures was a three-storey reinforced concrete (RC frame building with a shear core, while the other was a three-storey RC frame building without a core. Both buildings are part of the same large complex but are seismically separated from the rest of it. Statistical analysis of the relationships between maximum free field accelerations and responses at different points on the buildings was conducted and demonstrated strong correlation between those. System identification studies using recorded accelerations were undertaken and revealed that natural frequencies and damping ratios of the building structures vary during different earthquake excitations. This variation was statistically examined and relationships between identified natural frequencies and damping ratios, and the peak response acceleration at the roof level were developed. A general trend of decreasing modal frequencies and increasing damping ratios was observed with increased level of shaking and response. Moreover, the influence of soil structure interaction (SSI on the modal characteristics was evaluated. SSI effects decreased the modal frequencies and increased some of the damping ratios.

  12. Structural response of Paks NPP WWER-440 MW main building complex to blast input motion. Final report

    International Nuclear Information System (INIS)

    1999-01-01

    The Soviet standard design units WWER-440/213 type installed in Paks NPP were not originally designed for a Safe Shutdown Earthquake. At the time of selection of Paks site on the basis of historical earthquake data was supposed that the maximum earthquake is of grade V according MSK-64 scale. This seismicity level had not required any special measures to account for seismic event effects on the Main Building Complex Structure. Current site seismicity studies reveal that the seismic hazard for the site significantly exceeds the originally estimated. In addition the safety rules and seismic code requirements became more rugged. As a part of the activities to increase the seismic safety of the Paks NPP the study on dynamic behaviour of the Main Building Complex Structure has been performed with support of IAEA. The explosion full scale tests were carried out for determining the dynamic behaviour of the structure and for assessment of the Soil Structure Interaction (SSI) effects in the modelling and analysis procedures, used in the dynamic response analyses. The objective of the project was to evaluate the blast response of the WWER-440/213 Main Building Complex at Paks NPP, based on the data available for the soil properties, recorded free-field blast input motion, and structural design. The scope of EQE-Bulgaria study was to conduct a state-of-the-art SSI analysis with a multiple foundations supported model of the Main Building Complex to assess the structure blast response. The analysis was focused on a modelling technique that assess realistically the SSI effects on the dynamic response of a structure supported on multiple foundation instead of simplified, but more conservative techniques. The scope of research was covered splitting the study into the following steps: development of a twin units model for Main Building Complex structure; development of a Low Strain Soil Properties Model; development of SSI Parameters consisting of a Multiple Foundations System

  13. Towards smart building structures : adaptive structures in earthquake and wind loading control response – a review

    NARCIS (Netherlands)

    Morales-Beltran, M.; Teuffel, P.M.

    2013-01-01

    This article is a review about applications for non-passive control response of buildings (namely active, hybrid and semi-active systems), wherein the degree of integration between control devices and structural system is explored. The purpose is to establish the current state-of-the-art in the

  14. Verification of the local structural response of building structures in the anchorage areas of heavy components

    International Nuclear Information System (INIS)

    Krutzik, N.J.; Tropp, R.

    1989-01-01

    In conventional dynamic structural analyses for determining dynamic system response for various locations at which components are installed inside the structures it is common practice (in order to simplify analytical effort) to assume that the anchorage (anchor plate, anchor bolts or throughbolts, concrete and reinforcement in the area of bound) has rigid body characteristics and that the building structure itself does not display any local response of its own. The influence of the stiffness of the anchor plate as well anchor bolts and its stress level on the dynamic response is also neglected. For a large number of anchoring systems, especially for all those components and systems having only a small mass, this assumption is certainly appropriate. At some locations, particularly at points where heavy components are anchored or when loading input has been increased, this can lead to local loading of the anchor system as well as of the building structure well into the nonlinear range. Often, verification of capability to accommodate these loads is not possible without changing the wall thicknesses or increasing the percentage of reinforcement. Since the presence of linear or nonlinear effects can be expected to result in energy dissipation (increase in damping capacity and also a change in the stiffness of the coupled system) it must be assumed that the dynamic response between the theoretical coupling point A and the real connection point B of the component on the anchor plate can be considerably altered. Some changes of the dynamic response in the connection point B have to be expected generally even in cases of linear-elastic loading of the anchorage. Using typical anchoring systems as an example, the influence of consideration of nonlinear effects in the anchorage area of a typical anchor plate on the dynamic response as well as the conservatism of conventional analytical approaches are investigated

  15. Floor Response Spectra of Nuclear Containment Building with Soil-Structure Interaction

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Choon Gyo; Ryu, Jeong Soo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-10-15

    This paper presents a seismic analysis technique for a 3D soil-structure interaction(SSI) system in frequency domain, based on the finite element formulation incorporating frequency-dependent dynamic infinite elements for the far field soil region. Earthquake input motions are regarded as traveling SV-wave which is vertically incident from a far-field soil region. In which, the equivalent earthquake forces in the frequency domain are calculated using the exterior rigid boundary method and the free field response analysis. For the application, floor response spectra analyses for nuclear containment building on a soil medium is carried out, the obtained results are compared with the free field response by other solution.

  16. Determination of the NPP Cernavoda reactor building seismic response

    International Nuclear Information System (INIS)

    Krutzik, N.J.; Rotaru, I.; Bobei, M.; Mingiuc, C.; Serban, V.

    1997-01-01

    Seismic input for systems and equipment installed in buildings depends on: - the seismic movement in free field on site; - the building movement in the soil; - the building deflection. The percentage of the 3 movements for the system and equipment input, depends on the position of the systems and equipment inside the building as well on the type of the foundation soil. The type of the foundation soil is important because if it is stiff it transfers a lot of energy to the building, energy which amplify the movement of the building on the top. If the foundation soil is soft, it accommodates the overall movement of the building in the soil, amplifying the movement to lower levels and the building response is attenuated if a resonance phenomenon between the whole building movement and the seismic excitation does not exist. This input is given with the design floor response spectra (FRS), in the logarithmic scale and seismic anchor movement (SAM). The design floor response spectra for NPP Cernavoda U1 Nuclear Building were determined in several stages starting with simple models (STICK type) without twisting movement and ending with detailed 3-dimensional models. From the point of view of dynamic behavior, the Reactor Building can be considered to be made up of 4 sub-structures: the containment building, internal structures containing separate elements such as the reactor vault, the fuel transfer structure and itself. Each sub-structure has its own movement (some of the structures present also some local effects) which combines with the overall movement of the building in the soil and the seismic excitation produce the total movement so that the response spectrum for each point of the sub-structure is specific. One should note that for structures which also show the twisting effect, the selection of the points on the floor, for the determination on the response spectra, is an engineering decision so that the response should be relevant for the equipment installed on the

  17. Verification of the local structural response of building structures in the anchorage areas of heavy components

    International Nuclear Information System (INIS)

    Krutzik, N.J.; Tropp, R.

    1993-01-01

    In both nuclear and non-nuclear areas of power plants, sections of structures, parts of systems and components are attached to walls and floors by means of anchor plates with bolts, anchor sleeves and bolts and through bolts arranged either in groups or individually. In order to simplify the determination of the transfered vibrations induced by external events (e.g. earthquake, aircraft crash), it is normally assumed that the nodal point between component and concrete possesses rigid body characteristics and the building structure (walls, floors) is also inflexible in the anchorage area. In the course of the parametric studies performed, the nonlinear effects on the anchorage area of a component (in this case an anchor plate and concrete slab) were calculated and the effect of these on the actual vibration behavior and the local structural responses of the building structure at the place of installation of heavy components were investigated. The investigations performed reveal that by taking into account the local behaviour in the anchoring point, it is possible to reduce the dynamic response considerably. More detailed examination of the influence of additional parameters (especially of the geometry of the anchor plates and anchor bolts and their material characteristics) will require further investigations aimed at establishing the characteristics of typical anchor plates. (orig.)

  18. Earthquake response analysis of embedded reactor building considering soil-structure separation and nonlinearity of soil

    International Nuclear Information System (INIS)

    Ichikawa, T.; Hayashi, Y.; Nakai, S.

    1987-01-01

    In the earthquake response analysis for a rigid and massive structure as a nuclear reactor building, it is important to estimate the effect of soil-structure interaction (SSI) appropriately. In case of strong earthquakes, the nonlinearity, such as the wall-ground separation, the base mat uplift of sliding, makes the behavior of the soil-structure system complex. But, if the nuclear reactor building is embedded in a relatively soft ground with surface layer, the wall-ground separation plays the most important role in the response of soil-structure system. Because, it is expected that the base uplift and slide would be less significant due to the effect of the embedment, and the wall-ground friction is usually neglected in design. But, the nonlinearity of ground may have some effect on the wall-ground separation and the response of the structure. These problems have been studied by use of FEM. Others used joint elements between the ground and the structure which does not resist tensile force. Others studied the effect of wall-ground separation with non-tension springs. But the relationship between the ground condition and the effect of the separation has not been clarified yet. To clarify the effect the analyses by FE model and lumped mass model (sway-rocking model) are performed and compared. The key parameter is the ground profile, namely the stiffness of the side soil

  19. SSI response of a typical shear wall structure. Appendix B. In-structure response spectra comparisons. Volume 2

    International Nuclear Information System (INIS)

    Johnson, J.J.; Schewe, E.C.; Maslenikov, O.R.

    1984-04-01

    The objectives of this study were two-fold: (1) develop building response calibration factors, i.e., factors which relate best estimate or median level response to responses calculated by selected design procedures. Soil-structure interaction was the phenomenon of interest because significant simplifications are frequently introduced in its treatment; and (2) the second objective can be viewed in the context of a question: what effect does placing an identical structure on different sites and with different foundation conditions have on structure response. The structure selected for this study is a part of the Zion AFT complex. Only the auxiliary, fuel-handling, and diesel generator buildings were studied. This structure is a connected group of shear-wall buildings constructed of reinforced concrete, typical of nuclear power plant structures. The bases of comparison for this study were structure responses: peak in-structure accelerations (27 components), and peak wall forces and moments (111 components). In-structure response spectra were also considered. This appendix contains in-structure response spectra comparisons in detail

  20. Shape Control of Responsive Building Envelopes

    DEFF Research Database (Denmark)

    Foged, Isak Worre; Kirkegaard, Poul Henning; Christensen, Jesper Thøger

    2010-01-01

    The present paper considers shape control of adaptive architectural structures for improvement of structural performance by recognizing changes in their environments and loads, adapting to meet goals, and using past events to improve future performance or maintain serviceability. The general scop...... environmental system to a primary structural system joint into a collective behavioral system equipment with an actuator system is presented....... alternatives. The adaptive structure is a proposal for a responsive building envelope which is an idea of a first level operational framework for present and future investigations towards performance based responsive architectures through a set of responsive typologies. A mock-up concept of a secondary...

  1. Modeling of the structural response to fire of a high-rise steel building

    DEFF Research Database (Denmark)

    Gentili, Filippo; Giuliani, Luisa; Bontempi, Franco

    2011-01-01

    Observations from the tests and the real fire investigations have consistently shown that the performance of a whole steel-framed building in fire is very different from the performance of its individual members (Usmani et al, 2000). In this context, it is of interest to investigate the failures...... problems due to the triggering of local mechanism should be overcome to this purpose. In this paper, a steel structure has been considered as case study and the response of the structural system to fire and fire effects has been investigated with the avail of a finite element commercial code. These kinds...

  2. Soil Structure Interaction Effect on High Rise and Low Rise Buildings

    OpenAIRE

    Divya Pathak; PAresh H. SHAH

    2000-01-01

    Effect of supporting soil on the response of structure has been analyzed in the present study. A low rise (G+ 5 storey) and a high rise (G+12 storey) building has been taken for the analysis. For both type of buildings, the response of building with and without consideration of soil structure interaction effect has been compared.Without interaction case is the case in which ends of the structure are assumed to be fixed while in interaction case, structure is assumed to be...

  3. Response characteristics of reactor building on weathered soft rock ground

    International Nuclear Information System (INIS)

    Hirata, Kazuta; Tochigi, Hitoshi

    1991-01-01

    The purpose of this study is to investigate the seismic stability of nuclear power plants on layered soft bedrock grounds, focusing on the seismic response of reactor buildings. In this case, the soft bedrock grounds refer to the weathered soft bedrocks with several tens meter thickness overlaying hard bedrocks. Under this condition, there are two subjects regarding the estimation of the seismic response of reactor buildings. One is the estimation of the seismic response of surface ground, and another is the estimation of soil-structure interaction characteristics for the structures embedded in the layered grounds with low impedandce ratio between the surface ground and the bedrock. Paying attention to these subjects, many cases of seismic response analysis were carried out, and the following facts were clarified. In the soft rock grounds overlaying hard bedrocks, it was proved that the response acceleration was larger than the case of uniform hard bedrocks. A simplified sway and rocking model was proposed to consider soil-structure interaction. It was proved that the response of reactor buildings was small when the effect of embedment was considered. (K.I.)

  4. Radar Mapping of Building Structures Applying Sparse Reconstruction

    NARCIS (Netherlands)

    Tan, R.G.; Wit, J.J.M. de; Rossum, W.L. van

    2012-01-01

    The ability to map building structures at a certain stand-off distance allows intelligence, reconnaissance, and clearance tasks to be performed in a covert way by driving around a building. This will greatly improve security, response time, and reliability of aforementioned tasks. Therefore,

  5. Before and after retrofit - response of a building during ambient and strong motions

    Science.gov (United States)

    Celebi, M.; Liu, Huaibao P.; ,

    1998-01-01

    This paper presents results obtained from ambient vibration and strong-motion responses of a thirteen-story, moment-resisting steel framed Santa Clara County Office Building (SCCOB) before being retrofitted by visco-elastic dampers and from ambient vibration response following the retrofit. Understanding the cumulative structural and site characteristics that affect the response of SCCOB before and after the retrofit is important in assessing earthquake hazards to other similar buildings and decision making in retrofitting them. The results emphasize the need to better evaluate structural and site characteristics in developing earthquake resisting designs that avoid resonating effects. Various studies of the strong-motion response records from the SCCOB during the 24 April 1984 (MHE) Morgan Hill (MS = 6.1), the 31 March 1986 (MLE) Mt. Lewis (MS = 6.1) and the 17 October 1989 (LPE) Loma Prieta (MS = 7.1) earthquakes show that the dynamic characteristics of the building are such that it (a) resonated (b) responded with a beating effect due to close-coupling of its translational and torsional frequencies, and (c) had a long-duration response due to low-damping. During each of these earthquakes, there was considerable contents damage and the occupants felt the rigorous vibration of the building. Ambient tests of SCCOB performed following LPE showed that both translational and torsional periods of the building are smaller than those derived from strong motions. Ambient tests performed following the retrofit of the building with visco-elastic dampers show that the structural fundamental mode frequency of the building has increased. The increased frequency implies a stiffer structure. Strong-motion response of the building during future earthquakes will ultimately validate the effectiveness of the retrofit method.This paper presents results obtained from ambient vibration and strong-motion responses of a thirteen-story, moment-resisting steel framed Santa Clara County

  6. Modern frame structure buildings

    Directory of Open Access Journals (Sweden)

    В. М. Першаков

    2013-07-01

    Full Text Available The article deals with the design, construction and implementation of reinforced concrete frame structures with span 18, 21 m for agricultural production buildings, hall-premises of public buildings and buildings of agricultural aviation. Structures are prefabricated frame buildings and have such advantages as large space inside the structure and lower cost compared with other facilities with same purpose

  7. Earthquake response analysis of a base isolated building

    International Nuclear Information System (INIS)

    Mazda, T.; Shiojiri, H.; Sawada, Y.; Harada, O.; Kawai, N.; Ontsuka, S.

    1989-01-01

    Recently, the seismic isolation has become one of the popular methods in the design of important structures or equipments against the earthquakes. However, it is desired to accumulate the demonstration data on reliability of seismically isolated structures and to establish the analysis methods of those structures. Based on the above recognition, the vibration tests of a base isolated building were carried out in Tsukuba Science City. After that, many earthquake records have been obtained at the building. In order to examine the validity of numerical models, earthquake response analyses have been executed by using both lumped mass model, and finite element model

  8. The Growing Awareness Inventory: Building Capacity for Culturally Responsive Science and Mathematics with a Structured Observation Protocol

    Science.gov (United States)

    Brown, Julie C.; Crippen, Kent J.

    2016-01-01

    This study represents a first iteration in the design process of the Growing Awareness Inventory (GAIn), a structured observation protocol for building the awareness of preservice teachers (PSTs) for resources in mathematics and science classrooms that can be used for culturally responsive pedagogy (CRP). The GAIn is designed to develop awareness…

  9. Transactive Control of Commercial Buildings for Demand Response

    Energy Technology Data Exchange (ETDEWEB)

    Hao, He; Corbin, Charles D.; Kalsi, Karanjit; Pratt, Robert G.

    2017-01-01

    Transactive control is a type of distributed control strategy that uses market mechanism to engage self-interested responsive loads to achieve power balance in the electrical power grid. In this paper, we propose a transactive control approach of commercial building Heating, Ventilation, and Air- Conditioning (HVAC) systems for demand response. We first describe the system models, and identify their model parameters using data collected from Systems Engineering Building (SEB) located on our Pacific Northwest National Laboratory (PNNL) campus. We next present a transactive control market structure for commercial building HVAC system, and describe its agent bidding and market clearing strategies. Several case studies are performed in a simulation environment using Building Control Virtual Test Bed (BCVTB) and calibrated SEB EnergyPlus model. We show that the proposed transactive control approach is very effective at peak clipping, load shifting, and strategic conservation for commercial building HVAC systems.

  10. Integrating Responsive Building Elements in Buildings

    DEFF Research Database (Denmark)

    Haase, Matthias; Amato, Alex; Heiselberg, Per

    2006-01-01

    energy strategies to develop guidelines and procedures for estimation of environmental performance of responsive building elements and integrated building concepts This paper introduces the ideas of this collaborative work and discusses its usefulness for Hong Kong and China. Special focus was put...

  11. Seismic response of reactor building on alluvial soil by direct implicit integration

    International Nuclear Information System (INIS)

    Thakkar, S.K.; Dinkar, A.K.

    1983-01-01

    The evaluation of seismic response of a reactor building is a complex problem. A study has been made in this paper of seismic response of a reactor building by direct implicit integration method. The direct implicit integration methods besides being unconditionally stable have the merit of including response of higher modes without much effort. A reactor building consisting of external shell, internal shell, internals and raft is considered to be resting on alluvium. The complete building including the foundation is idealized by axisymmetric finite elements. The structure is analyzed separately for horizontal and vertical components of ground motion using harmonic analysis. Total response is found by superposition of two responses. The variation of several parameters, such as soil stiffness, embedment depth, inertia of foundation, viscous boundary and damping on seismic response is studied. The structural response is seen to depend significantly on the soil stiffness and damping. The seismic response is observed to be less sensitive to embedment depth and inertia of foundation. The vertical accelerations on the raft, boiler room floor slab and dome due to vertical ground motions are quite appreciable. The viscous boundary is seen to alter structural response in significantly compared to rigid boundaries in a larger mesh and its use appears to be promising in absorbing energy of body waves when used with direct implicit integration method. (orig.)

  12. Seismic Response of Steel Braced Building Frame Considering Soil Structure Interaction (SSI): An Experimental Study

    Science.gov (United States)

    Hirave, Vivek; Kalyanshetti, Mahesh

    2018-02-01

    Conventional fixed-base analysis ignoring the effect of soil-flexibility may result in unsafe design. Therefore, to evaluate the realistic behavior of structure the soil structure interaction (SSI) effect shall be incorporated in the analysis. In seismic analysis, provision of bracing system is one of the important option for the structure to have sufficient strength with adequate stiffness to resist lateral forces. The different configuration of these bracing systems alters the response of buildings, and therefore, it is important to evaluate the most effective bracing systems in view point of stability against SSI effect. In present study, three RC building frames, G+3, G+5 and G+7 and their respective scaled down steel model with two types of steel bracing system incorporating the effect of soil flexibility is considered for experimental and analytical study. The analytical study is carried out using Elastic continuum approach and the experimental study is carried out using Shake Table. The influence of SSI on various seismic parameters is presented. The study reveals that, steel bracing system is beneficial to control SSI effect and it is observed that V bracing is more effective, in resisting seismic load considering SSI.

  13. Calculation methods of Structure-Soil-Structure Interaction (3SI) for embedded buildings: Application to NUPEC tests

    International Nuclear Information System (INIS)

    Clouteau, D.; Broc, D.; Devesa, G.; Guyonvarh, V.; Massin, P.

    2012-01-01

    This work aims at improving and validating methods coupling Finite Element (FE) and Boundary Element (BE) Methods in the context of Soil-Structure Interaction (SSI) and Structure-Soil-Structure Interaction (3SI) tests performed by NUPEC on mock-up structures built on an unmade ground. Several cases have been tested: single and juxtaposed buildings, shallow and embedded foundations, with various loading conditions: forced and natural seismic loadings. The numerical simulations of forced vibration tests are in good agreement with the results of the NUPEC experiments in the case of two embedded buildings either in terms of amplitude and resonance. The numerical simulation of seismic response tests by FEM and BEM allows for a proper choice of the 'reference point' where the computed and the experimental displacements coincide. A parametric analysis of Structure-Soil-Structure Interaction carried out by the FEM has allowed to determine the influence of some parameters on SSI. Most of them like the position of the building in the excavation, the direction of the load, the quality of the contact between the sidewalls of the buildings and the soil for embedded foundations, do not show to have a strong influence on the dynamic system behaviour, which is mainly governed by the stiffness of the first soil layer. As far as 3SI is concerned, this paper shows that when the cross interaction has a small effect on the building response in the case of surface foundations, it has a strong influence in the case of embedded foundations with an important decrease of the response at the top of the buildings. (authors)

  14. Assessment of seismic design response factors of concrete wall buildings

    Science.gov (United States)

    Mwafy, Aman

    2011-03-01

    To verify the seismic design response factors of high-rise buildings, five reference structures, varying in height from 20- to 60-stories, were selected and designed according to modern design codes to represent a wide range of concrete wall structures. Verified fiber-based analytical models for inelastic simulation were developed, considering the geometric nonlinearity and material inelasticity of the structural members. The ground motion uncertainty was accounted for by employing 20 earthquake records representing two seismic scenarios, consistent with the latest understanding of the tectonic setting and seismicity of the selected reference region (UAE). A large number of Inelastic Pushover Analyses (IPAs) and Incremental Dynamic Collapse Analyses (IDCAs) were deployed for the reference structures to estimate the seismic design response factors. It is concluded that the factors adopted by the design code are adequately conservative. The results of this systematic assessment of seismic design response factors apply to a wide variety of contemporary concrete wall buildings with various characteristics.

  15. Seismic response of transamerical building. I. Data and preliminary analysis

    Science.gov (United States)

    Celebi, M.; Safak, E.

    1991-01-01

    The objective of this paper is to present preliminary analyses of a set of acceleration response records obtained during the October 17, 1989 Loma Prieta earthquake (Ms = 7.1) from the 60-story vertically tapered, pyramid-shaped Trans-america Building-a landmark of San Francisco. The building was instrumented in 1985 with 22 channels of synchronized sensors consisting of 13 uniaxial accelerometers deployed throughout the structure and connected to a central recording system and three triaxial strong-motion accelerographs at three different levels of the structure. No free-field accelerographs are at the site. The acceleration records permit the study of the behavior of this unique structure. The predominant translational response of the building and the associated frequency at approximately 0.28 Hz are identified from the records and their Fourier amplitude spectra. The records do not indicate any significant torsional motion. However, there is rocking type soil-structure interaction, and an associated frequency of approximately 2.0 Hz is identified from the Fourier amplitude spectra of the differential motions between the ground level and that at the basement. In addition, the response spectra for the basement motions indicate significant resonance in both directions at a period of approximately 0.5 seconds.

  16. Earthquake Response of Reinforced Concrete Building Retrofitted with Geopolymer Concrete and X-shaped Metallic Damper

    Science.gov (United States)

    Madheswaran, C. K.; Prakash vel, J.; Sathishkumar, K.; Rao, G. V. Rama

    2017-06-01

    A three-storey half scale reinforced concrete (RC) building is fixed with X-shaped metallic damper at the ground floor level, is designed and fabricated to study its seismic response characteristics. Experimental studies are carried out using the (4 m × 4 m) tri-axial shake-table facility to evaluate the seismic response of a retrofitted RC building with open ground storey (OGS) structure using yielding type X-shaped metallic dampers (also called as Added Damping and Stiffness-ADAS elements) and repairing the damaged ground storey columns using geopolymer concrete composites. This elasto-plastic device is normally incorporated within the frame structure between adjacent floors through chevron bracing, so that they efficiently enhance the overall energy dissipation ability of the seismically deficient frame structure under earthquake loading. Free vibration tests on RC building without and with yielding type X-shaped metallic damper is carried out. The natural frequencies and mode shapes of RC building without and with yielding type X-shaped metallic damper are determined. The retrofitted reinforced concrete building is subjected to earthquake excitations and the response from the structure is recorded. This work discusses the preparation of test specimen, experimental set-up, instrumentation, method of testing of RC building and the response of the structure. The metallic damper reduces the time period of the structure and displacement demands on the OGS columns of the structure. Nonlinear time history analysis is performed using structural analysis package, SAP2000.

  17. Novel transformation-based response prediction of shear building ...

    Indian Academy of Sciences (India)

    c Indian Academy of Sciences ... structural response of multi-storey shear buildings subject to earthquake motion. The INN is first ... China has been presented by Xie et al. (2011). ... research works have been done using INN in other fields.

  18. FRF-based structural damage detection of controlled buildings with podium structures: Experimental investigation

    Science.gov (United States)

    Xu, Y. L.; Huang, Q.; Zhan, S.; Su, Z. Q.; Liu, H. J.

    2014-06-01

    How to use control devices to enhance system identification and damage detection in relation to a structure that requires both vibration control and structural health monitoring is an interesting yet practical topic. In this study, the possibility of using the added stiffness provided by control devices and frequency response functions (FRFs) to detect damage in a building complex was explored experimentally. Scale models of a 12-storey main building and a 3-storey podium structure were built to represent a building complex. Given that the connection between the main building and the podium structure is most susceptible to damage, damage to the building complex was experimentally simulated by changing the connection stiffness. To simulate the added stiffness provided by a semi-active friction damper, a steel circular ring was designed and used to add the related stiffness to the building complex. By varying the connection stiffness using an eccentric wheel excitation system and by adding or not adding the circular ring, eight cases were investigated and eight sets of FRFs were measured. The experimental results were used to detect damage (changes in connection stiffness) using a recently proposed FRF-based damage detection method. The experimental results showed that the FRF-based damage detection method could satisfactorily locate and quantify damage.

  19. Nonlinear seismic response analysis of an embedded reactor building based on the substructure approach

    International Nuclear Information System (INIS)

    Hasegawa, M.; Ichikawa, T.; Nakai, S.; Watanabe, T.

    1987-01-01

    A practical method to calculate the elasto-plastic seismic response of structures considering the dynamic soil-structure interaction is presented. The substructure technique in the time domain is utilized in the proposed method. A simple soil spring system with the coupling effects which are usually evaluated by the impedance matrix is introduced to consider the soil-structure interaction for embedded structures. As a numerical example, the response of a BWR-MARK II type reactor building embedded in the layered soil is calculated. The accuracy of the present method is verified by comparing its numerical results with exact solutions. The nonlinear behaivor and the soil-structure interaction effects on the response of the reactor building are also discussed in detail. It is concluded that the present method is effective for the aseismic design considering both the material nonlinearity of the nuclear reactor building and the dynamic soil-structure interaction. (orig.)

  20. The Structure of Affine Buildings

    CERN Document Server

    Weiss, Richard M

    2009-01-01

    In The Structure of Affine Buildings, Richard Weiss gives a detailed presentation of the complete proof of the classification of Bruhat-Tits buildings first completed by Jacques Tits in 1986. The book includes numerous results about automorphisms, completions, and residues of these buildings. It also includes tables correlating the results in the locally finite case with the results of Tits's classification of absolutely simple algebraic groups defined over a local field. A companion to Weiss's The Structure of Spherical Buildings, The Structure of Affine Buildings is organized around the clas

  1. Earthquake response analysis considering structure-soil-structure interaction

    International Nuclear Information System (INIS)

    Shiomi, T.; Takahashi, K.; Oguro, E.

    1981-01-01

    This paper proposes a numerical method of earthquake response analysis considering the structure-soil-structure interaction between two adjacent buildings. In this paper an analytical study is presented in order to show some typical features of coupling effects of two reactor buildings of the BWR-type nuclear power plant. The technical approach is a kind of substructure method, which at first evaluates the compliance properties with the foundation-soil-foundation interaction and then uses the compliance in determining seismic responses of two super-structures during earthquake motions. For this purpose, it is assumed that the soil medium is an elastic half space for modeling and that the rigidity of any type of structures such as piping facilities connecting the adjacent buildings is negligible. The technical approach is mainly based on the following procedures. Supersturcture stiffness is calculated by using the method which has been developed in our laboratory based on the Thin-Wall Beam Theory. Soil stiffness is expressed by a matrix with 12 x 12 elements as a function of frequency, which is calculated using the soil compliance functions proposed in Dr. Tajimi's Theory. These stiffness values may be expressed by complex numbers for modeling the damping mechanism of superstructures. We can solve eigenvalue problems with frequency dependent stiffness and the large-scale matrix using our method which is based on condensing the matrix to the suitable size by Rayleigh-Ritz method. Earthquake responses can be solved in the frequency domain by Fourier Transform. (orig./RW)

  2. SSI response of a typical shear wall structure

    International Nuclear Information System (INIS)

    Johnson, J.J.; Maslenikov, O.R.; Schewe, E.C.

    1985-01-01

    The seismic response of a typical shear structure in a commercial nuclear power plant was investigated for a series of site and foundation conditions using best estimate and design procedures. The structure selected is a part of the Zion AFT complex which is a connected group of reinforced concrete shear wall buildings, typical of nuclear power plant structures. Comparisons between best estimate responses quantified the effects of placing the structure on different sites and founding it in different manners. Calibration factors were developed by comparing simplified SSI design procedure responses to responses calculated by best estimate procedures. Nineteen basic cases were analyzed - each case was analyzed for ten earthquakes targeted to the NRC R.G. 1.60 design response spectra. The structure is a part of the Zion auxiliary-fuel handling turbine building (AFT) complex to the Zion nuclear power plants. (orig./HP)

  3. The seismic response and floor spectra of OL3 NPP buildings in Finland

    International Nuclear Information System (INIS)

    Pentti Varpasuo

    2005-01-01

    The purpose of the present work is the computation of seismic response and floor spectra of the nuclear power plant OL3 buildings in Olkiluoto. The following OL3 plant buildings were included in the analysis: 1. the Reactor Building UJA/UJB; 2. the Safeguard Buildings UJH/UJK 1-4; 3. and the Fuel Building UFA The in-structure spectra were generated using the ground motion response spectra documented in YVL GUIDE 2.6 'Seismic events at nuclear power plants' issued by Finnish Centre of Radiation Protection. The floor spectra were computed for the following equipment damping values: 2%, 4%, 7%, and 10%. The joint model for the plant buildings was generated. All analyses were linear and the direct time integration method was used with time step of 0.001 sec. All response runs were carried out with MSC/Nastran general purpose structural analysis program. The development of floor spectra has been carried out in accordance with the US NRC -Regulatory Guide 1.122: 'Development of Floor Design Response Spectra for Seismic Design of Floor-Supported Equipment or Components'. The response results show that the dominant frequencies of the reactor building are located around 5 Hz in frequency space and that the typical amplification of spectral peaks for 4% damping is from 8 -10 times when compared to peak ground acceleration. (authors)

  4. A Simple Response Evaluation Method for Base-Isolation Building-Connection Hybrid Structural System under Long-Period and Long-Duration Ground Motion

    Directory of Open Access Journals (Sweden)

    Kohei Hayashi

    2018-02-01

    Full Text Available An innovative hybrid control building system of base-isolation and building-connection has been proposed in the previous study. This system has two advantages, (i to resist an impulsive earthquake input through the base-isolation system and (ii to withstand a long-duration earthquake input through the building-connection system. A simple response evaluation method without the need of non-linear time–history response analysis is proposed here for this hybrid building system under a long-period and long-duration ground motion. An analytical expression is derived in the plastic deformation of an elastic–perfectly plastic single-degree-of-freedom (SDOF model with viscous damping under the multi-impulse, which is the representative of long-period and long-duration ground motions. A transformation procedure of a base-isolation building-connection hybrid structural system into an SDOF model is proposed by introducing two steps, one is the reduction of the main base-isolated building to an SDOF system, and the other is the reduction of the connecting oil dampers supported on a free-wall to an oil damper with a newly introduced compensation factor on a rigid wall. Application of the analytical expression of the plastic deformation to the reduced SDOF model including the compensation factor on the connecting oil dampers enables the development of a simplified, but rather accurate response evaluation method. The time–history response analysis of the multi-degree-of-freedom model and the comparison with the proposed simplified formula make clear the accuracy and reliability of the proposed simplified response evaluation method.

  5. Statistical uncertainty of response characteristic of building-appendage system for spectrum-compatible artificial earthquake motion

    International Nuclear Information System (INIS)

    Kurosaki, A.; Kozeki, M.

    1981-01-01

    Spectrum-compatible artificial time histories of ground motions are frequently used for the seismic design of nuclear power plant structures and components. However, statistical uncertainty of the responses of building structures and mechanical components mounted on the building (building-appendage systems) are anticipated, since an artificial time history is no more than one sample from a population of such time histories that match a specified design response spectrum. This uncertainty may spoil the reliability of the seismic design and therefore the extent of the uncertainty of the response characteristic is a matter of great concern. In this paper, above-mentioned uncertainty of the dynamic response characteristics of the building-appendage system to the spectrum-compatible artificial earthquake is investigated. (orig./RW)

  6. Earthquake response observation of isolated buildings

    International Nuclear Information System (INIS)

    Harada, O.; Kawai, N.; Ishii, T.; Sawada, Y.; Shiojiri, H.; Mazda, T.

    1989-01-01

    Base isolation system is expected to be a technology for a rational design of FBR plant. In order to apply this system to important structures, accumulation of verification data is necessary. From this point of view, the vibration test and the earthquake response observation of the actual isolated building using laminated rubber bearings and elasto-plastic steel dampers were conducted for the purpose of investigating its dynamic behavior and of proving the reliability of the base isolation system. Since September in 1986, more than thirty earthquakes have been observed. This paper presents the results of the earthquake response observation

  7. Identification of the Response of a Controlled Building Structure Subjected to Seismic Load by Using Nonlinear System Models

    Directory of Open Access Journals (Sweden)

    Mosbeh R. Kaloop

    2016-10-01

    Full Text Available The present study investigates the prediction efficiency of nonlinear system-identification models, in assessing the behavior of a coupled structure-passive vibration controller. Two system-identification models, including Nonlinear AutoRegresive with eXogenous inputs (NARX and adaptive neuro-fuzzy inference system (ANFIS, are used to model the behavior of an experimentally scaled three-story building incorporated with a tuned mass damper (TMD subjected to seismic loads. The experimental study is performed to generate the input and output data sets for training and testing the designed models. The parameters of root-mean-squared error, mean absolute error and determination coefficient statistics are used to compare the performance of the aforementioned models. A TMD controller system works efficiently to mitigate the structural vibration. The results revealed that the NARX and ANFIS models could be used to identify the response of a controlled structure. The parameters of both two time-delays of the structure response and the seismic load were proven to be effective tools in identifying the performance of the models. A comparison based on the parametric evaluation of the two methods showed that the NARX model outperforms the ANFIS model in identifying structures response.

  8. Seismic response analysis of nuclear reactor buildings under consideration of soil-structure interaction with torsional behavior

    International Nuclear Information System (INIS)

    Mizuno, N.; Iida, T.; Tsushima, Y.; Araki, T.; Nojima, O.

    1977-01-01

    In this paper, the seismic response analysis is described in detail for estimating the soil-structure interaction effects with the torsional behavior. The analytical method is firstly shown for estimating the stiffness of reactor building by the bending-shear and torsion theory of the thin wall sections in regard to the behavior of structure. The three-dimensional behavior of structure can be obtained more briefly and simply by the proposed method. Secondly, the dynamical soil-foundation coefficient for estimating the dissipation of vibrational energy on the ground is derived by H. Tajimi's theory which is based on a solution of the propagation of seismic waves caused by point excitation on the surface of the elastic half-space medium. The above results give the vibrational impedances of the soil-foundation corresponding to the static soil coefficient, which is defined to the excitation force in the frequency domain. In order to analyze to the equivalues of reactor building, the authors thirdly attempt to approximate the dynamic soil-foundation coefficient as the frequency transfer function of displacement. The complex damping is used for more suitably estimating the elastic structural damping effects of structure. The regression analysis of many degrees of freedom is fourthly attempted for estimating the natural periods annd equivalent viscous damping ratios directly from the experimental results by the forced vibrational test performed in 1974. The analytical results are finally shown for simulating and comparing with the above-mentioned experimental results

  9. Effects of non-uniform embedments on earthquake responses of nuclear reactor building

    International Nuclear Information System (INIS)

    Koyanagi, Y.; Okamoto, S.; Yoshida, K.; Inove, H.

    1989-01-01

    The nuclear reactor buildings have the portion embedded in soil. In the seismic design of such structures, it is essential to consider the effects of the embedment on the earthquake response. Most studies on these effects, however, assume the uniform embedment, i.e. the depth of the embedment is constant, which is convenient for the design and analysis. The behavior of the earthquake response considering the three-dimensional aspects of non-uniform embedment has not been made clear yet. In this paper, the authors evaluate the effects of the non-uniform embedment in an inclined ground surface on the earthquake response of a nuclear reactor building as illustrated. A typical PWR type reactor building is chosen as an analysis structure model. Four different types of embedment are set up for the comparison study. The three-dimensional analysis is carried out considering the geometry of embedment

  10. The structural response and manner of progressive collapse in RC buildings under the blast and Provide approaches to retrofitting columns against blast

    Directory of Open Access Journals (Sweden)

    GholamReza Havaei

    2017-05-01

    Full Text Available In accidents caused by explosion, the initial damage is usually caused by direct hit blast that it causes damage and serious destruction of structural components. In this state, the collapse of structural components and the subsequent progressive collapse may cause an increase in damages and eventually collapse of the structure. On the other hand, observations show that most of these buildings designed and built without consideration of their vulnerability to such events. In this study, global and local response of reinforced concrete buildings and their damages evaluated against explosion. First the global stability of building using SAP2000 is evaluated against explosion and then the amount and behaviour of damages in The key structural components of the building after the explosion is investigated using LS DYNA. The study involved four important areas in structural engineering that includes blast load determination, numerical modelling with FEM techniques, material performance under high strain rate and non-linear dynamic analysis. Two types of design methods are recommended for RC columns to provide superior residual capacities. They are RC columns detailing with additional steel reinforcement cages and a composite columns including a central structural steel core. The results showed that the use of this type of columns compared to typical RC column against explosion can have a significant impact in increasing the bearing capacity of structural components against gravity loads after the explosion.

  11. Smart Buildings and Demand Response

    Science.gov (United States)

    Kiliccote, Sila; Piette, Mary Ann; Ghatikar, Girish

    2011-11-01

    Advances in communications and control technology, the strengthening of the Internet, and the growing appreciation of the urgency to reduce demand side energy use are motivating the development of improvements in both energy efficiency and demand response (DR) systems in buildings. This paper provides a framework linking continuous energy management and continuous communications for automated demand response (Auto-DR) in various times scales. We provide a set of concepts for monitoring and controls linked to standards and procedures such as Open Automation Demand Response Communication Standards (OpenADR). Basic building energy science and control issues in this approach begin with key building components, systems, end-uses and whole building energy performance metrics. The paper presents a framework about when energy is used, levels of services by energy using systems, granularity of control, and speed of telemetry. DR, when defined as a discrete event, requires a different set of building service levels than daily operations. We provide examples of lessons from DR case studies and links to energy efficiency.

  12. Application of Time Domain PARET to the measured responses of a building

    International Nuclear Information System (INIS)

    Lager, D.L.

    1979-01-01

    The application of the Time Domain PARET (TDP) algorithm to data obtained from the measured responses of a three story reinforced concrete building approximately 465 feet long by 220 feet wide by 40 feet high, with 12 to 18 inch thick walls, is described. The measurements were taken by Agbabian Associates, El Segundo, California. The structure was excited by a device developed at Agbabian that uses a mass sliding down a rod to cut metal disks attached to the rod. The result is a series of impulse forces driving the building at the attachment point of the rod. The responses measured were the accelerations at two locations on the structure. A constraint imposed was that the equipment in the building must remain operating during the time the measurements were made

  13. Dynamic analysis of clustered building structures using substructures methods

    International Nuclear Information System (INIS)

    Leimbach, K.R.; Krutzik, N.J.

    1989-01-01

    The dynamic substructure approach to the building cluster on a common base mat starts with the generation of Ritz-vectors for each building on a rigid foundation. The base mat plus the foundation soil is subjected to kinematic constraint modes, for example constant, linear, quadratic or cubic constraints. These constraint modes are also imposed on the buildings. By enforcing kinematic compatibility of the complete structural system on the basis of the constraint modes a reduced Ritz model of the complete cluster is obtained. This reduced model can now be analyzed by modal time history or response spectrum methods

  14. Seismic response analyses of turbine hall and electrical building of RBMK-1000 MW type NPP

    International Nuclear Information System (INIS)

    Jordanov, M.J.; Karparov, K.T.

    2003-01-01

    This paper addresses results obtained during the study of turbine hall and electrical building of RBMK-1000 MW pair units at Leningradskaya NPP (LNPP) for seismic event. The study was performed in the frame of the Coordinated Research Program of the International Atomic Agency (IAEA) on Safety of RBMK type Nuclear Power Plants (NPP) in Relation of External Events. A 3-D finite element model of Main Building Complex was developed and seismic response analyses were performed taking into account the soil-structure interaction (SSI). The standard mode superposition method was used for evaluation of dynamic response of structure in time domain. The structure was assumed surface founded at the basemat level. Seismic response analyses were carried out considering shear wave propagation pattern for the input motion. The in-structure time histories and response spectra were generated in referenced locations. Conclusions are drawn for the reliability of the structural response evaluation considering the soil-structure interaction effects. (author)

  15. ORGANIZATIONAL STRUCTURE FOR BUILDINGS RECONSTRUCTION OF HISTORICAL BUILDING OF ODESSA

    Directory of Open Access Journals (Sweden)

    POSTERNAK I. М.

    2016-12-01

    Full Text Available Formulation of the problem. As one of perspective forms of integration various complexes act in town-planning structure. In the course of formation of plans of social and economic development of large cities even more often there is a situation when for increase of efficiency of used resources concentration of efforts is necessary not simply, but also new progressive forms of the organization of building manufacture. Purpose. To offer the organizational structure using in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa 1820 … 1920 years under standards power efficiency and to execute researches engineering architectonics residential buildings of historical building of a city of Odessa. Conclusion. It is offered to create in the city of Odessa "the Corporate scientific and technical complex town-planning power reconstruction "CSTC T-PPR", as innovative organizational structure which uses in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa under standards power efficiency. It is considered engineering architectonics residential buildings of historical building of a city of Odessa, in particular, not looking on diverse buildings of inhabited appointment of Odessa, for them there are defining factors on which probably to make their grouping and at the same time to allocate the general lines inherent to a housing estate as a whole. It is resulted a general characteristic and classification of residential buildings of historical building of a city of Odessa ХІХ … beginnings ХХ centuries It is allocated and expanded classification of such buildings of inhabited appointment by duration of residing at them.

  16. ORGANIZATIONAL STRUCTURE FOR RECONSTRUCTION OF BUILDINGS HISTORICAL BUILDING OF ODESSA

    Directory of Open Access Journals (Sweden)

    POSTERNAK I. М.

    2017-05-01

    Full Text Available Summary. Raising of problem. As one of perspective forms of integration various complexes act in town- planning structure. In the course of formation of plans of social and economic development of large cities even more often there is a situation when for increase of efficiency of used resources concentration of efforts is necessary not simply, but also new progressive forms of the organization of building manufacture. Purpose. To offer the organizational structure using in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa 1820 … 1920 years under standards power efficiency and to execute researches engineering architectonics residential buildings of historical building of a city of Odessa. Conclusion. It is offered to create in the city of Odessa "the Corporate scientific and technical complex town-planning power reconstruction "CSTC T-PPR", as innovative organizational structure which uses in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa under standards power efficiency. It is considered engineering architectonics residential buildings of historical building of a city of Odessa, in particular, not looking on diverse buildings of inhabited appointment of Odessa, for them there are defining factors on which probably to make their grouping and at the same time to allocate the general lines inherent to a housing estate as a whole. It is resulted a general characteristic and classification of residential buildings of historical building of a city of Odessa ХІХ beginnings ХХ centuries It is allocated and expanded classification of such buildings of inhabited appointment by duration of residing at them.

  17. Measurement and evaluation of high-rise building response to ground motion generated by underground nuclear explosions

    International Nuclear Information System (INIS)

    Honda, K.K.

    1976-01-01

    As part of the structural response research program being conducted for ERDA, the response behavior of high-rise buildings in Las Vegas, Nevada, due to ground motion caused by underground nuclear explosions (UNEs) at the Nevada Test Site (NTS) has been measured for the past 12 years. Results obtained include variation in dynamic response properties as a function of amplitude of motion, influence of nonstructural partitions in the building response, and comparison of calculated and measured response. These data for three reinforced concrete high-rise buildings, all designed as moment-resisting space frames are presented

  18. Seismic response and damage detection analyses of an instrumented steel moment-framed building

    Science.gov (United States)

    Rodgers, J.E.; Celebi, M.

    2006-01-01

    The seismic performance of steel moment-framed buildings has been of particular interest since brittle fractures were discovered at the beam-column connections in a number of buildings following the M 6.7 Northridge earthquake of January 17, 1994. A case study of the seismic behavior of an extensively instrumented 13-story steel moment frame building located in the greater Los Angeles area of California is described herein. Response studies using frequency domain, joint time-frequency, system identification, and simple damage detection analyses are performed using an extensive strong motion dataset dating from 1971 to the present, supported by engineering drawings and results of postearthquake inspections. These studies show that the building's response is more complex than would be expected from its highly symmetrical geometry. The response is characterized by low damping in the fundamental mode, larger accelerations in the middle and lower stories than at the roof and base, extended periods of vibration after the cessation of strong input shaking, beating in the response, elliptical particle motion, and significant torsion during strong shaking at the top of the concrete piers which extend from the basement to the second floor. The analyses conducted indicate that the response of the structure was elastic in all recorded earthquakes to date, including Northridge. Also, several simple damage detection methods employed did not indicate any structural damage or connection fractures. The combination of a large, real structure and low instrumentation density precluded the application of many recently proposed advanced damage detection methods in this case study. Overall, however, the findings of this study are consistent with the limited code-compliant postearthquake intrusive inspections conducted after the Northridge earthquake, which found no connection fractures or other structural damage. ?? ASCE.

  19. Structural integrity analysis of an INPP building under external loading

    International Nuclear Information System (INIS)

    Dundulis, G.; Karalevicius, R.; Uspuras, E.; Kulak, R.F.; Marchertas, A.

    2005-01-01

    After the terrorist attacks in New York and Washington D. C. using civil airplanes, the evaluation of civil airplane crashes into civil and NPP structures has become very important. The interceptions of many terrorists' communications reveal that the use of commandeered commercial aircraft is still a major part of their plans for destruction. Aircraft crash or other flying objects in the territory of the Ignalina Nuclear Power Plant (INPP) represents a concern to the plant. Aircraft traveling at high velocity have a destructive potential. The aircraft crash may damage the roof and walls of buildings, pipelines, electric motors, cases of power supplies, power cables of electricity transmission and other elements and systems, which are important for safety. Therefore, the evaluation of the structural response to an of aircraft crash is important and was selected for analysis. The structural integrity analysis due to the effects of an aircraft crash on an NPP building structure is the subject of this paper. The finite element method was used for the structural analysis of a typical Ignalina NPP building. The structural integrity analysis was performed for a portion of the ALS using the dynamic loading of an aircraft crash impact model. The computer code NEPTUNE was used for this analysis. The local effects caused by impact of the aircraft's engine on the building wall were evaluated independently by using an empirical formula. (authors)

  20. 7 CFR 51.56 - Buildings and structures.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Buildings and structures. 51.56 Section 51.56... § 51.56 Buildings and structures. The packing plant buildings shall be properly constructed and... be sufficient light consistent with the use to which the particular portion of the building is...

  1. Seismic Safety Program: Ground motion and structural response

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    In 1964, John A. Blume & Associates Research Division (Blume) began a broad-range structural response program to assist the Nevada Operations Office of the US Atomic Energy Commission (AEC) in ensuring the continued safe conduct of underground nuclear detonation testing at the Nevada Test Site (NTS) and elsewhere. Blume`s long experience in earthquake engineering provided a general basis for the program, but much more specialized knowledge was required for the AEC`s purposes. Over the next 24 years Blume conducted a major research program to provide essential understanding of the detailed nature of the response of structures to dynamic loads such as those imposed by seismic wave propagation. The program`s results have been embodied in a prediction technology which has served to provide reliable advanced knowledge of the probable effects of seismic ground motion on all kinds of structures, for use in earthquake engineering and in building codes as well as for the continuing needs of the US Department of Energy`s Nevada Operations Office (DOE/NV). This report is primarily an accounting of the Blume work, beginning with the setting in 1964 and the perception of the program needs as envisioned by Dr. John A. Blume. Subsequent chapters describe the structural response program in detail and the structural prediction procedures which resulted; the intensive data acquisition program which, as is discussed at some length, relied heavily on the contributions of other consultant-contractors in the DOE/NV Seismic Safety Support Program; laboratory and field studies to provide data on building elements and structures subjected to dynamic loads from sources ranging from testing machines to earthquakes; structural response activities undertaken for testing at the NTS and for off-NTS underground nuclear detonations; and concluding with an account of corollary studies including effects of natural forces and of related studies on building response.

  2. Determining building interior structures using compressive sensing

    Science.gov (United States)

    Lagunas, Eva; Amin, Moeness G.; Ahmad, Fauzia; Nájar, Montse

    2013-04-01

    We consider imaging of the building interior structures using compressive sensing (CS) with applications to through-the-wall imaging and urban sensing. We consider a monostatic synthetic aperture radar imaging system employing stepped frequency waveform. The proposed approach exploits prior information of building construction practices to form an appropriate sparse representation of the building interior layout. We devise a dictionary of possible wall locations, which is consistent with the fact that interior walls are typically parallel or perpendicular to the front wall. The dictionary accounts for the dominant normal angle reflections from exterior and interior walls for the monostatic imaging system. CS is applied to a reduced set of observations to recover the true positions of the walls. Additional information about interior walls can be obtained using a dictionary of possible corner reflectors, which is the response of the junction of two walls. Supporting results based on simulation and laboratory experiments are provided. It is shown that the proposed sparsifying basis outperforms the conventional through-the-wall CS model, the wavelet sparsifying basis, and the block sparse model for building interior layout detection.

  3. Structural safety of HDR reactor building during large scale vibration tests

    International Nuclear Information System (INIS)

    Stangenberg, F.; Zinn, R.

    1985-01-01

    In the second phase of the HDR investigations, a high shaker excitation of the building is planned using a large shaker which will be located on the operating floor and will be brought up to speed in a balanced condition and then unbalanced and decoupled from the drive system. With decreasing speed the shaker comes in resonance with the building frequencies and its energy is transferred to the building. In this paper the structural safety of the reactor building during the projected shaker tests is analysed. Dynamic response calculations with coupling between building and shaker by simultaneously integrating the equilibrium equations of both building and shaker are presented. The resulting building stresses, soil pressures etc. are compared with allowable values. (orig.)

  4. Pressure integration technique for predicting wind-induced response in high-rise buildings

    Directory of Open Access Journals (Sweden)

    Aly Mousaad Aly

    2013-12-01

    Full Text Available This paper presents a procedure for response prediction in high-rise buildings under wind loads. The procedure is illustrated in an application example of a tall building exposed to both cross-wind and along-wind loads. The responses of the building in the lateral directions combined with torsion are estimated simultaneously. Results show good agreement with recent design standards; however, the proposed procedure has the advantages of accounting for complex mode shapes, non-uniform mass distribution, and interference effects from the surrounding. In addition, the technique allows for the contribution of higher modes. For accurate estimation of the acceleration response, it is important to consider not only the first two lateral vibrational modes, but also higher modes. Ignoring the contribution of higher modes may lead to underestimation of the acceleration response; on the other hand, it could result in overestimation of the displacement response. Furthermore, the procedure presented in this study can help decision makers, involved in a tall building design/retrofit to choose among innovative solutions like aerodynamic mitigation, structural member size adjustment, damping enhancement, and/or materials change, with an objective to improve the resiliency and the serviceability under extreme wind actions.

  5. Soil-structure interaction in fuel handling building

    International Nuclear Information System (INIS)

    Elaidi, B.M.; Eissa, M.A.

    1998-01-01

    This paper presents an accurate three-dimensional seismic soil-structure interaction analysis for large structures. The method is applied to the fuel building in nuclear power plants. The analysis is performed numerically in the frequency domain and the responses are obtained by inverse Fourier transformation. The size of the structure matrices is reduced by transforming the equation of motion to the modal coordinate system. The soil is simulated as a layered media on top of viscoelastic half space. Soil impedance matrices are calculated from the principles of continuum mechanics and account for soil stiffness and energy dissipation. Effects of embedment on the field equations is incorporated through the scattering matrices or by simply scaling the soil impedance. Finite element methods are used to discretize the concrete foundation for the generation of the soil interaction matrices. Decoupling of the sloshing water in the spent fuel pools and the free-standing spent fuel racks is simulated. The input seismic motions are defined by three artificial time history accelerations. These input motions are generated to match the ground design basis response spectra and the target power spectral density function. The methods described in this paper can handle arbitrary foundation layouts, allows for large structural models, and accurately represents the soil impedance. Time history acceleration responses were subsequently used to generate floor response spectra at applicable damping values. (orig.)

  6. Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Design, Construction, and Assessment

    Directory of Open Access Journals (Sweden)

    Massimiliano Ferraioli

    2017-01-01

    Full Text Available The paper deals with the seismic retrofit of a multiple building structure belonging to the Hospital Centre of Avellino (Italy. At first, the paper presents the preliminary investigations, the in situ measurements and laboratory tests, and the seismic assessment of the existing fixed-base structures. Having studied different strategies, base isolation proved to be the more appropriate, also for the possibility offered by the geometry of the building to easily create an isolation interface at the ground level. The paper presents the design project, the construction process, and the details of the isolation intervention. Some specific issues of base isolation for seismic retrofitting of multiple building structures were lightened. Finally, the seismic assessment of the base-isolated building was carried out. The seismic response was evaluated through nonlinear time-history analysis, using the well-known Bouc-Wen model as the constitutive law of the isolation bearings. For reliable dynamic analyses, a suite of natural accelerograms compatible with acceleration spectra of Italian Code was first selected and then applied along both horizontal directions. The results were finally used to address some of the critical issues of the seismic response of the base-isolated multiple building structure: accidental torsional effects and potential poundings during strong earthquakes.

  7. Field Measurement-Based System Identification and Dynamic Response Prediction of a Unique MIT Building.

    Science.gov (United States)

    Cha, Young-Jin; Trocha, Peter; Büyüköztürk, Oral

    2016-07-01

    Tall buildings are ubiquitous in major cities and house the homes and workplaces of many individuals. However, relatively few studies have been carried out to study the dynamic characteristics of tall buildings based on field measurements. In this paper, the dynamic behavior of the Green Building, a unique 21-story tall structure located on the campus of the Massachusetts Institute of Technology (MIT, Cambridge, MA, USA), was characterized and modeled as a simplified lumped-mass beam model (SLMM), using data from a network of accelerometers. The accelerometer network was used to record structural responses due to ambient vibrations, blast loading, and the October 16th 2012 earthquake near Hollis Center (ME, USA). Spectral and signal coherence analysis of the collected data was used to identify natural frequencies, modes, foundation rocking behavior, and structural asymmetries. A relation between foundation rocking and structural natural frequencies was also found. Natural frequencies and structural acceleration from the field measurements were compared with those predicted by the SLMM which was updated by inverse solving based on advanced multiobjective optimization methods using the measured structural responses and found to have good agreement.

  8. Field Measurement-Based System Identification and Dynamic Response Prediction of a Unique MIT Building

    Directory of Open Access Journals (Sweden)

    Young-Jin Cha

    2016-07-01

    Full Text Available Tall buildings are ubiquitous in major cities and house the homes and workplaces of many individuals. However, relatively few studies have been carried out to study the dynamic characteristics of tall buildings based on field measurements. In this paper, the dynamic behavior of the Green Building, a unique 21-story tall structure located on the campus of the Massachusetts Institute of Technology (MIT, Cambridge, MA, USA, was characterized and modeled as a simplified lumped-mass beam model (SLMM, using data from a network of accelerometers. The accelerometer network was used to record structural responses due to ambient vibrations, blast loading, and the October 16th 2012 earthquake near Hollis Center (ME, USA. Spectral and signal coherence analysis of the collected data was used to identify natural frequencies, modes, foundation rocking behavior, and structural asymmetries. A relation between foundation rocking and structural natural frequencies was also found. Natural frequencies and structural acceleration from the field measurements were compared with those predicted by the SLMM which was updated by inverse solving based on advanced multiobjective optimization methods using the measured structural responses and found to have good agreement.

  9. Field Measurement-Based System Identification and Dynamic Response Prediction of a Unique MIT Building

    Science.gov (United States)

    Cha, Young-Jin; Trocha, Peter; Büyüköztürk, Oral

    2016-01-01

    Tall buildings are ubiquitous in major cities and house the homes and workplaces of many individuals. However, relatively few studies have been carried out to study the dynamic characteristics of tall buildings based on field measurements. In this paper, the dynamic behavior of the Green Building, a unique 21-story tall structure located on the campus of the Massachusetts Institute of Technology (MIT, Cambridge, MA, USA), was characterized and modeled as a simplified lumped-mass beam model (SLMM), using data from a network of accelerometers. The accelerometer network was used to record structural responses due to ambient vibrations, blast loading, and the October 16th 2012 earthquake near Hollis Center (ME, USA). Spectral and signal coherence analysis of the collected data was used to identify natural frequencies, modes, foundation rocking behavior, and structural asymmetries. A relation between foundation rocking and structural natural frequencies was also found. Natural frequencies and structural acceleration from the field measurements were compared with those predicted by the SLMM which was updated by inverse solving based on advanced multiobjective optimization methods using the measured structural responses and found to have good agreement. PMID:27376303

  10. Response of the main building, unit 5, Kozloduy NPP (Bulgaria) to an explosion input motion

    International Nuclear Information System (INIS)

    Kostov, M.; Boncheva, H.; Varbanov, G.; Kaneva, A.; Stefanov, D.; Koleva, N.

    1999-01-01

    The main building of Unit 5, NPP Kozloduy is one of the two selected prototypes of WWER-type plants included in the project 'Benchmark study for seismic analysis and testing of WWER-type nuclear power plants', co-ordinated by IAEA. The dynamic in-situ testing of the structure of Unit 5 WWER-1000 MW reactor containment building and the adjacent auxiliary structures is performed by specialists of ISMES (Italy), assisted by Hungarian consultants (GEOPARD) and Bulgarian specialist of NPP Kozloduy. The aim of the experiment is to assess the dynamic characteristics and behaviour of the structures, the soil-structure interaction effects, the equipment-structure interaction, etc. The dynamic excitation is a low level ground motion induced by underground explosions. The measuring of the response is done at different pre-selected structure points. Two experiments are performed. The registrations during the second experiment of 01.07.1996 are used in the present report. One set of free field records are given up to the participant institutions for the benchmarking. The purpose is to perform a dynamic analysis of the main building of Unit 5, to assess the response to the explosion ground motion and to compare the analytical results with the recorded motion. In this report are discussed soil and structure modelling and computation results consisting in acceleration response spectra obtained at foundation level and at different points of the structure

  11. Dynamic Analysis of AP1000 Shield Building Considering Fluid and Structure Interaction Effects

    Directory of Open Access Journals (Sweden)

    Qiang Xu

    2016-02-01

    Full Text Available The shield building of AP1000 was designed to protect the steel containment vessel of the nuclear reactor. Therefore, the safety and integrity must be ensured during the plant life in any conditions such as an earthquake. The aim of this paper is to study the effect of water in the water tank on the response of the AP1000 shield building when subjected to three-dimensional seismic ground acceleration. The smoothed particle hydrodynamics method (SPH and finite element method (FEM coupling method is used to numerically simulate the fluid and structure interaction (FSI between water in the water tank and the AP1000 shield building. Then the grid convergence of FEM and SPH for the AP1000 shield building is analyzed. Next the modal analysis of the AP1000 shield building with various water levels (WLs in the water tank is taken. Meanwhile, the pressure due to sloshing and oscillation of the water in the gravity drain water tank is studied. The influences of the height of water in the water tank on the time history of acceleration of the AP1000 shield building are discussed, as well as the distributions of amplification, acceleration, displacement, and stresses of the AP1000 shield building. Research on the relationship between the WLs in the water tank and the response spectrums of the structure are also taken. The results show that the high WL in the water tank can limit the vibration of the AP1000 shield building and can more efficiently dissipate the kinetic energy of the AP1000 shield building by fluid-structure interaction.

  12. Effect of foundation embedment on the response of a multi-story building to earthquake excitation

    Directory of Open Access Journals (Sweden)

    Hamood Mohammed

    2018-01-01

    Full Text Available During an earthquake, the behaviour of any structure is affected not only by the superstructure response, but also by the response of the soil beneath. Recent structural failure patterns have indicated the significance of soil-structure interaction (SSI effects. The present study focuses on SSI analysis considering the embedment depth of the foundation of a symmetric six stories reinforced concrete (RCspace bare frame building resting on stiff soil and subjected to seismic loading. The finite element analysis software ANSYS v17.2 is used. Time history (TH analysis has been adopted. The Response in terms of lateral displacements, base shear forces, base moments and variation in natural time periods are calculated from the analysis of the soil foundation structure interaction (SFSI model. Results are compared with that obtained from conventional method assuming rigid support at the base (fixed base of the structure. The results show that the SFSI considering different embedment depths are significant in altering the seismic response of the multi-story building (MSB.

  13. Strategies for Demand Response in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Watson, David S.; Kiliccote, Sila; Motegi, Naoya; Piette, Mary Ann

    2006-06-20

    This paper describes strategies that can be used in commercial buildings to temporarily reduce electric load in response to electric grid emergencies in which supplies are limited or in response to high prices that would be incurred if these strategies were not employed. The demand response strategies discussed herein are based on the results of three years of automated demand response field tests in which 28 commercial facilities with an occupied area totaling over 11 million ft{sup 2} were tested. Although the demand response events in the field tests were initiated remotely and performed automatically, the strategies used could also be initiated by on-site building operators and performed manually, if desired. While energy efficiency measures can be used during normal building operations, demand response measures are transient; they are employed to produce a temporary reduction in demand. Demand response strategies achieve reductions in electric demand by temporarily reducing the level of service in facilities. Heating ventilating and air conditioning (HVAC) and lighting are the systems most commonly adjusted for demand response in commercial buildings. The goal of demand response strategies is to meet the electric shed savings targets while minimizing any negative impacts on the occupants of the buildings or the processes that they perform. Occupant complaints were minimal in the field tests. In some cases, ''reductions'' in service level actually improved occupant comfort or productivity. In other cases, permanent improvements in efficiency were discovered through the planning and implementation of ''temporary'' demand response strategies. The DR strategies that are available to a given facility are based on factors such as the type of HVAC, lighting and energy management and control systems (EMCS) installed at the site.

  14. Damping in building structures during earthquakes: test data and modeling

    International Nuclear Information System (INIS)

    Coats, D.W. Jr.

    1982-01-01

    A review and evaluation of the state-of-the-art of damping in building structures during earthquakes is presented. The primary emphasis is in the following areas: 1) the evaluation of commonly used mathematical techniques for incorporating damping effects in both simple and complex systems; 2) a compilation and interpretation of damping test data; and 3) an evaluation of structure testing methods, building instrumentation practices, and an investigation of rigid-body rotation effects on damping values from test data. A literature review provided the basis for evaluating mathematical techiques used to incorporate earthquake induced damping effects in simple and complex systems. A discussion on the effectiveness of damping, as a function of excitation type, is also included. Test data, from a wide range of sources, has been compiled and interpreted for buidings, nuclear power plant structures, piping, equipment, and isolated structural elements. Test methods used to determine damping and frequency parameters are discussed. In particular, the advantages and disadvantages associated with the normal mode and transfer function approaches are evaluated. Additionally, the effect of rigid-body rotations on damping values deduced from strong-motion building response records is investigated. A discussion of identification techniques typically used to determine building parameters (frequency and damping) from strong motion records is included. Finally, an analytical demonstration problem is presented to quantify the potential error in predicting fixed-base structural frequency and damping values from strong motion records, when rigid-body rotations are not properly accounted for

  15. Super-structure and building performance

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2010-11-01

    Full Text Available The super-structure consists predominantly of the load- and no-load-bearing walls-including all doors and windows and suspended floor slabs. The building envelope plays a significant role in the performance of a building, especially with regard...

  16. On the response of a reactor building and its equipment to aircraft crash

    International Nuclear Information System (INIS)

    Larsson, G.; Lundsager, P.

    1977-01-01

    The present study investigates the dynamic response of the ASEA-ATOM BWR 75 reactor building in terms of response spectra at significant locations considering various aircraft and points of load application. In the first part of the study a total of 21 forcing functions, most of them from the open literature and including the commonly used standard functions, have been studied with respect to documentation, consistency and frequency content. Since none of the forcing functions have been experimentally verified, their validity must be assessed mainly by judging the structural models and assumptions used in their derivation and by checking their consistency. In the second part, linear dynamical models of various degrees of detailedness have been investigated regarding their capacity to describe the behavior of the reactor building under this high frequency loading. The most detailed model consists of plane stress finite elements for every significant wall and floor. In the third part of the study the effects of a number of parameters on the response of the building are investigated. The parameters include the points of attack, damping values, soil spring stiffness as well as different forcing functions of various frequency contents. The reponse is displayed as response spectra and member forces for characteristic locations. The results serve as a basis for development of standardized design floor response spectra and for the structural verification of the bui

  17. Structural building screening and evaluation

    Science.gov (United States)

    Kurniawandy, Alex; Nakazawa, Shoji; Hendry, Andy; Ridwan, Firdaus, Rahmatul

    2017-10-01

    An earthquake is a disaster that can be harmful to the community, such as financial loss and also dead injuries. Pekanbaru is a city that located in the middle of Sumatera Island. Even though the city of Pekanbaru is a city that rarely occurs earthquake, but Pekanbaru has ever felt the impact of the big earthquake that occurred in West Sumatera on September 2009. As we know, Indonesia located between Eurasia plate, Pacific plate, and Indo-Australian plate. Particularly the Sumatera Island, It has the Semangko fault or the great Sumatra fault along the island from north to south due to the shift of Eurasia and Indo-Australian Plates. An earthquake is not killing people but the building around the people that could be killing them. The failure of the building can be early prevented by doing an evaluation. In this research, the methods of evaluation have used a guideline for the Federal Emergency Management Agency (FEMA) P-154 and Applied Technology Council (ATC) 40. FEMA P-154 is a rapid visual screening of buildings for potential seismic hazards and ATC-40 is seismic evaluation and retrofit of Concrete Buildings. ATC-40 is a more complex evaluation rather than FEMA P-154. The samples to be evaluated are taken in the surroundings of Universitas Riau facility in Pekanbaru. There are four buildings as case study such as the rent student building, the building of mathematics and natural science faculty, the building teacher training and education faculty and the buildings in the faculty of Social political sciences. Vulnerability for every building facing an earthquake is different, this is depending on structural and non-structural components of the building. Among all of the samples, only the building of mathematics and the natural science faculty is in critical condition according to the FEMA P-154 evaluation. Furthermore, the results of evaluation using ATC-40 for the teacher training building are in damage control conditions, despite the other three buildings are

  18. LQG Control of Along-Wind Response of a Tall Building with an ATMD

    Directory of Open Access Journals (Sweden)

    Ki-Pyo You

    2014-01-01

    Full Text Available Modern tall buildings use lighter construction materials that have high strength and less stiffness and are more flexible. Although this results in the improvement of structural safety, excessive wind-induced excitations could lead to occupant discomfort. The optimal control law of a linear quadratic Gaussian (LQG controller with an active tuned mass damper (ATMD is used for reducing the along-wind response of a tall building. ATMD consists of a second mass with optimum parameters for tuning frequency and damping ratio of the tuned mass damper (TMD, under the stationary random load, was used. A fluctuating along-wind load, acting on a tall building, was treated as a stationary Gaussian white noise and was simulated numerically, in the time domain, using the along-wind load spectra proposed by G. Solari in 1993. Using this simulated wind load, it was possible to calculate the along-wind responses of a tall building (with and without the ATMD, using an LQG controller. Comparing the RMS (root mean square response revealed that the numerically simulated along-wind responses, without ATMD, are a good approximation to the closed form response, and that the reduced responses with ATMD and LQG controller were estimated by varying the values of control design parameters.

  19. Iterative model-building, structure refinement, and density modification with the PHENIX AutoBuild Wizard

    Energy Technology Data Exchange (ETDEWEB)

    Los Alamos National Laboratory, Mailstop M888, Los Alamos, NM 87545, USA; Lawrence Berkeley National Laboratory, One Cyclotron Road, Building 64R0121, Berkeley, CA 94720, USA; Department of Haematology, University of Cambridge, Cambridge CB2 0XY, England; Terwilliger, Thomas; Terwilliger, T.C.; Grosse-Kunstleve, Ralf Wilhelm; Afonine, P.V.; Moriarty, N.W.; Zwart, P.H.; Hung, L.-W.; Read, R.J.; Adams, P.D.

    2007-04-29

    The PHENIX AutoBuild Wizard is a highly automated tool for iterative model-building, structure refinement and density modification using RESOLVE or TEXTAL model-building, RESOLVE statistical density modification, and phenix.refine structure refinement. Recent advances in the AutoBuild Wizard and phenix.refine include automated detection and application of NCS from models as they are built, extensive model completion algorithms, and automated solvent molecule picking. Model completion algorithms in the AutoBuild Wizard include loop-building, crossovers between chains in different models of a structure, and side-chain optimization. The AutoBuild Wizard has been applied to a set of 48 structures at resolutions ranging from 1.1 {angstrom} to 3.2 {angstrom}, resulting in a mean R-factor of 0.24 and a mean free R factor of 0.29. The R-factor of the final model is dependent on the quality of the starting electron density, and relatively independent of resolution.

  20. Elasto-plastic response of multi-story shear wall structures

    International Nuclear Information System (INIS)

    Mizutani, M.; Yamazaki, F.

    1987-01-01

    A Monte Carlo simulation study is carried out. The relationship between the elastoplastic and linear response for multi-DOF systems is developed based on the results of the simulation study. Several 6-story shear wall structures are considered as structural models which represent typical nuclear power plant buildings. A bilinear force-displacement relationship is assumed for each story. A number of artificial earthquakes based on the Kanai-Tajimi power spectrum and trapezoidal envelope function are used as the input ground motion. The least square method is introduced for the purpose of evaluating the median relationship between the ductility factor and linear response from the simulated data and also evaluating the deviation from this median relationship. This relationship derived for the 6-story buildings is compared with the currently used energy absorption factor and the simulation results for Zion auxiliary building model. (orig./HP)

  1. Iterative model building, structure refinement and density modification with the PHENIX AutoBuild wizard

    International Nuclear Information System (INIS)

    Terwilliger, Thomas C.; Grosse-Kunstleve, Ralf W.; Afonine, Pavel V.; Moriarty, Nigel W.; Zwart, Peter H.; Hung, Li-Wei; Read, Randy J.; Adams, Paul D.

    2008-01-01

    The highly automated PHENIX AutoBuild wizard is described. The procedure can be applied equally well to phases derived from isomorphous/anomalous and molecular-replacement methods. The PHENIX AutoBuild wizard is a highly automated tool for iterative model building, structure refinement and density modification using RESOLVE model building, RESOLVE statistical density modification and phenix.refine structure refinement. Recent advances in the AutoBuild wizard and phenix.refine include automated detection and application of NCS from models as they are built, extensive model-completion algorithms and automated solvent-molecule picking. Model-completion algorithms in the AutoBuild wizard include loop building, crossovers between chains in different models of a structure and side-chain optimization. The AutoBuild wizard has been applied to a set of 48 structures at resolutions ranging from 1.1 to 3.2 Å, resulting in a mean R factor of 0.24 and a mean free R factor of 0.29. The R factor of the final model is dependent on the quality of the starting electron density and is relatively independent of resolution

  2. STRUCTURAL VULNERABILITY ASSESSMENT OF MASONRY BUILDINGS IN TURKEY

    OpenAIRE

    KORKMAZ, Kasım Armagan; CARHOGLU, Asuman Isıl

    2011-01-01

    Turkey is located in an active seismic zone. Mid to high rise R/C building and low rise masonry buildings are very common construction type in Turkey. In recent earthquakes, lots of existing buildings got damage including masonry buildings. Masonry building history in Turkey goes long years back. For sure, it is an important structure type for Turkey. Therefore, earthquake behavior and structural vulnerability of masonry buildings are crucial issues for Turkey as a earthquake prone country. I...

  3. BIM-Based Timber Structures Refurbishment of the Immovable Heritage Listed Buildings

    Science.gov (United States)

    Henek, Vladan; Venkrbec, Václav

    2017-12-01

    The use of Building information model (BIM) design tools is no longer an exception, but a common issue. When designing new buildings or complex renovations using BIM, the benefits have already been repeatedly published. The essence of BIM is to create a multidimensional geometric model of a planned building electronically on a computer, supplemented with the necessary information in advance of the construction process. Refurbishment is a specific process that combines both - new structures and demolished structures, or structures that need to be dismantled, repaired, and then returned to the original position. Often it can be historically valuable part of the building. BIM-based repairs and refurbishments of the constructions, especially complicated repairs of the structures of roof trusses of immovable heritage listed buildings, have not yet been credibly presented. However, the use of BIM tools may be advantageous in this area, because user can quickly response to the necessary changes that may be needed during refurbishments, but also in connection with the quick assessment and cost estimation of any unexpected additional works. The paper deals with the use of BIM in the field of repairs and refurbishment of the buildings in general. The emphasis on monumentally protected elements was priority. Advantage of the proposal research is demonstrated on case study of the refurbishment of the immovable heritage listed truss roof. According to this study, this construction was realized in the Czech Republic. Case study consists of 3D modelled truss parts and the connected technological workflow base. The project work was carried out in one common model environment.

  4. Predicting Dynamic Response of Structures under Earthquake Loads Using Logical Analysis of Data

    Directory of Open Access Journals (Sweden)

    Ayman Abd-Elhamed

    2018-04-01

    Full Text Available In this paper, logical analysis of data (LAD is used to predict the seismic response of building structures employing the captured dynamic responses. In order to prepare the data, computational simulations using a single degree of freedom (SDOF building model under different ground motion records are carried out. The selected excitation records are real and of different peak ground accelerations (PGA. The sensitivity of the seismic response in terms of displacements of floors to the variation in earthquake characteristics, such as soil class, characteristic period, and time step of records, peak ground displacement, and peak ground velocity, have also been considered. The dynamic equation of motion describing the building model and the applied earthquake load are presented and solved incrementally using the Runge-Kutta method. LAD then finds the characteristic patterns which lead to forecast the seismic response of building structures. The accuracy of LAD is compared to that of an artificial neural network (ANN, since the latter is the most known machine learning technique. Based on the conducted study, the proposed LAD model has been proven to be an efficient technique to learn, simulate, and blindly predict the dynamic response behaviour of building structures subjected to earthquake loads.

  5. Earthquake risk assessment of building structures

    International Nuclear Information System (INIS)

    Ellingwood, Bruce R.

    2001-01-01

    During the past two decades, probabilistic risk analysis tools have been applied to assess the performance of new and existing building structural systems. Structural design and evaluation of buildings and other facilities with regard to their ability to withstand the effects of earthquakes requires special considerations that are not normally a part of such evaluations for other occupancy, service and environmental loads. This paper reviews some of these special considerations, specifically as they pertain to probability-based codified design and reliability-based condition assessment of existing buildings. Difficulties experienced in implementing probability-based limit states design criteria for earthquake are summarized. Comparisons of predicted and observed building damage highlight the limitations of using current deterministic approaches for post-earthquake building condition assessment. The importance of inherent randomness and modeling uncertainty in forecasting building performance is examined through a building fragility assessment of a steel frame with welded connections that was damaged during the Northridge Earthquake of 1994. The prospects for future improvements in earthquake-resistant design procedures based on a more rational probability-based treatment of uncertainty are examined

  6. Low-Level, Measured Response of Los Alamos National Laboratories TA 16 - Building 411 and TA 8 - Building 23 to Direct Flash Attachment of Lightning

    International Nuclear Information System (INIS)

    Dinallo, Michael A.; Holmes, Parris; Merewether, Kimball O.; Morris, Marvin E.

    1999-01-01

    On September 24, 25, 28, and 29, 1998 and on October 19 and 23, 1998, transfer impedance measurements were made on Los Alamos National Laboratories TA 16 - Building 411 and TA 8-- Building 23 to characterize their interior open-circuit voltage response to a direct lightning flash attachment to the structures. The theory, history, measurement methods and equipment, and specific measured results are detailed. The measured results demonstrate that if the remaining metallic penetrations are bonded, then the rebar of the two structures is sufficiently well connected to form a Faraday cage that reduces the maximum open-circuit voltage inside the structure to a sufficiently low level that the required standoff distance to prevent arcing to explosive assemblies is 6.8 inches for TA 16 - Building 411 and is 11.5 inches for TA 8 - Building 23

  7. Response of a NPP reactor building under seismic action with regard to different soil properties

    International Nuclear Information System (INIS)

    Wagenknecht, E.

    1987-01-01

    The object of this investigation is the response of a reactor building on seismic action with systematic variation of the soil stiffness. A thin-walled orthotropic containment shell on varying heavy and rigid foundations is regarded as calculation model. The soil stiffness is simulated by meand of spring elements for horizontal translation and for rocking motions of the building. By the response spectra method the loads of the containment shell are calculated for a horizontal seismic excitation. The investigation is aimed at determining the influence of differentiated soil stiffnesses on the containment action effects and at recognizing the causes for the occuring effects. The results are thoroughly represented by selected quantities of the building's response, the effects from the soil-structure interaction are discussed and the causes of the effects cleary explained. Apossibility is provided for determining critical soil stiffnesses which cause a siginificat intensification effect. The results of the investigations show that both the soil stiffness and structural configuration of the reactor building particulary in case of the substructure being heavy and rigid, exert a decisive on the loading of the superstructure. (orig.)

  8. Dynamic response of aircraft impact of a reactor building with protective shell on independent foundation

    International Nuclear Information System (INIS)

    Constantopoulos, I.V.; Vardanega, C.; Attalla, I.

    1981-01-01

    Aircraft impact loading can penalize significantly the design of the equipment in a conventional containment building. An alternative scheme was developed in an attempt to reduce the aircraft impact response. A preliminary study was carried out to investigate the feasibility of the alternative scheme. This study was made in such perspective and for the purpose of comparing the response to aircraft impact of a standard reactor building, to that of a reactor building having an independently founded outer shell. In the second scheme, the outer shell is meant to receive the aircraft impact, so that the load will be transmitted to the reactor building internals only by way of the structure-soil-structure system. In both cases, the aircraft impact was postulated to occur on a linear single degree of freedom oscillator which modeled, approximately, the plastification of the impact area. The soil was considered as a half-space with properties corresponding to a medium stiff soil, and modeled by lumped soil springs and dashpots. The reactor internals, inner shell and protective outer shell were modeled with beam elements and concentrated inertias. In modeling the coupled system, soil-structure interaction and structure-to-structure interaction through the soil were represented by a global stiffness matrix corresponding to the three degrees the freedom of each foundation, i.e. horizontal, vertical and rocking. (orig./HP)

  9. Influence of turbulence, orientation, and site configuration on the response of buildings to extreme wind.

    Science.gov (United States)

    Aly, Aly Mousaad

    2014-01-01

    Atmospheric turbulence results from the vertical movement of air, together with flow disturbances around surface obstacles which make low- and moderate-level winds extremely irregular. Recent advancements in wind engineering have led to the construction of new facilities for testing residential homes at relatively high Reynolds numbers. However, the generation of a fully developed turbulence in these facilities is challenging. The author proposed techniques for the testing of residential buildings and architectural features in flows that lack fully developed turbulence. While these methods are effective for small structures, the extension of the approach for large and flexible structures is not possible yet. The purpose of this study is to investigate the role of turbulence in the response of tall buildings to extreme winds. In addition, the paper presents a detailed analysis to investigate the influence of upstream terrain conditions, wind direction angle (orientation), and the interference effect from the surrounding on the response of high-rise buildings. The methodology presented can be followed to help decision makers to choose among innovative solutions like aerodynamic mitigation, structural member size adjustment, and/or damping enhancement, with an objective to improve the resiliency and the serviceability of buildings.

  10. Influence of Turbulence, Orientation, and Site Configuration on the Response of Buildings to Extreme Wind

    Science.gov (United States)

    2014-01-01

    Atmospheric turbulence results from the vertical movement of air, together with flow disturbances around surface obstacles which make low- and moderate-level winds extremely irregular. Recent advancements in wind engineering have led to the construction of new facilities for testing residential homes at relatively high Reynolds numbers. However, the generation of a fully developed turbulence in these facilities is challenging. The author proposed techniques for the testing of residential buildings and architectural features in flows that lack fully developed turbulence. While these methods are effective for small structures, the extension of the approach for large and flexible structures is not possible yet. The purpose of this study is to investigate the role of turbulence in the response of tall buildings to extreme winds. In addition, the paper presents a detailed analysis to investigate the influence of upstream terrain conditions, wind direction angle (orientation), and the interference effect from the surrounding on the response of high-rise buildings. The methodology presented can be followed to help decision makers to choose among innovative solutions like aerodynamic mitigation, structural member size adjustment, and/or damping enhancement, with an objective to improve the resiliency and the serviceability of buildings. PMID:24701140

  11. Measurement methods of building structures deflections

    Directory of Open Access Journals (Sweden)

    Wróblewska Magdalena

    2018-01-01

    Full Text Available Underground mining exploitation is leading to the occurrence of deformations manifested by, in particular, sloping terrain. The structures situated on the deforming subsoil are subject to uneven subsidence which is leading in consequence to their deflection. Before a building rectification process takes place by, e.g. uneven raising, the structure's deflection direction and value is determined so that the structure is restored to its vertical position as a result of the undertaken remedial measures. Deflection can be determined by applying classical as well as modern measurement techniques. The article presents examples of measurement methods used considering the measured elements of building structures’ constructions and field measurements. Moreover, for a given example of a mining area, the existing deflections of buildings were compared with mining terrain sloping.

  12. Heavy components coupling effect on building response spectra generation

    International Nuclear Information System (INIS)

    Liu, T.H.; Johnson, E.R.

    1985-01-01

    This study investigates the dynamic coupling effect on the floor response spectra between the heavy components and the Reactor Interior (R/I) building in a PWR. The following cases were studied: (I) simplified models of one and two lump mass models representing building and heavy components, and (II) actual plant building and heavy component models. Response spectra are developed at building nodes for all models, using time-history analysis methods. Comparisons of response spectra from various models are made to observe the coupling effects. In some cases, this study found that the coupling would reduce the response spectra values in certain frequency regions even if the coupling is not required according to the above criteria. (orig./HP)

  13. Reduction of the dynamic response by aircraft crash on building structures

    International Nuclear Information System (INIS)

    Krutzik, N.J.

    1988-01-01

    Through the use of the double-shell concept the dynamic loads applied by a hypothetical aircraft impact as well as the response of the structure can be reduced significantly. Steel-fiber-reinforced concrete shells with thicknesses of about 0.8 m have a sufficient nonlinear capacity for loads applied by a military airplane such as the Phantom jet. The secondary impact after damage of the outer shell as well as the dynamic response of the structure can be additionally reduced using damping material supporting the impacted shell. Construction of the double shell design does not result in any practical problems. (orig./HP)

  14. Seismic response of base isolated auxiliary building with age related degradation

    International Nuclear Information System (INIS)

    Park, Jun Hee; Choun, Young Sun; Choi, In Kil

    2012-01-01

    The aging of an isolator affects not only the mechanical properties of the isolator but also the dynamic properties of the upper structure, such as the change in stiffness, deformation capacity, load bearing capacity, creep, and damping. Therefore, the seismic response of base isolated structures will change with time. The floor response in the base isolated nuclear power plants (NPPs) can be particularly changed because of the change in stiffness and damping for the isolator. The increased seismic response due to the aging of isolator can cause mechanical problems for many equipment located in the NPPs. Therefore, it is necessary to evaluate the seismic response of base isolated NPPs with age related degradation. In this study, the seismic responses for a base isolated auxiliary building of SHIN KORI 3 and 4 with age related degradation were investigated using a nonlinear time history analysis. Floor response spectrums (FRS) were presented with time for identifying the change in seismic demand under the aging of isolator

  15. Experimental building with new types of building envelope structures. Part 1: Structures/systems. Building system: Brick walls; Forsoegshus med nye typer klimaskaermskonstruktioner. Del 1: Konstruktioner/systemer - Byggesystem: Fuldmuret

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The house described in this report is one of several experimental houses forming part of the project 'Experimental buildings with new types of building envelope structures'. One purpose of the project is to demonstrate that it is possible to build typical single-family houses with an energy consumption that meets expected increased building regulations. Furthermore, it is important that the houses can be made securely as regards construction technology and within reasonable financial limits. Thus, the purpose is also to contribute to strengthen the development of improved building envelope structures. Another purpose is to carry out detailed measurements of energy consumption in order to validate thermal performance of future building envelope structures. The report describes the constructive design and energy systems of the house plus heat loss calculations and expected energy consumption. (BA)

  16. Study on vertical seismic response model of BWR-type reactor building

    International Nuclear Information System (INIS)

    Konno, T.; Motohashi, S.; Izumi, M.; Iizuka, S.

    1993-01-01

    A study on advanced seismic design for LWR has been carried out by the Nuclear Power Engineering Corporation (NUPEC), under the sponsorship of the Ministry of International Trade and Industry (MITI) of Japan. As a part of the study, it has been investigated to construct an accurate analytical model of reactor buildings for a seismic response analysis, which can reasonably represent dynamic characteristics of the building. In Japan, vibration models of reactor buildings for horizontal ground motion have been studied and examined through many simulation analyses for forced vibration tests and earthquake observations of actual buildings. And now it is possible to establish a reliable horizontal vibration model on the basis of multi-lumped mass and spring model. However, vertical vibration models have not been so much studied as horizontal models, due to less observed data for vertical motions. In this paper, the vertical seismic response models of a BWR-type reactor building including soil-structure interaction effect are numerically studied, by comparing the dynamic characteristics of (1) three dimensional finite element model, (2) multi-stick lumped mass model with a flexible base-mat, (3) multi-stick lumped mass model with a rigid base-mat and (4) single-stick lumped mass model. In particular, the BWR-type reactor building has the long span truss roof which is considered to be one of the critical members to vertical excitation. The modelings of the roof trusses are also studied

  17. Structural Analysis and Seismic Design for Cold Neutron Laboratory Building

    International Nuclear Information System (INIS)

    Wu, Sangik; Kim, Y. K.; Kim, H. R.

    2007-05-01

    This report describes all the major results of the dynamic structural analysis and seismic design for the Cold Neutron Laboratory Building which is classified in seismic class II. The results are summarized of the ground response spectrum as seismic input loads, mechanical properties of subsoil, the buoyancy stability due to ground water, the maximum displacement of the main frame under the seismic load and the member design. This report will be used as a basic design report to maintenance its structural integrity in future

  18. Environmental effect of structural solutions and building materials to a building

    International Nuclear Information System (INIS)

    Haapio, Appu; Viitaniemi, Pertti

    2008-01-01

    The field of building environmental assessment tools has become a popular research area over the past decade. However, how the service life of a building affects the results of the environmental assessment of a building has not been emphasised previously. The aim of this study is to analyse how different structural solutions and building materials affect the results of the environmental assessment of a whole building over the building's life cycle. Furthermore, how the length of the building's service life affects the results is analysed. The environmental assessments of 78 single-family houses were calculated for this study. The buildings have different wall insulations, claddings, window frames, and roof materials, and the length of the service life varies from 60 years up to 160 years. The current situation and the future of the environmental assessment of buildings are discussed. In addition, topics for further research are suggested; for example, how workmanship affects the service life and the environmental impact of a building should be studied

  19. Evaluating response modification factor (R for some types of steel structure

    Directory of Open Access Journals (Sweden)

    Doralba Valencia Restrepo

    2008-01-01

    Full Text Available Response modification factor (R, tabulated in the Colombian Design Code as NSR-98, is used in this paper for eva-luating internal member forces produced by design earthquake action on steel structures and the inconsistencies pre-sent when designing structures when 1% drift limits must be complied with. The article presents the design of 45 frames corresponding to the seismic resistance system of 5 buildings: 15 special moment frames (SMF, 15 special concentrically-braced frames (CBF and 15 eccentrically-braced frames (EBF. External loads and their combination were used in estimating internal loads and rigidity demands (1% drift were evaluated in line with NSR-98 requi-rements. Member strength requirements were evaluated by using the AISC-2005 seismic provisions for steel structu-red buildings. Modal pushover analysis was used for evaluating the response modification factor for the 45 given frames at different structural performance levels. It was found that this factor was not constant for any of the three structural systems (SMF, CBF and EBF suggested by NSR-98 and that the values of the response modification factor found in the present investigation were smaller than those tabulated in this design code governing everyday structural design. This would lead to significant errors being made in evaluating design forces, not only in the structures but in the support elements (base-plates, foundations, shear walls and any structures attached to buildings constructed in line with the seismic resistance system.

  20. Structural rehabilitation of old buildings

    CERN Document Server

    Guedes, João; Varum, Humberto

    2014-01-01

    The present book describes the different construction systems and structural materials and solutions within the main old buildings typologies, and it analyses the particularities of each of them, including mechanical properties, structural behaviour, typical damage patterns and collapse mechanisms. Common or pioneering intervention measures to repair and/or strengthen some of these structural elements are also reviewed.

  1. Torsional structural response from free-field ground motion

    International Nuclear Information System (INIS)

    Lam, P.C.; Scavuzzo, R.J.

    1979-01-01

    Torsional response of structures subjected to the action of both the free-field torsional inputs and external torque is investigated. By expanding the work of Scanlan, both lateral and torsional foundation inputs due to a travelling shear wave are derived from the free-field point motion. These free-field torsional motions are used as the basis of numerical studies. Response for different soil stiffness and structural characteristics are studied, as well as different dynamic models. In one dynamic model the structure is coupled to the soil using a compliance spring matrix and in the second model the structure coupled to an elastic half-space. Results of these two basic models are compared and found to be in good agreement. Finally, torsional structural response caused by torsional inputs is compared with lateral response caused by modified lateral inputs to determine the significance of torsional excitation on the seismic response of building structures. Numerical results show that these torsional seismic loads are as large or larger than those from modified lateral inputs. (orig.)

  2. Multicriteria Analysis of Assembling Buildings from Steel Frame Structures

    Science.gov (United States)

    Miniotaite, Ruta

    2017-10-01

    Steel frame structures are often used in the construction of public and industrial buildings. They are used for: all types of slope roofs; walls of newly-built public and industrial buildings; load bearing structures; roofs of renovated buildings. The process of assembling buildings from steel frame structures should be analysed as an integrated process influenced by such factors as construction materials and machinery used, the qualification level of construction workers, complexity of work, available finance. It is necessary to find a rational technological design solution for assembling buildings from steel frame structures by conducting a multiple criteria analysis. The analysis provides a possibility to evaluate the engineering considerations and find unequivocal solutions. The rational alternative of a complex process of assembling buildings from steel frame structures was found through multiple criteria analysis and multiple criteria evaluation. In multiple criteria evaluation of technological solutions for assembling buildings from steel frame structures by pairwise comparison method the criteria by significance are distributed as follows: durability is the most important criterion in the evaluation of alternatives; the price (EUR/unit of measurement) of a part of assembly process; construction workers’ qualification level (category); mechanization level of a part of assembling process (%), and complexity of assembling work (in points) are less important criteria.

  3. On-line structural response analysis: using the extended Kalman estimator/identifier

    International Nuclear Information System (INIS)

    Candy, J.V.

    1979-01-01

    This report disucsses the development of on-line state and parameter estimators used to analyze the structural response of buildings. The estimator/identifier is an extended Kalman filter (EKF), which has been applied with great success in other technological areas. It is shown that the EKF can perform quite well on simulated noisy structural response data

  4. Floor Response Evaluation for Auxiliary Building Subjected to Aircraft Impact Loading

    International Nuclear Information System (INIS)

    Shin, Sang Shup; Hahm, Daegi; Choi, Inkil

    2014-01-01

    These studies have been aimed to verify and ensure the safety of the targeted walls and structures especially in the viewpoint of the deterministic approach. However, a probabilistic safety assessment as well as deterministic approach for the damage of the internal component in the nuclear power plants (NPPs) subjected to aircraft crash is also needed. A probabilistic safety assessment for aircraft crash includes many uncertainties such as impact velocity, mass, impact location, shape, size, material etc. of aircraft. In this paper, an impact location was selected among the various parameters. This paper found the acceleration floor response spectra at specified locations (safety related components) on the target structure that assumed to be impact velocity 150m/s and maximum fuel for the specified aircraft model. In order to obtain the floor response in case of the crash with a various locations, the analyses for the auxiliary building subjected to aircraft impact were performed using Riera force history method and missile-target interaction method. The difference between responses in case of the building floor subjected to impact was occurred. Thus, in order to obtain the more accurate results, missile-target interaction method was used. This paper found the response at the selected point (node point No. 51). In order to probabilistic assessment for the safety related components, the assessment for a various parameters (velocity, mass, materials etc.) as well as impact locations should be needed

  5. Coupled vertical-rocking response of base-isolated structures

    International Nuclear Information System (INIS)

    Pan, T.C.; Kelly, J.M.

    1984-01-01

    A base-isolated building can have a small horizontal eccentricity between the center of mass of the superstructure and the center of rigidity of the supporting bearings. The structure can be modeled as a rigid block with tributary masses supported on massless rubber bearings placed at a constant elevation below the center of mass. Perturbation methods are implemented to find the dynamic characteristics for both the detuned and the perfectly tuned cases. The Green's functions for the displacement response of the system are derived for the undamped and the damped conditions. The response spectrum modal superposition method is used in estimating the maximum acceleration. A simple method, accounting for the effect of closely spaced modes, is proposed for combining modal maxima and results in an approximate single-degree-of-freedom solution. This approximate solution may be used for thepreliminary design of a base-isolated structure. Numerical results for a base-isolated building subjected to the vertical component of the El Centro earthquake of 1940 were carried out for comparison with analytical results. It is shown that the effect of rocking coupling on the vertical seismic response of baseisolated structures can generally be neglected because of the combined effects of the time lag between the maximum translational and rotational responses and the influence of damping in the isolation system

  6. Effect of nonlinearity of connecting dampers on vibration control of connected building structures

    Directory of Open Access Journals (Sweden)

    Masatoshi eKasagi

    2016-01-01

    Full Text Available The connection of two building structures with dampers is one of effective vibration control systems. In this vibration control system, both buildings have to possess different vibration properties in order to provide a higher vibration reduction performance. In addition to such condition of different vibration properties of both buildings, the connecting dampers also play an important role in the vibration control mechanism. In this paper, the effect of nonlinearity of connecting dampers on the vibration control of connected building structures is investigated in detail. A high-damping rubber damper and an oil damper with and without relief mechanism are treated. It is shown that, while the high-damping rubber damper is effective in a rather small deformation level, the linear oil damper is effective in a relatively large deformation level. It is further shown that, while the oil dampers reduce the response in the same phase as the case without dampers, the high-damping rubber dampers change the phase. The merit is that the high-damping rubber can reduce the damper deformation and keep the sufficient space between both buildings. This can mitigate the risk of building pounding.

  7. Measurements and evaluation of building response to ground motion at various stages of construction

    International Nuclear Information System (INIS)

    Honda, K.K.

    1976-01-01

    Architectural elements contribute significantly to the total seismic response of high-rise frame buildings. Although the characteristics of ground motion have considerable effect on the response of buildings, architectural elements increase the stiffness of the total system and reduce its period. The measurements also showed that partition influence is reduced over a period of time, as indicated by the lengthening of periods. At low levels of motion where the partitions contribute lateral stiffness to the system, they carry a proportional amount of the total lateral load and add sizable energy-absorbing capacity to the system. However, when the partitions are removed, the load formerly carried by the partitions is again transferred to the structural system. Because of the different response mode shapes of the models, the interstory drift at the first floor for the same roof displacement can vary significantly among models. In the models studied, the building without partitions at the first floor had the largest interstory drift

  8. A Review of Influence of Various Types of Structural Bracing to the Structural Performance of Buildings

    Science.gov (United States)

    Razak, S. M.; Kong, T. C.; Zainol, N. Z.; Adnan, A.; Azimi, M.

    2018-03-01

    Excessive lateral drift can contribute significantly towards crack formation, leading to structural damage. The structural damage will in turn reduce the capacity of the structure and weaken it from the intended design capacity. Generally, lateral drift is more pronounced in higher and longer structure, such as high rise buildings and bridges. A typical method employed to control lateral drift is structural bracing, which works by increasing stiffness and stability of structure. This paper reviews the influence of various types of structural bracing to structural performance of buildings. The history of structural bracing is visited and the differences between numerous structural bracing in term of suitability to different types of buildings and loading, mechanisms, technical details, advantages and limitations, and the overall effect on the structural behaviour and performance are dissected. Proper and efficient structural bracing is pertinent for each high rise building as this will lead towards safer, sustainable and more economical buildings, which are cheaper to maintain throughout the life of the buildings in the future.

  9. Seismic analysis of a PWR 900 reactor: study of reactor building with soil-structure interaction and evaluation of floor spectra

    International Nuclear Information System (INIS)

    Gantenbein, F.; Aguilar, J.

    1983-08-01

    The purpose of this paper is the evaluation of seismic response and floor spectra for a typical PWR 900 reactor building with respect to soil-structure interaction for soil stiffness). The typical PWR 900 reactor building consists of a concrete cylindrical external building and roof dome, a concrete internal structure (internals) on a common foundation mat as illustrated. The seismic response is obtained by SRSS method and floor spectra directly from ground spectrum and modal properties of the structure. Seismic responses and floor spectra computation is performed in the case of two different ground spectra: EDF spectrum (mean of oscillator spectra obtained from 8 californian records) normalized to 0.2 g, and DSN spectrum (typical of shallow seism) normalized to 0.3 g. The first section is devoted to internals' modelisation, the second one to the axisymmetric model of the reactor, the third one to the seismic response, the fourth one to floor spectra

  10. Automated detection of repeated structures in building facades

    Directory of Open Access Journals (Sweden)

    M. Previtali

    2013-10-01

    Full Text Available Automatic identification of high-level repeated structures in 3D point clouds of building façades is crucial for applications like digitalization and building modelling. Indeed, in many architectural styles building façades are governed by arrangements of objects into repeated patterns. In particular, façades are generally designed as the repetition of some few basic objects organized into interlaced and\\or concatenated grid structures. Starting from this key observation, this paper presents an algorithm for Repeated Structure Detection (RSD in 3D point clouds of building façades. The presented methodology consists of three main phases. First, in the point cloud segmentation stage (i the building façade is decomposed into planar patches which are classified by means of some weak prior knowledge of urban buildings formulated in a classification tree. Secondly (ii, in the element clustering phase detected patches are grouped together by means of a similarity function and pairwise transformations between patches are computed. Eventually (iii, in the structure regularity estimation step the parameters of repeated grid patterns are calculated by using a Least- Squares optimization. Workability of the presented approach is tested using some real data from urban scenes.

  11. Two-Graph Building Interior Representation for Emergency Response Applications

    Science.gov (United States)

    Boguslawski, P.; Mahdjoubi, L.; Zverovich, V.; Fadli, F.

    2016-06-01

    Nowadays, in a rapidly developing urban environment with bigger and higher public buildings, disasters causing emergency situations and casualties are unavoidable. Preparedness and quick response are crucial issues saving human lives. Available information about an emergency scene, such as a building structure, helps for decision making and organizing rescue operations. Models supporting decision-making should be available in real, or near-real, time. Thus, good quality models that allow implementation of automated methods are highly desirable. This paper presents details of the recently developed method for automated generation of variable density navigable networks in a 3D indoor environment, including a full 3D topological model, which may be used not only for standard navigation but also for finding safe routes and simulating hazard and phenomena associated with disasters such as fire spread and heat transfer.

  12. TWO-GRAPH BUILDING INTERIOR REPRESENTATION FOR EMERGENCY RESPONSE APPLICATIONS

    Directory of Open Access Journals (Sweden)

    P. Boguslawski

    2016-06-01

    Full Text Available Nowadays, in a rapidly developing urban environment with bigger and higher public buildings, disasters causing emergency situations and casualties are unavoidable. Preparedness and quick response are crucial issues saving human lives. Available information about an emergency scene, such as a building structure, helps for decision making and organizing rescue operations. Models supporting decision-making should be available in real, or near-real, time. Thus, good quality models that allow implementation of automated methods are highly desirable. This paper presents details of the recently developed method for automated generation of variable density navigable networks in a 3D indoor environment, including a full 3D topological model, which may be used not only for standard navigation but also for finding safe routes and simulating hazard and phenomena associated with disasters such as fire spread and heat transfer.

  13. Structural design of SBWR reactor building complex using microcomputers

    International Nuclear Information System (INIS)

    Mandagi, K.; Rajagopal, R.S.; Sawhney, P.S.; Gou, P.F.

    1993-01-01

    The design concept of Simplified Boiling Water Reactor (SBWR) plant is based on simplicity and passive features to enhance safety and reliability, improve performance, and increase economic viability. The SBWR utilizes passive systems such as Gravity Driven Core-Cooling System (GDCS) and Passive Containment Cooling System (PCCS). To suit these design features the Reactor Building (RB) complex of the SBWR is configured as an integrated structure consisting of a cylindrical Reinforced Concrete Containment Vessel (RCCV) surrounded by square reinforced concrete safety envelope and outer box structures, all sharing a common reinforced concrete basemat. This paper describes the structural analysis and design aspects of the RB complex. A 3D STARDYNE finite element model has been developed for the structural analysis of the complex using a PC Compaq 486/33L microcomputer. The structural analysis is performed for service and factored load conditions for the applicable loading combinations. The dynamic responses of containment structures due to pool hydrodynamic loads have been calculated by an axisymmetric shell model using COSMOS/M program. The RCCV is designed in accordance with ASME Section 3, Division 2 Code. The rest of the RB which is classified as Seismic Category 1 structure is designed in accordance with the ACI 349 Code. This paper shows that microcomputers can be efficiently used for the analysis and design of large and complex structures such as RCCV and Reactor Building complex. The use of microcomputers can result in significant savings in the computational cost compared with that of mainframe computers

  14. 30 CFR 57.4530 - Exits for surface buildings and structures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Exits for surface buildings and structures. 57... Fire Prevention and Control Installation/construction/maintenance § 57.4530 Exits for surface buildings and structures. Surface buildings or structures in which persons work shall have a sufficient number...

  15. Shock vibration and damage responses of primary auxiliary buildings from aircraft impact

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sang Shup [Korea Atomic Energy Research Institute, 1045 Daeduk-daero, Dukjin-dong, Yuseong-gu, Daejeon 305-303 (Korea, Republic of); Department of Civil and Environmental Engineering, Hanyang University, Seoul 133-791 (Korea, Republic of); Hahm, Daegi [Korea Atomic Energy Research Institute, 1045 Daeduk-daero, Dukjin-dong, Yuseong-gu, Daejeon 305-303 (Korea, Republic of); Park, Taehyo, E-mail: cepark@hanyang.ac.kr [Department of Civil and Environmental Engineering, Hanyang University, Seoul 133-791 (Korea, Republic of)

    2016-12-15

    Highlights: • Aircraft impact analyses of PABs were performed using both the force-time history method and missile-target interaction method. • The jet fuel was considered by using the added mass modeling method and SPH method, respectively. • The FRS and the structural integrity of the external wall of the PABs against an aircraft impact were analyzed. - Abstract: Safety assessments on nuclear power plants (NPPs) subjected to an aircraft impact (AI) caused by terrorists are pivotal focuses for amelioration of present. To date, most studies have mainly focused on structure responses and the integrity of the containment building at a nuclear island (NI) subjected to AI. However, the safety assessment of internal equipment and components by shock vibration as well as the structure damage induced by AI are also important. In this study, aircraft impact analyses (AIA) of primary auxiliary buildings (PABs) were carried out using both the force–time history method and the missile–target interaction method. For the AIA, the jet fuel was taken into account by using the added mass modeling method and the smooth particles hydrodynamics (SPH) method, respectively. In addition, the floor response spectra (FRS) and the structural integrity of the external wall of the PAB against an AI were analyzed. Finally, the difference in the FRS at the location of the components on both sides of the bay was analyzed.

  16. Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Evaluation of Equivalent Linearization Method

    Directory of Open Access Journals (Sweden)

    Massimiliano Ferraioli

    2016-01-01

    Full Text Available Although the most commonly used isolation systems exhibit nonlinear inelastic behaviour, the equivalent linear elastic analysis is commonly used in the design and assessment of seismic-isolated structures. The paper investigates if the linear elastic model is suitable for the analysis of a seismically isolated multiple building structure. To this aim, its computed responses were compared with those calculated by nonlinear dynamic analysis. A common base isolation plane connects the isolation bearings supporting the adjacent structures. In this situation, the conventional equivalent linear elastic analysis may have some problems of accuracy because this method is calibrated on single base-isolated structures. Moreover, the torsional characteristics of the combined system are significantly different from those of separate isolated buildings. A number of numerical simulations and parametric studies under earthquake excitations were performed. The accuracy of the dynamic response obtained by the equivalent linear elastic model was calculated by the magnitude of the error with respect to the corresponding response considering the nonlinear behaviour of the isolation system. The maximum displacements at the isolation level, the maximum interstorey drifts, and the peak absolute acceleration were selected as the most important response measures. The influence of mass eccentricity, torsion, and high-modes effects was finally investigated.

  17. Seismic response analysis of a 13-story steel moment-framed building in Alhambra, California

    Science.gov (United States)

    Rodgers, Janise E.; Sanli, Ahmet K.; Çelebi, Mehmet

    2004-01-01

    The seismic performance of steel moment-framed buildings has been of particular interest since brittle fractures were discovered at the beam-column connections of some frames following the M6.7 1994 Northridge earthquake. This report presents an investigation of the seismic behavior of an instrumented 13-story steel moment frame building located in the greater Los Angeles area of California. An extensive strong motion dataset, ambient vibration data, engineering drawings and earthquake damage reports are available for this building. The data are described and subsequently analyzed. The results of the analyses show that the building response is more complex than would be expected from its highly symmetrical geometry. The building's response is characterized by low damping in the fundamental mode, larger peak accelerations in the intermediate stories than at the roof, extended periods of vibration after the cessation of strong input shaking, beating in the response, and significant torsion during strong shaking at the top of the concrete piers which extend from the basement to the second floor. The analyses of the data and all damage detection methods employed except one method based on system identification indicate that the response of the structure was elastic in all recorded earthquakes. These findings are in general agreement with the results of intrusive inspections (meaning fireproofing and architectural finishes were removed) conducted on approximately 5 percent of the moment connections following the Northridge earthquake, which found no earthquake damage.

  18. Structured building model reduction toward parallel simulation

    Energy Technology Data Exchange (ETDEWEB)

    Dobbs, Justin R. [Cornell University; Hencey, Brondon M. [Cornell University

    2013-08-26

    Building energy model reduction exchanges accuracy for improved simulation speed by reducing the number of dynamical equations. Parallel computing aims to improve simulation times without loss of accuracy but is poorly utilized by contemporary simulators and is inherently limited by inter-processor communication. This paper bridges these disparate techniques to implement efficient parallel building thermal simulation. We begin with a survey of three structured reduction approaches that compares their performance to a leading unstructured method. We then use structured model reduction to find thermal clusters in the building energy model and allocate processing resources. Experimental results demonstrate faster simulation and low error without any interprocessor communication.

  19. An investigation of soil-structure interaction effects observed at the MIT Green Building

    Science.gov (United States)

    Taciroglu, Ertugrul; Çelebi, Mehmet; Ghahari, S. Farid; Abazarsa, Fariba

    2016-01-01

    The soil-foundation impedance function of the MIT Green Building is identified from its response signals recorded during an earthquake. Estimation of foundation impedance functions from seismic response signals is a challenging task, because: (1) the foundation input motions (FIMs) are not directly measurable, (2) the as-built properties of the super-structure are only approximately known, and (3) the soil-foundation impedance functions are inherently frequency-dependent. In the present study, aforementioned difficulties are circumvented by using, in succession, a blind modal identification (BMID) method, a simplified Timoshenko beam model (TBM), and a parametric updating of transfer functions (TFs). First, the flexible-base modal properties of the building are identified from response signals using the BMID method. Then, a flexible-base TBM is updated using the identified modal data. Finally, the frequency-dependent soil-foundation impedance function is estimated by minimizing the discrepancy between TFs (of pairs instrumented floors) that are (1) obtained experimentally from earthquake data and (2) analytically from the updated TBM. Using the fully identified flexible-base TBM, the FIMs as well as building responses at locations without instruments can be predicted, as demonstrated in the present study.

  20. Seismic Assessment of Buildings: Proposal of a New Modified Uncoupled Modal Response History Analysis

    International Nuclear Information System (INIS)

    Jerez, Sandra; Mebarki, Ahmed

    2010-01-01

    This paper develops a new modified uncoupled modal response history analysis (M-UMRHA) in order to study the seismic behavior of structures. It aims to provide an acceptable accuracy with reduced calculation duration in comparison to complete analysis, i.e. the THA. The proposed method improves the existing UMRHA, developed by Chopra and Goel [1], by considering an energy based approach to build the capacity curve [2] and a pseudo-adaptive feature to account for changes in modal shapes after yielding, motivated by an adaptive method [3]. Validation is made by comparison with NLTHA as well as other simplified methods. Low and medium-rise RC buildings were analyzed under real ground motion records. Results show good estimates of structural parameters and give good correlation between damage and story displacements as well as drifts. Like other simplified methods, accuracy decreases in the inelastic domain. However, this procedure gives acceptable estimates of structural response with a few additional calculations and it has the potential to be used in large scale studies, and probabilistic approaches.

  1. Synthetic building materials for transport buildings and structures

    Science.gov (United States)

    Gerasimova, Vera

    2017-10-01

    The most effective building materials account for the highest growth not only in construction of residential and public buildings, but also other capital projects including roadways, bridges, drainage, communications and other engineering projects. Advancement in the technology of more efficient and ecologically responsible insulation materials have been a priority for safety, minimal maintenance and longevity of finished construction projects. The practical use of modern building materials such as insulation, sound reduction and low energy consumption are a benefit in cost and application compared to the use of outdated heavier and labor-intensive materials. The most efficient way for maximizing insolation and sound proofing should be done during the design stages of the project according to existing codes and regulations that are required by Western Government. All methods and materials that are used need to be optimized in order to reach a high durability and low operational and maintenance cost exceeding more than 50 years of the life of the building, whether it is for public, industrial or residential use. Western construction techniques and technologies need to be applied and adapted by the Russian Federation to insure the most productive successful methods are being implemented. The issues of efficient insulation materials are outlined in this article.

  2. Modeling of Dynamic Responses in Building Insulation

    Directory of Open Access Journals (Sweden)

    Anna Antonyová

    2015-10-01

    Full Text Available In this research a measurement systemwas developedfor monitoring humidity and temperature in the cavity between the wall and the insulating material in the building envelope. This new technology does not disturb the insulating material during testing. The measurement system can also be applied to insulation fixed ten or twenty years earlier and sufficiently reveals the quality of the insulation. A mathematical model is proposed to characterize the dynamic responses in the cavity between the wall and the building insulation as influenced by weather conditions.These dynamic responses are manifested as a delay of both humidity and temperature changes in the cavity when compared with the changes in the ambient surrounding of the building. The process is then modeled through numerical methods and statistical analysis of the experimental data obtained using the new system of measurement.

  3. Assessment of structural reliability of precast concrete buildings

    Directory of Open Access Journals (Sweden)

    Koyankin Alexandr

    2018-01-01

    Full Text Available Precast housing construction is currently being under rapid development, however, reliability of building structures made from precast reinforced concrete cannot be assessed rationally due to insufficient research data on that subject. In this regard, experimental and numerical studies were conducted to assess structural reliability of precast buildings as described in the given paper. Experimental studies of full-scale and model samples were conducted; numerical studies were held based on finite element models using “Lira” software. The objects under study included fragment of flooring of a building under construction, full-size fragment of flooring, full-scale models of precast cross-beams-to-columns joints and joints between hollow-core floor slabs and precast and cast-in-place cross-beams. Conducted research enabled to perform an objective assessment of structural reliability of precast buildings.

  4. Seismic soil structure interaction analysis for asymmetrical buildings supported on piled raft for the 2015 Nepal earthquake

    Science.gov (United States)

    Badry, Pallavi; Satyam, Neelima

    2017-01-01

    Seismic damage surveys and analyses conducted on modes of failure of structures during past earthquakes observed that the asymmetrical buildings show the most vulnerable effect throughout the course of failures (Wegner et al., 2009). Thus, all asymmetrical buildings significantly fails during the shaking events and it is really needed to focus on the accurate analysis of the building, including all possible accuracy in the analysis. Apart from superstructure geometry, the soil behavior during earthquake shaking plays a pivotal role in the building collapse (Chopra, 2012). Fixed base analysis where the soil is considered to be infinitely rigid cannot simulate the actual scenario of wave propagation during earthquakes and wave transfer mechanism in the superstructure (Wolf, 1985). This can be well explained in the soil structure interaction analysis, where the ground movement and structural movement can be considered with the equal rigor. In the present study the object oriented program has been developed in C++ to model the SSI system using the finite element methodology. In this attempt the seismic soil structure interaction analysis has been carried out for T, L and C types piled raft supported buildings in the recent 25th April 2015 Nepal earthquake (M = 7.8). The soil properties have been considered with the appropriate soil data from the Katmandu valley region. The effect of asymmetry of the building on the responses of the superstructure is compared with the author's research work. It has been studied/observed that the shape or geometry of the superstructure governs the response of the superstructure subjected to the same earthquake load.

  5. Earthquake response of nuclear reactor buildings deeply embedded in soil

    International Nuclear Information System (INIS)

    Masao, T.; Takasaki, Y.; Hirasawa, M.; Okajima, M.; Yamamoto, S.; Kawata, E.; Koori, Y.; Ochiai, S.; Shimizu, N.

    1980-01-01

    This paper is concerned with experimental and analytical studies to investigate dynamic behavior of deeply embedded structures such as nuclear reactor buildings. The principal points studied are as follows: (1) Examination of stiffness and radiation damping effects according to embedded depth, (2) verification for distributions of earth pressure according to embedded depth, (3) differences of response characteristics during oscillation according to embedded depth, and (4) proposal of an analytical method for seismic design. Experimental studies were performed by two ways: forced vibration test, and earthquake observation against a rigid body model embedded in soil. Three analytical procedures were performed to compare experimental results and to examine the relation between each procedure. Finally, the dynamic behavior for nuclear reactor buildings with different embedded depths were evaluated by an analytical method. (orig.)

  6. Neighborhood structure effects on the Dynamic response of soil-structure interaction by harmonic analysis

    Directory of Open Access Journals (Sweden)

    Pan Dan-guang

    2015-01-01

    Full Text Available For realizing the variation of structural dynamic characteristics due to neighbor structure in buildings group, the surface structure is idealized as an equivalent single degree of freedom system with rigid base whose site consists of a single homogeneous layer. Based on the model, a equivalent method on the equivalent seismic excitation is proposed. Then, the differences of seismic response and equivalent seismic input between soil - structure interaction (SSI system and structure -soil-structure interaction (SSSI system are investigated by harmonic analysis. The numerical results show that dynamic responses would be underestimated in SSSI system when the forcing frequencies are close to the Natural frequency if the effects of neighborhood structure were ignored. Neighborhood structure would make the translational displacement increase and rocking vibration decrease. When establishing an effective seismic input, it is necessary to consider the impact of inertia interaction.

  7. FEM Updating of the Heritage Court Building Structure

    DEFF Research Database (Denmark)

    Ventura, C. E.; Brincker, Rune; Dascotte, E.

    2001-01-01

    . The starting model of the structure was developed from the information provided in the design documentation of the building. Different parameters of the model were then modified using an automated procedure to improve the correlation between measured and calculated modal parameters. Careful attention......This paper describes results of a model updating study conducted on a 15-storey reinforced concrete shear core building. The output-only modal identification results obtained from ambient vibration measurements of the building were used to update a finite element model of the structure...

  8. RESRAD-Build: A model to estimate dose from contaminated structures. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    The RESRAD-BUILD model is an exposure pathway and analysis code used to determine whether radiologically contaminated buildings and structures can be free released for a specific land use (e.g., residential or industrial). The model provides estimates of dose to a hypothetical receptor from the structure. The RESRAD-BUILD technology can calculate dose from variety of site-specific hypothetical scenarios, decay-time intervals, and radionuclides. When using the RESRAD-BUILD code, specific project assumptions must be developed with the appropriate regulatory agencies, especially the cleanup criteria and the exposure scenario to be used. The C Reactor demonstration of RESRAD-BUILD modeled hypothetical future use of below grade portions of the reactor building complex. A residential exposure scenario with a cleanup criteria of 15 mrem/yr above background (Environmental Protection Agency [EPA] draft guidance) was used to coordinate decommissioning with adjacent ongoing remedial actions conducted in accordance with an existing Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) Record of Decision. This paper gives a description of the technology and discusses its performance, applications, cost, regulatory and policy issues, and lessons learned

  9. RESRAD-BUILD: A model to estimate dose from contaminated structures. Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    The RESRAD-BUILD model is an exposure pathway and analysis code used to determine whether radiologically contaminated buildings and structures can be free released for a specific land use (e.g., residential or industrial). The model provides estimates of dose to a hypothetical receptor from the structure. The RESRAD-BUILD technology can calculate dose from variety of site-specific hypothetical scenarios, decay-time intervals, and radionuclides. When using the RESRAD-BUILD code, specific project assumptions must be developed with the appropriate regulatory agencies, especially the cleanup criteria and the exposure scenario to be used. The C Reactor demonstration of RESRAD-BUILD modeled hypothetical future use of below grade portions of the reactor building complex. A residential exposure scenario with a cleanup criteria of 15 mrem/yr above background (Environmental Protection Agency [EPA] draft guidance) was used to coordinate decommissioning with adjacent ongoing remedial actions conducted in accordance with an existing Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) Record of Decision. This paper gives a description of the technology and discusses its performance, applications, cost, regulatory and policy issues, and lessons learned.

  10. Optimal Technology Investment and Operation in Zero-Net-Energy Buildings with Demand Response

    International Nuclear Information System (INIS)

    Stadler, Michael; Siddiqui, Afzal; Marnay, Chris; Hirohisa, Aki; Lai, Judy

    2009-01-01

    The US Department of Energy has launched the Zero-Net-Energy (ZNE) Commercial Building Initiative (CBI) in order to develop commercial buildings that produce as much energy as they use. Its objective is to make these buildings marketable by 2025 such that they minimize their energy use through cutting-edge energy-efficient technologies and meet their remaining energy needs through on-site renewable energy generation. We examine how such buildings may be implemented within the context of a cost- or carbon-minimizing microgrid that is able to adopt and operate various technologies, such as photovoltaic (PV) on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and passive/demand-response technologies. We use a mixed-integer linear program (MILP) that has a multi-criteria objective function: the minimization of a weighted average of the building's annual energy costs and carbon/CO2 emissions. The MILP's constraints ensure energy balance and capacity limits. In addition, constraining the building's energy consumed to equal its energy exports enables us to explore how energy sales and demand-response measures may enable compliance with the CBI. Using a nursing home in northern California and New York with existing tariff rates and technology data, we find that a ZNE building requires ample PV capacity installed to ensure electricity sales during the day. This is complemented by investment in energy-efficient combined heat and power equipment, while occasional demand response shaves energy consumption. A large amount of storage is also adopted, which may be impractical. Nevertheless, it shows the nature of the solutions and costs necessary to achieve ZNE. For comparison, we analyze a nursing home facility in New York to examine the effects of a flatter tariff structure and different load profiles. It has trouble reaching ZNE status and its load reductions as well as efficiency measures need to be more effective than those in the CA case

  11. Dynamic characteristics and structural response of the SWR 1000 under earthquake loading conditions

    International Nuclear Information System (INIS)

    Bielor, E.; Brettschuh, W.; Krutzik, N.J.; Tropp, R.

    2001-01-01

    Based on the conceptual design documentation of the SWR 1000 reactor building as well as specified representative seismological, and soil-dynamic input data, corresponding to prospective sites as a basis, the dynamic characteristics, as well as the in-structure dynamic response of the coupled vibrating structures have been elaborated. The structural design analysis was based on a 3-dimensional mathematical model of the building in which all details of the internal structures as well as the containment including the water in the pools were represented adequately. In order to demonstrate the influence of the soil-structure interaction effects on the dynamic response results, the soil was represented by two different assumptions. At first, considering the state of the art procedures, assuming frequency independent soil capabilities (equivalent stiffnesses and damping values), time domain calculations were carried out. In the second step, based on the frequency-dependency of the soil capabilities, frequency domain calculations were performed. The structural responses obtained by means of both procedures and the same mathematical model of the structures were evaluated and compared. The suitability of the preliminary design concept are discussed and the structural response results obtained on the basis of the bearing capacity and the stresses in the characteristic regions of the structure

  12. Pros and cons of rotating ground motion records to fault-normal/parallel directions for response history analysis of buildings

    Science.gov (United States)

    Kalkan, Erol; Kwong, Neal S.

    2014-01-01

    According to the regulatory building codes in the United States (e.g., 2010 California Building Code), at least two horizontal ground motion components are required for three-dimensional (3D) response history analysis (RHA) of building structures. For sites within 5 km of an active fault, these records should be rotated to fault-normal/fault-parallel (FN/FP) directions, and two RHAs should be performed separately (when FN and then FP are aligned with the transverse direction of the structural axes). It is assumed that this approach will lead to two sets of responses that envelope the range of possible responses over all nonredundant rotation angles. This assumption is examined here, for the first time, using a 3D computer model of a six-story reinforced-concrete instrumented building subjected to an ensemble of bidirectional near-fault ground motions. Peak values of engineering demand parameters (EDPs) were computed for rotation angles ranging from 0 through 180° to quantify the difference between peak values of EDPs over all rotation angles and those due to FN/FP direction rotated motions. It is demonstrated that rotating ground motions to FN/FP directions (1) does not always lead to the maximum responses over all angles, (2) does not always envelope the range of possible responses, and (3) does not provide maximum responses for all EDPs simultaneously even if it provides a maximum response for a specific EDP.

  13. Structural acceptance criteria Remote Handling Building Tritium Extraction Facility

    Energy Technology Data Exchange (ETDEWEB)

    Mertz, G.

    1999-12-16

    This structural acceptance criteria contains the requirements for the structural analysis and design of the Remote Handling Building (RHB) in the Tritium Extraction Facility (TEF). The purpose of this acceptance criteria is to identify the specific criteria and methods that will ensure a structurally robust building that will safely perform its intended function and comply with the applicable Department of Energy (DOE) structural requirements.

  14. Structural acceptance criteria Remote Handling Building Tritium Extraction Facility

    International Nuclear Information System (INIS)

    Mertz, G.

    1999-01-01

    This structural acceptance criteria contains the requirements for the structural analysis and design of the Remote Handling Building (RHB) in the Tritium Extraction Facility (TEF). The purpose of this acceptance criteria is to identify the specific criteria and methods that will ensure a structurally robust building that will safely perform its intended function and comply with the applicable Department of Energy (DOE) structural requirements

  15. Open Automated Demand Response for Small Commerical Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, June Han; Piette, Mary Ann; Koch, Ed; Hennage, Dan

    2009-05-01

    This report characterizes small commercial buildings by market segments, systems and end-uses; develops a framework for identifying demand response (DR) enabling technologies and communication means; and reports on the design and development of a low-cost OpenADR enabling technology that delivers demand reductions as a percentage of the total predicted building peak electric demand. The results show that small offices, restaurants and retail buildings are the major contributors making up over one third of the small commercial peak demand. The majority of the small commercial buildings in California are located in southern inland areas and the central valley. Single-zone packaged units with manual and programmable thermostat controls make up the majority of heating ventilation and air conditioning (HVAC) systems for small commercial buildings with less than 200 kW peak electric demand. Fluorescent tubes with magnetic ballast and manual controls dominate this customer group's lighting systems. There are various ways, each with its pros and cons for a particular application, to communicate with these systems and three methods to enable automated DR in small commercial buildings using the Open Automated Demand Response (or OpenADR) communications infrastructure. Development of DR strategies must consider building characteristics, such as weather sensitivity and load variability, as well as system design (i.e. under-sizing, under-lighting, over-sizing, etc). Finally, field tests show that requesting demand reductions as a percentage of the total building predicted peak electric demand is feasible using the OpenADR infrastructure.

  16. Response of a 42-storey steel-frame building to the Ms = 7.1 Loma Prieta earthquake

    Science.gov (United States)

    Safak, E.

    1993-01-01

    A set of 14 acceleration records was obtained from a 42-storey steel-frame building, the Chevron Building, in San Francisco during the Ms = 7.1 Loma Prieta earthquake of 17 October 1989. Data were analysed using a system identification method based on the discretetime linear filtering, and the least-squares estimation techniques. The results show that the response of the building is dominated by two modes: a translational mode in the weaker (southwest-northeast) principal direction of the building at 0.16 Hz with 5% damping, and a translational-torsional mode along the east-west diagonal of the building's cross-section at 0.20 Hz with 7% damping. There are significant contributions from higher modes at 0.54 Hz, 0.62 Hz, 1.02 Hz and 1.09 Hz. All the modes incorporate some torsion, but the amplitudes of torsional components are small, about 10% of translational amplitudes. Soil-structure interaction influences the vibrations near 1.0 Hz. The contribution of soil-structure interaction to the peak displacements of the building is significant, particularly at lower floors. ?? 1993.

  17. Analysis of the structural design process of the adaptive reuse of building structures

    NARCIS (Netherlands)

    Pasterkamp, S.

    2014-01-01

    In the field of structural building engineering there is a market shift taking place as a result of the growing number of buildings that are listed as cultural heritage, secularization, the economic situation and the increasing office vacancy rate in Europe and the US. More and more structural

  18. Building Quakes: Detection of Weld Fractures in Buildings using High-Frequency Seismic Techniques

    Science.gov (United States)

    Heckman, V.; Kohler, M. D.; Heaton, T. H.

    2009-12-01

    Catastrophic fracture of welded beam-column connections in buildings was observed in the Northridge and Kobe earthquakes. Despite the structural importance of such connections, it can be difficult to locate damage in structural members underneath superficial building features. We have developed a novel technique to locate fracturing welds in buildings in real time using high-frequency information from seismograms. Numerical and experimental methods were used to investigate an approach for detecting the brittle fracture of welds of beam-column connections in instrumented steel moment-frame buildings through the use of time-reversed Green’s functions and wave propagation reciprocity. The approach makes use of a prerecorded catalogue of Green’s functions for an instrumented building to detect high-frequency failure events in the building during a later earthquake by screening continuous data for the presence of one or more of the events. This was explored experimentally by comparing structural responses of a small-scale laboratory structure under a variety of loading conditions. Experimentation was conducted on a polyvinyl chloride frame model structure with data recorded at a sample rate of 2000 Hz using piezoelectric accelerometers and a 24-bit digitizer. Green’s functions were obtained by applying impulsive force loads at various locations along the structure with a rubber-tipped force transducer hammer. We performed a blind test using cross-correlation techniques to determine if it was possible to use the catalogue of Green’s functions to pinpoint the absolute times and locations of subsequent, induced failure events in the structure. A finite-element method was used to simulate the response of the model structure to various source mechanisms in order to determine the types of elastic waves that were produced as well as to obtain a general understanding of the structural response to localized loading and fracture.

  19. Performance evaluation of existing building structure with pushover analysis

    Science.gov (United States)

    Handana, MAP; Karolina, R.; Steven

    2018-02-01

    In the management of the infrastructure of the building, during the period of buildings common building damage as a result of several reasons, earthquakes are common. The building is planned to work for a certain service life. But during the certain service life, the building vulnerable to damage due to various things. Any damage to cultivate can be detected as early as possible, because the damage could spread, triggering and exacerbating the latest. The newest concept to earthquake engineering is Performance Based Earthquake Engineering (PBEE). PBEE divided into two, namely Performance Based Seismic Design (PBSD) and Performance Based Seismic Evaluation (PBSE). Evaluation on PBSE one of which is the analysis of nonlinear pushover. Pushover analysis is a static analysis of nonlinear where the influence of the earthquake plan on building structure is considered as burdens static catch at the center of mass of each floor, which it was increased gradually until the loading causing the melting (plastic hinge) first within the building structure, then the load increases further changes the shapes of post-elastic large it reached the condition of elastic. Then followed melting (plastic hinge) in the location of the other structured.

  20. Elementary structural building blocks encountered in silicon surface reconstructions

    International Nuclear Information System (INIS)

    Battaglia, Corsin; Monney, Claude; Didiot, Clement; Schwier, Eike Fabian; Garnier, Michael Gunnar; Aebi, Philipp; Gaal-Nagy, Katalin; Onida, Giovanni

    2009-01-01

    Driven by the reduction of dangling bonds and the minimization of surface stress, reconstruction of silicon surfaces leads to a striking diversity of outcomes. Despite this variety even very elaborate structures are generally comprised of a small number of structural building blocks. We here identify important elementary building blocks and discuss their integration into the structural models as well as their impact on the electronic structure of the surface. (topical review)

  1. Simquake 3: Seismic interactions between building structures and rock-socketed foundations: Final report

    International Nuclear Information System (INIS)

    Howard, G.E.; Chitty, D.E.; Oleck, R.F.

    1988-04-01

    It has long been recognized that soil-structure interaction can significantly influence the earthquake response of massive structures such as nuclear power plant reactor buildings. The linear analysis methods that are widely used to model interaction phenomena can result in often unrecognized safety margins in design for earthquake excitation. Use of improved interaction models which capture nonlinear characteristics of interaction---such as energy dissipation and significant changes in stiffness---can provide realistic predictions of the earthquake loads imposed on nuclear power plant structures and equipment, supplying an improved basis for seismic design review. This report documents the results of a research effort investigating the soil-structure (or structure-media) interaction of reinforced concrete structures founded in backfilled rock sockets. The objectives of the research, which included field testing with semi-scale structural models, were: to examine the influence of the backfilled socket on structural dynamic response; and to develop an experimental data base for the benchmarking of computer simulation procedures

  2. Models test on dynamic structure-structure interaction of nuclear power plant buildings

    International Nuclear Information System (INIS)

    Kitada, Y.; Hirotani, T.

    1999-01-01

    A reactor building of an NPP (nuclear power plant) is generally constructed closely adjacent to a turbine building and other buildings such as the auxiliary building, and in increasing numbers of NPPs, multiple plants are being planned and constructed closely on a single site. In these situations, adjacent buildings are considered to influence each other through the soil during earthquakes and to exhibit dynamic behaviour different from that of separate buildings, because those buildings in NPP are generally heavy and massive. The dynamic interaction between buildings during earthquake through the soil is termed here as 'dynamic cross interaction (DCI)'. In order to comprehend DCI appropriately, forced vibration tests and earthquake observation are needed using closely constructed building models. Standing on this background, Nuclear Power Engineering Corporation (NUPEC) had planned the project to investigate the DCI effect in 1993 after the preceding SSI (soil-structure interaction) investigation project, 'model tests on embedment effect of reactor building'. The project consists of field and laboratory tests. The field test is being carried out using three different building construction conditions, e.g. a single reactor building to be used for the comparison purposes as for a reference, two same reactor buildings used to evaluate pure DCI effects, and two different buildings, reactor and turbine building models to evaluate DCI effects under the actual plant conditions. Forced vibration tests and earthquake observations are planned in the field test. The laboratory test is planned to evaluate basic characteristics of the DCI effects using simple soil model made of silicon rubber and structure models made of aluminum. In this test, forced vibration tests and shaking table tests are planned. The project was started in April 1994 and will be completed in March 2002. This paper describes an outline and the summary of the current status of this project. (orig.)

  3. Studies on Pounding Response Considering Structure-Soil-Structure Interaction under Seismic Loads

    Directory of Open Access Journals (Sweden)

    Peizhen Li

    2017-12-01

    Full Text Available Pounding phenomena considering structure–soil–structure interaction (SSSI under seismic loads are investigated in this paper. Based on a practical engineering project, this work presents a three-dimensional finite element numerical simulation method using ANSYS software. According to Chinese design code, the models of adjacent shear wall structures on Shanghai soft soil with the rigid foundation, box foundation and pile foundation are built respectively. In the simulation, the Davidenkov model of the soil skeleton curve is assumed for soil behavior, and the contact elements with Kelvin model are adopted to simulate pounding phenomena between adjacent structures. Finally, the dynamic responses of adjacent structures considering the pounding and SSSI effects are analyzed. The results show that pounding phenomena may occur, indicating that the seismic separation requirement for adjacent buildings of Chinese design code may not be enough to avoid pounding effect. Pounding and SSSI effects worsen the adjacent buildings’ conditions because their acceleration and shear responses are amplified after pounding considering SSSI. These results are significant for studying the effect of pounding and SSSI phenomena on seismic responses of structures and national sustainable development, especially in earthquake prevention and disaster reduction.

  4. Seismic Response of 3D Steel Buildings considering the Effect of PR Connections and Gravity Frames

    Directory of Open Access Journals (Sweden)

    Alfredo Reyes-Salazar

    2014-01-01

    Full Text Available The nonlinear seismic responses of 3D steel buildings with perimeter moment resisting frames (PMRF and interior gravity frames (IGF are studied explicitly considering the contribution of the IGF. The effect on the structural response of the stiffness of the beam-to-column connections of the IGF, which is usually neglected, is also studied. It is commonly believed that the flexibility of shear connections is negligible and that 2D models can be used to properly represent 3D real structures. The results of the study indicate, however, that the moments developed on columns of IGF can be considerable and that modeling buildings as plane frames may result in very conservative designs. The contribution of IGF to the lateral structural resistance may be significant. The contribution increases when their connections are assumed to be partially restrained (PR. The incremented participation of IGF when the stiffness of their connections is considered helps to counteract the no conservative effect that results in practice when lateral seismic loads are not considered in IGF while designing steel buildings with PMRF. Thus, if the structural system under consideration is used, the three-dimensional model should be used in seismic analysis and the IGF and the stiffness of their connections should be considered as part of the lateral resistance system.

  5. Seismic Response of 3D Steel Buildings considering the Effect of PR Connections and Gravity Frames

    Science.gov (United States)

    Haldar, Achintya; López-Barraza, Arturo; Rivera-Salas, J. Luz

    2014-01-01

    The nonlinear seismic responses of 3D steel buildings with perimeter moment resisting frames (PMRF) and interior gravity frames (IGF) are studied explicitly considering the contribution of the IGF. The effect on the structural response of the stiffness of the beam-to-column connections of the IGF, which is usually neglected, is also studied. It is commonly believed that the flexibility of shear connections is negligible and that 2D models can be used to properly represent 3D real structures. The results of the study indicate, however, that the moments developed on columns of IGF can be considerable and that modeling buildings as plane frames may result in very conservative designs. The contribution of IGF to the lateral structural resistance may be significant. The contribution increases when their connections are assumed to be partially restrained (PR). The incremented participation of IGF when the stiffness of their connections is considered helps to counteract the no conservative effect that results in practice when lateral seismic loads are not considered in IGF while designing steel buildings with PMRF. Thus, if the structural system under consideration is used, the three-dimensional model should be used in seismic analysis and the IGF and the stiffness of their connections should be considered as part of the lateral resistance system. PMID:24995357

  6. Soil-structure interaction effects in seismic analysis of turbine generator building on rock-like foundation

    International Nuclear Information System (INIS)

    Park, Chi Seon; Lee, Sang Hoon; Yoo, Kwang Hoon

    2004-01-01

    Soil properties supporting structure may become criteria determining methodologies for seismic response analysis of a structure. Regulatory Guide describes that a fixed-base assumption is acceptable for structures supported on rock or rock-like materials defined by a shear wave velocity of 3,500 ft/sec or greater at a shear strain of 10 -3 percent or smaller when considering preloaded soil conditions due to the structure. Seismic analyses for the Korean nuclear power plant (NPP) structures satisfying the above site soil condition have been completed through the fixed-base analysis. However, dynamic responses for relatively stiff structures such as NPP structures still have soil-structure interaction (SSI) effects. In other words, the fixed-base analysis does not always yield conservative results to be compared with SSI analysis. The SSI effects due to different stiff soil properties for Turbine Generator Building (TGB) structure to be constructed at Kori site of South Korea are investigated in views of floor response spectra (FRS) and member forces

  7. Effects of embedment including slip and separation on seismic SSI response of a nuclear reactor building

    International Nuclear Information System (INIS)

    Saxena, Navjeev; Paul, D.K.

    2012-01-01

    Highlights: ► Both the slip and separation of reactor base reduce with increase in embedment. ► The slip and separation become insignificant beyond 1/4 and 1/2 embedment respectively. ► The stresses in reactor reduce significantly upto 1/4 embedment. ► The stress reduction with embedment is more pronounced in case of tensile stresses. ► The modeling of interface is important beyond 1/8 embedment as stresses are underestimated otherwise. - Abstract: The seismic response of nuclear reactor containment building considering the effects of embedment, slip and separation at soil–structure interface requires modeling of the soil, structure and interface altogether. Slip and separation at the interface causes stress redistribution in the soil and the structure around the interface. The embedment changes the dynamic characteristics of the soil–structure system. Consideration of these aspects allows capturing the realistic response of the structure, which has been a research gap and presented here individually as well as taken together. Finite element analysis has been carried out in time domain to attempt the highly nonlinear problem. The study draws important conclusions useful for design of nuclear reactor containment building.

  8. Automated Detection of Buildings from Heterogeneous VHR Satellite Images for Rapid Response to Natural Disasters

    Directory of Open Access Journals (Sweden)

    Shaodan Li

    2017-11-01

    Full Text Available In this paper, we present a novel approach for automatically detecting buildings from multiple heterogeneous and uncalibrated very high-resolution (VHR satellite images for a rapid response to natural disasters. In the proposed method, a simple and efficient visual attention method is first used to extract built-up area candidates (BACs from each multispectral (MS satellite image. After this, morphological building indices (MBIs are extracted from all the masked panchromatic (PAN and MS images with BACs to characterize the structural features of buildings. Finally, buildings are automatically detected in a hierarchical probabilistic model by fusing the MBI and masked PAN images. The experimental results show that the proposed method is comparable to supervised classification methods in terms of recall, precision and F-value.

  9. Ambient Vibrations Measurements and 1D Site Response Modelling as a Tool for Soil and Building Properties Investigation

    Directory of Open Access Journals (Sweden)

    Sebastiano Imposa

    2018-03-01

    Full Text Available The safety of historic buildings heritage is an important task that becomes more substantial when the buildings are directed to educational purposes. The present study aims at evaluating the dynamic features of the Benedettini complex, an historic monastery located in downtown Catania, which is at present the headquarters of the humanistic studies department of the University of Catania. Both the building’s complex response to a seismic input and the soil-to-structure interaction were investigated using ambient noise recordings. The results point out a multiple dynamic behaviour of the monastery structure that shows several oscillation modes, whereas the identification of a single natural frequency can be observed in some sites where the structure can more freely oscillate. This observation is also confirmed by the variability of computed damping values that appear linked to the different rigidity of the structure, as a function of the either the longitudinal or transversal orientation of the investigated structural elements. Moreover, the comparison between the building’s fundamental period and spectral ratios frequencies, which were obtained from free field ambient noise measurements located outside the monastery, outline the presence of potential resonance effects between the site and structure during a seismic event. Numerical modelling of the local seismic response confirms the obtained experimental site frequencies, setting into evidence that higher amplification factors are reached in the same frequency range characterizing the building.

  10. A Distributed Intelligent Automated Demand Response Building Management System

    Energy Technology Data Exchange (ETDEWEB)

    Auslander, David [Univ. of California, Berkeley, CA (United States); Culler, David [Univ. of California, Berkeley, CA (United States); Wright, Paul [Univ. of California, Berkeley, CA (United States); Lu, Yan [Siemens Corporate Research Inc., Princeton, NJ (United States); Piette, Mary [Univ. of California, Berkeley, CA (United States)

    2013-03-31

    The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Response (openADR), Auto-­Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-­to-­building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov-­ March) and a steam absorption chiller for use in the warm months (April-­October). Lighting in the open office areas is provided by direct-­indirect luminaries with Building Management System-­based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load

  11. Seismic response of a nonsymmetric nuclear reactor building with a flexible stepped foundation

    International Nuclear Information System (INIS)

    Okano, H.; Sakai, A.; Takita, H.; Fukunishi, S.; Nakatogawa, T.; Kabayama, K.

    1993-01-01

    The effect of the non symmetry of a nuclear reactor building on its seismic response was studied. The nonsymmetric natures we considered, Included the eccentricity of the superstructure and the non symmetry of the cross section of the foundation. A three-dimensional analysis which employed Green's function was applied to study the interaction between the soil and the non symmetrically sectioned foundation. The effect of a flexible foundation on its seismic response was also studied by applying the sub structuring method, which combines the finite element method and Green's function method. (author)

  12. Nonlinear seismic response analysis of embedded reactor buildings based on the substructure approach in time domain

    International Nuclear Information System (INIS)

    Hasegawa, M.; Nakai, S.; Watanabe, T.

    1985-01-01

    A practical method for elasto-plastic seismic response analysis is described under considerations of nonlinear material law of a structure and dynamic soil-structure interaction. The method is essentially based on the substructure approach of time domain analysis. Verification of the present method is carried out for typical BWR-MARK II type reactor building which is embedded in a soil, and the results are compared with those of the frequency response analysis which gives good accuracy for linear system. As a result, the present method exhibits sufficient accuracy. Furthermore, elasto-plastic analyses considering the soil-structure interaction are made as an application of the present method, and nonlinear behaviors of the structure and embedment effects are discussed. (orig.)

  13. Structural wood products in onshore buildings at Naval Station Norfolk, 2000.

    Science.gov (United States)

    David B. McKeever

    2003-01-01

    As of December 31, 2000, there were 603 buildings at Naval Station (NAVSTA) Norfolk with a combined floor area of nearly 17.3 million ft2. In one-third of these buildings, structural wood products were used in one or more major structural building applications, utilizing an estimated 11.6 million board feet of lumber, 0.4 million ft2 (3/8-in. basis) of structural...

  14. Seismic soil–structure interaction analysis of a nuclear power plant building founded on soil and in degraded concrete stiffness condition

    International Nuclear Information System (INIS)

    Farahani, Reza V.; Dessalegn, Tewodros M.; Vaidya, Nishikant R.; Bazan-Zurita, Enrique

    2016-01-01

    Highlights: • Three dimensional finite element modeling of a Nuclear Power Plant (NPP) building founded on soil is described. • A simplified technique to consider degraded stiffness of concrete members in seismic analysis of NPP buildings is presented. • The effect of subsurface profiles on the seismic response of a NPP building is investigated. - Abstract: This study describes three-dimensional (3-D) finite element (FE) modeling and seismic Soil-Structure Interaction (SSI) analysis of a Nuclear Power Plant (NPP) Diesel Generator Building (DGB) that is founded on soil in degraded concrete stiffness condition. A new technique is presented that uses two horizontal and vertical FE models to consider the concrete stiffness reduction of NPP buildings subjected to orthogonal ground motion excitations, in which appropriate stiffness reduction factors, based on the input motion orientation, are applied. Seismic SSI analysis is performed for each model separately, and dynamic responses are calculated in the three global directions. The results of the analysis for the two FE models are then combined, using the square-root-of-the-sum-of-squares (SRSS) combination rule. A sensitivity analysis is also performed to investigate the subsurface profile effect on the In-Structure (acceleration) Response Spectra (ISRS) of the building when subjected to site-specific Foundation Input Response Spectra (FIRS) that exhibit high spectral amplifications in the high-frequency range. The sensitivity analysis considers three strain-compatible subsurface profiles that represent Lower-Bound (LB), Best-Estimate (BE), and Upper-Bound (UB) conditions at the DGB site. The sensitivity analysis results indicate that the seismic response of the DGB founded on soil highly depends on the subsurface profile; i.e., each of the LB, BE, and UB subsurface profiles can maximize building seismic response when subjected to FIRS that exhibit high spectral amplifications in the high-frequency range

  15. Constructive systems, load-bearing and enclosing structures of high-rise buildings

    Science.gov (United States)

    Anatol'evna Korol', Elena; Olegovna Kustikova, Yuliya

    2018-03-01

    As the height of the building increases, loads on load-carrying structures increase dramatically, and as a result of the development of high-rise construction, several structural systems of such buildings have been developed: frame, frame-frame, cross-wall, barrel, box-type, box-to-wall ("pipe in pipe", "Trumpet in the farm"), etc. In turn, the barrel systems have their own versions: cantilever support of the ceilings on the trunk, suspension of the outer part of the overlap to the upper carrying console "hanging house" or its support by means of the walls on the lower bearing cantilever, intermediate position of the supporting cantilevers in height to the floor, from a part of floors. The object of the study are the structural solutions of high-rise buildings. The subject of the study is the layout of structural schemes of high-rise buildings, taking into account the main parameters - altitude (height), natural climatic conditions of construction, materials of structural elements and their physical and mechanical characteristics. The purpose of the study is to identify the features and systematization of structural systems of high-rise buildings and the corresponding structural elements. The results of the research make it possible, at the stage of making design decisions, to establish rational parameters for the correspondence between the structural systems of high-rise buildings and their individual elements.

  16. Ethical Guidelines for Structural Interventions to Small-Scale Historic Stone Masonry Buildings.

    Science.gov (United States)

    Hurol, Yonca; Yüceer, Hülya; Başarır, Hacer

    2015-12-01

    Structural interventions to historic stone masonry buildings require that both structural and heritage values be considered simultaneously. The absence of one of these value systems in implementation can be regarded as an unethical professional action. The research objective of this article is to prepare a guideline for ensuring ethical structural interventions to small-scale stone historic masonry buildings in the conservation areas of Northern Cyprus. The methodology covers an analysis of internationally accepted conservation documents and national laws related to the conservation of historic buildings, an analysis of building codes, especially Turkish building codes, which have been used in Northern Cyprus, and an analysis of the structural interventions introduced to a significant historic building in a semi-intact state in the walled city of Famagusta. This guideline covers issues related to whether buildings are intact or ruined, the presence of earthquake risk, the types of structural decisions in an architectural conservation project, and the values to consider during the decision making phase.

  17. The effects of soil-structure interaction modeling techniques on in-structure response spectra

    International Nuclear Information System (INIS)

    Johnson, J.J.; Wesley, D.A.; Almajan, I.T.

    1977-01-01

    The structure considered for this investigation consisted of the reactor containment building (RCB) and prestressed concrete reactor vessel (PCRV) for a HTGR plant. A conventional lumped-mass dynamic model in three dimensions was used in the study. The horizontal and vertical response, which are uncoupled due to the symmetry of the structure, were determined for horizontal and vertical excitation. Five different site conditions ranging from competent rock to a soft soil site were considered. The simplified approach to the overall plant analysis utilized stiffness proportional composite damping with a limited amount of soil damping consistent with US NRC regulatory guidelines. Selected cases were also analyzed assuming a soil damping value approximating the theoretical value. The results from the simplified approach were compared to those determined by rigorously coupling the structure to a frequency independent half-space representation of the soil. Finally, equivalent modal damping ratios were found by matching the frequency response at a point within the coupled soil-structure system determined by solution of the coupled and uncoupled equations of motion. The basis for comparison of the aforementioned techniques was the response spectra at selected locations within the soil-structure system. Each of the five site conditions was analyzed and in-structure response spectra were generated. The response spectra were combined to form a design envelope which encompasses the entire range of site parameters. Both the design envelopes and the site-by-site results were compared

  18. Effect of the flexibility of the base mat on seismic response of a PWR-reactor building

    International Nuclear Information System (INIS)

    Waas, G.; Riggs, H.R.

    1983-01-01

    The flexibility of the base mat influences the stiffness and the radiation damping of foundations, In this paper its effect on the seismic response of an axisymmetric PWR-reactor building is investigated. The base mat of the building is stiffened by cylindrical concrete walls and by a rigid block in the center. Soft and stiff soil conditions are considered. The structure and its foundation are modelled by axisymmetric shell and volume elements with Fourier expansions in the circumferential direction. The soil is treated as a horizontally layered viscoelastic medium. Soil and structure are coupled along nodal rings. The stiffness matrix of the soil is computed using an explicit semi-analytic solution for displacements caused by ring loads acting on the surface or within a layered medium. The analysis is performed in the frequency domain, and the response in the time domain is computed by the fast Fourier transformation. The earthquake response is computed with and without including the flexibility of the relatively stiff base mat. The comparison shows that including the flexibility of the mat has hardly any effect on the resonant frequencies and the damping of the fundamental rocking and vertical modes. This is the case for soft and stiff soil conditions. However, the flexibility of the mat strongly affects the first structural deformation mode, in which the external and internal structures deflect in opposite directions. (orig./HP)

  19. Evaluation of the Reduction of Seismic Response of Adjacent Structures Using Viscous Damper Joint

    Directory of Open Access Journals (Sweden)

    Hamed Karbalay Malek

    2017-09-01

    Full Text Available This study examines the effect of common viscose damper on the behavior of adjacent reinforced concrete structures. For this purpose, three reinforced concrete 3, 5 and 7 floors buildings with a regular plan were selected and were compared in two cases without and with viscous dampers at the seams. They are designed based on discussions of Buildings Regulations 2800 and the 6 and 9 issues of Iranian National Building Regulations. Those buildings face under accelerograms of Bam, Mangil and El Centro, and then they are analyzed with nonlinear modal time history. This Accelerograms before applying to the structures, they are scaled based on the 2800 Regulations. Those buildings were modeled by SAP2000 finite element modeling software. Linear behavior of structural components of the structure and the non-linear behavior viscous damper were modeled. Finally, the seismic response of buildings includes the base shear force, up to a maximum lateral acceleration of seismic classes and classes for both with and without the viscous damper have been extracted and compared. The results showed the reduction in relative lateral displacement, maximum acceleration and base cut applied to structure in the presence of viscous dampers between two structures. This decline is not even in the direction that the viscous damper is viewed as significant.

  20. Adoption of Smart Structures for Prevention of Health Hazards in Buildings

    Science.gov (United States)

    Oke, Ayodeji; Aigbavboa, Clinton; Ngema, Wiseman

    2017-11-01

    The importance of building quality to the health and well-being of occupants and surrounding neighbors cannot be overemphasized. Smart structures were construed to proffer solution to various issues of sustainable development including social factors that is concerned with health and safety of people. Based on existing literature materials on building quality, smart structures and general aspect of sustainable developments, this study examined the benefits of smart structures in the prevention of various health issues in infrastructural buildings, which has been a concern for stakeholders in the architecture, engineering and construction industry. The criterion for indoor environmental quality was adopted and various health and bodily issues related to building quality were explained. The adoption of smart structure concept will help to manage physical, chemical, biological and psychological factors of building with a view to enhancing better quality of life of occupants.

  1. Modelling of internal structure in seismic analysis of a PHWR building

    International Nuclear Information System (INIS)

    Reddy, G.R.; Vaze, K.K.; Kushawaha, H.S.; Ingle, R.K.; Subramanian, K.V.

    1991-01-01

    Seismic analysis of complex and large structures, consisting of thick shear walls, such as Reactor Building is very involved and time consuming. It is a standard practice to model the structure as a stick model to predict reasonably the dynamic behaviour of the structure. It is required to determine approximate equivalent sectional properties of Internal Structure for representation in the stick model. The restraint to warping can change the stress distribution thus affecting the centre of rigidity and torsional inertia, Hence, standard formulae does not hold good for determination of sectional properties of the Internal Structure. In this case the equivalent sectional properties for the Internal Structure are calculated using a Finite Element Model (FEM) of the Internal Structure and applying unit horizontal forces in each direction. A 3-D stick model is developed using the guidelines. Using the properties calculated by FEM and also by standard formulae, the responses of the 3-D stick model are compared. (J.P.N.)

  2. Contaminant deposition building shielding factors for US residential structures.

    Science.gov (United States)

    Dickson, Elijah; Hamby, David; Eckerman, Keith

    2017-10-10

    This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario from contaminant deposition on the roof and surrounding surfaces. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations from contaminant deposition on the roof and surrounding ground as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement as well for single-wide manufactured housing-unit. © 2017 IOP Publishing Ltd.

  3. Contaminant deposition building shielding factors for US residential structures

    International Nuclear Information System (INIS)

    Dickson, E D; Hamby, D M; Eckerman, K F

    2015-01-01

    This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario from contaminant deposition on the roof and surrounding surfaces. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations from contaminant deposition on the roof and surrounding ground as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement as well for single-wide manufactured housing-unit. (paper)

  4. Cloud immersion building shielding factors for US residential structures

    International Nuclear Information System (INIS)

    Dickson, E D; Hamby, D M

    2014-01-01

    This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario within a semi-infinite cloud of radioactive material. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement, as well for single-wide manufactured housing-units. (paper)

  5. Deployable bamboo structure project: A building life-cycle report

    Science.gov (United States)

    Firdaus, Adrian; Prastyatama, Budianastas; Sagara, Altho; Wirabuana, Revian N.

    2017-11-01

    Bamboo is considered as a sustainable material in the world of construction, and it is vastly available in Indonesia. The general utilization of the material is increasingly frequent, however, its usage as a deployable structure-a recently-developed use of bamboo, is still untapped. This paper presents a report on a deployable bamboo structure project, covering the entire building life-cycle phase. The cycle encompasses the designing; fabrication; transportation; construction; operation and maintenance; as well as a plan for future re-use. The building is made of a configuration of the structural module, each being a folding set of bars which could be reduced in size to fit into vehicles for easy transportation. Each structural module was made of Gigantochloa apus bamboo. The fabrication, transportation, and construction phase require by a minimum of three workers. The fabrication and construction phase require three hours and fifteen minutes respectively. The building is utilized as cafeteria stands, the operation and maintenance phase started since early March 2017. The maintenance plan is scheduled on a monthly basis, focusing on the inspection of the locking mechanism element and the entire structural integrity. The building is designed to allow disassembly process so that it is reusable in the future.

  6. Seismic response of base-isolated buildings using a viscoelastic model

    International Nuclear Information System (INIS)

    Uras, R.A.

    1993-01-01

    Due to recent developments in elastomer technology,seismic isolation using elastomer bearings is rapidly gaining acceptance as a design tool to enhance structural seismic margins and to protect people and equipment from earthquake damage. With proper design of isolators, the fundamental frequency of the structure can be reduced to a value that is lower than the dominant frequencies of earthquake ground motions. The other feature of an isolation system is that it can provide a mechanism for energy dissipation. In the USA, the use of seismic base-isolation has become an alternate strategy for advanced Liquid Metal-cooled Reactors (LMRs). ANL has been deeply involved in the development and implementation of seismic isolation for use in both nuclear facilities and civil structures for the past decade. Shimizu Corporation of Japan has a test facility at Tohoku University in Sendai, Japan. The test facility has two buildings: one is base isolated and the other is conventionally founded. The buildings are full-size, three-story reinforced concrete structures. The dimensions and construction of the superstructures are identical. They were built side by side in a seismically active area. In 1988, the ANL/Shimizu Joint Program was established to study the differences in behavior of base-isolated and ordinarily founded structures when subjected to earthquake loading. A more comprehensive description of this joint program is presented in a companion paper (Wang et al. 1993). With the increased use of elastomeric polymers in industrial applications such as isolation bearings, the importance of constitutive modeling of viscoelastic materials is more and more pronounced. A realistic representation of material behavior is essential for computer simulations to replicate the response observed in experiments

  7. Structural response of nuclear containment shield buildings with unanticipated construction openings

    Science.gov (United States)

    Mac Namara, Sinead Caitriona

    As Nuclear Power Plants age many require steam generator replacement. There is a nickel alloy in the steam generator tubes that is susceptible to stress cracking and although these cracks can be sealed the generator becomes uneconomical without 10%-15% of the tubes. The steam generator in a typical nuclear power plant is housed in the containment structure next to the reactor. The equipment hatch is not big enough to facilitate steam generator replacement, thus construction openings in the dome of the containment structure are required. To date the structural consequences of construction openings in the dome have not been examined. This thesis examines the effects of such openings. The prototype concrete dome is made up of a 2 ft thick dome atop 3 ft thick and 170 ft high cylindrical walls (radius 65.5 ft) with a tension ring 15 ft high and 8 ft thick in between. The dome of the building is cast in two layers; a lower 9 inch layer that serves as the formwork for an upper 15 inch layer. The weight of the dome is carried in axial compression along the hoops and meridians of the dome. The first finite element model uses shell elements and considers two limiting load cases; where the two layers act as one, and where the lower layer carries the weight of both. The openings interrupt the hoops and meridians and the weight of the dome must be redistributed around the openings. Without openings, the stresses due to dead load in the structure are very low when compared to the material strength. The impact of the openings is increased compression stresses near the opening. The maximum stresses are approximately four times larger than in the original structure. These results are confirmed by the second model which is made from layers of solid elements. This model shows a significant difference between the compression on the top surface of the dome, in the affected areas, and that on the bottom surface, leading to shear stresses. These shear stresses are largest around the

  8. Building with electromagnetic shield structure for individual floors

    International Nuclear Information System (INIS)

    Takahashi, T.; Nakamura, M.; Yabana, Y.; Ishikawa, T.; Nagata, K.

    1991-01-01

    This invention relates to a building having a floor-by-floor electromagnetic shield structure well-suited for application to an information network system in which an electromagnetically shielded space is divided by individual floors and electric waves are utilized within the building on a floor-by-floor basis. (author). 8 figs

  9. Building with electromagnetic shield structure for individual floors

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, T; Nakamura, M; Yabana, Y; Ishikawa, T; Nagata, K

    1991-09-10

    This invention relates to a building having a floor-by-floor electromagnetic shield structure well-suited for application to an information network system in which an electromagnetically shielded space is divided by individual floors and electric waves are utilized within the building on a floor-by-floor basis. (author). 8 figs.

  10. Comparison of seismic response of ordinary and base-isolated structures

    International Nuclear Information System (INIS)

    Kuroda, T.; Kobatake, M.; Seidensticker, R.W.; Chang, Y.W.

    1992-01-01

    Seismic isolation is growing rapidly worldwide as a cost-effective and reliable design strategy for a wide range of critical and important facilities (e.g., hospitals, computer centers, etc.) Shimizu Corporation of Japan has a test facility at Tohoku University in Sendai, Japan. The test facility was constructed in 1986 and has two buildings: one is base isolated and the other is conventionally founded. The buildings are full-size, three-story reinforced concrete structures. The dimensions and construction of the superstructures are identical. For the past several years, Shimizu Corporation has installed a number of different isolation systems in the isolated building at the test facility to study the response of base isolation systems to actual earthquake motions. Argonne National Laboratory (ANL) has been deeply involved in the development of seismic isolation for use in nuclear facilities for the past decade. Using the funding and direction of the US Department of Energy (USDOE), ANL has been developing methodology needed to evaluate the usefulness and effectiveness of seismic isolation for advanced liquid metal-cooled reactors (LMRs). This paper compares the seismic responses of ordinary and base-isolated buildings. Earthquake records of significant importance from April 1989 to September 1991, after the installation of bearings have been analyzed. Numerical simulations of the building responses have been performed and correlated with earthquake observation data. It is hoped that the results of this study will provide guidelines for the future use of isolator bearings for mitigation of earthquake damages

  11. Probabilistic Assessment of Structural Seismic Damage for Buildings in Mid-America

    International Nuclear Information System (INIS)

    Bai, Jong-Wha; Hueste, Mary Beth D.; Gardoni, Paolo

    2008-01-01

    This paper provides an approach to conduct a probabilistic assessment of structural damage due to seismic events with an application to typical building structures in Mid-America. The developed methodology includes modified damage state classifications based on the ATC-13 and ATC-38 damage states and the ATC-38 database of building damage. Damage factors are assigned to each damage state to quantify structural damage as a percentage of structural replacement cost. To account for the inherent uncertainties, these factors are expressed as random variables with a Beta distribution. A set of fragility curves, quantifying the structural vulnerability of a building, is mapped onto the developed methodology to determine the expected structural damage. The total structural damage factor for a given seismic intensity is then calculated using a probabilistic approach. Prediction and confidence bands are also constructed to account for the prevailing uncertainties. The expected seismic structural damage is assessed for a typical building structure in the Mid-America region using the developed methodology. The developed methodology provides a transparent procedure, where the structural damage factors can be updated as additional seismic damage data becomes available

  12. Regional Design Approach in Designing Climatic Responsive Administrative Building in the 21st Century

    Science.gov (United States)

    Haja Bava Mohidin, Hazrina Binti; Ismail, Alice Sabrina

    2015-01-01

    The objective of this paper is to explicate on the study of modern administrative building in Malaysia which portrays regional design approach that conforms to the local context and climate by reviewing two case studies; Perdana Putra (1999) and former Prime Minister's Office (1967). This paper is significant because the country's stature and political statement was symbolized by administrative building as a national icon. In other words, it is also viewed as a cultural object that is closely tied to a particular social context and nation historical moment. Administrative building, therefore, may exhibit various meanings. This paper uses structuralism paradigm and semiotic principles as a methodological approach. This paper is of importance for practicing architects and society in the future as it offers new knowledge and understanding in identifying the suitable climatic consideration that may reflect regionalist design approach in modern administrative building. These elements then may be adopted in designing public buildings in the future with regional values that are important for expressing national culture to symbolize the identity of place and society as well as responsive to climate change.

  13. 3-dimensional earthquake response analysis of embedded reactor building using hybrid model of boundary elements and finite elements

    International Nuclear Information System (INIS)

    Muto, K.; Motosaka, M.; Kamata, M.; Masuda, K.; Urao, K.; Mameda, T.

    1985-01-01

    In order to investigate the 3-dimensional earthquake response characteristics of an embedded structure with consideration for soil-structure interaction, the authors have developed an analytical method using 3-dimensional hybrid model of boundary elements (BEM) and finite elements (FEM) and have conducted a dynamic analysis of an actual nuclear reactor building. This paper describes a comparative study between two different embedment depths in soil as elastic half-space. As the results, it was found that the earthquake response intensity decreases with the increase of the embedment depth and that this method was confirmed to be effective for investigating the 3-D response characteristics of embedded structures such as deflection pattern of each floor level, floor response spectra in high frequency range. (orig.)

  14. Effect of structural design on traffic-induced building vibrations

    DEFF Research Database (Denmark)

    Persson, Peter; Andersen, Lars Vabbersgaard; Persson, Kent

    2017-01-01

    Population growth and urbanization results in densified cities, where new buildings are being built closer to existing vibration sources such as road-, tram- and rail traffic. In addition, new transportation systems are constructed closer to existing buildings. Potential disturbing vibrations...... are one issue to consider in planning urban environment and densification of cities. Vibrations can be disturbing for humans but also for sensitive equipment in, for example, hospitals. In determining the risk for disturbing vibrations, the distance between the source and the receiver, the ground...... properties, and type and size of the building are governing factors. In the paper, a study is presented aiming at investigating the influence of various parameters of the building's structural design on vibration levels in the structure caused by ground surface loads, e.g. traffic. Parameters studied...

  15. Evaluation of fault-normal/fault-parallel directions rotated ground motions for response history analysis of an instrumented six-story building

    Science.gov (United States)

    Kalkan, Erol; Kwong, Neal S.

    2012-01-01

    According to regulatory building codes in United States (for example, 2010 California Building Code), at least two horizontal ground-motion components are required for three-dimensional (3D) response history analysis (RHA) of buildings. For sites within 5 km of an active fault, these records should be rotated to fault-normal/fault-parallel (FN/FP) directions, and two RHA analyses should be performed separately (when FN and then FP are aligned with the transverse direction of the structural axes). It is assumed that this approach will lead to two sets of responses that envelope the range of possible responses over all nonredundant rotation angles. This assumption is examined here using a 3D computer model of a six-story reinforced-concrete instrumented building subjected to an ensemble of bidirectional near-fault ground motions. Peak responses of engineering demand parameters (EDPs) were obtained for rotation angles ranging from 0° through 180° for evaluating the FN/FP directions. It is demonstrated that rotating ground motions to FN/FP directions (1) does not always lead to the maximum responses over all angles, (2) does not always envelope the range of possible responses, and (3) does not provide maximum responses for all EDPs simultaneously even if it provides a maximum response for a specific EDP.

  16. A seismic design of nuclear reactor building structures applying seismic isolation system in a seismicity region-a feasibility case study in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Tetsuo [The University of Tokyo, Tokyo (Japan); Yamamoto, Tomofumi; Sato, Kunihiko [Mitsubishi Heavy Industries, Ltd., Kobe (Japan); Jimbo, Masakazu [Toshiba Corporation, Yokohama (Japan); Imaoka, Tetsuo [Hitachi-GE Nuclear Energy, Ltd., Hitachi (Japan); Umeki, Yoshito [Chubu Electric Power Co. Inc., Nagoya (Japan)

    2014-10-15

    A feasibility study on the seismic design of nuclear reactor buildings with application of a seismic isolation system is introduced. After the Hyogo-ken Nanbu earthquake in Japan of 1995, seismic isolation technologies have been widely employed for commercial buildings. Having become a mature technology, seismic isolation systems can be applied to NPP facilities in areas of high seismicity. Two reactor buildings are discussed, representing the PWR and BWR buildings in Japan, and the application of seismic isolation systems is discussed. The isolation system employing rubber bearings with a lead plug positioned (LRB) is examined. Through a series of seismic response analyses using the so-named standard design earthquake motions covering the design basis earthquake motions obtained for NPP sites in Japan, the responses of the seismic isolated reactor buildings are evaluated. It is revealed that for the building structures examined herein: (1) the responses of both isolated buildings and isolating LRBs fulfill the specified design criteria; (2) the responses obtained for the isolating LRBs first reach the ultimate condition when intensity of motion is 2.0 to 2.5 times as large as that of the design-basis; and (3) the responses of isolated reactor building fall below the range of the prescribed criteria.

  17. TLCD Parametric Optimization for the Vibration Control of Building Structures Based on Linear Matrix Inequality

    OpenAIRE

    Huo, Linsheng; Qu, Chunxu; Li, Hongnan

    2014-01-01

    Passive liquid dampers have been used to effectively reduce the dynamic response of civil infrastructures subjected to earthquakes or strong winds. The design of liquid dampers for structural vibration control involves the determination of the optimal parameters. This paper presents an optimal design methodology for tuned liquid column dampers (TLCDs) based on the H∞ control theory. A practical structure, Dalian Xinghai Financial Business Building, is used to illustrate the feasibility of the...

  18. Decentralized Networked Control of Building Structures

    Czech Academy of Sciences Publication Activity Database

    Bakule, Lubomír; Rehák, Branislav; Papík, Martin

    2016-01-01

    Roč. 31, č. 11 (2016), s. 871-886 ISSN 1093-9687 R&D Projects: GA ČR GA13-02149S Institutional support: RVO:67985556 Keywords : decentralized control * networked control * building structures Subject RIV: BC - Control Systems Theory Impact factor: 5.786, year: 2016

  19. Synthesis of vibration control and health monitoring of building structures under unknown excitation

    International Nuclear Information System (INIS)

    He, Jia; Huang, Qin; Xu, You-Lin

    2014-01-01

    The vibration control and health monitoring of building structures have been actively investigated in recent years but often treated separately according to the primary objective pursued. In this study, a time-domain integrated vibration control and health monitoring approach is proposed based on the extended Kalman filter (EKF) for identifying the physical parameters of the controlled building structures without the knowledge of the external excitation. The physical parameters and state vectors of the building structure are then estimated and used for the determination of the control force for the purpose of the vibration attenuation. The interaction between the health monitoring and vibration control is revealed and assessed. The feasibility and reliability of the proposed approach is numerically demonstrated via a five-story shear building structure equipped with magneto-rheological (MR) dampers. Two types of excitations are considered: (1) the EI-Centro ground excitation underneath of the building and (2) a swept-frequency excitation applied on the top floor of the building. Results show that the structural parameters as well as the unknown dynamic loadings could be identified accurately; and, at the same time, the structural vibration is significantly reduced in the building structure. (paper)

  20. KEY ASPECTS OF ENSURING ENERGY EFFICIENCY OF BUILDINGS AND STRUCTURES

    Directory of Open Access Journals (Sweden)

    S.G. Abramyan

    2017-06-01

    Full Text Available The paper is based on the review of the foreign and national academic literature and intended to emphasize the issues of ensuring energy efficiency of buildings and structures applicable to all the countries as for reconstruction of existing buildings as for erection of new ones . The author highlights the key aspects of the provision of energy efficiency of buildings and structures in some foreign countries. The conclusion is made that the studies are mainly aimed at discovering new heat insulation materials, whereby polystyrene insulation is found to be the most widespread wall insulation material in a number of countries. At the same time, it is observed that the ongoing research is focused on solutions to optimize the structure of walling systems in terms of both insulant thickness and the number and sequence of insulation layers in the walling structure. A conclusion is made that hyper insulation of external walls leads to considerable expenses arising due to cooling during the summer season. The use of prefabricated vacuum panels as a heat insulation layer and off-the-shelf single-layer structures, subject to their heat insulation characteristics, appears a more constructive way to meet the energy efficiency requirements, as the arrangement of ideal air space in multilayered walls proves a significant challenge today. One of the most promising ways to ensure energy efficiency is the use of multifunctional polyvalent walls and provision of polyvalent heat supply from renewable energy sources. Since energy efficiency depends on the spatial arrangement of buildings, construction must ensure a minimum ratio of the area of enclosing structures to the overall building volume (by adding on new facilities in case of reconstruction. It is noted that a systemic approach to ensuring energy efficiency of buildings is impossible without proper regard to the environmental parameters of heat insulation materials.

  1. Noise, buildings and people

    Energy Technology Data Exchange (ETDEWEB)

    Croome, D J

    1977-01-01

    This book covers the physics of acoustics necessary to understand the analytical aspects of acoustical design and noise control in buildings. The major part is devoted to the problems of noise and man, and other chapters cover features of noise control in and around buildings. In an introduction, building environmental engineering is dealth with in general terms of architecture, creativity, systms design, etc. Aspects of the acoustical environment, noise sources in buildings, control of airborne and structure-borne noise and acoustical design techniques are covered in Part II. Items include: comfort, physiological response to noise and vibrations, noise criteria, human performance, speech communication, landscaped offices, sound generation by air-conditioning and heating equipment, building structure and noise attenuation, acoustical design. Part III gives some fundamentals of acoustics; mechanical vibration, wave motion, propagation of sound, structure-borne sound, behavior of sound in rooms, transmission of sound through structure. References include lists of British standards and booklets on health and safety at work.

  2. Seismic isolation structure for pool-type LMFBR - isolation building with vertically isolated floor for NSSS

    International Nuclear Information System (INIS)

    Sakurai, A.; Shiojiri, H.; Aoyagi, S.; Matsuda, T.; Fujimoto, S.; Sasaki, Y.; Hirayama, H.

    1987-01-01

    The NSSS isolation floor vibration characteristics were made clear. Especially, the side support bearing (rubber bearing) is effective for horizontal floor motion restraint and rocking motion control. Seismic isolation effects for responses of the reactor components can be sufficiently expected, using the vertical seismic isolation floor. From the analytical and experimental studies, the following has been concluded: (1) Seismic isolation structure, which is suitable for large pool-type LMFBR, were proposed. (2) Seismic response characteristics of the seismic isolation structure were investigated. It was made clear that the proposed seismic isolation (Combination of the isolated building and the isolated NSSS floor) was effective. (orig./HP)

  3. Realization of a demand response in office-buildings; Umsetzung eines Lastmangements in Buerogebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Jungwirth, Johannes; Berger, Christian [TU Muenchen (Germany). Lehrstuhl fuer Energiewirtschaft und Anwendungstechnik; Roessel, Timm [TU Muenchen (Germany). Lehrstuhl fuer Bauklimatik und Haustechnik

    2011-07-01

    Due to the mostly fluctuating feed-in characteristics, the strong expansion of renewable energy producers lets expect a paradigm shift in the structure of the power supply concept. The integration of renewables into the electricity grid requires new ways to compensate the temporal discrepancy between production and consumption. Such a load management or demand response requires electrical devices that can be varied with time in their mode of operation. The results of a feasibility study show that amongst other things a lot of electric devices being suitable for the implementation of the load management are present in office buildings and administration buildings. As an already existing communication structure one may refer to the equipment automation for the control of the individual devices. In order to realize the existing potentials, an innovative control strategy based on the existing hardware is necessary. This control strategy may adapt the mode of operation to an external signal. In order to allow a realistic development of such control strategies, a hardware-in-the-loop (HIL) testing environment was created which allows a development of control strategies by means of a real building automation controller under defined and reproducible conditions without adverse effects on the users of a building. The controller is connected to a personal computer which models the building and systems engineering taking into account the user behaviour in real time. All gates of the building automation are tapped and provided as input data to the simulation. Based on this information, in the simulation the reaction of the building is calculated for each time step. The current spatial conditions are reported back to the building automation. Thus, the controller can be tested with all the functionality in the HIL environment. Any locations and environmental conditions in the development process can be compared and evaluated by means of the simulation. The goal is to develop an

  4. Assessment of dynamic and long-term performance of an innovative multi-story timber building via structural monitoring and dynamic testing

    Science.gov (United States)

    Omenzetter, Piotr; Morris, Hugh; Worth, Margaret; Gaul, Andrew; Jager, Simon; Desgeorges, Yohann

    2012-04-01

    An innovative three-story timber building, using self-centering, post-tensioned timber shear walls as the main horizontal load resisting system and lightweight non-composite timber-concrete floors, has recently been completed in Nelson, New Zealand. It is expected to be the trailblazer for similar but taller structures to be more widely adopted. Performance based standards require an advanced understanding of building responses and in order to meet the need for in-situ performance data the building has been subjected to forced vibration testing and instrumented for continuous monitoring using a total of approximately 90 data channels to capture its dynamic and long-term responses. The first part of the paper presents a brief discussion of the existing research on the seismic performance of timber frame buildings and footfall induced floor vibrations. An outline of the building structural system, focusing on the novel design solutions, is then discussed. This is followed by the description of the monitoring system. The analysis of monitoring results starts with a discussion of the monitoring of long-term deformations. Next, the assessment of the floor vibration serviceability performance is outlined. Then, the forced vibration tests conducted on the whole building at different construction stages are reviewed. The system identification results from seismic shaking records are also discussed. Finally, updating of a finite element model of the building is conducted.

  5. AP1000 Shield Building Dynamic Response for Different Water Levels of PCCWST Subjected to Seismic Loading considering FSI

    Directory of Open Access Journals (Sweden)

    Daogang Lu

    2015-01-01

    Full Text Available Huge water storage tank on the top of many buildings may affect the safety of the structure caused by fluid-structure interaction (FSI under the earthquake. AP1000 passive containment cooling system water storage tank (PCCWST placed at the top of shield building is a key component to ensure the safety of nuclear facilities. Under seismic loading, water will impact the wall of PCCWST, which may pose a threat to the integrity of the shield building. In the present study, an FE model of AP1000 shield building is built for the modal and transient seismic analysis considering the FSI. Six different water levels in PCCWST were discussed by comparing the modal frequency, seismic acceleration response, and von Mises stress distribution. The results show the maximum von Mises stress emerges at the joint of shield building roof and water around the air inlet. However, the maximum von Mises stress is below the yield strength of reinforced concrete. The results may provide a reference for design of the AP1000 and CAP1400 in the future.

  6. Evaluation of the dynamic responses of high rise buildings with respect to the direct methods for soil-foundation-structure interaction effects and comparison with the approximate methods

    Directory of Open Access Journals (Sweden)

    Jahangir Khazaei

    2017-08-01

    Full Text Available In dynamic analysis, modeling of soil medium is ignored because of the infinity and complexity of the soil behavior and so the important effects of these terms are neglected, while the behavior of the soil under the structure plays an important role in the response of the structure during an earthquake. In fact, the soil layers and soil foundation structure interaction phenomena can increase the applied seismic forces during earthquakes that has been examined with different methods. In this paper, effects of soil foundation structure interaction on a steel high rise building has been modeled using Abaqus software for nonlinear dynamic analysis with finite element direct method and simulation of infinite boundary condition for soil medium and also approximate Cone model. In the direct method, soil, structure and foundation are modeled altogether. In other hand, for using Cone model as a simple model, dynamic stiffness coefficients have been employed to simulate soil with considering springs and dashpots in all degree of freedom. The results show that considering soil foundation structure interaction cause increase in maximum lateral displacement of structure and the friction coefficient of soil-foundation interface can alter the responses of structure. It was also observed that the results of the approximate methods have good agreement for engineering demands.

  7. The fundamentals of structural building codes

    NARCIS (Netherlands)

    Vrouwenvelder, A.C.W.M.

    2001-01-01

    Partial Factor Design is nowadays a generally accepted design method for building and civil engineering structures. For most engineers the general philosophy that the safety factors depend on the type of the load and on the limit state under consideration makes sense. However, the background, in

  8. Recorded earthquake responses from the integrated seismic monitoring network of the Atwood Building, Anchorage, Alaska

    Science.gov (United States)

    Celebi, M.

    2006-01-01

    An integrated seismic monitoring system with a total of 53 channels of accelerometers is now operating in and at the nearby free-field site of the 20-story steel-framed Atwood Building in highly seismic Anchorage, Alaska. The building has a single-story basement and a reinforced concrete foundation without piles. The monitoring system comprises a 32-channel structural array and a 21-channel site array. Accelerometers are deployed on 10 levels of the building to assess translational, torsional, and rocking motions, interstory drift (displacement) between selected pairs of adjacent floors, and average drift between floors. The site array, located approximately a city block from the building, comprises seven triaxial accelerometers, one at the surface and six in boreholes ranging in depths from 15 to 200 feet (???5-60 meters). The arrays have already recorded low-amplitude shaking responses of the building and the site caused by numerous earthquakes at distances ranging from tens to a couple of hundred kilometers. Data from an earthquake that occurred 186 km away traces the propagation of waves from the deepest borehole to the roof of the building in approximately 0.5 seconds. Fundamental structural frequencies [0.58 Hz (NS) and 0.47 Hz (EW)], low damping percentages (2-4%), mode coupling, and beating effects are identified. The fundamental site frequency at approximately 1.5 Hz is close to the second modal frequencies (1.83 Hz NS and 1.43 EW) of the building, which may cause resonance of the building. Additional earthquakes prove repeatability of these characteristics; however, stronger shaking may alter these conclusions. ?? 2006, Earthquake Engineering Research Institute.

  9. Assessment of Technogenic Accident Risk of Industrial Building Structures

    Science.gov (United States)

    Baiburin, D. A.; Baiburin, A. Kh

    2017-11-01

    A methodology for assessing the risk of an industrial building accident was developed taking into account the damage caused by various localization of collapse. Before the beginning of the survey of a facility technical condition, groups including the same type of building structures are selected. Further, assessment is made for the reduction in their load-carrying capacity from the strength and stability conditions taking into account defects. The characteristics of the influence of defects and structural damage on a building safety is the degree of compliance with the standards expressed by the reliability level. Reliability levels assignment is carried out on the basis of calculations, operating experience and inspection of a particular type of structure according to the formalized rules. The risk of collapse according to a separate scenario is calculated for structures that are capable and incapable of causing a progressive ossification. The results of the technique application are based on the analysis of the accident risk at the welding shop “Vysota (Height) 239” of the Chelyabinsk Pipe Rolling Plant.

  10. On Directionality of Phrase Structure Building

    Science.gov (United States)

    Chesi, Cristiano

    2015-01-01

    Minimalism in grammatical theorizing (Chomsky in "The minimalist program." MIT Press, Cambridge, 1995) led to simpler linguistic devices and a better focalization of the core properties of the structure building engine: a lexicon and a free (recursive) phrase formation operation, dubbed Merge, are the basic components that serve in…

  11. Seismic safety of building structures of NPP Kozloduy III

    International Nuclear Information System (INIS)

    Varbanov, G.I.; Kostov, M.K.; Stefanov, D.D.; Kaneva, A.D.

    2005-01-01

    In the proposed paper is presented a general summary of the analyses carried out to evaluate the dynamic behavior and to assess the seismic safety of some safety related building structures of NPP Kozloduy. The design seismic loads for the site of Kozloduy NPP has been reevaluated and increased during and after the construction of investigated Units 5 and 6. Deterministic and probabilistic approaches are applied to assess the seismic vulnerability of the investigated structures, taking into account the newly defined seismic excitations. The presented results show sufficient seismic safety for the studied critical structures and good efficiency of the seismic upgrading. The applicability of the investigated structures at sites with some higher seismic activities is discussed. The presented study is dealing mainly with the civil structures of the Reactor building, Turbine hall, Diesel Generator Station and Water Intake Structure. (authors)

  12. Adaptive building skin structures

    International Nuclear Information System (INIS)

    Del Grosso, A E; Basso, P

    2010-01-01

    The concept of adaptive and morphing structures has gained considerable attention in the recent years in many fields of engineering. In civil engineering very few practical applications are reported to date however. Non-conventional structural concepts like deployable, inflatable and morphing structures may indeed provide innovative solutions to some of the problems that the construction industry is being called to face. To give some examples, searches for low-energy consumption or even energy-harvesting green buildings are amongst such problems. This paper first presents a review of the above problems and technologies, which shows how the solution to these problems requires a multidisciplinary approach, involving the integration of architectural and engineering disciplines. The discussion continues with the presentation of a possible application of two adaptive and dynamically morphing structures which are proposed for the realization of an acoustic envelope. The core of the two applications is the use of a novel optimization process which leads the search for optimal solutions by means of an evolutionary technique while the compatibility of the resulting configurations of the adaptive envelope is ensured by the virtual force density method

  13. Regional Design Approach in Designing Climatic Responsive Administrative Building in the 21st Century

    International Nuclear Information System (INIS)

    Mohidin, Hazrina Binti Haja Bava; Ismail, Alice Sabrina

    2015-01-01

    The objective of this paper is to explicate on the study of modern administrative building in Malaysia which portrays regional design approach that conforms to the local context and climate by reviewing two case studies; Perdana Putra (1999) and former Prime Minister's Office (1967). This paper is significant because the country's stature and political statement was symbolized by administrative building as a national icon. In other words, it is also viewed as a cultural object that is closely tied to a particular social context and nation historical moment. Administrative building, therefore, may exhibit various meanings. This paper uses structuralism paradigm and semiotic principles as a methodological approach. This paper is of importance for practicing architects and society in the future as it offers new knowledge and understanding in identifying the suitable climatic consideration that may reflect regionalist design approach in modern administrative building. These elements then may be adopted in designing public buildings in the future with regional values that are important for expressing national culture to symbolize the identity of place and society as well as responsive to climate change

  14. Structural design of the turbine building of Angra Nuclear Power Station, Unit 1

    International Nuclear Information System (INIS)

    Varella, L.N.; Reis, F.J.C.; Jurkiewicz, W.J.

    1978-01-01

    The Turbine Building of the Angra Nuclear Power Plant, Unit 1, and particularly its structure and structural design are described. The Turbine Building, as far as its structure is concerned, deviates from the standard structure of any turbine building due to the fact that huge ducts are provided in the foundation mat as to accomodate the circulating water system. This aspect and the fact that the building is founded upon a very deep strata of compacted and controlled fill, makes out of the building structure 'a concrete ship floating in the sea of sand', and by the same reason presents by itself an interesting structure, worth to be known to all engineers involved in design of power plants. This pape, suplemented by a few slides shown during presentation of the paper at the conference, covers the subject mainly from the designers' point of view. (Author)

  15. Experimental study of structural response to earthquakes

    International Nuclear Information System (INIS)

    Clough, R.W.; Bertero, V.V.; Bouwkamp, J.G.; Popov, E.P.

    1975-01-01

    The objectives, methods, and some of the principal results obtained from experimental studies of the behavior of structures subjected to earthquakes are described. Although such investigations are being conducted in many laboratories throughout the world, the information presented deals specifically with projects being carried out at the Earthquake Engineering Research Center (EERC) of the University of California, Berkeley. A primary purpose of these investigations is to obtain detailed information on the inelastic response mechanisms in typical structural systems so that the experimentally observed performance can be compared with computer generated analytical predictions. Only by such comparisons can the mathematical models used in dynamic nonlinear analyses be verified and improved. Two experimental procedures for investigating earthquake structural response are discussed: the earthquake simulator facility which subjects the base of the test structure to acceleration histories similar to those recorded in actual earthquakes, and systems of hydraulic rams which impose specified displacement histories on the test components, equivalent to motions developed in structures subjected to actual'quakes. The general concept and performance of the 20ft square EERC earthquake simulator is described, and the testing of a two story concrete frame building is outlined. Correlation of the experimental results with analytical predictions demonstrates that satisfactory agreement can be obtained only if the mathematical model incorporates a stiffness deterioration mechanism which simulates the cracking and other damage suffered by the structure

  16. Dynamic soil-structure interactions on embedded buildings

    International Nuclear Information System (INIS)

    Kobarg, J.; Werkle, H.; Henseleit, O.

    1983-01-01

    The dynamic soil-structure interaction on the horizontal seismic excitation is investigated on two typical embedded auxiliary buildings of a nuclear power plant. The structure and the soil are modelled by various analytical and numerical methods. Under the condition of the linear viscoelastic theory, i.e. soil characteristic constant in time and independent of strain, the interaction influences between a homogenous soil layer and a structure are analysied for the following parameters: 4) mathematical soil modells; 4) mathematical structure modells; 4) shear wave velocities; 3) embedment conditions; 4) earthquake time histories. (orig.) [de

  17. Comparative study for methods to determine the seismic response of NPP structures

    International Nuclear Information System (INIS)

    Varpasuo, P.

    1995-01-01

    There are many different important problem areas in evaluating the seismic response of structures. In this study the effort is concentrated on three of these areas. The first task is the mathematical formulation of earthquake excitation. The random vibration theory is taken as the tool in this task. The second area of interest in this study is the soil-structure interaction analysis. The approach of impedance functions is chosen and the focal point of interest is the significance of frequency dependent impedance functions. The third area of interest is the methods to determine the structural response. The following three methods were tested: the mode superposition time history method; the complex frequency response method; the response spectrum method. The comparison was made with the aid of MSC/NASTRAN code. The three methods gave for outer containment building response results which were in good agreement with each other. (author). 4 refs., 5 figs

  18. Extent of moisture and mould damage in structures of public buildings

    Directory of Open Access Journals (Sweden)

    Petri J. Annila

    2017-06-01

    Full Text Available The study concentrated on the extent of moisture and mould damage in different structures in 25 public buildings in Finland. Users of all the buildings had health symptoms suspected to be the result of moisture and mould damage, which is why moisture performance assessments had been performed. The assessment reports on each building were available as research material. The reports indicated that the examined buildings suffered from multiple moisture and mould problems in several different structures. On average, however, a relatively small proportion of the total number of structures had suffered damage. On the basis of the research material, damage was most extensive in walls in soil contact (16.3% and base floor structures (12.5%. The lowest damage rates were found in partition walls (2.4%, external walls (2.6% and intermediate floors (2.5%. The results of the study underline the importance of thorough moisture performance assessments to ensure that all point-sized moisture and mould damage is detected.

  19. Nuclear reactor buildings

    International Nuclear Information System (INIS)

    Nagashima, Shoji; Kato, Ryoichi.

    1985-01-01

    Purpose: To reduce the cost of reactor buildings and satisfy the severe seismic demands in tank type FBR type reactors. Constitution: In usual nuclear reactor buildings of a flat bottom embedding structure, the flat bottom is entirely embedded into the rock below the soils down to the deck level of the nuclear reactor. As a result, although the weight of the seismic structure can be decreased, the amount of excavating the cavity is significantly increased to inevitably increase the plant construction cost. Cross-like intersecting foundation mats are embedded to the building rock into a thickness capable withstanding to earthquakes while maintaining the arrangement of equipments around the reactor core in the nuclear buildings required by the system design, such as vertical relationship between the equipments, fuel exchange systems and sponteneous drainings. Since the rock is hard and less deformable, the rigidity of the walls and the support structures of the reactor buildings can be increased by the embedding into the rock substrate and floor responsivity can be reduced. This enables to reduce the cost and increasing the seismic proofness. (Kamimura, M.)

  20. Use of a viscoelastic model for the seismic response of base-isolated buildings

    International Nuclear Information System (INIS)

    Uras, R.A.

    1994-01-01

    Due to recent developments in elastomer technology, seismic isolation using elastomer bearings is rapidly becoming an acceptable design tool to enhance structural seismic margins and to protect people and equipment from earthquake damage. With proper design of isolators, high-energy seismic input motions are transformed into low-frequency, low energy harmonic motions and the accelerations acting on the isolated building are significantly reduced. Several alternatives exist for the modeling of the isolators. This study is concerned with the use of a viscoelastic model to predict the seismic response of base-isolated buildings. The in-house finite element computer code has been modified to incorporate a viscoelastic spring element, and several simulations are performed. Then, the computed results have been compared with the corresponding observed data recorded at the test facility

  1. Seismic response characteristics of full-size buildings with base isolation system

    International Nuclear Information System (INIS)

    Wang, C.Y.; Gvildys, J.

    1991-01-01

    This paper investigates the response characteristics of full-size reinforced concrete buildings via numerical simulations and actual observations. The test facility consists of two identical three-story buildings constructed side by side at Tohoku University in Sendai, Japan. Since the installation of high-damping isolation bearings in April 1989, data from over twenty earthquakes have been recorded. In this paper, three representative earthquake records, No. 2, No. 6, and No. 17 are used to study the detailed response characteristics. Numerical simulations are carried out with the system response program, SISEC. In general, good agreement has been found between numerical solutions and actual observations. The system is stiff enough to prevent the building displacement under minor earthquakes and wind loads, but is relatively soft for reducing the acceleration response during earthquakes with moderate and strong ground motion. Lessons learned in this effort are applicable to base isolation design of nuclear power plants. 7 refs., 16 figs., 3 tabs

  2. Non-linear finite element analysis for prediction of seismic response of buildings considering soil-structure interaction

    Directory of Open Access Journals (Sweden)

    E. Çelebi

    2012-11-01

    Full Text Available The objective of this paper focuses primarily on the numerical approach based on two-dimensional (2-D finite element method for analysis of the seismic response of infinite soil-structure interaction (SSI system. This study is performed by a series of different scenarios that involved comprehensive parametric analyses including the effects of realistic material properties of the underlying soil on the structural response quantities. Viscous artificial boundaries, simulating the process of wave transmission along the truncated interface of the semi-infinite space, are adopted in the non-linear finite element formulation in the time domain along with Newmark's integration. The slenderness ratio of the superstructure and the local soil conditions as well as the characteristics of input excitations are important parameters for the numerical simulation in this research. The mechanical behavior of the underlying soil medium considered in this prediction model is simulated by an undrained elasto-plastic Mohr-Coulomb model under plane-strain conditions. To emphasize the important findings of this type of problems to civil engineers, systematic calculations with different controlling parameters are accomplished to evaluate directly the structural response of the vibrating soil-structure system. When the underlying soil becomes stiffer, the frequency content of the seismic motion has a major role in altering the seismic response. The sudden increase of the dynamic response is more pronounced for resonance case, when the frequency content of the seismic ground motion is close to that of the SSI system. The SSI effects under different seismic inputs are different for all considered soil conditions and structural types.

  3. 209-E Building -- Response to ventilation failure evaluation

    International Nuclear Information System (INIS)

    Foust, D.J.

    1998-01-01

    This document provides an evaluation and recommendations for radiological workplace air monitoring and response to ventilation failure for the Critical Mass Laboratory, 209-E Building. The Critical Mass Laboratory, part of the 209-E Building, was designed to provide a heavily shielded room where plutonium and uranium liquid solutions could be brought into various critical configurations under readily controlled and monitored conditions. The facility is contained within a one-story L-shaped concrete block and reinforced concrete building. One wing houses offices, a control room, shops, and a common area while the other wing includes an equipment room, the change room, work areas, and the two-story Critical Assembly Room (CAR). Three of the rooms contain radiologically contaminated equipment and materials

  4. Soil-Structure Interaction Effect on Fragility Curve of 3D Models of Concrete Moment-Resisting Buildings

    Directory of Open Access Journals (Sweden)

    Ali Anvarsamarin

    2018-01-01

    Full Text Available This paper presents the probabilistic generation of collapse fragility curves for evaluating the performance of 3D, reinforced concrete (RC moment-resisting building models, considering soil-structure interaction (SSI by concentration on seismic uncertainties. It considers collapse as the loss of lateral load-resisting capacity of the building structures due to severe ground shaking and consequent large interstory drifts intensified by P-Δ effects as well as the strength and stiffness deterioration of their lateral load carrying systems. The estimation of the collapse performance of structures requires the relation between the intensity measure (IM and the probability of collapse that is determined using the generated collapse fragility curves. Considering a number of 6-, 12-, and 18-story, 3D, RC moment-resisting buildings, two scalar IMs are employed to estimate their collapse fragility curve. On the other hand, the effect of the site soil type on the collapse fragility curves was taken into account by considering the soil-structure interaction. According to the obtained results, adopting the average of spectral acceleration (Saavg intensity measure is more efficient in capturing the effect of the inherent uncertainties of the strong ground motions on the structural response parameters. In addition, considering the SSI for soil type D with shear-wave velocity of 180 m/s to 360 m/s reduces the median of intensity measure (IM = Sa(T1 of fragility curve in 6-, 12-, and 18-story buildings by 4.92%, 22.26%, and 23.03%, respectively.

  5. A SEISMIC DESIGN OF NUCLEAR REACTOR BUILDING STRUCTURES APPLYING SEISMIC ISOLATION SYSTEM IN A HIGH SEISMICITY REGION –A FEASIBILITY CASE STUDY IN JAPAN-

    Directory of Open Access Journals (Sweden)

    TETSUO KUBO

    2014-10-01

    Full Text Available A feasibility study on the seismic design of nuclear reactor buildings with application of a seismic isolation system is introduced. After the Hyogo-ken Nanbu earthquake in Japan of 1995, seismic isolation technologies have been widely employed for commercial buildings. Having become a mature technology, seismic isolation systems can be applied to NPP facilities in areas of high seismicity. Two reactor buildings are discussed, representing the PWR and BWR buildings in Japan, and the application of seismic isolation systems is discussed. The isolation system employing rubber bearings with a lead plug positioned (LRB is examined. Through a series of seismic response analyses using the so-named standard design earthquake motions covering the design basis earthquake motions obtained for NPP sites in Japan, the responses of the seismic isolated reactor buildings are evaluated. It is revealed that for the building structures examined herein: (1 the responses of both isolated buildings and isolating LRBs fulfill the specified design criteria; (2 the responses obtained for the isolating LRBs first reach the ultimate condition when intensity of motion is 2.0 to 2.5 times as large as that of the design-basis; and (3 the responses of isolated reactor building fall below the range of the prescribed criteria.

  6. Multi functional roof structures of the energy efficient buildings

    Directory of Open Access Journals (Sweden)

    Krstić Aleksandra

    2006-01-01

    Full Text Available Modern architectural concepts, which are based on rational energy consumption of buildings and the use of solar energy as a renewable energy source, give the new and significant role to the roofs that become multifunctional structures. Various energy efficient roof structures and elements, beside the role of protection, provide thermal and electric energy supply, natural ventilation and cooling of a building, natural lighting of the indoor space sunbeam protection, water supply for technical use, thus according to the above mentioned functions, classification and analysis of such roof structures and elements are made in this paper. The search for new architectural values and optimization in total energy balance of a building or the likewise for the urban complex, gave to roofs the role of "climatic membranes". Contemporary roof forms and materials clearly exemplify their multifunctional features. There are numerous possibilities to achieve the new and attractive roof design which broadens to the whole construction. With such inducement, this paper principally analyze the configuration characteristics of the energy efficient roof structures and elements, as well as the visual effects that may be achieved by their application.

  7. Earthquake response analyses of soil-structure system considering kinematic interaction

    International Nuclear Information System (INIS)

    Murakami, H.; Yokono, K.; Miura, S.; Ishii, K.

    1985-01-01

    Improvement of soil-structure interaction analysis has been one of major concerns in earthquake engineering field, especially in nuclear industries, to evaluate the safety of structure accurately under earthquake events. This research aims to develop a rational analytical tool which considers effect of the 'kinematic interaction' satisfactory with a proposed simple low-pass filter. In this paper, first the effect of the kinematic interaction is investigated based on earthquake response analysis of a reactor building using the practical design models: the spring-mass-dashpot system and the 'lattice model', in which a building and soil medium are modeled by a system of lumped masses. Next, the filter is developed based on parametrical studies with various sizes of depth and width of foundations embedded in two-layers soil, which represents more general soil condition in practical designs compared with a homogeneous soil medium. (orig.)

  8. Finding the displacement of wood structure in heritage building by 3D laser scanner

    Science.gov (United States)

    Lee, M. C.; Tsai, Y. L.; Wang, R. Z.; Lin, M. L.

    2015-08-01

    Heritage buildings are highly prone to long term damage from the microclimate, scourge and vandalism, which can result in damaged materials, structures, painting and cultural heritage items. This study will focus on finding the displacement of wood structural members through the use of a 3D laser scanner and the 4D concept of time. The results will compare the scans from different periods to find the difference (if any) in the structural member position. Wood structures usually consist of numerous wood members connected to form the structure. However, these members can be damaged in various ways such as physical mechanisms, chemical reactions, and biological corrosion. When damage to the wood structure occurs, the structural displacement can be affected, and if affected severely, can lead to a building collapse. Monitoring of the structural displacement is the best way to discover damage immediately and to preserve the heritage building. However, the Cultural Heritage Preservation Law in Taiwan prohibits the installation of monitoring instruments (e.g strain gauge, accelerometer) in historic structures (heritage buildings). Scanning the wood structure with 3D lasers is the most non-intrusive method and quickly achieves displacement through visualization. The displacement scan results can be compared with different periods and different members to analyze the severity of damage. Once the 3D scanner is installed, the whole building is scanned, and point clouds created to build the visual building model. The structural displacement can be checked via the building model and the differences are measured between each member to find the high risk damaged areas or members with large displacement. Early detection of structural damage is the most effective way means of preservation.

  9. LIFE-CYCLE COST MODEL AND DESIGN OPTIMIZATION OF BASE ISOLATED BUILDING STRUCTURES

    Directory of Open Access Journals (Sweden)

    Chara C. Mitropoulou

    2016-11-01

    Full Text Available Design of economic structures adequately resistant to withstand during their service life, without catastrophic failures, all possible loading conditions and to absorb the induced seismic energy in a controlled fashion, has been the subject of intensive research so far. Modern buildings usually contain extremely sensitive and costly equipment that are vital in business, commerce, education and/or health care. The building contents frequently are more valuable than the buildings them-selves. Furthermore, hospitals, communication and emergency centres, police and fire stations must be operational when needed most: immediately after an earthquake. Conventional con-struction can cause very high floor accelerations in stiff buildings and large interstorey drifts in flexible structures. These two factors cause difficulties in insuring the safety of both building and its contents. For this reason base-isolated structures are considered as an efficient alternative design practice to the conventional fixed-base one. In this study a systematic assessment of op-timized fixed and base-isolated reinforced concrete buildings is presented in terms of their initial and total cost taking into account the life-cycle cost of the structures.

  10. Seismic Response Prediction of Buildings with Base Isolation Using Advanced Soft Computing Approaches

    Directory of Open Access Journals (Sweden)

    Mosbeh R. Kaloop

    2017-01-01

    Full Text Available Modeling response of structures under seismic loads is an important factor in Civil Engineering as it crucially affects the design and management of structures, especially for the high-risk areas. In this study, novel applications of advanced soft computing techniques are utilized for predicting the behavior of centrically braced frame (CBF buildings with lead-rubber bearing (LRB isolation system under ground motion effects. These techniques include least square support vector machine (LSSVM, wavelet neural networks (WNN, and adaptive neurofuzzy inference system (ANFIS along with wavelet denoising. The simulation of a 2D frame model and eight ground motions are considered in this study to evaluate the prediction models. The comparison results indicate that the least square support vector machine is superior to other techniques in estimating the behavior of smart structures.

  11. On the influence of the foundation stiffness in the structural dynamic response

    International Nuclear Information System (INIS)

    Halbritter, A.L.; Koishi, N.; Stukart, R.N.L.

    1984-01-01

    To consider the influence of the foundation on the structural dynamic analysis, it is usual to represent the foundation stiffness by springs and the damping by snubbers, in the structural model. The stiffness and the damping values of the foundation can be determined by approximate methods based on simplifying assumptions, using, for example, the formula derived from the half space theory or numerical methods. The foundation stiffness has a great influence on the dynamic characteristics of the structure (eigenvalues and eigenvectors), and together with the damping influence the structural dynamic response. In this paper the influence of the foundation stiffness on the floor response spectra of the reactor building of a NPP of 1300 MW PWR of KWU type is studied. (Author) [pt

  12. RANDOM FUNCTIONS AND INTERVAL METHOD FOR PREDICTING THE RESIDUAL RESOURCE OF BUILDING STRUCTURES

    Directory of Open Access Journals (Sweden)

    Shmelev Gennadiy Dmitrievich

    2017-11-01

    Full Text Available Subject: possibility of using random functions and interval prediction method for estimating the residual life of building structures in the currently used buildings. Research objectives: coordination of ranges of values to develop predictions and random functions that characterize the processes being predicted. Materials and methods: when performing this research, the method of random functions and the method of interval prediction were used. Results: in the course of this work, the basic properties of random functions, including the properties of families of random functions, are studied. The coordination of time-varying impacts and loads on building structures is considered from the viewpoint of their influence on structures and representation of the structures’ behavior in the form of random functions. Several models of random functions are proposed for predicting individual parameters of structures. For each of the proposed models, its scope of application is defined. The article notes that the considered approach of forecasting has been used many times at various sites. In addition, the available results allowed the authors to develop a methodology for assessing the technical condition and residual life of building structures for the currently used facilities. Conclusions: we studied the possibility of using random functions and processes for the purposes of forecasting the residual service lives of structures in buildings and engineering constructions. We considered the possibility of using an interval forecasting approach to estimate changes in defining parameters of building structures and their technical condition. A comprehensive technique for forecasting the residual life of building structures using the interval approach is proposed.

  13. Radon entry into buildings: Effects of atmospheric pressure fluctuations and building structural factors

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Allen Lantham [Univ. of California, Berkeley, CA (United States). Dept. of Mechanical Engineering

    1996-05-01

    An improved understanding of the factors that control radon entry into buildings is needed in order to reduce the public health risks caused by exposure to indoor radon. This dissertation examines three issues associated with radon entry into buildings: (1) the influence of a subslab gravel layer and the size of the openings between the soil and the building interior on radon entry; (2) the effect of atmospheric pressure fluctuations on radon entry; and (3) the development and validation of mathematical models which simulate radon and soil-gas entry into houses. Experiments were conducted using two experimental basements to examine the influence of a subslab gravel layer on advective radon entry driven by steady indoor-outdoor pressure differences. These basement structures are identical except that in one the floor slab lies directly on native soil whereas in the other the slab lies on a high-permeability gravel layer. The measurements indicate that a high permeability subslab gravel layer increases the advective radon entry rate into the structure by as much as a factor of 30. The magnitude of the enhancement caused by the subslab gravel layer depends on the area of the openings in the structure floor; the smaller the area of these openings the larger the enhancement in the radon entry rate caused by the subslab gravel layer. A three-dimensional, finite-difference model correctly predicts the effect of a subslab gravel layer and open area configuration on advective radon entry driven by steady indoor-outdoor pressure differences; however, the model underpredicts the absolute entry rate into each structure by a factor of 1.5.

  14. Radon entry into buildings: Effects of atmospheric pressure fluctuations and building structural factors

    International Nuclear Information System (INIS)

    Robinson, A.L.

    1996-05-01

    An improved understanding of the factors that control radon entry into buildings is needed in order to reduce the public health risks caused by exposure to indoor radon. This dissertation examines three issues associated with radon entry into buildings: (1) the influence of a subslab gravel layer and the size of the openings between the soil and the building interior on radon entry; (2) the effect of atmospheric pressure fluctuations on radon entry; and (3) the development and validation of mathematical models which simulate radon and soil-gas entry into houses. Experiments were conducted using two experimental basements to examine the influence of a subslab gravel layer on advective radon entry driven by steady indoor-outdoor pressure differences. These basement structures are identical except that in one the floor slab lies directly on native soil whereas in the other the slab lies on a high-permeability gravel layer. The measurements indicate that a high permeability subslab gravel layer increases the advective radon entry rate into the structure by as much as a factor of 30. The magnitude of the enhancement caused by the subslab gravel layer depends on the area of the openings in the structure floor; the smaller the area of these openings the larger the enhancement in the radon entry rate caused by the subslab gravel layer. A three-dimensional, finite-difference model correctly predicts the effect of a subslab gravel layer and open area configuration on advective radon entry driven by steady indoor-outdoor pressure differences; however, the model underpredicts the absolute entry rate into each structure by a factor of 1.5

  15. New lumped-mass-stick model based on modal characteristics of structures: development and application to a nuclear containment building

    Science.gov (United States)

    Roh, Hwasung; Lee, Huseok; Lee, Jong Seh

    2013-06-01

    In this study, a new lumped-mass-stick model (LMSM) is developed based on the modal characteristics of a structure such as eigenvalues and eigenvectors. The simplified model, named the "frequency adaptive lumped-massstick model," hasonly a small number of stick elements and nodes to provide the same natural frequencies of the structure and is applied to a nuclear containment building. To investigate the numerical performance of the LMSM, a time history analysis is carried out on both the LMSM and the finite element model (FEM) for a nuclear containment building. A comparison of the results shows that the dynamic responses of the LMSM in terms of displacement and acceleration are almost identical to those of the FEM. In addition, the results in terms of fl oor response spectra at certain elevations are also in good agreement.

  16. Typological diversity of tall buildings and complexes in relation to their functional structure

    Science.gov (United States)

    Generalov, Viktor P.; Generalova, Elena M.; Kalinkina, Nadezhda A.; Zhdanova, Irina V.

    2018-03-01

    The paper focuses on peculiarities of tall buildings and complexes, their typology and its formation in relation to their functional structure. The research is based on the analysis of tall buildings and complexes and identifies the following main functional elements of their formation: residential, administrative (office), hotel elements. The paper also considers the following services as «disseminated» in the space-planning structure: shops, medicine, entertainment, kids and sports facilities, etc., their location in the structure of the total bulk of the building and their impact on typological diversity. Research results include suggestions to add such concepts as «single-function tall buildings» and «mixed-use tall buildings and complexes» into the classification of tall buildings. In addition, if a single-function building or complex performs serving functions, it is proposed to add such concepts as «a residential tall building (complex) with provision of services», «an administrative (public) tall building (complex) with provision of services» into the classification of tall buildings. For mixed-use buildings and complexes the following terms are suggested: «a mixed-use tall building with provision of services», «a mixed-use tall complex with provision of services».

  17. Space-planning and structural solutions of low-rise buildings: Optimal selection methods

    Science.gov (United States)

    Gusakova, Natalya; Minaev, Nikolay; Filushina, Kristina; Dobrynina, Olga; Gusakov, Alexander

    2017-11-01

    The present study is devoted to elaboration of methodology used to select appropriately the space-planning and structural solutions in low-rise buildings. Objective of the study is working out the system of criteria influencing the selection of space-planning and structural solutions which are most suitable for low-rise buildings and structures. Application of the defined criteria in practice aim to enhance the efficiency of capital investments, energy and resource saving, create comfortable conditions for the population considering climatic zoning of the construction site. Developments of the project can be applied while implementing investment-construction projects of low-rise housing at different kinds of territories based on the local building materials. The system of criteria influencing the optimal selection of space-planning and structural solutions of low-rise buildings has been developed. Methodological basis has been also elaborated to assess optimal selection of space-planning and structural solutions of low-rise buildings satisfying the requirements of energy-efficiency, comfort and safety, and economical efficiency. Elaborated methodology enables to intensify the processes of low-rise construction development for different types of territories taking into account climatic zoning of the construction site. Stimulation of low-rise construction processes should be based on the system of approaches which are scientifically justified; thus it allows enhancing energy efficiency, comfort, safety and economical effectiveness of low-rise buildings.

  18. Structural analysis of reactor buildings with help of complete FE models

    International Nuclear Information System (INIS)

    Diaz, B.E.; Vaz, L.E.; Martha, L.F.R.; Costa, E.

    1984-01-01

    The reinforced concrete structures located within the steel containment shell of a Reactor Building are formed by highly complex structures subjected to a large amount of actions due to different causes. The analysis of this complex structure can be performed with help of small models, each one representing a part of the global structure. The interaction effects among the partial models are accounted for in approximate way. This approach has been used previously with entire success in the design of 1300 MW PWR nuclear power plants. However a new and entire different approach can be used in the design of these structures. The entire assembly of structural elements of the building is represented and analyzed with help of a single and very large FE model. This paper will present the main characteristics of this type of analysis as well as all the necessary procedures, which must be implemented for the proper data processing of the forces and the automatic reinforced concrete design of the structural elements of the Reactor Building. (Author) [pt

  19. Structural evaluation of the 2736Z Building for seismic loads

    International Nuclear Information System (INIS)

    Giller, R.A.

    1994-01-01

    The 2736Z building structure is evaluated for high-hazard loads. The 2736Z building is analyzed herein for normal and seismic loads and is found to successfully meet the guidelines of UCRL-15910 along with the related codes requirements

  20. Object-Based Dense Matching Method for Maintaining Structure Characteristics of Linear Buildings.

    Science.gov (United States)

    Su, Nan; Yan, Yiming; Qiu, Mingjie; Zhao, Chunhui; Wang, Liguo

    2018-03-29

    In this paper, we proposed a novel object-based dense matching method specially for the high-precision disparity map of building objects in urban areas, which can maintain accurate object structure characteristics. The proposed framework mainly includes three stages. Firstly, an improved edge line extraction method is proposed for the edge segments to fit closely to building outlines. Secondly, a fusion method is proposed for the outlines under the constraint of straight lines, which can maintain the building structural attribute with parallel or vertical edges, which is very useful for the dense matching method. Finally, we proposed an edge constraint and outline compensation (ECAOC) dense matching method to maintain building object structural characteristics in the disparity map. In the proposed method, the improved edge lines are used to optimize matching search scope and matching template window, and the high-precision building outlines are used to compensate the shape feature of building objects. Our method can greatly increase the matching accuracy of building objects in urban areas, especially at building edges. For the outline extraction experiments, our fusion method verifies the superiority and robustness on panchromatic images of different satellites and different resolutions. For the dense matching experiments, our ECOAC method shows great advantages for matching accuracy of building objects in urban areas compared with three other methods.

  1. Object-Based Dense Matching Method for Maintaining Structure Characteristics of Linear Buildings

    Directory of Open Access Journals (Sweden)

    Nan Su

    2018-03-01

    Full Text Available In this paper, we proposed a novel object-based dense matching method specially for the high-precision disparity map of building objects in urban areas, which can maintain accurate object structure characteristics. The proposed framework mainly includes three stages. Firstly, an improved edge line extraction method is proposed for the edge segments to fit closely to building outlines. Secondly, a fusion method is proposed for the outlines under the constraint of straight lines, which can maintain the building structural attribute with parallel or vertical edges, which is very useful for the dense matching method. Finally, we proposed an edge constraint and outline compensation (ECAOC dense matching method to maintain building object structural characteristics in the disparity map. In the proposed method, the improved edge lines are used to optimize matching search scope and matching template window, and the high-precision building outlines are used to compensate the shape feature of building objects. Our method can greatly increase the matching accuracy of building objects in urban areas, especially at building edges. For the outline extraction experiments, our fusion method verifies the superiority and robustness on panchromatic images of different satellites and different resolutions. For the dense matching experiments, our ECOAC method shows great advantages for matching accuracy of building objects in urban areas compared with three other methods.

  2. Criteria of choosing building structures for rooftop boiler rooms

    Directory of Open Access Journals (Sweden)

    Plotnikov Artyom

    2018-01-01

    Full Text Available The paper investigates parameters of noise and vibration distribution in the territory of residential area depending on the structural materials and power of independent heat supply systems. Rooftop boiler rooms are decentralized heat supply systems in buildings. Today, residential areas are strongly affected by noise and vibrations. Adverse effects are isolated by buildings materials, protective shields and floating floors. Rooftop boiler rooms located in Tyumen city were investigated within this research. Structures of rooftop boiler rooms were analyzed. Acoustic analysis results and the parameters of equivalent continuous sound level are presented. An option for improvement of rooftop boiler rooms structures is suggested. Comparison of capital investments in construction and installation activities is carried out. Conclusion on capital investments required for noise protection is made.

  3. 49 CFR 41.119 - DOT regulated buildings.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false DOT regulated buildings. 41.119 Section 41.119 Transportation Office of the Secretary of Transportation SEISMIC SAFETY § 41.119 DOT regulated buildings. (a) Each DOT Operating Administration with responsibility for regulating the structural safety of buildings...

  4. Effects of non-structural components and soil-structure interaction on the seismic response of framed structures

    Science.gov (United States)

    Ditommaso, Rocco; Auletta, Gianluca; Iacovino, Chiara; Nigro, Antonella; Carlo Ponzo, Felice

    2017-04-01

    In this paper, several nonlinear numerical models of reinforced concrete framed structures have been defined in order to evaluate the effects of non-structural elements and soil-structure interaction on the elastic dynamic behaviour of buildings. In the last few years, many and various studies have highlighted the significant effects derived from the interaction between structural and non-structural components on the main dynamic characteristics of a building. Usually, structural and non-structural elements act together, adding both masses and stiffness. The presence of infill panels is generally neglected in the design process of structural elements, although these elements can significantly increase the lateral stiffness of a structure leading to a modification in the dynamic properties. Particularly, at the Damage Limit State (where an elastic behaviour is expected), soil-structure interaction effects and non-structural elements may further affect the elastic natural period of buildings, changing the spectral accelerations compared with those provided by seismic codes in case of static analyses. In this work, a parametric study has been performed in order to evaluate the elastic fundamental period of vibration of buildings as a function of structural morphology (height, plan area, ratio between plan dimensions), infills presence and distribution and soil characteristics. Acknowledgements This study was partially funded by the Italian Department of Civil Protection within the project DPC-RELUIS 2016 - RS4 ''Seismic observatory of structures and health monitoring'' and by the "Centre of Integrated Geomorphology for the Mediterranean Area - CGIAM" within the Framework Agreement with the University of Basilicata "Study, Research and Experimentation in the Field of Analysis and Monitoring of Seismic Vulnerability of Strategic and Relevant Buildings for the purposes of Civil Protection and Development of Innovative Strategies of Seismic Reinforcement".

  5. Study on vertical seismic response characteristics of deeply embedded reactor building

    International Nuclear Information System (INIS)

    Morishita, H.; Nakamura, N.; Uchiyama, S.; Fukuoka, A.; Ishizaki, M.

    1993-01-01

    This paper describes vertical response characteristics, especially effects of embedment, and analytical methods for seismic design of a deeply embedded reactor building. The influence of embedment on vertical response was found to be minimal by evaluating results of forced vibration tests of a reactor building model and performing simplified analyses. Subsequently, simulation analyses of the forced vibration test and actual earthquake induced response were performed using both the axisymmetric FEM model and the simplified mass and spring model. It was concluded that the analytical models taking the embedment into the consideration closely simulated the observation records, and the omission of embedment in the analyses tended to increase the predicted response which was conservative in respect an actual design consideration. (author)

  6. Automated structure solution, density modification and model building.

    Science.gov (United States)

    Terwilliger, Thomas C

    2002-11-01

    The approaches that form the basis of automated structure solution in SOLVE and RESOLVE are described. The use of a scoring scheme to convert decision making in macromolecular structure solution to an optimization problem has proven very useful and in many cases a single clear heavy-atom solution can be obtained and used for phasing. Statistical density modification is well suited to an automated approach to structure solution because the method is relatively insensitive to choices of numbers of cycles and solvent content. The detection of non-crystallographic symmetry (NCS) in heavy-atom sites and checking of potential NCS operations against the electron-density map has proven to be a reliable method for identification of NCS in most cases. Automated model building beginning with an FFT-based search for helices and sheets has been successful in automated model building for maps with resolutions as low as 3 A. The entire process can be carried out in a fully automatic fashion in many cases.

  7. Irregular Shaped Building Design Optimization with Building Information Modelling

    Directory of Open Access Journals (Sweden)

    Lee Xia Sheng

    2016-01-01

    Full Text Available This research is to recognise the function of Building Information Modelling (BIM in design optimization for irregular shaped buildings. The study focuses on a conceptual irregular shaped “twisted” building design similar to some existing sculpture-like architectures. Form and function are the two most important aspects of new buildings, which are becoming more sophisticated as parts of equally sophisticated “systems” that we are living in. Nowadays, it is common to have irregular shaped or sculpture-like buildings which are very different when compared to regular buildings. Construction industry stakeholders are facing stiff challenges in many aspects such as buildability, cost effectiveness, delivery time and facility management when dealing with irregular shaped building projects. Building Information Modelling (BIM is being utilized to enable architects, engineers and constructors to gain improved visualization for irregular shaped buildings; this has a purpose of identifying critical issues before initiating physical construction work. In this study, three variations of design options differing in rotating angle: 30 degrees, 60 degrees and 90 degrees are created to conduct quantifiable comparisons. Discussions are focused on three major aspects including structural planning, usable building space, and structural constructability. This research concludes that Building Information Modelling is instrumental in facilitating design optimization for irregular shaped building. In the process of comparing different design variations, instead of just giving “yes or no” type of response, stakeholders can now easily visualize, evaluate and decide to achieve the right balance based on their own criteria. Therefore, construction project stakeholders are empowered with superior evaluation and decision making capability.

  8. Structure soil structure interaction effects: Seismic analysis of safety related collocated concrete structures

    International Nuclear Information System (INIS)

    Joshi, J.R.

    2000-01-01

    The Process, Purification and Stack Buildings are collocated safety related concrete shear wall structures with plan dimensions in excess of 100 feet. An important aspect of their seismic analysis was the determination of structure soil structure interaction (SSSI) effects, if any. The SSSI analysis of the Process Building, with one other building at a time, was performed with the SASSI computer code for up to 50 frequencies. Each combined model had about 1500 interaction nodes. Results of the SSSI analysis were compared with those from soil structure interaction (SSI) analysis of the individual buildings, done with ABAQUS and SASSI codes, for three parameters: peak accelerations, seismic forces and the in-structure floor response spectra (FRS). The results may be of wider interest due to the model size and the potential applicability to other deep soil layered sites. Results obtained from the ABAQUS analysis were consistently higher, as expected, than those from the SSI and SSSI analyses using the SASSI. The SSSI effect between the Process and Purification Buildings was not significant. The Process and Stack Building results demonstrated that under certain conditions a massive structure can have an observable effect on the seismic response of a smaller and less stiff structure

  9. Building materials. Structure and technology, types and properties, application and handlings. 2. rev. ed. Baustoffkunde. Aufbau und Technologie, Arten und Eigenschaften, Anwendung und Verarbeitung der Baustoffe

    Energy Technology Data Exchange (ETDEWEB)

    Schaeffler, H

    1980-01-01

    Details are given on the large variety of structural and interior building materials. Reference is made to the relation between the structure and technology of building materials on one hand and the properties and handling of building materials on the other hand. The following subjects are dealt with: Fundamentals (historical development, systematy of building materials, regulations, properties, property warranties); natural stone; lumber and derived lumber products (properties, species of lumber, flaws, supply cuts); ceramic building materials and glass (brick, earthenware, refractory materials); building materials with mineral binders added, concrete and mortar (technology, setting); metals (properties, technology); bituminous building materials (technology, properties); plastics (thermoplasts, elastomers, duroplastics, paints, adhesives, synthetic-resin mortar and synthetic-resin concrete); insulating materials, organic floor coverings, papers and paperboard, paints, adhesives and sealing materials; damage to buildings (types, causes, responsibility, avoidance). (HWJ).

  10. Prerequisites for building a computer security incident response capability

    CSIR Research Space (South Africa)

    Mooi, M

    2015-08-01

    Full Text Available . 1]. 2) Handbook for Computer Security Incident Response Teams (CSIRTs) [18] (CMU-SEI): Providing guidance on building and running a CSIRT, this handbook has a particular focus on the incident handling service [18, p. xv]. In addition, a basic CSIRT... stream_source_info Mooi_2015.pdf.txt stream_content_type text/plain stream_size 41092 Content-Encoding UTF-8 stream_name Mooi_2015.pdf.txt Content-Type text/plain; charset=UTF-8 Prerequisites for building a computer...

  11. Demand Response Resource Quantification with Detailed Building Energy Models

    Energy Technology Data Exchange (ETDEWEB)

    Hale, Elaine; Horsey, Henry; Merket, Noel; Stoll, Brady; Nag, Ambarish

    2017-04-03

    Demand response is a broad suite of technologies that enables changes in electrical load operations in support of power system reliability and efficiency. Although demand response is not a new concept, there is new appetite for comprehensively evaluating its technical potential in the context of renewable energy integration. The complexity of demand response makes this task difficult -- we present new methods for capturing the heterogeneity of potential responses from buildings, their time-varying nature, and metrics such as thermal comfort that help quantify likely acceptability of specific demand response actions. Computed with an automated software framework, the methods are scalable.

  12. Structural vibration passive control and economic analysis of a high-rise building in Beijing

    Science.gov (United States)

    Chen, Yongqi; Cao, Tiezhu; Ma, Liangzhe; Luo, Chaoying

    2009-12-01

    Performance analysis of the Pangu Plaza under earthquake and wind loads is described in this paper. The plaza is a 39-story steel high-rise building, 191 m high, located in Beijing close to the 2008 Olympic main stadium. It has both fluid viscous dampers (FVDs) and buckling restrained braces or unbonded brace (BRB or UBB) installed. A repeated iteration procedure in its design and analysis was adopted for optimization. Results from the seismic response analysis in the horizontal and vertical directions show that the FVDs are highly effective in reducing the response of both the main structure and the secondary system. A comparative analysis of structural seismic performance and economic impact was conducted using traditional methods, i.e., increased size of steel columns and beams and/or use of an increased number of seismic braces versus using FVD. Both the structural response and economic analysis show that using FVD to absorb seismic energy not only satisfies the Chinese seismic design code for a “rare” earthquake, but is also the most economical way to improve seismic performance both for one-time direct investment and long term maintenance.

  13. Demand Response Technology Readiness Levels for Energy Management in Blocks of Buildings

    Directory of Open Access Journals (Sweden)

    Tracey Crosbie

    2018-01-01

    Full Text Available Fossil fuels deliver most of the flexibility in contemporary electricity systems. The pressing need to reduce CO2 emissions requires new methods to provide this flexibility. Demand response (DR offers consumers a significant role in the delivery of flexibility by reducing or shifting their electricity usage during periods of stress or constraint. Blocks of buildings offer more flexibility in the timing and use of energy than single buildings, however, and a lack of relevant scalable ICT tools hampers DR in blocks of buildings. To ameliorate this problem, a current innovation project called “Demand Response in Blocks of Buildings” (DR-BoB: www.dr-bob.eu has integrated existing technologies into a scalable cloud-based solution for DR in blocks of buildings. The degree to which the DR-BoB energy management solution can increase the ability of any given site to participate in DR is dependent upon its current energy systems, i.e., the energy metering, the telemetry and control technologies in building management systems, and the existence/capacity of local power generation and storage plants. To encourage the owners and managers of blocks of buildings to participate in DR, a method of assessing and validating the technological readiness to participate in DR energy management solutions at any given site is required. This paper describes the DR-BoB energy management solution and outlines what we have called the demand response technology readiness levels (DRTRLs for the implementation of such a solution in blocks of buildings.

  14. First-passage Probability Estimation of an Earthquake Response of Seismically Isolated Containment Buildings

    International Nuclear Information System (INIS)

    Hahm, Dae-Gi; Park, Kwan-Soon; Koh, Hyun-Moo

    2008-01-01

    The awareness of a seismic hazard and risk is being increased rapidly according to the frequent occurrences of the huge earthquakes such as the 2008 Sichuan earthquake which caused about 70,000 confirmed casualties and a 20 billion U.S. dollars economic loss. Since an earthquake load contains various uncertainties naturally, the safety of a structural system under an earthquake excitation has been assessed by probabilistic approaches. In many structural applications for a probabilistic safety assessment, it is often regarded that the failure of a system will occur when the response of the structure firstly crosses the limit barrier within a specified interval of time. The determination of such a failure probability is usually called the 'first-passage problem' and has been extensively studied during the last few decades. However, especially for the structures which show a significant nonlinear dynamic behavior, an effective and accurate method for the estimation of such a failure probability is not fully established yet. In this study, we presented a new approach to evaluate the first-passage probability of an earthquake response of seismically isolated structures. The proposed method is applied to the seismic isolation system for the containment buildings of a nuclear power plant. From the numerical example, we verified that the proposed method shows accurate results with more efficient computational efforts compared to the conventional approaches

  15. Effects of different SSI parameters on the floor response spectra of a nuclear reactor building

    International Nuclear Information System (INIS)

    Kabir, A.F.; Bolourchi, S.; Maryak, M.E.

    1991-01-01

    The effects of several critical soil-structure interaction (SSI) parameters on the floor response spectra (FRS) of a typical nuclear reactor building have been examined. These parameters are computation of soil impedance functions using different approaches, scattering effects (reductions in ground motion due to embedment and rigidity of building foundation) and strain dependency of soil dynamic properties. This paper reports that the significant conclusions of the study, which are applicable to a deeply embedded very rigid nuclear reactor building, are as follows: FRS generated without considering scattering effects are highly conservative; differences between FRS, generated considering strain-dependency of soil dynamic properties, and those generated suing low-strain values, are not significant; and the lumped-parameter approach of SSI calculations, which only uses a single value of soil shear modulus in impedance calculations, may not be able to properly compute the soil impedances for a soil deposit with irregularly varying properties with depth

  16. State-of-the-art Review : Vol. 2A. Responsive Building Elements

    DEFF Research Database (Denmark)

    Blümel, Ernst; Haghighat, Fariborz; Li, Yuguo

    This report resumes and presents the activity done in Subtask A of IEA-ECBCS Annex 44 “Integrating Environmentally Responsive Elements in Buildings” concerning the state of the art review of Responsive Building Elements. It is based on the contributions from the participating countries...... at researchers in the field and gives an overview of how these elements work together with available performance data. It is hoped, that this report will be helpful for researchers in their search for new solutions to the problem of designing and constructing sustainable buildings....

  17. The significance of the structural regularity for the seismic response of buildings

    International Nuclear Information System (INIS)

    Hampe, E.; Goldbach, R.; Schwarz, J.

    1991-01-01

    The paper gives an state-of-the-art report about the international design practice and submits fundamentals for a systematic approach to the solution of that problem. Different criteria of regularity are presented and discussed with respect to EUROCODE Nr. 8. Still remaining questions and the main topics of future research activities are announced and come into consideration. Frame structures with or without additional stiffening wall elements are investigated to illustrate the qualitative differences of the vibrational properties and the earthquake response of regular and irregular systems. (orig./HP) [de

  18. Life management for a non replaceable structure: the reactor building

    International Nuclear Information System (INIS)

    Torres, V.; Francia, L.

    1998-01-01

    Phase 1 of UNESA N.P.P. Lifetime Management Project identified and ranked important components, relative to plant life management. The list showed the Reactor Containment Structure in the third position, and thirteen concrete structures were among the list top twenty. Since the Reactor Containment Building, together with the Reactor Vessel, is the only non-replaceable plant component, and has a big impact on the plant technical life, there is an increasing interest on understanding its behavior to maintain structural integrity. This paper presents: a) IAEA (International Atomic Energy Agency) Coordinated Research Program experiences and studies. Under this Program, international experts address the most frequent degradation mechanisms affecting the containment building. b) IAEA Aging Management Program adapted to our plants. The paper addresses the aging mechanisms affecting the concrete structures, reinforcing steel and prestress systems as well as the aging management programs and the mitigation and control methods. Finally, this paper presents a new module called STRUCTURES, included in phase 2 of the above mentioned project, which will monitor and document the different aging mechanisms and management programs described in item b) regarding the Reactor Containment Building (concrete liner, post stressing system, anchor elements). This module will also support the Maintenance Rule related practices. (Author)

  19. Climate responsive and safe earthquake construction: a community building a school

    Directory of Open Access Journals (Sweden)

    Hari Darshan

    2011-10-01

    Full Text Available This article outlines environment friendly features, climate responsive features and construction features of a prototype school building constructed using green building technology. The school building has other additional features such as earthquake resistant construction, use of local materials and local technology. The construction process not only establishes community ownership, but also facilitates dissemination of the technology to the communities. Schools are effective media for raising awareness, disseminating technology and up-scaling the innovative approach. The approach is cost effective and sustainable for long-term application of green building technology. Furthermore, this paper emphasizes that such construction technology will be instrumental to build culture of safety in communities and reduce disaster risk.

  20. Toolbox for super-structured and super-structure free multi-disciplinary building spatial design optimisation

    NARCIS (Netherlands)

    Boonstra, S.; van der Blom, K.; Hofmeyer, H.; Emmerich, M.T.M.; van Schijndel, A.W.M.; de Wilde, P.

    2018-01-01

    Multi-disciplinary optimisation of building spatial designs is characterised by large solution spaces. Here two approaches are introduced, one being super-structured and the other super-structure free. Both are different in nature and perform differently for large solution spaces and each requires

  1. Internal structure of reactor building for Madras Atomic Power Project

    International Nuclear Information System (INIS)

    Pandit, D.P.

    1975-01-01

    The structural configuration and analysis of structural elements of the internal structure of reactor building for the Madras Atomic Power Project has been presented. Two methods of analysis of the internal structure, viz. Equivalent Plane Frame and Finite Element Method, are explained and compared with the use of bending moments obtained. (author)

  2. An approach to separating the levels of hierarchical structure building in language and mathematics.

    Science.gov (United States)

    Makuuchi, Michiru; Bahlmann, Jörg; Friederici, Angela D

    2012-07-19

    We aimed to dissociate two levels of hierarchical structure building in language and mathematics, namely 'first-level' (the build-up of hierarchical structure with externally given elements) and 'second-level' (the build-up of hierarchical structure with internally represented elements produced by first-level processes). Using functional magnetic resonance imaging, we investigated these processes in three domains: sentence comprehension, arithmetic calculation (using Reverse Polish notation, which gives two operands followed by an operator) and a working memory control task. All tasks required the build-up of hierarchical structures at the first- and second-level, resulting in a similar computational hierarchy across language and mathematics, as well as in a working memory control task. Using a novel method that estimates the difference in the integration cost for conditions of different trial durations, we found an anterior-to-posterior functional organization in the prefrontal cortex, according to the level of hierarchy. Common to all domains, the ventral premotor cortex (PMv) supports first-level hierarchy building, while the dorsal pars opercularis (POd) subserves second-level hierarchy building, with lower activation for language compared with the other two tasks. These results suggest that the POd and the PMv support domain-general mechanisms for hierarchical structure building, with the POd being uniquely efficient for language.

  3. Structural and compositional features of high-rise buildings: experimental design in Yekaterinburg

    Science.gov (United States)

    Yankovskaya, Yulia; Lobanov, Yuriy; Temnov, Vladimir

    2018-03-01

    The study looks at the specifics of high-rise development in Yekaterinburg. High-rise buildings are considered in the context of their historical development, structural features, compositional and imaginative design techniques. Experience of Yekaterinburg architects in experimental design is considered and analyzed. Main issues and prospects of high-rise development within the Yekaterinburg structure are studied. The most interesting and significant conceptual approaches to the structural and compositional arrangement of high-rise buildings are discussed.

  4. Study of seismic responses of Candu-3 reactor building using isolator bearings

    International Nuclear Information System (INIS)

    Biswas, J.K.

    1992-01-01

    Seismic isolator bearings are known to increase reliability, reduce cost and increase the potential sitings for nuclear power plants located in regions of high seismicity. High seismic activities in Canada occur mainly in the western coast, the Grand Banks and regions of Quebec along the St. Lawrence river. In Canada, nuclear power plants are located in Ontario, Quebec and New Brunswick where the seismicity levels are low to moderate. Consequently, seismic isolator bearings have not been used in the existing nuclear power plants in Canada. The present paper examines the effect of using seismic isolator bearings in the design for the new CANDU3 which would be suitable for regions having high seismicity. The CANDU3 Nuclear Power Plant is rated at 450 MW of net output power and is a smaller version of its predecessor CANDU6 successfully operating in Canada and abroad. The design of CANDU3 is being developed by AECL CANDU. Advanced technologies for design, construction and plant operation have been utilized. During the conceptual development of the CANDU3 design, various design options including the use of isolator bearings were considered. The present paper presents an overview of seismic isolation technology and summarizes the analytical work for predicting the seismic behavior of the CANDU3 reactor building. A lumped-parameter dynamic model for the reactor building is used for the analysis. The characteristics of the bearings are utilized in the analysis work. The time-history modal analysis has been used to compute the seismic responses. Seismic responses of the reactor building with and without isolator bearings are compared. The isolator bearings are found to reduce the accelerations of the reactor building. As a result, a lower level of seismic qualification for components and systems would be required. The use of these bearings however increases rigid body seismic displacements of the structure requiring special considerations in the layout and interfaces for

  5. Methodology for estimating realistic responses of buildings and components under earthquake motion and its application

    International Nuclear Information System (INIS)

    Ebisawa, Katsumi; Abe, Kiyoharu; Kohno, Kunihiko; Nakamura, Hidetaka; Itoh, Mamoru.

    1996-11-01

    Failure probabilities of buildings and components under earthquake motion are estimated as conditional probabilities that their realistic responses exceed their capacities. Two methods for estimating their failure probabilities have already been developed. One is a detailed method developed in the Seismic Safety margins Research Program of Lawrence Livermore National Laboratory in U.S.A., which is called 'SSMRP method'. The other is a simplified method proposed by Kennedy et al., which is called 'Zion method'. The Zion method is sometimes called 'response factor method'. The authors adopted the response factor method. In order to enhance the estimation accuracy of failure probabilities of buildings and components, however, a new methodology for improving the response factor method was proposed. Based on the improved method, response factors of buildings and components designed to seismic design standard in Japan were estimated, and their realistic responses were also calculated. By using their realistic responses and capacities, the failure probabilities of a reactor building and relays were estimated. In order to identify the difference between new method, SSMRP method and original response factor method, the failure probabilities were compared estimated by these three methods. A similar method of SSMRP was used instead of the original SSMRP for saving time and labor. The viewpoints for selecting the methods to estimate failure probabilities of buildings and components were also proposed. (author). 55 refs

  6. Response spectrum analysis of coupled structural response to a three component seismic disturbance

    International Nuclear Information System (INIS)

    Boulet, J.A.M.; Carley, T.G.

    1977-01-01

    The work discussed herein is a comparison and evaluation of several response spectrum analysis (RSA) techniques as applied to the same structural model with seismic excitation having three spatial components. The structural model includes five lumped masses (floors) connected by four elastic members. The base is supported by three translational springs and two horizontal torsional springs. In general, the mass center and shear center of a building floor are distinct locations. Hence, inertia forces, which act at the mass center, induce twisting in the structure. Through this induced torsion, the lateral (x and y) displacements of the mass elements are coupled. The ground motion components used for this study are artificial earthquake records generated from recorded accelerograms by a spectrum modification technique. The accelerograms have response spectra which are compatible with U.S. NRC Regulatory Guide 1.60. Lagrange's equations of motion for the system were written in matrix form and uncoupled with the modal matrix. Numerical integration (fourth order Runge-Kutta) of the resulting modal equations produced time histories of system displacements in response to simultaneous application of three orthogonal components of ground motion, and displacement response spectra for each modal coordinate in response to each of the three ground motion components. Five different RSA techniques were used to combine the spectral displacements and the modal matrix to give approximations of maximum system displacements. These approximations were then compared with the maximum system displacements taken from the time histories. The RSA techniques used are the method of absolute sums, the square root of the sum of the sum of the squares, the double sum approach, the method of closely spaced modes, and Lin's method

  7. Effect of support conditions on structural response under dynamic loading

    International Nuclear Information System (INIS)

    Akram, T.; Memon, S.A.

    2008-01-01

    In design practice, dynamic structural analysis is carried out with base of structure considered as fixed; this means that foundation is placed on rock like soil material. While conducting this type of analyses the role of foundation and soil behaviour is totally neglected. The actions in members and loads transferred at foundation level obtained in this manner do not depict the true structural behaviour. FEM (Finite Element Methods) analysis where both superstructure and foundation soil are coupled together is quite complicated and expensive for design environments. A simplified model is required to depict dynamic response of structures with foundations based on flexible soils. The primary purpose of this research is to compare the superstructure dynamic responses of structural systems with fixed base to that of simple soil model base. The selected simple soil model is to be suitable for use in a design environment to give more realistic results. For this purpose building models are idealized with various heights and structural systems in both 2D (Two Dimensional) and 3D (Three Dimensional) space. These models are then provided with visco-elastic supports representing three soil bearing capacities and the analysis results are compared to that of fixed supports models. The results indicate that fixed support system underestimates natural time period of the structures. Dynamic behavior and force response of visco-elastic support is different from fixed support model. Fixed support models result in over designed base columns and under designed beams. (author)

  8. Vibration-damping structure for reactor building

    International Nuclear Information System (INIS)

    Kuno, Toshio; Iba, Chikara; Tanaka, Hideki; Kageyama, Mitsuru

    1998-01-01

    In a damping structure of a reactor building, an inner concrete body and a reactor container are connected by way of a vibration absorbing member. As the vibration absorbing member, springs or dampers are used. The inner concrete body and the reactor container each having weight and inherent frequency different from each other are opposed displaceably by way of the vibration absorbing member thereby enabling to reduce seismic input and reduce shearing force at least at leg portions. Accordingly, seismic loads are reduced to increase the grounding rate of the base thereby enabling to satisfy an allowable value. Therefore, it is not necessary to strengthen the inner concrete body and the reactor container excessively, the amount of reinforcing rods can be reduced, and the amount of a portion of the base buried to the ground can be reduced thereby enabling to constitute the reactor building easily. (N.H.)

  9. Adaptation of high viscous dampers (HVD) for essential decreasing of in-structure floor response spectra

    International Nuclear Information System (INIS)

    Kostarev, V.V.; Petrenko, A.V.; Vasilyev, P.S.; Reinsch, K.-H.

    2005-01-01

    This paper concerns a further development of High Viscous Damper (HVD) approach for essential decreasing of structure's floor response spectra. Usually restraining of components and pipelines by HVD is used for significant decreasing of operational vibration and seismic loads. A new approach consists of dampers installation for essential upgrading of a whole system's damping that is much more efficient in both technical and economical points of view than restraining of each component of the system. In that way using of HVD means high energy dissipation for whole dynamic system 'Building-Components' subjected to the base seismic or other extreme load excitation. The specific feature of each NPP site is an existing of a few closely spaced buildings: reactor building, turbine hall and so on. As the rule such buildings play sufficiently different roles in NPP operation and therefore have sufficiently different design, natural frequencies (periods) and distortion of floors and different rocking modes on a soil. The main idea explained in the paper is an interconnection of buildings by HVD. Then differences in their mechanical properties provide their out-of-phase relative motions during an earthquake and therefore effective dissipative work provided by HVD devices. At the same time implementation of HVD approach allows to eliminate possible interactions and collisions in the gaps between building structures that wears potential threat of building failure. The detailed 3D finite element models of reactor building, turbine hall and special building were developed for NPP with VVER-1000 MWt reactor type. Performed analysis has shown high efficiency of suggested approach for protection of buildings, structures, systems and components against seismic and other impacts. (authors)

  10. Automated and fast building of three-dimensional RNA structures.

    Science.gov (United States)

    Zhao, Yunjie; Huang, Yangyu; Gong, Zhou; Wang, Yanjie; Man, Jianfen; Xiao, Yi

    2012-01-01

    Building tertiary structures of non-coding RNA is required to understand their functions and design new molecules. Current algorithms of RNA tertiary structure prediction give satisfactory accuracy only for small size and simple topology and many of them need manual manipulation. Here, we present an automated and fast program, 3dRNA, for RNA tertiary structure prediction with reasonable accuracy for RNAs of larger size and complex topology.

  11. Pushover, Response Spectrum and Time History Analyses of Safe Rooms in a Poor Performance Masonry Building

    International Nuclear Information System (INIS)

    Mazloom, M.

    2008-01-01

    The idea of safe room has been developed for decreasing the earthquake casualties in masonry buildings. The information obtained from the previous ground motions occurring in seismic zones expresses the lack of enough safety of these buildings against earthquakes. For this reason, an attempt has been made to create some safe areas inside the existing masonry buildings, which are called safe rooms. The practical method for making these safe areas is to install some prefabricated steel frames in some parts of the existing structure. These frames do not carry any service loads before an earthquake. However, if a devastating earthquake happens and the load bearing walls of the building are destroyed, some parts of the floors, which are in the safe areas, will fall on the roof of the installed frames and the occupants who have sheltered there will survive. This paper presents the performance of these frames located in a destroying three storey masonry building with favorable conclusions. In fact, the experimental pushover diagram of the safe room located at the ground-floor level of this building is compared with the analytical results and it is concluded that pushover analysis is a good method for seismic performance evaluation of safe rooms. For time history analysis the 1940 El Centro, the 2003 Bam, and the 1990 Manjil earthquake records with the maximum peak accelerations of 0.35g were utilized. Also the design spectrum of Iranian Standard No. 2800-05 for the ground kind 2 is used for response spectrum analysis. The results of time history, response spectrum and pushover analyses show that the strength and displacement capacity of the steel frames are adequate to accommodate the distortions generated by seismic loads and aftershocks properly

  12. Effect of Interaction and Rocking Motion on The Earthquake Response of Buildings

    Directory of Open Access Journals (Sweden)

    Gholamreza Havaei

    2015-03-01

    Full Text Available Usually structures are designed under codes based on the assumption that the soil stiffness is infinite, so the foundation rests firmly on the soil. In many cases, the overturning moment due to the lateral forces may exceed the resisting moment due to the gravity forces. Thus, this may cause a foundation uplift because in reality the soil stiffness is not infinite and the structure stands up under gravity forces. The phenomenon of foundation uplifting and its impact on the soil are known as the rocking motion.This study investigates the influence of the rocking motion and interaction by the yielding base plates on the nonlinear behavior of steel structures under dynamic analysis. More specifically, Three- five and seven -storied structuresare designed with ordinary ductility, then the structuresare analyzed in rigid and deformable base plate cases with using the ABAQUS software.The results show that the rocking motion and Interaction decrease the response of buildings such as the base shear, the axial force of columns and the strain energy but also increase the natural period.

  13. Field Experience with and Potential for Multi-time Scale Grid Transactions from Responsive Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Kiliccote, Sila; Ghatikar, Girish

    2014-08-01

    The need for and concepts behind demand response are evolving. As the electric system changes with more intermittent renewable electric supply systems, there is a need to allow buildings to provide more flexible demand. This paper presents results from field studies and pilots, as well as engineering estimates of the potential capabilities of fast load responsiveness in commercial buildings. We present a sector wide analysis of flexible loads in commercial buildings, which was conducted to improve resource planning and determine which loads to evaluate in future demonstrations. These systems provide important capabilities for future transactional systems. The field analysis is based on results from California, plus projects in the northwest and east coast. End-uses considered include heating, ventilation, air conditioning and lighting. The timescales of control include day-ahead, as well as day-of, 10-minute ahead and even faster response. This technology can provide DR signals on different times scales to interact with responsive building loads. We describe the latency of the control systems in the building and the round trip communications with the wholesale grid operators.

  14. Dynamic window daylighting systems: electropolymeric technology for solar responsive building envelopes

    Science.gov (United States)

    Krietemeyer, Elizabeth A.; Smith, Shane I.; Dyson, Anna H.

    2011-04-01

    Human health and energy problems associated with the lack of control of sunlight in contemporary buildings have necessitated research into dynamic windows for energy efficient buildings. Existing window technologies have made moderate progress towards greater energy performance for facades but remain limited in their response to dynamic solar conditions, building energy requirements, and variable user preferences for visual comfort. Recent developments in electropolymeric display technology provide opportunities to transfer electroactive polymers to windows that can achieve high levels of geometric and spectral selectivity through the building envelope in order to meet the lighting, thermal and user requirements of occupied spaces. Experimental simulations that investigate daylight quality, energy performance, and architectural effects of electropolymeric glazing technology are presented.

  15. Coevolutionary and genetic algorithm based building spatial and structural design

    NARCIS (Netherlands)

    Hofmeyer, H.; Davila Delgado, J.M.

    2015-01-01

    In this article, two methods to develop and optimize accompanying building spatial and structural designs are compared. The first, a coevolutionary method, applies deterministic procedures, inspired by realistic design processes, to cyclically add a suitable structural design to the input of a

  16. A case study on the structural assessment of fire damaged building

    Science.gov (United States)

    Osman, M. H.; Sarbini, N. N.; Ibrahim, I. S.; Ma, C. K.; Ismail, M.; Mohd, M. F.

    2017-11-01

    This paper presents a case study on the structural assessment of building damaged by fire and discussed on the site investigations and test results prior to determine the existing condition of the building. The building was on fire for about one hour before it was extinguished. In order to ascertain the integrity of the building, a visual inspection was conducted for all elements (truss, beam, column and wall), followed by non-destructive, load and material tests. The load test was conducted to determine the ability of truss to resist service load, while the material test to determine the residual strength of the material. At the end of the investigation, a structural analysis was carried out to determine the new factor of safety by considering the residual strength. The highlighted was on the truss element due to steel behaviour that is hardly been predicted. Meanwhile, reinforced concrete elements (beam, column and wall) were found externally affected and caused its strength to be considered as sufficient for further used of building. The new factor of safety is equal to 2, considered as the minimum calculated value for the truss member. Therefore, this fire damaged building was found safe and can be used for further application.

  17. Integrating Environmentally Responsive Elements in Buildings

    DEFF Research Database (Denmark)

    Heiselberg, Per

    2006-01-01

    Significant improvement have been achieved on efficiency improvements of specific building elements like the building envelope and building equipment and services and whilst most building elements still offer opportunities for efficiency improvements, the greatest future potential lie with techno......Significant improvement have been achieved on efficiency improvements of specific building elements like the building envelope and building equipment and services and whilst most building elements still offer opportunities for efficiency improvements, the greatest future potential lie...

  18. Seismic analysis of a reactor building with eccentric layout

    International Nuclear Information System (INIS)

    Itoh, T.; Deng, D.Z.F.; Lui, K.

    1987-01-01

    Conventional design for a reactor building in a high seismic area has adopted an essentially concentric layout in response to fear of excessive torsional effect due to horizontal seismic load on an eccentric plant. This concentric layout requirement generally results in an inflexible arrangement of the plant facilities and thus increases the plant volume. This study is performed to investigate the effect of eccentricity on the overall seismic structural response and to provide technical information in this regard to substantiate the volume reduction of the overall power plant. The plant layout is evolved from the Bechtel standard plan of a PWR plant by integrating the reactor building and the auxiliary building into a combined building supported on a common basemat. This plant layout is optimized for volume utilization and to reduce the length of piping systems. The mass centers at various elevations of the combined building do not coincide with the rigidity center (RC) of the respective floor and the geometric center of the basemat, thus creating an eccentric response of the building in a seismic environment. Therefore, the torsional effects of the structure have to be taken into account in the seismic analysis

  19. Trends in the structures development of the regional machine-building complex

    Directory of Open Access Journals (Sweden)

    Ershova I.V.

    2017-01-01

    Full Text Available In the process of market reforms of the Russian machine-building complex several distinct periods can be revealed. In this article the authors define periods of mass disintegration and spontaneous integration (since the beginning of the reforms until the financial crisis of 1996, post-crisis stabilization, directional specialization (2000-2008 and evolutionary development (since 2010. The economic consequences of the enterprises mergers and divisions are shown on the example of machine-building enterprises of the Middle Urals. The aim of this study is to substantiate the methodical approach to the selection of the optimal organizational structure for the machine-building business. The necessity of taking into account the extent of the personnel diversification and the production volume has been revealed for the optimum organizational structure determination in the machine-building associations. The authors have analyzed sales profitability of the 2745 machine-building enterprises, depending on the production scale and industry sector. The factors affecting the development of cooperative ties and outsourcing have been defined. The authors have made a conclusion that it is necessary to form technological chains as a new kind of business associations.

  20. Automatic Generation of Structural Building Descriptions from 3D Point Cloud Scans

    DEFF Research Database (Denmark)

    Ochmann, Sebastian; Vock, Richard; Wessel, Raoul

    2013-01-01

    We present a new method for automatic semantic structuring of 3D point clouds representing buildings. In contrast to existing approaches which either target the outside appearance like the facade structure or rather low-level geometric structures, we focus on the building’s interior using indoor...... scans to derive high-level architectural entities like rooms and doors. Starting with a registered 3D point cloud, we probabilistically model the affiliation of each measured point to a certain room in the building. We solve the resulting clustering problem using an iterative algorithm that relies...

  1. The Building of a Responsible Research Community: The Role of Ethics

    Science.gov (United States)

    Lategan, Laetus O. K.

    2012-01-01

    This paper looks into the importance of a responsible research community and how ethics can contribute towards the building of such a community. The paper starts off by outlining the many challenges facing a responsible research community. These challenges range from doing research, transferring the research results, commercialising the…

  2. Earthquake response analysis of embedded reactor building considering soil-structure separation and nonlinearity of soil

    International Nuclear Information System (INIS)

    Ichikawa, T.; Hayashi, Y.; Nakai, S.

    1987-01-01

    The effect of the wall-ground separation depends on the relation between the fundamental frequency of the SSI system and that of the surface layer. The maximum accelerations of the upper floors are increased if the side soil is soft. The building shear force is decreased below the ground level if the fundamental frequency of the SSI system is nearly equal to that of the surface layer. The floor response spectra are slightly increased in the high frequency range. Yielding of the soil occurred only in case that the side soil is soft, and the yield zone was restricted in the upper part of the surface layer. Therefore, the material nonlinearity did not affect the results so much. The results of the sway-rocking model (lumped mass model) analysis showed good agreements with those of the FEM models. (orig./HP)

  3. Hydraulic behaviour of a representative structural volume for containment buildings

    International Nuclear Information System (INIS)

    Jason, Ludovic; Pijaudier-Cabot, Gilles; Ghavamian, Shahrokh; Huerta, Antonio

    2007-01-01

    For particular structures like containment buildings of nuclear power plants, the study of the hydraulic behaviour is of great concern. These structures are indeed the third barrier used to protect the environment in case of accidents. The evolution of the leaking rate through the porous medium is closely related to the changes in the permeability during the ageing process of the structure. It is thus essential to know the relation between concrete degradation and the transfer property when the consequences of a mechanical loading on the hydraulic behaviour have to be evaluated. A chained approach is designed for this purpose. The mechanical behaviour is described by an elastic plastic damage formulation, where damage is responsible for the softening evolution while plasticity accounts for the development of irreversible strains. The drying process is evaluated according to a non-linear equation of diffusion. From the knowledge of the damage and the degree of saturation, a relation is proposed to calculate the permeability of concrete. Finally, the non-homogeneous distribution of the hydraulic conductivity is included in the hydraulic problem which is in fact the association of the mass balance equation for gas phase and Darcy law. From this methodology, it is shown how an indicator for the hydraulic flows can be deduced

  4. Building Integrated Active Flow Control: Improving the Aerodynamic Performance of Tall Buildings Using Fluid-Based Aerodynamic Modification

    Science.gov (United States)

    Menicovich, David

    material and energy consumption profiles of tall building. To date, the increasing use of light-weight and high-strength materials in tall buildings, with greater flexibility and reduced damping, has increased susceptibility to dynamic wind load effects that limit the gains afforded by incorporating these new materials. Wind, particularly fluctuating wind and its interaction with buildings induces two main responses; alongwind - in the direction of the flow and crosswind - perpendicular to the flow. The main risk associated with this vulnerability is resonant oscillations induced by von-Karman-like vortex shedding at or near the natural frequency of the structure caused by flow separation. Dynamic wind loading effects often increase with a power of wind speed greater than 3, thus increasingly, tall buildings pay a significant price in material to increase the natural frequency and/or the damping to overcome this response. In particular, crosswind response often governs serviceability (human habitability) design criteria of slender buildings. Currently, reducing crosswind response relies on a Solid-based Aerodynamic Modification (SAM), either by changing structural or geometric characteristics such as the tower shape or through the addition of damping systems. While this approach has merit it has two major drawbacks: firstly, the loss of valuable rentable areas and high construction costs due to increased structural requirements for mass and stiffness, further contributing towards the high consumption of non-renewable resources by the commercial building sector. For example, in order to insure human comfort within an acceptable range of crosswind response induced accelerations at the top of a building, an aerodynamically efficient plan shape comes at the expense of floor area. To compensate for the loss of valuable area compensatory stories are required, resulting in an increase in wind loads and construction costs. Secondly, a limited, if at all, ability to adaptively

  5. PS buildings : reinforced concrete structure for shielding "bridge" pillar

    CERN Multimedia

    CERN PhotoLab

    1956-01-01

    The PS ring traverses the region between the experimental halls South and North (buildings Nos 150 and 151) under massive bridge-shaped concrete beams. This pillar stands at the S-W end of the structure.

  6. Green Building Premium Cost Analysis in Indonesia Using Work Breakdown Structure Method

    Science.gov (United States)

    Basten, V.; Latief, Y.; Berawi, M. A.; Riswanto; Muliarto, H.

    2018-03-01

    The concept of green building in the construction industry is indispensable for mitigating environmental issues such as waste, pollution, and carbon emissions. There are some countries that have Green Building rating tools. Indonesia particularly is the country which has Greenship rating tools but the number of Green Building is relatively low. Development of building construction is depended on building investors or owner initiation, so this research is conducted to get the building aspects that have significant effect on the attractiveness using The Green Building Concept. The method in this research is work breakdown structure method that detailing the green building activities. The particular activities will be processed to get the cost elements for the green building achievement that it was targeted to improve better than conventional building. The final result of the study was a very significant work package on green building construction in the city of Indonesia case study.

  7. Evaluation of soil-structure interaction for structures subjected to earthquake loading with different types of foundation

    Directory of Open Access Journals (Sweden)

    Elwi Mohammed

    2018-01-01

    Full Text Available However though the structures are supported on soil, most of the designers do not consider the soil structure interaction and its subsequent effect on structure during an earthquake. Different soil properties can affect seismic waves as they pass through a soil layer. When a structure is subjected to an earthquake excitation, it interacts the foundation and soil, and thus changes the motion of the ground. It means that the movement of the whole ground structure system is influenced by type of soil as well as by the type of structure. Tall buildings are supposed to be of engineered construction in sense that they might have been analyzed and designed to meet the provision of relevant codes of practice and building bye-laws. IS 1893: 2002 “Criteria for Earthquake Resistant Design of Structures” gives response spectrum for different types of soil such as hard, medium and soft. An attempt has been made in this paper to study the effect of Soil-structure interaction on multi storeyed buildings with various foundation systems. Also to study the response of buildings subjected to seismic forces with Rigid and Flexible foundations. Multi storeyed buildings with fixed and flexible support subjected to seismic forces were analyzed under different soil conditions like hard, medium and soft. The buildings were analyzed by Response spectrum method using software SAP2000. The response of building frames such as Lateral deflection, Story drift, Base shear, Axial force and Column moment values for all building frames were presented in this paper.

  8. DESIGN PROBLEMS OF THE BUILDINGS FOUNDATIONS AND STRUCTURES CONSTRUCTED IN DENSE URBAN AREAS

    OpenAIRE

    O. Yu. Prokopov; M. V. Prokopova

    2007-01-01

    The urgency of methodical provision of planning of foundations for buildings erected next to existing ones is сonsidered. It is based on studying the causes of extension of deformations of structures in conditions of dense city building system. Some recommendations providing safety of buildings are given.

  9. Forced vibration tests and simulation analyses of a nuclear reactor building. Part 2: simulation analyses

    International Nuclear Information System (INIS)

    Kuno, M.; Nakagawa, S.; Momma, T.; Naito, Y.; Niwa, M.; Motohashi, S.

    1995-01-01

    Forced vibration tests of a BWR-type reactor building. Hamaoka Unit 4, were performed. Valuable data on the dynamic characteristics of the soil-structure interaction system were obtained through the tests. Simulation analyses of the fundamental dynamic characteristics of the soil-structure system were conducted, using a basic lumped mass soil-structure model (lattice model), and strong correlation with the measured data was obtained. Furthermore, detailed simulation models were employed to investigate the effects of simultaneously induced vertical response and response of the adjacent turbine building on the lateral response of the reactor building. (author). 4 refs., 11 figs

  10. Building Fire Safety Audit at Faculty X, University of Indonesia, Year 2006

    Directory of Open Access Journals (Sweden)

    Fatma Lestari

    2010-10-01

    Full Text Available Fire may cause loss of life, material and valuable assets. The objective of this study is to conduct audit for fire safety and emergency response in the building at Faculty X, University of Indonesia, Depok. The audit results on the building fire safety facilities including emergency response and preparedness are then compared to the Building Code Australia (BCA and Indonesian regulation on the building fire safety (Kep.MenPU.No 10 and 11/KPTS/2000. The building selected are Building A, B, C, D, F and G. Building classification for A, B, D, F and G are classified as Class 5, while Building C is classified as Class 9b. Variable which are evaluated including emergency exit, building structure, fire alarm and detector, communication and fire warning system, evacuation procedure, portable fire extinguishers, hydrant, sprinkler, and emergency response preparedness. Results suggested that emergency exit is locked, and this is not comply to the regulation. Building structure has been complied to the regulation since it was made of concrete. Fire detector and alarm only provided in Building G, while other building is not available. There is no evacuation procedure available. Portable fire extinguisher has been available in all the building. Hydrant an sprinkler only available in building G. There is no emergency response preparedness in this faculty. In conclusion, the fire safety facilities in this faculty need to be improved.

  11. Effects of soil stiffness and embedment on reactor building response

    International Nuclear Information System (INIS)

    Michalopoulos, A.P.; Vardanega, C.; Cornaggia, L.

    1981-01-01

    A parametric study was made to assess the influence of soil conditions and foundation embedment depth on the floor response spectra for a reactor building. The analyses incorporated soft, medium and hard soils, and three different embedment depths, in a seismic environment described by a 0.36 g peak ground acceleration. The shear wave velocity profiles for the soft, medium and hard soil conditions, were assumed to increase in proportion to the square root of depth from their ground surface values of 300, 600 and 900 meters per second, respectively. Foundation embedment depths of zero, eight and fourteen meters were analyzed using elastic half-space theory, accounting for kinematic interaction. The variation of shear modulus with depth under earthquake excitation was determined using a deconvolution process. Horizontal and vertical synthetic time histories, matching the USNRC Regulatory Guide 1.60 design ground response spectra, were applied at the ground surface and then deconvolved to the foundation level to obtain the input for the soil-structure model. The mathematical model of the superstructure consisted of four lumped-mass close-coupled systems, representing containment shells and components, while the foundation mat was modeled as rigid. Lumped soil compliances (springs and dashpots) were used to represent the horizontal, vertical and rotational modes of vibration. The dynamic analyses were performed utilizing the computer code DAPSYS, and consisted of mode frequency analyses and modal superposition. Modal damping was computed as a weighted average of structural and soil (radiation and material) damping, using the strain energy stored in the respective components as the weighting factor and distinguishing the hysteric nature of the structural and soil material damping, and the viscous nature of the soil radiation damping. (orig./RW)

  12. Network Structure, Diversity, and Proactive Resilience Building: a Response to Tompkins and Adger

    Directory of Open Access Journals (Sweden)

    Lenore Newman

    2005-06-01

    Full Text Available Although community social networks can build resilience, and thus, aid adaptation to unexpected environmental change (Tomkins and Adger 2004, not all social networks are created equal. Networks composed of a diversity of "bridging" links to a diverse web of resources and "bonding" links that build trust strengthen a community's ability to adapt to change, but networks composed only of "bonding" links can impose constraining social norms and foster group homophily, reducing resilience. Diversity fosters the resilience needed to adapt to unexpected change, and can also enlarge the ability to proactively make collective decisions that optimize future options.

  13. Floor Response Spectra of a Base Isolated Auxiliary Building in Different Temperature Environments

    International Nuclear Information System (INIS)

    Park, Junhee; Choun, Youngsun; Choi, Inkil

    2013-01-01

    It is necessary to investigate the aging effect of degradation factors and to evaluate the seismic response of base isolated NPPs with age-related degradation. In this study, the seismic responses for NPPs using high damping rubber bearing with age-related degradation in different temperature were investigated by performing a nonlinear time history analysis. The floor response spectrums (FRS) were presented with time in different temperature environments. The degradation of HRB is found to be particularly sensitive to the ambient temperature. The increase of HRB stiffness leads to the increase of FRS it was observed that the seismic demand for equipment located in the AUX was changed. Therefore it is required that the seismic evaluation for the isolation system (e. g. isolators, equipment located in isolated structure) is performed considering the temperature environments. From the seismic fragility analysis, the seismic capacity of cabinet was affected by the degradation of HRB. Therefore the isolators in the isolated buildings should be carefully designed and manufactured considering the degradation during the life time

  14. DESIGN PROBLEMS OF THE BUILDINGS FOUNDATIONS AND STRUCTURES CONSTRUCTED IN DENSE URBAN AREAS

    Directory of Open Access Journals (Sweden)

    O. Yu. Prokopov

    2007-10-01

    Full Text Available The urgency of methodical provision of planning of foundations for buildings erected next to existing ones is сonsidered. It is based on studying the causes of extension of deformations of structures in conditions of dense city building system. Some recommendations providing safety of buildings are given.

  15. Salt Damage and Rising Damp Treatment in Building Structures

    Directory of Open Access Journals (Sweden)

    J. M. P. Q. Delgado

    2016-01-01

    Full Text Available Salt damage can affect the service life of numerous building structures, both historical and contemporary, in a significant way. In this review, various damage mechanisms to porous building materials induced by salt action are analyzed. The importance of pretreatment investigations is discussed as well; in combination with the knowledge of salt and moisture transport mechanisms they can give useful indications regarding treatment options. The methods of salt damage treatment are assessed then, including both passive techniques based on environmental control, reduction of water transport, or conversion to less soluble salts and active procedures resulting in the removal of salts from deterioration zones. It is concluded that cellulose can still be considered as the favorite material presently used in desalination poultices but hydrophilic mineral wool can serve as its prospective alternative in future applications. Another important cause of building pathologies is the rising damp and, in this phenomenon, it is particularly severe considering the presence of salts in water. The treatment of rising damp in historic building walls is a very complex procedure and at Laboratory of Building Physics (LFC-FEUP a wall base hygroregulated ventilation system was developed and patented.

  16. Toward Accessing Spatial Structure from Building Information Models

    Science.gov (United States)

    Schultz, C.; Bhatt, M.

    2011-08-01

    Data about building designs and layouts is becoming increasingly more readily available. In the near future, service personal (such as maintenance staff or emergency rescue workers) arriving at a building site will have immediate real-time access to enormous amounts of data relating to structural properties, utilities, materials, temperature, and so on. The critical problem for users is the taxing and error prone task of interpreting such a large body of facts in order to extract salient information. This is necessary for comprehending a situation and deciding on a plan of action, and is a particularly serious issue in time-critical and safety-critical activities such as firefighting. Current unifying building models such as the Industry Foundation Classes (IFC), while being comprehensive, do not directly provide data structures that focus on spatial reasoning and spatial modalities that are required for high-level analytical tasks. The aim of the research presented in this paper is to provide computational tools for higher level querying and reasoning that shift the cognitive burden of dealing with enormous amounts of data away from the user. The user can then spend more energy and time in planning and decision making in order to accomplish the tasks at hand. We present an overview of our framework that provides users with an enhanced model of "built-up space". In order to test our approach using realistic design data (in terms of both scale and the nature of the building models) we describe how our system interfaces with IFC, and we conduct timing experiments to determine the practicality of our approach. We discuss general computational approaches for deriving higher-level spatial modalities by focusing on the example of route graphs. Finally, we present a firefighting scenario with alternative route graphs to motivate the application of our framework.

  17. Experimental and analytical studies on soil-structure interaction behavior of nuclear reactor building

    International Nuclear Information System (INIS)

    Tsushima, Y.

    1978-01-01

    The purpose of this study is to estimate damping effects due to soil-structure interaction by the dissipation of vibrational energy to the ground through the foundation in a building with a short fundamental period such as a nuclear reactor building. The author performed experimental and analytical studies on the vibrational characteristics of model steel structures ranging from one to four stories high erected on the rigid base and located on soil, which are simulated from the vibrational characteristics of a prototype reactor building: the former study is to obtain damping effects due to inner friction of steel frames and the latter to obtain radiation damping effects due to soil-structure interaction. The author also touches upon the results of experiments performed on a BWR-type reactor building in 1974, which showed damping ratios higher than 20% of those in fundamental modes. Then the author attempts to estimate the damping effects of the reactor building by his own method proposed in the report. Through these studies the author finally concludes that the experimental damping effects are remarkable in the lower modes by the energy dissipation and the analytical results show a fairly good fit to the experimental ones

  18. Seismic response analysis of Wolsung NPP structure and equipment subjected to scenario earthquakes

    Energy Technology Data Exchange (ETDEWEB)

    Choi, In Kil; Ahn, Seong Moon; Choun, Young Sun; Seo, Jeong Moon

    2005-03-15

    The standard response spectrum proposed by US NRC has been used as a design earthquake for the design of Korean nuclear power plant structures. However, it does not reflect the characteristic of seismological and geological of Korea. In this study, the seismic response analysis of Wolsung NPP structure and equipment were performed. Three types of input motions, artificial time histories that envelop the US NRC Regulatory Guide 1.60 spectrum and the probability based scenario earthquake spectra developed for the Korean NPP site and a typical near-fault earthquake recorded at thirty sites, were used as input motions. The acceleration, displacement and shear force responses of Wolsung containment structure due to the design earthquake were larger than those due to the other input earthquakes. But, considering displacement response increases abruptly as Wolsung NPP structure does nonlinear behavior, the reassessment of the seismic safety margin based on the displacement is necessary if the structure does nonlinear behavior; although it has adequate the seismic safety margin within elastic limit. Among the main safety-related devices, electrical cabinet and pump showed the large responses on the scenario earthquake which has the high frequency characteristic. This has great effects of the seismic capacity of the main devices installed inside of the building. This means that the design earthquake is not so conservative for the safety of the safety related nuclear power plant equipments.

  19. Seismic response analysis of Wolsung NPP structure and equipment subjected to scenario earthquakes

    International Nuclear Information System (INIS)

    Choi, In Kil; Ahn, Seong Moon; Choun, Young Sun; Seo, Jeong Moon

    2005-03-01

    The standard response spectrum proposed by US NRC has been used as a design earthquake for the design of Korean nuclear power plant structures. However, it does not reflect the characteristic of seismological and geological of Korea. In this study, the seismic response analysis of Wolsung NPP structure and equipment were performed. Three types of input motions, artificial time histories that envelop the US NRC Regulatory Guide 1.60 spectrum and the probability based scenario earthquake spectra developed for the Korean NPP site and a typical near-fault earthquake recorded at thirty sites, were used as input motions. The acceleration, displacement and shear force responses of Wolsung containment structure due to the design earthquake were larger than those due to the other input earthquakes. But, considering displacement response increases abruptly as Wolsung NPP structure does nonlinear behavior, the reassessment of the seismic safety margin based on the displacement is necessary if the structure does nonlinear behavior; although it has adequate the seismic safety margin within elastic limit. Among the main safety-related devices, electrical cabinet and pump showed the large responses on the scenario earthquake which has the high frequency characteristic. This has great effects of the seismic capacity of the main devices installed inside of the building. This means that the design earthquake is not so conservative for the safety of the safety related nuclear power plant equipments

  20. Study on the Seismic Response of a Portal Frame Structure Based on the Transfer Matrix Method of Multibody System

    Directory of Open Access Journals (Sweden)

    Jianguo Ding

    2014-11-01

    Full Text Available Portal frame structures are widely used in industrial building design but unfortunately are often damaged during an earthquake. As a result, a study on the seismic response of this type of structure is important to both human safety and future building designs. Traditionally, finite element methods such as the ANSYS and MIDAS have been used as the primary methods of computing the response of such a structure during an earthquake; however, these methods yield low calculation efficiencies. In this paper, the mechanical model of a single-story portal frame structure with two spans is constructed based on the transfer matrix method of multibody system (MS-TMM; both the transfer matrix of the components in the model and the total transfer matrix equation of the structure are derived, and the corresponding MATLAB program is compiled to determine the natural period and seismic response of the structure. The results show that the results based on the MS-TMM are similar to those obtained by ANSYS, but the calculation time of the MS-TMM method is only 1/20 of that of the ANSYS method. Additionally, it is shown that the MS-TMM method greatly increases the calculation efficiency while maintaining accuracy.

  1. ANALYSIS OF SUFFICIENCY OF THE BEARING CAPACITY OF BUILDING STRUCTURES OF OPERATING SITES OF MAIN BUILDINGS OF THERMAL POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Alekseeva Ekaterina Leonidovna

    2012-10-01

    Full Text Available Upon examination of eleven main buildings of power plants, analysis of defects and damages of building structures was performed. Thereafter, the damageability of principal bearing structures of main buildings of thermal plants was analyzed. It was identified that the fastest growing defects and damages were concentrated in the structures of operating sites. The research of the rate of development of the most frequent damages and defects made it possible to conclude that internal corrosion of the reinforcing steel was the most dangerous defect, as far as the reinforced concrete elements of operating sites were concerned. Methods of mathematical statistics were applied to identify the reinforcing steel development pattern inside reinforced concrete elements of floors of operating sites. It was identified that the probability of corrosion of reinforced concrete elements of operating sites was distributed in accordance with the demonstrative law. Based on these data, calculation of strength of reinforced concrete slabs and metal beams was performed in terms of their regular sections, given the natural loads and the realistic condition of structures. As a result, dependence between the bearing capacity reserve ratio and the corrosion development pattern was identified for reinforced concrete slabs and metal beams of operating sites. In order to analyze the sufficiency of the bearing capacity of building structures of operating sites in relation to their time in commission, equations were derived to identify the nature of dependence between the sufficiency of the bearing capacity of reinforced concrete slabs and metal beams of the operating sites and their time in commission.

  2. Design automation of load-bearing arched structures of roofs of tall buildings

    Science.gov (United States)

    Kulikov, Vladimir

    2018-03-01

    The article considers aspects of the possible use of arched roofs in the construction of skyscrapers. Tall buildings experience large load from various environmental factors. Skyscrapers are subject to various and complex types of deformation of its structural elements. The paper discusses issues related to the aerodynamics of various structural elements of tall buildings. The technique of solving systems of equations state method of Simpson. The article describes the optimization of geometric parameters of bearing elements of the arched roofs of skyscrapers.

  3. Direct Georeferencing of Uav Data Based on Simple Building Structures

    Science.gov (United States)

    Tampubolon, W.; Reinhardt, W.

    2016-06-01

    Unmanned Aerial Vehicle (UAV) data acquisition is more flexible compared with the more complex traditional airborne data acquisition. This advantage puts UAV platforms in a position as an alternative acquisition method in many applications including Large Scale Topographical Mapping (LSTM). LSTM, i.e. larger or equal than 1:10.000 map scale, is one of a number of prominent priority tasks to be solved in an accelerated way especially in third world developing countries such as Indonesia. As one component of fundamental geospatial data sets, large scale topographical maps are mandatory in order to enable detailed spatial planning. However, the accuracy of the products derived from the UAV data are normally not sufficient for LSTM as it needs robust georeferencing, which requires additional costly efforts such as the incorporation of sophisticated GPS Inertial Navigation System (INS) or Inertial Measurement Unit (IMU) on the platform and/or Ground Control Point (GCP) data on the ground. To reduce the costs and the weight on the UAV alternative solutions have to be found. This paper outlines a direct georeferencing method of UAV data by providing image orientation parameters derived from simple building structures and presents results of an investigation on the achievable results in a LSTM application. In this case, the image orientation determination has been performed through sequential images without any input from INS/IMU equipment. The simple building structures play a significant role in such a way that geometrical characteristics have been considered. Some instances are the orthogonality of the building's wall/rooftop and the local knowledge of the building orientation in the field. In addition, we want to include the Structure from Motion (SfM) approach in order to reduce the number of required GCPs especially for the absolute orientation purpose. The SfM technique applied to the UAV data and simple building structures additionally presents an effective tool

  4. SEISMIC EVALUATION OF EXISTING MID-RISE REINFORCED CONCRETE BUILDINGS ACCORDING TO SPECIFICATION FOR BUILDING STRUCTURES TO BE BUILT IN DISASTER AREAS

    Directory of Open Access Journals (Sweden)

    Mehmet İNEL

    2007-01-01

    Full Text Available Over the past several decades, Turkey has been hit by devastating earthquakes and remarkable number of reinforced concrete buildings has been damaged in the high seismicity regions of our country. The aim of this study is to evaluate the seismic performance of the mid-rise reinforced concrete buildings that are major part of building stock of our earthquake-prone country, according to recent Turkish Earthquake Code. 4- and 7-story buildings were selected to represent mid-rise building stock. After determining the structural parameters, each building was subjected to pushover analysis and the capacity curves were obtained. Earthquake performance of each building was determined in the light of their capacity curves according to the recent Turkish Earthquake Code.

  5. A simple method for estimating thermal response of building ...

    African Journals Online (AJOL)

    This paper develops a simple method for estimating the thermal response of building materials in the tropical climatic zone using the basic heat equation. The efficacy of the developed model has been tested with data from three West African cities, namely Kano (lat. 12.1 ºN) Nigeria, Ibadan (lat. 7.4 ºN) Nigeria and Cotonou ...

  6. Seismic response analysis of BWR buildings with embedded foundation

    International Nuclear Information System (INIS)

    Fukuzawa, R.; Chiba, O.; Tohdo, M.

    1985-01-01

    An investigation on the effect of various types of foundations embedded into soil deposit to the responses of BWR buildings is made. The frequency characteristics of massless rigid foundations such as impedance functions and input motion are first obtained, depending on the embedment depth, contact condition of side wall to soil and the thickness of surface layer in a two-layered soil. From the results it is found that the embedment depth and the thickness of surface layer have a distinct effect to the responses contributed by the impedance functions and the response values characterized by the input motions are obviously influenced by the embedment depth and the contact length of side wall to soil deposit. (orig.)

  7. On the design of high-rise buildings with a specified level of reliability

    Science.gov (United States)

    Dolganov, Andrey; Kagan, Pavel

    2018-03-01

    High-rise buildings have a specificity, which significantly distinguishes them from traditional buildings of high-rise and multi-storey buildings. Steel structures in high-rise buildings are advisable to be used in earthquake-proof regions, since steel, due to its plasticity, provides damping of the kinetic energy of seismic impacts. These aspects should be taken into account when choosing a structural scheme of a high-rise building and designing load-bearing structures. Currently, modern regulatory documents do not quantify the reliability of structures. Although the problem of assigning an optimal level of reliability has existed for a long time. The article shows the possibility of designing metal structures of high-rise buildings with specified reliability. Currently, modern regulatory documents do not quantify the reliability of high-rise buildings. Although the problem of assigning an optimal level of reliability has existed for a long time. It is proposed to establish the value of reliability 0.99865 (3σ) for constructions of buildings and structures of a normal level of responsibility in calculations for the first group of limiting states. For increased (construction of high-rise buildings) and reduced levels of responsibility for the provision of load-bearing capacity, it is proposed to assign respectively 0.99997 (4σ) and 0.97725 (2σ). The coefficients of the use of the cross section of a metal beam for different levels of security are given.

  8. Analysis, Design, and Construction of a Base-Isolated Multiple Building Structure

    Directory of Open Access Journals (Sweden)

    Stefano Sorace

    2014-01-01

    Full Text Available The analysis and design of a multiple residential building, seismically protected by a base isolation system incorporating double friction pendulum sliders as protective devices, are presented in the paper. The building, situated in the suburban area of Florence, is composed of four independent reinforced concrete framed structures, mutually separated by three thermal expansion joints. The plan is L-shaped, with dimensions of about 75 m in the longitudinal direction and about 30 m along the longest side of the transversal direction. These characteristics identify the structure as the largest example of a base-isolated “artificial ground” ever built in Italy. The base isolation solution guarantees lower costs, a much greater performance, and a finer architectural look, as compared to a conventional fixed-base antiseismic design. The characteristics of the building and the isolators, the mechanical properties and the experimental characterization campaign and preliminary sizing carried out on the latter, and the nonlinear time-history design and performance assessment analyses developed on the base isolated building are reported in this paper, along with details about the installation of the isolators and the plants and highlights of the construction works.

  9. Direct Linear System Identification Method for Multistory Three-dimensional Building Structure with General Eccentricity

    OpenAIRE

    Shintani, Kenichirou; Yoshitomi, Shinta; Takewaki, Izuru

    2017-01-01

    A method of physical parameter system identification (SI) is proposed here for three-dimensional (3D) building structures with in-plane rigid floors in which the stiffness and damping coefficients of each structural frame in the 3D building structure are identified from the measured floor horizontal accelerations. A batch processing least-squares estimation method for many discrete time domain measured data is proposed for the direct identification of the stiffness and damping coefficients of...

  10. Hybrid Control System for Greater Resilience Using Multiple Isolation and Building Connection

    Directory of Open Access Journals (Sweden)

    Masaki Taniguchi

    2016-10-01

    Full Text Available An innovative hybrid control building system of multiple isolation and connection is proposed and investigated using both time-history and input energy responses for various types of ground motions together with transfer functions. It is concerned that the seismic displacement response at the base-isolation layer of the existing base-isolated buildings may extremely increase under long-period and long-duration ground motions which are getting great attention recently. In order to enhance the seismic performance of those base-isolated buildings, a novel hybrid system of multiple isolation and building-connection is proposed and compared with other structural systems such as an independent multiple isolation system, a hybrid system of base-isolation and building-connection. Furthermore, the robustness of seismic responses of the proposed hybrid system for various types of ground motion is discussed through the comparison of various structural systems including non-hybrid systems. Finally the optimal connection damper location is investigated using a sensitivity-type optimization approach.

  11. Automatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection

    Directory of Open Access Journals (Sweden)

    M. Kasagi

    2016-02-01

    Full Text Available A base-isolated building may sometimes exhibit an undesirable large response to a long-duration, long-period earthquake ground motion and a connected building system without base-isolation may show a large response to a near-fault (rather high-frequency earthquake ground motion. To overcome both deficiencies, a new hybrid control system of base-isolation and building-connection is proposed and investigated. In this new hybrid building system, a base-isolated building is connected to a stiffer free wall with oil dampers. It has been demonstrated in a preliminary research that the proposed hybrid system is effective both for near-fault (rather high-frequency and long-duration, long-period earthquake ground motions and has sufficient redundancy and robustness for a broad range of earthquake ground motions.An automatic generation algorithm of this kind of smart structures of base-isolation and building-connection hybrid systems is presented in this paper. It is shown that, while the proposed algorithm does not work well in a building without the connecting-damper system, it works well in the proposed smart hybrid system with the connecting damper system.

  12. MODERN BUILDING STRUCTURES USED FOR MILITARY PURPOSES

    Directory of Open Access Journals (Sweden)

    Mariana Domnica STANCIU

    2014-04-01

    Full Text Available This paper investigates the technical aspects of the spherical spatial structures, focusing on the tensegrity building systems used for military purpose. The spherical spatial structures have been studied and used since antiquity. Pythagoras, Plato and Euclid were conducted extensive research on the concept of such type of structures. Regular pentagon has properties related to the value of the golden section, intuitively used by great architects and engineers since ancient times. In the Middle Ages, Leonardo Da Vinci created spatial objects using proportions based on the golden number, and later R. B. Fuller made the famous geodesic domes. The structures proposed by the authors are based on concepts related to the "golden section", on studies made on the regular pentagon, on the spatial volumes able to be inscribed in spheres and on the tensegrity systems. The proposed structures present some advantages related to the ease of mounting, to the volume covered, to the resistance to the environmental factors (snow, wind, earthquake, and so on. The paper presents the conclusions of the investigations on the components of the spatial structures and on the outcomes of their use.

  13. USAGE OF CONSTRUCTION-ORIENTED SOFTWARE SCAD FOR ANALYSIS OF WORK OF MACHINE-BUILDING STRUCTURES

    Directory of Open Access Journals (Sweden)

    D. О. Bannikov

    2018-02-01

    Full Text Available Purpose. In the case of analysis of work of the machine-building structures, the direct usage of construction-oriented software developments is impossible, since ideology and methodology for solving various tasks in construction and machine-building are different. Therefore, in the conducting of practical calculations, there is a need for a certain adjustment of the approaches put in the program complexes and their adaptation to the engineering industry. The presentation of the author's experience of the construction-oriented software SCAD usage for Windows for analyzing the work of various machine-building structures, their components and assemblies is the immediate purpose of the publication. Methodology. During a long period of time the author was engaged in analyzing the work of building, mainly thin-walled, steel structures using the Finite Element Method based on the SCAD for Windows software package. At the same time, a considerable number of machine-building structures were considered, including railroad rolling stock units. Most of these tasks grew into a scientific and research problem that needed to be thoroughly researched and analyzed before giving design recommendations. Findings. The publication presents more than a dozen different tasks, typical for the machine-building industry, which the author had to deal with. Static and quasi-static problems, the problem of motion in time, the contact problem, the problem of the cracks deve-lopment, the physical and geometric non-linearity are among them. Accordingly, for each of these problems the main challenges, features and practical techniques developed during the work are presented, as well as the constructed finite element models are presented as an illustration. Originality. The experience of construction-oriented software product usage on the basis of the Finite Element Method for analyzing of the work of machine-building structures is generalized. A number of practical methods and

  14. Seismic simulation analysis of nuclear reactor building by soil-building interaction model

    International Nuclear Information System (INIS)

    Muto, K.; Kobayashi, T.; Motohashi, S.; Kusano, N.; Mizuno, N.; Sugiyama, N.

    1981-01-01

    Seismic simulation analysis were performed for evaluating soil-structure interaction effects by an analytical approach using a 'Lattice Model' developed by the authors. The purpose of this paper is to check the adequacy of this procedure for analyzing soil-structure interaction by means of comparing computed results with recorded ones. The 'Lattice Model' approach employs a lumped mass interactive model, in which not only the structure but also the underlying and/or surrounding soil are modeled as descretized elements. The analytical model used for this study extends about 310 m in the horizontal direction and about 103 m in depth. The reactor building is modeled as three shearing-bending sticks (outer wall, inner wall and shield wall) and the underlying and surrounding soil are divided into four shearing sticks (column directly beneath the reactor building, adjacent, near and distant columns). A corresponding input base motion for the 'Lattice Model' was determined by a deconvolution analysis using a recorded motion at elevation -18.5 m in the free-field. The results of this simulation analysis were shown to be in reasonably good agreement with the recorded ones in the forms of the distribution of ground motions and structural responses, acceleration time histories and related response spectra. These results showed that the 'Lattice Model' approach was an appropriate one to estimate the soil-structure interaction effects. (orig./HP)

  15. Computational strategies for the automated design of RNA nanoscale structures from building blocks using NanoTiler.

    Science.gov (United States)

    Bindewald, Eckart; Grunewald, Calvin; Boyle, Brett; O'Connor, Mary; Shapiro, Bruce A

    2008-10-01

    One approach to designing RNA nanoscale structures is to use known RNA structural motifs such as junctions, kissing loops or bulges and to construct a molecular model by connecting these building blocks with helical struts. We previously developed an algorithm for detecting internal loops, junctions and kissing loops in RNA structures. Here we present algorithms for automating or assisting many of the steps that are involved in creating RNA structures from building blocks: (1) assembling building blocks into nanostructures using either a combinatorial search or constraint satisfaction; (2) optimizing RNA 3D ring structures to improve ring closure; (3) sequence optimisation; (4) creating a unique non-degenerate RNA topology descriptor. This effectively creates a computational pipeline for generating molecular models of RNA nanostructures and more specifically RNA ring structures with optimized sequences from RNA building blocks. We show several examples of how the algorithms can be utilized to generate RNA tecto-shapes.

  16. Computational strategies for the automated design of RNA nanoscale structures from building blocks using NanoTiler☆

    Science.gov (United States)

    Bindewald, Eckart; Grunewald, Calvin; Boyle, Brett; O’Connor, Mary; Shapiro, Bruce A.

    2013-01-01

    One approach to designing RNA nanoscale structures is to use known RNA structural motifs such as junctions, kissing loops or bulges and to construct a molecular model by connecting these building blocks with helical struts. We previously developed an algorithm for detecting internal loops, junctions and kissing loops in RNA structures. Here we present algorithms for automating or assisting many of the steps that are involved in creating RNA structures from building blocks: (1) assembling building blocks into nanostructures using either a combinatorial search or constraint satisfaction; (2) optimizing RNA 3D ring structures to improve ring closure; (3) sequence optimisation; (4) creating a unique non-degenerate RNA topology descriptor. This effectively creates a computational pipeline for generating molecular models of RNA nanostructures and more specifically RNA ring structures with optimized sequences from RNA building blocks. We show several examples of how the algorithms can be utilized to generate RNA tecto-shapes. PMID:18838281

  17. Composite structures of steel and concrete beams, slabs, columns, and frames for buildings

    CERN Document Server

    Johnson, R P

    2008-01-01

    This book sets out the basic principles of composite construction with reference to beams, slabs, columns and frames, and their applications to building structures. It deals with the problems likely to arise in the design of composite members in buildings, and relates basic theory to the design approach of Eurocodes 2, 3 and 4.The new edition is based for the first time on the finalised Eurocode for steel/concrete composite structures.

  18. Comparison of the inelastic response of steel building frames to strong earthquake and underground nuclear explosion ground motion

    International Nuclear Information System (INIS)

    Murray, R.C.; Tokarz, F.J.

    1976-01-01

    Analytic studies were made of the adequacy of simulating earthquake effects at the Nevada Test Site for structural testing purposes. It is concluded that underground nuclear explosion ground motion will produce inelastic behavior and damage comparable to that produced by strong earthquakes. The generally longer duration of earthquakes compared with underground nuclear explosions does not appear to significantly affect the structural behavior of the building frames considered. A comparison of maximum ductility ratios, maximum story drifts, and maximum displacement indicate similar structural behavior for both types of ground motion. Low yield (10 - kt) underground nuclear explosions are capable of producing inelastic behavior in large structures. Ground motion produced by underground nuclear explosions can produce inelastic earthquake-like effects in large structures and could be used for testing large structures in the inelastic response regime. The Nevada Test Site is a feasible earthquake simulator for testing large structures

  19. Structural capacity assessment of machine-building enterprises and associations

    Directory of Open Access Journals (Sweden)

    Prilutskay Maria

    2017-01-01

    Full Text Available Multidirectional tendencies of machine-building enterprises integration and disintegration resulted in the emergence of the formal and informal associations. These associations consist of the obviously and/or implicitly affiliated legal entities. Thus, a new element appears in the direct enterprise environment, i.e a management company or a head enterprise. The management company influences the participants even in an informal association. New environment restrictions led to the changes in the management structure. The paper considers the enterprise structures interrelation: organizational, financial, production, resource, and others. The authors draw a conclusion that the structures are hierarchy, and there are the coherence structures assessment criteria. The coordinated structures form the structural capacity of the enterprise. The suggested assessment coherence criteria (for example resource and functional structures allow estimating the structural potential and defining the directions of the enterprise efficiency increase.

  20. Analysis of responses to the microgeneration strategy and low carbon buildings programme consultation

    Energy Technology Data Exchange (ETDEWEB)

    Gibbard, J; Long, S; McCartney, K; Rushton, K

    2005-10-15

    This report summarises and analyses the written responses to the consultation document, 'Microgeneration Strategy and Low Carbon Buildings Programme', issued by the Department of Trade and Industry (DTI) in June 2005. Responses were received from 204 different organisations representing 29 stakeholder groups. The consultation document contained 41 core questions divided into eight sections: general; product development and deployment; communications; economics; installation; Low Carbon Buildings Programme; physical infrastructure; and local authorities and regional bodies. In the analysis, the responses to these questions were categorised according to whether they represented a 'clear consensus', a 'majority view', 'supporting themes' and 'divergent themes'. Using these categories, stakeholder agreement on the eight strategic issues is summarised in a matrix. The report is divided into three sections: introduction; summary of responses; and key findings. The respondents are listed in an appendix. Another appendix reproduces the consultation questions.

  1. Dynamic behavior structural response and capacity evaluation of the standardized WWER-1000 nuclear power plants subjected to severe loading conditions

    International Nuclear Information System (INIS)

    Ambriashvili, Y.K.; Krutzik, N.J.

    1993-01-01

    In order to verify the structural capacity of standardized WWER-1000 MW nuclear power plants, comprehensive static and dynamic analyses were performed in cooperation between Siemens and Atomenergoprojekt. The main goal of these investigations was to perform of a number of seismic analyses of standardized WWER-1000 reactor buildings on the basis of 13 given seismological inputs, taking into account the local soil conditions at 17 different sites defined by in-situ investigations. The analyses were based on appropriate mathematical models (equivalent beam models as well as detailed spatial surface element models) of the coupled vibrating structures (base structure, outer structure, containment, inner structure) and of the layered soil. The analyses were mainly performed using the indirect method (substructure method). Based on the results of the seismic analysis as well as the results of static analysis (pressure and temperature due to LOCA, dead weight, prestressing) an assessment was made of the seismic safety of the containment and the reactor building. Using a complex 3-dimensional model of the structure and the soil, the influence of the flexibility of the basement structure on the structural response was also studied. The structural analyses of the WWER-1000 reactor building led to the conclusion that its design accounts well for the main factors governing the dynamic behavior of the building. The assessment of the forces acting in the structures shows that the bearing capacity of the analyzed building structure corresponds to an earthquake intensity of about 0.2 g to 0.25 g

  2. Practical guidelines to select and scale earthquake records for nonlinear response history analysis of structures

    Science.gov (United States)

    Kalkan, Erol; Chopra, Anil K.

    2010-01-01

    Earthquake engineering practice is increasingly using nonlinear response history analysis (RHA) to demonstrate performance of structures. This rigorous method of analysis requires selection and scaling of ground motions appropriate to design hazard levels. Presented herein is a modal-pushover-based scaling (MPS) method to scale ground motions for use in nonlinear RHA of buildings and bridges. In the MPS method, the ground motions are scaled to match (to a specified tolerance) a target value of the inelastic deformation of the first-'mode' inelastic single-degree-of-freedom (SDF) system whose properties are determined by first-'mode' pushover analysis. Appropriate for first-?mode? dominated structures, this approach is extended for structures with significant contributions of higher modes by considering elastic deformation of second-'mode' SDF system in selecting a subset of the scaled ground motions. Based on results presented for two bridges, covering single- and multi-span 'ordinary standard' bridge types, and six buildings, covering low-, mid-, and tall building types in California, the accuracy and efficiency of the MPS procedure are established and its superiority over the ASCE/SEI 7-05 scaling procedure is demonstrated.

  3. Comparison of SISEC code simulations with earthquake data of ordinary and base-isolated buildings

    International Nuclear Information System (INIS)

    Wang, C.Y.; Gvildys, J.

    1991-01-01

    At Argonne National Laboratory (ANL), a 3-D computer program SISEC (Seismic Isolation System Evaluation Code) is being developed for simulating the system response of isolated and ordinary structures (Wang et al. 1991). This paper describes comparison of SISEC code simulations with building response data of actual earthquakes. To ensure the accuracy of analytical simulations, recorded data of full-size reinforced concrete structures located in Sendai, Japan are used in this benchmark comparison. The test structures consist of two three-story buildings, one base-isolated and the other one ordinary founded. They were constructed side by side to investigate the effect of base isolation on the acceleration response. Among 20 earthquakes observed since April 1989, complete records of three representative earthquakes, no.2, no.6, and no.17, are used for the code validation presented in this paper. Correlations of observed and calculated accelerations at all instrument locations are made. Also, relative response characteristics of ordinary and isolated building structures are investigated. (J.P.N.)

  4. Staphylococcal Bap Proteins Build Amyloid Scaffold Biofilm Matrices in Response to Environmental Signals.

    Directory of Open Access Journals (Sweden)

    Agustina Taglialegna

    2016-06-01

    Full Text Available Biofilms are communities of bacteria that grow encased in an extracellular matrix that often contains proteins. The spatial organization and the molecular interactions between matrix scaffold proteins remain in most cases largely unknown. Here, we report that Bap protein of Staphylococcus aureus self-assembles into functional amyloid aggregates to build the biofilm matrix in response to environmental conditions. Specifically, Bap is processed and fragments containing at least the N-terminus of the protein become aggregation-prone and self-assemble into amyloid-like structures under acidic pHs and low concentrations of calcium. The molten globule-like state of Bap fragments is stabilized upon binding of the cation, hindering its self-assembly into amyloid fibers. These findings define a dual function for Bap, first as a sensor and then as a scaffold protein to promote biofilm development under specific environmental conditions. Since the pH-driven multicellular behavior mediated by Bap occurs in coagulase-negative staphylococci and many other bacteria exploit Bap-like proteins to build a biofilm matrix, the mechanism of amyloid-like aggregation described here may be widespread among pathogenic bacteria.

  5. Bio-inspired fabrication of stimuli-responsive photonic crystals with hierarchical structures and their applications

    International Nuclear Information System (INIS)

    Lu, Tao; Peng, Wenhong; Zhu, Shenmin; Zhang, Di

    2016-01-01

    When the constitutive materials of photonic crystals (PCs) are stimuli-responsive, the resultant PCs exhibit optical properties that can be tuned by the stimuli. This can be exploited for promising applications in colour displays, biological and chemical sensors, inks and paints, and many optically active components. However, the preparation of the required photonic structures is the first issue to be solved. In the past two decades, approaches such as microfabrication and self-assembly have been developed to incorporate stimuli-responsive materials into existing periodic structures for the fabrication of PCs, either as the initial building blocks or as the surrounding matrix. Generally, the materials that respond to thermal, pH, chemical, optical, electrical, or magnetic stimuli are either soft or aggregate, which is why the manufacture of three-dimensional hierarchical photonic structures with responsive properties is a great challenge. Recently, inspired by biological PCs in nature which exhibit both flexible and responsive properties, researchers have developed various methods to synthesize metals and metal oxides with hierarchical structures by using a biological PC as the template. This review will focus on the recent developments in this field. In particular, PCs with biological hierarchical structures that can be tuned by external stimuli have recently been successfully fabricated. These findings offer innovative insights into the design of responsive PCs and should be of great importance for future applications of these materials. (topical review)

  6. Structural integrity analysis of an Ignalina nuclear power plant building subjected to an airplane crash

    International Nuclear Information System (INIS)

    Dundulis, Gintautas; Kulak, Ronald F.; Marchertas, Algirdas; Uspuras, Eugenijus

    2007-01-01

    Recent terrorist attacks using commandeered commercial airliners on civil structures have raised the issue of the ability of nuclear power plants to survive the consequences of an airliner crash. The structural integrity analysis due to the effects of an aircraft crash on an Ignalina nuclear power plant (INPP) accident localization system (ALS) building is the subject of this paper. A combination of the finite element method and empirical relationships were used for the analysis. A global structural integrity analysis was performed for a portion of the ALS building using the dynamic loading from an aircraft crash impact model. The local effects caused by impact of the aircraft's engine on the building wall were evaluated independently by using an empirical formula. The results from the crash analysis of a twin engine commercial aircraft show that the impacted reinforced concrete wall of the ALS building will not have through-the-wall concrete failure, and the reinforcement will not fail. Strain-rate effects were found to delay the onset of cracking. Therefore, the structural integrity of the impacted wall of the INPP ALS building will be maintained during the crash event studied

  7. Structural integrity analysis of an Ignalina nuclear power plant building subjected to an airplane crash

    Energy Technology Data Exchange (ETDEWEB)

    Dundulis, Gintautas [Laboratory of Nuclear Installation Safety, Lithuanian Energy Institute, 3 Breslaujos, 44403 Kaunas-35 (Lithuania)]. E-mail: gintas@isag.lei.lt; Kulak, Ronald F. [RFK Engineering Mechanics Consultants (United States); Marchertas, Algirdas [Northern Illinois University (United States); Uspuras, Eugenijus [Laboratory of Nuclear Installation Safety, Lithuanian Energy Institute, 3 Breslaujos, 44403 Kaunas-35 (Lithuania)

    2007-08-15

    Recent terrorist attacks using commandeered commercial airliners on civil structures have raised the issue of the ability of nuclear power plants to survive the consequences of an airliner crash. The structural integrity analysis due to the effects of an aircraft crash on an Ignalina nuclear power plant (INPP) accident localization system (ALS) building is the subject of this paper. A combination of the finite element method and empirical relationships were used for the analysis. A global structural integrity analysis was performed for a portion of the ALS building using the dynamic loading from an aircraft crash impact model. The local effects caused by impact of the aircraft's engine on the building wall were evaluated independently by using an empirical formula. The results from the crash analysis of a twin engine commercial aircraft show that the impacted reinforced concrete wall of the ALS building will not have through-the-wall concrete failure, and the reinforcement will not fail. Strain-rate effects were found to delay the onset of cracking. Therefore, the structural integrity of the impacted wall of the INPP ALS building will be maintained during the crash event studied.

  8. Structural health and dynamic behavior of residential buildings: field challenges in the rehab of damaged reinforced concrete

    Directory of Open Access Journals (Sweden)

    Chalhoub M. S.

    2014-01-01

    Full Text Available Reinforced concrete buildings require special consideration under dynamic excitations due to their anisotropic material properties. Strain compatibility equations are used in concrete analysis and design with assumptions about the stress and strain field across member section and member length. However, these assumptions fall short of describing real life behavior when concrete elements deteriorate, age or undergo cyclic loading. This paper addresses the structural health of reinforced concrete buildings and proposes an analytical model to account for concrete damage through loss of bond. The proposed model relates steel loading that causes bond distress to design parameters such as development length and bar properties, and therefore could be complemented by field measurement. The paper proposes a diagnosis method and discusses the sustainability of the structure by assisting in a simplistic decision rule as to whether to perform minor fixes, major rehabilitation, or disposal. Emphasis is placed on the difference between reversible and irreversible effects of cyclic loading on structural behaviour, and draws a distinction between damage to the girder and damage to the column in the overall structural system. The model is compared to empirical results to address field challenges faced when the structure is subjected to severe conditions in its ambient environment, or to unusual loading. Deterioration in concrete causes alteration in its composite behavior with the reinforcing steel. This affects the fundamental period of the structure, and its response to seismic loading.

  9. Structural health monitoring on medium rise reinforced concrete building using ambient vibration method

    Science.gov (United States)

    Kamarudin, A. F.; Mokhatar, S. N.; Zainal Abidin, M. H.; Daud, M. E.; Rosli, M. S.; Ibrahim, A.; Ibrahim, Z.; Noh, M. S. Md

    2018-04-01

    Monitoring of structural health from initial stage of building construction to its serviceability is an ideal practise to assess for any structural defects or damages. Structural integrity could be intruded by natural destruction or structural deterioration, and worse if without remedy action on monitoring, building re-assessment or maintenance is taken. In this study the application of ambient vibration (AV) testing is utilized to evaluate the health of eighth stories medium rise reinforced concrete building in Universiti Tun Hussein Onn Malaysia (UTHM), based comparison made between the predominant frequency, fo, determined in year 2012 and 2017. For determination of fo, popular method of Fourier Amplitude Spectra (FAS) was used to transform the ambient vibration time series by using 1 Hz tri-axial seismometer sensors and City SharkII data recorder. From the results, it shows the first mode frequencies from FAS curves indicate at 2.04 Hz in 2012 and 1.97 Hz in 2017 with only 3.14% of frequency reduction. However, steady state frequencies shown at the second and third modes frequencies of 2.42 Hz and 3.31 Hz by both years. Two translation mode shapes were found at the first and second mode frequencies in the North-South (NS-parallel to building transverse axis) and East-West (EsW-parallel to building longitudinal axis) components, and the torsional mode shape shows as the third mode frequency in both years. No excessive deformation amplitude was found at any selective floors based on comparison made between three mode shapes produced, that could bring to potential feature of structural deterioration. Low percentages of natural frequency disparity within five years of duration interval shown by the first mode frequencies under ambient vibration technique was considered in good health state, according to previous researchers recommendation at acceptable percentages below 5 to 10% over the years.

  10. Structure Building Predicts Grades in College Psychology and Biology

    Science.gov (United States)

    Arnold, Kathleen M.; Daniel, David B.; Jensen, Jamie L.; McDaniel, Mark A.; Marsh, Elizabeth J.

    2016-01-01

    Knowing what skills underlie college success can allow students, teachers, and universities to identify and to help at-risk students. One skill that may underlie success across a variety of subject areas is structure building, the ability to create mental representations of narratives (Gernsbacher, Varner, & Faust, 1990). We tested if…

  11. Dynamic analysis of reactor containment building using axisymmetric finite element model

    International Nuclear Information System (INIS)

    Thakkar, S.K.; Dubey, R.N.

    1989-01-01

    The structural safety of nuclear reactor building during earthquake is of great importance in view of possibility of radiation hazards. The rational evaluation of forces and displacements in various portions of structure and foundation during strong ground motion is most important for safe performance and economic design of the reactor building. The accuracy of results of dynamic analysis is naturally dependent on the type of mathematical model employed. Three types of mathematical models are employed for dynamic analysis of reactor building beam model axisymmetric finite element model and three dimensional model. In this paper emphasis is laid on axisymmetric model. This model of containment building is considered a reinfinement over conventional beam model of the structure. The nuclear reactor building on a rocky foundation is considered herein. The foundation-structure interaction is relatively less in this condition. The objective of the paper is to highlight the significance of modelling of non-axisymmetric portion of building, such as reactor internals by equivalent axisymmetric body, on the structural response of the building

  12. Analysis of responses to the microgeneration strategy and low carbon buildings programme consultation

    Energy Technology Data Exchange (ETDEWEB)

    Gibbard, J.; Long, S.; McCartney, K.; Rushton, K.

    2005-10-15

    This report summarises and analyses the written responses to the consultation document, 'Microgeneration Strategy and Low Carbon Buildings Programme', issued by the Department of Trade and Industry (DTI) in June 2005. Responses were received from 204 different organisations representing 29 stakeholder groups. The consultation document contained 41 core questions divided into eight sections: general; product development and deployment; communications; economics; installation; Low Carbon Buildings Programme; physical infrastructure; and local authorities and regional bodies. In the analysis, the responses to these questions were categorised according to whether they represented a 'clear consensus', a 'majority view', 'supporting themes' and 'divergent themes'. Using these categories, stakeholder agreement on the eight strategic issues is summarised in a matrix. The report is divided into three sections: introduction; summary of responses; and key findings. The respondents are listed in an appendix. Another appendix reproduces the consultation questions.

  13. Reactor building seismic analysis of a PWR type - NPP

    International Nuclear Information System (INIS)

    Kakubo, Masao

    1983-01-01

    Earthquake engineering studies raised up in Brazil during design licensing and construction phases of Almirante Alvaro Alberto NPP, units 1 and 2. State of art of soil - structure interaction analysis with particular reference to the impedance function calculation analysis with particular reference to the impedance function calculation of a group of pile is presented in this M.Sc. Dissertation, as an example the reactor building dynamic response of a 1325 MWe NPP PWR type is calculated. The reactor building is supported by a pile foundation with 2002 end bearing piles. Upper and lower bound soil parameters are considered in order to observe their influence on dynamic response of structure. Dynamic response distribution on pile heads show pile-soil-pile interaction effects. (author)

  14. Dynamic analysis and response spectra for the main process building of a reprocessing plant

    International Nuclear Information System (INIS)

    Hilpert, H.J.; Henkel, F.O.

    1988-01-01

    This paper deals with the determination of the floor response spectra for the main process building of the planned reprocessing plant due to the special loading conditions of earthquake, airplane crash and blast. With these spectra the stress and strain of the components and their bearing forces which react on the building can be calculated. Some special problems depending on the length of the building are not yet answered and will be discussed later. (orig.)

  15. Measuring structural (un)safety in the Dutch building industry

    NARCIS (Netherlands)

    Terwel, K.C.; Waarts, P; E Rademaeker, de

    2010-01-01

    The last 10 years the Dutch Building Industry was shocked by several major accidents. In 2001 the steel structure of a theatre in Hoorn collapsed during erection. No one was hurt, because it collapsed during the night. In 2002 part of the parking deck of a hotel collapsed just some time after a

  16. DIRECT GEOREFERENCING OF UAV DATA BASED ON SIMPLE BUILDING STRUCTURES

    Directory of Open Access Journals (Sweden)

    W. Tampubolon

    2016-06-01

    Full Text Available Unmanned Aerial Vehicle (UAV data acquisition is more flexible compared with the more complex traditional airborne data acquisition. This advantage puts UAV platforms in a position as an alternative acquisition method in many applications including Large Scale Topographical Mapping (LSTM. LSTM, i.e. larger or equal than 1:10.000 map scale, is one of a number of prominent priority tasks to be solved in an accelerated way especially in third world developing countries such as Indonesia. As one component of fundamental geospatial data sets, large scale topographical maps are mandatory in order to enable detailed spatial planning. However, the accuracy of the products derived from the UAV data are normally not sufficient for LSTM as it needs robust georeferencing, which requires additional costly efforts such as the incorporation of sophisticated GPS Inertial Navigation System (INS or Inertial Measurement Unit (IMU on the platform and/or Ground Control Point (GCP data on the ground. To reduce the costs and the weight on the UAV alternative solutions have to be found. This paper outlines a direct georeferencing method of UAV data by providing image orientation parameters derived from simple building structures and presents results of an investigation on the achievable results in a LSTM application. In this case, the image orientation determination has been performed through sequential images without any input from INS/IMU equipment. The simple building structures play a significant role in such a way that geometrical characteristics have been considered. Some instances are the orthogonality of the building’s wall/rooftop and the local knowledge of the building orientation in the field. In addition, we want to include the Structure from Motion (SfM approach in order to reduce the number of required GCPs especially for the absolute orientation purpose. The SfM technique applied to the UAV data and simple building structures additionally presents an

  17. Accurate facade feature extraction method for buildings from three-dimensional point cloud data considering structural information

    Science.gov (United States)

    Wang, Yongzhi; Ma, Yuqing; Zhu, A.-xing; Zhao, Hui; Liao, Lixia

    2018-05-01

    Facade features represent segmentations of building surfaces and can serve as a building framework. Extracting facade features from three-dimensional (3D) point cloud data (3D PCD) is an efficient method for 3D building modeling. By combining the advantages of 3D PCD and two-dimensional optical images, this study describes the creation of a highly accurate building facade feature extraction method from 3D PCD with a focus on structural information. The new extraction method involves three major steps: image feature extraction, exploration of the mapping method between the image features and 3D PCD, and optimization of the initial 3D PCD facade features considering structural information. Results show that the new method can extract the 3D PCD facade features of buildings more accurately and continuously. The new method is validated using a case study. In addition, the effectiveness of the new method is demonstrated by comparing it with the range image-extraction method and the optical image-extraction method in the absence of structural information. The 3D PCD facade features extracted by the new method can be applied in many fields, such as 3D building modeling and building information modeling.

  18. Aggregation Potentials for Buildings - Business Models of Demand Response and Virtual Power Plants

    DEFF Research Database (Denmark)

    Ma, Zheng; Billanes, Joy Dalmacio; Jørgensen, Bo Nørregaard

    2017-01-01

    programs, national regulations and energy market structures strongly influence buildings’ participation in the aggregation market. Under the current Nordic market regulation, business model one is the most feasible one, and business model two faces more challenges due to regulation barriers and limited...... aggregation market with unclear incentives is still a challenge for buildings to participate in the aggregation market. However, few studies have investigated business models for building participation in the aggregation market. Therefore, this paper develops four business models for buildings to participate...

  19. Building concepts against airplane crash

    International Nuclear Information System (INIS)

    Henkel, F.O.; Woelfel, H.

    1984-01-01

    In Germany safety related buildings of nuclear facilities as well as their equipment are to be designed against airplane crash. While the safety of the structure itself can always be guaranteed by structural means, the induced vibrations may cause severe problems for the equipment. Considerable effort was expended in recent years to comprehend the load case airplane crash in a more exact manner and to evaluate reasonable floor response spectra. Besides this analytical effort, investigations are cited to minimize the induced vibrations by new structural concepts. The present paper gives a survey concerning the development of structural concepts, culminating in the double shell structures that are state of the art today. Then the idea of spring supports, as it is known for the aseismic foundation of buildings, is further developed to a new spring concept which reduces the induced vibrations in an optimum way in the load case airplane crash and which additionally isolates earthquake vibrations. (orig.)

  20. Study of responses of 64-story Rincon Building to Napa, Fremont, Piedmont, San Ramon earthquakes and ambient motions

    Science.gov (United States)

    Çelebi, Mehmet; Hooper, John; Klemencic, Ron

    2017-01-01

    We analyze the recorded responses of a 64-story, instrumented, concrete core shear wall building in San Francisco, California, equipped with tuned sloshing liquid dampers (TSDs) and buckling restraining braces (BRBs). Previously, only ambient data from the 72-channel array in the building were studied (Çelebi et al. 2013). Recently, the 24 August 2014 Mw 6.0 Napa and three other earthquakes were recorded. The peak accelerations of ambient and the larger Napa earthquake responses at the basement are 0.12 cm/s/s and 5.2 cm/s/s respectively—a factor of ~42. At the 61st level, they are 0.30 cm/s/s (ambient) and 16.8 cm/s/s (Napa), respectively—a factor of ~56. Fundamental frequencies (NS ~ 0.3, EW ~ 0.27 Hz) from earthquake responses vary within an insignificant frequency band of ~0.02–0.03 Hz when compared to those from ambient data. In the absence of soil-structure interaction (SSI), these small and insignificant differences may be attributed to (1) identification errors, (2) any nonlinear behavior, and (3) shaking levels that are not large enough to activate the BRBs and TSDs to make significant shifts in frequencies and increase damping.

  1. The importance of building construction materials relative to other factors affecting structure survival during wildfire

    Science.gov (United States)

    Syphard, Alexandra D.; Brennan, Teresa J.; Keeley, Jon E.

    2017-01-01

    Structure loss to wildfire is a serious problem in wildland-urban interface areas across the world. Laboratory experiments suggest that fire-resistant building construction and design could be important for reducing structure destruction, but these need to be evaluated under real wildfire conditions, especially relative to other factors. Using empirical data from destroyed and surviving structures from large wildfires in southern California, we evaluated the relative importance of building construction and structure age compared to other local and landscape-scale variables associated with structure survival. The local-scale analysis showed that window preparation was especially important but, in general, creating defensible space adjacent to the home was as important as building construction. At the landscape scale, structure density and structure age were the two most important factors affecting structure survival, but there was a significant interaction between them. That is, young structure age was most important in higher-density areas where structure survival overall was more likely. On the other hand, newer-construction structures were less likely to survive wildfires at lower density. Here, appropriate defensible space near the structure and accessibility to major roads were important factors. In conclusion, community safety is a multivariate problem that will require a comprehensive solution involving land use planning, fire-safe construction, and property maintenance.

  2. Making the Case for Green Building: Cataloging the Benefits of Environmentally Responsible Design & Construction

    Science.gov (United States)

    Wilson, Alex

    2008-01-01

    To those entrenched in the green building world, the benefits seem obvious. Why would anyone choose to build in a way that isn't comfortable, healthy, energy efficient, and environmentally responsible? Even within a single college or university project, different team members often have different reasons for promoting a green agenda. Architects…

  3. Dynamic analysis of auxiliary buildings in nuclear power plants

    International Nuclear Information System (INIS)

    Subramanian, K.V.; Madhava Rao, A.S.; Warudkar, A.S.

    1989-01-01

    All nuclear power plants have a large number of auxiliary buildings housing various services and control systems required for the operation of the plant. Illustrative examples are turbine building, control building, service building etc. These buildings are seismically qualified as Class I or Class II structures. Usually, these auxiliary buildings are of low rise type with two or three floors and floor heights varying from five to eight meters and of framed construction in steel or concrete or a combination of both the materials. The floors are usually staggered with large cutouts and may not extend over the full area in plan. Some of the bays are often of double story height with the columns continuous over a story in order to accommodate cranes and other equipment. The structural elements supporting the roof may consist of steel roof trusses instead of beams. The seismic analysis of these structures involves the formulation of the analytical model that can simulate the physical behavior of the structure as close as possible taking into consideration the practical aspects. The criteria adopted to formulate the mathematical model has an important bearing on the evaluated dynamic characteristics and seismic response

  4. Phase space interrogation of the empirical response modes for seismically excited structures

    Science.gov (United States)

    Paul, Bibhas; George, Riya C.; Mishra, Sudib K.

    2017-07-01

    Conventional Phase Space Interrogation (PSI) for structural damage assessment relies on exciting the structure with low dimensional chaotic waveform, thereby, significantly limiting their applicability to large structures. The PSI technique is presently extended for structure subjected to seismic excitations. The high dimensionality of the phase space for seismic response(s) are overcome by the Empirical Mode Decomposition (EMD), decomposing the responses to a number of intrinsic low dimensional oscillatory modes, referred as Intrinsic Mode Functions (IMFs). Along with their low dimensionality, a few IMFs, retain sufficient information of the system dynamics to reflect the damage induced changes. The mutually conflicting nature of low-dimensionality and the sufficiency of dynamic information are taken care by the optimal choice of the IMF(s), which is shown to be the third/fourth IMFs. The optimal IMF(s) are employed for the reconstruction of the Phase space attractor following Taken's embedding theorem. The widely referred Changes in Phase Space Topology (CPST) feature is then employed on these Phase portrait(s) to derive the damage sensitive feature, referred as the CPST of the IMFs (CPST-IMF). The legitimacy of the CPST-IMF is established as a damage sensitive feature by assessing its variation with a number of damage scenarios benchmarked in the IASC-ASCE building. The damage localization capability, remarkable tolerance to noise contamination and the robustness under different seismic excitations of the feature are demonstrated.

  5. Balanced Evaluation of Structural and Environmental Performances in Building Design

    Directory of Open Access Journals (Sweden)

    Marco Lamperti Tornaghi

    2018-03-01

    Full Text Available The design of new buildings, and even more the rehabilitation of existing ones, needs to satisfy modern criteria in terms of energy efficiency and environmental performance, within the context of adequate safety requirements. Tackling all these needs at the same time is cumbersome, as demonstrated by several experiences during recent earthquakes, where the improvement of energy performance vanished by seismic-induced damages. The costs of energy retrofitting must be added to the normal losses caused by the earthquake. Even though the minimum safety requirements are met (no collapse, the damage due to earthquake might be enough to waste the investment made to improve energy efficiency. Since these measures are often facilitated by corresponding incentives, the use of public funding is not cost effective. The application of the existing impact assessment methods is typically performed at the end of the architectural and structural design process. Thus, no real optimisation can be achieved, because a good structural solution could correspond to a poor environmental performance and vice versa. The proposed Sustainable Structural Design method (SSD considers both environmental and structural parameters in the life cycle perspective. The integration of environmental data in the structural performance is the focus of the method. Structural performances are considered in a probabilistic approach, through the introduction of a simplified Performance Based Assessment method. Finally, the SSD method is implemented with a case-study of an office-occupancy building, both for precast and cast-in-situ structural systems, with the aim to find the best solution in terms of sustainability and structural performance for the case at hand.

  6. Web-based energy information systems for energy management and demand response in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Motegi, Naoya; Piette, Mary Ann; Kinney, Satkartar; Herter, Karen

    2003-04-18

    Energy Information Systems (EIS) for buildings are becoming widespread in the U.S., with more companies offering EIS products every year. As a result, customers are often overwhelmed by the quickly expanding portfolio of EIS feature and application options, which have not been clearly identified for consumers. The object of this report is to provide a technical overview of currently available EIS products. In particular, this report focuses on web-based EIS products for large commercial buildings, which allow data access and control capabilities over the Internet. EIS products combine software, data acquisition hardware, and communication systems to collect, analyze and display building information to aid commercial building energy managers, facility managers, financial managers and electric utilities in reducing energy use and costs in buildings. Data types commonly processed by EIS include energy consumption data; building characteristics; building system data, such as heating, ventilation, and air-conditioning (HVAC) and lighting data; weather data; energy price signals; and energy demand-response event information. This project involved an extensive review of research and trade literature to understand the motivation for EIS technology development. This study also gathered information on currently commercialized EIS. This review is not an exhaustive analysis of all EIS products; rather, it is a technical framework and review of current products on the market. This report summarizes key features available in today's EIS, along with a categorization framework to understand the relationship between EIS, Energy Management and Control Systems (EMCSs), and similar technologies. Four EIS types are described: Basic Energy Information Systems (Basic-EIS); Demand Response Systems (DRS); Enterprise Energy Management (EEM); and Web-based Energy Management and Control Systems (Web-EMCS). Within the context of these four categories, the following characteristics of EIS

  7. Building political will for HIV response: an operational model and strategy options.

    Science.gov (United States)

    Brinkerhoff, Derick W

    2016-10-01

    As global programs for HIV response look to transfer responsibility and financing increasingly to country governments, the political will to take on these responsibilities becomes increasingly prominent. However, defining and assessing political will are problematic; it involves intent and motivation, and thus is inherently difficult to observe. It is intimately connected to capacity and is contextually embedded. This article describes an operational model of political will comprised of seven components that are observable and measurable. Two case studies illustrate the application of the model and shed light on the interconnections among commitment, capacity and context: South Africa and China. Strategy options to build political will for HIV response identify possible actions for both government and civil society. Political will as a concept is most usefully viewed as integrated within larger political and bureaucratic processes, as a product of the complex array of incentives and disincentives that those processes create. However, this conclusion is not a recipe for discouragement or inaction. Agent-based conceptualizations of policy change offer a solid grounding for building political will that supports HIV policy and programs. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Building integrated PV for commercial and institutional structures, a sourcebook for architects

    Energy Technology Data Exchange (ETDEWEB)

    Eiffert, P.; Kiss, G.

    2000-02-14

    This sourcebook on building-integrated photovoltaics (BIPV) is intended for architects and designers interested in learning more about today's sustainable solar buildings. The booklet includes 16 design briefs describing actual structures; they illustrate how electricity-generating BIPV products (such as special roofing systems, vertical-wall systems, skylights, and awnings, all of which contain PV cells, modules, and films) can be integrated successfully into many different kinds of buildings. It also contains basic information about BIPV technologies, an overview of US product development activities and development programs, descriptions of major software design tools, and a bibliography.

  9. Reactor building with internal structure of which the movements are independent of those of the general raft and process for building these internal structures

    International Nuclear Information System (INIS)

    Hista, J.C.

    1982-01-01

    This reactor building includes a containment enclosure for the internal structures composed of a slab wedged on its periphery against the containment enclosure gusset and resting on the general raft by means of a peripheral bearing ring, a compressible layer being provided between the general raft and the slab [fr

  10. Computed versus measured response of HDR reactor building in large scale shaking tests

    International Nuclear Information System (INIS)

    Werkle, H.; Waas, G.

    1987-01-01

    The earthquake resistant design of NPP structures and their installations is commonly based on linear analysis methods. Nonlinear effects, which may occur during strong earthquakes, are approximately accounted for in the analysis by adjusting the structural damping values. Experimental investigations of nonlinear effects were performed with an extremely heavy shaker at the decommissioned HDR reactor building in West Germany. The tests were directed by KfK (Nuclear Research Center Karlsruhe, West Germany) and supported by several companies and institutes from West Germany, Switzerland and the USA. The objective was the dynamic repsonse behaviour of the structure, piping and components to strong earthquake-like shaking including nonlinear effects. This paper presents some results of safety analyses and measurements, which were performed prior and during the test series. It was intended to shake the building up to a level where only a marginal safety against global structural failure was left

  11. Seismic upgrading of the spent fuel storage building at Kozloduy NPP

    International Nuclear Information System (INIS)

    Alexandrov, A.; Borov, V.; Jordanov, M.; Karamanski, T.; Mihaylov, K.

    2001-01-01

    The Spent Fuel Storage Building at Kozloduy NPP site has been analysed for new review level earthquake with 0.2 g peak ground acceleration (compared to the initial design basis earthquake with 0.1 g PGA). The preliminary seismic analysis of the existing building structure using the 5% site specific response spectrum showed the need of seismic structural upgrading. Two upgrading concepts were evaluated on the basis of several factors. The main factor considered was preventing the collapse of the hall structure and the travelling cranes on the fuel storage area during and after a SSE. A three dimensional finite element model was created for the investigation of the seismic response of the existing structure and for the design of the building upgrading. The modelling of the heavy travelling crane and its sub-crane structure was one of the key points. Different configurations of the new upgrading and strengthening structures were investigated. Some interesting conclusions have been drawn from the experience in analysing and upgrading of such a complex industrial structure, comprised of elements with substantial differences in material, rigidity, construction and general behaviour. (author)

  12. Developing Dynamic Digital Image Correlation Technique to Monitor Structural Damage of Old Buildings under External Excitation

    Directory of Open Access Journals (Sweden)

    Ming-Hsiang Shih

    2014-01-01

    Full Text Available The capacity of buildings to resist external excitation is an important factor to consider for the structural design of buildings. When subject to external excitation, a building may suffer a certain degree of damages, and its residual capacity to resist external excitation cannot be evaluated. In this research, dynamic digital image correlation method combined with parameter evaluation available in system identification is used to evaluate the structural capacity to resist external excitation. The results reveal possible building latent safety problems so that timely structural reinforcement or dismantling of the building can be initiated to alleviate further damages. The results of experiments using the proposed method conform to the results obtained using the conventional method, but this method is more convenient and rapid than the latter in the subsequent procedure of data processing. If only the frequency change is used, the damages suffered by the building can be detected, but the damage location is not revealed. The interstory drift mode shape (IDMS based on the characteristic of story drift has higher sensitivity than the approximate story damage index (ADSI method based on modal frequency and vibration type; however, both indices can be used to determine the degree and location of building damages.

  13. Seismic response of structures by the response spectrum method

    International Nuclear Information System (INIS)

    Hadjian, A.H.

    1981-01-01

    The problems of the acceleration profile at the lower elevations of cantilever structures and the response of relatively rigid structures are explored. It is shown that the use of the conventional methods for the above problems provide very approximate results. An alternate combination of the modal responses is proposed that not only resolves the above problems but also provides better estimates of response for the complete range of structure frequencies. The procedure treats the relative and rigid body responses separately and then appropriately combines the two results. For the rigid range of frequencies (fundamental frequencies greater than about 2 Hz), the proposed procedure does not encounter any numerical difficulties because of the additive nature of the component responses; however, the application of the proposed procedure for very flexible structures causes accuracy problems since the rigid body effects tend to be subtractive from the flexural response of about equal magnitude. For this latter class of problems, the conventional approach of modal combination provides adequate results and avoids the above mentioned numerical difficulties. (orig.)

  14. Assessment of the seismic resistance of a ventilation stack on a reactor building

    International Nuclear Information System (INIS)

    Makovicka, Daniel; Makovicka, Daniel

    2005-01-01

    The paper analyzes the seismic resistance of a ventilation stack on a reactor building, including the possible reserves of increasing the resistance. Structures of this type are highly sensitive to seismic loads, as the tuning of the stack (the spectrum of its lowest natural frequencies) corresponds with the frequency spectrum of excitation due to seismic effects. The purpose of the paper is to present an example of an actual structure to show the character of the response of the structure, and the participation of the individual frequency components of the response in the overall stress and strain state of a structure of this type. The methodology for a numerical analysis of the structure is also given. The load of the stack proper is modified by the transfer characteristics of the building. In engineering practice, the system is usually divided into two subsystems: the building with the sub-base, and the stack proper. The level of justification for the application of this simplification depends on the distance of the natural frequencies of the stack from the natural frequencies of the building. Finally, the paper deals with possible errors in determining the actual seismic resistance of the stack structure

  15. Dynamic analysis and response spectra for the main processing building of a reprocessing plant

    International Nuclear Information System (INIS)

    Mischke, J.; Hilpert, H.J.; Henkel, F.O.

    1984-01-01

    The article deals with the determination of the floor response spectra for the main processing building of the planned reprocessing plant due to the special loading conditions of earthquake, airplane crash and blast. With these spectra the stress and strain of the components and their bearing forces which react on the building can be calculated. (orig.) [de

  16. Soil structure interaction model and variability of parameters in seismic analysis of nuclear island connected building

    International Nuclear Information System (INIS)

    Subramanian, K.V.; Palekar, S.M.; Bavare, M.S.; Mapari, H.A.; Patel, S.C.; Pillai, C.S.

    2005-01-01

    This paper provides salient features of the Soil Structure Interaction analysis of Nuclear Island Connected Building (NICB). The dynamic analysis of NICB is performed on a full 3D model accounting for the probable variation in the stiffness of the founding medium. A range analyses was performed to establish the effect of variability of subgrade parameters on the results of seismic analyses of NICB. This paper presents details of various analyses with respect to the subgrade model, uncertainties in subgrade properties, results of seismic analyses and a study of effect of the variability of parameters on the results of these analyses. The results of this study indicate that the variability of soil parameters beyond a certain value of shear wave velocity does not influence the response and in fact the response marginally diminishes. (authors)

  17. Biomimetic Architecture in Building Envelope Maintenance (A Literature

    Directory of Open Access Journals (Sweden)

    Agus Salim N.A.

    2014-01-01

    Full Text Available The study of biomimetic architecture on building envelope is the main structure of this research. The concept is believed more sustainable and efficient for energy saving, operating cost consumption, waste recycle and design renewal in the future. The inspiration from the nature developed the intention on this study to explore on what and how this concept to overcome the problems through design. Biomimicry does catch the attention of human to study more on the system and function of its nature course. The designers are not exception influenced by this concept when the form, shape, texture and colour inspired them in their design. The domination of building form will affect the building envelope as the skin of the structure. A clear impact on building failure is begun with building envelope appearance without a proper maintenance. The faults in building design place a heavy burden on the building for the rest of its operational life and there is no compensation for it. In such situations, the responsibility falls on the shoulders of the designer.

  18. Automatic Generation of Structural Building Descriptions from 3D Point Cloud Scans

    DEFF Research Database (Denmark)

    Ochmann, Sebastian; Vock, Richard; Wessel, Raoul

    2013-01-01

    We present a new method for automatic semantic structuring of 3D point clouds representing buildings. In contrast to existing approaches which either target the outside appearance like the facade structure or rather low-level geometric structures, we focus on the building’s interior using indoor...... scans to derive high-level architectural entities like rooms and doors. Starting with a registered 3D point cloud, we probabilistically model the affiliation of each measured point to a certain room in the building. We solve the resulting clustering problem using an iterative algorithm that relies...... on the estimated visibilities between any two locations within the point cloud. With the segmentation into rooms at hand, we subsequently determine the locations and extents of doors between adjacent rooms. In our experiments, we demonstrate the feasibility of our method by applying it to synthetic as well...

  19. Responses of a tall building with U.S. code-type instrumentation in Tokyo, Japan, to events before, during and after the Tohoku earthquake of 11 March 2011

    Science.gov (United States)

    Çelebi, Mehmet; Kashima, Toshihide; Ghahari, S. Farid; Abazarsa, Fariba; Taciroglu, Ertugrul

    2016-01-01

    The 11 March 2011 M 9.0 Tohoku earthquake generated long-duration shaking that propagated hundreds of kilometers from the epicenter and affected tall buildings in urban areas several hundred kilometers from the epicenter of the main shock. Recorded responses show that tall buildings were affected by long-period motions. This study presents the behavior and performance of a 37-story building in the Tsukuda area of Tokyo, Japan, as inferred from modal analyses of records retrieved for a time interval covering a few days before, during, and for several months after the main shock. The U.S. “code-type” array comprises three triaxial accelerometers deployed at three levels in the superstructure. Such a sparse array in a tall structure limits a reliable assessment, because its performance must be based on only the average drift ratios. Based on the inferred values of this parameter, the subject building was not structurally damaged.

  20. Deer herbivory reduces web-building spider abundance by simplifying forest vegetation structure

    Directory of Open Access Journals (Sweden)

    Elizabeth J. Roberson

    2016-09-01

    Full Text Available Indirect ecological effects are a common feature of ecological systems, arising when one species affects interactions among two or more other species. We examined how browsing by white-tailed deer (Odocoileus virginianus indirectly affected the abundance and composition of a web-building spider guild through their effects on the structure of the ground and shrub layers of northern hardwood forests. We examined paired plots consisting of deer-free and control plots in the Allegheny Plateau region Pennsylvania and Northern Highlands region of Wisconsin. We recorded the abundance of seven types of webs, each corresponding to a family of web-building spiders. We quantified vegetation structure and habitat suitability for the spiders by computing a web scaffold availability index (WSAI at 0.5 m and 1.0 m above the ground. At Northern Highlands sites, we recorded prey availability. Spider webs were twice as abundant in deer-free plots compared to control plots, while WSAI was 7–12 times greater in deerfree plots. Prey availability was lower in deer-free plots. With the exception of funnel web-builders, all spider web types were significantly more abundant in deer-free plots. Both deer exclusion and the geographic region of plots were significant predictors of spider community structure. In closed canopy forests with high browsing pressure, the low density of tree saplings and shrubs provides few locations for web-building spiders to anchor webs. Recruitment of these spiders may become coupled with forest disturbance events that increase tree and shrub recruitment. By modifying habitat structure, deer appear to indirectly modify arthropod food web interactions. As deer populations have increased in eastern North America over the past several decades, the effects of deer on web-building spiders may be widespread.

  1. Distributed Dynamic Condition Response Structures

    DEFF Research Database (Denmark)

    Hildebrandt, Thomas; Mukkamala, Raghava Rao

    We present distributed dynamic condition response structures as a declarative process model inspired by the workflow language employed by our industrial partner and conservatively generalizing labelled event structures. The model adds to event structures the possibility to 1) finitely specify...... as a labelled transition system. Exploration of the relationship between dynamic condition response structures and traditional models for concurrency, application to more complex scenarios, and further extensions of the model is left to future work....

  2. Principles of structural physics in building construction in the Egyptian desert

    Energy Technology Data Exchange (ETDEWEB)

    Awady El Wakil, Shafak El

    1981-12-01

    Building construction in accordance with the climate in oases of the Egyptian desert is discussed. Climatic conditions and the resulting consequences for structural physics play a major role. With the aid of Olgay's comfort diagram, requirements to be made on buildings in various oases are derived from the climatic data of these oases. To optimize the indoor climate, shading, heat storage and ventilation measures are discussed, and suggestions are made on how to make use of this knowledge in consideration of traditional Egyptian architecture.

  3. Utilization of structural steel in buildings.

    Science.gov (United States)

    Moynihan, Muiris C; Allwood, Julian M

    2014-08-08

    Over one-quarter of steel produced annually is used in the construction of buildings. Making this steel causes carbon dioxide emissions, which climate change experts recommend be reduced by half in the next 37 years. One option to achieve this is to design and build more efficiently, still delivering the same service from buildings but using less steel to do so. To estimate how much steel could be saved from this option, 23 steel-framed building designs are studied, sourced from leading UK engineering firms. The utilization of each beam is found and buildings are analysed to find patterns. The results for over 10 000 beams show that average utilization is below 50% of their capacity. The primary reason for this low value is 'rationalization'-providing extra material to reduce labour costs. By designing for minimum material rather than minimum cost, steel use in buildings could be drastically reduced, leading to an equivalent reduction in 'embodied' carbon emissions.

  4. Structural-Vibration-Response Data Analysis

    Science.gov (United States)

    Smith, W. R.; Hechenlaible, R. N.; Perez, R. C.

    1983-01-01

    Computer program developed as structural-vibration-response data analysis tool for use in dynamic testing of Space Shuttle. Program provides fast and efficient time-domain least-squares curve-fitting procedure for reducing transient response data to obtain structural model frequencies and dampings from free-decay records. Procedure simultaneously identifies frequencies, damping values, and participation factors for noisy multiple-response records.

  5. Active Disaster Response System for a Smart Building

    Science.gov (United States)

    Lin, Chun-Yen; Chu, Edward T.-H; Ku, Lun-Wei; Liu, Jane W. S.

    2014-01-01

    Disaster warning and surveillance systems have been widely applied to help the public be aware of an emergency. However, existing warning systems are unable to cooperate with household appliances or embedded controllers; that is, they cannot provide enough time for preparedness and evacuation, especially for disasters like earthquakes. In addition, the existing warning and surveillance systems are not responsible for collecting sufficient information inside a building for relief workers to conduct a proper rescue action after a disaster happens. In this paper, we describe the design and implementation of a proof of concept prototype, named the active disaster response system (ADRS), which automatically performs emergency tasks when an earthquake happens. ADRS can interpret Common Alerting Protocol (CAP) messages, published by an official agency, and actuate embedded controllers to perform emergency tasks to respond to the alerts. Examples of emergency tasks include opening doors and windows and cutting off power lines and gas valves. In addition, ADRS can maintain a temporary network by utilizing the embedded controllers; hence, victims trapped inside a building are still able to post emergency messages if the original network is disconnected. We conducted a field trial to evaluate the effectiveness of ADRS after an earthquake happened. Our results show that compared to manually operating emergency tasks, ADRS can reduce the operation time by up to 15 s, which is long enough for people to get under sturdy furniture, or to evacuate from the third floor to the first floor, or to run more than 100 m. PMID:25237897

  6. Development of building envelope structures; Udvikling af klimaskaermskonstruktioner

    Energy Technology Data Exchange (ETDEWEB)

    Monefeldt Tommerup, H. [Danmarks Tekniske Univ., Lyngby (Denmark); Munch-Andersen, J. [Statens Byggeforskningsinstitut, Hoersholm (Denmark); Kjaer Esbensen, P. [Danmarks Tekniske Univ., Lyngby (Denmark)

    2000-08-01

    The present report concludes the work concerning the development of building envelope constructions, which can form the basis of new buildings with considerably less heat demand than in the present building regulations. It has been made probable that it is technically possible to build exterior walls with less heat loss than those just complying with the requirements of the current building regulations with no considerable added use of material apart from insulation. In their structure many of the shown constructions resemble types that are used today, while others presuppose that one part of the wall is attached to the other part or possibly to the rafters. Calculations concerning the importance of heat capacity for a 100 m{sup 2} single-family house have been made which confirm that by using heavy rather than light envelope constructions the reduction of the heating requirements is relatively small. Therefore optimisation of the insulation level can be carried out separately on the building components. A method has been developed for the evaluation of the optimum insulation level for the individual building components of the building envelope based on life cycle cost analysis. The method is based on making up the changes in the operational energy costs/ heating-costs and the cost of construction due to a change in the insulation thickness over a 30-year period. The life span of the primary parts of the building envelope is estimated at 100 years. It is assumed that the gross energy consumption that covers the heating requirements and the heat loss (determined by a simple calculation of degree days) changes concurrently with the change in the insulation thickness, which has been proved to be a reasonable approximation. The life cycle cost analysis has been carried out for a test-house of about 100 m{sup 2} and with two different energy price scenarios: 0.60 dkk/kWh (including taxes and VAT) which roughly corresponds to the present energy price level, and 1.20 dkk

  7. Vibration Transmission in a Multi-Storey Lightweight Building

    DEFF Research Database (Denmark)

    Niu, Bin; Andersen, Lars Vabbersgaard; Kiel, Nikolaj

    2012-01-01

    This paper develops a parametric modelling and analysis approach to investigate the vibration transmission in lightweight buildings. The main focus of the research is to investigate the influence of geometry and configuration of the building on the vibration transmission. A building with a single...... including floor panels, external and internal wall panels, which are considered as beam-stiffened double-leaf panels. As a view to reduce the modelling and analysis cost, the panels are homogenized into equivalent composite shells with two isotropic skin layers and one orthotropic core layer. The material...... configurations of the building. Some observations can be drawn from the numerical examples: •Several frequency gaps are observed from the frequency response curve. A quite low response is obtained in these gaps due to the absence of structural Eigen modes. •The flanking transmission may play a significant role...

  8. Students' Environmental Responsibility and Their Willingness to Pay for Green Buildings

    Science.gov (United States)

    Attaran, Sharmin; Celik, Bilge Gokhan

    2015-01-01

    Purpose: The purpose of this study is to explore environmental attitudes and how such attitudes, when combined with a specific cost, can affect environmental behavior. Environmental attitudes are important to study due to the rising belief by building occupants that they are owed safe, healthy, environmentally responsible, and comfortable living…

  9. D Visualization of a Timber Frame Historic Building: Partite Usage and its Impact on the Structural System

    Science.gov (United States)

    Günay, S.

    2017-08-01

    Throughout their lifetime, historic buildings might be altered for different kind of usage for different purposes. If this new function or new usage requires utilization of the building in separate units, this separation might affect the historic building's functionality and structure and as a result its overall condition. Yorguc Pasa Mansion conservation project was prepared as a part of the Middle East Technical University (METU) Master's Program in Documentation and Conservation of Historic Monuments and Sites for the historic Yorguc Pasa Mansion. The mansion is a 19th century Ottoman Period timber frame building in Amasya, a Black Sea Region city in Turkey that has traces from different civilizations such as Hittites, Greeks, Romans and Ottomans. This paper aims to discuss the affects of the partite usage on structural conditions of timber frame buildings with the case study of Amasya Yorguc Pasa Mansion through the 3D visualized structural systems.

  10. Origami-inspired building block and parametric design for mechanical metamaterials

    Science.gov (United States)

    Jiang, Wei; Ma, Hua; Feng, Mingde; Yan, Leilei; Wang, Jiafu; Wang, Jun; Qu, Shaobo

    2016-08-01

    An origami-based building block of mechanical metamaterials is proposed and explained by introducing a mechanism model based on its geometry. According to our model, this origami mechanism supports response to uniaxial tension that depends on structure parameters. Hence, its mechanical properties can be tunable by adjusting the structure parameters. Experiments for poly lactic acid (PLA) samples were carried out, and the results are in good agreement with those of finite element analysis (FEA). This work may be useful for designing building blocks of mechanical metamaterials or other complex mechanical structures.

  11. Origami-inspired building block and parametric design for mechanical metamaterials

    International Nuclear Information System (INIS)

    Jiang, Wei; Ma, Hua; Feng, Mingde; Yan, Leilei; Wang, Jiafu; Wang, Jun; Qu, Shaobo

    2016-01-01

    An origami-based building block of mechanical metamaterials is proposed and explained by introducing a mechanism model based on its geometry. According to our model, this origami mechanism supports response to uniaxial tension that depends on structure parameters. Hence, its mechanical properties can be tunable by adjusting the structure parameters. Experiments for poly lactic acid (PLA) samples were carried out, and the results are in good agreement with those of finite element analysis (FEA). This work may be useful for designing building blocks of mechanical metamaterials or other complex mechanical structures. (paper)

  12. The use of methods of structural optimization at the stage of designing high-rise buildings with steel construction

    Science.gov (United States)

    Vasilkin, Andrey

    2018-03-01

    The more designing solutions at the search stage for design for high-rise buildings can be synthesized by the engineer, the more likely that the final adopted version will be the most efficient and economical. However, in modern market conditions, taking into account the complexity and responsibility of high-rise buildings the designer does not have the necessary time to develop, analyze and compare any significant number of options. To solve this problem, it is expedient to use the high potential of computer-aided designing. To implement automated search for design solutions, it is proposed to develop the computing facilities, the application of which will significantly increase the productivity of the designer and reduce the complexity of designing. Methods of structural and parametric optimization have been adopted as the basis of the computing facilities. Their efficiency in the synthesis of design solutions is shown, also the schemes, that illustrate and explain the introduction of structural optimization in the traditional design of steel frames, are constructed. To solve the problem of synthesis and comparison of design solutions for steel frames, it is proposed to develop the computing facilities that significantly reduces the complexity of search designing and based on the use of methods of structural and parametric optimization.

  13. Survey the of building and dietary structure of local residents around Yangjiang and Hongyanhe nuclear power plants

    International Nuclear Information System (INIS)

    Qian Yekan; Lei Cuiping; Sun Quanfu; Fan Yaohua; Huang Zhibiao; Cui Yong

    2011-01-01

    Objective: To provide a guide in the course of the daily operation and accident emergency response. Methods: The survey was conducted with questionnaires among heads of households collected by stratified radom sampling. The head of a household was asked about residential type and structure, the sources of drinking water, milk, type and frequency of main vegetables. Results: Two-storied and more than two-storied houses were dominant around Yangjiang nuclear power plant, single-storey houses and tile-roofed houses were dominant around Hongyanhe nuclear power plant. The top three of wall construction materials around the two nuclear power plants were orderly brick, stone and beton. Glass window shelters were in the majority. Drinking water of residents was mainly from wells and waterworks. Milk comes from nonlocal packaged products. The top five high frequency vegetables the residents around Yangjiang nuclear power plants eat were orderly cabbage, zucchini, string beans, tong dish, cucumber, and those around Yangjiang nuclear power plant were orderly chinese cabbage, leek, celery, cabbage, spinach. Conclusion: Building and dietary structure around Yangjiang and Hongyanhe nuclear power plants are incongruence. Government can make decisions to collect foods for nuclides monitoring according to building and dietary structure baseline data, and take emergency measures to direct nuclear safety radiation protection for residents when nuclear accident takes place. (authors)

  14. Routing Corners of Building Structures - by the Method of Vector Addition - Measured with RTN GNSS Surveying Technology

    Science.gov (United States)

    Krzyżek, Robert

    2015-12-01

    The paper deals with the problem of surveying buildings in the RTN GNSS mode using modernized indirect methods of measurement. As a result of the classical realtime measurements using indirect methods (intersection of straight lines or a point on a straight line), we obtain a building structure (a building) which is largely deformed. This distortion is due to the inconsistency of the actual dimensions of the building (tie distances) relative to the obtained measurement results. In order to eliminate these discrepancies, and thus to ensure full consistency of the building geometric structure, an innovative solution was applied - the method of vector addition - to modify the linear values (tie distances) of the external face of the building walls. A separate research problem tackled in the article, although not yet fully solved, is the issue of coordinates of corners of a building obtained after the application of the method of vector addition.

  15. Revised-Confirmatory Survey Report for Portions of the Auxiliary Building Structural Surfaces and Turbine Building Embedded Piping, Rancho Seco Nuclear Generating Station, Herald, California

    International Nuclear Information System (INIS)

    W. C. Adams

    2007-01-01

    During the period of October 15 and 18, 2007, ORISE performed confirmatory radiological survey activities which included beta and gamma structural surface scans and beta activity direct measurements within the Auxiliary Building, beta or gamma scans within Turbine Building embedded piping, beta activity determinations within Turbine Building Drain 3-1-27, and gamma scans and the collection of a soil sample from the clay soils adjacent to the Lower Mixing Box

  16. Historic Structure Assessment for Building 839, Carlisle Barracks: Carlisle, Pennsylvania

    Science.gov (United States)

    2017-10-01

    Restoration Reconstruction Stabilization Condition Assessment Standard Definitions Qualitative Condition Ratings Maintenance Deficiency Priority...Structure Name Building 839 Other Name(s) Farmhouse Location Patton Road Carlisle Barracks Cumberland County, Pennsylvania Date of Construction ca...that guide the project; 4. Condition Assessment Survey: architectural fabric survey and assessment, summary of condition ratings, and maintenance

  17. Forecasting ofuseful life of the structures of a production building during operation

    Directory of Open Access Journals (Sweden)

    Pshenichkina Valeriya

    2017-01-01

    Full Text Available The article presents a probabilistic concept of practical evaluation of the individual resource of structures of industrial buildings and structures in operation. The results of calculation of a monolithic reinforced concrete overpass for safety and durability are given. The quantitative values of the resource are obtained for a given security of operability.

  18. Neutron radiography for the characterization of porous structure in degraded building stones

    International Nuclear Information System (INIS)

    Barone, G; Mazzoleni, P; Raneri, S; Crupi, V; Longo, F; Majolino, D; Venuti, V; Teixeira, J

    2014-01-01

    As it is well known, the porous structure of stones can change due to different degradation processes that modify the characteristics of freshly quarried blocks. Their knowledge is fundamental for predicting the behavior of stones and the efficacy of conservative treatments. In this context, neutron radiography is a useful tool not only to visualize the structure of porous materials, but also to evaluate the degree of degradation and surface modifications resulting from weathering processes. Furthermore, since thermal neutrons suffer a strong attenuation by hydrogen, this technique is effective in order to investigate the amount of absorbed water in building materials. In the present work, we report a neutron radiography investigation of limestones cropping out in the South-Eastern Sicily and widely used as building stones in Baroque monuments of the Noto Valley. The analyzed samples have been submitted to cyclic salt crystallization that simulate degradation processes acting in exposed stones of buildings. The obtained results demonstrate the interest of neutron radiography to better understand deterioration processes in limestones and to acquire information useful for restoration projects

  19. Seismic safety margins research program. Phase I final report - Major structure response (Project IV)

    International Nuclear Information System (INIS)

    Benda, B.J.; Johnson, J.J.; Lo, T.Y.

    1981-08-01

    The primary task of the Major Structure Response Project within the Seismic Safety Margins Research Program (SSMRP) was to develop detailed finite element models of the Zion Nuclear Power Plant's containment building and auxiliary-fuel-turbine (AFT) complex. The resulting models served as input to the seismic methodology analysis chain. The containment shell was modeled as a series of beam elements with the shear and bending characteristics of a circular cylindrical shell. Masses and rotary inertias were lumped at nodal points; thirteen modes were included in the analysis. The internal structure was modeled with three-dimensional finite elements, with masses again lumped at selected nodes; sixty modes were included in the analysis. The model of the AFT complex employed thin plate and shell elements to represent the concrete shear walls and floor diaphragms, and beam and truss elements to model the braced frames. Because of the size and complexity of the model, and the potentially large number of degrees of freedom, masses were lumped at a limited number of node points. These points were selected so as to minimize the effect of the discrete mass distribution on structural response. One hundred and thirteen modes were extracted. A second objective of Project IV was to investigate the effects of uncertainty and variability on structural response. To this end, four side studies were conducted. Three of them, briefly summarized in this volume, addressed themselves respectively to an investigation of sources of random variability in the dynamic response of nuclear power plant structures; formulation of a methodology for modeling and evaluating the effects of structural uncertainty on predicted modal characteristics of major nuclear power plant structures and substructures; and a preliminary evaluation of nonlinear responses in shear-wall structures. A fourth side study, reported in detail in this volume, quantified variations in dynamic characteristics and seismic

  20. Evaluation of Structural Robustness against Column Loss: Methodology and Application to RC Frame Buildings.

    Science.gov (United States)

    Bao, Yihai; Main, Joseph A; Noh, Sam-Young

    2017-08-01

    A computational methodology is presented for evaluating structural robustness against column loss. The methodology is illustrated through application to reinforced concrete (RC) frame buildings, using a reduced-order modeling approach for three-dimensional RC framing systems that includes the floor slabs. Comparisons with high-fidelity finite-element model results are presented to verify the approach. Pushdown analyses of prototype buildings under column loss scenarios are performed using the reduced-order modeling approach, and an energy-based procedure is employed to account for the dynamic effects associated with sudden column loss. Results obtained using the energy-based approach are found to be in good agreement with results from direct dynamic analysis of sudden column loss. A metric for structural robustness is proposed, calculated by normalizing the ultimate capacities of the structural system under sudden column loss by the applicable service-level gravity loading and by evaluating the minimum value of this normalized ultimate capacity over all column removal scenarios. The procedure is applied to two prototype 10-story RC buildings, one employing intermediate moment frames (IMFs) and the other employing special moment frames (SMFs). The SMF building, with its more stringent seismic design and detailing, is found to have greater robustness.

  1. Power systems and electromagnetic safety in of powerful utility buildings and structures

    Directory of Open Access Journals (Sweden)

    О.І. Запорожець

    2008-01-01

    Full Text Available  Researching of origin terms of electromagnetic contaminations from the unbalanced currents and leak currents in the industrial networks of electric supply of structures and buildings saturated energy.

  2. Structural and containment response to LMFBR accidents

    International Nuclear Information System (INIS)

    Marchaterre, J.F.; Fistedis, S.H.; Baker, L. Jr.; Stepnewski, D.D.; Peak, R.D.; Gluekler, E.L.

    1978-01-01

    The results of current developments in analysing the response of reactor structures and containment to LMFBR accidents are presented. The current status of analysis of the structural response of LMFBR's to core disruptive accidents, including head response, potential missile generation and the effects of internal structures are presented. The results of recent experiments to help clarify the thermal response of reactor structures to molten core debris are summarized, including the use of this data to calculate the response of the secondary containment. (author)

  3. MUNI Ways and Structures Building Integrated Solar Membrane Project

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Randall

    2014-07-03

    The initial goal of the MUNI Ways and Structures Building Integrated Solar Membrane Installation Project was for the City and County of San Francisco (CCSF) to gain experience using the integrated higher efficiency solar photovoltaic (PV) single-ply membrane product, as it differs from the conventional, low efficiency, thin-film PV products, to determine the feasibility of success of larger deployment. As several of CCSF’s municipal rooftops are constrained with respect to weight restrictions, staff of the Energy Generation Group of the San Francisco Public Utilities Commission (SFPUC) proposed to install a solar PV system using single-ply membrane The installation of the 100 kW (DC-STC) lightweight photo voltaic (PV) system at the MUNI Ways and Structures Center (700 Pennsylvania Ave., San Francisco) is a continuation of the commitment of the City and County of San Francisco (CCSF) to increase the pace of municipal solar development, and serve its municipal facilities with clean renewable energy. The fourteen (14) solar photovoltaic systems that have already been installed at CCSF municipal facilities are assisting in the reduction of fossil-fuel use, and reduction of greenhouse gases from fossil combustion. The MUNI Ways & Structures Center roof has a relatively low weight-bearing capacity (3.25 pounds per square foot) and use of traditional crystalline panels was therefore rejected. Consequently it was decided to use the best available highest efficiency Building-Integrated PV (BIPV) technology, with consideration for reliability and experience of the manufacturer which can meet the low weight-bearing capacity criteria. The original goal of the project was to provide an opportunity to monitor the results of the BIPV technology and compare these results to other City and County of San Francisco installed PV systems. The MUNI Ways and Structures Center was acquired from the Cookson Doors Company, which had run the Center for many decades. The building was

  4. The thermal impact of subsurface building structures on urban groundwater resources - A paradigmatic example.

    Science.gov (United States)

    Epting, Jannis; Scheidler, Stefan; Affolter, Annette; Borer, Paul; Mueller, Matthias H; Egli, Lukas; García-Gil, Alejandro; Huggenberger, Peter

    2017-10-15

    Shallow subsurface thermal regimes in urban areas are increasingly impacted by anthropogenic activities, which include infrastructure development like underground traffic lines as well as industrial and residential subsurface buildings. In combination with the progressive use of shallow geothermal energy systems, this results in the so-called subsurface urban heat island effect. This article emphasizes the importance of considering the thermal impact of subsurface structures, which commonly is underestimated due to missing information and of reliable subsurface temperature data. Based on synthetic heat-transport models different settings of the urban environment were investigated, including: (1) hydraulic gradients and conductivities, which result in different groundwater flow velocities; (2) aquifer properties like groundwater thickness to aquitard and depth to water table; and (3) constructional features, such as building depths and thermal properties of building structures. Our results demonstrate that with rising groundwater flow velocities, the heat-load from building structures increase, whereas down-gradient groundwater temperatures decrease. Thermal impacts on subsurface resources therefore have to be related to the permeability of aquifers and hydraulic boundary conditions. In regard to the urban settings of Basel, Switzerland, flow velocities of around 1 md -1 delineate a marker where either down-gradient temperature deviations or heat-loads into the subsurface are more relevant. Furthermore, no direct thermal influence on groundwater resources should be expected for aquifers with groundwater thicknesses larger 10m and when the distance of the building structure to the groundwater table is higher than around 10m. We demonstrate that measuring temperature changes down-gradient of subsurface structures is insufficient overall to assess thermal impacts, particularly in urban areas. Moreover, in areas which are densely urbanized, and where groundwater flow

  5. Climate-responsive design : A framework for an energy concept design-decision support tool for architects using principles of climate-responsive design

    NARCIS (Netherlands)

    Looman, R.H.J.

    2017-01-01

    In climate-responsive design the building becomes an intermediary in its own energy housekeeping, forming a link between the harvest of climate resources and low-energy provision of comfort. Essential here is the employment of climate-responsive building elements; structural and architectural

  6. Structural observability analysis and EKF based parameter estimation of building heating models

    Directory of Open Access Journals (Sweden)

    D.W.U. Perera

    2016-07-01

    Full Text Available Research for enhanced energy-efficient buildings has been given much recognition in the recent years owing to their high energy consumptions. Increasing energy needs can be precisely controlled by practicing advanced controllers for building Heating, Ventilation, and Air-Conditioning (HVAC systems. Advanced controllers require a mathematical building heating model to operate, and these models need to be accurate and computationally efficient. One main concern associated with such models is the accurate estimation of the unknown model parameters. This paper presents the feasibility of implementing a simplified building heating model and the computation of physical parameters using an off-line approach. Structural observability analysis is conducted using graph-theoretic techniques to analyze the observability of the developed system model. Then Extended Kalman Filter (EKF algorithm is utilized for parameter estimates using the real measurements of a single-zone building. The simulation-based results confirm that even with a simple model, the EKF follows the state variables accurately. The predicted parameters vary depending on the inputs and disturbances.

  7. Effects of reinforcement ratio and arrangement on the structural behavior of a nuclear building under aircraft impact

    International Nuclear Information System (INIS)

    Thai, Duc-Kien; Kim, Seung-Eock; Lee, Hyuk-Kee

    2014-01-01

    Highlights: • Numerical analysis of RC nuclear building model under aircraft impact was conducted. • The analysis result shows similar behavior as compared to the Riera function. • The effects of reinforcement ratio and arrangement were enumerated. • The appropriate number of layer of longitudinal rebar was recommended. - Abstract: This study presents the effectiveness of the rebar ratio and the arrangement of reinforced concrete (RC) structures on the structural behavior of nuclear buildings under aircraft impact using a finite element (FE) approach. A simplified model of a fictitious nuclear building using RC structures was fully modeled. The aircraft model of a Boeing 767-400 was used for impact simulation and was developed and verified with a conventional impact force–time history curve. The IRIS Punching test was used to validate the damage prediction capabilities of the RC wall under impact loading. With regard to the different rebar ratios and rebar arrangements of a nuclear RC building, the structural behavior of a building under aircraft impact was investigated. The structural behavior investigated included plastic deformation, displacement, energy dissipation, perforation/penetration depth and scabbing area. The results showed that the rebar ratio has a significant effect on withstanding aircraft impact and reducing local damage. With four layers of rebar, the RC wall absorbed and dissipated the impact energy more than once with only two layers of rebar for the same rebar ratio

  8. On the prediction of building damage from ground motion

    Energy Technology Data Exchange (ETDEWEB)

    Blume, John A [John A. Blume and Associates Research Division, San Francisco, CA (United States)

    1970-05-15

    In the planning of a nuclear event it is essential to consider the effects of the expected ground motion on all exposed buildings and other structures. There are various steps and procedures in this process which generally increase in scope and refinement as the preparations advance. Initial, rough estimates, based upon rules-of-thumb and preliminary predictions of ground motion and structural response, may be adequate to show general feasibility of the project. Subsequent work is done in both the field and analysis phases, to estimate the total structure exposure, to isolate special hazards, and to make damage cost estimates. Finally, specific analyses are made of special buildings or structures to identify safety problems and to make recommendations for safety measures during the proposed event. Because the ground motion and the structural response both involve many random variables and therefore some uncertainties in prediction, the probabilistic aspects must be considered, both on a broad statistical basis and for specific safety considerations. Decisions must be made as to the acceptability or non-acceptability of the risks and any indicated procedures before and during the event to reduce or to eliminate the risks. The paper discusses various techniques involved in these operations including the Spectral Matrix Method of damage prediction, the Threshold Evaluation Scale for specific building analysis, and the inelastic and probabilistic aspects of the problem. (author)

  9. On the prediction of building damage from ground motion

    International Nuclear Information System (INIS)

    Blume, John A.

    1970-01-01

    In the planning of a nuclear event it is essential to consider the effects of the expected ground motion on all exposed buildings and other structures. There are various steps and procedures in this process which generally increase in scope and refinement as the preparations advance. Initial, rough estimates, based upon rules-of-thumb and preliminary predictions of ground motion and structural response, may be adequate to show general feasibility of the project. Subsequent work is done in both the field and analysis phases, to estimate the total structure exposure, to isolate special hazards, and to make damage cost estimates. Finally, specific analyses are made of special buildings or structures to identify safety problems and to make recommendations for safety measures during the proposed event. Because the ground motion and the structural response both involve many random variables and therefore some uncertainties in prediction, the probabilistic aspects must be considered, both on a broad statistical basis and for specific safety considerations. Decisions must be made as to the acceptability or non-acceptability of the risks and any indicated procedures before and during the event to reduce or to eliminate the risks. The paper discusses various techniques involved in these operations including the Spectral Matrix Method of damage prediction, the Threshold Evaluation Scale for specific building analysis, and the inelastic and probabilistic aspects of the problem. (author)

  10. Climate Responsive Buildings Concepts in Hong Kong

    DEFF Research Database (Denmark)

    Haase, M.; Amato, A.; van der Aa, A.

    2006-01-01

    There is a global need for a more sustainable building development. About 50% of energy is used in buildings indicating that buildings provide a considerable potential for operational energy savings. Studies were conducted with the following objectives: to perform a state-of-the-art review...... energy saving installations are increasingly applied as heat pumps in combination with energy storage, balanced ventilation with heat recovery, cooling towers etc. In Hong Kong in most cases there is no integrated design process for building projects. This means that projects are developed and designed...

  11. Seismic response and fragility evaluation for an Eastern US NPP including soil-structure interaction effects

    International Nuclear Information System (INIS)

    Ghiocel, Dan M.; Wilson, Paul R.; Thomas, Gary G.; Stevenson, John D.

    1998-01-01

    The paper discusses methodological aspects involved in a probabilistic seismic soil-structure interaction (SSI) analysis for a Seismic Probabilistic Risk Assessment (SPRA) review. An example of an Eastern US nuclear power plant (NPP) is presented. The approach presented herein follows the current practice of the Individual Plant Examination for External Events (IPEEE) program in the US. The NPP is founded on a relatively soft soil deposit, and thus the SSI effects on seismic responses are significant. Probabilistic models used for the idealization of the seismic excitation and the surrounding soil deposit are described. Using a lognormal format, computed random variability effects were combined with those proposed in the SPRA methodology guidelines. Probabilistic floor response spectra and structural fragilities for different NPP buildings were computed. Structural capacities were determined following the current practice which assumes independent median safety factors for strength and inelastic absorption. Limitations of the IPEEE practice for performing SPRA are discussed and alternate procedures, more rigorous and simple to implement, are suggested

  12. Automated Demand Response Technology Demonstration Project for Small and Medium Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Page, Janie; Kiliccote, Sila; Dudley, Junqiao Han; Piette, Mary Ann; Chiu, Albert K.; Kellow, Bashar; Koch, Ed; Lipkin, Paul

    2011-07-01

    Small and medium commercial customers in California make up about 20-25% of electric peak load in California. With the roll out of smart meters to this customer group, which enable granular measurement of electricity consumption, the investor-owned utilities will offer dynamic prices as default tariffs by the end of 2011. Pacific Gas and Electric Company, which successfully deployed Automated Demand Response (AutoDR) Programs to its large commercial and industrial customers, started investigating the same infrastructures application to the small and medium commercial customers. This project aims to identify available technologies suitable for automating demand response for small-medium commercial buildings; to validate the extent to which that technology does what it claims to be able to do; and determine the extent to which customers find the technology useful for DR purpose. Ten sites, enabled by eight vendors, participated in at least four test AutoDR events per site in the summer of 2010. The results showed that while existing technology can reliably receive OpenADR signals and translate them into pre-programmed response strategies, it is likely that better levels of load sheds could be obtained than what is reported here if better understanding of the building systems were developed and the DR response strategies had been carefully designed and optimized for each site.

  13. Response of subsystems on inelastic structures

    International Nuclear Information System (INIS)

    Lin, J.; Mahin, S.A.

    1984-01-01

    Preliminary analysis are performed to obtain insight into the seismic response of subsystems supported on simple structures that yield during severe earthquake ground motions. Current design recommendations for subsystems accounting for yielding of the supporting structures are assessed and found to be unconservative. An amplification factor is defined to quantify the effects of inelastic deformations of the supporting structure on subsystem response. Design guidelines are formulated for predicting the amplification factor based on statistical evaluation of the results generated for ten earthquake ground motions. Using these values, design floor response spectra can be obtained from conventional linear elastic floor response spectra accounting for yielding of the supporting structure without having to perform inelastic analysis. The effects of non-zero subsystem mass are examined. The recommended amplification factors are found to be applicable even when the mass of subsystem approaches that of the supporting structure

  14. Seismic fragility analysis of a nuclear building based on probabilistic seismic hazard assessment and soil-structure interaction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, R.; Ni, S.; Chen, R.; Han, X.M. [CANDU Energy Inc, Mississauga, Ontario (Canada); Mullin, D. [New Brunswick Power, Point Lepreau, New Brunswick (Canada)

    2016-09-15

    Seismic fragility analyses are conducted as part of seismic probabilistic safety assessment (SPSA) for nuclear facilities. Probabilistic seismic hazard assessment (PSHA) has been undertaken for a nuclear power plant in eastern Canada. Uniform Hazard Spectra (UHS), obtained from the PSHA, is characterized by high frequency content which differs from the original plant design basis earthquake spectral shape. Seismic fragility calculations for the service building of a CANDU 6 nuclear power plant suggests that the high frequency effects of the UHS can be mitigated through site response analysis with site specific geological conditions and state-of-the-art soil-structure interaction analysis. In this paper, it is shown that by performing a detailed seismic analysis using the latest technology, the conservatism embedded in the original seismic design can be quantified and the seismic capacity of the building in terms of High Confidence of Low Probability of Failure (HCLPF) can be improved. (author)

  15. Time versus frequency domain calculation of the main building complex of the VVER 440/213 NPP PAKS

    International Nuclear Information System (INIS)

    Katona, T.; Ratkai, S.; Halbritter, A.; Krutzik, N.J.; Schuetz, W.

    1995-01-01

    Various dynamic analyses were conducted for the main building complex of the VVER 440/213 PAKS in order to determine the dynamic response and assess the aseismic capacity of this nuclear power plant. Different types of mathematical models for idealizing the soil and the building structures were used. The main goal of the study presented here was to demonstrate the effects of different procedures for consideration of soil-structure interaction on the dynamic response of the structures mentioned above. The analyses were based on appropriate mathematical models of the coupled vibration structures (reactor building, turbine hall, intermediate building structures) and the layered soil. On the basis of this study, it can be concluded that substructure models using frequency-independent impedances and cut-off of modal damping usually provide conservative results. Complex models which allow the soil-soil and the structure or by frequency-dependent impedances) provide more accurate results. The latter approach results in more efficient designs which are not only safe but also economical. (author). 7 refs., 15 figs

  16. Non-destructive evaluation of timber structures in a historical building of Tiradentes , MG

    Directory of Open Access Journals (Sweden)

    Luciana Barbosa de Abreu

    2013-09-01

    Full Text Available Problems related to the durability of wood are commonly found in historical buildings structures. Preservation and conservation resolutions must be adopted, in order to avoid losses and substitutions, which mischaracterize buildings. Non-destructive methods for detecting deterioration should be used in order to substantiate decisions and increase the longevity of historical heritage. This work was carried out in order to perform non-destructive essays to infer about the integrity of a beam and a pillar of the original construction of the Sobrado Ramalho, a historical building of the city of Tiradentes, MG. The equipments utilized were the Stress Wave Timer and resistograph. Samples of the elements were taken for analysis of density. The results showed that, in both structures, to calculate the dynamic modulus of elasticity, there was no significant difference for the application of stress wave timer on the alignments studied. There was no significant difference between the directions of application of the resistograph on the pillar, due to its apparent entirety and regular sessions, practically square, and to not being loaded eccentrically. In the case of the beam, there was significant difference, presumably because it has cracks in its traction line. The equipments, unknown by professionals of heritage conservation allow promising methodologies for inspection of timber structures in service.

  17. Condition Assessment of the Timber Structures of a Century-Old Industrial Building Using a Nondestructive Inspection Procedure

    Science.gov (United States)

    Xiping Wang; Marko Teder; James Wacker

    2013-01-01

    This paper reports an in situ inspection project conducted on heavy timber structures of a century-old industrial building at a paper manufacturing facility. A nondestructive inspection procedure was employed to evaluate the true condition of the heavy timbers that serve as the main framing structure of the building. The on-site investigation involved monitoring of the...

  18. Responses of a 58-story RC dual core shear wall and outrigger frame building inferred from two earthquakes

    Science.gov (United States)

    Çelebi, Mehmet

    2016-01-01

    Responses of a dual core shear-wall and outrigger-framed 58-story building recorded during the Mw6.0 Napa earthquake of 24 August 2014 and the Mw3.8 Berkeley earthquake of 20 October 2011 are used to identify its dynamic characteristics and behavior. Fundamental frequencies are 0.28 Hz (NS), 0.25 Hz (EW), and 0.43 Hz (torsional). Rigid body motions due to rocking are not significant. Average drift ratios are small. Outrigger frames do not affect average drift ratios or mode shapes. Local site effects do not affect the response; however, response associated with deeper structure may be substantial. A beating effect is observed from data of both earthquakes but beating periods are not consistent. Low critical damping ratios may have contributed to the beating effect. Torsion is relatively larger above outriggers as indicated by the time-histories of motions at the roof, possibly due to the discontinuity of the stiffer shear walls above level 47.

  19. Floor response spectra of the main process building of a reprocessing plant against earthquake, airplane crash and blast

    International Nuclear Information System (INIS)

    Hilpert, H.J.

    1987-01-01

    In the general concept of the planned reprocessing plant for spent fuel elements, the main process building has the central function. This building will be designed to withstand earthquake, airplane crash and blast. This report deals with the stress on components and systems due to vibration of the building, the floor response spectra

  20. Structural pounding of concrete frame structure with masonry infill wall under seismic loading

    Science.gov (United States)

    Ismail, Rozaina; Hasnan, Mohd Hafizudin; Shamsudin, Nurhanis

    2017-10-01

    Structural pounding is additional problem than the other harmful damage that may occurs due to the earthquake vibrations. A lot of study has been made by past researcher but most of them did not include the walls. The infill masonry walls are rarely involved analysis of structural systems but it does contribute to earthquake response of the structures. In this research, a comparison between adjacent building of 10-storey and 7-storey concrete frame structure without of masonry infill walls and the same dynamic properties of buildings. The diagonal strut approach is adopted for modeling masonry infill walls. This research also focused on finding critical building separation in order to prevent the adjacent structures from pounding. LUSAS FEA v14.03 software has been used for modeling analyzing the behavior of structures due to seismic loading and the displacement each floor of the building has been taken in order to determine the critical separation distance between the buildings. From the analysis that has been done, it is found that masonry infill walls do affect the structures behavior under seismic load. Structures without masonry infill walls needs more distance between the structures to prevent structural pounding due to higher displacement of the buildings when it sways under seismic load compared to structures with masonry infill walls. This shows that contribution of masonry infill walls to the analysis of structures cannot be neglected.

  1. Mobile augmented reality in support of building damage and safety assessment

    Science.gov (United States)

    Kim, W.; Kerle, N.; Gerke, M.

    2016-02-01

    Rapid and accurate assessment of the state of buildings in the aftermath of a disaster event is critical for an effective and timely response. For rapid damage assessment of buildings, the utility of remote sensing (RS) technology has been widely researched, with focus on a range of platforms and sensors. However, RS-based approaches still have limitations to assess structural integrity and the specific damage status of individual buildings. Structural integrity refers to the ability of a building to hold the entire structure. Consequently, ground-based assessment conducted by structural engineers and first responders is still required. This paper demonstrates the concept of mobile augmented reality (mAR) to improve performance of building damage and safety assessment in situ. Mobile AR provides a means to superimpose various types of reference or pre-disaster information (virtual data) on actual post-disaster building data (real buildings). To adopt mobile AR, this study defines a conceptual framework based on the level of complexity (LOC). The framework consists of four LOCs, and for each of these, the data types, required processing steps, AR implementation and use for damage assessment are described. Based on this conceptualization we demonstrate prototypes of mAR for both indoor and outdoor purposes. Finally, we conduct a user evaluation of the prototypes to validate the mAR approach for building damage and safety assessment.

  2. Life-Cycle Assessment of Seismic Retrofit Strategies Applied to Existing Building Structures

    Directory of Open Access Journals (Sweden)

    Umberto Vitiello

    2016-12-01

    Full Text Available In the last few years, the renovation and refurbishment of existing buildings have become the main activities of the construction industry. In particular, many studies have recently focused on the mechanical and energy performances of existing retrofitted/refurbished facilities, while some research has addressed the environmental effects of such operations. The present study aims to assess the environmental impact of some retrofit interventions on an existing reinforced concrete (RC building. Once the structural requirements have been satisfied and the environmental effects of these retrofit solutions defined, the final purpose of this study is to identify the most environmentally sustainable retrofit strategy. The environmental impact of the structural retrofit options is assessed using a life-cycle assessment (LCA. This paper sets out a systematic approach that can be adopted when choosing the best structural retrofit option in terms of sustainability performance. The final aim of the study is to also provide a tool for researchers and practitioners that reflects a deep understanding of the sustainability aspects of retrofit operations and can be used for future researches or practical activities.

  3. Presence of microplastics in the tube structure of the reef-building ...

    African Journals Online (AJOL)

    The prevalence of microplastics in the marine environment has resulted in a need to understand their association with various fauna. The aim of this study was to assess whether microplastic particles are present in the tube structure of the indigenous reef-building polychaete Gunnarea gaimardi, which occurs along the ...

  4. Relations between constructive peculiarities and structural behavior in Venice buildings

    Directory of Open Access Journals (Sweden)

    Doglioni, F.

    2012-12-01

    Full Text Available Here we are synthetically describing some constructive peculiarities of Venice civil buildings, analyzing the relation with the features of their structural decay and behavior in the long run. We suppose Venetian buildings, especially those parts which are conceived to suit the lagoon environment, to have undergone an evolution made of some adjustments, which were based on the observation of damages in previous buildings. That is we suppose ancient builders to rely on their awareness of the behavior of structures yet to come, and to be able to forecast it in part. This process brought some building contrivances to perfection, as exclusive and enduring features of Venice, overcoming changes in style and architectural layout, till they grew into essential elements of a whole and adaptable “device”. This writing is meant for a concise interpretation of this device, which is the result of some research works carried out at Venice IUAV University.

    En este texto, se describen sintéticamente algunas peculiaridades de la edificación residencial de Venecia, analizando su relación con el abanico de problemas estructurales que caracterizan el comportamiento estructural del edificio a lo largo del tiempo. Se aventura la hipótesis que las construcciones venecianas y, en particular, algunos de sus detalles, concebidos específicamente para la laguna donde se enclava, han sido objeto de una adaptación evolutiva a través de la observación de los problemas estructurales de los edificios precedentes. Los alarifes venecianos aprendieron a tener en cuenta el comportamiento estructural posterior del edificio, que previeron en cierta medida. Este proceso ha llevado a perfeccionar algunos detalles constructivos exclusivos de Venecia que han perdurado en el tiempo, que han resistido impertérritos a mutaciones de estilo y de configuración arquitectónica, hasta constituir elementos esenciales de un aparato indivisible y adaptable cuya interpretaci

  5. Feasibility study tool for semi-rigid joints design of high-rise buildings steel structures

    Science.gov (United States)

    Bagautdinov, Ruslan; Monastireva, Daria; Bodak, Irina; Potapova, Irina

    2018-03-01

    There are many ways to consider the final cost of the high-rise building structures and to define, which of their different variations are the most effective from different points of view. The research of Jaakko Haapio is conducted in Tampere University of Technology, which aims to develop a method that allows determining the manufacturing and installation costs of steel structures already at the tender phase while taking into account their details. This paper is aimed to make the analysis of the Feature-Based Costing Method for skeletal steel structures proposed by Jaakko Haapio. The most appropriate ways to improve the tool and to implement it in the Russian circumstances for high-rise building design are derived. Presented tool can be useful not only for the designers but, also, for the steel structures manufacturing organizations, which can help to utilize BIM technologies in the organization process and controlling on the factory.

  6. EVALUATION OF A FAST-RESPONSE URBAN WIND MODEL - COMPARISON TO SINGLE-BUILDING WIND TUNNEL DATA

    International Nuclear Information System (INIS)

    E.R. PARDYJAK; M.J. BROWN

    2001-01-01

    Prediction of the 3-dimensional flow field around buildings and other obstacles is important for a number of applications, including urban air quality studies, the tracking of plumes from accidental releases of toxic air contaminants, indoor/outdoor air pollution problems, and thermal comfort assessments. Various types of computational fluid dynamics (CFD) models have been used for determining the flow fields around buildings (e.g., Reisner et al., 1998; Eichhorn et al., 1988). Comparisons to measurements show that these models work reasonably well for the most part (e.g., Ehrhard et al., 2 ; Johnson and Hunter, 1998; Murakami, 1997). However, CFD models are computationally intensive and for some applications turn-around time is of the essence. For example, planning and assessment studies in which hundreds of cases must be analyzed or emergency response scenarios in which plume transport must be computed quickly. Several fast-response dispersion models of varying levels of fidelity have been developed to explicitly account for the effects of a single building or groups of buildings (e.g., UDM - Hall et al. (2000), NRC-Ramsdell and Fosmire (1995), CBP-3 - Yamartino and Wiegand (1986), APRAC - Daerdt et al. (1973)). Although a few of these models include the Hotchkiss and Harlow (1973) analytical solution for potential flow in a notch to describe the velocity field within an urban canyon, in general, these models do not explicitly compute the velocity field around groups of buildings. The EPA PRIME model (Schulman et al., 2000) has been empirically derived to provide streamlines around a single isolated building

  7. Vibration isolation of a building against earthquake, airplane crash and blast

    International Nuclear Information System (INIS)

    Mischke, J.; Hilpert, H.J.; Henkel, F.O.

    1986-01-01

    The influence of three different support concepts on the vibration responses of a building to the load cases earthquake, airplane crash and blast is numerically investigated. Compared are the three concepts: the standard version of a double shell structure with a combined base for inner and outer building without isolation system; the same building with isolation system between foundation slab and soil, as vibration isolation known so far; and as a third concept a double shell structure with completely separated inner and outer building, where the isolation system is placed between the two parts of the building. The results show that, compared to the standard concept, the third concept leads to a nearly complete isolation of shock-induced vibrations, and to a reduction of the vibrations caused by an earthquake, comparable to the reduction in the isolation concept known so far. (orig.)

  8. Seismic response analysis of a piping system subjected to multiple support excitations in a base isolated NPP building

    International Nuclear Information System (INIS)

    Surh, Han-Bum; Ryu, Tae-Young; Park, Jin-Sung; Ahn, Eun-Woo; Choi, Chul-Sun; Koo, Ja Choon; Choi, Jae-Boong; Kim, Moon Ki

    2015-01-01

    Highlights: • Piping system in the APR 1400 NPP with a base isolation design is studied. • Seismic response of piping system in base isolated building are investigated. • Stress classification method is examined for piping subjected to seismic loading. • Primary stress of piping is reduced due to base isolation design. • Substantial secondary stress is observed in the main steam piping. - Abstract: In this study, the stress response of the piping system in the advanced power reactor 1400 (APR 1400) with a base isolation design subjected to seismic loading is addressed. The piping system located between the auxiliary building with base isolation and the turbine building with a fixed base is considered since it can be subjected to substantial relative support movement during seismic events. First, the support responses with respect to the base characteristic are investigated to perform seismic analysis for multiple support excitations. Finite element analyses are performed to predict the piping stress response through various analysis methods such as the response spectrum, seismic support movement and time history method. To separately evaluate the inertial effect and support movement effect on the piping stress, the stress is decomposed into a primary and secondary stress using the proposed method. Finally, influences of the base isolation design on the piping system in the APR 1400 are addressed. The primary stress based on the inertial loading is effectively reduced in a base isolation design, whereas a considerable amount of secondary stress is generated in the piping system connecting a base isolated building with a fixed base building. It is also confirmed that both the response spectrum analysis and seismic support movement analysis provide more conservative estimations of the piping stress compared to the time history analysis

  9. Curvilinear steel elements in load-bearing structures of high-rise building spatial frames

    Directory of Open Access Journals (Sweden)

    Ibragimov Alexander

    2018-01-01

    Full Text Available The application of curvilinear elements in load-bearing metal structures of high-rise buildings supposes ensuring of their bearing capacity and serviceability. There may exist a great variety of shapes and orientations of such structural elements. In particular, it may be various flat curves of an open or closed oval profile such as circular or parabolic arch or ellipse. The considered approach implies creating vast internal volumes without loss in the load-bearing capacity of the frame. The basic concept makes possible a wide variety of layout and design solutions. The presence of free internal spaces of large volume in "skyscraper" type buildings contributes to resolving a great number of problems, including those of communicative nature. The calculation results confirm the basic assumptions.

  10. Curvilinear steel elements in load-bearing structures of high-rise building spatial frames

    Science.gov (United States)

    Ibragimov, Alexander; Danilov, Alexander

    2018-03-01

    The application of curvilinear elements in load-bearing metal structures of high-rise buildings supposes ensuring of their bearing capacity and serviceability. There may exist a great variety of shapes and orientations of such structural elements. In particular, it may be various flat curves of an open or closed oval profile such as circular or parabolic arch or ellipse. The considered approach implies creating vast internal volumes without loss in the load-bearing capacity of the frame. The basic concept makes possible a wide variety of layout and design solutions. The presence of free internal spaces of large volume in "skyscraper" type buildings contributes to resolving a great number of problems, including those of communicative nature. The calculation results confirm the basic assumptions.

  11. The Use of the Artificial Damped Outrigger Systems in Tall R.C Buildings Under Seismic Loading

    Directory of Open Access Journals (Sweden)

    Abbas Abd Elmajeed Allawi

    2016-04-01

    Full Text Available This paper studies the combination of fluid viscous dampers in the outrigger system to add supplementary damping into the structure, which purpose to remove the dependability of the structure to lower variable intrinsic damping. This optimizes the accuracy of the dynamic response and by providing higher level of damping, basically minimizes the wanted stiffness of the structure while at the same time optimizing the achievement. The modal considered is a 36 storey square high rise reinforced concrete building. By constructing a discrete lumped mass model and using frequency-based response function, two systems of dampers, parallel and series systems are studied. The maximum lateral load at the top of the building is calculated, and this load will be applied at every floor of the building, giving a conservative solution. For dynamic study Response Spectrum Analysis was conducted and the behavior of the building was determined considering response parameters. MATLAB software, has been used in the dynamic analysis for three modes. For all modes, it is observed that the parallel system of dampers result in lower amplitude of vibration and achieved more efficiently compared to the damper is in series, until the parallel system arrives 100% damping for mode three.

  12. Elfin: An algorithm for the computational design of custom three-dimensional structures from modular repeat protein building blocks.

    Science.gov (United States)

    Yeh, Chun-Ting; Brunette, T J; Baker, David; McIntosh-Smith, Simon; Parmeggiani, Fabio

    2018-02-01

    Computational protein design methods have enabled the design of novel protein structures, but they are often still limited to small proteins and symmetric systems. To expand the size of designable proteins while controlling the overall structure, we developed Elfin, a genetic algorithm for the design of novel proteins with custom shapes using structural building blocks derived from experimentally verified repeat proteins. By combining building blocks with compatible interfaces, it is possible to rapidly build non-symmetric large structures (>1000 amino acids) that match three-dimensional geometric descriptions provided by the user. A run time of about 20min on a laptop computer for a 3000 amino acid structure makes Elfin accessible to users with limited computational resources. Protein structures with controlled geometry will allow the systematic study of the effect of spatial arrangement of enzymes and signaling molecules, and provide new scaffolds for functional nanomaterials. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. ENERGY DEMANDS OF THE EXISTING COLLECTIVE BUILDINGS WITH BEARING STRUCTURE OF LARGE PRECAST CONCRETE PANELS FROM TIMISOARA

    Directory of Open Access Journals (Sweden)

    Pescari S.

    2015-05-01

    Full Text Available One of the targets of EU Directives on the energy performance of buildings is to reduce the energy consumption of the existing buildings by finding efficient solutions for thermal rehabilitation. In order to find the adequate solutions, the first step is to establish the current state of the buildings and to determine their actual energy consumption. The current paper aims to present the energy demands of the existing buildings with bearing structure of large precast concrete panels in the city of Timisoara. Timisoara is one of the most important cities in the west side of Romania, being on the third place in terms of size and economic development. The Census of Population and Housing of 2011 states that Timisoara has about 127841 private dwellings and 60 percent of them are collective buildings. Energy demand values of the existing buildings with bearing structure of large precast concrete panels in Timisoara, in their current condition, are higher than the accepted values provided in the Romanian normative, C107. The difference between these two values can reach up to 300 percent.

  14. Scientific Support of Construction of Unique Buildings and Structures and Facilities of Increased Danger

    Science.gov (United States)

    Alekhin, V. N.; Antipin, A. A.; Gorodilov, S. N.

    2017-11-01

    A range of works on scientific support for the construction of unique buildings and the structures and facilities of increased danger, such as airport facilities, long-span and high-rise buildings is being implemented at the department “Computer Aided Design in Civil Engineering” of Ural Federal University. The scope of work includes: numerical simulation of wind and snow loads, analysis of progressive collapse and seismic impacts, verification of design solutions. The results of wind, snow loads and progressive collapse of airport buildings in the cities of Orenburg, Rostov-on-Don and Perm are considered in the article.

  15. 49 CFR 41.110 - New DOT owned buildings and additions to buildings.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false New DOT owned buildings and additions to buildings....110 New DOT owned buildings and additions to buildings. (a) DOT Operating Administrations responsible for the design and construction of new DOT Federally owned buildings will ensure that each building is...

  16. Proposed Assessment of Dynamic Resistance of the Existing Industrial Portal Frame Building Structures to the Impact of Mining Tremors

    Science.gov (United States)

    Rusek, Janusz; Kocot, Wojciech

    2017-10-01

    The article presents the method for assessing dynamic resistance of the existing industrial portal frame building structures subjected to mining tremors. The study was performed on two industrial halls of a reinforced concrete structure and a steel structure. In order to determine the dynamic resistances of these objects, static and dynamic numerical analysis in the FEA environment was carried out. The scope of numerical calculations was adapted to the guidelines contained in the former and current design standards. This allowed to formulate the criteria, on the basis of which the maximum permissible value of the horizontal ground acceleration was obtained, constituting resistance of the analyzed objects. The permissible range of structural behaviour was determined by comparing the effects of load combinations adopted at the design stage with a seismic combination recognized in Eurocode 8. The response spectrum method was used in the field of dynamic analysis, taking into account the guidelines contained in Eurocode 8 and the guidelines of National. Finally, in accordance with the established procedure, calculations were carried out and the results for the two model portal frame buildings of reinforced concrete and steel structures were presented. The results allowed for the comparison of the dynamic resistance of two different types of material and design, and a sensitivity analysis with respect to their constituent bearing elements. The conclusions drawn from these analyses helped to formulate the thesis for the next stage of the research, in which it is expected to analyze a greater number of objects using a parametric approach, in relation to the geometry and material properties.

  17. Feasibility study tool for semi-rigid joints design of high-rise buildings steel structures

    Directory of Open Access Journals (Sweden)

    Bagautdinov Ruslan

    2018-01-01

    Full Text Available There are many ways to consider the final cost of the high-rise building structures and to define, which of their different variations are the most effective from different points of view. The research of Jaakko Haapio is conducted in Tampere University of Technology, which aims to develop a method that allows determining the manufacturing and installation costs of steel structures already at the tender phase while taking into account their details. This paper is aimed to make the analysis of the Feature-Based Costing Method for skeletal steel structures proposed by Jaakko Haapio. The most appropriate ways to improve the tool and to implement it in the Russian circumstances for high-rise building design are derived. Presented tool can be useful not only for the designers but, also, for the steel structures manufacturing organizations, which can help to utilize BIM technologies in the organization process and controlling on the factory.

  18. Maintenance of Heritage Building: A Case Study from Ipoh, Malaysia

    Directory of Open Access Journals (Sweden)

    Tan Seong Yeow

    2016-01-01

    Full Text Available Heritage buildings represent the tangible cultural heritage of a community. However, many of the heritage buildings have being left neglected. Ipoh as a city rich in heritage, has many dilapidated heritage buildings which are experiencing a resurging interest. However, the problems faced by many owners are the lack of technical information of such buildings, leading to premature abandonment and demolition. Therefore, the objectives of this study are to determine the types and extent of defects present in the building studied. To achieve these objectives, a case study of a century old heritage property in Ipoh, Perak was conducted. The study aims to provide reference to owners and those responsible for the conservation of heritage buildings with similar conditions to identify and prioritize critical defects in relation to the building life span to determine its condition. The findings determined the probable causes of defects such as settlement and façade cracks, which are over 30 years old, were attributed to leaking plumbing pipes, rainwater ingress and the construction of an adjacent 20 story apartment building. The major issues to address were stabilizing the foundation through cement grouting, reinforcing the existing structural systems and roof systems as well as arresting the decay of timber floor structure. In conclusion, major maintenance guidelines are need to address structural issues and weather tightness of the building envelope, especially its roof and drainage systems.

  19. Incoherent SSI Analysis of Reactor Building using 2007 Hard-Rock Coherency Model

    International Nuclear Information System (INIS)

    Kang, Joo-Hyung; Lee, Sang-Hoon

    2008-01-01

    Many strong earthquake recordings show the response motions at building foundations to be less intense than the corresponding free-field motions. To account for these phenomena, the concept of spatial variation, or wave incoherence was introduced. Several approaches for its application to practical analysis and design as part of soil-structure interaction (SSI) effect have been developed. However, conventional wave incoherency models didn't reflect the characteristics of earthquake data from hard-rock site, and their application to the practical nuclear structures on the hard-rock sites was not justified sufficiently. This paper is focused on the response impact of hard-rock coherency model proposed in 2007 on the incoherent SSI analysis results of nuclear power plant (NPP) structure. A typical reactor building of pressurized water reactor (PWR) type NPP is modeled classified into surface and embedded foundations. The model is also assumed to be located on medium-hard rock and hard-rock sites. The SSI analysis results are obtained and compared in case of coherent and incoherent input motions. The structural responses considering rocking and torsion effects are also investigated

  20. Secure Utilization of Beacons and UAVs in Emergency Response Systems for Building Fire Hazard.

    Science.gov (United States)

    Seo, Seung-Hyun; Choi, Jung-In; Song, Jinseok

    2017-09-25

    An intelligent emergency system for hazard monitoring and building evacuation is a very important application area in Internet of Things (IoT) technology. Through the use of smart sensors, such a system can provide more vital and reliable information to first-responders and also reduce the incidents of false alarms. Several smart monitoring and warning systems do already exist, though they exhibit key weaknesses such as a limited monitoring coverage and security, which have not yet been sufficiently addressed. In this paper, we propose a monitoring and emergency response method for buildings by utilizing beacons and Unmanned Aerial Vehicles (UAVs) on an IoT security platform. In order to demonstrate the practicability of our method, we also implement a proof of concept prototype, which we call the UAV-EMOR (UAV-assisted Emergency Monitoring and Response) system. Our UAV-EMOR system provides the following novel features: (1) secure communications between UAVs, smart sensors, the control server and a smartphone app for security managers; (2) enhanced coordination between smart sensors and indoor/outdoor UAVs to expand real-time monitoring coverage; and (3) beacon-aided rescue and building evacuation.

  1. 49 CFR 1242.26 - Miscellaneous building and structures (account XX-19-28).

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Miscellaneous building and structures (account XX... XX-19-28). Separate common expenses as specific facts indicate or according to distribution of common expenses listed in § 1242.10, Administration-Track (account XX-19-02). ...

  2. A Framework for Occupancy Tracking in a Building via Structural Dynamics Sensing of Footstep Vibrations

    Directory of Open Access Journals (Sweden)

    Jeffrey D. Poston

    2017-11-01

    Full Text Available Counting the number of occupants in building areas over time—occupancy tracking—provides valuable information for responding to emergencies, optimizing thermal conditions or managing personnel. This capability is distinct from tracking individual building occupants as they move within a building, has lower complexity than conventional tracking algorithms require, and avoids privacy concerns that tracking individuals may pose. The approach proposed here is a novel combination of data analytics applied to measurements from a building’s structural dynamics sensors (e.g., accelerometers or geophones. Specifically, measurements of footstep-generated structural waves provide evidence of occupancy in a building area. These footstep vibrations can be distinguished from other vibrations, and, once identified, the footsteps can be located. These locations, in turn, form the starting point of estimating occupancy in an area. In order to provide a meaningful occupancy count, however, it is first necessary to associate discrete footsteps with individuals. The proposed framework incorporates a tractable algorithm for this association task. The proposed algorithms operate online, updating occupancy count over time as new footsteps are detected. Experiments with measurements from a public building illustrate the operation of the proposed framework. This approach offers an advantage over others based on conventional technologies by avoiding the cost of a separate sensor system devoted to occupancy tracking.

  3. Non Linear Step By Step Seismic Response and the Push Over Analysis Comparison of a Reinforced Concrete of Ductile Frames 25 Level Building

    International Nuclear Information System (INIS)

    Avila, Jorge A.; Martinez, Eduardo

    2008-01-01

    Based on a ductile frames 25 level building, a non-linear analysis with increased monotonically lateral loads (Push-Over) was made in order to determine its collapse and its principal responses were compared against the time-history seismic responses determined with the SCT-EW-85 record. The seismic-resistance design and faced to gravitational loads was made according to the Complementary Technical Norms of Concrete Structures Design (NTC-Concrete) and the NTC-Seismic of the Mexico City Code (RDF-04), satisfying the limit service states (relative lateral displacement between story height maximum relations, story drifts ≤0.012) and failure (seismic behavior factor, Q = 3). The compressible (soft) seismic zone III b and the office use type (group B) were considered. The non-lineal responses were determined with nominal and over-resistance effects. The comparison were made with base shear force-roof lateral displacement relations, global distribution of plastic hinges, failure mechanics tendency, lateral displacements and story drift and its distribution along the height of the building, local and global ductility demands, etc. For the non-linear static analysis with increased monotonically lateral loads, was important to select the type of lateral forces distribution

  4. Vibration control of buildings by using partial floor loads as multiple tuned mass

    Directory of Open Access Journals (Sweden)

    Tharwat A. Sakr

    2017-08-01

    Full Text Available Tuned mass dampers (TMDs are considered as the most common control devices used for protecting high-rise buildings from vibrations. Because of their simplicity and efficiency, they have found wide practical applications in high-rise buildings around the world. This paper proposes an innovative technique for using partial floor loads as multiple TMDs at limited number of floors. This technique eliminates complications resulting from the addition of huge masses required for response control and maintains the mass of the original structure without any added loads. The effects of using partial loads of limited floors starting from the top as TMDs on the vibration response of buildings to wind and earthquakes are investigated. The effects of applying the proposed technique to buildings with different heights and characteristics are also investigated. A parametric study is carried out to illustrate how the behavior of a building is affected by the number of stories and the portion of the floor utilized as TMDs. Results indicate the effectiveness of the proposed control technique in enhancing the drift, acceleration, and force response of buildings to wind and earthquakes. The response of buildings to wind and earthquakes was observed to be more enhanced by increasing the story-mass ratios and the number of floor utilized as TMDs.

  5. Building structures

    CERN Document Server

    Ambrose, James

    2011-01-01

    James Ambrose is Editor of the Parker/Ambrose Series of Simplified Design Guides. He practiced as an architect in California and Illinois and as a structural engineer in Illinois. He was a professor of architecture at the University of Southern California. Patrick Tripeny is an Associate Professor, former director of the School of Architecture, and the current Director of the Center for Teaching and Learning Excellence at the University of Utah. He is a licensed architect in California. He has been the recipient of a number of teaching awards at the local and national level for his work in teaching structures and design. With James Ambrose, he is the coauthor of Simplified Engineering for Architects and Builders, Eleventh Edition; Simplified Design of Steel Structures, Eighth Edition; Simplified Design of Concrete Structures, Eighth Edition; and Simplified Design of Wood Structures, Sixth Edition, all published by Wiley.

  6. Using a Dialogue Journal to Build Responsibility and Self-Reliance: A Case Study

    Science.gov (United States)

    Krebs, Cathryn

    2006-01-01

    Using a dialogue journal during a school year helped a 10th-grade student focus on skills that build responsibility and self-reliance. The Expanded Core Curriculum (Hatlen, 1996) addresses disability specific skills that include compensatory and social interaction skills. Providing instruction in organization, time management, and self-advocacy…

  7. Effects of opening in shear walls of 30- storey building

    Directory of Open Access Journals (Sweden)

    Ruchi Sharma

    2015-03-01

    Full Text Available Tall towers and multi-storey buildings have fascinated mankind from the beginning of civilization, their construction being initially for defense and subsequently for ecclesiastical purposes. These tall buildings because of its height, is affected by lateral forces due to wind or earthquake actions tends to snap the building in shear and push it over in bending. In general, the rigidity (i.e. Resistance to lateral deflection and stability (i.e. Resistance to overturning moments requirement become more important. Shear walls (Structural walls contribute significant lateral stiffness, strength, and overall ductility and energy dissipation capacity. In many structural walls a regular pattern of openings has to be provided due to various functional requirements such as to accommodate doors, windows and service ducts. Such type of openings reduces the stiffness of the shear wall to some extent depending on the shape and size of the opening. In the present parametric study, efforts are made to investigate and critically assess the effects of various size of openings in shear walls on the responses and behaviors of multi-storey buildings. The 30 storey Prototype buildings with different types of openings in shear wall with and without incorporating the volume of shear wall reduced in the boundary elements are analyzed using software E-TABS using Response spectrum method (1893(Part-1-2002 and Time history method.

  8. Evaluation of modal pushover-based scaling of one component of ground motion: Tall buildings

    Science.gov (United States)

    Kalkan, Erol; Chopra, Anil K.

    2012-01-01

    Nonlinear response history analysis (RHA) is now increasingly used for performance-based seismic design of tall buildings. Required for nonlinear RHAs is a set of ground motions selected and scaled appropriately so that analysis results would be accurate (unbiased) and efficient (having relatively small dispersion). This paper evaluates accuracy and efficiency of recently developed modal pushover–based scaling (MPS) method to scale ground motions for tall buildings. The procedure presented explicitly considers structural strength and is based on the standard intensity measure (IM) of spectral acceleration in a form convenient for evaluating existing structures or proposed designs for new structures. Based on results presented for two actual buildings (19 and 52 stories, respectively), it is demonstrated that the MPS procedure provided a highly accurate estimate of the engineering demand parameters (EDPs), accompanied by significantly reduced record-to-record variability of the responses. In addition, the MPS procedure is shown to be superior to the scaling procedure specified in the ASCE/SEI 7-05 document.

  9. Analysis of a school building damaged by the 2015 Ranau earthquake Malaysia

    Science.gov (United States)

    Takano, Shugo; Saito, Taiki

    2017-10-01

    On June 5th, 2015 a severe earthquake with a moment Magnitude of 6.0 occurred in Ranau, Malaysia. Depth of the epicenter is 10 km. Due to the earthquake, many facilities were damaged and 18 people were killed due to rockfalls [1]. Because the British Standard (BS) is adopted as a regulation for built buildings in Malaysia, the seismic force is not considered in the structural design. Therefore, the seismic resistance of Malaysian buildings is unclear. To secure the human life and building safety, it is important to grasp seismic resistance of the building. The objective of this study is to evaluate the seismic resistance of the existing buildings in Malaysia built by the British Standard. A school building that was damaged at the Ranau earthquake is selected as the target building. The building is a four story building and the ground floor is designed to be a parking space for the staff. The structural types are infill masonries where main frame is configured by reinforced concrete columns and beams and brick is installed inside the frame as walls. Analysis is performed using the STERA_3D software that is the software to analyze the seismic performance of buildings developed by one of the authors. Firstly, the natural period of the building is calculated and compared with the result of micro-tremor measurement. Secondly, the nonlinear push-over analysis was conducted to evaluate the horizontal load bearing capacity of the building. Thirdly, the earthquake response analysis was conducted using the time history acceleration data measured at the Ranau earthquake by the seismograph installed at Kota Kinabalu. By comparing the results of earthquake response analysis and the actual damage of the building, the reason that caused damage to the building is clarified.

  10. Business Management in Sustainable Buildings: Ankara-Turkey Case

    Science.gov (United States)

    Kutay Karaca, Neşet; Burcu Gültekin, Arzuhan

    2017-10-01

    The concept of the sustainability is described as efficiently and effectively consuming of exhaustible and recyclable sources of the world. A sustainable building implements sustainability criteria in its life cycle, and business management is the process by which an organization uses its resources in the most efficient way to reach its goal. From the beginning, sustainable building proves their differences from the conventional buildings. Sustainable buildings are resource-efficient and environmentally responsible structures in terms of energy consumption, construction principles, siting, renovation and maintenance throughout its life cycle while conventional buildings are more traditional in these matters. The differences are observable especially in costs and expenditures. It is possible and feasible to compare and contrast the design, construction and management costs of both types of structures. Thence, contributions of sustainable buildings are priced favourably in terms of ecological and sociological aspects. In this context, a prospective projection can be made considering the extra costs of sustainable structures, as well as the consumption profits due to the use of less energy than conventional construction. Considering this, it is possible to project consumption savings in long term. By calculating a forward-looking net cash flow projection, it can be forecasted how much time it will take to cover the extra cost. When making decisions, investors always contemplate maximum profitability. Within the scope of this study, costs of sustainable and conventional buildings will be compared and contrasted through precedence of a sustainable building certificated and non-certificated building. It will be analysed in which time period the initial cost difference between them will be compensated totally and partially. Furthermore, an efficiency analyses will be done in the scope of the necessities and expenses of these businesses.

  11. Relevance feature selection of modal frequency-ambient condition pattern recognition in structural health assessment for reinforced concrete buildings

    Directory of Open Access Journals (Sweden)

    He-Qing Mu

    2016-08-01

    Full Text Available Modal frequency is an important indicator for structural health assessment. Previous studies have shown that this indicator is substantially affected by the fluctuation of ambient conditions, such as temperature and humidity. Therefore, recognizing the pattern between modal frequency and ambient conditions is necessary for reliable long-term structural health assessment. In this article, a novel machine-learning algorithm is proposed to automatically select relevance features in modal frequency-ambient condition pattern recognition based on structural dynamic response and ambient condition measurement. In contrast to the traditional feature selection approaches by examining a large number of combinations of extracted features, the proposed algorithm conducts continuous relevance feature selection by introducing a sophisticated hyperparameterization on the weight parameter vector controlling the relevancy of different features in the prediction model. The proposed algorithm is then utilized for structural health assessment for a reinforced concrete building based on 1-year daily measurements. It turns out that the optimal model class including the relevance features for each vibrational mode is capable to capture the pattern between the corresponding modal frequency and the ambient conditions.

  12. Experimental evaluation of BZ-GW (BACnet-ZigBee smart grid gateway) for demand response in buildings

    International Nuclear Information System (INIS)

    Hong, Seung Ho; Kim, Se Hwan; Kim, Gi Myung; Kim, Hyung Lae

    2014-01-01

    The SG (smart grid) is a modernized and a future-oriented electric grid that deals with the whole energy chain, from generation to consumer. Among the SG applications, DR (demand response) is an important control mechanism to manage the electricity consumption of the customer in response to supply conditions. In buildings, DR is managed through installed communication networks which support DR applications. BACnet is an international standard communication protocol for building automation and control systems. BACnet uses ZigBee as a wireless communication protocol. Both BACnet and ZigBee have their own DR applications. In this study, we developed a BACnet-ZigBee gateway that maps the DR application of BACnet to that of ZigBee and vice versa. In addition, we developed an experimental facility to demonstrate how the BACnet-ZigBee gateway can be implemented for DR applications in buildings. We also measured the communication delay to verify that the BZ-GW (BACnet-ZigBee smart grid gateway) developed here satisfies the requirements of real-time DR service in buildings. - Highlights: • Developed a gateway that maps the DR application of BACnet to that of ZigBee. • Verified satisfaction for real-time requirement using experimental facility. • The gateway and other device will play a infrastructure role in buildings. • The implementation method could become a reference model for future similar

  13. Seismic resistance design of nuclear power plant building structures in Japan

    International Nuclear Information System (INIS)

    Kitano, Takehito

    1997-01-01

    Japan is one of the countries where earthquakes occur most frequently in the world and has incurred a lot of disasters in the past. Therefore, the seismic resistance design of a nuclear power plant plays a very important role in Japan. This report describes the general method of seismic resistance design of a nuclear power plant giving examples of PWR and BWR type reactor buildings in Japan. Nuclear facilities are classified into three seismic classes and is designed according to the corresponding seismic class in Japan. Concerning reactor buildings, the short-term allowable stress design is applied for the S1 seismic load and it is confirmed that the structures have a safety margin against the S2 seismic load. (J.P.N.)

  14. Seismic resistance design of nuclear power plant building structures in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Kitano, Takehito [Kansai Electric Power Co., Inc., Osaka (Japan)

    1997-03-01

    Japan is one of the countries where earthquakes occur most frequently in the world and has incurred a lot of disasters in the past. Therefore, the seismic resistance design of a nuclear power plant plays a very important role in Japan. This report describes the general method of seismic resistance design of a nuclear power plant giving examples of PWR and BWR type reactor buildings in Japan. Nuclear facilities are classified into three seismic classes and is designed according to the corresponding seismic class in Japan. Concerning reactor buildings, the short-term allowable stress design is applied for the S1 seismic load and it is confirmed that the structures have a safety margin against the S2 seismic load. (J.P.N.)

  15. High-rise buildings under multi-hazard environment assessment and design for optimal performance

    CERN Document Server

    Huang, Mingfeng

    2017-01-01

    This book discusses performance-based seismic and wind-resistant design for high-rise building structures, with a particular focus on establishing an integrated approach for performance-based wind engineering, which is currently less advanced than seismic engineering. This book also provides a state-of-the-art review of numerous methodologies, including computational fluid dynamics (CFD), extreme value analysis, structural optimization, vibration control, pushover analysis, response spectrum analysis, modal parameter identification for the assessment of the wind-resistant and seismic performance of tall buildings in the design stage and actual tall buildings in use. Several new structural optimization methods, including the augmented optimality criteria method, have been developed and employed in the context of performance-based design. This book is a valuable resource for students, researchers and engineers in the field of civil and structural engineering.

  16. Structure of steel reactor building and construction method therefor

    International Nuclear Information System (INIS)

    Yamakawa, Toshikimi.

    1997-01-01

    The building of the present invention contains a reactor pressure vessel, and has double steel plate walls endurable to elevation of inner pressure and keeping airtightness, and shielding concretes are filled between the double steel plate walls. It also has empty double steel plate walls not filled with concretes and has pipelines, vent ducts, wirings and a support structures for attaching them between the double steel plate walls. It is endurable to a great inner pressure satisfactory and keeps airtightness by the two spaced steel plates. It can be greatly reduced in the weight, and can be manufactured efficiently with high quality in a plant by so called module construction, and the dimension of the entire of the reactor building can be reduced. It is constructed in a dock, transported on the sea while having the space between the two steel plate walls as a ballast tanks, placed in the site, and shielding concretes are filled between the double steel plate walls. The term for the construction can be reduced, and the cost for the construction can be saved. (N.H.)

  17. Use of EMW radiation in the building industry at defects in buildings

    Directory of Open Access Journals (Sweden)

    Sobotka Jindřich

    2017-01-01

    Full Text Available This paper discusses theory and application of microwave radiation and experimental optimization of microwave radiation to eliminate moisture content in wood elements. It will be appreciated that the rising moisture leaking into the structure, resulting in defects and structures of the buildings themselves. Owing to its properties, microwave radiation has been used in the construction industry in modern times, in particular to dry wet masonry of buildings. Effects of electromagnetic radiation on building structures lead to relatively sharp decreases in moisture content from damp building structures or elements. The influence of electromagnetic radiation on building structures lead to oscillation of water molecules contained in the material, which cause a phase transformation of water into vapour. Consequently, the vapour evaporates from the moist material, thereby drying the element exposed to radiation. The article describes experiments carried out at the Faculty of Civil Engineering of the Faculty of Technology in Brno that demonstrate successful decrease of water content in building materials using microwave radiation. First, the understanding of microwave radiation will be discussed. Following an analysis of research results an optimum intensity of microwave radiation sources as well as the necessary length of the irradiation of microwave radiation have been determined with respect to the particular type of building material and the success rate of elimination of moisture.

  18. Earthquake response of inelastic structures

    International Nuclear Information System (INIS)

    Parulekar, Y.M.; Vaity, K.N.; Reddy, .R.; Vaze, K.K.; Kushwaha, H.S.

    2004-01-01

    The most commonly used method in the seismic analysis of structures is the response spectrum method. For seismic re-evaluation of existing facilities elastic response spectrum method cannot be used directly as large deformation above yield may be observed under Safe Shutdown Earthquake (SSE). The plastic deformation, i.e. hysteretic characteristics of various elements of the structure cause dissipation of energy. Hence the values of damping given by the code, which does not account hysteretic energy dissipation cannot be directly used. In this paper, appropriate damping values are evaluated for 5-storey, 10-storey and 15-storey shear beam structures, which deform beyond their yield limit. Linear elastic analysis is performed for the same structures using these damping values and the storey forces are compared with those obtained using inelastic time history analysis. A damping model, which relates ductility of the structure and damping, is developed. Using his damping model, a practical structure is analysed and results are compared with inelastic time history analysis and the comparison is found to be good

  19. Development of safety enhancement technology of containment building

    International Nuclear Information System (INIS)

    Seo, Jeong Moon; Choun, Y. S.; Choi, I. K.

    2002-04-01

    This study consists of four research areas, (1) Seismic safety assessment, (2) Aging assessment of a containment building, (3) Prediction of long-term behavior and analysis of a containment building, (4) Performance verification of a containment building. In the seismic safety assessment area, responses of a containment building were monitored and the analysis method was verified. Also performed are the identification of earthquake characteristics and improvement of the seismic fragility analysis method. In the area of aging assessment of a containment building, we developed aging management code SLMS and database. Aging tests were performed for containment building materials and aging models were developed. Techniques for investigation, detection, and evaluation of aging were developed. In the area of prediction of long-term behavior and analysis of a containment building, we developed a non-linear structural analysis code NUCAS and material models. In the area of performance verification of a containment building, we analyzed the crack behavior of a containment wall and the behavior of the containment under internal pressure. We also improved the ISI methods for prestressed containment

  20. Accuracy Assessment in Determining the Location of Corners of Building Structures Using a Combination of Various Measurement Methods

    Science.gov (United States)

    Krzyżek, Robert; Przewięźlikowska, Anna

    2017-12-01

    When surveys of corners of building structures are carried out, surveyors frequently use a compilation of two surveying methods. The first one involves the determination of several corners with reference to a geodetic control using classical methods of surveying field details. The second method relates to the remaining corner points of a structure, which are determined in sequence from distance-distance intersection, using control linear values of the wall faces of the building, the so-called tie distances. This paper assesses the accuracy of coordinates of corner points of a building structure, determined using the method of distance-distance intersection, based on the corners which had previously been determined by the conducted surveys tied to a geodetic control. It should be noted, however, that such a method of surveying the corners of building structures from linear measures is based on the details of the first-order accuracy, while the regulations explicitly allow such measurement only for the details of the second- and third-order accuracy. Therefore, a question arises whether this legal provision is unfounded, or whether surveyors are acting not only against the applicable standards but also without due diligence while performing surveys? This study provides answers to the formulated problem. The main purpose of the study was to verify whether the actual method which is used in practice for surveying building structures allows to obtain the required accuracy of coordinates of the points being determined, or whether it should be strictly forbidden. The results of the conducted studies clearly demonstrate that the problem is definitely more complex. Eventually, however, it might be assumed that assessment of the accuracy in determining a location of corners of a building using a combination of two different surveying methods will meet the requirements of the regulation [MIA, 2011), subject to compliance with relevant baseline criteria, which have been

  1. Main building complex WWER 440/213 upper range design response spectra for soft soil site conditions (Paks)

    International Nuclear Information System (INIS)

    Krutzik, N.

    1996-01-01

    Within the Benchmark studies parallel investigation were prepared for the main building complex of the WWER-440/213 Paks NPP by several participating institutions. The investigations were based on various mathematical models and procedures but all had the same seismological data as input. The calculation methods as well as software tools were different. This report covers the enveloped response results which were the basis for the benchmark studies and which should be used for upgrading of mechanical and electrical components and systems which will follow. These response spectra which consider a certain conservatism namely neglecting the frequency independence of the stiffness and the cut-off of damping values are named 'Upper Range design Benchmark Response Spectra' for the main building of Paks NPP

  2. Main building complex WWER 440/213 upper range design response spectra for soft soil site conditions (Paks)

    Energy Technology Data Exchange (ETDEWEB)

    Krutzik, N [Siemens AG, Power Generation Group (KWU) NDA2, Offenbach (Germany)

    1996-07-01

    Within the Benchmark studies parallel investigation were prepared for the main building complex of the WWER-440/213 Paks NPP by several participating institutions. The investigations were based on various mathematical models and procedures but all had the same seismological data as input. The calculation methods as well as software tools were different. This report covers the enveloped response results which were the basis for the benchmark studies and which should be used for upgrading of mechanical and electrical components and systems which will follow. These response spectra which consider a certain conservatism namely neglecting the frequency independence of the stiffness and the cut-off of damping values are named 'Upper Range design Benchmark Response Spectra' for the main building of Paks NPP.

  3. The assessment of fire safety of cast iron structures in historical buildings: Theory and practice

    NARCIS (Netherlands)

    Twilt, L.; Hunen, M. van

    2000-01-01

    The assessment of structural fire safety of cast iron structures in historical buildings is difficult because the available information on the fire behaviour is limited, whilst the fire design assumptions (if any) often are not well docu-mented. A complicating factor with regard to protective

  4. Economic Feasibility Analysis of the Application of Geothermal Energy Facilities to Public Building Structures

    Directory of Open Access Journals (Sweden)

    Sangyong Kim

    2014-03-01

    Full Text Available This study aims to present an efficient plan for the application of a geothermal energy facility at the building structure planning phase. Energy consumption, energy cost and the primary energy consumption of buildings were calculated to enable a comparison of buildings prior to the application of a geothermal energy facility. The capacity for energy savings and the costs related to the installation of such a facility were estimated. To obtain more reliable criteria for economic feasibility, the lifecycle cost (LCC analysis incorporated maintenance costs (reflecting repair and replacement cycles based on construction work specifications of a new renewable energy facility and initial construction costs (calculated based on design drawings for its practical installation. It is expected that the findings of this study will help in the selection of an economically viable geothermal energy facility at the building construction planning phase.

  5. Assisting the development of innovative responsive façade elements using building performance simulation

    NARCIS (Netherlands)

    de Klijn-Chevalerias, M.L.; Loonen, R.C.G.M.; Zarzycka, A.; de Witte, D.; Sarakinioti, M.V.; Hensen, JLM; Turrin, Michela; Peters, Brady; O'Brien, William; Stouffs, Rudi; Dogan, Timur

    2017-01-01

    Thermal mass is usually positively associated with energy efficiency and thermal comfort in buildings. However, the slow response of heavyweight constructions is not beneficial at all times, as these dynamic effects may actually also increase heating and cooling energy demand during intermittent

  6. Pseudodynamic tests on a full-scale 3-storey precast concrete building: Global response

    OpenAIRE

    Negro, Paolo; Bournas, Dionysios A.; Molina, Francisco J.

    2013-01-01

    In the framework of the SAFECAST Project, a full-scale three-storey precast building was subjected to a series of pseudodynamic (PsD) tests in the European Laboratory for Structural Assessment (ELSA). The mock-up was constructed in such a way that four different structural configurations could be investigated experimentally. Therefore, the behaviour of various parameters like the types of mechanical connections (traditional as well as innovative) and the presence or absence of shear walls alo...

  7. Responses of two tall buildings in Tokyo, Japan, before, during, and after the M9.0 Tohoku earthquake of 11 March 2011

    Science.gov (United States)

    Çelebi, Mehmet; Hisada, Yoshiuaki; Omrani, Roshanak; Ghahari, S. Farid; Taciroglu, Ertugrul

    2016-01-01

    The 11 March 2011 M 9.0 Tohoku earthquake generated significant long duration shaking that propagated hundreds of kilometers from the epicenter and affected urban areas throughout much of Honshu. Recorded responses of tall buildings at several hundred km from the epicenter of the main shock and other events show tall buildings were affected by long-period motions of events at distant sources. This study presents behavioral aspects of 29-story and 30-story neighboring buildings in the Shinjuku area of Tokyo, Japan, as inferred from records retrieved from a sparse array of accelerometers deployed in the superstructures, at ground and 100 m below the ground level over a time interval covering before, during, and after the main shock. Such long-period effects are common in several regions of Japan as well as in the United States and in other seismically active countries. Permanent shifts in fundamental frequencies are observed. Drift ratios indicate possible structural nonlinear behavior occurred during the main shock. The need to consider risks to built environments from distant sources, including those in neighboring countries, is emphasized.

  8. On the effectiveness of smart technologies in the seismic protection of existing buildings Part I: Masonry structures

    International Nuclear Information System (INIS)

    Mandara, A.; Ramundo, F.; Spina, G.

    2008-01-01

    The first part of a study concerning innovative intervention techniques for dissipate a share of the input seismic energy compatible with the preservation of existing buildings, including historical and monumental constructions, is presented in this paper. The case of a typical scheme of a long-bay box-like masonry building fitted with a dissipative floating roof is analyzed. In the examined building a wide simulation analysis has shown the achievement of a very satisfying performance. Furthermore, the effectiveness of the system can be maximized by means of active or semi-active devices implemented in the floating roof and a significant reduction of the seismic impact on the building can be obtained compared with non-controlled or simply passively controlled structure. The results prove the remarkable increase of the energy dissipation capability of the system, as well as the reduction of structural damage, independently of any specific strengthening intervention

  9. Rigidly framed earth retaining structures thermal soil structure interaction of buildings supporting unbalanced lateral earth pressures

    CERN Document Server

    Aboumoussa, Walid

    2014-01-01

    Structures placed on hillsides often present a number of challenges and a limited number of economical choices for site design. An option sometimes employed is to use the building frame as a retaining element, comprising a Rigidly Framed Earth Retaining Structure (RFERS). The relationship between temperature and earth pressure acting on RFERS, is explored in this monograph through a 4.5 year monitoring program of a heavily instrumented in service structure. The data indicated that the coefficient of earth pressure behind the monitored RFERS had a strong linear correlation with temperature. The study also revealed that thermal cycles, rather than lateral earth pressure, were the cause of failure in many structural elements. The book demonstrates that depending on the relative stiffness of the retained soil mass and that of the structural frame, the developed lateral earth pressure, during thermal expansion, can reach magnitudes several times larger than those determined using classical earth pressure theories....

  10. Design Process for Integrated Concepts with Responsive Building Elements

    DEFF Research Database (Denmark)

    Aa, Van der A.; Heiselberg, Per

    2008-01-01

    An integrated building concept is a prerequisite to come to an energy efficient building with a good and healthy IAQ indoor comfort. A design process that defines the targets and boundary conditions in the very first stage of the design and guarantees them until the building is finished and used...... is needed. The hard question is however: how to make the right choice of the combination of individual measures from building components and building services elements. Within the framework of IEA-ECBCS Annex 44 research has been conducted about the design process for integrated building concepts...

  11. Dynamic Model of a Structure Carrying Stationary Humans and Assessment of its Response to Walking Excitation

    DEFF Research Database (Denmark)

    Pedersen, Lars

    2007-01-01

    A flooring-system, e.g. a floor in a building, is excited dynamically when a person walks across the floor, and resonant excitation might bring structural vibrations to unacceptable levels. Stationary (non-moving) crowds of people might be present on the same floor and they will sense the floor...... vibrations, but they will also interact dynamically with the floor in a passive sense, thus altering the dynamic system excited to vibration by the walking person. Consequently, the vibration level of the floor is likely to depend on the presence and size of the stationary crowd. It is also known...... that different techniques (different parameters calculated from structural response time series) are proposed for assessing floor serviceability. The paper looks into the influence of the stationary crowd of people on the floor response to walking excitation and into the influence of the crowd on different...

  12. The development of an expert system for finding fragility curves of building structural systems in the preliminary design stage

    International Nuclear Information System (INIS)

    Yee, L.Y.; Okrent, D.

    1987-01-01

    This research is a starting point for the development of an expert system for determining seismic fragility curves of structural systems in a nuclear power plant or conventional building at the preliminary design stage. The resulting system assists an engineer with moderate engineering background and limited reliability knowledge to analyze the failure functions of building structures. It simulates the performance of an expert in identifying the potential failure modes and their variabilities for a structure of interest. On reviewing the methodology of seismic fragility evaluation for existing building structures in the nuclear power plant industry, one finds that the investigation process starts with the identification of critical components or substructures, whose failures result in the functional failure of safety related equipment or the failure of structural integrity itself, and follows with complicated numerical analyses to estimate the capacity functions associated with the limit states of these components or substructures

  13. Clearance of buildings for demolition: ways to clearance on the standing structure for covered surfaces and inaccessible areas

    International Nuclear Information System (INIS)

    Thraenert, S.; Riemann, T.

    2014-01-01

    In general terms, the TUV NORD Nuclear services encompass safety assessments, design reviews, documentation re-views and inspections. They reflect the full scope of a technical service provider in the nuclear field. In the domestic market, these services are provided for the regulator, whereas in the international market any party involved in a nuclear project is a potential customer of TUV NORD Nuclear. This implies that TUV NORD Nuclear is offering consultancy, engineering and inspection services. Regarding the clearance of buildings for demolition, there are two different possible ways for the radiological characterization. The first option is a characterization on the standing structure before demolition and the second option is the characterization of the building rubble after demolition. According to the German Radiation Protection Ordinance, buildings of decommissioned nuclear sites have to be preferentially cleared on the standing structure. If compliance with the surface specific clearance levels is achieved on the standing structure, usually the cleared buildings can be demolished and the resulting rubble may be used without any further radiological considerations. In the case of the former nuclear power plant Wuergassen the majority of the building rubble is scheduled to stay on site to serve as backfill for the building pit. As such a scenario was not considered in the radiological considerations of, e.g., the German Radiation Protection Ordinance, an additional dose calculation was carried out for Wuergassen NPP basing on its radiological characteristics to directly prove compliance with the de-minimis-concept. The radiation controlled area (RCA) of Wuergassen NPP comprises an area of about 140.000 m 2 . This area is more or less easily accessible to characterization and decontamination using, if necessary, scaffoldings or lifting platforms. Up to the beginning of 2013, compliance with the surface specific clearance levels was verified on the standing

  14. Implementation of the ANNs ensembles in macro-BIM cost estimates of buildings' floor structural frames

    Science.gov (United States)

    Juszczyk, Michał

    2018-04-01

    This paper reports some results of the studies on the use of artificial intelligence tools for the purposes of cost estimation based on building information models. A problem of the cost estimates based on the building information models on a macro level supported by the ensembles of artificial neural networks is concisely discussed. In the course of the research a regression model has been built for the purposes of cost estimation of buildings' floor structural frames, as higher level elements. Building information models are supposed to serve as a repository of data used for the purposes of cost estimation. The core of the model is the ensemble of neural networks. The developed model allows the prediction of cost estimates with satisfactory accuracy.

  15. Location-specific responses to thermal stress in larvae of the reef-building coral Montastraea faveolata.

    Directory of Open Access Journals (Sweden)

    Nicholas R Polato

    2010-06-01

    Full Text Available The potential to adapt to a changing climate depends in part upon the standing genetic variation present in wild populations. In corals, the dispersive larval phase is particularly vulnerable to the effects of environmental stress. Larval survival and response to stress during dispersal and settlement will play a key role in the persistence of coral populations.To test the hypothesis that larval transcription profiles reflect location-specific responses to thermal stress, symbiont-free gametes from three to four colonies of the scleractinian coral Montastraea faveolata were collected from Florida and Mexico, fertilized, and raised under mean and elevated (up 1 to 2 degrees C above summer mean temperatures. These locations have been shown to exchange larvae frequently enough to prevent significant differentiation of neutral loci. Differences among 1,310 unigenes were simultaneously characterized using custom cDNA microarrays, allowing investigation of gene expression patterns among larvae generated from wild populations under stress. Results show both conserved and location-specific variation in key processes including apoptosis, cell structuring, adhesion and development, energy and protein metabolism, and response to stress, in embryos of a reef-building coral.These results provide first insights into location-specific variation in gene expression in the face of gene flow, and support the hypothesis that coral host genomes may house adaptive potential needed to deal with changing environmental conditions.

  16. Ten questions concerning integrating smart buildings into the smart grid

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, Thomas M.; Boudreau, Marie-Claude; Helsen, Lieve; Henze, Gregor; Mohammadpour, Javad; Noonan, Doug; Patteeuw, Dieter; Pless, Shanti; Watson, Richard T.

    2016-11-01

    Recent advances in information and communications technology (ICT) have initiated development of a smart electrical grid and smart buildings. Buildings consume a large portion of the total electricity production worldwide, and to fully develop a smart grid they must be integrated with that grid. Buildings can now be 'prosumers' on the grid (both producers and consumers), and the continued growth of distributed renewable energy generation is raising new challenges in terms of grid stability over various time scales. Buildings can contribute to grid stability by managing their overall electrical demand in response to current conditions. Facility managers must balance demand response requests by grid operators with energy needed to maintain smooth building operations. For example, maintaining thermal comfort within an occupied building requires energy and, thus an optimized solution balancing energy use with indoor environmental quality (adequate thermal comfort, lighting, etc.) is needed. Successful integration of buildings and their systems with the grid also requires interoperable data exchange. However, the adoption and integration of newer control and communication technologies into buildings can be problematic with older legacy HVAC and building control systems. Public policy and economic structures have not kept up with the technical developments that have given rise to the budding smart grid, and further developments are needed in both technical and non-technical areas.

  17. SSI on the Dynamic Behaviour of a Historical Masonry Building: Experimental versus Numerical Results

    Directory of Open Access Journals (Sweden)

    Francesca Ceroni

    2014-11-01

    Full Text Available A reliable procedure to identify the dynamic behaviour of existing masonry buildings is described in the paper, referring to a representative case study: a historical masonry palace located in Benevento (Italy. Since the building has been equipped with a permanent dynamic monitoring system by the Department of Civil Protection, some of the recorded data, acquired in various operating conditions, have been analysed with basic instruments of the Operational Modal Analysis in order to identify the main eigenfrequencies and vibration modes of the structure. The obtained experimental results have been compared to the numerical outcomes provided by three detailed Finite Element (FE models of the building. The influence of Soil-Structure Interaction (SSI has been also introduced in the FE model by a sub-structure approach where concentrated springs were placed at the base of the building to simulate the effect of soil and foundation on the global dynamic behaviour of the structure. The obtained results evidence that subsoil cannot a priori be disregarded in identifying the dynamic response of the building.

  18. Structural response of rectilinear containment to overpressurization

    International Nuclear Information System (INIS)

    Pfeiffer, P.A.; Kulak, R.F.

    1995-01-01

    Containment structures for nuclear reactors are the final barrier between released radionuclides and the public. Containment structures are constructed from steel, reinforced concrete, or prestressed concrete. US nuclear reactor containment geometries tend to be cylindrical with elliptical or hemispherical heads. The older Soviet designed reactors do not use a containment building to mitigate the effects of accidents. Instead, they employ a sealed set of rectilinear, interconnected compartments, collectively called the accident localization system (ALS), to reduce the release of radionuclides to the atmosphere during accidents. The purpose of this paper is to present a methodology that can be used to find the structural capacity of reinforced concrete structures. The method is applicable to both cylindrical and rectilinear geometries. As an illustrative example, the methodology is applied to a generic VVER-440/V213 design

  19. Dynamic soil-structure interaction analysis based on discretized Green function

    International Nuclear Information System (INIS)

    Muto, K.; Kobayashi, T.; Nakahara, M.

    1983-01-01

    In the seismic design of massive and rigid structure such as a nuclear reactor building, it is important to evaluate the dynamic interaction effect between soil and structure. The authors developed an advanced and practical method to evaluate the interaction effect between the soil which is considered to be semi-infinite elastic medium, and the structure in which flexibility is considered. In this report, this method is applied to a seismic analysis of the full size BWR Mark I type reactor building. For horizontal input earthquake, the vibrational degrees of freedom shall be considered both horizontal and vertical as the rocking response occurs because of the overturning moment caused by the building's horizontal response. The results of earthquake response analysis show that the floors deform in-place and the response acceleration at the center of the floor is larger than that of at the side wall. The response spectra also differ each other even if on the same floor because of the in-place deformation of the floor slab. It means that in analytical modeling of the reactor building, multi-stick model considering deformation of floor slab is required instead of single-stick model. The ratio of the peak acceleration response of the roof floor to the input earthquake is about 2.5. (orig./HP)

  20. Experimental and analytical studies for a BWR nuclear reactor building. Evaluation of soil-structure interaction behaviour

    International Nuclear Information System (INIS)

    Mizuno, N.; Tsushima, Y.

    1975-01-01

    This paper evaluates the spatial characteristics of dynamic properties, especially soil-structure interaction behaviour, of the BWR nuclear building by experimental and analytical studies. It is well known that the damping effects in soil-structure interaction are remarkable on the building with short periods by the dissipation of vibrational energy to the soil. The authors have previously reported an analytical method for estimating the damping effects the properties of which are characterized as follows: 1) The complex damping is used, because the so-called structural damping may be more suitable for estimating the damping effects of an elastic structure. 2) H. Tajimi's theory is used for estimating the dynamical soil-foundation stiffness with the dissipation of vibrational energy on the elastic half-space soil. In this paper, an approximate explanation is presented in regard to the more developmental mathematical method for estimating the damping effects than the above-mentioned previous method, which is 'Modes Superposition Method for Multi-Degrees of Freedom System' with the constant complex stiffness showing the structural damping effects and the dynamical soil-foundation stiffness approximated by the linear or quadratic functions of the eigenvalues. An approximate explanation is presented in regard to the experimental results of the No. 1 reactor building (BWR) of Hamaoka Nuclear Power Station, The Chubu Electric Power Co., Ltd. (Auth.)

  1. Study on reactor building structure using ultrahigh strength materials, 1

    International Nuclear Information System (INIS)

    Ishimura, Kikuo; Odajima, Masahiro; Irino, Kazuo; Hashiba, Toshio.

    1991-01-01

    This study was promoted to be aimed at realization of the optimal nuclear reactor building structure of the future. As the first step, the study regarding ultrahigh strength reinforced concrete (abbr. RC) shear wall was selected. As the result of various tests, the application of ultrahigh strength RC shear walls was verified. The tests conducted were relevant to; ultrahigh strength concrete material tests; pure shear tests of RC flat panels; and bending shear tests and its simulation analysis of RC shear walls. (author)

  2. Comparison of Demand Response Performance with an EnergyPlus Model in a Low Energy Campus Building

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, Junqiao Han; Black, Doug; Apte, Mike; Piette, Mary Ann; Berkeley, Pam

    2010-05-14

    We have studied a low energy building on a campus of the University of California. It has efficient heating, ventilation, and air conditioning (HVAC) systems, consisting of a dual-fan/dual-duct variable air volume (VAV) system. As a major building on the campus, it was included in two demand response (DR) events in the summers of 2008 and 2009. With chilled water supplied by thermal energy storage in the central plant, cooling fans played a critical role during DR events. In this paper, an EnergyPlus model of the building was developed and calibrated. We compared both whole-building and HVAC fan energy consumption with model predictions to understand why demand savings in 2009 were much lower than in 2008. We also used model simulations of the study building to assess pre-cooling, a strategy that has been shown to improve demand saving and thermal comfort in many types of building. This study indicates a properly calibrated EnergyPlus model can reasonably predict demand savings from DR events and can be useful for designing or optimizing DR strategies.

  3. Updating of a dynamic finite element model from the Hualien scale model reactor building

    International Nuclear Information System (INIS)

    Billet, L.; Moine, P.; Lebailly, P.

    1996-08-01

    The forces occurring at the soil-structure interface of a building have generally a large influence on the way the building reacts to an earthquake. One can be tempted to characterise these forces more accurately bu updating a model from the structure. However, this procedure requires an updating method suitable for dissipative models, since significant damping can be observed at the soil-structure interface of buildings. Such a method is presented here. It is based on the minimization of a mechanical energy built from the difference between Eigen data calculated bu the model and Eigen data issued from experimental tests on the real structure. An experimental validation of this method is then proposed on a model from the HUALIEN scale-model reactor building. This scale-model, built on the HUALIEN site of TAIWAN, is devoted to the study of soil-structure interaction. The updating concerned the soil impedances, modelled by a layer of springs and viscous dampers attached to the building foundation. A good agreement was found between the Eigen modes and dynamic responses calculated bu the updated model and the corresponding experimental data. (authors). 12 refs., 3 figs., 4 tabs

  4. Structural optimization for nonlinear dynamic response

    DEFF Research Database (Denmark)

    Dou, Suguang; Strachan, B. Scott; Shaw, Steven W.

    2015-01-01

    by a single vibrating mode, or by a pair of internally resonant modes. The approach combines techniques from nonlinear dynamics, computational mechanics and optimization, and it allows one to relate the geometric and material properties of structural elements to terms in the normal form for a given resonance......Much is known about the nonlinear resonant response of mechanical systems, but methods for the systematic design of structures that optimize aspects of these responses have received little attention. Progress in this area is particularly important in the area of micro-systems, where nonlinear...... resonant behaviour is being used for a variety of applications in sensing and signal conditioning. In this work, we describe a computational method that provides a systematic means for manipulating and optimizing features of nonlinear resonant responses of mechanical structures that are described...

  5. PRE-CAST WALL PRODUCTS MADE FROM LIGHTWEIGHT CONCRETE FOR ENCLOSING STRUCTURES OF BUILDINGS

    Directory of Open Access Journals (Sweden)

    M. R. Hadgiev

    2014-01-01

    Full Text Available The paper is devoted to the actual problem waste dismantling of buildings and structures in the form of brick waste with reception the secondary fine and coarse aggregate and concrete based on them for the manufacture of small-piece wall products. 

  6. Comparison of the dynamic response of the structures of a typical DWR-reactor-building to the load cases earthquake, aircraft impact and explosion

    International Nuclear Information System (INIS)

    Schrader, K.-H.; Kaiser, A.; Krutzik, N.

    1978-01-01

    For the design of equipment and components of nuclear power plants with respect to their dynamic behavior it is necessary to know the dynamic load due to shock, or vibrating excitations, which might arise during the life time of the plant. In Germany these load cases are those listed in the heading. The objective of the paper is to compare the characteristics of the responses of the structure, which then have to serve as dynamic loads for the equipment. The paper deals with the following subjects:-survey and introduction of the code in Germany -conclusions concerning the mathematical model and the mechanical system for the computation of the dynamic response-comparison of the results which includes eigensystems, an overall picture of max/min values for displacements, as well as times histories and response spectra for critical points of the structure. For the F.E. Model, composed structures of ring elements and the method of the modal analysis have been used. (Author)

  7. Transmission of low-magnitude seismic excitation into Hanford Site structures

    International Nuclear Information System (INIS)

    Weiner, E.O.

    1989-01-01

    Several Hanford Site buildings were analyzed using simplified models to gain insight as to what extent the free field motion of a small-magnitude earthquake is transmitted into building structures as a result of soil-structure interaction effects. Building selection included the Plutonium Processing Plant, B-Plant and the Fast Flux Test Facility containment which represented a variety of stiffnesses, weights, and embedments. An artificial time history for the free field has a peak response at 13 Hz. This motion represents a median for magnitude 4 and 4.5 earthquakes, respectively. Floor response spectra were compared with results from analyses to design basis ground motions using the same structural models. Considerable attenuation of the small-magnitude free-field motion was found in the case of stiff, deeply embedded structures. This attenuation is attributed to kinematic interaction in addition to attenuation with depth in the free field. Even with such attenuation, there are exceptions where small magnitude responses exceed design basis responses. They are generally associated with 10 to 20 Hz modes with vertical motion

  8. Bore pile foundation tall buildings closed in the heritage building

    Science.gov (United States)

    Triastuti, Nusa Setiani

    2017-11-01

    Bore pile foundation for high building surroundings heritage building should be not damage. Construction proses must good, no necking, no mixed deep water, no sliding soil, nonporous concrete. Objective the execution of bore pile so that heritage buildings and neighboring buildings that are old do not experience cracks, damage and tilting. The survey methodology was observe the process of the implementation of the dominant silt, clay soil, in addition a limited space and to analyze the results of loading tests, investigations of soil and daily reports. Construction process determines the success of the structure bore pile in high building structure bearing, without damaging a heritage building. Attainment the hard soil depth, density concrete, observable clean reinforcement in the implementation. Monitoring the implementation of, among others, the face of the ground water little reduce in the area and outside the footprint of the building, no impact of vibration drilling equipment, watching the mud content on the water coming out at the time of drilling, concrete volume was monitored each 2 m bore depth of pile, The result researched heritage building was not damage. The test results bore pile axial, lateral analyzed the results have the appropriate force design required.

  9. Seismic dynamic analysis of Heat Exchangers inside of the Auxiliary Buildings in AP1000TM NPP

    International Nuclear Information System (INIS)

    Di Fonzo, M.; Aragon, J.; Moraleda, F.; Palazuelos, M.; San Vicente, J. L.

    2011-01-01

    Seismic dynamic analysis was carried out for the Heat Exchangers (RNS-HR) located inside of the Auxiliary Building in AP 1000 T M NPP. The main function of the RNS-HX is to provide shutdown reactor cooling. These equipment's are safety-related. So the seismic analysis was done using the methodology for Seismic Category I (SCI) structures. The most important topic is that the RNS-HX shall withstand the effects of the Safe Shutdown Earthquake (SSE) and maintain the specified design functions. for the analysis, two finite element models (FEM) were built in order to investigate the structural response of the couple system of building and equipment. The response spectra method was used. The floor response spectra (FRS) at the slab-wall connection were used as input Lateral seismic restrain was necessary to added in order to achieve the natural frequency of 33 Hz. The global structural response was obtained by means of the modal combination method indicated in the Regulatory Guide 1.92.

  10. Japanese contributions to containment structure, assembly and maintenance and reactor building for ITER

    International Nuclear Information System (INIS)

    Shibanuma, Kiyoshi; Honda, Tsutomu; Kanamori, Naokazu

    1991-06-01

    Joint design work on Conceptual Design Activity of International Thermonuclear Experimental Reactor (ITER) with four parties, Japan, the United States, the Soviet Union and the European Community began in April 1988 and was successfully completed in December 1990. In Japan, the home team was established in wide range of collaboration between JAERI and national institute, universities and heavy industries. The Fusion Experimental Reactor (FER) Team at JAERI is assigned as a core of the Japanese home team to support the joint Team activity and mainly conducted the design and R and D in the area of containment structure, remote handling and plant system. This report mainly describes the Japanese contribution on the ITER containment structure, remote handling and reactor building design. Main areas of contributions are vacuum vessel, attaching locks, electromagnetic analysis, cryostat, port and service line layout for containment structure, in-vessel handling equipment design and analysis, blanket handling equipment design and related short term R and D for assembly and maintenance, and finally reactor building design and analysis based on the equipment and service line layout and components flow during assembly and maintenance. (author)

  11. Building materials. Stichwort Baustoff

    Energy Technology Data Exchange (ETDEWEB)

    Rohwer, W

    1981-01-01

    To handle building materials properly, one must know about their characteristics. This pocket book will be of help: structured like a glossary, it gives brief descriptions of the most common building materials. It is small and handy enough to be a constant companion to resident engineers, foremen, gangers, building tradesmen, and construction workers and an aid in their training. The following groups of building materials are discussed: Natural stone; units for brick walls, floors, and roofs; mortar and concrete (definitions, binders, aggregates, additives, admixtures, mixing water); special types of plaster and rendering; light-weight building boards and wood wool basis; multilayer light-weight building boards; gypsum plasterboards; chimney construction; sewers; thermal insulation and sound section; structural steels; plastics.

  12. Lateral-torsional response of base-isolated buildings with curved surface sliding system subjected to near-fault earthquakes

    Science.gov (United States)

    Mazza, Fabio

    2017-08-01

    The curved surface sliding (CSS) system is one of the most in-demand techniques for the seismic isolation of buildings; yet there are still important aspects of its behaviour that need further attention. The CSS system presents variation of friction coefficient, depending on the sliding velocity of the CSS bearings, while friction force and lateral stiffness during the sliding phase are proportional to the axial load. Lateral-torsional response needs to be better understood for base-isolated structures located in near-fault areas, where fling-step and forward-directivity effects can produce long-period (horizontal) velocity pulses. To analyse these aspects, a six-storey reinforced concrete (r.c.) office framed building, with an L-shaped plan and setbacks in elevation, is designed assuming three values of the radius of curvature for the CSS system. Seven in-plan distributions of dynamic-fast friction coefficient for the CSS bearings, ranging from a constant value for all isolators to a different value for each, are considered in the case of low- and medium-type friction properties. The seismic analysis of the test structures is carried out considering an elastic-linear behaviour of the superstructure, while a nonlinear force-displacement law of the CSS bearings is considered in the horizontal direction, depending on sliding velocity and axial load. Given the lack of knowledge of the horizontal direction at which near-fault ground motions occur, the maximum torsional effects and residual displacements are evaluated with reference to different incidence angles, while the orientation of the strongest observed pulses is considered to obtain average values.

  13. Dynamic response analysis of a 24-story damped steel structure

    Science.gov (United States)

    Feng, Demin; Miyama, Takafumi

    2017-10-01

    In Japanese and Chinese building codes, a two-stage design philosophy, damage limitation (small earthquake, Level 1) and life safety (extreme large earthquake, Level 2), is adopted. It is very interesting to compare the design method of a damped structure based on the two building codes. In the Chinese code, in order to be consistent with the conventional seismic design method, the damped structure is also designed at the small earthquake level. The effect of damper systems is considered by the additional damping ratio concept. The design force will be obtained from the damped design spectrum considering the reduction due to the additional damping ratio. The additional damping ratio by the damper system is usually calculated by a time history analysis method at the small earthquake level. The velocity dependent type dampers such as viscous dampers can function well even in the small earthquake level. But, if steel damper is used, which usually remains elastic in the small earthquake, there will be no additional damping ratio achieved. On the other hand, a time history analysis is used in Japan both for small earthquake and extreme large earthquake level. The characteristics of damper system and ductility of the structure can be modelled well. An existing 24-story steel frame is modified to demonstrate the design process of the damped structure based on the two building codes. Viscous wall type damper and low yield steel panel dampers are studied as the damper system.

  14. Using Openstreetmap Data to Generate Building Models with Their Inner Structures for 3d Maps

    Science.gov (United States)

    Wang, Z.; Zipf, A.

    2017-09-01

    With the development of Web 2.0, more and more data related to indoor environments has been collected within the volunteered geographic information (VGI) framework, which creates a need for construction of indoor environments from VGI. In this study, we focus on generating 3D building models from OpenStreetMap (OSM) data, and provide an approach to support construction and visualization of indoor environments on 3D maps. In this paper, we present an algorithm which can extract building information from OSM data, and can construct building structures as well as inner building components (e.g., doors, rooms, and windows). A web application is built to support the processing and visualization of the building models on a 3D map. We test our approach with an indoor dataset collected from the field. The results show the feasibility of our approach and its potentials to provide support for a wide range of applications, such as indoor and outdoor navigation, urban planning, and incident management.

  15. USING OPENSTREETMAP DATA TO GENERATE BUILDING MODELS WITH THEIR INNER STRUCTURES FOR 3D MAPS

    Directory of Open Access Journals (Sweden)

    Z. Wang

    2017-09-01

    Full Text Available With the development of Web 2.0, more and more data related to indoor environments has been collected within the volunteered geographic information (VGI framework, which creates a need for construction of indoor environments from VGI. In this study, we focus on generating 3D building models from OpenStreetMap (OSM data, and provide an approach to support construction and visualization of indoor environments on 3D maps. In this paper, we present an algorithm which can extract building information from OSM data, and can construct building structures as well as inner building components (e.g., doors, rooms, and windows. A web application is built to support the processing and visualization of the building models on a 3D map. We test our approach with an indoor dataset collected from the field. The results show the feasibility of our approach and its potentials to provide support for a wide range of applications, such as indoor and outdoor navigation, urban planning, and incident management.

  16. Seismic Category I Structures Program

    International Nuclear Information System (INIS)

    Endebrock, E.G.; Dove, R.C.; Anderson, C.A.

    1984-01-01

    The Seismic Category I Structures Program currently being carried out at the Los Alamos National Laboratory is sponsored by the Mechanical/Structural Engineering Branch, Division of Engineering Technology of the Nuclear Regulatory Commission (NRC). This project is part of a program designed to increase confidence in the assessment of Category I nuclear power plant structural behavior beyond the design limit. The program involves the design, construction, and testing of heavily reinforced concrete models of auxiliary buildings, fuel-handling buildings, etc., but doe not include the reactor containment building. The overall goal of the program is to supply to the Nuclear Regulatory Commission experimental information and a validated procedure to establish the sensitivity of the dynamic response of these structures to earthquakes of magnitude beyond the design basis earthquake

  17. Dynamic analysis of a reactor building on alluvial soil

    International Nuclear Information System (INIS)

    Arya, A.S.; Chandrasekaran, A.R.; Paul, D.K.

    1977-01-01

    The reactor building consists of reinforced concrete internal framed structure enclosed in double containment shells of prestressed and reinforced concrete all resting on a common massive raft. The external cylindrical shell is capped by a spherical dome while the internal shell carries a cellular grid slab. The building is partially buried under ground. The soil consists of alluvial going to 1000 m depth. The site lies in a moderate seismic zone. The paper presents the dynamic analysis of the building including soil-structure interaction. The mathematical model consists of four parallel, suitably interconnected structures, namely inner containment, outer containment, internal frame and the calandria vault. Each one of the parallel structures consists of lumped-mass beam elements. The soil below the raft and on the sides of outer containment shell is represented by elastic springs in both horizontal and vertical directions. The various assumptions required to be made in developing the mathematical model are briefly discussed in the paper. Transfer matrix technique has been used to determine the frequencies and mode shapes. The deformations due to bending, shear and effect of the rotary inertia have been included. Various alternatives of laterally interconnecting the internals and the shells have been examined and the best alternative from earthquake considerations has been obtained. In the study, the effect of internal structure flexibility and Calandria vault flexibility on the whole building have been studied. The resulting base raft motion and the structural timewise response of all floors have been determined for the design basis (safe shutdown) earthquake by mode superposition

  18. Validation of seismic soil structure interaction (SSI) methodology for a UK PWR nuclear power station

    International Nuclear Information System (INIS)

    Llambias, J.M.

    1993-01-01

    The seismic loading information for use in the seismic design of equipment and minor structures within a nuclear power plant is determined from a dynamic response analysis of the building in which they are located. This dynamic response analysis needs to capture the global response of both the building structure and adjacent soil and is commonly referred to as a soil structure interaction (SSI) analysis. NNC have developed a simple and cost effective methodology for the seismic SSI analysis of buildings in a PWR nuclear power station at a UK soft site. This paper outlines the NNC methodology and describes the approach adopted for its validation

  19. Monitoring of Building Structure by Tiltsensors

    Directory of Open Access Journals (Sweden)

    Alojz Kopáčik

    2005-06-01

    Full Text Available This paper discusses about the dynamic monitoring of stability (tilt measurement of bearing pillar of high-rise building using the electronic measuring system. The electronic measuring system consists of Libela 2800 tilt sensor, input/output device for the AE 2DN tilt sensor, measuring amplifier and also the Spider8 analog/digital converter and the registration equipment (notebook. The basic part of uniaxial tilt sensor creates a frame, on which is among damping plates hung a pendulum (ferromagnetic kernel. The tilt value is determined on a principle of electromagnetic induction by changing the position of ferromagnetic kernel in the reel. The range of pendulum movement is ± 2,5 mm/m and the accuracy of the tilt determination is 0,001 mm/m. The monitored building represents, from the point of constructional view, a ferro-concrete rectangular sceleton, which consists of vertical bearing pillars, on which are guyed longitudinal and transverse girders. The building ground-plan is rectangular with the dimensions of 75 m (distance and 12 m (width. The building has two underground and six above the ground floors with constructional high of 3,40 m. Whole highth of the above ground part of building is 20,4 m. The pillar tilt was measured in the transverse direction of the building at the level of the second floor using the Libela 2800 electronic sensor. The sensor was situated on the metallic console (L-profile, which was assembled on a lateral side of the circuit bearing pillar at the highth of 8,3 m above the ground level. Together with the tilt monitoring, the outside air temperature in the close area of pillar was measured. The tilt measurement was carried out continuously for 168 hours with the recording frequency of 1 Hz (1 measurement/second. The file of the measured data with 603 950 records was reduced to the file with 1006 records, which corresponds to the record of the every tenth minute. The measured tilt values represent from the

  20. Active pipe-embedded structures in buildings for utilizing low-grade energy sources: A review

    International Nuclear Information System (INIS)

    Xu, Xinhua; Wang, Jinbo; Wang, Shengwei; Xiao, Fu

    2010-01-01

    Low-grade energy sources such as geothermal energy, favorable ambient air and industrial waste heat etc. exist widely. Sufficient utilization of these low-grade energy sources may reduce our daily dependence on high-grade energy sources such as electricity resulting in reduced emission of green house gas for environmental conservation. Active pipe-embedded structure as floor/ceiling usually with water as the medium to carry heat or coolth may utilize these low-grade energy sources for providing space air-conditioning. Compact arrangement of pipes in the structure may significantly enlarge heat transfer surface between the slab mass and water in the pipe allowing substantial heat flows even for relatively small temperature differences. Application of the heat or coolth storage capacity of this structure for preheating or pre-cooling is also one among the advantages of this structure for shifting load and exploiting the nighttime cheap electricity tariff in some regions. This paper presents the technology of the active pipe-embedded structure for utilizing widely existing low-grade energy sources following by a comprehensive review on the heat transfer calculation models of this structure and its practical applications in real building systems for space air-conditioning. This review shows that more works on the active structure, especially simple and transient models for dynamic and accurate performance prediction and easy integration with existing building energy simulation packages, are worthwhile for further promoting the practical application wherever the low-grade energy sources are favorable. (author)

  1. Earthquake response of nuclear reactor building deeply embedded in soil

    International Nuclear Information System (INIS)

    Masao, T.; Hirasawa, M.; Yamamoto, S.; Koori, Y.

    1977-01-01

    Regarding the earthquake response of nuclear reactor building embedded in soil, experimental and theoretical investigations has been performed on a model of height-3.75 meter, bottom cross section-5x5 meter, weight-173 ton made of conrete under the financial support of Japanese government (The Science and Technology Agency). The top of model was excited by an eccentric mass vibration that can generate maximum force of 3 tons. Earthpressures were measured at the bottom and side wall of model, and displacements were also measured at the top of model (6 components) and ground surface changed in the steps which were 0, 20, 47, 73, 100% (against the height of model). Using these experimental results and soil properties, dynamical characteristics were studied, including resonant frequency, radiation damping, vibrational mode, frequency response and earthpressure distribution around the model at varying embedment by lumped model, cyclindrical elastic wave model and FEM models (thin layer elements). (Auth.)

  2. Metafier - a Tool for Annotating and Structuring Building Metadata

    DEFF Research Database (Denmark)

    Holmegaard, Emil; Johansen, Aslak; Kjærgaard, Mikkel Baun

    2017-01-01

    in achieving this goal, but often they work as silos. Improving at scale the energy performance of buildings depends on applications breaking these silos and being portable among buildings. To enable portable building applications, the building instrumentation should be supported by a metadata layer...

  3. Long-term monitoring and field testing of an innovative multistory timber building

    Science.gov (United States)

    Omenzetter, Piotr; Morris, Hugh; Worth, Margaret; Kohli, Varun; Uma, S. R.

    2011-04-01

    An innovative three-story timber building, using self-centering, post-tensioned timber shear walls as the main horizontal load resisting system and lightweight composite timber-concrete floors, has recently been completed in Nelson, New Zealand. It is expected to be the trailblazer for similar but taller structures to be more widely adopted. Performance based standards require an advanced understanding of building responses and in order to meet the need for in-situ performance data the building has been subjected to forced vibration testing and instrumented for continuous monitoring using a total of about 90 data channels to capture its dynamic and long-term responses. The first part of the paper presents a brief discussion of the existing research on the seismic performance of timber frame buildings and footfall induced floor vibrations. An outline of the building structural system, focusing on the novel design solutions, is then discussed. This is followed by the description of the monitoring system. The paper emphasizes the need for optimal placement of a limited number of sensors and demonstrates how this was achieved for monitoring floor vibrations with the help of the effective independence-driving point residue (EfI-DPR) technique. A novel approach to the EfI-DPR method proposed here uses a combinatorial search algorithm that increases the chances of obtaining the globally optimal solution. Finally, the results from the forced vibration tests conducted on the whole building at different construction stages are reviewed.

  4. Influence of Structural Periodicity on Vibration Transmission in a Multi-Storey Wooden Building

    DEFF Research Database (Denmark)

    Andersen, Lars Vabbersgaard

    2013-01-01

    Noise is a nuisance to people, and buildings should therefore be designed to prevent propagation of sound and vibration in the audible frequency range as well as the range of frequencies relevant to whole-body vibrations of humans. In heavy structures made of concrete and masonry, a source...

  5. Analysis of the Key and Difficult Points in the Engineering Construction Technology of the Steel Structures of a Super High-rise Building

    Science.gov (United States)

    Dou, Lijun; Li, Hengxu

    2017-07-01

    In recent years, with the rapid development of the economy of China, the traditional building structure has not been able to meet the current people’s demands and the super high-rise building has become a symbol of a city. In the current period, the research on the super high-rise building in the architectural industry of China is late and the technical blanks exist in some construction difficulties in the super high-rise steel structures. Based on the above, a brief analysis and discussion on the difficult construction technology in the steel structures of a super high-rise building and some measures are presented for reference of the relevant personnel in this paper.

  6. Flexible Connection Elastomeric Rubber as a Pounding Resisting Element between Two Adjacent Buildings

    Directory of Open Access Journals (Sweden)

    Yuskar Lase

    2013-03-01

    Full Text Available To solve pounding problem of two adjacent buildings, structural designer usually employs a dilatation between the structures or make the two structures as a monolith structure. Other alternative is by using an elastomeric rubber as a pounding resisting element between the two structures. Effectiveness in applying elastomeric rubber component as flexible connection of two adjacent structures is the main focus of this paper. Various simulations such as structure models, earthquake excitations and openings in gap element are studied. Observation of maximum structural responses will be performed for structure model with elastomeric rubber in comparison with (1 monolith structure model and (2 structure model with rigid element (steel element. Simulation results show that application of elastomeric rubber component to prevent structures from pounding problem provides advantages especially in reducing internal forces in the shorter building. However, it slightly increases displacement of both structures.

  7. Seismic response time history analyses for KALIMER building with a horizontal and vertical seismic isolation

    International Nuclear Information System (INIS)

    Lee, J. H.; Yoo, B.; Koo, K. H.

    2001-01-01

    The seismic response time history analyses for the lumped mass models of KALIMER reactor building with a horizontal and vertical seismic isolation are performed for Artificial Time History and Kobe earthquake. The vertical amplification by the horizontal isolation is reduced by a vertical isolation for both earthquakes. The 3% viscous damping and the vertical isolation frequency of 1.5Hz gives a reduced vertical response compared to the fixed base condition at reactor support, and the 9% viscous damping to Kobe earthquake is required to get an equivalent vertical response with a fixed base condition

  8. Seismic response time history analyses for KALIMER building with a horizontal and vertical seismic isolation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. H.; Yoo, B.; Koo, K. H. [KAERI, Taejon (Korea, Republic of)

    2001-05-01

    The seismic response time history analyses for the lumped mass models of KALIMER reactor building with a horizontal and vertical seismic isolation are performed for Artificial Time History and Kobe earthquake. The vertical amplification by the horizontal isolation is reduced by a vertical isolation for both earthquakes. The 3% viscous damping and the vertical isolation frequency of 1.5Hz gives a reduced vertical response compared to the fixed base condition at reactor support, and the 9% viscous damping to Kobe earthquake is required to get an equivalent vertical response with a fixed base condition.

  9. PROCEDURES FOR SEISMIC CHARACTERIZATION OF TRADITIONAL AND MODERN WOODEN BUILDING TYPES

    Directory of Open Access Journals (Sweden)

    Ario Ceccotti

    2016-03-01

    Full Text Available The paper analyzes different wooden buildings types used in past and nowadays to realized low-rise and mid-rise timber structures from the seismic point of view. A preliminary overview about the procedures prescribed by codes for the seismic characterization of the timber building systems is given. Then the definition of the behaviour q-factor in the literature and its relevance in design of structures in seismic areas is treated. Available research methods for estimating the q-factor based on the verification of the nonlinear seismic response of entire buildings by means of experimental tests and numerical simulations are presented and analyzed. The relevance of a proper definition of the yielding limit and of failure condition in the seismic characterization of wooden building systems is treated. Moreover, a comparison between the q-factor estimations obtained using different calculation methods is presented. Lastly, the appropriate q-factor values are given for a reliable and safe seismic design of buildings realized using the examined wooden constructive systems.

  10. Study on reactor building structure using ultrahigh strength materials - Part 9: Summary of the study

    International Nuclear Information System (INIS)

    Tanaka, H.; Odajima, M.; Irino, K.; Hashiba, T.

    1993-01-01

    Considerations for longevity of nuclear facilities and ease of decommissioning are of great importance for future nuclear power plants. To this end, a concept of an optimal structural concept for nuclear reactor buildings has been studied: the main feature of this concept is to utilize large-sized, light weight prefabricated members with ultrahigh strength materials. The following two items have been selected to study the prospective structure: (1) Applicability of ultrahigh strength materials for reinforced concrete shear walls (2) Construction using large sized prefabricated members As the first step (1), material and structural tests using ultrahigh strength materials, and the subsequent analysis of those tests for reinforced concrete shear walls, has been conducted. The positive results of this study show a bright future for the use of ultrahigh strength materials for the reinforced concrete shear walls of nuclear reactor buildings. As the second step (2), tests on a mixed structure with precasted members have been conducted. Our results positively suggest the use of these materials and methods to improve prospective nuclear power plants. (author)

  11. Dealing with Difference: Building Culturally Responsive Classrooms

    Directory of Open Access Journals (Sweden)

    Nina Burridge

    2009-11-01

    Full Text Available Australia continues to develop as a multicultural society with levels of immigration increasing significantly over recent years as a result of government policies. More recently, the new period of financial turmoil, continuing threats from terrorism and environmental concerns, have all exacerbated the challenges of dealing with difference in our society. In response, schools continue to face the challenges of the impact of a range of different cultures, languages and religions among their student and school communities. How effectively schools deal with difference and how well they are supported in their endeavours to build culturally response classrooms is a perennial issue for both teachers and educators. A major challenge for teachers is to at a minimum, understand cultural differences as they manifest in their particular school settings and to draw on approaches that support student learning in culturally appropriate ways so to assist them to better realise their full potential. In this paper we will consider cultural diversity in the context of recent school policies, highlight a number of frameworks for addressing cultural diversity in the classroom, in particular the approaches by Kalantzis and Cope’s (1999 and Hickling-Hudson (2003. We also draw on the findings from a recent qualitative study of representations of cultural diversity in a number of Sydney metropolitan schools to discuss the need for more greater resource and policy support for progressive teaching approaches that support the development of a more tolerant and inclusive multicultural society. Key words: cultural diversity, schools, teacher education, classroom practice, social inclusion

  12. Study of ex-vessel steam explosion risk of Reactor Pit Flooding System and structural response of containment for CPR1000"+ Unit

    International Nuclear Information System (INIS)

    Zhang Juanhua; Chen Peng

    2015-01-01

    Reactor Pit Flooding System is one of the special mitigation measures for severe accident for CPR1000"+ Unit. If the In-Vessel Relocation function of Reactor Pit Flooding System is failed, there is the steam explosion risk in reactor cavity. This paper firstly adopts MC3D code to build steam explosion model in order to calculate the pressure load and impulses of steam explosion that are as the input data of containment structural response analysis. The next step is to model the containment structure and analyze the structural response by ABAQUS code. The analysis results show that the integral damage induced by steam explosion to the external containment wall is shallow, and the containment structural integrity can be maintained. The risk and damage to the containment integrity reduced by steam explosion of RPF is small, and it does not influence the design and implementation of RPF. (author)

  13. Document turn-over analysis to determine need of NPP construction in build-up structures of reinforced concrete

    International Nuclear Information System (INIS)

    Vojpe, D.K.; Lyubavin, V.K.

    1986-01-01

    Document turn-over to determine used of NPP construction in build-up structures of reinforced concrete is carried out. Ways of improving determination of needs of NPP construction board in the mentioned structures are pointed out

  14. Auxiliary buildings

    International Nuclear Information System (INIS)

    Lakner, I.; Lestyan, E.

    1979-01-01

    The nuclear power station represents a complicated and a particular industrial project. Consequently, the design of the auxiliary buildings serving the power station (offices, kitchen, refreshment room, workshops, depots, water treatment plant building, boiler houses, etc.) requires more attention than usual. This chapter gives a short survey of the auxiliary buildings already completed and discusses the problems of their design, location and structure. (author)

  15. Evaluation of a fast power demand response strategy using active and passive building cold storages for smart grid applications

    International Nuclear Information System (INIS)

    Cui, Borui; Wang, Shengwei; Yan, Chengchu; Xue, Xue

    2015-01-01

    Highlights: • A fast power demand response strategy is developed for smart grid applications. • The developed strategy can provide immediate and stepped power demand reduction. • The demand reduction and building indoor temperature can be predicted accurately. • The demand reduction during the DR event is stable. - Abstract: Smart grid is considered as a promising solution in improving the power reliability and sustainability where demand response is one important ingredient. Demand response (DR) is a set of demand-side activities to reduce or shift electricity use to improve the electric grid efficiency and reliability. This paper presents the investigations on the power demand alternation potential for buildings involving both active and passive cold storages to support the demand response of buildings connected to smart grids. A control strategy is developed to provide immediate and stepped power demand reduction through shutting chiller(s) down when requested. The primary control objective of the developed control strategy is to restrain the building indoor temperature rise as to maintain indoor thermal comfort within certain level during the DR event. The chiller power reduction is also controlled under certain power reduction set-point. The results show that stepped and significant power reduction can be achieved through shutting chiller(s) down when requested. The power demand reduction and indoor temperature during the DR event can be also predicted accurately. The power demand reduction is stable which is predictable for the system operators

  16. Failure behavior of concrete pile and super-structure dynamic response as a result of soil liquefaction during earthquake

    Science.gov (United States)

    Kaneda, Shogo; Hayashi, Kazuhiro; Hachimori, Wataru; Tamura, Shuji; Saito, Taiki

    2017-10-01

    In past earthquake disasters, numerous building structure piles were damaged by soil liquefaction occurring during the earthquake. Damage to these piles, because they are underground, is difficult to find. The authors aim to develop a monitoring method of pile damage based on superstructure dynamic response. This paper investigated the relationship between the damage of large cross section cementitious piles and the dynamic response of the super structure using a centrifuge test apparatus. A dynamic specimen used simple cross section pile models consisting of aluminum rod and mortar, a saturated soil (Toyoura sand) of a relative density of 40% and a super structure model of a natural period of 0.63sec. In the shaking table test under a 50G field (length scale of 1/50), excitation was a total of 3 motions scaled from the Rinkai wave at different amplitudes. The maximum acceleration of each of the excitations was 602gal, 336gal and 299gal. The centrifuge test demonstrated the liquefaction of saturated soil and the failure behavior of piles. In the test result, the damage of piles affected the predominant period of acceleration response spectrum on the footing of the superstructure.

  17. Analysis of the Earthquake-Resistant Design Approach for Buildings in Mexico

    Directory of Open Access Journals (Sweden)

    Carrillo Julián

    2014-01-01

    Full Text Available The development of new codes for earthquake-resistant structures has made possible to guarantee a better performance of buildings, when they are subjected to seismic actions. Therefore, it is convenient that current codes for design of building become conceptually transparent when defining the strength modification factors and assessing maximum lateral displacements, so that the design process can be clearly understood by structural engineers. The aim of this study is to analyze the transparency of earthquake-resistant design approach for buildings in Mexico by means of a critical review of the factors for strength modification and displacement amplification. The approach of building design codes in US is also analyzed. It is concluded that earthquake-resistant design in Mexico have evolved in refinement and complexity. It is also demonstrated that the procedure prescribed by such design codes allows the assessment of the design strengths and displacements in a more rational way, in accordance not only with the present stage of knowledge but also with the contemporary tendencies in building codes. In contrast, the procedures used in US codes may not provide a clear view for seismic response assessment of buildings.

  18. Seismic performance for vertical geometric irregularity frame structures

    Science.gov (United States)

    Ismail, R.; Mahmud, N. A.; Ishak, I. S.

    2018-04-01

    This research highlights the result of vertical geometric irregularity frame structures. The aid of finite element analysis software, LUSAS was used to analyse seismic performance by focusing particularly on type of irregular frame on the differences in height floors and continued in the middle of the building. Malaysia’s building structures were affected once the earthquake took place in the neighbouring country such as Indonesia (Sumatera Island). In Malaysia, concrete is widely used in building construction and limited tension resistance to prevent it. Analysing structural behavior with horizontal and vertical static load is commonly analyses by using the Plane Frame Analysis. The case study of this research is to determine the stress and displacement in the seismic response under this type of irregular frame structures. This study is based on seven-storey building of Clinical Training Centre located in Sungai Buloh, Selayang, Selangor. Since the largest earthquake occurs in Acheh, Indonesia on December 26, 2004, the data was recorded and used in conducting this research. The result of stress and displacement using IMPlus seismic analysis in LUSAS Modeller Software under the seismic response of a formwork frame system states that the building is safe to withstand the ground and in good condition under the variation of seismic performance.

  19. Case study of a not-so-ordinary building - the Cowra Shire administration building ESD refurbishment

    Energy Technology Data Exchange (ETDEWEB)

    Halperin, M.; Arch, B. [Mahalath Halperin Architects Pty Ltd., Armidale (Australia). RAIA Country Division

    2004-07-01

    In refurbishing the Cowra Administration Building, Mahalath Halperin Architects transformed a concrete and glass building of the 1960s into an energy efficient and environmentally responsible building, yet looks to all intents and purposes like an 'ordinary building'. To some, it is simply a newer, nicer building with bright colours, open spaces and a pleasant work environment. But whilst not necessarily being outwardly different in issues of being a 'green building', the resultant building shows that there are many small yet easily achievable ways to be green. That it is not hard, and is in fact beneficial, to reduce energy consumption and overheads, take advantage of the sun (despite its poor orientation) and take on environmental responsibility. (orig.)

  20. Report on workshop to incorporate basin response in the design of tall buildings in the Puget Sound region, Washington

    Science.gov (United States)

    Chang, Susan; Frankel, Arthur D.; Weaver, Craig S.

    2014-01-01

    On March 4, 2013, the City of Seattle and the U.S. Geological Survey (USGS) convened a workshop of 25 engineers and seismologists to provide recommendations to the City for the incorporation of amplification of earthquake ground shaking by the Seattle sedimentary basin in the design of tall buildings in Seattle. The workshop was initiated and organized by Susan Chang, a geotechnical engineer with the City of Seattle Department of Planning and Development, along with Art Frankel and Craig Weaver of the USGS. C.B. Crouse of URS Corporation, Seattle made key suggestions for the agenda. The USGS provided travel support for most of the out-of-town participants. The agenda and invited attendees are given in the appendix. The attendees included geotechnical and structural engineers working in Seattle, engineers with experience utilizing basin response factors in other regions, and seismologists who have studied basin response in a variety of locations. In this report, we summarize the technical presentations and the recommendations from the workshop.

  1. Vibration characteristics of the seismically isolated building supported by the elastomers and the elasto-plastic dampers

    International Nuclear Information System (INIS)

    Mazda, Taiji; Shiojiri, Hiroo; Aoyagi, Sakae; Sawada, Yoshihiro; Kawai, Nobuyasu; Harada, Osamu; Ohtsuka, Susume; Abe, Isamu.

    1989-01-01

    Recently, the seismic isolation has become one of the popular methods in the design of important structures or equipment against the earthquakes. However, the demonstration data on reliability of seismically isolated structures are not enough, therefore it is expected to accumulate such data. Based on the above recognition, the vibration tests of a base isolated building were carried out in Tsukuba Science City. After that, many earthquake records have been obtained at the building, and they made clear the dynamic characteristics of the structure. In order to make clear the dynamic behavior of the building, furthermore, seismic response analyses were executed by using Lumped Mass model, and the results of the analyses roughly agreed with the observed results. (author)

  2. Building a Mechanism for the Function of an Innovation-Oriented Machine-Building Enterprise in Operating the Development

    Directory of Open Access Journals (Sweden)

    Boiarynova Кateryna О.

    2017-07-01

    Full Text Available The article is aimed at developing and substantiating a mechanism for the function of an innovation-oriented machine-building enterprise in operating the development in order to increase effectuality in the space of ecosystem of operation and to satisfy the economic interests of development. The article proposes a mechanism for the function of an innovation-oriented machine-building enterprise in operating the development, its structure and building based on a business model; operating the development through responsibility centers; functional transformation of economic interest of actors in the ecosystem of function into the economic interest of enterprise; use of economic-institutional regulators and management technologies. Implementation of the mechanism would ensure the value of enterprise, the ability to manage development with the prolonged satisfaction of the joint economic interest, the ability to operate the economic interest of actors in the ecosystem, and maintenance the development mode in the operating process. Prospect for further research will be development of technologies for implementation of the proposed mechanism in the machine-building enterprises.

  3. Experimental and analytical studies of a deeply embedded reactor building model considering soil-building interaction. Pt. 3

    International Nuclear Information System (INIS)

    Tanaka, H.

    1983-01-01

    The paper describes the dynamic charachteristics of a deeply embedded reactor building model obtained from the forced vibration tests, earthquake observations and simulation analysis. The earthquake records of the structure and the surrounding soil were examined by using soil-building interaction model as used in the analyses of the forced vibration tests. It is considered that the response of the structure will be influenced by the seismic behaviour of the soil layer as the seismic wave is input to the bedrock of the soil-structure interaction model in the earthquake response analysis. Therefore, dynamic properties of the soil layer during earthquakes were investigated in detail, and applied to the seismic simulation analysis using soil-structure interaction model. Many earthquake records have been obtained since June, 1976 when the earthquake observation system was first established. From these, eight of them which had comparatively large acceleration values were used to investigate the transfer properties of soil layer. Besides, transfer functions computed using in-situ measurement shearing wave velocity showed good agreement with those of the earthquake records. The records of the Miyagiken-oki earthquake of February 20, 1978 (magnitude 6.7) was selected as an example for performing simulation analysis. The simulation analysis are as follows: (1) In the seismic simulation analysis using soil-structure interaction modal, computed results will be in good agreement with the observed ones, when the transfer function of soil layer is properly estimated. (2) Judging from the transfer function of soil layer with the characteristics that the modal damping value decreases gradually at a higher modal frequency, it is found that ddamping of soil-layer can be simulated more adequately by introducing external damping system together with structural damping. (orig./HP)

  4. Dynamic Response of a Floating Bridge Structure

    OpenAIRE

    Viuff, Thomas; Leira, Bernt Johan; Øiseth, Ole; Xiang, Xu

    2016-01-01

    A theoretical overview of the stochastic dynamic analysis of a floating bridge structure is presented. Emphasis is on the wave-induced response and the waves on the sea surface are idealized as a zero mean stationary Gaussian process. The first-order wave load processes are derived using linear potential theory and the structural idealization is based on the Finite Element Method. A frequency response calculation is presented for a simplified floating bridge structure example emphasising the ...

  5. Responses in large-scale structure

    Energy Technology Data Exchange (ETDEWEB)

    Barreira, Alexandre; Schmidt, Fabian, E-mail: barreira@MPA-Garching.MPG.DE, E-mail: fabians@MPA-Garching.MPG.DE [Max-Planck-Institut für Astrophysik, Karl-Schwarzschild-Str. 1, 85741 Garching (Germany)

    2017-06-01

    We introduce a rigorous definition of general power-spectrum responses as resummed vertices with two hard and n soft momenta in cosmological perturbation theory. These responses measure the impact of long-wavelength perturbations on the local small-scale power spectrum. The kinematic structure of the responses (i.e., their angular dependence) can be decomposed unambiguously through a ''bias'' expansion of the local power spectrum, with a fixed number of physical response coefficients , which are only a function of the hard wavenumber k . Further, the responses up to n -th order completely describe the ( n +2)-point function in the squeezed limit, i.e. with two hard and n soft modes, which one can use to derive the response coefficients. This generalizes previous results, which relate the angle-averaged squeezed limit to isotropic response coefficients. We derive the complete expression of first- and second-order responses at leading order in perturbation theory, and present extrapolations to nonlinear scales based on simulation measurements of the isotropic response coefficients. As an application, we use these results to predict the non-Gaussian part of the angle-averaged matter power spectrum covariance Cov{sup NG}{sub ℓ=0}( k {sub 1}, k {sub 2}), in the limit where one of the modes, say k {sub 2}, is much smaller than the other. Without any free parameters, our model results are in very good agreement with simulations for k {sub 2} ∼< 0.06 h Mpc{sup −1}, and for any k {sub 1} ∼> 2 k {sub 2}. The well-defined kinematic structure of the power spectrum response also permits a quick evaluation of the angular dependence of the covariance matrix. While we focus on the matter density field, the formalism presented here can be generalized to generic tracers such as galaxies.

  6. Responses in large-scale structure

    Science.gov (United States)

    Barreira, Alexandre; Schmidt, Fabian

    2017-06-01

    We introduce a rigorous definition of general power-spectrum responses as resummed vertices with two hard and n soft momenta in cosmological perturbation theory. These responses measure the impact of long-wavelength perturbations on the local small-scale power spectrum. The kinematic structure of the responses (i.e., their angular dependence) can be decomposed unambiguously through a ``bias'' expansion of the local power spectrum, with a fixed number of physical response coefficients, which are only a function of the hard wavenumber k. Further, the responses up to n-th order completely describe the (n+2)-point function in the squeezed limit, i.e. with two hard and n soft modes, which one can use to derive the response coefficients. This generalizes previous results, which relate the angle-averaged squeezed limit to isotropic response coefficients. We derive the complete expression of first- and second-order responses at leading order in perturbation theory, and present extrapolations to nonlinear scales based on simulation measurements of the isotropic response coefficients. As an application, we use these results to predict the non-Gaussian part of the angle-averaged matter power spectrum covariance CovNGl=0(k1,k2), in the limit where one of the modes, say k2, is much smaller than the other. Without any free parameters, our model results are in very good agreement with simulations for k2 lesssim 0.06 h Mpc-1, and for any k1 gtrsim 2k2. The well-defined kinematic structure of the power spectrum response also permits a quick evaluation of the angular dependence of the covariance matrix. While we focus on the matter density field, the formalism presented here can be generalized to generic tracers such as galaxies.

  7. Assessment of soil-structure interaction on a 51-story building from the spectral ratio of earthquake recordings

    Directory of Open Access Journals (Sweden)

    Liu Kun-Sung

    2017-01-01

    Full Text Available The soil-structure interaction (SSI can significantly alter the characteristics of recorded motions in buildings. The ratio of Fourier amplitude spectrum of the top-story accelerations to that of the foundation accelerations permits the identification of the natural frequency of the fixed-base building. In this study, records of the Chi-Chi earthquake and the 1226 Hengchun earthquake doublet from the structural array in a 51-story highrise building are used to obtain the dynamic characteristics of the buildings by the transfer function (TF method. As a result, the acceleration amplification of seismic excitation on the 47th storey of buildings is 4.24, in the horizontal component, from the Chi-Chi earthquake data greater than those of the 1226 Hengchun earthquake doublet with a value of 2.82 and 2.06, respectively. In addition, from the spectral ratio of the accelerations (47th floor/basement, together with the Fourier Amplitude Spectrum (FAS of the 47th floor and basement accelerations, it is noted that the peaks of the 47th floor FAS and the spectral ratio appear to coincide with each other from the records of 1226 Hengchun earthquake doublet, suggesting that there is no significant SSI effects in both the longitudinal and transverse directions.

  8. Aspects of mast building and the fine structure of “amphipod silk” glands in Dyopedos bispinis (Amphipoda, Dulichiidae)

    NARCIS (Netherlands)

    Neretin, N.Y.; Zhadan, A.E.; Tzetlin, A.B.

    2017-01-01

    In the present study, we investigated the biology of Dyopedos bispinis, a mast-building amphipod that is abundant near the N. Pertsov White Sea Biological Station. To examine the peculiarities of mast building in Dyopedos bispinis, we studied the social structure of individuals inhabiting the masts

  9. Developing a new library of materials and structural elements for the simulative evaluation of buildings' energy performance

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulos, Agis M.; Oxizidis, Simos; Papathanasiou, Luciano [Laboratory of Heat Transfer and Environmental Engineering, Department of Mechanical Engineering, Aristotle University Thessaloniki, P.O. Box 483, Thessaloniki 54124 (Greece)

    2008-05-15

    Contemporary building energy simulation programs are not only used by researchers but also are common tools in the hands of engineers and architects. Most of them are using databases of materials and structural elements, with characteristics originating from the country or the broader region where the specific program was developed. Thus, often the particularities met in other countries are not considered. Such a database of materials and constructions systematically used in the Greek building sector was developed for use with the simulation program EnergyPlus, which has become quite popular over the last years. In order to determine the applicability of the database, the energy behaviour of a typical multistory, multifamily building was simulated, having the exact materials and structural elements and patterns used in Greece. Furthermore, different thicknesses of insulation were simulated, corresponding to local climatic conditions and, even more important, to different dates of the building's construction. The results are presented and discussed in this paper. (author)

  10. Extracting the building response using seismic interferometry: Theory and application to the Millikan Library in Pasadena, California

    Science.gov (United States)

    Snieder, R.; Safak, E.

    2006-01-01

    The motion of a building depends on the excitation, the coupling of the building to the ground, and the mechanical properties of the building. We separate the building response from the excitation and the ground coupling by deconvolving the motion recorded at different levels in the building and apply this to recordings of the motion in the Robert A. Millikan Library in Pasadena, California. This deconvolution allows for the separation of instrinsic attenuation and radiation damping. The waveforms obtained from deconvolution with the motion in the top floor show a superposition of one upgoing and one downgoing wave. The waveforms obtained by deconvolution with the motion in the basement can be formulated either as a sum of upgoing and downgoing waves, or as a sum over normal modes. Because these deconvolved waves for late time have a monochromatic character, they are most easily analyzed with normal-mode theory. For this building we estimate a shear velocity c = 322 m/sec and a quality factor Q = 20. These values explain both the propagating waves and the normal modes.

  11. Life Comparative Analysis of Energy Consumption and CO2 Emissions of Different Building Structural Frame Types

    Science.gov (United States)

    Kim, Sangyong; Moon, Joon-Ho; Shin, Yoonseok; Kim, Gwang-Hee; Seo, Deok-Seok

    2013-01-01

    The objective of this research is to quantitatively measure and compare the environmental load and construction cost of different structural frame types. Construction cost also accounts for the costs of CO2 emissions of input materials. The choice of structural frame type is a major consideration in construction, as this element represents about 33% of total building construction costs. In this research, four constructed buildings were analyzed, with these having either reinforced concrete (RC) or steel (S) structures. An input-output framework analysis was used to measure energy consumption and CO2 emissions of input materials for each structural frame type. In addition, the CO2 emissions cost was measured using the trading price of CO2 emissions on the International Commodity Exchange. This research revealed that both energy consumption and CO2 emissions were, on average, 26% lower with the RC structure than with the S structure, and the construction costs (including the CO2 emissions cost) of the RC structure were about 9.8% lower, compared to the S structure. This research provides insights through which the construction industry will be able to respond to the carbon market, which is expected to continue to grow in the future. PMID:24227998

  12. Life Comparative Analysis of Energy Consumption and CO2 Emissions of Different Building Structural Frame Types

    Directory of Open Access Journals (Sweden)

    Sangyong Kim

    2013-01-01

    Full Text Available The objective of this research is to quantitatively measure and compare the environmental load and construction cost of different structural frame types. Construction cost also accounts for the costs of CO2 emissions of input materials. The choice of structural frame type is a major consideration in construction, as this element represents about 33% of total building construction costs. In this research, four constructed buildings were analyzed, with these having either reinforced concrete (RC or steel (S structures. An input-output framework analysis was used to measure energy consumption and CO2 emissions of input materials for each structural frame type. In addition, the CO2 emissions cost was measured using the trading price of CO2 emissions on the International Commodity Exchange. This research revealed that both energy consumption and CO2 emissions were, on average, 26% lower with the RC structure than with the S structure, and the construction costs (including the CO2 emissions cost of the RC structure were about 9.8% lower, compared to the S structure. This research provides insights through which the construction industry will be able to respond to the carbon market, which is expected to continue to grow in the future.

  13. Structural Response to Blast Loading: The Effects of Corrosion on Reinforced Concrete Structures

    Directory of Open Access Journals (Sweden)

    Hakan Yalciner

    2014-01-01

    Full Text Available Structural blast design has become a necessary part of the design with increasing terrorist attacks. Terrorist attacks are not the one to make the structures important against blast loading where other explosions such as high gas explosions also take an important place in structural safety. The main objective of this study was to verify the structural performance levels under the impact of different blast loading scenarios. The blast loads were represented by using triangular pulse for single degree of freedom system. The effect of blast load on both corroded and uncorroded reinforced concrete buildings was examined for different explosion distances. Modified plastic hinge properties were used to ensure the effects of corrosion. The results indicated that explosion distance and concrete strength were key parameters to define the performance of the structures against blast loading.

  14. Conceptual optimization using genetic algorithms for tube in tube structures

    International Nuclear Information System (INIS)

    Pârv, Bianca Roxana; Hulea, Radu; Mojolic, Cristian

    2015-01-01

    The purpose of this article is to optimize the tube in tube structural systems for tall buildings under the horizontal wind loads. It is well-known that the horizontal wind loads is the main criteria when choosing the structural system, the types and the dimensions of structural elements in the majority of tall buildings. Thus, the structural response of tall buildings under the horizontal wind loads will be analyzed for 40 story buildings and a total height of 120 meters; the horizontal dimensions will be 30m × 30m for the first two optimization problems and 15m × 15m for the third. The optimization problems will have the following as objective function the cross section area, as restrictions the displacement of the building< the admissible displacement (H/500), and as variables the cross section dimensions of the structural elements

  15. Thermo active piles and diaphragm walls building process and thermal response test; Pilotes y pantallas termoactivas. Proceso constructivo y caracterizacion termica

    Energy Technology Data Exchange (ETDEWEB)

    Mazariegos, A.; Anton, L. C.; Valle, R.; Urchueguia, J.; Quilis, S.; Martinez, S.; Magraner, T.

    2009-07-01

    Thermo active foundation technology uses building foundation piles diaphragm wall slabs as ground heat exchangers to provide building with heating and cooling. This type of foundation is based on the use of the ground temperature to enhance the heat pump coefficient of performance (COP). In this kind of structures, the heat exchange can be done through a closed circuit installed on the reinforced of the foundation. This closed circuit is made up of HDPE pipes geothermal probes, through which water or brine circulates producing a heat exchange between this fluid and the ground. this fluid is led to a geothermal heat pump GHP, generating the energy required for air-conditioning a building. ENERGESIS, leading company in the air-conditioning field using geothermal energy and RADIO KRONSA, leading company in the engineering field of soil and subsoil, with the collaboration of the Universidad Politecnica de Valencia (UPV) and the Escuela Universitaria de Ingenieria Tecnica de Obras Publicas (UPM), have developed an action line to design and implement saving energy facilities by using geothermal energy associated with the foundations. A series of tests at work have been done in order to have a procedure to implement the thermal response of thermo active piles and diaphragm walls. (Author) 7 refs.

  16. Coupling of impedance functions to nuclear reactor building for soil-structure interaction analysis

    International Nuclear Information System (INIS)

    Danisch, R.; Delinic, K.; Trbojevic, V.M.

    1991-01-01

    Finite element model of a nuclear reactor building is coupled to complex soil impedance functions and soil-structure-interaction analysis is carried out in frequency domain. In the second type of analysis applied in this paper, soil impedance functions are used to evaluate equivalent soil springs and dashpots of soil. These are coupled to the structure model in order to carry out the time marching analysis. Three types of soil profiles are considered: hard, medium and soft. Results of two analyzes are compared on the same structural model. Equivalent soil springs and dashpots are determined using new method based on the least square approximation. (author)

  17. The numerical computation of seismic fragility of base-isolated Nuclear Power Plants buildings

    International Nuclear Information System (INIS)

    Perotti, Federico; Domaneschi, Marco; De Grandis, Silvia

    2013-01-01

    Highlights: • Seismic fragility of structural components in base isolated NPP is computed. • Dynamic integration, Response Surface, FORM and Monte Carlo Simulation are adopted. • Refined approach for modeling the non-linearities behavior of isolators is proposed. • Beyond-design conditions are addressed. • The preliminary design of the isolated IRIS is the application of the procedure. -- Abstract: The research work here described is devoted to the development of a numerical procedure for the computation of seismic fragilities for equipment and structural components in Nuclear Power Plants; in particular, reference is made, in the present paper, to the case of isolated buildings. The proposed procedure for fragility computation makes use of the Response Surface Methodology to model the influence of the random variables on the dynamic response. To account for stochastic loading, the latter is computed by means of a simulation procedure. Given the Response Surface, the Monte Carlo method is used to compute the failure probability. The procedure is here applied to the preliminary design of the Nuclear Power Plant reactor building within the International Reactor Innovative and Secure international project; the building is equipped with a base isolation system based on the introduction of High Damping Rubber Bearing elements showing a markedly non linear mechanical behavior. The fragility analysis is performed assuming that the isolation devices become the critical elements in terms of seismic risk and that, once base-isolation is introduced, the dynamic behavior of the building can be captured by low-dimensional numerical models

  18. TEACHING OPTIMIZATION OF STUDENTS AT DESIGN OF BUILDINGS AND STRUCTURES FOUNDATIONS

    Directory of Open Access Journals (Sweden)

    MISURA Lid. V.

    2016-04-01

    Full Text Available Raising of problem. According to world statistics, more than 75 % of all violations of the normal operation of buildings and structures is due to deficiencies in the design, construction and operation of bases and foundations [1]. The costs to eliminate these negative effects can be compared only with the initial cost of construction, it speaks about the relevance of teaching subjects related to the design of foundations. On the other hand increased demands on the students' knowledge, raises the amount of information that needs to absorb at constant periods of instruction, which makes the current process optimization study of these disciplines. Purpose. The aim of the article is to present the software package that allows to facilitate and accelerate the calculation and check the parameters of foundations and bases for the design of buildings and structures. The software product is designed as an educational complex, which allows the student to help with the calculations in different levels of difficulty and test his knowledge. Conclusion. The program complex, which consists of a program for dimensioning the foundations, the program for calculating the parameters of the bases, of the database. It is confirmed stable operation of the school complex (the program, measures were taken to test the program, helped to make it stable. The training complex is designed only for shallow foundations, so the work will be continued.

  19. PHYSICAL AND MECHANICAL CHARACTERISTICS OF BUILDING MATERIALS OF HISTORIC BUILDINGS

    Directory of Open Access Journals (Sweden)

    Jiří Witzany

    2017-12-01

    Full Text Available The article presents partial results of laboratory research into physical and mechanical characteristics of materials most commonly used as walling units in masonry structures of historic and heritage buildings. Core boreholes and specimens for the laboratory research of selected characteristics were sampled from accessible places of historic buildings, which had not been restored or reconstructed. The results of the research brought new knowledge about the unreliability (variance of the properties of historical, mainly natural building materials, and, at the same time, pointed out the need for further research and extension of knowledge necessary for the assessment of residual physical and mechanical characteristics of historic masonry structures.

  20. DIGITAL PRESERVATION OF THE QUON SANG LUNG LAUNDRY BUILDING, FORT MACLEOD, ALBERTA

    Directory of Open Access Journals (Sweden)

    P. Dawson

    2017-08-01

    Full Text Available This paper describes the results of an emergency recording and archiving of a historic structure in Southern Alberta and explores the lessons learned. Digital recording of the Quon Sang Lung Laundry building in Fort Macleod, Alberta, was a joint initiative between Alberta Culture and Tourism and the University of Calgary. The Quon Sang Lung Laundry was a boomtown-style wood structure situated in the Fort Macleod Provincial Historic Area, Alberta. Built in the mid-1800s, the structure was one of the four buildings comprising Fort Macleod’s Chinatown. Its association with Chinese immigration, settlement, and emergence of Chinese-owned businesses in early twentieth-century Alberta, made the Quon Sang Lung Laundry a unique and very significant historic resource. In recent years, a condition assessment of the structure indicated that the building was not safe and that the extent of the instability could lead to a sudden collapse. In response, Alberta Culture and Tourism engaged the Departments of Anthropology and Archaeology and Geomatics Engineering from the University of Calgary, to digitally preserve the laundry building. A complete survey including the laser scanning of all the remaining elements of the original structure, was undertaken. Through digital modeling, the work guarantees that a three-dimensional representation of the building is available for future use. This includes accurate 3D renders of the exterior and interior spaces and a collection of architectural drawings comprising floor plans, sections, and elevations.