WorldWideScience

Sample records for strongly compressed resulting

  1. Rotating compressible fluids under strong stratification

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard; Lu, Y.; Novotný, A.

    2014-01-01

    Roč. 19, October (2014), s. 11-18 ISSN 1468-1218 Keywords : rotating fluid * compressible Navier-Stokes * strong stratification Subject RIV: BA - General Mathematics Impact factor: 2.519, year: 2014 http://www.sciencedirect.com/science/article/pii/S1468121814000212#

  2. Electromotive force in strongly compressible magnetohydrodynamic turbulence

    Science.gov (United States)

    Yokoi, N.

    2017-12-01

    Variable density fluid turbulence is ubiquitous in geo-fluids, not to mention in astrophysics. Depending on the source of density variation, variable density fluid turbulence may be divided into two categories: the weak compressible (entropy mode) turbulence for slow flow and the strong compressible (acoustic mode) turbulence for fast flow. In the strong compressible turbulence, the pressure fluctuation induces a strong density fluctuation ρ ', which is represented by the density variance ( denotes the ensemble average). The turbulent effect on the large-scale magnetic-field B induction is represented by the turbulent electromotive force (EMF) (u': velocity fluctuation, b': magnetic-field fluctuation). In the usual treatment in the dynamo theory, the expression for the EMF has been obtained in the framework of incompressible or weak compressible turbulence, where only the variation of the mean density , if any, is taken into account. We see from the equation of the density fluctuation ρ', the density variance is generated by the large mean density variation ∂ coupled with the turbulent mass flux . This means that in the region where the mean density steeply changes, the density variance effect becomes relevant for the magnetic field evolution. This situation is typically the case for phenomena associated with shocks and compositional discontinuities. With the aid of the analytical theory of inhomogeneous compressible magnetohydrodynamic (MHD) turbulence, the expression for the turbulent electromotive force is investigated. It is shown that, among others, an obliqueness (misalignment) between the mean density gradient ∂ and the mean magnetic field B may contribute to the EMF as ≈χ B×∂ with the turbulent transport coefficient χ proportional to the density variance (χ ). This density variance effect is expected to strongly affect the EMF near the interface, and changes the transport properties of turbulence. In the case of an interface under the MHD slow

  3. Geometric Results for Compressible Magnetohydrodynamics

    OpenAIRE

    Arter, Wayne

    2013-01-01

    Recently, compressible magnetohydrodynamics (MHD) has been elegantly formulated in terms of Lie derivatives. This paper exploits the geometrical properties of the Lie bracket to give new insights into the properties of compressible MHD behaviour, both with and without feedback of the magnetic field on the flow. These results are expected to be useful for the solution of MHD equations in both tokamak fusion experiments and space plasmas.

  4. Compressed Representations of Conjunctive Query Results

    OpenAIRE

    Deep, Shaleen; Koutris, Paraschos

    2017-01-01

    Relational queries, and in particular join queries, often generate large output results when executed over a huge dataset. In such cases, it is often infeasible to store the whole materialized output if we plan to reuse it further down a data processing pipeline. Motivated by this problem, we study the construction of space-efficient compressed representations of the output of conjunctive queries, with the goal of supporting the efficient access of the intermediate compressed result for a giv...

  5. Spin quenching assisted by a strongly anisotropic compression behavior in MnP

    Energy Technology Data Exchange (ETDEWEB)

    Han, Fei; Wang, Di; Wang, Yonggang; Li, Nana; Bao, Jin-Ke; Li, Bing; Botana, Antia S.; Xiao, Yuming; Chow, Paul; Chung, Duck Young; Chen, Jiuhua; Wan, Xiangang; Kanatzidis, Mercouri G.; Yang, Wenge; Mao, Ho-Kwang

    2018-02-01

    We studied the crystal structure and spin state of MnP under high pressure with synchrotron X-ray diffraction and X-ray emission spectroscopy. MnP has an exceedingly strong anisotropy in compressibility, with the primary compressible direction along the b axis of the Pnma structure. X-ray emission spectroscopy reveals a pressure-driven quenching of the spin state in MnP. First-principles calculations suggest that the strongly anisotropic compression behavior significantly enhances the dispersion of the Mn d-orbitals and the splitting of the d-orbital levels compared to the hypothetical isotropic compression behavior. Thus, we propose spin quenching results mainly from the significant enhancement of the itinerancy of d electrons and partly from spin rearrangement occurring in the split d-orbital levels near the Fermi level. This explains the fast suppression of magnetic ordering in MnP under high pressure. The spin quenching lags behind the occurrence of superconductivity at ~8 GPa implying that spin fluctuations govern the electron pairing for superconductivity.

  6. Orientation dependent slip and twinning during compression and tension of strongly textured magnesium AZ31 alloy

    Energy Technology Data Exchange (ETDEWEB)

    Al-Samman, T., E-mail: al-samman@imm.rwth-aachen.de [Institut fuer Metallkunde und Metallphysik, RWTH Aachen, Kopernikusstr. 14, D-52064 Aachen (Germany); Li, X. [Institut fuer Metallkunde und Metallphysik, RWTH Aachen, Kopernikusstr. 14, D-52064 Aachen (Germany); Chowdhury, S. Ghosh [CSIR National Metallurgical Laboratory, MST Division, Jamshedpur 831007 (India)

    2010-06-15

    Over recent years there have been a remarkable number of studies dealing with compression of magnesium. A literature search, however, shows a noticeably less number of papers concerned with tension and a very few papers comparing both modes, systematically, in one study. The current investigation reports the anisotropic deformation behavior and concomitant texture and microstructure evolution investigated in uniaxial tension and compression tests in two sample directions performed on an extruded commercial magnesium alloy AZ31 at different Z conditions. For specimens with the loading direction parallel to the extrusion axis, the tension-compression strength anisotropy was pronounced at high Z conditions. Loading at 45{sup o} from the extrusion axis yielded a tension-compression strength behavior that was close to isotropic. During tensile loading along the extrusion direction the extrusion texture resists twinning and favors prismatic slip (contrary to compression). This renders the shape change maximum in the basal plane and equal to zero along the c-axis, which resulted in the orientation of individual grains remaining virtually intact during all tension tests at different Z conditions. For the other investigated sample direction, straining was accommodated along the c-axis, which was associated with a lattice rotation, and thus, a change of crystal orientation. Uniaxial compression at a low Z condition (400 deg. C/10{sup -4} s{sup -1}) yielded a desired texture degeneration, which was explained on the basis of a more homogeneous partitioning of slip systems that reduces anisotropy and enhanced dynamic recrystallization (DRX), which counteracts the strong deformation texture. The critical strains for the nucleation of DRX in tensiled specimens at the highest investigated Z condition (200 deg. C/10{sup -2} s{sup -1}) were found to range between 4% and 5.6%.

  7. COMPRESSIBLE RELATIVISTIC MAGNETOHYDRODYNAMIC TURBULENCE IN MAGNETICALLY DOMINATED PLASMAS AND IMPLICATIONS FOR A STRONG-COUPLING REGIME

    Energy Technology Data Exchange (ETDEWEB)

    Takamoto, Makoto [Department of Earth and Planetary Science, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo, 113-0033 (Japan); Lazarian, Alexandre, E-mail: mtakamoto@eps.s.u-tokyo.ac.jp, E-mail: alazarian@facstaff.wisc.edu [Department of Astronomy, University of Wisconsin, 475 North Charter Street, Madison, WI 53706 (United States)

    2016-11-10

    In this Letter, we report compressible mode effects on relativistic magnetohydrodynamic (RMHD) turbulence in Poynting-dominated plasmas using three-dimensional numerical simulations. We decomposed fluctuations in the turbulence into 3 MHD modes (fast, slow, and Alfvén) following the procedure of mode decomposition in Cho and Lazarian, and analyzed their energy spectra and structure functions separately. We also analyzed the ratio of compressible mode to Alfvén mode energy with respect to its Mach number. We found the ratio of compressible mode increases not only with the Alfvén Mach number, but also with the background magnetization, which indicates a strong coupling between the fast and Alfvén modes. It also signifies the appearance of a new regime of RMHD turbulence in Poynting-dominated plasmas where the fast and Alfvén modes are strongly coupled and, unlike the non-relativistic MHD regime, cannot be treated separately. This finding will affect particle acceleration efficiency obtained by assuming Alfvénic critical-balance turbulence and can change the resulting photon spectra emitted by non-thermal electrons.

  8. Long term results of compression sclerotherapy.

    Science.gov (United States)

    Labas, P; Ohradka, B; Cambal, M; Reis, R; Fillo, J

    2003-01-01

    To compare the short and long term results of different techniques of compression sclerotherapy. In the past 10 years the authors treated 1622 pts due to chronic venous insufficiency. There were 3 groups of patients: 1) Pts treated by Sigg's technique using Aethoxysclerol, 2) Pts treated by Fegan's technique with Fibrovein, and 3) Pts treated by Fegan's procedure, but using a combination of both sclerosants. In all cases, the techniques of empty vein, bubble air, uninterrupted 6-week compression and forced mobilisation were used. In the group of pats. treated by Sigg's procedure, the average cure rate was 67.47% after 6 months, 60.3% after 5 years of follow-up. In Fegan's group this rate was 83.6% after 6 months and 78.54% after 5 year assessment. Statistically, significant differences were found only by the disappearance of varices and reduction of pain in favour of Fegan's technique. In the group of pts treated by Fegan's (Aethoxysclerol + Fibrovein) this rate after 5 years was 86%. The only statistically significant difference was found by the disappearance of varices in favour of Fegan's technique using a combination of 2 detergent sclerosants. Sclerotherapy is effective when properly executed in any length of vein no matter how dilated it has become. The recurrences are attributed more to inadequate technique than to the shortcoming of the procedure. Sclerotherapy is miniinvasive, with few complications, and can be repeated on out-patient basis. (Tab. 1, Ref. 22.).

  9. Results of subscale MTF compression experiments

    Science.gov (United States)

    Howard, Stephen; Mossman, A.; Donaldson, M.; Fusion Team, General

    2016-10-01

    In magnetized target fusion (MTF) a magnetized plasma torus is compressed in a time shorter than its own energy confinement time, thereby heating to fusion conditions. Understanding plasma behavior and scaling laws is needed to advance toward a reactor-scale demonstration. General Fusion is conducting a sequence of subscale experiments of compact toroid (CT) plasmas being compressed by chemically driven implosion of an aluminum liner, providing data on several key questions. CT plasmas are formed by a coaxial Marshall gun, with magnetic fields supported by internal plasma currents and eddy currents in the wall. Configurations that have been compressed so far include decaying and sustained spheromaks and an ST that is formed into a pre-existing toroidal field. Diagnostics measure B, ne, visible and x-ray emission, Ti and Te. Before compression the CT has an energy of 10kJ magnetic, 1 kJ thermal, with Te of 100 - 200 eV, ne 5x1020 m-3. Plasma was stable during a compression factor R0/R >3 on best shots. A reactor scale demonstration would require 10x higher initial B and ne but similar Te. Liner improvements have minimized ripple, tearing and ejection of micro-debris. Plasma facing surfaces have included plasma-sprayed tungsten, bare Cu and Al, and gettering with Ti and Li.

  10. Hall effect in a strong magnetic field: Direct comparisons of compressible magnetohydrodynamics and the reduced Hall magnetohydrodynamic equations

    International Nuclear Information System (INIS)

    Martin, L. N.; Dmitruk, P.; Gomez, D. O.

    2010-01-01

    In this work we numerically test a model of Hall magnetohydrodynamics in the presence of a strong mean magnetic field: the reduced Hall magnetohydrodynamic model (RHMHD) derived by [Gomez et al., Phys. Plasmas 15, 102303 (2008)] with the addition of weak compressible effects. The main advantage of this model lies in the reduction of computational cost. Nevertheless, up until now the degree of agreement with the original Hall MHD system and the range of validity in a regime of turbulence were not established. In this work direct numerical simulations of three-dimensional Hall MHD turbulence in the presence of a strong mean magnetic field are compared with simulations of the weak compressible RHMHD model. The results show that the degree of agreement is very high (when the different assumptions of RHMHD, such as spectral anisotropy, are satisfied). Nevertheless, when the initial conditions are isotropic but the mean magnetic field is maintained strong, the results differ at the beginning but asymptotically reach a good agreement at relatively short times. We also found evidence that the compressibility still plays a role in the dynamics of these systems, and the weak compressible RHMHD model is able to capture these effects. In conclusion the weak compressible RHMHD model is a valid approximation of the Hall MHD turbulence in the relevant physical context.

  11. Gallstone ileus resulting in strong intestinal obstruction

    Directory of Open Access Journals (Sweden)

    Israel Szajnbok

    Full Text Available Mechanic intestinal obstruction, caused by the passage of biliary calculus from vesicle to intestine, through fistulization, although not frequent, deserve study due to the morbi-mortality rates. Incidence in elder people explains the association with chronic degenerative diseases, increasing complexity in terms of therapy decision. Literature discusses the need and opportunity for the one or two-phase surgical attack of the cholecystenteric fistule, in front of the resolution on the obstructive urgency and makes reference to Gallstone Ileus as an exception for strong intestinal obstruction. The more frequent intestinal obstruction observed is when it occurs a Gallstone Ileus impacting in terms of ileocecal valve. The authors submit a Gallstone Ileus manifestation as causing strong intestinal obstruction, discussing aspects regarding diagnostic and treatment.

  12. Strong Bulk-Edge Coupling in the Compressible Half-Filled Quantum Hall State

    International Nuclear Information System (INIS)

    Milovanovic, M.V.; Shimshoni, E.

    1999-01-01

    We studied analytically static correlators in the compressible half-filled quantum Hall state, which characterize the nature of charged excitations in the bulk and on the edge of the system. We employ a modified version of the plasma analogy - namely, a mapping to a classical two-dimensional system of interacting particles - similarly to what has been done in studies of the incompressible (Laughlin) states. However, the 'fake plasma' corresponding to the half-filled state is found to have anomalously weak screening properties. As a consequence, the correlations along the edge do not decay algebraically as in the incompressible case, thus indicating the breakdown of Wen's edge theory. On the other hand, the bulk correlator (which parallels the Girvin-MacDonald algebraic off-diagonal long range order) decays algebraically in a similar way as in the incompressible states, signifying the presence of some kind of bosonic order even in the compressible state. The above results suggest that due to the strong coupling between charged modes on the edge and the neutral Fermions (dipoles) in the bulk, the (attractive) correlation hole is not well defined on the edge. Hence, the system there can be modeled as a free Fermi gas of electrons (with an appropriate boundary condition). A possible experimental indication of a strong bulk-edge coupling at half-filling has been indeed observed in non-local resistance measurements [1]. We also suggest, that while our results contradict the validity of an effective one-dimensional description of the edge excitations on the static level, the dynamics may decouple the edge and bulk so as to recover the Laughlin-like behavior apparent in the experiment of Grayson et al

  13. Band gap opening in strongly compressed diamond observed by x-ray energy loss spectroscopy

    International Nuclear Information System (INIS)

    Gamboa, E. J.; Fletcher, L. B.; Lee, H. J.; MacDonald, M. J.; Zastrau, U.; Gauthier, M.; Gericke, D. O.; Vorberger, J.; Granados, E.; Hastings, J. B.; Glenzer, S. H.

    2016-01-01

    The extraordinary mechanical and optical properties of diamond are the basis of numerous technical applications and make diamond anvil cells a premier device to explore the high-pressure behavior of materials. However, at applied pressures above a few hundred GPa, optical probing through the anvils becomes difficult because of the pressure-induced changes of the transmission and the excitation of a strong optical emission. Such features have been interpreted as the onset of a closure of the optical gap in diamond, and can significantly impair spectroscopy of the material inside the cell. In contrast, a comparable widening has been predicted for purely hydrostatic compressions, forming a basis for the presumed pressure stiffening of diamond and resilience to the eventual phase change to BC8. We here present the first experimental evidence of this effect at geo-planetary pressures, exceeding the highest ever reported hydrostatic compression of diamond by more than 200 GPa and any other measurement of the band gap by more than 350 GPa. We here apply laser driven-ablation to create a dynamic, high pressure state in a thin, synthetic diamond foil together with frequency-resolved x-ray scattering as a probe. The frequency shift of the inelastically scattered x-rays encodes the optical properties and, thus, the behavior of the band gap in the sample. Using the ultra-bright x-ray beam from the Linac Coherent Light Source (LCLS), we observe an increasing direct band gap in diamond up to a pressure of 370 GPa. This finding points to the enormous strains in the anvils and the impurities in natural Type Ia diamonds as the source of the observed closure of the optical window. Our results demonstrate that diamond remains an insulating solid to pressures approaching its limit strength.

  14. Band gap opening in strongly compressed diamond observed by x-ray energy loss spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gamboa, E. J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Fletcher, L. B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Lee, H. J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); MacDonald, M. J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Univ. of Michigan, Ann Arbor, MI (United States); Zastrau, U. [High-Energy Density Science Group, Hamburg (Germany); Gauthier, M. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Gericke, D. O. [Univ. of Warwick (United Kingdom); Vorberger, J. [Helmholtz Association of German Research Centres, Dresden (Germany); Granados, E. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Hastings, J. B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Glenzer, S. H. [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-01-25

    The extraordinary mechanical and optical properties of diamond are the basis of numerous technical applications and make diamond anvil cells a premier device to explore the high-pressure behavior of materials. However, at applied pressures above a few hundred GPa, optical probing through the anvils becomes difficult because of the pressure-induced changes of the transmission and the excitation of a strong optical emission. Such features have been interpreted as the onset of a closure of the optical gap in diamond, and can significantly impair spectroscopy of the material inside the cell. In contrast, a comparable widening has been predicted for purely hydrostatic compressions, forming a basis for the presumed pressure stiffening of diamond and resilience to the eventual phase change to BC8. We here present the first experimental evidence of this effect at geo-planetary pressures, exceeding the highest ever reported hydrostatic compression of diamond by more than 200 GPa and any other measurement of the band gap by more than 350 GPa. We here apply laser driven-ablation to create a dynamic, high pressure state in a thin, synthetic diamond foil together with frequency-resolved x-ray scattering as a probe. The frequency shift of the inelastically scattered x-rays encodes the optical properties and, thus, the behavior of the band gap in the sample. Using the ultra-bright x-ray beam from the Linac Coherent Light Source (LCLS), we observe an increasing direct band gap in diamond up to a pressure of 370 GPa. This finding points to the enormous strains in the anvils and the impurities in natural Type Ia diamonds as the source of the observed closure of the optical window. Our results demonstrate that diamond remains an insulating solid to pressures approaching its limit strength.

  15. Local strong solutions to the stochastic compressible Navier-Stokes system

    Czech Academy of Sciences Publication Activity Database

    Breit, D.; Feireisl, Eduard; Hofmanová, M.

    2018-01-01

    Roč. 43, č. 2 (2018), s. 313-345 ISSN 0360-5302 EU Projects: European Commission(XE) 320078 - MATHEF Institutional support: RVO:67985840 Keywords : compressible fluids * local strong solution s * Navier-Stokes system Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 1.608, year: 2016 https://www.tandfonline.com/doi/full/10.1080/03605302.2018.1442476

  16. Local strong solutions to the stochastic compressible Navier-Stokes system

    Czech Academy of Sciences Publication Activity Database

    Breit, D.; Feireisl, Eduard; Hofmanová, M.

    2018-01-01

    Roč. 43, č. 2 (2018), s. 313-345 ISSN 0360-5302 EU Projects: European Commission(XE) 320078 - MATHEF Institutional support: RVO:67985840 Keywords : compressible fluids * local strong solutions * Navier-Stokes system Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 1.608, year: 2016 https://www.tandfonline.com/doi/full/10.1080/03605302.2018.1442476

  17. Issues with Strong Compression of Plasma Target by Stabilized Imploding Liner

    Science.gov (United States)

    Turchi, Peter; Frese, Sherry; Frese, Michael

    2017-10-01

    Strong compression (10:1 in radius) of an FRC by imploding liquid metal liners, stabilized against Rayleigh-Taylor modes, using different scalings for loss based on Bohm vs 100X classical diffusion rates, predict useful compressions with implosion times half the initial energy lifetime. The elongation (length-to-diameter ratio) near peak compression needed to satisfy empirical stability criterion and also retain alpha-particles is about ten. The present paper extends these considerations to issues of the initial FRC, including stability conditions (S*/E) and allowable angular speeds. Furthermore, efficient recovery of the implosion energy and alpha-particle work, in order to reduce the necessary nuclear gain for an economical power reactor, is seen as an important element of the stabilized liner implosion concept for fusion. We describe recent progress in design and construction of the high energy-density prototype of a Stabilized Liner Compressor (SLC) leading to repetitive laboratory experiments to develop the plasma target. Supported by ARPA-E ALPHA Program.

  18. RESULTS OF COMPRESSION TESTING ON PSEUDO-COHESIVE SOIL

    Directory of Open Access Journals (Sweden)

    Ofrikhter Vadim Grigor’evich

    2015-09-01

    Full Text Available Natural non-treated sand reinforced with randomly oriented short polypropylene fibers of 12 mm in length was tested to determine creep characteristics. This study is a part of the research aimed at encouraging fibrosand (FRS application in subsoils, embankments and retaining wall constructions. Fiber content was accounted for 0.93 %. Twin specimens were put to creep tests (1-D compression using the two curve method. The test results were analyzed and checked with the use of ageing, hardening and hereditary creep theories. On the basis of approximation of the test results the creep deformation equation at constant stress for tested fibrosand was obtained. The assessment of fibrosand secondary compression was carried out by the FORE method. As a result, the value of the void ratio by the end of the secondary compression had been eu=0.7041. For determination of the beginning of the secondary compression the rate equation was superimposed on the empirical curve. The point of the graph divergence is the beginning of the secondary compression process. The secondary compression had begun by the time moment being equal to 9360 min. The void ratio by the beginning of the secondary compression had amounted to 0.70574. Fibrosand is a specific type of improved soil relating to so-called pseudo-cohesive soil. This type of soil is characterized by cohesion like cohesive soils, but, at the same time, by the filtration coefficient of about 1 m per day like non-cohesive soils. Pseudo-cohesive soil testing helps to understand the distinctive features of the stress-strain state of this kind of materials. Municipal solid waste also relates to them.

  19. Strong compression of a magnetic field with a laser-accelerated foil.

    Science.gov (United States)

    Yoneda, Hitoki; Namiki, Tomonori; Nishida, Akinori; Kodama, Ryosuke; Sakawa, Youichi; Kuramitsu, Yasuhiro; Morita, Taichi; Nishio, Kento; Ide, Takao

    2012-09-21

    We demonstrate the generation of high magnetic fields for condensed matter research using a high-power laser system. A cavity in which a seed magnetic field is applied is compressed by a kJ ns laser pulse. The time history of the compressed magnetic field is monitored by observing the Faraday effect rotation of polarization of a probe pulse in a glass fiber. To maintain a low-temperature condition in the final high-field region, we put a high-resistance foil around the final compression area. If we assume the length of the compression region is equal to the laser spot size, a magnetic field of more than 800 T is observed by Faraday rotation. Because of the large mass of the compression foil, this high magnetic field is sustained during almost 2 ns. During compression, a rarefaction wave from the backside of the accelerated foil and expanding material from the inner protection foil affect the magnetic field compression history, but the final compressed magnetic field strength agrees with the ratio between the initial sample area and the compressed cavity area.

  20. New results on strong-interaction effects in antiprotonic hydrogen

    CERN Document Server

    Gotta, D; Augsburger, M A; Borchert, G L; Castelli, C M; Chatellard, D; El-Khoury, P; Egger, J P; Gorke, H; Hauser, P R; Indelicato, P J; Kirch, K; Lenz, S; Nelms, N; Rashid, K; Schult, O W B; Siems, T; Simons, L M

    1999-01-01

    Lyman and Balmer transitions of antiprotonic hydrogen and deuterium have been measured at the low-energy antiproton ring LEAR at CERN in order to determine the strong interaction effects. The X-rays were detected using charge-coupled devices (CCDs) and a reflection type crystal spectrometer. The results of the measurements support the meson-exchange models describing the medium and long range part of the nucleon-antinucleon interaction. (33 refs).

  1. New results on strong-interaction effects in antiprotonic hydrogen

    International Nuclear Information System (INIS)

    Anagnostopoulos, D. F.; Augsburger, M.; Borchert, G.; Castelli, C.; Chatellard, D.; El-Khoury, P.; Egger, J.-P.; Gorke, H.; Gotta, D.; Hauser, P.; Indelicato, P.; Kirch, K.; Lenz, S.; Nelms, N.; Rashid, K.; Schult, O. W. B.; Siems, Th.; Simons, L. M.

    1999-01-01

    Lyman and Balmer transitions of antiprotonic hydrogen and deuterium have been measured at the Low-Energy Antiproton Ring LEAR at CERN in order to determine the strong interaction effects. The X-rays were detected using Charge-Coupled Devices (CCDs) and a reflection type crystal spectrometer. The results of the measurements support the meson-exchange models describing the medium and long range part of the nucleon-antinucleon interaction

  2. Compression of TW class laser pulses in a planar hollow waveguide for applications in strong-field physics

    Science.gov (United States)

    Jarnac, Amélie; Brizuela, Fernando; Heyl, Christoph M.; Rudawski, Piotr; Campi, Filippo; Kim, Byunghoon; Rading, Linnea; Johnsson, Per; Mysyrowicz, André; L'Huillier, Anne; Houard, Aurélien; Arnold, Cord L.

    2014-12-01

    We demonstrate pulse post-compression of a TW class chirped pulse amplification laser employing a gas-filled planar hollow waveguide. A waveguide throughput of 80% is achieved for 50 mJ input pulse energy. Good focusability is found and after compression with chirped mirrors a pulse duration of sub-15 fs is measured in the beam center. Whereas a total energy efficiency of ≈70% should be achievable, our post-compressor currently delivers 20 mJ output pulse energy (≈40% efficiency), mostly limited by apertures of chirped mirrors and vacuum windows. The viability of the planar hollow waveguide compression scheme for applications in strong-field physics is demonstrated by generating high-order harmonics in a pulsed Ar gas cell. Contribution to the Topical Issue "X-ray Generation from Ultrafast Lasers", edited by Germán J. de Valcárcel, Luis Roso and Amelle Zaïr.

  3. Strongly compressed Bi (111) bilayer films on Bi{sub 2}Se{sub 3} studied by scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, K. F.; Yang, Fang; Song, Y. R. [Key Laboratory of Artificial Structures and Quantum Control (Ministry of Education), Department of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240 (China); Liu, Canhua; Qian, Dong; Gao, C. L.; Jia, Jin-Feng [Key Laboratory of Artificial Structures and Quantum Control (Ministry of Education), Department of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240 (China); Collaborative Innovation Center of Advanced Microstructures, Nanjing 210093 (China)

    2015-09-21

    Ultra-thin Bi films show exotic electronic structure and novel quantum effects, especially the widely studied Bi (111) film. Using reflection high-energy electron diffraction and scanning tunneling microscopy, we studied the structure and morphology evolution of Bi (111) thin films grown on Bi{sub 2}Se{sub 3}. A strongly compressed, but quickly released in-plane lattice of Bi (111) is found in the first three bilayers. The first bilayer of Bi shows a fractal growth mode with flat surface, while the second and third bilayer show a periodic buckling due to the strong compression of the in-plane lattice. The lattice slowly changes to its bulk value with further deposition of Bi.

  4. Compressibility effects on a shear flow in strongly coupled dusty plasma. I. A study using computational fluid dynamics

    Science.gov (United States)

    Gupta, Akanksha; Ganesh, Rajaraman

    2018-01-01

    We study compressibility effects on the two-dimensional strongly coupled dusty plasma by means of computational fluid dynamics (CFD) with the Kolmogorov flow as an initial shear flow profile. Nonlinear compressible vortex flow dynamics and other linear and nonlinear properties of such flow in the presence of variable density, pressure, and electrostatic potential are addressed using a generalised compressible hydrodynamic model. The stabilizing effect of compressibility on the unstable shear flows in the presence of strong correlation ( τm>0 ) is presented. Increasing the Mach number relatively reduces the growth-rate of perturbation. On the other hand, strong correlation makes the medium to be more unstable and increases the growth rate. Using an eigen value solver, various linear properties of compressible Kolmogorov flow have been investigated for a range of variable parameters, for example, Mach number, Reynolds number, and viscoelastic coefficient (τm). Compressible Kolmogorov flow becomes unstable above a critical value of the Reynolds number (Rc), and below Rc, the shear flow is found to be neutrally stable. In this study, it is found that the viscoelasticity reduces the value of Rc. For our choice of parameters, at τm=τmc , the compressible Kolmogorov flow becomes unconditionally unstable and no Rc exists for values of τm higher than τmc . To address the nonlinear properties, for example, mode-mode interaction due to the presence of nonlinearity in the fluid, vortex formation, etc., a massively parallelized Advanced Generalized SPECTral Code (AG-Spect) has been developed. AG-Spect, a newly developed code, is an efficient tool to solve any set of nonlinear fluid dynamic equations. A good agreement in linear growth rates obtained from the eigen value solver and time dependent simulation (AG-Spect) is found. In our CFD study, the suppression of instability, elongated vortex structures, pattern formation, nonlinear saturation, and visco

  5. Relative entropies, suitable weak solutions, and weak-strong uniqueness for the compressible Navier–Stokes system

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard; Jin, B.J.; Novotný, A.

    2012-01-01

    Roč. 14, č. 4 (2012), s. 717-730 ISSN 1422-6928 R&D Projects: GA ČR GA201/09/0917 Institutional research plan: CEZ:AV0Z10190503 Keywords : suitable weak solution * weak-strong uniqueness * compressible Navier-Stokes system Subject RIV: BA - General Mathematics Impact factor: 1.415, year: 2012 http://link.springer.com/article/10.1007%2Fs00021-011-0091-9

  6. A steady Navier-Stokes model for compressible fluid with partially strong solutions

    Czech Academy of Sciences Publication Activity Database

    Muzereau, O.; Neustupa, Jiří; Penel, P.

    2010-01-01

    Roč. 348, 11-12 (2010), s. 619-624 ISSN 1631-073X R&D Projects: GA ČR GA201/08/0012 Institutional research plan: CEZ:AV0Z10190503 Keywords : Navier-Stokes equations * Compressible fluids * Weak solution Subject RIV: BA - General Mathematics Impact factor: 0.399, year: 2010 http://www.sciencedirect.com/science/article/pii/S1631073X10001160

  7. Robustness of strong solutions to the compressible Navier-Stokes system

    Czech Academy of Sciences Publication Activity Database

    Bella, P.; Feireisl, Eduard; Jin, B.J.; Novotný, A.

    2015-01-01

    Roč. 362, 1-2 (2015), s. 281-303 ISSN 0025-5831 EU Projects: European Commission(XE) 320078 - MATHEF Institutional support: RVO:67985840 Keywords : compressible Navier-Stokes system * smooth solution * stability Subject RIV: BA - General Mathematics Impact factor: 1.366, year: 2015 http://link.springer.com/article/10.1007%2Fs00208-014-1119-2

  8. Exact result in strong wave turbulence of thin elastic plates

    Science.gov (United States)

    Düring, Gustavo; Krstulovic, Giorgio

    2018-02-01

    An exact result concerning the energy transfers between nonlinear waves of a thin elastic plate is derived. Following Kolmogorov's original ideas in hydrodynamical turbulence, but applied to the Föppl-von Kármán equation for thin plates, the corresponding Kármán-Howarth-Monin relation and an equivalent of the 4/5 -Kolmogorov's law is derived. A third-order structure function involving increments of the amplitude, velocity, and the Airy stress function of a plate, is proven to be equal to -ɛ ℓ , where ℓ is a length scale in the inertial range at which the increments are evaluated and ɛ the energy dissipation rate. Numerical data confirm this law. In addition, a useful definition of the energy fluxes in Fourier space is introduced and proven numerically to be flat in the inertial range. The exact results derived in this Rapid Communication are valid for both weak and strong wave turbulence. They could be used as a theoretical benchmark of new wave-turbulence theories and to develop further analogies with hydrodynamical turbulence.

  9. Super-tough, ultra-stretchable and strongly compressive hydrogels with core-shell latex particles inducing efficient aggregation of hydrophobic chains.

    Science.gov (United States)

    Ren, Xiuyan; Huang, Chang; Duan, Lijie; Liu, Baijun; Bu, Lvjun; Guan, Shuang; Hou, Jiliang; Zhang, Huixuan; Gao, Guanghui

    2017-05-14

    Toughness, strechability and compressibility for hydrogels were ordinarily balanced for their use as mechanically responsive materials. For example, macromolecular microsphere composite hydrogels with chemical crosslinking exhibited excellent compression strength and strechability, but poor tensile stress. Here, a novel strategy for the preparation of a super-tough, ultra-stretchable and strongly compressive hydrogel was proposed by introducing core-shell latex particles (LPs) as crosslinking centers for inducing efficient aggregation of hydrophobic chains. The core-shell LPs always maintained a spherical shape due to the presence of a hard core even by an external force and the soft shell could interact with hydrophobic chains due to hydrophobic interactions. As a result, the hydrogels reinforced by core-shell LPs exhibited not only a high tensile strength of 1.8 MPa and dramatic elongation of over 20 times, but also an excellent compressive performance of 13.5 MPa at a strain of 90%. The Mullins effect was verified for the validity of core-shell LP-reinforced hydrogels by inducing aggregation of hydrophobic chains. The novel strategy strives to provide a better avenue for designing and developing a new generation of hydrophobic association tough hydrogels with excellent mechanical properties.

  10. Polarization and Strong Infra-Red Activity in Compressed Solid Hydrogen

    OpenAIRE

    Souza, Ivo; Martin, Richard M.

    1998-01-01

    Under a pressure of ~150 GPa solid molecular hydrogen undergoes a phase transition accompanied by a dramatic rise in infra-red absorption in the vibron frequency range. We use the Berry's phase approach to calculate the electric polarization in several candidate structures finding large, anisotropic dynamic charges and strongly IR-active vibron modes. The polarization is shown to be greatly affected by the overlap between the molecules in the crystal, so that the commonly used Clausius-Mossot...

  11. Iliopsoas bursitis with compression of the common femoral vein resulting in acute lower leg edema

    International Nuclear Information System (INIS)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Lee, Sang Yong; Jeong, Yeon Jun

    2006-01-01

    The clinical manifestations related to iliopsoas bursitis can vary due to compression of the adjacent structure such as the common femoral vein, nerve and bladder. We report here on a rare case of iliopsoas bursitis with compression of the common femoral vein that resulted in acute lower leg edema

  12. Iliopsoas bursitis with compression of the common femoral vein resulting in acute lower leg edema

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Lee, Sang Yong; Jeong, Yeon Jun [Chonbuk National University Medical School, Chonju (Korea, Republic of)

    2006-08-15

    The clinical manifestations related to iliopsoas bursitis can vary due to compression of the adjacent structure such as the common femoral vein, nerve and bladder. We report here on a rare case of iliopsoas bursitis with compression of the common femoral vein that resulted in acute lower leg edema.

  13. Shock compression of strongly correlated oxides: A liquid-regime equation of state for cerium(IV) oxide

    Science.gov (United States)

    Weck, Philippe F.; Cochrane, Kyle R.; Root, Seth; Lane, J. Matthew D.; Shulenburger, Luke; Carpenter, John H.; Sjostrom, Travis; Mattsson, Thomas R.; Vogler, Tracy J.

    2018-03-01

    The shock Hugoniot for full-density and porous CeO2 was investigated in the liquid regime using ab initio molecular dynamics (AIMD) simulations with Erpenbeck's approach based on the Rankine-Hugoniot jump conditions. The phase space was sampled by carrying out NVT simulations for isotherms between 6000 and 100 000 K and densities ranging from ρ =2.5 to 20 g /cm3 . The impact of on-site Coulomb interaction corrections +U on the equation of state (EOS) obtained from AIMD simulations was assessed by direct comparison with results from standard density functional theory simulations. Classical molecular dynamics (CMD) simulations were also performed to model atomic-scale shock compression of larger porous CeO2 models. Results from AIMD and CMD compression simulations compare favorably with Z-machine shock data to 525 GPa and gas-gun data to 109 GPa for porous CeO2 samples. Using results from AIMD simulations, an accurate liquid-regime Mie-Grüneisen EOS was built for CeO2. In addition, a revised multiphase SESAME-type EOS was constrained using AIMD results and experimental data generated in this work. This study demonstrates the necessity of acquiring data in the porous regime to increase the reliability of existing analytical EOS models.

  14. Compressible Kolmogorov flow in strongly coupled dusty plasma using molecular dynamics and computational fluid dynamics. II. A comparative study

    Science.gov (United States)

    Gupta, Akanksha; Ganesh, Rajaraman; Joy, Ashwin

    2018-01-01

    In this paper, we perform comparative studies of compressible Kolmogorov flow in the two-dimensional strongly coupled dusty plasma by means of atomistic or molecular dynamics (MD) and continuum or computational fluid dynamics (CFD) methods. Recently, using MD simulation, generation of molecular shear heat at the atomistic level is shown to reduce the average coupling strength of the system and destruct the vortical structures. To suppress the molecular heat, a novel method of a thermostat, namely, the configurational thermostat is introduced by which the microscale heat generated by the shear flow has shown to be thermostatted out efficiently without compromising the large scale vortex dynamics. While using a configurational thermostat, it has been found that the growth rate obtained from both the studies is the same with the marginal difference. To make the comparison with the continuum fluid model, we perform the same study using the generalised hydrodynamic model, wherein molecular shear heating phenomena is completely absent, however, viscous dissipation is there at the macroscale level. For this purpose, an Advanced Generalised SPECTral Code has been developed to study the linear and nonlinear aspects of the Kolmogorov flow in the incompressible and compressible limit for viscoelastic fluids. All the phenomenological parameters used in CFD simulations have been calculated from MD simulations. Code is benchmarked against the eigen value solver in the linear regime. Linear growth-rates calculated from the phenomenological fluid model is found to be close to that obtained from MD simulation for the same set of input parameters. The transition from laminar to turbulent flow has been found at a critical value of Reynolds number Rc in both the macroscopic (CFD) and microscopic (MD) simulation. Rc in MD is smaller than the one obtained by CFD simulation. In the nonlinear regime of CFD, the mode becomes unstable and vortex formation happens earlier than in MD. The

  15. Strong morphological and crystallographic texture and resulting yield strength anisotropy in selective laser melted tantalum

    International Nuclear Information System (INIS)

    Thijs, Lore; Montero Sistiaga, Maria Luz; Wauthle, Ruben; Xie, Qingge; Kruth, Jean-Pierre; Van Humbeeck, Jan

    2013-01-01

    Selective laser melting (SLM) makes use of a high energy density laser beam to melt successive layers of metallic powders in order to create functional parts. The energy density of the laser is high enough to melt refractory metals like Ta and produce mechanically sound parts. Furthermore, the localized heat input causes a strong directional cooling and solidification. Epitaxial growth due to partial remelting of the previous layer, competitive growth mechanism and a specific global direction of heat flow during SLM of Ta result in the formation of long columnar grains with a 〈1 1 1〉 preferential crystal orientation along the building direction. The microstructure was visualized using both optical and scanning electron microscopy equipped with electron backscattered diffraction and the global crystallographic texture was measured using X-ray diffraction. The thermal profile around the melt pool was modeled using a pragmatic model for SLM. Furthermore, rotation of the scanning direction between different layers was seen to promote the competitive growth. As a result, the texture strength increased to as large as 4.7 for rotating the scanning direction 90° every layer. By comparison of the yield strength measured by compression tests in different orientations and the averaged Taylor factor calculated using the viscoplastic self-consistent model, it was found that both the morphological and crystallographic texture observed in SLM Ta contribute to yield strength anisotropy

  16. Transport properties of LiF under strong compression: modeling using advanced electronic structure methods and classical molecular dynamics

    Science.gov (United States)

    Mattsson, Thomas R.; Jones, Reese; Ward, Donald; Spataru, Catalin; Shulenburger, Luke; Benedict, Lorin X.

    2015-06-01

    Window materials are ubiquitous in shock physics and with high energy density drivers capable of reaching multi-Mbar pressures the use of LiF is increasing. Velocimetry and temperature measurements of a sample through a window are both influenced by the assumed index of refraction and thermal conductivity, respectively. We report on calculations of index of refraction using the many-body theory GW and thermal ionic conductivity using linear response theory and model potentials. The results are expected to increase the accuracy of a broad range of high-pressure shock- and ramp compression experiments. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Company, for the U.S. Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL85000.

  17. The investigation on compressed air quality analysis results of nuclear power plants

    International Nuclear Information System (INIS)

    Sung, K. B.; Kim, H. K.; Kim, W. S.

    2000-01-01

    The compressed air system of nuclear power plants provides pneumatic power for both operation and control of various plant equipment, tools, and instrumentation. Included in the air supply systems are the compressors, coolers, moisture separators, dryers, filters and air receiver tanks that make up the major items of equipment. The service air system provides oil-free compressed air for general plant and maintenance use and the instrument air system provides dry, oil-free, compressed air for both nonessential and essential components and instruments. NRC recommended the periodic checks on GL88-14 'Instrument air supply system problems affecting safety-related equipment'. To ensure that the quality of the instrument air is equivalent to or exceeds the requirement s of ISA-S7.3(1975), air samples are taken at every refueling outage and analyzed for moisture, oil and particulate content. The over all results are satisfied the requirements of ISA-S7.3

  18. Remarks on the Liouville type results for the compressible Navier–Stokes equations in RN

    International Nuclear Information System (INIS)

    Chae, Dongho

    2012-01-01

    In this paper, we prove Liouville type result for the stationary solutions to the compressible Navier–Stokes equations (NS) and the compressible Navier–Stokes–Poisson (NSP) equations and in R N , N ≥ 2. Assuming suitable integrability and the uniform boundedness conditions for the solutions we are led to the conclusion that v = 0. In the case of (NS) we deduce that the similar integrability conditions imply v = 0 and ρ = constant on R N . This shows that if we impose the the non-vacuum boundary condition at spatial infinity for (NS), v → 0 and ρ → ρ ∞ > 0, then v = 0, ρ = ρ ∞ are the solutions

  19. Treatment Results Of Diaphyseal Forearm Fractures With Dynamique Compression Plate A Retrospective study of 156 Cases.

    Directory of Open Access Journals (Sweden)

    Hassan BOUSSAKRI

    2015-12-01

    Full Text Available This retrospective study addresses a series of 156 cases of forearm fractures. These 156 cases were managed in the trauma-orthopedic department (B4 of Fez University Hospital, Morocco, from May 2008 till January 2013. The purpose of this study is to analyze epidemiological and clinical factors of diaphyseal forearm fractures and the results of their treatment with dynamic compression plate (DCP, as well as the complications and therapeutic errors of this surgical technique. The frequency of hospitalization in the trauma-orthopedic department was 3,96%. Ages ranged between 16 and 83, the average age was 32. 132 patients were male (85%. 90% were managed at the day of trauma. Traffic accidents were the most frequent cause in 52% patients. The fracture was in the left forearm in 65% of patients. 53% of fracture lines were in the middle third of the forearm. 38 fractures were open, and 30 were admitted for polytrauma. Osteosynthesis was performed with dynamic compression plate for all patients. In comparison with the literature, our series shows the predominance of young male patients, with traffic accidents being the cause. Osteosynthesis with dynamic compression plate remains the treatment of choice that provides satisfactory results if the accuracy in this technique was respected.

  20. Estimation of compressive strength based on Pull-Out bond test results for on-site concrete quality control

    Directory of Open Access Journals (Sweden)

    M. S. Lorrain

    Full Text Available Quality control of structural concrete has been conducted for several decades based mainly on the results of axial compression tests. This kind of test, although widely used, is not exempt from errors and has some considerable drawbacks that may affect its reliability, such as the need for appropriate and careful specimen conditioning and adoption of adequate capping techniques. For these reasons, it would be useful to have complementary or alternative ways to check compressive strength, in order to improve concrete quality control. The use of a bond test to monitor concrete strength is being proposed by an international group of researchers from France, Tunisia and Brazil as a potential means to this end. Given the fact that the link between bond resistance and concrete strength is already well established, this type of test seems to be a viable alternative to traditional methods. Nonetheless, to check if the underlying principle is sound when used in different circumstances, the group has been gathering data from several studies conducted by different researchers in various countries, with distinct concretes and rebar types. An analysis of the data collected shows that there is a clear and strong correlation between bond resistance and compressive strength, no matter the influence of other variables. This result validates the basic idea of using an Appropriate Pull-Out (APULOT bond test to assess concrete strength. If the general principle is valid for random data obtained from different studies, the definition of a clear and appropriate test will probably lead to the reduction of experimental noise and increase the precision of the strength estimates obtained using this method.

  1. Strong Lensing Science Results from the Hyper Suprime-Cam Survey

    Science.gov (United States)

    Wong, Kenneth; HSC SSP Strong Lens Working Group

    2018-01-01

    Strong gravitational lenses are valuable objects for studying galaxy structure and cosmology. Lensing is a unique probe of the dark matter structure of galaxies, groups, and clusters, as well as an independent tool for constraining cosmological parameters. Lensing also magnifies the background source population, allowing for detailed studies of their properties at high resolution. However, strong lenses are rare and difficult to find, requiring deep wide-area high-resolution imaging surveys. With data from the ongoing Hyper Suprime-Cam (HSC) Subaru Strategic Program, we have discovered over 100 new strong lenses at the galaxy and group scale to expand the sample of lensing systems, particularly at redshifts z > 0.5, where there have previously been relatively few known lenses. We present a summary of the latest strong lensing science results from the HSC survey data taken through the S17A semester.

  2. arXiv Recent results from the strong interactions program of NA61/SHINE

    CERN Document Server

    Pulawski, Szymon

    2017-01-01

    The NA61/SHINE experiment studies hadron production in hadron+hadron, hadron+nucleus and nucleus+nucleus collisions. The strong interactions program has two main purposes: study the properties of the onset of deconfinement and search for the signatures of the critical point of strongly interacting matter. This aim is pursued by performing a two-dimensional scan of the phase diagram by varying the energy/momentum (13A-158A GeV/c) and the system size (p+p, Be+Be, Ar+Sc, Xe+La) of the collisions. This publication reviews recent results from p+p, Be+Be and Ar+Sc interactions. Measured particle spectra are discussed and compared to NA49 results from Pb+Pb collisions. The results illustrate the progress towards scanning the phase diagram of strongly interacting matter.

  3. The creation of strongly coupled plasmas using an intense heavy ion beam: low-entropy compression of hydrogen and the problem of hydrogen metallization

    Energy Technology Data Exchange (ETDEWEB)

    Tahir, N A [Institut fuer Theoretische Physik, Universitaet Frankfurt, Postfach 11 19 32, 60054 Frankfurt (Germany); Piriz, A R [ETSI Industriales, Universidad de Castilla-La Mancha, 13071 Ciudad Real (Spain); Shutov, A [Institute for Problems in Chemical Physics Research, Chernogolovka, Russia (Russian Federation); Varentsov, D [Institut fuer Kernphysik, Technische Universitaet Darmstadt, Schlossgarten Str. 9, 64289 Darmstadt (Germany); Udrea, S [Institut fuer Kernphysik, Technische Universitaet Darmstadt, Schlossgarten Str. 9, 64289 Darmstadt (Germany); Hoffmann, D H H [Institut fuer Kernphysik, Technische Universitaet Darmstadt, Schlossgarten Str. 9, 64289 Darmstadt (Germany); Juranek, H [Fachbereich Physik, Universitaet Rostock, 18051 Rostock (Germany); Redmer, R [Fachbereich Physik, Universitaet Rostock, 18051 Rostock (Germany); Portugues, R F [ETSI Industriales, Universidad de Castilla-La Mancha, 13071 Ciudad Real (Spain); Lomonosov, I [Institute for Problems in Chemical Physics Research, Chernogolovka, Russia (Russian Federation); Fortov, V E [Institute for Problems in Chemical Physics Research, Chernogolovka, Russia (Russian Federation)

    2003-06-06

    Intense heavy ion beams deposit energy very efficiently over extended volumes of solid density targets, thereby creating large samples of strongly coupled plasmas. Intense beams of energetic heavy ions are therefore an ideal tool to research this interesting field. It is also possible to design experiments using special beam-target geometries to achieve low-entropy compression of samples of matter. This type of experiments is of particular interest for studying the problem of hydrogen metallization. In this paper we present a design study of such a proposed experiment that will be carried out at the future heavy ion synchrotron facility SIS100, at the Gesellschaft fuer Schwerionenforschung, Darmstadt. This study has been done using a two-dimensional hydrodynamic computer code. The target consists of a solid hydrogen cylinder that is enclosed in a thick shell of lead whose one face is irradiated with an ion beam which has an annular (ring shaped) focal spot. The beam intensity and other parameters are considered to be the same as expected at the future SIS100 facility. The simulations show that due to multiple shock reflection between the cylinder axis and the lead-hydrogen boundary, one can achieve up to 20 times solid density in hydrogen while keeping the temperature as low as a few thousand K. The corresponding pressure is of the order of 10 Mbar. These values of the physical parameters lie within the range of theoretically predicted values for hydrogen metallization. We have also carried out a parameter study of this problem by varying the target and beam parameters over a wide range. It has been found that the results are very insensitive to such changes in the input parameters.

  4. The propagation of a strong x-ray pulse followed by pulse slowdown and compression, amplified spontaneous emission and lasing without inversion

    Energy Technology Data Exchange (ETDEWEB)

    Sun Yuping; Liu Jicai; Gel' mukhanov, Faris, E-mail: jicai@theochem.kth.s [Department of Theoretical Chemistry, School of Biotechnology, Royal Institute of Technology, S-106 91 Stockholm (Sweden)

    2009-10-28

    We study self-seeded stimulated resonant x-ray Raman scattering and show a 20-fold compression of the strong XFEL pulse propagating through the resonant medium of atomic argon with the frequency (244.3 eV) tuned to the 2p{sub 3/2}-4s resonance. The strong x-ray pulse inverts the medium and produces an extensive ringing tail which widens the power spectrum. Newly created seed field triggers the Stokes channel 3s-2p{sub 3/2} of amplified spontaneous emission. The population inversions are quenched for longer propagation distances where lasing without inversion enhances the Stokes component. The pump pulse also generates weaker Stokes and anti-Stokes fields caused by four-wave mixing. The group velocity is decreased up to 78% of the speed of light in vacuum. (fast track communication)

  5. The propagation of a strong x-ray pulse followed by pulse slowdown and compression, amplified spontaneous emission and lasing without inversion

    International Nuclear Information System (INIS)

    Sun Yuping; Liu Jicai; Gel'mukhanov, Faris

    2009-01-01

    We study self-seeded stimulated resonant x-ray Raman scattering and show a 20-fold compression of the strong XFEL pulse propagating through the resonant medium of atomic argon with the frequency (244.3 eV) tuned to the 2p 3/2 -4s resonance. The strong x-ray pulse inverts the medium and produces an extensive ringing tail which widens the power spectrum. Newly created seed field triggers the Stokes channel 3s-2p 3/2 of amplified spontaneous emission. The population inversions are quenched for longer propagation distances where lasing without inversion enhances the Stokes component. The pump pulse also generates weaker Stokes and anti-Stokes fields caused by four-wave mixing. The group velocity is decreased up to 78% of the speed of light in vacuum. (fast track communication)

  6. Left main bronchus compression as a result of tuberculous lymphnode compression of the right-sided airways with right lung volume loss in children.

    Science.gov (United States)

    Andronikou, S; Van Wyk, M J; Goussard, P; Gie, R P

    2014-03-01

    The superior mediastinal space is confined by the sterno-manubrium anteriorly and the vertebral column posterior. An abnormal relationship between the superior mediastinal structures may result in compression of the left main bronchus. In patients with right-sided pneumonectomy an exaggerated compensatory response may lead to stretching and compression of the remainder of the intra-thoracic airway. Lymphobronchial TB mimics pneumonectomy when it causes compression of the bronchus intermedius, between nodal lymphnode groups with resultant volume loss in the right lung and displacement of the mediastinum to the right. The left main bronchus may be at risk of compression due to rotation and displacement of the major vessels. To report pediatric cases of right-sided lymphobronchial TB with volume loss, demonstrate the use of angle measurements to quantify mediastinal dynamics and support a pathogenetic theory for left main bronchus compression. CT scans in children with TB and right lung volume loss, were compared retrospectively with controls using angle measurements based on descriptions of the aorta-carinal syndrome and the post-pneumonectomy syndrome. The Mann-Whitney U-test was used to compare groups. The "Pulmonary bifurcation angle" between the main pulmonary arteries reached statistical significance (P = 0.025). The "Pulmonary outflow tract rotation" angle (pulmonary trunk with the mid sagittal plane) approached statistical significance (P = 0.078). The left main bronchus ranged from complete obliteration in two patients to 0.7 cm. In 16 of 30 patients the size was reduced to less than 75% of expected. In children with right lung volume loss from TB, the compression of the contralateral bronchus is due to narrowing of the pulmonary artery bifurcation angle as the main trunk rotates towards the midline. This is comparable to the post-pneumonectomy syndrome. © 2012 Wiley Periodicals, Inc.

  7. Propagation of a strong x-ray pulse: Pulse compression, stimulated Raman scattering, amplified spontaneous emission, lasing without inversion, and four-wave mixing

    International Nuclear Information System (INIS)

    Sun Yuping; Wang Chuankui; Liu Jicai; Gel'mukhanov, Faris

    2010-01-01

    We study the compression of strong x-ray pulses from x-ray free-electron lasers (XFELs) propagating through the resonant medium of atomic argon. The simulations are based on the three-level model with the frequency of the incident x-ray pulse tuned in the 2p 3/2 -4s resonance. The pulse propagation is accompanied by the self-seeded stimulated resonant Raman scattering (SRRS). The SRRS starts from two channels of amplified spontaneous emission (ASE), 4s-2p 3/2 and 3s-2p 3/2 , which form the extensive ringing pattern and widen the power spectrum. The produced seed field triggers the Stokes ASE channel 3s-2p 3/2 . The population inversion is quenched for longer propagation distances where the ASE is followed by the lasing without inversion (LWI), which amplifies the Stokes component. Both ASE and LWI reshape the input pulse: The compressed front part of the pulse (up to 100 as) is followed by the long tail of the ringing and beating between the pump and Stokes frequencies. The pump pulse also generates weaker Stokes and anti-Stokes fields caused by four-wave mixing. These four spectral bands have fine structures caused by the dynamical Stark effect. A slowdown of the XFEL pulse up to 78% of the speed of light in vacuum is found because of a large nonlinear refractive index.

  8. Identifying and Characterizing Discrepancies Between Test and Analysis Results of Compression-Loaded Panels

    Science.gov (United States)

    Thornburgh, Robert P.; Hilburger, Mark W.

    2005-01-01

    Results from a study to identify and characterize discrepancies between validation tests and high-fidelity analyses of compression-loaded panels are presented. First, potential sources of the discrepancies in both the experimental method and corresponding high-fidelity analysis models were identified. Then, a series of laboratory tests and numerical simulations were conducted to quantify the discrepancies and develop test and analysis methods to account for the discrepancies. The results indicate that the discrepancies between the validation tests and high-fidelity analyses can be attributed to imperfections in the test fixture and specimen geometry; test-fixture-induced changes in specimen geometry; and test-fixture-induced friction on the loaded edges of the test specimen. The results also show that accurate predictions of the panel response can be obtained when these specimen imperfections and edge conditions are accounted for in the analysis. The errors in the tests and analyses, and the methods used to characterize these errors are presented.

  9. Quantitative Results from Shockless Compression Experiments on Solids to Multi-Megabar Pressure

    Science.gov (United States)

    Davis, Jean-Paul; Brown, Justin; Knudson, Marcus; Lemke, Raymond

    2015-03-01

    Quasi-isentropic, shockless ramp-wave experiments promise accurate equation-of-state (EOS) data in the solid phase at relatively low temperatures and multi-megabar pressures. In this range of pressure, isothermal diamond-anvil techniques have limited pressure accuracy due to reliance on theoretical EOS of calibration standards, thus accurate quasi-isentropic compression data would help immensely in constraining EOS models. Multi-megabar shockless compression experiments using the Z Machine at Sandia as a magnetic drive with stripline targets continue to be performed on a number of solids. New developments will be presented in the design and analysis of these experiments, including topics such as 2-D and magneto-hydrodynamic (MHD) effects and the use of LiF windows. Results will be presented for tantalum and/or gold metals, with comparisons to independently developed EOS. * Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  10. Results from New Multi-Megabar Shockless Compression Experiments at the Z Machine

    Science.gov (United States)

    Davis, Jean-Paul; Brown, Justin; Knudson, Marcus

    2015-06-01

    Quasi-isentropic, shockless ramp-wave experiments promise accurate equation-of-state (EOS) data in the solid phase at relatively low temperatures and multi-megabar pressures. In this range of pressure, isothermal diamond-anvil techniques have limited pressure accuracy due to reliance on theoretical EOS of calibration standards, thus accurate quasi-isentropic compression data would help immensely in constraining EOS models. Multi-megabar shockless compression experiments using the Z Machine at Sandia as a magnetic drive with stripline targets have recently been improved. New developments will be presented in the design and analysis of these experiments, including topics such as 2-D and magneto-hydrodynamic (MHD) effects and the use of LiF windows. Results will be presented for selected metals, with comparisons to independently developed EOS. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL85000.

  11. Lattice Hamiltonian approach to the Schwinger model. Further results from the strong coupling expansion

    International Nuclear Information System (INIS)

    Szyniszewski, Marcin; Manchester Univ.; Cichy, Krzysztof; Poznan Univ.; Kujawa-Cichy, Agnieszka

    2014-10-01

    We employ exact diagonalization with strong coupling expansion to the massless and massive Schwinger model. New results are presented for the ground state energy and scalar mass gap in the massless model, which improve the precision to nearly 10 -9 %. We also investigate the chiral condensate and compare our calculations to previous results available in the literature. Oscillations of the chiral condensate which are present while increasing the expansion order are also studied and are shown to be directly linked to the presence of flux loops in the system.

  12. Experimental Results Obtained with Air Liquide Cold Compression System CERN LHC and SNS Projects

    CERN Document Server

    Delcayre, F; Hamber, F; Hilbert, B; Monneret, E; Toia, J L

    2006-01-01

    Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high‐capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC wil...

  13. Commissioning and operational results of the 12 GeV helium compression system at Jlab

    Energy Technology Data Exchange (ETDEWEB)

    Knudsen, Peter N. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Ganni, Venkatarao [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Dixon, Kelly D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Norton, Robert O. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Creel, Jonathan D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2015-12-01

    The new compressor system at Jefferson Lab (JLab) for the 12 GeV upgrade was commissioned in the spring of 2013 and incorporates many design changes, discussed in previous publications, to improve the operational range, efficiency, reliability and maintainability as compared to previous compressor skids used for this application. The 12 GeV helium compression system has five compressors configured with four pressure levels supporting three pressure levels in the new cold box. During compressor commissioning the compressors were operated independent of the cold box over a wide range of process conditions to verify proper performance including adequate cooling and oil removal. Isothermal and volumetric efficiencies over these process conditions for several built-involume ratios were obtained. This paper will discuss the operational envelope results and the modifications/improvements incorporated into the skids.

  14. The Dynamic Compression Brace for Pectus Carinatum: Intermediate Results in 286 Patients

    NARCIS (Netherlands)

    de Beer, Sjoerd A.; Gritter, Martin; de Jong, Justin R.; van Heurn, Ernst L. W.

    2017-01-01

    Dynamic brace compression is a novel treatment for patients with pectus carinatum. The dynamic compression system contains a device to measure the flexibility of the thoracic wall and regulate the pressure of the brace. Patients referred to our pediatric surgical center were screened for treatment

  15. Compression-Based Compressed Sensing

    OpenAIRE

    Rezagah, Farideh Ebrahim; Jalali, Shirin; Erkip, Elza; Poor, H. Vincent

    2016-01-01

    Modern compression algorithms exploit complex structures that are present in signals to describe them very efficiently. On the other hand, the field of compressed sensing is built upon the observation that "structured" signals can be recovered from their under-determined set of linear projections. Currently, there is a large gap between the complexity of the structures studied in the area of compressed sensing and those employed by the state-of-the-art compression codes. Recent results in the...

  16. The Role of MRI in Diagnosing Neurovascular Compression of the Cochlear Nerve Resulting in Typewriter Tinnitus.

    Science.gov (United States)

    Bae, Y J; Jeon, Y J; Choi, B S; Koo, J-W; Song, J-J

    2017-06-01

    Typewriter tinnitus, a symptom characterized by paroxysmal attacks of staccato sounds, has been thought to be caused by neurovascular compression of the cochlear nerve, but the correlation between radiologic evidence of neurovascular compression of the cochlear nerve and symptom presentation has not been thoroughly investigated. The purpose of this study was to examine whether radiologic evidence of neurovascular compression of the cochlear nerve is pathognomonic in typewriter tinnitus. Fifteen carbamazepine-responding patients with typewriter tinnitus and 8 control subjects were evaluated with a 3D T2-weighted volume isotropic turbo spin-echo acquisition sequence. Groups 1 (16 symptomatic sides), 2 (14 asymptomatic sides), and 3 (16 control sides) were compared with regard to the anatomic relation between the vascular loop and the internal auditory canal and the presence of neurovascular compression of the cochlear nerve with/without angulation/indentation. The anatomic location of the vascular loop was not significantly different among the 3 groups (all, P > .05). Meanwhile, neurovascular compression of the cochlear nerve on MR imaging was significantly higher in group 1 than in group 3 ( P = .032). However, considerable false-positive (no symptoms with neurovascular compression of the cochlear nerve on MR imaging) and false-negative (typewriter tinnitus without demonstrable neurovascular compression of the cochlear nerve) findings were also observed. Neurovascular compression of the cochlear nerve was more frequently detected on the symptomatic side of patients with typewriter tinnitus compared with the asymptomatic side of these patients or on both sides of control subjects on MR imaging. However, considering false-positive and false-negative findings, meticulous history-taking and the response to the initial carbamazepine trial should be regarded as more reliable diagnostic clues than radiologic evidence of neurovascular compression of the cochlear nerve.

  17. arXiv Recent results and future of the NA61/SHINE strong interactions program

    CERN Document Server

    Lysakowski, Bartosz

    2018-01-01

    NA61/SHINE is a fixed target experiment at the CERN Super-Proton- Synchrotron. The main goals of the experiment are to discover the critical point of strongly interacting matter and study the properties of the onset of deconfnement. In order to reach these goals the collaboration studies hadron production properties in nucleus-nucleus, proton-proton and proton-nucleus interactions. In this talk, recent results on particle production in p+p interactions, as well as Be+Be and Ar+Sc collisions in the SPS energy range are reviewed. The results are compared with available world data. The future of the NA61/SHINE scientifc program is also presented.

  18. Paraplegia aguda por compressão da medula espinhal torácica causada por tofo gotoso Acute paraplegia resulting from spinal cord compression by tophaceous gout

    Directory of Open Access Journals (Sweden)

    Eduardo Massato Hasegawa

    2007-08-01

    Full Text Available O acometimento axial pela gota é um evento raro, e o envolvimento da coluna torácica foi descrito em apenas 17 casos na literatura. Apresentamos um caso de paciente do sexo masculino de 48 anos com história de gota, sob tratamento irregular com alopurinol e colchicina, que desenvolveu paraplegia aguda decorrente de compressão medular por tofo gotoso. Realizou-se o diagnóstico por meio de ressonância magnética e anatomia patológica. Foi tratado com antiinflamatórios e descompressão cirúrgica com melhora importante, porém parcial. Apesar de o acometimento medular pelo tofo ser um evento raro, deve ser considerado nos casos de síndrome de compressão medular em pacientes com antecedente de gotaAxial gout is a rare condition and the involvement of the thoracic spine has been described only 17 times in the literature. This paper presents the case of a 48 year-old male patient with a history of gout, under irregular treatment with allopurinol and colchicines, who developed acute paraplegia resulting from spinal cord compression by tophaceous gout. The diagnosis was made using magnetic resonance imaging and anatomic pathology. The patient was treated with anti-inflammatory drugs and surgical decompression and showed important, albeit partial, improvement. Thus, although tophi rarely affect the spinal cord, they should be considered as a possibility in cases of spinal cord compression syndrome in patients with a history of gout

  19. Application of face centred central composite design to optimise compression force and tablet diameter for the formulation of mechanically strong and fast disintegrating orodispersible tablets.

    Science.gov (United States)

    Pabari, Ritesh M; Ramtoola, Zebunnissa

    2012-07-01

    A two factor, three level (3(2)) face centred, central composite design (CCD) was applied to investigate the main and interaction effects of tablet diameter and compression force (CF) on hardness, disintegration time (DT) and porosity of mannitol based orodispersible tablets (ODTs). Tablet diameters of 10, 13 and 15 mm, and CF of 10, 15 and 20 kN were studied. Results of multiple linear regression analysis show that both the tablet diameter and CF influence tablet characteristics. A negative value of regression coefficient for tablet diameter showed an inverse relationship with hardness and DT. A positive value of regression coefficient for CF indicated an increase in hardness and DT with increasing CF as a result of the decrease in tablet porosity. Interestingly, at the larger tablet diameter of 15 mm, while hardness increased and porosity decreased with an increase in CF, the DT was resistant to change. The optimised combination was a tablet of 15 mm diameter compressed at 15 kN showing a rapid DT of 37.7s and high hardness of 71.4N. Using these parameters, ODTs containing ibuprofen showed no significant change in DT (ANOVA; p>0.05) irrespective of the hydrophobicity of the ibuprofen. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Seismic Response of a Sedimentary Basin: Preliminary Results from Strong Motion Downhole Array in Taipei Basin

    Science.gov (United States)

    Young, B.; Chen, K.; Chiu, J.

    2013-12-01

    The Strong Motion Downhole Array (SMDA) is an array of 32 triggered strong motion broadband seismometers located at eight sites in Taipei Basin. Each site features three to five co-located three-component accelerometers--one at the surface and an additional two to four each down independent boreholes. Located in the center of Taipei Basin is Taipei City and the Taipei metropolitan area, the capital of Taiwan and home to more than 7 million residents. Taipei Basin is in a major seismic hazard area and is prone to frequent large earthquakes producing strong ground motion. This unique three-dimension seismic array presents new frontiers for seismic research in Taiwan and, along with it, new challenges. Frequency-dependent and site-specific amplification of seismic waves from depth to surface has been observed: preliminary results indicate that the top few tens of meters of sediment--not the entire thickness--are responsible for significant frequency-dependent amplification; amplitudes of seismic waves at the surface may be as much as seven times that at depth. Dominant amplification frequencies are interpreted as quarter-wavelength constructive interference between the surface and major interfaces in the sediments. Using surface stations with known orientation as a reference, borehole seismometer orientations in these data--which are unknown, and some of which vary considerably from event to event--have been determined using several methods. After low-pass filtering the strong motion data, iteratively rotating the two horizontal components from an individual borehole station and cross-correlating them with that from a co-located surface station has proven to be very effective. In cases where the iterative cross-correlation method does not provide a good fit, rotating both surface and borehole stations to a common axis of maximum seismic energy provides an alternative approach. The orientation-offset of a borehole station relative to the surface station may be

  1. Hemostatic Agents for Control of Intracavitary Non-Compressible Hemorrhage: An Overview of Current Results

    National Research Council Canada - National Science Library

    Kheirabadi, Bijan; Klemcke, Harold G

    2004-01-01

    The majority (̃80%) of hemorrhagic deaths on the battlefield are due to intracavitary hemorrhage that is not accessible for direct compression and cannot be treated with externally applied hemostatic agents...

  2. The creation of strongly coupled plasmas using an intense heavy ion beam: low-entropy compression of hydrogen and the problem of hydrogen metallization

    CERN Document Server

    Tahir, N A; Shutov, A; Varentsov, D; Udrea, S; Hoffmann, Dieter H H; Juranek, H; Redmer, R; Portugues, R F; Lomonosov, I V; Fortov, V E

    2003-01-01

    Intense heavy ion beams deposit energy very efficiently over extended volumes of solid density targets, thereby creating large samples of strongly coupled plasmas. Intense beams of energetic heavy ions are therefore an ideal tool to research this interesting field. It is also possible to design experiments using special beam-target geometries to achieve low-entropy compression of samples of matter. This type of experiments is of particular interest for studying the problem of hydrogen metallization. In this paper we present a design study of such a proposed experiment that will be carried out at the future heavy ion synchrotron facility SIS100, at the Gesellschaft fuer Schwerionenforschung, Darmstadt. This study has been done using a two-dimensional hydrodynamic computer code. The target consists of a solid hydrogen cylinder that is enclosed in a thick shell of lead whose one face is irradiated with an ion beam which has an annular (ring shaped) focal spot. The beam intensity and other parameters are consider...

  3. Balloon-assisted percutaneous vertebroplasty in patients with osteoporotic compression fractures - first results

    International Nuclear Information System (INIS)

    Schulte, B.U.; Trompeter, M.; Remy, C.; Reimer, P.; Bruecher, D.

    2006-01-01

    Purpose: To determine the feasibility, efficacy and safety of balloon-assisted percutaneous vertebroplasty (BA-VP) in patients with osteoporotic vertebral compression fractures (VCFs). Materials and Methods: In 47 patients (29 women, 18 men; mean age: 70 years and 4 months) with severe VCFs, 66 BA-VPs were performed via a unipedicular access. After initial puncture (under combined fluoroscopy and CT guidance) of the vertebral body (VB), the needle was retraced by 1.5 cm, and a 12-mm Fogarty balloon catheter was introduced and inflated using 2-4 ml diluted contrast media (CM). After the subsequent removal of the catheter and repositioning of the needle, vertebroplasty was performed. Results: The mean volume of PMMA injected was 4.4 ml (2.5-7.2 ml). Pain reduction (measured by the Visual Analogue Scale) was achieved in 95% of the patients, dropping from on average 8.0 preinterventionally to 2.2 after a mean follow-up of 8 months. A reduction of the pain relieving medication was achieved in 68% of the cases and patient activity improved markedly. No severe or clinically relevant complications were observed. Cement leakage occurred by filling of epidural and paravertebral veins in 9.1 and 6.1% of the cases, respectively. Leakage into the paravertebral soft tissues was seen in 3.0% of the patients and to the adjacent disc space in 10.6% of the cases. (orig.)

  4. Hydrofluoric acid burn resulting from ignition of gas from a compressed air duster.

    Science.gov (United States)

    Foster, Kevin N; Jones, LouAnn; Caruso, Daniel M

    2003-01-01

    A young female suffered burns to her hand after the ignition of gas from a compressed air duster. After debridement and dressing, the patient continued to have pain out of proportion to injury that was refractory to intravenous morphine. The material safety data sheet revealed that the chemical used was 1,1-difluoroethane. High temperatures can cause decompensation to form hydrofluoric acid. Calcium gluconate gel was applied topically to the patient's burns, which caused prompt and complete relief of her pain. A review of different compressed air duster products revealed that the main ingredient in each was a halogenated hydrocarbon. Although not considered flammable, all products have warnings regarding the possibility of ignition under various circumstances. Ignition of the gas in compressed air cleaners not only can cause flame burns, it can also cause chemical damage from exposure to hydrogen and fluoride ions. Prompt recognition and treatment is necessary to prevent severe injury.

  5. Unimodal tree size distributions possibly result from relatively strong conservatism in intermediate size classes.

    Directory of Open Access Journals (Sweden)

    Yue Bin

    Full Text Available Tree size distributions have long been of interest to ecologists and foresters because they reflect fundamental demographic processes. Previous studies have assumed that size distributions are often associated with population trends or with the degree of shade tolerance. We tested these associations for 31 tree species in a 20 ha plot in a Dinghushan south subtropical forest in China. These species varied widely in growth form and shade-tolerance. We used 2005 and 2010 census data from that plot. We found that 23 species had reversed J shaped size distributions, and eight species had unimodal size distributions in 2005. On average, modal species had lower recruitment rates than reversed J species, while showing no significant difference in mortality rates, per capita population growth rates or shade-tolerance. We compared the observed size distributions with the equilibrium distributions projected from observed size-dependent growth and mortality. We found that observed distributions generally had the same shape as predicted equilibrium distributions in both unimodal and reversed J species, but there were statistically significant, important quantitative differences between observed and projected equilibrium size distributions in most species, suggesting that these populations are not at equilibrium and that this forest is changing over time. Almost all modal species had U-shaped size-dependent mortality and/or growth functions, with turning points of both mortality and growth at intermediate size classes close to the peak in the size distribution. These results show that modal size distributions do not necessarily indicate either population decline or shade-intolerance. Instead, the modal species in our study were characterized by a life history strategy of relatively strong conservatism in an intermediate size class, leading to very low growth and mortality in that size class, and thus to a peak in the size distribution at intermediate sizes.

  6. An easy way to obtain strong duality results in linear, linear semidefinite and linear semi-infinite programming

    NARCIS (Netherlands)

    Pop, P.C.; Still, Georg J.

    1999-01-01

    In linear programming it is known that an appropriate non-homogeneous Farkas Lemma leads to a short proof of the strong duality results for a pair of primal and dual programs. By using a corresponding generalized Farkas lemma we give a similar proof of the strong duality results for semidefinite

  7. How Wage Compression Affects Job Turnover

    OpenAIRE

    Heyman, Fredrik

    2008-01-01

    I use Swedish establishment-level panel data to test Bertola and Rogerson’s (1997) hypothesis of a positive relation between the degree of wage compression and job reallocation. Results indicate that the effect of wage compression on job turnover is positive and significant in the manufacturing sector. The wage compression effect is stronger on job destruction than on job creation, consistent with downward wage rigidity. Further results include a strong positive relationship between the fract...

  8. Selecting treatment for patients with malignant epidural spinal cord compression-does age matter?: results from a randomized clinical trial.

    Science.gov (United States)

    Chi, John H; Gokaslan, Ziya; McCormick, Paul; Tibbs, Phillip A; Kryscio, Richard J; Patchell, Roy A

    2009-03-01

    Randomized clinical trial. OBJECTIVE.: To determine if age affects outcomes from differing treatments in patients with spinal metastases. Recently, class I data were published supporting surgery with radiation over radiation alone for patients with malignant epidural spinal cord compression (MESCC). However, the criteria to properly select candidates for surgery remains controversial and few independent variables which predict success after treatment have been identified. Data for this study was obtained in a randomized clinical trial comparing surgery versus radiation for MESCC. Hazard ratios were determined for the effect of age and the interaction between age and treatment. Age estimates at which prespecified relative risks could be expected were calculated with greater than 95% confidence to suggest possible age cut points for further stratification. Multivariate models and Kaplan-Meier curves were tested using stratified cohorts for both treatment groups in the randomized trial each divided into 2 age groups. Secondary data analysis with age stratification demonstrated a strong interaction between age and treatment (hazard ratio = 1.61, P = 0.01), such that as age increases, the chances of surgery being equal to radiation alone increases. The best estimate for the age at which surgery is no longer superior to radiation alone was calculated to be between 60 and 70 years of age (95% CI), using sequential prespecified relative risk ratios. Multivariate modeling and Kaplan-Meier curves for stratified treatment groups showed that there was no difference in outcome between treatments for patients >or=65 years of age. Ambulation preservation was significantly prolonged in patients variable in predicting preservation of ambulation and survival for patients being treated for spinal metastases. Our results provide compelling evidence for the first time that particular age cut points may help in selecting patients for surgical or nonsurgical intervention based on outcome.

  9. Bilateral orbital emphysema and pneumocephalus as a result of accidental compressed air exposure.

    Science.gov (United States)

    Yuksel, Murvet; Yuksel, K Zafer; Ozdemir, Gokhan; Ugur, Tuncay

    2007-01-01

    Orbital emphysema is a rare condition in the absence of trauma or sinus disease. A 22-year-old man suffering from left orbital trauma due to sudden exposure to compressed air tube was admitted with severe pain in the left eye, swelling, and mild periorbital ecchymosis. Physical examination revealed a large conjunctival laceration in the left orbit. Multislice computed tomographic scanning of the head and orbits showed extensive radiolucencies consistent with the air in both orbits, more prominent in the left. There was also subcutaneous air in the left periorbital soft tissue extending through fronto-temporal and zygomatic areas. Air was also demonstrated adjacent to the left optic canal and within the subarachnoid space intracranially. There was no evidence of any orbital, paranasal sinus, or cranial fracture. Visual acuity was minimally decreased bilaterally. The conjunctiva was sutured under local anesthesia. After 3 weeks of follow-up, the patient completely recovered without visual loss. Bilateral orbital emphysema with pneumocephalus can occur from a high-pressure compressed air injury after unilateral conjunctival trauma without any evidence of fracture.

  10. Particle production in field theories coupled to strong external sources, I: Formalism and main results

    International Nuclear Information System (INIS)

    Gelis, Francois; Venugopalan, Raju

    2006-01-01

    We develop a formalism for particle production in a field theory coupled to a strong time-dependent external source. An example of such a theory is the color glass condensate. We derive a formula, in terms of cut vacuum-vacuum Feynman graphs, for the probability of producing a given number of particles. This formula is valid to all orders in the coupling constant. The distribution of multiplicities is non-Poissonian, even in the classical approximation. We investigate an alternative method of calculating the mean multiplicity. At leading order, the average multiplicity can be expressed in terms of retarded solutions of classical equations of motion. We demonstrate that the average multiplicity at next-to-leading order can be formulated as an initial value problem by solving equations of motion for small fluctuation fields with retarded boundary conditions. The variance of the distribution can be calculated in a similar fashion. Our formalism therefore provides a framework to compute from first principles particle production in proton-nucleus and nucleus-nucleus collisions beyond leading order in the coupling constant and to all orders in the source density. We also provide a transparent interpretation (in conventional field theory language) of the well-known Abramovsky-Gribov-Kancheli (AGK) cancellations. Explicit connections are made between the framework for multi-particle production developed here and the framework of reggeon field theory

  11. The intravertebral vacuum phenomen as specific sign of osteonecrosis in vertebral compression fractures: results from a radiological and histological study

    Energy Technology Data Exchange (ETDEWEB)

    Libicher, Martin [University of Cologne, Department of Radiology, Koeln (Germany); Appelt, Andreas; Baier, Martin; Meeder, Peter-Juergen; DaFonseca, Katharina [University of Heidelberg, Department of Trauma Surgery, Heidelberg (Germany); Berger, Irina [University of Heidelberg, Department of Pathology, Heidelberg (Germany); Grafe, Ingo; Kasperk, Christian [University of Heidelberg, Department of Internal Medicine, Division of Osteology, Heidelberg (Germany); Noeldge, Gerd [University of Heidelberg, Department of Radiology, Heidelberg (Germany)

    2007-09-15

    This study investigated the prevalence of the intravertebral vacuum phenomenon (IVP) and osteonecroses in vertebral compression fractures (VCFs). We therefore performed an histological analysis of biopsies obtained from VCFs prior to balloon kyphoplasty. Computed tomography (CT) scans were reviewed regarding the presence of an IVP (i.e. cleft sign, Kuemmell disease). We reviewed the data of 266 consecutive patients treated by balloon kyphoplasty in 501 procedures from 2002 to 2004. From 180 patients (68%) we obtained adequate bone tissue for histological evaluation. Biopsy specimens were analysed regarding the presence of osteoporosis, infection, malignancy and osteonecrosis. CT scans of all 180 patients were reviewed for presence of an IVP. Histological examination revealed 135 (75%) osteoporoses, 20 (11%) neoplasms, 12 (7%) trauma cases and 13 (7%) osteonecroses. An IVP was present in 12 (7%) patients. There was a significant association of osteonecrosis and IVP (P < 0.0001). Eleven of 12 patients with a vacuum phenomenon showed an osteonecrosis on histology, wheras 11 of 13 patients with osteonecrosis showed an IVP on CT. The IVP is a specific sign of osteonecrosis in vertebral compression fractures (sensitivity 85%, specificity 99%, positive predictive value 91%). Our findings strongly support the thesis that an IVP indicates local bone ischemia associated with a non-healing vertebral collapse and pseudarthrosis. (orig.)

  12. Quantum dot DNA bioconjugates: attachment chemistry strongly influences the resulting composite architecture.

    Science.gov (United States)

    Boeneman, Kelly; Deschamps, Jeffrey R; Buckhout-White, Susan; Prasuhn, Duane E; Blanco-Canosa, Juan B; Dawson, Philip E; Stewart, Michael H; Susumu, Kimihiro; Goldman, Ellen R; Ancona, Mario; Medintz, Igor L

    2010-12-28

    The unique properties provided by hybrid semiconductor quantum dot (QD) bioconjugates continue to stimulate interest for many applications ranging from biosensing to energy harvesting. Understanding both the structure and function of these composite materials is an important component in their development. Here, we compare the architecture that results from using two common self-assembly chemistries to attach DNA to QDs. DNA modified to display either a terminal biotin or an oligohistidine peptidyl sequence was assembled to streptavidin/amphiphilic polymer- or PEG-functionalized QDs, respectively. A series of complementary acceptor dye-labeled DNA were hybridized to different positions on the DNA in each QD configuration and the separation distances between the QD donor and each dye-acceptor probed with Förster resonance energy transfer (FRET). The polyhistidine self-assembly yielded QD-DNA bioconjugates where predicted and experimental separation distances matched reasonably well. Although displaying efficient FRET, data from QD-DNA bioconjugates assembled using biotin-streptavidin chemistry did not match any predicted separation distances. Modeling based upon known QD and DNA structures along with the linkage chemistry and FRET-derived distances was used to simulate each QD-DNA structure and provide insight into the underlying architecture. Although displaying some rotational freedom, the DNA modified with the polyhistidine assembles to the QD with its structure extended out from the QD-PEG surface as predicted. In contrast, the random orientation of streptavidin on the QD surface resulted in DNA with a wide variety of possible orientations relative to the QD which cannot be controlled during assembly. These results suggest that if a particular QD biocomposite structure is desired, for example, random versus oriented, the type of bioconjugation chemistry utilized will be a key influencing factor.

  13. Quantum Dot DNA Bioconjugates: Attachment Chemistry Strongly Influences the Resulting Composite Architecture

    Science.gov (United States)

    Boeneman, Kelly; Deschamps, Jeffrey R.; Buckhout-White, Susan; Prasuhn, Duane E.; Blanco-Canosa, Juan B.; Dawson, Philip E.; Stewart, Michael H.; Susumu, Kimihiro; Goldman, Ellen R.; Ancona, Mario; Medintz, Igor L.

    2010-01-01

    The unique properties provided by hybrid semiconductor quantum dot- (QD) bioconjugates continue to stimulate interest for many applications ranging from biosensing to energy harvesting. Understanding both the structure and function of these composite materials is an important component in their development. Here, we compare the architecture that results from using two common self-assembly chemistries to attach DNA to QDs. DNA modified to display either a terminal biotin or an oligohistidine peptidyl sequence was assembled to streptavidin/amphiphilic polymer- or PEG-functionalized QDs, respectively. A series of complementary acceptor dye-labeled DNA were hybridized to different positions on the DNA in each QD configuration and the separation distances between the QD donor and each dye-acceptor probed with Förster resonance energy transfer (FRET). The polyhistidine self-assembly yielded QD-DNA bioconjugates where predicted and experimental separation distances matched reasonably well. Although displaying efficient FRET, data from QD-DNA bioconjugates assembled using biotin-streptavidin chemistry did not match any predicted separation distances. Modeling based upon known QD and DNA structures along with the linkage chemistry and FRET-derived distances was used to simulate each QD-DNA structure and provide insight into the underlying architecture. Although displaying some rotational freedom, the DNA modified with the polyhistidine assembles to the QD with its structure extended out from the QD-PEG surface as predicted. In contrast, the random orientation of streptavidin on the QD surface resulted in DNA with a wide variety of possible orientations relative to the QD which cannot be controlled during assembly. These results suggest that if a particular QD-biocomposite structure is desired, for example, random versus oriented, the type of bioconjugation chemistry utilized will be a key influencing factor. PMID:21082822

  14. Advances in compressible turbulent mixing

    Energy Technology Data Exchange (ETDEWEB)

    Dannevik, W.P.; Buckingham, A.C.; Leith, C.E. [eds.

    1992-01-01

    This volume includes some recent additions to original material prepared for the Princeton International Workshop on the Physics of Compressible Turbulent Mixing, held in 1988. Workshop participants were asked to emphasize the physics of the compressible mixing process rather than measurement techniques or computational methods. Actual experimental results and their meaning were given precedence over discussions of new diagnostic developments. Theoretical interpretations and understanding were stressed rather than the exposition of new analytical model developments or advances in numerical procedures. By design, compressibility influences on turbulent mixing were discussed--almost exclusively--from the perspective of supersonic flow field studies. The papers are arranged in three topical categories: Foundations, Vortical Domination, and Strongly Coupled Compressibility. The Foundations category is a collection of seminal studies that connect current study in compressible turbulent mixing with compressible, high-speed turbulent flow research that almost vanished about two decades ago. A number of contributions are included on flow instability initiation, evolution, and transition between the states of unstable flow onset through those descriptive of fully developed turbulence. The Vortical Domination category includes theoretical and experimental studies of coherent structures, vortex pairing, vortex-dynamics-influenced pressure focusing. In the Strongly Coupled Compressibility category the organizers included the high-speed turbulent flow investigations in which the interaction of shock waves could be considered an important source for production of new turbulence or for the enhancement of pre-existing turbulence. Individual papers are processed separately.

  15. Comparative analysis of analytical and experimental results of the strength of compressed reinforced concrete columns under special combinations of loads

    Directory of Open Access Journals (Sweden)

    Tamrazyan Ashot

    2016-01-01

    Full Text Available The article presents a comparison of results of experimental and analytical calculations of the strength of the central and eccentrically compressed concrete elements working in the conditions of dynamic loads under fire exposure. The diagram shows a coefficient of dynamic strength depending on the dynamic loading under high temperature obtained by experimentation way. It is shown, that accounting the dynamic effects in fire condition reduces the load carrying capacity of columns by 40%. Therefore, it is recommended to check the possibility of progressive collapse of buildings and, results of which, appearing the character of dynamic loads on the structure, in calculating load carrying capacity of the structure in fire testing.

  16. EARLY RESULTS OF UNSTABLE DISTAL RADIUS FRACTURES- ORIF WITH LOCKING COMPRESSION PLATE VERSUS LIGAMENTOTAXIS WITH EXTERNAL FIXATORS

    Directory of Open Access Journals (Sweden)

    Mondeep Gayan

    2017-04-01

    Full Text Available BACKGROUND External Fixation (EF and Open Reduction and Internal Fixation (ORIF have been the traditional surgical modalities for unstable distal radius fractures. The Locking Compression Plates (LCP acting as “internal external fixators” are particularly valuable in difficult situations of fractures. We undertook a study to evaluate the outcome of unstable distal radius fractures treated with ORIF with LCP versus those treated by ligamentotaxis with external fixators. MATERIALS AND METHODS A comparative study was carried out in a tertiary care centre with 30 cases of unstable distal radius fractures (15 cases in each group. In one group, open reduction and internal fixation with distal radius volar locking compression plate was carried out and in the other group ligamentotaxis with external fixator was done. The patients were treated and followed up over a period of one and a half year between June 2011 to November 2012. The fractures were classified according to AO classification (Arbeitsgemeinschaft für Osteosynthesefragen: German for “Association for the Study of Internal Fixation” or AO. The functional results were evaluated at the end of 6 months according to Demerit point system of Gartland and Werley modified by Sarmiento (1975 and the anatomical results as per Lindstrom criteria (1959 modified by Sarmiento (1980. RESULTS Overall 86.66% (13 cases had good-to-excellent anatomical results in external fixator group as compared to 93.33% (14 cases in LCP group. The functional outcome was excellent in 80% (12 and good in 13.33% (2 cases in external fixator group as compared to 66.66% (10 excellent and 26.66% (4 good in LCP group. CONCLUSION Both open reduction and internal fixation with locking compression plate and ligamentotaxis with external fixators are good treatment modalities for unstable distal radius fractures. However, the choice should be guided by the fracture configuration, surgeons’ experience and patient’s profile.

  17. Diffusion tensor imaging and fiber tractography in cervical compressive myelopathy: preliminary results

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Kim, Jae Hyoung; Park, Jong Bin; Lee, Guen Young; Kang, Heung Sik; Park, Kun Woo; Yeom, Jin S.

    2011-01-01

    To assess diffusion tensor imaging (DTI) parameters in cervical compressive myelopathy (CCM) patients compared to normal volunteers, to relate them with myelopathy severity, and to relate tractography patterns with postoperative neurologic improvement. Twenty patients suffering from CCM were prospectively enrolled (M:F = 13:7, mean age, 49.6 years; range 22-67 years) from September 2009 to March 2010. Sensitivity encoding (SENSE) single-shot echo-planar imaging (EPI) was used for the sagittal DTI. Twenty sex- and age-matched normal volunteers underwent the same scanning procedure. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values in the spinal cord were compared between the patients and normal volunteers and were related to myelopathy severity based on Japanese Orthopedic Association (JOA) scores. Tractography patterns were related to myelopathy severity and postoperative improvement. There were significant differences between patients and normal volunteers in terms of FA (0.498 ± 0.114 vs. 0.604 ± 0.057; p = 0.001) and ADC (1.442 ± 0.389 vs. 1.169 ± 0.098; p = 0.001). DTI parameters and tractography patterns were not related to myelopathy severity. In ten patients in the neurologically worse group, postoperative neurologic improvement was seen in four of five patients with intact fiber tracts, but only one of five patients with interrupted fiber tracts exhibited neurologic improvement. DTI parameters in CCM patients were significantly different from those in normal volunteers but were not significantly related to myelopathy severity. The patterns of tractography appear to correlate with postoperative neurologic improvement. (orig.)

  18. Neuroblastoma with symptomatic spinal cord compression at diagnosis: treatment and results with 76 cases.

    Science.gov (United States)

    De Bernardi B; Pianca, C; Pistamiglio, P; Veneselli, E; Viscardi, E; Pession, A; Alvisi, P; Carli, M; Donfrancesco, A; Casale, F; Giuliano, M G; di Montezemolo, L C; Di Cataldo, A; Lo Curto, M; Bagnulo, S; Schumacher, R F; Tamburini, A; Garaventa, A; Clemente, L; Bruzzi, P

    2001-01-01

    To report on the treatment of patients with newly diagnosed neuroblastoma presenting with spinal cord compression (SCC). Of 1,462 children with neuroblastoma registered between 1979 and 1998, 76 (5.2%) presented with signs/symptoms of SCC, including motor deficit in 75 patients (mild in 43, moderate in 22, severe [ie, paraplegia] in 10), pain in 47, sphincteric deficit in 30, and sensory loss in 11. Treatment of SCC consisted of radiotherapy in 11 patients, laminectomy in 32, and chemotherapy in 33. Laminectomy was more frequently performed in cases with favorable disease stages and in those with severe motor deficit, whereas chemotherapy was preferred in patients with advanced disease. Thirty-three patients achieved full neurologic recovery, 14 improved, 22 remained stable, and eight worsened, including three who become paraplegic. None of the 10 patients with grade 3 motor deficit, eight of whom were treated by laminectomy, recovered or improved. In the other 66 patients, the neurologic response to treatment was comparable for the three therapeutic modalities. All 11 patients treated by radiotherapy and 26 of 32 patients treated by laminectomy, but only two of 33 treated by chemotherapy, received additional therapy for SCC. Fifty-four of 76 patients are alive at time of the analysis, with follow-up of 4 to 209 months (median, 139 months). Twenty-six (44%) of 54 survivors have late sequelae, mainly scoliosis and sphincteric deficit. Radiotherapy, laminectomy, and chemotherapy showed comparable ability to relieve or improve SCC. However, patients treated with chemotherapy usually did not require additional therapy, whereas patients treated either with radiotherapy or laminectomy commonly did. No patient presenting with (or developing) severe motor deficit recovered or improved. Sequelae were documented in 44% of surviving patients.

  19. Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results.

    Science.gov (United States)

    Nett, Brian E; Brauweiler, Robert; Kalender, Willi; Rowley, Howard; Chen, Guang-Hong

    2010-04-21

    Micro-CT scanning has become an accepted standard for anatomical imaging in small animal disease and genome mutation models. Concurrently, perfusion imaging via tracking contrast dynamics after injection of an iodinated contrast agent is a well-established tool for clinical CT scanners. However, perfusion imaging is not yet commercially available on the micro-CT platform due to limitations in both radiation dose and temporal resolution. Recent hardware developments in micro-CT scanners enable continuous imaging of a given volume through the use of a slip-ring gantry. Now that dynamic CT imaging is feasible, data may be acquired to measure tissue perfusion using a micro-CT scanner (CT Imaging, Erlangen, Germany). However, rapid imaging using micro-CT scanners leads to high image noise in individual time frames. Using the standard filtered backprojection (FBP) image reconstruction, images are prohibitively noisy for calculation of voxel-by-voxel perfusion maps. In this study, we apply prior image constrained compressed sensing (PICCS) to reconstruct images with significantly lower noise variance. In perfusion phantom experiments performed on a micro-CT scanner, the PICCS reconstruction enabled a reduction to 1/16 of the noise variance of standard FBP reconstruction, without compromising the spatial or temporal resolution. This enables a significant increase in dose efficiency, and thus, significantly less exposure time is needed to acquire images amenable to perfusion processing. This reduction in required irradiation time enables voxel-by-voxel perfusion maps to be generated on micro-CT scanners. Sample perfusion maps using a deconvolution-based perfusion analysis are included to demonstrate the improvement in image quality using the PICCS algorithm.

  20. Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results

    International Nuclear Information System (INIS)

    Nett, Brian E; Chen, G-H; Brauweiler, Robert; Kalender, Willi; Rowley, Howard

    2010-01-01

    Micro-CT scanning has become an accepted standard for anatomical imaging in small animal disease and genome mutation models. Concurrently, perfusion imaging via tracking contrast dynamics after injection of an iodinated contrast agent is a well-established tool for clinical CT scanners. However, perfusion imaging is not yet commercially available on the micro-CT platform due to limitations in both radiation dose and temporal resolution. Recent hardware developments in micro-CT scanners enable continuous imaging of a given volume through the use of a slip-ring gantry. Now that dynamic CT imaging is feasible, data may be acquired to measure tissue perfusion using a micro-CT scanner (CT Imaging, Erlangen, Germany). However, rapid imaging using micro-CT scanners leads to high image noise in individual time frames. Using the standard filtered backprojection (FBP) image reconstruction, images are prohibitively noisy for calculation of voxel-by-voxel perfusion maps. In this study, we apply prior image constrained compressed sensing (PICCS) to reconstruct images with significantly lower noise variance. In perfusion phantom experiments performed on a micro-CT scanner, the PICCS reconstruction enabled a reduction to 1/16 of the noise variance of standard FBP reconstruction, without compromising the spatial or temporal resolution. This enables a significant increase in dose efficiency, and thus, significantly less exposure time is needed to acquire images amenable to perfusion processing. This reduction in required irradiation time enables voxel-by-voxel perfusion maps to be generated on micro-CT scanners. Sample perfusion maps using a deconvolution-based perfusion analysis are included to demonstrate the improvement in image quality using the PICCS algorithm.

  1. Experimental and Numerical Evaluation of the Mechanical Behavior of Strongly Anisotropic Light-Weight Metallic Fiber Structures under Static and Dynamic Compressive Loading

    Directory of Open Access Journals (Sweden)

    Olaf Andersen

    2016-05-01

    Full Text Available Rigid metallic fiber structures made from a variety of different metals and alloys have been investigated mainly with regard to their functional properties such as heat transfer, pressure drop, or filtration characteristics. With the recent advent of aluminum and magnesium-based fiber structures, the application of such structures in light-weight crash absorbers has become conceivable. The present paper therefore elucidates the mechanical behavior of rigid sintered fiber structures under quasi-static and dynamic loading. Special attention is paid to the strongly anisotropic properties observed for different directions of loading in relation to the main fiber orientation. Basically, the structures show an orthotropic behavior; however, a finite thickness of the fiber slabs results in moderate deviations from a purely orthotropic behavior. The morphology of the tested specimens is examined by computed tomography, and experimental results for different directions of loading as well as different relative densities are presented. Numerical calculations were carried out using real structural data derived from the computed tomography data. Depending on the direction of loading, the fiber structures show a distinctively different deformation behavior both experimentally and numerically. Based on these results, the prevalent modes of deformation are discussed and a first comparison with an established polymer foam and an assessment of the applicability of aluminum fiber structures in crash protection devices is attempted.

  2. Development of a biaxial compression device for biological samples: preliminary experimental results for a closed cell foam.

    Science.gov (United States)

    Little, J P; Tevelen, G; Adam, C J; Evans, J H; Pearcy, M J

    2009-07-01

    Biological tissues are subjected to complex loading states in vivo and in order to define constitutive equations that effectively simulate their mechanical behaviour under these loads, it is necessary to obtain data on the tissue's response to multiaxial loading. Single axis and shear testing of biological tissues is often carried out, but biaxial testing is less common. We sought to design and commission a biaxial compression testing device, capable of obtaining repeatable data for biological samples. The apparatus comprised a sealed stainless steel pressure vessel specifically designed such that a state of hydrostatic compression could be created on the test specimen while simultaneously unloading the sample along one axis with an equilibrating tensile pressure. Thus a state of equibiaxial compression was created perpendicular to the long axis of a rectangular sample. For the purpose of calibration and commissioning of the vessel, rectangular samples of closed cell ethylene vinyl acetate (EVA) foam were tested. Each sample was subjected to repeated loading, and nine separate biaxial experiments were carried out to a maximum pressure of 204 kPa (30 psi), with a relaxation time of two hours between them. Calibration testing demonstrated the force applied to the samples had a maximum error of 0.026 N (0.423% of maximum applied force). Under repeated loading, the foam sample demonstrated lower stiffness during the first load cycle. Following this cycle, an increased stiffness, repeatable response was observed with successive loading. While the experimental protocol was developed for EVA foam, preliminary results on this material suggest that this device may be capable of providing test data for biological tissue samples. The load response of the foam was characteristic of closed cell foams, with consolidation during the early loading cycles, then a repeatable load-displacement response upon repeated loading. The repeatability of the test results demonstrated the

  3. Treatment by medical compression stockings among 144 consecutive patients with non-complicated primary varicose veins: results on compliance.

    Science.gov (United States)

    Rastel, D

    2014-12-01

    Compression stockings are the major long-term treatment of non-complicated primary varicose veins recommended by international consensus. Nevertheless there are few data concerning the patient compliance to treatment. Hundred and forty-four patients with varicose veins of primary origin were prospectively recruited and questioned about their compression therapy: 29.2% patients are wearing compression stockings, and for 10.4% on a daily basis; 32.6% do not wear their compression mainly because it is not well tolerated; 38.2% do not have compression treatment because it is not recommended or not prescribed by the physician. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  4. Statistical Analysis of Compressive and Flexural Test Results on the Sustainable Adobe Reinforced with Steel Wire Mesh

    Science.gov (United States)

    Jokhio, Gul A.; Syed Mohsin, Sharifah M.; Gul, Yasmeen

    2018-04-01

    It has been established that Adobe provides, in addition to being sustainable and economic, a better indoor air quality without spending extensive amounts of energy as opposed to the modern synthetic materials. The material, however, suffers from weak structural behaviour when subjected to adverse loading conditions. A wide range of mechanical properties has been reported in literature owing to lack of research and standardization. The present paper presents the statistical analysis of the results that were obtained through compressive and flexural tests on Adobe samples. Adobe specimens with and without wire mesh reinforcement were tested and the results were reported. The statistical analysis of these results presents an interesting read. It has been found that the compressive strength of adobe increases by about 43% after adding a single layer of wire mesh reinforcement. This increase is statistically significant. The flexural response of Adobe has also shown improvement with the addition of wire mesh reinforcement, however, the statistical significance of the same cannot be established.

  5. Anomalous scaling of passive scalar fields advected by the Navier-Stokes velocity ensemble: effects of strong compressibility and large-scale anisotropy.

    Science.gov (United States)

    Antonov, N V; Kostenko, M M

    2014-12-01

    The field theoretic renormalization group and the operator product expansion are applied to two models of passive scalar quantities (the density and the tracer fields) advected by a random turbulent velocity field. The latter is governed by the Navier-Stokes equation for compressible fluid, subject to external random force with the covariance ∝δ(t-t')k(4-d-y), where d is the dimension of space and y is an arbitrary exponent. The original stochastic problems are reformulated as multiplicatively renormalizable field theoretic models; the corresponding renormalization group equations possess infrared attractive fixed points. It is shown that various correlation functions of the scalar field, its powers and gradients, demonstrate anomalous scaling behavior in the inertial-convective range already for small values of y. The corresponding anomalous exponents, identified with scaling (critical) dimensions of certain composite fields ("operators" in the quantum-field terminology), can be systematically calculated as series in y. The practical calculation is performed in the leading one-loop approximation, including exponents in anisotropic contributions. It should be emphasized that, in contrast to Gaussian ensembles with finite correlation time, the model and the perturbation theory presented here are manifestly Galilean covariant. The validity of the one-loop approximation and comparison with Gaussian models are briefly discussed.

  6. Results and analyses of the smoke from compression ignition CI engines (diesel)

    International Nuclear Information System (INIS)

    Dimitrovski, Mile; Mitreski, Stevo M.

    1998-01-01

    The aim of this examination is to improve the knowledge about the actual ecological condition which is a result of the gas and particles emission from the diesel engines. The mechanism of the production of combustion products including the particles in the combustion chamber has been studied, as well as the options for reduction of the emission. Measurements of the smoke emission from the vehicles in Skopje have been made and the results are given, including their analyses. The conclusion from the analyses is that it is necessary to improve the conditions for normal use of the diesel engine vehicles, as well as to engage new vehicles which cause less damage for the environment (Author)

  7. EVALUATION OF RESULTS IN FRACTURES OF BOTH BONES FOREARM TREATED WITH DYNAMIC COMPRESSION PLATING

    Directory of Open Access Journals (Sweden)

    Sindhuja G

    2017-06-01

    Full Text Available BACKGROUND The anatomical alignment of the bones, the length, the radial bow, and axis should be restored for a good functional outcome. Conservative treatment has resulted in malunion, non-union, synostosis and ultimately poor functional outcome. Internal fixation helps in perfect reduction of fracture fragments in anatomical position by rigid fixation and early mobilisation, the normal functions of the hand can be re-achieved at the earliest. This study has been taken up to evaluate the results of open reduction and internal fixation of the fractures of BBFA with DCP in adults and its advantages and complications. In this study, the rate and time taken for union, the complication, the functional results in terms of forearm rotation and wrist and elbow movements are evaluated. MATERIALS AND METHODS This study includes treatment of 20 cases of fracture of both bones of forearm by open reduction and internal fixation with 3.5 mm DCP from August 2013 to August 2015 at Department of Orthopaedics at Konaseema Institute of Medical Sciences, Amalapuram. Follow-up was done up to September 2015. This is a prospective time bound study. Sample size - 20 patients. Inclusion Criteria- 1. Simple fractures. 2. Open fractures-Gustilo and Anderson type I and type II. 3. Age criteria = 15 to 70 years, both males and females. Exclusion Criteria- 1. Age criteria 0 to 14 years & > 70 years. 2. Radiologically proven segmental fractures and isolated forearm bone fractures. 3. Pathological fracture. 4. Gustilo and Anderson type III. 5. Patient not willing for surgery. 6. Patient unfit for surgery. RESULTS The present study consists of 20 cases of fracture both bones of the forearm. All the cases were openly reduced and internally fixed with 3.5 mm DCP. The study period was from August 2013 to September 2015. The age of these patients ranged from 15-70 years with fracture being most common in 3 rd decade and an average age of 31 years. CONCLUSION Use of separate

  8. Unveil Compressed Sensing

    OpenAIRE

    Liu, Xiteng

    2013-01-01

    We discuss the applicability of compressed sensing theory. We take a genuine look at both experimental results and theoretical works. We answer the following questions: 1) What can compressed sensing really do? 2) More importantly, why?

  9. Preliminary Results for the Treatment of a Pain-Causing Osteoporotic Vertebral Compression Fracture with a Sky Bone Expander

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jin Bo; Tang, Xue Ming; Xu, Nan Wei; Bao, Hong Tao [Changzhou No 2. Hospital, Changzhou (China)

    2008-10-15

    Vertebral compression fractures (VCFs) are common complications of osteoporosis. The expansion of VCFs with a Sky Bone Expander is a new procedure which improves kyphotic deformities and decreases pain associated with VCFs. The purpose of this study was to investigate the preliminary results for the treatment of painful osteoporotic VCFs with a Sky Bone Expander. Twenty-six patients with pain-causing VCFs were treated with a Sky Bone Expander. This operation involved the percutaneous insertion of the Sky Bone Expander into a fractured vertebral body transpedicularly. Following the expansion, the Sky Bone Expander was contracted and removed, resulting in a cavity to be filled with bone cement. All fractures were analyzed for improvement in sagittal alignment. Clinical complications, pain relief and ambulation status were evaluated 1 day, 1 week, 1 month, and 3 months after the operation. Twenty-four hours after the operation, all the patients treated experienced some degree of pain relief. In addition, no postoperative neurologic complications were noted. The average operative time was 42.4 {+-} 15.5 min per vertebra. Moreover, an average cement volume of 3.5 mL (range, 2.5 {+-} 5.0 mL) was injected per vertebra. The average anterior height was 18.4 {+-} 5.1 mm preoperatively and 20.5 {+-} 5.3 mm postoperatively (p < 0.01). Furthermore, the average midline height was 15.5 {+-} 5.2 mm preoperatively and 18.9 {+-} 4.0 mm postoperatively (p < 0.01). The Cobb angle improved from 18.5 {+-} 8.2 degrees preoperatively to 9.2 {+-} 4.0 degrees postoperatively (p < 0.01). The Visual Anabog Scale scores decreased from 7.7 {+-} 1.8 points preoperatively to 3.1 {+-} 2.0, 2.9 {+-} 1.7, 2.6 {+-} 1.5 and 2.9 {+-} 11.3 after 1 day, 1 week, 1 month and 3 months after the operation, respectively. Cement extrusion was observed in four patients without any neurologic symptoms. As a result of this study, we can postulate that the expansion of compressed vetrebra with a Sky Bone Expander

  10. Compression in Working Memory and Its Relationship With Fluid Intelligence.

    Science.gov (United States)

    Chekaf, Mustapha; Gauvrit, Nicolas; Guida, Alessandro; Mathy, Fabien

    2018-03-10

    Working memory has been shown to be strongly related to fluid intelligence; however, our goal is to shed further light on the process of information compression in working memory as a determining factor of fluid intelligence. Our main hypothesis was that compression in working memory is an excellent indicator for studying the relationship between working-memory capacity and fluid intelligence because both depend on the optimization of storage capacity. Compressibility of memoranda was estimated using an algorithmic complexity metric. The results showed that compressibility can be used to predict working-memory performance and that fluid intelligence is well predicted by the ability to compress information. We conclude that the ability to compress information in working memory is the reason why both manipulation and retention of information are linked to intelligence. This result offers a new concept of intelligence based on the idea that compression and intelligence are equivalent problems. © 2018 Cognitive Science Society, Inc.

  11. Comparison of changes in tidal volume associated with expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation.

    Science.gov (United States)

    Morino, Akira; Shida, Masahiro; Tanaka, Masashi; Sato, Kimihiro; Seko, Toshiaki; Ito, Shunsuke; Ogawa, Shunichi; Takahashi, Naoaki

    2015-07-01

    [Purpose] This study was designed to compare and clarify the relationship between expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation, with a focus on tidal volume. [Subjects and Methods] The subjects were 18 patients on prolonged mechanical ventilation, who had undergone tracheostomy. Each patient received expiratory rib cage compression and expiratory abdominal compression; the order of implementation was randomized. Subjects were positioned in a 30° lateral recumbent position, and a 2-kgf compression was applied. For expiratory rib cage compression, the rib cage was compressed unilaterally; for expiratory abdominal compression, the area directly above the navel was compressed. Tidal volume values were the actual measured values divided by body weight. [Results] Tidal volume values were as follows: at rest, 7.2 ± 1.7 mL/kg; during expiratory rib cage compression, 8.3 ± 2.1 mL/kg; during expiratory abdominal compression, 9.1 ± 2.2 mL/kg. There was a significant difference between the tidal volume during expiratory abdominal compression and that at rest. The tidal volume in expiratory rib cage compression was strongly correlated with that in expiratory abdominal compression. [Conclusion] These results indicate that expiratory abdominal compression may be an effective alternative to the manual breathing assist procedure.

  12. A strong association between non-musculoskeletal symptoms and musculoskeletal pain symptoms: results from a population study

    Directory of Open Access Journals (Sweden)

    Tschudi-Madsen Hedda

    2011-12-01

    Full Text Available Abstract Background There is a lack of knowledge about the pattern of symptom reporting in the general population as most research focuses on specific diseases or symptoms. The number of musculoskeletal pain sites is a strong predictor for disability pensioning and, hence, is considered to be an important dimension in symptom reporting. The simple method of counting symptoms might also be applicable to non-musculoskeletal symptoms, rendering further dimensions in describing individual and public health. In a general population, we aimed to explore the association between self-reported non-musculoskeletal symptoms and the number of pain sites. Methods With a cross-sectional design, the Standardised Nordic Questionnaire and the Subjective Health Complaints Inventory were used to record pain at ten different body sites and 13 non-musculoskeletal symptoms, respectively, among seven age groups in Ullensaker, Norway (n = 3,227. Results Results showed a strong, almost linear relationship between the number of non-musculoskeletal symptoms and the number of pain sites (r = 0.55. The number and type of non-musculoskeletal symptoms had an almost equal explanatory power in the number of pain sites reported (27.1% vs. 28.2%. Conclusion The linear association between the number of non-musculoskeletal and musculoskeletal symptoms might indicate that the symptoms share common characteristics and even common underlying causal factors. The total burden of symptoms as determined by the number of symptoms reported might be an interesting generic indicator of health and well-being, as well as present and future functioning. Research on symptom reporting might also be an alternative pathway to describe and, possibly, understand the medically unexplained multisymptom conditions.

  13. Hyperspectral data compression

    CERN Document Server

    Motta, Giovanni; Storer, James A

    2006-01-01

    Provides a survey of results in the field of compression of remote sensed 3D data, with a particular interest in hyperspectral imagery. This work covers topics such as compression architecture, lossless compression, lossy techniques, and more. It also describes a lossless algorithm based on vector quantization.

  14. Percutaneous Stabilization System Osseofix® for Treatment of Osteoporotic Vertebral Compression Fractures - Clinical and Radiological Results after 12 Months.

    Directory of Open Access Journals (Sweden)

    Stephan Albrecht Ender

    Full Text Available A prospective consecutive cohort study (follow-up study.Our study investigated whether implantation of an expandable titanium mesh cage (Osseofix® is a successful and safe minimally invasive therapy for osteoporotic vertebral compression fractures (VCF. Our experiences, clinical and radiological findings after 12 months follow-up are presented. Kypho- and vertebroplasty are well-established minimally invasive procedures for the treatment of osteoporotic VCF. The main complications associated with both procedures are uncontrolled bone cement leakage. Therefore a suitable alternative has been investigated.During June 2010 to May 2011 24 patients were included with 32 osteoporotic VCF (T6 to L4. All of them were stabilized with the Osseofix® system. Preinterventionally we performed X-ray, MRI, and bone density measurements (DXA. Clinical and radiological results were evaluated preop., postop. and after 12 months postop. based on the Oswestry Disability Index (ODI and the Visual Analogue Scale (VAS, X-ray (Beck Index, Cobb-angle and CT.There was a significant improvement in the mean ODI (70,6% to 30,1% as well as a significant reduction in pain intensity (VAS (7,7 to 1,4 after 12 month. The mean kyphotic angle according to Cobb showed significant improvements (11,7° to 10,4° after 12 months. Postinterventional imaging showed only one case of loss of height in a stabilized vertebral body (3.1%. We saw no changes in posterior vertebral wall or adjacent fractures. Except for one pronounced postoperative hematoma we saw no surgical complications including no cement leakage.Stabilization of symptomatic osteoporotic VCF with Osseofix® system is a safe and effective procedure, even in fractures with posterior wall involvement. The clinical mid-term results are good at a very low complication rate. The Osseofix® system is an interesting alternative to the established procedures of cement augmentation.

  15. Strong similarities in the creep and damage behaviour of a synthetic bone model compared to human trabecular bone under compressive cyclic loading.

    Science.gov (United States)

    Purcell, Philip; Tiernan, Stephen; McEvoy, Fiona; Morris, Seamus

    2015-08-01

    Understanding the failure modes which instigate vertebral collapse requires the determination of trabecular bone fatigue properties, since many of these fractures are observed clinically without any preceding overload event. Alternatives to biological bone tissue for in-vitro fatigue studies are available in the form of commercially available open cell polyurethane foams. These test surrogates offer particular advantages compared to biological tissue such as a controllable architecture and greater uniformity. The present study provides a critical evaluation of these models as a surrogate to human trabecular bone tissue for the study of vertebral augmentation treatments such as balloon kyphoplasty. The results of this study show that while statistically significant differences were observed for the damage response of the two materials, both share a similar three phase modulus reduction over their life span with complete failure rapidly ensuing at damage levels above 30%. No significant differences were observed for creep accumulation properties, with greater than 50% of creep strains being accumulated during the first quarter of the life span for both materials. A significant power law relationship was identified between damage accumulation rate and cycles to failure for the synthetic bone model along with comparable microarchitectural features and a hierarchical composite structure consistent with biological bone. These findings illustrate that synthetic bone models offer potential as a surrogate for trabecular bone to an extent that warrants a full validation study to define boundaries of use which compliment traditional tests using biological bone. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. "Compressed" Compressed Sensing

    OpenAIRE

    Reeves, Galen; Gastpar, Michael

    2010-01-01

    The field of compressed sensing has shown that a sparse but otherwise arbitrary vector can be recovered exactly from a small number of randomly constructed linear projections (or samples). The question addressed in this paper is whether an even smaller number of samples is sufficient when there exists prior knowledge about the distribution of the unknown vector, or when only partial recovery is needed. An information-theoretic lower bound with connections to free probability theory and an upp...

  17. [Correlative factor analysis of complications resulting from cement leakage after percutaneous kyphoplasty in treatment of osteoporotic vertebral body compression].

    Science.gov (United States)

    Shen, Yong; Ren, Hu; Zhang, Yingze; Zhi, Xinli; Ding, Wenyuan; Xu, Jiaxin; Yang, Dalong

    2010-01-01

    To explore the correlative factors affecting the complications resulting from cement leakage after percutaneous kyphoplasty (PKP) in the treatment of osteoporotic vertebral body compression fractures (OVCF). From February 2005 to October 2008, 71 patients with OVCF were treated by PKP and were retrospectively analyzed. There were 16 males and 55 females, and the average age was 71.5 years (range, 52-91 years). The average duration of disease was 5.7 months (range, 1-11 months). A total of 171 vertebra were involved in fracture including 19 cases of single vertebral fractures, 21 cases of double vertebral fractures, 20 cases of three vertebral fractures, and 11 cases of more than three vertebral fractures. All the treated vertebra were divided into acute (86 vertebra) or subacute (85 vertebra) state based on changes in MRI signal intensity. There was no radiculopathy or myelopathy. The average injected cement volume was 4.6 mL (range, 1.5-6.5 mL). The treatment efficacy was assessed by observing the change in anterior and middle vertebral column height, Cobb angle, visual analogue scale (VAS) and Oswestry functional score at preoperation, 3 days after operation and last follow-up. The patients were divided into cement leakage group and no cement leakage group. All the complications were recorded, and then the correlative factors affecting the complications were analyzed. All the cases had rapid and significant improvement in back pain following PKP. All patients were followed up for 14 months (range, 7-18 months). There was no cement extravasation resulting in radiculopathy or myelopathy. Four patients (5.63%) had lung-related complications. During the follow-up, 9 recurrence vertebral fractures were observed in 6 patients (8.45%). The anterior and middle vertebral column height, Cobb angle, VAS and Oswestry score were significantly improved when compared with preoperation (P 0.05) in preoperative Cobb angle, freshness of vertebral fracture, location of operative

  18. A Survey on Physical Factors and Compressed Breast Thickness in Voluntary Mammography Screening Using FFDM System in Malaysia: Preliminary Results

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung; Siti Kamariah Che Mohamad; Ellyda Muhamad Nordin

    2013-01-01

    This paper aims at presenting preliminary results of a survey on physical factors, namely tube potential (kV), tube current exposure time product (mAs) and compressed breast thickness (CBT) during voluntary mammography screening using Full-Field Digital Mammography (FFDM) System in Malaysia. Retrospective data were collected from 1128 FFDM images of 282 women from three major ethnic groups (Malay, Chinese and Indian) who underwent voluntary screening mammography at Breast Centre, International Islamic University Malaysia from January to March 2008. Results from the present study were then compared with results from the previous study on Screen-Film Mammography System (SFM) according to the ethnic group for both Cranio-caudal (CC) and Mediol-Lateral (MLO) views. We found that the mean kV for CC view for the three ethnic groups are Malay (28), Chinese (28) and Indian (28), and for MLO view are Malay (29), Chinese (28) and Indian (29). These values are higher than the kV for SFM which were Malay (26), Chinese (27) and Indian (26) for CC and Malay (26), Chinese (27) and Indian (26) for CC and MLO views respectively. The mean mAs for CC and MLO views for FFDM were lower compared to SFM systems. These values were Malay (104), Chinese (108) and Indian (91) for CC views and Malay (106), Chinese (105), and Indian (94) for MLO views for the FFDM system. The values for SFM system are for CC and MLO views were Malay (120), Chinese (106) and Indian (126), and Malay (166), Chinese (132), Indian (183) respectively. The median CBT for CC and MLO views increased by 27 % and 7 % respectively on the FFDM compared to the SFM system. In conclusion, the FFDM operates with higher kV, lower mAs, and higher CBT when compared with SFM system. Median CBT on CC and MLO view with FFDM system are 27 % and 7 % higher respectively compared to the SFM. We are currently collecting data on mean glandular dose with FFDM systems to assess how the change in local mammography practice influences this

  19. Reducing biases on H0 measurements using strong lensing and galaxy dynamics: results from the EAGLE simulation

    Science.gov (United States)

    Tagore, Amitpal S.; Barnes, David J.; Jackson, Neal; Kay, Scott T.; Schaller, Matthieu; Schaye, Joop; Theuns, Tom

    2018-03-01

    Cosmological parameter constraints from observations of time-delay lenses are becoming increasingly precise. However, there may be significant bias and scatter in these measurements due to, among other things, the so-called mass-sheet degeneracy. To estimate these uncertainties, we analyse strong lenses from the largest EAGLE hydrodynamical simulation. We apply a mass-sheet transformation to the radial density profiles of lenses, and by selecting lenses near isothermality, we find that the bias on H0 can be reduced to 5 per cent with an intrinsic scatter of 10 per cent, confirming previous results performed on a different simulation data set. We further investigate whether combining lensing observables with kinematic constraints helps to minimize this bias. We do not detect any significant dependence of the bias on lens model parameters or observational properties of the galaxy, but depending on the source-lens configuration, a bias may still exist. Cross lenses provide an accurate estimate of the Hubble constant, while fold (double) lenses tend to be biased low (high). With kinematic constraints, double lenses show bias and intrinsic scatter of 6 per cent and 10 per cent, respectively, while quad lenses show bias and intrinsic scatter of 0.5 per cent and 10 per cent, respectively. For lenses with a reduced χ2 > 1, a power-law dependence of the χ2 on the lens environment (number of nearby galaxies) is seen. Lastly, we model, in greater detail, the cases of two double lenses that are significantly biased. We are able to remove the bias, suggesting that the remaining biases could also be reduced by carefully taking into account additional sources of systematic uncertainty.

  20. Delamination of Compressed thin Layers at Corners

    DEFF Research Database (Denmark)

    Clausen, Johan; Jensen, Henrik Myhre; Sørensen, Kim Dalsten

    2008-01-01

    An analysis of delamination for a thin elastic film, attached to a substrate with a corner, is carried out. The film is in compression and the analysis is performed by combining results from fracture mechanics and the theory of thin shells. The results show a very strong dependency of the angle...

  1. Compressing Binary Decision Diagrams

    DEFF Research Database (Denmark)

    Hansen, Esben Rune; Satti, Srinivasa Rao; Tiedemann, Peter

    2008-01-01

    The paper introduces a new technique for compressing Binary Decision Diagrams in those cases where random access is not required. Using this technique, compression and decompression can be done in linear time in the size of the BDD and compression will in many cases reduce the size of the BDD to ......-2 bits per node. Empirical results for our compression technique are presented, including comparisons with previously introduced techniques, showing that the new technique dominate on all tested instances......The paper introduces a new technique for compressing Binary Decision Diagrams in those cases where random access is not required. Using this technique, compression and decompression can be done in linear time in the size of the BDD and compression will in many cases reduce the size of the BDD to 1...

  2. Compressing Binary Decision Diagrams

    DEFF Research Database (Denmark)

    Rune Hansen, Esben; Srinivasa Rao, S.; Tiedemann, Peter

    The paper introduces a new technique for compressing Binary Decision Diagrams in those cases where random access is not required. Using this technique, compression and decompression can be done in linear time in the size of the BDD and compression will in many cases reduce the size of the BDD to ......-2 bits per node. Empirical results for our compression technique are presented, including comparisons with previously introduced techniques, showing that the new technique dominate on all tested instances.......The paper introduces a new technique for compressing Binary Decision Diagrams in those cases where random access is not required. Using this technique, compression and decompression can be done in linear time in the size of the BDD and compression will in many cases reduce the size of the BDD to 1...

  3. Formation of Sheeting Joints as a Result of Compression Parallel to Convex Surfaces, With Examples from Yosemite National Park, California

    Science.gov (United States)

    Martel, S. J.

    2008-12-01

    The formation of sheeting joints has been an outstanding problem in geology. New observations and analyses indicate that sheeting joints develop in response to a near-surface tension induced by compressive stresses parallel to a convex slope (hypothesis 1) rather than by removal of overburden by erosion, as conventionally assumed (hypothesis 2). Opening mode displacements across the joints together with the absence of mineral precipitates within the joints mean that sheeting joints open in response to a near-surface tension normal to the surface rather than a pressurized fluid. Consideration of a plot of this tensile stress as a function of depth normal to the surface reveals that a true tension must arise in the shallow subsurface if the rate of that tensile stress change with depth is positive at the surface. Static equilibrium requires this rate (derivative) to equal P22 k2 + P33 k3 - ρ g cosβ, where k2 and k3 are the principal curvatures of the surface, P22 and P33 are the respective surface- parallel normal stresses along the principal curvatures, ρ is the material density, g is gravitational acceleration, and β is the slope. This derivative will be positive and sheeting joints can open if at least one principal curvature is sufficiently convex (negative) and the surface-parallel stresses are sufficiently compressive (negative). At several sites with sheeting joints (e.g., Yosemite National Park in California), the measured topographic curvatures and the measured surface-parallel stresses of about -10 MPa combine to meet this condition. In apparent violation of hypothesis 1, sheeting joints occur locally at the bottom of Tenaya Canyon, one of the deepest glaciated, U-shaped (concave) canyons in the park. The canyon-bottom sheeting joints only occur, however, where the canyon is convex downstream, a direction that nearly coincides with direction of the most compressive stress measured in the vicinity. The most compressive stress acting along the convex

  4. Mechanism and Simulation of Generating Pulsed Strong Magnetic Field

    Science.gov (United States)

    Yang, Xian-Jun; Wang, Shuai-Chuang; Deng, Ai-Dong; Gu, Zhuo-Wei; Luo, Hao

    2014-10-01

    A strong magnetic field (over 1000 T) was recently experimentally produced at the Academy of Engineering Physics in China. The theoretical methods, which include a simple model and MHD code, are discussed to investigate the physical mechanism and dynamics of generating the strong magnetic field. The analysis and simulation results show that nonlinear magnetic diffusion contributes less as compared to the linear magnetic diffusion. This indicates that the compressible hydrodynamic effect and solid imploding compression may have a large influence on strong magnetic field generation.

  5. EDF - 2015 full-year results: all targets reached, Strong operating performance in adverse market conditions, 2018 ambition reiterated

    International Nuclear Information System (INIS)

    2016-01-01

    A key player in energy transition, the EDF Group is an integrated electricity company, active in all areas of the business: generation, transmission, distribution, energy supply and trading, energy services. A global leader in low-carbon energies, the Group has developed a diversified generation mix based on nuclear power, hydropower, new renewable energies and thermal energy. The Group is involved in supplying energy and services to approximately 37.6 million customers, of which 27.8 million in France. The Group generated consolidated sales of Euro 75 billion in 2015, of which 47.2% outside of France. EDF is listed on the Paris Stock exchange. EDF achieved all its targets in 2015. The year was marked by strong operational performance, reflecting the significant efforts the teams made. With the end of the regulated Yellow and Green Tariffs, most clients turned to EDF. Nuclear output reached its highest level, since 2011 in France, and since 2005 in the United Kingdom. EDF is also continuing its significant development in renewable energy, with an additional 1 GW of net installed capacity. The transformation of EDF Group is essential in the unfavourable market conditions. EDF has embarked on this transformation, and is accelerating innovation to serve the energy transition

  6. Compression embedding

    Science.gov (United States)

    Sandford, M.T. II; Handel, T.G.; Bradley, J.N.

    1998-07-07

    A method and apparatus for embedding auxiliary information into the digital representation of host data created by a lossy compression technique and a method and apparatus for constructing auxiliary data from the correspondence between values in a digital key-pair table with integer index values existing in a representation of host data created by a lossy compression technique are disclosed. The methods apply to data compressed with algorithms based on series expansion, quantization to a finite number of symbols, and entropy coding. Lossy compression methods represent the original data as ordered sequences of blocks containing integer indices having redundancy and uncertainty of value by one unit, allowing indices which are adjacent in value to be manipulated to encode auxiliary data. Also included is a method to improve the efficiency of lossy compression algorithms by embedding white noise into the integer indices. Lossy compression methods use loss-less compression to reduce to the final size the intermediate representation as indices. The efficiency of the loss-less compression, known also as entropy coding compression, is increased by manipulating the indices at the intermediate stage. Manipulation of the intermediate representation improves lossy compression performance by 1 to 10%. 21 figs.

  7. Nonlinear excitation of electron cyclotron waves by a monochromatic strong microwave: computer simulation analysis of the MINIX results

    International Nuclear Information System (INIS)

    Matsumoto, H.; Kimura, T.

    1986-01-01

    Triggered by the experimental results of the MINIX, a computer simulation study was initiated on the nonlinear excitation of electrostatic electron cyclotron waves by a monochromatic electromagnetic wave such as the transmitted microwave in the MINIX. The model used assumes that both of the excited waves and exciting (pumping) electromagnetic wave as well as the idler electromagnetic wave propagate in the direction perpendicular to the external magnetic field. The simulation code used for this study was the one-and-two-half dimensional electromagnetic particle code named KEMPO. The simulation result shows the high power electromagnetic wave produces both the backscattered electromagnetic wave and electrostatic electron cyclotron waves as a result of nonlinear parametric instability. Detailed nonlinear microphysics related to the wave excitation is discussed in terms of the nonlinear wave-wave couplings and associated ponderomotive force produced by the high power electromagnetic waves. 2 references, 4 figures

  8. Procalcitonin is a strong predictor of urine culture results in patients with obstructing ureteral stones: A prospective, pilot study

    Directory of Open Access Journals (Sweden)

    Dimitri Papagiannopoulos

    2016-01-01

    Conclusions: This proof-of-concept pilot study gives encouraging results, in that PCT was a good predictor of positive cultures (P = 0.02, AUC 0.812. Given, the small sample size, one cannot directly compare PCT to other markers of infection. However, PCT shows promise in this arena and warrants future investigation.

  9. Cascaded quadratic soliton compression at 800 nm

    DEFF Research Database (Denmark)

    Bache, Morten; Bang, Ole; Moses, Jeffrey

    2007-01-01

    We study soliton compression in quadratic nonlinear materials at 800 nm, where group-velocity mismatch dominates. We develop a nonlocal theory showing that efficient compression depends strongly on characteristic nonlocal time scales related to pulse dispersion.......We study soliton compression in quadratic nonlinear materials at 800 nm, where group-velocity mismatch dominates. We develop a nonlocal theory showing that efficient compression depends strongly on characteristic nonlocal time scales related to pulse dispersion....

  10. Intense Shock Waves and Strongly Coupled Plasmas

    Science.gov (United States)

    Fortov, Vladimir

    2005-07-01

    The report presents the recent results of experimental investigations of equations of state, compositions, thermodynamical and transport properties, electrical conductivity and opacity of strongly coupled plasmas generated by intense shock and rarefaction waves. The experimental methods for generation of high energy densities in matter, drivers for shock waves and fast diagnostic tools are discussed. Application of intense shock waves to solid and porous targets generates nonideal plasmas in megabar-gigabar pressure range. Compression of plasma by a series of reverberating shock waves allows us to decrease irreversible heating effects. To increase the irreversibility effects and to generate high temperature plasma states the experiments on shock compression of porous samples (fine metal powder, aerogels) were performed. The adiabatic expansion of matter initially compressed by intense shocks up to megabars allows investigating the intermediate region between the solid and vapor phase of nonideal plasmas, including the metal-insulator transition phase and the high temperature saturation curve with critical points of metals. The shock-wave-induced non-equilibrium phenomena at fast melting, spallation and adiabatic condensation are analyzed in the framework of the interspinodal decomposition model. The spall strength of single and polycrystal metals at extremely fast deformation produced by fast shock waves is discussed. The ``pressure ionization'' phenomena in hydrogen, helium, argon, xenon, krypton, neon, iodine, silica, sulfur, fullerenes, and some metals are analyzed on the base of multiple shock compression experiments. For some simple metals (Li, Na, Ca) the effect of ``dielectrization'' as a result of multiple shock compression are discussed.

  11. Twofold reduction of phosphofructokinase activity in Lactococcus lactis results in strong decreases in growth rate and in glycolytic flux

    DEFF Research Database (Denmark)

    Andersen, Heidi Winterberg; Solem, Christian; Hammer, Karin

    2001-01-01

    reduced. Surprisingly, the mutants still showed homolactic fermentation, which indicated that the limitation was different from standard glucose-limited conditions, One explanation could be that the reduced activity of phosphofructokinase resulted in the accumulation of sugar-phosphates. Indeed, when one...... kinase and lactate dehydrogenase remained closer to the wild-type level. In defined medium supplemented with glucose, the growth rate of the mutants was reduced to 57 to 70% of wild-type levels and the glycolytic flux was reduced to 62 to 76% of wild-type levels. In complex medium growth was even further...... of the mutants was starved for glucose in glucose-limited chemostat, the growth rate could gradually be increased to 195% of the growth fate observed in glucose-saturated batch culture, suggesting that phosphofructokinase does affect the concentration of upstream metabolites. The pools of glucose-6- phosphate...

  12. Low-frequency ac electroporation shows strong frequency dependence and yields comparable transfection results to dc electroporation.

    Science.gov (United States)

    Zhan, Yihong; Cao, Zhenning; Bao, Ning; Li, Jianbo; Wang, Jun; Geng, Tao; Lin, Hao; Lu, Chang

    2012-06-28

    Conventional electroporation has been conducted by employing short direct current (dc) pulses for delivery of macromolecules such as DNA into cells. The use of alternating current (ac) field for electroporation has mostly been explored in the frequency range of 10kHz-1MHz. Based on Schwan equation, it was thought that with low ac frequencies (10Hz-10kHz), the transmembrane potential does not vary with the frequency. In this report, we utilized a flow-through electroporation technique that employed continuous 10Hz-10kHz ac field (based on either sine waves or square waves) for electroporation of cells with defined duration and intensity. Our results reveal that electropermeabilization becomes weaker with increased frequency in this range. In contrast, transfection efficiency with DNA reaches its maximum at medium frequencies (100-1000Hz) in the range. We postulate that the relationship between the transfection efficiency and the ac frequency is determined by combined effects from electrophoretic movement of DNA in the ac field, dependence of the DNA/membrane interaction on the ac frequency, and variation of transfection under different electropermeabilization intensities. The fact that ac electroporation in this frequency range yields high efficiency for transfection (up to ~71% for Chinese hamster ovary cells) and permeabilization suggests its potential for gene delivery. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Fluid pressure, sediment compressibility, and secular and transient strain in subduction prisms: Results from ODP CORK borehole hydrologic observatories

    Science.gov (United States)

    Davis, E. E.; Becker, K.

    2005-12-01

    Instruments for long-term hydrogeological monitoring in Ocean Drilling Program boreholes have been installed in five subduction zone settings, including Cascadia, Barbados, Mariana, Costa Rica, and Nankai. Pressure records reveal a wide range of average formation states that are consistent with formation permeability and proximity to sources of formation fluid. For example, near-hydrostatic pressures (excess pore-pressure ratio λ* ~ 0) are observed in the silty parts of the Nankai accretionary prism and in the upper oceanic crust beneath the Costa Rica prism, where well-drained conditions are inferred to be present, and elevated pressures (λ* up to 0.5) have been recorded in finer-grained sedimentary sections near the toe of prisms (e.g., at the level of the decollement in the fine-grained part of the Barbados accretionary prism). In no instances have high pressures (approaching lithostatic, λ* = 1) been observed, although operational difficulties have thus far precluded installations in underthrust sediment sequences where the highest average pressures are expected to be maintained. Records often reveal non-steady behavior, with variations occurring over a broad frequency range. Tidal-frequency variations present in all records are the consequence of oceanographic loading at the seafloor. The amplitude of these signals provide constraints on formation compressibility. Estimated values vary with depth and consolidation state, and range from 5 x 10-9 to 3.5 x 10-10 Pa-1. Once these signals are removed, other transients can be observed, including ones correlated with both seismic and aseismic deformation. Secular strain has been seen in hydrologically isolated parts of the formations at several sites. At the Mariana forearc site, seismic-frequency pressure variations and persistent positive pressure changes were observed at the time of two large (Mb ~ 7.0) deep (~ 70 km) earthquakes located roughly 200 km away; these signals are inferred to reflect local formation

  14. Stress Drop as a Result of Splitting, Brittle and Transitional Faulting of Rock Samples in Uniaxial and Triaxial Compression Tests

    Directory of Open Access Journals (Sweden)

    Cieślik Jerzy

    2015-03-01

    Full Text Available Rock samples can behave brittle, transitional or ductile depending on test pressure, rate of loading and temperature. Axial stiffness and its changes, relative and absolute dilatancy, yield, and fracture thresholds, residual strength are strongly pressure dependent. In this paper the stress drop as an effect of rock sample strength loss due to failure was analyzed. Uniaxial and triaxial experiments on three types of rock were performed to investigate the stress drop phenomenon. The paper first introduces short background on rock behavior and parameters defining a failure process under uniaxial and triaxial loading conditions. Stress drop data collected with experiments are analyzed and its pressure dependence phenomenon is described. Two methods for evaluation of stress drop value are presented.

  15. Saturation of superstorms and finite compressibility of the magnetosphere: Results of the magnetogram inversion technique and global PPMLR-MHD model

    Science.gov (United States)

    Mishin, V. V.; Mishin, V. M.; Karavaev, Yu.; Han, J. P.; Wang, C.

    2016-07-01

    We report on novel features of the saturation process of the polar cap magnetic flux and Poynting flux into the magnetosphere from the solar wind during three superstorms. In addition to the well-known effect of the interplanetary electric (Esw) and southward magnetic (interplanetary magnetic field (IMF) Bz) fields, we found that the saturation depends also on the solar wind ram pressure Pd. By means of the magnetogram inversion technique and a global MHD numerical model Piecewise Parabolic Method with a Lagrangian Remap, we explore the dependence of the magnetopause standoff distance on ram pressure and the southward IMF. Unlike earlier studies, in the considered superstorms both Pd and Bz achieve extreme values. As a result, we show that the compression rate of the dayside magnetosphere decreases with increasing Pd and the southward Bz, approaching very small values for extreme Pd ≥ 15 nPa and Bz ≤ -40 nT. This dependence suggests that finite compressibility of the magnetosphere controls saturation of superstorms.

  16. Simple Formulas and Results for Buckling-Resistance and Stiffness Design of Compression-Loaded Laminated-Composite Cylinders

    Science.gov (United States)

    Nemeth, Michael P.; Mikulas, Martin M., Jr.

    2009-01-01

    Simple formulas for the buckling stress of homogeneous, specially orthotropic, laminated-composite cylinders are presented. The formulas are obtained by using nondimensional parameters and equations that facilitate general validation, and are validated against the exact solution for a wide range of cylinder geometries and laminate constructions. Results are presented that establish the ranges of the nondimensional parameters and coefficients used. General results, given in terms of the nondimensional parameters, are presented that encompass a wide range of geometries and laminate constructions. These general results also illustrate a wide spectrum of behavioral trends. Design-oriented results are also presented that provide a simple, clear indication of laminate composition on critical stress, critical strain, and axial stiffness. An example is provided to demonstrate the application of these results to thin-walled column designs.

  17. Compressed Counting Meets Compressed Sensing

    OpenAIRE

    Li, Ping; Zhang, Cun-Hui; Zhang, Tong

    2013-01-01

    Compressed sensing (sparse signal recovery) has been a popular and important research topic in recent years. By observing that natural signals are often nonnegative, we propose a new framework for nonnegative signal recovery using Compressed Counting (CC). CC is a technique built on maximally-skewed p-stable random projections originally developed for data stream computations. Our recovery procedure is computationally very efficient in that it requires only one linear scan of the coordinates....

  18. Optical pulse compression

    International Nuclear Information System (INIS)

    Glass, A.J.

    1975-01-01

    The interest in using large lasers to achieve a very short and intense pulse for generating fusion plasma has provided a strong impetus to reexamine the possibilities of optical pulse compression at high energy. Pulse compression allows one to generate pulses of long duration (minimizing damage problems) and subsequently compress optical pulses to achieve the short pulse duration required for specific applications. The ideal device for carrying out this program has not been developed. Of the two approaches considered, the Gires--Tournois approach is limited by the fact that the bandwidth and compression are intimately related, so that the group delay dispersion times the square of the bandwidth is about unity for all simple Gires--Tournois interferometers. The Treacy grating pair does not suffer from this limitation, but is inefficient because diffraction generally occurs in several orders and is limited by the problem of optical damage to the grating surfaces themselves. Nonlinear and parametric processes were explored. Some pulse compression was achieved by these techniques; however, they are generally difficult to control and are not very efficient. (U.S.)

  19. Effect of the static compressive load on vibration propagation in multistory buildings and resulting heavyweight floor impact sounds.

    Science.gov (United States)

    Kwak, Yunsang; Lee, Sinyeob; Park, Jeongwon; Hwang, Dukyoung; Jeon, Jin Yong; Park, Junhong

    2017-07-01

    Experiments were performed to identify the mechanism of heavyweight floor impact sound transmission through floors in a high-rise apartment building. Vibration and sound levels on each floor of the multistory building were measured. The vibration generated at a given floor was transferred to multiple adjacent floors with decreasing amplitudes proportional to the distance from the excited floor. This vibration transfer introduced significant sound transmissions. The structural static load varied depending on the floor location due to differences in the weight of the structure above the floor, especially for wall construction buildings. The static load at the wall of the bottom floor was the largest among the different floors. The influence of this static load on the impact sound generation was investigated through tests in the actual building and the scale model, respectively. The results were numerically analyzed using the spectral element method. With the increasing static load, the resonance frequencies of the floor increased due to the change in the vibration modes of the structure. The modulated sound generation from the floor vibrations transmitted to multiple layers with larger magnitudes due to this static load.

  20. Compressive beamforming

    DEFF Research Database (Denmark)

    Xenaki, Angeliki; Mosegaard, Klaus

    2014-01-01

    Sound source localization with sensor arrays involves the estimation of the direction-of-arrival (DOA) from a limited number of observations. Compressive sensing (CS) solves such underdetermined problems achieving sparsity, thus improved resolution, and can be solved efficiently with convex...

  1. Model predictions of the results of interferometric observations for stars under conditions of strong gravitational scattering by black holes and wormholes

    International Nuclear Information System (INIS)

    Shatskiy, A. A.; Kovalev, Yu. Yu.; Novikov, I. D.

    2015-01-01

    The characteristic and distinctive features of the visibility amplitude of interferometric observations for compact objects like stars in the immediate vicinity of the central black hole in our Galaxy are considered. These features are associated with the specifics of strong gravitational scattering of point sources by black holes, wormholes, or black-white holes. The revealed features will help to determine the most important topological characteristics of the central object in our Galaxy: whether this object possesses the properties of only a black hole or also has characteristics unique to wormholes or black-white holes. These studies can be used to interpret the results of optical, infrared, and radio interferometric observations

  2. Model predictions of the results of interferometric observations for stars under conditions of strong gravitational scattering by black holes and wormholes

    Energy Technology Data Exchange (ETDEWEB)

    Shatskiy, A. A., E-mail: shatskiy@asc.rssi.ru; Kovalev, Yu. Yu.; Novikov, I. D. [Russian Academy of Sciences, Astro Space Center, Lebedev Physical Institute (Russian Federation)

    2015-05-15

    The characteristic and distinctive features of the visibility amplitude of interferometric observations for compact objects like stars in the immediate vicinity of the central black hole in our Galaxy are considered. These features are associated with the specifics of strong gravitational scattering of point sources by black holes, wormholes, or black-white holes. The revealed features will help to determine the most important topological characteristics of the central object in our Galaxy: whether this object possesses the properties of only a black hole or also has characteristics unique to wormholes or black-white holes. These studies can be used to interpret the results of optical, infrared, and radio interferometric observations.

  3. Clinical outcome after the use of a new craniocaudal expandable implant for vertebral compression fracture treatment: one year results from a prospective multicentric study.

    Science.gov (United States)

    Noriega, David; Krüger, Antonio; Ardura, Francisco; Hansen-Algenstaedt, Nils; Hassel, Frank; Barreau, Xavier; Beyerlein, Jörg

    2015-01-01

    The purpose of this prospective multicentric observational study was to confirm the safety and clinical performance of a craniocaudal expandable implant used in combination with high viscosity PMMA bone cement for the treatment of vertebral compression fractures. Thirty-nine VCFs in 32 patients were treated using the SpineJack minimally invasive surgery protocol. Outcome was determined by using the Visual Analogue Scale for measuring pain, the Oswestry Disability Index for scoring functional capacity, and the self-reporting European Quality of Life scores for the quality of life. Safety was evaluated by reporting all adverse events. The occurrence of cement leakages was assessed by either radiographs or CT scan or both. Statistically significant improvements were found regarding pain, function, and quality of life. The global pain score reduction at 1 year was 80.9% compared to the preoperative situation and the result of the Oswestry Disability Index showed a decrease from 65.0% at baseline to 10.5% at 12 months postoperatively. The cement leakage rate was 30.8%. No device- or surgery-related complications were found. This observational study demonstrates promising and persistent results consisting of immediate and sustained pain relief and durable clinical improvement after the procedure and throughout the 1-year follow-up period.

  4. Clinical Outcome after the Use of a New Craniocaudal Expandable Implant for Vertebral Compression Fracture Treatment: One Year Results from a Prospective Multicentric Study

    Directory of Open Access Journals (Sweden)

    David Noriega

    2015-01-01

    Full Text Available The purpose of this prospective multicentric observational study was to confirm the safety and clinical performance of a craniocaudal expandable implant used in combination with high viscosity PMMA bone cement for the treatment of vertebral compression fractures. Thirty-nine VCFs in 32 patients were treated using the SpineJack minimally invasive surgery protocol. Outcome was determined by using the Visual Analogue Scale for measuring pain, the Oswestry Disability Index for scoring functional capacity, and the self-reporting European Quality of Life scores for the quality of life. Safety was evaluated by reporting all adverse events. The occurrence of cement leakages was assessed by either radiographs or CT scan or both. Statistically significant improvements were found regarding pain, function, and quality of life. The global pain score reduction at 1 year was 80.9% compared to the preoperative situation and the result of the Oswestry Disability Index showed a decrease from 65.0% at baseline to 10.5% at 12 months postoperatively. The cement leakage rate was 30.8%. No device- or surgery-related complications were found. This observational study demonstrates promising and persistent results consisting of immediate and sustained pain relief and durable clinical improvement after the procedure and throughout the 1-year follow-up period.

  5. Speech Compression

    Directory of Open Access Journals (Sweden)

    Jerry D. Gibson

    2016-06-01

    Full Text Available Speech compression is a key technology underlying digital cellular communications, VoIP, voicemail, and voice response systems. We trace the evolution of speech coding based on the linear prediction model, highlight the key milestones in speech coding, and outline the structures of the most important speech coding standards. Current challenges, future research directions, fundamental limits on performance, and the critical open problem of speech coding for emergency first responders are all discussed.

  6. Mammographic compression in Asian women

    Science.gov (United States)

    Lau, Susie; Abdul Aziz, Yang Faridah; Ng, Kwan Hoong

    2017-01-01

    Objectives To investigate: (1) the variability of mammographic compression parameters amongst Asian women; and (2) the effects of reducing compression force on image quality and mean glandular dose (MGD) in Asian women based on phantom study. Methods We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35–80 years who underwent screening or diagnostic mammography between Jan 2012 and Dec 2014 at our center. The mammograms were processed using a volumetric breast density (VBD) measurement software (Volpara) to assess compression force, compression pressure, compressed breast thickness (CBT), breast volume, VBD and MGD against breast contact area. The effects of reducing compression force on image quality and MGD were also evaluated based on measurement obtained from 105 Asian women, as well as using the RMI156 Mammographic Accreditation Phantom and polymethyl methacrylate (PMMA) slabs. Results Compression force, compression pressure, CBT, breast volume, VBD and MGD correlated significantly with breast contact area (p0.05). Conclusions Force-standardized protocol led to widely variable compression parameters in Asian women. Based on phantom study, it is feasible to reduce compression force up to 32.5% with minimal effects on image quality and MGD. PMID:28419125

  7. Combined pretreatment with hot compressed water and wet disk milling opened up oil palm biomass structure resulting in enhanced enzymatic digestibility.

    Science.gov (United States)

    Zakaria, Mohd Rafein; Hirata, Satoshi; Fujimoto, Shinji; Hassan, Mohd Ali

    2015-10-01

    Combined pretreatment with hot compressed water and wet disk milling was performed with the aim to reduce the natural recalcitrance of oil palm biomass by opening its structure and provide maximal access to cellulase attack. Oil palm empty fruit bunch and oil palm frond fiber were first hydrothermally pretreated at 150-190° C and 10-240 min. Further treatment with wet disk milling resulted in nanofibrillation of fiber which caused the loosening of the tight biomass structure, thus increasing the subsequent enzymatic conversion of cellulose to glucose. The effectiveness of the combined pretreatments was evaluated by chemical composition changes, power consumption, morphological alterations by SEM and the enzymatic digestibility of treated samples. At optimal pretreatment process, approximately 88.5% and 100.0% of total sugar yields were obtained from oil palm empty fruit bunch and oil palm frond fiber samples, which only consumed about 15.1 and 23.5 MJ/kg of biomass, respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Microbiological test results of the environmental control and life support systems vapors compression distillation subsystem recycle tank components following various pretreatment protocols

    Science.gov (United States)

    Huff, Tim

    1993-01-01

    Microbiological samples were collected from the recycle tank of the vapor compression distillation (VCD) subsystem of the water recovery test at NASA MSFC following a 68-day run. The recycle tank collects rejected urine brine that was pretreated with a commercially available oxidant (Oxone) and sulfuric acid and pumps it back to the processing component of the VCD. Samples collected included a water sample and two swab samples, one from the particulate filter surface and a second from material floating on the surface of the water. No bacteria were recovered from the water sample. Both swab samples contained a spore-forming bacterium, Bacillus insolitus. A filamentous fungus was isolated from the floating material. Approximately 1 month after the pretreatment chemicals were changed to sodium hypochlorite and sulfuric acid, a swab of the particulate filter was again analyzed for microbial content. One fungus was isolated, and spore-forming bacteria were observed. These results indicate the inability of these pretreatments to inhibit surface attachment. The implications of the presence of these organisms are discussed.

  9. Balloon-assisted percutaneous vertebroplasty in patients with osteoporotic compression fractures - first results; Ballonassistierte perkutane Vertebroplastie bei Patienten mit osteoporotischen Wirbelkoerperkompressionsfrakturen - erste Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Schulte, B.U.; Trompeter, M.; Remy, C.; Reimer, P. [Zentralinstitut fuer Bildgebende Diagnostik, Staedtisches Klinikum Karlsruhe (Germany); Bruecher, D. [Abt. fuer Unfallchirurgie, Staedtisches Klinikum Karlsruhe (Germany)

    2006-02-15

    Purpose: To determine the feasibility, efficacy and safety of balloon-assisted percutaneous vertebroplasty (BA-VP) in patients with osteoporotic vertebral compression fractures (VCFs). Materials and Methods: In 47 patients (29 women, 18 men; mean age: 70 years and 4 months) with severe VCFs, 66 BA-VPs were performed via a unipedicular access. After initial puncture (under combined fluoroscopy and CT guidance) of the vertebral body (VB), the needle was retraced by 1.5 cm, and a 12-mm Fogarty balloon catheter was introduced and inflated using 2-4 ml diluted contrast media (CM). After the subsequent removal of the catheter and repositioning of the needle, vertebroplasty was performed. Results: The mean volume of PMMA injected was 4.4 ml (2.5-7.2 ml). Pain reduction (measured by the Visual Analogue Scale) was achieved in 95% of the patients, dropping from on average 8.0 preinterventionally to 2.2 after a mean follow-up of 8 months. A reduction of the pain relieving medication was achieved in 68% of the cases and patient activity improved markedly. No severe or clinically relevant complications were observed. Cement leakage occurred by filling of epidural and paravertebral veins in 9.1 and 6.1% of the cases, respectively. Leakage into the paravertebral soft tissues was seen in 3.0% of the patients and to the adjacent disc space in 10.6% of the cases. (orig.)

  10. results

    Directory of Open Access Journals (Sweden)

    Salabura Piotr

    2017-01-01

    Full Text Available HADES experiment at GSI is the only high precision experiment probing nuclear matter in the beam energy range of a few AGeV. Pion, proton and ion beams are used to study rare dielectron and strangeness probes to diagnose properties of strongly interacting matter in this energy regime. Selected results from p + A and A + A collisions are presented and discussed.

  11. Artificial Neural Network Model for Predicting Compressive

    Directory of Open Access Journals (Sweden)

    Salim T. Yousif

    2013-05-01

    Full Text Available   Compressive strength of concrete is a commonly used criterion in evaluating concrete. Although testing of the compressive strength of concrete specimens is done routinely, it is performed on the 28th day after concrete placement. Therefore, strength estimation of concrete at early time is highly desirable. This study presents the effort in applying neural network-based system identification techniques to predict the compressive strength of concrete based on concrete mix proportions, maximum aggregate size (MAS, and slump of fresh concrete. Back-propagation neural networks model is successively developed, trained, and tested using actual data sets of concrete mix proportions gathered from literature.    The test of the model by un-used data within the range of input parameters shows that the maximum absolute error for model is about 20% and 88% of the output results has absolute errors less than 10%. The parametric study shows that water/cement ratio (w/c is the most significant factor  affecting the output of the model.     The results showed that neural networks has strong potential as a feasible tool for predicting compressive strength of concrete.

  12. Novel adhesive glove device (AGD) for active compression-decompression (ACD) CPR results in improved carotid blood flow and coronary perfusion pressure in piglet model of cardiac arrest.

    Science.gov (United States)

    Udassi, Jai P; Udassi, Sharda; Shih, Andre; Lamb, Melissa A; Porvasnik, Stacy L; Zaritsky, Arno L; Haque, Ikram U

    2012-06-01

    ACD-CPR improves coronary and cerebral perfusion. We developed an adhesive glove device (AGD) and hypothesized that ACD-CPR using an AGD provides better chest decompression resulting in improved carotid blood flow as compared to standard (S)-CPR. Prospective, randomized and controlled animal study. Sixteen anesthetized and ventilated piglets were randomized after 3 min of untreated VF to receive either S-CPR or AGD-ACD-CPR by a PALS certified single rescuer with compressions of 100 min(-1) and C:V ratio of 30:2. AGD consisted of a modified leather glove exposing the fingers and thumb. A wide Velcro patch was sewn to the palmer aspect of the glove and the counter Velcro patch was adhered to the pig's chest wall. Carotid blood flow was measured using ultrasound. Data (mean±SD) was analyzed using one way ANOVA and unpaired t-test; p-value ≤ 0.05 was considered statistically significant. Right atrial pressure (mmHg) during the decompression phase was lower during AGD-ACD-CPR (-3.32±2.0) when compared to S-CPR (0.86±1.8, p=0.0007). Mean carotid blood flow was 53.2±27.1 (% of baseline blood flow in ml/min) in AGD vs. 19.1±12.5% in S-CPR, p=0.006. Coronary perfusion pressure (CPP, mmHg) was 29.9±5.8 in AGD vs. 22.7±6.9 in S-CPR, p=0.04. There was no significant difference in time to ROSC and number of epinephrine doses. Active chest decompression during CPR using this simple and inexpensive adhesive glove device resulted in significantly better carotid blood flow during the first 2 min of CPR. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. Accurate nonlocal theory for cascaded quadratic soliton compression

    DEFF Research Database (Denmark)

    Bache, Morten; Bang, Ole; Moses, Jeffrey

    2007-01-01

    We study soliton compression in bulk quadratic nonlinear materials at 800 nm, where group-velocity mismatch dominates. We develop a nonlocal theory showing that efficient compression depends strongly on characteristic nonlocal time scales related to pulse dispersion....

  14. Images compression in nuclear medicine

    International Nuclear Information System (INIS)

    Rebelo, M.S.; Furuie, S.S.; Moura, L.

    1992-01-01

    The performance of two methods for images compression in nuclear medicine was evaluated. The LZW precise, and Cosine Transformed, approximate, methods were analyzed. The results were obtained, showing that the utilization of approximated method produced images with an agreeable quality for visual analysis and compression rates, considerably high than precise method. (C.G.C.)

  15. Compression of Infrared images

    DEFF Research Database (Denmark)

    Mantel, Claire; Forchhammer, Søren

    2017-01-01

    This paper investigates the compression of infrared images with three codecs: JPEG2000, JPEG-XT and HEVC. Results are evaluated in terms of SNR, Mean Relative Squared Error (MRSE) and the HDR-VDP2 quality metric. JPEG2000 and HEVC perform fairy similar and better than JPEG-XT. JPEG2000 performs...

  16. Compressing Data Cube in Parallel OLAP Systems

    Directory of Open Access Journals (Sweden)

    Frank Dehne

    2007-03-01

    Full Text Available This paper proposes an efficient algorithm to compress the cubes in the progress of the parallel data cube generation. This low overhead compression mechanism provides block-by-block and record-by-record compression by using tuple difference coding techniques, thereby maximizing the compression ratio and minimizing the decompression penalty at run-time. The experimental results demonstrate that the typical compression ratio is about 30:1 without sacrificing running time. This paper also demonstrates that the compression method is suitable for Hilbert Space Filling Curve, a mechanism widely used in multi-dimensional indexing.

  17. Nonlinear Frequency Compression

    Science.gov (United States)

    Scollie, Susan; Glista, Danielle; Seelisch, Andreas

    2013-01-01

    Frequency lowering technologies offer an alternative amplification solution for severe to profound high frequency hearing losses. While frequency lowering technologies may improve audibility of high frequency sounds, the very nature of this processing can affect the perceived sound quality. This article reports the results from two studies that investigated the impact of a nonlinear frequency compression (NFC) algorithm on perceived sound quality. In the first study, the cutoff frequency and compression ratio parameters of the NFC algorithm were varied, and their effect on the speech quality was measured subjectively with 12 normal hearing adults, 12 normal hearing children, 13 hearing impaired adults, and 9 hearing impaired children. In the second study, 12 normal hearing and 8 hearing impaired adult listeners rated the quality of speech in quiet, speech in noise, and music after processing with a different set of NFC parameters. Results showed that the cutoff frequency parameter had more impact on sound quality ratings than the compression ratio, and that the hearing impaired adults were more tolerant to increased frequency compression than normal hearing adults. No statistically significant differences were found in the sound quality ratings of speech-in-noise and music stimuli processed through various NFC settings by hearing impaired listeners. These findings suggest that there may be an acceptable range of NFC settings for hearing impaired individuals where sound quality is not adversely affected. These results may assist an Audiologist in clinical NFC hearing aid fittings for achieving a balance between high frequency audibility and sound quality. PMID:23539261

  18. Non-Uniform Compressive Strength of Debonded Sandwich Panels

    DEFF Research Database (Denmark)

    Nøkkentved, Alexandros; Lundsgaard-Larsen, Christian; Berggreen, Carl Christian

    2005-01-01

    debonds show a considerable strength reduction with increasing debond diameter, with failure mechanisms varying between fast debond propagation and wrinkling-introduced face compression failure for large and small debonds, respectively. Residual strength predictions are based on intact panel testing...... of applying a controlled non-uniform compressive load to the test panels requires a strong focus on the development of a suitable testrig. This is done by the extensive use of product development methods. The experimental results based on full-scale testing of 10 GFRP/foam core panels with prefabricated...

  19. Clinical Outcome after the Use of a New Craniocaudal Expandable Implant for Vertebral Compression Fracture Treatment: One Year Results from a Prospective Multicentric Study

    OpenAIRE

    Noriega, David; Kr?ger, Antonio; Ardura, Francisco; Hansen-Algenstaedt, Nils; Hassel, Frank; Barreau, Xavier; Beyerlein, J?rg

    2015-01-01

    The purpose of this prospective multicentric observational study was to confirm the safety and clinical performance of a craniocaudal expandable implant used in combination with high viscosity PMMA bone cement for the treatment of vertebral compression fractures. Thirty-nine VCFs in 32 patients were treated using the SpineJack minimally invasive surgery protocol. Outcome was determined by using the Visual Analogue Scale for measuring pain, the Oswestry Disability Index for scoring functional ...

  20. Application specific compression : final report.

    Energy Technology Data Exchange (ETDEWEB)

    Melgaard, David Kennett; Byrne, Raymond Harry; Myers, Daniel S.; Harrison, Carol D.; Lee, David S.; Lewis, Phillip J.; Carlson, Jeffrey J.

    2008-12-01

    With the continuing development of more capable data gathering sensors, comes an increased demand on the bandwidth for transmitting larger quantities of data. To help counteract that trend, a study was undertaken to determine appropriate lossy data compression strategies for minimizing their impact on target detection and characterization. The survey of current compression techniques led us to the conclusion that wavelet compression was well suited for this purpose. Wavelet analysis essentially applies a low-pass and high-pass filter to the data, converting the data into the related coefficients that maintain spatial information as well as frequency information. Wavelet compression is achieved by zeroing the coefficients that pertain to the noise in the signal, i.e. the high frequency, low amplitude portion. This approach is well suited for our goal because it reduces the noise in the signal with only minimal impact on the larger, lower frequency target signatures. The resulting coefficients can then be encoded using lossless techniques with higher compression levels because of the lower entropy and significant number of zeros. No significant signal degradation or difficulties in target characterization or detection were observed or measured when wavelet compression was applied to simulated and real data, even when over 80% of the coefficients were zeroed. While the exact level of compression will be data set dependent, for the data sets we studied, compression factors over 10 were found to be satisfactory where conventional lossless techniques achieved levels of less than 3.

  1. Compression limits in cascaded quadratic soliton compression

    DEFF Research Database (Denmark)

    Bache, Morten; Bang, Ole; Krolikowski, Wieslaw

    2008-01-01

    Cascaded quadratic soliton compressors generate under optimal conditions few-cycle pulses. Using theory and numerical simulations in a nonlinear crystal suitable for high-energy pulse compression, we address the limits to the compression quality and efficiency.......Cascaded quadratic soliton compressors generate under optimal conditions few-cycle pulses. Using theory and numerical simulations in a nonlinear crystal suitable for high-energy pulse compression, we address the limits to the compression quality and efficiency....

  2. Relationship between the edgewise compression strength of ...

    African Journals Online (AJOL)

    The results of this study were used to determine the linear regression constants in the Maltenfort model by correlating the measured board edgewise compression strength (ECT) with the predicted strength, using the paper components' compression strengths, measured with the short-span compression test (SCT) and the ...

  3. H.264/AVC Video Compression on Smartphones

    Science.gov (United States)

    Sharabayko, M. P.; Markov, N. G.

    2017-01-01

    In this paper, we studied the usage of H.264/AVC video compression tools by the flagship smartphones. The results show that only a subset of tools is used, meaning that there is still a potential to achieve higher compression efficiency within the H.264/AVC standard, but the most advanced smartphones are already reaching the compression efficiency limit of H.264/AVC.

  4. Considerations and Algorithms for Compression of Sets

    DEFF Research Database (Denmark)

    Larsson, Jesper

    We consider compression of unordered sets of distinct elements. After a discus- sion of the general problem, we focus on compressing sets of fixed-length bitstrings in the presence of statistical information. We survey techniques from previous work, suggesting some adjustments, and propose a novel...... compression algorithm that allows transparent incorporation of various estimates for probability distribution. Our experimental results allow the conclusion that set compression can benefit from incorporat- ing statistics, using our method or variants of previously known techniques....

  5. Tapentadol prolonged release versus strong opioids for severe, chronic low back pain: results of an open-label, phase 3b study.

    Science.gov (United States)

    Gálvez, Rafael; Schäfer, Michael; Hans, Guy; Falke, Dietmar; Steigerwald, Ilona

    2013-03-01

    This open-label, phase 3b study evaluated the effectiveness and tolerability of oral tapentadol prolonged release (PR; 50-250 mg twice daily [b.i.d.]) for managing severe, chronic low back pain in patients responding to World Health Organization (WHO) step III opioids but tolerating treatment poorly. Equianalgesic ratios for tapentadol to prior strong opioids were calculated. Patients rotated directly from prior WHO step III opioids to tapentadol. Patients received tapentadol PR (50-250 mg b.i.d.) during 5-week titration and 7-week maintenance periods. Tapentadol immediate release (IR) 50 mg (≤ twice/day, ≥ 4 h apart) was allowed (total daily dose of tapentadol PR and IR ≤ 500 mg/day). The primary endpoint was responder rate 1 at week 6 (percentage of patients with the same or less pain intensity [11-point numerical rating scale (NRS; 3-day average)] vs week -1). Responder rate 1 at week 6 (last observation carried forward [LOCF]) was 80.9% (76/94; P pain intensity and neuropathic pain symptoms were observed at weeks 6 and 12 with tapentadol PR (P comparable pain relief and improved tolerability versus prior strong opioids in patients with severe, chronic low back pain responding to WHO step III therapy. Conversion from strong opioids to tapentadol PR, with its two mechanisms of action, went smoothly considering overall effectiveness and tolerability outcomes. Equianalgesic ratios of tapentadol to oxycodone and other strong opioids were in line with other phase 3/3b studies.

  6. Insertion of Argos sequences into the B-loop of epidermal growth factor results in a low-affinity ligand with strong agonistic activity.

    Science.gov (United States)

    van de Poll, M L; van Vugt, M J; Lenferink, A E; van Zoelen, E J

    1997-06-17

    Recently, it has been shown that the activation of the Drosophila EGF receptor (DER) by its natural ligand Spitz is inhibited by Argos [Schweitzer, R., et al. (1995) Nature 376, 699-702]. Argos and Spitz both have an EGF-like domain which in the case of Argos differs from that of Spitz and other EGF receptor agonists in that it has an extended B-loop of 20 amino acids instead of 10 amino acids which in addition contains an unusual cluster of charged residues. To investigate whether B-loop sequences are an important determinant for receptor activation and play a causal role in the antagonistic activity of Argos, three human (h)EGF mutants were constructed in which amino acids derived from the Argos B-loop were introduced. In one mutant (E3A4E/B10), replacement of four amino acids in the B-loop of hEGF (123, E24, D27, and K28) by the corresponding Argos residues neither altered the binding affinity of the growth factor for the hEGF receptor nor did it change its ability to induce a mitogenic response. Insertion of 2 additional Argos residues (E3A4E/B12) or extension of the B-loop by 10 amino acids (E3A4E/B20) resulted, however, in a significant loss of binding affinity. In spite of this, both E3A4E/B12 and E3A4E/B20 appeared to be strong agonists for the hEGF receptor with similar dose-response curves for mitogenic activity and MAPK activation as wild-type hEGF. These data show that several nonconservative substitutions in the hEGF B-loop are tolerated without affecting receptor binding or activation. Furthermore, they show that receptor binding and receptor signaling efficiency can be uncoupled which is a prerequisite for the development of receptor antagonists.

  7. Comprehensive numerical methodology for direct numerical simulations of compressible Rayleigh-Taylor instability

    Energy Technology Data Exchange (ETDEWEB)

    Reckinger, Scott James [Montana State Univ., Bozeman, MT (United States); Livescu, Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Vasilyev, Oleg V. [Univ. of Colorado, Boulder, CO (United States)

    2016-09-02

    A comprehensive numerical methodology has been developed that handles the challenges introduced by considering the compressive nature of Rayleigh-Taylor instability (RTI) systems, which include sharp interfacial density gradients on strongly stratified background states, acoustic wave generation and removal at computational boundaries, and stratification-dependent vorticity production. The computational framework is used to simulate two-dimensional single-mode RTI to extreme late-times for a wide range of flow compressibility and variable density effects. The results show that flow compressibility acts to reduce the growth of RTI for low Atwood numbers, as predicted from linear stability analysis.

  8. Modelling for Fuel Optimal Control of a Variable Compression Engine

    OpenAIRE

    Nilsson, Ylva

    2007-01-01

    Variable compression engines are a mean to meet the demand on lower fuel consumption. A high compression ratio results in high engine efficiency, but also increases the knock tendency. On conventional engines with fixed compression ratio, knock is avoided by retarding the ignition angle. The variable compression engine offers an extra dimension in knock control, since both ignition angle and compression ratio can be adjusted. The central question is thus for what combination of compression ra...

  9. Ultrahigh Pressure Dynamic Compression

    Science.gov (United States)

    Duffy, T. S.

    2017-12-01

    Laser-based dynamic compression provides a new opportunity to study the lattice structure and other properties of geological materials to ultrahigh pressure conditions ranging from 100 - 1000 GPa (1 TPa) and beyond. Such studies have fundamental applications to understanding the Earth's core as well as the interior structure of super-Earths and giant planets. This talk will review recent dynamic compression experiments using high-powered lasers on materials including Fe-Si, MgO, and SiC. Experiments were conducted at the Omega laser (University of Rochester) and the Linac Coherent Light Source (LCLS, Stanford). At Omega, laser drives as large as 2 kJ are applied over 10 ns to samples that are 50 microns thick. At peak compression, the sample is probed with quasi-monochromatic X-rays from a laser-plasma source and diffraction is recorded on image plates. At LCLS, shock waves are driven into the sample using a 40-J laser with a 10-ns pulse. The sample is probed with X-rays form the LCLS free electron laser providing 1012 photons in a monochromatic pulse near 10 keV energy. Diffraction is recorded using pixel array detectors. By varying the delay between the laser and the x-ray beam, the sample can be probed at various times relative to the shock wave transiting the sample. By controlling the shape and duration of the incident laser pulse, either shock or ramp (shockless) loading can be produced. Ramp compression produces less heating than shock compression, allowing samples to be probed to ultrahigh pressures without melting. Results for iron alloys, oxides, and carbides provide new constraints on equations of state and phase transitions that are relevant to the interior structure of large, extrasolar terrestrial-type planets.

  10. Intermittent pneumatic compression of legs increases microcirculation in distant skeletal muscle.

    Science.gov (United States)

    Liu, K; Chen, L E; Seaber, A V; Johnson, G W; Urbaniak, J R

    1999-01-01

    Intermittent pneumatic compression has been established as a method of clinically preventing deep vein thrombosis, but the mechanism has not been documented. This study observed the effects of intermittent pneumatic compression of legs on the microcirculation of distant skeletal muscle. The cremaster muscles of 80 male rats were exposed, a specially designed intermittent pneumatic-compression device was applied to both legs for 60 minutes, and the microcirculation of the muscles was assessed by measurement of the vessel diameter in three categories (10-20, 21-40, and 41-70 microm) for 120 minutes. The results showed significant vasodilation in arterial and venous vessels during the application of intermittent pneumatic compression, which disappeared after termination of the compression. The vasodilation reached a maximum 30 minutes after initiation of the compression and could be completely blocked by an inhibitor of nitric oxide synthase, NG-monomethyl-L-arginine (10 micromol/min). A 120-minute infusion of NG-monomethyl-L-arginine, beginning coincident with 60 minutes of intermittent pneumatic compression, resulted in a significant decrease in arterial diameter that remained at almost the same level after termination of the compression. The magnitude of the decrease in diameter in the group treated with intermittent pneumatic compression and NG-monomethyl-L-arginine was comparable with that in the group treated with NG-monomethyl-L-arginine alone. The results imply that the production of nitric oxide is involved in the positive influence of intermittent pneumatic compression on circulation. It is postulated that the rapid increase in venous velocity induced by intermittent pneumatic compression produces strong shear stress on the vascular endothelium, which stimulates an increased release of nitric oxide and thereby causes systemic vasodilation.

  11. Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions

    Science.gov (United States)

    Eraso, Francisco E.; Analoui, Mostafa; Watson, Andrew B.; Rebeschini, Regina

    2002-01-01

    OBJECTIVES: The purpose of this study was to evaluate the lossy Joint Photographic Experts Group compression for endodontic pretreatment digital radiographs. STUDY DESIGN: Fifty clinical charge-coupled device-based, digital radiographs depicting periapical areas were selected. Each image was compressed at 2, 4, 8, 16, 32, 48, and 64 compression ratios. One root per image was marked for examination. Images were randomized and viewed by four clinical observers under standardized viewing conditions. Each observer read the image set three times, with at least two weeks between each reading. Three pre-selected sites per image (mesial, distal, apical) were scored on a five-scale score confidence scale. A panel of three examiners scored the uncompressed images, with a consensus score for each site. The consensus score was used as the baseline for assessing the impact of lossy compression on the diagnostic values of images. The mean absolute error between consensus and observer scores was computed for each observer, site, and reading session. RESULTS: Balanced one-way analysis of variance for all observers indicated that for compression ratios 48 and 64, there was significant difference between mean absolute error of uncompressed and compressed images (P <.05). After converting the five-scale score to two-level diagnostic values, the diagnostic accuracy was strongly correlated (R (2) = 0.91) with the compression ratio. CONCLUSION: The results of this study suggest that high compression ratios can have a severe impact on the diagnostic quality of the digital radiographs for detection of periapical lesions.

  12. Compressibility of carbon fabrics with needleless electrospun PAN nanofibrous interleaves

    Directory of Open Access Journals (Sweden)

    S. V. Lomov

    2016-01-01

    Full Text Available The present paper investigates how the presence of nanofiber interleaves affects the compressibility of the layup during manufacturing of the composites and hence determining the theoretically attainable fiber volume fraction at the given processing pressure. The results show that up to the interleave areal density of 10 g/m2 per nanofiber layer the decrease of fiber volume fraction does not exceed 3% for a laminate of carbon fiber woven fabric. Interleaves inside a fabric laminate are more compressible than a plain electrospun veil. It can be explained as the nanofibers penetrate between the carbon fibers when applying compression during composite manufacturing. It can be stated that there is a strong interference between the interleaves and the carbon reinforcement, which can lead to effective toughness improvement of the composite without significant alteration of fiber volume content.

  13. Evaluation of mammogram compression efficiency

    International Nuclear Information System (INIS)

    Przelaskowski, A.; Surowski, P.; Kukula, A.

    2005-01-01

    Lossy image coding significantly improves performance over lossless methods, but a reliable control of diagnostic accuracy regarding compressed images is necessary. The acceptable range of compression ratios must be safe with respect to as many objective criteria as possible. This study evaluates the compression efficiency of digital mammograms in both numerically lossless (reversible) and lossy (irreversible) manner. Effective compression methods and concepts were examined to increase archiving and telediagnosis performance. Lossless compression as a primary applicable tool for medical applications was verified on a set 131 mammograms. Moreover, nine radiologists participated in the evaluation of lossy compression of mammograms. Subjective rating of diagnostically important features brought a set of mean rates given for each test image. The lesion detection test resulted in binary decision data analyzed statistically. The radiologists rated and interpreted malignant and benign lesions, representative pathology symptoms, and other structures susceptible to compression distortions contained in 22 original and 62 reconstructed mammograms. Test mammograms were collected in two radiology centers for three years and then selected according to diagnostic content suitable for an evaluation of compression effects. Lossless compression efficiency of the tested coders varied, but CALIC, JPEG-LS, and SPIHT performed the best. The evaluation of lossy compression effects affecting detection ability was based on ROC-like analysis. Assuming a two-sided significance level of p=0.05, the null hypothesis that lower bit rate reconstructions are as useful for diagnosis as the originals was false in sensitivity tests with 0.04 bpp mammograms. However, verification of the same hypothesis with 0.1 bpp reconstructions suggested their acceptance. Moreover, the 1 bpp reconstructions were rated very similarly to the original mammograms in the diagnostic quality evaluation test, but the

  14. Image quality (IQ) guided multispectral image compression

    Science.gov (United States)

    Zheng, Yufeng; Chen, Genshe; Wang, Zhonghai; Blasch, Erik

    2016-05-01

    Image compression is necessary for data transportation, which saves both transferring time and storage space. In this paper, we focus on our discussion on lossy compression. There are many standard image formats and corresponding compression algorithms, for examples, JPEG (DCT -- discrete cosine transform), JPEG 2000 (DWT -- discrete wavelet transform), BPG (better portable graphics) and TIFF (LZW -- Lempel-Ziv-Welch). The image quality (IQ) of decompressed image will be measured by numerical metrics such as root mean square error (RMSE), peak signal-to-noise ratio (PSNR), and structural Similarity (SSIM) Index. Given an image and a specified IQ, we will investigate how to select a compression method and its parameters to achieve an expected compression. Our scenario consists of 3 steps. The first step is to compress a set of interested images by varying parameters and compute their IQs for each compression method. The second step is to create several regression models per compression method after analyzing the IQ-measurement versus compression-parameter from a number of compressed images. The third step is to compress the given image with the specified IQ using the selected compression method (JPEG, JPEG2000, BPG, or TIFF) according to the regressed models. The IQ may be specified by a compression ratio (e.g., 100), then we will select the compression method of the highest IQ (SSIM, or PSNR). Or the IQ may be specified by a IQ metric (e.g., SSIM = 0.8, or PSNR = 50), then we will select the compression method of the highest compression ratio. Our experiments tested on thermal (long-wave infrared) images (in gray scales) showed very promising results.

  15. Mammography image compression using Wavelet

    International Nuclear Information System (INIS)

    Azuhar Ripin; Md Saion Salikin; Wan Hazlinda Ismail; Asmaliza Hashim; Norriza Md Isa

    2004-01-01

    Image compression plays an important role in many applications like medical imaging, televideo conferencing, remote sensing, document and facsimile transmission, which depend on the efficient manipulation, storage, and transmission of binary, gray scale, or color images. In Medical imaging application such Picture Archiving and Communication System (PACs), the image size or image stream size is too large and requires a large amount of storage space or high bandwidth for communication. Image compression techniques are divided into two categories namely lossy and lossless data compression. Wavelet method used in this project is a lossless compression method. In this method, the exact original mammography image data can be recovered. In this project, mammography images are digitized by using Vider Sierra Plus digitizer. The digitized images are compressed by using this wavelet image compression technique. Interactive Data Language (IDLs) numerical and visualization software is used to perform all of the calculations, to generate and display all of the compressed images. Results of this project are presented in this paper. (Author)

  16. Computed Quality Assessment of MPEG4-compressed DICOM Video Data.

    Science.gov (United States)

    Frankewitsch, Thomas; Söhnlein, Sven; Müller, Marcel; Prokosch, Hans-Ulrich

    2005-01-01

    Digital Imaging and Communication in Medicine (DICOM) has become one of the most popular standards in medicine. This standard specifies the exact procedures in which digital images are exchanged between devices, either using a network or storage medium. Sources for images vary; therefore there exist definitions for the exchange for CR, CT, NMR, angiography, sonography and so on. With its spreading, with the increasing amount of sources included, data volume is increasing, too. This affects storage and traffic. While for long-time storage data compression is generally not accepted at the moment, there are many situations where data compression is possible: Telemedicine for educational purposes (e.g. students at home using low speed internet connections), presentations with standard-resolution video projectors, or even the supply on wards combined receiving written findings. DICOM comprises compression: for still image there is JPEG, for video MPEG-2 is adopted. Within the last years MPEG-2 has been evolved to MPEG-4, which squeezes data even better, but the risk of significant errors increases, too. Within the last years effects of compression have been analyzed for entertainment movies, but these are not comparable to videos of physical examinations (e.g. echocardiography). In medical videos an individual image plays a more important role. Erroneous single images affect total quality even more. Additionally, the effect of compression can not be generalized from one test series to all videos. The result depends strongly on the source. Some investigations have been presented, where different MPEG-4 algorithms compressed videos have been compared and rated manually. But they describe only the results in an elected testbed. In this paper some methods derived from video rating are presented and discussed for an automatically created quality control for the compression of medical videos, primary stored in DICOM containers.

  17. Effect of Compression Ratio on Perception of Time Compressed Phonemically Balanced Words in Kannada and Monosyllables.

    Science.gov (United States)

    Prabhu, Prashanth; Sujan, Mirale Jagadish; Rakshith, Satish

    2015-01-21

    The present study attempted to study perception of time-compressed speech and the effect of compression ratio for phonemically balanced (PB) word lists in Kannada and monosyllables. The test was administered on 30 normal hearing individuals at compression ratios of 40%, 50%, 60%, 70% and 80% for PB words in Kannada and monosyllables. The results of the study showed that the speech identification scores for time-compressed speech reduced with increase in compression ratio. The scores were better for monosyllables compared to PB words especially at higher compression ratios. The study provides speech identification scores at different compression ratio for PB words and monosyllables in individuals with normal hearing. The results of the study also showed that the scores did not vary across gender for all the compression ratios for both the stimuli. The same test material needs to be compared the clinical population with central auditory processing disorder for clinical validation of the present results.

  18. Effect of compression ratio on perception of time compressed phonemically balanced words in Kannada and monosyllables

    Directory of Open Access Journals (Sweden)

    Prashanth Prabhu

    2015-03-01

    Full Text Available The present study attempted to study perception of time-compressed speech and the effect of compression ratio for phonemically balanced (PB word lists in Kannada and monosyllables. The test was administered on 30 normal hearing individuals at compression ratios of 40%, 50%, 60%, 70% and 80% for PB words in Kannada and monosyllables. The results of the study showed that the speech identification scores for time-compressed speech reduced with increase in compression ratio. The scores were better for monosyllables compared to PB words especially at higher compression ratios. The study provides speech identification scores at different compression ratio for PB words and monosyllables in individuals with normal hearing. The results of the study also showed that the scores did not vary across gender for all the compression ratios for both the stimuli. The same test material needs to be compared the clinical population with central auditory processing disorder for clinical validation of the present results.

  19. Compressing DNA sequence databases with coil

    Directory of Open Access Journals (Sweden)

    Hendy Michael D

    2008-05-01

    Full Text Available Abstract Background Publicly available DNA sequence databases such as GenBank are large, and are growing at an exponential rate. The sheer volume of data being dealt with presents serious storage and data communications problems. Currently, sequence data is usually kept in large "flat files," which are then compressed using standard Lempel-Ziv (gzip compression – an approach which rarely achieves good compression ratios. While much research has been done on compressing individual DNA sequences, surprisingly little has focused on the compression of entire databases of such sequences. In this study we introduce the sequence database compression software coil. Results We have designed and implemented a portable software package, coil, for compressing and decompressing DNA sequence databases based on the idea of edit-tree coding. coil is geared towards achieving high compression ratios at the expense of execution time and memory usage during compression – the compression time represents a "one-off investment" whose cost is quickly amortised if the resulting compressed file is transmitted many times. Decompression requires little memory and is extremely fast. We demonstrate a 5% improvement in compression ratio over state-of-the-art general-purpose compression tools for a large GenBank database file containing Expressed Sequence Tag (EST data. Finally, coil can efficiently encode incremental additions to a sequence database. Conclusion coil presents a compelling alternative to conventional compression of flat files for the storage and distribution of DNA sequence databases having a narrow distribution of sequence lengths, such as EST data. Increasing compression levels for databases having a wide distribution of sequence lengths is a direction for future work.

  20. Computation of local exchange coefficients in strongly interacting one-dimensional few-body systems: local density approximation and exact results

    DEFF Research Database (Denmark)

    Marchukov, O. V.; Eriksen, E. H.; Midtgaard, J. M.

    2016-01-01

    One-dimensional multi-component Fermi or Bose systems with strong zero-range interactions can be described in terms of local exchange coefficients and mapping the problem into a spin model is thus possible. For arbitrary external confining potentials the local exchanges are given by highly non...... to the computational complexity of the high-dimensional integrals involved. An approach using the local density approximation would therefore be a most welcome approximation due to its simplicity. Here we assess the accuracy of the local density approximation by going beyond the simple harmonic oscillator that has...... been the focus of previous studies and consider some double-wells of current experimental interest. We find that the local density approximation works quite well as long as the potentials resemble harmonic wells but break down for larger barriers. In order to explore the consequences of applying...

  1. Fingerprints in Compressed Strings

    DEFF Research Database (Denmark)

    Bille, Philip; Cording, Patrick Hagge; Gørtz, Inge Li

    2013-01-01

    The Karp-Rabin fingerprint of a string is a type of hash value that due to its strong properties has been used in many string algorithms. In this paper we show how to construct a data structure for a string S of size N compressed by a context-free grammar of size n that answers fingerprint queries....... That is, given indices i and j, the answer to a query is the fingerprint of the substring S[i,j]. We present the first O(n) space data structures that answer fingerprint queries without decompressing any characters. For Straight Line Programs (SLP) we get O(logN) query time, and for Linear SLPs (an SLP...... derivative that captures LZ78 compression and its variations) we get O(loglogN) query time. Hence, our data structures has the same time and space complexity as for random access in SLPs. We utilize the fingerprint data structures to solve the longest common extension problem in query time O(logNlogℓ) and O...

  2. Efficient Lossy Compression for Compressive Sensing Acquisition of Images in Compressive Sensing Imaging Systems

    Directory of Open Access Journals (Sweden)

    Xiangwei Li

    2014-12-01

    Full Text Available Compressive Sensing Imaging (CSI is a new framework for image acquisition, which enables the simultaneous acquisition and compression of a scene. Since the characteristics of Compressive Sensing (CS acquisition are very different from traditional image acquisition, the general image compression solution may not work well. In this paper, we propose an efficient lossy compression solution for CS acquisition of images by considering the distinctive features of the CSI. First, we design an adaptive compressive sensing acquisition method for images according to the sampling rate, which could achieve better CS reconstruction quality for the acquired image. Second, we develop a universal quantization for the obtained CS measurements from CS acquisition without knowing any a priori information about the captured image. Finally, we apply these two methods in the CSI system for efficient lossy compression of CS acquisition. Simulation results demonstrate that the proposed solution improves the rate-distortion performance by 0.4~2 dB comparing with current state-of-the-art, while maintaining a low computational complexity.

  3. Super-strong Magnetic Field in Sunspots

    Science.gov (United States)

    Okamoto, Takenori J.; Sakurai, Takashi

    2018-01-01

    Sunspots are the most notable structure on the solar surface with strong magnetic fields. The field is generally strongest in a dark area (umbra), but sometimes stronger fields are found in non-dark regions, such as a penumbra and a light bridge. The formation mechanism of such strong fields outside umbrae is still puzzling. Here we report clear evidence of the magnetic field of 6250 G, which is the strongest field among Stokes I profiles with clear Zeeman splitting ever observed on the Sun. The field was almost parallel to the solar surface and located in a bright region sandwiched by two opposite-polarity umbrae. Using a time series of spectral data sets, we discuss the formation process of the super-strong field and suggest that this strong field region was generated as a result of compression of one umbra pushed by the horizontal flow from the other umbra, such as the subduction of the Earth’s crust in plate tectonics.

  4. INSTRUMENTS AND METHODS OF INVESTIGATION: Dynamic compression of hydrogen isotopes at megabar pressures

    Science.gov (United States)

    Trunin, Ryurik F.; Urlin, Vitalii D.; Medvedev, Aleksandr B.

    2010-09-01

    We review the results of shock compression of solid protium to the pressure 66 GPa, of liquid deuterium to 110 GPa, and of solid deuterium to 123 GPa in explosive devices of spherical geometry. The results are compared with data obtained by US scientists using traditional energy sources (explosives and light-gas guns), striker acceleration in a strong magnetic field (Z facility at Sandia), and powerful lasers (Nova at Lawrence Livermore National Laboratory (LLNL) and Omega at the Laboratory for Laser Energetics, University of Rochester). Results of density measurements of hydrogen isotopes under quasi-isentropic compression are analyzed. The absence of an anomalous increase in density under shock and quasi-isentropic compression of hydrogen isotopes is demonstrated. On the other hand, both processes exhibit a sharp change in the compression curve slopes, at the respective pressures 45 and 300 GPa.

  5. Scale adaptive compressive tracking.

    Science.gov (United States)

    Zhao, Pengpeng; Cui, Shaohui; Gao, Min; Fang, Dan

    2016-01-01

    Recently, the compressive tracking (CT) method (Zhang et al. in Proceedings of European conference on computer vision, pp 864-877, 2012) has attracted much attention due to its high efficiency, but it cannot well deal with the scale changing objects due to its constant tracking box. To address this issue, in this paper we propose a scale adaptive CT approach, which adaptively adjusts the scale of tracking box with the size variation of the objects. Our method significantly improves CT in three aspects: Firstly, the scale of tracking box is adaptively adjusted according to the size of the objects. Secondly, in the CT method, all the compressive features are supposed independent and equal contribution to the classifier. Actually, different compressive features have different confidence coefficients. In our proposed method, the confidence coefficients of features are computed and used to achieve different contribution to the classifier. Finally, in the CT method, the learning parameter λ is constant, which will result in large tracking drift on the occasion of object occlusion or large scale appearance variation. In our proposed method, a variable learning parameter λ is adopted, which can be adjusted according to the object appearance variation rate. Extensive experiments on the CVPR2013 tracking benchmark demonstrate the superior performance of the proposed method compared to state-of-the-art tracking algorithms.

  6. Compressed sensing electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Leary, Rowan, E-mail: rkl26@cam.ac.uk [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Saghi, Zineb; Midgley, Paul A. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Holland, Daniel J. [Department of Chemical Engineering and Biotechnology, University of Cambridge, New Museums Site, Pembroke Street, Cambridge CB2 3RA (United Kingdom)

    2013-08-15

    The recent mathematical concept of compressed sensing (CS) asserts that a small number of well-chosen measurements can suffice to reconstruct signals that are amenable to sparse or compressible representation. In addition to powerful theoretical results, the principles of CS are being exploited increasingly across a range of experiments to yield substantial performance gains relative to conventional approaches. In this work we describe the application of CS to electron tomography (ET) reconstruction and demonstrate the efficacy of CS–ET with several example studies. Artefacts present in conventional ET reconstructions such as streaking, blurring of object boundaries and elongation are markedly reduced, and robust reconstruction is shown to be possible from far fewer projections than are normally used. The CS–ET approach enables more reliable quantitative analysis of the reconstructions as well as novel 3D studies from extremely limited data. - Highlights: • Compressed sensing (CS) theory and its application to electron tomography (ET) is described. • The practical implementation of CS–ET is outlined and its efficacy demonstrated with examples. • High fidelity tomographic reconstruction is possible from a small number of images. • The CS–ET reconstructions can be more reliably segmented and analysed quantitatively. • CS–ET is applicable to different image content by choice of an appropriate sparsifying transform.

  7. Excessive chest compression rate is associated with insufficient compression depth in prehospital cardiac arrest.

    Science.gov (United States)

    Monsieurs, Koenraad G; De Regge, Melissa; Vansteelandt, Kristof; De Smet, Jeroen; Annaert, Emmanuel; Lemoyne, Sabine; Kalmar, Alain F; Calle, Paul A

    2012-11-01

    BACKGROUND AND GOAL OF STUDY: The relationship between chest compression rate and compression depth is unknown. In order to characterise this relationship, we performed an observational study in prehospital cardiac arrest patients. We hypothesised that faster compressions are associated with decreased depth. In patients undergoing prehospital cardiopulmonary resuscitation by health care professionals, chest compression rate and depth were recorded using an accelerometer (E-series monitor-defibrillator, Zoll, U.S.A.). Compression depth was compared for rates 120/min. A difference in compression depth ≥0.5 cm was considered clinically significant. Mixed models with repeated measurements of chest compression depth and rate (level 1) nested within patients (level 2) were used with compression rate as a continuous and as a categorical predictor of depth. Results are reported as means and standard error (SE). One hundred and thirty-three consecutive patients were analysed (213,409 compressions). Of all compressions 2% were 120/min, 36% were 5 cm. In 77 out of 133 (58%) patients a statistically significant lower depth was observed for rates >120/min compared to rates 80-120/min, in 40 out of 133 (30%) this difference was also clinically significant. The mixed models predicted that the deepest compression (4.5 cm) occurred at a rate of 86/min, with progressively lower compression depths at higher rates. Rates >145/min would result in a depth compression depth for rates 80-120/min was on average 4.5 cm (SE 0.06) compared to 4.1 cm (SE 0.06) for compressions >120/min (mean difference 0.4 cm, Pcompression rates and lower compression depths. Avoiding excessive compression rates may lead to more compressions of sufficient depth. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  8. Compressed gas fuel storage system

    Science.gov (United States)

    Wozniak, John J.; Tiller, Dale B.; Wienhold, Paul D.; Hildebrand, Richard J.

    2001-01-01

    A compressed gas vehicle fuel storage system comprised of a plurality of compressed gas pressure cells supported by shock-absorbing foam positioned within a shape-conforming container. The container is dimensioned relative to the compressed gas pressure cells whereby a radial air gap surrounds each compressed gas pressure cell. The radial air gap allows pressure-induced expansion of the pressure cells without resulting in the application of pressure to adjacent pressure cells or physical pressure to the container. The pressure cells are interconnected by a gas control assembly including a thermally activated pressure relief device, a manual safety shut-off valve, and means for connecting the fuel storage system to a vehicle power source and a refueling adapter. The gas control assembly is enclosed by a protective cover attached to the container. The system is attached to the vehicle with straps to enable the chassis to deform as intended in a high-speed collision.

  9. Compressed sensing for distributed systems

    CERN Document Server

    Coluccia, Giulio; Magli, Enrico

    2015-01-01

    This book presents a survey of the state-of-the art in the exciting and timely topic of compressed sensing for distributed systems. It has to be noted that, while compressed sensing has been studied for some time now, its distributed applications are relatively new. Remarkably, such applications are ideally suited to exploit all the benefits that compressed sensing can provide. The objective of this book is to provide the reader with a comprehensive survey of this topic, from the basic concepts to different classes of centralized and distributed reconstruction algorithms, as well as a comparison of these techniques. This book collects different contributions on these aspects. It presents the underlying theory in a complete and unified way for the first time, presenting various signal models and their use cases. It contains a theoretical part collecting latest results in rate-distortion analysis of distributed compressed sensing, as well as practical implementations of algorithms obtaining performance close to...

  10. Compression for preventing recurrence of venous ulcers.

    Science.gov (United States)

    Nelson, E Andrea; Bell-Syer, Sally E M

    2014-09-09

    Up to 1% of adults will have a leg ulcer at some time. The majority of leg ulcers are venous in origin and are caused by high pressure in the veins due to blockage or weakness of the valves in the veins of the leg. Prevention and treatment of venous ulcers is aimed at reducing the pressure either by removing/repairing the veins, or by applying compression bandages/stockings to reduce the pressure in the veins.The majority of venous ulcers heal with compression bandages, however ulcers frequently recur. Clinical guidelines therefore recommend that people continue to wear compression, usually in the form of hosiery (tights, stockings, socks) after their ulcer heals, to prevent recurrence. To assess the effects of compression (socks, stockings, tights, bandages) in preventing the recurrence of venous ulcers. If compression does prevent ulceration compared with no compression, then to identify whether there is evidence to recommend particular levels of compression (high, medium or low, for example), types of compression, or brands of compression to prevent ulcer recurrence after healing. For this second update we searched The Cochrane Wounds Group Specialised Register (searched 4 September 2014) which includes the results of regular searches of MEDLINE, EMBASE and CINAHL; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 8). Randomised controlled trials (RCTs)evaluating compression bandages or hosiery for preventing the recurrence of venous ulcers. Two review authors undertook data extraction and risk of bias assessment independently. Four trials (979 participants) were eligible for inclusion in this review. One trial in patients with recently healed venous ulcers (n = 153) compared recurrence rates with and without compression and found that compression significantly reduced ulcer recurrence at six months (Risk ratio (RR) 0.46, 95% CI 0.27 to 0.76).Two trials compared high-compression hosiery (equivalent to UK class 3) with

  11. Strong Cosmic Censorship

    Science.gov (United States)

    Isenberg, James

    2017-01-01

    The Hawking-Penrose theorems tell us that solutions of Einstein's equations are generally singular, in the sense of the incompleteness of causal geodesics (the paths of physical observers). These singularities might be marked by the blowup of curvature and therefore crushing tidal forces, or by the breakdown of physical determinism. Penrose has conjectured (in his `Strong Cosmic Censorship Conjecture`) that it is generically unbounded curvature that causes singularities, rather than causal breakdown. The verification that ``AVTD behavior'' (marked by the domination of time derivatives over space derivatives) is generically present in a family of solutions has proven to be a useful tool for studying model versions of Strong Cosmic Censorship in that family. I discuss some of the history of Strong Cosmic Censorship, and then discuss what is known about AVTD behavior and Strong Cosmic Censorship in families of solutions defined by varying degrees of isometry, and discuss recent results which we believe will extend this knowledge and provide new support for Strong Cosmic Censorship. I also comment on some of the recent work on ``Weak Null Singularities'', and how this relates to Strong Cosmic Censorship.

  12. The Significance of Education for Mortality Compression in the United States*

    Science.gov (United States)

    Brown, Dustin C.; Hayward, Mark D.; Montez, Jennifer Karas; Humme, Robert A.; Chiu, Chi-Tsun; Hidajat, Mira M.

    2012-01-01

    Recent studies of old-age mortality trends assess whether longevity improvements over time are linked to increasing compression of mortality at advanced ages. The historical backdrop of these studies is the long-term improvements in a population's socioeconomic resources that fueled longevity gains. We extend this line of inquiry by examining whether socioeconomic differences in longevity within a population are accompanied by old-age mortality compression. Specifically, we document educational differences in longevity and mortality compression for older men and women in the United States. Drawing on the fundamental cause of disease framework, we hypothesize that both longevity and compression increase with higher levels of education and that women with the highest levels of education will exhibit the greatest degree of longevity and compression. Results based on the Health and Retirement Study and the National Health Interview Survey Linked Mortality File confirm a strong educational gradient in both longevity and mortality compression. We also find that mortality is more compressed within educational groups among women than men. The results suggest that educational attainment in the United States maximizes life chances by delaying the biological aging process. PMID:22556045

  13. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix

    2014-06-22

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  14. Microbunching and RF Compression

    International Nuclear Information System (INIS)

    Venturini, M.; Migliorati, M.; Ronsivalle, C.; Ferrario, M.; Vaccarezza, C.

    2010-01-01

    Velocity bunching (or RF compression) represents a promising technique complementary to magnetic compression to achieve the high peak current required in the linac drivers for FELs. Here we report on recent progress aimed at characterizing the RF compression from the point of view of the microbunching instability. We emphasize the development of a linear theory for the gain function of the instability and its validation against macroparticle simulations that represents a useful tool in the evaluation of the compression schemes for FEL sources.

  15. Atomic effect algebras with compression bases

    International Nuclear Information System (INIS)

    Caragheorgheopol, Dan; Tkadlec, Josef

    2011-01-01

    Compression base effect algebras were recently introduced by Gudder [Demonstr. Math. 39, 43 (2006)]. They generalize sequential effect algebras [Rep. Math. Phys. 49, 87 (2002)] and compressible effect algebras [Rep. Math. Phys. 54, 93 (2004)]. The present paper focuses on atomic compression base effect algebras and the consequences of atoms being foci (so-called projections) of the compressions in the compression base. Part of our work generalizes results obtained in atomic sequential effect algebras by Tkadlec [Int. J. Theor. Phys. 47, 185 (2008)]. The notion of projection-atomicity is introduced and studied, and several conditions that force a compression base effect algebra or the set of its projections to be Boolean are found. Finally, we apply some of these results to sequential effect algebras and strengthen a previously established result concerning a sufficient condition for them to be Boolean.

  16. Viscoelastic behavior of basaltic ash from Stromboli volcano inferred from intermittent compression experiments

    Science.gov (United States)

    Kurokawa, A. K.; Miwa, T.; Okumura, S.; Uesugi, K.

    2017-12-01

    After ash-dominated Strombolian eruption, considerable amount of ash falls back to the volcanic conduit forming a dense near-surface region compacted by weights of its own and other fallback clasts (Patrick et al., 2007). Gas accumulation below this dense cap causes a substantial increase in pressure within the conduit, causing the volcanic activity to shift to the preliminary stages of a forthcoming eruption (Del Bello et al., 2015). Under such conditions, rheology of the fallback ash plays an important role because it controls whether the fallback ash can be the cap. However, little attention has been given to the point. We examined the rheology of ash collected at Stromboli volcano via intermittent compression experiments changing temperature and compression time/rate. The ash deformed at a constant rate during compression process, and then it was compressed without any deformation during rest process. The compression and rest processes repeated during each experiment to see rheological variations with progression of compaction. Viscoelastic changes during the experiment were estimated by Maxwell model. The results show that both elasticity and viscosity increases with decreasing porosity. On the other hand, the elasticity shows strong rate-dependence in the both compression and rest processes while the viscosity dominantly depends on the temperature, although the compression rate also affects the viscosity in the case of the compression process. Thus, the ash behaves either elastically or viscously depending on experimental process, temperature, and compression rate/time. The viscoelastic characteristics can be explained by magnitude relationships between the characteristic relaxation times and times for compression and rest processes. This indicates that the balance of the time scales is key to determining the rheological characteristics and whether the ash behaves elastically or viscously may control cyclic Strombolian eruptions.

  17. Compression test assembly

    Science.gov (United States)

    Kariotis, A. H. (Inventor)

    1973-01-01

    A compression test assembly is described which prevents buckling of small diameter rigid specimens undergoing compression testing and permits attachment of extensometers for strain measurements. The test specimen is automatically aligned and laterally supported when compressive force is applied to the end caps and transmitted to the test specimen during testing.

  18. A strong comeback

    International Nuclear Information System (INIS)

    Marier, D.

    1992-01-01

    This article presents the results of a financial rankings survey which show a strong economic activity in the independent energy industry. The topics of the article include advisor turnover, overseas banks, and the increase in public offerings. The article identifies the top project finance investors for new projects and restructurings and rankings for lenders

  19. Compression Characteristics of Solid Wastes as Backfill Materials

    OpenAIRE

    Meng Li; Jixiong Zhang; Rui Gao

    2016-01-01

    A self-made large-diameter compression steel chamber and a SANS material testing machine were chosen to perform a series of compression tests in order to fully understand the compression characteristics of differently graded filling gangue samples. The relationship between the stress-deformation modulus and stress-compression degree was analyzed comparatively. The results showed that, during compression, the deformation modulus of gangue grew linearly with stress, the overall relationship bet...

  20. The grain size dependency of vesicular particle shapes strongly affects the drag of particles. First results from microtomography investigations of Campi Flegrei fallout deposits

    Science.gov (United States)

    Mele, Daniela; Dioguardi, Fabio

    2018-03-01

    Acknowledging the grain size dependency of shape is important in volcanology, in particular when dealing with tephra produced and emplaced during and after explosive volcanic eruptions. A systematic measurement of the tridimensional shape of vesicular pyroclasts of Campi Flegrei fallout deposits (Agnano-Monte Spina, Astroni 6 and Averno 2 eruptions) varying in size from 8.00 to 0.016 mm has been carried out by means of X-Ray Microtomography. Data show that particle shape changes with size, especially for juvenile vesicular clasts, since it is dependent on the distribution and size of vesicles that contour the external clast outline. Two drag laws that include sphericity in the formula were used for estimating the dependency of settling velocity on shape. Results demonstrate that it is not appropriate to assume a size-independent shape for vesicular particles, in contrast with the approach commonly employed when simulating the ash dispersion in the atmosphere.

  1. <strong>OPTIMIZATION OF IMMOBILIZED METAL strong>>ION AFFINITYstrong>> strong>>CHROMATOGRAPHY strong>>FOR strong>>PHOSPHOPEPTIDE ENRICHMENT  PRIOR TO strong>>MASS SPECTROMETRYstrong>

    DEFF Research Database (Denmark)

    Ye, Juanying; Zhang, Xumin; Young, Clifford

    simple procedures.     Methods Tryptic digests of standard phosphoproteins (bovine α,β- casein) and 3 non-phosphoproteins (bovine serum albumin, bovine β-lactoglobulin, and bovine carbonic anhydrase) with different ratios (1:50, 1:200, 1:500, 1:1000) were used for Fe(III)-IMAC (Qiagen Ni-NTA) enrichment.......   Results Fe(III)-IMAC using NTA-silica from Qiagen  showed a better performance than two other commercially available resins under the testing conditions. Increase of the acetonitrile content to 60% in loading and washing buffer significantly improved the specificity of IMAC enrichment. It was demonstrated...

  2. Vector mesons in strongly interacting matter

    Indian Academy of Sciences (India)

    probes like photons, pions or protons or the heated and compressed hadronic matter generated in a heavy-ion collision. Leaving any nuclear medium without strong final-state interactions, dileptons are the optimum decay channel as they avoid any final-state distortion of the 4- momenta of the decay products entering eq.

  3. Premixed autoignition in compressible turbulence

    Science.gov (United States)

    Konduri, Aditya; Kolla, Hemanth; Krisman, Alexander; Chen, Jacqueline

    2016-11-01

    Prediction of chemical ignition delay in an autoignition process is critical in combustion systems like compression ignition engines and gas turbines. Often, ignition delay times measured in simple homogeneous experiments or homogeneous calculations are not representative of actual autoignition processes in complex turbulent flows. This is due the presence of turbulent mixing which results in fluctuations in thermodynamic properties as well as chemical composition. In the present study the effect of fluctuations of thermodynamic variables on the ignition delay is quantified with direct numerical simulations of compressible isotropic turbulence. A premixed syngas-air mixture is used to remove the effects of inhomogeneity in the chemical composition. Preliminary results show a significant spatial variation in the ignition delay time. We analyze the topology of autoignition kernels and identify the influence of extreme events resulting from compressibility and intermittency. The dependence of ignition delay time on Reynolds and turbulent Mach numbers is also quantified. Supported by Basic Energy Sciences, Dept of Energy, United States.

  4. Compressible effect algebras

    Science.gov (United States)

    Gudder, Stan

    2004-08-01

    We define a special type of additive map J on an effect algebra E called a compression. We call J(1) the focus of J and if p is the focus of a compression then p is called a projection. The set of projections in E is denoted by P(E). A compression J is direct if J( a) ≤ a for all a ɛ E. We show that direct compressions are equivalent to projections onto components of cartesian products. An effect algebra E is said to be compressible if every compression on E is uniquely determined by its focus and every compression on E has a supplement. We define and characterize the commutant C(p) of a projection p and show that a compression with focus p is direct if and only if C(p) = E. We show that P(E) is an orthomodular poset. It is proved that the cartesian product of effect algebras is compressible if and only if each component is compressible. We then consider compressible sequential effect algebras, Lüders maps and conditional probabilities.

  5. Compressive Transient Imaging

    KAUST Repository

    Sun, Qilin

    2017-04-01

    High resolution transient/3D imaging technology is of high interest in both scientific research and commercial application. Nowadays, all of the transient imaging methods suffer from low resolution or time consuming mechanical scanning. We proposed a new method based on TCSPC and Compressive Sensing to achieve a high resolution transient imaging with a several seconds capturing process. Picosecond laser sends a serious of equal interval pulse while synchronized SPAD camera\\'s detecting gate window has a precise phase delay at each cycle. After capturing enough points, we are able to make up a whole signal. By inserting a DMD device into the system, we are able to modulate all the frames of data using binary random patterns to reconstruct a super resolution transient/3D image later. Because the low fill factor of SPAD sensor will make a compressive sensing scenario ill-conditioned, We designed and fabricated a diffractive microlens array. We proposed a new CS reconstruction algorithm which is able to denoise at the same time for the measurements suffering from Poisson noise. Instead of a single SPAD senor, we chose a SPAD array because it can drastically reduce the requirement for the number of measurements and its reconstruction time. Further more, it not easy to reconstruct a high resolution image with only one single sensor while for an array, it just needs to reconstruct small patches and a few measurements. In this thesis, we evaluated the reconstruction methods using both clean measurements and the version corrupted by Poisson noise. The results show how the integration over the layers influence the image quality and our algorithm works well while the measurements suffer from non-trival Poisson noise. It\\'s a breakthrough in the areas of both transient imaging and compressive sensing.

  6. Lossless Compression of Digital Images

    DEFF Research Database (Denmark)

    Martins, Bo

    are constructed by this principle. A multi-pass free tree coding scheme produces excellent compression results for all test images. A multi-pass fast free template coding scheme produces much better results than JBIG for difficult images, such as halftonings. Rissanen's algorithm `Context' is presented in a new...... version that is substantially faster than its precursorsand brings it close to the multi-pass coders in compression performance.Handprinted characters are of unequal complexity; recent work by Singer and Tishby demonstrates that utilizing the physiological process of writing one can synthesize cursive...

  7. Some recent results on strong interactions

    International Nuclear Information System (INIS)

    Diebold, R.

    1978-01-01

    A preview of a rapporteur talk is given on the three active fields of high energy hadron reactions with high multiplicity, charm searches and related topics, and ultrahigh energy events and exotic phenomena of cosmic radiation. 53 references

  8. Building indifferentiable compression functions from the PGV compression functions

    DEFF Research Database (Denmark)

    Gauravaram, P.; Bagheri, Nasour; Knudsen, Lars Ramkilde

    2016-01-01

    Preneel, Govaerts and Vandewalle (PGV) analysed the security of single-block-length block cipher based compression functions assuming that the underlying block cipher has no weaknesses. They showed that 12 out of 64 possible compression functions are collision and (second) preimage resistant. Black......, Rogaway and Shrimpton formally proved this result in the ideal cipher model. However, in the indifferentiability security framework introduced by Maurer, Renner and Holenstein, all these 12 schemes are easily differentiable from a fixed input-length random oracle (FIL-RO) even when their underlying block...

  9. Autophagy is activated in compression-induced cell degeneration and is mediated by reactive oxygen species in nucleus pulposus cells exposed to compression.

    Science.gov (United States)

    Ma, K-G; Shao, Z-W; Yang, S-H; Wang, J; Wang, B-C; Xiong, L-M; Wu, Q; Chen, S-F

    2013-12-01

    To determine whether autophagy contributes to the pathogenesis of degenerative disc disease (DDD) or retards the intervertebral disc (IVD) degeneration, and investigate the possible relationship between compression-induced autophagy and intracellular reactive oxygen species (ROS) in nucleus pulposus (NP) cells in vitro. The autophagosome and autophagy-related markers were used to explore the role of autophagy in rat NP cells under compressive stress, which were measured directly by electronic microscopy, monodansylcadaverine (MDC) staining, immunofluorescence, western blot, and indirectly by analyzing the impact of pharmacological inhibitors of autophagy such as 3-methyladenine (3-MA) and chloroquine (CQ). And the relationship between autophagy and apoptosis was investigated by Annexin-V/propidium iodide (PI)-fluorescein staining. In addition, ROS were measured to determine whether these factors are responsible for the development of compression-induced autophagy. Our results indicated that rat NP cells activated autophagy in response to the same strong apoptotic stimuli that triggered apoptosis by compression. Autophagy and apoptosis were interconnected and coordinated in rat NP cells exposed to compression stimuli. Compression-induced autophagy was closely related to intracellular ROS production. Enhanced degradation of damaged components of NP cells by autophagy may be a crucial survival response against mechanical overload, and extensive autophagy may trigger autophagic cell death. Regulating autophagy and reducing the generation of intracellular ROS may retard IVD degeneration. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. Compressibility effects in planar wakes

    Science.gov (United States)

    Hickey, Jean-Pierre; Hussain, Fazle; Wu, Xiaohua

    2010-11-01

    Far-field, temporally evolving planar wakes are studied by DNS to evaluate the effect of compressibility on the flow. A high-order predictor-corrector code was developed and fully validated against canonical compressible test cases. In this study, wake simulations are performed at constant Reynolds number for three different Mach numbers: Ma= 0.2, 0.8 and 1.2. The domain is doubly periodic with a non-reflecting boundary in the cross-flow and is initialized by a randomly perturbed laminar profile. The compressibility of the flow modifies the observed structures which show greater three-dimensionality. A self-similar period develops in which the square of the wake half-width increase linearly with time and the Reynolds stress statistics at various times collapse using proper scaling parameters. The growth-rate increases with increasing compressibility of the flow: an observation which is substantiated by experimental results but is in stark contrast with the high-speed mixing-layer. As the growth-rate is related to the mixing ability of the flow, the impact of compressibility is of fundamental importance. Therefore, we seek an explanation of the modified growth-rate by investigating the turbulent kinetic energy equation. From the analysis, it can be conjectured that the pressure-strain term might play a role in the modified growth-rate.

  11. Respiratory sounds compression.

    Science.gov (United States)

    Yadollahi, Azadeh; Moussavi, Zahra

    2008-04-01

    Recently, with the advances in digital signal processing, compression of biomedical signals has received great attention for telemedicine applications. In this paper, an adaptive transform coding-based method for compression of respiratory and swallowing sounds is proposed. Using special characteristics of respiratory sounds, the recorded signals are divided into stationary and nonstationary portions, and two different bit allocation methods (BAMs) are designed for each portion. The method was applied to the data of 12 subjects and its performance in terms of overall signal-to-noise ratio (SNR) values was calculated at different bit rates. The performance of different quantizers was also considered and the sensitivity of the quantizers to initial conditions has been alleviated. In addition, the fuzzy clustering method was examined for classifying the signal into different numbers of clusters and investigating the performance of the adaptive BAM with increasing the number of classes. Furthermore, the effects of assigning different numbers of bits for encoding stationary and nonstationary portions of the signal were studied. The adaptive BAM with variable number of bits was found to improve the SNR values of the fixed BAM by 5 dB. Last, the possibility of removing the training part for finding the parameters of adaptive BAMs for each individual was investigated. The results indicate that it is possible to use a predefined set of BAMs for all subjects and remove the training part completely. Moreover, the method is fast enough to be implemented for real-time application.

  12. HVS scheme for DICOM image compression: Design and comparative performance evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakar, B. [Biomedical and Engineering Division, Indian Institute of Technology Madras, Chennai 600036, Tamil Nadu (India)]. E-mail: prabhakarb@iitm.ac.in; Reddy, M. Ramasubba [Biomedical and Engineering Division, Indian Institute of Technology Madras, Chennai 600036, Tamil Nadu (India)

    2007-07-15

    Advanced digital imaging technology in medical domain demands efficient and effective DICOM image compression for progressive image transmission and picture archival. Here a compression system, which incorporates sensitivities of HVS coded with SPIHT quantization, is discussed. The weighting factors derived from luminance CSF are used to transform the wavelet subband coefficients to reflect characteristics of HVS in best possible manner. Mannos et al. and Daly HVS models have been used and results are compared. To evaluate the performance, Eskicioglu chart metric is considered. Experiment is done on both Monochrome and Color Dicom images of MRI, CT, OT, and CR, natural and benchmark images. Reconstructed image through our technique showed improvement in visual quality and Eskicioglu chart metric at same compression ratios. Also the Daly HVS model based compression shows better performance perceptually and quantitatively when compared to Mannos et el. model. Further 'bior4.4' wavelet filter provides better results than 'db9' filter for this compression system. Results give strong evidence that under common boundary conditions; our technique achieves competitive visual quality, compression ratio and coding/decoding time, when compared with jpeg2000 (kakadu)

  13. Compressible stability of growing boundary layers using parabolized stability equations

    Science.gov (United States)

    Chang, Chau-Lyan; Malik, Mujeeb R.; Erlebacher, Gordon; Hussaini, M. Y.

    1991-01-01

    The parabolized stability equation (PSE) approach is employed to study linear and nonlinear compressible stability with an eye to providing a capability for boundary-layer transition prediction in both 'quiet' and 'disturbed' environments. The governing compressible stability equations are solved by a rational parabolizing approximation in the streamwise direction. Nonparallel flow effects are studied for both the first- and second-mode disturbances. For oblique waves of the first-mode type, the departure from the parallel results is more pronounced as compared to that for the two-dimensional waves. Results for the Mach 4.5 case show that flow nonparallelism has more influence on the first mode than on the second. The disturbance growth rate is shown to be a strong function of the wall-normal distance due to either flow nonparallelism or nonlinear interactions. The subharmonic and fundamental types of breakdown are found to be similar to the ones in incompressible boundary layers.

  14. Compressive behavior of fine sand.

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Bradley E. (Air Force Research Laboratory, Eglin, FL); Kabir, Md. E. (Purdue University, West Lafayette, IN); Song, Bo; Chen, Wayne (Purdue University, West Lafayette, IN)

    2010-04-01

    The compressive mechanical response of fine sand is experimentally investigated. The strain rate, initial density, stress state, and moisture level are systematically varied. A Kolsky bar was modified to obtain uniaxial and triaxial compressive response at high strain rates. A controlled loading pulse allows the specimen to acquire stress equilibrium and constant strain-rates. The results show that the compressive response of the fine sand is not sensitive to strain rate under the loading conditions in this study, but significantly dependent on the moisture content, initial density and lateral confinement. Partially saturated sand is more compliant than dry sand. Similar trends were reported in the quasi-static regime for experiments conducted at comparable specimen conditions. The sand becomes stiffer as initial density and/or confinement pressure increases. The sand particle size become smaller after hydrostatic pressure and further smaller after dynamic axial loading.

  15. Compressibility of rotating black holes

    International Nuclear Information System (INIS)

    Dolan, Brian P.

    2011-01-01

    Interpreting the cosmological constant as a pressure, whose thermodynamically conjugate variable is a volume, modifies the first law of black hole thermodynamics. Properties of the resulting thermodynamic volume are investigated: the compressibility and the speed of sound of the black hole are derived in the case of nonpositive cosmological constant. The adiabatic compressibility vanishes for a nonrotating black hole and is maximal in the extremal case--comparable with, but still less than, that of a cold neutron star. A speed of sound v s is associated with the adiabatic compressibility, which is equal to c for a nonrotating black hole and decreases as the angular momentum is increased. An extremal black hole has v s 2 =0.9 c 2 when the cosmological constant vanishes, and more generally v s is bounded below by c/√(2).

  16. Cosmological Particle Data Compression in Practice

    Science.gov (United States)

    Zeyen, M.; Ahrens, J.; Hagen, H.; Heitmann, K.; Habib, S.

    2017-12-01

    In cosmological simulations trillions of particles are handled and several terabytes of unstructured particle data are generated in each time step. Transferring this data directly from memory to disk in an uncompressed way results in a massive load on I/O and storage systems. Hence, one goal of domain scientists is to compress the data before storing it to disk while minimizing the loss of information. To prevent reading back uncompressed data from disk, this can be done in an in-situ process. Since the simulation continuously generates data, the available time for the compression of one time step is limited. Therefore, the evaluation of compression techniques has shifted from only focusing on compression rates to include run-times and scalability.In recent years several compression techniques for cosmological data have become available. These techniques can be either lossy or lossless, depending on the technique. For both cases, this study aims to evaluate and compare the state of the art compression techniques for unstructured particle data. This study focuses on the techniques available in the Blosc framework with its multi-threading support, the XZ Utils toolkit with the LZMA algorithm that achieves high compression rates, and the widespread FPZIP and ZFP methods for lossy compressions.For the investigated compression techniques, quantitative performance indicators such as compression rates, run-time/throughput, and reconstruction errors are measured. Based on these factors, this study offers a comprehensive analysis of the individual techniques and discusses their applicability for in-situ compression. In addition, domain specific measures are evaluated on the reconstructed data sets, and the relative error rates and statistical properties are analyzed and compared. Based on this study future challenges and directions in the compression of unstructured cosmological particle data were identified.

  17. Compressive behavior of pervious concretes and a quantification of the influence of random pore structure features

    International Nuclear Information System (INIS)

    Deo, Omkar; Neithalath, Narayanan

    2010-01-01

    Research highlights: → Identified the relevant pore structure features of pervious concretes, provided methodologies to extract those, and quantified the influence of these features on compressive response. → A model for stress-strain relationship of pervious concretes, and relationship between model parameters and parameters of the stress-strain relationship developed. → Statistical model for compressive strength as a function of pore structure features; and a stochastic model for the sensitivity of pore structure features in strength prediction. - Abstract: Properties of a random porous material such as pervious concrete are strongly dependent on its pore structure features, porosity being an important one among them. This study deals with developing an understanding of the material structure-compressive response relationships in pervious concretes. Several pervious concrete mixtures with different pore structure features are proportioned and subjected to static compression tests. The pore structure features such as pore area fractions, pore sizes, mean free spacing of the pores, specific surface area, and the three-dimensional pore distribution density are extracted using image analysis methods. The compressive stress-strain response of pervious concretes, a model to predict the stress-strain response, and its relationship to several of the pore structure features are outlined. Larger aggregate sizes and increase in paste volume fractions are observed to result in increased compressive strengths. The compressive response is found to be influenced by the pore sizes, their distributions and spacing. A statistical model is used to relate the compressive strength to the relevant pore structure features, which is then used as a base model in a Monte-Carlo simulation to evaluate the sensitivity of the predicted compressive strength to the model terms.

  18. Plasmons in strong superconductors

    International Nuclear Information System (INIS)

    Baldo, M.; Ducoin, C.

    2011-01-01

    We present a study of the possible plasmon excitations that can occur in systems where strong superconductivity is present. In these systems the plasmon energy is comparable to or smaller than the pairing gap. As a prototype of these systems we consider the proton component of Neutron Star matter just below the crust when electron screening is not taken into account. For the realistic case we consider in detail the different aspects of the elementary excitations when the proton, electron components are considered within the Random-Phase Approximation generalized to the superfluid case, while the influence of the neutron component is considered only at qualitative level. Electron screening plays a major role in modifying the proton spectrum and spectral function. At the same time the electron plasmon is strongly modified and damped by the indirect coupling with the superfluid proton component, even at moderately low values of the gap. The excitation spectrum shows the interplay of the different components and their relevance for each excitation modes. The results are relevant for neutrino physics and thermodynamical processes in neutron stars. If electron screening is neglected, the spectral properties of the proton component show some resemblance with the physical situation in high-T c superconductors, and we briefly discuss similarities and differences in this connection. In a general prospect, the results of the study emphasize the role of Coulomb interaction in strong superconductors.

  19. Compressed sensing & sparse filtering

    CERN Document Server

    Carmi, Avishy Y; Godsill, Simon J

    2013-01-01

    This book is aimed at presenting concepts, methods and algorithms ableto cope with undersampled and limited data. One such trend that recently gained popularity and to some extent revolutionised signal processing is compressed sensing. Compressed sensing builds upon the observation that many signals in nature are nearly sparse (or compressible, as they are normally referred to) in some domain, and consequently they can be reconstructed to within high accuracy from far fewer observations than traditionally held to be necessary. Apart from compressed sensing this book contains other related app

  20. zlib compression library

    OpenAIRE

    Gailly, Jean-loup; Adler, Mark

    2004-01-01

    (taken from http://www.gzip.org/ on 2004-12-01) zlib is designed to be a free, general-purpose, legally unencumbered -- that is, not covered by any patents -- lossless data-compression library for use on virtually any computer hardware and operating system. The zlib data format is itself portable across platforms. Unlike the LZW compression method used in Unix compress(1) and in the GIF image format, the compression method currently used in zlib essentially never expands the data. (LZW ca...

  1. Early sheath removal after percutaneous coronary intervention using Assiut Femoral Compression Device is feasible and safe. Results of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Ayman K.M. Hassan

    2015-03-01

    Conclusion: Our results indicate that AFCD2 is a simple and effective alternative to MC for hemostasis following PCI. Early sheath removal 2 h post PCI is feasible, safe, and improves the patient’s comfort.

  2. Interactive calculation procedures for mixed compression inlets

    Science.gov (United States)

    Reshotko, Eli

    1983-01-01

    The proper design of engine nacelle installations for supersonic aircraft depends on a sophisticated understanding of the interactions between the boundary layers and the bounding external flows. The successful operation of mixed external-internal compression inlets depends significantly on the ability to closely control the operation of the internal compression portion of the inlet. This portion of the inlet is one where compression is achieved by multiple reflection of oblique shock waves and weak compression waves in a converging internal flow passage. However weak these shocks and waves may seem gas-dynamically, they are of sufficient strength to separate a laminar boundary layer and generally even strong enough for separation or incipient separation of the turbulent boundary layers. An understanding was developed of the viscous-inviscid interactions and of the shock wave boundary layer interactions and reflections.

  3. Compression of Probabilistic XML documents

    NARCIS (Netherlands)

    Veldman, Irma

    2009-01-01

    Probabilistic XML (PXML) files resulting from data integration can become extremely large, which is undesired. For XML there are several techniques available to compress the document and since probabilistic XML is in fact (a special form of) XML, it might benefit from these methods even more. In

  4. Force balancing in mammographic compression

    NARCIS (Netherlands)

    Branderhorst, W.; de Groot, J. E.; Neeter, L. M. F. H.; van Lier, M. G. J. T. B.; Neeleman, C.; den Heeten, G. J.; Grimbergen, C. A.

    2016-01-01

    In mammography, the height of the image receptor is adjusted to the patient before compressing the breast. An inadequate height setting can result in an imbalance between the forces applied by the image receptor and the paddle, causing the clamped breast to be pushed up or down relative to the body

  5. The power and the pain: Mammographic compression research from the service-users' perspective

    International Nuclear Information System (INIS)

    Robinson, Leslie; Hogg, Peter; Newton-Hughes, Ann

    2013-01-01

    Purpose: to explore the value service-users can add to our understanding of inter-practitioner compression variability in mammography. Imaging of the breast for the screening and detection of breast carcinoma is generally carried out by mammographic examination the technique for which includes compression of the breast. Evolving research calls into question compression practice in terms of practitioner consistency thus raising the possibility that strong compression may not be required. We were interested to know whether this was important to service-users and if such knowledge might influence their behaviour. Methods: and sample: A qualitative study involving 3 focus groups interviews (n = 4, 6 and 5). Participants were first asked to reflect on their own experiences of breast compression within the context of a breast screening examination, then interpret the results of the evolving research detailed above. We then explored whether these participants might behave differently during future mammography in light being appraised of these research findings. Results: A grounded approach was used to analyse the data into themes. The two overarching themes were i) Service-User Empowerment, which illustrates the difficulties participants believe women would encounter in exercising power in the breast screening mammographic examination; and ii) Service User Experience of Mammography, which unearthed unanticipated aspects of the examination, other than compression, that contribute to pain and discomfort and which therefore need investigation. Conclusion: Involving service-users more collaboratively in research can help investigators understand the impact of their work and highlight patient-relevant areas for further investigation

  6. BENEFITS AND CHALLENGES OF VARIABLE COMPRESSION RATIO AT DIESEL ENGINES

    OpenAIRE

    Radivoje B Pešić; Saša T Milojević; Stevan P Veinović

    2010-01-01

    The compression ratio strongly affects the working process and provides an exceptional degree of control over engine performance. In conventional internal combustion engines, the compression ratio is fixed and their performance is therefore a compromise between conflicting requirements. One fundamental problem is that drive units in the vehicles must successfully operate at variable speeds and loads and in different ambient conditions. If a diesel engine has a fixed compression ratio, a minim...

  7. Resultados de tratamento cirúrgico da pseudoartrose de fratura diafisária do úmero com placa de compressão dinâmica e enxerto de osso esponjoso Results of surgical treatment of nonunion of humeral shaft fracture with dynamic compression plate and cancellous bone grafting

    Directory of Open Access Journals (Sweden)

    Olasinde Anthony Ayotunde

    2012-01-01

    Full Text Available OBJETIVO: Avaliamos o tratamento da pseudoartrose de fratura diafisária do úmero com placa de compressão dinâmica de janeiro de 2002 a dezembro de 2009. MÉTODOS: Vinte e dois pacientes foram tratados durante o período do estudo. O trauma foi a causa predominante de lesão em 86,4% dos pacientes. RESULTADOS: A pseudoartrose foi atrófica em 81,8% e hipertrófica em 18,2% dos indivíduos. Havia lesão primária do nervo radial nervo em 27,3% dos pacientes. Todos os participantes tinham fratura fechada à apresentação e 81,2% deles tinham recebido tratamento anterior de traditional bone setters (pessoa que faz a redução de ossos quebrados ou deslocados, geralmente sem ser médico licenciado e 18,8% tinham falha do tratamento conservador com gesso. O tempo médio até a união foi 16 semanas. O tratamento anterior com traditional bone setters afetou significantemente o tempo de consolidação da fratura (p OBJECTIVE: We evaluated the treatment of nonunion of humeral shaft fracture with dynamic compression plate from January 2002 to December 2009. METHODS: Twenty two patients were treated over the study period. Trauma was the predominant cause of injury in 86,4% of the patients. RESULTS: Nonunion was atrophic in 81,8% and hypertrophic in 18,2% of the individuals. There was a primary injury of the radial nerve in 27,3% of the patients. All the participants had closed fracture at presentation, and 81,2% had received previous treatment from traditional bone setters and 18,8% had failure of the conservative cast management.The average time to healing was 16 weeks. Previous treatment from traditional bone setters significantly affected the time to fracture healing (p<0,05. All fractures had successful union. CONCLUSION: It was concluded that dynamic compression plating remains an effective treatment option for nonunion of humeral shaft fracture. Level of Evidence III, Retrospective study.

  8. Expression of SOST/sclerostin in compressed periodontal ligament cells

    Directory of Open Access Journals (Sweden)

    Masae Ueda

    2016-09-01

    Conclusion: These results indicate that PDL cells subjected to light compressive force exhibit increased expression of SOST/sclerostin, which inhibits bone formation on the compressed side during orthodontic tooth movement.

  9. Compressed Sensing Based Fingerprint Identification for Wireless Transmitters

    Directory of Open Access Journals (Sweden)

    Caidan Zhao

    2014-01-01

    Full Text Available Most of the existing fingerprint identification techniques are unable to distinguish different wireless transmitters, whose emitted signals are highly attenuated, long-distance propagating, and of strong similarity to their transient waveforms. Therefore, this paper proposes a new method to identify different wireless transmitters based on compressed sensing. A data acquisition system is designed to capture the wireless transmitter signals. Complex analytical wavelet transform is used to obtain the envelope of the transient signal, and the corresponding features are extracted by using the compressed sensing theory. Feature selection utilizing minimum redundancy maximum relevance (mRMR is employed to obtain the optimal feature subsets for identification. The results show that the proposed method is more efficient for the identification of wireless transmitters with similar transient waveforms.

  10. Interactive computer graphics applications for compressible aerodynamics

    Science.gov (United States)

    Benson, Thomas J.

    1994-01-01

    Three computer applications have been developed to solve inviscid compressible fluids problems using interactive computer graphics. The first application is a compressible flow calculator which solves for isentropic flow, normal shocks, and oblique shocks or centered expansions produced by two dimensional ramps. The second application couples the solutions generated by the first application to a more graphical presentation of the results to produce a desk top simulator of three compressible flow problems: 1) flow past a single compression ramp; 2) flow past two ramps in series; and 3) flow past two opposed ramps. The third application extends the results of the second to produce a design tool which solves for the flow through supersonic external or mixed compression inlets. The applications were originally developed to run on SGI or IBM workstations running GL graphics. They are currently being extended to solve additional types of flow problems and modified to operate on any X-based workstation.

  11. Anisotropic Concrete Compressive Strength

    DEFF Research Database (Denmark)

    Gustenhoff Hansen, Søren; Jørgensen, Henrik Brøner; Hoang, Linh Cao

    2017-01-01

    When the load carrying capacity of existing concrete structures is (re-)assessed it is often based on compressive strength of cores drilled out from the structure. Existing studies show that the core compressive strength is anisotropic; i.e. it depends on whether the cores are drilled parallel...

  12. Strong-coupling approximations

    International Nuclear Information System (INIS)

    Abbott, R.B.

    1984-03-01

    Standard path-integral techniques such as instanton calculations give good answers for weak-coupling problems, but become unreliable for strong-coupling. Here we consider a method of replacing the original potential by a suitably chosen harmonic oscillator potential. Physically this is motivated by the fact that potential barriers below the level of the ground-state energy of a quantum-mechanical system have little effect. Numerically, results are good, both for quantum-mechanical problems and for massive phi 4 field theory in 1 + 1 dimensions. 9 references, 6 figures

  13. Compression Behavior of High Performance Polymeric Fibers

    National Research Council Canada - National Science Library

    Kumar, Satish

    2003-01-01

    Hydrogen bonding has proven to be effective in improving the compressive strength of rigid-rod polymeric fibers without resulting in a decrease in tensile strength while covalent crosslinking results in brittle fibers...

  14. Optical properties of highly compressed polystyrene: An ab initio study

    Science.gov (United States)

    Hu, S. X.; Collins, L. A.; Colgan, J. P.; Goncharov, V. N.; Kilcrease, D. P.

    2017-10-01

    Using all-electron density functional theory, we have performed an ab initio study on x-ray absorption spectra of highly compressed polystyrene (CH). We found that the K -edge shifts in strongly coupled, degenerate polystyrene cannot be explained by existing continuum-lowering models adopted in traditional plasma physics. To gain insights into the K -edge shift in warm, dense CH, we have developed a model designated as "single mixture in a box" (SMIAB), which incorporates both the lowering of the continuum and the rising of the Fermi surface resulting from high compression. This simple SMIAB model correctly predicts the K -edge shift of carbon in highly compressed CH in good agreement with results from quantum molecular dynamics (QMD) calculations. Traditional opacity models failed to give the proper K -edge shifts as the CH density increased. Based on QMD calculations, we have established a first-principles opacity table (FPOT) for CH in a wide range of densities and temperatures [ρ =0.1 -100 g /c m3 and T =2000 -1 000 000 K ]. The FPOT gives much higher Rosseland mean opacity compared to the cold-opacity-patched astrophysics opacity table for warm, dense CH and favorably compares to the newly improved Los Alamos atomic model for moderately compressed CH (ρCH≤10 g /c m3 ), but remains a factor of 2 to 3 higher at extremely high densities (ρCH≥50 g /c m3 ). We anticipate the established FPOT of CH will find important applications to reliable designs of high-energy-density experiments. Moreover, the understanding of K -edge shifting revealed in this study could provide guides for improving the traditional opacity models to properly handle the strongly coupled and degenerate conditions.

  15. Theory of third sound in a compressible and layered superfluid

    International Nuclear Information System (INIS)

    Puff, R.D.; Dash, J.G.

    1980-01-01

    This paper examines the theory of third sound, without attenuation effects, in layered superfluid films with finite compressibility. This theory, together with the application of a simple thermodynamic model for the film layers shows how the third-sound velocity can undergo strong variations with coverage associated with progressive changes in film compressibility, in-layer phase changes, and layer completion

  16. Simulation of breast compression in mammography using finite element analysis: A preliminary study

    Science.gov (United States)

    Liu, Yan-Lin; Liu, Pei-Yuan; Huang, Mei-Lan; Hsu, Jui-Ting; Han, Ruo-Ping; Wu, Jay

    2017-11-01

    Adequate compression during mammography lowers the absorbed dose in the breast and improves the image quality. The compressed breast thickness (CBT) is affected by various factors, such as breast volume, glandularity, and compression force. In this study, we used the finite element analysis to simulate breast compression and deformation and validated the simulated CBT with clinical mammography results. Image data from ten subjects who had undergone mammography screening and breast magnetic resonance imaging (MRI) were collected, and their breast models were created according to the MR images. The non-linear tissue deformation under 10-16 daN in the cranial-caudal direction was simulated. When the clinical compression force was used, the simulated CBT ranged from 2.34 to 5.90 cm. The absolute difference between the simulated CBT and the clinically measured CBT ranged from 0.5 to 7.1 mm. The simulated CBT had a strong positive linear relationship to breast volume and a weak negative correlation to glandularity. The average simulated CBT under 10, 12, 14, and 16 daN was 5.68, 5.12, 4.67, and 4.25 cm, respectively. Through this study, the relationships between CBT, breast volume, glandularity, and compression force are provided for use in clinical mammography.

  17. STRONG SOLAR WIND DYNAMIC PRESSURE PULSES: INTERPLANETARY SOURCES AND THEIR IMPACTS ON GEOSYNCHRONOUS MAGNETIC FIELDS

    International Nuclear Information System (INIS)

    Zuo, Pingbing; Feng, Xueshang; Wang, Yi; Xie, Yanqiong; Xu, Xiaojun

    2015-01-01

    In this investigation, we first present a statistical result of the interplanetary sources of very strong solar wind dynamic pressure pulses (DPPs) detected by WIND during solar cycle 23. It is found that the vast majority of strong DPPs reside within solar wind disturbances. Although the variabilities of geosynchronous magnetic fields (GMFs) due to the impact of positive DPPs have been well established, there appears to be no systematic investigations on the response of GMFs to negative DPPs. Here, we study both the decompression effects of very strong negative DPPs and the compression from strong positive DPPs on GMFs at different magnetic local time sectors. In response to the decompression of strong negative DPPs, GMFs on the dayside near dawn and near dusk on the nightside, are generally depressed. But near the midnight region, the responses of GMF are very diverse, being either positive or negative. For part of the events when GOES is located at the midnight sector, the GMF is found to abnormally increase as the result of magnetospheric decompression caused by negative DPPs. It is known that under certain conditions magnetic depression of nightside GMFs can be caused by the impact of positive DPPs. Here, we find that a stronger pressure enhancement may have a higher probability of producing the exceptional depression of GMF at the midnight region. Statistically, both the decompression effect of strong negative DPPs and the compression effect of strong positive DPPs depend on the magnetic local time, which are stronger at the noon sector

  18. Compression therapy after ankle fracture surgery

    DEFF Research Database (Denmark)

    Winge, R; Bayer, L; Gottlieb, H

    2017-01-01

    PURPOSE: The main purpose of this systematic review was to investigate the effect of compression treatment on the perioperative course of ankle fractures and describe its effect on edema, pain, ankle joint mobility, wound healing complication, length of stay (LOS) and time to surgery (TTS). The aim...... was to suggest a recommendation to clinicians considering implementing compression therapy in the standard care of the ankle fracture patient, based on the existing literature. METHODS: We conducted a systematic search of literature including studies concerning adult patients with unstable ankle fractures...... undergoing surgery, testing either intermittent pneumatic compression, compression bandage and/or compression stocking and reporting its effect on edema, pain, ankle joint mobility, wound healing complication, LOS and TTS. To conclude on data a narrative synthesis was performed. RESULTS: The review included...

  19. Compressive Fracture of Brittle Geomaterial: Fractal Features of Compression-Induced Fracture Surfaces and Failure Mechanism

    Directory of Open Access Journals (Sweden)

    L. Ren

    2014-01-01

    Full Text Available Compressive fracture is one of the most common failure patterns in geotechnical engineering. For better understanding of the local failure mechanism of compressive fractures of brittle geomaterials, three compressive fracture tests were conducted on sandstone. Edge cracked semicircular bend specimens were used and, consequently, fresh and unfilled compressive fracture surfaces were obtained. A laser profilometer was employed to measure the topography of each rough fracture surface, followed by fractal analysis of the irregularities of the obtained compression-induced fracture surfaces using the cubic cover method. To carry out a contrastive analysis with the results of compressive fracture tests, three tension mode fracture tests were also conducted and the fractal features of the obtained fracture surfaces were determined. The obtained average result of the fractal dimensions of the compression-induced surfaces was 2.070, whereas the average result was 2.067 for the tension-induced fracture surfaces. No remarkable differences between the fractal dimensions of the compression-induced and tension-induced fracture surfaces may indicate that compressive fracture may occur, at least on the investigative scale of this work, in a similar manner to tension fracture.

  20. TEXT COMPRESSION ALGORITHMS - A COMPARATIVE STUDY

    Directory of Open Access Journals (Sweden)

    S. Senthil

    2011-12-01

    Full Text Available Data Compression may be defined as the science and art of the representation of information in a crisply condensed form. For decades, Data compression has been one of the critical enabling technologies for the ongoing digital multimedia revolution. There are a lot of data compression algorithms which are available to compress files of different formats. This paper provides a survey of different basic lossless data compression algorithms. Experimental results and comparisons of the lossless compression algorithms using Statistical compression techniques and Dictionary based compression techniques were performed on text data. Among the Statistical coding techniques, the algorithms such as Shannon-Fano Coding, Huffman coding, Adaptive Huffman coding, Run Length Encoding and Arithmetic coding are considered. Lempel Ziv scheme which is a dictionary based technique is divided into two families: one derived from LZ77 (LZ77, LZSS, LZH, LZB and LZR and the other derived from LZ78 (LZ78, LZW, LZFG, LZC and LZT. A set of interesting conclusions are derived on this basis.

  1. Radiation-induced disorder in compressed lanthanide zirconates.

    Science.gov (United States)

    Park, Sulgiye; Tracy, Cameron L; Zhang, Fuxiang; Park, Changyong; Trautmann, Christina; Tkachev, Sergey N; Lang, Maik; Mao, Wendy L; Ewing, Rodney C

    2018-02-28

    The effects of swift heavy ion irradiation-induced disordering on the behavior of lanthanide zirconate compounds (Ln 2 Zr 2 O 7 where Ln = Sm, Er, or Nd) at high pressures are investigated. After irradiation with 2.2 GeV 197 Au ions, the initial ordered pyrochlore structure (Fd3[combining macron]m) transformed to a defect-fluorite structure (Fm3[combining macron]m) in Sm 2 Zr 2 O 7 and Nd 2 Zr 2 O 7 . For irradiated Er 2 Zr 2 O 7 , which has a defect-fluorite structure, ion irradiation induces local disordering by introducing Frenkel defects despite retention of the initial structure. When subjected to high pressures (>29 GPa) in the absence of irradiation, all of these compounds transform to a cotunnite-like (Pnma) phase, followed by sluggish amorphization with further compression. However, if these compounds are irradiated prior to compression, the high pressure cotunnite-like phase is not formed. Rather, they transform directly from their post-irradiation defect-fluorite structure to an amorphous structure upon compression (>25 GPa). Defects and disordering induced by swift heavy ion irradiation alter the transformation pathways by raising the energetic barriers for the transformation to the high pressure cotunnite-like phase, rendering it inaccessible. As a result, the high pressure stability field of the amorphous phase is expanded to lower pressures when irradiation is coupled with compression. The responses of materials in the lanthanide zirconate system to irradiation and compression, both individually and in tandem, are strongly influenced by the specific lanthanide composition, which governs the defect energetics at extreme conditions.

  2. Testing framework for compression methods

    OpenAIRE

    Štoček, Ondřej

    2008-01-01

    There are many algorithms for data compression. These compression methods often achieve different compression rate and also use computer resources differently. In practice a combination of compression is usually used instead of standalone compression methods. The software tool can be evolved, where we can easily combine existing compression methods to new one and test it consequently. Main goal of this work is to propound such tool and implement it. Further goal is to implement basic library ...

  3. Variations in Compressive Strength of Geopolymer due to the CaO Added Fly Ash

    Science.gov (United States)

    Zhao, Yuqing; Koumoto, Tatsuya; Kondo, Fumiyoshi

    Recently, geopolymer has been a noteworthy material which can be used as a replacement for portland cement. The mechanical characteristics and consistency of the geopolymer are strongly affected by its chemical components of fly ash. The variations in compressive strength of geopolymer due to the CaO added fly ash were investigated in this paper. The compressive strengths of geopolymer were increased with an increase in the curing period, and the characteristics changed from the one of plastic soil material to brittle material such as concrete, regardless of CaO content. Also, the results of compressive strength and modulus of deformation showed their maximum value in the case of 8-10% CaO content. From this result, the maximum characteristics of the strengths were assumed to be exerted in case which the water draining process of geopolymer was balanced with the water absorbing process of additional CaO.

  4. Testing strong interaction theories

    International Nuclear Information System (INIS)

    Ellis, J.

    1979-01-01

    The author discusses possible tests of the current theories of the strong interaction, in particular, quantum chromodynamics. High energy e + e - interactions should provide an excellent means of studying the strong force. (W.D.L.)

  5. Close covalent contacts: gauging molecular compression in a molecular compression chamber.

    Science.gov (United States)

    Berstis, Laura; Siegel, Jay S; Baldridge, Kim K

    2014-01-28

    A computational investigation is carried out on a 3-fold symmetric model molecular compression chamber comprising two triply-bridged triptycenes with variable endo-pointing substituents. Assessment of the strain of the constant scaffold serves to gauge the compression stress across variable interaction partners at unusually short C-X distance, and creates a transferable knowledge base for the design of molecules with close contacts due to bond length compression. Results motivate ideas in the design of more effective molecular compression chambers and their realization through chemical synthesis.

  6. Observer Performance Measured against Hybrid Compressed Video Imagery.

    Science.gov (United States)

    1981-03-01

    reductions on target detection and recognition were measulred. A hybrid DCT/ DPCM compression algorithm was used to manipulate the bit-per-pixel...pulse code modulation ( DPCM ) encoding of the resulting frequency coefficients to achieve intraframe compression. One of the greatest concerns of... DPCM compression algorithm which will be used in the MICNS communi- cations link. This facility was used to compress a subset of the imagery used in the

  7. High-quality lossy compression: current and future trends

    Science.gov (United States)

    McLaughlin, Steven W.

    1995-01-01

    This paper is concerned with current and future trends in the lossy compression of real sources such as imagery, video, speech and music. We put all lossy compression schemes into common framework where each can be characterized in terms of three well-defined advantages: cell shape, region shape and memory advantages. We concentrate on image compression and discuss how new entropy constrained trellis-based compressors achieve cell- shape, region-shape and memory gain resulting in high fidelity and high compression.

  8. Advanced inference in fuzzy systems by rule base compression

    OpenAIRE

    Gegov, Alexander; Gobalakrishnan, N.

    2007-01-01

    This paper describes a method for rule base compression of fuzzy systems. The method compresses a fuzzy system with an arbitrarily large number of rules into a smaller fuzzy system by removing the redundancy in the fuzzy rule base. As a result of this compression, the number of on-line operations during the fuzzy inference process is significantly reduced without compromising the solution. This rule base compression method outperforms significantly other known methods for fuzzy rule base redu...

  9. Radio frequency pulse compression

    International Nuclear Information System (INIS)

    Farkas, Z.D.

    1988-12-01

    High gradients require peak powers. One possible way to generate high peak powers is to generate a relatively long pulse at a relatively low power and compress it into a shorter pulse with higher peak power. It is possible to compress before dc to rf conversion as is done for the relativistic klystron or after dc to rf conversion as is done with SLED. In this note only radio frequency pulse compression (RFPC) is considered. Three methods of RFPC will be discussed: SLED, BEC, and REC. 3 refs., 8 figs., 1 tab

  10. Recognizable or Not: Towards Image Semantic Quality Assessment for Compression

    Science.gov (United States)

    Liu, Dong; Wang, Dandan; Li, Houqiang

    2017-12-01

    Traditionally, image compression was optimized for the pixel-wise fidelity or the perceptual quality of the compressed images given a bit-rate budget. But recently, compressed images are more and more utilized for automatic semantic analysis tasks such as recognition and retrieval. For these tasks, we argue that the optimization target of compression is no longer perceptual quality, but the utility of the compressed images in the given automatic semantic analysis task. Accordingly, we propose to evaluate the quality of the compressed images neither at pixel level nor at perceptual level, but at semantic level. In this paper, we make preliminary efforts towards image semantic quality assessment (ISQA), focusing on the task of optical character recognition (OCR) from compressed images. We propose a full-reference ISQA measure by comparing the features extracted from text regions of original and compressed images. We then propose to integrate the ISQA measure into an image compression scheme. Experimental results show that our proposed ISQA measure is much better than PSNR and SSIM in evaluating the semantic quality of compressed images; accordingly, adopting our ISQA measure to optimize compression for OCR leads to significant bit-rate saving compared to using PSNR or SSIM. Moreover, we perform subjective test about text recognition from compressed images, and observe that our ISQA measure has high consistency with subjective recognizability. Our work explores new dimensions in image quality assessment, and demonstrates promising direction to achieve higher compression ratio for specific semantic analysis tasks.

  11. Using autoencoders for mammogram compression.

    Science.gov (United States)

    Tan, Chun Chet; Eswaran, Chikkannan

    2011-02-01

    This paper presents the results obtained for medical image compression using autoencoder neural networks. Since mammograms (medical images) are usually of big sizes, training of autoencoders becomes extremely tedious and difficult if the whole image is used for training. We show in this paper that the autoencoders can be trained successfully by using image patches instead of the whole image. The compression performances of different types of autoencoders are compared based on two parameters, namely mean square error and structural similarity index. It is found from the experimental results that the autoencoder which does not use Restricted Boltzmann Machine pre-training yields better results than those which use this pre-training method.

  12. Performance Evaluation of Data Compression Systems Applied to Satellite Imagery

    Directory of Open Access Journals (Sweden)

    Lilian N. Faria

    2012-01-01

    Full Text Available Onboard image compression systems reduce the data storage and downlink bandwidth requirements in space missions. This paper presents an overview and evaluation of some compression algorithms suitable for remote sensing applications. Prediction-based compression systems, such as DPCM and JPEG-LS, and transform-based compression systems, such as CCSDS-IDC and JPEG-XR, were tested over twenty multispectral (5-band images from CCD optical sensor of the CBERS-2B satellite. Performance evaluation of these algorithms was conducted using both quantitative rate-distortion measurements and subjective image quality analysis. The PSNR, MSSIM, and compression ratio results plotted in charts and the SSIM maps are used for comparison of quantitative performance. Broadly speaking, the lossless JPEG-LS outperforms other lossless compression schemes, and, for lossy compression, JPEG-XR can provide lower bit rate and better tradeoff between compression ratio and image quality.

  13. Isostatic compression of buffer blocks. Middle scale

    International Nuclear Information System (INIS)

    Ritola, J.; Pyy, E.

    2012-01-01

    Manufacturing of buffer components using isostatic compression method has been studied in small scale in 2008 (Laaksonen 2010). These tests included manufacturing of buffer blocks using different bentonite materials and different compression pressures. Isostatic mould technology was also tested, along with different methods to fill the mould, such as vibration and partial vacuum, as well as a stepwise compression of the blocks. The development of manufacturing techniques has continued with small-scale (30 %) blocks (diameter 600 mm) in 2009. This was done in a separate project: Isostatic compression, manufacturing and testing of small scale (D = 600 mm) buffer blocks. The research on the isostatic compression method continued in 2010 in a project aimed to test and examine the isostatic manufacturing process of buffer blocks at 70 % scale (block diameter 1200 to 1300 mm), and the aim was to continue in 2011 with full-scale blocks (diameter 1700 mm). A total of nine bentonite blocks were manufactured at 70 % scale, of which four were ring-shaped and the rest were cylindrical. It is currently not possible to manufacture full-scale blocks, because there is no sufficiently large isostatic press available. However, such a compression unit is expected to be possible to use in the near future. The test results of bentonite blocks, produced with an isostatic pressing method at different presses and at different sizes, suggest that the technical characteristics, for example bulk density and strength values, are somewhat independent of the size of the block, and that the blocks have fairly homogenous characteristics. Water content and compression pressure are the two most important properties determining the characteristics of the compressed blocks. By adjusting these two properties it is fairly easy to produce blocks at a desired density. The commonly used compression pressure in the manufacturing of bentonite blocks is 100 MPa, which compresses bentonite to approximately

  14. Isostatic compression of buffer blocks. Middle scale

    Energy Technology Data Exchange (ETDEWEB)

    Ritola, J.; Pyy, E. [VTT Technical Research Centre of Finland, Espoo (Finland)

    2012-01-15

    Manufacturing of buffer components using isostatic compression method has been studied in small scale in 2008 (Laaksonen 2010). These tests included manufacturing of buffer blocks using different bentonite materials and different compression pressures. Isostatic mould technology was also tested, along with different methods to fill the mould, such as vibration and partial vacuum, as well as a stepwise compression of the blocks. The development of manufacturing techniques has continued with small-scale (30 %) blocks (diameter 600 mm) in 2009. This was done in a separate project: Isostatic compression, manufacturing and testing of small scale (D = 600 mm) buffer blocks. The research on the isostatic compression method continued in 2010 in a project aimed to test and examine the isostatic manufacturing process of buffer blocks at 70 % scale (block diameter 1200 to 1300 mm), and the aim was to continue in 2011 with full-scale blocks (diameter 1700 mm). A total of nine bentonite blocks were manufactured at 70 % scale, of which four were ring-shaped and the rest were cylindrical. It is currently not possible to manufacture full-scale blocks, because there is no sufficiently large isostatic press available. However, such a compression unit is expected to be possible to use in the near future. The test results of bentonite blocks, produced with an isostatic pressing method at different presses and at different sizes, suggest that the technical characteristics, for example bulk density and strength values, are somewhat independent of the size of the block, and that the blocks have fairly homogenous characteristics. Water content and compression pressure are the two most important properties determining the characteristics of the compressed blocks. By adjusting these two properties it is fairly easy to produce blocks at a desired density. The commonly used compression pressure in the manufacturing of bentonite blocks is 100 MPa, which compresses bentonite to approximately

  15. Crypto-Compression Using TEA's Algorithm and a RLC Compression

    OpenAIRE

    Borie , Jean-Claude; Puech , William; Dumas , Michel

    2004-01-01

    International audience; In this paper, we discuss the secure of transfering of medical images. We propose two cryptosystems, the first one is a very fast algorithm by block, the TEA (Tiny Encryption Algo- rithm) and the second is a stream cipher based on Vigenere’s ciphering. We show differences existing between them, especially concerning the combination of the image encryption and the compression. Results applied to medical images are given to illustrate the two methods.; Dans cet article, ...

  16. Compressed Video Segmentation

    National Research Council Canada - National Science Library

    Kobla, Vikrant; Doermann, David S; Rosenfeld, Azriel

    1996-01-01

    ... changes in content and camera motion. The analysis is performed in the compressed domain using available macroblock and motion vector information, and if necessary, discrete cosine transform (DCT) information...

  17. Mechanical chest compressions.

    Science.gov (United States)

    Pomeroy, Matthew

    2012-09-13

    The authors of this study state that there is a lack of evidence about the efficiency of mechanical devices in producing chest compressions as an adjunct to resuscitation during cardiorespiratory arrest.

  18. Biaxial compression test technique

    Science.gov (United States)

    Hansard, E. T.

    1975-01-01

    Fixture and technique have been developed for predicting behavior of stiffened skin panels under biaxial compressive loading. Tester can load test panel independently in longitudinal and transverse directions. Data can also be obtained in combined mode.

  19. Muon cooling: longitudinal compression.

    Science.gov (United States)

    Bao, Yu; Antognini, Aldo; Bertl, Wilhelm; Hildebrandt, Malte; Khaw, Kim Siang; Kirch, Klaus; Papa, Angela; Petitjean, Claude; Piegsa, Florian M; Ritt, Stefan; Sedlak, Kamil; Stoykov, Alexey; Taqqu, David

    2014-06-06

    A 10  MeV/c positive muon beam was stopped in helium gas of a few mbar in a magnetic field of 5 T. The muon "swarm" has been efficiently compressed from a length of 16 cm down to a few mm along the magnetic field axis (longitudinal compression) using electrostatic fields. The simulation reproduces the low energy interactions of slow muons in helium gas. Phase space compression occurs on the order of microseconds, compatible with the muon lifetime of 2  μs. This paves the way for the preparation of a high-quality low-energy muon beam, with an increase in phase space density relative to a standard surface muon beam of 10^{7}. The achievable phase space compression by using only the longitudinal stage presented here is of the order of 10^{4}.

  20. Deterministic Compressed Sensing

    Science.gov (United States)

    2011-11-01

    programs. Examples of such algorithms are the interior point methods [51, 52], Lasso modification to LARS [106, 171], homotopy methods [99], weighted...component analysis . IEEE Signal Processing Letters, 9(2):40–42, 2002. [171] S. J. Kim, K. Koh, M. Lustig, S. Boyd, and D. Gorinevsky. A method for...53 7.3 Analysis of the GAME Algorithm . . . . . . . . . . . . . . . . . . . . 57 III Expander-Based Compressed Sensing 61 8 Efficient Compressed

  1. Blind Compressed Sensing

    OpenAIRE

    Gleichman, Sivan; Eldar, Yonina C.

    2011-01-01

    The fundamental principle underlying compressed sensing is that a signal, which is sparse under some basis representation, can be recovered from a small number of linear measurements. However, prior knowledge of the sparsity basis is essential for the recovery process. This work introduces the concept of blind compressed sensing, which avoids the need to know the sparsity basis in both the sampling and the recovery process. We suggest three possible constraints on the sparsity basis that can ...

  2. LIGO: The strong belief

    CERN Multimedia

    Antonella Del Rosso

    2016-01-01

    Twenty years of designing, building and testing a number of innovative technologies, with the strong belief that the endeavour would lead to a historic breakthrough. The Bulletin publishes an abstract of the Courier’s interview with Barry Barish, one of the founding fathers of LIGO.   The plots show the signals of gravitational waves detected by the twin LIGO observatories at Livingston, Louisiana, and Hanford, Washington. (Image: Caltech/MIT/LIGO Lab) On 11 February, the Laser Interferometer Gravitational-Wave Observatory (LIGO) and Virgo collaborations published a historic paper in which they showed a gravitational signal emitted by the merger of two black holes. These results come after 20 years of hard work by a large collaboration of scientists operating the two LIGO observatories in the US. Barry Barish, Linde Professor of Physics, Emeritus at the California Institute of Technology and former Director of the Global Design Effort for the Internat...

  3. Optimization of Error-Bounded Lossy Compression for Hard-to-Compress HPC Data

    Energy Technology Data Exchange (ETDEWEB)

    Di, Sheng; Cappello, Franck

    2018-01-01

    Since today’s scientific applications are producing vast amounts of data, compressing them before storage/transmission is critical. Results of existing compressors show two types of HPC data sets: highly compressible and hard to compress. In this work, we carefully design and optimize the error-bounded lossy compression for hard-tocompress scientific data. We propose an optimized algorithm that can adaptively partition the HPC data into best-fit consecutive segments each having mutually close data values, such that the compression condition can be optimized. Another significant contribution is the optimization of shifting offset such that the XOR-leading-zero length between two consecutive unpredictable data points can be maximized. We finally devise an adaptive method to select the best-fit compressor at runtime for maximizing the compression factor. We evaluate our solution using 13 benchmarks based on real-world scientific problems, and we compare it with 9 other state-of-the-art compressors. Experiments show that our compressor can always guarantee the compression errors within the user-specified error bounds. Most importantly, our optimization can improve the compression factor effectively, by up to 49% for hard-tocompress data sets with similar compression/decompression time cost.

  4. Compression experiments on the TOSKA tokamak

    International Nuclear Information System (INIS)

    Cima, G.; McGuire, K.M.; Robinson, D.C.; Wootton, A.J.

    1980-10-01

    Results from minor radius compression experiments on a tokamak plasma in TOSCA are reported. The compression is achieved by increasing the toroidal field up to twice its initial value in 200μs. Measurements show that particles and magnetic flux are conserved. When the initial energy confinement time is comparable with the compression time, energy gains are greater than for an adiabatic change of state. The total beta value increases. Central beta values approximately 3% are measured when a small major radius compression is superimposed on a minor radius compression. Magnetic field fluctuations are affected: both the amplitude and period decrease. Starting from low energy confinement times, approximately 200μs, increases in confinement times up to approximately 1 ms are measured. The increase in plasma energy results from a large reduction in the power losses during the compression. When the initial energy confinement time is much longer than the compression time, the parameter changes are those expected for an adiabatic change of state. (author)

  5. Flux compression generators as plasma compression power sources

    International Nuclear Information System (INIS)

    Fowler, C.M.; Caird, R.S.; Erickson, D.J.; Freeman, B.L.; Thomson, D.B.; Garn, W.B.

    1979-01-01

    A survey is made of applications where explosive-driven magnetic flux compression generators have been or can be used to directly power devices that produce dense plasmas. Representative examples are discussed that are specific to the theta pinch, the plasma gun, the dense plasma focus and the Z pinch. These examples are used to illustrate the high energy and power capabilities of explosive generators. An application employing a rocket-borne, generator-powered plasma gun emphasizes the size and weight potential of flux compression power supplies. Recent results from a local effort to drive a dense plasma focus are provided. Imploding liners ae discussed in the context of both the theta and Z pinches

  6. Studies on diametral compressive strength

    International Nuclear Information System (INIS)

    Awaji, Hideo; Sato, Sennosuke.

    1978-01-01

    A new approach to the diametral compressive tests using circular anvils is proposed on the basis of the analytical study given in the preceding paper. In this approach, the collapse at the contact edges can be avoided. The experimental results obtained by this method for several kinds of graphite and Italian Ondagata light marble are compared with those of the uniaxial tensile strength, and the discrepancy is discussed for a wide range of brittle materials. (auth.)

  7. Properties of compressible elastica from relativistic analogy.

    Science.gov (United States)

    Oshri, Oz; Diamant, Haim

    2016-01-21

    Kirchhoff's kinetic analogy relates the deformation of an incompressible elastic rod to the classical dynamics of rigid body rotation. We extend the analogy to compressible filaments and find that the extension is similar to the introduction of relativistic effects into the dynamical system. The extended analogy reveals a surprising symmetry in the deformations of compressible elastica. In addition, we use known results for the buckling of compressible elastica to derive the explicit solution for the motion of a relativistic nonlinear pendulum. We discuss cases where the extended Kirchhoff analogy may be useful for the study of other soft matter systems.

  8. Compressive Load Resistance Characteristics of Rice Grain

    OpenAIRE

    Sumpun Chaitep; Chaiy R. Metha Pathawee; Pipatpong Watanawanyoo

    2008-01-01

    Investigation was made to observe the compressive load property of rice gain both rough rice and brown grain. Six rice varieties (indica and japonica) were examined with the moisture content at 10-12%. A compressive load with reference to a principal axis normal to the thickness of the grain were conducted at selected inclined angles of 0°, 15°, 30°, 45°, 60° and 70°. The result showed the compressive load resistance of rice grain based on its characteristic of yield s...

  9. Multishock Compression Properties of Warm Dense Argon

    Science.gov (United States)

    Zheng, Jun; Chen, Qifeng; Yunjun, Gu; Li, Zhiguo; Shen, Zhijun

    2015-10-01

    Warm dense argon was generated by a shock reverberation technique. The diagnostics of warm dense argon were performed by a multichannel optical pyrometer and a velocity interferometer system. The equations of state in the pressure-density range of 20-150 GPa and 1.9-5.3 g/cm3 from the first- to fourth-shock compression were presented. The single-shock temperatures in the range of 17.2-23.4 kK were obtained from the spectral radiance. Experimental results indicates that multiple shock-compression ratio (ηi = ρi/ρ0) is greatly enhanced from 3.3 to 8.8, where ρ0 is the initial density of argon and ρi (i = 1, 2, 3, 4) is the compressed density from first to fourth shock, respectively. For the relative compression ratio (ηi’ = ρi/ρi-1), an interesting finding is that a turning point occurs at the second shocked states under the conditions of different experiments, and ηi’ increases with pressure in lower density regime and reversely decreases with pressure in higher density regime. The evolution of the compression ratio is controlled by the excitation of internal degrees of freedom, which increase the compression, and by the interaction effects between particles that reduce it. A temperature-density plot shows that current multishock compression states of argon have distributed into warm dense regime.

  10. Research on compressive sensing reconstruction algorithm based on total variation model

    Science.gov (United States)

    Gao, Yu-xuan; Sun, Huayan; Zhang, Tinghua; Du, Lin

    2017-12-01

    Compressed sensing for breakthrough Nyquist sampling theorem provides a strong theoretical , making compressive sampling for image signals be carried out simultaneously. In traditional imaging procedures using compressed sensing theory, not only can it reduces the storage space, but also can reduce the demand for detector resolution greatly. Using the sparsity of image signal, by solving the mathematical model of inverse reconfiguration, realize the super-resolution imaging. Reconstruction algorithm is the most critical part of compression perception, to a large extent determine the accuracy of the reconstruction of the image.The reconstruction algorithm based on the total variation (TV) model is more suitable for the compression reconstruction of the two-dimensional image, and the better edge information can be obtained. In order to verify the performance of the algorithm, Simulation Analysis the reconstruction result in different coding mode of the reconstruction algorithm based on the TV reconstruction algorithm. The reconstruction effect of the reconfigurable algorithm based on TV based on the different coding methods is analyzed to verify the stability of the algorithm. This paper compares and analyzes the typical reconstruction algorithm in the same coding mode. On the basis of the minimum total variation algorithm, the Augmented Lagrangian function term is added and the optimal value is solved by the alternating direction method.Experimental results show that the reconstruction algorithm is compared with the traditional classical algorithm based on TV has great advantages, under the low measurement rate can be quickly and accurately recovers target image.

  11. ADVANCED RECIPROCATING COMPRESSION TECHNOLOGY (ARCT)

    Energy Technology Data Exchange (ETDEWEB)

    Danny M. Deffenbaugh; Klaus Brun; Ralph E. Harris; J. Pete Harrell; Robert J. Mckee; J. Jeffrey Moore; Steven J. Svedeman; Anthony J. Smalley; Eugene L. Broerman; Robert A Hart; Marybeth G. Nored; Ryan S. Gernentz; Shane P. Siebenaler

    2005-12-01

    The U.S. natural gas pipeline industry is facing the twin challenges of increased flexibility and capacity expansion. To meet these challenges, the industry requires improved choices in gas compression to address new construction and enhancement of the currently installed infrastructure. The current fleet of installed reciprocating compression is primarily slow-speed integral machines. Most new reciprocating compression is and will be large, high-speed separable units. The major challenges with the fleet of slow-speed integral machines are: limited flexibility and a large range in performance. In an attempt to increase flexibility, many operators are choosing to single-act cylinders, which are causing reduced reliability and integrity. While the best performing units in the fleet exhibit thermal efficiencies between 90% and 92%, the low performers are running down to 50% with the mean at about 80%. The major cause for this large disparity is due to installation losses in the pulsation control system. In the better performers, the losses are about evenly split between installation losses and valve losses. The major challenges for high-speed machines are: cylinder nozzle pulsations, mechanical vibrations due to cylinder stretch, short valve life, and low thermal performance. To shift nozzle pulsation to higher orders, nozzles are shortened, and to dampen the amplitudes, orifices are added. The shortened nozzles result in mechanical coupling with the cylinder, thereby, causing increased vibration due to the cylinder stretch mode. Valve life is even shorter than for slow speeds and can be on the order of a few months. The thermal efficiency is 10% to 15% lower than slow-speed equipment with the best performance in the 75% to 80% range. The goal of this advanced reciprocating compression program is to develop the technology for both high speed and low speed compression that will expand unit flexibility, increase thermal efficiency, and increase reliability and integrity

  12. Instability of ties in compression

    DEFF Research Database (Denmark)

    Buch-Hansen, Thomas Cornelius

    2013-01-01

    exact instability solutions are complex to derive, not to mention the extra complexity introducing dimensional instability from the temperature gradients. Using an inverse variable substitution and comparing an exact theory with an analytical instability solution a method to design tie...... the temperature gradient between the outer and the inner wall, which results in critical increase of the bending moments in the ties. Since the ties are loaded by combined compression and moment forces, the loadbearing capacity is derived from instability equilibrium equations. Most of them are iterative, since......-connectors in cavity walls was developed. The method takes into account constraint conditions limiting the free length of the wall tie, and the instability in case of pure compression which gives an optimal load bearing capacity. The model is illustrated with examples from praxis....

  13. Compressed and Practical Data Structures for Strings

    DEFF Research Database (Denmark)

    Christiansen, Anders Roy

    in the following. Finger Search in Grammar-Compressed Strings. Grammar-based compression, where one replaces a long string by a small context-free grammar that generates the string, is a simple and powerful paradigm that captures many popular compression schemes. Given a grammar, the random access problem...... string. We present new data structures that achieve optimal time for updates and queries while using space linear in the size of the optimal relative compression, for nearly all combinations of parameters. We also present solutions for restricted and extended sets of updates. To achieve these results, we...... revisit the dynamic partial sums problem and the substring concatenation problem. We present new optimal or near optimal bounds for these problems. Plugging in our new results we also immediately obtain new bounds for the string indexing for patterns with wildcards problem and the dynamic text and static...

  14. <strong>Neuroeconomics and behavioral health economicsstrong>/>

    DEFF Research Database (Denmark)

    Larsen, Torben

    2009-01-01

    dissemination of relaxation procedures is evident in industrialized countries since about 1970 both inside the medical healthcare system and as NGO-settings in a market-alike competition. However, a serious barrier to the dissemination of meditative de-stressing is the lack of general knowledge of the action...... for explanation of the neural dynamics of normal decision making. Secondly, the literature is reviewed for evidence on hypothesized applications of NeM in behavioral health. Results I. The present bias as documented by neuroeconomic game-trials is explained by NeM as rooted in the basal activation of Amygdala...... - a key center in our emotional arousal (limbic system) - as shaped in the elder stone-age with many acute threats. II. In general, the Hawthorne-effect of human-relations management is explained as the result of supportive job-relations relaxing Amygdala for better emotional integration...

  15. Channel box compression device

    International Nuclear Information System (INIS)

    Nakamizo, Hiroshi; Tanaka, Yuki.

    1996-01-01

    The device of the present invention reduces the volume of spent fuel channel boxes of power plant facilities to eliminate secondary wastes, suppress generation of radiation sources and improve storage space efficiency. The device has a box-like shape. A support frame is disposed on the lateral side of the box for supporting spent channel boxes. A horizontal transferring unit and a vertical transferring compression unit driven by a driving mechanism are disposed in the support frame. Further, the compression unit may have a rotational compression roller so as to move freely in the transferring unit. In addition, the transferring unit and the driving mechanism may be disposed outside of pool water. With such a constitution, since spent channel boxes are compressed and bent by horizontal movement of the transferring unit and the vertical movement of the compression unit, no cut pieces or cut powders are generated. Further, if the transferring unit and the driving mechanism are disposed outside of the pool water, it is not necessary to make them waterproof, which facilitates the maintenance. (I.S.)

  16. Compressed sensing for STEM tomography.

    Science.gov (United States)

    Donati, Laurène; Nilchian, Masih; Trépout, Sylvain; Messaoudi, Cédric; Marco, Sergio; Unser, Michael

    2017-08-01

    A central challenge in scanning transmission electron microscopy (STEM) is to reduce the electron radiation dosage required for accurate imaging of 3D biological nano-structures. Methods that permit tomographic reconstruction from a reduced number of STEM acquisitions without introducing significant degradation in the final volume are thus of particular importance. In random-beam STEM (RB-STEM), the projection measurements are acquired by randomly scanning a subset of pixels at every tilt view. In this work, we present a tailored RB-STEM acquisition-reconstruction framework that fully exploits the compressed sensing principles. We first demonstrate that RB-STEM acquisition fulfills the "incoherence" condition when the image is expressed in terms of wavelets. We then propose a regularized tomographic reconstruction framework to recover volumes from RB-STEM measurements. We demonstrate through simulations on synthetic and real projection measurements that the proposed framework reconstructs high-quality volumes from strongly downsampled RB-STEM data and outperforms existing techniques at doing so. This application of compressed sensing principles to STEM paves the way for a practical implementation of RB-STEM and opens new perspectives for high-quality reconstructions in STEM tomography. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. <strong>Neuroeconomics and Health Economicsstrong>/>

    DEFF Research Database (Denmark)

    Larsen, Torben

    2009-01-01

    activation of Amygdala - a key center in our emotional arousal (limbic system) - as shaped in the elder stone-age with many acute threats. II. In general, the Hawthorne-effect of management is explained as the result of supportive job-relations reinforcing the homeostatic properties of the limbic system...... with de-stressing benefits as reduced anxiety, less use of stimulants and a reduction of blood pressure which in all increase life-expectancy. Conclusion: Neuroeconomics helps economists to identify dominant health economic interventions that may be overlooked by traditional discipålines   [i] This part...

  18. Impact of Compression on the Video Quality

    Directory of Open Access Journals (Sweden)

    Miroslav Uhrina

    2012-01-01

    Full Text Available This article deals with the impact of compression on the video quality. In the first part, a short characteristic of the most used MPEG compression standards is written. In the second part, the parameter Group of Picture (GOP with particular I, P, B frames is explained. The third part focuses on the objective metrics which were used for evaluating the video quality. In the fourth part, the measurements and the experimental results are described.

  19. Prechamber Compression-Ignition Engine Performance

    Science.gov (United States)

    Moore, Charles S; Collins, John H , Jr

    1938-01-01

    Single-cylinder compression-ignition engine tests were made to investigate the performance characteristics of prechamber type of cylinder head. Certain fundamental variables influencing engine performance -- clearance distribution, size, shape, and direction of the passage connecting the cylinder and prechamber, shape of prechamber, cylinder clearance, compression ratio, and boosting -- were independently tested. Results of motoring and of power tests, including several typical indicator cards, are presented.

  20. High-quality compressive ghost imaging

    Science.gov (United States)

    Huang, Heyan; Zhou, Cheng; Tian, Tian; Liu, Dongqi; Song, Lijun

    2018-04-01

    We propose a high-quality compressive ghost imaging method based on projected Landweber regularization and guided filter, which effectively reduce the undersampling noise and improve the resolution. In our scheme, the original object is reconstructed by decomposing of regularization and denoising steps instead of solving a minimization problem in compressive reconstruction process. The simulation and experimental results show that our method can obtain high ghost imaging quality in terms of PSNR and visual observation.

  1. Dynamical Functional Theory for Compressed Sensing

    DEFF Research Database (Denmark)

    Cakmak, Burak; Opper, Manfred; Winther, Ole

    2017-01-01

    We introduce a theoretical approach for designing generalizations of the approximate message passing (AMP) algorithm for compressed sensing which are valid for large observation matrices that are drawn from an invariant random matrix ensemble. By design, the fixed points of the algorithm obey...... that the resulting fields become Gaussian random variables allowing for an explicit analysis. The asymptotic statistics of these fields are consistent with the replica ansatz of the compressed sensing problem....

  2. Celiac artery compression syndrome.

    Science.gov (United States)

    Kokotsakis, J N; Lambidis, C D; Lioulias, A G; Skouteli, E T; Bastounis, E A; Livesay, J J

    2000-04-01

    Celiac artery compression syndrome occurs when the median arcuate ligament of the diaphragm causes extrinsic compression of the celiac trunk. We report a case of a 65-year-old woman who presented with a three-month history of postprandial abdominal pain, nausea and some emesis, without weight loss. There was a bruit in the upper mid-epigastrium and the lateral aortic arteriography revealed a significant stenosis of the celiac artery. At operation, the celiac axis was found to be severely compressed anteriorly by fibers forming the inferior margin of the arcuate ligament of the diaphragm. The ligament was cut and a vein by-pass from the supraceliac aorta to the distal celiac artery was performed. The patient remains well and free of symptoms two and a half years since operation.In this report we discuss the indications and the therapeutic options of this syndrome as well as a review of the literature is being given.

  3. Isentropic Compression of Argon

    International Nuclear Information System (INIS)

    Oona, H.; Solem, J.C.; Veeser, L.R.; Ekdahl, C.A.; Rodriquez, P.J.; Younger, S.M.; Lewis, W.; Turley, W.D.

    1997-01-01

    We are studying the transition of argon from an insulator to a conductor by compressing the frozen gas isentropically to pressures at which neighboring atomic orbitals overlap sufficiently to allow some electron motion between atoms. Argon and the other rare gases have closed electron shells and therefore remain montomic, even when they solidify. Their simple structure makes it likely that any measured change in conductivity is due to changes in the atomic structure, not in molecular configuration. As the crystal is compressed the band gap closes, allowing increased conductivity. We have begun research to determine the conductivity at high pressures, and it is our intention to determine the compression at which the crystal becomes a metal

  4. <strong>Neuroeconomics and behavioral health economicsstrong>/>

    DEFF Research Database (Denmark)

    Larsen, Torben

    2009-01-01

    - a key center in our emotional arousal (limbic system) - as shaped in the elder stone-age with many acute threats. II. In general, the Hawthorne-effect of human-relations management is explained as the result of supportive job-relations relaxing Amygdala for better emotional integration...... some are rooted in the religious tradition while other aim to be post-religious. Medical meditation across settings combines savings on health care costs with de-stressing benefits as reduced anxiety, less use of stimulants and a reduction of blood pressure which in all increase life...... is met by a meso-strategy aiming the formation of an international, multidisciplinary network which might organize regional workshops for representatives for all involved parties in order to prepare local implementation projects.   Regarding de-stressing by medical meditation a relatively fast...

  5. Titanium: light, strong, and white

    Science.gov (United States)

    Woodruff, Laurel; Bedinger, George

    2013-01-01

    Titanium (Ti) is a strong silver-gray metal that is highly resistant to corrosion and is chemically inert. It is as strong as steel but 45 percent lighter, and it is twice as strong as aluminum but only 60 percent heavier. Titanium dioxide (TiO2) has a very high refractive index, which means that it has high light-scattering ability. As a result, TiO2 imparts whiteness, opacity, and brightness to many products. ...Because of the unique physical properties of titanium metal and the whiteness provided by TiO2, titanium is now used widely in modern industrial societies.

  6. Effects of Strong CYP3A Inhibition and Induction on the Pharmacokinetics of Ixazomib, an Oral Proteasome Inhibitor: Results of Drug-Drug Interaction Studies in Patients With Advanced Solid Tumors or Lymphoma and a Physiologically Based Pharmacokinetic Analysis.

    Science.gov (United States)

    Gupta, Neeraj; Hanley, Michael J; Venkatakrishnan, Karthik; Bessudo, Alberto; Rasco, Drew W; Sharma, Sunil; O'Neil, Bert H; Wang, Bingxia; Liu, Guohui; Ke, Alice; Patel, Chirag; Rowland Yeo, Karen; Xia, Cindy; Zhang, Xiaoquan; Esseltine, Dixie-Lee; Nemunaitis, John

    2018-02-01

    At clinically relevant ixazomib concentrations, in vitro studies demonstrated that no specific cytochrome P450 (CYP) enzyme predominantly contributes to ixazomib metabolism. However, at higher than clinical concentrations, ixazomib was metabolized by multiple CYP isoforms, with the estimated relative contribution being highest for CYP3A at 42%. This multiarm phase 1 study (Clinicaltrials.gov identifier: NCT01454076) investigated the effect of the strong CYP3A inhibitors ketoconazole and clarithromycin and the strong CYP3A inducer rifampin on the pharmacokinetics of ixazomib. Eighty-eight patients were enrolled across the 3 drug-drug interaction studies; the ixazomib toxicity profile was consistent with previous studies. Ketoconazole and clarithromycin had no clinically meaningful effects on the pharmacokinetics of ixazomib. The geometric least-squares mean area under the plasma concentration-time curve from 0 to 264 hours postdose ratio (90%CI) with vs without ketoconazole coadministration was 1.09 (0.91-1.31) and was 1.11 (0.86-1.43) with vs without clarithromycin coadministration. Reduced plasma exposures of ixazomib were observed following coadministration with rifampin. Ixazomib area under the plasma concentration-time curve from time 0 to the time of the last quantifiable concentration was reduced by 74% (geometric least-squares mean ratio of 0.26 [90%CI 0.18-0.37]), and maximum observed plasma concentration was reduced by 54% (geometric least-squares mean ratio of 0.46 [90%CI 0.29-0.73]) in the presence of rifampin. The clinical drug-drug interaction study results were reconciled well by a physiologically based pharmacokinetic model that incorporated a minor contribution of CYP3A to overall ixazomib clearance and quantitatively considered the strength of induction of CYP3A and intestinal P-glycoprotein by rifampin. On the basis of these study results, the ixazomib prescribing information recommends that patients should avoid concomitant administration of

  7. Issues in multiview autostereoscopic image compression

    Science.gov (United States)

    Shah, Druti; Dodgson, Neil A.

    2001-06-01

    Multi-view auto-stereoscopic images and image sequences require large amounts of space for storage and large bandwidth for transmission. High bandwidth can be tolerated for certain applications where the image source and display are close together but, for long distance or broadcast, compression of information is essential. We report on the results of our two- year investigation into multi-view image compression. We present results based on four techniques: differential pulse code modulation (DPCM), disparity estimation, three- dimensional discrete cosine transform (3D-DCT), and principal component analysis (PCA). Our work on DPCM investigated the best predictors to use for predicting a given pixel. Our results show that, for a given pixel, it is generally the nearby pixels within a view that provide better prediction than the corresponding pixel values in adjacent views. This led to investigations into disparity estimation. We use both correlation and least-square error measures to estimate disparity. Both perform equally well. Combining this with DPCM led to a novel method of encoding, which improved the compression ratios by a significant factor. The 3D-DCT has been shown to be a useful compression tool, with compression schemes based on ideas from the two-dimensional JPEG standard proving effective. An alternative to 3D-DCT is PCA. This has proved to be less effective than the other compression methods investigated.

  8. Double compression: a vision for compressing morbidity and caregiving in dementia.

    Science.gov (United States)

    Cheng, Sheung-Tak

    2014-12-01

    The anticipated rise of dementia prevalence due to global aging may be tackled by morbidity compression through lifestyle changes (i.e., consistent participation in physical and intellectual activities) that promote cognitive reserve. A hypothetical model of cognitive decline due to Alzheimer's disease (AD) and modulation of the clinical trajectory by cognitive reserve is presented. People with higher cognitive reserve are expected to show delay of the mild cognitive impairment phase but faster conversion to AD thereafter. Once conversion to AD is evident, there would be even faster deterioration, resulting in compression of morbidity. When morbidity is compressed, not only is prevalence reduced but the caregiving load is also compressed; this is referred to as "double compression." Research and policy directions are discussed. © The Author 2014. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Anisotropic Concrete Compressive Strength

    DEFF Research Database (Denmark)

    Gustenhoff Hansen, Søren; Jørgensen, Henrik Brøner; Hoang, Linh Cao

    2017-01-01

    When the load carrying capacity of existing concrete structures is (re-)assessed it is often based on compressive strength of cores drilled out from the structure. Existing studies show that the core compressive strength is anisotropic; i.e. it depends on whether the cores are drilled parallel...... correlation to the curing time. The experiments show no correlation between the anisotropy and the curing time and a small strength difference between the two drilling directions. The literature shows variations on which drilling direction that is strongest. Based on a Monto Carlo simulation of the expected...

  10. Image data compression investigation

    Science.gov (United States)

    Myrie, Carlos

    1989-01-01

    NASA continuous communications systems growth has increased the demand for image transmission and storage. Research and analysis was conducted on various lossy and lossless advanced data compression techniques or approaches used to improve the efficiency of transmission and storage of high volume stellite image data such as pulse code modulation (PCM), differential PCM (DPCM), transform coding, hybrid coding, interframe coding, and adaptive technique. In this presentation, the fundamentals of image data compression utilizing two techniques which are pulse code modulation (PCM) and differential PCM (DPCM) are presented along with an application utilizing these two coding techniques.

  11. A Simulation-based Randomized Controlled Study of Factors Influencing Chest Compression Depth

    Directory of Open Access Journals (Sweden)

    Kelsey P. Mayrand

    2015-12-01

    Full Text Available Introduction: Current resuscitation guidelines emphasize a systems approach with a strong emphasis on quality cardiopulmonary resuscitation (CPR. Despite the American Heart Association (AHA emphasis on quality CPR for over 10 years, resuscitation teams do not consistently meet recommended CPR standards. The objective is to assess the impact on chest compression depth of factors including bed height, step stool utilization, position of the rescuer’s arms and shoulders relative to the point of chest compression, and rescuer characteristics including height, weight, and gender. Methods: Fifty-six eligible subjects, including physician assistant students and first-year emergency medicine residents, were enrolled and randomized to intervention (bed lowered and step stool readily available and control (bed raised and step stool accessible, but concealed groups. We instructed all subjects to complete all interventions on a high-fidelity mannequin per AHA guidelines. Secondary end points included subject arm angle, height, weight group, and gender. Results: Using an intention to treat analysis, the mean compression depths for the intervention and control groups were not significantly different. Subjects positioning their arms at a 90-degree angle relative to the sagittal plane of the mannequin’s chest achieved a mean compression depth significantly greater than those compressing at an angle less than 90 degrees. There was a significant correlation between using a step stool and achieving the correct shoulder position. Subject height, weight group, and gender were all independently associated with compression depth. Conclusion: Rescuer arm position relative to the patient’s chest and step stool utilization during CPR are modifiable factors facilitating improved chest compression depth.

  12. Fingerprint Compression Based on Sparse Representation.

    Science.gov (United States)

    Shao, Guangqi; Wu, Yanping; A, Yong; Liu, Xiao; Guo, Tiande

    2014-02-01

    A new fingerprint compression algorithm based on sparse representation is introduced. Obtaining an overcomplete dictionary from a set of fingerprint patches allows us to represent them as a sparse linear combination of dictionary atoms. In the algorithm, we first construct a dictionary for predefined fingerprint image patches. For a new given fingerprint images, represent its patches according to the dictionary by computing l(0)-minimization and then quantize and encode the representation. In this paper, we consider the effect of various factors on compression results. Three groups of fingerprint images are tested. The experiments demonstrate that our algorithm is efficient compared with several competing compression techniques (JPEG, JPEG 2000, and WSQ), especially at high compression ratios. The experiments also illustrate that the proposed algorithm is robust to extract minutiae.

  13. Fast Compression and Decompression capabilities at HPCAT, APS

    Science.gov (United States)

    Sinogeikin, S. V.

    2016-12-01

    Materials behavior and phase transformation pathways are strongly influenced by the time dependence of the driving mechanism (compression, thermal transfer, strain, irradiation, etc). While shock compression and static compression are well established techniques available for a long time, the techniques filling the compression rate gap and studying materials behavior as a function of compression rates at intermediate rates remain scarce. Recent advances in synchrotron sources, x-ray optics, fast area detectors, and sample environment control have enabled many time-resolved experimental techniques for studying materials at extreme pressure and temperature conditions. The High Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source has made a sustained effort to develop and assemble a powerful collection of high-pressure apparatus for time-resolved research and developing techniques for collecting high-quality time-resolved x-ray scattering data at compression rates intermediate between static and shock compression experiments. In this talk we will outline recently developed capabilities at HPCAT for synthesis of metastable and amorphous materials and studying properties (EOS, lattice relaxation, etc.) and phase transition mechanisms of materials using fast unidirectional and cyclic compression-decompression with variable strain rates up to extreme compression of tens of TPa per second.

  14. Strongly Correlated Topological Insulators

    Science.gov (United States)

    2016-02-03

    Strongly Correlated Topological Insulators In the past year, the grant was used for work in the field of topological phases, with emphasis on finding...surface of topological insulators. In the past 3 years, we have started a new direction, that of fractional topological insulators. These are materials...in which a topologically nontrivial quasi-flat band is fractionally filled and then subject to strong interactions. The views, opinions and/or

  15. Shock absorbing properties of toroidal shells under compression, 3

    International Nuclear Information System (INIS)

    Sugita, Yuji

    1985-01-01

    The author has previously presented the static load-deflection relations of a toroidal shell subjected to axisymmetric compression between rigid plates and those of its outer half when subjected to lateral compression. In both these cases, the analytical method was based on the incremental Rayleigh-Ritz method. In this paper, the effects of compression angle and strain rate on the load-deflection relations of the toroidal shell are investigated for its use as a shock absorber for the radioactive material shipping cask which must keep its structural integrity even after accidental falls at any angle. Static compression tests have been carried out at four angles of compression, 10 0 , 20 0 , 50 0 , 90 0 and the applications of the preceding analytical method have been discussed. Dynamic compression tests have also been performed using the free-falling drop hammer. The results are compared with those in the static compression tests. (author)

  16. Temporal compressive sensing systems

    Science.gov (United States)

    Reed, Bryan W.

    2017-12-12

    Methods and systems for temporal compressive sensing are disclosed, where within each of one or more sensor array data acquisition periods, one or more sensor array measurement datasets comprising distinct linear combinations of time slice data are acquired, and where mathematical reconstruction allows for calculation of accurate representations of the individual time slice datasets.

  17. Compressive CFAR Radar Processing

    NARCIS (Netherlands)

    Anitori, L.; Rossum, W.L. van; Otten, M.P.G.; Maleki, A.; Baraniuk, R.

    2013-01-01

    In this paper we investigate the performance of a combined Compressive Sensing (CS) Constant False Alarm Rate (CFAR) radar processor under different interference scenarios using both the Cell Averaging (CA) and Order Statistic (OS) CFAR detectors. Using the properties of the Complex Approximate

  18. Compressive CFAR radar detection

    NARCIS (Netherlands)

    Anitori, L.; Otten, M.P.G.; Rossum, W.L. van; Maleki, A.; Baraniuk, R.

    2012-01-01

    In this paper we develop the first Compressive Sensing (CS) adaptive radar detector. We propose three novel architectures and demonstrate how a classical Constant False Alarm Rate (CFAR) detector can be combined with ℓ1-norm minimization. Using asymptotic arguments and the Complex Approximate

  19. Gas compression infrared generator

    International Nuclear Information System (INIS)

    Hug, W.F.

    1980-01-01

    A molecular gas is compressed in a quasi-adiabatic manner to produce pulsed radiation during each compressor cycle when the pressure and temperature are sufficiently high, and part of the energy is recovered during the expansion phase, as defined in U.S. Pat. No. 3,751,666; characterized by use of a cylinder with a reciprocating piston as a compressor

  20. Multiple snapshot compressive beamforming

    DEFF Research Database (Denmark)

    Gerstoft, Peter; Xenaki, Angeliki; Mecklenbrauker, Christoph F.

    2015-01-01

    For sound fields observed on an array, compressive sensing (CS) reconstructs the multiple source signals at unknown directions-of-arrival (DOAs) using a sparsity constraint. The DOA estimation is posed as an underdetermined problem expressing the field at each sensor as a phase-lagged superposition...

  1. <strong>PRAYER INDUCED ANALGESIAstrong>

    DEFF Research Database (Denmark)

    Jegindø, Else-Marie Elmholdt

    moderators (personality, absorption and coping) and mediators (expectations, desire for pain relief and anxiety) were included in the study design in order to explore the influence of psychological mechanisms involved in the potential analgesic effect of prayer as a coping strategy. RESULTS: TBA (it...

  2. A review of medical image compression methods - general characterization

    Energy Technology Data Exchange (ETDEWEB)

    Przelaskowski, A.; Kazubek, M.; Jamrogiewicz, T. [Politechnika Warszawska, Warsaw (Poland). Inst. Radioelektroniki

    1995-12-31

    The general view of the popular and often applied lossless and lossy compression techniques is presented. The lossless methods of either single image (intraframe methods ) or sequence of correlated images (interframe methods) are shortly characterized. Often used lossy methods are also introduced. A class of medical images has not specific features which could be used for improving the compression efficiency. The effective natural image lossless compression techniques are also efficient in the applications to medical image systems. The limit of achievable compression ratios is about 4. Techniques based on linear prediction methods are largely the most effective in reduction of spatial redundancy. An optimisation of prediction model allows to decrease bit rates of about 10% (over standard DPCM method). there is strong dependence of a conception of compression technique optimum conditions on specific application and realisation possibilities of the technique. (author). 35 refs, 2 fig.

  3. Breast compression in mammography: pressure distribution patterns.

    Science.gov (United States)

    Dustler, Magnus; Andersson, Ingvar; Brorson, Håkan; Fröjd, Patrik; Mattsson, Sören; Tingberg, Anders; Zackrisson, Sophia; Förnvik, Daniel

    2012-11-01

    Breast compression is important in mammography in order to improve image quality, better separate tissue components, and reduce absorbed dose to the breast. In this study we use a method to measure and visualize the distribution of pressure over a compressed breast in mammography. To measure and describe the pressure distribution over the breast as a result of applied breast compression in mammography. One hundred and three women aged 40.7-74.3 years (median, 48.9 years) invited for mammographic screening consented to take part in this study. They were subjected to two additional breast compressions of the left breast (standard force and approximately 50% reduction). Pressure images of the compressed breast were obtained using force sensing resistor (FSR) sensors placed underneath the compression plate. Subjects rated their experience of pain on a visual analogue scale (VAS). Four pressure patterns were identified, fitting 81 of the 103 breasts, which were grouped accordingly. The remaining 22 breasts were found to correspond to a combination of any two patterns. Two groups (43 breasts) showed pressure mainly over the juxtathoracic part of the breast, had significantly greater breast thickness (P = 0.003) and had a lower mean pressure over dense tissue (P force increased average breast thickness by 1.8 mm (P force being absorbed in juxtathoracic structures.

  4. Strong Arcwise Connectedness

    OpenAIRE

    Espinoza, Benjamin; Gartside, Paul; Kovan-Bakan, Merve; Mamatelashvili, Ana

    2012-01-01

    A space is `n-strong arc connected' (n-sac) if for any n points in the space there is an arc in the space visiting them in order. A space is omega-strong arc connected (omega-sac) if it is n-sac for all n. We study these properties in finite graphs, regular continua, and rational continua. There are no 4-sac graphs, but there are 3-sac graphs and graphs which are 2-sac but not 3-sac. For every n there is an n-sac regular continuum, but no regular continuum is omega-sac. There is an omega-sac ...

  5. Abortion: Strong's counterexamples fail

    DEFF Research Database (Denmark)

    Di Nucci, Ezio

    2009-01-01

    This paper shows that the counterexamples proposed by Strong in 2008 in the Journal of Medical Ethics to Marquis's argument against abortion fail. Strong's basic idea is that there are cases--for example, terminally ill patients--where killing an adult human being is prima facie seriously morally......'s scenarios have some valuable future or admitted that killing them is not seriously morally wrong. Finally, if "valuable future" is interpreted as referring to objective standards, one ends up with implausible and unpalatable moral claims....

  6. Fundamental study of compression for movie files of coronary angiography

    Science.gov (United States)

    Ando, Takekazu; Tsuchiya, Yuichiro; Kodera, Yoshie

    2005-04-01

    When network distribution of movie files was considered as reference, it could be useful that the lossy compression movie files which has small file size. We chouse three kinds of coronary stricture movies with different moving speed as an examination object; heart rate of slow, normal and fast movies. The movies of MPEG-1, DivX5.11, WMV9 (Windows Media Video 9), and WMV9-VCM (Windows Media Video 9-Video Compression Manager) were made from three kinds of AVI format movies with different moving speeds. Five kinds of movies that are four kinds of compression movies and non-compression AVI instead of the DICOM format were evaluated by Thurstone's method. The Evaluation factors of movies were determined as "sharpness, granularity, contrast, and comprehensive evaluation." In the virtual bradycardia movie, AVI was the best evaluation at all evaluation factors except the granularity. In the virtual normal movie, an excellent compression technique is different in all evaluation factors. In the virtual tachycardia movie, MPEG-1 was the best evaluation at all evaluation factors expects the contrast. There is a good compression form depending on the speed of movies because of the difference of compression algorithm. It is thought that it is an influence by the difference of the compression between frames. The compression algorithm for movie has the compression between the frames and the intra-frame compression. As the compression algorithm give the different influence to image by each compression method, it is necessary to examine the relation of the compression algorithm and our results.

  7. Watermark Compression in Medical Image Watermarking Using Lempel-Ziv-Welch (LZW) Lossless Compression Technique.

    Science.gov (United States)

    Badshah, Gran; Liew, Siau-Chuin; Zain, Jasni Mohd; Ali, Mushtaq

    2016-04-01

    In teleradiology, image contents may be altered due to noisy communication channels and hacker manipulation. Medical image data is very sensitive and can not tolerate any illegal change. Illegally changed image-based analysis could result in wrong medical decision. Digital watermarking technique can be used to authenticate images and detect as well as recover illegal changes made to teleradiology images. Watermarking of medical images with heavy payload watermarks causes image perceptual degradation. The image perceptual degradation directly affects medical diagnosis. To maintain the image perceptual and diagnostic qualities standard during watermarking, the watermark should be lossless compressed. This paper focuses on watermarking of ultrasound medical images with Lempel-Ziv-Welch (LZW) lossless-compressed watermarks. The watermark lossless compression reduces watermark payload without data loss. In this research work, watermark is the combination of defined region of interest (ROI) and image watermarking secret key. The performance of the LZW compression technique was compared with other conventional compression methods based on compression ratio. LZW was found better and used for watermark lossless compression in ultrasound medical images watermarking. Tabulated results show the watermark bits reduction, image watermarking with effective tamper detection and lossless recovery.

  8. Compressive Strength of Bottle-Shaped Compression Fields of Fiber Reinforced Concrete Members

    Directory of Open Access Journals (Sweden)

    Hussein Al-Quraishi

    2011-11-01

    Full Text Available Applying load to a structural member may result in a bottle-shaped compression field especially when the width of the loading is less than the width of bearing concrete members. At the Building and Construction Department – the University of Technology-Iraq, series tests on fibre reinforced concrete specimens were carried out, subjected to compression forces at the top and bottom of the specimens to produce compression field. The effects of steel fibre content, concrete compressive strength, transverse tension reinforcement, the height of test specimen, and the ratio of the width of loading plate to specimen width were studied by testing a total of tenth normal strength concrete blocks with steel fibre and one normal strength concrete block without steel fibres. Based on experimental results; all the test specimens failed with the splitting of concrete directly under the loading plate. Increased the uniaxial compressive strength of concrete increases the maximum bearing capacity of compressive stresses. The load-transverse deformation initially behaves linearly and shows some nonlinearity before failure. Addition of steel fibre to normal strength concrete or presence of transverse reinforcement, delay the reaching of maximum compressive stress after the presence of the first crack.

  9. Tree compression with top trees

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Landau, Gad M.

    2013-01-01

    We introduce a new compression scheme for labeled trees based on top trees [3]. Our compression scheme is the first to simultaneously take advantage of internal repeats in the tree (as opposed to the classical DAG compression that only exploits rooted subtree repeats) while also supporting fast...

  10. Tree compression with top trees

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Landau, Gad M.

    2015-01-01

    We introduce a new compression scheme for labeled trees based on top trees. Our compression scheme is the first to simultaneously take advantage of internal repeats in the tree (as opposed to the classical DAG compression that only exploits rooted subtree repeats) while also supporting fast...

  11. Exploiting chaos-based compressed sensing and cryptographic algorithm for image encryption and compression

    Science.gov (United States)

    Chen, Junxin; Zhang, Yu; Qi, Lin; Fu, Chong; Xu, Lisheng

    2018-02-01

    This paper presents a solution for simultaneous image encryption and compression. The primary introduced techniques are compressed sensing (CS) using structurally random matrix (SRM), and permutation-diffusion type image encryption. The encryption performance originates from both the techniques, whereas the compression effect is achieved by CS. Three-dimensional (3-D) cat map is employed for key stream generation. The simultaneously produced three state variables of 3-D cat map are respectively used for the SRM generation, image permutation and diffusion. Numerical simulations and security analyses have been carried out, and the results demonstrate the effectiveness and security performance of the proposed system.

  12. Limits to compression with cascaded quadratic soliton compressors

    DEFF Research Database (Denmark)

    Bache, Morten; Bang, Ole; Krolikowski, Wieslaw

    2008-01-01

    We study cascaded quadratic soliton compressors and address the physical mechanisms that limit the compression. A nonlocal model is derived, and the nonlocal response is shown to have an additional oscillatory component in the nonstationary regime when the group-velocity mismatch (GVM) is strong....... This inhibits efficient compression. Raman-like perturbations from the cascaded nonlinearity, competing cubic nonlinearities, higher-order dispersion, and soliton energy may also limit compression, and through realistic numerical simulations we point out when each factor becomes important. We find...

  13. Fingerprints in compressed strings

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Cording, Patrick Hagge

    2017-01-01

    In this paper we show how to construct a data structure for a string S of size N compressed into a context-free grammar of size n that supports efficient Karp–Rabin fingerprint queries to any substring of S. That is, given indices i and j, the answer to a query is the fingerprint of the substring S......[i,j]. We present the first O(n) space data structures that answer fingerprint queries without decompressing any characters. For Straight Line Programs (SLP) we get O(log⁡N) query time, and for Linear SLPs (an SLP derivative that captures LZ78 compression and its variations) we get O(log⁡log⁡N) query time...

  14. Compressive CFAR Radar Processing

    OpenAIRE

    Anitori, Laura; Baraniuk, Richard; Maleki, Arian; Otten, Matern; van Rossum, Wim

    2013-01-01

    In this paper we investigate the performance of a combined Compressive Sensing (CS) Constant False Alarm Rate (CFAR) radar processor under different interference scenarios using both the Cell Averaging (CA) and Order Statistic (OS) CFAR detectors. Using the properties of the Complex Approximate Message Passing (CAMP) algorithm, we demonstrate that the behavior of the CFAR processor is independent of the combination with the non-linear recovery and therefore its performance can be predicted us...

  15. Recursive Compressed Sensing

    OpenAIRE

    Freris, Nikolaos M.; Öçal, Orhan; Vetterli, Martin

    2013-01-01

    We introduce a recursive algorithm for performing compressed sensing on streaming data. The approach consists of a) recursive encoding, where we sample the input stream via overlapping windowing and make use of the previous measurement in obtaining the next one, and b) recursive decoding, where the signal estimate from the previous window is utilized in order to achieve faster convergence in an iterative optimization scheme applied to decode the new one. To remove estimation bias, a two-step ...

  16. Universal Compressed Sensing

    OpenAIRE

    Jalali, Shirin; Poor, H. Vincent

    2014-01-01

    In this paper, the problem of developing universal algorithms for compressed sensing of stochastic processes is studied. First, R\\'enyi's notion of information dimension (ID) is generalized to analog stationary processes. This provides a measure of complexity for such processes and is connected to the number of measurements required for their accurate recovery. Then a minimum entropy pursuit (MEP) optimization approach is proposed, and it is proven that it can reliably recover any stationary ...

  17. Kalman Filtered Compressed Sensing

    OpenAIRE

    Vaswani, Namrata

    2008-01-01

    We consider the problem of reconstructing time sequences of spatially sparse signals (with unknown and time-varying sparsity patterns) from a limited number of linear "incoherent" measurements, in real-time. The signals are sparse in some transform domain referred to as the sparsity basis. For a single spatial signal, the solution is provided by Compressed Sensing (CS). The question that we address is, for a sequence of sparse signals, can we do better than CS, if (a) the sparsity pattern of ...

  18. Compressibility study of quaternary phospholipid blend monolayers.

    Science.gov (United States)

    Cavalcanti, Leide P; Tho, Ingunn; Konovalov, Oleg; Fossheim, Sigrid; Brandl, Martin

    2011-07-01

    The mechanical properties of liposome membranes are strongly dependent on type and ratio of lipid compounds, which can have important role in drug targeting and release processes when liposome is used as drug carrier. In this work we have used Brewster's angle microscopy to monitor the lateral compression process of lipid monolayers containing as helper lipids either distearoyl phosphatidylethanolamine (DSPE) or dioleoyl phophatidylethanolamine (DOPE) molecules on the Langmuir trough. The compressibility coefficient was determined for lipid blend monolayers containing the helper lipids above, cholesterol, distearoyl phosphatidylcholine (DSPC) and pegylated-DSPE at room temperature. Two variables, the cholesterol fraction and the ratio ρ between the helper lipid (either DSPE or DOPE) and the reference lipid DSPC, were studied by multivariate analysis to evaluate their impact on the compressibility coefficient of the monolayers. The cholesterol level was found to be the most significant variable for DSPE blends while the ratio ρ was the most significant one for DOPE blend monolayers. It was also found that these two variables can exhibit positive interaction and the same compressibility value can be obtained with different blend compositions. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Strong Electroweak Symmetry Breaking

    CERN Document Server

    Grinstein, Benjamin

    2011-01-01

    Models of spontaneous breaking of electroweak symmetry by a strong interaction do not have fine tuning/hierarchy problem. They are conceptually elegant and use the only mechanism of spontaneous breaking of a gauge symmetry that is known to occur in nature. The simplest model, minimal technicolor with extended technicolor interactions, is appealing because one can calculate by scaling up from QCD. But it is ruled out on many counts: inappropriately low quark and lepton masses (or excessive FCNC), bad electroweak data fits, light scalar and vector states, etc. However, nature may not choose the minimal model and then we are stuck: except possibly through lattice simulations, we are unable to compute and test the models. In the LHC era it therefore makes sense to abandon specific models (of strong EW breaking) and concentrate on generic features that may indicate discovery. The Technicolor Straw Man is not a model but a parametrized search strategy inspired by a remarkable generic feature of walking technicolor,...

  20. An Adaptive Lossless Data Compression Scheme for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Jonathan Gana Kolo

    2012-01-01

    Full Text Available Energy is an important consideration in the design and deployment of wireless sensor networks (WSNs since sensor nodes are typically powered by batteries with limited capacity. Since the communication unit on a wireless sensor node is the major power consumer, data compression is one of possible techniques that can help reduce the amount of data exchanged between wireless sensor nodes resulting in power saving. However, wireless sensor networks possess significant limitations in communication, processing, storage, bandwidth, and power. Thus, any data compression scheme proposed for WSNs must be lightweight. In this paper, we present an adaptive lossless data compression (ALDC algorithm for wireless sensor networks. Our proposed ALDC scheme performs compression losslessly using multiple code options. Adaptive compression schemes allow compression to dynamically adjust to a changing source. The data sequence to be compressed is partitioned into blocks, and the optimal compression scheme is applied for each block. Using various real-world sensor datasets we demonstrate the merits of our proposed compression algorithm in comparison with other recently proposed lossless compression algorithms for WSNs.

  1. Football Equipment Removal Improves Chest Compression and Ventilation Efficacy.

    Science.gov (United States)

    Mihalik, Jason P; Lynall, Robert C; Fraser, Melissa A; Decoster, Laura C; De Maio, Valerie J; Patel, Amar P; Swartz, Erik E

    2016-01-01

    Airway access recommendations in potential catastrophic spine injury scenarios advocate for facemask removal, while keeping the helmet and shoulder pads in place for ensuing emergency transport. The anecdotal evidence to support these recommendations assumes that maintaining the helmet and shoulder pads assists inline cervical stabilization and that facial access guarantees adequate airway access. Our objective was to determine the effect of football equipment interference on performing chest compressions and delivering adequate ventilations on patient simulators. We hypothesized that conditions with more football equipment would decrease chest compression and ventilation efficacy. Thirty-two certified athletic trainers were block randomized to participate in six different compression conditions and six different ventilation conditions using human patient simulators. Data for chest compression (mean compression depth, compression rate, percentage of correctly released compressions, and percentage of adequate compressions) and ventilation (total ventilations, mean ventilation volume, and percentage of ventilations delivering adequate volume) conditions were analyzed across all conditions. The fully equipped athlete resulted in the lowest mean compression depth (F5,154 = 22.82; P football athletes who require cardiopulmonary resuscitation, while maintaining appropriate cervical spine stabilization when injury is suspected. Further research is needed to confirm our findings supporting full equipment removal for chest compression and ventilation delivery.

  2. A new display stream compression standard under development in VESA

    Science.gov (United States)

    Jacobson, Natan; Thirumalai, Vijayaraghavan; Joshi, Rajan; Goel, James

    2017-09-01

    The Advanced Display Stream Compression (ADSC) codec project is in development in response to a call for technologies from the Video Electronics Standards Association (VESA). This codec targets visually lossless compression of display streams at a high compression rate (typically 6 bits/pixel) for mobile/VR/HDR applications. Functionality of the ADSC codec is described in this paper, and subjective trials results are provided using the ISO 29170-2 testing protocol.

  3. Lossless Compression of Stereo Disparity Maps for 3D

    DEFF Research Database (Denmark)

    Zamarin, Marco; Forchhammer, Søren

    2012-01-01

    . The coding algorithm is based on bit-plane coding, disparity prediction via disparity warping and context-based arithmetic coding exploiting predicted disparity data. Experimental results show that the proposed compression scheme achieves average compression factors of about 48:1 for high resolution...... disparity maps for stereo pairs and outperforms different standard solutions for lossless still image compression. Moreover, it provides a progressive representation of disparity data as well as a parallelizable structure....

  4. Total Correlation Function Integrals and Isothermal Compressibilities from Molecular Simulations

    DEFF Research Database (Denmark)

    Wedberg, Rasmus; Peters, Günther H.j.; Abildskov, Jens

    2008-01-01

    Generation of thermodynamic data, here compressed liquid density and isothermal compressibility data, using molecular dynamics simulations is investigated. Five normal alkane systems are simulated at three different state points. We compare two main approaches to isothermal compressibilities: (1......) fluctuation solution theory analysis of trajectories obtained from simulations to yield total correlation function integrals; and (2) the more commonly used fluctuation formula. The results show that the two approaches yield consistent values and consistent uncertainties. Also, the computations converge...

  5. Compressive properties of aluminum foams by gas injection method

    OpenAIRE

    Zhang Huiming; Chen Xiang; Fan Xueliu

    2012-01-01

    The compressive properties of aluminum foams by gas injection method are investigated under both quasi-static and dynamic compressive loads in this paper. The experimental results indicate that the deformation of the aluminum foams goes through three stages: elastic deforming, plastic deforming and densification stage, during both the quasi-static and dynamic compressions. The aluminum foams with small average cell size or low porosity have high yield strength. An increase in strain rate can ...

  6. Compressible turbulence in one dimension

    Science.gov (United States)

    Fleischer, Jason Wolf

    1999-11-01

    The Burgers' model of compressible fluid dynamics in one dimension is extended to include the effects of pressure back-reaction. The new system consists of two coupled equations: Burgers' equation with a pressure gradient (essentially the 1-D Navier-Stokes equation) and an advection-diffusion equation for the pressure field. It presents a minimal model of both adiabatic gas dynamics and compressible magnetohydrodynamics. From the magnetic perspective, it is the simplest possible system which allows for Alfvenization, i.e. energy transfer between the fluid and the magnetic field. For the special case of equal fluid viscosity and (magnetic) diffusivity, the system is completely integrable, reducing to two decoupled Burgers' equations in the characteristic variables v +/- vsound ( v +/- vAlfven). For arbitrary diffusivities, renormalized perturbation theory is used to calculate the effective transport coefficients for forced Burgerlence. It is shown that energy equi- dissipation, not equipartition, is fundamental to the turbulent state. Both energy and dissipation are localized to shock-like structures, in which wave steepening is inhibited by small-scale forcing and by pressure back-reaction. The spectral forms predicted by theory are confirmed by numerical simulations. It is shown that the velocity structures lead to an asymmetric velocity PDF, as in Burgers' turbulence. Pressure fluctuations, however, are symmetrically distributed. A Fokker-Planck calculation of these distributions is compared and contrasted with a path integral approach. The latter instanton solution suggests that the system maintains its characteristic directions in steady-state turbulence, supporting the results from perturbation theory. Implications for the spectra of turbulence and self-organization phenomena in compressible fluids and plasmas are also discussed.

  7. Masker phase effects in normal-hearing and hearing-impaired listeners: evidence for peripheral compression at low signal frequencies

    DEFF Research Database (Denmark)

    Oxenham, Andrew J.; Dau, Torsten

    2004-01-01

    curvature. Results from 12 listeners with sensorineural hearing loss showed reduced masker phase effects, when compared with data from normal-hearing listeners, at both 250- and 1000-Hz signal frequencies. The effects of hearing impairment on phase-related masking differences were not well simulated...... are affected by a common underlying mechanism, presumably related to cochlear outer hair cell function. The results also suggest that normal peripheral compression remains strong even at 250 Hz....

  8. Image and video compression for HDR content

    Science.gov (United States)

    Zhang, Yang; Reinhard, Erik; Agrafiotis, Dimitris; Bull, David R.

    2012-10-01

    High Dynamic Range (HDR) technology can offer high levels of immersion with a dynamic range meeting and exceeding that of the Human Visual System (HVS). A primary drawback with HDR images and video is that memory and bandwidth requirements are significantly higher than for conventional images and video. Many bits can be wasted coding redundant imperceptible information. The challenge is therefore to develop means for efficiently compressing HDR imagery to a manageable bit rate without compromising perceptual quality. In this paper, we build on previous work of ours and propose a compression method for both HDR images and video, based on an HVS optimised wavelet subband weighting method. The method has been fully integrated into a JPEG 2000 codec for HDR image compression and implemented as a pre-processing step for HDR video coding (an H.264 codec is used as the host codec for video compression). Experimental results indicate that the proposed method outperforms previous approaches and operates in accordance with characteristics of the HVS, tested objectively using a HDR Visible Difference Predictor (VDP). Aiming to further improve the compression performance of our method, we additionally present the results of a psychophysical experiment, carried out with the aid of a high dynamic range display, to determine the difference in the noise visibility threshold between HDR and Standard Dynamic Range (SDR) luminance edge masking. Our findings show that noise has increased visibility on the bright side of a luminance edge. Masking is more consistent on the darker side of the edge.

  9. The compressed word problem for groups

    CERN Document Server

    Lohrey, Markus

    2014-01-01

    The Compressed Word Problem for Groups provides a detailed exposition of known results on the compressed word problem, emphasizing efficient algorithms for the compressed word problem in various groups. The author presents the necessary background along with the most recent results on the compressed word problem to create a cohesive self-contained book accessible to computer scientists as well as mathematicians. Readers will quickly reach the frontier of current research which makes the book especially appealing for students looking for a currently active research topic at the intersection of group theory and computer science. The word problem introduced in 1910 by Max Dehn is one of the most important decision problems in group theory. For many groups, highly efficient algorithms for the word problem exist. In recent years, a new technique based on data compression for providing more efficient algorithms for word problems, has been developed, by representing long words over group generators in a compres...

  10. Mechanical compression attenuates normal human bronchial epithelial wound healing

    Directory of Open Access Journals (Sweden)

    Malavia Nikita

    2009-02-01

    Full Text Available Abstract Background Airway narrowing associated with chronic asthma results in the transmission of injurious compressive forces to the bronchial epithelium and promotes the release of pro-inflammatory mediators and the denudation of the bronchial epithelium. While the individual effects of compression or denudation are well characterized, there is no data to elucidate how these cells respond to the application of mechanical compression in the presence of a compromised epithelial layer. Methods Accordingly, differentiated normal human bronchial epithelial cells were exposed to one of four conditions: 1 unperturbed control cells, 2 single scrape wound only, 3 static compression (6 hours of 30 cmH2O, and 4 6 hours of static compression after a scrape wound. Following treatment, wound closure rate was recorded, media was assayed for mediator content and the cytoskeletal network was fluorescently labeled. Results We found that mechanical compression and scrape injury increase TGF-β2 and endothelin-1 secretion, while EGF content in the media is attenuated with both injury modes. The application of compression after a pre-existing scrape wound augmented these observations, and also decreased PGE2 media content. Compression stimulated depolymerization of the actin cytoskeleton and significantly attenuated wound healing. Closure rate was partially restored with the addition of exogenous PGE2, but not EGF. Conclusion Our results suggest that mechanical compression reduces the capacity of the bronchial epithelium to close wounds, and is, in part, mediated by PGE2 and a compromised cytoskeleton.

  11. Bunch Compression Stability Dependence on RF Parameters

    CERN Document Server

    Limberg, T

    2005-01-01

    In present designs for FEL's with high electron peak currents and short bunch lengths, higher harmonic RF systems are often used to optimize the final longitudinal charge distributions. This opens degrees of freedom for the choice of RF phases and amplitudes to achieve the necessary peak current with a reasonable longitudinal bunch shape. It had been found empirically that different working points result in different tolerances for phases and amplitudes. We give an analytical expression for the sensitivity of the compression factor on phase and amplitude jitter for a bunch compression scheme involving two RF systems and two magnetic chicanes as well numerical results for the case of the European XFEL.

  12. Time-resolved Sensing of Meso-scale Shock Compression with Multilayer Photonic Crystal Structures

    Science.gov (United States)

    Scripka, David; Lee, Gyuhyon; Summers, Christopher J.; Thadhani, Naresh

    2017-06-01

    Multilayer Photonic Crystal structures can provide spatially and temporally resolved data needed to validate theoretical and computational models relevant for understanding shock compression in heterogeneous materials. Two classes of 1-D photonic crystal multilayer structures were studied: optical microcavities (OMC) and distributed Bragg reflectors (DBR). These 0.5 to 5 micron thick structures were composed of SiO2, Al2O3, Ag, and PMMA layers fabricated primarily via e-beam evaporation. The multilayers have unique spectral signatures inherently linked to their time-resolved physical states. By observing shock-induced changes in these signatures, an optically-based pressure sensor was developed. Results to date indicate that both OMCs and DBRs exhibit nanosecond-resolved spectral shifts of several to 10s of nanometers under laser-driven shock compression loads of 0-10 GPa, with the magnitude of the shift strongly correlating to the shock load magnitude. Additionally, spatially and temporally resolved spectral shifts under heterogeneous laser-driven shock compression created by partial beam blocking have been successfully demonstrated. These results illustrate the potential for multilayer structures to serve as meso-scale sensors, capturing temporal and spatial pressure profile evolutions in shock-compressed heterogeneous materials, and revealing meso-scale pressure distributions across a shocked surface. Supported by DTRA Grant HDTRA1-12-1-005 and DoD, AFOSR, National Defense Science and Eng. Graduate Fellowship, 32 CFR 168a.

  13. Effects of Oxide Layer Composition and Radial Compression on Nickel Release in Nitinol Stents

    Science.gov (United States)

    Sullivan, Stacey J. L.; Dreher, Maureen L.; Zheng, Jiwen; Chen, Lynn; Madamba, Daniel; Miyashiro, Katie; Trépanier, Christine; Nagaraja, Srinidhi

    2015-09-01

    There is a public health need to understand the effects of surface layer thickness and composition on corrosion in nickel-containing medical devices. To address this knowledge gap, five groups of Nitinol stents were manufactured by various processing methods that altered the titanium oxide layer. The following surfaces were created: >3500 nm thick mixed thermal oxide (OT), ~420 nm thick mixed thermal oxide (SP), ~130 nm thick mixed thermal oxide (AF), ~4 nm thick native oxide (MP), and an ~4 nm thick passivated oxide (EP). Radially compressed and not compressed devices were evaluated for nickel (Ni) ion release in a 60-day immersion test. The results indicated that OT stents released the most Ni, followed by stents in the SP and AF groups. For OT and SP stents, which exhibited the thickest oxide layers, radial compression significantly increased Ni release when compared to non-compressed stents. This result was not observed in AF, MP, SP stents indicating that the increased Ni release may be explained by cracking of the thicker oxide layers during crimping. Strong correlations were observed between oxide layer thickness and cumulative Ni release. These findings elucidate the importance of oxide layer thickness and composition on uniform corrosion of laser-cut Nitinol stents.

  14. Behavior of concrete cylinders confined by a ferro-geopolymer jacket in axial compression

    Directory of Open Access Journals (Sweden)

    Kothay Heng

    2017-06-01

    Full Text Available It is beneficial to utilize geopolymers for their potential properties to rehabilitate concrete structures. These properties include high adhesion to Ordinary Portland Cement (OPC concrete even at low degrees of interfacial roughness, high durability and good fire resistance. This paper introduces use of a ferro-geopolymer jacket to strengthen concrete columns. It is a kind of jacket constructed with a geopolymer mortar reinforced with a wire mesh. This study was conducted to investigate the behavior of concrete cylinders confined with a ferro-geopolymer jacket in axial compression. OPC concrete cylinders with 100 mm diameter and 200 mm height were fabricated. High calcium fly ash-based geopolymer mortar, activated with sodium hydroxide (NaOH and sodium silicate (Na2SiO3, cured at a temperature of 25 ºC was used. Ferro-geopolymer jackets with a25 mm thickness, were reinforced with 1, 2 and 3 layers of expanded metal mesh and cast around concrete cylinders. The study results revealed that the compressive load carrying capacity and axial stiffness of concrete cylinders were improved. A monolithic failure mode was obtained as a result of a strong adhesion between the geopolymer and the concrete core. Enhancement of compressive load carrying capacity of the jacketed concrete cylinders was caused by a combination of a confinement effect and the compressive load resistance of the jacket transferred from concrete core through bonding.

  15. Compression-rate-dependent nonlinear mechanics of normal and impaired porcine knee joints.

    Science.gov (United States)

    Rodriguez, Marcel Leonardo; Li, LePing

    2017-11-14

    The knee joint performs mechanical functions with various loading and unloading processes. Past studies have focused on the kinematics and elastic response of the joint with less understanding of the rate-dependent load response associated with viscoelastic and poromechanical behaviors. Forty-five fresh porcine knee joints were used in the present study to determine the loading-rate-dependent force-compression relationship, creep and relaxation of normal, dehydrated and meniscectomized joints. The mechanical tests of all normal intact joints showed similar strong compression-rate-dependent behavior: for a given compression-magnitude up to 1.2 mm, the reaction force varied 6 times over compression rates. While the static response was essentially linear, the nonlinear behavior was boosted with the increased compression rate to approach the asymptote or limit at approximately 2 mm/s. On the other hand, the joint stiffness varied approximately 3 times over different joints, when accounting for the maturity and breed of the animals. Both a loss of joint hydration and a total meniscectomy greatly compromised the load support in the joint, resulting in a reduction of load support as much as 60% from the corresponding intact joint. However, the former only weakened the transient load support, but the latter also greatly weakened the equilibrium load support. A total meniscectomy did not diminish the compression-rate-dependence of the joint though. These findings are consistent with the fluid-pressurization loading mechanism, which may have a significant implication in the joint mechanical function and cartilage mechanobiology.

  16. Strong stabilization of the Rayleigh-Taylor instability by material strength at Mbar pressures

    Energy Technology Data Exchange (ETDEWEB)

    Park, H S; Lorenz, K T; Cavallo, R M; Pollaine, S M; Prisbrey, S T; Rudd, R E; Becker, R C; Bernier, J V; Remington, B A

    2009-11-19

    Experimental results showing significant reductions from classical in the Rayleigh-Taylor (RT) instability growth rate due to high pressure effective lattice viscosity are presented. Using a laser created ramped drive, vanadium samples are compressed and accelerated quasi-isentropically at {approx}1 Mbar pressures, while maintaining the sample in the solid-state. Comparisons with simulations and theory indicate that the high pressure, high strain rate conditions trigger a phonon drag mechanism, resulting in the observed high effective lattice viscosity and strong stabilization of the RT instability.

  17. Strong interaction and QFD

    International Nuclear Information System (INIS)

    Ebata, T.

    1981-01-01

    With an assumed weak multiplet structure for bosonic hadrons, which is consistent with the ΔI = 1/2 rule, it is shown that the strong interaction effective hamiltonian is compatible with the weak SU(2) x U(1) gauge transformation. Especially the rho-meson transforms as a triplet under SU(2)sub(w), and this is the origin of the rho-photon analogy. It is also shown that the existence of the non-vanishing Cabibbo angle is a necessary condition for the absence of the exotic hadrons. (orig.)

  18. Statistical conditional sampling for variable-resolution video compression.

    Science.gov (United States)

    Wong, Alexander; Shafiee, Mohammad Javad; Azimifar, Zohreh

    2012-01-01

    In this study, we investigate a variable-resolution approach to video compression based on Conditional Random Field and statistical conditional sampling in order to further improve compression rate while maintaining high-quality video. In the proposed approach, representative key-frames within a video shot are identified and stored at full resolution. The remaining frames within the video shot are stored and compressed at a reduced resolution. At the decompression stage, a region-based dictionary is constructed from the key-frames and used to restore the reduced resolution frames to the original resolution via statistical conditional sampling. The sampling approach is based on the conditional probability of the CRF modeling by use of the constructed dictionary. Experimental results show that the proposed variable-resolution approach via statistical conditional sampling has potential for improving compression rates when compared to compressing the video at full resolution, while achieving higher video quality when compared to compressing the video at reduced resolution.

  19. Experiments of cylindrical isentropic compression by ultrahigh magnetic field

    Science.gov (United States)

    Gu, Zhuowei; Zhou, Zhongyu; Zhang, Chunbo; Tang, Xiaosong; Tong, Yanjin; Zhao, Jianheng; Sun, Chengwei

    2015-09-01

    The high Explosive Magnetic Flux Implosion Compression Generator (EMFICG) is a kind of unique high energy density dynamic technique with characters like ultrahigh pressure and low temperature rising and could be suitable as a tool of cylindrical isentropic compression. The Institute of Fluid Physics, Chinese Academy of Engineering Physics (IFP, CAEP) have developed EMFICG technique and realized cylindrical isentropic compression. In the experiments, a seed magnetic field of 5-6 Tesla were built first and compressed by a stainless steel liner which is driven by high explosive. The inner free surface velocity of sample was measured by PDV. The isentropic compression of a copper sample was verified and the isentropic pressure is over 100 GPa. The cylindrical isentropic compression process has been numerical simulated by 1D MHD code and the simulation results were compared with the experiments. Compared with the transitional X-ray flash radiograph measurement, this method will probably promote the data accuracy.

  20. Experiments of cylindrical isentropic compression by ultrahigh magnetic field

    Directory of Open Access Journals (Sweden)

    Gu Zhuowei

    2015-01-01

    Full Text Available The high Explosive Magnetic Flux Implosion Compression Generator (EMFICG is a kind of unique high energy density dynamic technique with characters like ultrahigh pressure and low temperature rising and could be suitable as a tool of cylindrical isentropic compression. The Institute of Fluid Physics, Chinese Academy of Engineering Physics (IFP, CAEP have developed EMFICG technique and realized cylindrical isentropic compression. In the experiments, a seed magnetic field of 5–6 Tesla were built first and compressed by a stainless steel liner which is driven by high explosive. The inner free surface velocity of sample was measured by PDV. The isentropic compression of a copper sample was verified and the isentropic pressure is over 100 GPa. The cylindrical isentropic compression process has been numerical simulated by 1D MHD code and the simulation results were compared with the experiments. Compared with the transitional X-ray flash radiograph measurement, this method will probably promote the data accuracy.

  1. Temporal compression in episodic memory for real-life events.

    Science.gov (United States)

    Jeunehomme, Olivier; Folville, Adrien; Stawarczyk, David; Van der Linden, Martial; D'Argembeau, Arnaud

    2017-11-25

    Remembering an event typically takes less time than experiencing it, suggesting that episodic memory represents past experience in a temporally compressed way. Little is known, however, about how the continuous flow of real-life events is summarised in memory. Here we investigated the nature and determinants of temporal compression by directly comparing memory contents with the objective timing of events as measured by a wearable camera. We found that episodic memories consist of a succession of moments of prior experience that represent events with varying compression rates, such that the density of retrieved information is modulated by goal processing and perceptual changes. Furthermore, the results showed that temporal compression rates remain relatively stable over one week and increase after a one-month delay, particularly for goal-related events. These data shed new light on temporal compression in episodic memory and suggest that compression rates are adaptively modulated to maintain current goal-relevant information.

  2. Compression Characteristics of Solid Wastes as Backfill Materials

    Directory of Open Access Journals (Sweden)

    Meng Li

    2016-01-01

    Full Text Available A self-made large-diameter compression steel chamber and a SANS material testing machine were chosen to perform a series of compression tests in order to fully understand the compression characteristics of differently graded filling gangue samples. The relationship between the stress-deformation modulus and stress-compression degree was analyzed comparatively. The results showed that, during compression, the deformation modulus of gangue grew linearly with stress, the overall relationship between stress and compression degree was approximately nonlinear, and the deformation of gangue was rather large during the initial portion of the test. Gangue sample mixed with Talbot Formula provides the best deformation resistance capacity, followed by fully graded and single-graded gangue samples. For applications, with adjustment of the gradation of filling materials and optimal design of compacting equipment, surface subsidence may be better controlled.

  3. Anisotropy and compression/tension asymmetry of PP containing soft and hard particles and short glass fibers

    Directory of Open Access Journals (Sweden)

    A. M. Hartl

    2015-07-01

    Full Text Available Polypropylene (PP composites are used in a wide range of structural applications. Except for fiber reinforced PP, most PP particle composites are commonly considered to be isotropic or at least quasi-isotropic. In this paper, however, the anisotropy of several PP composites containing soft (rubber and hard (talc particles and glass fibers is characterized in detail in terms of the material microstructure as well as the resulting mechanical properties in monotonic tensile and compressive experiments. The microstructural investigations showed that all composites displayed a certain surface-core layer structure of distinctly different orientation patterns and with a higher degree of orientation in the surface layer. Also in mechanical testing an anisotropic behavior was observed with the degree of anisotropy being more pronounced in tension than compression. Moreover, the compression/tension asymmetry also strongly depends on filler type and orientation.

  4. Delamination of Compressed Thin Layers at Corners

    DEFF Research Database (Denmark)

    Sørensen, Kim D.; Jensen, Henrik Myhre; Clausen, Johan

    2008-01-01

    An analysis of delamination for a thin elastic layer under compression, attached to a substrate at a corner is carried out. The analysis is performed by combining results from interface fracture mechanics and the theory of thin shells. In contrast with earlier results for delamination on a flat...

  5. Strong Coupling Holography

    CERN Document Server

    Dvali, Gia

    2009-01-01

    We show that whenever a 4-dimensional theory with N particle species emerges as a consistent low energy description of a 3-brane embedded in an asymptotically-flat (4+d)-dimensional space, the holographic scale of high-dimensional gravity sets the strong coupling scale of the 4D theory. This connection persists in the limit in which gravity can be consistently decoupled. We demonstrate this effect for orbifold planes, as well as for the solitonic branes and string theoretic D-branes. In all cases the emergence of a 4D strong coupling scale from bulk holography is a persistent phenomenon. The effect turns out to be insensitive even to such extreme deformations of the brane action that seemingly shield 4D theory from the bulk gravity effects. A well understood example of such deformation is given by large 4D Einstein term in the 3-brane action, which is known to suppress the strength of 5D gravity at short distances and change the 5D Newton's law into the four-dimensional one. Nevertheless, we observe that the ...

  6. Fatigue Properties of Plain Concrete under Triaxial Tension-Compression-Compression Cyclic Loading

    Directory of Open Access Journals (Sweden)

    Dongfu Zhao

    2017-01-01

    Full Text Available Fatigue tests were performed on plain concrete under triaxial tension-compression-compression (T-C-C cyclic loading with constant and variable amplitude using a large multiaxial machine. Experimental results show that, under constant amplitude fatigue loads, the development of residual strain in the fatigue loading direction depends mostly on the lateral compressive stress ratio and is nearly independent of stress level. Under variable amplitude fatigue loads, the fatigue residual strain is related to the relative fatigue cycle and lateral compressive stress ratio but has little relationship with the loading process. To model this system, the relative residual strain was defined as the damage variant. Damage evolutions for plain concrete were established. In addition, fatigue damage analysis and predictions of fatigue remaining life were conducted. This work provides a reference for multistage fatigue testing and fatigue damage evaluation of plain concrete under multiaxial loads.

  7. Perceptual Effects of Dynamic Range Compression in Popular Music Recordings

    DEFF Research Database (Denmark)

    Hjortkjær, Jens; Walther-Hansen, Mads

    2014-01-01

    The belief that the use of dynamic range compression in music mastering deteriorates sound quality needs to be formally tested. In this study normal hearing listeners were asked to evaluate popular music recordings in original versions and in remastered versions with higher levels of dynamic range...... compression. Surprisingly, the results failed to reveal any evidence of the effects of dynamic range compression on subjective preference or perceived depth cues. Perceptual data suggest that listeners are less sensitive than commonly believed to even high levels of compression. As measured in terms...

  8. KRESKA: A compression system for small and very large images

    Science.gov (United States)

    Ohnesorge, Krystyna W.; Sennhauser, Rene

    1995-01-01

    An effective lossless compression system for grayscale images is presented using finite context variable order Markov models. A new method to accurately estimate the probability of the escape symbol is proposed. The choice of the best model order and rules for selecting context pixels are discussed. Two context precision and two symbol precision techniques to handle noisy image data with Markov models are introduced. Results indicate that finite context variable order Markov models lead to effective lossless compression systems for small and very large images. The system achieves higher compression ratios than some of the better known image compression techniques such as lossless JPEG, JBIG, or FELICS.

  9. Scattering of sound waves by a compressible vortex

    Science.gov (United States)

    Colonius, Tim; Lele, Sanjiva K.; Moin, Parviz

    1991-01-01

    Scattering of plane sound waves by a compressible vortex is investigated by direct computation of the two-dimensional Navier-Stokes equations. Nonreflecting boundary conditions are utilized, and their accuracy is established by comparing results on different sized domains. Scattered waves are directly measured from the computations. The resulting amplitude and directivity pattern of the scattered waves is discussed, and compared to various theoretical predictions. For compact vortices (zero circulation), the scattered waves directly computed are in good agreement with predictions based on an acoustic analogy. Strong scattering at about + or - 30 degrees from the direction of incident wave propagation is observed. Back scattering is an order of magnitude smaller than forward scattering. For vortices with finite circulation refraction of the sound by the mean flow field outside the vortex core is found to be important in determining the amplitude and directivity of the scattered wave field.

  10. Homogeneous Charge Compression Ignition Combustion of Dimethyl Ether

    DEFF Research Database (Denmark)

    Pedersen, Troels Dyhr

    before the fuel is burned completely, due to lower in-cylinder temperatures and lower reaction rates. The study provided some insight in the importance of operating at the correct compression ratio, as well as the operational limitations and emission characteristics of HCCI combustion. HCCI combustion...... temperature reactions with reasonable similarity to the original mechanism. By reducing the mechanism to its essential reactions it becomes more useful to CFD models of HCCI combustion. The number of elementary reactions has a great influence on computational demands and computing time, so the use of a simple...... pressure gradients result from the combustion. These pressure gradients cause strong acoustic resonance in the combustion chamber. Part of the energy from this resonance is transferred to the cylinder liner and further through the engine block. The engine vibrates both as a result of direct transmission...

  11. Mammographic compression in Asian women.

    Directory of Open Access Journals (Sweden)

    Susie Lau

    Full Text Available To investigate: (1 the variability of mammographic compression parameters amongst Asian women; and (2 the effects of reducing compression force on image quality and mean glandular dose (MGD in Asian women based on phantom study.We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35-80 years who underwent screening or diagnostic mammography between Jan 2012 and Dec 2014 at our center. The mammograms were processed using a volumetric breast density (VBD measurement software (Volpara to assess compression force, compression pressure, compressed breast thickness (CBT, breast volume, VBD and MGD against breast contact area. The effects of reducing compression force on image quality and MGD were also evaluated based on measurement obtained from 105 Asian women, as well as using the RMI156 Mammographic Accreditation Phantom and polymethyl methacrylate (PMMA slabs.Compression force, compression pressure, CBT, breast volume, VBD and MGD correlated significantly with breast contact area (p0.05.Force-standardized protocol led to widely variable compression parameters in Asian women. Based on phantom study, it is feasible to reduce compression force up to 32.5% with minimal effects on image quality and MGD.

  12. Remote sensing image compression assessment based on multilevel distortions

    Science.gov (United States)

    Jiang, Hongxu; Yang, Kai; Liu, Tingshan; Zhang, Yongfei

    2014-01-01

    The measurement of visual quality is of fundamental importance to remote sensing image compression, especially for image quality assessment and compression algorithm optimization. We exploit the distortion features of optical remote sensing image compression and propose a full-reference image quality metric based on multilevel distortions (MLD), which assesses image quality by calculating distortions of three levels (such as pixel-level, contexture-level, and content-level) between original images and compressed images. Based on this, a multiscale MLD (MMLD) algorithm is designed and it outperforms the other current methods in our testing. In order to validate the performance of our algorithm, a special remote sensing image compression distortion (RICD) database is constructed, involving 250 remote sensing images compressed with different algorithms and various distortions. Experimental results on RICD and Laboratory for Image and Video Engineering databases show that the proposed MMLD algorithm has better consistency with subjective perception values than current state-of-the-art methods in remote sensing image compression assessment, and the objective assessment results can show the distortion features and visual quality of compressed image well. It is suitable to be the evaluation criteria for optical remote sensing image compression.

  13. High Bit-Depth Medical Image Compression With HEVC.

    Science.gov (United States)

    Parikh, Saurin S; Ruiz, Damian; Kalva, Hari; Fernandez-Escribano, Gerardo; Adzic, Velibor

    2018-03-01

    Efficient storing and retrieval of medical images has direct impact on reducing costs and improving access in cloud-based health care services. JPEG 2000 is currently the commonly used compression format for medical images shared using the DICOM standard. However, new formats such as high efficiency video coding (HEVC) can provide better compression efficiency compared to JPEG 2000. Furthermore, JPEG 2000 is not suitable for efficiently storing image series and 3-D imagery. Using HEVC, a single format can support all forms of medical images. This paper presents the use of HEVC for diagnostically acceptable medical image compression, focusing on compression efficiency compared to JPEG 2000. Diagnostically acceptable lossy compression and complexity of high bit-depth medical image compression are studied. Based on an established medically acceptable compression range for JPEG 2000, this paper establishes acceptable HEVC compression range for medical imaging applications. Experimental results show that using HEVC can increase the compression performance, compared to JPEG 2000, by over 54%. Along with this, a new method for reducing computational complexity of HEVC encoding for medical images is proposed. Results show that HEVC intra encoding complexity can be reduced by over 55% with negligible increase in file size.

  14. Analysis by compression

    DEFF Research Database (Denmark)

    Meredith, David

    MEL is a geometric music encoding language designed to allow for musical objects to be encoded parsimoniously as sets of points in pitch-time space, generated by performing geometric transformations on component patterns. MEL has been implemented in Java and coupled with the SIATEC pattern discov...... discovery algorithm to allow for compact encodings to be generated automatically from in extenso note lists. The MEL-SIATEC system is founded on the belief that music analysis and music perception can be modelled as the compression of in extenso descriptions of musical objects....

  15. Compressive full waveform lidar

    Science.gov (United States)

    Yang, Weiyi; Ke, Jun

    2017-05-01

    To avoid high bandwidth detector, fast speed A/D converter, and large size memory disk, a compressive full waveform LIDAR system, which uses a temporally modulated laser instead of a pulsed laser, is studied in this paper. Full waveform data from NEON (National Ecological Observatory Network) are used. Random binary patterns are used to modulate the source. To achieve 0.15 m ranging resolution, a 100 MSPS A/D converter is assumed to make measurements. SPIRAL algorithm with canonical basis is employed when Poisson noise is considered in the low illuminated condition.

  16. Compression test apparatus

    Science.gov (United States)

    Shanks, G. C. (Inventor)

    1981-01-01

    An apparatus for compressive testing of a test specimen may comprise vertically spaced upper and lower platen members between which a test specimen may be placed. The platen members are supported by a fixed support assembly. A load indicator is interposed between the upper platen member and the support assembly for supporting the total weight of the upper platen member and any additional weight which may be placed on it. Operating means are provided for moving the lower platen member upwardly toward the upper platen member whereby an increasing portion of the total weight is transferred from the load indicator to the test specimen.

  17. Compressive Fatigue in Wood

    DEFF Research Database (Denmark)

    Clorius, Christian Odin; Pedersen, Martin Bo Uhre; Hoffmeyer, Preben

    1999-01-01

    An investigation of fatigue failure in wood subjected to load cycles in compression parallel to grain is presented. Small clear specimens of spruce are taken to failure in square wave formed fatigue loading at a stress excitation level corresponding to 80% of the short term strength. Four...... frequencies ranging from 0.01 Hz to 10 Hz are used. The number of cycles to failure is found to be a poor measure of the fatigue performance of wood. Creep, maximum strain, stiffness and work are monitored throughout the fatigue tests. Accumulated creep is suggested identified with damage and a correlation...

  18. Metal Hydride Compression

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Terry A. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Bowman, Robert [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Smith, Barton [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Anovitz, Lawrence [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jensen, Craig [Hawaii Hydrogen Carriers LLC, Honolulu, HI (United States)

    2017-07-01

    Conventional hydrogen compressors often contribute over half of the cost of hydrogen stations, have poor reliability, and have insufficient flow rates for a mature FCEV market. Fatigue associated with their moving parts including cracking of diaphragms and failure of seal leads to failure in conventional compressors, which is exacerbated by the repeated starts and stops expected at fueling stations. Furthermore, the conventional lubrication of these compressors with oil is generally unacceptable at fueling stations due to potential fuel contamination. Metal hydride (MH) technology offers a very good alternative to both conventional (mechanical) and newly developed (electrochemical, ionic liquid pistons) methods of hydrogen compression. Advantages of MH compression include simplicity in design and operation, absence of moving parts, compactness, safety and reliability, and the possibility to utilize waste industrial heat to power the compressor. Beyond conventional H2 supplies of pipelines or tanker trucks, another attractive scenario is the on-site generating, pressuring and delivering pure H2 at pressure (≥ 875 bar) for refueling vehicles at electrolysis, wind, or solar generating production facilities in distributed locations that are too remote or widely distributed for cost effective bulk transport. MH hydrogen compression utilizes a reversible heat-driven interaction of a hydride-forming metal alloy with hydrogen gas to form the MH phase and is a promising process for hydrogen energy applications [1,2]. To deliver hydrogen continuously, each stage of the compressor must consist of multiple MH beds with synchronized hydrogenation & dehydrogenation cycles. Multistage pressurization allows achievement of greater compression ratios using reduced temperature swings compared to single stage compressors. The objectives of this project are to investigate and demonstrate on a laboratory scale a two-stage MH hydrogen (H2) gas compressor with a

  19. Virtually Lossless Compression of Astrophysical Images

    Directory of Open Access Journals (Sweden)

    Stefano Baronti

    2005-09-01

    Full Text Available We describe an image compression strategy potentially capable of preserving the scientific quality of astrophysical data, simultaneously allowing a consistent bandwidth reduction to be achieved. Unlike strictly lossless techniques, by which moderate compression ratios are attainable, and conventional lossy techniques, in which the mean square error of the decoded data is globally controlled by users, near-lossless methods are capable of locally constraining the maximum absolute error, based on user's requirements. An advanced lossless/near-lossless differential pulse code modulation (DPCM scheme, recently introduced by the authors and relying on a causal spatial prediction, is adjusted to the specific characteristics of astrophysical image data (high radiometric resolution, generally low noise, etc.. The background noise is preliminarily estimated to drive the quantization stage for high quality, which is the primary concern in most of astrophysical applications. Extensive experimental results of lossless, near-lossless, and lossy compression of astrophysical images acquired by the Hubble space telescope show the advantages of the proposed method compared to standard techniques like JPEG-LS and JPEG2000. Eventually, the rationale of virtually lossless compression, that is, a noise-adjusted lossles/near-lossless compression, is highlighted and found to be in accordance with concepts well established for the astronomers' community.

  20. Iris Recognition: The Consequences of Image Compression

    Directory of Open Access Journals (Sweden)

    Bishop DanielA

    2010-01-01

    Full Text Available Iris recognition for human identification is one of the most accurate biometrics, and its employment is expanding globally. The use of portable iris systems, particularly in law enforcement applications, is growing. In many of these applications, the portable device may be required to transmit an iris image or template over a narrow-bandwidth communication channel. Typically, a full resolution image (e.g., VGA is desired to ensure sufficient pixels across the iris to be confident of accurate recognition results. To minimize the time to transmit a large amount of data over a narrow-bandwidth communication channel, image compression can be used to reduce the file size of the iris image. In other applications, such as the Registered Traveler program, an entire iris image is stored on a smart card, but only 4 kB is allowed for the iris image. For this type of application, image compression is also the solution. This paper investigates the effects of image compression on recognition system performance using a commercial version of the Daugman iris2pi algorithm along with JPEG-2000 compression, and links these to image quality. Using the ICE 2005 iris database, we find that even in the face of significant compression, recognition performance is minimally affected.

  1. Design Point for a Spheromak Compression Experiment

    Science.gov (United States)

    Woodruff, Simon; Romero-Talamas, Carlos A.; O'Bryan, John; Stuber, James; Darpa Spheromak Team

    2015-11-01

    Two principal issues for the spheromak concept remain to be addressed experimentally: formation efficiency and confinement scaling. We are therefore developing a design point for a spheromak experiment that will be heated by adiabatic compression, utilizing the CORSICA and NIMROD codes as well as analytic modeling with target parameters R_initial =0.3m, R_final =0.1m, T_initial =0.2keV, T_final =1.8keV, n_initial =1019m-3 and n_final = 1021m-3, with radial convergence of C =3. This low convergence differentiates the concept from MTF with C =10 or more, since the plasma will be held in equilibrium throughout compression. We present results from CORSICA showing the placement of coils and passive structure to ensure stability during compression, and design of the capacitor bank needed to both form the target plasma and compress it. We specify target parameters for the compression in terms of plasma beta, formation efficiency and energy confinement. Work performed under DARPA grant N66001-14-1-4044.

  2. Text segmentation for MRC document compression.

    Science.gov (United States)

    Haneda, Eri; Bouman, Charles A

    2011-06-01

    The mixed raster content (MRC) standard (ITU-T T.44) specifies a framework for document compression which can dramatically improve the compression/quality tradeoff as compared to traditional lossy image compression algorithms. The key to MRC compression is the separation of the document into foreground and background layers, represented as a binary mask. Therefore, the resulting quality and compression ratio of a MRC document encoder is highly dependent upon the segmentation algorithm used to compute the binary mask. In this paper, we propose a novel multiscale segmentation scheme for MRC document encoding based upon the sequential application of two algorithms. The first algorithm, cost optimized segmentation (COS), is a blockwise segmentation algorithm formulated in a global cost optimization framework. The second algorithm, connected component classification (CCC), refines the initial segmentation by classifying feature vectors of connected components using an Markov random field (MRF) model. The combined COS/CCC segmentation algorithms are then incorporated into a multiscale framework in order to improve the segmentation accuracy of text with varying size. In comparisons to state-of-the-art commercial MRC products and selected segmentation algorithms in the literature, we show that the new algorithm achieves greater accuracy of text detection but with a lower false detection rate of nontext features. We also demonstrate that the proposed segmentation algorithm can improve the quality of decoded documents while simultaneously lowering the bit rate.

  3. Stretched versus compressed exponential kinetics in α-helix folding

    International Nuclear Information System (INIS)

    Hamm, Peter; Helbing, Jan; Bredenbeck, Jens

    2006-01-01

    In a recent paper (J. Bredenbeck, J. Helbing, J.R. Kumita, G.A. Woolley, P. Hamm, α-helix formation in a photoswitchable peptide tracked from picoseconds to microseconds by time resolved IR spectroscopy, Proc. Natl. Acad. Sci USA 102 (2005) 2379), we have investigated the folding of a photo-switchable α-helix with a kinetics that could be fit by a stretched exponential function exp(-(t/τ) β ). The stretching factor β became smaller as the temperature was lowered, a result which has been interpreted in terms of activated diffusion on a rugged energy surface. In the present paper, we discuss under which conditions diffusion problems occur with stretched exponential kinetics (β 1). We show that diffusion problems do have a strong tendency to yield stretched exponential kinetics, yet, that there are conditions (strong perturbation from equilibrium, performing the experiment in the folding direction) under which compressed exponential kinetics would be expected instead. We discuss the kinetics on free energy surfaces predicted by simple initiation-propagation models (zipper models) of α-helix folding, as well as by folding funnel models. We show that our recent experiment has been performed under condition for which models with strong downhill driving force, such as the zipper model, would predict compressed, rather than stretched exponential kinetics, in disagreement with the experimental observation. We therefore propose that the free energy surface along a reaction coordinate that governs the folding kinetics must be relatively flat and has a shape similar to a 1D golf course. We discuss how this conclusion can be unified with the thermodynamically well established zipper model by introducing an additional kinetic reaction coordinate

  4. Comparison of chest compression quality between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method during CPR.

    Science.gov (United States)

    Park, Sang-Sub

    2014-01-01

    The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p< 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p< 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p< 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).

  5. HVS-based medical image compression

    International Nuclear Information System (INIS)

    Kai Xie; Jie Yang; Min Zhuyue; Liang Lixiao

    2005-01-01

    Introduction: With the promotion and application of digital imaging technology in the medical domain, the amount of medical images has grown rapidly. However, the commonly used compression methods cannot acquire satisfying results. Methods: In this paper, according to the existed and stated experiments and conclusions, the lifting step approach is used for wavelet decomposition. The physical and anatomic structure of human vision is combined and the contrast sensitivity function (CSF) is introduced as the main research issue in human vision system (HVS), and then the main designing points of HVS model are presented. On the basis of multi-resolution analyses of wavelet transform, the paper applies HVS including the CSF characteristics to the inner correlation-removed transform and quantization in image and proposes a new HVS-based medical image compression model. Results: The experiments are done on the medical images including computed tomography (CT) and magnetic resonance imaging (MRI). At the same bit rate, the performance of SPIHT, with respect to the PSNR metric, is significantly higher than that of our algorithm. But the visual quality of the SPIHT-compressed image is roughly the same as that of the image compressed with our approach. Our algorithm obtains the same visual quality at lower bit rates and the coding/decoding time is less than that of SPIHT. Conclusions: The results show that under common objective conditions, our compression algorithm can achieve better subjective visual quality, and performs better than that of SPIHT in the aspects of compression ratios and coding/decoding time

  6. Adaptive compression of DICOM image data

    Science.gov (United States)

    Hludov, Sergei; Engel, Thomas; Meinel, Christoph

    1998-09-01

    In this article a method to classify digital images into three categories based on a provisional analysis of the image content and a subsequent compression with the help of a suitable algorithm of compression is proposed. To classify the images two parameters are used. The first parameter carries the frequency information about the image. It represents the mean of the absolute amplitude of the Wavelet coefficients in the high frequency parts of the spectrum. The second parameter is an indicator concerning information about the structure of the image. The second parameter is constituted through the entropy of the length of the segments in one line and the entropy of the length of the segments in one column. In this article the results for the check of those classification rules for DICOM images are given as a confirmation of the effectiveness of the method proposed. The implementation of the image classification algorithm and the compression algorithms in the modeling process is performed in JAVA.

  7. Transversely Compressed- and Restrained Shear Joints

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Hansen, Christian Skodborg

    2013-01-01

    Anchorage of FRP strengthening systems where the deformation perpendicular to the FRP material is restrained or a compressive force is applied on the strengthening, seems to provide ductility, increased utilization of the FRP and failure modes which can be controlled through the anchorage method....... This paper presents theoretical model which can predict the response of transversely compressed and restrained single- and double lap shear joints. The interface material model is based on a cohesive law in the shear-slip plane with a descending branch and a uniform frictional stress added due...... to the friction in the crack, emanating from the transverse pressure or restraint. The theoretical model is compared with experimental results from transversely compressed single- and double shear joints. Also theoretical predictions of a mechanical integrated sleeve-wedge anchorage load capacity are carried out...

  8. Speech Enhancement Based on Compressed Sensing Technology

    Directory of Open Access Journals (Sweden)

    Huiyan Xu

    2014-10-01

    Full Text Available Compressed sensing (CS is a sampled approach on signal sparsity-base, and it can effectively extract the information which is contained in the signal. This paper presents a noisy speech enhancement new method based on CS process. Algorithm uses a voice sparsity in the discrete fast Fourier transform (Fast Fourier transform, FFT, and complex domain observation matrix is designed, and the noisy speech compression measurement and de-noising are made by soft threshold, and the speech signal is sparsely reconstructed by separable approximation (Sparse Reconstruction by Separable Approximation, SpaRSA algorithm to restore, speech enhancement is improved. Experimental results show that the denoising compression reconstruction of the noisy signal is done in the algorithm, SNR margin is improved greatly, and the background noise can been more effectively suppressed.

  9. Compression syndrome of the left renal vein

    Energy Technology Data Exchange (ETDEWEB)

    Justich, E.

    1982-04-01

    Severe compression of the left renal vein produces a pressure gradient between it and the inferior vena cava and results in changes in haemodynamics. The cause of the narrowing is usually the aorta, less commonly the superior mesenteric artery. Compression of the left renal vein may be responsible for a number of abnormalities such as primary varicoceles, primary varices of the ovarian, renal, pelvic and ureteric veins on the left, the more frequent occurrence of unilateral renal vein thrombosis on the left and the development of renovascular hypertension. One hundred and twenty-three selective phlebograms of the left renal vein and CT examinations of this structure in a further 87 patients acting as a control group were carried out. The significance of compression of the left renal vein as an aetiological factor in the development of the above mentioned abnormalities is discussed.

  10. Error Resilient Video Compression Using Behavior Models

    Directory of Open Access Journals (Sweden)

    Jacco R. Taal

    2004-03-01

    Full Text Available Wireless and Internet video applications are inherently subjected to bit errors and packet errors, respectively. This is especially so if constraints on the end-to-end compression and transmission latencies are imposed. Therefore, it is necessary to develop methods to optimize the video compression parameters and the rate allocation of these applications that take into account residual channel bit errors. In this paper, we study the behavior of a predictive (interframe video encoder and model the encoders behavior using only the statistics of the original input data and of the underlying channel prone to bit errors. The resulting data-driven behavior models are then used to carry out group-of-pictures partitioning and to control the rate of the video encoder in such a way that the overall quality of the decoded video with compression and channel errors is optimized.

  11. Gmz: a Gml Compression Model for Webgis

    Science.gov (United States)

    Khandelwal, A.; Rajan, K. S.

    2017-09-01

    Geography markup language (GML) is an XML specification for expressing geographical features. Defined by Open Geospatial Consortium (OGC), it is widely used for storage and transmission of maps over the Internet. XML schemas provide the convenience to define custom features profiles in GML for specific needs as seen in widely popular cityGML, simple features profile, coverage, etc. Simple features profile (SFP) is a simpler subset of GML profile with support for point, line and polygon geometries. SFP has been constructed to make sure it covers most commonly used GML geometries. Web Feature Service (WFS) serves query results in SFP by default. But it falls short of being an ideal choice due to its high verbosity and size-heavy nature, which provides immense scope for compression. GMZ is a lossless compression model developed to work for SFP compliant GML files. Our experiments indicate GMZ achieves reasonably good compression ratios and can be useful in WebGIS based applications.

  12. Energy transfer in compressible turbulence

    Science.gov (United States)

    Bataille, Francoise; Zhou, YE; Bertoglio, Jean-Pierre

    1995-01-01

    This letter investigates the compressible energy transfer process. We extend a methodology developed originally for incompressible turbulence and use databases from numerical simulations of a weak compressible turbulence based on Eddy-Damped-Quasi-Normal-Markovian (EDQNM) closure. In order to analyze the compressible mode directly, the well known Helmholtz decomposition is used. While the compressible component has very little influence on the solenoidal part, we found that almost all of the compressible turbulence energy is received from its solenoidal counterpart. We focus on the most fundamental building block of the energy transfer process, the triadic interactions. This analysis leads us to conclude that, at low turbulent Mach number, the compressible energy transfer process is dominated by a local radiative transfer (absorption) in both inertial and energy containing ranges.

  13. Compressive sensing in medical imaging.

    Science.gov (United States)

    Graff, Christian G; Sidky, Emil Y

    2015-03-10

    The promise of compressive sensing, exploitation of compressibility to achieve high quality image reconstructions with less data, has attracted a great deal of attention in the medical imaging community. At the Compressed Sensing Incubator meeting held in April 2014 at OSA Headquarters in Washington, DC, presentations were given summarizing some of the research efforts ongoing in compressive sensing for x-ray computed tomography and magnetic resonance imaging systems. This article provides an expanded version of these presentations. Sparsity-exploiting reconstruction algorithms that have gained popularity in the medical imaging community are studied, and examples of clinical applications that could benefit from compressive sensing ideas are provided. The current and potential future impact of compressive sensing on the medical imaging field is discussed.

  14. Normalized Compression Distance of Multisets with Applications.

    Science.gov (United States)

    Cohen, Andrew R; Vitányi, Paul M B

    2015-08-01

    Pairwise normalized compression distance (NCD) is a parameter-free, feature-free, alignment-free, similarity metric based on compression. We propose an NCD of multisets that is also metric. Previously, attempts to obtain such an NCD failed. For classification purposes it is superior to the pairwise NCD in accuracy and implementation complexity. We cover the entire trajectory from theoretical underpinning to feasible practice. It is applied to biological (stem cell, organelle transport) and OCR classification questions that were earlier treated with the pairwise NCD. With the new method we achieved significantly better results. The theoretic foundation is Kolmogorov complexity.

  15. Normalized Compression Distance of Multisets with Applications

    Science.gov (United States)

    Cohen, Andrew R.; Vitányi, Paul M.B.

    2015-01-01

    Pairwise normalized compression distance (NCD) is a parameter-free, feature-free, alignment-free, similarity metric based on compression. We propose an NCD of multisets that is also metric. Previously, attempts to obtain such an NCD failed. For classification purposes it is superior to the pairwise NCD in accuracy and implementation complexity. We cover the entire trajectory from theoretical underpinning to feasible practice. It is applied to biological (stem cell, organelle transport) and OCR classification questions that were earlier treated with the pairwise NCD. With the new method we achieved significantly better results. The theoretic foundation is Kolmogorov complexity. PMID:26352998

  16. Quantifying porosity, compressibility and permeability in Shale

    DEFF Research Database (Denmark)

    Mbia, Ernest Ncha; Fabricius, Ida Lykke; Frykman, Peter

    The Fjerritslev Formation in the Norwegian-Danish Basin forms the main seal to Upper Triassic-Lower Jurassic sandstone reservoirs. In order to estimate rock properties Jurassic shale samples from deep onshore wells in Danish basin were studied. Mineralogical analysis based on X-ray diffractometry...... (NMR) show that, the MICP porosity is 9-10% points lower than HPMI and NMR porosity. Compressibility result shows that deep shale is stiffer in situ than normally assumed in geotechnical modelling and that static compressibility corresponds with dynamic one only at the begining of unloading stress...

  17. Free compression tube. Applications

    Science.gov (United States)

    Rusu, Ioan

    2012-11-01

    During the flight of vehicles, their propulsion energy must overcome gravity, to ensure the displacement of air masses on vehicle trajectory, to cover both energy losses from the friction between a solid surface and the air and also the kinetic energy of reflected air masses due to the impact with the flying vehicle. The flight optimization by increasing speed and reducing fuel consumption has directed research in the aerodynamics field. The flying vehicles shapes obtained through studies in the wind tunnel provide the optimization of the impact with the air masses and the airflow along the vehicle. By energy balance studies for vehicles in flight, the author Ioan Rusu directed his research in reducing the energy lost at vehicle impact with air masses. In this respect as compared to classical solutions for building flight vehicles aerodynamic surfaces which reduce the impact and friction with air masses, Ioan Rusu has invented a device which he named free compression tube for rockets, registered with the State Office for Inventions and Trademarks of Romania, OSIM, deposit f 2011 0352. Mounted in front of flight vehicles it eliminates significantly the impact and friction of air masses with the vehicle solid. The air masses come into contact with the air inside the free compression tube and the air-solid friction is eliminated and replaced by air to air friction.

  18. Compressive Sensing DNA Microarrays

    Directory of Open Access Journals (Sweden)

    Sheikh Mona A

    2009-01-01

    Full Text Available Compressive sensing microarrays (CSMs are DNA-based sensors that operate using group testing and compressive sensing (CS principles. In contrast to conventional DNA microarrays, in which each genetic sensor is designed to respond to a single target, in a CSM, each sensor responds to a set of targets. We study the problem of designing CSMs that simultaneously account for both the constraints from CS theory and the biochemistry of probe-target DNA hybridization. An appropriate cross-hybridization model is proposed for CSMs, and several methods are developed for probe design and CS signal recovery based on the new model. Lab experiments suggest that in order to achieve accurate hybridization profiling, consensus probe sequences are required to have sequence homology of at least 80% with all targets to be detected. Furthermore, out-of-equilibrium datasets are usually as accurate as those obtained from equilibrium conditions. Consequently, one can use CSMs in applications in which only short hybridization times are allowed.

  19. Exchange symmetry, fluctuation-compressibility relation, and thermodynamic potentials of quantum liquids.

    Science.gov (United States)

    Lim, Yu Rim; Park, Seong Jun; Song, Sanggeun; Yang, Gil-Suk; Yoon, Young-Gui; Kim, Ji-Hyun; Sung, Jaeyoung

    2014-06-01

    Liquid helium does not obey the Gibbs fluctuation-compressibility relation, which was noted more than six decades ago. However, still missing is a clear explanation of the reason for the deviation or the correct fluctuation-compressibility relation for the quantum liquid. Here we present the fluctuation-compressibility relation valid for any grand canonical system. Our result shows that the deviation from the Gibbs formula arises from a nonextensive part of thermodynamic potentials. The particle-exchange symmetry of many-body wave function of a strongly degenerate quantum gas is related to the thermodynamic extensivity of the system; a Bose gas does not always obey the Gibbs formula, while a Fermi gas does. Our fluctuation-compressibility relation works for classical systems as well as quantum systems. This work demonstrates that the application range of the Gibbs-Boltzmann statistical thermodynamics can be extended to encompass nonextensive open systems without introducing any postulate other than the principle of equal a priori probability.

  20. Compression garments and exercise: no influence of pressure applied.

    Science.gov (United States)

    Beliard, Samuel; Chauveau, Michel; Moscatiello, Timothée; Cros, François; Ecarnot, Fiona; Becker, François

    2015-03-01

    products.There are conflict results regarding the effects of wearing compression garments during exercise.There is a trend towards a beneficial effect of compression garments worn during recovery.

  1. Introduction to compressible fluid flow

    CERN Document Server

    Oosthuizen, Patrick H

    2013-01-01

    IntroductionThe Equations of Steady One-Dimensional Compressible FlowSome Fundamental Aspects of Compressible FlowOne-Dimensional Isentropic FlowNormal Shock WavesOblique Shock WavesExpansion Waves - Prandtl-Meyer FlowVariable Area FlowsAdiabatic Flow with FrictionFlow with Heat TransferLinearized Analysis of Two-Dimensional Compressible FlowsHypersonic and High-Temperature FlowsHigh-Temperature Gas EffectsLow-Density FlowsBibliographyAppendices

  2. Mammographic compression in Asian women.

    Science.gov (United States)

    Lau, Susie; Abdul Aziz, Yang Faridah; Ng, Kwan Hoong

    2017-01-01

    To investigate: (1) the variability of mammographic compression parameters amongst Asian women; and (2) the effects of reducing compression force on image quality and mean glandular dose (MGD) in Asian women based on phantom study. We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35-80 years who underwent screening or diagnostic mammography between Jan 2012 and Dec 2014 at our center. The mammograms were processed using a volumetric breast density (VBD) measurement software (Volpara) to assess compression force, compression pressure, compressed breast thickness (CBT), breast volume, VBD and MGD against breast contact area. The effects of reducing compression force on image quality and MGD were also evaluated based on measurement obtained from 105 Asian women, as well as using the RMI156 Mammographic Accreditation Phantom and polymethyl methacrylate (PMMA) slabs. Compression force, compression pressure, CBT, breast volume, VBD and MGD correlated significantly with breast contact area (pAsian women. The median compression force should be about 8.1 daN compared to the current 12.0 daN. Decreasing compression force from 12.0 daN to 9.0 daN increased CBT by 3.3±1.4 mm, MGD by 6.2-11.0%, and caused no significant effects on image quality (p>0.05). Force-standardized protocol led to widely variable compression parameters in Asian women. Based on phantom study, it is feasible to reduce compression force up to 32.5% with minimal effects on image quality and MGD.

  3. Powder compression mechanics of spray-dried lactose nanocomposites.

    Science.gov (United States)

    Hellrup, Joel; Nordström, Josefina; Mahlin, Denny

    2017-02-25

    The aim of this study was to investigate the structural impact of the nanofiller incorporation on the powder compression mechanics of spray-dried lactose. The lactose was co-spray-dried with three different nanofillers, that is, cellulose nanocrystals, sodium montmorillonite and fumed silica, which led to lower micron-sized nanocomposite particles with varying structure and morphology. The powder compression mechanics of the nanocomposites and physical mixtures of the neat spray-dried components were evaluated by a rational evaluation method with compression analysis as a tool, using the Kawakita equation and the Shapiro-Konopicky-Heckel equation. Particle rearrangement dominated the initial compression profiles due to the small particle size of the materials. The strong contribution of particle rearrangement in the materials with fumed silica continued throughout the whole compression profile, which prohibited an in-depth material characterization. However, the lactose/cellulose nanocrystals and the lactose/sodium montmorillonite nanocomposites demonstrated high yield pressure compared with the physical mixtures indicating increased particle hardness upon composite formation. This increase has likely to do with a reinforcement of the nanocomposite particles by skeleton formation of the nanoparticles. In summary, the rational evaluation of mechanical properties done by applying powder compression analysis proved to be a valuable tool for mechanical evaluation for this type of spray-dried composite materials, unless they demonstrate particle rearrangement throughout the whole compression profile. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. A checkpoint compression study for high-performance computing systems

    Energy Technology Data Exchange (ETDEWEB)

    Ibtesham, Dewan [Univ. of New Mexico, Albuquerque, NM (United States). Dept. of Computer Science; Ferreira, Kurt B. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Scalable System Software Dept.; Arnold, Dorian [Univ. of New Mexico, Albuquerque, NM (United States). Dept. of Computer Science

    2015-02-17

    As high-performance computing systems continue to increase in size and complexity, higher failure rates and increased overheads for checkpoint/restart (CR) protocols have raised concerns about the practical viability of CR protocols for future systems. Previously, compression has proven to be a viable approach for reducing checkpoint data volumes and, thereby, reducing CR protocol overhead leading to improved application performance. In this article, we further explore compression-based CR optimization by exploring its baseline performance and scaling properties, evaluating whether improved compression algorithms might lead to even better application performance and comparing checkpoint compression against and alongside other software- and hardware-based optimizations. Our results highlights are: (1) compression is a very viable CR optimization; (2) generic, text-based compression algorithms appear to perform near optimally for checkpoint data compression and faster compression algorithms will not lead to better application performance; (3) compression-based optimizations fare well against and alongside other software-based optimizations; and (4) while hardware-based optimizations outperform software-based ones, they are not as cost effective.

  5. Energy Transfer and Triadic Interactions in Compressible Turbulence

    Science.gov (United States)

    Bataille, F.; Zhou, Ye; Bertoglio, Jean-Pierre

    1997-01-01

    Using a two-point closure theory, the Eddy-Damped-Quasi-Normal-Markovian (EDQNM) approximation, we have investigated the energy transfer process and triadic interactions of compressible turbulence. In order to analyze the compressible mode directly, the Helmholtz decomposition is used. The following issues were addressed: (1) What is the mechanism of energy exchange between the solenoidal and compressible modes, and (2) Is there an energy cascade in the compressible energy transfer process? It is concluded that the compressible energy is transferred locally from the solenoidal part to the compressible part. It is also found that there is an energy cascade of the compressible mode for high turbulent Mach number (M(sub t) greater than or equal to 0.5). Since we assume that the compressibility is weak, the magnitude of the compressible (radiative or cascade) transfer is much smaller than that of solenoidal cascade. These results are further confirmed by studying the triadic energy transfer function, the most fundamental building block of the energy transfer.

  6. High-energy few-cycle pulse compression through self-channeling in gases

    International Nuclear Information System (INIS)

    Hauri, C.; Merano, M.; Trisorio, A.; Canova, F.; Canova, L.; Lopez-Martens, R.; Ruchon, T.; Engquist, A.; Varju, K.; Gustafsson, E.

    2006-01-01

    Complete test of publication follows. Nonlinear spectral broadening of femtosecond optical pulses by intense propagation in a Kerr medium followed by temporal compression constitutes the Holy Grail for ultrafast science since it allows the generation of intense few-cycle optical transients from longer pulses provided by now commercially available femtosecond lasers. Tremendous progress in high-field and attosecond physics achieved in recent years has triggered the need for efficient pulse compression schemes producing few-cycle pulses beyond the mJ level. We studied a novel pulse compression scheme based on self-channeling in gases, which promises to overcome the energy constraints of hollow-core fiber compression techniques. Fundamentally, self-channeling at high laser powers in gases occurs when the self-focusing effect in the gas is balanced through the dispersion induced by the inhomogeneous refractive index resulting from optically-induced ionization. The high nonlinearity of the ionization process poses great technical challenges when trying to scale this pulse compression scheme to higher energies input energies. Light channels are known to be unstable under small fluctuations of the trapped field that can lead to temporal and spatial beam breakup, usually resulting in the generation of spectrally broad but uncompressible pulses. Here we present experimental results on high-energy pulse compression of self-channeled 40-fs pulses in pressure-gas cells. In the first experiment, performed at the Lund Laser Center in Sweden, we identified a particular self-channeling regime at lower pulse energies (0.8 mJ), in which the ultrashort pulses are generated with negative group delay dispersion (GDD) such that they can be readily compressed down to near 10-fs through simple material dispersion. Pulse compression is efficient (70%) and exhibits exceptional spatial and temporal beam stability. In a second experiment, performed at the LOA-Palaiseau in France, we

  7. Authenticity examination of compressed audio recordings using detection of multiple compression and encoders' identification.

    Science.gov (United States)

    Korycki, Rafal

    2014-05-01

    Since the appearance of digital audio recordings, audio authentication has been becoming increasingly difficult. The currently available technologies and free editing software allow a forger to cut or paste any single word without audible artifacts. Nowadays, the only method referring to digital audio files commonly approved by forensic experts is the ENF criterion. It consists in fluctuation analysis of the mains frequency induced in electronic circuits of recording devices. Therefore, its effectiveness is strictly dependent on the presence of mains signal in the recording, which is a rare occurrence. Recently, much attention has been paid to authenticity analysis of compressed multimedia files and several solutions were proposed for detection of double compression in both digital video and digital audio. This paper addresses the problem of tampering detection in compressed audio files and discusses new methods that can be used for authenticity analysis of digital recordings. Presented approaches consist in evaluation of statistical features extracted from the MDCT coefficients as well as other parameters that may be obtained from compressed audio files. Calculated feature vectors are used for training selected machine learning algorithms. The detection of multiple compression covers up tampering activities as well as identification of traces of montage in digital audio recordings. To enhance the methods' robustness an encoder identification algorithm was developed and applied based on analysis of inherent parameters of compression. The effectiveness of tampering detection algorithms is tested on a predefined large music database consisting of nearly one million of compressed audio files. The influence of compression algorithms' parameters on the classification performance is discussed, based on the results of the current study. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Impact of Various Compression Ratio on the Compression Ignition Engine with Diesel and Jatropha Biodiesel

    Science.gov (United States)

    Sivaganesan, S.; Chandrasekaran, M.; Ruban, M.

    2017-03-01

    The present experimental investigation evaluates the effects of using blends of diesel fuel with 20% concentration of Methyl Ester of Jatropha biodiesel blended with various compression ratio. Both the diesel and biodiesel fuel blend was injected at 23º BTDC to the combustion chamber. The experiment was carried out with three different compression ratio. Biodiesel was extracted from Jatropha oil, 20% (B20) concentration is found to be best blend ratio from the earlier experimental study. The engine was maintained at various compression ratio i.e., 17.5, 16.5 and 15.5 respectively. The main objective is to obtain minimum specific fuel consumption, better efficiency and lesser Emission with different compression ratio. The results concluded that full load show an increase in efficiency when compared with diesel, highest efficiency is obtained with B20MEOJBA with compression ratio 17.5. It is noted that there is an increase in thermal efficiency as the blend ratio increases. Biodiesel blend has performance closer to diesel, but emission is reduced in all blends of B20MEOJBA compared to diesel. Thus this work focuses on the best compression ratio and suitability of biodiesel blends in diesel engine as an alternate fuel.

  9. The relationship between compression force, image quality and ...

    African Journals Online (AJOL)

    Theoretically, an increase in breast compression gives a reduction in thickness without changing the density, resulting in improved image quality and reduced radiation dose. Aim. This study investigates the relationship between compression force, phantom thickness, image quality and radiation dose. The existence of a ...

  10. Compressed Sensing Of Complex Sinusoids Off The Grid

    Science.gov (United States)

    Ping, Cheng; Liu, Shi; Jiaqun, Zhao

    2015-07-01

    To solve off-grid problem in compressed sensing, a new reconstruction algorithm for complex sinusoids is proposed. The compressed sensing reconstruction problem is transformed into a joint optimized problem. Based on coordinate descent approach and linear estimator, a new iteration algorithm is proposed. The results of experiments verify the effectiveness of the proposed method.

  11. Compression of magnetized target in the magneto-inertial fusion

    Science.gov (United States)

    Kuzenov, V. V.

    2017-12-01

    This paper presents a mathematical model, numerical method and results of the computer analysis of the compression process and the energy transfer in the target plasma, used in magneto-inertial fusion. The computer simulation of the compression process of magnetized cylindrical target by high-power laser pulse is presented.

  12. Revisiting the Fundamentals and Capabilities of the Stack Compression Test

    DEFF Research Database (Denmark)

    Alves, L.M.; Nielsen, Chris Valentin; Martin, P.A.F.

    2011-01-01

    performance by comparing the flow curves obtained from its utilisation with those determined by means of compressive testing carried out on solid cylinder specimens of the same material. Results show that mechanical testing of materials by means of the stack compression test is capable of meeting...... the increasing demand of accurate and reliable flow curves for sheet metals....

  13. Effects of Screening on the Thermal Resistivity And Compressibility ...

    African Journals Online (AJOL)

    Models for computing thermal resistivity, compressibility ratio, and screening parameter of metals was developed and used to study the effects of screening on the thermal resistivity and compressibility ratio of metals. The results obtained revealed that the thermal resistivity of metals increases with an increase in the electron ...

  14. Model-based fitting of compression settings using narrowband stimuli

    DEFF Research Database (Denmark)

    Kowalewski, Borys; Fereczkowski, Michal; MacDonald, Ewen

    Most state-of-the-art hearing aids apply multi-channel dynamic-range compression (DRC). Studies using speech intelligibility as an outcome measure have shown mixed results in terms of the benefits of compression over linear amplification (e.g. Davies-Venn et al. 2009; Goedegebure et al. 2001, 200...

  15. Compressive Feedback Control Design for Spatially Distributed Systems

    Science.gov (United States)

    2017-01-03

    AFRL-AFOSR-VA-TR-2017-0004 Compressive Feedback Control Design for Spatially Distributed Systems Nader Motee LEHIGH UNIVERSITY 526 BRODHEAD AVE...0158 Compressive Feedback Control Design for Spatially Distributed Systems Program Manager: Dr. Frederick A. Leve Principle Investigator: Nader Motee...Feedback Control Design for Spatially Distributed Systems Summary of Accomplishments and Research Results 1 Systemic Performance and Robustness

  16. John Strong (1941 - 2006)

    CERN Multimedia

    Wickens, F

    Our friend and colleague John Strong was cruelly taken from us by a brain tumour on Monday 31st July, a few days before his 65th birthday John started his career working with a group from Westfield College, under the leadership of Ted Bellamy. He obtained his PhD and spent the early part of his career on experiments at Rutherford Appleton Laboratory (RAL), but after the early 1970s his research was focussed on experiments in CERN. Over the years he made a number of notable contributions to experiments in CERN: The Omega spectrometer adopted a system John had originally developed for experiments at RAL using vidicon cameras to record the sparks in the spark chambers; He contributed to the success of NA1 and NA7, where he became heavily involved in the electronic trigger systems; He was responsible for the second level trigger system for the ALEPH detector and spent five years leading a team that designed and built the system, which ran for twelve years with only minor interventions. Following ALEPH he tur...

  17. Stirring Strongly Coupled Plasma

    CERN Document Server

    Fadafan, Kazem Bitaghsir; Rajagopal, Krishna; Wiedemann, Urs Achim

    2009-01-01

    We determine the energy it takes to move a test quark along a circle of radius L with angular frequency w through the strongly coupled plasma of N=4 supersymmetric Yang-Mills (SYM) theory. We find that for most values of L and w the energy deposited by stirring the plasma in this way is governed either by the drag force acting on a test quark moving through the plasma in a straight line with speed v=Lw or by the energy radiated by a quark in circular motion in the absence of any plasma, whichever is larger. There is a continuous crossover from the drag-dominated regime to the radiation-dominated regime. In the crossover regime we find evidence for significant destructive interference between energy loss due to drag and that due to radiation as if in vacuum. The rotating quark thus serves as a model system in which the relative strength of, and interplay between, two different mechanisms of parton energy loss is accessible via a controlled classical gravity calculation. We close by speculating on the implicati...

  18. Strong-interaction nonuniversality

    International Nuclear Information System (INIS)

    Volkas, R.R.; Foot, R.; He, X.; Joshi, G.C.

    1989-01-01

    The universal QCD color theory is extended to an SU(3) 1 direct product SU(3) 2 direct product SU(3) 3 gauge theory, where quarks of the ith generation transform as triplets under SU(3)/sub i/ and singlets under the other two factors. The usual color group is then identified with the diagonal subgroup, which remains exact after symmetry breaking. The gauge bosons associated with the 16 broken generators then form two massive octets under ordinary color. The interactions between quarks and these heavy gluonlike particles are explicitly nonuniversal and thus an exploration of their physical implications allows us to shed light on the fundamental issue of strong-interaction universality. Nonuniversality and weak flavor mixing are shown to generate heavy-gluon-induced flavor-changing neutral currents. The phenomenology of these processes is studied, as they provide the major experimental constraint on the extended theory. Three symmetry-breaking scenarios are presented. The first has color breaking occurring at the weak scale, while the second and third divorce the two scales. The third model has the interesting feature of radiatively induced off-diagonal Kobayashi-Maskawa matrix elements

  19. Influence of Compacting Rate on the Properties of Compressed Earth Blocks

    Directory of Open Access Journals (Sweden)

    Humphrey Danso

    2016-01-01

    Full Text Available Compaction of blocks contributes significantly to the strength properties of compressed earth blocks. This paper investigates the influence of compacting rates on the properties of compressed earth blocks. Experiments were conducted to determine the density, compressive strength, splitting tensile strength, and erosion properties of compressed earth blocks produced with different rates of compacting speed. The study concludes that although the low rate of compaction achieved slightly better performance characteristics, there is no statistically significant difference between the soil blocks produced with low compacting rate and high compacting rate. The study demonstrates that there is not much influence on the properties of compressed earth blocks produced with low and high compacting rates. It was further found that there are strong linear correlations between the compressive strength test and density, and density and the erosion. However, a weak linear correlation was found between tensile strength and compressive strength, and tensile strength and density.

  20. Working Characteristics of Variable Intake Valve in Compressed Air Engine

    Directory of Open Access Journals (Sweden)

    Qihui Yu

    2014-01-01

    Full Text Available A new camless compressed air engine is proposed, which can make the compressed air energy reasonably distributed. Through analysis of the camless compressed air engine, a mathematical model of the working processes was set up. Using the software MATLAB/Simulink for simulation, the pressure, temperature, and air mass of the cylinder were obtained. In order to verify the accuracy of the mathematical model, the experiments were conducted. Moreover, performance analysis was introduced to design compressed air engine. Results show that, firstly, the simulation results have good consistency with the experimental results. Secondly, under different intake pressures, the highest output power is obtained when the crank speed reaches 500 rpm, which also provides the maximum output torque. Finally, higher energy utilization efficiency can be obtained at the lower speed, intake pressure, and valve duration angle. This research can refer to the design of the camless valve of compressed air engine.

  1. Working characteristics of variable intake valve in compressed air engine.

    Science.gov (United States)

    Yu, Qihui; Shi, Yan; Cai, Maolin

    2014-01-01

    A new camless compressed air engine is proposed, which can make the compressed air energy reasonably distributed. Through analysis of the camless compressed air engine, a mathematical model of the working processes was set up. Using the software MATLAB/Simulink for simulation, the pressure, temperature, and air mass of the cylinder were obtained. In order to verify the accuracy of the mathematical model, the experiments were conducted. Moreover, performance analysis was introduced to design compressed air engine. Results show that, firstly, the simulation results have good consistency with the experimental results. Secondly, under different intake pressures, the highest output power is obtained when the crank speed reaches 500 rpm, which also provides the maximum output torque. Finally, higher energy utilization efficiency can be obtained at the lower speed, intake pressure, and valve duration angle. This research can refer to the design of the camless valve of compressed air engine.

  2. Liquid metals. Coexistence line, critical parameters, compressibility

    International Nuclear Information System (INIS)

    Filippov, L.P.

    1986-01-01

    Formulae to calculate four characteristic parameters of liquid metals (density, compressibility, critical temperature and individual parameter) according to four initial data are obtained: two values of vapor density and two values of vapor pressure. Comparison between experimental and calculation results are presented for liquid Cs, Na, Li, K, Rb

  3. A high compression crystal growth system

    International Nuclear Information System (INIS)

    Nieman, H.F.; Walton, A.A.; Powell, B.M.; Dolling, G.

    1980-01-01

    This report describes the construction and operating procedure for a high compression crystal growth system, capable of growing single crystals from the fluid phase over the temperature range of 4.2 K to 300 K, at pressures up to 900 MPa. Some experimental results obtained with the system are given for solid β-nitrogen. (auth)

  4. OPTIMISATION OF COMPRESSIVE STRENGTH OF PERIWINKLE ...

    African Journals Online (AJOL)

    In this paper, a regression model is developed to predict and optimise the compressive strength of periwinkle shell aggregate concrete using Scheffe's regression theory. The results obtained from the derived regression model agreed favourably with the experimental data. The model was tested for adequacy using a student ...

  5. Compression, Mechanical and Release Properties of Chloroquine ...

    African Journals Online (AJOL)

    Results: Tablet formulations containing trifoliate yam starch exhibited faster onset and higher amount of plastic deformation during compression than those containing corn starch. The crushing strength, disintegration and dissolution times of the tablets increased with binder concentration while friability values decreased.

  6. Adiabatic compression and radiative compression of magnetic fields

    International Nuclear Information System (INIS)

    Woods, C.H.

    1980-01-01

    Flux is conserved during mechanical compression of magnetic fields for both nonrelativistic and relativistic compressors. However, the relativistic compressor generates radiation, which can carry up to twice the energy content of the magnetic field compressed adiabatically. The radiation may be either confined or allowed to escape

  7. Parallel Tensor Compression for Large-Scale Scientific Data.

    Energy Technology Data Exchange (ETDEWEB)

    Kolda, Tamara G. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Ballard, Grey [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Austin, Woody Nathan [Univ. of Texas, Austin, TX (United States)

    2015-10-01

    As parallel computing trends towards the exascale, scientific data produced by high-fidelity simulations are growing increasingly massive. For instance, a simulation on a three-dimensional spatial grid with 512 points per dimension that tracks 64 variables per grid point for 128 time steps yields 8 TB of data. By viewing the data as a dense five way tensor, we can compute a Tucker decomposition to find inherent low-dimensional multilinear structure, achieving compression ratios of up to 10000 on real-world data sets with negligible loss in accuracy. So that we can operate on such massive data, we present the first-ever distributed memory parallel implementation for the Tucker decomposition, whose key computations correspond to parallel linear algebra operations, albeit with nonstandard data layouts. Our approach specifies a data distribution for tensors that avoids any tensor data redistribution, either locally or in parallel. We provide accompanying analysis of the computation and communication costs of the algorithms. To demonstrate the compression and accuracy of the method, we apply our approach to real-world data sets from combustion science simulations. We also provide detailed performance results, including parallel performance in both weak and strong scaling experiments.

  8. Advanced and standardized evaluation of neurovascular compression syndromes

    Science.gov (United States)

    Hastreiter, Peter; Vega Higuera, Fernando; Tomandl, Bernd; Fahlbusch, Rudolf; Naraghi, Ramin

    2004-05-01

    Caused by a contact between vascular structures and the root entry or exit zone of cranial nerves neurovascular compression syndromes are combined with different neurological diseases (trigeminal neurolagia, hemifacial spasm, vertigo, glossopharyngeal neuralgia) and show a relation with essential arterial hypertension. As presented previously, the semi-automatic segmentation and 3D visualization of strongly T2 weighted MR volumes has proven to be an effective strategy for a better spatial understanding prior to operative microvascular decompression. After explicit segmentation of coarse structures, the tiny target nerves and vessels contained in the area of cerebrospinal fluid are segmented implicitly using direct volume rendering. However, based on this strategy the delineation of vessels in the vicinity of the brainstem and those at the border of the segmented CSF subvolume are critical. Therefore, we suggest registration with MR angiography and introduce consecutive fusion after semi-automatic labeling of the vascular information. Additionally, we present an approach of automatic 3D visualization and video generation based on predefined flight paths. Thereby, a standardized evaluation of the fused image data is supported and the visualization results are optimally prepared for intraoperative application. Overall, our new strategy contributes to a significantly improved 3D representation and evaluation of vascular compression syndromes. Its value for diagnosis and surgery is demonstrated with various clinical examples.

  9. Mental simulation of routes during navigation involves adaptive temporal compression.

    Science.gov (United States)

    Arnold, Aiden E G F; Iaria, Giuseppe; Ekstrom, Arne D

    2016-12-01

    Mental simulation is a hallmark feature of human cognition, allowing features from memories to be flexibly used during prospection. While past studies demonstrate the preservation of real-world features such as size and distance during mental simulation, their temporal dynamics remains unknown. Here, we compare mental simulations to navigation of routes in a large-scale spatial environment to test the hypothesis that such simulations are temporally compressed in an adaptive manner. Our results show that simulations occurred at 2.39× the speed it took to navigate a route, increasing in compression (3.57×) for slower movement speeds. Participant self-reports of vividness and spatial coherence of simulations also correlated strongly with simulation duration, providing an important link between subjective experiences of simulated events and how spatial representations are combined during prospection. These findings suggest that simulation of spatial events involve adaptive temporal mechanisms, mediated partly by the fidelity of memories used to generate the simulation. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Tokamak heating by neutral beams and adiabatic compression

    International Nuclear Information System (INIS)

    Furth, H.P.

    1973-08-01

    ''Realistic'' models of tokamak energy confinement strongly favor reactor operation at the maximum MHD-stable β-value, in order to maximize plasma density. Ohmic heating is unsuitable for this purpose. Neutral-beam heating plus compression is well suited; however, very large requirements on device size and injection power seem likely for a DT ignition experiment using a Maxwellian plasma. Results of the ATC experiment are reviewed, including Ohmic heating, neutral-beam heating, and production of two-energy-component plasmas (energetic deuteron population in deuterium ''target plasma''). A modest extrapolation of present ATC parameters could give zero-power conditions in a DT experiment of the two-energy-component type. (U.S.)

  11. Compressive strength of continuous fiber unidirectional composites

    Science.gov (United States)

    Thompson, Ronald H.

    Dow and Rosen's work in 1965 formed an intellectual framework for compressive strength of unidirectional composites. Compressive strength was explained in terms of micro-buckling, in which filaments are beams on an elastic foundation. They made simplifying assumptions, with a two dimensional idealization and linearized material properties. This study builds on their model, recognizing that the shear mode of instability drives unidirectional compressive strength. As a necessary corollary, the predictive methods developed in this study emphasize correct representation of composite shear stiffness. Non-linear effects related to matrix material properties, fiber misalignment, three dimensional representation, and thermal prestrains are taken into account. Four work streams comprise this study: first, development of a closed form analytical model; second, empirical methods development and model validation; third, creation and validation of a unit cell finite element model; and fourth, a patent application that leverages knowledge gained from the first three work streams. The analytical model characterizes the non-linearity of the matrix both with respect to shear and compressive loading. This improvement on existing analyses clearly shows why fiber modulus affects composite shear instability. Accounting for fiber misalignment in the model and experimental characterization of the fiber misalignment continuum are important contributions of this study. A simple method of compressive strength measurement of a small diameter monofilament glass-resin composite is developed. Sample definition and preparation are original, and necessary technologies are easily assessable to other researchers in this field. This study shows that glass fiber composites have the potential for high compressive strength. This potential is reached with excellent fiber alignment and suitable matrix characteristics, and results are consistent with model predictions. The unit cell three dimensional

  12. Numerical simulation of compressible two-phase flow using a diffuse interface method

    International Nuclear Information System (INIS)

    Ansari, M.R.; Daramizadeh, A.

    2013-01-01

    Highlights: ► Compressible two-phase gas–gas and gas–liquid flows simulation are conducted. ► Interface conditions contain shock wave and cavitations. ► A high-resolution diffuse interface method is investigated. ► The numerical results exhibit very good agreement with experimental results. -- Abstract: In this article, a high-resolution diffuse interface method is investigated for simulation of compressible two-phase gas–gas and gas–liquid flows, both in the presence of shock wave and in flows with strong rarefaction waves similar to cavitations. A Godunov method and HLLC Riemann solver is used for discretization of the Kapila five-equation model and a modified Schmidt equation of state (EOS) is used to simulate the cavitation regions. This method is applied successfully to some one- and two-dimensional compressible two-phase flows with interface conditions that contain shock wave and cavitations. The numerical results obtained in this attempt exhibit very good agreement with experimental results, as well as previous numerical results presented by other researchers based on other numerical methods. In particular, the algorithm can capture the complex flow features of transient shocks, such as the material discontinuities and interfacial instabilities, without any oscillation and additional diffusion. Numerical examples show that the results of the method presented here compare well with other sophisticated modeling methods like adaptive mesh refinement (AMR) and local mesh refinement (LMR) for one- and two-dimensional problems

  13. TPC data compression

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Jens; Frankenfeld, Ulrich; Lindenstruth, Volker; Plamper, Patrick; Roehrich, Dieter; Schaefer, Erich; W. Schulz, Markus; M. Steinbeck, Timm; Stock, Reinhard; Sulimma, Kolja; Vestboe, Anders; Wiebalck, Arne E-mail: wiebalck@kip.uni-heidelberg.de

    2002-08-21

    In the collisions of ultra-relativistic heavy ions in fixed-target and collider experiments, multiplicities of several ten thousand charged particles are generated. The main devices for tracking and particle identification are large-volume tracking detectors (TPCs) producing raw event sizes in excess of 100 Mbytes per event. With increasing data rates, storage becomes the main limiting factor in such experiments and, therefore, it is essential to represent the data in a way that is as concise as possible. In this paper, we present several compression schemes, such as entropy encoding, modified vector quantization, and data modeling techniques applied on real data from the CERN SPS experiment NA49 and on simulated data from the future CERN LHC experiment ALICE.

  14. Waves and compressible flow

    CERN Document Server

    Ockendon, Hilary

    2016-01-01

    Now in its second edition, this book continues to give readers a broad mathematical basis for modelling and understanding the wide range of wave phenomena encountered in modern applications.  New and expanded material includes topics such as elastoplastic waves and waves in plasmas, as well as new exercises.  Comprehensive collections of models are used to illustrate the underpinning mathematical methodologies, which include the basic ideas of the relevant partial differential equations, characteristics, ray theory, asymptotic analysis, dispersion, shock waves, and weak solutions. Although the main focus is on compressible fluid flow, the authors show how intimately gasdynamic waves are related to wave phenomena in many other areas of physical science.   Special emphasis is placed on the development of physical intuition to supplement and reinforce analytical thinking. Each chapter includes a complete set of carefully prepared exercises, making this a suitable textbook for students in applied mathematics, ...

  15. Mechanical properties of Concrete with SAP. Part I: Development of compressive strength

    DEFF Research Database (Denmark)

    Hasholt, Marianne Tange; Jespersen, Morten H. Seneka; Jensen, Ole Mejlhede

    2010-01-01

    compressive strength. It shows that results agree well with a model based on the following: 1. Concrete compressive strength is proportional to compressive strength of the paste phase 2. Paste strength depends on gel space ratio, as suggested by Powers 3. The influence of air voids created by SAP...... on compressive strength can be accounted for in the same way as when taking the air content into account in Bolomeys formula. The implication of the model is that at low w/c ratios (w/c compressive strength at later ages (from 3 days after casting and onwards...... the compressive strength....

  16. Incompressible limit of the degenerate quantum compressible Navier-Stokes equations with general initial data

    Science.gov (United States)

    Kwon, Young-Sam; Li, Fucai

    2018-03-01

    In this paper we study the incompressible limit of the degenerate quantum compressible Navier-Stokes equations in a periodic domain T3 and the whole space R3 with general initial data. In the periodic case, by applying the refined relative entropy method and carrying out the detailed analysis on the oscillations of velocity, we prove rigorously that the gradient part of the weak solutions (velocity) of the degenerate quantum compressible Navier-Stokes equations converge to the strong solution of the incompressible Navier-Stokes equations. Our results improve considerably the ones obtained by Yang, Ju and Yang [25] where only the well-prepared initial data case is considered. While for the whole space case, thanks to the Strichartz's estimates of linear wave equations, we can obtain the convergence of the weak solutions of the degenerate quantum compressible Navier-Stokes equations to the strong solution of the incompressible Navier-Stokes/Euler equations with a linear damping term. Moreover, the convergence rates are also given.

  17. Immobilization induced molecular compression of ionic liquid in ordered mesoporous matrix

    Science.gov (United States)

    Tripathi, Alok Kumar; Singh, Rajendra Kumar

    2018-02-01

    In this work, ionic liquid (IL) 1-ethyl-3-methylimidazolium bis(fluorosulfonyl)imide ([EMIM][FSI]) has been immobilized into ordered mesoporous silica MCM-41 by a physical imbibition process. Transmission electron microscopy confirms the filling of mesopores of MCM-41. The effect of IL content in MCM-41 was probed in terms of thermal stability, chemical interactions, and dielectric properties. N2-sorption results indicate the compression of the IL in the nanopores of MCM-41, which contributes to an increase of the melting point probed by differential scanning calorimetry. The quantum chemical calculations confirmed that the ion–ion interaction in ion-pairs of IL were preferred over the hydrogen bonding interaction in the presence of SiO2 molecules, and these interactions probably compress the molecular size in the nanopores of MCM-41. Strong interactions between IL and porous MCM-41 were suggested as the mechanism of this immobilization, which was characterized by FTIR and dielectric spectroscopy.

  18. Primary User Localization Algorithm Based on Compressive Sensing in Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    Fang Ye

    2016-04-01

    Full Text Available In order to locate source signal more accurately in authorized frequency bands, a novel primary user localization algorithm based on compressive sensing (PU-CSL in cognitive radio networks (CRNs is proposed in this paper. In comparison to existing centroid locating algorithms, PU-CSL shows higher locating accuracy for integrally exploring correlation between source signal and secondary users (SUs. Energy detection is first adopted for collecting the energy fingerprint of source signal at each SU, then degree of correlation between source signal and SUs is reconstructed based on compressive sensing (CS, which determines weights of centroid coordinates. A weighted centroid scheme is finally utilized to estimate source position. Simulation results show that PU-CSL has smaller maximum error of positioning and root-mean-square error. Moreover, the proposed PU-CSL algorithm possess excellent location accuracy and strong anti-noise performance.

  19. An FPGA Based Implementation of a CFAR Processor Applied to a Pulse-Compression Radar System

    Directory of Open Access Journals (Sweden)

    S.Simić

    2014-04-01

    Full Text Available A hardware architecture that implements a CFAR processor including six variants of the CFAR algorithm based on linear and nonlinear operations for radar applications is presented. Since some implemented CFAR algorithms require sorting the input samples, the two sorting solutions are investigated. The first one is iterative, and it is suitable when incoming data clock is several times less than sorting clock. The second sorter is very fast by exploiting a high degree of parallelism. The architecture is on-line reconfigurable both in terms of CFAR method and in terms of the number of reference and guard cells. The architecture was developed for coherent radar with pulse compression. Besides dealing with surface clutter and multiple target situations, such radar detector is often faced with high side-lobes at the compression filter output when strong target presents in his sight. The results of implementing the architecture on a Field Programmable Gate Array (FPGA are presented and discussed.

  20. Estimating Compressive Strength of High Performance Concrete with Gaussian Process Regression Model

    Directory of Open Access Journals (Sweden)

    Nhat-Duc Hoang

    2016-01-01

    Full Text Available This research carries out a comparative study to investigate a machine learning solution that employs the Gaussian Process Regression (GPR for modeling compressive strength of high-performance concrete (HPC. This machine learning approach is utilized to establish the nonlinear functional mapping between the compressive strength and HPC ingredients. To train and verify the aforementioned prediction model, a data set containing 239 HPC experimental tests, recorded from an overpass construction project in Danang City (Vietnam, has been collected for this study. Based on experimental outcomes, prediction results of the GPR model are superior to those of the Least Squares Support Vector Machine and the Artificial Neural Network. Furthermore, GPR model is strongly recommended for estimating HPC strength because this method demonstrates good learning performance and can inherently express prediction outputs coupled with prediction intervals.

  1. Fast-electron transport in cylindrically laser-compressed matter

    Science.gov (United States)

    Perez, F.; Koenig, M.; Batani, D.; Baton, S. D.; Beg, F. N.; Benedetti, C.; Brambrink, E.; Chawla, S.; Dorchies, F.; Fourment, C.; Galimberti, M.; Gizzi, L. A.; Heathcote, R.; Higginson, D. P.; Hulin, S.; Jafer, R.; Koester, P.; Labate, L.; Lancaster, K.; Mac Kinnon, A. J.; McPhee, A. G.; Nazarov, W.; Nicolai, P.; Pasley, J.; Ravasio, A.; Richetta, M.; Santos, J. J.; Sgattoni, A.; Spindloe, C.; Vauzour, B.; Volpe, L.

    2009-12-01

    Experimental and theoretical results of relativistic electron transport in cylindrically compressed matter are presented. This experiment, which is a part of the HiPER roadmap, was achieved on the VULCAN laser facility (UK) using four long pulses beams (~4 × 50 J, 1 ns, at 0.53 µm) to compress a hollow plastic cylinder filled with plastic foam of three different densities (0.1, 0.3 and 1 g cm-3). 2D simulations predict a density of 2-5 g cm-3 and a plasma temperature up to 100 eV at maximum compression. A short pulse (10 ps, 160 J) beam generated fast electrons that propagate through the compressed matter by irradiating a nickel foil at an intensity of 5 × 1018 W cm-2. X-ray spectrometer and imagers were implemented in order to estimate the compressed plasma conditions and to infer the hot electron characteristics. Results are discussed and compared with simulations.

  2. Correlation and image compression for limited-bandwidth CCD.

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Douglas G.

    2005-07-01

    As radars move to Unmanned Aerial Vehicles with limited-bandwidth data downlinks, the amount of data stored and transmitted with each image becomes more significant. This document gives the results of a study to determine the effect of lossy compression in the image magnitude and phase on Coherent Change Detection (CCD). We examine 44 lossy compression types, plus lossless zlib compression, and test each compression method with over 600 CCD image pairs. We also derive theoretical predictions for the correlation for most of these compression schemes, which compare favorably with the experimental results. We recommend image transmission formats for limited-bandwidth programs having various requirements for CCD, including programs which cannot allow performance degradation and those which have stricter bandwidth requirements at the expense of CCD performance.

  3. A multiphase compressible model for the simulation of multiphase flows

    International Nuclear Information System (INIS)

    Caltagirone, J.P.; Vincent, St.; Caruyer, C.

    2011-01-01

    A compressible model able to manage incompressible two-phase flows as well as compressible motions is proposed. After a presentation of the multiphase compressible concept, the new model and related numerical methods are detailed on fixed structured grids. The presented model is a 1-fluid model with a reformulated mass conservation equation which takes into account the effects of compressibility. The coupling between pressure and flow velocity is ensured by introducing mass conservation terms in the momentum and energy equations. The numerical model is then validated with four test cases involving the compression of an air bubble by water, the liquid injection in a closed cavity filled with air, a bubble subjected to an ultrasound field and finally the oscillations of a deformed air bubble in melted steel. The numerical results are compared with analytical results and convergence orders in space are provided. (authors)

  4. Origin of the low compressibility in hard nitride spinels

    DEFF Research Database (Denmark)

    Mori-Sánchez, P.; Marqués, M.; Beltrán, A.

    2003-01-01

    A microscopic investigation of first-principles electron densities of gamma-A(3)N(4) (A:C,Si,Ge) spinels reveals a clear relationship between the compressibility and the chemical bonding of these materials. Three striking findings emanate from this analysis: (i) the chemical graph is governed...... by a network of highly directional strong bonds with covalent character in gamma-C3N4 and different degrees of ionic polarization in gamma-Si3N4 and gamma-Ge3N4, (ii) nitrogen is the lowest compressible atom controlling the trend in the bulk modulus of the solids, and (iii) the group-IV counterions show strong...... site dependent compressibilities enhancing the difficulty in the synthesis of the spinel phases of these nitrides....

  5. Oil-free centrifugal hydrogen compression technology demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Heshmat, Hooshang [Mohawk Innovative Technology Inc., Albany, NY (United States)

    2014-05-31

    performance testing of a single stage with helium similitude gas at full speed in accordance with ASME PTC-10. The experimental results indicated that aerodynamic performance, with respect to compressor discharge pressure, flow, power and efficiency exceeded theoretical prediction. Dynamic testing of a simulated multistage centrifugal compressor was also completed under a parallel program to validate the integrity and viability of the system concept. The results give strong confidence in the feasibility of the multi-stage design for use in hydrogen gas transportation and delivery from production locations to point of use.

  6. Tight bounds for top tree compression

    DEFF Research Database (Denmark)

    Bille, Philip; Fernstrøm, Finn; Gørtz, Inge Li

    2017-01-01

    We consider compressing labeled, ordered and rooted trees using DAG compression and top tree compression. We show that there exists a family of trees such that the size of the DAG compression is always a logarithmic factor smaller than the size of the top tree compression (even for an alphabet...

  7. Compressed Baryonic Matter of Astrophysics

    OpenAIRE

    Guo, Yanjun; Xu, Renxin

    2013-01-01

    Baryonic matter in the core of a massive and evolved star is compressed significantly to form a supra-nuclear object, and compressed baryonic matter (CBM) is then produced after supernova. The state of cold matter at a few nuclear density is pedagogically reviewed, with significant attention paid to a possible quark-cluster state conjectured from an astrophysical point of view.

  8. Generalized massive optimal data compression

    Science.gov (United States)

    Alsing, Justin; Wandelt, Benjamin

    2018-02-01

    Data compression has become one of the cornerstones of modern astronomical data analysis, with the vast majority of analyses compressing large raw datasets down to a manageable number of informative summaries. In this paper we provide a general procedure for optimally compressing N data down to n summary statistics, where n is equal to the number of parameters of interest. We show that compression to the score function - the gradient of the log-likelihood with respect to the parameters - yields n compressed statistics that are optimal in the sense that they preserve the Fisher information content of the data. Our method generalizes earlier work on linear Karhunen-Loéve compression for Gaussian data whilst recovering both lossless linear compression and quadratic estimation as special cases when they are optimal. We give a unified treatment that also includes the general non-Gaussian case as long as mild regularity conditions are satisfied, producing optimal non-linear summary statistics when appropriate. As a worked example, we derive explicitly the n optimal compressed statistics for Gaussian data in the general case where both the mean and covariance depend on the parameters.

  9. Compressibility effect in vortex identification

    Czech Academy of Sciences Publication Activity Database

    Kolář, Václav

    2009-01-01

    Roč. 47, č. 2 (2009), s. 473-475 ISSN 0001-1452 R&D Projects: GA AV ČR IAA200600801 Institutional research plan: CEZ:AV0Z20600510 Keywords : vortex * vortex identification * compressible flows * compressibility effect Subject RIV: BK - Fluid Dynamics Impact factor: 0.990, year: 2009

  10. Compressed sensing for body MRI.

    Science.gov (United States)

    Feng, Li; Benkert, Thomas; Block, Kai Tobias; Sodickson, Daniel K; Otazo, Ricardo; Chandarana, Hersh

    2017-04-01

    The introduction of compressed sensing for increasing imaging speed in magnetic resonance imaging (MRI) has raised significant interest among researchers and clinicians, and has initiated a large body of research across multiple clinical applications over the last decade. Compressed sensing aims to reconstruct unaliased images from fewer measurements than are traditionally required in MRI by exploiting image compressibility or sparsity. Moreover, appropriate combinations of compressed sensing with previously introduced fast imaging approaches, such as parallel imaging, have demonstrated further improved performance. The advent of compressed sensing marks the prelude to a new era of rapid MRI, where the focus of data acquisition has changed from sampling based on the nominal number of voxels and/or frames to sampling based on the desired information content. This article presents a brief overview of the application of compressed sensing techniques in body MRI, where imaging speed is crucial due to the presence of respiratory motion along with stringent constraints on spatial and temporal resolution. The first section provides an overview of the basic compressed sensing methodology, including the notion of sparsity, incoherence, and nonlinear reconstruction. The second section reviews state-of-the-art compressed sensing techniques that have been demonstrated for various clinical body MRI applications. In the final section, the article discusses current challenges and future opportunities. 5 J. Magn. Reson. Imaging 2017;45:966-987. © 2016 International Society for Magnetic Resonance in Medicine.

  11. Compressive Sensing in Communication Systems

    DEFF Research Database (Denmark)

    Fyhn, Karsten

    2013-01-01

    . The need for cheaper, smarter and more energy efficient wireless devices is greater now than ever. This thesis addresses this problem and concerns the application of the recently developed sampling theory of compressive sensing in communication systems. Compressive sensing is the merging of signal...... acquisition and compression. It allows for sampling a signal with a rate below the bound dictated by the celebrated Shannon-Nyquist sampling theorem. In some communication systems this necessary minimum sample rate, dictated by the Shannon-Nyquist sampling theorem, is so high it is at the limit of what...... with using compressive sensing in communication systems. The main contribution of this thesis is two-fold: 1) a new compressive sensing hardware structure for spread spectrum signals, which is simpler than the current state-of-the-art, and 2) a range of algorithms for parameter estimation for the class...

  12. Context Modeler for Wavelet Compression of Spectral Hyperspectral Images

    Science.gov (United States)

    Kiely, Aaron; Xie, Hua; Klimesh, matthew; Aranki, Nazeeh

    2010-01-01

    A context-modeling sub-algorithm has been developed as part of an algorithm that effects three-dimensional (3D) wavelet-based compression of hyperspectral image data. The context-modeling subalgorithm, hereafter denoted the context modeler, provides estimates of probability distributions of wavelet-transformed data being encoded. These estimates are utilized by an entropy coding subalgorithm that is another major component of the compression algorithm. The estimates make it possible to compress the image data more effectively than would otherwise be possible. The following background discussion is prerequisite to a meaningful summary of the context modeler. This discussion is presented relative to ICER-3D, which is the name attached to a particular compression algorithm and the software that implements it. The ICER-3D software is summarized briefly in the preceding article, ICER-3D Hyperspectral Image Compression Software (NPO-43238). Some aspects of this algorithm were previously described, in a slightly more general context than the ICER-3D software, in "Improving 3D Wavelet-Based Compression of Hyperspectral Images" (NPO-41381), NASA Tech Briefs, Vol. 33, No. 3 (March 2009), page 7a. In turn, ICER-3D is a product of generalization of ICER, another previously reported algorithm and computer program that can perform both lossless and lossy wavelet-based compression and decompression of gray-scale-image data. In ICER-3D, hyperspectral image data are decomposed using a 3D discrete wavelet transform (DWT). Following wavelet decomposition, mean values are subtracted from spatial planes of spatially low-pass subbands prior to encoding. The resulting data are converted to sign-magnitude form and compressed. In ICER-3D, compression is progressive, in that compressed information is ordered so that as more of the compressed data stream is received, successive reconstructions of the hyperspectral image data are of successively higher overall fidelity.

  13. Compressive confocal microscopy: 3D reconstruction algorithms

    Science.gov (United States)

    Ye, P.; Paredes, J. L.; Wu, Y.; Chen, C.; Arce, G. R.; Prather, D. W.

    2009-02-01

    In this paper, a new approach for Confocal Microscopy (CM) based on the framework of compressive sensing is developed. In the proposed approach, a point illumination and a random set of pinholes are used to eliminate out-of-focus information at the detector. Furthermore, a Digital Micromirror Device (DMD) is used to efficiently scan the 2D or 3D specimen but, unlike the conventional CM that uses CCD detectors, the measured data in the proposed compressive confocal microscopy (CCM) emerge from random sets of pinhole illuminated pixels in the specimen that are linearly combined (projected) and measured by a single photon detector. Compared to conventional CM or programmable array microscopy (PAM), the number of measurements needed for nearly perfect reconstruction in CCM is significantly reduced. Our experimental results are based on a testbed that uses a Texas Instruments DMD (an array of 1024×768 13.68×13.68 μm2 mirrors) for computing the linear projections of illuminated pixels and a single photon detector is used to obtain the compressive sensing measurement. The position of each element in the DMD is defined by the compressed sensing measurement matrices. Threedimensional image reconstruction algorithms are developed that exploit the inter-slice spatial image correlation as well as the correlation between different 2D slices. A comprehensive performance comparison between several binary projection patterns is shown. Experimental and simulation results are provided to illustrate the features of the proposed systems.

  14. Binary rf pulse compression experiment at SLAC

    International Nuclear Information System (INIS)

    Lavine, T.L.; Spalek, G.; Farkas, Z.D.; Menegat, A.; Miller, R.H.; Nantista, C.; Wilson, P.B.

    1990-06-01

    Using rf pulse compression it will be possible to boost the 50- to 100-MW output expected from high-power microwave tubes operating in the 10- to 20-GHz frequency range, to the 300- to 1000-MW level required by the next generation of high-gradient linacs for linear for linear colliders. A high-power X-band three-stage binary rf pulse compressor has been implemented and operated at the Stanford Linear Accelerator Center (SLAC). In each of three successive stages, the rf pulse-length is compressed by half, and the peak power is approximately doubled. The experimental results presented here have been obtained at low-power (1-kW) and high-power (15-MW) input levels in initial testing with a TWT and a klystron. Rf pulses initially 770 nsec long have been compressed to 60 nsec. Peak power gains of 1.8 per stage, and 5.5 for three stages, have been measured. This corresponds to a peak power compression efficiency of about 90% per stage, or about 70% for three stages, consistent with the individual component losses. The principle of operation of a binary pulse compressor (BPC) is described in detail elsewhere. We recently have implemented and operated at SLAC a high-power (high-vacuum) three-stage X-band BPC. First results from the high-power three-stage BPC experiment are reported here

  15. Compression force behaviours: An exploration of the beliefs and values influencing the application of breast compression during screening mammography

    International Nuclear Information System (INIS)

    Murphy, Fred; Nightingale, Julie; Hogg, Peter; Robinson, Leslie; Seddon, Doreen; Mackay, Stuart

    2015-01-01

    This research project investigated the compression behaviours of practitioners during screening mammography. The study sought to provide a qualitative understanding of ‘how’ and ‘why’ practitioners apply compression force. With a clear conflict in the existing literature and little scientific evidence base to support the reasoning behind the application of compression force, this research project investigated the application of compression using a phenomenological approach. Following ethical approval, six focus group interviews were conducted at six different breast screening centres in England. A sample of 41 practitioners were interviewed within the focus groups together with six one-to-one interviews of mammography educators or clinical placement co-ordinators. The findings revealed two broad humanistic and technological categories consisting of 10 themes. The themes included client empowerment, white-lies, time for interactions, uncertainty of own practice, culture, power, compression controls, digital technology, dose audit-safety nets, numerical scales. All of these themes were derived from 28 units of significant meaning (USM). The results demonstrate a wide variation in the application of compression force, thus offering a possible explanation for the difference between practitioner compression forces found in quantitative studies. Compression force was applied in many different ways due to individual practitioner experiences and behaviour. Furthermore, the culture and the practice of the units themselves influenced beliefs and attitudes of practitioners in compression force application. The strongest recommendation to emerge from this study was the need for peer observation to enable practitioners to observe and compare their own compression force practice to that of their colleagues. The findings are significant for clinical practice in order to understand how and why compression force is applied

  16. Large N baryons, strong coupling theory, quarks

    International Nuclear Information System (INIS)

    Sakita, B.

    1984-01-01

    It is shown that in QCD the large N limit is the same as the static strong coupling limit. By using the static strong coupling techniques some of the results of large N baryons are derived. The results are consistent with the large N SU(6) static quark model. (author)

  17. Rydberg atoms in strong fields

    International Nuclear Information System (INIS)

    Kleppner, D.; Tsimmerman, M.

    1985-01-01

    Experimental and theoretical achievements in studying Rydberg atoms in external fields are considered. Only static (or quasistatic) fields and ''one-electron'' atoms, i.e. atoms that are well described by one-electron states, are discussed. Mainly behaviour of alkali metal atoms in electric field is considered. The state of theoretical investigations for hydrogen atom in magnetic field is described, but experimental data for atoms of alkali metals are presented as an illustration. Results of the latest experimental and theoretical investigations into the structure of Rydberg atoms in strong fields are presented

  18. Active RF Pulse Compression Using An Electrically Controlled Semiconductor Switch

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Jiquan; Tantawi, Sami; /SLAC

    2007-01-10

    First we review the theory of active pulse compression systems using resonant delay lines. Then we describe the design of an electrically controlled semiconductor active switch. The switch comprises an active window and an overmoded waveguide three-port network. The active window is based on a four-inch silicon wafer which has 960 PIN diodes. These are spatially combined in an overmoded waveguide. We describe the philosophy and design methodology for the three-port network and the active window. We then present the results of using this device to compress 11.4 GHz RF signals with high compression ratios. We show how the system can be used with amplifier like sources, in which one can change the phase of the source by manipulating the input to the source. We also show how the active switch can be used to compress a pulse from an oscillator like sources, which is not possible with passive pulse compression systems.

  19. Lossless compression of hyperspectral images using hybrid context prediction.

    Science.gov (United States)

    Liang, Yuan; Li, Jianping; Guo, Ke

    2012-03-26

    In this letter a new algorithm for lossless compression of hyperspectral images using hybrid context prediction is proposed. Lossless compression algorithms are typically divided into two stages, a decorrelation stage and a coding stage. The decorrelation stage supports both intraband and interband predictions. The intraband (spatial) prediction uses the median prediction model, since the median predictor is fast and efficient. The interband prediction uses hybrid context prediction. The hybrid context prediction is the combination of a linear prediction (LP) and a context prediction. Finally, the residual image of hybrid context prediction is coded by the arithmetic coding. We compare the proposed lossless compression algorithm with some of the existing algorithms for hyperspectral images such as 3D-CALIC, M-CALIC, LUT, LAIS-LUT, LUT-NN, DPCM (C-DPCM), JPEG-LS. The performance of the proposed lossless compression algorithm is evaluated. Simulation results show that our algorithm achieves high compression ratios with low complexity and computational cost.

  20. Variable valve timing in a homogenous charge compression ignition engine

    Science.gov (United States)

    Lawrence, Keith E.; Faletti, James J.; Funke, Steven J.; Maloney, Ronald P.

    2004-08-03

    The present invention relates generally to the field of homogenous charge compression ignition engines, in which fuel is injected when the cylinder piston is relatively close to the bottom dead center position for its compression stroke. The fuel mixes with air in the cylinder during the compression stroke to create a relatively lean homogeneous mixture that preferably ignites when the piston is relatively close to the top dead center position. However, if the ignition event occurs either earlier or later than desired, lowered performance, engine misfire, or even engine damage, can result. The present invention utilizes internal exhaust gas recirculation and/or compression ratio control to control the timing of ignition events and combustion duration in homogeneous charge compression ignition engines. Thus, at least one electro-hydraulic assist actuator is provided that is capable of mechanically engaging at least one cam actuated intake and/or exhaust valve.

  1. Wavelet/scalar quantization compression standard for fingerprint images

    Energy Technology Data Exchange (ETDEWEB)

    Brislawn, C.M.

    1996-06-12

    US Federal Bureau of Investigation (FBI) has recently formulated a national standard for digitization and compression of gray-scale fingerprint images. Fingerprints are scanned at a spatial resolution of 500 dots per inch, with 8 bits of gray-scale resolution. The compression algorithm for the resulting digital images is based on adaptive uniform scalar quantization of a discrete wavelet transform subband decomposition (wavelet/scalar quantization method). The FBI standard produces archival-quality images at compression ratios of around 15 to 1 and will allow the current database of paper fingerprint cards to be replaced by digital imagery. The compression standard specifies a class of potential encoders and a universal decoder with sufficient generality to reconstruct compressed images produced by any compliant encoder, allowing flexibility for future improvements in encoder technology. A compliance testing program is also being implemented to ensure high standards of image quality and interchangeability of data between different implementations.

  2. Plain strain compression tests on Zircaloy-4 specimens

    International Nuclear Information System (INIS)

    Matucha, K.H.

    1984-01-01

    Plane strain compression tests on rectangular specimens of Zircaloy-4 were performed using a special equipment. The specimens were taken from thickwalled tubes, the edges of the test specimens being parallel to the axial, tangential and radial directions of the tubes, respectively. Two different plane strain compression tests were conducted (test I: compression in the radial direction and no plastic flow in the tangential direction; test II: compression in the tangential direction and no plastic flow in the radial direction). These tests were done on specimes of seven tubes with different textures. The textures differ in the distribution of the basal poles and the corresponding orientation parameters while a <11anti 20<-direction was parallel to the axial direction in all cases. A relationship was found between the results of the plane strain compression tests and the distribution of the basal poles. This can be explained on the basis of calculated yield loci using texture data. (orig.)

  3. Compresso: Efficient Compression of Segmentation Data for Connectomics

    KAUST Repository

    Matejek, Brian

    2017-09-03

    Recent advances in segmentation methods for connectomics and biomedical imaging produce very large datasets with labels that assign object classes to image pixels. The resulting label volumes are bigger than the raw image data and need compression for efficient storage and transfer. General-purpose compression methods are less effective because the label data consists of large low-frequency regions with structured boundaries unlike natural image data. We present Compresso, a new compression scheme for label data that outperforms existing approaches by using a sliding window to exploit redundancy across border regions in 2D and 3D. We compare our method to existing compression schemes and provide a detailed evaluation on eleven biomedical and image segmentation datasets. Our method provides a factor of 600–2200x compression for label volumes, with running times suitable for practice.

  4. Image and audio wavelet integration for home security video compression

    Science.gov (United States)

    Cheng, Yu-Shen; Huang, Gen-Dow

    2002-03-01

    We present a novel wavelet compression algorithm for both audio and image with acceptable test by human perception. It is well known that Discrete Wavelet Transform (DWT) provides global multiple resolution decomposition that is the significant feature for the audio and image compressions. Experimental simulations show that the proposed audio and image model can satisfy the current industrial communication requirements in terms of the processing time and the compression fidelity. Development of wavelet-based compression algorithm considers the trade-off for hardware implementations. As a result, this high-performance video codec can develop compact, low power, high-speed, portable, cost-effective, and low-weight video compression for multimedia and home security applications.

  5. Experimental study on compressive strength of sediment brick masonry

    Science.gov (United States)

    Woen, Ean Lee; Malek, Marlinda Abdul; Mohammed, Bashar S.; Chao-Wei, Tang; Tamunif, Muhammad Thaqif

    2018-02-01

    The effects of pre-wetted unit bricks, mortar type and slenderness ratio of prisms on the compressive strength and failure mode of newly developed sediment brick have been evaluated and compared to clay brick and cement-sand bricks. The results show that pre-wetted sediment brick masonry exhibits higher compressive strength of up to 20% compared to the dry sediment masonry. Using cement-lime mortar leads to lower compressive strength compared to cement mortar. However, the sediment brick masonry with the cement lime mortar exhibit higher compressive strength in comparison with cement mortar masonry. More of diagonal shear cracks have been observed in the failure mode of the sediment bricks masonry compared to clay and cement-sand bricks masonry that show mostly vertical cracks and crushing. The sediment unit bricks display compressive strength in between clay and cement-sand bricks.

  6. Mathematical modeling of compression processes in air-driven boosters

    International Nuclear Information System (INIS)

    Li Zeyu; Zhao Yuanyang; Li Liansheng; Shu Pengcheng

    2007-01-01

    The compressed air in normal pressure is used as the source of power of the air-driven booster. The continuous working of air-driven boosters relies on the difference of surface area between driven piston and driving piston, i.e., the different forces acting on the pistons. When the working surface area of the driving piston for providing power is greater than that of the driven piston for compressing gas, the gas in compression chamber will be compressed. On the basis of the first law of thermodynamics, the motion regulation of piston is analyzed and the mathematical model of compression processes is set up. Giving a calculating example, the vary trends of gas pressure and pistons' move in working process of booster have been gotten. The change of parameters at different working conditions is also calculated and compared. And the corresponding results can be referred in the design of air-driven boosters

  7. Algorithms and data structures for grammar-compressed strings

    DEFF Research Database (Denmark)

    Cording, Patrick Hagge

    demanding task. In this thesis we design data structures for accessing and searching compressed data efficiently. Our results can be divided into two categories. In the first category we study problems related to pattern matching. In particular, we present new algorithms for counting and comparing...... substrings, and a new algorithm for finding all occurrences of a pattern in which we may insert gaps. In the other category we deal with accessing and decompressing parts of the compressed string. We show how to quickly access a single character of the compressed string, and present a data structure......Textual databases for e.g. biological or web-data are growing rapidly, and it is often only feasible to store the data in compressed form. However, compressing the data comes at a price. Traditional algorithms for e.g. pattern matching requires all data to be decompressed - a computationally...

  8. Picosecond chirped pulse compression in single-mode fibers

    International Nuclear Information System (INIS)

    Wenhua Cao; Youwei Zhang

    1995-01-01

    In this paper, the nonlinear propagation of picosecond chirped pulses in single mode fibers has been investigated both analytically and numerically. Results show that downchirped pulses can be compressed owing to normal group-velocity dispersion. The compression ratio depends both on the initial peak power and on the initial frequency chirp of the input pulse. While the compression ratio depends both on the initial peak power and on the initial frequency chirp of the input pulse. While the compression ratio increases with the negative frequency chirp, it decreases with the initial peak power of the input pulse. This means that the self-phase modulation induced nonlinear frequency chirp which is linear and positive (up-chirp) over a large central region of the pulse and tends to cancel the initial negative chirp of the pulse. It is also shown that, as the negative chirped pulse compresses temporally, it synchronously experiences a spectral narrowing

  9. Chaos-Based Simultaneous Compression and Encryption for Hadoop.

    Science.gov (United States)

    Usama, Muhammad; Zakaria, Nordin

    2017-01-01

    Data compression and encryption are key components of commonly deployed platforms such as Hadoop. Numerous data compression and encryption tools are presently available on such platforms and the tools are characteristically applied in sequence, i.e., compression followed by encryption or encryption followed by compression. This paper focuses on the open-source Hadoop framework and proposes a data storage method that efficiently couples data compression with encryption. A simultaneous compression and encryption scheme is introduced that addresses an important implementation issue of source coding based on Tent Map and Piece-wise Linear Chaotic Map (PWLM), which is the infinite precision of real numbers that result from their long products. The approach proposed here solves the implementation issue by removing fractional components that are generated by the long products of real numbers. Moreover, it incorporates a stealth key that performs a cyclic shift in PWLM without compromising compression capabilities. In addition, the proposed approach implements a masking pseudorandom keystream that enhances encryption quality. The proposed algorithm demonstrated a congruent fit within the Hadoop framework, providing robust encryption security and compression.

  10. The phase transition of RDX under hydrostatic and ramp compression

    Science.gov (United States)

    Zheng, Xianxu; Zhang, Zhaohui; Zhao, Jun; Zeng, Daipeng; Zeng, Yangyang; Zhang, Xu

    2017-06-01

    The thermodynamic state of explosive was highly dependent on the phase transition structure and phase transition of explosive crystal. However, the phase transition details of explosive have never been characterized sufficiently under different compression conditions. In this study, both the hydrostatic and ramp compression were performed to examine the phase transition of RDX crystal. Based on our experimental results, we confirmed the α- γ phase transition onset around 4 GPa under hydrostatic compression, which agree with the published literature very well. In the ramp compression experiment, a 260 ns ramp compression up to 30 GPa was generated to compress the RDX single crystal along 020 crystal axis, the PDV signal indicated that the phase transition was induced around 2.8 GPa, and the phase transition induction time was about several tens nanoseconds. Our preliminary experiments suggest that the phase transition pressure of RDX have great relation with the compression history, that probably means the phase transition mechanism were quite different between the hydrostatic and ramp compression.

  11. Breast compression in mammography: how much is enough?

    Science.gov (United States)

    Poulos, Ann; McLean, Donald; Rickard, Mary; Heard, Robert

    2003-06-01

    The amount of breast compression that is applied during mammography potentially influences image quality and the discomfort experienced. The aim of this study was to determine the relationship between applied compression force, breast thickness, reported discomfort and image quality. Participants were women attending routine breast screening by mammography at BreastScreen New South Wales Central and Eastern Sydney. During the mammographic procedure, an 'extra' craniocaudal (CC) film was taken at a reduced level of compression ranging from 10 to 30 Newtons. Breast thickness measurements were recorded for both the normal and the extra CC film. Details of discomfort experienced, cup size, menstrual status, existing breast pain and breast problems were also recorded. Radiologists were asked to compare the image quality of the normal and manipulated film. The results indicated that 24% of women did not experience a difference in thickness when the compression was reduced. This is an important new finding because the aim of breast compression is to reduce breast thickness. If breast thickness is not reduced when compression force is applied then discomfort is increased with no benefit in image quality. This has implications for mammographic practice when determining how much breast compression is sufficient. Radiologists found a decrease in contrast resolution within the fatty area of the breast between the normal and the extra CC film, confirming a decrease in image quality due to insufficient applied compression force.

  12. Compression Testing of Textile Composite Materials

    Science.gov (United States)

    Masters, John E.

    1996-01-01

    The applicability of existing test methods, which were developed primarily for laminates made of unidirectional prepreg tape, to textile composites is an area of concern. The issue is whether the values measured for the 2-D and 3-D braided, woven, stitched, and knit materials are accurate representations of the true material response. This report provides a review of efforts to establish a compression test method for textile reinforced composite materials. Experimental data have been gathered from several sources and evaluated to assess the effectiveness of a variety of test methods. The effectiveness of the individual test methods to measure the material's modulus and strength is determined. Data are presented for 2-D triaxial braided, 3-D woven, and stitched graphite/epoxy material. However, the determination of a recommended test method and specimen dimensions is based, primarily, on experimental results obtained by the Boeing Defense and Space Group for 2-D triaxially braided materials. They evaluated seven test methods: NASA Short Block, Modified IITRI, Boeing Open Hole Compression, Zabora Compression, Boeing Compression after Impact, NASA ST-4, and a Sandwich Column Test.

  13. RAW camera DPCM compression performance analysis

    Science.gov (United States)

    Bouman, Katherine; Ramachandra, Vikas; Atanassov, Kalin; Aleksic, Mickey; Goma, Sergio R.

    2011-01-01

    The MIPI standard has adopted DPCM compression for RAW data images streamed from mobile cameras. This DPCM is line based and uses either a simple 1 or 2 pixel predictor. In this paper, we analyze the DPCM compression performance as MTF degradation. To test this scheme's performance, we generated Siemens star images and binarized them to 2-level images. These two intensity values where chosen such that their intensity difference corresponds to those pixel differences which result in largest relative errors in the DPCM compressor. (E.g. a pixel transition from 0 to 4095 corresponds to an error of 6 between the DPCM compressed value and the original pixel value). The DPCM scheme introduces different amounts of error based on the pixel difference. We passed these modified Siemens star chart images to this compressor and compared the compressed images with the original images using IT3 MTF response plots for slanted edges. Further, we discuss the PSF influence on DPCM error and its propagation through the image processing pipe.

  14. Compression Stockings for Treating Venous Leg Ulcers

    Directory of Open Access Journals (Sweden)

    J. P. Benigni

    2013-01-01

    Full Text Available Background. In order to treat venous leg ulcers, it is recommended to use high pressure compression (30–40 mmHg at the ankle. Compression stockings which are not operator dependant could be the best option because of their pressure control. However 30–40 mmHg compression stockings are often hard to put on. Putting two lower pressure compression stockings over each other could be a good therapeutic alternative. Objectives. To compare the in vitro pressures given by the manufacturers of 2 antiulcer kits with the in vivo interface pressures measured in healthy subjects and to evaluate the stiffness and friction indices from those kits based on the interface pressure in order to assess their clinical properties. Material and Methods. Using a Kikuhime pressure device, interface pressure was measured in 12 healthy subjects at the reference point B1. One stiffness index (Static Stiffness Index (SSI and a friction index have been calculated. Results. Mediven Ulcer kit gets the recommended pressures whereas Jobst’s Ulcer Care kit does not for treating a venous leg ulcer. Jobst’s Ulcer Care transmits entirely the pressure in relation to a friction index close to 1. Conclusion. This antiulcer kit study underlines that in vivo and in vitro pressures can be different (Jobst’s Ulcer Care kit and Mediven Ulcer kit. In order not to lose pressure, it is important to take into account the friction index when superimposing two stockings.

  15. Compressive Multispectral Spectrum Sensing for Spectrum Cartography

    Directory of Open Access Journals (Sweden)

    Jeison Marín Alfonso

    2018-01-01

    Full Text Available In the process of spectrum sensing applied to wireless communications, it is possible to build interference maps based on acquired power spectral values. This allows the characterization of spectral occupation, which is crucial to take management spectrum decisions. However, the amount of information both in the space and frequency domains that needs to be processed generates an enormous amount of data with high transmission delays and high memory requirements. Meanwhile, compressive sensing is a technique that allows the reconstruction of sparse or compressible signals using fewer samples than those required by the Nyquist criterion. This paper presents a new model that uses compressed multispectral sampling for spectrum sensing. The aim is to reduce the number of data required for the storage and the subsequent construction of power spectral maps with geo-referenced information in different frequency bands. This model is based on architectures that use compressive sensing to analyze multispectral images. The operation of a centralized manager is presented in order to select the power data of different sensors by binary patterns. These sensors are located in different geographical positions. The centralized manager reconstructs a data cube with the transmitted power and frequency of operation of all the sensors based on the samples taken and applying multispectral sensing techniques. The results show that this multispectral data cube can be built with 50% of the samples generated by the devices, and the spectrum cartography information can be stored using only 6.25% of the original data.

  16. Dynamic mode decomposition for compressive system identification

    Science.gov (United States)

    Bai, Zhe; Kaiser, Eurika; Proctor, Joshua L.; Kutz, J. Nathan; Brunton, Steven L.

    2017-11-01

    Dynamic mode decomposition has emerged as a leading technique to identify spatiotemporal coherent structures from high-dimensional data. In this work, we integrate and unify two recent innovations that extend DMD to systems with actuation and systems with heavily subsampled measurements. When combined, these methods yield a novel framework for compressive system identification, where it is possible to identify a low-order model from limited input-output data and reconstruct the associated full-state dynamic modes with compressed sensing, providing interpretability of the state of the reduced-order model. When full-state data is available, it is possible to dramatically accelerate downstream computations by first compressing the data. We demonstrate this unified framework on simulated data of fluid flow past a pitching airfoil, investigating the effects of sensor noise, different types of measurements (e.g., point sensors, Gaussian random projections, etc.), compression ratios, and different choices of actuation (e.g., localized, broadband, etc.). This example provides a challenging and realistic test-case for the proposed method, and results indicate that the dominant coherent structures and dynamics are well characterized even with heavily subsampled data.

  17. Compressive Multispectral Spectrum Sensing for Spectrum Cartography.

    Science.gov (United States)

    Marín Alfonso, Jeison; Martínez Torre, Jose Ignacio; Arguello Fuentes, Henry; Agudelo, Leonardo Betancur

    2018-01-29

    In the process of spectrum sensing applied to wireless communications, it is possible to build interference maps based on acquired power spectral values. This allows the characterization of spectral occupation, which is crucial to take management spectrum decisions. However, the amount of information both in the space and frequency domains that needs to be processed generates an enormous amount of data with high transmission delays and high memory requirements. Meanwhile, compressive sensing is a technique that allows the reconstruction of sparse or compressible signals using fewer samples than those required by the Nyquist criterion. This paper presents a new model that uses compressed multispectral sampling for spectrum sensing. The aim is to reduce the number of data required for the storage and the subsequent construction of power spectral maps with geo-referenced information in different frequency bands. This model is based on architectures that use compressive sensing to analyze multispectral images. The operation of a centralized manager is presented in order to select the power data of different sensors by binary patterns. These sensors are located in different geographical positions. The centralized manager reconstructs a data cube with the transmitted power and frequency of operation of all the sensors based on the samples taken and applying multispectral sensing techniques. The results show that this multispectral data cube can be built with 50% of the samples generated by the devices, and the spectrum cartography information can be stored using only 6.25% of the original data.

  18. Science-driven 3D data compression

    Science.gov (United States)

    Alonso, David

    2018-02-01

    Photometric redshift surveys map the distribution of matter in the Universe through the positions and shapes of galaxies with poorly resolved measurements of their radial coordinates. While a tomographic analysis can be used to recover some of the large-scale radial modes present in the data, this approach suffers from a number of practical shortcomings, and the criteria to decide on a particular binning scheme are commonly blind to the ultimate science goals. We present a method designed to separate and compress the data into a small number of uncorrelated radial modes, circumventing some of the problems of standard tomographic analyses. The method is based on the Karhunen-Loève transform (KL), and is connected to other 3D data compression bases advocated in the literature, such as the Fourier-Bessel decomposition. We apply this method to both weak lensing and galaxy clustering. In the case of galaxy clustering, we show that the resulting optimal basis is closely associated with the Fourier-Bessel basis, and that for certain observables, such as the effects of magnification bias or primordial non-Gaussianity, the bulk of the signal can be compressed into a small number of modes. In the case of weak lensing, we show that the method is able to compress the vast majority of the signal-to-noise ratio into a single mode, and that optimal cosmological constraints can be obtained considering only three uncorrelated KL eigenmodes, considerably simplifying the analysis with respect to a traditional tomographic approach.

  19. HPV16 DNA status is a strong prognosticator of loco-regional control after postoperative radiochemotherapy of locally advanced oropharyngeal carcinoma: results from a multicentre explorative study of the German Cancer Consortium Radiation Oncology Group (DKTK-ROG).

    Science.gov (United States)

    Lohaus, Fabian; Linge, Annett; Tinhofer, Inge; Budach, Volker; Gkika, Eleni; Stuschke, Martin; Balermpas, Panagiotis; Rödel, Claus; Avlar, Melanie; Grosu, Anca-Ligia; Abdollahi, Amir; Debus, Jürgen; Bayer, Christine; Belka, Claus; Pigorsch, Steffi; Combs, Stephanie E; Mönnich, David; Zips, Daniel; von Neubeck, Cläre; Baretton, Gustavo B; Löck, Steffen; Thames, Howard D; Krause, Mechthild; Baumann, Michael

    2014-12-01

    To investigate the impact of HPV status in patients with locally advanced head and neck squamous cell carcinoma (HNSCC), who received surgery and cisplatin-based postoperative radiochemotherapy. For 221 patients with locally advanced squamous cell carcinoma of the hypopharynx, oropharynx or oral cavity treated at the 8 partner sites of the German Cancer Consortium, the impact of HPV DNA, p16 overexpression and p53 expression on outcome were retrospectively analysed. The primary endpoint was loco-regional tumour control; secondary endpoints were distant metastases and overall survival. In the total patient population, univariate analyses revealed a significant impact of HPV16 DNA positivity, p16 overexpression, p53 positivity and tumour site on loco-regional tumour control. Multivariate analysis stratified for tumour site showed that positive HPV 16 DNA status correlated with loco-regional tumour control in patients with oropharyngeal carcinoma (p=0.02) but not in the oral cavity carcinoma group. Multivariate evaluation of the secondary endpoints in the total population revealed a significant association of HPV16 DNA positivity with overall survival (p<0.01) but not with distant metastases. HPV16 DNA status appears to be a strong prognosticator of loco-regional tumour control after postoperative cisplatin-based radiochemotherapy of locally advanced oropharyngeal carcinoma and is now being explored in a prospective validation trial. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. <strong>Relative Biological Effect of Antiprotonsstrong>> strong>

    DEFF Research Database (Denmark)

    Bassler, Niels; Holzscheiter, Michael

    purpose/objective The AD-4/ACE collaboration has recently performed experiments to directly measure the RBE of antiprotons. Antiprotons have very similar stopping power compared to protons, but when they come to rest, antiprotons will annihilate on a target nucleus and thereby release almost 2 Ge......V of energy. About 30 MeV of this energy is deposited in the vicinity of the Bragg-peak, thereby significantly enhancing it. It is furthermore expected that this additional energy is deposited by radiation which carries a high-LET component. This will have a significant influence on the radiobiological...... nuclear research facility CERN. A beam of 126 MeV antiprotons, corresponding to about 12 cm range in water, was spread out to a SOBP with a width of 1 cm. Dosimetry experiments were carried out with ionization chambers, alanine pellets and radiochromic film, and the results were used for benchmarking...

  1. Data Compression of Hydrocarbon Reservoir Simulation Grids

    KAUST Repository

    Chavez, Gustavo Ivan

    2015-05-28

    A dense volumetric grid coming from an oil/gas reservoir simulation output is translated into a compact representation that supports desired features such as interactive visualization, geometric continuity, color mapping and quad representation. A set of four control curves per layer results from processing the grid data, and a complete set of these 3-dimensional surfaces represents the complete volume data and can map reservoir properties of interest to analysts. The processing results yield a representation of reservoir simulation results which has reduced data storage requirements and permits quick performance interaction between reservoir analysts and the simulation data. The degree of reservoir grid compression can be selected according to the quality required, by adjusting for different thresholds, such as approximation error and level of detail. The processions results are of potential benefit in applications such as interactive rendering, data compression, and in-situ visualization of large-scale oil/gas reservoir simulations.

  2. AIRMaster: Compressed air system audit software

    International Nuclear Information System (INIS)

    Wheeler, G.M.; Bessey, E.G.; McGill, R.D.; Vischer, K.

    1997-01-01

    The project goal was to develop a software tool, AIRMaster, and a methodology for performing compressed air system audits. AIRMaster and supporting manuals are designed for general auditors or plant personnel to evaluate compressed air system operation with simple instrumentation during a short-term audit. AIRMaster provides a systematic approach to compressed air system audits, analyzing collected data, and reporting results. AIRMaster focuses on inexpensive Operation and Maintenance (O and M) measures, such as fixing air leaks and improving controls that can significantly improve performance and reliability of the compressed air system, without significant risk to production. An experienced auditor can perform an audit, analyze collected data, and produce results in 2--3 days. AIRMaster reduces the cost of an audit, thus freeing funds to implement recommendations. The AIRMaster package includes an Audit Manual, Software and User's manual, Analysis Methodology Manual, and a Case Studies summary report. It also includes a Self-Guided Tour booklet to help users quickly screen a plant for efficiency improvement potentials, and an Industrial Compressed Air Systems Energy Efficiency Guidebook. AIRMaster proved to be a fast and effective audit tool. In sever audits AIRMaster identified energy savings of 4,056,000 kWh, or 49.2% of annual compressor energy use, for a cost savings of $152,000. Total implementation costs were $94,700 for a project payback period of 0.6 years. Available airflow increased between 11% and 51% of plant compressor capacity, leading to potential capital benefits from 40% to 230% of first year energy savings

  3. Composition-Structure-Property Relations of Compressed Borosilicate Glasses

    Science.gov (United States)

    Svenson, Mouritz N.; Bechgaard, Tobias K.; Fuglsang, Søren D.; Pedersen, Rune H.; Tjell, Anders Ø.; Østergaard, Martin B.; Youngman, Randall E.; Mauro, John C.; Rzoska, Sylwester J.; Bockowski, Michal; Smedskjaer, Morten M.

    2014-08-01

    Hot isostatic compression is an interesting method for modifying the structure and properties of bulk inorganic glasses. However, the structural and topological origins of the pressure-induced changes in macroscopic properties are not yet well understood. In this study, we report on the pressure and composition dependences of density and micromechanical properties (hardness, crack resistance, and brittleness) of five soda-lime borosilicate glasses with constant modifier content, covering the extremes from Na-Ca borate to Na-Ca silicate end members. Compression experiments are performed at pressures ≤1.0 GPa at the glass transition temperature in order to allow processing of large samples with relevance for industrial applications. In line with previous reports, we find an increasing fraction of tetrahedral boron, density, and hardness but a decreasing crack resistance and brittleness upon isostatic compression. Interestingly, a strong linear correlation between plastic (irreversible) compressibility and initial trigonal boron content is demonstrated, as the trigonal boron units are the ones most disposed for structural and topological rearrangements upon network compaction. A linear correlation is also found between plastic compressibility and the relative change in hardness with pressure, which could indicate that the overall network densification is responsible for the increase in hardness. Finally, we find that the micromechanical properties exhibit significantly different composition dependences before and after pressurization. The findings have important implications for tailoring microscopic and macroscopic structures of glassy materials and thus their properties through the hot isostatic compression method.

  4. BENEFITS AND CHALLENGES OF VARIABLE COMPRESSION RATIO AT DIESEL ENGINES

    Directory of Open Access Journals (Sweden)

    Radivoje B Pešić

    2010-01-01

    Full Text Available The compression ratio strongly affects the working process and provides an exceptional degree of control over engine performance. In conventional internal combustion engines, the compression ratio is fixed and their performance is therefore a compromise between conflicting requirements. One fundamental problem is that drive units in the vehicles must successfully operate at variable speeds and loads and in different ambient conditions. If a diesel engine has a fixed compression ratio, a minimal value must be chosen that can achieve a reliable self-ignition when starting the engine in cold start conditions. In diesel engines, variable compression ratio provides control of peak cylinder pressure, improves cold start ability and low load operation, enabling the multi-fuel capability, increase of fuel economy and reduction of emissions. This paper contains both theoretical and experimental investigation of the impact that automatic variable compression ratios has on working process parameters in experimental diesel engine. Alternative methods of implementing variable compression ratio are illustrated and critically examined.

  5. Preliminary investigation of biological resistance, water absorption and swelling of thermally compressed pine wood panels

    Science.gov (United States)

    Oner Unsal; S. Nami Kartal; Zeki Candan; Rachel Arango; Carol A. Clausen; Frederick Green

    2008-01-01

    Wood can be modified by compressive, thermal and chemical treatments. Compression of wood under thermal conditions is resulted in densification of wood. This study evaluated decay and termite resistance of thermally compressed pine wood panels at either 5 or 7 MPa and at either 120 or 150°C for one hour. The process caused increases in density and decreases in...

  6. The theory of temporal compression of intense pulses in a metal vapor

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, M.J.; Crane, J.K.

    1990-11-16

    We examine compression of near-resonant pulses in metal vapor in the nonlinear regime. Our calculations examine nonlinear effects on compression of optimally-chirped pulses of various fluences. In addition, we compare model predictions with experimental results for compression of 4 nsec Nd:YAG pumped dye pulses.

  7. The impact of water content and ionic diffusion on the uniaxial compressive strength of shale

    Directory of Open Access Journals (Sweden)

    Talal AL-Bazali

    2013-12-01

    Finally, the impact of ionic diffusion on the compressive strength of shale was carried out in the absence of both chemical osmosis and capillary forces. Results show that the invasion of sodium and calcium ions into shale reduced its compressive strength considerably while the invasion of potassium ions enhanced its compressive strength.

  8. Adaptive Integration of the Compressed Algorithm of CS and NPC for the ECG Signal Compressed Algorithm in VLSI Implementation

    Directory of Open Access Journals (Sweden)

    Yun-Hua Tseng

    2017-10-01

    Full Text Available Compressed sensing (CS is a promising approach to the compression and reconstruction of electrocardiogram (ECG signals. It has been shown that following reconstruction, most of the changes between the original and reconstructed signals are distributed in the Q, R, and S waves (QRS region. Furthermore, any increase in the compression ratio tends to increase the magnitude of the change. This paper presents a novel approach integrating the near-precise compressed (NPC and CS algorithms. The simulation results presented notable improvements in signal-to-noise ratio (SNR and compression ratio (CR. The efficacy of this approach was verified by fabricating a highly efficient low-cost chip using the Taiwan Semiconductor Manufacturing Company’s (TSMC 0.18-μm Complementary Metal-Oxide-Semiconductor (CMOS technology. The proposed core has an operating frequency of 60 MHz and gate counts of 2.69 K.

  9. The quest for 'diagnostically lossless' medical image compression: a comparative study of objective quality metrics for compressed medical images

    Science.gov (United States)

    Kowalik-Urbaniak, Ilona; Brunet, Dominique; Wang, Jiheng; Koff, David; Smolarski-Koff, Nadine; Vrscay, Edward R.; Wallace, Bill; Wang, Zhou

    2014-03-01

    Our study, involving a collaboration with radiologists (DK,NSK) as well as a leading international developer of medical imaging software (AGFA), is primarily concerned with improved methods of assessing the diagnostic quality of compressed medical images and the investigation of compression artifacts resulting from JPEG and JPEG2000. In this work, we compare the performances of the Structural Similarity quality measure (SSIM), MSE/PSNR, compression ratio CR and JPEG quality factor Q, based on experimental data collected in two experiments involving radiologists. An ROC and Kolmogorov-Smirnov analysis indicates that compression ratio is not always a good indicator of visual quality. Moreover, SSIM demonstrates the best performance, i.e., it provides the closest match to the radiologists' assessments. We also show that a weighted Youden index1 and curve tting method can provide SSIM and MSE thresholds for acceptable compression ratios.

  10. Compressive sensing for urban radar

    CERN Document Server

    Amin, Moeness

    2014-01-01

    With the emergence of compressive sensing and sparse signal reconstruction, approaches to urban radar have shifted toward relaxed constraints on signal sampling schemes in time and space, and to effectively address logistic difficulties in data acquisition. Traditionally, these challenges have hindered high resolution imaging by restricting both bandwidth and aperture, and by imposing uniformity and bounds on sampling rates.Compressive Sensing for Urban Radar is the first book to focus on a hybrid of two key areas: compressive sensing and urban sensing. It explains how reliable imaging, tracki

  11. Strong Coupling Gauge Theories in LHC ERA

    Science.gov (United States)

    Fukaya, H.; Harada, M.; Tanabashi, M.; Yamawaki, K.

    2011-01-01

    AdS/QCD, light-front holography, and the nonperturbative running coupling / Stanley J. Brodsky, Guy de Teramond and Alexandre Deur -- New results on non-abelian vortices - Further insights into monopole, vortex and confinement / K. Konishi -- Study on exotic hadrons at B-factories / Toru Iijima -- Cold compressed baryonic matter with hidden local symmetry and holography / Mannque Rho -- Aspects of baryons in holographic QCD / T. Sakai -- Nuclear force from string theory / K. Hashimoto -- Integrating out holographic QCD back to hidden local symmetry / Masayasu Harada, Shinya Matsuzaki and Koichi Yamawaki -- Holographic heavy quarks and the giant Polyakov loop / Gianluca Grignani, Joanna Karczmarek and Gordon W. Semenoff -- Effect of vector-axial-vector mixing to dilepton spectrum in hot and/or dense matter / Masayasu Harada and Chihiro Sasaki -- Infrared behavior of ghost and gluon propagators compatible with color confinement in Yang-Mills theory with the Gribov horizon / Kei-Ichi Kondo -- Chiral symmetry breaking on the lattice / Hidenori Fukaya [for JLQCD and TWQCD collaborations] -- Gauge-Higgs unification: Stable Higgs bosons as cold dark matter / Yutaka Hosotani -- The limits of custodial symmetry / R. Sekhar Chivukula ... [et al.] -- Higgs searches at the tevatron / Kazuhiro Yamamoto [for the CDF and D[symbol] collaborations] -- The top triangle moose / R. S. Chivukula ... [et al.] -- Conformal phase transition in QCD like theories and beyond / V. A. Miransky -- Gauge-Higgs unification at LHC / Nobuhito Maru and Nobuchika Okada -- W[symbol]W[symbol] scattering in Higgsless models: Identifying better effective theories / Alexander S. Belyaev ... [et al.] -- Holographic estimate of Muon g - 2 / Deog Ki Hong -- Gauge-Higgs dark matter / T. Yamashita -- Topological and curvature effects in a multi-fermion interaction model / T. Inagaki and M. Hayashi -- A model of soft mass generation / J. Hosek -- TeV physics and conformality / Thomas Appelquist -- Conformal

  12. Deformation Behavior and Evolution of Microstructure and Texture During Hot Compression of AISI 304LN Stainless Steel

    Science.gov (United States)

    Rout, Matruprasad; Biswas, Somjeet; Ranjan, Ravi; Pal, Surjya Kanta; Singh, Shiv Brat

    2018-03-01

    Deformation behavior of hot-rolled AISI 304 LN austenitic stainless steel was studied by hot axisymmetric compression tests at 1173 K, 1273 K, and 1373 K (900 °C, 1000 °C, and 1100 °C) at strain rates of 0.01, 0.1, and 1 s-1. The flow curves were examined to understand the deformation characteristics. The influence of Zener-Holloman parameter was analyzed using appropriate constitutive models. The activation energy for deformation was found to be 473 kJ/mol. Quantitative microstructural analysis was carried out using Electron backscattered diffraction. Compression at 1173 K (900 °C) at all true strain rates gave rise to partially dynamic recrystallized microstructure with strong α-fiber texture. The deformation texture is characterized by the formation of Brass component, and partial dynamic recrystallization (DRX) led to the development of Goss, S, and ube components. Necklace structure of small equiaxed recrystallized grains could be observed surrounding the large, elongated deformed grains. Compressions at 1273 K and 1373 K (1000 °C and 1100 °C) resulted in fully recrystallized microstructure consisting of mostly Σ3 and Σ9 coincidence site lattice high-angle boundaries. Compression at 1273 K (1000 °C) leads to the formation of low-intensity diffused α-fiber. DRX was confirmed by the presence of Goss, S, Cube, and rotated Cube components. Compression performed at 1373 K (1100 °C) resulted in nearly random texture with traces of α-fiber and prominent Cube/rotated Cube components. The microstructures of the 1173 K (900 °C)-compressed samples were partitioned using grain size and misorientation criteria to quantify DRX.

  13. Evaluation of Tunable Data Compression in Energy-Aware Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Beihua Ying

    2010-04-01

    Full Text Available Energy is an important consideration in wireless sensor networks. In the current compression evaluations, traditional indices are still used, while energy efficiency is probably neglected. Moreover, various evaluation biases significantly affect the final results. All these factors lead to a subjective evaluation. In this paper, a new criterion is proposed and a series of tunable compression algorithms are reevaluated. The results show that the new criterion makes the evaluation more objective. Additionally it indicates the situations when compression is unnecessary. A new adaptive compression arbitration system is proposed based on the evaluation results, which improves the performance of compression algorithms.

  14. Strong Plate, Weak Slab Dichotomy

    Science.gov (United States)

    Petersen, R. I.; Stegman, D. R.; Tackley, P.

    2015-12-01

    Models of mantle convection on Earth produce styles of convection that are not observed on Earth.Moreover non-Earth-like modes, such as two-sided downwellings, are the de facto mode of convection in such models.To recreate Earth style subduction, i.e. one-sided asymmetric recycling of the lithosphere, proper treatment of the plates and plate interface are required. Previous work has identified several model features that promote subduction. A free surface or pseudo-free surface and a layer of material with a relatively low strength material (weak crust) allow downgoing plates to bend and slide past overriding without creating undue stress at the plate interface. (Crameri, et al. 2012, GRL)A low viscosity mantle wedge, possibly a result of slab dehydration, decouples the plates in the system. (Gerya et al. 2007, Geo)Plates must be composed of material which, in the case of the overriding plate, are is strong enough to resist bending stresses imposed by the subducting plate and yet, as in the case of the subducting plate, be weak enough to bend and subduct when pulled by the already subducted slab. (Petersen et al. 2015, PEPI) Though strong surface plates are required for subduction such plates may present a problem when they encounter the lower mantle.As the subducting slab approaches the higher viscosity, lower mantle stresses are imposed on the tip.Strong slabs transmit this stress to the surface.There the stress field at the plate interface is modified and potentially modifies the style of convection. In addition to modifying the stress at the plate interface, the strength of the slab affects the morphology of the slab at the base of the upper mantle. (Stegman, et al 2010, Tectonophysics)Slabs that maintain a sufficient portion of their strength after being bent require high stresses to unbend or otherwise change their shape.On the other hand slabs that are weakened though the bending process are more amenable to changes in morphology. We present the results of

  15. [Experimental study on spectra of compressed air microwave plasma].

    Science.gov (United States)

    Liu, Yong-Xi; Zhang, Gui-Xin; Wang, Qiang; Hou, Ling-Yun

    2013-03-01

    Using a microwave plasma generator, compressed air microwave plasma was excited under 1 - 5 atm pressures. Under different pressures and different incident microwave power, the emission spectra of compressed air microwave plasma were studied with a spectra measuring system. The results show that continuum is significant at atmospheric pressure and the characteristic will be weakened as the pressure increases. The band spectra intensity will be reduced with the falling of the incident microwave power and the band spectra were still significant. The experimental results are valuable to studying the characteristics of compressed air microwave plasma and the generating conditions of NO active groups.

  16. Ultrasonic data compression via parameter estimation.

    Science.gov (United States)

    Cardoso, Guilherme; Saniie, Jafar

    2005-02-01

    Ultrasonic imaging in medical and industrial applications often requires a large amount of data collection. Consequently, it is desirable to use data compression techniques to reduce data and to facilitate the analysis and remote access of ultrasonic information. The precise data representation is paramount to the accurate analysis of the shape, size, and orientation of ultrasonic reflectors, as well as to the determination of the properties of the propagation path. In this study, a successive parameter estimation algorithm based on a modified version of the continuous wavelet transform (CWT) to compress and denoise ultrasonic signals is presented. It has been shown analytically that the CWT (i.e., time x frequency representation) yields an exact solution for the time-of-arrival and a biased solution for the center frequency. Consequently, a modified CWT (MCWT) based on the Gabor-Helstrom transform is introduced as a means to exactly estimate both time-of-arrival and center frequency of ultrasonic echoes. Furthermore, the MCWT also has been used to generate a phase x bandwidth representation of the ultrasonic echo. This representation allows the exact estimation of the phase and the bandwidth. The performance of this algorithm for data compression and signal analysis is studied using simulated and experimental ultrasonic signals. The successive parameter estimation algorithm achieves a data compression ratio of (1-5N/J), where J is the number of samples and N is the number of echoes in the signal. For a signal with 10 echoes and 2048 samples, a compression ratio of 96% is achieved with a signal-to-noise ratio (SNR) improvement above 20 dB. Furthermore, this algorithm performs robustly, yields accurate echo estimation, and results in SNR enhancements ranging from 10 to 60 dB for composite signals having SNR as low as -10 dB.

  17. Kyphoplasty for severe osteoporotic vertebral compression fractures

    International Nuclear Information System (INIS)

    Bao Zhaohua; Wang Genlin; Yang Huilin; Meng Bin; Chen Kangwu; Jiang Weimin

    2010-01-01

    Objective: To evaluate the clininal efficacy of kyphoplasty for severe osteoporotic vertebral compression fractures. Methods: Forty-five patients with severe osteoporotic compressive fractures were treated by kyphoplasty from Jan 2005 to Jan 2009. The compressive rate of the fractured vertebral bodies was more than 75%. According to the morphology of the vertebral compression fracture bodies the unilateral or bilateral balloon kyphoplasty were selected. The anterior vertebral height was measured on a standing lateral radiograph at pre-operative, post-operative (one day after operation) and final follow-up time. A visual analog scale(VAS) and the Oswestry disability index (ODI) were chosen to evaluate pain status and functional activity. Results: The mean follow-up was for 21.7 months (in range from 18 to 48 months). The anterior vertebral body height of fracture vertebra was restored from preoperative (18.7 ± 3.1)% to postoperative (51.4 ± 2.3)%, the follow-up period (50.2 ± 2.7)%. There was a significant improvement between preoperative and postoperative values (P 0.05). The VAS was 8.1 ± 1.4 at preoperative, 2.6 ± 0.9 at postoperative, 2.1 ± 0.5 at final follow-up time; and the ODI was preoperative 91.1 ± 2.3, postoperative 30.7 ± 7.1, follow-up period 26.1 ± 5.1. There was statistically significant improvement in the VAS and ODI in the post-operative assessment compared with the pre-operative assessment (P 0.05). Asymptomatic cement leakage occurred in three cases. New vertebral fracture occurred in one case. Conclusion: The study suggests that balloon kyphoplasty is a safe and effective procedure in the treatment of severe osteoporotic vertebral compression fractures. (authors)

  18. Geotechnical issues and guidelines for storage of compressed air in excavated hard rock caverns

    Energy Technology Data Exchange (ETDEWEB)

    Allen, R.D.; Doherty, T.J.; Fossum, A.F.

    1982-04-01

    The results of a literature survey on the stability of excavated hard rock caverns are presented. The objective of the study was to develop geotechnical criteria for the design of compressed air energy storage (CAES) caverns in hard rock formations. These criteria involve geologic, hydrological, geochemical, geothermal, and in situ stress state characteristics of generic rock masses. Their relevance to CAES caverns, and the identification of required research areas, are identified throughout the text. This literature survey and analysis strongly suggests that the chief geotechnical issues for the development and operation of CAES caverns in hard rock are impermeability for containment, stability for sound openings, and hydrostatic balance.

  19. Low-Complexity Compression Algorithm for Hyperspectral Images Based on Distributed Source Coding

    Directory of Open Access Journals (Sweden)

    Yongjian Nian

    2013-01-01

    Full Text Available A low-complexity compression algorithm for hyperspectral images based on distributed source coding (DSC is proposed in this paper. The proposed distributed compression algorithm can realize both lossless and lossy compression, which is implemented by performing scalar quantization strategy on the original hyperspectral images followed by distributed lossless compression. Multilinear regression model is introduced for distributed lossless compression in order to improve the quality of side information. Optimal quantized step is determined according to the restriction of the correct DSC decoding, which makes the proposed algorithm achieve near lossless compression. Moreover, an effective rate distortion algorithm is introduced for the proposed algorithm to achieve low bit rate. Experimental results show that the compression performance of the proposed algorithm is competitive with that of the state-of-the-art compression algorithms for hyperspectral images.

  20. Amount of systemic steroid medication is a strong predictor for the use of complementary and alternative medicine in patients with inflammatory bowel disease: results from a German national survey.

    Science.gov (United States)

    Langhorst, Jost; Anthonisen, Inga B; Steder-Neukamm, Ulf; Lüdtke, Rainer; Spahn, Guenther; Michalsen, Andreas; Dobos, Gustav J

    2005-03-01

    Previous studies have suggested that inflammatory bowel disease (IBD) patients rank high among users of complementary and alternative medicine (CAM). To further elucidate this phenomenon, we sent questionnaires to a large sample of IBD patients in Germany to determine the patterns and predictors of their CAM use. Pretested 73-item questionnaires were mailed to a randomly selected representative sample of 1000 IBD patients from the approximately 16,000 members and associates of the German Crohn's and Colitis Association. Predictors of CAM use were evaluated by logistic regression models. Completed questionnaires were returned by 684 patients (female patients, 61.4%; Crohn's disease patients, 58.3%; ulcerative colitis patients, 38.2%). Of the 671 adult respondents, 344 (51.3%) had experience with CAM, and significantly more of the ulcerative colitis patients (59.8%) than the Crohn's disease patients (48.3%) had experience with CAM. There was no difference by gender. Homeopathy (52.9%) and herbal medicine (43.6%) were the most commonly used types of CAM. The most frequent personal reasons for CAM use were the search for an "optimum treatment" (78.9%) and the wish to stop taking steroids (63.8%). Using logistic regression, we found that total cortisone intake (P = 0.0077), but not duration of disease, was a strong predictor of CAM use. Other predictors were experience with psychosomatic and psychotherapeutic support (P = 0.0029), relaxation techniques (P = 0.0284), an academic education (P = 0.0173), a diet utilizing whole grains (P = 0.0123), and a normal body weight (P = 0.0215). Although 80% of patients indicated that they were interested in using CAM in the future, only 24.7% felt sufficiently informed about it. More than 50% of a large group of German IBD patients had used CAM. Prolonged or intensive steroid treatment, an academic education, active ways of coping, and a health-conscious life-style are associated with CAM use. Given the potential side effects and

  1. Compression Fracture of CFRP Laminates Containing Stress Intensifications.

    Science.gov (United States)

    Leopold, Christian; Schütt, Martin; Liebig, Wilfried V; Philipkowski, Timo; Kürten, Jonas; Schulte, Karl; Fiedler, Bodo

    2017-09-05

    For brittle fracture behaviour of carbon fibre reinforced plastics (CFRP) under compression, several approaches exist, which describe different mechanisms during failure, especially at stress intensifications. The failure process is not only initiated by the buckling fibres, but a shear driven fibre compressive failure beneficiaries or initiates the formation of fibres into a kink-band. Starting from this kink-band further damage can be detected, which leads to the final failure. The subject of this work is an experimental investigation on the influence of ply thickness and stacking sequence in quasi-isotropic CFRP laminates containing stress intensifications under compression loading. Different effects that influence the compression failure and the role the stacking sequence has on damage development and the resulting compressive strength are identified and discussed. The influence of stress intensifications is investigated in detail at a hole in open hole compression (OHC) tests. A proposed interrupted test approach allows identifying the mechanisms of damage initiation and propagation from the free edge of the hole by causing a distinct damage state and examine it at a precise instant of time during fracture process. Compression after impact (CAI) tests are executed in order to compare the OHC results to a different type of stress intensifications. Unnotched compression tests are carried out for comparison as a reference. With this approach, a more detailed description of the failure mechanisms during the sudden compression failure of CFRP is achieved. By microscopic examination of single plies from various specimens, the different effects that influence the compression failure are identified. First damage of fibres occurs always in 0°-ply. Fibre shear failure leads to local microbuckling and the formation and growth of a kink-band as final failure mechanisms. The formation of a kink-band and finally steady state kinking is shifted to higher compressive strains

  2. Strongly coupled dust coulomb clusters

    International Nuclear Information System (INIS)

    Juan Wentau; Lai Yingju; Chen Mingheng; I Lin

    1999-01-01

    The structures and motions of quasi-2-dimensional strongly coupled dust Coulomb clusters with particle number N from few to hundreds in a cylindrical rf plasma trap are studied and compared with the results from the molecular dynamic simulation using more ideal models. Shell structures with periodic packing in different shells and intershell rotational motion dominated excitations are observed at small N. As N increases, the boundary has less effect, the system recovers to the triangular lattice with isotropic vortex type cooperative excitations similar to an infinite N system except the outer shell region. The above generic behaviors are mainly determined by the system symmetry and agree with the simulation results. The detailed interaction form causes minor effect such as the fine structure of packing

  3. Observation of soliton compression in silicon photonic crystals

    Science.gov (United States)

    Blanco-Redondo, A.; Husko, C.; Eades, D.; Zhang, Y.; Li, J.; Krauss, T.F.; Eggleton, B.J.

    2014-01-01

    Solitons are nonlinear waves present in diverse physical systems including plasmas, water surfaces and optics. In silicon, the presence of two photon absorption and accompanying free carriers strongly perturb the canonical dynamics of optical solitons. Here we report the first experimental demonstration of soliton-effect pulse compression of picosecond pulses in silicon, despite two photon absorption and free carriers. Here we achieve compression of 3.7 ps pulses to 1.6 ps with soliton-based functionalities in complementary metal-oxide-semiconductor-compatible platforms. PMID:24423977

  4. Compressive spectroscopy by spectral modulation

    Science.gov (United States)

    Oiknine, Yaniv; August, Isaac; Stern, Adrian

    2017-05-01

    We review two compressive spectroscopy techniques based on modulation in the spectral domain that we have recently proposed. Both techniques achieve a compression ratio of approximately 10:1, however each with a different sensing mechanism. The first technique uses a liquid crystal cell as a tunable filter to modulate the spectral signal, and the second technique uses a Fabry-Perot etalon as a resonator. We overview the specific properties of each of the techniques.

  5. The combined compression and shear of a rectangular rubber block

    Science.gov (United States)

    Hill, James M.; Myers, Timothy G.

    1992-09-01

    For long rectangular rubber blocks with metal plates bonded to their upper and lower surfaces, approximate force-deflection relations are obtained for the problem of combined compression (or tension) and shear. The results obtained generalise that of Klingbeil and Shield for the case of pure compression alone, as well as incorporating the well known simple shear result. However, unlike the pure compression solution, horizontal and vertical force resultants on the free surfaces cannot both be set to zero, which is a well known characteristic of simple shearing. Here the strategy is adopted of equating to zero only the horizontal force resultants on the free surfaces so that the pure compression approximation of Klingbeil and Shield emerges in the event of zero shear. The force-deflection relations so obtained are illustrated graphically.

  6. Acceptance Test Report for 241-U compressed air system

    International Nuclear Information System (INIS)

    Freeman, R.D.

    1994-01-01

    This Acceptance Test Report (ATR) documents the results of acceptance testing of a newly upgraded compressed air system at 241-U Farm. The system was installed and the test successfully performed under work package 2W-92-01027

  7. EDF - 2012 full-year results: Strong results and commitments delivered. Confirmation of the solidity of EDF's integrated and diversified business model. Annual results 2012. Electricite de France S.A.: Statutory Auditors' Report on the consolidated financial statements. Management report 2012

    International Nuclear Information System (INIS)

    2013-01-01

    As the world's biggest electricity generator, the EDF Group covers every sector of expertise, from generation to trading and transmission grids. EDF builds on the expertise of its people, its R and D and engineering skills, its experience as a leading industry operator and the attentive support of its customers to deliver competitive solutions that successfully reconcile economic growth with climate protection. This document presents the 2012 annual results, management report and Consolidated financial statements of the Group at 31 December 2012: EBITDA: euro 16.1 billion, +7.7% of which 4.6% organic growth; Net income excluding non-recurring items: euro 4.2 billion, +16.9%; Net income - Group share: euro 3.3 billion, + 5.3%; Allocation in 2013 of the CSPE receivable to dedicated assets, bringing coverage of eligible provisions to 100% starting as early as 2013; Net financial debt/EBITDA: 2.4x2; Proposed dividend of euro 1.25/share for the 20123 financial year, i.e. a pay-out ratio of 55% of net income excluding non-recurring items. 2013: a decisive year: Launch of 'Spark': plan targeting savings of euro 1 billion as soon as 2013; EBITDA: between 0% and 3% in organic growth excluding Edison; Edison: expectation for recurring EBITDA in line with 2012, with fluctuation in results possible in 2013-2014 linked to calendar effect from the re-negotiation of gas supply contracts; Net investments stable at euro 12 billion; Net financial debt/EBITDA: between 2x and 2.5x; Pay-out ratio: between 55% and 65% of net income excluding non-recurring items. Consolidated Financial Statements: Group accounting standards; comparability; significant events and transactions; regulatory events in France; changes in the scope of consolidation; segment reporting; sales; fuel and energy purchases; other external expenses; personnel expenses; taxes other than income taxes; other operating income and expenses; impairment / reversals; other income and expenses; financial result

  8. Experimental study of tensile strength of pharmaceutical tablets: effect of the diluent nature and compression pressure

    Science.gov (United States)

    Juban, Audrey; Briançon, Stéphanie; Puel, François; Hoc, Thierry; Nouguier-Lehon, Cécile

    2017-06-01

    In the pharmaceutical field, tablets are the most common dosage form for oral administration in the world. Among different manufacturing processes, direct compression is widely used because of its economics interest and it is a process which avoids the steps of wet granulation and drying processes. Tablets are composed of at least two ingredients: an active pharmaceutical ingredient (API) which is mixed with a diluent. The nature of the powders and the processing conditions are crucial for the properties of the blend and, consequently, strongly influence the mechanical characteristics of tablets. Moreover, tablets have to present a suitable mechanical strength to avoid crumbling or breaking when handling, while ensuring an appropriate disintegration after administration. Accordingly, this mechanical property is an essential parameter to consider. Experimental results showed that proportion of the diluent, fragmentary (DCPA) or plastic (MCC), had a large influence on the tensile strength evolution with API content as well as the compression load applied during tableting process. From these results a model was developed in order to predict the tensile strength of binary tablets by knowing the compression pressure. The validity of this model was demonstrated for the two studied systems and a comparison was made with two existing models.

  9. Experimental study of tensile strength of pharmaceutical tablets: effect of the diluent nature and compression pressure

    Directory of Open Access Journals (Sweden)

    Juban Audrey

    2017-01-01

    Full Text Available In the pharmaceutical field, tablets are the most common dosage form for oral administration in the world. Among different manufacturing processes, direct compression is widely used because of its economics interest and it is a process which avoids the steps of wet granulation and drying processes. Tablets are composed of at least two ingredients: an active pharmaceutical ingredient (API which is mixed with a diluent. The nature of the powders and the processing conditions are crucial for the properties of the blend and, consequently, strongly influence the mechanical characteristics of tablets. Moreover, tablets have to present a suitable mechanical strength to avoid crumbling or breaking when handling, while ensuring an appropriate disintegration after administration. Accordingly, this mechanical property is an essential parameter to consider. Experimental results showed that proportion of the diluent, fragmentary (DCPA or plastic (MCC, had a large influence on the tensile strength evolution with API content as well as the compression load applied during tableting process. From these results a model was developed in order to predict the tensile strength of binary tablets by knowing the compression pressure. The validity of this model was demonstrated for the two studied systems and a comparison was made with two existing models.

  10. Compression Models for Plasma Focus Devices

    International Nuclear Information System (INIS)

    Gonzalez, Jose; Calusse, Alejandro; Ramos, Ruben; Rodriguez Palomino, Luis

    2003-01-01

    Using a numerical model that calculates the dynamics of Plasma Focus devices, we compared the results of three different compression models of the plasma pinch.One of the main objectives in this area is to develop a simplified model to calculate the neutron production of Plasma Focus devices, to study the influence of the main parameters in this neutron yield.The dynamics is thoroughly studied, and the model predicts fairly well values such as maximum currents and times for pinch collapse.Therefore, we evaluate here different models of pinch compression, to try to predict the neutron production with good agreement with the rest of the variables involved.To fulfill this requirement, we have experimental results of neutron production as a function of deuterium filling pressure in the chamber, and typical values of other main variables in the dynamics of the current sheet

  11. Asymptotic stability of steady compressible fluids

    CERN Document Server

    Padula, Mariarosaria

    2011-01-01

    This volume introduces a systematic approach to the solution of some mathematical problems that arise in the study of the hyperbolic-parabolic systems of equations that govern the motions of thermodynamic fluids. It is intended for a wide audience of theoretical and applied mathematicians with an interest in compressible flow, capillarity theory, and control theory. The focus is particularly on recent results concerning nonlinear asymptotic stability, which are independent of assumptions about the smallness of the initial data. Of particular interest is the loss of control that sometimes results when steady flows of compressible fluids are upset by large disturbances. The main ideas are illustrated in the context of three different physical problems: (i) A barotropic viscous gas in a fixed domain with compact boundary. The domain may be either an exterior domain or a bounded domain, and the boundary may be either impermeable or porous. (ii) An isothermal viscous gas in a domain with free boundaries. (iii) A h...

  12. Can compression reduce forensic image time?

    Directory of Open Access Journals (Sweden)

    Brian Cusack

    Full Text Available Creating a forensic copy (image of a hard disk drive is one of the fundamental tasks a computer forensic analyst must perform. Time is often critical, and there is a need to consider a trade-off between a number of factors to achieve best results. This paper reports the results from an exploratory study into the impact of using disk drive compression on the time needed to image (and verify a hard disk drive. It was found that time reduction may be achieved once the trade-off of contributing variables was properly estimated. The findings led the investigators to suggest a step-by-step decision making process for analysts when considering disk compression as a means for reducing total image processing time.

  13. Compression force-depth relationship during out-of-hospital cardiopulmonary resuscitation.

    Science.gov (United States)

    Tomlinson, A E; Nysaether, J; Kramer-Johansen, J; Steen, P A; Dorph, E

    2007-03-01

    Recent clinical studies reporting the high frequency of inadequate chest compression depth (compression depth in certain patients. Using a specially designed monitor/defibrillator equipped with a sternal pad fitted with an accelerometer and a pressure sensor, compression force and depth was measured during CPR in 91 adult out-of-hospital cardiac arrest patients. There was a strong non-linear relationship between the force of compression and depth achieved. Mean applied force for all patients was 30.3+/-8.2 kg and mean absolute compression depth 42+/-8 mm. For 87 of 91 patients 38 mm compression depth was obtained with less than 50 kg. Stiffer chests were compressed more forcefully than softer chests (pcompressed more deeply than stiffer chests (p=0.001). The force needed to reach 38 mm compression depth (F38) and mean compression force were higher for males than for females: 29.8+/-14.5 kg versus 22.5+/-10.2 kg (pcompression depth with age, but a significant 1.5 kg mean decrease in applied force for each 10 years increase in age (pcompressions performed. Average residual force during decompression was 1.7+/-1.0 kg, corresponding to an average residual depth of 3+/-2 mm. In most out-of-hospital cardiac arrest victims adequate chest compression depth can be achieved by a force<50 kg, indicating that an average sized and fit rescuer should be able to perform effective CPR in most adult patients.

  14. Bi-level image compression with tree coding

    DEFF Research Database (Denmark)

    Martins, Bo; Forchhammer, Søren

    1996-01-01

    are constructed by this principle. A multi-pass free tree coding scheme produces superior compression results for all test images. A multi-pass fast free template coding scheme produces much better results than JBIG for difficult images, such as halftonings. Rissanen's algorithm `Context' is presented in a new...... version that without sacrificing speed brings it close to the multi-pass coders in compression performance...

  15. Numerical simulation of 2D and 3D compressible flows

    Science.gov (United States)

    Huml, Jaroslav; Kozel, Karel; Příhoda, Jaromír

    2013-02-01

    The work deals with numerical solutions of 2D inviscid and laminar compressible flows in the GAMM channel and DCA 8% cascade, and of 3D inviscid compressible flows in a 3D modification of the GAMM channel (Swept Wing). The FVM multistage Runge-Kutta method and the Lax-Wendroff scheme (Richtmyer's form) with Jameson's artificial dissipation were applied to obtain the numerical solutions. The results are discussed and compared to other similar results and experiments.

  16. Relativistically strong electromagnetic radiation in a plasma

    Science.gov (United States)

    Bulanov, S. V.; Esirkepov, T. Zh.; Kando, M.; Kiriyama, H.; Kondo, K.

    2016-03-01

    Physical processes in a plasma under the action of relativistically strong electromagnetic waves generated by high-power lasers have been briefly reviewed. These processes are of interest in view of the development of new methods for acceleration of charged particles, creation of sources of bright hard electromagnetic radiation, and investigation of macroscopic quantum-electrodynamical processes. Attention is focused on nonlinear waves in a laser plasma for the creation of compact electron accelerators. The acceleration of plasma bunches by the radiation pressure of light is the most efficient regime of ion acceleration. Coherent hard electromagnetic radiation in the relativistic plasma is generated in the form of higher harmonics and/or electromagnetic pulses, which are compressed and intensified after reflection from relativistic mirrors created by nonlinear waves. In the limit of extremely strong electromagnetic waves, radiation friction, which accompanies the conversion of radiation from the optical range to the gamma range, fundamentally changes the behavior of the plasma. This process is accompanied by the production of electron-positron pairs, which is described within quantum electrodynamics theory.

  17. Compression and heating of a laser-produced plasma using single and double induction coils

    Science.gov (United States)

    Creel, J. R.; Lunney, J. G.

    2018-02-01

    The results of an experiment on magnetohydrodynamic compression and heating of a laser-produced plasma in vacuum are described. The plasma was produced by laser ablation of copper at 2 J cm-2. A pulsed magnetic field, with an amplitude of 0.3 T and a period of 2.2 µs, was produced by a three-turn spiral induction coil placed 10 mm above the ablation spot. Time-resolved imaging revealed that the magnetic field had a strong influence on both the plasma between the coil and the target, and on the plasma which flows through the aperture in the coil. The plasma flow through the coil aperture is strongly pinched due to the Lorentz interaction of the induced current and the coil magnetic field. Heating of the plasma is evidenced by strong enhancement of the overall visible light emission and the appearance of Cu+ line emission. Magnetic compression and plasma heating were also observed in a setup using two induction coils separated by 10 mm. This technique could be used to enhance the sensitivity of laser-induced breakdown spectroscopy, increase the ion yield in laser plasma ion sources, or control the ablation plume expansion in pulsed laser deposition.

  18. A new compressed air energy storage refrigeration system

    International Nuclear Information System (INIS)

    Wang Shenglong; Chen Guangming; Fang Ming; Wang Qin

    2006-01-01

    In this study, a new compressed air energy storage (CAES) refrigeration system is proposed for electrical power load shifting application. It is a combination of a gas refrigeration cycle and a vapor compression refrigeration cycle. Thermodynamic calculations are conducted to investigate the performance of this system. Economic analysis is performed to study the operating cost of the system, and comparison is made with a vapor compression refrigeration system and an ice storage refrigeration system. The results indicate that the CAES refrigeration system has the advantages of simple structure, high efficiency and low operating cost

  19. Probability densities in strong turbulence

    Science.gov (United States)

    Yakhot, Victor

    2006-03-01

    In this work we, using Mellin’s transform combined with the Gaussian large-scale boundary condition, calculate probability densities (PDFs) of velocity increments P(δu,r), velocity derivatives P(u,r) and the PDF of the fluctuating dissipation scales Q(η,Re), where Re is the large-scale Reynolds number. The resulting expressions strongly deviate from the Log-normal PDF P(δu,r) often quoted in the literature. It is shown that the probability density of the small-scale velocity fluctuations includes information about the large (integral) scale dynamics which is responsible for the deviation of P(δu,r) from P(δu,r). An expression for the function D(h) of the multifractal theory, free from spurious logarithms recently discussed in [U. Frisch, M. Martins Afonso, A. Mazzino, V. Yakhot, J. Fluid Mech. 542 (2005) 97] is also obtained.

  20. Double-compression method for biomedical images

    Science.gov (United States)

    Antonenko, Yevhenii A.; Mustetsov, Timofey N.; Hamdi, Rami R.; Małecka-Massalska, Teresa; Orshubekov, Nurbek; DzierŻak, RóŻa; Uvaysova, Svetlana

    2017-08-01

    This paper describes a double compression method (DCM) of biomedical images. A comparison of image compression factors in size JPEG, PNG and developed DCM was carried out. The main purpose of the DCM - compression of medical images while maintaining the key points that carry diagnostic information. To estimate the minimum compression factor an analysis of the coding of random noise image is presented.

  1. 29 CFR 1917.154 - Compressed air.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a...

  2. Influence of video compression on the measurement error of the television system

    Science.gov (United States)

    Sotnik, A. V.; Yarishev, S. N.; Korotaev, V. V.

    2015-05-01

    Video data require a very large memory capacity. Optimal ratio quality / volume video encoding method is one of the most actual problem due to the urgent need to transfer large amounts of video over various networks. The technology of digital TV signal compression reduces the amount of data used for video stream representation. Video compression allows effective reduce the stream required for transmission and storage. It is important to take into account the uncertainties caused by compression of the video signal in the case of television measuring systems using. There are a lot digital compression methods. The aim of proposed work is research of video compression influence on the measurement error in television systems. Measurement error of the object parameter is the main characteristic of television measuring systems. Accuracy characterizes the difference between the measured value abd the actual parameter value. Errors caused by the optical system can be selected as a source of error in the television systems measurements. Method of the received video signal processing is also a source of error. Presence of error leads to large distortions in case of compression with constant data stream rate. Presence of errors increases the amount of data required to transmit or record an image frame in case of constant quality. The purpose of the intra-coding is reducing of the spatial redundancy within a frame (or field) of television image. This redundancy caused by the strong correlation between the elements of the image. It is possible to convert an array of image samples into a matrix of coefficients that are not correlated with each other, if one can find corresponding orthogonal transformation. It is possible to apply entropy coding to these uncorrelated coefficients and achieve a reduction in the digital stream. One can select such transformation that most of the matrix coefficients will be almost zero for typical images . Excluding these zero coefficients also

  3. Physics of Strongly Coupled Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Kraeft, Wolf-Dietrich [Universitat Rostock (Germany)

    2007-07-15

    Strongly coupled plasmas (or non-ideal plasmas) are multi-component charged many-particle systems, in which the mean value of the potential energy of the system is of the same order as or even higher than the mean value of the kinetic energy. The constituents are electrons, ions, atoms and molecules. Dusty (or complex) plasmas contain still mesoscopic (multiply charged) particles. In such systems, the effects of strong coupling (non-ideality) lead to considerable deviations of physical properties from the corresponding properties of ideal plasmas, i.e., of plasmas in which the mean kinetic energy is essentially larger than the mean potential energy. For instance, bound state energies become density dependent and vanish at higher densities (Mott effect) due to the interaction of the pair with the surrounding particles. Non-ideal plasmas are of interest both for general scientific reasons (including, for example, astrophysical questions), and for technical applications such as inertially confined fusion. In spite of great efforts both experimentally and theoretically, satisfactory information on the physical properties of strongly coupled plasmas is not at hand for any temperature and density. For example, the theoretical description of non-ideal plasmas is possible only at low densities/high temperatures and at extremely high densities (high degeneracy). For intermediate degeneracy, however, numerical experiments have to fill the gap. Experiments are difficult in the region of 'warm dense matter'. The monograph tries to present the state of the art concerning both theoretical and experimental attempts. It mainly includes results of the work performed in famous Russian laboratories in recent decades. After outlining basic concepts (chapter 1), the generation of plasmas is considered (chapter 2, chapter 3). Questions of partial (chapter 4) and full ionization (chapter 5) are discussed including Mott transition and Wigner crystallization. Electrical and

  4. New Regenerative Cycle for Vapor Compression Refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Mark J. Bergander

    2005-08-29

    second step of compression. In the proposed system, the compressor compresses the vapor only to 50-60% of the final pressure, while the additional compression is provided by a jet device using internal potential energy of the working fluid flow. Therefore, the amount of mechanical energy required by a compressor is significantly reduced, resulting in the increase of efficiency (either COP or EER). The novelty of the cycle is in the equipment and in the way the multi-staging is accomplished. The anticipated result will be a new refrigeration system that requires less energy to accomplish a cooling task. The application of this technology will be for more efficient designs of: (1) Industrial chillers, (2) Refrigeration plants, (3) Heat pumps, (4) Gas Liquefaction plants, (5) Cryogenic systems.

  5. Study of the stress-strain state of compressed concrete elements with composite reinforcement

    Directory of Open Access Journals (Sweden)

    Bondarenko Yurii

    2017-01-01

    Full Text Available The efficiency analysis of the application of glass composite reinforcement in compressed concrete elements as a load-carrying component has been performed. The results of experimental studies of the deformation-strength characteristics of this reinforcement on compression and compressed concrete cylinders reinforced by this reinforcement are presented. The results of tests and mechanisms of sample destruction have been analyzed. The numerical analysis of the stress-strain state has been performed for axial compression of concrete elements with glasscomposite reinforcement. The influence of the reinforcement percentage on the stressed state of a concrete compressed element with the noted reinforcement is estimated. On the basis of the obtained results, it is established that the glass-composite reinforcement has positive effect on the strength of the compressed concrete elements. That is, when calculating the load-bearing capacity of such structures, the function of composite reinforcement on compression should not be neglected.

  6. Efficient Joins with Compressed Bitmap Indexes

    Energy Technology Data Exchange (ETDEWEB)

    Computational Research Division; Madduri, Kamesh; Wu, Kesheng

    2009-08-19

    We present a new class of adaptive algorithms that use compressed bitmap indexes to speed up evaluation of the range join query in relational databases. We determine the best strategy to process a join query based on a fast sub-linear time computation of the join selectivity (the ratio of the number of tuples in the result to the total number of possible tuples). In addition, we use compressed bitmaps to represent the join output compactly: the space requirement for storing the tuples representing the join of two relations is asymptotically bounded by min(h; n . cb), where h is the number of tuple pairs in the result relation, n is the number of tuples in the smaller of the two relations, and cb is the cardinality of the larger column being joined. We present a theoretical analysis of our algorithms, as well as experimental results on large-scale synthetic and real data sets. Our implementations are efficient, and consistently outperform well-known approaches for a range of join selectivity factors. For instance, our count-only algorithm is up to three orders of magnitude faster than the sort-merge approach, and our best bitmap index-based algorithm is 1.2x-80x faster than the sort-merge algorithm, for various query instances. We achieve these speedups by exploiting several inherent performance advantages of compressed bitmap indexes for join processing: an implicit partitioning of the attributes, space-efficiency, and tolerance of high-cardinality relations.

  7. An efficient and extensible approach for compressing phylogenetic trees

    KAUST Repository

    Matthews, Suzanne J

    2011-01-01

    Background: Biologists require new algorithms to efficiently compress and store their large collections of phylogenetic trees. Our previous work showed that TreeZip is a promising approach for compressing phylogenetic trees. In this paper, we extend our TreeZip algorithm by handling trees with weighted branches. Furthermore, by using the compressed TreeZip file as input, we have designed an extensible decompressor that can extract subcollections of trees, compute majority and strict consensus trees, and merge tree collections using set operations such as union, intersection, and set difference.Results: On unweighted phylogenetic trees, TreeZip is able to compress Newick files in excess of 98%. On weighted phylogenetic trees, TreeZip is able to compress a Newick file by at least 73%. TreeZip can be combined with 7zip with little overhead, allowing space savings in excess of 99% (unweighted) and 92%(weighted). Unlike TreeZip, 7zip is not immune to branch rotations, and performs worse as the level of variability in the Newick string representation increases. Finally, since the TreeZip compressed text (TRZ) file contains all the semantic information in a collection of trees, we can easily filter and decompress a subset of trees of interest (such as the set of unique trees), or build the resulting consensus tree in a matter of seconds. We also show the ease of which set operations can be performed on TRZ files, at speeds quicker than those performed on Newick or 7zip compressed Newick files, and without loss of space savings.Conclusions: TreeZip is an efficient approach for compressing large collections of phylogenetic trees. The semantic and compact nature of the TRZ file allow it to be operated upon directly and quickly, without a need to decompress the original Newick file. We believe that TreeZip will be vital for compressing and archiving trees in the biological community. © 2011 Matthews and Williams; licensee BioMed Central Ltd.

  8. Perceptual Image Compression in Telemedicine

    Science.gov (United States)

    Watson, Andrew B.; Ahumada, Albert J., Jr.; Eckstein, Miguel; Null, Cynthia H. (Technical Monitor)

    1996-01-01

    The next era of space exploration, especially the "Mission to Planet Earth" will generate immense quantities of image data. For example, the Earth Observing System (EOS) is expected to generate in excess of one terabyte/day. NASA confronts a major technical challenge in managing this great flow of imagery: in collection, pre-processing, transmission to earth, archiving, and distribution to scientists at remote locations. Expected requirements in most of these areas clearly exceed current technology. Part of the solution to this problem lies in efficient image compression techniques. For much of this imagery, the ultimate consumer is the human eye. In this case image compression should be designed to match the visual capacities of the human observer. We have developed three techniques for optimizing image compression for the human viewer. The first consists of a formula, developed jointly with IBM and based on psychophysical measurements, that computes a DCT quantization matrix for any specified combination of viewing distance, display resolution, and display brightness. This DCT quantization matrix is used in most recent standards for digital image compression (JPEG, MPEG, CCITT H.261). The second technique optimizes the DCT quantization matrix for each individual image, based on the contents of the image. This is accomplished by means of a model of visual sensitivity to compression artifacts. The third technique extends the first two techniques to the realm of wavelet compression. Together these two techniques will allow systematic perceptual optimization of image compression in NASA imaging systems. Many of the image management challenges faced by NASA are mirrored in the field of telemedicine. Here too there are severe demands for transmission and archiving of large image databases, and the imagery is ultimately used primarily by human observers, such as radiologists. In this presentation I will describe some of our preliminary explorations of the applications

  9. Compressed Measurements Based Spectrum Sensing for Wideband Cognitive Radio Systems

    Directory of Open Access Journals (Sweden)

    Taha A. Khalaf

    2015-01-01

    Full Text Available Spectrum sensing is the most important component in the cognitive radio (CR technology. Spectrum sensing has considerable technical challenges, especially in wideband systems where higher sampling rates are required which increases the complexity and the power consumption of the hardware circuits. Compressive sensing (CS is successfully deployed to solve this problem. Although CS solves the higher sampling rate problem, it does not reduce complexity to a large extent. Spectrum sensing via CS technique is performed in three steps: sensing compressed measurements, reconstructing the Nyquist rate signal, and performing spectrum sensing on the reconstructed signal. Compressed detectors perform spectrum sensing from the compressed measurements skipping the reconstruction step which is the most complex step in CS. In this paper, we propose a novel compressed detector using energy detection technique on compressed measurements sensed by the discrete cosine transform (DCT matrix. The proposed algorithm not only reduces the computational complexity but also provides a better performance than the traditional energy detector and the traditional compressed detector in terms of the receiver operating characteristics. We also derive closed form expressions for the false alarm and detection probabilities. Numerical results show that the analytical expressions coincide with the exact probabilities obtained from simulations.

  10. Lossless Compression Schemes for ECG Signals Using Neural Network Predictors

    Directory of Open Access Journals (Sweden)

    C. Eswaran

    2007-01-01

    Full Text Available This paper presents lossless compression schemes for ECG signals based on neural network predictors and entropy encoders. Decorrelation is achieved by nonlinear prediction in the first stage and encoding of the residues is done by using lossless entropy encoders in the second stage. Different types of lossless encoders, such as Huffman, arithmetic, and runlength encoders, are used. The performances of the proposed neural network predictor-based compression schemes are evaluated using standard distortion and compression efficiency measures. Selected records from MIT-BIH arrhythmia database are used for performance evaluation. The proposed compression schemes are compared with linear predictor-based compression schemes and it is shown that about 11% improvement in compression efficiency can be achieved for neural network predictor-based schemes with the same quality and similar setup. They are also compared with other known ECG compression methods and the experimental results show that superior performances in terms of the distortion parameters of the reconstructed signals can be achieved with the proposed schemes.

  11. ADVANCED RECIPROCATING COMPRESSION TECHNOLOGY (ARCT). FINAL REPORT

    International Nuclear Information System (INIS)

    Danny M. Deffenbaugh; Klaus Brun; Ralph E. Harris; J. Pete Harrell; Robert J. Mckee; J. Jeffrey Moore; Steven J. Svedeman; Anthony J. Smalley; Eugene L. Broerman; Robert A Hart; Marybeth G. Nored; Ryan S. Gernentz; Shane P. Siebenaler

    2005-01-01

    The U.S. natural gas pipeline industry is facing the twin challenges of increased flexibility and capacity expansion. To meet these challenges, the industry requires improved choices in gas compression to address new construction and enhancement of the currently installed infrastructure. The current fleet of installed reciprocating compression is primarily slow-speed integral machines. Most new reciprocating compression is and will be large, high-speed separable units. The major challenges with the fleet of slow-speed integral machines are: limited flexibility and a large range in performance. In an attempt to increase flexibility, many operators are choosing to single-act cylinders, which are causing reduced reliability and integrity. While the best performing units in the fleet exhibit thermal efficiencies between 90% and 92%, the low performers are running down to 50% with the mean at about 80%. The major cause for this large disparity is due to installation losses in the pulsation control system. In the better performers, the losses are about evenly split between installation losses and valve losses. The major challenges for high-speed machines are: cylinder nozzle pulsations, mechanical vibrations due to cylinder stretch, short valve life, and low thermal performance. To shift nozzle pulsation to higher orders, nozzles are shortened, and to dampen the amplitudes, orifices are added. The shortened nozzles result in mechanical coupling with the cylinder, thereby, causing increased vibration due to the cylinder stretch mode. Valve life is even shorter than for slow speeds and can be on the order of a few months. The thermal efficiency is 10% to 15% lower than slow-speed equipment with the best performance in the 75% to 80% range. The goal of this advanced reciprocating compression program is to develop the technology for both high speed and low speed compression that will expand unit flexibility, increase thermal efficiency, and increase reliability and integrity

  12. Schwannosis induced medullary compression in VACTERL syndrome.

    LENUS (Irish Health Repository)

    Treacy, A

    2011-10-21

    A 7-year-old boy with a history of VACTERL syndrome was found collapsed in bed. MRI had shown basilar invagination of the skull base and narrowing of the foramen magnum. Angulation, swelling and abnormal high signal at the cervicomedullary junction were felt to be secondary to compression of the medulla. Neuropathologic examination showed bilateral replacement of the medullary tegmentum by an irregularly circumscribed cellular lesion which was composed of elongated GFAP\\/S 100-positive cells with spindled nuclei and minimal atypia. The pathologic findings were interpreted as intramedullary schwannosis with mass effect. Schwannosis, is observed in traumatized spinal cords where its presence may represent attempted, albeit aberrant, repair by inwardly migrating Schwann cells ofperipheral origin. In our view the compressive effect of the basilar invagination on this boy\\'s medulla was of sufficient magnitude to have caused tumoral medullary schwannosis with resultant intermittent respiratory compromise leading to reflex anoxic seizures.

  13. Lossless Compression of JPEG Coded Photo Collections.

    Science.gov (United States)

    Wu, Hao; Sun, Xiaoyan; Yang, Jingyu; Zeng, Wenjun; Wu, Feng

    2016-04-06

    The explosion of digital photos has posed a significant challenge to photo storage and transmission for both personal devices and cloud platforms. In this paper, we propose a novel lossless compression method to further reduce the size of a set of JPEG coded correlated images without any loss of information. The proposed method jointly removes inter/intra image redundancy in the feature, spatial, and frequency domains. For each collection, we first organize the images into a pseudo video by minimizing the global prediction cost in the feature domain. We then present a hybrid disparity compensation method to better exploit both the global and local correlations among the images in the spatial domain. Furthermore, the redundancy between each compensated signal and the corresponding target image is adaptively reduced in the frequency domain. Experimental results demonstrate the effectiveness of the proposed lossless compression method. Compared to the JPEG coded image collections, our method achieves average bit savings of more than 31%.

  14. Compressive strength of thick composite panels

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter

    2011-01-01

    The aim of this study is to investigate how much the compressive strength of thick composite panels is reduced due to delaminations and to investigate under which conditions a delamination will grow. Understanding of this is essential in order to move forward the design limits used in the structu......The aim of this study is to investigate how much the compressive strength of thick composite panels is reduced due to delaminations and to investigate under which conditions a delamination will grow. Understanding of this is essential in order to move forward the design limits used...... in the structural design process. Results obtained from finite element modeling analyses are compared with an experimental test campaign performed on flat composite panels with and without delaminations....

  15. Compressed Sensing Adaptive Speech Characteristics Research

    Directory of Open Access Journals (Sweden)

    Long Tao

    2014-09-01

    Full Text Available The sparsity of the speech signals is utilized in the DCT domain. According to the characteristics of the voice which may be separated into voiceless and voiced one, an adaptive measurement speech recovery method is proposed in this paper based on compressed sensing. First, the observed points are distributed based on the voicing energy ratio which the entire speech segment occupies. Then the speech segment is enflamed, if the frame is an unvoiced speech, the numbers of measurement can be allocated according to its zeros and energy rate. If the frame is voiced speech, the numbers of measurement can be allocated according to its energy. The experiment results shows that the performance of speech signal based on the method above is superior to utilize compress sensing directly.

  16. Compressive sensing based ptychography image encryption

    Science.gov (United States)

    Rawat, Nitin

    2015-09-01

    A compressive sensing (CS) based ptychography combined with an optical image encryption is proposed. The diffraction pattern is recorded through ptychography technique further compressed by non-uniform sampling via CS framework. The system requires much less encrypted data and provides high security. The diffraction pattern as well as the lesser measurements of the encrypted samples serves as a secret key which make the intruder attacks more difficult. Furthermore, CS shows that the linearly projected few random samples have adequate information for decryption with a dramatic volume reduction. Experimental results validate the feasibility and effectiveness of our proposed technique compared with the existing techniques. The retrieved images do not reveal any information with the original information. In addition, the proposed system can be robust even with partial encryption and under brute-force attacks.

  17. Object specific reconstruction using compressively sensed data

    International Nuclear Information System (INIS)

    Mahalanobis, Abhijit

    2008-01-01

    Compressed sensing holds the promise for radically novel sensors that can perfectly reconstruct images using considerably less samples of data than required by the otherwise general Shannon sampling theorem. In surveillance systems however, it is also desirable to cue regions of the image where objects of interest may exist. Thus in this paper, we are interested in imaging interesting objects in a scene, without necessarily seeking perfect reconstruction of the whole image. We show that our goals are achieved by minimizing a modified L2-norm criterion with good results when the reconstruction of only specific objects is of interest. The method yields a simple closed form analytical solution that does not require iterative processing. Objects can be meaningfully sensed in considerable detail while heavily compressing the scene elsewhere. Essentially, this embeds the object detection and clutter discrimination function in the sensing and imaging process.

  18. 76 FR 4338 - Research and Development Strategies for Compressed & Cryo-Compressed Hydrogen Storage Workshops

    Science.gov (United States)

    2011-01-25

    ... DEPARTMENT OF ENERGY Research and Development Strategies for Compressed & Cryo- Compressed... Fuel Cell Technologies Program, will be hosting two days of workshops on compressed and cryo-compressed... perspectives, and overviews of carbon fiber development and recent costs analyses. The cryo-compressed hydrogen...

  19. 30 CFR 75.1730 - Compressed air; general; compressed air systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compressed air; general; compressed air systems... Compressed air; general; compressed air systems. (a) All pressure vessels shall be constructed, installed... Safety and Health district office. (b) Compressors and compressed-air receivers shall be equipped with...

  20. Effect of Kollidon VA®64 particle size and morphology as directly compressible excipient on tablet compression properties.

    Science.gov (United States)

    Chaudhary, R S; Patel, C; Sevak, V; Chan, M

    2018-01-01

    The study evaluates use of Kollidon VA ® 64 and a combination of Kollidon VA ® 64 with Kollidon VA ® 64 Fine as excipient in direct compression process of tablets. The combination of the two grades of material is evaluated for capping, lamination and excessive friability. Inter particulate void space is higher for such excipient due to the hollow structure of the Kollidon VA ® 64 particles. During tablet compression air remains trapped in the blend exhibiting poor compression with compromised physical properties of the tablets. Composition of Kollidon VA ® 64 and Kollidon VA ® 64 Fine is evaluated by design of experiment (DoE). A scanning electron microscopy (SEM) of two grades of Kollidon VA ® 64 exhibits morphological differences between coarse and fine grade. The tablet compression process is evaluated with a mix consisting of entirely Kollidon VA ® 64 and two mixes containing Kollidon VA ® 64 and Kollidon VA ® 64 Fine in ratio of 77:23 and 65:35. A statistical modeling on the results from the DoE trials resulted in the optimum composition for direct tablet compression as combination of Kollidon VA ® 64 and Kollidon VA ® 64 Fine in ratio of 77:23. This combination compressed with the predicted parameters based on the statistical modeling and applying main compression force between 5 and 15 kN, pre-compression force between 2 and 3 kN, feeder speed fixed at 25 rpm and compression range of 45-49 rpm produced tablets with hardness ranging between 19 and 21 kp, with no friability, capping, or lamination issue.