WorldWideScience

Sample records for strip theory analytical

  1. Ram Pressure Stripping Made Easy: An Analytical Approach

    Science.gov (United States)

    Köppen, J.; Jáchym, P.; Taylor, R.; Palouš, J.

    2018-06-01

    The removal of gas by ram pressure stripping of galaxies is treated by a purely kinematic description. The solution has two asymptotic limits: if the duration of the ram pressure pulse exceeds the period of vertical oscillations perpendicular to the galactic plane, the commonly used quasi-static criterion of Gunn & Gott is obtained which uses the maximum ram pressure that the galaxy has experienced along its orbit. For shorter pulses the outcome depends on the time-integrated ram pressure. This parameter pair fully describes the gas mass fraction that is stripped from a given galaxy. This approach closely reproduces results from SPH simulations. We show that typical galaxies follow a very tight relation in this parameter space corresponding to a pressure pulse length of about 300 Myr. Thus, the Gunn & Gott criterion provides a good description for galaxies in larger clusters. Applying the analytic description to a sample of 232 Virgo galaxies from the GoldMine database, we show that the ICM provides indeed the ram pressures needed to explain the deficiencies. We also can distinguish current and past strippers, including objects whose stripping state was unknown.

  2. Stripping Voltammetry

    Science.gov (United States)

    Lovrić, Milivoj

    Electrochemical stripping means the oxidative or reductive removal of atoms, ions, or compounds from an electrode surface (or from the electrode body, as in the case of liquid mercury electrodes with dissolved metals) [1-5]. In general, these atoms, ions, or compounds have been preliminarily immobilized on the surface of an inert electrode (or within it) as the result of a preconcentration step, while the products of the electrochemical stripping will dissolve in the electrolytic solution. Often the product of the electrochemical stripping is identical to the analyte before the preconcentration. However, there are exemptions to these rules. Electroanalytical stripping methods comprise two steps: first, the accumulation of a dissolved analyte onto, or in, the working electrode, and, second, the subsequent stripping of the accumulated substance by a voltammetric [3, 5], potentiometric [6, 7], or coulometric [8] technique. In stripping voltammetry, the condition is that there are two independent linear relationships: the first one between the activity of accumulated substance and the concentration of analyte in the sample, and the second between the maximum stripping current and the accumulated substance activity. Hence, a cumulative linear relationship between the maximum response and the analyte concentration exists. However, the electrode capacity for the analyte accumulation is limited and the condition of linearity is satisfied only well below the electrode saturation. For this reason, stripping voltammetry is used mainly in trace analysis. The limit of detection depends on the factor of proportionality between the activity of the accumulated substance and the bulk concentration of the analyte. This factor is a constant in the case of a chemical accumulation, but for electrochemical accumulation it depends on the electrode potential. The factor of proportionality between the maximum stripping current and the analyte concentration is rarely known exactly. In fact

  3. Analytic number theory

    CERN Document Server

    Iwaniec, Henryk

    2004-01-01

    Analytic Number Theory distinguishes itself by the variety of tools it uses to establish results, many of which belong to the mainstream of arithmetic. One of the main attractions of analytic number theory is the vast diversity of concepts and methods it includes. The main goal of the book is to show the scope of the theory, both in classical and modern directions, and to exhibit its wealth and prospects, its beautiful theorems and powerful techniques. The book is written with graduate students in mind, and the authors tried to balance between clarity, completeness, and generality. The exercis

  4. Non-Linear Wave Loads and Ship responses by a time-domain Strip Theory

    DEFF Research Database (Denmark)

    Xia, Jinzhu; Wang, Zhaohui; Jensen, Jørgen Juncher

    1998-01-01

    . Based on this time-domain strip theory, an efficient non-linear hyroelastic method of wave- and slamming-induced vertical motions and structural responses of ships is developed, where the structure is represented by the Timoshenko beam theory. Numerical calculations are presented for the S175...

  5. Information theory in analytical chemistry

    National Research Council Canada - National Science Library

    Eckschlager, Karel; Danzer, Klaus

    1994-01-01

    Contents: The aim of analytical chemistry - Basic concepts of information theory - Identification of components - Qualitative analysis - Quantitative analysis - Multicomponent analysis - Optimum analytical...

  6. Uniform physical theory of diffraction equivalent edge currents for truncated wedge strips

    DEFF Research Database (Denmark)

    Johansen, Peter Meincke

    1996-01-01

    New uniform closed-form expressions for physical theory of diffraction equivalent edge currents are derived for truncated incremental wedge strips. In contrast to previously reported expressions, the new expressions are well behaved for all directions of incidence and observation and take a finite...... value for zero strip length. This means that the expressions are well suited for implementation in general computer codes. The new expressions are expressed as the difference between two terms. The first term is obtained by integrating the exact fringe wave current on a wedge along an untruncated...

  7. The Strip Module

    DEFF Research Database (Denmark)

    Pedersen, Tommy

    1996-01-01

    When the behaviour of a ship in waves is to be predicted it is convenient to have a tool which includes different approaches to the problem.The aim of this project is to develop such a tool named the strip theory module. The strip theory module will consist of submodules dependent on the I...

  8. Analytical prediction of the heat transfer from a blood vessel near the skin surface when cooled by a symmetrical cooling strip

    Science.gov (United States)

    Chato, J. C.; Shitzer, A.

    1971-01-01

    An analytical method was developed to estimate the amount of heat extracted from an artery running close to the skin surface which is cooled in a symmetrical fashion by a cooling strip. The results indicate that the optimum width of a cooling strip is approximately three times the depth to the centerline of the artery. The heat extracted from an artery with such a strip is about 0.9 w/m-C which is too small to affect significantly the temperature of the blood flow through a main blood vessel, such as the carotid artery. The method is applicable to veins as well.

  9. Analytic thinking reduces belief in conspiracy theories.

    Science.gov (United States)

    Swami, Viren; Voracek, Martin; Stieger, Stefan; Tran, Ulrich S; Furnham, Adrian

    2014-12-01

    Belief in conspiracy theories has been associated with a range of negative health, civic, and social outcomes, requiring reliable methods of reducing such belief. Thinking dispositions have been highlighted as one possible factor associated with belief in conspiracy theories, but actual relationships have only been infrequently studied. In Study 1, we examined associations between belief in conspiracy theories and a range of measures of thinking dispositions in a British sample (N=990). Results indicated that a stronger belief in conspiracy theories was significantly associated with lower analytic thinking and open-mindedness and greater intuitive thinking. In Studies 2-4, we examined the causational role played by analytic thinking in relation to conspiracist ideation. In Study 2 (N=112), we showed that a verbal fluency task that elicited analytic thinking reduced belief in conspiracy theories. In Study 3 (N=189), we found that an alternative method of eliciting analytic thinking, which related to cognitive disfluency, was effective at reducing conspiracist ideation in a student sample. In Study 4, we replicated the results of Study 3 among a general population sample (N=140) in relation to generic conspiracist ideation and belief in conspiracy theories about the July 7, 2005, bombings in London. Our results highlight the potential utility of supporting attempts to promote analytic thinking as a means of countering the widespread acceptance of conspiracy theories. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Non-linear wave loads and ship responses by a time-domain strip theory

    DEFF Research Database (Denmark)

    Xia, Jinzhu; Wang, Zhaohui; Jensen, Jørgen Juncher

    1998-01-01

    . Based on this time-domain strip theory, an efficient non-linear hydroelastic method of wave- and slamming-induced vertical motions and structural responses of ships is developed, where the structure is represented as a Timoshenko beam. Numerical calculations are presented for the S175 Containership...

  11. From Theory Use to Theory Building in Learning Analytics: A Commentary on "Learning Analytics to Support Teachers during Synchronous CSCL"

    Science.gov (United States)

    Chen, Bodong

    2015-01-01

    In this commentary on Van Leeuwen (2015, this issue), I explore the relation between theory and practice in learning analytics. Specifically, I caution against adhering to one specific theoretical doctrine while ignoring others, suggest deeper applications of cognitive load theory to understanding teaching with analytics tools, and comment on…

  12. Theory of net analyte signal vectors in inverse regression

    DEFF Research Database (Denmark)

    Bro, R.; Andersen, Charlotte Møller

    2003-01-01

    The. net analyte signal and the net analyte signal vector are useful measures in building and optimizing multivariate calibration models. In this paper a theory for their use in inverse regression is developed. The theory of net analyte signal was originally derived from classical least squares...

  13. Analytic Summability Theory

    KAUST Repository

    Alabdulmohsin, Ibrahim M.

    2018-03-07

    The theory of summability of divergent series is a major branch of mathematical analysis that has found important applications in engineering and science. It addresses methods of assigning natural values to divergent sums, whose prototypical examples include the Abel summation method, the Cesaro means, and the Borel summability method. As will be established in subsequent chapters, the theory of summability of divergent series is intimately connected to the theory of fractional finite sums. In this chapter, we introduce a generalized definition of series as well as a new summability method for computing the value of series according to such a definition. We show that the proposed summability method is both regular and linear, and that it arises quite naturally in the study of local polynomial approximations of analytic functions. The materials presented in this chapter will be foundational to all subsequent chapters.

  14. Analytic Summability Theory

    KAUST Repository

    Alabdulmohsin, Ibrahim M.

    2018-01-01

    The theory of summability of divergent series is a major branch of mathematical analysis that has found important applications in engineering and science. It addresses methods of assigning natural values to divergent sums, whose prototypical examples include the Abel summation method, the Cesaro means, and the Borel summability method. As will be established in subsequent chapters, the theory of summability of divergent series is intimately connected to the theory of fractional finite sums. In this chapter, we introduce a generalized definition of series as well as a new summability method for computing the value of series according to such a definition. We show that the proposed summability method is both regular and linear, and that it arises quite naturally in the study of local polynomial approximations of analytic functions. The materials presented in this chapter will be foundational to all subsequent chapters.

  15. Electrochemistry and analytical determination of lysergic acid diethylamide (LSD) via adsorptive stripping voltammetry.

    Science.gov (United States)

    Merli, Daniele; Zamboni, Daniele; Protti, Stefano; Pesavento, Maria; Profumo, Antonella

    2014-12-01

    Lysergic acid diethylamide (LSD) is hardly detectable and quantifiable in biological samples because of its low active dose. Although several analytical tests are available, routine analysis of this drug is rarely performed. In this article, we report a simple and accurate method for the determination of LSD, based on adsorptive stripping voltammetry in DMF/tetrabutylammonium perchlorate, with a linear range of 1-90 ng L(-1) for deposition times of 50s. LOD of 1.4 ng L(-1) and LOQ of 4.3 ng L(-1) were found. The method can be also applied to biological samples after a simple extraction with 1-chlorobutane. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Novel cellulose-based halochromic test strips for naked-eye detection of alkaline vapors and analytes.

    Science.gov (United States)

    Abou-Yousef, Hussein; Khattab, Tawfik A; Youssef, Yehia A; Al-Balakocy, Naser; Kamel, Samir

    2017-08-01

    A simple, portable and highly sensitive naked-eye test strip is successfully prepared for optical detection of gaseous and aqueous alkaline analytes. Novel pH-sensory tricyanofuran-hydrazone (TCFH) disperse colorant containing a hydrazone recognition functional moiety is successfully synthesized via azo-coupling reaction between active methyl-containing tricyanofuran (TCF) heterocycle and diazonium salt of 4-aminobenzaldehyde followed by Knoevenagel condensation with malononitrile. UV-vis absorption spectra display solvatochromism and reversible color changes of the TCFH solution in dimethyl sulfoxide in response to pH variations. We investigate the preparation of hydrophobic cellulose/polyethylene terephthalate composites characterized by their high affinity for disperse dyes. Composite films made from CA, Cell/CA, PET/CA, and Cell/PET-CA are produced via solvent-casting procedure using 10-30% modified cellulose or modified polyethylene terephthalate. The mechanical properties and morphologies of these composite films are investigated. The prepared pH-sensory hydrazone-based disperse dye is then applied to dye the produced cellulose-based composite films employing the high temperature pressure dyeing procedure. The produced halochromic PET-CA-TCFH test strip provide an instant visible signal from orange to purple upon exposure to alkaline conditions as proved by the coloration measurements. The sensor strip exhibits high sensitivity and quick detection toward ammonia in both of aqueous and vapor phases by naked-eye observations at room temperature and atmospheric pressure. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Perturbation theory and coupling constant analyticity in two-dimensional field theories

    International Nuclear Information System (INIS)

    Simon, B.

    1973-01-01

    Conjectural material and results over a year old are presented in the discussion of perturbation theory and coupling constant analyticity in two-dimensional field theories. General properties of perturbation series are discussed rather than questions of field theory. The question is interesting for two reasons: First, one would like to understand why perturbation theory is such a good guide (to show that perturbation theory determines the theory in some way). Secondly, one hopes to prove that some or all of the theories are nontrivial. (U.S.)

  18. Non-unique factorizations algebraic, combinatorial and analytic theory

    CERN Document Server

    Geroldinger, Alfred

    2006-01-01

    From its origins in algebraic number theory, the theory of non-unique factorizations has emerged as an independent branch of algebra and number theory. Focused efforts over the past few decades have wrought a great number and variety of results. However, these remain dispersed throughout the vast literature. For the first time, Non-Unique Factorizations: Algebraic, Combinatorial, and Analytic Theory offers a look at the present state of the theory in a single, unified resource.Taking a broad look at the algebraic, combinatorial, and analytic fundamentals, this book derives factorization results and applies them in concrete arithmetical situations using appropriate transfer principles. It begins with a basic introduction that can be understood with knowledge of standard basic algebra. The authors then move to the algebraic theory of monoids, arithmetic theory of monoids, the structure of sets of lengths, additive group theory, arithmetical invariants, and the arithmetic of Krull monoids. They also provide a s...

  19. Analytical theory of noncollinear amorphous metallic magnetism

    International Nuclear Information System (INIS)

    Kakehashi, Y.; Uchida, T.

    2001-01-01

    Analytical theory of noncollinear magnetism in amorphous metals is proposed on the basis of the Gaussian model for the distribution of the interatomic distance and the saddle-point approximation. The theory removes the numerical difficulty in the previous theory based on the Monte-Carlo sampling method, and reasonably describes the magnetic properties of amorphous transition metals

  20. Contributions to Analytic Number Theory | Lucht | Quaestiones ...

    African Journals Online (AJOL)

    This paper reports on some recent contributions to the theory of multiplicative arithmetic semigroups, which have been initiated by John Knopfmacher's work on analytic number theory. They concern weighted inversion theorems of the. Wiener type, mean-value theorems for multiplicative functions, and, Ramanujan

  1. Sustainable in-well vapor stripping: A design, analytical model, and pilot study for groundwater remediation

    Science.gov (United States)

    Sutton, Patrick T.; Ginn, Timothy R.

    2014-12-01

    A sustainable in-well vapor stripping system is designed as a cost-effective alternative for remediation of shallow chlorinated solvent groundwater plumes. A solar-powered air compressor is used to inject air bubbles into a monitoring well to strip volatile organic compounds from a liquid to vapor phase while simultaneously inducing groundwater circulation around the well screen. An analytical model of the remediation process is developed to estimate contaminant mass flow and removal rates. The model was calibrated based on a one-day pilot study conducted in an existing monitoring well at a former dry cleaning site. According to the model, induced groundwater circulation at the study site increased the contaminant mass flow rate into the well by approximately two orders of magnitude relative to ambient conditions. Modeled estimates for 5 h of pulsed air injection per day at the pilot study site indicated that the average effluent concentrations of dissolved tetrachloroethylene and trichloroethylene can be reduced by over 90% relative to the ambient concentrations. The results indicate that the system could be used cost-effectively as either a single- or multi-well point technology to substantially reduce the mass of dissolved chlorinated solvents in groundwater.

  2. Adlerian and Analytic Theory: A Case Presentation.

    Science.gov (United States)

    Myers, Kathleen M.; Croake, James W.

    1984-01-01

    Makes a theoretical comparison between Adlerian and analytic formulations of family assessment in a case study involving a recently divorced couple and a child with encopresis. Discussed the family relationship in terms of object relations theory emphasizing intrapsychic experience, and Adlerian theory emphasizing the purposes of behavior. (JAC)

  3. Analytic properties of Feynman diagrams in quantum field theory

    CERN Document Server

    Todorov, I T

    1971-01-01

    Analytic Properties of Feynman Diagrams in Quantum Field Theory deals with quantum field theory, particularly in the study of the analytic properties of Feynman graphs. This book is an elementary presentation of a self-contained exposition of the majorization method used in the study of these graphs. The author has taken the intermediate position between Eden et al. who assumes the physics of the analytic properties of the S-matrix, containing physical ideas and test results without using the proper mathematical methods, and Hwa and Teplitz, whose works are more mathematically inclined with a

  4. A behavior-analytic critique of Bandura's self-efficacy theory

    Science.gov (United States)

    Biglan, Anthony

    1987-01-01

    A behavior-analytic critique of self-efficacy theory is presented. Self-efficacy theory asserts that efficacy expectations determine approach behavior and physiological arousal of phobics as well as numerous other clinically important behaviors. Evidence which is purported to support this assertion is reviewed. The evidence consists of correlations between self-efficacy ratings and other behaviors. Such response-response relationships do not unequivocally establish that one response causes another. A behavior-analytic alternative to self-efficacy theory explains these relationships in terms of environmental events. Correlations between self-efficacy rating behavior and other behavior may be due to the contingencies of reinforcement that establish a correspondence between such verbal predictions and the behavior to which they refer. Such a behavior-analytic account does not deny any of the empirical relationships presented in support of self-efficacy theory, but it points to environmental variables that could account for those relationships and that could be manipulated in the interest of developing more effective treatment procedures. PMID:22477956

  5. 7th International Conference on Elementary and Analytic Number Theory

    CERN Document Server

    Steuding, Jörn; Steuding, Rasa

    2016-01-01

    This book collects more than thirty contributions in memory of Wolfgang Schwarz, most of which were presented at the seventh International Conference on Elementary and Analytic Number Theory (ELAZ), held July 2014 in Hildesheim, Germany. Ranging from the theory of arithmetical functions to diophantine problems, to analytic aspects of zeta-functions, the various research and survey articles cover the broad interests of the well-known number theorist and cherished colleague Wolfgang Schwarz (1934-2013), who contributed over one hundred articles on number theory, its history and related fields. Readers interested in elementary or analytic number theory and related fields will certainly find many fascinating topical results among the contributions from both respected mathematicians and up-and-coming young researchers. In addition, some biographical articles highlight the life and mathematical works of Wolfgang Schwarz.

  6. Analytic solutions for marginal deformations in open superstring field theory

    International Nuclear Information System (INIS)

    Okawa, Y.

    2007-04-01

    We extend the calculable analytic approach to marginal deformations recently developed in open bosonic string field theory to open superstring field theory formulated by Berkovits. We construct analytic solutions to all orders in the deformation parameter when operator products made of the marginal operator and the associated superconformal primary field are regular. (orig.)

  7. The heuristic-analytic theory of reasoning: extension and evaluation.

    Science.gov (United States)

    Evans, Jonathan St B T

    2006-06-01

    An extensively revised heuristic-analytic theory of reasoning is presented incorporating three principles of hypothetical thinking. The theory assumes that reasoning and judgment are facilitated by the formation of epistemic mental models that are generated one at a time (singularity principle) by preconscious heuristic processes that contextualize problems in such a way as to maximize relevance to current goals (relevance principle). Analytic processes evaluate these models but tend to accept them unless there is good reason to reject them (satisficing principle). At a minimum, analytic processing of models is required so as to generate inferences or judgments relevant to the task instructions, but more active intervention may result in modification or replacement of default models generated by the heuristic system. Evidence for this theory is provided by a review of a wide range of literature on thinking and reasoning.

  8. Analytic operator approach to fermionic lattice field theories

    International Nuclear Information System (INIS)

    Duncan, A.

    1985-01-01

    An analytic Lanczos algorithm previously used to extract the spectrum of bosonic lattice field theories in the continuum region is extended to theories with fermions. The method is illustrated in detail for the (1+1)-dimensional Gross-Neveu model. All parameters in the model (coupling, lattice size N, number of fermion flavors Nsub(F), etc.) appear explicitly in analytic formulas for matrix elements of the hamiltonian. The method is applied to the calculation of the collective field vacuum expectation value and the mass gap, and excellent agreement obtained with explicit results available from the large Nsub(F) solution of the model. (orig.)

  9. Analytic theory of the gyrotron

    International Nuclear Information System (INIS)

    Lentini, P.J.

    1989-06-01

    An analytic theory is derived for a gyrotron operating in the linear gain regime. The gyrotron is a coherent source of microwave and millimeter wave radiation based on an electron beam emitting at cyclotron resonance Ω in a strong, uniform magnetic field. Relativistic equations of motion and first order perturbation theory are used. Results are obtained in both laboratory and normalized variables. An expression for cavity threshold gain is derived in the linear regime. An analytic expression for the electron phase angle in momentum space shows that the effect of the RF field is to form bunches that are equal to the unperturbed transit phase plus a correction term which varies as the sine of the input phase angle. The expression for the phase angle is plotted and bunching effects in and out of phase (0 and -π) with respect to the RF field are evident for detunings leading to gain and absorption, respectively. For exact resonance, field frequency ω = Ω, a bunch also forms at a phase of -π/2. This beam yields the same energy exchange with the RF field as an unbunched, (nonrelativistic) beam. 6 refs., 10 figs

  10. John Knopfmacher, [Abstract] Analytic Number Theory, and the ...

    African Journals Online (AJOL)

    Abstract. In this paper some important contributions of John Knopfmacher to ' Analytic Number Theory' are described. This theory investigates semigroups with countably many generators (generalized 'primes'), with a norm map (or a 'degree map'), and satisfying certain conditions on the number of elements with norm less

  11. Analytical theory of frequency-multiplying gyro-traveling-wave-tubes

    International Nuclear Information System (INIS)

    Nusinovich, G.S.; Chen, W.; Granatstein, V.L.

    2001-01-01

    The theory is developed which describes analytically the gain and bandwidth in frequency-multiplying gyro-traveling-wave-tubes. In this theory the input waveguide is considered in the small-signal approximation. Then, in the drift region separating the input and output waveguides, the electron ballistic bunching evolves which causes the appearance in the electron current density of the harmonics of the signal frequency. The excitation of the output waveguide by one of these harmonics is considered in a specified current approximation. This makes the analytical study of a large-signal operation possible. The theory is illustrated by using it to analyze the performance of an existing experimental tube

  12. AC losses in a type II superconductor strip with inhomogeneous critical current distribution

    International Nuclear Information System (INIS)

    Tsukamoto, Osami

    2005-01-01

    Analytical formulae derived by Brandt and Indenbom (1993 Phys. Rev. B 48 12893-906) and Norris (1970 J. Phys. D: Appl. Phys. 3 489-507) are often used to calculate the magnetization and AC transport current losses in HTS strip conductors, respectively. In these formulae, homogeneous distribution of critical sheet current density σ c in the strip is assumed. However, it is considered that σ c distributions are inhomogeneous in actual HTS strips and that the inhomogeneous σ c distributions cause deviations of the measured AC loss data of actual HTS strips from those formulae. A semi-analytical method to calculate AC transport current and magnetization losses is derived for a type II superconductor strip with inhomogeneous distribution of σ c in the direction of the strip width. The method is derived modifying the analysis of Brandt et al. The validity of the semi-analytical method is shown by comparing the results calculated by this method with those calculated by the Norris and Brandt formulae and by a different method of our previous work and also with experimental data. Moreover, it is shown that the deviation of the measured data from the Norris and Brandt models can be estimated by assuming proper σ c distributions

  13. Digital simulation of anodic stripping voltammetry from thin film electrodes

    International Nuclear Information System (INIS)

    Magallanes, J.F.

    1984-01-01

    The anodic stripping voltammetry (ASV) is routinely applied to control of Cu(II) in heavy water in the primary cooling loop of the Nuclear Power Reactor. The anodic stripping voltammetry (ASV) is a very well-known technique in electroanalytical chemistry. However, due to the complexity of the phenomena, it is practised with the fundamentals of empiric considerations. A geometric model for the anodic stripping voltammetry (ASV) from thin film electrodes which can be calculated by explicit digital simulation method is proposed as a possibility of solving the electrochemically reversible, cuasi-reversible and irreversible reactions under linear potential scan and multiple potential scans. (Until now the analytical mathematical method was applied to reversible reactions). All the results are compared with analytical solutions and experimental results and it permits to conclude that the anodic stripping voltammetry (ASV) can be studied with the simplicity and potentialities of explicit digital simulation methods. (M.E.L.) [es

  14. Conversational Implicature of Peanuts Comic Strip Based on Grice’s Maxim Theory

    Directory of Open Access Journals (Sweden)

    Muhartoyo Muhartoyo

    2013-04-01

    Full Text Available This article discusses about conversational implicature that occurs in Peanuts comic strips. The objectives of this study are to find out the implied meaning in the conversation between Charlie Brown with Lucy van Pelt and Lucy van Pelt with Linus van Pelt to evaluate the existence of maxim flouting and maxim violating in those conversations in relation to the four maxims such as quantity, quality, relation, and manner. Likewise, this study attempts to find out the reason for using conversational implicature in a comic strip. The writers uses a qualitative method with library research concerning to Grice’s maxim theory to analyze the conversational implicature. Based on the analysis, it can be concluded that all the comics that comprise 14 comics generate conversational implicature since all the characters breach rules of maxim. The result of this analysis shows that flouting maxim of manner has the highest occurrence of conversational implicature and the least occurrences belong to flouting maxim of relation and violating maxim of quantity. Moreover, the writers concludes that to make a successful communication ideally the speaker and the hearer to cooperate in the conversation by saying explicitly so the hearer can grasp the meaning as the goal of communication is to deliver a message to the hearer.  

  15. Analyses of edge effects on residual stresses in film strip/substrate systems

    International Nuclear Information System (INIS)

    Hsueh, Chun-Hway

    2000-01-01

    The residual stress distribution in a thin-film strip overlaid on a substrate is influenced by the edges of the strip. An analytical model is developed to derive a closed-form solution for the stress distribution along the film width. Because the film is much thinner than the substrate, the stress variation through the film thickness is ignored; however, the stress variation through the substrate thickness is considered in the analysis. Compared to the existing analytical models, the present model is more rigorous and the analytical results agree better with both finite element results and experimental measurements. (c) 2000 American Institute of Physics

  16. Causality and analyticity in quantum fields theory

    International Nuclear Information System (INIS)

    Iagolnitzer, D.

    1992-01-01

    This is a presentation of results on the causal and analytical structure of Green functions and on the collision amplitudes in fields theories, for massive particles of one type, with a positive mass and a zero spin value. (A.B.)

  17. Test strip and method for its use

    International Nuclear Information System (INIS)

    1981-01-01

    A test strip device is described which is useful in performing binding assays involving antigens, antibodies, hormones, vitamins, metabolites or pharmacological agents. The device is capable of application to analytical methods in which a set of sequential test reactions is involved and in which a minute sample size may be used. This test strip is particularly useful in radioimmunoassays. The use of the device is illustrated in radioimmunoassays for 1) thyroxine in serum, 2) the triiodothyronine binding capacity of serum and 3) folic acid and its analogues in serum. (U.K.)

  18. CLOSED-LOOP STRIPPING ANALYSIS (CLSA) OF ...

    Science.gov (United States)

    Synthetic musk compounds have been found in surface water, fish tissues, and human breast milk. Current techniques for separating these compounds from fish tissues require tedious sample clean-upprocedures A simple method for the deterrnination of these compounds in fish tissues has been developed. Closed-loop stripping of saponified fish tissues in a I -L Wheaton purge-and-trap vessel is used to strip compounds with high vapor pressures such as synthetic musks from the matrix onto a solid sorbent (Abselut Nexus). This technique is useful for screening biological tissues that contain lipids for musk compounds. Analytes are desorbed from the sorbent trap sequentially with polar and nonpolar solvents, concentrated, and directly analyzed by high resolution gas chromatography coupled to a mass spectrometer operating in the selected ion monitoring mode. In this paper, we analyzed two homogenized samples of whole fish tissues with spiked synthetic musk compounds using closed-loop stripping analysis (CLSA) and pressurized liquid extraction (PLE). The analytes were not recovered quantitatively but the extraction yield was sufficiently reproducible for at least semi-quantitative purposes (screening). The method was less expensive to implement and required significantly less sample preparation than the PLE technique. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water,

  19. Introduction to $p$-adic analytic number theory

    CERN Document Server

    Murty, M Ram

    2002-01-01

    This book is an elementary introduction to p-adic analysis from the number theory perspective. With over 100 exercises included, it will acquaint the non-expert to the basic ideas of the theory and encourage the novice to enter this fertile field of research. The main focus of the book is the study of p-adic L-functions and their analytic properties. It begins with a basic introduction to Bernoulli numbers and continues with establishing the Kummer congruences. These congruences are then used to construct the p-adic analog of the Riemann zeta function and p-adic analogs of Dirichlet's L-functions. Featured is a chapter on how to apply the theory of Newton polygons to determine Galois groups of polynomials over the rational number field. As motivation for further study, the final chapter introduces Iwasawa theory.

  20. Analytical theory of intensity fluctuations in SASE

    Energy Technology Data Exchange (ETDEWEB)

    Yu, L.H.; Krinsky, S. [Brookhaven National Lab., Upton, NY (United States). National Synchrotron Light Source

    1997-07-01

    Recent advances in SASE experiments stimulate interest in quantitative comparison of measurements with theory. Extending the previous analysis of the SASE intensity in guided modes, the authors provide an analytical description of the intensity fluctuations by calculating intensity correlation functions in the frequency domain. Comparison of the results with experiment yields new insight into the SASE process.

  1. Strip interpolation in silicon and germanium strip detectors

    International Nuclear Information System (INIS)

    Wulf, E. A.; Phlips, B. F.; Johnson, W. N.; Kurfess, J. D.; Lister, C. J.; Kondev, F.; Physics; Naval Research Lab.

    2004-01-01

    The position resolution of double-sided strip detectors is limited by the strip pitch and a reduction in strip pitch necessitates more electronics. Improved position resolution would improve the imaging capabilities of Compton telescopes and PET detectors. Digitizing the preamplifier waveform yields more information than can be extracted with regular shaping electronics. In addition to the energy, depth of interaction, and which strip was hit, the digitized preamplifier signals can locate the interaction position to less than the strip pitch of the detector by looking at induced signals in neighboring strips. This allows the position of the interaction to be interpolated in three dimensions and improve the imaging capabilities of the system. In a 2 mm thick silicon strip detector with a strip pitch of 0.891 mm, strip interpolation located the interaction of 356 keV gamma rays to 0.3 mm FWHM. In a 2 cm thick germanium detector with a strip pitch of 5 mm, strip interpolation of 356 keV gamma rays yielded a position resolution of 1.5 mm FWHM

  2. Effects of hydrostatic strain on eigenstates of Möbius strips

    DEFF Research Database (Denmark)

    Lassen, Benny; Willatzen, Morten; Gravesen, Jens

    2011-01-01

    In this paper we theoretically investigate the allowed energies and associate wave-functions for Möbius strips with varying thicknesses. We show that the induced strain in fabricating these Möbius strips will have an pronounced impact on the energies and wave-functions for thick strips, while f...... for thin strips the impact of strain is negligible. We furthermore, show that a simpler strain free approximate theory base on differential geometry is in excellent agreement with detailed finite element calculations. © 2011 IEEE....

  3. GUST86 - An analytical ephemeris of the Uranian satellites. [General Uranus Satellite Theory

    Science.gov (United States)

    Laskar, J.; Jacobson, R. A.

    1987-01-01

    The General Uranus Satellite Theory GUST (Laskar, 1986) is used for the construction of an analytical ephemeris for the Uranian satellites. The theory is fitted against earth-based observations from 1911 to 1986, and all radio and optical data obtained during Voyager encounter with Uranus. Earth-based observations alone allow the determination of masses which are within 15 percent of the values determined by the Uranus flyby. The analysis of all the observations confirm the values of the masses obtained during the encounter (Stone and Miner, 1986) and give a complete set of dynamical parameters for the analytical theory. An analytical ephemeris, GUST86, with an estimated precision of about 100 km with respect to Uranus is obtained.

  4. Factors affecting hydrocarbon removal by air stripping

    International Nuclear Information System (INIS)

    McFarland, W.E.

    1992-01-01

    This paper includes an overview of the theory of air stripping design considerations and the factors affecting stripper performance. Effects of temperature, contaminant characteristics, stripping tower geometry and air/water ratios on removal performance are discussed. The discussion includes treatment of groundwater contaminated with petroleum hydrocarbons and chlorinated solvents such as TCE and PCE. Control of VOC emissions from air strippers has become a major concern in recent years, due to more stringent restrictions on air quality in many areas. This paper includes an overview of available technology to control air emissions (including activated carbon adsorption, catalytic oxidation and steam stripping) and the effects of air emission control on overall efficiency of the treatment process. The paper includes an overview of the relative performance of various packing materials for air strippers and explains the relative advantages and disadvantages of comparative packing materials. Field conditions affecting selection of packing materials are also discussed. Practical guidelines for the design of air stripping systems are presented, as well as actual case studies of full-scale air stripping projects

  5. Analytical Implications of Using Practice Theory in Workplace Information Literacy Research

    Science.gov (United States)

    Moring, Camilla; Lloyd, Annemaree

    2013-01-01

    Introduction: This paper considers practice theory and the analytical implications of using this theoretical approach in information literacy research. More precisely the aim of the paper is to discuss the translation of practice theoretical assumptions into strategies that frame the analytical focus and interest when researching workplace…

  6. Analytical implications of using practice theory in workplace information literacy research

    DEFF Research Database (Denmark)

    Moring, Camilla Elisabeth; Lloyd, Annemaree

    2013-01-01

    Introduction: This paper considers practice theory and the analytical implications of using this theoretical approach in information literacy research. More precisely the aim of the paper is to discuss the translation of practice theoretical assumptions into strategies that frame the analytical...... focus and interest when researching workplace information literacy. Two practice theoretical perspectives are selected, one by Theodore Schatzki and one by Etienne Wenger, and their general commonalities and differences are analysed and discussed. Analysis: The two practice theories and their main ideas...... of what constitute practices, how practices frame social life and the central concepts used to explain this, are presented. Then the application of the theories within workplace information literacy research is briefly explored. Results and Conclusion: The two theoretical perspectives share some...

  7. Analytic number theory, approximation theory, and special functions in honor of Hari M. Srivastava

    CERN Document Server

    Rassias, Michael

    2014-01-01

    This book, in honor of Hari M. Srivastava, discusses essential developments in mathematical research in a variety of problems. It contains thirty-five articles, written by eminent scientists from the international mathematical community, including both research and survey works. Subjects covered include analytic number theory, combinatorics, special sequences of numbers and polynomials, analytic inequalities and applications, approximation of functions and quadratures, orthogonality, and special and complex functions. The mathematical results and open problems discussed in this book are presented in a simple and self-contained manner. The book contains an overview of old and new results, methods, and theories toward the solution of longstanding problems in a wide scientific field, as well as new results in rapidly progressing areas of research. The book will be useful for researchers and graduate students in the fields of mathematics, physics, and other computational and applied sciences.

  8. Analytic theory of alternate multilayer gratings operating in single-order regime.

    Science.gov (United States)

    Yang, Xiaowei; Kozhevnikov, Igor V; Huang, Qiushi; Wang, Hongchang; Hand, Matthew; Sawhney, Kawal; Wang, Zhanshan

    2017-07-10

    Using the coupled wave approach (CWA), we introduce the analytical theory for alternate multilayer grating (AMG) operating in the single-order regime, in which only one diffraction order is excited. Differing from previous study analogizing AMG to crystals, we conclude that symmetrical structure, or equal thickness of the two multilayer materials, is not the optimal design for AMG and may result in significant reduction in diffraction efficiency. The peculiarities of AMG compared with other multilayer gratings are analyzed. An influence of multilayer structure materials on diffraction efficiency is considered. The validity conditions of analytical theory are also discussed.

  9. Analytic multi-Regge theory and the pomeron in QCD. 1

    International Nuclear Information System (INIS)

    White, A.R.

    1991-01-01

    This paper reports on the formalism of analytic multi-Regge theory developed as a basis for the study of abstract critical and super-critical pomeron high-energy behavior and for related studies of the Regge behavior of spontaneously broken gauge theories and the pomeron in QCD. Asymptotic domains of analyticity for multiparticle amplitudes are shown to follow from properties of field theory and S-matrix theory. General asymptotic dispersion relations are then derived for such amplitudes in which the spectral components are described by the graphical formalism of hexagraphs. Further consequences are distinct Sommerfeld-Watson representations for each hexagraph spectral component, together with a complete set of angular momentum plane unitarity equations which control the form of all multi-Regge amplitudes. Because of this constraint of reggeon unitarity the critical pomeron solution of the reggeon field theory gives the only known non-trivial unitary high-energy S-matrix. By exploiting the full structure of multi-Regge amplitudes as the pomeron becomes super-critical, one can study the simultaneous modification of hadrons and the pomeron. The result is a completely consistent description of the super-critical pomeron appearing in hadron scattering. Reggeon unitarity is satisfied in the super-critical phase by the appearance of a massive gluon (Reggeized vector particle) coupling pair-wise to the pomeron

  10. Generalized thick strip modelling for vortex-induced vibration of long flexible cylinders

    International Nuclear Information System (INIS)

    Bao, Y.; Palacios, R.; Graham, M.; Sherwin, S.

    2016-01-01

    We propose a generalized strip modelling method that is computationally efficient for the VIV prediction of long flexible cylinders in three-dimensional incompressible flow. In order to overcome the shortcomings of conventional strip-theory-based 2D models, the fluid domain is divided into “thick” strips, which are sufficiently thick to locally resolve the small scale turbulence effects and three dimensionality of the flow around the cylinder. An attractive feature of the model is that we independently construct a three-dimensional scale resolving model for individual strips, which have local spanwise scale along the cylinder's axial direction and are only coupled through the structural model of the cylinder. Therefore, this approach is able to cover the full spectrum for fully resolved 3D modelling to 2D strip theory. The connection between these strips is achieved through the calculation of a tensioned beam equation, which is used to represent the dynamics of the flexible body. In the limit, however, a single “thick” strip would fill the full 3D domain. A parallel Fourier spectral/hp element method is employed to solve the 3D flow dynamics in the strip-domain, and then the VIV response prediction is achieved through the strip–structure interactions. Numerical tests on both laminar and turbulent flows as well as the comparison against the fully resolved DNS are presented to demonstrate the applicability of this approach.

  11. Generalized thick strip modelling for vortex-induced vibration of long flexible cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Bao, Y., E-mail: ybao@sjtu.edu.cn [Department of Civil Engineering, School of Naval Architecture, Ocean and Civil Engineering, Shanghai Jiaotong University, No. 800 Dongchuan Road, Shanghai (China); Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom); Palacios, R., E-mail: r.palacios@imperial.ac.uk [Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom); Graham, M., E-mail: m.graham@imperial.ac.uk [Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom); Sherwin, S., E-mail: s.sherwin@imperial.ac.uk [Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom)

    2016-09-15

    We propose a generalized strip modelling method that is computationally efficient for the VIV prediction of long flexible cylinders in three-dimensional incompressible flow. In order to overcome the shortcomings of conventional strip-theory-based 2D models, the fluid domain is divided into “thick” strips, which are sufficiently thick to locally resolve the small scale turbulence effects and three dimensionality of the flow around the cylinder. An attractive feature of the model is that we independently construct a three-dimensional scale resolving model for individual strips, which have local spanwise scale along the cylinder's axial direction and are only coupled through the structural model of the cylinder. Therefore, this approach is able to cover the full spectrum for fully resolved 3D modelling to 2D strip theory. The connection between these strips is achieved through the calculation of a tensioned beam equation, which is used to represent the dynamics of the flexible body. In the limit, however, a single “thick” strip would fill the full 3D domain. A parallel Fourier spectral/hp element method is employed to solve the 3D flow dynamics in the strip-domain, and then the VIV response prediction is achieved through the strip–structure interactions. Numerical tests on both laminar and turbulent flows as well as the comparison against the fully resolved DNS are presented to demonstrate the applicability of this approach.

  12. Analytic theory of soft x-ray diffraction by lamellar multilayer gratings

    NARCIS (Netherlands)

    Kozhevnikov, I.V.; van der Meer, R.; Bastiaens, Hubertus M.J.; Boller, Klaus J.; Bijkerk, Frederik

    2011-01-01

    An analytic theory describing soft x-ray diffraction by Lamellar Multilayer Gratings (LMG) has been developed. The theory is derived from a coupled waves approach for LMGs operating in the single-order regime, where an incident plane wave can only excite a single diffraction order. The results from

  13. Analytic stochastic regularization: gauge and supersymmetry theories

    International Nuclear Information System (INIS)

    Abdalla, M.C.B.

    1988-01-01

    Analytic stochastic regularization for gauge and supersymmetric theories is considered. Gauge invariance in spinor and scalar QCD is verified to brak fown by an explicit one loop computation of the two, theree and four point vertex function of the gluon field. As a result, non gauge invariant counterterms must be added. However, in the supersymmetric multiplets there is a cancellation rendering the counterterms gauge invariant. The calculation is considered at one loop order. (author) [pt

  14. Some elements of a theory of multidimensional complex variables. I - General theory. II - Expansions of analytic functions and application to fluid flows

    Science.gov (United States)

    Martin, E. Dale

    1989-01-01

    The paper introduces a new theory of N-dimensional complex variables and analytic functions which, for N greater than 2, is both a direct generalization and a close analog of the theory of ordinary complex variables. The algebra in the present theory is a commutative ring, not a field. Functions of a three-dimensional variable were defined and the definition of the derivative then led to analytic functions.

  15. Analytical methods applied to the study of lattice gauge and spin theories

    International Nuclear Information System (INIS)

    Moreo, Adriana.

    1985-01-01

    A study of interactions between quarks and gluons is presented. Certain difficulties of the quantum chromodynamics to explain the behaviour of quarks has given origin to the technique of lattice gauge theories. First the phase diagrams of the discrete space-time theories are studied. The analysis of the phase diagrams is made by numerical and analytical methods. The following items were investigated and studied: a) A variational technique was proposed to obtain very accurated values for the ground and first excited state energy of the analyzed theory; b) A mean-field-like approximation for lattice spin models in the link formulation which is a generalization of the mean-plaquette technique was developed; c) A new method to study lattice gauge theories at finite temperature was proposed. For the first time, a non-abelian model was studied with analytical methods; d) An abelian lattice gauge theory with fermionic matter at the strong coupling limit was analyzed. Interesting results applicable to non-abelian gauge theories were obtained. (M.E.L.) [es

  16. Single electron attachment and stripping cross sections for relativistic heavy ions

    International Nuclear Information System (INIS)

    Crawford, H.J.

    1979-06-01

    The results of a Bevalac experiment to measure the single electron attachment and stripping cross sections for relativistic (0.5 1 , and fully stripped, N 0 , ion beams emerging from the targets. Separate counters measured the number of ions in each charge state. The ratios N 1 /N 0 for different target thicknesses were fit to a simple growth curve to yield electron attachment and stripping cross sections. The data are compared to relativistic extrapolations of available theories. Clear evidence for two separate attachment processes, radiative and non-radiative, is found. Data are compared to a recently improved formulation for the stripping cross sections

  17. Andrei Andreevich Bolibrukh's works on the analytic theory of differential equations

    Science.gov (United States)

    Anosov, Dmitry V.; Leksin, Vladimir P.

    2011-02-01

    This paper contains an account of A.A. Bolibrukh's results obtained in the new directions of research that arose in the analytic theory of differential equations as a consequence of his sensational counterexample to the Riemann-Hilbert problem. A survey of results of his students in developing topics first considered by Bolibrukh is also presented. The main focus is on the role of the reducibility/irreducibility of systems of linear differential equations and their monodromy representations. A brief synopsis of results on the multidimensional Riemann-Hilbert problem and on isomonodromic deformations of Fuchsian systems is presented, and the main methods in the modern analytic theory of differential equations are sketched. Bibliography: 69 titles.

  18. Analytical properties of the radiance in atmospheric radiative transfer theory

    International Nuclear Information System (INIS)

    Otto, Sebastian

    2014-01-01

    It is demonstrated mathematically strictly that state density functions, as the radiance (specific intensity), exist to describe certain state properties of transported photons on microscopic and the state of the radiation field on macroscopic scale, which have independent physical meanings. Analytical properties as boundedness, continuity, differentiability and integrability of these functions to describe the photon transport are discussed. It is shown that the density functions may be derived based on the assumption of photons as real particles of non-zero and finite size, independently of usual electrodynamics, and certain historically postulated functional relationships between them were proved, that is, these functions can be derived mathematically strictly and consistently within the framework of the theory of the phenomenological radiative transfer if one takes the theory seriously by really assuming photons as particles. In this sense these functions may be treated as fundamental physical quantities within the scope of this theory, if one considers the possibility of the existence of photons. -- Highlights: • Proof of existence of the radiance within the scope of the theory of atmospheric radiative transfer. • Proof of relations between the photon number and photon energy density function and the radiance. • Strictly mathematical derivation of the analytical properties of these state density functions

  19. Analytic theory for the selection of 2-D needle crystal at arbitrary Peclet number

    Science.gov (United States)

    Tanveer, Saleh

    1989-01-01

    An accurate analytic theory is presented for the velocity selection of a two-dimensional needle crystal for arbitrary Peclet number for small values of the surface tension parameter. The velocity selection is caused by the effect of transcendentally small terms which are determined by analytic continuation to the complex plane and analysis of nonlinear equations. The work supports the general conclusion of previous small Peclet number analytical results of other investigators, though there are some discrepancies in details. It also addresses questions raised on the validity of selection theory owing to assumptions made on shape corrections at large distances from the tip.

  20. Linear response theory an analytic-algebraic approach

    CERN Document Server

    De Nittis, Giuseppe

    2017-01-01

    This book presents a modern and systematic approach to Linear Response Theory (LRT) by combining analytic and algebraic ideas. LRT is a tool to study systems that are driven out of equilibrium by external perturbations. In particular the reader is provided with a new and robust tool to implement LRT for a wide array of systems. The proposed formalism in fact applies to periodic and random systems in the discrete and the continuum. After a short introduction describing the structure of the book, its aim and motivation, the basic elements of the theory are presented in chapter 2. The mathematical framework of the theory is outlined in chapters 3–5: the relevant von Neumann algebras, noncommutative $L^p$- and Sobolev spaces are introduced; their construction is then made explicit for common physical systems; the notion of isopectral perturbations and the associated dynamics are studied. Chapter 6 is dedicated to the main results, proofs of the Kubo and Kubo-Streda formulas. The book closes with a chapter about...

  1. Analytic function theory of several variables elements of Oka’s coherence

    CERN Document Server

    Noguchi, Junjiro

    2016-01-01

    The purpose of this book is to present the classical analytic function theory of several variables as a standard subject in a course of mathematics after learning the elementary materials (sets, general topology, algebra, one complex variable). This includes the essential parts of Grauert–Remmert's two volumes, GL227(236) (Theory of Stein spaces) and GL265 (Coherent analytic sheaves) with a lowering of the level for novice graduate students (here, Grauert's direct image theorem is limited to the case of finite maps). The core of the theory is "Oka's Coherence", found and proved by Kiyoshi Oka. It is indispensable, not only in the study of complex analysis and complex geometry, but also in a large area of modern mathematics. In this book, just after an introductory chapter on holomorphic functions (Chap. 1), we prove Oka's First Coherence Theorem for holomorphic functions in Chap. 2. This defines a unique character of the book compared with other books on this subject, in which the notion of coherence appear...

  2. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).

    Science.gov (United States)

    Dimeski, G; Jones, B W; Tilley, V; Greenslade, M N; Russell, A W

    2010-07-01

    Both Roche and Abbott have released new glucose meter strips. They supply the entire Australian hospital market. The present study compared the performance of the new strips utilizing various specimen types (capillary, venous lithium heparin whole blood, venous lithium heparin plasma and serum) and evaluated how well they comply with the International Standards Organization (ISO) 15197 criteria. The study included imprecision, patient comparison and interference studies. Participants with and without diabetes were recruited to evaluate the performance of various specimen types against the Beckman DxC800 glucose method. The strips were tested for different interferences: galactose, maltose, lactose, Icodextrin, Intragam, paracetamol, sodium, ascorbic acid, variable strip storage temperature, haematocrit, haemolysis and lipaemia. The imprecision of the two strips was approximately 5% or less, except for the Abbott strip at very low values (1.4 mmol/L), approximately 7%. In total, 78% and 84%, respectively, of the results from the finger prick capillary specimens with the Roche (Accu-Chek Performa meter) and Abbott (Optium Xceed meter) strips, not 95% or greater as recommended by the ISO guideline, were within the recommended limits compared with reference plasma estimation on laboratory analysers. Galactose, ascorbic acid, haematocrit and sodium on the Roche and ascorbic acid and haematocrit on the Abbott strip continue to interfere to a variable degree with the glucose measurement. Analytically small differences exist between the glucose meter strips. The most significant analytical difference with the strips was at low glucose levels when compared with laboratory analyses and this may be of clinical importance. The impact of some of the interferences is variable between the two strips. Individuals, health-care professionals and health-care institutions should consider these data when selecting glucose meters for the management of people with diabetes mellitus.

  3. Analyticity properties of the S-matrix: historical survey and recent results in S-matrix theory and axiomatic field theory

    International Nuclear Information System (INIS)

    Iagolnitzer, D.

    1981-02-01

    An introduction to recent works, in S-matrix theory and axiomatic field theory, on the analysis and derivation of momentum-space analyticity properties of the multiparticle S matrix is presented. It includes an historical survey, which outlines the successes but also the basic difficulties encountered in the sixties in both theories, and the evolution of the subject in the seventies

  4. Federalism. Theory and Neo-Functionalism: Elements for an analytical framework

    DEFF Research Database (Denmark)

    Dosenrode, Søren

    2010-01-01

    -McKayian way, is able to explain the cases of ‘big bang’ integration (USA, Australia, Canada), but not an ‘organic’ integration process. Neo-functionalism, on the other hand, is not able to explain this relatively fast form of integration, but it is – in its new version - able to analyze and explain......The purpose of this article is to propose a draft for an analytical frame for analyzing regional integration consisting of federalism theory and neo-functionalism. It starts out discussing the concept of regional integration setting up a stagiest model for categorizing it.Then follows an analysis...... of federalism theory and neo-functionalism. One argument of this article is to understand federalism theory as a regional integration theory. Another is to look at federalism theory as complementary to neo-functionalism when trying to explain regional integration. Federalism theory, in an extended Riker...

  5. Fractional analytic perturbation theory in Minkowski space and application to Higgs boson decay into a bb pair

    International Nuclear Information System (INIS)

    Bakulev, A. P.; Mikhailov, S. V.; Stefanis, N. G.

    2007-01-01

    We work out and discuss the Minkowski version of fractional analytic perturbation theory for QCD observables, recently developed and presented by us for the Euclidean region. The original analytic approach to QCD, initiated by Shirkovand Solovtsov, is summarized and relations to other proposals to achieve an analytic strong coupling are pointed out. The developed framework is applied to the Higgs boson decay into a bb pair, using recent results for the massless correlator of two quark scalar currents in the MS scheme.We present calculations for the decay width within the Minkowski version off ractional analytic perturbation theory including those non-power-series contributions that correspond to the O(α s 3 )-terms, also taking into account evolution effects of the running coupling and the b-quark-mass renormalization. Comparisons with previous results within standard QCD perturbation theory are performed and the differences are pointed out. The interplay between effects originating from the analyticity requirement and the analytic continuation from the spacelike to the timelike region and those due to the evolution of the heavy-quark mass is addressed, highlighting the differences from the conventional QCD perturbation theory

  6. Anodic stripping voltammetry – ASV for determination of heavy metals

    International Nuclear Information System (INIS)

    Barón-Jaimez, J; Joya, M R; Barba-Ortega, J

    2013-01-01

    Although voltammetric methods presented a number of difficulties in its early stages, nowadays ''ASV'' anodic stripping voltammetry is considered one of the most sensitive electro-analytical and suitable for trace-level determination of many metals and compounds in environmental samples, clinical and industrial. Its sensitivity is attributed to the combination of a step of pre-concentration effective together with an electrochemical advanced measurement of accumulated analyte. This paper presents an overview of the voltammetry, which includes a group of electro-analytical methods, in them the information about analyte is obtained from measurements of the current flowing in an electrochemical cell when applied a potential difference to an suitable electrode system

  7. Analytic theory for the selection of a two-dimensional needle crystal at arbitrary Peclet number

    Science.gov (United States)

    Tanveer, S.

    1989-01-01

    An accurate analytic theory is presented for the velocity selection of a two-dimensional needle crystal for arbitrary Peclet number for small values of the surface tension parameter. The velocity selection is caused by the effect of transcendentally small terms which are determined by analytic continuation to the complex plane and analysis of nonlinear equations. The work supports the general conclusion of previous small Peclet number analytical results of other investigators, though there are some discrepancies in details. It also addresses questions raised on the validity of selection theory owing to assumptions made on shape corrections at large distances from the tip.

  8. Analytical properties and behaviour of scattering amplitude at high energies in the localizable quantum field theory

    International Nuclear Information System (INIS)

    Lazur, V.Yu.; Khimich, I.V.

    1977-01-01

    Analytical properties of the elastic πN-scattering amplitude in in the cos THETA are proved in the Lehmann ellipse. The instrument for establishing analytical properties of the scattering amplitude in the cos THETA is the Jost-Lehmann-Dyson integral representation proved in terms of the localizable quantum field theory containing the strictly localizable theory and theory of moderate growth as particular cases. On this basis the Greenberg-Low restriction is obtained in frames of this class theories for the πN-scattering amplitude. This result gives a possibility to prove the ordinary dispersion relations with a finite number of subtraction in frames of the localizable quantum field theory

  9. Stripping potentiometric analysis: application to determination of metallic cations in presence of uranium

    International Nuclear Information System (INIS)

    Pereira-Ramos, J.P.; Chivot, J.; Sarantopoulos, F.; Godard, R.

    1984-01-01

    Potentiometric stripping analysis consists of a potentiostatic deposition step of trace elements and a subsequent stripping step. The trace metals are simultaneously reduced at a rotating electrode, the working electrode being a mercury film coated glassy carbon electrode; the amalgamated metals are then re-oxidized with an oxidizing agent. The analytical signal of this method is the time required for complete re-oxidation. Influence of different parameters on the analytical signal is studied by using mercury (II) ions as oxidizing agent in 5.10 -4 M H 2 SO 4 aqueous solution. Here, we point out the main characteristics of the potentiometric stripping analysis under the same experimental conditions. The reproductibility ranges are comprised between 0.5% to 1.5% and the detection limit for cadmium (II) is estimated to be 2.10 -10 M with a plating time of 300 seconds. Small quantities, as 10 -7 M Cd 2+ , Pb 2+ and Zn 2+ are simultaneously determined in presence of U (VI) ions (UO 2 2+ ) with an accuracy of 0.5% for Cd 2+ and Zn 2+ , and 4.5% for Pb 2+ . Compared to well-known electrochemical techniques, potentiometric stripping analysis appears to be a performing method for trace analysis in a wide range of media: this method permits the analysis of elements in presence of species more concentrated and being able to oxidize the trace elements [fr

  10. 360-degrees profilometry using strip-light projection coupled to Fourier phase-demodulation.

    Science.gov (United States)

    Servin, Manuel; Padilla, Moises; Garnica, Guillermo

    2016-01-11

    360 degrees (360°) digitalization of three dimensional (3D) solids using a projected light-strip is a well-established technique in academic and commercial profilometers. These profilometers project a light-strip over the digitizing solid while the solid is rotated a full revolution or 360-degrees. Then, a computer program typically extracts the centroid of this light-strip, and by triangulation one obtains the shape of the solid. Here instead of using intensity-based light-strip centroid estimation, we propose to use Fourier phase-demodulation for 360° solid digitalization. The advantage of Fourier demodulation over strip-centroid estimation is that the accuracy of phase-demodulation linearly-increases with the fringe density, while in strip-light the centroid-estimation errors are independent. Here we proposed first to construct a carrier-frequency fringe-pattern by closely adding the individual light-strip images recorded while the solid is being rotated. Next, this high-density fringe-pattern is phase-demodulated using the standard Fourier technique. To test the feasibility of this Fourier demodulation approach, we have digitized two solids with increasing topographic complexity: a Rubik's cube and a plastic model of a human-skull. According to our results, phase demodulation based on the Fourier technique is less noisy than triangulation based on centroid light-strip estimation. Moreover, Fourier demodulation also provides the amplitude of the analytic signal which is a valuable information for the visualization of surface details.

  11. Analytic nuclear scattering theories

    International Nuclear Information System (INIS)

    Di Marzio, F.; University of Melbourne, Parkville, VIC

    1999-01-01

    A wide range of nuclear reactions are examined in an analytical version of the usual distorted wave Born approximation. This new approach provides either semi analytic or fully analytic descriptions of the nuclear scattering processes. The resulting computational simplifications, when used within the limits of validity, allow very detailed tests of both nuclear interaction models as well as large basis models of nuclear structure to be performed

  12. L-strip proximity fed ga

    Directory of Open Access Journals (Sweden)

    Ashish Singh

    2014-03-01

    Full Text Available In this article, the analysis of dualband L-strip fed compact semi-circular disk microstrip patch antenna has been presented using circuit theory concept. The antenna parameters such as return loss, VSWR and radiation pattern are calculated. The effect of geometric dimensions of the proposed antenna such as length of vertical and horizontal portion of L-strip is investigated. It is found that antenna resonate at two distinct modes i.e. 1.3 GHz and 6.13 GHz for lower and upper resonance frequencies respectively. The bandwidth of the proposed antenna at lower resonance frequency is 6.61% (simulated and 10.64% (theoretical whereas at upper resonance frequency, it is 6.02% (simulated and 9.06 % (theoretical. The theoretical results are compared with IE3D simulation results as well as experimental results and they are in close agreement.

  13. Electron capture by highly stripped ions

    International Nuclear Information System (INIS)

    Greenland, P.T.

    1981-06-01

    This review describes theories of electron capture suitable for the description of rearrangement collisions between atomic hydrogen and completely stripped projectiles with charge greater than unity. The region of impact velocity considered lies between 0.05 and 3 au, which is of technological importance in fusion power devices. The semiclassical, impact parameter formalism is discussed and the use of atomic expansions at medium impact velocity is described. Experimental results for both completely and partially stripped projectiles are reviewed. The use of a molecular basis at low energy, and the role of pseudocrossings peculiar to the two centre Coulomb interaction are described. Finally, purely classical techniques, in which the electron wavefunction is represented by an ensemble of Kepler orbits are considered. The review was completed in February 1981. (author)

  14. Model for prediction of strip temperature in hot strip steel mill

    International Nuclear Information System (INIS)

    Panjkovic, Vladimir

    2007-01-01

    Proper functioning of set-up models in a hot strip steel mill requires reliable prediction of strip temperature. Temperature prediction is particularly important for accurate calculation of rolling force because of strong dependence of yield stress and strip microstructure on temperature. A comprehensive model was developed to replace an obsolete model in the Western Port hot strip mill of BlueScope Steel. The new model predicts the strip temperature evolution from the roughing mill exit to the finishing mill exit. It takes into account the radiative and convective heat losses, forced flow boiling and film boiling of water at strip surface, deformation heat in the roll gap, frictional sliding heat, heat of scale formation and the heat transfer between strip and work rolls through an oxide layer. The significance of phase transformation was also investigated. Model was tested with plant measurements and benchmarked against other models in the literature, and its performance was very good

  15. Model for prediction of strip temperature in hot strip steel mill

    Energy Technology Data Exchange (ETDEWEB)

    Panjkovic, Vladimir [BlueScope Steel, TEOB, 1 Bayview Road, Hastings Vic. 3915 (Australia)]. E-mail: Vladimir.Panjkovic@BlueScopeSteel.com

    2007-10-15

    Proper functioning of set-up models in a hot strip steel mill requires reliable prediction of strip temperature. Temperature prediction is particularly important for accurate calculation of rolling force because of strong dependence of yield stress and strip microstructure on temperature. A comprehensive model was developed to replace an obsolete model in the Western Port hot strip mill of BlueScope Steel. The new model predicts the strip temperature evolution from the roughing mill exit to the finishing mill exit. It takes into account the radiative and convective heat losses, forced flow boiling and film boiling of water at strip surface, deformation heat in the roll gap, frictional sliding heat, heat of scale formation and the heat transfer between strip and work rolls through an oxide layer. The significance of phase transformation was also investigated. Model was tested with plant measurements and benchmarked against other models in the literature, and its performance was very good.

  16. An analytical method for calculating stresses and strains of ATF cladding based on thick walled theory

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun; Kim, Hak Sung [Hanyang University, Seoul (Korea, Republic of); Kim, Hyo Chan; Yang, Yong Sik; In, Wang kee [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this paper, an analytical method based on thick walled theory has been studied to calculate stress and strain of ATF cladding. In order to prescribe boundary conditions of the analytical method, two algorithms were employed which are called subroutine 'Cladf' and 'Couple' of FRACAS, respectively. To evaluate the developed method, equivalent model using finite element method was established and stress components of the method were compared with those of equivalent FE model. One of promising ATF concepts is the coated cladding, which take advantages such as high melting point, a high neutron economy, and low tritium permeation rate. To evaluate the mechanical behavior and performance of the coated cladding, we need to develop the specified model to simulate the ATF behaviors in the reactor. In particular, the model for simulation of stress and strain for the coated cladding should be developed because the previous model, which is 'FRACAS', is for one body model. The FRACAS module employs the analytical method based on thin walled theory. According to thin-walled theory, radial stress is defined as zero but this assumption is not suitable for ATF cladding because value of the radial stress is not negligible in the case of ATF cladding. Recently, a structural model for multi-layered ceramic cylinders based on thick-walled theory was developed. Also, FE-based numerical simulation such as BISON has been developed to evaluate fuel performance. An analytical method that calculates stress components of ATF cladding was developed in this study. Thick-walled theory was used to derive equations for calculating stress and strain. To solve for these equations, boundary and loading conditions were obtained by subroutine 'Cladf' and 'Couple' and applied to the analytical method. To evaluate the developed method, equivalent FE model was established and its results were compared to those of analytical model. Based on the

  17. Evaluation of Bearing Capacity of Strip Footing Using Random Layers Concept

    Directory of Open Access Journals (Sweden)

    Kawa Marek

    2015-09-01

    Full Text Available The paper deals with evaluation of bearing capacity of strip foundation on random purely cohesive soil. The approach proposed combines random field theory in the form of random layers with classical limit analysis and Monte Carlo simulation. For given realization of random the bearing capacity of strip footing is evaluated by employing the kinematic approach of yield design theory. The results in the form of histograms for both bearing capacity of footing as well as optimal depth of failure mechanism are obtained for different thickness of random layers. For zero and infinite thickness of random layer the values of depth of failure mechanism as well as bearing capacity assessment are derived in a closed form. Finally based on a sequence of Monte Carlo simulations the bearing capacity of strip footing corresponding to a certain probability of failure is estimated. While the mean value of the foundation bearing capacity increases with the thickness of the random layers, the ultimate load corresponding to a certain probability of failure appears to be a decreasing function of random layers thickness.

  18. Analytic calculations of hyper-Raman spectra from density functional theory hyperpolarizability gradients

    Energy Technology Data Exchange (ETDEWEB)

    Ringholm, Magnus; Ruud, Kenneth [Centre for Theoretical and Computational Chemistry, Department of Chemistry, University of Tromsø – The Arctic University of Norway, 9037 Tromsø (Norway); Bast, Radovan [Theoretical Chemistry and Biology, School of Biotechnology, Royal Institute of Technology, AlbaNova University Center, S-10691 Stockholm (Sweden); PDC Center for High Performance Computing, Royal Institute of Technology, S-10044 Stockholm (Sweden); Oggioni, Luca [Centre for Theoretical and Computational Chemistry, Department of Chemistry, University of Tromsø – The Arctic University of Norway, 9037 Tromsø (Norway); Department of Physics G. Occhialini, University of Milano Bicocca, Piazza della scienza 3, 20126 Milan (Italy); Ekström, Ulf [Centre for Theoretical and Computational Chemistry, Department of Chemistry, University of Oslo, P.O. Box 1033 Blindern, 0315 Oslo (Norway)

    2014-10-07

    We present the first analytic calculations of the geometrical gradients of the first hyperpolarizability tensors at the density-functional theory (DFT) level. We use the analytically calculated hyperpolarizability gradients to explore the importance of electron correlation effects, as described by DFT, on hyper-Raman spectra. In particular, we calculate the hyper-Raman spectra of the all-trans and 11-cis isomers of retinal at the Hartree-Fock (HF) and density-functional levels of theory, also allowing us to explore the sensitivity of the hyper-Raman spectra on the geometrical characteristics of these structurally related molecules. We show that the HF results, using B3LYP-calculated vibrational frequencies and force fields, reproduce the experimental data for all-trans-retinal well, and that electron correlation effects are of minor importance for the hyper-Raman intensities.

  19. Deciphering lead and cadmium stripping peaks for porous antimony deposited electrodes

    Directory of Open Access Journals (Sweden)

    Taimoor Aqeel Ahmad

    2016-06-01

    Full Text Available Cadmium and lead are generally taken as model heavy metal ions in water to scale the detection limit of various electrode sensors, using electrochemical sensing techniques. These ions interact with the electrochemically deposited antimony electrodes depending on the diffusion limitations. The phenomenon acts differently for the in-situ and ex-situ deposition as well as for porous and non-porous electrodes. A method has been adopted in this study to discourage the stripping and deposition of the working ions (antimony to understand the principle of heavy metal ion detection. X-ray photoelectron spectroscopy (XPS technique was used to establish the interaction between the working and dissolved ions. In addition to the distinct peaks for each analyte, researchers also observed a shoulder peak. A possible reason for the presence of this peak was provided. Different electrochemical tests were performed to ascertain the theory on the basis of the experimental observations.

  20. Backward wave oscillators with rippled wall resonators: Analytic theory and numerical simulation

    International Nuclear Information System (INIS)

    Swegle, J.A.; Poukey, J.W.

    1985-01-01

    The 3-D analytic theory is based on the approximation that the device is infinitely long. In the absence of an electron beam, the theory is exact and allows us to compute the dispersion characteristics of the cold structure. With the inclusion of a thin electron beam, we can compute the growth rates resulting from the interaction between a waveguide mode of the structure and the slower space charge wave on the beam. In the limit of low beam currents, the full dispersion relation based on an electromagnetic analysis can be placed in correspondence with the circuit theory of Pierce. Numerical simulations permit us to explore the saturated, large amplitude operating regime for TM axisymmetric modes. The scaling of operating frequency, peak power, and operating efficiency with beam and resonator parameters is examined. The analytic theory indicates that growth rates are largest for the TM 01 modes and decrease with both the radial and azimuthal mode numbers. Another interesting trend is that for a fixed cathode voltage and slow wave structure, growth rates peak for a beam current below the space charge limiting value and decrease for both larger and smaller currents. The simulations show waves that grow from noise without any input signal, so that the system functions as an oscillator. The TM 01 mode predominates in all simulations. While a minimum device length is required for the start of oscillations, it appears that if the slow wave structure is too long, output power is decreased by a transfer of wave energy back to the electrons. Comparisons have been made between the analytical and numerical results, as well as with experimental data obtained at Sandia National Laboratories

  1. Analytical study of Yang–Mills theory in the infrared from first principles

    Energy Technology Data Exchange (ETDEWEB)

    Siringo, Fabio, E-mail: fabio.siringo@ct.infn.it

    2016-06-15

    Pure Yang–Mills SU(N) theory is studied in the Landau gauge and four dimensional space. While leaving the original Lagrangian unmodified, a double perturbative expansion is devised, based on a massive free-particle propagator. In dimensional regularization, all diverging mass terms cancel exactly in the double expansion, without the need to include mass counterterms that would spoil the symmetry of the Lagrangian. No free parameters are included that were not in the original theory, yielding a fully analytical approach from first principles. The expansion is safe in the infrared and is equivalent to the standard perturbation theory in the UV. At one-loop, explicit analytical expressions are given for the propagators and the running coupling and are found in excellent agreement with the data of lattice simulations. A universal scaling property is predicted for the inverse propagators and shown to be satisfied by the lattice data. Higher loops are found to be negligible in the infrared below 300 MeV where the coupling becomes small and the one-loop approximation is under full control.

  2. KRITIK SOSIAL DALAM KOMIK STRIP PAK BEI

    Directory of Open Access Journals (Sweden)

    Yudhi Novriansyah

    2016-08-01

    Full Text Available This research aimed to do interpret the marking which flange social criticism and know laboring ideology in story of Comic Strip Pak Bei. Research based on theory of structural semiotic according to Ferdinand De Saussure. Using analysis of Syntagmatic as first level of meaning to the text network and also picture, and analysis of Paradigmatic as second level of meaning or implicit meaning (connota-tion, myth, ideology Analysis done to six Comic choice edition of Strip Pak Bei period of November 2004 - Februari 2005 which tend to flange social criticism. At band of syntagmatic, result of research indicate that story theme lifted from social problems that happened in major society. The fact clear progressively when connected by Intertextual with information and texts which have preexisted. At band of Paradigmatic, social criticism tend to emerge dimly, is not transparent. Because of Comic Strip Pak Bei expand in the middle of Java cultural domination that developing myth of criticize as action menacing compatibility and orderliness of society. Story of Comic Strip Pak Bei also confirm dominant ideology in Java society culture, namely ideology of Patriarkhi and Feudalism which still go into effect until now. This prove ideology idea according to Louis Althusser which not again opposition between class, but have been owned and practiced by all social class.

  3. On Analytical Solutions of f(R) Modified Gravity Theories in FLRW Cosmologies

    Science.gov (United States)

    Domazet, Silvije; Radovanović, Voja; Simonović, Marko; Štefančić, Hrvoje

    2013-02-01

    A novel analytical method for f(R) modified theories without matter in Friedmann-Lemaitre-Robertson-Walker (FLRW) spacetimes is introduced. The equation of motion for the scale factor in terms of cosmic time is reduced to the equation for the evolution of the Ricci scalar R with the Hubble parameter H. The solution of equation of motion for actions of the form of power law in Ricci scalar R is presented with a detailed elaboration of the action quadratic in R. The reverse use of the introduced method is exemplified in finding functional forms f(R), which leads to specified scale factor functions. The analytical solutions are corroborated by numerical calculations with excellent agreement. Possible further applications to the phases of inflationary expansion and late-time acceleration as well as f(R) theories with radiation are outlined.

  4. ANALYSIS ON THE BEHAVIOR OF PRECIPITATES IN ULTRA-THIN HOT STRIP OF PLAIN LOW CARBON STEEL PRODUCED BY COMPACT STRIP PRODUCTION

    Institute of Scientific and Technical Information of China (English)

    H. Yu; Y.L. Kang; H.B. Dong; D.L. Liu; J. Fu

    2002-01-01

    This paper investigated the mechanism of precipitation and its influence upon prop-erties of ultra-thin hot strips of low carbon steel produced by CSP techniques usingexperiment and thermodynamics theory. The experimental results show that thereare lots of fine and dispersive precipitates in microstructures. By analysis, most ofaluminum nitrides are in grains, while coexisted precipitates of MnS are along grainboundaries. Coexisted precipitates compose cation-vacancy type oxides such as Al2O3in the core, while MnS is at the fringe of surface. The precipitation behavior of AlNand MnS in the hot strip is studied by thermodynamic calculation. At last, implica-tions between strengthening effect and techniques are analyzed using obtained solubilityproducts.

  5. Slip Morphology of Elastic Strips on Frictional Rigid Substrates.

    Science.gov (United States)

    Sano, Tomohiko G; Yamaguchi, Tetsuo; Wada, Hirofumi

    2017-04-28

    The morphology of an elastic strip subject to vertical compressive stress on a frictional rigid substrate is investigated by a combination of theory and experiment. We find a rich variety of morphologies, which-when the bending elasticity dominates over the effect of gravity-are classified into three distinct types of states: pinned, partially slipped, and completely slipped, depending on the magnitude of the vertical strain and the coefficient of static friction. We develop a theory of elastica under mixed clamped-hinged boundary conditions combined with the Coulomb-Amontons friction law and find excellent quantitative agreement with simulations and controlled physical experiments. We also discuss the effect of gravity in order to bridge the difference in the qualitative behaviors of stiff strips and flexible strings or ropes. Our study thus complements recent work on elastic rope coiling and takes a significant step towards establishing a unified understanding of how a thin elastic object interacts vertically with a solid surface.

  6. Electromagnetic wave theory for boundary-value problems an advanced course on analytical methods

    CERN Document Server

    Eom, Hyo J

    2004-01-01

    Electromagnetic wave theory is based on Maxwell's equations, and electromagnetic boundary-value problems must be solved to understand electromagnetic scattering, propagation, and radiation. Electromagnetic theory finds practical applications in wireless telecommunications and microwave engineering. This book is written as a text for a two-semester graduate course on electromagnetic wave theory. As such, Electromagnetic Wave Theory for Boundary-Value Problems is intended to help students enhance analytic skills by solving pertinent boundary-value problems. In particular, the techniques of Fourier transform, mode matching, and residue calculus are utilized to solve some canonical scattering and radiation problems.

  7. You're a good structure, Charlie Brown: the distribution of narrative categories in comic strips.

    Science.gov (United States)

    Cohn, Neil

    2014-01-01

    Cohn's (2013) theory of "Visual Narrative Grammar" argues that sequential images take on categorical roles in a narrative structure, which organizes them into hierarchic constituents analogous to the organization of syntactic categories in sentences. This theory proposes that narrative categories, like syntactic categories, can be identified through diagnostic tests that reveal tendencies for their distribution throughout a sequence. This paper describes four experiments testing these diagnostics to provide support for the validity of these narrative categories. In Experiment 1, participants reconstructed unordered panels of a comic strip into an order that makes sense. Experiment 2 measured viewing times to panels in sequences where the order of panels was reversed. In Experiment 3, participants again reconstructed strips but also deleted a panel from the sequence. Finally, in Experiment 4 participants identified where a panel had been deleted from a comic strip and rated that strip's coherence. Overall, categories had consistent distributional tendencies within experiments and complementary tendencies across experiments. These results point toward an interaction between categorical roles and a global narrative structure. © 2014 Cognitive Science Society, Inc.

  8. Analytical theory of Doppler reflectometry in slab plasma model

    Energy Technology Data Exchange (ETDEWEB)

    Gusakov, E.Z.; Surkov, A.V. [Ioffe Institute, Politekhnicheskaya 26, St. Petersburg (Russian Federation)

    2004-07-01

    Doppler reflectometry is considered in slab plasma model in the frameworks of analytical theory. The diagnostics locality is analyzed for both regimes: linear and nonlinear in turbulence amplitude. The toroidal antenna focusing of probing beam to the cut-off is proposed and discussed as a method to increase diagnostics spatial resolution. It is shown that even in the case of nonlinear regime of multiple scattering, the diagnostics can be used for an estimation (with certain accuracy) of plasma poloidal rotation profile. (authors)

  9. Energy-Efficient Bioalcohol Recovery by Gel Stripping

    Science.gov (United States)

    Godbole, Rutvik; Ma, Lan; Hedden, Ronald

    2014-03-01

    Design of energy-efficient processes for recovering butanol and ethanol from dilute fermentations is a key challenge facing the biofuels industry due to the high energy consumption of traditional multi-stage distillation processes. Gel stripping is an alternative purification process by which a dilute alcohol is stripped from the fermentation product by passing it through a packed bed containing particles of a selectively absorbent polymeric gel material. The gel must be selective for the alcohol, while swelling to a reasonable degree in dilute alcohol-water mixtures. To accelerate materials optimization, a combinatorial approach is taken to screen a matrix of copolymer gels having orthogonal gradients in crosslinker concentration and hydrophilicity. Using a combination of swelling in pure solvents, the selectivity and distribution coefficients of alcohols in the gels can be predicted based upon multi-component extensions of Flory-Rehner theory. Predictions can be validated by measuring swelling in water/alcohol mixtures and conducting h HPLC analysis of the external liquid. 95% + removal of butanol from dilute aqueous solutions has been demonstrated, and a mathematical model of the unsteady-state gel stripping process has been developed. NSF CMMI Award 1335082.

  10. Real analytic solutions for marginal deformations in open superstring field theory

    International Nuclear Information System (INIS)

    Okawa, Yuji

    2007-01-01

    We construct analytic solutions for marginal deformations satisfying the reality condition in open superstring field theory formulated by Berkovits when operator products made of the marginal operator and the associated superconformal primary field are regular. Our strategy is based on the recent observation by Erler that the problem of finding solutions for marginal deformations in open superstring field theory can be reduced to a problem in the bosonic theory of finding a finite gauge parameter for a certain pure-gauge configuration labeled by the parameter of the marginal deformation. We find a gauge transformation generated by a real gauge parameter which infinitesimally changes the deformation parameter and construct a finite gauge parameter by its path-ordered exponential. The resulting solution satisfies the reality condition by construction

  11. Real analytic solutions for marginal deformations in open superstring field theory

    International Nuclear Information System (INIS)

    Okawa, Y.

    2007-04-01

    We construct analytic solutions for marginal deformations satisfying the reality condition in open superstring field theory formulated by Berkovits when operator products made of the marginal operator and the associated superconformal primary field are regular. Our strategy is based on the recent observation by Erler that the problem of finding solutions for marginal deformations in open superstring field theory can be reduced to a problem in the bosonic theory of finding a finite gauge parameter for a certain pure-gauge configuration labeled by the parameter of the marginal deformation. We find a gauge transformation generated by a real gauge parameter which infinitesimally changes the deformation parameter and construct a finite gauge parameter by its path-ordered exponential. The resulting solution satisfies the reality condition by construction. (orig.)

  12. Stress-strain state of the elastic strip with nearly rectangular cross section

    Science.gov (United States)

    Minaeva, N. V.

    2018-03-01

    The article considers behavior of elastic strip in the framework of plane strain under compression. Conditions are formulated in integral form on the boundaries where the forces are imposed. All the boundary conditions are imposed on the boundary of the body in the strained state, which is necessary for investigating the continuous dependence of the solution to the corresponding task on the functions describing the difference between the shape of cross-section of the strip and a rectangle. The study of the analyticity of the problem solution with respect to small near zero parameters is carried out. The solution is found by perturbation method up to the first order of terms.

  13. Pressure and wall shear stress in blood hammer - Analytical theory.

    Science.gov (United States)

    Mei, Chiang C; Jing, Haixiao

    2016-10-01

    We describe an analytical theory of blood hammer in a long and stiffened artery due to sudden blockage. Based on the model of a viscous fluid in laminar flow, we derive explicit expressions of oscillatory pressure and wall shear stress. To examine the effects on local plaque formation we also allow the blood vessel radius to be slightly nonuniform. Without resorting to discrete computation, the asymptotic method of multiple scales is utilized to deal with the sharp contrast of time scales. The effects of plaque and blocking time on blood pressure and wall shear stress are studied. The theory is validated by comparison with existing water hammer experiments. Copyright © 2016. Published by Elsevier Inc.

  14. Analytic theory of curvature effects for wave problems with general boundary conditions

    DEFF Research Database (Denmark)

    Willatzen, Morten; Gravesen, Jens; Voon, L. C. Lew Yan

    2010-01-01

    A formalism based on a combination of differential geometry and perturbation theory is used to obtain analytic expressions for confined eigenmode changes due to general curvature effects. In cases of circular-shaped and helix-shaped structures, where alternative analytic solutions can be found......, the perturbative solution is shown to yield the same result. The present technique allows the generalization of earlier results to arbitrary boundary conditions. The power of the method is illustrated using examples based on Maxwell’s and Schrödinger’s equations for applications in photonics and nanoelectronics....

  15. Some questions of using coding theory and analytical calculation methods on computers

    International Nuclear Information System (INIS)

    Nikityuk, N.M.

    1987-01-01

    Main results of investigations devoted to the application of theory and practice of correcting codes are presented. These results are used to create very fast units for the selection of events registered in multichannel detectors of nuclear particles. Using this theory and analytical computing calculations, practically new combination devices, for example, parallel encoders, have been developed. Questions concerning the creation of a new algorithm for the calculation of digital functions by computers and problems of devising universal, dynamically reprogrammable logic modules are discussed

  16. Algebraic and analyticity properties of the n-point function in quantum field theory

    International Nuclear Information System (INIS)

    Bros, Jacques

    1970-01-01

    The general theory of quantized fields (axiomatic approach) is investigated. A systematic study of the algebraic properties of all the Green functions of a local field, which generalize the ordinary retarded and advanced functions, is presented. The notion emerges of a primitive analyticity domain of the n-point function, and of the existence of auxiliary analytic functions into which the various Green functions can be decomposed. Certain processes of analytic completion are described, and then applied to enlarging the primitive domain, particularly for the case n = 4; among the results the crossing property for all scattering amplitudes which involve two incoming and two outgoing particles is proved. (author) [fr

  17. Convergence and analytic properties of manifestly finite perturbation theory

    International Nuclear Information System (INIS)

    Mtingwa, S.K.

    1979-01-01

    The author discusses more carefully the ultraviolet convergence properties of Feynman diagrams in recently proposed manifestly finite perturbation expansions. Speccifically, he refines one of the constraints on the γ's-the noncanonical dimensions-such that, when satisfied, any general product-type interaction of massive scalar, fermion and vector fields yields finite perturbation expansions requiring no conventional renormalization procedure. Moreover, the analytic properties of the Feynman integrals in the theory are discussed and concluded with remarks on the necessity of a modified Kaellen-Lehmann representation

  18. Quantitative comparison of 3 enamel-stripping devices in vitro: how precisely can we strip teeth?

    Science.gov (United States)

    Johner, Alexander Marc; Pandis, Nikolaos; Dudic, Alexander; Kiliaridis, Stavros

    2013-04-01

    In this in-vitro study, we aimed to investigate the predictability of the expected amount of stripping using 3 common stripping devices on premolars. One hundred eighty extracted premolars were mounted and aligned in silicone. Tooth mobility was tested with Periotest (Medizintechnik Gulden, Modautal, Germany) (8.3 ± 2.8 units). The selected methods for interproximal enamel reduction were hand-pulled strips (Horico, Hapf Ringleb & Company, Berlin, Germany), oscillating segmental disks (O-drive-OD 30; KaVo Dental, Biberach, Germany), and motor-driven abrasive strips (Orthofile; SDC Switzerland, Lugano-Grancia, Switzerland). With each device, the operator intended to strip 0.1, 0.2, 0.3, or 0.4 mm on the mesial side of 15 teeth. The teeth were scanned before and after stripping with a 3-dimensional laser scanner. Superposition and measurement of stripped enamel on the most mesial point of the tooth were conducted with Viewbox software (dHal Software, Kifissia, Greece). The Wilcoxon signed rank test and the Kruskal-Wallis test were applied; statistical significance was set at alpha ≤ 0.05. Large variations between the intended and the actual amounts of stripped enamel, and between stripping procedures, were observed. Significant differences were found at 0.1 mm of intended stripping (P ≤ 0.05) for the hand-pulled method and at 0.4 mm of intended stripping (P ≤ 0.001 to P = 0.05) for all methods. For all scenarios of enamel reduction, the actual amount of stripping was less than the predetermined and expected amount of stripping. The Kruskal-Wallis analysis showed no significant differences between the 3 methods. There were variations in the stripped amounts of enamel, and the stripping technique did not appear to be a significant predictor of the actual amount of enamel reduction. In most cases, actual stripping was less than the intended amount of enamel reduction. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights

  19. Trapping of antimony and bismuth hydrides on a molybdenum-foil strip

    Czech Academy of Sciences Publication Activity Database

    Krejčí, Pavel; Dočekal, Bohumil

    2005-01-01

    Roč. 99, S (2005), s148-s149 ISSN 0009-2770. [Meeting on Chemistry and Life /3./. Brno, 20.09.2005-22.09.2005] R&D Projects: GA AV ČR IAA400310507 Institutional research plan: CEZ:AV0Z40310501 Keywords : hydride generation * hydride trapping * molybdenum-foil strip device Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.445, year: 2005

  20. An analytic approach to sunset diagrams in chiral perturbation theory: Theory and practice

    Energy Technology Data Exchange (ETDEWEB)

    Ananthanarayan, B.; Ghosh, Shayan [Indian Institute of Science, Centre for High Energy Physics, Karnataka (India); Bijnens, Johan [Lund University, Department of Astronomy and Theoretical Physics, Lund (Sweden); Hebbar, Aditya [Indian Institute of Science, Centre for High Energy Physics, Karnataka (India); University of Delaware, Department of Physics and Astronomy, Newark, DE (United States)

    2016-12-15

    We demonstrate the use of several code implementations of the Mellin-Barnes method available in the public domain to derive analytic expressions for the sunset diagrams that arise in the two-loop contribution to the pion mass and decay constant in three-flavoured chiral perturbation theory. We also provide results for all possible two mass configurations of the sunset integral, and derive a new one-dimensional integral representation for the one mass sunset integral with arbitrary external momentum. Thoroughly annotated Mathematica notebooks are provided as ancillary files in the Electronic Supplementary Material to this paper, which may serve as pedagogical supplements to the methods described in this paper. (orig.)

  1. An analytic approach to sunset diagrams in chiral perturbation theory: Theory and practice

    International Nuclear Information System (INIS)

    Ananthanarayan, B.; Ghosh, Shayan; Bijnens, Johan; Hebbar, Aditya

    2016-01-01

    We demonstrate the use of several code implementations of the Mellin-Barnes method available in the public domain to derive analytic expressions for the sunset diagrams that arise in the two-loop contribution to the pion mass and decay constant in three-flavoured chiral perturbation theory. We also provide results for all possible two mass configurations of the sunset integral, and derive a new one-dimensional integral representation for the one mass sunset integral with arbitrary external momentum. Thoroughly annotated Mathematica notebooks are provided as ancillary files in the Electronic Supplementary Material to this paper, which may serve as pedagogical supplements to the methods described in this paper. (orig.)

  2. Stripping voltammetric behavior of technetium at various chemically modified electrodes

    International Nuclear Information System (INIS)

    Dick, R.

    1990-09-01

    In monitoring of nuclear processing plants and storage facilities the necessity arises of assaying traces of the artificial radioactive element technetium. The oxidation states IV and VII are of particular interest. Stripping voltammetry is among the methods of assay which are suited for this purpose. It allows an enhanced selectivity to be achieved by preconcentration of the analyte and of an oxidation state of the analyte, respectively, at the electrode used. This specific enrichment is successful after appropriate chemical modification of the electrode through immobilization of a Tc-specific reagent. When various approaches of chemical modification of a glassy carbon electrode were examined, the tetraphenylarsonium chloride extractant, which is highly selective with respect to technetium, proved to be the best suited reagent, capable of fixation both by ionic and by covalent bonding on an electrodeposited polymer film. For ionic immobilization the reagent was reacted to m-sulfophenyltriphenyl arsonium and then bound to a copolymer of vinylferrocene and vinylpyridine, which had been provided with cations. It was possible to enrich Tc(VII) at such an electrode and to determine it by stripping voltammetry down to a concentration of 1x10 -8 M after 5 minutes enrichment time. (orig./EF) [de

  3. Development of analytical theory of the physical libration for a two-layer Moon

    Science.gov (United States)

    Petrova, Natalia; Barkin, Yurii; Gusev, Alexander; Ivanova, Tamara

    2010-05-01

    Investigation is being carried out in the frame of Russian-Japanese grant and directed onto providing of the future observations in the frame of the ILOM-project which is planned onto the end of the second decade. The analytical theory presents both scientific interest in its own right and can be useful as a base for the lunar annual in a future, as a clue to lunar interiors and to processes inside the lunar body. A comparison of the libration's analytical theory with new observations will allow to refine the parameters of lunar interiors: an existence or absence of a core, its size, composition and state of aggregation, Love numbers, qualitative parameter Q, etc. Contrary to the usual application of numerical libration models for analyses of observations, the analytical model is able to predict the new harmonics, early unknown and not observed (owing to the insufficient accuracy of observations) in libration's series of observations. As part of the investigation the following results were achieved. Development of the analytical theory of the Lunar Physical Libration (LPhL) were performed using the Poisson Series Processor (PSP). The base solution is realized for the 'main problem' of the LPhL in view of 4-th harmonic of selenopotential. Data on a dynamical figure of the Moon are incorporated in the theory on the basis of new observations of the Lunar gravitational field, received in a frame of space projects Clementine (1994, NASA), Lunar Prospector (1999, NASA) and the SELENE (2007 - 2009, Japan). On the basis of the constructed theory the following actions were done: 1) analyses of the present dynamical models; 2) modeling of stars trajectories in the field of view of the future optical telescope, which is planned to be placed on one of the Lunar poles in the second stage of the Japanese project SELENE-B - ILOM. Results of modeling have shown opportunities of determination of LPhL-parameters with the desirable accuracy 0.001 arc seconds planned in the ILOM

  4. Varicose vein stripping

    Science.gov (United States)

    ... stripping; Venous reflux - vein stripping; Venous ulcer - veins Patient Instructions Surgical wound care - open Varicose veins - what to ask your doctor Images Circulatory system References American Family Physician. Management of varicose veins. www.aafp.org/afp/2008/ ...

  5. Adler function for light quarks in analytic perturbation theory

    International Nuclear Information System (INIS)

    Milton, K. A.; Solovtsov, I. L.; Solovtsova, O. P.

    2001-01-01

    The method of analytic perturbation theory, which avoids the problem of ghost-pole-type singularities and gives a self-consistent description of both spacelike and timelike regions, is applied to describe the 'light' Adler function corresponding to the nonstrange vector channel of the inclusive decay of the τ lepton. The role of threshold effects is investigated. The behavior of the quark-antiquark system near threshold is described by using a new relativistic resummation factor. It is shown that the method proposed leads to good agreement with the 'experimental' Adler function down to the lowest energy scale

  6. Modelling of ballistic low energy ion solid interaction - conventional analytic theories versus computer simulations

    International Nuclear Information System (INIS)

    Littmark, U.

    1994-01-01

    The ''philosophy'' behind, and the ''psychology'' of the development from analytic theory to computer simulations in the field of atomic collisions in solids is discussed and a few examples of achievements and perspectives are given. (orig.)

  7. Testbeam evaluation of silicon strip modules for ATLAS Phase - II Strip Tracker Upgrade

    CERN Document Server

    Blue, Andrew; The ATLAS collaboration; Ai, Xiaocong; Allport, Phillip; Arling, Jan-Hendrik; Atkin, Ryan Justin; Bruni, Lucrezia Stella; Carli, Ina; Casse, Gianluigi; Chen, Liejian; Chisholm, Andrew; Cormier, Kyle James Read; Cunningham, William Reilly; Dervan, Paul; Diez Cornell, Sergio; Dolezal, Zdenek; Dopke, Jens; Dreyer, Etienne; Dreyling-Eschweiler, Jan Linus Roderik; Escobar, Carlos; Fabiani, Veronica; Fadeyev, Vitaliy; Fernandez Tejero, Javier; Fleta Corral, Maria Celeste; Gallop, Bruce; Garcia-Argos, Carlos; Greenall, Ashley; Gregor, Ingrid-Maria; Greig, Graham George; Guescini, Francesco; Hara, Kazuhiko; Hauser, Marc Manuel; Huang, Yanping; Hunter, Robert Francis Holub; Keller, John; Klein, Christoph; Kodys, Peter; Koffas, Thomas; Kotek, Zdenek; Kroll, Jiri; Kuehn, Susanne; Lee, Steven Juhyung; Liu, Yi; Lohwasser, Kristin; Meszarosova, Lucia; Mikestikova, Marcela; Mi\\~nano Moya, Mercedes; Mori, Riccardo; Moser, Brian; Nikolopoulos, Konstantinos; Peschke, Richard; Pezzullo, Giuseppe; Phillips, Peter William; Poley, Anne-luise; Queitsch-Maitland, Michaela; Ravotti, Federico; Rodriguez Rodriguez, Daniel

    2018-01-01

    The planned HL-LHC (High Luminosity LHC) is being designed to maximise the physics potential of the LHC with 10 years of operation at instantaneous luminosities of \\mbox{$7.5\\times10^{34}\\;\\mathrm{cm}^{-2}\\mathrm{s}^{-1}$}. A consequence of this increased luminosity is the expected radiation damage requiring the tracking detectors to withstand hadron equivalences to over $1x10^{15}$ 1 MeV neutron equivalent per $cm^{2}$ in the ATLAS Strips system. The silicon strip tracker exploits the concept of modularity. Fast readout electronics, deploying 130nm CMOS front-end electronics are glued on top of a silicon sensor to make a module. The radiation hard n-in-p micro-strip sensors used have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics. A series of tests were performed at the DESY-II test beam facility to investigate the detailed performance of a strip module with both 2.5cm and 5cm length strips before irradiation. The DURANTA telescope was used to obtain a pointing...

  8. Anodic stripping voltammetry of mercury, zinc, cadmium, and lead in a rice farm ecosystem

    International Nuclear Information System (INIS)

    Del Mundo, F.R.; Vicente-Beckett, V.A.

    1990-01-01

    Analytical procedures based on differential pulse anodic stripping voltammetry were developed and applied to the analysis of some trace metals in a rice farm ecosystem. A gold wire served as working electrode for the analysis of mercury in 0.1M HNO 3 ; a hanging mercury drop electrode was used for the simultaneous analyses of zinc, cadmium, and lead in 0.1M sodium acetate buffer (pH 4.5). Mercury was pre-concentrated for five minutes at + 0.20 V vs SCE. The area of the anodic stripping peaks varied linearly over the concentration range 3x10 -10 -2x10 -8 M Hg(II); the limit of detection was 0.06 ppb or 3x10 -10 M Hg(II). The simultaneous analytical method involved pre-electrolysis at -1.2 V vs SCE for ten minutes. The heights of the individual anodic stripping peaks varied linearly with concentration in a mixture of the ions over the concentration range 0.020-0.10 ppm for each ion; the limits of detection were 0.004 ppm, 0.01 ppm, and 0.01 ppm for Cd, Pb, Zn, respectively. The developed procedures were used to determine the baseline levels of these metals in soil, water, and rice plant samples from a one-hectare traditional rice farm in San Pedro, Laguna. (auth.). 26 refs.; 4 tabs.; 6 figs

  9. DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR DETERMINATION OF SOME HEAVY METALS IN URANIUM

    Directory of Open Access Journals (Sweden)

    Saryati Saryati

    2010-06-01

    Full Text Available The direct determination of some metals impurity in uranium by using differential pulse anodic stripping voltammetry (DPASV method at a hanging mercury drop electrode and in a carbonate buffer media was developed. It was found that the carbonate buffer show the strongest affinity for uranium and gives the best separation between the DPASV peaks of heavy metals impurities. The carbonate concentration markedly affects the oxidation and reduction the major and the minor constituents of the uranium samples. In 0.1 M carbonate buffer solution pH 10, copper, bismuth, thalium, lead, cadmium, zinc, could be determined without the removal of the uranium matrix. Recovery and relative standard deviation (RSD of this method was in the range of 174% - 85.2% for recovery and 36.8% - 1.2% for RSD. The larger error of analytical result was obtained for Zn at low concentration. In general, the analytic results error and RSD decreased with increasing metals concentration.   Keywords: heavy metal determination, differential pulse anodic stripping voltammetry, uranium

  10. SIRIUS - A one-dimensional multigroup analytic nodal diffusion theory code

    Energy Technology Data Exchange (ETDEWEB)

    Forslund, P. [Westinghouse Atom AB, Vaesteraas (Sweden)

    2000-09-01

    In order to evaluate relative merits of some proposed intranodal cross sections models, a computer code called Sirius has been developed. Sirius is a one-dimensional, multigroup analytic nodal diffusion theory code with microscopic depletion capability. Sirius provides the possibility of performing a spatial homogenization and energy collapsing of cross sections. In addition a so called pin power reconstruction method is available for the purpose of reconstructing 'heterogeneous' pin qualities. consequently, Sirius has the capability of performing all the calculations (incl. depletion calculations) which are an integral part of the nodal calculation procedure. In this way, an unambiguous numerical analysis of intranodal cross section models is made possible. In this report, the theory of the nodal models implemented in sirius as well as the verification of the most important features of these models are addressed.

  11. Social Cognitive Career Theory, Conscientiousness, and Work Performance: A Meta-Analytic Path Analysis

    Science.gov (United States)

    Brown, Steven D.; Lent, Robert W.; Telander, Kyle; Tramayne, Selena

    2011-01-01

    We performed a meta-analytic path analysis of an abbreviated version of social cognitive career theory's (SCCT) model of work performance (Lent, Brown, & Hackett, 1994). The model we tested included the central cognitive predictors of performance (ability, self-efficacy, performance goals), with the exception of outcome expectations. Results…

  12. Introduction to analytic and probabilistic number theory

    CERN Document Server

    Tenenbaum, Gérald

    2015-01-01

    This book provides a self contained, thorough introduction to the analytic and probabilistic methods of number theory. The prerequisites being reduced to classical contents of undergraduate courses, it offers to students and young researchers a systematic and consistent account on the subject. It is also a convenient tool for professional mathematicians, who may use it for basic references concerning many fundamental topics. Deliberately placing the methods before the results, the book will be of use beyond the particular material addressed directly. Each chapter is complemented with bibliographic notes, useful for descriptions of alternative viewpoints, and detailed exercises, often leading to research problems. This third edition of a text that has become classical offers a renewed and considerably enhanced content, being expanded by more than 50 percent. Important new developments are included, along with original points of view on many essential branches of arithmetic and an accurate perspective on up-to-...

  13. Gaming practices in everyday life. An analytical operationalization of field theory by means of practice theory

    Directory of Open Access Journals (Sweden)

    Claus Toft-Nielsen

    2015-05-01

    Full Text Available This article investigates digital game play (gaming as a specific media field (Bourdieu, 1984, p. 72, in which especially gaming capital (Consalvo, 2007 functions as a theoretical lens. We aim to analyse the specific practices that constitute and are constituted in and around gaming. This multitude of practices is theoretically qualified by the second generation of practice theorists, including (Bruchler & Postill, 2010; Reckwitz, 2002; Schatzki, 2008; Warde, 2005. The empirical data are drawn from qualitative studies of gamers and gaming practices (focus groups as well as participant observations, and function as exemplary cases that illustrate our theoretical arguments. Our purpose is to analytically operationalize field theory, by means of practice theory, to enhance our understanding of digital games as new media and the specific contexts and media practices herein.

  14. Gaming practices in everyday life. An analytical operationalization of field theory by means of practice theory

    DEFF Research Database (Denmark)

    Toft-Nielsen, Claus; Krogager, Stinne Gunder Strøm

    2015-01-01

    This article investigates digital game play (gaming) as a specific media field (Bourdieu, 1984, p. 72), in which especially gaming capital (Consalvo, 2007) functions as a theoretical lens. We aim to analyse the specific practices that constitute and are constituted in and around gaming....... This multitude of practices is theoretically qualified by the second generation of practice theorists, including (Bruchler & Postill, 2010; Reckwitz, 2002; Schatzki, 2008; Warde, 2005). The empirical data are drawn from qualitative studies of gamers and gaming practices (focus groups as well as participant...... observations), and function as exemplary cases that illustrate our theoretical arguments. Our purpose is to analytically operationalize field theory, by means of practice theory, to enhance our understanding of digital games as new media and the specific contexts and media practices herein....

  15. Analytical mechanics

    CERN Document Server

    Lemos, Nivaldo A

    2018-01-01

    Analytical mechanics is the foundation of many areas of theoretical physics including quantum theory and statistical mechanics, and has wide-ranging applications in engineering and celestial mechanics. This introduction to the basic principles and methods of analytical mechanics covers Lagrangian and Hamiltonian dynamics, rigid bodies, small oscillations, canonical transformations and Hamilton–Jacobi theory. This fully up-to-date textbook includes detailed mathematical appendices and addresses a number of advanced topics, some of them of a geometric or topological character. These include Bertrand's theorem, proof that action is least, spontaneous symmetry breakdown, constrained Hamiltonian systems, non-integrability criteria, KAM theory, classical field theory, Lyapunov functions, geometric phases and Poisson manifolds. Providing worked examples, end-of-chapter problems, and discussion of ongoing research in the field, it is suitable for advanced undergraduate students and graduate students studying analyt...

  16. THEORY OF CONCEPTUAL APPARATUS MANAGEMENT ACCOUNTING AGRICULTURAL ORGANIZATIONS ON THE BASIS OF REGISTRATION AND ANALYTICAL COMPLEX

    Directory of Open Access Journals (Sweden)

    Kobiljon Barview

    2016-02-01

    Full Text Available The article discusses the theory of management accounting unit of the agricultural organizations on the basis of accounting and analytical complex. With the development of modern economic relations of agricultural activity as a traditional sector of the economy, it is exposed to an active state regulation, which is manifested in a particular system of information and analytical support for accounting and control of enterprises in this industry. Agricultural organizations in the conditions of market economy is largely dependent on reliable information and analytical data.

  17. Anatomy Comic Strips

    Science.gov (United States)

    Park, Jin Seo; Kim, Dae Hyun; Chung, Min Suk

    2011-01-01

    Comics are powerful visual messages that convey immediate visceral meaning in ways that conventional texts often cannot. This article's authors created comic strips to teach anatomy more interestingly and effectively. Four-frame comic strips were conceptualized from a set of anatomy-related humorous stories gathered from the authors' collective…

  18. You’re a good structure, Charlie Brown: The distribution of narrative categories in comic strips

    Science.gov (United States)

    Cohn, Neil

    2014-01-01

    Cohn’s (2013) theory of “Visual Narrative Grammar” argues that sequential images take on categorical roles in a narrative structure, which organizes them into hierarchic constituents analogous to the organization of syntactic categories in sentences. This theory proposes that narrative categories, like syntactic categories, can be identified through diagnostic tests that reveal tendencies for their distribution throughout a sequence. This paper describes four experiments testing these diagnostics to provide support for the validity of these narrative categories. In Experiment 1, participants reconstructed unordered panels of a comic strip into an order that makes sense. Experiment 2 measured viewing times to panels in sequences where the order of panels was reversed. In Experiment 3 participants again reconstructed strips, but also deleted a panel from the sequence. Finally, in Experiment 4 participants identified where a panel had been deleted from a comic strip, and rated that strip’s coherence. Overall, categories had consistent distributional tendencies within experiments and complementary tendencies across experiments. These results point toward an interaction between categorical roles and a global narrative structure. PMID:24646175

  19. Numerical Test of Analytical Theories for Perpendicular Diffusion in Small Kubo Number Turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Heusen, M.; Shalchi, A., E-mail: husseinm@myumanitoba.ca, E-mail: andreasm4@yahoo.com [Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB R3T 2N2 (Canada)

    2017-04-20

    In the literature, one can find various analytical theories for perpendicular diffusion of energetic particles interacting with magnetic turbulence. Besides quasi-linear theory, there are different versions of the nonlinear guiding center (NLGC) theory and the unified nonlinear transport (UNLT) theory. For turbulence with high Kubo numbers, such as two-dimensional turbulence or noisy reduced magnetohydrodynamic turbulence, the aforementioned nonlinear theories provide similar results. For slab and small Kubo number turbulence, however, this is not the case. In the current paper, we compare different linear and nonlinear theories with each other and test-particle simulations for a noisy slab model corresponding to small Kubo number turbulence. We show that UNLT theory agrees very well with all performed test-particle simulations. In the limit of long parallel mean free paths, the perpendicular mean free path approaches asymptotically the quasi-linear limit as predicted by the UNLT theory. For short parallel mean free paths we find a Rechester and Rosenbluth type of scaling as predicted by UNLT theory as well. The original NLGC theory disagrees with all performed simulations regardless what the parallel mean free path is. The random ballistic interpretation of the NLGC theory agrees much better with the simulations, but compared to UNLT theory the agreement is inferior. We conclude that for this type of small Kubo number turbulence, only the latter theory allows for an accurate description of perpendicular diffusion.

  20. Numerical Test of Analytical Theories for Perpendicular Diffusion in Small Kubo Number Turbulence

    International Nuclear Information System (INIS)

    Heusen, M.; Shalchi, A.

    2017-01-01

    In the literature, one can find various analytical theories for perpendicular diffusion of energetic particles interacting with magnetic turbulence. Besides quasi-linear theory, there are different versions of the nonlinear guiding center (NLGC) theory and the unified nonlinear transport (UNLT) theory. For turbulence with high Kubo numbers, such as two-dimensional turbulence or noisy reduced magnetohydrodynamic turbulence, the aforementioned nonlinear theories provide similar results. For slab and small Kubo number turbulence, however, this is not the case. In the current paper, we compare different linear and nonlinear theories with each other and test-particle simulations for a noisy slab model corresponding to small Kubo number turbulence. We show that UNLT theory agrees very well with all performed test-particle simulations. In the limit of long parallel mean free paths, the perpendicular mean free path approaches asymptotically the quasi-linear limit as predicted by the UNLT theory. For short parallel mean free paths we find a Rechester and Rosenbluth type of scaling as predicted by UNLT theory as well. The original NLGC theory disagrees with all performed simulations regardless what the parallel mean free path is. The random ballistic interpretation of the NLGC theory agrees much better with the simulations, but compared to UNLT theory the agreement is inferior. We conclude that for this type of small Kubo number turbulence, only the latter theory allows for an accurate description of perpendicular diffusion.

  1. Optimisation of the conditions for stripping voltammetric analysis at liquid-liquid interfaces supported at micropore arrays: a computational simulation.

    Science.gov (United States)

    Strutwolf, Jörg; Arrigan, Damien W M

    2010-10-01

    Micropore membranes have been used to form arrays of microinterfaces between immiscible electrolyte solutions (µITIES) as a basis for the sensing of non-redox-active ions. Implementation of stripping voltammetry as a sensing method at these arrays of µITIES was applied recently to detect drugs and biomolecules at low concentrations. The present study uses computational simulation to investigate the optimum conditions for stripping voltammetric sensing at the µITIES array. In this scenario, the diffusion of ions in both the aqueous and the organic phases contributes to the sensing response. The influence of the preconcentration time, the micropore aspect ratio, the location of the microinterface within the pore, the ratio of the diffusion coefficients of the analyte ion in the organic and aqueous phases, and the pore wall angle were investigated. The simulations reveal that the accessibility of the microinterfaces during the preconcentration period should not be hampered by a recessed interface and that diffusional transport in the phase where the analyte ions are preconcentrated should be minimized. This will ensure that the ions are accumulated within the micropores close to the interface and thus be readily available for back transfer during the stripping process. On the basis of the results, an optimal combination of the examined parameters is proposed, which together improve the stripping voltammetric signal and provide an improvement in the detection limit.

  2. From basic survival analytic theory to a non-standard application

    CERN Document Server

    Zimmermann, Georg

    2017-01-01

    Georg Zimmermann provides a mathematically rigorous treatment of basic survival analytic methods. His emphasis is also placed on various questions and problems, especially with regard to life expectancy calculations arising from a particular real-life dataset on patients with epilepsy. The author shows both the step-by-step analyses of that dataset and the theory the analyses are based on. He demonstrates that one may face serious and sometimes unexpected problems, even when conducting very basic analyses. Moreover, the reader learns that a practically relevant research question may look rather simple at first sight. Nevertheless, compared to standard textbooks, a more detailed account of the theory underlying life expectancy calculations is needed in order to provide a mathematically rigorous framework. Contents Regression Models for Survival Data Model Checking Procedures Life Expectancy Target Groups Researchers, lecturers, and students in the fields of mathematics and statistics Academics and experts work...

  3. Analytic cubic and quartic force fields using density-functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Ringholm, Magnus; Gao, Bin; Thorvaldsen, Andreas J.; Ruud, Kenneth [Centre for Theoretical and Computational Chemistry (CTCC), Department of Chemistry, University of Tromsø—The Arctic University of Norway, 9037 Tromsø (Norway); Jonsson, Dan [Centre for Theoretical and Computational Chemistry (CTCC), Department of Chemistry, University of Tromsø—The Arctic University of Norway, 9037 Tromsø (Norway); High Performance Computing Group, University of Tromsø—The Arctic University of Norway, 9037 Tromsø (Norway); Bast, Radovan [Theoretical Chemistry and Biology, School of Biotechnology, Royal Institute of Technology, AlbaNova University Center, S-10691 Stockholm, Sweden and PDC Center for High Performance Computing, Royal Institute of Technology, S-10044 Stockholm (Sweden); Ekström, Ulf; Helgaker, Trygve [Center for Theoretical and Computational Chemistry (CTCC), Department of Chemistry, University of Oslo, P.O. Box 1033, Blindern, 0315 Oslo (Norway)

    2014-01-21

    We present the first analytic implementation of cubic and quartic force constants at the level of Kohn–Sham density-functional theory. The implementation is based on an open-ended formalism for the evaluation of energy derivatives in an atomic-orbital basis. The implementation relies on the availability of open-ended codes for evaluation of one- and two-electron integrals differentiated with respect to nuclear displacements as well as automatic differentiation of the exchange–correlation kernels. We use generalized second-order vibrational perturbation theory to calculate the fundamental frequencies of methane, ethane, benzene, and aniline, comparing B3LYP, BLYP, and Hartree–Fock results. The Hartree–Fock anharmonic corrections agree well with the B3LYP corrections when calculated at the B3LYP geometry and from B3LYP normal coordinates, suggesting that the inclusion of electron correlation is not essential for the reliable calculation of cubic and quartic force constants.

  4. Analytic study of nonperturbative solutions in open string field theory

    International Nuclear Information System (INIS)

    Bars, I.; Kishimoto, I.; Matsuo, Y.

    2003-01-01

    We propose an analytic framework to study the nonperturbative solutions of Witten's open string field theory. The method is based on the Moyal star formulation where the kinetic term can be split into two parts. The first one describes the spectrum of two identical half strings which are independent from each other. The second one, which we call midpoint correction, shifts the half string spectrum to that of the standard open string. We show that the nonlinear equation of motion of string field theory is exactly solvable at zeroth order in the midpoint correction. An infinite number of solutions are classified in terms of projection operators. Among them, there exists only one stable solution which is identical to the standard butterfly state. We include the effect of the midpoint correction around each exact zeroth order solution as a perturbation expansion which can be formally summed to the complete exact solution

  5. On the multiple zeros of a real analytic function with applications to the averaging theory of differential equations

    Science.gov (United States)

    García, Isaac A.; Llibre, Jaume; Maza, Susanna

    2018-06-01

    In this work we consider real analytic functions , where , Ω is a bounded open subset of , is an interval containing the origin, are parameters, and ε is a small parameter. We study the branching of the zero-set of at multiple points when the parameter ε varies. We apply the obtained results to improve the classical averaging theory for computing T-periodic solutions of λ-families of analytic T-periodic ordinary differential equations defined on , using the displacement functions defined by these equations. We call the coefficients in the Taylor expansion of in powers of ε the averaged functions. The main contribution consists in analyzing the role that have the multiple zeros of the first non-zero averaged function. The outcome is that these multiple zeros can be of two different classes depending on whether the zeros belong or not to the analytic set defined by the real variety associated to the ideal generated by the averaged functions in the Noetheriang ring of all the real analytic functions at . We bound the maximum number of branches of isolated zeros that can bifurcate from each multiple zero z 0. Sometimes these bounds depend on the cardinalities of minimal bases of the former ideal. Several examples illustrate our results and they are compared with the classical theory, branching theory and also under the light of singularity theory of smooth maps. The examples range from polynomial vector fields to Abel differential equations and perturbed linear centers.

  6. Approximate analytic theory of the multijunction grill

    International Nuclear Information System (INIS)

    Hurtak, O.; Preinhaelter, J.

    1991-03-01

    An approximate analytic theory of the general multijunction grill is developed. Omitting the evanescent modes in the subsidiary waveguides both at the junction and at the grill mouth and neglecting multiple wave reflection, simple formulae are derived for the reflection coefficient, the amplitudes of the incident and reflected waves and the spectral power density. These quantities are expressed through the basic grill parameters (the electric length of the structure and phase shift between adjacent waveguides) and two sets of reflection coefficients describing wave reflections in the subsidiary waveguides at the junction and at the plasma. Approximate expressions for these coefficients are also given. The results are compared with a numerical solution of two specific examples; they were shown to be useful for the optimization and design of multijunction grills.For the JET structure it is shown that, in the case of a dense plasma,many results can be obtained from the simple formulae for a two-waveguide multijunction grill. (author) 12 figs., 12 refs

  7. Science Comic Strips

    Science.gov (United States)

    Kim, Dae Hyun; Jang, Hae Gwon; Shin, Dong Sun; Kim, Sun-Ja; Yoo, Chang Young; Chung, Min Suk

    2012-01-01

    Science comic strips entitled Dr. Scifun were planned to promote science jobs and studies among professionals (scientists, graduate and undergraduate students) and children. To this end, the authors collected intriguing science stories as the basis of scenarios, and drew four-cut comic strips, first on paper and subsequently as computer files.…

  8. Rolling force prediction for strip casting using theoretical model and artificial intelligence

    Institute of Scientific and Technical Information of China (English)

    CAO Guang-ming; LI Cheng-gang; ZHOU Guo-ping; LIU Zhen-yu; WU Di; WANG Guo-dong; LIU Xiang-hua

    2010-01-01

    Rolling force for strip casting of 1Cr17 ferritic stainless steel was predicted using theoretical model and artificial intelligence.Solution zone was classified into two parts by kiss point position during casting strip.Navier-Stokes equation in fluid mechanics and stream function were introduced to analyze the rheological property of liquid zone and mushy zone,and deduce the analytic equation of unit compression stress distribution.The traditional hot rolling model was still used in the solid zone.Neural networks based on feedforward training algorithm in Bayesian regularization were introduced to build model for kiss point position.The results show that calculation accuracy for verification data of 94.67% is in the range of+7.0%,which indicates that the predicting accuracy of this model is very high.

  9. Vectorization and parallelization of the finite strip method for dynamic Mindlin plate problems

    Science.gov (United States)

    Chen, Hsin-Chu; He, Ai-Fang

    1993-01-01

    The finite strip method is a semi-analytical finite element process which allows for a discrete analysis of certain types of physical problems by discretizing the domain of the problem into finite strips. This method decomposes a single large problem into m smaller independent subproblems when m harmonic functions are employed, thus yielding natural parallelism at a very high level. In this paper we address vectorization and parallelization strategies for the dynamic analysis of simply-supported Mindlin plate bending problems and show how to prevent potential conflicts in memory access during the assemblage process. The vector and parallel implementations of this method and the performance results of a test problem under scalar, vector, and vector-concurrent execution modes on the Alliant FX/80 are also presented.

  10. Nuclear reactor spring strip grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Flora, B.S.

    1978-01-01

    A bimetallic grid spacer is described comprising a grid structure of zircaloy formed by intersecting striplike members which define fuel element openings for receiving fuel elements and spring strips made of Inconel positioned within the grid structure for cooperating with the fuel elements to maintain them in their desired position. A plurality of these spring strips extend longitudinally between sides of the grid structure, being locked in position by the grid retaining strips. The fuel rods, which are disposed in the fuel openings formed in the grid structure, are positioned by means of the springs associated with the spring strips and a plurality of dimples which extend from the zircaloy grid structure into the openings. In one embodiment the strips are disposed in a plurality of arrays with those spring strip arrays situated in opposing diagonal quadrants of the grid structure extending in the same direction and adjacent spring strip arrays in each half of the spacer extending in relatively perpendicular directions. Other variations of the spring strip arrangements for a particular fuel design are disclosed herein

  11. Analyticity of effective coupling and propagators in massless models of quantum field theory

    International Nuclear Information System (INIS)

    Oehme, R.

    1982-01-01

    For massless models of quantum field theory, some general theorems are proved concerning the analytic continuation of the renormalization group functions as well as the effective coupling and the propagators. Starting points are analytic properties of the effective coupling and the propagators in the momentum variable k 2 , which can be converted into analyticity of β- and γ-functions in the coupling parameter lambda. It is shown that the β-function can have branch point singularities related to stationary points of the effective coupling as a function of k 2 . The type of these singularities of β(lambda) can be determined explicitly. Examples of possible physical interest are extremal values of the effective coupling at space-like points in the momentum variable, as well as complex conjugate stationary points close to the real k 2 -axis. The latter may be related to the sudden transition between weak and strong coupling regimes of the system. Finally, for the effective coupling and for the propagators, the analytic continuation in both variables k 2 and lambda is discussed. (orig.)

  12. Noise analysis due to strip resistance in the ATLAS SCT silicon strip module

    International Nuclear Information System (INIS)

    Kipnis, I.

    1996-08-01

    The module is made out of four 6 cm x 6 cm single sided Si microstrip detectors. Two detectors are butt glued to form a 12 cm long mechanical unit and strips of the two detectors are electrically connected to form 12 cm long strips. The butt gluing is followed by a back to back attachment. The module in this note is the Rφ module where the electronics is oriented parallel to the strip direction and bonded directly to the strips. This module concept provides the maximum signal-to-noise ratio, particularly when the front-end electronics is placed near the middle rather than at the end. From the noise analysis, it is concluded that the worst-case ΔENC (far-end injection) between end- and center-tapped modules will be 120 to 210 el. rms (9 to 15%) for a non-irradiated detector and 75 to 130 el. rms (5 to 9%) for an irradiated detector, for a metal strip resistance of 10 to 20 Ω/cm

  13. Perturbation theory for Lyapunov exponents of an Anderson model on a strip

    CERN Document Server

    Schulz-Baldes, H

    2003-01-01

    It is proven that the localization length of an Anderson model on a strip of width $L$ is bounded above by $L/\\lambda^2$ for small values of the coupling constant $\\lambda$ of the disordered potential. For this purpose, a new formalism is developed in order to calculate the bottom Lyapunov exponent associated with random products of large symplectic matrices perturbatively in the coupling constant of the randomness.

  14. Area specific stripping factors for AGS. A method for extracting stripping factors from survey data

    Energy Technology Data Exchange (ETDEWEB)

    Aage, H.K.; Korsbech, U. [Technical Univ. of Denmark (Denmark)

    2006-04-15

    In order to use Airborne Gamma-ray Spectrometry (AGS) for contamination mapping, for source search etc. one must to be able to eliminate the contribution to the spectra from natural radioactivity. This in general is done by a stripping technique. The parameters for performing a stripping have until recently been measured by recording gamma spectra at special calibration sites (pads). This may be cumbersome and the parameters may not be correct when used at low gamma energies for environmental spectra. During 2000-2001 DTU tested with success a new technique for Carborne Gamma-ray Spectrometry (CGS) where the spectra from the surveyed area (or from a similar area) were used for calculating the stripping parameters. It was possible to calculate usable stripping ratios for a number of low energy windows - and weak source signals not detectable by other means were discovered with the ASS technique. In this report it is shown that the ASS technique also works for AGS data, and it has been used for recent Danish AGS tests with point sources. (Check of calibration of AGS parameters.) By using the ASS technique with the Boden data (Barents Rescue) an exercise source was detected that has not been detected by any of the teams during the exercise. The ASS technique therefore seems to be better for search for radiation anomalies than any other method known presently. The experiences also tell that although the stripping can be performed correctly at any altitude there is a variation of the stripping parameters with altitude that has not yet been quite understood. However, even with the oddly variations the stripping worked as expected. It was also observed that one might calculate a single common set of usable stripping factors for all altitudes from the entire data set i.e. some average a, b and c values. When those stripping factors were used the stripping technique still worked well. (au)

  15. Analytical benchmarks for nuclear engineering applications. Case studies in neutron transport theory

    International Nuclear Information System (INIS)

    2008-01-01

    The developers of computer codes involving neutron transport theory for nuclear engineering applications seldom apply analytical benchmarking strategies to ensure the quality of their programs. A major reason for this is the lack of analytical benchmarks and their documentation in the literature. The few such benchmarks that do exist are difficult to locate, as they are scattered throughout the neutron transport and radiative transfer literature. The motivation for this benchmark compendium, therefore, is to gather several analytical benchmarks appropriate for nuclear engineering applications under one cover. We consider the following three subject areas: neutron slowing down and thermalization without spatial dependence, one-dimensional neutron transport in infinite and finite media, and multidimensional neutron transport in a half-space and an infinite medium. Each benchmark is briefly described, followed by a detailed derivation of the analytical solution representation. Finally, a demonstration of the evaluation of the solution representation includes qualified numerical benchmark results. All accompanying computer codes are suitable for the PC computational environment and can serve as educational tools for courses in nuclear engineering. While this benchmark compilation does not contain all possible benchmarks, by any means, it does include some of the most prominent ones and should serve as a valuable reference. (author)

  16. Strip casting apparatus and method

    Science.gov (United States)

    Williams, R.S.; Baker, D.F.

    1988-09-20

    Strip casting apparatus including a molten-metal-holding container and a nozzle to deposit molten metal onto a moving chill drum to directly cast continuous metallic strip. The nozzle body includes a slot bounded between a back and a front lip. The slot width exceeds about 20 times the gap distance between the nozzle and the chill drum surface. Preferably, the slot width exceeds 0.5 inch. This method of strip casting minimizes pressure drop, insuring better metal-to-chill-drum contact which promotes heat transfer and results in a better quality metallic strip. 6 figs.

  17. Exact Analytic Result of Contact Value for the Density in a Modified Poisson-Boltzmann Theory of an Electrical Double Layer.

    Science.gov (United States)

    Lou, Ping; Lee, Jin Yong

    2009-04-14

    For a simple modified Poisson-Boltzmann (SMPB) theory, taking into account the finite ionic size, we have derived the exact analytic expression for the contact values of the difference profile of the counterion and co-ion, as well as of the sum (density) and product profiles, near a charged planar electrode that is immersed in a binary symmetric electrolyte. In the zero ionic size or dilute limit, these contact values reduce to the contact values of the Poisson-Boltzmann (PB) theory. The analytic results of the SMPB theory, for the difference, sum, and product profiles were compared with the results of the Monte-Carlo (MC) simulations [ Bhuiyan, L. B.; Outhwaite, C. W.; Henderson, D. J. Electroanal. Chem. 2007, 607, 54 ; Bhuiyan, L. B.; Henderson, D. J. Chem. Phys. 2008, 128, 117101 ], as well as of the PB theory. In general, the analytic expression of the SMPB theory gives better agreement with the MC data than the PB theory does. For the difference profile, as the electrode charge increases, the result of the PB theory departs from the MC data, but the SMPB theory still reproduces the MC data quite well, which indicates the importance of including steric effects in modeling diffuse layer properties. As for the product profile, (i) it drops to zero as the electrode charge approaches infinity; (ii) the speed of the drop increases with the ionic size, and these behaviors are in contrast with the predictions of the PB theory, where the product is identically 1.

  18. Analytic derivative couplings for spin-flip configuration interaction singles and spin-flip time-dependent density functional theory

    International Nuclear Information System (INIS)

    Zhang, Xing; Herbert, John M.

    2014-01-01

    We revisit the calculation of analytic derivative couplings for configuration interaction singles (CIS), and derive and implement these couplings for its spin-flip variant for the first time. Our algorithm is closely related to the CIS analytic energy gradient algorithm and should be straightforward to implement in any quantum chemistry code that has CIS analytic energy gradients. The additional cost of evaluating the derivative couplings is small in comparison to the cost of evaluating the gradients for the two electronic states in question. Incorporation of an exchange-correlation term provides an ad hoc extension of this formalism to time-dependent density functional theory within the Tamm-Dancoff approximation, without the need to invoke quadratic response theory or evaluate third derivatives of the exchange-correlation functional. Application to several different conical intersections in ethylene demonstrates that minimum-energy crossing points along conical seams can be located at substantially reduced cost when analytic derivative couplings are employed, as compared to use of a branching-plane updating algorithm that does not require these couplings. Application to H 3 near its D 3h geometry demonstrates that correct topology is obtained in the vicinity of a conical intersection involving a degenerate ground state

  19. Exact solution for the Poisson field in a semi-infinite strip.

    Science.gov (United States)

    Cohen, Yossi; Rothman, Daniel H

    2017-04-01

    The Poisson equation is associated with many physical processes. Yet exact analytic solutions for the two-dimensional Poisson field are scarce. Here we derive an analytic solution for the Poisson equation with constant forcing in a semi-infinite strip. We provide a method that can be used to solve the field in other intricate geometries. We show that the Poisson flux reveals an inverse square-root singularity at a tip of a slit, and identify a characteristic length scale in which a small perturbation, in a form of a new slit, is screened by the field. We suggest that this length scale expresses itself as a characteristic spacing between tips in real Poisson networks that grow in response to fluxes at tips.

  20. On the theory of direct reactions with many particle final states

    International Nuclear Information System (INIS)

    Trautmann, D.; Baur, G.

    1977-01-01

    We study the theory of direct reactions with many particle final states. First, we concentrate on the DWBA formulation of the break-up of deuterons on heavy nuclei below the Coulomb barrier. Because there are no free parameters, this permits a clean test of the theory by comparing it to the experimental data. The agreement is very good. The theory is applied to the break-up of antideuteronic atoms. Then the effect of virtual deuteron break-up on Rutherford scattering is studied. It is small, but it seems to be measurable. Also the deuteron break-up above the Coulomb barrier can be well explained theoretically. In this context, small effects are studied briefly. A semiclassical theory of the break-up process is given, which results in an intuitive picture and a fast computational method. Our theory lends itself in a natural way to the study of stripping reactions to unbound states. The relation of stripping into the continuum to elastic scattering of the transferred particle on the same target nucleus is explained. Then the connection of stripping to bound and unbound states is established. Finally various examples of stripping of uncharged and charged particles into the continuum are given to illustrate the theory. Resonance wave functions describing the transferred particle are discussed. In a conclusion an outlook for possible future developments of experiment and theory is given. (author)

  1. The Analytical Hierarchy Process

    DEFF Research Database (Denmark)

    Barfod, Michael Bruhn

    2007-01-01

    The technical note gathers the theory behind the Analytical Hierarchy Process (AHP) and present its advantages and disadvantages in practical use.......The technical note gathers the theory behind the Analytical Hierarchy Process (AHP) and present its advantages and disadvantages in practical use....

  2. The Honeycomb Strip Chamber

    International Nuclear Information System (INIS)

    Graaf, Harry van der; Buskens, Joop; Rewiersma, Paul; Koenig, Adriaan; Wijnen, Thei

    1991-06-01

    The Honeycomb Strip Chamber (HSC) is a new position sensitive detector. It consists of a stack of folded foils, forming a rigid honeycomb structure. In the centre of each hexagonal cell a wire is strung. Conducting strips on the foils, perpendicular to the wires, pick up the induced avalanche charge. Test results of a prototype show that processing the signals form three adjacent strips nearest to the track gives a spatial resolution better than 64 μm for perpendicular incident tracks. The chamber performance is only slightly affected by a magnetic field. (author). 25 refs.; 21 figs

  3. Transport ac loss in a rectangular thin strip with power-law E(J) relation

    International Nuclear Information System (INIS)

    Li, Shuo; Chen, Du-Xing; Fan, Yu; Fang, Jin

    2015-01-01

    Highlights: • Transport ac loss in a thin strip with power-law E(J) is systematically computed. • The scaled results can be accurately used for strips with any critical current and frequency. • Experiments may be unambiguously compared with modeling results at a critical frequency. - Abstract: Transport ac losses of a rectangular thin strip obeying relation E/E c =(J/J c ) n with a fixed critical current I c and n=5,10,20,30, and 40 are accurately computed at a fixed frequency f as functions of the current amplitude I m . The results may be interpolated and scaled to those at any values of I c ,f, and 5⩽n⩽40. Normalized in the same way as that in Norris’ analytical formula derived from the critical-state model and converting f to a critical frequency f c , the modeling results may be better compared with the Norris formula and experimental data. A complete set of calculated modeling data are given with necessary formulas to be easily used by experimentalists in any particular case

  4. Analytical solution for heat conduction problem in composite slab and its implementation in constructal solution for cooling of electronics

    International Nuclear Information System (INIS)

    Kuddusi, Luetfullah; Denton, Jesse C.

    2007-01-01

    The constructal solution for cooling of electronics requires solution of a fundamental heat conduction problem in a composite slab composed of a heat generating slab and a thin strip of high conductivity material that is responsible for discharging the generated heat to a heat sink located at one end of the strip. The fundamental 2D heat conduction problem is solved analytically by applying an integral transform method. The analytical solution is then employed in a constructal solution, following Bejan, for cooling of electronics. The temperature and heat flux distributions of the elemental heat generating slabs are assumed to be the same as those of the analytical solution in all the elemental volumes and the high conductivity strips distributed in the different constructs. Although the analytical solution of the fundamental 2D heat conduction problem improves the accuracy of the distributions in the elemental slabs, the results following Bejan's strategy do not affirm the accuracy of Bejan's constructal solution itself as applied to this problem of cooling of electronics. Several different strategies are possible for developing a constructal solution to this problem as is indicated

  5. Yang-Mills theories in axial and light-cone gauges, analytic regularization and Ward identities

    International Nuclear Information System (INIS)

    Lee, H.C.

    1984-12-01

    The application of the principles of generalization and analytic continuation to the regularization of divergent Feynman integrals is discussed. The technique, or analytic regularization, which is a generalization of dimensional regularization, is used to derive analytic representations for two classes of massless two-point integrals. The first class is based on the principal-value prescription and includes integrals encountered in quantum field theories in the ghost-free axial gauge (n.A=0), reducing in a special case to integrals in the light-cone gauge (n.A=0,n 2 =0). The second class is based on the Mandelstam prescription devised espcially for the light-cone gauge. For some light-cone gauge integrals the two representations are not equivalent. Both classes include as a subclass integrals in the Lorentz covariant 'zeta-gauges'. The representations are used to compute one-loop corrections to the self-energy and the three-vertex in Yang-Mills theories in the axial and light-cone gauges, showing that the two- and three-point Ward identities are satisfied; to illustrate that ultraviolet and infrared singularities, indistinguishable in dimensional regularization, can be separated analytically; and to show that certain tadpole integrals vanish because of an exact cancellation between ultraviolet and infrared singularities. In the axial gauge, the wavefunction and vertex renormalization constants, Z 3 and Z 1 , are identical, so that the β-function can be directly derived from Z 3 the result being the same as that computed in the covariant zeta-gauges. Preliminary results suggest that the light-cone gauge in the Mandelstam prescription, but not in the principal value prescription, has the same renormalization property of the axial gauge

  6. Selective chemical stripping

    Science.gov (United States)

    Malavallon, Olivier

    1995-04-01

    At the end of the 80's, some of the large European airlines expressed a wish for paint systems with improved strippability on their aircraft, allowing the possibility to strip down to the primer without altering it, using 'mild' chemical strippers based on methylene chloride. These improvements were initially intended to reduce costs and stripping cycle times while facilitating rapid repainting, and this without the need to change the conventionally used industrial facilities. The level of in-service performance of these paint systems was to be the same as the previous ones. Requirements related to hygiene safety and the environment were added to these initial requirements. To meet customers' expectations, Aerospatiale, within the Airbus Industry GIE, formed a work group. This group was given the task of specifying, following up the elaboration and qualifying the paint systems allowing requirements to be met, in relation with the paint suppliers and the airlines. The analysis made in this report showed the interest of transferring as far upstream as possible (to paint conception level) most of the technical constraints related to stripping. Thus, the concept retained for the paint system, allowing selective chemical stripping, is a 3-coat system with characteristics as near as possible to the previously used paints.

  7. Charge collection in silicon strip detectors

    International Nuclear Information System (INIS)

    Kraner, H.W.; Beuttenmuller, R.; Ludlam, T.; Hanson, A.L.; Jones, K.W.; Radeka, V.; Heijne, E.H.M.

    1982-11-01

    The use of position sensitive silicon detectors as very high resolution tracking devices in high energy physics experiments has been a subject of intense development over the past few years. Typical applications call for the detection of minimum ionizing particles with position measurement accuracy of 10 μm in each detector plane. The most straightforward detector geometry is that in which one of the collecting electrodes is subdivided into closely spaced strips, giving a high degree of segmentation in one coordinate. Each strip may be read out as a separate detection element, or, alternatively, resistive and/or capacitive coupling between adjacent strips may be exploited to interpolate the position via charge division measrurements. With readout techniques that couple several strips, the numer of readout channels can, in principle, be reduced by large factors without sacrificing the intrinsic position accuracy. The testing of individual strip properties and charge division between strips has been carried out with minimum ionizing particles or beams for the most part except in one case which used alphs particless scans. This paper describes the use of a highly collimated MeV proton beam for studies of the position sensing properties of representative one dimensional strip detectors

  8. Cryptographic applications of analytic number theory complexity lower bounds and pseudorandomness

    CERN Document Server

    2003-01-01

    The book introduces new ways of using analytic number theory in cryptography and related areas, such as complexity theory and pseudorandom number generation. Key topics and features: - various lower bounds on the complexity of some number theoretic and cryptographic problems, associated with classical schemes such as RSA, Diffie-Hellman, DSA as well as with relatively new schemes like XTR and NTRU - a series of very recent results about certain important characteristics (period, distribution, linear complexity) of several commonly used pseudorandom number generators, such as the RSA generator, Blum-Blum-Shub generator, Naor-Reingold generator, inversive generator, and others - one of the principal tools is bounds of exponential sums, which are combined with other number theoretic methods such as lattice reduction and sieving - a number of open problems of different level of difficulty and proposals for further research - an extensive and up-to-date bibliography Cryptographers and number theorists will find th...

  9. Parallel superconducting strip-line detectors: reset behaviour in the single-strip switch regime

    International Nuclear Information System (INIS)

    Casaburi, A; Heath, R M; Tanner, M G; Hadfield, R H; Cristiano, R; Ejrnaes, M; Nappi, C

    2014-01-01

    Superconducting strip-line detectors (SSLDs) are an important emerging technology for the detection of single molecules in time-of-flight mass spectrometry (TOF-MS). We present an experimental investigation of a SSLD laid out in a parallel configuration, designed to address selected single strip-lines operating in the single-strip switch regime. Fast laser pulses were tightly focused onto the device, allowing controllable nucleation of a resistive region at a specific location and study of the subsequent device response dynamics. We observed that in this regime, although the strip-line returns to the superconducting state after triggering, no effective recovery of the bias current occurs, in qualitative agreement with a phenomenological circuit simulation that we performed. Moreover, from theoretical considerations and by looking at the experimental pulse amplitude distribution histogram, we have the first confirmation of the fact that the phenomenological London model governs the current redistribution in these large area devices also after detection events. (paper)

  10. Sensitive and stable monitoring of lead and cadmium in seawater using screen-printed electrode and electrochemical stripping analysis

    International Nuclear Information System (INIS)

    Gueell, Raquel; Aragay, Gemma; Fontas, Claudia; Antico, Enriqueta; Merkoci, Arben

    2008-01-01

    Sensitive and stable monitoring of heavy metals in seawater using screen-printed electrodes (SPE) is presented. The analytical performance of SPE coupled with square wave anodic stripping voltammetry (SWASV) for the simultaneous determination of Pb and Cd in seawater samples, in the low μg L -1 range, is evaluated. The stripping response for the heavy metals following 2 min deposition was linear over the concentration range examined (10-2000 μg L -1 ) with detection limits of 1.8 and 2.9 μg L -1 for Pb and Cd, respectively. The accuracy of the method was validated by analyzing metal contents in different spiked seawater samples and comparing these results to those obtained with the well-established anodic stripping voltammetry using the hanging mercury drop electrode. Moreover, a certified reference material was also used and the results obtained were satisfactory

  11. Analytic derivatives for perturbatively corrected ''double hybrid'' density functionals: Theory, implementation, and applications

    International Nuclear Information System (INIS)

    Neese, Frank; Schwabe, Tobias; Grimme, Stefan

    2007-01-01

    A recently proposed new family of density functionals [S. Grimme, J. Chem. Phys. 124, 34108 (2006)] adds a fraction of nonlocal correlation as a new ingredient to density functional theory (DFT). This fractional correlation energy is calculated at the level of second-order many-body perturbation theory (PT2) and replaces some of the semilocal DFT correlation of standard hybrid DFT methods. The new ''double hybrid'' functionals (termed, e.g., B2-PLYP) contain only two empirical parameters that have been adjusted in thermochemical calculations on parts of the G2/3 benchmark set. The methods have provided the lowest errors ever obtained by any DFT method for the full G3 set of molecules. In this work, the applicability of the new functionals is extended to the exploration of potential energy surfaces with analytic gradients. The theory of the analytic gradient largely follows the standard theory of PT2 gradients with some additional subtleties due to the presence of the exchange-correlation terms in the self-consistent field operator. An implementation is reported for closed-shell as well as spin-unrestricted reference determinants. Furthermore, the implementation includes external point charge fields and also accommodates continuum solvation models at the level of the conductor like screening model. The density fitting resolution of the identity (RI) approximation can be applied to the evaluation of the PT2 part with large gains in computational efficiency. For systems with ∼500-600 basis functions the evaluation of the double hybrid gradient is approximately four times more expensive than the calculation of the standard hybrid DFT gradient. Extensive test calculations are provided for main group elements and transition metal containing species. The results reveal that the B2-PLYP functional provides excellent molecular geometries that are superior compared to those from standard DFT and MP2

  12. On solution of the integral equations for the potential problems of two circular-strips

    Directory of Open Access Journals (Sweden)

    C. Sampath

    1988-01-01

    Dirichlet and Newmann boundary value problems of two equal infinite coaxial circular strips in various branches of potential theory. For illustration, these solutions are applied to solve some boundary value problems in electrostatics, hydrodynamics, and expressions for the physical quantities of interest are derived.

  13. Adsorptive Stripping Determination of Trace Nickel Using Bismuth Modified Mesoporous Carbon Composite Electrode

    Science.gov (United States)

    Ouyang, Ruizhuo; Feng, Kai; Su, Yongfu; Zong, Tianyu; Zhou, Xia; Lei, Tian; Jia, Pengpeng; Cao, Penghui; Zhao, Yuefeng; Guo, Ning; Chang, Haizhou; Miao, Yuqing; Zhou, Shuang

    Novel bismuth nanoparticle-modified mesoporous carbon (MPC) was successfully prepared on a glassy carbon electrode (Bi@MPC/GCE) for the adsorptive stripping voltammetric determination of nickel by complexing with dimethylglyoxime (DMG). The presence of MPC obviously improved the properties of Bi particles like the electron transfer ability, particle size and hydrophicility, important parameters to achieve preferable analytical performances of Bi@MPC/GCE toward Ni(II). The best electrochemical behaviors of Bi@MPC/GCE was obtained for the stripping determination of Ni(II), compared with electrodes individually modified with Bi and MPC. The synergic effect between metallic Bi and ordered MPC (forming a 3D array like Bi microelectrodes) made major contribution to such improved electrochemical properties of Bi@MPC/GCE for Ni(II) sensing. The good linear analytical curve was achieved in a Ni(II) concentration range from 0.1μM to 5.0μM with a correlation coefficient of 0.9995. The detection limit and sensitivity were calculated to be 1.2nM (S/N=3) and 1410μAmM-1cm-2, respectively. The new method was successfully applied to Ni(II) determination in soybean samples with recoveries higher than 99% and proved to be a simple, efficient alternative for Ni(II) monitoring in real samples.

  14. Optimizing the Stripping Procedure for LHCb

    CERN Document Server

    Richardson, Rachel

    2017-01-01

    The LHCb experiment faces a major challenge from the large amounts of data received while the LHC is running. The ability to sort this information in a useful manner is important for working groups to perform physics analyses. Both hardware and software triggers are used to decrease the data rate and then the stripping process is used to sort the data into streams and further into stripping lines. This project studies the hundreds of stripping lines to look for overlaps between them in order to make the stripping process more efficient.

  15. Rigorous results of low-energy models of the analytic S-matrix theory

    International Nuclear Information System (INIS)

    Meshcheryakov, V.A.

    1974-01-01

    Results of analytic S-matrix theory, mainly dealing with the static limit of dispersion relations, are applied to pion-nucleon scattering in the low-energy region. Various approaches to solving equations of the chew-Low type are discussed. It is concluded that interesting results are obtained by reducing the equations to a system of nonlinear difference equations; the crucial element of this approach being the study of functions on the whole Riemann surface. Boundary and crossing symmetry conditions are studied. (HFdV)

  16. Using Comic Strips in Language Classes

    Science.gov (United States)

    Csabay, Noémi

    2006-01-01

    The author believes that using comic strips in language-learning classes has three main benefits. First, comic strips motivate younger learners. Second, they provide a context and logically connected sentences to help language learning. Third, their visual information is helpful for comprehension. The author argues that comic strips can be used in…

  17. Evaluation of Directions for Use Compatibility Between Different Brands Strips Urine Reagent

    Directory of Open Access Journals (Sweden)

    Guilherme de Oliveira Cezar

    2012-06-01

    Full Text Available Through the urine test we can measure kidney function and identify pathologies of the urinary tract. The urine test strips are a fast, easy and increasingly used method of analysis. It is extremely important to check compatibility between the different brands assuring a better understanding of the diagnosis. We compared the package inserts of eight different brands of urine test strips and the reagents used in the urinary determination, besides information concerning the detection of limit ranges, reading intervals and possible interferences. A comparison of the leaflets showed differences among them. Concerning the reagents used, in general, all brands use similar ones but in different quantities. The patient information leaflets have several interferences, but it was observed that some brands do not mention the interferences that are mentioned in other brands. As for the legends of semiquantitative measurements, most brands do not include this information on the product leaflet. Among the brands that could be analyzed with this parameter was observed that the analytes glucose, bilirubin, ketones and blood did not have the same correlation between concentration and label brands. We stress the importance of ensuring a greater standardization of the information contained in the leaflets of the reagent strips.

  18. Test-beam evaluation of heavily irradiated silicon strip modules for ATLAS Phase-II Strip Tracker Upgrade

    CERN Document Server

    Blue, Andrew; The ATLAS collaboration

    2018-01-01

    The planned HL-LHC (High Luminosity LHC) is being designed to maximise the physics potential of the LHC with 10 years of operation at instantaneous luminosities of 7.5x1034cm−2s−1. A consequence of this increased luminosity is the expected radiation damage requiring the tracking detectors to withstand hadron equivalences to over 1x1015 1 MeV neutron equivalent per cm2 in the ATLAS Strips system. The silicon strip tracker exploits the concept of modularity. Fast readout electronics, deploying 130nm CMOS front-end electronics are glued on top of a silicon sensor to make a module. The radiation hard n-in-p micro-strip sensors used have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics. A series of tests were performed at the DESY-II and CERN SPS test beam facilities to investigate the detailed performance of a strip module with both 2.5cm and 5cm length strips before and after irradiation with 8x1014neqcm−2 protons and a total ionising dose of 37.2MRad. The DURA...

  19. Pavement Stripping in Saudi Arabia: Prediction and Prevention

    Directory of Open Access Journals (Sweden)

    H.I. Al-Abdul Wahhab

    2004-12-01

    Full Text Available Pavement weathering or stripping is a major distress in highway networks in arid regions. Using the Saudi Arabian road network as a case study area, seventeen road test sections were selected, out of which eight were stripped and nine were non-stripped. Aggregates from quarries used to build these sections were also collected and subjected to detailed physical and chemical tests to evaluate the ability of these tests to distinguish between stripped and non-stripped sections. The modified Lottman test was used to distinguish between compacted mixes. In addition, the Swedish Rolling Bottle test, was also found to be effective in being able to distinguish between different asphalt-aggregates for stripping potential. Eleven anti-stripping liquid additives, lime and cement, in addition to two polymers, were evaluated for their ability to reduce/eliminate stripping potential of stripping-prone aggregates. It was found that EE-2 Polymer, Portland cement, and their combination were effective with all aggregate sources.

  20. Disposable Electrochemical Immunosensor Diagnosis Device Based on Nanoparticle Probe and Immunochromatographic Strip

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guodong; Lin, Ying-Ying; Wang, Jun; Wu, Hong; Wai, Chien M.; Lin, Yuehe

    2007-10-15

    We describe a disposable electrochemical immunosensor diagnosis device that is based on the immunochromatographic strip technique and an electrochemical immunoassay based on quantum dot (QD, CdS@ZnS) labels. The device takes advantage of the speed and low-cost of the conventional immunochromatographic strip test and the high-sensitivity of the nanoparticle-based electrochemical immunoassay. A sandwich immunoreaction was performed on the immunochromatographic strip, and the captured QD labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable-screen-printed electrode, which is embedded underneath the membrane on the test zone. The new device coupled with a portable electrochemical analyzer shows great promise for in-field and point-of-care quantitative testing of disease-related protein biomarkers. The parameters (e.g., voltammetric measurement of QD labels, antibody immobilization, the loading amount of QD-antibody, and the immunoreaction time) that govern the sensitivity and reproducibility of the device were optimized with IgG model analyte. The voltammetric response of the optimized device is highly linear over the range of 0.1 to 10 ng mL-1 IgG, and the limit of detection is estimated to be 30 pg mL-1 in association with a 7-min immunoreaction time. The detection limit was improved to 10 pg mL-1 using a 20-min immunoreaction time. The new disposable electrochemical diagnosis device thus provides a more user-friendly, rapid, clinically accurate, less expensive, and quantitative tool for protein detection.

  1. Analytic MHD Theory for Earth's Bow Shock at Low Mach Numbers

    Science.gov (United States)

    Grabbe, Crockett L.; Cairns, Iver H.

    1995-01-01

    A previous MHD theory for the density jump at the Earth's bow shock, which assumed the Alfven M(A) and sonic M(s) Mach numbers are both much greater than 1, is reanalyzed and generalized. It is shown that the MHD jump equation can be analytically solved much more directly using perturbation theory, with the ordering determined by M(A) and M(s), and that the first-order perturbation solution is identical to the solution found in the earlier theory. The second-order perturbation solution is calculated, whereas the earlier approach cannot be used to obtain it. The second-order terms generally are important over most of the range of M(A) and M(s) in the solar wind when the angle theta between the normal to the bow shock and magnetic field is not close to 0 deg or 180 deg (the solutions are symmetric about 90 deg). This new perturbation solution is generally accurate under most solar wind conditions at 1 AU, with the exception of low Mach numbers when theta is close to 90 deg. In this exceptional case the new solution does not improve on the first-order solutions obtained earlier, and the predicted density ratio can vary by 10-20% from the exact numerical MHD solutions. For theta approx. = 90 deg another perturbation solution is derived that predicts the density ratio much more accurately. This second solution is typically accurate for quasi-perpendicular conditions. Taken together, these two analytical solutions are generally accurate for the Earth's bow shock, except in the rare circumstance that M(A) is less than or = 2. MHD and gasdynamic simulations have produced empirical models in which the shock's standoff distance a(s) is linearly related to the density jump ratio X at the subsolar point. Using an empirical relationship between a(s) and X obtained from MHD simulations, a(s) values predicted using the MHD solutions for X are compared with the predictions of phenomenological models commonly used for modeling observational data, and with the predictions of a

  2. Development of an analytical theory to describe the PNAR and CIPN nondestructive assay techniques

    International Nuclear Information System (INIS)

    Bolind, Alan Michael

    2014-01-01

    Highlights: • Neutron albedo is modeled by a discrete and iterative reflection process. • The theory enables the PNAR and CIPN NDA techniques to be compared quantitatively. • Improvements to the data analysis and to the CIPN instrument design are suggested. • A correction to translate real no-reflection PNAR data into ideal data is provided. - Abstract: This paper develops an analytical theory to describe how neutron albedo (reflection) increases the multiplication of neutrons by a used fuel assembly. With this theory, the two nondestructive assay (NDA) techniques of Passive Neutron Albedo Reactivity (PNAR) and Californium-252 Interrogation with Prompt Neutron Detection (CIPN) can be compared directly. Specifically, the theory derives expressions for the PNAR and CIPN metrics in terms of the physical properties of the used fuel assembly, such as the neutron multiplications and fate probabilities. The theory thus clarifies the interpretation of these two NDA techniques and suggests ways to improve both the design of the NDA instruments and the algorithms for analyzing the measurement results

  3. Analytic models of spectral responses of fiber-grating-based interferometers on FMC theory.

    Science.gov (United States)

    Zeng, Xiangkai; Wei, Lai; Pan, Yingjun; Liu, Shengping; Shi, Xiaohui

    2012-02-13

    In this paper the analytic models (AMs) of the spectral responses of fiber-grating-based interferometers are derived from the Fourier mode coupling (FMC) theory proposed recently. The interferometers include Fabry-Perot cavity, Mach-Zehnder and Michelson interferometers, which are constructed by uniform fiber Bragg gratings and long-period fiber gratings, and also by Gaussian-apodized ones. The calculated spectra based on the analytic models are achieved, and compared with the measured cases and those on the transfer matrix (TM) method. The calculations and comparisons have confirmed that the AM-based spectrum is in excellent agreement with the TM-based one and the measured case, of which the efficiency is improved up to ~2990 times that of the TM method for non-uniform-grating-based in-fiber interferometers.

  4. GASP. IX. Jellyfish galaxies in phase-space: an orbital study of intense ram-pressure stripping in clusters

    Science.gov (United States)

    Jaffé, Yara L.; Poggianti, Bianca M.; Moretti, Alessia; Gullieuszik, Marco; Smith, Rory; Vulcani, Benedetta; Fasano, Giovanni; Fritz, Jacopo; Tonnesen, Stephanie; Bettoni, Daniela; Hau, George; Biviano, Andrea; Bellhouse, Callum; McGee, Sean

    2018-06-01

    It is well known that galaxies falling into clusters can experience gas stripping due to ram pressure by the intra-cluster medium. The most spectacular examples are galaxies with extended tails of optically bright stripped material known as `jellyfish'. We use the first large homogeneous compilation of jellyfish galaxies in clusters from the WINGS and OmegaWINGS surveys, and follow-up MUSE observations from the GASP MUSE programme to investigate the orbital histories of jellyfish galaxies in clusters and reconstruct their stripping history through position versus velocity phase-space diagrams. We construct analytic models to define the regions in phase-space where ram-pressure stripping is at play. We then study the distribution of cluster galaxies in phase-space and find that jellyfish galaxies have on average higher peculiar velocities (and higher cluster velocity dispersion) than the overall population of cluster galaxies at all cluster-centric radii, which is indicative of recent infall into the cluster and radial orbits. In particular, the jellyfish galaxies with the longest gas tails reside very near the cluster cores (in projection) and are moving at very high speeds, which coincides with the conditions of the most intense ram pressure. We conclude that many of the jellyfish galaxies seen in clusters likely formed via fast (˜1-2 Gyr), incremental, outside-in ram-pressure stripping during first infall into the cluster in highly radial orbits.

  5. Sensitive and stable monitoring of lead and cadmium in seawater using screen-printed electrode and electrochemical stripping analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gueell, Raquel [ICREA and Nanobioelectronics and Biosensors Group, Institut Catala de Nanotecnologia, Bellaterra, Barcelona (Spain); Department of Chemistry, Universitat Autonoma de Barcelona, Bellaterra, Barcelona (Spain); Department of Chemistry, University of Girona, Campus Montilivi, 17071 Girona (Spain); Aragay, Gemma [ICREA and Nanobioelectronics and Biosensors Group, Institut Catala de Nanotecnologia, Bellaterra, Barcelona (Spain); Department of Chemistry, Universitat Autonoma de Barcelona, Bellaterra, Barcelona (Spain); Fontas, Claudia; Antico, Enriqueta [Department of Chemistry, University of Girona, Campus Montilivi, 17071 Girona (Spain); Merkoci, Arben [ICREA and Nanobioelectronics and Biosensors Group, Institut Catala de Nanotecnologia, Bellaterra, Barcelona (Spain); Department of Chemistry, Universitat Autonoma de Barcelona, Bellaterra, Barcelona (Spain)], E-mail: arben.merkoci.icn@uab.es

    2008-10-10

    Sensitive and stable monitoring of heavy metals in seawater using screen-printed electrodes (SPE) is presented. The analytical performance of SPE coupled with square wave anodic stripping voltammetry (SWASV) for the simultaneous determination of Pb and Cd in seawater samples, in the low {mu}g L{sup -1} range, is evaluated. The stripping response for the heavy metals following 2 min deposition was linear over the concentration range examined (10-2000 {mu}g L{sup -1}) with detection limits of 1.8 and 2.9 {mu}g L{sup -1} for Pb and Cd, respectively. The accuracy of the method was validated by analyzing metal contents in different spiked seawater samples and comparing these results to those obtained with the well-established anodic stripping voltammetry using the hanging mercury drop electrode. Moreover, a certified reference material was also used and the results obtained were satisfactory.

  6. Optimal Cluster Mill Pass Scheduling With an Accurate and Rapid New Strip Crown Model

    International Nuclear Information System (INIS)

    Malik, Arif S.; Grandhi, Ramana V.; Zipf, Mark E.

    2007-01-01

    and predict the strip crown, a new customized semi-analytical modeling technique that couples the Finite Element Method (FEM) with classical solid mechanics was developed to model the deflection of the rolls and strip while under load. The technique employed offers several important advantages over traditional methods to calculate strip crown, including continuity of elastic foundations, non-iterative solution when using predetermined foundation moduli, continuous third-order displacement fields, simple stress-field determination, and a comparatively faster solution time

  7. Gauge field geometry from complex and harmonic analyticities

    International Nuclear Information System (INIS)

    Gal'perin, A.S.; Ivanov, E.A.; Ogievetsky, V.I.; Sokatchev, E.

    1987-01-01

    The analyticity preservation principle is employed to demonstrate and impressive affinity between field theories with intrinsic analytic structure and superfield gauge theories. The defining constraints of the former theories are interpreted as the integrability conditions for the existence of appropriate analytic subspaces and are solved by passing to the basis with manifest analyticity. We prefer to work within the analytic basis. This allows, e.g., to replace the nonlinear splitting problem of twistor approach by solving a linear equation

  8. Large strip RPCs for the LEPS2 TOF system

    Energy Technology Data Exchange (ETDEWEB)

    Tomida, N., E-mail: natsuki@scphys.kyoto-u.ac.jp [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Niiyama, M. [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Ohnishi, H. [RIKEN (The Institute of Physical and Chemical Research), Wako, Saitama 351-0198 (Japan); Tran, N. [Research Center for Nuclear Physics (RCNP), Osaka University, Ibaraki, Osaka 567-0047 (Japan); Hsieh, C.-Y.; Chu, M.-L.; Chang, W.-C. [Institute of Physics, Academia Sinica, Nankang, Taipei 11529, Taiwan (China); Chen, J.-Y. [National Synchrotron Radiation Research Center (NSRRC), Hsinchu 30076, Taiwan (China)

    2014-12-01

    High time-resolution resistive plate chambers (RPCs) with large-size readout strips are developed for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. The experimental requirement is a 50-ps time resolution for a strip size larger than 100 cm{sup 2}/channel. We are able to achieve 50-ps time resolutions with 2.5×100 cm{sup 2} strips by directly connecting the amplifiers to strips. With the same time resolution, the number of front-end electronics (FEE) is also reduced by signal addition. - Highlights: • Find a way to achieve a good time resolution with a large strip RPC. • 2.5 cm narrow strips have better resolutions than 5.0 cm ones. • The 0.5 mm narrow strip interval shows flat time resolutions between strips. • FEEs directly connected to strips make the signal reflection at the strip edge small. • A time resolution of 50 ps was achieved with 2.5 cm×100 cm strips.

  9. Semi-analytical quasi-normal mode theory for the local density of states in coupled photonic crystal cavity-waveguide structures

    DEFF Research Database (Denmark)

    de Lasson, Jakob Rosenkrantz; Kristensen, Philip Trøst; Mørk, Jesper

    2015-01-01

    We present and validate a semi-analytical quasi-normal mode (QNM) theory for the local density of states (LDOS) in coupled photonic crystal (PhC) cavity-waveguide structures. By means of an expansion of the Green's function on one or a few QNMs, a closed-form expression for the LDOS is obtained, ......-trivial spectrum with a peak and a dip is found, which is reproduced only when including both the two relevant QNMs in the theory. In both cases, we find relative errors below 1% in the bandwidth of interest.......We present and validate a semi-analytical quasi-normal mode (QNM) theory for the local density of states (LDOS) in coupled photonic crystal (PhC) cavity-waveguide structures. By means of an expansion of the Green's function on one or a few QNMs, a closed-form expression for the LDOS is obtained......, and for two types of two-dimensional PhCs, with one and two cavities side-coupled to an extended waveguide, the theory is validated against numerically exact computations. For the single cavity, a slightly asymmetric spectrum is found, which the QNM theory reproduces, and for two cavities a non...

  10. Mechanical behaviour of a creased thin strip

    Directory of Open Access Journals (Sweden)

    J. Liu

    2018-02-01

    Full Text Available In this study the mechanical behaviour of a creased thin strip under opposite-sense bending was investigated. It was found that a simple crease, which led to the increase of the second moment of area, could significantly alter the overall mechanical behaviour of a thin strip, for example the peak moment could be increased by 100 times. The crease was treated as a cylindrical segment of a small radius. Parametric studies demonstrated that the geometry of the strip could strongly influence its flexural behaviour. We showed that the uniform thickness and the radius of the creased segment had the greatest and the least influence on the mechanical behaviour, respectively. We further revealed that material properties could dramatically affect the overall mechanical behaviour of the creased strip by gradually changing the material from being linear elastic to elastic-perfect plastic. After the formation of the fold, the moment of the two ends of the strip differed considerably when the elasto-plastic materials were used, especially for materials with smaller tangent modulus in the plastic range. The deformation patterns of the thin strips from the finite element simulations were verified by physical models made of thin metal strips. The findings from this study provide useful information for designing origami structures for engineering applications using creased thin strips.

  11. Comparative limnology of strip-mine lakes

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, J D

    1964-01-01

    Lakes were classified according to chemical properties. The concentration of the ferric iron oxides was responsible for a reddish-black turbidity which, in turn, played a major role in the thermal stratification of red strip-mine lakes. Owing to the lack of measurable turbidity and as a result of selective absorption of visible solar radiation, other strip-mine lakes appeared blue in color. The annual heat budget and the summer heat budget are essentially equivalent under saline conditions. Regardless of the physical and chemical conditions of the strip-mine lakes, heat income was a function of the circulating water mass. The progressive oxidation and precipitation of the iron oxides is the key to the classification of strip-mine lakes.

  12. Development of a one-step immunochromatographic strip test for the detection of sennosides A and B.

    Science.gov (United States)

    Putalun, Waraporn; Morinaga, Osamu; Tanaka, Hiroyuki; Shoyama, Yukihiro

    2004-01-01

    An immunochromatographic strip test was developed to detect sennoside A (1) and sennoside B (2) using anti-1 and anti-2 monoclonal antibodies. The qualitative assay was based on a competitive immunoassay in which the detector reagent consisted of colloidal gold particles coated with the respective sennoside antibodies. The capture reagents were 1- and 2-human serum albumin (HSA) conjugates immobilised on a nitrocellulose membrane on the test strip. The sample containing 1 and 2, together with detector reagent, passed over the zone where the capture reagents had been immobilised. The analytes in the sample competed for binding to the limited amount of antibodies in the detector reagent with the immobilised 1- and 2-HSA conjugates on the membrane and hence positive samples showed no colour in the capture spot zone. Detection limits for the strip test were 125 ng/mL for both sennosides. The assay system is useful as a rapid and simple screening method for the detection of 1 and 2 in plants, drugs and body fluids.

  13. Using meta-analytic path analysis to test theoretical predictions in health behavior: An illustration based on meta-analyses of the theory of planned behavior.

    Science.gov (United States)

    Hagger, Martin S; Chan, Derwin K C; Protogerou, Cleo; Chatzisarantis, Nikos L D

    2016-08-01

    Synthesizing research on social cognitive theories applied to health behavior is an important step in the development of an evidence base of psychological factors as targets for effective behavioral interventions. However, few meta-analyses of research on social cognitive theories in health contexts have conducted simultaneous tests of theoretically-stipulated pattern effects using path analysis. We argue that conducting path analyses of meta-analytic effects among constructs from social cognitive theories is important to test nomological validity, account for mediation effects, and evaluate unique effects of theory constructs independent of past behavior. We illustrate our points by conducting new analyses of two meta-analyses of a popular theory applied to health behaviors, the theory of planned behavior. We conducted meta-analytic path analyses of the theory in two behavioral contexts (alcohol and dietary behaviors) using data from the primary studies included in the original meta-analyses augmented to include intercorrelations among constructs and relations with past behavior missing from the original analysis. Findings supported the nomological validity of the theory and its hypotheses for both behaviors, confirmed important model processes through mediation analysis, demonstrated the attenuating effect of past behavior on theory relations, and provided estimates of the unique effects of theory constructs independent of past behavior. Our analysis illustrates the importance of conducting a simultaneous test of theory-stipulated effects in meta-analyses of social cognitive theories applied to health behavior. We recommend researchers adopt this analytic procedure when synthesizing evidence across primary tests of social cognitive theories in health. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Thermally assisted peeling of an elastic strip in adhesion with a substrate via molecular bonds

    Science.gov (United States)

    Qian, Jin; Lin, Ji; Xu, Guang-Kui; Lin, Yuan; Gao, Huajian

    A statistical model is proposed to describe the peeling of an elastic strip in adhesion with a flat substrate via an array of non-covalent molecular bonds. Under an imposed tensile peeling force, the interfacial bonds undergo diffusion-type transition in their bonding state, a process governed by a set of probabilistic equations coupled to the stretching, bending and shearing of the elastic strip. Because of the low characteristic energy scale associated with molecular bonding, thermal excitations are found to play an important role in assisting the escape of individual molecular bonds from their bonding energy well, leading to propagation of the peeling front well below the threshold peel-off force predicted by the classical theories. Our study establishes a link between the deformation of the strip and the spatiotemporal evolution of interfacial bonds, and delineates how factors like the peeling force, bending rigidity of the strip and binding energy of bonds influence the resultant peeling velocity and dimensions of the process zone. In terms of the apparent adhesion strength and dissipated energy, the bond-mediated interface is found to resist peeling in a strongly rate-dependent manner.

  15. Weak-field asymptotic theory of tunneling ionization: benchmark analytical results for two-electron atoms

    International Nuclear Information System (INIS)

    Trinh, Vinh H; Morishita, Toru; Tolstikhin, Oleg I

    2015-01-01

    The recently developed many-electron weak-field asymptotic theory of tunneling ionization of atoms and molecules in an external static electric field (Tolstikhin et al 2014, Phys. Rev. A 89, 013421) is extended to the first-order terms in the asymptotic expansion in field. To highlight the results, here we present a simple analytical formula giving the rate of tunneling ionization of two-electron atoms H − and He. Comparison with fully-correlated ab initio calculations available for these systems shows that the first-order theory works quantitatively in a wide range of fields up to the onset of over-the-barrier ionization and hence is expected to find numerous applications in strong-field physics. (fast track communication)

  16. Comparison of adsorptive with extractive stripping voltammetry in electrochemical determination of retinol

    Directory of Open Access Journals (Sweden)

    Milan Sýs

    2017-01-01

    Full Text Available Adsorptive stripping voltammetry (AdSV of retinol at solid glassy carbon electrode (GCE, carbon paste electrode (CPE covered by thin layer of multi-wall carbon nanotubes (CPE/MWCNTs and carbon paste electrode covered by thin layer of single layer graphene (CPE/Graphene was compared with an extractive stripping voltammetry (ExSV into silicone oil (SO as lipophilic binder of glassy carbon paste electrode (GCPE. All types of selected working electrodes were characterized by a scanning electron microscopy to determine overall morphology of electrode surfaces together with spatial arrangement of used carbon particles. The retinol, also known as vitamin A1, was chosen as a model analyte because it is the most biologically active representative of retinoids which are classified as a significant group of lipophilic vitamins. Based on this comparison, it was observed that electrochemical method with high sensitivity (ExSV at GPCE is generally characterized by shorter linear range of the calibration curve than in case of AdSV at CPE/MWCNTs or CPE/Graphene. Unlike AdSV at solid GCE, all other tested electrochemical methods could represent suitable analytical tools for monitoring of retinoids in different types of foodstuffs. Especially, content of retinol up to tenths milligrams can be easily determined using ExSV. Additionally, negative interference of chemical species present in real samples is minimal in comparison with direct voltammetric methods performed in supporting electrolytes based on organic solvents due to application of accumulation step in "ex-situ" mode.

  17. Limit theorems for random walks on a strip in subdiffusive regimes

    International Nuclear Information System (INIS)

    Dolgopyat, D; Goldsheid, I

    2013-01-01

    We study the asymptotic behaviour of occupation times of a transient random walk (RW) in a quenched random environment (RE) on a strip in a subdiffusive regime. The asymptotic behaviour of hitting times, which is a more traditional object of study, is exactly the same. As a particular case, we solve a long standing problem of describing the asymptotic behaviour of a RW with bounded jumps on a one-dimensional lattice. Our technique results from the development of ideas from our previous work (Dolgopyat and Goldsheid 2012 Commun. Math. Phys. 315 241–77) on the simple RWs in RE and those used in Bolthausen and Goldsheid (2000 Commun. Math. Phys. 214 429–47; 2008 Commun. Math. Phys. 278 253–88) and Goldsheid (2008 Probab. Theory Relat. Fields 141 471–511) for the study of random walks on a strip. (paper)

  18. Directivity patterns and pulse profiles of ultrasound emitted by laser action on interface between transparent and opaque solids: Analytical theory

    International Nuclear Information System (INIS)

    Nikitin, Sergey M.; Tournat, Vincent; Chigarev, Nikolay; Castagnede, Bernard; Gusev, Vitalyi; Bulou, Alain; Zerr, Andreas

    2014-01-01

    The analytical theory for the directivity patterns of ultrasounds emitted from laser-irradiated interface between two isotropic solids is developed. It is valid for arbitrary combinations of transparent and opaque materials. The directivity patterns are derived both in two-dimensional and in three-dimensional geometries, by accounting for the specific features of the sound generation by the photo-induced mechanical stresses distributed in the volume, essential in the laser ultrasonics. In particular, the theory accounts for the contribution to the emitted propagating acoustic fields from the converted by the interface evanescent photo-generated compression-dilatation waves. The precise analytical solutions for the profiles of longitudinal and shear acoustic pulses emitted in different directions are proposed. The developed theory can be applied for dimensional scaling, optimization, and interpretation of the high-pressure laser ultrasonics experiments in diamond anvil cell

  19. Entanglement growth after a global quench in free scalar field theory

    Energy Technology Data Exchange (ETDEWEB)

    Cotler, Jordan S. [Stanford Institute for Theoretical Physics, Department of Physics, Stanford University, Stanford, CA 94305 (United States); Hertzberg, Mark P. [Institute of Cosmology, Department of Physics and Astronomy, Tufts University, Medford, MA 02155 (United States); Mezei, Márk [Princeton Center for Theoretical Science, Princeton University, Princeton, NJ 08544 (United States); Mueller, Mark T. [Center for Theoretical Physics, Department of Physics, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)

    2016-11-28

    We compute the entanglement and Rényi entropy growth after a global quench in various dimensions in free scalar field theory. We study two types of quenches: a boundary state quench and a global mass quench. Both of these quenches are investigated for a strip geometry in 1, 2, and 3 spatial dimensions, and for a spherical geometry in 2 and 3 spatial dimensions. We compare the numerical results for massless free scalars in these geometries with the predictions of the analytical quasiparticle model based on EPR pairs, and find excellent agreement in the limit of large region sizes. At subleading order in the region size, we observe an anomalous logarithmic growth of entanglement coming from the zero mode of the scalar.

  20. Answer first: Applying the heuristic-analytic theory of reasoning to examine student intuitive thinking in the context of physics

    Directory of Open Access Journals (Sweden)

    Mila Kryjevskaia

    2014-07-01

    Full Text Available We have applied the heuristic-analytic theory of reasoning to interpret inconsistencies in student reasoning approaches to physics problems. This study was motivated by an emerging body of evidence that suggests that student conceptual and reasoning competence demonstrated on one task often fails to be exhibited on another. Indeed, even after instruction specifically designed to address student conceptual and reasoning difficulties identified by rigorous research, many undergraduate physics students fail to build reasoning chains from fundamental principles even though they possess the required knowledge and skills to do so. Instead, they often rely on a variety of intuitive reasoning strategies. In this study, we developed and employed a methodology that allowed for the disentanglement of student conceptual understanding and reasoning approaches through the use of sequences of related questions. We have shown that the heuristic-analytic theory of reasoning can be used to account for, in a mechanistic fashion, the observed inconsistencies in student responses. In particular, we found that students tended to apply their correct ideas in a selective manner that supported a specific and likely anticipated conclusion while neglecting to employ the same ideas to refute an erroneous intuitive conclusion. The observed reasoning patterns were consistent with the heuristic-analytic theory, according to which reasoners develop a “first-impression” mental model and then construct an argument in support of the answer suggested by this model. We discuss implications for instruction and argue that efforts to improve student metacognition, which serves to regulate the interaction between intuitive and analytical reasoning, is likely to lead to improved student reasoning.

  1. Superconducting nano-strip particle detectors

    International Nuclear Information System (INIS)

    Cristiano, R; Ejrnaes, M; Casaburi, A; Zen, N; Ohkubo, M

    2015-01-01

    We review progress in the development and applications of superconducting nano-strip particle detectors. Particle detectors based on superconducting nano-strips stem from the parent devices developed for single photon detection (SSPD) and share with them ultra-fast response times (sub-nanosecond) and the ability to operate at a relatively high temperature (2–5 K) compared with other cryogenic detectors. SSPDs have been used in the detection of electrons, neutral and charged ions, and biological macromolecules; nevertheless, the development of superconducting nano-strip particle detectors has mainly been driven by their use in time-of-flight mass spectrometers (TOF-MSs) where the goal of 100% efficiency at large mass values can be achieved. Special emphasis will be given to this case, reporting on the great progress which has been achieved and which permits us to overcome the limitations of existing mass spectrometers represented by low detection efficiency at large masses and charge/mass ambiguity. Furthermore, such progress could represent a breakthrough in the field. In this review article we will introduce the device concept and detection principle, stressing the peculiarities of the nano-strip particle detector as well as its similarities with photon detectors. The development of parallel strip configuration is introduced and extensively discussed, since it has contributed to the significant progress of TOF-MS applications. (paper)

  2. Disposable screen-printed bismuth electrode modified with multi-walled carbon nanotubes for electrochemical stripping measurements.

    Science.gov (United States)

    Niu, Xiangheng; Zhao, Hongli; Lan, Minbo

    2011-01-01

    Integrating the advantages of screen printing technology with the encouraging electroanalytical characteristic of metallic bismuth, we developed an ultrasensitive and disposable screen-printed bismuth electrode (SPBE) modified with multi-walled carbon nanotubes (MWCNTs) for electrochemical stripping measurements. Metallic bismuth powders and MWCNTs were homogeneously mixed with graphite-carbon ink to mass-prepare screen-printed bismuth electrode doped with multi-walled carbon nanotubes (SPBE/MWCNT). The electroanalytical performance of the prepared SPBE/MWCNT was intensively evaluated by measuring trace Hg(II) with square-wave anodic stripping voltammetry (SWASV). The results indicated that the SPBE modified with 2 wt% MWCNTs could offer a more sensitive response to trace Hg(II) than the bare SPBE. The stripping current obtained at SPBE/MWCNT was linear with Hg(II) concentration in the range from 0.2 to 40 µg/L (R(2) = 0.9976), with a detection limit of 0.09 µg/L (S/N = 3) under 180 s accumulation. The proposed "mercury-free" electrode, with extremely simple preparation and ultrahigh sensitivity, holds wide application prospects in both environmental and industrial monitoring. 2011 © The Japan Society for Analytical Chemistry

  3. Depletive stripping chronopotentiometry : a major step forward in electrochemical stripping techniques for metal ion speciation analysis

    NARCIS (Netherlands)

    Town, R.M.; Leeuwen, van H.P.

    2004-01-01

    A comparative evaluation of the utility of the various modes of stripping chronopotentiometry (SCP) for trace metal speciation analysis is presented in the broad context of stripping voltammetric techniques. The remarkable fundamental advantages of depletive SCP at scanned deposition potential

  4. Analytical theory and possible detection of the ac quantum spin Hall effect.

    Science.gov (United States)

    Deng, W Y; Ren, Y J; Lin, Z X; Shen, R; Sheng, L; Sheng, D N; Xing, D Y

    2017-07-11

    We develop an analytical theory of the low-frequency ac quantum spin Hall (QSH) effect based upon the scattering matrix formalism. It is shown that the ac QSH effect can be interpreted as a bulk quantum pumping effect. When the electron spin is conserved, the integer-quantized ac spin Hall conductivity can be linked to the winding numbers of the reflection matrices in the electrodes, which also equal to the bulk spin Chern numbers of the QSH material. Furthermore, a possible experimental scheme by using ferromagnetic metals as electrodes is proposed to detect the topological ac spin current by electrical means.

  5. Breakup-fusion analyses of light ion induced stripping reactions to both bound and unbound regions

    International Nuclear Information System (INIS)

    Lee, Y.J.

    1987-01-01

    The breakup-fusion theory developed recently by our group at the University of Texas has been very successful in explaining observed continuum spectra of particles emitted from breakup type reactions, such as (d,p), (h,p), (h,d), (α,p), and (α,t) reactions. The aim of the present work is to extend the breakup-fusion formalism to calculate the usual stripping reaction, in which a nucleon or a nucleon-cluster is transferred into abound orbit in the target nucleus. With this extension, it is now possible to calculate the spectra of particles emitted from stripping type reactions. We particularly explore the possibility of using the breakup-fusion theory as a spectroscopic tool to obtain information about single particle states in both bound and unbound regions. For this purpose, we extend the theory so as to include the spin-orbit interaction between the transferred particle and the target which has been neglected in all the breakup-fusion studies made in the past. We then apply the thus extended breakup-fusion theory to analyze data of (d,p) and (α,t) reactions. The results of the calculations fit the observed spectra very well and the BF method is shown indeed to be useful for extracting information about the single particle states observed as bumps in both the continuum and discrete regions

  6. From observational to analytical morphology of the stratum corneum: progress avoiding hazardous animal and human testings

    Directory of Open Access Journals (Sweden)

    Piérard GE

    2015-03-01

    Full Text Available Gérald E Piérard,1,2 Justine Courtois,1 Caroline Ritacco,1 Philippe Humbert,2,3 Ferial Fanian,3 Claudine Piérard-Franchimont1,4,5 1Laboratory of Skin Bioengineering and Imaging (LABIC, Department of Clinical Sciences, Liège University, Liège, Belgium; 2University of Franche-Comté, Besançon, France; 3Department of Dermatology, University Hospital Saint-Jacques, Besançon, France; 4Department of Dermatopathology, Unilab Lg, University Hospital of Liège, Liège, Belgium; 5Department of Dermatology, Regional Hospital of Huy, Huy, Belgium Background: In cosmetic science, noninvasive sampling of the upper part of the stratum corneum is conveniently performed using strippings with adhesive-coated discs (SACD and cyanoacrylate skin surface strippings (CSSSs. Methods: Under controlled conditions, it is possible to scrutinize SACD and CSSS with objectivity using appropriate methods of analytical morphology. These procedures apply to a series of clinical conditions including xerosis grading, comedometry, corneodynamics, corneomelametry, corneosurfametry, corneoxenometry, and dandruff assessment. Results: With any of the analytical evaluations, SACD and CSSS provide specific salient information that is useful in the field of cosmetology. In particular, both methods appear valuable and complementary in assessing the human skin compatibility of personal skincare products. Conclusion: A set of quantitative analytical methods applicable to the minimally invasive and low-cost SACD and CSSS procedures allow for a sound assessment of cosmetic effects on the stratum corneum. Under regular conditions, both methods are painless and do not induce adverse events. Globally, CSSS appears more precise and informative than the regular SACD stripping. Keywords: irritation, morphometry, quantitative morphology, stripping

  7. Analytic perturbation theory for screened Coulomb potential: full continuum wave function

    International Nuclear Information System (INIS)

    Bechler, A.; Ennan, Mc J.; Pratt, R.H.

    1979-01-01

    An analytic perturbation theory developed previously is used to find a continuum screened-Coulomb wave function characterized by definite asymptotic momentum. This wave function satisfies an inhomogeneous partial differential equation which is solved in parabolic coordinates; the solution depends on both parabolic variables. We calculate partial wave projections of this solution and show that we can choose to add a solution of the homogeneous equation such that the partial wave projections become equal to the normalized continuum radial function found previously. However, finding the unique solution with given asymptotic linear momentum will require either using boundary conditions to determine the unique needed solution of the homogeneous equation or equivalently specifying the screened-Coulomb phase-shifts. (author)

  8. Ductility of reinforced concrete columns confined with stapled strips

    International Nuclear Information System (INIS)

    Tahir, M.F.; Khan, Q.U.Z.; Shabbir, F.; Sharif, M.B.; Ijaz, N.

    2015-01-01

    Response of three 150x150x450mm short reinforced concrete (RC) columns confined with different types of confining steel was investigated. Standard stirrups, strips and stapled strips, each having same cross-sectional area, were employed as confining steel around four comer column bars. Experimental work was aimed at probing into the affect of stapled strip confinement on post elastic behavior and ductility level under cyclic axial load. Ductility ratios, strength enhancement factor and core concrete strengths were compared to study the affect of confinement. Results indicate that strength enhancement in RC columns due to strip and stapled strip confinement was not remarkable as compared to stirrup confined column. It was found that as compared to stirrup confined column, stapled strip confinement enhanced the ductility of RC column by 183% and observed axial capacity of stapled strip confined columns was 41 % higher than the strip confined columns. (author)

  9. Potential profile in a conducting polymer strip

    DEFF Research Database (Denmark)

    Bay, Lasse; West, Keld; Vlachopoulos, Nikolaos

    2002-01-01

    Many conjugated polymers show an appreciable difference in volume between their oxidized and reduced forms. This property can be utilized in soft electrochemically driven actuators, "artificial muscles". Several geometries have been proposed for the conversion of the volume expansion into useful...... mechanical work. In a particularly simple geometry, the length change of polymer strips is exploited. The polymer strips are connected to the driving circuit at the end of the strip that is attached to the support of the device. The other end of the strip is connected to the load. The advantage of this set...

  10. Study on lifetime of C stripping foils

    International Nuclear Information System (INIS)

    Zhang Hongbin; Lu Ziwei; Zhao Yongtao; Li Zhankui; Xu Hushan; Xiao Guoqing; Wang Yuyu; Zhang Ling; Li Longcai; Fang Yan

    2007-01-01

    The carbon stripping foils can be prepared with the AC and DC arc discharge methods, or even sandwiched with AC-DC alternative layers. The lifetime of the carbon stripping foils of 19 μg/cm 2 prepared with different methods and/or structures was measured. The factors affecting the bombarding lifetime of the carbon stripping foils, especially the method of the foil preparation and the structure of the carbon stripping foils, were discussed. It is observed that the foils prepared with the DC arc discharge method have a longer bombarding lifetime than those prepared with the AC arc discharge method. (authors)

  11. Coherent states with classical motion: from an analytic method complementary to group theory

    International Nuclear Information System (INIS)

    Nieto, M.M.

    1982-01-01

    From the motivation of Schroedinger, that of finding states which follow the motion which a classical particle would have in a given potential, we discuss generalizations of the coherent states of the harmonic oscillator. We focus on a method which is the analytic complement to the group theory point of view. It uses a minimum uncertainty formalism as its basis. We discuss the properties and time evolution of these states, always keeping in mind the desire to find quantum states which follow the classical motion

  12. Combined micro-droplet and thin-film-assisted pre-concentration of lead traces for on-line monitoring using anodic stripping voltammetry.

    Science.gov (United States)

    Belostotsky, Inessa; Gridin, Vladimir V; Schechter, Israel; Yarnitzky, Chaim N

    2003-02-01

    An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead.

  13. Combined micro-droplet and thin-film-assisted pre-concentration of lead traces for on-line monitoring using anodic stripping voltammetry

    Energy Technology Data Exchange (ETDEWEB)

    Belostotsky, Inessa; Gridin, Vladimir V.; Schechter, Israel; Yarnitzky, Chaim N. [Department of Chemistry, Technion Israel Institute of Technology, 32000, Haifa (Israel)

    2003-02-01

    An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead. (orig.)

  14. Analytic trigonometry

    CERN Document Server

    Bruce, William J; Maxwell, E A; Sneddon, I N

    1963-01-01

    Analytic Trigonometry details the fundamental concepts and underlying principle of analytic geometry. The title aims to address the shortcomings in the instruction of trigonometry by considering basic theories of learning and pedagogy. The text first covers the essential elements from elementary algebra, plane geometry, and analytic geometry. Next, the selection tackles the trigonometric functions of angles in general, basic identities, and solutions of equations. The text also deals with the trigonometric functions of real numbers. The fifth chapter details the inverse trigonometric functions

  15. The analytic foundations of Regge theory

    International Nuclear Information System (INIS)

    White, A.R.

    1976-01-01

    Regge poles were first introduced into relativistic scattering theory nearly fifteen years ago. The necessity for accompanying Regge cuts was discovered within two years. The intervening years have seen a gradual improvement of our understanding of Regge theory, but, particularly at the multiparticle level, the theory has remained incomplete with its fundamental status unclear. However, on the basis of recent progress a complete and systematic development of the Regge theory of elastic and multiparticle amplitude is given. (Auth.)

  16. Sound propagation in dilute suspensions of spheres: Analytical comparison between coupled phase model and multiple scattering theory.

    Science.gov (United States)

    Valier-Brasier, Tony; Conoir, Jean-Marc; Coulouvrat, François; Thomas, Jean-Louis

    2015-10-01

    Sound propagation in dilute suspensions of small spheres is studied using two models: a hydrodynamic model based on the coupled phase equations and an acoustic model based on the ECAH (ECAH: Epstein-Carhart-Allegra-Hawley) multiple scattering theory. The aim is to compare both models through the study of three fundamental kinds of particles: rigid particles, elastic spheres, and viscous droplets. The hydrodynamic model is based on a Rayleigh-Plesset-like equation generalized to elastic spheres and viscous droplets. The hydrodynamic forces for elastic spheres are introduced by analogy with those of droplets. The ECAH theory is also modified in order to take into account the velocity of rigid particles. Analytical calculations performed for long wavelength, low dilution, and weak absorption in the ambient fluid show that both models are strictly equivalent for the three kinds of particles studied. The analytical calculations show that dilatational and translational mechanisms are modeled in the same way by both models. The effective parameters of dilute suspensions are also calculated.

  17. Locally analytic vectors in representations of locally

    CERN Document Server

    Emerton, Matthew J

    2017-01-01

    The goal of this memoir is to provide the foundations for the locally analytic representation theory that is required in three of the author's other papers on this topic. In the course of writing those papers the author found it useful to adopt a particular point of view on locally analytic representation theory: namely, regarding a locally analytic representation as being the inductive limit of its subspaces of analytic vectors (of various "radii of analyticity"). The author uses the analysis of these subspaces as one of the basic tools in his study of such representations. Thus in this memoir he presents a development of locally analytic representation theory built around this point of view. The author has made a deliberate effort to keep the exposition reasonably self-contained and hopes that this will be of some benefit to the reader.

  18. Ultrasonic examination of JBK-75 strip material

    International Nuclear Information System (INIS)

    Cook, K.V.; Cunningham, R.A. Jr.; Lewis, J.C.; McClung, R.W.

    1982-12-01

    An ultrasonic inspection system was assembled to inspect the JBK-75 stainless steel sheath material (for the Large Coil Project) for the Westinghouse-Airco superconducting magnet program. The mechanical system provided for handling the 180-kg (400-lb) coils of strip material [1.6 mm thick by 78 mm wide by 90 to 120 m long (0.064 by 3.07 in. by 300 to 400 ft)], feeding the strip through the ultrasonic inspection and cleaning stations, and respooling the coils. We inspected 54 coils of strip for both longitudinal and laminar flaws. Simulated flaws were used to calibrate both inspections. Saw-cut notches [0.28 mm deep (0.011 in., about 17% of the strip thickness)] were used to calibrate the longitudinal flaw inspections; 1.59-mm-diam (0.063-in.) flat-bottom holes drilled halfway through a calibration strip were used to calibrate the laminar flaw tests

  19. Hardness of approximation for strip packing

    DEFF Research Database (Denmark)

    Adamaszek, Anna Maria; Kociumaka, Tomasz; Pilipczuk, Marcin

    2017-01-01

    Strip packing is a classical packing problem, where the goal is to pack a set of rectangular objects into a strip of a given width, while minimizing the total height of the packing. The problem has multiple applications, for example, in scheduling and stock-cutting, and has been studied extensively......)-approximation by two independent research groups [FSTTCS 2016,WALCOM 2017]. This raises a questionwhether strip packing with polynomially bounded input data admits a quasi-polynomial time approximation scheme, as is the case for related twodimensional packing problems like maximum independent set of rectangles or two...

  20. Analytic result for the two-loop six-point NMHV amplitude in N=4 super Yang-Mills theory

    CERN Document Server

    Dixon, Lance J.; Henn, Johannes M.

    2012-01-01

    We provide a simple analytic formula for the two-loop six-point ratio function of planar N = 4 super Yang-Mills theory. This result extends the analytic knowledge of multi-loop six-point amplitudes beyond those with maximal helicity violation. We make a natural ansatz for the symbols of the relevant functions appearing in the two-loop amplitude, and impose various consistency conditions, including symmetry, the absence of spurious poles, the correct collinear behaviour, and agreement with the operator product expansion for light-like (super) Wilson loops. This information reduces the ansatz to a small number of relatively simple functions. In order to fix these parameters uniquely, we utilize an explicit representation of the amplitude in terms of loop integrals that can be evaluated analytically in various kinematic limits. The final compact analytic result is expressed in terms of classical polylogarithms, whose arguments are rational functions of the dual conformal cross-ratios, plus precisely two function...

  1. Effect of strip temperature on the formation of an Fe{sub 2}Al{sub 5} inhibition layer during hot-dip galvanizing

    Energy Technology Data Exchange (ETDEWEB)

    Dutta, Monojit [R and D Division, Tata Steel Ltd., Jamshedpur 831001 (India)], E-mail: monoron@yahoo.com; Singh, Shiv Brat [Department of Metallurgical and Materials Engineering, Indian Institute of Technology, Kharagpur 721302 (India)

    2009-04-15

    The theory of nucleation has been employed to derive expressions for the formation of an Fe{sub 2}Al{sub 5} layer during commercial strip galvanizing. This is then used to show the effect of the strip entry temperature on the nucleation of the Fe{sub 2}Al{sub 5} layer. An attempt was also made to verify this effect through controlled experiments in a hot-dip galvanizing simulator and electron microscopic characterization of a few samples.

  2. Transfusion and blood donation in comic strips.

    Science.gov (United States)

    Lefrère, Jean-Jacques; Danic, Bruno

    2013-07-01

    The representation of blood transfusion and donation of blood in the comic strip has never been studied. The comic strip, which is a relatively recent art, emerged in the 19th century before becoming a mass medium during the 20th century. We have sought, by calling on collectors and using the resources of Internet, comic strips devoted, wholly or in part, to the themes of transfusion and blood donation. We present some of them here in chronologic order, indicating the title, country of origin, year of publication, and names of authors. The theme of the superhero using transfusion to transmit his virtues or his powers is repeated throughout the 20th century in North American comic strips. More recently, comic strips have been conceived from the outset with a promotional aim. They perpetuate positive images and are directed toward a young readership, wielding humor to reduce the fear of venipuncture. Few comic strips denounce the abuse of the commercialization of products derived from the human body. The image of transfusion and blood donation given by the comic strips is not to be underestimated because their readership is primarily children, some of whom will become blood donors. Furthermore, if some readers are transfused during their lives, the impact of a memory more or less conscious of these childhood readings may resurface, both in hopes and in fears. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Control of surface thermal scratch of strip in tandem cold rolling

    Science.gov (United States)

    Chen, Jinshan; Li, Changsheng

    2014-07-01

    The thermal scratch seriously affects the surface quality of the cold rolled stainless steel strip. Some researchers have carried out qualitative and theoretical studies in this field. However, there is currently a lack of research on effective forecast and control of thermal scratch defects in practical production, especially in tandem cold rolling. In order to establish precise mathematical model of oil film thickness in deformation zone, the lubrication in cold rolling process of SUS410L stainless steel strip is studied, and major factors affecting oil film thickness are also analyzed. According to the principle of statistics, mathematical model of critical oil film thickness in deformation zone for thermal scratch is built, with fitting and regression analytical method, and then based on temperature comparison method, the criterion for deciding thermal scratch defects is put forward. Storing and calling data through SQL Server 2010, a software on thermal scratch defects control is developed through Microsoft Visual Studio 2008 by MFC technique for stainless steel in tandem cold rolling, and then it is put into practical production. Statistics indicate that the hit rate of thermal scratch is as high as 92.38%, and the occurrence rate of thermal scratch is decreased by 89.13%. Owing to the application of the software, the rolling speed is increased by approximately 9.3%. The software developed provides an effective solution to the problem of thermal scratch defects in tandem cold rolling, and helps to promote products surface quality of stainless steel strips in practical production.

  4. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    Science.gov (United States)

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and

  5. Novel acyclonucleoside analog bearing a 1,2,4-triazole–Schiff base: Synthesis, characterization and analytical studies using square wave-adsorptive stripping voltammetry and HPLC

    Directory of Open Access Journals (Sweden)

    Ali F. Alghamdi

    2017-09-01

    Full Text Available New acyclonucleoside analogs tethered by a 1,2,4-triazole scaffold were synthesized through the condensation of 4-amino-5-(2-phenyleth-1-yl-2,4-dihydro-3H-1,2,4-triazole-3-thione (2 with benzaldehyde followed by the alkylation of the resulting Schiff base (3with 2-bromoethanol, 3-chloropropanol and/or 3-chloropropan-1,2-diol. Voltammetric studies were carried out for the analysis of 1 × 10−6 mol L−1 of the newly synthesized acyclonucleoside analogs (4–6 using square wave-adsorptive stripping voltammetry (SW-AdSV. The sharp voltammetric peak and high reduction current were recorded using a Britton–Robinson B–R pH 10 buffer at Ep = −1250 mV on the hanging mercury drop surface (HMDE and Ag/AgCl reference electrode. Several experimental conditions were studied, such as the supporting electrolytes, the pH, and the accumulation time, as well as the potential, the scan rate, the frequency and the step potential for 4-benzylideneamino-5-(2-phenyleth-1-yl-3-[(2,3-dihydroxyprop-1-ylthio]-1,2,4-triazole (6. The analytical performance of the voltammetric technique was investigated through the analysis of the calibration curve, the detection limit, the recovery and the stability. The voltammetric analytical applications were evaluated by the recovery of compound (6 in the urine and plasma samples. The HPLC technique was also applied for the separation of compound (6 from interference using a C-18 (5 μm column with UV detection at 254 nm.

  6. Development of floating strip micromegas detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, Jonathan

    2014-04-28

    Micromegas are high-rate capable, high-resolution micro-pattern gaseous detectors. Square meter sized resistive strip Micromegas are foreseen as replacement of the currently used precision tracking detectors in the Small Wheel, which is part of the forward region of the ATLAS muon spectrometer. The replacement is necessary to ensure tracking and triggering performance of the muon spectrometer after the luminosity increase of the Large Hadron Collider beyond its design value of 10{sup 34} cm{sup -2}s{sup -1} around 2020. In this thesis a novel discharge tolerant floating strip Micromegas detector is presented and described. By individually powering copper anode strips, the effects of a discharge are confined to a small region of the detector. This reduces the impact of discharges on the efficiency by three orders of magnitude, compared to a standard Micromegas. The physics of the detector is studied and discussed in detail. Several detectors are developed: A 6.4 x 6.4 cm{sup 2} floating strip Micromegas with exchangeable SMD capacitors and resistors allows for an optimization of the floating strip principle. The discharge behavior is investigated on this device in depth. The microscopic structure of discharges is quantitatively explained by a detailed detector simulation. A 48 x 50 cm{sup 2} floating strip Micromegas is studied in high energy pion beams. Its homogeneity with respect to pulse height, efficiency and spatial resolution is investigated. The good performance in high-rate background environments is demonstrated in cosmic muon tracking measurements with a 6.4 x 6.4 cm{sup 2} floating strip Micromegas under lateral irradiation with 550 kHz 20 MeV proton beams. A floating strip Micromegas doublet with low material budget is developed for ion tracking without limitations from multiple scattering in imaging applications during medical ion therapy. Highly efficient tracking of 20 MeV protons at particle rates of 550 kHz is possible. The reconstruction of the

  7. Development of floating strip micromegas detectors

    International Nuclear Information System (INIS)

    Bortfeldt, Jonathan

    2014-01-01

    Micromegas are high-rate capable, high-resolution micro-pattern gaseous detectors. Square meter sized resistive strip Micromegas are foreseen as replacement of the currently used precision tracking detectors in the Small Wheel, which is part of the forward region of the ATLAS muon spectrometer. The replacement is necessary to ensure tracking and triggering performance of the muon spectrometer after the luminosity increase of the Large Hadron Collider beyond its design value of 10 34 cm -2 s -1 around 2020. In this thesis a novel discharge tolerant floating strip Micromegas detector is presented and described. By individually powering copper anode strips, the effects of a discharge are confined to a small region of the detector. This reduces the impact of discharges on the efficiency by three orders of magnitude, compared to a standard Micromegas. The physics of the detector is studied and discussed in detail. Several detectors are developed: A 6.4 x 6.4 cm 2 floating strip Micromegas with exchangeable SMD capacitors and resistors allows for an optimization of the floating strip principle. The discharge behavior is investigated on this device in depth. The microscopic structure of discharges is quantitatively explained by a detailed detector simulation. A 48 x 50 cm 2 floating strip Micromegas is studied in high energy pion beams. Its homogeneity with respect to pulse height, efficiency and spatial resolution is investigated. The good performance in high-rate background environments is demonstrated in cosmic muon tracking measurements with a 6.4 x 6.4 cm 2 floating strip Micromegas under lateral irradiation with 550 kHz 20 MeV proton beams. A floating strip Micromegas doublet with low material budget is developed for ion tracking without limitations from multiple scattering in imaging applications during medical ion therapy. Highly efficient tracking of 20 MeV protons at particle rates of 550 kHz is possible. The reconstruction of the track inclination in a single

  8. 7 CFR 29.6128 - Straight Stripped (X Group).

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Straight Stripped (X Group). 29.6128 Section 29.6128... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.6128 Straight Stripped (X Group). This group consists of..., and tolerances X1 Fine Quality Straight Stripped. Heavy, ripe, firm, semielastic, normal strength and...

  9. Electrical performances of pyroelectric bimetallic strip heat engines describing a Stirling cycle

    Science.gov (United States)

    Arnaud, A.; Boughaleb, J.; Monfray, S.; Boeuf, F.; Cugat, O.; Skotnicki, T.

    2015-12-01

    This paper deals with the analytical modeling of pyroelectric bimetallic strip heat engines. These devices are designed to exploit the snap-through of a thermo-mechanically bistable membrane to transform a part of the heat flowing through the membrane into mechanical energy and to convert it into electric energy by means of a piezoelectric layer deposited on the surface of the bistable membrane. In this paper, we describe the properties of these heat engines in the case when they complete a Stirling cycle, and we evaluate the performances (available energy, Carnot efficiency...) of these harvesters at the macro- and micro-scale.

  10. Apparatus for measuring profile thickness of strip material

    International Nuclear Information System (INIS)

    Hold, A.C.

    1982-01-01

    Apparatus for measuring the thickness profile of steel strip comprises a radiation source reciprocally movable in a stepwise fashion (by a belt) across the strip width on one side thereof and a single elongated detector on the other side of the strip aligned with the scanning source. This detector may be a fluorescent scintillator detector or an ionisation chamber. Means are provided for sensing the degree of excitation in the detector in synchronism with the scanning source whereby to provide an output representative of the thickness profile of the strip. (author)

  11. Stability of barotropic vortex strip on a rotating sphere.

    Science.gov (United States)

    Sohn, Sung-Ik; Sakajo, Takashi; Kim, Sun-Chul

    2018-02-01

    We study the stability of a barotropic vortex strip on a rotating sphere, as a simple model of jet streams. The flow is approximated by a piecewise-continuous vorticity distribution by zonal bands of uniform vorticity. The linear stability analysis shows that the vortex strip becomes stable as the strip widens or the rotation speed increases. When the vorticity constants in the upper and the lower regions of the vortex strip have the same positive value, the inner flow region of the vortex strip becomes the most unstable. However, when the upper and the lower vorticity constants in the polar regions have different signs, a complex pattern of instability is found, depending on the wavenumber of perturbations, and interestingly, a boundary far away from the vortex strip can be unstable. We also compute the nonlinear evolution of the vortex strip on the rotating sphere and compare with the linear stability analysis. When the width of the vortex strip is small, we observe a good agreement in the growth rate of perturbation at an early time, and the eigenvector corresponding to the unstable eigenvalue coincides with the most unstable part of the flow. We demonstrate that a large structure of rolling-up vortex cores appears in the vortex strip after a long-time evolution. Furthermore, the geophysical relevance of the model to jet streams of Jupiter, Saturn and Earth is examined.

  12. Stability of barotropic vortex strip on a rotating sphere

    Science.gov (United States)

    Sohn, Sung-Ik; Sakajo, Takashi; Kim, Sun-Chul

    2018-02-01

    We study the stability of a barotropic vortex strip on a rotating sphere, as a simple model of jet streams. The flow is approximated by a piecewise-continuous vorticity distribution by zonal bands of uniform vorticity. The linear stability analysis shows that the vortex strip becomes stable as the strip widens or the rotation speed increases. When the vorticity constants in the upper and the lower regions of the vortex strip have the same positive value, the inner flow region of the vortex strip becomes the most unstable. However, when the upper and the lower vorticity constants in the polar regions have different signs, a complex pattern of instability is found, depending on the wavenumber of perturbations, and interestingly, a boundary far away from the vortex strip can be unstable. We also compute the nonlinear evolution of the vortex strip on the rotating sphere and compare with the linear stability analysis. When the width of the vortex strip is small, we observe a good agreement in the growth rate of perturbation at an early time, and the eigenvector corresponding to the unstable eigenvalue coincides with the most unstable part of the flow. We demonstrate that a large structure of rolling-up vortex cores appears in the vortex strip after a long-time evolution. Furthermore, the geophysical relevance of the model to jet streams of Jupiter, Saturn and Earth is examined.

  13. Voltammetric technique, a panacea for analytical examination of environmental samples

    International Nuclear Information System (INIS)

    Zahir, E.; Mohiuddin, S.; Naqvi, I.I.

    2012-01-01

    Voltammetric methods for trace metal analysis in environmental samples of marine origin like mangrove, sediments and shrimps are generally recommended. Three different electro-analytical techniques i.e. polarography, anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (ADSV) have been used. Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ and Mn/sub 2/+ were determined through ASV, Cr/sub 6/+ was analyzed by ADSV and Fe/sub 2/+, Zn/sub 2/+, Ni/sub 2/+ and Co/sub 2/+ were determined through polarography. Out of which pairs of Fe/sub 2/+Zn/sub 2/+ and Ni/sub 2/+Co/sub 2/+ were determined in two separate runs while Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ were analyzed in single run of ASV. Sensitivity and speciation capabilities of voltammetric methods have been employed. Analysis conditions were optimized that includes selection of supporting electrolyte, pH, working electrodes, sweep rate etc. Stripping voltammetry was adopted for analysis at ultra trace levels. Statistical parameters for analytical method development like selectivity factor, interference, repeatability (0.0065-0.130 macro g/g), reproducibility (0.08125-1.625 macro g/g), detection limits (0.032-5.06 macro g/g), limits of quantification (0.081-12.652 macro g/g), sensitivities (5.636-2.15 nA mL macro g-1) etc. were also determined. The percentage recoveries were found in between 95-105% using certified reference materials. Real samples of complex marine environment from Karachi coastline were also analyzed. The standard addition method was employed where any matrix effect was evidenced. (author)

  14. Integral relations in complex space and the global analytic and monodromic structure of Green's functions in quantum field theory

    International Nuclear Information System (INIS)

    Bros, J.

    1980-01-01

    In this lecture, we present some of the ideas of a global consistent approach to the analytic and monodromic structure of Green's functions and scattering amplitudes of elementary particles on the basis of general quantum field theory. (orig.)

  15. Hydraulic modeling of riverbank filtration systems with curved boundaries using analytic elements and series solutions

    Science.gov (United States)

    Bakker, Mark

    2010-08-01

    A new analytic solution approach is presented for the modeling of steady flow to pumping wells near rivers in strip aquifers; all boundaries of the river and strip aquifer may be curved. The river penetrates the aquifer only partially and has a leaky stream bed. The water level in the river may vary spatially. Flow in the aquifer below the river is semi-confined while flow in the aquifer adjacent to the river is confined or unconfined and may be subject to areal recharge. Analytic solutions are obtained through superposition of analytic elements and Fourier series. Boundary conditions are specified at collocation points along the boundaries. The number of collocation points is larger than the number of coefficients in the Fourier series and a solution is obtained in the least squares sense. The solution is analytic while boundary conditions are met approximately. Very accurate solutions are obtained when enough terms are used in the series. Several examples are presented for domains with straight and curved boundaries, including a well pumping near a meandering river with a varying water level. The area of the river bottom where water infiltrates into the aquifer is delineated and the fraction of river water in the well water is computed for several cases.

  16. Asteroid proper elements from an analytical second order theory

    International Nuclear Information System (INIS)

    Knezevic, Z.; Milani, A.

    1989-01-01

    The authors have computed by a fully analytical method a new set of proper elements for 3322 numbered main-belt asteroids. They are presented in the following format: asteroid number, proper semimajor axis (AU), proper eccentricity, sine of proper inclination and quality code (see below). This new set is significantly more accurate than all the previous ones at low to moderate eccentricities and inclinations, and especially near the main mean-motion resonances (e.g., the Themis region). This is because the short periodic perturbations are rigorously removed, and the main effects of the second-order (containing the square of the ratio [the mass of Jupiter/mass of the Sun]) are accounted for. Effects arising from the terms in the Hamiltonian of degree up to four in the eccentricity and inclination of both the asteroid and Jupiter are taken into account, and the fundamental frequencies g (for the perihelion) and s(for the node) of the asteroid are computed with a interative algorithm consistent with the basic results of modern dynamics (e.g., Kolmogorov-Arnold-Moser theory)

  17. Magnetic stripping studies for SPL

    CERN Document Server

    Posocco, P; CERN. Geneva. BE Department

    2010-01-01

    Magnetic stripping of H- can seriously enhance the beam losses along the SPL machine. These losses depend on the beam energy, on the beam transverse distribution and on the intensity of the magnetic field. For radioprotection issues the losses must be limited to 1 W/m. In this paper we will concentrate on the stripping phenomena inside the quadrupole magnets with the aim of defining the quadrupole range for the design phase of SPL.

  18. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  19. Microstructural research on hot strips of low carbon steel produced by a compact strip production line under different thermal histories

    International Nuclear Information System (INIS)

    Yu Hao; Chen Qixiang; Kang Yonglin; Sun Yi

    2005-01-01

    Coupons with the same composition and thickness (4.0 mm nominal gauge) obtained from hot strips of low carbon steel underwent a series of investigations to analyze the microstructural characteristics and mechanisms responsible for their differences in mechanical properties. Two different industrial technologies were adopted, although the strips used in this research were produced on the same Compact Strip Production (CSP) line. One of the strips was produced with a routine γ→α CSP thermal history, but the other with a γ→α→γ* conventional thermal history. The only difference between them was that one technology had a α→γ* thermal history. Different specimens of both types of strips were prepared for metallographic observation, tensile tests, electron back-scattered diffraction tests and positron annihilation technique tests. Experimental results showed that the differences in mechanical properties could be ascribed to dissimilarities not only in the grain size and textural components but also in dislocation density

  20. High Pressure Water Stripping Using Multi-Orifice Nozzles

    Science.gov (United States)

    Hoppe, David

    1999-01-01

    The use of multi-orifice rotary nozzles greatly increases the speed and stripping effectiveness of high pressure water blasting systems, but also greatly increases the complexity of selecting and optimizing the operating parameters. The rotational speed of the nozzle must be coupled with its transverse velocity as it passes across the surface of the substrate being stripped. The radial and angular positions of each orifice must be included in the analysis of the nozzle configuration. Orifices at the outer edge of the nozzle head move at a faster rate than the orifices located near the center. The energy transmitted to the surface from the impact force of the water stream from an outer orifice is therefore spread over a larger area than energy from an inner orifice. Utilizing a larger diameter orifice in the outer radial positions increases the total energy transmitted from the outer orifice to compensate for the wider distribution of energy. The total flow rate from the combination of all orifices must be monitored and should be kept below the pump capacity while choosing orifice to insert in each position. The energy distribution from the orifice pattern is further complicated since the rotary path of all the orifices in the nozzle head pass through the center section. All orifices contribute to the stripping in the center of the path while only the outer most orifice contributes to the stripping at the edge of the nozzle. Additional orifices contribute to the stripping from the outer edge toward the center section. With all these parameters to configure and each parameter change affecting the others, a computer model was developed to track and coordinate these parameters. The computer simulation graphically indicates the cumulative affect from each parameter selected. The result from the proper choices in parameters is a well designed, highly efficient stripping system. A poorly chosen set of parameters will cause the nozzle to strip aggressively in some areas

  1. Determination of tellurium in gallium by alternating current stripping voltammetry with a mercury/graphite electrode

    International Nuclear Information System (INIS)

    Berengard, I.B.; Kaplan, B. Ya.

    1986-01-01

    The analytical signal in ac stripping coltammetry (ACSV) with mercury indicator electrodes depends on the weight of the electrolytically collected analyte at the electrode surface, the depth of the collection layer being equal to the effective diffusion-layer thickness. Replacement of the static mercury drop electrode (SMDE) by the mercury/graphite electrode (MGE) is of practical interest in that the analyte detection limit can be lowered by decreasing the colume of the telluriumcontaining polarographed solution; in addition, plant laboratories find it difficult to control the SDME uniformity. The work in this article was done on a PU-1 universal polarograph in a square-wave vol tage component mode using the three-electrode cell shown. The rotating mercury/graphite electrode is found by the authors to be superior to the static mercury drop electrode in that it can lower the detection limit for tellurium in gallium to 5.10 /SUP -7percent/ , due to the smaller volume of the polarographed solution

  2. Causality and analyticity in optics

    International Nuclear Information System (INIS)

    Nussenzveig, H.M.

    In order to provide an overall picture of the broad range of optical phenomena that are directly linked with the concepts of causality and analyticity, the following topics are briefly reviewed, emphasizing recent developments: 1) Derivation of dispersion relations for the optical constants of general linear media from causality. Application to the theory of natural optical activity. 2) Derivation of sum rules for the optical constants from causality and from the short-time response function (asymptotic high-frequency behavior). Average spectral behavior of optical media. Applications. 3) Role of spectral conditions. Analytic properties of coherence functions in quantum optics. Reconstruction theorem.4) Phase retrieval problems. 5) Inverse scattering problems. 6) Solution of nonlinear evolution equations in optics by inverse scattering methods. Application to self-induced transparency. Causality in nonlinear wave propagation. 7) Analytic continuation in frequency and angular momentum. Complex singularities. Resonances and natural-mode expansions. Regge poles. 8) Wigner's causal inequality. Time delay. Spatial displacements in total reflection. 9) Analyticity in diffraction theory. Complex angular momentum theory of Mie scattering. Diffraction as a barrier tunnelling effect. Complex trajectories in optics. (Author) [pt

  3. An analytic analysis of the pion decay constant in three-flavoured chiral perturbation theory

    Energy Technology Data Exchange (ETDEWEB)

    Ananthanarayan, B.; Ghosh, Shayan [Indian Institute of Science, Centre for High Energy Physics, Bangalore, Karnataka (India); Bijnens, Johan [Lund University, Department of Astronomy and Theoretical Physics, Lund (Sweden)

    2017-07-15

    A representation of the two-loop contribution to the pion decay constant in SU(3) chiral perturbation theory is presented. The result is analytic up to the contribution of the three (different) mass sunset integrals, for which an expansion in their external momentum has been taken. We also give an analytic expression for the two-loop contribution to the pion mass based on a renormalized representation and in terms of the physical eta mass. We find an expansion of F{sub π} and M{sub π}{sup 2} in the strange-quark mass in the isospin limit, and we perform the matching of the chiral SU(2) and SU(3) low-energy constants. A numerical analysis demonstrates the high accuracy of our representation, and the strong dependence of the pion decay constant upon the values of the low-energy constants, especially in the chiral limit. Finally, we present a simplified representation that is particularly suitable for fitting with available lattice data. (orig.)

  4. Analytical energy gradients for explicitly correlated wave functions. I. Explicitly correlated second-order Møller-Plesset perturbation theory

    Science.gov (United States)

    Győrffy, Werner; Knizia, Gerald; Werner, Hans-Joachim

    2017-12-01

    We present the theory and algorithms for computing analytical energy gradients for explicitly correlated second-order Møller-Plesset perturbation theory (MP2-F12). The main difficulty in F12 gradient theory arises from the large number of two-electron integrals for which effective two-body density matrices and integral derivatives need to be calculated. For efficiency, the density fitting approximation is used for evaluating all two-electron integrals and their derivatives. The accuracies of various previously proposed MP2-F12 approximations [3C, 3C(HY1), 3*C(HY1), and 3*A] are demonstrated by computing equilibrium geometries for a set of molecules containing first- and second-row elements, using double-ζ to quintuple-ζ basis sets. Generally, the convergence of the bond lengths and angles with respect to the basis set size is strongly improved by the F12 treatment, and augmented triple-ζ basis sets are sufficient to closely approach the basis set limit. The results obtained with the different approximations differ only very slightly. This paper is the first step towards analytical gradients for coupled-cluster singles and doubles with perturbative treatment of triple excitations, which will be presented in the second part of this series.

  5. Computationally simple, analytic, closed form solution of the Coulomb self-interaction problem in Kohn Sham density functional theory

    International Nuclear Information System (INIS)

    Gonis, Antonios; Daene, Markus W.; Nicholson, Don M.; Stocks, George Malcolm

    2012-01-01

    We have developed and tested in terms of atomic calculations an exact, analytic and computationally simple procedure for determining the functional derivative of the exchange energy with respect to the density in the implementation of the Kohn Sham formulation of density functional theory (KS-DFT), providing an analytic, closed-form solution of the self-interaction problem in KS-DFT. We demonstrate the efficacy of our method through ground-state calculations of the exchange potential and energy for atomic He and Be atoms, and comparisons with experiment and the results obtained within the optimized effective potential (OEP) method.

  6. Direct determination of molybdenum in seawater by adsorption cathodic stripping square-wave voltammetry.

    Science.gov (United States)

    Sun, Y C; Mierzwa, J; Lan, C R

    2000-06-30

    A reliable and very sensitive procedure for the determination of trace levels of molybdenum in seawater is proposed. The complex of molybdenum with 8-hydroxyquinoline (Oxine) is analyzed by cathodic stripping square-wave voltammetry based on the adsorption collection onto a hanging mercury drop electrode (HMDE). This procedure of molybdenum determination was found to be more favorable than differential pulse cathodic stripping voltammetry because of inherently faster scan rate and much better linearity obtained through the one-peak (instead of one-of-two peaks) calibration. The variation of polarographic peak and peak current with a pH, adsorption time, adsorption potential, and some instrumental parameters such as scan rate and pulse height were optimized. The alteration of polarographic wave and its likely mechanism are also discussed. The relationship between peak current and molybdenum concentration is linear up to 150 mug l(-1). Under the optimal analytical conditions, the determination limit of 0.5 mug l(-1) Mo was reached after 60 s of the stirred collection. The estimated detection limit is better than 0.1 mug l(-1) of Mo. The applicability of this method to analysis of seawater was assessed by the determination of molybdenum in two certified reference seawater samples (CASS-2 and NASS-2) and the comparison of the analytical results for real seawater samples (study on a vertical distribution of Mo in the seawater column) with the results obtained by Zeeman-corrected electrothermal atomization atomic absorption spectrometry (Zeeman ETAAS). A good agreement between two used methods of molybdenum determination was obtained.

  7. Properties isotropy of magnesium alloy strip workpieces

    Directory of Open Access Journals (Sweden)

    Р. Кавалла

    2016-12-01

    Full Text Available The paper discusses the issue of obtaining high quality cast workpieces of magnesium alloys produced by strip roll-casting. Producing strips of magnesium alloys by combining the processes of casting and rolling when liquid melt is fed continuously to fast rolls is quite promising and economic. In the process of sheet stamping considerable losses of metal occur on festoons formed due to anisotropy of properties of foil workpiece, as defined by the macro- and microstructure and modes of rolling and annealing. The principal causes of anisotropic mechanical properties of metal strips produced by the combined casting and rolling technique are the character of distribution of intermetallic compounds in the strip, orientation of phases of metal defects and the residual tensions. One of the tasks in increasing the output of fit products during stamping operations consists in minimizing the amount of defects. To lower the level of anisotropy in mechanical properties various ways of treating the melt during casting are suggested. Designing the technology of producing strips of magnesium alloys opens a possibility of using them in automobile industry to manufacture light-weight body elements instead of those made of steel.

  8. Analytical chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Myeong Hu; Lee, Hu Jun; Kim, Ha Seok

    1989-02-15

    This book give explanations on analytical chemistry with ten chapters, which deal with development of analytical chemistry, the theory of error with definition and classification, sample and treatment gravimetry on general process of gravimetry in aqueous solution and non-aqueous solution, precipitation titration about precipitation reaction and types, complexometry with summary and complex compound, oxidation-reduction equilibrium on electrode potential and potentiometric titration, solvent extraction and chromatograph and experiment with basic operation for chemical experiment.

  9. Analytical chemistry

    International Nuclear Information System (INIS)

    Chae, Myeong Hu; Lee, Hu Jun; Kim, Ha Seok

    1989-02-01

    This book give explanations on analytical chemistry with ten chapters, which deal with development of analytical chemistry, the theory of error with definition and classification, sample and treatment gravimetry on general process of gravimetry in aqueous solution and non-aqueous solution, precipitation titration about precipitation reaction and types, complexometry with summary and complex compound, oxidation-reduction equilibrium on electrode potential and potentiometric titration, solvent extraction and chromatograph and experiment with basic operation for chemical experiment.

  10. Analytical determination of size-dependent natural frequencies of fully clamped rectangular microplates based on the modified couple stress theory

    Energy Technology Data Exchange (ETDEWEB)

    Askari, Amir R.; Tahani, Masoud [Ferdowsi University of Mashhad, Mashhad (Iran, Islamic Republic of)

    2015-05-15

    This paper presents an analytical and size-dependent model for vibrational analysis of fully clamped rectangular microplates. Modified couple stress theory (MCST) and the Kirchhoff plate model are considered, and Hamilton's principle is employed to derive the size dependent equation of motion that accounts for the effect of residual stresses. The natural frequencies of the microplate are extracted analytically by extended Kantorovich method. The present findings are validated with the available results in the literature, and an excellent agreement is observed between them. In addition, a parametric study is conducted to demonstrate the significant effects of couple stress components on the natural frequencies of fully clamped microplates. The ratio of MCST natural frequencies to those obtained with classical theory depends only on the Poisson's ratio of the plate and is independent of the aspect ratio of the plate for cases with no residual stresses.

  11. Analytical determination of size-dependent natural frequencies of fully clamped rectangular microplates based on the modified couple stress theory

    International Nuclear Information System (INIS)

    Askari, Amir R.; Tahani, Masoud

    2015-01-01

    This paper presents an analytical and size-dependent model for vibrational analysis of fully clamped rectangular microplates. Modified couple stress theory (MCST) and the Kirchhoff plate model are considered, and Hamilton's principle is employed to derive the size dependent equation of motion that accounts for the effect of residual stresses. The natural frequencies of the microplate are extracted analytically by extended Kantorovich method. The present findings are validated with the available results in the literature, and an excellent agreement is observed between them. In addition, a parametric study is conducted to demonstrate the significant effects of couple stress components on the natural frequencies of fully clamped microplates. The ratio of MCST natural frequencies to those obtained with classical theory depends only on the Poisson's ratio of the plate and is independent of the aspect ratio of the plate for cases with no residual stresses.

  12. Evaluation of silicon micro strip detectors with large read-out pitch

    International Nuclear Information System (INIS)

    Senyo, K.; Yamamura, K.; Tsuboyama, T.; Avrillon, S.; Asano, Y.; Bozek, A.; Natkaniec, Z.; Palka, H.; Rozanska, M.; Rybicki, K.

    1996-01-01

    For the development of the silicon micro-strip detector with the pitch of the readout strips as large as 250 μm on the ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips. (orig.)

  13. Covalent immobilization of lipase, glycerol kinase, glycerol-3-phosphate oxidase & horseradish peroxidase onto plasticized polyvinyl chloride (PVC strip & its application in serum triglyceride determination

    Directory of Open Access Journals (Sweden)

    Nidhi Chauhan

    2014-01-01

    Full Text Available Background & objectives:Reusable biostrip consisting enzymes immobilized onto alkylamine glass beads affixed on plasticized PVC strip for determination of triglyceride (TG suffers from high cost of beads and their detachments during washings for reuse, leading to loss of activity. The purpose of this study was to develop a cheaper and stable biostrip for investigation of TG levels in serum. Methods: A reusable enzyme-strip was prepared for TG determination by co-immobilizing lipase, glycerol kinase (GK, glycerol-3-phosphate oxidase (GPO and peroxidase (HRP directly onto plasticized polyvinyl chloride (PVC strip through glutaraldehyde coupling. The method was evaluated by studying its recovery, precision and reusability. Results: The enzyme-strip showed optimum activity at pH 7.0, 35 o C and a linear relationship between its activity and triolein concentration in the range 0.1 to 15 mM. The strip was used for determination of serum TG. The detection limit of the method was 0.1 mM. Analytical recovery of added triolein was 96 per cent. Within and between batch coefficients of variation (CV were 2.2 and 3.7 per cent, respectively. A good correlation (r=0.99 was found between TG values by standard enzymic colrimetric method employing free enzymes and the present method. The strip lost 50 per cent of its initial activity after its 200 uses during the span of 100 days, when stored at 4 o C. Interpretation & conclusions: The nitrating acidic treatment of plasticized PVC strip led to glutaraldehyde coupling of four enzymes used for enzymic colourimetric determination of serum TG. The strip provided 200 reuses of enzymes with only 50 per cent loss of its initial activity. The method could be used for preparation of other enzyme strips also.

  14. From divergent power series to analytic functions theory and application of multisummable power series

    CERN Document Server

    Balser, Werner

    1994-01-01

    Multisummability is a method which, for certain formal power series with radius of convergence equal to zero, produces an analytic function having the formal series as its asymptotic expansion. This book presents the theory of multisummabi- lity, and as an application, contains a proof of the fact that all formal power series solutions of non-linear meromorphic ODE are multisummable. It will be of use to graduate students and researchers in mathematics and theoretical physics, and especially to those who encounter formal power series to (physical) equations with rapidly, but regularly, growing coefficients.

  15. Micro-strip sensors based on CVD diamond

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D' Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D. E-mail: dirk.meier@cern.ch; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M

    2000-10-11

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  16. Micro-strip sensors based on CVD Diamond

    CERN Document Server

    Adam, W; Bergonzo, P; Bertuccio, G; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; D'Angelo, P; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Hallewell, G D; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Koeth, T W; Krammer, Manfred; Lo Giudice, A; Lü, R; MacLynne, L; Manfredotti, C; Meier, D; Mishina, M; Moroni, L; Oh, A; Pan, L S; Pernicka, Manfred; Peitz, A; Perera, L P; Pirollo, S; Procario, M; Riester, J L; Roe, S; Rousseau, L; Rudge, A; Russ, J; Sala, S; Sampietro, M; Schnetzer, S R; Sciortino, S; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R J; Trischuk, W; Tromson, D; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; Wetstein, M; White, C; Zeuner, W; Zoeller, M M

    2000-01-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  17. Micro-strip sensors based on CVD diamond

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.

    2000-01-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation

  18. Micro-strip sensors based on CVD diamond

    Science.gov (United States)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; RD42 Collaboration

    2000-10-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  19. Membrane air stripping utilizing a plate and frame configuration

    International Nuclear Information System (INIS)

    Boswell, S.T.

    1991-01-01

    Membrane air stripping has recently been proposed as a possible method to remove volatile organic chemicals (VOCs) and radon from drinking water supplies. Current and anticipated regulatory requirements, driven by health consequences, make the removal of these contaminants mandatory. This work examines the use of plate and frame membrane air stripping for the removal of VOCs and radon from a water supply. The theoretical basis of membrane air stripping and a literature review are included. The advantages of membrane air stripping versus other methods of removal, as well as the advantages of a plate and frame configuration versus a hollow fiber configuration for membrane air stripping are discussed. Multiple regression/correlation techniques are used to model mass transfer coefficients and fluid resistances. An economic evaluation is performed using the developed models. The costs of comparable membrane and packed tower air stripping systems are 4.86 cents per thousand gallons versus 4.36 cents per thousand gallons, respectively. This work indicates that plate and frame membrane air stripping may, in fact, prove to be an economical alternative to packed tower aeration and carbon adsorption for the removal of VOCs and radon

  20. Advection endash diffusion past a strip. II. Oblique incidence

    International Nuclear Information System (INIS)

    Knessl, C.; Keller, J.B.

    1997-01-01

    Advection and diffusion of particles past an impenetrable strip is considered when the strip is oblique to the advection or drift velocity. The particle concentration p(x,y) is determined asymptotically for large values of vL/D, where v is the drift velocity, D is the diffusion coefficient, and 2L is the width of the strip. The results complement those of Part I, which treated a strip normal to the drift velocity. copyright 1997 American Institute of Physics

  1. Stripping of uranium from Dehpa/kerosene solvents by different aqueous media

    International Nuclear Information System (INIS)

    Khorfan, S.; Stas, J.; Kassem, M.

    1998-01-01

    Stripping uranium from Dehpa/kerosene solvent is a crucial step in the recovery of uranium. Stripping was studied using different stripping media mainly ammonium carbonate, phosphoric acid, sulfuric acid, hydrochloric acid and nitric acid. Stripping was measured at different operating conditions such as aqueous concentrations, temperatures, and Dehpa/kerosene concentrations. The results obtained showed that stripping by acid media increases with the acid concentration and follows the order: HF > H 3 PO 4 > H 2 SO 4 > HCl > HNO 3 . To achieve higher stripping by phosphoric acid it was found necessary to increase the temperature to 50 deg C, the acid concentration to 5 mol/l and to reduce the uranium to U 4+ . Stripping by basic media was found to increase with increasing concentration of the stripping media and to follow the order: Na 2 CO 3 > (NH 4 ) 2 CO 3 > NH 4 HCO 3 . Stripping by ammonium carbonate was found to increase with temperature and carbonate concentration. The stripping was optimized at 0.5 mol/l carbonate concentration and at a temperature of 50 deg C. Stripping was decreased by increasing concentration of Dehpa in kerosene and was depressed more by adding the synergant Topo to the Dehpa solvent especially at 1/4 mol/mol ratio. (author)

  2. Calculation of the Strip Foundation on Solid Elastic Base, Taking into Account the Karst Collapse

    Science.gov (United States)

    Sharapov, R.; Lodigina, N.

    2017-07-01

    Karst processes greatly complicate the construction and operation of buildings and structures. Due to the karstic deformations at different times there have been several major accidents, which analysis showed that in all cases the fundamental errors committed at different stages of building development: site selection, engineering survey, design, construction or operation of the facilities. Theory analysis of beams on elastic foundation is essential in building practice. Specialist engineering facilities often have to resort to multiple designing in finding efficient forms of construction of these facilities. In work the calculation of stresses in cross-sections of the strip foundation evenly distributed load in the event of karst. A comparison of extreme stress in the event of karst and without accounting for the strip foundation as a beam on an elastic foundation.

  3. Analytical transport network theory to guide the design of 3-D microstructural networks in energy materials: Part 1. Flow without reactions

    Science.gov (United States)

    Cocco, Alex P.; Nakajo, Arata; Chiu, Wilson K. S.

    2017-12-01

    We present a fully analytical, heuristic model - the "Analytical Transport Network Model" - for steady-state, diffusive, potential flow through a 3-D network. Employing a combination of graph theory, linear algebra, and geometry, the model explicitly relates a microstructural network's topology and the morphology of its channels to an effective material transport coefficient (a general term meant to encompass, e.g., conductivity or diffusion coefficient). The model's transport coefficient predictions agree well with those from electrochemical fin (ECF) theory and finite element analysis (FEA), but are computed 0.5-1.5 and 5-6 orders of magnitude faster, respectively. In addition, the theory explicitly relates a number of morphological and topological parameters directly to the transport coefficient, whereby the distributions that characterize the structure are readily available for further analysis. Furthermore, ATN's explicit development provides insight into the nature of the tortuosity factor and offers the potential to apply theory from network science and to consider the optimization of a network's effective resistance in a mathematically rigorous manner. The ATN model's speed and relative ease-of-use offer the potential to aid in accelerating the design (with respect to transport), and thus reducing the cost, of energy materials.

  4. Stage- vs. Channel-strip Metaphor

    DEFF Research Database (Denmark)

    Gelineck, Steven; Korsgaard, Dannie Michael; Büchert, Morten

    2015-01-01

    This study compares the stage metaphor and the channel strip metaphor in terms of performance. Traditionally, music mixing consoles employ a channels strip control metaphor for adjusting parameters such as volume and panning of each track. An alternative control metaphor, the so-called stage meta...... is surprisingly similar and thus we are not able to detect any significant difference in performance between the two interfaces. Qualitative data however, suggests that the stage metaphor is largely favoured for its intuitive interaction - confirming earlier studies....

  5. Nafion/2,2'-bipyridyl-modified bismuth film electrode for anodic stripping voltammetry

    International Nuclear Information System (INIS)

    Torma, Ferenc; Kadar, Mihaly; Toth, Klara; Tatar, Eniko

    2008-01-01

    This paper describes the fabrication, characterisation and the application of a Nafion/2,2'-bipyridyl/bismuth composite film-coated glassy carbon electrode (NC(Bpy)BiFE) for the anodic stripping voltammetric determination of trace metal ions (Zn 2+ , Cd 2+ and Pb 2+ ). The NC(Bpy)BiFE electrode is prepared by first applying a 2.5 mm 3 drop of a coating solution containing 0.5 wt% Nafion and 0.1% (w/v) 2,2'-bipyridil (Bpy) onto the surface of a glassy carbon electrode, while the Bi film was plated in situ simultaneously with the target metal ions at -1.4 V. The main advantage of the polymer coated bismuth film electrode is that the sensitivity of the stripping responses is increased considerably due to the incorporation of the neutral chelating agent of 2,2'-bipyridyl (Bpy) in the Nafion film, while the Nafion coating improved the mechanical stability of the bismuth film and its resistance to the interference of surfactants. The key experimental parameters relevant to both the electrode fabrication and the voltammetric measurement were optimized on the basis of the stripping signals. With a 2 min deposition time in the presence of oxygen, linear calibration curves were obtained in a wide concentration range (about 2-0.001 μM) with detection limits of 8.6 nM (0.56 μg dm -3 ) for Zn 2+ , 1.1 nM (0.12 μg dm -3 ) for Cd 2+ and 0.37 nM (0.077 μg dm -3 ) for Pb 2+ . For nine successive preconcentration/determination/electrode renewal experiments the standard deviations were between 3 and 5% at 1.2 μM for zinc and 0.3-0.3 μM concentration level for lead and cadmium, respectively, and the method exhibited excellent selectivity in the presence of the excess of several potential interfering metal ions. The analytical utility of the stripping voltammetric method elaborated was tested in the assay of heavy metals in some real samples and the method was validated by ICP-MS technique

  6. Analytic number theory an introductory course

    CERN Document Server

    Bateman, Paul T

    2004-01-01

    This valuable book focuses on a collection of powerful methods ofanalysis that yield deep number-theoretical estimates. Particularattention is given to counting functions of prime numbers andmultiplicative arithmetic functions. Both real variable ("elementary")and complex variable ("analytic") methods are employed.

  7. Laser assisted self-pierce riveting of AZ31 magnesium alloy strips

    International Nuclear Information System (INIS)

    Durandet, Y.; Deam, R.; Beer, A.; Song, W.; Blacket, S.

    2010-01-01

    Laser assisted self-piercing riveting (LSPR) is a new solid state process that enables low ductility materials to be mechanically joined without cracking. A simple but effective thermal analysis of LSPR is presented that enabled both the absorption of the laser radiation and heat transfer between plies to be determined. The approach was applied to experimental data for LSPR joining of AZ31B-H24 magnesium alloy sheets. It is shown that by using this analytical approach, the temperature at the onset of joining could be estimated and related to observations of joint quality. It was found that crack-free joints were produced at strip temperatures above 200 o C at the time of rivet insertion.

  8. Moving Griffith crack in an orthotropic strip with punches at boundary faces

    Directory of Open Access Journals (Sweden)

    S. Mukherjee

    2005-01-01

    Full Text Available Integral transform technique is employed to solve the elastodynamic problem of steady-state propagation of a Griffith crack centrally situated along the midplane of orthotropic strip of finite thickness 2h and subjected to point loading with centrally situated moving punches under constant pressure along the boundaries of the layer. The problem is reduced to the solution of a pair of simultaneous singular integral equations with Cauchy-type singularities which have finally been solved through the finite Hilbert transform technique. For large h, analytical expression for the stress intensity factor at the crack tip is obtained. Graphical plots of the numerical results are also presented.

  9. Representation of Aloneness in Forever Alone Guy Comic Strips

    Directory of Open Access Journals (Sweden)

    Pricillia Chandra

    2017-01-01

    Full Text Available This study aims to discuss the representation of aloneness in Forever Alone Guy comic strips. The purpose of this research is to find out how the meaning of aloneness is constructed in the representation of Forever Alone Guy through the theory of representation described by Stuart Hall (1997, 2013. In the theory suggested by Hall, it is described that there are two ways to be done in creating representation. Those ways are through language/sign and mental representation. The mental representation is the only way used in this research with a reason that this analysis focuses to the stigmas attached to the concept of aloneness. The analysis shows that the construction of meaning is done through embedding clusters of negative stigmas to the three entities: single, alone and lonely. Thus, through the analysis, it can be concluded that the dominant meaning which represents being single and alone as the ‘imperfect’ condition plays an important role in the construction of the meaning

  10. Study of inter-strip gap effects and efficiency for full energy detection of double sided silicon strip detectors

    International Nuclear Information System (INIS)

    Fisichella, M.; Forneris, J.; Grassi, L.

    2015-01-01

    We performed a characterization of Double Sided Silicon Strip Detectors (DSSSD) with the aim to carry out a systematic study of the inter-strip effects on the energy measurement of charged particles. The dependence of the DSSSD response on ion, energy and applied bias has been investigated. (author)

  11. Detection of trace levels of Pb2+ in tap water at boron-doped diamond electrodes with anodic stripping voltammetry

    International Nuclear Information System (INIS)

    Dragoe, Diana; Spataru, Nicolae; Kawasaki, Ryuji; Manivannan, Ayyakkannu; Spataru, Tanta; Tryk, Donald A.; Fujishima, Akira

    2006-01-01

    Boron-doped diamond (BDD) electrodes were used to investigate the possibility of detecting trace levels of lead by linear-sweep anodic stripping voltammetry. The low limit of detection (2 nM) is an advantage compared to other electrode materials, and it was found that at low pH values, copper concentrations that are usually present in drinking water do not affect to a large extent the detection of lead. These findings recommend anodic stripping voltammetry at the BDD electrodes as a suitable mercury-free method for the determination of trace levels of lead in drinking water. The results obtained for the lead detection in tap water real samples are in excellent agreement with those found by inductively coupled plasma-mass spectrometry (ICP-MS), demonstrating the practical analytical utility of the method

  12. Stripping of uranium from Dehpa/Kerosene solvents by different aqueous media

    International Nuclear Information System (INIS)

    Khorfan, S.; Stas, J.; Kassem, M.

    2000-01-01

    Stripping uranium from Dehpa/kerosene solvent is a crucial step in the recovery of uranium. Stripping was studied using different stripping media mainly ammonium carbonate, phosphoric acid, sulfuric acid, hydrochloric acid and nitric acid. Stripping was measured at different operating conditions such as aqueous concentrations, temperatures, and Dehpa/kerosene concentrations. The results obtained showed that stripping by acid media increases with the acid concentration and follows the order: HF > H sub 3 Po sub 4 > H sub 2 S O sub 4 > HCl > HNO sub 3. To achieve higher stripping by phosphoric acid it was found necessary to increase the temperature to 50 deg C, the acid concentration to 5 mol/l and to reduce the uranium to U sup 4 sup +. Stripping by basic media was found to increase with increasing concentration of the stripping media and to follow the order: Na sub 2 CO sub 3 > (NH sub 4) sub 2 CO sub 3 > NH sub 4 HCO sub 3. Stripping by ammonium carbonate was found to increase with temperature and carbonate concentration. The stripping was optimized at 0.5 mol/l carbonate concentration and at a temperature of 50 deg C. Stripping was decreased by increasing concentration of Dehpa in kerosene and was depressed more by adding the synergant TOPO to the Dehpa solvent especially at 1/4 mol/mol ratio. (author)

  13. Strip defect recognition in electrical tests of silicon microstrip sensors

    Energy Technology Data Exchange (ETDEWEB)

    Valentan, Manfred, E-mail: valentan@mpp.mpg.de

    2017-02-11

    This contribution describes the measurement procedure and data analysis of AC-coupled double-sided silicon microstrip sensors with polysilicon resistor biasing. The most thorough test of a strip sensor is an electrical measurement of all strips of the sensor; the measured observables include e.g. the strip's current and the coupling capacitance. These measurements are performed to find defective strips, e.g. broken capacitors (pinholes) or implant shorts between two adjacent strips. When a strip has a defect, its observables will show a deviation from the “typical value”. To recognize and quantify certain defects, it is necessary to determine these typical values, i.e. the values the observables would have without the defect. As a novel approach, local least-median-of-squares linear fits are applied to determine these “would-be” values of the observables. A least-median-of-squares fit is robust against outliers, i.e. it ignores the observable values of defective strips. Knowing the typical values allows to recognize, distinguish and quantify a whole range of strip defects. This contribution explains how the various defects appear in the data and in which order the defects can be recognized. The method has been used to find strip defects on 30 double-sided trapezoidal microstrip sensors for the Belle II Silicon Vertex Detector, which have been measured at the Institute of High Energy Physics, Vienna (Austria).

  14. Strip type radiation detector and method of making same

    International Nuclear Information System (INIS)

    Jantsch, O.; Feigt, I.; Willig, W.R.

    1976-01-01

    An improved strip detector and a method for making such a detector in which a high resistivity N conduction semiconductor body has electrode strips formed thereon by diffusion is described. The strips are formed so as to be covered by an oxide layer at the surface point of the PN junction and in which the opposite side of the semiconductor body then has a substantial amount of material etched away to form a thin semiconductor upon which strip electrodes which are perpendicular to the electrodes on the first side are then placed

  15. Stripping voltammetry in environmental and food analysis.

    Science.gov (United States)

    Brainina, K Z; Malakhova, N A; Stojko, N Y

    2000-10-01

    The review covers over 230 papers published mostly in the last 5 years. The goal of the review is to attract the attention of researchers and users to stripping voltammetry in particular, its application in environmental monitoring and analysis of foodstuffs. The sensors employed are impregnated graphite, carbon paste, thick film carbon/graphite and thin film metallic electrodes modified in-situ or beforehand. Hanging mercury drop electrodes and mercury coated glassy carbon electrodes are also mentioned. Strip and long-lived sensors for portable instruments and flow through systems are discussed as devices for future development and application of stripping voltammetry.

  16. Characteristic effects of stochastic oscillatory forcing on neural firing: analytical theory and comparison to paddlefish electroreceptor data.

    Science.gov (United States)

    Bauermeister, Christoph; Schwalger, Tilo; Russell, David F; Neiman, Alexander B; Lindner, Benjamin

    2013-01-01

    Stochastic signals with pronounced oscillatory components are frequently encountered in neural systems. Input currents to a neuron in the form of stochastic oscillations could be of exogenous origin, e.g. sensory input or synaptic input from a network rhythm. They shape spike firing statistics in a characteristic way, which we explore theoretically in this report. We consider a perfect integrate-and-fire neuron that is stimulated by a constant base current (to drive regular spontaneous firing), along with Gaussian narrow-band noise (a simple example of stochastic oscillations), and a broadband noise. We derive expressions for the nth-order interval distribution, its variance, and the serial correlation coefficients of the interspike intervals (ISIs) and confirm these analytical results by computer simulations. The theory is then applied to experimental data from electroreceptors of paddlefish, which have two distinct types of internal noisy oscillators, one forcing the other. The theory provides an analytical description of their afferent spiking statistics during spontaneous firing, and replicates a pronounced dependence of ISI serial correlation coefficients on the relative frequency of the driving oscillations, and furthermore allows extraction of certain parameters of the intrinsic oscillators embedded in these electroreceptors.

  17. Twist-2 at seven loops in planar N=4 SYM theory: full result and analytic properties

    Energy Technology Data Exchange (ETDEWEB)

    Marboe, Christian [School of Mathematics, Trinity College Dublin,College Green, Dublin 2 (Ireland); Institut für Mathematik und Institut für Physik, Humboldt-Universität zu Berlin,IRIS Adlershof, Zum Großen Windkanal 6, 12489 Berlin (Germany); Velizhanin, Vitaly [Theoretical Physics Division, NRC “Kurchatov Institute”,Petersburg Nuclear Physics Institute, Orlova Roscha,Gatchina, 188300 St. Petersburg (Russian Federation); Institut für Mathematik und Institut für Physik, Humboldt-Universität zu Berlin,IRIS Adlershof, Zum Großen Windkanal 6, 12489 Berlin (Germany)

    2016-11-04

    The anomalous dimension of twist-2 operators of arbitrary spin in planar N=4 SYM theory is found at seven loops by using the quantum spectral curve to compute values at fixed spin, and reconstructing the general result using the LLL-algorithm together with modular arithmetic. The result of the analytic continuation to negative spin is presented, and its relation with the recently computed correction to the BFKL and double-logarithmic equation is discussed.

  18. Comparsion of an immunochromatographic strip with ELISA for simultaneous detection of thiamphenicol, florfenicol and chloramphenicol in food samples.

    Science.gov (United States)

    Guo, Lingling; Song, Shanshan; Liu, Liqiang; Peng, Juan; Kuang, Hua; Xu, Chuanlai

    2015-09-01

    Rapid and sensitive indirect competitive enzyme-linked immunosorbent assays (ic-ELISA) and gold nanoparticle immunochromatographic strip tests were developed to detect thiamphenicol (TAP), florfenicol (FF) and chloramphenicol (CAP) in milk and honey samples. The generic monoclonal antibody for TAP, FF and CAP was prepared based on a hapten [D-threo-1-(4-aminophenyl)-2- dichloroacetylamino-1,3-propanediol], and the haptenwas linked to a carrier protein using the diazotization method. After the optimization of several parameters (coating, pH, sodium chloride content and methanol content), the ic-ELISA was established. The quantitative working range for TAP was 0.11-1.36 ng/mL, with an IC50 of 0.39 ng/mL. The optimized ELISA showed cross-reactivity to CAP (300%) and FF (15.6%), with IC50 values of 0.13 and 2.5 ng/mL, respectively. The analytical recovery of TAP, FF and CAP in milk and honey samples in the ic-ELISA ranged from 81.2 to 112.9%. Based on this monoclonal antibody, a rapid and sensitive immunochromatographic test strip was also developed. This strip had a detection limit of 1 ng/mL for TAP, FF and CAP in milk and honey samples. Moreover, the test was completed within 10 min. Our results showed that the proposed ic-ELISA and immunochromatographic test strip method are highly useful screening tools for TAP, FF and CAP detection in milk and honey samples. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Hermeneutical and analytical jurisprudence

    Directory of Open Access Journals (Sweden)

    Spaić Bojan

    2014-01-01

    Full Text Available The article examines the main strands of development in jurisprudence in the last few decades from the standpoint of the metatheoretical differentiation between analytical and hermeneutical perspective in the study of law. The author claims that recent jurisprudent accounts can rarely be positioned within the traditional dichotomy natural law theories - legal positivism, and that this dichotomy is not able to account for the differences between contemporary conceptions of law. As an alternative the difference between the analytical and hermeneutical traditions in philosophy are explained, as they have crucially influenced posthartian strands in Anglo-American philosophy and postkelsenian strands in continental philosophy of law. Finally, the influence of hermeneutical philosophy and legal theory is examined in regards of the development of a hermeneutical theory of law and the development of legal hermeneutics.

  20. Collisional stripping of planetary crusts

    Science.gov (United States)

    Carter, Philip J.; Leinhardt, Zoë M.; Elliott, Tim; Stewart, Sarah T.; Walter, Michael J.

    2018-02-01

    Geochemical studies of planetary accretion and evolution have invoked various degrees of collisional erosion to explain differences in bulk composition between planets and chondrites. Here we undertake a full, dynamical evaluation of 'crustal stripping' during accretion and its key geochemical consequences. Crusts are expected to contain a significant fraction of planetary budgets of incompatible elements, which include the major heat producing nuclides. We present smoothed particle hydrodynamics simulations of collisions between differentiated rocky planetesimals and planetary embryos. We find that the crust is preferentially lost relative to the mantle during impacts, and we have developed a scaling law based on these simulations that approximates the mass of crust that remains in the largest remnant. Using this scaling law and a recent set of N-body simulations of terrestrial planet formation, we have estimated the maximum effect of crustal stripping on incompatible element abundances during the accretion of planetary embryos. We find that on average approximately one third of the initial crust is stripped from embryos as they accrete, which leads to a reduction of ∼20% in the budgets of the heat producing elements if the stripped crust does not reaccrete. Erosion of crusts can lead to non-chondritic ratios of incompatible elements, but the magnitude of this effect depends sensitively on the details of the crust-forming melting process on the planetesimals. The Lu/Hf system is fractionated for a wide range of crustal formation scenarios. Using eucrites (the products of planetesimal silicate melting, thought to represent the crust of Vesta) as a guide to the Lu/Hf of planetesimal crust partially lost during accretion, we predict the Earth could evolve to a superchondritic 176Hf/177Hf (3-5 parts per ten thousand) at present day. Such values are in keeping with compositional estimates of the bulk Earth. Stripping of planetary crusts during accretion can lead to

  1. Toward an integrative theory of training motivation: a meta-analytic path analysis of 20 years of research.

    Science.gov (United States)

    Colquitt, J A; LePine, J A; Noe, R A

    2000-10-01

    This article meta-analytically summarizes the literature on training motivation, its antecedents, and its relationships with training outcomes such as declarative knowledge, skill acquisition, and transfer. Significant predictors of training motivation and outcomes included individual characteristics (e.g., locus of control, conscientiousness, anxiety, age, cognitive ability, self-efficacy, valence, job involvement) and situational characteristics (e.g., climate). Moreover, training motivation explained incremental variance in training outcomes beyond the effects of cognitive ability. Meta-analytic path analyses further showed that the effects of personality, climate, and age on training outcomes were only partially mediated by self-efficacy, valence, and job involvement. These findings are discussed in terms of their practical significance and their implications for an integrative theory of training motivation.

  2. Answer First: Applying the Heuristic-Analytic Theory of Reasoning to Examine Student Intuitive Thinking in the Context of Physics

    Science.gov (United States)

    Kryjevskaia, Mila; Stetzer, MacKenzie R.; Grosz, Nathaniel

    2014-01-01

    We have applied the heuristic-analytic theory of reasoning to interpret inconsistencies in student reasoning approaches to physics problems. This study was motivated by an emerging body of evidence that suggests that student conceptual and reasoning competence demonstrated on one task often fails to be exhibited on another. Indeed, even after…

  3. New Concept of Cultivation Using Limited Strip-Tillage with Strip Shallow Irrigation

    Directory of Open Access Journals (Sweden)

    Yazid Ismi Intara

    2014-04-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE Dry land is one of land resources which potentially used for food crop cultivation, especially in the areas which have light to medium technical obstacles. The development of technology to improve soil quality in marginal lands to be productive lands is still widely open for agricultural development in Indonesia. Rooting medium quality can be improved by changing soil tillage method and observing the proper crop irrigation technology. It can be the solution for crop cultivation in clay loam soil. This study aimed to obtain water movement model in a minimally-tilled clay soil with strip shallow irrigation. The concept is limited soil-tillage with strip shallow irrigation method, water supply technique, and crop water requirement. Method used in this study includes developing water movement model (software development in a minimally-tilled clay soil with subsurface irrigation. In the final stages, research also conducted water movement analysis testing apparatus in the laboratory, field validation of the subsurface irrigation performance, and cultivation technique testing to chili pepper growth (Capsicum annuumL.. The development of water movement simulation on a limited strip-tillage with subsurface irrigation uses the concept to quantify the amount of water in the soil. The analysis of movement pattern was demonstrated on contour patterns. It showed that the wetting process can reach depth zone – 5 cm to the rooting zone. It was an important discovery on the development of minimum stripe tillage soil with subsurface irrigation. Specifically, it can be concluded that: the result of fitting by eyes to diffusivity graphic and water content obtained the required parameter values for soil physical properties. It was then simulated on horizontal water movement model on a minimum strip-tillage with strip shallow irrigation /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso

  4. Scattering of a light wave by a thin fiber on or near a prism: experiment and analytical theory.

    Science.gov (United States)

    Tajima, Fumiaki; Nishiyama, Yoshio

    2012-06-01

    We have performed an experiment of the scattering of the near field on a prism created by a laser wave, evanescent wave (EW), or plane wave (PW) of an incident angle slightly larger than or smaller than the critical angle, by a thin fiber of subwavelength diameter set above the prism, and we made an analytical theory of an adapted model for the experiment. We have been able to analyze the experimental data exactly by the model theory better than any other theory we have ever known. The importance of the multiple interaction of the wave between the fiber and the surface and also the close similarity of the scattering characteristics between the EW and the PW mentioned above have been acknowledged by the analysis of the data obtained.

  5. Strip specimen tests for pipeline materials and girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, William C. [Edison Welding Institute (EWI), Columbus, Ohio (United States)

    2009-07-01

    Strip specimen testing of pipeline materials has been widely applied as a method of getting data relevant to the performance of pipelines under axial direction loading. Comparisons of strip specimen against smaller standard tests (round tensile bar, fracture toughness specimens, polished round bars) and against full-scale or large-scale testing will be explored. Data from early-generation pipe welds from the 1920's to the 1940's to the most recent materials for offshore reeled pipe will be used for examples. Strip samples can provide full thickness information to take account of varying material properties or imperfection distribution through the thickness. Strip samples can also accommodate measurement of effects of the original surface finish or weld surface shape. Strip samples have more design flexibility than standard tests, but must be designed to limit stress concentrations and effects of local bending. (author)

  6. Fatigue of graphite/epoxy buffer strip panels with center cracks

    Science.gov (United States)

    Bigelow, C. A.

    1985-01-01

    The effects of fatigue loading on the behavior of graphite/epoxy panels with either S-Glass or Kevlar-49 buffer strips is studied. Buffer strip panels are fatigued and tested in tension to measure their residual strength with crack-like damage. Panels are made with 45/0/-45/90 sub 2s layup with either S-Glass or Kevlar-49 buffer strip material. The buffer strips are parallel to the loading direction and made by replacing narrow strips of the 0-degree graphite plies with strips of either 0-degree S-Glass/epoxy or Kevlar-49/epoxy on a one-for-one basis. The panels are subjected to a fatigue loading spectrum MINITWIST, the shortened version of the standardized load program for the wing lower surface of a transport aircraft. Two levels of maximum strain are used in the spectrum with three durations of the fatigue spectrum. One group of panels is preloaded prior to the application of the fatigue cycling. The preload consists of statistically loading the spectrum in tension until the crack-tip damage zone reaches the ajacent buffer strips. After fatigue loading, all specimens are statistically loaded in tension to failure to determine their residual strengths.

  7. Enrichment and stripping voltametric behavior of technetium traces at a carbon paste electrode modified with TTA

    International Nuclear Information System (INIS)

    Dick, R.; Ruf, H.; Ache, H.J.

    1988-06-01

    The possibility of enrichment as well as the stripping voltammetric behavior of technetium traces at a carbon paste electrode modified with thenoyltrifluoroacetone (TTA) was studied. Accumulation of Tc(IV) on the electrode surface occurs without application of a deposition voltage due to complex formation with TTA, probably resulting Tc(TTA) 4 . During the following cathodic potential scan made with the differential pulse mode a characteristic current peak is obtained at -40 mV (vs. Ag/AgCl) which increases with Tc concentration and deposition time. However, Tc(IV) gives much more sensitive stripping current signals if a reductive deposition potential of -0.4 V is applied, presumably on account of the formation of Tc(TTA) 3 . In this case an anodic voltammetric scan was applied resulting a stripping peak at about +30 mV, the height of which is related to the concentration of Tc in solution as well as to the time of deposition. Calibration graphs revealed good reproducibility for analytical application. The lower detection limit for Tc(IV) achieved for 1 M sodium chloride solutions 4.6 x 10 -9 M. Tc(VII) is not enriched in the absence of reduction which takes place only from about -0.6 V on with the pH optimally set at 3.5. Therefore it is basically possible to discriminate Tc(IV) from Tc(VII). (orig.) [de

  8. Photosensitive Strip RETHGEM

    CERN Document Server

    Peskov, Vladimir; Nappi, E.; Oliveira, R.; Paic, G.; Pietropaolo, F.; Picchi, P.

    2008-01-01

    An innovative photosensitive gaseous detector, consisting of a GEM like amplification structure with double layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our latest designs, the inner electrode consists of a metallic grid and the outer one is made of resistive strips; the latter are manufactured by a screen printing technology on the top of the metallic strips grid The inner metallic grid is used for 2D position measurements whereas the resistive layer provides an efficient spark protected operation at high gains - close to the breakdown limit. Detectors with active areas of 10cm x10cm and 10cm x20cm were tested under various conditions including the operation in photosensitive gas mixtures containing ethylferrocene or TMAE vapors. The new technique could have many applications requiring robust and reliable large area detectors for UV visualization, as for example, in Cherenkov imaging devices.

  9. Immunochromatographic strip assay for detection of bioactive Ganoderma triterpenoid, ganoderic acid A in Ganoderma lingzhi.

    Science.gov (United States)

    Sakamoto, Seiichi; Kikkawa, Nao; Kohno, Toshitaka; Shimizu, Kuniyoshi; Tanaka, Hiroyuki; Morimoto, Satoshi

    2016-10-01

    Ganoderic acid A (GAA) is one of the major Ganoderma triterpenes produced by medicinal mushroom belonging to the genus Ganoderma (Ganodermataceae). Due to its interesting pharmacological activities, Ganoderma species have been traditionally used in China for the treatment of various diseases. Herein, we developed a colloidal gold-based immunochromatographic strip assay (ICA) for the rapid detection of GAA using highly specific monoclonal antibody against GAA (MAb 12A) conjugated with gold nanoparticles. Using the developed ICA, the detection of GAA can be completed within 15min after dipping the test strip into an analyte solution with the limit of detection (LOD) for GAA of ~500ng/mL. In addition, this system makes it possible to perform a semi-quantitative analysis of GAA in Ganoderma lingzhi, where high reliability was evaluated by enzyme-linked immunosorbent assay (ELISA). The newly developed ICA can potentially be applied to the standardization of Ganoderma using GAA as an index because GAA is major triterpenoid present much in the mushroom. Copyright © 2016. Published by Elsevier B.V.

  10. Nanoscale Test Strips for Multiplexed Blood Analysis

    Science.gov (United States)

    Chan, Eugene

    2015-01-01

    A critical component of the DNA Medicine Institute's Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) sensor are nanoscale test strips, or nanostrips, that enable multiplexed blood analysis. Nanostrips are conceptually similar to the standard urinalysis test strip, but the strips are shrunk down a billionfold to the microscale. Each nanostrip can have several sensor pads that fluoresce in response to different targets in a sample. The strips carry identification tags that permit differentiation of a specific panel from hundreds of other nanostrip panels during a single measurement session. In Phase I of the project, the company fabricated, tested, and demonstrated functional parathyroid hormone and vitamin D nanostrips for bone metabolism, and thrombin aptamer and immunoglobulin G antibody nanostrips. In Phase II, numerous nanostrips were developed to address key space flight-based medical needs: assessment of bone metabolism, immune response, cardiac status, liver metabolism, and lipid profiles. This unique approach holds genuine promise for space-based portable biodiagnostics and for point-of-care (POC) health monitoring and diagnostics here on Earth.

  11. Data acquisition software for the CMS strip tracker

    International Nuclear Information System (INIS)

    Bainbridge, R; Cripps, N; Fulcher, J; Radicci, V; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Gill, K; Mirabito, L; Cole, J; Jesus, A C A; Giassi, A; Giordano, D; Gross, L; Hahn, K; Mersi, S; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS silicon strip tracker, providing a sensitive area of approximately 200 m 2 and comprising 10 million readout channels, has recently been completed at the tracker integration facility at CERN. The strip tracker community is currently working to develop and integrate the online and offline software frameworks, known as XDAQ and CMSSW respectively, for the purposes of data acquisition and detector commissioning and monitoring. Recent developments have seen the integration of many new services and tools within the online data acquisition system, such as event building, online distributed analysis, an online monitoring framework, and data storage management. We review the various software components that comprise the strip tracker data acquisition system, the software architectures used for stand-alone and global data-taking modes. Our experiences in commissioning and operating one of the largest ever silicon micro-strip tracking systems are also reviewed

  12. The development of drift-strip detectors based on CdZnTe

    DEFF Research Database (Denmark)

    Gostilo, V.; Budtz-Jørgensen, Carl; Kuvvetli, Irfan

    2002-01-01

    The design and technological development of a CdZnTe drift strip detector is described. The device is based on a monocrystal of dimensions 10 x 10 x 3 mm(3) and has a pitch of 200 mum and a strip width of 100 mum. The strip length is 9.5 mm. The distribution of the leakage currents of the strips...

  13. Eddy current distribution and lift force for finite MAGLEV strips

    Energy Technology Data Exchange (ETDEWEB)

    Atherton, D L; Eastham, A R; Fombrun, C; Chong, M

    1974-07-01

    The transverse distribution of induced eddy currents across a flat conducing strip of finite width, due to a rectangular dc magnet moving above it, was modelled experimentally, and was compared with that calculated for an infinite sheet. The electrodynamic suspension was simulated by means of a stationary ac-excited copper magnet suspended above an aluminum strip, and the induced surface current density was measured by a voltage pickup probe connected to a lock-in amplifier. The effect of reducing strip width is examined and shown to produce high current densities close to the edges. These results are related to the variation of lift force with strip width, determined by impedance modelling. A slight enhancement of lift is evident for intermediate strip widths.

  14. Analytic structure of the wave function for a hydrogen atom in an analytic potential

    International Nuclear Information System (INIS)

    Hill, R.N.

    1984-01-01

    The rate of convergence of an approximate method for solving Schroedinger's equation depends on the ability of the approximating sequence to mimic the analytic structure of the unknown exact wave function. Thus a knowledge of the analytic structure of the wave function can be of great value when approximation schemes are designed. Consider the Schroedinger equation [- 1/2 del 2 -r -1 +V(r)]Psi(r) = EPsi(r) for a hydrogen atom in a potential V(r). The general theory of elliptic partial differential equations implies that Psi is analytic at regular points, but no general theory is available at singular points. The present paper investigates the Coulomb singular point at r = 0 and shows that, if V(r) = V 1 (x, y, z)+rV 2 (x, y, z) where V 1 and V 2 are analytic functions of x, y, z at x = y = z = 0, then the wave function has the form Psi(r) = Psi 1 (x, y, z)+rPsi 2 (x, y, z) where Psi 1 and Psi 2 are analytic functions of x, y, z at x = y = z = 0

  15. Deuteron stripping reactions using dirac phenomenology

    Science.gov (United States)

    Hawk, E. A.; McNeil, J. A.

    2001-04-01

    In this work deuteron stripping reactions are studied using the distorted wave born approximation employing dirac phenomenological potentials. In 1982 Shepard and Rost performed zero-range dirac phenomenological stripping calculations and found a dramatic reduction in the predicted cross sections when compared with similar nonrelativistic calculations. We extend the earlier work by including full finite range effects as well as the deuteron's internal D-state. Results will be compared with traditional nonrelativistic approaches and experimental data at low energy.

  16. LYCORIS - A Large Area Strip Telescope

    CERN Document Server

    Krämer, U; Stanitzki, M; Wu, M

    2018-01-01

    The LYCORIS Large Area Silicon Strip Telescope for the DESY II Test Beam Facility is presented. The DESY II Test Beam Facility provides elec- tron and positron beams for beam tests of up to 6 GeV. A new telescope with a large 10 × 20 cm2 coverage area based on a 25 μm pitch strip sensor is to be installed within the PCMAG 1 T solenoid. The current state of the system is presented.

  17. Combined effect of bulk and surface damage on strip insulation properties of proton irradiated n$^{+}$-p silicon strip sensors

    CERN Document Server

    Dalal, R; Ranjan, K; Moll, M; Elliott-Peisert, A

    2014-01-01

    Silicon sensors in next generation hadron colliders willface a tremendously harsh radiation environment. Requirement tostudy rarest reaction channels with statistical constraints hasresulted in a huge increment in radiation flux, resulting in bothsurface damage and bulk damage. For sensors which are used in acharged hadron environment, both of these degrading processes takeplace simultaneously. Recently it has been observed in protonirradiated n$^{+}$-p Si strip sensors that n$^{+}$ strips had a goodinter-strip insulation with low values of p-spray and p-stop dopingdensities which is contrary to the expected behaviour from thecurrent understanding of radiation damage. In this work a simulationmodel has been devised incorporating radiation damage to understandand provide a possible explanation to the observed behaviour ofirradiated sensors.

  18. Analytical quadrics

    CERN Document Server

    Spain, Barry; Ulam, S; Stark, M

    1960-01-01

    Analytical Quadrics focuses on the analytical geometry of three dimensions. The book first discusses the theory of the plane, sphere, cone, cylinder, straight line, and central quadrics in their standard forms. The idea of the plane at infinity is introduced through the homogenous Cartesian coordinates and applied to the nature of the intersection of three planes and to the circular sections of quadrics. The text also focuses on paraboloid, including polar properties, center of a section, axes of plane section, and generators of hyperbolic paraboloid. The book also touches on homogenous coordi

  19. Condensation pressures in small pores: An analytical model based on density functional theory

    International Nuclear Information System (INIS)

    Nilson, R.H.; Griffiths, S.K.

    1999-01-01

    Integral methods are used to derive an analytical expression describing fluid condensation pressures in slit pores bounded by parallel plane walls. To obtain this result, the governing equations of density functional theory (DFT) are integrated across the pore width assuming that fluid densities within adsorbed layers are spatially uniform. The thickness, density, and free energy of these layers are expressed as composite functions constructed from asymptotic limits applicable to small and large pores. By equating the total free energy of the adsorbed layers to that of a liquid-full pore, we arrive at a closed-form expression for the condensation pressure in terms of the pore size, surface tension, and Lennard-Jones parameters of the adsorbent and adsorbate molecules. The resulting equation reduces to the Kelvin equation in the large-pore limit. It further reproduces the condensation pressures computed by means of the full DFT equations for all pore sizes in which phase transitions are abrupt. Finally, in the limit of extremely small pores, for which phase transitions may be smooth and continuous, this simple analytical expression provides a good approximation to the apparent condensation pressure indicated by the steepest portion of the adsorption isotherm computed via DFT. copyright 1999 American Institute of Physics

  20. An analytical theory of corona discharge plasmas

    International Nuclear Information System (INIS)

    Uhm, H.S.; Lee, W.M.

    1997-01-01

    In this paper we describe an analytical investigation of corona discharge systems. Electrical charge and the energy transfer mechanism are investigated based on the circuit analysis. Efficient delivery of electrical energy from the external circuit to the reactor chamber is a major issue in design studies. The optimum condition obtained in this paper ensures 100% energy transfer. Second-order coupled differential equations are numerically solved. All the analytical results agree remarkably well with numerical data. The reactor capacitor plays a pivotal role in circuit performance. The voltage profile is dominated by the reactor capacitor. Corona discharge properties in the reactor chamber are also investigated, assuming that a specified voltage profile V(t) is fed through the inner conductor. The analytical description is based on the electron moment equation. Defining the plasma breakdown parameter u=V/R c p, plasma is generated for a high-voltage pulse satisfying u>u c , where u c is the critical breakdown parameter defined by geometrical configuration. Here, u is in units of a million volts per m per atm, and R c is the outer conductor radius. It is found that the plasma density profile generated inside the reactor chamber depends very sensitively on the system parameters. A small change of a physical parameter can easily lead to a density change in one order of magnitude

  1. Induction heating in in-line strip production process

    International Nuclear Information System (INIS)

    Costa, P.; Santinelli, M.

    1995-05-01

    ISP (In-line Strip Production), a continuous process for steel strip production, has recently been set in an italian innovative plant, where ecological impact and power requirements are lighter than usual. This report describes the studies performed by ENEA (Italian Agency for New Technologies, Energy and the Environment), while a prototype reheating facility was arranged by Acciaieria ISP in Cremona (Italy). The authors, after a study of the prototype electromagnetic field, calculate the heating rate, with the thermal network method. Then they detect, with a 1-D-FEM, the heat diffusion through the strip cross section. Afterward, since the heat distribution depends on the eddy current density one, which is given by the magnetic field distribution, the authors, with a 3-D-FEM, carry out a coupled, electromagnetic and thermal, analysis in time domain. The strip temperature map is established by the balance between skin depth heating and surface cooling: a thermal analysis, performed with a moving 2-D-FEM, take into account the effects of the different heating and cooling situations, originated by the strip moving at a speed of 6m/min through four consecutive reheating facilities. The temperatures of a strip sample heated by the prototype have been monitored, acquired by a computer and related with the simulation results. The little difference between experiment and simulation assessed the qualitative and quantitative validity of this analysis, that has come out to be a tool, useful to evaluate the effects of possible improvements to the ISP process

  2. Analytic aspects of rational conformal field theories

    International Nuclear Information System (INIS)

    Kiritsis, E.B.; Lawrence Berkeley Lab., CA

    1990-01-01

    The problem of deriving linear differential equations for correlation functions of Rational Conformal Field Theories is considered. Techniques from the theory of fuchsian differential equations are used to show that knowledge of the central charge, dimensions of primary fields and fusion rules are enough to fix the differential equations for one- and two-point functions on the tours. Any other correlation function can be calculated along similar lines. The results settle the issue of 'exact solution' of rational conformal field theories. (orig.)

  3. Analysis of 'Coma strip' galaxy redshift catalog

    International Nuclear Information System (INIS)

    Klypin, A.A.; Karachentsev, I.D.; Lebedev, V.S.

    1990-01-01

    We present results of the analysis of a galaxy redshift catalog made at the 6-m telescope by Karachentsev and Kopylov (1990. Mon. Not. R. astr. Soc., 243, 390). The catalog covers a long narrow strip on the sky (10 arcmin by 63 0 ) and lists 283 galaxies up to limiting blue magnitude m B = 17.6. The strip goes through the core of Coma cluster and this is called the 'Coma strip' catalog. The catalog is almost two times deeper than the CfA redshift survey and creates the possibility of studying the galaxy distribution on scales of 100-250 Mpc. Due to the small number of galaxies in the catalog, we were able to estimate only very general and stable parameters of the distribution. (author)

  4. 31 CFR 356.31 - How does the STRIPS program work?

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false How does the STRIPS program work? 356.31 Section 356.31 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued...) Miscellaneous Provisions § 356.31 How does the STRIPS program work? (a) General. Notes or bonds may be “stripped...

  5. Using Comic Strips as a Book Report Alternative

    Science.gov (United States)

    Reading Teacher, 2012

    2012-01-01

    Comic strips are great to share with parents, younger students, and peers. This article presents an activity where students use a six-paneled comic strip to summarize a story. This activity allows for multiple interpretations and enhances comprehension by drawing attention to story elements.

  6. Technical performance of lactate biosensors and a test-strip device during labour.

    Science.gov (United States)

    Luttkus, A K; Fotopoulou, C; Sehouli, J; Stupin, J; Dudenhausen, J W

    2010-04-01

    Lactate in fetal blood has a high diagnostic power to detect fetal compromise due to hypoxia, as lactate allows an estimation of duration and intensity of metabolic acidemia. Biosensor technology allows an instantaneous diagnosis of fetal compromise in the delivery room. The goal of the current investigation is to define the preanalytical and analytical biases of this technology under routine conditions in a labour ward in comparison to test-strip technology, which allows measurement of lactate alone. Three lactate biosensors (RapidLab 865, Siemens Medical Solutions Diagnostics, Bad Nauheim, Germany; Radiometer ABL625 and ABL 700, Radiometer Copenhagen, Denmark) and one test-strip device (Lactate Pro, Oxford Instruments, UK) were evaluated regarding precision in serial and repetitive measurements in over 1350 samples of fetal whole blood. The coefficient of variation (CV) and the standard deviation (SD) were calculated. The average value of all three biosensors was defined as an artificial reference value (refval). Blood tonometry was performed in order to test the quality of respiratory parameters and to simulate conditions of fetal hypoxia (pO (2): 10 and 20 mmHg). The precision of serial measurements of all biosensors indicated a coefficient of variation (CV) between 1.55 and 3.16% with an SD from 0.042 to 0.053 mmol/L. The test-strip device (Lactate Pro) mounted to 0.117 mmol/L and 3.99% (SD, CV). When compared to our reference value (refval) ABL 625 showed the closest correlation of -0.1%, while Siemens RapidLab 865 showed an overestimation of +8.9%, ABL700 an underestimation of -6.2% and Lactate Pro of -3.7%. For routine use all tested biosensors show sufficient precision. The test-strip device shows a slightly higher standard deviation. A direct comparison of measured lactate values from the various devices needs to be interpreted with caution as each method detects different lactate concentrations. Furthermore, the 40 min process of tonometry led to an

  7. Analytical theory relating the depth of the sulfate-methane transition to gas hydrate distribution and saturation

    Science.gov (United States)

    Bhatnagar, Gaurav; Chatterjee, Sayantan; Chapman, Walter G.; Dugan, Brandon; Dickens, Gerald R.; Hirasaki, George J.

    2011-03-01

    We develop a theory that relates gas hydrate saturation in marine sediments to the depth of the sulfate-methane transition (SMT) zone below the seafloor using steady state, analytical expressions. These expressions are valid for systems in which all methane transported into the gas hydrate stability zone (GHSZ) comes from deeper external sources (i.e., advective systems). This advective constraint causes anaerobic oxidation of methane to be the only sulfate sink, allowing us to link SMT depth to net methane flux. We also develop analytical expressions that define the gas hydrate saturation profile based on SMT depth and site-specific parameters such as sedimentation rate, methane solubility, and porosity. We evaluate our analytical model at four drill sites along the Cascadia Margin where methane sources from depth dominate. With our model, we calculate average gas hydrate saturations across GHSZ and the top occurrence of gas hydrate at these sites as 0.4% and 120 mbsf (Site 889), 1.9% and 70 mbsf (Site U1325), 4.7% and 40 mbsf (Site U1326), and 0% (Site U1329), mbsf being meters below seafloor. These values compare favorably with average saturations and top occurrences computed from resistivity log and chloride data. The analytical expressions thus provide a fast and convenient method to calculate gas hydrate saturation and first-order occurrence at a given geologic setting where vertically upward advection dominates the methane flux.

  8. Magnetic ring for stripping enhancement

    International Nuclear Information System (INIS)

    Selph, F.

    1992-10-01

    A ring designed to recycle ions through a stripping medium offers the possibility for increasing output of the desired charge state by up to 4x. This could be a very important component of a Radioactive Nuclear Beam Facility. In order for such a ring to work effectively it must satisfy certain design conditions. These include achromaticity at the stripper, a dispersed region for an extraction magnet, and a number of first and higher order optics constraints which are necessary to insure that the beam emittance is not degraded unduly by the ring. An example is given of a candidate design of a stripping ring

  9. Analytic stochastic regularization and gauge theories

    International Nuclear Information System (INIS)

    Abdalla, E.; Gomes, M.; Lima-Santos, A.

    1987-04-01

    We prove that analytic stochatic regularization braks gauge invariance. This is done by an explicit one loop calculation of the two three and four point vertex functions of the gluon field in scalar chromodynamics, which turns out not to be geuge invariant. We analyse the counter term structure, Langevin equations and the construction of composite operators in the general framework of stochastic quantization. (author) [pt

  10. Do repeated rumble strip hits improve driver alertness?

    NARCIS (Netherlands)

    Watling, C.N.; Akerstedt, T.; Kecklund, L.G.; Anund, A.

    2016-01-01

    Driving while sleepy is associated with increased crash risk. Rumble strips are designed to alert a sleepy or inattentive driver when they deviate outside their driving lane. The current study sought to examine the effects of repeated rumble strip hits on levels of physiological and subjective

  11. Analytical Calculation of D- and Q-axis Inductance for Interior Permanent Magnet Motors Based on Winding Function Theory

    Directory of Open Access Journals (Sweden)

    Peixin Liang

    2016-07-01

    Full Text Available Interior permanent magnet (IPM motors are widely used in electric vehicles (EVs, benefiting from the excellent advantages of a more rational use of energy. For further improvement of energy utilization, this paper presents an analytical method of d- and q-axis inductance calculation for IPM motors with V-shaped rotor in no-load condition. A lumped parameter magnetic circuit model (LPMCM is adopted to investigate the saturation and nonlinearity of the bridge. Taking into account the influence of magnetic field distribution on inductance, the winding function theory (WFT is employed to accurately calculate the armature reaction airgap magnetic field and d- and q-axis inductances. The validity of the analytical technique is verified by the finite element method (FEM.

  12. Low-Cost Label-Free Biosensing Bimetallic Cellulose Strip with SILAR-Synthesized Silver Core-Gold Shell Nanoparticle Structures.

    Science.gov (United States)

    Kim, Wansun; Lee, Jae-Chul; Lee, Gi-Ja; Park, Hun-Kuk; Lee, Anbok; Choi, Samjin

    2017-06-20

    We introduce a label-free biosensing cellulose strip sensor with surface-enhanced Raman spectroscopy (SERS)-encoded bimetallic core@shell nanoparticles. Bimetallic nanoparticles consisting of a synthesis of core Ag nanoparticles (AgNP) and a synthesis of shell gold nanoparticles (AuNPs) were fabricated on a cellulose substrate by two-stage successive ionic layer absorption and reaction (SILAR) techniques. The bimetallic nanoparticle-enhanced localized surface plasmon resonance (LSPR) effects were theoretically verified by computational calculations with finite element models of optimized bimetallic nanoparticles interacting with an incident laser source. Well-dispersed raspberry-like bimetallic nanoparticles with highly polycrystalline structure were confirmed through X-ray and electron analyses despite ionic reaction synthesis. The stability against silver oxidation and high sensitivity with superior SERS enhancement factor (EF) of the low-cost SERS-encoded cellulose strip, which achieved 3.98 × 10 8 SERS-EF, 6.1%-RSD reproducibility, and <10%-degraded sustainability, implicated the possibility of practical applications in high analytical screening methods, such as single-molecule detection. The remarkable sensitivity and selectivity of this bimetallic biosensing strip in determining aquatic toxicities for prohibited drugs, such as aniline, sodium azide, and malachite green, as well as monitoring the breast cancer progression for urine, confirmed its potential as a low-cost label-free point-of-care test chip for the early diagnosis of human diseases.

  13. Evaluation of anatomy comic strips for further production and applications

    Science.gov (United States)

    Shin, Dong Sun; Kim, Dae Hyun; Park, Jin Seo; Jang, Hae Gwon

    2013-01-01

    The corresponding author of the study has been sketching comic strips to explain anatomy in a humorous manner. All the anatomy comic strips, including those in Korean (650 episodes) and English (451 episodes), can be viewed on the homepage (http://anatomy.co.kr). Such comic strips were created with the aim of assisting medical students. However, their impact was unknown, and therefore, we surveyed the students' responses. We noted that anatomy grades were better in the students who read the comic strips. The comics helped the trainees chat with individuals with and without a medical background. The authors also considered comments on the problems with the comic strips and attempted to find solutions. The episodes are being currently used and further produced for educational purposes. To support this effort, the readers' valuable opinions will be continuously collected and assessed. PMID:24179697

  14. Evaluation of anatomy comic strips for further production and applications.

    Science.gov (United States)

    Shin, Dong Sun; Kim, Dae Hyun; Park, Jin Seo; Jang, Hae Gwon; Chung, Min Suk

    2013-09-01

    The corresponding author of the study has been sketching comic strips to explain anatomy in a humorous manner. All the anatomy comic strips, including those in Korean (650 episodes) and English (451 episodes), can be viewed on the homepage (http://anatomy.co.kr). Such comic strips were created with the aim of assisting medical students. However, their impact was unknown, and therefore, we surveyed the students' responses. We noted that anatomy grades were better in the students who read the comic strips. The comics helped the trainees chat with individuals with and without a medical background. The authors also considered comments on the problems with the comic strips and attempted to find solutions. The episodes are being currently used and further produced for educational purposes. To support this effort, the readers' valuable opinions will be continuously collected and assessed.

  15. The charge collection in silicon strip detectors

    International Nuclear Information System (INIS)

    Boehringer, T.; Hubbeling, L.; Weilhammer, P.; Kemmer, J.; Koetz, U.; Riebesell, M.; Belau, E.; Klanner, R.; Lutz, G.; Neugebauer, E.; Seebrunner, H.J.; Wylie, A.

    1983-02-01

    The charge collection in silicon detectors has been studied, by measuring the response to high-energy particles of a 20μm pitch strip detector as a function of applied voltage and magnetic field. The results are well described by a simple model. The model is used to predict the spatial resolution of silicon strip detectors and to propose a detector with optimized spatial resolution. (orig.)

  16. Magnetic Fe3O4@TiO2 Nanoparticles-based Test Strip Immunosensing Device for Rapid Detection of Phosphorylated Butyrylcholinesterase

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Xiaoxiao; Zhang, Weiying; Lin, Yuehe; Du, Dan

    2013-12-15

    An integrated magnetic nanoparticles-based test-strip immunosensing device was developed for rapid and sensitive quantification of phosphorylated butyrylcholinesterase (BChE), the biomarker of exposure to organophosphous pesticides (OP), in human plasma. In order to overcome the difficulty in scarce availability of OP-specific antibody, here magnetic Fe3O4@TiO2 nanoparticles were used and adsorbed on the test strip through a small magnet inserted in the device to capture target OP-BChE through selective binding between TiO2 and OP moiety. Further recognition was completed by horseradish peroxidase (HRP) and anti-BChE antibody (Ab) co-immobilized gold nanoparticles (GNPs). Their strong affinities among Fe3O4@TiO2, OP-BChE and HRP/Ab-GNPs were characterized by quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and square wave voltammetry (SWV) measurements. After cutting off from test strip, the resulted immunocomplex (HRP/Ab-GNPs/OP-BChE/Fe3O4@TiO2) was measured by SWV using a screen printed electrode under the test zone. Greatly enhanced sensitivity was achieved by introduction of GNPs to link enzyme and antibody at high ratio, which amplifies electrocatalytic signal significantly. Moreover, the use of test strip for fast immunoreactions reduces analytical time remarkably. Coupling with a portable electrochemical detector, the integrated device with advanced nanotechnology displays great promise for sensitive, rapid and in-filed on-site evaluation of OP poisoning.

  17. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  18. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  19. Refuges, flower strips, biodiversity and agronomic interest.

    Science.gov (United States)

    Roy, Grégory; Wateau, Karine; Legrand, Mickaël; Oste, Sandrine

    2008-01-01

    Several arthropods are natural predators of pests, and they are able to reduce and control their population development. FREDON Nord Pas-de-Calais (Federation Regionate de Defense contre les Organismes Nuisibles = Regional Federation for Pest Control) has begun for a long time to form farmers to the recognition of beneficial arthropods and to show them their usefulness. These beneficial insects or arachnids are present everywhere, in orchards and even in fields which are areas relatively poor in biodiversity. Adults feed in the flower strips instead larvae and some adults feed on preys such as aphids or caterpillars. Most of the time, beneficial insects can regulate pest but sometimes, in agricultural area, they can't make it early enough and efficiently. Their action begin too late and there biodiversity and number are too low. It's possible to enhance their action by manipulating the ecological infrastructures, like sewing flower strips or installing refuges. Flower strips increase the density of natural enemies and make them be present earlier in the field in order to control pests. Refuges permit beneficial's to spend winter on the spot. So they're able to be active and to grow in number earlier. From 2004 to 2007, on the one hand, FREDON Nord Pas-de-Calais has developed a research program. Its purpose was to inventory practices and also tools and means available and to judge the advisability of using such or such beneficial refuge in orchards. On the second hand, it studied the impact in orchard of refuges on population of beneficial's and the difference there were between manufactured refuges and homemade refuges. Interesting prospects were obtained with some of them. Otherwise, since 2003, FREDON has studied flower strips influence on beneficial population and their impact on pest control. In cabbage fields, results of trials have shown that flower strips lead to a reduction of aphid number under acceptable economic level, up to 50 meters from flower strips

  20. Optimization of the process of steel strip perforation and nickel platting for the purpose of elimination of trichloroethylene from the cleaning process of perforated steel strip

    Directory of Open Access Journals (Sweden)

    Petrović Aleksandra B.

    2009-01-01

    Full Text Available In the production of pocket type electrodes for Ni-Cd batteries perforation of proper steel strips and then nickel platting of perforated steel strips were made. In the nickel platting process, the organic solvent, trichloroethylene, has previously been used for cleaning. Due to the carcinogenic nature of trichloroethylene and the many operations previously required during cleaning, it was considered to do cleaning of perforated steel strips without use of the mentioned organic solvent. In the purpose of elimination of trichloroethylene from the cleaning process of perforated steel strips, the tests of perforation of steel strips with use of oils of different viscosity were made. It was shown that there was no dysfunction during the work of the perforation plants, meaning there was no additional heating of the strips, deterring of the steel filings, nor excessive wearing of the perforation apparatus. The perforation percent was the same irrelevant of the viscosity of the used oil. Before being perforated using the oils with different viscosity, the nickel platting steel strips were cleaned in different degreasers (based on NaOH as well as on KOH. It was shown that efficient cleaning without the use of trichloroethylene is possible with the use of oil with smaller viscosity in the perforated steel strips process and the degreaser based on KOH in the cleaning process, before nickel platting. It also appeared that the alkali degreaser based on KOH was more efficient, bath corrections were made less often and the working period of the baths was longer, which all in summary means less quantity of chemicals needed for degreasing of perforated steel strips.

  1. Polymer Inclusion Membranes with Strip Dispersion

    Directory of Open Access Journals (Sweden)

    Yueh-Hsien Li

    2017-06-01

    Full Text Available The present work investigated the permeation of indium ions through a polymer inclusion membrane (PIM, prepared with cellulose triacetate (CTA as the base polymer, tris(2-butoxyethyl phosphate (TBEP as the plasticizer and di-(2-ethylhexylphosphoric acid (D2EHPA as the extractant. With 5 M HCl aqueous solution as the strip solution, we observed an initial indium permeability of 2.4 × 10−4 m/min. However, the permeability decreases with time, dropping to about 3.4 × 10−5 m/min after 200 min of operation. Evidence was obtained showing that hydrolysis of CTA occurred, causing a dramatic decrease in the feed pH (protons transported from strip to feed solutions and a loss of extractant and plasticizer from the membrane, and then leading to the loss of indium permeability. To alleviate the problem of hydrolysis, we proposed an operation scheme called polymer inclusion membranes with strip dispersion: dispersing the strip solution in extractant-containing oil and then bringing the dispersion to contact with the polymer membrane. Since the strong acid was dispersed in oil, the membrane did not directly contact the strong acid at all times, and membrane hydrolysis was thus alleviated and the loss of indium permeability was effectively prevented. With the proposed scheme, a stable indium permeability of 2.5 × 10−4 m/min was obtained during the whole time period of the permeation experiment.

  2. An integrated electrochemical device based on immunochromatographic test strip and enzyme labels for sensitive detection of disease-related biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Zhexiang; Wang, Jun; Wang, Hua; Li, Yao Q.; Lin, Yuehe

    2012-05-30

    A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. The sensor was further utilized to detect HBsAg in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population

  3. Determination of monoamine neurotransmitters in human urine by carrier-mediated liquid-phase microextraction based on solidification of stripping phase.

    Science.gov (United States)

    Jiang, Liwei; Chen, Yibang; Chen, Yejun; Ma, Ming; Tan, Yueming; Tang, Hao; Chen, Bo

    2015-11-01

    A novel method was developed for the analysis of monoamine neurotransmitters (MNTs) in human urine by carrier-mediated liquid-phase microextraction based on solidification of stripping phase method (CM-LPME-SSP) coupled with high performance liquid chromatography-electrochemical detector (HPLC-ECD). By adding an appropriate carrier in organic phase, simultaneous extraction of hydrophilic analytes, MNTs, with high enrichment factors (22.6-36.1 folds) and excellent sample cleanup was achieved. A new strategy, solidifying the aqueous stripping phase in the back-extraction process, was developed to facilitate the collection of the stripping phase as small as a few microliters. Combined with HPLC-ECD analysis, the linear ranges of the established method were 0.015-2.0 μg/mL for NE, E, DA, and 0.020-2.0 μg/mL for 5-HT. The limits of detection and quantification were in the range of 5.5-10.8 ng/mL and 15-20 ng/mL, respectively. The relative recoveries were in the range of 87-108%, with intraday and interday relative standard deviations lower than 13%. This method was successfully applied to analysis of MNTs in real urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Validity of HydraTrend reagent strips for the assessment of hydration status.

    Science.gov (United States)

    Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T

    2014-09-01

    Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.

  5. Significance of wave form parameters in stripping chronopotentiometric metal speciation analysis

    NARCIS (Netherlands)

    Town, R.M.; Leeuwen, van H.P.

    2002-01-01

    An analysis is presented of the significance of stripping chronopotentiometric (SCP) stripping peak parameters (peak potential, Ep, and peak half-width, w1/2) for determination of metal ion speciation. This study focuses on depletive SCP (low stripping current, I¿ constant), and considers the change

  6. Electrode/Dielectric Strip For High-Energy-Density Capacitor

    Science.gov (United States)

    Yen, Shiao-Ping S.

    1994-01-01

    Improved unitary electrode/dielectric strip serves as winding in high-energy-density capacitor in pulsed power supply. Offers combination of qualities essential for high energy density: high permittivity of dielectric layers, thinness, and high resistance to breakdown of dielectric at high electric fields. Capacitors with strip material not impregnated with liquid.

  7. Strip reduction testing of lubricants developed during ENFORM project

    DEFF Research Database (Denmark)

    Gazvoda, S.; Andreasen, Jan Lasson; Olsson, David Dam

    Strip reduction testing of lubricants developed during ENFORM project. Experiments were conducted with the strip reduction test [1] in order to classify experimental lubricants, developed during concerned project. One reference lubricant was used during testing....

  8. Micro-strip Metal Foil Detectors for the Beam Profile Monitoring

    CERN Document Server

    Pugatch, V M; Fedorovitch, O A; Mikhailenko, A V; Prystupa, S V; Pylypchenko, Y

    2005-01-01

    The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. Fast particles hitting a metal strip initiate Secondary Electron Emission (SEE) which occurs at 10 - 50 nm surface layers of a strip. The SEE yield is measured by a sensitive Charge Integrator with built-in current-to-frequency converter (1 Hz per 1 fA). The MMFD (deposited onto the 20 μm thick Si-wafer) with 32 Al strips (10 μm wide, 32 μm pitch) has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator for Single-Event-Upset studies of the BEETLE micro-chip. Similar MMFD (0.5 μm thick Ni-strips) with totally removed Si-wafer (by plasma-chemistry, at the working area of 8 x 10 mm2) has been applied for the on-line X-ray BPM at the HASYLAB (DESY). The number of photons (11.3 GeV, mean X-ray energy 18 keV) producing out of a strip a single SEE was evaluated as (1.5 ±0.5)* 104. MMFD has demonstrated stable...

  9. Removal of nitrogen from swine manure by ammonia stripping; Reduccion del contenido en nitrogeno amoniacal del purin procino mediante la tecnica de stripping

    Energy Technology Data Exchange (ETDEWEB)

    Hidalgo, M. D.; Alamo, J. del; Nunez, U.; Irusta, R. [Grupo de Tecnologia Ambiental . Laboratorio de Analisis y Estudios Medioambientales. Valladolid (Spain)

    2001-07-01

    Lab scale experiments were undertaken to investigate air stripping as method for removing ammonia from cattle effluents and, more concretely, from the liquid fraction of swine manure. The effects of packet size, influent pH, air to liquid flow ratio and liquid recirculation flow in the stripping tower were investigated. The high ammonia removal efficiency of the air stripping method indicates that it could provide an interim solution for current waste management problems in the swine industry. (Author) 5 refs.

  10. Flexible strip supercapacitors for future energy storage

    OpenAIRE

    Zhang, R-R; Xu, Y-M; Harrison, D; Fyson, J; Qiu, F-L; Southee, D

    2015-01-01

    Flexible strip supercapacitors are developed and their electrochemical properties are characterized. Activated carbon is used as the electrode material and it is found to have a good porous structure which provides a large surface area for energy storage. Furthermore, this activated carbon performs well. The manufacturing processes for the supercapacitors are described in detail and the preparation process has good reproducibility. The strip supercapacitors are combined in series and parallel...

  11. Analytical Model for the End-Bearing Capacity of Tapered Piles Using Cavity Expansion Theory

    Directory of Open Access Journals (Sweden)

    Suman Manandhar

    2012-01-01

    Full Text Available On the basis of evidence from model tests on increasing the end-bearing behavior of tapered piles at the load-settlement curve, this paper proposes an analytical spherical cavity expansion theory to evaluate the end-bearing capacity. The angle of tapering is inserted in the proposed model to evaluate the end-bearing capacity. The test results of the proposed model in different types of sands and different relative densities show good effects compared to conventional straight piles. The end-bearing capacity increases with increases in the tapering angle. The paper then propounds a model for prototypes and real-type pile tests which predicts and validates to evaluate the end-bearing capacity.

  12. Comparative characteristics of polystyrene scintillation strips

    International Nuclear Information System (INIS)

    Gapienko, V.A.; Denisov, A.G.; Mel'nikov, E.A.

    1992-01-01

    Results are provided for a study of the main characteristics of polystyrene scintillation strips with a cross-section of 200 x 10 mm with two different scintillation-additive compositions: 1.5% p-terphenyl + 0.01% POPOP and 1.5% p-terphenyl + 0.01% DBP. The mean light-attenuation lengths are 180 cm and 260 cm, respectively, for strips with POPOP and DBP. The emittances of the polystyrene scintillators with DBP and POPOP additives have a ratio of 0.8:1.0 as recorded by an FEU-110 photomultiplier. 2 refs., 1 fig., 2 tabs

  13. Commentary on "Distributed Revisiting: An Analytic for Retention of Coherent Science Learning"

    Science.gov (United States)

    Hewitt, Jim

    2015-01-01

    The article, "Distributed Revisiting: An Analytic for Retention of Coherent Science Learning" is an interesting study that operates at the intersection of learning theory and learning analytics. The authors observe that the relationship between learning theory and research in the learning analytics field is constrained by several…

  14. Theory of a spherical electrostatic probe in a continuum plasma: Analytical models

    International Nuclear Information System (INIS)

    Brailsford, A.D.

    1977-01-01

    A simple physical model of the charge distribution surrounding a biased spherical probe in a quiescent plasma, suggested by the theory of Su and Lam, is used to rederive the probe current-voltage characteristic. The result is compared with that of a slightly different version due to Kiel and with the exact numerical results of Baum and Chapkis. It is shown that if the ratio of the probe radius to the Debye length of the plasma is greater than or of the order of unity, the model calculation is in excellent agreement with the exact results when the dimensionless probe voltage phi/sup asterisk//sub p/,=vertical-barephi/sub p//kTvertical-bar in standard notation, is greater than 10, for both thick and thin sheaths. The comparison also provides an assessment of the importance of various additional validity criteria encountered in analytical treatments of the problem

  15. The Theory of Ratio Scale Estimation: Saaty's Analytic Hierarchy Process

    OpenAIRE

    Patrick T. Harker; Luis G. Vargas

    1987-01-01

    The Analytic Hierarchy Process developed by Saaty (Saaty, T. L. 1980. The Analytic Hierarchy Process. McGraw-Hill, New York.) has proven to be an extremely useful method for decision making and planning. However, some researchers in these areas have raised concerns over the theoretical basis underlying this process. This paper addresses currently debated issues concerning the theoretical foundations of the Analytic Hierarchy Process. We also illustrate through proof and through examples the v...

  16. Study the Z-Plane Strip Capacitance

    International Nuclear Information System (INIS)

    Parikh, H.; Swain, S.

    2005-01-01

    The BaBaR detector at the Stanford Linear Accelerator Center is currently undergoing an upgrade to improve its muon and neutral hadron detection system. The Resistive Plate Chambers (RPCs) that had been used till now have deteriorated in performance over the past few years and are being replaced by Limited Streamer Tube (LSTs). Each layer of the system consists of a set of up to 10 streamer tube modules which provide one coordinate (φ coordinate) and a single ''Z-plane'' which provides the Z coordinate of the hit. The large area Z-planes (up to 12m 2 ) are 1mm thick and contain 96 copper strips that detect the induced charge from avalanches created in the streamer tube wires. All the Z-planes needed for the upgrade have already been constructed, but only a third of the planes were installed last summer. After installing the 24 Z-planes last year, it was learned that 0.7% of the strips were dead when put inside the detector. This was mainly due to the delicate solder joint between the read-out cable and the strip, and since it is difficult to access or replace the Z-planes inside the detector, it is very important to perform various tests to make sure that the Z-planes will be efficient and effective in the long term. We measure the capacitance between the copper strips and the ground plane, and compare it to the theoretical value that we expect. Instead of measuring the capacitance channel by channel, which would be a very tedious job, we developed a more effective method of measuring the capacitance. Since all the Z-planes were built at SLAC, we also built a smaller 46 cm by 30 cm Z-plane with 12 strips just to see how they were constructed and to gain a better understanding about the solder joints

  17. Low-resistance strip sensors for beam-loss event protection

    International Nuclear Information System (INIS)

    Ullán, M.; Benítez, V.; Quirion, D.; Zabala, M.; Pellegrini, G.; Lozano, M.; Lacasta, C.; Soldevila, U.; García, C.; Fadeyev, V.; Wortman, J.; DeFilippis, J.; Shumko, M.; Grillo, A.A; Sadrozinski, H.F.-W.

    2014-01-01

    AC-coupled silicon strip sensors can be damaged in case of a beam loss due to the possibility of a large charge accumulation in the bulk, developing very high voltages across the coupling capacitors which can destroy them. Punch-through structures are currently used to avoid this problem helping to evacuate the accumulated charge as large voltages are developing. Nevertheless, previous experiments, performed with laser pulses, have shown that these structures can become ineffective in relatively long strips. The large value of the implant resistance can effectively isolate the “far” end of the strip from the punch-through structure leading to large voltages. We present here our developments to fabricate low-resistance strip sensors to avoid this problem. The deposition of a conducting material in contact with the implants drastically reduces the strip resistance, assuring the effectiveness of the punch-through structures. First devices have been fabricated with this new technology. Initial results with laser tests show the expected reduction in peak voltages on the low resistivity implants. Other aspects of the sensor performance, including the signal formation, are not affected by the new technology

  18. Silicon strip detector qualification for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kaussen, Gordon

    2008-10-06

    To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The performance of the participating two shells of the TIB, four rods of the TOB and two petals of the TEC (representing about 1% of the final strip tracker) could be studied in different magnetic fields over a period of approximately two month using cosmic muon signals. The last test before inserting the tracker in the CMS experiment was the Tracker Slice Test performed in spring/summer 2007 at the Tracker Integration Facility (TIF) at CERN after installing all subdetectors in the tracker support tube. Approximately 25% of the strip tracker +z side was powered and read out using a cosmic ray trigger built up of scintillation counters. In total, about 5 million muon events were recorded under various operating conditions. These events together with results from commissioning runs were used to study the detector response like cluster charges, signal-to-noise ratios and single strip noise behaviour as well as to identify faulty channels which turned out to be in the order of a few per mille. The performance of the silicon strip tracker during these different construction stages is discussed in this thesis with a special emphasis on the tracker end caps. (orig.)

  19. Silicon strip detector qualification for the CMS experiment

    International Nuclear Information System (INIS)

    Kaussen, Gordon

    2008-01-01

    To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The performance of the participating two shells of the TIB, four rods of the TOB and two petals of the TEC (representing about 1% of the final strip tracker) could be studied in different magnetic fields over a period of approximately two month using cosmic muon signals. The last test before inserting the tracker in the CMS experiment was the Tracker Slice Test performed in spring/summer 2007 at the Tracker Integration Facility (TIF) at CERN after installing all subdetectors in the tracker support tube. Approximately 25% of the strip tracker +z side was powered and read out using a cosmic ray trigger built up of scintillation counters. In total, about 5 million muon events were recorded under various operating conditions. These events together with results from commissioning runs were used to study the detector response like cluster charges, signal-to-noise ratios and single strip noise behaviour as well as to identify faulty channels which turned out to be in the order of a few per mille. The performance of the silicon strip tracker during these different construction stages is discussed in this thesis with a special emphasis on the tracker end caps. (orig.)

  20. Analytical solution to the hybrid diffusion-transport equation

    International Nuclear Information System (INIS)

    Nanneh, M.M.; Williams, M.M.R.

    1986-01-01

    A special integral equation was derived in previous work using a hybrid diffusion-transport theory method for calculating the flux distribution in slab lattices. In this paper an analytical solution of this equation has been carried out on a finite reactor lattice. The analytical results of disadvantage factors are shown to be accurate in comparison with the numerical results and accurate transport theory calculations. (author)

  1. Metal films with imprinted nanostructures by template stripping

    DEFF Research Database (Denmark)

    Eriksen, René Lynge; Pors, Anders; Dreier, Jes

    We present a novel template stripping procedure for fabricating metal films with imprinted nanostructures. The basic idea is to deposit a gold film onto a nano-structured substrate and subsequently strip the film from the substrate surface thereby revealing imprinted nanostructures in the film...... result is a thin gold film with imprinted nano-cavities....

  2. Condensation pressures in small pores: An analytical model based on density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    R. H. Nilson; S. K. Griffiths

    1999-02-01

    Adsorption and condensation are critical to many applications of porous materials including filtration, separation, and the storage of gases. Integral methods are used to derive an analytical expression describing fluid condensation pressures in slit pores bounded by parallel plane walls. To obtain this result, the governing equations of Density Functional Theory (DFT) are integrated across the pore width assuming that fluid densities within adsorbed layers are spatially uniform. The thickness, density, and energy of these layers are expressed as composite functions constructed from asymptotic limits applicable to small and large pores. By equating the total energy of the adsorbed layers to that of a liquid-full pore, the authors arrive at a closed-form expression for the condensation pressure in terms of the pore size, surface tension, and Lennard-Jones parameters of the adsorbent and adsorbate molecules. The resulting equation reduces to the Kelvin equation in the large-pore limit. It further reproduces the condensation pressures computed by means of the full DFT equations for all pore sizes in which phase transitions are abrupt. Finally, in the limit of extremely small pores, for which phase transitions may be smooth and continuous, this simple analytical expression provides a good approximation to the apparent condensation pressure indicated by the steepest portion of the adsorption isotherm computed via DFT.

  3. Liquidity, Reconstitution, and the Value of U.S. Treasury Strips.

    OpenAIRE

    Daves, Phillip R; Ehrhardt, Michael C

    1993-01-01

    An apparent pricing anomaly exists in the market for U.S. Treasury strips: zero-coupon strips created from principal payments typically trade at significantly higher prices than otherwi se identical zero-coupon strips created from coupon payments. In additi on to documenting this phenomenon, this study demonstrates that differences in liquidity and differences in reconstitution characteristics explain much of this price variation. Copyright 1993 by American Finance Association.

  4. Deuteron stripping reactions with Tabakin potential

    International Nuclear Information System (INIS)

    Osman, A.

    1976-05-01

    Deuteron stripping reactions are considered. Due to the strong repulsion between nucleons at very short distances, we have investigated the nuclear short-range correlations. The neutron proton nuclear potential in the deuteron is taken as a short-range repulsive core surrounded by a long-range attractive potential. The neutron-proton potential is taken as the Tabakin separable potential to take into account the short-range correlations. The differential cross-sections for deuteron stripping reactions have been calculated in two different cases by taking Yamaguchi or Breit et al type parameters for the Tabakin potential used. The angular distributions for different (d,p) stripping reactions on the different target nuclei 28 Si, 32 , 34 S, 36 Ar, 40 , 48 Ca, 50 , 52 , 54 Cr have been calculated using the DWBA calculations. Our present theoretical calculations for the angular distributions of the different reactions cosidered have been fitted to the experimental data, where good agreement is obtained. The extracted spectroscopic factors from the present work are found to be more reliable

  5. Numerical Simulation of a Novel Sensing Approach Based on Abnormal Blocking by Periodic Grating Strips near the Silicon Wire Waveguide

    Directory of Open Access Journals (Sweden)

    Andrei Tsarev

    2018-05-01

    Full Text Available This paper discusses the physical nature and the numerical modeling of a novel approach of periodic structures for applications as photonic sensors. The sensing is based on the high sensitivity to the cover index change of the notch wavelength. This sensitivity is due to the effect of abnormal blocking of the guided wave propagating along the silicon wire with periodic strips overhead it through the silica buffer. The structure sensing is numerically modeled by 2D and 3D finite difference time domain (FDTD method, taking into account the waveguide dispersion. The modeling of the long structures (more than 1000 strips is accomplished by the 2D method of lines (MoL with a maximal implementation of the analytical feature of the method. It is proved that the effect of abnormal blocking could be used for the construction of novel types of optical sensors.

  6. Precipitation stripping of neodymium from carboxylate extractant with aqueous oxalic acid solutions

    International Nuclear Information System (INIS)

    Konishi, Yasuhiro; Asai, Satoru; Murai, Tetuya

    1993-01-01

    This paper describes a precipitation stripping method in which neodymium ions are stripped from carboxylate extractant in organic solvent and simultaneously precipitated with aqueous oxalic acid solution. For the single-stage process, a quantitative criterion for precipitating oxalate powders was derived theoretically, and stripping experiments were done under the precipitation conditions. The resultant precipitates were neodymium oxalate, which is completely free from contamination by the carboxylate extractant and the organic solvent. The overall rate of stripping was controlled by the transfer of neodymium carboxylate in the organic solution, indicating that the presence of oxalic acid in the aqueous phase has no effect on the stripping rate. These findings demonstrate the feasibility of combining the conventional stripping and precipitation stages in a solvent extraction process for separation and purification of rare earths

  7. Analytical mechanics for relativity and quantum mechanics

    CERN Document Server

    Johns, Oliver Davis

    2011-01-01

    Analytical Mechanics for Relativity and Quantum Mechanics is an innovative and mathematically sound treatment of the foundations of analytical mechanics and the relation of classical mechanics to relativity and quantum theory. It is intended for use at the introductory graduate level. A distinguishing feature of the book is its integration of special relativity into teaching of classical mechanics. After a thorough review of the traditional theory, Part II of the book introduces extended Lagrangian and Hamiltonian methods that treat time as a transformable coordinate rather than the fixed parameter of Newtonian physics. Advanced topics such as covariant Langrangians and Hamiltonians, canonical transformations, and Hamilton-Jacobi methods are simplified by the use of this extended theory. And the definition of canonical transformation no longer excludes the Lorenz transformation of special relativity. This is also a book for those who study analytical mechanics to prepare for a critical exploration of quantum...

  8. Methods and applications of analytical perturbation theory

    International Nuclear Information System (INIS)

    Kirchgraber, U.; Stiefel, E.

    1978-01-01

    This monograph on perturbation theory is based on various courses and lectures held by the authors at the ETH, Zurich and at the University of Texas, Austin. Its principal intention is to inform application-minded mathematicians, physicists and engineers about recent developments in this field. The reader is not assumed to have mathematical knowledge beyond what is presented in standard courses on analysis and linear algebra. Chapter I treats the transformations of systems of differential equations and the integration of perturbed systems in a formal way. These tools are applied in Chapter II to celestial mechanics and to the theory of tops and gyroscopic motion. Chapter III is devoted to the discussion of Hamiltonian systems of differential equations and exposes the algebraic aspects of perturbation theory showing also the necessary modifications of the theory in case of singularities. The last chapter gives the mathematical justification for the methods developed in the previous chapters and investigates important questions such as error estimations for the solutions and asymptotic stability. Each chapter ends with useful comments and an extensive reference to the original literature. (HJ) [de

  9. Impurities that cause difficulty in stripping actinides from commercial tetraalkylcarbamoylmethylphosphonates

    International Nuclear Information System (INIS)

    Bahner, C.T.; Shoun, R.R.; McDowell, W.J.

    1977-09-01

    Dihexyl[(diethylcarbamoyl)methyl]phosphonate (DHDECMP) in diethylbenzene extracts actinides well from 6 M nitric acid solution, but commercially available DHDECMP contains impurities which interfere with stripping the actinides from the organic extract. DHDECMP purified by molecular distillation does not contain these impurities, but the pot residue contains increased concentrations of them. Heating the purified DHDECMP causes the formation of products which interfere with stripping in the same way, suggesting that high temperatures employed in the manufacture of DHDECMP may produce the offending impurities. These impurities can be separated from the heat-decomposed material or the pot residues by dilution with a large volume of hexanes (causing part of the impurities to separate as a second liquid phase) followed by equilibration of the hexane solution with dilute alkali. After the treatment with hexane and dilute alkali, the DHDECMP is readily recovered and functions well in the actinide extraction process. Dibutyl[(dibutylcarbamoyl)methyl]-phosphonate (DBDBCMP) and di(2-ethylhexyl)[(diethylcarbamoyl)-methyl]phosphonate (DEHDECMP) are purified less effectively by these methods. Similar separation methods using diethylbenzene or CCl 4 as solvent do not remove impurities as completely as the hexane process. Impurities can also be removed from a benzene solution of the DHDECMP pot residue by passing it through a column packed with silica gel or diethylaminoethyl cellulose. These impurities have been separated into fractions for analytical examination by use of various solvents and by column chromatography. Hexyl hydrogen [(diethylcarbamoyl)methyl]-phosphonate has been identified tentatively as a principal objectionable impurity. Dihexyl phosphoric acid and possibly dihexylphosphonate have been identified in other fractions

  10. An analytical and experimental study of pool boiling with particular reference to additives

    International Nuclear Information System (INIS)

    Owens, W.L. Jr.

    1963-05-01

    An experimental investigation of nucleate boiling heat transfer and critical heat flux is presented for water and various aqueous solutions boiling from horizontal stainless steel tubes and flat strips at atmospheric pressure. An integral method solution for film boiling is given and compared with existing experimental data. Analytical solutions are also obtained for the temperature profiles with periodic internal heating of a flat plate and a cylinder. (author)

  11. Pion form factor in QCD sum rules, local duality approach, and O(A2) fractional analytic perturbation theory

    International Nuclear Information System (INIS)

    Bakulev, Alexander P.

    2010-01-01

    Using the results on the electromagnetic pion Form Factor (FF) obtained in the O(α s ) QCD sum rules with non-local condensates [A.P. Bakulev, A.V. Pimikov, and N.G. Stefanis, Phys. Rev. D79 (2009) 093010] we determine the effective continuum threshold for the local duality approach. Then we apply it to construct the O(α s 2 ) estimation of the pion FF in the framework of the fractional analytic perturbation theory.

  12. Contemporary Privacy Theory Contributions to Learning Analytics

    Science.gov (United States)

    Heath, Jennifer

    2014-01-01

    With the continued adoption of learning analytics in higher education institutions, vast volumes of data are generated and "big data" related issues, including privacy, emerge. Privacy is an ill-defined concept and subject to various interpretations and perspectives, including those of philosophers, lawyers, and information systems…

  13. Reforestation of strip-mined lands in West Virginia

    Science.gov (United States)

    H. Spencer Potter; Sidney Weitzman; George R., Jr. Trimble

    1951-01-01

    The early 1940's witnessed a striking increase in strip-mining throughout the eastern coal region. West Virginia, with its extensive coal resources, naturally was caught in the full current of this shift in mining methods. Today the raw gash on the hillside - almost infallibly the mark of a strip-mine operation - is a familiar sight in the State.

  14. Stripping foils for the PSB H- injection system

    CERN Document Server

    Aiba, M; Goddard, B; Weterings, W

    2009-01-01

    Beam physics considerations for the stripping foil of the PSB H- injection system are described, including the arguments for the foil type, thickness, geometry and positioning. The foil performance considerations are described, including expected stripping efficiency, emittance growth, energy straggling, temperature and lifetime. The required movement ranges and tolerances are detailed, together with the assumptions used.

  15. Quality Tests of Double-Sided Silicon Strip Detectors

    CERN Document Server

    Cambon, T; CERN. Geneva; Fintz, P; Guillaume, G; Jundt, F; Kuhn, C; Lutz, Jean Robert; Pagès, P; Pozdniakov, S; Rami, F; Sparavec, K; Dulinski, W; Arnold, L

    1997-01-01

    The quality of the SiO2 insulator (AC coupling between metal and implanted strips) of double-sided Silicon strip detectors has been studied by using a probe station. Some tests performed on 23 wafers are described and the results are discussed. Remark This note seems to cause problems with ghostview but it can be printed without any problem.

  16. Evaluation of a portable urinary pH meter and reagent strips.

    Science.gov (United States)

    De Coninck, Vincent; Keller, Etienne Xavier; Rodríguez-Monsalve, María; Haymann, Jean-Philippe; Doizi, Steeve; Traxer, Olivier

    2018-04-27

    To evaluate a portable electronic pH meter and to put its accuracy in perspective with reagent strips read by a layperson, a healthcare professional and an electronic reading device. Based on a pre-analysis on 20 patients, a sample size of 77 urine aliquots from healthy volunteers was necessary to obtain sufficient study power. Measurements of urinary pH were obtained by use of reagent strips, a portable pH meter and a laboratory pH meter (gold standard). Reagents strips were read by a professional experienced in interpreting strips, a layperson, and an electronic strip reader. The mean matched pair difference between measurement methods was analyzed by the paired t-test. The degree of correlation and agreement were evaluated by the Pearson's correlation coefficient and Bland-Altman plots, respectively. The mean matched pair difference between the gold standard and all other pH measurement methods was the smallest with the portable electronic pH meter (bias 0.01, 95% CI -0.07 to 0.08; p=0.89), followed by strips read by a professional (bias -0.09, 95% CI -0.21 to 0.02; p=0.10), layperson (bias -0.17, 95% CI -0.31 to -0.04; p=0.015) and electronic strip reader (bias -0.29, 95% CI -0.41 to -0.16; pmeter achieved the highest Pearson's correlation coefficient and narrowest 95% limits of agreement, followed by strip interpretation by a professional, the electronic strip reader and the layperson. In order to quantify the ability of pH measurement methods to correctly classify values within a predefined urinary pH target range, we performed classification tests for several stones. The portable electronic pH meter outperformed all other measurement methods for negative predictive values. Findings of the current study support that the portable electronic pH meter is a reliable pH measuring device. It seems to be more accurate compared to reagent strips readings.

  17. A new strips tracker for the upgraded ATLAS ITk detector

    Science.gov (United States)

    David, C.

    2018-01-01

    The ATLAS detector has been designed and developed to function in the environment of the present Large Hadron Collider (LHC). At the next-generation tracking detector proposed for the High Luminosity LHC (HL-LHC), the so-called ATLAS Phase-II Upgrade, the fluences and radiation levels will be higher by as much as a factor of ten. The new sub-detectors must thus be faster, of larger area, more segmented and more radiation hard while the amount of inactive material should be minimized and the power supply to the front-end systems should be increased. For those reasons, the current inner tracker of the ATLAS detector will be fully replaced by an all-silicon tracking system that consists of a pixel detector at small radius close to the beam line and a large area strip tracker surrounding it. This document gives an overview of the design of the strip inner tracker (Strip ITk) and summarises the intensive R&D activities performed over the last years by the numerous institutes within the Strips ITk collaboration. These studies are accompanied with a strong prototyping effort to contribute to the optimisation of the Strip ITk's structure and components. This effort culminated recently in the release of the ATLAS Strips ITk Technical Design Report (TDR).

  18. Predictive Analytics in Information Systems Research

    OpenAIRE

    Shmueli, Galit; Koppius, Otto

    2011-01-01

    textabstractThis research essay highlights the need to integrate predictive analytics into information systems research and shows several concrete ways in which this goal can be accomplished. Predictive analytics include empirical methods (statistical and other) that generate data predictions as well as methods for assessing predictive power. Predictive analytics not only assist in creating practically useful models, they also play an important role alongside explanatory modeling in theory bu...

  19. Comparison of blood glucose test strips in the detection of neonatal hypoglycaemia

    OpenAIRE

    Wilkins, B H; Kalra, D

    1982-01-01

    Blood glucose levels were estimated in 101 neonatal blood samples using three glucose test strip methods and the results compared with those from a laboratory. BM-test-glycemie 20-800 test strips and Reflotest-hypoglycemie test strips gave a rapid and reliable estimate of blood glucose level in the range 0-8 mmol/l (0-140 mg/100 ml). Dextrostix test strips tended to overestimate all blood glucose levels.

  20. Cancel and rethink in the Wason selection task: further evidence for the heuristic-analytic dual process theory.

    Science.gov (United States)

    Wada, Kazushige; Nittono, Hiroshi

    2004-06-01

    The reasoning process in the Wason selection task was examined by measuring card inspection times in the letter-number and drinking-age problems. 24 students were asked to solve the problems presented on a computer screen. Only the card touched with a mouse pointer was visible, and the total exposure time of each card was measured. Participants were allowed to cancel their previous selections at any time. Although rethinking was encouraged, the cards once selected were rarely cancelled (10% of the total selections). Moreover, most of the cancelled cards were reselected (89% of the total cancellations). Consistent with previous findings, inspection times were longer for selected cards than for nonselected cards. These results suggest that card selections are determined largely by initial heuristic processes and rarely reversed by subsequent analytic processes. The present study gives further support for the heuristic-analytic dual process theory.

  1. Brief Report: Assessment of the Social-Emotional Profile in Children with Autism Spectrum Disorders Using a Novel Comic Strip Task

    Science.gov (United States)

    Sivaratnam, Carmel S.; Cornish, Kim; Gray, Kylie M.; Howlin, Patricia; Rinehart, Nicole J.

    2012-01-01

    This study investigated whether the novel Comic Strip Task (CST) could be used to detect Theory-of-Mind impairments (ToM) in 4- to 8-year-old children with high functioning Autism Spectrum Disorders (ASD). Twelve children with either high-functioning autism or Asperger's Disorder and 12 typically-developing children completed the 21-item measure.…

  2. Buffers and vegetative filter strips

    Science.gov (United States)

    Matthew J. Helmers; Thomas M. Isenhart; Michael G. Dosskey; Seth M. Dabney

    2008-01-01

    This chapter describes the use of buffers and vegetative filter strips relative to water quality. In particular, we primarily discuss the herbaceous components of the following NRCS Conservation Practice Standards.

  3. The depletion properties of silicon microstrip detectors with variable strip pitch

    International Nuclear Information System (INIS)

    Krizmanic, J.F.

    1994-01-01

    We have investigated the depletion properties of trapezoidal shaped silicon microstrip detectors which have variable strip pitch. Four types of detectors were examined: three detectors have constant strip width and a fourth has a varying strip width. The detectors are single sided with readout performed via p + strips. The depletion properties of the devices were measured using two different methods. The first used capacitance versus voltage measurements, while the second used a 1060 nm wavelength laser coupled to a single mode fiber with a mode field diameter less than 10 μm. The small laser spot size allowed for the depletion depth to be measured in a localized area of the detector. The laser induced charge on an electrode was measured as a function of reverse bias voltage using a sensitive charge preamplifier. The depletion voltages of the detectors demonstrate a strong dependence upon the ratio of strip width to strip pitch. Moreover, these measurements show that a large value of this ratio yields a lower depletion voltage and vice versa. (orig.)

  4. A GEM readout with radial zigzag strips and linear charge-sharing response

    Science.gov (United States)

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak; Purschke, Martin L.; Woody, Craig

    2018-04-01

    We study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures are implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Angular resolutions of 60-84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.

  5. Algebraic and analytic methods in representation theory

    CERN Document Server

    Schlichtkrull, Henrik

    1996-01-01

    This book is a compilation of several works from well-recognized figures in the field of Representation Theory. The presentation of the topic is unique in offering several different points of view, which should makethe book very useful to students and experts alike.Presents several different points of view on key topics in representation theory, from internationally known experts in the field

  6. The path dependency theory: analytical framework to study institutional integration. The case of France.

    Science.gov (United States)

    Trouvé, Hélène; Couturier, Yves; Etheridge, Francis; Saint-Jean, Olivier; Somme, Dominique

    2010-06-30

    The literature on integration indicates the need for an enhanced theorization of institutional integration. This article proposes path dependence as an analytical framework to study the systems in which integration takes place. PRISMA proposes a model for integrating health and social care services for older adults. This model was initially tested in Quebec. The PRISMA France study gave us an opportunity to analyze institutional integration in France. A qualitative approach was used. Analyses were based on semi-structured interviews with actors of all levels of decision-making, observations of advisory board meetings, and administrative documents. Our analyses revealed the complexity and fragmentation of institutional integration. The path dependency theory, which analyzes the change capacity of institutions by taking into account their historic structures, allows analysis of this situation. The path dependency to the Bismarckian system and the incomplete reforms of gerontological policies generate the coexistence and juxtaposition of institutional systems. In such a context, no institution has sufficient ability to determine gerontology policy and build institutional integration by itself. Using path dependence as an analytical framework helps to understand the reasons why institutional integration is critical to organizational and clinical integration, and the complex construction of institutional integration in France.

  7. Sediment removal by prairie filter strips in row-cropped ephemeral watersheds

    Science.gov (United States)

    Matthew J. Helmers; Xiaobo Zhou; Heidi Asbjornsen; Randy Kolka; Mark D. Tomer; Richard M. Cruse

    2012-01-01

    Twelve small watersheds in central Iowa were used to evaluate the eff ectiveness of prairie filter strips (PFS) in trapping sediment from agricultural runoff. Four treatments with PFS of different size and location (100% rowcrop, 10% PFS of total watershed area at footslope, 10% PFS at footslope and in contour strips, 20% PFS at footslope and in contour strips)...

  8. Application of Semi-analytical Satellite Theory orbit propagator to orbit determination for space object catalog maintenance

    Science.gov (United States)

    Setty, Srinivas J.; Cefola, Paul J.; Montenbruck, Oliver; Fiedler, Hauke

    2016-05-01

    Catalog maintenance for Space Situational Awareness (SSA) demands an accurate and computationally lean orbit propagation and orbit determination technique to cope with the ever increasing number of observed space objects. As an alternative to established numerical and analytical methods, we investigate the accuracy and computational load of the Draper Semi-analytical Satellite Theory (DSST). The standalone version of the DSST was enhanced with additional perturbation models to improve its recovery of short periodic motion. The accuracy of DSST is, for the first time, compared to a numerical propagator with fidelity force models for a comprehensive grid of low, medium, and high altitude orbits with varying eccentricity and different inclinations. Furthermore, the run-time of both propagators is compared as a function of propagation arc, output step size and gravity field order to assess its performance for a full range of relevant use cases. For use in orbit determination, a robust performance of DSST is demonstrated even in the case of sparse observations, which is most sensitive to mismodeled short periodic perturbations. Overall, DSST is shown to exhibit adequate accuracy at favorable computational speed for the full set of orbits that need to be considered in space surveillance. Along with the inherent benefits of a semi-analytical orbit representation, DSST provides an attractive alternative to the more common numerical orbit propagation techniques.

  9. Analytic perturbation theory in analyzing some QCD observables

    International Nuclear Information System (INIS)

    Shirkov, D.V.

    2001-01-01

    The paper is devoted to application of recently devised ghost-free Analytic Perturbation Theory (APT) for analysis of some QCD observables. We start with the discussion of the main problem of the perturbative QCD - ghost singularities and with the resume of this trouble solution within the APT. By a few examples in the various energy and momentum transfer regions (with the flavor number f = 3, 4 and 5) we demonstrate the effect of improved convergence of the APT modified perturbative QCD expansion. Our first observation is that in the APT analysis the three-loop contribution (of an order of α s 3 ) is as a rule numerically inessential. This raises hope for practical solving the well-known problem of asymptotic nature of common QFT perturbation series. The second conclusion is that a common perturbative analysis of time-like events with the big π 2 term in the π 2 coefficient is not adequate at s ≤ 2 GeV 2 . In particular, this relates to τ decay. Then, for the 'high' (f = 5) region it is shown that the common two-loop (NLO, NLLA) perturbation approximation widely used there (at 10 GeV ≤ √s ≤ 170 GeV) for analysis of shape/events data contains a systematic negative error of a 1 - 2 per cent level for the extracted α bar s (2) values. Our physical conclusion is that the α bar s (M Z 2 ) value averaged over the f = 5 data s (M Z 2 )> APT; f= 5 ≅ 0.124 appreciably differs from the currently accepted 'world average' (= 0.118)

  10. An analytic thomism?

    Directory of Open Access Journals (Sweden)

    Daniel Alejandro Pérez Chamorro.

    2012-12-01

    Full Text Available For 50 years the philosophers of the Anglo-Saxon analytic tradition (E. Anscombre, P. Geach, A. Kenny, P. Foot have tried to follow the Thomas Aquinas School which they use as a source to surpass the Cartesian Epistemology and to develop the virtue ethics. Recently, J. Haldane has inaugurated a program of “analytical thomism” which main result until the present has been his “theory of identity mind/world”. Nevertheless, none of Thomás’ admirers has still found the means of assimilating his metaphysics of being.

  11. Efficiency measurements for 3D silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parzefall, Ulrich, E-mail: ulrich.parzefall@physik.uni-freiburg.d [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Dalla Betta, Gian-Franco [INFN Trento and Universita di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Boscardin, Maurizio [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Eckert, Simon [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Eklund, Lars; Fleta, Celeste [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Jakobs, Karl; Koehler, Michael; Kuehn, Susanne; Pahn, Gregor [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Parkes, Chris; Pennicard, David [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Ronchin, Sabina [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Zoboli, Andrea [INFN Trento and Universita di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Zorzi, Nicola [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy)

    2010-11-01

    Silicon strip detectors are widely used as part of the inner tracking layers in particle physics experiments. For applications at the luminosity upgrade of the Large Hadron Collider (LHC), the sLHC, silicon detectors with extreme radiation hardness are required. The 3D detector design, where electrodes are processed from underneath the strips into the silicon bulk material, provides a way to enhance the radiation tolerance of standard planar silicon strip detectors. Detectors with several innovative 3D designs that constitute a simpler and more cost-effective processing than the 3D design initially proposed were connected to read-out electronics from LHC experiments and subsequently tested. Results on the amount of charge collected, the noise and the uniformity of charge collection are given.

  12. First results from a silicon-strip detector with VLSI readout

    International Nuclear Information System (INIS)

    Anzivino, G.; Horisberger, R.; Hubbeling, L.; Hyams, B.; Parker, S.; Breakstone, A.; Litke, A.M.; Walker, J.T.; Bingefors, N.

    1986-01-01

    A 256-strip silicon detector with 25 μm strip pitch, connected to two 128-channel NMOS VLSI chips (Microplex), has been tested using straight-through tracks from a ruthenium beta source. The readout channels have a pitch of 47.5 μm. A single multiplexed output provides voltages proportional to the integrated charge from each strip. The most probable signal height from the beta traversals is approximately 14 times the rms noise in any single channel. (orig.)

  13. Facilitating Multiple Intelligences Through Multimodal Learning Analytics

    Directory of Open Access Journals (Sweden)

    Ayesha PERVEEN

    2018-01-01

    Full Text Available This paper develops a theoretical framework for employing learning analytics in online education to trace multiple learning variations of online students by considering their potential of being multiple intelligences based on Howard Gardner’s 1983 theory of multiple intelligences. The study first emphasizes the need to facilitate students as multiple intelligences by online education systems and then suggests a framework of the advanced form of learning analytics i.e., multimodal learning analytics for tracing and facilitating multiple intelligences while they are engaged in online ubiquitous learning. As multimodal learning analytics is still an evolving area, it poses many challenges for technologists, educationists as well as organizational managers. Learning analytics make machines meet humans, therefore, the educationists with an expertise in learning theories can help technologists devise latest technological methods for multimodal learning analytics and organizational managers can implement them for the improvement of online education. Therefore, a careful instructional design based on a deep understanding of students’ learning abilities, is required to develop teaching plans and technological possibilities for monitoring students’ learning paths. This is how learning analytics can help design an adaptive instructional design based on a quick analysis of the data gathered. Based on that analysis, the academicians can critically reflect upon the quick or delayed implementation of the existing instructional design based on students’ cognitive abilities or even about the single or double loop learning design. The researcher concludes that the online education is multimodal in nature, has the capacity to endorse multiliteracies and, therefore, multiple intelligences can be tracked and facilitated through multimodal learning analytics in an online mode. However, online teachers’ training both in technological implementations and

  14. Differences in the Theory of Mind profiles of patients with anorexia nervosa and individuals on the autism spectrum: A meta-analytic review.

    Science.gov (United States)

    Leppanen, Jenni; Sedgewick, Felicity; Treasure, Janet; Tchanturia, Kate

    2018-07-01

    This meta-analytic review examines the theory of mind profiles in both patients with anorexia nervosa (AN) and autistic individuals. The studies examining theory of mind were divided into the following categories: emotional theory of mind, understanding simple social situations, understanding complex social interactions, and implicit social attribution. All included studies investigated differences between healthy control (HCs) individuals and people with AN or autistic people. Differences in theory of mind profile between people with AN and autistic people were explored by conducting moderator analyses. People with AN and autistic people showed a similar theory of mind profile, but autistic individuals showed greater difficulties, particularly in emotional theory of mind. Although both people with AN and autistic people have significant difficulties in all aspects of theory of mind relative to the HCs, some differences in the underlying profile may be present. However, due to relative paucity of theory of mind research among people with AN, further research is still needed before firm conclusion can be drawn. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  15. Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors

    CERN Document Server

    Losel, Philipp Jonathan; The ATLAS collaboration

    2015-01-01

    Resisitve strip Micromegas detectors behave discharge tolerant. They have been tested extensively as smaller detectors of about 10 x 10 cm$^2$ in size and they work reliably at high rates of 100\\,kHz/cm$^2$ and above. Tracking resolutions well below 100\\,$\\mu$m have been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3\\,m$^2$ in size. To investigate possible differences between small and large detectors, a 1\\,m$^2$ detector with 2048 resistive strips at a pitch of 450 $\\mu$m was studied in the LMU Cosmic Ray Facility (CRF) using two 4 $\\times$ 2.2 m$^2$ large Monitored Drift Tube (MDT) chambers for cosmic muon reference tracking. Segmentation of the resistive strip anode plane in 57.6\\,mm x 95\\,mm large areas has been realized by the readout of 128 strips with one APV25 chip each and by 11 95\\,mm broad trigger scintillators placed along the readout strips.\\\\ This allows for mapping of homogenity in pulse height and efficiency, deter...

  16. Humor in elementary science: Development and evaluation of comic strips about sound

    Directory of Open Access Journals (Sweden)

    Ertuğrul Özdemir

    2017-06-01

    Full Text Available Comic strips on newspapers, magazines and Internet are one of the most accessible materials that may be used in science classroom as instructional tool. However, it is sometimes difficult to find and adapt appropriate comic strips useful for instructional purposes, because most of them are irrelevant. The purpose of this study is to develop and evaluate instructional comic strips aiming to contribute learning about sound related concepts. In this study, a series of instructional comic strips were created and implemented to a group of seventh grade students. Students’ responses to a number of open-ended questions were evaluated through qualitative content analysis. According to results, most of the students believed that comic strips help learning through simplifying science concepts and making retention of them easier. In addition, comic strips seemed to contribute students’ enjoyment toward science and perception of success in science.

  17. Multiple scattering of MeV ions: Comparison between the analytical theory and Monte-Carlo and molecular dynamics simulations

    International Nuclear Information System (INIS)

    Mayer, M.; Arstila, K.; Nordlund, K.; Edelmann, E.; Keinonen, J.

    2006-01-01

    Angular and energy distributions due to multiple small angle scattering were calculated with different models, namely from the analytical Szilagyi theory, the Monte-Carlo code MCERD in binary collision approximation and the molecular dynamics code MDRANGE, for 2 MeV 4 He in Au at backscattering geometry and for 20 MeV 127 I recoil analysis of carbon. The widths and detailed shapes of the distributions are compared, and reasons for deviations between the different models are discussed

  18. Performance of a new test strip for freestyle blood glucose monitoring systems.

    Science.gov (United States)

    Lock, John Paul; Brazg, Ronald; Bernstein, Robert M; Taylor, Elizabeth; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Chen, Ting; Welsh, Zoë; Amor, Walter; Bhogal, Claire; Ng, Ronald

    2011-01-01

    a new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. for glucose concentrations blood glucose results obtained by lay users fell within ± 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations ≥75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within  ±  5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.

  19. LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes.

    Science.gov (United States)

    Economou, Anastasios; Voulgaropoulos, Anastasios

    2003-01-01

    The development of a dedicated automated sequential-injection analysis apparatus for anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (AdSV) is reported. The instrument comprised a peristaltic pump, a multiposition selector valve and a home-made potentiostat and used a mercury-film electrode as the working electrodes in a thin-layer electrochemical detector. Programming of the experimental sequence was performed in LabVIEW 5.1. The sequence of operations included formation of the mercury film, electrolytic or adsorptive accumulation of the analyte on the electrode surface, recording of the voltammetric current-potential response, and cleaning of the electrode. The stripping step was carried out by applying a square-wave (SW) potential-time excitation signal to the working electrode. The instrument allowed unattended operation since multiple-step sequences could be readily implemented through the purpose-built software. The utility of the analyser was tested for the determination of copper(II), cadmium(II), lead(II) and zinc(II) by SWASV and of nickel(II), cobalt(II) and uranium(VI) by SWAdSV.

  20. Using meta-analytic path analysis to test theoretical predictions in health behavior: An illustration based on meta-analyses of the theory of planned behavior

    OpenAIRE

    Hagger, Martin; Chan, Dervin K. C.; Protogerou, Cleo; Chatzisarantis, Nikos L. D.

    2016-01-01

    Objective Synthesizing research on social cognitive theories applied to health behavior is an important step in the development of an evidence base of psychological factors as targets for effective behavioral interventions. However, few meta-analyses of research on social cognitive theories in health contexts have conducted simultaneous tests of theoretically-stipulated pattern effects using path analysis. We argue that conducting path analyses of meta-analytic effects among constructs fr...

  1. A design aid for sizing filter strips using buffer area ratio

    Science.gov (United States)

    M.G. Dosskey; M.J. Helmers; D.E. Eisenhauer

    2011-01-01

    Nonuniform field runoff can reduce the effectiveness of filter strips that are a uniform size along a field margin. Effectiveness can be improved by placing more filter strip where the runoff load is greater and less where the load is smaller. A modeling analysis was conducted of the relationship between pollutant trapping efficiency and the ratio of filter strip area...

  2. Answer first: Applying the heuristic-analytic theory of reasoning to examine student intuitive thinking in the context of physics

    OpenAIRE

    Mila Kryjevskaia; MacKenzie R. Stetzer; Nathaniel Grosz

    2014-01-01

    We have applied the heuristic-analytic theory of reasoning to interpret inconsistencies in student reasoning approaches to physics problems. This study was motivated by an emerging body of evidence that suggests that student conceptual and reasoning competence demonstrated on one task often fails to be exhibited on another. Indeed, even after instruction specifically designed to address student conceptual and reasoning difficulties identified by rigorous research, many undergraduate physics s...

  3. Analytical vs. Simulation Solution Techniques for Pulse Problems in Non-linear Stochastic Dynamics

    DEFF Research Database (Denmark)

    Iwankiewicz, R.; Nielsen, Søren R. K.

    Advantages and disadvantages of available analytical and simulation techniques for pulse problems in non-linear stochastic dynamics are discussed. First, random pulse problems, both those which do and do not lead to Markov theory, are presented. Next, the analytical and analytically-numerical tec......Advantages and disadvantages of available analytical and simulation techniques for pulse problems in non-linear stochastic dynamics are discussed. First, random pulse problems, both those which do and do not lead to Markov theory, are presented. Next, the analytical and analytically...

  4. Science comic-strips on display at Microcosm

    CERN Document Server

    Alix Marcastel

    2011-01-01

    To mark the publication of his new comic-strip "Les Vies de Marie Curie", the Genevan artist Fiami will be placing some of his previous creations on the theme "women and science" on display at CERN. The new comic-strip pays tribute to the illustrious Nobel prize-winner by taking a light-hearted look at the history of chemistry and how the role of women scientists in society has evolved through the ages.   It's no easy task,  presenting the history of science to the general public in a light-hearted way. As part of the various events organised in the Fête de la Science and the Europeans Researchers Night, CERN will be hosting an exhibition entirely devoted to the comic-strips created by Fiami. The artist describes his comics as "a relaxed way of looking at serious and apparently highly complex subjects."  Fiami's very latest creation, Les Vies de Marie Curie, published in June 2011, celebrates th...

  5. Policy-Making Theory as an Analytical Framework in Policy Analysis: Implications for Research Design and Professional Advocacy.

    Science.gov (United States)

    Sheldon, Michael R

    2016-01-01

    Policy studies are a recent addition to the American Physical Therapy Association's Research Agenda and are critical to our understanding of various federal, state, local, and organizational policies on the provision of physical therapist services across the continuum of care. Policy analyses that help to advance the profession's various policy agendas will require relevant theoretical frameworks to be credible. The purpose of this perspective article is to: (1) demonstrate the use of a policy-making theory as an analytical framework in a policy analysis and (2) discuss how sound policy analysis can assist physical therapists in becoming more effective change agents, policy advocates, and partners with other relevant stakeholder groups. An exploratory study of state agency policy responses to address work-related musculoskeletal disorders is provided as a contemporary example to illustrate key points and to demonstrate the importance of selecting a relevant analytical framework based on the context of the policy issue under investigation. © 2016 American Physical Therapy Association.

  6. The Argonne silicon strip-detector array

    Energy Technology Data Exchange (ETDEWEB)

    Wuosmaa, A H; Back, B B; Betts, R R; Freer, M; Gehring, J; Glagola, B G; Happ, Th; Henderson, D J; Wilt, P [Argonne National Lab., IL (United States); Bearden, I G [Purdue Univ., Lafayette, IN (United States). Dept. of Physics

    1992-08-01

    Many nuclear physics experiments require the ability to analyze events in which large numbers of charged particles are detected and identified simultaneously, with good resolution and high efficiency, either alone, or in coincidence with gamma rays. The authors have constructed a compact large-area detector array to measure these processes efficiently and with excellent energy resolution. The array consists of four double-sided silicon strip detectors, each 5x5 cm{sup 2} in area, with front and back sides divided into 16 strips. To exploit the capability of the device fully, a system to read each strip-detector segment has been designed and constructed, based around a custom-built multi-channel preamplifier. The remainder of the system consists of high-density CAMAC modules, including multi-channel discriminators, charge-sensing analog-to-digital converters, and time-to-digital converters. The array`s performance has been evaluated using alpha-particle sources, and in a number of experiments conducted at Argonne and elsewhere. Energy resolutions of {Delta}E {approx} 20-30 keV have been observed for 5 to 8 MeV alpha particles, as well as time resolutions {Delta}T {<=} 500 ps. 4 figs.

  7. Analytical transmissibility based transfer path analysis for multi-energy-domain systems using four-pole parameter theory

    Science.gov (United States)

    Mashayekhi, Mohammad Jalali; Behdinan, Kamran

    2017-10-01

    The increasing demand to minimize undesired vibration and noise levels in several high-tech industries has generated a renewed interest in vibration transfer path analysis. Analyzing vibration transfer paths within a system is of crucial importance in designing an effective vibration isolation strategy. Most of the existing vibration transfer path analysis techniques are empirical which are suitable for diagnosis and troubleshooting purpose. The lack of an analytical transfer path analysis to be used in the design stage is the main motivation behind this research. In this paper an analytical transfer path analysis based on the four-pole theory is proposed for multi-energy-domain systems. Bond graph modeling technique which is an effective approach to model multi-energy-domain systems is used to develop the system model. In this paper an electro-mechanical system is used as a benchmark example to elucidate the effectiveness of the proposed technique. An algorithm to obtain the equivalent four-pole representation of a dynamical systems based on the corresponding bond graph model is also presented in this paper.

  8. Determination of residual stresses in roll compacted titanium strips

    CSIR Research Space (South Africa)

    Mothosi, KL

    2017-01-01

    Full Text Available residual stresses using x-ray diffraction (XRD) surface probing technique. Preliminary results were obtained for the surface residual stress at the center of the titanium strips for the 100 and 325 mesh strips rolled at 0.1 roll gap for 20 and 50 mm set...

  9. Optimising carbon electrode materials for adsorptive stripping voltammetry

    OpenAIRE

    Chaisiwamongkhol, K; Batchelor-McAuley, C; Sokolov, S; Holter, J; Young, N; Compton, R

    2017-01-01

    Different types of carbon electrode materials for adsorptive stripping voltammetry are studied through the use of cyclic voltammetry. Capsaicin is utilised as a model compound for adsorptive stripping voltammetry using unmodified and modified basal plane pyrolytic graphite (BPPG) electrodes modified with multi-walled carbon nanotubes, carbon black or graphene nanoplatelets, screen printed carbon electrodes (SPE), carbon nanotube modified screen printed electrodes, and carbon paste electrodes....

  10. Method of stripping solid particles

    International Nuclear Information System (INIS)

    1980-01-01

    A method of stripping loaded solid particles is specified in which uniform batches of the loaded particles are passed successively upwardly through an elution column in the form of discrete plugs, the particles of which do not intermingle substantially with the particles of the vertically adjacent plug(s), and are contacted therein with eluant liquid flowed downwardly, strong eluate being withdrawn from the lower region of the column, the loaded particles being supplied as a slurry in a carrier liquid, and successive batches of loaded particles being isolated as measured batches and being separated from their carrier liquid before being contacted with strong eluate and slurried with the strong eluate into the lower region of the column. An example describes the stripping of ion exchange resin particles loaded with complex uranium ions. (author)

  11. Large deformation of uniaxially loaded slender microbeams on the basis of modified couple stress theory: Analytical solution and Galerkin-based method

    Science.gov (United States)

    Kiani, Keivan

    2017-09-01

    Large deformation regime of micro-scale slender beam-like structures subjected to axially pointed loads is of high interest to nanotechnologists and applied mechanics community. Herein, size-dependent nonlinear governing equations are derived by employing modified couple stress theory. Under various boundary conditions, analytical relations between axially applied loads and deformations are presented. Additionally, a novel Galerkin-based assumed mode method (AMM) is established to solve the highly nonlinear equations. In some particular cases, the predicted results by the analytical approach are also checked with those of AMM and a reasonably good agreement is reported. Subsequently, the key role of the material length scale on the load-deformation of microbeams is discussed and the deficiencies of the classical elasticity theory in predicting such a crucial mechanical behavior are explained in some detail. The influences of slenderness ratio and thickness of the microbeam on the obtained results are also examined. The present work could be considered as a pivotal step in better realizing the postbuckling behavior of nano-/micro- electro-mechanical systems consist of microbeams.

  12. Potentiometric stripping analysis of Cadmium and Lead in superficial waters

    International Nuclear Information System (INIS)

    Arias, Juan Miguel; Marciales Castiblanco, Clara

    2003-01-01

    This paper contains the implementation and validation of an analytical method for determining cadmium and lead in surface waters. This is a valuable tool for the description of actual conditions and qualitative and quantitative control of dangerous heavy metals discharge in water bodies. Test were run for selecting stripping potentiometry conditions that as indicated by results were: sample oxidant concentration 36.4 μg/L Hg 2+ stirring frequency 2400 rpm, electrolysis time 80 s., electrolysis potential -950 mV and pH of 2.0. Interference of Cu 2+ and Fe 2+ showed that copper concentrations larger than 150 μg/L and 500 μg/L negatively influence the analytical response for Cadmium and lead respectively; [Fe 3+ ] larger than 60 μg/L and 400 μg/L cause variations in cadmium and lead read content respectively. Linear concentration range for cadmium lies between 5 and 250 μg/L; for lead range goes from 10 to 250 μg/L. Precision expressed as repeatability for both system and method, exhibit good reproducibility with variation coefficients below 6%. Accuracy, assessed from recuperation, is strongly influenced by concentration level therefore standard addition is recommended for lead and cadmium quantification. Analysis performed on surface waters from Colombian Magdalena and Cauca rivers pointed lead and cadmium contents below detection limits

  13. Process for recovering uranium using an alkyl pyrophosphoric acid and alkaline stripping solution

    International Nuclear Information System (INIS)

    Worthington, R.E.; Magdics, A.

    1987-01-01

    A process is described for stripping uranium for a pregnant organic extractant comprising an alkyl pyrophosphoric acid dissolved in a substantially water-immiscible organic diluent. The organic extractant contains tetravalent uranium and an alcohol or phenol modifier in a quantity sufficient to retain substantially all the unhydrolyzed alkyl pyrophosphoric acid in solution in the diluent during stripping. The process comprises adding an oxidizing agent to the organic extractant and thereby oxidizing the tetravalent uranium to the +6 state in the organic extractant, and contacting the organic extractant containing the uranium in the +6 state with a stripping solution comprising an aqueous solution of an alkali metal or ammonium carbonate or hydroxide thereby stripping uranium from the organic extractant into the stripping solution. The resulting barren organic extractant containing substantially all of the unhydrolyzed alkyl pyrophosphoric acid dissolved in the diluent is separated from the stripping solution containing the stripped uranium, the barren extractant being suitable for recycle

  14. Analytic first derivatives for a spin-adapted open-shell coupled cluster theory: Evaluation of first-order electrical properties

    Energy Technology Data Exchange (ETDEWEB)

    Datta, Dipayan, E-mail: datta@uni-mainz.de; Gauss, Jürgen, E-mail: gauss@uni-mainz.de [Institut für Physikalische Chemie, Johannes Gutenberg-Universität Mainz, Duesbergweg 10-14, D-55128 Mainz (Germany)

    2014-09-14

    An analytic scheme is presented for the evaluation of first derivatives of the energy for a unitary group based spin-adapted coupled cluster (CC) theory, namely, the combinatoric open-shell CC (COSCC) approach within the singles and doubles approximation. The widely used Lagrange multiplier approach is employed for the derivation of an analytical expression for the first derivative of the energy, which in combination with the well-established density-matrix formulation, is used for the computation of first-order electrical properties. Derivations of the spin-adapted lambda equations for determining the Lagrange multipliers and the expressions for the spin-free effective density matrices for the COSCC approach are presented. Orbital-relaxation effects due to the electric-field perturbation are treated via the Z-vector technique. We present calculations of the dipole moments for a number of doublet radicals in their ground states using restricted open-shell Hartree-Fock (ROHF) and quasi-restricted HF (QRHF) orbitals in order to demonstrate the applicability of our analytic scheme for computing energy derivatives. We also report calculations of the chlorine electric-field gradients and nuclear quadrupole-coupling constants for the CCl, CH{sub 2}Cl, ClO{sub 2}, and SiCl radicals.

  15. Observational study on the pavement performance effects of shoulder rumble strip on shoulders

    Directory of Open Access Journals (Sweden)

    Sean Coffey

    2016-07-01

    Full Text Available Rumble strip implementation has shown a constant increase with its safety benefits. Rumble strips are milled into the roadway shoulder to produce noise and vibrations when driven on. With the milling process, the pavement performance is expected to be negatively impacted by the decreased depth, though not mathematically quantified. Using methods defined by the Long-Term Pavement Performance Program, the severity of the shoulder site’s distresses, with and without shoulder rumble strips, will be quantified. The quantification would permit the design to compensate for the impact. This design compensation allows the implementation of hard shoulder running, the use of shoulder as a travel lane during congestion, and retains the shoulder rumble strip safety instead of removing, as suggested by some proposed projects. While hard shoulder running would not impact specific time periods, the safety benefit of rumble strips could be needed at any time. This study aims to quantify the rumble strip impact to enable the full shoulder strength for hard shoulder running while retaining the safety benefits of rumble strips. Keywords: Rumble strips, Shoulder, Cracking, Pavement performance, Hard shoulder running

  16. slice of LEP beamtube with getter strip

    CERN Multimedia

    1989-01-01

    A section of the LEP beam pipe. This is the chamber in which LEP's counter-rotating electron and positron beams travel. It is made of lead-clad aluminium. The beams circulate in the oval cross-section part of the chamber. In the rectangular cross-section part, LEP's innovative getter-strip vacuum pump is installed. After heating to purify the surface of the getter, the strip acts like molecular sticky tape, trapping any stray molecules left behind after the accelerator's traditional vacuum pumps have done their job.

  17. Herbert Marcuse's Critical Theory of the Media.

    Science.gov (United States)

    Daley, Patrick J.

    As a member of the Frankfurt School of critical theory, Herbert Marcuse believed that industrial capitalism and the bureaucratization of society stripped humans of any claims to autonomy and undermined their critical expression with a functional language. However, Marcuse did no more than point an inchoate ideological finger at the production side…

  18. Influence for high intensity irradiation on characteristics of silicon strip-detectors

    International Nuclear Information System (INIS)

    Anokhin, I.E.; Pugatch, V.M.; Zinets, O.S.

    1995-01-01

    Full text: Silicon strip detectors (SSD) are widely used for the coordinate determination of short-range as well as minimum ionizing particles with high spatial resolution. Submicron position sensitivity of strip-detectors for short-range particles has been studied by means of two dimensional analyses of charges collected by neighboring strips as well as by measurement of charge collection times [1]. Silicon strip detectors was also used for testing high energy electron beam [2]. Under large fluences the radiation defects are stored and such characteristics of strip-detectors as an accuracy of the coordinate determination and the registration efficiency are significantly changed. Radiation defects lead to a decrease of the lifetime and mobility of charge carriers and therefore to changes of conditions for the charge collection in detectors. The inhomogeneity in spatial distribution if defects and electrical field plays an important role in the charge collection. In this report the role of the diffusion and drift in the charge collection in silicon strip-detectors under irradiation up to 10 Mrad has been studied. The electric field distribution and its dependence on the radiation dose in the detector have been calculated. It is shown that for particles incident between adjacent strips the coordinate determination precision depends strongly on the detector geometry and the electric field distribution, particularly in the vicinity of strips. Measuring simultaneously the collected charges and collection times on adjacent strips one can essentially improve reliability of the coordinate determination for short-range particles. Usually SSD are fabricated on n-type wafers. It is well known that under high intensity irradiation n-Si material converts into p-Si as far as p-type silicon is more radiative hard than n-type silicon [3] it is reasonable to fabricate SSD using high resistivity p-Si. Characteristics of SSD in basis n-and P-Si have been compared and higher

  19. Comparisons of boll weevil (Coleoptera: Curculionidae) pheromone traps with and without kill strips.

    Science.gov (United States)

    Suh, C P C; Armstrong, J S; Spurgeon, D W; Duke, S

    2009-02-01

    Boll weevil, Anthonomus grandis grandis Boheman (Coleoptera: Curculionidae), eradication programs typically equip pheromone traps with an insecticide-impregnated kill strip. These strips are intended to kill captured insects, thereby simplifying trap servicing and reducing the loss of weevils from predation and escape. However, the effectiveness of kill strips has not been extensively evaluated. We examined the influences of kill strips on weevil captures, trap servicing, and the incidences of weevil predation and trap obstruction (e.g., by spider webs). Evaluations were conducted weekly during three different production periods (pre- to early-, late-, and postseason) of cotton, Gossypium hirsutum L., to represent different environmental conditions and weevil population levels. Within each period, mean weekly captures of weevils in traps with and without kill strips were statistically similar. On average, traps with kill strips took 9 s longer to service than traps without kill strips, but statistical differences were only detected during the late-season period. Overall, the mean weekly proportion of traps with evidence of weevil predation or trap obstruction was significantly lower for traps with kill strips (0.25) than for traps without kill strips (0.37). However, this reduction in the frequency of weevil predation or trap obstruction was too small to produce a corresponding increase in the numbers of weevils captured. In light of these findings, the use of kill strips is likely unnecessary in eradication programs, but may be a consideration in situations when the numbers of deployed traps are reduced and chronic problems with weevil predation or trap obstruction exist.

  20. Generalized analytic continuation

    CERN Document Server

    Ross, William T

    2002-01-01

    The theory of generalized analytic continuation studies continuations of meromorphic functions in situations where traditional theory says there is a natural boundary. This broader theory touches on a remarkable array of topics in classical analysis, as described in the book. This book addresses the following questions: (1) When can we say, in some reasonable way, that component functions of a meromorphic function on a disconnected domain, are "continuations" of each other? (2) What role do such "continuations" play in certain aspects of approximation theory and operator theory? The authors use the strong analogy with the summability of divergent series to motivate the subject. In this vein, for instance, theorems can be described as being "Abelian" or "Tauberian". The introductory overview carefully explains the history and context of the theory. The authors begin with a review of the works of Poincaré, Borel, Wolff, Walsh, and Gončar, on continuation properties of "Borel series" and other meromorphic func...

  1. Analytic scattering theory of quantum mechanical three-body systems

    International Nuclear Information System (INIS)

    Balslev, Erik

    1980-01-01

    We consider a three-body Schroedinger operator H=H 0 +V in L 2 (Rsup(2n)), where V=Σ Vsub(α) and each Vsub(α) is a dilation-analytic two-body interaction decreasing faster than rsup(-β), where β>1 for negative energies and β>2 for positive energies. Together with H we consider the associated self-adjoint analytic family of operator given in momentum space by H(z)=z 2 H 0 +V(z), /Arg z/ 0 , H). The local inverse wave operators are constructed and asymptotic completeness proved. The full S-matrix S(μ) and for phi not equal to 0 the channel S-matrices are expressed in terms of boundary values of the resolvent. It is proved that the function is an analytic continuation into the lower half-plane of the diagonal element with poles at most at resolvent resonances and, under some reasonable assumptions, precisely at these resonances

  2. Distortions in angular correlations for low energy stripping reactions in light nuclei

    International Nuclear Information System (INIS)

    Karfunkel, U.; Sellschop, J.P.F.; Stemmet, M.C.

    1974-07-01

    Angular correlation techniques are a sensitive probe for determining distortions from simple stripping reactions. Fifteen angular correlations were measured for 11 B(d,pgamma) 12 B*(0.95 MeV), and fitted by a two-parameter angular correlation function W(theta(gamma)) = 1 + A 2 P 2 [ cos (theta(gamma) - phi(o))]. If distortions from the predictions of plane wave theory occur, the deviation delta phi = phi(R) - phi(o) of the recoil axis of the residual nucleus from the measured symmetry axis phi(o) will possibly differ from zero, while the anisotropy A 2 on the other hand is expected to be attenuated relative to its maximum possible PWBA value. The measurements show A 2 to rise sharply at backward angles, and delta phi to be rather small and constant throughout, both of which conflict with expectations based on previously published measurements. A discussion of the results in the light of different possible processes and existing theories is carried out

  3. Asymmetric driven dynamics of Dzyaloshinskii domain walls in ultrathin ferromagnetic strips with perpendicular magnetic anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Sánchez-Tejerina, L. [Dpto. Electricidad y Electrónica, Facultad de Ciencias, Universidad de Valladolid, 47011 Valladolid (Spain); Alejos, Ó., E-mail: oscaral@ee.uva.es [Dpto. Electricidad y Electrónica, Facultad de Ciencias, Universidad de Valladolid, 47011 Valladolid (Spain); Martínez, E. [Dpto. Física Aplicada, Facultad de Ciencias, Universidad de Salamanca, 37011 Salamanca (Spain); Muñoz, J.M. [Dpto. Electricidad y Electrónica, Facultad de Ciencias, Universidad de Valladolid, 47011 Valladolid (Spain)

    2016-07-01

    The dynamics of domain walls in ultrathin ferromagnetic strips with perpendicular magnetic anisotropy is studied from both numerical and analytical micromagnetics. The influence of a moderate interfacial Dzyaloshinskii–Moriya interaction associated to a bi-layer strip arrangement has been considered, giving rise to the formation of Dzyaloshinskii domain walls. Such walls possess under equilibrium conditions an inner magnetization structure defined by a certain orientation angle that make them to be considered as intermediate configurations between Bloch and Néel walls. Two different dynamics are considered, a field-driven and a current-driven dynamics, in particular, the one promoted by the spin torque due to the spin-Hall effect. Results show an inherent asymmetry associated with the rotation of the domain wall magnetization orientation before reaching the stationary regime, characterized by a constant terminal speed. For a certain initial DW magnetization orientation at rest, the rotation determines whether the reorientation of the DW magnetization prior to reach stationary motion is smooth or abrupt. This asymmetry affects the DW motion, which can even reverse for a short period of time. Additionally, it is found that the terminal speed in the case of the current-driven dynamics may depend on either the initial DW magnetization orientation at rest or the sign of the longitudinally injected current. - Highlights: • The asymmetric response of domain walls in bilayer strips with PMA is studied. • Out-of-plane fields and SHE longitudinal currents are applied. • The response is associated to the rotation of the domain wall inner magnetization. • Clockwise and counter-clockwise magnetization rotations are not equivalent. • The asymmetry results in different travelled distances and/or terminal speeds.

  4. Asymmetric driven dynamics of Dzyaloshinskii domain walls in ultrathin ferromagnetic strips with perpendicular magnetic anisotropy

    International Nuclear Information System (INIS)

    Sánchez-Tejerina, L.; Alejos, Ó.; Martínez, E.; Muñoz, J.M.

    2016-01-01

    The dynamics of domain walls in ultrathin ferromagnetic strips with perpendicular magnetic anisotropy is studied from both numerical and analytical micromagnetics. The influence of a moderate interfacial Dzyaloshinskii–Moriya interaction associated to a bi-layer strip arrangement has been considered, giving rise to the formation of Dzyaloshinskii domain walls. Such walls possess under equilibrium conditions an inner magnetization structure defined by a certain orientation angle that make them to be considered as intermediate configurations between Bloch and Néel walls. Two different dynamics are considered, a field-driven and a current-driven dynamics, in particular, the one promoted by the spin torque due to the spin-Hall effect. Results show an inherent asymmetry associated with the rotation of the domain wall magnetization orientation before reaching the stationary regime, characterized by a constant terminal speed. For a certain initial DW magnetization orientation at rest, the rotation determines whether the reorientation of the DW magnetization prior to reach stationary motion is smooth or abrupt. This asymmetry affects the DW motion, which can even reverse for a short period of time. Additionally, it is found that the terminal speed in the case of the current-driven dynamics may depend on either the initial DW magnetization orientation at rest or the sign of the longitudinally injected current. - Highlights: • The asymmetric response of domain walls in bilayer strips with PMA is studied. • Out-of-plane fields and SHE longitudinal currents are applied. • The response is associated to the rotation of the domain wall inner magnetization. • Clockwise and counter-clockwise magnetization rotations are not equivalent. • The asymmetry results in different travelled distances and/or terminal speeds.

  5. Numerical analysis of edge effects in side illuminated strip detectors for digital radiology

    CERN Document Server

    Krizaj, D

    2000-01-01

    The influence of edge defects on side illuminated X-ray strip detectors for digital radiology is investigated by numerical device modeling. By assuming positive fixed oxide charges on side and top surfaces simulations have shown strong curvature of the equipotential lines in the edge region. A fraction of the edge generated current surpasses the edge guard-ring junction and is collected by the readout strips. As a consequence, strips cannot be placed close to the edge of the structure and collection efficiency is reduced. An n-on-n instead of a p-on-n strip detector is proposed enabling collection of edge generated carriers by a very narrow guard-ring junction and placement of the readout strip close to the edge without increase of the strip leakage current.

  6. Design, Analysis, and On-Sun Evaluation of Reflective Strips Under Controlled Buckling

    Science.gov (United States)

    Jaworske, Donald A.; Sechkar, Edward A.; Colozza, Anthony J.

    2014-01-01

    Solar concentrators are envisioned for use in a variety of space-based applications, including applications involving in situ resource utilization. Identifying solar concentrators that minimize mass and cost are of great interest, especially since launch cost is driven in part by the mass of the payload. Concentrators must also be able to survive the wide temperature excursions on the lunar surface. Identifying smart structures which compensate for changes in concentrator geometry brought about by temperature extremes are of interest. Some applications may benefit from the ability to change the concentrators focal pattern at will. This paper addresses a method of designing a single reflective strip to produce a desired focal pattern through the use of controlled buckling. Small variations in the cross section over the length of the reflective strip influence the distribution of light in the focal region. A finite element method of analysis is utilized here which calculates the curve produced for a given strip cross section and axial load. Varying axial force and strip cross section over the length of the reflective strip provide a means of optimizing ray convergence in the focal region. Careful selection of a tapered cross section yields a reflective strip that approximates a parabola. An array of reflective strips under controlled buckling produces a light weight concentrator and adjustments in the compression of individual strips provide a means of compensating for temperature excursions or changing the focal pattern at will.

  7. Commentary on "Theory-Led Design of Instruments and Representations in Learning Analytics: Developing a Novel Tool for Orchestration of Online Collaborative Learning"

    Science.gov (United States)

    Teplovs, Chris

    2015-01-01

    This commentary reflects on the contributions to learning analytics and theory by a paper that describes how multiple theoretical frameworks were woven together to inform the creation of a new, automated discourse analysis tool. The commentary highlights the contributions of the original paper, provides some alternative approaches, and touches on…

  8. Cathodic adsorptive stripping voltammetric determination of Ribavirin in pharmaceutical dosage form, urine and serum

    Directory of Open Access Journals (Sweden)

    Ahmed A. Abdel Gaber

    2017-05-01

    Full Text Available A sensitive, simple and rapid square-wave adsorptive stripping voltammetric method was developed and validated for the determination of Ribavirin in pharmaceutical formulations. The proposed method was based on the electrochemical reduction of Ribavirin at a hanging mercury drop electrode in Britton Robinson buffer at pH 10. A well-defined peak was observed at 880 mV with 30 s of accumulation time and 50 mV of accumulation potential. Under these optimized conditions, the square-wave adsorptive stripping voltammetric peak current showed a linear correlation on drug concentration over the range of 1 × 10−10–2 × 10−7 mol L−1 with a correlation coefficient of 0.9995 for the proposed method. The detection and quantitation limits for this method were 2.02 × 10−10 and 6.80 × 10−10 mol L−1, respectively. The results obtained for intra-day and inter-day precision (as RSD % were between 0.447% and 1.024%. This method was applied successfully for the determination of Ribavirin in its pharmaceutical dosage forms with mean recoveries of 99.68 ± 0.13 with RSD % of 0.81% and 99.20 ± 0.24 with RSD % of 0.49% for two concentrations 5 × 10−9 and 5 × 10−8 mol L−1, respectively for 200 mg capsules. The results obtained from the developed square-wave adsorptive stripping voltammetric method were compared with those obtained by the analytical method reported in the literature.

  9. Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00389527; The ATLAS collaboration

    2016-01-01

    Resistive strip Micromegas detectors are discharge tolerant. They have been tested extensively as small detectors of about 10 x 10 cm$^2$ in size and they work reliably at high rates of 100 kHz/cm$^2$ and above. Tracking resolution well below 100 $\\mu$m has been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3 m$^2$ in size. To investigate possible differences between small and large detectors, a 1 m$^2$ detector with 2048 resistive strips at a pitch of 450 $\\mu$m was studied in the LMU Cosmic Ray Measurement Facility (CRMF) using two 4 $\\times$ 2.2 m$^2$ large Monitored Drift Tube (MDT) chambers for cosmic muon reference tracking. A segmentation of the resistive strip anode plane in 57.6 mm x 93 mm large areas has been realized by the readout of 128 strips with one APV25 chip each and by eleven 93 mm broad trigger scintillators placed along the readout strips. This allows for mapping of homogeneity in pulse height and efficiency, d...

  10. Silicon Strip Detectors for ATLAS at the HL-LHC Upgrade

    CERN Document Server

    Hara, K; The ATLAS collaboration

    2012-01-01

    The present ATLAS silicon strip (SCT) and transition radiation (TRT) trackers will be replaced with new silicon strip detectors, as part of the Inner Tracker System (ITK), for the Phase-2 upgrade of the Large Hadron Collider, HL-LHC. We have carried out intensive R&D programs to establish radiation harder strip detectors that can survive in a radiation level up to 3000 fb-1 of integrated luminosity based on n+-on-p microstrip detector. We describe main specifications for this year’s sensor fabrication, followed by a description of possible module integration schema

  11. Wide Strip Casting Technology of Magnesium Alloys

    Science.gov (United States)

    Park, W.-J.; Kim, J. J.; Kim, I. J.; Choo, D.

    Extensive investigations relating to the production of high performance and low cost magnesium sheet by strip casting have been performed for the application to automotive parts and electronic devices. Research on magnesium sheet production technology started in 2004 by Research Institute of Industrial Science and Technology (RIST) with support of Pohang Iron and Steel Company (POSCO). POSCO has completed the world's first plant to manufacture magnesium coil. Another big project in order to develop wide strip casting technology for the automotive applications of magnesium sheets was started in succession.

  12. Asset Stripping in a Mature Market Economy

    DEFF Research Database (Denmark)

    Klarskov Jeppesen, Kim; Møller, Ulrik Gorm

    2011-01-01

    Purpose – The purpose of this paper is to document a Danish fraud scheme, in which a large number of limited companies were stripped of their assets leaving them with nothing but tax debt, eventually causing the Danish Tax and Customs Administration to lose large sums. Furthermore, the purpose...... indicates that asset stripping may take place in mature market economies to the extent that perpetrators are able to circumvent the corporate governance system by giving lawyers, public accountants and banks incentives to act less critically towards dubious business transactions. Research limitations...

  13. Apparatus for irradiating a continuous line metallic strip with electron beams

    International Nuclear Information System (INIS)

    Matsuda, Shozo; Tanaka, Tadashi; Okamoto, Tadaaki; Ueno, Nagaharu.

    1970-01-01

    The secondary X-rays from an irradiated object are completely shielded by providing direction-change rollers between applicator rollers and irradiation devices. The substrate strip turns its direction of travel by 90 0 through idle rollers and before it enters a front side applicator roller. After the application of coatings, the strip travels over a roller to turn upwardly, so that the applicator is isolated from the following irradiation enclosure. Next, the irradiated strip changes its direction by 90 0 through a roller to enter a bake side coating applicator. After a direction change through a roller, the strip enters the irradiation enclosure. In this way, the applicators can prevent leakage of secondary X-rays. (Iwakiri, K.)

  14. Performance of strip-based glucose meters and cassette-based blood gas analyzer for monitoring glucose levels in a surgical intensive care setting.

    Science.gov (United States)

    Claerhout, Helena; De Prins, Martine; Mesotten, Dieter; Van den Berghe, Greet; Mathieu, Chantal; Van Eldere, Johan; Vanstapel, Florent

    2016-01-01

    We verified the analytical performance of strip-based handheld glucose meters (GM) for prescription use, in a comparative split-sample protocol using blood gas samples from a surgical intensive care unit (ICU). Freestyle Precision Pro (Abbott), StatStrip Connectivity Meter (Nova), ACCU-CHEK Inform II (Roche) were evaluated for recovery/linearity, imprecision/repeatability. The GMs and the ABL90 (Radiometer) blood gas analyzer (BGA) were tested for relative accuracy vs. the comparator hexokinase glucose-6-phosphate-dehydrogenase (HK/G6PDH) assay on a Cobas c702 analyzer (Roche). Recovery of spiked glucose was linear up to 19.3 mmol/L (347 mg/dL) with a slope of 0.91-0.94 for all GMs. Repeatability estimated by pooling duplicate measurements on samples below (n=9), in (n=51) or above (n=80) the 4.2-5.9 mM (74-106 mg/dL) range were for Freestyle Precision Pro: 4.2%, 4.0%, 3.6%; StatStrip Connectivity Meter: 4.0%, 4.3%, 4.5%; and ACCU-CHEK Inform II: 1.4%, 2.5%, 3.5%. GMs were in agreement with the comparator method. The BGA outperformed the GMs, with a MARD of 3.9% compared to 6.5%, 5.8% and 4.4% for the FreeStyle, StatStrip and ACCU-CHEK, respectively. Zero % of the BGA results deviated more than the FDA 10% criterion as compared to 9.4%, 3.7% and 2.2% for the FreeStyle, StatStrip and ACCU-CHEK, respectively. For all GMs, icodextrin did not interfere. Variation in the putative influence factors hematocrit and O2 tension could not explain observed differences with the comparator method. GMs quantified blood glucose in whole blood at about the 10% total error criterion, proposed by the FDA for prescription use.

  15. 3-D Discrete Analytical Ridgelet Transform

    OpenAIRE

    Helbert , David; Carré , Philippe; Andrès , Éric

    2006-01-01

    International audience; In this paper, we propose an implementation of the 3-D Ridgelet transform: the 3-D discrete analytical Ridgelet transform (3-D DART). This transform uses the Fourier strategy for the computation of the associated 3-D discrete Radon transform. The innovative step is the definition of a discrete 3-D transform with the discrete analytical geometry theory by the construction of 3-D discrete analytical lines in the Fourier domain. We propose two types of 3-D discrete lines:...

  16. stripping of uranium from DEHPA/TOPO solvent by ammonium carbonate solutions

    International Nuclear Information System (INIS)

    Khorfan, S.; Shino, O.; Wahood, A.; Dahdouh, A.

    2002-01-01

    Uranium is recovered from phosphoric acid by the DEHPA/TOPO process. In this process uranium is stripped from the loaded DEHPA/TOPO solvent in the second cycle by an ammonium carbonate solution. This paper studied stripping of uranium from 0.3 Mol DEHPA/0.075 Mol TOPO in kerosene by different ammonium carbonate solutions. The ammonium carbonate solutions tested were either made locally from ammonia and carbon dioxide gases or commercial and laboratory grades available on the market. A comparison was made between these carbonate solutions in terms of purity, stripping efficiency and phase separation. Both stripping and phase separation were carried out under different conditions of phase ratio and concentrations. The results obtained showed that ammonium carbonate prepared from direct synthesis of ammonia and carbon dioxide gases had a high purity and gave the same stripping yield as the laboratory grade. The phase separation was also slightly improved using a pure synthesized ammonium carbonate solution. the phase separation was found to be best at concentration of 0.5 Mol/L ammonium carbonate solution and at a phase A/O of 1/1 and a temperature of 50 degree centigrade. It was possible to obtain >99% yield by operating 2 stripping stages counter currently under these conditions. (authors)

  17. Uniform physical theory of diffraction equivalent edge currents for implementation in general computer codes

    DEFF Research Database (Denmark)

    Johansen, Peter Meincke

    1996-01-01

    New uniform closed-form expressions for physical theory of diffraction equivalent edge currents are derived for truncated incremental wedge strips. In contrast to previously reported expressions, the new expressions are well-behaved for all directions of incidence and observation and take a finite...... value for zero strip length. Consequently, the new equivalent edge currents are, to the knowledge of the author, the first that are well-suited for implementation in general computer codes...

  18. Compton recoil electron tracking with silicon strip detectors

    International Nuclear Information System (INIS)

    O'Neill, T.J.; Ait-Ouamer, F.; Schwartz, I.; Tumer, O.T.; White, R.S.; Zych, A.D.

    1992-01-01

    The application of silicon strip detectors to Compton gamma ray astronomy telescopes is described in this paper. The Silicon Compton Recoil Telescope (SCRT) tracks Compton recoil electrons in silicon strip converters to provide a unique direction for Compton scattered gamma rays above 1 MeV. With strip detectors of modest positional and energy resolutions of 1 mm FWHM and 3% at 662 keV, respectively, 'true imaging' can be achieved to provide an order of magnitude improvement in sensitivity to 1.6 x 10 - 6 γ/cm 2 -s at 2 MeV. The results of extensive Monte Carlo calculations of recoil electrons traversing multiple layers of 200 micron silicon wafers are presented. Multiple Coulomb scattering of the recoil electron in the silicon wafer of the Compton interaction and the next adjacent wafer is the basic limitation to determining the electron's initial direction

  19. VERB-VISUALITY IN MAFALDA’S COMIC STRIP: LINGUISTIC COURTESY/DISCOURTESY AND HUMOR IN THE DIALOGUE OF THE FIGURATIVE NARRATIVE

    Directory of Open Access Journals (Sweden)

    Carlos Augusto Baptista Andrade

    2016-07-01

    Full Text Available How to read a comic strip? What dialogical relations can such a genre perform, considering its hybrid nature of languages? It is proposed, in this article, to analyze a Mafalda’s comic strip, character created by Quino, as a discursive hybrid genre, observing the verb-visuality that constitutes the discourse, as well as exploring the meaning effects that arise from the dialogical relations. The marks of linguistic politeness and impoliteness present in the verb-visual materiality are also an object of this study. The theoretical foundation is the Dialogic Discourse Analysis (ADD, following the principles of Bakhtin (2010a, 2010b and his Circle and Brait’s (2013, as well as Brown and Levinson (1987 as a ground theory to support the issues of courtesy; and Kandinsky (2012 to assist in the reflections about the pictorial elements.

  20. The Analysis of a Wideband Strip-Helical Antenna with 1.1 Turns

    Directory of Open Access Journals (Sweden)

    Xihui Tang

    2016-01-01

    Full Text Available A wideband strip-helical antenna with 1.1 turns is analyzed numerically and experimentally. By replacing the traditional wire helix with wide metallic strip, the forward traveling current on the strip helix with about one turn smoothly decays to the minimum value at the open end of the helix. Therefore, the strip helix can excite a wideband circular polarization (CP wave with 50-ohm impedance matching. The proposed antenna is printed on a hollow-cylinder with a substrate relative permittivity of εr=2.2 and a thickness of h=0.5 mm. A 50 Ω coaxial cable is directly connected to excite the strip-helical antenna without any additional impedance matching section. The ground plane is placed below the antenna in order to provide a directional radiation pattern. To demonstrate this method, a prototype of 1.1-turn strip-helical antenna is tested. The test shows that the proposed antenna can reach an overlapped bandwidth of 46% with height of 0.52λ0, where λ0 is the wavelength in free space at the center operation frequency.

  1. Modules and Front-End Electronics Developments for the ATLAS ITk Strips Upgrade

    CERN Document Server

    Garcia-Argos, Carlos; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment is currently preparing for an upgrade of the tracking system in the course of the High Luminosity LHC, scheduled for 2024. The existing Inner Detector will be replaced by an all-silicon Inner Tracker (ITk) with a pixel detector surrounded by a strip detector. The ITk strip detector consists of a four layer barrel and a forward region composed of six discs on each side of the barrel. The basic unit of the detector is the silicon-strip module, consisting of a sensor and one or more hybrid circuits that hold the read-out electronics. The geometries of the barrel and end-cap modules take into account the regions that they have to cover. In the central region, the detectors are rectangular with straight strips, whereas on the forward region the modules require wedge shaped sensors with varying strip length and pitch. The current prototyping phase has resulted in the ITk Strip Detector Technical Design Report (TDR), which kicks-off the pre-production readiness phase at the involved institutes. ...

  2. Modules and Front-End Electronics Developments for the ATLAS ITk Strips Upgrade

    CERN Document Server

    Garcia-Argos, Carlos; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment is currently preparing for an upgrade of the tracking system in the course of the High Luminosity LHC, scheduled for 2024. The existing Inner Detector will be replaced by an all-silicon Inner Tracker (ITk) with a pixel detector surrounded by a strip detector. The ITk strip detector consists of a four layer barrel and a forward region composed of six discs on each side of the barrel. The basic unit of the detector is the silicon-strip module, consisting of a sensor and one or more hybrid circuits that hold the read-out electronics. The geometries of the barrel and end-cap modules take into account the regions that they have to cover. In the central region, the detectors are rectangular with straight strips, whereas in the forward region the modules require wedge shaped sensors with varying strip length and pitch. The current prototyping phase has resulted in the ITk Strip Detector Technical Design Report (TDR), which kicks-off the pre-production readiness phase at the involved institutes. ...

  3. On operads, bimodules and analytic functors

    CERN Document Server

    Gambino, Nicola

    2017-01-01

    The authors develop further the theory of operads and analytic functors. In particular, they introduce the bicategory \\operatorname{OpdBim}_{\\mathcal{V}} of operad bimodules, that has operads as 0-cells, operad bimodules as 1-cells and operad bimodule maps as 2-cells, and prove that it is cartesian closed. In order to obtain this result, the authors extend the theory of distributors and the formal theory of monads.

  4. Dual deflectable beam strip engine development.

    Science.gov (United States)

    Dulgeroff, C. R.; Zuccaro, D. E.; Kami, S.; Schnelker, D. E.; Ward, J. W.

    1972-01-01

    This paper describes a dual beam thruster that has been designed, constructed, and tested. The system is suitable for two-axes attitude control and is comprised of two orthogonal strips, each capable of producing 0.30 mlb thrust and beam deflections of more than plus or minus 20 deg. The nominal specific impulse for the thruster is 5000 sec, and the thrust level from each strip can be varied from 0 to 100%. Neutralizer filaments that were developed and life tested over 2000 hours producing more than 40 mA of electron emission per watt of input power are also discussed. The system power required for clean ionizers is approximately 200 W.

  5. PECULIAR FEATURES PERTAINING TO STRIP FORMATION FROM BAR

    Directory of Open Access Journals (Sweden)

    G. N. Zdor

    2010-01-01

    Full Text Available The paper describes results of calculations and presents experimental substantiation of the dependence of a strip width being rolled out of a 10-mm diameter bar on its final thickness. It has been shown that the formation technology of thin steel strips out of a round bar makes it possible without any difficulties to obtain rolled products with the given cross-section dimensions due to proper selection of single drafting.

  6. Teaching Theory Construction With Initial Grounded Theory Tools: A Reflection on Lessons and Learning.

    Science.gov (United States)

    Charmaz, Kathy

    2015-12-01

    This article addresses criticisms of qualitative research for spawning studies that lack analytic development and theoretical import. It focuses on teaching initial grounded theory tools while interviewing, coding, and writing memos for the purpose of scaling up the analytic level of students' research and advancing theory construction. Adopting these tools can improve teaching qualitative methods at all levels although doctoral education is emphasized here. What teachers cover in qualitative methods courses matters. The pedagogy presented here requires a supportive environment and relies on demonstration, collective participation, measured tasks, progressive analytic complexity, and accountability. Lessons learned from using initial grounded theory tools are exemplified in a doctoral student's coding and memo-writing excerpts that demonstrate progressive analytic development. The conclusion calls for increasing the number and depth of qualitative methods courses and for creating a cadre of expert qualitative methodologists. © The Author(s) 2015.

  7. Perturbation Theory of Embedded Eigenvalues

    DEFF Research Database (Denmark)

    Engelmann, Matthias

    project gives a general and systematic approach to analytic perturbation theory of embedded eigenvalues. The spectral deformation technique originally developed in the theory of dilation analytic potentials in the context of Schrödinger operators is systematized by the use of Mourre theory. The group...... of dilations is thereby replaced by the unitary group generated y the conjugate operator. This then allows to treat the perturbation problem with the usual Kato theory.......We study problems connected to perturbation theory of embedded eigenvalues in two different setups. The first part deals with second order perturbation theory of mass shells in massive translation invariant Nelson type models. To this end an expansion of the eigenvalues w.r.t. fiber parameter up...

  8. Laser stripping of relativistic H- ions with practical considerations

    International Nuclear Information System (INIS)

    Tomlin, R.

    1995-12-01

    This paper describes laser stripping of H - ions. Some applications are suggested for HEP including stripping 2GeV ions circulating in an accelerator with radius 75 meters where laser meets ion head on in a three meter interaction region. The paper describes photoionizaton cross section, laser power calculation, and how to generate the 5 micrometer light

  9. The Las Vegas Strip as a Genuinely Invented Global Landscape

    Directory of Open Access Journals (Sweden)

    Daniel Ortega

    2004-12-01

    Full Text Available Las Vegas, Nevada, is typically recognised as a place via a single urban gesture, that gesture being Las Vegas Boulevard, which is more commonly referred to as "The Strip". In constructing a thesis around the theme, "Here or There? Interconnections between the Global and the Local", one cannot ignore the invitation to discuss globalisation and its effects on a particular local fabric. For the purpose of this text, globalisation can be thought of as what Carmona et al describe as an intricate series of events leading to the world "becoming increasingly interconnected, with centralised decision making exploiting economies of scale and standardisation" (2003: 101. The centralised decision-making process for The Strip is evident in the strategy to develop individually themed casino resorts along Las Vegas Boulevard that respond to a competitive economy, thus creating a newly standardised landscape. If we also understand that globalisation can be thought of as the development of an interconnected world where economic, political and cultural boundaries can be easily crossed, this work can begin to define how the Las Vegas Strip is a genuinely invented global landscape. This paper addresses the "here-ness" as well as the "there-ness" of The Strip, while offering a dialectical framework for establishing a meaning of place by having 'there' placed 'here'. By employing semiological interpretations of real landscapes from around the globe (for example, Venturi et al, 1972, The Strip becomes a newly invented landscape of "simulations" (Baudrillard, 1988. As such, The Strip acts as a narrative that forms a unique place, opening the door to questions of authenticity and identity. This paper concludes by focusing on the question of "Here or There?" as an appropriate deviation from the assumed role that the post-modern landscape of the Las Vegas Strip plays. This work is intended to be a point of departure from the frequent criticism of the Las Vegas Strip as

  10. Flexible Faraday Cage with a Twist: Surface Charge on a Mobius Strip

    Science.gov (United States)

    Stewart, Sean

    2007-01-01

    Once an intriguing topological novelty known only to mathematicians, the Mobius strip has become a source of fascination and inspiration to the layperson and artist alike. Principal among its features are the two strange properties that the Mobius strip is a surface with only one side and one edge. A Mobius strip is readily formed by taking a long…

  11. Towards an analytical theory for charged hard spheres

    Directory of Open Access Journals (Sweden)

    L.Blum

    2007-09-01

    Full Text Available Ion mixtures require an exclusion core to avoid collapse. The Debye Hueckel (DH theory, where ions are point charges, is accurate only in the limit of infinite dilution. The mean spherical approximation (MSA is the embedding of hard cores into DH, and is valid for higher densities. The properties of any ionic mixture can be represented by the single screening parameter Γ which for the equal ionic size restricted model is obtained from the Debye parameter κ. This Γ representation, the binding mean spherical approximation (BIMSA, is also valid for complex/associating systems, such as the general n-polyelectrolytes. The BIMSA is the only theory that satisfies the infinite dilution limit of the DH theory for any chain length. Furthermore, the contact pair distribution function calculated from our theory agrees with the Monte Carlo of Bresmeea. (Phys. Rev. E, 1995, 51, 289.

  12. Transfer printing of graphene strip from the graphene grown on copper wires

    International Nuclear Information System (INIS)

    Su, Ching-Yuan; Fu Dongliang; Lu, Ang-Yu; Liu, Keng-Ku; Xu Yanping; Juang, Zhen-Yu; Li, Lain-Jong

    2011-01-01

    A simple, cost-effective and lithography-free fabrication of graphene strips for device applications is demonstrated. The graphene thin layers were directly grown on Cu wires, followed by Cu etching and transfer printing to arbitrary substrates by a PDMS stamp. The Cu wires can be arranged on the PDMS stamp in a desired pattern; hence, the substrates can receive graphene strips with the same pattern. Moreover, the preparation of graphene strips does not involve conventional lithography; therefore, the surface of the graphene strip is free of residual photoresists, which may be useful for studies requiring clean graphene surfaces.

  13. Theoretical study of H- stripping with a wiggler magnet

    International Nuclear Information System (INIS)

    Hutson, R.L.

    1991-01-01

    The first step for injecting protons into the LAMPF Proton Storage Ring (PSR) at LANL is to strip a beam of 800-MeV H - ions to H 0 with a 1.8-T dipole magnet. Because of the finite lifetime of energetic H - ions in the magnetic field, their trajectories bend before stripping causing the angular spread of the beam, and therefore its emittance, to grow during the stripping process. In the case of the PSR, the horizontal beam emittance grows by a factor of roughly three during injection. As a consequence, beam losses in the ring are significantly greater than they would be if there were not emittance growth. A speculative technique is proposed in which the beam divergence growth and resulting emittance growth is reduced by stripping the H - in a wiggler magnet whose transverse field alternates in direction as a function of position along the beam axis. The wiggler field configuration is adjusted so that the angular beam spread introduced during passage through one unidirectional-field increment of path is relatively small and so that 99.99% of the beam is stripped after passing through the whole magnet. With careful field design the net added angular beam spread is reduced because the incremental angular spreads are painted back and forth over the same small range. In the hypothetical case described, the calculated emittance growth and beam loss increase are significantly smaller than those calculated for a conventional stripper magnet. 3 refs., 3 figs

  14. Communication Theoretic Data Analytics

    OpenAIRE

    Chen, Kwang-Cheng; Huang, Shao-Lun; Zheng, Lizhong; Poor, H. Vincent

    2015-01-01

    Widespread use of the Internet and social networks invokes the generation of big data, which is proving to be useful in a number of applications. To deal with explosively growing amounts of data, data analytics has emerged as a critical technology related to computing, signal processing, and information networking. In this paper, a formalism is considered in which data is modeled as a generalized social network and communication theory and information theory are thereby extended to data analy...

  15. Coordinate determination of high energy charged particles by silicon strip detectors

    International Nuclear Information System (INIS)

    Anokhin, I.E.; Zinets, O.S.

    2002-01-01

    The coordinate determination accuracy of minimum ionizing and short-range particles by silicon strip detectors has been considered. The charge collection on neighboring strips of the detector is studied and the influence of diffusion and the electric field distribution on the accuracy of the coordinate determination is analyzed. It has been shown that coordinates of both minimum ionizing and short-range particles can be determined with accuracy to a few microns using silicon strip detectors. 11 refs.; 8 figs

  16. Fabrication of silicon strip detectors using a step-and-repeat lithography system

    International Nuclear Information System (INIS)

    Holland, S.

    1991-11-01

    In this work we describe the use of a step-and-repeat lithography system (stepper) for the fabrication of silicon strip detectors. Although the field size of the stepper is only 20 mm in diameter, we have fabricated much larger detectors by printing a repetitive strip detector pattern in a step-and-repeat fashion. The basic unit cell is 7 mm in length. The stepper employs a laser interferometer for stage placement, and the resulting high precision allows one to accurately place the repetitive patterns on the wafer. A small overlap between the patterns ensures a continuous strip. A detector consisting of 512 strips on a 50 μm pitch has been fabricated using this technique. The dimensions of the detector are 6.3 cm by 2.56 cm. Yields of over 99% have been achieved, where yield is defined as the percentage of strips with reverse leakage current below 1 nA. In addition to the inherent advantages of a step-and-repeat system, this technique offers great flexibility in the fabrication of large-area strip detectors since the length and width of the detector can be changed by simply reprogramming the stepper computer. Hence various geometry strip detectors can be fabricated with only one set of masks, as opposed to a separate set of masks for each geometry as would be required with a contact or proximity aligner

  17. Moving strip technique of electron beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Kishio; Wakasa, Hiroyuki; Oguri, Nobuhiro; Kitayama, Takuichi; Nakagiri, Yoshitada; Mikami, Yasutaka; Hashimoto, Keiji; Hiraki, Yoshio; Aono, Kaname

    1984-12-01

    The fieldsize in electron beam therapy is determined by the cone size. In case of skin metastasis of a malignant tumor and so on, which need a large field size and whose area is much larger than the size of the cone, a large field size is usually produced by dividing the portals. However, the dose distribution at the border of the field becomes unequal, and hot and cold dose areas are produced according to the distance between portals. We tried the strip field technique in a large field along the long axis of the body in order to flatten the dose of the border employing the moving strip used for whole abdominal irradiation in ovarian cancer. We set the film in Mix-DP and used the strip field technique with 2.5cm steps. We discussed the relationship between the interval (distance between portals) and the flattening of the dose within the field. Skin movement due to breathing and influences on the flattening of the dose were considered. The proper flatness was obtained at depths of 0,1,2, and 3cm by setting the interval at 0.5cm. When skin movement was produced by breathing in +-1.5mm, the proper flaness was obtained also at a 0.5-cm interval. It seems that smoothing is increased by breathing. An ''electron beam moving strip'' with a 2.5-cm step and 0.5-cm interval was clinically effective in the treatment of patients with skin metastasis of colon cancer. (author).

  18. THz Wave Propagation on Strip Lines: Devices, Properties, and Applications

    Directory of Open Access Journals (Sweden)

    Y. Kadoya

    2008-06-01

    Full Text Available We report the propagation characteristics of THz pulses on micro-strip-lines and coplanar strip-lines, in which low permittivity polymer materials are used as the dielectric layer or the substrate. As a result of the low attenuation and small dispersion in the devices, the spectral width up to 3 THz can be achieved even after the 1 mm propagation. Spectroscopic characterizations of liquid or powder specimens are demonstrated using the devices. We also show a possibility of realizing a very low attenuation using a quadrupole mode in three strip coplanar lines on the polymer substrate.

  19. Improved dielectric functions in metallic films obtained via template stripping

    Science.gov (United States)

    Hyuk Park, Jong; Nagpal, Prashant; Oh, Sang-Hyun; Norris, David J.

    2012-02-01

    We compare the dielectric functions of silver interfaces obtained via thermal evaporation with those obtained with template stripping. Ellipsometry measurements show that the smoother template-stripped surfaces exhibit effective dielectric functions with a more negative real component and a smaller imaginary component, implying higher conductivity and less energy loss, respectively. These results agree with the relation between dielectric function and surface roughness derived from combining the effective-medium model and the Drude-Lorentz model. The improvement in the effective dielectric properties shows that metallic films prepared via template stripping can be favorable for applications in electronics, nanophotonics, and plasmonics.

  20. New technology for the production of magnesium strips and sheets

    Directory of Open Access Journals (Sweden)

    R. Kawalla

    2008-07-01

    Full Text Available A new production technology for magnesium strip, based on twin-roll-casting and strip rolling was developed in Freiberg Germany. By means of this economic method it is possible to produce strips in deep drawing quality with good forming properties in order to satisfy the request for low cost Mg sheets in the automotive and electronic industry. Both, coils as single sheets, were manufactured and rolled to a thickness of 1mm(0,5 mm. The technology of the new process and the properties of the twin-roll-casted material and the final sheets are presented.

  1. 3D silicon strip detectors

    International Nuclear Information System (INIS)

    Parzefall, Ulrich; Bates, Richard; Boscardin, Maurizio; Dalla Betta, Gian-Franco; Eckert, Simon; Eklund, Lars; Fleta, Celeste; Jakobs, Karl; Kuehn, Susanne; Lozano, Manuel; Pahn, Gregor; Parkes, Chris; Pellegrini, Giulio; Pennicard, David; Piemonte, Claudio; Ronchin, Sabina; Szumlak, Tomasz; Zoboli, Andrea; Zorzi, Nicola

    2009-01-01

    While the Large Hadron Collider (LHC) at CERN has started operation in autumn 2008, plans for a luminosity upgrade to the Super-LHC (sLHC) have already been developed for several years. This projected luminosity increase by an order of magnitude gives rise to a challenging radiation environment for tracking detectors at the LHC experiments. Significant improvements in radiation hardness are required with respect to the LHC. Using a strawman layout for the new tracker of the ATLAS experiment as an example, silicon strip detectors (SSDs) with short strips of 2-3 cm length are foreseen to cover the region from 28 to 60 cm distance to the beam. These SSD will be exposed to radiation levels up to 10 15 N eq /cm 2 , which makes radiation resistance a major concern for the upgraded ATLAS tracker. Several approaches to increasing the radiation hardness of silicon detectors exist. In this article, it is proposed to combine the radiation hard 3D-design originally conceived for pixel-style applications with the benefits of the established planar technology for strip detectors by using SSDs that have regularly spaced doped columns extending into the silicon bulk under the detector strips. The first 3D SSDs to become available for testing were made in the Single Type Column (STC) design, a technological simplification of the original 3D design. With such 3D SSDs, a small number of prototype sLHC detector modules with LHC-speed front-end electronics as used in the semiconductor tracking systems of present LHC experiments were built. Modules were tested before and after irradiation to fluences of 10 15 N eq /cm 2 . The tests were performed with three systems: a highly focused IR-laser with 5μm spot size to make position-resolved scans of the charge collection efficiency, an Sr 90 β-source set-up to measure the signal levels for a minimum ionizing particle (MIP), and a beam test with 180 GeV pions at CERN. This article gives a brief overview of the results obtained with 3D-STC-modules.

  2. 3D silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parzefall, Ulrich [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany)], E-mail: ulrich.parzefall@physik.uni-freiburg.de; Bates, Richard [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Boscardin, Maurizio [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Dalla Betta, Gian-Franco [INFN and Universita' di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Eckert, Simon [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Eklund, Lars; Fleta, Celeste [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Jakobs, Karl; Kuehn, Susanne [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Lozano, Manuel [Instituto de Microelectronica de Barcelona, IMB-CNM, CSIC, Barcelona (Spain); Pahn, Gregor [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Parkes, Chris [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Pellegrini, Giulio [Instituto de Microelectronica de Barcelona, IMB-CNM, CSIC, Barcelona (Spain); Pennicard, David [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Piemonte, Claudio; Ronchin, Sabina [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Szumlak, Tomasz [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Zoboli, Andrea [INFN and Universita' di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Zorzi, Nicola [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy)

    2009-06-01

    While the Large Hadron Collider (LHC) at CERN has started operation in autumn 2008, plans for a luminosity upgrade to the Super-LHC (sLHC) have already been developed for several years. This projected luminosity increase by an order of magnitude gives rise to a challenging radiation environment for tracking detectors at the LHC experiments. Significant improvements in radiation hardness are required with respect to the LHC. Using a strawman layout for the new tracker of the ATLAS experiment as an example, silicon strip detectors (SSDs) with short strips of 2-3 cm length are foreseen to cover the region from 28 to 60 cm distance to the beam. These SSD will be exposed to radiation levels up to 10{sup 15}N{sub eq}/cm{sup 2}, which makes radiation resistance a major concern for the upgraded ATLAS tracker. Several approaches to increasing the radiation hardness of silicon detectors exist. In this article, it is proposed to combine the radiation hard 3D-design originally conceived for pixel-style applications with the benefits of the established planar technology for strip detectors by using SSDs that have regularly spaced doped columns extending into the silicon bulk under the detector strips. The first 3D SSDs to become available for testing were made in the Single Type Column (STC) design, a technological simplification of the original 3D design. With such 3D SSDs, a small number of prototype sLHC detector modules with LHC-speed front-end electronics as used in the semiconductor tracking systems of present LHC experiments were built. Modules were tested before and after irradiation to fluences of 10{sup 15}N{sub eq}/cm{sup 2}. The tests were performed with three systems: a highly focused IR-laser with 5{mu}m spot size to make position-resolved scans of the charge collection efficiency, an Sr{sup 90}{beta}-source set-up to measure the signal levels for a minimum ionizing particle (MIP), and a beam test with 180 GeV pions at CERN. This article gives a brief overview of

  3. Bimetallic strip for low temperature use. [4-300/sup 0/K

    Science.gov (United States)

    Bussiee, J.F.; Welch, D.O.; Suenaga, M.

    A class of mechanically pre-stressed structures is provided suitably bi-layer strips, consisting of a layer of group 5 transition metals in intimate contact with a layer of an intermetallic compound of transition metals with certain group 3A, 4A or 5A metals or metalloids such as Ga, In, Si, Ge, Sn, As or Sb. The changes of Young's modulus of these bi-layered combinations at temperatures in the region of somewhat above absolute zero provides a useful means of sensing temperature changes. Such bi-metallic strips may be used as control strips in thermostats, or in direct dial reading instruments. The structures are made by preparing a sandwich of a group 5B transition metal strip between the substantially thicker strips of an alloy between copper and a predetermined group 3A, 4A or 5A metal or metalloid, holding the three layers are heated, cooled the copper alloys and is removed. Removing one of the two formed interlayer alloys between the transition metal and the metal previously alloyed with copper remain.

  4. Oxygen ordering in YBa2Cu3O6+x using Monte Carlo simulation and analytic theory

    DEFF Research Database (Denmark)

    Mønster, D.; Lindgård, Per-Anker; Andersen, N.H.

    2001-01-01

    We have simulated the phase diagram and structural properties of the oxygen ordering in YBa2Cu3O6+x testing simple extensions of the asymmetric next-nearest-neighbor Ising (ASYNNNI) Model. In a preliminary paper [Phys. Rev. B 60, 110 (1999)] we demonstrated that the inclusion of a single further...... on a nano scale into box-like domains and anti-domains of typical average dimension (10a,30b,2c). Theory and model simulations demonstrate that the distribution of such domains causes deviations from Lorentzian line shapes, and not the Porod effect. Analytic theory is used to estimate the effect of a range...... of values of the interaction parameters used, as well as the effect of an extension to include infinite ranged interactions. In the experiments a large cap is found between the onset temperatures of the ortho-I and ortho-II orders at x=0.5. This cannot be fully reproduced in the simulations. The simulations...

  5. Buffer Strips for Riparian Zone Management

    National Research Council Canada - National Science Library

    1991-01-01

    This study provides a review of technical literature concerning the width of riparian buffer strips needed to protect water quality and maintain other important values provided by riparian ecosystem...

  6. On the Formation of Ultra-Difuse Galaxies as Tidally-Stripped Systems

    Science.gov (United States)

    Carleton, Timothy; Cooper, Michael; Kaplinghat, Manoj; Errani, Raphael; Penarrubia, Jorge

    2018-01-01

    The recent identification of a large population of so-called 'Ultra-Diffuse' Galaxies (UDGs), with stellar masses ~108 M⊙, but half light radii over 1.5 kpc, has challenged our understanding of galaxy evolution. Motivated by the environmental dependence of UDG properties and abundance, I present a model for the formation of UDGs through tidal-stripping of dwarf galaxies in cored dark matter halos. To test this scenario, I utilize results from simulations of tidal stripping, which demonstrate that changes in the stellar profile of a tidally stripped galaxy can be written as a function of the amount of tidal stripping experienced by the halo (tidal tracks). These tracks, however, are different for cored and cuspy halos. Additional simulations show how the halo responds to tidal interactions given the halo orbit within a cluster.In particular, dwarf elliptical galaxies, born in 1010-10.5 M⊙ halos, expand significantly as a result of tidal stripping and produce UDGs. Applying these models to the population of halos in the Bolshoi simulation, I am able to follow the effects of tidal stripping on the dwarf galaxy population in clusters. Using tidal tracks for cuspy halos does not reproduce the observed properties of UDGs. However, using the tidal tracks for cored halos, I reproduce the distribution of sizes, stellar masses, and abundance of UDGs in clusters remarkably well.

  7. The Quality of Banking Services in Light of the Financial Transformations and Their Impact on the Marketing Performance of the Banks in Gaza Strip

    OpenAIRE

    Al Hila , Amal ,; Alhelou , Eitedal ,; Al Shobaki , Mazen ,; Abu Naser , Samy S

    2017-01-01

    International audience; This study aimed to investigate the effect on the quality of banking services marketing performance of banks operating in the Gaza Strip in light of the financial transitions from the perspective of employees, and the disclosure of the relationship between the quality of banking services and marketing performance from the perspective of employees and customers. The researcher used descriptive and analytical approach, and the study population of employees and customers ...

  8. Approaching total absorption of graphene strips using a c-Si subwavelength periodic membrane

    Science.gov (United States)

    Sang, Tian; Wang, Rui; Li, Junlang; Zhou, Jianyu; Wang, Yueke

    2018-04-01

    Approaching total absorption of graphene strips at near infrared using a crystalline-silicon (c-Si) subwavelength periodic membrane (SPM) is presented. The absorption in graphene strips in a c-Si SPM is enhanced by a resonant tip, which is resulted from the coupling between the guided mode and the radiation mode through symmetry breaking of the structure at near-normal incidence. The enhancement of the electric field intensity is increased 1939 times and the group velocity of light is decreased to 3.55 ×10-4c at resonance, and 99.3% absorption in graphene strips can be achieved by critical coupling at the incident angle of 2°. High absorption of the graphene strips can be maintained as the etching thickness, the strip width, and the period are altered. When this type of c-Si SPM with graphene strips is used in refractive index sensors, it shows excellent sensing properties due to its stable near-unity absorption.

  9. Ammonia removal from landfill leachate by air stripping and absorption.

    Science.gov (United States)

    Ferraz, Fernanda M; Povinelli, Jurandyr; Vieira, Eny Maria

    2013-01-01

    An old landfill leachate was pre-treated in a pilot-scale aerated packed tower operated in batch mode for total ammoniacal nitrogen (TAN) removal. The stripped ammonia was recovered with a 0.4 mol L(-1) H2SO4 solution, deionized water and tap water. Ca(OH)2 (95% purity) or commercial hydrated lime was added to the raw leachate to adjust its pH to 11, causing removal of colour (82%) and heavy metals (70-90% for Zn, Fe and Mn). The 0.4 molL(-1) H2SO4 solution was able to neutralize 80% of the stripped ammonia removed from 12 L of leachate. The effectiveness of the neutralization of ammonia with deionized water was 75%. Treating 100 L of leachate, the air stripping tower removed 88% of TAN after 72 h of aeration, and 87% of the stripped ammonia was recovered in two 31 L pilot-scale absorption units filled with 20 L of tap water.

  10. The New Silicon Strip Detectors for the CMS Tracker Upgrade

    CERN Document Server

    Dragicevic, Marko

    2010-01-01

    The first introductory part of the thesis describes the concept of the CMS experiment. The tasks of the various detector systems and their technical implementations in CMS are explained. To facilitate the understanding of the basic principles of silicon strip sensors, the subsequent chapter discusses the fundamentals in semiconductor technology, with particular emphasis on silicon. The necessary process steps to manufacture strip sensors in a so-called planar process are described in detail. Furthermore, the effects of irradiation on silicon strip sensors are discussed. To conclude the introductory part of the thesis, the design of the silicon strip sensors of the CMS Tracker are described in detail. The choice of the substrate material and the complex geometry of the sensors are reviewed and the quality assurance procedures for the production of the sensors are presented. Furthermore the design of the detector modules are described. The main part of this thesis starts with a discussion on the demands on the ...

  11. Kirchhoff plate theory-based electromechanically-coupled analytical model considering inertia and stiffness effects of a surface-bonded piezoelectric patch

    International Nuclear Information System (INIS)

    Yoon, Heonjun; Youn, Byeng D; Kim, Heung Soo

    2016-01-01

    As a compact and durable design concept, piezoelectric energy harvesting skin (PEH skin) has been recently proposed for self-powered electronic device applications. This study aims to develop an electromechanically-coupled analytical model of PEH skin considering the inertia and stiffness effects of a piezoelectric patch. Based on Kirchhoff plate theory, Hamilton’s principle is used to derive the electromechanically-coupled differential equation of motion. Due to the geometric discontinuity of the piezoelectric patch, the Rayleigh–Ritz method is applied to calculate the natural frequency and corresponding mode shapes. The electrical circuit equation is derived from Gauss’s law. Output voltage is estimated by solving the equation of motion and electrical circuit equation, simultaneously. For the purpose of evaluating the predictive capability, the results of the electromechanically-coupled analytical model are compared with those of the finite element method in a hierarchical manner. The outstanding merits of the electromechanically-coupled analytical model of PEH skin are three-fold: (1) consideration of the inertia and stiffness effects of the piezoelectric patches; (2) physical parameterization between the two-dimensional mechanical configuration and piezoelectric transduction; (3) manipulability of the twisting modes of a cantilever plate with a small aspect ratio. (paper)

  12. Engineering test of stripping performance by multi-centrifugal contactors system for spent nuclear reprocessing

    International Nuclear Information System (INIS)

    Masayuki Takeuchi; Tadahiro Washiya; Hiroki Nakabayashi; Takashi Suganuma; Shinnichi Aose

    2005-01-01

    Japan Nuclear Cycle Development Institute (JNC) has been developing centrifugal contactors which are compact and high performance for solvent extraction process in industrial reprocessing plant. The stripping performance including equilibrium time for distribution and hydraulic behavior of the multi-centrifugal contactors were mainly evaluated by using uranium nitrite solution on engineering scale (10 kgHM/hr). In particular, the effects of feed temperature of stripping solution and O/A on the stripping performance were focused in this test. As results, no hydraulic problem such as overflow and entrainment were observed in multi-centrifugal contactors system through all conditions, and the uranium and acid concentrations showed desirable profiles which were nearly consistent with calculated one by MIXSET-X code. As to stripping performance, uranium leak concentration in solvent reached to less than 0.01 g/L, which is target of the stripping performance on this centrifugal contactors system, within nine stages on all conditions. It was also found that the effect of feed temperature of stripping solution (35 degree C → 60 degree C) or O/A (1.0→0.8) on stripping performance corresponds to distribution capacity of two contactors, respectively. The stage efficiency for a contactor was estimated as 97-98% on stripping stage. There were no uranium leaks (less than 40μg/L) in spent solvent discharged from the final stage. The profiles of uranium concentration in multi-contactors become stable within 10 minutes after the stripping test starting. In this way, it was demonstrated that the centrifugal contactors system has good stripping performance on engineering scale. (authors)

  13. Adsorptive stripping voltammetric methods for determination of aripiprazole

    Directory of Open Access Journals (Sweden)

    Derya Aşangil

    2012-06-01

    Full Text Available Anodic behavior of aripiprazole (ARP was studied using electrochemical methods. Charge transfer, diffusion and surface coverage coefficients of adsorbed molecules and the number of electrons transferred in electrode mechanisms were calculated for quasi-reversible and adsorption-controlled electrochemical oxidation of ARP at 1.15 V versus Ag/AgCl at pH 4.0 in Britton–Robinson buffer (BR on glassy carbon electrode. Voltammetric methods for direct determination of ARP in pharmaceutical dosage forms and biological samples were developed. Linearity range is found as from 11.4 μM (5.11 mg/L to 157 μM (70.41 mg/L without stripping mode and it is found as from 0.221 μM (0.10 mg/L to 13.6 μM (6.10 mg/L with stripping mode. Limit of detection (LOD was found to be 0.11 μM (0.05 mg/L in stripping voltammetry. Methods were successfully applied to assay the drug in tablets, human serum and human urine with good recoveries between 95.0% and 104.6% with relative standard deviation less than 10%. Keywords: Adsorptive stripping voltammetry, Aripiprazole, Electrochemical behavior, Human serum and urine, Pharmaceuticals

  14. Strip-till seeder for sugar beets

    Directory of Open Access Journals (Sweden)

    Peter Schulze Lammers

    2014-06-01

    Full Text Available Strip-till save costs by reducing tillage on the area of sugar beet rows only. The seeding system is characterized by a deep loosening of soil with a tine combined with a share and by following tools generating fine-grained soil as seed bed. In cooperation with the Kverneland company group Soest/Germany a strip tiller combined with precision seeder was designed and tested in field experiments. Tilling and seeding was performed in one path on fields with straw and mustard mulch. Even the plant development was slower as compared to conventional sawn sugar beets the yield was on equivalent level. Further field experiments are planned to attest constant yield, cost and energy efficiency of the seeding system.

  15. Synchrotron applications of pixel and strip detectors at Diamond Light Source

    International Nuclear Information System (INIS)

    Marchal, J.; Tartoni, N.; Nave, C.

    2009-01-01

    A wide range of position-sensitive X-ray detectors have been commissioned on the synchrotron X-ray beamlines operating at the Diamond Light Source in UK. In addition to mature technologies such as image-plates, CCD-based detectors, multi-wire and micro-strip gas detectors, more recent detectors based on semiconductor pixel or strip sensors coupled to CMOS read-out chips are also in use for routine synchrotron X-ray diffraction and scattering experiments. The performance of several commercial and developmental pixel/strip detectors for synchrotron studies are discussed with emphasis on the image quality achieved with these devices. Examples of pixel or strip detector applications at Diamond Light Source as well as the status of the commissioning of these detectors on the beamlines are presented. Finally, priorities and ideas for future developments are discussed.

  16. Neuroprotective effect of Zhen Tian Wan on pial strip-induced ...

    African Journals Online (AJOL)

    ZTW significantly reduced the level of free radicals in pial stripped rats. ZTW can improve learning and memory function and it possess anti-oxidant activity. ZTW may be beneficial in the treatment of vascular dementia. Keywords: Zhen Tian Wan; pial strip; lesion; Memory; Morris water maze; free radicals ...

  17. Scaling of ammonia stripping towers in the treatment of groundwater polluted by municipal solid waste landfill leachate: study of the causes of scaling and its effects on stripping performance

    Directory of Open Access Journals (Sweden)

    Paolo Viotti

    2015-04-01

    Full Text Available This paper documents the causes of the scaling of stripping towers used for the treatment of groundwater polluted by the leachate from an old municipal solid waste (MSW landfill in northern Italy. The effects of the scaling on the stripping performance are also reported. The whole process consists of a coagulation-flocculation pre-treatment at pH > 11, followed by an ammonia stripping stage, after heating the water to 38°C in order to improve removal efficiency. The stripped ammonia is recovered by absorption with sulfuric acid, producing a 30% solution of ammonium sulfate (reused as a base fertilizer. The effluent air stream is recirculated to the stripping towers (closed loop systems in order to avoid an excessive temperature drop inside the packings, mainly in winter, with consequent loss of efficiency and risk of icing. The progressive scaling of the packing has resulted in a loss of ammonia removal efficiency from an initial value of 98% (clean packing down to 80% after six months of continuous operation, necessitating a chemical cleaning. Optimum conditions for design and operation of the stripping process are also documented.

  18. An analysis of stripping to isolated analog resonances

    International Nuclear Information System (INIS)

    Pessoa, E.F.; Toledo Piza, A.F.R. de.

    1983-04-01

    The Feshbach projection formalism is used to calculate the form factors for the (d,n) stripping process to isolated analog resonances. These are used in a standard DWBA stripping calculation in which the radial integration over all space is accomplished by including outerspace contributions evaluated along the complex contours of Vincent and Fortune. It turns out that the shape and magnitude of the predicted cross section is quite insensitive to the continuum proton wave emanating from the resonant residual state. (Author) [pt

  19. Study of surface properties of ATLAS12 strip sensors and their radiation resistance

    Energy Technology Data Exchange (ETDEWEB)

    Mikestikova, M., E-mail: mikestik@fzu.cz [Academy of Sciences of the Czech Republic, Institute of Physics, Na Slovance 2, 18221 Prague 8 (Czech Republic); Allport, P.P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J.P.; Wilson, J.A. [School of Physics and Astronomy, University of Birmingham, Birmingham B15 2TT (United Kingdom); Kierstead, J.; Kuczewski, P.; Lynn, D. [Brookhaven National Laboratory, Physics Department and Instrumentation Division, Upton, NY 11973-5000 (United States); Hommels, L.B.A. [Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Ullan, M. [Centro Nacional de Microelectronica (IMB-CNM, CSIC), Campus UAB-Bellaterra, 08193 Barcelona (Spain); Bloch, I.; Gregor, I.M.; Tackmann, K. [DESY, Notkestrasse 85, 22607 Hamburg (Germany); Hauser, M.; Jakobs, K.; Kuehn, S. [Physikalisches Institut, Universität Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); and others

    2016-09-21

    A radiation hard n{sup +}-in-p micro-strip sensor for the use in the Upgrade of the strip tracker of the ATLAS experiment at the High Luminosity Large Hadron Collider (HL-LHC) has been developed by the “ATLAS ITk Strip Sensor collaboration” and produced by Hamamatsu Photonics. Surface properties of different types of end-cap and barrel miniature sensors of the latest sensor design ATLAS12 have been studied before and after irradiation. The tested barrel sensors vary in “punch-through protection” (PTP) structure, and the end-cap sensors, whose stereo-strips differ in fan geometry, in strip pitch and in edge strip ganging options. Sensors have been irradiated with proton fluences of up to 1×10{sup 16} n{sub eq}/cm{sup 2}, by reactor neutron fluence of 1×10{sup 15} n{sub eq}/cm{sup 2} and by gamma rays from {sup 60}Co up to dose of 1 MGy. The main goal of the present study is to characterize the leakage current for micro-discharge breakdown voltage estimation, the inter-strip resistance and capacitance, the bias resistance and the effectiveness of PTP structures as a function of bias voltage and fluence. It has been verified that the ATLAS12 sensors have high breakdown voltage well above the operational voltage which implies that different geometries of sensors do not influence their stability. The inter-strip isolation is a strong function of irradiation fluence, however the sensor performance is acceptable in the expected range for HL-LHC. New gated PTP structure exhibits low PTP onset voltage and sharp cut-off of effective resistance even at the highest tested radiation fluence. The inter-strip capacitance complies with the technical specification required before irradiation and no radiation-induced degradation was observed. A summary of ATLAS12 sensors tests is presented including a comparison of results from different irradiation sites. The measured characteristics are compared with the previous prototype of the sensor design, ATLAS07. - Highlights:

  20. AIS/DOE Technology Roadmap Program: Strip Casting: Anticipating New Routes To Steel Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Prof. Alan W. Camb; Prof. Anthony Rollett

    2001-08-31

    To determine the potential for strip casting in the steel industry and to develop the fundamental knowledge necessary to allow the role of strip casting in the modern steel industry to be understood. Based upon a study of carbon steel strip castings that were either produced for the program at British Steel or were received from a pre-commercial production machine, the following conclusions were made. Strip casting of carbon steels is technically feasible for sheet material from slightly less than 1 mm thick to 3 mm thick, and, assuming that it is economically viable, it will be first applied in carbon steel markets that do not require stringent surface quality or extensive forming. The potential of strip casting as a casting process to be developed for steel castings is very high as the cast strip has some very novel characteristics. Direct cast carbon strip has better surface quality, shape and profile than any other casting process currently available. The more rapidly solidified structure of direct cast strip tends to be strong with low ductility; however, with adequate thermal treatment, it is possible to develop a variety of properties from the same grade. The process is more amenable at this time to production tonnages per year of the order of 500,000 tons and as such will first find niche type applications. This technology is an additional technology for steel production and will be in addition to, rather than a replacement for, current casting machines.

  1. Effect of stimulation intensity and botulinum toxin isoform on rat bladder strip contractions.

    Science.gov (United States)

    Smith, Christopher P; Boone, Timothy B; de Groat, William C; Chancellor, Michael B; Somogyi, George T

    2003-07-15

    The present experiments compared the inhibitory effects of botulinum toxin A (BoNT-A) and botulinum toxin D (BoNT-D) on neurally evoked contractions of rat bladder strips. We examined the effect of fatigue (trains of 100 shocks at 20Hz every 20s for 10min) followed by non-fatigue stimulation (trains of 100 shocks at 20Hz every 100s for 20min) on the onset of effect and potency of the two toxins. For non-fatigue experiments, strips were untreated (n=4); or incubated with 1.36nM BoNT-A (n=4). During fatigue experiments, strips were untreated (n=5); or treated with either 1.36nM BoNT-A (n=6) or 0.8nM BoNT-D (n=6). In non-fatigue experiments, BoNT-A produced significant decreases in contractile area after 1h of stimulation compared to untreated strips (PD bladder strips, were statistically significant (PD-treated strips, as a significant reduction (PD) and untreated bladder strips responded similarly to atropine, suggesting that the effects of BoNT result from inhibition of both acetylcholine and ATP release. Our results demonstrate that BoNT-D may be a more effective agent to inhibit transmitter release from autonomic nerves of the rat lower urinary tract. Moreover, in our hands, non-fatigue stimulation is as effective as fatigue stimulation in inhibiting bladder strip contractions.

  2. Analytical Thermal Field Theory Applicable to Oil Hydraulic Fluid Film Lubrication

    DEFF Research Database (Denmark)

    Johansen, Per; Roemer, Daniel Beck; Pedersen, Henrik C.

    2014-01-01

    the analytical approach provides an alternative to existing computationally expensive numerical methods. The paper presents the dimensional analysis, which provides the foundation for the derivation of the analytical approximation. Subsequently, the perturbation method is applied in order to find an asymptotic...

  3. Silicon Strip Detectors for ATLAS at the HL-LHC Upgrade

    CERN Document Server

    Hara, K; The ATLAS collaboration

    2012-01-01

    present ATLAS silicon strip tracker (SCT) and transition radiation tracker(TRT) are to be replaced with new silicon strip detectors as part of the Inner Tracker System (ITK) for the Phase-II upgrade of the Large Hadron Collider, HL-LHC. We have carried out intensive R&D programs based on n+-on-p microstrip detectors to fabricate improved radiation hard strip detectors that can survive the radiation levels corresponding to the integrated luminosity of up to 3000 fb−1. We describe the main specifications for this year’s sensor fabrication and the related R&D results, followed by a description of the candidate schema for module integration.

  4. Three-body model of deuteron breakup and stripping, II

    International Nuclear Information System (INIS)

    Austern, N.; Vincent, C.M.; Farrell, J.P. Jr.

    1978-01-01

    A previously investigated three-body model of the deuteron-nucleus system, limited to relative angular momentum l=0 for the two active nucleons, is reevaluated. Full attention is given to self-consistency between elastic and breakup channels. Introduction of the reaction of breakup on the elastic channel now reduces the elastic reflection coefficients in low partial waves by nearly a factor of 2 and causes substantial shifts in phase. Breakup amplitudes in low partial waves are also greatly reduced. As before, the breakup part of the wavefunction contains a broad specteum of n-p continuum states. The breakup part of the wavefunction at zero n-p separation is localized at small radii, within and just outside the target nucleus, where it is comparable in magnitude with the projected elastic channel wavefunction. As a result, the projected elastic channel wavefuntion is a poor approximation to the full wavefunction at n-p coincidence. Deuteron stripping theories that use the projected elastic wavefunction in a truncated distorted waves Born series must correspondingly be quite misleading. To investigate deuteron stripping further, the exact result of the coupled channels calculation is compared with several standard approximate models. Although there is a close qualitative resemblance among the results of all the approaches, the best single approximation to the coupled channels result is found from the familiar phenomenological approach, in which a local optical potential is fitted to the elastic scattering ''observed'' in the coupled channels calculation. The coupled channels results are also used to analyze the approximations in the Johnson-Soper method. Several formal aspects of the three-body model are discussed

  5. Distillation and Air Stripping Designs for the Lunar Surface

    Science.gov (United States)

    Boul, Peter J.; Lange, Kevin E.; Conger, Bruce; Anderson, Molly

    2009-01-01

    Air stripping and distillation are two different gravity-based methods, which may be applied to the purification of wastewater on the lunar base. These gravity-based solutions to water processing are robust physical separation techniques, which may be advantageous to many other techniques for their simplicity in design and operation. The two techniques can be used in conjunction with each other to obtain high purity water. The components and feed compositions for modeling waste water streams are presented in conjunction with the Aspen property system for traditional stage distillation models and air stripping models. While the individual components for each of the waste streams will vary naturally within certain bounds, an analog model for waste water processing is suggested based on typical concentration ranges for these components. Target purity levels for the for recycled water are determined for each individual component based on NASA s required maximum contaminant levels for potable water Distillation processes are modeled separately and in tandem with air stripping to demonstrate the potential effectiveness and utility of these methods in recycling wastewater on the Moon. Optimum parameters such as reflux ratio, feed stage location, and processing rates are determined with respect to the power consumption of the process. Multistage distillation is evaluated for components in wastewater to determine the minimum number of stages necessary for each of 65 components in humidity condensate and urine wastewater mixed streams. Components of the wastewater streams are ranked by Henry s Law Constant and the suitability of air stripping in the purification of wastewater in terms of component removal is evaluated. Scaling factors for distillation and air stripping columns are presented to account for the difference in the lunar gravitation environment. Commercially available distillation and air stripping units which are considered suitable for Exploration Life Support

  6. Simulation studies for the ATLAS upgrade Strip tracker

    CERN Document Server

    Wang, Jike; The ATLAS collaboration

    2017-01-01

    ATLAS is making extensive efforts towards preparing a detector upgrade for the High luminosity operations of the LHC (HL-LHC), which will commence operation in ~10 years. The current ATLAS Inner Detector will be replaced by a all-silicon tracker (comprising an inner Pixel tracker and outer Strip tracker). The software currently used for the new silicon tracker is broadly inherited from that used for the LHC Run 1 and 2, but many new developments have been made to better fulfil the future detector and operation requirements. One aspect in particular which will be highlighted is the simulation software for the Strip tracker. The available geometry description software (including the detailed description for all the sensitive elements, the services, etc.) did not allow for accurate modeling of the planned detector design. A range of sensors/layouts for the Strip tracker are being considered and must be studied in detailed simulations in order to assess the performance and ascertain that requirements are met. For...

  7. GAS DEPLETION IN LOCAL GROUP DWARFS ON ∼250 kpc SCALES: RAM PRESSURE STRIPPING ASSISTED BY INTERNAL HEATING AT EARLY TIMES

    International Nuclear Information System (INIS)

    Nichols, Matthew; Bland-Hawthorn, Joss

    2011-01-01

    A recent survey of the Galaxy and M31 reveals that more than 90% of dwarf galaxies within 270 kpc of their host galaxy are deficient in H I gas. At such an extreme radius, the coronal halo gas is an order of magnitude too low to remove H I gas through ram pressure stripping for any reasonable orbit distribution. However, all dwarfs are known to have an ancient stellar population (∼> 10 Gyr) from early epochs of vigorous star formation which, through heating of H I, could allow the hot halo to remove this gas. Our model looks at the evolution of these dwarf galaxies analytically as the host-galaxy dark matter halo and coronal halo gas build up over cosmic time. The dwarf galaxies-treated as spherically symmetric, smooth distributions of dark matter and gas-experience early star formation, which sufficiently heats the gas, allowing it to be removed easily through tidal stripping by the host galaxy, or ram pressure stripping by a tenuous hot halo (n H = 3 x 10 -4 cm -3 at 50 kpc). This model of evolution is able to explain the observed radial distribution of gas-deficient and gas-rich dwarfs around the Galaxy and M31 if the dwarfs fell in at high redshift (z ∼ 3-10).

  8. Modi ed strip packing heuristics for the rectangular variable-sized ...

    African Journals Online (AJOL)

    Two packing problems are considered in this paper, namely the well-known strip packing problem (SPP) and the variable-sized bin packing problem (VSBPP). A total of 252 strip packing heuristics (and variations thereof) from the literature, as well as novel heuristics proposed by the authors, are compared statistically by ...

  9. A fluorescent immunochromatographic strip test using Quantum Dots for fumonisins detection.

    Science.gov (United States)

    Di Nardo, F; Anfossi, L; Giovannoli, C; Passini, C; Goftman, V V; Goryacheva, I Y; Baggiani, C

    2016-04-01

    A fluorescent immunochromatographic strip test (ICST) based on the use of Quantum Dots (QD) was developed and applied to detect fumonisins in maize samples. A limit of detection for fumonisin B1 of 2.8 µg L(-1) was achieved, with an analytical working range of 3-350 µg L(-1), corresponding to 30-3500 µg kg(-1) in maize flour samples, according with the extraction procedure. The time required to perform the analysis was 22 min, including sample preparation. Recovery values in the range from 91.4% to 105.4% with coefficients of variation not exceeding 5% were obtained for fortified and naturally contaminated maize flour samples. To evaluate the possible improvements due to the use of QD for ICST technology, we performed a direct comparison of the proposed QD-ICST to a gold nanoparticles- and a chemiluminescent-ICST previously developed for fumonisins detection, in which the same immunoreagents were employed. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Nuclear reactor spring strip grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Flora, B.S.

    1980-01-01

    An improved and novel grid spacer was developed for use in nuclear reactor fuel assemblies. It is comprised of a series of intersecting support strips and a peripheral support band attached to the ends of the support strips. Each of the openings into which the fuel element is inserted has a number of protruding dimples and springs extending in different directions. The dimples coact with the springs to secure the fuel rods in the openings. Compared with previous designs, this design gives more positive alignment of the support stips while allowing greater flexibility to counterbalance the effects of thermal expansion. The springs are arranged in alternating directions so that the reaction forces tend to counterbalance each other, which in turn minimizes the reaction loads on the supporting structure. (D.N.)

  11. Analytic description of the frictionally engaged in-plane bending process incremental swivel bending (ISB)

    Science.gov (United States)

    Frohn, Peter; Engel, Bernd; Groth, Sebastian

    2018-05-01

    Kinematic forming processes shape geometries by the process parameters to achieve a more universal process utilizations regarding geometric configurations. The kinematic forming process Incremental Swivel Bending (ISB) bends sheet metal strips or profiles in plane. The sequence for bending an arc increment is composed of the steps clamping, bending, force release and feed. The bending moment is frictionally engaged by two clamping units in a laterally adjustable bending pivot. A minimum clamping force hindering the material from slipping through the clamping units is a crucial criterion to achieve a well-defined incremental arc. Therefore, an analytic description of a singular bent increment is developed in this paper. The bending moment is calculated by the uniaxial stress distribution over the profiles' width depending on the bending pivot's position. By a Coulomb' based friction model, necessary clamping force is described in dependence of friction, offset, dimensions of the clamping tools and strip thickness as well as material parameters. Boundaries for the uniaxial stress calculation are given in dependence of friction, tools' dimensions and strip thickness. The results indicate that changing the bending pivot to an eccentric position significantly affects the process' bending moment and, hence, clamping force, which is given in dependence of yield stress and hardening exponent. FE simulations validate the model with satisfactory accordance.

  12. ALICE Silicon Strip Detector

    CERN Multimedia

    Nooren, G

    2013-01-01

    The Silicon Strip Detector (SSD) constitutes the two outermost layers of the Inner Tracking System (ITS) of the ALICE Experiment. The SSD plays a crucial role in the tracking of the particles produced in the collisions connecting the tracks from the external detectors (Time Projection Chamber) to the ITS. The SSD also contributes to the particle identification through the measurement of their energy loss.

  13. Distribution of electric field and charge collection in silicon strip detectors

    International Nuclear Information System (INIS)

    Anokhin, I.E.; Zinets, O.S.

    1995-01-01

    The distribution of electric field in silicon strip detectors is analyzed in the case of dull depletion as well as for partial depletion. Influence of inhomogeneous electric fields on the charge collection and performances of silicon strip detectors is discussed

  14. Experimental evidence that wildflower strips increase pollinator visits to crops.

    Science.gov (United States)

    Feltham, Hannah; Park, Kirsty; Minderman, Jeroen; Goulson, Dave

    2015-08-01

    Wild bees provide a free and potentially diverse ecosystem service to farmers growing pollination-dependent crops. While many crops benefit from insect pollination, soft fruit crops, including strawberries are highly dependent on this ecosystem service to produce viable fruit. However, as a result of intensive farming practices and declining pollinator populations, farmers are increasingly turning to commercially reared bees to ensure that crops are adequately pollinated throughout the season. Wildflower strips are a commonly used measure aimed at the conservation of wild pollinators. It has been suggested that commercial crops may also benefit from the presence of noncrop flowers; however, the efficacy and economic benefits of sowing flower strips for crops remain relatively unstudied. In a study system that utilizes both wild and commercial pollinators, we test whether wildflower strips increase the number of visits to adjacent commercial strawberry crops by pollinating insects. We quantified this by experimentally sowing wildflower strips approximately 20 meters away from the crop and recording the number of pollinator visits to crops with, and without, flower strips. Between June and August 2013, we walked 292 crop transects at six farms in Scotland, recording a total of 2826 pollinators. On average, the frequency of pollinator visits was 25% higher for crops with adjacent flower strips compared to those without, with a combination of wild and commercial bumblebees (Bombus spp.) accounting for 67% of all pollinators observed. This effect was independent of other confounding effects, such as the number of flowers on the crop, date, and temperature. Synthesis and applications. This study provides evidence that soft fruit farmers can increase the number of pollinators that visit their crops by sowing inexpensive flower seed mixes nearby. By investing in this management option, farmers have the potential to increase and sustain pollinator populations over time.

  15. Use of hydrogen peroxide to achieve interference-free stripping voltammetric determination of copper at the bismuth-film electrode

    International Nuclear Information System (INIS)

    Pacheco, Wagner F.; Miguel, Eliane M.; Ramos, Gabriel V.; Cardoso, Carlos E.; Farias, Percio A.M.; Aucelio, Ricardo Q.

    2008-01-01

    In this work, a new approach is presented to allow interference-free determination of Cu (II) by stripping voltammetry using the bismuth-film electrode. The addition of hydrogen peroxide to the electroanalytical cell has promoted complete resolution between re-dissolution peaks of Bi (III) and Cu (II). The absence of interference could be evaluated by the correlation coefficient (r > 0.99) between Cu (II) concentration and its shifted current peak (at +212 mV) while achieving a slightly fluctuation of the bismuth current peak at -180 mV. Studies were performed aiming towards the optimum conditions for trace determination of Cu (II) using hydrogen peroxide. The methodology was applied to a real sample (sugarcane spirits) and the results were compared to those from graphite furnace atomic absorption spectrometry. The analytical parameters of merit and the results of the analysis indicated that the analytical methodology could be readily used for trace determination of Cu (II)

  16. Advancements of floating strip Micromegas detectors for medical imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Klitzner, Felix; Biebel, Otmar; Bortfeldt, Jonathan; Flierl, Bernhard [LS Schaile, LMU Muenchen (Germany); Magallanes, Lorena [LS Parodi, LMU Muenchen (Germany); Universitaetsklinikum Heidelberg (Germany); Parodi, Katia [LS Parodi, LMU Muenchen (Germany); Heidelberger Ionenstrahl Therapiezentrum (Germany); Voss, Bernd [Gesellschaft fuer Schwerionenforschung, Darmstadt (Germany)

    2016-07-01

    Floating strip Micromegas have proven to be high-rate capable tracking detectors with excellent spatial and temporal resolution for particle fluxes up to 7 MHz/cm{sup 2}. To further increase the high-rate capability a Ne:CF{sub 4} 86:14 vol.% gas mixture has been used as detector gas. We present results from measurements with a seven detector system consisting of six low material budget floating strip Micromegas, a GEM detector and a scintillator based particle range telescope. The gaseous and the scintillation detectors were read out with APV25 frontend boards, allowing for single strip readout with pulse height and timing information. A two-dimensional readout anode for floating strip Micromegas has been tested for the first time. The Micromegas detectors were operated with minimal additional drift field, which significantly improves the timing resolution and also the spatial resolution for inclined tracks. We discuss the detector performance in high-rate carbon and proton beams at the Heidelberg Ion Beam Therapy Center (HIT) and present radiographies of phantoms, acquired with the system.

  17. MUST: A silicon strip detector array for radioactive beam experiments

    CERN Document Server

    Blumenfeld, Y; Sauvestre, J E; Maréchal, F; Ottini, S; Alamanos, N; Barbier, A; Beaumel, D; Bonnereau, B; Charlet, D; Clavelin, J F; Courtat, P; Delbourgo-Salvador, P; Douet, R; Engrand, M; Ethvignot, T; Gillibert, A; Khan, E; Lapoux, V; Lagoyannis, A; Lavergne, L; Lebon, S; Lelong, P; Lesage, A; Le Ven, V; Lhenry, I; Martin, J M; Musumarra, A; Pita, S; Petizon, L; Pollacco, E; Pouthas, J; Richard, A; Rougier, D; Santonocito, D; Scarpaci, J A; Sida, J L; Soulet, C; Stutzmann, J S; Suomijärvi, T; Szmigiel, M; Volkov, P; Voltolini, G

    1999-01-01

    A new and innovative array, MUST, based on silicon strip technology and dedicated to the study of reactions induced by radioactive beams on light particles is described. The detector consists of 8 silicon strip - Si(Li) telescopes used to identify recoiling light charged particles through time of flight, energy loss and energy measurements and to determine precisely their scattering angle through X, Y position measurements. Each 60x60 mm sup 2 double sided silicon strip detector with 60 vertical and 60 horizontal strips yields an X-Y position resolution of 1 mm, an energy resolution of 50 keV, a time resolution of around 1 ns and a 500 keV energy threshold for protons. The backing Si(Li) detectors stop protons up to 25 MeV with a resolution of approximately 50 keV. CsI crystals read out by photo-diodes which stop protons up to 70 MeV are added to the telescopes for applications where higher energy particles need to be detected. The dedicated electronics in VXIbus standard allow us to house the 968 logic and a...

  18. Deposits from Creams Containing 20% (w/w) Urea and Suppression of Crystallization (Part 2): Novel Analytical Methods of Urea Accumulated in the Stratum Corneum by Tape stripping and Colorimetry.

    Science.gov (United States)

    Goto, Norio; Morita, Yutaka; Terada, Katsuhide

    2016-01-01

    The transfer of urea from a urea formulation to the stratum corneum varies with the formulation base and form, and impacts the formulation's therapeutic effect. Consequently, determining the amount of urea transferred is essential for developing efficient formulations. This study assessed a simple method for measuring the amount of urea accumulated in the stratum corneum. Conventional methods rely on labeling urea used in the formulation with radiocarbon ((14)C) or other radioactive isotopes (RIs), retrieving the transferred urea from the stratum corneum by tape stripping, then quantitating the urea. The handling and use of RIs, however, is subject to legal regulation and can only be performed in sanctioned facilities, so methods employing RIs are neither simple nor convenient. We therefore developed a non-radiolabel method "tape stripping-colorimetry (T-C)" that combines tape stripping with colorimetry (urease-glutamate dehydrogenase (GLDH)) for the quantitative measurement of urea. Urea in the stratum corneum is collected by tape stripping and measured using urease-GLDH, which is commonly used to measure urea nitrogen in blood tests. The results indicate that accurate urea measurement by the T-C method requires the application of 1400 mg (on hairless rats) of a 20% urea solution on a 50 cm(2) (5×10 cm) area. Further, we determined the amount of urea accumulated in the stratum corneum using formulations with different urea concentrations, and the time course of urea accumulation from formulations differing in the rate of urea crystallization. We demonstrate that the T-C method is simple and convenient, with no need for (14)C or other RIs.

  19. Bell inequality, nonlocality and analyticity

    International Nuclear Information System (INIS)

    Socolovsky, M.

    2003-01-01

    The Bell and the Clauser-Horne-Shimony-Holt inequalities are shown to hold for both the cases of complex and real analytic nonlocality in the setting parameters of Einstein-Podolsky-Rosen-Bohm experiments for spin ((1)/(2)) particles and photons, in both the deterministic and stochastic cases. Therefore, the theoretical and experimental violation of the inequalities by quantum mechanics excludes all hidden variables theories with that kind of nonlocality. In particular, real analyticity leads to negative definite correlations, in contradiction with quantum mechanics

  20. Bell inequality, nonlocality and analyticity

    Energy Technology Data Exchange (ETDEWEB)

    Socolovsky, M

    2003-09-15

    The Bell and the Clauser-Horne-Shimony-Holt inequalities are shown to hold for both the cases of complex and real analytic nonlocality in the setting parameters of Einstein-Podolsky-Rosen-Bohm experiments for spin ((1)/(2)) particles and photons, in both the deterministic and stochastic cases. Therefore, the theoretical and experimental violation of the inequalities by quantum mechanics excludes all hidden variables theories with that kind of nonlocality. In particular, real analyticity leads to negative definite correlations, in contradiction with quantum mechanics.

  1. Evaluation of FOXFET biased ac-coupled silicon strip detector prototypes for CDF SVX upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Laakso, M. (Fermi National Accelerator Lab., Batavia, IL (United States) Research Inst. for High Energy Physics (SEFT), Helsinki (Finland))

    1992-03-01

    Silicon microstrip detectors for high-precision charged particle position measurements have been used in nuclear and particle physics for years. The detectors have evolved from simple surface barrier strip detectors with metal strips to highly complicated double-sided AC-coupled junction detectors. The feature of AC-coupling the readout electrodes from the diode strips necessitates the manufacture of a separate biasing structure for the strips, which comprises a common bias line together with a means for preventing the signal from one strip from spreading to its neighbors through the bias line. The obvious solution to this is to bias the strips through individual high value resistors. These resistors can be integrated on the detector wafer by depositing a layer of resistive polycrystalline silicon and patterning it to form the individual resistors. To circumvent the extra processing step required for polysilicon resistor processing and the rather difficult tuning of the process to obtain uniform and high enough resistance values throughout the large detector area, alternative methods for strip biasing have been devised. These include the usage of electron accumulation layer resistance for N{sup +}{minus} strips or the usage of the phenomenon known as the punch-through effect for P{sup +}{minus} strips. In this paper we present measurement results about the operation and radiation resistance of detectors with a punch-through effect based biasing structure known as a Field OXide Field-Effect Transistor (FOXFET), and present a model describing the FOXFET behavior. The studied detectors were prototypes for detectors to be used in the CDF silicon vertex detector upgrade.

  2. Evaluation of FOXFET biased ac-coupled silicon strip detector prototypes for CDF SVX upgrade

    International Nuclear Information System (INIS)

    Laakso, M.

    1992-03-01

    Silicon microstrip detectors for high-precision charged particle position measurements have been used in nuclear and particle physics for years. The detectors have evolved from simple surface barrier strip detectors with metal strips to highly complicated double-sided AC-coupled junction detectors. The feature of AC-coupling the readout electrodes from the diode strips necessitates the manufacture of a separate biasing structure for the strips, which comprises a common bias line together with a means for preventing the signal from one strip from spreading to its neighbors through the bias line. The obvious solution to this is to bias the strips through individual high value resistors. These resistors can be integrated on the detector wafer by depositing a layer of resistive polycrystalline silicon and patterning it to form the individual resistors. To circumvent the extra processing step required for polysilicon resistor processing and the rather difficult tuning of the process to obtain uniform and high enough resistance values throughout the large detector area, alternative methods for strip biasing have been devised. These include the usage of electron accumulation layer resistance for N + - strips or the usage of the phenomenon known as the punch-through effect for P + - strips. In this paper we present measurement results about the operation and radiation resistance of detectors with a punch-through effect based biasing structure known as a Field OXide Field-Effect Transistor (FOXFET), and present a model describing the FOXFET behavior. The studied detectors were prototypes for detectors to be used in the CDF silicon vertex detector upgrade

  3. Study of the technics of coating stripping and FBG writing on polyimide fiber

    Science.gov (United States)

    Song, ZhiQiang; Qi, HaiFeng; Ni, JiaSheng; Wang, Chang

    2017-10-01

    Compared with ordinary optical fiber, polyimide fiber has the characteristics of high temperature resistance and high strength, which has important application in the field of optical fiber sensing. The common methods of polyimide coating stripping were introduced in this paper, including high temperature stripping, chemical stripping and arc ablation. In order to meet the requirements of FBG writing technology, a method using argon ion laser ablation coating was proposed. The method can precisely control the stripping length of the coating and completely does not affect the tensile strength of the optical fiber. According to the experiment, the fabrication process of polyimide FBG is stripping-hydrogen loadingwriting. Under the same conditions, 10 FBG samples were fabricated with good uniformity of wavelength bandwidth and reflectivity. UV laser ablation of polyimide coating has been proved to be a safe, reliable and efficient method.

  4. HST IMAGING OF DUST STRUCTURES AND STARS IN THE RAM PRESSURE STRIPPED VIRGO SPIRALS NGC 4402 AND NGC 4522: STRIPPED FROM THE OUTSIDE IN WITH DENSE CLOUD DECOUPLING

    International Nuclear Information System (INIS)

    Abramson, A.; Kenney, J.; Crowl, H.; Tal, T.

    2016-01-01

    We describe and constrain the origins of interstellar medium (ISM) structures likely created by ongoing intracluster medium (ICM) ram pressure stripping in two Virgo Cluster spirals, NGC 4522 and NGC 4402, using Hubble Space Telescope (HST) BVI images of dust extinction and stars, as well as supplementary H i, H α , and radio continuum images. With a spatial resolution of ∼10 pc in the HST images, this is the highest-resolution study to date of the physical processes that occur during an ICM–ISM ram pressure stripping interaction, ram pressure stripping's effects on the multi-phase, multi-density ISM, and the formation and evolution of ram-pressure-stripped tails. In dust extinction, we view the leading side of NGC 4402 and the trailing side of NGC 4522, and so we see distinct types of features in both. In both galaxies, we identify some regions where dense clouds are decoupling or have decoupled and others where it appears that kiloparsec-sized sections of the ISM are moving coherently. NGC 4522 has experienced stronger, more recent pressure and has the “jellyfish” morphology characteristic of some ram-pressure-stripped galaxies. Its stripped tail extends up from the disk plane in continuous upturns of dust and stars curving up to ∼2 kpc above the disk plane. On the other side of the galaxy, there is a kinematically and morphologically distinct extraplanar arm of young, blue stars and ISM above a mostly stripped portion of the disk, and between it and the disk plane are decoupled dust clouds that have not been completely stripped. The leading side of NGC 4402 contains two kiloparsec-scale linear dust filaments with complex substructure that have partially decoupled from the surrounding ISM. NGC 4402 also contains long dust ridges, suggesting that large parts of the ISM are being pushed out at once. Both galaxies contain long ridges of polarized radio continuum emission indicating the presence of large-scale, ordered magnetic fields. We propose that

  5. The bacterial contamination rate of glucose meter test strips in the hospital setting

    Science.gov (United States)

    Al-Rubeaan, Khalid A.; Saeb, Amr T. M.; AlNaqeb, Dhekra M.; AlQumaidi, Hamed M.; AlMogbel, Turki A.

    2016-01-01

    Objectives: To assess the rate of bacterial contamination of the multi-use vial and single-use packed glucose meter strips, and to identify the type and frequency of various bacterial contamination in different hospital wards. Methods: This prospective observational study was conducted by a team from the Strategic Center for Diabetes Research in 7 general hospitals in the Central region of Saudi Arabia during the period from August to September 2014 to assess the bacterial contamination rate of the unused strips. A total of 10,447 strips were cultured using proper agar media and incubated both aerobically and anaerobically. Results: The total bacterial contamination rate for the multi-use vials glucose strips was 31.7%, while single-use packed strips were not contaminated at all. Ministry of Health hospitals had the highest contamination rates compared with other hospitals. Critical, obstetric, and surgical wards had the highest bacterial isolates number, where most were in the risk group 3 according to the National Institute of Health guidelines. Staphylococcus species were the most common bacteria found. Conclusion: Glucose meter strips should be recognized as a source of bacterial contamination that could be behind serious hospital acquired infections. The hospital infection control team should adopt proper measures to implement protocols for glucose meter cleaning and glucose strips handling. PMID:27570855

  6. Choosing order of operations to accelerate strip structure analysis in parameter range

    Science.gov (United States)

    Kuksenko, S. P.; Akhunov, R. R.; Gazizov, T. R.

    2018-05-01

    The paper considers the issue of using iteration methods in solving the sequence of linear algebraic systems obtained in quasistatic analysis of strip structures with the method of moments. Using the analysis of 4 strip structures, the authors have proved that additional acceleration (up to 2.21 times) of the iterative process can be obtained during the process of solving linear systems repeatedly by means of choosing a proper order of operations and a preconditioner. The obtained results can be used to accelerate the process of computer-aided design of various strip structures. The choice of the order of operations to accelerate the process is quite simple, universal and could be used not only for strip structure analysis but also for a wide range of computational problems.

  7. Analytic functions of several complex variables

    CERN Document Server

    Gunning, Robert C

    2009-01-01

    The theory of analytic functions of several complex variables enjoyed a period of remarkable development in the middle part of the twentieth century. After initial successes by Poincaré and others in the late 19th and early 20th centuries, the theory encountered obstacles that prevented it from growing quickly into an analogue of the theory for functions of one complex variable. Beginning in the 1930s, initially through the work of Oka, then H. Cartan, and continuing with the work of Grauert, Remmert, and others, new tools were introduced into the theory of several complex variables that resol

  8. Strip-Bark Morphology and Radial Growth Trends in Ancient Pinus sibirica Trees From Central Mongolia

    Science.gov (United States)

    Leland, Caroline; Cook, Edward R.; Andreu-Hayles, Laia; Pederson, Neil; Hessl, Amy; Anchukaitis, Kevin J.; Byambasuren, Oyunsanaa; Nachin, Baatarbileg; Davi, Nicole; D'Arrigo, Rosanne; Griffin, Kevin; Bishop, Daniel A.; Rao, Mukund Palat

    2018-03-01

    Some of the oldest and most important trees used for dendroclimatic reconstructions develop strip-bark morphology, in which only a portion of the stem contains living tissue. Yet the ecophysiological factors initiating strip bark and the potential effect of cambial dieback on annual ring widths and tree-ring estimates of past climate remain poorly understood. Using a combination of field observations and tree-ring data, we investigate the causes and timing of cambial dieback events in Pinus sibirica strip-bark trees from central Mongolia and compare the radial growth rates and trends of strip-bark and whole-bark trees over the past 515 years. Results indicate that strip bark is more common on the southern aspect of trees, and dieback events were most prevalent in the 19th century, a cold and dry period. Further, strip-bark and whole-bark trees have differing centennial trends, with strip-bark trees exhibiting notably large increases in ring widths at the beginning of the 20th century. We find a steeper positive trend in the strip-bark chronology relative to the whole-bark chronology when standardizing with age-dependent splines. We hypothesize that localized warming on the southern side of stems due to solar irradiance results in physiological damage and dieback and leads to increasing tree-ring increment along the living portion of strip-bark trees. Because the impact of cambial dieback on ring widths likely varies depending on species and site, we suggest conducting a comparison of strip-bark and whole-bark ring widths before statistically treating ring-width data for climate reconstructions.

  9. Dispersion Theory of Direct Nuclear Reactions

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, I. S. [Institute Of Theoretical And Experimental Physics, Moscow, USSR (Russian Federation)

    1963-01-15

    reasons for the agreement if it is not accidental. In short, the theory behaves like an unpredictable person. A major success in the application of perturbation theory to direct processes in the Butler theory of deuteron stripping ((d, p), (d, n)) and pick-up ((p, d), (n, d)). The Butler theory satisfactorily predicts the position of the first maximum (by the increase of the angle) in the angular distribution of reaction products as a function of the orbital momentum of the nucleon captured by the nucleus (stripping reaction) or picked up by an incident particle (pick- up reaction). This result permitted the use of stripping and pick-up reactions in nuclear spectroscopy. At the same time this led to the problem of understanding the true meaning of the Butler approximation. This problem was also essential because the Butler theory inadequately describes several other features of the stripping and pick-up reactions (such as the change of angular distribution with the energy of incident particles, the relation of intensities at the maxima of angular distributions, absolute values of. cross-sections and, sometimes, the relative probabilities for the excitation of different states of residual nuclei). A new method in direct process theory was offered not so long ago (in 1961). The method is based on fairly general properties of the reaction amplitudes and is free from the un-justified assumptions, of the form er theory, in particular the application of perturbation theory. This method makes it possible to obtain several new results and obtain a uniform description cf a great variety of processes (such as direct reactions of the conventional type at low and medium energies, the transfer of nucleons in the bombardment of nuclei by multi-charged ions and the processes of fragmentation at high energies). At the same time the new approach explains, with surprising simplicity, the causes of the form erly enigmatic success of the Butler theory and indicates the limits of its

  10. Dispersion Theory of Direct Nuclear Reactions

    International Nuclear Information System (INIS)

    Shapiro, I.S.

    1963-01-01

    reasons for the agreement if it is not accidental. In short, the theory behaves like an unpredictable person. A major success in the application of perturbation theory to direct processes in the Butler theory of deuteron stripping ((d, p), (d, n)) and pick-up ((p, d), (n, d)). The Butler theory satisfactorily predicts the position of the first maximum (by the increase of the angle) in the angular distribution of reaction products as a function of the orbital momentum of the nucleon captured by the nucleus (stripping reaction) or picked up by an incident particle (pick- up reaction). This result permitted the use of stripping and pick-up reactions in nuclear spectroscopy. At the same time this led to the problem of understanding the true meaning of the Butler approximation. This problem was also essential because the Butler theory inadequately describes several other features of the stripping and pick-up reactions (such as the change of angular distribution with the energy of incident particles, the relation of intensities at the maxima of angular distributions, absolute values of. cross-sections and, sometimes, the relative probabilities for the excitation of different states of residual nuclei). A new method in direct process theory was offered not so long ago (in 1961). The method is based on fairly general properties of the reaction amplitudes and is free from the un-justified assumptions, of the form er theory, in particular the application of perturbation theory. This method makes it possible to obtain several new results and obtain a uniform description cf a great variety of processes (such as direct reactions of the conventional type at low and medium energies, the transfer of nucleons in the bombardment of nuclei by multi-charged ions and the processes of fragmentation at high energies). At the same time the new approach explains, with surprising simplicity, the causes of the form erly enigmatic success of the Butler theory and indicates the limits of its

  11. Analysis of Lead and Zinc by Mercury-Free Potentiometric Stripping Analysis

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    1997-01-01

    A method is presented for trace-element analysis of lead and zinc by potentiometric stripping analysis (PSA) where both the glassy-carbon working electrode and the electrolyte are free of mercury. Analysis of zinc requires an activation procedure of the glassy-carbon electrode. The activation...... is performed by pre-concentrating zinc on glassy carbon at -1400 mV(SCE) in a mercury-free electrolyte containing 0.1 M HCl and 2 ppm Zn2+, followed by stripping at approx. -1050 mV. A linear relationship between stripping peak areas, recorded in the derivative mode, and concentration was found...

  12. Equation of state of a hard core fluid with a two-Yukawa tail: toward a simple analytic theory

    International Nuclear Information System (INIS)

    Jedrzejek, C.

    1980-01-01

    Thermodynamic properties of simple fluids are calculated using variational theory for a system of hard-core potential with a two-Yukawa tail. Likewise one Yukawa-tail case the working formulas are analytic. Five parameters of the two Yukawa system are chosen so as to get the best fit to a real argon potential or an ''argon-like'' Lennard-Jones potential. The results are fairly good in light of the extreme simplicity of the method. The discrepancies result from using the variational method and a different shape of Yukawa type potential in comparision to the real argon and Lennard-Jones potentials. (author)

  13. Stripping analysis of nanomolar perchlorate in drinking water with a voltammetric ion-selective electrode based on thin-layer liquid membrane.

    Science.gov (United States)

    Kim, Yushin; Amemiya, Shigeru

    2008-08-01

    A highly sensitive analytical method is required for the assessment of nanomolar perchlorate contamination in drinking water as an emerging environmental problem. We developed the novel approach based on a voltammetric ion-selective electrode to enable the electrochemical detection of "redox-inactive" perchlorate at a nanomolar level without its electrolysis. The perchlorate-selective electrode is based on the submicrometer-thick plasticized poly(vinyl chloride) membrane spin-coated on the poly(3-octylthiophene)-modified gold electrode. The liquid membrane serves as the first thin-layer cell for ion-transfer stripping voltammetry to give low detection limits of 0.2-0.5 nM perchlorate in deionized water, commercial bottled water, and tap water under a rotating electrode configuration. The detection limits are not only much lower than the action limit (approximately 246 nM) set by the U.S. Environmental Protection Agency but also are comparable to the detection limits of the most sensitive analytical methods for detecting perchlorate, that is, ion chromatography coupled with a suppressed conductivity detector (0.55 nM) or electrospray ionization mass spectrometry (0.20-0.25 nM). The mass transfer of perchlorate in the thin-layer liquid membrane and aqueous sample as well as its transfer at the interface between the two phases were studied experimentally and theoretically to achieve the low detection limits. The advantages of ion-transfer stripping voltammetry with a thin-layer liquid membrane against traditional ion-selective potentiometry are demonstrated in terms of a detection limit, a response time, and selectivity.

  14. Analytic functionals on the sphere

    CERN Document Server

    Morimoto, Mitsuo

    1998-01-01

    This book treats spherical harmonic expansion of real analytic functions and hyperfunctions on the sphere. Because a one-dimensional sphere is a circle, the simplest example of the theory is that of Fourier series of periodic functions. The author first introduces a system of complex neighborhoods of the sphere by means of the Lie norm. He then studies holomorphic functions and analytic functionals on the complex sphere. In the one-dimensional case, this corresponds to the study of holomorphic functions and analytic functionals on the annular set in the complex plane, relying on the Laurent series expansion. In this volume, it is shown that the same idea still works in a higher-dimensional sphere. The Fourier-Borel transformation of analytic functionals on the sphere is also examined; the eigenfunction of the Laplacian can be studied in this way.

  15. 2016 Gainesville Number Theory Conference

    CERN Document Server

    Garvan, Frank

    2017-01-01

    Gathered from the 2016 Gainesville Number Theory Conference honoring Krishna Alladi on his 60th birthday, these proceedings present recent research in number theory. Extensive and detailed, this volume features 40 articles by leading researchers on topics in analytic number theory, probabilistic number theory, irrationality and transcendence, Diophantine analysis, partitions, basic hypergeometric series, and modular forms. Readers will also find detailed discussions of several aspects of the path-breaking work of Srinivasa Ramanujan and its influence on current research. Many of the papers were motivated by Alladi's own research on partitions and q-series as well as his earlier work in number theory.  Alladi is well known for his contributions in number theory and mathematics. His research interests include combinatorics, discrete mathematics, sieve methods, probabilistic and analytic number theory, Diophantine approximations, partitions and q-series identities. Graduate students and researchers will find th...

  16. Analytical multiple scattering correction to the Mie theory: Application to the analysis of the lidar signal

    Science.gov (United States)

    Flesia, C.; Schwendimann, P.

    1992-01-01

    The contribution of the multiple scattering to the lidar signal is dependent on the optical depth tau. Therefore, the radar analysis, based on the assumption that the multiple scattering can be neglected is limited to cases characterized by low values of the optical depth (tau less than or equal to 0.1) and hence it exclude scattering from most clouds. Moreover, all inversion methods relating lidar signal to number densities and particle size must be modified since the multiple scattering affects the direct analysis. The essential requests of a realistic model for lidar measurements which include the multiple scattering and which can be applied to practical situations follow. (1) Requested are not only a correction term or a rough approximation describing results of a certain experiment, but a general theory of multiple scattering tying together the relevant physical parameter we seek to measure. (2) An analytical generalization of the lidar equation which can be applied in the case of a realistic aerosol is requested. A pure analytical formulation is important in order to avoid the convergency and stability problems which, in the case of numerical approach, are due to the large number of events that have to be taken into account in the presence of large depth and/or a strong experimental noise.

  17. Continuous liquid sheet generator for ion stripping

    International Nuclear Information System (INIS)

    Gavin, B.; Batson, P.; Leemann, B.; Rude, B.

    1984-10-01

    Many of the technical problems of generating a large thin liquid sheet from 0.02 to 0.20 μm thick (3 to 40 μgm/cm 2 ) have been solved. It is shown that this perennial sheet is stable and consonant in dimension. Several ion beam species from the SuperHILAC have been used for evaluation; at 0.11 MeV/n. In one of three modes this sheet serves as an equivalent substitute for a carbon foil. The second mode is characterized by a solid-like charge state distribution but with a varying fraction of unstripped ions. The third mode gives stripping performance akin to a vapor stripping medium. 9 references, 7 figures

  18. Cascade air stripping: Techno-economic evaluation of a new ground water treatment process

    International Nuclear Information System (INIS)

    Nirmalakhandan, N.; Peace, G.L.; Shanbhag, A.R.; Speece, R.E.

    1992-01-01

    A simple modification of the conventional air-stripping process introduced as cascade air stripping is proposed for efficient and economical removal of semivolatile and low volatility contaminants from ground water. The technical feasibility and economic viability of this process are evaluated using field test results and cost model simulations. The field tests enabled the process model to be verified at various water flow rates ranging from 150 gpm to 400 gpm. The field study also demonstrated the feasibility of the proposed system at a near full-scale level. Cost models were used to compare the proposed process to conventional air stripping and granular-activated carbon adsorption in removing a range of contaminants. This analysis showed that the treatment cost (cents/1,000 gal) of cascade air stripping is about 15% lower than conventional air stripping and about 40% lower than granular-activated carbon adsorption

  19. MOBIUS-STRIP-LIKE COLUMNAR FUNCTIONAL CONNECTIONS ARE REVEALED IN SOMATO-SENSORY RECEPTIVE FIELD CENTROIDS.

    Directory of Open Access Journals (Sweden)

    James Joseph Wright

    2014-10-01

    Full Text Available Receptive fields of neurons in the forelimb region of areas 3b and 1 of primary somatosensory cortex, in cats and monkeys, were mapped using extracellular recordings obtained sequentially from nearly radial penetrations. Locations of the field centroids indicated the presence of a functional system, in which cortical homotypic representations of the limb surfaces are entwined in three-dimensional Mobius-strip-like patterns of synaptic connections. Boundaries of somatosensory receptive field in nested groups irregularly overlie the centroid order, and are interpreted as arising from the superposition of learned connections upon the embryonic order. Since the theory of embryonic synaptic self-organisation used to model these results was devised and earlier used to explain findings in primary visual cortex, the present findings suggest the theory may be of general application throughout cortex, and may reveal a modular functional synaptic system, which, only in some parts of the cortex, and in some species, is manifest as anatomical ordering into columns.

  20. Air Stripping Designs and Reactive Water Purification Processes for the Lunar Surface

    Science.gov (United States)

    Boul, Peter J.; Lange, Kevin; Conger, Bruce; Anderson, Molly

    2010-01-01

    Air stripping designs are considered to reduce the presence of volatile organic compounds in the purified water. Components of the wastewater streams are ranked by Henry's Law Constant and the suitability of air stripping in the purification of wastewater in terms of component removal is evaluated. Distillation processes are modeled in tandem with air stripping to demonstrate the potential effectiveness and utility of these methods in recycling wastewater on the Moon. Scaling factors for distillation and air stripping columns are presented to account for the difference in the lunar gravitation environment. Commercially available distillation and air stripping units which are considered suitable for Exploration Life Support are presented. The advantages to the various designs are summarized with respect to water purity levels, power consumption, and processing rates. An evaluation of reactive distillation and air stripping is presented with regards to the reduction of volatile organic compounds in the contaminated water and air. Among the methods presented, an architecture is presented for the evaluation of the simultaneous oxidation of organics in air and water. These and other designs are presented in light of potential improvements in power consumptions and air and water purities for architectures which include catalytic activity integrated into the water processor. In particular, catalytic oxidation of organics may be useful as a tool to remove contaminants that more traditional distillation and/or air stripping columns may not remove. A review of the current leading edge at the commercial level and at the research frontier in catalytically active materials is presented. Themes and directions from the engineering developments in catalyst design are presented conceptually in light of developments in the nanoscale chemistry of a variety of catalyst materials.

  1. ATLAS ITk Strip Detector for High-Luminosity LHC

    CERN Document Server

    Kroll, Jiri; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment is currently preparing for an upgrade of the tracking system in the course of the High-Luminosity LHC that is scheduled for 2026. The expected peak instantaneous luminosity up to 7.5E34 per second and cm2 corresponding to approximately 200 inelastic proton-proton interactions per beam crossing, radiation damage at an integrated luminosity of 3000/fb and hadron fluencies over 1E16 1 MeV neutron equivalent per cm2, as well as fast hardware tracking capability that will bring Level-0 trigger rate of a few MHz down to a Level-1 trigger rate below 1 MHz require a replacement of existing Inner Detector by an all-silicon Inner Tracker (ITk) with a pixel detector surrounded by a strip detector. The current prototyping phase, that is working with ITk Strip Detector consisting of a four-layer barrel and a forward region composed of six discs on each side of the barrel, has resulted in the ATLAS ITk Strip Detector Technical Design Report (TDR), which starts the pre-production readiness phase at the ...

  2. The ATLAS tracker strip detector for HL-LHC

    CERN Document Server

    Cormier, Kyle James Read; The ATLAS collaboration

    2016-01-01

    As part of the ATLAS upgrades for the High Luminsotiy LHC (HL-LHC) the current ATLAS Inner Detector (ID) will be replaced by a new Inner Tracker (ITk). The ITk will consist of two main components: semi-conductor pixels at the innermost radii, and silicon strips covering larger radii out as far as the ATLAS solenoid magnet including the volume currently occupied by the ATLAS Transition Radiation Tracker (TRT). The primary challenges faced by the ITk are the higher planned read out rate of ATLAS, the high density of charged particles in HL-LHC conditions for which tracks need to be resolved, and the corresponding high radiation doses that the detector and electronics will receive. The ITk strips community is currently working on designing and testing all aspects of the sensors, readout, mechanics, cooling and integration to meet these goals and a Technical Design Report is being prepared. This talk is an overview of the strip detector component of the ITk, highlighting the current status and the road ahead.

  3. The ATLAS tracker strip detector for HL-LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00512833; The ATLAS collaboration

    2017-01-01

    As part of the ATLAS upgrades for the High Luminsotiy LHC (HL-LHC) the current ATLAS Inner Detector (ID) will be replaced by a new Inner Tracker (ITk). The ITk will consist of two main components: semi-conductor pixels at the innermost radii, and silicon strips covering larger radii out as far as the ATLAS solenoid magnet including the volume currently occupied by the ATLAS Transition Radiation Tracker (TRT). The primary challenges faced by the ITk are the higher planned read out rate of ATLAS, the high density of charged particles in HL-LHC conditions for which tracks need to be resolved, and the corresponding high radiation doses that the detector and electronics will receive. The ITk strips community is currently working on designing and testing all aspects of the sensors, readout, mechanics, cooling and integration to meet these goals and a Technical Design Report is being prepared. This talk is an overview of the strip detector component of the ITk, highlighting the current status and the road ahead.

  4. Fabrication of double-sided thallium bromide strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hitomi, Keitaro, E-mail: keitaro.hitomi@qse.tohoku.ac.jp [Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai 980-8579 (Japan); Nagano, Nobumichi [Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai 980-8579 (Japan); Onodera, Toshiyuki [Department of Electronics and Intelligent Systems, Tohoku Institute of Technology, Sendai 982-8577 (Japan); Kim, Seong-Yun; Ito, Tatsuya; Ishii, Keizo [Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai 980-8579 (Japan)

    2016-07-01

    Double-sided strip detectors were fabricated from thallium bromide (TlBr) crystals grown by the traveling-molten zone method using zone-purified materials. The detectors had three 3.4-mm-long strips with 1-mm widths and a surrounding electrode placed orthogonally on opposite surfaces of the crystals at approximately 6.5×6.5 mm{sup 2} in area and 5 mm in thickness. Excellent charge transport properties for both electrons and holes were observed from the TlBr crystals. The mobility-lifetime products for electrons and holes in the detector were measured to be ~3×10{sup −3} cm{sup 2}/V and ~1×10{sup −3} cm{sup 2}/V, respectively. The {sup 137}Cs spectra corresponding to the gamma-ray interaction position were obtained from the detector. An energy resolution of 3.4% of full width at half maximum for 662-keV gamma rays was obtained from one “pixel” (an intersection of the strips) of the detector at room temperature.

  5. ATLAS ITk Strip Detector for High-Luminosity LHC

    CERN Document Server

    Kroll, Jiri; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment is currently preparing for an upgrade of the tracking system in the course of the High-Luminosity LHC that is scheduled for 2026. The expected peak instantaneous luminosity up to $7.5\\times10^{34}\\;\\mathrm{cm}^{-2}\\mathrm{s}^{-1}$ corresponding to approximately 200 inelastic proton-proton interactions per beam crossing, radiation damage at an integrated luminosity of $3000\\;\\mathrm{fb}^{-1}$ and hadron fluencies over $2\\times10^{16}\\;\\mathrm{n}_{\\mathrm{eq}}/\\mathrm{cm}^{2}$, as well as fast hardware tracking capability that will bring Level-0 trigger rate of a few MHz down to a Level-1 trigger rate below 1 MHz require a replacement of existing Inner Detector by an all-silicon Inner Tracker with a pixel detector surrounded by a strip detector. The current prototyping phase, that is working with ITk Strip Detector consisting of a four-layer barrel and a forward region composed of six disks on each side of the barrel, has resulted in the ATLAS Inner Tracker Strip Detector Technical Design R...

  6. Simulation of accelerated strip cooling on the hot rolling mill run-out roller table

    International Nuclear Information System (INIS)

    Muhin, U.; Belskij, S.; Makarov, E.; Koinov, T.

    2013-01-01

    Full text: A mathematical model of the thermal state of the metal on the run-out roller table of a continuous wide hot-strip mill is presented. The mathematical model takes into account the heat generation during the polymorphic γ → α transformation of super cooled austenite phase and the influence of chemical composition on the physical properties of the steel. The model allows the calculation of modes of accelerated cooling of strips on the run-out roller table of a continuous wide hot strip mill. Winding temperature calculation error does not exceed 20 °C for 98.5 % of the strips from low-carbon and low-alloyed steels. key words: hot rolled, wide-strip, accelerated cooling, run-out roller table, polymorphic transformation, mathematical modeling

  7. The Strip Silicon Photo-Multiplier: An innovation for enhanced time and position measurement

    Energy Technology Data Exchange (ETDEWEB)

    Doroud, K., E-mail: Katayoun.Doroud@cern.ch [CERN, Geneva (Switzerland); Williams, M.C.S. [CERN, Geneva (Switzerland); INFN, Bologna (Italy); Yamamoto, K. [Solid State Division, Hamamatsu Photonics K.K., Hamamatsu (Japan)

    2017-05-01

    There is considerable R&D concerning precise time measurement from a variety of detectors, and in particular for the Silicon PhotoMultiplier (SiPM). In this paper we discuss a new geometry for the SiPM in the form of a strip. A strip can be read out at both end, with each end coupled to an individual TDC (time to digital converter). The time difference is related to the position of the firing SPAD along the length of the strip, while the average of the two times gives the time of the hit. Results from the testing of the first prototype Strip SiPMs are presented in this paper.

  8. Analytical applications of ion exchangers

    CERN Document Server

    Inczédy, J

    1966-01-01

    Analytical Applications of Ion Exchangers presents the laboratory use of ion-exchange resins. This book discusses the development in the analytical application of ion exchangers. Organized into 10 chapters, this book begins with an overview of the history and significance of ion exchangers for technical purposes. This text then describes the properties of ion exchangers, which are large molecular water-insoluble polyelectrolytes having a cross-linked structure that contains ionic groups. Other chapters consider the theories concerning the operation of ion-exchange resins and investigate th

  9. Extraction and stripping of neodymium (III) and dysprosium (III) by TRUEX solvent

    International Nuclear Information System (INIS)

    Rout, Alok; Venkatesan, K.A.; Antony, M.P.; Srinivasan, T.G.; Vasudeva Rao, P.R.

    2009-01-01

    McCabe-Thiele diagram for the extraction and stripping of Nd (III) and Dy (III) by TRUEX solvent has been constructed to determine the number of stages required for complete extraction and stripping. (author)

  10. Large-scale module production for the CMS silicon strip tracker

    CERN Document Server

    Cattai, A

    2005-01-01

    The Silicon Strip Tracker (SST) for the CMS experiment at LHC consists of 210 m**2 of silicon strip detectors grouped into four distinct sub-systems. We present a brief description of the CMS Tracker, the industrialised detector module production methods and the current status of the SST with reference to some problems encountered at the factories and in the construction centres.

  11. Recent Developments in On-Line Assessment of Steel Strip Properties

    International Nuclear Information System (INIS)

    Meilland, P.; Kroos, J.; Buchholtz, O. W.; Hartmann, H.-J.

    2006-01-01

    On-line non-destructive assessment of steel strip properties is a subject of growing interest amongst European manufacturers, as it provides information all along the products length, without slowing down the production. Arcelor, Salzgitter and TKS recently undertook a collective effort to assess the performance of 3 systems for flat carbon steel strips mechanical properties at the exit of galvanizing lines

  12. Electrochemistry

    International Nuclear Information System (INIS)

    Baek, Un Gi; Park, Su Mun

    2001-02-01

    This book starts introduction of electrochemistry, it describes reaction, cell, potentiometry glass electrode, Gouy-Chapman's theory, speed of electrode reaction, electrolyte solution with Debye-Huckel's theory, electrolyte conduction and diffusion, test way like coulometry and diffusion, test way like coulometry and rotated electrode, AC measurement and impedance, AC voltammetry, ellipsometry, electro analytical chemistry with anodic stripping voltametry and electrochemical sensors, electrochemistry material and reaction, electrochemistry and five appendixes.

  13. Phonon thermal conductance of disordered graphene strips with armchair edges

    International Nuclear Information System (INIS)

    Shi Lipeng; Xiong Shijie

    2009-01-01

    Based on the model of lattice dynamics together with the transfer matrix technique, we investigate the thermal conductances of phonons in quasi-one-dimensional disordered graphene strips with armchair edges using Landauer formalism for thermal transport. It is found that the contributions to thermal conductance from the phonon transport near von Hove singularities is significantly suppressed by the presence of disorder, on the contrary to the effect of disorder on phonon modes in other frequency regions. Besides the magnitude, for different widths of the strips, the thermal conductance also shows different temperature dependence. At low temperatures, the thermal conductance displays quantized features of both pure and disordered graphene strips implying that the transmission of phonon modes at low frequencies are almost unaffected by the disorder

  14. Study of surface properties of ATLAS12 strip sensors and their radiation resistance

    Science.gov (United States)

    Mikestikova, M.; Allport, P. P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J. P.; Wilson, J. A.; Kierstead, J.; Kuczewski, P.; Lynn, D.; Hommels, L. B. A.; Ullan, M.; Bloch, I.; Gregor, I. M.; Tackmann, K.; Hauser, M.; Jakobs, K.; Kuehn, S.; Mahboubi, K.; Mori, R.; Parzefall, U.; Clark, A.; Ferrere, D.; Sevilla, S. Gonzalez; Ashby, J.; Blue, A.; Bates, R.; Buttar, C.; Doherty, F.; McMullen, T.; McEwan, F.; O'Shea, V.; Kamada, S.; Yamamura, K.; Ikegami, Y.; Nakamura, K.; Takubo, Y.; Unno, Y.; Takashima, R.; Chilingarov, A.; Fox, H.; Affolder, A. A.; Casse, G.; Dervan, P.; Forshaw, D.; Greenall, A.; Wonsak, S.; Wormald, M.; Cindro, V.; Kramberger, G.; Mandić, I.; Mikuž, M.; Gorelov, I.; Hoeferkamp, M.; Palni, P.; Seidel, S.; Taylor, A.; Toms, K.; Wang, R.; Hessey, N. P.; Valencic, N.; Hanagaki, K.; Dolezal, Z.; Kodys, P.; Bohm, J.; Stastny, J.; Bevan, A.; Beck, G.; Milke, C.; Domingo, M.; Fadeyev, V.; Galloway, Z.; Hibbard-Lubow, D.; Liang, Z.; Sadrozinski, H. F.-W.; Seiden, A.; To, K.; French, R.; Hodgson, P.; Marin-Reyes, H.; Parker, K.; Jinnouchi, O.; Hara, K.; Sato, K.; Hagihara, M.; Iwabuchi, S.; Bernabeu, J.; Civera, J. V.; Garcia, C.; Lacasta, C.; Marti i Garcia, S.; Rodriguez, D.; Santoyo, D.; Solaz, C.; Soldevila, U.

    2016-09-01

    A radiation hard n+-in-p micro-strip sensor for the use in the Upgrade of the strip tracker of the ATLAS experiment at the High Luminosity Large Hadron Collider (HL-LHC) has been developed by the "ATLAS ITk Strip Sensor collaboration" and produced by Hamamatsu Photonics. Surface properties of different types of end-cap and barrel miniature sensors of the latest sensor design ATLAS12 have been studied before and after irradiation. The tested barrel sensors vary in "punch-through protection" (PTP) structure, and the end-cap sensors, whose stereo-strips differ in fan geometry, in strip pitch and in edge strip ganging options. Sensors have been irradiated with proton fluences of up to 1×1016 neq/cm2, by reactor neutron fluence of 1×1015 neq/cm2 and by gamma rays from 60Co up to dose of 1 MGy. The main goal of the present study is to characterize the leakage current for micro-discharge breakdown voltage estimation, the inter-strip resistance and capacitance, the bias resistance and the effectiveness of PTP structures as a function of bias voltage and fluence. It has been verified that the ATLAS12 sensors have high breakdown voltage well above the operational voltage which implies that different geometries of sensors do not influence their stability. The inter-strip isolation is a strong function of irradiation fluence, however the sensor performance is acceptable in the expected range for HL-LHC. New gated PTP structure exhibits low PTP onset voltage and sharp cut-off of effective resistance even at the highest tested radiation fluence. The inter-strip capacitance complies with the technical specification required before irradiation and no radiation-induced degradation was observed. A summary of ATLAS12 sensors tests is presented including a comparison of results from different irradiation sites. The measured characteristics are compared with the previous prototype of the sensor design, ATLAS07.

  15. Investigation of Mercury Reduction in Gold Stripping Process at Elevated Temperature

    Science.gov (United States)

    Pramudya, Irawan

    Mercury is present in many gold ores. By processing these ores, there is a potential of emitting mercury to the environment. Carbon regeneration kiln stacks have been observed as one of the primary source of mercury emission into the atmosphere. Before it is recycled back into the carbon in leach (CIL) or carbon in columns (CIC), carbon used in the gold extraction process needs to be reactivated thermally. Emission of mercury can be minimized by keeping the mercury left in the carbon low before it goes to the carbon regeneration kiln stacks. The objective of this study is establishing the optimum elution conditions of mercury cyanide from loaded carbon (which includes the eluent, concentration, temperature and elution time) with respect to gold stripping. Several methods such as acid washing (UNR-100, HCl or ethanol/UNR-100) were investigated prior to the stripping process. Furthermore, conventional pressurized Zadra and modified Zadra were also studied with regards to mercury concentration in the solution and vapor state as well as maximizing the gold stripping from industrial loaded carbon. 7% UNR-100 acid washing of loaded carbon at 80°C was able to wash out approximately 90% of mercury while maintaining the gold adsorption on the carbon (selective washing). The addition of alcohol in the UNR-100 acid washing solution was able to enhance mercury washing from 90% to 97%. Furthermore, mercury stripping using conventional pressurized (cyanide-alkaline) Zadra was best performed at 80°C (minimal amount of mercury reduced and volatilized) whereas using the same process only 40% of gold was stripped, which makes this process not viable. When alcohol was added to the stripping solution, at 80°C, 95% of gold was detected in the solution while keeping the reduction and volatilization of mercury low. The outcome of this study provides a better understanding of mercury behavior during the acid washing and stripping processes so that the risk of mercury exposure and

  16. Performance studies of the CMS Strip Tracker before installation

    CERN Document Server

    Adam, Wolfgang; Dragicevic, Marko; Friedl, Markus; Fruhwirth, R; Hansel, S; Hrubec, Josef; Krammer, Manfred; Oberegger, Margit; Pernicka, Manfred; Schmid, Siegfried; Stark, Roland; Steininger, Helmut; Uhl, Dieter; Waltenberger, Wolfgang; Widl, Edmund; Van Mechelen, Pierre; Cardaci, Marco; Beaumont, Willem; de Langhe, Eric; de Wolf, Eddi A; Delmeire, Evelyne; Hashemi, Majid; Bouhali, Othmane; Charaf, Otman; Clerbaux, Barbara; Dewulf, Jean-Paul; Elgammal, Sherif; Hammad, Gregory Habib; de Lentdecker, Gilles; Marage, Pierre Edouard; Vander Velde, Catherine; Vanlaer, Pascal; Wickens, John; Adler, Volker; Devroede, Olivier; De Weirdt, Stijn; D'Hondt, Jorgen; Goorens, Robert; Heyninck, Jan; Maes, Joris; Mozer, Matthias Ulrich; Tavernier, Stefaan; Van Lancker, Luc; Van Mulders, Petra; Villella, Ilaria; Wastiels, C; Bonnet, Jean-Luc; Bruno, Giacomo; De Callatay, Bernard; Florins, Benoit; Giammanco, Andrea; Gregoire, Ghislain; Keutgen, Thomas; Kcira, Dorian; Lemaitre, Vincent; Michotte, Daniel; Militaru, Otilia; Piotrzkowski, Krzysztof; Quertermont, L; Roberfroid, Vincent; Rouby, Xavier; Teyssier, Daniel; Daubie, Evelyne; Anttila, Erkki; Czellar, Sandor; Engstrom, Pauli; Harkonen, J; Karimaki, V; Kostesmaa, J; Kuronen, Auli; Lampen, Tapio; Linden, Tomas; Luukka, Panja-Riina; Maenpaa, T; Michal, Sebastien; Tuominen, Eija; Tuominiemi, Jorma; Ageron, Michel; Baulieu, Guillaume; Bonnevaux, Alain; Boudoul, Gaelle; Chabanat, Eric; Chabert, Eric Christian; Chierici, Roberto; Contardo, Didier; Della Negra, Rodolphe; Dupasquier, Thierry; Gelin, Georges; Giraud, Noël; Guillot, Gérard; Estre, Nicolas; Haroutunian, Roger; Lumb, Nicholas; Perries, Stephane; Schirra, Florent; Trocme, Benjamin; Vanzetto, Sylvain; Agram, Jean-Laurent; Blaes, Reiner; Drouhin, Frédéric; Ernenwein, Jean-Pierre; Fontaine, Jean-Charles; Berst, Jean-Daniel; Brom, Jean-Marie; Didierjean, Francois; Goerlach, Ulrich; Graehling, Philippe; Gross, Laurent; Hosselet, J; Juillot, Pierre; Lounis, Abdenour; Maazouzi, Chaker; Olivetto, Christian; Strub, Roger; Van Hove, Pierre; Anagnostou, Georgios; Brauer, Richard; Esser, Hans; Feld, Lutz; Karpinski, Waclaw; Klein, Katja; Kukulies, Christoph; Olzem, Jan; Ostapchuk, Andrey; Pandoulas, Demetrios; Pierschel, Gerhard; Raupach, Frank; Schael, Stefan; Schwering, Georg; Sprenger, Daniel; Thomas, Maarten; Weber, Markus; Wittmer, Bruno; Wlochal, Michael; Beissel, Franz; Bock, E; Flugge, G; Gillissen, C; Hermanns, Thomas; Heydhausen, Dirk; Jahn, Dieter; Kaussen, Gordon; Linn, Alexander; Perchalla, Lars; Poettgens, Michael; Pooth, Oliver; Stahl, Achim; Zoeller, Marc Henning; Buhmann, Peter; Butz, Erik; Flucke, Gero; Hamdorf, Richard Helmut; Hauk, Johannes; Klanner, Robert; Pein, Uwe; Schleper, Peter; Steinbruck, G; Blum, P; De Boer, Wim; Dierlamm, Alexander; Dirkes, Guido; Fahrer, Manuel; Frey, Martin; Furgeri, Alexander; Hartmann, Frank; Heier, Stefan; Hoffmann, Karl-Heinz; Kaminski, Jochen; Ledermann, Bernhard; Liamsuwan, Thiansin; Muller, S; Muller, Th; Schilling, Frank-Peter; Simonis, Hans-Jürgen; Steck, Pia; Zhukov, Valery; Cariola, P; De Robertis, Giuseppe; Ferorelli, Raffaele; Fiore, Luigi; Preda, M; Sala, Giuliano; Silvestris, Lucia; Tempesta, Paolo; Zito, Giuseppe; Creanza, Donato; De Filippis, Nicola; De Palma, Mauro; Giordano, Domenico; Maggi, Giorgio; Manna, Norman; My, Salvatore; Selvaggi, Giovanna; Albergo, Sebastiano; Chiorboli, Massimiliano; Costa, Salvatore; Galanti, Mario; Giudice, Nunzio; Guardone, Nunzio; Noto, Francesco; Potenza, Renato; Saizu, Mirela Angela; Sparti, V; Sutera, Concetta; Tricomi, Alessia; Tuve, Cristina; Brianzi, Mirko; Civinini, Carlo; Maletta, Fernando; Manolescu, Florentina; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Broccolo, B; Ciulli, Vitaliano; D'Alessandro, Raffaello; Focardi, Ettore; Frosali, Simone; Genta, Chiara; Landi, Gregorio; Lenzi, Piergiulio; Macchiolo, Anna; Magini, Nicolo; Parrini, Giuliano; Scarlini, Enrico; Cerati, Giuseppe Benedetto; Azzi, Patrizia; Bacchetta, Nicola; Candelori, Andrea; Dorigo, Tommaso; Kaminsky, A; Karaevski, S; Khomenkov, Volodymyr; Reznikov, Sergey; Tessaro, Mario; Bisello, Dario; De Mattia, Marco; Giubilato, Piero; Loreti, Maurizio; Mattiazzo, Serena; Nigro, Massimo; Paccagnella, Alessandro; Pantano, Devis; Pozzobon, Nicola; Tosi, Mia; Bilei, Gian Mario; Checcucci, Bruno; Fano, Livio; Servoli, Leonello; Ambroglini, Filippo; Babucci, Ezio; Benedetti, Daniele; Biasini, Maurizio; Caponeri, Benedetta; Covarelli, Roberto; Giorgi, Marco; Lariccia, Paolo; Mantovani, Giancarlo; Marcantonini, Marta; Postolache, Vasile; Santocchia, Attilio; Spiga, Daniele; Bagliesi, Giuseppe; Balestri, Gabriele; Berretta, Luca; Bianucci, S; Boccali, Tommaso; Bosi, Filippo; Bracci, Fabrizio; Castaldi, Rino; Ceccanti, Marco; Cecchi, Roberto; Cerri, Claudio; Cucoanes, Andi Sebastian; Dell'Orso, Roberto; Dobur, Didar; Dutta, Suchandra; Giassi, Alessandro; Giusti, Simone; Kartashov, Dmitry; Kraan, Aafke; Lomtadze, Teimuraz; Lungu, George-Adrian; Magazzu, Guido; Mammini, Paolo; Mariani, Filippo; Martinelli, Giovanni; Moggi, Andrea; Palla, Fabrizio; Palmonari, Francesco; Petragnani, Giulio; Profeti, Alessandro; Raffaelli, Fabrizio; Rizzi, Domenico; Sanguinetti, Giulio; Sarkar, Subir; Sentenac, Daniel; Serban, Alin Titus; Slav, Adrian; Soldani, A; Spagnolo, Paolo; Tenchini, Roberto; Tolaini, Sergio; Venturi, Andrea; Verdini, Piero Giorgio; Vos, Marcel; Zaccarelli, Luciano; Avanzini, Carlo; Basti, Andrea; Benucci, Leonardo; Bocci, Andrea; Cazzola, Ugo; Fiori, Francesco; Linari, Stefano; Massa, Maurizio; Messineo, Alberto; Segneri, Gabriele; Tonelli, Guido; Azzurri, Paolo; Bernardini, Jacopo; Borrello, Laura; Calzolari, Federico; Foa, Lorenzo; Gennai, Simone; Ligabue, Franco; Petrucciani, Giovanni; Rizzi, Andrea; Yang, Zong-Chang; Benotto, Franco; Demaria, Natale; Dumitrache, Floarea; Farano, R; Borgia, Maria Assunta; Castello, Roberto; Costa, Marco; Migliore, Ernesto; Romero, Alessandra; Abbaneo, Duccio; Abbas, M; Ahmed, Ijaz; Akhtar, I; Albert, Eric; Bloch, Christoph; Breuker, Horst; Butt, Shahid Aleem; Buchmuller, Oliver; Cattai, Ariella; Delaere, Christophe; Delattre, Michel; Edera, Laura Maria; Engstrom, Pauli; Eppard, Michael; Gateau, Maryline; Gill, Karl; Giolo-Nicollerat, Anne-Sylvie; Grabit, Robert; Honma, Alan; Huhtinen, Mika; Kloukinas, Kostas; Kortesmaa, Jarmo; Kottelat, Luc-Joseph; Kuronen, Auli; Leonardo, Nuno; Ljuslin, Christer; Mannelli, Marcello; Masetti, Lorenzo; Marchioro, Alessandro; Mersi, Stefano; Michal, Sebastien; Mirabito, Laurent; Muffat-Joly, Jeannine; Onnela, Antti; Paillard, Christian; Pal, Imre; Pernot, Jean-Francois; Petagna, Paolo; Petit, Patrick; Piccut, C; Pioppi, Michele; Postema, Hans; Ranieri, Riccardo; Ricci, Daniel; Rolandi, Gigi; Ronga, Frederic Jean; Sigaud, Christophe; Syed, A; Siegrist, Patrice; Tropea, Paola; Troska, Jan; Tsirou, Andromachi; Vander Donckt, Muriel; Vasey, François; Alagoz, Enver; Amsler, Claude; Chiochia, Vincenzo; Regenfus, Christian; Robmann, Peter; Rochet, Jacky; Rommerskirchen, Tanja; Schmidt, Alexander; Steiner, Stefan; Wilke, Lotte; Church, Ivan; Cole, Joanne; Coughlan, John A; Gay, Arnaud; Taghavi, S; Tomalin, Ian R; Bainbridge, Robert; Cripps, Nicholas; Fulcher, Jonathan; Hall, Geoffrey; Noy, Matthew; Pesaresi, Mark; Radicci, Valeria; Raymond, David Mark; Sharp, Peter; Stoye, Markus; Wingham, Matthew; Zorba, Osman; Goitom, Israel; Hobson, Peter R; Reid, Ivan; Teodorescu, Liliana; Hanson, Gail; Jeng, Geng-Yuan; Liu, Haidong; Pasztor, Gabriella; Satpathy, Asish; Stringer, Robert; Mangano, Boris; Affolder, K; Affolder, T; Allen, Andrea; Barge, Derek; Burke, Samuel; Callahan, D; Campagnari, Claudio; Crook, A; D'Alfonso, Mariarosaria; Dietch, J; Garberson, Jeffrey; Hale, David; Incandela, H; Incandela, Joe; Jaditz, Stephen; Kalavase, Puneeth; Kreyer, Steven Lawrence; Kyre, Susanne; Lamb, James; Mc Guinness, C; Mills, C; Nguyen, Harold; Nikolic, Milan; Lowette, Steven; Rebassoo, Finn; Ribnik, Jacob; Richman, Jeffrey; Rubinstein, Noah; Sanhueza, S; Shah, Yousaf Syed; Simms, L; Staszak, D; Stoner, J; Stuart, David; Swain, Sanjay Kumar; Vlimant, Jean-Roch; White, Dean; Ulmer, Keith; Wagner, Stephen Robert; Bagby, Linda; Bhat, Pushpalatha C; Burkett, Kevin; Cihangir, Selcuk; Gutsche, Oliver; Jensen, Hans; Johnson, Mark; Luzhetskiy, Nikolay; Mason, David; Miao, Ting; Moccia, Stefano; Noeding, Carsten; Ronzhin, Anatoly; Skup, Ewa; Spalding, William J; Spiegel, Leonard; Tkaczyk, Slawek; Yumiceva, Francisco; Zatserklyaniy, Andriy; Zerev, E; Anghel, Ioana Maria; Bazterra, Victor Eduardo; Gerber, Cecilia Elena; Khalatian, S; Shabalina, Elizaveta; Baringer, Philip; Bean, Alice; Chen, Jie; Hinchey, Carl Louis; Martin, Christophe; Moulik, Tania; Robinson, Richard; Gritsan, Andrei; Lae, Chung Khim; Tran, Nhan Viet; Everaerts, Pieter; Hahn, Kristan Allan; Harris, Philip; Nahn, Steve; Rudolph, Matthew; Sung, Kevin; Betchart, Burton; Demina, Regina; Gotra, Yury; Korjenevski, Sergey; Miner, Daniel Carl; Orbaker, Douglas; Christofek, Leonard; Hooper, Ryan; Landsberg, Greg; Nguyen, Duong; Narain, Meenakshi; Speer, Thomas; Tsang, Ka Vang

    2009-01-01

    In March 2007 the assembly of the Silicon Strip Tracker was completed at the Tracker Integration Facility at CERN. Nearly 15% of the detector was instrumented using cables, fiber optics, power supplies, and electronics intended for the operation at the LHC. A local chiller was used to circulate the coolant for low temperature operation. In order to understand the efficiency and alignment of the strip tracker modules, a cosmic ray trigger was implemented. From March through July 4.5 million triggers were recorded. This period, referred to as the Sector Test, provided practical experience with the operation of the Tracker, especially safety, data acquisition, power, and cooling systems. This paper describes the performance of the strip system during the Sector Test, which consisted of five distinct periods defined by the coolant temperature. Significant emphasis is placed on comparisons between the data and results from Monte Carlo studies.

  17. The analytic structure of trigonometric S-matrices

    International Nuclear Information System (INIS)

    Hollowood, T.J.

    1994-01-01

    S-matrices associated to the vector representations of the quantum groups for the classical Lie algebras are constructed. For the a m-1 and c m algebras the complete S-matrix is found by an application of the bootstrap equations. It is shown that the simplest form for the S-matrix which generalizes that of the Gross-Neveu model is not consistent for the non-simply-laced algebras due to the existence of unexplained singularities on the physical strip. However, a form which generalizes the S-matrix of the principal chiral model is shown to be consistent via an argument which uses a novel application of the Coleman-Thun mechanism. The analysis also gives a correct description of the analytic structure of the S-matrix of the principle chiral model for c m . (orig.)

  18. Deep percolation in greenhouse-cultivated celery using the technique of subsurface film strips placement

    Directory of Open Access Journals (Sweden)

    Zhida Du

    2014-05-01

    Full Text Available To reduce the deep percolation during greenhouse vegetable cultivation, the technique of subsurface film strips placement was tested. Four treatments with two kinds of cross-sections (flat and U-shaped and two different spacings (10 cm and 40 cm of subsurface film strips were arranged in a greenhouse before planting celery. At the same time, a non-film treatment was arranged for comparison. Soil water content was measured and irrigation time was adjusted according to the soil water content. Evapotranspiration of celery during growth was calculated by the method of energy balance and the deep percolation was calculated by the equation of water balance. Deep percolation was reduced in all experimental treatments. Greater reduction in deep percolation was observed when using U-shaped cross-section strips compared with that using the flat cross-section strips. In addition, greater reduction in deep percolation was observed when the spacing between the film strips was smaller. The results of this test showed that the technique of subsurface film strips placement can reduce deep percolation and conserve irrigation water for greenhouse vegetables cultivation. However, the optimal layout variables for the use of the technique of subsurface film strips placement need further experimental and numerical analysis.

  19. Three-dimensional transport theory: An analytical solution of an internal beam searchlight problem-I

    International Nuclear Information System (INIS)

    Williams, M.M.R.

    2009-01-01

    We describe a number of methods for obtaining analytical solutions and numerical results for three-dimensional one-speed neutron transport problems in a half-space containing a variety of source shapes which emit neutrons mono-directionally. For example, we consider an off-centre point source, a ring source and a disk source, or any combination of these, and calculate the surface scalar flux as a function of the radial and angular co-ordinates. Fourier transforms in the transverse directions are used and a Laplace transform in the axial direction. This enables the Wiener-Hopf method to be employed, followed by an inverse Fourier-Hankel transform. Some additional transformations are introduced which enable the inverse Hankel transforms involving Bessel functions to be evaluated numerically more efficiently. A hybrid diffusion theory method is also described which is shown to be a useful guide to the general behaviour of the solutions of the transport equation.

  20. Si-strip photon counting detectors for contrast-enhanced spectral mammography

    Science.gov (United States)

    Chen, Buxin; Reiser, Ingrid; Wessel, Jan C.; Malakhov, Nail; Wawrzyniak, Gregor; Hartsough, Neal E.; Gandhi, Thulasi; Chen, Chin-Tu; Iwanczyk, Jan S.; Barber, William C.

    2015-08-01

    We report on the development of silicon strip detectors for energy-resolved clinical mammography. Typically, X-ray integrating detectors based on scintillating cesium iodide CsI(Tl) or amorphous selenium (a-Se) are used in most commercial systems. Recently, mammography instrumentation has been introduced based on photon counting Si strip detectors. The required performance for mammography in terms of the output count rate, spatial resolution, and dynamic range must be obtained with sufficient field of view for the application, thus requiring the tiling of pixel arrays and particular scanning techniques. Room temperature Si strip detector, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel, provided that the sensors are designed for rapid signal formation across the X-ray energy ranges of the application. We present our methods and results from the optimization of Si-strip detectors for contrast enhanced spectral mammography. We describe the method being developed for quantifying iodine contrast using the energy-resolved detector with fixed thresholds. We demonstrate the feasibility of the method by scanning an iodine phantom with clinically relevant contrast levels.