WorldWideScience

Sample records for strongly stained vessels

  1. Modeling the color perception of port wine stains and its relation to the depth of laser coagulated blood vessels

    NARCIS (Netherlands)

    Lakmaker, O.; Pickering, J. W.; van Gemert, M. J.

    1993-01-01

    To find the maximal depth of an ecstatic vessel in the dermis that contributes to the abnormal color of a port wine stain (PWS), "normal" and "laser treated PWS skin" are modeled, respectively, as a two-layer plane parallel geometry consisting of an epidermis and a dermis, and as a three-layer

  2. Infrared tomography for diagnostic imaging of port wine stain blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Goodman, D. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    The objective of this work is the development of Infrared Tomography (IRT) for detecting and characterizing subsurface chromophores in human skin. Characterization of cutaneous chromophores is crucial for advances in the laser treatment of pigmented lesions (e.g., port wine stain birthmarks and tatoos). Infrared tomography (IRT) uses a fast infrared focal plane array (IR-FPA) to detect temperature rises in a substrate induced by pulsed radiation. A pulsed laser is used to produce transient heating of an object. The temperature rise, due to the optical absorption of the pulsed laser light, creates an increase in infrared emission which is measured by the IR-FPA. Although the application of IRT to image subsurface cracks due to metal fatigue is a topic of great interest in the aircraft industry, the application to image subsurface chromophores in biological materials is novel. We present an image recovery method based on a constrained conjugate gradient algorithm that has obtained the first ever high quality images of port wine blood vessels.

  3. A three-temperature model of selective photothermolysis for laser treatment of port wine stain containing large malformed blood vessels

    International Nuclear Information System (INIS)

    Li, D.; Wang, G.X.; He, Y.L.; Wu, W.J.; Chen, B.

    2014-01-01

    As congenital vascular malformations, port wine stain (PWS) is composed of ectatic venular capillary blood vessels buried within healthy dermis. In clinic, pulsed dye laser (PDL) in visible band (e.g. 585 nm) together with cryogen spray cooling (CSC) have become the golden standard for treatment of PWS. However, due to the limited energy deposition of the PDL in blood, large blood vessels are likely to survive from the laser irradiation. As a result, complete clearance of the lesions is rarely achieved. Assuming the local thermal non-equilibrium in skin tissue during the laser surgery, a three-temperature model is proposed to treat the PWS tissue as a porous media composed of a non-absorbing dermal matrix buried with the blood as well as the large malformed blood vessels. Three energy equations are constructed and solved coupling for the temperature of the blood in average-sized PWS vessels, non-absorbing dermal tissues and large malformed blood vessels, respectively. Subsequently, the thermal responses of human skin to visible (585 nm) and near-infrared (1064 nm) laser irradiations with various pulse durations in conjunction with cryogen spray cooling are investigated by the new model, and Arrhenius integral is used to analyze the thermal damage. The simulations show that the short pulse duration of 1.5 ms results in a higher selective heating of blood over epidermis, which will lead to a desired clinic outcome than the longer pulse duration. Due to a much deeper light penetration depth, laser irradiation with 1064 nm in wavelength is superior to that with 585 nm in treating patients with cutaneous hyper-vascular malformation. Complete coagulations are predicted in large-sized and deeply extending blood vessels by 1064 nm laser. - Highlights: •A three-temperature model is proposed for the laser treatment of port wine stain (PWS). •Average sized and large malformed blood vessels in porous medium (tissue) are considered. •Thermal responses of PWS to

  4. Light distributions in a port wine stain model containing multiple cylindrical and curved blood vessels

    NARCIS (Netherlands)

    Lucassen, G. W.; Verkruysse, W.; Keijzer, M.; van Gemert, M. J.

    1996-01-01

    Knowledge of the light distribution in skin tissue is important for the understanding, prediction, and improvement of the clinical results in laser treatment of port wine stains (PWS). The objective of this study is to improve modelling of PWS treated by laser using an improved and more realistic

  5. Compared With Elastin Stains, h-Caldesmon and Desmin Offer Superior Detection of Vessel Invasion in Gastric, Pancreatic, and Colorectal Adenocarcinomas.

    Science.gov (United States)

    Ekinci, Özgür; Öğüt, Betül; Çelik, Bülent; Dursun, Ayşe

    2018-06-01

    The presence of vessel invasion is considered indicative of a poor prognosis in many malignant tumors. We aimed to compare the sensitivity of elastin stains (van Gieson's and orcein methods) with 2 smooth muscle markers (h-caldesmon and desmin) in gastric, pancreatic, and colorectal adenocarcinoma specimens. We used 27 (29.3%) gastric, 35 (38.0%) pancreatic, and 30 (32.6%) colorectal resection specimens. We applied a provisional classification of vessel invasion patterns: type A, a focus with a nearby artery unaccompanied by a vein; type T, a focus at the invasive front without an unaccompanied artery; and type X, foci that only appeared by any of the 4 stains used. There were 369 foci. The smooth muscle markers were more sensitive than the elastin stains, and h-caldesmon more sensitive than desmin, in all types. Among the 139 type A foci, 33 (23.7%) were positive by desmin and h-caldesmon, whereas the elastin stains were not ( P = .001). h-Caldesmon was the only positive marker in 11 (7.9%; P = .011). Among the 78 type T foci, 21 (26.9%) were positive by desmin and h-caldesmon, when both elastin stains were negative ( P = .000). In 16 (20.5%) foci, h-caldesmon was the only positive marker ( P = .002). Among 152 type X foci, 91 (59.9%) were positive by all markers, 26 (17.1%) by both desmin and h-caldesmon, and 9 (5.9%) by only the 2 elastin stains ( P = .001). We recommend these stains for suspect foci in gastric, pancreatic, and colorectal adenocarcinoma specimens. They might highlight both predictable and unpredictable foci.

  6. Safety analysis of nuclear containment vessels subjected to strong earthquakes and subsequent tsunamis

    Directory of Open Access Journals (Sweden)

    Feng Lin

    2017-08-01

    Full Text Available Nuclear power plants under expansion and under construction in China are mostly located in coastal areas, which means they are at risk of suffering strong earthquakes and subsequent tsunamis. This paper presents a safety analysis for a new reinforced concrete containment vessel in such events. A finite element method-based model was built, verified, and first used to understand the seismic performance of the containment vessel under earthquakes with increased intensities. Then, the model was used to assess the safety performance of the containment vessel subject to an earthquake with peak ground acceleration (PGA of 0.56g and subsequent tsunamis with increased inundation depths, similar to the 2011 Great East earthquake and tsunami in Japan. Results indicated that the containment vessel reached Limit State I (concrete cracking and Limit State II (concrete crushing when the PGAs were in a range of 0.8–1.1g and 1.2–1.7g, respectively. The containment vessel reached Limit State I with a tsunami inundation depth of 10 m after suffering an earthquake with a PGA of 0.56g. A site-specific hazard assessment was conducted to consider the likelihood of tsunami sources.

  7. Safety analysis of nuclear containment vessels subjected to strong earthquakes and subsequent tsunamis

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Feng; Li, Hong Zhi [Dept. Structural Engineering, Tongji University, Shanghai (China)

    2017-08-15

    Nuclear power plants under expansion and under construction in China are mostly located in coastal areas, which means they are at risk of suffering strong earthquakes and subsequent tsunamis. This paper presents a safety analysis for a new reinforced concrete containment vessel in such events. A finite element method-based model was built, verified, and first used to understand the seismic performance of the containment vessel under earthquakes with increased intensities. Then, the model was used to assess the safety performance of the containment vessel subject to an earthquake with peak ground acceleration (PGA) of 0.56g and subsequent tsunamis with increased inundation depths, similar to the 2011 Great East earthquake and tsunami in Japan. Results indicated that the containment vessel reached Limit State I (concrete cracking) and Limit State II (concrete crushing) when the PGAs were in a range of 0.8–1.1g and 1.2–1.7g, respectively. The containment vessel reached Limit State I with a tsunami inundation depth of 10 m after suffering an earthquake with a PGA of 0.56g. A site-specific hazard assessment was conducted to consider the likelihood of tsunami sources.

  8. Intravenous injection of artificial red cells and subsequent dye laser irradiation causes deep vessel impairment in an animal model of port-wine stain.

    Science.gov (United States)

    Rikihisa, Naoaki; Tominaga, Mai; Watanabe, Shoji; Mitsukawa, Nobuyuki; Saito, Yoshiaki; Sakai, Hiromi

    2018-03-15

    Our previous study proposed using artificial blood cells (hemoglobin vesicles, Hb-Vs) as photosensitizers in dye laser treatment for port-wine stains (PWSs). Dye laser photons are absorbed by red blood cells (RBCs) and hemoglobin (Hb) mixture, which potentially produce more heat and photocoagulation and effectively destroy endothelial cells. Hb-Vs combination therapy will improve clinical outcomes of dye laser treatment for PWSs because very small vessels do not contain sufficient RBCs and they are poor absorbers/heaters of lasers. In the present study, we analyzed the relationship between vessel depth from the skin surface and vessel distraction through dye laser irradiation following intravenous Hb-Vs injection using a chicken wattle model. Hb-Vs were administered and chicken wattles underwent high-energy irradiation at energy higher than in the previous experiments. Hb-Vs location in the vessel lumen was identified to explain its photosensitizer effect using human Hb immunostaining of the irradiated wattles. Laser irradiation with Hb-Vs can effectively destroy deep vessels in animal models. Hb-Vs tend to flow in the marginal zone of both small and large vessels. Increasing laser power combined with Hb-Vs injection contributed for deep vessel impairment because of the synergetic effect of both methods. Newly added Hb tended to flow near the target endothelial cells of the laser treatment. In Hb-Vs and RBC mixture, heat transfer to endothelial cells from absorbers/heater may increase. Hb-Vs function as photosensitizers to destroy deep vessels within a restricted distance that the photon can reach.

  9. Sensitivity of Helicobacter pylori detection by Giemsa staining is poor in comparison with immunohistochemistry and fluorescent in situ hybridization and strongly depends on inflammatory activity.

    Science.gov (United States)

    Kocsmár, Éva; Szirtes, Ildikó; Kramer, Zsófia; Szijártó, Attila; Bene, László; Buzás, György Miklós; Kenessey, István; Bronsert, Peter; Csanadi, Agnes; Lutz, Lisa; Werner, Martin; Wellner, Ulrich Friedrich; Kiss, András; Schaff, Zsuzsa; Lotz, Gábor

    2017-08-01

    Conventional stainings (including H&E and special stains like Giemsa) are the most widely applied histopathologic detection methods of Helicobacter pylori (HP). We aimed to compare the diagnostic performance of Giemsa staining with immunohistochemistry (IHC) and fluorescent in situ hybridization (FISH) on a monocentric cohort of 2896 gastric biopsies and relate results to histologic alterations in order to find such histopathologic subgroups in which these methods underperform. All cases were categorized regarding presence or absence of chronic gastritis, inflammatory activity, and mucosal structural alterations. Giemsa revealed 687 cases (23.7%), IHC 795 cases (27.5%), and FISH 788 cases (27.2%) as being HP positive. Giemsa showed significantly lower overall sensitivity (83.3%) compared to IHC (98.8%) and FISH (98.0%). Moreover, the sensitivity of Giemsa dramatically dropped to 33.6% in the nonactive cases. We found that sensitivity of Giemsa strongly depends on HP density and, accordingly, on the presence of activity. Structural alterations (intestinal metaplasia, atrophy, etc.) had only no or weak effect on sensitivity of the three stainings. Both IHC and FISH proved to be equally reliable HP detecting techniques whose diagnostic performance is minimally influenced by mucosal inflammatory and structural alterations contrary to conventional stainings. We highly recommend immunohistochemistry for clinically susceptible, nonactive chronic gastritis cases, if the conventional stain-based HP detection is negative. Moreover, we recommend to use IHC more widely as basic HP stain. Helicobacter pylori FISH technique is primarily recommended to determine bacterial clarithromycin resistance. Furthermore, it is another accurate diagnostic tool for HP. © 2017 John Wiley & Sons Ltd.

  10. Gram staining.

    Science.gov (United States)

    Coico, Richard

    2005-10-01

    Named after Hans Christian Gram who developed the method in 1884, the Gram stain allows one to distinguish between Gram-positive and Gram-negative bacteria on the basis of differential staining with a crystal violet-iodine complex and a safranin counterstain. The cell walls of Gram-positive organisms retain this complex after treatment with alcohol and appear purple, whereas gram-negative organisms decolorize following such treatment and appear pink. The method described here is useful for assessing bacterial contamination of tissue culture samples or for examining the Gram stain status and morphological features of bacteria isolated from mixed or isolated bacterial cultures.

  11. Influence of heat treatments on thermoelectric power of pressure vessel steels: effect of microstructural evolutions of strongly segregated areas

    International Nuclear Information System (INIS)

    Houze, M.

    2002-12-01

    Thermoelectric power measurement (TEP) is a very potential non destructive evaluation method considered to follow ageing under neutron irradiation of pressure vessel steel of nuclear reactor. Prior to these problems, the aim of this study is to establish correlations between TEP variations and microstructural evolutions of pressure vessel steels during heat treatments. Different steels, permitting to simulate heterogeneities of pressure vessel steels and to deconvoluate main metallurgical phenomenons effects were studied. This work allowed to emphasize effect on TEP of: austenitizing and cooling conditions and therefore of microstructure, metallurgical transformations during tempering (recovery, precipitation of alloying elements), and particularly molybdenum precipitation associated to secondary hardening, residual austenite amount or partial austenitizing. (author)

  12. Cholinergic innervation of human mesenteric lymphatic vessels.

    Science.gov (United States)

    D'Andrea, V; Bianchi, E; Taurone, S; Mignini, F; Cavallotti, C; Artico, M

    2013-11-01

    The cholinergic neurotransmission within the human mesenteric lymphatic vessels has been poorly studied. Therefore, our aim is to analyse the cholinergic nerve fibres of lymphatic vessels using the traditional enzymatic techniques of staining, plus the biochemical modifications of acetylcholinesterase (AChE) activity. Specimens obtained from human mesenteric lymphatic vessels were subjected to the following experimental procedures: 1) drawing, cutting and staining of tissues; 2) staining of total nerve fibres; 3) enzymatic staining of cholinergic nerve fibres; 4) homogenisation of tissues; 5) biochemical amount of proteins; 6) biochemical amount of AChE activity; 6) quantitative analysis of images; 7) statistical analysis of data. The mesenteric lymphatic vessels show many AChE positive nerve fibres around their wall with an almost plexiform distribution. The incubation time was performed at 1 h (partial activity) and 6 h (total activity). Moreover, biochemical dosage of the same enzymatic activity confirms the results obtained with morphological methods. The homogenates of the studied tissues contain strong AChE activity. In our study, the lymphatic vessels appeared to contain few cholinergic nerve fibres. Therefore, it is expected that perivascular nerve stimulation stimulates cholinergic nerves innervating the mesenteric arteries to release the neurotransmitter AChE, which activates muscarinic or nicotinic receptors to modulate adrenergic neurotransmission. These results strongly suggest, that perivascular cholinergic nerves have little or no effect on the adrenergic nerve function in mesenteric arteries. The cholinergic nerves innervating mesenteric arteries do not mediate direct vascular responses.

  13. Behavior of platelets stained by 5,6-CF-encapsulated PEGylated liposomes after laser irradiation of vessel wall: an in-vivo model for studying site-selective delivery of diagnostic or therapeutic agents

    Science.gov (United States)

    Mordon, Serge R.; Begu, Sylvie; Buys, Bruno; Tourne-Peteilh, Corine; Devoisselle, Jean-Marie

    2001-05-01

    Vascular endothelium serves as an extensive interface between circulating blood and various tissues and organs of the body. As such, it offers an accessible target for blood-borne pharmacological and genetic manipulations that can mediate both local and systemic effects. Thus, targeting of liposomes to activated vascular endothelial cells may provide a strategy for site-selective delivery in the vascular system with broad therapeutic applicability. This study aimed to evaluate an intravital fluorescence imaging technique to visualize in-situ and in real-time the activation of platelets after staining by 5,6-CF- encapsulated PEGylated liposomes injected intravenously. The study was performed on skin by using a dorsal skin-fold chamber implanted in golden hamsters using intravital microscopy. The skin micro circulation was observed with an intravital microscope (using x25 and x40 magnification) fitted with a Xenon light source and an epi-fluorescence assembly. An ultra-high sensitivity video-camera mounted on the microscope projected the image onto a monitor, and the images were recorded for play-back analysis with a digital video cassette recorder. An inflammatory response was induced by an Argon laser emitting at 514.5nm. The 80micrometers laser beam was focused on a vessel and its position was controlled with the microscope imaging system, it was possible to see individual platelets flowing in blood vessels. As liposomes were labeled with a fluorescent probe which was hydrophilic (located in the aqueous phase), the fluorescence of platelets was due only to the uptake of liposomes. After laser irradiation, platelets activation at sites of vascular injury was obtained. Tethering, translocation of some platelets inside the irradiated zone were clearly seen. At last, detachment and extravasation of platelets were observed. A perivascular fluorescence confirmed that platelets migrated across the basal lamina into the dermal connective tissue. In conclusion, staining of

  14. Differential staining of bacteria: gram stain.

    Science.gov (United States)

    Moyes, Rita B; Reynolds, Jackie; Breakwell, Donald P

    2009-11-01

    In 1884, Hans Christian Gram, a Danish doctor, developed a differential staining technique that is still the cornerstone of bacterial identification and taxonomic division. This multistep, sequential staining protocol separates bacteria into four groups based on cell morphology and cell wall structure: Gram-positive cocci, Gram-negative cocci, Gram-positive rods, and Gram-negative rods. The Gram stain is useful for assessing bacterial contamination of tissue culture samples or for examining the Gram stain status and morphological features of bacteria isolated from mixed or isolated bacterial cultures. (c) 2009 by John Wiley & Sons, Inc.

  15. Blood vessels in subcaruncular and intercaruncular bovine endometriun possess oxytocin receptors (ORT) and express otr mRNA during pregnancy

    DEFF Research Database (Denmark)

    Fuchs, Anna-Ritta; Balvers, Marga; Ivell, Richard

    2002-01-01

    is taking place; marked changes were observed with advancing pregnancy. The epithelial cells of the trophoblast were strongly stained for ir OTR and OTR mRNA, as reported last year, but the fetal connective tissue and blood vessels within the trophoblast did not show any stain for ir OTR or OTR m...... placentation because episodic secretion of OT occurs throughout bovine pregnancy...

  16. Port-Wine Stains

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Port-Wine Stains KidsHealth / For Parents / Port-Wine Stains What's ... Manchas de vino de oporto What Are Port-Wine Stains? A port-wine stain is a type ...

  17. leaves extracts as counter stain in gram staining reaction 56

    African Journals Online (AJOL)

    DR. AMINU

    is a stain with color contrasting to the principal stain, making the stained ... technology today, the Gram's staining method remains ... was aimed at employing the use of Henna leaves extract as ... fragrant, white or rose flowers in clusters. It is.

  18. Differential staining of bacteria: acid fast stain.

    Science.gov (United States)

    Reynolds, Jackie; Moyes, Rita B; Breakwell, Donald P

    2009-11-01

    Acid-fastness is an uncommon characteristic shared by the genera Mycobacterium (Section 10A) and Nocardia. Because of this feature, this stain is extremely helpful in identification of these bacteria. Although Gram positive, acid-fast bacteria do not take the crystal violet into the wall well, appearing very light purple rather than the deep purple of normal Gram-positive bacteria. (c) 2009 by John Wiley & Sons, Inc.

  19. Iron Stain on Wood

    Science.gov (United States)

    Mark Knaebe

    2013-01-01

    Iron stain, an unsightly blue–black or gray discoloration, can occur on nearly all woods. Oak, redwood, cypress, and cedar are particularly prone to iron stain because these woods contain large amounts of tannin-like extractives. The discoloration is caused by a chemical reaction between extractives in the wood and iron in steel products, such as nails, screws, and...

  20. Lasers or light sources for treating port-wine stains

    DEFF Research Database (Denmark)

    Faurschou, Annesofie; Olesen, Anne Braae; Leonardi-Bee, Jo

    2011-01-01

    Port-wine stains are birthmarks caused by malformations of blood vessels in the skin. Port-wine stains manifest themselves in infancy as a flat, red mark and do not regress spontaneously but may, if untreated, become darker and thicker in adult life. The profusion of various lasers and light...

  1. Laser beam diameter for port wine stain treatment

    NARCIS (Netherlands)

    Keijzer, M.; Pickering, J. W.; van Gemert, M. J.

    1991-01-01

    Optimal port wine stain treatment requires the selective absorption of light by the ectatic blood vessels. We investigated whether deeper blood vessels can be coagulated, without damaging other cutaneous structures, by varying the laser beam diameter. The penetration of the light was simulated with

  2. Discriminative staining methods for the nervous system: luxol fast blue--periodic acid-Schiff--hematoxylin triple stain and subsidiary staining methods.

    Science.gov (United States)

    Goto, N

    1987-09-01

    This paper describes a new series of staining methods which can discriminatively demonstrate every structure of the nervous system, including axons and capillaries, in animal and human materials. Methods described in this paper consist of one primary stain, luxol fast blue-periodic acid Schiff-hematoxylin (LPH) and six different subsidiary staining methods. The LPH triple stain can precisely differentiate the following structures: neurons (Nissl bodies, cytoplasm, nuclear membrane and nucleolus), various kinds of nuclei (glia, ependyma, endothelium, leucocyte, connective tissue, etc.), myelin sheaths, neuronal processes (axons and dendrites), reacted glial cell bodies (protoplasmic astrocytes, foamy cells, etc.), blood vessels (arteries, veins and capillaries), meninges, intervening connective tissue, erythrocytes, lipofuscin granules, amyloid bodies, and others. Subsidiary staining methods are also described briefly. Applications are discussed in the context of staining technology and neuromorphological research.

  3. Port-wine stain

    Science.gov (United States)

    ... About MedlinePlus Show Search Search MedlinePlus GO GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Port-wine stain URL of this page: //medlineplus.gov/ency/ ...

  4. Stool Gram stain

    Science.gov (United States)

    ... stool sample. The Gram stain method is sometimes used to quickly diagnose bacterial infections. How the Test is Performed You will need to collect a stool sample. There are many ways to collect the sample. You can catch the stool on plastic wrap that is loosely placed over the toilet bowl ...

  5. Stained Glass and Flu

    Centers for Disease Control (CDC) Podcasts

    2017-02-01

    Dr. Robert Webster, an Emeritus member of the Department of Infectious Diseases at St. Jude Children's Research Hospital, discusses his cover art story on stained glass and influenza.  Created: 2/1/2017 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 2/1/2017.

  6. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  7. Modified Field's staining--a rapid stain for Trichomonas vaginalis.

    Science.gov (United States)

    Afzan, M Yusuf; Sivanandam, S; Kumar, G Suresh

    2010-10-01

    Trichomonas vaginalis, a flagellate protozoan parasite commonly found in the human genitourinary tract, is transmitted primarily by sexual intercourse. Diagnosis is usually by in vitro culture method and staining with Giemsa stain. There are laboratories that use Gram stain as well. We compared the use of modified Field's (MF), Giemsa, and Gram stains on 2 axenic and xenic isolates of T. vaginalis, respectively. Three smears from every sediment of spun cultures of all 4 isolates were stained, respectively, with each of the stains. We showed that MF staining, apart from being a rapid stain (20 s), confers sharper staining contrast, which differentiates the nucleus and the cytoplasm of the organism when compared to Giemsa and Gram staining especially on parasites from spiked urine samples. The alternative staining procedure offers in a diagnostic setting a rapid stain that can easily visualize the parasite with sharp contrasting characteristics between organelles especially the nucleus and cytoplasm. Vacuoles are more clearly visible in parasites stained with MF than when stained with Giemsa. Copyright © 2010 Elsevier Inc. All rights reserved.

  8. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    The role of the research vessels as a tool for marine research and exploration is very important. Technical requirements of a suitable vessel and the laboratories needed on board are discussed. The history and the research work carried out...

  9. Say goodbye to coffee stains

    NARCIS (Netherlands)

    Eral, Burak; van den Ende, Henricus T.M.; Mugele, Friedrich Gunther

    2012-01-01

    Discussing ideas over a mug of coffee or tea is the lifeblood of science, but have you ever thought about the stains that can be inadvertently left behind? H Burak Eral, Dirk van den Ende and Frieder Mugele explain how these stains, which can be a major annoyance in some biology techniques, can be

  10. Factors influencing extract of Hibiscus sabdariffa staining of rat testes.

    Science.gov (United States)

    Bassey, R B; Bakare, A A; Peter, A I; Oremosu, A A; Osinubi, A A

    2012-08-01

    Some plant extracts can be used in biology and medicine to reveal or identify cellular components and tissues. We investigated the effects of time and concentration on staining of histological sections of rat testes by an acidified extract of Hibiscus sabdariffa. An ethanolic extract of H. sabdariffa was diluted using 1% acetic acid in 70% ethanol to stain histological sections of testes at concentrations of 0.2, 0.1 and 0.05 g/ml for 5, 10, 15, 30, 45 and 60 min. The sections of testes were stained deep red. The staining efficiency of H. sabdariffa was greater at a high concentration and required less time to achieve optimal staining. H. sabdariffa is a strongly basic dye that can be used for various diagnostic purposes. Staining time and concentration must be considered to achieve optimal results.

  11. Metabolic markers in relation to hypoxia; staining patterns and colocalization of pimonidazole, HIF-1α, CAIX, LDH-5, GLUT-1, MCT1 and MCT4

    International Nuclear Information System (INIS)

    Rademakers, Saskia E; Lok, Jasper; Kogel, Albert J van der; Bussink, Johan; Kaanders, Johannes HAM

    2011-01-01

    The cellular response of malignant tumors to hypoxia is diverse. Several important endogenous metabolic markers are upregulated under hypoxic conditions. We examined the staining patterns and co-expression of HIF-1α, CAIX, LDH-5, GLUT-1, MCT1 and MCT4 with the exogenous hypoxic cell marker pimonidazole and the association of marker expression with clinicopathological characteristics. 20 biopsies of advanced head and neck carcinomas were immunohistochemically stained and analyzed. All patients were given the hypoxia marker pimonidazole intravenously 2 h prior to biopsy taking. The tumor area positive for each marker, the colocalization of the different markers and the distribution of the markers in relation to the blood vessels were assessed by semiautomatic quantitative analysis. MCT1 staining was present in hypoxic (pimonidazole stained) as well as non-hypoxic areas in almost equal amounts. MCT1 expression showed a significant overall correlation (r = 0.75, p < 0.001) and strong spatial relationship with CAIX. LDH-5 showed the strongest correlation with pimonidazole (r = 0.66, p = 0.002). MCT4 and GLUT-1 demonstrated a typical diffusion-limited hypoxic pattern and showed a high degree of colocalization. Both MCT4 and CAIX showed a higher expression in the primary tumor in node positive patients (p = 0.09 both). Colocalization and staining patterns of metabolic and hypoxia-related proteins provides valuable additional information over single protein analyses and can improve the understanding of their functions and environmental influences

  12. Nuclear staining with alum hematoxylin.

    Science.gov (United States)

    Llewellyn, B D

    2009-08-01

    The hematoxylin and eosin stain is the most common method used in anatomic pathology, yet it is a method about which technologists ask numerous questions. Hematoxylin is a natural dye obtained from a tree originally found in Central America, and is easily converted into the dye hematein. This dye forms coordination compounds with mordant metals, such as aluminum, and the resulting lake attaches to cell nuclei. Regressive formulations contain a higher concentration of dye than progressive formulations and may also contain a lower concentration of mordant. The presence of an acid increases the life of the solution and in progressive solutions may also affect selectivity of staining. An appendix lists more than 60 hemalum formulations and the ratio of dye to mordant for each.

  13. Etika Berbusana Mahasiswa Stain Samarinda

    Directory of Open Access Journals (Sweden)

    Ida Suryani Wijaya

    2012-06-01

    Full Text Available Ethics is about behavior of human being, such as which one is right or wrong. The ethics is always affecting the human life. The ethics gives people orientation how he/she do manything every time every day. Islamic ethics consists of the way how someone interact each other; how someone should do or not to do, how to sit, how to walk, how to eat or drink, how to sleep, or how to get dressed. Al-Qur’an uses three terms to define about dressing, they are: libas, tsiyah, and sarahi. Dressing has a function as covering the body, as assessoris, as the way to do Islamic taqwa, and as an identiy. Dressing ethics of the female students of STAIN Samarinda has been regulated by the rector regulation No 19 of the year 2002 about relation and dressing ethics for the students of STAIN Samarinda.

  14. Accelerated staining technique using kitchen microwave oven

    Directory of Open Access Journals (Sweden)

    Archana Mukunda

    2015-01-01

    Full Text Available Introduction: Histopathological diagnosis of specimens is greatly dependent on good sample preparation and staining. Both of these processes is governed by diffusion of fluids and dyes in and out of the tissue, which is the key to staining. Diffusion of fluids can be accelerated by the application of heat that reduces the time of staining from hours to the minute. We modified an inexpensive model of kitchen microwave oven for staining. This study is an attempt to compare the reliability of this modified technique against the tested technique of routine staining so as to establish the kitchen microwave oven as a valuable diagnostic tool. Materials and Methods: Sixty different tissue blocks were used to prepare 20 pairs of slides for 4 different stains namely hematoxylin and eosin, Van Gieson′s, 0.1% toluidine blue and periodic acid-Schiff. From each tissue block, two bits of tissues were mounted on two different slides. One slide was stained routinely, and the other stained inside a microwave. A pathologist evaluated the stained slides and the results so obtained were analyzed statistically. Results: Microwave staining considerably cut down the staining time from hours to seconds. Microwave staining showed no loss of cellular and nuclear details, uniform-staining characteristics and was of excellent quality. Interpretation and Conclusion: The cellular details, nuclear details and staining characteristics of microwave stained tissues were better than or equal to the routine stained tissue. The overall quality of microwave-stained sections was found to be better than the routine stained tissue in majority of cases.

  15. Containment vessel

    International Nuclear Information System (INIS)

    Zbirohowski-Koscia, K.F.; Roberts, A.C.

    1980-01-01

    A concrete containment vessel for nuclear reactors is disclosed that is spherical and that has prestressing tendons disposed in first, second and third sets, the tendons of each set being all substantially concentric and centred around a respective one of the three orthogonal axes of the sphere; the tendons of the first set being anchored at each end at a first anchor rib running around a circumference of the vessel, the tendons of the second set being anchored at each end at a second anchor rib running around a circumference of the sphere and disposed at 90 0 to the first rib, and the tendons of the third set being anchored some to the first rib and the remainder to the second rib. (author)

  16. Angiogenesis and blood vessel stability in inflammatory arthritis.

    LENUS (Irish Health Repository)

    Kennedy, Aisling

    2012-02-01

    OBJECTIVE: To assess blood vessel stability in inflammatory synovial tissue (ST) and to examine neural cell adhesion molecule (NCAM), oxidative DNA damage, and hypoxia in vivo. METHODS: Macroscopic vascularity and ST oxygen levels were determined in vivo in patients with inflammatory arthritis who were undergoing arthroscopy. Vessel maturity\\/stability was quantified in matched ST samples by dual immunofluorescence staining for factor VIII (FVIII)\\/alpha-smooth muscle actin (alpha-SMA). NCAM and 8-oxo-7,8-dihydro-2\\'-deoxyguanosine (8-oxodG) were examined by immunohistochemistry. Angiogenesis was assessed in vitro, using human dermal endothelial cells (HDECs) in a Matrigel tube formation assay. RESULTS: A significant number of immature vessels (showing no pericyte recruitment) was observed in tissue from patients with inflammatory arthritis (P < 0.001), in contrast to osteoarthritic and normal tissue, which showed complete recruitment of pericytes. Low in vivo PO(2) levels in the inflamed joint (median [range] 22.8 [3.2-54.1] mm Hg) were inversely related to increased macroscopic vascularity (P < 0.04) and increased microscopic expression of FVIII and alpha-SMA (P < 0.04 and P < 0.03, respectively). A significant proportion of vessels showed focal expression of NCAM and strong nuclear 8-oxodG expression, implicating a loss of EC-pericyte contact and increased DNA damage, levels of which were inversely associated with low in vivo PO(2) (P = 0.04 for each comparison). Circulating cells were completely negative for 8-oxodG. Exposure of HDEC to 3% O(2) (reflecting mean ST in vivo measurements) significantly increased EC tube formation (P < 0.05). CONCLUSION: Our findings indicate the presence of unstable vessels in inflamed joints associated with hypoxia, incomplete EC-pericyte interactions, and increased DNA damage. These changes may further contribute to persistent hypoxia in the inflamed joint to further drive this unstable microenvironment.

  17. Gram staining with an automatic machine.

    Science.gov (United States)

    Felek, S; Arslan, A

    1999-01-01

    This study was undertaken to develop a new Gram-staining machine controlled by a micro-controller and to investigate the quality of slides that were stained in the machine. The machine was designed and produced by the authors. It uses standard 220 V AC. Staining, washing, and drying periods are controlled by a timer built in the micro-controller. A software was made that contains a certain algorithm and time intervals for the staining mode. One-hundred and forty smears were prepared from Escherichia coli, Staphylococcus aureus, Neisseria sp., blood culture, trypticase soy broth, direct pus and sputum smears for comparison studies. Half of the slides in each group were stained with the machine, the other half by hand and then examined by four different microbiologists. Machine-stained slides had a higher clarity and less debris than the hand-stained slides (p stained slides, some Gram-positive organisms showed poor Gram-positive staining features (p Gram staining with the automatic machine increases the staining quality and helps to decrease the work load in a busy diagnostic laboratory.

  18. An improved silver staining procedure for schizodeme analysis in polyacrylamide gradient gels

    Directory of Open Access Journals (Sweden)

    Antonio M. Gonçalves

    1990-03-01

    Full Text Available A simple protocol is described for the silver staining of polyacrylamide gradient gels used for the separation of restriction fragments of kinetoplast DNA [schizodeme analysis of trypanosomatids (Morel et al., 1980]. The method overcomes the problems of non-uniform staining and strong background color which are frequently encountered when conventional protocols for silver staining of linear gels. The method described has proven to be of general applicability for DNA, RNA and protein separations in gradient gels.

  19. A monoclonal antibody stains blastemal but not tubular components of Wilms' tumour

    NARCIS (Netherlands)

    Sarawar, S. R.; Schlingemann, R. O.; Kelsey, A.; Fleming, S.; Kumar, S.

    1988-01-01

    The monoclonal antibody PAL-E is specific for endothelial cells in a wide variety of normal and tumour tissue. In normal kidney, PAL-E reacts exclusively with the endothelium of non-glomerular blood vessels. In Wilms' tumour, binding of PAL-E was not restricted to the endothelium; staining of

  20. Sealing method and sealing device for radioactive waste containing vessel

    International Nuclear Information System (INIS)

    Ishiwatari, Koji; Otsuki, Akira

    1998-01-01

    A radioactive waste-containing body is hoisted down into a strong-material vessel opened upwardly, and a strong-material lid is hoisted down to the opening of the strong-material-vessel and welded. The strong material vessel is hoisted up and loaded on a corrosion resistant-material bottom plate placed horizontally. A corrosion resistant-material vessel having one opening end and having a corrosion resistant-material flange on the other end and previously agreed with the strong material-vessel main body is hoisted up by a hoisting device having an inserting device so that the opening of the corrosion resistant vessel is directed downwardly. The corrosion resistant vessel is press-fitted to the outside of the strong material-vessel by the inserting device while being heated by a preheater to shrink. Subsequently, the lower end of the corrosion resistant-material vessel and the corrosion resistant-material bottom plate are welded to constitute a corrosion resistant-material vessel. Then, the radioactive waste containing body can be sealed in a sealing vessel comprising the strong-material vessel and the corrosion resistant-material vessel. (N.H.)

  1. Laser treatment of Port-wine stains

    OpenAIRE

    Boffa, Michael J.

    2001-01-01

    A state-of-the-art pulsed dye laser machine to treat port-wine stains and other vascular lesions has been available in the Malta Health Service since 1999. This article reviews the pathophysiology and clinical features of port- wine stains and describes the principles of laser treatment for this condition.

  2. Vessel Operator System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Operator cards are required for any operator of a charter/party boat and or a commercial vessel (including carrier and processor vessels) issued a vessel permit from...

  3. Multicenter Assessment of Gram Stain Error Rates.

    Science.gov (United States)

    Samuel, Linoj P; Balada-Llasat, Joan-Miquel; Harrington, Amanda; Cavagnolo, Robert

    2016-06-01

    Gram stains remain the cornerstone of diagnostic testing in the microbiology laboratory for the guidance of empirical treatment prior to availability of culture results. Incorrectly interpreted Gram stains may adversely impact patient care, and yet there are no comprehensive studies that have evaluated the reliability of the technique and there are no established standards for performance. In this study, clinical microbiology laboratories at four major tertiary medical care centers evaluated Gram stain error rates across all nonblood specimen types by using standardized criteria. The study focused on several factors that primarily contribute to errors in the process, including poor specimen quality, smear preparation, and interpretation of the smears. The number of specimens during the evaluation period ranged from 976 to 1,864 specimens per site, and there were a total of 6,115 specimens. Gram stain results were discrepant from culture for 5% of all specimens. Fifty-eight percent of discrepant results were specimens with no organisms reported on Gram stain but significant growth on culture, while 42% of discrepant results had reported organisms on Gram stain that were not recovered in culture. Upon review of available slides, 24% (63/263) of discrepant results were due to reader error, which varied significantly based on site (9% to 45%). The Gram stain error rate also varied between sites, ranging from 0.4% to 2.7%. The data demonstrate a significant variability between laboratories in Gram stain performance and affirm the need for ongoing quality assessment by laboratories. Standardized monitoring of Gram stains is an essential quality control tool for laboratories and is necessary for the establishment of a quality benchmark across laboratories. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  4. Distribution of Vascular Patterns in Different Subtypes of Renal Cell Carcinoma. A Morphometric Study in Two Distinct Types of Blood Vessels.

    Science.gov (United States)

    Ruiz-Saurí, Amparo; García-Bustos, V; Granero, E; Cuesta, S; Sales, M A; Marcos, V; Llombart-Bosch, A

    2017-07-01

    To analyze the presence of mature and immature vessels as a prognostic factor in patients with renal cell carcinoma and propose a classification of renal cancer tumor blood vessels according to morphometric parameters. Tissue samples were obtained from 121 renal cell carcinoma patients who underwent radical nephrectomy. Staining with CD31 and CD34 was used to differentiate between immature (CD31+) and mature (CD34+) blood vessels. We quantified the microvascular density, microvascular area and different morphometric parameters: maximum diameter, minimum diameter, major axis, minor axis, perimeter, radius ratio and roundness. We found that the microvascular density was higher in CD31+ than CD34+ vessels, but CD34+ vessels were larger than CD31+ vessels, as well as being strongly correlated with the ISUP tumor grade. We also identified four vascular patterns: pseudoacinar, fascicular, reticular and diffuse. Pseudoacinar and fascicular patterns were more frequent in clear cell renal cell carcinoma (37.62 and 35.64% respectively), followed by reticular pattern (21.78%), while in chromophobe tumors the reticular pattern predominated (90%). The isolated pattern was present in all papillary tumors (100%). In healthy renal tissue, the pseudoacinar and isolated patterns were differentially found in the renal cortex and medulla respectively. We defined four distinct vascular patterns significantly related with the ISUP tumor grade in renal cell carcinomas. Further studies in larger series are needed in order to validate these results. Analysis of both mature and immature vessels (CD34+ and CD31+) provides additional information when evaluating microvascular density.

  5. <strong>Mini-project>

    DEFF Research Database (Denmark)

    Katajainen, Jyrki

    2008-01-01

    In this project the goal is to develop the safe * family of containers for the CPH STL. The containers to be developed should be safer and more reliable than any of the existing implementations. A special focus should be put on strong exception safety since none of the existing prototypes available...

  6. Correlation of FMISO simulations with pimonidazole-stained tumor xenografts: A question of O{sub 2} consumption?

    Energy Technology Data Exchange (ETDEWEB)

    Wack, L. J., E-mail: linda-jacqueline.wack@med.uni-tuebingen.de; Thorwarth, D. [Section for Biomedical Physics, Department of Radiation Oncology, University Hospital Tübingen, Tübingen 72076 (Germany); Mönnich, D. [Section for Biomedical Physics, Department of Radiation Oncology, University Hospital Tübingen, Tübingen 72076 (Germany); German Cancer Consortium (DKTK), Tübingen 72076 (Germany); German Cancer Research Center (DKFZ), Heidelberg 69121 (Germany); Yaromina, A. [OncoRay—National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden 01309, Germany and Department of Radiation Oncology (MAASTRO), GROW—School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht 6229 ET (Netherlands); Zips, D. [German Cancer Consortium (DKTK), Tübingen 72076 (Germany); German Cancer Research Center (DKFZ), Heidelberg 69121 (Germany); Department of Radiation Oncology, University Hospital Tübingen, Tübingen 72076 (Germany); and others

    2016-07-15

    Purpose: To compare a dedicated simulation model for hypoxia PET against tumor microsections stained for different parameters of the tumor microenvironment. The model can readily be adapted to a variety of conditions, such as different human head and neck squamous cell carcinoma (HNSCC) xenograft tumors. Methods: Nine different HNSCC tumor models were transplanted subcutaneously into nude mice. Tumors were excised and immunoflourescently labeled with pimonidazole, Hoechst 33342, and CD31, providing information on hypoxia, perfusion, and vessel distribution, respectively. Hoechst and CD31 images were used to generate maps of perfused blood vessels on which tissue oxygenation and the accumulation of the hypoxia tracer FMISO were mathematically simulated. The model includes a Michaelis–Menten relation to describe the oxygen consumption inside tissue. The maximum oxygen consumption rate M{sub 0} was chosen as the parameter for a tumor-specific optimization as it strongly influences tracer distribution. M{sub 0} was optimized on each tumor slice to reach optimum correlations between FMISO concentration 4 h postinjection and pimonidazole staining intensity. Results: After optimization, high pixel-based correlations up to R{sup 2} = 0.85 were found for individual tissue sections. Experimental pimonidazole images and FMISO simulations showed good visual agreement, confirming the validity of the approach. Median correlations per tumor model varied significantly (p < 0.05), with R{sup 2} ranging from 0.20 to 0.54. The optimum maximum oxygen consumption rate M{sub 0} differed significantly (p < 0.05) between tumor models, ranging from 2.4 to 5.2 mm Hg/s. Conclusions: It is feasible to simulate FMISO distributions that match the pimonidazole retention patterns observed in vivo. Good agreement was obtained for multiple tumor models by optimizing the oxygen consumption rate, M{sub 0}, whose optimum value differed significantly between tumor models.

  7. Surface staining of small intestinal biopsies

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1977-01-01

    Small intestinal biopsies are most often by routine examined under a stereo-microscope, prior to embedding for histological examination. This is done in order to get a view of the appearance of the mucosal pattern, especially villus configuration. The distinctness of the surface pattern however......, is improved considerably if the biopsies are stained with Alcian Green and/or PAS before they are examined. In the present paper a detailed description is given of staining of small intestinal biopsies as whole mounts. The difference between the unstained and the stained biopsies is illustrated by a few...

  8. Strong interactions

    International Nuclear Information System (INIS)

    Froissart, Marcel

    1976-01-01

    Strong interactions are introduced by their more obvious aspect: nuclear forces. In hadron family, the nucleon octet, OMEGA - decuplet, and quark triply are successively considered. Pion wave having been put at the origin of nuclear forces, low energy phenomena are described, the force being explained as an exchange of structure corresponding to a Regge trajectory in a variable rotating state instead of the exchange of a well defined particle. At high energies the concepts of pomeron, parton and stratons are introduced, pionization and fragmentation are briefly differentiated [fr

  9. Comparison of special stains for keratin with routine hematoxylin and eosin stain.

    Science.gov (United States)

    Rao, Roopa S; Patil, Shankargouda; Majumdar, Barnali; Oswal, Rakesh G

    2015-03-01

    Keratins are the most abundant proteins and are characteristic findings in many epithelial pathologies, making it a diagnostically important marker, both histopathologically and immunohistochemically. Since, immunohistochemistry is an expensive diagnostic tool, special stains to detect the degree of keratinization could serve as a faster and economic option. The aim of the present study was to compare the efficacy of special stains for keratin with standard hematoxylin and eosin stain (H and E). Objectives include: (i) To subject the diagnosed cases of keratin disorders to the selected special stains: Ayoub-shklar method, Dane-Herman method, Alcian blue -periodic acid Schiff 's (PAS), rapid papanicolaou (PAP) and Gram's stain. (ii) To compare the staining specificity and staining intensity of special stains with respect to routine hematoxylin and eosin (H and E) stain. (iii) To compare the efficacy of special stains to routine H and E stain in identification of the type of keratin present in the selected cases. A total of 80 cases of known pathology for keratin were retrieved from the department archive, which included 10 each of normal gingiva, hyperkeratosis, squamous papilloma, verrucous hyperplasia, verrucous carcinoma, well-differentiated squamous cell carcinoma, orthokeratinized odontogenic cyst and keratocystic odontogenic tumors. Six sections of 4 µ each from the paraffin blocks were made, stained with H and E and the special stains and these were evaluated by 2 pathologists based on the modified scoring criteria from Rahma Al-Maaini and Philip Bryant 2008. The results were tabulated using Chi square and kappa statistics. The statistical values for identification of the type of keratinization was insignificant showing that ortho and parakeratinized epithelia could be correctly identified by both H and E as well as all the special stains. Furthermore, all the special stains showed a positive result and statistical significance (P < 0.001) with respect to

  10. Gram staining apparatus for space station applications

    Science.gov (United States)

    Molina, T. C.; Brown, H. D.; Irbe, R. M.; Pierson, D. L.

    1990-01-01

    A self-contained, portable Gram staining apparatus (GSA) has been developed for use in the microgravity environment on board the Space Station Freedom. Accuracy and reproducibility of this apparatus compared with the conventional Gram staining method were evaluated by using gram-negative and gram-positive controls and different species of bacteria grown in pure cultures. A subsequent study was designed to assess the performance of the GSA with actual specimens. A set of 60 human and environmental specimens was evaluated with the GSA and the conventional Gram staining procedure. Data obtained from these studies indicated that the GSA will provide the Gram staining capability needed for the microgravity environment of space.

  11. Research on pre-staining gel electrophoresis

    International Nuclear Information System (INIS)

    Zhong Ruibo; Liu Yushuang; Zhang Ping; Liu Jingran; Zhao Guofen; Zhang Feng

    2014-01-01

    Background: Gel electrophoresis is a powerful biochemical separation technique. Most biological molecules are completely transparent in the visible region of light, so it is necessary to use staining to show the results after gel electrophoresis, and the general steps of conventional staining methods are time-consuming. Purpose: We try to develop a novel approach to simplify the gel electrophoresis: Pre-Staining Gel Electrophoresis (PSGE), which can make the gel electrophoresis results monitored in real time. Methods: Pre-stain the protein samples with Coomassie Brilliant Blue (CBB) for 30 min before loading the sample into the gel well. Results and Conclusion: PSGE can be successfully used to analyze the binding efficiency of Bovine Serum Albumin (BSA) and amphiphilic polymer via chemical coupling and physical absorption, and the double PSGE also shows a great potential in bio-analytical chemistry. (authors)

  12. Effectiveness of Vascular Markers (Immunohistochemical Stains) in Soft Tissue Sarcomas.

    Science.gov (United States)

    Naeem, Namra; Mushtaq, Sajid; Akhter, Noreen; Hussain, Mudassar; Hassan, Usman

    2018-05-01

    To ascertain the effectiveness of IHC markers of vascular origin like CD31, CD34, FLI1 and ERG in vascular soft tissue sarcomas including angiosarcomas, Kaposi sarcomas, epithelioid hemangioendothelioma and a non-vascular soft tissue sarcoma (Epithelioid sarcoma). Descriptive study. Shaukat Khanum Memorial Cancer Hospital and Research Centre, Lahore, from 2011 to 2017. Diagnosed cases of angiosarcomas (n=48), epithelioid hemangioendothelioma (n=9), Kaposi sarcoma (n=9) and epithelioid sarcoma (n=20) were selected. Immunohistochemical staining as performed on formalin fixed paraffin embedded sections. The sections were stained for the following markers: CD34 (VENTANA clone Q Bend 10), CD31 (Leica clone 1 A 10), FLI1 (CELL MARQUE clone MRQ-1) and ERG (CELL MARQUE clone EP111). A complete panel of CD34, CD31 and ERG was applied on 8/48 cases of angiosarcomas with triple positivity in 6 cases. Eight cases showed positivity for only CD31 and ERG and 2 cases showed positivity for only ERG. A complete panel of CD34, CD31 and ERG was applied on 3/9 cases of epithelioid hemangioendothelioma with positivity for all markers in 2 cases. Combined positivity for ERG and CD34 was seen in 2 cases and on 4 cases only CD31 immunohistochemical was solely applied with 100% positivity. FLI1 was not applied on any case. Among 9 cases of Kaposi sarcoma, ERG, CD34 and CD31 in combination were applied on only 1 case with triple positivity. Remaining cases show positivity for either CD34, CD31 or FLI1. Majority of cases of epithelioid sarcomas were diagnosed on the basis of cytokeratin and CD34 positivity with loss of INI1. The other vascular markers showed negativity in all cases. Among these four markers, ERG immunohistochemical stain is highly effective for endothelial differentiation due to its specific nuclear staining pattern in normal blood vessel endothelial cells (internal control) as well as neoplastic cells of vascular tumors and lack of background staining.

  13. New Grocott Stain without Using Chromic Acid

    International Nuclear Information System (INIS)

    Shiogama, Kazuya; Kitazawa, Kayo; Mizutani, Yasuyoshi; Onouchi, Takanori; Inada, Ken-ichi; Tsutsumi, Yutaka

    2015-01-01

    We established a new “ecological” Grocott stain for demonstrating fungi, based upon a 4R principle of refusal, reduction, reuse, and recycle of waste management. Conventional Grocott stain employs environmentally harsh 5% chromic acid for oxidization. Initially, we succeeded in reducing the concentration of chromic acid from 5% to 1% by incubating the solution at 60°C and using five-fold diluted chromic acid solution at which point it was reusable. Eventually, we reached the refusal level where 1% periodic acid oxidization was efficient enough, when combined with preheating of sections in the electric jar, microwave oven, or pressure pan. For convenience sake, we recommend pressure pan heating in tap water for 10 min. Stainability of fungi in candidiasis and aspergillosis was comparable with conventional Grocott stain, while Mucor hyphae showed enhanced staining. The modified sequence was further applicable to detecting a variety of mycotic pathogens in paraffin sections. Our environmentally-friendly Grocott stain also has the advantage of avoiding risk of human exposure to hexavalent chromium solution in the histopathology laboratory. The simple stain sequence is can be easily applied worldwide

  14. TEM validation of immunohistochemical staining prior to assessment of tumour angiogenesis by computerised image analysis

    International Nuclear Information System (INIS)

    Killingsworth, M.C.

    2002-01-01

    Full text: Counts of microvessel density (MVD) within solid tumours have been shown to be an independent predictor of outcome with higher counts generally associated with a worse prognosis. These assessments are commonly performed on immunoperoxidase stained (IPX) sections with antibodies to CD34, CD31 and Factor VIII-related antigen routinely used as vascular markers. Tumour vascular density is thought to reflect the demand the growing neoplasm is placing on its feeding blood supply. Vascular density also appears to be associated with spread of invasive cells to distant sites. The present study of tumour angiogenesis in prostate cancer specimens aims to assess new vessel growth in addition to MVD counts. The hypothesis being that an assessment which takes into account vascular migration and proliferation as well as the number of patent vessels present may have improved predictive power over assessments based on MVD counts alone. We are employing anti-CD34 stained IPX sections which are digitally photographed and assessed by a computerised image analysis system. Our aim is to develop parameters whereby tumour angiogenesis may be assessed at the light microscopic level and then correlated with existing histological methods of tumour assessment such as Gleason grading. In order to use IPX stained sections for angiogenic assessment validation and understanding of the anti-CD34 immunostaining pattern was necessary. This involved the following steps: i) Morphological assessment of angiogenic changes present in tumour blood vessels. Morphological changes in endothelial cells and pericytes indicative of angiogenic activation are generally below the level of resolution available with light microscopy. TEM examination revealed endothelial cell budding, pericyte retraction, basement membrane duplication and endothelial sprout formation in capillaries and venules surrounding tumour glands. This information assisted with the development of parameters by which IPX sections

  15. The Luna stain, an improved selective stain for detection of microsporidian spores in histologic sections

    Science.gov (United States)

    Peterson, Tracy S.; Spitsbergen, Jan M.; Feist, Stephen W.; Kent, Michael L.

    2014-01-01

    Microsporidia in histologic sections are most often diagnosed by observing spores in host tissues. Spores are easy to identify if they occur in large aggregates or xenomas when sections are stained with hematoxylin and eosin (H&E). However, individual spores are not frequently detected in host tissues with conventional H&E staining, particularly if spores are scattered within the tissues, areas of inflammation or small spores in nuclei (i.e., Nucleospora salmonis). Hence, a variety of selective stains that enhance visualization of spores are recommended. We discovered that the Luna stain, used to highlight eosinophils, red blood cells and chitin in arthropods and other invertebrates, also stains spores of Pseudoloma neurophilia. We compared this stain to the Gram, Fite’s acid fast, Giemsa, and H&E stains on eight aquatic microsporidian organisms that were readily available in our two laboratories: Loma salmonae, Glugea anomala, Pseudoloma neurophilia, Pleistophora hyphessobryconis, Pleistophora vermiformis, Glugea sp., Steinhausia mytilovum and an unidentified microsporidian from E. sinensis, UK. Based on tinctorial properties and background staining, the Luna stain performed better for detection of 6 of the 8 microsporidia. Gram stain was superior for the two microsporidia from invertebrates, Steinhausia mytilovum and the unidentified microsporidian from E. sinensis. PMID:21848126

  16. Nuclear reactor pressure vessel flaw distribution development

    International Nuclear Information System (INIS)

    Kennedy, E.L.; Foulds, J.R.; Basin, S.L.

    1991-12-01

    Previous attempts to develop flaw distributions for probabilistic fracture mechanics analyses of pressurized water reactor (PWR) vessels have aimed at the estimation of a ''generic'' distribution applicable to all PWR vessels. In contrast, this report describes (1) a new flaw distribution development analytic methodology that can be applied to the analysis of vessel-specific inservice inspection (ISI) data, and (2) results of the application of the methodology to the analysis of flaw data for each vessel case (ISI data on three PWR vessels and laboratory inspection data on sections of the Midland reactor vessel). Results of this study show significant variation among the flaw distributions derived from the various data sets analyzed, strongly suggesting than a vessel-specific flaw distribution (for vessel integrity prediction under pressurized thermal shock) is preferred over a ''generic'' distribution. In addition, quantitative inspection system flaw sizing accuracy requirements have been identified for developing a flaw distribution from vessel ISI data. The new flaw data analysis methodology also permits quantifying the reliability of the flaw distribution estimate. Included in the report are identified needs for further development of several aspects of ISI data acquisition and vessel integrity prediction practice

  17. The clinical impact of mean vessel size and solidity in breast carcinoma patients.

    Directory of Open Access Journals (Sweden)

    Lars Tore Gyland Mikalsen

    Full Text Available Angiogenesis quantification, through vessel counting or area estimation in the most vascular part of the tumour, has been found to be of prognostic value across a range of carcinomas, breast cancer included. We have applied computer image analysis to quantify vascular properties pertaining to size, shape and spatial distributions in photographed fields of CD34 stained sections. Aided by a pilot (98 cases, seven parameters were selected and validated on a separate set from 293 breast cancer patients. Two new prognostic markers were identified through continuous cox regression with endpoints breast cancer specific survival and distant disease free survival: The average size of the vessels as measured by their perimeter (p = 0.003 and 0.004, respectively, and the average complexity of the vessel shapes measured by their solidity (p = 0.004 and 0.004. The Hazard ratios for the corresponding median-dichotomized markers were 2.28 (p = 0.005 and 1.89 (p = 0.016 for the mean perimeter and 1.80 (p = 0.041 and 1.55 (p = 0.095 for the shape complexity. The markers were associated with poor histologic type, high grade, necrosis, HR negativity, inflammation, and p53 expression (vessel size only. Both markers were found to strongly influence the prognostic properties of vascular invasion (VI and disseminated tumour cells in the bone marrow. The latter being prognostic only in cases with large vessels (p = 0.004 and 0.043 or low complexity (p = 0.018 and 0.024, but not in the small or complex vessel groups (p>0.47. VI was significant in all groups, but showed greater hazard ratios for small and low complexity vessels (6.54-11.2 versus large and high complexity vessels (2.64-3.06. We find that not only the overall amount of produced vasculature in angiogenic hot-spots is of prognostic significance, but also the morphological appearance of the generated vessels, i.e. the size and shape of vessels in the studied hot spots.

  18. Propidium iodide (PI) stains Nissl bodies and may serve as a quick marker for total neuronal cell count.

    Science.gov (United States)

    Niu, Junfei; Li, Chunman; Wu, Haihui; Feng, Xianling; Su, Qingning; Li, Shihe; Zhang, Lihong; Yew, David Tai Wai; Cho, Eric Yu Pang; Sha, Ou

    2015-03-01

    Propidium iodide (PI) reacts with both DNA and RNA and is a commonly used fluorescent reagent for nucleic acid staining. The aim of the study was to compare the cellular staining patterns of PI with that of Nissl staining in rat nervous tissues and to report a modified staining method that selectively labels Nissl bodies in neurons. Cryosections and paraffin sections of different tissues of normal Sprague-Dawley rats, including trigeminal ganglia, dorsal root ganglia, spinal cord, liver, and small intestine, were stained by either PI or the hematoxylin and eosin method. Some sections were treated with RNase or DNase before the above staining, and some were double stained with PI and a Nissl stain. The sections were observed by light, fluorescence or confocal microscopy. Results showed strong PI signals detected as patterns of granules in the neuronal cytoplasm of all nervous tissues, whereas the staining of neuronal nuclei was weaker. In contrast, nuclei of neuroglial cells were strongly stained by PI, while the cytoplasm was not obviously stained. Pretreatment of the neural tissue with RNase abolished the PI signals. Furthermore, the PI positive granules in neuronal cytoplasm co-localized with Nissl bodies stained by the fluorescent Nissl stain. When the tissue was pretreated with DNase, PI only stained the cytoplasmic granules of neurons, but not that of glial cells. Our results show that PI stains Nissl bodies and may serve as an economical and convenient neuron marker for neuronal cell counting when specific neural markers such as antibodies are not readily available. Copyright © 2015. Published by Elsevier GmbH.

  19. Selection and application of exterior stains for wood

    Science.gov (United States)

    R. Sam. Williams; William C. Feist

    1999-01-01

    Exterior stains for wood protect the wood surface from sunlight and moisture. Because stains are formulated to penetrate the wood surface, they are not prone to crack or peel as can film-forming finishes, such as paints. This publication describes the properties of stains and wood, methods for applying stains, and the expected service life of stains.

  20. Multiple shell pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.

    1988-01-01

    A method is described of fabricating a pressure vessel comprising the steps of: attaching a first inner pressure vessel having means defining inlet and outlet openings to a top flange, placing a second inner pressure vessel, having means defining inlet and outlet opening, concentric with and spaced about the first inner pressure vessel and attaching the second inner pressure vessel to the top flange, placing an outer pressure vessel, having inlet and outlet openings, concentric with and spaced apart about the second inner pressure vessel and attaching the outer pressure vessel to the top flange, attaching a generally cylindrical inner inlet conduit and a generally cylindrical inner outlet conduit respectively to the inlet and outlet openings in the first inner pressure vessel, attaching a generally cylindrical outer inlet conduit and a generally cylindrical outer outlet conduit respectively to the inlet and outlet opening in the second inner pressure vessel, heating the assembled pressure vessel to a temperature above the melting point of a material selected from the group, lead, tin, antimony, bismuth, potassium, sodium, boron and mixtures thereof, filling the space between the first inner pressure vessel and the second inner pressure vessel with material selected from the group, filling the space between the second inner pressure vessel and the outer pressure vessel with material selected from the group, and pressurizing the material filling the spaces between the pressure vessels to a predetermined pressure, the step comprising: pressurizing the spaces to a pressure whereby the wall of the first inner pressure vessel is maintained in compression during steady state operation of the pressure vessel

  1. Cell wall staining with Trypan blue enables quantitative analysis of morphological changes in yeast cells

    DEFF Research Database (Denmark)

    Liesche, Johannes; Marek, Magdalena; Günther-Pomorski, Thomas

    2015-01-01

    staining with fluorescent dyes is a valuable tool. Furthermore, cell wall staining is used to facilitate sub-cellular localization experiments with fluorescently-labeled proteins and the detection of yeast cells in non-fungal host tissues. Here, we report staining of Saccharomyces cerevisiae cell wall......Yeast cells are protected by a cell wall that plays an important role in the exchange of substances with the environment. The cell wall structure is dynamic and can adapt to different physiological states or environmental conditions. For the investigation of morphological changes, selective...... with Trypan Blue, which emits strong red fluorescence upon binding to chitin and yeast glucan; thereby, it facilitates cell wall analysis by confocal and super-resolution microscopy. The staining pattern of Trypan Blue was similar to that of the widely used UV-excitable, blue fluorescent cell wall stain...

  2. Staining of proteins in gels with Coomassie G-250 without organic solvent and acetic acid.

    Science.gov (United States)

    Lawrence, Ann-Marie; Besir, H Uuml Seyin

    2009-08-14

    In classical protein staining protocols using Coomassie Brilliant Blue (CBB), solutions with high contents of toxic and flammable organic solvents (Methanol, Ethanol or 2-Propanol) and acetic acid are used for fixation, staining and destaining of proteins in a gel after SDS-PAGE. To speed up the procedure, heating the staining solution in the microwave oven for a short time is frequently used. This usually results in evaporation of toxic or hazardous Methanol, Ethanol or 2-Propanol and a strong smell of acetic acid in the lab which should be avoided due to safety considerations. In a protocol originally published in two patent applications by E.M. Wondrak (US2001046709 (A1), US6319720 (B1)), an alternative composition of the staining solution is described in which no organic solvent or acid is used. The CBB is dissolved in bidistilled water (60-80 mg of CBB G-250 per liter) and 35 mM HCl is added as the only other compound in the staining solution. The CBB staining of the gel is done after SDS-PAGE and thorough washing of the gel in bidistilled water. By heating the gel during the washing and staining steps, the process can be finished faster and no toxic or hazardous compounds are evaporating. The staining of proteins occurs already within 1 minute after heating the gel in staining solution and is fully developed after 15-30 min with a slightly blue background that is destained completely by prolonged washing of the stained gel in bidistilled water, without affecting the stained protein bands.

  3. Comparism of Various Staining Techniques in the Diagnosis of ...

    African Journals Online (AJOL)

    SITWALA COMPUTERS

    external intermediate host, usually an animal, in which sporogenesis and oocyst ... the parasite was detected in 111 of the samples stained,. 100(90.0%) of which .... screen stained slide was the auramine fluorochrome stain. The widely used ...

  4. Probabilistic retinal vessel segmentation

    Science.gov (United States)

    Wu, Chang-Hua; Agam, Gady

    2007-03-01

    Optic fundus assessment is widely used for diagnosing vascular and non-vascular pathology. Inspection of the retinal vasculature may reveal hypertension, diabetes, arteriosclerosis, cardiovascular disease and stroke. Due to various imaging conditions retinal images may be degraded. Consequently, the enhancement of such images and vessels in them is an important task with direct clinical applications. We propose a novel technique for vessel enhancement in retinal images that is capable of enhancing vessel junctions in addition to linear vessel segments. This is an extension of vessel filters we have previously developed for vessel enhancement in thoracic CT scans. The proposed approach is based on probabilistic models which can discern vessels and junctions. Evaluation shows the proposed filter is better than several known techniques and is comparable to the state of the art when evaluated on a standard dataset. A ridge-based vessel tracking process is applied on the enhanced image to demonstrate the effectiveness of the enhancement filter.

  5. Pleural and Pulmonary Staining at Inferior Phrenic Arteriography Mimicking a Tumor Staining of Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Lee, Deok Hee; Hwang, Jae Cheol; Lim, Soo Mee; Yoon, Hyun-Ki; Sung, Kyu-Bo; Song, Ho-Young

    2000-01-01

    Purpose: To describe the findings of pleural and pulmonary staining of the inferior phrenic artery, which can be confused with tumor staining during transarterial chemoembolization (TACE) of hepatoma.Methods: Fifteen patients who showed pleural and pulmonary staining without relationship to hepatic masses at inferior phrenic arteriography were enrolled. The staining was noted at initial TACE (n = 8), at successive TACE (n = 5), and after hepatic surgery (n = 2). The angiographic pattern, the presence of pleural change on computed tomography (CT), and clinical history were evaluated.Results: Draining pulmonary veins were seen in all cases. The lower margin of the staining corresponded to the lower margin of the pleura in 10 patients. CT showed pleural and/or pulmonary abnormalities in all cases. After embolization of the inferior phrenic artery, the accumulation of iodized oil in the lung was noted.Conclusion: Understanding the CT and angiographic findings of pleural and pulmonary staining during TACE may help differentiate benign staining from tumor staining

  6. Short Nissl staining for incubated cryostat sections of the brain.

    Science.gov (United States)

    Lindroos, O F

    1991-01-01

    Nissl stain often binds poorly to cryostat sections which have been incubated in solutions of radiolabeled ligands. Such incubation is used in receptor autoradiography of the brain when using the in vitro method. We have developed a rapid (16 min) modification of Nissl staining for sections that bind stain poorly, e.g., incubated sections. The method stains well sections which cannot be stained with other rapid Nissl staining methods.

  7. Improvement to reactor vessel

    International Nuclear Information System (INIS)

    1974-01-01

    The vessel described includes a prestressed concrete vessel containing a chamber and a removable cover closing this chamber. The cover is in concrete and is kept in its closed position by main and auxiliary retainers, comprising fittings integral with the concrete of the vessel. The auxiliary retainers pass through the concrete of the cover. This improvement may be applied to BWR, PWR and LMFBR type reactor vessel [fr

  8. ALICE HMPID Radiator Vessel

    CERN Document Server

    2003-01-01

    View of the radiator vessels of the ALICE/HMPID mounted on the support frame. Each HMPID module is equipped with 3 indipendent radiator vessels made out of neoceram and fused silica (quartz) windows glued together. The spacers inside the vessel are needed to stand the hydrostatic pressure. http://alice-hmpid.web.cern.ch/alice-hmpid

  9. A comparative assessment of commonly employed staining ...

    African Journals Online (AJOL)

    Following an increase in the number of reports of Cryptosporidium infections and the problems encountered in detecting these organisms in faecal smears, a comparative assessment of a modification of the Sheather's flotation technique and other commonly employed staining procedures proved the modified Sheather's ...

  10. Photoacoustic imaging of port-wine stains

    NARCIS (Netherlands)

    Kolkman, Roy G. M.; Mulder, Miranda J.; Glade, Conrad P.; Steenbergen, Wiendelt; van Leeuwen, Ton G.

    2008-01-01

    BACKGROUND AND OBJECTIVE: To optimize laser therapy of port-wine stains (PWSs), information about the vasculature as well as lesion depth is valuable. In this study we investigated the use of photoacoustic imaging (PAI) to obtain this information. STUDY DESIGN/MATERIALS AND METHODS: PAI uses pulsed

  11. Photoacoustic Imaging of Port-Wine Stains

    NARCIS (Netherlands)

    Kolkman, R.G.M.; Mulder, M.J.; Mulder, Miranda J.; Glade, Conrad P.; Steenbergen, Wiendelt; van Leeuwen, Ton

    2008-01-01

    Background and Objective: To optimize laser therapy of port-wine stains (PWSs), information about the vasculature as well as lesion depth is valuable. In this study we investigated the use of photoacoustic imaging (PAI) to obtain this information. - Study Design/Materials and Methods: PAI uses

  12. The effect of corrosion on stained glass windows

    Directory of Open Access Journals (Sweden)

    Laissner, Johanna

    1996-06-01

    Full Text Available Stained glass windows belong to the most important cultural heritage of Europe. Within the last decades a disastrous deterioration took place. The wonderful stained glass windows and their glass paintings as pieces of art are acutely menaced by environmental corrosive influences. This corrosion process is a very complex reaction which is not only influenced by temperature and humidity changes but also by gaseous pollutants like sulfur dioxide, nitrogen oxides or ozone, by dust and air, microorganisms as well as synergetic interactions. Strongly affected by these environmental attacks are medieval stained glasses due to their chemical composition. They have a low content in silica and high contents of modifier ions (e.g. potassium and calcium. The corrosion phenomena can range from predominantly pitting on the surface to the formation of thick corrosion crusts which are turning the panel opaque and thus reducing strongly the transparency of the windows. In order to set up a conservation and restoration concept, it is necessary to know about the environmental conditions to which the stained glass windows are exposed. For this purpose very corrosion sensitive model glasses (so called glass sensors were developed which have a similar chemical composition as historic stained glasses. They exhibit the same corrosion reactions but react much faster, and are now widely used to estimate corrosive stresses on stained glass windows to give basic information about the corrosive impacts which work on the historic glasses. In this paper principle corrosion mechanisms of stained glass windows and their enhancing factors are discussed. For the evaluation of the environmental impact, the application of glass sensors is demonstrated.

    Las vidrieras coloreadas pertenecen al legado cultural más importante de Europa. En las últimas décadas se ha producido en ellas un desastroso deterioro. Las maravillosas vidrieras coloreadas y sus policromías est

  13. Staining for factor VIII related antigen and Ulex europaeus agglutinin I (UEA-I) in 230 tumours. An assessment of their specificity for angiosarcoma and Kaposi's sarcoma.

    Science.gov (United States)

    Leader, M; Collins, M; Patel, J; Henry, K

    1986-11-01

    In this study we examined the staining reactivity of commercially available antisera to factor VIII related antigen (F VIII RAg) and Ulex europaeus agglutinin I (UEA-I) on sections from 230 formalin fixed paraffin embedded tumours. These included 196 sarcomas, 20 carcinomas and 14 angiomas. All angiomas showed positive staining for F VIII RAg; all carcinomas showed negative staining; the vasoformative areas of all angiosarcomas stained positively but only four of six angiosarcomas showed positive staining of their solid areas; of seven Kaposi's sarcomas, all showed positive staining of vessels and six showed positive staining of the spindle cell component. In the remaining 181 non-vascular sarcomas there was a false positive result in four tumours (2.2%), three of which had a history of irradiation. Pre-radiotherapy biopsies of these three tumours stained negatively with anti-F VIII RAg. UEA-I was demonstrated in all the angiomas studied, in all angiosarcomas (including the solid components) and in well-formed vessels of all Kaposi's sarcomas, but only in the spindle cell component of 3/6. However, there was an unacceptably high rate of false positive staining amongst the carcinomas and non-vascular sarcomas. In conclusion, F VIII RAg is a specific but not a sensitive marker of angiosarcomas; UEA-I is a sensitive but not a specific marker of angiosarcomas.

  14. Structural analysis of the KSTAR vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    In, Sang Ryul; Yoon, Byeong Joo [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-10-01

    Structure analysis of the vacuum vessel for the KSTAR tokamak which, is in the end phase of the conceptual design have been performed. Mechanical stresses and deformations of the vessel produced by constant forces due to atmospheric pressure, dead weight, fluid pressure, etc and various transient electromagnetic forces induced during tokamak operations were calculated as well as modal characteristics and buckling properties were investigated. Influences of the temperature gradient and the constraint condition of the support on the thermal stress and deformation of the vessel were analyzed. The thermal stress due to the temperature distribution on the vessel as supplying the N{sub 2} gas of 400 deg C through poloidal channels according to the recent baking concept were calculated. No severe problem in the robustness of the vessel was found when applying the constant pressures on the vessel. However the mechanical stress due to the EM force induced by halo currents flowing on the vessel and the plasma facing components (PFCs) far exceeded the allowable limit. Some reinforcing components should be added on the boundary of the PFC support and the vessel, and that of the vessel support and the vessel. A steep temperature gradient in the vicinity of the inlet and oulet of the heating gas produced a thermal stress much higher than allowable. It is necessary to make the temperature of the vessel as uniform as possible and to develop a new support concept which is flexible enough to accommodate a thermal expansion of a few cm while sufficiently strong to resist mechanical impacts. (author). 5 refs., 41 figs., 9 tabs.

  15. Laser Treatment of Port Wine Stains

    Science.gov (United States)

    Majaron, Boris; Nelson, J. Stuart

    Port wine stain (PWS), also called nevus flammeus, is a congenital, cutaneous vascular malformation involving post-capillary venules which produce a light pink to red to dark-red-violet discoloration of human skin [1]. PWS occurs in an estimated 3 children per 1000 live births, affecting males and females and all racial groups equally [2]. There appears to be no hereditary predilection for PWS within families. There are no known risk factors or ways to prevent PWS.

  16. Stain Deconvolution Using Statistical Analysis of Multi-Resolution Stain Colour Representation.

    Directory of Open Access Journals (Sweden)

    Najah Alsubaie

    Full Text Available Stain colour estimation is a prominent factor of the analysis pipeline in most of histology image processing algorithms. Providing a reliable and efficient stain colour deconvolution approach is fundamental for robust algorithm. In this paper, we propose a novel method for stain colour deconvolution of histology images. This approach statistically analyses the multi-resolutional representation of the image to separate the independent observations out of the correlated ones. We then estimate the stain mixing matrix using filtered uncorrelated data. We conducted an extensive set of experiments to compare the proposed method to the recent state of the art methods and demonstrate the robustness of this approach using three different datasets of scanned slides, prepared in different labs using different scanners.

  17. Investigation of black soot staining in houses

    Energy Technology Data Exchange (ETDEWEB)

    Fugler, D. [Canada Mortgage and Housing Corp., Ottawa, ON (Canada)

    2000-07-01

    Air quality investigators are frequently called upon to determine the origin of streaking, staining or soot marks in both new and old homes. Those marks display common characteristics: black marks along baseboards at interior or exterior walls, behind furniture and at doorways; black smudges on window frames and plastic cabinets; and even shadowing of studs on exterior wall drywall in a few cases. In most instances, carbon soot from a combustion source is the culprit. The combustion sources include furnaces, water heaters, fireplaces, gas dryers, gas ranges, smoking, vehicle exhaust and candle burning. Scepticism about candle soot is prevalent among callers. As a result, a study was initiated in homes where occupants burn candles regularly to investigate soot problems. Samples were collected from five homes, and included stained carpets, filters, and swab samples of black dust or soot. All the houses selected for the study had been built within a three-year period. Some samples of candles commonly burned in those homes were burnt in a laboratory. Air quality audits had been performed in the homes and had revealed other potential pollutant sources. Best practices for cost-effective clean up and control of soot were researched in industry information. The tests conducted in the laboratory found materials consistent with candle soot or residue during microscopic investigations, but no link was established with the stained material obtained from the homes. A few tips for homeowners were included concerning candle burning, and tips for builders were also offered. 1 tab.

  18. Follicular thyroid carcinoma invades venous rather than lymphatic vessels

    Directory of Open Access Journals (Sweden)

    Liu Yulin

    2010-01-01

    Full Text Available Abstract Follicular thyroid carcinoma (FTC tends to metastasize to remote organs rather than local lymph nodes. Separation of FTC from follicular thyroid adenoma (FTA relies on detection of vascular and/or capsular invasion. We investigated which vascular markers, CD31, CD34 and D2-40 (lymphatic vessel marker, can best evaluate vascular invasion and why FTC tends to metastasize via blood stream to remote organs. Thirty two FTCs and 34 FTAs were retrieved for evaluation. The average age of patients with FTA was 8 years younger than FTC (p = 0.02. The female to male ratio for follicular neoplasm was 25:8. The average size of FTC was larger than FTA (p = 0.003. Fourteen of 32 (44% FTCs showed venous invasion and none showed lymphatic invasion, with positive CD31 and CD34 staining and negative D2-40 staining of the involved vessels. The average number of involved vessels was 0.88 ± 1.29 with a range from 0 to 5, and the average diameter of involved vessels was 0.068 ± 0.027 mm. None of the 34 FTAs showed vascular invasion. CD31 staining demonstrated more specific staining of vascular endothelial cells than CD34, with less background staining. We recommended using CD31 rather than CD34 and/or D2-40 in confirming/excluding vascular invasion in difficult cases. All identified FTCs with vascular invasions showed involvement of venous channels, rather than lymphatic spaces, suggesting that FTCs prefer to metastasize via veins to distant organs, instead of lymphatic vessels to local lymph nodes, which correlates with previous clinical observations.

  19. Pressure vessel design manual

    CERN Document Server

    Moss, Dennis R

    2013-01-01

    Pressure vessels are closed containers designed to hold gases or liquids at a pressure substantially different from the ambient pressure. They have a variety of applications in industry, including in oil refineries, nuclear reactors, vehicle airbrake reservoirs, and more. The pressure differential with such vessels is dangerous, and due to the risk of accident and fatality around their use, the design, manufacture, operation and inspection of pressure vessels is regulated by engineering authorities and guided by legal codes and standards. Pressure Vessel Design Manual is a solutions-focused guide to the many problems and technical challenges involved in the design of pressure vessels to match stringent standards and codes. It brings together otherwise scattered information and explanations into one easy-to-use resource to minimize research and take readers from problem to solution in the most direct manner possible. * Covers almost all problems that a working pressure vessel designer can expect to face, with ...

  20. Tumor Blood Vessel Dynamics

    Science.gov (United States)

    Munn, Lance

    2009-11-01

    ``Normalization'' of tumor blood vessels has shown promise to improve the efficacy of chemotherapeutics. In theory, anti-angiogenic drugs targeting endothelial VEGF signaling can improve vessel network structure and function, enhancing the transport of subsequent cytotoxic drugs to cancer cells. In practice, the effects are unpredictable, with varying levels of success. The predominant effects of anti-VEGF therapies are decreased vessel leakiness (hydraulic conductivity), decreased vessel diameters and pruning of the immature vessel network. It is thought that each of these can influence perfusion of the vessel network, inducing flow in regions that were previously sluggish or stagnant. Unfortunately, when anti-VEGF therapies affect vessel structure and function, the changes are dynamic and overlapping in time, and it has been difficult to identify a consistent and predictable normalization ``window'' during which perfusion and subsequent drug delivery is optimal. This is largely due to the non-linearity in the system, and the inability to distinguish the effects of decreased vessel leakiness from those due to network structural changes in clinical trials or animal studies. We have developed a mathematical model to calculate blood flow in complex tumor networks imaged by two-photon microscopy. The model incorporates the necessary and sufficient components for addressing the problem of normalization of tumor vasculature: i) lattice-Boltzmann calculations of the full flow field within the vasculature and within the tissue, ii) diffusion and convection of soluble species such as oxygen or drugs within vessels and the tissue domain, iii) distinct and spatially-resolved vessel hydraulic conductivities and permeabilities for each species, iv) erythrocyte particles advecting in the flow and delivering oxygen with real oxygen release kinetics, v) shear stress-mediated vascular remodeling. This model, guided by multi-parameter intravital imaging of tumor vessel structure

  1. Maury Journals - German Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — German vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  2. Gram staining of protected pulmonary specimens in the early diagnosis of ventilator-associated pneumonia.

    Science.gov (United States)

    Mimoz, O; Karim, A; Mazoit, J X; Edouard, A; Leprince, S; Nordmann, P

    2000-11-01

    We evaluated prospectively the use of Gram staining of protected pulmonary specimens to allow the early diagnosis of ventilator-associated pneumonia (VAP), compared with the use of 60 bronchoscopic protected specimen brushes (PSB) and 126 blinded plugged telescopic catheters (PTC) obtained from 134 patients. Gram stains were from Cytospin slides; they were studied for the presence of microorganisms in 10 and 50 fields by two independent observers and classified according to their Gram stain morphology. Quantitative cultures were performed after serial dilution and plating on appropriate culture medium. A final diagnosis of VAP, based on a culture of > or = 10(3) c.f.u. ml-1, was established after 81 (44%) samplings. When 10 fields were analysed, a strong relationship was found between the presence of bacteria on Gram staining and the final diagnosis of VAP (for PSB and PTC respectively: sensitivity 74 and 81%, specificity 94 and 100%, positive predictive value 91 and 100%, negative predictive value 82 and 88%). The correlation was less when we compared the morphology of microorganisms observed on Gram staining with those of bacteria obtained from quantitative cultures (for PSB and PTC respectively: sensitivity 54 and 69%, specificity 86 and 89%, positive predictive value 72 and 78%, negative predictive value 74 and 84%). Increasing the number of fields read to 50 was associated with a slight decrease in specificity and positive predictive value of Gram staining, but with a small increase in its sensitivity and negative predictive value. The results obtained by the two observers were similar to each other for both numbers of fields analysed. Gram staining of protected pulmonary specimens performed on 10 fields predicted the presence of VAP and partially identified (using Gram stain morphology) the microorganisms growing at significant concentrations, and could help in the early choice of the treatment of VAP. Increasing the number of fields read or having the Gram

  3. The comparison of pyrosequencing molecular Gram stain, culture, and conventional Gram stain for diagnosing orthopaedic infections.

    Science.gov (United States)

    Kobayashi, Naomi; Bauer, Thomas W; Tuohy, Marion J; Lieberman, Isador H; Krebs, Viktor; Togawa, Daisuke; Fujishiro, Takaaki; Procop, Gary W

    2006-08-01

    We have developed a combined real-time PCR and pyrosequencing assay that successfully differentiated the vast majority of gram-positive and gram-negative bacteria when bacterial isolates were tested. The purpose of this study was to evaluate this assay on clinical specimens obtained from orthopedic surgeries, and to prospectively compare the results of "molecular Gram stain" with culture and conventional direct Gram stain. Forty-five surgical specimens were obtained from patients who underwent orthopedic surgery procedures. The DNA was extracted and a set of broad-range PCR primers that targeted a part of the 16S rDNA gene was used for pan-bacterial PCR. The amplicons were submitted for pyrosequencing and the resulting molecular Gram stain characteristics were recorded. Culture and direct Gram staining were performed using standard methods for all cases. Surgical specimens were reviewed histologically for all cases that had a discrepancy between culture and molecular results. There was an 86.7% (39/45) agreement between the traditional and molecular methods. In 12/14 (85.7%) culture-proven cases of bacterial infection, molecular Gram stain characteristics were in agreement with the culture results, while the conventional Gram stain result was in agreement only for five cases (35.7%). In the 31 culture negative cases, 27 cases were also PCR negative, whereas 4 were PCR positive. Three of these were characterized as gram negative and one as gram positive by this molecular method. Molecular determination of the Gram stain characteristics of bacteria that cause orthopedic infections may be achieved, in most instances, by this method. Further studies are necessary to understand the clinical importance of PCR-positive/culture-negative results.

  4. Histological Stains: A Literature Review and Case Study.

    Science.gov (United States)

    Alturkistani, Hani A; Tashkandi, Faris M; Mohammedsaleh, Zuhair M

    2015-06-25

    The history of histology indicates that there have been significant changes in the techniques used for histological staining through chemical, molecular biology assays and immunological techniques, collectively referred to as histochemistry. Early histologists used the readily available chemicals to prepare tissues for microscopic studies; these laboratory chemicals were potassium dichromate, alcohol and the mercuric chloride to harden cellular tissues. Staining techniques used were carmine, silver nitrate, Giemsa, Trichrome Stains, Gram Stain and Hematoxylin among others. The purpose of this research was to assess past and current literature reviews, as well as case studies, with the aim of informing ways in which histological stains have been improved in the modern age. Results from the literature review has indicated that there has been an improvement in histopathology and histotechnology in stains used. There has been a rising need for efficient, accurate and less complex staining procedures. Many stain procedures are still in use today, and many others have been replaced with new immunostaining, molecular, non-culture and other advanced staining techniques. Some staining methods have been abandoned because the chemicals required have been medically proven to be toxic. The case studies indicated that in modern histology a combination of different stain techniques are used to enhance the effectiveness of the staining process. Currently, improved histological stains, have been modified and combined with other stains to improve their effectiveness.

  5. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    This invention relates to an apparatus and method for sealing the cold leg nozzles of a nuclear reactor pressure vessel from a remote location during maintenance and inspection of associated steam generators and pumps while the pressure vessel and refueling canal are filled with water. The apparatus includes a sealing plug for mechanically sealing the cold leg nozzle from the inside of a reactor pressure vessel. The sealing plugs include a primary and a secondary O-ring. An installation tool is suspended within the reactor vessel and carries the sealing plug. The tool telescopes to insert the sealing plug within the cold leg nozzle, and to subsequently remove the plug. Hydraulic means are used to activate the sealing plug, and support means serve to suspend the installation tool within the reactor vessel during installation and removal of the sealing plug

  6. Containment vessel drain system

    Science.gov (United States)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  7. A two-temperature model for selective photothermolysis laser treatment of port wine stains

    International Nuclear Information System (INIS)

    Li, D.; Wang, G.X.; He, Y.L.; Kelly, K.M.; Wu, W.J.; Wang, Y.X.; Ying, Z.X.

    2013-01-01

    Selective photothermolysis is the basic principle for laser treatment of vascular malformations such as port wine stain birthmarks (PWS). During cutaneous laser surgery, blood inside blood vessels is heated due to selective absorption of laser energy, while the surrounding normal tissue is spared. As a result, the blood and the surrounding tissue experience a local thermodynamic non-equilibrium condition. Traditionally, the PWS laser treatment process was simulated by a discrete-blood-vessel model that simplifies blood vessels into parallel cylinders buried in a multi-layer skin model. In this paper, PWS skin is treated as a porous medium made of tissue matrix and blood in the dermis. A two-temperature model is constructed following the local thermal non-equilibrium theory of porous media. Both transient and steady heat conduction problems are solved in a unit cell for the interfacial heat transfer between blood vessels and the surrounding tissue to close the present two-temperature model. The present two-temperature model is validated by good agreement with those from the discrete-blood-vessel model. The characteristics of the present two-temperature model are further illustrated through a comparison with the previously-used homogenous model, in which a local thermodynamic equilibrium assumption between the blood and the surrounding tissue is employed. -- Highlights: • Local thermal non-equilibrium theory was adapted in field of laser dermatology. • Transient interfacial heat transfer coefficient between two phases is presented. • Less PWS blood vessel micro-structure information is required in present model. • Good agreement between present model and classical discrete-blood-vessel model

  8. Cell wall staining with Trypan Blue enables quantitative analysis of morphological changes in yeast cells

    Directory of Open Access Journals (Sweden)

    Johannes eLiesche

    2015-02-01

    Full Text Available Yeast cells are protected by a cell wall that plays an important role in the exchange of substances with the environment. The cell wall structure is dynamic and can adapt to different physiological states or environmental conditions. For the investigation of morphological changes, selective staining with fluorescent dyes is a valuable tool. Furthermore, cell wall staining is used to facilitate sub-cellular localization experiments with fluorescently-labeled proteins and the detection of yeast cells in non-fungal host tissues. Here, we report staining of Saccharomyces cerevisiae cell wall with Trypan Blue, which emits strong red fluorescence upon binding to chitin and yeast glucan; thereby, it facilitates cell wall analysis by confocal and super-resolution microscopy. The staining pattern of Trypan Blue was similar to that of the widely used UV-excitable, blue fluorescent cell wall stain Calcofluor White. Trypan Blue staining facilitated quantification of cell size and cell wall volume when utilizing the optical sectioning capacity of a confocal microscope. This enabled the quantification of morphological changes during growth under anaerobic conditions and in the presence of chemicals, demonstrating the potential of this approach for morphological investigations or screening assays.

  9. Cell wall staining with Trypan blue enables quantitative analysis of morphological changes in yeast cells.

    Science.gov (United States)

    Liesche, Johannes; Marek, Magdalena; Günther-Pomorski, Thomas

    2015-01-01

    Yeast cells are protected by a cell wall that plays an important role in the exchange of substances with the environment. The cell wall structure is dynamic and can adapt to different physiological states or environmental conditions. For the investigation of morphological changes, selective staining with fluorescent dyes is a valuable tool. Furthermore, cell wall staining is used to facilitate sub-cellular localization experiments with fluorescently-labeled proteins and the detection of yeast cells in non-fungal host tissues. Here, we report staining of Saccharomyces cerevisiae cell wall with Trypan Blue, which emits strong red fluorescence upon binding to chitin and yeast glucan; thereby, it facilitates cell wall analysis by confocal and super-resolution microscopy. The staining pattern of Trypan Blue was similar to that of the widely used UV-excitable, blue fluorescent cell wall stain Calcofluor White. Trypan Blue staining facilitated quantification of cell size and cell wall volume when utilizing the optical sectioning capacity of a confocal microscope. This enabled the quantification of morphological changes during growth under anaerobic conditions and in the presence of chemicals, demonstrating the potential of this approach for morphological investigations or screening assays.

  10. Port wine stain on a child's face (image)

    Science.gov (United States)

    Port wine stains are always present at birth. In an infant, they are flat, pink, vascular lesions. Common locations ... may be present anywhere on the body. Port wine stains may appear in association with other syndromes.

  11. NCSX Vacuum Vessel Fabrication

    International Nuclear Information System (INIS)

    Viola ME; Brown T; Heitzenroeder P; Malinowski F; Reiersen W; Sutton L; Goranson P; Nelson B; Cole M; Manuel M; McCorkle D.

    2005-01-01

    The National Compact Stellarator Experiment (NCSX) is being constructed at the Princeton Plasma Physics Laboratory (PPPL) in conjunction with the Oak Ridge National Laboratory (ORNL). The goal of this experiment is to develop a device which has the steady state properties of a traditional stellarator along with the high performance characteristics of a tokamak. A key element of this device is its highly shaped Inconel 625 vacuum vessel. This paper describes the manufacturing of the vessel. The vessel is being fabricated by Major Tool and Machine, Inc. (MTM) in three identical 120 o vessel segments, corresponding to the three NCSX field periods, in order to accommodate assembly of the device. The port extensions are welded on, leak checked, cut off within 1-inch of the vessel surface at MTM and then reattached at PPPL, to accommodate assembly of the close-fitting modular coils that surround the vessel. The 120 o vessel segments are formed by welding two 60 o segments together. Each 60 o segment is fabricated by welding ten press-formed panels together over a collapsible welding fixture which is needed to precisely position the panels. The vessel is joined at assembly by welding via custom machined 8-inch (20.3 cm) wide spacer ''spool pieces''. The vessel must have a total leak rate less than 5 X 10 -6 t-l/s, magnetic permeability less than 1.02(micro), and its contours must be within 0.188-inch (4.76 mm). It is scheduled for completion in January 2006

  12. Modified Genta triple stain for identifying Helicobacter pylori.

    OpenAIRE

    el-Zimaity, H M; Wu, J; Graham, D Y

    1999-01-01

    AIM: To evaluate whether lead nitrate could replace uranyl nitrate in the Genta stain for H pylori without sacrificing the advantages of the triple stain (Steiner silver impregnation combined with Alcian blue and haematoxylin/eosin (H&E)). METHODS: A comparison was made in 16 specimens between the original triple stain and the revised version. One pathologist evaluated all sections. RESULTS: Direct substitution of lead nitrate for uranium nitrate produced well stained organisms without interf...

  13. Utility of Modified Ultrafast Papanicolaou Stain in Cytological Diagnosis.

    Science.gov (United States)

    Sinkar, Prachi; Arakeri, Surekha Ulhas

    2017-03-01

    Need for minimal turnaround time for assessing Fine Needle Aspiration Cytology (FNAC) has encouraged innovations in staining techniques that require lesser staining time with unequivocal cell morphology. The standard protocol for conventional Papanicolaou (PAP) stain requires about 40 minutes. To overcome this, Ultrafast Papanicolaou (UFP) stain was introduced which reduces staining time to 90 seconds and also enhances the quality. However, reagents required for this were not easily available hence, Modified Ultrafast Papanicolaou (MUFP) stain was introduced subsequently. To assess the efficacy of MUFP staining by comparing the quality of MUFP stain with conventional PAP stain. FNAC procedure was performed by using 10 ml disposable syringe and 22-23 G needle. Total 131 FNAC cases were studied which were lymph node (30), thyroid (38), breast (22), skin and soft tissue (24), salivary gland (11) and visceral organs (6). Two smears were prepared and stained by MUFP and conventional PAP stain. Scores were given on four parameters: background of smears, overall staining pattern, cell morphology and nuclear staining. Quality Index (QI) was calculated from ratio of total score achieved to maximum score possible. Statistical analysis using chi square test was applied to each of the four parameters before obtaining the QI in both stains. Students t-test was applied to evaluate the efficacy of MUFP in comparison with conventional PAP stain. The QI of MUFP for thyroid, breast, lymph node, skin and soft tissue, salivary gland and visceral organs was 0.89, 0.85, 0.89, 0.83, 0.92, and 0.78 respectively. Compared to conventional PAP stain QI of MUFP smears was better in all except visceral organ cases and was statistically significant. MUFP showed clear red blood cell background, transparent cytoplasm and crisp nuclear features. MUFP is fast, reliable and can be done with locally available reagents with unequivocal morphology which is the need of the hour for a cytopathology set-up.

  14. Radioactive waste processing vessel

    International Nuclear Information System (INIS)

    Hayashi, Masaru; Suzuki, Osamu; Ishizaki, Kanjiro.

    1987-01-01

    Purpose: To obtain a vessel of a reduced weight and with no external leaching of radioactive materials. Constitution: The vessel main body is constituted, for example, with light weight concretes or foamed concretes, particularly, foamed concretes containing fine closed bubbles in the inside. Then, layers having dense texture made of synthetic resin such as polystylene, vinylchloride resin, etc. or metal plate such as stainless plate are integrally disposed to the inner surface of the vessel main body. The cover member also has the same structure. (Sekiya, K.)

  15. Tempest in a vessel

    International Nuclear Information System (INIS)

    Barre, Bertrand

    2015-01-01

    As the ASN made some statements about anomalies of carbon content in the EPR vessel bottom and top, the author recalls and comments some technical issues to better understand the information published on this topic. He notably addresses the role of the vessel, briefly indicates its operating conditions, shape and structure, and mechanical components for the top, its material and mechanical properties, and test samples used to assess mechanical properties. He also comments the phenomenon of radio-induced embrittlement, the vessel manufacturing process, and evokes the applicable regulations. He quotes and comments statements made by the ASN and Areva which evoke further assessments of the concerned components

  16. 7 CFR 28.442 - Middling Yellow Stained Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Middling Yellow Stained Color. 28.442 Section 28.442... Stained Color. Middling Yellow Stained Color is American Upland cotton which in color is deeper than Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] below color grade cotton ...

  17. 7 CFR 28.441 - Strict Middling Yellow Stained Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Middling Yellow Stained Color. 28.441 Section... Strict Middling Yellow Stained Color. Strict Middling Yellow Stained Color is color which is deeper than that of Strict Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] ...

  18. CD3 immunohistochemical staining in diagnosis of lymphocytic colitis

    DEFF Research Database (Denmark)

    Fiehn, Anne-Marie Kanstrup; Engel, Ulla; Holck, Susanne

    2016-01-01

    and eosin (HE) stainings were available. At the second assessment, a supplementary CD3 immunohistochemical staining was also available. The aim was to evaluate whether a supplementary CD3 would increase the diagnostic agreement among pathologists, and whether a CD3 stain would change the diagnosis based...

  19. Cheboygan Vessel Base

    Data.gov (United States)

    Federal Laboratory Consortium — Cheboygan Vessel Base (CVB), located in Cheboygan, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). CVB was established by congressional...

  20. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  1. 2011 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  2. 2011 Fishing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  3. Pressurized Vessel Slurry Pumping

    International Nuclear Information System (INIS)

    Pound, C.R.

    2001-01-01

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air

  4. 2013 Tanker Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  5. Maury Journals - US Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — U.S. vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  6. Coastal Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains catch (landed catch) and effort for fishing trips made by vessels that have been issued a Federal permit for the Gulf of Mexico reef fish,...

  7. In-vessel tritium

    International Nuclear Information System (INIS)

    Ueda, Yoshio; Ohya, Kaoru; Ashikawa, Naoko; Ito, Atsushi M.; Kato, Daiji; Kawamura, Gakushi; Takayama, Arimichi; Tomita, Yukihiro; Nakamura, Hiroaki; Ono, Tadayoshi; Kawashima, Hisato; Shimizu, Katsuhiro; Takizuka, Tomonori; Nakano, Tomohide; Nakamura, Makoto; Hoshino, Kazuo; Kenmotsu, Takahiro; Wada, Motoi; Saito, Seiki; Takagi, Ikuji; Tanaka, Yasunori; Tanabe, Tetsuo; Yoshida, Masafumi; Toma, Mitsunori; Hatayama, Akiyoshi; Homma, Yuki; Tolstikhina, Inga Yu.

    2012-01-01

    The in-vessel tritium research is closely related to the plasma-materials interaction. It deals with the edge-plasma-wall interaction, the wall erosion, transport and re-deposition of neutral particles and the effect of neutral particles on the fuel recycling. Since the in-vessel tritium shows a complex nonlinear behavior, there remain many unsolved problems. So far, behaviors of in-vessel tritium have been investigated by two groups A01 and A02. The A01 group performed experiments on accumulation and recovery of tritium in thermonuclear fusion reactors and the A02 group studied theory and simulation on the in-vessel tritium behavior. In the present article, outcomes of the research are reviewed. (author)

  8. Reactor pressure vessel support

    International Nuclear Information System (INIS)

    Butti, J.P.

    1977-01-01

    A link and pin support system provides the primary vertical and lateral support for a nuclear reactor pressure vessel without restricting thermally induced radial and vertical expansion and contraction. (Auth.)

  9. 2013 Cargo Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  10. 2013 Fishing Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  11. 2013 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  12. Ocean Station Vessel

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean Station Vessels (OSV) or Weather Ships captured atmospheric conditions while being stationed continuously in a single location. While While most of the...

  13. Vessel Sewage Discharges

    Science.gov (United States)

    Vessel sewage discharges are regulated under Section 312 of the Clean Water Act, which is jointly implemented by the EPA and Coast Guard. This homepage links to information on marine sanitation devices and no discharge zones.

  14. Reactor pressure vessel design

    International Nuclear Information System (INIS)

    Foehl, J.

    1998-01-01

    As a result of the popularity of the Agencies report 'Neutron Irradiation Embrittlement of Reactor Pressure Vessel Steels' of 1975, it was decided that another report on this broad subject would be of use. In this report, background and contemporary views on specially identified areas of the subject are considered as self-contained chapters, written by experts. In chapter 2, the general principles of reactor pressure vessel design are elaborated. Crack and fracture initiation and propagation are treated in some detail

  15. Graywater Discharges from Vessels

    Science.gov (United States)

    2011-11-01

    metals (e.g., cadmium, chromium, lead, copper , zinc, silver, nickel, and mercury), solids, and nutrients (USEPA, 2008b; USEPA 2010). Wastewater from... flotation ), and disinfection (using ultraviolet light) as compared to traditional Type II MSDs that use either simple maceration and chlorination, or...Coliform Naval Vessels Oceanographic Vessels Small Cruise Ships 25a Vendor 2 Hamann AG Biological Treatment with Dissolved Air Flotation and

  16. Centrifuge-operated specimen staining method and apparatus

    Science.gov (United States)

    Clarke, Mark S. F. (Inventor); Feeback, Daniel L. (Inventor)

    1999-01-01

    A method of staining preselected, mounted specimens of either biological or nonbiological material enclosed within a staining chamber where the liquid staining reagents are applied and removed from the staining chamber using hypergravity as the propelling force. In the preferred embodiment, a spacecraft-operated centrifuge and method of diagnosing biological specimens while in orbit, characterized by hermetically sealing a shell assembly. The assembly contains slide stain apparatus with computer control therefor, the operative effect of which is to overcome microgravity, for example on board an International Space Station.

  17. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  18. Nonlinear multicontrast microscopy of hematoxylin-and-eosin-stained histological sections

    Science.gov (United States)

    Tuer, Adam; Tokarz, Danielle; Prent, Nicole; Cisek, Richard; Alami, Jennifer; Dumont, Daniel J.; Bakueva, Ludmila; Rowlands, John; Barzda, Virginijus

    2010-03-01

    Imaging hematoxylin-and-eosin-stained cancerous histological sections with multicontrast nonlinear excitation fluorescence, second- and third-harmonic generation (THG) microscopy reveals cellular structures with extremely high image contrast. Absorption and fluorescence spectroscopy together with second hyperpolarizability measurements of the dyes shows that strong THG appears due to neutral hemalum aggregation and is subsequently enhanced by interaction with eosin. Additionally, fluorescence lifetime imaging microscopy reveals eosin fluorescence quenching by hemalums, showing better suitability of only eosin staining for fluorescence microscopy. Multicontrast nonlinear microscopy has the potential to differentiate between cancerous and healthy tissue at a single cell level.

  19. Hirschsprung's disease diagnosis: Comparison of immunohistochemical, hematoxilin and eosin staining

    Science.gov (United States)

    Memarzadeh, Mehrdad; Talebi, Ardeshir; Edalaty, Masod; Hosseinpour, Mehrdad; Vahidi, Nasrin

    2009-01-01

    Background: The diagnosis of Hirschsprung's disease (HD) is based on the absence of ganglion cells. In hemotoxilin and eosin (H and E) as well as acetylcholine esterase staining there are limitations in the diagnosis of immature ganglion cells in neonates. Methods: In this prospective study, 54 biopsies taken from suspected HD patients (five mucosal specimens and 49 full thickness specimens) were studied. In the laboratory, after preparing sections of paraffin embedded tissues, H and E staining slides were compared with immunohistochemical (IHC) staining including: S100, NSE, CD117, CD56, Cathepsin D, Vimentin, BCL2, GFAP, Synaptophysin and chromogranin. Results: The study revealed 30 negative (absence of ganglion cells) cases (55.5%), 17 positive cases (31.04%) and seven suspected cases (12.9%) of ganglion cells on the H and E staining. On IHC staining with CD56 and Cathepsin D, all of the 17 positive cases detected through H and E, were confirmed for having ganglion cells and out of 30 cases reported negative on H and E staining, 28(93.3%) were reported negative and two (6.7%) positive by IHC staining. Of the seven suspected cases H and E staining), IHC staining detectedganglion cells only in five slides; two remained negative. Conclusions: IHC staining using CD56 and Cathepsin D improved the accuracy of diagnosis in HD when used in addition to H and E staining technique, especially for negative or suspicious slides. PMID:20671847

  20. FFTF and CRBRP reactor vessels

    International Nuclear Information System (INIS)

    Morgan, R.E.

    1977-01-01

    The Fast Flux Test Facility (FFTF) reactor vessel and the Clinch River Breeder Reactor Plant (CRBRP) reactor vessel each serve to enclose a fast spectrum reactor core, contain the sodium coolant, and provide support and positioning for the closure head and internal structure. Each vessel is located in its reactor cavity and is protected by a guard vessel which would ensure continued decay heat removal capability should a major system leak develop. Although the two plants have significantly different thermal power ratings, 400 megawatts for FFTF and 975 megawatts for CRBRP, the two reactor vessels are comparable in size, the CRBRP vessel being approximately 28% longer than the FFTF vessel. The FFTF vessel diameter was controlled by the space required for the three individual In-Vessel Handling Machines and Instrument Trees. Utilization of the triple rotating plug scheme for CRBRP refueling enables packaging of the larger CRBRP core in a vessel the same diameter as the FFTF vessel

  1. Electrostatic control of the coffee stain effect

    Science.gov (United States)

    Wray, Alex; Papageorgiou, Demetrios; Sefiane, Khellil; Matar, Omar

    2013-11-01

    The ``coffee stain effect,'' as first explained by Deegan et al. 1997, has received a great deal of attention amongst modellers and experimentalists in recent years, perhaps due in part to its obvious casual familiarity. However, it maintains interest because of its intriguing reliance on an interplay of a trio of effects: contact line pinning, inhomogeneous mass flux, and resulting capillarity-driven flow. What is more, the effect, and especially its suppression or reversal, find applications in fields as diverse as sample recovery, mass spectroscopy and the printing of Organic LEDs. We examine the motion a nanoparticle-laden droplet deposited on a precursor film, incorporating the effects of capillarity, concentration-dependent rheology, together with a heated substrate and resultant mass flux and Marangoni effects. We allow the substrate to act as an electrode and incorporate a second electrode above the droplet. The potential difference together with a disparity in electrical properties between the two regions results in electrical (Maxwell) stresses at the interface. We show via lubrication theory and via direct numerical simulations that the ring effect typically observed may be suppressed or augmented via appropriate use of electric fields. EPSRC DTG

  2. Erbium doped stain etched porous silicon

    International Nuclear Information System (INIS)

    Gonzalez-Diaz, B.; Diaz-Herrera, B.; Guerrero-Lemus, R.; Mendez-Ramos, J.; Rodriguez, V.D.; Hernandez-Rodriguez, C.; Martinez-Duart, J.M.

    2008-01-01

    In this work a simple erbium doping process applied to stain etched porous silicon layers (PSLs) is proposed. This doping process has been developed for application in porous silicon solar cells, where conventional erbium doping processes are not affordable because of the high processing cost and technical difficulties. The PSLs were formed by immersion in a HF/HNO 3 solution to properly adjust the porosity and pore thickness to an optimal doping of the porous structure. After the formation of the porous structure, the PSLs were analyzed by means of nitrogen BET (Brunauer, Emmett and Teller) area measurements and scanning electron microscopy. Subsequently, the PSLs were immersed in a saturated erbium nitrate solution in order to cover the porous surface. Then, the samples were subjected to a thermal process to activate the Er 3+ ions. Different temperatures and annealing times were used in this process. The photoluminescence of the PSLs was evaluated before and after the doping processes and the composition was analyzed by Fourier transform IR spectroscopy

  3. Lymphatic vessels assessment in feline mammary tumours

    International Nuclear Information System (INIS)

    Sarli, Giuseppe; Sassi, Francesco; Brunetti, Barbara; Rizzo, Antonio; Diracca, Laura; Benazzi, Cinzia

    2007-01-01

    The lymphatic vessels play a crucial role in a variety of human cancers since tumour cell lymphatic invasion significantly influences prognosis. It is not known if pre-existing lymphatics are enough for tumour dissemination or de novo development is necessary. VEGFR-3 is an angiogenetic mediator for both lymphatic and blood vessels during embryonic development, and only for lymphatics after birth. VEGF is a mediator of both vasculogenesis and angiogenesis, regulates the growth of lymphatics in various experimental models, and is produced in many solid tumours. CD44 mediates hyaluronic acid (HA)-dependent cell adhesion: besides promoting invasion, this interaction also supports neoangiogenesis that indirectly stimulates tumour cell proliferation. The expression of VEGF-C (Vascular Endothelial Growth Factor – C), its receptor VEGFR-3 and CD44, were studied on feline mammary samples to assess the importance of lymphangiogenesis and lymphangiotrophism in neoplasia. Samples were taken from six normal mammary glands (NMG), ten benign (BT) and 32 malignant (MT) tumours. Immunohistochemical laminin/VEGFR-3 double stain, VEGF-C and CD44 stains were applied to 4 μm-thick sections, and their expression evaluated in intratumoral/extratumoral and intramammary/extramammary fields. All groups revealed a higher number of lymphatics in the extratumoral/extramammary areas. VEGF-C expression in the epithelium paralleled the number of positive vessels in the NMG, BT and MT, whereas VEGF-C higher expression was noted in the intratumoral fields only in infiltrating MT. CD44 score was lower in extratumoral than intratumoral fields in tumours and showed a significant increase in extramammary/extratumoral fields from NMG to MT. Pearson test showed a significant and inversely proportional correlation between CD44 expression and the number of lymphatic vessels with VEGFR-3 in malignant infiltrating tumours. The number of both VEGFR-3 positive and negative lymphatics in the extratumoral

  4. Myocytes of chorionic vessels from placentas with meconium-associated vascular necrosis exhibit apoptotic markers.

    Science.gov (United States)

    King, Erin L; Redline, Raymond W; Smith, Steven D; Kraus, Frederick T; Sadovsky, Yoel; Nelson, D Michael

    2004-04-01

    Meconium-associated vascular necrosis (MAVN) is a histological abnormality of human placental chorionic vessels that is associated with poor neonatal outcome. We tested the hypothesis that MAVN shows apoptosis in the walls of chorionic vessels. Archival placental specimens with MAVN (n = 5) were compared with specimens from uncomplicated pregnancies at term (n = 5) and from placentas with intense chorionic vasculitis associated with acute chorioamnionitis with (n = 5) or without (n = 5) a clinical history of meconium in the amniotic fluid. Sections from all placentas were processed by the TUNEL method, and 2 observers who were blinded to specimen diagnosis quantified the immunofluorescent TUNEL staining in both the amnion-facing and villous-facing walls of the larger chorionic vessels in each specimen. Compared with the other 3 groups, only the amnion-facing wall of chorionic vessels in MAVN showed a significantly greater number of apoptotic cells. This was verified by morphological criteria and caspase 3 staining. There were limited or no detectable TUNEL-stained cells in either the villous-facing walls of vessels in the MAVN specimens or in any of the vessels of the placentas from uncomplicated pregnancies. There was a negligible level of apoptosis in chorionic vessels of placentas with intense chorionic vasculitis, with or without meconium, despite the inflammatory response or presence of meconium. We conclude that apoptosis contributes to the pathophysiology of MAVN.

  5. Acrylic vessel cleaning tests

    International Nuclear Information System (INIS)

    Earle, D.; Hahn, R.L.; Boger, J.; Bonvin, E.

    1997-01-01

    The acrylic vessel as constructed is dirty. The dirt includes blue tape, Al tape, grease pencil, gemak, the glue or residue form these tapes, finger prints and dust of an unknown composition but probably mostly acrylic dust. This dirt has to be removed and once removed, the vessel has to be kept clean or at least to be easily cleanable at some future stage when access becomes much more difficult. The authors report on the results of a series of tests designed: (a) to prepare typical dirty samples of acrylic; (b) to remove dirt stuck to the acrylic surface; and (c) to measure the optical quality and Th concentration after cleaning. Specifications of the vessel call for very low levels of Th which could come from tape residues, the grease pencil, or other sources of dirt. This report does not address the concerns of how to keep the vessel clean after an initial cleaning and during the removal of the scaffolding. Alconox is recommended as the cleaner of choice. This acrylic vessel will be used in the Sudbury Neutrino Observatory

  6. Radioactive liquid containing vessel

    International Nuclear Information System (INIS)

    Sakurada, Tetsuo; Kawamura, Hironobu.

    1993-01-01

    Cooling jackets are coiled around the outer circumference of a container vessel, and the outer circumference thereof is covered with a surrounding plate. A liquid of good conductivity (for example, water) is filled between the cooling jackets and the surrounding plate. A radioactive liquid is supplied to the container vessel passing through a supply pipe and discharged passing through a discharge pipe. Cooling water at high pressure is passed through the cooling water jackets in order to remove the heat generated from the radioactive liquid. Since cooling water at high pressure is thus passed through the coiled pipes, the wall thickness of the container vessel and the cooling water jackets can be reduced, thereby enabling to reduce the cost. Further, even if the radioactive liquid is leaked, there is no worry of contaminating cooling water, to prevent contamination. (I.N.)

  7. Efficacy test of a toothpaste in reducing extrinsic dental stain

    Science.gov (United States)

    Agustanti, A.; Ramadhani, S. A.; Adiatman, M.; Rahardjo, A.; Callea, M.; Yavuz, I.; Maharani, D. A.

    2017-08-01

    This clinical trial compared the external dental stain reduction achieved by tested toothpaste versus placebo in adult patients. In this double-blind, parallel, randomised clinical trial, 45 female volunteers with a mean age of 20 years old were included. All study subjects front teeth were topically applicated with Silver Diamine Fluoride (SDF) to create external dental stains. Subjects were randomized into test (n=22) and control (n=23) groups. Toothpastes were used for two days to analyse the effects of removing external stains on the labial surfaces of all anterior teeth. VITA Easyshade Advance 4.0 was used to measure dental extrinsic stains changes. The analysis showed statistically significant efficacy of the tested toothpaste in reducing external dental stain caused by SDF, comparing to the placebo toothpaste, after one and two days of usage. The tested toothpaste was effective in reducing dental stain.

  8. Post-staining electroblotting for efficient and reliable peptide blotting.

    Science.gov (United States)

    Lee, Der-Yen; Chang, Geen-Dong

    2015-01-01

    Post-staining electroblotting has been previously described to transfer Coomassie blue-stained proteins from polyacrylamide gel onto polyvinylidene difluoride (PVDF) membranes. Actually, stained peptides can also be efficiently and reliably transferred. Because of selective staining procedures for peptides and increased retention of stained peptides on the membrane, even peptides with molecular masses less than 2 kDa such as bacitracin and granuliberin R are transferred with satisfactory results. For comparison, post-staining electroblotting is about 16-fold more sensitive than the conventional electroblotting for visualization of insulin on the membrane. Therefore, the peptide blots become practicable and more accessible to further applications, e.g., blot overlay detection or immunoblotting analysis. In addition, the efficiency of peptide transfer is favorable for N-terminal sequence analysis. With this method, peptide blotting can be normalized for further analysis such as blot overlay assay, immunoblotting, and N-terminal sequencing for identification of peptide in crude or partially purified samples.

  9. Gram staining in the diagnosis of acute septic arthritis.

    Science.gov (United States)

    Faraj, A A; Omonbude, O D; Godwin, P

    2002-10-01

    This study aimed at determining the sensitivity and specificity of Gram staining of synovial fluid as a diagnostic tool in acute septic arthritis. A retrospective study was made of 22 patients who had arthroscopic lavage following a provisional diagnosis of acute septic arthritis of the knee joint. Gram stains and cultures of the knee aspirates were compared with the clinical and laboratory parameters, to evaluate their usefulness in diagnosing acute arthritis. All patients who had septic arthritis had pain, swelling and limitation of movement. CRP was elevated in 90% of patients. The incidence of elevated white blood cell count was higher in the group of patients with a positive Gram stain study (60%) as compared to patients with a negative Gram stain study (33%). Gram staining sensitivity was 45%. Its specificity was however 100%. Gram staining is an unreliable tool in early decision making in patients requiring urgent surgical drainage and washout.

  10. Techniques for controlling variability in gram staining of obligate anaerobes.

    Science.gov (United States)

    Johnson, M J; Thatcher, E; Cox, M E

    1995-01-01

    Identification of anaerobes recovered from clinical samples is complicated by the fact that certain gram-positive anaerobes routinely stain gram negative; Peptostreptococcus asaccharolyticus, Eubacterium plautii, Clostridium ramosum, Clostridium symbiosum, and Clostridium clostridiiforme are among the nonconformists with regard to conventional Gram-staining procedures. Accurate Gram staining of American Type Culture Collection strains of these anaerobic bacteria is possible by implementing fixing and staining techniques within a gloveless anaerobic chamber. Under anaerobic conditions, gram-positive staining occurred in all test organisms with "quick" fixing techniques with both absolute methanol and formalin. The results support the hypothesis that, when anaerobic bacteria are exposed to oxygen, a breakdown of the physical integrity of the cell wall occurs, introducing Gram stain variability in gram-positive anaerobes. PMID:7538512

  11. A useful single-solution polychrome stain for plant material...Brook Cyte-Chrome I.

    Science.gov (United States)

    Stanley L Krugman; Julia F. Littlefield

    1968-01-01

    Fresh and chemically fixed sectioned plant material can be quickly stained by applying a Brook Cyte Chrome I polychrome stain. Staining time averaged only about 10 minutes. And exact timing of staining and de-staining is not as critical as with most of the commonly used stains. The overall quality is comparable to that of the traditional stains.

  12. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    Science.gov (United States)

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram

  13. Near-UV laser treatment of extrinsic dental enamel stains.

    Science.gov (United States)

    Schoenly, J E; Seka, W; Featherstone, J D B; Rechmann, P

    2012-04-01

    The selective ablation of extrinsic dental enamel stains using a 400-nm laser is evaluated at several fluences for completely removing stains with minimal damage to the underlying enamel. A frequency-doubled Ti:sapphire laser (400-nm wavelength, 60-nanosecond pulse duration, 10-Hz repetition rate) was used to treat 10 extracted human teeth with extrinsic enamel staining. Each tooth was irradiated perpendicular to the surface in a back-and-forth motion over a 1-mm length using an ∼300-µm-diam 10th-order super-Gaussian beam with fluences ranging from 0.8 to 6.4 J/cm(2) . Laser triangulation determined stain depth and volume removed by measuring 3D surface images before and after irradiation. Scanning electron microscopy evaluated the surface roughness of enamel following stain removal. Fluorescence spectroscopy measured spectra of unbleached and photobleached stains in the spectral range of 600-800 nm. Extrinsic enamel stains are removed with laser fluences between 0.8 and 6.4 J/cm(2) . Stains removed on sound enamel leave behind a smooth enamel surface. Stain removal in areas with signs of earlier cariogenic acid attacks resulted in isolated and randomly located laser-induced, 50-µm-diam enamel pits. These pits contain 0.5-µm diam, smooth craters indicative of heat transfer from the stain to the enamel and subsequent melting and water droplet ejection. Ablation stalling of enamel stains is typically observed at low fluences (Laser ablation of extrinsic enamel stains at 400 nm is observed to be most efficient above 3 J/cm(2) with minimal damage to the underlying enamel. Unsound underlying enamel is also observed to be selectively removed after irradiation. Copyright © 2012 Wiley Periodicals, Inc.

  14. [Histochemical stains for minerals by hematoxylin-lake method].

    Science.gov (United States)

    Miyagawa, Makoto

    2013-04-01

    The present study was undertaken to establish the experimental animal model by histological staining methods for minerals. After intraperitoneal injections of minerals, precipitates deposited on the surface of the liver. Liver tissues were fixed in paraformaldehyde, embedded in paraffin and cut into thin sections which were used as minerals containing standard section. Several reagents for histological stains and spectrophotometry for minerals were applied in both test-tube experiments and stainings of tissue sections to test for minerals. Hematoxylin-lake was found of capable of staining minerals in tissue. A simple technique used was described for light microscopic detection of minerals.

  15. Utility of Gram staining for diagnosis of Malassezia folliculitis.

    Science.gov (United States)

    Tu, Wei-Ting; Chin, Szu-Ying; Chou, Chia-Lun; Hsu, Che-Yuan; Chen, Yu-Tsung; Liu, Donald; Lee, Woan-Ruoh; Shih, Yi-Hsien

    2018-02-01

    Malassezia folliculitis (MalF) mimics acne vulgaris and bacterial folliculitis in clinical presentations. The role of Gram staining in rapid diagnosis of MalF has not been well studied. In our study, 32 patients were included to investigate the utility of Gram staining for MalF diagnosis. The final diagnoses of MalF were determined according to clinical presentation, pathological result and treatment response to antifungal agents. Our results show that the sensitivity and specificity of Gram staining are 84.6% and 100%, respectively. In conclusion, Gram staining is a rapid, non-invasive, sensitive and specific method for MalF diagnosis. © 2017 Japanese Dermatological Association.

  16. Histopathological evaluation of ocular microsporidiosis by different stains

    Directory of Open Access Journals (Sweden)

    Sharma Savitri

    2006-06-01

    Full Text Available Abstract Background There is limited data on comparing stains in the detection of microsporidia in corneal biopsies. Hence we wanted to evaluate various stains for their ability to detect microsporidia in corneal tissue sections. Methods Four cases diagnosed with microsporidiosis on Hematoxylin and Eosin and Periodic Acid Schiff's stained sections of the corneal button between January 2002 and December 2004, were included. Further sections were prospectively stained with calcofluor white, Gram, Giemsa, Masson's trichrome, acridine orange, Gomori's methenamine silver, Gram's chromotrope and modified acid fast stain. The stained sections were analyzed for the spore characteristics in terms of size, shape, color contrast, cell wall morphology, waist band in cytoplasm and ease of detection. Results All sections showed microsporidial spores as 3 – 5 μm, oval bodies. 1% acid fast, Gram's chromotrope and GMS stains provided a reliable diagnosis of microsporidia as diagnostic waist band could be identified and good contrast helped distinguish the spores from inflammatory debris. Conclusion Considering the ease of performance, cost effectiveness and rapidity of the technique, 1% acid fast stain and Gram's chromotrope stain are ideal for the detection of microsporidia.

  17. Efficacy of in-house fluorescent stain for fungus

    Directory of Open Access Journals (Sweden)

    K. R. L. Surya Kirani

    2017-01-01

    Full Text Available Context: Mycotic infections are gaining importance in the present day medicine, and definite demonstration of fungus is essential for diagnosis. Small numbers of organisms in the smear can be identified by fluorescence microscopy. Calcofluor white (CFW fluorescent stain is a textile brightener mixed with Evans blue. It is expensive and not easily available. Aims: (1 To assess the efficacy of in-house CFW fluorescent stain for fungus in relation to conventional CFW stain, histopathology, and culture. (2 To determine sensitivity, specificity, negative predictive value (NPV, and positive predictive value (PPV with culture as gold standard. Settings and Design: One hundred cases of suspected dermatophytosis and 15 cases of systemic mycosis were included in the study. Subjects and Methods: The local whitener Ranipal is added with Robin blue, another brightener, and was used to stain teased fungal cultures. Skin, hair, and nails require pretreatment with potassium hydroxide (KOH. Biopsy slides require deparaffinization and pretreatment with KOH before staining. Conventional calcofluor stain, histopathology, and culture were done. Statistical Analysis Used: Statistical analysis was performed using sensitivity, specificity, NPV, and PPV. Results: The results are consistently comparable with conventional stain. The sensitivity was 100%, specificity was 93.3%, NPV was 100%, and PPV was 85.7%. It is also cost effective when compared to commercial stains. Conclusions: In-house stain can be used for screening of fungus in direct samples, biopsies as alternative in resource-constrained laboratories.

  18. Characterization of paint layers and stained glasses

    International Nuclear Information System (INIS)

    Biagi Maino, D.; Ciancabilla, L.; Gandolfi, G.; Maino, G.; Bruni, S.; Ferriani, S.; Visparelli, D.

    2000-01-01

    been made of the so available instruments, of both the hardware and developed software, to investigate some frescoes and stained glasses of XIV-XV centuries in the Basilica of St.Petronio in Bologna, in order to study the manufacturing techniques as well as to determine whether repairs have been carried out or substitutions made of damaged parts in the past times. (author)

  19. Pressure vessel integrity 1991

    International Nuclear Information System (INIS)

    Bhandari, S.; Doney, R.O.; McDonald, M.S.; Jones, D.P.; Wilson, W.K.; Pennell, W.E.

    1991-01-01

    This volume contains papers relating to the structural integrity assessment of pressure vessels and piping, with special emphasis on nuclear industry applications. The papers were prepared for technical sessions developed under the sponsorship of the ASME Pressure Vessels and Piping Division Committees for Codes and Standards, Computer Technology, Design and Analysis, and Materials Fabrication. They were presented at the 1991 Pressure Vessels and Piping Division Conference in San Diego, California, June 23-27. The primary objective of the sponsoring organization is to provide a forum for the dissemination and discussion of information on development and application of technology for the structural integrity assessment of pressure vessels and piping. This publication includes contributions from authors from Australia, France, Japan, Sweden, Switzerland, the United Kingdom, and the United States. The papers here are organized in six sections, each with a particular emphasis as indicated in the following section titles: Fracture Technology Status and Application Experience; Crack Initiation, Propagation and Arrest; Ductile Tearing; Constraint, Stress State, and Local-Brittle-Zones Effects; Computational Techniques for Fracture and Corrosion Fatigue; and Codes and Standards for Fatigue, Fracture and Erosion/Corrosion

  20. The reactor vessel steels

    International Nuclear Information System (INIS)

    Bilous, W.; Hajewska, E.; Szteke, W.; Przyborska, M.; Wasiak, J.; Wieczorkowski, M.

    2005-01-01

    In the paper the fundamental steels using in the construction of pressure vessel water reactor are discussed. The properties of these steels as well as the influence of neutron irradiation on its degradation in the time of exploitation are also done. (authors)

  1. Vacuum distilling vessel

    Energy Technology Data Exchange (ETDEWEB)

    Reik, H

    1928-12-27

    Vacuum distilling vessel for mineral oil and the like, characterized by the ring-form or polyconal stiffeners arranged inside, suitably eccentric to the casing, being held at a distance from the casing by connecting members of such a height that in the resulting space if necessary can be arranged vapor-distributing pipes and a complete removal of the residue is possible.

  2. Visualization of vessel traffic

    NARCIS (Netherlands)

    Willems, C.M.E.

    2011-01-01

    Moving objects are captured in multivariate trajectories, often large data with multiple attributes. We focus on vessel traffic as a source of such data. Patterns appearing from visually analyzing attributes are used to explain why certain movements have occurred. In this research, we have developed

  3. GOLD PRESSURE VESSEL SEAL

    Science.gov (United States)

    Smith, A.E.

    1963-11-26

    An improved seal between the piston and die member of a piston-cylinder type pressure vessel is presented. A layer of gold, of sufficient thickness to provide an interference fit between the piston and die member, is plated on the contacting surface of at least one of the members. (AEC)

  4. Reactor vessel stud tensioner

    International Nuclear Information System (INIS)

    Malandra, L.J.; Beer, R.W.; Salton, R.B.; Spiegelman, S.R.; Cognevich, M.L.

    1982-01-01

    A quick-acting stud tensioner, for facilitating the loosening or tightening of a stud nut on a reactor vessel stud, has gripper jaws which when the tensioner is lowered into engagement with the upper end of the stud are moved inwards to grip the upper end and which when the tensioner is lifted move outward to release the upper end. (author)

  5. Accuracy of geometrical modelling of heat transfer from tissue to blood vessels

    NARCIS (Netherlands)

    Leeuwen, van G.M.J.; Kotte, A.N.T.J.; Bree, de J.; Koijk, van der J.F.; Crezee, J.; Lagendijk, J.J.W.

    1997-01-01

    We have developed a thermal model in which blood vessels are described as geometrical objects, 3D curves with associated diameters. Here the behaviour of the model is examined for low resolutions compared with the vessel diameter and for strongly curved vessels. The tests include a single straight

  6. PDX vacuum vessel stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.

    1975-01-01

    A stress analysis of PDX vacuum vessel is described and the summary of results is presented. The vacuum vessel is treated as a toroidal shell of revolution subjected to an internal vacuum. The critical buckling pressure is calculated. The effects of the geometrical discontinuity at the juncture of toroidal shell head and cylindrical outside wall, and the concavity of the cylindrical wall are examined. An effect of the poloidal field coil supports and the vessel outside supports on the stress distribution in the vacuum vessel is determined. A method evaluating the influence of circular ports in the vessel wall on the stress level in the vessel is outlined

  7. Confusion over live/dead stainings for the detection of vital microorganisms in oral biofilms--which stain is suitable?

    Science.gov (United States)

    Netuschil, Lutz; Auschill, Thorsten M; Sculean, Anton; Arweiler, Nicole B

    2014-01-11

    There is confusion over the definition of the term "viability state(s)" of microorganisms. "Viability staining" or "vital staining techniques" are used to distinguish live from dead bacteria. These stainings, first established on planctonic bacteria, may have serious shortcomings when applied to multispecies biofilms. Results of staining techniques should be compared with appropriate microbiological data. Many terms describe "vitality states" of microorganisms, however, several of them are misleading. Authors define "viable" as "capable to grow". Accordingly, staining methods are substitutes, since no staining can prove viability.The reliability of a commercial "viability" staining assay (Molecular Probes) is discussed based on the corresponding product information sheet: (I) Staining principle; (II) Concentrations of bacteria; (III) Calculation of live/dead proportions in vitro. Results of the "viability" kit are dependent on the stains' concentration and on their relation to the number of bacteria in the test. Generally this staining system is not suitable for multispecies biofilms, thus incorrect statements have been published by users of this technique.To compare the results of the staining with bacterial parameters appropriate techniques should be selected. The assessment of Colony Forming Units is insufficient, rather the calculation of Plating Efficiency is necessary. Vital fluorescence staining with Fluorescein Diacetate and Ethidium Bromide seems to be the best proven and suitable method in biofilm research.Regarding the mutagenicity of staining components users should be aware that not only Ethidium Bromide might be harmful, but also a variety of other substances of which the toxicity and mutagenicity is not reported. - The nomenclature regarding "viability" and "vitality" should be used carefully.- The manual of the commercial "viability" kit itself points out that the kit is not suitable for natural multispecies biofilm research, as supported by an

  8. Strong transthyretin immunostaining: potential pitfall in cardiac amyloid typing.

    Science.gov (United States)

    Satoskar, Anjali A; Efebera, Yvonne; Hasan, Ayesha; Brodsky, Sergey; Nadasdy, Gyongyi; Dogan, Ahmet; Nadasdy, Tibor

    2011-11-01

    Although systemic amyloidosis commonly presents with renal disease, cardiac involvement usually determines the patient's prognosis. Cardiac involvement is seen in light chain amyloid and transthyretin amyloidosis. Distinguishing between these two is critical because prognosis and treatment differ. Our study demonstrates the unreliability of transthyretin immunostaining in subtyping cardiac amyloid. Between January 2003 and August 2010, we retrieved 229 native endomyocardial biopsies, of which 24 had amyloid. Immunohistochemistry for κ, λ, transthyretin, and serum amyloid A protein was performed on formalin-fixed, paraffin-embedded sections. Staining was graded as weak (trace to 1+) or strong (2 to 3+). Mass spectrometry (MS)-based proteomic typing of microdissected amyloid material was performed on selected cases. Fifteen patients had monoclonal gammopathy/plasma cell dyscrasia with cardiac amyloid. Eight of them (53%) showed strong transthyretin staining in the cardiac amyloid deposits. MS was performed in 5 of these 8 biopsies, and all 5 biopsies revealed light chain amyloid-type amyloid. Two of these 5 light chain amyloid biopsies did not even have concomitant strong staining for the appropriate light chain. Among the 15 cases with plasma cell dyscrasia, only 7 biopsies showed strong staining for the corresponding monoclonal light chain. Strong, false-positive immunostaining for transthyretin in cardiac amyloid is a potential pitfall, augmented by the frequent lack of staining for immunoglobulin light chains. Therefore, the presence of amyloid in the cardiac biopsy should prompt a search for plasma cell dyscrasia irrespective of transthyretin staining. Confirmation with MS should be sought, particularly if there is any discrepancy between κ/λ staining and serum immunofixation results.

  9. Alcian blue-stained particles in a eutrophic lake

    DEFF Research Database (Denmark)

    Worm, J.; Søndergaard, Morten

    1998-01-01

    We used a neutral solution of Alcian Blue to stain transparent particles in eutrophic Lake Frederiksborg Slotss0, Denmark. Alcian Blue-stained particles (ABSP) appeared to be similar to the so-called transparent exopolymer particles (TEP) identified with an acidic solution of Alcian Blue. Our...

  10. News from the Biological Stain Commission No. 11

    DEFF Research Database (Denmark)

    Lyon, H O; Horobin, R W

    2012-01-01

    The 11th issue of News from the Biological Stain Commission (BSC) provides our first impressions of the REACH and ECHA programs. We intend to give a more thorough account of what these important programs actually mean in later editions of News from the Biological Stain Commission. Under the heading...

  11. Sperm viability staining in ecology and evolution: potential pitfalls

    DEFF Research Database (Denmark)

    Holman, Luke

    2009-01-01

    The causes and consequences of variation in sperm quality, survival and ageing are active areas of research in ecology and evolution. In order to address these topics, many recent studies have measured sperm viability using fluorescent staining. Although sperm viability staining has produced a nu...

  12. 21 CFR 864.1850 - Dye and chemical solution stains.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dye and chemical solution stains. 864.1850 Section 864.1850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1850 Dye and chemical...

  13. The use of special stains in liver biopsy interpretation: Implications ...

    African Journals Online (AJOL)

    Materials and Methods: The formalin fixed paraffin embedded blocks of liver biopsies reported in two histopathology laboratories between 2008 and 2013 were retrieved. These were stained with H and E and the following standard special stains for liver tissue histology – Perl's Prussian blue, reticulin, Sirius red, Shikata ...

  14. Zooming in: high resolution 3D reconstruction of differently stained histological whole slide images

    Science.gov (United States)

    Lotz, Johannes; Berger, Judith; Müller, Benedikt; Breuhahn, Kai; Grabe, Niels; Heldmann, Stefan; Homeyer, André; Lahrmann, Bernd; Laue, Hendrik; Olesch, Janine; Schwier, Michael; Sedlaczek, Oliver; Warth, Arne

    2014-03-01

    Much insight into metabolic interactions, tissue growth, and tissue organization can be gained by analyzing differently stained histological serial sections. One opportunity unavailable to classic histology is three-dimensional (3D) examination and computer aided analysis of tissue samples. In this case, registration is needed to reestablish spatial correspondence between adjacent slides that is lost during the sectioning process. Furthermore, the sectioning introduces various distortions like cuts, folding, tearing, and local deformations to the tissue, which need to be corrected in order to exploit the additional information arising from the analysis of neighboring slide images. In this paper we present a novel image registration based method for reconstructing a 3D tissue block implementing a zooming strategy around a user-defined point of interest. We efficiently align consecutive slides at increasingly fine resolution up to cell level. We use a two-step approach, where after a macroscopic, coarse alignment of the slides as preprocessing, a nonlinear, elastic registration is performed to correct local, non-uniform deformations. Being driven by the optimization of the normalized gradient field (NGF) distance measure, our method is suitable for differently stained and thus multi-modal slides. We applied our method to ultra thin serial sections (2 μm) of a human lung tumor. In total 170 slides, stained alternately with four different stains, have been registered. Thorough visual inspection of virtual cuts through the reconstructed block perpendicular to the cutting plane shows accurate alignment of vessels and other tissue structures. This observation is confirmed by a quantitative analysis. Using nonlinear image registration, our method is able to correct locally varying deformations in tissue structures and exceeds the limitations of globally linear transformations.

  15. An automated cell-counting algorithm for fluorescently-stained cells in migration assays

    Directory of Open Access Journals (Sweden)

    Novielli Nicole M

    2011-10-01

    Full Text Available Abstract A cell-counting algorithm, developed in Matlab®, was created to efficiently count migrated fluorescently-stained cells on membranes from migration assays. At each concentration of cells used (10,000, and 100,000 cells, images were acquired at 2.5 ×, 5 ×, and 10 × objective magnifications. Automated cell counts strongly correlated to manual counts (r2 = 0.99, P

  16. Tubular inverse opal scaffolds for biomimetic vessels

    Science.gov (United States)

    Zhao, Ze; Wang, Jie; Lu, Jie; Yu, Yunru; Fu, Fanfan; Wang, Huan; Liu, Yuxiao; Zhao, Yuanjin; Gu, Zhongze

    2016-07-01

    There is a clinical need for tissue-engineered blood vessels that can be used to replace or bypass damaged arteries. The success of such grafts depends strongly on their ability to mimic native arteries; however, currently available artificial vessels are restricted by their complex processing, controversial integrity, or uncontrollable cell location and orientation. Here, we present new tubular scaffolds with specific surface microstructures for structural vessel mimicry. The tubular scaffolds are fabricated by rotationally expanding three-dimensional tubular inverse opals that are replicated from colloidal crystal templates in capillaries. Because of the ordered porous structure of the inverse opals, the expanded tubular scaffolds are imparted with circumferentially oriented elliptical pattern microstructures on their surfaces. It is demonstrated that these tailored tubular scaffolds can effectively make endothelial cells to form an integrated hollow tubular structure on their inner surface and induce smooth muscle cells to form a circumferential orientation on their outer surface. These features of our tubular scaffolds make them highly promising for the construction of biomimetic blood vessels.There is a clinical need for tissue-engineered blood vessels that can be used to replace or bypass damaged arteries. The success of such grafts depends strongly on their ability to mimic native arteries; however, currently available artificial vessels are restricted by their complex processing, controversial integrity, or uncontrollable cell location and orientation. Here, we present new tubular scaffolds with specific surface microstructures for structural vessel mimicry. The tubular scaffolds are fabricated by rotationally expanding three-dimensional tubular inverse opals that are replicated from colloidal crystal templates in capillaries. Because of the ordered porous structure of the inverse opals, the expanded tubular scaffolds are imparted with circumferentially

  17. Decreased mortality associated with prompt Gram staining of blood cultures.

    Science.gov (United States)

    Barenfanger, Joan; Graham, Donald R; Kolluri, Lavanya; Sangwan, Gaurav; Lawhorn, Jerry; Drake, Cheryl A; Verhulst, Steven J; Peterson, Ryan; Moja, Lauren B; Ertmoed, Matthew M; Moja, Ashley B; Shevlin, Douglas W; Vautrain, Robert; Callahan, Charles D

    2008-12-01

    Gram stains of positive blood cultures are the most important factor influencing appropriate therapy. The sooner appropriate therapy is initiated, the better. Therefore, it is reasonable to expect that the sooner Gram stains are performed, the better. To determine the value of timely Gram stains and whether improvement in Gram stain turnaround time (TAT) is feasible, we compared data for matched pairs of patients with cultures processed promptly ( or =1 hour TAT) and then monitored TAT by control charting.In 99 matched pairs, average difference in time to detection of positive blood cultures within a pair of patients was less than 0.1 hour. For the less than 1 hour TAT group, the average TAT and crude mortality were 0.1 hour and 10.1%, respectively; for the 1 hour or longer TAT group, they were 3.3 hours and 19.2%, respectively (P Gram stains.

  18. Monitoring the magnitude of marine vessel infestation by non-indigenous ascidians in the Mediterranean.

    Science.gov (United States)

    Gewing, Mey-Tal; Shenkar, Noa

    2017-08-15

    Invasive ascidians (Chordata, Tunicata) are dominant nuisance organisms. The current study investigated the role of marine vessels in their dispersal and introduction. An examination of 45 dry-docked marine vessels, comprising recreational, commercial, and military craft, in five Israeli shipyards along the Mediterranean coast, revealed non-indigenous ascidians (NIA) on every second vessel investigated. Military vessels featured the highest ascidian abundance and richness, potentially related to their maintenance routine. Niche areas on the vessels such as sea chests and the propeller exhibited the highest occurrence of ascidians. Overall, these findings provide strong evidence that marine vessels play an acute role in NIA introduction and dispersal, with military vessels and niche areas on all the vessels being more susceptible to serving as vectors. A discovery of a new introduced species during the surveys suggests that the monitoring of marine vessels can serve as an effective tool for the early detection of NIA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Vessels in Transit - Web Tool

    Data.gov (United States)

    Department of Transportation — A web tool that provides real-time information on vessels transiting the Saint Lawrence Seaway. Visitors may sort by order of turn, vessel name, or last location in...

  20. Mapping stain distribution in pathology slides using whole slide imaging

    Directory of Open Access Journals (Sweden)

    Fang-Cheng Yeh

    2014-01-01

    Full Text Available Background: Whole slide imaging (WSI offers a novel approach to digitize and review pathology slides, but the voluminous data generated by this technology demand new computational methods for image analysis. Materials and Methods: In this study, we report a method that recognizes stains in WSI data and uses kernel density estimator to calculate the stain density across the digitized pathology slides. The validation study was conducted using a rat model of acute cardiac allograft rejection and another rat model of heart ischemia/reperfusion injury. Immunohistochemistry (IHC was conducted to label ED1 + macrophages in the tissue sections and the stained slides were digitized by a whole slide scanner. The whole slide images were tessellated to enable parallel processing. Pixel-wise stain classification was conducted to classify the IHC stains from those of the background and the density distribution of the identified IHC stains was then calculated by the kernel density estimator. Results: The regression analysis showed a correlation coefficient of 0.8961 between the number of IHC stains counted by our stain recognition algorithm and that by the manual counting, suggesting that our stain recognition algorithm was in good agreement with the manual counting. The density distribution of the IHC stains showed a consistent pattern with those of the cellular magnetic resonance (MR images that detected macrophages labeled by ultrasmall superparamagnetic iron-oxide or micron-sized iron-oxide particles. Conclusions: Our method provides a new imaging modality to facilitate clinical diagnosis. It also provides a way to validate/correlate cellular MRI data used for tracking immune-cell infiltration in cardiac transplant rejection and cardiac ischemic injury.

  1. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    An apparatus is described for sealing a cold leg nozzle of a nuclear reactor pressure vessel from a remote location comprising: at least one sealing plug for mechanically sealing the nozzle from the inside of the reactor pressure vessel. The sealing plug includes a plate and a cone assembly having an end part receptive in the nozzle, the plate being axially moveable relative to the cone assembly. The plate and cone assembly have confronting bevelled edges defining an opening therebetween. A primary O-ring is disposed about the opening and is supported on the bevelled edges, the plate being guidably mounted to the cone assembly for movement toward the cone assembly to radially expand the primary O-ring into sealing engagement with the nozzle. A means is included for providing relative movement between the outer plate and the cone assembly

  2. Mobile nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Thompson, R.E.; Spurrier, F.R.; Jones, A.R.

    1978-01-01

    A containment vessel for use in mobile nuclear reactor installations is described. The containment vessel completely surrounds the entire primary system, and is located as close to the reactor primary system components as is possible in order to minimize weight. In addition to being designed to withstand a specified internal pressure, the containment vessel is also designed to maintain integrity as a containment vessel in case of a possible collision accident

  3. Nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Blackstone, E.G.; Lofy, R.A.; Williams, L.P.

    1979-01-01

    Apparatus for the in situ inspection of a nuclear reactor vessel to detect the location and character of flaws in the walls of the vessel, in the welds joining the various sections of the vessel, in the welds joining attachments such as nozzles, elbows and the like to the reactor vessel and in such attachments wherein an inspection head carrying one or more ultrasonic transducers follows predetermined paths in scanning the various reactor sections, welds and attachments

  4. Reactor vessel stud closure system

    International Nuclear Information System (INIS)

    Spiegelman, S.R.; Salton, R.B.; Beer, R.W.; Malandra, L.J.; Cognevich, M.L.

    1982-01-01

    A quick-acting stud tensioner apparatus for enabling the loosening or tightening of a stud nut on a reactor vessel stud. The apparatus is adapted to engage the vessel stud by closing a gripper around an upper end of the vessel stud when the apparatus is seated on the stud. Upon lifting the apparatus, the gripper releases the vessel stud so that the apparatus can be removed

  5. Reactor pressure vessel steels

    International Nuclear Information System (INIS)

    Van De Velde, J.; Fabry, A.; Van Walle, E.; Chaouuadi, R.

    1998-01-01

    Research and development activities related to reactor pressure vessel steels during 1997 are reported. The objectives of activities of the Belgian Nuclear Research Centre SCK/CEN in this domain are: (1) to develop enhanced surveillance concepts by applying micromechanics and fracture-toughness tests to small specimens, and by performing damage modelling and microstructure characterization; (2) to demonstrate a methodology on a broad database; (3) to achieve regulatory acceptance and industrial use

  6. Reactor Pressure Vessel Steels

    Energy Technology Data Exchange (ETDEWEB)

    Van de Velde, J.; Fabry, A.; Van Walle, E.; Chaoudi, R

    1998-07-01

    SCK-CEN's R and D programme on Reactor Pressure Vessel (RPV) Steels in performed in support of the RVP integrity assessment. Its main objectives are: (1) to develop enhanced surveillance concepts by applying micromechanics and fracture-toughness tests to small specimens, and by performing damage modelling and microstructure characterization; (2) to demonstrate the applied methodology on a broad database; (3) to achieve regulatory acceptance and industrial use. Progress and achievements in 1999 are reported.

  7. Demonstration of lipofuscin and Nissl bodies in crystal violet stained sections using a fluorescence technique or pyronin Y stain.

    Science.gov (United States)

    Terr, L I

    1986-09-01

    This paper presents two simple, reliable methods for identification of lipofuscin and Nissl bodies in the same section. One method shows that lipofuscin stained with crystal violet retains its ability to fluoresce and can be observed under the fluorescence microscope after the stain has faded. Fading is accompanied by a gradual increase in the intensity of the fluorescence and is complete in about 5 min. Exciting illumination from this part of the spectrum also substantially fades staining of other autofluorescing tissue elements, such as lipids. Nonfluorescing structures, such as Nissl bodies, remain stained. By changing from transillumination with tungsten light to epifluorescent illumination and vice versa, both types of structures--Nissl bodies and lipofuscin--can be identified in the same section. The second technique uses pyronin Y for staining Nissl bodies in preparations previously stained with crystal violet. Nissl bodies are stained pink but lipofuscin remains violet. Lipofuscin in these sections also remains autofluorescent after the crystal violet stain has faded under violet or near-UV light.

  8. Phenomenological vessel burst investigations

    International Nuclear Information System (INIS)

    Hippelein, K.W.; Julisch, P.; Muz, J.; Schiedermaier, J.

    1985-07-01

    Fourteen burst experiments have been carried out using vessels with circumferential and longitudinal flaws, for investigation of the fracture behaviour, i.e. the time-related fracture opening. The vessels had dimensions (outer diameter x wall thickness = 800 x 47 mm) which correspond to the dimensions of the main coolant piping of a 1300 MW e PWR. The test specimens had been made of the base-safe material 20 MnMoNi 55 and of a special, 22 NiMoCr 37 base alloy. The experimental conditions with regard to pressure and temperature have been chosen so as to correspond to normal operating conditions of a PWR (p∝17.5 MPa, T∝300 0 C), i.e. the flaws have been so dimensioned that failure was to be expected at a pressure of p∝17.5 MPa. As a rule, water has been used as the pressure medium, or in some cases air, in order to influence the time-dependent pressure decrease. Fluid and structural dynamics calculations have also been made. In order to determine the impact of a fast propagating crack on the leak-to-fracture curve, which normally is defined by quasistationary experiments, suitable tests have been made with large-volume, cylindrical vessels (outer diameter x wall thickness x length = 3000 x 21 x 14000 mm) made of the material WSt E 43. The leak-before-fracture criterion has been confirmed. (orig./HP) [de

  9. Blood Vessels in Allotransplantation.

    Science.gov (United States)

    Abrahimi, P; Liu, R; Pober, J S

    2015-07-01

    Human vascularized allografts are perfused through blood vessels composed of cells (endothelium, pericytes, and smooth muscle cells) that remain largely of graft origin and are thus subject to host alloimmune responses. Graft vessels must be healthy to maintain homeostatic functions including control of perfusion, maintenance of permselectivity, prevention of thrombosis, and participation in immune surveillance. Vascular cell injury can cause dysfunction that interferes with these processes. Graft vascular cells can be activated by mediators of innate and adaptive immunity to participate in graft inflammation contributing to both ischemia/reperfusion injury and allograft rejection. Different forms of rejection may affect graft vessels in different ways, ranging from thrombosis and neutrophilic inflammation in hyperacute rejection, to endothelialitis/intimal arteritis and fibrinoid necrosis in acute cell-mediated or antibody-mediated rejection, respectively, and to diffuse luminal stenosis in chronic rejection. While some current therapies targeting the host immune system do affect graft vascular cells, direct targeting of the graft vasculature may create new opportunities for preventing allograft injury and loss. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  10. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomenology of radiation-induced changes in blood vessels are systematized and authors' experience is generalized. Modern concepts about processes leading to vessel structure injury after irradiation is critically analyzed. Special attention is paid to reparation and compensation of X-ray vessel injury, consideration of which is not yet sufficiently elucidated in literature

  11. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomeology of radiation changes of blood vessels are systemized and the authors' experience is generalyzed. A critical analysis of modern conceptions on processes resulting in vessel structure damage after irradiation, is given. Special attention is paid to reparation and compensation of radiation injury of vessels

  12. Fluorescent Staining of Tea Pathogenic Fungi in Tea Leaves Using Fluorescein-labeled Lectin

    Science.gov (United States)

    Yamada, Kengo; Yoshida, Katsuyuki; Sonoda, Ryoichi

    Fluorochrome-labeled lectin, fluorescein conjugated wheat germ agglutinin (F-WGA) was applied to stain tea pathogenic fungi in tea leaf tissue. Infected leaves were fixed and decolorized with a mixture of ethanol and acetic acid, and cleared with 10% KOH for whole mount before staining with F-WGA. Hyphae of Pestalotiopsis longiseta, Pseudocercospora ocellata, Botrytis cinerea and Colletotrichum theae-sinensis fluoresced brightly in whole mount and sectioned samples of infected leaf tissue. In browned tissue, hyphae did not fluoresce frequently in whole mount sample. Autofluorescence of leaf tissue was strong in browned tissue of sections, it was removed by 10% KOH treatment before staining. Penetration hyphae of C. theae-sinensis in cell wall of trichome and hyphae in basal part of trichome did not fluoresced frequently. In whole mount samples of tea leaf infected with Exobasidium vexans and E. reticulatum, hymenia appeared on leaf surface fluoresced, but hyphae in leaf tissue did not fluoresce. In sectioned samples, hyphae fluoresced brightly when sections were treated with 10% KOH before staining.

  13. Quantitative gel electrophoresis: new records in precision by elaborated staining and detection protocols.

    Science.gov (United States)

    Deng, Xi; Schröder, Simone; Redweik, Sabine; Wätzig, Hermann

    2011-06-01

    Gel electrophoresis (GE) is a very common analytical technique for proteome research and protein analysis. Despite being developed decades ago, there is still a considerable need to improve its precision. Using the fluorescence of Colloidal Coomassie Blue -stained proteins in near-infrared (NIR), the major error source caused by the unpredictable background staining is strongly reduced. This result was generalized for various types of detectors. Since GE is a multi-step procedure, standardization of every single step is required. After detailed analysis of all steps, the staining and destaining were identified as the major source of the remaining variation. By employing standardized protocols, pooled percent relative standard deviations of 1.2-3.1% for band intensities were achieved for one-dimensional separations in repetitive experiments. The analysis of variance suggests that the same batch of staining solution should be used for gels of one experimental series to minimize day-to-day variation and to obtain high precision. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Effect of Melamine Sponge on Tooth Stain Removal.

    Science.gov (United States)

    Otsuka, Takero; Kawata, Toshitsugu

    2015-01-01

    To investigate the stain removal ability of melamine sponge before aesthetic tooth whitening in extracted teeth. Melamine sponge of thickness 40 mm was compressed and the destruction of the partition wall structure during the compression process was examined under a stereoscopic microscope. An extracted human tooth was cleaned by normal polishing or with melamine sponge for 90 s. To evaluate the stain level, the tooth surfaces were photographed under a stereoscopic microscope at 0, 30, 60 and 90 s. The residual stained region was traced in a high-magnification photograph, and the stain intensity was presented as a change, relative to the intensity before the experiment (0 s). Mechanical cleaning by toothbrushing produced polishing scratches on the tooth surface, whereas use of the melamine sponge resulted in only minimal scratches. As the compression level increased, the stain-removing effect tended to become stronger. Melamine sponge can remove stains from the tooth surface more effectively and less invasively compared to a conventional toothbrush. As no new scratches are made on the tooth surface when using a melamine sponge brush, the risk of re-staining is reduced. Cleaning using a melamine sponge brush can be easily and effectively performed at home and in a dental office.

  15. Western Blot of Stained Proteins from Dried Polyacrylamide Gels

    Science.gov (United States)

    Gruber, Claudia; Stan-Lotter, Helga

    1996-01-01

    Western blotting of proteins is customarily performed following their separation on polyacrylamide gels, either prior to staining (1) or, as recently reported, following staining (2). We describe here Western blotting with stained gels, which had been dried and some of which had been stored for years. This procedure permits immunological analysis of proteins, to which antisera may have become available only later, or where the application of newly developed sensitive detection methods is desired. Once rehydration of the gels is achieved, proteins can be-transferred to blotting membranes by any appropriate protocol. Proteins stained with Coomassie Blue have to be detected with a non-chromogenic method, such as the film-based enhanced chemiluminescence (ECL)2) procedure (3). Silver stained proteins, which transfer in the colorless form, may be visualized by any detection method, although, because of the usually very low amounts of proteins, detection by ECL is preferable. Blotting of stained proteins from rehydrated gels is as rapid and as quantitative as from freshly prepared gels, in contrast to blotting from wet stained gels, which requires extensive washing and results in low transfer efficiency (2). Together with a photographic record of the gel pattern, unambiguous identification of immunoreactive proteins from complex mixtures is possible. Some further applications of this work are discussed.

  16. [Usefulness of sputum Gram staining in community-acquired pneumonia].

    Science.gov (United States)

    Sato, Tadashi; Aoshima, Masahiro; Ohmagari, Norio; Tada, Hiroshi; Chohnabayashi, Naohiko

    2002-07-01

    To evaluate the usefulness of sputum gram staining in community-acquired pneumonia (CAP), we reviewed 144 cases requiring hospitalization in the last 4 years. The sensitivity was 75.5%, specificity 68.2%, positive predictive value 74.1%, negative predictive value 69.8%, positive likelihood ratio 2.37, negative likelihood ratio 0.36 and accuracy 72.2% in 97 cases. Both sputum gram staining and culture were performed. Concerning bacterial pneumonia (65 cases), we compared the Gram staining group (n = 33), which received initial antibiotic treatment, based on sputum gram staining with the Empiric group (n = 32) that received antibiotics empirically. The success rates of the initial antibiotic treatment were 87.9% vs. 78.1% (P = 0.473); mean hospitalization periods were 9.67 vs. 11.75 days (P = 0.053); and periods of intravenous therapy were 6.73 vs. 7.91 days (P = 0.044), respectively. As for initial treatment, penicillins were used in the Gram staining group more frequently (P gram staining is useful for the shortening of the treatment period and the appropriate selection of initial antibiotics in bacterial pneumonia. We believe, therefore, that sputum gram staining is indispensable as a diagnostic tool CAP.

  17. Improved method for combination of immunocytochemistry and Nissl staining.

    Science.gov (United States)

    Kádár, Andrea; Wittmann, Gábor; Liposits, Zsolt; Fekete, Csaba

    2009-10-30

    Nissl staining is a widely used method to study morphology and pathology of neural tissue. After standard immunocytochemistry, the Nissl staining labels only the nucleus of neurons and the characteristic staining of the neuronal perikarya is absent or very weak. We hypothesized that the RNA degradation during the immunocytochemical treatment results in the loss of cytoplasmic staining with Nissl-dyes. To test this hypothesis, we used RNAse-free conditions for all steps of immunostaining. To further prevent the RNA-degradation by RNAse contaminations, the RNAse inhibitor heparin was added to all antibody-containing solutions. The efficiency of Nissl staining after standard and RNAse-free double-labeling immunocytochemistry was compared using antibodies against c-Fos and neuropeptide Y (NPY) on tissues of rats refed after 3 days of fasting. After standard immunocytochemistry, the Nissl-staining labeled the nuclei of neurons and only very faintly the cytoplasm of these cells. The RNAse-free treatment did not alter the distribution of immunoreaction signal, but preserved the staining of neuronal perikarya by the Nissl-dyes. In conclusion, the RNAse-free conditions during immunocytochemistry allow the labeling of neuronal perikarya by Nissl-dyes. The described method facilitates the mapping of immunocytochemical signals and makes possible the light microscopic examination of the innervation of neurons identified by their nuclear protein content.

  18. LANTHANUM STAINING OF THE SURFACE COAT OF CELLS

    Science.gov (United States)

    Shea, Stephen M.

    1971-01-01

    Among the techniques which have been reported to stain the surface coat of cells, for electron microscopy, is lanthanum staining en bloc. Similarly, the presence of the cationic dye, Alcian blue 8GX, in a primary glutaraldehyde fixative has been reported to improve the preservation of the surface coat of cells of many types; however, the preserved coat is not very electron opaque unless thin sections are counterstained. The present paper shows that for several rat tissues lanthanum staining en bloc is an effective electron stain for the cell surface, giving excellent contrast, if combined sequentially with prefixation in an aldehyde fixative containing Alcian blue. The cationic substance cetylpyridinium chloride was found to have a similar effect to that of Alcian blue in enhancing the lanthanum staining of the surface coat material of the brush border of intestinal epithelial cells. The patterns of lanthanum staining obtained for the tissues studied strikingly resemble those reported in the literature where tissues are stained by several standard methods for demonstrating mucosubstances at the ultrastructural level. This fact and the reproduction of the effect of Alcian blue by cetylpyridinium chloride constitute a persuasive empirical argument that the material visualized is a mucopolysaccharide or mucopolysaccharide-protein complex. PMID:4108476

  19. Silver and Cyanine Staining of Oligonucleotides in Polyacrylamide Gel.

    Science.gov (United States)

    Tang, Weizhong; Zhou, Huafu; Li, Wei

    2015-01-01

    To explore why some oligonucleotides in denaturing polyacrylamide gel could not be silver-stained, 134 different oligonucleotides were analyzed using denaturing polyacrylamide gel electrophoresis stained with silver and asymmetric cyanine. As a result, we found that the sensitivity of oligos (dA), (dC), (dG) and (dT) to silver staining could be ranged as (dA) > (dG) > (dC) > (dT) from high to low. It was unexpected that oligo (dT) was hard to be silver-stained. Moreover, the silver staining of an oligonucleotide containing base T could be partially or completely inhibited by base T. The inhibition of silver staining by base T was a competitive inhibition which could be affected by the amounts of the argyrophil nucleobase and base T, the cis-distance between the argyrophil nucleobase and base T, and the gel concentration. The changes of the intensity of an oligonucleotide band caused by the changes of DNA base composition were diverse and interesting. The intensity of some oligonucleotide bands would significantly change when the changes of DNA base composition accumulated to a certain extent (usually ≥ 4 nt). The sensitivity of cyanine staining of ≤ 11-nt long oligonucleotides could be enhanced about 250-fold by fixing the gels with methanol fixing solution.

  20. A novel washing algorithm for underarm stain removal

    Science.gov (United States)

    Acikgoz Tufan, H.; Gocek, I.; Sahin, U. K.; Erdem, I.

    2017-10-01

    After contacting with human sweat which comprise around 27% sebum, anti-perspirants comprising aluminium chloride or its compounds form a jel-like structure whose solubility in water is very poor. In daily use, this jel-like structure closes sweat pores and hinders wetting of skin by sweat. However, when in contact with garments, they form yellowish stains at the underarm of the garments. These stains are very hard to remove with regular machine washing. In this study, first of all, we focused on understanding and simulating such stain formation on the garments. Two alternative procedures are offered to form jel-like structures. On both procedures, commercially available spray or deo-stick type anti-perspirants, standard acidic and basic sweat solutions and artificial sebum are used to form jel-like structures, and they are applied on fabric in order to get hard stains. Secondly, after simulation of the stain on the fabric, we put our efforts on developing a washing algorithm specifically designed for removal of underarm stains. Eight alternative washing algorithms are offered with varying washing temperature, amounts of detergent, and pre-stain removal procedures. Better algorithm is selected by comparison of Tristimulus Y values after washing.

  1. Van Gieson's picrofuchsin. The staining mechanisms for collagen and cytoplasm, and an examination of the dye diffusion rate model of differential staining

    DEFF Research Database (Denmark)

    Prentø, P

    1993-01-01

    this and experiments with additives (sodium dodecylsulphate, urea etc.) and organic solvents, it is proposed that coagulant interchain cross-linking at the high protein concentration of the cytoplasm masks potential dye-binding sites. This affects high affinity dyes with multiple binding sites more than small dyes......, and so puts AcF at a disadvantage compared to PA. Staining of non-collagen proteins is mainly by hydrophobic bonding, involving ionic attractions, apolar bonds, and release of water. This mode of binding is relatively strong, decreases swelling and leads to slow dye exchange. Dye binding to collagen...

  2. Testing strong interaction theories

    International Nuclear Information System (INIS)

    Ellis, J.

    1979-01-01

    The author discusses possible tests of the current theories of the strong interaction, in particular, quantum chromodynamics. High energy e + e - interactions should provide an excellent means of studying the strong force. (W.D.L.)

  3. Standardization in biological staining. The influence of dye manufacturing

    DEFF Research Database (Denmark)

    Lyon, H

    2000-01-01

    not have been subjected to quality assessment either internally by the producer or vendor or externally by independent investigators or organizations such as the Biological Stain Commission. Concerted attempts at standardization in Europe are discussed. The latest results of this work, the European...... standard EN 12376, is presented. This standard is concerned with information supplied by the manufacturer with in vitro diagnostic reagents for biological staining. The standard has been prepared by a Working Group on Staining in Biology under Technical Committee 140, In Vitro Medical Devices...

  4. A new technique for Gram staining paraffin-embedded tissue.

    Science.gov (United States)

    Engbaek, K; Johansen, K S; Jensen, M E

    1979-01-01

    Five techniques for Gram staining bacteria in paraffin sections were compared on serial sections of pulmonary tissues from eight bacteriological necropsies. Brown and Hopp's method was the most satisfactory for distinguishing Gram-positive and Gram-negative bacteria. However, this method cannot be recommended as the preparations were frequently overstained, and the Gram-negative bacteria were stained indistinctly. A modification of Brown and Hopps' method was developed which stains larger numbers of Gram-negative bacteria and differentiates well between different cell types and connective tissue, and there is no risk of overstaining. PMID:86548

  5. Eddy current testing of composite pressure vessels

    Science.gov (United States)

    Casperson, R.; Pohl, R.; Munzke, D.; Becker, B.; Pelkner, M.

    2018-04-01

    The use of composite pressure vessels instead of conventional vessels made of steel or aluminum grew strongly over the last decade. The reason for this trend is the tremendous weight saving in the case of composite vessels. However, the long-time behavior is not fully understood for filling and discharging cycles and creep strength and their influence on the CFRP coating (carbon fiber reinforced plastics) and the internal liner (steel, aluminum, or plastics). The CFRP ensures the pressure resistance while the inner liner is used as a container for liquid or gas. To overcome the missing knowledge of aging, BAM started an internal project to investigate degradation of these material systems. Therefore, applicable testing methods like eddy current testing are needed. Normally, high-frequency eddy current testing (HF-ET, f > 10 MHz) is deployed for CFRP due to its low conductivity of the fiber, which is in the order of 0.01 MS/s, and the capacitive coupling between the fibers. Nevertheless, in some cases conventional ET can be applied. We show a concise summary of studies on the application of conventional ET of composite pressure vessels.

  6. Pressure vessel lid

    International Nuclear Information System (INIS)

    Schoening, J.; Elter, C.; Becker, G.; Pertiller, S.

    1986-01-01

    The invention concerns a lid for closing openings in reactor pressure vessels containing helium, which is made as a circular casting with hollow spaces and a flat floor and is set on the opening and kept down. It consists of helium-tight metal cast material with sufficient temperature resistance. There are at least two concentric heat resistant seals let into the bottom of the lid. The bottom is in immediate contact with the container atmosphere and has hollow spaces in its inside in the area opposite to the opening. (orig./HP) [de

  7. [Small vessel cerebrovascular disease].

    Science.gov (United States)

    Cardona Portela, P; Escrig Avellaneda, A

    2018-05-09

    Small vessel vascular disease is a spectrum of different conditions that includes lacunar infarction, alteration of deep white matter, or microbleeds. Hypertension is the main risk factor, although the atherothrombotic lesion may be present, particularly in large-sized lacunar infarctions along with other vascular risk factors. MRI findings are characteristic and the lesions authentic biomarkers that allow differentiating the value of risk factors and defining their prognostic value. Copyright © 2018 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Kinetics of bacterial fluorescence staining with 3,3'-diethylthiacyanine.

    Science.gov (United States)

    Thomas, Marlon S; Nuñez, Vicente; Upadhyayula, Srigokul; Zielins, Elizabeth R; Bao, Duoduo; Vasquez, Jacob M; Bahmani, Baharak; Vullev, Valentine I

    2010-06-15

    For more than a century, colorimetric and fluorescence staining have been the foundation of a broad range of key bioanalytical techniques. The dynamics of such staining processes, however, still remains largely unexplored. We investigated the kinetics of fluorescence staining of two gram-negative and two gram-positive species with 3,3'-diethylthiacyanine (THIA) iodide. An increase in the THIA fluorescence quantum yield, induced by the bacterial dye uptake, was the principal reason for the observed emission enhancement. The fluorescence quantum yield of THIA depended on the media viscosity and not on the media polarity, which suggested that the microenvironment of the dye molecules taken up by the cells was restrictive. The kinetics of fluorescence staining did not manifest a statistically significant dependence neither on the dye concentration, nor on the cell count. In the presence of surfactant additives, however, the fluorescence-enhancement kinetic patterns manifested species specificity with statistically significant discernibility.

  9. Acetylcholinesterase and Nissl staining in the same histological section.

    Science.gov (United States)

    Shipley, M T; Ennis, M; Behbehani, M M

    1989-12-18

    Acetylcholinesterase (AChE) enzyme histochemistry and Nissl staining are commonly utilized in neural architectonic studies. However, the opaque reaction deposit produced by the most commonly used AChE histochemical methods is not compatible with satisfactory Nissl staining. As a result, precise correlation of AChE and Nissl staining necessitates time-consuming comparisons of adjacent sections which may have differential shrinkage. Here, we have modified the Koelle-Friedenwald histochemical reaction for AChE by omitting the final intensification steps. The modified reaction yields a non-opaque reaction product that is selectively visualized by darkfield illumination. This non-intensified darkfield AChE (NIDA) reaction allows clear visualization of Nissl staining in the same histological section. This combined AChE-Nissl method greatly facilitates detailed correlation of enzyme and cytoarchitectonic organization.

  10. Microscopic analysis of MTT stained boar sperm cells

    African Journals Online (AJOL)

    tulyasys

    2015-06-08

    2H-tetrazolium bromide is widely used for assessment of cytotoxicity, cell viability, and proliferation studies in cell biology (van Meerloo et al., 2011;. Stockert et al., 2012). The stain is abbreviated as MTT.

  11. Simulating light transport through skin for color prediction of port wine stain lesions: a review

    Science.gov (United States)

    Lister, Tom; Wright, Philip A.; Chappell, Paul H.

    2012-11-01

    A survey of the literature is presented regarding the simulation of port wine stain (PWS) skin color. Knowledge of PWS features, such as the depths and diameters of affected vessels, is essential for informing laser treatment. These may be determined through the inverse application of a skin model. The techniques which have been applied to achieve this are analyzed in detail. Radiative transfer (RT) is found to be the preferred method of simulation. By far the most common approximations to RT are the diffusion approximations, which have been applied successfully in the past and Monte Carlo techniques, which are now the methods of choice. As the requirements for improvement of laser treatment on an individual basis continues, the needs for further work towards accurate estimations of individual optical coefficients and robust, flexible simulation techniques are identified.

  12. Establishment of an animal model of mice with radiation- injured soft tissue blood vessels

    International Nuclear Information System (INIS)

    Wang Daiyou; Yu Dahai; Wu Jiaxiao; Wei Shanliang; Wen Yuming

    2004-01-01

    Objective: The aim of this study was to establish an animal model of mice with radiation-injured soft tissue blood vessels. Methods: Forty male mice were irradiated with 30 Gy on the right leg. After the irradiation was finished each of the 40 male mice was tested with angiography, and its muscle tissues on the bilateral legs were examined with vessel staining assay and electron microscopy. Results: The results showed that the number of vessels on the right leg was less than that on the left leg, the microvessel density, average diameter and average sectional area of the right leg were all lower than those of the left, and the configuration and ultra-structure of vessels were also different between both sides of legs. Conclusion: In the study authors successfully established an animal model of mice with radiation-injured soft tissue blood vessels

  13. Measurement of neuron soma size by fluorescent Nissl stain

    OpenAIRE

    sprotocols

    2015-01-01

    Authors: James Cronk, Noel Derecki & Jonathan Kipnis ### Abstract This protocol describes how to measure neuron soma size by fluorescent Nissl stain. Mice are sacrificed, and fixed by PFA perfusion. Brains are removed, and further PFA fixed, followed by sucrose cryoprotection. They are then snap frozen, sliced by cryostat, and stained with fluorescent Nissl as floating sections. Confocal microscopy is used to take images of neurons, and a computer graphics tablet is used to calculate ...

  14. TPX vacuum vessel transient thermal and stress conditions

    International Nuclear Information System (INIS)

    Feldshteyn, Y.; Dinkevich, S.; Feng, T.; Majumder, D.

    1995-01-01

    The TPX vacuum vessel provides the vacuum boundary for the plasma and the mechanical support for the internal components. Another function of the vacuum vessel is to contain neutron shielding water in the double wall space during normal operation. This double wall space serves as a heat reservoir for the entire vacuum vessel during bakeout. The vacuum vessel and the internal components are subjected to thermal stresses induced by a nonuniform temperature distribution within the structure during bakeout. A successful Conceptual Design Review in March 1993 has established superheated steam as the heating source of the vacuum vessel. A transient bakeout mode of the vacuum vessel and in-vessel components has been analyzed to evaluate transient period duration, proper temperature level, actual thermal stresses and performance of the steam equipment. Thermally, the vacuum vessel structure may be considered as an adiabatic system because it is perfectly insulated by the strong surrounding vacuum and multiple layers of superinsulation. Important aspects of the analysis are described herein

  15. Gram staining for the treatment of peritonsillar abscess.

    Science.gov (United States)

    Takenaka, Yukinori; Takeda, Kazuya; Yoshii, Tadashi; Hashimoto, Michiko; Inohara, Hidenori

    2012-01-01

    Objective. To examine whether Gram staining can influence the choice of antibiotic for the treatment of peritonsillar abscess. Methods. Between 2005 and 2009, a total of 57 cases of peritonsillar abscess were analyzed with regard to cultured bacteria and Gram staining. Results. Only aerobes were cultured in 16% of cases, and only anaerobes were cultured in 51% of cases. Mixed growth of aerobes and anaerobes was observed in 21% of cases. The cultured bacteria were mainly aerobic Streptococcus, anaerobic Gram-positive cocci, and anaerobic Gram-negative rods. Phagocytosis of bacteria on Gram staining was observed in 9 cases. The bacteria cultured from these cases were aerobic Streptococcus, anaerobic Gram-positive cocci, and anaerobic Gram-negative rods. The sensitivity of Gram staining for the Gram-positive cocci and Gram-negative rods was 90% and 64%, respectively. The specificity of Gram staining for the Gram-positive cocci and Gram-negative rods was 62% and 76%, respectively. Most of the Gram-positive cocci were sensitive to penicillin, but some of anaerobic Gram-negative rods were resistant to penicillin. Conclusion. When Gram staining shows only Gram-positive cocci, penicillin is the treatment of choice. In other cases, antibiotics effective for the penicillin-resistant organisms should be used.

  16. An improved method for staining cell colonies in clonogenic assays.

    Science.gov (United States)

    Guda, Kishore; Natale, Leanna; Markowitz, Sanford D

    2007-06-01

    Clonogenic assay is a widely used experimental approach to test for the effects of drugs/genes on the growth and proliferative characteristics of cells in vitro. Accurate quantitation of treatment effects in clonogeneic assays depends on the ability to visualize and count cell colonies precisely. We report a novel method (referred as ETeB) for staining cell colonies grown on plastic and specially coated substrates like collagen. Using colon cancer cell lines grown on plastic and collagen, we compared the colony staining efficiencies of the widely used methylene blue, and Ethidium bromide (ETeB) stains. Results show that the ETeB protocol works well on plastic and is extremely effective for staining colonies on collagen when compared to methylene blue. The key features and advantages of ETeB technique are; (a) reduction in background for colonies grown on collagen and possibly other substrates, (b) the whole procedure takes less than a minute, (c) no post-stain washing step is required which eliminates colony losses for cell lines that are loosely adherent, (d) colony visualization and counting can be done immediately following the staining procedure using a standard UV illuminator and software, and (e) the method works across a wide variety of cell lines. The simplicity and robustness of this procedure should warrant its usage in both small and large-scale clonogenic experiments.

  17. MANAJEMEN SARANA DAN PRASARANA PENDIDIKAN DI STAIN PAMEKASAN

    Directory of Open Access Journals (Sweden)

    M. Muchlis Solichin

    2011-07-01

    Full Text Available Mediums management and pre-mediums represent an absolute done in an higher education institute, because Mediums and premediums in education management represent the absolut condition in the effort to reach the target which is expected. Thereby, Every the education organizer have to pay attention and conscripting the mind and energy to carry out education management that is professional and fulfill Standard National Education ( SNP. This Research copes to comprehend the mediums and pre-mediums management of education in STAIN Pamekasan, because during this time of mediums and basic mediums management are not yet showing its idealitas. This research is focussed at; a How mediums and pre-mediums menegement in STAIN Pamekasan ?,and b what Factors influencing mediums and pre-mediums management in STAIN Pamekasan ?. This research uses the qualitative type by using observation, interview, and documentation method. Based the rearch done, to be expressed that the first of STAIN Pamekasan conduct mediums and pre-mediums manegement still have the centralization character of top down, either in the case of planning, organizational, observation, and assessment of mediums and pre-mediums management owned, second in some cases of STAIN Pamekasan do not yet manage the mediums and pre-mediums management because they are caused by factor is its lack of management professionalism, either when doing the planning, organizational, treatment and observation or evaluation. Based the matter above, hence, suggested that STAIN Pamekasan carry out the mediums and pre-mediums management of education professionally.

  18. Design and synthesis of new fluorescent probe for rapid and highly sensitive detection of proteins via electrophoretic gel stain.

    Science.gov (United States)

    Suzuki, Yoshio; Takagi, Nobuyuki; Chimuro, Tomoyuki; Shinohara, Atsushi; Sakaguchi, Nao; Hiratsuka, Atsunori; Yokoyama, Kenji

    2011-06-01

    A new fluorescent molecular probe, 2,2'-(1E,1'E)-2,2'-(4-(dicyanomethylene)-4H-pyrane-2,6-diyl)bis(ethene-2,1-diyl)bis(sodium benzenesulfonate) salt (1), possessing the cyanopyranyl moieties and two benzene sulfonic acid groups was designed and synthesized to detect proteins in solution and for high-throughput SDS-PAGE. Compound 1 exhibited no fluorescence in the absence of proteins; however, it exhibited strong fluorescence on the addition of bovine serum albumin as a result of intramolecular charge transfer. Compared with the conventional protocols for in-gel protein staining, such as SYPRO Ruby and silver staining, 1 achieves higher sensitivity, even though it offers a simplified, higher throughput protocol. In fact, the total time required for protein staining was 60-90 min under optimum conditions much shorter than that required by the less-sensitive silver staining or SYPRO Ruby staining protocols. Moreover, 1 was successfully applied to protein identification by mass spectrometry via in-gel tryptic digestion, Western blotting, and native PAGE together with protein staining by 1, which is a modified protocol of blue native PAGE (BN-PAGE). Thus, 1 may facilitate high-sensitivity protein detection, and it may be widely applicable as a convenient tool in various scientific and medical fields. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Diagnostic value of the digital subtraction angiography of brain tumors. With special reference to the significance of tumor stains

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Yoshifumi; Matsukado, Yasuhiko; Takahashi, Mutsumasa

    1986-10-01

    Digital subtraction angiography (DSA) in 110 cases of brain tumors were studied in comparison with conventional angiography (CA). The dural sinuses and tumor stains of meningiomas, particularly tuberculum sellae meningioma, were better shown by intravenous DSA (IV-DSA) than by CA. IV-DSA clearly demonstrated bilateral carotid arteries and was able to rule out the coexistence of the intracranial aneurysm in 88 % of 32 cases with pituitary adenomas. Combination of IV-DSA and high resolution computed tomography has replaced CA to determine surgical indication of patients with pituitary adenomas. Intra-arterial DSA (IA-DSA) was diagnostic and well comparable to CA in identifying main cerebral vasculature over 1 mm in diameter. As to the small arteries under 1 mm and fine tumor vessels, IA-DSA provided less information or none at all. However, IA-DSA was superior to CA for visualization of tumor stains. Not only in most of meningiomas and hemangioblastomas, but in some astrocytomas and oligodendrogliomas, marked tumor stains were well demonstrated on DSA, and DSA provided surgical anatomy for neurosurgeons because of high contrast resolutions. Careful attention should be paid because tumor stains may overestimate tumor vascularity.

  20. An automated vessel segmentation of retinal images using multiscale vesselness

    International Nuclear Information System (INIS)

    Ben Abdallah, M.; Malek, J.; Tourki, R.; Krissian, K.

    2011-01-01

    The ocular fundus image can provide information on pathological changes caused by local ocular diseases and early signs of certain systemic diseases, such as diabetes and hypertension. Automated analysis and interpretation of fundus images has become a necessary and important diagnostic procedure in ophthalmology. The extraction of blood vessels from retinal images is an important and challenging task in medical analysis and diagnosis. In this paper, we introduce an implementation of the anisotropic diffusion which allows reducing the noise and better preserving small structures like vessels in 2D images. A vessel detection filter, based on a multi-scale vesselness function, is then applied to enhance vascular structures.

  1. A case of perforated sigmoid diverticulitis in which gram staining of ascitic fluid was useful for diagnosis.

    Science.gov (United States)

    Tsuchida, Junko; Fujita, Shouhei; Kawano, Fumihiro; Tsukamoto, Ryoichi; Honjo, Kunpei; Naito, Shigetoshi; Ishiyama, Shun; Miyano, Shozo; Machida, Michio; Kitabatake, Toshiaki; Fujisawa, Minoru; Kojima, Kuniaki; Ogura, Kanako; Matsumoto, Toshiharu

    2014-01-01

    An 85-year-old woman was admitted to our hospital for steroid therapy for relapsing nephrotic syndrome. During hospitalization, she complained of sudden epigastric pain at night. Although there were signs of peritoneal irritation, CT showed a large amount of ascitic fluid, but no free intraperitoneal gas. Gram staining of ascitic fluid obtained by abdominal paracentesis showed Gram-negative rods, which raised a strong suspicion of gastrointestinal perforation and peritonitis. Therefore, emergency surgery was performed. Exploration of the colon showed multiple sigmoid diverticula, one of which was perforated. The patient underwent an emergency Hartmann's procedure. Imaging studies failed to reveal any evidence of gastrointestinal perforation, presenting a diagnostic challenge. However, a physician performed rapid Gram staining of ascitic fluid at night when laboratory technicians were absent, had a strong suspicion of gastrointestinal perforation, and performed emergency surgery. Gram staining is superior in rapidity, and ascitic fluid Gram staining can aid in diagnosis, suggesting that it should be actively performed. We report this case, with a review of the literature on the significance of rapid diagnosis by Gram staining.

  2. Determination of ABO blood grouping from human oral squamous epithelium by the highly sensitive immunohistochemical staining method EnVision+.

    Science.gov (United States)

    Noda, Hiroshi; Yokota, Makoto; Tatsumi, Shinji; Sugiyama, Shizuyuki

    2002-03-01

    Using the highly sensitive immunohistochemical staining method EnVision+, which employs a dextran polymer reagent for the secondary antibody, the detection of the ABH antigens was attempted in the oral squamous epithelium. This new technique uses monoclonal antibody as a primary antibody and it takes about three hours for staining. The time is much shorter than conventional absorption-elution testing or absorption-inhibition testing for the determination of ABO blood grouping. Secretor saliva samples were stained at strong intensity by the antibody, which corresponded to its blood group and anti-H. On the one hand, nonsecretor saliva samples were stained at strong intensity only by the antibody that corresponded to its blood group, and at weak intensity only by anti-H. Since human oral squamous epithelium antigens were stained specifically by this method, we can examine the ABO blood group of saliva samples and perform cytodiagnosis at the same time. Our research suggested that the EnVision+ Method is a useful technique for ABO blood grouping of saliva in forensic cases.

  3. Targeting Therapy Resistant Tumor Vessels

    Science.gov (United States)

    2008-08-01

    Morris LS. Hysterectomy vs. resectoscopic endometrial ablation for the control of abnormal uterine bleeding . A cost-comparative study. J Reprod Med 1994;39...after the antibody treatment contain a pericyte coat, vessel architecture is normal, the diameter of the vessels is smaller (dilated, abnormal vessels...involvement of proteases from inflammatory mast cells and functionally abnormal (Carmeliet and Jain, 2000; Pasqualini (Coussens et al., 1999) and other bone

  4. The vessel fluence; Fluence cuve

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This book presents the proceedings of the technical meeting on the reactors vessels fluence. They are grouped in eight sessions: the industrial context and the stakes of the vessels control; the organization and the methodology for the fluence computation; the concerned physical properties; the reference computation methods; the fluence monitoring in an industrial context; vessels monitoring under irradiation; others methods in the world; the research and development programs. (A.L.B.)

  5. Abortion: Strong's counterexamples fail

    DEFF Research Database (Denmark)

    Di Nucci, Ezio

    2009-01-01

    This paper shows that the counterexamples proposed by Strong in 2008 in the Journal of Medical Ethics to Marquis's argument against abortion fail. Strong's basic idea is that there are cases--for example, terminally ill patients--where killing an adult human being is prima facie seriously morally...

  6. Strong Langmuir turbulence

    International Nuclear Information System (INIS)

    Goldman, M.V.

    1984-01-01

    After a brief discussion of beam-excited Langmuir turbulence in the solar wind, we explain the criteria for wave-particle, three-wave and strong turbulence interactions. We then present the results of a numerical integration of the Zakharov equations, which describe the strong turbulence saturation of a weak (low-density) high energy, bump-on-tail beam instability. (author)

  7. Americium behaviour in plastic vessels

    International Nuclear Information System (INIS)

    Legarda, F.; Herranz, M.; Idoeta, R.; Abelairas, A.

    2010-01-01

    The adsorption of 241 Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of 241 Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of 241 Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  8. Americium behaviour in plastic vessels

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F.; Herranz, M. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Abelairas, A. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2010-07-15

    The adsorption of {sup 241}Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of {sup 241}Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of {sup 241}Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  9. Americium behaviour in plastic vessels.

    Science.gov (United States)

    Legarda, F; Herranz, M; Idoeta, R; Abelairas, A

    2010-01-01

    The adsorption of (241)Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of (241)Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of (241)Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification. Copyright 2009 Elsevier Ltd. All rights reserved.

  10. [Large vessel vasculitides].

    Science.gov (United States)

    Morović-Vergles, Jadranka; Puksić, Silva; Gracanin, Ana Gudelj

    2013-01-01

    Large vessel vasculitis includes Giant cell arteritis and Takayasu arteritis. Giant cell arteritis is the most common form of vasculitis affect patients aged 50 years or over. The diagnosis should be considered in older patients who present with new onset of headache, visual disturbance, polymyalgia rheumatica and/or fever unknown cause. Glucocorticoides remain the cornerstone of therapy. Takayasu arteritis is a chronic panarteritis of the aorta ant its major branches presenting commonly in young ages. Although all large arteries can be affected, the aorta, subclavian and carotid arteries are most commonly involved. The most common symptoms included upper extremity claudication, hypertension, pain over the carotid arteries (carotidynia), dizziness and visual disturbances. Early diagnosis and treatment has improved the outcome in patients with TA.

  11. Reactor pressure vessel embrittlement

    International Nuclear Information System (INIS)

    1992-07-01

    Within the framework of the IAEA extrabudgetary programme on the Safety of WWER-440/230 NPPs, a list of safety issues requiring broad studies of generic interest have been agreed upon by an Advisory Group who met in Vienna in September 1990. The list was later revised in the light of the programme findings. The information on the status of the issues, and on the amount of work already completed and under way in the various countries, needs to be compiled. Moreover, an evaluation of what further work is required to resolve each one of the issues is also necessary. In view of this, the IAEA has started the preparation of a series of status reports on the various issues. This report on the generic safety issue ''Reactor Pressure Vessel Embrittlement'' presents a comprehensive survey of technical information available in the field and identifies those aspects which require further investigation. 39 refs, 21 figs, 4 tabs

  12. Reactor containment vessel

    International Nuclear Information System (INIS)

    Ochiai, Kanehiro; Hayagumo, Sunao; Morikawa, Matsuo.

    1981-01-01

    Purpose: To safety and simplify the structure in a reactor containment vessel. Constitution: Steam flow channels with steam jetting ports communicating to coolants are provided between a communication channel and coolants in a pressure suppression chamber. Upon loss of coolant accidents, pressure in a dry well will increase, then force downwards water in an annulus portion and further flow out the water through steam jetting ports into a suppression pool. Thus, the steam flow channel is filled with steams or airs present in the dry well, which are released through the steam jetting ports into the pressure suppression chamber. Even though water is violently vibrated owing to the upward movement of air bubbles and condensation of steam bubbles, the annular portion and the steam jetting ports are filled with steams or the like, direct dynamic loads onto the structures such as communication channels can be avoided. (J.P.N.)

  13. Influence of laser wavelength on the thermal responses of port wine stain lesions in light, moderate and heavy pigmented skin

    International Nuclear Information System (INIS)

    Li, D.; Chen, B.; Wu, W.J.; Ying, Z.X.

    2017-01-01

    Highlights: • Laser surgery for port wine stain (PWS) was studied by local non-equilibrium theory. • Wavelength selection in laser surgery under various skin pigmentation was explored. • High pigmented skin prefers to 585 nm rather then 595 nm. • Dual-wavelength laser (585/595 + 1064 nm) has better clinic effect than single one. • Deep buried blood vessels can be damaged by 595/1064 nm dual-wavelength laser. - Abstract: Pulsed dye laser (PDL) in visible band (e.g. 585 or 595 nm) together with cryogen spray cooling has become the golden standard for treatment of vascular malformation such as port wine stain (PWS). However, due to the limited energy penetration depth of the PDL, deeply buried blood vessels are likely to survive from the laser irradiation. Nd:YAG laser in near infrared (1064 nm) has great potential in the laser treatment of PWS due to its deeper penetration depth. In this study, the influence of laser wavelength in treating PWS lesions with various melanin concentrations in epidermis was theoretically investigated by a two-temperature model following the local thermal non-equilibrium theory of porous media. The results showed that deeply buried blood vessels can be coagulated by dual-wavelength laser combing 585 or 595 nm with 1064 nm laser. Furthermore, the therapeutic results by dual-wavelength laser were highly related to the melanin concentration in epidermis. In the light and moderate pigmented skin, the 595/1064 nm dual-wavelength laser showed better treatment effect in treating PWS with deeply-buried blood vessels than of 585/1064 nm dual-wavelength laser. For a high pigmented skin, the 585/1064 nm dual-wavelength laser showed better treatment effect than 595/1064 nm dual-wavelength laser.

  14. Modified Alizarin Red S-Alcian Blue Staining for Reptilian Skeleton

    Directory of Open Access Journals (Sweden)

    Muhammad Ja’far Luthfi

    2016-04-01

    Full Text Available Skeletal staining is an important method in anatomical study. The aim of the research was to develop staining and clearing method of Reptilian skeleton using Alizarin Red S-Alcian Blue. The specimen were eviscerated, fixed, stained, cleared, and keep in glycerine solution. This modified double-staining has successfully stain bone and cartilage of Reptilian.

  15. Self-assembly of highly fluorescent semiconductor nanorods into large scale smectic liquid crystal structures by coffee stain evaporation dynamics

    International Nuclear Information System (INIS)

    Nobile, Concetta; Carbone, Luigi; Fiore, Angela; Cingolani, Roberto; Manna, Liberato; Krahne, Roman

    2009-01-01

    We deposit droplets of nanorods dispersed in solvents on substrate surfaces and let the solvent evaporate. We find that strong contact line pinning leads to dense nanorod deposition inside coffee stain fringes, where we observe large scale lateral ordering of the nanorods with the long axis of the rods oriented parallel to the contact line. We observe birefringence of these coffee stain fringes by polarized microscopy and we find the direction of the extraordinary refractive index parallel to the long axis of the nanorods.

  16. [Intrapartum amnioinfusion in patients with meconium-stained amniotic fluid].

    Science.gov (United States)

    Engel, Karina; Samborska, Monika; Bilar, Marek; Sipak-Szmigiel, Olimpia; Ronin-Walknowska, Elzbieta

    2008-09-01

    The aim of the study was to evaluate the effect of intrapartum amnioinfusion in the presence of meconium stained amniotic fluid. 93 women with meconium-stained amniotic fluid were assigned to receive amnioinfusion or no amnioinfusion (128 women). The trials were evaluated for fetal distress syndrome, route of delivery, fetal acidemia, Apgar score at 1 and 5 min., meconium aspiration syndrome, postpartum endometritis and maternal hospital stays. Amnioinfusion in cases of meconium-stained fluid did not improve the number of fetal distress symptoms during fetal heart rate monitoring. Amnioinfusion was associated with a significant decrease of neonatal acidemia although it did not improve Apgar score. In our study amnioinfusion was not associated with reduction in the incidence of neonatal outcome and puerperial complications.

  17. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    Science.gov (United States)

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  18. MEGARA Optics: stain removal in PBM2Y prisms

    International Nuclear Information System (INIS)

    Aguirre-Aguirre, D; Izazaga-Pérez, R; Carrasco, E; Villalobos-Mendoza, B; De Paz, A Gil; Gallego, J; Iglesias, J

    2017-01-01

    MEGARA is the new integral-field and multi-object optical spectrograph for the GTC. For medium and high resolution, the dispersive elements are volume phase holographic gratings, sandwiched between two flat windows and two prisms of high optical precision. The prisms are made of Ohara PBM2Y optical glass. After the prisms polishing process, some stains appeared on the surfaces. For this, in this work is shown the comparative study of five different products (muriatic acid, paint remover, sodium hydroxide, aqua regia and rare earth liquid polish) used for trying to eliminate the stains of the HR MEGARA prisms. It was found that by polishing with the hands the affected area, and using a towel like a kind of pad, and polish during five minutes using rare earth, the stains disappear completely affecting only a 5% the rms of the surface quality. Not so the use of the other products that did not show any apparent result. (paper)

  19. Chromosome-specific staining to detect genetic rearrangements

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Joe W.; Pinkel, Daniel; Tkachuk, Douglas; Westbrook, Carol

    2013-04-09

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyzes. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  20. ITER vacuum vessel dynamic stress analysis of a disruption

    International Nuclear Information System (INIS)

    Riemer, B.W.; Conner, D.L.; Strickler, D.J.; Williamson, D.E.

    1994-01-01

    Dynamic stress analysis of the International Thermonuclear Experimental Reactor vacuum vessel loaded by disruption forces was performed. The deformation and stress results showed strong inertial effects when compared to static analyses. Maximum stress predicted dynamically was 300 MPa, but stress shown by static analysis from loads at the same point in time reached only 80 MPa. The analysis also provided a reaction load history in the vessel's supports which is essential in evaluating support design. The disruption forces were estimated by assuming a 25-MA plasma current decaying at 1 MA/ms while moving vertically. In addition to forces developed within the vessel, vertical loadings from the first wall/strong back assemblies and the divertor were applied to the vessel at their attachment points. The first 50 natural modes were also determined. The first mode's frequency was 6.0 Hz, and its shape is characterized by vertical displacement of the vessel inner leg. The predicted deformation of the vessel appeared similar to its first mode shape combined with radial contraction. Kinetic energy history from the analysis also correlated with the first mode frequency

  1. Strong intrinsic motivation

    OpenAIRE

    Dessi, Roberta; Rustichini, Aldo

    2015-01-01

    A large literature in psychology, and more recently in economics, has argued that monetary rewards can reduce intrinsic motivation. We investigate whether the negative impact persists when intrinsic motivation is strong, and test this hypothesis experimentally focusing on the motivation to undertake interesting and challenging tasks, informative about individual ability. We find that this type of task can generate strong intrinsic motivation, that is impervious to the effect of monetary incen...

  2. Bitcoin Meets Strong Consistency

    OpenAIRE

    Decker, Christian; Seidel, Jochen; Wattenhofer, Roger

    2014-01-01

    The Bitcoin system only provides eventual consistency. For everyday life, the time to confirm a Bitcoin transaction is prohibitively slow. In this paper we propose a new system, built on the Bitcoin blockchain, which enables strong consistency. Our system, PeerCensus, acts as a certification authority, manages peer identities in a peer-to-peer network, and ultimately enhances Bitcoin and similar systems with strong consistency. Our extensive analysis shows that PeerCensus is in a secure state...

  3. Strong gravity and supersymmetry

    International Nuclear Information System (INIS)

    Chamseddine, Ali H.; Salam, A.; Strathdee, J.

    1977-11-01

    A supersymmetric theory is constructed for a strong f plus a weak g graviton, together with their accompanying massive gravitinos, by gaugin the gradel 0Sp(2,2,1)x 0Sp(2,2,1) structure. The mixing term between f and g fields, which makes the strong graviton massive, can be introduced through a spontaneous symmetry-breaking mechanism implemented in this note by constructing a non-linear realization of the symmetry group

  4. Diagnostic utility of NCOA2 fluorescence in situ hybridization and Stat6 immunohistochemistry staining for soft tissue angiofibroma and morphologically similar fibrovascular tumors.

    Science.gov (United States)

    Sugita, Shintaro; Aoyama, Tomoyuki; Kondo, Kei; Keira, Yoshiko; Ogino, Jiro; Nakanishi, Katsuya; Kaya, Mitsunori; Emori, Makoto; Tsukahara, Tomohide; Nakajima, Hisaya; Takagi, Masayuki; Hasegawa, Tadashi

    2014-08-01

    Soft tissue angiofibroma (STA), a recently suggested new histologic entity, is a benign fibrovascular soft tissue tumor composed of bland spindle-shaped tumor cells with abundant collagenous to myxoid stroma and branching small vessels. The lesion has a characteristic AHRR-NCOA2 fusion gene derived from chromosomal translocation of t(5;8)(p15;q13). However, morphologically similar tumors containing abundant fibrovascular and myxoid stroma can complicate diagnosis. We designed an original DNA probe for detecting NCOA2 split signals on fluorescence in situ hybridization (FISH) and estimated its utility with 20 fibrovascular tumors: 4 each of STAs, solitary fibrous tumors (SFTs), and cellular angiofibromas and 3 each of low-grade myxofibrosarcomas, myxoid liposarcomas, and low-grade fibromyxoid sarcomas. We also performed FISH for 13q14 deletion and immunohistochemistry (IHC) staining for estrogen receptor, progesterone receptor, retinoblastoma protein, and MUC-4 expression. Furthermore, IHC for Stat6 was conducted in the 20 cases analyzed by FISH and in an additional 26 SFTs. We found moderate to strong nuclear Stat6 expression in all SFTs but no expression in the other tumors. Both estrogen receptor and progesterone receptor expressions were observed in STAs, SFTs, and cellular angiofibromas. Expression of retinoblastoma protein was found in less than 10% of cells in all tumor types except myxoid liposarcoma. The low-grade fibromyxoid sarcomas were strongly positive for MUC-4. All STAs showed NCOA2 split signals on FISH. All tumors, regardless of histologic type, had 13q14 deletion. The NCOA2 FISH technique is a practical method for confirming STA diagnosis. The combination of NCOA2 FISH and Stat6 IHC proved effective for the differential diagnosis of STA, even when using small biopsy specimens. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Improvement of malaria diagnostic system based on acridine orange staining.

    Science.gov (United States)

    Kimura, Masatsugu; Teramoto, Isao; Chan, Chim W; Idris, Zulkarnain Md; Kongere, James; Kagaya, Wataru; Kawamoto, Fumihiko; Asada, Ryoko; Isozumi, Rie; Kaneko, Akira

    2018-02-07

    Rapid diagnosis of malaria using acridine orange (AO) staining and a light microscope with a halogen lamp and interference filter was deployed in some malaria-endemic countries. However, it has not been widely adopted because: (1) the lamp was weak as an excitation light and the set-up did not work well under unstable power supply; and, (2) the staining of samples was frequently inconsistent. The halogen lamp was replaced by a low-cost, blue light-emitting diode (LED) lamp. Using a reformulated AO solution, the staining protocol was revised to make use of a concentration gradient instead of uniform staining. To evaluate this new AO diagnostic system, a pilot field study was conducted in the Lake Victoria basin in Kenya. Without staining failure, malaria infection status of about 100 samples was determined on-site per one microscopist per day, using the improved AO diagnostic system. The improved AO diagnosis had both higher overall sensitivity (46.1 vs 38.9%: p = 0.08) and specificity (99.0 vs 96.3%) than the Giemsa method (N = 1018), using PCR diagnosis as the standard. Consistent AO staining of thin blood films and rapid evaluation of malaria parasitaemia with the revised protocol produced superior results relative to the Giemsa method. This AO diagnostic system can be set up easily at low cost using an ordinary light microscope. It may supplement rapid diagnostic tests currently used in clinical settings in malaria-endemic countries, and may be considered as an inexpensive tool for case surveillance in malaria-eliminating countries.

  6. TANTANGAN DAN PELUANG JURUSAN TADRIS DI IAIN/STAIN

    Directory of Open Access Journals (Sweden)

    Mohammad Kosim

    2009-01-01

    Full Text Available A consequence of dualism in education policy, the implementatin of tadris in IAIN often faces many problems. This paper will describe the history and the development of tadris in IAIN/STAIN. The discussion begins with the origin of tadris in IAIN, problems araise in the implementation of tadris in IAIN/STAIN, including the alumni’s problem. In addition, this article also reveals several opportunities for tadris graduation to develop madrasah as purely religious school to public islamic school as the result of the paradigm change.

  7. Fungal Fluorescence in Hematoxylin-Eosin Stained Sections

    Directory of Open Access Journals (Sweden)

    Murat Durdu

    2017-06-01

    Full Text Available A forty-six-year-old male presented to our dermatology clinic with two-year history of itching on his groin. His medical history revealed various topical corticosteroid creams without improvement of the skin lesion. Dermatological examination revealed erythematous nodules and follicular pustules on erythematous background on the inguinal area (Figure 1a. Potassium hydroxide (KOH examination was negative. Tzanck smear revealed abundant neutrophils without bacteria, fungi, or parasite. The histopathological examination showed granuloma formation with multinuclear giant cells and Periodic acid-Schiff (PAS-positive hyphae and spores around the hair follicles (Figure 1b, 1c. Hematoxylin-eosin (H&E-stained slides were examined under an immunofluorescence microscope, and these hyphae and spores showed autofluorescence (Figure 1d. Based on the clinical and histopathological findings, a Majocchi’s granuloma was considered. All lesions disappeared with topical and systemic terbinafine (250 mg/day treatment for six weeks.\tPearls;\tClinical: Not only bacteria, but also fungi, parasites, and viruses may cause folliculitis. Cytology should be initially done to identify the causes of infectious folliculitis. In case of negative cytology, histopathological examination and molecular methods can be used.\tCytological: To cytologically identify all of the causes of folliculitis, four separate samples should be taken: (i the first sample is stained with May-Grünwald-Giemsa for routine cytological examination; (ii the second sample is used for KOH testing; (iii the third sample is stained with an acid-fast stain to detect mycobacteria; and (iv the last specimen is Gram-stained to identify whether it is Gram-positive or Gram-negative (1. Histopathological: In infectious diseases, a definitive diagnosis should be done to identify the etiologic agent. The detection of fungal elements is challenging, when histopathological examination is performed with the H

  8. News from the Biological Stain Commission no. 12

    DEFF Research Database (Denmark)

    Lyon, H O

    2012-01-01

    In this 12(th) issue of News from the Biological Stain Commission (BSC) under the heading of Regulatory affairs, the Biological Stain Commission's International Affairs Committee presents information from the meetings of ISO/TC 212/WG 1 Quality and competence in the medical laboratory and ISO....../TC 212/WG 3 In vitro diagnostic products both held on 2 - 3 June 2010, plus information on the second plenary meeting of ISO/TC 212 Clinical laboratory testing and in vitro diagnostic test systems held on 4 June 2010. All meetings took place in Seoul, Republic of Korea. Finally, information is provided...

  9. Evaluation Method of Accumulated Cooking Oil Stains in Room

    OpenAIRE

    五十嵐, 由利子; 中村, 和吉; 萬羽, 郁子; Igarashi, Yuriko; Nakamura, Kazuyoshi; Banba, Ikuko

    2005-01-01

    The diffusion of the oil mist while cooking affects the entire room, leaving stains on the ceiling and walls. The validity of measuring the color difference of stains was examined by installing teflon plates in the kitchen and the adjacent space with a view to assessing the oil diffusion. Four houses were designated for the examination. In each house, four teflon plates (20×40mm) were installed on the ceiling and walls of the kitchen and the space adjacent to it. Then, one plate was removed a...

  10. Pressure vessel for nuclear reactors

    International Nuclear Information System (INIS)

    1975-01-01

    The invention applies to a pressure vessel for nuclear reactors whose shell, made of cast metal segments, has a steel liner. This liner must be constructed to withstand all operational stresses and to be easily repairable. The invention solves this problem by installing the liner at a certain distance from the inner wall of the pressure vessel shell and by filling this clearance with supporting concrete. Both the concrete and the steel liner must have a lower prestress than the pressure vessel shell. In order to avoid damage to the liner when prestressing the pressure vessel shell, special connecting elements are provided which consist of welded-on fastening elements projecting into recesses in the cast metal segments of the pressure vessel. Their design is described in detail. (TK) [de

  11. Containment vessel stability analysis

    International Nuclear Information System (INIS)

    Harstead, G.A.; Morris, N.F.; Unsal, A.I.

    1983-01-01

    The stability analysis for a steel containment shell is presented herein. The containment is a freestanding shell consisting of a vertical cylinder with a hemispherical dome. It is stiffened by large ring stiffeners and relatively small longitudinal stiffeners. The containment vessel is subjected to both static and dynamic loads which can cause buckling. These loads must be combined prior to their use in a stability analysis. The buckling loads were computed with the aid of the ASME Code case N-284 used in conjunction with general purpose computer codes and in-house programs. The equations contained in the Code case were used to compute the knockdown factors due to shell imperfections. After these knockdown factors were applied to the critical stress states determined by freezing the maximum dynamic stresses and combining them with other static stresses, a linear bifurcation analysis was carried out with the aid of the BOSOR4 program. Since the containment shell contained large penetrations, the Code case had to be supplemented by a local buckling analysis of the shell area surrounding the largest penetration. This analysis was carried out with the aid of the NASTRAN program. Although the factor of safety against buckling obtained in this analysis was satisfactory, it is claimed that the use of the Code case knockdown factors are unduly conservative when applied to the analysis of buckling around penetrations. (orig.)

  12. Pressure vessel design

    International Nuclear Information System (INIS)

    Annaratone, D.

    2007-01-01

    This book guides through general and fundamental problems of pressure vessel design. It moreover considers problems which seem to be of lower importance but which turn out to be crucial in the design phase. The basic approach is rigorously scientific with a complete theoretical development of the topics treated, but the analysis is always pushed so far as to offer concrete and precise calculation criteria that can be immediately applied to actual designs. This is accomplished through appropriate algorithms that lead to final equations or to characteristic parameters defined through mathematical equations. The first chapter describes how to achieve verification criteria, the second analyzes a few general problems, such as stresses of the membrane in revolution solids and edge effects. The third chapter deals with cylinders under pressure from the inside, while the fourth focuses on cylinders under pressure from the outside. The fifth chapter covers spheres, and the sixth is about all types of heads. Chapter seven discusses different components of particular shape as well as pipes, with special attention to flanges. The eighth chapter discusses the influence of holes, while the ninth is devoted to the influence of supports. Finally, chapter ten illustrates the fundamental criteria regarding fatigue analysis. Besides the unique approach to the entire work, original contributions can be found in most chapters, thanks to the author's numerous publications on the topic and to studies performed ad hoc for this book. (orig.)

  13. Efficient scanning of thick lead vessels

    International Nuclear Information System (INIS)

    Raghunath, V.M.; Bhatnagar, P.K.; Meenakshisundaram, V.

    1978-01-01

    Lead containers fabricated for transport of radioactive materials need to be evaluated for their shielding integrity. The common method of locating a strong gamma source inside the vessel and scanning the external surface by conventional detectors suffers from high radiation dose and low sensitivity. A new method has been proposed and tried. It is found to be more efficient. In the new method, 60 Co source is loaded at the centre of the lead vessel and the outer surface is scanned by NaI(Tl) detector. The transmitted virgin flux is scanned under the 60 Co channel in a single channel analyser. An area of 25 cm 2 is scanned for 10 to 20 seconds each time. The source strength required is considerably reduced by a factor of 10 or more as compared to the common method and external dose rates do not exceed 50 mR/h (130 nC. kg -1 h -1 ) on the vessel surface. The advantages are improved sensitivity, no interference from scattered radiation and assurance in repeatability of measurements. (M.G.B.)

  14. Evaluation of a fluorescent lectin-based staining technique for some acidophilic mining bacteria

    International Nuclear Information System (INIS)

    Fife, D.J.; Bruhn, D.F.; Miller, K.S.; Stoner, D.L.

    2000-01-01

    A fluorescence-labeled wheat germ agglutinin staining technique was modified and found to be effective for staining gram-positive, acidophilic mining bacteria. Bacteria identified by others as being gram positive through 16S rRNA sequence analyses, yet clustering near the divergence of that group, stained weakly. Gram-negative bacteria did not stain. Background staining of environmental samples was negligible, and pyrite and soil particles in the samples did not interfere with the staining procedure

  15. Biofilm detection in chronic rhinosinusitis by combined application of hematoxylin-eosin and gram staining.

    Science.gov (United States)

    Tóth, László; Csomor, Péter; Sziklai, István; Karosi, Tamás

    2011-10-01

    The pathomechanism of chronic rhinosinusitis with nasal polyposis (CRS/NP) seems to be unclear. Bacterial-, fungal- and combined biofilms might play a potential role in the pathogenesis of various inflammatory diseases and recently in CRS/NP. A prospective, blinded observational study was performed to confirm that the combination of conventional hematoxylin-eosin (HE) and Gram staining protocols could be used to detect bacterial and fungal biofilms in patients with CRS/NP. A total of 50 patients with CRS/NP undergoing endoscopic sinus surgery (ESS) were analyzed. The negative control group consisted of 12 patients undergoing septoplasty for nasal obstruction without CRS/NP. The nasal polyps and inferior turbinate mucosa specimens applied as negative controls were processed to HE and Gram staining. Biofilm was detected in 44 of 50 patients with CRS/NP and in none of 12 negative controls. In our series, HE method showed an obvious correlation with the results of Gram staining and was allocated to be a good predictor of biofilm existence. It was found that the microscopic structure and thickness of biofilms were strongly associated with the integrity of nasal mucosa and with the characteristics of subepithelial cellular infiltration. This study confirmed the presence of bacterial and fungal biofilms on the surface of NPs obtained from patients with CRS. Since biofilms may affect the severity and recurrence rate of CRS treated by ESS they should be detected histologically. In conclusion, HE staining combined with Gram protocol is a robust and reliable method for the detection of bacterial and fungal biofilms in CRS/NP.

  16. Novel method for edge detection of retinal vessels based on the model of the retinal vascular network and mathematical morphology

    Science.gov (United States)

    Xu, Lei; Zheng, Xiaoxiang; Zhang, Hengyi; Yu, Yajun

    1998-09-01

    Accurate edge detection of retinal vessels is a prerequisite for quantitative analysis of subtle morphological changes of retinal vessels under different pathological conditions. A novel method for edge detection of retinal vessels is presented in this paper. Methods: (1) Wavelet-based image preprocessing. (2) The signed edge detection algorithm and mathematical morphological operation are applied to get the approximate regions that contain retinal vessels. (3) By convolving the preprocessed image with a LoG operator only on the detected approximate regions of retinal vessels, followed by edges refining, clear edge maps of the retinal vessels are fast obtained. Results: A detailed performance evaluation together with the existing techniques is given to demonstrate the strong features of our method. Conclusions: True edge locations of retinal vessels can be fast detected with continuous structures of retinal vessels, less non- vessel segments left and insensitivity to noise. The method is also suitable for other application fields such as road edge detection.

  17. Fine structural alterations of the blood vessels in the delayed radionecrosis of the human brain and its pathogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, H [Nagasaki Univ. (Japan). School of Medicine

    1981-05-01

    The blood vessels in the delayed radionecrosis of the human brain were studied under light and electron microscopes. Microscopically, the blood vessels demonstrated characteristic findings such as fibrinoid necrosis, hyalinized thickened vessels, perivascular fibrosis and thrombosed vessels. Electron microscopy revealed the formation of fenestrae, separation of endothelial cells, increased pinocytotic vesicles as well as the initial thrombus formation. Our results strongly verified that vascular alterations are primary in the pathogenesis of radionecrosis whereas the parenchymal changes are secondary.

  18. A generally applicable sequential alkaline phosphatase immunohistochemical double staining

    NARCIS (Netherlands)

    van der Loos, Chris M.; Teeling, Peter

    2008-01-01

    A universal type of sequential double alkaline phosphatase immunohistochemical staining is described that can be used for formalin-fixed, paraffin-embedded and cryostat tissue sections from human and mouse origin. It consists of two alkaline phosphatase detection systems including enzymatic

  19. Pre-staining thin layer chromatography method for amino acid ...

    African Journals Online (AJOL)

    Jane

    2010-12-13

    Dec 13, 2010 ... inexpensive and the results obtained were clean and reproducible. However, it is suitable for the high throughput screening of amino acid-producing strains. Key words: Thin layer chromatography, pre-staining, amino acid detection. INTRODUCTION. Several analytical techniques have been often used for.

  20. Color and dichroism of silver-stained glasses

    International Nuclear Information System (INIS)

    Molina, Gloria; Murcia, Sonia; Molera, Judit; Roldan, Clodoaldo; Crespo, Daniel; Pradell, Trinitat

    2013-01-01

    Yellow decorations in glasses have been produced since the beginning of the fourteenth century by incorporating metallic silver nanoparticles into the glass (from a few to some tens of nanometers). The optical response of the glass-particles composite is determined by the surface plasmon resonance absorption and scattering of the nanometric metallic particles. Generally, the same color is perceived in reflection and in transmission although dichroic effects are occasionally observed. As silver-stained glasses were designed to be observed in transmission, tuning the transmission color from yellow to red was of technological interest. The relationship between the color observed both in transmission and reflection and the composition and nanostructure of regular (yellow) and dichroic (yellow and red) silver stains from the Renaissance (late fifteenth and sixteenth century, respectively) is related to the presence of a layer (of about 10–20 μm thick) of metallic silver nanoparticles (from few to 100 nm in size). The correlation between the colors observed and the silver stain nanostructure is studied with particular emphasis on the origin of the dichroic behavior. The optical response is computed and compared to the experimental data. Differences in the synthesis parameters responsible for the colors and for the dichroic behavior of the silver stain glasses are proposed. This is essential for the replication of the glass pieces which are required as replacements in the restoration/conservation of the windows but is also of broader interest

  1. Alternate gram staining technique using a fluorescent lectin.

    Science.gov (United States)

    Sizemore, R K; Caldwell, J J; Kendrick, A S

    1990-01-01

    Fluorescence-labeled wheat germ agglutinin binds specifically to N-acetylglucosamine in the outer peptidoglycan layer of gram-positive bacteria. The peptidoglycan layer of gram-negative bacteria is covered by a membrane and is not labeled by the lectin. By exploiting this phenomenon, an alternative Gram staining technique has been developed. Images PMID:1697149

  2. Black stain and dental caries in Filipino schoolchildren.

    NARCIS (Netherlands)

    Heinrich-Weltzien, R.; Monse, B.; Palenstein Helderman, W.H. van

    2009-01-01

    Black stain is defined as dark pigmented exogenous substance in lines or dots parallel to the gingival margin and firmly adherent to the enamel at the cervical third of the tooth crowns in the primary and permanent dentition. OBJECTIVES: This study was conducted to assess the prevalence of black

  3. The use of special stains in liver biopsy interpretation: Implications ...

    African Journals Online (AJOL)

    2015-12-03

    Dec 3, 2015 ... Key words: Biliary disease, iron overload, liver biopsy, special stains. Date of Acceptance: 03-Dec- .... effect of cutting fresh sections after trimming. This limits ... alcohol as a significant factor in the iron deposition found in these ...

  4. Amalgam stained dentin: a proper substrate for bonding resin composite?

    NARCIS (Netherlands)

    Scholtanus, J.D.

    2016-01-01

    Nowadays the use of dental amalgam is mostly abandoned and substituted by tooth colored resin composites that can be bonded to teeth tissues by adhesive techniques. The aim of this thesis was to find out whether dark stained dentin, as often observed after removal of amalgam restorations and

  5. Color and dichroism of silver-stained glasses

    Energy Technology Data Exchange (ETDEWEB)

    Molina, Gloria [Universitat Politecnica de Catalunya, Center for Research in NanoEngineering (Spain); Murcia, Sonia [Universidad de Valencia, Instituto de Ciencia de los Materiales (Spain); Molera, Judit [Universitat de Vic, GRTD, Escola Politecnica Superior (Spain); Roldan, Clodoaldo [Universidad de Valencia, Instituto de Ciencia de los Materiales (Spain); Crespo, Daniel; Pradell, Trinitat, E-mail: Trinitat.Pradell@upc.edu [Universitat Politecnica de Catalunya, Center for Research in NanoEngineering (Spain)

    2013-09-15

    Yellow decorations in glasses have been produced since the beginning of the fourteenth century by incorporating metallic silver nanoparticles into the glass (from a few to some tens of nanometers). The optical response of the glass-particles composite is determined by the surface plasmon resonance absorption and scattering of the nanometric metallic particles. Generally, the same color is perceived in reflection and in transmission although dichroic effects are occasionally observed. As silver-stained glasses were designed to be observed in transmission, tuning the transmission color from yellow to red was of technological interest. The relationship between the color observed both in transmission and reflection and the composition and nanostructure of regular (yellow) and dichroic (yellow and red) silver stains from the Renaissance (late fifteenth and sixteenth century, respectively) is related to the presence of a layer (of about 10-20 {mu}m thick) of metallic silver nanoparticles (from few to 100 nm in size). The correlation between the colors observed and the silver stain nanostructure is studied with particular emphasis on the origin of the dichroic behavior. The optical response is computed and compared to the experimental data. Differences in the synthesis parameters responsible for the colors and for the dichroic behavior of the silver stain glasses are proposed. This is essential for the replication of the glass pieces which are required as replacements in the restoration/conservation of the windows but is also of broader interest.

  6. A comparison study of histochemical staining of various tissues after ...

    African Journals Online (AJOL)

    mean =5.28) then Carnoy's (mean = 4.00). For Alcian blue and Perl's Prussian blue, the best staining qualities were obtained by Formalin (mean = 4.76 and 5.64 respectively) followed by Carnoy's (mean = 2.88 and 3.92 respectively).

  7. Christendom's Narratives and the Stained Glass Designs of Yusuf ...

    African Journals Online (AJOL)

    This paper attempts a recast of Christendom's narratives in the stained glass designs of Yusuf Cameron Adebayo Grillo as the distinctive overarching mechanism of the evangelisation paradigm of the post Vatican II Church. It, therefore, draws attention to the delimitation of time frames in the history of the art form. Using the ...

  8. Comparison of various staining techniques in the diagnosis of ...

    African Journals Online (AJOL)

    Journal of Medical and Biomedical Sciences ... This can be achieved via various diagnostic techniques, commonly microscopy in this environment, hence the need to compare the efficacy of the commonly ... The objective of the study is to identify the most effective of the commonly used stains in identifying these parasites.

  9. Stain-free histopathology by programmable supercontinuum pulses

    DEFF Research Database (Denmark)

    Tu, Haohua; Liu, Yuan; Turchinovich, Dmitry

    2016-01-01

    The preparation, staining, visualization and interpretation of histological images of tissue is well accepted as the gold standard process for the diagnosis of disease. These methods have a long history of development, and are used ubiquitously in pathology, despite being highly time- and labour-...

  10. A comparision of modified and standard papanicolaou staining ...

    African Journals Online (AJOL)

    Objective: To compare modified and standard Papanicolaou (Pap) staining methods in the assessment of the cervical smears. Design: A descriptive cross sectional study. setting: Kenyatta National Hospital. Subjects: One hundred and sixty two women who were eligible for a pap smear and met the inclusion criteria.

  11. Borax methylene blue: a spectroscopic and staining study.

    Science.gov (United States)

    Donaldson, P T; Russo, A; Reynolds, C; Lillie, R D

    1978-07-01

    Borax methylene blue is quite stable at room temperatures of 22-25 C. At 30 C polychroming is slow; during 50 days in a water bath at this temperature the absorption peak moves from 665 to 656 nm. At 35 C, the absorption peak reaches 660 nm in 7 days, 654 nm in 14. At 60 C polychroming is rapid, the absorption peak reaching 640-620 nm in 3 days. When the pH of the borax methylene blue solutions, normally about 9.0, is adjusted to pH 6.5, the absorption peak remains at 665 nm even when incubated at 60 C for extended periods. When used as a blood stain 0.4 ml borax methylene blue (1% methylene blue in 1% borax), 4 ml acetone, 2 ml borax-acid phosphate buffer to bring the solution to pH 6.5, and distilled water to make 40 ml, with 0.2 ml 1% eosin added just before using, an excellent Nocht-Giemsa type stain is achieved after 30 minutes staining. The material plasmodia P. falciparum, P. vivax, and P. berghei stain moderate blue with dark red chromatin and green to black pigment granules. The study confirms Malachowski's 1891 results and explains Gautier's 1896-98 failure to duplicate it.

  12. a comparison of modified and standard papanicolaou staining ...

    African Journals Online (AJOL)

    2011-07-07

    Jul 7, 2011 ... modified pap method and standard Papanicolaou method respectively. The staining characteristics in .... alcohol was replaced by 0.5 % acetic acid and also, .... was 37.1, standard deviation of 8.0 and a median of. 36.5 years.

  13. Interlaboratory variability of Ki67 staining in breast cancer

    NARCIS (Netherlands)

    Focke, Cornelia M.; Bürger, Horst; van Diest, Paul J.; Finsterbusch, Kai; Gläser, Doreen; Korsching, Eberhard; Decker, Thomas; Anders, M.; Bollmann, R.; Eiting, Fr; Friedrich, K.; Habeck, J. O.; Haroske, G.; Hinrichs, B.; Behrens, A.; Krause, Lars Udo; Braun-Lang, U.; Lorenzen, J.; Minew, N.; Mlynek-Kersjes, M.; Nenning, H.; Packeisen, J.; Poche-de Vos, F.; Reyher-Klein, S.; Rothacker, D.; Schultz, M.; Sturm, U.; Tawfik, M.; Berghäuser, K. H.; Böcker, W; Cserni, G.; Habedank, S.; Lax, S.; Moinfar, F.; Regitnig, P.; Reiner-Concin, A.; Rüschoff, J.; Varga, Z.; Woziwodski, J.

    2017-01-01

    Background Postanalytic issues of Ki67 assessment in breast cancers like counting method standardisation and interrater bias have been subject of various studies, but little is known about analytic variability of Ki67 staining between pathology labs. Our aim was to study interlaboratory variability

  14. Human Lymphatic Mesenteric Vessels: Morphology and Possible Function of Aminergic and NPY-ergic Nerve Fibers.

    Science.gov (United States)

    D'Andrea, Vito; Panarese, Alessandra; Taurone, Samanta; Coppola, Luigi; Cavallotti, Carlo; Artico, Marco

    2015-09-01

    The lymphatic vessels have been studied in different organs from a morphological to a clinical point of view. Nevertheless, the knowledge of the catecholaminergic control of the lymphatic circulation is still incomplete. The aim of this work is to study the presence and distribution of the catecholaminergic and NPY-ergic nerve fibers in the whole wall of the human mesenteric lymphatic vessels in order to obtain knowledge about their morphology and functional significance. The following experimental procedures were performed: 1) drawing of tissue containing lymphatic vessels; 2) cutting of tissue; 3) staining of tissue; 4) staining of nerve fibers; 5) histofluorescence microscopy for the staining of catecholaminergic nerve fibers; 6) staining of neuropeptide Y like-immune reactivity; 7) biochemical assay of proteins; 8) measurement of noradrenaline; 9) quantitative analysis of images; 10) statistical analysis of data. Numerous nerve fibers run in the wall of lymphatic vessels. Many of them are catecholaminergic in nature. Some nerve fibers are NPY-positive. The biochemical results on noradrenaline amounts are in agreement with morphological results on catecholaminergic nerve fibers. Moreover, the morphometric results, obtained by the quantitative analysis of images and the subsequent statistical analysis of data, confirm all our morphological and biochemical data. The knowledge of the physiological or pathological mechanism regulating the functions of the lymphatic system is incomplete. Nevertheless the catecholaminergic nerve fibers of the human mesenteric lymphatic vessels come from the adrenergic periarterial plexuses of the mesenterial arterial bed. NPY-ergic nerve fibers may modulate the microcirculatory mesenterial bed in different pathological conditions.

  15. PWR vessel flaw distribution development

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kennedy, E.L.; Foulds, J.R.; Kinsman, K.M.

    1990-01-01

    This paper reports on PWR pressure vessels which operate under NRC rules and regulatory guides intended to prevent failure of the vessels. Plants failing to meet the operating criteria specified under these rules and regulations are required to analytically demonstrate fitness for service in order to continue operation. The initial flaw size or distribution of initial vessel flaws is a key input to the required vessel integrity analyses. However, the flaw distribution assumed in the development of the NRC Regulations and recommended for the plant specific analyses is potentially over-conservative. This is because the distribution is based on the limited amount of vessel inspection data available at the time the criteria were being developed and does not take full advantage of the more recent and reliable domestic vessel inspection results. The U.S. Department of Energy is funding an effort through Sandia National Laboratories to investigate the possibility of developing a new flaw distribution based on the increased amount and improved reliability of domestic vessel inspection data. Results of Phase I of the program indicate that state-of-the-art NDE systems' capabilities are sufficient for development of a new flaw distribution that could ultimately provide life extension benefits over the presently required operating practice

  16. Nuclear reactor vessel decontamination systems

    International Nuclear Information System (INIS)

    McGuire, P. J.

    1985-01-01

    There is disclosed in the present application, a decontamination system for reactor vessels. The system is operatable without entry by personnel into the contaminated vessel before the decontamination operation is carried out and comprises an assembly which is introduced into the vertical cylindrical vessel of the typical boiling water reactor through the open top. The assembly includes a circular track which is centered by guideways permanently installed in the reactor vessel and the track guides opposed pairs of nozzles through which water under very high pressure is directed at the wall for progressively cutting and sweeping a tenacious radioactive coating as the nozzles are driven around the track in close proximity to the vessel wall. The whole assembly is hoisted to a level above the top of the vessel by a crane, outboard slides on the assembly brought into engagement with the permanent guideways and the assembly progressively lowered in the vessel as the decontamination operation progresses. The assembly also includes a low pressure nozzle which forms a spray umbrella above the high pressure nozzles to contain radioactive particles dislodged during the decontamination

  17. Gammatography of thick lead vessels

    International Nuclear Information System (INIS)

    Raghunath, V.M.; Bhatnagar, P.K.; Sundaram, V.M.

    1979-01-01

    Radiography, scintillation and GM counting and dose measurements using ionisation chamber equipment are commonly used for detecting flaws/voids in materials. The first method is mostly used for steel vessels and to a lesser extent thin lead vessels also and is essentially qualitative. Dose measuring techniques are used for very thick and large lead vessels for which high strength radioactive sources are required, with its inherent handling problems. For vessels of intermediate thicknesses, it is ideal to use a small strength source and a GM or scintillation counter assembly. At the Reactor Research Centre, Kalpakkam, such a system was used for checking three lead vessels of thicknesses varying from 38mm to 65mm. The tolerances specified were +- 4% variation in lead thickness. The measurements also revealed the non concentricity of one vessel which had a thickness varying from 38mm to 44mm. The second vessel was patently non-concentric and the dimensional variation was truly reproduced in the measurements. A third vessel was fabricated with careful control of dimensions and the measurements exhibited good concentricity. Small deviations were observed, attributable to imperfect bondings between steel and lead. This technique has the following advantages: (a) weaker sources used result in less handling problems reducing the personnel exposures considerably; (b) the sensitivity of the instrument is quite good because of better statistics; (c) the time required for scanning a small vessel is more, but a judicious use of a scintillometer for initial fast scan will help in reducing the total scanning time; (d) this method can take advantage of the dimensional variations themselves to get the calibration and to estimate the deviations from specified tolerances. (auth.)

  18. [Improvement of Phi bodies stain and its clinical significance].

    Science.gov (United States)

    Gong, Xu-Bo; Lu, Xing-Guo; Yan, Li-Juan; Xiao, Xi-Bin; Wu, Dong; Xu, Gen-Bo; Zhang, Xiao-Hong; Zhao, Xiao-Ying

    2009-02-01

    The aim of this study was to improve the dyeing method of hydroperoxidase (HPO), to analyze the morphologic features of Phi bodies and to evaluate the clinical application of this method. 128 bone marrow or peripheral blood smears from patients with myeloid and lymphoid malignancies were stained by improved HPO staining. The Phi bodies were observed with detection rate of Phi bodies in different leukemias. 69 acute myeloid leukemia (AML) specimens were chosen randomly, the positive rate and the number of Phi bodies between the improved HPO and POX stain based on the same substrate of 3, 3'diaminobenzidine were compared. The results showed that the shape of bundle-like Phi bodies was variable, long or short. while the nubbly Phi bodies often presented oval and smooth. Club-like Phi bodies were found in M(3). The detection rates of bundle-like Phi bodies in AML M(1)-M(5) were 42.9% (6/14), 83.3% (15/18), 92.0% (23/25), 52.3% (11/21), 33.3% (5/15) respectively, and those of nubbly Phi bodies were 28.6% (4/14), 66.7% (12/18), 11.1% (3/25), 33.3% (7/21), 20.0% (3/15) respectively. The detection rate of bundle-like Phi bodies in M(3) was significantly higher than that in (M(1) + M(2)) or (M(4) + M(5)) groups. The detection rate of nubbly Phi bodies in (M(1) + M(2)) group was higher than that in M(3) group. In conclusion, after improvement of staining method, the HPO stain becomes simple, the detection rate of Phi bodies is higher than that by the previous method, the positive granules are more obvious, and the results become stable. This improved method plays an important role in differentiating AML from ALL, subtyping AML, and evaluating the therapeutic results.

  19. BY FRUSTUM CONFINING VESSEL

    Directory of Open Access Journals (Sweden)

    Javad Khazaei

    2016-09-01

    Full Text Available Helical piles are environmentally friendly and economical deep foundations that, due to environmental considerations, are excellent additions to a variety of deep foundation alternatives available to the practitioner. Helical piles performance depends on soil properties, the pile geometry and soil-pile interaction. Helical piles can be a proper alternative in sensitive environmental sites if their bearing capacity is sufficient to support applied loads. The failure capacity of helical piles in this study was measured via an experimental research program that was carried out by Frustum Confining Vessel (FCV. FCV is a frustum chamber by approximately linear increase in vertical and lateral stresses along depth from top to bottom. Due to special geometry and applied bottom pressure, this apparatus is a proper choice to test small model piles which can simulate field stress conditions. Small scale helical piles are made with either single helix or more helixes and installed in fine grained sand with three various densities. Axial loading tests including compression and tension tests were performed to achieve pile ultimate capacity. The results indicate the helical piles behavior depends essentially on pile geometric characteristics, i.e. helix configuration and soil properties. According to the achievements, axial uplift capacity of helical model piles is about equal to usual steel model piles that have the helixes diameter. Helical pile compression bearing capacity is too sufficient to act as a medium pile, thus it can be substituted other piles in special geoenvironmental conditions. The bearing capacity also depends on spacing ratio, S/D, and helixes diameter.

  20. Strongly interacting Fermi gases

    Directory of Open Access Journals (Sweden)

    Bakr W.

    2013-08-01

    Full Text Available Strongly interacting gases of ultracold fermions have become an amazingly rich test-bed for many-body theories of fermionic matter. Here we present our recent experiments on these systems. Firstly, we discuss high-precision measurements on the thermodynamics of a strongly interacting Fermi gas across the superfluid transition. The onset of superfluidity is directly observed in the compressibility, the chemical potential, the entropy, and the heat capacity. Our measurements provide benchmarks for current many-body theories on strongly interacting fermions. Secondly, we have studied the evolution of fermion pairing from three to two dimensions in these gases, relating to the physics of layered superconductors. In the presence of p-wave interactions, Fermi gases are predicted to display toplogical superfluidity carrying Majorana edge states. Two possible avenues in this direction are discussed, our creation and direct observation of spin-orbit coupling in Fermi gases and the creation of fermionic molecules of 23Na 40K that will feature strong dipolar interactions in their absolute ground state.

  1. A strong comeback

    International Nuclear Information System (INIS)

    Marier, D.

    1992-01-01

    This article presents the results of a financial rankings survey which show a strong economic activity in the independent energy industry. The topics of the article include advisor turnover, overseas banks, and the increase in public offerings. The article identifies the top project finance investors for new projects and restructurings and rankings for lenders

  2. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Hagiwara, Koji; Imura, Yasuya.

    1979-01-01

    Purpose: To provide constituted method for easily performing baking of vacuum vessel, using short-circuiting segments. Constitution: At the time of baking, one turn circuit is formed by the vacuum vessel and short-circuiting segments, and current transformer converting the one turn circuit into a secondary circuit by the primary coil and iron core is formed, and the vacuum vessel is Joule heated by an induction current from the primary coil. After completion of baking, the short-circuiting segments are removed. (Kamimura, M.)

  3. PWR vessel inspection performance improvements

    International Nuclear Information System (INIS)

    Blair Fairbrother, D.; Bodson, Francis

    1998-01-01

    A compact robot for ultrasonic inspection of reactor vessels has been developed that reduces setup logistics and schedule time for mandatory code inspections. Rather than installing a large structure to access the entire weld inspection area from its flange attachment, the compact robot examines welds in overlapping patches from a suction cup anchor to the shell wall. The compact robot size allows two robots to be operated in the vessel simultaneously. This significantly reduces the time required to complete the inspection. Experience to date indicates that time for vessel examinations can be reduced to fewer than four days. (author)

  4. Special enclosure for a pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.; Wedellsborg, U.W.

    1993-01-01

    A pressure vessel enclosure is described comprising a primary pressure vessel, a first pressure vessel containment assembly adapted to enclose said primary pressure vessel and be spaced apart therefrom, a first upper pressure vessel jacket adapted to enclose the upper half of said first pressure vessel containment assembly and be spaced apart therefrom, said upper pressure vessel jacket having an upper rim and a lower rim, each of said rims connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, mean for connecting in a sealable relationship said upper rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, means for connecting in a sealable relationship said lower rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a first lower pressure vessel jacket adapted to enclose the lower half of said first pressure vessel containment assembly and be spaced apart therefrom, said lower pressure vessel jacket having an upper rim connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, and means for connecting in a sealable relationship said upper rim of said first lower pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a second upper pressure vessel jacket adapted to enclose said first upper pressure vessel jacket and be spaced apart therefrom, said second upper pressure vessel jacket having an upper rim and a lower rim, each of said rims adapted to slidably engage the outer surface of said first upper pressure vessel jacket, means for sealing said rims, a second lower pressure vessel jacket adapted to enclose said first lower pressure vessel jacket and be spaced apart therefrom

  5. Development of a preparation and staining method for fetal erythroblasts in maternal blood : Simultaneous immunocytochemical staining and FISH analysis

    NARCIS (Netherlands)

    Oosterwijk, JC; Mesker, WE; Ouwerkerk-van Velzen, MCM; Knepfle, CFHM; Wiesmeijer, KC; van den Burg, MJM; Beverstock, GC; Bernini, LF; van Ommen, Gert-Jan B; Kanhai, HHH; Tanke, HJ

    1998-01-01

    In order to detect fetal nucleated red blood cells (NRBCs) in maternal blood, a protocol was developed which aimed at producing a reliable staining method for combined immunocytochemical and FISH analysis. The technique had to be suitable for eventual automated screening of slides. Chorionic villi

  6. Intravital two-photon microscopy of immune cell dynamics in corneal lymphatic vessels.

    Directory of Open Access Journals (Sweden)

    Philipp Steven

    Full Text Available BACKGROUND: The role of lymphatic vessels in tissue and organ transplantation as well as in tumor growth and metastasis has drawn great attention in recent years. METHODOLOGY/PRINCIPAL FINDINGS: We now developed a novel method using non-invasive two-photon microscopy to simultaneously visualize and track specifically stained lymphatic vessels and autofluorescent adjacent tissues such as collagen fibrils, blood vessels and immune cells in the mouse model of corneal neovascularization in vivo. The mouse cornea serves as an ideal tissue for this technique due to its easy accessibility and its inducible and modifiable state of pathological hem- and lymphvascularization. Neovascularization was induced by suture placement in corneas of Balb/C mice. Two weeks after treatment, lymphatic vessels were stained intravital by intrastromal injection of a fluorescently labeled LYVE-1 antibody and the corneas were evaluated in vivo by two-photon microscopy (TPM. Intravital TPM was performed at 710 nm and 826 nm excitation wavelengths to detect immunofluorescence and tissue autofluorescence using a custom made animal holder. Corneas were then harvested, fixed and analyzed by histology. Time lapse imaging demonstrated the first in vivo evidence of immune cell migration into lymphatic vessels and luminal transport of individual cells. Cells immigrated within 1-5.5 min into the vessel lumen. Mean velocities of intrastromal corneal immune cells were around 9 µm/min and therefore comparable to those of T-cells and macrophages in other mucosal surfaces. CONCLUSIONS: To our knowledge we here demonstrate for the first time the intravital real-time transmigration of immune cells into lymphatic vessels. Overall this study demonstrates the valuable use of intravital autofluorescence two-photon microscopy in the model of suture-induced corneal vascularizations to study interactions of immune and subsequently tumor cells with lymphatic vessels under close as possible

  7. 2013 West Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  8. 2011 West Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  9. 2013 Great Lakes Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  10. 2011 Great Lakes Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  11. 2011 East Coast Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  12. Coastal Discard Logbook Survey (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data on the type and amount of marine resources that are discarded or interacted with by vessels that are selected to report to the Southeast...

  13. SC/OQ Vessel Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Data tables holding information for the Surf Clam/Ocean Quahog vessel and dealer/processor logbooks (negative and positive), as well as individual tag information...

  14. Vessel Permit System Data Set

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — GARFO issues federal fishing permits annually to owners of fishing vessels who fish in the Greater Atlantic region, as required by federal regulation. These permits...

  15. Reactor pressure vessel status report

    International Nuclear Information System (INIS)

    Strosnider, J.; Wichman, K.; Elliot, B.

    1994-12-01

    This report gives a brief description of the reactor pressure vessel (RPV), followed by a discussion of the radiation embrittlement of RPV beltline materials and the two indicators for measuring embrittlement, the end-of-license (EOL) reference temperature and the EOL upper-shelf energy. It also summarizes the GL 92-01 effort and presents, for all 37 boiling water reactor plants and 74 pressurized water reactor plants in the United States, the current status of compliance with regulatory requirements related to ensuring RPV integrity. The staff has evaluated the material data needed to predict neutron embrittlement of the reactor vessel beltline materials. These data will be stored in a computer database entitled the reactor vessel integrity database (RVID). This database will be updated annually to reflect the changes made by the licensees in future submittals and will be used by the NRC staff to assess the issues related to vessel structural integrity

  16. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-07-01

    A successful technical demonstration of simulated reactor vessel sectioning was completed using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel: an air arc gouger was chosen to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. After the simulated vessel was successfully cut from the SS side, another cut was made, starting from the carbon steel side. This cut was also successful. Cutting from the carbon steel side has the advantages of cost reduction since the air arc gouging step is eliminated and contamination controlled because the molten metal is blown inward

  17. Investigation of the Application of miR10b and miR135b in the Identification of Semen Stains

    Science.gov (United States)

    Xue, Tianyu; Ma, Xiaoyan; Zhang, Jinxiang; Ou, Xueling; Cheng, Jianding; Sun, Hongyu

    2015-01-01

    To evaluate the identification method using the microRNA markers miR10b and miR135b to distinguish semen stains from menstrual blood, peripheral blood, vaginal fluid and so on body fluid stains. The expression levels of miR10b and miR35b in semen stains and menstrual blood and so on were detected utilizing a real-time quantitative PCR technique with a specific fluorescence-labeled TaqMan probe. RNU6b was used as the internal reference gene; the difference in their expression was analyzed, and the specificity, sensitivity, and detection capability of the techniques were evaluated. The expression of miR10b and miR135b in semen stains was significantly higher than that of other body fluid stains, with a mean value of ΔCт from-6 to-7. However, it ranged from-2 to-4 for other body fluid stains. The initial criteria for judging which semen stains can be identified were determined by analyzing the research results. When the threshold value was set to 0.04, the CT value could be detected in the target genes miR10b, miR135b and in the internal reference gene RNU6b, and CT values are<40, ΔCT[10b-U6]<-5.5, and ΔCT[135b-U6]<-6, respectively, and the semen stain could be identified. The expression levels of miR10b and miR135b are higher in semen with strong tissue specificity; thus, they can be used to differentiate semen stains from other body fluid stains in forensic science. PMID:26355456

  18. Investigation of the Application of miR10b and miR135b in the Identification of Semen Stains.

    Directory of Open Access Journals (Sweden)

    Dayue Tong

    Full Text Available To evaluate the identification method using the microRNA markers miR10b and miR135b to distinguish semen stains from menstrual blood, peripheral blood, vaginal fluid and so on body fluid stains. The expression levels of miR10b and miR35b in semen stains and menstrual blood and so on were detected utilizing a real-time quantitative PCR technique with a specific fluorescence-labeled TaqMan probe. RNU6b was used as the internal reference gene; the difference in their expression was analyzed, and the specificity, sensitivity, and detection capability of the techniques were evaluated. The expression of miR10b and miR135b in semen stains was significantly higher than that of other body fluid stains, with a mean value of ΔCт from-6 to-7. However, it ranged from-2 to-4 for other body fluid stains. The initial criteria for judging which semen stains can be identified were determined by analyzing the research results. When the threshold value was set to 0.04, the CT value could be detected in the target genes miR10b, miR135b and in the internal reference gene RNU6b, and CT values are<40, ΔCT[10b-U6]<-5.5, and ΔCT[135b-U6]<-6, respectively, and the semen stain could be identified. The expression levels of miR10b and miR135b are higher in semen with strong tissue specificity; thus, they can be used to differentiate semen stains from other body fluid stains in forensic science.

  19. Strong Electroweak Symmetry Breaking

    CERN Document Server

    Grinstein, Benjamin

    2011-01-01

    Models of spontaneous breaking of electroweak symmetry by a strong interaction do not have fine tuning/hierarchy problem. They are conceptually elegant and use the only mechanism of spontaneous breaking of a gauge symmetry that is known to occur in nature. The simplest model, minimal technicolor with extended technicolor interactions, is appealing because one can calculate by scaling up from QCD. But it is ruled out on many counts: inappropriately low quark and lepton masses (or excessive FCNC), bad electroweak data fits, light scalar and vector states, etc. However, nature may not choose the minimal model and then we are stuck: except possibly through lattice simulations, we are unable to compute and test the models. In the LHC era it therefore makes sense to abandon specific models (of strong EW breaking) and concentrate on generic features that may indicate discovery. The Technicolor Straw Man is not a model but a parametrized search strategy inspired by a remarkable generic feature of walking technicolor,...

  20. Power reactor pressure vessel benchmarks

    International Nuclear Information System (INIS)

    Rahn, F.J.

    1978-01-01

    A review is given of the current status of experimental and calculational benchmarks for use in understanding the radiation embrittlement effects in the pressure vessels of operating light water power reactors. The requirements of such benchmarks for application to pressure vessel dosimetry are stated. Recent developments in active and passive neutron detectors sensitive in the ranges of importance to embrittlement studies are summarized and recommendations for improvements in the benchmark are made. (author)

  1. Plasmons in strong superconductors

    International Nuclear Information System (INIS)

    Baldo, M.; Ducoin, C.

    2011-01-01

    We present a study of the possible plasmon excitations that can occur in systems where strong superconductivity is present. In these systems the plasmon energy is comparable to or smaller than the pairing gap. As a prototype of these systems we consider the proton component of Neutron Star matter just below the crust when electron screening is not taken into account. For the realistic case we consider in detail the different aspects of the elementary excitations when the proton, electron components are considered within the Random-Phase Approximation generalized to the superfluid case, while the influence of the neutron component is considered only at qualitative level. Electron screening plays a major role in modifying the proton spectrum and spectral function. At the same time the electron plasmon is strongly modified and damped by the indirect coupling with the superfluid proton component, even at moderately low values of the gap. The excitation spectrum shows the interplay of the different components and their relevance for each excitation modes. The results are relevant for neutrino physics and thermodynamical processes in neutron stars. If electron screening is neglected, the spectral properties of the proton component show some resemblance with the physical situation in high-T c superconductors, and we briefly discuss similarities and differences in this connection. In a general prospect, the results of the study emphasize the role of Coulomb interaction in strong superconductors.

  2. White matters - The influence of cerebral small-vessel disease on depression, cognition and functioning

    NARCIS (Netherlands)

    Grool, A.M.

    2012-01-01

    Depression and cognitive impairment are highly prevalent in later life, and frequently co-occur. One of the possible mechanisms that may underlie both conditions is the presence of cerebral small-vessel disease. The presence of cerebral small-vessel disease is strongly associated with common

  3. Prosopomorphic vessels from Moesia Superior

    Directory of Open Access Journals (Sweden)

    Nikolić Snežana

    2008-01-01

    Full Text Available The prosopomorphic vessels from Moesia Superior had the form of beakers varying in outline but similar in size. They were wheel-thrown, mould-made or manufactured by using a combination of wheel-throwing and mould-made appliqués. Given that face vessels are considerably scarcer than other kinds of pottery, more than fifty finds from Moesia Superior make an enviable collection. In this and other provinces face vessels have been recovered from military camps, civilian settlements and necropolises, which suggests that they served more than one purpose. It is generally accepted that the faces-masks gave a protective role to the vessels, be it to protect the deceased or the family, their house and possessions. More than forty of all known finds from Moesia Superior come from Viminacium, a half of that number from necropolises. Although tangible evidence is lacking, there must have been several local workshops producing face vessels. The number and technological characteristics of the discovered vessels suggest that one of the workshops is likely to have been at Viminacium, an important pottery-making centre in the second and third centuries.

  4. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Kurita, Gen-ichi; Onozuka, Masaki; Suzuki, Masaru.

    1997-01-01

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and γ rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  5. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Kurita, Gen-ichi [Japan Atomic Energy Research Inst., Tokyo (Japan); Onozuka, Masaki; Suzuki, Masaru

    1997-07-31

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and {gamma} rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  6. Persepsi Pemustaka Terhadap Kualitas Layanan Perpustakaan Pascasarjana STAIN Pamekasan

    Directory of Open Access Journals (Sweden)

    Hairul A Cahyo

    2014-07-01

    Full Text Available Library is one of supporting element from institute, which can fullfill user’s information need for teaching learning process especially in postgraduate STAIN Pamekasan. To create optimal and good service in postgraduate library, it can see from user’s perception in service quality in postgraduate STAIN Pamekasan. This research used data collection technic; observation, interview and documentation. Officer quality in giving servive to user visible in copability and attitude from officer it self. Library service also can see from collection of books in library to fullfill user’s need. Supporting tools in building and rooms. To complete some tools, it also need infrastructure to fullfill library needs in service. Infrastructure needed are utensils, it means to support library actinity which unused up such as; bookshelf, table and chair, computer and internet, air conditioner, room’s light or lamp, catalogue and photocopy machine.

  7. [Standardization of Blastocystis hominis diagnosis using different staining techniques].

    Science.gov (United States)

    Eymael, Dayane; Schuh, Graziela Maria; Tavares, Rejane Giacomelli

    2010-01-01

    The present study was carried out from March to May 2008, with the aim of evaluating the effectiveness of different techniques for diagnosing Blastocystis hominis in a sample of the population attended at the Biomedicine Laboratory of Feevale University, Novo Hamburgo, Rio Grande do Sul. On hundred feces samples from children and adults were evaluated. After collection, the samples were subjected to the techniques of spontaneous sedimentation (HPJ), sedimentation in formalin-ether (Ritchie) and staining by means of Gram and May-Grünwald-Giemsa (MGG). The presence of Blastocystis hominis was observed in 40 samples, when staining techniques were used (MGG and Gram), while sedimentation techniques were less efficient (32 positive samples using the Ritchie technique and 20 positive samples using the HPJ technique). Our results demonstrate that HPJ was less efficient than the other methods, thus indicating the need to include laboratory techniques that enable parasite identification on a routine basis.

  8. Lectins stain cells differentially in the coral, Montipora capitata

    Science.gov (United States)

    Work, Thierry M.; Farah, Yael

    2014-01-01

    A limitation in our understanding of coral disease pathology and cellular pathogenesis is a lack of reagents to characterize coral cells. We evaluated the utility of plant lectins to stain tissues of a dominant coral, Montipora capitata, from Hawaii. Of 22 lectins evaluated, nine of these stained structures in the upper or basal body wall of corals. Specific structures revealed by lectins that were not considered distinct or evident on routine hematoxylin and eosin sections of coral tissues included apical and basal granules in gastrodermis and epidermis, cnidoglandular tract and actinopharynx cell surface membranes, capsules of mature holotrichous isorhizas, and perivitelline and periseminal cells. Plant lectins could prove useful to further our understanding of coral physiology, anatomy, cell biology, and disease pathogenesis.

  9. Removing foxing stains from old paper at 157 nm

    International Nuclear Information System (INIS)

    Sarantopoulou, E.; Samardzija, Z.; Kobe, S.; Kollia, Z.; Cefalas, A.C.

    2003-01-01

    Using a molecular fluorine laser at 157 nm foxing stains were removed successfully from a 16th century old paper. Laser cleaning of stains and foxing from old paper manuscripts is far more effective at 157 nm in comparison to different wavelengths without leaving any yellowish after-effect on the paper. This is because at 157 nm illumination of old paper, complete bond breaking of all the organic molecules of the paper is taking place. Mass spectroscopy at 157 nm and for moderate laser intensities up to 1 mJ/cm 2 of old paper suffering from foxing indicate organic matter disintegration to small photofragments atomic, diatomic or triatomic, which are flying apart with supersonic speed. In addition high spatial resolution energy dispersive X-ray system (EDXS) analysis over the effected areas indicate the presence of iron, suggesting that biological activity is taking place preferentially in paper areas containing iron

  10. Solid-Color Stains on Western Redcedar and Redwood Siding

    Science.gov (United States)

    Mark Knaebe

    2013-01-01

    You have decided to put wood siding on your new house. Several questions are probably going through your mind: “What’s the best type of wood?” “Should I use paint or stain?” “Should I apply the finish before or after I install the siding?”

  11. An improved method for staining cell colonies in clonogenic assays

    OpenAIRE

    Guda, Kishore; Natale, Leanna; Markowitz, Sanford D.

    2007-01-01

    Clonogenic assay is a widely used experimental approach to test for the effects of drugs/genes on the growth and proliferative characteristics of cells in vitro. Accurate quantitation of treatment effects in clonogeneic assays depends on the ability to visualize and count cell colonies precisely. We report a novel method (referred as ETeB) for staining cell colonies grown on plastic and specially coated substrates like collagen. Using colon cancer cell lines grown on plastic and collagen, we ...

  12. PHACE syndrome misdiagnosed as a port-wine stain

    OpenAIRE

    Thomson, Jason; Greig, Aina; Lloyd, Claire; Morrison, Danny; Flohr, Carsten

    2015-01-01

    We present the case of a boy born with a large macular, segmental vascular anomaly over the left face, initially diagnosed as a capillary malformation (port-wine stain) by the postnatal paediatric team. The vascular anomaly in the face then grew rapidly during the first few weeks of life and started to occlude the left eye, causing parental concerns about the infant's vision. A dermatological opinion established that the lesion was a segmental infantile haemangioma (IH). This, in combination ...

  13. Hirschsprung's disease diagnosis: Comparison of immunohistochemical, hematoxilin and eosin staining

    OpenAIRE

    Memarzadeh, Mehrdad; Talebi, Ardeshir; Edalaty, Masod; Hosseinpour, Mehrdad; Vahidi, Nasrin

    2009-01-01

    Background: The diagnosis of Hirschsprung's disease (HD) is based on the absence of ganglion cells. In hemotoxilin and eosin (H and E) as well as acetylcholine esterase staining there are limitations in the diagnosis of immature ganglion cells in neonates. Methods: In this prospective study, 54 biopsies taken from suspected HD patients (five mucosal specimens and 49 full thickness specimens) were studied. In the laboratory, after preparing sections of paraffin embedded tissues, H and E staini...

  14. USE OF VITAL STAINING IN STORED HUMAN PLATELETS MORPHOFUNCTIONAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    M. S. Makarov

    2014-01-01

    Full Text Available Apheresis and pooled platelet concentrates, stored at 22°C during 5 days, were studied with morho-functional platelet rate analysis, based on vital cell staining and registration with fluorescent microscope. It was revealed that apheresis and pooled PC had, on the average, normal values of morphological and functional parameters. On the other hand, both PC kept MFPR of cells only for 2 days storage. Longer PC storage caused the significant decay of morphological and functional platelet parameters.

  15. Technique and Feasibility of a Dual Staining Method for Estrogen Receptors and AgNORs

    Directory of Open Access Journals (Sweden)

    Lukas Günther

    2000-01-01

    Full Text Available A new staining method for dual demonstration of Estrogen receptors (ER and argyrophilc Nucleolus‐Organizer Regions (AgNORs was developed. To rule out possible reciprocal effects, serial slides of 10 invasive ductale breast cancers were stained with either the single staining method or the simultaneous ER/AgNOR‐staining method and investigated comparatively. By measuring the slides with the image analysis system AMBA, reciprocal effects could be excluded. It was proven that dual staining of both markers results in a reproducible and specific staining result. We concluded that it is justified to measure AgNORs in immunohistochemically stained cells.

  16. Study of stained glass window using PIXE-PIGE

    International Nuclear Information System (INIS)

    Weber, G.; Bemden, Y. Vanden; Pirotte, M.; Gilbert, B.

    2005-01-01

    We had the opportunity to study a large panel (100x80cm) containing more than 40 stained glass pieces. Among them several come from restorations having taken place at different periods. The study of this rather complex arrangement has been processed by stages:- the elemental composition of 16 zones were determined: several differences were identified and among them the Na/K ratio which allowed to set three groups of glass type; - the measurement of the Na concentrations by the two techniques give information in bulk (PIGE) and at the near surface (PIXE); the values defined by the (C PIGE -C PIXE) )/C PIGE plotted in function of the historical estimation of the age of the stained glass pieces (original and restored) indicate a real correlation between the two variables; - the red-colored pieces were specially investigated in order to determine which coloration technique was employed (bulk coloration, superficial staining, multilayered flashing, etc.); - the corrosion was investigated by scanning two different worsened zones with a 0.5mm diameter beam spot. This study shows the possibilities of the PIGE-PIXE association, but also points out some weaknesses, which have to be solved by other techniques; unfortunately, in that case, the non-destructive aspect could be lost

  17. Evaluation of surviving fraction using nonclonogenic staining densitometry method

    International Nuclear Information System (INIS)

    Nishiguchi, Iku; Ogawa, Koichi; Ito, Hisao; Hashimoto, Shozo

    1994-01-01

    This study was performed to compare our nonclonogenic survival assay (densitometry assay, DM assay) with the widely used clonogenic assay. The established cell lines (HaLa, RMUG, IMR, GOTO) were grown in F 10 medium. The cells were spread in 24-well plates, irradiated with different doses, cultured for about one week and stained with crystal violet after the culture period. Taking the transparent images of the stained well on the light source with the CCD camera, the images were collected with the matrix size 64 x 64, and the integrated optical density of the entire surface of each well was determined by computer with our original program. As the number of cells in the well is reflected by its staining density, the surviving fraction was calculated as the fraction of growth in the irradiated wells relative to controls. The survival curves obtained by the densitometry method showed good correlations with those obtained by clonogenic assay. It is possible to predict intrinsic radiosensitivity with this assay, even if the cells do not form good colonies. However, this method is based on measurements in cultures which depend on the metabolism and growth kinetics of the irradiated cells. Cells should grow exponetially in the same manner in any well to obtain a result similar to that of clonogenic assay, although growth kinetics may be altered by irradiation. This, the endpoint must be strictly standardized. (author)

  18. Strongly intensive quantities

    International Nuclear Information System (INIS)

    Gorenstein, M. I.; Gazdzicki, M.

    2011-01-01

    Analysis of fluctuations of hadron production properties in collisions of relativistic particles profits from use of measurable intensive quantities which are independent of system size variations. The first family of such quantities was proposed in 1992; another is introduced in this paper. Furthermore we present a proof of independence of volume fluctuations for quantities from both families within the framework of the grand canonical ensemble. These quantities are referred to as strongly intensive ones. Influence of conservation laws and resonance decays is also discussed.

  19. Strong-coupling approximations

    International Nuclear Information System (INIS)

    Abbott, R.B.

    1984-03-01

    Standard path-integral techniques such as instanton calculations give good answers for weak-coupling problems, but become unreliable for strong-coupling. Here we consider a method of replacing the original potential by a suitably chosen harmonic oscillator potential. Physically this is motivated by the fact that potential barriers below the level of the ground-state energy of a quantum-mechanical system have little effect. Numerically, results are good, both for quantum-mechanical problems and for massive phi 4 field theory in 1 + 1 dimensions. 9 references, 6 figures

  20. Automated method for identification and artery-venous classification of vessel trees in retinal vessel networks.

    Science.gov (United States)

    Joshi, Vinayak S; Reinhardt, Joseph M; Garvin, Mona K; Abramoff, Michael D

    2014-01-01

    The separation of the retinal vessel network into distinct arterial and venous vessel trees is of high interest. We propose an automated method for identification and separation of retinal vessel trees in a retinal color image by converting a vessel segmentation image into a vessel segment map and identifying the individual vessel trees by graph search. Orientation, width, and intensity of each vessel segment are utilized to find the optimal graph of vessel segments. The separated vessel trees are labeled as primary vessel or branches. We utilize the separated vessel trees for arterial-venous (AV) classification, based on the color properties of the vessels in each tree graph. We applied our approach to a dataset of 50 fundus images from 50 subjects. The proposed method resulted in an accuracy of 91.44% correctly classified vessel pixels as either artery or vein. The accuracy of correctly classified major vessel segments was 96.42%.

  1. Strongly disordered superconductors

    International Nuclear Information System (INIS)

    Muttalib, K.A.

    1982-01-01

    We examine some universal effects of strong non-magnetic disorder on the electron-phonon and electron-electron interactions in a superconductor. In particular we explicitly take into account the effect of slow diffusion of electrons in a disordered medium by working in an exact impurity eigenstate representation. We find that the normal diffusion of electrons characterized by a constant diffusion coefficient does not lead to any significant correction to the electron-phonon or the effective electron-electron interactions in a superconductor. We then consider sufficiently strong disorder where Anderson localization of electrons becomes important and determine the effect of localization on the electron-electron interactions. We find that due to localization, the diffusion of electrons becomes anomalous in the sense that the diffusion coefficient becomes scale dependent. This results in an increase in the effective electron-electron interaction with increasing disorder. We propose that this provides a natural explanation for the unusual sensitivity of the transition temperature T/sub c/ of the high T/sub c/ superconductors (T/sub c/ > 10 0 K) to damage effects

  2. Strong Coupling Holography

    CERN Document Server

    Dvali, Gia

    2009-01-01

    We show that whenever a 4-dimensional theory with N particle species emerges as a consistent low energy description of a 3-brane embedded in an asymptotically-flat (4+d)-dimensional space, the holographic scale of high-dimensional gravity sets the strong coupling scale of the 4D theory. This connection persists in the limit in which gravity can be consistently decoupled. We demonstrate this effect for orbifold planes, as well as for the solitonic branes and string theoretic D-branes. In all cases the emergence of a 4D strong coupling scale from bulk holography is a persistent phenomenon. The effect turns out to be insensitive even to such extreme deformations of the brane action that seemingly shield 4D theory from the bulk gravity effects. A well understood example of such deformation is given by large 4D Einstein term in the 3-brane action, which is known to suppress the strength of 5D gravity at short distances and change the 5D Newton's law into the four-dimensional one. Nevertheless, we observe that the ...

  3. Low lymphatic vessel density associates with chronic rhinosinusitis with nasal polyps.

    Science.gov (United States)

    Luukkainen, A; Seppälä, M; Renkonen, J; Renkonen, R; Hagstrő M, J; Huhtala, H; Rautiainen, M; Myller, J; Paavonen, T; Ranta, A; Torkkeli, T; Toppila-Salmi, S

    2017-06-01

    Chronic rhinosinusitis with and without nasal polyps (CRSwNP and CRSsNP) and antrochoanal polyps (ACP) are different upper airway inflammation phenotypes with different pathomechanisms. In order to understand the development of tissue edema, the present study aimed to evaluate lymphatic vessel density in CRSsNP, CRSwNP and ACP. 120 retrospective nasal and maxillary sinus specimens were stained immunohistochemically with a von Willebrand factor polyclonal antibody recognizing vascular and lymphatic endothelium, and with a podoplanin monoclonal antibody recognizing lymphatic endothelium. Vessels were studied by microscopy in a blinded fashion, and the vessel density and the relative density of lymphatic vessels were calculated. Patient characteristic factors and follow-up data of in average 9 years were collected from patient records. In the nasal cavity, the low absolute and relative density of vessels and of lymphatic vessels was associated with CRSwNP and ACP tissues compared to control inferior turbinate. This was observed also in the inflammatory hotspot area. In the maxillary sinus, lower absolute and relative density of lymphatic vessels associated with the CRSwNP phenotype. High lymphatic vessel density in polyp tissue associated with the need for revision CRS-surgery. As a conclusion, low density of lymphatic vessels distinguished patients with CRSwNP not only in the hotspot area of polyp tissue, but also in maxillary sinus mucosa. Yet, higher lymphatic vessel density seems to associate with polyp recurrence. Further studies are still needed to explore if formation of nasal polyps could be diminished by intranasal therapeutics affecting lymphangiogenesis.

  4. Detection of radioactively labeled proteins is quenched by silver staining methods: quenching is minimal for 14C and partially reversible for 3H with a photochemical stain

    International Nuclear Information System (INIS)

    Van Keuren, M.L.; Goldman, D.; Merril, C.R.

    1981-01-01

    Silver staining methods for protein detection in polyacrylamide gels have a quenching effect on autoradiography and fluorography. This effect was quantitated for proteins in two-dimensional gels by microdensitometry using a computer equipped with an image processor and by scintillation counting of proteins solubilized from the gels. The original histologically derived silver stain had a quenching effect that was severe and irreversible for 3 H detection and moderate for 14 C detection. A silver stain based on photochemical methods had minimal quenching of 14 C detection and less of a quenching effect than the histological stain for 3 H detection. The 3 H quenching effect was partially reversible for the photochemical stain

  5. The TPX vacuum vessel and in-vessel components

    International Nuclear Information System (INIS)

    Heitzenroeder, P.; Bialek, J.; Ellis, R.; Kessel, C.; Liew, S.

    1994-01-01

    The Tokamak Physics Experiment (TPX) is a superconducting tokamak with double-null diverters. TPX is designed for 1,000-second discharges with the capability of being upgraded to steady state operation. High neutron yields resulting from the long duration discharges require that special consideration be given to materials and maintainability. A unique feature of the TPX is the use of a low activation, titanium alloy vacuum vessel. Double-wall vessel construction is used since it offers an efficient solution for shielding, bakeout and cooling. Contained within the vacuum vessel are the passive coil system, Plasma Facing Components (PFCs), magnetic diagnostics, and the internal control coils. All PFCs utilize carbon-carbon composites for exposed surfaces

  6. Waves and fluid-solid interaction in stented blood vessels

    Science.gov (United States)

    Frecentese, S.; Argani, L. P.; Movchan, A. B.; Movchan, N. V.; Carta, G.; Wall, M. L.

    2018-01-01

    This paper focuses on the modelling of fluid-structure interaction and wave propagation problems in a stented artery. Reflection of waves in blood vessels is well documented in the literature, but it has always been linked to a strong variation in geometry, such as the branching of vessels. The aim of this work is to detect the possibility of wave reflection in a stented artery due to the repetitive pattern of the stents. The investigation of wave propagation and possible blockages under time-harmonic conditions is complemented with numerical simulations in the transient regime.

  7. Clay Corner: Recreating Chinese Bronze Vessels.

    Science.gov (United States)

    Gamble, Harriet

    1998-01-01

    Presents a lesson where students make faux Chinese bronze vessels through slab or coil clay construction after they learn about the history, function, and design of these vessels. Utilizes a variety of glaze finishes in order to give the vessels an aged look. Gives detailed guidelines for creating the vessels. (CMK)

  8. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Nagashima, Keisuke; Suzuki, Masaru; Onozuka, Masaki.

    1997-01-01

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  9. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Nagashima, Keisuke [Japan Atomic Energy Research Inst., Tokyo (Japan); Suzuki, Masaru; Onozuka, Masaki

    1997-07-11

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  10. Molten material-containing vessel

    International Nuclear Information System (INIS)

    Akagawa, Katsuhiko

    1998-01-01

    The molten material-containing vessel of the present invention comprises a vessel main body having an entrance opened at the upper end, a lid for closing the entrance, an outer tube having an upper end disposed at the lower surface of the lid, extended downwardly and having an closed lower end and an inner tube disposed coaxially with the outer tube. When a molten material is charged from the entrance to the inside of the vessel main body of the molten material-containing vessel and the entrance is closed by the lid, the outer tube and the inner tube are buried in the molten material in the vessel main body, accordingly, a fluid having its temperature elevated by absorption of the heat of the molten material rises along the inner circumferential surface of the outer tube, abuts against the lower surface of the lid and cooled by exchanging heat with the lid and forms a circulating flow. Since the heat in the molten material is continuously absorbed by the fluid, transferred to the lid and released from the lid to the atmospheric air, heat releasing efficiency can be improved compared with conventional cases. (N.H.)

  11. LIGO: The strong belief

    CERN Multimedia

    Antonella Del Rosso

    2016-01-01

    Twenty years of designing, building and testing a number of innovative technologies, with the strong belief that the endeavour would lead to a historic breakthrough. The Bulletin publishes an abstract of the Courier’s interview with Barry Barish, one of the founding fathers of LIGO.   The plots show the signals of gravitational waves detected by the twin LIGO observatories at Livingston, Louisiana, and Hanford, Washington. (Image: Caltech/MIT/LIGO Lab) On 11 February, the Laser Interferometer Gravitational-Wave Observatory (LIGO) and Virgo collaborations published a historic paper in which they showed a gravitational signal emitted by the merger of two black holes. These results come after 20 years of hard work by a large collaboration of scientists operating the two LIGO observatories in the US. Barry Barish, Linde Professor of Physics, Emeritus at the California Institute of Technology and former Director of the Global Design Effort for the Internat...

  12. Strongly interacting Higgs bosons

    International Nuclear Information System (INIS)

    Appelquist, T.; Bernard, C.

    1980-01-01

    The sensitivity of present-energy weak interactions to a strongly interacting heavy-Higgs-boson sector is discussed. The gauged nonlinear sigma model, which is the limit of the linear model as the Higgs-boson mass goes to infinity, is used to organize and catalogue all possible heavy-Higgs-boson effects. As long as the SU(2)/sub L/ x SU(2)/sub R/ symmetry of the Higgs sector is preserved, these effects are found to be small, of the order of the square of the gauge coupling times logarithms (but not powers) of the Higgs-boson mass divided by the W mass. We work in the context of a simplified model with gauge group SU(2)/sub L/; the extension to SU(2)/sub L/ x U(1) is briefly discussed

  13. Limit analysis and design of containment vessels

    International Nuclear Information System (INIS)

    Save, M.

    1984-01-01

    In the introduction, the theory of plastic analysis of shells is briefly recalled. Minimum-volume design for assigned load factor at plastic collapse is then considered and optimality criteria are derived for plates and shells of continuously varying or piecewise-constant thickness. In the first part, containers made of metal are examined. Analytical and numerical limit analysis solutions and corresponding experimental results are considered for various types of vessels, including intersecting shells. Attention is given to experimental post-yield behavior. Some tests up to fracture are discussed. New theoretical and experimental results of limit analysis of stiffened cylindrical vessels are presented, in which reinforcing rings are treated as discrete structural element (no smearing out) and due account is taken of their strong curvature. Cases of collapse by instability under internal pressure are pointed out. Minimum-volume design of circular plates and cylindrical shells is then formulated and various examples are presented of sandwich and solid metal structures. Containers of piecewise-constant thickness are given particular attention. Available experimental evidence on minimum-volume design of plates and shells is reviewed and commented upon. The second part deals with reinforced concrete vessels. Cylindrical containers are studied, from both points of view of limit analysis and of limit design with minimum volume of reinforcement. The practical use of the latter solutions is discussed. A third part reviews other loading cases (including cyclic and impact loads) and gives indications on corresponding theories, formulations and solution methods. The last part is devoted to a discussion of the limitations of the methods presented, within the frame of the 'limit states' design philosophy, which is first briefly recalled. Considerations on further research in the field conclude the paper. (orig.)

  14. Emergency venting of pressure vessels

    International Nuclear Information System (INIS)

    Steinkamp, H.

    1995-01-01

    With the numerical codes developed for safety analysis the venting of steam vessel can be simulated. ATHLET especially is able to predict the void fraction depending on the vessel height. Although these codes contain a one-dimensional model they allow the description of complex geometries due to the detailed nodalization of the considered apparatus. In chemical reactors, however, the venting process is not only influenced by the flashing behaviour but additionally by the running chemical reaction in the vessel. Therefore the codes used for modelling have to consider the kinetics of the chemical reaction. Further multi-component systems and dissolving processes have to be regarded. In order to preduct the fluid- and thermodynamic process it could be helpful to use 3-dimensional codes in combination with the one-dimensional codes as used in nuclear industry to get a more detailed describtion of the running processes. (orig./HP)

  15. Development of Catamaran Fishing Vessel

    Directory of Open Access Journals (Sweden)

    A. Jamaluddin

    2010-11-01

    Full Text Available Multihull due to a couple of advantages has been the topic of extensive research work in naval architecture. In this study, a series of investigation of fishing vessel to save fuel energy was carried out at ITS. Two types of ship models, monohull (round bilge and hard chine and catamaran, a boat with two hulls (symmetrical and asymmetrical were developed. Four models were produced physically and numerically, tested (towing tank and simulated numerically (CFD code. The results of the two approaches indicated that the catamaran mode might have drag (resistance smaller than those of monohull at the same displacement. A layout of catamaran fishing vessel, proposed here, indicates the freedom of setting the deck equipments for fishing vessel.

  16. Determination of thermal and physical properties of port-wine stain lesions using pulsed photothermal radiometry

    Science.gov (United States)

    Nelson, J. Stuart; Jacques, Steven L.; Wright, William H.

    1992-06-01

    A method for quantitative characterization of port wine stain (PWS) is presented. Pulsed photothermal radiometry (PPTR) uses a non-invasive infrared radiometry system to measure changes in surface temperature induced by pulsed radiation. When a pulsed laser is used to irradiate a PWS, an initial temperature jump (T-jump) is seen due to the heating of the epidermis as a result of melanin absorption. Subsequently, heat generated in the subsurface blood vessels due to hemoglobin absorption is detected by PPTR as a delayed thermal wave as the heat diffuses toward the skin surface. The time delay and magnitude of the delayed PPTR signal indicate the depth and thickness of the PWS. In this report, we present an initial clinical study of PPTR measurements on PWS patients. Computer simulations of various classes of PWS illustrate how the PPTR signal depends on the concentration of epidermal melanin, and depth and thickness of the PWS. The goal of this research is to provide a means of characterizing PWS before initiating therapy, guiding laser dosimetry, and advising the patient as to the time course and efficacy of the planned protocol.

  17. 33 CFR 90.3 - Pushing vessel and vessel being pushed: Composite unit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pushing vessel and vessel being... HOMELAND SECURITY INLAND NAVIGATION RULES INLAND RULES: INTERPRETATIVE RULES § 90.3 Pushing vessel and vessel being pushed: Composite unit. Rule 24(b) of the Inland Rules states that when a pushing vessel and...

  18. 33 CFR 82.3 - Pushing vessel and vessel being pushed: Composite unit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pushing vessel and vessel being... HOMELAND SECURITY INTERNATIONAL NAVIGATION RULES 72 COLREGS: INTERPRETATIVE RULES § 82.3 Pushing vessel and vessel being pushed: Composite unit. Rule 24(b) of the 72 COLREGS states that when a pushing vessel and a...

  19. Weathering patinas on the medieval (S. XIV) stained glass windows of the Pedralbes Monastery (Barcelona, Spain).

    Science.gov (United States)

    Aulinas, Meritxell; Garcia-Valles, Maite; Gimeno, Domingo; Fernandez-Turiel, Jose Luis; Ruggieri, Flavia; Pugès, Montserrat

    2009-06-01

    contrast, weddellite is limited to the absence of thenardite and whewellite and to the external parts of the stained glass. Quartz is present in all the patinas independent of their location and color. Calcite also occurs in many samples. It appears in both color-type patinas and, in some cases, is associated to the presence of weddellite but not to whewellite and/or thenardite. Glass composition together with environmental conditions and location of the patinas (internal or external parts of the stained glass window), as well as the provenance of the glass within the monastery, are the main factors that define the development of the new mineral phases. Moreover, the action of microorganisms, when present, can also strongly influence the development of some mineral phases. For example, the formation of calcite in the external parts of the stained glass (associated with the presence of oxalates) is related to the action of microorganisms. When calcite is formed in the internal parts of the glass and it is not associated with the presence of Ca-oxalates, an inorganic origin can be invoked. The presence of weddellite requires a very humid microenvironment with very little exposure to sunlight. In fact, this mineral phase has only been observed in the external parts of some glass located in the humid and shady side of the monastery. Whewellite (which only appears in the internal parts) needs a low degree of relative humidity. It has been observed that sulfur precipitating in basically one mineral phase (thenardite or gypsum) depends on the microenvironmental conditions of the moment and the glass composition. When thenardite occurs, it can be maintained that the original glass is of Na composition. The occurrence of quartz in all samples is interpreted as being due to the deposition of atmospheric particulate matter. The color of the patinas can be originated by different processes (presence of carotenes, organic pigmentation, atmospheric contamination, etc.). In the case of

  20. Evaluation of Papanicolaou stain for studying micronuclei in buccal cells under field conditions.

    Science.gov (United States)

    Ayyad, Sohair B A; Israel, Ebenezer; El-Setouhy, Maged; Nasr, Ghada Radwan; Mohamed, Mostafa K; Loffredo, Christopher A

    2006-01-01

    To compare Papanicolaou (Pap) and May-Grünwald Giemsa (MGG) stain as 2 techniques for staining for buccal mucosal cells to detect micronuclei (MN) infield studies. Eighty cytologic smears (2 per individual) were taken from the buccal mucosa of 40 cigarette smokers recruited at a rural village in Egypt. Forty smears were stained with Pap stain and 40 with MGG stain. All were assessed for cellularity and scored for MN. Pap stain was faster and easier to process and transport in the field study than was MGG stain. Regarding MGG smears, bacteria and cell debris masked the MN as compared to Pap smears, in which the fixative destroyed the bacteria and made the cell boundaries clearly demarcated. Using Pap stain, MN were seen easily in transparent cytoplasm. Pap stain is the preferred method infield studies for scoring and detecting MN in cells of buccal mucosa.

  1. Containment vessel design and practice

    International Nuclear Information System (INIS)

    Bangash, Y.

    1983-01-01

    The state of the art of analysis and design of the concrete containment vessels required for BWR and PWR is reviewed. A step-by-step critical appraisal of the existing work is given. Elastic, inelastic and cracking conditions under extreme loads are fully discussed. Problems associated with these structures are highlighted. A three-dimensional finite element analysis is included to cater for service, overload and dynamic cracking of such structures. Missile impact and seismic effects are included in this work. The second analysis is known as the limit state analysis, which is given to design such vessels for any kind of load. (U.K.)

  2. Stress analysis of pressure vessels

    International Nuclear Information System (INIS)

    Kim, B.K.; Song, D.H.; Son, K.H.; Kim, K.S.; Park, K.B.; Song, H.K.; So, J.Y.

    1979-01-01

    This interim report contains the results of the effort to establish the stress report preparation capability under the research project ''Stress analysis of pressure vessels.'' 1978 was the first year in this effort to lay the foundation through the acquisition of SAP V structural analysis code and a graphic terminal system for improved efficiency of using such code. Software programming work was developed in pre- and post processing, such as graphic presentation of input FEM mesh geometry and output deformation or mode shope patterns, which was proven to be useful when using the FEM computer code. Also, a scheme to apply fracture mechanics concept was developed in fatigue analysis of pressure vessels. (author)

  3. Vessel dilatation in coronary angiograms

    International Nuclear Information System (INIS)

    Hinterauer, L.; Goebel, N.

    1983-01-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment. (orig.) [de

  4. Vessel dilatation in coronary angiograms

    Energy Technology Data Exchange (ETDEWEB)

    Hinterauer, L.; Goebel, N.

    1983-11-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment.

  5. WITHDRAWN: Amnioinfusion for meconium-stained liquor in labour.

    Science.gov (United States)

    Hofmeyr, G Justus

    2009-01-21

    Amnioinfusion aims to prevent or relieve umbilical cord compression during labour by infusing a solution into the uterine cavity. It is also thought to dilute meconium when present in the amniotic fluid and so reduce the risk of meconium aspiration. However, it may be that the mechanism of effect is that it corrects oligohydramnios (reduced amniotic fluid), for which thick meconium staining is a marker. The objective of this review was to assess the effects of amnioinfusion for meconium-stained liquor on perinatal outcome. The Cochrane Pregnancy and Childbirth Group trials register (October 2001) and the Cochrane Controlled Trials Register (Issue 3, 2001) were searched. Randomised trials comparing amnioinfusion with no amnioinfusion for women in labour with moderate or thick meconium-staining of the amniotic fluid. Eligibility and trial quality were assessed by one reviewer. Twelve studies, most involving small numbers of participants, were included. Under standard perinatal surveillance, amnioinfusion was associated with a reduction in the following: heavy meconium staining of the liquor (relative risk 0.03, 95% confidence interval 0.01 to 0.15); variable fetal heart rate deceleration (relative risk 0.65, 95% confidence interval 0.49 to 0.88); and reduced caesarean section overall (relative risk 0.82, 95% confidence interval 0.69 to 1.97). No perinatal deaths were reported. Under limited perinatal surveillance, amnioinfusion was associated with a reduction in the following: meconium aspiration syndrome (relative risk 0.24, 95% confidence interval 0.12 to 0.48); neonatal hypoxic ischaemic encephalopathy (relative risk 0.07, 95% confidence interval 0.01 to 0.56) and neonatal ventilation or intensive care unit admission (relative risk 0.56, 95% confidence interval 0.39 to 0.79); there was a trend towards reduced perinatal mortality (relative risk 0.34, 95% confidence interval 0.11 to 1.06). Amnioinfusion is associated with improvements in perinatal outcome

  6. Machine vision system for automated detection of stained pistachio nuts

    Science.gov (United States)

    Pearson, Tom C.

    1995-01-01

    A machine vision system was developed to separate stained pistachio nuts, which comprise of about 5% of the California crop, from unstained nuts. The system may be used to reduce labor involved with manual grading or to remove aflatoxin contaminated product from low grade process streams. The system was tested on two different pistachio process streams: the bi- chromatic color sorter reject stream and the small nut shelling stock stream. The system had a minimum overall error rate of 14% for the bi-chromatic sorter reject stream and 15% for the small shelling stock stream.

  7. Weathering effects on materials from historical stained glass windows

    Directory of Open Access Journals (Sweden)

    García-Heras, M.

    2003-06-01

    Full Text Available A selection of materials (stained glasses, lead cames, support elements and putty from historical stained glass windows of different periods (13th-19th centuries have been studied. Optical microscopy, scanning electron microscopy, energy dispersive X-ray spectrometry and X-ray diffraction were used as characterization techniques. Degradation of historical stained glass windows is due to the particular chemical composition oftlie materials used for their production: stained glasses, lead network, metallic support elements and refilling putty. However, the presence of a given chemical composition is not the only factor involved in the degradation process. It is necessary the occurrence of other external factors that contribute to the development and progress of alteration problems in the materials mentioned above. The presence of gaseous pollution in the air produces a negative interaction with the surface of the stained glass windows materials. Firstly, the stained glasses and the grisailles begin a dealkalinisation process and a silica gel layer is formed during the early contact between the glasses and the wet environment. After that, insoluble salt deposits and corrosion crusts are formed as a consequence of a deeper chemical attack which results in a depolymerisation of the glass network. The lead cames and the metallic support elements are also altered by weathering. Such materials are oxidized and both pits and crusts appear on their surfaces. The transport of ions and other substances from the corrosion crusts of the metallic elements gives rise new deposits upon the stained glasses, which could intensify their own degradation processes. The putty experiments a noticeable shrinkage and cracking. Likewise, adverse environmental conditions favour the transport of putty substances towards the other materials of the stained glass window, thereby increasing the crusts thickness and adding elements that contribute to the total alteration of the

  8. Strong-interaction nonuniversality

    International Nuclear Information System (INIS)

    Volkas, R.R.; Foot, R.; He, X.; Joshi, G.C.

    1989-01-01

    The universal QCD color theory is extended to an SU(3) 1 direct product SU(3) 2 direct product SU(3) 3 gauge theory, where quarks of the ith generation transform as triplets under SU(3)/sub i/ and singlets under the other two factors. The usual color group is then identified with the diagonal subgroup, which remains exact after symmetry breaking. The gauge bosons associated with the 16 broken generators then form two massive octets under ordinary color. The interactions between quarks and these heavy gluonlike particles are explicitly nonuniversal and thus an exploration of their physical implications allows us to shed light on the fundamental issue of strong-interaction universality. Nonuniversality and weak flavor mixing are shown to generate heavy-gluon-induced flavor-changing neutral currents. The phenomenology of these processes is studied, as they provide the major experimental constraint on the extended theory. Three symmetry-breaking scenarios are presented. The first has color breaking occurring at the weak scale, while the second and third divorce the two scales. The third model has the interesting feature of radiatively induced off-diagonal Kobayashi-Maskawa matrix elements

  9. John Strong (1941 - 2006)

    CERN Multimedia

    Wickens, F

    Our friend and colleague John Strong was cruelly taken from us by a brain tumour on Monday 31st July, a few days before his 65th birthday John started his career working with a group from Westfield College, under the leadership of Ted Bellamy. He obtained his PhD and spent the early part of his career on experiments at Rutherford Appleton Laboratory (RAL), but after the early 1970s his research was focussed on experiments in CERN. Over the years he made a number of notable contributions to experiments in CERN: The Omega spectrometer adopted a system John had originally developed for experiments at RAL using vidicon cameras to record the sparks in the spark chambers; He contributed to the success of NA1 and NA7, where he became heavily involved in the electronic trigger systems; He was responsible for the second level trigger system for the ALEPH detector and spent five years leading a team that designed and built the system, which ran for twelve years with only minor interventions. Following ALEPH he tur...

  10. Stirring Strongly Coupled Plasma

    CERN Document Server

    Fadafan, Kazem Bitaghsir; Rajagopal, Krishna; Wiedemann, Urs Achim

    2009-01-01

    We determine the energy it takes to move a test quark along a circle of radius L with angular frequency w through the strongly coupled plasma of N=4 supersymmetric Yang-Mills (SYM) theory. We find that for most values of L and w the energy deposited by stirring the plasma in this way is governed either by the drag force acting on a test quark moving through the plasma in a straight line with speed v=Lw or by the energy radiated by a quark in circular motion in the absence of any plasma, whichever is larger. There is a continuous crossover from the drag-dominated regime to the radiation-dominated regime. In the crossover regime we find evidence for significant destructive interference between energy loss due to drag and that due to radiation as if in vacuum. The rotating quark thus serves as a model system in which the relative strength of, and interplay between, two different mechanisms of parton energy loss is accessible via a controlled classical gravity calculation. We close by speculating on the implicati...

  11. Axial vessel widening in arborescent monocots.

    Science.gov (United States)

    Petit, Giai; DeClerck, Fabrice A J; Carrer, Marco; Anfodillo, Tommaso

    2014-02-01

    Dicotyledons have evolved a strategy to compensate for the increase in hydraulic resistance to water transport with height growth by widening xylem conduits downwards. In monocots, the accumulation of hydraulic resistance with height should be similar, but the absence of secondary growth represents a strong limitation for the maintenance of xylem hydraulic efficiency during ontogeny. The hydraulic architecture of monocots has been studied but it is unclear how monocots arrange their axial vascular structure during ontogeny to compensate for increases in height. We measured the vessel lumina and estimated the hydraulic diameter (Dh) at different heights along the stem of two arborescent monocots, Bactris gasipaes (Kunth) and Guadua angustifolia (Kunth). For the former, we also estimated the variation in Dh along the leaf rachis. Hydraulic diameter increased basally from the stem apex to the base with a scaling exponent (b) in the range of those reported for dicot trees (b = 0.22 in B. gasipaes; b = 0.31 and 0.23 in G. angustifolia). In B. gasipaes, vessels decrease in Dh from the stem's centre towards the periphery, an opposite pattern compared with dicot trees. Along the leaf rachis, a pattern of increasing Dh basally was also found (b = 0.13). The hydraulic design of the monocots studied revealed an axial pattern of xylem conduits similar to those evolved by dicots to compensate and minimize the negative effect of root-to-leaf length on hydrodynamic resistance to water flow.

  12. Visualisation of plastid outgrowths in potato (Solanum tuberosum L.) tubers by carboxyfluorescein diacetate staining.

    Science.gov (United States)

    Borucki, Wojciech; Bederska, Magdalena; Sujkowska-Rybkowska, Marzena

    2015-05-01

    We describe two types of plastid outgrowths visualised in potato tubers after carboxyfluorescein diacetate staining. Probable esterase activity of the outgrowths has been demonstrated for the first time ever. Plastid outgrowths were observed in the phelloderm and storage parenchyma cells of red potato (S. tuberosum L. cv. Rosalinde) tubers after administration of carboxyfluorescein diacetate stain. Endogenous esterases cleaved off acetic groups to release membrane-unpermeable green fluorescing carboxyfluorescein which accumulated differentially in particular cell compartments. The intensive green fluorescence of carboxyfluorescein exhibited highly branched stromules (stroma-filled plastid tubular projections of the plastid envelope) and allowed distinguishing them within cytoplasmic strands of the phelloderm cells. Stromules (1) were directed towards the nucleus or (2) penetrated the whole cells through the cytoplasmic bands of highly vacuolated phelloderm cells. Those directed towards the nucleus were flattened and adhered to the nuclear envelope. Stromule-like interconnections between two parts of the same plastids (isthmuses) were also observed. We also documented the formation of another type of the stroma-filled plastid outgrowths, referred to here as protrusions, which differed from previously defined stromules in both morphology and esterase activity. Unlike stromules, the protrusions were found to be associated with developmental processes leading to starch accumulation in the storage parenchyma cells. These results strongly suggest that stromules and protrusions exhibit esterase activity. This has been demonstrated for the first time. Morphological and biochemical features as well as possible functions of stromules and protrusions are discussed below.

  13. Immunogold staining procedure for the localisation of regulatory peptides.

    Science.gov (United States)

    Varndell, I M; Tapia, F J; Probert, L; Buchan, A M; Gu, J; De Mey, J; Bloom, S R; Polak, J M

    1982-01-01

    The use of protein A- and IgG-conjugated colloidal gold staining methods for the immuno-localisation of peptide hormones and neurotransmitters at light- and electron microscope level are described and discussed. Bright-field and dark-ground illumination modes have been used to visualise the gold-labelled antigenic sites at the light microscope level. Immunogold staining procedures at the ultrastructural level using region-specific antisera have been adopted to localise specific molecular forms of peptides including gastrin (G17 and G34), glucagon and pro-glucagon, insulin and pro-insulin, in normal tissue and in tumours of the gastroenteropancreatic system. Similar methods have been used to demonstrate the heterogeneity of p-type nerves in the enteric nervous system. Vasoactive intestinal polypeptide (VIP) has been localised to granular sites (mean +/- S.D. granule diameter = 98 +/- 19 nm) in nerve terminals of the enteric plexuses and in tumour cells of diarrhoeogenic VIP-producing neoplasias (mean +/- S.D. granule diameter = 126 +/- 37 nm) using immunogold procedures applied to ultraviolet-cured ultrathin sections. Co-localisation of amines and peptides in carotid body type I cells and in chromaffin cells of normal adrenal medulla and phaeochromocytomas has also been demonstrated. Advantages of the immunogold procedures over alternative immunocytochemical techniques are discussed.

  14. Authenticity screening of stained glass windows using optical spectroscopy

    Science.gov (United States)

    Meulebroeck, Wendy; Wouters, Hilde; Nys, Karin; Thienpont, Hugo

    2016-11-01

    Civilized societies should safeguard their heritage as it plays an important role in community building. Moreover, past technologies often inspire new technology. Authenticity is besides conservation and restoration a key aspect in preserving our past, for example in museums when exposing showpieces. The classification of being authentic relies on an interdisciplinary approach integrating art historical and archaeological research complemented with applied research. In recent decades analytical dating tools are based on determining the raw materials used. However, the traditional applied non-portable, chemical techniques are destructive and time-consuming. Since museums oftentimes only consent to research actions which are completely non-destructive, optical spectroscopy might offer a solution. As a case-study we apply this technique on two stained glass panels for which the 14th century dating is nowadays questioned. With this research we were able to identify how simultaneous mapping of spectral signatures measured with a low cost optical spectrum analyser unveils information regarding the production period. The significance of this research extends beyond the re-dating of these panels to the 19th century as it provides an instant tool enabling immediate answering authenticity questions during the conservation process of stained glass, thereby providing the necessary data for solving deontological questions about heritage preservation.

  15. Color stability and staining of silorane after prolonged chemical challenges

    DEFF Research Database (Denmark)

    de Jesus, Vivian CBR; Martinelli, Nata Luiz; Poli-Frederico, Regina Célia

    Objectives: The purpose of this study was to investigate the effect of prolonged chemical challenges on color stability and staining susceptibility of a silorane-based composite material when compared to methacrylate-based composites. Methods: Cylindrical specimens (n=24) were fabricated from...... methacrylate (Filtek Z250, 3M ESPE; Filtek Z350XT, 3M ESPE; Master Fill, Biodinâmica) or silorane-based (Filtek P90, 3M ESPE) composite materials. Initial color was registered in a spectrophotometer. Specimens were divided in four groups and individually stored at 37°C in 0.02N citric acid, 0.02N phosphoric...... acid, 75% ethanol or distilled water (control) for 7, 14, 21, and 180 days, when new measurements were performed. A staining test was performed (n=12) after 21 days of chemical challenge by immersion in coffee during 3 weeks at 37°C. Color changes (¿E) were characterized using the CIEL*a*b* color...

  16. Analysis of surface stains on modern gold coins

    Energy Technology Data Exchange (ETDEWEB)

    Corregidor, V., E-mail: vicky.corregidor@itn.pt [Instituto Tecnológico e Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, E.N. 10, 2686-953 Sacavém (Portugal); CFNUL, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Alves, L.C. [Instituto Tecnológico e Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, E.N. 10, 2686-953 Sacavém (Portugal); CFNUL, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Cruz, J. [Instituto Tecnológico e Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, E.N. 10, 2686-953 Sacavém (Portugal); CFNUL, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Dep. Física, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-216 Caparica (Portugal)

    2013-07-01

    It is a mandatory practice in the European Mint Houses to provide a certificate of guarantee of their products specially when issuing commemorative gold or silver coins. This practise should assure satisfaction and trust both for the mint house and for the demanding numismatic collector. For these reasons the Mint Houses follow a strict quality control in all the production steps in order to ensure a no-defect, fully supervised output. In spite of all the undertaken precautions, different surface stains with diverse origin on gold coins recently minted in Europe were observed. Those were compositionally studied by means of IBA techniques at the end-stage nuclear microprobe installed at IST/ITN. From this study it was possible to identify several possible sources for these stains. The presence of defects at the surface of these commemorative coins address the need of improving the quality control system and the results here presented point out where these improvements should occur, in order to reduce/eliminate them and give the customer a product that with time probably will be revalued.

  17. Color stability of ceramic brackets immersed in potentially staining solutions.

    Science.gov (United States)

    Guignone, Bruna Coser; Silva, Ludimila Karsbergen; Soares, Rodrigo Villamarim; Akaki, Emilio; Goiato, Marcelo Coelho; Pithon, Matheus Melo; Oliveira, Dauro Douglas

    2015-01-01

    To assess the color stability of five types of ceramic brackets after immersion in potentially staining solutions. Ninety brackets were divided into 5 groups (n = 18) according to brackets commercial brands and the solutions in which they were immersed (coffee, red wine, coke and artificial saliva). The brackets assessed were Transcend (3M/Unitek, Monrovia, CA, USA), Radiance (American Orthodontics, Sheboygan, WI, USA), Mystique (GAC International Inc., Bohemia, NY, USA) and Luxi II (Rocky Mountain Orthodontics, Denver, CO, USA). Chromatic changes were analyzed with the aid of a reflectance spectrophotometer and by visual inspection at five specific time intervals. Assessment periods were as received from the manufacturer (T0), 24 hours (T1), 72 hours (T2), as well as 7 days (T3) and 14 days (T4) of immersion in the aforementioned solutions. Results were submitted to statistical analysis with ANOVA and Bonferroni correction, as well as to a multivariate profile analysis for independent and paired samples with significance level set at 5%. The duration of the immersion period influenced color alteration of all tested brackets, even though these changes could not always be visually observed. Different behaviors were observed for each immersion solution; however, brackets immersed in one solution progressed similarly despite minor variations. Staining became more intense over time and all brackets underwent color alterations when immersed in the aforementioned solutions.

  18. Stained glasses under the nuclear microprobe: A window into history

    Energy Technology Data Exchange (ETDEWEB)

    Vilarigues, M. [Dep. de Conservacao e Restauro and R and D Unit Vidro e da Ceramica Para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal)], E-mail: mgv@fct.unl.pt; Fernandes, P. [Dep. de Conservacao e Restauro and R and D Unit Vidro e da Ceramica Para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal); Alves, L.C.; Silva, R.C. da [Dep. Fisica, LFI, ITN, E.N.10, 2686-953 Sacavem (Portugal)

    2009-06-15

    Stained glass fragments from the 15th, 16th and 20th centuries, belonging to Mosteiro de Santa Maria da Vitoria, Batalha (Portugal), were characterised non-destructively in a nuclear microprobe. The work aimed at finding the composition of the glasses and glass paintings and relating these with the corresponding production periods. The elemental compositions of the glass fragments were obtained by means of scanning micro-beam Particle Induced X-ray Emission ({mu}-PIXE) spectrometry in selected cross-sections. These were complemented by micro X-Ray fluorescence spectrometry. Characterisation of colour was performed by optical absorption spectroscopy in the UV-vis range, while the corrosion products were identified by optical microscopy and {mu}-FTIR (Fourier Transform Infra Red) spectroscopy in combination with the data generated by {mu}-PIXE. Nuclear microprobe analysis allowed unveiling the compositions and structures, in particular of glass paintings and corrosion products. While it is not surprising that Fe, Cu and Pb were the main elements identified in the grisaille paintings of all studied periods, as well as Ag and Cu found in the glasses decorated with yellow silver painting, their distribution gave important clues on the materials and techniques used to manufacture these stained glasses. Furthermore, it allowed establishing a definite relation between the compositions found and the periods of production, with the added bonus of correctly reassigning the manufacturing period of some samples.

  19. Color stability of ceramic brackets immersed in potentially staining solutions

    Directory of Open Access Journals (Sweden)

    Bruna Coser Guignone

    2015-08-01

    Full Text Available OBJECTIVE: To assess the color stability of five types of ceramic brackets after immersion in potentially staining solutions.METHODS: Ninety brackets were divided into 5 groups (n = 18 according to brackets commercial brands and the solutions in which they were immersed (coffee, red wine, coke and artificial saliva. The brackets assessed were Transcend (3M/Unitek, Monrovia, CA, USA, Radiance (American Orthodontics, Sheboygan, WI, USA, Mystique (GAC International Inc., Bohemia, NY, USA and Luxi II (Rocky Mountain Orthodontics, Denver, CO, USA. Chromatic changes were analyzed with the aid of a reflectance spectrophotometer and by visual inspection at five specific time intervals. Assessment periods were as received from the manufacturer (T0, 24 hours (T1, 72 hours (T2, as well as 7 days (T3 and 14 days (T4 of immersion in the aforementioned solutions. Results were submitted to statistical analysis with ANOVA and Bonferroni correction, as well as to a multivariate profile analysis for independent and paired samples with significance level set at 5%.RESULTS: The duration of the immersion period influenced color alteration of all tested brackets, even though these changes could not always be visually observed. Different behaviors were observed for each immersion solution; however, brackets immersed in one solution progressed similarly despite minor variations.CONCLUSIONS: Staining became more intense over time and all brackets underwent color alterations when immersed in the aforementioned solutions.

  20. Coproduction of detergent compatible bacterial enzymes and stain removal evaluation.

    Science.gov (United States)

    Niyonzima, Francois N; More, Sunil S

    2015-10-01

    Most of the detergents that are presently produced contain the detergent compatible enzymes to improve and accelerate the washing performance by removing tough stains. The process is environment friendly as the use of enzymes in the detergent formulation reduces the utilization of toxic detergent constituents. The current trend is to use the detergent compatible enzymes that are active at low and ambient temperature in order to save energy and maintain fabric quality. As the detergent compatible bacterial enzymes are used together in the detergent formulation, it is important to co-produce the detergent enzymes in a single fermentation medium as the enzyme stability is assured, and production cost gets reduced enormously. The review reports on the production, purification, characterization and application of detergent compatible amylases, lipases, and proteases are available. However, there is no specific review or minireview on the concomitant production of detergent compatible amylases, lipases, and proteases. In this minireview, the coproduction of detergent compatible enzymes by bacterial species, enzyme stability towards detergents and detergent components, and stain release analysis were discussed. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Structural analysis of the JT-60SA cryostat vessel body

    Energy Technology Data Exchange (ETDEWEB)

    Botija, José, E-mail: jose.botija@ciemat.es [Association EURATOM – CIEMAT, Avda. Complutense 40, 28040 Madrid (Spain); Alonso, Javier; Fernández, Pilar; Medrano, Mercedes; Ramos, Francisco; Rincon, Esther; Soleto, Alfonso [Association EURATOM – CIEMAT, Avda. Complutense 40, 28040 Madrid (Spain); Davis, Sam; Di Pietro, Enrico; Tomarchio, Valerio [Fusion for Energy, JT-60SA European Home Team, 85748 Garching bei Munchen (Germany); Masaki, Kei; Sakasai, Akira; Shibama, Yusuke [JAEA – Japan Atomic Energy Agency, Naka Fusion Institute, Ibaraki 311-0193 (Japan)

    2013-10-15

    Highlights: ► Structural analysis to validate the JT-60SA cryostat vessel body design. ► Design code ASME 2007 “Boiler and Pressure Vessel Code. Section VIII”. ► First buckling mode: load multiplier of 10.644, higher than the minimum factor 4.7. ► Elastic and elastic–plastic stress analysis meets ASME against plastic collapse. ► Bolted fasteners have been analyzed showing small gaps closed by strong welding. -- Abstract: The JT-60SA cryostat is a stainless steel vacuum vessel (14 m diameter, 16 m height) which encloses the Tokamak providing the vacuum environment (10{sup −3} Pa) necessary to limit the transmission of thermal loads to the components at cryogenic temperature. It must withstand both external atmospheric pressure during normal operation and internal overpressure in case of an accident. The paper summarizes the structural analyses performed in order to validate the JT-60SA cryostat vessel body design. It comprises several analyses: a buckling analysis to demonstrate stability under the external pressure; an elastic and an elastic–plastic stress analysis according to ASME VIII rules, to evaluate resistance to plastic collapse including localized stress concentrations; and, finally, a detailed analysis with bolted fasteners in order to evaluate the behavior of the flanges, assuring the integrity of the vacuum sealing welds of the cryostat vessel body.

  2. Grounding Damage to Conventional Vessels

    DEFF Research Database (Denmark)

    Lützen, Marie; Simonsen, Bo Cerup

    2003-01-01

    The present paper is concerned with rational design of conventional vessels with regard to bottom damage generated in grounding accidents. The aim of the work described here is to improve the design basis, primarily through analysis of new statistical data for grounding damage. The current regula...

  3. PLANNING VESSEL BODY SECTION PRODUCTION

    Directory of Open Access Journals (Sweden)

    A. G. Grivachevsky

    2015-01-01

    Full Text Available A problem of planning production of a vessel body section is considered. The problem is reduced to the classic Johnson’s tree-machine flow-shop scheduling problem. A genetic algorithm and computer experiment to compare efficiency of this algorithm and the algorithm of full enumeration are described.

  4. Pressure vessel and method therefor

    Science.gov (United States)

    Saunders, Timothy

    2017-09-05

    A pressure vessel includes a pump having a passage that extends between an inlet and an outlet. A duct at the pump outlet includes at least one dimension that is adjustable to facilitate forming a dynamic seal that limits backflow of gas through the passage.

  5. Commercial Passenger Fishing Vessel Fishery

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains the logbook data from U.S.A. Commercial Passenger Fishing Vessels (CPFV) fishing in the U.S.A. EEZ and in waters off of Baja California, from...

  6. Development of PWR pressure vessel steels

    International Nuclear Information System (INIS)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed

  7. Development of PWR pressure vessel steels

    Energy Technology Data Exchange (ETDEWEB)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed.

  8. Pressure vessel for nuclear reactor plant consisting of several pre-stressed cast pressure vessels

    International Nuclear Information System (INIS)

    Bodmann, E.

    1984-01-01

    Several cylindrical pressure vessel components made of pressure castings are arranged on a sector of a circle around the cylindrical cast pressure vessel for accommodating the helium cooled HTR. Each component pressure vessel is connected to the reactor vessel by a horizontal gas duct. The contact surfaces between reactor and component pressure vessel are in one plane. In the spaces between the individual component pressure vessels, there are supporting blocks made of cast iron, which are hollow and also have flat surfaces. With the reactor vessel and the component pressure vessels they form a disc-shaped connecting part below and above the gas ducts. (orig./PW)

  9. Background staining of visualization systems in immunohistochemistry: comparison of the Avidin-Biotin Complex system and the EnVision+ system.

    Science.gov (United States)

    Vosse, Bettine A H; Seelentag, Walter; Bachmann, Astrid; Bosman, Fred T; Yan, Pu

    2007-03-01

    The aim of this study was to evaluate specific immunostaining and background staining in formalin-fixed, paraffin-embedded human tissues with the 2 most frequently used immunohistochemical detection systems, Avidin-Biotin-Peroxidase (ABC) and EnVision+. A series of fixed tissues, including breast, colon, kidney, larynx, liver, lung, ovary, pancreas, prostate, stomach, and tonsil, was used in the study. Three monoclonal antibodies, 1 against a nuclear antigen (Ki-67), 1 against a cytoplasmic antigen (cytokeratin), and 1 against a cytoplasmic and membrane-associated antigen and a polyclonal antibody against a nuclear and cytoplasmic antigen (S-100) were selected for these studies. When the ABC system was applied, immunostaining was performed with and without blocking of endogenous avidin-binding activity. The intensity of specific immunostaining and the percentage of stained cells were comparable for the 2 detection systems. The use of ABC caused widespread cytoplasmic and rare nuclear background staining in a variety of normal and tumor cells. A very strong background staining was observed in colon, gastric mucosa, liver, and kidney. Blocking avidin-binding capacity reduced background staining, but complete blocking was difficult to attain. With the EnVision+ system no background staining occurred. Given the efficiency of the detection, equal for both systems or higher with EnVision+, and the significant background problem with ABC, we advocate the routine use of the EnVision+ system.

  10. Comparison of Gram and Kopeloff stains in the diagnosis of bacterial vaginosis in pregnancy.

    Science.gov (United States)

    Libman, Michael D; Kramer, Michael; Platt, Robert

    2006-03-01

    Bacterial vaginosis (BV) is commonly diagnosed by using the Nugent score, a semiquantitative scoring system to evaluate bacterial morphotypes on Gram stain of vaginal secretions. Some authors have suggested using the Kopeloff modification of the Gram stain. Asymptomatic BV in pregnancy has been associated with adverse outcomes. We performed both stains on simultaneously collected vaginal smears from 2652 women at 24-26 weeks of gestation. Gram staining gave significantly higher (more abnormal) Nugent scores than Kopeloff staining. Compared to the Kopeloff stain, the number of specimens graded as indeterminate or consistent with BV by Gram stain increased by 29% (469 versus 364, Pstaining was significantly better than Gram staining (agreement=74% versus 63%, intraclass correlation coefficient=0.87 versus 0.79, P<.05, 95% confidence intervals 0.85-0.89 and 0.75-0.82, respectively).

  11. Effectiveness of clean-up procedures on stain susceptibility of different orthodontic adhesives

    Directory of Open Access Journals (Sweden)

    Swati Pundlik Mane

    2014-01-01

    Conclusion: Chemical-cure adhesive showed higher stain susceptibility than light-cure adhesive in all clean-up procedures. Both adhesives would show less stain susceptibility with polishing step with rubber cup and pumice.

  12. Improved Nissl method to stain formaldehyde or glutaraldehyde-fixed material.

    Science.gov (United States)

    Böck, P

    1979-05-15

    Nissl staining of paraffin sections from formaldehyde- or glutaraldehyde-fixed specimens is significantly intensified when sections are kept in a 50% (w/v) aqueous solution of potassium metabisulfite before being stained by a conventional Nissl method.

  13. Maternal and fetal characteristics associated with meconium-stained amniotic fluid

    DEFF Research Database (Denmark)

    Balchin, Imelda; Whittaker, John C; Lamont, Ronald F

    2011-01-01

    To estimate the rates of meconium-stained amniotic fluid (AF) and adverse outcome in relation to gestational age and racial group, and to investigate the predictors of meconium-stained AF.......To estimate the rates of meconium-stained amniotic fluid (AF) and adverse outcome in relation to gestational age and racial group, and to investigate the predictors of meconium-stained AF....

  14. [Automated analysis of bacterial preparations manufactured on automatic heat fixation and staining equipment].

    Science.gov (United States)

    2012-01-01

    Heat fixation of preparations was made in the fixation bath designed by EMKO (Russia). Programmable "Emkosteiner" (EMKO, Russia) was used for trial staining. Reagents set Micko-GRAM-NITsF was applied for Gram's method of staining. It was demostrated that automatic smear fixation equipment and programmable staining ensure high-quality imaging (1% chromaticity variation) good enough for standardization of Gram's staining of microbial preparations.

  15. Indirect immunofluorescence staining of Chlamydia trachomatis inclusions in microculture plates with monoclonal antibodies.

    Science.gov (United States)

    Zapata, M; Chernesky, M; Mahony, J

    1984-06-01

    Indirect immunofluorescence (IF) staining, using a monoclonal antibody, detected two- to fourfold more inclusions than did iodine staining. Of 274 clinical specimens, 53 (19.3%) were positive by IF on passage 1 as compared with 33 (12%) by iodine staining (P less than 0.005). IF-stained inclusions in McCoy cells in the bottom of microculture wells were readily viewed with a long-focal-length objective at a magnification of 250 X.

  16. Indirect immunofluorescence staining of Chlamydia trachomatis inclusions in microculture plates with monoclonal antibodies.

    OpenAIRE

    Zapata, M; Chernesky, M; Mahony, J

    1984-01-01

    Indirect immunofluorescence (IF) staining, using a monoclonal antibody, detected two- to fourfold more inclusions than did iodine staining. Of 274 clinical specimens, 53 (19.3%) were positive by IF on passage 1 as compared with 33 (12%) by iodine staining (P less than 0.005). IF-stained inclusions in McCoy cells in the bottom of microculture wells were readily viewed with a long-focal-length objective at a magnification of 250 X.

  17. Diagnostic utility of melanin production by fungi: Study on tissue sections and culture smears with Masson-Fontana stain

    Directory of Open Access Journals (Sweden)

    Challa Sundaram

    2014-01-01

    Full Text Available Background: Dematiaceous fungi appear brown in tissue section due to melanin in their cell walls. When the brown color is not seen on routine H and E and culture is not available, differentiation of dematiaceous fungi from other fungi is difficult on morphology alone. Aims and Objective: To study if melanin production by dematiaceous fungi can help differentiate them from other types of fungi. Materials and Methods: Fifty tissue sections of various fungal infections and 13 smears from cultures of different species of fungi were stained with Masson Fontana stain to assess melanin production. The tissue sections included biopsies from 26 culture-proven fungi and 24 biopsies of filamentous fungi diagnosed on morphology alone with no culture confirmation. Results: All culture-proven dematiaceous fungi and Zygomycetes showed strong positivity in sections and culture smears. Aspergillus sp showed variable positivity and intensity. Cryptococcus neoformans showed strong positivity in tissue sections and culture smears. Tissue sections of septate filamentous fungi (9/15, Zygomycetes (4/5, and fungi with both hyphal and yeast morphology (4/4 showed positivity for melanin. The septate filamentous fungi negative for melanin were from biopsy samples of fungal sinusitis including both allergic and invasive fungal sinusitis and colonizing fungal balls. Conclusion: Melanin is produced by both dematiaceous and non-dematiaceous fungi. Masson-Fontana stain cannot reliably differentiate dematiaceous fungi from other filamentous fungi like Aspergillus sp; however, absence of melanin in the hyphae may be used to rule out dematiaceous fungi from other filamentous fungi. In the differential diagnosis of yeast fungi, Cryptococcus sp can be differentiated from Candida sp by Masson-Fontana stain in tissue sections.

  18. Conjugates of a Photoactivated Rhodamine with Biopolymers for Cell Staining

    Science.gov (United States)

    Zaitsev, Sergei Yu.; Shaposhnikov, Mikhail N.; Solovyeva, Daria O.; Solovyeva, Valeria V.; Rizvanov, Albert A.

    2014-01-01

    Conjugates of the photoactivated rhodamine dyes with biopolymers (proteins, polysaccharides, and nucleic acids) are important tools for microscopic investigation of biological tissue. In this study, a precursor of the photoactivated fluorescent dye (PFD) has been successfully used for staining of numerous mammalian cells lines and for conjugate formation with chitosan (“Chitosan-PFD”) and histone H1 (“Histone H1.3-PFD”). The intensive fluorescence has been observed after photoactivation of these conjugates inside cells (A431, HaCaT, HEK239, HBL-100, and MDCK). Developed procedures and obtained data are important for further application of novel precursors of fluorescent dyes (“caged” dyes) for microscopic probing of biological objects. Thus, the synthesized “Chitosan-PFD” and “Histone H1-PFD” have been successfully applied in this study for intracellular transport visualization by fluorescent microscopy. PMID:25383365

  19. Role of cytochemical staining in diagnosis of monocytic leukemia

    International Nuclear Information System (INIS)

    Wei Yan; Yan Chenhua; Shi Huilin; Liu Yanrong; Qiu Jingying; Jiang Bing; Wang Debing

    2005-01-01

    Objective: To explore the role of cytochemical staining in MIC(morphology ,immunology and cytogenetics) typing of acute monocytic leukemia (AML-M5) and acute myelomonocytic leukemia (AML-M4). Methods: The authors analyzed the characteristics of morphology, immunology and cytogenetics in 47 cases of diagnosed AML. Results: Eventually, they were diagnosed with MIC. There were 25 cases with AML-M5, 19 cases with AML-M4(consisted of 5 cases diagnosed AML-M4Eo), 2 cases with acute myeloid leukemia with t(8:21) and 1 case with T-ALL. Conclusions: During MIC typing of AML-M4 and AML-M5, the diagnostic value of morphology remains important, for immunophenotype, cytogenetics and morphology are interdependent. Immunophenotype and cytogenetics are necessary for improvement of the accuracy rate of diagnosis. (authors)

  20. PHACE syndrome misdiagnosed as a port-wine stain.

    Science.gov (United States)

    Thomson, Jason; Greig, Aina; Lloyd, Claire; Morrison, Danny; Flohr, Carsten

    2015-07-15

    We present the case of a boy born with a large macular, segmental vascular anomaly over the left face, initially diagnosed as a capillary malformation (port-wine stain) by the postnatal paediatric team. The vascular anomaly in the face then grew rapidly during the first few weeks of life and started to occlude the left eye, causing parental concerns about the infant's vision. A dermatological opinion established that the lesion was a segmental infantile haemangioma (IH). This, in combination with the posterior fossa malformation previously detected on antenatal scanning and confirmed by an MRI postnatally, satisfied the criteria for Posterior fossa abnormalities, Haemangiomas, Arterial abnormalities, Cardiac abnormalities and Eye abnormalities (PHACE) syndrome: a rare cutaneous neurovascular syndrome. This case highlights the diagnostic challenge posed by early phenotypes of haemangiomas as well as the importance of correctly diagnosing PHACE syndrome. 2015 BMJ Publishing Group Ltd.

  1. Surface discoloration of composite resins: Effects of staining and bleaching.

    Science.gov (United States)

    Poggio, Claudio; Beltrami, Riccardo; Scribante, Andrea; Colombo, Marco; Chiesa, Marco

    2012-09-01

    The purpose of this in vitro study was to evaluate surface discoloration of three microhybrid composite resins (Esthet•X HD, Clearfil AP-X, Gradia Direct) and five nanohybrid composite resins (Ceram•X, GC Kalore, G-aenial, Grandio, GrandioSO), after staining and bleaching procedures. The composite resins were polymerized with a curing light (Celalux II, Voco, Cuxhaven, Germany) into 160 silicon molds (6,4 mm in diameter and 2 mm in thickness) to obtain identical specimens. Twenty samples for each composite resin were prepared. The specimens were polished using an automated polishing machine with the sequence of 600-, 800-, 1000-grit abrasive paper under water irrigation. The specimens were immersed in tea and distilled water: the specimens were dipped for 20 min, once a day (every 24 h), for 14 days into the drinks. The specimens were then bleached with carbamide peroxide at 17% (Perfect Bleach-Voco). The color of specimens was measured with a spectrophotometer according to the CIE L(*)a(*)b(*) system after light-polymerization of composite resin specimens, after 7 days, after 14 days, and after bleaching. The color difference h index (DEab(*)) between each measurement was calculated. Statistical analysis was made using analysis of variance (ANOVA). All specimens showed a significant increase in staining with a similar trend and no significant differences between microhybrid and nanohybrid composite resins. After whitening procedures, materials tested showed both significant and unsignificant differences of the h index. Microhybrid and nanohybrid composite resins had similar in vitro surface discoloration in tea. After bleaching, discoloration was removed from some composite resins tested.

  2. Digital simulation of staining in histopathology multispectral images: enhancement and linear transformation of spectral transmittance.

    Science.gov (United States)

    Bautista, Pinky A; Yagi, Yukako

    2012-05-01

    Hematoxylin and eosin (H&E) stain is currently the most popular for routine histopathology staining. Special and/or immuno-histochemical (IHC) staining is often requested to further corroborate the initial diagnosis on H&E stained tissue sections. Digital simulation of staining (or digital staining) can be a very valuable tool to produce the desired stained images from the H&E stained tissue sections instantaneously. We present an approach to digital staining of histopathology multispectral images by combining the effects of spectral enhancement and spectral transformation. Spectral enhancement is accomplished by shifting the N-band original spectrum of the multispectral pixel with the weighted difference between the pixel's original and estimated spectrum; the spectrum is estimated using M transformed to the spectral configuration associated to its reaction to a specific stain by utilizing an N × N transformation matrix, which is derived through application of least mean squares method to the enhanced and target spectral transmittance samples of the different tissue components found in the image. Results of our experiments on the digital conversion of an H&E stained multispectral image to its Masson's trichrome stained equivalent show the viability of the method.

  3. A Comparison of Heat versus Methanol Fixation for Gram Staining Bacteria

    Science.gov (United States)

    Minnerath, Jeanne M.; Roland, Jenna M.; Rossi, Lucas C.; Weishalla, Steven R.; Wolf, Melissa M.

    2009-01-01

    Gram staining bacteria is a fundamental technique introduced in general biology and microbiology laboratory courses. Two common problems students encounter when Gram staining bacteria are (1) having a difficult time locating bacterial cells on the microscope slide and (2) over-decolorizing bacterial cells during the staining procedure such that…

  4. Age estimation of blood stains by hemoglobin derivative determination using reflectance spectroscopy

    NARCIS (Netherlands)

    Bremmer, Rolf H.; Nadort, Annemarie; van Leeuwen, Ton G.; van Gemert, Martin J. C.; Aalders, Maurice C. G.

    2011-01-01

    Blood stains can be crucial in reconstructing crime events. However, no reliable methods are currently available to establish the age of a blood stain on the crime scene. We show that determining the fractions of three hemoglobin derivatives in a blood stain at various ages enables relating these

  5. AFSC/FMA/Vessel Assessment Logging

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Vessels fishing trawl gear, vessels fishing hook-and-line and pot gear that are also greater than 57.5 feet overall, and shoreside and floating processing facilities...

  6. 2013 EPA Vessels General Permit (VGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Information for any vessel that submitted a Notice of Intent (NOI), Notice of Termination (NOT), or annual report under EPA's 2013 Vessel General Permit (VGP)....

  7. Interstitial Cells of Blood Vessels

    Directory of Open Access Journals (Sweden)

    Vladimír Pucovský

    2010-01-01

    Full Text Available Blood vessels are made up of several distinct cell types. Although it was originally thought that the tunica media of blood vessels was composed of a homogeneous population of fully differentiated smooth muscle cells, more recent data suggest the existence of multiple smooth muscle cell subpopulations in the vascular wall. One of the cell types contributing to this heterogeneity is the novel, irregularly shaped, noncontractile cell with thin processes, termed interstitial cell, found in the tunica media of both veins and arteries. While the principal role of interstitial cells in veins seems to be pacemaking, the role of arterial interstitial cells is less clear. This review summarises the knowledge of the functional and structural properties of vascular interstitial cells accumulated so far, offers hypotheses on their physiological role, and proposes directions for future research.

  8. The Vessel Schedule Recovery Problem

    DEFF Research Database (Denmark)

    Brouer, Berit Dangaard; Plum, Christian Edinger Munk; Vaaben, Bo

    Maritime transportation is the backbone of world trade and is accountable for around 3% of the worlds CO2 emissions. We present the Vessel Schedule Recovery Problem (VSRP) to evaluate a given disruption scenario and to select a recovery action balancing the trade off between increased bunker cons...... consumption and the impact on the remaining network and the customer service level. The model is applied to 4 real cases from Maersk Line. Solutions are comparable or superior to those chosen by operations managers. Cost savings of up to 58% may be achieved.......Maritime transportation is the backbone of world trade and is accountable for around 3% of the worlds CO2 emissions. We present the Vessel Schedule Recovery Problem (VSRP) to evaluate a given disruption scenario and to select a recovery action balancing the trade off between increased bunker...

  9. Lymphatic Vessel Density as Prognostic Factor in Breast Carcinoma: Relation to Clinico pathologic Parameters

    International Nuclear Information System (INIS)

    El-Gendi, S.; Abdel-Hadi, M.

    2009-01-01

    Angiogenesis and lymphangiogenesis are essential for breast cancer growth and progression. This study aimed at investigating lymphatic micro vessel density (LVD) and microvessel density (MVD) as prognostic markers in breast carcinoma. Forty breast carcinomas were immuno stained for D2-40, CD31 and VEGF. Median lymphatic and blood micro vessel densities, as well as VEGF expression, were related to each other and to clinico pathologic parameters including lymph node (Ln) status. The efficacy of haematoxylin and eosin (H and E) in detecting lymphatic vessel invasion (LVI) compared to D2-40 immunostaining was also investigated. D2-40 stained normal lymphatic endothelium and myoepithelial cells, but with different staining patterns. D2-40 LVD related significantly to CD31 counts (r=0.470; p=0.002), and LN metastasis (Mann-Whitney U=101.500; p=0.043); however, it did not relate to age, tumor grade, tumor size or LVI. D2-40 identified LVI in 3 more cases (7.5%) than those detected by H and E. VEGF was expressed in 85% of cases, and was significantly related to CD31 and D2-40 counts (p=0.033 and 0.007, respectively). In conclusion, D2-40 LVD showed a significant association with LN metastasis, and can be considered to segregate patients with positive from those with negative LNs. D2-40 enhances the detection of LVI relative to H and E staining reflecting a potential for lymphatic metastatic spread and possible poor prognosis

  10. Nuclear power plant pressure vessels. Inservice inspections

    International Nuclear Information System (INIS)

    1995-01-01

    The requirements for the planning and reporting of inservice inspections of nuclear power plant pressure vessels are presented. The guide specifically applies to inservice inspections of Safety class 1 and 2 nuclear power plant pressure vessels, piping, pumps and valves plus their supports and reactor pressure vessel internals by non- destructive examination methods (NDE). Inservice inspections according to the Pressure Vessel Degree (549/73) are discussed separately in the guide YVL 3.0. (4 refs.)

  11. Expanded Fermilab pressure vessel directory program

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, A.

    1983-01-01

    Several procedures have been written to manage the information pertaining to the vacuum tanks and pressure vessels for which the laboratory is responsible. These procedures have been named TANK1 for the vessels belonging to the Accelerator Division, TANK2 and TANK3 for the vessels belonging to the Research Division and to Technical Support respectively, and TANK4 for the vessels belonging to the Business Division. The operating procedures are otherwise identical in every respect.

  12. Expanded Fermilab pressure vessel directory program

    International Nuclear Information System (INIS)

    Tanner, A.

    1983-01-01

    Several procedures have been written to manage the information pertaining to the vacuum tanks and pressure vessels for which the laboratory is responsible. These procedures have been named TANK1 for the vessels belonging to the Accelerator Division, TANK2 and TANK3 for the vessels belonging to the Research Division and to Technical Support respectively, and TANK4 for the vessels belonging to the Business Division. The operating procedures are otherwise identical in every respect

  13. Vacuum vessel for plasma devices

    International Nuclear Information System (INIS)

    Yamada, Masao; Taguchi, Masami.

    1975-01-01

    Object: To permit effective utility of the space in the inner and outer sides of the container wall and also permit repeated assembly for use. Structure: Vacuum vessel wall sections are sealed together by means of welding bellows, and also flange portions formed at the end of the wall sections are coupled together by bolts and are sealed together with a seal ring and a seal cap secured by welding. (Nakamura, S.)

  14. Nd:YAG laser combined with gold nanorods for potential application in port-wine stains: an in vivo study

    Science.gov (United States)

    Xing, Linzhuang; Chen, Bin; Li, Dong; Wu, Wenjuan; Wang, Guoxiang

    2017-11-01

    Neodymium:yttrium aluminum garnet (Nd:YAG) lasers exhibit considerable potential for treating deeply buried port-wine stains. However, the application of Nd:YAG laser is limited by its weak absorption to blood. This in vivo study tested the efficacy and safety of utilizing thiol-terminated methoxypolyethylene glycol-modified gold nanorods (PEG-GNRs) to enhance the absorption of Nd:YAG laser to blood. Mouse mesentery and dorsal skinfold chamber (DSC) model were prepared to analyze the thermal responses of a single venule without anatomic structures, as well as blood vessels in the complex structure of the skin, to laser light. After the injection of 0.44 mg of PEG-GNRs, the required threshold density of laser energy for blood coagulation and complete vasoconstriction decreased from 24 to 18 J/cm2 in the mesentery model and from 36 to 31 J/cm2 in the DSC model. The laser pulse required for blood coagulation and complete vasoconstriction decreased by 67.75% and 62.25% on average in the mesentery model and by 67.55% and 54.45% on average in the DSC model. Histological and histochemical results confirmed that PEG-GNRs are nontoxic in the entire mouse life span. Therefore, combining PEG-GNRs with Nd:YAG laser may be effective and safe for inducing an obvious thermal response of blood vessels under low energy density and minimal pulse conditions.

  15. Reactor vessel head permanent shield

    International Nuclear Information System (INIS)

    Hankinson, M.F.; Leduc, R.J.; Richard, J.W.; Malandra, L.J.

    1989-01-01

    A nuclear reactor is described comprising: a nuclear reactor pressure vessel closure head; control rod drive mechanisms (CRDMs) disposed within the closure head so as to project vertically above the closure head; cooling air baffle means surrounding the control rod drive mechanisms for defining cooling air paths relative to the control rod drive mechanisms; means defined within the periphery of the closure head for accommodating fastening means for securing the closure head to its associated pressure vessel; lifting lugs fixedly secured to the closure head for facilitating lifting and lowering movements of the closure head relative to the pressure vessel; lift rods respectively operatively associated with the plurality of lifting lugs for transmitting load forces, developed during the lifting and lowering movements of the closure head, to the lifting lugs; upstanding radiation shield means interposed between the cooling air baffle means and the periphery of the enclosure head of shielding maintenance personnel operatively working upon the closure head fastening means from the effects of radiation which may emanate from the control rod drive mechanisms and the cooling air baffle means; and connecting systems respectively associated with each one of the lifting lugs and each one of the lifting rods for connecting each one of the lifting rods to a respective one of each one of the lifting lugs, and for simultaneously connecting a lower end portion of the upstanding radiation shield means to each one of the respective lifting lugs

  16. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-09-01

    A technical demonstration was successfully completed of simulated reactor vessel sectioning using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in. layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel; air arc gouging was selected to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. Three sectioning operations were demonstrated. For all three, the operating parameters were the same; but the position of the sample was varied. For the first cut, the sample was placed in a horizontal position, and it was successfully severed from the SS side. For the second cut, the sample was turned over and cut from the carbon steel side. Cutting from the carbon steel side has the advantages of cost reduction

  17. 33 CFR 151.1512 - Vessel safety.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Vessel safety. 151.1512 Section... River § 151.1512 Vessel safety. Nothing in this subpart relieves the master of the responsibility for ensuring the safety and stability of the vessel or the safety of the crew and passengers, or any other...

  18. Reactor vessel supported by flexure member

    International Nuclear Information System (INIS)

    Crawford, J.D.; Pankow, B.

    1975-01-01

    A description is given of a reactor pressure vessel which is provided with vertical support means in the form of circumferentially spaced columns upon which the vessel is mounted. The columns are adapted to undergo flexure in order to accommodate the thermally induced displacements experienced by the vessel during operational transients

  19. 19 CFR 4.97 - Salvage vessels.

    Science.gov (United States)

    2010-04-01

    ... United States and Great Britain ‘concerning reciprocal rights for United States and Canada in the... meaning of this statute. (e) A Mexican vessel may engage in a salvage operation on a Mexican vessel in any territorial waters of the United States in which Mexican vessels are permitted to conduct such operations by...

  20. Model tests for prestressed concrete pressure vessels

    International Nuclear Information System (INIS)

    Stoever, R.

    1975-01-01

    Investigations with models of reactor pressure vessels are used to check results of three dimensional calculation methods and to predict the behaviour of the prototype. Model tests with 1:50 elastic pressure vessel models and with a 1:5 prestressed concrete pressure vessel are described and experimental results are presented. (orig.) [de

  1. 50 CFR 648.4 - Vessel permits.

    Science.gov (United States)

    2010-10-01

    ... carrying passengers for hire. (8) Atlantic bluefish vessels. (i) Commercial. Any vessel of the United... lands Atlantic bluefish in or from the EEZ in excess of the recreational possession limit specified at § 648.164 must have been issued and carry on board a valid commercial bluefish vessel permit. (ii) Party...

  2. Captopril improves tumor nanomedicine delivery by increasing tumor blood perfusion and enlarging endothelial gaps in tumor blood vessels.

    Science.gov (United States)

    Zhang, Bo; Jiang, Ting; Tuo, Yanyan; Jin, Kai; Luo, Zimiao; Shi, Wei; Mei, Heng; Hu, Yu; Pang, Zhiqing; Jiang, Xinguo

    2017-12-01

    Poor tumor perfusion and unfavorable vessel permeability compromise nanomedicine drug delivery to tumors. Captopril dilates blood vessels, reducing blood pressure clinically and bradykinin, as the downstream signaling moiety of captopril, is capable of dilating blood vessels and effectively increasing vessel permeability. The hypothesis behind this study was that captopril can dilate tumor blood vessels, improving tumor perfusion and simultaneously enlarge the endothelial gaps of tumor vessels, therefore enhancing nanomedicine drug delivery for tumor therapy. Using the U87 tumor xenograft with abundant blood vessels as the tumor model, tumor perfusion experiments were carried out using laser Doppler imaging and lectin-labeling experiments. A single treatment of captopril at a dose of 100 mg/kg significantly increased the percentage of functional vessels in tumor tissues and improved tumor blood perfusion. Scanning electron microscopy of tumor vessels also indicated that the endothelial gaps of tumor vessels were enlarged after captopril treatment. Immunofluorescence-staining of tumor slices demonstrated that captopril significantly increased bradykinin expression, possibly explaining tumor perfusion improvements and endothelial gap enlargement. Additionally, imaging in vivo, imaging ex vivo and nanoparticle distribution in tumor slices indicated that after a single treatment with captopril, the accumulation of 115-nm nanoparticles in tumors had increased 2.81-fold with a more homogeneous distribution pattern in comparison to non-captopril treated controls. Finally, pharmacodynamics experiments demonstrated that captopril combined with paclitaxel-loaded nanoparticles resulted in the greatest tumor shrinkage and the most extensive necrosis in tumor tissues among all treatment groups. Taken together, the data from the present study suggest a novel strategy for improving tumor perfusion and enlarging blood vessel permeability simultaneously in order to improve

  3. Methyl green-pyronin Y staining of nucleic acids: studies on the effects of staining time, dye composition and diffusion rates

    DEFF Research Database (Denmark)

    Prentø, P; Lyon, H O

    2003-01-01

    individually, simultaneously and sequentially. The results are presented as color charts approximating the observed staining patterns using a computerized palette. Our results indicate unequivocally that the differential staining is not time-dependent, but that it is dictated by the relative concentrations...

  4. Clinical utility of an automated instrument for gram staining single slides.

    Science.gov (United States)

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-06-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.

  5. Clinical Utility of an Automated Instrument for Gram Staining Single Slides ▿

    Science.gov (United States)

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-01-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis. PMID:20410348

  6. Integrating Multiple Autonomous Underwater Vessels, Surface Vessels and Aircraft into Oceanographic Research Vessel Operations

    Science.gov (United States)

    McGillivary, P. A.; Borges de Sousa, J.; Martins, R.; Rajan, K.

    2012-12-01

    Autonomous platforms are increasingly used as components of Integrated Ocean Observing Systems and oceanographic research cruises. Systems deployed can include gliders or propeller-driven autonomous underwater vessels (AUVs), autonomous surface vessels (ASVs), and unmanned aircraft systems (UAS). Prior field campaigns have demonstrated successful communication, sensor data fusion and visualization for studies using gliders and AUVs. However, additional requirements exist for incorporating ASVs and UASs into ship operations. For these systems to be optimally integrated into research vessel data management and operational planning systems involves addressing three key issues: real-time field data availability, platform coordination, and data archiving for later analysis. A fleet of AUVs, ASVs and UAS deployed from a research vessel is best operated as a system integrated with the ship, provided communications among them can be sustained. For this purpose, Disruptive Tolerant Networking (DTN) software protocols for operation in communication-challenged environments help ensure reliable high-bandwidth communications. Additionally, system components need to have considerable onboard autonomy, namely adaptive sampling capabilities using their own onboard sensor data stream analysis. We discuss Oceanographic Decision Support System (ODSS) software currently used for situational awareness and planning onshore, and in the near future event detection and response will be coordinated among multiple vehicles. Results from recent field studies from oceanographic research vessels using AUVs, ASVs and UAS, including the Rapid Environmental Picture (REP-12) cruise, are presented describing methods and results for use of multi-vehicle communication and deliberative control networks, adaptive sampling with single and multiple platforms, issues relating to data management and archiving, and finally challenges that remain in addressing these technological issues. Significantly, the

  7. Triple –E Vessels: Tonnage Measurement and Suez Canal Dues Assessment

    Directory of Open Access Journals (Sweden)

    Elsayed Hussein Galall

    2015-08-01

    Full Text Available Container is growing faster than GDP, Shipping lines always attempt to augment efficiencyby reducing cost and by attracting larger volumes of containers. As a result rising containerfreight rates the lines have been driven to increase economic of scale, by building mega shipsand fewer mere efficient port calls. In 2011 Maersk line ordered up to 20 new “Triple- E “Class of container vessels deliversbetween 2013- 2015. These class of mega container vessels have its way through Suez Canal,other companies CMA, CGM also ordered this type of mega container vessels, in order toreach higher profits due to the achieved economics of scale It is believed that 20000 TEUcould be the next target size. Present mega container fleet and any future feasible potential vessel capacity expansionmore than 18000 TEU put Suez Canal route in strong competitive position. MeanwhilePanama Canal will not be able to handle vessels larger than 12600 TEU even after itsexpansion in 2015.

  8. Hirschsprung′s disease diagnosis: Comparison of immunohistochemical, hematoxilin and eosin staining

    Directory of Open Access Journals (Sweden)

    Memarzadeh Mehrdad

    2009-01-01

    Full Text Available Background : The diagnosis of Hirschsprung′s disease (HD is based on the absence of ganglion cells. In hemotoxilin and eosin (H and E as well as acetylcholine esterase staining there are limitations in the diagnosis of immature ganglion cells in neonates. Methods : In this prospective study, 54 biopsies taken from suspected HD patients (five mucosal specimens and 49 full thickness specimens were studied. In the laboratory, after preparing sections of paraffin embedded tissues, H and E staining slides were compared with immunohistochemical (IHC staining including: S100, NSE, CD117, CD56, Cathepsin D, Vimentin, BCL2, GFAP, Synaptophysin and chromogranin. Results : The study revealed 30 negative (absence of ganglion cells cases (55.5%, 17 positive cases (31.04% and seven suspected cases (12.9% of ganglion cells on the H and E staining. On IHC staining with CD56 and Cathepsin D, all of the 17 positive cases detected through H and E, were confirmed for having ganglion cells and out of 30 cases reported negative on H and E staining, 28(93.3% were reported negative and two (6.7% positive by IHC staining. Of the seven suspected cases H and E staining, IHC staining detectedganglion cells only in five slides; two remained negative. Conclusions : IHC staining using CD56 and Cathepsin D improved the accuracy of diagnosis in HD when used in addition to H and E staining technique, especially for negative or suspicious slides.

  9. Nucleic acid stains as indicators of Giardia muris viability following cyst inactivation.

    Science.gov (United States)

    Taghi-Kilani, R; Gyürék, L L; Millard, P J; Finch, G R; Belosevic, M

    1996-06-01

    A reliable viability assay for Giardia is required for the development of disinfection process design criteria and pathogen monitoring by water treatment utilities. Surveys of single-staining nucleic acid dyes (stain dead parasites only), and double-staining vital dye kits from Molecular Probes (stain live and dead parasites) were conducted to assess the viability of untreated, heat-killed, and chemically inactivated Giardia muris cysts. Nucleic acid staining results were compared to those of in vitro excystation and animal infectivity. Nucleic acid stain, designated as SYTO-9, was considered the best among the single-staining dyes for its ability to stain dead cysts brightly and its relatively slow decay rate of visible light emission following DNA binding. SYTO-9 staining was correlated to animal infectivity. A Live/Dead BacLight was found to be the better of 2 double-staining viability kits tested. Logarithmic survival ratios based on SYTO-9 and Live/Dead BacLight were compared to excystation and infectivity results for G. muris cysts exposed to ozone or free chlorine. The results indicate that SYTO-9 and Live/Dead BacLight staining is stable following treatment of cysts with chemical disinfectants.

  10. A Novel Contrast Stain for the Rapid Diagnosis of Pityriasis Versicolor: A Comparison of Chicago Sky Blue 6B Stain, Potassium Hydroxide Mount and Culture.

    Science.gov (United States)

    Lodha, Nikita; Poojary, Shital Amin

    2015-01-01

    The mycological study of pityriasis versicolor is usually done by potassium hydroxide (KOH) mount and culture. However, KOH mount lacks a color contrast and requires a trained eye to interpret, while culture is difficult to perform, time consuming and has low sensitivity. Chicago Sky Blue 6B (CSB) is a new contrast stain that highlights the fungal hyphae and spores, blue against a purplish background. This study was done to compare the utility of a novel contrast stain (CSB stain) with KOH mount and culture. Skin scrapings from the lesions of 100 clinically diagnosed cases of P. versicolor were subjected to (1) KOH mount and CSB stain for direct microscopic examination and (2) culture using Sabouraud's dextrose agar. The statistical analysis of CSB stain and culture was done using KOH mount as the reference method, as it is the most commonly performed and practical diagnostic test available for P. versicolor. An interrater reliability analysis using the Cohen's Kappa statistic was performed to determine consistency (agreement) among the different modalities. Direct microscopy with CSB stain, KOH mount and mycological culture showed positive results in 98 (98%), 92 (92%) and 56 (56%) patients, respectively. Using KOH mount as the reference method, CSB stain had a sensitivity of 100% which was significantly higher than culture (60.9%). Statistically significant fair agreement was found between CSB stain and KOH mount (94% with κ=0.38, P < 0.001). Negligible agreement was found between CSB stain and culture (66%, κ=0.199, P = 0.001) as well as between KOH mount and culture (64%, κ=0.051, P = 0.107). CSB staining of skin scrapings is the most sensitive method for the diagnosis of pityriasis versicolor. Due to the distinct contrast provided by CSB, it is easy to perform, rapid and qualitatively superior to KOH mount.

  11. A novel contrast stain for the rapid diagnosis of pityriasis versicolor: A comparison of Chicago Sky Blue 6B stain, potassium hydroxide mount and culture

    Directory of Open Access Journals (Sweden)

    Nikita Lodha

    2015-01-01

    Full Text Available Background: The mycological study of pityriasis versicolor is usually done by potassium hydroxide (KOH mount and culture. However, KOH mount lacks a color contrast and requires a trained eye to interpret, while culture is difficult to perform, time consuming and has low sensitivity. Chicago Sky Blue 6B (CSB is a new contrast stain that highlights the fungal hyphae and spores, blue against a purplish background. Aims and Objectives: This study was done to compare the utility of a novel contrast stain (CSB stain with KOH mount and culture. Materials and Methods: Skin scrapings from the lesions of 100 clinically diagnosed cases of P. versicolor were subjected to (1 KOH mount and CSB stain for direct microscopic examination and (2 culture using Sabouraud′s dextrose agar. The statistical analysis of CSB stain and culture was done using KOH mount as the reference method, as it is the most commonly performed and practical diagnostic test available for P. versicolor. An interrater reliability analysis using the Cohen′s Kappa statistic was performed to determine consistency (agreement among the different modalities. Observations and Results: Direct microscopy with CSB stain, KOH mount and mycological culture showed positive results in 98 (98%, 92 (92% and 56 (56% patients, respectively. Using KOH mount as the reference method, CSB stain had a sensitivity of 100% which was significantly higher than culture (60.9%. Statistically significant fair agreement was found between CSB stain and KOH mount (94% with κ=0.38, P < 0.001. Negligible agreement was found between CSB stain and culture (66%, κ=0.199, P = 0.001 as well as between KOH mount and culture (64%, κ=0.051, P = 0.107. Conclusion: CSB staining of skin scrapings is the most sensitive method for the diagnosis of pityriasis versicolor. Due to the distinct contrast provided by CSB, it is easy to perform, rapid and qualitatively superior to KOH mount.

  12. Amnioinfusion for meconium-stained liquor in labour.

    Science.gov (United States)

    Hofmeyr, G Justus; Xu, Hairong; Eke, Ahizechukwu C

    2014-01-23

    Amnioinfusion is thought to dilute meconium present in the amniotic fluid and so reduce the risk of meconium aspiration. To assess the effects of amnioinfusion for meconium-stained liquor on perinatal outcome. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (1 December 2013). Randomised trials comparing amnioinfusion with no amnioinfusion for women in labour with moderate or thick meconium staining of the amniotic fluid. Three review authors independently assessed eligibility and trial quality, and extracted data. Fourteen studies of variable quality (4435 women) are included.Subgroup analysis was performed for studies from settings with limited facilities to monitor the baby's condition during labour and intervene effectively, and settings with standard peripartum surveillance.Settings with standard peripartum surveillance: there was considerable heterogeneity for several outcomes. There was no significant reduction in the primary outcomes meconium aspiration syndrome, perinatal death or severe morbidity, and maternal death or severe morbidity. There was a reduction in caesarean sections (CSs) for fetal distress but not overall. Meconium below the vocal cords diagnosed by laryngoscopy was reduced, as was neonatal ventilation or neonatal intensive care unit admission, but there was no significant reduction in perinatal deaths or other morbidity. Planned sensitivity analysis excluding trials with greater risk of bias resulted in an absence of benefits for any of the outcomes studied.Settings with limited peripartum surveillance: three studies were included. In the amnioinfusion group there was a reduction in CS for fetal distress and overall; meconium aspiration syndrome (three studies, 1144 women; risk ratio (RR) 0.17, 95% confidence interval (CI) 0.05 to 0.52); perinatal mortality (three studies, 1151 women; RR 0.24, 95% CI 0.11 to 0.53) and neonatal ventilation or neonatal intensive care unit admission. In one of the studies, meconium

  13. Flaw distribution development from vessel ISI data

    International Nuclear Information System (INIS)

    Foulds, J.R.; Kennedy, E.L.; Basin, S.L.; Rosinski, S.T.

    1991-01-01

    Previous attempts to develop flaw distributions for use in the structural integrity evaluation of pressurized water reactor (PWR) vessels have aimed at the estimation of a ''generic'' distribution applicable to all vessels. In contrast, this paper describes the analysis of vessel-specific in-service inspection (ISI) data for the development of a flaw distribution reliably representative of the condition of the particular vessel inspected. The application of the methodology may be extended to other vessels, but has been primarily developed for PWR reactor vessels. For this study, the flaw data analyzed included data obtained from three recently performed PWR vessel ISIs and from laboratory inspection of selected weldment sections of the Midland reactor vessel. The variability in both the character of the reviewed data (size range of flaws, number of flaws) and the UT (ultrasonic test) inspection system performance identified a need for analyzing the inspection results on a vessel-, or data set-specific basis. For this purpose, traditional histogram-based methods were inadequate, and a new methodology that can accept a very small number of flaws (typical of vessel-specific ISI results) and that includes consideration of inspection system flaw detection reliability, flaw sizing accuracy and flaw detection threshold, was developed. Results of the application of the methodology to each of the four PWR reactor vessel cases studied are presented and discussed

  14. Comparison of staining of mitotic figures by haematoxylin and eosin-and crystal violet stains, in oral epithelial dysplasia and squamous cell carcinoma

    Directory of Open Access Journals (Sweden)

    Ankle Madhuri

    2007-01-01

    Full Text Available Mitosis of cells gives rise to tissue integrity. Defects during mitosis bring about abnormalities. Excessive proliferation of cells due to increased mitosis is one such outcome, which is the hallmark in precancer and cancer. The localization of proliferating cells or their precursors may not be obvious and easy. Establishing an easy way to distinguish these mitotic cells will help in grading and understanding their biological potential. Although immunohistochemistry is an advanced method in use, the cost and time factor makes it less feasible for many laboratories. Selective histochemical stains like toluidine blue, giemsa and crystal violet have been used in tissues including the developing brain, neural tissue and skin. Aim of the study: 1To compare the staining of mitotic cells in haematoxylin and eosin with that in crystal violet. 2To compare the number of mitotic figures present in normal oral mucosa, epithelial dysplasia and oral squamous cell carcinoma in crystal violet-stained sections with that in H and E-stained sections. Materials and Methods: Ten tissues of normal oral mucosa and 15 tissues each of oral epithelial dysplasia seen in tobacco-associated leukoplakia and squamous cell carcinoma were studied to evaluate the selectivity of 1% crystal violet for mitotic figures. The staining was compared with standard H and E staining. Statistical analysis was done using Man-Whitney U test. Results: A statistically significant increase in the mean mitotic count was observed in crystal violet-stained sections of epithelial dysplasia as compared to the H and E-stained sections ( p = 0.0327. A similar increase in the mitotic counts was noted in crystal violet-stained sections of oral squamous cell carcinoma as compared to the H and E-stained sections.( p = 0.0443. No significant difference was found in the mitotic counts determined in dysplasia or carcinoma by either the crystal violet ( p = 0.4429 or the H and E-staining techniques ( p = 0

  15. μCT of ex-vivo stained mouse hearts and embryos enables a precise match between 3D virtual histology, classical histology and immunochemistry

    Science.gov (United States)

    Larsson, Emanuel; Martin, Sabine; Lazzarini, Marcio; Tromba, Giuliana; Missbach-Guentner, Jeannine; Pinkert-Leetsch, Diana; Katschinski, Dörthe M.; Alves, Frauke

    2017-01-01

    The small size of the adult and developing mouse heart poses a great challenge for imaging in preclinical research. The aim of the study was to establish a phosphotungstic acid (PTA) ex-vivo staining approach that efficiently enhances the x-ray attenuation of soft-tissue to allow high resolution 3D visualization of mouse hearts by synchrotron radiation based μCT (SRμCT) and classical μCT. We demonstrate that SRμCT of PTA stained mouse hearts ex-vivo allows imaging of the cardiac atrium, ventricles, myocardium especially its fibre structure and vessel walls in great detail and furthermore enables the depiction of growth and anatomical changes during distinct developmental stages of hearts in mouse embryos. Our x-ray based virtual histology approach is not limited to SRμCT as it does not require monochromatic and/or coherent x-ray sources and even more importantly can be combined with conventional histological procedures. Furthermore, it permits volumetric measurements as we show for the assessment of the plaque volumes in the aortic valve region of mice from an ApoE-/- mouse model. Subsequent, Masson-Goldner trichrome staining of paraffin sections of PTA stained samples revealed intact collagen and muscle fibres and positive staining of CD31 on endothelial cells by immunohistochemistry illustrates that our approach does not prevent immunochemistry analysis. The feasibility to scan hearts already embedded in paraffin ensured a 100% correlation between virtual cut sections of the CT data sets and histological heart sections of the same sample and may allow in future guiding the cutting process to specific regions of interest. In summary, since our CT based virtual histology approach is a powerful tool for the 3D depiction of morphological alterations in hearts and embryos in high resolution and can be combined with classical histological analysis it may be used in preclinical research to unravel structural alterations of various heart diseases. PMID:28178293

  16. Primo vessel inside a lymph vessel emerging from a cancer tissue.

    Science.gov (United States)

    Lee, Sungwoo; Ryu, Yeonhee; Cha, Jinmyung; Lee, Jin-Kyu; Soh, Kwang-Sup; Kim, Sungchul; Lim, Jaekwan

    2012-10-01

    Primo vessels were observed inside the lymph vessels near the caudal vena cava of a rabbit and a rat and in the thoracic lymph duct of a mouse. In the current work we found a primo vessel inside the lymph vessel that came out from the tumor tissue of a mouse. A cancer model of a nude mouse was made with human lung cancer cell line NCI-H460. We injected fluorescent nanoparticles into the xenografted tumor tissue and studied their flow in blood, lymph, and primo vessels. Fluorescent nanoparticles flowed through the blood vessels quickly in few minutes, and but slowly in the lymph vessels. The bright fluorescent signals of nanoparticles disappeared within one hour in the blood vessels but remained much longer up to several hours in the case of lymph vessels. We found an exceptional case of lymph vessels that remained bright with fluorescence up to 24 hours. After detailed examination we found that the bright fluorescence was due to a putative primo vessel inside the lymph vessel. This rare observation is consistent with Bong-Han Kim's claim on the presence of a primo vascular system in lymph vessels. It provides a significant suggestion on the cancer metastasis through primo vessels and lymph vessels. Copyright © 2012. Published by Elsevier B.V.

  17. Intrapartum transcervical amnioinfusion for meconium-stained amniotic fluid.

    Science.gov (United States)

    Das, A K; Jana, N; Dasgupta, S; Samanta, B

    2007-06-01

    To assess the rates of cesarean deliveries and perinatal outcome following intrapartum transcervical amnioinfusion in women with meconium-stained amniotic fluid (MSAF) in a setting with no electronic fetal monitoring or specialized neonatal care. In this prospective comparative study with 150 women who were in labor and had MSAF, 50 of the women received a transcervical amnioinfusion and the remaining 100 women received standard care. The inclusion criteria were a pregnancy of at least 37 weeks' duration, a single live fetus in cephalic presentation, no major medical or obstetric complications, and no known fetal malformation. The amnioinfusion was performed with 1000 mL of normal saline solution through a red rubber catheter. Amnioinfusion was associated with a significant decrease in the incidence of low Apgar score (amnioinfusion than in the control group (24% vs. 48%; RR, 0.5; 95% CI, 0.29-0.85). There were no major complications related to amnioinfusion. Intrapartum amnioinfusion for MSAF is a simple, safe, effective, and inexpensive procedure feasible in settings where intrapartum monitoring is limited. It is associated with improved perinatal outcome and could lower cesarean delivery rates in low-resource countries.

  18. The challenges of analysing blood stains with hyperspectral imaging

    Science.gov (United States)

    Kuula, J.; Puupponen, H.-H.; Rinta, H.; Pölönen, I.

    2014-06-01

    Hyperspectral imaging is a potential noninvasive technology for detecting, separating and identifying various substances. In the forensic and military medicine and other CBRNE related use it could be a potential method for analyzing blood and for scanning other human based fluids. For example, it would be valuable to easily detect whether some traces of blood are from one or more persons or if there are some irrelevant substances or anomalies in the blood. This article represents an experiment of separating four persons' blood stains on a white cotton fabric with a SWIR hyperspectral camera and FT-NIR spectrometer. Each tested sample includes standardized 75 _l of 100 % blood. The results suggest that on the basis of the amount of erythrocytes in the blood, different people's blood might be separable by hyperspectral analysis. And, referring to the indication given by erythrocytes, there might be a possibility to find some other traces in the blood as well. However, these assumptions need to be verified with wider tests, as the number of samples in the study was small. According to the study there also seems to be several biological, chemical and physical factors which affect alone and together on the hyperspectral analyzing results of blood on fabric textures, and these factors need to be considered before making any further conclusions on the analysis of blood on various materials.

  19. Diffuse reflectance FTIR of stains on grit blasted metals

    Energy Technology Data Exchange (ETDEWEB)

    Powell, G.L.; Hallman, R.L. Jr.; Cox, R.L. [Oak Ridge Centers for Manufacturing Technologies, TN (United States)

    1997-08-09

    Diffuse reflectance mid-infrared Fourier transform (DRIFT) spectroscopy has been applied to the detection of oil contamination on grit-blasted metals. The object of this application is to detect and discriminate between silicone and hydrocarbon oil contamination at levels approaching 10 mg/m{sup 2}. A portable FTIR spectrometer with dedicated diffuse reflectance optics was developed for this purpose. Using translation devices positioned by instructions from the spectrometer operating system, images of macroscopic substrates were produced with millimeter spatial resolution. The pixels that comprise an image are each a full mid-infrared spectrum with excellent signal-to-noise, each determined as individual files and uniquely saved to disc. Reduced spectra amplitudes, based on peak height, area, or other chemometric techniques, mapped as a function of the spatial coordinates of the pixel are used to display the image. This paper demonstrates the application of the technique to the analysis of stains on grit-blasted metals, including the calibration of the method, the inspection of substrates, and the migration of oil contamination.

  20. Akreditasi Perpustakaan Perguruan Tinggi: Pengalaman Perpustakaan STAIN Kediri

    Directory of Open Access Journals (Sweden)

    Komarudin Komarudin

    2016-07-01

    Abstract; The importance of quality has been a concern of college library librarian. National Library has compiled standards can be used as a minimum level college library quality. A form of formal recognition of compliance with these standards is by accrediting library. Accreditation aims to improve accredited institution so useful to build a library quality. As stipulated by Law Decree(UU No. 43 of 2007 and Government Regulation (PPNo. 24 of 2014, the National Library has the National Library Accreditation Agency (LAP-N. Accredited certificate can obtain a library based on the number of components weighted values of service, cooperation, collection, organization of library materials, human resources, building / space and infrastructure, budget, library management and maintenance of library collection. The experience of STAIN Kediri library in carrying out the library accreditation including : make a plan of accreditation activities, form preparation team of accreditation, perform self assessments, set up support files, send a letter of application and data file support, assessment accreditation forms, prepare for site assessment and carry out the acreditation. The main thing is the accreditation is a culture of quality. Hope to obtain the best value of accreditation lies in the culture of quality.

  1. Development of a stained cell nuclei counting system

    Science.gov (United States)

    Timilsina, Niranjan; Moffatt, Christopher; Okada, Kazunori

    2011-03-01

    This paper presents a novel cell counting system which exploits the Fast Radial Symmetry Transformation (FRST) algorithm [1]. The driving force behind our system is a research on neurogenesis in the intact nervous system of Manduca Sexta or the Tobacco Hornworm, which was being studied to assess the impact of age, food and environment on neurogenesis. The varying thickness of the intact nervous system in this species often yields images with inhomogeneous background and inconsistencies such as varying illumination, variable contrast, and irregular cell size. For automated counting, such inhomogeneity and inconsistencies must be addressed, which no existing work has done successfully. Thus, our goal is to devise a new cell counting algorithm for the images with non-uniform background. Our solution adapts FRST: a computer vision algorithm which is designed to detect points of interest on circular regions such as human eyes. This algorithm enhances the occurrences of the stained-cell nuclei in 2D digital images and negates the problems caused by their inhomogeneity. Besides FRST, our algorithm employs standard image processing methods, such as mathematical morphology and connected component analysis. We have evaluated the developed cell counting system with fourteen digital images of Tobacco Hornworm's nervous system collected for this study with ground-truth cell counts by biology experts. Experimental results show that our system has a minimum error of 1.41% and mean error of 16.68% which is at least forty-four percent better than the algorithm without FRST.

  2. What is cerebral small vessel disease?

    International Nuclear Information System (INIS)

    Onodera, Osamu

    2011-01-01

    An accumulating amount of evidence suggests that the white matter hyperintensities on T 2 weighted brain magnetic resonance imaging predict an increased risk of dementia and gait disturbance. This state has been proposed as cerebral small vessel disease, including leukoaraiosis, Binswanger's disease, lacunar stroke and cerebral microbleeds. However, the concept of cerebral small vessel disease is still obscure. To understand the cerebral small vessel disease, the precise structure and function of cerebral small vessels must be clarified. Cerebral small vessels include several different arteries which have different anatomical structures and functions. Important functions of the cerebral small vessels are blood-brain barrier and perivasucular drainage of interstitial fluid from the brain parenchyma. Cerebral capillaries and glial endfeet, take an important role for these functions. However, the previous pathological investigations on cerebral small vessels have focused on larger arteries than capillaries. Therefore little is known about the pathology of capillaries in small vessel disease. The recent discoveries of genes which cause the cerebral small vessel disease indicate that the cerebral small vessel diseases are caused by a distinct molecular mechanism. One of the pathological findings in hereditary cerebral small vessel disease is the loss of smooth muscle cells, which is an also well-recognized finding in sporadic cerebral small vessel disease. Since pericytes have similar character with the smooth muscle cells, the pericytes should be investigated in these disorders. In addition, the loss of smooth muscle cells may result in dysfunction of drainage of interstitial fluid from capillaries. The precise correlation between the loss of smooth muscle cells and white matter disease is still unknown. However, the function that is specific to cerebral small vessel may be associated with the pathogenesis of cerebral small vessel disease. (author)

  3. 46 CFR 4.03-40 - Public vessels.

    Science.gov (United States)

    2010-10-01

    ... INVESTIGATIONS Definitions § 4.03-40 Public vessels. Public vessel means a vessel that— (a) Is owned, or demise... Department (except a vessel operated by the Coast Guard or Saint Lawrence Seaway Development Corporation...

  4. Welding distortion control in double walled KSTAR vacuum vessel fabrication

    International Nuclear Information System (INIS)

    Oh, D. W.; Lee, G. T.; Kim, H. K.; Yang, H. L.; Bak, J. S.

    2004-01-01

    The KSTAR(Korea Superconducting Tokamak Advanced Research) vacuum vessel is designed to be a double walled structure made of 12mm thick 316LN stainless steel with a D shaped cross-section about 4 m height. Vacuum vessel was pre-fabricated in two parts, 180 degree and 157.5 degree sectors in toroidal direction to meet the transportation purpose. These two parts have to be welded on site with ±2mm allowable fabrication tolerances. 1/3 scaled mock-up model was used to estimate the welding distortion and to ensure the weld quality of vacuum vessel. Gas Tungsten Arc Welding(GTAW), which has been approved by procedure qualification test, was used during mock-up test and vacuum vessel site fabrication. Welding distortion could be managed by allowing for distortion in opposite direction, by applying high restraint using lots of strong backs, by controlling the welding heat input with symmetrical welding sequence. The integrity of the site welding joint was assured by radiographic test, ultrasonic test and leak test with helium detecting method

  5. Blood vessel damage correlated with irradiance for in vivo vascular targeted photodynamic therapy

    Science.gov (United States)

    Zhang, Jinde; Tan, Zou; Niu, Xiangyu; Lin, Linsheng; Lin, Huiyun; Li, Buhong

    2016-10-01

    Vascular targeted photodynamic therapy (V-PDT) has been widely utilized for the prevention or treatment of vascular-related diseases, including age-related macular degeneration, port-wine stains and prostate cancer. In order to quantitative assessment the blood vessel damage during V-PDT, nude mice were implanted with Titanium dorsal skin window chambers for in vivo V-PDT studies. For treatments, various irradiances including 50, 75, 100 and 200 mW/cm2 provided by a 532 nm semiconductor laser were performed with the same total light dose of 30 J/cm2 after the mice were intravenously injection of Rose Bengal for 25 mg/Kg body weight. Laser speckle imaging and microscope were used to monitor blood flow dynamics and vessel constriction during and after V-PDT, respectively. The V-PDT induced vessel damages between different groups were compared. The results show that significant difference in blood vessel damage was found between the lower irradiances (50, 75 and 100 mW/cm2) and higher irradiance (200 mW/cm2), and the blood vessel damage induced by V-PDT is positively correlated with irradiance. This study implies that the optimization of irradiance is required for enhancing V-PDT therapeutic efficiency.

  6. Progress of ITER vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ioki, K., E-mail: Kimihiro.Ioki@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Bayon, A. [F4E, c/ Josep Pla, No. 2, Torres Diagonal Litoral, Edificio B3, E-08019 Barcelona (Spain); Choi, C.H.; Daly, E.; Dani, S.; Davis, J.; Giraud, B.; Gribov, Y.; Hamlyn-Harris, C.; Jun, C.; Levesy, B. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Kim, B.C. [NFRI, 52 Yeoeundong Yuseonggu, Daejeon 305-333 (Korea, Republic of); Kuzmin, E. [NTC “Sintez”, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Le Barbier, R.; Martinez, J.-M. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Pathak, H. [ITER-India, A-29, GIDC Electronic Estate, Sector 25, Gandhinagar 382025 (India); Preble, J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Sa, J.W. [NFRI, 52 Yeoeundong Yuseonggu, Daejeon 305-333 (Korea, Republic of); Terasawa, A.; Utin, Yu. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); and others

    2013-10-15

    Highlights: ► This covers the overall status and progress of the ITER vacuum vessel activities. ► It includes design, R and D, manufacturing and approval process of the regulators. ► The baseline design was completed and now manufacturing designs are on-going. ► R and D includes ISI, dynamic test of keys and lip-seal welding/cutting technology. ► The VV suppliers produced full-scale mock-ups and started VV manufacturing. -- Abstract: Design modifications were implemented in the vacuum vessel (VV) baseline design in 2011–2012 for finalization. The modifications are mostly due to interface components, such as support rails and feedthroughs for the in-vessel coils (IVC). Manufacturing designs are being developed at the domestic agencies (DAs) based on the baseline design. The VV support design was also finalized and tests on scale mock-ups are under preparation. Design of the in-wall shielding (IWS) has progressed, considering the assembly methods and the required tolerances. Further modifications are required to be consistent with the DAs’ manufacturing designs. Dynamic tests on the inter-modular and stub keys to support the blanket modules are being performed to measure the dynamic amplification factor (DAF). An in-service inspection (ISI) plan has been developed and R and D was launched for ISI. Conceptual design of the VV instrumentation has been developed. The VV baseline design was approved by the agreed notified body (ANB) in accordance with the French Nuclear Pressure Equipment Order procedure.

  7. Progress of ITER vacuum vessel

    International Nuclear Information System (INIS)

    Ioki, K.; Bayon, A.; Choi, C.H.; Daly, E.; Dani, S.; Davis, J.; Giraud, B.; Gribov, Y.; Hamlyn-Harris, C.; Jun, C.; Levesy, B.; Kim, B.C.; Kuzmin, E.; Le Barbier, R.; Martinez, J.-M.; Pathak, H.; Preble, J.; Sa, J.W.; Terasawa, A.; Utin, Yu.

    2013-01-01

    Highlights: ► This covers the overall status and progress of the ITER vacuum vessel activities. ► It includes design, R and D, manufacturing and approval process of the regulators. ► The baseline design was completed and now manufacturing designs are on-going. ► R and D includes ISI, dynamic test of keys and lip-seal welding/cutting technology. ► The VV suppliers produced full-scale mock-ups and started VV manufacturing. -- Abstract: Design modifications were implemented in the vacuum vessel (VV) baseline design in 2011–2012 for finalization. The modifications are mostly due to interface components, such as support rails and feedthroughs for the in-vessel coils (IVC). Manufacturing designs are being developed at the domestic agencies (DAs) based on the baseline design. The VV support design was also finalized and tests on scale mock-ups are under preparation. Design of the in-wall shielding (IWS) has progressed, considering the assembly methods and the required tolerances. Further modifications are required to be consistent with the DAs’ manufacturing designs. Dynamic tests on the inter-modular and stub keys to support the blanket modules are being performed to measure the dynamic amplification factor (DAF). An in-service inspection (ISI) plan has been developed and R and D was launched for ISI. Conceptual design of the VV instrumentation has been developed. The VV baseline design was approved by the agreed notified body (ANB) in accordance with the French Nuclear Pressure Equipment Order procedure

  8. Blood culture gram stain, acridine orange stain and direct sensitivity-based antimicrobial therapy of bloodstream infection in patients with trauma.

    Science.gov (United States)

    Behera, B; Mathur, P; Gupta, B

    2010-01-01

    The purpose of this study was to ascertain if the simple practice of Gram stain, acridine orange stain and direct sensitivity determination of positive blood culture bottles could be used to guide early and appropriate treatment in trauma patients with clinical suspicion of sepsis. The study also aimed to evaluate the error in interpreting antimicrobial sensitivity by direct method when compared to standard method and find out if specific antibiotic-organism combination had more discrepancies. Findings from consecutive episodes of blood stream infection at an Apex Trauma centre over a 12-month period are summarized. A total of 509 consecutive positive blood cultures were subjected to Gram staining. AO staining was done in BacT/ALERT-positive Gram-stain negative blood cultures. Direct sensitivity was performed from 369 blood culture broths, showing single type of growth in Gram and acridine orange staining. Results of direct sensitivity were compared to conventional sensitivity for errors. No 'very major' discrepancy was found in this study. About 5.2 and 1.8% minor error rates were noted in gram-positive and gram-negative bacteria, respectively, while comparing the two methods. Most of the discrepancies in gram-negative bacteria were noted in beta lactam - beta lactamase inhibitor combinations. Direct sensitivity testing was not reliable for reporting of methicillin and vancomycin resistance in Staphylococci. Gram stain result together with direct sensitivity testing is required for optimizing initial antimicrobial therapy in trauma patients with clinical suspicion of sepsis. Gram staining and AO staining proved particularly helpful in the early detection of candidaemia.

  9. Is the gram stain useful in the microbiologic diagnosis of VAP? A meta-analysis.

    Science.gov (United States)

    O'Horo, John C; Thompson, Deb; Safdar, Nasia

    2012-08-01

    In a meta-analysis examining respiratory specimen Gram stain for diagnosis of ventilator-associated pneumonia, absence of bacteria on Gram stain had a high negative predictive value, but a positive Gram stain correlated poorly with organisms recovered in culture. Rapid and accurate diagnosis of ventilator-associated pneumonia (VAP) is a major challenge and no generally accepted gold standard exists for VAP diagnosis. We conducted a meta-analysis to examine the role of respiratory specimen Gram stain to diagnose VAP, and the correlation with final culture results. In 21 studies, pooled sensitivity of Gram stain for VAP was 0.79 (95% confidence interval [CI], .77-0.81; P Gram stain for a VAP prevalence of 20%-30% was 91%, suggesting that VAP is unlikely with a negative Gram stain but the positive predictive value of Gram stain was only 40%. Pooled kappa was 0.42 for gram-positive organisms and 0.34 for gram-negative organisms, suggesting fair concordance between organisms on Gram stain and recovery by culture. Therefore, a positive Gram stain should not be used to narrow anti-infective therapy until culture results become available.

  10. Discrimination of p53 immunohistochemistry-positive tumors by its staining pattern in gastric cancer

    International Nuclear Information System (INIS)

    Ando, Koji; Oki, Eiji; Saeki, Hiroshi; Yan, Zhao; Tsuda, Yasuo; Hidaka, Gen; Kasagi, Yuta; Otsu, Hajime; Kawano, Hiroyuki; Kitao, Hiroyuki; Morita, Masaru; Maehara, Yoshihiko

    2015-01-01

    Immunohistochemistry staining of p53 is a cheap and simple method to detect aberrant function of p53. However, there are some discrepancies between the result of immunohistochemistry staining and mutation analysis. This study attempted to find a new definition of p53 staining by its staining pattern. Immunohistochemistry staining of p53 and TP53 gene mutation analysis were performed in 148 gastric cancer patients. Also SNP-CGH array analysis was conducted to four cases. Positive staining of p53 was observed in 88 (59.5%) tumors. Tumors with positive p53 staining showed malignant features compared to negative tumors. Mutation of TP53 gene was observed in 29 (19.6%) tumors with higher age and differentiated type. In positive p53 tumors, two types could be distinguished; aberrant type and scattered type. With comparison to TP53 gene mutation analysis, all the scattered type had wild-type TP53 gene (P = 0.0003). SNP-CGH array showed that scattered-type tumors had no change in the structure of chromosome 17. P53-scattered-type staining tumors may reflect a functionally active nonmutated TP53 gene. In interpretation of p53 immunohistochemistry staining, distinguishing p53-positive tumors by their staining pattern may be important in gastric cancer

  11. A robust, efficient and flexible method for staining myelinated axons in blocks of brain tissue.

    Science.gov (United States)

    Wahlsten, Douglas; Colbourne, Frederick; Pleus, Richard

    2003-03-15

    Previous studies have demonstrated the utility of the gold chloride method for en bloc staining of a bisected brain in mice and rats. The present study explores several variations in the method, assesses its reliability, and extends the limits of its application. We conclude that the method is very efficient, highly robust, sufficiently accurate for most purposes, and adaptable to many morphometric measures. We obtained acceptable staining of commissures in every brain, despite a wide variety of fixation methods. One-half could be stained 24 h after the brain was extracted and the other half could be stained months later. When staining failed because of an exhausted solution, the brain could be stained successfully in fresh solution. Relatively small changes were found in the sizes of commissures several weeks after initial fixation or staining. A half brain stained to reveal the mid-sagittal section could then be sectioned coronally and stained again in either gold chloride for myelin or cresyl violet for Nissl substance. Uncertainty, arising from pixelation of digitized images was far less than errors arising from human judgments about the histological limits of major commissures. Useful data for morphometric analysis were obtained by scanning the surface of a gold chloride stained block of brain with an inexpensive flatbed scanner.

  12. Identification of immune cell infiltration in hematoxylin-eosin stained breast cancer samples: texture-based classification of tissue morphologies

    Science.gov (United States)

    Turkki, Riku; Linder, Nina; Kovanen, Panu E.; Pellinen, Teijo; Lundin, Johan

    2016-03-01

    The characteristics of immune cells in the tumor microenvironment of breast cancer capture clinically important information. Despite the heterogeneity of tumor-infiltrating immune cells, it has been shown that the degree of infiltration assessed by visual evaluation of hematoxylin-eosin (H and E) stained samples has prognostic and possibly predictive value. However, quantification of the infiltration in H and E-stained tissue samples is currently dependent on visual scoring by an expert. Computer vision enables automated characterization of the components of the tumor microenvironment, and texture-based methods have successfully been used to discriminate between different tissue morphologies and cell phenotypes. In this study, we evaluate whether local binary pattern texture features with superpixel segmentation and classification with support vector machine can be utilized to identify immune cell infiltration in H and E-stained breast cancer samples. Guided with the pan-leukocyte CD45 marker, we annotated training and test sets from 20 primary breast cancer samples. In the training set of arbitrary sized image regions (n=1,116) a 3-fold cross-validation resulted in 98% accuracy and an area under the receiver-operating characteristic curve (AUC) of 0.98 to discriminate between immune cell -rich and - poor areas. In the test set (n=204), we achieved an accuracy of 96% and AUC of 0.99 to label cropped tissue regions correctly into immune cell -rich and -poor categories. The obtained results demonstrate strong discrimination between immune cell -rich and -poor tissue morphologies. The proposed method can provide a quantitative measurement of the degree of immune cell infiltration and applied to digitally scanned H and E-stained breast cancer samples for diagnostic purposes.

  13. Neuronal density, size and shape in the human anterior cingulate cortex: a comparison of Nissl and NeuN staining.

    Science.gov (United States)

    Gittins, Rebecca; Harrison, Paul J

    2004-03-15

    There are an increasing number of quantitative morphometric studies of the human cerebral cortex, especially as part of comparative investigations of major psychiatric disorders. In this context, the present study had two aims. First, to provide quantitative data regarding key neuronal morphometric parameters in the anterior cingulate cortex. Second, to compare the results of conventional Nissl staining with those observed after immunostaining with NeuN, an antibody becoming widely used as a selective neuronal marker. We stained adjacent sections of area 24b from 16 adult brains with cresyl violet or NeuN. We measured the density of pyramidal and non-pyramidal neurons, and the size and shape of pyramidal neurons, in laminae II, III, Va, Vb and VI, using two-dimensional counting methods. Strong correlations between the two modes of staining were seen for all variables. However, NeuN gave slightly higher estimates of neuronal density and size, and a more circular perikaryal shape. Brain pH was correlated with neuronal size, measured with both methods, and with neuronal shape. Age and post-mortem interval showed no correlations with any parameter. These data confirm the value of NeuN as a tool for quantitative neuronal morphometric studies in routinely processed human brain tissue. Absolute values are highly correlated between NeuN and cresyl violet stains, but cannot be interchanged. NeuN may be particularly useful when it is important to distinguish small neurons from glia, such as in cytoarchitectural studies of the cerebral cortex in depression and schizophrenia.

  14. Immunohistochemical staining of precursor forms of prostate-specific antigen (proPSA) in metastatic prostate cancer.

    Science.gov (United States)

    Parwani, Anil V; Marlow, Cameron; Demarzo, Angelo M; Mikolajczyk, Stephen D; Rittenhouse, Harry G; Veltri, Robert W; Chan, Theresa Y

    2006-10-01

    Precursors of prostate-specific antigen (proPSA) have been previously shown to be more concentrated in prostate cancer tissue. This study characterizes the immunohistochemical staining (IHS) of proPSA forms in metastatic prostate cancer compared with prostate specific antigen (PSA) and prostatic acid phosphatase (PAP). A tissue microarray, consisting of 74 cases of metastatic prostate carcinoma and control tissues, was used. IHS, using monoclonal antibodies against proPSA with a truncated proleader peptide containing 2 amino acids ([-2]pPSA), native ([-5/-7]pPSA), PSA, and PAP, was analyzed. The monoclonal antibodies were specific for both benign and malignant prostatic glandular tissue. IHS with [-5/-7]pPSA showed the least number of cases with negative staining (3%), and the most number of cases with moderate or strong staining (76%). In the 60 cases where all 4 stains could be evaluated, none of them were negative for proPSA and positive for PSA or PAP, and all 7 cases that were negative for both PSA and PAP showed IHS to proPSA. [-5/-7]pPSA (native proPSA) may be a better marker than PSA and PAP in characterizing metastatic prostate adenocarcinoma, with most of the cases showing positivity for the marker. Even cases that were negative for PSA and PAP, were reactive for proPSA. Such enhanced detection is particularly important in poorly differentiated carcinomas involving metastatic sites where prostate carcinoma is a consideration. A panel of markers, including proPSA, should be performed when metastatic prostate carcinoma is in the differential diagnosis.

  15. Identification criteria of the rare multi-flagellate Lophomonas blattarum: comparison of different staining techniques.

    Science.gov (United States)

    Alam-Eldin, Yosra Hussein; Abdulaziz, Amany Mamdouh

    2015-09-01

    Bronchopulmonary lophomoniasis (BPL) is an emerging disease of potential importance. BPL is presented by non-specific clinical picture and is usually accompanied by immunosuppression. Culture of Lophomonas blattarum is difficult and its molecular diagnosis has not yet been developed. Therefore, microscopic examination of respiratory samples, e.g., bronchoalveolar lavage (BAL) or sputum, is the mainstay of BPL diagnosis. Creola bodies and ciliocytophthoria are two forms of bronchial cells which occur in chest diseases with non-specific clinical picture like that of BPL. Both forms could be misrecognized as multi-flagellates because of their motile cilia in the wet mounts and due to shape variability of L. blattarum in stained smears. The aim of the study is to compare different staining techniques for visualizing L. blattarum to improve the recognition and diagnosis of BPL, to distinguish respiratory epithelial cells from L. blattarum and to decide which stain is recommended in suspected cases of BPL. BAL samples from patients which contain L. blattarum, creola bodies, and ciliocytophthoria were collected then wet mounts were examined. The BAL samples were also stained by Papanicolaou (PAP), Giemsa, hematoxylin and eosin (H & E), trichrome, Gram, and Diff-Quik (DQ) stains. The different staining techniques were compared regarding the stain quality. In wet mounts, the ciliary movement was coordinate and synchronous while the flagellar movement was wavy and leaded to active swimming of L. blattarum. In stained slides, bronchial cells were characterized by the presence of basal nucleus and the terminal bar from which the cilia arise. Trichrome was the best stain in demonstration of cellular details of L. blattarum. H & E, PAP, and Giemsa stains showed good quality of stains. Gram and DQ stains showed only pale hues of L. blattarum. We recommended adding Wheatley's trichrome staining to the differential diagnosis workup of cases of non-specific chest infections

  16. Tumor Budding Detection by Immunohistochemical Staining is Not Superior to Hematoxylin and Eosin Staining for Predicting Lymph Node Metastasis in pT1 Colorectal Cancer.

    Science.gov (United States)

    Okamura, Takuma; Shimada, Yoshifumi; Nogami, Hitoshi; Kameyama, Hitoshi; Kobayashi, Takashi; Kosugi, Shin-ichi; Wakai, Toshifumi; Ajioka, Yoichi

    2016-05-01

    Tumor budding is recognized as an important risk factor for lymph node metastasis in pT1 colorectal cancer. Immunohistochemical staining for cytokeratin has the potential to improve the objective diagnosis of tumor budding over detection based on hematoxylin and eosin staining. However, it remains unclear whether tumor budding detected by immunohistochemical staining is a significant predictor of lymph node metastasis in pT1 colorectal cancer. The purpose of this study was to clarify the clinical significance of tumor budding detected by immunohistochemical staining in comparison with that detected by hematoxylin and eosin staining. This was a retrospective study. The study was conducted at Niigata University Medical & Dental Hospital. We enrolled 265 patients with pT1 colorectal cancer who underwent surgery with lymph node dissection. Tumor budding was evaluated by both hematoxylin and eosin and immunohistochemical staining with the use of CAM5.2 antibody. Receiver operating characteristic curve analyses were conducted to determine the optimal cutoff values for tumor budding detected by hematoxylin and eosin and CAM5.2 staining. Univariate and multivariate analyses were performed to identify the significant factors for predicting lymph node metastasis. Receiver operating characteristic curve analyses revealed that the cutoff values for tumor budding detected by hematoxylin and eosin and CAM5.2 staining for predicting lymph node metastases were 5 and 8. On multivariate analysis, histopathological differentiation (OR, 6.21; 95% CI, 1.16-33.33; p = 0.03) and tumor budding detected by hematoxylin and eosin staining (OR, 4.91; 95% CI, 1.64-14.66; p = 0.004) were significant predictors for lymph node metastasis; however, tumor budding detected by CAM5.2 staining was not a significant predictor. This study was limited by potential selection bias because surgically resected specimens were collected instead of endoscopically resected specimens. Tumor budding detected by

  17. AUTHENTIC MATERIALS IN EXTENSIVE READING CLASS AT STAIN PONOROGO

    Directory of Open Access Journals (Sweden)

    Dhinuk Puspita Kirana

    2013-12-01

    Full Text Available It is widely believed that English Foreign Language (EFL learners need to develop their language proficiency by getting so much input. Moreover, students need to be familiarized with the real English us­age where real forms of communication and cultural knowledge are crucially exposed. Teaching through authentic materials will make the learners feel that they are learning a real language which is used by the real native speakers for real communication. incorporating au­thentic materials helps students acquire an effective communicative competence in the language focus. The research intended to describe the implementation of authentic materials in extensive reading class, the problems arise and the students’ responses toward the authen­tic materials in extensive reading class. The design of the research was Descriptive Qualitative method and the research subject was the lecturer of Extensive Reading class and 33 students in B class of the fourth semester of STAIN Ponorogo who took Extensive Read­ing subject. The instruments used were in the form of observation sheet, interview guideline and questionnaire. The implementation of authentic materials in extensive reading class covered some procedures into three main phases namely (1 Pre­ Activity, (2 Main­ Activity and (3 Post­Activity. The activities in main activity are as follows: (a Pre­ Activity; (b Whilst ­Activity; and (3 The language focus stage. There were problems arose during the implementation in terms of complicated planning, more time allocation and some disinterested students. Finally, the students showed significantly positive attitude toward the implementation of authentic materials in extensive reading class.

  18. Staining Method for Protein Analysis by Capillary Gel Electrophoresis

    Science.gov (United States)

    Wu, Shuqing; Lu, Joann J; Wang, Shili; Peck, Kristy L.; Li, Guigen; Liu, Shaorong

    2009-01-01

    A novel staining method and the associated fluorescent dye were developed for protein analysis by capillary SDS-PAGE. The method strategy is to synthesize a pseudo-SDS dye and use it to replace some of the SDS in SDS–protein complexes so that the protein can be fluorescently detected. The pseudo-SDS dye consists of a long, straight alkyl chain connected to a negative charged fluorescent head and binds to proteins just as SDS. The number of dye molecules incorporated with a protein depends on the dye concentration relative to SDS in the sample solution, since SDS and dye bind to proteins competitively. In this work, we synthesized a series of pseudo-SDS dyes, and tested their performances for capillary SDS-PAGE. FT-16 (a fluorescein molecule linked with a hexadodecyl group) seemed to be the best among all the dyes tested. Although the numbers of dye molecules bound to proteins (and the fluorescence signals from these protein complexes) were maximized in the absence of SDS, high-quality separations were obtained when co-complexes of SDS–protein–dye were formed. The migration time correlates well with protein size even after some of the SDS in the SDS–protein complexes was replaced by the pseudo-SDS dye. Under optimized experimental conditions and using a laser-induced fluorescence detector, limits of detection of as low as 0.13 ng/mL (bovine serum albumin) and dynamic ranges over 5 orders of magnitude in which fluorescence response is proportional to the square root of analyte concentration were obtained. The method and dye were also tested for separations of real-world samples from E. coli. PMID:17874848

  19. Quantum electrodynamics of strong fields

    International Nuclear Information System (INIS)

    Greiner, W.

    1983-01-01

    Quantum Electrodynamics of Strong Fields provides a broad survey of the theoretical and experimental work accomplished, presenting papers by a group of international researchers who have made significant contributions to this developing area. Exploring the quantum theory of strong fields, the volume focuses on the phase transition to a charged vacuum in strong electric fields. The contributors also discuss such related topics as QED at short distances, precision tests of QED, nonperturbative QCD and confinement, pion condensation, and strong gravitational fields In addition, the volume features a historical paper on the roots of quantum field theory in the history of quantum physics by noted researcher Friedrich Hund

  20. Instabilities in strongly coupled plasmas

    CERN Document Server

    Kalman, G J

    2003-01-01

    The conventional Vlasov treatment of beam-plasma instabilities is inappropriate when the plasma is strongly coupled. In the strongly coupled liquid state, the strong correlations between the dust grains fundamentally affect the conditions for instability. In the crystalline state, the inherent anisotropy couples the longitudinal and transverse polarizations, and results in unstable excitations in both polarizations. We summarize analyses of resonant and non-resonant, as well as resistive instabilities. We consider both ion-dust streaming and dust beam-plasma instabilities. Strong coupling, in general, leads to an enhancement of the growth rates. In the crystalline phase, a resonant transverse instability can be excited.

  1. Utility of Acridine Orange staining for detection of bacteria from positive blood cultures.

    Science.gov (United States)

    Neeraja, M; Lakshmi, V; Padmasri, C; Padmaja, K

    2017-08-01

    The diagnostic performance of AO stain was evaluated for the detection of bacteria and or fungi from positive blood cultures. The sensitivity of Gram stain (GS) was 98.26% while Acridine Orange (AO) stain proved to be more sensitive (100%) with a Positive and Negative Predictive Value of 100% each. The specificity of both the stains was 100%. Overall agreement between the two stains was 98.23% (688/700). The organisms that were missed by GS and positive by AO were Candida species (Sutton, 2006) and Gram negative bacilli (GNB) (Sutton, 2006). Sensitivity of GS was 82.35% and AO was 100% among mixed cultures. Immediate reporting of the results of AO stain would have a significant impact on clinical management of patients with serious blood stream infections. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Hydrogen storage in insulated pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.M.; Garcia-Villazana, O. [Lawrence Livermore National Lab., CA (United States)

    1998-08-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current analysis and experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

  3. Neutron Assay System for Confinement Vessel Disposition

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Valdez, Jose I.; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the CVs. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of special nuclear material (SNM) in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le)100-g 239 Pu equivalent in a vessel for safeguards termination. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements.

  4. Automatic Vessel Segmentation on Retinal Images

    Institute of Scientific and Technical Information of China (English)

    Chun-Yuan Yu; Chia-Jen Chang; Yen-Ju Yao; Shyr-Shen Yu

    2014-01-01

    Several features of retinal vessels can be used to monitor the progression of diseases. Changes in vascular structures, for example, vessel caliber, branching angle, and tortuosity, are portents of many diseases such as diabetic retinopathy and arterial hyper-tension. This paper proposes an automatic retinal vessel segmentation method based on morphological closing and multi-scale line detection. First, an illumination correction is performed on the green band retinal image. Next, the morphological closing and subtraction processing are applied to obtain the crude retinal vessel image. Then, the multi-scale line detection is used to fine the vessel image. Finally, the binary vasculature is extracted by the Otsu algorithm. In this paper, for improving the drawbacks of multi-scale line detection, only the line detectors at 4 scales are used. The experimental results show that the accuracy is 0.939 for DRIVE (digital retinal images for vessel extraction) retinal database, which is much better than other methods.

  5. Electrical discharge machining for vessel sample removal

    International Nuclear Information System (INIS)

    Litka, T.J.

    1993-01-01

    Due to aging-related problems or essential metallurgy information (plant-life extension or decommissioning) of nuclear plants, sample removal from vessels may be required as part of an examination. Vessel or cladding samples with cracks may be removed to determine the cause of cracking. Vessel weld samples may be removed to determine the weld metallurgy. In all cases, an engineering analysis must be done prior to sample removal to determine the vessel's integrity upon sample removal. Electrical discharge machining (EDM) is being used for in-vessel nuclear power plant vessel sampling. Machining operations in reactor coolant system (RCS) components must be accomplished while collecting machining chips that could cause damage if they become part of the flow stream. The debris from EDM is a fine talclike particulate (no chips), which can be collected by flushing and filtration

  6. Juvenile localized scleroderma with port wine stain: Coincidental or possible common pathogenetic association

    Directory of Open Access Journals (Sweden)

    Seval Dogruk Kacar

    2015-01-01

    Full Text Available Port wine stain and juvenile localized scleroderma are two different dermatoses usually encountered in pediatric age group. Up to now, there are reports of morphea patients initially diagnosed and treated as port wine stain. Coexistence of both diseases is not found yet. We herein present a case of juvenile localized scleroderma on the left side of trunk, with congenital port wine stain located on the ipsilateral face at V1-V2 distribution.

  7. Juvenile localized scleroderma with port wine stain: coincidental or possible common pathogenetic association.

    Science.gov (United States)

    Kacar, Seval Dogruk; Ozuguz, Pinar; Polat, Serap; Kacar, Emre; Polat, Onur; Tokyol, Cigdem

    2015-01-01

    Port wine stain and juvenile localized scleroderma are two different dermatoses usually encountered in pediatric age group. Up to now, there are reports of morphea patients initially diagnosed and treated as port wine stain. Coexistence of both diseases is not found yet. We herein present a case of juvenile localized scleroderma on the left side of trunk, with congenital port wine stain located on the ipsilateral face at V1-V2 distribution.

  8. A novel vascular-targeting peptide for gastric cancer delivers low-dose TNFα to normalize the blood vessels and improve the anti-cancer efficiency of 5-fluorouracil.

    Science.gov (United States)

    Lu, Lan; Li, Zhi Jie; Li, Long Fei; Shen, Jing; Zhang, Lin; Li, Ming Xing; Xiao, Zhan Gang; Wang, Jian Hao; Cho, Chi Hin

    2017-11-01

    Various vascular-targeted agents fused with tumor necrosis factor α (TNFα) have been shown to improve drug absorption into tumor tissues and enhance tumor vascular function. TCP-1 is a peptide selected through in vivo phage library biopanning against a mouse orthotopic colorectal cancer model and is a promising agent for drug delivery. This study further investigated the targeting ability of TCP-1 phage and peptide to blood vessels in an orthotopic gastric cancer model in mice and assessed the synergistic anti-cancer effect of 5-fluorouracil (5-FU) with subnanogram TNFα targeted delivered by TCP-1 peptide. In vivo phage targeting assay and in vivo colocalization analysis were carried out to test the targeting ability of TCP-1 phage/peptide. A targeted therapy for improvement of the therapeutic efficacy of 5-FU and vascular function was performed through administration of TCP-1/TNFα fusion protein in this model. TCP-1 phage exhibited strong homing ability to the orthotopic gastric cancer after phage injection. Immunohistochemical staining suggested that and TCP-1 phage/TCP-1 peptide could colocalize with tumor vascular endothelial cells. TCP-1/TNFα combined with 5-FU was found to synergistically inhibit tumor growth, induce apoptosis and reduce cell proliferation without evident toxicity. Simultaneously, subnanogram TCP-1/TNFα treatment normalized tumor blood vessels. Targeted delivery of low-dose TNFα by TCP-1 peptide can potentially modulate the vascular function of gastric cancer and increase the drug delivery of chemotherapeutic drugs. Copyright © 2017. Published by Elsevier Inc.

  9. Short proofs of strong normalization

    OpenAIRE

    Wojdyga, Aleksander

    2008-01-01

    This paper presents simple, syntactic strong normalization proofs for the simply-typed lambda-calculus and the polymorphic lambda-calculus (system F) with the full set of logical connectives, and all the permutative reductions. The normalization proofs use translations of terms and types to systems, for which strong normalization property is known.

  10. Exponential Stabilization of an Underactuated Surface Vessel

    Directory of Open Access Journals (Sweden)

    Kristin Y. Pettersen

    1997-07-01

    Full Text Available The paper shows that a large class of underactuated vehicles cannot be asymptotically stabilized by either continuous or discontinuous state feedback. Furthermore, stabilization of an underactuated surface vessel is considered. Controllability properties of the surface vessels is presented, and a continuous periodic time-varying feedback law is proposed. It is shown that this feedback law exponentially stabilizes the surface vessel to the origin, and this is illustrated by simulations.

  11. Computerized reactor pressure vessel materials information system

    International Nuclear Information System (INIS)

    Strosnider, J.; Monserrate, C.; Kenworthy, L.D.; Tether, C.D.

    1980-10-01

    A computerized information system for storage and retrieval of reactor pressure vessel materials data was established, as part of Task Action Plan A-11, Reactor Vessel Materials Toughness. Data stored in the system are necessary for evaluating the resistance of reactor pressure vessels to flaw-induced fracture. This report includes (1) a description of the information system; (2) guidance on accessing the system; and (3) a user's manual for the system

  12. Strong-back safety latch

    International Nuclear Information System (INIS)

    DeSantis, G.N.

    1995-01-01

    The calculation decides the integrity of the safety latch that will hold the strong-back to the pump during lifting. The safety latch will be welded to the strong-back and will latch to a 1.5-in. dia cantilever rod welded to the pump baseplate. The static and dynamic analysis shows that the safety latch will hold the strong-back to the pump if the friction clamps fail and the pump become free from the strong-back. Thus, the safety latch will meet the requirements of the Lifting and Rigging Manual for under the hook lifting for static loading; it can withstand shock loads from the strong-back falling 0.25 inch

  13. Microbiology of liver abscesses and the predictive value of abscess gram stain and associated blood cultures.

    Science.gov (United States)

    Chemaly, Roy F; Hall, Gerri S; Keys, Thomas F; Procop, Gary W

    2003-08-01

    Although rare, pyogenic liver abscesses are potentially fatal. We evaluated the predictive value of Gram stain of liver abscess aspirates and temporally associated blood cultures. Gram stains detected bacteria in 79% of the liver abscesses tested. The sensitivity and specificity of Gram stain of the liver abscesses were 90% and 100% for Gram-positive cocci (GPC) and 52% and 94% for Gram-negative bacilli (GNB). The sensitivities of the blood cultures for any GPC and GNB present in the liver abscess were 30% and 39%, respectively. Although, Gram stains and blood cultures offer incomplete detection of the microbial contents of pyogenic liver abscesses, both tests should always accompany liver abscess cultures.

  14. A combined Bodian-Nissl stain for improved network analysis in neuronal cell culture.

    Science.gov (United States)

    Hightower, M; Gross, G W

    1985-11-01

    Bodian and Nissl procedures were combined to stain dissociated mouse spinal cord cells cultured on coverslips. The Bodian technique stains fine neuronal processes in great detail as well as an intracellular fibrillar network concentrated around the nucleus and in proximal neurites. The Nissl stain clearly delimits neuronal cytoplasm in somata and in large dendrites. A combination of these techniques allows the simultaneous depiction of neuronal perikarya and all afferent and efferent processes. Costaining with little background staining by either procedure suggests high specificity for neurons. This procedure could be exploited for routine network analysis of cultured neurons.

  15. How to replace a reactor pressure vessel

    International Nuclear Information System (INIS)

    Huber, R.

    1996-01-01

    A potential life extending procedure for a nuclear reactor after, say, 40 years of service life, might in some circumstances be the replacement of the reactor pressure vessel. Neutron induced degradation of the vessel might make replacement by one of a different material composition desirable, for example. Although the replacement of heavy components, such as steam generators, has been possible for many years, the pressure vessel presents a much more demanding task if only because it is highly irradiated. Some preliminary feasibility studies by Siemens are reported for the two removal strategies that might be considered. These are removal of the entire pressure vessel in one piece and dismantling it into sections. (UK)

  16. Prestressed reactor vessel for nuclear power plants

    International Nuclear Information System (INIS)

    Schoening, J.; Schwiers, H.G.

    1982-01-01

    With usual pressure vessels for nuclear reactor plants, especially for gas-cooled nuclear reactors, the load occurring due to the inner overpressure, especially the tensile load affecting the vessel top and/or bottom, their axis of inertia being horizontal, shall be compensated without a supplementary modification in design of the top and/or the bottom. This is attained by choosing an appropriate prestressing system of the vessel wall in the field the top and/or the bottom, so that the top and/or the bottom form a tension vault directed towards the interior of the vessel. (orig.) [de

  17. Reactor vessel decommissioning project. Final report

    International Nuclear Information System (INIS)

    Schoonen, D.H.

    1984-09-01

    This report describes a reactor vessel decommissioning project; it documents and explains the project objectives, scope, performance results, and sodium removal process. The project was successfully completed in FY-1983, within budget and without significant problems or adverse impact on the environment. Waste generated by the operation included the reactor vessel, drained sodium, and liquid, solid, and gaseous wastes which were significantly less than project estimates. Personnel radiation exposures were minimized, such that the project total was one-half the predicted exposure level. Except for the sodium removed, the material remaining in the reactor vessel is essentially the same as when the vessel arrived for processing

  18. Safety vessels for explosive fusion reactor

    International Nuclear Information System (INIS)

    Mineev, V.

    1994-01-01

    The failure of several types of geometrically similar cylindrical and spherical steel and glass fibers vessels filled with water or air was investigated when an explosive charge of TNT was detonated in the center. Vessels had radius 50-1000 mm, thickness of walls 2-20%. The detonation on TNT imitated energy release. The parameter: K = M/mf is a measure of the strength of the vessel where M is the mass of the vessel, and mf is the mass of TNT for which the vessel fails. This demanded 2-4 destroyed and nondestroyed shots. It may be showed that: K=A/σ f where σ f is the fracture stress of the material vessel, and A = const = F(energy TNT, characteristic of elasticity of vessel material). The chief results are the following: (1) A similar increase in the geometrical dimensions of steel vessels by a factor of 10 leads to the increase of parameter K in about 5 times and to decrease of failure deformation in 7 times (scale effect). (2) For glass fibers, scale effect is absent. (3) This problem is solved in terms of theory energetic scale effect. (4) The concept of TNT equivalent explosive makes it possible to use these investigations to evaluate the response of safety vessels for explosive fusion reactor

  19. Determinants of injuries in passenger vessel accidents.

    Science.gov (United States)

    Yip, Tsz Leung; Jin, Di; Talley, Wayne K

    2015-09-01

    This paper investigates determinants of crew and passenger injuries in passenger vessel accidents. Crew and passenger injury equations are estimated for ferry, ocean cruise, and river cruise vessel accidents, utilizing detailed data of individual vessel accidents that were investigated by the U.S. Coast Guard during the time period 2001-2008. The estimation results provide empirical evidence (for the first time in the literature) that crew injuries are determinants of passenger injuries in passenger vessel accidents. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Increase of cyclic durability of pressure vessels

    International Nuclear Information System (INIS)

    Vorona, V.A.; Zvezdin, Yu.I.

    1980-01-01

    The durability of multilayer pressure vessels under cyclic loading is compared with single-layer vessels. The relative conditional durability is calculated taking into account the assumption on the consequent destruction of layers and viewing a vessel wall as an indefinite plate. It is established that the durability is mainly determined by the number of layers and to a lesser degree depends on the relative size of the defect for the given layer thickness. The advantage of the multilayer vessels is the possibility of selecting layer materials so that to exclude the effect of agressive corrosion media on the strength [ru

  1. Vessel size measurements in angiograms: Manual measurements

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Dmochowski, Jacek; Nazareth, Daryl P.; Miskolczi, Laszlo; Nemes, Balazs; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2003-01-01

    Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical practice, choosing to indicate the edges of vessels and catheters to determine sizes and calibrate magnifications, i.e., manual measurements. Thus, we undertook an investigation of the accuracy and precision of vessel sizes calculated from manually indicated edges of vessels. Manual measurements were performed by three neuroradiologists and three physicists. Vessel sizes ranged from 0.1-3.0 mm in simulation studies and 0.3-6.4 mm in phantom studies. Simulation resolution functions had full-widths-at-half-maximum (FWHM) ranging from 0.0 to 0.5 mm. Phantom studies were performed with 4.5 in., 6 in., 9 in., and 12 in. image intensifier modes, magnification factor = 1, with and without zooming. The accuracy and reproducibility of the measurements ranged from 0.1 to 0.2 mm, depending on vessel size, resolution, and pixel size, and zoom. These results indicate that manual measurements may have accuracies comparable to automated techniques for vessels with sizes greater than 1 mm, but that automated techniques which take into account the resolution function should be used for vessels with sizes smaller than 1 mm

  2. Vessels for elevated temperature service

    International Nuclear Information System (INIS)

    O'Donnell, W.J.; Porowski, J.S.

    1983-01-01

    The subject is covered in chapters, entitled: introduction (background; elevated temperature concerns; design tools); design of pressure vessels for elevated temperature per ASME code; basic elevated temperature failure modes; allowable stresses and strains per ASME code (basic allowable stress limits; ASME code limits for bending; time-fraction summations; strain limits; buckling and instability; negligible creep and stress-rupture effects); combined membrane and bending stresses in creep regime; thermal stress cycles; bounding methods based on elastic core concept (bounds on accumulated strains; more accurate bounds; strain ranges; maximum stresses; strains at discontinuities); elastic follow-up; creep strain concentrations; time-dependent fatigue (combined creep rupture and fatigue damage; limits for inelastic design analyses; limits for elastic design analyses); flaw evaluation techniques; type 316 stainless steel; type 304 stainless steel; steel 2 1/4Cr1Mo; Inconel 718; Incolloy 800; Hastelloy X; detailed inelastic design analyses. (U.K.)

  3. Milestones in pressure vessel technology

    International Nuclear Information System (INIS)

    Spence, J.; Nash, D.H.

    2004-01-01

    The progress of pressure vessel technology over the years has been influenced by many important events. This paper identifies a number of 'milestones' which have provided a stimulus to analysis methods, manufacturing, operational processes and new pressure equipment. The formation of a milestone itself along with its subsequent development is often critically dependent on the work of many individuals. It is postulated that such developments takes place in cycles, namely, an initial idea, followed sometimes by unexpected failures, which in turn stimulate analysis or investigation, and when confidence is established, followed finally by the emergence of codes ad standards. Starting from the industrial revolution, key milestones are traced through to the present day and beyond

  4. Reactor pressure vessel thermal annealing

    International Nuclear Information System (INIS)

    Lee, A.D.

    1997-01-01

    The steel plates and/or forgings and welds in the beltline region of a reactor pressure vessel (RPV) are subject to embrittlement from neutron irradiation. This embrittlement causes the fracture toughness of the beltline materials to be less than the fracture toughness of the unirradiated material. Material properties of RPVs that have been irradiated and embrittled are recoverable through thermal annealing of the vessel. The amount of recovery primarily depends on the level of the irradiation embrittlement, the chemical composition of the steel, and the annealing temperature and time. Since annealing is an option for extending the service lives of RPVs or establishing less restrictive pressure-temperature (P-T) limits; the industry, the Department of Energy (DOE) and the Nuclear Regulatory Commission (NRC) have assisted in efforts to determine the viability of thermal annealing for embrittlement recovery. General guidance for in-service annealing is provided in American Society for Testing and Materials (ASTM) Standard E 509-86. In addition, the American Society of Mechanical Engineers (ASME) Code Case N-557 addresses annealing conditions (temperature and duration), temperature monitoring, evaluation of loadings, and non-destructive examination techniques. The NRC thermal annealing rule (10 CFR 50.66) was approved by the Commission and published in the Federal Register on December 19, 1995. The Regulatory Guide on thermal annealing (RG 1.162) was processed in parallel with the rule package and was published on February 15, 1996. RG 1.162 contains a listing of issues that need to be addressed for thermal annealing of an RPV. The RG also provides alternatives for predicting re-embrittlement trends after the thermal anneal has been completed. This paper gives an overview of methodology and recent technical references that are associated with thermal annealing. Results from the DOE annealing prototype demonstration project, as well as NRC activities related to the

  5. Comparison of algorithms for blood stain detection applied to forensic hyperspectral imagery

    Science.gov (United States)

    Yang, Jie; Messinger, David W.; Mathew, Jobin J.; Dube, Roger R.

    2016-05-01

    Blood stains are among the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Early detection of blood stains is particularly important since the blood reacts physically and chemically with air and materials over time. Accurate identification of blood remnants, including regions that might have been intentionally cleaned, is an important aspect of forensic investigation. Hyperspectral imaging might be a potential method to detect blood stains because it is non-contact and provides substantial spectral information that can be used to identify regions in a scene with trace amounts of blood. The potential complexity of scenes in which such vast violence occurs can be high when the range of scene material types and conditions containing blood stains at a crime scene are considered. Some stains are hard to detect by the unaided eye, especially if a conscious effort to clean the scene has occurred (we refer to these as "latent" blood stains). In this paper we present the initial results of a study of the use of hyperspectral imaging algorithms for blood detection in complex scenes. We describe a hyperspectral imaging system which generates images covering 400 nm - 700 nm visible range with a spectral resolution of 10 nm. Three image sets of 31 wavelength bands were generated using this camera for a simulated indoor crime scene in which blood stains were placed on a T-shirt and walls. To detect blood stains in the scene, Principal Component Analysis (PCA), Subspace Reed Xiaoli Detection (SRXD), and Topological Anomaly Detection (TAD) algorithms were used. Comparison of the three hyperspectral image analysis techniques shows that TAD is most suitable for detecting blood stains and discovering latent blood stains.

  6. [Comparison of four different staining methods for ear cytology of dogs with otitis externa].

    Science.gov (United States)

    Bouassiba, C; Osthold, W; Mueller, R S

    2013-01-01

    Cytological examination is crucial for the diagnosis and classification of canine otitis externa. Staining should reveal micro-organisms as perpetuating factors of otitis externa. The aim of the study was to compare four different staining methods (Diff-Quik®, Diff-Quik® after dipping in acetone, Gram Quick stain® and a commercial rapid stain for otitis externa) for ear cytology of dogs with otitis externa and to investigate the agreement of cytology and culture. In a study evaluating dogs with otitis externa, five ear swabs (one for culture and four for cytology) were taken from the horizontal part of the external auditory canal of 224 affected ears and compared semi-quantitatively. Diff-Quik® with and without prior dipping in acetone as well as the Gram Quick stain® displayed a high degree of agreement in the detection of micro-organisms (cocci p = 0.2366; rods p = 0.4832; yeasts p = 0.1574), while the commercial otitis rapid stain revealed significantly less micro-organisms (p stains corresponded to the culture results by >  70%; the agreement was lower with the commercial otitis rapid stain. The quickest and easiest method was staining with Diff-Quik®. Diff-Quik® with or without prior dipping in acetone and the Gram Quick stain® had a high agreement in the detection of microorganisms and can thus be considered nearly equivalent for the diagnosis of otitis externa infectiosa. The commercial otitis rapid stain is less reliable. Based on this study Diff-Quik® can be recommended for the routine cytology of ear swabs. Additionally, a culture may be indicated and must be interpreted in the context of the cytology.

  7. Mechanisms of superficial micropunctate corneal staining with sodium fluorescein: the contribution of pooling.

    Science.gov (United States)

    Bandamwar, Kalika L; Garrett, Qian; Papas, Eric B

    2012-04-01

    To establish if sodium fluorescein (SFL) dye accumulation within intercellular spaces on the ocular surface contributes to the appearance of superficial punctate corneal staining. Thirteen subjects bilaterally wore PureVision™ lenses that had been pre-soaked in ReNu MultiPlus® multipurpose solution. After 1h of lens wear, corneal staining with SFL was assessed using a standard slit-lamp technique. Participants who presented with bilateral, corneal staining were selected for further evaluation. A randomly selected eye was rinsed with saline three times. Fellow eyes (control) received no rinsing. After each rinse, the appearance of SFL staining was recorded without any further instillation of the dye. To eliminate any confounding effects of staining due to residual fluorescein in the tear menisci, corneal staining was induced in freshly excised, isolated, rabbit eyes by topical administration of 0.001% PHMB and staining, rinsing and grading were performed as above. Nine out of 13 subjects presented with bilateral diffuse corneal staining (mean grade±SD: 2.4±0.7). The mean staining grades in test and control eyes respectively after each of the three rinses were (1) 2.41±0.41, 2.25±0.69 (p=0.9); (2) 2.34±0.79, 2.1±0.83 (p=0.8); and (3) 1.71±0.65, 1.60±0.79 (p=0.6) there was no significant reduction in staining with rinsing (p>0.05) and no difference was observed between test and control eyes at any sampling-point. Similar observations made in ex vivo rabbit eyes replicated these results. Pooling or accumulation of SFL solution within intercellular spaces does not appear to contribute to the appearance of superficial micropunctate corneal staining. Copyright © 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  8. Solutal Marangoni flow as the cause of ring stains from drying salty colloidal drops

    Science.gov (United States)

    Marin, Alvaro; Karpitschka, Stefan; Rossi, Massimiliano; Kaehler, Christian J.; Noguera-Marin, Diego; Rodriguez-Valverde, Miguel A.

    2017-11-01

    Salts can be found in different forms in almost any evaporating droplet in nature, our homes and in laboratories. The transport processes in such apparently simple systems differ strongly from `sweet' evaporating droplets since the liquid flows in the inverse direction due to Marangoni stresses at the surface. Such an effect has crucial consequences to salt crystallization processes and to the evaporation itself. In this work we show measurements that not only confirm clearly the details of the inverted flow patterns, but also permit us to calculate the surface tension gradients responsible for the reversal. Such a reversal does not prevent the coffee-stain effect; on the contrary, particles accumulate and get trapped at the liquid-air interface driven by the surface flow. In order to prove this, we show measurements of the full three-dimensional flow inside the evaporating salty droplet, confocal imaging is used to quantify the growth of the particle deposits for different salt concentrations, and we compare the experimental results with numerical simulations that capture the solvent evaporation, the evaporation-induced liquid flow and the quasi-equilibrium liquid-gas interface.

  9. New bioreactor vessel for tissue engineering of human nasal septal chondrocytes

    Directory of Open Access Journals (Sweden)

    Princz Sascha

    2016-09-01

    Full Text Available Cultivation of human nasal septal chondrocytes in a self-established automated bioreactor system with a new designed reactor glass vessel and the results of a computational fluid dynamics model are presented. The first results show the effect of a homogeneous fluidic condition of the continuous medium flow and the resulting stresses on the scaffolds’ surface and their influence on the migration of the cells into the scaffold matrix under these conditions. For this purpose computational models, generated with the computational fluid dynamics software STAR-CCM+, and the results of alcian blue staining for newly synthesized sulphated glycosaminoglycans have been compared during cultivation in the new and a first version of the glass reactor vessel with inhomogeneous fluidic conditions, with the same automated bioreactor system and under similar cultivation conditions.

  10. A computational algorithm addressing how vessel length might depend on vessel diameter

    Science.gov (United States)

    Jing Cai; Shuoxin Zhang; Melvin T. Tyree

    2010-01-01

    The objective of this method paper was to examine a computational algorithm that may reveal how vessel length might depend on vessel diameter within any given stem or species. The computational method requires the assumption that vessels remain approximately constant in diameter over their entire length. When this method is applied to three species or hybrids in the...

  11. Vessel classification method based on vessel behavior in the port of Rotterdam

    NARCIS (Netherlands)

    Zhou, Y.; Daamen, W.; Vellinga, T.; Hoogendoorn, S.P.

    2015-01-01

    AIS (Automatic Identification System) data have proven to be a valuable source to investigate vessel behavior. The analysis of AIS data provides a possibility to recognize vessel behavior patterns in a waterway area. Furthermore, AIS data can be used to classify vessel behavior into several

  12. Nd:YAG laser combined with gold nanorods for potential application in port-wine stains: an in vivo study.

    Science.gov (United States)

    Xing, Linzhuang; Chen, Bin; Li, Dong; Wu, Wenjuan; Wang, Guoxiang

    2017-11-01

    Neodymium:yttrium aluminum garnet (Nd:YAG) lasers exhibit considerable potential for treating deeply buried port-wine stains. However, the application of Nd:YAG laser is limited by its weak absorption to blood. This in vivo study tested the efficacy and safety of utilizing thiol-terminated methoxypolyethylene glycol-modified gold nanorods (PEG-GNRs) to enhance the absorption of Nd:YAG laser to blood. Mouse mesentery and dorsal skinfold chamber (DSC) model were prepared to analyze the thermal responses of a single venule without anatomic structures, as well as blood vessels in the complex structure of the skin, to laser light. After the injection of 0.44 mg of PEG-GNRs, the required threshold density of laser energy for blood coagulation and complete vasoconstriction decreased from 24 to 18  J/cm2 in the mesentery model and from 36 to 31  J/cm2 in the DSC model. The laser pulse required for blood coagulation and complete vasoconstriction decreased by 67.75% and 62.25% on average in the mesentery model and by 67.55% and 54.45% on average in the DSC model. Histological and histochemical results confirmed that PEG-GNRs are nontoxic in the entire mouse life span. Therefore, combining PEG-GNRs with Nd:YAG laser may be effective and safe for inducing an obvious thermal response of blood vessels under low energy density and minimal pulse conditions. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  13. Nuclear reactor with a suspended vessel

    International Nuclear Information System (INIS)

    Lemercier, Guy.

    1977-01-01

    This invention relates to a nuclear reactor with a suspended vessel and applies in particular when this is a fast reactor, the core or active part of the reactor being inside the vessel and immersed under a suitable volume of flowing liquid metal to cool it by extracting the calories released by the nuclear fission in the fuel assemblies forming this core [fr

  14. Fabrication of Separator Demonstration Facility process vessel

    International Nuclear Information System (INIS)

    Oberst, E.F.

    1985-01-01

    The process vessel system is the central element in the Separator Development Facility (SDF). It houses the two major process components, i.e., the laser-beam folding optics and the separators pods. This major subsystem is the critical-path procurement for the SDF project. Details of the vaious parts of the process vessel are given

  15. Irradiation embrittlement of reactor vessel steels

    International Nuclear Information System (INIS)

    Bros, J.

    2000-01-01

    From the historical decision of closing the Yankee Rowe NPP because of the uncertainties on the level of reactor pressure vessel neutron embrittlement, this paper reviews the technical-scientist bases of the degradation phenomena, and refers to the evolution of reactor pressure vessel radiation surveillance programs. (Author)

  16. Ultrasound periodic inspections of reactor pressure vessels

    International Nuclear Information System (INIS)

    Haniger, L.

    1980-01-01

    Two versions are described of ultrasonic equipment for periodic inspections of reactor pressure vessels. One uses the principle of exchangeable programmators with solid-state logic while the other uses programmable logic with semiconductor memories. The equipment is to be used for inspections of welded joints on the upper part of the V-1 reactor pressure vessel. (L.O.)

  17. Elastic plastic buckling of elliptical vessel heads

    International Nuclear Information System (INIS)

    Alix, M.; Roche, R.L.

    1981-08-01

    The risks of buckling of dished vessel head increase when the vessel is thin walled. This paper gives the last results on experimental tests of 3 elliptical heads and compares all the results with some empirical formula dealing with elastic and plastic buckling

  18. Analyzing Vessel Behavior Using Process Mining

    NARCIS (Netherlands)

    Maggi, F.M.; Mooij, A.J.; Aalst, W.M.P. van der

    2013-01-01

    In the maritime domain, electronic sensors such as AIS receivers and radars collect large amounts of data about the vessels in a certain geographical area. We investigate the use of process mining techniques for analyzing the behavior of the vessels based on these data. In the context of maritime

  19. Oxidized Lipoprotein as a Major Vessel Cell Proliferator in Oxidized Human Serum.

    Directory of Open Access Journals (Sweden)

    Yoshiro Saito

    Full Text Available Oxidative stress is correlated with the incidence of several diseases such as atherosclerosis and cancer, and oxidized biomolecules have been determined as biomarkers of oxidative stress; however, the detailed molecular relationship between generated oxidation products and the promotion of diseases has not been fully elucidated. In the present study, to clarify the role of serum oxidation products in vessel cell proliferation, which is related to the incidence of atherosclerosis and cancer, the major vessel cell proliferator in oxidized human serum was investigated. Oxidized human serum was prepared by free radical exposure, separated using gel chromatography, and then each fraction was added to several kinds of vessel cells including endothelial cells and smooth muscle cells. It was found that a high molecular weight fraction in oxidized human serum specifically induced vessel cell proliferation. Oxidized lipids were contained in this high molecular weight fraction, while cell proliferation activity was not observed in oxidized lipoprotein-deficient serum. Oxidized low-density lipoproteins induced vessel cell proliferation in a concentration-dependent manner. Taken together, these results indicate that oxidized lipoproteins containing lipid oxidation products function as a major vessel cell proliferator in oxidized human serum. These findings strongly indicate the relevance of determination of oxidized lipoproteins and lipid oxidation products in the diagnosis of vessel cell proliferation-related diseases such as atherosclerosis and cancer.

  20. Marine Red Staining of a Pennsylvanian Carbonate Slope: Environmental and Oceanographic Significance

    NARCIS (Netherlands)

    van der Kooij, B.; Immenhauser, A.M.; Steuber, T; Hagmaier, M.; Bahamonde, J.R.; Samankassou, E.; Merino Tomé, O.

    2007-01-01

    Red-stained platform facies are a common feature of many carbonate settings throughout the geological record. Although the mechanisms involved in red staining of subaerially exposed or argillaceous, peri-platforin limestones are reasonably well understood, the environmental and oceanographic

  1. Identification and age estimation of blood stains on colored backgrounds by near infrared spectroscopy

    NARCIS (Netherlands)

    Edelman, Gerda; Manti, Vicky; van Ruth, Saskia M.; van Leeuwen, Ton; Aalders, Maurice

    2012-01-01

    Non-destructive identification and subsequent age estimation of blood stains are significant steps in forensic casework. The latter can provide important information on the temporal aspects of a crime. As previously shown, visible spectroscopy of blood stains on white backgrounds can successfully be

  2. Touch cytology in diagnosing Helicobacter pylori: comparison of four staining methods.

    Science.gov (United States)

    Hashemi, M R; Rahnavardi, M; Bikdeli, B; Dehghani Zahedani, M; Iranmanesh, F

    2008-06-01

    Helicobacter pylori (Hp), a major cause of peptic ulcer disease and an important risk factor for gastric malignancy, can be diagnosed by several methods. Touch cytology (TC) of the gastric mucosa has been noted to give good results and has been found to be very simple, inexpensive and rapid. However, evidence regarding the accuracy of different staining methods of TC is lacking. The present study aims at defining the diagnostic accuracy of four different staining methods of TC. Biopsy specimens were taken from the antral mucosa of one hundred consecutive patients referred for upper gastrointestinal endoscopy (UGIE) for various indications. TC slides were processed by four staining methods: Wright, Giemsa, Papanicolaou and Gram. Rapid urease test (RUT) and histological examination of specimens were also performed. The same experienced pathologist evaluated the coded samples. A patient's Hp status was established by minimum concordance of the three tests, including histology, RUT, and 'Touch mean'. The latter was defined positive when at least three of the four TC staining methods were positive. Forty-six patients (46%) were positive for Hp according to Hp status. TC stained by Wright had excellent agreement with both histology (kappa = 0.80, P stained TC (88.89%) was significantly more specific than both Giemsa- (74.07%; P stained (70.37%; P stained TC can safely substitute for histology. However, when assessment for severity of mucosal damage or cell atypias is meant, histology cannot be neglected.

  3. Red alder kitchen cabinets—How does application of commercial stains influence customer choice?

    Science.gov (United States)

    David Nicholls; Joseph. Roos

    2007-01-01

    A better understanding of consumer reaction and preferences for red alder (Alnus rubra Bong.) secondary products will help Alaska producers in entering new markets. In this study, red alder kitchen cabinets were commercially stained to six different levels and displayed at home shows in Portland, Oregon, and Anchorage, Alaska. The stains simulated...

  4. Complete staining of human spermatozoa and immature germ cells combined with phase contrast microscopy

    DEFF Research Database (Denmark)

    Michael, A Y; Drejer, J O; Bagger, P V

    1987-01-01

    A method combining Janus green B and Thymol blue stains the anterior part of the head, the nuclear membrane, middle piece, and tail of spermatozoa light green and the nucleus deep purple. The method provides excellent stained preparations for the evaluation of sperm morphology by phase contrast...

  5. Supravital dithizone staining in the isolation of human and rat pancreatic islets

    DEFF Research Database (Denmark)

    Hansen, W A; Christie, M R; Kahn, R

    1989-01-01

    Dithizone, a zinc chelating agent, is known to selectively stain the islets of Langerhans in the pancreas. In the present study, we have used this stain to aid the identification of islets in material obtained by collagenase digestion of human pancreas. Islets were shown to rapidly and reversibly...... techniques for the large scale isolation of functionally intact human islets....

  6. Combined histochemical staining, RNA amplification, regional, and single cell cDNA analysis within the hippocampus.

    Science.gov (United States)

    Ginsberg, Stephen D; Che, Shaoli

    2004-08-01

    The use of five histochemical stains (cresyl violet, thionin, hematoxylin & eosin, silver stain, and acridine orange) was evaluated in combination with an expression profiling paradigm that included regional and single cell analyses within the hippocampus of post-mortem human brains and adult mice. Adjacent serial sections of human and mouse hippocampus were labeled by histochemistry or neurofilament immunocytochemistry. These tissue sections were used as starting material for regional and single cell microdissection followed by a newly developed RNA amplification procedure (terminal continuation (TC) RNA amplification) and subsequent hybridization to custom-designed cDNA arrays. Results indicated equivalent levels of global hybridization signal intensity and relative expression levels for individual genes for hippocampi stained by cresyl violet, thionin, and hematoxylin & eosin, and neurofilament immunocytochemistry. Moreover, no significant differences existed between the Nissl stains and neurofilament immunocytochemistry for individual CA1 neurons obtained via laser capture microdissection. In contrast, a marked decrement was observed in adjacent hippocampal sections stained for silver stain and acridine orange, both at the level of the regional dissection and at the CA1 neuron population level. Observations made on the cDNA array platform were validated by real-time qPCR using primers directed against beta-actin and glyceraldehyde-3 phosphate dehydrogenase. Thus, this report demonstrated the utility of using specific Nissl stains, but not stains that bind RNA species directly, in both human and mouse brain tissues at the regional and cellular level for state-of-the-art molecular fingerprinting studies.

  7. Glucose transporter distribution in the vessels of the central nervous system of the axolotl Ambystoma mexicanum (Urodela: Ambystomatidae).

    Science.gov (United States)

    Lazzari, Maurizio; Bettini, Simone; Ciani, Franco; Franceschini, Valeria

    2008-10-01

    The GLUT-1 isoform of the glucose transporter is commonly considered a reliable molecular marker of blood-brain barrier endothelia in the neural vasculature organized in a three-dimensional network of single vessels. The central nervous system of the axolotl Ambystoma mexicanum is characterized by a vascular architecture that contains both single and paired vessels. The presence and distribution of the GLUT-1 transporter are studied in this urodele using both immunoperoxidase histochemistry and immunogold technique. Light microscopy reveals immunopositivity in both parenchymal and meningeal vessels. The transverse-sectioned pairs of vessels do not show the same size. Furthermore, in the same pair, the two elements often differ in diameter. The main regions of the central nervous system show a different percentage of the paired structures. Only immunogold cytochemistry reveals different staining intensity in the two adjoined elements of a vascular pair. Colloidal gold particles show an asymmetric distribution in the endothelia of both single and paired vessels. These particles are more numerous on the abluminal surface than on the luminal one. The particle density is calculated in both vascular types. The different values could indicate functional differences between single and paired vessels and between the two adjoined elements of a pair, regarding glucose transport.

  8. Metallurgy of steels for PWR pressure vessels

    International Nuclear Information System (INIS)

    Kepka, M.; Mocek, J.; Barackova, L.

    1980-01-01

    A survey and the chemical compositions are presented of reactor pressure vessel steels. The metallurgy is described of steel making for pressure vessels in Japan and the USSR. Both acidic and alkaline open-hearth steel is used for the manufacture of ingots. The leading world manufacturers of forging ingots for pressure vessels, however, exclusively use electric steel. Vacuum casting techniques are exclusively used. Experience is shown gained with the introduction of the manufacture of forging ingots for pressure vessels at SKODA, Plzen. The metallurgical procedure was tested utilizing alkaline open hearths, electric arc furnaces and facilities for vacuum casting of steel. Pure charge raw materials should be used for securing high steel purity. Prior to forging pressure vessel rings, not only should sufficiently big bottoms and heads be removed but also the ingot middle part should be scrapped showing higher contents of impurities and nonhomogeneous structure. (B.S.)

  9. Metallurgy of steels for PWR pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Kepka, M; Mocek, J; Barackova, L [Skoda, Plzen (Czechoslovakia)

    1980-09-01

    A survey and the chemical compositions are presented of reactor pressure vessel steels. The metallurgy is described of steel making for pressure vessels in Japan and the USSR. Both acidic and alkaline open-hearth steel is used for the manufacture of ingots. The leading world manufacturers of forging ingots for pressure vessels, however, exclusively use electric steel. Vacuum casting techniques are exclusively used. Experience is shown gained with the introduction of the manufacture of forging ingots for pressure vessels at SKODA, Plzen. The metallurgical procedure was tested utilizing alkaline open hearths, electric arc furnaces and facilities for vacuum casting of steel. Pure charge raw materials should be used for securing high steel purity. Prior to forging pressure vessel rings, not only should sufficiently big bottoms and heads be removed but also the ingot middle part should be scrapped showing higher contents of impurities and nonhomogeneous structure.

  10. Nuclear reactor vessel fuel thermal insulating barrier

    Science.gov (United States)

    Keegan, C. Patrick; Scobel, James H.; Wright, Richard F.

    2013-03-19

    The reactor vessel of a nuclear reactor installation which is suspended from the cold leg nozzles in a reactor cavity is provided with a lower thermal insulating barrier spaced from the reactor vessel that has a hemispherical lower section that increases in volume from the center line of the reactor to the outer extent of the diameter of the thermal insulating barrier and smoothly transitions up the side walls of the vessel. The space between the thermal insulating harrier and the reactor vessel forms a chamber which can be flooded with cooling water through passive valving to directly cool the reactor vessel in the event of a severe accident. The passive inlet valve for the cooling water includes a buoyant door that is normally maintained sealed under its own weight and floats open when the cavity is Hooded. Passively opening steam vents are also provided.

  11. Method of burying vessel containing radioactive waste

    International Nuclear Information System (INIS)

    Koga, Yoshihito.

    1989-01-01

    A float having an inert gas sealed therein is attached to a tightly closed vessel containing radioactive wastes. The vessel is inserted and kept in a small hole for burying the tightly closed vessel in an excavated shaft in rocks such as of granite or rock salts, while filling bentonite as shielding material therearound. In this case, the float is so adjusted that the apparent specific gravity is made equal or nearer between the tightly closed vessel and the bentonite, so that the rightly closed vessel does not sink and cause direct contact with the rocks even if bentonite flows due to earthquakes, etc. This can prevent radioactivity contamination through water in the rocks. (S.K.)

  12. An experimental study on feasibility of ex-vessel cooling through the external guide vessel

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Kim, Jong-Hwan; Park, Rae-Jun; Kim, Sang-Baik

    2000-01-01

    This paper presents the results of a series of experiments for assessing the efficacy of ex-vessel cooling through the external guide vessel during a severe accident. Four tests were performed in the LAVA test facility at KAERI, varying the boundary conditions at the outer surface of the vessel. The first test was a dry condition test conducted without cooling the outside of the vessel. On the other hand, in the second test, the cooling of the vessel surface was produced by gravity-driven forced injection of water along the annular gap of 25 mm between the vessel and the external guide vessel. Water flow rate was about 0.85 kg/s and total mass of available water was 300 kg. For the evaluation of the water flow rate effect, the third test was performed with a pool type cooling in the annulus without any circulation of water. These two external cooling tests were performed under elevated pressure of about 1.6 MPa. Finally, the fourth test was conducted under atmospheric pressure to evaluate the effect of system pressure on boiling heat transfer characteristics. In the dry test and the pool type ex-vessel cooling test performed under atmospheric pressure, the vessel was failed by a melt penetration at about 40 degree upper position from the vessel bottom, which is coincident with the boundary of the Al 2 O 3 /Fe melt separated layers. On the other hand, in both of the ex-vessel cooling tests conducted under elevated pressure of about 1.6 MPa, the vessel didn't fail. Compared with the pool boiling test, the vessel experienced effective cooling due to the inlet flow in the forced flow test. Synthesized the results of the tests, it was shown that the heat removal with ex-vessel cooling through the guide vessel is feasible, but the additional evaluations should be performed to guarantee enough thermal margin. (author)

  13. Proposals for best-quality immunohistochemical staining of paraffin-embedded brain tissue slides in forensics.

    Science.gov (United States)

    Trautz, Florian; Dreßler, Jan; Stassart, Ruth; Müller, Wolf; Ondruschka, Benjamin

    2018-01-03

    Immunohistochemistry (IHC) has become an integral part in forensic histopathology over the last decades. However, the underlying methods for IHC vary greatly depending on the institution, creating a lack of comparability. The aim of this study was to assess the optimal approach for different technical aspects of IHC, in order to improve and standardize this procedure. Therefore, qualitative results from manual and automatic IHC staining of brain samples were compared, as well as potential differences in suitability of common IHC glass slides. Further, possibilities of image digitalization and connected issues were investigated. In our study, automatic staining showed more consistent staining results, compared to manual staining procedures. Digitalization and digital post-processing facilitated direct analysis and analysis for reproducibility considerably. No differences were found for different commercially available microscopic glass slides regarding suitability of IHC brain researches, but a certain rate of tissue loss should be expected during the staining process.

  14. Preparation of colloidal gold for staining proteins electrotransferred onto nitrocellulose membranes.

    Science.gov (United States)

    Yamaguchi, K; Asakawa, H

    1988-07-01

    This paper describes a simple method of preparing colloidal gold for staining protein blots. Colloidal gold was prepared from 0.005 or 0.01% HAuCl4 by the addition of formalin as a reductant and potassium hydroxide. Staining of small cell carcinoma tissue extract blotted onto nitrocellulose membranes with this colloidal gold solution resulted in the appearance of a large number of clear wine-red bands. The sensitivity of gold staining was 60 times higher than that of Coomassie brilliant blue staining and almost comparable to that of silver staining of proteins in polyacrylamide gel. The sensitivity of this method was also satisfactory in comparison with that of enzyme immunoblotting. The colloidal gold prepared by this method is usable for routine work.

  15. Optimal staining methods for delineation of cortical areas and neuron counts in human brains.

    Science.gov (United States)

    Uylings, H B; Zilles, K; Rajkowska, G

    1999-04-01

    For cytoarchitectonic delineation of cortical areas in human brain, the Gallyas staining for somata with its sharp contrast between cell bodies and neuropil is preferable to the classical Nissl staining, the more so when an image analysis system is used. This Gallyas staining, however, does not appear to be appropriate for counting neuron numbers in pertinent brain areas, due to the lack of distinct cytological features between small neurons and glial cells. For cell counting Nissl is preferable. In an optimal design for cell counting at least both the Gallyas and the Nissl staining must be applied, the former staining for cytoarchitectural delineaton of cortical areas and the latter for counting the number of neurons in the pertinent cortical areas. Copyright 1999 Academic Press.

  16. Ocular melanoma metastatic to skin: the value of HMB-45 staining.

    Science.gov (United States)

    Schwartz, Robert A; Kist, Joseph M; Thomas, Isabelle; Fernández, Geover; Cruz, Manuel A; Koziorynska, Ewa I; Lambert, W Clark

    2004-06-01

    Cutaneous metastatic disease is an important finding that may represent the first sign of systemic cancer, or, if already known, that may change tumor staging and thus dramatically altered therapeutic plans. Although cutaneous metastases are relatively frequent in patients with cutaneous melanoma, they are less so from ocular melanoma. To demonstrate the value of HMB-45, staining in the detection of ocular melanoma metastatic to skin. The immunohistochemical stain HMB-45 a monoclonal antibody directed against intact human melanoma cells, was employed on a skin biopsy specimen from a cutaneous tumor. HMB-45 staining was positive in the atypical hyperchromatic cells of the deep dermis. HMB-45 may be of value in the detection of ocular melanoma metastatic to skin. Cutaneous metastatic disease is a somewhat common and extremely important diagnosis. Although cutaneous metastases from cutaneous melanoma are relatively frequent, those from ocular melanomas are less so. Use of histochemical staining, especially the HMB-45 stain, allows confirmation of the diagnosis.

  17. Histomorphometric comparative study of blood vessels and their pattern in follicular cyst, odontogenic keratocyst, and ameloblastoma.

    Science.gov (United States)

    Seifi, Safora; Feizi, Farideh; Khafri, Thoraya; Aram, Mehrdad

    2013-03-01

    The present study aimed at assessment and histomorphometric analysis of intratumoral and peritumoral (cystic) blood vessels in odontogenic lesions and their pattern on their clinical behavior by immunohistochemistry and morphometry. In a descriptive and analytical cross-sectional study, 45 paraffin blocks of ameloblastoma, odontogenic keratocyst, and follicular cyst were selected and stained immunohistochemically for CD34. In each slide, images of 3 microscopic fields with the highest microvessel density in intratumoral and peritumoral (cystic) areas were captured at 40× magnification with attached camera system. Inner vascular diameter (IVD) and outer vascular diameter (OVD), cross-sectional area (CSA), and the wall thickness (WT) of the vessels were measured with Motic Plus 2 software. The vascular pattern in odontogenic lesions was analyzed. Outer vascular diameter, IVD, and CSA of the vessels in peritumoral (cystic) areas were greater in ameloblastoma than keratocyst (P = 0.001) and follicular cyst (P keratocyst and follicular cyst. Morphometric specifications of blood vessels (IVD, OVD, CSA) and their pattern in peritumoral (cystic) areas may influence the aggressive clinical behavior of ameloblastoma in comparison with keratocyst and follicular cyst.

  18. Presence of intratumoral platelets is associated with tumor vessel structure and metastasis

    International Nuclear Information System (INIS)

    Li, Rong; Zhang, Xu; Zhang, Zhuo; Zhang, Xiao; Ran, Bing; Wu, Jianbo; Ren, Meiping; Chen, Ni; Luo, Mao; Deng, Xin; Xia, Jiyi; Yu, Guang; Liu, Jinbo; He, Bing

    2014-01-01

    Platelets play a fundamental role in maintaining hemostasis and have been shown to participate in hematogenous dissemination of tumor cells. Abundant platelets were detected in the tumor microenvironment outside of the blood vessel, thus, platelet -tumor cell interaction outside of the bloodstream may play a role in regulating primary tumor growth and metastasis initiation. However, it is unclear that platelet depletion affects tumor vessel structure and dynamics. Using thrombocytopenia induction in two different tumor-bearing mouse models, tumor tissues were performed by Westernblotting and immunohistochemical staining. Vascular permeability was evaluated by determination of intratumoral Evans blue and Miles vascular permeability assay. Furthermore, microdialysis was used to examining the intratumoral extracellular angiogenic growth factors (VEGF, TGF-β) by ELISA. Platelet depletion showed no change in tumor growth and reduced lung metastasis. Platelet depletion led to reduced tumor hypoxia and Met receptor activation and was associated with a decreased release of MMP-2, 9, PAI-1, VEGF, and TGF-β. Tumor vessels in platelet-depleted mice showed impaired vessel density and maturation. Our findings demonstrate that platelets within the primary tumor microenvironment play a critical role in the induction of vascular permeability and initiation of tumor metastasis

  19. The antioxidant and antiapoptotic effects of crocin pretreatment on global cerebral ischemia reperfusion injury induced by four vessels occlusion in rats.

    Science.gov (United States)

    Oruc, Serdar; Gönül, Yücel; Tunay, Kamil; Oruc, Oya Akpinar; Bozkurt, Mehmet Fatih; Karavelioğlu, Ergün; Bağcıoğlu, Erman; Coşkun, Kerem Senol; Celik, Sefa

    2016-06-01

    Cerebral ischemia reperfusion (IR) injury is a process in which oxidative and apoptotic mechanisms play a part. Neuroprotective agents to be found could work out well for the efficient and safe minimization of cerebral IR injury. Crocin is a strong antioxidant agent; however the influence of this agent on the experimental cerebral ischemia model has not been studied extensively and thus it is not well-known. The objective of our study was to investigate the antioxidant, antiapoptotic and protective effects of crocin on the global cerebral IR induced by four-vessel occlusion. A total of 30 adult female Sprague-Dawley rats were equally and randomly separated into three groups as follows: sham, IR and IR+crocin (40mg/kg/day orally for 10days). 24h after electrocauterization of bilateral vertebral arteries, bilateral common carotid arteries were occluded for 30min and reperfused for 30min. Oxidative stress parameters (TAS, TOS, OSI), haematoxylin and eosin staining, caspase-3 and hypoxia-inducible factor-1 alpha (HIF-1α) expressions and TUNEL methods were investigated. There was a significant difference between the IR and sham groups by means of OSI level, histopathological scoring, caspase-3, HIF-1α and TUNEL-positive cell parameters. We have also observed that pre-treatment with crocin reduced these parameter levels back to the baseline. The data obtained from the present study suggest that crocin may exert antiapoptotic, antioxidant and protective effects in IR-mediated brain injury induced by four-vessel occlusion. To the best of our knowledge, this would be the first study to be conducted in this field. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Correlation between expressions of hypoxia -inducible factor (HIF-1α, blood vessels density, cell proliferation, and apoptosis intensity in canine fibromas and fibrosarcomas

    Directory of Open Access Journals (Sweden)

    Madej Janusz A.

    2014-03-01

    Full Text Available The study aimed to demonstrate the expression of hypoxia-inducible factor (HIF-1α in soft tissue mesenchymal tumours (fibroma and fibrosarcoma in dogs. An attempt was made to correlate the obtained results with density of blood vessels (expression of von Willebrand Factor, vWF, expression of Ki-67 proliferation antigen, and with intensity of apoptosis in studied tumours. The study was performed on paraffin sections of 15 fibromas and 40 fibrosarcomas sampled from 55 female dogs aged 6 to 16 years. Immunohistochemical staining against HIF-1α, vWF, and Ki-67 was performed. Apoptosis was detected with the use of TUNEL reaction. A significantly higher HIF-1α expression was noted in fibrosarcomas in comparison to fibromas (P < 0.0001. HIF-1α expression in fibromas manifested strong positive correlation with tumour vascularity (r = 0.67, P = 0.007. Moreover, HIF-1α expression in fibrosarcomas manifested a moderate positive correlation with tumour malignancy grade (r = 0.44, P = 0.004, tumour vascularity (r = 0.52, P < 0.001, Ki-67 antigen expression (r = 0.42; P = 0.007, and TUNELpositive cells (r = 0.37, P = 0.017. Expression of HIF-1α was detected in 86.7% of fibroma type tumours and in 100% of fibrosarcomas. In all studied tumours expression of HIF-1α manifested positive correlation with the density of blood vessels, and in fibrosarcomas it correlated also with malignancy grade, intensity of Ki-67 expression, and with intensity of apoptosis in tumour cells.

  1. Radiation embrittlement of PWR vessel supports

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Robinson, G.C.; Pennell, W.E.; Nanstad, R.K.

    1989-01-01

    Several studies pertaining to radiation damage of PWR vessel supports were conducted between 1978 and 1987. During this period, apparently there was no reason to believe that low-temperature (<100 degree C) MTR embrittlement data were not appropriate for evaluating embrittlement of PWR vessel supports. However, late in 1986, data from the High Flux Isotope Reactor (HFIR) vessel surveillance program indicated that the embrittlement rates of the several HFIR vessel materials (A212-B, A350-LF3, A105-II) were substantially greater than anticipated on the basis of MTR data. Further evaluation of the HFIR data suggested that a fluence-rate effect was responsible for the apparent discrepancy, and shortly thereafter it became apparent that this rate effect was applicable to the evaluation of LWR vessel supports. As a result, the Nuclear Regulatory Commission (NRC) requested that the Oak Ridge National Laboratory (ORNL) evaluate the impact of the apparent embrittlement rate effect on the integrity of light-water-reactor (LWR) vessel supports. The purpose of the study was to provide an indication of whether the integrity of reactor vessel supports is likely to be challenged by radiation-induced embrittlement. The scope of the evaluation included correlation of the HFIR data for application to the evaluation of LWR vessel supports; a survey and cursory evaluation of all US LWR vessel support designs, selection of two plants for specific-plant evaluation, and a specific-plant evaluation of both plants to determine critical flaw sizes for their vessel supports. 19 refs., 8 figs., 2 tabs

  2. Should gram stains have a role in diagnosing hip arthroplasty infections?

    Science.gov (United States)

    Johnson, Aaron J; Zywiel, Michael G; Stroh, D Alex; Marker, David R; Mont, Michael A

    2010-09-01

    The utility of Gram stains in diagnosing periprosthetic infections following total hip arthroplasty has recently been questioned. Several studies report low sensitivity of the test, and its poor ability to either confirm or rule out infection in patients undergoing revision total hip arthroplasty. Despite this, many institutions including that of the senior author continue to perform Gram stains during revision total hip arthroplasty. We assessed the sensitivity, specificity, accuracy, and positive and negative predictive values of Gram stains from surgical-site samplings taken from procedures on patients with both infected and aseptic revision total hip arthroplasties. A review was performed on patients who underwent revision total hip arthroplasty between 2000 and 2007. Eighty-two Gram stains were performed on patients who had infected total hip arthroplasties and underwent revision procedures. Additionally, of the 410 revision total hip arthroplasties performed on patients who were confirmed infection-free, 120 Gram stains were performed. Patients were diagnosed as infected using multiple criteria at the time of surgery. Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from these Gram stain results. The Gram stain demonstrated a sensitivity and specificity of 9.8% and 100%, respectively. In this series, the Gram stain had a negative predictive value of 62%, a positive predictive value of 100%, and an accuracy of 63%. Gram stains obtained from surgical-site samples had poor sensitivity and poor negative predictive value. Based on these findings, as well as those of other authors, we believe that Gram stains should no longer be considered for diagnosing infections in revision total hip arthroplasty. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.

  3. Porcine intestinal mast cells. Evaluation of different fixatives for histochemical staining techniques considering tissue shrinkage

    Directory of Open Access Journals (Sweden)

    J. Rieger

    2013-07-01

    Full Text Available Staining of mast cells (MCs, including porcine ones, is critically dependent upon the fixation and staining technique. In the pig, mucosal and submucosal MCs do not stain or stain only faintly after formalin fixation. Some fixation methods are particularly recommended for MC staining, for example the fixation with Carnoy or lead salts. Zinc salt fixation (ZSF has been reported to work excellently for the preservation of fixation-sensitive antigens. The aim of this study was to establish a reliable histological method for counting of MCs in the porcine intestinum. For this purpose, different tissue fixation and staining methods that also allow potential subsequent immunohistochemical investigations were evaluated in the porcine mucosa, as well as submucosa of small and large intestine. Tissues were fixed in Carnoy, lead acetate, lead nitrate, Zamboni and ZSF and stained subsequently with either polychromatic methylene blue, alcian blue or toluidine blue. For the first time our study reveals that ZSF, a heavy metal fixative, preserves metachromatic staining of porcine MCs. Zamboni fixation was not suitable for histochemical visualization of MCs in the pig intestine. All other tested fixatives were suitable. Alcian blue and toluidine blue co-stained intestinal goblet cells which made a prima facie identification of MCs difficult. The polychromatic methylene blue proved to be the optimal staining. In order to compare MC counting results of the different fixation methods, tissue shrinkage was taken into account. As even the same fixation caused shrinkage-differences between tissue from small and large intestine, different factors for each single fixation and intestinal localization had to be calculated. Tissue shrinkage varied between 19% and 57%, the highest tissue shrinkage was found after fixation with ZSF in the large intestine, the lowest one in the small intestine after lead acetate fixation. Our study emphasizes that MC counting results from

  4. ITER vacuum vessel, in vessel components and plasma facing materials

    International Nuclear Information System (INIS)

    Ioki, Kimihiro; Enoeda, M.; Federici, G.

    2007-01-01

    Design of the NB ports including duct liners under heat loads of the neutral beams has been developed. Design of the in-wall shielding has been developed in more details considering the supporting structure and the assembly method. The ferromagnetic inserts have previously not been installed in the outboard midplane region due to irregularity caused by the tangential ports for NB injection. Due to this configuration, the maximum ripple is relatively large (∝1 %) in a limited region of the plasma and the toroidal field flux lines fluctuate ∝10 mm in the FW region. To avoid these problems, additional ferromagnetic inserts are to be installed in the equatorial port region. Detailed studies were carried out on the ITER vacuum vessel to define appropriate codes and standards in the context of the ITER licensing in France. A set of draft documents regarding the ITER vacuum vessel structural code were prepared including an RCC-MR Addendum for the ITER VV with justified exceptions or modifications. The main deviation from the base Code is the extensive use of UT in lieu of radiography for the volumetric examination of all one-side access welds of the outer shell and field joint. The procurement allocation of blanket modules among 6 parties was fixed and the blanket module design has progressed in cooperation with parties. Fabrication of mock-ups for prequalification testing is under way and the tests will be performed in 2007-2008. Development of new beryllium materials is progressing in China and Russia. The ITER limiters will be installed in equatorial ports at two toroidal locations. The limiter plasma-facing surface protrudes ∝8 cm from the FW during the start-up and shutdown phase. In the new limiter concept, the limiters are retracted by ∝8 cm during the plasma flat top phase. This concept gives important advantages; (i) mitigation of the particle and heat loads due to disruptions, ELMs and blobs, (ii) improvement of the power coupling with the ICRH antenna

  5. Reactor pressure vessel. Status report

    International Nuclear Information System (INIS)

    Elliot, B.J.; Hackett, E.M.; Lee, A.D.

    1996-10-01

    This report describes the issues raised as a result of the staffs review of Generic Letter (GL) 92-01, Revision 1, responses and plant-specific reactor pressure vessel (RPV) assessments and the actions taken or work in progress to address these issues. In addition, the report describes actions taken by the staff and the nuclear industry to develop a thermal annealing process for use at U.S. commercial nuclear power plants. This process is intended to be used as a means of mitigating the effects of neutron radiation on the fracture toughness of RPV materials. The Nuclear Regulatory Commission (NRC) issued GL 92-01, Revision 1, Supplement 1, to obtain information needed to assess compliance with regulatory requirements and licensee commitments regarding RPV integrity. GL 92-01, Revision 1, Supplement 1, was issued as a result of generic issues that were raised in the NRC staff's reviews of licensee responses to GL 92-01, Revision 1, and plant-specific RPV evaluations. In particular, an integrated review of all data submitted in response to GL 92-01, Revision 1, indicated that licensees may not have considered all relevant data in their RPV assessments. This report is representative of submittals to and evaluations by the staff as of September 30, 1996. An update of this report will be issued at a later date

  6. ITER vacuum vessel structural analysis completion during manufacturing phase

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, J.-M., E-mail: jean-marc.martinez@live.fr [ITER Organization, Route Vinon sur Verdon, CS 90046, 13067, St. Paul lez Durance, Cedex (France); Alekseev, A.; Sborchia, C.; Choi, C.H.; Utin, Y.; Jun, C.H.; Terasawa, A.; Popova, E.; Xiang, B.; Sannazaro, G.; Lee, A.; Martin, A.; Teissier, P.; Sabourin, F. [ITER Organization, Route Vinon sur Verdon, CS 90046, 13067, St. Paul lez Durance, Cedex (France); Caixas, J.; Fernandez, E.; Zarzalejos, J.M. [F4E, c/Josep Pla, n.2, Torres Diagonal Litoral, Edificio B3, E-08019, Barcelona (Spain); Kim, H.-S.; Kim, Y.G. [ITER Korea, National Fusion Research Institute, Daejeon (Korea, Republic of); Privalova, E. [NTC “Sintez”, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); and others

    2016-11-01

    Highlights: • ITER Vacuum Vessel (VV) is a part of the first barrier to confine the plasma. • A Nuclear Pressure Equipment necessitates Agreed Notified Body to assure design, fabrication, and conformance testing and quality assurance. • Some supplementary RCC-MR margin targets have been considered to guarantee considerable structural margins in areas not inspected in operation. • Many manufacturing deviation requests (MDR) and project change requests (PCR) impose to re-evaluate the structural margin. • Several structural analyses were performed with global and local models to guarantee the structural integrity of the whole ITER Vacuum Vessel. - Abstract: Some years ago, analyses were performed by ITER Organization Central Team (IO-CT) to verify the structural integrity of the ITER vacuum vessel baseline design fixed in 2010 and classified as a Protection Important Component (PIC). The manufacturing phase leads the ITER Organization domestic agencies (IO-DA) and their contracted manufacturers to propose detailed design improvements to optimize the manufacturing or inspection process. These design and quality inspection changes can affect the structural margins with regards to the Codes&Standards and thus oblige to evaluate one more time the modified areas. This paper proposes an overview of the additional analyses already performed to guarantee the structural integrity of the manufacturing designs. In this way, CT and DAs have been strongly involved to keep the considerable margins obtained previously which were used to fix reasonable compensatory measures for the lack of In Service Inspections of a Nuclear Pressure Equipment (NPE).

  7. Reactor water spontaneous circulation structure in reactor pressure vessel

    International Nuclear Information System (INIS)

    Takahashi, Kazumi

    1998-01-01

    The gap between the inner wall of a reactor pressure vessel of a BWR type reactor and a reactor core shroud forms a down comer in which reactor water flows downwardly. A feedwater jacket to which feedwater at low temperature is supplied is disposed at the outer circumference of the pressure vessel just below a gas/water separator. The reactor water at the outer circumferential portion just below the air/water separator is cooled by the feedwater jacket, and the feedwater after cooling is supplied to the feedwater entrance disposed below the feedwater jacket by way of a feedwater introduction line to supply the feedwater to the lower portion of the down comer. This can cool the reactor water in the down comer to increase the reactor water density in the down comer thereby forming strong downward flows and promote the recycling of the reactor water as a whole. With such procedures, the reactor water can be recycled stably only by the difference of the specific gravity of the reactor water without using an internal pump. In addition, the increase of the height of the pressure vessel can be suppressed. (I.N.)

  8. ITER vacuum vessel structural analysis completion during manufacturing phase

    International Nuclear Information System (INIS)

    Martinez, J.-M.; Alekseev, A.; Sborchia, C.; Choi, C.H.; Utin, Y.; Jun, C.H.; Terasawa, A.; Popova, E.; Xiang, B.; Sannazaro, G.; Lee, A.; Martin, A.; Teissier, P.; Sabourin, F.; Caixas, J.; Fernandez, E.; Zarzalejos, J.M.; Kim, H.-S.; Kim, Y.G.; Privalova, E.

    2016-01-01

    Highlights: • ITER Vacuum Vessel (VV) is a part of the first barrier to confine the plasma. • A Nuclear Pressure Equipment necessitates Agreed Notified Body to assure design, fabrication, and conformance testing and quality assurance. • Some supplementary RCC-MR margin targets have been considered to guarantee considerable structural margins in areas not inspected in operation. • Many manufacturing deviation requests (MDR) and project change requests (PCR) impose to re-evaluate the structural margin. • Several structural analyses were performed with global and local models to guarantee the structural integrity of the whole ITER Vacuum Vessel. - Abstract: Some years ago, analyses were performed by ITER Organization Central Team (IO-CT) to verify the structural integrity of the ITER vacuum vessel baseline design fixed in 2010 and classified as a Protection Important Component (PIC). The manufacturing phase leads the ITER Organization domestic agencies (IO-DA) and their contracted manufacturers to propose detailed design improvements to optimize the manufacturing or inspection process. These design and quality inspection changes can affect the structural margins with regards to the Codes&Standards and thus oblige to evaluate one more time the modified areas. This paper proposes an overview of the additional analyses already performed to guarantee the structural integrity of the manufacturing designs. In this way, CT and DAs have been strongly involved to keep the considerable margins obtained previously which were used to fix reasonable compensatory measures for the lack of In Service Inspections of a Nuclear Pressure Equipment (NPE).

  9. Concrete benchmark experiment: ex-vessel LWR surveillance dosimetry

    International Nuclear Information System (INIS)

    Ait Abderrahim, H.; D'Hondt, P.; Oeyen, J.; Risch, P.; Bioux, P.

    1993-09-01

    The analysis of DOEL-1 in-vessel and ex-vessel neutron dosimetry, using the DOT 3.5 Sn code coupled with the VITAMIN-C cross-section library, showed the same C/E values for different detectors at the surveillance capsule and the ex-vessel cavity positions. These results seem to be in contradiction with those obtained in several Benchmark experiments (PCA, PSF, VENUS...) when using the same computational tools. Indeed a strong decreasing radial trend of the C/E was observed, partly explained by the overestimation of the iron inelastic scattering. The flat trend seen in DOEL-1 could be explained by compensating errors in the calculation such as the backscattering due to the concrete walls outside the cavity. The 'Concrete Benchmark' experiment has been designed to judge the ability of this calculation methods to treat the backscattering. This paper describes the 'Concrete Benchmark' experiment, the measured and computed neutron dosimetry results and their comparison. This preliminary analysis seems to indicate an overestimation of the backscattering effect in the calculations. (authors). 5 figs., 1 tab., 7 refs

  10. AN EFFICIENT TECHNIQUE FOR RETINAL VESSEL SEGMENTATION AND DENOISING USING MODIFIED ISODATA AND CLAHE

    Directory of Open Access Journals (Sweden)

    Khan Bahadar Khan

    2016-11-01

    Full Text Available Retinal damage caused due to complications of diabetes is known as Diabetic Retinopathy (DR. In this case, the vision is obscured due to the damage of retinal tinny blood vessels of the retina. These tinny blood vessels may cause leakage which affect the vision and can lead to complete blindness. Identification of these new retinal vessels and their structure is essential for analysis of DR. Automatic blood vessels segmentation plays a significant role to assist subsequent automatic methodologies that aid to such analysis. In literature most of the people have used computationally hungry a strong preprocessing steps followed by a simple thresholding and post processing, But in our proposed technique we utilize an arrangement of  light pre-processing which consists of Contrast Limited Adaptive Histogram Equalization (CLAHE for contrast enhancement, a difference image of green channel from its Gaussian blur filtered image to remove local noise or geometrical object, Modified Iterative Self Organizing Data Analysis Technique (MISODATA for segmentation of vessel and non-vessel pixels based on global and local thresholding, and a strong  post processing using region properties (area, eccentricity to eliminate the unwanted region/segment, non-vessel pixels and noise that never been used to reject misclassified foreground pixels. The strategy is tested on the publically accessible DRIVE (Digital Retinal Images for Vessel Extraction and STARE (STructured Analysis of the REtina databases. The performance of proposed technique is assessed comprehensively and the acquired accuracy, robustness, low complexity and high efficiency and very less computational time that make the method an efficient tool for automatic retinal image analysis. Proposed technique perform well as compared to the existing strategies on the online available databases in term of accuracy, sensitivity, specificity, false positive rate, true positive rate and area under receiver

  11. Strong coupling phase in QED

    International Nuclear Information System (INIS)

    Aoki, Ken-ichi

    1988-01-01

    Existence of a strong coupling phase in QED has been suggested in solutions of the Schwinger-Dyson equation and in Monte Carlo simulation of lattice QED. In this article we recapitulate the previous arguments, and formulate the problem in the modern framework of the renormalization theory, Wilsonian renormalization. This scheme of renormalization gives the best understanding of the basic structure of a field theory especially when it has a multi-phase structure. We resolve some misleading arguments in the previous literature. Then we set up a strategy to attack the strong phase, if any. We describe a trial; a coupled Schwinger-Dyson equation. Possible picture of the strong coupling phase QED is presented. (author)

  12. An optimized staining technique for the detection of Gram positive and Gram negative bacteria within tissue.

    Science.gov (United States)

    Becerra, Sandra C; Roy, Daniel C; Sanchez, Carlos J; Christy, Robert J; Burmeister, David M

    2016-04-12

    Bacterial infections are a common clinical problem in both acute and chronic wounds. With growing concerns over antibiotic resistance, treatment of bacterial infections should only occur after positive diagnosis. Currently, diagnosis is delayed due to lengthy culturing methods which may also fail to identify the presence of bacteria. While newer costly bacterial identification methods are being explored, a simple and inexpensive diagnostic tool would aid in immediate and accurate treatments for bacterial infections. Histologically, hematoxylin and eosin (H&E) and Gram stains have been employed, but are far from optimal when analyzing tissue samples due to non-specific staining. The goal of the current study was to develop a modification of the Gram stain that enhances the contrast between bacteria and host tissue. A modified Gram stain was developed and tested as an alternative to Gram stain that improves the contrast between Gram positive bacteria, Gram negative bacteria and host tissue. Initially, clinically relevant strains of Pseudomonas aeruginosa and Staphylococcus aureus were visualized in vitro and in biopsies of infected, porcine burns using routine Gram stain, and immunohistochemistry techniques involving bacterial strain-specific fluorescent antibodies as validation tools. H&E and Gram stain of serial biopsy sections were then compared to a modification of the Gram stain incorporating a counterstain that highlights collagen found in tissue. The modified Gram stain clearly identified both Gram positive and Gram negative bacteria, and when compared to H&E or Gram stain alone provided excellent contrast between bacteria and non-viable burn eschar. Moreover, when applied to surgical biopsies from patients that underwent burn debridement this technique was able to clearly detect bacterial morphology within host tissue. We describe a modification of the Gram stain that provides improved contrast of Gram positive and Gram negative microorganisms within host

  13. Strong interactions at high energy

    International Nuclear Information System (INIS)

    Anselmino, M.

    1995-01-01

    Spin effects in strong interaction high energy processes are subtle phenomena which involve both short and long distance physics and test perturbative and non perturbative aspects of QCD. Moreover, depending on quantities like interferences between different amplitudes and relative phases, spin observables always test a theory at a fundamental quantum mechanical level; it is then no surprise that spin data are often difficult to accommodate within the existing models. A report is made on the main issues and contributions discussed in the parallel Session on the open-quote open-quote Strong interactions at high energy close-quote close-quote in this Conference. copyright 1995 American Institute of Physics

  14. Strong-field dissociation dynamics

    International Nuclear Information System (INIS)

    DiMauro, L.F.; Yang, Baorui.

    1993-01-01

    The strong-field dissociation behavior of diatomic molecules is examined under two distinctive physical scenarios. In the first scenario, the dissociation of the isolated hydrogen and deuterium molecular ions is discussed. The dynamics of above-threshold dissociation (ATD) are investigated over a wide range of green and infrared intensities and compared to a dressed-state model. The second situation arises when strong-field neutral dissociation is followed by ionization of the atomic fragments. The study results in a direct measure of the atomic fragment's ac-Stark shift by observing the intensity-dependent shifts in the electron or nuclear fragment kinetic energy. 8 figs., 14 refs

  15. 78 FR 40891 - Revisions to the Export Administration Regulations: Military Vehicles; Vessels of War...

    Science.gov (United States)

    2013-07-08

    ... Vehicles; Vessels of War; Submersible Vessels, Oceanographic Equipment; Related Items; and Auxiliary and... Regulations: Military Vehicles; Vessels of War; Submersible Vessels, Oceanographic Equipment; Related Items... military vehicles and related items; vessels of war and related items; submersible vessels, oceanographic...

  16. Design of the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.

    1995-01-01

    The ITER vacuum vessel is a major safety barrier and must support electromagnetic loads during plasma disruptions and vertical displacement events (VDE) and withstand plausible accidents without losing confinement.The vacuum vessel has a double wall structure to provide structural and electrical continuity in the toroidal direction. The inner and outer shells and poloidal stiffening ribs between them are joined by welding, which gives the vessel the required mechanical strength. The space between the shells will be filled with steel balls and plate inserts to provide additional nuclear shielding. Water flowing in this space is required to remove nuclear heat deposition, which is 0.2-2.5% of the total fusion power. The minor and major radii of the tokamak are 3.9 m and 13 m respectively, and the overall height is 15 m. The total thickness of the vessel wall structure is 0.4-0.7 m.The inboard and outboard blanket segments are supported from the vacuum vessel. The support structure is required to withstand a large total vertical force of 200-300 MN due to VDE and to allow for differential thermal expansion.The first candidate for the vacuum vessel material is Inconel 625, due to its higher electric resistivity and higher yield strength, even at high temperatures. Type 316 stainless steel is also considered a vacuum vessel material candidate, owing to its large database and because it is supported by more conventional fabrication technology. (orig.)

  17. Assessment of reactor vessel integrity (ARVI)

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R. E-mail: sehgal@ne.kth.se; Theerthan, A.; Giri, A.; Karbojian, A.; Willschuetz, H.G.; Kymaelaeinen, O.; Vandroux, S.; Bonnet, J.M.; Seiler, J.M.; Ikkonen, K.; Sairanen, R.; Bhandari, S.; Buerger, M.; Buck, M.; Widmann, W.; Dienstbier, J.; Techy, Z.; Kostka, P.; Taubner, R.; Theofanous, T.; Dinh, T.N

    2003-04-01

    The cost-shared project ARVI (assessment of reactor vessel integrity) involves a total of nine organisations from Europe and USA. The objective of the ARVI Project is to resolve the safety issues that remain unresolved for the melt vessel interaction phase of the in-vessel progression of a severe accident. The work consists of experiments and analysis development. Four tests were performed in the EC-FOREVER Programme, in which failure was achieved in-vessels employing the French pressure vessel steel. The tests were analysed with the commercial code ANSYS-Multiphysics, and the codes SYSTUS+ and PASULA, and quite good agreement was achieved for the failure location. Natural convection experiments in stratified pools have been performed in the SIMECO and the COPO facilities, which showed that much greater heat is transferred downwards for immiscible layers or before layers mix. A model for gap cooling and a set of simplified models for the system codes have been developed. MVITA code calculations have been performed for the Czech and Hungarian VVERs, towards evaluation of the in-vessel melt retention accident management scheme. Tests have been performed at the ULPU facility with organised flow for vessel external cooling. Considerable enhancement of the critical heat flux (CHF) was obtained. The ARVI Project has reached the halfway stage. This paper presents the results obtained thus far from the project.

  18. Flexible Composite-Material Pressure Vessel

    Science.gov (United States)

    Brown, Glen; Haggard, Roy; Harris, Paul A.

    2003-01-01

    A proposed lightweight pressure vessel would be made of a composite of high-tenacity continuous fibers and a flexible matrix material. The flexibility of this pressure vessel would render it (1) compactly stowable for transport and (2) more able to withstand impacts, relative to lightweight pressure vessels made of rigid composite materials. The vessel would be designed as a structural shell wherein the fibers would be predominantly bias-oriented, the orientations being optimized to make the fibers bear the tensile loads in the structure. Such efficient use of tension-bearing fibers would minimize or eliminate the need for stitching and fill (weft) fibers for strength. The vessel could be fabricated by techniques adapted from filament winding of prior composite-material vessels, perhaps in conjunction with the use of dry film adhesives. In addition to the high-bias main-body substructure described above, the vessel would include a low-bias end substructure to complete coverage and react peak loads. Axial elements would be overlaid to contain damage and to control fiber orientation around side openings. Fiber ring structures would be used as interfaces for connection to ancillary hardware.

  19. A confocal scanning laser ophthalmoscope for retinal vessel oximetry

    Science.gov (United States)

    Lompado, Arthur

    Measurement of a person's blood oxygen saturation has long been recognized as a useful metric for the characterizing ailments ranging from chronic respiratory disorders to acute, potentially life threatening, traumas. The ubiquity of oxygen saturation monitors in the medical field, including portable pulse oximeters and laboratory based CO-oximeters, is a testament to the importance of this technique. The work presented here documents the design, fabrication and development of a unique type of oxygen saturation monitor, a confocal scanning retinal vessel oximeter, with the potential to expand the usefulness of the present devices. A large part of the knowledge base required to construct the instrument comes from the consideration of light scattering by red blood cells in a blood vessel. Therefore, a substantial portion of this work is devoted to the process of light scattering by whole human blood and its effects on the development of a more accurate oximeter. This light scattering effect has been both measured and modeled stochastically to determine its contribution to the measured oximeter signal. It is shown that, although well accepted in the published literature, the model only correlates marginally to the measurements due to inherent limitations imposed by the model assumptions. Nonetheless, enough material has been learned about the scattering to allow development of a mathematical model for the interaction of light with blood in a vessel, and this knowledge has been applied to the data reduction of the present oximeter. This data reduction technique has been tested in a controlled experiment employing a model eye with a blood filled mock retinal vessel. It will be shown that the presently developed technique exhibited strong correlation between the known blood oxygen saturation and that calculated by the new system.

  20. Offshore wind transport and installation vessel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The initial objective of the project was to complete a feasibility study to determine the viability of an innovative transportation vessel to be deployed in the installation of offshore wind farms. This included the feasibility of providing a stable-working platform that can be used in harsh offshore environments. A study of current installation contractors and their installation equipment was used to provide a preliminary specification for the installation vessel. A typical barge was selected and a number of hydrodynamic analyses were carried out in order to establish it's on course and operational stability. The analysis proved the stability of the vessel during operation was critical and that in order to utilise the crane's full potential a stabilisation system must be employed. The main aim of the work to date was to establish whether it was feasible to use a stabilisation system on the installation vessel. The spud leg FEED study established that it was feasible to use spud legs to stabilise the vessel. In order to achieve the degree of stability required it is necessary to lift the vessel completely out of the water. This was not the original aim of the study but due to the external loads on the hull it was the only viable option. Lifting the vessel out of the water results in the legs and leg casings becoming very large. This has a number of consequences for the final design. Due to large loads on the legs spud cans must be used to avoid bottom penetration, the spud cans increase the draft of the vessel by 2m. The large loads require larger winches and more reeving to be used, this results in larger pumps and motors, all of which have to be housed. The stabilisation system has been proved to be feasible for a large installation vessel, the cost and physical size are however more excessive than first anticipated. (Author)