WorldWideScience

Sample records for strongly stained vessels

  1. Segmentation of elastic fibres in images of vessel wall sections stained with Weigert's resorcin-fuchsin.

    Science.gov (United States)

    Hernández-Morera, Pablo; Travieso-González, Carlos M; Castaño-González, Irene; Mompeó-Corredera, Blanca; Ortega-Santana, Francisco

    2017-04-01

    The elastic fibres are an essential component of the extracellular matrix in blood vessel walls that allows a long-range of deformability and passive recoil without energy input. The quantitative determination of elastic fibres will provide information on the state of the vascular wall and to determine the role and behaviour of this key structural element in different physiological and pathological vascular processes. We present a segmentation method to identify and quantify elastic fibres based on a local threshold technique and some morphological characteristics measured on the segmented objects that facilitate the discrimination between elastic fibres and other image components. The morphological characteristics analysed are the thickness and the length of an object. The segmentation method was evaluated using an image database of vein sections stained with Weigert's resorcin-fuchsin. The performance results are based on a ground truth generated manually resulting in values of sensitivity greater than 80% with the exception in two samples, and specificity values above 90% for all samples. Medical specialists carried out a visual evaluation where the observations indicate a general agreement on the segmentation results' visual quality, and the consistency between the methodology proposed and the subjective observation of the doctors for the evaluation of pathological changes in vessel wall. The proposed methodology provides more objective measurements than the qualitative methods traditionally used in the histological analysis, with a significant potential for this method to be used as a diagnostic aid for many other vascular pathological conditions and in similar tissues such as skin and mucous membranes. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Infrared tomography for diagnostic imaging of port wine stain blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Goodman, D. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    The objective of this work is the development of Infrared Tomography (IRT) for detecting and characterizing subsurface chromophores in human skin. Characterization of cutaneous chromophores is crucial for advances in the laser treatment of pigmented lesions (e.g., port wine stain birthmarks and tatoos). Infrared tomography (IRT) uses a fast infrared focal plane array (IR-FPA) to detect temperature rises in a substrate induced by pulsed radiation. A pulsed laser is used to produce transient heating of an object. The temperature rise, due to the optical absorption of the pulsed laser light, creates an increase in infrared emission which is measured by the IR-FPA. Although the application of IRT to image subsurface cracks due to metal fatigue is a topic of great interest in the aircraft industry, the application to image subsurface chromophores in biological materials is novel. We present an image recovery method based on a constrained conjugate gradient algorithm that has obtained the first ever high quality images of port wine blood vessels.

  3. Safety analysis of nuclear containment vessels subjected to strong earthquakes and subsequent tsunamis

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Feng; Li, Hong Zhi [Dept. Structural Engineering, Tongji University, Shanghai (China)

    2017-08-15

    Nuclear power plants under expansion and under construction in China are mostly located in coastal areas, which means they are at risk of suffering strong earthquakes and subsequent tsunamis. This paper presents a safety analysis for a new reinforced concrete containment vessel in such events. A finite element method-based model was built, verified, and first used to understand the seismic performance of the containment vessel under earthquakes with increased intensities. Then, the model was used to assess the safety performance of the containment vessel subject to an earthquake with peak ground acceleration (PGA) of 0.56g and subsequent tsunamis with increased inundation depths, similar to the 2011 Great East earthquake and tsunami in Japan. Results indicated that the containment vessel reached Limit State I (concrete cracking) and Limit State II (concrete crushing) when the PGAs were in a range of 0.8–1.1g and 1.2–1.7g, respectively. The containment vessel reached Limit State I with a tsunami inundation depth of 10 m after suffering an earthquake with a PGA of 0.56g. A site-specific hazard assessment was conducted to consider the likelihood of tsunami sources.

  4. Compared With Elastin Stains, h-Caldesmon and Desmin Offer Superior Detection of Vessel Invasion in Gastric, Pancreatic, and Colorectal Adenocarcinomas.

    Science.gov (United States)

    Ekinci, Özgür; Öğüt, Betül; Çelik, Bülent; Dursun, Ayşe

    2018-01-01

    The presence of vessel invasion is considered indicative of a poor prognosis in many malignant tumors. We aimed to compare the sensitivity of elastin stains (van Gieson's and orcein methods) with 2 smooth muscle markers (h-caldesmon and desmin) in gastric, pancreatic, and colorectal adenocarcinoma specimens. We used 27 (29.3%) gastric, 35 (38.0%) pancreatic, and 30 (32.6%) colorectal resection specimens. We applied a provisional classification of vessel invasion patterns: type A, a focus with a nearby artery unaccompanied by a vein; type T, a focus at the invasive front without an unaccompanied artery; and type X, foci that only appeared by any of the 4 stains used. There were 369 foci. The smooth muscle markers were more sensitive than the elastin stains, and h-caldesmon more sensitive than desmin, in all types. Among the 139 type A foci, 33 (23.7%) were positive by desmin and h-caldesmon, whereas the elastin stains were not ( P = .001). h-Caldesmon was the only positive marker in 11 (7.9%; P = .011). Among the 78 type T foci, 21 (26.9%) were positive by desmin and h-caldesmon, when both elastin stains were negative ( P = .000). In 16 (20.5%) foci, h-caldesmon was the only positive marker ( P = .002). Among 152 type X foci, 91 (59.9%) were positive by all markers, 26 (17.1%) by both desmin and h-caldesmon, and 9 (5.9%) by only the 2 elastin stains ( P = .001). We recommend these stains for suspect foci in gastric, pancreatic, and colorectal adenocarcinoma specimens. They might highlight both predictable and unpredictable foci.

  5. Intravenous injection of artificial red cells and subsequent dye laser irradiation causes deep vessel impairment in an animal model of port-wine stain.

    Science.gov (United States)

    Rikihisa, Naoaki; Tominaga, Mai; Watanabe, Shoji; Mitsukawa, Nobuyuki; Saito, Yoshiaki; Sakai, Hiromi

    2018-03-15

    Our previous study proposed using artificial blood cells (hemoglobin vesicles, Hb-Vs) as photosensitizers in dye laser treatment for port-wine stains (PWSs). Dye laser photons are absorbed by red blood cells (RBCs) and hemoglobin (Hb) mixture, which potentially produce more heat and photocoagulation and effectively destroy endothelial cells. Hb-Vs combination therapy will improve clinical outcomes of dye laser treatment for PWSs because very small vessels do not contain sufficient RBCs and they are poor absorbers/heaters of lasers. In the present study, we analyzed the relationship between vessel depth from the skin surface and vessel distraction through dye laser irradiation following intravenous Hb-Vs injection using a chicken wattle model. Hb-Vs were administered and chicken wattles underwent high-energy irradiation at energy higher than in the previous experiments. Hb-Vs location in the vessel lumen was identified to explain its photosensitizer effect using human Hb immunostaining of the irradiated wattles. Laser irradiation with Hb-Vs can effectively destroy deep vessels in animal models. Hb-Vs tend to flow in the marginal zone of both small and large vessels. Increasing laser power combined with Hb-Vs injection contributed for deep vessel impairment because of the synergetic effect of both methods. Newly added Hb tended to flow near the target endothelial cells of the laser treatment. In Hb-Vs and RBC mixture, heat transfer to endothelial cells from absorbers/heater may increase. Hb-Vs function as photosensitizers to destroy deep vessels within a restricted distance that the photon can reach.

  6. Sensitivity of Helicobacter pylori detection by Giemsa staining is poor in comparison with immunohistochemistry and fluorescent in situ hybridization and strongly depends on inflammatory activity.

    Science.gov (United States)

    Kocsmár, Éva; Szirtes, Ildikó; Kramer, Zsófia; Szijártó, Attila; Bene, László; Buzás, György Miklós; Kenessey, István; Bronsert, Peter; Csanadi, Agnes; Lutz, Lisa; Werner, Martin; Wellner, Ulrich Friedrich; Kiss, András; Schaff, Zsuzsa; Lotz, Gábor

    2017-08-01

    Conventional stainings (including H&E and special stains like Giemsa) are the most widely applied histopathologic detection methods of Helicobacter pylori (HP). We aimed to compare the diagnostic performance of Giemsa staining with immunohistochemistry (IHC) and fluorescent in situ hybridization (FISH) on a monocentric cohort of 2896 gastric biopsies and relate results to histologic alterations in order to find such histopathologic subgroups in which these methods underperform. All cases were categorized regarding presence or absence of chronic gastritis, inflammatory activity, and mucosal structural alterations. Giemsa revealed 687 cases (23.7%), IHC 795 cases (27.5%), and FISH 788 cases (27.2%) as being HP positive. Giemsa showed significantly lower overall sensitivity (83.3%) compared to IHC (98.8%) and FISH (98.0%). Moreover, the sensitivity of Giemsa dramatically dropped to 33.6% in the nonactive cases. We found that sensitivity of Giemsa strongly depends on HP density and, accordingly, on the presence of activity. Structural alterations (intestinal metaplasia, atrophy, etc.) had only no or weak effect on sensitivity of the three stainings. Both IHC and FISH proved to be equally reliable HP detecting techniques whose diagnostic performance is minimally influenced by mucosal inflammatory and structural alterations contrary to conventional stainings. We highly recommend immunohistochemistry for clinically susceptible, nonactive chronic gastritis cases, if the conventional stain-based HP detection is negative. Moreover, we recommend to use IHC more widely as basic HP stain. Helicobacter pylori FISH technique is primarily recommended to determine bacterial clarithromycin resistance. Furthermore, it is another accurate diagnostic tool for HP. © 2017 John Wiley & Sons Ltd.

  7. Gram staining.

    Science.gov (United States)

    Coico, Richard

    2005-10-01

    Named after Hans Christian Gram who developed the method in 1884, the Gram stain allows one to distinguish between Gram-positive and Gram-negative bacteria on the basis of differential staining with a crystal violet-iodine complex and a safranin counterstain. The cell walls of Gram-positive organisms retain this complex after treatment with alcohol and appear purple, whereas gram-negative organisms decolorize following such treatment and appear pink. The method described here is useful for assessing bacterial contamination of tissue culture samples or for examining the Gram stain status and morphological features of bacteria isolated from mixed or isolated bacterial cultures.

  8. Cholinergic innervation of human mesenteric lymphatic vessels.

    Science.gov (United States)

    D'Andrea, V; Bianchi, E; Taurone, S; Mignini, F; Cavallotti, C; Artico, M

    2013-11-01

    The cholinergic neurotransmission within the human mesenteric lymphatic vessels has been poorly studied. Therefore, our aim is to analyse the cholinergic nerve fibres of lymphatic vessels using the traditional enzymatic techniques of staining, plus the biochemical modifications of acetylcholinesterase (AChE) activity. Specimens obtained from human mesenteric lymphatic vessels were subjected to the following experimental procedures: 1) drawing, cutting and staining of tissues; 2) staining of total nerve fibres; 3) enzymatic staining of cholinergic nerve fibres; 4) homogenisation of tissues; 5) biochemical amount of proteins; 6) biochemical amount of AChE activity; 6) quantitative analysis of images; 7) statistical analysis of data. The mesenteric lymphatic vessels show many AChE positive nerve fibres around their wall with an almost plexiform distribution. The incubation time was performed at 1 h (partial activity) and 6 h (total activity). Moreover, biochemical dosage of the same enzymatic activity confirms the results obtained with morphological methods. The homogenates of the studied tissues contain strong AChE activity. In our study, the lymphatic vessels appeared to contain few cholinergic nerve fibres. Therefore, it is expected that perivascular nerve stimulation stimulates cholinergic nerves innervating the mesenteric arteries to release the neurotransmitter AChE, which activates muscarinic or nicotinic receptors to modulate adrenergic neurotransmission. These results strongly suggest, that perivascular cholinergic nerves have little or no effect on the adrenergic nerve function in mesenteric arteries. The cholinergic nerves innervating mesenteric arteries do not mediate direct vascular responses.

  9. Pleural fluid Gram stain

    Science.gov (United States)

    Gram stain of pleural fluid ... mixing it with a violet stain (called a Gram stain). A laboratory specialist uses a microscope to ... reveals an abnormal collection of pleural fluid. The Gram stain can help identify the bacteria that might ...

  10. Differential staining of bacteria: gram stain.

    Science.gov (United States)

    Moyes, Rita B; Reynolds, Jackie; Breakwell, Donald P

    2009-11-01

    In 1884, Hans Christian Gram, a Danish doctor, developed a differential staining technique that is still the cornerstone of bacterial identification and taxonomic division. This multistep, sequential staining protocol separates bacteria into four groups based on cell morphology and cell wall structure: Gram-positive cocci, Gram-negative cocci, Gram-positive rods, and Gram-negative rods. The Gram stain is useful for assessing bacterial contamination of tissue culture samples or for examining the Gram stain status and morphological features of bacteria isolated from mixed or isolated bacterial cultures. (c) 2009 by John Wiley & Sons, Inc.

  11. Port-Wine Stains

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Port-Wine Stains KidsHealth / For Parents / Port-Wine Stains What's ... Manchas de vino de oporto What Are Port-Wine Stains? A port-wine stain is a type ...

  12. Acid-fast stain

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003766.htm Acid-fast stain To use the sharing features on this page, please enable JavaScript. The acid-fast stain is a laboratory test that determines ...

  13. Stabilized Romanowsky blood stain.

    Science.gov (United States)

    Gilliland, J W; Dean, W W; Stastny, M; Lubrano, G J

    1979-05-01

    It has been shown that the degradation of thiazine dyes which normally occurs in methanolic solution, as in the case of Romanowsky blood stains, can be prevented by making the solution acidic. In a certain range of acidity, the stain precipitates in the form of monothiazine eosinate, but by making the solution sufficiently acidic, eosin is protonated and the precipitate cannot form. These observations have been used to develop a blood stain which is stable, even at elevated temperatures, for several months. For use the stain is neutralized by a specially formulated fixative solution.

  14. Iron Stain on Wood

    Science.gov (United States)

    Mark Knaebe

    2013-01-01

    Iron stain, an unsightly blue–black or gray discoloration, can occur on nearly all woods. Oak, redwood, cypress, and cedar are particularly prone to iron stain because these woods contain large amounts of tannin-like extractives. The discoloration is caused by a chemical reaction between extractives in the wood and iron in steel products, such as nails, screws, and...

  15. Endocervical gram stain

    Science.gov (United States)

    ... no symptoms. Alternative Names Gram stain of cervix; Gram stain of cervical secretions References Marrazzo JM, Apicella MA. Neisseria gonorrhoeae (gonorrhea). In: Bennett JE, Dolin R, Blaser MJ, eds. Mandell, Douglas, and Bennett's Principles and Practice of Infectious Diseases, Updated Edition . 8th ...

  16. Dramatic Stained Glass.

    Science.gov (United States)

    Prater, Michael

    2002-01-01

    Describes an art project that is appropriate for students in fifth through twelfth grade in which they create Gothic-style stained-glass windows. Discusses how college students majoring in elementary education created stained-glass windows. Addresses how to adapt this lesson for younger students. (CMK)

  17. Lasers or light sources for treating port-wine stains

    DEFF Research Database (Denmark)

    Faurschou, Annesofie; Olesen, Anne Braae; Leonardi-Bee, Jo

    2011-01-01

    Port-wine stains are birthmarks caused by malformations of blood vessels in the skin. Port-wine stains manifest themselves in infancy as a flat, red mark and do not regress spontaneously but may, if untreated, become darker and thicker in adult life. The profusion of various lasers and light...

  18. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  19. Stool Gram stain

    Science.gov (United States)

    ... of stool; Feces Gram stain References Allos BM. Campylobacter infections. In: Goldman L, Schafer AI, eds. Goldman- ... Bacterial Infections Read more Foodborne Illness Read more Gastroenteritis Read more A.D.A.M., Inc. is ...

  20. "Stained Glass" Landscape Windows

    Science.gov (United States)

    Vannata, Janine

    2008-01-01

    Both adults and children alike marvel at the grand vivid stained-glass windows created by American artist Louis Comfort Tiffany. Today he is commonly recognized as one of America's most influential designers and artists throughout the last nineteenth and early twentieth century. In the lesson described in this article, students created their own…

  1. Stained Glass and Flu

    Centers for Disease Control (CDC) Podcasts

    2017-02-01

    Dr. Robert Webster, an Emeritus member of the Department of Infectious Diseases at St. Jude Children's Research Hospital, discusses his cover art story on stained glass and influenza.  Created: 2/1/2017 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 2/1/2017.

  2. Port-wine stain

    Science.gov (United States)

    ... About MedlinePlus Show Search Search MedlinePlus GO GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Port-wine stain URL of this page: //medlineplus.gov/ency/ ...

  3. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    The role of the research vessels as a tool for marine research and exploration is very important. Technical requirements of a suitable vessel and the laboratories needed on board are discussed. The history and the research work carried out...

  4. Optical Monte Carlo modeling of a true portwine stain anatomy

    Science.gov (United States)

    Barton, Jennifer K.; Pfefer, T. Joshua; Welch, Ashley J.; Smithies, Derek J.; Nelson, Jerry; van Gemert, Martin J.

    1998-04-01

    A unique Monte Carlo program capable of accommodating an arbitrarily complex geometry was used to determine the energy deposition in a true port wine stain anatomy. Serial histologic sections taken from a biopsy of a dark red, laser therapy resistant stain were digitized and used to create the program input for simulation at wavelengths of 532 and 585 nm. At both wavelengths, the greatest energy deposition occurred in the superficial blood vessels, and subsequently decreased with depth as the laser beam was attenuated. However, more energy was deposited in the epidermis and superficial blood vessels at 532 nm than at 585 nm.

  5. Ghost mycobacteria on Gram stain.

    Science.gov (United States)

    Trifiro, S; Bourgault, A M; Lebel, F; René, P

    1990-01-01

    The Gram stain is a key tool in diagnostic microbiology. Its usefulness with respect to mycobacteria is undefined. The neutrality of mycobacteria other than Mycobacterium tuberculosis on Gram staining of various clinical specimens is described. Images PMID:1688872

  6. Ghost mycobacteria on Gram stain.

    OpenAIRE

    Trifiro, S; Bourgault, A M; Lebel, F; René, P

    1990-01-01

    The Gram stain is a key tool in diagnostic microbiology. Its usefulness with respect to mycobacteria is undefined. The neutrality of mycobacteria other than Mycobacterium tuberculosis on Gram staining of various clinical specimens is described.

  7. Gram stain of urethral discharge

    Science.gov (United States)

    Urethral discharge Gram stain; Urethritis - Gram stain ... Augenbraun MH, McCormack WM. Urethritis. In: Bennett JE, Dolin R, Blaser MJ, eds. Mandell, Douglas, and Bennett's Principles and Practice of Infectious Diseases, Updated Edition . ...

  8. Staining properties and stability of a standardised Romanowsky stain.

    Science.gov (United States)

    Marshall, P N; Bentley, S A; Lewis, S M

    1978-03-01

    An evaluation of the standardised Romanowsky stain of Marshall et al. has been made in a routine haematology laboratory. It was noted that this stain had several advantages over the May-Grünwald Giemsa stain used in most British laboratories. These advantages include ease and speed of preparation, a shorter staining time, and reproducibility of results. These results are described in detail. The stability of the stock stain solution and of the 'working' stain (stock + buffer) has been studied by, respectively, thin-layer chromatography and visible spectroscopy. No change was detected in the composition of the stock solution at ambient temperature over a period of six months. Stability was unaffected by the composition of the container (polyethylene, PyrexTM, or soda-glass) or by daylight. The 'working' solution was stable for 3 hours. Thereafter a precipitate is formed, consisting of thiazine dyes and eosin in a molar ratio of approximately 2:1.

  9. Network of endocardial vessels.

    Science.gov (United States)

    Lee, Byung-Cheon; Kim, Hong Bae; Sung, Baeckkyoung; Kim, Ki Woo; Sohn, Jamin; Son, Boram; Chang, Byung-Joon; Soh, Kwang-Sup

    2011-01-01

    Although there have been reports on threadlike structures inside the heart, they have received little attention. We aimed to develop a method for observing such structures and to reveal their ultrastructures. An in situ staining method, which uses a series of procedures of 0.2-0.4% trypan blue spraying and washing, was applied to observe threadlike structures on the surfaces of endocardia. The threadlike structures were isolated and observed by using confocal laser scanning microscopy (CLSM) and transmission electron microscopy (TEM). Networks of endocardial vessels (20 μm in thickness) with expansions (40-100 μm in diameter) were visualized; they were movable on the endocardium of the bovine atrium and ventricle. CLSM showed that (1) rod-shaped nuclei were aligned along the longitudinal direction of the endocardial vessel and (2) there were many cells inside the expansion. TEM on the endocardial vessel revealed that (1) there existed multiple lumens (1-7 μm in diameter) and (2) the extracellular matrices mostly consisted of collagen fibers, which were aligned along the longitudinal direction of the endocardial vessel or were locally organized in reticular structures. We investigated the endocardial circulatory system in bovine cardiac chambers and its ultrastructures, such as nucleic distributions, microlumens, and collagenous extracellular matrices. Copyright © 2011 S. Karger AG, Basel.

  10. A new bacterial staining method involving Gram stain with theoretical considerations of the staining mechanism.

    Science.gov (United States)

    Noda, Y; Tôei, K

    1992-01-01

    In order to investigate the mechanism of Gram staining of bacteria, tests with anionic dyes followed by treatment with cationic octyltrimethylammonium (OTMA) were carried out. The study revealed that tetrabromophenolphthalein ethylester (TBPE) gave the most reliable staining of Gram-negative bacteria with negative staining of Gram-positive bacteria. Tests on many species of bacteria showed that TBPE positive bacteria were Gram-negative and vice versa, without exception.

  11. Factors influencing extract of Hibiscus sabdariffa staining of rat testes.

    Science.gov (United States)

    Bassey, R B; Bakare, A A; Peter, A I; Oremosu, A A; Osinubi, A A

    2012-08-01

    Some plant extracts can be used in biology and medicine to reveal or identify cellular components and tissues. We investigated the effects of time and concentration on staining of histological sections of rat testes by an acidified extract of Hibiscus sabdariffa. An ethanolic extract of H. sabdariffa was diluted using 1% acetic acid in 70% ethanol to stain histological sections of testes at concentrations of 0.2, 0.1 and 0.05 g/ml for 5, 10, 15, 30, 45 and 60 min. The sections of testes were stained deep red. The staining efficiency of H. sabdariffa was greater at a high concentration and required less time to achieve optimal staining. H. sabdariffa is a strongly basic dye that can be used for various diagnostic purposes. Staining time and concentration must be considered to achieve optimal results.

  12. An evaluation of some commerical Romanowsky stains.

    Science.gov (United States)

    Marshall, P N; Bentley, S A; Lewis, S M

    1975-08-01

    The staining properties of 43 commerical Romanowsky-type stains have been studied. Considerable differences in the appearance of stained blood films were observed with different batches of these stains, the staining of red cells being particularly variable. Attempts have been made to correlate staining patterns with stain composition as revealed by thin-layer chromatography and sulphated ash analyses. In this way it has been possible to define some essential requirements for satisfactory staining.

  13. Peri-stent contrast staining, major evaginations and severe malapposition after biolimus-eluting stent implantation

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Thayssen, Per; Jensen, Lisette Okkels

    2014-01-01

    Peri-stent contrast staining and late acquired malapposition represent pathological vessel wall healing patterns following percutaneous coronary intervention with stent implantation. Earlier studies have described these abnormal vessel wall responses commonly present after implantation of first...... after third-generation biolimus-eluting stent implantation....

  14. Sapphire tube pressure vessel

    Science.gov (United States)

    Outwater, John O.

    2000-01-01

    A pressure vessel is provided for observing corrosive fluids at high temperatures and pressures. A transparent Teflon bag contains the corrosive fluid and provides an inert barrier. The Teflon bag is placed within a sapphire tube, which forms a pressure boundary. The tube is received within a pipe including a viewing window. The combination of the Teflon bag, sapphire tube and pipe provides a strong and inert pressure vessel. In an alternative embodiment, tie rods connect together compression fittings at opposite ends of the sapphire tube.

  15. Image-based stained glass.

    Science.gov (United States)

    Brooks, Stephen

    2006-01-01

    We present a method of restyling an image so that it approximates the visual appearance of a work of stained glass. To this end, we develop a novel approach which involves image warping, segmentation, querying, and colorization along with texture synthesis. In our method, a given input image is first segmented. Each segment is subsequently transformed to match real segments of stained glass queried from a database of image exemplars. By using real sources of stained glass, our method produces high quality results in this nascent area of nonphotorealistic rendering. The generation of the stained glass requires only modest amounts of user interaction. This interaction is facilitated with a unique region-merging tool.

  16. Reactor vessel

    NARCIS (Netherlands)

    Makkee, M.; Kapteijn, F.; Moulijn, J.A.

    1999-01-01

    A reactor vessel (1) comprises a reactor body (2) through which channels (3) are provided whose surface comprises longitudinal inwardly directed parts (4) and is provided with a catalyst (6), as well as buffer bodies (8, 12) connected to the channels (3) on both sides of the reactor body (2) and

  17. Containment vessel

    International Nuclear Information System (INIS)

    Zbirohowski-Koscia, K.F.; Roberts, A.C.

    1980-01-01

    A concrete containment vessel for nuclear reactors is disclosed that is spherical and that has prestressing tendons disposed in first, second and third sets, the tendons of each set being all substantially concentric and centred around a respective one of the three orthogonal axes of the sphere; the tendons of the first set being anchored at each end at a first anchor rib running around a circumference of the vessel, the tendons of the second set being anchored at each end at a second anchor rib running around a circumference of the sphere and disposed at 90 0 to the first rib, and the tendons of the third set being anchored some to the first rib and the remainder to the second rib. (author)

  18. Salt stains from evaporating droplets

    NARCIS (Netherlands)

    Shahidzadeh, N.; Schut, M.F.L.; Desarnaud, J.; Prat, M.; Bonn, D.

    2015-01-01

    The study of the behavior of sessile droplets on solid substrates is not only associated with common everyday phenomena, such as the coffee stain effect, limescale deposits on our bathroom walls, but also very important in many applications such as purification of pharmaceuticals, deicing of

  19. Metabolic markers in relation to hypoxia; staining patterns and colocalization of pimonidazole, HIF-1α, CAIX, LDH-5, GLUT-1, MCT1 and MCT4

    International Nuclear Information System (INIS)

    Rademakers, Saskia E; Lok, Jasper; Kogel, Albert J van der; Bussink, Johan; Kaanders, Johannes HAM

    2011-01-01

    The cellular response of malignant tumors to hypoxia is diverse. Several important endogenous metabolic markers are upregulated under hypoxic conditions. We examined the staining patterns and co-expression of HIF-1α, CAIX, LDH-5, GLUT-1, MCT1 and MCT4 with the exogenous hypoxic cell marker pimonidazole and the association of marker expression with clinicopathological characteristics. 20 biopsies of advanced head and neck carcinomas were immunohistochemically stained and analyzed. All patients were given the hypoxia marker pimonidazole intravenously 2 h prior to biopsy taking. The tumor area positive for each marker, the colocalization of the different markers and the distribution of the markers in relation to the blood vessels were assessed by semiautomatic quantitative analysis. MCT1 staining was present in hypoxic (pimonidazole stained) as well as non-hypoxic areas in almost equal amounts. MCT1 expression showed a significant overall correlation (r = 0.75, p < 0.001) and strong spatial relationship with CAIX. LDH-5 showed the strongest correlation with pimonidazole (r = 0.66, p = 0.002). MCT4 and GLUT-1 demonstrated a typical diffusion-limited hypoxic pattern and showed a high degree of colocalization. Both MCT4 and CAIX showed a higher expression in the primary tumor in node positive patients (p = 0.09 both). Colocalization and staining patterns of metabolic and hypoxia-related proteins provides valuable additional information over single protein analyses and can improve the understanding of their functions and environmental influences

  20. Etika Berbusana Mahasiswa Stain Samarinda

    Directory of Open Access Journals (Sweden)

    Ida Suryani Wijaya

    2012-06-01

    Full Text Available Ethics is about behavior of human being, such as which one is right or wrong. The ethics is always affecting the human life. The ethics gives people orientation how he/she do manything every time every day. Islamic ethics consists of the way how someone interact each other; how someone should do or not to do, how to sit, how to walk, how to eat or drink, how to sleep, or how to get dressed. Al-Qur’an uses three terms to define about dressing, they are: libas, tsiyah, and sarahi. Dressing has a function as covering the body, as assessoris, as the way to do Islamic taqwa, and as an identiy. Dressing ethics of the female students of STAIN Samarinda has been regulated by the rector regulation No 19 of the year 2002 about relation and dressing ethics for the students of STAIN Samarinda.

  1. Angiogenesis and blood vessel stability in inflammatory arthritis.

    LENUS (Irish Health Repository)

    Kennedy, Aisling

    2012-02-01

    OBJECTIVE: To assess blood vessel stability in inflammatory synovial tissue (ST) and to examine neural cell adhesion molecule (NCAM), oxidative DNA damage, and hypoxia in vivo. METHODS: Macroscopic vascularity and ST oxygen levels were determined in vivo in patients with inflammatory arthritis who were undergoing arthroscopy. Vessel maturity\\/stability was quantified in matched ST samples by dual immunofluorescence staining for factor VIII (FVIII)\\/alpha-smooth muscle actin (alpha-SMA). NCAM and 8-oxo-7,8-dihydro-2\\'-deoxyguanosine (8-oxodG) were examined by immunohistochemistry. Angiogenesis was assessed in vitro, using human dermal endothelial cells (HDECs) in a Matrigel tube formation assay. RESULTS: A significant number of immature vessels (showing no pericyte recruitment) was observed in tissue from patients with inflammatory arthritis (P < 0.001), in contrast to osteoarthritic and normal tissue, which showed complete recruitment of pericytes. Low in vivo PO(2) levels in the inflamed joint (median [range] 22.8 [3.2-54.1] mm Hg) were inversely related to increased macroscopic vascularity (P < 0.04) and increased microscopic expression of FVIII and alpha-SMA (P < 0.04 and P < 0.03, respectively). A significant proportion of vessels showed focal expression of NCAM and strong nuclear 8-oxodG expression, implicating a loss of EC-pericyte contact and increased DNA damage, levels of which were inversely associated with low in vivo PO(2) (P = 0.04 for each comparison). Circulating cells were completely negative for 8-oxodG. Exposure of HDEC to 3% O(2) (reflecting mean ST in vivo measurements) significantly increased EC tube formation (P < 0.05). CONCLUSION: Our findings indicate the presence of unstable vessels in inflamed joints associated with hypoxia, incomplete EC-pericyte interactions, and increased DNA damage. These changes may further contribute to persistent hypoxia in the inflamed joint to further drive this unstable microenvironment.

  2. Microwave-stimulated staining of plastic embedded bone marrow sections with the Romanowsky-Giemsa stain: improved staining patterns.

    Science.gov (United States)

    Boon, M E; Kok, L P; Moorlag, H E; Gerrits, P O; Suurmeijer, A J

    1987-07-01

    Staining plastic sections with the Romanowsky-Giemsa method is both time-consuming and difficult. This paper reports how the staining time can be reduced to 25 min using microwave irradiation of the staining solution. It is shown that staining results depend on the fixative used, staining temperature, dye concentration and pH of the staining solution as well as on several parameters of the microwave irradiation technique. The staining patterns are improved when compared with those obtained by conventional staining of plastic sections. The colors are more brilliant and greater contrasts are observed. Basophilia, polychromasia, and orthochromasia accompanying red cell maturation are more pronounced. For white cell maturation the initial appearance of specific granules (neutrophil, basophil, and eosinophil) is more evident. Thus, cell classification is easily accomplished using the described technique. It is suggested that microwave-stimulated staining be considered for routine use.

  3. Standardization of the Romanowsky-Giemsa stain: the influence of staining time on the RG-staining pattern.

    Science.gov (United States)

    Schulte, E

    1987-01-01

    In this paper the influence of staining time on the staining pattern of Romanowsky-Giemsa (RG) type stains is investigated. Smears of rabbit bone marrow and of human venous blood were stained with azure B-eosin Y, azure A-eosin Y and with the cationic dyes alone under varying conditions of staining time and dye concentration. The stained smears were investigated by integrating microdensitometry. DNA-polyacrylamide (PAA) model films were stained with azure A-eosin Y, the extinction of the stained model films was determined by spectrophotometry. With increasing staining time the color of the cell nuclei changed from blue to an intense purple, the texture of the nuclear chromatin became more prominent. Prolonged staining resulted in over-staining of the cell nuclei with loss of a distinct chromatin texture. Besides such factors as dye concentration and pH of the staining solution standardization of staining time may be considered necessary for the reproducibility of the RG staining pattern.

  4. Rotating wall vessel system designed for fluorescent imaging

    Science.gov (United States)

    Tayag, Tristan J.; Dimitrijevich, S. Dan; Del Gallego, Lauren C.; Kumar, Pankaj

    2011-03-01

    Fluorescent imaging of cells and tissues cultured within a rotating wall vessel bioreactor offers quantitative assessment of the 3-dimensional aggregation of cells into tissue constructs. We present the design of a rotating wall vessel system optimized for real-time fluorescent analysis. The modulation transfer function of our system is found to be superior to the commercially-available vessel used in previous fluorescence imaging studies. We demonstrate dynamic fluorescent imaging of DAPI-stained porcine pancreatic islets.

  5. Accelerated staining technique using kitchen microwave oven

    Directory of Open Access Journals (Sweden)

    Archana Mukunda

    2015-01-01

    Full Text Available Introduction: Histopathological diagnosis of specimens is greatly dependent on good sample preparation and staining. Both of these processes is governed by diffusion of fluids and dyes in and out of the tissue, which is the key to staining. Diffusion of fluids can be accelerated by the application of heat that reduces the time of staining from hours to the minute. We modified an inexpensive model of kitchen microwave oven for staining. This study is an attempt to compare the reliability of this modified technique against the tested technique of routine staining so as to establish the kitchen microwave oven as a valuable diagnostic tool. Materials and Methods: Sixty different tissue blocks were used to prepare 20 pairs of slides for 4 different stains namely hematoxylin and eosin, Van Gieson′s, 0.1% toluidine blue and periodic acid-Schiff. From each tissue block, two bits of tissues were mounted on two different slides. One slide was stained routinely, and the other stained inside a microwave. A pathologist evaluated the stained slides and the results so obtained were analyzed statistically. Results: Microwave staining considerably cut down the staining time from hours to seconds. Microwave staining showed no loss of cellular and nuclear details, uniform-staining characteristics and was of excellent quality. Interpretation and Conclusion: The cellular details, nuclear details and staining characteristics of microwave stained tissues were better than or equal to the routine stained tissue. The overall quality of microwave-stained sections was found to be better than the routine stained tissue in majority of cases.

  6. Cell wall staining with Trypan blue enables quantitative analysis of morphological changes in yeast cells

    DEFF Research Database (Denmark)

    Liesche, Johannes; Marek, Magdalena; Günther-Pomorski, Thomas

    2015-01-01

    staining with fluorescent dyes is a valuable tool. Furthermore, cell wall staining is used to facilitate sub-cellular localization experiments with fluorescently-labeled proteins and the detection of yeast cells in non-fungal host tissues. Here, we report staining of Saccharomyces cerevisiae cell wall...... with Trypan Blue, which emits strong red fluorescence upon binding to chitin and yeast glucan; thereby, it facilitates cell wall analysis by confocal and super-resolution microscopy. The staining pattern of Trypan Blue was similar to that of the widely used UV-excitable, blue fluorescent cell wall stain...

  7. Vessel Operator System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Operator cards are required for any operator of a charter/party boat and or a commercial vessel (including carrier and processor vessels) issued a vessel permit from...

  8. Microdissection of stained archival tissue.

    Science.gov (United States)

    Gupta, S K; Douglas-Jones, A G; Morgan, J M

    1997-08-01

    In many tissues the preinvasive stage of neoplastic progression can be identified histologically as dysplasia or in situ disease. There is much interest in defining the molecular events associated with the early stages of neoplasia. Retrieval of histologically recognisable preinvasive neoplastic tissue uncontaminated by inflammatory or stromal cells is important for genetic studies using polymerase chain reaction (PCR) assay. A novel method for microdissection is described in which 10 microns sections are dewaxed, stained with haematoxylin and eosin, dried, covered with Sellotape, and the tissue cut out using a scalpel blade under direct visual control. The method is quick, eliminates problems of operator tremor, preserves the architecture of the micro-dissected tissue (for photographic documentation) and requires no special equipment. The presence of Sellotape and adhesive in the reaction mixture has no detrimental effect on the ability to extract DNA or to perform PCR.

  9. Comparison of immunohistochemical and modified Giemsa stains ...

    African Journals Online (AJOL)

    In 2 cases immunostain could not demonstrate the bacteria but they were identified with modified Giemsa stain while in 5 cases the bacteria were identified by immunostain but not with modified Giemsa stain. The sensitivity of modified Giemsa stain was 85% (CI 66.5-98.8) while the specificity was 89% (CI 60.4 – 97.8).

  10. [Diagnostic stain of helminth eggs (author's transl)].

    Science.gov (United States)

    Cerva, L

    1976-12-01

    A description is given of a diagnostic method for the staining of eggs and larvae of intestinal helminth in smears of both fresh and fixed stool samples. The contents of the eggs and larvae stain red, the background various shades of blue. The most contrasting staining was obtained with thin-walled eggs.

  11. Histological stain evaluation for machine learning applications

    Directory of Open Access Journals (Sweden)

    Jimmy C Azar

    2013-01-01

    Full Text Available Aims: A methodology for quantitative comparison of histological stains based on their classification and clustering performance, which may facilitate the choice of histological stains for automatic pattern and image analysis. Background: Machine learning and image analysis are becoming increasingly important in pathology applications for automatic analysis of histological tissue samples. Pathologists rely on multiple, contrasting stains to analyze tissue samples, but histological stains are developed for visual analysis and are not always ideal for automatic analysis. Materials and Methods: Thirteen different histological stains were used to stain adjacent prostate tissue sections from radical prostatectomies. We evaluate the stains for both supervised and unsupervised classification of stain/tissue combinations. For supervised classification we measure the error rate of nonlinear support vector machines, and for unsupervised classification we use the Rand index and the F-measure to assess the clustering results of a Gaussian mixture model based on expectation-maximization. Finally, we investigate class separability measures based on scatter criteria. Results: A methodology for quantitative evaluation of histological stains in terms of their classification and clustering efficacy that aims at improving segmentation and color decomposition. We demonstrate that for a specific tissue type, certain stains perform consistently better than others according to objective error criteria. Conclusions: The choice of histological stain for automatic analysis must be based on its classification and clustering performance, which are indicators of the performance of automatic segmentation of tissue into morphological components, which in turn may be the basis for diagnosis.

  12. Standardization of Romanowsky stains. The relationship between stain composition and performance.

    Science.gov (United States)

    Marshall, P N; Bentley, S A; Lewis, S M

    1978-03-01

    A panel of 17 eminent haematologists has assessed the performance of 5 Romanowsky stains prepared from pure component dyes, comparing the suitability and acceptability of these stains for the preparation of routine blood and bone-marrow films. It was found that the results obtained using the stain described by Marshall et al (1975) were comparable to those obtained using a modification of the stain described by Wittekind et al (1976). The performance of the 3 other stains was less acceptable. Variations in stain formulation have been correlated with stain performance.

  13. Distribution of Vascular Patterns in Different Subtypes of Renal Cell Carcinoma. A Morphometric Study in Two Distinct Types of Blood Vessels.

    Science.gov (United States)

    Ruiz-Saurí, Amparo; García-Bustos, V; Granero, E; Cuesta, S; Sales, M A; Marcos, V; Llombart-Bosch, A

    2017-07-01

    To analyze the presence of mature and immature vessels as a prognostic factor in patients with renal cell carcinoma and propose a classification of renal cancer tumor blood vessels according to morphometric parameters. Tissue samples were obtained from 121 renal cell carcinoma patients who underwent radical nephrectomy. Staining with CD31 and CD34 was used to differentiate between immature (CD31+) and mature (CD34+) blood vessels. We quantified the microvascular density, microvascular area and different morphometric parameters: maximum diameter, minimum diameter, major axis, minor axis, perimeter, radius ratio and roundness. We found that the microvascular density was higher in CD31+ than CD34+ vessels, but CD34+ vessels were larger than CD31+ vessels, as well as being strongly correlated with the ISUP tumor grade. We also identified four vascular patterns: pseudoacinar, fascicular, reticular and diffuse. Pseudoacinar and fascicular patterns were more frequent in clear cell renal cell carcinoma (37.62 and 35.64% respectively), followed by reticular pattern (21.78%), while in chromophobe tumors the reticular pattern predominated (90%). The isolated pattern was present in all papillary tumors (100%). In healthy renal tissue, the pseudoacinar and isolated patterns were differentially found in the renal cortex and medulla respectively. We defined four distinct vascular patterns significantly related with the ISUP tumor grade in renal cell carcinomas. Further studies in larger series are needed in order to validate these results. Analysis of both mature and immature vessels (CD34+ and CD31+) provides additional information when evaluating microvascular density.

  14. The standard Romanowsky-Giemsa stain in histology.

    Science.gov (United States)

    Wittekind, D; Schulte, E; Schmidt, G; Frank, G

    1991-01-01

    A new and technically simple Romanowsky-Giemsa (RG) stain is proposed as a standardized technique for use in histology. An RG stock solution (pure azure B 7.5 g/l, eosin Y as eosinic acid 1.2 g/l in dimethylsulfoxide) is diluted to form the working solution with HEPES-buffer, pH 6. Staining time is 30-90 min after formol-calcium solution (or 2-4 hr after formaldehyde-organic acid mixtures). The resulting overstained sections are to be differentiated. A tannic acid-acetic acid combination in an isopropanol-water mixture was found to give optimum results within 100 sec. Subsequent dehydration is in isopropanol only. The staining pattern obtained is polychrome. The distribution of colors in detail is influenced by the modes of pre- and posttreatment. Of practical interest is the development of green and greenish blue colors on collagen fibrils which contrast strongly against the pink of sarcoplasm. For this and other reasons, this RG stain version seems suitable to replace the trichrome Gomori-type trichrome stains under appropriate processing conditions.

  15. Indirect immunofluorescence staining of cultured neural cells.

    Science.gov (United States)

    Barbierato, Massimo; Argentini, Carla; Skaper, Stephen D

    2012-01-01

    Immunofluorescence is a technique allowing the visualization of a specific protein or antigen in cells or tissue sections by binding a specific antibody chemically conjugated with a fluorescent dye such as fluorescein isothiocyanate. There are two major types of immunofluorescence staining methods: (1) direct immunofluorescence staining in which the primary antibody is labeled with fluorescence dye and (2) indirect immunofluorescence staining in which a secondary antibody labeled with fluorochrome is used to recognize a primary antibody. This chapter describes procedures for the application of indirect immunofluorescence staining to neural cells in culture.

  16. The clinical impact of mean vessel size and solidity in breast carcinoma patients.

    Directory of Open Access Journals (Sweden)

    Lars Tore Gyland Mikalsen

    Full Text Available Angiogenesis quantification, through vessel counting or area estimation in the most vascular part of the tumour, has been found to be of prognostic value across a range of carcinomas, breast cancer included. We have applied computer image analysis to quantify vascular properties pertaining to size, shape and spatial distributions in photographed fields of CD34 stained sections. Aided by a pilot (98 cases, seven parameters were selected and validated on a separate set from 293 breast cancer patients. Two new prognostic markers were identified through continuous cox regression with endpoints breast cancer specific survival and distant disease free survival: The average size of the vessels as measured by their perimeter (p = 0.003 and 0.004, respectively, and the average complexity of the vessel shapes measured by their solidity (p = 0.004 and 0.004. The Hazard ratios for the corresponding median-dichotomized markers were 2.28 (p = 0.005 and 1.89 (p = 0.016 for the mean perimeter and 1.80 (p = 0.041 and 1.55 (p = 0.095 for the shape complexity. The markers were associated with poor histologic type, high grade, necrosis, HR negativity, inflammation, and p53 expression (vessel size only. Both markers were found to strongly influence the prognostic properties of vascular invasion (VI and disseminated tumour cells in the bone marrow. The latter being prognostic only in cases with large vessels (p = 0.004 and 0.043 or low complexity (p = 0.018 and 0.024, but not in the small or complex vessel groups (p>0.47. VI was significant in all groups, but showed greater hazard ratios for small and low complexity vessels (6.54-11.2 versus large and high complexity vessels (2.64-3.06. We find that not only the overall amount of produced vasculature in angiogenic hot-spots is of prognostic significance, but also the morphological appearance of the generated vessels, i.e. the size and shape of vessels in the studied hot spots.

  17. Specific Accumulation of Tumor-Derived Adhesion Factor in Tumor Blood Vessels and in Capillary Tube-Like Structures of Cultured Vascular Endothelial Cells

    Science.gov (United States)

    Akaogi, Kotaro; Okabe, Yukie; Sato, Junji; Nagashima, Yoji; Yasumitsu, Hidetaro; Sugahara, Kazuyuki; Miyazaki, Kaoru

    1996-08-01

    Tumor-derived adhesion factor (TAF) was previously identified as a cell adhesion molecule secreted by human bladder carcinoma cell line EJ-1. To elucidate the physiological function of TAF, we examined its distribution in human normal and tumor tissues. Immunochemical staining with an anti-TAF monoclonal antibody showed that TAF was specifically accumulated in small blood vessels and capillaries within and adjacent to tumor nests, but not in those in normal tissues. Tumor blood vessel-specific staining of TAF was observed in various human cancers, such as esophagus, brain, lung, and stomach cancers. Double immunofluorescent staining showed apparent colocalization of TAF and type IV collagen in the vascular basement membrane. In vitro experiments demonstrated that TAF preferentially bound to type IV collagen among various extracellular matrix components tested. In cell culture experiments, TAF promoted adhesion of human umbilical vein endothelial cells to type IV collagen substrate and induced their morphological change. Furthermore, when the endothelial cells were induced to form capillary tube-like structures by type I collagen, TAF and type IV collagen were exclusively detected on the tubular structures. The capillary tube formation in vitro was prevented by heparin, which inhibited the binding of TAF to the endothelial cells. These results strongly suggest that TAF contributes to the organization of new capillary vessels in tumor tissues by modulating the interaction of endothelial cells with type IV collagen.

  18. Chemical contrast observed in thermal images of blood-stained fabrics exposed to steam.

    Science.gov (United States)

    O'Brien, Wayne L; Boltin, Nicholas D; Lu, Zhenyu; Cassidy, Brianna M; Belliveau, Raymond G; Straub, Emory J; DeJong, Stephanie A; Morgan, Stephen L; Myrick, M L

    2015-09-21

    Thermal imaging is not ordinarily a good way to visualize chemical contrast. In recent work, however, we observed strong and reproducible images with chemical contrasts on blood-stained fabrics, especially on more hydrophobic fabrics like acrylic and polyester.

  19. Improvement to reactor vessel

    International Nuclear Information System (INIS)

    1974-01-01

    The vessel described includes a prestressed concrete vessel containing a chamber and a removable cover closing this chamber. The cover is in concrete and is kept in its closed position by main and auxiliary retainers, comprising fittings integral with the concrete of the vessel. The auxiliary retainers pass through the concrete of the cover. This improvement may be applied to BWR, PWR and LMFBR type reactor vessel [fr

  20. Standard specimens for stain calibration: application to Romanowsky-Giemsa staining.

    Science.gov (United States)

    Turner, J N; Weir, B; Collins, D N

    1990-01-01

    Standardized specimens with reproducible staining properties were fabricated from extracts of biological objects (bovine liver, nucleoprotamine and defatted muscle). The standard specimens were stained with two formulations of the Romanowsky-Giemsa stain (RG), using the same azure B and eosin Y. One formulation used methanol and Sorensen's buffer and the other DMSO and Hepes buffer as solvents. The standard specimens were stained either in the composite stain or in the individual dyes dissolved in the same solvents and at the same concentration as the composite stain. Solution spectroscopy demonstrated different spectra for the two formulations with some wavelength regions varying by more than an order of magnitude. The RG spectra were also very different from those of the individual dyes dissolved at the RG concentration in the respective solvents. The stained standard specimens were analyzed by microspectrophotometry and were found to have spectra similar to those of cell smears. Furthermore, the standard specimens were shown to be a repeatable substrate for stain uptake. The transmitted light intensity from random fields of the same standardized specimen varied +/- 5%. When specimens were stained at the same time, the specimen-to-specimen variation depended on preparation conditions and the measurement wavelength, but was as good as +/- 5% for some conditions. The quantitative stain performance of both formulations was studied and compared. The standardized specimens provide a tool for the quantitative study of staining processes and specimen preparation procedures and for stain calibration.

  1. ALICE HMPID Radiator Vessel

    CERN Multimedia

    2003-01-01

    View of the radiator vessels of the ALICE/HMPID mounted on the support frame. Each HMPID module is equipped with 3 indipendent radiator vessels made out of neoceram and fused silica (quartz) windows glued together. The spacers inside the vessel are needed to stand the hydrostatic pressure. http://alice-hmpid.web.cern.ch/alice-hmpid

  2. Multicenter Assessment of Gram Stain Error Rates.

    Science.gov (United States)

    Samuel, Linoj P; Balada-Llasat, Joan-Miquel; Harrington, Amanda; Cavagnolo, Robert

    2016-06-01

    Gram stains remain the cornerstone of diagnostic testing in the microbiology laboratory for the guidance of empirical treatment prior to availability of culture results. Incorrectly interpreted Gram stains may adversely impact patient care, and yet there are no comprehensive studies that have evaluated the reliability of the technique and there are no established standards for performance. In this study, clinical microbiology laboratories at four major tertiary medical care centers evaluated Gram stain error rates across all nonblood specimen types by using standardized criteria. The study focused on several factors that primarily contribute to errors in the process, including poor specimen quality, smear preparation, and interpretation of the smears. The number of specimens during the evaluation period ranged from 976 to 1,864 specimens per site, and there were a total of 6,115 specimens. Gram stain results were discrepant from culture for 5% of all specimens. Fifty-eight percent of discrepant results were specimens with no organisms reported on Gram stain but significant growth on culture, while 42% of discrepant results had reported organisms on Gram stain that were not recovered in culture. Upon review of available slides, 24% (63/263) of discrepant results were due to reader error, which varied significantly based on site (9% to 45%). The Gram stain error rate also varied between sites, ranging from 0.4% to 2.7%. The data demonstrate a significant variability between laboratories in Gram stain performance and affirm the need for ongoing quality assessment by laboratories. Standardized monitoring of Gram stains is an essential quality control tool for laboratories and is necessary for the establishment of a quality benchmark across laboratories. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  3. Purified azure B as a reticulocyte stain.

    Science.gov (United States)

    Marshall, P N; Bentley, S A; Lewis, S M

    1976-01-01

    A comparison has been made between reticulocyte preparations stained with purified azure B and with several commerically available batches of brilliant cresyl blue and new methylene blue. Marked variations were observed in the composition and staining performances of the various batches of the two commerically available dyes. Although there were no significant differences in reticulocyte counts obtained with these two dyes, varying amounts of an extraneous, particulate dye deposit were present in these preparations, making accuracte counting both tedious and timeconsuming. Purified azure B, on the other hand, gave reproducibly stained, deposit-free preparations. Reticulocyte counts obtained from azure B preparations correlated almost exactly with those determined using new methylene blue. Purified azure B is therefore recommended as a convenient reticulocyte stain for routine use. Images PMID:64475

  4. Research on pre-staining gel electrophoresis

    International Nuclear Information System (INIS)

    Zhong Ruibo; Liu Yushuang; Zhang Ping; Liu Jingran; Zhao Guofen; Zhang Feng

    2014-01-01

    Background: Gel electrophoresis is a powerful biochemical separation technique. Most biological molecules are completely transparent in the visible region of light, so it is necessary to use staining to show the results after gel electrophoresis, and the general steps of conventional staining methods are time-consuming. Purpose: We try to develop a novel approach to simplify the gel electrophoresis: Pre-Staining Gel Electrophoresis (PSGE), which can make the gel electrophoresis results monitored in real time. Methods: Pre-stain the protein samples with Coomassie Brilliant Blue (CBB) for 30 min before loading the sample into the gel well. Results and Conclusion: PSGE can be successfully used to analyze the binding efficiency of Bovine Serum Albumin (BSA) and amphiphilic polymer via chemical coupling and physical absorption, and the double PSGE also shows a great potential in bio-analytical chemistry. (authors)

  5. New Grocott Stain without Using Chromic Acid

    International Nuclear Information System (INIS)

    Shiogama, Kazuya; Kitazawa, Kayo; Mizutani, Yasuyoshi; Onouchi, Takanori; Inada, Ken-ichi; Tsutsumi, Yutaka

    2015-01-01

    We established a new “ecological” Grocott stain for demonstrating fungi, based upon a 4R principle of refusal, reduction, reuse, and recycle of waste management. Conventional Grocott stain employs environmentally harsh 5% chromic acid for oxidization. Initially, we succeeded in reducing the concentration of chromic acid from 5% to 1% by incubating the solution at 60°C and using five-fold diluted chromic acid solution at which point it was reusable. Eventually, we reached the refusal level where 1% periodic acid oxidization was efficient enough, when combined with preheating of sections in the electric jar, microwave oven, or pressure pan. For convenience sake, we recommend pressure pan heating in tap water for 10 min. Stainability of fungi in candidiasis and aspergillosis was comparable with conventional Grocott stain, while Mucor hyphae showed enhanced staining. The modified sequence was further applicable to detecting a variety of mycotic pathogens in paraffin sections. Our environmentally-friendly Grocott stain also has the advantage of avoiding risk of human exposure to hexavalent chromium solution in the histopathology laboratory. The simple stain sequence is can be easily applied worldwide

  6. Stain Removal Assessment of Two Manual Toothbrushes with an Interproximal Tooth Stain Index.

    Science.gov (United States)

    Farrell, Svetlana; Grender, Julie M; Terézhalmy, Geza; Archila, Luis R

    2015-01-01

    To assess a newly developed index to measure interproximal stain and evaluate the stain removal efficacy of two commercially available manual toothbrushes. This was a randomized, examiner-blind, parallel-group, two-treatment clinical trial of two weeks' duration. Subjects qualified for the study if they had an average Modified Lobene Stain Index of ≥ 1.5 from two anterior teeth. At baseline, subjects brushed in front of a mirror for one minute under supervision. All subjects were provided with a standard 0.243% sodium fluoride dentifrice and were randomly assigned either an Oral-B Pulsar manual brush (OBP) or a Colgate Whitening manual brush (CW) to use for two weeks. Stain was reassessed after two weeks of product use. Stain measurements were conducted using the Modified Lobene Stain Index and the new Interproximal Modified Lobene Stain Index, which allows for assessment of stain in hard-to-reach areas using the same area and intensity scales as the Modified Lobene Stain Index. Use of the two manual brushes resulted in statistically significant reductions in surface stain relative to baseline after two weeks of use. Median stain reductions were 78% and 60% for the OBP and CW, respectively, as measured by the Modified Lobene Stain Index. The mean changes in the composite scores from baseline to week two were 1.85 and 1.57 for the two treatment groups, respectively. Statistically significant reductions from baseline were also found for the intensity and extent of stain measures (p brush and 83% reduction with the CW brush. For the gingival sites, the median stain removal percentages were 83% and 50%, respectively For the body region, a median stain removal of 100% was found for both treatment groups. No statistically significant differences were found between the two groups for the mean composite scores for either index. Both manual brushes showed effective stain removal, including interproximal hard-to-reach sites. The Interproximal Modified Lobene Stain Index

  7. Can Recent Theory of New Lymph Vessel Formation Called ...

    African Journals Online (AJOL)

    ... in lymph vessel staining techniques, it is hypothesized that the formation of new lymph channels, called lymphangiogenesis, sufficiently explains the peculiar relationship between stomach primaries and ovarian (Krukenberg) secondaries. Furthermore, this conclusion can be tested (a) by strictly avoiding the old fashioned ...

  8. Pressure vessel design manual

    CERN Document Server

    Moss, Dennis R

    2013-01-01

    Pressure vessels are closed containers designed to hold gases or liquids at a pressure substantially different from the ambient pressure. They have a variety of applications in industry, including in oil refineries, nuclear reactors, vehicle airbrake reservoirs, and more. The pressure differential with such vessels is dangerous, and due to the risk of accident and fatality around their use, the design, manufacture, operation and inspection of pressure vessels is regulated by engineering authorities and guided by legal codes and standards. Pressure Vessel Design Manual is a solutions-focused guide to the many problems and technical challenges involved in the design of pressure vessels to match stringent standards and codes. It brings together otherwise scattered information and explanations into one easy-to-use resource to minimize research and take readers from problem to solution in the most direct manner possible. * Covers almost all problems that a working pressure vessel designer can expect to face, with ...

  9. Small Vessel Security Strategy

    National Research Council Canada - National Science Library

    2008-01-01

    ...), narcotics, aliens, and other contraband, and other criminals. Small vessels have also been successfully employed overseas by terrorists to deliver Waterborne Improvised Explosive Devices (WBIEDs...

  10. Maury Journals - German Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — German vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  11. Nuclear reactor pressure vessel

    International Nuclear Information System (INIS)

    McDonald, B.N.

    1976-01-01

    In nuclear power reactor systems which have a reactor core inside a pressure vessel, the feedwater inlet pipe and steam discharge nozzle usually require separate pressure vessel penetrations. This requirement involves a great deal of expensive high quality special machining, welding and weld joint testing. The invention overcomes most of these problems by nestling the feedwater inlet pipe inside the steam discharge nozzle. At the same time the individual heat exchanger modules are supported from the pressure vessel at the same location as the nested feedwater inlet pipe and steam discharge nozzle combination, thus eliminating the need to accomodate troublesome differential thermal expansion problems through special structures within the pressure vessel

  12. Potential Value of YAP Staining in Rhabdomyosarcoma.

    Science.gov (United States)

    Ahmed, Atif A; Habeebu, Sultan S; Sherman, Ashley K; Ye, Shui Q; Wood, Nicole; Chastain, Katherine M; Tsokos, Maria G

    2018-03-01

    Rhabdomyosarcoma (RMS) is a common malignancy of soft tissue, subclassified as alveolar (ARMS), pleomorphic (PRMS), spindle cell/sclerosing (SRMS), and embryonal (ERMS) types. The Yes-associated protein (YAP) is a member of the Hippo pathway and a transcriptional regulator that controls cell proliferation. We have studied the immunohistochemical expression of YAP in different RMSs, arranged in tissue microarray (TMA) and whole slide formats. Pertinent clinical data including patient age, gender, tumor location, and clinical stage were collected. Out of 96 TMA cases, 30 cases (31%) were pleomorphic, 27 (28%) were embryonal, 24 (25%) alveolar, and 15 (16%) spindle cell. Positive nuclear YAP staining was seen in the PRMS (17/30, 56.7%), SRMS (7/15, 46.7%), ERMS (19/27 or 70%), and less in ARMS (37.5%). YAP nuclear staining was significantly more prevalent in ERMS than ARMS ( p=0.02). Of the 41 whole slide cases, nuclear staining was detected in all ARMS but was restricted in distribution to 30% staining. These results highlight the role of YAP in RMS tumorigenesis, a fact that can be useful in engineering targeted therapy. Restricted nuclear YAP staining (<30% of cells) may be of value in the diagnosis of ARMS.

  13. Staining of proteins in gels with Coomassie G-250 without organic solvent and acetic acid.

    Science.gov (United States)

    Lawrence, Ann-Marie; Besir, H Uuml Seyin

    2009-08-14

    In classical protein staining protocols using Coomassie Brilliant Blue (CBB), solutions with high contents of toxic and flammable organic solvents (Methanol, Ethanol or 2-Propanol) and acetic acid are used for fixation, staining and destaining of proteins in a gel after SDS-PAGE. To speed up the procedure, heating the staining solution in the microwave oven for a short time is frequently used. This usually results in evaporation of toxic or hazardous Methanol, Ethanol or 2-Propanol and a strong smell of acetic acid in the lab which should be avoided due to safety considerations. In a protocol originally published in two patent applications by E.M. Wondrak (US2001046709 (A1), US6319720 (B1)), an alternative composition of the staining solution is described in which no organic solvent or acid is used. The CBB is dissolved in bidistilled water (60-80 mg of CBB G-250 per liter) and 35 mM HCl is added as the only other compound in the staining solution. The CBB staining of the gel is done after SDS-PAGE and thorough washing of the gel in bidistilled water. By heating the gel during the washing and staining steps, the process can be finished faster and no toxic or hazardous compounds are evaporating. The staining of proteins occurs already within 1 minute after heating the gel in staining solution and is fully developed after 15-30 min with a slightly blue background that is destained completely by prolonged washing of the stained gel in bidistilled water, without affecting the stained protein bands.

  14. Adversarial Stain Transfer for Histopathology Image Analysis.

    Science.gov (United States)

    Bentaieb, Aicha; Hamarneh, Ghassan

    2018-03-01

    It is generally recognized that color information is central to the automatic and visual analysis of histopathology tissue slides. In practice, pathologists rely on color, which reflects the presence of specific tissue components, to establish a diagnosis. Similarly, automatic histopathology image analysis algorithms rely on color or intensity measures to extract tissue features. With the increasing access to digitized histopathology images, color variation and its implications have become a critical issue. These variations are the result of not only a variety of factors involved in the preparation of tissue slides but also in the digitization process itself. Consequently, different strategies have been proposed to alleviate stain-related tissue inconsistencies in automatic image analysis systems. Such techniques generally rely on collecting color statistics to perform color matching across images. In this work, we propose a different approach for stain normalization that we refer to as stain transfer. We design a discriminative image analysis model equipped with a stain normalization component that transfers stains across datasets. Our model comprises a generative network that learns data set-specific staining properties and image-specific color transformations as well as a task-specific network (e.g., classifier or segmentation network). The model is trained end-to-end using a multi-objective cost function. We evaluate the proposed approach in the context of automatic histopathology image analysis on three data sets and two different analysis tasks: tissue segmentation and classification. The proposed method achieves superior results in terms of accuracy and quality of normalized images compared to various baselines.

  15. Detection Of Concrete Deterioration By Staining

    Science.gov (United States)

    Guthrie, Jr., George D.; Carey, J. William

    1999-09-21

    A method using concentrated aqueous solutions of sodium cobaltinitrite and a rhodamine dye is described which can be used to identify concrete that contains gels formed by the alkali-silica reaction (ASR), and to identify degraded concrete which results in a porous or semi-permeable paste due to carbonation or leaching. These solutions present little health or environmental risk, are readily applied, and rapidly discriminate between two chemically distinct gels; K-rich, Na--K--Ca--Si gels are identified by yellow staining, and alkali-poor, Ca--Si gels are identified by pink staining.

  16. News from the biological stain commission

    DEFF Research Database (Denmark)

    Kiernan, J.A.; Lyon, Hans Oluf

    2008-01-01

    In the three earlier editions of News from the Biological Stain Commission (BSC), under the heading of "Regulatory affairs," the BSC's International Affairs Committee reported on the work of Technical Committee 212, Clinical Laboratory Testing and in Vitro Diagnostic Test Systems of the Internati......In the three earlier editions of News from the Biological Stain Commission (BSC), under the heading of "Regulatory affairs," the BSC's International Affairs Committee reported on the work of Technical Committee 212, Clinical Laboratory Testing and in Vitro Diagnostic Test Systems...

  17. Identification of Cyclospora cayetanensis in stool using different stains.

    Science.gov (United States)

    Negm, A Y

    1998-08-01

    Cyclospora cayetanensis, a newly emerging coccidian protozoa is world-wide in distribution. In the present study, different concentrations and staining techniques were used for identification of Cyclospora. Formol-ether sedimentation and Sheather's sugar flotation were used as concentration techniques and the different stains used were: the modified Ziehl-Neelsen, Giemsa, safranin-methylene blue, modifications of trichrome stain, calcoflour white and finally phenol-auramine. The safranin stain was the best, as it stained all the oocysts of Cyclospora uniformly, besides being rapid and easily applicable in the laboratories. Phenol-auramine stained the oocysts well, where both the wall and internal contents fluoresced brightly. With the calcoflour white stain, only the wall of oocysts took that fluorescent stain. The modified Ziehl-Neelsen stained some of the oocysts well, yet great variability in the staining pattern was noticed. Cyclospora oocysts were not efficiently stained with either trichrome modifications or Giemsa stains.

  18. PRESSURE-RESISTANT VESSEL

    NARCIS (Netherlands)

    Beukers, A.; De Jong, T.

    1997-01-01

    Abstract of WO 9717570 (A1) The invention is directed to a wheel-shaped pressure-resistant vessel for gaseous, liquid or liquefied material having a substantially rigid shape, said vessel comprising a substantially continuous shell of a fiber-reinforced resin having a central opening, an inner

  19. Containment vessel drain system

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  20. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    This invention relates to an apparatus and method for sealing the cold leg nozzles of a nuclear reactor pressure vessel from a remote location during maintenance and inspection of associated steam generators and pumps while the pressure vessel and refueling canal are filled with water. The apparatus includes a sealing plug for mechanically sealing the cold leg nozzle from the inside of a reactor pressure vessel. The sealing plugs include a primary and a secondary O-ring. An installation tool is suspended within the reactor vessel and carries the sealing plug. The tool telescopes to insert the sealing plug within the cold leg nozzle, and to subsequently remove the plug. Hydraulic means are used to activate the sealing plug, and support means serve to suspend the installation tool within the reactor vessel during installation and removal of the sealing plug

  1. Photoacoustic imaging of port-wine stains

    NARCIS (Netherlands)

    Kolkman, Roy G. M.; Mulder, Miranda J.; Glade, Conrad P.; Steenbergen, Wiendelt; van Leeuwen, Ton G.

    2008-01-01

    BACKGROUND AND OBJECTIVE: To optimize laser therapy of port-wine stains (PWSs), information about the vasculature as well as lesion depth is valuable. In this study we investigated the use of photoacoustic imaging (PAI) to obtain this information. STUDY DESIGN/MATERIALS AND METHODS: PAI uses pulsed

  2. Photoacoustic Imaging of Port-Wine Stains

    NARCIS (Netherlands)

    Kolkman, R.G.M.; Mulder, M.J.; Mulder, Miranda J.; Glade, Conrad P.; Steenbergen, Wiendelt; van Leeuwen, Ton

    2008-01-01

    Background and Objective: To optimize laser therapy of port-wine stains (PWSs), information about the vasculature as well as lesion depth is valuable. In this study we investigated the use of photoacoustic imaging (PAI) to obtain this information. - Study Design/Materials and Methods: PAI uses

  3. A comparative assessment of commonly employed staining ...

    African Journals Online (AJOL)

    Following an increase in the number of reports of Cryptosporidium infections and the problems encountered in detecting these organisms in faecal smears, a comparative assessment of a modification of the Sheather's flotation technique and other commonly employed staining procedures proved the modified Sheather's ...

  4. A comparative assessment of commonly employed staining ...

    African Journals Online (AJOL)

    1991-03-16

    Mar 16, 1991 ... methylene blue;8 fluorescence (auramine-phenoI9 and direct immunofluorescence1o. • ll. ); negative staining (periodic acid-. Schiff12. ); and flotation (Sheather's ..... using a direct immunofluorescence assay. Pediatr Infect Dis 1986; 5: 139-142. 12. Horen WP. Detection of Cryptosporidium in human faecal ...

  5. The Language of Stained-Glass Windows

    Science.gov (United States)

    Brew, Charl Anne

    2010-01-01

    The splendor and beauty of stained glass punctuates any room. In this article, the author describes a cross-curriculum project which incorporated the French classes' research and written study of France in the Middle Ages. For the project the author suggested Sainte-Chapelle which is considered a reliquary and was built by Louis IX to house the…

  6. Corneal staining after treatment with topical tetracycline

    NARCIS (Netherlands)

    Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Slomovic, Allan R.; Spanjaard, Lodewijk

    2006-01-01

    PURPOSE: The purpose of this paper is to report a case of corneal staining after treatment with topical tetracycline. METHODS: A patient with crystalline keratopathy caused by Streptococcus viridans after corneal transplantation was treated topically with tetracycline eye drops, based on results of

  7. Staining of Proteins in Gels with Coomassie G-250 without Organic Solvent and Acetic Acid

    Science.gov (United States)

    Lawrence, Ann-Marie; Besir, Hüseyin

    2009-01-01

    In classical protein staining protocols using Coomassie Brilliant Blue (CBB), solutions with high contents of toxic and flammable organic solvents (Methanol, Ethanol or 2-Propanol) and acetic acid are used for fixation, staining and destaining of proteins in a gel after SDS-PAGE. To speed up the procedure, heating the staining solution in the microwave oven for a short time is frequently used. This usually results in evaporation of toxic or hazardous Methanol, Ethanol or 2-Propanol and a strong smell of acetic acid in the lab which should be avoided due to safety considerations. In a protocol originally published in two patent applications by E.M. Wondrak (US2001046709 (A1), US6319720 (B1)), an alternative composition of the staining solution is described in which no organic solvent or acid is used. The CBB is dissolved in bidistilled water (60-80mg of CBB G-250 per liter) and 35 mM HCl is added as the only other compound in the staining solution. The CBB staning of the gel is done after SDS-PAGE and thorough washing of the gel in bidistilled water. By heating the gel during the washing and staining steps, the process can be finished faster and no toxic or hazardous compunds are evaporating. The staining of proteins occurs already within 1 minute after heating the gel in staining solution and is fully developed after 15-30 min with a slightly blue background that is destained completely by prolonged washing of the stained gel in bidistilled water, without affecting the stained protein bands. PMID:19684570

  8. Cheboygan Vessel Base

    Data.gov (United States)

    Federal Laboratory Consortium — Cheboygan Vessel Base (CVB), located in Cheboygan, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). CVB was established by congressional...

  9. Coastal Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch (landed catch) and effort for fishing trips made by vessels that have been issued a Federal permit for the Gulf of Mexico reef fish,...

  10. Vessel Sewage Discharges

    Science.gov (United States)

    Vessel sewage discharges are regulated under Section 312 of the Clean Water Act, which is jointly implemented by the EPA and Coast Guard. This homepage links to information on marine sanitation devices and no discharge zones.

  11. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  12. 2013 Fishing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  13. Reactor pressure vessel support

    International Nuclear Information System (INIS)

    Butti, J.P.

    1978-01-01

    A link and pin support system provides the primary vertical and lateral support for a nuclear reactor pressure vessel without restricting thermally induced radial and vertical expansion and contraction

  14. 2013 Cargo Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  15. Maury Journals - US Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — U.S. vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  16. 2013 Tanker Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  17. 2013 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  18. Ocean Station Vessel

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean Station Vessels (OSV) or Weather Ships captured atmospheric conditions while being stationed continuously in a single location. While While most of the...

  19. 2011 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  20. 2011 Fishing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  1. 2011 Cargo Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  2. Pressurized Vessel Slurry Pumping

    International Nuclear Information System (INIS)

    Pound, C.R.

    2001-01-01

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air

  3. 2013 Passenger Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  4. 21 CFR 864.1850 - Dye and chemical solution stains.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dye and chemical solution stains. 864.1850 Section... (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1850 Dye and chemical solution stains. (a) Identification. Dye and chemical solution stains for medical purposes are mixtures of...

  5. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  6. Laser Treatment of Port Wine Stains

    Science.gov (United States)

    Majaron, Boris; Nelson, J. Stuart

    Port wine stain (PWS), also called nevus flammeus, is a congenital, cutaneous vascular malformation involving post-capillary venules which produce a light pink to red to dark-red-violet discoloration of human skin [1]. PWS occurs in an estimated 3 children per 1000 live births, affecting males and females and all racial groups equally [2]. There appears to be no hereditary predilection for PWS within families. There are no known risk factors or ways to prevent PWS.

  7. Diagnosis of Blastocystis hominis by different staining techniques.

    Science.gov (United States)

    Khalifa, A M

    1999-01-01

    One hundred and fifty stool samples were collected from diarrheic patients of different ages, and examined for Blastocystis hominis by direct smears and concentrated by Sheather's sugar flotation. Staining was done by: Giemsa, two modifications of trichrome stain, modified Ziehl-Neelsen, safranin-methylene blue and two-auramine stains. Out of the 150 cases nine were positive for blastocystosis. The best stains were safranin-methylene blue and modified Ziehl-Neelsen stains. They had the advantage of staining cysts and amoeboid forms besides being rapid and easy to perform. The modified trichrome stains identified 8 ie, less specific and were time consuming. The auramine dyes stained the cyst, both the wall and internal body fluoresced brightly. Giemsa stain was not an efficient stain. Scanning and transmission electron microscopy (SEM, TEM) were performed to study the fine ultrastructure.

  8. FFTF and CRBRP reactor vessels

    International Nuclear Information System (INIS)

    Morgan, R.E.

    1977-01-01

    The Fast Flux Test Facility (FFTF) reactor vessel and the Clinch River Breeder Reactor Plant (CRBRP) reactor vessel each serve to enclose a fast spectrum reactor core, contain the sodium coolant, and provide support and positioning for the closure head and internal structure. Each vessel is located in its reactor cavity and is protected by a guard vessel which would ensure continued decay heat removal capability should a major system leak develop. Although the two plants have significantly different thermal power ratings, 400 megawatts for FFTF and 975 megawatts for CRBRP, the two reactor vessels are comparable in size, the CRBRP vessel being approximately 28% longer than the FFTF vessel. The FFTF vessel diameter was controlled by the space required for the three individual In-Vessel Handling Machines and Instrument Trees. Utilization of the triple rotating plug scheme for CRBRP refueling enables packaging of the larger CRBRP core in a vessel the same diameter as the FFTF vessel

  9. Microspectrophotometric studies of Romanowsky stained blood cells. II. Comparison of the performance of two standardized stains.

    Science.gov (United States)

    Marshall, P N; Galbraith, W; Navarro, E F; Bacus, J W

    1981-11-01

    This paper describes a comparison of the performance of two standardized Romanowsky blood stains, namely those of Marshall et al. and Wittekind et al., both containing azure B and eosin alone. Stain performance is assessed objectively by the use of three complementary techniques, all based on the visible absorbance spectra of stained cellular substrates. The first of these techniques is a simple comparison of the shapes and heights of the absorbance spectra. The second technique uses the CIE Colorimetric System, and thus permits the quantitation of colour in a manner that agrees with human observation. CIE co-ordinates (chromaticity points, luminance) are calculated directly from absorbance spectra. The third technique is that of spectral subtraction, which yields a set of factors which describe the quantities of component dyes which are bound by the object. This technique, unlike the other two, requires a priori knowledge of the dyes used in the stains, and their spectra when bound to cellular substrates. Although the differences between the two methods are subtle, and hard for the subjective observer to define, the objective methods described here do show statistically significant differences. Wittekind's stain produces less intense staining, except for lymphocyte and monocyte cytoplasms. To the human eye, the differential coloration of these two substrates is more pronounced, but the difference between all nuclei and cytoplasm is less marked. The major difference in the uptake of dye components is in the small quantities of eosin dimer that are bound in this technique.

  10. Comparison of methylene blue/gentian violet stain to Gram's stain for the rapid diagnosis of gonococcal urethritis in men.

    Science.gov (United States)

    Taylor, Stephanie N; DiCarlo, Richard P; Martin, David H

    2011-11-01

    We compared a simple, one-step staining procedure using a mixture of methylene blue and gentian violet to Gram stain for the detection of gonococcal urethritis. The sensitivity and specificity of both Gram stain and methylene blue/gentian violet stain were 97.3% and 99.6%, respectively. There was a 100% correlation between the 2 methods.

  11. Pressure vessel, in particular reactor pressure vessel

    International Nuclear Information System (INIS)

    1976-01-01

    The task to design the pre-stressing facility for a pressure vessel, especially for nuclear reactors, wiht pre-stressed jacket and pre-stressing facility, the latter one showing circumferential steel tendons supported polygonally on the outer side of the jacket by means of supporting shoes, in such a way that simply defined tensions can be generated and re-tensioning of the tendons can be carried out easily is solved according to the invention by keeping the circumference of the steel tendons fixed and by designing the supporting shoes as stressing shoes. The defined tensions are applied through the stressing shoes. (ORU) [de

  12. Quantitative comparison of immunohistochemical staining measured by digital image analysis versus pathologist visual scoring

    Directory of Open Access Journals (Sweden)

    Rizzardi Anthony E

    2012-06-01

    Full Text Available Abstract Immunohistochemical (IHC assays performed on formalin-fixed paraffin-embedded (FFPE tissue sections traditionally have been semi-quantified by pathologist visual scoring of staining. IHC is useful for validating biomarkers discovered through genomics methods as large clinical repositories of FFPE specimens support the construction of tissue microarrays (TMAs for high throughput studies. Due to the ubiquitous availability of IHC techniques in clinical laboratories, validated IHC biomarkers may be translated readily into clinical use. However, the method of pathologist semi-quantification is costly, inherently subjective, and produces ordinal rather than continuous variable data. Computer-aided analysis of digitized whole slide images may overcome these limitations. Using TMAs representing 215 ovarian serous carcinoma specimens stained for S100A1, we assessed the degree to which data obtained using computer-aided methods correlated with data obtained by pathologist visual scoring. To evaluate computer-aided image classification, IHC staining within pathologist annotated and software-classified areas of carcinoma were compared for each case. Two metrics for IHC staining were used: the percentage of carcinoma with S100A1 staining (%Pos, and the product of the staining intensity (optical density [OD] of staining multiplied by the percentage of carcinoma with S100A1 staining (OD*%Pos. A comparison of the IHC staining data obtained from manual annotations and software-derived annotations showed strong agreement, indicating that software efficiently classifies carcinomatous areas within IHC slide images. Comparisons of IHC intensity data derived using pixel analysis software versus pathologist visual scoring demonstrated high Spearman correlations of 0.88 for %Pos (p  Virtual slides The virtual slide(s for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1649068103671302

  13. [Detection and documentation of masked blood stains with infrared technique].

    Science.gov (United States)

    Du Chesne, A; Bajanowski, T; Brinkmann, B

    1993-01-01

    On dark textiles the visualization of blood stains with the naked eye is either difficult or impossible. In experimental stains and in case work stains we have applied an infrared (IR) video camera in combination with a video printer. As an alternative, an IR goggle was used which could also be connected with a video printer. The results obtained on a variety of different stains and stain carriers are encouraging. Stains showing poor contrast usually become more contrasted. Stains which are partly masked can become complete. Masked stains can become visible. The system is not effective in all combinations of stains and carriers. But it solves a great proportion of formerly problematic cases. Documentation of results is quite easy if a videoprinter is used.

  14. Fetal Outcome in Meconium Stained Deliveries

    Science.gov (United States)

    Mundhra, Rajlaxmi; Agarwal, Manika

    2013-01-01

    Objective: To evaluate the foetal outcome in Meconium Stained Amniotic Fluid (MSAF). Material and Methods: This prospective observational study was carried out in the Department of Obstetrics and Gynaecology, North Eastern Indira Gandhi Regional Institute of Health And Medical Sciences, Shillong, India, over a period of eighteen months, from January 2010 to June 2011. A total of 355 pregnant women who had completed more than 37 weeks of gestation, with singleton pregnancies and cephalic presentations were included in this study. One hundred and sixty five cases with MSAF, were thus selected and they were compared with 190 randomly selected controls. Results: Among 165 cases, 27.88 % of the cases had regular visits to the Institute at least 3 times previously, 72.12% cases had no previous visit at all. Primigravidas accounted for a majority of cases and approximately 50% cases had gestational ages of more than 40 weeks Pregnancies complicated with pregnancy induced hypertension had statistically significant higher rates of meconium staining among cases (16.97%), as compared to those among controls (7.89%). 21.81% cases had foetal heart rate abnormalities, as were detected by electronic foetal monitoring and presence of foetal bradycardia was statistically higher in cases compared to that in controls. Casearean section rates were nearly double in cases (49.09%). Neonatal outcome was poor in terms of low Apgar score at birth, birth asphyxia, Meconium Aspiration Syndrome (MAS) and increased neonatal admission among cases as compared to that among controls. Conclusion: Meconium stained amniotic fluid is really worrisome from both, obstetrician’s and paediatrician’s points of view, as it increases the caesarean rates, causes birth asphyxia, MAS and increases neonatal intensive care unit admissions. PMID:24551662

  15. Robust fadeout profile of an evaporation stain

    Science.gov (United States)

    Witten, T. A.

    2009-06-01

    We propose an explanation for the commonly seen fading in the density of a stain remaining after a droplet has dried on a surface. The density decreases as a power p of the distance from the edge. For thin, dilute drops of general shape this power is determined by a flow stagnation point in the distant interior of the drop. The power p depends on the local evaporation rate J(0) at the stagnation point and the liquid depth h(0) there: p = 1 - 2~ (h(0)/\\bar h)(\\bar J/J(0)) , where \\bar h and \\bar J are averages over the drop surface.

  16. Romanowsky staining in cytopathology: history, advantages and limitations.

    Science.gov (United States)

    Krafts, K P; Pambuccian, S E

    2011-04-01

    If the entire discipline of diagnostic cytopathology could be distilled into a single theme, it would be the Papanicolaou stain. Yet it was the Romanowsky stain upon which the discipline of cytopathology was founded. Both stains are used today in the cytopathology laboratory, each for a different and complementary purpose. We trace the history of cytopathological stains and discuss the advantages and limitations of Romanowsky-type stains for cytological evaluation. We also provide suggestions for the advantageous use of Romanowsky-type stains in cytopathology.

  17. Reactor pressure vessel materials

    International Nuclear Information System (INIS)

    Suzuki, K.

    1998-01-01

    As a result of the popularity of the Agencies report 'Neutron Irradiation Embrittlement of Reactor Pressure Vessel Steels' of 1975, it was decided that another report on this broad subject would be of use. In this report, background and contemporary views on specially identified areas of the subject are considered as self-contained chapters, written by experts. Chapter 3 offers a detailed treatment of the selection criteria and properties of reactor pressure vessel materials. The main attention is directed towards steel and ingot making and the subsequent material processing

  18. Mast Cell Density in Oral Lesions using Metachromatic Stains: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Shilpa Chirappurath Natesan

    2017-10-01

    Full Text Available Introduction: Mast Cells (MCs are bone marrow derived granular cells, distributed throughout the body near blood vessels, nerves and subepithelial areas. MC granules stain by basic dyes but are most readily demonstrated by metachromatic dyes such as toluidine blue and azure A. Aim: This study focuses on evaluating and comparing the count of MCs by identification and staining of these cells by azure A with toluidine blue as a control, in normal oral mucosa and in various other oral pathologies. Materials and Methods: Five cases each of Normal Oral Mucosa (NOM, Inflammatory Fibrous Hyperplasia (IFH, Oral Pyogenic Granuloma (OPG, Oral Lichen Planus (OLP and Oral Squamous Cell Carcinoma (OSCC were stained with 1% toluidine blue and azure A. Results: Mean MC count was higher in all four lesions when compared to normal oral mucosa with both stains. OLP exhibited the maximum amount of mean MC count when compared to other pathologies under study. With all four lesions, toluidine blue exhibited higher number of MC density (count/high power field compared to azure A. Conclusion: Higher count of MCs was noticed in all four lesions indicating a possible role of MCs in their pathogenesis either directly or indirectly. Also, the number of degranulated MCs was more in OLP followed by OSCC, IFH and OPG.

  19. Differentiation-associated staining with anti-pimonidazole antibodies in head and neck tumors.

    NARCIS (Netherlands)

    Janssen, H.L.K.; Hoebers, F.J.; Sprong, D.; Goethals, L.; Williams, K.J.; Stratford, I.J.; Haustermans, K.; Balm, A.J.M.; Begg, A.C.

    2004-01-01

    BACKGROUND AND PURPOSE: Hypoxia is a strong negative prognostic factor for all three major treatment modalities for cancer. The bioreductive drug pimonidazole is currently under clinical investigation as a hypoxia marker. In human head and neck tumors, in addition to staining patterns typical of

  20. Differentiation-associated staining with anti-pimonidazole antibodies in head and neck tumors

    NARCIS (Netherlands)

    Janssen, Hilde L. K.; Hoebers, Frank J.; Sprong, Debbie; Goethals, Laurence; Williams, Kaye J.; Stratford, Ian J.; Haustermans, Karin M.; Balm, Alfons J.; Begg, Adrian C.

    2004-01-01

    BACKGROUND AND PURPOSE: Hypoxia is a strong negative prognostic factor for all three major treatment modalities for cancer. The bioreductive drug pimonidazole is currently under clinical investigation as a hypoxia marker. In human head and neck tumors, in addition to staining patterns typical of

  1. Cell wall staining with Trypan Blue enables quantitative analysis of morphological changes in yeast cells

    Directory of Open Access Journals (Sweden)

    Johannes eLiesche

    2015-02-01

    Full Text Available Yeast cells are protected by a cell wall that plays an important role in the exchange of substances with the environment. The cell wall structure is dynamic and can adapt to different physiological states or environmental conditions. For the investigation of morphological changes, selective staining with fluorescent dyes is a valuable tool. Furthermore, cell wall staining is used to facilitate sub-cellular localization experiments with fluorescently-labeled proteins and the detection of yeast cells in non-fungal host tissues. Here, we report staining of Saccharomyces cerevisiae cell wall with Trypan Blue, which emits strong red fluorescence upon binding to chitin and yeast glucan; thereby, it facilitates cell wall analysis by confocal and super-resolution microscopy. The staining pattern of Trypan Blue was similar to that of the widely used UV-excitable, blue fluorescent cell wall stain Calcofluor White. Trypan Blue staining facilitated quantification of cell size and cell wall volume when utilizing the optical sectioning capacity of a confocal microscope. This enabled the quantification of morphological changes during growth under anaerobic conditions and in the presence of chemicals, demonstrating the potential of this approach for morphological investigations or screening assays.

  2. Consequences of meconium stained amniotic fluid: what does the evidence tell us?

    Science.gov (United States)

    Hutton, Eileen K; Thorpe, Julia

    2014-07-01

    Meconium stained amniotic fluid (MSAF) is common and associated with meconium aspiration syndrome (MAS). Other consequences of meconium passage before birth are less well understood. We reviewed the literature for original papers reporting on outcomes associated with MSAF. Among preterm infants MSAF is more prevalent than previously believed and is associated with higher neonatal morbidity. Intrauterine exposure to meconium is associated with inflammation of tissues of the lung, chorionic plate and umbilical vessels and through various mechanisms may contribute to neonatal morbidity, independent of MAS. No compelling evidence supported an association between MSAF and increased neurological impairment, including early seizure activity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. The reactor vessel steels

    International Nuclear Information System (INIS)

    Bilous, W.; Hajewska, E.; Szteke, W.; Przyborska, M.; Wasiak, J.; Wieczorkowski, M.

    2005-01-01

    In the paper the fundamental steels using in the construction of pressure vessel water reactor are discussed. The properties of these steels as well as the influence of neutron irradiation on its degradation in the time of exploitation are also done. (authors)

  4. GOLD PRESSURE VESSEL SEAL

    Science.gov (United States)

    Smith, A.E.

    1963-11-26

    An improved seal between the piston and die member of a piston-cylinder type pressure vessel is presented. A layer of gold, of sufficient thickness to provide an interference fit between the piston and die member, is plated on the contacting surface of at least one of the members. (AEC)

  5. Reactor vessel stud tensioner

    International Nuclear Information System (INIS)

    Malandra, L.J.; Beer, R.W.; Salton, R.B.; Spiegelman, S.R.; Cognevich, M.L.

    1982-01-01

    A quick-acting stud tensioner, for facilitating the loosening or tightening of a stud nut on a reactor vessel stud, has gripper jaws which when the tensioner is lowered into engagement with the upper end of the stud are moved inwards to grip the upper end and which when the tensioner is lifted move outward to release the upper end. (author)

  6. Nuclear reactor vessels

    International Nuclear Information System (INIS)

    Sato, Yoshimi; Fukuda, Yoshio.

    1987-01-01

    Purpose: To improve the strength and reliability by moderating thermal stresses produced to the furnace walls of a reactor vessel by the thermal shocks upon reactor shutdown and tripping and reducing the generation of developing thermal ratchet strains produced upon repeating thermal shocks. Constitution: Upon occurrence of reactor shutdown or tripping, the temperature is detected and the pressure of the cover gas is controlled such that the axial temperature slope is decreased to displace the liquid surface in an annular vessel. Then, for attaining the stress reducing temperature, control is so conducted that the temperature of the lower portion is not higher than the upper portion in the axial temperature distribution of the reactor vessel. By controlling the pressure of the cover gas in the annular vessel in this way, the liquid level can be raised to a cover gas portion remaining at a high temperature state. Further, the temperature of the furnace wall can always be decreased to a temperature of the high temperature plenum thereby enabling to moderate the thermal stresses. (Yoshihara, H.)

  7. Pressure vessel integrity 1991

    International Nuclear Information System (INIS)

    Bhandari, S.; Doney, R.O.; McDonald, M.S.; Jones, D.P.; Wilson, W.K.; Pennell, W.E.

    1991-01-01

    This volume contains papers relating to the structural integrity assessment of pressure vessels and piping, with special emphasis on nuclear industry applications. The papers were prepared for technical sessions developed under the sponsorship of the ASME Pressure Vessels and Piping Division Committees for Codes and Standards, Computer Technology, Design and Analysis, and Materials Fabrication. They were presented at the 1991 Pressure Vessels and Piping Division Conference in San Diego, California, June 23-27. The primary objective of the sponsoring organization is to provide a forum for the dissemination and discussion of information on development and application of technology for the structural integrity assessment of pressure vessels and piping. This publication includes contributions from authors from Australia, France, Japan, Sweden, Switzerland, the United Kingdom, and the United States. The papers here are organized in six sections, each with a particular emphasis as indicated in the following section titles: Fracture Technology Status and Application Experience; Crack Initiation, Propagation and Arrest; Ductile Tearing; Constraint, Stress State, and Local-Brittle-Zones Effects; Computational Techniques for Fracture and Corrosion Fatigue; and Codes and Standards for Fatigue, Fracture and Erosion/Corrosion

  8. Laser therapy in plastic surgery: decolorization in port wine stains

    Science.gov (United States)

    Peszynski-Drews, Cezary; Wolf, Leszek

    1996-03-01

    For the first time laserotherapy is described as a method of port wine stain decolorization in plastic surgery. The authors present their 20-year experience in the treatment of port wine stains with the argon laser and dye laser.

  9. Port wine stain on a child's face (image)

    Science.gov (United States)

    Port wine stains are always present at birth. In an infant, they are flat, pink, vascular lesions. Common locations ... may be present anywhere on the body. Port wine stains may appear in association with other syndromes.

  10. The degradation of Romanowsky-type blood stains in methanol.

    Science.gov (United States)

    Dean, W W; Stastny, M; Lubrano, G J

    1977-01-01

    The oxidative demethylation of Romanowsky-type stains in methanol has been examined quantitatively with respect to its effect upon the staining of blood smears. Spectral changes in bound dye, observed through two color filters, have been measured for the nuclei and cytoplasm of segmented neutrophils and monocytes utilizing the LARC automated differential analyzer. Stain decomposition in methanol results in a large loss in staining intensity with little change in color. The loss in intensity has been correlated with the observed spectral changes in the degraded stain. High-performance liquid chromatographic analysis of degraded stain samples has shown the products of methanolic degradation to be different from those obtained in aqueous polychroming reactions. To maintain a stain of defined thiazine dye composition and thus defined staining properties, refrigeration is recommended.

  11. Several staining techniques to enhance the visibility of Acanthamoeba cysts.

    Science.gov (United States)

    El-Sayed, Nagwa Mostafa; Hikal, Wafaa Mohamed

    2015-03-01

    Acanthamoeba is one of the most common free-living amoebae. It is widespread in the environment and can infect humans causing keratitis. Delayed diagnosis or misdiagnosis leads to extensive corneal inflammation and profound visual loss. Therefore, accurate and rapid diagnosis of Acanthamoeba keratitis is essential for successful treatment and good prognosis. This study was designed to use different staining techniques to facilitate the identification of Acanthamoeba cysts. Acanthamoeba cysts were isolated by cultivation of either corneal scraping specimens or tap water samples onto non-nutrient agar plates seeded with Escherichia coli. Subcultures were done from positive cultures until unique cysts were isolated. Acanthamoeba cysts were stained temporarily using iodine, eosin, methylene blue, and calcofluor white (CFW) stains and as permanent slides after processing for mounting using modified trichrome, Gimenez and Giemsa staining. These stains were compared on the basis of staining quality including clarity of morphological details, differentiation between cytoplasm and nuclei, color and contrast, and also other characteristics of the staining techniques, including ease of handling, time taken for the procedure, and cost effectiveness. The cysts of Acanthamoeba were recognized in the form of double-walled cysts: the outer wall (ectocyst) that was being differentiated from the variably stained surrounding background and the inner wall (endocyst) that was sometimes stellated, polygonal, round, or oval and visualized as separate from the spherical, sometimes irregular, outline of the ectocyst. Regarding the temporary stains, it was found that they were efficient for visualizing the morphological details of Acanthamoeba cysts. In CFW staining, Acanthamoeba cysts appeared as bluish-white or turquoise oval halos although the internal detail was not evident. On the other hand, the results of permanent-stained slides showed the most consistent stain for identification of

  12. PDX vacuum vessel stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.

    1975-01-01

    A stress analysis of PDX vacuum vessel is described and the summary of results is presented. The vacuum vessel is treated as a toroidal shell of revolution subjected to an internal vacuum. The critical buckling pressure is calculated. The effects of the geometrical discontinuity at the juncture of toroidal shell head and cylindrical outside wall, and the concavity of the cylindrical wall are examined. An effect of the poloidal field coil supports and the vessel outside supports on the stress distribution in the vacuum vessel is determined. A method evaluating the influence of circular ports in the vessel wall on the stress level in the vessel is outlined

  13. Dye purity and dye standardization for biological staining

    DEFF Research Database (Denmark)

    Lyon, H O

    2002-01-01

    for separating, identifying and assaying dye components. In the second part of the review, descriptions are given of the standardized staining method approach using standard staining methods for assessing stains, and practical responses to stain impurity including commercial quality control, third-party quality...... control and standardization of reagents, protocols and documentation. Finally, reference is made to the current state of affairs in the dye field....

  14. Comparison between Giemsa and Van Geison stains in ...

    African Journals Online (AJOL)

    Trichrome stain (such as Van Geison) is usually used in histopathology laboratory for demonstration of collagenic fibers. Lack of selectivity and tendency of stain to fade makes van Gieson not ideal for collagen demonstration. This study was aimed to compare between Giemsa's and van Gieson's stains in collagen fibers ...

  15. Modified ultrafast Papanicolaou staining technique: A comparative study

    Science.gov (United States)

    Thakur, Moni; Guttikonda, Venkateswara Rao

    2017-01-01

    Introduction: Ultrafast Papanicolaou stain (UFP) was introduced as a hybrid of Romanowsky and Papanicolaou (PAP) stain. It enhances the quality and reduces the time. In the present study, a modified staining technique was adapted where Gill's Hematoxylin was replaced by Harris Hematoxylin. Aims: The aim of the study was to assess the use of the modified ultrafast Papanicolaou (MUFP) stain for fine needle aspiration cytology (FNAC) of head and neck swellings in comparison with the routine PAP stain, hematoxylin and eosin (H and E), and Giemsa. Materials and Methods: Forty FNACs of head and neck swellings were collected. FNAC procedure was performed by standard method; two smears were fixed in 95% propanol and stained with PAP and H and E. Two smears were air dried, 1 was stained with Giemsa, and 1 was rehydrated with normal saline, fixed in alcoholic formalin, and stained with MUFP. Four parameters were considered and scored background, cell morphology, nuclear staining, and overall staining pattern). Results: The quality of MUFP smears were better when compared to routine PAP, H and E, and Giemsa, and was statistically significant by Wilcoxon matched pair test. Conclusions: MUFP stain in comparison to routine PAP, H and E, and Giemsa provides an excellent and suitable alterative in cytological staining for the study of various organs. PMID:28701828

  16. Modified ultrafast Papanicolaou staining technique: A comparative study

    Directory of Open Access Journals (Sweden)

    Moni Thakur

    2017-01-01

    Full Text Available Introduction: Ultrafast Papanicolaou stain (UFP was introduced as a hybrid of Romanowsky and Papanicolaou (PAP stain. It enhances the quality and reduces the time. In the present study, a modified staining technique was adapted where Gill's Hematoxylin was replaced by Harris Hematoxylin. Aims: The aim of the study was to assess the use of the modified ultrafast Papanicolaou (MUFP stain for fine needle aspiration cytology (FNAC of head and neck swellings in comparison with the routine PAP stain, hematoxylin and eosin (H and E, and Giemsa. Materials and Methods: Forty FNACs of head and neck swellings were collected. FNAC procedure was performed by standard method; two smears were fixed in 95% propanol and stained with PAP and H and E. Two smears were air dried, 1 was stained with Giemsa, and 1 was rehydrated with normal saline, fixed in alcoholic formalin, and stained with MUFP. Four parameters were considered and scored background, cell morphology, nuclear staining, and overall staining pattern. Results: The quality of MUFP smears were better when compared to routine PAP, H and E, and Giemsa, and was statistically significant by Wilcoxon matched pair test. Conclusions: MUFP stain in comparison to routine PAP, H and E, and Giemsa provides an excellent and suitable alterative in cytological staining for the study of various organs.

  17. Comparison between Giemsa and Van Geison stains in ...

    African Journals Online (AJOL)

    Rukevwe S. Abraka

    2016-09-14

    Sep 14, 2016 ... Trichrome stain (such as Van Geison) is usually used in histopathology laboratory for demonstration of collagenic fibers. Lack of selectivity and tendency of stain to fade makes van Gieson not ideal for collagen demonstration. This study was aimed to compare between Giemsa's and van Gieson's stains.

  18. 7 CFR 28.442 - Middling Yellow Stained Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Middling Yellow Stained Color. 28.442 Section 28.442... Stained Color. Middling Yellow Stained Color is American Upland cotton which in color is deeper than Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] below color grade cotton ...

  19. 7 CFR 28.441 - Strict Middling Yellow Stained Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Middling Yellow Stained Color. 28.441 Section... Strict Middling Yellow Stained Color. Strict Middling Yellow Stained Color is color which is deeper than that of Strict Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] ...

  20. itFISH: Enhanced Staining by Iterative Fluorescent In Situ Hybridization.

    Science.gov (United States)

    Row, Richard H; Martin, Benjamin L

    2017-12-01

    Fluorescent in situ hybridization (FISH) is an important tool for zebrafish research, particularly when observing the expression of two different genes in the same embryo. Peroxidase-catalyzed deposition of tyramide-conjugated dyes is a widely used and cost-effective approach to performing FISH. A major limitation of the technique is that it does not work well for weakly expressed genes. Here we present a method adapted from planarian research for use in zebrafish that provides a dramatic enhancement of weak staining. By iterating the antibody staining and development steps, a strong signal can be obtained from probes that were previously too weak to detect.

  1. Monitoring the magnitude of marine vessel infestation by non-indigenous ascidians in the Mediterranean.

    Science.gov (United States)

    Gewing, Mey-Tal; Shenkar, Noa

    2017-08-15

    Invasive ascidians (Chordata, Tunicata) are dominant nuisance organisms. The current study investigated the role of marine vessels in their dispersal and introduction. An examination of 45 dry-docked marine vessels, comprising recreational, commercial, and military craft, in five Israeli shipyards along the Mediterranean coast, revealed non-indigenous ascidians (NIA) on every second vessel investigated. Military vessels featured the highest ascidian abundance and richness, potentially related to their maintenance routine. Niche areas on the vessels such as sea chests and the propeller exhibited the highest occurrence of ascidians. Overall, these findings provide strong evidence that marine vessels play an acute role in NIA introduction and dispersal, with military vessels and niche areas on all the vessels being more susceptible to serving as vectors. A discovery of a new introduced species during the surveys suggests that the monitoring of marine vessels can serve as an effective tool for the early detection of NIA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Vessels in Transit - Web Tool

    Data.gov (United States)

    Department of Transportation — A web tool that provides real-time information on vessels transiting the Saint Lawrence Seaway. Visitors may sort by order of turn, vessel name, or last location in...

  3. Radiant vessel auxiliary cooling system

    Science.gov (United States)

    Germer, John H.

    1987-01-01

    In a modular liquid-metal pool breeder reactor, a radiant vessel auxiliary cooling system is disclosed for removing the residual heat resulting from the shutdown of a reactor by a completely passive heat transfer system. A shell surrounds the reactor and containment vessel, separated from the containment vessel by an air passage. Natural circulation of air is provided by air vents at the lower and upper ends of the shell. Longitudinal, radial and inwardly extending fins extend from the shell into the air passage. The fins are heated by radiation from the containment vessel and convect the heat to the circulating air. Residual heat from the primary reactor vessel is transmitted from the reactor vessel through an inert gas plenum to a guard or containment vessel designed to contain any leaking coolant. The containment vessel is conventional and is surrounded by the shell.

  4. Attachment Fitting for Pressure Vessel

    Science.gov (United States)

    Smeltzer, Stanley S., III (Inventor); Carrigan, Robert W. (Inventor)

    2002-01-01

    This invention provides sealed access to the interior of a pressure vessel and consists of a tube. a collar, redundant seals, and a port. The port allows the seals to be pressurized and seated before the pressure vessel becomes pressurized.

  5. [Effects of high intensity focused ultrasound with SonoVue on blood vessels pathological examinations].

    Science.gov (United States)

    Qin, Yan; Bai, Jin; Li, Faqi; Wang, Zhibiao

    2010-12-01

    The injury of tumor blood vessels will break up the nutrition supply for the tumor. In this paper, we investigated the effects exerted by high intensity focused ultrasound (HIFU) combined with ultrasound microbubble agent on blood vessels. Ultrasound diagnosis was used to find the goat hepatic blood vessels each being approximately 3mm in diameter. HIFU was focused on the blood vessels. The acoustic power was 250W; HIFU irradiating Mode was line scan (the length of the line: 10 mm; speed: 3 mm/s; irradiating time: 30s). In the experimental group, 0.03 ml/kg SonoVue was injected into the goat before HIFU irradiation,while normal saline was given to the control group. The goats were killed at 24h after HIFU irradiation, then goat liver tissues and blood vessels of target area were taken out. HE staining and Victoria's blue and Ponceau's staining of tissue section showed that the endothelial cells of blood vessels dropped off and became necrosed, and the continuity of blood vessels was interrupted. HIFU combined with SonoVue will damage large blood vessels on HIFU focus, but there is no evident discrepancy between the group with SonoVue and the group without SonoVue.

  6. Mobile nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Thompson, R.E.; Spurrier, F.R.; Jones, A.R.

    1978-01-01

    A containment vessel for use in mobile nuclear reactor installations is described. The containment vessel completely surrounds the entire primary system, and is located as close to the reactor primary system components as is possible in order to minimize weight. In addition to being designed to withstand a specified internal pressure, the containment vessel is also designed to maintain integrity as a containment vessel in case of a possible collision accident

  7. Spent fuel transporting vessel

    International Nuclear Information System (INIS)

    Kumagaya, Takeshi.

    1995-01-01

    A large number of annular cooling fins are disposed each at an equal distance on the outer circumferential surface of a vessel main body. An electric power generation module is disposed on the surface of the cooling fins. The electric power generation module comprises a plurality of thermoelectric power generation elements. In each of the thermoelectric generation elements, the inner side thereof in contact with the surface of the cooling fin is at a high temperature while the outer side thereof is at a low temperature nearly equal with an atmospheric temperature. A predetermined amount of electric power is generated by seebeck effect due to the temperature difference. The electric power is always stored in a battery. Accordingly, even if a power generator of a ship should fail and power supply is stopped during transportation of the vessels for spent nuclear fuels, an appropriate amount of electric power can be supplied to a cooling device of the ship. (I.N.)

  8. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    An apparatus is described for sealing a cold leg nozzle of a nuclear reactor pressure vessel from a remote location comprising: at least one sealing plug for mechanically sealing the nozzle from the inside of the reactor pressure vessel. The sealing plug includes a plate and a cone assembly having an end part receptive in the nozzle, the plate being axially moveable relative to the cone assembly. The plate and cone assembly have confronting bevelled edges defining an opening therebetween. A primary O-ring is disposed about the opening and is supported on the bevelled edges, the plate being guidably mounted to the cone assembly for movement toward the cone assembly to radially expand the primary O-ring into sealing engagement with the nozzle. A means is included for providing relative movement between the outer plate and the cone assembly

  9. Reactor Pressure Vessel Steels

    Energy Technology Data Exchange (ETDEWEB)

    Van de Velde, J.; Fabry, A.; Van Walle, E.; Chaoudi, R

    1998-07-01

    SCK-CEN's R and D programme on Reactor Pressure Vessel (RPV) Steels in performed in support of the RVP integrity assessment. Its main objectives are: (1) to develop enhanced surveillance concepts by applying micromechanics and fracture-toughness tests to small specimens, and by performing damage modelling and microstructure characterization; (2) to demonstrate the applied methodology on a broad database; (3) to achieve regulatory acceptance and industrial use. Progress and achievements in 1999 are reported.

  10. High pressure storage vessel

    Science.gov (United States)

    Liu, Qiang

    2013-08-27

    Disclosed herein is a composite pressure vessel with a liner having a polar boss and a blind boss a shell is formed around the liner via one or more filament wrappings continuously disposed around at least a substantial portion of the liner assembly combined the liner and filament wrapping have a support profile. To reduce susceptible to rupture a locally disposed filament fiber is added.

  11. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomenology of radiation-induced changes in blood vessels are systematized and authors' experience is generalized. Modern concepts about processes leading to vessel structure injury after irradiation is critically analyzed. Special attention is paid to reparation and compensation of X-ray vessel injury, consideration of which is not yet sufficiently elucidated in literature

  12. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomeology of radiation changes of blood vessels are systemized and the authors' experience is generalyzed. A critical analysis of modern conceptions on processes resulting in vessel structure damage after irradiation, is given. Special attention is paid to reparation and compensation of radiation injury of vessels

  13. Fabrication of mercury target vessel

    International Nuclear Information System (INIS)

    Wakui, Takashi; Kogawa, Hiroyuki; Haga, Katsuhiro; Futakawa, Masatoshi; Hayashi, Ryoichi; Uchiyama, Naoyoshi; Okamoto, Yoshinao; Nakamura, Koji

    2010-03-01

    The construction of materials and life science experimental facility in J-PARC (Japan Proton Accelerator Complex) project had been completed and accepted pulsed proton beams with low power. Since 2003, the detailed design, fabrication and examination for the mercury target vessel as a pulsed neutron source were carried out by the vender. The mercury target vessel consists of triple-walled structure in order to prevent the leak of mercury to outside at the failure of the mercury vessel and to remove the heat of the safety hull, which covers the mercury vessel, due to the injection of the pulsed proton beams. The high fabrication accuracy is required for the mercury target vessel assembled by the welding, because there are the relationships between the mercury target vessel and other components (target trolley, target storage container, flange of helium vessel, reflector and water-cooled shield). At each fabrication step, the examinations for the mercury target vessel with multi-walled structure were required. In this report, the required specification and basic structure of parts in the mercury target vessel are described and the fabrication procedure of the mercury target vessel by the vender is reported. In the fabrication of the mercury target vessel, there were many troubles such as large deformation due to the welding and then the vender repaired and brought the mercury target vessel to completion. Furthermore, improvements for the design and fabrication of the mercury target are reported. (author)

  14. Myeloperoxidase staining in the diagnosis of aggressive periodontitis.

    Science.gov (United States)

    Singh, Sukhdeep; Acharya, Anirudh B; Kumar, S C Veerendra

    2011-04-01

    To evaluate neutrophil myeloperoxidase (MPO) staining procedure as a reliable, affordable and easily available diagnostic assay for aggressive periodontitis. Fifteen subjects were recruited in the study wherein five each were diagnosed as aggressive periodontitis and chronic periodontitis respectively, and five were periodontally healthy. Three millilitres (ml) of venous blood was collected using Vacutainers containing ethylene diamine tetra acetate (EDTA) and was subjected to MPO staining procedure. Histological picture was evaluated using a visual analogue scale (VAS). MPO stained specimen of all the patients showed positive MPO staining of the neutrophils. The intensity of the stain of MPO granules was more in aggressive periodontitis specimen as compared to the chronic periodontitis patient specimen and healthy subject specimen. The staining characteristics were comparable for chronic periodontitis patients and healthy subject. This study shows that there is a potential and probable place for MPO staining as an economical, relatively convenient and easily available assay in the diagnosis of aggressive periodontitis.

  15. Reactor pressure vessel nozzle

    Science.gov (United States)

    Challberg, Roy C.; Upton, Hubert A.

    1994-01-01

    A nozzle for joining a pool of water to a nuclear reactor pressure vessel includes a tubular body having a proximal end joinable to the pressure vessel and a distal end joinable in flow communication with the pool. The body includes a flow passage therethrough having in serial flow communication a first port at the distal end, a throat spaced axially from the first port, a conical channel extending axially from the throat, and a second port at the proximal end which is joinable in flow communication with the pressure vessel. The inner diameter of the flow passage decreases from the first port to the throat and then increases along the conical channel to the second port. In this way, the conical channel acts as a diverging channel or diffuser in the forward flow direction from the first port to the second port for recovering pressure due to the flow restriction provided by the throat. In the backflow direction from the second port to the first port, the conical channel is a converging channel and with the abrupt increase in flow area from the throat to the first port collectively increase resistance to flow therethrough.

  16. Pressure controlled clamp using shape memory alloy for minimal vessel invasion in blood flow occlusion.

    Science.gov (United States)

    Zhang, Ye; Kanetaka, Hiroyasu; Sano, Yuya; Kano, Mitsuhiro; Kudo, Tadaaki; Sato, Takumi; Shimizu, Yoshinaka

    2013-01-01

    Vessel damage after clamping may affect the success of surgical operations. A new pressure controlled clamp (SMA clamp) was designed using super elastic property of shape memory alloy (SMA) to realize atraumatic vessel occlusion. The ability and biological effect of the SMA clamp to control pressure was investigated in vivo. The loading-displacement curves of the SMA clamps (experimental group) and conventional clamp (control group) by occlusion of pig carotid arteries were evaluated using a clamping-pressure analyzing system. To investigate macroscopically and histologically the vessel damage of the SMA and conventional clamps, pig carotid arteries were stained with Evan's blue and its histological sections were stained with Elastica Massion after clamping for fifteen minutes. Constant value was shown in the loading-displacement curve of SMA clamp. In the control group, damaged area stained with Evan's blue in the vessel wall showed enlargement with the pressure increasing. Less areas in experimental groups are observed than that in the control group. Histological section in the experimental group showed no obvious except a slight compressive damage in the tunica intima. In the control group, vessel wall showed irreversible damages. This experiment indicated that the SMA clamp, which has a unique mechanical property, can be used without vessels damage. This pressure controlled clamp can be a selection in clinical apparatus to improve surgical safety.

  17. Refractile mycobacteria in Romanowsky-stained bone marrow smears. A comparison of acid-fast-stained tissue sections and Romanowsky-stained smears.

    Science.gov (United States)

    Torlakovic, E; Clayton, F; Ames, E D

    1992-03-01

    The appearance of mycobacteria was studied in Wright-stained bone marrow preparations of human immunodeficiency virus-infected patients and compared with acid-fast-stained trephine biopsy sections and culture results. Mycobacterium avium complex in Romanowsky-stained preparations may be seen as extracellular and intracellular clear or red refractile beaded rods and nonrefractile "negative images." Refractile mycobacteria were seen in 17 of 20 culture-positive cases. Acid-fast stain of the trephine biopsy demonstrated organisms in only 11 of the 20 cases. Thus, six cases were culture positive and contained refractile rods but had no acid-fast organisms on the trephine biopsy. No false-positive results were seen with Romanowsky stain; the three false-negative results for refractility also were negative with acid-fast stain. Examination of Romanowsky-stained smears or imprints for refractile mycobacteria provides a reliable and sensitive method to identify mycobacteria in this population. Romanowsky-stained bone marrow aspirate and imprint smears should be examined for refractile bacilli when mycobacterial infection is suspected.

  18. Erbium doped stain etched porous silicon

    International Nuclear Information System (INIS)

    Gonzalez-Diaz, B.; Diaz-Herrera, B.; Guerrero-Lemus, R.; Mendez-Ramos, J.; Rodriguez, V.D.; Hernandez-Rodriguez, C.; Martinez-Duart, J.M.

    2008-01-01

    In this work a simple erbium doping process applied to stain etched porous silicon layers (PSLs) is proposed. This doping process has been developed for application in porous silicon solar cells, where conventional erbium doping processes are not affordable because of the high processing cost and technical difficulties. The PSLs were formed by immersion in a HF/HNO 3 solution to properly adjust the porosity and pore thickness to an optimal doping of the porous structure. After the formation of the porous structure, the PSLs were analyzed by means of nitrogen BET (Brunauer, Emmett and Teller) area measurements and scanning electron microscopy. Subsequently, the PSLs were immersed in a saturated erbium nitrate solution in order to cover the porous surface. Then, the samples were subjected to a thermal process to activate the Er 3+ ions. Different temperatures and annealing times were used in this process. The photoluminescence of the PSLs was evaluated before and after the doping processes and the composition was analyzed by Fourier transform IR spectroscopy

  19. Quantitative comparison of immunohistochemical staining measured by digital image analysis versus pathologist visual scoring

    Science.gov (United States)

    2012-01-01

    Abstract Immunohistochemical (IHC) assays performed on formalin-fixed paraffin-embedded (FFPE) tissue sections traditionally have been semi-quantified by pathologist visual scoring of staining. IHC is useful for validating biomarkers discovered through genomics methods as large clinical repositories of FFPE specimens support the construction of tissue microarrays (TMAs) for high throughput studies. Due to the ubiquitous availability of IHC techniques in clinical laboratories, validated IHC biomarkers may be translated readily into clinical use. However, the method of pathologist semi-quantification is costly, inherently subjective, and produces ordinal rather than continuous variable data. Computer-aided analysis of digitized whole slide images may overcome these limitations. Using TMAs representing 215 ovarian serous carcinoma specimens stained for S100A1, we assessed the degree to which data obtained using computer-aided methods correlated with data obtained by pathologist visual scoring. To evaluate computer-aided image classification, IHC staining within pathologist annotated and software-classified areas of carcinoma were compared for each case. Two metrics for IHC staining were used: the percentage of carcinoma with S100A1 staining (%Pos), and the product of the staining intensity (optical density [OD] of staining) multiplied by the percentage of carcinoma with S100A1 staining (OD*%Pos). A comparison of the IHC staining data obtained from manual annotations and software-derived annotations showed strong agreement, indicating that software efficiently classifies carcinomatous areas within IHC slide images. Comparisons of IHC intensity data derived using pixel analysis software versus pathologist visual scoring demonstrated high Spearman correlations of 0.88 for %Pos (p < 0.0001) and 0.90 for OD*%Pos (p < 0.0001). This study demonstrated that computer-aided methods to classify image areas of interest (e.g., carcinomatous areas of tissue specimens) and

  20. Strong transthyretin immunostaining: potential pitfall in cardiac amyloid typing.

    Science.gov (United States)

    Satoskar, Anjali A; Efebera, Yvonne; Hasan, Ayesha; Brodsky, Sergey; Nadasdy, Gyongyi; Dogan, Ahmet; Nadasdy, Tibor

    2011-11-01

    Although systemic amyloidosis commonly presents with renal disease, cardiac involvement usually determines the patient's prognosis. Cardiac involvement is seen in light chain amyloid and transthyretin amyloidosis. Distinguishing between these two is critical because prognosis and treatment differ. Our study demonstrates the unreliability of transthyretin immunostaining in subtyping cardiac amyloid. Between January 2003 and August 2010, we retrieved 229 native endomyocardial biopsies, of which 24 had amyloid. Immunohistochemistry for κ, λ, transthyretin, and serum amyloid A protein was performed on formalin-fixed, paraffin-embedded sections. Staining was graded as weak (trace to 1+) or strong (2 to 3+). Mass spectrometry (MS)-based proteomic typing of microdissected amyloid material was performed on selected cases. Fifteen patients had monoclonal gammopathy/plasma cell dyscrasia with cardiac amyloid. Eight of them (53%) showed strong transthyretin staining in the cardiac amyloid deposits. MS was performed in 5 of these 8 biopsies, and all 5 biopsies revealed light chain amyloid-type amyloid. Two of these 5 light chain amyloid biopsies did not even have concomitant strong staining for the appropriate light chain. Among the 15 cases with plasma cell dyscrasia, only 7 biopsies showed strong staining for the corresponding monoclonal light chain. Strong, false-positive immunostaining for transthyretin in cardiac amyloid is a potential pitfall, augmented by the frequent lack of staining for immunoglobulin light chains. Therefore, the presence of amyloid in the cardiac biopsy should prompt a search for plasma cell dyscrasia irrespective of transthyretin staining. Confirmation with MS should be sought, particularly if there is any discrepancy between κ/λ staining and serum immunofixation results.

  1. Survival of Pseudomonas aeruginosa in modified Romanowsky staining solutions.

    Science.gov (United States)

    Duffield, Richard; Wong, Hui-San; Trott, Darren J; Hill, Peter B

    2015-08-01

    Anecdotal reports suggest that rapid staining solutions can become contaminated with micro-organisms, especially Pseudomonas aeruginosa. To determine whether inoculation of rapid Romanowsky-type stains with P. aeruginosa results in viable bacterial contamination, which could lead to cross-contamination of slides during cytological staining. Pseudomonas aeruginosa was inoculated into clean and organically contaminated staining solutions (fixative, eosin and methylene blue) and positive (broth) and negative (bleach) control solutions. Subsequent viability and survival were detected by measuring colony-forming units per millilitre at various time points up to 2 weeks. Each sample was stained and microscopically examined to determine whether bacteria were visible. No bacteria could be cultured at any time point from the bleach or fixative solution. In clean eosin and methylene blue staining solutions, viable bacteria were recovered for up to 1 h, but by 24 h all bacteria were dead. In staining solutions contaminated with hair and dead skin cells, bacteria survived in methylene blue for up to 1 h, and viable bacteria persisted in the eosin stain for 2 weeks. In solutions containing viable organisms, the bacteria could be observed by microscopic examination; no bacteria were visible when the solutions contained no viable organisms. Pseudomonas aeruginosa can survive in commonly used staining solutions for variable periods of time, but is unable to proliferate. Although theoretically this might complicate cytological interpretation and subsequent diagnosis, the likelihood of this in clinical practice appears remote when the correct staining technique is used. © 2015 ESVD and ACVD.

  2. Grading vascularity from histopathological images based on traveling salesman distance and vessel size

    Science.gov (United States)

    Niazi, M. Khalid Khan; Hemminger, Jessica; Kurt, Habibe; Lozanski, Gerard; Gurcan, Metin

    2014-03-01

    Vascularity represents an important element of tissue/tumor microenvironment and is implicated in tumor growth, metastatic potential and resistence to therapy. Small blood vessels can be visualized using immunohistochemical stains specific to vascular cells. However, currently used manual methods to assess vascular density are poorly reproducible and are at best semi quantitative. Computer based quantitative and objective methods to measure microvessel density are urgently needed to better understand and clinically utilize microvascular density information. We propose a new method to quantify vascularity from images of bone marrow biopsies stained for CD34 vascular lining cells protein as a model. The method starts by automatically segmenting the blood vessels by methods of maxlink thresholding and minimum graph cuts. The segmentation is followed by morphological post-processing to reduce blast and small spurious objects from the bone marrow images. To classify the images into one of the four grades, we extracted 20 features from the segmented blood vessel images. These features include first four moments of the distribution of the area of blood vessels, first four moments of the distribution of 1) the edge weights in the minimum spanning tree of the blood vessels, 2) the shortest distance between blood vessels, 3) the homogeneity of the shortest distance (absolute difference in distance between consecutive blood vessels along the shortest path) between blood vessels and 5) blood vessel orientation. The method was tested on 26 bone marrow biopsy images stained with CD34 IHC stain, which were evaluated by three pathologists. The pathologists took part in this study by quantifying blood vessel density using gestalt assessment in hematopoietic bone marrow portions of bone marrow core biopsies images. To determine the intra-reader variability, each image was graded twice by each pathologist with two-week interval in between their readings. For each image, the ground

  3. A contribution to the histological study of hypercementosis using metal staining.

    Science.gov (United States)

    Lia, R C; Lauand, F; Marcantonio, E; Neto, C B

    1978-01-01

    After studying hypercementosis, in detail using metallic staining procedures, the authors reached the following conclusions: (1) The histology of hypercementosis, observed by metallic staining reveals remarkable and characteristic microscopical alterations. (2) The Rio Hortega12 procedures, the mitochondria technique of Polak,10 and the method of Achucarro-Hortega13 are of great value for the study of the morphology of cementum. (3) Among the technical procedures used, we consider the 1916 method of Achucarro-Hortega as affording the best view of cementocytes. (4) The Sharpey fibers, revealing great irregularity in course, shape and size, and frequent interruptions could be clearly observed; heavily stained lacunae were frequently observed along the cementum-dentin border; a direct deposit of cellular cementum on the dentin in the middle third of the root was frequently observed. Curiously, an acellular cementum deposit next to a cellular cementum layer could be observed; we also noted numerous cementocytes of different shapes and sizes, at times exhibiting alterations of a degenerative type, particularly fragmentation of protoplasmic prolongations. (5) The techniques used also showed the frequency of blood vessels in the texture of hyperplastic cementum and the presence of capillaries near cementum-dentin junction.

  4. Toward digital staining using stimulated Raman scattering and statistical machine learning

    Science.gov (United States)

    Tanji, K.; Otsuka, Y.; Satoh, S.; Hashimoto, H.; Ozeki, Y.; Itoh, Kazuyoshi

    2014-03-01

    Stimulated Raman scattering (SRS) spectral microscopy is a promising imaging method, based on vibrational spectroscopy, which can visualize biological tissues with chemical specificity. SRS spectral microscopy has been used to obtain two-dimensional spectral images of rat liver tissue, three-dimensional images of a vessel in rat liver, and in vivo spectral images of mouse ear skin. Various multivariate analysis techniques, such as principal component analysis and independent component analysis, have been used to obtain spectral images. In this study, we propose a digital staining method. This method uses SRS spectra and statistical machine learning that makes use of prior knowledge of spectral peaks and their two-dimensional distributional patterns corresponding to the composition of tissue samples. The method selects spectral peaks on the basis of Mahalanobis distance, which is defined as the ratio of inter-group variation to intragroup variation. We also make use of higher-order local autocorrelations as feature values for two-dimensional distributional patterns. This combination of techniques allows groups corresponding to different intracellular structures to be clearly discriminated in the multidimensional feature space. We investigate the performance of our method on mouse liver tissue samples and show that the proposed method can digitally stain each intracellular structure such as cell nuclei, cytoplasm, and erythrocytes separately and clearly without time-consuming chemical staining processes. We anticipate that our method could be applied to computer-aided pathological diagnosis.

  5. Intravascular perfusion of carbon black ink allows reliable visualization of cerebral vessels.

    Science.gov (United States)

    Hasan, Mohammad R; Herz, Josephine; Hermann, Dirk M; Doeppner, Thorsten R

    2013-01-04

    The anatomical structure of cerebral vessels is a key determinant for brain hemodynamics as well as the severity of injury following ischemic insults. The cerebral vasculature dynamically responds to various pathophysiological states and it exhibits considerable differences between strains and under conditions of genetic manipulations. Essentially, a reliable technique for intracranial vessel staining is essential in order to study the pathogenesis of ischemic stroke. Until recently, a set of different techniques has been employed to visualize the cerebral vasculature including injection of low viscosity resin, araldite F, gelatin mixed with various dyes (i.e. carmine red, India ink) or latex with or without carbon black. Perfusion of white latex compound through the ascending aorta has been first reported by Coyle and Jokelainen. Maeda et al. have modified the protocol by adding carbon black ink to the latex compound for improved contrast visualization of the vessels after saline perfusion of the brain. However, inefficient perfusion and inadequate filling of the vessels are frequently experienced due to high viscosity of the latex compound. Therefore, we have described a simple and cost-effective technique using a mixture of two commercially available carbon black inks (CB1 and CB2) to visualize the cerebral vasculature in a reproducible manner. We have shown that perfusion with CB1+CB2 in mice results in staining of significantly smaller cerebral vessels at a higher density in comparison to latex perfusion. Here, we describe our protocol to identify the anastomotic points between the anterior (ACA) and middle cerebral arteries (MCA) to study vessel variations in mice with different genetic backgrounds. Finally, we demonstrate the feasibility of our technique in a transient focal cerebral ischemia model in mice by combining CB1+CB2-mediated vessel staining with TTC staining in various degrees of ischemic injuries.

  6. Harmonization of the intracellular cytokine staining assay.

    Science.gov (United States)

    Welters, Marij J P; Gouttefangeas, Cécile; Ramwadhdoebe, Tamara H; Letsch, Anne; Ottensmeier, Christian H; Britten, Cedrik M; van der Burg, Sjoerd H

    2012-07-01

    Active immunotherapy for cancer is an accepted treatment modality aiming to reinforce the T-cell response to cancer. T-cell reactivity is measured by various assays and used to guide the clinical development of immunotherapeutics. However, data obtained across different institutions may vary substantially making comparative conclusions difficult. The Cancer Immunotherapy Immunoguiding Program organizes proficiency panels to identify key parameters influencing the outcome of commonly used T-cell assays followed by harmonization. Our successes with IFNγ-ELISPOT and peptide HLA multimer analysis have led to the current study on intracellular cytokine staining (ICS). We report the results of three successive panels evaluating this assay. At the beginning, 3 out of 9 participants (33 %) were able to detect >6 out of 8 known virus-specific T-cell responses in peripheral blood of healthy individuals. This increased to 50 % of the laboratories in the second phase. The reported percentages of cytokine-producing T cells by the different laboratories were highly variable with coefficients of variation well over 60 %. Variability could partially be explained by protocol-related differences in background cytokine production leading to sub-optimal signal-to-noise ratios. The large number of protocol variables prohibited identification of prime guidelines to harmonize the assays. In addition, the gating strategy used to identify reactive T cells had a major impact on assay outcome. Subsequent harmonization of the gating strategy considerably reduced the variability within the group of participants. In conclusion, we propose that first basic guidelines should be applied for gating in ICS experiments before harmonizing assay protocol variables.

  7. Green Arctic Patrol Vessel

    Science.gov (United States)

    2011-08-01

    Complement Flexible space for hovercraft , airboats, USVs and RHIBs Naval Surface Warfare Center Carderock Division Green Arctic Patrol Vessel 1...through Sea State 3 (SS3). Flexible capability for a variety of organic craft, such as boat, hovercraft and/or Unmanned Underwater Vehicles (UUVs...2.0, Finland 6.0 2.7 2.8 6 1.8 Hovercraft Griffon/500TD 8.04 3.92 2.41 99 5 ~1.5 Hovercraft Griffon/2000TD 12.7 6.1 3.93 450 20

  8. A useful single-solution polychrome stain for plant material...Brook Cyte-Chrome I.

    Science.gov (United States)

    Stanley L Krugman; Julia F. Littlefield

    1968-01-01

    Fresh and chemically fixed sectioned plant material can be quickly stained by applying a Brook Cyte Chrome I polychrome stain. Staining time averaged only about 10 minutes. And exact timing of staining and de-staining is not as critical as with most of the commonly used stains. The overall quality is comparable to that of the traditional stains.

  9. Testing strong interaction theories

    International Nuclear Information System (INIS)

    Ellis, J.

    1979-01-01

    The author discusses possible tests of the current theories of the strong interaction, in particular, quantum chromodynamics. High energy e + e - interactions should provide an excellent means of studying the strong force. (W.D.L.)

  10. Hoffman's violet and dahlia as specific stains for animal chromosomes.

    Science.gov (United States)

    Dutt, M K

    1979-03-01

    The paper deals with staining of the chromosomes of animal testicular materials with two basic dyes, Hoffman's violet and dahlia of the triphenylmethane group, following iodine-dye procedure. The important finding, as presented herein, is that iodinated alcohol after staining can be substituted with various acids, both organic as well as inorganic, all of which act as trapping agent preventing leaching of the dye that binds with the chromosomal DNA. It is clear from this study that RNA is not involved by this process of staining, since treatment of stained sections with cold phosphoric acid at 5 degrees C for 20--25 min and then stained also reveals perfect colouration of the chromosomes without any cytoplasmic staining. The in vitro absorption properties of Hoffman's violet have also been presented herein. The probable mechanism of action of these dyes has been suggested.

  11. Efficacy test of a toothpaste in reducing extrinsic dental stain

    Science.gov (United States)

    Agustanti, A.; Ramadhani, S. A.; Adiatman, M.; Rahardjo, A.; Callea, M.; Yavuz, I.; Maharani, D. A.

    2017-08-01

    This clinical trial compared the external dental stain reduction achieved by tested toothpaste versus placebo in adult patients. In this double-blind, parallel, randomised clinical trial, 45 female volunteers with a mean age of 20 years old were included. All study subjects front teeth were topically applicated with Silver Diamine Fluoride (SDF) to create external dental stains. Subjects were randomized into test (n=22) and control (n=23) groups. Toothpastes were used for two days to analyse the effects of removing external stains on the labial surfaces of all anterior teeth. VITA Easyshade Advance 4.0 was used to measure dental extrinsic stains changes. The analysis showed statistically significant efficacy of the tested toothpaste in reducing external dental stain caused by SDF, comparing to the placebo toothpaste, after one and two days of usage. The tested toothpaste was effective in reducing dental stain.

  12. Techniques for controlling variability in gram staining of obligate anaerobes.

    Science.gov (United States)

    Johnson, M J; Thatcher, E; Cox, M E

    1995-01-01

    Identification of anaerobes recovered from clinical samples is complicated by the fact that certain gram-positive anaerobes routinely stain gram negative; Peptostreptococcus asaccharolyticus, Eubacterium plautii, Clostridium ramosum, Clostridium symbiosum, and Clostridium clostridiiforme are among the nonconformists with regard to conventional Gram-staining procedures. Accurate Gram staining of American Type Culture Collection strains of these anaerobic bacteria is possible by implementing fixing and staining techniques within a gloveless anaerobic chamber. Under anaerobic conditions, gram-positive staining occurred in all test organisms with "quick" fixing techniques with both absolute methanol and formalin. The results support the hypothesis that, when anaerobic bacteria are exposed to oxygen, a breakdown of the physical integrity of the cell wall occurs, introducing Gram stain variability in gram-positive anaerobes. PMID:7538512

  13. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    Science.gov (United States)

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram

  14. TREATMENTS TO MINIMIZE EXTRACTIVES STAIN IN WESTERN RED CEDAR

    OpenAIRE

    Rod Stirling,; Paul I. Morris

    2012-01-01

    Under certain conditions involving uneven exposure to weather, stains related to the extractives can reduce the aesthetic appeal of western red cedar in exterior applications such as fence boards, siding, and sidewall shingles. Selected chemical treatments were evaluated for their ability to inhibit the formation of extractives stain. DDACarbonate, alkyl amine oxide, and combinations thereof delayed extractives stain formation in an accelerated field test, with higher loadings having greater ...

  15. Near-UV laser treatment of extrinsic dental enamel stains.

    Science.gov (United States)

    Schoenly, J E; Seka, W; Featherstone, J D B; Rechmann, P

    2012-04-01

    The selective ablation of extrinsic dental enamel stains using a 400-nm laser is evaluated at several fluences for completely removing stains with minimal damage to the underlying enamel. A frequency-doubled Ti:sapphire laser (400-nm wavelength, 60-nanosecond pulse duration, 10-Hz repetition rate) was used to treat 10 extracted human teeth with extrinsic enamel staining. Each tooth was irradiated perpendicular to the surface in a back-and-forth motion over a 1-mm length using an ∼300-µm-diam 10th-order super-Gaussian beam with fluences ranging from 0.8 to 6.4 J/cm(2) . Laser triangulation determined stain depth and volume removed by measuring 3D surface images before and after irradiation. Scanning electron microscopy evaluated the surface roughness of enamel following stain removal. Fluorescence spectroscopy measured spectra of unbleached and photobleached stains in the spectral range of 600-800 nm. Extrinsic enamel stains are removed with laser fluences between 0.8 and 6.4 J/cm(2) . Stains removed on sound enamel leave behind a smooth enamel surface. Stain removal in areas with signs of earlier cariogenic acid attacks resulted in isolated and randomly located laser-induced, 50-µm-diam enamel pits. These pits contain 0.5-µm diam, smooth craters indicative of heat transfer from the stain to the enamel and subsequent melting and water droplet ejection. Ablation stalling of enamel stains is typically observed at low fluences (<3 J/cm(2) ) and is accompanied by a drastic reduction in porphyrin fluorescence from the Soret band. Laser ablation of extrinsic enamel stains at 400 nm is observed to be most efficient above 3 J/cm(2) with minimal damage to the underlying enamel. Unsound underlying enamel is also observed to be selectively removed after irradiation. Copyright © 2012 Wiley Periodicals, Inc.

  16. Studies on the blue-staining fungi of pine wood

    Directory of Open Access Journals (Sweden)

    A. Strzelczyk

    2014-11-01

    Full Text Available The aim of this was were to examine associations of bule-staining fungi which occur on pine wood to determine the interactions between fungi and to check the suscebility of these fungi to commonly used fungieides. The stron antagonism of members of the Trichoderma genus against the blue-staining fungi was demonstrated, Members of genera Pullularia, Hormiscium and Hormodendrum were strongy inhibited by stains of Trichoderma Ophiostoma strains were less susceptible to inhibition by this antagonist.

  17. Reticular Basement Membrane Vessels Are Increased in COPD Bronchial Mucosa by Both Factor VIII and Collagen IV Immunostaining and Are Hyperpermeable

    Directory of Open Access Journals (Sweden)

    Amir Soltani

    2012-01-01

    Full Text Available Background and Objective. Using Collagen IV staining, we have previously reported that the reticular basement membrane (Rbm is hypervascular and the lamina propria (LP is hypovascular in COPD airways. This study compared Collagen IV staining with vessels marked with anti-Factor VIII and examined vessel permeability in bronchial biopsies from COPD and normal subjects using albumin staining. Results. Anti-Collagen IV antibody detected more vessels in the Rbm (P=0.002 and larger vessels in both Rbm (P<0.001 and LP (P=0.003 compared to Factor VIII. COPD airways had more vessels (with greater permeability in the Rbm (P=0.01 and fewer vessels (with normal permeability in the LP compared to controls with both Collagen IV and Factor VIII antibodies (P=0.04 and P=0.01. Conclusion. Rbm vessels were increased in number and were hyperpermeable in COPD airways. Anti-Collagen IV and anti-Factor VIII antibodies did not uniformly detect the same vessel populations; the first is likely to reflect larger and older vessels with the latter reflecting smaller, younger vessels.

  18. [Histochemical stains for minerals by hematoxylin-lake method].

    Science.gov (United States)

    Miyagawa, Makoto

    2013-04-01

    The present study was undertaken to establish the experimental animal model by histological staining methods for minerals. After intraperitoneal injections of minerals, precipitates deposited on the surface of the liver. Liver tissues were fixed in paraformaldehyde, embedded in paraffin and cut into thin sections which were used as minerals containing standard section. Several reagents for histological stains and spectrophotometry for minerals were applied in both test-tube experiments and stainings of tissue sections to test for minerals. Hematoxylin-lake was found of capable of staining minerals in tissue. A simple technique used was described for light microscopic detection of minerals.

  19. Histopathological evaluation of ocular microsporidiosis by different stains

    Directory of Open Access Journals (Sweden)

    Sharma Savitri

    2006-06-01

    Full Text Available Abstract Background There is limited data on comparing stains in the detection of microsporidia in corneal biopsies. Hence we wanted to evaluate various stains for their ability to detect microsporidia in corneal tissue sections. Methods Four cases diagnosed with microsporidiosis on Hematoxylin and Eosin and Periodic Acid Schiff's stained sections of the corneal button between January 2002 and December 2004, were included. Further sections were prospectively stained with calcofluor white, Gram, Giemsa, Masson's trichrome, acridine orange, Gomori's methenamine silver, Gram's chromotrope and modified acid fast stain. The stained sections were analyzed for the spore characteristics in terms of size, shape, color contrast, cell wall morphology, waist band in cytoplasm and ease of detection. Results All sections showed microsporidial spores as 3 – 5 μm, oval bodies. 1% acid fast, Gram's chromotrope and GMS stains provided a reliable diagnosis of microsporidia as diagnostic waist band could be identified and good contrast helped distinguish the spores from inflammatory debris. Conclusion Considering the ease of performance, cost effectiveness and rapidity of the technique, 1% acid fast stain and Gram's chromotrope stain are ideal for the detection of microsporidia.

  20. Reliability of a rapid hematology stain for sputum cytology

    OpenAIRE

    Gonçalves, Jéssica; Pizzichini, Emilio; Pizzichini, Marcia Margaret Menezes; Steidle, Leila John Marques; Rocha, Cristiane Cinara; Ferreira, Samira Cardoso; Zimmermann, Célia Tânia

    2014-01-01

    Objective: To determine the reliability of a rapid hematology stain for the cytological analysis of induced sputum samples. Methods: This was a cross-sectional study comparing the standard technique (May-Grünwald-Giemsa stain) with a rapid hematology stain (Diff-Quik). Of the 50 subjects included in the study, 21 had asthma, 19 had COPD, and 10 were healthy (controls). From the induced sputum samples collected, we prepared four slides: two were stained with May-Grünwald-Giemsa, and two w...

  1. Black stain and dental caries in Filipino schoolchildren.

    Science.gov (United States)

    Heinrich-Weltzien, Roswitha; Monse, Bella; van Palenstein Helderman, Wim

    2009-04-01

    Black stain is defined as dark pigmented exogenous substance in lines or dots parallel to the gingival margin and firmly adherent to the enamel at the cervical third of the tooth crowns in the primary and permanent dentition. This study was conducted to assess the prevalence of black stain on teeth of Filipino children and to determine a possible association between black stain and caries levels. The study was designed to test the following hypotheses: (i) the prevalence of black stain does not differ between children from schools with oral health intervention programs and those from schools without an intervention program, (ii) the prevalence of black stain does not differ in children attending easily accessible and remote schools, (iii) caries prevalence and caries experience do not differ in children with and without black stain and (iv) the caries distribution at the surface level does not differ in children with and without black stain. In total, 32 elementary schools were included. 19 schools with a comprehensive school-based preventive oral health program, seven schools with a basic preventive program and six control schools. All sixth graders of these schools (n=1748) aged 11.7+/-1.1 years were clinically examined for black stain. DMFT was assessed in 1121 children by seven calibrated dentists using WHO criteria. DMFS was scored in 627 children by two calibrated dentists. Black stain was found in 16% of this population. The prevalence of black stain did not differ significantly between children attending schools with different oral health intervention programs. Thus, hypothesis 1 was accepted. The prevalence of black stain was significantly higher (Pcaries prevalence and caries experience than children without black stain. Thus, hypothesis 3 was rejected. No difference was found in the DMFS pattern of occlusal, smooth and proximal surfaces between children with and without black stain. Thus hypothesis 4 was accepted. The presence of black stain is

  2. An automated vessel segmentation of retinal images using multiscale vesselness

    International Nuclear Information System (INIS)

    Ben Abdallah, M.; Malek, J.; Tourki, R.; Krissian, K.

    2011-01-01

    The ocular fundus image can provide information on pathological changes caused by local ocular diseases and early signs of certain systemic diseases, such as diabetes and hypertension. Automated analysis and interpretation of fundus images has become a necessary and important diagnostic procedure in ophthalmology. The extraction of blood vessels from retinal images is an important and challenging task in medical analysis and diagnosis. In this paper, we introduce an implementation of the anisotropic diffusion which allows reducing the noise and better preserving small structures like vessels in 2D images. A vessel detection filter, based on a multi-scale vesselness function, is then applied to enhance vascular structures.

  3. Computerized Reconstruction of Pulpal Blood Vessels Examined under Confocal Microscope

    Directory of Open Access Journals (Sweden)

    Digka Anna

    2015-03-01

    Full Text Available The purpose of this study was the evaluation of 3 different histological methods for studying pulpal blood vessels in combination with 2 types of confocal microscope and computer assisted 3-dimensional reconstruction. 10 human, healthy, free of restorations or caries teeth that were extracted for orthodontic reasons were used. From these teeth, the pulp tissues of 5 were removed, fixed in formalin solution, dehydrated and embedded in paraffin. Serial cross sections 5μm thick were taken from 3 of the above mentioned pulpal tissues and stained with CD34 according to the immunohistochemical ABC technique, while the rest 2 were stained with CD34 and Cy5 by means of immunofluorescence after serial cross sectioning of 10μm. 5 of the 10 teeth were fixed, decalcified, serial cross sectioned (30μm thickness and stained with eosin. The physical sections were examined under 2 types of confocal laser microscope. Serial images were taken for each section, alignment of the images was followed and finally 3-dimensional reconstructions of the pulpal vessels were achieved.

  4. Three-dimensional reconstruction of rat dermal blood vessels in vivo

    Science.gov (United States)

    Barton, Jennifer K.; Izatt, Joseph A.; Kulkarni, Manish D.; Welch, Ashley J.

    1997-05-01

    We performed imaging and reconstruction of dermal and subdermal blood vessels in a rat skin flap window model. The window model consists of a double thickness of dorsal skin which is sutured to a holding fixture. A 1 cm circle of skin is removed from one thickness, exposing the dermal blood vessels of the opposing side. An optical coherence tomography system operating at 1310 nm was used to image the blood vessels. A series of transverse images of the window model characterized sections of tissue. Off-the-shelf software for desktop and workstation computers was used to preprocess the images, identify and reconstruct blood vessels, and to extract parameters such depth, diameter, and percent volume of blood vessels. Such parameters may be of interest in developing improved treatments for vascular disorders such as port wine stains.

  5. The vessel fluence; Fluence cuve

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This book presents the proceedings of the technical meeting on the reactors vessels fluence. They are grouped in eight sessions: the industrial context and the stakes of the vessels control; the organization and the methodology for the fluence computation; the concerned physical properties; the reference computation methods; the fluence monitoring in an industrial context; vessels monitoring under irradiation; others methods in the world; the research and development programs. (A.L.B.)

  6. Zooming in: high resolution 3D reconstruction of differently stained histological whole slide images

    Science.gov (United States)

    Lotz, Johannes; Berger, Judith; Müller, Benedikt; Breuhahn, Kai; Grabe, Niels; Heldmann, Stefan; Homeyer, André; Lahrmann, Bernd; Laue, Hendrik; Olesch, Janine; Schwier, Michael; Sedlaczek, Oliver; Warth, Arne

    2014-03-01

    Much insight into metabolic interactions, tissue growth, and tissue organization can be gained by analyzing differently stained histological serial sections. One opportunity unavailable to classic histology is three-dimensional (3D) examination and computer aided analysis of tissue samples. In this case, registration is needed to reestablish spatial correspondence between adjacent slides that is lost during the sectioning process. Furthermore, the sectioning introduces various distortions like cuts, folding, tearing, and local deformations to the tissue, which need to be corrected in order to exploit the additional information arising from the analysis of neighboring slide images. In this paper we present a novel image registration based method for reconstructing a 3D tissue block implementing a zooming strategy around a user-defined point of interest. We efficiently align consecutive slides at increasingly fine resolution up to cell level. We use a two-step approach, where after a macroscopic, coarse alignment of the slides as preprocessing, a nonlinear, elastic registration is performed to correct local, non-uniform deformations. Being driven by the optimization of the normalized gradient field (NGF) distance measure, our method is suitable for differently stained and thus multi-modal slides. We applied our method to ultra thin serial sections (2 μm) of a human lung tumor. In total 170 slides, stained alternately with four different stains, have been registered. Thorough visual inspection of virtual cuts through the reconstructed block perpendicular to the cutting plane shows accurate alignment of vessels and other tissue structures. This observation is confirmed by a quantitative analysis. Using nonlinear image registration, our method is able to correct locally varying deformations in tissue structures and exceeds the limitations of globally linear transformations.

  7. Confusion over live/dead stainings for the detection of vital microorganisms in oral biofilms--which stain is suitable?

    Science.gov (United States)

    Netuschil, Lutz; Auschill, Thorsten M; Sculean, Anton; Arweiler, Nicole B

    2014-01-11

    There is confusion over the definition of the term "viability state(s)" of microorganisms. "Viability staining" or "vital staining techniques" are used to distinguish live from dead bacteria. These stainings, first established on planctonic bacteria, may have serious shortcomings when applied to multispecies biofilms. Results of staining techniques should be compared with appropriate microbiological data. Many terms describe "vitality states" of microorganisms, however, several of them are misleading. Authors define "viable" as "capable to grow". Accordingly, staining methods are substitutes, since no staining can prove viability.The reliability of a commercial "viability" staining assay (Molecular Probes) is discussed based on the corresponding product information sheet: (I) Staining principle; (II) Concentrations of bacteria; (III) Calculation of live/dead proportions in vitro. Results of the "viability" kit are dependent on the stains' concentration and on their relation to the number of bacteria in the test. Generally this staining system is not suitable for multispecies biofilms, thus incorrect statements have been published by users of this technique.To compare the results of the staining with bacterial parameters appropriate techniques should be selected. The assessment of Colony Forming Units is insufficient, rather the calculation of Plating Efficiency is necessary. Vital fluorescence staining with Fluorescein Diacetate and Ethidium Bromide seems to be the best proven and suitable method in biofilm research.Regarding the mutagenicity of staining components users should be aware that not only Ethidium Bromide might be harmful, but also a variety of other substances of which the toxicity and mutagenicity is not reported. - The nomenclature regarding "viability" and "vitality" should be used carefully.- The manual of the commercial "viability" kit itself points out that the kit is not suitable for natural multispecies biofilm research, as supported by an

  8. Vessel segmentation in screening mammograms

    Science.gov (United States)

    Mordang, J. J.; Karssemeijer, N.

    2015-03-01

    Blood vessels are a major cause of false positives in computer aided detection systems for the detection of breast cancer. Therefore, the purpose of this study is to construct a framework for the segmentation of blood vessels in screening mammograms. The proposed framework is based on supervised learning using a cascade classifier. This cascade classifier consists of several stages where in each stage a GentleBoost classifier is trained on Haar-like features. A total of 30 cases were included in this study. In each image, vessel pixels were annotated by selecting pixels on the centerline of the vessel, control samples were taken by annotating a region without any visible vascular structures. This resulted in a total of 31,000 pixels marked as vascular and over 4 million control pixels. After training, the classifier assigns a vesselness likelihood to the pixels. The proposed framework was compared to three other vessel enhancing methods, i) a vesselness filter, ii) a gaussian derivative filter, and iii) a tubeness filter. The methods were compared in terms of area under the receiver operating characteristics curves, the Az values. The Az value of the cascade approach is 0:85. This is superior to the vesselness, Gaussian, and tubeness methods, with Az values of 0:77, 0:81, and 0:78, respectively. From these results, it can be concluded that our proposed framework is a promising method for the detection of vessels in screening mammograms.

  9. Americium behaviour in plastic vessels

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F.; Herranz, M. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Abelairas, A. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2010-07-15

    The adsorption of {sup 241}Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of {sup 241}Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of {sup 241}Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  10. Americium behaviour in plastic vessels

    International Nuclear Information System (INIS)

    Legarda, F.; Herranz, M.; Idoeta, R.; Abelairas, A.

    2010-01-01

    The adsorption of 241 Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of 241 Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of 241 Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  11. Strategies of fluorescence staining for trace total ribonucleic acid analysis by capillary electrophoresis with argon ion laser-induced fluorescence.

    Science.gov (United States)

    Chung, Yi-An; Chen, Yi-Hsin; Chang, Po-Ling

    2015-08-01

    In this work, five fluorescent dyes (SYTO-9, SYBR Green I, SYBR Green II, SYBR Safe, and SYBR Gold) were used as both on-column and precolumn stains for total RNA analysis by CE-LIF with Ar ion laser excitation. In the on-column RNA stain, the SYTO-9 provided the highest fluorescence intensity and the lowest detectable concentration, as low as 10 pg/μL, while the SYBR Green II and SYBR Gold were adsorbed on the poly(ethylene oxide) thus affected the separation efficiency. As a precolumn stain, SYBR Gold was the most sensitive among the five dyes due to the strong affinity between the dye and RNA molecules. As a result, a single-cell quantity of RNA (10-30 pg per cell) could be detected by CE-LIF with precolumn staining by SYBR Gold. Because of the great savings of fluorescent dye using precolumn stain (one button dye may use for one million stain), this method is the best strategy for RNA staining in terms of cost-effectiveness and sensitivity. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. An automated cell-counting algorithm for fluorescently-stained cells in migration assays

    Directory of Open Access Journals (Sweden)

    Novielli Nicole M

    2011-10-01

    Full Text Available Abstract A cell-counting algorithm, developed in Matlab®, was created to efficiently count migrated fluorescently-stained cells on membranes from migration assays. At each concentration of cells used (10,000, and 100,000 cells, images were acquired at 2.5 ×, 5 ×, and 10 × objective magnifications. Automated cell counts strongly correlated to manual counts (r2 = 0.99, P

  13. [Large vessel vasculitides].

    Science.gov (United States)

    Morović-Vergles, Jadranka; Puksić, Silva; Gracanin, Ana Gudelj

    2013-01-01

    Large vessel vasculitis includes Giant cell arteritis and Takayasu arteritis. Giant cell arteritis is the most common form of vasculitis affect patients aged 50 years or over. The diagnosis should be considered in older patients who present with new onset of headache, visual disturbance, polymyalgia rheumatica and/or fever unknown cause. Glucocorticoides remain the cornerstone of therapy. Takayasu arteritis is a chronic panarteritis of the aorta ant its major branches presenting commonly in young ages. Although all large arteries can be affected, the aorta, subclavian and carotid arteries are most commonly involved. The most common symptoms included upper extremity claudication, hypertension, pain over the carotid arteries (carotidynia), dizziness and visual disturbances. Early diagnosis and treatment has improved the outcome in patients with TA.

  14. Reactor pressure vessel embrittlement

    International Nuclear Information System (INIS)

    1992-07-01

    Within the framework of the IAEA extrabudgetary programme on the Safety of WWER-440/230 NPPs, a list of safety issues requiring broad studies of generic interest have been agreed upon by an Advisory Group who met in Vienna in September 1990. The list was later revised in the light of the programme findings. The information on the status of the issues, and on the amount of work already completed and under way in the various countries, needs to be compiled. Moreover, an evaluation of what further work is required to resolve each one of the issues is also necessary. In view of this, the IAEA has started the preparation of a series of status reports on the various issues. This report on the generic safety issue ''Reactor Pressure Vessel Embrittlement'' presents a comprehensive survey of technical information available in the field and identifies those aspects which require further investigation. 39 refs, 21 figs, 4 tabs

  15. Coronary single vessel disease

    International Nuclear Information System (INIS)

    Kaltenbach, M.; Kober, G.; Satter, P.; Gruentzig, A.; Myler, R.; Sterzer, S.

    1980-01-01

    The seven-years-survival rate is about 80 percent with respect to the most favourable long-time prognosis for coronary single vessel diseases under conservative therapy. In this contribution the control angiography of 76 patients after aorto-coronary bypass operation or transluminal angioplastic is reported. Only two patients subjected to a bypass operation. The recidivity rate is 10 percent after an operation, whereby it is not possible to make a recidivity prognosis. If a recidivity shows up it is being developped during the first three months. If the control angiography three months after the operation shows a good result, then a favourable steady state result can be expected. A comparison of the result with four different centers is given. (APR) [de

  16. Identification of pro-angiogenic markers in blood vessels from stroked-affected brain tissue using laser-capture microdissection

    Directory of Open Access Journals (Sweden)

    Baldellou Maribel

    2009-03-01

    Full Text Available Abstract Background Angiogenesis correlates with patient survival following acute ischaemic stroke, and survival of neurons is greatest in tissue undergoing angiogenesis. Angiogenesis is critical for the development of new microvessels and leads to re-formation of collateral circulation, reperfusion, enhanced neuronal survival and improved recovery. Results Here, we have isolated active (CD105/Flt-1 positive and inactive (CD105/Flt-1 minus (n=5 micro-vessel rich-regions from stroke-affected and contralateral tissue of patients using laser-capture micro-dissection. Areas were compared for pro- and anti-angiogenic gene expression using targeted TaqMan microfluidity cards containing 46 genes and real-time PCR. Further analysis of key gene de-regulation was performed by immunohistochemistry to define localization and expression patterns of identified markers and de novo synthesis by human brain microvessel endothelial cells (HBMEC was examined following oxygen-glucose deprivation (OGD. Our data revealed that seven pro-angiogenic genes were notably up-regulated in CD105 positive microvessel rich regions. These were, beta-catenin, neural cell adhesion molecule (NRCAM, matrix metalloproteinase-2 (MMP-2, tissue inhibitor of matrix metalloproteinase-1 (TIMP-1, hepatocyte growth factor-alpha (HGF-alpha, monocyte chemottractant protein-1 (MCP-1 and and Tie-2 as well as c-kit. Immunohistochemistry demonstrated strong staining of MMP-2, HGF-alpha, MCP-1 and Tie-2 in stroke-associated regions of active remodeling in association with CD105 positive staining. In vitro, OGD stimulated production of Tie-2, MCP-1 and MMP-2 in HBMEC, demonstrated a de novo response to hypoxia. Conclusion In this work we have identified concurrent activation of key angiogenic molecules associated with endothelial cell migration, differentiation and tube-formation, vessel stabilization and stem cell homing mechanisms in areas of revascularization. Therapeutic stimulation of these

  17. Anolyte as an alternative bleach for stained cotton fabrics ...

    African Journals Online (AJOL)

    ... as the two- and three-factor interactions. The results from the study indicated that Anolyte was less effective than sodium hypochlorite as a stain remover for blood, tea, soot/mineral oil and blackcurrant juice. It was noted that the temperature of bleach liquids had an influence on the removal of stains by both bleach liquids.

  18. News from the Biological Stain Commission No. 10

    DEFF Research Database (Denmark)

    Lyon, H O

    2011-01-01

    In the 10th issue of News from the Biological Stain Commission (BSC), under the heading of Regulatory affairs, the Biological Stain Commission's International Affairs Committee presents information from the meeting of ISO/TC 212/WG 1 held in London, UK, on 16-17 November 2009. Furthermore...

  19. News from the Biological Stain Commission no. 12

    DEFF Research Database (Denmark)

    Lyon, H O

    2012-01-01

    In this 12(th) issue of News from the Biological Stain Commission (BSC) under the heading of Regulatory affairs, the Biological Stain Commission's International Affairs Committee presents information from the meetings of ISO/TC 212/WG 1 Quality and competence in the medical laboratory and ISO...

  20. News from the Biological Stain Commission no. 13

    DEFF Research Database (Denmark)

    Lyon, H O

    2013-01-01

    In the 13(th) issue of News from the Biological Stain Commission (BSC) under the heading of Regulatory affairs, the Biological Stain Commission's International Affairs Committee presents information from the first plenary meeting of the International Standards Organization ISO/TC 212 Clinical lab...... laboratory testing and in vitro diagnostic test systems held on 17-19 October 2011 in Las Vegas, Nevada....

  1. Alcian blue-stained particles in a eutrophic lake

    DEFF Research Database (Denmark)

    Worm, J.; Søndergaard, Morten

    1998-01-01

    We used a neutral solution of Alcian Blue to stain transparent particles in eutrophic Lake Frederiksborg Slotss0, Denmark. Alcian Blue-stained particles (ABSP) appeared to be similar to the so-called transparent exopolymer particles (TEP) identified with an acidic solution of Alcian Blue. Our...

  2. Lawsonia inermis And Hibiscus sabdariffa : Posible Histological Stains

    African Journals Online (AJOL)

    The ability of various concentrations of aqueous extracts of Lawsonia inermis and Hibiscus sabdariffa to stain histological tissues was demonstrated. The results with sections of tongue and kidney of the laboratory rat, cut at 6microns thickness showed that only the cellular cytoplasm was stained. However, combinations of ...

  3. The use of special stains in liver biopsy interpretation: Implications ...

    African Journals Online (AJOL)

    Materials and Methods: The formalin fixed paraffin embedded blocks of liver biopsies reported in two histopathology laboratories between 2008 and 2013 were retrieved. These were stained with H and E and the following standard special stains for liver tissue histology – Perl's Prussian blue, reticulin, Sirius red, Shikata ...

  4. anolyte as an alternative bleach for stained cotton fabrics

    African Journals Online (AJOL)

    user

    Serowe College of Education. Private Bag 009. Serowe. Botswana ... and cons that may affect the environment as well as the quality of the final ..... improved as the pH became higher. Effects of anolyte, sodium hypochlorite and distilled water on the removal of tea stain on cotton. Leverette (2013:1) describes a tea stain as a.

  5. Decreased mortality associated with prompt Gram staining of blood cultures.

    Science.gov (United States)

    Barenfanger, Joan; Graham, Donald R; Kolluri, Lavanya; Sangwan, Gaurav; Lawhorn, Jerry; Drake, Cheryl A; Verhulst, Steven J; Peterson, Ryan; Moja, Lauren B; Ertmoed, Matthew M; Moja, Ashley B; Shevlin, Douglas W; Vautrain, Robert; Callahan, Charles D

    2008-12-01

    Gram stains of positive blood cultures are the most important factor influencing appropriate therapy. The sooner appropriate therapy is initiated, the better. Therefore, it is reasonable to expect that the sooner Gram stains are performed, the better. To determine the value of timely Gram stains and whether improvement in Gram stain turnaround time (TAT) is feasible, we compared data for matched pairs of patients with cultures processed promptly ( or =1 hour TAT) and then monitored TAT by control charting.In 99 matched pairs, average difference in time to detection of positive blood cultures within a pair of patients was less than 0.1 hour. For the less than 1 hour TAT group, the average TAT and crude mortality were 0.1 hour and 10.1%, respectively; for the 1 hour or longer TAT group, they were 3.3 hours and 19.2%, respectively (P Gram stains.

  6. Mapping stain distribution in pathology slides using whole slide imaging

    Directory of Open Access Journals (Sweden)

    Fang-Cheng Yeh

    2014-01-01

    Full Text Available Background: Whole slide imaging (WSI offers a novel approach to digitize and review pathology slides, but the voluminous data generated by this technology demand new computational methods for image analysis. Materials and Methods: In this study, we report a method that recognizes stains in WSI data and uses kernel density estimator to calculate the stain density across the digitized pathology slides. The validation study was conducted using a rat model of acute cardiac allograft rejection and another rat model of heart ischemia/reperfusion injury. Immunohistochemistry (IHC was conducted to label ED1 + macrophages in the tissue sections and the stained slides were digitized by a whole slide scanner. The whole slide images were tessellated to enable parallel processing. Pixel-wise stain classification was conducted to classify the IHC stains from those of the background and the density distribution of the identified IHC stains was then calculated by the kernel density estimator. Results: The regression analysis showed a correlation coefficient of 0.8961 between the number of IHC stains counted by our stain recognition algorithm and that by the manual counting, suggesting that our stain recognition algorithm was in good agreement with the manual counting. The density distribution of the IHC stains showed a consistent pattern with those of the cellular magnetic resonance (MR images that detected macrophages labeled by ultrasmall superparamagnetic iron-oxide or micron-sized iron-oxide particles. Conclusions: Our method provides a new imaging modality to facilitate clinical diagnosis. It also provides a way to validate/correlate cellular MRI data used for tracking immune-cell infiltration in cardiac transplant rejection and cardiac ischemic injury.

  7. ITER vacuum vessel dynamic stress analysis of a disruption

    International Nuclear Information System (INIS)

    Riemer, B.W.; Conner, D.L.; Strickler, D.J.; Williamson, D.E.

    1994-01-01

    Dynamic stress analysis of the International Thermonuclear Experimental Reactor vacuum vessel loaded by disruption forces was performed. The deformation and stress results showed strong inertial effects when compared to static analyses. Maximum stress predicted dynamically was 300 MPa, but stress shown by static analysis from loads at the same point in time reached only 80 MPa. The analysis also provided a reaction load history in the vessel's supports which is essential in evaluating support design. The disruption forces were estimated by assuming a 25-MA plasma current decaying at 1 MA/ms while moving vertically. In addition to forces developed within the vessel, vertical loadings from the first wall/strong back assemblies and the divertor were applied to the vessel at their attachment points. The first 50 natural modes were also determined. The first mode's frequency was 6.0 Hz, and its shape is characterized by vertical displacement of the vessel inner leg. The predicted deformation of the vessel appeared similar to its first mode shape combined with radial contraction. Kinetic energy history from the analysis also correlated with the first mode frequency

  8. A sensitive cytochemical staining method for glucose-6-phosphate dehydrogenase activity in individual erythrocytes. I. Optimalization of the staining procedure

    NARCIS (Netherlands)

    van Noorden, C. J.; Vogels, I. M.; James, J.; Tas, J.

    1982-01-01

    A sensitive cytochemical staining method for glucose-6-phosphate dehydrogenase activity in individual human erythrocytes is described. This staining method can be used for the rapid routine discrimination of patients with a deficiency of the enzyme in its homozygote or heterozygote form, but also

  9. Numerical optimization of sequential cryogen spray cooling and laser irradiation for improved therapy of port wine stain.

    Science.gov (United States)

    Milanič, Matija; Jia, Wangcun; Nelson, J Stuart; Majaron, Boris

    2011-02-01

    Despite application of cryogen spray (CS) precooling, customary treatment of port wine stain (PWS) birthmarks with a single laser pulse does not result in complete lesion blanching for a majority of patients. One obvious reason is nonselective absorption by epidermal melanin, which limits the maximal safe radiant exposure. Another possible reason for treatment failure is screening of laser light within large PWS vessels, which prevents uniform heating of the entire vessel lumen. Our aim is to identify the parameters of sequential CS cooling and laser irradiation that will allow optimal photocoagulation of various PWS blood vessels with minimal risk of epidermal thermal damage. Light and heat transport in laser treatment of PWS are simulated using a custom 3D Monte Carlo model and 2D finite element method, respectively. Protein denaturation in blood and skin are calculated using the Arrhenius kinetic model with tissue-specific coefficients. Simulated PWS vessels with diameters of 30-150 µm are located at depths of 200-600 µm, and shading by nearby vessels is accounted for according to PWS histology data from the literature. For moderately pigmented and dark skin phototypes, PWS blood vessel coagulation and epidermal thermal damage are assessed for various parameters of sequential CS cooling and 532-nm laser irradiation, i.e. the number of pulses in a sequence (1-5), repetition rate (7-30 Hz), and radiant exposure. Simulations of PWS treatment in darker skin phototypes indicate specific cooling/irradiation sequences that provide significantly higher efficacy and safety as compared to the customary single-pulse approach across a wide range of PWS blood vessel diameters and depths. The optimal sequences involve three to five laser pulses at repetition rates of 10-15 Hz. Application of the identified cooling/irradiation sequences may offer improved therapeutic outcome for patients with resistant PWS, especially in darker skin phototypes. Copyright © 2011

  10. Novel Process for Laser Stain Removal from Archaeological Oil Paintings

    Science.gov (United States)

    El-Nadi, Lotfia; El-Feky, Osama; Abdellatif, Galila; Darwish, Sawsan

    2013-03-01

    Some samples of oil paintings (5 × 5 cm) were prepared on wooden panel with four types of fungi commonly encountered on oil paintings were selected for this study. Each of the fungi is associated with different colored stains. Fungus Alternaria tenuis is associated by a dense black stain, Chetomium globosum by a brownish gray stain, Aspergillus flavus by a yellowish stain, and Fusaruim oxysporum by a pinkish stain. Fungi growing on oil paintings affect the surface characteristics by forming a variety of colored patches typically composed of many complex chemical substances that are produced during metabolic processes. These colored stains may be encrusted in spores, present in mycelium or secreted to a substance such as oil paintings surfaces. While the fungal stains can sometimes be extracted with appropriate solvents, there are some stains that resist solvent extraction entirely. Developing new solvent system that might attack the paint structure, and is time consuming and requires a great deal of trial and error. Mechanical stain removal is also problematic in that it often produces abrasion of the surface, markedly deteriorating the artwork, and is extra ordinarily fine and tedious. For these reasons, we decided to examine an alternative physical technique as a new approach to deal with stain removal. Since the stains are due to the existence of fungi, we thought it a good idea to remove them by singlet oxygen. We applied the photo dynamic process through which the fungi stains were covered with organic dye derivatives in solution under controlled illumination in the lab. The samples were then irradiated by low power Laser light from a He-Ne laser, the dye will be photodecomposed and produce singlet oxygen. We report in this work the results obtained as a function of: - The concentration and types of the organic dye in solution, - The presence of certain amounts of liquids added to the solution, - The scanning speed of the laser beam on the sample surface

  11. Fluorescent Staining of Tea Pathogenic Fungi in Tea Leaves Using Fluorescein-labeled Lectin

    Science.gov (United States)

    Yamada, Kengo; Yoshida, Katsuyuki; Sonoda, Ryoichi

    Fluorochrome-labeled lectin, fluorescein conjugated wheat germ agglutinin (F-WGA) was applied to stain tea pathogenic fungi in tea leaf tissue. Infected leaves were fixed and decolorized with a mixture of ethanol and acetic acid, and cleared with 10% KOH for whole mount before staining with F-WGA. Hyphae of Pestalotiopsis longiseta, Pseudocercospora ocellata, Botrytis cinerea and Colletotrichum theae-sinensis fluoresced brightly in whole mount and sectioned samples of infected leaf tissue. In browned tissue, hyphae did not fluoresce frequently in whole mount sample. Autofluorescence of leaf tissue was strong in browned tissue of sections, it was removed by 10% KOH treatment before staining. Penetration hyphae of C. theae-sinensis in cell wall of trichome and hyphae in basal part of trichome did not fluoresced frequently. In whole mount samples of tea leaf infected with Exobasidium vexans and E. reticulatum, hymenia appeared on leaf surface fluoresced, but hyphae in leaf tissue did not fluoresce. In sectioned samples, hyphae fluoresced brightly when sections were treated with 10% KOH before staining.

  12. Quantitative gel electrophoresis: new records in precision by elaborated staining and detection protocols.

    Science.gov (United States)

    Deng, Xi; Schröder, Simone; Redweik, Sabine; Wätzig, Hermann

    2011-06-01

    Gel electrophoresis (GE) is a very common analytical technique for proteome research and protein analysis. Despite being developed decades ago, there is still a considerable need to improve its precision. Using the fluorescence of Colloidal Coomassie Blue -stained proteins in near-infrared (NIR), the major error source caused by the unpredictable background staining is strongly reduced. This result was generalized for various types of detectors. Since GE is a multi-step procedure, standardization of every single step is required. After detailed analysis of all steps, the staining and destaining were identified as the major source of the remaining variation. By employing standardized protocols, pooled percent relative standard deviations of 1.2-3.1% for band intensities were achieved for one-dimensional separations in repetitive experiments. The analysis of variance suggests that the same batch of staining solution should be used for gels of one experimental series to minimize day-to-day variation and to obtain high precision. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Pressure vessel for nuclear reactors

    International Nuclear Information System (INIS)

    1975-01-01

    The invention applies to a pressure vessel for nuclear reactors whose shell, made of cast metal segments, has a steel liner. This liner must be constructed to withstand all operational stresses and to be easily repairable. The invention solves this problem by installing the liner at a certain distance from the inner wall of the pressure vessel shell and by filling this clearance with supporting concrete. Both the concrete and the steel liner must have a lower prestress than the pressure vessel shell. In order to avoid damage to the liner when prestressing the pressure vessel shell, special connecting elements are provided which consist of welded-on fastening elements projecting into recesses in the cast metal segments of the pressure vessel. Their design is described in detail. (TK) [de

  14. Rapid staining techniques in cytopathology: a review and comparison of modified protocols for hematoxylin and eosin, Papanicolaou and Romanowsky stains.

    Science.gov (United States)

    Jörundsson, Einar; Lumsden, John H.; Jacobs, Robert M.

    1999-01-01

    The objective of this study was to review and compare rapid protocols for fixation and staining of cytologic smears. We used fresh surgical specimens from dogs and horses to evaluate and modify, if necessary, previously described rapid staining protocols. Slides were wet-fixed, rehydrated or air-dried. Rapid Papanicolaou, hematoxylin and eosin (H&E), and Romanowsky stains were applied, including modification of Diff-Quick stain. The modified rapid staining protocols were simple to use and gave results within 5 minutes that were comparable to those obtained with traditional methods. Advantages of rehydrated vs wet-fixed smears included consistent preparations, a clean background, and equally good or superior nuclear detail.

  15. Effect of Melamine Sponge on Tooth Stain Removal.

    Science.gov (United States)

    Otsuka, Takero; Kawata, Toshitsugu

    2015-01-01

    To investigate the stain removal ability of melamine sponge before aesthetic tooth whitening in extracted teeth. Melamine sponge of thickness 40 mm was compressed and the destruction of the partition wall structure during the compression process was examined under a stereoscopic microscope. An extracted human tooth was cleaned by normal polishing or with melamine sponge for 90 s. To evaluate the stain level, the tooth surfaces were photographed under a stereoscopic microscope at 0, 30, 60 and 90 s. The residual stained region was traced in a high-magnification photograph, and the stain intensity was presented as a change, relative to the intensity before the experiment (0 s). Mechanical cleaning by toothbrushing produced polishing scratches on the tooth surface, whereas use of the melamine sponge resulted in only minimal scratches. As the compression level increased, the stain-removing effect tended to become stronger. Melamine sponge can remove stains from the tooth surface more effectively and less invasively compared to a conventional toothbrush. As no new scratches are made on the tooth surface when using a melamine sponge brush, the risk of re-staining is reduced. Cleaning using a melamine sponge brush can be easily and effectively performed at home and in a dental office.

  16. Microscopic analysis of MTT stained boar sperm cells

    Directory of Open Access Journals (Sweden)

    B.M. van den Berg

    2015-06-01

    Full Text Available The ability of sperm cells to develop colored formazan by reduction of MTT was used earlier to develop a spectrophotometric assay to determine the viability of sperm cells for several mammalian species. It was the objective of the present study to visualize microscopically the location of the formazan in boar sperm cells. The MTT staining process of boar sperm cells can be divided into a series of morphological events. Incubation of the sperm cells in the presence of MTT resulted after a few min in a diffuse staining of the midpiece of the sperm cells. Upon further incubation the staining of the midpiece became more intense, and gradually the formation of packed formazan granules became more visible. At the same time, a small formazan stained granule appeared medially on the sperm head, which increased in size during further incubation. After incubation for about 1 h the midpiece granules were intensely stained and more clearly distinct as granules, while aggregation of sperm cells occurred. Around 90% of the sperm cells showed these staining events. At the end of the staining the formazan granules have disappeared from both the sperm cells and medium, whereas formazan crystals appeared as thin crystal threads, that became heavily aggregated in the incubation medium. It was concluded that formazan is taken up by lipid droplets in the cytoplasm. Further, the use of the MTT assay to test for sperm viability should be regarded as a qualitative assay, whereas its practical use at artificial insemination (AI Stations is limited.

  17. Are there metallic traces in black extrinsic dental stain?

    Science.gov (United States)

    Parnas, Limor; Chevion, Mordechai; Berenshtein, Eduard; Faibis, Sarit; Moskovitz, Moti

    2013-05-01

    The detection of ferric ions in samples of black extrinsic dental stain led to the idea that it is comprised of insoluble ferric compounds. The present study examined the chemical composition of black extrinsic dental stain. Plaque was collected from 17 children with black extrinsic dental stain (study group A) and from 15 children without black extrinsic stain (control group), using sterile graphite curettes; and from 4 children with black extrinsic stain (study group B), using a standard sterile metal curette. Samples were analyzed with a scanning electron microscope (SEM) and subjected to quantitative chemical analysis (energy dispersive spectrometry). Except for calcium and phosphorus levels, no significant differences were found between the chemical composition of black extrinsic dental stain and dental plaque. Metallic ions were not detected in samples collected with a graphite curette (study group A), but were detected in samples collected with a metal curette (study group B). Metallic ions do not seem to be the origin of black extrinsic dental stain. Previous reports of the presence of metallic ions are probably due to contamination of the samples by the collection method.

  18. DNA Comet Giemsa Staining for Conventional Bright-Field Microscopy

    Directory of Open Access Journals (Sweden)

    Andreyan Osipov

    2014-04-01

    Full Text Available This study was undertaken to evaluate the compatibility of Giemsa staining protocol with the comet assay. We showed, for the first time, that DNA comets can be visualized and analyzed using Giemsa staining. We generated DNA damage dose response curves for human peripheral blood lymphocytes exposed to X-ray radiation using the comet assay with either SybrGreen I or Giemsa stain. The dose response curves were fitted by linear regressions (R2 > 0.977. The SybrGreen I results showed only ~1.2-fold higher slope coefficient (method sensitivity compared to the Giemsa results. The unexpectedly high sensitivity of Giemsa staining for the comet assay is due to the Romanowsky-Giemsa effect, the stain photo-stability and the higher resolution of bright-field imaging compared to fluorescence imaging. Our results demonstrate that Giemsa staining can effectively be used for measuring DNA damage by the comet assay. The low cost and availability of Giemsa stain makes this method affordable for any low budget research and will facilitate new applications of the comet assay in biology and medicine.

  19. DNA Comet Giemsa Staining for Conventional Bright-Field Microscopy

    Science.gov (United States)

    Osipov, Andreyan; Arkhangelskaya, Ekaterina; Vinokurov, Alexei; Smetanina, Nadezhda; Zhavoronkov, Alex; Klokov, Dmitry

    2014-01-01

    This study was undertaken to evaluate the compatibility of Giemsa staining protocol with the comet assay. We showed, for the first time, that DNA comets can be visualized and analyzed using Giemsa staining. We generated DNA damage dose response curves for human peripheral blood lymphocytes exposed to X-ray radiation using the comet assay with either SybrGreen I or Giemsa stain. The dose response curves were fitted by linear regressions (R2 > 0.977). The SybrGreen I results showed only ~1.2-fold higher slope coefficient (method sensitivity) compared to the Giemsa results. The unexpectedly high sensitivity of Giemsa staining for the comet assay is due to the Romanowsky-Giemsa effect, the stain photo-stability and the higher resolution of bright-field imaging compared to fluorescence imaging. Our results demonstrate that Giemsa staining can effectively be used for measuring DNA damage by the comet assay. The low cost and availability of Giemsa stain makes this method affordable for any low budget research and will facilitate new applications of the comet assay in biology and medicine. PMID:24727376

  20. A novel washing algorithm for underarm stain removal

    Science.gov (United States)

    Acikgoz Tufan, H.; Gocek, I.; Sahin, U. K.; Erdem, I.

    2017-10-01

    After contacting with human sweat which comprise around 27% sebum, anti-perspirants comprising aluminium chloride or its compounds form a jel-like structure whose solubility in water is very poor. In daily use, this jel-like structure closes sweat pores and hinders wetting of skin by sweat. However, when in contact with garments, they form yellowish stains at the underarm of the garments. These stains are very hard to remove with regular machine washing. In this study, first of all, we focused on understanding and simulating such stain formation on the garments. Two alternative procedures are offered to form jel-like structures. On both procedures, commercially available spray or deo-stick type anti-perspirants, standard acidic and basic sweat solutions and artificial sebum are used to form jel-like structures, and they are applied on fabric in order to get hard stains. Secondly, after simulation of the stain on the fabric, we put our efforts on developing a washing algorithm specifically designed for removal of underarm stains. Eight alternative washing algorithms are offered with varying washing temperature, amounts of detergent, and pre-stain removal procedures. Better algorithm is selected by comparison of Tristimulus Y values after washing.

  1. LANTHANUM STAINING OF THE SURFACE COAT OF CELLS

    Science.gov (United States)

    Shea, Stephen M.

    1971-01-01

    Among the techniques which have been reported to stain the surface coat of cells, for electron microscopy, is lanthanum staining en bloc. Similarly, the presence of the cationic dye, Alcian blue 8GX, in a primary glutaraldehyde fixative has been reported to improve the preservation of the surface coat of cells of many types; however, the preserved coat is not very electron opaque unless thin sections are counterstained. The present paper shows that for several rat tissues lanthanum staining en bloc is an effective electron stain for the cell surface, giving excellent contrast, if combined sequentially with prefixation in an aldehyde fixative containing Alcian blue. The cationic substance cetylpyridinium chloride was found to have a similar effect to that of Alcian blue in enhancing the lanthanum staining of the surface coat material of the brush border of intestinal epithelial cells. The patterns of lanthanum staining obtained for the tissues studied strikingly resemble those reported in the literature where tissues are stained by several standard methods for demonstrating mucosubstances at the ultrastructural level. This fact and the reproduction of the effect of Alcian blue by cetylpyridinium chloride constitute a persuasive empirical argument that the material visualized is a mucopolysaccharide or mucopolysaccharide-protein complex. PMID:4108476

  2. Western Blot of Stained Proteins from Dried Polyacrylamide Gels

    Science.gov (United States)

    Gruber, Claudia; Stan-Lotter, Helga

    1996-01-01

    Western blotting of proteins is customarily performed following their separation on polyacrylamide gels, either prior to staining (1) or, as recently reported, following staining (2). We describe here Western blotting with stained gels, which had been dried and some of which had been stored for years. This procedure permits immunological analysis of proteins, to which antisera may have become available only later, or where the application of newly developed sensitive detection methods is desired. Once rehydration of the gels is achieved, proteins can be-transferred to blotting membranes by any appropriate protocol. Proteins stained with Coomassie Blue have to be detected with a non-chromogenic method, such as the film-based enhanced chemiluminescence (ECL)2) procedure (3). Silver stained proteins, which transfer in the colorless form, may be visualized by any detection method, although, because of the usually very low amounts of proteins, detection by ECL is preferable. Blotting of stained proteins from rehydrated gels is as rapid and as quantitative as from freshly prepared gels, in contrast to blotting from wet stained gels, which requires extensive washing and results in low transfer efficiency (2). Together with a photographic record of the gel pattern, unambiguous identification of immunoreactive proteins from complex mixtures is possible. Some further applications of this work are discussed.

  3. Silver and Cyanine Staining of Oligonucleotides in Polyacrylamide Gel.

    Science.gov (United States)

    Tang, Weizhong; Zhou, Huafu; Li, Wei

    2015-01-01

    To explore why some oligonucleotides in denaturing polyacrylamide gel could not be silver-stained, 134 different oligonucleotides were analyzed using denaturing polyacrylamide gel electrophoresis stained with silver and asymmetric cyanine. As a result, we found that the sensitivity of oligos (dA), (dC), (dG) and (dT) to silver staining could be ranged as (dA) > (dG) > (dC) > (dT) from high to low. It was unexpected that oligo (dT) was hard to be silver-stained. Moreover, the silver staining of an oligonucleotide containing base T could be partially or completely inhibited by base T. The inhibition of silver staining by base T was a competitive inhibition which could be affected by the amounts of the argyrophil nucleobase and base T, the cis-distance between the argyrophil nucleobase and base T, and the gel concentration. The changes of the intensity of an oligonucleotide band caused by the changes of DNA base composition were diverse and interesting. The intensity of some oligonucleotide bands would significantly change when the changes of DNA base composition accumulated to a certain extent (usually ≥ 4 nt). The sensitivity of cyanine staining of ≤ 11-nt long oligonucleotides could be enhanced about 250-fold by fixing the gels with methanol fixing solution.

  4. Containment vessel stability analysis

    International Nuclear Information System (INIS)

    Harstead, G.A.; Morris, N.F.; Unsal, A.I.

    1983-01-01

    The stability analysis for a steel containment shell is presented herein. The containment is a freestanding shell consisting of a vertical cylinder with a hemispherical dome. It is stiffened by large ring stiffeners and relatively small longitudinal stiffeners. The containment vessel is subjected to both static and dynamic loads which can cause buckling. These loads must be combined prior to their use in a stability analysis. The buckling loads were computed with the aid of the ASME Code case N-284 used in conjunction with general purpose computer codes and in-house programs. The equations contained in the Code case were used to compute the knockdown factors due to shell imperfections. After these knockdown factors were applied to the critical stress states determined by freezing the maximum dynamic stresses and combining them with other static stresses, a linear bifurcation analysis was carried out with the aid of the BOSOR4 program. Since the containment shell contained large penetrations, the Code case had to be supplemented by a local buckling analysis of the shell area surrounding the largest penetration. This analysis was carried out with the aid of the NASTRAN program. Although the factor of safety against buckling obtained in this analysis was satisfactory, it is claimed that the use of the Code case knockdown factors are unduly conservative when applied to the analysis of buckling around penetrations. (orig.)

  5. News from the Biological Stain Commission No. 11

    DEFF Research Database (Denmark)

    Lyon, H O; Horobin, R W

    2012-01-01

    The 11th issue of News from the Biological Stain Commission (BSC) provides our first impressions of the REACH and ECHA programs. We intend to give a more thorough account of what these important programs actually mean in later editions of News from the Biological Stain Commission. Under the heading...... of Regulatory Affairs, the Biological Stain Commission's International Affairs Committee presents information from the opening session of the meeting of the International Standards Organization ISO/TC 212 Clinical laboratory testing and in vitro diagnostic test systems held on 2-4 June 2010 in Seoul, Republic...

  6. Strongly Correlated Topological Insulators

    Science.gov (United States)

    2016-02-03

    Strongly Correlated Topological Insulators In the past year, the grant was used for work in the field of topological phases, with emphasis on finding...surface of topological insulators. In the past 3 years, we have started a new direction, that of fractional topological insulators. These are materials...in which a topologically nontrivial quasi-flat band is fractionally filled and then subject to strong interactions. The views, opinions and/or

  7. Measuring vessel dimensions in oak wood (Quercus sp.) on macroscopic level with image analysis system - Lucia G

    OpenAIRE

    Merela, Maks; Oven, Primož; Čufar, Katarina

    2005-01-01

    System for image analysis Lucia G was used for measuring vessel dimensions of oak wood (Quercus sp.) on macroscopic level. We present the problem of sample preparation as well as capturing and processing of images for automatic measurements of diameters, areas and perimeters of early wood vessels. After testing various methods of sample preparation we found out that the best results were obtained when the samples were sanded with paper of granulation 320 and the surface stained with black alc...

  8. Strong Cosmic Censorship

    Science.gov (United States)

    Isenberg, James

    2017-01-01

    The Hawking-Penrose theorems tell us that solutions of Einstein's equations are generally singular, in the sense of the incompleteness of causal geodesics (the paths of physical observers). These singularities might be marked by the blowup of curvature and therefore crushing tidal forces, or by the breakdown of physical determinism. Penrose has conjectured (in his `Strong Cosmic Censorship Conjecture`) that it is generically unbounded curvature that causes singularities, rather than causal breakdown. The verification that ``AVTD behavior'' (marked by the domination of time derivatives over space derivatives) is generically present in a family of solutions has proven to be a useful tool for studying model versions of Strong Cosmic Censorship in that family. I discuss some of the history of Strong Cosmic Censorship, and then discuss what is known about AVTD behavior and Strong Cosmic Censorship in families of solutions defined by varying degrees of isometry, and discuss recent results which we believe will extend this knowledge and provide new support for Strong Cosmic Censorship. I also comment on some of the recent work on ``Weak Null Singularities'', and how this relates to Strong Cosmic Censorship.

  9. Effective isolation of primo vessels in lymph using sound- and ultrasonic-wave stimulation.

    Science.gov (United States)

    Park, Do-Young; Lee, Hye-Rie; Rho, Min-Suk; Lee, Sang-Suk

    2014-12-01

    The effects of stimulation with sound and ultrasonic waves of a specific bandwidth on the microdissection of primo vessels in lymphatic vessels of rabbit were investigated. The primo vessels stained with alcian-blue dye injected in the lymph nodes were definitely visualized and more easily isolated by sound-wave vibration and ultrasonic stimulation applied to rabbits at various frequencies and intensities. With sound wave at 7 Hz and ultrasonic waves at 2 MHz, the probability of detecting the primo vessels was improved to 90%; however, without wave stimulation the probability of discovering primo vessels was about 50% only. Sound and ultrasonic waves at specific frequency bands should be effective for microdissection of the primo vessels in the abdominal lymph of rabbit. We suggest that oscillation of the primo vessels by sound and ultrasonic waves may be useful to visualize specific primo structure, and wave vibration can be a very supportive process for observation and isolation of the primo vessels of rabbits. Copyright © 2014. Published by Elsevier B.V.

  10. BY FRUSTUM CONFINING VESSEL

    Directory of Open Access Journals (Sweden)

    Javad Khazaei

    2016-09-01

    Full Text Available Helical piles are environmentally friendly and economical deep foundations that, due to environmental considerations, are excellent additions to a variety of deep foundation alternatives available to the practitioner. Helical piles performance depends on soil properties, the pile geometry and soil-pile interaction. Helical piles can be a proper alternative in sensitive environmental sites if their bearing capacity is sufficient to support applied loads. The failure capacity of helical piles in this study was measured via an experimental research program that was carried out by Frustum Confining Vessel (FCV. FCV is a frustum chamber by approximately linear increase in vertical and lateral stresses along depth from top to bottom. Due to special geometry and applied bottom pressure, this apparatus is a proper choice to test small model piles which can simulate field stress conditions. Small scale helical piles are made with either single helix or more helixes and installed in fine grained sand with three various densities. Axial loading tests including compression and tension tests were performed to achieve pile ultimate capacity. The results indicate the helical piles behavior depends essentially on pile geometric characteristics, i.e. helix configuration and soil properties. According to the achievements, axial uplift capacity of helical model piles is about equal to usual steel model piles that have the helixes diameter. Helical pile compression bearing capacity is too sufficient to act as a medium pile, thus it can be substituted other piles in special geoenvironmental conditions. The bearing capacity also depends on spacing ratio, S/D, and helixes diameter.

  11. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Hagiwara, Koji; Imura, Yasuya.

    1979-01-01

    Purpose: To provide constituted method for easily performing baking of vacuum vessel, using short-circuiting segments. Constitution: At the time of baking, one turn circuit is formed by the vacuum vessel and short-circuiting segments, and current transformer converting the one turn circuit into a secondary circuit by the primary coil and iron core is formed, and the vacuum vessel is Joule heated by an induction current from the primary coil. After completion of baking, the short-circuiting segments are removed. (Kamimura, M.)

  12. PWR vessel inspection performance improvements

    International Nuclear Information System (INIS)

    Blair Fairbrother, D.; Bodson, Francis

    1998-01-01

    A compact robot for ultrasonic inspection of reactor vessels has been developed that reduces setup logistics and schedule time for mandatory code inspections. Rather than installing a large structure to access the entire weld inspection area from its flange attachment, the compact robot examines welds in overlapping patches from a suction cup anchor to the shell wall. The compact robot size allows two robots to be operated in the vessel simultaneously. This significantly reduces the time required to complete the inspection. Experience to date indicates that time for vessel examinations can be reduced to fewer than four days. (author)

  13. The Gram stain after more than a century.

    Science.gov (United States)

    Popescu, A; Doyle, R J

    1996-05-01

    The Gram stain, the most important stain in microbiology, was described more than a century ago. Only within the past decade, however, has an understanding of its mechanism emerged. It now seems clear that the cell wall of Gram-positive microorganisms is responsible for retention of a crystal violet:iodine complex. In Gram-negative cells, the staining procedures damage the cell surface resulting in loss of dye complexes. Gram-positive microorganisms require a relatively thick cell wall, irrespective of composition, to retain the dye. Therefore, Gram-stainability is a function of the cell wall and is not related to chemistry of cell constituents. This review provides a chronology of the Gram stain and discusses its recently discovered mechanism.

  14. Standardization of the Romanowsky staining procedure: an overview.

    Science.gov (United States)

    Bentley, S A; Marshall, P N; Trobaugh, F E

    1980-01-01

    Commerically available Romanowsky blood stains are variable mixtures of thiazein dyes and brominated fluorescein derivatives with varying degrees of metallic salt contamination in a number of different solvent systems. There is a need for standardized Romanowsky stains of constant composition, which, when used in conjunction with a carefully controlled specimen preparation technique, should give consistent performance. Such a preparation system would be of great value to hematologists in general and would be essential to the validity of data obtained by the digital processing of blood cell images. It is possible to prepare standardized Romanowsky stains as mixtures of two or three dye components, namely, eosin Y, azure B and methylene blue, although azure B has only recently become commercially available at an acceptable degree of purity. The logistic problems of stain standardization are discussed.

  15. The effect of decalcifying solutions on hemosiderin staining.

    Science.gov (United States)

    Byard, Roger W; Bellis, Maria

    2010-09-01

    To determine whether routine decalcification may reduce the amount of stainable iron that is visible on tissue sections, samples of liver and lung tissue with excessive iron stores were placed in three standard decalcifying solutions (i) formic acid [33%], formaldehyde [4%], and NaCl [0.85%]; (ii) formic acid [30%], formaldehyde [4%], and water; and (iii) nitric acid [5%] for 24, 48, 72, and 96 h. After exposure to the decalcifying solutions, the tissues were stained with Perls stain. The slides were examined blind and the intensity of iron staining was scored semiquantitatively from 0 to 3+. The trend in all samples over the course of the experiment (96 h) was for reduction in the intensity of hemosiderin staining. As the amount of stainable hemosiderin in tissues may be significantly altered by decalcification, the absence of hemosiderin in tissues adjacent to a fracture site does not necessarily indicate that the injury was acute. © 2010 American Academy of Forensic Sciences.

  16. The value of intraoperative Gram stain in revision spine surgery.

    Science.gov (United States)

    Shifflett, Grant D; Nwachukwu, Benedict U; Bjerke-Kroll, Benjamin T; Kueper, Janina; Koltsov, Jayme B; Sama, Andrew A; Girardi, Federico P; Cammisa, Frank P; Hughes, Alexander P

    2015-10-01

    Intraoperative cultures and Gram stains are often obtained in cases of revision spine surgery even when clinical signs of infection are not present. The clinical utility and cost-effectiveness of this behavior remain unproven. The aim was to evaluate the clinical utility and cost-effectiveness of routine intraoperative Gram stains in revision spine surgery. This was a retrospective clinical review performed at an academic center in an urban setting. One hundred twenty-nine consecutive adult revision spine surgeries were performed. The outcome measures included intraoperative Gram stains. We retrospectively reviewed the records of 594 consecutive revision spine surgeries performed by four senior surgeons between 2008 and 2013 to identify patients who had operative cultures and Gram stains performed. All revision cases including cervical, thoracic, and lumbar fusion and non-fusion, with and without instrumentation were reviewed. One hundred twenty-nine (21.7%) patients had operative cultures obtained and were included in the study. The most common primary diagnosis code at the time of revision surgery was pseudarthrosis, which was present in 41.9% of cases (54 of 129). Infection was the primary diagnosis in 10.1% (13 of 129) of cases. Operative cultures were obtained in 129 of 595 (21.7%) cases, and 47.3% (61 of 129) were positive. Gram stains were performed in 98 of 129 (76.0%) cases and were positive in 5 of 98 (5.1%) cases. Overall, there was no correlation between revision diagnosis and whether or not a Gram stain was obtained (p=.697). Patients with a history of prior instrumentation were more likely to have a positive Gram stain (pGram staining was found to have a sensitivity of 10.9% (confidence interval [CI] 3.9%-23.6%) and specificity of 100% (CI 93.1%-100%). The positive and negative predictive values were 100% (CI 48.0%-100%) and 57.3% (CI 45.2%-66.2%), respectively. Kappa coefficient was calculated to be 0.1172 (CI 0.0194-0.2151). The cost per discrepant

  17. Design and synthesis of new fluorescent probe for rapid and highly sensitive detection of proteins via electrophoretic gel stain.

    Science.gov (United States)

    Suzuki, Yoshio; Takagi, Nobuyuki; Chimuro, Tomoyuki; Shinohara, Atsushi; Sakaguchi, Nao; Hiratsuka, Atsunori; Yokoyama, Kenji

    2011-06-01

    A new fluorescent molecular probe, 2,2'-(1E,1'E)-2,2'-(4-(dicyanomethylene)-4H-pyrane-2,6-diyl)bis(ethene-2,1-diyl)bis(sodium benzenesulfonate) salt (1), possessing the cyanopyranyl moieties and two benzene sulfonic acid groups was designed and synthesized to detect proteins in solution and for high-throughput SDS-PAGE. Compound 1 exhibited no fluorescence in the absence of proteins; however, it exhibited strong fluorescence on the addition of bovine serum albumin as a result of intramolecular charge transfer. Compared with the conventional protocols for in-gel protein staining, such as SYPRO Ruby and silver staining, 1 achieves higher sensitivity, even though it offers a simplified, higher throughput protocol. In fact, the total time required for protein staining was 60-90 min under optimum conditions much shorter than that required by the less-sensitive silver staining or SYPRO Ruby staining protocols. Moreover, 1 was successfully applied to protein identification by mass spectrometry via in-gel tryptic digestion, Western blotting, and native PAGE together with protein staining by 1, which is a modified protocol of blue native PAGE (BN-PAGE). Thus, 1 may facilitate high-sensitivity protein detection, and it may be widely applicable as a convenient tool in various scientific and medical fields. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. NEONATAL OUTCOME IN MECONIUM STAINED DELIVERIES — A PROSPECTIVE STUDY

    OpenAIRE

    RAMAN, TS RAGHU; JAYAPRAKASH, DG

    1997-01-01

    This prospective study analyzes the neonatal outcome in deliveries complicated by meconium stained amniotic fluid. In a study of 1000 live born deliveries, meconium staining of amniotic fluid was seen in 50 (5%) deliveries. Out of these, 20 newborns (40%) developed classical signs of meconium aspiration syndrome and were managed according to a predetermined protocol. Multiparity, term deliveries, use of sedatives in mother, intrauterine growth retardation and prolonged labour were some of the...

  19. News from the Biological Stain Commission no. 15

    DEFF Research Database (Denmark)

    Lyon, H O; Horobin, R W

    2014-01-01

    In the 15(th) issue of News from the Biological Stain Commission (BSC), under the heading of Regulatory affairs, the Biological Stain Commission's International Affairs Committee presents information from the plenary meetings of the International Standards Organization ISO/TC 212 Clinical laborat...... laboratory testing and in vitro diagnostic test systems held on August 22-24, 2012 in Berlin, Germany. An additional discussion of the use of food dyes in India also is included....

  20. Special enclosure for a pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.; Wedellsborg, U.W.

    1993-01-01

    A pressure vessel enclosure is described comprising a primary pressure vessel, a first pressure vessel containment assembly adapted to enclose said primary pressure vessel and be spaced apart therefrom, a first upper pressure vessel jacket adapted to enclose the upper half of said first pressure vessel containment assembly and be spaced apart therefrom, said upper pressure vessel jacket having an upper rim and a lower rim, each of said rims connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, mean for connecting in a sealable relationship said upper rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, means for connecting in a sealable relationship said lower rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a first lower pressure vessel jacket adapted to enclose the lower half of said first pressure vessel containment assembly and be spaced apart therefrom, said lower pressure vessel jacket having an upper rim connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, and means for connecting in a sealable relationship said upper rim of said first lower pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a second upper pressure vessel jacket adapted to enclose said first upper pressure vessel jacket and be spaced apart therefrom, said second upper pressure vessel jacket having an upper rim and a lower rim, each of said rims adapted to slidably engage the outer surface of said first upper pressure vessel jacket, means for sealing said rims, a second lower pressure vessel jacket adapted to enclose said first lower pressure vessel jacket and be spaced apart therefrom

  1. Artificial Red Blood Cells as Potential Photosensitizers in Dye Laser Treatment Against Port-Wine Stains.

    Science.gov (United States)

    Rikihisa, Naoaki; Watanabe, Shoji; Saito, Yoshiaki; Sakai, Hiromi

    2017-04-13

    We suggest a novel method that uses artificial blood cells (hemoglobin vesicles, Hb-Vs) as photosensitizers in dye laser treatment (at 595-nm wavelength) for port-wine stains (i.e., capillary malformations presenting as red birthmarks) based on the results of animal experiments. As compared with human red blood cells, Hb-Vs have the same absorbance of 595 nm wavelength light and produce the same level of heat following dye laser irradiation. Small sized Hb-Vs (250 nm) distribute in the plasma phase in blood and tend to flow in the marginal zone of microvessels. Intravenous injections of Hb-Vs caused the dilatation of microvessels, and dye laser treatment with Hb-Vs destroyed the vessel wall effectively. Following the intravenous injection of Hb-Vs, the microvessels contained more Hb that absorbed laser photons and produced heat. This extra Hb tended to flow near the endothelial cells, which were the target of the laser treatment. These attributes of Hb-Vs will potentially contribute to enhancing the efficacy of dye laser treatment for port-wine stains. Hemoglobin is a type of porphyrin. Thus, our proposed treatment may have aspects of photodynamic therapy using porphyrin that leads to a cytotoxicity effect by active oxygen.

  2. Lymphatic vessel density and VEGF-C expression as independent predictors of melanoma metastases.

    Science.gov (United States)

    Špirić, Zorica; Eri, Živka; Erić, Mirela

    2017-11-01

    In many patients, the clinical behaviour of cutaneous melanoma is very difficult to predict by traditional histologic and clinical parameters. This study aimed to examine the role of quantitative parameters of tumour lymphangiogenesis and vascular endothelial growth factor (VEGF)-C in predicting metastatic risk in patients with cutaneous melanoma. One hundred melanoma specimens were stained with lymphatic-specific antibody D2-40 and with anti-VEGF-C antibody. Quantitative parameters of lymphangiogenesis-lymphatic vessel density (LVD) and lymphatic vessel area (LVA)-were determined by computer-assisted morphometric analysis. Moderate or strong staining was assessed as a positive expression of VEGF-C in tumour cells. Univariate analysis revealed that intratumoural LVD, peritumoural LVD, VEGF-C expression in tumour cells, melanoma thickness, Clark level, ulceration, gender and histologic type were significant predictors of lymph node metastasis (p = 0.000, p = 0.000, p = 0.000, p = 0.000, p = 0.005, p = 0.005, p = 0.011 and p = 0.027, respectively). No significant association of intratumoural and peritumoural LVA with metastases was found. In multivariate analysis, independent predictors of metastatic risks were melanoma thickness [odds ratio OR = 1.655, 95% confidence interval (CI) 1.102-2.484, p = 0.015], intratumoural LVD (OR = 1.086, 95% CI 1.027-1.148, p = 0.004), peritumoural LVD (OR = 1.050, 95% CI 1.008-1.094, p = 0.020) and a positive VEGF-C expression in tumour cells (OR = 20.337, 95% CI 2.579-160.350, p = 0.004). This study identified intratumoural and peritumoural LVD and the VEGF-C expression in tumour cells as more significant predictors of metastatic risk than melanoma thickness, ulceration and other clinical-pathological parameters. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. An improved method for staining cell colonies in clonogenic assays.

    Science.gov (United States)

    Guda, Kishore; Natale, Leanna; Markowitz, Sanford D

    2007-06-01

    Clonogenic assay is a widely used experimental approach to test for the effects of drugs/genes on the growth and proliferative characteristics of cells in vitro. Accurate quantitation of treatment effects in clonogeneic assays depends on the ability to visualize and count cell colonies precisely. We report a novel method (referred as ETeB) for staining cell colonies grown on plastic and specially coated substrates like collagen. Using colon cancer cell lines grown on plastic and collagen, we compared the colony staining efficiencies of the widely used methylene blue, and Ethidium bromide (ETeB) stains. Results show that the ETeB protocol works well on plastic and is extremely effective for staining colonies on collagen when compared to methylene blue. The key features and advantages of ETeB technique are; (a) reduction in background for colonies grown on collagen and possibly other substrates, (b) the whole procedure takes less than a minute, (c) no post-stain washing step is required which eliminates colony losses for cell lines that are loosely adherent, (d) colony visualization and counting can be done immediately following the staining procedure using a standard UV illuminator and software, and (e) the method works across a wide variety of cell lines. The simplicity and robustness of this procedure should warrant its usage in both small and large-scale clonogenic experiments.

  4. Laser photothermolysis of single blood vessels in the chick chorioallantoic membrane (CAM)

    Science.gov (United States)

    Kimel, Sol; Svaasand, Lars O.; Milner, Thomas E.; Hammer-Wilson, Marie J.; Schell, Michael J.; Nelson, J. Stuart; Berns, Michael W.

    1994-02-01

    Individual blood vessels in the chick chorioallantoic membrane (CAM) were selectively coagulated through photothermolysis, using pulsed laser irradiation at 585 nm. Pulse durations were chosen to be 0.45 ms and 10 ms, which correspond to the thermal relaxation times in blood vessels of 30 micrometers and 150 micrometers diameter, respectively. The dose vs diameter (D vs d) relationship for coagulation was calculated for the two pulse shapes. The energy deposited in a cylindrical absorber of diameter d by an optical field, incident perpendicular to the vessel, was expressed analytically and compared with the energy required to coagulate a blood vessel of the same lumen diameter. When thermal diffusion is incorporated into the model, our findings can be accounted for quantitatively. This information will be of use for improving the laser treatment of port wine stains and other vasculopathies.

  5. Strong Arcwise Connectedness

    OpenAIRE

    Espinoza, Benjamin; Gartside, Paul; Kovan-Bakan, Merve; Mamatelashvili, Ana

    2012-01-01

    A space is `n-strong arc connected' (n-sac) if for any n points in the space there is an arc in the space visiting them in order. A space is omega-strong arc connected (omega-sac) if it is n-sac for all n. We study these properties in finite graphs, regular continua, and rational continua. There are no 4-sac graphs, but there are 3-sac graphs and graphs which are 2-sac but not 3-sac. For every n there is an n-sac regular continuum, but no regular continuum is omega-sac. There is an omega-sac ...

  6. Abortion: Strong's counterexamples fail

    DEFF Research Database (Denmark)

    Di Nucci, Ezio

    2009-01-01

    This paper shows that the counterexamples proposed by Strong in 2008 in the Journal of Medical Ethics to Marquis's argument against abortion fail. Strong's basic idea is that there are cases--for example, terminally ill patients--where killing an adult human being is prima facie seriously morally......'s scenarios have some valuable future or admitted that killing them is not seriously morally wrong. Finally, if "valuable future" is interpreted as referring to objective standards, one ends up with implausible and unpalatable moral claims....

  7. Human Lymphatic Mesenteric Vessels: Morphology and Possible Function of Aminergic and NPY-ergic Nerve Fibers.

    Science.gov (United States)

    D'Andrea, Vito; Panarese, Alessandra; Taurone, Samanta; Coppola, Luigi; Cavallotti, Carlo; Artico, Marco

    2015-09-01

    The lymphatic vessels have been studied in different organs from a morphological to a clinical point of view. Nevertheless, the knowledge of the catecholaminergic control of the lymphatic circulation is still incomplete. The aim of this work is to study the presence and distribution of the catecholaminergic and NPY-ergic nerve fibers in the whole wall of the human mesenteric lymphatic vessels in order to obtain knowledge about their morphology and functional significance. The following experimental procedures were performed: 1) drawing of tissue containing lymphatic vessels; 2) cutting of tissue; 3) staining of tissue; 4) staining of nerve fibers; 5) histofluorescence microscopy for the staining of catecholaminergic nerve fibers; 6) staining of neuropeptide Y like-immune reactivity; 7) biochemical assay of proteins; 8) measurement of noradrenaline; 9) quantitative analysis of images; 10) statistical analysis of data. Numerous nerve fibers run in the wall of lymphatic vessels. Many of them are catecholaminergic in nature. Some nerve fibers are NPY-positive. The biochemical results on noradrenaline amounts are in agreement with morphological results on catecholaminergic nerve fibers. Moreover, the morphometric results, obtained by the quantitative analysis of images and the subsequent statistical analysis of data, confirm all our morphological and biochemical data. The knowledge of the physiological or pathological mechanism regulating the functions of the lymphatic system is incomplete. Nevertheless the catecholaminergic nerve fibers of the human mesenteric lymphatic vessels come from the adrenergic periarterial plexuses of the mesenterial arterial bed. NPY-ergic nerve fibers may modulate the microcirculatory mesenterial bed in different pathological conditions.

  8. Tobacco-stained fingers: a clue for smoking-related disease or harmful alcohol use? A case–control study

    Science.gov (United States)

    John, Gregor; Pasche, Sephora; Rothen, Nicole; Charmoy, Alexia; Delhumeau-Cartier, Cécile; Genné, Daniel

    2013-01-01

    Objective Tobacco stain on fingers is frequent. However, there is scarce description of this clinical sign. We aimed to explore tobacco stain on fingers as a marker of tobacco-related disease independent of cumulative tobacco exposure, and to find behavioural and environmental characteristics associated with those stains. Design Case–control study. Setting A Swiss community hospital of 180 beds. Participants 49 adults presenting tobacco-tars staining on fingers were matched to 49 control smokers by age, gender, height and pack-year (PY). Outcome measures Documented smoking-related carcinoma, ischaemic heart disease, peripheral arterial disease, stroke and chronic obstructive pulmonary disease (COPD), also determined by lung function, were compared between groups. Association between harmful alcohol use, mental disorders or unemployment and tar-staining was adjusted for smoking behaviour through conditional logistic regression. Results Overall cigarette-related disease was high in the case group (84%), and symptomatic peripheral arterial disease was more frequent compared to controls (OR 3.5, CI 95% 1.1 to 14.6). Smoking-related carcinoma, ischaemic heart disease, stroke and COPD were not statistically different for control smokers. Harmful alcohol use was strongly associated with stains and this association persists after adjustment for smoking unfiltered cigarettes, smoking more than one pack of cigarettes in a day and age at smoking onset (adjusted OR 4.6, CI 95% 1.2 to 17.2). Mental disorders and unemployment were not statistically significant. Conclusions Patients with tobacco-tar-stained fingers frequently have cigarette-related disease, however statistically not more than control smokers matched for PY, except for symptomatic peripheral arterial disease. This study suggests a link between stained fingers and addictive behaviour or concomitant high alcohol consumption. PMID:24202054

  9. 2013 East Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  10. SC/OQ Vessel Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Data tables holding information for the Surf Clam/Ocean Quahog vessel and dealer/processor logbooks (negative and positive), as well as individual tag information...

  11. 2013 West Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  12. 2011 Great Lakes Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  13. Targeting Therapy Resistant Tumor Vessels

    National Research Council Canada - National Science Library

    Ruoslahti, Erkki

    2007-01-01

    .... To achieve this, we have developed tumor models for vascular normalization and are using in vivo phage display and isolation of peptides that specifically home to normalized tumor vessels resistant...

  14. Targeting Therapy Resistant Tumor Vessels

    National Research Council Canada - National Science Library

    Ruoslahti, Erkki

    2008-01-01

    .... To achieve this, we have developed tumor models for vascular normalization and are using in vivo phage display and isolation of peptides that specifically home to normalized tumor vessels resistant...

  15. Vessel Permit System Data Set

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — GARFO issues federal fishing permits annually to owners of fishing vessels who fish in the Greater Atlantic region, as required by federal regulation. These permits...

  16. Level indicator for pressure vessels

    Science.gov (United States)

    Not Available

    1982-04-28

    A liquid-level monitor for tracking the level of a coal slurry in a high-pressure vessel including a toroidal-shaped float with magnetically permeable bands thereon disposed within the vessel, two pairs of magnetic-field generators and detectors disposed outside the vessel adjacent the top and bottom thereof and magnetically coupled to the magnetically permeable bands on the float, and signal-processing circuitry for combining signals from the top and bottom detectors for generating a monotonically increasing analog control signal which is a function of liquid level. The control signal may be utilized to operate high-pressure control valves associated with processes in which the high-pressure vessel is used.

  17. Caribbean PR Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch (landed catch) and effort for fishing trips made by vessels fishing in Puerto Rico. The catch and effort data for the entire trip are...

  18. Reactor pressure vessel status report

    International Nuclear Information System (INIS)

    Strosnider, J.; Wichman, K.; Elliot, B.

    1994-12-01

    This report gives a brief description of the reactor pressure vessel (RPV), followed by a discussion of the radiation embrittlement of RPV beltline materials and the two indicators for measuring embrittlement, the end-of-license (EOL) reference temperature and the EOL upper-shelf energy. It also summarizes the GL 92-01 effort and presents, for all 37 boiling water reactor plants and 74 pressurized water reactor plants in the United States, the current status of compliance with regulatory requirements related to ensuring RPV integrity. The staff has evaluated the material data needed to predict neutron embrittlement of the reactor vessel beltline materials. These data will be stored in a computer database entitled the reactor vessel integrity database (RVID). This database will be updated annually to reflect the changes made by the licensees in future submittals and will be used by the NRC staff to assess the issues related to vessel structural integrity

  19. 2013 Great Lakes Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  20. Coastal Discard Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data on the type and amount of marine resources that are discarded or interacted with by vessels that are selected to report to the Southeast...

  1. 2011 East Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  2. A strong comeback

    International Nuclear Information System (INIS)

    Marier, D.

    1992-01-01

    This article presents the results of a financial rankings survey which show a strong economic activity in the independent energy industry. The topics of the article include advisor turnover, overseas banks, and the increase in public offerings. The article identifies the top project finance investors for new projects and restructurings and rankings for lenders

  3. Prosopomorphic vessels from Moesia Superior

    Directory of Open Access Journals (Sweden)

    Nikolić Snežana

    2008-01-01

    Full Text Available The prosopomorphic vessels from Moesia Superior had the form of beakers varying in outline but similar in size. They were wheel-thrown, mould-made or manufactured by using a combination of wheel-throwing and mould-made appliqués. Given that face vessels are considerably scarcer than other kinds of pottery, more than fifty finds from Moesia Superior make an enviable collection. In this and other provinces face vessels have been recovered from military camps, civilian settlements and necropolises, which suggests that they served more than one purpose. It is generally accepted that the faces-masks gave a protective role to the vessels, be it to protect the deceased or the family, their house and possessions. More than forty of all known finds from Moesia Superior come from Viminacium, a half of that number from necropolises. Although tangible evidence is lacking, there must have been several local workshops producing face vessels. The number and technological characteristics of the discovered vessels suggest that one of the workshops is likely to have been at Viminacium, an important pottery-making centre in the second and third centuries.

  4. Intravital two-photon microscopy of immune cell dynamics in corneal lymphatic vessels.

    Directory of Open Access Journals (Sweden)

    Philipp Steven

    Full Text Available BACKGROUND: The role of lymphatic vessels in tissue and organ transplantation as well as in tumor growth and metastasis has drawn great attention in recent years. METHODOLOGY/PRINCIPAL FINDINGS: We now developed a novel method using non-invasive two-photon microscopy to simultaneously visualize and track specifically stained lymphatic vessels and autofluorescent adjacent tissues such as collagen fibrils, blood vessels and immune cells in the mouse model of corneal neovascularization in vivo. The mouse cornea serves as an ideal tissue for this technique due to its easy accessibility and its inducible and modifiable state of pathological hem- and lymphvascularization. Neovascularization was induced by suture placement in corneas of Balb/C mice. Two weeks after treatment, lymphatic vessels were stained intravital by intrastromal injection of a fluorescently labeled LYVE-1 antibody and the corneas were evaluated in vivo by two-photon microscopy (TPM. Intravital TPM was performed at 710 nm and 826 nm excitation wavelengths to detect immunofluorescence and tissue autofluorescence using a custom made animal holder. Corneas were then harvested, fixed and analyzed by histology. Time lapse imaging demonstrated the first in vivo evidence of immune cell migration into lymphatic vessels and luminal transport of individual cells. Cells immigrated within 1-5.5 min into the vessel lumen. Mean velocities of intrastromal corneal immune cells were around 9 µm/min and therefore comparable to those of T-cells and macrophages in other mucosal surfaces. CONCLUSIONS: To our knowledge we here demonstrate for the first time the intravital real-time transmigration of immune cells into lymphatic vessels. Overall this study demonstrates the valuable use of intravital autofluorescence two-photon microscopy in the model of suture-induced corneal vascularizations to study interactions of immune and subsequently tumor cells with lymphatic vessels under close as possible

  5. The influence of Romanowsky-Giemsa type stains on nuclear and cytoplasmic features of cytological specimens.

    Science.gov (United States)

    Schulte, E; Wittekind, D

    1989-04-01

    The aim of the present study was to compare the staining pattern of the standard azure B-eosin Y stain with commercial May-Grünwald-Giemsa (MGG) stains on cytological specimens by means of high resolution image analysis. Several cytological specimens (blood smears, abdominal serous effusions, bronchial scrape material) were air dried, methanol fixed and stained with the standard azure B-eosin Y stain and with commercial May-Grünwald-Giemsa stains. Integrated optical density (IOD) and colour intensities of cell nuclei and cytoplasm were measured with the IBAS 2000 image analyser. Commercial MGG stains gave much higher coefficients of variation for all parameters than the standard stain. Reproducibility of cell nuclei segmentation versus cytoplasm was significantly better for the standard stain. Contamination of the standard stain with methylene blue partly copied the staining pattern of commercial stains. The standard azure B-eosin Y stain is recommended for high resolution image analysis (HRIA) of cytological samples.

  6. Self-assembly of highly fluorescent semiconductor nanorods into large scale smectic liquid crystal structures by coffee stain evaporation dynamics

    International Nuclear Information System (INIS)

    Nobile, Concetta; Carbone, Luigi; Fiore, Angela; Cingolani, Roberto; Manna, Liberato; Krahne, Roman

    2009-01-01

    We deposit droplets of nanorods dispersed in solvents on substrate surfaces and let the solvent evaporate. We find that strong contact line pinning leads to dense nanorod deposition inside coffee stain fringes, where we observe large scale lateral ordering of the nanorods with the long axis of the rods oriented parallel to the contact line. We observe birefringence of these coffee stain fringes by polarized microscopy and we find the direction of the extraordinary refractive index parallel to the long axis of the nanorods.

  7. Ultrastructure of a Mobile Threadlike Tissue Floating in a Lymph Vessel

    Directory of Open Access Journals (Sweden)

    Sharon Jiyoon Jung

    2016-01-01

    Full Text Available Observations of the primo vascular system (PVS floating in lymph ducts were reported by various groups. There have been, however, no studies on the ultrastructure of the entire cross section of a primo vessel (PV inside a lymph vessel with a transmission electron microscope (TEM. In the current study we took the TEM images of a cross section of the PV inside a lymph vessel. We used the Alcian blue staining method for the finding of the target PV in a lymphatic vessel by injecting the dye into the inguinal lymph nodes. The stained PV was harvested together with the lymph vessel and some parts of the specimens were used for studying with optical microscopes. Some other parts were treated according to a standard protocol for TEM. As the results the TEM study revealed the loosely distributed collagen fibers with plenty of empty spaces and the lumens with the endothelial nuclei. It turned out to be very similar to the ultrastructure of the PVs observed on the surfaces of internal organs. It also showed how compactly the PV is surrounded with lymphocytes. In conclusion, the detailed morphological features like the distribution of fibers in the PV were revealed and shown to be similar to another kind of the PV on the surfaces of internal organs.

  8. Strong Electroweak Symmetry Breaking

    CERN Document Server

    Grinstein, Benjamin

    2011-01-01

    Models of spontaneous breaking of electroweak symmetry by a strong interaction do not have fine tuning/hierarchy problem. They are conceptually elegant and use the only mechanism of spontaneous breaking of a gauge symmetry that is known to occur in nature. The simplest model, minimal technicolor with extended technicolor interactions, is appealing because one can calculate by scaling up from QCD. But it is ruled out on many counts: inappropriately low quark and lepton masses (or excessive FCNC), bad electroweak data fits, light scalar and vector states, etc. However, nature may not choose the minimal model and then we are stuck: except possibly through lattice simulations, we are unable to compute and test the models. In the LHC era it therefore makes sense to abandon specific models (of strong EW breaking) and concentrate on generic features that may indicate discovery. The Technicolor Straw Man is not a model but a parametrized search strategy inspired by a remarkable generic feature of walking technicolor,...

  9. Leishman-Giemsa Cocktail - Is it an Effective Stain for Air Dried Cytology Smears.

    Science.gov (United States)

    Doddagowda, Shilpa Manigatta; Shashidhar, Hemalatha Anantharamaiah; Prasad, Chinaiah Subramanyam Babu Rajendra

    2017-03-01

    Air dried cytology smears are stained routinely with Romanowsky stains so that the relative cell size, nuclear size, cytoplasmic details, smear background elements and intercellular matrix components are better appreciated. A variety of modified Romanowsky stains are used in cytology. Leishman-Giemsa (LG) cocktail is one of the new staining techniques which can be used for staining the air dried cytology smears. To evaluate the quality of staining of LG cocktail on air dried smears and to compare the quality of staining of LG cocktail with May Grunwald Giemsa (MGG) which is the most commonly used stain in cytology. The present prospective comparative study was carried out with 100 cases and two extra smears were prepared for each case and stained with MGG and LG cocktail stains. The stained slides were blinded and were evaluated for the staining characteristics of the nucleus, cytoplasm and background staining. Based on this, scoring was done by two pathologists independently. Quality Index (QI) was calculated by dividing the scores obtained with the total score possible. LG cocktail stained slides were excellent in cytoplasmic staining, granularity, nuclear morphology, background material staining and overall staining characteristics. QI of LG cocktail was 0.8 while that of MGG was 0.59. Staining of air dried smears by LG cocktail has a good QI. It is also cheaper, requires short duration for staining as compared to MGG. Hence, LG cocktail can be an effective replacement for MGG for staining the air dried cytology smears.

  10. Plasmons in strong superconductors

    International Nuclear Information System (INIS)

    Baldo, M.; Ducoin, C.

    2011-01-01

    We present a study of the possible plasmon excitations that can occur in systems where strong superconductivity is present. In these systems the plasmon energy is comparable to or smaller than the pairing gap. As a prototype of these systems we consider the proton component of Neutron Star matter just below the crust when electron screening is not taken into account. For the realistic case we consider in detail the different aspects of the elementary excitations when the proton, electron components are considered within the Random-Phase Approximation generalized to the superfluid case, while the influence of the neutron component is considered only at qualitative level. Electron screening plays a major role in modifying the proton spectrum and spectral function. At the same time the electron plasmon is strongly modified and damped by the indirect coupling with the superfluid proton component, even at moderately low values of the gap. The excitation spectrum shows the interplay of the different components and their relevance for each excitation modes. The results are relevant for neutrino physics and thermodynamical processes in neutron stars. If electron screening is neglected, the spectral properties of the proton component show some resemblance with the physical situation in high-T c superconductors, and we briefly discuss similarities and differences in this connection. In a general prospect, the results of the study emphasize the role of Coulomb interaction in strong superconductors.

  11. Superficial and deep blood vessel distribution in the frog telencephalon. Reference to morphological brain asymmetries.

    Science.gov (United States)

    Kemali, M; Sada, E; Fiorino, L

    1990-01-01

    Nine frogs of the species "Rana esculenta" were heart perfused with Microfile Silicone Rubber. The frogs were examined both after dissection (cut with a razor blade) to study the superficial blood vessel pattern, and histologically (the Nissl staining method) to study the distribution of the deep blood capillaries. While the superficial blood vary in pattern, the deep capillaries are distributed symmetrically. This finding does not support a correlation between blood vessel pattern and morphological brain asymmetry, at least in the frog, and thus other explanations must be sought to explain brain asymmetry.

  12. [Immunopathological changes of micro-vessels in dermatomyositis].

    Science.gov (United States)

    Shen, Guang-li; Lü, He; Bi, Hong-yan; Zhang, Wei; Yao, Sheng; Tu, Ping; Yuan, Yun

    2006-07-18

    To investigate the immunopathological changes of micro-vessels in dermatomyositis. Twelve patients with dermatomyositis, 5 males and 7 females, aged 40.8 (6 - 72), underwent muscle biopsy of biceps muscle of arm (n = 11) or deltoid muscle (n = 1). The specimens underwent routine histological, enzyme histochemical, and immunohistochemical staining and microscopy. Ten biopsy specimens from patients with other diseases were used as controls. Perifascicular atrophy of muscular fibers and inflammatory infiltration in perimysium were seen in all patients with dermatomyositis. Non-specific esterase staining showed deep staining of capillaries and micro vascular endothelium among the muscular fibers. Immunohistochemistry showed remarkable reduction of capillaries positive in von Willebrand factor (vWF), thrombomodulin (TM), and endothelial cell nitric oxide synthase (eNOS) in the perifascicular region, and low expression of .eNOS and TM in the microvascular endothelium in the perimysium. The vascular lesions of dermatomyositis are located not only in capillaries, but also in other microvessels. Lower expression of TM and eNOS in vascular endothelium suggests the reduction of anticoagulation and vasodilation functions of vascular endothelium. Dermatomyositis is an inflammatory vascular endothelial disease.

  13. The TPX vacuum vessel and in-vessel components

    International Nuclear Information System (INIS)

    Heitzenroeder, P.; Bialek, J.; Ellis, R.; Kessel, C.; Liew, S.

    1994-01-01

    The Tokamak Physics Experiment (TPX) is a superconducting tokamak with double-null diverters. TPX is designed for 1,000-second discharges with the capability of being upgraded to steady state operation. High neutron yields resulting from the long duration discharges require that special consideration be given to materials and maintainability. A unique feature of the TPX is the use of a low activation, titanium alloy vacuum vessel. Double-wall vessel construction is used since it offers an efficient solution for shielding, bakeout and cooling. Contained within the vacuum vessel are the passive coil system, Plasma Facing Components (PFCs), magnetic diagnostics, and the internal control coils. All PFCs utilize carbon-carbon composites for exposed surfaces

  14. Testing internal coatings in metal vessels

    Science.gov (United States)

    Ruby, A.; Perkins, P.

    1978-01-01

    Presence of pinholes or defects in nonconductive protective coating on inside surface of closed vessel is detected if vessel has one opening into which small stainless-steel probe can be introduced. By inserting probe and attaching another to outside surface, and by filling vessel with ten percent sodium chloride solution, integrity of coating is determined by measuring electrical conductivity through vessel wall.

  15. 46 CFR 119.330 - Pressure vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pressure vessels. 119.330 Section 119.330 Shipping COAST... Machinery § 119.330 Pressure vessels. All unfired pressure vessels must be installed to the satisfaction of the cognizant OCMI. The design, construction, and original testing of such unfired pressure vessels...

  16. 46 CFR 182.330 - Pressure vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Pressure vessels. 182.330 Section 182.330 Shipping COAST...) MACHINERY INSTALLATION Auxiliary Machinery § 182.330 Pressure vessels. All unfired pressure vessels must be... unfired pressure vessels must meet the applicable requirements of subchapter F (Marine Engineering) of...

  17. Photoacoustic determination of blood vessel diameter

    NARCIS (Netherlands)

    Kolkman, R.G.M.; Klaessens, John H.G.M.; Hondebrink, Erwin; Hopman, Jeroen C.W.; de Mul, F.F.M.; Steenbergen, Wiendelt; Thijssen, Johan M.; van Leeuwen, Ton

    2004-01-01

    A double-ring sensor was applied in photoacoustic tomographic imaging of artificial blood vessels as well as blood vessels in a rabbit ear. The peak-topeak time (τ pp) of the laser (1064 nm) induced pressure transient was used to estimate the axial vessel diameter. Comparison with the actual vessel

  18. 46 CFR 169.249 - Pressure vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Pressure vessels. 169.249 Section 169.249 Shipping COAST... and Certification Inspections § 169.249 Pressure vessels. Pressure vessels must meet the requirements of part 54 of this chapter. The inspection procedures for pressure vessels are contained in subpart...

  19. Investigating laser/blood-vessel interaction with color Doppler optical coherence tomography

    Science.gov (United States)

    Barton, Jennifer K.; Izatt, Joseph A.; Welch, Ashley J.

    1998-04-01

    A non-invasive method of imaging laser irradiated blood vessels, and of tracking the healing response, has been achieved using Color Doppler Optical Coherence Tomography (CDOCT). This method may increase understanding of the mechanisms behind treatment of vascular disorders such as port wine stains. The CDOCT system uses a superluminescent diode with a center wavelength of 1280 nm. Pulsed dye and KTP lasers operating at 585 and 532 nm, respectively, were used to irradiate rat and hamster dorsal skin flap window models. The window model is a chronic preparation which exposes subdermal blood vessels while maintaining a thickness of normal skin. Irradiation sites were imaged with CDOCT prior to and immediately after laser irradiation, and at intervals up to several days following irradiation. The CDOCT signal was processed to provide both magnitude and color Doppler images. The Doppler signal provides an estimate of the blood flow velocity. The response of blood vessels to radiant exposures above and below the threshold for vessel coagulation was measured. An increase in the blood vessel backscattered signal was observed as blood and vessel walls were coagulated. Changes in blood flow velocity were noted in cases where vessels constricted or flow became occluded.

  20. Waves and fluid-solid interaction in stented blood vessels

    Science.gov (United States)

    Frecentese, S.; Argani, L. P.; Movchan, A. B.; Movchan, N. V.; Carta, G.; Wall, M. L.

    2018-01-01

    This paper focuses on the modelling of fluid-structure interaction and wave propagation problems in a stented artery. Reflection of waves in blood vessels is well documented in the literature, but it has always been linked to a strong variation in geometry, such as the branching of vessels. The aim of this work is to detect the possibility of wave reflection in a stented artery due to the repetitive pattern of the stents. The investigation of wave propagation and possible blockages under time-harmonic conditions is complemented with numerical simulations in the transient regime.

  1. Molten material-containing vessel

    International Nuclear Information System (INIS)

    Akagawa, Katsuhiko

    1998-01-01

    The molten material-containing vessel of the present invention comprises a vessel main body having an entrance opened at the upper end, a lid for closing the entrance, an outer tube having an upper end disposed at the lower surface of the lid, extended downwardly and having an closed lower end and an inner tube disposed coaxially with the outer tube. When a molten material is charged from the entrance to the inside of the vessel main body of the molten material-containing vessel and the entrance is closed by the lid, the outer tube and the inner tube are buried in the molten material in the vessel main body, accordingly, a fluid having its temperature elevated by absorption of the heat of the molten material rises along the inner circumferential surface of the outer tube, abuts against the lower surface of the lid and cooled by exchanging heat with the lid and forms a circulating flow. Since the heat in the molten material is continuously absorbed by the fluid, transferred to the lid and released from the lid to the atmospheric air, heat releasing efficiency can be improved compared with conventional cases. (N.H.)

  2. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Nagashima, Keisuke; Suzuki, Masaru; Onozuka, Masaki.

    1997-01-01

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  3. A staining protocol for identifying secondary compounds in Myrtaceae1

    Science.gov (United States)

    Retamales, Hernan A.; Scharaschkin, Tanya

    2014-01-01

    • Premise of the study: Here we propose a staining protocol using toluidine blue (TBO) and ruthenium red to reliably identify secondary compounds in the leaves of some species of Myrtaceae. • Methods and Results: Leaves of 10 species representing 10 different genera of Myrtaceae were processed and stained using five different combinations of ruthenium red and TBO. Optimal staining conditions were determined as 1 min of ruthenium red (0.05% aqueous) and 45 s of TBO (0.1% aqueous). Secondary compounds clearly identified under this treatment include mucilage in the mesophyll, polyphenols in the cuticle, lignin in fibers and xylem, tannins and carboxylated polysaccharides in the epidermis, and pectic substances in the primary cell walls. • Conclusions: Potential applications of this protocol include systematic, phytochemical, and ecological investigations in Myrtaceae. It might be applicable to other plant families rich in secondary compounds and could be used as a preliminary screening method for extraction of these elements. PMID:25309840

  4. A staining protocol for identifying secondary compounds in Myrtaceae.

    Science.gov (United States)

    Retamales, Hernan A; Scharaschkin, Tanya

    2014-10-01

    Here we propose a staining protocol using toluidine blue (TBO) and ruthenium red to reliably identify secondary compounds in the leaves of some species of Myrtaceae. • Leaves of 10 species representing 10 different genera of Myrtaceae were processed and stained using five different combinations of ruthenium red and TBO. Optimal staining conditions were determined as 1 min of ruthenium red (0.05% aqueous) and 45 s of TBO (0.1% aqueous). Secondary compounds clearly identified under this treatment include mucilage in the mesophyll, polyphenols in the cuticle, lignin in fibers and xylem, tannins and carboxylated polysaccharides in the epidermis, and pectic substances in the primary cell walls. • Potential applications of this protocol include systematic, phytochemical, and ecological investigations in Myrtaceae. It might be applicable to other plant families rich in secondary compounds and could be used as a preliminary screening method for extraction of these elements.

  5. Sperm viability staining in ecology and evolution: potential pitfalls

    DEFF Research Database (Denmark)

    Holman, Luke

    2009-01-01

    The causes and consequences of variation in sperm quality, survival and ageing are active areas of research in ecology and evolution. In order to address these topics, many recent studies have measured sperm viability using fluorescent staining. Although sperm viability staining has produced...... a number of interesting results, it has some potential pitfalls that have rarely been discussed. In the present paper, I review the major findings of ecology and evolution studies employing sperm viability staining and outline the method's principle limitations. The key problem is that the viability assay...... may itself kill sperm, which is likely to confound many common experimental designs in addition to producing artificially low estimates of sperm viability. I further suggest that sperm number should be routinely measured in sperm viability studies, as it may be an important but overlooked source...

  6. Direct gram stain and urease test to detect Helicobacter pylori.

    Science.gov (United States)

    Van Horn, K G; Dworkin, B M

    1990-01-01

    Antral biopsies were obtained by gastrointestinal endoscopy on 143 adult patients with dyspeptic symptoms of gastritis or peptic ulcer disease. A direct Gram stain and a direct urease test were performed on each biopsy in addition to culture. Forty-three biopsies (30%) were considered positive for Helicobacter pylori based on culture or histologic examination, or both. Thirty-one biopsies (72% sensitivity) were positive for both direct tests, whereas 95 of 100 negative cultures were negative for both tests. Thirty-eight of the 43 positive biopsies were Gram stain positive (sensitivity, 88%; specificity, 100%). The direct urease test alone was positive at 4 hr for 29 biopsies (sensitivity, 67%; specificity, 100%) and at 24 hr for 38 biopsies (sensitivity, 74%; specificity, 95%). Rapid presumptive diagnosis of H. pylori in antral biopsies was obtained when at least one direct test, Gram stain or urease, was positive.

  7. Stain-free histopathology by programmable supercontinuum pulses

    Science.gov (United States)

    Tu, Haohua; Liu, Yuan; Turchinovich, Dmitry; Marjanovic, Marina; Lyngsø, Jens K.; Lægsgaard, Jesper; Chaney, Eric J.; Zhao, Youbo; You, Sixian; Wilson, William L.; Xu, Bingwei; Dantus, Marcos; Boppart, Stephen A.

    2016-08-01

    The preparation, staining, visualization and interpretation of histological images of tissue is well accepted as the gold standard process for the diagnosis of disease. These methods have a long history of development, and are used ubiquitously in pathology, despite being highly time- and labour-intensive. Here, we introduce a unique optical imaging platform and methodology for label-free multimodal multiphoton microscopy that uses a novel photonic-crystal fibre source to generate tailored chemical contrast based on programmable supercontinuum pulses. We demonstrate the collection of optical signatures of the tumour microenvironment, including evidence of mesoscopic biological organization, tumour cell migration and (lymph-) angiogenesis collected directly from fresh ex vivo mammary tissue. Acquisition of these optical signatures and other cellular or extracellular features, which are largely absent from histologically processed and stained tissue, combined with an adaptable platform for optical alignment-free programmable-contrast imaging, offers the potential to translate stain-free molecular histopathology into routine clinical use.

  8. Vital staining of coronal dentin in monkey teeth.

    Science.gov (United States)

    Tronstad, L

    1978-04-01

    Vital staining of monkey incisor teeth with the incisal dentin exposed to the oral environment by attrition was carried out, with the use of a number of dyes (pH and redox indicators). There was a distinct staining of the coronal dentin, regardless of which dye was introduced into the pulpal cavity. The exposed dentin was stained like the unaffected dentin, with the exception of a narrow centrally located zone that extended from the tip of the original pulp horn to the incisal edge of the tooth. The suggestion is that this zone is not unstained because of exposure of the dentin to the oral environment, but because it coincides with an area of the tissue where the pulpal ends of the dentinal tubules are blocked by atubular hard tissue normally laid down in the pulp horn of incisor teeth.

  9. Chromosome-specific staining to detect genetic rearrangements

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Joe W.; Pinkel, Daniel; Tkachuk, Douglas; Westbrook, Carol

    2013-04-09

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyzes. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  10. Evaluation of buffalo semen by Trypan blue/Giemsa staining and related fertility in vitro

    Directory of Open Access Journals (Sweden)

    B. Gasparrini

    2010-02-01

    Full Text Available The aim of this work was to verify the feasibility of an easy, quick double staining technique for evaluation of frozen-thawed semen to predict the fertilizing capability in vitro of buffalo bulls. In Experiment 1, frozen-thawed semen from 6 bulls was stained with double Trypan blue/ Giemsa and the incidence of acrosome-intact live (AIL, acrosome-intact dead (AID, acrosome-lost live (ALL and acrosome-lost dead (ALD sperm was recorded. In Experiment 2, sperm from the same bulls were used to fertilize in vitro matured oocytes. The data obtained confirm that there is a strong “bull effect” in buffalo species, with differences in the percentage of AIL sperm at thawing, in cleavage and blastocyst rates among bulls. Interestingly, it was found that this staining technique can be used for a preliminary screening to select semen to use for IVF, as shown by the correlation existent between the percentages of acrosome-intact viable sperm cells at thawing and the blastocyst yields for 4/6 bulls.

  11. Heterogeneity in Li-Fraumeni families: p53 mutation analysis and immunohistochemical staining.

    OpenAIRE

    MacGeoch, C; Turner, G; Bobrow, L G; Barnes, D M; Bishop, D T; Spurr, N K

    1995-01-01

    We have screened two families for constitutional TP53 mutations, one family with Li-Fraumeni syndrome and the other with features of this syndrome. We report a germline mutation in exon 7 of the TP53 gene in the family with "Li-Fraumeni-like" syndrome. The mutation occurred at codon 245 and causes a Gly-Ser amino acid change. It was inherited by both affected and unaffected subjects. Malignant tumours from all members of this family showed strong positive nuclear immunohistochemical staining ...

  12. Strong-coupling approximations

    International Nuclear Information System (INIS)

    Abbott, R.B.

    1984-03-01

    Standard path-integral techniques such as instanton calculations give good answers for weak-coupling problems, but become unreliable for strong-coupling. Here we consider a method of replacing the original potential by a suitably chosen harmonic oscillator potential. Physically this is motivated by the fact that potential barriers below the level of the ground-state energy of a quantum-mechanical system have little effect. Numerically, results are good, both for quantum-mechanical problems and for massive phi 4 field theory in 1 + 1 dimensions. 9 references, 6 figures

  13. Strong interaction and QFD

    International Nuclear Information System (INIS)

    Ebata, T.

    1981-01-01

    With an assumed weak multiplet structure for bosonic hadrons, which is consistent with the ΔI = 1/2 rule, it is shown that the strong interaction effective hamiltonian is compatible with the weak SU(2) x U(1) gauge transformation. Especially the rho-meson transforms as a triplet under SU(2)sub(w), and this is the origin of the rho-photon analogy. It is also shown that the existence of the non-vanishing Cabibbo angle is a necessary condition for the absence of the exotic hadrons. (orig.)

  14. Intrapartum amnioinfusion for meconium-stained liquor in developing countries.

    Science.gov (United States)

    Moodley, J; Matchaba, P; Payne, A J

    1998-01-01

    Intrapartum amnioinfusion (AI) has been reported to decrease perinatal mortality and morbidity in women with meconium-stained liquor. Such work has not previously been performed at King Edward VIII Hospital (KEH), in a developing country, where the incidence of meconium-stained liquor is said to be extremely high. To establish whether AI during the intrapartum period for meconium-stained liquor decreases Caesarean section rates for fetal distress and decreases perinatal morbidity. Informed consent was obtained from patients in labour who were 3-8 cm dilated, with meconium-staining of the liquor, grades I to III inclusive, and who had a normal cardiotocograph on presentation at term. Sixty patients were included in the trial; 30 had AI. The control group was managed by standard methods. The study group had an amnioinfusion of 0.9% normal saline at 15 ml/min under continuous cardiotocographic monitoring, until a volume of 11 was completed. This was repeated if delivery did not occur within 4 h. The mean pH of umbilical arterial blood was significantly higher in the AI group (7.30 versus 7.23; P = 0.0029). In addition fewer patients in this group developed hypoxic ischaemic encephalopathy (0 versus 2 controls) or meconium aspiration syndrome (1 versus 4 controls). This was not statistically significant. Caesarean section for fetal distress was performed on fewer patients in the AI group (3 versus 7 controls), although this was not statistically significant. These results demonstrate that amnioinfusion is an effective technique for improving the perinatal outcome of pregnancies complicated by meconium-stained liquor in labour. The decrease in Caesarean sections for fetal distress, though not statistically significant in this study, has clinical relevance. Furthermore, this study suggests that amnioinfusion is cost effective in a busy, high-risk labour ward unit and consequently should become standard practice in the management of meconium-stained liquor in labour.

  15. 19 CFR 4.5 - Government vessels.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Government vessels. 4.5 Section 4.5 Customs Duties... VESSELS IN FOREIGN AND DOMESTIC TRADES Arrival and Entry of Vessels § 4.5 Government vessels. (a) No... that is the property of, the U.S. Department of Defense (DoD) will be treated as a Government vessel...

  16. DETECTION OF TISSUE MYCOBACTERIUM TUBERCULOSIS BY DIFFERENTIATING IMMUNOPEROXIDASE STAINING

    Directory of Open Access Journals (Sweden)

    A. P. Lysenko

    2014-01-01

    Full Text Available Staining impression smears from organ and tissues with peroxidase conjugated antibodies to Mycobacterium tuberculosis complex antigens, followed by visualization with diaminobenzidine and Kinyoun stains, ensured the painting of acid-resistant Mycobacterium tuberculosis forms to rubin red, acid-susceptible ones to brown, and tissue cells and microorganisms of other species to blue. Typical bacilli were absent in the lymph nodes of patients and animals with latent infection, but acid-resistant (rubin-red granular forms were encountered in the granulomatous masses. Brown fat cells containing mycobacterial antigens, as well as acid-susceptible granular, reticular, fungoid, and rod-like forms were also found in considerable quantities.

  17. Evaluation Method of Accumulated Cooking Oil Stains in Room

    OpenAIRE

    五十嵐, 由利子; 中村, 和吉; 萬羽, 郁子; Igarashi, Yuriko; Nakamura, Kazuyoshi; Banba, Ikuko

    2005-01-01

    The diffusion of the oil mist while cooking affects the entire room, leaving stains on the ceiling and walls. The validity of measuring the color difference of stains was examined by installing teflon plates in the kitchen and the adjacent space with a view to assessing the oil diffusion. Four houses were designated for the examination. In each house, four teflon plates (20×40mm) were installed on the ceiling and walls of the kitchen and the space adjacent to it. Then, one plate was removed a...

  18. Pressure vessel for nuclear reactors

    International Nuclear Information System (INIS)

    Stoll, A.

    1976-01-01

    The invention relates to a pressure vessel which can be used for nuclear reactors and for chemical processing technologies. A grid of walls welded to each other, which is installed in the interior of the pressure vessel, is so attached to an outer jacket at several edges, that these edges exert a force on the wall of the vessel directed towards the interior. Only the out jacket resists the differential between the inner and outer pressures; the welded walls in the interior do not have to sustain any differential pressure. They create a larger number of inner spaces (or tubes) which can be individually accessible and each of which has a terminal element. (UWI) [de

  19. Emergency venting of pressure vessels

    International Nuclear Information System (INIS)

    Steinkamp, H.

    1995-01-01

    With the numerical codes developed for safety analysis the venting of steam vessel can be simulated. ATHLET especially is able to predict the void fraction depending on the vessel height. Although these codes contain a one-dimensional model they allow the description of complex geometries due to the detailed nodalization of the considered apparatus. In chemical reactors, however, the venting process is not only influenced by the flashing behaviour but additionally by the running chemical reaction in the vessel. Therefore the codes used for modelling have to consider the kinetics of the chemical reaction. Further multi-component systems and dissolving processes have to be regarded. In order to preduct the fluid- and thermodynamic process it could be helpful to use 3-dimensional codes in combination with the one-dimensional codes as used in nuclear industry to get a more detailed describtion of the running processes. (orig./HP)

  20. Strong Coupling Holography

    CERN Document Server

    Dvali, Gia

    2009-01-01

    We show that whenever a 4-dimensional theory with N particle species emerges as a consistent low energy description of a 3-brane embedded in an asymptotically-flat (4+d)-dimensional space, the holographic scale of high-dimensional gravity sets the strong coupling scale of the 4D theory. This connection persists in the limit in which gravity can be consistently decoupled. We demonstrate this effect for orbifold planes, as well as for the solitonic branes and string theoretic D-branes. In all cases the emergence of a 4D strong coupling scale from bulk holography is a persistent phenomenon. The effect turns out to be insensitive even to such extreme deformations of the brane action that seemingly shield 4D theory from the bulk gravity effects. A well understood example of such deformation is given by large 4D Einstein term in the 3-brane action, which is known to suppress the strength of 5D gravity at short distances and change the 5D Newton's law into the four-dimensional one. Nevertheless, we observe that the ...

  1. Limit analysis and design of containment vessels

    International Nuclear Information System (INIS)

    Save, M.

    1984-01-01

    In the introduction, the theory of plastic analysis of shells is briefly recalled. Minimum-volume design for assigned load factor at plastic collapse is then considered and optimality criteria are derived for plates and shells of continuously varying or piecewise-constant thickness. In the first part, containers made of metal are examined. Analytical and numerical limit analysis solutions and corresponding experimental results are considered for various types of vessels, including intersecting shells. Attention is given to experimental post-yield behavior. Some tests up to fracture are discussed. New theoretical and experimental results of limit analysis of stiffened cylindrical vessels are presented, in which reinforcing rings are treated as discrete structural element (no smearing out) and due account is taken of their strong curvature. Cases of collapse by instability under internal pressure are pointed out. Minimum-volume design of circular plates and cylindrical shells is then formulated and various examples are presented of sandwich and solid metal structures. Containers of piecewise-constant thickness are given particular attention. Available experimental evidence on minimum-volume design of plates and shells is reviewed and commented upon. The second part deals with reinforced concrete vessels. Cylindrical containers are studied, from both points of view of limit analysis and of limit design with minimum volume of reinforcement. The practical use of the latter solutions is discussed. A third part reviews other loading cases (including cyclic and impact loads) and gives indications on corresponding theories, formulations and solution methods. The last part is devoted to a discussion of the limitations of the methods presented, within the frame of the 'limit states' design philosophy, which is first briefly recalled. Considerations on further research in the field conclude the paper. (orig.)

  2. 46 CFR 116.1120 - Drainage of cockpit vessels, well deck vessels, and open boats.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Drainage of cockpit vessels, well deck vessels, and open... PASSENGERS CONSTRUCTION AND ARRANGEMENT Drainage and Watertight Integrity of Weather Decks § 116.1120 Drainage of cockpit vessels, well deck vessels, and open boats. Drainage of cockpit vessels, well deck...

  3. Biofilm detection in chronic rhinosinusitis by combined application of hematoxylin-eosin and gram staining.

    Science.gov (United States)

    Tóth, László; Csomor, Péter; Sziklai, István; Karosi, Tamás

    2011-10-01

    The pathomechanism of chronic rhinosinusitis with nasal polyposis (CRS/NP) seems to be unclear. Bacterial-, fungal- and combined biofilms might play a potential role in the pathogenesis of various inflammatory diseases and recently in CRS/NP. A prospective, blinded observational study was performed to confirm that the combination of conventional hematoxylin-eosin (HE) and Gram staining protocols could be used to detect bacterial and fungal biofilms in patients with CRS/NP. A total of 50 patients with CRS/NP undergoing endoscopic sinus surgery (ESS) were analyzed. The negative control group consisted of 12 patients undergoing septoplasty for nasal obstruction without CRS/NP. The nasal polyps and inferior turbinate mucosa specimens applied as negative controls were processed to HE and Gram staining. Biofilm was detected in 44 of 50 patients with CRS/NP and in none of 12 negative controls. In our series, HE method showed an obvious correlation with the results of Gram staining and was allocated to be a good predictor of biofilm existence. It was found that the microscopic structure and thickness of biofilms were strongly associated with the integrity of nasal mucosa and with the characteristics of subepithelial cellular infiltration. This study confirmed the presence of bacterial and fungal biofilms on the surface of NPs obtained from patients with CRS. Since biofilms may affect the severity and recurrence rate of CRS treated by ESS they should be detected histologically. In conclusion, HE staining combined with Gram protocol is a robust and reliable method for the detection of bacterial and fungal biofilms in CRS/NP.

  4. EFFECTS OF THE GRAM STAIN ON MICROSPHERES FROM THERMAL POLYAMINO ACIDS1

    Science.gov (United States)

    Fox, Sidney W.; Yuyama, Shuhei

    1963-01-01

    Fox, Sidney W. (The Florida State University, Tallahassee) and Shuhei Yuyama. Effects of the Gram stain on microspheres from thermal polyamino acids. J. Bacteriol. 85:279–283. 1963.—Microspheres produced from acid proteinoid accept the Gram stain. The stain is negative, but microspheres produced from mixtures containing a sufficient proportion of lysine proteinoid stain positive. Microspheres produced from mixtures containing the appropriate proportions contain individuals which stain positive and others which stain negative. Images PMID:13959050

  5. Stress analysis of pressure vessels

    International Nuclear Information System (INIS)

    Kim, B.K.; Song, D.H.; Son, K.H.; Kim, K.S.; Park, K.B.; Song, H.K.; So, J.Y.

    1979-01-01

    This interim report contains the results of the effort to establish the stress report preparation capability under the research project ''Stress analysis of pressure vessels.'' 1978 was the first year in this effort to lay the foundation through the acquisition of SAP V structural analysis code and a graphic terminal system for improved efficiency of using such code. Software programming work was developed in pre- and post processing, such as graphic presentation of input FEM mesh geometry and output deformation or mode shope patterns, which was proven to be useful when using the FEM computer code. Also, a scheme to apply fracture mechanics concept was developed in fatigue analysis of pressure vessels. (author)

  6. Vessel dilatation in coronary angiograms

    Energy Technology Data Exchange (ETDEWEB)

    Hinterauer, L.; Goebel, N.

    1983-11-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment.

  7. Vessel dilatation in coronary angiograms

    International Nuclear Information System (INIS)

    Hinterauer, L.; Goebel, N.

    1983-01-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment. (orig.) [de

  8. Morin Stain Detects Aluminum-Containing Macrophages in Macrophagic Myofasciitis and Vaccination Granuloma With High Sensitivity and Specificity.

    Science.gov (United States)

    Chkheidze, Rati; Burns, Dennis K; White, Charles L; Castro, Diana; Fuller, Julie; Cai, Chunyu

    2017-04-01

    Macrophagic myofasciitis (MMF) is an inflammatory condition associated with the intramuscular (i.m.) injection of aluminum adjuvant-containing vaccines. It is clinically characterized by myalgia, weakness, and chronic fatigue and histologically by aggregates of cohesive macrophages with abundant basophilic, periodic acid-Schiff (PAS)-positive, diastase-resistant granules that percolate through the peri- and endomysium without eliciting substantial myofiber damage. The definitive diagnosis of MMF requires demonstration of aluminum within these macrophages. We evaluated the Morin stain, a simple, 2-step histochemical stain for aluminum, as a confirmatory diagnostic tool for MMF. Among 2270 muscle biopsies processed at UTSW between 2010 and 2015, a total of 12 MMF cases and 1 subcutaneous vaccination granuloma case were identified (11 pediatric, 2 adults). With the Morin stain, all 13 cases showed strong granular reactivity within the cytoplasm of macrophages but not in myofibers or connective tissue. Three cases of inflammatory myopathy with abundant macrophages (IMAM), 8 cases of granulomatous inflammation and 23 other deltoid muscle biopsies used as controls were all negative. Morin stain could be used in both formalin-fixed paraffin-embedded and cryostat sections. Thus, Morin stain detects aluminum with high sensitivity and specificity in human muscle and soft tissue and may improve the diagnostic yield of MMF and vaccination granuloma. © 2017 American Association of Neuropathologists, Inc.

  9. Axial vessel widening in arborescent monocots.

    Science.gov (United States)

    Petit, Giai; DeClerck, Fabrice A J; Carrer, Marco; Anfodillo, Tommaso

    2014-02-01

    Dicotyledons have evolved a strategy to compensate for the increase in hydraulic resistance to water transport with height growth by widening xylem conduits downwards. In monocots, the accumulation of hydraulic resistance with height should be similar, but the absence of secondary growth represents a strong limitation for the maintenance of xylem hydraulic efficiency during ontogeny. The hydraulic architecture of monocots has been studied but it is unclear how monocots arrange their axial vascular structure during ontogeny to compensate for increases in height. We measured the vessel lumina and estimated the hydraulic diameter (Dh) at different heights along the stem of two arborescent monocots, Bactris gasipaes (Kunth) and Guadua angustifolia (Kunth). For the former, we also estimated the variation in Dh along the leaf rachis. Hydraulic diameter increased basally from the stem apex to the base with a scaling exponent (b) in the range of those reported for dicot trees (b = 0.22 in B. gasipaes; b = 0.31 and 0.23 in G. angustifolia). In B. gasipaes, vessels decrease in Dh from the stem's centre towards the periphery, an opposite pattern compared with dicot trees. Along the leaf rachis, a pattern of increasing Dh basally was also found (b = 0.13). The hydraulic design of the monocots studied revealed an axial pattern of xylem conduits similar to those evolved by dicots to compensate and minimize the negative effect of root-to-leaf length on hydrodynamic resistance to water flow.

  10. LIGO: The strong belief

    CERN Multimedia

    Antonella Del Rosso

    2016-01-01

    Twenty years of designing, building and testing a number of innovative technologies, with the strong belief that the endeavour would lead to a historic breakthrough. The Bulletin publishes an abstract of the Courier’s interview with Barry Barish, one of the founding fathers of LIGO.   The plots show the signals of gravitational waves detected by the twin LIGO observatories at Livingston, Louisiana, and Hanford, Washington. (Image: Caltech/MIT/LIGO Lab) On 11 February, the Laser Interferometer Gravitational-Wave Observatory (LIGO) and Virgo collaborations published a historic paper in which they showed a gravitational signal emitted by the merger of two black holes. These results come after 20 years of hard work by a large collaboration of scientists operating the two LIGO observatories in the US. Barry Barish, Linde Professor of Physics, Emeritus at the California Institute of Technology and former Director of the Global Design Effort for the Internat...

  11. Comparative assessment of seller's staining test (SST) and direct ...

    African Journals Online (AJOL)

    Conclusion:The relatively low sensitivity of the SST observed in this study calls for its replacement with the dFAT for accurate ... seller's staining test (SST) and direct fluorescent antibody test for rapid and accurate laboratory diagnosis of rabies. Afri Health Sci. 2016 ... lack of laboratory equipment and reliable reagents16,17.

  12. Interlaboratory variability of Ki67 staining in breast cancer.

    Science.gov (United States)

    Focke, Cornelia M; Bürger, Horst; van Diest, Paul J; Finsterbusch, Kai; Gläser, Doreen; Korsching, Eberhard; Decker, Thomas

    2017-10-01

    Postanalytic issues of Ki67 assessment in breast cancers like counting method standardisation and interrater bias have been subject of various studies, but little is known about analytic variability of Ki67 staining between pathology labs. Our aim was to study interlaboratory variability of Ki67 staining in breast cancer using tissue microarrays (TMAs) and central assessment to minimise preanalytic and postanalytic influences. Thirty European pathology labs stained serial slides of a TMA set of breast cancer tissues with Ki67 according to their routine in-house protocol. The Ki67-labelling index (Ki67-LI) of 70 matched samples was centrally assessed by one observer who counted all cancer cells per sample. We then tested for differences between the labs in Ki67-LI medians by analysing variance on ranks and in proportions of tumours classified as luminal A after dichotomising oestrogen receptor-positive cancers into cancers showing low (Ki67-LI using Cochran's Q. Substantial differences between the 30 labs were indicated for median Ki67-LI (0.65%-33.0%, p cancers classified as luminal A (17%-57%, p Ki67 staining of breast cancer tissue was found between 30 routine pathology labs. Clinical use of the Ki67-LI for therapeutic decisions should be considered only fully aware of lab-specific reference values. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Comparative assessment of seller's staining test (SST) and direct ...

    African Journals Online (AJOL)

    Background: Rabies causes 55, 000 annual human deaths globally and about 10,000 people are exposed annually in Nigeria. Diagnosis of animal rabies in most African countries has been by direct microscopic examination. In Nigeria, the Seller's stain test (SST) was employed until 2009. Before then, both SST and dFAT ...

  14. The gram stain smear: A screening test for genital mycoplasmas ...

    African Journals Online (AJOL)

    Result of 168 vaginal specimens from women examined for genital mycoplasmas showed that more of these organisms were isolated from specimens whose Gram stain smears were devoid of Gram positive bacilli (GPB) (43%) as against those whose smears contain GPB (22.1%). This result was found to be statistically ...

  15. Gram's Stain Does Not Cross the Bacterial Cytoplasmic Membrane.

    Science.gov (United States)

    Wilhelm, Michael J; Sheffield, Joel B; Sharifian Gh, Mohammad; Wu, Yajing; Spahr, Christian; Gonella, Grazia; Xu, Bolei; Dai, Hai-Lung

    2015-07-17

    For well over a century, Hans Christian Gram's famous staining protocol has been the standard go-to diagnostic for characterizing unknown bacteria. Despite continuous and ubiquitous use, we now demonstrate that the current understanding of the molecular mechanism for this differential stain is largely incorrect. Using the fully complementary time-resolved methods: second-harmonic light-scattering and bright-field transmission microscopy, we present a real-time and membrane specific quantitative characterization of the bacterial uptake of crystal-violet (CV), the dye used in Gram's protocol. Our observations contradict the currently accepted mechanism which depicts that, for both Gram-negative and Gram-positive bacteria, CV readily traverses the peptidoglycan mesh (PM) and cytoplasmic membrane (CM) before equilibrating within the cytosol. We find that not only is CV unable to traverse the CM but, on the time-scale of the Gram-stain procedure, CV is kinetically trapped within the PM. Our results indicate that CV, rather than dyes which rapidly traverse the PM, is uniquely suited as the Gram stain.

  16. A comparision of modified and standard papanicolaou staining ...

    African Journals Online (AJOL)

    Objective: To compare modified and standard Papanicolaou (Pap) staining methods in the assessment of the cervical smears. Design: A descriptive cross sectional study. setting: Kenyatta National Hospital. Subjects: One hundred and sixty two women who were eligible for a pap smear and met the inclusion criteria.

  17. News from the Biological Stain Commission No. 14

    DEFF Research Database (Denmark)

    Lyon, Hans O

    2013-01-01

    In the 14(th) issue of News from the Biological Stain Commission (BSC) the BSC's International Affairs Committee presents information from the meetings of ISO/TC 212/WG 3, In vitro diagnostic products, and from the final plenary meeting of ISO/TC 212, Clinical laboratory testing and in vitro...

  18. News from the Biological Stain Commission No. 5

    DEFF Research Database (Denmark)

    Lyon, H O; Dapson, R W

    2009-01-01

    In this fifth issue of News from the Biological Stain Commission (BSC), under the heading of Regulatory Affairs, the BSC's International Affairs Committee provides more information from the meeting of the International Standards Organization ISO/TC 212 Committee that took place on June 2-4, 2008...

  19. Comparison of Giemsa Staining, Intraperitoneal Injection and Oral

    Directory of Open Access Journals (Sweden)

    Sajad Rashidi

    2014-02-01

    Full Text Available Background: Toxoplasma gondii is one of the most common protozoan parasites in humans and animals in all countries of the world. The aim of this study was to detect Toxoplasma parasite in the brain of wild rats in Tehran using smear preparation, Giemsa staining, Intraperitoneal injection and oral administration to Souri mice. Materials and Methods: Forty rats were collected from different areas of Tehran. Smears were prepared from rat brains on glass slides and stained using Giemsa. In the second method, a cell suspension was prepared from rat brain and was given orally and injected intraperitoneally into Souri mice. In peritoneal method, peritoneum of the mice was examined for parasites. In oral method, the titer of Toxoplasma antibody in sera of Souri mice was determined using Toxoplasma IgG antibody kit and anti-mouse conjugate of Sigma company. Results: All results were negative in Giemsa staining method. In the second method, the results were negative and no parasites were observed in peritoneum of Souri mice. In oral administration method, after ingestion of suspensions by Souri mice and measuring the IgG titer, 50% of them showed a positive titer after one month. Conclusion: In detection of Toxoplasma gondii, the method of smear preparation on glass slides followed by Giemsa staining, and intraperitoneal injection of brain suspensions to Souri mice are of less value in comparison with oral administration of suspensions and determining the titer of IgG in sera of Souri mice.

  20. a comparison of modified and standard papanicolaou staining ...

    African Journals Online (AJOL)

    2011-07-07

    Jul 7, 2011 ... Corporation, Hollywood, Florida Gynecologic. Seminars in Surgical Oncology 1999; 16: 217–221. Gupta, S., Chachra, K. L., Bhadola, P. 7. et al. Modified. Papanicolaou staining protocol with minimum alcohol use: a cost-cutting measure for resource limited. Division of Cytopathology, Institute of Cytology ...

  1. Microscopic analysis of MTT stained boar sperm cells

    African Journals Online (AJOL)

    tulyasys

    2015-06-08

    Jun 8, 2015 ... Microscopic analysis of MTT stained boar sperm cells. B.M. van den Berg*. Barex Biochemical Products, Seb. Centenweg 45, 1602ML Enkhuizen, The Netherlands. Abstract. The ability of sperm cells to develop colored formazan by reduction of MTT was used earlier to develop a spectrophotometric.

  2. Amalgam stained dentin: a proper substrate for bonding resin composite?

    NARCIS (Netherlands)

    Scholtanus, J.D.

    2016-01-01

    Nowadays the use of dental amalgam is mostly abandoned and substituted by tooth colored resin composites that can be bonded to teeth tissues by adhesive techniques. The aim of this thesis was to find out whether dark stained dentin, as often observed after removal of amalgam restorations and

  3. The Stained Glass Paintings of Nigeria's Prime Artists, YCA Grillo

    African Journals Online (AJOL)

    Nneka Umera-Okeke

    Abstract. Many lamps same Light' investigates the place of agency in the transmutation of indigenous imageries in the art works of the pictorial turn. Through an investigation that entailed an empirical analysis of the works of two Nigerian prime stained glass artists, Yusuf Grillo and David Dale, this study established that in ...

  4. Borax methylene blue: a spectroscopic and staining study.

    Science.gov (United States)

    Donaldson, P T; Russo, A; Reynolds, C; Lillie, R D

    1978-07-01

    Borax methylene blue is quite stable at room temperatures of 22-25 C. At 30 C polychroming is slow; during 50 days in a water bath at this temperature the absorption peak moves from 665 to 656 nm. At 35 C, the absorption peak reaches 660 nm in 7 days, 654 nm in 14. At 60 C polychroming is rapid, the absorption peak reaching 640-620 nm in 3 days. When the pH of the borax methylene blue solutions, normally about 9.0, is adjusted to pH 6.5, the absorption peak remains at 665 nm even when incubated at 60 C for extended periods. When used as a blood stain 0.4 ml borax methylene blue (1% methylene blue in 1% borax), 4 ml acetone, 2 ml borax-acid phosphate buffer to bring the solution to pH 6.5, and distilled water to make 40 ml, with 0.2 ml 1% eosin added just before using, an excellent Nocht-Giemsa type stain is achieved after 30 minutes staining. The material plasmodia P. falciparum, P. vivax, and P. berghei stain moderate blue with dark red chromatin and green to black pigment granules. The study confirms Malachowski's 1891 results and explains Gautier's 1896-98 failure to duplicate it.

  5. Christendom's Narratives and the Stained Glass Designs of Yusuf ...

    African Journals Online (AJOL)

    This paper attempts a recast of Christendom's narratives in the stained glass designs of Yusuf Cameron Adebayo Grillo as the distinctive overarching mechanism of the evangelisation paradigm of the post Vatican II Church. It, therefore, draws attention to the delimitation of time frames in the history of the art form. Using the ...

  6. A generally applicable sequential alkaline phosphatase immunohistochemical double staining

    NARCIS (Netherlands)

    van der Loos, Chris M.; Teeling, Peter

    2008-01-01

    A universal type of sequential double alkaline phosphatase immunohistochemical staining is described that can be used for formalin-fixed, paraffin-embedded and cryostat tissue sections from human and mouse origin. It consists of two alkaline phosphatase detection systems including enzymatic

  7. Color and dichroism of silver-stained glasses

    International Nuclear Information System (INIS)

    Molina, Gloria; Murcia, Sonia; Molera, Judit; Roldan, Clodoaldo; Crespo, Daniel; Pradell, Trinitat

    2013-01-01

    Yellow decorations in glasses have been produced since the beginning of the fourteenth century by incorporating metallic silver nanoparticles into the glass (from a few to some tens of nanometers). The optical response of the glass-particles composite is determined by the surface plasmon resonance absorption and scattering of the nanometric metallic particles. Generally, the same color is perceived in reflection and in transmission although dichroic effects are occasionally observed. As silver-stained glasses were designed to be observed in transmission, tuning the transmission color from yellow to red was of technological interest. The relationship between the color observed both in transmission and reflection and the composition and nanostructure of regular (yellow) and dichroic (yellow and red) silver stains from the Renaissance (late fifteenth and sixteenth century, respectively) is related to the presence of a layer (of about 10–20 μm thick) of metallic silver nanoparticles (from few to 100 nm in size). The correlation between the colors observed and the silver stain nanostructure is studied with particular emphasis on the origin of the dichroic behavior. The optical response is computed and compared to the experimental data. Differences in the synthesis parameters responsible for the colors and for the dichroic behavior of the silver stain glasses are proposed. This is essential for the replication of the glass pieces which are required as replacements in the restoration/conservation of the windows but is also of broader interest

  8. [Pnemocystis jiroveci pneumonia: Comparison between conventional PCR and staining techniques].

    Science.gov (United States)

    Kaouech, E; Kallel, K; Anane, S; Belhadj, S; Abdellatif, S; Mnif, K; Ben Othmane, T; Ben Lakhal, S; Kilani, B; Ben Châabane, T; Chaker, E

    2009-07-01

    Diagnosis of pneumocystis pneumonia is usually based on clinical features and X-rays photography and confirmed in the laboratory by visualisation of Pneumocystis organisms in stained preparations of respiratory specimens using several techniques (Gomori-Grocott, May-Grünwald Giemsa, bleu de toluidine O). Actually, PCR has considerably increased sensitivity of detection of Pneumocystis. The aim of this study is to compare conventional PCR results to those of staining techniques (Gomori-Grocott, May-Grünwald Giemsa) in addition to the X-ray and clinical findings in order to evaluate the contribution of each method. Sixty-four respiratory specimens were collected from 54 immuno-compromised patients with clinical symptoms of pulmonary infection. We diagnosed pneumocystis pneumonia in 16 patients according to staining techniques and/or typical clinical and radiological findings and/or response to treatment. Of the 15 patients, 14 were positive by PCR and only five were positive by direct examination, yielding a sensitivity and specificity of 93.3 and 87.1% for PCR and 33.3 and 100% for staining techniques. Conventional PCR provides a sensitive and objective method for the detection Pneumocystis jiroveci from less invasive sample.

  9. Black stain and dental caries in Filipino schoolchildren.

    NARCIS (Netherlands)

    Heinrich-Weltzien, R.; Monse, B.; Palenstein Helderman, W.H. van

    2009-01-01

    Black stain is defined as dark pigmented exogenous substance in lines or dots parallel to the gingival margin and firmly adherent to the enamel at the cervical third of the tooth crowns in the primary and permanent dentition. OBJECTIVES: This study was conducted to assess the prevalence of black

  10. Meconium-stained amniotic fluid – what is the evidence ...

    African Journals Online (AJOL)

    Opinions regarding the significance of meconium-stained liquor detected during labour have varied although there is consensus that meconium aspirated into the lungs of the neonate may lead to meconium aspiration syndrome. The efficacy of various interventions designed to prevent meconium aspiration syndrome are ...

  11. Image analysis of dye stained patterns in soils

    Science.gov (United States)

    Bogner, Christina; Trancón y Widemann, Baltasar; Lange, Holger

    2013-04-01

    Quality of surface water and groundwater is directly affected by flow processes in the unsaturated zone. In general, it is difficult to measure or model water flow. Indeed, parametrization of hydrological models is problematic and often no unique solution exists. To visualise flow patterns in soils directly dye tracer studies can be done. These experiments provide images of stained soil profiles and their evaluation demands knowledge in hydrology as well as in image analysis and statistics. First, these photographs are converted to binary images classifying the pixels in dye stained and non-stained ones. Then, some feature extraction is necessary to discern relevant hydrological information. In our study we propose to use several index functions to extract different (ideally complementary) features. We associate each image row with a feature vector (i.e. a certain number of image function values) and use these features to cluster the image rows to identify similar image areas. Because images of stained profiles might have different reasonable clusterings, we calculate multiple consensus clusterings. An expert can explore these different solutions and base his/her interpretation of predominant flow mechanisms on quantitative (objective) criteria. The complete workflow from reading-in binary images to final clusterings has been implemented in the free R system, a language and environment for statistical computing. The calculation of image indices is part of our own package Indigo, manipulation of binary images, clustering and visualization of results are done using either build-in facilities in R, additional R packages or the LATEX system.

  12. Comparison of various staining techniques in the diagnosis of ...

    African Journals Online (AJOL)

    There was a significant moderate level of agreement between the staining methods though trichrome showed a stronger agreement than auramine when compared with Modified ZN in test (κ value 0.569 and 0.553 respectively), and a significant, fair level of agreement between the methods with Auramine showing a ...

  13. Comparism of Various Staining Techniques in the Diagnosis of ...

    African Journals Online (AJOL)

    SITWALA COMPUTERS

    value of 69.9%, negative predictive value of 85.2% in test subjects. There was a significant moderate level of agreement between the staining methods though. Trichrome showed a stronger agreement than Auramine when compared with Modified ZN in test (к value 0.569 and 0.553 respectively), and a significant, fair level ...

  14. Standardization in biological staining. The influence of dye manufacturing

    DEFF Research Database (Denmark)

    Lyon, H

    2000-01-01

    The purpose of biological staining is to obtain specimens of biological material that can be assessed in the microscope. These specimens are influenced by all processes from removal from the intact organism to mounting on the microscopic slide. To achieve comparable results with various techniques...

  15. Interlaboratory variability of Ki67 staining in breast cancer

    NARCIS (Netherlands)

    Focke, Cornelia M.; Bürger, Horst; van Diest, Paul J.; Finsterbusch, Kai; Gläser, Doreen; Korsching, Eberhard; Decker, Thomas; Anders, M.; Bollmann, R.; Eiting, Fr; Friedrich, K.; Habeck, J. O.; Haroske, G.; Hinrichs, B.; Behrens, A.; Krause, Lars Udo; Braun-Lang, U.; Lorenzen, J.; Minew, N.; Mlynek-Kersjes, M.; Nenning, H.; Packeisen, J.; Poche-de Vos, F.; Reyher-Klein, S.; Rothacker, D.; Schultz, M.; Sturm, U.; Tawfik, M.; Berghäuser, K. H.; Böcker, W; Cserni, G.; Habedank, S.; Lax, S.; Moinfar, F.; Regitnig, P.; Reiner-Concin, A.; Rüschoff, J.; Varga, Z.; Woziwodski, J.

    2017-01-01

    Background Postanalytic issues of Ki67 assessment in breast cancers like counting method standardisation and interrater bias have been subject of various studies, but little is known about analytic variability of Ki67 staining between pathology labs. Our aim was to study interlaboratory variability

  16. Structural analysis of the JT-60SA cryostat vessel body

    Energy Technology Data Exchange (ETDEWEB)

    Botija, José, E-mail: jose.botija@ciemat.es [Association EURATOM – CIEMAT, Avda. Complutense 40, 28040 Madrid (Spain); Alonso, Javier; Fernández, Pilar; Medrano, Mercedes; Ramos, Francisco; Rincon, Esther; Soleto, Alfonso [Association EURATOM – CIEMAT, Avda. Complutense 40, 28040 Madrid (Spain); Davis, Sam; Di Pietro, Enrico; Tomarchio, Valerio [Fusion for Energy, JT-60SA European Home Team, 85748 Garching bei Munchen (Germany); Masaki, Kei; Sakasai, Akira; Shibama, Yusuke [JAEA – Japan Atomic Energy Agency, Naka Fusion Institute, Ibaraki 311-0193 (Japan)

    2013-10-15

    Highlights: ► Structural analysis to validate the JT-60SA cryostat vessel body design. ► Design code ASME 2007 “Boiler and Pressure Vessel Code. Section VIII”. ► First buckling mode: load multiplier of 10.644, higher than the minimum factor 4.7. ► Elastic and elastic–plastic stress analysis meets ASME against plastic collapse. ► Bolted fasteners have been analyzed showing small gaps closed by strong welding. -- Abstract: The JT-60SA cryostat is a stainless steel vacuum vessel (14 m diameter, 16 m height) which encloses the Tokamak providing the vacuum environment (10{sup −3} Pa) necessary to limit the transmission of thermal loads to the components at cryogenic temperature. It must withstand both external atmospheric pressure during normal operation and internal overpressure in case of an accident. The paper summarizes the structural analyses performed in order to validate the JT-60SA cryostat vessel body design. It comprises several analyses: a buckling analysis to demonstrate stability under the external pressure; an elastic and an elastic–plastic stress analysis according to ASME VIII rules, to evaluate resistance to plastic collapse including localized stress concentrations; and, finally, a detailed analysis with bolted fasteners in order to evaluate the behavior of the flanges, assuring the integrity of the vacuum sealing welds of the cryostat vessel body.

  17. Commercial Passenger Fishing Vessel Fishery

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains the logbook data from U.S.A. Commercial Passenger Fishing Vessels (CPFV) fishing in the U.S.A. EEZ and in waters off of Baja California, from...

  18. The Vessel Schedule Recovery Problem

    DEFF Research Database (Denmark)

    Brouer, Berit Dangaard; Plum, Christian Edinger Munk; Vaaben, Bo

    Maritime transportation is the backbone of world trade and is accountable for around 3% of the worlds CO2 emissions. We present the Vessel Schedule Recovery Problem (VSRP) to evaluate a given disruption scenario and to select a recovery action balancing the trade off between increased bunker...

  19. Pressure vessel and method therefor

    Science.gov (United States)

    Saunders, Timothy

    2017-09-05

    A pressure vessel includes a pump having a passage that extends between an inlet and an outlet. A duct at the pump outlet includes at least one dimension that is adjustable to facilitate forming a dynamic seal that limits backflow of gas through the passage.

  20. Pressure vessel having continuous sidewall

    Science.gov (United States)

    Simon, Xavier D. (Inventor); Barackman, Victor J. (Inventor)

    2011-01-01

    A spacecraft pressure vessel has a tub member. A sidewall member is coupled to the tub member so that a bottom section of the sidewall member extends from an attachment intersection with the tub member and away from the tub member. The bottom section of the sidewall member receives and transfers a load through the sidewall member.

  1. John Strong (1941 - 2006)

    CERN Multimedia

    Wickens, F

    Our friend and colleague John Strong was cruelly taken from us by a brain tumour on Monday 31st July, a few days before his 65th birthday John started his career working with a group from Westfield College, under the leadership of Ted Bellamy. He obtained his PhD and spent the early part of his career on experiments at Rutherford Appleton Laboratory (RAL), but after the early 1970s his research was focussed on experiments in CERN. Over the years he made a number of notable contributions to experiments in CERN: The Omega spectrometer adopted a system John had originally developed for experiments at RAL using vidicon cameras to record the sparks in the spark chambers; He contributed to the success of NA1 and NA7, where he became heavily involved in the electronic trigger systems; He was responsible for the second level trigger system for the ALEPH detector and spent five years leading a team that designed and built the system, which ran for twelve years with only minor interventions. Following ALEPH he tur...

  2. Stirring Strongly Coupled Plasma

    CERN Document Server

    Fadafan, Kazem Bitaghsir; Rajagopal, Krishna; Wiedemann, Urs Achim

    2009-01-01

    We determine the energy it takes to move a test quark along a circle of radius L with angular frequency w through the strongly coupled plasma of N=4 supersymmetric Yang-Mills (SYM) theory. We find that for most values of L and w the energy deposited by stirring the plasma in this way is governed either by the drag force acting on a test quark moving through the plasma in a straight line with speed v=Lw or by the energy radiated by a quark in circular motion in the absence of any plasma, whichever is larger. There is a continuous crossover from the drag-dominated regime to the radiation-dominated regime. In the crossover regime we find evidence for significant destructive interference between energy loss due to drag and that due to radiation as if in vacuum. The rotating quark thus serves as a model system in which the relative strength of, and interplay between, two different mechanisms of parton energy loss is accessible via a controlled classical gravity calculation. We close by speculating on the implicati...

  3. Strong-interaction nonuniversality

    International Nuclear Information System (INIS)

    Volkas, R.R.; Foot, R.; He, X.; Joshi, G.C.

    1989-01-01

    The universal QCD color theory is extended to an SU(3) 1 direct product SU(3) 2 direct product SU(3) 3 gauge theory, where quarks of the ith generation transform as triplets under SU(3)/sub i/ and singlets under the other two factors. The usual color group is then identified with the diagonal subgroup, which remains exact after symmetry breaking. The gauge bosons associated with the 16 broken generators then form two massive octets under ordinary color. The interactions between quarks and these heavy gluonlike particles are explicitly nonuniversal and thus an exploration of their physical implications allows us to shed light on the fundamental issue of strong-interaction universality. Nonuniversality and weak flavor mixing are shown to generate heavy-gluon-induced flavor-changing neutral currents. The phenomenology of these processes is studied, as they provide the major experimental constraint on the extended theory. Three symmetry-breaking scenarios are presented. The first has color breaking occurring at the weak scale, while the second and third divorce the two scales. The third model has the interesting feature of radiatively induced off-diagonal Kobayashi-Maskawa matrix elements

  4. Vessel tree extraction using locally optimal paths

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau; van Ginneken, Bram; de Bruijne, Marleen

    2010-01-01

    This paper proposes a method to extract vessel trees by continually extending detected branches with locally optimal paths. Our approach uses a cost function from a multi scale vessel enhancement filter. Optimal paths are selected based on rules that take into account the geometric characteristics...... of the vessel tree. Experiments were performed on 10 low dose chest CT scans for which the pulmonary vessel trees were extracted. The proposed method is shown to extract a better connected vessel tree and extract more of the small peripheral vessels in comparison to applying a threshold on the output...

  5. Development of a preparation and staining method for fetal erythroblasts in maternal blood : Simultaneous immunocytochemical staining and FISH analysis

    NARCIS (Netherlands)

    Oosterwijk, JC; Mesker, WE; Ouwerkerk-van Velzen, MCM; Knepfle, CFHM; Wiesmeijer, KC; van den Burg, MJM; Beverstock, GC; Bernini, LF; van Ommen, Gert-Jan B; Kanhai, HHH; Tanke, HJ

    1998-01-01

    In order to detect fetal nucleated red blood cells (NRBCs) in maternal blood, a protocol was developed which aimed at producing a reliable staining method for combined immunocytochemical and FISH analysis. The technique had to be suitable for eventual automated screening of slides. Chorionic villi

  6. String Vessel Formation is Increased in the Brain of Parkinson Disease.

    Science.gov (United States)

    Yang, Panzao; Pavlovic, Darja; Waldvogel, Henry; Dragunow, Mike; Synek, Beth; Turner, Clinton; Faull, Richard; Guan, Jian

    2015-01-01

    String vessels are collapsed basement membrane without endothelium and have no function in circulation. String vessel formation contributes to vascular degeneration in Alzheimer disease. By comparing to age-matched control cases we have recently reported endothelial degeneration in brain capillaries of human Parkinson disease (PD). Current study evaluated changes of basement membrane of capillaries, string vessel formation and their association with astrocytes, blood-brain-barrier integrity and neuronal degeneration in PD. Brain tissue from human cases of PD and age-matched controls was used. Immunohistochemical staining for collagen IV, GFAP, NeuN, tyrosine hydroxylase, fibrinogen and Factor VIII was evaluated by image analysis in the substantia nigra, caudate nucleus and middle frontal gyrus. While the basement-membrane-associated vessel density was similar between the two groups, the density of string vessels was significantly increased in the PD cases, particularly in the substantia nigra. Neuronal degeneration was found in all brain regions. Astrocytes and fibrinogen were increased in the caudate nuclei of PD cases compared with control cases. Endothelial degeneration and preservation of basement membrane result in an increase of string vessel formation in PD. The data may suggest a possible role for cerebral hypoperfusion in the neuronal degeneration characteristic of PD, which needs further investigation. Elevated astrocytosis in the caudate nucleus of PD cases could be associated with disruption of the blood-brain barrier in this brain region.

  7. AFSC/FMA/Vessel Assessment Logging

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Vessels fishing trawl gear, vessels fishing hook-and-line and pot gear that are also greater than 57.5 feet overall, and shoreside and floating processing facilities...

  8. 2013 EPA Vessels General Permit (VGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Information for any vessel that submitted a Notice of Intent (NOI), Notice of Termination (NOT), or annual report under EPA's 2013 Vessel General Permit (VGP)....

  9. Multicolored stain-free histopathology with coherent Raman imaging.

    Science.gov (United States)

    Freudiger, Christian W; Pfannl, Rolf; Orringer, Daniel A; Saar, Brian G; Ji, Minbiao; Zeng, Qing; Ottoboni, Linda; Wei, Ying; Ying, Wei; Waeber, Christian; Sims, John R; De Jager, Philip L; Sagher, Oren; Philbert, Martin A; Xu, Xiaoyin; Kesari, Santosh; Xie, X Sunney; Young, Geoffrey S

    2012-10-01

    Conventional histopathology with hematoxylin & eosin (H&E) has been the gold standard for histopathological diagnosis of a wide range of diseases. However, it is not performed in vivo and requires thin tissue sections obtained after tissue biopsy, which carries risk, particularly in the central nervous system. Here we describe the development of an alternative, multicolored way to visualize tissue in real-time through the use of coherent Raman imaging (CRI), without the use of dyes. CRI relies on intrinsic chemical contrast based on vibrational properties of molecules and intrinsic optical sectioning by nonlinear excitation. We demonstrate that multicolor images originating from CH(2) and CH(3) vibrations of lipids and protein, as well as two-photon absorption of hemoglobin, can be obtained with subcellular resolution from fresh tissue. These stain-free histopathological images show resolutions similar to those obtained by conventional techniques, but do not require tissue fixation, sectioning or staining of the tissue analyzed.

  10. PENGARUH SPIRITUALITAS, INTELEKTUALITAS, DAN PROFESIONALISME TERHADAP KINERJA DOSEN STAIN SALATIGA

    Directory of Open Access Journals (Sweden)

    Abdul Aziz Nugraha Pratama

    2014-12-01

    Full Text Available This study aims to determine the effect of each variable spirituality, intellect, and professionalism of the lecturers performance STAIN Salatiga. The population of this study are all tenured State Institute of Islamic Studies (STAIN Salatiga as many as 107 people. The sampling technique used in this study using simple random sampling and 65 were taken as respondents. With quantitative methods and analysis techniques that use moderated regression analysis (MRA, it can be concluded that (1 spirituality is partially not significantly affect the performance of the faculty; (2 the partial intellect does not significantly affect the performance of the faculty; (3 professionalism partially positive and significant effect on the performance of the lecturer. (4 spirituality, intellect and professionalism of lecturers jointly affect the performance of the lecturer. The study also found that the majority of respondents aged very productive, but they are staying at very far away from the campus.

  11. Angiolymphoid hyperplasia with eosinophilia developing within a port wine stain.

    Science.gov (United States)

    Manton, Robert N; Itinteang, Tinte; de Jong, Sophie; Brasch, Helen D; Tan, Swee T

    2016-01-01

    A 19-year-old male with a port wine stain on the base of his neck presented with a 5-month history of gradual thickening of the involved skin which interfered with clothing and caused repeated bleeding. The lesion was excised and histopathologic examination revealed angiolymphoid hyperplasia with eosinophilia (ALHE) arising from the pre-existing port wine stain - a rare finding with only one previously reported case. Additionally the lesion was associated with elevated serum renin levels which virtually normalized following excision of the lesion. We further demonstrated the expression of angiotensin converting enzyme and angiotensin II receptors 1 and 2 by the lesion and discuss the possible role of the renin-angiotensin system in this condition. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Selection of Ovine Oocytes by Brilliant Cresyl Blue Staining

    Directory of Open Access Journals (Sweden)

    Liqin Wang

    2012-01-01

    Full Text Available Sheep oocytes derived from the ovaries collected from the slaughterhouse are often used for research on in vitro embryo production, animal cloning, transgenesis, embryonic stem cells, and other embryo biotechnology aspects. Improving the in vitro culture efficiency of oocytes can provide more materials for similar studies. Generally, determination of oocyte quality is mostly based on the layers of cumulus cells and cytoplasm or cytoplasm uniformity and colors. This requires considerable experience to better identify oocyte quality because of the intense subjectivity involved (Gordon (2003, Madison et al. (1992 and De Loos et al. (1992. BCB staining is a function of glucose-6-phosphate dehydrogenase (G6PD activity, an enzyme synthesized in developing oocytes, which decreases in activity with maturation. Therefore, unstained oocytes (BCB− are high in G6PD activity, while the less mature oocytes stains are deep blue (BCB+ due to insuffcient G6PD activity to decolorize the BCB dye.

  13. Selection of Ovine Oocytes by Brilliant Cresyl Blue Staining

    Science.gov (United States)

    Wang, Liqin; Lin, Jiapeng; Huang, Juncheng; Wang, Jing; Zhao, Yuncheng; Chen, Tong

    2012-01-01

    Sheep oocytes derived from the ovaries collected from the slaughterhouse are often used for research on in vitro embryo production, animal cloning, transgenesis, embryonic stem cells, and other embryo biotechnology aspects. Improving the in vitro culture efficiency of oocytes can provide more materials for similar studies. Generally, determination of oocyte quality is mostly based on the layers of cumulus cells and cytoplasm or cytoplasm uniformity and colors. This requires considerable experience to better identify oocyte quality because of the intense subjectivity involved (Gordon (2003), Madison et al. (1992) and De Loos et al. (1992)). BCB staining is a function of glucose-6-phosphate dehydrogenase (G6PD) activity, an enzyme synthesized in developing oocytes, which decreases in activity with maturation. Therefore, unstained oocytes (BCB−) are high in G6PD activity, while the less mature oocytes stains are deep blue (BCB+) due to insuffcient G6PD activity to decolorize the BCB dye. PMID:22675245

  14. Technique and Feasibility of a Dual Staining Method for Estrogen Receptors and AgNORs

    Directory of Open Access Journals (Sweden)

    Lukas Günther

    2000-01-01

    Full Text Available A new staining method for dual demonstration of Estrogen receptors (ER and argyrophilc Nucleolus‐Organizer Regions (AgNORs was developed. To rule out possible reciprocal effects, serial slides of 10 invasive ductale breast cancers were stained with either the single staining method or the simultaneous ER/AgNOR‐staining method and investigated comparatively. By measuring the slides with the image analysis system AMBA, reciprocal effects could be excluded. It was proven that dual staining of both markers results in a reproducible and specific staining result. We concluded that it is justified to measure AgNORs in immunohistochemically stained cells.

  15. An improved method for staining cell colonies in clonogenic assays

    OpenAIRE

    Guda, Kishore; Natale, Leanna; Markowitz, Sanford D.

    2007-01-01

    Clonogenic assay is a widely used experimental approach to test for the effects of drugs/genes on the growth and proliferative characteristics of cells in vitro. Accurate quantitation of treatment effects in clonogeneic assays depends on the ability to visualize and count cell colonies precisely. We report a novel method (referred as ETeB) for staining cell colonies grown on plastic and specially coated substrates like collagen. Using colon cancer cell lines grown on plastic and collagen, we ...

  16. Solid-Color Stains on Western Redcedar and Redwood Siding

    Science.gov (United States)

    Mark Knaebe

    2013-01-01

    You have decided to put wood siding on your new house. Several questions are probably going through your mind: “What’s the best type of wood?” “Should I use paint or stain?” “Should I apply the finish before or after I install the siding?”

  17. Myeloperoxidase staining in the diagnosis of aggressive periodontitis

    OpenAIRE

    Singh, Sukhdeep; Acharya, Anirudh B.; Kumar, S. C. Veerendra

    2011-01-01

    Aims: To evaluate neutrophil myeloperoxidase (MPO) staining procedure as a reliable, affordable and easily available diagnostic assay for aggressive periodontitis. Materials and Methods: Fifteen subjects were recruited in the study wherein five each were diagnosed as aggressive periodontitis and chronic periodontitis respectively, and five were periodontally healthy. Three millilitres (ml) of venous blood was collected using Vacutainers containing ethylene diamine tetra acetate (EDTA) and was...

  18. Meibomian orifices and Marx's line. Studied by triple vital staining.

    Science.gov (United States)

    Norn, M

    1985-12-01

    The ciliary margins of the lower lids have been vital stained by the lipid-specific Sudan III powder, fluorescein 0.1% and the bottom of the lacrimal river (Marx's line) by lissamine green 1% in 100 cases. The Meibomian orifices are situated in a straight row just in front of the Marx's line in the lipid phase. With increasing age (greater than 50 years) the orifices are more often displaced and also discharge their lipid in the depth of the aqueous phase. The number averaged 21.5 in the lipid phase and 1.7 in the aqueous phase. Active orifices staining with lipid were found in 45% of all orifices in normals, independent of age, and were increased in conjunctivitis in the lipid phase. Lissamine green-stained orifices were independent of age, phase and diagnosis. The anterior edge of Marx's line may run an irregular course in elderly normals (greater than 50 years), significantly more often in conjunctivitis and blepharitis.

  19. Survival of Staphylococcus pseudintermedius in modified Romanowsky staining solutions.

    Science.gov (United States)

    Misan, Angus; Chan, Wei Yee; Trott, Darren; Hill, Peter B

    2017-08-01

    Stains that are used regularly for patient-side diagnosis to rapidly identify bacterial and fungal infections could become contaminated by common pathogens, such as Staphylococcus pseudintermedius, during slide immersion. To determine whether the inoculation of S. pseudintermedius into modified Romanowsky type stains (Quick Dip ® ) results in viable bacterial contamination and whether this is influenced by the addition of organic debris (canine hair and skin). A clinical isolate of S. pseudintermedius was inoculated into clean and organically contaminated Quick Dip ® solutions (methanol fixative, eosin, methylene blue), and positive (broth) and negative (bleach) controls. Each solution was tested for the presence of viable bacteria by counting the number of colony forming units (CFU/mL) at various time points. Solutions also were examined under high power microscopy to count the number of visible bacteria at each time point. Staphylococcus pseudintermedius was able to survive in the clean and contaminated Quick Dip ® stains for at least one hour, but by 24 h no viable bacteria remained. Survival of the bacteria was not supported in the fixative at any time point. Staphylococcus pseudintermedius remained visible under high power microscopy for up to 2 weeks in all organically contaminated solutions of the Quick Dip ® set. Staphylococcus pseudintermedius only remains viable in eosin and methylene blue for short periods of time, but the prolonged visibility of dead organisms could theoretically lead to the misdiagnosis of cytology samples. © 2017 ESVD and ACVD.

  20. Academic Research Vessels 1985-1990.

    Science.gov (United States)

    1982-01-01

    replacement, and only one of these vessels was larger than 100 ft. In addition to the recently completed replacements of the EASTWARD and the GILLISS by... GILLISS and R/V EASTWARD by two new coastal vessels, the R/V CAPE FLORIDA and R/V CAPE HATTERAS. These estimates for the cost of vessel replacement

  1. 33 CFR 151.1512 - Vessel safety.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Vessel safety. 151.1512 Section... River § 151.1512 Vessel safety. Nothing in this subpart relieves the master of the responsibility for ensuring the safety and stability of the vessel or the safety of the crew and passengers, or any other...

  2. 50 CFR 300.125 - Vessel identification.

    Science.gov (United States)

    2010-10-01

    ... contrasting color to the background at least 18 inches (45.7 cm) in height for fishing vessels over 65 ft (19....125 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS Vessels of the United States Fishing in Colombian Treaty Waters § 300.125 Vessel identification...

  3. Reactor vessel supported by flexure member

    International Nuclear Information System (INIS)

    Crawford, J.D.; Pankow, B.

    1975-01-01

    A description is given of a reactor pressure vessel which is provided with vertical support means in the form of circumferentially spaced columns upon which the vessel is mounted. The columns are adapted to undergo flexure in order to accommodate the thermally induced displacements experienced by the vessel during operational transients

  4. Manufacturing technologies of PWR pressure vessels

    International Nuclear Information System (INIS)

    Qin Xubin

    1991-01-01

    Pressure vessels belong to the main component of PWR plants. Starting with describing the manufacture of pressure vessel components and their assembly, the manufacturing technologies of pressure vessels are briefly presented with regards to welding, heat treatment, inspections and testing. In addition, quality assurance during the manufacture is presented with emphasis

  5. Model tests for prestressed concrete pressure vessels

    International Nuclear Information System (INIS)

    Stoever, R.

    1975-01-01

    Investigations with models of reactor pressure vessels are used to check results of three dimensional calculation methods and to predict the behaviour of the prototype. Model tests with 1:50 elastic pressure vessel models and with a 1:5 prestressed concrete pressure vessel are described and experimental results are presented. (orig.) [de

  6. Comparative study of the efficacy of Wright-Giemsa stain and Liu's stain in the detection of Auer rods in acute promyelocytic leukemia.

    Science.gov (United States)

    Yue, Qing Fang; Xiong, Bei; Chen, Wan Xin; Liu, Xin Yue

    2014-07-01

    In view of the importance of Auer rods in the rapid diagnosis of acute promyelocytic leukemia, we compared the results of Wright-Giemsa stain and Liu's stain (a rapid and simple stain, which is also a kind of modified Romanowsky stain) in the detection of Auer rods. This study was based on 53 cases of acute promyelocytic leukemia. Two staining methods were respectively performed on the bone marrow smears of these cases, and presence of Auer rods as well as nuclear features, cytoplasmic features and the degree of granularity of the cytoplasm were compared in each case. Our results showed that the occurrence of Auer rods as well as faggots in leukemic promyelocytes were significantly higher under Liu's stain than under Wright-Giemsa stain. Significant differences also existed in the occurrence of hypergranular cells and cytoplasmic protrusions between smears stained with Liu's stain and Wright-Giemsa stain. Liu's stain is important for the rapid diagnosis of suspicious APL, especially in recognizing Auer rods. Copyright © 2014 Elsevier GmbH. All rights reserved.

  7. A COMPARATIVE STUDY TO SEE THE UTILITY OF MODIFIED ULTRAFAST PAPANICOLAOU (MUFP STAIN OVER STANDARD PAP STAIN IN ROUTINE FNA SMEARS

    Directory of Open Access Journals (Sweden)

    Ruchi Khajuria

    2016-07-01

    Full Text Available BACKGROUND Pap stain is an excellent method to review the cytological specimen; however, it is time consuming and costly. Various modifications have been developed in Pap stain of which latest is Modified Ultrafast Pap (MUFP stain which is hybrid of the technique by Romanowsky and conventional Pap stain to reduce the staining time to 90 seconds. AIM Aim of this study was to assess the feasibility and applicability of MUFP stain in fine needle aspiration smears of various organs. MATERIAL AND METHODS This prospective study was carried out in the cytopathology laboratory of GMC, Jammu for a period of 6 months from December 2015 to May 2016. A total no of 200 specimens were collected. The samples included 80 lymph node aspiration samples, 40 thyroid FNA samples, 50 breast FNA samples, 25 soft tissue aspirations and 5 salivary gland aspirations. Two smears were kept for fixation in 95% ethanol for staining with standard Pap stain and 2 were air dried for MUFP staining. RESULTS A correct diagnosis was achieved in all the cases. Background was similar in both staining methods. However, well-preserved cell morphology, crisp nuclear outline, good overall staining were well seen with MUFP method when compared with the standard Pap method. CONCLUSION The findings of this study support the use of MUFP method in cytology laboratory over standard Pap method.

  8. Determination of thermal and physical properties of port-wine stain lesions using pulsed photothermal radiometry

    Science.gov (United States)

    Nelson, J. Stuart; Jacques, Steven L.; Wright, William H.

    1992-06-01

    A method for quantitative characterization of port wine stain (PWS) is presented. Pulsed photothermal radiometry (PPTR) uses a non-invasive infrared radiometry system to measure changes in surface temperature induced by pulsed radiation. When a pulsed laser is used to irradiate a PWS, an initial temperature jump (T-jump) is seen due to the heating of the epidermis as a result of melanin absorption. Subsequently, heat generated in the subsurface blood vessels due to hemoglobin absorption is detected by PPTR as a delayed thermal wave as the heat diffuses toward the skin surface. The time delay and magnitude of the delayed PPTR signal indicate the depth and thickness of the PWS. In this report, we present an initial clinical study of PPTR measurements on PWS patients. Computer simulations of various classes of PWS illustrate how the PPTR signal depends on the concentration of epidermal melanin, and depth and thickness of the PWS. The goal of this research is to provide a means of characterizing PWS before initiating therapy, guiding laser dosimetry, and advising the patient as to the time course and efficacy of the planned protocol.

  9. Captopril improves tumor nanomedicine delivery by increasing tumor blood perfusion and enlarging endothelial gaps in tumor blood vessels.

    Science.gov (United States)

    Zhang, Bo; Jiang, Ting; Tuo, Yanyan; Jin, Kai; Luo, Zimiao; Shi, Wei; Mei, Heng; Hu, Yu; Pang, Zhiqing; Jiang, Xinguo

    2017-12-01

    Poor tumor perfusion and unfavorable vessel permeability compromise nanomedicine drug delivery to tumors. Captopril dilates blood vessels, reducing blood pressure clinically and bradykinin, as the downstream signaling moiety of captopril, is capable of dilating blood vessels and effectively increasing vessel permeability. The hypothesis behind this study was that captopril can dilate tumor blood vessels, improving tumor perfusion and simultaneously enlarge the endothelial gaps of tumor vessels, therefore enhancing nanomedicine drug delivery for tumor therapy. Using the U87 tumor xenograft with abundant blood vessels as the tumor model, tumor perfusion experiments were carried out using laser Doppler imaging and lectin-labeling experiments. A single treatment of captopril at a dose of 100 mg/kg significantly increased the percentage of functional vessels in tumor tissues and improved tumor blood perfusion. Scanning electron microscopy of tumor vessels also indicated that the endothelial gaps of tumor vessels were enlarged after captopril treatment. Immunofluorescence-staining of tumor slices demonstrated that captopril significantly increased bradykinin expression, possibly explaining tumor perfusion improvements and endothelial gap enlargement. Additionally, imaging in vivo, imaging ex vivo and nanoparticle distribution in tumor slices indicated that after a single treatment with captopril, the accumulation of 115-nm nanoparticles in tumors had increased 2.81-fold with a more homogeneous distribution pattern in comparison to non-captopril treated controls. Finally, pharmacodynamics experiments demonstrated that captopril combined with paclitaxel-loaded nanoparticles resulted in the greatest tumor shrinkage and the most extensive necrosis in tumor tissues among all treatment groups. Taken together, the data from the present study suggest a novel strategy for improving tumor perfusion and enlarging blood vessel permeability simultaneously in order to improve

  10. Integrating Multiple Autonomous Underwater Vessels, Surface Vessels and Aircraft into Oceanographic Research Vessel Operations

    Science.gov (United States)

    McGillivary, P. A.; Borges de Sousa, J.; Martins, R.; Rajan, K.

    2012-12-01

    Autonomous platforms are increasingly used as components of Integrated Ocean Observing Systems and oceanographic research cruises. Systems deployed can include gliders or propeller-driven autonomous underwater vessels (AUVs), autonomous surface vessels (ASVs), and unmanned aircraft systems (UAS). Prior field campaigns have demonstrated successful communication, sensor data fusion and visualization for studies using gliders and AUVs. However, additional requirements exist for incorporating ASVs and UASs into ship operations. For these systems to be optimally integrated into research vessel data management and operational planning systems involves addressing three key issues: real-time field data availability, platform coordination, and data archiving for later analysis. A fleet of AUVs, ASVs and UAS deployed from a research vessel is best operated as a system integrated with the ship, provided communications among them can be sustained. For this purpose, Disruptive Tolerant Networking (DTN) software protocols for operation in communication-challenged environments help ensure reliable high-bandwidth communications. Additionally, system components need to have considerable onboard autonomy, namely adaptive sampling capabilities using their own onboard sensor data stream analysis. We discuss Oceanographic Decision Support System (ODSS) software currently used for situational awareness and planning onshore, and in the near future event detection and response will be coordinated among multiple vehicles. Results from recent field studies from oceanographic research vessels using AUVs, ASVs and UAS, including the Rapid Environmental Picture (REP-12) cruise, are presented describing methods and results for use of multi-vehicle communication and deliberative control networks, adaptive sampling with single and multiple platforms, issues relating to data management and archiving, and finally challenges that remain in addressing these technological issues. Significantly, the

  11. Triple –E Vessels: Tonnage Measurement and Suez Canal Dues Assessment

    Directory of Open Access Journals (Sweden)

    Elsayed Hussein Galall

    2015-08-01

    Full Text Available Container is growing faster than GDP, Shipping lines always attempt to augment efficiencyby reducing cost and by attracting larger volumes of containers. As a result rising containerfreight rates the lines have been driven to increase economic of scale, by building mega shipsand fewer mere efficient port calls. In 2011 Maersk line ordered up to 20 new “Triple- E “Class of container vessels deliversbetween 2013- 2015. These class of mega container vessels have its way through Suez Canal,other companies CMA, CGM also ordered this type of mega container vessels, in order toreach higher profits due to the achieved economics of scale It is believed that 20000 TEUcould be the next target size. Present mega container fleet and any future feasible potential vessel capacity expansionmore than 18000 TEU put Suez Canal route in strong competitive position. MeanwhilePanama Canal will not be able to handle vessels larger than 12600 TEU even after itsexpansion in 2015.

  12. Vessel for storing and disposing radioactive waste

    International Nuclear Information System (INIS)

    Takakura, Masahide.

    1997-01-01

    A vessel for storing and disposing radioactive wastes is composed of a containing vessel main body having an opening and a lid capable of fitting with the opening. The containing vessel main body is made into a cylindrical shape which can contain radioactive wastes therein. The containing vessel main body and the lid are made of a reinforced material such as carbon steels and stainless steels respectively. A plurality of fin set up-seats are disposed, each at a same distance, detachably to the outer surface of the containing vessel main body in parallel with the axial line of the containing vessel main body. Heat dissipating fins are secured on the outer surface of the fin set-up-seats. With such a constitution, there can be obtained a vessel suitable to underground disposal of radioactive wastes after cooling and storing them till removal of after heat. (I.N.)

  13. What is cerebral small vessel disease?

    International Nuclear Information System (INIS)

    Onodera, Osamu

    2011-01-01

    An accumulating amount of evidence suggests that the white matter hyperintensities on T 2 weighted brain magnetic resonance imaging predict an increased risk of dementia and gait disturbance. This state has been proposed as cerebral small vessel disease, including leukoaraiosis, Binswanger's disease, lacunar stroke and cerebral microbleeds. However, the concept of cerebral small vessel disease is still obscure. To understand the cerebral small vessel disease, the precise structure and function of cerebral small vessels must be clarified. Cerebral small vessels include several different arteries which have different anatomical structures and functions. Important functions of the cerebral small vessels are blood-brain barrier and perivasucular drainage of interstitial fluid from the brain parenchyma. Cerebral capillaries and glial endfeet, take an important role for these functions. However, the previous pathological investigations on cerebral small vessels have focused on larger arteries than capillaries. Therefore little is known about the pathology of capillaries in small vessel disease. The recent discoveries of genes which cause the cerebral small vessel disease indicate that the cerebral small vessel diseases are caused by a distinct molecular mechanism. One of the pathological findings in hereditary cerebral small vessel disease is the loss of smooth muscle cells, which is an also well-recognized finding in sporadic cerebral small vessel disease. Since pericytes have similar character with the smooth muscle cells, the pericytes should be investigated in these disorders. In addition, the loss of smooth muscle cells may result in dysfunction of drainage of interstitial fluid from capillaries. The precise correlation between the loss of smooth muscle cells and white matter disease is still unknown. However, the function that is specific to cerebral small vessel may be associated with the pathogenesis of cerebral small vessel disease. (author)

  14. Quantification of polysaccharides fixed to Gram stained slides using lactophenol cotton blue and digital image processing.

    Science.gov (United States)

    Ericksen, Bryan

    2015-01-01

    Dark blue rings and circles emerged when the non-specific polysaccharide stain lactophenol cotton blue was added to Gram stained slides. The dark blue staining is attributable to the presence of capsular polysaccharides and bacterial slime associated with clumps of Gram-negative bacteria.  Since all bacterial cells are glycosylated and concentrate polysaccharides from the media, the majority of cells stain light blue. The contrast between dark and light staining is sufficient to enable a digital image processing thresholding technique to be quantitative with little background noise. Prior to the addition of lactophenol cotton blue, the Gram-stained slides appeared unremarkable, lacking ubiquitous clumps or stained polysaccharides.  Adding lactophenol cotton blue to Gram stained slides is a quick and inexpensive way to screen cell cultures for bacterial slime, clumps and biofilms that are invisible using the Gram stain alone.

  15. Appearance of granulated cells in blood films stained by automated aqueous versus methanolic Romanowsky methods.

    Science.gov (United States)

    Allison, Robin W; Velguth, Karen E

    2010-03-01

    Romanowsky stains are used routinely by veterinary clinical pathology laboratories for cytologic and blood film evaluations. Automated stainers are available for both aqueous and methanolic Romanowsky stains. Mast cell granules and canine distemper virus inclusions are known to stain differently by these 2 methods, but we have noticed differences in the staining characteristics of other granulated cells. The aim of this study was to investigate and document the variable appearance of basophils and large granular lymphocytes in blood films stained using aqueous and methanolic Romanowsky methods. Cytologic preparations from 1 canine mast cell tumor and blood films from 8 dogs, 1 cat, 1 rabbit, and 1 ostrich were stained using an automated aqueous stain (Aerospray 7120, with and without a predip fixative) and an automated methanolic stain (Hematek). Staining quality and intensity of the cytoplasmic granules in mast cells, basophils, and large granular lymphocytes was evaluated subjectively. Cytoplasmic granules of mast cells, basophils, and large granular lymphocytes stained poorly or not at all with the automated aqueous stain but stained prominently and were readily identified with the automated methanolic stain. Use of the predip fixative with the Aerospray method improved the visibility of basophil granules but not mast cell granules, and had a variable affect on the visibility of granules in large granular lymphocytes. Clinical pathologists should be aware of the staining methodology used on the slides they evaluate to avoid incorrect interpretation of granulated cell populations.

  16. Microseismic reverse time migration with a multi-cross-correlation staining algorithm for fracture imaging

    Science.gov (United States)

    Yuan, Congcong; Jia, Xiaofeng; Liu, Shishuo; Zhang, Jie

    2018-02-01

    Accurate characterization of hydraulic fracturing zones is currently becoming increasingly important in production optimization, since hydraulic fracturing may increase the porosity and permeability of the reservoir significantly. Recently, the feasibility of the reverse time migration (RTM) method has been studied for the application in imaging fractures during borehole microseismic monitoring. However, strong low-frequency migration noise, poorly illuminated areas, and the low signal to noise ratio (SNR) data can degrade the imaging results. To improve the quality of the images, we propose a multi-cross-correlation staining algorithm to incorporate into the microseismic reverse time migration for imaging fractures using scattered data. Under the modified RTM method, our results are revealed in two images: one is the improved RTM image using the multi-cross-correlation condition, and the other is an image of the target region using the generalized staining algorithm. The numerical examples show that, compared with the conventional RTM, our method can significantly improve the spatial resolution of images, especially for the image of target region.

  17. Heterogeneity in Li-Fraumeni families: p53 mutation analysis and immunohistochemical staining.

    Science.gov (United States)

    MacGeoch, C; Turner, G; Bobrow, L G; Barnes, D M; Bishop, D T; Spurr, N K

    1995-03-01

    We have screened two families for constitutional TP53 mutations, one family with Li-Fraumeni syndrome and the other with features of this syndrome. We report a germline mutation in exon 7 of the TP53 gene in the family with "Li-Fraumeni-like" syndrome. The mutation occurred at codon 245 and causes a Gly-Ser amino acid change. It was inherited by both affected and unaffected subjects. Malignant tumours from all members of this family showed strong positive nuclear immunohistochemical staining with antibodies CM-1 and DO1, directed against TP53. In contrast, no constitutional TP53 mutations were found in a "classic" Li-Fraumeni family. In this family positive staining was seen in both malignant and normal tissues. These results support previous findings that variants of the Li-Fraumeni syndrome exist since not all LFS families carry TP53 germline mutations. Secondly, immunohistochemical positivity is not synonymous with an underlying mutation and is therefore inadequate as an exclusive diagnostic marker.

  18. Progress of ITER vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ioki, K., E-mail: Kimihiro.Ioki@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Bayon, A. [F4E, c/ Josep Pla, No. 2, Torres Diagonal Litoral, Edificio B3, E-08019 Barcelona (Spain); Choi, C.H.; Daly, E.; Dani, S.; Davis, J.; Giraud, B.; Gribov, Y.; Hamlyn-Harris, C.; Jun, C.; Levesy, B. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Kim, B.C. [NFRI, 52 Yeoeundong Yuseonggu, Daejeon 305-333 (Korea, Republic of); Kuzmin, E. [NTC “Sintez”, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Le Barbier, R.; Martinez, J.-M. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Pathak, H. [ITER-India, A-29, GIDC Electronic Estate, Sector 25, Gandhinagar 382025 (India); Preble, J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Sa, J.W. [NFRI, 52 Yeoeundong Yuseonggu, Daejeon 305-333 (Korea, Republic of); Terasawa, A.; Utin, Yu. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); and others

    2013-10-15

    Highlights: ► This covers the overall status and progress of the ITER vacuum vessel activities. ► It includes design, R and D, manufacturing and approval process of the regulators. ► The baseline design was completed and now manufacturing designs are on-going. ► R and D includes ISI, dynamic test of keys and lip-seal welding/cutting technology. ► The VV suppliers produced full-scale mock-ups and started VV manufacturing. -- Abstract: Design modifications were implemented in the vacuum vessel (VV) baseline design in 2011–2012 for finalization. The modifications are mostly due to interface components, such as support rails and feedthroughs for the in-vessel coils (IVC). Manufacturing designs are being developed at the domestic agencies (DAs) based on the baseline design. The VV support design was also finalized and tests on scale mock-ups are under preparation. Design of the in-wall shielding (IWS) has progressed, considering the assembly methods and the required tolerances. Further modifications are required to be consistent with the DAs’ manufacturing designs. Dynamic tests on the inter-modular and stub keys to support the blanket modules are being performed to measure the dynamic amplification factor (DAF). An in-service inspection (ISI) plan has been developed and R and D was launched for ISI. Conceptual design of the VV instrumentation has been developed. The VV baseline design was approved by the agreed notified body (ANB) in accordance with the French Nuclear Pressure Equipment Order procedure.

  19. Progress of ITER vacuum vessel

    International Nuclear Information System (INIS)

    Ioki, K.; Bayon, A.; Choi, C.H.; Daly, E.; Dani, S.; Davis, J.; Giraud, B.; Gribov, Y.; Hamlyn-Harris, C.; Jun, C.; Levesy, B.; Kim, B.C.; Kuzmin, E.; Le Barbier, R.; Martinez, J.-M.; Pathak, H.; Preble, J.; Sa, J.W.; Terasawa, A.; Utin, Yu.

    2013-01-01

    Highlights: ► This covers the overall status and progress of the ITER vacuum vessel activities. ► It includes design, R and D, manufacturing and approval process of the regulators. ► The baseline design was completed and now manufacturing designs are on-going. ► R and D includes ISI, dynamic test of keys and lip-seal welding/cutting technology. ► The VV suppliers produced full-scale mock-ups and started VV manufacturing. -- Abstract: Design modifications were implemented in the vacuum vessel (VV) baseline design in 2011–2012 for finalization. The modifications are mostly due to interface components, such as support rails and feedthroughs for the in-vessel coils (IVC). Manufacturing designs are being developed at the domestic agencies (DAs) based on the baseline design. The VV support design was also finalized and tests on scale mock-ups are under preparation. Design of the in-wall shielding (IWS) has progressed, considering the assembly methods and the required tolerances. Further modifications are required to be consistent with the DAs’ manufacturing designs. Dynamic tests on the inter-modular and stub keys to support the blanket modules are being performed to measure the dynamic amplification factor (DAF). An in-service inspection (ISI) plan has been developed and R and D was launched for ISI. Conceptual design of the VV instrumentation has been developed. The VV baseline design was approved by the agreed notified body (ANB) in accordance with the French Nuclear Pressure Equipment Order procedure

  20. Color stability and staining of silorane after prolonged chemical challenges

    DEFF Research Database (Denmark)

    de Jesus, Vivian CBR; Martinelli, Nata Luiz; Poli-Frederico, Regina Célia

    methacrylate (Filtek Z250, 3M ESPE; Filtek Z350XT, 3M ESPE; Master Fill, Biodinâmica) or silorane-based (Filtek P90, 3M ESPE) composite materials. Initial color was registered in a spectrophotometer. Specimens were divided in four groups and individually stored at 37°C in 0.02N citric acid, 0.02N phosphoric...... perceptible after immersion in water, citric acid, phosphoric acid or ethanol up to 21 days (¿E... of the immersion medium (pacid or citric acid did not influence the color stability or staining susceptibility of the investigated...

  1. Weathering effects on materials from historical stained glass windows

    Directory of Open Access Journals (Sweden)

    García-Heras, M.

    2003-06-01

    Full Text Available A selection of materials (stained glasses, lead cames, support elements and putty from historical stained glass windows of different periods (13th-19th centuries have been studied. Optical microscopy, scanning electron microscopy, energy dispersive X-ray spectrometry and X-ray diffraction were used as characterization techniques. Degradation of historical stained glass windows is due to the particular chemical composition oftlie materials used for their production: stained glasses, lead network, metallic support elements and refilling putty. However, the presence of a given chemical composition is not the only factor involved in the degradation process. It is necessary the occurrence of other external factors that contribute to the development and progress of alteration problems in the materials mentioned above. The presence of gaseous pollution in the air produces a negative interaction with the surface of the stained glass windows materials. Firstly, the stained glasses and the grisailles begin a dealkalinisation process and a silica gel layer is formed during the early contact between the glasses and the wet environment. After that, insoluble salt deposits and corrosion crusts are formed as a consequence of a deeper chemical attack which results in a depolymerisation of the glass network. The lead cames and the metallic support elements are also altered by weathering. Such materials are oxidized and both pits and crusts appear on their surfaces. The transport of ions and other substances from the corrosion crusts of the metallic elements gives rise new deposits upon the stained glasses, which could intensify their own degradation processes. The putty experiments a noticeable shrinkage and cracking. Likewise, adverse environmental conditions favour the transport of putty substances towards the other materials of the stained glass window, thereby increasing the crusts thickness and adding elements that contribute to the total alteration of the

  2. Al behavior in tobacco cells by NAA and staining method

    International Nuclear Information System (INIS)

    Iikura, H.; Tanoi, K.; Nakanishi, T.M.

    2001-01-01

    To study aluminum toxicity for plant, it is important to analyze the behavior of Al in cells. The way how Al is taken up by tobacco cells through lumogallion staining method developed is presented. The fluorescence intensity from the cell was increased rapidly between 4 and 8 hours of 1 mM Al treatment. To calibrate the fluorescence intensity from Al-lumogallion complex, Al amount in the cell was determined by NAA. When the same sample was analyzed by ICP-AES, Al amounts in all the samples were 13% lower than those measured by NAA. (author)

  3. Examination of seminal stain by HPLC assay of phenolphthalein.

    Science.gov (United States)

    Yoshida, Manabu; Akane, Atsushi; Mitani, Tomoaki; Kobayashi, Tetsuya; Okii, Yutaka

    2009-04-01

    Quantitative high performance liquid chromatography (HPLC) to detect semen was investigated in this study. Briefly, 1cm of a gauze thread with a seminal stain was soaked in the reaction mixture (phenolphthalein diphosphate tetrasodium dissolved in acetate buffer) for 5-10 min, and the supernatant was analyzed by HPLC with a spectrophotometric detector. Phenolphthalein was liberated from the reagent in the presence of acid phosphatase, and the liberated phenolphthalein was detected objectively and was unaffected by blood contamination. Since liberation of phenolphthalein from the reagent occurred slightly in control negative samples, the cut-off value of the examination should be set at 1.0 microg/ml.

  4. Buffered Romanowsky-Giemsa method for formalin fixed, paraffin embedded sections: taming a traditional stain.

    Science.gov (United States)

    Stefanović, D; Samardžija, G; Redžek, A; Arnaut, M; Nikin, Z; Stefanović, M

    2017-01-01

    Romanowsky-Giemsa (RG) stains were devised during the 19th century for identifying plasmodia parasites in blood smears. Later, RG stains became standard procedures for hematology and cytology. Numerous attempts have been made to apply RG staining to formalin-fixed paraffin-embedded tissue sections, with varied success. Most published work on this topic described RG staining methods in which sections were overstained, then subjected to acid differentiation; unfortunately, the differentiation step often caused inconsistent staining outcomes. If staining is performed under optimal conditions with control of dye concentration, pH, solution temperature and staining time, no differentiation is required. We used RG and 0.002 M buffer, pH 42, for staining and washing sections. All steps were performed at room temperature. After staining and air drying, sections were washed in 96-100% ethanol to remove extraneous stain. Finally, sections were washed in xylene and mounted using DPX. Staining results were similar to routine hemalum and eosin (H & E) staining. Nuclei were blue; intensity depended largely on chromatin density. RNA-rich sites were purple. Collagen fibers, keratin, muscle cells, erythrocytes and white matter of the central nervous system were stained pinkish and reddish hues. Cartilage matrix, mast cell granules and areas of myxomatous degeneration were purple. Sulfate-rich mucins were stained pale blue, while those lacking sulfate groups were unstained. Deposits of hemosiderin, lipofuscin and melanin were greenish, and calcium deposits were blue. Helicobacter pylori bacteria were violet to purple. The advantages of the method are its close similarity to H & E staining and technical simplicity. Hemosiderin, H. pylori, mast cell granules, melanin and specific granules of different hematopoietic cells, which are invisible or barely distinguishable by H & E staining, are visualized. Other advantages over previous RG stains include shorter staining time and avoidance

  5. Reactor pressure vessel vented head

    Science.gov (United States)

    Sawabe, James K.

    1994-01-11

    A head for closing a nuclear reactor pressure vessel shell includes an arcuate dome having an integral head flange which includes a mating surface for sealingly mating with the shell upon assembly therewith. The head flange includes an internal passage extending therethrough with a first port being disposed on the head mating surface. A vent line includes a proximal end disposed in flow communication with the head internal passage, and a distal end disposed in flow communication with the inside of the dome for channeling a fluid therethrough. The vent line is fixedly joined to the dome and is carried therewith when the head is assembled to and disassembled from the shell.

  6. The Heart and Great Vessels

    Science.gov (United States)

    Onwuka, Ekene; King, Nakesha; Heuer, Eric; Breuer, Christopher

    2018-01-01

    Cardiovascular disease is the leading cause of mortality worldwide. We have made large strides over the past few decades in management, but definitive therapeutic options to address this health-care burden are still limited. Given the ever-increasing need, much effort has been spent creating engineered tissue to replaced diseased tissue. This article gives a general overview of this work as it pertains to the development of great vessels, myocardium, and heart valves. In each area, we focus on currently studied methods, limitations, and areas for future study. PMID:28289246

  7. Vessel segmentation and microaneurysm detection using discriminative dictionary learning and sparse representation.

    Science.gov (United States)

    Javidi, Malihe; Pourreza, Hamid-Reza; Harati, Ahad

    2017-02-01

    Diabetic retinopathy (DR) is a major cause of visual impairment, and the analysis of retinal image can assist patients to take action earlier when it is more likely to be effective. The accurate segmentation of blood vessels in the retinal image can diagnose DR directly. In this paper, a novel scheme for blood vessel segmentation based on discriminative dictionary learning (DDL) and sparse representation has been proposed. The proposed system yields a strong representation which contains the semantic concept of the image. To extract blood vessel, two separate dictionaries, for vessel and non-vessel, capable of providing reconstructive and discriminative information of the retinal image are learned. In the test step, an unseen retinal image is divided into overlapping patches and classified to vessel and non-vessel patches. Then, a voting scheme is applied to generate the binary vessel map. The proposed vessel segmentation method can achieve the accuracy of 95% and a sensitivity of 75% in the same range of specificity 97% on two public datasets. The results show that the proposed method can achieve comparable results to existing methods and decrease false positive vessels in abnormal retinal images with pathological regions. Microaneurysm (MA) is the earliest sign of DR that appears as a small red dot on the surface of the retina. Despite several attempts to develop automated MA detection systems, it is still a challenging problem. In this paper, a method for MA detection, which is similar to our vessel segmentation approach, is proposed. In our method, a candidate detection algorithm based on the Morlet wavelet is applied to identify all possible MA candidates. In the next step, two discriminative dictionaries with the ability to distinguish MA from non-MA object are learned. These dictionaries are then used to classify the detected candidate objects. The evaluations indicate that the proposed MA detection method achieves higher average sensitivity about 2

  8. Blood vessel damage correlated with irradiance for in vivo vascular targeted photodynamic therapy

    Science.gov (United States)

    Zhang, Jinde; Tan, Zou; Niu, Xiangyu; Lin, Linsheng; Lin, Huiyun; Li, Buhong

    2016-10-01

    Vascular targeted photodynamic therapy (V-PDT) has been widely utilized for the prevention or treatment of vascular-related diseases, including age-related macular degeneration, port-wine stains and prostate cancer. In order to quantitative assessment the blood vessel damage during V-PDT, nude mice were implanted with Titanium dorsal skin window chambers for in vivo V-PDT studies. For treatments, various irradiances including 50, 75, 100 and 200 mW/cm2 provided by a 532 nm semiconductor laser were performed with the same total light dose of 30 J/cm2 after the mice were intravenously injection of Rose Bengal for 25 mg/Kg body weight. Laser speckle imaging and microscope were used to monitor blood flow dynamics and vessel constriction during and after V-PDT, respectively. The V-PDT induced vessel damages between different groups were compared. The results show that significant difference in blood vessel damage was found between the lower irradiances (50, 75 and 100 mW/cm2) and higher irradiance (200 mW/cm2), and the blood vessel damage induced by V-PDT is positively correlated with irradiance. This study implies that the optimization of irradiance is required for enhancing V-PDT therapeutic efficiency.

  9. Improving dense conditional random field for retinal vessel segmentation by discriminative feature learning and thin-vessel enhancement.

    Science.gov (United States)

    Zhou, Lei; Yu, Qi; Xu, Xun; Gu, Yun; Yang, Jie

    2017-09-01

    As retinal vessels in color fundus images are thin and elongated structures, standard pairwise based random fields, which always suffer the "shrinking bias" problem, are not competent for such segmentation task. Recently, a dense conditional random field (CRF) model has been successfully used in retinal vessel segmentation. Its corresponding energy function is formulated as a linear combination of several unary features and a pairwise term. However, the hand-crafted unary features can be suboptimal in terms of linear models. Here we propose to learn discriminative unary features and enhance thin vessels for pairwise potentials to further improve the segmentation performance. Our proposed method comprises four main steps: firstly, image preprocessing is applied to eliminate the strong edges around the field of view (FOV) and normalize the luminosity and contrast inside FOV; secondly, a convolutional neural network (CNN) is properly trained to generate discriminative features for linear models; thirdly, a combo of filters are applied to enhance thin vessels, reducing the intensity difference between thin and wide vessels; fourthly, by taking the discriminative features for unary potentials and the thin-vessel enhanced image for pairwise potentials, we adopt the dense CRF model to achieve the final retinal vessel segmentation. The segmentation performance is evaluated on four public datasets (i.e. DRIVE, STARE, CHASEDB1 and HRF). Experimental results show that our proposed method improves the performance of the dense CRF model and outperforms other methods when evaluated in terms of F1-score, Matthews correlation coefficient (MCC) and G-mean, three effective metrics for the evaluation of imbalanced binary classification. Specifically, the F1-score, MCC and G-mean are 0.7942, 0.7656, 0.8835 for the DRIVE dataset respectively; 0.8017, 0.7830, 0.8859 for STARE respectively; 0.7644, 0.7398, 0.8579 for CHASEDB1 respectively; and 0.7627, 0.7402, 0.8812 for HRF respectively

  10. Authenticity screening of stained glass windows using optical spectroscopy

    Science.gov (United States)

    Meulebroeck, Wendy; Wouters, Hilde; Nys, Karin; Thienpont, Hugo

    2016-11-01

    Civilized societies should safeguard their heritage as it plays an important role in community building. Moreover, past technologies often inspire new technology. Authenticity is besides conservation and restoration a key aspect in preserving our past, for example in museums when exposing showpieces. The classification of being authentic relies on an interdisciplinary approach integrating art historical and archaeological research complemented with applied research. In recent decades analytical dating tools are based on determining the raw materials used. However, the traditional applied non-portable, chemical techniques are destructive and time-consuming. Since museums oftentimes only consent to research actions which are completely non-destructive, optical spectroscopy might offer a solution. As a case-study we apply this technique on two stained glass panels for which the 14th century dating is nowadays questioned. With this research we were able to identify how simultaneous mapping of spectral signatures measured with a low cost optical spectrum analyser unveils information regarding the production period. The significance of this research extends beyond the re-dating of these panels to the 19th century as it provides an instant tool enabling immediate answering authenticity questions during the conservation process of stained glass, thereby providing the necessary data for solving deontological questions about heritage preservation.

  11. Color stability of ceramic brackets immersed in potentially staining solutions

    Directory of Open Access Journals (Sweden)

    Bruna Coser Guignone

    2015-08-01

    Full Text Available OBJECTIVE: To assess the color stability of five types of ceramic brackets after immersion in potentially staining solutions.METHODS: Ninety brackets were divided into 5 groups (n = 18 according to brackets commercial brands and the solutions in which they were immersed (coffee, red wine, coke and artificial saliva. The brackets assessed were Transcend (3M/Unitek, Monrovia, CA, USA, Radiance (American Orthodontics, Sheboygan, WI, USA, Mystique (GAC International Inc., Bohemia, NY, USA and Luxi II (Rocky Mountain Orthodontics, Denver, CO, USA. Chromatic changes were analyzed with the aid of a reflectance spectrophotometer and by visual inspection at five specific time intervals. Assessment periods were as received from the manufacturer (T0, 24 hours (T1, 72 hours (T2, as well as 7 days (T3 and 14 days (T4 of immersion in the aforementioned solutions. Results were submitted to statistical analysis with ANOVA and Bonferroni correction, as well as to a multivariate profile analysis for independent and paired samples with significance level set at 5%.RESULTS: The duration of the immersion period influenced color alteration of all tested brackets, even though these changes could not always be visually observed. Different behaviors were observed for each immersion solution; however, brackets immersed in one solution progressed similarly despite minor variations.CONCLUSIONS: Staining became more intense over time and all brackets underwent color alterations when immersed in the aforementioned solutions.

  12. Authenticity screening of stained glass windows using optical spectroscopy.

    Science.gov (United States)

    Meulebroeck, Wendy; Wouters, Hilde; Nys, Karin; Thienpont, Hugo

    2016-11-24

    Civilized societies should safeguard their heritage as it plays an important role in community building. Moreover, past technologies often inspire new technology. Authenticity is besides conservation and restoration a key aspect in preserving our past, for example in museums when exposing showpieces. The classification of being authentic relies on an interdisciplinary approach integrating art historical and archaeological research complemented with applied research. In recent decades analytical dating tools are based on determining the raw materials used. However, the traditional applied non-portable, chemical techniques are destructive and time-consuming. Since museums oftentimes only consent to research actions which are completely non-destructive, optical spectroscopy might offer a solution. As a case-study we apply this technique on two stained glass panels for which the 14 th century dating is nowadays questioned. With this research we were able to identify how simultaneous mapping of spectral signatures measured with a low cost optical spectrum analyser unveils information regarding the production period. The significance of this research extends beyond the re-dating of these panels to the 19 th century as it provides an instant tool enabling immediate answering authenticity questions during the conservation process of stained glass, thereby providing the necessary data for solving deontological questions about heritage preservation.

  13. Coproduction of detergent compatible bacterial enzymes and stain removal evaluation.

    Science.gov (United States)

    Niyonzima, Francois N; More, Sunil S

    2015-10-01

    Most of the detergents that are presently produced contain the detergent compatible enzymes to improve and accelerate the washing performance by removing tough stains. The process is environment friendly as the use of enzymes in the detergent formulation reduces the utilization of toxic detergent constituents. The current trend is to use the detergent compatible enzymes that are active at low and ambient temperature in order to save energy and maintain fabric quality. As the detergent compatible bacterial enzymes are used together in the detergent formulation, it is important to co-produce the detergent enzymes in a single fermentation medium as the enzyme stability is assured, and production cost gets reduced enormously. The review reports on the production, purification, characterization and application of detergent compatible amylases, lipases, and proteases are available. However, there is no specific review or minireview on the concomitant production of detergent compatible amylases, lipases, and proteases. In this minireview, the coproduction of detergent compatible enzymes by bacterial species, enzyme stability towards detergents and detergent components, and stain release analysis were discussed. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Visualizing peripheral nerve regeneration by whole mount staining.

    Directory of Open Access Journals (Sweden)

    Xin-peng Dun

    Full Text Available Peripheral nerve trauma triggers a well characterised sequence of events both proximal and distal to the site of injury. Axons distal to the injury degenerate, Schwann cells convert to a repair supportive phenotype and macrophages enter the nerve to clear myelin and axonal debris. Following these events, axons must regrow through the distal part of the nerve, re-innervate and finally are re-myelinated by Schwann cells. For nerve crush injuries (axonotmesis, in which the integrity of the nerve is maintained, repair may be relatively effective whereas for nerve transection (neurotmesis repair will likely be very poor as few axons may be able to cross between the two parts of the severed nerve, across the newly generated nerve bridge, to enter the distal stump and regenerate. Analysing axon growth and the cell-cell interactions that occur following both nerve crush and cut injuries has largely been carried out by staining sections of nerve tissue, but this has the obvious disadvantage that it is not possible to follow the paths of regenerating axons in three dimensions within the nerve trunk or nerve bridge. To try and solve this problem, we describe the development and use of a novel whole mount staining protocol that allows the analysis of axonal regeneration, Schwann cell-axon interaction and re-vascularisation of the repairing nerve following nerve cut and crush injuries.

  15. Stained glasses under the nuclear microprobe: A window into history

    Energy Technology Data Exchange (ETDEWEB)

    Vilarigues, M. [Dep. de Conservacao e Restauro and R and D Unit Vidro e da Ceramica Para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal)], E-mail: mgv@fct.unl.pt; Fernandes, P. [Dep. de Conservacao e Restauro and R and D Unit Vidro e da Ceramica Para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal); Alves, L.C.; Silva, R.C. da [Dep. Fisica, LFI, ITN, E.N.10, 2686-953 Sacavem (Portugal)

    2009-06-15

    Stained glass fragments from the 15th, 16th and 20th centuries, belonging to Mosteiro de Santa Maria da Vitoria, Batalha (Portugal), were characterised non-destructively in a nuclear microprobe. The work aimed at finding the composition of the glasses and glass paintings and relating these with the corresponding production periods. The elemental compositions of the glass fragments were obtained by means of scanning micro-beam Particle Induced X-ray Emission ({mu}-PIXE) spectrometry in selected cross-sections. These were complemented by micro X-Ray fluorescence spectrometry. Characterisation of colour was performed by optical absorption spectroscopy in the UV-vis range, while the corrosion products were identified by optical microscopy and {mu}-FTIR (Fourier Transform Infra Red) spectroscopy in combination with the data generated by {mu}-PIXE. Nuclear microprobe analysis allowed unveiling the compositions and structures, in particular of glass paintings and corrosion products. While it is not surprising that Fe, Cu and Pb were the main elements identified in the grisaille paintings of all studied periods, as well as Ag and Cu found in the glasses decorated with yellow silver painting, their distribution gave important clues on the materials and techniques used to manufacture these stained glasses. Furthermore, it allowed establishing a definite relation between the compositions found and the periods of production, with the added bonus of correctly reassigning the manufacturing period of some samples.

  16. STAINING SECTIONS OF WATER-MISCIBLE RESINS .1. EFFECTS OF THE MOLECULAR-SIZE OF THE STAIN, AND OF RESIN CROSS-LINKING, ON THE STAINING OF GLYCOL METHACRYLATE EMBEDDED TISSUES

    NARCIS (Netherlands)

    GERRITS, PO; HOROBIN, RW; WRIGHT, DJ

    1990-01-01

    Penetration of hydrophilic acid and basic dyes into sections cut from glycol methacrylate (GMA)-embedded tissues was studied; as were the effects on such staining of superficial coatings of thin layers of GMA. Dye size was a major factor in controlling penetration of resin and staining of tissues.

  17. Submerged demineralizer system vessel shipment report

    International Nuclear Information System (INIS)

    Quinn, G.J.; Henrie, J.O.; Greenborg, J.

    1984-06-01

    Vessels containing zeolites and absorbed fission products from processing accident-generated water at Three Mile Island through the Submerged Demineralizer System were found to generate radiolytic hydrogen and oxygen gases. In some vessels with high curie contents, gas generation during shipment could have resulted in flammable gas concentrations exceeding federal limits for radioactive material shipments. Tests of a catalyst bed in the vessel demonstrated that recombination of the gases back into water would permit safe shipment of the sealed vessels. Catalyst was loaded into an available screen assembly in each vessel. Vessel pressure monitoring ensured that net gas generation had stopped and that hydrogen and oxygen concentrations were kept below flammable limits. All shipments complied with federal regulations

  18. Effectiveness of clean-up procedures on stain susceptibility of different orthodontic adhesives

    Directory of Open Access Journals (Sweden)

    Swati Pundlik Mane

    2014-01-01

    Conclusion: Chemical-cure adhesive showed higher stain susceptibility than light-cure adhesive in all clean-up procedures. Both adhesives would show less stain susceptibility with polishing step with rubber cup and pumice.

  19. Exponential Stabilization of an Underactuated Surface Vessel

    Directory of Open Access Journals (Sweden)

    Kristin Y. Pettersen

    1997-07-01

    Full Text Available The paper shows that a large class of underactuated vehicles cannot be asymptotically stabilized by either continuous or discontinuous state feedback. Furthermore, stabilization of an underactuated surface vessel is considered. Controllability properties of the surface vessels is presented, and a continuous periodic time-varying feedback law is proposed. It is shown that this feedback law exponentially stabilizes the surface vessel to the origin, and this is illustrated by simulations.

  20. Computerized reactor pressure vessel materials information system

    International Nuclear Information System (INIS)

    Strosnider, J.; Monserrate, C.; Kenworthy, L.D.; Tether, C.D.

    1980-10-01

    A computerized information system for storage and retrieval of reactor pressure vessel materials data was established, as part of Task Action Plan A-11, Reactor Vessel Materials Toughness. Data stored in the system are necessary for evaluating the resistance of reactor pressure vessels to flaw-induced fracture. This report includes (1) a description of the information system; (2) guidance on accessing the system; and (3) a user's manual for the system

  1. Underwater robot system for reactor vessel

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Soo; Kim, Tae Won; Lee, Sung Uk; Jeong, Kyung Min [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    It is dangerous to work inside reactor vessel because of high radioactivity. So robot system is necessary to work inside reactor vessel instead of workers. And robot also has advantage of mobility over conventional equipment which has limitation of the range of accessibility. In this paper, we describe design consideration and criteria of robot system for reactor vessel, and component of developed system. Reliability, usability and convenience of robot system were considered to design and fabrication.

  2. Underwater robot system for reactor vessel

    International Nuclear Information System (INIS)

    Choi, Young Soo; Kim, Tae Won; Lee, Sung Uk; Jeong, Kyung Min

    2012-01-01

    It is dangerous to work inside reactor vessel because of high radioactivity. So robot system is necessary to work inside reactor vessel instead of workers. And robot also has advantage of mobility over conventional equipment which has limitation of the range of accessibility. In this paper, we describe design consideration and criteria of robot system for reactor vessel, and component of developed system. Reliability, usability and convenience of robot system were considered to design and fabrication

  3. Diagnostic utility of melanin production by fungi: Study on tissue sections and culture smears with Masson-Fontana stain

    Directory of Open Access Journals (Sweden)

    Challa Sundaram

    2014-01-01

    Full Text Available Background: Dematiaceous fungi appear brown in tissue section due to melanin in their cell walls. When the brown color is not seen on routine H and E and culture is not available, differentiation of dematiaceous fungi from other fungi is difficult on morphology alone. Aims and Objective: To study if melanin production by dematiaceous fungi can help differentiate them from other types of fungi. Materials and Methods: Fifty tissue sections of various fungal infections and 13 smears from cultures of different species of fungi were stained with Masson Fontana stain to assess melanin production. The tissue sections included biopsies from 26 culture-proven fungi and 24 biopsies of filamentous fungi diagnosed on morphology alone with no culture confirmation. Results: All culture-proven dematiaceous fungi and Zygomycetes showed strong positivity in sections and culture smears. Aspergillus sp showed variable positivity and intensity. Cryptococcus neoformans showed strong positivity in tissue sections and culture smears. Tissue sections of septate filamentous fungi (9/15, Zygomycetes (4/5, and fungi with both hyphal and yeast morphology (4/4 showed positivity for melanin. The septate filamentous fungi negative for melanin were from biopsy samples of fungal sinusitis including both allergic and invasive fungal sinusitis and colonizing fungal balls. Conclusion: Melanin is produced by both dematiaceous and non-dematiaceous fungi. Masson-Fontana stain cannot reliably differentiate dematiaceous fungi from other filamentous fungi like Aspergillus sp; however, absence of melanin in the hyphae may be used to rule out dematiaceous fungi from other filamentous fungi. In the differential diagnosis of yeast fungi, Cryptococcus sp can be differentiated from Candida sp by Masson-Fontana stain in tissue sections.

  4. Nd:YAG laser combined with gold nanorods for potential application in port-wine stains: an in vivo study

    Science.gov (United States)

    Xing, Linzhuang; Chen, Bin; Li, Dong; Wu, Wenjuan; Wang, Guoxiang

    2017-11-01

    Neodymium:yttrium aluminum garnet (Nd:YAG) lasers exhibit considerable potential for treating deeply buried port-wine stains. However, the application of Nd:YAG laser is limited by its weak absorption to blood. This in vivo study tested the efficacy and safety of utilizing thiol-terminated methoxypolyethylene glycol-modified gold nanorods (PEG-GNRs) to enhance the absorption of Nd:YAG laser to blood. Mouse mesentery and dorsal skinfold chamber (DSC) model were prepared to analyze the thermal responses of a single venule without anatomic structures, as well as blood vessels in the complex structure of the skin, to laser light. After the injection of 0.44 mg of PEG-GNRs, the required threshold density of laser energy for blood coagulation and complete vasoconstriction decreased from 24 to 18 J/cm2 in the mesentery model and from 36 to 31 J/cm2 in the DSC model. The laser pulse required for blood coagulation and complete vasoconstriction decreased by 67.75% and 62.25% on average in the mesentery model and by 67.55% and 54.45% on average in the DSC model. Histological and histochemical results confirmed that PEG-GNRs are nontoxic in the entire mouse life span. Therefore, combining PEG-GNRs with Nd:YAG laser may be effective and safe for inducing an obvious thermal response of blood vessels under low energy density and minimal pulse conditions.

  5. Maternal and fetal characteristics associated with meconium-stained amniotic fluid

    DEFF Research Database (Denmark)

    Balchin, Imelda; Whittaker, John C; Lamont, Ronald F

    2011-01-01

    To estimate the rates of meconium-stained amniotic fluid (AF) and adverse outcome in relation to gestational age and racial group, and to investigate the predictors of meconium-stained AF.......To estimate the rates of meconium-stained amniotic fluid (AF) and adverse outcome in relation to gestational age and racial group, and to investigate the predictors of meconium-stained AF....

  6. Indirect immunofluorescence staining of Chlamydia trachomatis inclusions in microculture plates with monoclonal antibodies.

    Science.gov (United States)

    Zapata, M; Chernesky, M; Mahony, J

    1984-06-01

    Indirect immunofluorescence (IF) staining, using a monoclonal antibody, detected two- to fourfold more inclusions than did iodine staining. Of 274 clinical specimens, 53 (19.3%) were positive by IF on passage 1 as compared with 33 (12%) by iodine staining (P less than 0.005). IF-stained inclusions in McCoy cells in the bottom of microculture wells were readily viewed with a long-focal-length objective at a magnification of 250 X.

  7. Indirect immunofluorescence staining of Chlamydia trachomatis inclusions in microculture plates with monoclonal antibodies.

    OpenAIRE

    Zapata, M; Chernesky, M; Mahony, J

    1984-01-01

    Indirect immunofluorescence (IF) staining, using a monoclonal antibody, detected two- to fourfold more inclusions than did iodine staining. Of 274 clinical specimens, 53 (19.3%) were positive by IF on passage 1 as compared with 33 (12%) by iodine staining (P less than 0.005). IF-stained inclusions in McCoy cells in the bottom of microculture wells were readily viewed with a long-focal-length objective at a magnification of 250 X.

  8. How to replace a reactor pressure vessel

    International Nuclear Information System (INIS)

    Huber, R.

    1996-01-01

    A potential life extending procedure for a nuclear reactor after, say, 40 years of service life, might in some circumstances be the replacement of the reactor pressure vessel. Neutron induced degradation of the vessel might make replacement by one of a different material composition desirable, for example. Although the replacement of heavy components, such as steam generators, has been possible for many years, the pressure vessel presents a much more demanding task if only because it is highly irradiated. Some preliminary feasibility studies by Siemens are reported for the two removal strategies that might be considered. These are removal of the entire pressure vessel in one piece and dismantling it into sections. (UK)

  9. Safety vessels for explosive fusion reactor

    International Nuclear Information System (INIS)

    Mineev, V.

    1994-01-01

    The failure of several types of geometrically similar cylindrical and spherical steel and glass fibers vessels filled with water or air was investigated when an explosive charge of TNT was detonated in the center. Vessels had radius 50-1000 mm, thickness of walls 2-20%. The detonation on TNT imitated energy release. The parameter: K = M/mf is a measure of the strength of the vessel where M is the mass of the vessel, and mf is the mass of TNT for which the vessel fails. This demanded 2-4 destroyed and nondestroyed shots. It may be showed that: K=A/σ f where σ f is the fracture stress of the material vessel, and A = const = F(energy TNT, characteristic of elasticity of vessel material). The chief results are the following: (1) A similar increase in the geometrical dimensions of steel vessels by a factor of 10 leads to the increase of parameter K in about 5 times and to decrease of failure deformation in 7 times (scale effect). (2) For glass fibers, scale effect is absent. (3) This problem is solved in terms of theory energetic scale effect. (4) The concept of TNT equivalent explosive makes it possible to use these investigations to evaluate the response of safety vessels for explosive fusion reactor

  10. Detection of blood vessels on coronary cineangiograms

    International Nuclear Information System (INIS)

    Yanagihara, Yosio; Sugahara, Tetsuo; Uyama, Chikao

    1988-01-01

    To determine the most suitable filter for measuring blood vessel width on a coronary cineagiogram, several sizes of vessel phantoms were taken under different energies and contrast substance densities on cine film and the vessel widths were calculated by using several edge detection filters. Among the filters, the entropy and Gaussian filters were found to be twice as accurate as the derivative filters. The entropy filter was applied to one frame of a coronary angiogram, and the detected vessel edges were as accurate as the determined by a radiologist. This filter can be applied to coronary cineangiograms, including stenosed sites. (author)

  11. Stabilizer for reactor pressure vessel

    International Nuclear Information System (INIS)

    Nakajima, Masataka.

    1991-01-01

    A plurality of flush springs and sleeves are disposed to a rod to be screw-coupled to a yoke disposed between gusset side walls. A vibration energy dissipation mechanism due to resiliently plastic deformation of metal is disposed between the gusset side wall and the sleeve of the rod. When earthquakes should occur and the distance between the gusset side wall and the sleeve is changed undergoing seismic input, the vibration energy is dissipated by the resilient plastic deformation of the vibration energy dissipation mechanism. The seismic response of the pressure vessel system is thus decreased to improve seismic resistivity. The reactor safety and reliability can be ensured. It is not necessary to strengthen supports for pipeline systems, and increase of the cost, including design and manufacture, can be avoided while giving no effects on the layout for the upper portion of reactor shielding walls. (N.H.)

  12. Grounding Damage to Conventional Vessels

    DEFF Research Database (Denmark)

    Lützen, Marie; Simonsen, Bo Cerup

    2003-01-01

    The present paper is concerned with rational design of conventional vessels with regard to bottom damage generated in grounding accidents. The aim of the work described here is to improve the design basis, primarily through analysis of new statistical data for grounding damage. The current...... regulations for design of bottom compartment layout with regard to grounding damages are largely based on statistical damage data. New and updated damage statistics holding 930 grounding accident records has been investigated. The bottom damage statistics is compared to current regulations for the bottom...... compartment layout, in an attempt to determine the probability of exceeding the design requirements. Distributions for the extent of damage, such as damage length, height and width, are determined. Furthermore, attempts are made at identifying the governing grounding scenarios and deriving a formula...

  13. Quantum electrodynamics of strong fields

    International Nuclear Information System (INIS)

    Greiner, W.

    1983-01-01

    Quantum Electrodynamics of Strong Fields provides a broad survey of the theoretical and experimental work accomplished, presenting papers by a group of international researchers who have made significant contributions to this developing area. Exploring the quantum theory of strong fields, the volume focuses on the phase transition to a charged vacuum in strong electric fields. The contributors also discuss such related topics as QED at short distances, precision tests of QED, nonperturbative QCD and confinement, pion condensation, and strong gravitational fields In addition, the volume features a historical paper on the roots of quantum field theory in the history of quantum physics by noted researcher Friedrich Hund

  14. Vegetable cells in Papanicolaou-stained cervical smears.

    Science.gov (United States)

    Rivasi, Francesco; Tosi, Giovanni; Ruozi, Barbara; Curatola, Carlo

    2006-01-01

    Vegetable cells are unusual findings in Papanicolaou-stained cervical smears; these structures could be wrongly mistaken for abnormal human cells, worm eggs, or spores by a cytologist encountering the possibility of meeting those elements in cytological analysis. Five cervicovaginal smears showing similar vegetable cells have been detected over a 3-yr period (2002-2004) in the course of a population screening program for cancer of the uterine cervix in Modena (Italy) involving 32,500 women. According to the clinical histories of the patients, the vaginal pharmaceutical drugs or appliances used were of different types: vaginal lavages, pessaries, and vaginal creams. Following a careful investigation, the only substance that can lead to vegetal elements has been identified as polysaccharide galactomannan, which is one of the excipient present in the drugs used. The authors have identified the origin of these contaminants and the means of pollution, using cytological and pharmaceutical investigation.

  15. Homogeneously staining regions (HSR) in a human malignant melanoma.

    Science.gov (United States)

    Brieux de Salum, S; Slavutsky, I; Besuschio, S; Pavlovsky, A A

    1984-01-01

    A case of nodular malignant melanoma (level V of Clark's classification) with homogeneously staining regions (HSR) on the long arm of one chromosome #2 is described. Ultrastructural observation of melanosomic and promelanosomic granules near Golgi's vesicles confirmed the histologic diagnosis. Chromosome analysis was performed on nine metaphases from a bone marrow sample and 76 metaphases from culture of the malignant skin tumor. G-banding revealed the presence of a clone with trisomy #8 and another cell line with the HSR marker. This is the first report of HSR in human melanoma cells. As HSR has been found only in malignant cells, we believe that among the many factors that influence the patients' clinical evolution and poor response to treatment, the genic imbalance is of the utmost importance.

  16. Fat tissue staining and photodynamic/photothermal effects

    Science.gov (United States)

    Tuchin, Valery V.; Altshuler, Gregory B.; Yanina, Irina Yu.; Kochubey, Vyacheslav I.; Simonenko, Georgy V.

    2010-02-01

    Cellulite is considered as a disease of the subcutaneous fat layer that appears mostly in women and consists of changes in fat cell accumulation together with disturbed lymphatic drainage, affecting the external appearance of the skin. The photodynamic and selective photothermal treatments may provide reduction the volume of regional or sitespecific accumulations of subcutaneous adipose tissue on the cellular level. We hypothesize that light irradiation of stained fat tissue at selected temperature leads to fat cell lypolytic activity (the enhancement of lipolysis of cell triglycerides due to expression of lipase activity and cell release of free fat acids (FFAs) due to temporal cell membrane porosity), and cell killing due to apoptosis caused by the induced fat cell stress and/or limited cell necrosis.

  17. Age estimation of blood stains by hemoglobin derivative determination using reflectance spectroscopy

    NARCIS (Netherlands)

    Bremmer, Rolf H.; Nadort, Annemarie; van Leeuwen, Ton G.; van Gemert, Martin J. C.; Aalders, Maurice C. G.

    2011-01-01

    Blood stains can be crucial in reconstructing crime events. However, no reliable methods are currently available to establish the age of a blood stain on the crime scene. We show that determining the fractions of three hemoglobin derivatives in a blood stain at various ages enables relating these

  18. A Comparison of Heat versus Methanol Fixation for Gram Staining Bacteria

    Science.gov (United States)

    Minnerath, Jeanne M.; Roland, Jenna M.; Rossi, Lucas C.; Weishalla, Steven R.; Wolf, Melissa M.

    2009-01-01

    Gram staining bacteria is a fundamental technique introduced in general biology and microbiology laboratory courses. Two common problems students encounter when Gram staining bacteria are (1) having a difficult time locating bacterial cells on the microscope slide and (2) over-decolorizing bacterial cells during the staining procedure such that…

  19. Combined beta-galactosidase and immunogold/silver staining for immunohistochemistry and DNA in situ hybridization

    NARCIS (Netherlands)

    van den Brink, W.; van der Loos, C.; Volkers, H.; Lauwen, R.; van den Berg, F.; Houthoff, H. J.; Das, P. K.

    1990-01-01

    A combination of beta-galactosidase enzyme and the immunogold/silver staining method was studied for evaluation of double-staining experiments. Applications are shown for immunohistochemical double staining using two monoclonal antibodies and for combined immunohistochemistry and DNA in situ

  20. Digital simulation of staining in histopathology multispectral images: enhancement and linear transformation of spectral transmittance.

    Science.gov (United States)

    Bautista, Pinky A; Yagi, Yukako

    2012-05-01

    Hematoxylin and eosin (H&E) stain is currently the most popular for routine histopathology staining. Special and/or immuno-histochemical (IHC) staining is often requested to further corroborate the initial diagnosis on H&E stained tissue sections. Digital simulation of staining (or digital staining) can be a very valuable tool to produce the desired stained images from the H&E stained tissue sections instantaneously. We present an approach to digital staining of histopathology multispectral images by combining the effects of spectral enhancement and spectral transformation. Spectral enhancement is accomplished by shifting the N-band original spectrum of the multispectral pixel with the weighted difference between the pixel's original and estimated spectrum; the spectrum is estimated using M transformed to the spectral configuration associated to its reaction to a specific stain by utilizing an N × N transformation matrix, which is derived through application of least mean squares method to the enhanced and target spectral transmittance samples of the different tissue components found in the image. Results of our experiments on the digital conversion of an H&E stained multispectral image to its Masson's trichrome stained equivalent show the viability of the method.

  1. 19 CFR 10.52 - Painted, colored or stained glass windows for religious institutions.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Painted, colored or stained glass windows for.... General Provisions Works of Art § 10.52 Painted, colored or stained glass windows for religious institutions. When painted, colored, or stained glass windows or parts thereof, are claimed free of duty under...

  2. Surface discoloration of composite resins: Effects of staining and bleaching

    Science.gov (United States)

    Poggio, Claudio; Beltrami, Riccardo; Scribante, Andrea; Colombo, Marco; Chiesa, Marco

    2012-01-01

    Background: The purpose of this in vitro study was to evaluate surface discoloration of three microhybrid composite resins (Esthet•X HD, Clearfil AP-X, Gradia Direct) and five nanohybrid composite resins (Ceram•X, GC Kalore, G-aenial, Grandio, GrandioSO), after staining and bleaching procedures. Materials and Methods: The composite resins were polymerized with a curing light (Celalux II, Voco, Cuxhaven, Germany) into 160 silicon molds (6,4 mm in diameter and 2 mm in thickness) to obtain identical specimens. Twenty samples for each composite resin were prepared. The specimens were polished using an automated polishing machine with the sequence of 600-, 800-, 1000-grit abrasive paper under water irrigation. The specimens were immersed in tea and distilled water: the specimens were dipped for 20 min, once a day (every 24 h), for 14 days into the drinks. The specimens were then bleached with carbamide peroxide at 17% (Perfect Bleach-Voco). The color of specimens was measured with a spectrophotometer according to the CIE L*a*b* system after light-polymerization of composite resin specimens, after 7 days, after 14 days, and after bleaching. The color difference h index (DEab*) between each measurement was calculated. Statistical analysis was made using analysis of variance (ANOVA). Results: All specimens showed a significant increase in staining with a similar trend and no significant differences between microhybrid and nanohybrid composite resins. After whitening procedures, materials tested showed both significant and unsignificant differences of the h index. Conclusions: Microhybrid and nanohybrid composite resins had similar in vitro surface discoloration in tea. After bleaching, discoloration was removed from some composite resins tested. PMID:23559921

  3. Surface discoloration of composite resins: Effects of staining and bleaching

    Directory of Open Access Journals (Sweden)

    Claudio Poggio

    2012-01-01

    Full Text Available Background: The purpose of this in vitro study was to evaluate surface discoloration of three microhybrid composite resins (Esthet·X HD, Clearfil AP-X, Gradia Direct and five nanohybrid composite resins (Ceram·X, GC Kalore, G-aenial, Grandio, GrandioSO, after staining and bleaching procedures. Materials and Methods: The composite resins were polymerized with a curing light (Celalux II, Voco, Cuxhaven, Germany into 160 silicon molds (6,4 mm in diameter and 2 mm in thickness to obtain identical specimens. Twenty samples for each composite resin were prepared. The specimens were polished using an automated polishing machine with the sequence of 600-, 800-, 1000-grit abrasive paper under water irrigation. The specimens were immersed in tea and distilled water: the specimens were dipped for 20 min, once a day (every 24 h, for 14 days into the drinks. The specimens were then bleached with carbamide peroxide at 17% (Perfect Bleach-Voco. The color of specimens was measured with a spectrophotometer according to the CIE LFNx01aFNx01bFNx01 system after light-polymerization of composite resin specimens, after 7 days, after 14 days, and after bleaching. The color difference h index (DE abFNx01 between each measurement was calculated. Statistical analysis was made using analysis of variance (ANOVA. Results: All specimens showed a significant increase in staining with a similar trend and no significant differences between microhybrid and nanohybrid composite resins. After whitening procedures, materials tested showed both significant and unsignificant differences of the h index. Conclusions: Microhybrid and nanohybrid composite resins had similar in vitro surface discoloration in tea. After bleaching, discoloration was removed from some composite resins tested.

  4. Surface discoloration of composite resins: Effects of staining and bleaching.

    Science.gov (United States)

    Poggio, Claudio; Beltrami, Riccardo; Scribante, Andrea; Colombo, Marco; Chiesa, Marco

    2012-09-01

    The purpose of this in vitro study was to evaluate surface discoloration of three microhybrid composite resins (Esthet•X HD, Clearfil AP-X, Gradia Direct) and five nanohybrid composite resins (Ceram•X, GC Kalore, G-aenial, Grandio, GrandioSO), after staining and bleaching procedures. The composite resins were polymerized with a curing light (Celalux II, Voco, Cuxhaven, Germany) into 160 silicon molds (6,4 mm in diameter and 2 mm in thickness) to obtain identical specimens. Twenty samples for each composite resin were prepared. The specimens were polished using an automated polishing machine with the sequence of 600-, 800-, 1000-grit abrasive paper under water irrigation. The specimens were immersed in tea and distilled water: the specimens were dipped for 20 min, once a day (every 24 h), for 14 days into the drinks. The specimens were then bleached with carbamide peroxide at 17% (Perfect Bleach-Voco). The color of specimens was measured with a spectrophotometer according to the CIE L(*)a(*)b(*) system after light-polymerization of composite resin specimens, after 7 days, after 14 days, and after bleaching. The color difference h index (DEab(*)) between each measurement was calculated. Statistical analysis was made using analysis of variance (ANOVA). All specimens showed a significant increase in staining with a similar trend and no significant differences between microhybrid and nanohybrid composite resins. After whitening procedures, materials tested showed both significant and unsignificant differences of the h index. Microhybrid and nanohybrid composite resins had similar in vitro surface discoloration in tea. After bleaching, discoloration was removed from some composite resins tested.

  5. Evaluating Corneal Fluorescein Staining Using a Novel Automated Method.

    Science.gov (United States)

    Amparo, Francisco; Wang, Haobing; Yin, Jia; Marmalidou, Anna; Dana, Reza

    2017-05-01

    To evaluate interobserver concordance in measured corneal fluorescein staining (CFS) using the National Eye Institute/Industry (NEI) grading scale and the Corneal Fluorescein Staining Index (CFSi), a computer-assisted, objective, centesimal scoring system. We conducted a study to evaluate CFS in clinical photographs of patients with corneal epitheliopathy. One group of clinicians graded CFS in the images using the NEI while a second group applied the CFSi. We evaluated the level of interobserver agreement and differences among CFS scores with each method, level of correlation between the two methods, and distribution of cases based on the CFS severity assigned by each method. The level of interobserver agreement was 0.65 (P < 0.001) with the NEI, and 0.99 (P < 0.001) with the CFSi. There were statistically significant differences among clinicians' measurements obtained with the NEI (P < 0.001), but not with the CFSi (P = 0.78). There was a statistically significant correlation between the CFS scores obtained with the two methods (R = 0.72; P < 0.001). The NEI scale allocated the majority of cases (65%) within the higher quartile in the scale's severity (12-15/15). In contrast, the CFSi allocated the majority of cases (61%) within the lower quartile in the scale's severity (0-25/100). The CFSi is easy to implement, provides higher interobserver consistency, and due to its continuous score can discriminate smaller differences in CFS. Reproducibility of the computer-based system is higher and, interestingly, the system allocates cases of epitheliopathy in different severity categories than clinicians do. The CFSi can be an alternative for objective CFS evaluation in the clinic and in clinical trials.

  6. Inspection technology of Korean standard Reactor vessel

    International Nuclear Information System (INIS)

    Doh, Euisoon

    2002-01-01

    This paper is for the inspection technology of Korean standard Reactor vessel. KPS performed Korean standard Reactor vessel inspection for a part of Yonggwang unit 5 and full inspection of Yonggwang unit 6 on November in 2001. Korean standard Reactor vessel is different from Westinghouse and Framatome plants in design and material. Understanding design, structure and material is very important to prepare and to perform Reactor vessel inspection. Korean standard Reactor vessel has 6 Stabilizer lugs, 6 Core stop lugs and one Flow Baffle around Lower head to Bottom head weld(G4). They make very difficult to perform scanning of G4 by transducers and to install Lower Platform of robot system. Korean standard Reactor vessel has 2 Outlet Nozzles, 4 Inlet Nozzles and small curvature of Inner Radius regions. That small curvature's Inner Radius region needs a special technology to perform the area more than 90% of whole examination volume. The most significant difference of Korean standard Reactor vessel is that it does not have Safe End region because both of Reactor vessel and main reactor coolant system piping are carbon steel. Therefore, the technology for this nozzle to piping weld is very unique to be compared with other Westinghouse or Framatome plants. Described above, the inspection technology of Korean standard Reactor Vessel is very different from other Reactor Vessel due to different internal structure and material. The company which performs this 10 years ISI in future will need much investigation of structure and material to succeed in Reactor vessel inspection of Korean standard plant

  7. Strong WW Interaction at LHC

    Energy Technology Data Exchange (ETDEWEB)

    Pelaez, Jose R

    1998-12-14

    We present a brief pedagogical introduction to the Effective Electroweak Chiral Lagrangians, which provide a model independent description of the WW interactions in the strong regime. When it is complemented with some unitarization or a dispersive approach, this formalism allows the study of the general strong scenario expected at the LHC, including resonances.

  8. Strong-back safety latch

    International Nuclear Information System (INIS)

    DeSantis, G.N.

    1995-01-01

    The calculation decides the integrity of the safety latch that will hold the strong-back to the pump during lifting. The safety latch will be welded to the strong-back and will latch to a 1.5-in. dia cantilever rod welded to the pump baseplate. The static and dynamic analysis shows that the safety latch will hold the strong-back to the pump if the friction clamps fail and the pump become free from the strong-back. Thus, the safety latch will meet the requirements of the Lifting and Rigging Manual for under the hook lifting for static loading; it can withstand shock loads from the strong-back falling 0.25 inch

  9. Strong-back safety latch

    Energy Technology Data Exchange (ETDEWEB)

    DeSantis, G.N.

    1995-03-06

    The calculation decides the integrity of the safety latch that will hold the strong-back to the pump during lifting. The safety latch will be welded to the strong-back and will latch to a 1.5-in. dia cantilever rod welded to the pump baseplate. The static and dynamic analysis shows that the safety latch will hold the strong-back to the pump if the friction clamps fail and the pump become free from the strong-back. Thus, the safety latch will meet the requirements of the Lifting and Rigging Manual for under the hook lifting for static loading; it can withstand shock loads from the strong-back falling 0.25 inch.

  10. Vessel classification method based on vessel behavior in the port of Rotterdam

    NARCIS (Netherlands)

    Zhou, Y.; Daamen, W.; Vellinga, T.; Hoogendoorn, S.P.

    2015-01-01

    AIS (Automatic Identification System) data have proven to be a valuable source to investigate vessel behavior. The analysis of AIS data provides a possibility to recognize vessel behavior patterns in a waterway area. Furthermore, AIS data can be used to classify vessel behavior into several

  11. 78 FR 77430 - Proposed Information Collection; Comment Request; Foreign Fishing Vessel Permits, Vessel, and...

    Science.gov (United States)

    2013-12-23

    ... fishery or joint venture operation, transship fish harvested by a U.S. vessel to a location outside the U... fishing vessels that participate in a directed fishery or a joint venture operation. In particular these... fishing, participation in joint ventures with U.S. vessels, or transshipments of fish or fish products...

  12. Methyl green-pyronin Y staining of nucleic acids: studies on the effects of staining time, dye composition and diffusion rates

    DEFF Research Database (Denmark)

    Prentø, P; Lyon, H O

    2003-01-01

    of hypotheses have been put forward concerning kinetics and binding mechanisms. Using both filter paper models containing DNA, RNA or heparin and histological sections, we have attempted to evaluate the kinetics of staining and the role of staining time for methyl green and pyronin Y by applying the dyes...

  13. Recognition of Pneumocystis carinii by gram stain in impression smears of lung tissue.

    Science.gov (United States)

    Felegie, T P; Pasculle, A W; Dekker, A

    1984-01-01

    In 12 of 20 (60%) biopsy-proven cases of Pneumocystis carinii pneumonia, the diagnosis was first suggested by examination of routine Gram stains of impression smears made from infected lung tissue and later confirmed by methenamine-silver staining. The cysts appeared as 5- to 7-microns unstained spheres, each containing six to eight intracystic gram-negative bodies (sporozoites). Although the Gram stain does not appear to be as sensitive as more traditional staining techniques for the detection of P. carinii, clinical microbiologists should be aware of the morphology of this organism in gram-stained specimens because this relatively simple procedure gives quick results. Images PMID:6084017

  14. Clinical Utility of an Automated Instrument for Gram Staining Single Slides ▿

    Science.gov (United States)

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-01-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis. PMID:20410348

  15. Clinical utility of an automated instrument for gram staining single slides.

    Science.gov (United States)

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-06-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.

  16. A Nev Simplified Stain Extracted From The Petals of Kujarat Tea Flovers ( Hibiscus Subdariffa

    Directory of Open Access Journals (Sweden)

    Suad Z. Javadat

    2018-01-01

    The results of staining with Kujarat stain proved to be highly efficient when compared with routine stains ( such as iodine and. trichrome. In addition to that no differences vere observed between the watery and alcoholic extractsJ so the present work recommended the use of watery solution of stain ( in saline at the concentration of ( 8% wt.! vol. for both routine and teaching purposes. The dried petals can be easi1y obtained from the local markets with a cheep price and then the stain can be sasily prepared at any time.

  17. Improvements in or relating to vessels

    International Nuclear Information System (INIS)

    Williams, D.T.; Clarke, M.A.

    1977-01-01

    A reactor containment vessel is described that is suitable for a boiling water reactor, a high temperature reactor, or a liquid metal or gas cooled fast breeder reactor. Such vessels are required to contain fluids under high pressure, say in the range of 400 to 12,000 lb/sq.in. Full constructional details are given. (U.K.)

  18. Analyzing Vessel Behavior Using Process Mining

    NARCIS (Netherlands)

    Maggi, F.M.; Mooij, A.J.; Aalst, W.M.P. van der

    2013-01-01

    In the maritime domain, electronic sensors such as AIS receivers and radars collect large amounts of data about the vessels in a certain geographical area. We investigate the use of process mining techniques for analyzing the behavior of the vessels based on these data. In the context of maritime

  19. Fabrication of Separator Demonstration Facility process vessel

    International Nuclear Information System (INIS)

    Oberst, E.F.

    1985-01-01

    The process vessel system is the central element in the Separator Development Facility (SDF). It houses the two major process components, i.e., the laser-beam folding optics and the separators pods. This major subsystem is the critical-path procurement for the SDF project. Details of the vaious parts of the process vessel are given

  20. 33 CFR 401.67 - Explosive vessels.

    Science.gov (United States)

    2010-07-01

    ... TRANSPORTATION SEAWAY REGULATIONS AND RULES Regulations Dangerous Cargo § 401.67 Explosive vessels. A vessel carrying explosives, either Government or commercial, as defined in the Dangerous Cargo Act of the United States and in the International Maritime Dangerous Goods Code, Class 1, Divisions 1.1 to 1.5 inclusive...

  1. 50 CFR 300.32 - Vessel licenses.

    Science.gov (United States)

    2010-10-01

    ... Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS... Port Moresby, Papua New Guinea, who, on behalf of the license holder, will receive and respond to any... vessels of the United States engaged in joint venture arrangements, specifically: Vessels engaged in...

  2. Remission spectrometry for blood vessel detection during stereotactic biopsy of brain tumors.

    Science.gov (United States)

    Markwardt, Niklas A; Stepp, Herbert; Franz, Gerhard; Sroka, Ronald; Goetz, Marcus; Zelenkov, Petr; Rühm, Adrian

    2017-08-01

    Stereotactic biopsy is used to enable diagnostic confirmation of brain tumors and treatment planning. Despite being a well-established technique, it is related to significant morbidity and mortality rates mostly caused by hemorrhages due to blood vessel ruptures. This paper presents a method of vessel detection during stereotactic biopsy that can be easily implemented by integrating two side-view fibers into a conventional side-cutting biopsy needle. Tissue within the needle window is illuminated through the first fiber; the second fiber detects the remitted light. By taking the ratio of the intensities at two wavelengths with strongly differing hemoglobin absorption, blood vessels can be recognized immediately before biopsy sampling. Via ray tracing simulations and phantom experiments, the dependency of the remission ratio R = I 578 /I 650 on various parameters (blood oxygenation, fiber-to-vessel and inter-fiber distance, vessel diameter and orientation) was investigated for a bare-fiber probe. Up to 800-1200 µm away from the probe, a vessel can be recognized by a considerable reduction of the remission ratio from the background level. The technique was also successfully tested with a real biopsy needle probe on both optical phantoms and ex-vivo porcine brain tissue, thus showing potential to improve the safety of stereotactic biopsy. Dual-wavelength remission measurement for the detection of blood vessels during stereotactic biopsy. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Oxidized Lipoprotein as a Major Vessel Cell Proliferator in Oxidized Human Serum.

    Directory of Open Access Journals (Sweden)

    Yoshiro Saito

    Full Text Available Oxidative stress is correlated with the incidence of several diseases such as atherosclerosis and cancer, and oxidized biomolecules have been determined as biomarkers of oxidative stress; however, the detailed molecular relationship between generated oxidation products and the promotion of diseases has not been fully elucidated. In the present study, to clarify the role of serum oxidation products in vessel cell proliferation, which is related to the incidence of atherosclerosis and cancer, the major vessel cell proliferator in oxidized human serum was investigated. Oxidized human serum was prepared by free radical exposure, separated using gel chromatography, and then each fraction was added to several kinds of vessel cells including endothelial cells and smooth muscle cells. It was found that a high molecular weight fraction in oxidized human serum specifically induced vessel cell proliferation. Oxidized lipids were contained in this high molecular weight fraction, while cell proliferation activity was not observed in oxidized lipoprotein-deficient serum. Oxidized low-density lipoproteins induced vessel cell proliferation in a concentration-dependent manner. Taken together, these results indicate that oxidized lipoproteins containing lipid oxidation products function as a major vessel cell proliferator in oxidized human serum. These findings strongly indicate the relevance of determination of oxidized lipoproteins and lipid oxidation products in the diagnosis of vessel cell proliferation-related diseases such as atherosclerosis and cancer.

  4. Reliable and durable Golgi staining of brain tissue from human autopsies and experimental animals.

    Science.gov (United States)

    Rosoklija, Gorazd B; Petrushevski, Vladimir M; Stankov, Aleksandar; Dika, Ani; Jakovski, Zlatko; Pavlovski, Goran; Davcheva, Natasha; Lipkin, Richard; Schnieder, Tatiana; Scobie, Kimberley; Duma, Aleksej; Dwork, Andrew J

    2014-06-15

    Golgi stains are notoriously capricious, particularly when applied to human brain. The well-known difficulties, which include complete failure of impregnation, patchy staining, unstable staining, and extensive crystalline deposits in superficial sections, have discouraged many from attempting to use these techniques. A reliable method that produces uniform impregnation in tissue from human autopsies and experimental animals is needed. The method described, "NeoGolgi", modifies previous Golgi-Cox protocols (Glaser and Van der Loos, 1981). Changes include: much longer time (>10 weeks) in Golgi solution, agitation on a slowly rocking platform, more gradual infiltration with Parlodion, more thorough removal of excess staining solution during embedding, and shorter exposure to ammonia after infiltration. The procedure has successfully stained over 220 consecutive frontal or hippocampal blocks from more than 175 consecutive human autopsy cases. Dendritic spines are easily recognized, and background is clear, allowing examination of very thick (200 μm) sections. Stained neurons are evenly distributed within cortical regions. The stain is stable for at least eight years. Most importantly, all stained neurons are apparently well-impregnated, eliminating ambiguity between pathology and poor impregnation that is inherent to other methods. Most methods of Golgi staining are poorly predictable. They often fail completely, staining is patchy, and abnormal morphology is often indistinguishable from poor impregnation. "NeoGolgi" overcomes these problems. Starting with unfixed tissue, it is possible to obtain Golgi staining of predictably high quality in brains from human autopsies and experimental animals. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Comparison of four staining methods for detection of mast cells in equine bronchoalveolar lavage fluid.

    Science.gov (United States)

    Leclere, Mathilde; Desnoyers, Michel; Beauchamp, Guy; Lavoie, Jean-Pierre

    2006-01-01

    Mast cells normally are present in equine bronchoalveolar lavage fluid (BALF), but usually represent Romanowsky method to stain mast cell granules with that of 3 metachromatic stains: automated Romanowsky, May-Grünwald Giemsa, and toluidine blue stains. The BALF cells from 24 horses were studied. A differential cell count was performed blindly on 400 cells. The percentages of mast cells obtained were analyzed by means of repeated-measures analysis of variance and Fischer's PLSD test. The Bland and Altman method was used to assess agreement among stains. The mean percentage of mast cells in BALF was significantly lower with the fast Romanowsky than with the automated Romanowsky, May-Grünwald Giemsa, and toluidine blue stains. With the fast Romanowsky stain, the metachromatic granules of mast cells were not stained, and their identification was based on morphologic criteria. Toluidine blue staining allowed detection of the highest mean percentage of mast cells, but was inadequate for performing a differential cell count on other cell types. In conclusion, fast Romanosky stain may be inadequate for detection of mast cells in equine BALF, whereas automated Romanowsky, May-Grünwald Giemsa, and toluidine blue stains provide metachromatic staining of mast cell granules.

  6. Nuclear reactor vessel fuel thermal insulating barrier

    Energy Technology Data Exchange (ETDEWEB)

    Keegan, C. Patrick; Scobel, James H.; Wright, Richard F.

    2013-03-19

    The reactor vessel of a nuclear reactor installation which is suspended from the cold leg nozzles in a reactor cavity is provided with a lower thermal insulating barrier spaced from the reactor vessel that has a hemispherical lower section that increases in volume from the center line of the reactor to the outer extent of the diameter of the thermal insulating barrier and smoothly transitions up the side walls of the vessel. The space between the thermal insulating harrier and the reactor vessel forms a chamber which can be flooded with cooling water through passive valving to directly cool the reactor vessel in the event of a severe accident. The passive inlet valve for the cooling water includes a buoyant door that is normally maintained sealed under its own weight and floats open when the cavity is Hooded. Passively opening steam vents are also provided.

  7. Method of burying vessel containing radioactive waste

    International Nuclear Information System (INIS)

    Koga, Yoshihito.

    1989-01-01

    A float having an inert gas sealed therein is attached to a tightly closed vessel containing radioactive wastes. The vessel is inserted and kept in a small hole for burying the tightly closed vessel in an excavated shaft in rocks such as of granite or rock salts, while filling bentonite as shielding material therearound. In this case, the float is so adjusted that the apparent specific gravity is made equal or nearer between the tightly closed vessel and the bentonite, so that the rightly closed vessel does not sink and cause direct contact with the rocks even if bentonite flows due to earthquakes, etc. This can prevent radioactivity contamination through water in the rocks. (S.K.)

  8. A novel contrast stain for the rapid diagnosis of pityriasis versicolor: A comparison of Chicago Sky Blue 6B stain, potassium hydroxide mount and culture

    Directory of Open Access Journals (Sweden)

    Nikita Lodha

    2015-01-01

    Full Text Available Background: The mycological study of pityriasis versicolor is usually done by potassium hydroxide (KOH mount and culture. However, KOH mount lacks a color contrast and requires a trained eye to interpret, while culture is difficult to perform, time consuming and has low sensitivity. Chicago Sky Blue 6B (CSB is a new contrast stain that highlights the fungal hyphae and spores, blue against a purplish background. Aims and Objectives: This study was done to compare the utility of a novel contrast stain (CSB stain with KOH mount and culture. Materials and Methods: Skin scrapings from the lesions of 100 clinically diagnosed cases of P. versicolor were subjected to (1 KOH mount and CSB stain for direct microscopic examination and (2 culture using Sabouraud′s dextrose agar. The statistical analysis of CSB stain and culture was done using KOH mount as the reference method, as it is the most commonly performed and practical diagnostic test available for P. versicolor. An interrater reliability analysis using the Cohen′s Kappa statistic was performed to determine consistency (agreement among the different modalities. Observations and Results: Direct microscopy with CSB stain, KOH mount and mycological culture showed positive results in 98 (98%, 92 (92% and 56 (56% patients, respectively. Using KOH mount as the reference method, CSB stain had a sensitivity of 100% which was significantly higher than culture (60.9%. Statistically significant fair agreement was found between CSB stain and KOH mount (94% with κ=0.38, P < 0.001. Negligible agreement was found between CSB stain and culture (66%, κ=0.199, P = 0.001 as well as between KOH mount and culture (64%, κ=0.051, P = 0.107. Conclusion: CSB staining of skin scrapings is the most sensitive method for the diagnosis of pityriasis versicolor. Due to the distinct contrast provided by CSB, it is easy to perform, rapid and qualitatively superior to KOH mount.

  9. A Novel Contrast Stain for the Rapid Diagnosis of Pityriasis Versicolor: A Comparison of Chicago Sky Blue 6B Stain, Potassium Hydroxide Mount and Culture.

    Science.gov (United States)

    Lodha, Nikita; Poojary, Shital Amin

    2015-01-01

    The mycological study of pityriasis versicolor is usually done by potassium hydroxide (KOH) mount and culture. However, KOH mount lacks a color contrast and requires a trained eye to interpret, while culture is difficult to perform, time consuming and has low sensitivity. Chicago Sky Blue 6B (CSB) is a new contrast stain that highlights the fungal hyphae and spores, blue against a purplish background. This study was done to compare the utility of a novel contrast stain (CSB stain) with KOH mount and culture. Skin scrapings from the lesions of 100 clinically diagnosed cases of P. versicolor were subjected to (1) KOH mount and CSB stain for direct microscopic examination and (2) culture using Sabouraud's dextrose agar. The statistical analysis of CSB stain and culture was done using KOH mount as the reference method, as it is the most commonly performed and practical diagnostic test available for P. versicolor. An interrater reliability analysis using the Cohen's Kappa statistic was performed to determine consistency (agreement) among the different modalities. Direct microscopy with CSB stain, KOH mount and mycological culture showed positive results in 98 (98%), 92 (92%) and 56 (56%) patients, respectively. Using KOH mount as the reference method, CSB stain had a sensitivity of 100% which was significantly higher than culture (60.9%). Statistically significant fair agreement was found between CSB stain and KOH mount (94% with κ=0.38, P < 0.001). Negligible agreement was found between CSB stain and culture (66%, κ=0.199, P = 0.001) as well as between KOH mount and culture (64%, κ=0.051, P = 0.107). CSB staining of skin scrapings is the most sensitive method for the diagnosis of pityriasis versicolor. Due to the distinct contrast provided by CSB, it is easy to perform, rapid and qualitatively superior to KOH mount.

  10. Titanium: light, strong, and white

    Science.gov (United States)

    Woodruff, Laurel; Bedinger, George

    2013-01-01

    Titanium (Ti) is a strong silver-gray metal that is highly resistant to corrosion and is chemically inert. It is as strong as steel but 45 percent lighter, and it is twice as strong as aluminum but only 60 percent heavier. Titanium dioxide (TiO2) has a very high refractive index, which means that it has high light-scattering ability. As a result, TiO2 imparts whiteness, opacity, and brightness to many products. ...Because of the unique physical properties of titanium metal and the whiteness provided by TiO2, titanium is now used widely in modern industrial societies.

  11. TMA Vessel Segmentation Based on Color and Morphological Features: Application to Angiogenesis Research

    Science.gov (United States)

    Fernández-Carrobles, M. Milagro; Tadeo, Irene; Bueno, Gloria; Noguera, Rosa; Déniz, Oscar; Salido, Jesús; García-Rojo, Marcial

    2013-01-01

    Given that angiogenesis and lymphangiogenesis are strongly related to prognosis in neoplastic and other pathologies and that many methods exist that provide different results, we aim to construct a morphometric tool allowing us to measure different aspects of the shape and size of vascular vessels in a complete and accurate way. The developed tool presented is based on vessel closing which is an essential property to properly characterize the size and the shape of vascular and lymphatic vessels. The method is fast and accurate improving existing tools for angiogenesis analysis. The tool also improves the accuracy of vascular density measurements, since the set of endothelial cells forming a vessel is considered as a single object. PMID:24489494

  12. Amnioinfusion for meconium-stained liquor in labour.

    Science.gov (United States)

    Hofmeyr, G Justus; Xu, Hairong; Eke, Ahizechukwu C

    2014-01-23

    Amnioinfusion is thought to dilute meconium present in the amniotic fluid and so reduce the risk of meconium aspiration. To assess the effects of amnioinfusion for meconium-stained liquor on perinatal outcome. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (1 December 2013). Randomised trials comparing amnioinfusion with no amnioinfusion for women in labour with moderate or thick meconium staining of the amniotic fluid. Three review authors independently assessed eligibility and trial quality, and extracted data. Fourteen studies of variable quality (4435 women) are included.Subgroup analysis was performed for studies from settings with limited facilities to monitor the baby's condition during labour and intervene effectively, and settings with standard peripartum surveillance.Settings with standard peripartum surveillance: there was considerable heterogeneity for several outcomes. There was no significant reduction in the primary outcomes meconium aspiration syndrome, perinatal death or severe morbidity, and maternal death or severe morbidity. There was a reduction in caesarean sections (CSs) for fetal distress but not overall. Meconium below the vocal cords diagnosed by laryngoscopy was reduced, as was neonatal ventilation or neonatal intensive care unit admission, but there was no significant reduction in perinatal deaths or other morbidity. Planned sensitivity analysis excluding trials with greater risk of bias resulted in an absence of benefits for any of the outcomes studied.Settings with limited peripartum surveillance: three studies were included. In the amnioinfusion group there was a reduction in CS for fetal distress and overall; meconium aspiration syndrome (three studies, 1144 women; risk ratio (RR) 0.17, 95% confidence interval (CI) 0.05 to 0.52); perinatal mortality (three studies, 1151 women; RR 0.24, 95% CI 0.11 to 0.53) and neonatal ventilation or neonatal intensive care unit admission. In one of the studies, meconium

  13. Quantitative three-dimensional evaluation of immunofluorescence staining for large whole mount spheroids with light sheet microscopy.

    Science.gov (United States)

    Smyrek, I; Stelzer, E H K

    2017-02-01

    Three-dimensional cell biology and histology of tissue sections strongly benefit from advanced light microscopy and optimized staining procedures to gather the full three-dimensional information. In particular, the combination of optical clearing with light sheet-based fluorescence microscopy simplifies fast high-quality imaging of thick biological specimens. However, verified in toto immunostaining protocols for large multicellular spheroids or for tissue sections have not been published. We present a method for the verification of immunostaining in three-dimensional spheroids. The analysis relies on three criteria to evaluate the immunostaining quality: quality of the antibody stain specificity, signal intensity achieved by the staining procedure and the correlation of the signal intensity with that of a homogeneously dispersed fluorescent dye. We optimized and investigated variations of five immunostaining protocols for three-dimensional cell biology. Our method is an important contribution to three-dimensional cell biology and the histology of tissues since it allows to evaluate the efficiency of immunostaining protocols for large three-dimensional specimens, and to study the distribution of protein expression and cell types within spheroids and spheroid-specific morphological structures without the need of physical sectioning.

  14. Facile and eco-friendly synthesis of green fluorescent carbon nanodots for applications in bioimaging, patterning and staining.

    Science.gov (United States)

    Shi, Lihong; Li, Yanyan; Li, Xiaofeng; Wen, Xiangping; Zhang, Guomei; Yang, Jun; Dong, Chuan; Shuang, Shaomin

    2015-04-28

    We report a facile and eco-friendly strategy for the fabrication of green fluorescent carbon nanodots (CDs), and demonstrate their applications for bio-imaging, patterning, and staining. A one-pot hydrothermal method using various plant petals yields bright green-emitting CDs, providing an easy way for the production of green fluorescent CDs without the need for a tedious synthetic methodology or the use of toxic/expensive solvents and starting materials. The as-prepared CDs show small size distribution and excellent dispersibility. Their strong green fluorescence is observed when the excitation wavelength is between 430 nm and 490 nm. Moreover, they exhibit high tolerance to various external conditions, such as pH values, external cations, and continuous excitation. Due to minimum toxicity as well as good photoluminescence properties, these CDs can be applied to in vitro and in vivo imaging, patterning, and staining. According to confocal fluorescence imaging of human uterine cervical squamous cell carcinoma cells, CDs penetrate into the cell and enter the cytoplasm and the nucleus. More strikingly, carp is directly fed with CDs for in vivo imaging and shows bright green fluorescence at an excitation wavelength of 470 nm. In addition, the obtained CDs are used as fluorescent inks for drawing luminescence patterns. Finally, we also apply the CDs as a fluorescent dye. Interestingly, the absorbent filter paper with staining emits dramatic fluorescence under 470 nm excitation.

  15. Lightweight bladder lined pressure vessels

    Science.gov (United States)

    Mitlitsky, Fred; Myers, Blake; Magnotta, Frank

    1998-01-01

    A lightweight, low permeability liner for graphite epoxy composite compressed gas storage vessels. The liner is composed of polymers that may or may not be coated with a thin layer of a low permeability material, such as silver, gold, or aluminum, deposited on a thin polymeric layer or substrate which is formed into a closed bladder using torispherical or near torispherical end caps, with or without bosses therein, about which a high strength to weight material, such as graphite epoxy composite shell, is formed to withstand the storage pressure forces. The polymeric substrate may be laminated on one or both sides with additional layers of polymeric film. The liner may be formed to a desired configuration using a dissolvable mandrel or by inflation techniques and the edges of the film seamed by heat sealing. The liner may be utilized in most any type of gas storage system, and is particularly applicable for hydrogen, gas mixtures, and oxygen used for vehicles, fuel cells or regenerative fuel cell applications, high altitude solar powered aircraft, hybrid energy storage/propulsion systems, and lunar/Mars space applications, and other applications requiring high cycle life.

  16. Comparison of staining of mitotic figures by haematoxylin and eosin-and crystal violet stains, in oral epithelial dysplasia and squamous cell carcinoma

    Directory of Open Access Journals (Sweden)

    Ankle Madhuri

    2007-01-01

    Full Text Available Mitosis of cells gives rise to tissue integrity. Defects during mitosis bring about abnormalities. Excessive proliferation of cells due to increased mitosis is one such outcome, which is the hallmark in precancer and cancer. The localization of proliferating cells or their precursors may not be obvious and easy. Establishing an easy way to distinguish these mitotic cells will help in grading and understanding their biological potential. Although immunohistochemistry is an advanced method in use, the cost and time factor makes it less feasible for many laboratories. Selective histochemical stains like toluidine blue, giemsa and crystal violet have been used in tissues including the developing brain, neural tissue and skin. Aim of the study: 1To compare the staining of mitotic cells in haematoxylin and eosin with that in crystal violet. 2To compare the number of mitotic figures present in normal oral mucosa, epithelial dysplasia and oral squamous cell carcinoma in crystal violet-stained sections with that in H and E-stained sections. Materials and Methods: Ten tissues of normal oral mucosa and 15 tissues each of oral epithelial dysplasia seen in tobacco-associated leukoplakia and squamous cell carcinoma were studied to evaluate the selectivity of 1% crystal violet for mitotic figures. The staining was compared with standard H and E staining. Statistical analysis was done using Man-Whitney U test. Results: A statistically significant increase in the mean mitotic count was observed in crystal violet-stained sections of epithelial dysplasia as compared to the H and E-stained sections ( p = 0.0327. A similar increase in the mitotic counts was noted in crystal violet-stained sections of oral squamous cell carcinoma as compared to the H and E-stained sections.( p = 0.0443. No significant difference was found in the mitotic counts determined in dysplasia or carcinoma by either the crystal violet ( p = 0.4429 or the H and E-staining techniques ( p = 0

  17. Nitric oxide dilates rat retinal blood vessels by cyclooxygenase-dependent mechanisms.

    Science.gov (United States)

    Ogawa, Naoto; Mori, Asami; Hasebe, Masami; Hoshino, Maya; Saito, Maki; Sakamoto, Kenji; Nakahara, Tsutomu; Ishii, Kunio

    2009-10-01

    It has been suggested that nitric oxide (NO) stimulates the cyclooxygenase (COX)-dependent mechanisms in the ocular vasculature; however, the importance of the pathway in regulating retinal circulation in vivo remains to be elucidated. Therefore, we investigated the role of COX-dependent mechanisms in NO-induced vasodilation of retinal blood vessels in thiobutabarbital-anesthetized rats with and without neuronal blockade (tetrodotoxin treatment). Fundus images were captured with a digital camera that was equipped with a special objective lens. The retinal vascular response was assessed by measuring changes in diameter of the retinal blood vessel. The localization of COX and soluble guanylyl cyclase in rat retina was examined using immunohistochemistry. The NO donors (sodium nitroprusside and NOR3) increased the diameter of the retinal blood vessels but decreased systemic blood pressure in a dose-dependent manner. Treatment of rats with indomethacin, a nonselective COX inhibitor, or SC-560, a selective COX-1 inhibitor, markedly attenuated the vasodilation of retinal arterioles, but not the depressor response, to the NO donors. However, both the vascular responses to NO donors were unaffected by the selective COX-2 inhibitors NS-398 and nimesulide. Indomethacin did not change the retinal vascular and depressor responses to hydralazine, 8-(4-chlorophenylthio)-guanosine-3', 5'-cyclic monophosphate (a membrane-permeable cGMP analog) and 8-(4-chlorophenylthio)-adenosine-3', 5'-cyclic monophosphate (a membrane-permeable cAMP analog). Treatment with SQ 22536, an adenylyl cyclase inhibitor, but not ODQ, a soluble guanylyl cyclase inhibitor, significantly attenuated the NOR3-induced vasodilation of retinal arterioles. The COX-1 immunoreactivity was found in retinal blood vessels. The retinal blood vessel was faintly stained for soluble guanylyl cyclase, although the apparent immunoreactivities on mesenteric and choroidal blood vessels were observed. These results suggest

  18. ITER vacuum vessel structural analysis completion during manufacturing phase

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, J.-M., E-mail: jean-marc.martinez@live.fr [ITER Organization, Route Vinon sur Verdon, CS 90046, 13067, St. Paul lez Durance, Cedex (France); Alekseev, A.; Sborchia, C.; Choi, C.H.; Utin, Y.; Jun, C.H.; Terasawa, A.; Popova, E.; Xiang, B.; Sannazaro, G.; Lee, A.; Martin, A.; Teissier, P.; Sabourin, F. [ITER Organization, Route Vinon sur Verdon, CS 90046, 13067, St. Paul lez Durance, Cedex (France); Caixas, J.; Fernandez, E.; Zarzalejos, J.M. [F4E, c/Josep Pla, n.2, Torres Diagonal Litoral, Edificio B3, E-08019, Barcelona (Spain); Kim, H.-S.; Kim, Y.G. [ITER Korea, National Fusion Research Institute, Daejeon (Korea, Republic of); Privalova, E. [NTC “Sintez”, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); and others

    2016-11-01

    Highlights: • ITER Vacuum Vessel (VV) is a part of the first barrier to confine the plasma. • A Nuclear Pressure Equipment necessitates Agreed Notified Body to assure design, fabrication, and conformance testing and quality assurance. • Some supplementary RCC-MR margin targets have been considered to guarantee considerable structural margins in areas not inspected in operation. • Many manufacturing deviation requests (MDR) and project change requests (PCR) impose to re-evaluate the structural margin. • Several structural analyses were performed with global and local models to guarantee the structural integrity of the whole ITER Vacuum Vessel. - Abstract: Some years ago, analyses were performed by ITER Organization Central Team (IO-CT) to verify the structural integrity of the ITER vacuum vessel baseline design fixed in 2010 and classified as a Protection Important Component (PIC). The manufacturing phase leads the ITER Organization domestic agencies (IO-DA) and their contracted manufacturers to propose detailed design improvements to optimize the manufacturing or inspection process. These design and quality inspection changes can affect the structural margins with regards to the Codes&Standards and thus oblige to evaluate one more time the modified areas. This paper proposes an overview of the additional analyses already performed to guarantee the structural integrity of the manufacturing designs. In this way, CT and DAs have been strongly involved to keep the considerable margins obtained previously which were used to fix reasonable compensatory measures for the lack of In Service Inspections of a Nuclear Pressure Equipment (NPE).

  19. Lymph Node Metastases in Papillary and Medullary Thyroid Carcinoma Are Independent of Intratumoral Lymphatic Vessel Density

    Science.gov (United States)

    Pereira, Filipe; Pereira, Sofia S.; Mesquita, Marta; Morais, Tiago; Costa, Madalena M.; Quelhas, Pedro; Lopes, Carlos; Monteiro, Mariana P.; Leite, Valeriano

    2017-01-01

    Background Blood and lymph vessel invasion are well-recognized markers of tumor aggressiveness, as these are the routes that lead to metastases. Thyroid tumors, depending on the histological variant, tend to have distinctive biological behaviors and use different vascular routes to metastasize, yet the mechanisms underlying the metastatic process are still poorly understood. Objectives The aim of this study was to assess how the lymph vessel density (LVD) in different histological types of thyroid tumors, and in their surrounding tissue, correlate with the presence of lymph node metastases (LNM) and tumor pathological features. Methods Lymph vessels of papillary thyroid carcinomas (PTC), of the classical (CVPTC, n = 50) and follicular variants (FVPTC, n = 18), and medullary thyroid carcinomas (MTC, n = 34) were immunohistochemically stained against antigen D2-40. The stained area was quantified using a computerized morphometric analysis tool and correlated with the tumor pathological characteristics. Results LVD within all analyzed thyroid tumor subtypes was significantly lower than in the surrounding thyroid tissues (p < 0.001). Despite intratumoral LVD being significantly higher in CVPTC than in FVPTC, and peritumoral LVD being significantly higher in MTC than in PTC (p < 0.05), no correlations were found between LVD (either intratumoral or peritumoral) and the presence of lymph node metastasis. Conclusions As no LVD differences were found amongst thyroid tumors with or without LNM, dissemination is more likely to depend on the tumor ability to invade the abundant lymph vessel network of the surrounding thyroid tissue than on the ability of the tumor to promote de novo lymphangiogenesis. PMID:28589086

  20. Integrity of the reactor vessel support system for a postulated reactor vessel closure head drop event

    International Nuclear Information System (INIS)

    Kim, Tae Wan; Lee, Ki Young; Lee, Dae Hee; Kim, Kang Soo

    1996-01-01

    The integrity of reactor vessel support system of the Korean Standard Nuclear Power Plant (KSNPP) is investigated for a postulated reactor vessel closure head drop event. The closure head is disassembled from the reactor vessel during refueling process or general inspection of reactor vessel and internal structures, and carried to proposed location by the head lift rig. A postulated closure head drop event could be anticipated during closure head handling process. The drop event may cause an impact load on the reactor vessel and supporting system. The integrity of the supporting system is directly relevant to that of reactor vessel and reactor internals including fuels. Results derived by elastic impact analysis, linear and non-linear buckling analysis and elasto-plastic stress analysis of the supporting system implied that the integrity of the reactor vessel supporting system is intact for a postulated reactor closure head drop event. 9 refs., 10 figs., 3 tabs. (author)

  1. AN EFFICIENT TECHNIQUE FOR RETINAL VESSEL SEGMENTATION AND DENOISING USING MODIFIED ISODATA AND CLAHE

    Directory of Open Access Journals (Sweden)

    Khan Bahadar Khan

    2016-11-01

    Full Text Available Retinal damage caused due to complications of diabetes is known as Diabetic Retinopathy (DR. In this case, the vision is obscured due to the damage of retinal tinny blood vessels of the retina. These tinny blood vessels may cause leakage which affect the vision and can lead to complete blindness. Identification of these new retinal vessels and their structure is essential for analysis of DR. Automatic blood vessels segmentation plays a significant role to assist subsequent automatic methodologies that aid to such analysis. In literature most of the people have used computationally hungry a strong preprocessing steps followed by a simple thresholding and post processing, But in our proposed technique we utilize an arrangement of  light pre-processing which consists of Contrast Limited Adaptive Histogram Equalization (CLAHE for contrast enhancement, a difference image of green channel from its Gaussian blur filtered image to remove local noise or geometrical object, Modified Iterative Self Organizing Data Analysis Technique (MISODATA for segmentation of vessel and non-vessel pixels based on global and local thresholding, and a strong  post processing using region properties (area, eccentricity to eliminate the unwanted region/segment, non-vessel pixels and noise that never been used to reject misclassified foreground pixels. The strategy is tested on the publically accessible DRIVE (Digital Retinal Images for Vessel Extraction and STARE (STructured Analysis of the REtina databases. The performance of proposed technique is assessed comprehensively and the acquired accuracy, robustness, low complexity and high efficiency and very less computational time that make the method an efficient tool for automatic retinal image analysis. Proposed technique perform well as compared to the existing strategies on the online available databases in term of accuracy, sensitivity, specificity, false positive rate, true positive rate and area under receiver

  2. Presence of intratumoral platelets is associated with tumor vessel structure and metastasis

    International Nuclear Information System (INIS)

    Li, Rong; Zhang, Xu; Zhang, Zhuo; Zhang, Xiao; Ran, Bing; Wu, Jianbo; Ren, Meiping; Chen, Ni; Luo, Mao; Deng, Xin; Xia, Jiyi; Yu, Guang; Liu, Jinbo; He, Bing

    2014-01-01

    Platelets play a fundamental role in maintaining hemostasis and have been shown to participate in hematogenous dissemination of tumor cells. Abundant platelets were detected in the tumor microenvironment outside of the blood vessel, thus, platelet -tumor cell interaction outside of the bloodstream may play a role in regulating primary tumor growth and metastasis initiation. However, it is unclear that platelet depletion affects tumor vessel structure and dynamics. Using thrombocytopenia induction in two different tumor-bearing mouse models, tumor tissues were performed by Westernblotting and immunohistochemical staining. Vascular permeability was evaluated by determination of intratumoral Evans blue and Miles vascular permeability assay. Furthermore, microdialysis was used to examining the intratumoral extracellular angiogenic growth factors (VEGF, TGF-β) by ELISA. Platelet depletion showed no change in tumor growth and reduced lung metastasis. Platelet depletion led to reduced tumor hypoxia and Met receptor activation and was associated with a decreased release of MMP-2, 9, PAI-1, VEGF, and TGF-β. Tumor vessels in platelet-depleted mice showed impaired vessel density and maturation. Our findings demonstrate that platelets within the primary tumor microenvironment play a critical role in the induction of vascular permeability and initiation of tumor metastasis

  3. Coffee-stain growth dynamics on dry and wet surfaces

    Science.gov (United States)

    Boulogne, François; Ingremeau, François; Stone, Howard A.

    2017-02-01

    The drying of a drop containing particles often results in the accumulation of the particles at the contact line. In this work, we investigate the drying of an aqueous colloidal drop surrounded by a hydrogel that is also evaporating. We combine theoretical and experimental studies to understand how the surrounding vapor concentration affects the particle deposit during the constant radius evaporation mode. In addition to the common case of evaporation on an otherwise dry surface, we show that in a configuration where liquid is evaporating from a flat surface around the drop, the singularity of the evaporative flux at the contact line is suppressed and the drop evaporation is homogeneous. For both conditions, we derive the velocity field and we establish the temporal evolution of the number of particles accumulated at the contact line. We predict the growth dynamics of the stain and the drying timescales. Thus, dry and wet conditions are compared with experimental results and we highlight that only the dynamics is modified by the evaporation conditions, not the final accumulation at the contact line.

  4. Effect of staining solutions on discoloration of resin nanocomposites.

    Science.gov (United States)

    Park, Jeong-Kil; Kim, Tae-Hyong; Ko, Ching-Chang; García-Godoy, Franklin; Kim, Hyung-Il; Kwon, Yong Hoon

    2010-02-01

    To examine the effect of staining solutions on the discoloration of resin nanocomposites. Three resin nanocomposites (Ceram X, Grandio, and Filtek Z350) were light cured for 40 seconds at a light intensity of 1000 mW/cm2. The color of the specimens was measured in %R (reflectance) mode before and after immersing the specimens in four different test solutions [distilled water (DW), coffee (CF), 50% ethanol (50ET) and brewed green tea (GT)] for 7 hours/day over a 3-week period. The color difference (deltaE*) was obtained based on the CIEL*a*b* color coordinate values. The specimens immersed in DW, 50ET and GT showed a slight increase in L* value. However, the samples immersed in CF showed a decrease in the L* value and an increase in the b* value. CF induced a significant color change (deltaE*: 3.1-5.6) in most specimens but the other solutions induced only a slight color change. Overall, coffee caused unacceptable color changes to the resin nanocomposites.

  5. Development of a stained cell nuclei counting system

    Science.gov (United States)

    Timilsina, Niranjan; Moffatt, Christopher; Okada, Kazunori

    2011-03-01

    This paper presents a novel cell counting system which exploits the Fast Radial Symmetry Transformation (FRST) algorithm [1]. The driving force behind our system is a research on neurogenesis in the intact nervous system of Manduca Sexta or the Tobacco Hornworm, which was being studied to assess the impact of age, food and environment on neurogenesis. The varying thickness of the intact nervous system in this species often yields images with inhomogeneous background and inconsistencies such as varying illumination, variable contrast, and irregular cell size. For automated counting, such inhomogeneity and inconsistencies must be addressed, which no existing work has done successfully. Thus, our goal is to devise a new cell counting algorithm for the images with non-uniform background. Our solution adapts FRST: a computer vision algorithm which is designed to detect points of interest on circular regions such as human eyes. This algorithm enhances the occurrences of the stained-cell nuclei in 2D digital images and negates the problems caused by their inhomogeneity. Besides FRST, our algorithm employs standard image processing methods, such as mathematical morphology and connected component analysis. We have evaluated the developed cell counting system with fourteen digital images of Tobacco Hornworm's nervous system collected for this study with ground-truth cell counts by biology experts. Experimental results show that our system has a minimum error of 1.41% and mean error of 16.68% which is at least forty-four percent better than the algorithm without FRST.

  6. Zebrafish embryology and cartilage staining protocols for high school students.

    Science.gov (United States)

    Emran, Farida; Brooks, Jacqueline M; Zimmerman, Steven R; Johnson, Susan L; Lue, Robert A

    2009-06-01

    The Life Sciences-Howard Hughes Medical Institute Outreach Program at Harvard University supports high school science education by offering an on-campus program for students and their teachers to participate in investigative, hands-on laboratory sessions. The outreach program has recently designed and launched a successful zebrafish embryology protocol that we present here. The main objectives of this protocol are to introduce students to zebrafish as a model research organism and to provide students with direct experience with current techniques used in embryological research. The content of the lab is designed to generate discussions on embryology, genetics, fertilization, natural selection, and animal adaptation. The protocol produces reliable results in a time-efficient manner using a minimum of reagents. The protocol presented here consists of three sections: observations of live zebrafish larvae at different developmental stages, cartilage staining of zebrafish larvae, and a mutant hunt involving identification of two zebrafish mutants (nacre and chokh). Here, we describe the protocol, show the results obtained for each section, and suggest possible alternatives for different lab settings.

  7. Akreditasi Perpustakaan Perguruan Tinggi: Pengalaman Perpustakaan STAIN Kediri

    Directory of Open Access Journals (Sweden)

    Komarudin Komarudin

    2016-07-01

    Abstract; The importance of quality has been a concern of college library librarian. National Library has compiled standards can be used as a minimum level college library quality. A form of formal recognition of compliance with these standards is by accrediting library. Accreditation aims to improve accredited institution so useful to build a library quality. As stipulated by Law Decree(UU No. 43 of 2007 and Government Regulation (PPNo. 24 of 2014, the National Library has the National Library Accreditation Agency (LAP-N. Accredited certificate can obtain a library based on the number of components weighted values of service, cooperation, collection, organization of library materials, human resources, building / space and infrastructure, budget, library management and maintenance of library collection. The experience of STAIN Kediri library in carrying out the library accreditation including : make a plan of accreditation activities, form preparation team of accreditation, perform self assessments, set up support files, send a letter of application and data file support, assessment accreditation forms, prepare for site assessment and carry out the acreditation. The main thing is the accreditation is a culture of quality. Hope to obtain the best value of accreditation lies in the culture of quality.

  8. 78 FR 40891 - Revisions to the Export Administration Regulations: Military Vehicles; Vessels of War...

    Science.gov (United States)

    2013-07-08

    ... Vehicles; Vessels of War; Submersible Vessels, Oceanographic Equipment; Related Items; and Auxiliary and... Regulations: Military Vehicles; Vessels of War; Submersible Vessels, Oceanographic Equipment; Related Items... military vehicles and related items; vessels of war and related items; submersible vessels, oceanographic...

  9. Correlation between expressions of hypoxia -inducible factor (HIF-1α, blood vessels density, cell proliferation, and apoptosis intensity in canine fibromas and fibrosarcomas

    Directory of Open Access Journals (Sweden)

    Madej Janusz A.

    2014-03-01

    Full Text Available The study aimed to demonstrate the expression of hypoxia-inducible factor (HIF-1α in soft tissue mesenchymal tumours (fibroma and fibrosarcoma in dogs. An attempt was made to correlate the obtained results with density of blood vessels (expression of von Willebrand Factor, vWF, expression of Ki-67 proliferation antigen, and with intensity of apoptosis in studied tumours. The study was performed on paraffin sections of 15 fibromas and 40 fibrosarcomas sampled from 55 female dogs aged 6 to 16 years. Immunohistochemical staining against HIF-1α, vWF, and Ki-67 was performed. Apoptosis was detected with the use of TUNEL reaction. A significantly higher HIF-1α expression was noted in fibrosarcomas in comparison to fibromas (P < 0.0001. HIF-1α expression in fibromas manifested strong positive correlation with tumour vascularity (r = 0.67, P = 0.007. Moreover, HIF-1α expression in fibrosarcomas manifested a moderate positive correlation with tumour malignancy grade (r = 0.44, P = 0.004, tumour vascularity (r = 0.52, P < 0.001, Ki-67 antigen expression (r = 0.42; P = 0.007, and TUNELpositive cells (r = 0.37, P = 0.017. Expression of HIF-1α was detected in 86.7% of fibroma type tumours and in 100% of fibrosarcomas. In all studied tumours expression of HIF-1α manifested positive correlation with the density of blood vessels, and in fibrosarcomas it correlated also with malignancy grade, intensity of Ki-67 expression, and with intensity of apoptosis in tumour cells.

  10. Design of the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.

    1995-01-01

    The ITER vacuum vessel is a major safety barrier and must support electromagnetic loads during plasma disruptions and vertical displacement events (VDE) and withstand plausible accidents without losing confinement.The vacuum vessel has a double wall structure to provide structural and electrical continuity in the toroidal direction. The inner and outer shells and poloidal stiffening ribs between them are joined by welding, which gives the vessel the required mechanical strength. The space between the shells will be filled with steel balls and plate inserts to provide additional nuclear shielding. Water flowing in this space is required to remove nuclear heat deposition, which is 0.2-2.5% of the total fusion power. The minor and major radii of the tokamak are 3.9 m and 13 m respectively, and the overall height is 15 m. The total thickness of the vessel wall structure is 0.4-0.7 m.The inboard and outboard blanket segments are supported from the vacuum vessel. The support structure is required to withstand a large total vertical force of 200-300 MN due to VDE and to allow for differential thermal expansion.The first candidate for the vacuum vessel material is Inconel 625, due to its higher electric resistivity and higher yield strength, even at high temperatures. Type 316 stainless steel is also considered a vacuum vessel material candidate, owing to its large database and because it is supported by more conventional fabrication technology. (orig.)

  11. Composite Overwrapped Pressure Vessels, A Primer

    Science.gov (United States)

    McLaughlan, Pat B.; Forth, Scott C.; Grimes-Ledesma, Lorie R.

    2011-01-01

    Due to the extensive amount of detailed information that has been published on composite overwrapped pressure vessels (COPVs), this document has been written to serve as a primer for those who desire an elementary knowledge of COPVs and the factors affecting composite safety. In this application, the word "composite" simply refers to a matrix of continuous fibers contained within a resin and wrapped over a pressure barrier to form a vessel for gas or liquid containment. COPVs are currently used at NASA to contain high pressure fluids in propulsion, science experiments, and life support applications. They have a significant weight advantage over all metal vessels but require unique design, manufacturing, and test requirements. COPVs also involve a much more complex mechanical understanding due to the interplay between the composite overwrap and the inner liner. A metallic liner is typically used in a COPV as a fluid permeation barrier. The liner design concepts and requirements have been borrowed from all-metal vessels. However, application of metallic vessel design standards to a very thin liner is not straightforward. Different failure modes exist for COPVs than for all-metal vessels, and understanding of these failure modes is at a much more rudimentary level than for metal vessels.

  12. Recent Advancements in Retinal Vessel Segmentation.

    Science.gov (United States)

    L Srinidhi, Chetan; Aparna, P; Rajan, Jeny

    2017-04-01

    Retinal vessel segmentation is a key step towards the accurate visualization, diagnosis, early treatment and surgery planning of ocular diseases. For the last two decades, a tremendous amount of research has been dedicated in developing automated methods for segmentation of blood vessels from retinal fundus images. Despite the fact, segmentation of retinal vessels still remains a challenging task due to the presence of abnormalities, varying size and shape of the vessels, non-uniform illumination and anatomical variability between subjects. In this paper, we carry out a systematic review of the most recent advancements in retinal vessel segmentation methods published in last five years. The objectives of this study are as follows: first, we discuss the most crucial preprocessing steps that are involved in accurate segmentation of vessels. Second, we review most recent state-of-the-art retinal vessel segmentation techniques which are classified into different categories based on their main principle. Third, we quantitatively analyse these methods in terms of its sensitivity, specificity, accuracy, area under the curve and discuss newly introduced performance metrics in current literature. Fourth, we discuss the advantages and limitations of the existing segmentation techniques. Finally, we provide an insight into active problems and possible future directions towards building successful computer-aided diagnostic system.

  13. Blood culture gram stain, acridine orange stain and direct sensitivity-based antimicrobial therapy of bloodstream infection in patients with trauma.

    Science.gov (United States)

    Behera, B; Mathur, P; Gupta, B

    2010-01-01

    The purpose of this study was to ascertain if the simple practice of Gram stain, acridine orange stain and direct sensitivity determination of positive blood culture bottles could be used to guide early and appropriate treatment in trauma patients with clinical suspicion of sepsis. The study also aimed to evaluate the error in interpreting antimicrobial sensitivity by direct method when compared to standard method and find out if specific antibiotic-organism combination had more discrepancies. Findings from consecutive episodes of blood stream infection at an Apex Trauma centre over a 12-month period are summarized. A total of 509 consecutive positive blood cultures were subjected to Gram staining. AO staining was done in BacT/ALERT-positive Gram-stain negative blood cultures. Direct sensitivity was performed from 369 blood culture broths, showing single type of growth in Gram and acridine orange staining. Results of direct sensitivity were compared to conventional sensitivity for errors. No 'very major' discrepancy was found in this study. About 5.2 and 1.8% minor error rates were noted in gram-positive and gram-negative bacteria, respectively, while comparing the two methods. Most of the discrepancies in gram-negative bacteria were noted in beta lactam - beta lactamase inhibitor combinations. Direct sensitivity testing was not reliable for reporting of methicillin and vancomycin resistance in Staphylococci. Gram stain result together with direct sensitivity testing is required for optimizing initial antimicrobial therapy in trauma patients with clinical suspicion of sepsis. Gram staining and AO staining proved particularly helpful in the early detection of candidaemia.

  14. How Romanowsky stains work and why they remain valuable - including a proposed universal Romanowsky staining mechanism and a rational troubleshooting scheme.

    Science.gov (United States)

    Horobin, R W

    2011-02-01

    An introduction to the nomenclature and concept of "Romanowsky stains" is followed by a brief account of the dyes involved and especially the crucial role of azure B and of the impurity of most commercial dye lots. Technical features of standardized and traditional Romanowsky stains are outlined, e.g., number and ratio of the acidic and basic dyes used, solvent effects, staining times, and fixation effects. The peculiar advantages of Romanowsky staining are noted, namely, the polychromasia achieved in a technically simple manner with the potential for stain intensification of "the color purple." Accounts are provided of a variety of physicochemically relevant topics, namely, acidic and basic dyeing, peculiarities of acidic and basic dye mixtures, consequences of differential staining rates of different cell and tissue components and of different dyes, the chemical significance of "the color purple," the substrate selectivity for purple color formation and its intensification in situ due to a template effect, effects of resin embedding and prior fixation. Based on these physicochemical phenomena, mechanisms for the various Romanowsky staining applications are outlined including for blood, marrow and cytological smears; G-bands of chromosomes; microorganisms and other single-cell entities; and paraffin and resin tissue sections. The common factors involved in these specific mechanisms are pulled together to generate a "universal" generic mechanism for these stains. Certain generic problems of Romanowsky stains are discussed including the instability of solutions of acidic dye-basic dye mixtures, the inherent heterogeneity of polychrome methylene blue, and the resulting problems of standardization. Finally, a rational trouble-shooting scheme is appended.

  15. Is the gram stain useful in the microbiologic diagnosis of VAP? A meta-analysis.

    Science.gov (United States)

    O'Horo, John C; Thompson, Deb; Safdar, Nasia

    2012-08-01

    In a meta-analysis examining respiratory specimen Gram stain for diagnosis of ventilator-associated pneumonia, absence of bacteria on Gram stain had a high negative predictive value, but a positive Gram stain correlated poorly with organisms recovered in culture. Rapid and accurate diagnosis of ventilator-associated pneumonia (VAP) is a major challenge and no generally accepted gold standard exists for VAP diagnosis. We conducted a meta-analysis to examine the role of respiratory specimen Gram stain to diagnose VAP, and the correlation with final culture results. In 21 studies, pooled sensitivity of Gram stain for VAP was 0.79 (95% confidence interval [CI], .77-0.81; P Gram stain for a VAP prevalence of 20%-30% was 91%, suggesting that VAP is unlikely with a negative Gram stain but the positive predictive value of Gram stain was only 40%. Pooled kappa was 0.42 for gram-positive organisms and 0.34 for gram-negative organisms, suggesting fair concordance between organisms on Gram stain and recovery by culture. Therefore, a positive Gram stain should not be used to narrow anti-infective therapy until culture results become available.

  16. Hyperspectral imaging of the crime scene for detection and identification of blood stains

    Science.gov (United States)

    Edelman, G. J.; van Leeuwen, T. G.; Aalders, M. C. G.

    2013-05-01

    Blood stains are an important source of information in forensic investigations. Extraction of DNA may lead to the identification of victims or suspects, while the blood stain pattern may reveal useful information for the reconstruction of a crime. Consequently, techniques for the detection and identification of blood stains are ideally non-destructive in order not to hamper both DNA and the blood stain pattern analysis. Currently, forensic investigators mainly detect and identify blood stains using chemical or optical methods, which are often either destructive or subject to human interpretation. We demonstrated the feasibility of hyperspectral imaging of the crime scene to detect and identify blood stains remotely. Blood stains outside the human body comprise the main chromophores oxy-hemoglobin, methemoglobin and hemichrome. Consequently, the reflectance spectra of blood stains are influenced by the composite of the optical properties of the individual chromophores and the substrate. Using the coefficient of determination between a non-linear least squares multi-component fit and the measured spectra blood stains were successfully distinguished from other substances visually resembling blood (e.g. ketchup, red wine and lip stick) with a sensitivity of 100 % and a specificity of 85 %. The practical applicability of this technique was demonstrated at a mock crime scene, where blood stains were successfully identified automatically.

  17. Leishman-Giemsa cocktail: an effective Romanowsky stain for air-dried cytologic smears.

    Science.gov (United States)

    Garbyal, Rajendra S; Agarwal, Neeta; Kumar, Prachi

    2006-01-01

    To develop an economical, quick, readily available and simple alternative to May-Grünwald-Giemsa (MGG) stain and so to explore the combination of Leishman and Giemsa stain (LG cocktail). One wet-fixed and 2 air-dried smears were prepared from 720 cases during the period January 2003-November 2004. The LG cocktail and MGG stain were used on the air-dried smears and Papanicolaou stain in wet-fixed smears. Diagnoses of the cases were made using the LG cocktail-stained smears, and then its diagnostic efficacy was cross-checked with the MGG- and Papanicolaou-stained smears by the same cytopathologist. A comparative study of the LG cocktail and MGG-stained smears was done. The results achieved with the LG cocktail-stained smears were comparable to or even better than those with the MGG-stained smears, with excellent diagnostic efficacy. As compared to MGG stain, the 1-step LG cocktail is cheaper, easier to standardize and quicker.

  18. A simple and sensitive method for the activity staining of xanthine oxidase.

    Science.gov (United States)

    Ozer, N; Muftüoglu, M; Hamdi Ogus, I

    1998-06-11

    Xanthine oxidase is a commercially-important enzyme. Several biochemical compounds have been quantitated by xanthine oxidase. Xanthine oxidase has been used as an auxiliary enzyme in the staining of several enzymes or tissues, however, there is no direct staining method available for it, on polyacrylamide gels. Partially-purified xanthine oxidase from cow milk was used as the enzyme source for the development of an activity-staining method on polyacrylamide gels. Staining was very sensitive. Detection of 0.02 microU of the enzyme on polyacrylamide gels was possible. Staining of 0.05 microU takes about 1 min whereas staining of 0.5 microU will take less than 5 s. Addition of TEMED is not essential for activity staining but it did increase both the rate and the intensity of the staining. The stained gels must be washed with distilled water, extensively, in order to remove excess unoxidized nitroblue tetrazolium, and must be protected from light, for a clear background and sharp activity-band staining. This method might be useful for quality control of xanthine oxidase obtained from different sources.

  19. A confocal scanning laser ophthalmoscope for retinal vessel oximetry

    Science.gov (United States)

    Lompado, Arthur

    Measurement of a person's blood oxygen saturation has long been recognized as a useful metric for the characterizing ailments ranging from chronic respiratory disorders to acute, potentially life threatening, traumas. The ubiquity of oxygen saturation monitors in the medical field, including portable pulse oximeters and laboratory based CO-oximeters, is a testament to the importance of this technique. The work presented here documents the design, fabrication and development of a unique type of oxygen saturation monitor, a confocal scanning retinal vessel oximeter, with the potential to expand the usefulness of the present devices. A large part of the knowledge base required to construct the instrument comes from the consideration of light scattering by red blood cells in a blood vessel. Therefore, a substantial portion of this work is devoted to the process of light scattering by whole human blood and its effects on the development of a more accurate oximeter. This light scattering effect has been both measured and modeled stochastically to determine its contribution to the measured oximeter signal. It is shown that, although well accepted in the published literature, the model only correlates marginally to the measurements due to inherent limitations imposed by the model assumptions. Nonetheless, enough material has been learned about the scattering to allow development of a mathematical model for the interaction of light with blood in a vessel, and this knowledge has been applied to the data reduction of the present oximeter. This data reduction technique has been tested in a controlled experiment employing a model eye with a blood filled mock retinal vessel. It will be shown that the presently developed technique exhibited strong correlation between the known blood oxygen saturation and that calculated by the new system.

  20. Evaluation of double vital staining with lugol's iodine and methylene blue in diagnosing superficial esophageal lesions.

    Science.gov (United States)

    Peng, Guiyong; Long, Qinglin; Wu, Yuwei; Zhao, Jingjing; Chen, Lei; Li, Xianghong

    2011-04-01

    To evaluate the accuracy of double vital staining with lugol's iodine and methylene blue in the diagnosis of superficial esophageal lesions. Doubtful superficial esophageal lesions identified with conventional endoscope were sprayed with 3% lugol's iodine and 0.5% methylene blue in order and observed in detail after each staining. Depending on the mucosal staining, biopsy specimen was obtained and underwent pathological examination. Using conventional endoscope, we found 356 lesions in 297 patients, among which 179 were esophageal squamous cell carcinoma and precancerous lesions (CAPs) (including 71 early esophageal squamous cell carcinoma, 23 esophageal high-grade intraepithelial neoplasias, 85 esophageal low-grade intraepithelial neoplasias) and 177 were non-cancer non-precancerous lesions (NCNPs) (i.e. esophagitis and esophageal squamous cell hyperplasia). Most of CAPs were lightly stained or unstained, while NCNPs were hyperstained after lugol's iodine stained. The specificity, sensitivity, positive predictive value, negative predictive value and accuracy of lugol's lightly stained and unstained for identifying CAPs were 34.5%, 100%, 60.7%, 100% and 67.4%, respectively. Most of CAPs were lightly stained or hyperstained, while NCNPs were unstained after double vital staining. The specificity, sensitivity, positive predictive value, negative predictive value and accuracy of double vital staining lightly stained and hyperstained for identifying CAPs were 97.7%, 100%, 97.8%, 100% and 98.9%, respectively. The accuracy of double vital staining for identifying CAPs was higher than that of lugol's iodine stained (p = 0.000). The double staining with lugol's iodine and methylene blue significantly improves the detection and diagnosis of early esophageal squamous cell CAPs.

  1. Understanding Romanowsky staining. 2. The staining mechanism of suspension-fixed cells, including influences of specimen morphology on the Romanowsky-Giemsa effect.

    Science.gov (United States)

    Horobin, R W; Curtis, D; Pindar, L

    1989-01-01

    Romanowsky staining of suspension-fixed lymphocytes and fibroblasts, deposited as monolayers on slides, involves an initial basic dyeing process followed by formation of a hydrophobic Azur B/Eosin Y complex at the more permeable and so faster staining cellular sites. This mechanism is shared with blood and marrow smears. However certain morphological features peculiar to suspension-fixed, cell culture-derived preparations also influence the staining pattern via rate control: namely the irregular and bulky profiles of fibroblasts, compared to the smoother and thinner lymphocytes; and the occasional superficial occlusion of cells by culture medium.

  2. The evaluation of Lugol's iodine solution staining combined with endoscope for diagnosis of non-erosive reflux disease in clinic.

    Science.gov (United States)

    Zhao, H; Xue, L; Liu, J; Zhang, H-Y; Zhang, D; Song, X-H; He, Y-X; Yang, T; Li, C-Q; Li, Y-Q

    2013-11-01

    To evaluate the value of Lugol's iodine solution staining combined with endoscope on the diagnosis of non-erosive reflux disease (NERD). A total of 96 gastroesophageal reflux disease patients were selected to participate in this study. The patients were stained on esophageal mucosa by Lugol's iodine solution and examined at routine endoscopy. The shallow staining and/or non-staining group patients were treated with esomeprazole and mosapride citrate, and then the changes in Lugol's iodine staining, Gerd Q (Gerd questionnaire) scoring and histological characters of esophageal mucosa were recorded before and after treatment. As the results, a total of 68 patients were diagnosed as NERD, and 36 of 68 patients were observed with uniform staining and 32 of 68 patients were observed with shallow staining and/or non-staining. After 4 weeks for treatment, 28 of 32 patients with shallow staining and/or non-staining became uniform staining and 4 of 32 patients were still with shallow staining and/or non-staining. Before and after treatment, the Gerd Q scoring of uniform staining groups and shallow staining and/or non-staining groups all had a significant difference (p Lugol's iodine solution staining combined with endoscope. Lugol's iodine solution staining combined with routine endoscopy, Gerd Q scoring and histomorphology can be used to evaluate the diagnosis and therapeutic effect of NERD.

  3. Vessel Sewage Discharges: Statutes, Regulations, and Related Laws and Treaties

    Science.gov (United States)

    Vessel sewage discharges can be regulated under multiple statutes, regulations, and laws/treaties, including the Clean Water Act, Title XIV, MARPOL Annex IV and the Vessel General Permit. This page describes how these are applied to vessel sewage.

  4. 49 CFR 176.5 - Application to vessels.

    Science.gov (United States)

    2010-10-01

    ... purpose of carrying flammable or combustible liquid cargo in bulk in its own tanks, when only carrying..., icebreaker, pile driver, pilot boat, welding vessel, salvage vessel, or wrecking vessel; or (8) A foreign...

  5. Merchant marine nuclear-powered vessels

    International Nuclear Information System (INIS)

    Khlopkin, N.S.; Zotov, A.P.

    1997-01-01

    The history of civil nuclear-powered vessels development in Russia is highlighted. Advantages of nuclear propulsion for icebreakers operating in the Arctic are discussed. The operation of nuclear-powered icebreakers and the nuclear lighters-aboard ship in the Arctic has changed the situation on the Northern Sea Way. The all year round navigation there now is a reality. The reliability, safety and ecological cleanness of nuclear-powered vessels are discussed. The necessity of internationally recognized standards, rules and codes for safe operation of nuclear-powered trade vessels is underlined. (orig.)

  6. Structural Analysis of the NCSX Vacuum Vessel

    International Nuclear Information System (INIS)

    Fred Dahlgren; Art Brooks; Paul Goranson; Mike Cole; Peter Titus

    2004-01-01

    The NCSX (National Compact Stellarator Experiment) vacuum vessel has a rather unique shape being very closely coupled topologically to the three-fold stellarator symmetry of the plasma it contains. This shape does not permit the use of the common forms of pressure vessel analysis and necessitates the reliance on finite element analysis. The current paper describes the NCSX vacuum vessel stress analysis including external pressure, thermal, and electro-magnetic loading from internal plasma disruptions and bakeout temperatures of up to 400 degrees centigrade. Buckling and dynamic loading conditions are also considered

  7. A study of reactor vessel integrity assessment

    International Nuclear Information System (INIS)

    Lee, Jae Hoon; Kim, Jong Kyung; Shin, Chang Ho; Seo, Bo Kyun

    1999-02-01

    The fast neutron fluence at the Reactor Pressure Vessel(RPV) of KNGR designed for 60 years lifetime was calculated by full-scope Monte Carlo simulation for reactor vessel integrity assessment. KNGR core geometry was modeled on a three-dimensional representation of the one-sixteenth of the reactor in-vessel component. Each fuel assemblies were modeled explicitly, and each fuel pins were axially divided into 5 segments. The maximum flux of 4.3 x 10 10 neutrons/cm 2 . sec at the RPV was obtained by tallying neutrons crossing the beltline of inner surface of the RPV

  8. Antibiotics for neonates born through meconium-stained amniotic fluid.

    Science.gov (United States)

    Kelly, Lauren E; Shivananda, Sandesh; Murthy, Prashanth; Srinivasjois, Ravisha; Shah, Prakeshkumar S

    2017-06-28

    Approximately 1 in 10 pregnancies is affected by meconium passage at delivery, which can result in meconium aspiration syndrome (MAS). MAS can cause respiratory complications and, very rarely, death. Antibiotics have been prescribed for neonates exposed to meconium in amniotic fluid, with the intention of preventing infection due to potential bacterial contaminants. We conducted this review to assess the efficacy and safety of antibiotics for:1. prevention of infection, morbidity, and mortality among infants born through meconium-stained amniotic fluid (MSAF) who are asymptomatic at birth; and2. prevention of infection, morbidity, and mortality among infants born through MSAF who have signs and symptoms compatible with meconium aspiration syndrome (MAS). We performed a literature search using the following databases: MEDLINE (1966 to July 2016); Embase (1980 to July 2016); the Cumulative Index to Nursing and Allied Health Literature (CINAHL; 1982 to July 2016); and the Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 7) in the Cochrane Library. We also searched clinical trials databases, conference proceedings, and reference lists of retrieved articles. We included randomised and quasi-randomised controlled trials that compared antibiotics administered via any route versus placebo or no treatment for prevention of infection among neonates exposed to MSAF, or who developed MAS. We excluded cohort, case control, and any other non-randomised studies and applied no language restrictions. We included studies of term and preterm infants, and we included studies examining use of any antibacterial antibiotics. We included studies that reported on any outcomes of interest. We assessed the methodological quality of included trials by reviewing information provided in study reports and obtained by personal communication with study authors. We extracted data on relevant outcomes, estimated effect size, and reported values as risk ratios (RRs), risk

  9. Simulation of In-Vessel Corium Retention through External Reactor Vessel Cooling for SMART using SIMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin-Sung; Son, Donggun; Park, Rae-Joon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Thermal load analysis from the corium pool to the outer reactor vessel in the lower plenum of the reactor vessel is necessary to evaluate the effect of the IVR-ERVC during a severe accident for SMART. A computational code called SIMPLE (Sever Invessel Melt Progression in Lower plenum Environment) has been developed for analyze transient behavior of molten corium in the lower plenum, interaction between corium and coolant, and heat-up and ablation of reactor vessel wall. In this study, heat load analysis of the reactor vessel for SMART has been conducted using the SIMPLE. Transient behavior of the molten corium in the lower plenum and IVR-ERVC for SMART has been simulated using SIMPLE. Heat flux from the corium pool to the outer reactor vessel is concentrated in metallic layer by the focusing effect. As a result, metallic layer shows higher temperature than the oxidic layer. Also, vessel wall of metallic layer has been ablated by the high in-vessel temperature. Ex-vessel temperature of the metallic layer was maintained 390 K and vessel thickness was maintained 14 cm. It means that the reactor vessel integrity is maintained by the IVR-ERVC.

  10. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  11. Strong coupling phase in QED

    International Nuclear Information System (INIS)

    Aoki, Ken-ichi

    1988-01-01

    Existence of a strong coupling phase in QED has been suggested in solutions of the Schwinger-Dyson equation and in Monte Carlo simulation of lattice QED. In this article we recapitulate the previous arguments, and formulate the problem in the modern framework of the renormalization theory, Wilsonian renormalization. This scheme of renormalization gives the best understanding of the basic structure of a field theory especially when it has a multi-phase structure. We resolve some misleading arguments in the previous literature. Then we set up a strategy to attack the strong phase, if any. We describe a trial; a coupled Schwinger-Dyson equation. Possible picture of the strong coupling phase QED is presented. (author)

  12. AUTHENTIC MATERIALS IN EXTENSIVE READING CLASS AT STAIN PONOROGO

    Directory of Open Access Journals (Sweden)

    Dhinuk Puspita Kirana

    2013-12-01

    Full Text Available It is widely believed that English Foreign Language (EFL learners need to develop their language proficiency by getting so much input. Moreover, students need to be familiarized with the real English us­age where real forms of communication and cultural knowledge are crucially exposed. Teaching through authentic materials will make the learners feel that they are learning a real language which is used by the real native speakers for real communication. incorporating au­thentic materials helps students acquire an effective communicative competence in the language focus. The research intended to describe the implementation of authentic materials in extensive reading class, the problems arise and the students’ responses toward the authen­tic materials in extensive reading class. The design of the research was Descriptive Qualitative method and the research subject was the lecturer of Extensive Reading class and 33 students in B class of the fourth semester of STAIN Ponorogo who took Extensive Read­ing subject. The instruments used were in the form of observation sheet, interview guideline and questionnaire. The implementation of authentic materials in extensive reading class covered some procedures into three main phases namely (1 Pre­ Activity, (2 Main­ Activity and (3 Post­Activity. The activities in main activity are as follows: (a Pre­ Activity; (b Whilst ­Activity; and (3 The language focus stage. There were problems arose during the implementation in terms of complicated planning, more time allocation and some disinterested students. Finally, the students showed significantly positive attitude toward the implementation of authentic materials in extensive reading class.

  13. Periocular port wine stain: the great ormond street hospital experience.

    Science.gov (United States)

    Khaier, Ayman; Nischal, Ken K; Espinosa, Marcela; Manoj, Bal

    2011-11-01

    To identify the sensitivity and specificity of risk factors for the development of glaucoma in patients with port wine stain (PWS). A retrospective case-control study involving a large cohort of patients with PWS. A total of 216 patients (total of 252 eyes) with unilateral or bilateral PWS seen in the eye department in Great Ormond Street Hospital, London, United Kingdom. We studied the anatomic distribution of PWS and the incidence of choroidal hemangioma, episcleral hemangioma, iris heterochromia, and Sturge-Weber syndrome (SWS). We analyzed the sensitivity and specificity of these features as risk factors for glaucoma. Development of glaucoma. Mean age at presentation was 2.9 years (3 weeks to 18.8 years). Mean follow-up was 3.2 years (0-15 years). A total of 180 patients (83.3%) had unilateral lesion, and 36 patients (16.7%) had bilateral lesion. Thirty-one patients (14.3%) had isolated V1 lesion, 35 patients had V2 lesion only (16.2%), and 93 patients (43%) had both V1 and V2 involved. On the last visit, 46 eyes (18.3%) in 39 patients had glaucoma; their mean age was 3.25 years. Glaucoma was more common if PWS was bilateral (P=0.0001), both upper and lower lids were involved (P heterochromia (P=0.004), or choroidal hemangioma (P heterochromia are sensitive prognosticators for the development of glaucoma. Iris heterochromia is associated with the development of early glaucoma in patients with PWS. Patients at high risk of glaucoma should be seen more often in clinic. Patients who do not have combined lid involvement or episcleral hemangioma have a lower risk and can therefore be seen less often in clinic. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Design of Saddle Support for Horizontal Pressure Vessel

    OpenAIRE

    Vinod Kumar; Navin Kumar; Surjit Angra; Prince Sharma

    2014-01-01

    This paper presents the design analysis of saddle support of a horizontal pressure vessel. Since saddle have the vital role to support the pressure vessel and to maintain its stability, it should be designed in such a way that it can afford the vessel load and internal pressure of the vessel due to liquid contained in the vessel. A model of horizontal pressure vessel and saddle support is created in ANSYS. Stresses are calculated using mathematical approach and ANSYS soft...

  15. Utility of Acridine Orange staining for detection of bacteria from positive blood cultures.

    Science.gov (United States)

    Neeraja, M; Lakshmi, V; Padmasri, C; Padmaja, K

    2017-08-01

    The diagnostic performance of AO stain was evaluated for the detection of bacteria and or fungi from positive blood cultures. The sensitivity of Gram stain (GS) was 98.26% while Acridine Orange (AO) stain proved to be more sensitive (100%) with a Positive and Negative Predictive Value of 100% each. The specificity of both the stains was 100%. Overall agreement between the two stains was 98.23% (688/700). The organisms that were missed by GS and positive by AO were Candida species (Sutton, 2006) and Gram negative bacilli (GNB) (Sutton, 2006). Sensitivity of GS was 82.35% and AO was 100% among mixed cultures. Immediate reporting of the results of AO stain would have a significant impact on clinical management of patients with serious blood stream infections. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Understanding microwave-stimulated Romanowsky--Giemsa staining of plastic embedded bone marrow.

    Science.gov (United States)

    Horobin, R W; Boon, M E

    1988-01-01

    Bone marrow smears were made and fixed in methanol or formaldehyde. Marrow sections of various thicknesses were also prepared from formaldehyde fixed marrows embedded in paraffin or plastic (glycol methacrylate). The different smears and sections were then stained by a Romanowsky--Giemsa procedure. Some specimens were stained using a standard microwave-stimulated method previously used diagnostically. The effects of technical variations were studied, including degree of microwave irradiation and the staining time. Comparisons of the resulting staining outcomes showed that microwave stimulated Romanowsky--Giemsa staining of plastic sections is a rate controlled process. Unusual aspects of the staining pattern of plastic sections (namely the purple basophilic cytoplasms and nucleoli, and blue chromatin) are due to microwave stimulation and formaldehyde fixation respectively.

  17. Can examination of tissue stained with Oil red O be postponed up to three months?

    Directory of Open Access Journals (Sweden)

    Christoffersen Simone Dorthea

    2014-12-01

    Full Text Available Introduction: As far as we know, there are no known studies on the durability of frozen tissue stained with Oil Red O. The purpose of this study was to examine if the lipid drops in Oil Red O stained tissue keep the original position and color over time (3 months. Further we examined if storage position of the stained tissue makes a difference. Method: We used ten frozen kidney sections stained with Oil Red O. Half of the samples were stored vertically and the other half horizontally, and photos of the same areas were taken within the first 24 hours after staining, and then after 48 hours, 72 hours, 7 days, 14 days, 1 month, 2 months and 3 months respectively. Results and conclusion: No changes in position of the lipids were observed. The color of the staining faded somewhat over time, but it was still possible to distinguish the positive sites from the negative.

  18. A photoelastic study of the effects of an impulsive seismic wave on a nuclear containment vessel

    International Nuclear Information System (INIS)

    Burger, C.P.

    1981-01-01

    A dynamic photoelastic study of the progressive movement of a dilatational P-wave into a model of a nuclear containment vessel,is studied. The reflections at the dome abutments are observed and the strong flexural wave that deforms the dome itself is studied with photoelasticity and with dynamic strain gage procedures. (E.G.) [pt

  19. Progress on the design development and prototype manufacturing of the ITER In-vessel coils

    NARCIS (Netherlands)

    Encheva, A.; Omran, H.; Devred, A.; Vostner, A.; Mitchell, N.; Mariani, N.; Jun, CH H.; Long, F.; Zhou, C.; Macklin, B.; Marti, H. P.; Sborchia, C.; della Corte, A. Della; Di Zenobio, A.; Anemona, A.; Righetti, R.; Wu, Y.; Jin, H.; Xu, A.; Jin, J.

    2017-01-01

    ITER is incorporating two types of In-Vessel Coils (IVCs): ELM Coils to mitigate Edge Localized Modes and VS Coils to provide a reliable Vertical Stabilization of the plasma. Strong coupling with the plasma is required in order that the ELM and VS Coils can meet their performance requirements.

  20. Wine vessels (Vasa vinaria in roman law

    Directory of Open Access Journals (Sweden)

    Aličić Samir

    2017-01-01

    Full Text Available The notion of 'wine vessels' in Roman law comprises all the winecontaining recipients. There is no legal standardization of wine vessels by means of volume, and although the terms amphora, urna and culleus are used to designate both the vessels and the units of measure, these are two different meanings of the terms. In regard of the question, whether the vessels make appurtenance of the wine, jurisprudents of proculean school divided them in two categories. In the first category are those that follow legal status of wine, usually amphoras and other jars (cadi which are used for 'packaging', i. e. 'bottling' of the wine. The second category make mostly vats (cuppae and ceramic cisterns (dolia, which don't follow legal status of wine, making instead part of farming equipment of a landed property (instrumentum fundi and it's appurtenance. But, the roman jurists are not consistent regarding criteria for distinguishing these two categories.