WorldWideScience

Sample records for strip detectors based

  1. ALICE Silicon Strip Detector

    CERN Multimedia

    Nooren, G

    2013-01-01

    The Silicon Strip Detector (SSD) constitutes the two outermost layers of the Inner Tracking System (ITS) of the ALICE Experiment. The SSD plays a crucial role in the tracking of the particles produced in the collisions connecting the tracks from the external detectors (Time Projection Chamber) to the ITS. The SSD also contributes to the particle identification through the measurement of their energy loss.

  2. Readout of silicon strip detectors

    CERN Document Server

    Dabrowski, W

    2003-01-01

    Various architectural and technological options of readout electronics for silicon strip detectors in vertex and tracking applications are discussed briefly. The ABCD3T ASIC for the readout of silicon strip detectors in the ATLAS semiconductor tracker is presented. The architecture of the chip, some design issues and radiation effects are discussed.

  3. Integrated USB based readout interface for silicon strip detectors of the ATLAS SCT module

    Science.gov (United States)

    Masek, P.; Linhart, V.; Granja, C.; Pospisil, S.; Husak, M.

    2011-12-01

    An integrated portable USB based readout interface for the ATLAS semiconductor trackers (SCT) has been built. The ATLAS SCT modules are large area silicon strip detectors designed for tracking of high-energy charged particles resulting in collisions on Large Hadron Collider (LHC) in CERN. These modules can be also used on small accelerators for medical or industry applications where a compact and configurable readout interface would be useful. A complete custom made PC-host software tool was written for Windows platform for control and DAQ with build-in online visualization. The new constructed interface provides integrated power, control and DAQ and configurable communication between the detector module and the controlling PC. The interface is based on the Field Programmable Gate Array (FPGA) and the high speed USB 2.0 standard. This design permits to operate the modules under high particle fluence while minimizing the dead time of the whole detection system. Utilization of the programmable device simplifies the operation and permits future expansion of the functionality without any hardware changes. The device includes the high voltage source for detector bias up to 500 V and it is equipped with number of devices for monitoring the operation and conditions of measurement (temperature, humidity, voltage). These features are particularly useful as the strip detector must be operated in a well controlled environment. The operation of the interface will be demonstrated on data measured with different particles from radiation sources.

  4. Measurement of characteristic impedance of silicon fiber sheet based readout strip panel for RPC detector in INO

    Science.gov (United States)

    Singh, M. K.; Kumar, A.; Marimuthu, N.; Singh, V.; Subrahmanyam, V. S.

    2017-01-01

    The India-based Neutrino Observatory (INO) is a mega science project of India, which is going to use about 30,000 Resistive Plate Chambers (RPC) as active detector elements for the study of atmoshpheric neutrino oscillations. Each RPC detector will consist of two orthogonally placed readout strip panel for picking the signals generated in the gas chamber. The area of RPC detector in INO-ICAL (Iron Calorimeter) experiment will be 2 m × 2 m, therefore the dimensions of readout strip panel should also be 2 m × 2 m. To get undistorted signals pass through the readout strip panel to front-end electronics, their characteristic impedance should be matched with each other. In the present paper, we describe the need and search of new dielectric material for the fabrication of flame resistant, waterproof and flexible readout strip panel. We will also describe the measurement of characteristic impedance of Plastic Honeycomb (PH) based readout strip panel and Silicon Fiber Sheet (SFS) based readout strip panel in a comparative way, and its variation under loading and with time. Based on this study, we found that a 5 mm thick SFS-based readout strip panel has a minimum signal reflection at 49.5 ohm characteristic impedance value. Our study shows that SFS is a good dielectric material for the purpose.

  5. Development of a Compton camera for medical applications based on silicon strip and scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Krimmer, J., E-mail: j.krimmer@ipnl.in2p3.fr [Institut de Physique Nucléaire de Lyon, Université de Lyon, Université Lyon 1, CNRS/IN2P3 UMR 5822, 69622 Villeurbanne cedex (France); Ley, J.-L. [Institut de Physique Nucléaire de Lyon, Université de Lyon, Université Lyon 1, CNRS/IN2P3 UMR 5822, 69622 Villeurbanne cedex (France); Abellan, C.; Cachemiche, J.-P. [Aix-Marseille Université, CNRS/IN2P3, CPPM UMR 7346, 13288 Marseille (France); Caponetto, L.; Chen, X.; Dahoumane, M.; Dauvergne, D. [Institut de Physique Nucléaire de Lyon, Université de Lyon, Université Lyon 1, CNRS/IN2P3 UMR 5822, 69622 Villeurbanne cedex (France); Freud, N. [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA - Lyon, Université Lyon 1, Centre Léon Bérard (France); Joly, B.; Lambert, D.; Lestand, L. [Clermont Université, Université Blaise Pascal, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, F-63000 Clermont-Ferrand (France); Létang, J.M. [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA - Lyon, Université Lyon 1, Centre Léon Bérard (France); Magne, M. [Clermont Université, Université Blaise Pascal, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, F-63000 Clermont-Ferrand (France); and others

    2015-07-01

    A Compton camera is being developed for the purpose of ion-range monitoring during hadrontherapy via the detection of prompt-gamma rays. The system consists of a scintillating fiber beam tagging hodoscope, a stack of double sided silicon strip detectors (90×90×2 mm{sup 3}, 2×64 strips) as scatter detectors, as well as bismuth germanate (BGO) scintillation detectors (38×35×30 mm{sup 3}, 100 blocks) as absorbers. The individual components will be described, together with the status of their characterization.

  6. Superconducting nano-strip particle detectors

    International Nuclear Information System (INIS)

    Cristiano, R; Ejrnaes, M; Casaburi, A; Zen, N; Ohkubo, M

    2015-01-01

    We review progress in the development and applications of superconducting nano-strip particle detectors. Particle detectors based on superconducting nano-strips stem from the parent devices developed for single photon detection (SSPD) and share with them ultra-fast response times (sub-nanosecond) and the ability to operate at a relatively high temperature (2–5 K) compared with other cryogenic detectors. SSPDs have been used in the detection of electrons, neutral and charged ions, and biological macromolecules; nevertheless, the development of superconducting nano-strip particle detectors has mainly been driven by their use in time-of-flight mass spectrometers (TOF-MSs) where the goal of 100% efficiency at large mass values can be achieved. Special emphasis will be given to this case, reporting on the great progress which has been achieved and which permits us to overcome the limitations of existing mass spectrometers represented by low detection efficiency at large masses and charge/mass ambiguity. Furthermore, such progress could represent a breakthrough in the field. In this review article we will introduce the device concept and detection principle, stressing the peculiarities of the nano-strip particle detector as well as its similarities with photon detectors. The development of parallel strip configuration is introduced and extensively discussed, since it has contributed to the significant progress of TOF-MS applications. (paper)

  7. A digital X-ray imaging system based on silicon strip detectors working in edge-on configuration

    Energy Technology Data Exchange (ETDEWEB)

    Bolanos, L. [CEADEN, Calle 30 502 e/ 5ta y 7ma Avenida, Playa, Ciudad Habana (Cuba); Boscardin, M. [IRST, Fondazione Bruno Kessler, Via Sommarive 18, Povo, 38100 Trento (Italy); Cabal, A.E. [CEADEN, Calle 30 502 e/ 5ta y 7ma Avenida, Playa, Ciudad Habana (Cuba); Diaz, M. [InSTEC, Ave. Salvador Allende esq. Luaces, Quinta de los Molinos, Ciudad Habana (Cuba); Grybos, P.; Maj, P. [Faculty of Electrical Engineering, Automatics, Computer Science and Electronics, Department of Measurement and Instrumentation, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Prino, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Torino, Via P. Giuria 1, 10125 Torino (Italy); Ramello, L. [Dipartimento di Scienze e Tecnologie Avanzate, Universita del Piemonte Orientale, Via T. Michel 11, 15100 Alessandria (Italy)], E-mail: luciano.ramello@mfn.unipmn.it; Szczygiel, R. [Faculty of Electrical Engineering, Automatics, Computer Science and Electronics, Department of Measurement and Instrumentation, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland)

    2009-09-21

    We present the energy resolution and imaging performance of a digital X-ray imaging system based on a 512-strip silicon strip detector (SSD) working in the edge-on configuration. The SSDs tested in the system are 300 {mu}m thick with 1 or 2-cm-long strips and 100 {mu}m pitch. To ensure a very small dead area of the SSD working in edge-on configuration, the detector is cut perpendicular to the strips at a distance of only 20 {mu}m from the end of the strips. The 512-strip silicon detector is read out by eight 64-channel integrated circuits called DEDIX [Grybos et al., IEEE Trans. Nucl. Sci. NS-54 (2007) 1207]. The DEDIX IC operates in a single photon counting mode with two independent amplitude discriminators per channel. The readout electronic channel connected to a detector with effective input capacitance of about 2 pF has an average equivalent noise charge (ENC) of about 163 el. rms and is able to count 1 Mcps of average rate of input pulses. The system consisting of 512 channels has an excellent channel-to-channel uniformity-the effective threshold spread calculated to the charge-sensitive amplifier inputs is 12 el. rms (at one sigma level). With this system a few test images of a phantom have been taken in the 10-30 keV energy range.

  8. Characterization of a dose verification system dedicated to radiotherapy treatments based on a silicon detector multi-strips

    International Nuclear Information System (INIS)

    Bocca, A.; Cortes Giraldo, M. A.; Gallardo, M. I.; Espino, J. M.; Aranas, R.; Abou Haidar, Z.; Alvarez, M. A. G.; Quesada, J. M.; Vega-Leal, A. P.; Perez Neto, F. J.

    2011-01-01

    In this paper, we present the characterization of a silicon detector multi-strips (SSSSD: Single Sided Silicon Strip Detector), developed by the company Micron Semiconductors Ltd. for use as a verification system for radiotherapy treatments.

  9. 3D silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parzefall, Ulrich [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany)], E-mail: ulrich.parzefall@physik.uni-freiburg.de; Bates, Richard [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Boscardin, Maurizio [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Dalla Betta, Gian-Franco [INFN and Universita' di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Eckert, Simon [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Eklund, Lars; Fleta, Celeste [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Jakobs, Karl; Kuehn, Susanne [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Lozano, Manuel [Instituto de Microelectronica de Barcelona, IMB-CNM, CSIC, Barcelona (Spain); Pahn, Gregor [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Parkes, Chris [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Pellegrini, Giulio [Instituto de Microelectronica de Barcelona, IMB-CNM, CSIC, Barcelona (Spain); Pennicard, David [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Piemonte, Claudio; Ronchin, Sabina [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Szumlak, Tomasz [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Zoboli, Andrea [INFN and Universita' di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Zorzi, Nicola [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy)

    2009-06-01

    While the Large Hadron Collider (LHC) at CERN has started operation in autumn 2008, plans for a luminosity upgrade to the Super-LHC (sLHC) have already been developed for several years. This projected luminosity increase by an order of magnitude gives rise to a challenging radiation environment for tracking detectors at the LHC experiments. Significant improvements in radiation hardness are required with respect to the LHC. Using a strawman layout for the new tracker of the ATLAS experiment as an example, silicon strip detectors (SSDs) with short strips of 2-3 cm length are foreseen to cover the region from 28 to 60 cm distance to the beam. These SSD will be exposed to radiation levels up to 10{sup 15}N{sub eq}/cm{sup 2}, which makes radiation resistance a major concern for the upgraded ATLAS tracker. Several approaches to increasing the radiation hardness of silicon detectors exist. In this article, it is proposed to combine the radiation hard 3D-design originally conceived for pixel-style applications with the benefits of the established planar technology for strip detectors by using SSDs that have regularly spaced doped columns extending into the silicon bulk under the detector strips. The first 3D SSDs to become available for testing were made in the Single Type Column (STC) design, a technological simplification of the original 3D design. With such 3D SSDs, a small number of prototype sLHC detector modules with LHC-speed front-end electronics as used in the semiconductor tracking systems of present LHC experiments were built. Modules were tested before and after irradiation to fluences of 10{sup 15}N{sub eq}/cm{sup 2}. The tests were performed with three systems: a highly focused IR-laser with 5{mu}m spot size to make position-resolved scans of the charge collection efficiency, an Sr{sup 90}{beta}-source set-up to measure the signal levels for a minimum ionizing particle (MIP), and a beam test with 180 GeV pions at CERN. This article gives a brief overview of

  10. The charge collection in silicon strip detectors

    International Nuclear Information System (INIS)

    Boehringer, T.; Hubbeling, L.; Weilhammer, P.; Kemmer, J.; Koetz, U.; Riebesell, M.; Belau, E.; Klanner, R.; Lutz, G.; Neugebauer, E.; Seebrunner, H.J.; Wylie, A.

    1983-02-01

    The charge collection in silicon detectors has been studied, by measuring the response to high-energy particles of a 20μm pitch strip detector as a function of applied voltage and magnetic field. The results are well described by a simple model. The model is used to predict the spatial resolution of silicon strip detectors and to propose a detector with optimized spatial resolution. (orig.)

  11. Silicon strip detectors for the LHCb experiment

    OpenAIRE

    Steinkamp, O

    2005-01-01

    The LHCb experiment is a single-arm magnetic spectrometer. Silicon micro-strip detectors are employed in a significant fraction of the tracking system. The Vertex Locator consists of 21 detector stations that operate inside the LHC beam pipe and are separated from the beam vacuum by a thin aluminium foil. The Silicon Tracker is a large-surface silicon micro-strip detector that covers the full acceptance of the experiment in a single tracking station upstream of the spectrometer magnet and the...

  12. Development of floating strip micromegas detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, Jonathan

    2014-04-28

    Micromegas are high-rate capable, high-resolution micro-pattern gaseous detectors. Square meter sized resistive strip Micromegas are foreseen as replacement of the currently used precision tracking detectors in the Small Wheel, which is part of the forward region of the ATLAS muon spectrometer. The replacement is necessary to ensure tracking and triggering performance of the muon spectrometer after the luminosity increase of the Large Hadron Collider beyond its design value of 10{sup 34} cm{sup -2}s{sup -1} around 2020. In this thesis a novel discharge tolerant floating strip Micromegas detector is presented and described. By individually powering copper anode strips, the effects of a discharge are confined to a small region of the detector. This reduces the impact of discharges on the efficiency by three orders of magnitude, compared to a standard Micromegas. The physics of the detector is studied and discussed in detail. Several detectors are developed: A 6.4 x 6.4 cm{sup 2} floating strip Micromegas with exchangeable SMD capacitors and resistors allows for an optimization of the floating strip principle. The discharge behavior is investigated on this device in depth. The microscopic structure of discharges is quantitatively explained by a detailed detector simulation. A 48 x 50 cm{sup 2} floating strip Micromegas is studied in high energy pion beams. Its homogeneity with respect to pulse height, efficiency and spatial resolution is investigated. The good performance in high-rate background environments is demonstrated in cosmic muon tracking measurements with a 6.4 x 6.4 cm{sup 2} floating strip Micromegas under lateral irradiation with 550 kHz 20 MeV proton beams. A floating strip Micromegas doublet with low material budget is developed for ion tracking without limitations from multiple scattering in imaging applications during medical ion therapy. Highly efficient tracking of 20 MeV protons at particle rates of 550 kHz is possible. The reconstruction of the

  13. LabVIEW-based control and acquisition system for the dosimetric characterization of a silicon strip detector

    Science.gov (United States)

    Ovejero, M. C.; Pérez Vega-Leal, A.; Gallardo, M. I.; Espino, J. M.; Selva, A.; Cortés-Giraldo, M. A.; Arráns, R.

    2017-02-01

    The aim of this work is to present a new data acquisition, control, and analysis software system written in LabVIEW. This system has been designed to obtain the dosimetry of a silicon strip detector in polyethylene. It allows the full automation of the experiments and data analysis required for the dosimetric characterization of silicon detectors. It becomes a useful tool that can be applied in the daily routine check of a beam accelerator.

  14. Prototype Strip Barrel Modules for the ATLAS ITk Strip Detector

    CERN Document Server

    Sawyer, Craig; The ATLAS collaboration

    2017-01-01

    The module design for the Phase II Upgrade of the new ATLAS Inner Tracker (ITk) detector at the LHC employs integrated low mass assembly using single-sided flexible circuits with readout ASICs and a powering circuit incorporating control and monitoring of HV, LV and temperature on the module. Both readout and powering circuits are glued directly onto the silicon sensor surface resulting in a fully integrated, extremely low radiation length module which simultaneously reduces the material requirements of the local support structure by allowing a reduced width stave structure to be employed. Such a module concept has now been fully demonstrated using so-called ABC130 and HCC130 ASICs fabricated in 130nm CMOS technology to readout ATLAS12 n+-in-p silicon strip sensors. Low voltage powering for these demonstrator modules has been realised by utilising a DCDC powerboard based around the CERN FEAST ASIC. This powerboard incorporates an HV multiplexing switch based on a Panasonic GaN transistor. Control and monitori...

  15. System Electronics for the ATLAS Upgraded Strip Detector

    CERN Document Server

    Affolder, T; The ATLAS collaboration; Clark, A; Dabrowskic, W; Dewitt, J; Diez Cornell, S; Dressdant, N; Fadeyev, V; Farthouat, P; Ferrere, D; Greenall, A; Grillo, A; Kaplon, J; Key-Charriere, M; La Marra, D; Lipeles, E; Lynn, D; Newcomer, M; Pereirab, F; Phillips, P; Spencer, E; Swientekc, K; Warren, M; Weidberg, A

    2013-01-01

    The basic concept of the front-end system of the Silicon Strip Detector in the Atlas Detector upgraded for the HL-LHC is being elaborated and proposed. The readout electronics of this new detector is based on front-end chips (ABC130), Hybrid Controller chips (HCC) and End of Stave Controller chips (EOSC). This document defines the basic functionality of the front-end system and of the different ASICs.

  16. Superconducting strip detectors as position sensitive particle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Scherschel, M. (Lab. fuer Festkoerperphysik, ETH-Hoenggerberg, Zuerich (Switzerland) Paul Scherrer Inst., Solid State Div., Villigen (Switzerland)); Finkbeiner, F. (Paul Scherrer Inst., Solid State Div., Villigen (Switzerland)); Zhao, S.P. (Paul Scherrer Inst., Solid State Div., Villigen (Switzerland)); Jaggi, A. (Paul Scherrer Inst., Solid State Div., Villigen (Switzerland)); Maier, T. (Paul Scherrer Inst., Solid State Div., Villigen (Switzerland)); Lerch, P. (Paul Scherrer Inst., Solid State Div., Villigen (Switzerland)); Zehnder, A. (Paul Scherrer Inst., Solid State Div., Villigen (Switzerland)); Ott, H.R. (Lab. fuer Festkoerperphysik, ETH-Hoenggerberg, Zuerich (Switzerland) Paul Scherrer Inst., Solid State Div., Villigen (Switzerland))

    1994-02-01

    The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

  17. Nanoparticle-Based Immunochromatographic Test Strip with Fluorescent Detector for Quantification of Phosphorylated Acetycholinesterase: An Exposure Biomarker of Organophosphorous Agents

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Weiying; Ge, Xiaoxiao; Tang, Yong; Du, Dan; Liu, Deli; Lin, Yuehe

    2013-09-21

    A nanoparticle-based fluorescence immunochromatographic test strip (FITS) coupled with a hand-held detector for highly selective and sensitive detection of phosphorylated acetylcholinesterase (AChE), an exposure biomarker of organophosphate (OP) pesticides and nerve agents, is reported. In this approach, OP-AChE adducts were selectively captured by quantum dot-tagged anti-AChE antibodies (Qdot-anti-AChE) and zirconia nanoparticles (ZrO2 NPs). The sandwich-like immunoreactions were performed among the Qdot-anti-AChE, OP-AChE and ZrO2 NPs to form Qdot-anti-AChE/OP-AChE/ZrO2 complex, which was detected by recording the fluorescence intensity of Qdot captured on the test line. Paraoxon was used as the model OP pesticides. Under optimal conditions, this portable FITS immunosensor demonstrates a highly linear absorption response over the range of 0.01 nM to 10 nM OP-AChE, with a detection limit of 4 pM, coupled with a good reproducibility. Moreover, the FITS immunosensor has been validated with OP-AChE spiked human plasma samples. This is the first report on the development of ZrO2 NPs-based FITS for detection of OP-AChE adduct. The FITS immunosensor provides a sensitive and low-cost sensing platform for on-site screening/evaluating OP pesticides and nerve agents poisoning.

  18. MUST: A silicon strip detector array for radioactive beam experiments

    CERN Document Server

    Blumenfeld, Y; Sauvestre, J E; Maréchal, F; Ottini, S; Alamanos, N; Barbier, A; Beaumel, D; Bonnereau, B; Charlet, D; Clavelin, J F; Courtat, P; Delbourgo-Salvador, P; Douet, R; Engrand, M; Ethvignot, T; Gillibert, A; Khan, E; Lapoux, V; Lagoyannis, A; Lavergne, L; Lebon, S; Lelong, P; Lesage, A; Le Ven, V; Lhenry, I; Martin, J M; Musumarra, A; Pita, S; Petizon, L; Pollacco, E; Pouthas, J; Richard, A; Rougier, D; Santonocito, D; Scarpaci, J A; Sida, J L; Soulet, C; Stutzmann, J S; Suomijärvi, T; Szmigiel, M; Volkov, P; Voltolini, G

    1999-01-01

    A new and innovative array, MUST, based on silicon strip technology and dedicated to the study of reactions induced by radioactive beams on light particles is described. The detector consists of 8 silicon strip - Si(Li) telescopes used to identify recoiling light charged particles through time of flight, energy loss and energy measurements and to determine precisely their scattering angle through X, Y position measurements. Each 60x60 mm sup 2 double sided silicon strip detector with 60 vertical and 60 horizontal strips yields an X-Y position resolution of 1 mm, an energy resolution of 50 keV, a time resolution of around 1 ns and a 500 keV energy threshold for protons. The backing Si(Li) detectors stop protons up to 25 MeV with a resolution of approximately 50 keV. CsI crystals read out by photo-diodes which stop protons up to 70 MeV are added to the telescopes for applications where higher energy particles need to be detected. The dedicated electronics in VXIbus standard allow us to house the 968 logic and a...

  19. Synchrotron applications of pixel and strip detectors at Diamond Light Source

    International Nuclear Information System (INIS)

    Marchal, J.; Tartoni, N.; Nave, C.

    2009-01-01

    A wide range of position-sensitive X-ray detectors have been commissioned on the synchrotron X-ray beamlines operating at the Diamond Light Source in UK. In addition to mature technologies such as image-plates, CCD-based detectors, multi-wire and micro-strip gas detectors, more recent detectors based on semiconductor pixel or strip sensors coupled to CMOS read-out chips are also in use for routine synchrotron X-ray diffraction and scattering experiments. The performance of several commercial and developmental pixel/strip detectors for synchrotron studies are discussed with emphasis on the image quality achieved with these devices. Examples of pixel or strip detector applications at Diamond Light Source as well as the status of the commissioning of these detectors on the beamlines are presented. Finally, priorities and ideas for future developments are discussed.

  20. Digital autoradiography using silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Overdick, M.

    1998-05-01

    Spatially resolving radiation detection systems operating in real time can be used to acquire autoradiographic images. An overview over alternatives to traditional autoradiography is given and the special features of these filmless methods are discussed. On this basis the design of a system for digital autoradiography using silicon strip detectors is presented. Special emphasis is put on the physical background of the detection process in the semiconductor and on the self-triggering read-out technique. The practical performance of the system is analyzed with respect to energy and spatial resolution. This analysis is complemented by case studies from cell biology (especially electrophoresis), botany and mineralogy. Also the results from a time-resolved autoradiographic experiment are presented. (orig.) 80 refs.

  1. Silicon strip detectors for the ATLAS upgrade

    CERN Document Server

    Gonzalez Sevilla, S; The ATLAS collaboration

    2011-01-01

    The Large Hadron Collider at CERN will extend its current physics program by increasing the peak luminosity by one order of magnitude. For ATLAS, one of the two general-purpose experiments of the LHC, an upgrade scenario will imply the complete replacement of its internal tracker due to the harsh conditions in terms of particle rates and radiation doses. New radiation-hard prototype n-in-p silicon sensors have been produced for the short-strip region of the future ATLAS tracker. The sensors have been irradiated up to the fluences expected in the high-luminous LHC collider. This paper summarizes recent results on the performance of the irradiated n-in-p detectors.

  2. Strip type radiation detector and method of making same

    International Nuclear Information System (INIS)

    Jantsch, O.; Feigt, I.; Willig, W.R.

    1976-01-01

    An improved strip detector and a method for making such a detector in which a high resistivity N conduction semiconductor body has electrode strips formed thereon by diffusion is described. The strips are formed so as to be covered by an oxide layer at the surface point of the PN junction and in which the opposite side of the semiconductor body then has a substantial amount of material etched away to form a thin semiconductor upon which strip electrodes which are perpendicular to the electrodes on the first side are then placed

  3. MUST: A silicon strip detector array for radioactive beam experiments

    International Nuclear Information System (INIS)

    Blumenfeld, Y.; Auger, F.; Sauvestre, J.E.; Marechal, F.; Ottini, S.; Alamanos, N.; Barbier, A.; Beaumel, D.; Bonnereau, B.; Charlet, D.; Clavelin, J.F.; Courtat, P.; Delbourgo-Salvador, P.; Douet, R.; Engrand, M.; Ethvignot, T.; Gillibert, A.; Khan, E.; Lapoux, V.; Lagoyannis, A.; Lavergne, L.; Lebon, S.; Lelong, P.; Lesage, A.; Le Ven, V.; Lhenry, I.; Martin, J.M.; Musumarra, A.; Pita, S.; Petizon, L.; Pollacco, E.; Pouthas, J.; Richard, A.; Rougier, D.; Santonocito, D.; Scarpaci, J.A.; Sida, J.L.; Soulet, C.; Stutzmann, J.S.; Suomijaervi, T.; Szmigiel, M.; Volkov, P.; Voltolini, G.

    1999-01-01

    A new and innovative array, MUST, based on silicon strip technology and dedicated to the study of reactions induced by radioactive beams on light particles is described. The detector consists of 8 silicon strip - Si(Li) telescopes used to identify recoiling light charged particles through time of flight, energy loss and energy measurements and to determine precisely their scattering angle through X, Y position measurements. Each 60x60 mm 2 double sided silicon strip detector with 60 vertical and 60 horizontal strips yields an X-Y position resolution of 1 mm, an energy resolution of 50 keV, a time resolution of around 1 ns and a 500 keV energy threshold for protons. The backing Si(Li) detectors stop protons up to 25 MeV with a resolution of approximately 50 keV. CsI crystals read out by photo-diodes which stop protons up to 70 MeV are added to the telescopes for applications where higher energy particles need to be detected. The dedicated electronics in VXIbus standard allow us to house the 968 logic and analog channels of the array in one crate placed adjacent to the reaction chamber and fully remote controlled, including pulse visualization on oscilloscopes. A stand alone data acquisition system devoted to the MUST array has been developed. Isotope identification of light charged particles over the full energy range has been achieved, and the capability of the system to measure angular distributions of states populated in inverse kinematics reactions has been demonstrated

  4. Silicon Strip Detectors for ATLAS at the HL-LHC Upgrade

    CERN Document Server

    Hara, K; The ATLAS collaboration

    2012-01-01

    The present ATLAS silicon strip (SCT) and transition radiation (TRT) trackers will be replaced with new silicon strip detectors, as part of the Inner Tracker System (ITK), for the Phase-2 upgrade of the Large Hadron Collider, HL-LHC. We have carried out intensive R&D programs to establish radiation harder strip detectors that can survive in a radiation level up to 3000 fb-1 of integrated luminosity based on n+-on-p microstrip detector. We describe main specifications for this year’s sensor fabrication, followed by a description of possible module integration schema

  5. Quality Tests of Double-Sided Silicon Strip Detectors

    CERN Document Server

    Cambon, T; CERN. Geneva; Fintz, P; Guillaume, G; Jundt, F; Kuhn, C; Lutz, Jean Robert; Pagès, P; Pozdniakov, S; Rami, F; Sparavec, K; Dulinski, W; Arnold, L

    1997-01-01

    The quality of the SiO2 insulator (AC coupling between metal and implanted strips) of double-sided Silicon strip detectors has been studied by using a probe station. Some tests performed on 23 wafers are described and the results are discussed. Remark This note seems to cause problems with ghostview but it can be printed without any problem.

  6. An efficient, FPGA-based, cluster detection algorithm implementation for a strip detector readout system in a Time Projection Chamber polarimeter

    Science.gov (United States)

    Gregory, Kyle J.; Hill, Joanne E.; Black, J. Kevin; Baumgartner, Wayne H.; Jahoda, Keith

    2016-05-01

    A fundamental challenge in a spaceborne application of a gas-based Time Projection Chamber (TPC) for observation of X-ray polarization is handling the large amount of data collected. The TPC polarimeter described uses the APV-25 Application Specific Integrated Circuit (ASIC) to readout a strip detector. Two dimensional photo- electron track images are created with a time projection technique and used to determine the polarization of the incident X-rays. The detector produces a 128x30 pixel image per photon interaction with each pixel registering 12 bits of collected charge. This creates challenging requirements for data storage and downlink bandwidth with only a modest incidence of photons and can have a significant impact on the overall mission cost. An approach is described for locating and isolating the photoelectron track within the detector image, yielding a much smaller data product, typically between 8x8 pixels and 20x20 pixels. This approach is implemented using a Microsemi RT-ProASIC3-3000 Field-Programmable Gate Array (FPGA), clocked at 20 MHz and utilizing 10.7k logic gates (14% of FPGA), 20 Block RAMs (17% of FPGA), and no external RAM. Results will be presented, demonstrating successful photoelectron track cluster detection with minimal impact to detector dead-time.

  7. Modeling and simulation of Positron Emission Mammography (PEM) based on double-sided CdTe strip detectors

    OpenAIRE

    Özşahin, İlker; Ünlü, Mehmet Zübeyir

    2014-01-01

    Breast cancer is the most common leading cause of cancer death among women. Positron Emission Tomography (PET) Mammography, also known as Positron Emission Mammography (PEM), is a method for imaging primary breast cancer. Over the past few years, PEMs based on scintillation crystals dramatically increased their importance in diagnosis and treatment of early stage breast cancer. However, these detectors have significant limitations like poor energy resolution resulting with false-negative resu...

  8. Efficiency measurements for 3D silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parzefall, Ulrich, E-mail: ulrich.parzefall@physik.uni-freiburg.d [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Dalla Betta, Gian-Franco [INFN Trento and Universita di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Boscardin, Maurizio [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Eckert, Simon [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Eklund, Lars; Fleta, Celeste [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Jakobs, Karl; Koehler, Michael; Kuehn, Susanne; Pahn, Gregor [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Parkes, Chris; Pennicard, David [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Ronchin, Sabina [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Zoboli, Andrea [INFN Trento and Universita di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Zorzi, Nicola [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy)

    2010-11-01

    Silicon strip detectors are widely used as part of the inner tracking layers in particle physics experiments. For applications at the luminosity upgrade of the Large Hadron Collider (LHC), the sLHC, silicon detectors with extreme radiation hardness are required. The 3D detector design, where electrodes are processed from underneath the strips into the silicon bulk material, provides a way to enhance the radiation tolerance of standard planar silicon strip detectors. Detectors with several innovative 3D designs that constitute a simpler and more cost-effective processing than the 3D design initially proposed were connected to read-out electronics from LHC experiments and subsequently tested. Results on the amount of charge collected, the noise and the uniformity of charge collection are given.

  9. A new strips tracker for the upgraded ATLAS ITk detector

    Science.gov (United States)

    David, C.

    2018-01-01

    The ATLAS detector has been designed and developed to function in the environment of the present Large Hadron Collider (LHC). At the next-generation tracking detector proposed for the High Luminosity LHC (HL-LHC), the so-called ATLAS Phase-II Upgrade, the fluences and radiation levels will be higher by as much as a factor of ten. The new sub-detectors must thus be faster, of larger area, more segmented and more radiation hard while the amount of inactive material should be minimized and the power supply to the front-end systems should be increased. For those reasons, the current inner tracker of the ATLAS detector will be fully replaced by an all-silicon tracking system that consists of a pixel detector at small radius close to the beam line and a large area strip tracker surrounding it. This document gives an overview of the design of the strip inner tracker (Strip ITk) and summarises the intensive R&D activities performed over the last years by the numerous institutes within the Strips ITk collaboration. These studies are accompanied with a strong prototyping effort to contribute to the optimisation of the Strip ITk's structure and components. This effort culminated recently in the release of the ATLAS Strips ITk Technical Design Report (TDR).

  10. Impact of radiation on breakdown performance of Si strip detectors

    CERN Document Server

    Bhardwaj, A; Chatterji, S; Ranjan, Kirti; Shivpuri, E K; Srivastava-Ajay, K

    2002-01-01

    The very intense radiation environment of high luminosity future colliding beam experiments, like Large Hadron Collider (LHC etc.) makes radiation hardness the most urgent demand for Si detectors. The radiation hardness of Si strip detectors especially developed for LHC experiment was investigated with respect to ionizing and nonionizing radiation using computer simulations. (10 refs).

  11. Development, prototyping and characterization of double sided silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Topkar, Anita, E-mail: anita@barc.gov.in; Singh, Arvind; Aggarwal, Bharti; Kumar, Amit; Kumar, Arvind; Murali Krishna, L.V.; Das, D.

    2016-10-21

    Double sided DC-coupled silicon strip detectors with geometry of 65 mm×65 mm have been developed in India for nuclear physics experiments. The detectors have 64 P{sup +} strips on the front side and 64 N{sup +} strips on the backside with a pitch of 0.9 mm. These detectors were fabricated using a twelve mask layer process involving double sided wafer processing technology. Semiconductor process and device simulations were carried out in order to theoretically estimate the impact of important design and process parameters on the breakdown voltage of detectors. The performance of the first lot of prototype detectors has been studied using static characterization tests and using an alpha source. The characterization results demonstrate that the detectors have low leakage currents and good uniformity over the detector area of about 40 cm{sup 2}. Overview of the detector design, fabrication process, simulation results and initial characterization results of the detectors are presented in this paper.

  12. The New Silicon Strip Detectors for the CMS Tracker Upgrade

    CERN Document Server

    Dragicevic, Marko

    2010-01-01

    The first introductory part of the thesis describes the concept of the CMS experiment. The tasks of the various detector systems and their technical implementations in CMS are explained. To facilitate the understanding of the basic principles of silicon strip sensors, the subsequent chapter discusses the fundamentals in semiconductor technology, with particular emphasis on silicon. The necessary process steps to manufacture strip sensors in a so-called planar process are described in detail. Furthermore, the effects of irradiation on silicon strip sensors are discussed. To conclude the introductory part of the thesis, the design of the silicon strip sensors of the CMS Tracker are described in detail. The choice of the substrate material and the complex geometry of the sensors are reviewed and the quality assurance procedures for the production of the sensors are presented. Furthermore the design of the detector modules are described. The main part of this thesis starts with a discussion on the demands on the ...

  13. Silicon strip detectors for the ATLAS HL-LHC upgrade

    CERN Document Server

    Gonzalez Sevilla, S; The ATLAS collaboration

    2011-01-01

    The LHC upgrade is foreseen to increase the ATLAS design luminosity by a factor ten, implying the need to build a new tracker suited to the harsh HL-LHC conditions in terms of particle rates and radiation doses. In order to cope with the increase in pile-up backgrounds at the higher luminosity, an all silicon detector is being designed. To successfully face the increased radiation dose, a new generation of extremely radiation hard silicon detectors is being designed. We give an overview of the ATLAS tracker upgrade project, in particular focusing on the crucial innermost silicon strip layers. Results from a wide range of irradiated silicon detectors for the strip region of the future ATLAS tracker are presented. Layout concepts for lightweight yet mechanically very rigid detector modules with high service integration are shown.

  14. Parallel superconducting strip-line detectors: reset behaviour in the single-strip switch regime

    International Nuclear Information System (INIS)

    Casaburi, A; Heath, R M; Tanner, M G; Hadfield, R H; Cristiano, R; Ejrnaes, M; Nappi, C

    2014-01-01

    Superconducting strip-line detectors (SSLDs) are an important emerging technology for the detection of single molecules in time-of-flight mass spectrometry (TOF-MS). We present an experimental investigation of a SSLD laid out in a parallel configuration, designed to address selected single strip-lines operating in the single-strip switch regime. Fast laser pulses were tightly focused onto the device, allowing controllable nucleation of a resistive region at a specific location and study of the subsequent device response dynamics. We observed that in this regime, although the strip-line returns to the superconducting state after triggering, no effective recovery of the bias current occurs, in qualitative agreement with a phenomenological circuit simulation that we performed. Moreover, from theoretical considerations and by looking at the experimental pulse amplitude distribution histogram, we have the first confirmation of the fact that the phenomenological London model governs the current redistribution in these large area devices also after detection events. (paper)

  15. Parallel superconducting strip-line detectors: reset behaviour in the single-strip switch regime

    Science.gov (United States)

    Casaburi, A.; Heath, R. M.; Tanner, M. G.; Cristiano, R.; Ejrnaes, M.; Nappi, C.; Hadfield, R. H.

    2014-04-01

    Superconducting strip-line detectors (SSLDs) are an important emerging technology for the detection of single molecules in time-of-flight mass spectrometry (TOF-MS). We present an experimental investigation of a SSLD laid out in a parallel configuration, designed to address selected single strip-lines operating in the single-strip switch regime. Fast laser pulses were tightly focused onto the device, allowing controllable nucleation of a resistive region at a specific location and study of the subsequent device response dynamics. We observed that in this regime, although the strip-line returns to the superconducting state after triggering, no effective recovery of the bias current occurs, in qualitative agreement with a phenomenological circuit simulation that we performed. Moreover, from theoretical considerations and by looking at the experimental pulse amplitude distribution histogram, we have the first confirmation of the fact that the phenomenological London model governs the current redistribution in these large area devices also after detection events.

  16. Digital Images of Breast Biopsies using a Silicon Strip Detector

    International Nuclear Information System (INIS)

    Montano, Luis M.; Diaz, Claudia C.; Leyva, Antonio; Cabal, Fatima; Ortiz, Carlos M.

    2006-01-01

    In our study we have used a silicon strip detector to obtain digital images of some breast tissues with micro calcifications. Some of those images will be shown and we will discuss the perspectives of using this technique as an improvement of breast cancer diagnostics

  17. Development of the H1 backward silicon strip detector

    International Nuclear Information System (INIS)

    Eick, W.; Hansen, K.; Lange, W.; Prell, S.; Zimmermann, W.; Bullough, M.A.; Greenwood, N.M.; Lucas, A.D.; Newton, A.M.; Wilburn, C.D.; Horisberger, R.; Pitzl, D.; Haynes, W.J.; Noyes, G.

    1996-10-01

    The development and first results are described of a silicon strip detector telescope for the HERA experiment H1 designed to measure the polar angle of deep inelastic scattered electrons at small Bjorken x and low momentum transfers Q 2 . (orig.)

  18. Operational issues of present ATLAS strip detector

    CERN Document Server

    Yacoob, S; The ATLAS collaboration

    2013-01-01

    Current results from the successful operation of the Semi-Conductor Tracker (SCT) Detector at the LHC and its status after three years of operation is presented. This note reports on the operation of the detector including an overview of the issues we encountered and the observation of significant increases in leakage currents from bulk damage due to non-ionising radiation, there have been a small number of significant changes effecting detector operation since the contribution to the previous conference in the series [1]. The main emphasis is given to the tracking performance of the SCT and the data quality during the many months of data-taking (the LHC delivered 47 pb

  19. Evaluation of silicon micro strip detectors with large read-out pitch

    International Nuclear Information System (INIS)

    Senyo, K.; Yamamura, K.; Tsuboyama, T.; Avrillon, S.; Asano, Y.; Bozek, A.; Natkaniec, Z.; Palka, H.; Rozanska, M.; Rybicki, K.

    1996-01-01

    For the development of the silicon micro-strip detector with the pitch of the readout strips as large as 250 μm on the ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips. (orig.)

  20. Performance of the ATLAS silicon strip detector modules

    International Nuclear Information System (INIS)

    Albiol, F.; Ballester, F.

    1998-01-01

    The performance of the silicon strip detector prototypes developed for use in ATLAS at the LHC is reported. Baseline detector assemblies (''modules'') of 12 cm length were read out with binary electronics at 40 MHz clock speed. For both irradiated and unirradiated modules, the tracking efficiency, noise occupancy, and position resolution were measured as a function of bias voltage, binary hit threshold, and detector rotation angle in a 1.56 T magnetic field. Measurements were also performed at a particle flux comparable to the one expected at the LHC. (orig.)

  1. ATLAS ITk Strip Detector for High-Luminosity LHC

    CERN Document Server

    Kroll, Jiri; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment is currently preparing for an upgrade of the tracking system in the course of the High-Luminosity LHC that is scheduled for 2026. The expected peak instantaneous luminosity up to 7.5E34 per second and cm2 corresponding to approximately 200 inelastic proton-proton interactions per beam crossing, radiation damage at an integrated luminosity of 3000/fb and hadron fluencies over 1E16 1 MeV neutron equivalent per cm2, as well as fast hardware tracking capability that will bring Level-0 trigger rate of a few MHz down to a Level-1 trigger rate below 1 MHz require a replacement of existing Inner Detector by an all-silicon Inner Tracker (ITk) with a pixel detector surrounded by a strip detector. The current prototyping phase, that is working with ITk Strip Detector consisting of a four-layer barrel and a forward region composed of six discs on each side of the barrel, has resulted in the ATLAS ITk Strip Detector Technical Design Report (TDR), which starts the pre-production readiness phase at the ...

  2. ATLAS ITk Strip Detector for High-Luminosity LHC

    CERN Document Server

    Kroll, Jiri; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment is currently preparing for an upgrade of the tracking system in the course of the High-Luminosity LHC that is scheduled for 2026. The expected peak instantaneous luminosity up to $7.5\\times10^{34}\\;\\mathrm{cm}^{-2}\\mathrm{s}^{-1}$ corresponding to approximately 200 inelastic proton-proton interactions per beam crossing, radiation damage at an integrated luminosity of $3000\\;\\mathrm{fb}^{-1}$ and hadron fluencies over $2\\times10^{16}\\;\\mathrm{n}_{\\mathrm{eq}}/\\mathrm{cm}^{2}$, as well as fast hardware tracking capability that will bring Level-0 trigger rate of a few MHz down to a Level-1 trigger rate below 1 MHz require a replacement of existing Inner Detector by an all-silicon Inner Tracker with a pixel detector surrounded by a strip detector. The current prototyping phase, that is working with ITk Strip Detector consisting of a four-layer barrel and a forward region composed of six disks on each side of the barrel, has resulted in the ATLAS Inner Tracker Strip Detector Technical Design R...

  3. Characterization of a dose verification system dedicated to radiotherapy treatments based on a silicon detector multi-strips; Caracterizacion de un sistema de verificacion de dosis dedicado a tratamientos de radioterapia basado en un detector de silicio de multi-tiras

    Energy Technology Data Exchange (ETDEWEB)

    Bocca, A.; Cortes Giraldo, M. A.; Gallardo, M. I.; Espino, J. M.; Aranas, R.; Abou Haidar, Z.; Alvarez, M. A. G.; Quesada, J. M.; Vega-Leal, A. P.; Perez Neto, F. J.

    2011-07-01

    In this paper, we present the characterization of a silicon detector multi-strips (SSSSD: Single Sided Silicon Strip Detector), developed by the company Micron Semiconductors Ltd. for use as a verification system for radiotherapy treatments.

  4. Strip Detector for the ATLAS Detector Upgrade for the High-Luminosity LHC

    CERN Document Server

    Sperlich, Dennis; The ATLAS collaboration

    2016-01-01

    The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential of the LHC through a sizeable increase in the luminosity, reaching 1*10^35 cm2s-1 after 10 years of operation. A consequence of this increased luminosity is the expected radiation damage at an integrated luminosity of 3000/fb, requiring the tracking detectors to withstand hadron fluencies to over 1*10^16 1 MeV neutron equivalent per cm2. With the addition of increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk), which will consist of both strip and pixelated silicon detectors. The physics motivations, required performance characteristics and basic design of the proposed upgrade of the strip detector will be a subject of this talk. Present ideas and solutions for the strip detector and current research and development program will be discussed.

  5. Strip Detector for the ATLAS Detector Upgrade for the High - Luminosity LHC

    CERN Document Server

    Sperlich, Dennis; The ATLAS collaboration

    2016-01-01

    The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential of the LHC through a sizeable increase in the luminosity, reaching 1*10^35 cm2s-1 after 10 years of operation. A consequence of this increased luminosity is the expected radiation damage at an integrated luminosity of 3000/fb, requiring the tracking detectors to withstand hadron fluencies to over 1*10^16 1 MeV neutron equivalent per cm2. With the addition of increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk), which will consist of both strip and pixelated silicon detectors. The physics motivations, required performance characteristics and basic design of the proposed upgrade of the strip detector will be a subject of this talk. Present ideas and solutions for the strip detector and current research and development program will be discussed.

  6. Beam test of CSES silicon strip detector module

    Science.gov (United States)

    Zhang, Da-Li; Lu, Hong; Wang, Huan-Yu; Li, Xin-Qiao; Xu, Yan-Bing; An, Zheng-Hua; Yu, Xiao-xia; Wang, Hui; Shi, Feng; Wang, Ping; Zhao, Xiao-Yun

    2017-05-01

    The silicon-strip tracker of the China Seismo-Electromagnetic Satellite (CSES) consists of two double-sided silicon strip detectors (DSSDs) which provide incident particle tracking information. A low-noise analog ASIC VA140 was used in this study for DSSD signal readout. A beam test on the DSSD module was performed at the Beijing Test Beam Facility of the Beijing Electron Positron Collider (BEPC) using a 400-800 MeV/c proton beam. The pedestal analysis results, RMSE noise, gain correction, and intensity distribution of incident particles of the DSSD module are presented. Supported by the XXX Civil Space Programme

  7. Silicon Strip Detectors for ATLAS at the HL-LHC Upgrade

    CERN Document Server

    Hara, K; The ATLAS collaboration

    2012-01-01

    present ATLAS silicon strip tracker (SCT) and transition radiation tracker(TRT) are to be replaced with new silicon strip detectors as part of the Inner Tracker System (ITK) for the Phase-II upgrade of the Large Hadron Collider, HL-LHC. We have carried out intensive R&D programs based on n+-on-p microstrip detectors to fabricate improved radiation hard strip detectors that can survive the radiation levels corresponding to the integrated luminosity of up to 3000 fb−1. We describe the main specifications for this year’s sensor fabrication and the related R&D results, followed by a description of the candidate schema for module integration.

  8. Technology Development on P-type Silicon Strip Detectors for Proton Beam Dosimetry

    International Nuclear Information System (INIS)

    Aouadi, K.; Bouterfa, M.; Delamare, R.; Flandre, D.; Bertrand, D.; Henry, F.

    2013-06-01

    In this paper, we present a technology for the fabrication of n-in-p silicon strip detectors, which is based on the use of Al 2 O 3 oxide compared to p-spray insulation scheme. This technology has been developed using the best technological parameters deduced from simulations, particularly for the p-spray implantation parameters. Different wafers were processed towards the fabrication of the radiation detectors with p-spray insulation and Al 2 O 3 . The evaluation of the prototype detectors has been carried out by performing the electrical characterization of the devices through the measurement of current-voltage and capacitance-voltage characteristics, as well as the measurement of detection response under radiation. The results of electrical measurements indicate that detectors fabricated with Al 2 O 3 exhibit a dark current several times lower than p-spray detectors and show an excellent electrical insulation between strips with a higher inter-strip resistance. Response of Al 2 O 3 strip detector under radiation has been found better. The resulting improved output signal dynamic range finally makes the use of Al 2 O 3 more attractive. (authors)

  9. The ATLAS Tracker Upgrade: Short Strips Detectors for the SLHC

    CERN Document Server

    Soldevila, U; Lacasta, C; Marti i García, S; Miñano, M

    2009-01-01

    It is foreseen to increase the luminosity of the Large Hadron Collider (LHC) at CERN around 2018 by about an order of magnitude, with the upgraded machine dubbed Super-LHC or sLHC. The ATLAS experiment will require a new tracker for SLHC operation. In order to cope with the order of magnitude increase in pile-up backgrounds at the higher luminosity, an all silicon detector is being designed. The new strip detector will use significantly shorter strips than the current SCT in order to minimise the occupancy. As the increased luminosity will mean a corresponding increase in radiation dose, a new generation of extremely radiation hard silicon detectors is required. A massive R&D programme is underway to develop silicon sensors with sufficient radiation hardness. New front-end electronics and readout systems are being designed to cope with the higher data rates. The challenges of powering and cooling a very large strip detector will be discussed. Ideas on possible schemes for the layout and support mechanics ...

  10. Effects of the interstrip gap on the efficiency and response of Double Sided Silicon Strip Detectors

    Directory of Open Access Journals (Sweden)

    Torresi D.

    2016-01-01

    Full Text Available In this work the effects of the segmentation of the electrodes of Double Sided Silicon Strip Detectors (DSSSDs are investigated. In order to characterize the response of the DSSSDs we perform a first experiment by using tandem beams of different energies directly sent on the detector and a second experiment by mean of a proton microbeam. Results show that the effective width of the inter-strip region and the efficiency for full energy detection, varies with both detected energy and bias voltage. The experimental results are qualitatively reproduced by a simplified model based on the Shockley-Ramo-Gunn framework.

  11. Strip detector for the ATLAS detector upgrade for the High-Luminosity LHC

    CERN Document Server

    Veloce, Laurelle Maria; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment is currently preparing for an upgrade of the tracking system in the course of the High Luminosity LHC, scheduled for 2025. The expected radiation damage at an integrated luminosity of 3000fb-1 will require the tracking detectors to withstand hadron fluencies to over 1x1016 1 MeV neutron equivalent per cm2. With the addition of increased readout rates, the existing Inner Detector will have to be replaced by an all-silicon Inner Tracker (ITk) with a pixel detector surrounded by a strip detector. The ITk strip detector consists of a four-layer barrel and a forward region composed of six discs on each side of the barrel. The current prototyping phase has resulted in the ITk Strip Detector Technical Design Report (TDR), which starts the pre-production readiness phase at the involved institutes. In this contribution we present the design of the ITk Strip Detector and current status of R&D of various detector components.

  12. Silicon strip detector qualification for the CMS experiment

    International Nuclear Information System (INIS)

    Kaussen, Gordon

    2008-01-01

    To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The performance of the participating two shells of the TIB, four rods of the TOB and two petals of the TEC (representing about 1% of the final strip tracker) could be studied in different magnetic fields over a period of approximately two month using cosmic muon signals. The last test before inserting the tracker in the CMS experiment was the Tracker Slice Test performed in spring/summer 2007 at the Tracker Integration Facility (TIF) at CERN after installing all subdetectors in the tracker support tube. Approximately 25% of the strip tracker +z side was powered and read out using a cosmic ray trigger built up of scintillation counters. In total, about 5 million muon events were recorded under various operating conditions. These events together with results from commissioning runs were used to study the detector response like cluster charges, signal-to-noise ratios and single strip noise behaviour as well as to identify faulty channels which turned out to be in the order of a few per mille. The performance of the silicon strip tracker during these different construction stages is discussed in this thesis with a special emphasis on the tracker end caps. (orig.)

  13. Silicon strip detector qualification for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kaussen, Gordon

    2008-10-06

    To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The performance of the participating two shells of the TIB, four rods of the TOB and two petals of the TEC (representing about 1% of the final strip tracker) could be studied in different magnetic fields over a period of approximately two month using cosmic muon signals. The last test before inserting the tracker in the CMS experiment was the Tracker Slice Test performed in spring/summer 2007 at the Tracker Integration Facility (TIF) at CERN after installing all subdetectors in the tracker support tube. Approximately 25% of the strip tracker +z side was powered and read out using a cosmic ray trigger built up of scintillation counters. In total, about 5 million muon events were recorded under various operating conditions. These events together with results from commissioning runs were used to study the detector response like cluster charges, signal-to-noise ratios and single strip noise behaviour as well as to identify faulty channels which turned out to be in the order of a few per mille. The performance of the silicon strip tracker during these different construction stages is discussed in this thesis with a special emphasis on the tracker end caps. (orig.)

  14. Radiation damage status of the ATLAS silicon strip detectors (SCT)

    CERN Document Server

    Kondo, Takahiko; The ATLAS collaboration

    2017-01-01

    The Silicon microstrip detector system (SCT) of the ATLAS experiment at LHC has been working well for about 7 years since 2010. The innermost layer has already received a few times of 10**13 1-MeV neutron-equivalent fluences/cm2. The evolutions of the radiation damage effects on strip sensors such as leakage current and full depletion voltages will be presented.

  15. Beam tests of ATLAS SCT silicon strip detector modules

    CERN Document Server

    Campabadal, F; Key, M; Lozano, M; Martínez, C; Pellegrini, G; Rafí, J M; Ullán, M; Johansen, L; Pommeresche, B; Stugu, B; Ciocio, A; Fadeev, V; Gilchriese, M G D; Haber, C; Siegrist, J; Spieler, H; Vu, C; Bell, P J; Charlton, D G; Dowell, John D; Gallop, B J; Homer, R J; Jovanovic, P; Mahout, G; McMahon, T J; Wilson, J A; Barr, A J; Carter, J R; Fromant, B P; Goodrick, M J; Hill, J C; Lester, C G; Palmer, M J; Parker, M A; Robinson, D; Sabetfakhri, A; Shaw, R J; Anghinolfi, F; Chesi, Enrico Guido; Chouridou, S; Fortin, R; Grosse-Knetter, J; Gruwé, M; Ferrari, P; Jarron, P; Kaplon, J; MacPherson, A; Niinikoski, T O; Pernegger, H; Roe, S; Rudge, A; Ruggiero, G; Wallny, R; Weilhammer, P; Bialas, W; Dabrowski, W; Grybos, P; Koperny, S; Blocki, J; Brückman, P; Gadomski, S; Godlewski, J; Górnicki, E; Malecki, P; Moszczynski, A; Stanecka, E; Stodulski, M; Szczygiel, R; Turala, M; Wolter, M; Ahmad, A; Benes, J; Carpentieri, C; Feld, L; Ketterer, C; Ludwig, J; Meinhardt, J; Runge, K; Mikulec, B; Mangin-Brinet, M; D'Onofrio, M; Donega, M; Moêd, S; Sfyrla, A; Ferrère, D; Clark, A G; Perrin, E; Weber, M; Bates, R L; Cheplakov, A P; Saxon, D H; O'Shea, V; Smith, K M; Iwata, Y; Ohsugi, T; Kohriki, T; Kondo, T; Terada, S; Ujiie, N; Ikegami, Y; Unno, Y; Takashima, R; Brodbeck, T; Chilingarov, A G; Hughes, G; Ratoff, P; Sloan, T; Allport, P P; Casse, G L; Greenall, A; Jackson, J N; Jones, T J; King, B T; Maxfield, S J; Smith, N A; Sutcliffe, P; Vossebeld, Joost Herman; Beck, G A; Carter, A A; Lloyd, S L; Martin, A J; Morris, J; Morin, J; Nagai, K; Pritchard, T W; Anderson, B E; Butterworth, J M; Fraser, T J; Jones, T W; Lane, J B; Postranecky, M; Warren, M R M; Cindro, V; Kramberger, G; Mandic, I; Mikuz, M; Duerdoth, I P; Freestone, J; Foster, J M; Ibbotson, M; Loebinger, F K; Pater, J; Snow, S W; Thompson, R J; Atkinson, T M; Bright, G; Kazi, S; Lindsay, S; Moorhead, G F; Taylor, G N; Bachindgagyan, G; Baranova, N; Karmanov, D; Merkine, M; Andricek, L; Bethke, Siegfried; Kudlaty, J; Lutz, Gerhard; Moser, H G; Nisius, R; Richter, R; Schieck, J; Cornelissen, T; Gorfine, G W; Hartjes, F G; Hessey, N P; de Jong, P; Muijs, A J M; Peeters, S J M; Tomeda, Y; Tanaka, R; Nakano, I; Dorholt, O; Danielsen, K M; Huse, T; Sandaker, H; Stapnes, S; Bargassa, Pedrame; Reichold, A; Huffman, T; Nickerson, R B; Weidberg, A; Doucas, G; Hawes, B; Lau, W; Howell, D; Kundu, N; Wastie, R; Böhm, J; Mikestikova, M; Stastny, J; Broklová, Z; Broz, J; Dolezal, Z; Kodys, P; Kubík, P; Reznicek, P; Vorobel, V; Wilhelm, I; Chren, D; Horazdovsky, T; Linhart, V; Pospísil, S; Sinor, M; Solar, M; Sopko, B; Stekl, I; Ardashev, E N; Golovnya, S N; Gorokhov, S A; Kholodenko, A G; Rudenko, R E; Ryadovikov, V N; Vorobev, A P; Adkin, P J; Apsimon, R J; Batchelor, L E; Bizzell, J P; Booker, P; Davis, V R; Easton, J M; Fowler, C; Gibson, M D; Haywood, S J; MacWaters, C; Matheson, J P; Matson, R M; McMahon, S J; Morris, F S; Morrissey, M; Murray, W J; Phillips, P W; Tyndel, M; Villani, E G; Dorfan, D E; Grillo, A A; Rosenbaum, F; Sadrozinski, H F W; Seiden, A; Spencer, E; Wilder, M; Booth, P; Buttar, C M; Dawson, I; Dervan, P; Grigson, C; Harper, R; Moraes, A; Peak, L S; Varvell, K E; Chu Ming Lee; Hou Li Shing; Lee Shih Chang; Teng Ping Kun; Wan Chang Chun; Hara, K; Kato, Y; Kuwano, T; Minagawa, M; Sengoku, H; Bingefors, N; Brenner, R; Ekelöf, T J C; Eklund, L; Bernabeu, J; Civera, J V; Costa, M J; Fuster, J; García, C; García, J E; González-Sevilla, S; Lacasta, C; Llosa, G; Martí i García, S; Modesto, P; Sánchez, J; Sospedra, L; Vos, M; Fasching, D; González, S; Jared, R C; Charles, E

    2005-01-01

    The design and technology of the silicon strip detector modules for the Semiconductor Tracker (SCT) of the ATLAS experiment have been finalised in the last several years. Integral to this process has been the measurement and verification of the tracking performance of the different module types in test beams at the CERN SPS and the KEK PS. Tests have been performed to explore the module performance under various operating conditions including detector bias voltage, magnetic field, incidence angle, and state of irradiation up to 3 multiplied by 1014 protons per square centimetre. A particular emphasis has been the understanding of the operational consequences of the binary readout scheme.

  16. Calibration and Monitoring of the CMS Silicon Strip Tracker detector

    CERN Document Server

    Giordano, D

    2008-01-01

    The CMS Silicon Strip Tracker (SST) is the largest detector of this kind ever built for a high energy physics experiment. It consists of more than ten millions of analog read-out channels, split between 15,148 detector modules. To ensure that the SST performance fully meets the physics requirements of the CMS experiment, the detector is precisely calibrated and constantly monitored to identify, at a very early stage, any possible problem both in the data acquisition and in the reconstruction chain. Due to its high granularity, the operation of the CMS SST is a challenging task. In this paper we describe the reconstruction strategies, the calibration procedures and the data quality monitoring system that the CMS Collaboration has devised to accurately operate the SST detector.

  17. Simulations of ATLAS silicon strip detector modules in ATHENA framework

    CERN Document Server

    Broklova, Zdenka; Dolezal, Zdenek

    2004-01-01

    This diploma thesis deals with properties of the silicon strip detector (SCT) modules of the ATLAS detector and building their software model. First part of the thesis consists of a brief overview of the ATLAS detector properties and focuses on the Inner Detector and its SCT part. Besides mechanical characteristics, analysis of capability to measure the charged particle momentum is placed there as well. Main features of the Athena framework and of the entire ATLAS offine software can be found in the further part. Athena framework is developed for simulations and future analyzing of the whole ATLAS measured data. This text is intended mainly for Athena newcomers. The main contribution of this thesis to ATLAS offine software preparation is implementation of the new SCT end-cap modules' geometry model, its detailed checking and preparation of the necessary software component for whole SCT subsystem for the Combined Testbeam (CTB - summer 2004). We perform checking the functionality of the whole simulation sequen...

  18. The ATLAS tracker strip detector for HL-LHC

    CERN Document Server

    Cormier, Kyle James Read; The ATLAS collaboration

    2016-01-01

    As part of the ATLAS upgrades for the High Luminsotiy LHC (HL-LHC) the current ATLAS Inner Detector (ID) will be replaced by a new Inner Tracker (ITk). The ITk will consist of two main components: semi-conductor pixels at the innermost radii, and silicon strips covering larger radii out as far as the ATLAS solenoid magnet including the volume currently occupied by the ATLAS Transition Radiation Tracker (TRT). The primary challenges faced by the ITk are the higher planned read out rate of ATLAS, the high density of charged particles in HL-LHC conditions for which tracks need to be resolved, and the corresponding high radiation doses that the detector and electronics will receive. The ITk strips community is currently working on designing and testing all aspects of the sensors, readout, mechanics, cooling and integration to meet these goals and a Technical Design Report is being prepared. This talk is an overview of the strip detector component of the ITk, highlighting the current status and the road ahead.

  19. Performance updating of CdZnTe strip-drift detectors

    DEFF Research Database (Denmark)

    Shorohov, M.; Tsirkunova, I.; Loupilov, A.

    2007-01-01

    59.6 and 662 keV correspondingly. Recently, significant progress was done in CdZnTe crystals growth technology. In the present paper we present preliminary result of performance updating of CdZnTe strip-drift detectors based on crystal of 10 x 10 x 6 mm 3 produced by Yinnel Tech company. Results...

  20. Splitting Strip Detector Clusters in Dense Environments

    CERN Document Server

    Nachman, Benjamin Philip; The ATLAS collaboration

    2018-01-01

    Tracking in high density environments, particularly in high energy jets, plays an important role in many physics analyses at the LHC. In such environments, there is significant degradation of track reconstruction performance. Between runs 1 and 2, ATLAS implemented an algorithm that splits pixel clusters originating from multiple charged particles, using charge information, resulting in the recovery of much of the lost efficiency. However, no attempt was made in prior work to split merged clusters in the Semi Conductor Tracker (SCT), which does not measure charge information. In spite of the lack of charge information in SCT, a cluster-splitting algorithm has been developed in this work. It is based primarily on the difference between the observed cluster width and the expected cluster width, which is derived from track incidence angle. The performance of this algorithm is found to be competitive with the existing pixel cluster splitting based on track information.

  1. The new silicon strip detectors for the CMS tracker upgrade

    International Nuclear Information System (INIS)

    Dragicevic, M.

    2010-01-01

    The first introductory part of the thesis describes the concept of the CMS experiment. The tasks of the various detector systems and their technical implementations in CMS are explained. To facilitate the understanding of the basic principles of silicon strip sensors, the subsequent chapter discusses the fundamentals in semiconductor technology, with particular emphasis on silicon. The necessary process steps to manufacture strip sensors in a so-called planar process are described in detail. Furthermore, the effects of irradiation on silicon strip sensors are discussed. To conclude the introductory part of the thesis, the design of the silicon strip sensors of the CMS Tracker are described in detail. The choice of the substrate material and the complex geometry of the sensors are reviewed and the quality assurance procedures for the production of the sensors are presented. Furthermore the design of the detector modules are described. The main part of this thesis starts with a discussion on the demands on the tracker caused by the increase in luminosity which is proposed as an upgrade to the LHC accelerator (sLHC). This chapter motivates the work I have conducted and clarifies why the solutions proposed by myself are important contributions to the upgrade of the CMS tracker. The following chapters present the concepts that are necessary to operate the silicon strip sensors at sLHC luminosities and additional improvements to the construction and quality assurance of the sensors and the detector modules. The most important concepts and works presented in chapters 7 to 9 are: Development of a software framework to enable the flexible and quick design of test structures and sensors. Selecting a suitable sensor material which is sufficiently radiation hard. Design, implementation and production of a standard set of test structures to enable the quality assurance of such sensors and any future developments. Electrical characterisation of the test structures and analysis

  2. A Proposal to Upgrade the Silicon Strip Detector

    Energy Technology Data Exchange (ETDEWEB)

    Matis, Howard; Michael, LeVine; Jonathan, Bouchet; Stephane, Bouvier; Artemios, Geromitsos; Gerard, Guilloux; Sonia, Kabana; Christophe, Renard; Howard, Matis; Jim, Thomas; Vi Nham, Tram

    2007-11-05

    The STAR Silicon Strip Detector (SSD) was built by a collaboration of Nantes, Strasbourg and Warsaw collaborators. It is a beautiful detector; it can provide 500 mu m scale pointing resolution at the vertex when working in combination with the TPC. It was first used in Run 4, when half the SSD was installed in an engineering run. The full detector was installed for Run 5 (the Cu-Cu run) and the operation and performance of the detector was very successful. However, in preparation for Run 6, two noisy ladders (out of 20) were replaced and this required that the SSD be removed from the STAR detector. The re-installation of the SSD was not fully successful and so for the next two Runs, 6 and 7, the SSD suffered a cooling system failure that allowed a large fraction of the ladders to overheat and become noisy, or fail. (The cause of the SSD cooling failure was rather trivial but the SSD could not be removed betweens Runs 6 and 7 due to the inability of the STAR detector to roll along its tracks at that time.)

  3. A Proposal to Upgrade the Silicon Strip Detector

    International Nuclear Information System (INIS)

    Matis, Howard; Michael, LeVine; Jonathan, Bouchet; Stephane, Bouvier; Artemios, Geromitsos; Gerard, Guilloux; Sonia, Kabana; Christophe, Renard; Howard, Matis; Jim, Thomas; Vi Nham, Tram

    2007-01-01

    The STAR Silicon Strip Detector (SSD) was built by a collaboration of Nantes, Strasbourg and Warsaw collaborators. It is a beautiful detector; it can provide 500 mu m scale pointing resolution at the vertex when working in combination with the TPC. It was first used in Run 4, when half the SSD was installed in an engineering run. The full detector was installed for Run 5 (the Cu-Cu run) and the operation and performance of the detector was very successful. However, in preparation for Run 6, two noisy ladders (out of 20) were replaced and this required that the SSD be removed from the STAR detector. The re-installation of the SSD was not fully successful and so for the next two Runs, 6 and 7, the SSD suffered a cooling system failure that allowed a large fraction of the ladders to overheat and become noisy, or fail. (The cause of the SSD cooling failure was rather trivial but the SSD could not be removed between Runs 6 and 7 due to the inability of the STAR detector to roll along its tracks at that time.)

  4. EMC Diagnosis and Corrective Actions for Silicon Strip Tracker Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Arteche, F.; /CERN /Imperial Coll., London; Rivetta, C.; /SLAC

    2006-06-06

    The tracker sub-system is one of the five sub-detectors of the Compact Muon Solenoid (CMS) experiment under construction at CERN for the Large Hadron Collider (LHC) accelerator. The tracker subdetector is designed to reconstruct tracks of charged sub-atomic particles generated after collisions. The tracker system processes analogue signals from 10 million channels distributed across 14000 silicon micro-strip detectors. It is designed to process signals of a few nA and digitize them at 40 MHz. The overall sub-detector is embedded in a high particle radiation environment and a magnetic field of 4 Tesla. The evaluation of the electromagnetic immunity of the system is very important to optimize the performance of the tracker sub-detector and the whole CMS experiment. This paper presents the EMC diagnosis of the CMS silicon tracker sub-detector. Immunity tests were performed using the final prototype of the Silicon Tracker End-Caps (TEC) system to estimate the sensitivity of the system to conducted noise, evaluate the weakest areas of the system and take corrective actions before the integration of the overall detector. This paper shows the results of one of those tests, that is the measurement and analysis of the immunity to CM external conducted noise perturbations.

  5. Study of inter-strip gap effects and efficiency for full energy detection of double sided silicon strip detectors

    International Nuclear Information System (INIS)

    Fisichella, M.; Forneris, J.; Grassi, L.

    2015-01-01

    We performed a characterization of Double Sided Silicon Strip Detectors (DSSSD) with the aim to carry out a systematic study of the inter-strip effects on the energy measurement of charged particles. The dependence of the DSSSD response on ion, energy and applied bias has been investigated. (author)

  6. A silicon strip module for the ATLAS inner detector upgrade in the super LHC collider

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Sevilla, S., E-mail: Sergio.Gonzalez.Sevilla@cern.ch [DPNC, University of Geneva, CH 1211 Geneva 4 (Switzerland); Barbier, G. [DPNC, University of Geneva, CH 1211 Geneva 4 (Switzerland); Anghinolfi, F. [European Organization for Nuclear Research, CERN CH-1211, Geneva 23 (Switzerland); Cadoux, F.; Clark, A. [DPNC, University of Geneva, CH 1211 Geneva 4 (Switzerland); Dabrowski, W.; Dwuznik, M. [AGH University of Sceince and Technology, Faculty of Physics and Applied Computer Science, Krakow (Poland); Ferrere, D. [DPNC, University of Geneva, CH 1211 Geneva 4 (Switzerland); Garcia, C. [IFIC, Instituto de Fisica Corpuscular (CSIC-Universitat de Valencia), Edificio Investigacion Paterna, Apartado 22085 46071 Valencia (Spain); Ikegami, Y. [KEK, High Energy Accelerator Research Organization, Oho 1-1, Tsukuba, Ibaraki 305-0801 (Japan); Hara, K. [University of Tsukuba, School of Pure and Applied Sciences, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8571 (Japan); Jakobs, K. [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Kaplon, J. [European Organization for Nuclear Research, CERN CH-1211, Geneva 23 (Switzerland); Koriki, T. [KEK, High Energy Accelerator Research Organization, Oho 1-1, Tsukuba, Ibaraki 305-0801 (Japan); Lacasta, C. [IFIC, Instituto de Fisica Corpuscular (CSIC-Universitat de Valencia), Edificio Investigacion Paterna, Apartado 22085 46071 Valencia (Spain); La Marra, D. [DPNC, University of Geneva, CH 1211 Geneva 4 (Switzerland); Marti i Garcia, S. [IFIC, Instituto de Fisica Corpuscular (CSIC-Universitat de Valencia), Edificio Investigacion Paterna, Apartado 22085 46071 Valencia (Spain); Parzefall, U. [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Pohl, M. [DPNC, University of Geneva, CH 1211 Geneva 4 (Switzerland); Terada, S. [KEK, High Energy Accelerator Research Organization, Oho 1-1, Tsukuba, Ibaraki 305-0801 (Japan)

    2011-04-21

    The ATLAS detector is a general purpose experiment designed to fully exploit the discovery potential of the Large Hadron Collider (LHC) at a nominal luminosity of 10{sup 34} cm{sup -2} s{sup -1}. It is expected that after several years of successful data-taking, the LHC physics program will be extended by increasing the peak luminosity by one order of magnitude. For ATLAS, an upgrade scenario will imply the complete replacement of the Inner Detector (ID), since the current tracker will not provide the required performance due to cumulated radiation damage and a dramatic increase in the detector occupancy. In this paper, a proposal of a double-sided silicon micro-strip module for the short-strip region of the future ATLAS ID is presented. The expected thermal performance based upon detailed FEA simulations is discussed. First electrical results from a prototype version of the next generation readout front-end chips are also shown.

  7. Data quality monitoring of the CMS Silicon Strip Tracker detector

    International Nuclear Information System (INIS)

    Benucci, L.

    2010-01-01

    The Physics and Data Quality Monitoring (DQM) framework aims at providing a homogeneous monitoring environment across various applications related to data taking at the CMS experiment. In this contribution, the DQM system for the Silicon Strip Tracker will be introduced. The set of elements to assess the status of detector will be mentioned, along with the way to identify problems and trace them to specific tracker elements. Monitoring tools, user interfaces and automated software will be briefly described. The system was used during extensive cosmic data taking of CMS in Autumn 2008, where it demonstrated to have a flexible and robust implementation and has been essential to improve the understanding of the detector. CMS Collaboration believes that this tool is now mature to face the forthcoming data-taking era.

  8. Silicon strip detector qualification for the CMS experiment

    CERN Document Server

    Kaußen, Gordon

    2008-01-01

    The Compact Muon Solenoid (CMS) is one of the four experiments being installed at the Large Hadron Collider (LHC) which is located at the european organization for nuclear research CERN in Geneva. This proton-proton collider will explore a new energy regime of up to 14TeV center-of-mass energy. To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The entire strip tracker spans an active area of about 198m2 and consists of approximately 16000 modules. Before the silicon sensors were assembl...

  9. Strip detector for the ATLAS detector upgrade for the high-luminosity LHC

    CERN Document Server

    Madaffari, Daniele; The ATLAS collaboration

    2017-01-01

    The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential of the LHC through a sizeable increase in the luminosity, reaching 1x10$^{35}$ cm$^{-2}$s$^{-1}$ after 10 years of operation. A consequence of this increased luminosity is the expected radiation damage at an integrated luminosity of 3000 fb$^{-1}$, requiring the tracking detectors to withstand hadron fluencies to over 1x10$^{16}$ 1 MeV neutron equivalent per cm$^2$. With the addition of increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk), which will consist of both strip and pixelated silicon detectors. The physics motivations, required performance characteristics and basic design of the proposed upgrade of the strip detector will be a subject of this talk. Present ideas and solutions for the strip detector and current research and development program will be discussed.

  10. Silicon strip detector for a novel 2D dosimetric method for radiotherapy treatment verification

    Science.gov (United States)

    Bocci, A.; Cortés-Giraldo, M. A.; Gallardo, M. I.; Espino, J. M.; Arráns, R.; Alvarez, M. A. G.; Abou-Haïdar, Z.; Quesada, J. M.; Pérez Vega-Leal, A.; Pérez Nieto, F. J.

    2012-05-01

    The aim of this work is to characterize a silicon strip detector and its associated data acquisition system, based on discrete electronics, to obtain in a near future absorbed dose maps in axial planes for complex radiotherapy treatments, using a novel technique. The experimental setup is based on two phantom prototypes: the first one is a polyethylene slab phantom used to characterize the detector in terms of linearity, percent depth dose, reproducibility, uniformity and penumbra. The second one is a cylindrical phantom, specifically designed and built to recreate conditions close to those normally found in clinical environments, for treatment planning assessment. This system has been used to study the dosimetric response of the detector, in the axial plane of the phantom, as a function of its angle with respect to the irradiation beam. A software has been developed to operate the rotation of this phantom and to acquire signals from the silicon strip detector. As an innovation, the detector was positioned inside the cylindrical phantom parallel to the beam axis. Irradiation experiments were carried out with a Siemens PRIMUS linac operating in the 6 MV photon mode at the Virgen Macarena Hospital. Monte Carlo simulations were performed using Geant4 toolkit and results were compared to Treatment Planning System (TPS) calculations for the absorbed dose-to-water case. Geant4 simulations were used to estimate the sensitivity of the detector in different experimental configurations, in relation to the absorbed dose in each strip. A final calibration of the detector in this clinical setup was obtained by comparing experimental data with TPS calculations.

  11. The Control System for the CMS Strip Tracking Detector

    CERN Document Server

    Fahrer, Manuel; Chen, Jie; Dierlamm, Alexander; Frey, Martin; Masetti, Lorenzo; Militaru, Otilia; Shah, Yousaf; Stringer, Robert; Tsirou, Andromachi

    2008-01-01

    The Tracker of the CMS silicon strip tracking detector covers a surface of 206 m2. 9648128 channels are available on 75376 APV front-end chips on 15232 modules, built of 24328 silicon sensors. The power supply of the detector modules is split up in 1944 power supplies with two low voltage for front end power and two high voltage channels each for the bias voltage of the silicon sensors. In addition 356 low voltage channels are needed to power the control chain. The tracker will run at -20°C at low relative humidity for at least 10 years. The Tracker Control System handles all interdependencies of control, low and high voltages, as well as fast ramp downs in case of higher than allowed temperatures or currents in the detector and experimental cavern problems. This is ensured by evaluating $10^{4}$ power supply parameters, $10^{3}$ information from Tracker Safety System and $10^{5}$ information from the tracker front end.

  12. Interference coupling mechanisms in Silicon Strip Detectors - CMS tracker "wings" A learned lesson for SLHC

    CERN Document Server

    Arteche, F; Rivetta, C

    2009-01-01

    The identification of coupling mechanisms between noise sources and sensitive areas of the front-end electronics (FEE) in the previous CMS tracker sub-system is critical to optimize the design and integration of integrated circuits, sensors and power distribution circuitry for the proposed SLHC Silicon Strip Tracker systems. This paper presents a validated model of the noise sensitivity observed in the Silicon Strip Detector-FEE of the CMS tracker that allows quantifying both the impact of the noise coupling mechanisms and the system immunity against electromagnetic interferences. This model has been validated based on simulations using finite element models and immunity tests conducted on prototypes of the Silicon Tracker End-Caps (TEC) and Outer Barrel (TOB) systems. The results of these studies show important recommendations and criteria to be applied in the design of future detectors to increase the immunity against electromagnetic noise.

  13. Pulse processing CMOS ASIC for Si-strip/PIN detectors

    International Nuclear Information System (INIS)

    Chandratre, V.B.; Sardesai, S.V.; Kataria, S.K.

    2004-01-01

    The paper presents the design of an 8-channel front-end signal processing ASIC for Si-strip detectors with capacitance from 1 to 40 pf. Each channel consists of a charge amplifier, a shaper amplifier (CR-RC 3 ) and a track-hold stage. The channel outputs are connected to an analog multiplexer which is controlled by an external clock for serial readout. The peaking time is adjustable over 500 ns-1.2us in steps by external control. There is provision for changing gain and polarity. The circuit has a power dissipation of 16 mw per channel and is designed to fabricate in 1.2 um CMOS technology. The 0pf noise is ∼400e. The chip has an area of 5 by 5 mm with target package 48 pin CLCC. (author)

  14. The ATLAS ITk Strip Detector. Status of R&D

    CERN Document Server

    AUTHOR|(SzGeCERN)727037; The ATLAS collaboration

    2016-01-01

    While the LHC at CERN is ramping up luminosity after the discovery of the Higgs Boson in the ATLAS and CMS experiments in 2012, upgrades to the LHC and experiments are planned. The major upgrade is foreseen for 2024, with a roughly tenfold increase in luminosity, resulting in corresponding increases in particle rates and radiation doses. In ATLAS the entire Inner Detector will be replaced for Phase-2 running with an all-silicon system. This paper concentrates on the strip part. Its layout foresees low-mass and modular yet highly integrated double-sided structures for the barrel and forward region. The design features conceptually simple modules made from electronic hybrids glued directly onto the silicon. Modules will then be assembled on both sides of large carbon-core structures with integrated cooling and electrical services.

  15. High energy X-ray photon counting imaging using linear accelerator and silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Y., E-mail: cycjty@sophie.q.t.u-tokyo.ac.jp [Department of Bioengineering, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Shimazoe, K.; Yan, X. [Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Ueda, O.; Ishikura, T. [Fuji Electric Co., Ltd., Fuji, Hino, Tokyo 191-8502 (Japan); Fujiwara, T. [National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Uesaka, M.; Ohno, M. [Nuclear Professional School, the University of Tokyo, 2-22 Shirakata-shirane, Tokai, Ibaraki 319-1188 (Japan); Tomita, H. [Department of Quantum Engineering, Nagoya University, Furo, Chikusa, Nagoya 464-8603 (Japan); Yoshihara, Y. [Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Takahashi, H. [Department of Bioengineering, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2016-09-11

    A photon counting imaging detector system for high energy X-rays is developed for on-site non-destructive testing of thick objects. One-dimensional silicon strip (1 mm pitch) detectors are stacked to form a two-dimensional edge-on module. Each detector is connected to a 48-channel application specific integrated circuit (ASIC). The threshold-triggered events are recorded by a field programmable gate array based counter in each channel. The detector prototype is tested using 950 kV linear accelerator X-rays. The fast CR shaper (300 ns pulse width) of the ASIC makes it possible to deal with the high instant count rate during the 2 μs beam pulse. The preliminary imaging results of several metal and concrete samples are demonstrated.

  16. Radiation Damage Effects and Performance of Silicon Strip Detectors using LHC Readout Electronics

    CERN Document Server

    AUTHOR|(CDS)2067734

    1998-01-01

    Future high energy physics experiments as the ATLAS experiment at CERN, will use silicon strip detectors for fast and high precision tracking information. The high hadron fluences in these experiments cause permanent damage in the silicon.Additional energy levels are introduced in the bandgap thus changing the electrical properties such as leakage current and full depletion voltage V_fd .Very high leakage currents are observed after irradiation and lead to higher electronic noise and thus decrease the spatial resolution.V_fd increases to a few hundred volts after irradiation and eventually beyond the point of stable operating voltages. Prototype detectors with either p-implanted strips (p-in-n) and n-implanted strip detectors (n-in-n) were irradiated to the maximum expected fluence in ATLAS.The irradiation and the following study of the current and V_fd were carried out under ATLAS operational conditions.The evolution of V_fd after irradiation is compared to models based on diode irradiations.The qualitative ...

  17. Technical Design Report for the ATLAS Inner Tracker Strip Detector

    CERN Document Server

    Collaboration, ATLAS

    2017-01-01

    This is the first of two Technical Design Report documents that describe the upgrade of the central tracking system for the ATLAS experiment for the operation at the High Luminosity LHC (HL-LHC) starting in the middle of 2026. At this time the LHC will have been upgraded to reach a peak instantaneous luminosity of 7.5x10^34 cm^[-2]s^[-1], which corresponds to approximately 200 inelastic proton-proton collisions per beam crossing. The new Inner Tracker (ITk) will be operational for more than ten years, during which ATLAS aims to accumulate a total data set of 3,000 fb^[-1]. Meeting these requirements presents a unique challenge for the design of an all-silicon tracking system that consists of a pixel detector at small radius close to the beam line and a large-area strip tracking detector surrounding it. This document presents in detail the requirements of the new tracker, its layout and expected performance including the results of several benchmark physics studies at the highest numbers of collisions per beam...

  18. Study of 236U/238U ratio at CIRCE using a 16-strip silicon detector with a TOF system

    Directory of Open Access Journals (Sweden)

    De Cesare M.

    2015-01-01

    Full Text Available Accelerator Mass Spectrometry (AMS is presently the most sensitive technique for the measurement of long-lived actinides, e.g. 236U and xPu isotopes. A new actinide AMS system, based on a 3-MV pelletron tandem accelerator, is operated at the Center for Isotopic Research on Cultural and Environmental Heritage (CIRCE in Caserta, Italy. In this paper we report on the procedure adopted to increase the 236U abundance sensitivity as low as possible. The energy and position determinations of the 236U ions, using a 16-strip silicon detector have been obtained. A 236U/238U isotopic ratio background level of about 2.9×10−11 was obtained, summing over all the strips, using a Time of Flight-Energy (TOF-E system with a 16-strip silicon detector (4.9×10−12 just with one strip.

  19. Study of 236U/238U ratio at CIRCE using a 16-strip silicon detector with a TOF system

    Science.gov (United States)

    De Cesare, M.; De Cesare, N.; D'Onofrio, A.; Gialanella, L.; Terrasi, F.

    2015-04-01

    Accelerator Mass Spectrometry (AMS) is presently the most sensitive technique for the measurement of long-lived actinides, e.g. 236U and xPu isotopes. A new actinide AMS system, based on a 3-MV pelletron tandem accelerator, is operated at the Center for Isotopic Research on Cultural and Environmental Heritage (CIRCE) in Caserta, Italy. In this paper we report on the procedure adopted to increase the 236U abundance sensitivity as low as possible. The energy and position determinations of the 236U ions, using a 16-strip silicon detector have been obtained. A 236U/238U isotopic ratio background level of about 2.9×10-11 was obtained, summing over all the strips, using a Time of Flight-Energy (TOF-E) system with a 16-strip silicon detector (4.9×10-12 just with one strip).

  20. MUST, a set of strip detectors for studying radioactive beams induced reactions

    International Nuclear Information System (INIS)

    Blumenfeld, Y.; Barbier, A.; Beaumel, D.; Charlet, D.; Clavelin, J.F.; Douet, R.; Engrand, M.; Lebon, S.; Lelong, P.; Lesage, A.; Leven, V.; Lhenry, I.; Marechal, F.; Petizon, L.; Pouthas, J.; Richard, A.; Rougier, D.; Soulet, C.; Suomijaervi, T.; Volkov, P.; Voltolini, G.

    1996-01-01

    This report states the specificity of light particles elastic scattering, and the need of detecting recoil protons to improve angular resolution. Then the development of a specific MUST strip detector is detailed: 60 strips detectors with Si O sub 2 dielectric, that yield 500 ps time resolution, and Si (Li) detectors following next. A versatile data acquisition system has been developed too, with CAMAC interface to suit to any experimental plant. (D.L.)

  1. Status of the silicon strip vertex detector for the Mark II experiment at the SLC

    International Nuclear Information System (INIS)

    Adolphsen, C.; Gratta, G.; Litke, A.

    1987-10-01

    We are constructing a silicon strip vertex detector to be used in the Mark II detector in the study of Z 0 decays at the SLAC Linear Collider. The status of the project, including the performance of the individual silicon detector modules, is presented. 6 refs., 8 figs., 2 tabs

  2. Double peak electric field distortion in heavily irradiated silicon strip detectors

    CERN Document Server

    Eremin, Vladimir; Roe, Shaun; Ruggiero, G; Verbitskaya, E

    2004-01-01

    Non-uniform distribution of the electric field outlined as double peak distortion (DPD) is considered for heavily irradiated silicon strip detectors, which were developed for the CERN-ATLAS semiconductor tracker. DPD originates from the non-uniform accumulation of electrons and holes from the bulk generated current that are captured by radiation induced defects: deep acceptors and donors with mid-gap energy levels. This corresponds to the formation of the low electric field region in the detector central part that consequently will delay charge collection. The electric field distributions at different reverse biases, fluences and detector operational temperatures are calculated using a one-dimensional Poisson equation as it was done earlier for pad detectors. It has been shown that due to the electric field focusing at the strips the DPD effect is more pronounced for strip detectors as compared to that in pad detectors. The double peak electric field distribution is evinced experimentally in current pulse res...

  3. First results of the front-end ASIC for the strip detector of the PANDA MVD

    Science.gov (United States)

    Quagli, T.; Brinkmann, K.-T.; Calvo, D.; Di Pietro, V.; Lai, A.; Riccardi, A.; Ritman, J.; Rivetti, A.; Rolo, M. D.; Stockmanns, T.; Wheadon, R.; Zambanini, A.

    2017-03-01

    PANDA is a key experiment of the future FAIR facility and the Micro Vertex Detector (MVD) is the innermost part of its tracking system. PASTA (PAnda STrip ASIC) is the readout chip for the strip part of the MVD. The chip is designed to provide high resolution timestamp and charge information with the Time over Threshold (ToT) technique. Its architecture is based on Time to Digital Converters with analog interpolators, with a time bin width of 50 ps. The chip implements Single Event Upset (SEU) protection techniques for its digital parts. A first full-size prototype with 64 channels was produced in a commercial 110 nm CMOS technology and the first characterizations of the prototype were performed.

  4. Assembly of an endcap of the ATLAS silicon strip detector at NIKHEF, Amsterdam.

    CERN Multimedia

    Ginter, P

    2005-01-01

    Assembly of an endcap of the ATLAS silicon strip detector (SCT) at NIKHEF, Amsterdam. Technicians are mounting the power distribution cables on the cylinder that houses nine disks with silicon sensors.

  5. Response of CZT drift-strip detector to X- and gamma rays

    DEFF Research Database (Denmark)

    Kuvvetli, Irfan; Budtz-Jørgensen, Carl; Gerward, Leif

    2001-01-01

    The drift-strip method for improving the energy response of a CdZnTe (CZT) detector to hard X- and gamma rays is discussed. Results for a 10 x 10 x 3 mm(3) detector crystal demonstrate a remarkable improvement of the energy resolution. The full width at half maximum (FWHM) is 2.18 keV (3.6%), 2...

  6. Silicon two-coordinate detector with separable pad-strip readout

    International Nuclear Information System (INIS)

    Barabash, L.S.; Babukh, A.V.; Frolov, V.N.; Kazarinov, M.Yu.; Popov, A.A.; Sandukovskij, V.G.; Chalyshev, V.V.

    1996-01-01

    The characteristics of resistive layer Si microstrip detector with two versions of the readout system are presented. One version used the usual single coordinate strip system of 1 mm pitch. The second version used a two coordinate pad-strip system of 3.6 mm pitch ('chess board'). The registration precision of the detector was studied with a UV laser. The two-dimensional imaging ability of the detector with α-particles and with an 241 Am γ-source is shown. 5 refs., 9 figs

  7. The readout chain for the P-bar ANDA MVD strip detector

    International Nuclear Information System (INIS)

    Schnell, R.; Brinkmann, K.-Th.; Pietro, V. Di; Riccardi, A.; Zaunick, H.-G.; Kleines, H.; Goerres, A.; Rivetti, A.; Rolo, M.D.; Sohlbach, H.

    2015-01-01

    The P-bar ANDA (antiProton ANnihilation at DArmstadt) experiment will study the strong interaction in annihilation reactions between an antiproton beam and a stationary gas jet target. The detector will comprise different sub-detectors for tracking, particle identification and calorimetry. The Micro-Vertex Detector (MVD) as the innermost part of the tracking system will allow precise tracking and detection of secondary vertices. For the readout of the double-sided silicon strip sensors a custom-made ASIC is being developed, employing the Time-over-Threshold (ToT) technique for digitization and utilize time-to-digital converters (TDC) to provide a high-precision time stamp of the hit. A custom-made Module Data Concentrator ASIC (MDC) will multiplex the data of all front-ends of one sensor towards the CERN-developed GBT chip set (GigaBit Transceiver). The MicroTCA-based MVD Multiplexer Board (MMB) at the off-detector site will receive and concentrate the data from the GBT links and transfer it to FPGA-based compute nodes for global event building

  8. Transparent silicon strip sensors for the optical alignment of particle detector systems

    International Nuclear Information System (INIS)

    Blum, W.; Kroha, H.; Widmann, P.

    1995-05-01

    Modern large-area precision tracking detectors require increasing accuracy for the alignment of their components. A novel multi-point laser alignment system has been developed for such applications. The position of detector components with respect to reference laser beams is monitored by semi-transparent optical position sensors which work on the principle of silicon strip photodiodes. Two types of custom designed transparent strip sensors, based on crystalline and on amorphous silicon as active material, have been studied. The sensors are optimised for the typical diameters of collimated laser beams of 3-5 mm over distances of 10-20 m. They provide very high position resolution, on the order of 1 μm, uniformly over a wide measurement range of several centimeters. The preparation of the sensor surfaces requires special attention in order to achieve high light transmittance and minimum distortion of the traversing laser beams. At selected wavelengths, produced by laser diodes, transmission rates above 90% have been achieved. This allows to position more than 30 sensors along one laser beam. The sensors will be equipped with custom designed integrated readout electronics. (orig.)

  9. Gas detector with a μm size strips anode

    International Nuclear Information System (INIS)

    Oed, A.

    1988-01-01

    A flat electrode device for an ionizing radiation multidetector, particularly for an X-ray detector used in tomodensitometry, is presented. It consists of either two active electrodes of the same kind, or an anode-electrode and a cathode electrode, on opposite sides of a base plate. The device avoids problems linked to flatness and parallelism, and the base plate consists of at least two intermediate plates separated by a space containing at least layer of binding material. The device thus overcomes difficulties associated with thickness and the need to stop ionizing radiation from passing from one cell to another by traversing the base plate. The steps of the fabrication process are detailed [fr

  10. Investigation of the charge collection for strongly irradiated silicon strip detectors of the CMS ECAL Preshower

    International Nuclear Information System (INIS)

    Bloch, Ph.; Peisert, A.; Chang, Y.H.; Chen, A.E.; Hou, S.; Lin, W.T.; Cheremukhin, A.E.; Golutvin, I.A.; Urkinbaev, A.R.; Zamyatin, N.I.; Loukas, D.

    2001-01-01

    Strongly irradiated (2.3·10 14 n/cm 2 ) silicon strip detectors of different size, thickness and different design options were tested in a muon beam at CERN in 1999. A charge collection efficiency in excess of 85% and a signal-to-noise ratio of about 6 are obtained in all cases at high enough bias voltage. Details of the charge collection in the interstrip and the guard ring region and cross-talk between strips were also studied. We find that the charge collection efficiency and the cross-talk between strips depend on the interstrip distance

  11. Beam tests of ATLAS SCT silicon strip detector modules

    Czech Academy of Sciences Publication Activity Database

    Campabadal, F.; Fleta, C.; Key, M.; Böhm, Jan; Mikeštíková, Marcela; Šťastný, Jan

    2005-01-01

    Roč. 538, - (2005), s. 384-407 ISSN 0168-9002 R&D Projects: GA MŠk(CZ) 1P04LA212 Institutional research plan: CEZ:AV0Z10100502 Keywords : ATLAS * silicon * micro-strip * beam * test Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.224, year: 2005

  12. Commissioning, operation and performance of the CMS Silicon Strip Tracker detector

    CERN Document Server

    Demina, Regina

    2009-01-01

    The CMS silicon strip tracker is the largest device of this type ever built for detection of charge particles produced in beam-beam collisions. There are 24244 single-sided micro-strip sensors covering an active area of over 200 square meters, and nearly 10 millions channels to be read out. The detector was installed inside CMS in December 2007, and it was commissioned during the summer 2008. Since then it integrated several global CMS cosmic muons data taking and performances were measured. The commissioning strategy, operational experience learned during the data taking period, and detector performance results will be presented.

  13. CZT drift strip detectors for high energy astrophysics

    DEFF Research Database (Denmark)

    Kuvvetli, Irfan; Budtz-Jørgensen, Carl; Caroli, E.

    2010-01-01

    Requirements for X- and gamma ray detectors for future High Energy Astrophysics missions include high detection efficiency and good energy resolution as well as fine position sensitivity even in three dimensions.We report on experimental investigations on the CZT drift detector developed DTU Spac...

  14. Radiation damage measurements on CZT drift strip detectors

    DEFF Research Database (Denmark)

    Kuvvetli, Irfan; Budtz-Jørgensen, Carl; Korsbech, Uffe C C

    2003-01-01

    from 2 x 10(8) to 60 x 10(8) p(+)/cm(2). Even for the highest fluences, which had a dramatic effect on the spectroscopic performance, we were able to recover the detectors after an appropriate annealing procedure. The radiation damage was studied as a function of depth inside the detector material...

  15. GaAs strip detectors: the Australian production program

    International Nuclear Information System (INIS)

    Butcher, K.S.A.; Alexiev, D.

    1995-01-01

    The Australian High Energy Physics consortium (composed of the University of Melbourne, the University of Sydney and ANSTO) has been investigating the possibility of producing a large area wheel of SI GaAs detectors for the ATLAS detector array. To help assess the extent of Australia's role in this venture a few SI GaAs microstrip detectors are to be manufactured under contract by the CSIRO division of Radiophysics GaAs IC Prototyping Facility. The planned production of the devices is discussed. First, the reasons for producing the detectors here in Australia are examined, then some basic characteristics of the material are considered, and finally details are provided of the design used for the manufacture of the devices. Two sets of detectors will be produced using the standard Glasgow production recipe; SIGaAs and GaN. The Glasgow mask set is being used as a benchmark against which to compare the Australian devices

  16. Bismuth-based electrochemical stripping analysis

    Science.gov (United States)

    Wang, Joseph

    2004-01-27

    Method and apparatus for trace metal detection and analysis using bismuth-coated electrodes and electrochemical stripping analysis. Both anodic stripping voltammetry and adsorptive stripping analysis may be employed.

  17. High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix

    CERN Document Server

    Braem, André; Joram, C; Séguinot, Jacques; Weilhammer, P; De Leo, R; Nappi, E; Lustermann, W; Schinzel, D; Johnson, I; Renker, D; Albrecht, S

    2007-01-01

    We describe a novel method to extract the axial coordinate from a matrix of long axially oriented crystals, which is based on wavelength shifting plastic strips. The method allows building compact 3-D axial gamma detector modules for PET scanners with excellent 3-dimensional spatial, timing and energy resolution while keeping the number of readout channels reasonably low. A voxel resolution of about 10 mm3 is expected. We assess the performance of the method in two independent ways, using classical PMTs and G-APDs to read out the LYSO (LSO) scintillation crystals and the wavelength shifting strips. We observe yields in excess of 35 photoelectrons from the strips for a 511 keV gamma and reconstruct the axial coordinate with a precision of about 2.5 mm (FWHM).

  18. A new semicustom integrated bipolar amplifier for silicon strip detectors

    International Nuclear Information System (INIS)

    Zimmerman, T.

    1989-01-01

    The QPA02 is a four channel DC coupled two stage transimpedance amplifier designed at Fermilab on a semicustom linear array (Quickchip 2S) manufactured by Tektronix. The chip was developed as a silicon strip amplifier but may have other applications as well. Each channel consists of a preamplifier and a second stage amplifier/sharper with differential output which can directly drive a transmission line (90 to 140 ohms). External bypass capacitors are the only discrete components required. QPA02 has been tested and demonstrated to be an effective silicon strip amplifier. Other applications may exist which can use this amplifier or a modified version of this amplifier. For example, another design is now in progress for a wire chamber amplifier, QPA03, to be reported later. Only a relatively small effort was required to modify the design and layout for this application. 11 figs

  19. Development of a silicon micro-strip detector for tracking high intensity secondary beams

    Science.gov (United States)

    Kiuchi, R.; Asano, H.; Hasegawa, S.; Honda, R.; Ichikawa, Y.; Imai, K.; Joo, C. W.; Nakazawa, K.; Sako, H.; Sato, S.; Shirotori, K.; Sugimura, H.; Tanida, K.; Watabe, T.

    2014-11-01

    A single-sided silicon micro-strip detector (SSD) has been developed as a tracking detector for hadron experiments at J-PARC where secondary meson beams with intensities of up to 108 Hz are available. The performance of the detector has been investigated and verified in a series of test beam experiments in the years 2009-2011. The hole mobility was deduced from the analysis of cluster events. The beam rate dependence was measured in terms of timing resolution, signal-to-noise ratio, and hit efficiency. This paper describes the detector with its read-out system, details of the test experiments, and discusses the performance achieved.

  20. Development of a silicon micro-strip detector for tracking high intensity secondary beams

    Energy Technology Data Exchange (ETDEWEB)

    Kiuchi, R. [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, Naka, Ibaraki 319-1195 (Japan); Asano, H. [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Hasegawa, S. [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, Naka, Ibaraki 319-1195 (Japan); Honda, R. [Department of Physics, Tohoku University, Sendai 980-8578 (Japan); Ichikawa, Y. [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, Naka, Ibaraki 319-1195 (Japan); Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Imai, K. [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, Naka, Ibaraki 319-1195 (Japan); Joo, C.W. [Department of Physics and Astronomy, Seoul National University, Seoul 151-747 (Korea, Republic of); Nakazawa, K. [Physics Department, Gifu University, Gifu 501-1193 (Japan); Sako, H.; Sato, S. [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, Naka, Ibaraki 319-1195 (Japan); Shirotori, K. [Research Center for Nuclear Physics, Osaka University, Ibaraki, Osaka 567-0047 (Japan); Sugimura, H. [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, Naka, Ibaraki 319-1195 (Japan); Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Tanida, K., E-mail: tanida@phya.snu.ac.kr [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, Naka, Ibaraki 319-1195 (Japan); Department of Physics and Astronomy, Seoul National University, Seoul 151-747 (Korea, Republic of); Watabe, T. [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan)

    2014-11-01

    A single-sided silicon micro-strip detector (SSD) has been developed as a tracking detector for hadron experiments at J-PARC where secondary meson beams with intensities of up to 10{sup 8} Hz are available. The performance of the detector has been investigated and verified in a series of test beam experiments in the years 2009–2011. The hole mobility was deduced from the analysis of cluster events. The beam rate dependence was measured in terms of timing resolution, signal-to-noise ratio, and hit efficiency. This paper describes the detector with its read-out system, details of the test experiments, and discusses the performance achieved.

  1. A new strips tracker for the upgraded ATLAS ITk detector

    CERN Document Server

    David, Claire; The ATLAS collaboration

    2017-01-01

    The inner detector of the present ATLAS detector has been designed and developed to function in the environment of the present Large Hadron Collider (LHC). At the next-generation tracking detector proposed for the High Luminosity LHC (HL-LHC), the so-called ATLAS Phase-II Upgrade, the particle densities and radiation levels will be higher by as much as a factor of ten. The new detectors must be faster, they need to be more highly segmented, and covering more area. They also need to be more resistant to radiation, and they require much greater power delivery to the front-end systems. At the same time, they cannot introduce excess material which could undermine performance. For those reasons, the inner tracker of the ATLAS detector must be redesigned and rebuilt completely. The design of the ATLAS Upgrade inner tracker (ITk) has already been defined. It consists of several layers of silicon particle detectors. The innermost layers will be composed of silicon pixel sensors, and the outer layers will consist of s...

  2. Gamma Large Area Silicon Telescope (GLAST): Applying silicon strip detector technology to the detection of gamma rays in space

    International Nuclear Information System (INIS)

    Atwood, W.B.

    1993-06-01

    The recent discoveries and excitement generated by space satellite experiment EGRET (presently operating on Compton Gamma Ray Observatory -- CGRO) have prompted an investigation into modern detector technologies for the next generation space based gamma ray telescopes. The GLAST proposal is based on silicon strip detectors as the open-quotes technology of choiceclose quotes for space application: no consumables, no gas volume, robust (versus fragile), long lived, and self triggerable. The GLAST detector basically has two components: a tracking module preceding a calorimeter. The tracking module has planes of crossed strip (x,y) 300 μm pitch silicon detectors coupled to a thin radiator to measure the coordinates of converted electron-positron pairs. The gap between the layers (∼5 cm) provides a lever arm for track fitting resulting in an angular resolution of <0.1 degree at high energy. The status of this R ampersand D effort is discussed including details on triggering the instrument, the organization of the detector electronics and readout, and work on computer simulations to model this instrument

  3. SVX3: A deadtimeless readout chip for silicon strip detectors

    International Nuclear Information System (INIS)

    Zimmerman, T.; Huffman, T.; Srage, J.; Stroehmer, R.; Yarema, R.; Garcia-Sciveras, M.; Luo, L.; Milgrome, O.

    1997-12-01

    A new silicon strip readout chip called the SVX3 has been designed for the 720,000 channel CDF silicon upgrade at Fermilab. SVX3 incorporates an integrator, analog delay pipeline, ADC, and data sparsification for each of 128 identical channels. Many of the operating parameters are programmable via a serial bit stream, which allows the chip to be used under a variety of conditions. Distinct features of SVX3 include use of a backside substrate contact for optimal ground referencing, and the capability of simultaneous signal acquisition and digital readout allowing deadtimeless operation in the Fermilab Tevatron

  4. Parallel Configuration For Fast Superconducting Strip Line Detectors With Very Large Area In Time Of Flight Mass Spectrometry

    International Nuclear Information System (INIS)

    Casaburi, A.; Zen, N.; Suzuki, K.; Ohkubo, M.; Ejrnaes, M.; Cristiano, R.; Pagano, S.

    2009-01-01

    We realized a very fast and large Superconducting Strip Line Detector based on a parallel configuration of nanowires. The detector with size 200x200 μm 2 recorded a sub-nanosecond pulse width of 700 ps in FWHM (400 ps rise time and 530 ps relaxation time) for lysozyme monomers/multimers molecules accelerated at 175 keV in a Time of Flight Mass Spectrometer. This record is the best in the class of superconducting detectors and comparable with the fastest NbN superconducting single photon detector of 10x10 μm 2 . We succeeded in acquiring mass spectra as the first step for a scale-up to ∼mm pixel size for high throughput MS analysis, while keeping a fast response.

  5. Charge collection and depth sensing investigation on CZT drift strip detectors

    DEFF Research Database (Denmark)

    Kuvvetli, Irfan; Budtz-Jørgensen, Carl; Caroli, E.

    2010-01-01

    CZT drift strip detectors with Planar Transverse Field (PTF) configuration are suitable for high energy astrophysics instrumentation, where high efficiency, high energy and position resolution are required from the sensors. We report on experimental investigations on the DTU Space developed CZT...

  6. Proposed method of assembly for the BCD silicon strip vertex detector modules

    International Nuclear Information System (INIS)

    Lindenmeyer, C.

    1989-01-01

    The BCD Silicon strip Vertex Detector is constructed of 10 identical central region modules and 18 similar forward region modules. This memo describes a method of assembling these modules from individual silicon wafers. Each wafer is fitted with associated front end electronics and cables and has been tested to insure that only good wafers reach the final assembly stage. 5 figs

  7. Beam test measurements on GaAs strip and pixel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Albertz, D.; Braunschweig, W.; Breibach, J.; Graessel, D.; Kubicki, T.; Luebelsmeyer, K.; Rente, C.; Roeper, C.; Siedling, R.; Syben, O.; Tenbusch, F.; Toporowski, M.; Xiao, W.J. [Technische Hochschule Aachen (Germany). I. Physikalisches Institut

    1998-06-01

    GaAs strip and pixel detectors constructed in Aachen have been tested in a 1.4 GeV electron beam in Bonn and in a 5 GeV electron beam at DESY in February and May 1997. The strip detectors had a pitch of 50 {mu}m with a strip width of 25 {mu}m and were made of a 250 {mu}m thick Freiberger SI-GaAs wafer. The strip detectors included a punch-through bias structure and an integrated coupling capacitor. Additionally, an improved backside contact was formed, allowing a safe operation of the detector in a soft breakdown regime. Using the fast PreMux128 preamplifier multiplexer chip ({tau}{sub p}=50 ns) a signal-to-noise ratio of 13 was obtained at normal beam incidence for a bias voltage of 200 V, leading to a spatial resolution of 11 {mu}m with a simple COG algorithm. The 8 x 16 pixel array with a pixel size of 125 x 125 {mu}m{sup 2} was read out with the PreMux128 as well. With a double-metal technique, it was possible to bond the single-pixels linearly to the amplifier chip. The obtained signal-to-noise ratio of 30 in combination with a COG algorithm lead to the digital resolution value of 36 {mu}m for both pixel coordinates. (orig.) 10 refs.

  8. A Test-Bench for Measurement of Electrical Static Parameters of Strip Silicon Detectors

    CERN Document Server

    Golutvin, I A; Danilevich, V G; Dmitriev, A Yu; Elsha, V V; Zamiatin, Y I; Zubarev, E V; Ziaziulia, F E; Kozus, V I; Lomako, V M; Stepankov, D V; Khomich, A P; Shumeiko, N M; Cheremuhin, A E

    2003-01-01

    An automated test-bench for electrical parameters input control of the strip silicon detectors, used in the End-Cap Preshower detector of the CMS experiment, is described. The test-bench application allows one to solve a problem of silicon detectors input control in conditions of mass production - 1800 detectors over 2 years. The test-bench software is realized in Delphi environment and contains a user-friendly operator interface for measurement data processing and visualization as well as up-to-date facilities for MS-Windows used for the network database. High operating characteristics and reliability of the test-bench were confirmed while more than 800 detectors were tested. Some technical solutions applied to the test-bench could be useful for design and construction of automated facilities for electrical parameters measurements of the microstrip detectors input control.

  9. A test-bench for measurement of electrical static parameters of strip silicon detectors

    International Nuclear Information System (INIS)

    Golutvin, I.A.; Dmitriev, A.Yu.; Elsha, V.V.

    2003-01-01

    An automated test-bench for electrical parameters input control of the strip silicon detectors, used in the End-Cap Preshower detector of the CMS experiment, is described. The test-bench application allows one to solve a problem of silicon detectors input control in conditions of mass production - 1800 detectors over 2 years. The test-bench software is realized in Delphi environment and contains a user-friendly operator interface for data processing and visualization as well as up-to-date facilities for MS-Windows used for the network database. High operating characteristics and reliability of the test-bench were confirmed while more than 800 detectors were tested. Some technical solutions applied to the test-bench could be useful for design and construction of automated facilities for electrical parameters measurements of the microstrip detectors input control. (author)

  10. Detector and Front-end electronics for ALICE and STAR silicon strip layers

    CERN Document Server

    Arnold, L; Coffin, J P; Guillaume, G; Higueret, S; Jundt, F; Kühn, C E; Lutz, Jean Robert; Suire, C; Tarchini, A; Berst, D; Blondé, J P; Clauss, G; Colledani, C; Deptuch, G; Dulinski, W; Hu, Y; Hébrard, L; Kucewicz, W; Boucham, A; Bouvier, S; Ravel, O; Retière, F

    1998-01-01

    Detector modules consisting of Silicon Strip Detector (SSD) and Front End Electronics (FEE) assembly have been designed in order to provide the two outer layers of the ALICE Inner Tracker System (ITS) [1] as well as the outer layer of the STAR Silicon Vertex Tracker (SVT) [2]. Several prototypes have beenproduced and tested in the SPS and PS beam at CERN to validate the final design. Double-sided, AC-coupled SSD detectors provided by two different manufacturers and also a pair of single-sided SSD have been asssociated to new low-power CMOS ALICE128C ASIC chips in a new detector module assembly. The same detectors have also been associated to current Viking electronics for reference purpose. These prototype detector modules are described and some first results are presented.

  11. Application of a wedge strip anode in micro-pattern gaseous detectors

    International Nuclear Information System (INIS)

    Tian Yang; Yang Yigang; Li Yulan; Li Yuanjing

    2013-01-01

    The wedge strip anode (WSA) has been widely used in 2-D position-sensitive detectors. A circular WSA with an effective diameter of 52 mm is successfully coupled to a tripe gas electron multiplier (GEM) detector through a simple resistive layer. A spatial resolution of 440 μm (FWHM) is achieved for a 10 kVp X-ray using 1 atm Ar:CO 2 =70:30 gas. The simple electronics of only three channels makes it very useful in applications strongly requiring simple interface design, e.g. sealed tubes and high pressure detectors. (authors)

  12. Radiation damage measurements on CZT drift strip detectors

    DEFF Research Database (Denmark)

    Kuvvetli, Irfan; Budtz-Jørgensen, Carl; Korsbech, Uffe C C

    2003-01-01

    from 2 x 10(8) to 60 x 10(8) p(+)/cm(2). Even for the highest fluences, which had a dramatic effect on the spectroscopic performance, we were able to recover the detectors after an appropriate annealing procedure. The radiation damage was studied as a function of depth inside the detector material...... with the proton dose. The radiation contribution to the electron trapping was found to obey the following relation: (mutau(e)(-1))(rad) = (2.5+/-0.2) x 10(-7) x Phi (V/cm)(2) with the proton fluence, Phi in p(+)/cm(2). The trapping depth dependence, however, did not agree well with the damage profile calculated...

  13. Micro-strip Metal Foil Detectors for the Beam Profile Monitoring

    CERN Document Server

    Pugatch, V M; Fedorovitch, O A; Mikhailenko, A V; Prystupa, S V; Pylypchenko, Y

    2005-01-01

    The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. Fast particles hitting a metal strip initiate Secondary Electron Emission (SEE) which occurs at 10 - 50 nm surface layers of a strip. The SEE yield is measured by a sensitive Charge Integrator with built-in current-to-frequency converter (1 Hz per 1 fA). The MMFD (deposited onto the 20 μm thick Si-wafer) with 32 Al strips (10 μm wide, 32 μm pitch) has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator for Single-Event-Upset studies of the BEETLE micro-chip. Similar MMFD (0.5 μm thick Ni-strips) with totally removed Si-wafer (by plasma-chemistry, at the working area of 8 x 10 mm2) has been applied for the on-line X-ray BPM at the HASYLAB (DESY). The number of photons (11.3 GeV, mean X-ray energy 18 keV) producing out of a strip a single SEE was evaluated as (1.5 ±0.5)* 104. MMFD has demonstrated stable...

  14. ATLAS Tracker Upgrade: Silicon Strip Detectors and Modules for the SLHC

    CERN Document Server

    Minano, M

    2010-01-01

    It is foreseen to increase the luminosity of the Large Hadron Collider (LHC) at CERN by a factor ten, with the upgraded machine dubbed Super-LHC or sLHC. The ATLAS experiment will require a new tracker for sLHC operation. In order to cope with the increase in pile-up backgrounds at the higher luminosity, an all silicon detector is being designed. The new strip detector will use significantly shorter strips than the current SCT in order to minimise the occupancy. As the increased luminosity will mean a corresponding increase in radiation dose, a new generation of extremely radiation hard silicon detectors is required. Extensive R&D programmes are underway to develop silicon sensors with sufficient radiation hardness. In parallel, new front-end electronics and readout systems are being designed to cope with the higher data rates. The challenges of powering and cooling a very large strip detector will be discussed. Ideas on possible schemes for the layout and support mechanics will be shown.

  15. The ATLAS Tracker Upgrade Short Strips Detectors for the sLHC

    CERN Document Server

    Soldevila, U; Lacasta, C; Marti i García, S; Miñano, M

    2010-01-01

    It is foreseen to increase the luminosity of the Large Hadron Collider (LHC) at CERN around 2018 by about an order of magnitude, with the upgraded machine dubbed Super-LHC or sLHC. The ATLAS experiment will require a new tracker for SLHC operation. In order to cope with the order of magnitude increase in pile-up backgrounds at the higher luminosity, an all silicon detector is being designed. The new strip detector will use significantly shorter strips than the current SCT in order to minimise the occupancy. As the increased luminosity will mean a corresponding increase in radiation dose, a new generation of extremely radiation hard silicon detectors is required. A massive R&D programme is underway to develop silicon sensors with sufficient radiation hardness. New front-end electronics and readout systems are being designed to cope with the higher data rates. The challenges of powering and cooling a very large strip detector will be discussed. Ideas on possible schemes for the layout and support mechanics ...

  16. ATLAS Tracker Upgrade: Silicon Strip Detectors for the sLHC

    CERN Document Server

    Koehler, M

    2010-01-01

    It is foreseen to increase the luminosity of the Large Hadron Collider (LHC) at CERN by a factor ten, with the upgraded machine dubbed Super-LHC or sLHC. The ATLAS experiment will require a new tracker for sLHC operation. In order to cope with the increase in pile-up backgrounds at the higher luminosity, an all silicon detector is being designed. The new strip detector will use significantly shorter strips than the current SCT in order to minimise the occupancy. As the increased luminosity will mean a corresponding increase in radiation dose, a new generation of extremely radiation hard silicon detectors is required. Extensive R&D programmes are underway to develop silicon sensors with sufficient radiation hardness. In parallel, new front-end electronics and readout systems are being designed to cope with the higher data rates. The challenges of powering and cooling a very large strip detector will be discussed. Ideas on possible schemes for the layout and support mechanics will be shown. A key issue ...

  17. Atlas Tracker Upgrade: Silicon Strip Detectors and Modules for the SLHC

    CERN Document Server

    Minano, M

    2010-01-01

    It is foreseen to increase the luminosity of the Large Hadron Collider (LHC) at CERN by a significant factor, with the upgraded machine dubbed Super-LHC. The ATLAS experiment will require a new tracker for Super-LHC operation. In order to cope with the increase in pile-up backgrounds at the higher luminosity, an all silicon detector is being designed. The new strip detector will use significantly shorter strips than the current SCT in order to minimise the occupancy. As the increased luminosity will imply a corresponding increase in radiation dose, a new generation of extremely radiation hard silicon detectors is required. Extensive R&D programmes are underway to develop silicon sensors with sufficient radiation hardness. In parallel, new front-end electronics and readout systems are being designed to cope with the higher data rates. The challenges of powering and cooling a very large strip detector will be discussed. Ideas on possible schemes for the layout and support mechanics will be shown.

  18. ATLAS Tracker Upgrade: Silicon Strip Detectors and Modules for the sLHC

    International Nuclear Information System (INIS)

    Lefebvre, Michel; Minano Moya, Mercedes

    2010-01-01

    It is foreseen to increase the luminosity of the Large Hadron Collider (LHC) at CERN by a factor ten, with the upgraded machine dubbed Super-LHC or sLHC. The ATLAS experiment will require a new tracker for sLHC operation. In order to cope with the increase in pile-up backgrounds at the higher luminosity, an all silicon detector is being designed. The new strip detector will use significantly shorter strips than the current SCT in order to minimise the occupancy. As the increased luminosity will mean a corresponding increase in radiation dose, a new generation of extremely radiation hard silicon detectors is required. Extensive R programmes are underway to develop silicon sensors with sufficient radiation hardness. In parallel, new front-end electronics and readout systems are being designed to cope with the higher data rates. The challenges of powering and cooling a very large strip detector will be discussed. Ideas on possible schemes for the layout and support mechanics will be shown. (authors)

  19. Hadron-therapy beam monitoring: Towards a new generation of ultra-thin p-type silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bouterfa, M.; Aouadi, K. [Inst. of Information and Communication Technologies, Electronics and Applied Mathematics ICTEAM, Universite Catholique de Louvain, 1348 Louvain-la-Neuve (Belgium); Bertrand, D. [Particle Therapy Dept., Ion Beam Application IBA, 1348 Louvain-la-Neuve (Belgium); Olbrechts, B.; Delamare, R. [Inst. of Information and Communication Technologies, Electronics and Applied Mathematics ICTEAM, Universite Catholique de Louvain, 1348 Louvain-la-Neuve (Belgium); Raskin, J. P.; Gil, E. C. [Institut de Recherche en Mathematique et Physique IRMP, Universite Catholique de Louvain, 1348 Louvain-la-Neuve (Belgium); Flandre, D. [Inst. of Information and Communication Technologies, Electronics and Applied Mathematics ICTEAM, Universite Catholique de Louvain, 1348 Louvain-la-Neuve (Belgium)

    2011-07-01

    Hadron-therapy has gained increasing interest for cancer treatment especially within the last decade. System commissioning and quality assurance procedures impose to monitor the particle beam using 2D dose measurements. Nowadays, several monitoring systems exist for hadron-therapy but all show a relatively high influence on the beam properties: indeed, most devices consist of several layers of materials that degrade the beam through scattering and energy losses. For precise treatment purposes, ultra-thin silicon strip detectors are investigated in order to reduce this beam scattering. We assess the beam size increase provoked by the Multiple Coulomb Scattering when passing through Si, to derive a target thickness. Monte-Carlo based simulations show a characteristic scattering opening angle lower than 1 mrad for thicknesses below 20 {mu}m. We then evaluated the fabrication process feasibility. We successfully thinned down silicon wafers to thicknesses lower than 10 {mu}m over areas of several cm{sup 2}. Strip detectors are presently being processed and they will tentatively be thinned down to 20 {mu}m. Moreover, two-dimensional TCAD simulations were carried out to investigate the beam detector performances on p-type Si substrates. Additionally, thick and thin substrates have been compared thanks to electrical simulations. Reducing the pitch between the strips increases breakdown voltage, whereas leakage current is quite insensitive to strips geometrical configuration. The samples are to be characterized as soon as possible in one of the IBA hadron-therapy facilities. For hadron-therapy, this would represent a considerable step forward in terms of treatment precision. (authors)

  20. Hadron-therapy beam monitoring: Towards a new generation of ultra-thin p-type silicon strip detectors

    International Nuclear Information System (INIS)

    Bouterfa, M.; Aouadi, K.; Bertrand, D.; Olbrechts, B.; Delamare, R.; Raskin, J. P.; Gil, E. C.; Flandre, D.

    2011-01-01

    Hadron-therapy has gained increasing interest for cancer treatment especially within the last decade. System commissioning and quality assurance procedures impose to monitor the particle beam using 2D dose measurements. Nowadays, several monitoring systems exist for hadron-therapy but all show a relatively high influence on the beam properties: indeed, most devices consist of several layers of materials that degrade the beam through scattering and energy losses. For precise treatment purposes, ultra-thin silicon strip detectors are investigated in order to reduce this beam scattering. We assess the beam size increase provoked by the Multiple Coulomb Scattering when passing through Si, to derive a target thickness. Monte-Carlo based simulations show a characteristic scattering opening angle lower than 1 mrad for thicknesses below 20 μm. We then evaluated the fabrication process feasibility. We successfully thinned down silicon wafers to thicknesses lower than 10 μm over areas of several cm 2 . Strip detectors are presently being processed and they will tentatively be thinned down to 20 μm. Moreover, two-dimensional TCAD simulations were carried out to investigate the beam detector performances on p-type Si substrates. Additionally, thick and thin substrates have been compared thanks to electrical simulations. Reducing the pitch between the strips increases breakdown voltage, whereas leakage current is quite insensitive to strips geometrical configuration. The samples are to be characterized as soon as possible in one of the IBA hadron-therapy facilities. For hadron-therapy, this would represent a considerable step forward in terms of treatment precision. (authors)

  1. Evaluation of the data of the HERA-B vertex detector with regards to the physical properties of the applied silicon strip counters

    International Nuclear Information System (INIS)

    Wagner, W.

    1999-01-01

    The HERA-B experiment at the DESY laboratory in Hamburg is dedicated to measuring CP-violation in the decays of neutral B-mesons. The primary purpose of the experiment in the measurement of the CP-asymmetry in the decay channel B 0 → J/ψK S 0 . In order to identify the B-mesons and to determine the time-dependent asymmetry, the decay length anti Δ anti l of the B-mesons must be measured to an accuracy of σ Δl ≤ 500 μm. To achieve this aim, HERA-B has a vertex detector which is based on double-sided silicon strip detectors mounted in a Roman pot system. One important specification of the vertex detector is to allow independent tracking with an efficiency above 95%. Therefore, it is required to select hits on the strip detectors with an efficiency above 99% and optimize the suppression of noise. This thesis describes a detailed investigation of the behaviour of the silicon strip detectors used in the vertex detector. The first part presents measurements performed in the laboratory using a tunable infrared dye laser to simulate the passage of charged particles through the detector. This includes measurements of the charge division between adjacent readout strips and mapping of the detector depletion. The results of the measurements agree excellently with the predictions from a detailed model calculation carried out in this thesis. The second part of the thesis the analysis of data recorded with the HERA-B vertex detector during the commissioning run of spring 1999. The analysis focusses on the investigation of cluster shapes and cluster sizes. In particular, the dependence of these distributions from the selection cuts is analyzed. Additionally, the differences between the two detector designs used, p-spray and p-stop detectors with intermediate strip or without respectively, are worked out. The measured distributions agree very well with the predictions from a model calculation taking all relevant detector parameters into account. The results of the data

  2. Commissioning of the scatter component of a Compton camera consisting of a stack of Si strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Liprandi, S.; Marinsek, T.; Bortfeldt, J.; Lang, C.; Lutter, R.; Dedes, G.; Parodi, K.; Thirolf, P.G. [LMU Munich, Garching (Germany); Aldawood, S. [LMU Munich, Garching (Germany); King Saud University, Riyadh (Saudi Arabia); Maier, L.; Gernhaeuser, R. [TU Munich, Garching (Germany); Kolff, H. van der [LMU Munich, Garching (Germany); TU Delft (Netherlands); Castelhano, I. [LMU Munich, Garching (Germany); University of Lisbon, Lisbon (Portugal); Schaart, D.R. [TU Delft (Netherlands)

    2015-07-01

    At LMU Munich in Garching a Compton camera is presently being developed aiming at the range verification of proton (or ion) beams for hadron therapy via imaging of prompt γ rays from nuclear reactions in the tissue. The poster presentation focuses on the characterization of the scatter component of the Compton camera, consisting of a stack of six double-sided Si strip detectors (50 x 50 mm{sup 2}, 0.5 mm thick, 128 strips/side). The overall 1536 electronics channels are processed by a readout system based on the GASSIPLEX ASIC chip, feeding into a VME-based data acquisition system. The status of the offline and online characterization studies is presented.

  3. Degradation of charge sharing after neutron irradiation in strip silicon detectors with different geometries

    International Nuclear Information System (INIS)

    Casse, G.; Dervan, P.; Forshaw, D.; Greenall, A.; Huse, T.; Tsurin, I.; Wormald, M.

    2013-01-01

    The aim of the CERN/RD50 collaboration is the improvement of the radiation tolerance of semiconductor detectors for future experiments at high-luminosity colliders. In the RD50 framework, evidence of enhanced signal charge in severely irradiated silicon detectors (diodes, segmented planar and 3D devices) was found. The underlying mechanism was labelled charge multiplication. This has been one of the most exciting results from the research activity of RD50 because it could allow for a greatly extended radiation tolerance, if the mechanism is to be found controllable and tuneable. The charge multiplication mechanism is governed by impact ionisation from electrons drifting in high electric field. The electric field profile is influenced by the geometry of the implanted electrodes. In order to investigate the influence of the diode implantation geometry on charge multiplication, the RD50 collaboration has commissioned the production of miniature microstrip silicon sensors with various choices of strip pitch and strip width over pitch (w/p) ratios. Moreover, some of the sensors were produced interleaving readout strips with dummy intermediate ones in order to modify the electric field profile. These geometrical solutions can influence both charge multiplication and charge sharing between adjacent strips. The initial results of this study are here presented

  4. Design and characterization of integrated front-end transistors in a micro-strip detector technology

    International Nuclear Information System (INIS)

    Simi, G.; Angelini, C.; Batignani, G.; Bettarini, S.; Bondioli, M.; Boscardin, M.; Bosisio, L.; Dalla Betta, G.-F.; Dittongo, S.; Forti, F.; Giorgi, M.; Gregori, P.; Manghisoni, M.; Morganti, M.; U. Pignatel, G.; Ratti, L.; Re, V.; Rizzo, G.; Speziali, V.; Zorzi, N.

    2002-01-01

    We present the developments in a research program aimed at the realization of silicon micro-strip detectors with front-end electronics integrated in a high resistivity substrate to be used in high-energy physics, space and medical/industrial imaging applications. We report on the fabrication process developed at IRST (Trento, Italy), the characterization of the basic wafer parameters and measurements of the relevant working characteristics of the integrated transistors and related test structures

  5. Prototyping of Silicon Strip Detectors for the Inner Tracker of the ALICE Experiment

    CERN Document Server

    Sokolov, Oleksiy

    2006-01-01

    The ALICE experiment at CERN will study heavy ion collisions at a center-of-mass energy 5.5∼TeV per nucleon. Particle tracking around the interaction region at radii r<45 cm is done by the Inner Tracking System (ITS), consisting of six cylindrical layers of silicon detectors. The outer two layers of the ITS use double-sided silicon strip detectors. This thesis focuses on testing of these detectors and performance studies of the detector module prototypes at the beam test. Silicon strip detector layers will require about 20 thousand HAL25 front-end readout chips and about 3.5 thousand hybrids each containing 6 HAL25 chips. During the assembly procedure, chips are bonded on a patterned TAB aluminium microcables which connect to all the chip input and output pads, and then the chips are assembled on the hybrids. Bonding failures at the chip or hybrid level may either render the component non-functional or deteriorate its the performance such that it can not be used for the module production. After each bond...

  6. Count rate performance of a silicon-strip detector for photon-counting spectral CT

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X., E-mail: olivia@mi.physics.kth.se; Grönberg, F.; Sjölin, M.; Karlsson, S.; Danielsson, M.

    2016-08-11

    A silicon-strip detector is developed for spectral computed tomography. The detector operates in photon-counting mode and allows pulse-height discrimination with 8 adjustable energy bins. In this work, we evaluate the count-rate performance of the detector in a clinical CT environment. The output counts of the detector are measured for x-ray tube currents up to 500 mA at 120 kV tube voltage, which produces a maximum photon flux of 485 Mphotons/s/mm{sup 2} for the unattenuated beam. The corresponding maximum count-rate loss of the detector is around 30% and there are no saturation effects. A near linear relationship between the input and output count rates can be observed up to 90 Mcps/mm{sup 2}, at which point only 3% of the input counts are lost. This means that the loss in the diagnostically relevant count-rate region is negligible. A semi-nonparalyzable dead-time model is used to describe the count-rate performance of the detector, which shows a good agreement with the measured data. The nonparalyzable dead time τ{sub n} for 150 evaluated detector elements is estimated to be 20.2±5.2 ns.

  7. Count rate performance of a silicon-strip detector for photon-counting spectral CT

    Science.gov (United States)

    Liu, X.; Grönberg, F.; Sjölin, M.; Karlsson, S.; Danielsson, M.

    2016-08-01

    A silicon-strip detector is developed for spectral computed tomography. The detector operates in photon-counting mode and allows pulse-height discrimination with 8 adjustable energy bins. In this work, we evaluate the count-rate performance of the detector in a clinical CT environment. The output counts of the detector are measured for x-ray tube currents up to 500 mA at 120 kV tube voltage, which produces a maximum photon flux of 485 Mphotons/s/mm2 for the unattenuated beam. The corresponding maximum count-rate loss of the detector is around 30% and there are no saturation effects. A near linear relationship between the input and output count rates can be observed up to 90 Mcps/mm2, at which point only 3% of the input counts are lost. This means that the loss in the diagnostically relevant count-rate region is negligible. A semi-nonparalyzable dead-time model is used to describe the count-rate performance of the detector, which shows a good agreement with the measured data. The nonparalyzable dead time τn for 150 evaluated detector elements is estimated to be 20.2±5.2 ns.

  8. Output factor determination for dose measurements in axial and perpendicular planes using a silicon strip detector

    Science.gov (United States)

    Abou-Haïdar, Z.; Bocci, A.; Alvarez, M. A. G.; Espino, J. M.; Gallardo, M. I.; Cortés-Giraldo, M. A.; Ovejero, M. C.; Quesada, J. M.; Arráns, R.; Prieto, M. Ruiz; Vega-Leal, A. Pérez; Nieto, F. J. Pérez

    2012-04-01

    In this work we present the output factor measurements of a clinical linear accelerator using a silicon strip detector coupled to a new system for complex radiation therapy treatment verification. The objective of these measurements is to validate the system we built for treatment verification. The measurements were performed at the Virgin Macarena University Hospital in Seville. Irradiations were carried out with a Siemens ONCOR™ linac used to deliver radiotherapy treatment for cancer patients. The linac was operating in 6 MV photon mode; the different sizes of the fields were defined with the collimation system provided within the accelerator head. The output factor was measured with the silicon strip detector in two different layouts using two phantoms. In the first, the active area of the detector was placed perpendicular to the beam axis. In the second, the innovation consisted of a cylindrical phantom where the detector was placed in an axial plane with respect to the beam. The measured data were compared with data given by a commercial treatment planning system. Results were shown to be in a very good agreement between the compared set of data.

  9. Charge collection mapping of a novel ultra-thin silicon strip detector for hadrontherapy beam monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bouterfa, Mohamed, E-mail: mohamed.bouterfa@uclouvain.be [ICTEAM Institute, Universite catholique de Louvain, Louvain-la-Neuve (Belgium); Alexandre, Geoffrey; Cortina Gil, Eduardo [IRPM Institute, Universite catholique de Louvain, Louvain-la-Neuve (Belgium); Flandre, Denis [ICTEAM Institute, Universite catholique de Louvain, Louvain-la-Neuve (Belgium)

    2013-12-21

    In precise hadrontherapy treatments, the particle beam must be monitored in real time without being degraded. Silicon strip detectors have been fabricated over an area as large as 4.5×4.5 cm{sup 2} with ultra low thickness of 20μm. These offer the following considerable advantages: significantly reduced beam scattering, higher radiation hardness which leads to improved detector lifetime, and much better collection efficiency. In a previous work, the novel sensor has been described and a global macroscopic dosimetry characterization has been proposed. This provides practical information for the detector daily use but not about the local microscopic knowledge of the sensor. This work therefore presents a micrometric-accuracy charge-collection characterization of this new generation of ultra-thin silicon strip detectors. This goal is reached thanks to a 1060 nm-wavelength micrometric-sized laser that can be positioned relatively to the sensor with a submicron precision for the three different axes. This study gives a much better knowledge of the inefficient areas of the sensor and allows therefore optimization for future designs.

  10. First testbeam results of prototype modules for the upgrade of the ATLAS strip tracking detector

    CERN Document Server

    Kuehn, Susanne; The ATLAS collaboration

    2016-01-01

    The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential of the LHC through a sizeable increase in the luminosity, totalling 1x1035cm-2s-1 after 10 years of operation. A consequence of this increased luminosity is the expected radiation damage at a integrated luminosity of 3000fb-1, requiring the tracking detectors to withstand hadron equivalences to over 1x1016 1 MeV neutron equivalent per cm2. With the addition of increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk), which will consist of both strip and pixellated silicon detectors. The silicon strip tracker exploits the concept of modularity. Fast readout electronics, deploying 130nm CMOS front-end electronics is glued on top of a silicon sensor. These so-called modules are glued on carbon structures and will span about 200m2 of active area. A broad R&D program is ongoing to develop and prototype many detector components. The modu...

  11. Electromagnetic noise studies in a silicon strip detector, used as part of a luminosity monitor at LEP

    Science.gov (United States)

    Ødegaard, Trygve; Tafjord, Harald; Buran, Torleiv

    1995-02-01

    As part of the luminosity monitor, SAT, in the DELPHI [1] experiment at CERN's Large Electron Positron collider, a tracking detector constructed from silicon strip detector elements was installed in front of an electromagnetic calorimeter. The luminosity was measured by counting the number of Bhabha events at the interaction point of the electron and the positron beans. The tracking detector reconstructs from the interaction point and the calorimeter measures the corresponding particles' energies. The SAT Tracker [2] consists of 504 silicon strip detectors. The strips are DC-coupled to CMOS VLSI-chips, baptized Balder [3,4]. The chip performs amplification, zero-suppression, digitalisation, and multiplexing. The requirements of good space resolution and high efficiency put strong requirements on noise control. A short description of the geometry and the relevant circuit layout is given. We describe the efforts made to minimise the electromagnetic noise in the detector and present some numbers of the noise level using various techniques.

  12. Web-Based Cathode Strip Chamber Data Display

    CERN Multimedia

    Firmansyah, M

    2013-01-01

    Cathode Strip Chamber (CSC) is a detector that uses gas and high electric field to detect particles. When a particle goes through CSC, it will ionize gas particles and generate electric signal in the anode and cathode of the detector. Analysis of the electric signal data can help physicists to reconstruct path of the particles and determine what happen inside the detector. Using data display, analysis of CSC data becomes easier. One can determine which data is interesting, unusual, or maybe only contain noise.\

  13. Application of a double-sided silicon-strip detector as a differential pumping barrier for NESR experiments at FAIR

    NARCIS (Netherlands)

    Streicher, B.; Egelhof, P.; Ilieva, S.; Kalantar-Nayestanaki, N.; Kollmus, H.; Kroell, Th; Mutterer, M.; von Schmid, M.; Traeger, M.

    2011-01-01

    The presented work focuses on the development of a differential pumping system using double-sided silicon-strip detectors to separate the ultra-high vacuum of a storage ring from subsequent detectors and outgassing components placed in an auxiliary vacuum. Such a technical concept will give the

  14. A Low Mass On-Chip Readout Scheme for Double-Sided Silicon Strip Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Irmler, C., E-mail: christian.irmler@oeaw.ac.at [HEPHY Vienna – Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, A-1050 Vienna (Austria); Bergauer, T.; Frankenberger, A.; Friedl, M.; Gfall, I. [HEPHY Vienna – Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, A-1050 Vienna (Austria); Higuchi, T. [University of Tokyo, Kavli Institute for Physics and Mathematics of the Universe, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8583 (Japan); Ishikawa, A. [Tohoku University, Department of Physics, Aoba Aramaki Aoba-ku, Sendai 980-8578 (Japan); Joo, C. [Seoul National University, High Energy Physics Laboratory, 25-107 Shinlim-dong, Kwanak-gu, Seoul 151-742 (Korea, Republic of); Kah, D.H.; Kang, K.H. [Kyungpook National University, Department of Physics, 1370 Sankyuk Dong, Buk Gu, Daegu 702-701 (Korea, Republic of); Rao, K.K. [Tata Institute of Fundamental Research, Experimental High Energy Physics Group, Homi Bhabha Road, Mumbai 400 005 (India); Kato, E. [Tohoku University, Department of Physics, Aoba Aramaki Aoba-ku, Sendai 980-8578 (Japan); Mohanty, G.B. [Tata Institute of Fundamental Research, Experimental High Energy Physics Group, Homi Bhabha Road, Mumbai 400 005 (India); Negishi, K. [Tohoku University, Department of Physics, Aoba Aramaki Aoba-ku, Sendai 980-8578 (Japan); Onuki, Y.; Shimizu, N. [University of Tokyo, Department of Physics, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Tsuboyama, T. [KEK, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Valentan, M. [HEPHY Vienna – Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, A-1050 Vienna (Austria)

    2013-12-21

    B-factories like the KEKB in Tsukuba, Japan, operate at relatively low energies and thus require detectors with very low material budget in order to minimize multiple scattering. On the other hand, front-end chips with short shaping time like the APV25 have to be placed as close to the sensor strips as possible to reduce the capacitive load, which mainly determines the noise figure. In order to achieve both – minimal material budget and low noise – we developed a readout scheme for double-sided silicon detectors, where the APV25 chips are placed on a flexible circuit, which is glued onto the top side of the sensor. The bottom-side strips are connected by two flexible circuits, which are bent around the edge of the sensor. This so-called “Origami” design will be utilized to build the Silicon Vertex Detector of the Belle II experiment, which will consist of four layers made from ladders with up to five double-sided silicon strip sensors in a row. Each ladder will be supported by two ribs made of a carbon fiber and Airex foam core sandwich. The heat dissipated by the front-end chips will be removed by a highly efficient two-phase CO{sub 2} system. Thanks to the Origami concept, all APV25 chips are aligned in a row and thus can be cooled by a single thin cooling pipe per ladder. We present the concept and the assembly procedure of the Origami chip-on-sensor modules.

  15. A Low Mass On-Chip Readout Scheme for Double-Sided Silicon Strip Detectors

    International Nuclear Information System (INIS)

    Irmler, C.; Bergauer, T.; Frankenberger, A.; Friedl, M.; Gfall, I.; Higuchi, T.; Ishikawa, A.; Joo, C.; Kah, D.H.; Kang, K.H.; Rao, K.K.; Kato, E.; Mohanty, G.B.; Negishi, K.; Onuki, Y.; Shimizu, N.; Tsuboyama, T.; Valentan, M.

    2013-01-01

    B-factories like the KEKB in Tsukuba, Japan, operate at relatively low energies and thus require detectors with very low material budget in order to minimize multiple scattering. On the other hand, front-end chips with short shaping time like the APV25 have to be placed as close to the sensor strips as possible to reduce the capacitive load, which mainly determines the noise figure. In order to achieve both – minimal material budget and low noise – we developed a readout scheme for double-sided silicon detectors, where the APV25 chips are placed on a flexible circuit, which is glued onto the top side of the sensor. The bottom-side strips are connected by two flexible circuits, which are bent around the edge of the sensor. This so-called “Origami” design will be utilized to build the Silicon Vertex Detector of the Belle II experiment, which will consist of four layers made from ladders with up to five double-sided silicon strip sensors in a row. Each ladder will be supported by two ribs made of a carbon fiber and Airex foam core sandwich. The heat dissipated by the front-end chips will be removed by a highly efficient two-phase CO 2 system. Thanks to the Origami concept, all APV25 chips are aligned in a row and thus can be cooled by a single thin cooling pipe per ladder. We present the concept and the assembly procedure of the Origami chip-on-sensor modules

  16. LHCb - SALT, a dedicated readout chip for strip detectors in the LHCb Upgrade experiment

    CERN Multimedia

    Swientek, Krzysztof Piotr

    2015-01-01

    Silicon strip detectors in the upgraded Tracker of LHCb experiment will require a new readout 128-channel ASIC called SALT. It will extract and digitise analogue signals from the sensor, perform digital processing and transmit serial output data. SALT is designed in CMOS 130 nm process and uses a novel architecture comprising of analogue front-end and ultra-low power ($<$0.5 mW) fast (40 MSps) sampling 6-bit ADC in each channel. A prototype of first 8-channel version of SALT chip, comprising all important functionalities, was submitted. Its design and possibly first tests results will be presented.

  17. On the behavior of ion implanted silicon strip detectors in high intensity low energy heavy ion beam experiments

    CERN Document Server

    Bradfield, W; Parker, P D; Visser, D W

    2002-01-01

    In a recent investigation of the development of leakage currents in Silicon Strip Detectors used in experiments with high intensity stable beams, anomalous behavior was observed. Over a very short period of time the leakage current rose to levels that could be damaging to the detectors. A discussion of this evidence and how the problem was solved, with a viable model, will be given, leading to guidelines for use of such detectors in a stable beam environment.

  18. Mechanical studies towards a silicon micro-strip super module for the ATLAS inner detector upgrade at the high luminosity LHC

    International Nuclear Information System (INIS)

    Barbier, G; Cadoux, F; Clark, A; Favre, Y; Ferrere, D; Gonzalez-Sevilla, S; Iacobucci, G; Marra, D La; Perrin, E; Seez, W; Endo, M; Hanagaki, K; Hara, K; Ikegami, Y; Nakamura, K; Takubo, Y; Terada, S; Jinnouchi, O; Nishimura, R; Takashima, R

    2014-01-01

    It is expected that after several years of data-taking, the Large Hadron Collider (LHC) physics programme will be extended to the so-called High-Luminosity LHC, where the instantaneous luminosity will be increased up to 5 × 10 34  cm −2  s −1 . For the general-purpose ATLAS experiment at the LHC, a complete replacement of its internal tracking detector will be necessary, as the existing detector will not provide the required performance due to the cumulated radiation damage and the increase in the detector occupancy. The baseline layout for the new ATLAS tracker is an all-silicon-based detector, with pixel sensors in the inner layers and silicon micro-strip detectors at intermediate and outer radii. The super-module (SM) is an integration concept proposed for the barrel strip region of the future ATLAS tracker, where double-sided stereo silicon micro-strip modules (DSM) are assembled into a low-mass local support (LS) structure. Mechanical aspects of the proposed LS structure are described

  19. Degradation of charge sharing after neutron irradiation in strip silicon detectors with different geometries

    CERN Document Server

    Casse, G

    2013-01-01

    The aim of the CERN/RD50 collaboration is the improvement of the radiation tolerance of semiconductor detectors for future experiments at high-luminosity colliders. In the RD50 framework, evidence of enhanced signal charge in severely irradiated silicon detectors (diodes, segmented planar and 3D devices) was found. The underlying mechanism was labelled charge multiplication. This has been one of the most exciting results from the research activity of RD50 because it could allow for a greatly extended radiation tolerance, if the mechanism is to be found controllable and tuneable. The charge multiplication mechanism is governed by impact ionisation from electrons drifting in high electric field. The electric field profile is influenced by the geometry of the implanted electrodes. In order to investigate the influence of the diode implantation geometry on charge multiplication, the RD50 collaboration has commissioned the production of miniature microstrip silicon sensors with various choices of strip pitch and s...

  20. CMOS front end analog signal readout chip for Si-strip/PIN detectors

    International Nuclear Information System (INIS)

    Chandratre, V.B.; Sardesai, S.V.; Kataria, S.K.

    2001-01-01

    The paper presents the design of an 8-channel front-end chip for Si-strip detectors, ranging in capacitance from 1 to 30 pf. Each channel consists of a charge amplifier, a shaper amplifier (CR-RC 3 ) and a track-hold stage. The channel outputs are connected to an analog multiplexer which is controlled by an external clock for serial readout. The peaking time is adjustable over 250ns-2us in four fixed steps by external control. There is provision for changing gain low/high. A derivative of the chip is also developed for dosimeter application that uses small area diodes as detectors. The circuit has a power dissipation of 6 MW per channel and is designed to fabricate in 1.2um CMOS technology. The Opf noise is ∼400e. The design approach is presented and the results of simulation are shown. (author)

  1. A Silicon Strip Detector for the Phase II High Luminosity Upgrade of the ATLAS Detector at the Large Hadron Collider

    CERN Document Server

    INSPIRE-00425747; McMahon, Stephen J

    2015-01-01

    ATLAS is a particle physics experiment at the Large Hadron Collider (LHC) that detects proton-proton collisions at a centre of mass energy of 14 TeV. The Semiconductor Tracker is part of the Inner Detector, implemented using silicon microstrip detectors with binary read-out, providing momentum measurement of charged particles with excellent resolution. The operation of the LHC and the ATLAS experiment started in 2010, with ten years of operation expected until major upgrades are needed in the accelerator and the experiments. The ATLAS tracker will need to be completely replaced due to the radiation damage and occupancy of some detector elements and the data links at high luminosities. These upgrades after the first ten years of operation are named the Phase-II Upgrade and involve a re-design of the LHC, resulting in the High Luminosity Large Hadron Collider (HL-LHC). This thesis presents the work carried out in the testing of the ATLAS Phase-II Upgrade electronic systems in the future strips tracker a...

  2. Silicon strip tracking detector development and prototyping for the Phase-2 Upgrade of the ATLAS experiment

    CERN Document Server

    Kuehn, Susanne; The ATLAS collaboration

    2015-01-01

    In about ten years from now, the Phase-2 upgrade of the LHC is planned. This will result in a severe radiation dose and high particle rates for the multipurpose exeperiments because of a foreseen luminosity of ten times higher the LHC design luminosity. Several detector components will have to be upgraded in the experiments. In the ATLAS experiment the current inner detector will be replaced by an all silicon tracking detector aiming for high performance. The poster will present the development and the latest prototyping of the upgrade silicon strip tracking detector. Its layout foresees low mass and modular double-sided structures for the barrel and forward region. Silicon sensors and readout electronics, so-called modules, are planned to be assembled double-sided on larger carbon-core structures. The modularity allows assembly and testing at multiple sites. Many components need to be developed and their prototyping towards full-size components is ongoing. New developments and test results will be presented....

  3. The honeycomb strip chamber: A two coordinate and high precision muon detector

    Energy Technology Data Exchange (ETDEWEB)

    Tolsma, H.P.T.

    1996-04-19

    This thesis describes the construction and performance of the Honeycomb Strip Chamber (HSC). The HSC offers several advantages with respect to classical drift chambers and drift tubes. The main features of the HSC are: -The detector offers the possibility of simultaneous readout of two orthogonal coordinates with approximately the same precision. - The HSC technology is optimised for mass production. This means that the design is modular (monolayers) and automisation of most of the production steps is possible (folding and welding machines). - The technology is flexible. The cell diameter can easily be changed from a few millimetres to at least 20 mm by changing the parameters in the computer programme of the folding machine. The number of monolayers per station can be chosen freely to the demands of the experiment. -The honeycomb structure gives the detector stiffness and makes it self supporting. This makes the technology a very transparent one in terms of radiation length which is important to prevent multiple scattering of high energetic muons. - The dimensions of the detector are defined by high precision templates. Those templates constrain for example the overall tolerance on the wire positions to 20 {mu}m rms. Reproduction of the high precision assembly of the detector is thus guaranteed. (orig.).

  4. The honeycomb strip chamber: A two coordinate and high precision muon detector

    International Nuclear Information System (INIS)

    Tolsma, H.P.T.

    1996-01-01

    This thesis describes the construction and performance of the Honeycomb Strip Chamber (HSC). The HSC offers several advantages with respect to classical drift chambers and drift tubes. The main features of the HSC are: -The detector offers the possibility of simultaneous readout of two orthogonal coordinates with approximately the same precision. - The HSC technology is optimised for mass production. This means that the design is modular (monolayers) and automisation of most of the production steps is possible (folding and welding machines). - The technology is flexible. The cell diameter can easily be changed from a few millimetres to at least 20 mm by changing the parameters in the computer programme of the folding machine. The number of monolayers per station can be chosen freely to the demands of the experiment. -The honeycomb structure gives the detector stiffness and makes it self supporting. This makes the technology a very transparent one in terms of radiation length which is important to prevent multiple scattering of high energetic muons. - The dimensions of the detector are defined by high precision templates. Those templates constrain for example the overall tolerance on the wire positions to 20 μm rms. Reproduction of the high precision assembly of the detector is thus guaranteed. (orig.)

  5. Measurements on GaAs strip and pixel detectors in a 50 GeV pion beam

    Energy Technology Data Exchange (ETDEWEB)

    Syben, O. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Arbabi, S. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Braunschweig, W. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Breibach, J. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Chu, Z. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Karpinski, W. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Krais, R. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Kubicki, Th. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Luebelsmeyer, K. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Rente, C. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Siedling, R. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Tenbusch, F. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Toporowski, M. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Wittmer, B. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Xiao, W.J. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.

    1997-04-01

    GaAs strip and pixel detectors constructed in Aachen have been tested at CERN in a 50 GeV pion beam in September 1995 in collaboration with the CMS Tracker group. The strip detectors had a pitch of 100 {mu}m and were made of a 250 {mu}m thick Freiberger SI-GaAs wafer. The three strip detectors had a strip width of 25, 50 and 75 {mu}m, respectively. Using the fast PreMux128 preamplifier multiplexer chip ({tau}{sub p}=50 ns) a signal to noise ratio of 15 was obtained for the widest strips at normal beam incidence for a bias voltage of 170 V. The 8 x 8 pixel arrays with a pixel size of 1 x 1 mm{sup 2} and 0.5 x 0.5 mm{sup 2}, respectively, were read out with the PreMux128 as well. Here a signal of 12500e{sup -} was obtained for both detectors, leading to a maximum signal to noise ratio of 20 at perpendicular beam incidence and 170 V bias voltage. (orig.).

  6. Radiation tolerance of oxygenated n-strip read-out detectors

    CERN Document Server

    Allport, P P; Greenall, A

    2003-01-01

    Following earlier work on 'oxygenated' detectors in terms of charge collection efficiencies after proton irradiation, full-size detectors for the LHC have been processed with n-side read-out on oxygen enhanced n-type silicon substrates. Two hundred-micron-thick detectors have been inhomogeneously irradiated up to doses of 7 multiplied by 10**1**4p/cm**2 using 24 GeV protons from the CERN PS. Results are presented on the charge collection efficiencies as a function of operating voltage for regions of the detectors irradiated to different doses, using LHC speed analogue read-out electronics. The measurements confirm the expectations which led to our original proposal of such detectors which are now being envisaged for the silicon-based detector systems at the LHC designed to withstand the greatest doses. The possibilities for survival at an upgraded luminosity LHC (Super-LHC) are also briefly discussed.

  7. Prototyping of petalets for the Phase-II upgrade of the silicon strip tracking detector of the ATLAS experiment

    Science.gov (United States)

    Kuehn, S.; Benítez, V.; Fernández-Tejero, J.; Fleta, C.; Lozano, M.; Ullán, M.; Lacker, H.; Rehnisch, L.; Sperlich, D.; Ariza, D.; Bloch, I.; Díez, S.; Gregor, I.; Keller, J.; Lohwasser, K.; Poley, L.; Prahl, V.; Zakharchuk, N.; Hauser, M.; Jakobs, K.; Mahboubi, K.; Mori, R.; Parzefall, U.; Bernabéu, J.; Lacasta, C.; Marco-Hernandez, R.; Rodriguez Rodriguez, D.; Santoyo, D.; Solaz Contell, C.; Soldevila Serrano, U.; Affolder, T.; Greenall, A.; Gallop, B.; Phillips, P. W.; Cindro, V.

    2018-03-01

    In the high luminosity era of the Large Hadron Collider, the instantaneous luminosity is expected to reach unprecedented values, resulting in about 200 proton-proton interactions in a typical bunch crossing. To cope with the resultant increase in occupancy, bandwidth and radiation damage, the ATLAS Inner Detector will be replaced by an all-silicon system, the Inner Tracker (ITk). The ITk consists of a silicon pixel and a strip detector and exploits the concept of modularity. Prototyping and testing of various strip detector components has been carried out. This paper presents the developments and results obtained with reduced-size structures equivalent to those foreseen to be used in the forward region of the silicon strip detector. Referred to as petalets, these structures are built around a composite sandwich with embedded cooling pipes and electrical tapes for routing the signals and power. Detector modules built using electronic flex boards and silicon strip sensors are glued on both the front and back side surfaces of the carbon structure. Details are given on the assembly, testing and evaluation of several petalets. Measurement results of both mechanical and electrical quantities are shown. Moreover, an outlook is given for improved prototyping plans for large structures.

  8. Readout of non-irradiated and irradiated strip detectors with fast analogue electronics

    CERN Document Server

    Cindro, V; Mikuz, M; Zontar, D; Kaplon, J; Riedler, P; Roe, S; Weilhammer, Peter; Dabrowski, W

    2000-01-01

    Silicon microstrip detectors with 50 mu m readout pitch were connected to fast LHC-type analogue readout electronics (DMILL SCT32A) and their performance evaluated before and after irradiation. The p-type strips with a length of 4 cm were fabricated on high- resistivity n-bulk wafers by CSEM. Fast neutrons from the TRIGA research reactor in Ljubljana were used to irradiate detectors to two different fluences: 4.5*10/sup 13/ and 1.5*10/sup 14//cm/sup 2/ 1 MeV neutron equivalent non-ionizing energy loss. A /sup 90/Sr beta source setup was used for detector performance measurements. Most of the observed signal/noise degradation after irradiation could be attributed to the signal loss. Around 82Xharge collection efficiency was measured at higher fluence 100 V above full depletion voltage as determined with C-V measurements. Measurements were performed during annealing and reverse annealing of effective dopant concentration. (9 refs).

  9. Silicon Strip detectors for the ATLAS End-Cap Tracker at the HL-LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00232570

    Inside physics programme of the LHC different experiment upgrades are foreseen. After the phase-II upgrade of the ATLAS detector the luminosity will be increased up to 5-7.5x10E34 cm-2s-1. This will mean a considerable increase in the radiation levels, above 10E16 neq/cm2 in the inner regions. This thesis is focused on the development of silicon microstrip detectors enough radiation hard to cope with the particle fluence expected at the ATLAS detector during HL-LHC experiment. In particular on the electrical characterization of silicon sensors for the ATLAS End-Caps. Different mechanical and thermal tests are shown using a Petal core as well as the electrical characterization of the silicon sensors that will be used with the Petal structure. Charge collection efficiency studies are carried out on sensors with different irradiation fluences using the ALiBaVa system and two kinds of strips connection are also analized (DC and AC ganging) with a laser system. The Petalet project is presented and the electrical c...

  10. Beam loss studies on silicon strip detector modules for the CMS experiment

    CERN Document Server

    Fahrer, Manuel

    2006-01-01

    The large beam energy of the LHC demands for a save beam abort system. Nevertheless, failures cannot be excluded with last assurance and are predicted to occur once per year. As the CMS experiment is placed in the neighboured LHC octant, it is affected by such events. The effect of an unsynchronized beam abort on the silicon strip modules of the CMS tracking detector has been investigated in this thesis by performing one accelerator and two lab experiments. The dynamical behaviour of operational parameters of modules and components has been recorded during simulated beam loss events to be able to disentangle the reasons of possible damages. The first study with high intensive proton bunches at the CERN PS ensured the robustness of the module design against beam losses. A further lab experiment with pulsed IR LEDs clarified the physical and electrical processes during such events. The silicon strip sensors on a module are protected against beam losses by a part of the module design that originally has not been...

  11. Non-invasive characterization and quality assurance of silicon micro-strip detectors using pulsed infrared laser

    Science.gov (United States)

    Ghosh, P.

    2016-01-01

    The Compressed Baryonic Matter (CBM) experiment at FAIR is composed of 8 tracking stations consisting of roughly 1300 double sided silicon micro-strip detectors of 3 different dimensions. For the quality assurance of prototype micro-strip detectors a non-invasive detector charaterization is developed. The test system is using a pulsed infrared laser for charge injection and characterization, called Laser Test System (LTS). The system is aimed to develop a set of characterization procedures which are non-invasive (non-destructive) in nature and could be used for quality assurances of several silicon micro-strip detectors in an efficient, reliable and reproducible way. The procedures developed (as reported here) uses the LTS to scan sensors with a pulsed infra-red laser driven by step motor to determine the charge sharing in-between strips and to measure qualitative uniformity of the sensor response over the whole active area. The prototype detector modules which are tested with the LTS so far have 1024 strips with a pitch of 58 μm on each side. They are read-out using a self-triggering prototype read-out electronic ASIC called n-XYTER. The LTS is designed to measure sensor response in an automatized procedure at several thousand positions across the sensor with focused infra-red laser light (spot size ≈ 12 μm, wavelength = 1060 nm). The pulse with a duration of ≈ 10 ns and power ≈ 5 mW of the laser pulse is selected such, that the absorption of the laser light in the 300 μm thick silicon sensor produces ≈ 24000 electrons, which is similar to the charge created by minimum ionizing particles (MIP) in these sensors. The laser scans different prototype sensors and various non-invasive techniques to determine characteristics of the detector modules for the quality assurance is reported.

  12. Performance of a CMS Silicon Strip Detector Module with APV25 Readout

    CERN Document Server

    Friedl, Markus; Bauer, Thomas; Hrubec, Josef; Krammer, Manfred

    2002-01-01

    The Compact Muon Solenoid experiment (CMS) at the Large Hadron Collider (LHC) at CERN will include a Silicon Strip Tracker covering a sensitive area of 206m2 with about ten million readout channels. Its silicon detectors, made from 6" wafers, will be read out by APV25 front-end chips, fabricated in the 0.25um deep submicron process which is intrinsically radiation-tolerant. A first prototype module has been built consisting of two chained silicon sensors of 320um thickness and three APV25 chips (version S0). The performance of this module has been evaluated in a pion and proton beam at the Paul Scherrer Institute (Villigen/CH).

  13. Development of a 2D silicon strip detector system for mammographic imaging using particle physics technology

    CERN Document Server

    Royle, G J; Speller, R D; Hall, G; Iles, G; Raymond, M; Corrin, E; Stelt, P F; Manthos, N; Triantis, F A

    2002-01-01

    2D silicon strip sensors using particle physics readout technology have been evaluated as mammographic detectors. Two different versions of the APV series of front-end electronics were used that provided different noise levels. The sensors were evaluated using a typical mammography X-ray spectrum. The spatial resolution was evaluated using line pair test patterns and the modulation transfer function (MTF) was measured using the Edge Response Function. Low contrast performance was measured using the TOR(MAX) test object. Limiting spatial resolution of 52 mu m was obtained and an MTF value of 0.1 at 16 lp/mm. The low contrast performance was estimated from 250, 500 mu m and 6 mm diameter objects and was found to be 11.5%, 7% and better than 3.8%, respectively.

  14. SALT, a dedicated readout chip for high precision tracking silicon strip detectors at the LHCb Upgrade

    Science.gov (United States)

    Bugiel, Sz.; Dasgupta, R.; Firlej, M.; Fiutowski, T.; Idzik, M.; Kuczynska, M.; Moron, J.; Swientek, K.; Szumlak, T.

    2016-02-01

    The Upstream Tracker (UT) silicon strip detector, one of the central parts of the tracker system of the modernised LHCb experiment, will use a new 128-channel readout ASIC called SALT. It will extract and digitise analogue signals from the UT sensors, perform digital signal processing and transmit a serial output data. The SALT is being designed in CMOS 130 nm process and uses a novel architecture comprising of analog front-end and fast (40 MSps) ultra-low power (<0.5 mW) 6-bit ADC in each channel. The prototype ASICs of important functional blocks, like analogue front-end, 6-bit SAR ADC, PLL, and DLL, were designed, fabricated and tested. A prototype of an 8-channel version of the SALT chip, comprising all important functionalities was also designed and fabricated. The architecture and design of the SALT, together with the selected preliminary tests results, are presented.

  15. Prototyping of hybrids and modules for the forward silicon strip tracking detector for the ATLAS Phase-II upgrade

    Science.gov (United States)

    Kuehn, S.; Benítez, V.; Fernández-Tejero, J.; Fleta, C.; Lozano, M.; Ullán, M.; Lacker, H.; Rehnisch, L.; Sperlich, D.; Ariza, D.; Bloch, I.; Díez, S.; Gregor, I.; Keller, J.; Lohwasser, K.; Poley, L.; Prahl, V.; Zakharchuk, N.; Hauser, M.; Jakobs, K.; Mahboubi, K.; Mori, R.; Parzefall, U.; Bernabéu, J.; Lacasta, C.; Marco-Hernandez, R.; Santoyo, D.; Solaz Contell, C.; Soldevila Serrano, U.; Affolder, T.; Greenall, A.; Gallop, B.; Phillips, P. W.

    2017-05-01

    For the High-Luminosity upgrade of the Large Hadron Collider an increased instantaneous luminosity of up to 7.5 ṡ 1034 cm-2 s-1, leading to a total integrated luminosity of up to 3000 fb-1, is foreseen. The current silicon and transition radiation tracking detectors of the ATLAS experiment will be unable to cope with the increased track densities and radiation levels, and will need to be replaced. The new tracking detector will consist entirely of silicon pixel and strip detectors. In this paper, results on the development and tests of prototype components for the new silicon strip detector in the forward regions (end-caps) of the ATLAS detector are presented. Flex-printed readout boards with fast readout chips, referred to as hybrids, and silicon detector modules are investigated. The modules consist of a hybrid glued onto a silicon strip sensor. The channels on both are connected via wire-bonds for readout and powering. Measurements of important performance parameters and a comparison of two possible readout schemes are presented. In addition, the assembly procedure is described and recommendations for further prototyping are derived.

  16. Assembly and Electrical Tests of the First Full-size Forward Module for the ATLAS ITk Strip Detector

    CERN Document Server

    Garcia-Argos, Carlos; The ATLAS collaboration

    2018-01-01

    The ATLAS experiment will replace the existing Inner Detector by an all-silicon detector named the Inner Tracker (ITk) for the High Luminosity LHC upgrades. In the outer region of the Inner Tracker is the strip detector, which consists of a four layer barrel and six discs to each side of the barrel, with silicon-strip modules as basic units. Each module is composed of a sensor and one or more flex circuits that hold the read-out electronics. In the experiment, the modules are mounted on support structures with integrated power and cooling. The modules are designed with geometries that accommodate the central and forward regions, with rectangular sensors in the barrels and wedge shaped sensors in the end-caps. The strips lengths and pitch sizes vary according to the occupancy of the region. In this contribution, we present the construction and results of the electrical tests of the first full-size module of the innermost forward region, named \\textit{Ring 0} in the ATLAS ITk strip detector nomenclature. This m...

  17. Mechanical and Cooling Design Studies for an Integrated Stave Concept for Silicon Strip Detectors for the Super LHC

    CERN Document Server

    Cepeda, M; Gilchriese, M G D; Haber, C; Miller, W K; Miller, W O; Post, R

    2008-01-01

    Design studies for the mechanical and thermal performance of an integrated stave concept for large-area silicon-strip detector support and cooling are described. The fabrication and test of small-scale prototypes are also presented. Finite-element and other calculations have been completed to develop the design concept and to compare with the measurements on prototypes.

  18. Assembly and Electrical Tests of the First Full-size Forward Module for the ATLAS ITk Strip Detector

    CERN Document Server

    Garcia-Argos, Carlos; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment will replace the existing Inner Detector by an all-silicon detector named the Inner Tracker (ITk) for the High Luminosity LHC upgrades. In the outer region of the Inner Tracker is the strip detector, which consists of a four layer barrel and six discs to each side of the barrel, with silicon-strip modules as basic units. Each module is composed of a sensor and one or more flex circuits that hold the read-out electronics. In the experiment, the modules are mounted on support structures with integrated power and cooling. The modules are designed with geometries that accommodate the central and forward regions, with rectangular sensors in the barrels and wedge shaped sensors in the end-caps. The strips lengths and pitch sizes vary according to the occupancy of the region. In this contribution, we present the construction and the results of the electrical tests of the first full-size module of the innermost forward region, named Ring 0 in the ATLAS ITk strip detector nomenclature. This module...

  19. Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyo-Min; Ding, Huanjun; Molloi, Sabee, E-mail: symolloi@uci.edu [Department of Radiological Sciences, University of California, Irvine, California 92697 (United States); Barber, William C.; Iwanczyk, Jan S. [DxRay Inc., Northridge, California 91324 (United States)

    2014-09-15

    Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The

  20. Space-based detectors

    DEFF Research Database (Denmark)

    Sesana, A.; Weber, W. J.; Killow, C. J.

    2014-01-01

    ) is planned for 2015. This mission and its payload “LISA Technology Package” will demonstrate key technologies for LISA. In this context, reference masses in free fall for LISA, and gravitational physics in general, was described by William Weber, laser interferometry at the pico-metre level and the optical......The parallel session C5 on Space-Based Detectors gave a broad overview over the planned space missions related to gravitational wave detection. Overviews of the revolutionary science to be expected from LISA was given by Alberto Sesana and Sasha Buchman. The launch of LISA Pathfinder (LPF...... bench of LPF was presented by Christian Killow and the performance of the LPF optical metrology system by Paul McNamara. While LPF will not yet be sensitive to gravitational waves, it may nevertheless be used to explore fundamental physics questions, which was discussed by Michele Armano. Some parts...

  1. The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry

    International Nuclear Information System (INIS)

    Wong, J. H. D.; Knittel, T.; Downes, S.; Carolan, M.; Lerch, M. L. F.; Petasecca, M.; Perevertaylo, V. L.; Metcalfe, P.; Jackson, M.; Rosenfeld, A. B.

    2011-01-01

    Purpose: Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp dose fall off. One of the major problems with quality assurance (QA) of SRT/SRS is the availability of suitable detectors with the required spatial resolution. The authors present a novel detector that they refer to as the dose magnifying glass (DMG), which has a high spatial resolution (0.2 mm) and is capable of meeting the stringent requirements of QA and dosimetry in SRS/SRT therapy. Methods: The DMG is an array of 128 phosphor implanted n + strips on a p-type Si wafer. The sensitive area defined by a single n + strip is 20x2000 μm 2 . The Si wafer is 375 μm thick. It is mounted on a 0.12 mm thick Kapton substrate. The authors studied the dose per pulse (dpp) and angular response of the detector in a custom-made SRS phantom. The DMG was used to determine the centers of rotation and positioning errors for the linear accelerator's gantry, couch, and collimator rotations. They also used the DMG to measure the profiles and the total scatter factor (S cp ) of the SRS cones. Comparisons were made with the EBT2 film and standard S cp values. The DMG was also used for dosimetric verification of a typical SRS treatment with various noncoplanar fields and arc treatments when applied to the phantom. Results: The dose per pulse dependency of the DMG was found to be cp agrees very well with the standard data with an average difference of 1.2±1.1%. Comparison of the relative intensity profiles of the DMG and EBT2 measurements for a simulated SRS treatment shows a maximum difference of 2.5%. Conclusions: The DMG was investigated for dose per pulse and angular dependency. Its

  2. Electromagnetic noise studies in a silicon strip detector, used as part of a luminosity monitor at LEP

    International Nuclear Information System (INIS)

    Oedegaard, T.; Tafjord, H.; Buran, T.

    1994-12-01

    As part of the luminosity monitor SAT in the DELPHI experiment at CERN's Large Electron Positron collider, a tracking detector constructed from silicon strip detector elements was installed in front of an electromagnetic calorimeter. The luminosity was measured by counting the number of Bhabha events at the interaction point of the electron and the positron beams. The tracking detector reconstructs tracks from the interaction point and the calorimeter measures the corresponding particles' energies.The SAT Tracker consists of 504 silicon strip detectors. The strips are DC-coupled to CMOS VLSI-chips, baptized Balder. The chip performs amplification, zero-suppression, digitalisation, and multiplexing. The requirements of good space resolution and high efficiency put strong requirements on noise control. A short description of the geometry and the relevant circuit layout is given. The authors describe the efforts made to minimise the electromagnetic noise in the detector and present some numbers of the noise level using various techniques. 11 refs., 5 figs., 4 tabs

  3. Noise characterization of silicon strip detectors-comparison of sensors with and without integrated jfet source-follower.

    CERN Document Server

    Giacomini, Gabriele

    Noise is often the main factor limiting the performance of detector systems. In this work a detailed study of the noise contributions in different types of silicon microstrip sensors is carried on. We investigate three sensors with double-sided readout fabricated by different suppliers for the ALICE experiment at the CERN LHC, in addition to detectors including an integrated JFET Source-Follower as a first signal conditioning stage. The latter have been designed as an attempt at improving the performance when very long strips, obtained by gangling together several sensors, are required. After a description of the strip sensors and of their operation, the “static” characterization measurements performed on them (current and capacitance versus voltage and/or frequency) are illustrated and interpreted. Numerical device simulation has been employed as an aid in interpreting some of the measurement results. The commonly used models for expressing the noise of the detector-amplifier system in terms of its relev...

  4. Characterization of a double-sided silicon strip detector autoradiography system

    Energy Technology Data Exchange (ETDEWEB)

    Örbom, Anders, E-mail: anders.orbom@med.lu.se; Ahlstedt, Jonas; Östlund, Karl; Strand, Sven-Erik [Department of Medical Radiation Physics, Lund University, Lund SE-22185 (Sweden); Serén, Tom; Auterinen, Iiro; Kotiluoto, Petri [VTT Technical Research Centre of Finland, Espoo FI-02044 (Finland); Hauge, Håvard [Biomolex AS, Oslo NO-0319 (Norway); Olafsen, Tove; Wu, Anna M.; Dahlbom, Magnus [Department of Molecular and Medical Pharmacology, David Geffen School of Medicine at UCLA, Los Angeles, California 90095 (United States)

    2015-02-15

    Purpose: The most commonly used technology currently used for autoradiography is storage phosphor screens, which has many benefits such as a large field of view but lacks particle-counting detection of the time and energy of each detected radionuclide decay. A number of alternative designs, using either solid state or scintillator detectors, have been developed to address these issues. The aim of this study is to characterize the imaging performance of one such instrument, a double-sided silicon strip detector (DSSD) system for digital autoradiography. A novel aspect of this work is that the instrument, in contrast to previous prototype systems using the same detector type, provides the ability for user accessible imaging with higher throughput. Studies were performed to compare its spatial resolution to that of storage phosphor screens and test the implementation of multiradionuclide ex vivo imaging in a mouse preclinical animal study. Methods: Detector background counts were determined by measuring a nonradioactive sample slide for 52 h. Energy spectra and detection efficiency were measured for seven commonly used radionuclides under representative conditions for tissue imaging. System dead time was measured by imaging {sup 18}F samples of at least 5 kBq and studying the changes in count rate over time. A line source of {sup 58}Co was manufactured by irradiating a 10 μm nickel wire with fast neutrons in a research reactor. Samples of this wire were imaged in both the DSSD and storage phosphor screen systems and the full width at half maximum (FWHM) measured for the line profiles. Multiradionuclide imaging was employed in a two animal study to examine the intratumoral distribution of a {sup 125}I-labeled monoclonal antibody and a {sup 131}I-labeled engineered fragment (diabody) injected in the same mouse, both targeting carcinoembryonic antigen. Results: Detector background was 1.81 × 10{sup −6} counts per second per 50 × 50 μm pixel. Energy spectra and

  5. Spectral CT of the extremities with a silicon strip photon counting detector

    Science.gov (United States)

    Sisniega, A.; Zbijewski, W.; Stayman, J. W.; Xu, J.; Taguchi, K.; Siewerdsen, J. H.

    2015-03-01

    Purpose: Photon counting x-ray detectors (PCXDs) are an important emerging technology for spectral imaging and material differentiation with numerous potential applications in diagnostic imaging. We report development of a Si-strip PCXD system originally developed for mammography with potential application to spectral CT of musculoskeletal extremities, including challenges associated with sparse sampling, spectral calibration, and optimization for higher energy x-ray beams. Methods: A bench-top CT system was developed incorporating a Si-strip PCXD, fixed anode x-ray source, and rotational and translational motions to execute complex acquisition trajectories. Trajectories involving rotation and translation combined with iterative reconstruction were investigated, including single and multiple axial scans and longitudinal helical scans. The system was calibrated to provide accurate spectral separation in dual-energy three-material decomposition of soft-tissue, bone, and iodine. Image quality and decomposition accuracy were assessed in experiments using a phantom with pairs of bone and iodine inserts (3, 5, 15 and 20 mm) and an anthropomorphic wrist. Results: The designed trajectories improved the sampling distribution from 56% minimum sampling of voxels to 75%. Use of iterative reconstruction (viz., penalized likelihood with edge preserving regularization) in combination with such trajectories resulted in a very low level of artifacts in images of the wrist. For large bone or iodine inserts (>5 mm diameter), the error in the estimated material concentration was errors of 20-40% were observed and motivate improved methods for spectral calibration and optimization of the edge-preserving regularizer. Conclusion: Use of PCXDs for three-material decomposition in joint imaging proved feasible through a combination of rotation-translation acquisition trajectories and iterative reconstruction with optimized regularization.

  6. Evaluation of high grid strip densities based on the moiré artifact analysis for quality assurance: Simulation and experiment

    Science.gov (United States)

    Je, U. K.; Park, C. K.; Lim, H. W.; Cho, H. S.; Lee, D. Y.; Lee, H. W.; Kim, K. S.; Park, S. Y.; Kim, G. A.; Kang, S. Y.; Park, J. E.; Kim, W. S.; Jeon, D. H.; Woo, T. H.

    2017-09-01

    We have recently developed precise x-ray grids having strip densities in the range of 100 - 250 lines/inch by adopting the precision sawing process and carbon interspace material for the demands of specific x-ray imaging techniques. However, quality assurance in the grid manufacturing has not yet satisfactorily conducted because grid strips of a high strip density are often invisible through an x-ray nondestructive testing with a flat-panel detector of an ordinary pixel resolution (>100 μm). In this work, we propose a useful method to evaluate actual grid strip densities over the Nyquist sampling rate based on the moiré artifact analysis. We performed a systematic simulation and experiment with several sample grids and a detector having a 143- μm pixel resolution to verify the proposed quality assurance method. According to our results, the relative differences between the nominal and the evaluated grid strip densities were within 0.2% and 1.8% in the simulation and experiment, respectively, which demonstrates that the proposed method is viable with an ordinary detector having a moderate pixel resolution for quality assurance in grid manufacturing.

  7. Silicon strip tracking detector development and prototyping for the Phase-II upgrade of the ATLAS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, S., E-mail: susanne.kuehn@cern.ch

    2016-07-11

    In about ten years from now, the Phase-II upgrade of the LHC will be carried out. Due to increased luminosity, a severe radiation dose and high particle rates will occur for the experiments. In consequence, several detector components will have to be upgraded. In the ATLAS experiment, the current inner detector will be replaced by an all-silicon tracking detector with the goal of at least delivering the present detector performance also in the harsh Phase-II LHC conditions. This report presents the current planning and results from first prototype measurements of the upgrade silicon strip tracking detector. - Highlights: • Upgrade of current inner detector of the ATLAS experiment foreseen for High-Luminosity-LHC. • Silicon strip tracker for the upgrade has a modular design, single units are built and tested standalone before assembly in larger structures. • The prototyping is well advanced and approaching maturity. • Several integrated objects have been built, e.g. 70 barrel and 40 endcap prototype modules show low noise test results. • Many additional R & D tasks are ongoing and the collaboration is planning for preparing a technical design report before the end of 2016.

  8. Performance of a 128 channel analogue front-end chip for read-out of Si strip detector modules for LHC experiments

    CERN Document Server

    Chesi, Enrico Guido; Cindro, V; Dabrowski, W; Ferrère, D; Kramberger, G; Kaplon, J; Lacasta, C; Lozano-Bahilo, J; Mikuz, M; Morone, C; Roe, S; Szczygiel, R; Tadel, M; Weilhammer, Peter; Zsenei, A

    2000-01-01

    We present a 128-channel analogue front-end chip, SCT128A-HC, for readout of silicon strip detectors employed in the inner tracking detectors of the LHC experiment. The chip is produced in the radiation hard DMILL technology. The architecture of the chip and critical design issues are discussed. The performance of the chip has been evaluated in details in the test bench and is presented in the paper. The chip is used to read out prototype analogue modules compatible in size, functionality and performance with the ATLAS SCT base line modules. Several full size detector modules equipped with SCT128A-HC chips has been built and tested successfully in the lab with beta particles as well as in the test beam. The results concerning the signal-to-noise ratio, noise occupancy, efficiency and spatial resolution are presented. The radiation hardness issues are discussed. (5 refs).

  9. Lithium analysis using a double-sided silicon strip detector at LIBAF

    Science.gov (United States)

    De La Rosa, Nathaly; Kristiansson, Per; Nilsson, E. J. Charlotta; Ros, Linus; Elfman, Mikael; Pallon, Jan

    2017-08-01

    Quantification and mapping possibilities of lithium in geological material, by Nuclear Reaction Analysis (NRA), was evaluated at the Lund Ion Beam Analysis Facility (LIBAF). LiF and two Standard Reference Materials, (SRM 610 and SRM 612) were used in the investigation. The main part of the data was obtained at the beam energy 635 keV studying the high Q-value reaction 7Li(p, α)4He, but reaction yield and detection limits were also briefly investigated as a function of the energy. A double-sided silicon strip detector (DSSSD) was used to detect the α -particles emitted in the reaction in the backward direction. The combination of the high Q-value, a reasonably good cross-section and the possibility to use a high beam current have been demonstrated to allow for measurement of concentrations down below 50 ppm. Proton energies below 800 keV were demonstrated to be appropriate energies for extracting lithium in combination with boron analysis.

  10. Diagnostic analysis of silicon strips detector readout in the ATLAS Semi-Conductor Tracker module production

    CERN Document Server

    Ciocio, Alessandra

    2005-01-01

    The ATLAS Semi-Conductor Tracker (SCT) Collaboration is currently in the production phase of fabricating and testing silicon strips modules for the ATLAS detector at the Large Hadron Collider being built at the CERN laboratory in Geneva, Switzerland. A small but relevant percentage of ICs developed a new set of defects after being mounted on hybrids that were not detected in the wafer screening. To minimize IC replacement and outright module failure, analysis methods were developed to study IC problems during the production of SCT modules. These analyses included studying wafer and hybrid data correlations to finely tune the selection of ICs and tests to utilize the ability to adjust front-end parameters of the IC in order to reduce the rejection and replacement rate of fabricated components. This paper will discuss a few examples of the problems encountered during the production of SCT hybrids and modules in the area of ICs performance, and will demonstrate the value of the flexibility built into the ABCD3T ...

  11. Design and performance of the ABCD3TA ASIC for readout of silicon strip detectors in the ATLAS semiconductor tracker

    Czech Academy of Sciences Publication Activity Database

    Campabadal, F.; Fleta, C.; Key, M.; Böhm, Jan; Mikeštíková, Marcela; Šťastný, Jan

    2005-01-01

    Roč. 552, - (2005), s. 292-328 ISSN 0168-9002 R&D Projects: GA MŠk 1P04LA212 Institutional research plan: CEZ:AV0Z10100502 Keywords : front-end electronics * binary readout * silicon strip detectors * application specific integrated circuits * quality assurance Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.224, year: 2005

  12. Study of the physical processes involved in the operating mode of the micro-strips gas detector Micromegas

    International Nuclear Information System (INIS)

    Barouch, G.

    2001-04-01

    Micromegas is a micro-strip gaseous detector invented in 1996. It consists of two volumes of gas separated by a micro-mesh. The first volume of gas, 3 mm thick, is used to liberate ionization electrons from the incident charged particle. In the second volume, only 100 μm thick, an avalanche phenomenon amplifies the electrons produced in the first volume. Strips printed on an insulating substrate collect the electrons from the avalanche. The geometrical configuration of Micromegas showed many advantages. The short anode-cathode distance combined with a high granularity provide high rate capabilities due to a fast collection of ions produced during the avalanche development. Moreover, the possibility to localize the avalanche with strips printed about every hundreds of micrometers allows to measure the position of the incident particle with a good resolution. In this work, experimental tests of Micromegas are presented along with detailed Monte Carlo simulations used to understand and optimize the detector's performances. The prototypes were tested several times at the PS accelerator at CERN. The analysis of the date showed a stable and efficient behavior of Micromegas combined with an excellent space resolution. In fact, spatial resolutions of less than 15 μm were obtained. In parallel with the in-beam tests, several simulations have been developed in order to gain a better understanding of the detector's response. (author)

  13. NaI(Tl) scintillator detectors stripping procedure for air kerma measurements of diagnostic X-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, L.S.R. [Centro Tecnológico do Exército, CTEx (Brazilian Army Technological Center), Av. das Américas n° 28705, 23085-470 Rio de Janeiro (Brazil); Instituto de Radioprotecão e Dosimetria, CNEN/IRD (Institute for Radioprotection and Dosimetry, CNEN/IRD), Av. Salvador Allende s/no, P.O. Box 37750, 22783-127 Barra da Tijuca, Rio de Janeiro (Brazil); Conti, C.C., E-mail: ccconti@ird.gov.br [Instituto de Radioprotecão e Dosimetria, CNEN/IRD (Institute for Radioprotection and Dosimetry, CNEN/IRD), Av. Salvador Allende s/no, P.O. Box 37750, 22783-127 Barra da Tijuca, Rio de Janeiro (Brazil); Amorim, A.S.; Balthar, M.C.V. [Centro Tecnológico do Exército, CTEx (Brazilian Army Technological Center), Av. das Américas n° 28705, 23085-470 Rio de Janeiro (Brazil)

    2013-03-21

    Air kerma is an essential quantity for the calibration of national standards used in diagnostic radiology and the measurement of operating parameters used in radiation protection. Its measurement within the appropriate limits of accuracy, uncertainty and reproducibility is important for the characterization and control of the radiation field for the dosimetry of the patients submitted to diagnostic radiology and, also, for the assessment of the system which produces radiological images. Only the incident beam must be considered for the calculation of the air kerma. Therefore, for energy spectrum, counts apart the total energy deposition in the detector must be subtracted. It is necessary to establish a procedure to sort out the different contributions to the original spectrum and remove the counts representing scattered photons in the detector’s materials, partial energy deposition due to the interactions in the detector active volume and, also, the escape peaks contributions. The main goal of this work is to present spectrum stripping procedure, using the MCNP Monte Carlo computer code, for NaI(Tl) scintillation detectors to calculate the air kerma due to an X-ray beam usually used in medical radiology. The comparison between the spectrum before stripping procedure against the reference value showed a discrepancy of more than 63%, while the comparison with the same spectrum after the stripping procedure showed a discrepancy of less than 0.2%.

  14. T-CAD analysis of electric fields in n-in-p silicon strip detectors in dependence on the p-stop pattern and doping concentration

    CERN Document Server

    Printz, Martin

    2015-01-01

    However, n-in-p detectors necessarily need an isolation layer of the n+ strips due to an accumula- tion layer of electrons caused by positive charge in the SiO$_2$ at the sensor surface. An additional implantation of acceptors like boron between the n+ strips cuts the co...

  15. Calibration of RPC-based muon detector at BESIII

    International Nuclear Information System (INIS)

    Xie Yuguang; Bian Jianming; Cao Guofu; Cao Xuexiang; He Miao; Huang Bin; Liu Qiuguang; Ma Xiang; Sun Yongzhao; Wang Jike; Wang Liangliang; Wu Linghui; Yan Liang; Li Weidong; Zhang Jiawen; Deng Ziyan; He Kanglin; Ji Xiaobin; Li Fei; Li Haibo; Liu Chunxiu; Liu Huaimin; Liu Yingjie; Ma Qinmei; Mao Zepu; Mo Xiaohu; Ping Ronggang; Qiu Jinfa; Sun Shengsen; Wen Shuopin; Yuan Changzheng; Yuan Ye; Zhang Bingyun; Zhang Changchun; Zhang Jianyong; Zhang Yao; Zhu Kejun; Zhu Yongsheng; Liang Yutie; You Zheng yun; Mao Yajun; Chen Shenjian; Fu Chengdong; Gao Yuanning; Hua Chunfei; Qin Yahong; Huang Xingtao; Zhang Xueyao; Zou Jiaheng; Liu Suo; Pan Minghua; Pang Caiying; Zhu Zhili; Xu Min

    2010-01-01

    The calibration algorithm for RPC-based muon detector at BESIII has been developed. The calibration method, calibration error and algorithm performance are studied. The primary results of efficiency and noise at layer, module and strip levels have been calibrated with cosmic ray data. The calibration constants are available for simulation and reconstruction tuning. The results of Monte Carlo and data are also compared to check the validation and reliability of the algorithm. (authors)

  16. Application of a powder diffractometer equipped with a strip detector and Johansson monochromator to phase analysis and structure refinement

    Science.gov (United States)

    Paszkowicz, Wojciech

    2005-10-01

    During the past two decades, 1D and 2D semiconductor photon-counting detectors found applications, e.g., in detection of elementary particles and in medicine. More recent is their use for the X-ray diffraction and spectroscopy, where they become highly competitive with other detector types. Practical applications of such 1D detectors, built from up to about a hundred (at laboratory diffractometers) to several hundred (at a synchrotron beamline) of strips of size of the order 0.1×10 mm, to diffraction purposes started at the turn of the century. In the present study, selected properties of a laboratory X-ray powder diffractometer equipped with a linear photon-counting detector and a primary-beam Johansson monochromator are described. Aberrations characteristic to Bragg-Brentano instruments equipped with linear detectors are experimentally shown to be weak for 2.1° angular range covered by the detector used in this study. The counting statistics provided by this setting is shown to largely outperform that obtained with the settings equipped with point detectors. Consequently, diffraction peaks are detectable down to the level of 0.1% intensity, permitting for identification of minor impurity phases. Using illustrative examples, it is demonstrated that, with the described instrument, phase analysis of bulk polycrystals and thin polycrystalline layers is facilitated, and that structure refinement of collected data can be successfully performed.

  17. Characterisation of edgeless technologies for pixellated and strip silicon detectors with a micro-focused X-ray beam

    Science.gov (United States)

    Bates, R.; Blue, A.; Christophersen, M.; Eklund, L.; Ely, S.; Fadeyev, V.; Gimenez, E.; Kachkanov, V.; Kalliopuska, J.; Macchiolo, A.; Maneuski, D.; Phlips, B. F.; Sadrozinski, H. F.-W.; Stewart, G.; Tartoni, N.; Zain, R. M.

    2013-01-01

    Reduced edge or ``edgeless'' detector design offers seamless tileability of sensors for a wide range of applications from particle physics to synchrotron and free election laser (FEL) facilities and medical imaging. Combined with through-silicon-via (TSV) technology, this would allow reduced material trackers for particle physics and an increase in the active area for synchrotron and FEL pixel detector systems. In order to quantify the performance of different edgeless fabrication methods, 2 edgeless detectors were characterized at the Diamond Light Source using an 11 μm FWHM 15 keV micro-focused X-ray beam. The devices under test were: a 150 μm thick silicon active edge pixel sensor fabricated at VTT and bump-bonded to a Medipix2 ROIC; and a 300 μm thick silicon strip sensor fabricated at CIS with edge reduction performed by SCIPP and the NRL and wire bonded to an ALiBaVa readout system. Sub-pixel resolution of the 55 μm active edge pixels was achieved. Further scans showed no drop in charge collection recorded between the centre and edge pixels, with a maximum deviation of 5% in charge collection between scanned edge pixels. Scans across the cleaved and standard guard ring edges of the strip detector also show no reduction in charge collection. These results indicate techniques such as the scribe, cleave and passivate (SCP) and active edge processes offer real potential for reduced edge, tiled sensors for imaging detection applications.

  18. Testbeam Results from Pre and Post Irradiated Modules for the Upgrade of the ATLAS Strip Tracking Detector

    CERN Document Server

    Blue, Andrew; The ATLAS collaboration

    2016-01-01

    The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential of the LHC through a sizeable increase in the luminosity, reaching 1x1035cm-2s-1 after 10 years of operation. A consequence of this increased luminosity is the expected radiation damage at a integrated luminosity of 3000fb-1, requiring the tracking detectors to withstand hadron fluencies to over 1x1016 1 MeV neutron equivalent per cm2. With the addition of increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk), which will consist of both strip and pixelated silicon detectors. The silicon strip tracker exploits the concept of modularity. Fast readout electronics, deploying 130nm CMOS front-end electronics is glued on top of a silicon sensor. These so-called modules are glued on carbon structures and will span about 200m^2 of active area. A broad R&D program is ongoing to develop and prototype many detector components. The modules ...

  19. Performance of a single photon counting microstrip detector for strip pitches down to 10 μm

    Science.gov (United States)

    Bergamaschi, A.; Broennimann, Ch.; Dinapoli, R.; Eikenberry, E.; Gozzo, F.; Henrich, B.; Kobas, M.; Kraft, P.; Patterson, B.; Schmitt, B.

    2008-06-01

    The MYTHEN detector is a one-dimensional microstrip detector with single photon counting readout optimized for time resolved powder diffraction experiments at the Swiss Light Source (SLS). The system has been successfully tested for many different synchrotron radiation applications including phase contrast and tomographic imaging, small angle scattering, diffraction and time resolved pump and probe experiments for X-ray energies down to 5 keV and counting rate up to 3 MHz. The frontend electronics is designed in order to be coupled to 50 μm pitch microstrip sensors but some interest in enhancing the spatial resolution is arising for imaging and powder diffraction experiments. A test structure with strip pitches in the range 10-50 μm has been tested and the gain and noise on the readout electronics have been measured for the different strip pitches, observing no large difference down to 25 μm. Moreover, the effect of the charge sharing between neighboring strips on the spatial resolution has been quantified by measuring the Point Spread Function (PSF) of the system for the different pitches.

  20. Characterisation of strip silicon detectors for the ATLAS Phase-II Upgrade with a micro-focused X-ray beam

    Science.gov (United States)

    Poley, L.; Blue, A.; Bates, R.; Bloch, I.; Díez, S.; Fernandez-Tejero, J.; Fleta, C.; Gallop, B.; Greenall, A.; Gregor, I.-M.; Hara, K.; Ikegami, Y.; Lacasta, C.; Lohwasser, K.; Maneuski, D.; Nagorski, S.; Pape, I.; Phillips, P. W.; Sperlich, D.; Sawhney, K.; Soldevila, U.; Ullan, M.; Unno, Y.; Warren, M.

    2016-07-01

    The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential through a sizable increase in the luminosity up to 6·1034 cm-2s-1. A consequence of this increased luminosity is the expected radiation damage at 3000 fb-1 after ten years of operation, requiring the tracking detectors to withstand fluences to over 1·1016 1 MeV neq/cm2. In order to cope with the consequent increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk). Two proposed detectors for the ATLAS strip tracker region of the ITk were characterized at the Diamond Light Source with a 3 μm FWHM 15 keV micro focused X-ray beam. The devices under test were a 320 μm thick silicon stereo (Barrel) ATLAS12 strip mini sensor wire bonded to a 130 nm CMOS binary readout chip (ABC130) and a 320 μm thick full size radial (end-cap) strip sensor - utilizing bi-metal readout layers - wire bonded to 250 nm CMOS binary readout chips (ABCN-25). A resolution better than the inter strip pitch of the 74.5 μm strips was achieved for both detectors. The effect of the p-stop diffusion layers between strips was investigated in detail for the wire bond pad regions. Inter strip charge collection measurements indicate that the effective width of the strip on the silicon sensors is determined by p-stop regions between the strips rather than the strip pitch.

  1. Colloidal gold probe based rapid immunochromatographic strip assay for cortisol

    Energy Technology Data Exchange (ETDEWEB)

    Nara, Seema, E-mail: seemanara@mnnit.ac.in [Department of Applied Mechanics (Biotechnology), Motilal Nehru National Institute of Technology, Allahabad 211004 (India); Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India); Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Tripathi, Vinay [Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India); Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Singh, Harpal [Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Shrivastav, Tulsidas G. [Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India)

    2010-12-03

    A rapid and semi-quantitative immunochromatographic strip (ICS) test for cortisol analysis in serum was developed. The test strip was based on a competitive assay format. Colloidal gold nanoparticles were synthesized and coupled with cortisol-3-carboxymethyloxime-adipic acid dihydrazide-bovine serum albumin (F-3-CMO-ADH-BSA) antigen to directly compete with cortisol in human serum samples. F-3-CMO-ADH-BSA-gold label and uncoupled colloidal gold nanoparticles were appropriately characterized using UV-vis spectroscopy, transmission electron microscopy and atomic force microscopy. Anticortisol antibody raised against F-3-CMO-BSA immunogen in New Zealand white rabbits was coated on the NC membrane as test line. Anti-BSA antibody was used as control line. The lower detection limit of the ICS test was 30 ng mL{sup -1} with visual detection and was completed in 10 min. About 30 human serum samples were also analyzed by the developed strip test and their range of cortisol concentration was established. The developed ICS test is rapid, economic and user friendly.

  2. CCD-based vertex detectors

    CERN Document Server

    Damerell, C J S

    2005-01-01

    Over the past 20 years, CCD-based vertex detectors have been used to construct some of the most precise 'tracking microscopes' in particle physics. They were initially used by the ACCMOR collaboration for fixed target experiments in CERN, where they enabled the lifetimes of some of the shortest-lived charm particles to be measured precisely. The migration to collider experiments was accomplished in the SLD experiment, where the original 120 Mpixel detector was later upgraded to one with 307 Mpixels. This detector was used in a range of physics studies which exceeded the capability of the LEP detectors, including the most precise limit to date on the Bs mixing parameter. This success, and the high background hit densities that will inevitably be encountered at the future TeV-scale linear collider, have established the need for a silicon pixel-based vertex detector at this machine. The technical options have now been broadened to include a wide range of possible silicon imaging technologies as well as CCDs (mon...

  3. Design and performance of the ABCD chip for the binary readout of silicon strip detectors in the ATLAS semiconductor tracker

    CERN Document Server

    Dabrowski, W; Buttar, C M; Cindro, V; Clarks, A G; Dawson, I; Dorfan, D; Dubbs, T; Falconer, N; French, M; Greenall, A; Grillo, A A; Happer, R; Jarron, Pierre; Kaplon, J; Kudlaty, J; Kramberger, G; Lacasta, C; La Marra, D; Macina, Daniela; Mandic, I; Mikuz, M; Meddeler, G; Milgrome, O; Niggli, H; Phillips, P W; Roe, S; Smith, A; Spieler, H; Spencer, E; Szczygiel, R; Weilhammer, Peter; Wolter, M; Zsenei, A

    2000-01-01

    The ABCD design is a single chip implementation of the binary readout architecture for silicon strip detectors in the ATLAS semiconductor tracker. The prototype chip has been manufactured successfully in the DMILL process. In the paper we present the design of the chip and the measurement results. The basic analogue performance of the ABCD design has been evaluated using a prototype SCT module equipped with the ABCD chips. The digital performance has been evaluated using a general purpose IC tester. The measurements confirmed that all blocks of the ABCD design are fully functional and the chips meet all basic requirements of the SCT. (7 refs).

  4. Design, fabrication and characterization of multi-guard-ring furnished p+n-n+ silicon strip detectors for future HEP experiments

    Science.gov (United States)

    Lalwani, Kavita; Jain, Geetika; Dalal, Ranjeet; Ranjan, Kirti; Bhardwaj, Ashutosh

    2016-07-01

    Si detectors, in various configurations (strips and pixels), have been playing a key role in High Energy Physics (HEP) experiments due to their excellent vertexing and high precision tracking information. In future HEP experiments like upgrade of the Compact Muon Solenoid experiment (CMS) at the Large Hadron Collider (LHC), CERN and the proposed International Linear Collider (ILC), the Si tracking detectors will be operated in a very harsh radiation environment, which leads to both surface and bulk damage in Si detectors which in turn changes their electrical properties, i.e. change in the full depletion voltage, increase in the leakage current and decrease in the charge collection efficiency. In order to achieve the long term durability of Si-detectors in future HEP experiments, it is required to operate these detectors at very high reverse biases, beyond the full depletion voltage, thus requiring higher detector breakdown voltage. Delhi University (DU) is involved in the design, fabrication and characterization of multi-guard-ring furnished ac-coupled, single sided, p+n-n+ Si strip detectors for future HEP experiments. The design has been optimized using a two-dimensional numerical device simulation program (TCAD-Silvaco). The Si strip detectors are fabricated with eight-layers mask process using the planar fabrication technology by Bharat Electronic Lab (BEL), India. Further an electrical characterization set-up is established at DU to ensure the quality performance of fabricated Si strip detectors and test structures. In this work measurement results on non irradiated Si Strip detectors and test structures with multi-guard-rings using Current Voltage (IV) and Capacitance Voltage (CV) characterization set-ups are discussed. The effect of various design parameters, for example guard-ring spacing, number of guard-rings and metal overhang on breakdown voltage of test structures have been studied.

  5. Development of AC-coupled, poly-silicon biased, p-on-n silicon strip detectors in India for HEP experiments

    Science.gov (United States)

    Jain, Geetika; Dalal, Ranjeet; Bhardwaj, Ashutosh; Ranjan, Kirti; Dierlamm, Alexander; Hartmann, Frank; Eber, Robert; Demarteau, Marcel

    2018-02-01

    P-on-n silicon strip sensors having multiple guard-ring structures have been developed for High Energy Physics applications. The study constitutes the optimization of the sensor design, and fabrication of AC-coupled, poly-silicon biased sensors of strip width of 30 μm and strip pitch of 55 μm. The silicon wafers used for the fabrication are of 4 inch n-type, having an average resistivity of 2-5 k Ω cm, with a thickness of 300 μm. The electrical characterization of these detectors comprises of: (a) global measurements of total leakage current, and backplane capacitance; (b) strip and voltage scans of strip leakage current, poly-silicon resistance, interstrip capacitance, interstrip resistance, coupling capacitance, and dielectric current; and (c) charge collection measurements using ALiBaVa setup. The results of the same are reported here.

  6. ALICE silicon strip module

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    This small silicon detector strip will be inserted into the inner tracking system (ITS) on the ALICE detector at CERN. This detector relies on state-of-the-art particle tracking techniques. These double-sided silicon strip modules have been designed to be as lightweight and delicate as possible as the ITS will eventually contain five square metres of these devices.

  7. Analysis and comparison of the breakdown performance of semi- insulator and dielectric passivated Si strip detectors

    CERN Document Server

    Ranjan, Kirti; Chatterji, S; Srivastava-Ajay, K; Shivpuri, R K

    2002-01-01

    The harsh radiation environment in future high-energy physics (HEP) experiments like LHC provides a challenging task to the performance of Si microstrip detectors. Normal operating condition for silicon detectors in HEP experiments are in most cases not as favourable as for experiments in nuclear physics. In HEP experiments the detector may be exposed to moisture and other adverse atmospheric environment. It is therefore utmost important to protect the sensitive surfaces against such poisonous effects. These instabilities can be nearly eliminated and the performance of Si detectors can be improved by implementing suitably passivated metal-overhang structures. This paper presents the influence of the relative permittivity of the passivant on the breakdown performance of the Si detectors using computer simulations. The semi-insulator and the dielectric passivated metal-overhang structures are compared under optimal conditions. The influence of various parameters such as passivation layer thickness, junction dep...

  8. Developing silicon strip detectors with a large-scale commercial foundry

    Energy Technology Data Exchange (ETDEWEB)

    König, A., E-mail: axel.koenig@oeaw.ac.at [Institute of High Energy Physics, Austrian Academy of Sciences, Vienna (Austria); Bartl, U. [Infineon Technologies Austria AG, Villach (Austria); Bergauer, T.; Dragicevic, M. [Institute of High Energy Physics, Austrian Academy of Sciences, Vienna (Austria); Hacker, J. [Infineon Technologies Austria AG, Villach (Austria); Treberspurg, W. [Institute of High Energy Physics, Austrian Academy of Sciences, Vienna (Austria)

    2016-07-11

    Since 2009 the Institute of High Energy Physics (HEPHY) in Vienna is developing a production process for planar silicon strip sensors on 6-in. wafers together with the semiconductor manufacturer Infineon Technologies. Four runs with several batches of wafers, each comprising six different sensors, were manufactured and characterized. A brief summary of the recently completed 6-in. campaign is given. Milestones in sensor development as well as techniques to improve the sensor quality are discussed. Particular emphasis is placed on a failure causing areas of defective strips which accompanied the whole campaign. Beam tests at different irradiation facilities were conducted to validate the key capability of particle detection. Another major aspect is to prove the radiation hardness of sensors produced by Infineon. Therefore, neutron irradiation studies were performed.

  9. A silicon strip detector array for energy verification and quality assurance in heavy ion therapy.

    Science.gov (United States)

    Debrot, Emily; Newall, Matthew; Guatelli, Susanna; Petasecca, Marco; Matsufuji, Naruhiro; Rosenfeld, Anatoly B

    2018-02-01

    The measurement of depth dose profiles for range and energy verification of heavy ion beams is an important aspect of quality assurance procedures for heavy ion therapy facilities. The steep dose gradients in the Bragg peak region of these profiles require the use of detectors with high spatial resolution. The aim of this work is to characterize a one dimensional monolithic silicon detector array called the "serial Dose Magnifying Glass" (sDMG) as an independent ion beam energy and range verification system used for quality assurance conducted for ion beams used in heavy ion therapy. The sDMG detector consists of two linear arrays of 128 silicon sensitive volumes each with an effective size of 2mm × 50μm × 100μm fabricated on a p-type substrate at a pitch of 200 μm along a single axis of detection. The detector was characterized for beam energy and range verification by measuring the response of the detector when irradiated with a 290 MeV/u 12 C ion broad beam incident along the single axis of the detector embedded in a PMMA phantom. The energy of the 12 C ion beam incident on the detector and the residual energy of an ion beam incident on the phantom was determined from the measured Bragg peak position in the sDMG. Ad hoc Monte Carlo simulations of the experimental setup were also performed to give further insight into the detector response. The relative response profiles along the single axis measured with the sDMG detector were found to have good agreement between experiment and simulation with the position of the Bragg peak determined to fall within 0.2 mm or 1.1% of the range in the detector for the two cases. The energy of the beam incident on the detector was found to vary less than 1% between experiment and simulation. The beam energy incident on the phantom was determined to be (280.9 ± 0.8) MeV/u from the experimental and (280.9 ± 0.2) MeV/u from the simulated profiles. These values coincide with the expected energy of 281 MeV/u. The sDMG detector

  10. ATLAS strip detector: Operational Experience and Run1 → Run2 transition

    CERN Document Server

    NAGAI, K; The ATLAS collaboration

    2014-01-01

    The ATLAS SCT operational experience and the detector performance during the RUN1 period of LHC will be reported. Additionally the preparation outward to RUN2 during the long shut down 1 will be mentioned.

  11. Application of neural networks to digital pulse shape analysis for an array of silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Flores, J.L. [Dpto de Ingeniería Eléctrica y Térmica, Universidad de Huelva (Spain); Martel, I. [Dpto de Física Aplicada, Universidad de Huelva (Spain); CERN, ISOLDE, CH 1211 Geneva, 23 (Switzerland); Jiménez, R. [Dpto de Ingeniería Electrónica, Sist. Informáticos y Automática, Universidad de Huelva (Spain); Galán, J., E-mail: jgalan@diesia.uhu.es [Dpto de Ingeniería Electrónica, Sist. Informáticos y Automática, Universidad de Huelva (Spain); Salmerón, P. [Dpto de Ingeniería Eléctrica y Térmica, Universidad de Huelva (Spain)

    2016-09-11

    The new generation of nuclear physics detectors that used to study nuclear reactions is considering the use of digital pulse shape analysis techniques (DPSA) to obtain the (A,Z) values of the reaction products impinging in solid state detectors. This technique can be an important tool for selecting the relevant reaction channels at the HYDE (HYbrid DEtector ball array) silicon array foreseen for the Low Energy Branch of the FAIR facility (Darmstadt, Germany). In this work we study the feasibility of using artificial neural networks (ANNs) for particle identification with silicon detectors. Multilayer Perceptron networks were trained and tested with recent experimental data, showing excellent identification capabilities with signals of several isotopes ranging from {sup 12}C up to {sup 84}Kr, yielding higher discrimination rates than any other previously reported.

  12. Performance of a double metal n-on-n and a Czochralski silicon strip detector read out at 40 MHz

    CERN Document Server

    Palacios, J P; Buytaert, J; Collins, P; Eckstein, D; Härkönen, J; Luukka, Panja; Parkes, C; Tuovinen, E

    2004-01-01

    The R&D undertaken by the VELO group in order to produce a sensor that satisfies the tight radiation hardness, efficiency, resolution and low material requirements of LHCb has resulted in the choice of an n-on-n double metal layer solution. First, measurements of the performance of the latest prototype and its related front end electronics, designed to function at the LHC speed of 40 MHz, are presented here. In addition, research has been carried out into new materials which could retain good performance in high-radiation environments at and beyond the LHC, and could provide an alternative for a possible VELO upgrade. For the first time, a full size Czochralski silicon detector sample with 50 mum pitch strips has been irradiated with high energy protons and its performance has been measured in a test beam with 40 MHz electronics. The results of this test will be presented.

  13. Performance of a double metal n-on-n and a Czochralski silicon strip detector read out at 40 MHz

    CERN Document Server

    Palacios, J P; Buytaert, J; Collins, P; Eckstein, D; Harkonen, J; Tuovinen, E; Luukka, P

    2006-01-01

    The R&D undertaken by the VELO group in order to produce a sensor that satisfies the tight radiation hardness, efficiency, resolution and low material requirements of LHCb has resulted in the choice of an n-on-n double metal layer solution. First measurements of the performance of the latest prototype and its related front end electronics, designed to function at the LHC speed of 40 MHz, are presented here. In addition, research has been carried out into new materials which could retain good performance in high radiation environments at and beyond the LHC, and could provide an alternative for a possible VELO upgrade. For the first time a full size Czochralski silicon detector sample with 50$\\mu$m pitch strips has been irradiated with high energy protons and its performance has been measured in a test beam with 40 MHz electronics. The results of this test will be presented.

  14. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    CERN Document Server

    INSPIRE-00407830; Bloch, Ingo; Edwards, Sam; Friedrich, Conrad; Gregor, Ingrid M.; Jones, T; Lacker, Heiko; Pyatt, Simon; Rehnisch, Laura; Sperlich, Dennis; Wilson, John

    2016-05-24

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). This glue has several disadvantages, which motivated the search for an alternative. This paper presents a study concerning the use of six ultra-violet (UV) cure glues and a glue pad for use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, the thermal conduction and shear strength, thermal cycling, radiation hardness, corrosion resistance and shear strength tests. These investigatio...

  15. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS inner detector

    International Nuclear Information System (INIS)

    Poley, Luise; Bloch, Ingo; Edwards, Sam

    2016-04-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). This glue has several disadvantages, which motivated the search for an alternative. This paper presents a study concerning the use of six ultra-violet (UV) cure glues and a glue pad for use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, the thermal conduction and shear strength, thermal cycling, radiation hardness, corrosion resistance and shear strength tests. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives. Results from electrical tests of first prototype modules constructed using these glues are presented.

  16. Plasma-panel based detectors

    Science.gov (United States)

    Friedman, Peter

    2017-09-01

    The plasma panel sensor (PPS) is a novel micropattern gas detector inspired by plasma display panels (PDPs), the core component of plasma-TVs. A PDP comprises millions of discrete cells per square meter, each of which, when provided with a signal pulse, can initiate and sustain a plasma discharge. Configured as a detector, a pixel or cell is biased to discharge when a free-electron is generated in the gas. The PPS consists of an array of small plasma discharge pixels, and can be configured to have either an ``open-cell'' or ``closed-cell'' structure, operating with high gain in the Geiger region. We describe both configurations and their application to particle physics. The open-cell PPS lends itself to ultra-low-mass, ultrathin structures, whereas the closed-cell microhexcavity PPS is capable of higher performance. For the ultrathin-PPS, we are fabricating 3-inch devices based on two types of extremely thin, inorganic, transparent, substrate materials: one being 8-10 µm thick, and the other 25-27 µm thick. These gas-filled ultrathin devices are designed to operate in a beam-line vacuum environment, yet must be hermetically-sealed and gas-filled in an ambient environment at atmospheric pressure. We have successfully fabricated high resolution, submillimeter pixel electrodes on both types of ultrathin substrates. We will also report on the fabrication, staging and operation of the first microhexcavity detectors (µH-PPS). The first µH-PPS prototype devices have a 16 by 16 matrix of closed packed hexagon pixels, each having a 2 mm width. Initial tests of these detectors, conducted with Ne based gases at atmospheric pressure, indicate that each pixel responds independent of its neighboring cells, producing volt level pulse amplitudes in response to ionizing radiation. Results will include the hit rate response to a radioactive beta source, cosmic ray muons, the background from spontaneous discharge, pixel isolation and uniformity, and efficiency measurements. This

  17. A novel laser alignment system for tracking detectors using transparent silicon strip sensors

    International Nuclear Information System (INIS)

    Blum, W.; Kroha, H.; Widmann, P.

    1995-02-01

    Modern large-area precision tracking detectors require increasing accuracy of the geometrical alignment over large distances. A novel optical multi-point alignment system has been developed for the muon spectrometer of the ATLAS detector at the Large Hadron Collider. The system uses collimated laser beams as alignment references which are monitored by semi-transparent optical position sensors. The custom designed sensors provide very precise and uniform position information on the order of 1 μm over a wide measurement range. At suitable laser wavelengths, produced by laser diodes, transmission rates above 90% have been achieved which allow to align more than 30 sensors along one laser beam. With this capability and equipped with integrated readout electronics, the alignment system offers high flexibility for precision applications in a wide range of detector systems. (orig.)

  18. Prototyping of Silicon Strip Detectors for the Inner Tracker of the ALICE Experiment

    NARCIS (Netherlands)

    Sokolov, Oleksiy

    2006-01-01

    The ALICE experiment at CERN will study heavy ion collisions at a center-of-mass energy 5.5∼TeV per nucleon. Particle tracking around the interaction region at radii r<45 cm is done by the Inner Tracking System (ITS), consisting of six cylindrical layers of silicon detectors. The outer two layers of

  19. Study of pressure vessels for micro-strip-gas-counters as two-dimensional neutron position sensitive detectors

    International Nuclear Information System (INIS)

    Yamagishi, Hideshi; Kaneko, Junichi

    2001-01-01

    The development of two-dimensional position sensitive neutron detectors that have performances of a fast response and a very small space-resolution are required for various neutron scattering experiments using high-intensity pulse-neutron sources in a high-intensity proton accelerator facility. We put forward the development of a micro-strip gas counter (MSGC) filled with helium-3 gas as the two-dimensional position sensitive neutron detector. The MSGC requests a pressure vessel that withstands gas pressure of 5-10 atm. For obtainment of a small neutron-attenuation, the pressure vessel requires a neutron-window that is made thin wall and has small cross sections of absorption and scattering for low energy neutrons. We have studied and compared three kinds of neutron-windows for manufacturing the pressure vessel. After the study, we were able to design the pressure vessel with neutron-window thickness of 2 mm on conditions that are a window area of 100 x 100 mm, material of aluminum and inner pressure of 10 atm. (author)

  20. Design and development of a vertex reconstruction for the CMS (Compact Muon Solenoid) data. Study of gaseous and silicon micro-strips detectors (MSGC)

    International Nuclear Information System (INIS)

    Moreau, St.

    2002-12-01

    The work presented in this thesis has contributed to the development of the Compact Muon Solenoid detector (CMS) that will be installed at the future Large Hadron Collider (LHC) which will start running in summer 2007. This report is organised in three parts: the study of gaseous detectors and silicon micro-strips detectors, and a development of a software for the reconstruction and analysis of CMS data in the framework of ORCA. First, the micro-strips gaseous detectors (MSGC) study was on the ultimate critical irradiation test before their substitution in the CMS tracker. This test showed a really small number of lost anodes and a stable signal to noise ratio. This test proved that the described MSGC fulfill all the requirements to be integrated in the CMS tracker. The following contribution described a study of silicon micro-strips detectors and its electronics exposed to a 40 MHz bunched LHC like beam. These tests indicated a good behaviour of the data acquisition and control system. The signal to noise ratio, the bunch crossing identification and the cluster finding efficiency had also be analysed. The last study concern the design and the development of an ORCA algorithm dedicates to secondary vertex reconstruction. This iterative algorithm aims to be use for b tagging. This part analyse also primary vertex reconstruction in events without and with pile up. (author)

  1. The ATLAS inner detector semiconductor tracker (Si and GaAs strips) review of the 1995 beam tests at the CERN SPS H8 beamline

    CERN Document Server

    Moorhead, G F

    1995-01-01

    This talk will consist of a brief review of the ATLAS Inner Detector (ID) Semiconductor Tracker (SCT) strip detector (both silicon and gallium arsenide) beam tests conducted at the ATLAS test beam facility at the CERN SPS H8 beamline. It will include a brief overview of the H8 facilities, the experimental layout of the SCT/Strip apparatus, the data acquisition system, some of the online software tools and the high precision silicon hodoscope and timing modules used. A very brief indication of some of the main varieties of detector systems tested and the measurements performed will be given. Throughout some emphasis will be placed on the contributions and-interests of members of the Melbourne group. (author).

  2. Disposable copper-based electrochemical sensor for anodic stripping voltammetry.

    Science.gov (United States)

    Pei, Xing; Kang, Wenjing; Yue, Wei; Bange, Adam; Heineman, William R; Papautsky, Ian

    2014-05-20

    In this work, we report the first copper-based point-of-care sensor for electrochemical measurements demonstrated by zinc determination in blood serum. Heavy metals require careful monitoring, yet current methods are too complex for a point-of-care system. Electrochemistry offers a simple approach to metal detection on the microscale, but traditional carbon, gold (Au), or platinum (Pt) electrodes are difficult or expensive to microfabricate, preventing widespread use. Our sensor features a new low-cost electrode material, copper, which offers simple fabrication and compatibility with microfabrication and PCB processing, while maintaining competitive performance in electrochemical detection. Anodic stripping voltammetry of zinc using our new copper-based sensors exhibited a 140 nM (9.0 ppb) limit of detection (calculated) and sensitivity greater than 1 μA/μM in the acetate buffer. The sensor was also able to determine zinc in a bovine serum extract, and the results were verified with independent sensor measurements. These results demonstrate the advantageous qualities of this lab-on-a-chip electrochemical sensor for clinical applications, which include a small sample volume (μL scale), reduced cost, short response time, and high accuracy at low concentrations of analyte.

  3. MUST, a set of strip detectors for studying radioactive beams induced reactions; MUST, un ensemble de detecteurs a pistes pour l`etude des reactions induites par faisceaux radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Blumenfeld, Y.; Barbier, A.; Beaumel, D.; Charlet, D.; Clavelin, J.F.; Douet, R.; Engrand, M.; Lebon, S.; Lelong, P.; Lesage, A.; Leven, V.; Lhenry, I.; Marechal, F.; Petizon, L.; Pouthas, J.; Richard, A.; Rougier, D.; Soulet, C.; Suomijaervi, T.; Volkov, P.; Voltolini, G. [Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire; Auger, F.; Ottini, S.; Alamanos, N. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l`Instrumentation Associee; Sauvestre, J.E.; Bonnereau, B.; Champion, L.; Delbourgo-Salvador, P.; Ethvignot, T.; Szmigiel, M. [CEA Centre d`Etudes de Bruyeres-le-Chatel, 91 (France)

    1996-12-31

    This report states the specificity of light particles elastic scattering, and the need of detecting recoil protons to improve angular resolution. Then the development of a specific MUST strip detector is detailed: 60 strips detectors with Si O sub 2 dielectric, that yield 500 ps time resolution, and Si (Li) detectors following next. A versatile data acquisition system has been developed too, with CAMAC interface to suit to any experimental plant. (D.L.). 27 refs.

  4. Characterisation of micro-strip and pixel silicon detectors before and after hadron irradiation

    CERN Document Server

    Allport, P.P

    2012-01-01

    The use of segmented silicon detectors for tracking and vertexing in particle physics has grown substantially since their introduction in 1980. It is now anticipated that roughly 50,000 six inch wafers of high resistivity silicon will need to be processed into sensors to be deployed in the upgraded experiments in the future high luminosity LHC (HL-LHC) at CERN. These detectors will also face an extremely severe radiation environment, varying with distance from the interaction point. The volume of required sensors is large and their delivery is required during a relatively short time, demanding a high throughput from the chosen suppliers. The current situation internationally, in this highly specialist market, means that security of supply for large orders can therefore be an issue and bringing additional potential vendors into the field can only be an advantage. Semiconductor companies that could include planar sensors suitable for particle physics in their product lines will, however, need to prove their pro...

  5. Papers Based Electrochemical Biosensors: From Test Strips to Paper-Based Microfluidics

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Bingwen; Du, Dan; Hua, Xin; Yu, Xiao-Ying; Lin, Yuehe

    2014-05-08

    Papers based biosensors such as lateral flow test strips and paper-based microfluidic devices (or paperfluidics) are inexpensive, rapid, flexible, and easy-to-use analytical tools. An apparent trend in their detection is to interpret sensing results from qualitative assessment to quantitative determination. Electrochemical detection plays an important role in quantification. This review focuses on electrochemical (EC) detection enabled biosensors. The first part provides detailed examples in paper test strips. The second part gives an overview of paperfluidics engaging EC detections. The outlook and recommendation of future directions of EC enabled biosensors are discussed in the end.

  6. A Front-End Electronics Prototype Based on Gigabit Ethernet for the ATLAS Small-Strip Thin Gap Chamber

    Science.gov (United States)

    Hu, Kun; Lu, Houbing; Wang, Xu; Li, Feng; Wang, Xinxin; Geng, Tianru; Yang, Hang; Liu, Shengquan; Han, Liang; Jin, Ge

    2017-06-01

    A front-end electronics prototype for the ATLAS small-strip Thin Gap Chamber (sTGC) based on gigabit Ethernet has been developed. The prototype is designed to read out signals of pads, wires, and strips of the sTGC detector. The prototype includes two VMM2 chips developed to read out the signals of the sTGC, a Xilinx Kintex-7 field-programmable gate array (FPGA) used for the VMM2 configuration and the events storage, and a gigabit Ethernet transceiver PHY chip for interfacing with a computer. The VMM2 chip is designed for the readout of the Micromegas detector and sTGC detector, which is composed of 64 linear front-end channels. Each channel integrates a charge-sensitive amplifier, a shaper, several analog-to-digital converters, and other digital functions. For a bunch-crossing interval of 25 ns, events are continuously read out by the FPGA and forwarded to the computer. The interface between the computer and the prototype has been measured to reach an error-free rate of 900 Mb/s, therefore making a very effective use of the available bandwidth. Additionally, the computer can control several prototypes of this kind simultaneously via the Ethernet interface. At present, the prototype will be used for the sTGC performance test. The features of the prototype are described in detail.

  7. Optimization, evaluation and calibration of a cross-strip DOI detector

    Science.gov (United States)

    Schmidt, F. P.; Kolb, A.; Pichler, B. J.

    2018-02-01

    This study depicts the evaluation of a SiPM detector with depth of interaction (DOI) capability via a dual-sided readout that is suitable for high-resolution positron emission tomography and magnetic resonance (PET/MR) imaging. Two different 12  ×  12 pixelated LSO scintillator arrays with a crystal pitch of 1.60 mm are examined. One array is 20 mm-long with a crystal separation by the specular reflector Vikuiti enhanced specular reflector (ESR), and the other one is 18 mm-long and separated by the diffuse reflector Lumirror E60 (E60). An improvement in energy resolution from 22.6% to 15.5% for the scintillator array with the E60 reflector is achieved by taking a nonlinear light collection correction into account. The results are FWHM energy resolutions of 14.0% and 15.5%, average FWHM DOI resolutions of 2.96 mm and 1.83 mm, and FWHM coincidence resolving times of 1.09 ns and 1.48 ns for the scintillator array with the ESR and that with the E60 reflector, respectively. The measured DOI signal ratios need to be assigned to an interaction depth inside the scintillator crystal. A linear and a nonlinear method, using the intrinsic scintillator radiation from lutetium, are implemented for an easy to apply calibration and are compared to the conventional method, which exploits a setup with an externally collimated radiation beam. The deviation between the DOI functions of the linear or nonlinear method and the conventional method is determined. The resulting average of differences in DOI positions is 0.67 mm and 0.45 mm for the nonlinear calibration method for the scintillator array with the ESR and with the E60 reflector, respectively; Whereas the linear calibration method results in 0.51 mm and 0.32 mm for the scintillator array with the ESR and the E60 reflector, respectively; and is, due to its simplicity, also applicable in assembled detector systems.

  8. An X-ray imaging device based on a GEM detector with delay-line readout

    Science.gov (United States)

    Zhou, Yi; Li, Cheng; Sun, Yong-Jie; Shao, Ming

    2010-01-01

    An X-ray imaging device based on a triple-GEM (Gas Electron Multiplier) detector, a fast delay-line circuit with 700 MHz cut-off frequency and two dimensional readout strips with 150 μm width on the top and 250 μm width on the bottom, is designed and tested. The localization information is derived from the propagation time of the induced signals on the readout strips. This device has a good spatial resolution of 150 μm and works stably at an intensity of 105 Hz/mm2 with 8 keV X-rays.

  9. Metal detector technology data base

    Energy Technology Data Exchange (ETDEWEB)

    Porter, L.K.; Gallo, L.R.; Murray, D.W.

    1990-08-01

    The tests described in this report were conducted to obtain information on the effects target characteristics have on portal type metal detector response. A second purpose of the tests was to determine the effect of detector type and settings on the detection of the targets. Although in some cases comparison performance of different types and makes of metal detectors is found herein, that is not the primary purpose of the report. Further, because of the many variables that affect metal detector performance, the information presented can be used only in a general way. The results of these tests can show general trends in metal detection, but do little for making accurate predictions as to metal detector response to a target with a complex shape such as a handgun. The shape of an object and its specific metal content (both type and treatment) can have a significant influence on detection. Thus it should not be surprising that levels of detection for a small 100g stainless steel handgun are considerably different than for detection of the 100g stainless steel right circular cylinder that was used in these tests. 7 figs., 1 tab.

  10. Determining the dynamic range of MCPs based on pore size and strip current

    Science.gov (United States)

    Hunt, C.; Adrian, M. L.; Herrero, F.; James, P.; Jones, H. H.; Rodriguez, M.; Roman, P.; Shappirio, M.

    2010-12-01

    Micro-Channel Plates (MCPs) are used as detectors for almost all detectors measuring particles (both ions, electrons and neutrals) below 30 keV. Recent advances in the manufacturing technology of the MCPs have increased the number of options one has when selecting plates for an instrument. But it is not clear how many of these options affect the performance of the MCPs. In particular the dynamic range is not a clear cut calculation to make from the strip current. There is also some evidence that pore size and coating play a role. We measured the dynamic range and pulse height distribution of MCPs detector chevron stacks with a wide variety of strip currents from the low “normal” range in the EDR range. We also looked at the effects of varying the pore size from 25 microns to 10 microns, partial plating of the MCP surface and coating one surface on each MCP with gold rather than the standard zinc chromium. We will show how the dynamic range and pulse height distributions vary vs. strip current, pore size, and surface plating configurations.

  11. Development and evaluation of test stations for the quality assurance of the silicon micro-strip detector modules for the CMS experiment

    International Nuclear Information System (INIS)

    Poettgens, M.

    2007-01-01

    CMS (Compact Muon Solenoid) is one of four large-scale detectors which will be operated at the LHC (Large Hadron Collider) at the European Laboratory for Particle Physics (CERN). For the search for new physics the reconstruction of the collision products and their properties is essential. In the innermost part of the CMS detector the traces of ionizing particles are measured utilizing a silicon tracker. A large fraction of this detector is equipped with silicon micro-strip modules which provide a precise space resolution in 1-dimension. A module consists of a sensor for detection of particles, the corresponding read-out electronics (hybrid) and a mechanical support structure. Since the 15,148 modules, which will be installed in the silicon micro-strip detector, have a total sensitive surface area of about 198 m 2 , the inner tracker of CMS is the largest silicon tracking detector, which has ever been built. While the sensors and hybrids are produced in industry, the construction of the modules and the control of the quality is done by the members of the 21 participating institutes. Since the access to the silicon micro-strip tracker will be very limited after the installation in the CMS detector the installed modules must be of high quality. For this reason the modules are thoroughly tested and the test results are uploaded to a central database. By the development of a read-out system and the corresponding software the III. Physikalisches Institut made an important contribution for the electrical and functional quality control of hybrids and modules. The read-out system provides all features for the operation and test of hybrids and modules and stands out due to high reliability and simple handling. Because a very user-friedly and highly automated software it became the official test tool and was integrated in various test stands. The test stands, in which the read-out system is integrated in, are described and the tests which are implemented in the corresponding

  12. Development and Evaluation of Test Stations for the Quality Assurance of the Silicon Micro-Strip Detector Modules for the CMS Experiment

    CERN Document Server

    Pöttgens, Michael

    2007-01-01

    CMS (Compact Muon Solenoid) is one of four large-scale detectors which will be operated at the LHC (Large Hadron Collider) at the European Laboratory for Particle Physics (CERN). For the search for new physics the reconstruction of the collision products and their properties is essential. In the innermost part of the CMS detector the traces of ionizing particles are measured utilizing a silicon tracker. A large fraction of this detector is equipped with silicon micro-strip modules which provide a precise space resolution in 1-dimension. A module consists of a sensor for detection of particles, the corresponding read-out electronics (hybrid) and a mechanical support structure. Since the 15,148 modules, which will be installed in the silicon micro-strip detector, have a total sensitive surface area of about 198 m2, the inner tracker of CMS is the largest silicon tracking detector, which has ever been built. While the sensors and hybrids are produced in industry, the construction of the modules and the control o...

  13. Characterisation of strip silicon detectors for the ATLAS Phase-II Upgrade with a micro-focused X-ray beam

    CERN Document Server

    INSPIRE-00407830; Blue, Andrew; Bates, Richard; Bloch, Ingo; Diez, Sergio; Fernandez-Tejero, Javier; Fleta, Celeste; Gallop, Bruce; Greenall, Ashley; Gregor, Ingrid-Maria; Hara, Kazuhiko; Ikegami, Yoichi; Lacasta, Carlos; Lohwasser, Kristin; Maneuski, Dzmitry; Nagorski, Sebastian; Pape, Ian; Phillips, Peter W.; Sperlich, Dennis; Sawhney, Kawal; Soldevila, Urmila; Ullan, Miguel; Unno, Yoshinobu; Warren, Matt

    2016-07-29

    The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential through a sizable increase in the luminosity, totalling 1x10^35 cm^-2 s^-1 after 10 years of operation. A consequence of this increased luminosity is the expected radiation damage at 3000 fb^-1, requiring the tracking detectors to withstand hadron equivalences to over 1x10^16 1 MeV neutrons per cm^2. With the addition of increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk). Two proposed detectors for the ATLAS strip tracker region of the ITk were characterized at the Diamond Light Source with a 3 micron FWHM 15 keV micro focused X-ray beam. The devices under test were a 320 micron thick silicon stereo (Barrel) ATLAS12 strip mini sensor wire bonded to a 130 nm CMOS binary readout chip (ABC130) and a 320 micron thick full size radial (Endcap) strip sensor - utilizing bi-metal readout layers - wire bonded to 250 nm CMOS binary readout...

  14. Sequential Triangle Strip Generator based on Hopfield Networks

    Czech Academy of Sciences Publication Activity Database

    Šíma, Jiří; Lněnička, Radim

    2009-01-01

    Roč. 21, č. 2 (2009), s. 583-617 ISSN 0899-7667 R&D Projects: GA MŠk(CZ) 1M0545; GA AV ČR 1ET100300517; GA MŠk 1M0572 Institutional research plan: CEZ:AV0Z10300504; CEZ:AV0Z10750506 Keywords : sequential triangle strip * combinatorial optimization * Hopfield network * minimum energy * simulated annealing Subject RIV: IN - Informatics, Computer Science Impact factor: 2.175, year: 2009

  15. Evaluation of the performance of irradiated silicon strip sensors for the forward detector of the ATLAS Inner Tracker Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Mori, R., E-mail: riccardo.mori@physik.uni-freiburg.de [Physikalisches Institut, Universität Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Allport, P.P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J.P.; Wilson, J.A. [School of Physics and Astronomy, University of Birmingham, Birmingham B15 2TT (United Kingdom); Kierstead, J.; Kuczewski, P.; Lynn, D. [Brookhaven National Laboratory, Physics Department and Instrumentation Division, Upton, NY 11973-5000 (United States); Arratia-Munoz, M.I.; Hommels, L.B.A. [Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Ullan, M.; Fleta, C.; Fernandez-Tejero, J. [Centro Nacional de Microelectronica (IMB-CNM, CSIC), Campus UAB-Bellaterra, 08193 Barcelona (Spain); Bloch, I.; Gregor, I.M.; Lohwasser, K. [DESY, Notkestrasse 85, 22607 Hambrug (Germany); and others

    2016-09-21

    The upgrade to the High-Luminosity LHC foreseen in about ten years represents a great challenge for the ATLAS inner tracker and the silicon strip sensors in the forward region. Several strip sensor designs were developed by the ATLAS collaboration and fabricated by Hamamatsu in order to maintain enough performance in terms of charge collection efficiency and its uniformity throughout the active region. Of particular attention, in the case of a stereo-strip sensor, is the area near the sensor edge where shorter strips were ganged to the complete ones. In this work the electrical and charge collection test results on irradiated miniature sensors with forward geometry are presented. Results from charge collection efficiency measurements show that at the maximum expected fluence, the collected charge is roughly halved with respect to the one obtained prior to irradiation. Laser measurements show a good signal uniformity over the sensor. Ganged strips have a similar efficiency as standard strips.

  16. Efficient content-based low-altitude images correlated network and strips reconstruction

    Science.gov (United States)

    He, Haiqing; You, Qi; Chen, Xiaoyong

    2017-01-01

    The manual intervention method is widely used to reconstruct strips for further aerial triangulation in low-altitude photogrammetry. Clearly the method for fully automatic photogrammetric data processing is not an expected way. In this paper, we explore a content-based approach without manual intervention or external information for strips reconstruction. Feature descriptors in the local spatial patterns are extracted by SIFT to construct vocabulary tree, in which these features are encoded in terms of TF-IDF numerical statistical algorithm to generate new representation for each low-altitude image. Then images correlated network is reconstructed by similarity measure, image matching and geometric graph theory. Finally, strips are reconstructed automatically by tracing straight lines and growing adjacent images gradually. Experimental results show that the proposed approach is highly effective in automatically rearranging strips of lowaltitude images and can provide rough relative orientation for further aerial triangulation.

  17. MWCNTs based high sensitive lateral flow strip biosensor for rapid determination of aqueous mercury ions.

    Science.gov (United States)

    Yao, Li; Teng, Jun; Zhu, Mengya; Zheng, Lei; Zhong, Youhao; Liu, Guodong; Xue, Feng; Chen, Wei

    2016-11-15

    Here, we describe a disposable multi-walled carbon nanotubes (MWCNTs) labeled nucleic acid lateral flow strip biosensor for rapid and sensitive detection of aqueous mercury ions (Hg(2+)). Unlike the conventional colloidal gold nanoparticle based strip biosensors, the carboxylated MWCNTs were selected as the labeling substrate because of its high specific surface area for immobilization of recognition probes, improved stability and enhanced detection sensitivity of the strip biosensor. Combining the sandwich-type of T-Hg(2+)-T recognition mechanism with the optical properties of MWCNTs on lateral flow strip, optical black bands were observed on the lateral flow strips. Parameters (such as membrane category, the MWCNTs concentration, the amount of MWCNT-DNA probe, and the volume of the test probe) that govern the sensitivity and reproducibility of the sensor were optimized. The response of the optimized biosensor was highly linear over the range of 0.05-1ppb target Hg(2+), and the detection threshold was estimated at 0.05 ppb within a 15-min assay time. The sensitivity was 10-fold higher than the conventional colloidal gold based strip biosensor. More importantly, the stability of the sensor was also greatly improved with the usage of MWCNTs as the labeling. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  18. Development of a microstrip-based neutron detector

    Indian Academy of Sciences (India)

    detectors; neutron scattering and diffraction. PACS Nos ... X-rays and neutrons. The details of the fabrication and X-ray test results have been reported elsewhere [7,8]. We report here preliminary results obtained on performance of ... and has high resistance per unit length compared to that of the anode and cathode strips.

  19. Strip Steel Surface Defects Recognition Based on SOCP Optimized Multiple Kernel RVM

    Directory of Open Access Journals (Sweden)

    Hou Jingzhong

    2018-01-01

    Full Text Available Strip steel surface defect recognition is a pattern recognition problem with wide applications. Previous works on strip surface defect recognition mainly focus on feature selection and dimension reduction. There are also approaches on real-time systems that mainly exploit the autocorrection within some given picture. However, the instances cannot be used in practical applications because of a bad recognition rate and low efficiency. In this paper, we study the intelligent algorithm of strip steel surface defect recognition, where the goal is to improve the accuracy and save running time. This problem is very important in various applications, especially the process testing of steel manufacturing. We propose an approach called the second-order cone programming (SOCP optimized multiple kernel relevance vector machine (MKRVM, which can recognize strip surface defects much better than other methods. The method includes the model parameter estimation, training, and optimization of the model based on SOCP and the classification test. We compare our approach with existing methods on strip surface defect recognition. The results demonstrate that our proposed approach can improve the recognition accuracy and reduce the time costs of the strip surface defect.

  20. Norm based design of fault detectors

    DEFF Research Database (Denmark)

    Rank, Mike Lind; Niemann, Hans Henrik

    1999-01-01

    The design of fault detectors for fault detection and isolation (FDI) in dynamic systems is considered in this paper from a norm based point of view. An analysis of norm based threshold selection is given based on different formulations of FDI problems. Both the nominal FDI problem as well...

  1. Spectrum reconstruction method based on the detector response model calibrated by x-ray fluorescence.

    Science.gov (United States)

    Li, Ruizhe; Li, Liang; Chen, Zhiqiang

    2017-02-07

    Accurate estimation of distortion-free spectra is important but difficult in various applications, especially for spectral computed tomography. Two key problems must be solved to reconstruct the incident spectrum. One is the acquisition of the detector energy response. It can be calculated by Monte Carlo simulation, which requires detailed modeling of the detector system and a high computational power. It can also be acquired by establishing a parametric response model and be calibrated using monochromatic x-ray sources, such as synchrotron sources or radioactive isotopes. However, these monochromatic sources are difficult to obtain. Inspired by x-ray fluorescence (XRF) spectrum modeling, we propose a feasible method to obtain the detector energy response based on an optimized parametric model for CdZnTe or CdTe detectors. The other key problem is the reconstruction of the incident spectrum with the detector response. Directly obtaining an accurate solution from noisy data is difficult because the reconstruction problem is severely ill-posed. Different from the existing spectrum stripping method, a maximum likelihood-expectation maximization iterative algorithm is developed based on the Poisson noise model of the system. Simulation and experiment results show that our method is effective for spectrum reconstruction and markedly increases the accuracy of XRF spectra compared with the spectrum stripping method. The applicability of the proposed method is discussed, and promising results are presented.

  2. Design,construction and commissioning of a cylinder of double-sided silicon micro-strips detectors for the Star experiment at RHIC

    International Nuclear Information System (INIS)

    Guedon, M.

    2005-05-01

    This study has been performed in the frame of quark gluon plasma physics research in the STAR experiment at RHIC. It deals with the design, the construction and the commissioning of a barrel of silicon-strip detectors (SSD). Added to the Silicon Vertex Tracker (SVT) of the STAR detector, it extends the capabilities of track reconstruction for charged particles emitted in ultra-relativistic heavy-ion collisions. It also contributes to the general study of the quark-gluon plasma production undertaken at STAR. The SSD is a cylinder of 1 m long and of 23 cm radius, and it is composed of 320 compact identical modules. Each module includes one double-sided silicon micro-strip detector, 12 readout chips ALICE 128C, 12 TAB ribbons, 2 COSTAR control chips and 2 hybrids supporting all the components. The document explains why the SSD is an important and relevant element, and justifies the technological choices as well as their validation by in-beam characterization. All component functionalities, characteristics and test procedures are presented. The data and test results are stored in a database for tracing purpose. Component and module production is described. Two parallel studies have been performed, analysed and described. One on the temperature dependence of the module performances and the other one on the optimal adjustments of the analogue blocks inside the ALICE 128C chip. The SSD installation on the RHIC site as well as the commissioning are presented together with the first data takings. (author)

  3. A 2 × 2 mm2 superconducting strip-line detector for high-performance time-of-flight mass spectrometry

    International Nuclear Information System (INIS)

    Casaburi, A; Esposito, E; Ejrnaes, M; Cristiano, R; Suzuki, K; Ohkubo, M; Pagano, S

    2012-01-01

    We present the fabrication and characterization of the latest generation of superconducting strip-line detectors (SSLD) for application in time-of-flight mass spectrometer (TOF MS) of heavy molecules. The SSLD is realized in the parallel strip-line configuration to achieve a 2 × 2 mm 2 sensitive area. The parallel SSLD is mounted in a TOF MS and tested at 4.2 K under bombardment of lysozyme molecules. The detector exhibits output pulses with rise and fall times of 500 ps and 2.3 ns respectively. We also present measurements of the time evolution during the acquisition of the singly and doubly charged monomers and singly charged dimers peaks in the mass spectrum. We argue that the observed behavior proves that parallel SSLD can perform charge state discrimination. The achievement of a 2 × 2 mm 2 sensitive area with an output pulse rise time in the region of the sub-nanosecond and a fall time of a few nanoseconds is a milestone in the development of superconducting detectors for TOF MS applications because it addresses important issues such as high mass resolution and high-throughput analysis. (paper)

  4. ATLAS ITk Short Strip Prototype Module with Integrated DCDC Powering and Control Phase II Upgrade of the ATLAS Inner Tracker detector at the HL - LHC

    CERN Document Server

    Greenall, Ashley; The ATLAS collaboration

    2017-01-01

    The prototype Barrel module design, for the Phase II upgrade of the of the new Inner Tracker (ITk) detector at the LHC, has adopted an integrated low mass assembly featuring single-sided flexible circuits, with readout ASICs, glued to the silicon strip sensor. Further integration has been achieved by the attachment of module DCDC powering, HV sensor biasing switch and autonomous monitoring and control to the sensor. This low mass, integrated module approach benefits further in a reduced width stave structure to which the modules are attached. The results of preliminary electrical tests of such an integrated module will be presented.

  5. The ALICE forward multiplicity detector

    DEFF Research Database (Denmark)

    Holm Christensen, Christian; Gulbrandsen, Kristjan; Sogaard, Carsten

    2007-01-01

    The ALICE Forward Multiplicity Detector (FMD) is a silicon strip detector with 51,200 strips arranged in 5 rings, covering the range $-3.4......The ALICE Forward Multiplicity Detector (FMD) is a silicon strip detector with 51,200 strips arranged in 5 rings, covering the range $-3.4...

  6. D-FNN Based Modeling and BP Neural Network Decoupling Control of PVC Stripping Process

    Directory of Open Access Journals (Sweden)

    Shu-zhi Gao

    2014-01-01

    Full Text Available PVC stripping process is a kind of complicated industrial process with characteristics of highly nonlinear and time varying. Aiming at the problem of establishing the accurate mathematics model due to the multivariable coupling and big time delay, the dynamic fuzzy neural network (D-FNN is adopted to establish the PVC stripping process model based on the actual process operation datum. Then, the PVC stripping process is decoupled by the distributed neural network decoupling module to obtain two single-input-single-output (SISO subsystems (slurry flow to top tower temperature and steam flow to bottom tower temperature. Finally, the PID controller based on BP neural networks is used to control the decoupled PVC stripper system. Simulation results show the effectiveness of the proposed integrated intelligent control method.

  7. A 3D CZT high resolution detector for x- and gamma-ray astronomy

    DEFF Research Database (Denmark)

    Kuvvetli, Irfan; Budtz-Jørgensen, Carl; Zappettini, A.

    2014-01-01

    At DTU Space we have developed a high resolution three dimensional (3D) position sensitive CZT detector for high energy astronomy. The design of the 3D CZT detector is based on the CZT Drift Strip detector principle. The position determination perpendicular to the anode strips is performed using...

  8. Development and evaluation of test stations for the quality assurance of the silicon micro-strip detector modules for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Poettgens, M.

    2007-11-22

    CMS (Compact Muon Solenoid) is one of four large-scale detectors which will be operated at the LHC (Large Hadron Collider) at the European Laboratory for Particle Physics (CERN). For the search for new physics the reconstruction of the collision products and their properties is essential. In the innermost part of the CMS detector the traces of ionizing particles are measured utilizing a silicon tracker. A large fraction of this detector is equipped with silicon micro-strip modules which provide a precise space resolution in 1-dimension. A module consists of a sensor for detection of particles, the corresponding read-out electronics (hybrid) and a mechanical support structure. Since the 15,148 modules, which will be installed in the silicon micro-strip detector, have a total sensitive surface area of about 198 m{sup 2}, the inner tracker of CMS is the largest silicon tracking detector, which has ever been built. While the sensors and hybrids are produced in industry, the construction of the modules and the control of the quality is done by the members of the 21 participating institutes. Since the access to the silicon micro-strip tracker will be very limited after the installation in the CMS detector the installed modules must be of high quality. For this reason the modules are thoroughly tested and the test results are uploaded to a central database. By the development of a read-out system and the corresponding software the III. Physikalisches Institut made an important contribution for the electrical and functional quality control of hybrids and modules. The read-out system provides all features for the operation and test of hybrids and modules and stands out due to high reliability and simple handling. Because a very user-friedly and highly automated software it became the official test tool and was integrated in various test stands. The test stands, in which the read-out system is integrated in, are described and the tests which are implemented in the

  9. Evaluation of water based intelligent fluids for resist stripping in single wafer cleaning tools

    Science.gov (United States)

    Rudolph, Matthias; Esche, Silvio; Hohle, Christoph; Schumann, Dirk; Steinke, Philipp; Thrun, Xaver; von Sonntag, Justus

    2016-03-01

    The application of phasefluid based intelligent fluids® in the field of photoresist stripping was studied. Due to their highly dynamic inner structure, phasefluids penetrate into the polymer network of photoresists and small gaps between resist layer and substrate and lift off the material from the surface. These non-aggressive stripping fluids were investigated regarding their efficiency in various resist stripping applications including initial results on copper metallization. Furthermore intelligent fluids® have been evaluated on an industry standard high volume single wafer cleaner. A baseline process on 300 mm wafers has been developed and characterized in terms of metallic and ionic impurities and defect level. Finally a general proof of concept for removal of positive tone resist from 300 mm silicon wafers is demonstrated.

  10. Real time tracker based upon local hit correlation circuit for silicon strip sensors

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, Niklaus, E-mail: niklaus.lehmann@cern.ch [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Pirrami, Lorenzo [University of Applied Sciences Western Switzerland, Boulevard de Pérolles 80 – CP 32, CH-1705 Fribourg (Switzerland); Blue, Andrew [SUPA School of Physics and Astronomy, University of Glasgow, G12 8QQ (United Kingdom); Diez, Sergio [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Deutsches Elektronen-Synchrotron, Notkestraße 85, 22607 Hamburg (Germany); Dressnandt, Nandor [University of Pennsylvania, Philadelphia, PA 19104 (United States); Duner, Silvan [University of Applied Sciences Western Switzerland, Boulevard de Pérolles 80 – CP 32, CH-1705 Fribourg (Switzerland); Garcia-Sciveres, Maurice; Haber, Carl [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Halgeri, Amogh; Keener, Paul [University of Pennsylvania, Philadelphia, PA 19104 (United States); Keller, John [Deutsches Elektronen-Synchrotron, Notkestraße 85, 22607 Hamburg (Germany); Newcomer, Mitchell [University of Pennsylvania, Philadelphia, PA 19104 (United States); Pasner, Jacob [University of California Santa Cruz, 1156 High Street, Santa Cruz, CA 95064 (United States); Peschke, Richard [Deutsches Elektronen-Synchrotron, Notkestraße 85, 22607 Hamburg (Germany); Risbud, Amar [University of California Berkeley, Berkeley, CA 94720 (United States); Ropraz, Eric; Stalder, Jonas [University of Applied Sciences Western Switzerland, Boulevard de Pérolles 80 – CP 32, CH-1705 Fribourg (Switzerland); Wang, Haichen [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States)

    2016-01-11

    For the planned high luminosity upgrade of the Large Hadron Collider (LHC), a significant performance improvement of the detectors is required, including new tracker and trigger systems that makes use of charged track information early on. In this note we explore the principle of real time track reconstruction integrated in the readout electronics. A prototype was built using the silicon strip sensor for the ATLAS phase-II upgrade. The real time tracker is not the baseline for ATLAS but is nevertheless of interest, as the upgraded trigger design has not yet been finalized. For this, a new readout scheme in parallel with conventional readout, called the Fast Cluster Finder (FCF), was included in the latest prototype of the ATLAS strip detector readout chip (ABC130). The FCF is capable of finding hits within 6 ns and transmitting the found hit information synchronously every 25 ns. Using the FCF together with external correlation logic makes it possible to look for pairs of hits consistent with tracks from the interaction point above a transverse momentum threshold. A correlator logic finds correlations between two closely spaced parallel sensors, a “doublet”, and can generate information used as input to a lowest level trigger decision. Such a correlator logic was developed as part of a demonstrator and was successfully tested in an electron beam. The results of this test beam experiment proved the concept of the real time track vector processor with FCF.

  11. THE ATLAS INNER DETECTOR TRACK BASED ALIGNMENT

    CERN Document Server

    Marti i Garcia, Salvador; The ATLAS collaboration

    2018-01-01

    The alignment of the ATLAS Inner Detector is performed with a track-based alignment algorithm. Its goal is to provide an accurate description of the detector geometry such that track parameters are accurately determined and free from biases. Its software implementation is modular and configurable, with a clear separation of the alignment algorithm from the detector system specifics and the database handling. The alignment must cope with the rapid movements of the detector as well as with the slow drift of the different mechanical units. Prompt alignment constants are derived for every run at the calibration stage. These sets of constants are then dynamically split from the beginning of the run in many chunks, allowing to describe the tracker geometry as it evolves with time. The alignment of the Inner Detector is validated and improved by studying resonance decays (Z and J/psi to mu+mu-), as well as using information from the calorimeter system with the E/p method with electrons. A detailed study of these res...

  12. Design and Construction of Precision Tooling for the Construction of Resistive Strip Micromegas Detectors for the ATLAS Small Wheel Upgrade Project

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00389964; The ATLAS collaboration

    2015-01-01

    Mechanical precision is a key-aspect of the $2~m^2$ high-rate capable Micromegas detectors for the upgrade of the Small Wheels of the ATLAS muon spectrometer. 32 SM2 quadruplets will be built by four German sites with cathodes and strip-anodes made of stable honeycomb sandwiches.\\\\ To achieve the required single plane resolution below $100\\mu m$ the deviation from planarity of a single detector plane must not exceed $80\\mu m$ in direction perpendicular to the precision coordinate. The global position of the readout strips has to be within $30\\mu m$ for a single readout-plane of three PCBs, as well as between all four planes of a quadruplet.\\\\ Precision tooling is used for the correct positioning of readout PCBs and readout sandwich planes. For quality control of the planarity of the sandwich planes a laser distance sensor combined with a coordinate measurement system has been developed. Deviation from planarity below 10 $\\mu$m can be easily resolved.\\\\ We will present key features of the challenging construct...

  13. The MAPS based PXL vertex detector for the STAR experiment

    International Nuclear Information System (INIS)

    Contin, G.; Anderssen, E.; Greiner, L.; Silber, J.; Stezelberger, T.; Vu, C.; Wieman, H.; Woodmansee, S.; Schambach, J.; Sun, X.; Szelezniak, M.

    2015-01-01

    The Heavy Flavor Tracker (HFT) was installed in the STAR experiment for the 2014 heavy ion run of RHIC. Designed to improve the vertex resolution and extend the measurement capabilities in the heavy flavor domain, the HFT is composed of three different silicon detectors based on CMOS monolithic active pixels (MAPS), pads and strips respectively, arranged in four concentric cylinders close to the STAR interaction point. The two innermost HFT layers are placed at a radius of 2.7 and 8 cm from the beam line, respectively, and accommodate 400 ultra-thin (50 μ m) high resolution MAPS sensors arranged in 10-sensor ladders to cover a total silicon area of 0.16 m 2 . Each sensor includes a pixel array of 928 rows and 960 columns with a 20.7 μ m pixel pitch, providing a sensitive area of ∼ 3.8 cm 2 . The architecture is based on a column parallel readout with amplification and correlated double sampling inside each pixel. Each column is terminated with a high precision discriminator, is read out in a rolling shutter mode and the output is processed through an integrated zero suppression logic. The results are stored in two SRAM with ping-pong arrangement for a continuous readout. The sensor features 185.6 μ s readout time and 170 mW/cm 2 power dissipation. The detector is air-cooled, allowing a global material budget as low as 0.39% on the inner layer. A novel mechanical approach to detector insertion enables effective installation and integration of the pixel layers within an 8 hour shift during the on-going STAR run.In addition to a detailed description of the detector characteristics, the experience of the first months of data taking will be presented in this paper, with a particular focus on sensor threshold calibration, latch-up protection procedures and general system operations aimed at stabilizing the running conditions. Issues faced during the 2014 run will be discussed together with the implemented solutions. A preliminary analysis of the detector

  14. Search for heavy lepton resonances decaying to a Z boson and a lepton in proton-proton collisions at √(s)=8 TeV with the ATLAS detector and investigations of radiation tolerant silicon-strip detectors for the high-luminosity LHC upgrade of the ATLAS inner detector

    Energy Technology Data Exchange (ETDEWEB)

    Wiik-Fuchs, Liv

    2017-03-09

    The success of particle physics experiments, like those at the Large Hardon Collider (LHC) at CERN, relies on a worldwide interdisciplinary collaboration in a variety of different fields. This thesis contributes to two vital aspects in this area of research:in the first part of a search for heavy trilepton resonances decaying to a Z boson and an electron or muon is presented, while the second part focusses on research and development of radiation tolerant silicon tracking detectors designed for the upgrade of the ATLAS detector for the future luminosity upgrade of the LHC. The search for trilepton resonances is based on pp collision data taken at a centre-of-mass energy of 8 TeV by the ATLAS experiment at the LHC corresponding to an integrated luminosity of 20.3 fb{sup -1}. To reconstruct the narrow resonance, events with at least three leptons (electrons or muons) with a high-transverse momentum are selected. Two of these leptons are required to be consistent with originating from a Z boson decay. Since no significant excess above Standard Model background predictions is observed, 95% confidence level upper limits on the production cross section of trilepton resonances beyond the Standard Model are derived. The results of this analysis are interpreted in the context of vector-like lepton and type-III seesaw models. For the vector-like lepton model, most heavy lepton mass values in the range 113-176 GeV are excluded. For the type-III seesaw model, most mass values in the range 100-474 GeV are excluded. The second part of this thesis focusses on the development of radiation-tolerant silicon strip detectors for the luminosity upgrade of the ATLAS detector envisaged to commence in the year 2016. This thesis includes the results of several studies which contribute to multiple key aspects required for a successful upgrade of the silicon strip detector of the ATLAS Inner Tracker. Among these are the results of a beam test providing the first comparative results between

  15. Magnetic Fe3O4@TiO2 Nanoparticles-based Test Strip Immunosensing Device for Rapid Detection of Phosphorylated Butyrylcholinesterase

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Xiaoxiao; Zhang, Weiying; Lin, Yuehe; Du, Dan

    2013-12-15

    An integrated magnetic nanoparticles-based test-strip immunosensing device was developed for rapid and sensitive quantification of phosphorylated butyrylcholinesterase (BChE), the biomarker of exposure to organophosphous pesticides (OP), in human plasma. In order to overcome the difficulty in scarce availability of OP-specific antibody, here magnetic Fe3O4@TiO2 nanoparticles were used and adsorbed on the test strip through a small magnet inserted in the device to capture target OP-BChE through selective binding between TiO2 and OP moiety. Further recognition was completed by horseradish peroxidase (HRP) and anti-BChE antibody (Ab) co-immobilized gold nanoparticles (GNPs). Their strong affinities among Fe3O4@TiO2, OP-BChE and HRP/Ab-GNPs were characterized by quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and square wave voltammetry (SWV) measurements. After cutting off from test strip, the resulted immunocomplex (HRP/Ab-GNPs/OP-BChE/Fe3O4@TiO2) was measured by SWV using a screen printed electrode under the test zone. Greatly enhanced sensitivity was achieved by introduction of GNPs to link enzyme and antibody at high ratio, which amplifies electrocatalytic signal significantly. Moreover, the use of test strip for fast immunoreactions reduces analytical time remarkably. Coupling with a portable electrochemical detector, the integrated device with advanced nanotechnology displays great promise for sensitive, rapid and in-filed on-site evaluation of OP poisoning.

  16. Norm based Threshold Selection for Fault Detectors

    DEFF Research Database (Denmark)

    Rank, Mike Lind; Niemann, Henrik

    1998-01-01

    The design of fault detectors for fault detection and isolation (FDI) in dynamic systems is considered from a norm based point of view. An analysis of norm based threshold selection is given based on different formulations of FDI problems. Both the nominal FDI problem as well as the uncertain FDI...... problem are considered. Based on this analysis, a performance index based on norms of the involved transfer functions is given. The performance index allows us also to optimize the structure of the fault detection filter directly...

  17. Lateral flow strip for visual detection of K-ras mutations based on allele-specific PCR.

    Science.gov (United States)

    Wang, Cong; Chen, Xiaomin; Wu, Yuying; Li, Hao; Wang, Yu; Pan, Xiaofu; Tang, Tingting; Liu, Ziying; Li, Xiaokun

    2016-10-01

    To develop a convenient and sensitive point-of-care test for detecting gene mutations based on allele-specific PCR. To develop a lateral flow strip for visual detection of K-ras mutations based on a modified PCR, a specific DNA tag was covalently linked to the 5'-end of each primer by a nine-carbon linker to produce a sticky end. One of the sticky ends of the PCR products bound to gold nano-particles, while the other sticky end was captured onto a nitrocellulose membrane of lateral flow strips. The lateral flow strip showed a great sensitivity, which detected mutations in as low as 10 tumor cells. The positive rate and accuracy of the lateral flow strip for blood samples were over 92 and 96 %, respectively. The lateral flow strip provides an easy method for sensitive detection of gene mutations based on allele specific-PCR.

  18. Magnetoelastic Effect-Based Transmissive Stress Detection for Steel Strips: Theory and Experiment

    Directory of Open Access Journals (Sweden)

    Qingdong Zhang

    2016-08-01

    Full Text Available For the deficiencies of traditional stress detection methods for steel strips in industrial production, this paper proposes a non-contact stress detection scheme based on the magnetoelastic effect. The theoretical model of the transmission-type stress detection is established, in which the output voltage and the tested stress obey a linear relation. Then, a stress detection device is built for the experiment, and Q235 steel under uniaxial tension is tested as an example. The result shows that the output voltage rises linearly with the increase of the tensile stress, consistent with the theoretical prediction. To ensure the accuracy of the stress detection method in actual application, the temperature compensation, magnetic shielding and some other key technologies are investigated to reduce the interference of the external factors, such as environment temperature and surrounding magnetic field. The present research develops the theoretical and experimental foundations for the magnetic stress detection system, which can be used for online non-contact monitoring of strip flatness-related stress (tension distribution or longitudinal residual stress in the steel strip rolling process, the quality evaluation of strip flatness after rolling, the life and safety assessment of metal construction and other industrial production links.

  19. Airplane Ice Detector Based on a Microwave Transmission Line

    Science.gov (United States)

    Ngo, Phong; Arndt, G. Dickey; Carl, James R.

    2004-01-01

    An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a

  20. Characterization of a silicon strip detector for photon-counting spectral CT using monoenergetic photons from 40 keV to 120 keV

    Science.gov (United States)

    Liu, Xuejin; Bornefalk, Hans; Chen, Han; Danielsson, Mats; Karlsson, Staffan; Persson, Mats; Xu, Cheng; Huber, Ben

    2014-03-01

    Background: We are developing a segmented silicon strip detector that operates in photon-counting mode and allows pulse-height discrimination with 8 adjustable energy bins. In this work, we determine the energy resolution of the detector using monoenergetic x-ray radiation from 40 keV to 120 keV. We further investigate the effects of pulse pileup and charge sharing between detector channels that may lead to a decreased energy resolution. Methods: For each incident monochromatic x-ray energy, we obtain count spectra at different photon fluxes. These spectra corresponds to the pulse-height response of the detector and allow the determination of energy resolution and charge-sharing probability. The energy resolution, however, is influenced by signal pileup and charge sharing. Both effects are quantified using Monte Carlo simulations of the detector that aim to reproduce the conditions during the measurements. Results: The absolute energy resolution is found to increase from 1.7 to 2.1 keV for increasing energies 40 keV to 120 keV at the lowest measured photon flux. The effect of charge sharing is found to increase the absolute energy resolution by a factor of 1.025 at maximum. This increase is considered as negligibly small. The pileup of pulses leads to a deterioration rate of the energy resolution of 4 · 10-3 keV Mcps-1 mm2, corresponding to an increase of 0.04keV per 10 Mcps increase of the detected count rate.

  1. A Silicon-Strip Detector for Photon-Counting Spectral CT: Energy Resolution From 40 keV to 120 keV

    Science.gov (United States)

    Liu, Xuejin; Bornefalk, Hans; Chen, Han; Danielsson, Mats; Karlsson, Staffan; Persson, Mats; Xu, Cheng; Huber, Ben

    2014-06-01

    We are developing a segmented silicon-strip detector for spectral computed tomography. The detector operates in photon-counting mode and allows pulse-height discrimination with 8 adjustable energy bins. In this work, we determine the energy resolution of a detector module using monoenergetic x-rays from 40 keV to 120 keV, provided at the European Synchrotron Radiation Facility, Grenoble. For each incident x-ray energy, pulse height spectra at different input photon fluxes are obtained. We investigate changes of the energy resolution due to charge sharing between pixels and pulse pileup. The different incident energies are used to channel-wise calibrate the pulse-height response in terms of signal gain and offset and to probe the homogeneity of the detector module. The detector shows a linear pulse-height response in the energy range from 40 keV to 120 keV. The gain variation among the channels is below 4%, whereas the variation of the offsets is on the order of 1 keV. We find an absolute energy resolution ( σE) that degrades from 1.5 keV to 1.9 keV with increasing x-ray energy from 40 keV to 100 keV. With increasing input count rate, σE degrades by approximately 4 ·10-3 keV Mcps-1 mm2, which is, within error bars, the same for the different energies. The effect of charge sharing on the width of the response peak is found to be negligible.

  2. MUST detector

    International Nuclear Information System (INIS)

    Blumenfeld, Y.; Auger, F.; Sauvestre, J.E.

    1999-01-01

    The IPN-Orsay, in collaboration with the SPhN-Saclay and the DPTA Bruyeres, has built an array of 8 telescopes based on Si-strip technology for the study of direct reactions induced by radioactive beams. The detectors are described, along with the compact high density VXI electronics and the stand-alone data acquisition system developed in the laboratory. One telescope was tested using an 40 Ar beam and the measured performances are discussed. (authors)

  3. The ITk strips tracker for the phase-II upgrade of the ATLAS detector of the HL-LHC

    CERN Document Server

    Koutoulaki, Afroditi; The ATLAS collaboration

    2016-01-01

    The inner detector of the present ATLAS detector has been designed and developed to function in the environment of the present Large Hadron Collider (LHC). At the next-generation tracking detector proposed for the High Luminosity LHC (HL-LHC), the so-called ATLAS Phase-II Upgrade, the particle densities and radiation levels will be higher by as much as a factor of ten. The new detectors must be faster, they need to be more highly segmented, and covering more area. They also need to be more resistant to radiation, and they require much greater power delivery to the front-end systems. At the same time, they cannot introduce excess material which could undermine performance. For those reasons, the inner tracker of the ATLAS detector must be redesigned and rebuilt completely. The design of the ATLAS Upgrade inner tracker (ITk) has already been defined. It consists of several layers of silicon particle detectors. The innermost layers will be composed of silicon pixel sensors, and the outer layers will consist of s...

  4. Compact ion chamber based neutron detector

    Science.gov (United States)

    Derzon, Mark S.; Galambos, Paul C.; Renzi, Ronald F.

    2015-10-27

    A directional neutron detector has an ion chamber formed in a dielectric material; a signal electrode and a ground electrode formed in the ion chamber; a neutron absorbing material filling the ion chamber; readout circuitry which is electrically coupled to the signal and ground electrodes; and a signal processor electrically coupled to the readout circuitry. The ion chamber has a pair of substantially planar electrode surfaces. The chamber pressure of the neutron absorbing material is selected such that the reaction particle ion trail length for neutrons absorbed by the neutron absorbing material is equal to or less than the distance between the electrode surfaces. The signal processor is adapted to determine a path angle for each absorbed neutron based on the rise time of the corresponding pulse in a time-varying detector signal.

  5. Recent T980 Crystal Collimation Studies at the Tevatron Exploiting a Pixel Detector System and a Multi-strip Crystal Array

    CERN Document Server

    Still, D; Carrigan, R A; Drozhdin, A I; Johnson, T R; Mokhov, N V; Previtali, V; Rivera, R; Shiltsev, V; Zagel, J; Zvoda, V V; Mirarchi, D; Redaelli, S; Guidi, V; Mazzolari, A; Ivanov, Y M; Yazynin, I A; Chesnokov, Y A

    2012-01-01

    With the shutdown of the Tevatron, the T-980 crystal collimation experiment at Fermilab has been successfully completed. Results of dedicated beam studies in May 2011 are described in this paper. For these studies, two multi-strip crystals were installed in the vertical goniometer and an O-shaped crystal installed in a horizontal goniometer. A two-plane CMS pixel detector was also installed in order to enhance the experiment with the capability to image the profile of crystal channeled or multiple volume reflected beam. The experiment successfully imaged channeled beam from a crystal for 980-GeV protons for the first time. This new enhanced hardware yielded impressive results. The performance and characterization of the crystals studied have been very reproducible over time and consistent with simulations.

  6. Low material budget floating strip Micromegas for ion transmission radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, J., E-mail: jonathan.bortfeldt@cern.ch [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Biebel, O.; Flierl, B.; Hertenberger, R.; Klitzner, F.; Lösel, Ph. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Magallanes, L. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); University Hospital Heidelberg, Im Neuenheimer Feld 672, D-69120 Heidelberg (Germany); Müller, R. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Parodi, K. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); Heidelberg Ion-Beam Therapy Center, Im Neuenheimer Feld 450, D-69120 Heidelberg (Germany); Schlüter, T. [LMU Munich, Excellence Cluster Universe, Boltzmannstr. 2, D-85748 Garching (Germany); Voss, B. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstr. 1, D-64291 Darmstadt (Germany); Zibell, A. [JMU Würzburg, Sanderring 2, D-97070 Würzburg (Germany)

    2017-02-11

    Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7 MHz/cm{sup 2} with 100 μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encountered in medical ion transmission radiography or inner tracker applications. Recently we additionally developed Kapton-based floating strip Micromegas with two-dimensional strip readout, featuring an overall thickness of 0.011 X{sub 0}. These detectors were tested in high-rate proton and carbon-ion beams at the tandem accelerator in Garching and the Heidelberg Ion-Beam Therapy Center, operated with an optimized Ne:CF{sub 4} gas mixture. By coupling the Micromegas detectors to a new scintillator based range detector, ion transmission radiographies of PMMA and tissue-equivalent phantoms were acquired. The range detector with 18 layers is read out via wavelength shifting fibers, coupled to a multi-anode photomultiplier. We present the performance of the Micromegas detectors with respect to timing and single plane track reconstruction using the μTPC method. We discuss the range resolution of the scintillator range telescope and present the image reconstruction capabilities of the combined system.

  7. Aptamer-Based Lateral Flow Test Strip for Rapid Detection of Zearalenone in Corn Samples.

    Science.gov (United States)

    Wu, Shijia; Liu, Lihong; Duan, Nuo; Li, Qian; Zhou, You; Wang, Zhouping

    2018-02-28

    An aptamer-based lateral flow test strip was developed for the detection of zearalenone (ZEN). This assay was based on the competition for the aptamer between ZEN and its complementary sequence. Several experimental conditions that could influence sensitivity have been investigated, including the concentration of aptamer and NaCl used in the probe preparation, the mole ratio of streptavidin and biotinylated DNA used in the preparation of test line and control line, and the loading quantity of gold nanoparticles-aptamer conjugates (AuNPs-Apt). Under the optimal experimental conditions, we successfully detected ZEN within a detection range of 5-200 ng/mL and the visual limit of detection of 20 ng/mL. This aptamer-based strip was successfully applied to the determination of ZEN in spiked corn samples, and the recoveries were from 93.4% to 114.2%. All detections can be achieved within 5 min. The results demonstrated that the developed aptamer-based lateral flow test strip is a potential alternative tool for the rapid and sensitive detection of ZEN.

  8. Disposable Electrochemical Immunosensor Diagnosis Device Based on Nanoparticle Probe and Immunochromatographic Strip

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guodong; Lin, Ying-Ying; Wang, Jun; Wu, Hong; Wai, Chien M.; Lin, Yuehe

    2007-10-15

    We describe a disposable electrochemical immunosensor diagnosis device that is based on the immunochromatographic strip technique and an electrochemical immunoassay based on quantum dot (QD, CdS@ZnS) labels. The device takes advantage of the speed and low-cost of the conventional immunochromatographic strip test and the high-sensitivity of the nanoparticle-based electrochemical immunoassay. A sandwich immunoreaction was performed on the immunochromatographic strip, and the captured QD labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable-screen-printed electrode, which is embedded underneath the membrane on the test zone. The new device coupled with a portable electrochemical analyzer shows great promise for in-field and point-of-care quantitative testing of disease-related protein biomarkers. The parameters (e.g., voltammetric measurement of QD labels, antibody immobilization, the loading amount of QD-antibody, and the immunoreaction time) that govern the sensitivity and reproducibility of the device were optimized with IgG model analyte. The voltammetric response of the optimized device is highly linear over the range of 0.1 to 10 ng mL-1 IgG, and the limit of detection is estimated to be 30 pg mL-1 in association with a 7-min immunoreaction time. The detection limit was improved to 10 pg mL-1 using a 20-min immunoreaction time. The new disposable electrochemical diagnosis device thus provides a more user-friendly, rapid, clinically accurate, less expensive, and quantitative tool for protein detection.

  9. Analysis and comparison of the breakdown performance of semi-insulator and dielectric passivated Si strip detectors

    Science.gov (United States)

    Ranjan, Kirti; Bhardwaj, Ashutosh; Namrata; Chatterji, Sudeep; Srivastava, Ajay K.; Shivpuri, R. K.

    2002-12-01

    The harsh radiation environment in future high-energy physics (HEP) experiments like LHC provides a challenging task to the performance of Si microstrip detectors. Normal operating condition for silicon detectors in HEP experiments are in most cases not as favourable as for experiments in nuclear physics. In HEP experiments the detector may be exposed to moisture and other adverse atmospheric environment. It is therefore utmost important to protect the sensitive surfaces against such poisonous effects. These instabilities can be nearly eliminated and the performance of Si detectors can be improved by implementing suitably passivated metal-overhang structures. This paper presents the influence of the relative permittivity of the passivant on the breakdown performance of the Si detectors using computer simulations. The semi-insulator and the dielectric passivated metal-overhang structures are compared under optimal conditions. The influence of various parameters such as passivation layer thickness, junction depth, metal-overhang width, device depth, substrate resistivity and fixed oxide charge on the junction breakdown voltage of these structures is extensively studied. The results presented in this work clearly demonstrate the superiority of the metal-overhang structure design employing semi-insulator passivated structures over dielectric passivated ones in realising a given breakdown voltage. The effect of bulk damage caused by hadron environment in the passivated Si detectors is simulated, to a first order approximation, by varying effective carrier concentration (calculated using Hamburg Model) and minority carrier lifetime. This approach allows getting an insight of the device behaviour after radiation damage by evaluating the electric field distribution, and thus proves helpful in predicting some interesting results.

  10. Simulation study of liquid scintillator based 4π neutron detector

    International Nuclear Information System (INIS)

    Banerjee, K.; Kundu, S.; Bhattacharya, C.; Dey, A.; Bhattacharya, S.

    2004-01-01

    Neutron multiplicity detectors play an important role in deciphering the complexities of intermediate energy nucleus-nucleus reactions. Several neutron multiplicity detectors are in operation. As part of the super conducting cyclotron utilization project, it has been planned to make one liquid scintillator based neutron multiplicity detector at VECC, Kolkata. Here reported are initial results of the simulation study of the characteristics of a large liquid scintillator based neutron multiplicity detector

  11. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  12. Preliminary experimental investigation on induction voltage adder based on rolled strip pulse forming line

    International Nuclear Information System (INIS)

    Meng Zhipeng; Qian Baoliang; Yang Hanwu; Yang Shi; Li Song

    2011-01-01

    A technical solution for high power pulse generator which is based on both induction voltage adder (IVA) and rolled strip line is introduced. The induction cell is designed for a 10-stage IVA, its equivalent circuit is obtained and corresponding simulation research is carried out. To study the response characteristics of the induction cell, a rolled strip pulse forming line with an impedance of 3 Ω and pulse duration of 230 ns is fabricated as the voltage drive source. Experimental investigations on both the single induction cell and 4-stage IVA are carried out. The results show that the cell has good response characteristics. The current efficiency of the 4-stage IVA can reach about 80%, and the output voltage is about 4 times the magnitude of the input. In the repetitive condition, the sequence of 87 pulses at the frequency of about 5 Hz is obtained, which are well repeatable. (authors)

  13. An efficient Mindlin finite strip plate element based on assumed strain distribution

    Science.gov (United States)

    Chulya, Abhisak; Thompson, Robert L.

    1988-01-01

    A simple two node, linear, finite strip plate bending element based on Mindlin-Reissner plate theory for the analysis of very thin to thick bridges, plates, and axisymmetric shells is presented. The new transverse shear strains are assumed for constant distribution in the two node linear strip. The important aspect is the choice of the points that relate the nodal displacements and rotations through the locking transverse shear strains. The element stiffness matrix is explicitly formulated for efficient computation and ease in computer implementation. Numerical results showing the efficiency and predictive capability of the element for analyzing plates with different supports, loading conditions, and a wide range of thicknesses are given. The results show no sign of the shear locking phenomenon.

  14. Enzyme-Based Test Strips for Visual or Photographic Detection and Quantitation of Gaseous Sulfur Mustard.

    Science.gov (United States)

    Bidmanova, Sarka; Steiner, Mark-Steven; Stepan, Martin; Vymazalova, Kamila; Gruber, Michael A; Duerkop, Axel; Damborsky, Jiri; Prokop, Zbynek; Wolfbeis, Otto S

    2016-06-07

    Sulfur mustard is a chemical agent of high military and terroristic significance. No effective antidote exists, and sulfur mustard can be fairly easily produced in large quantity. Rapid field testing of sulfur mustard is highly desirable. Existing analytical devices for its detection are available but can suffer from low selectivity, laborious sample preparation, and/or the need for complex instrumentation. We describe a new kind of test strip for rapid detection of gaseous sulfur mustard that is based on its degradation by the enzyme haloalkane dehalogenase that is accompanied by a change of local pH. This change can be detected using pH indicators contained in the strips whose color changes from blue-green to yellow within 10 min. In addition to visual read-out, we also demonstrate quantitative reflectometric readout by using a conventional digital camera based on red-green-blue data acquisition. Organic haloalkanes, such as 1,2-dichloroethane, have a negligible interfering effect. The visual limit of detection is 20 μg/L, and the one for red-green-blue read-out is as low as 3 μg/L. The assays have good reproducibility ±6% and ±2% for interday assays and intraday assays, respectively. The strips can be stored for at least 6 months without loss of function. They are disposable and can be produced fairly rapidly and at low costs. Hence, they represent a promising tool for in-field detection of sulfur mustard.

  15. Quantum dot-based immunochromatography test strip for rapid, quantitative and sensitive detection of alpha fetoprotein.

    Science.gov (United States)

    Yang, Qiuhua; Gong, Xiaoqun; Song, Tao; Yang, Jiumin; Zhu, Shengjiang; Li, Yunhong; Cui, Ye; Li, Yingxin; Zhang, Bingbo; Chang, Jin

    2011-12-15

    Rapid, quantitative detection of tumor markers with high sensitivity and specificity is critical to clinical diagnosis and treatment of cancer. We describe here a novel portable fluorescent biosensor that integrates quantum dot (QD) with an immunochromatography test strip (ICTS) and a home-made test strip reader for detection of tumor markers in human serum. Alpha fetoprotein (AFP), which is valuable for diagnosis of primary hepatic carcinoma, is used as a model tumor marker to demonstrate the performance of the proposed immunosensor. The principle of this sensor is on the basis of a sandwich immunoreaction that was performed on an ICTS. The fluorescence intensity of captured QD labels on the test line and control line served as signals was determined by the home-made test strip reader. The strong luminescence and robust photostability of QDs combined with the promising advantages of an ICTS and sensitive detection with the test strip reader result in good performance. Under optimal conditions, this biosensor is capable of detecting as low as 1 ng/mL AFP standard analyte in 10 min with only 50 μL sample volume. Furthermore, 1000 clinical human serum samples were tested by both the QD-based ICTS and a commercial electrochemiluminescence immunoassay AFP kit simultaneously to estimate the sensitivity, specificity and concordance of the assays. Results showed high consistency except for 24 false positive cases (false positive rate 3.92%) and 17 false negative cases (false negative rate 4.38%); the error rate was 4.10% in all. This demonstrates that the QD-based ICTS is capable of rapid, sensitive, and quantitative detection of AFP and shows a great promise for point-of-care testing of other tumor markers. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Characterization of BJT-based particle detectors

    International Nuclear Information System (INIS)

    Piemonte, C.; Batignani, G.; Bettarini, S.; Bondioli, M.; Boscardin, M.; Bosisio, L.; Dalla Betta, G.-F.; Dittongo, S.; Forti, F.; Giorgi, M.; Gregori, P.; Rachevskaia, I.; Ronchin, S.; Zorzi, N.

    2004-01-01

    We report on the static and dynamic behavior of BJT-based particle detectors realized on high-resistivity silicon. Several prototypes, featuring different doping profiles and geometries, have been fabricated at ITC-irst (Trento, Italy). These devices have been thoroughly characterized from the electrical viewpoint, and, in order to understand the fundamental parameters of the structure, device simulations have been performed, whose results are in very good agreement with experimental data. Preliminary functional measurements have been carried out by using a 109Cd source excitation

  17. A fast, low-power, 6-bit SAR ADC for readout of strip detectors in the LHCb Upgrade experiment.

    CERN Document Server

    Firlej, M; Idzik, M; Moron, J; Swientek, K

    2014-01-01

    The readout of silicon strip sensors in the upgraded Tracker System of Large Hadron Collider beauty (LHCb) experiment will require a novel complex Application Specific Integrated Circuit (ASIC). The ASIC will extract and digitise analogue signal from the sensor and subsequently will perform digital processing and serial data transmission. One of the key processing blocks, placed in each channel, will be an Analogue to Digital Converter (ADC). A prototype of fast, low-power 6-bit Successive Approximation Register (SAR) ADC was designed, fabricated and tested. The measurements of ADC prototypes confirmed simulation results showing excellent overall performance. In particular, very good resolution with Effective Number Of Bits (ENOB) 5.85 was obtained together with very low power consumption of 0.35 mW at 40 MS/s sampling rate. The results of the performed static and dynamic measurements confirm excellent ADC operation for higher sampling rates up to 80 MS/s.

  18. A fast, low-power, 6-bit SAR ADC for readout of strip detectors in the LHCb Upgrade experiment

    Science.gov (United States)

    Firlej, M.; Fiutowski, T.; Idzik, M.; Moron, J.; Swientek, K.

    2014-07-01

    The readout of silicon strip sensors in the upgraded Tracker System of Large Hadron Collider beauty (LHCb) experiment will require a novel complex Application Specific Integrated Circuit (ASIC). The ASIC will extract and digitise analogue signal from the sensor and subsequently will perform digital processing and serial data transmission. One of the key processing blocks, placed in each channel, will be an Analogue to Digital Converter (ADC). A prototype of fast, low-power 6-bit Successive Approximation Register (SAR) ADC was designed, fabricated and tested. The measurements of ADC prototypes confirmed simulation results showing excellent overall performance. In particular, very good resolution with Effective Number Of Bits (ENOB) 5.85 was obtained together with very low power consumption of 0.35 mW at 40 MS/s sampling rate. The results of the performed static and dynamic measurements confirm excellent ADC operation for higher sampling rates up to 80 MS/s.

  19. Extended Kalman Filter Based Neural Networks Controller For Hot Strip Rolling mill

    International Nuclear Information System (INIS)

    Moussaoui, A. K.; Abbassi, H. A.; Bouazza, S.

    2008-01-01

    The present paper deals with the application of an Extended Kalman filter based adaptive Neural-Network control scheme to improve the performance of a hot strip rolling mill. The suggested Neural Network model was implemented using Bayesian Evidence based training algorithm. The control input was estimated iteratively by an on-line extended Kalman filter updating scheme basing on the inversion of the learned neural networks model. The performance of the controller is evaluated using an accurate model estimated from real rolling mill input/output data, and the usefulness of the suggested method is proved

  20. Folded Elastic Strip-Based Triboelectric Nanogenerator for Harvesting Human Motion Energy for Multiple Applications.

    Science.gov (United States)

    Kang, Yue; Wang, Bo; Dai, Shuge; Liu, Guanlin; Pu, Yanping; Hu, Chenguo

    2015-09-16

    A folded elastic strip-based triboelectric nanogenerator (FS-TENG) made from two folded double-layer elastic strips of Al/PET and PTFE/PET can achieve multiple functions by low frequency mechanical motion. A single FS-TENG with strip width of 3 cm and length of 27 cm can generate a maximum output current, open-circuit voltage, and peak power of 55 μA, 840 V, and 7.33 mW at deformation frequency of 4 Hz with amplitude of 2.5 cm, respectively. This FS-TENG can work as a weight sensor due to its good elasticity. An integrated generator assembled by four FS-TENGs (IFS-TENG) can harvest the energy of human motion like flapping hands and walking steps. In addition, the IFS-TENG combined with electromagnetically induced electricity can achieve a completely self-driven doorbell with flashing lights. Moreover, a box-like generator integrated by four IFS-TENGs inside can work in horizontal or random motion modes and can be improved to harvest energy in all directions. This work promotes the research of completely self-driven systems and energy harvesting of human motion for applications in our daily life.

  1. A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples.

    Science.gov (United States)

    Zhang, Guilan; Zhu, Chao; Huang, Yafei; Yan, Jiao; Chen, Ailiang

    2018-01-31

    Ochratoxin A (OTA) is a mycotoxin identified as a contaminant in grains and wine throughout the world, and convenient, rapid and sensitive detection methods for OTA have been a long-felt need for food safety monitoring. Herein, we presented a new competitive format based lateral flow strip fluorescent aptasensor for one-step determination of OTA in corn samples. Briefly, biotin-cDNA was immobilized on the surface of a nitrocellulose filter on the test line. Without OTA, Cy5-labeled aptamer combined with complementary strands formed a stable double helix. In the presence of OTA, however, the Cy5-aptamer/OTA complexes were generated, and therefore less free aptamer was captured in the test zone, leading to an obvious decrease in fluorescent signals on the test line. The test strip showed an excellent linear relationship in the range from 1 ng·mL -1 to 1000 ng·mL -1 with the LOD of 0.40 ng·mL -1 , IC 15 value of 3.46 ng·mL -1 and recoveries from 96.4% to 104.67% in spiked corn samples. Thus, the strip sensor developed in this study is an acceptable alternative for rapid detection of the OTA level in grain samples.

  2. A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples

    Directory of Open Access Journals (Sweden)

    Guilan Zhang

    2018-01-01

    Full Text Available Ochratoxin A (OTA is a mycotoxin identified as a contaminant in grains and wine throughout the world, and convenient, rapid and sensitive detection methods for OTA have been a long-felt need for food safety monitoring. Herein, we presented a new competitive format based lateral flow strip fluorescent aptasensor for one-step determination of OTA in corn samples. Briefly, biotin-cDNA was immobilized on the surface of a nitrocellulose filter on the test line. Without OTA, Cy5-labeled aptamer combined with complementary strands formed a stable double helix. In the presence of OTA, however, the Cy5-aptamer/OTA complexes were generated, and therefore less free aptamer was captured in the test zone, leading to an obvious decrease in fluorescent signals on the test line. The test strip showed an excellent linear relationship in the range from 1 ng·mL−1 to 1000 ng·mL−1 with the LOD of 0.40 ng·mL−1, IC15 value of 3.46 ng·mL−1 and recoveries from 96.4% to 104.67% in spiked corn samples. Thus, the strip sensor developed in this study is an acceptable alternative for rapid detection of the OTA level in grain samples.

  3. Polarimetric Edge Detector Based on the Complex Wishart Distribution

    DEFF Research Database (Denmark)

    Skriver, Henning; Schou, Jesper; Nielsen, Allan Aasbjerg

    2001-01-01

    A new edge detector for polarimetric SAR data has been developed. The edge detector is based on a newly developed test statistic for equality of two complex covariance matrices following the complex Wishart distribution and an associated asymptotic probability for the test statistic. The new...... for the full polarimetric detector compared to single channel approaches....

  4. Determination of monoamine neurotransmitters in human urine by carrier-mediated liquid-phase microextraction based on solidification of stripping phase.

    Science.gov (United States)

    Jiang, Liwei; Chen, Yibang; Chen, Yejun; Ma, Ming; Tan, Yueming; Tang, Hao; Chen, Bo

    2015-11-01

    A novel method was developed for the analysis of monoamine neurotransmitters (MNTs) in human urine by carrier-mediated liquid-phase microextraction based on solidification of stripping phase method (CM-LPME-SSP) coupled with high performance liquid chromatography-electrochemical detector (HPLC-ECD). By adding an appropriate carrier in organic phase, simultaneous extraction of hydrophilic analytes, MNTs, with high enrichment factors (22.6-36.1 folds) and excellent sample cleanup was achieved. A new strategy, solidifying the aqueous stripping phase in the back-extraction process, was developed to facilitate the collection of the stripping phase as small as a few microliters. Combined with HPLC-ECD analysis, the linear ranges of the established method were 0.015-2.0 μg/mL for NE, E, DA, and 0.020-2.0 μg/mL for 5-HT. The limits of detection and quantification were in the range of 5.5-10.8 ng/mL and 15-20 ng/mL, respectively. The relative recoveries were in the range of 87-108%, with intraday and interday relative standard deviations lower than 13%. This method was successfully applied to analysis of MNTs in real urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Design studies of the ATLAS muon Level-1 trigger based on the MDT detector for the LHC upgrade

    CERN Document Server

    Sasaki, O; Nagano, K; Ishino, M; Ikeno, M; Bendtz, K; Domae, T; Sakamoto, H; Kawamoto, T; Fukunaga, C; Shichi, H; Tomoto, M; Sugaya, Y; Tokunaga, K; Kurashige, H; 10.1088/1748-0221/5/12/C12021

    2010-01-01

    The present muon Level-1 trigger of the ATLAS detector is given by dedicated detectors; RPC and TGC chambers in barrel and end-cap regions, respectively. The Monitored Drift Tube (MDT) chambers and the Cathode-Strip Chambers (CSC) are used for precision measurements of muon tracks. The performance of the muon Level-1 trigger is limited by the momentum resolution of the trigger chambers. In order to improve the trigger performance, a muon track finding scheme based on MDT signals is envisaged. Studies of the scheme and the algorithm are presented. The trigger latency is estimated to be approximately 3 μs

  6. Design studies of the ATLAS muon Level-1 trigger based on the MDT detector for the LHC upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, O; Suzuki, Y; Nagano, K; Ishino, M; Ikeno, M [High Energy Accelerator Research Organization (KEK), Institute of Particle and Nuclear Studies, 1-1 Oho, Tsukuba-shi, Ibaraki-ken 305-0801 (Japan); Bendtz, K; Domae, T; Sakamoto, H; Kawamoto, T [University of Tokyo, International Center for Elementary Particle Physics and Department of Physics, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Fukunaga, C [Tokyo Metropolitan University, Graduate School of Science and Technology, 1-1 Minami-Osawa, Hachioji, Tokyo 113-0033 (Japan); Shichi, H; Tomoto, M [Nagoya University, Graduate School of Science, Furo-Cho, Chikusa-ku 464-8602 (Japan); Sugaya, Y [Osaka University, Graduate School of Science, 1-1 Machikaneyama-machi, Toyonaka, Osaka 560-0043 (Japan); Tokunaga, K; Kurashige, H, E-mail: osamu.sasaki@kek.jp [Kobe University, Graduate School of Science, 1-1 Rokkodai-cho, Nada-ku, Kobe 621-8522 (Japan)

    2010-12-15

    The present muon Level-1 trigger of the ATLAS detector is given by dedicated detectors; RPC and TGC chambers in barrel and end-cap regions, respectively. The Monitored Drift Tube (MDT) chambers and the Cathode-Strip Chambers (CSC) are used for precision measurements of muon tracks. The performance of the muon Level-1 trigger is limited by the momentum resolution of the trigger chambers. In order to improve the trigger performance, a muon track finding scheme based on MDT signals is envisaged. Studies of the scheme and the algorithm are presented. The trigger latency is estimated to be approximately 3 {mu}s.

  7. Application of a SERS-based lateral flow immunoassay strip for the rapid and sensitive detection of staphylococcal enterotoxin B

    Science.gov (United States)

    Hwang, Joonki; Lee, Sangyeop; Choo, Jaebum

    2016-06-01

    A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner.A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as

  8. The CMS Silicon Strip Tracker

    CERN Document Server

    Azzurri, P

    2005-01-01

    With over 200 square meters of sensitive Silicon and almost 10 million readout channels, the Silicon Strip Tracker of the CMS experiment at the LHC will be the largest Silicon strip detector ever built. The design, construction and expected performance of the CMS Tracker is reviewed in the following.

  9. The Data Quality Monitoring for the CMS Silicon Strip Tracker

    CERN Document Server

    Adler, V; Bainbridge, R; Benucci, L; Borgia, M A; Borrello, L; Cole, J; Cripps, N; Delmeire, E; Dero, V; Dutta, S; Giordano, D; Hammad, G H; Hashemi, H; Le Bihan, A C; Le Bourgeois, M; Palmonari, F; Pierro, A; Zito, G

    2009-01-01

    The CMS Silicon Strip Tracker (SST), consisting of more than 10 million channels, is organized in about 15,000 detector modules and it is the largest silicon strip tracker ever built for high energy physics experiments. The Data Quality Monitoring system for the Tracker has been developed within the CMS Software framework. More than 100,000 monitorable quantities need to be managed by the DQM system that organizes them in a hierarchical structure reflecting the detector arrangement in subcomponents and the various levels of data processing. Monitorable quantities computed at the level of individual detectors are processed to extract automatic quality checks and summary results that can be visualized with specialized graphical user interfaces. In view of the great complexity of the CMS Tracker detector the standard visualization tools based on histograms have been complemented with 2 and 3 dimensional graphical images of the subdetector that can show the whole detector down to single channel resolution. The fu...

  10. An FPGA-Based Pulse Pile-up Rejection Technique for Photon Counting Imaging Detectors

    International Nuclear Information System (INIS)

    Hu Kun; Li Feng; Chen Lian; Jin Ge; Liang Fu-Tian

    2015-01-01

    A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. The method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are introduced in detail. The photon counting imaging detector comprises a micro-channel plate (MCP) stack, and a wedge and strip anode (WSA). The resolution mask pattern in front of the MCP can be reconstructed after data processing in the FPGA. For high count rates, the rejection design can effectively reduce the impact of the pulse pile-up on the image. The resolution can reach up to 140 μm. The pulse pile-up rejection design can also be applied to high-energy physics and particle detection. (paper)

  11. [Calorimeter based detectors for high energy hadron colliders

    International Nuclear Information System (INIS)

    1992-01-01

    This document provides a progress report on research that has been conducted under DOE Grant DEFG0292ER40697 for the past year, and describes proposed work for the second year of this 8 year grant starting November 15, 1992. Personnel supported by the contract include 4 faculty, 1 research faculty, 4 postdocs, and 9 graduate students. The work under this grant has in the past been directed in two complementary directions -- DO at Fermilab, and the second SSC detector GEM. A major effort has been towards the construction and commissioning of the new Fermilab Collider detector DO, including design, construction, testing, the commissioning of the central tracking and the central calorimeters. The first DO run is now underway, with data taking and analysis of the first events. Trigger algorithms, data acquisition, calibration of tracking and calorimetry, data scanning and analysis, and planning for future upgrades of the DO detector with the advent of the FNAL Main Injector are all involved. The other effort supported by this grant has been towards the design of GEM, a large and general-purpose SSC detector with special emphasis on accurate muon measurement over a large solid angle. This effort will culminate this year in the presentation to the SSC laboratory of the GEM Technical Design Report. Contributions are being made to the detector design, coordination, and physics simulation studies with special emphasis on muon final states. Collaboration with the RD5 group at CERN to study muon punch through and to test cathode strip chamber prototypes was begun

  12. Cluster-based Data Gathering in Long-Strip Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    FANG, W.

    2012-02-01

    Full Text Available This paper investigates a special class of wireless sensor networks that are different from traditional ones in that the sensor nodes in this class of networks are deployed along narrowly elongated geographical areas and form a long-strip topology. According to hardware capabilities of current sensor nodes, a cluster-based protocol for reliable and efficient data gathering in long-strip wireless sensor networks (LSWSN is proposed. A well-distributed cluster-based architecture is first formed in the whole network through contention-based cluster head election. Cluster heads are responsible for coordination among the nodes within their clusters and aggregation of their sensory data, as well as transmission the data to the sink node on behalf of their own clusters. The intra-cluster coordination is based on the traditional TDMA schedule, in which the inter-cluster interference caused by the border nodes is solved by the multi-channel communication technique. The cluster reporting is based on the CSMA contention, in which a connected overlay network is formed by relay nodes to forward the data from the cluster heads through multi-hops to the sink node. The relay nodes are non-uniformly deployed to resolve the energy-hole problem which is extremely serious in the LSWSN. Extensive simulation results illuminate the distinguished performance of the proposed protocol.

  13. The CMS Silicon Strip Tracker performance using cosmic ray data

    CERN Document Server

    Borrello, L

    2010-01-01

    The CMS Silicon Strip Tracker is the largest tracking system based on silicon detector technology ever built for high energy physics experiment. It consists of 24,244 single-sided micro-strip sensors for a total active area of 198 $m^2$ and about 10 million readout channels. The SST was installed inside CMS in December 2007, commissioned during summer 2008 and then it participated along with other CMS subdetectors in several cosmic muon data taking runs. The commissioning strategy, operational experience and detector performance results will be presented.

  14. Ionization-based detectors for gas chromatography.

    Science.gov (United States)

    Poole, Colin F

    2015-11-20

    The gas phase ionization detectors are the most widely used detectors for gas chromatography. The column and makeup gases commonly used in gas chromatography are near perfect insulators. This facilitates the detection of a minute number of charge carriers facilitating the use of ionization mechanisms of low efficiency while providing high sensitivity. The main ionization mechanism discussed in this report are combustion in a hydrogen diffusion flame (flame ionization detector), surface ionization in a plasma (thermionic ionization detector), photon ionization (photoionization detector and pulsed discharge helium ionization detector), attachment of thermal electrons (electron-capture detector), and ionization by collision with metastable helium species (helium ionization detector). The design, response characteristics, response mechanism, and suitability for fast gas chromatography are the main features summarized in this report. Mass spectrometric detection and atomic emission detection, which could be considered as ionization detectors of a more sophisticated and complex design, are not discussed in this report. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Vertex detectors

    International Nuclear Information System (INIS)

    Lueth, V.

    1992-07-01

    The purpose of a vertex detector is to measure position and angles of charged particle tracks to sufficient precision so as to be able to separate tracks originating from decay vertices from those produced at the interaction vertex. Such measurements are interesting because they permit the detection of weakly decaying particles with lifetimes down to 10 -13 s, among them the τ lepton and charm and beauty hadrons. These two lectures are intended to introduce the reader to the different techniques for the detection of secondary vertices that have been developed over the past decades. The first lecture includes a brief introduction to the methods used to detect secondary vertices and to estimate particle lifetimes. It describes the traditional technologies, based on photographic recording in emulsions and on film of bubble chambers, and introduces fast electronic registration of signals derived from scintillating fibers, drift chambers and gaseous micro-strip chambers. The second lecture is devoted to solid state detectors. It begins with a brief introduction into semiconductor devices, and then describes the application of large arrays of strip and pixel diodes for charged particle tracking. These lectures can only serve as an introduction the topic of vertex detectors. Time and space do not allow for an in-depth coverage of many of the interesting aspects of vertex detector design and operation

  16. Multiplexed Detection of Tumor Markers with Multicolor Polymer Dot-Based Immunochromatography Test Strip.

    Science.gov (United States)

    Fang, Chia-Chia; Chou, Chia-Cheng; Yang, Yong-Quan; Wei-Kai, Tsai; Wang, Yeng-Tseng; Chan, Yang-Hsiang

    2018-02-06

    There have been ongoing efforts to develop more sensitive and fast quantitative screening of cancer markers by use of fluorometric immunochromatographic test strips (ICTS) since the remarkable advances in fluorescent nanomaterials. Semiconducting polymer dots (Pdots) have recently emerged as a new type of biocompatible fluorescent probe with extraordinary brightness which is suitable for biological and clinical use. Here, we developed Pdot-based ICTS for quantitative rapid screening of prostate-specific antigen (PSA), α-fetoprotein (AFP), and carcinoembryonic antigen (CEA) in 10 min. Through use of the ultrahigh fluorescence brightness of Pdots, this immunosensor enabled much better detection sensitivity (2.05, 3.30, and 4.92 pg/mL for PSA, AFP, and CEA, respectively), in which the detection limit is at least 2 orders of magnitude lower than that of conventional fluorometric ICTS. Furthermore, we performed proof-of-concept experiments for simultaneous determination of multiple tumor markers in a single test strip. These results demonstrated that this Pdot-based ICTS platform is a promising candidate for developing new generations of point-of-care diagnostics. To the best of our knowledge, this is the first example of Pdot-based ICTS with multiplexing capability.

  17. The design of fast analog channels for the readout of strip detectors in the inner layers of the SuperB SVT

    Science.gov (United States)

    Gaioni, L.; Manghisoni, M.; Ratti, L.; Re, V.; Traversi, G.

    2013-08-01

    Six layers of microstrip detectors are foreseen in the present baseline design of the SuperB Silicon Vertex Tracker. Different strip pitches and lengths will be used in the various SVT layers; however, the capability of standing a high background rate and of operating with high hit detection efficiency will be a common feature of the innermost layers. These requirements set the need for a readout chip with analog channels with a short signal shaping time (25-200 ns in layers 0-3) to achieve an adequate time stamp resolution and a small pulse overlap. These channels are also required to provide a 4-bit hit amplitude resolution for dE / dx measurements. A new chip is being designed in a 130 nm CMOS process to comply with these specifications. This paper discusses the solutions that are adopted in this chip for the various blocks of the analog channels, and will present the simulation results for the current design along with the expected performance in terms of parameters such as signal-to-noise ratio, dynamic range, linearity, power dissipation.

  18. Pillar-structured neutron detector based multiplicity system

    Science.gov (United States)

    Murphy, John W.; Shao, Qinghui; Voss, Lars F.; Kerr, Phil L.; Fabris, Lorenzo; Conway, Adam M.; Nikolic, Rebecca J.

    2018-01-01

    This work demonstrates the potential of silicon pillars filled with boron-10 as a sensor technology for a compact and portable neutron multiplicity system. Solid-state, semiconductor based neutron detectors may enable completely new detector form factors, offer an alternate approach to helium-3 based systems, and reduce detector weight and volume requirements. Thirty-two pillar-structured neutron detectors were assembled into a system with an active area of over 20 cm2 and were used in this work to demonstrate the feasibility of this sensor technology as a potential replacement for helium-3 based gas detectors. Multiplicity measurements were successfully carried out using a californium-252 neutron source, in which the source mass, system efficiency, and die-away time were determined. This demonstration shows that these solid-state detectors could allow for a more compact and portable system that could be used for special nuclear material identification in the field.

  19. Photosensitive Strip RETHGEM

    CERN Document Server

    Peskov, Vladimir; Nappi, E.; Oliveira, R.; Paic, G.; Pietropaolo, F.; Picchi, P.

    2008-01-01

    An innovative photosensitive gaseous detector, consisting of a GEM like amplification structure with double layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our latest designs, the inner electrode consists of a metallic grid and the outer one is made of resistive strips; the latter are manufactured by a screen printing technology on the top of the metallic strips grid The inner metallic grid is used for 2D position measurements whereas the resistive layer provides an efficient spark protected operation at high gains - close to the breakdown limit. Detectors with active areas of 10cm x10cm and 10cm x20cm were tested under various conditions including the operation in photosensitive gas mixtures containing ethylferrocene or TMAE vapors. The new technique could have many applications requiring robust and reliable large area detectors for UV visualization, as for example, in Cherenkov imaging devices.

  20. New Position Algorithms for the 3-D CZT Drift Detector

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Carl; Kuvvetli, Irfan

    2017-01-01

    The 3-D position sensitive CZT detector for high-energy astrophysics developed at DTU has been investigated with a digitizer readout system. The 3-D CZT detector is based on the CZT drift-strip detector principle and was fabricated using a REDLEN CZT crystal (20 mm x 20 mm x 5 mm). The detector...... cathode strips. For the characterization work, we used a DAQ system with a 16 channels 250-MHz 14-b digitizer, SIS3316. It allowed us to analyze the pulse shapes of the signals from four detector cells at a time. The 3-D CZT setup was characterized with a finely collimated radioactive source of Cs-137...

  1. Conversational Implicature of Peanuts Comic Strip Based on Grice’s Maxim Theory

    Directory of Open Access Journals (Sweden)

    Muhartoyo Muhartoyo

    2013-04-01

    Full Text Available This article discusses about conversational implicature that occurs in Peanuts comic strips. The objectives of this study are to find out the implied meaning in the conversation between Charlie Brown with Lucy van Pelt and Lucy van Pelt with Linus van Pelt to evaluate the existence of maxim flouting and maxim violating in those conversations in relation to the four maxims such as quantity, quality, relation, and manner. Likewise, this study attempts to find out the reason for using conversational implicature in a comic strip. The writers uses a qualitative method with library research concerning to Grice’s maxim theory to analyze the conversational implicature. Based on the analysis, it can be concluded that all the comics that comprise 14 comics generate conversational implicature since all the characters breach rules of maxim. The result of this analysis shows that flouting maxim of manner has the highest occurrence of conversational implicature and the least occurrences belong to flouting maxim of relation and violating maxim of quantity. Moreover, the writers concludes that to make a successful communication ideally the speaker and the hearer to cooperate in the conversation by saying explicitly so the hearer can grasp the meaning as the goal of communication is to deliver a message to the hearer.  

  2. Study of the physical processes involved in the operating mode of the micro-strips gas detector Micromegas; Analyse des phenomenes physiques lies au fonctionnement du detecteur gazeux a micropistes micromegas

    Energy Technology Data Exchange (ETDEWEB)

    Barouch, G

    2001-04-01

    Micromegas is a micro-strip gaseous detector invented in 1996. It consists of two volumes of gas separated by a micro-mesh. The first volume of gas, 3 mm thick, is used to liberate ionization electrons from the incident charged particle. In the second volume, only 100 {mu}m thick, an avalanche phenomenon amplifies the electrons produced in the first volume. Strips printed on an insulating substrate collect the electrons from the avalanche. The geometrical configuration of Micromegas showed many advantages. The short anode-cathode distance combined with a high granularity provide high rate capabilities due to a fast collection of ions produced during the avalanche development. Moreover, the possibility to localize the avalanche with strips printed about every hundreds of micrometers allows to measure the position of the incident particle with a good resolution. In this work, experimental tests of Micromegas are presented along with detailed Monte Carlo simulations used to understand and optimize the detector's performances. The prototypes were tested several times at the PS accelerator at CERN. The analysis of the date showed a stable and efficient behavior of Micromegas combined with an excellent space resolution. In fact, spatial resolutions of less than 15 {mu}m were obtained. In parallel with the in-beam tests, several simulations have been developed in order to gain a better understanding of the detector's response. (author)

  3. Neutron Detection with Water Cerenkov Based Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Dazeley, S; Bernstein, A; Bowden, N; Carr, D; Ouedraogo, S; Svoboda, R; Sweany, M; Tripathi, M

    2009-05-13

    Legitimate cross border trade involves the transport of an enormous number of cargo containers. Especially following the September 11 attacks, it has become an international priority to verify that these containers are not transporting Special Nuclear Material (SNM) without impeding legitimate trade. Fission events from SNM produce a number of neutrons and MeV-scale gammas correlated in time. The observation of consistent time correlations between neutrons and gammas emitted from a cargo container could, therefore, constitute a robust signature for SNM, since this time coincident signature stands out strongly against the higher rate of uncorrelated gamma-ray backgrounds from the local environment. We are developing a cost effective way to build very large neutron detectors for this purpose. We have recently completed the construction of two new water Cherenkov detectors, a 250 liter prototype and a new 4 ton detector. We present both the results from our prototype detector and an update on the newly commissioned large detector. We will also present pictures from the construction and outline our future detector development plans.

  4. An Improved VI-CFAR Detector Based on GOS

    Directory of Open Access Journals (Sweden)

    Zhao Likai

    2016-01-01

    Full Text Available In combination with the advantages of CA-CFAR, GO-CFAR and SO-CFAR algorithm, the VI-CFAR has strong adaptability both in homogeneous and non-homogeneous environment. However, if the interfering targets are present in both the halves of the reference sliding windows, the use of the window with the smallest mean is affected by them and therefore results in a performance degradation. In order to overcome the shortcoming, an improved VI-CFAR detector based on GOS (IVI-CFAR is proposed in this paper. We introduce the IVI-CFAR detector and make performance simulation and analysis in homogenous and non-homogenous environment. In the homogeneous environment, the IVI-CFAR detector has some CFAR loss relative to the CA-CFAR detector. In the clutter edge environment, the IVI-CFAR detector keeps the good performance of the VI-CFAR detector. In multiple interfering targets environment, the IVI-CFAR detector performs robustly, which is similar to the OS-CFAR detector. In addition, the IVI-CFAR detector shortens the sample sorting time of the OS-CFARR detector.

  5. Micro Surface Defect Detection Method for Silicon Steel Strip Based on Saliency Convex Active Contour Model

    Directory of Open Access Journals (Sweden)

    Kechen Song

    2013-01-01

    Full Text Available Accurate detection of surface defect is an indispensable section in steel surface inspection system. In order to detect the micro surface defect of silicon steel strip, a new detection method based on saliency convex active contour model is proposed. In the proposed method, visual saliency extraction is employed to suppress the clutter background for the purpose of highlighting the potential objects. The extracted saliency map is then exploited as a feature, which is fused into a convex energy minimization function of local-based active contour. Meanwhile, a numerical minimization algorithm is introduced to separate the micro surface defects from cluttered background. Experimental results demonstrate that the proposed method presents good performance for detecting micro surface defects including spot-defect and steel-pit-defect. Even in the cluttered background, the proposed method detects almost all of the microdefects without any false objects.

  6. Elastic strips

    OpenAIRE

    Chubelaschwili, David; Pinkall, Ulrich

    2010-01-01

    Motivated by the problem of finding an explicit description of a developable narrow Moebius strip of minimal bending energy, which was first formulated by M. Sadowsky in 1930, we will develop the theory of elastic strips. Recently E.L. Starostin and G.H.M. van der Heijden found a numerical description for an elastic Moebius strip, but did not give an integrable solution. We derive two conservation laws, which describe the equilibrium equations of elastic strips. In applying these laws we find...

  7. GaN-based PIN alpha particle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Wang Guo [Peking University, Shenzhen Graduate School, Guangdong Shenzhen 518055 (China); Peking University, Beijing, 100871 (China); Fu Kai; Yao Changsheng [Suzhou Institute of Nano-tech and Nano-bionics, Chinese Academy of Science, Jiangsu Suzhou 215123 (China); Su Dan; Zhang Guoguang [China Institute of Atomic Energy, Beijing 102413 (China); Wang Jinyan [Peking University, Beijing, 100871 (China); Lu Min, E-mail: mlu2006@sinano.ac.cn [Suzhou Institute of Nano-tech and Nano-bionics, Chinese Academy of Science, Jiangsu Suzhou 215123 (China)

    2012-01-21

    GaN-based PIN alpha particle detectors are studied in this article. The electrical properties of detectors have been investigated, such as current-voltage (I-V) and capacitance-voltage (C-V). The reverse current of all detectors is in nA range applied at 30 V, which is suitable for detector operation. The charge collection efficiency (CCE) is measured to be approximately 80% but the energy resolution is calculated to be about 40% mostly because the intrinsic layer is not sufficiently thick enough.

  8. Time-based position estimation in monolithic scintillator detectors

    NARCIS (Netherlands)

    Tabacchini, V.; Borghi, G.; Schaart, D.R.

    2015-01-01

    Gamma-ray detectors based on bright monolithic scintillation crystals coupled to pixelated photodetectors are currently being considered for several applications in the medical imaging field. In a typical monolithic detector, both the light intensity and the time of arrival of the earliest

  9. Neutron detection with water Cerenkov based detectors

    International Nuclear Information System (INIS)

    Dazeley, S.; Bernstein, A.; Bowden, N.; Carr, D.; Ouedraogo, S.; Svoboda, R.; Sweany, M.; Tripathi, M.

    2009-01-01

    Legitimate cross border trade involves the transport of an enormous number of cargo containers. Especially following the September 11 attacks, it has become an international priority to verify that these containers are not transporting Special Nuclear Material (SNM) without impeding legitimate trade. Fission events from SNM produce a number of neutrons and MeV-scale gammas correlated in time. The observation of consistent time correlations between neutrons and gammas emitted from a cargo container could, therefore, constitute a robust signature for SNM, since this time coincident signature stands out strongly against the higher rate of uncorrelated gamma-ray backgrounds from the local environment. We are developing a cost effective way to build very large neutron detectors for this purpose. We have recently completed the construction of two new water Cherenkov detectors, a 250 liter prototype and a new 4-ton detector. The 250-liter prototype uses an ultra-pure water detection medium doped with a small amount of gadolinium tri-chloride (0.2%). A 55 μCi 252 Cf neutron source was placed at a distance of 1 meter from the detector behind a 2 inch thick wall of lead. The presence of the source is easily discernible from the background in both the uncorrelated count rate and the correlated one. The 4-ton detector will shortly undergo filling and testing

  10. A new metaheuristic genetic-based placement algorithm for 2D strip packing

    Science.gov (United States)

    Thomas, Jaya; Chaudhari, Narendra S.

    2014-02-01

    Given a container of fixed width, infinite height and a set of rectangular block, the 2D-strip packing problem consists of orthogonally placing all the rectangles such that the height is minimized. The position is subject to confinement of no overlapping of blocks. The problem is a complex NP-hard combinatorial optimization, thus a heuristic based on genetic algorithm is proposed to solve it. In this paper, we give a hybrid approach which combined genetic encoding and evolution scheme with the proposed placement approach. Such a combination resulted in better population evolution and faster solution convergence to optimal. The approach is subjected to a comprehensive test using benchmark instances. The computation results validate the solution and the effectiveness of the approach.

  11. Bandwidth and Gain Enhancement of Patch Antenna with Stacked Parasitic Strips Based on LTCC Technology

    Directory of Open Access Journals (Sweden)

    Li Li

    2014-01-01

    Full Text Available A compact patch antenna with stacked parasitic strips (SPSs based on low temperature cofired ceramic (LTCC technology is presented. By adding three pairs of SPSs above the traditional patch antenna, multiple resonant modes are excited to broaden the bandwidth. At the same time, the SPSs act as directors to guide the antenna radiation toward broadside direction to enhance the gain. The measured results show that the prototype antenna achieves an impedance bandwidth of 16% for S11<-10 dB (32.1–37.9 GHz and a maximum gain of about 8 dBi at 35 GHz. Furthermore, the radiation patterns and gain are relatively stable within the operating bandwidth. The total volume of the antenna is only 8 × 8 × 1.1 mm3.

  12. Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor

    Directory of Open Access Journals (Sweden)

    Chuanlai Xu

    2013-03-01

    Full Text Available In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water.

  13. Reduction of Residual Stress for High-Strength Low-Alloy Steel Strip Based on Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Zengshuai Qiu

    2018-01-01

    Full Text Available Intensive cooling technology is widely utilized in the production of high-strength hot-rolled steel strip. However, intensive cooling at high cooling rate may cause stress heterogeneity on a steel strip, which further generates great residual stress and influences steel strip shape. In this study, a three-dimensional finite element (FE model of high-strength low-alloy steel strip on the run-out table coupled with heat transfer, phase transformation, and strain/stress is developed by ABAQUS software. To enhance modeling precision, several experiments are conducted, such as uniaxial tensile test at multiple temperatures, dynamic continuous cooling transformation, and scanning electron microscopy, to determine the material properties and boundary conditions of the FE model. Four new models are established based on this model to reduce the residual stress of strip by modifying the initial and boundary conditions. Results show that reducing the initial transverse temperature difference is the most effective in reducing residual stress, followed by sparse cooling, edge masking, and posterior cooling.

  14. Development of a colloidal gold immunochromatographic strip based on HSP70 for the rapid detection of Echinococcus granulosus in sheep.

    Science.gov (United States)

    Zhuo, Xunhui; Yu, Yingchao; Chen, Xueqiu; Zhang, Zhuangzhi; Yang, Yi; Du, Aifang

    2017-06-15

    Echinococcus granulosus is the causative pathogen of cystic echinococcosis, a serious disease endangering human and animal health. In this study, an immunochromatographic strip was developed based on the recombinant protein Heat shock protein 70 (HSP70) for the serological detection of E. granulosus. The protocol completes within 20min requiring no specialized equipment or chemical reagents, while specificity tests confirmed no cross-reactivity with positive serum of Fasciola hepatica, Haemonchus contortus, Peste des petits ruminants virus (PPRV) and Foot-and-mouth disease virus (FMDV). The strips remained stable after storage at 4°C for up to 8 months. Both immunochromatographic strip and ELISA tests were applied to detect E. granulosus antibody in a total of 728 serum samples obtained from slaughter houses in Zhejiang Province. Our data revealed positive rates of 2.61 and 1.65% by immunochromatographic strip and ELISA methods, respectively. The immunochromatographic strip test developed in this study provides a simple, specific and rapid method of E. granulosus antibody detection and infected sheep monitoring. Copyright © 2017. Published by Elsevier B.V.

  15. EUV mirror based absolute incident flux detector

    Science.gov (United States)

    Berger, Kurt W.

    2004-03-23

    A device for the in-situ monitoring of EUV radiation flux includes an integrated reflective multilayer stack. This device operates on the principle that a finite amount of in-band EUV radiation is transmitted through the entire multilayer stack. This device offers improvements over existing vacuum photo-detector devices since its calibration does not change with surface contamination.

  16. Design of polarization-insensitive 2 × 2 multimode interference coupler based on double strip silicon nitride waveguides

    Science.gov (United States)

    Yang, Huimin; Zheng, Pengfei; Liu, Panpan; Hu, Guohua; Yun, Binfeng; Cui, Yiping

    2018-03-01

    A polarization-insensitive 2 × 2 multimode interference coupler based on double strip silicon nitride waveguides is proposed and optimized by using the three-dimensional finite difference time domain method. By optimizing the device's structure parameters in detail, polarization independent excess loss of -0.32dB is obtained, and negligible output uniformities of -0.02dB and -0.03dB could be achieved for the TE and TM mode, respectively. The optimized polarization-insensitive 2 × 2 multimode interference coupler could be served as a building block on the double strip silicon nitride waveguides platform.

  17. Analysis of laser jamming to satellite-based detector

    Science.gov (United States)

    Wang, Si-wen; Guo, Li-hong; Guo, Ru-hai

    2009-07-01

    The reconnaissance satellite, communication satellite and navigation satellite used in the military applications have played more and more important role in the advanced technique wars and already become the significant support and aid system for military actions. With the development of all kinds of satellites, anti-satellite laser weapons emerge as the times require. The experiments and analyses of laser disturbing CCD (charge coupled detector) in near ground have been studied by many research groups, but their results are not suitable to the case that using laser disturbs the satellite-based detector. Because the distance between the satellite-based detector and the ground is very large, it is difficult to damage it directly. However the optical receive system of satellite detector has large optical gain, so laser disturbing satellite detector is possible. In order to determine its feasibility, the theoretical analyses and experimental study are carried out in the paper. Firstly, the influence factors of laser disturbing satellite detector are analyzed in detail, which including laser power density on the surface of the detector after long distance transmission, and laser power density threshold for disturbing etc. These factors are not only induced by the satellite orbit, but dependence on the following parameters: laser average power in the ground, laser beam quality, tracing and aiming precision and atmospheric transmission. A calculation model is developed by considering all factors which then the power density entering into the detector can be calculated. Secondly, the laser disturbing experiment is performed by using LD (laser diode) with the wavelength 808 nm disturbing CCD 5 kilometer away, which the disturbing threshold value is obtained as 3.55×10-4mW/cm2 that coincides with other researcher's results. Finally, using the theoretical model, the energy density of laser on the photosensitive surface of MSTI-3 satellite detector is estimated as about 100m

  18. A new kind of metal detector based on chaotic oscillator

    Science.gov (United States)

    Hu, Wenjing

    2017-12-01

    The sensitivity of a metal detector greatly depends on the identification ability to weak signals from the probe. In order to improve the sensitivity of metal detectors, this paper applies the Duffing chaotic oscillator to metal detectors based on its characteristic which is very sensitive to weak periodic signals. To make a suitable Duffing system for detectors, this paper computes two Lyapunov characteristics exponents of the Duffing oscillator, which help to obtain the threshold of the Duffing system in the critical state accurately and give quantitative criteria for chaos. Meanwhile, a corresponding simulation model of the chaotic oscillator is made by the Simulink tool box of Matlab. Simulation results shows that Duffing oscillator is very sensitive to sinusoidal signals in high frequency cases. And experimental results show that the measurable diameter of metal particles is about 1.5mm. It indicates that this new method can feasibly and effectively improve the metal detector sensitivity.

  19. Diffraction measurements with a boron-based GEM neutron detector

    Science.gov (United States)

    Croci, Gabriele; Albani, Giorgia; Cazzaniga, Carlo; Perelli Cippo, Enrico; Schooneveld, Erik; Claps, Gerardo; Cremona, Anna; Grosso, Giovanni; Muraro, Andrea; Murtas, Fabrizio; Rebai, Marica; Scherillo, Antonella; Tardocchi, Marco; Gorini, Giuseppe

    2014-07-01

    The research of reliable substitutes of 3He detectors is an important task for the affordability of new neutron scattering instrumentation for future spallation sources like the European Spallation Source. GEM (Gas Electron Multiplier)-based detectors represent a valid alternative since they can combine high-rate capability, coverage of up to 1\\ \\text{m}^{2} area and good intrinsic spatial resolution (for this detector class it can be better than 0.5 mm). The first neutron diffraction measurements performed using a borated GEM detector are reported. The detector has an active area of 10 \\times 5\\ \\text{cm}^{2} and is equipped with a borated cathode. The GEM detector was read out using the standard ISIS Data Acquisition System. The comparison with measurements performed with standard 3He detectors shows that the broadening of the peaks measured on the diffractogram obtained with the GEM is 20-30% wider than the one obtained by 3He tubes but the active area of the GEM is twice that of 3He tubes. The GEM resolution is improved if half of its active area is considered. The signal-to-background ratio of the GEM is about 1.5 to 2 times lower than that of 3He. This measurement proves that GEM detectors can be used for neutron diffraction measurements and paves the way for their use at future neutron spallation sources.

  20. Polyaniline-based optical ammonia detector

    Science.gov (United States)

    Duan, Yixiang; Jin, Zhe; Su, Yongxuan

    2002-01-01

    Electronic absorption spectroscopy of a polyaniline film deposited on a polyethylene surface by chemical oxidation of aniline monomer at room temperature was used to quantitatively detect ammonia gas. The present optical ammonia gas detector was found to have a response time of less than 15 s, a regeneration time of less than 2 min. at room temperature, and a detection limit of 1 ppm (v/v) for ammonia, with a linear dynamic range from 180 ppm to 18,000 ppm.

  1. Smartphone-Based Dual-Modality Imaging System for Quantitative Detection of Color or Fluorescent Lateral Flow Immunochromatographic Strips.

    Science.gov (United States)

    Hou, Yafei; Wang, Kan; Xiao, Kun; Qin, Weijian; Lu, Wenting; Tao, Wei; Cui, Daxiang

    2017-12-01

    Nowadays, lateral flow immunochromatographic assays are increasingly popular as a diagnostic tool for point-of-care (POC) test based on their simplicity, specificity, and sensitivity. Hence, quantitative detection and pluralistic popular application are urgently needed in medical examination. In this study, a smartphone-based dual-modality imaging system was developed for quantitative detection of color or fluorescent lateral flow test strips, which can be operated anywhere at any time. In this system, the white and ultra-violet (UV) light of optical device was designed, which was tunable with different strips, and the Sobel operator algorithm was used in the software, which could enhance the identification ability to recognize the test area from the background boundary information. Moreover, this technology based on extraction of the components from RGB format (red, green, and blue) of color strips or only red format of the fluorescent strips can obviously improve the high-signal intensity and sensitivity. Fifty samples were used to evaluate the accuracy of this system, and the ideal detection limit was calculated separately from detection of human chorionic gonadotropin (HCG) and carcinoembryonic antigen (CEA). The results indicated that smartphone-controlled dual-modality imaging system could provide various POC diagnoses, which becomes a potential technology for developing the next-generation of portable system in the near future.

  2. Smartphone-Based Dual-Modality Imaging System for Quantitative Detection of Color or Fluorescent Lateral Flow Immunochromatographic Strips

    Science.gov (United States)

    Hou, Yafei; Wang, Kan; Xiao, Kun; Qin, Weijian; Lu, Wenting; Tao, Wei; Cui, Daxiang

    2017-04-01

    Nowadays, lateral flow immunochromatographic assays are increasingly popular as a diagnostic tool for point-of-care (POC) test based on their simplicity, specificity, and sensitivity. Hence, quantitative detection and pluralistic popular application are urgently needed in medical examination. In this study, a smartphone-based dual-modality imaging system was developed for quantitative detection of color or fluorescent lateral flow test strips, which can be operated anywhere at any time. In this system, the white and ultra-violet (UV) light of optical device was designed, which was tunable with different strips, and the Sobel operator algorithm was used in the software, which could enhance the identification ability to recognize the test area from the background boundary information. Moreover, this technology based on extraction of the components from RGB format (red, green, and blue) of color strips or only red format of the fluorescent strips can obviously improve the high-signal intensity and sensitivity. Fifty samples were used to evaluate the accuracy of this system, and the ideal detection limit was calculated separately from detection of human chorionic gonadotropin (HCG) and carcinoembryonic antigen (CEA). The results indicated that smartphone-controlled dual-modality imaging system could provide various POC diagnoses, which becomes a potential technology for developing the next-generation of portable system in the near future.

  3. Design,construction and commissioning of a cylinder of double-sided silicon micro-strips detectors for the Star experiment at RHIC; Developpement et mise en oeuvre de detecteurs silicium a micropistes pour l'experience star

    Energy Technology Data Exchange (ETDEWEB)

    Guedon, M

    2005-05-15

    This study has been performed in the frame of quark gluon plasma physics research in the STAR experiment at RHIC. It deals with the design, the construction and the commissioning of a barrel of silicon-strip detectors (SSD). Added to the Silicon Vertex Tracker (SVT) of the STAR detector, it extends the capabilities of track reconstruction for charged particles emitted in ultra-relativistic heavy-ion collisions. It also contributes to the general study of the quark-gluon plasma production undertaken at STAR. The SSD is a cylinder of 1 m long and of 23 cm radius, and it is composed of 320 compact identical modules. Each module includes one double-sided silicon micro-strip detector, 12 readout chips ALICE 128C, 12 TAB ribbons, 2 COSTAR control chips and 2 hybrids supporting all the components. The document explains why the SSD is an important and relevant element, and justifies the technological choices as well as their validation by in-beam characterization. All component functionalities, characteristics and test procedures are presented. The data and test results are stored in a database for tracing purpose. Component and module production is described. Two parallel studies have been performed, analysed and described. One on the temperature dependence of the module performances and the other one on the optimal adjustments of the analogue blocks inside the ALICE 128C chip. The SSD installation on the RHIC site as well as the commissioning are presented together with the first data takings. (author)

  4. Design of the flame detector based on pyroelectric infrared sensor

    Science.gov (United States)

    Liu, Yang; Yu, Benhua; Dong, Lei; Li, Kai

    2017-10-01

    As a fire detection device, flame detector has the advantages of short reaction time and long distance. Based on pyroelectric infrared sensor working principle, the passive pyroelectric infrared alarm system is designed, which is mainly used for safety of tunnel to detect whether fire occurred or not. Modelling and Simulation of the pyroelectric Detector Using Labview. An attempt was made to obtain a simple test platform of a pyroelectric detector which would make an excellent basis for the analysis of its dynamic behaviour. After many experiments, This system has sensitive response, high anti-interference ability and safe and reliable performance.

  5. Alpha-particle detection based on the BJT detector and simple, IC-based readout electronics

    Energy Technology Data Exchange (ETDEWEB)

    Rovati, L; Bonaiuti, M [Dipartimento di Ingegneria dell' Informazione, Universita di Modena e Reggio Emilia, Modena (Italy); Bettarini, S [Dipartimento di Fisica, Universita di Pisa and INFN Pisa, Pisa (Italy); Bosisio, L [Dipartimento di Fisica, Universita di Trieste and INFN Trieste, Trieste (Italy); Dalla Betta, G-F; Tyzhnevyi, V [Dipartimento di Ingegneria e Scienza dell' Informazione, Universita di Trento e INFN Trento, Trento (Italy); Verzellesi, G [Dipartimento di Scienze e Metodi dell' Ingegneria, Universita di Modena e Reggio Emilia and INFN Trento, Reggio Emilia (Italy); Zorzi, N, E-mail: giovanni.verzellesi@unimore.i [Fondazione Bruno Kessler (FBK), Trento (Italy)

    2009-11-15

    In this paper we propose a portable instrument for alpha-particle detection based on a previously-developed BJT detector and a simple, IC-based readout electronics. Experimental tests of the BJT detector and readout electronics are reported. Numerical simulations are adopted to predict the performance enhancement achievable with optimized BJT detectors.

  6. Alpha-particle detection based on the BJT detector and simple, IC-based readout electronics

    International Nuclear Information System (INIS)

    Rovati, L; Bonaiuti, M; Bettarini, S; Bosisio, L; Dalla Betta, G-F; Tyzhnevyi, V; Verzellesi, G; Zorzi, N

    2009-01-01

    In this paper we propose a portable instrument for alpha-particle detection based on a previously-developed BJT detector and a simple, IC-based readout electronics. Experimental tests of the BJT detector and readout electronics are reported. Numerical simulations are adopted to predict the performance enhancement achievable with optimized BJT detectors.

  7. Membrane-based lateral flow immunochromatographic strip with nanoparticles as reporters for detection: A review.

    Science.gov (United States)

    Huang, Xiaolin; Aguilar, Zoraida P; Xu, Hengyi; Lai, Weihua; Xiong, Yonghua

    2016-01-15

    Membrane-based lateral flow immunochromatographic strip (LFICS) is widely used in various fields because of its simplicity, rapidity (detection within 10min), and low cost. However, early designs of membrane-based LFICS for preliminary screening only provide qualitative ("yes/no" signal) or semi-quantitative results without quantitative information. These designs often suffer from low-signal intensity and poor sensitivity and are only capable of single analyte detection, not simultaneous multiple detections. The performance of existing techniques used for detection using LFICS has been considerably improved by incorporating different kinds of nanoparticles (NPs) as reporters. NPs can serve as alternative labels and improve analytical sensitivity or limit of detection of LFICS because of their unique properties, such as optical absorption, fluorescence spectra, and magnetic properties. The controlled manipulation of NPs allows simultaneous or multiple detections by using membrane-based LFICS. In this review, we discuss how colored (e.g., colloidal gold, carbon, and colloidal selenium NPs), luminescent (e.g., quantum dots, up-converting phosphor NPs, and dye-doped NPs), and magnetic NPs are integrated into membrane-based LFICS for the detection of target analytes. Gold NPs are also featured because of their wide applications. Different types and unique properties of NPs are briefly explained. This review focuses on examples of NP-based LFICS to illustrate novel concepts in various devices with potential applications as screening tools. This review also highlights the superiority of NP-based approaches over existing conventional strategies for clinical analysis, food safety, and environmental monitoring. This paper is concluded by a short section on future research trends regarding NP-based LFICS. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Scintillation Particle Detectors Based on Plastic Optical Fibres and Microfluidics

    CERN Document Server

    Mapelli, Alessandro; Renaud, Philippe

    2011-01-01

    This thesis presents the design, development, and experimental validation of two types of scintillation particle detectors with high spatial resolution. The first one is based on the well established scintillating fibre technology. It will complement the ATLAS (A Toroidal Large ApparatuS) detector at the CERN Large Hadron Collider (LHC). The second detector consists in a microfabricated device used to demonstrate the principle of operation of a novel type of scintillation detector based on microfluidics. The first part of the thesis presents the work performed on a scintillating fibre tracking system for the ATLAS experiment. It will measure the trajectory of protons elastically scattered at very small angles to determine the absolute luminosity of the CERN LHC collider at the ATLAS interaction point. The luminosity of an accelerator characterizes its performance. It is a process-independent parameter that is completely determined by the properties of the colliding beams and it relates the cross section of a ...

  9. Robust Grape Detector Based on SVMs and HOG Features

    Directory of Open Access Journals (Sweden)

    Pavel Škrabánek

    2017-01-01

    Full Text Available Detection of grapes in real-life images is a serious task solved by researchers dealing with precision viticulture. In the case of white wine varieties, grape detectors based on SVMs classifiers, in combination with a HOG descriptor, have proven to be very efficient. Simplified versions of the detectors seem to be the best solution for practical applications. They offer the best known performance versus time-complexity ratio. As our research showed, a conversion of RGB images to grayscale format, which is implemented at an image preprocessing level, is ideal means for further improvement of performance of the detectors. In order to enhance the ratio, we explored relevance of the conversion in a context of a detector potential sensitivity to a rotation of berries. For this purpose, we proposed a modification of the conversion, and we designed an appropriate method for a tuning of such modified detectors. To evaluate the effect of the new parameter space on their performance, we developed a specialized visualization method. In order to provide accurate results, we formed new datasets for both tuning and evaluation of the detectors. Our effort resulted in a robust grape detector which is less sensitive to image distortion.

  10. Colloidal Gold Probe-Based Immunochromatographic Strip Assay for the Rapid Detection of Microbial Transglutaminase in Frozen Surimi

    Directory of Open Access Journals (Sweden)

    Daming Fan

    2016-01-01

    Full Text Available Adding microbial transglutaminase (MTGase to frozen surimi to enable the surimi to be sold as a higher-grade product at a higher price defrauds surimi product manufacturers and undercuts legitimate industry prices. Therefore, it is important to develop an accurate method of detecting the presence of MTGase in surimi. In this study, an immunochromatographic strip assay with a colloidal gold antibody probe was successfully developed and used to rapidly and qualitatively detect MTGase in surimi samples. The results were obtained in less than 10 min. The limit for the qualitative detection of MTGase using the immunochromatographic strip assay was identified as 1.0 μg/mL. The results of the immunochromatographic strip analysis of frozen surimi samples were verified by comparison with the results of a sandwich enzyme-linked immunosorbent assay. The colloidal gold probe-based immunochromatographic strip assay was thus found to be a rapid, economical, and user friendly method of detecting MTGase in surimi.

  11. Ultrasensitive Immunochromatographic Strip for Fast Screening of 27 Sulfonamides in Honey and Pork Liver Samples Based on a Monoclonal Antibody.

    Science.gov (United States)

    Chen, Yanni; Guo, Lingling; Liu, Liqiang; Song, Shanshan; Kuang, Hua; Xu, Chuanlai

    2017-09-20

    Group-specific monoclonal antibodies (Mabs) with selectivity for 27 sulfonamides were developed based on new combinations of immunogen and coating antigen. The Mab was able to recognize 27 sulfonamides with 50% inhibition concentration (IC 50 ) values ranging from 0.15 to 15.38 μg/L. In particular, the IC 50 values for five sulfonamides (sulfamethazine, sulfaquinoxaline, sulfamonomethoxine, sulfadimethoxine, and sulfamethoxazole) were 0.51, 0.15, 0.56, 0.54, and 2.14 μg/L, respectively. On the basis of the Mab, an immunochromatographic lateral flow strip test was established for rapid screening of sulfonamides in honey samples. The visual limit of detection of the strip test for most sulfonamides in spiked honey samples was below 10 μg/kg, satisfying the requirements of authorities. Positive honey and pork liver samples, which had been confirmed by high-performance liquid chromatography/mass spectrometry, were used to validate the reliability of the proposed strip test. The immunochromatographic lateral flow strip test provides a rapid and convenient method for fast screening of sulfonamides in honey samples.

  12. Tandem strip mill's multi-parameter coupling dynamic modeling based on the thickness control

    Science.gov (United States)

    Peng, Yan; Zhang, Yang; Sun, Jianliang; Zang, Yong

    2015-03-01

    The rolling process is determined by the interaction of a number of different movements, during which the relative movement occurs between the vibrating roll system and the rolled piece, and the roll system's vibration interacts with the strip's deformation and rigid movement. So many parameters being involved leads to a complex mechanism of this coupling effect. Through testing and analyzing the vibration signals of the mill in the rolling process, the rolling mill's coupled model is established with comprehensive consideration of the coupling interaction between the mill's vertical vibration, its torsional vibration and the working roll's horizontal vibration, and vibration characteristics of different forms of rolling mill's vibration are analyzed under the coupling effect. With comprehensive attention to the relationship between the roll system, the moving strip and the rolling parameters' dynamic properties, and also from the strip thickness control point of view, further research is done on the coupling mechanism between the roll system's movement and the moving strip's characteristics in the rolling process. As a result, the law of inertial coupling and the stiffness coupling effect caused by different forms of the roll system's vibration is determined and the existence of nonlinear characteristics caused by the elastic deformation of moving strip is also found. Furthermore, a multi-parameter coupling-dynamic model is established which takes the tandem strip mill as its research object by making a detailed kinematics analysis of the roll system and using the principle of virtual work. The coupling-dynamic model proposes the instruction to describe the roll system's movement, and analyzes its dynamic response and working stability, and provides a theoretical basis for the realization of the strip thickness' dynamic control.

  13. Central Tracking Detector Based on Scintillating Fibres

    CERN Multimedia

    2002-01-01

    Scintillating fibres form a reasonable compromise for central tracking detectors in terms of price, resolution, response time, occupancy and heat production. \\\\ \\\\ New fluorescents with large Stokes shifts have been produced, capable of working without wavelength shifters. Coherent multibundles have been developed to achieve high packing fractions. Small segments of tracker shell have been assembled and beam tests have confirmed expectations on spatial resolution. An opto-electronic delay line has been designed to delay the track patterns and enable coincidences with a first level trigger. Replacement of the conventional phosphor screen anode with a Si pixel chip is achieved. This tube is called ISPA-tube and has already been operated in beam tests with a scintillating fibres tracker. \\\\ \\\\ The aim of the proposal is to improve hit densities for small diameter fibres by increasing the fraction of trapped light, by reducing absorption and reflection losses, by reflecting light at the free fibre end, and by inc...

  14. Development of computer based ultrasonic flaw detector for nondestructive testing

    International Nuclear Information System (INIS)

    Lee, Weon Heum; Kim, Jin Koo; Kim, Yang Rae; Choi, Kwan Sun; Kim, Sun Hyung; Lee, Sun Heum

    1996-01-01

    Ultrasonic Testing is one of the most widely used method of Nondestructive testing for Pre-Service Inspection(PSI) and In-Service Inspection(ISI) in the structure of Bridges, Power plants, chemical plants and heavy industrial fields. It is very important target to estimate safety, remain life, Quality Control of the Structure. Also, a lot of research for quantities evaluation and analysis inspection data is proceeding. But traditional portable ultrasonic flaw detector had been following disadvantages. 1) Analog ultrasonic flaw detector decreased credibility of ultrasonic test, because it is impossible for saying data and digital signal processing. 2) Stand-alone digital ultrasonic flaw detector cannot effectively evaluate received signals because of lack of its storage memory. To overcome this shortcoming, we develop the computer based ultrasonic flaw detector for nondestructive testing. It can store the received signal and effectively evaluate the signal, and then enhance the reliability of the testing results.

  15. Development of X-ray detector based on phototransistor

    International Nuclear Information System (INIS)

    Ramacos Fardela; Kusminarto

    2014-01-01

    X-ray interaction with matter can produce phenomenon of fluorescence that emits visible light. This phenomenon has been exploited to design an X-ray detector based on photo transistor by attaching a screen ZnS(Ag) on the surface of the photo transistor which is arranged in a Darlington circuit. Response of detector was done by collimating of X-rays beam from the X-ray generator tube Philips 2000 watts, 60 kV type PW 2215/20 NR 780 026 and measure the detector output voltage (V out ). Varying the current by 5, 10, 15, 20, 25, 30, 35 and 40 mA in the X-ray panel. The experimental results showed that the Darlington circuit can be applied to design the detector of X-ray based on phototransistor. The results show that there is a linear relationship between the change in the intensity of X-ray detectors with voltage output phototransistor when it was closed with fluorescence materials ZnS(Ag), the linearity coefficient was R 2 = 0.99. Sensitivity of detector was obtained to be 3.7 x 10 -2 mV per cpm. (author)

  16. NEW LENSLET BASED IFS WITH HIGH DETECTOR PIXEL EFFICIENCY

    Science.gov (United States)

    Gong, Qian

    2018-01-01

    Three IFS types currently used for optical design are: lenslet array, imager slicer, and lenslet array and fiber combined. Lenslet array based Integral Field Spectroscopy (IFS) is very popular for many astrophysics applications due to its compactness, simplicity, as well as cost and mass savings. The disadvantage of lenslet based IFS is its low detector pixel efficiency. Enough spacing is needed between adjacent spectral traces in cross dispersion direction to avoid wavelength cross-talk, because the same wavelength is not aligned to the same column on detector. Such as on a recent exoplanet coronagraph instrument study to support the coming astrophysics decadal survey (LUVOIR), to cover a 45 λ/D Field of View (FOV) with a spectral resolving power of 200 at shortest wavelength, a 4k x 4k detector array is needed. This large format EMCCD pushes the detector into technology development area with a low TRL. Besides the future mission, it will help WFIRST coronagraph IFS by packing all spectra into a smaller area on detector, which will reduce the chance for electrons to be trapped in pixels, and slow the detector degradation during the mission.The innovation we propose here is to increase the detector packing efficiency by grouping a number of lenslets together to form many mini slits. In other words, a number of spots (Point Spread Function at lenslet focus) are aligned into a line to resemble a mini slit. Therefore, wavelength cross-talk is no longer a concern anymore. This combines the advantage of lenslet array and imager slicer together. The isolation rows between spectral traces in cross dispersion direction can be reduced or removed. So the packing efficiency is greatly increased. Furthermore, the today’s microlithography and etching technique is capable of making such a lenslet array, which will relax the detector demand significantly. It will finally contribute to the habitable exoplanets study to analyzing their spectra from direct images. Detailed theory

  17. WE-DE-207B-01: Optimization for Contrast-Enhanced Spectral Mammography Based On Photon-Counting Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ding, H; Molloi, S [University of California, Irvine, CA (United States)

    2016-06-15

    Purpose: To investigate the feasibility of optimizing the imaging parameters for contrast-enhanced spectral mammography based on Si strip photon-counting detectors. Methods: A computer simulation model using polyenergetic spectra from a tungsten anode x-ray tube and a Si-based photon-counting detector was evaluated for contrast-enhanced spectral mammography. The simulation traces the emission of photons from the x-ray source, attenuation through the breast and subsequent absorption in the detector. The breast was modeled as a mixture of adipose and mammary gland tissues with a breast density of 30%. A 4 mm iodine signal with a concentration of 4 mg/ml was used to simulate the enhancement of a lesion. Quantum efficiency of the detector was calculated based on the effective attenuation length in the Si strips. The figure-of-merit (FOM), which was defined as the decomposed iodine signal-to-noise ratio (SNR) with respect to the square root of the mean glandular dose (MGD), was chosen to optimize the imaging parameters, in terms of beam energy, splitting energy, and pre-filtrations for breast of various thicknesses and densities. Results: The optimal imaging parameters, which lead to the highest FOM, were found at a beam energy of 45 kVp with a splitting energy at 34 keV for an averaged breast thickness of 4 cm with a standard 0.75 mm Al pre-filtration. The optimal tube voltage varied slightly from 46 to 44 kVp as the breast thickness increases from 2 to 8 cm. The optimal tube voltage decreased to 42 kVp when the Al pre-filtration was increased to 3 mm. Conclusion: This simulation study predicted the optimal imaging parameters for application of photon-counting spectral mammography to contrast-enhanced imaging. The simulation results laid the ground work for future phantom and clinical studies. Grant funding from Philips Medical Systems.

  18. Rapid, quantitative and sensitive immunochromatographic assay based on stripping voltammetric detection of a metal ion label

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Fang; Wang, Kaihua; Lin, Yuehe

    2005-10-10

    A novel, sensitive immunochromatographic electrochemical biosensor (IEB) which combines an immunochromatographic strip technique with an electrochemical detection technique is demonstrated. The IEB takes advantages of the speed and low-cost of the conventional immunochromatographic test kits and high-sensitivity of stripping voltammetry. Bismuth ions (Bi3+) have been coupled with the antibody through the bifunctional chelating agent diethylenetriamine pentaacetic acid (DTPA). After immunoreactions, Bi3+ was released and quantified by anodic stripping voltammetry at a built-in single-use screen-printed electrode. As an example for the applications of such novel device, the detection of human chorionic gonadotronphin (HCG) in a specimen was performed. This biosensor provides a more user-friendly, rapid, clinically accurate, and less expensive immunoassay for such analysis in specimens than currently available test kits.

  19. Construction of two large-size four-plane micromegas detectors

    CERN Document Server

    Bianco, Michele; Degrange, Jordan; De Oliveira, Rui; Düdder, Andreas; Farina, Edoardo; Kuger, Fabian; Iengo, Paolo; Gomez, Francisco Perez; Lin, Tai-Hua; Schott, Matthias; Sekhniaidze, Givi; Sforza, Federico; Sidiropoulou, Ourania; Valderanis, Chrysostomos; Vergain, Maurice; Wotschack, Jörg

    2016-01-01

    We report on the construction and initial performance studies of two micromegas detector quadruplets with an area of 0.5 m$^2$. They serve as prototypes for the planned upgrade project of the ATLAS muon system. Their design is based on the resistive-strip technology and thus renders the detectors spark tolerant. Each quadruplet comprises four detection layers with 1024 readout strips and a strip pitch of 415 $\\mu$m. In two out of the four layers the strips are inclined by $\\pm$1.5$^{\\circ}$ to allow for the measurement of a second coordinate. We present the detector concept and report on the experience gained during the detector construction. In addition an evaluation of the detector performance with cosmic rays and test-beam data is given.

  20. Development of a neutron imager based on superconducting detectors

    Energy Technology Data Exchange (ETDEWEB)

    Miyajima, Shigeyuki, E-mail: miyajima@nict.go.jp [Department of Physics and Engineering, Osaka Prefecture University (Japan); Institute for Nanofabrication Research, Osaka Prefecture University (Japan); Yamaguchi, Hiroyuki; Nakayama, Hirotaka; Shishido, Hiroaki [Department of Physics and Engineering, Osaka Prefecture University (Japan); Institute for Nanofabrication Research, Osaka Prefecture University (Japan); Fujimaki, Akira [Department of Quantum Engineering, Nagoya University (Japan); Hidaka, Mutsuo [National Institute of Advanced Industrial Science and Technology (Japan); Harada, Masahide; Oikawa, Kenichi; Oku, Takayuki; Arai, Masatoshi [J-PARC Center, Japan Atomic Energy Agency (Japan); Ishida, Takekazu [Department of Physics and Engineering, Osaka Prefecture University (Japan); Institute for Nanofabrication Research, Osaka Prefecture University (Japan)

    2016-11-15

    Highlights: • A neutron detector based on superconducting meander line is demonstrated. • Fast response time of a few tens ns is obtained. • Spatial resolution is 1 μm and can be improved to sub-μm scale. • The proposed neutron detector can operate under the γ-ray fields. - Abstract: We succeeded in demonstrating a neutron detector based on a Nb superconducting meander line with a {sup 10}B conversion layer for a neutron imager based on superconductor devices. We use a current-biased kinetic inductance detector (CB-KID), which is composed of a meander line, for detection of a neutron with high spatial resolution and fast response time. The thickness of Nb meander lines is 40 nm and the line width is narrower than 3 mu m. The area of 8 mm × 8 mm is covered by CB-KIDs, which are assembled at the center of the Si chip of the size 22 mm × 22 mm. The Nb CB-KIDs with a {sup 10}B conversion layer output the voltage by irradiating pulsed neutrons. We have investigated γ/n discrimination of a Nb-based CB-KID with {sup 10}B conversion layer using a Cd plate, which indicates that a CB-KID can operate as a neutron detector under the strong γ-ray fields.

  1. Enhanced sensitivity of laterl flow strip biosensors based on enyzmatic reaction and nanomaterials

    Science.gov (United States)

    Xu, Hui

    Ultrasensitive detection for trace amount of proteins plays pivotal role in the diagnosis of specific diseases in clinical application, basic discovery research and the improvement of proteomics. Recently, lateral flow strip biosensor (LFSB) has gained considerable attention for protein analysis. Compared with the traditional immunoassays, LFSB has several advantages: user-friendly format, short assay time (generally several minutes), less interference due to chromatographic separation, a relatively low cost, and no requirements for skilled technicians. This ideal technique is suitable for on-site testing by people who are untrained. Traditional gold nanoparticles (GNPs) based LFSB have been used for qualitative and semiquantitative analysis, the application of GNP-based LFSB is limited by its low sensitivity. In this dissertation, different nanomaterials and advanced detection technologies have been used to enhance the LFSB sensitivities. An ultrasensitive LFSB based on horseradish peroxidase (HRP)/GNP dual labels was developed for qualitative (Yes/No) and quantitative detection of protein. The LFSB signal was enhanced dramatically by introducing the second tracer (enzyme) on the GNP surface. The detection limit of LFSB was 100 times lower than that of GNP-based LFSB. A fluorescent LFSB based on enzyme tracers was developed for sensitive detection of proteins. Alkaline Phosphatase (ALP) was selected as a label to prepare the LFSB. The signal was from the fluorescent emission of the ELF-97 alcohol precipitate which was the product of ALP catalyzed dephosphorylation of ELF-97 phosphate. ALP-conjugated antibody (ALP-Ab) functionalized gold nanoparticles (GNPs) were used as labels for the development of a chemiluminescence-based quantitative LFSB. The use of chemiluminescence detection and GNPs as enzyme carriers allowed accurate and sensitive analyte detection. GNP-decorated silica nanorods (GNP-SiNRs) were synthesized and employed as the labels for ultrasensitive

  2. Selective determination of trace copper(II) by cathodic adsorptive stripping voltammetry with a naphthol-derivative Schiff's base.

    Science.gov (United States)

    Shamsipur, Mojtaba; Saeidi, Mahboubeh; Sharghi, Hashem; Naeimi, Hossein

    2003-01-01

    A selective and sensitive stripping voltammetric method for the determination of trace amounts of copper(II) with a recently synthesized naphthol-derivative Schiff's base (2,2'-[1,2-ethanediylbis(nitriloethylidyne)]bis(1-naphthalene)) is presented. The method is based on adsorptive accumulation of the resulting copper-Schiff's base complex on a hanging mercury drop electrode, followed by the stripping voltammetric measurement at the reduction current of adsorbed complex at -0.15 V (vs. Ag/AgCl). The optimal conditions for the stripping analysis of copper include pH 5.5 to 6.5, 8 microM Schiff's base and an accumulation potential of -0.05 V (vs. Ag/AgCI). The peak current is linearly proportional to the copper concentration over a range 2.3-50.8 ng ml(-1) with a limit of detection of 1.9 ng ml(-1). The accumulation time and RSD are 90 s and (3.2-3.5)%, respectively. The method was applied to the determination of copper in some analytical grade salts, tap water, human serum and sheep's liver.

  3. Instrumentation for Kinetic-Inductance-Detector-Based Submillimeter Radio Astronomy

    Science.gov (United States)

    Duan, Ran

    A substantial amount of important scientific information is contained within astronomical data at the submillimeter and far-infrared (FIR) wavelengths, including information regarding dusty galaxies, galaxy clusters, and star-forming regions; however, these wavelengths are among the least-explored fields in astronomy because of the technological difficulties involved in such research. Over the past 20 years, considerable efforts have been devoted to developing submillimeter- and millimeter-wavelength astronomical instruments and telescopes. The number of detectors is an important property of such instruments and is the subject of the current study. Future telescopes will require as many as hundreds of thousands of detectors to meet the necessary requirements in terms of the field of view, scan speed, and resolution. A large pixel count is one benefit of the development of multiplexable detectors that use kinetic inductance detector (KID) technology. This dissertation presents the development of a KID-based instrument including a portion of the millimeter-wave bandpass filters and all aspects of the readout electronics, which together enabled one of the largest detector counts achieved to date in submillimeter-/millimeter-wavelength imaging arrays: a total of 2304 detectors. The work presented in this dissertation has been implemented in the MUltiwavelength Submillimeter Inductance Camera (MUSIC), a new instrument for the Caltech Submillimeter Observatory (CSO).

  4. ATLAS Strip Upgrade

    CERN Document Server

    Bernabeu, J; The ATLAS collaboration

    2012-01-01

    A phased upgrade of the Large Hadron Collider (LHC) at CERN is planned. The last upgrade phase (HL-LHC) is currently foreseen in 2022-2023. It aims to increase the integrated luminosity to about ten times the original LHC design luminosity. To cope with the harsh conditions in terms of particle rates and radiation dose expected during HL-LHC operation, the ATLAS collaboration is developing technologies for a complete tracker replacement. This new detector will need to provide extreme radiation hardness and a high granularity, within the tight constraints imposed by the existing detectors and their services. An all-silicon high-granularity tracking detector is proposed. An international R&D collaboration is working on the strip layers for this new tracker. A number of large area prototype planar detectors produced on p-type wafers have been designed and fabricated for use at HL-LHC. These prototype detectors and miniature test detectors have been irradiated to a set of fluences matched to HL-LHC expectatio...

  5. Cellular automaton-based position sensitive detector equalization

    International Nuclear Information System (INIS)

    Ferrando, Nestor; Herrero, V.; Cerda, J.; Lerche, C.W.; Colom, R.J.; Gadea, R.; Martinez, J.D.; Monzo, J.M.; Mateo, F.; Sebastia, A.; Benlloch, J.M.

    2009-01-01

    Indirect position detectors based on scintillator crystals lack of spacial uniformity in their response. This happens due to crystal inhomogeneities and gain differences among the photomultiplier anodes. In order to solve this, PESIC, an integrated front-end for multianode photomultiplier based nuclear imaging devices was created. One of its main features is the digitally programmable gain adjustment for every photomultiplier output. On another front, cellular automata have been proved to be a useful method for dynamic system modeling. In this paper, a cellular automaton which emulates the behavior of the scintillator crystal, the photomultiplier and the front-end is introduced. Thanks to this model, an automatic energy-based calibration of the detector can be done by configuring the cellular automaton with experimental data and making it evolve up to an stable state. This can be useful as a precalibration method of the detector.

  6. SPECT detector system design based on embedded system

    International Nuclear Information System (INIS)

    Zhang Weizheng; Zhao Shujun; Zhang Lei; Sun Yuanling

    2007-01-01

    A single-photon emission computed tomography detector system based on embedded Linux designed. This system is composed of detector module, data acquisition module, ARM MPU module, network interface communication module and human machine interface module. Its software uses multithreading technology based on embedded Linux. It can achieve high speed data acquisition, real-time data correction and network data communication. It can accelerate the data acquisition and decrease the dead time. The accuracy and the stability of the system can be improved. (authors)

  7. Silicon-Based Detectors at the HL-LHC

    CERN Document Server

    Hartmann, Frank

    2018-01-01

    This document discusses the silicon-based detectors planned for the High Luminosity LHC. The special aspects to cope with the new environment and its challenges, e.g. very high radiation levels and very high instantaneous luminosity thus high pile-up, high occupancy and high data rates, are addressed. The different design choices of the detectors are put into perspective. Exciting topics like trackers, high granularity silicon-based calorimetry with novel 8~inch processing, fast timing and new triggers are described.

  8. Thermal neutron detectors based on hexagonal boron nitride epilayers

    Science.gov (United States)

    Doan, T. C.; Marty, A.; Li, J.; Lin, J. Y.; Jiang, H. X.

    2016-09-01

    Solid-state neutron detectors with high performances are urgently sought after for the detection of fissile materials. Until now, direct-conversion neutron detectors based on semiconductors with a measureable efficiency have not been realized. We have successfully synthesized hexagonal boron nitride (h-BN) epilayers with varying thicknesses (0.3 μm - 50 μm) by metal organic chemical vapor deposition (MOCVD) on sapphire substrates. In this paper, we present the detailed characterization of thermal neutron detectors fabricated from h-BN epilayers with a thickness up to 5 m to obtain insights into the h-BN epilayer thickness dependence of the device performance. The results revealed that the charge collection efficiency is almost independent of the h-BN epilayer thickness. By minimizing h-BN material removal by dry etching, it was shown that detectors incorporating an isotopically 10B-enriched h-BN epilayer of 2.7 μm in thickness exhibited an overall detection efficiency for thermal neutrons of 4% and a charge collection efficiency as high as 83%. By doing away altogether with dry etching, we have successfully realized a simple vertical 43 μm thick h-10BN detector which delivers a detection efficiency of 51.4% for thermal neutrons, which is the highest reported efficiency for any semiconductor-based neutron detector The h-BN detectors possess all the advantages of semiconductor devices including low cost, high efficiency and sensitivity, wafer-scale processing, compact size, light weight, and ability to integrate with other functional devices.

  9. Paper Strip-based Fluorometric Determination of Cyanide with an Internal Reference

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Nam; Hong, Jong-In [Seoul National University, Seoul (Korea, Republic of); Seo, Hyejin; Shin, Ik-Soo [Soongsil University, Seoul (Korea, Republic of)

    2016-08-15

    The rapid, selective, and sensitive determination of cyanide anion (CN{sup -}) using a simple paper strip is highly attractive because cyanide is acutely lethal to living organisms via all routes of administration, including alcohol consumption and inhaling cigarette smoke. Here, a synthetic probe (1) was designed for the selective determination of cyanide. The probe displays rapid and large blue spectral change (Δλ{sub abs}=148 nm, Δλ{sub em}= 165 nm) with respect to target recognition. Probe 1 exhibits a strong push-pull electronic effect and comprises a dimethylaminoaryl group as a donor and malononitrile as an acceptor; the π-conjugation system can be destroyed by the Michael-type addition of cyanide at the electrophilic β-positions of the nitrile groups, resulting in the marked emergence of a peak at λ{sub em}= 515 nm. The developed probe was successfully applied to a paper test strip because of its noticeable optical changes upon reaction with cyanide. The fabricated dumbbell-shaped paper strip with an internal reference allowed the cyanide detection, which is indispensable for quantitative analysis in point-of-care testing. The paper strip test showed selective response to cyanide, with a linear correlation in the range of 0-25 mM in a simple and cost-effective manner.

  10. Range gated strip proximity sensor

    Science.gov (United States)

    McEwan, T.E.

    1996-12-03

    A range gated strip proximity sensor uses one set of sensor electronics and a distributed antenna or strip which extends along the perimeter to be sensed. A micro-power RF transmitter is coupled to the first end of the strip and transmits a sequence of RF pulses on the strip to produce a sensor field along the strip. A receiver is coupled to the second end of the strip, and generates a field reference signal in response to the sequence of pulse on the line combined with received electromagnetic energy from reflections in the field. The sensor signals comprise pulses of radio frequency signals having a duration of less than 10 nanoseconds, and a pulse repetition rate on the order of 1 to 10 MegaHertz or less. The duration of the radio frequency pulses is adjusted to control the range of the sensor. An RF detector feeds a filter capacitor in response to received pulses on the strip line to produce a field reference signal representing the average amplitude of the received pulses. When a received pulse is mixed with a received echo, the mixing causes a fluctuation in the amplitude of the field reference signal, providing a range-limited Doppler type signature of a field disturbance. 6 figs.

  11. Colloidal gold-based immunochromatographic strip assay for the rapid detection of three natural estrogens in milk.

    Science.gov (United States)

    Wang, Zhongxing; Guo, Lingling; Liu, Liqiang; Kuang, Hua; Xu, Chuanlai

    2018-09-01

    In this study, we developed highly sensitive and specific monoclonal antibodies (mAbs) against estrone (E 1 ), 17β-estradiol (17β-E 2 ), and estriol (E 3 ). The half-maximal inhibitory concentration values of anti-E 1 , anti-17β-E 2 , and anti-E 3 mAbs were 0.46, 0.36, and 0.39 ng/mL, respectively, based on competitive enzyme-linked immunosorbent assay (ic-ELISA) results. A rapid colloidal gold-based immunoassay strip assay was developed for the determination of E 1, 17β-E 2 , and E 3 residues in milk samples. The assay had a visual cut-off value of 5 ng/mL, and required 10 min to assess with the naked eye. The results obtained from the immunochromatographic strip assay were consistent with those obtained from ic-ELISA and gas chromatography-mass spectrometry. The immunochromatographic strip assay is useful and rapid for the detection of E 1 , 17β-E 2 , and E 3 in milk. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Radiation imaging with optically read out GEM-based detectors

    Science.gov (United States)

    Brunbauer, F. M.; Lupberger, M.; Oliveri, E.; Resnati, F.; Ropelewski, L.; Streli, C.; Thuiner, P.; van Stenis, M.

    2018-02-01

    Modern imaging sensors allow for high granularity optical readout of radiation detectors such as MicroPattern Gaseous Detectors (MPGDs). Taking advantage of the high signal amplification factors achievable by MPGD technologies such as Gaseous Electron Multipliers (GEMs), highly sensitive detectors can be realised and employing gas mixtures with strong scintillation yield in the visible wavelength regime, optical readout of such detectors can provide high-resolution event representations. Applications from X-ray imaging to fluoroscopy and tomography profit from the good spatial resolution of optical readout and the possibility to obtain images without the need for extensive reconstruction. Sensitivity to low-energy X-rays and energy resolution permit energy resolved imaging and material distinction in X-ray fluorescence measurements. Additionally, the low material budget of gaseous detectors and the possibility to couple scintillation light to imaging sensors via fibres or mirrors makes optically read out GEMs an ideal candidate for beam monitoring detectors in high energy physics as well as radiotherapy. We present applications and achievements of optically read out GEM-based detectors including high spatial resolution imaging and X-ray fluorescence measurements as an alternative readout approach for MPGDs. A detector concept for low intensity applications such as X-ray crystallography, which maximises detection efficiency with a thick conversion region but mitigates parallax-induced broadening is presented and beam monitoring capabilities of optical readout are explored. Augmenting high resolution 2D projections of particle tracks obtained with optical readout with timing information from fast photon detectors or transparent anodes for charge readout, 3D reconstruction of particle trajectories can be performed and permits the realisation of optically read out time projection chambers. Combining readily available high performance imaging sensors with compatible

  13. Detector Unit

    CERN Multimedia

    1960-01-01

    Original detector unit of the Instituut voor Kernfysisch Onderzoek (IKO) BOL project. This detector unit shows that silicon detectors for nuclear physics particle detection were already developed and in use in the 1960's in Amsterdam. Also the idea of putting 'strips' onto the silicon for high spatial resolution of a particle's impact on the detector were implemented in the BOL project which used 64 of these detector units. The IKO BOL project with its silicon particle detectors was designed, built and operated from 1965 to roughly 1977. Detector Unit of the BOL project: These detectors, notably the ‘checkerboard detector’, were developed during the years 1964-1968 in Amsterdam, The Netherlands, by the Natuurkundig Laboratorium of the N.V. Philips Gloeilampen Fabrieken. This was done in close collaboration with the Instituut voor Kernfysisch Onderzoek (IKO) where the read-out electronics for their use in the BOL Project was developed and produced.

  14. A Weak Value Based QKD Protocol Robust Against Detector Attacks

    Science.gov (United States)

    Troupe, James

    2015-03-01

    We propose a variation of the BB84 quantum key distribution protocol that utilizes the properties of weak values to insure the validity of the quantum bit error rate estimates used to detect an eavesdropper. The protocol is shown theoretically to be secure against recently demonstrated attacks utilizing detector blinding and control and should also be robust against all detector based hacking. Importantly, the new protocol promises to achieve this additional security without negatively impacting the secure key generation rate as compared to that originally promised by the standard BB84 scheme. Implementation of the weak measurements needed by the protocol should be very feasible using standard quantum optical techniques.

  15. An integrated electrochemical device based on immunochromatographic test strip and enzyme labels for sensitive detection of disease-related biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Zhexiang; Wang, Jun; Wang, Hua; Li, Yao Q.; Lin, Yuehe

    2012-05-30

    A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. The sensor was further utilized to detect HBsAg in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population

  16. Dual Immunomagnetic Nanobeads-Based Lateral Flow Test Strip for Simultaneous Quantitative Detection of Carcinoembryonic Antigen and Neuron Specific Enolase

    Science.gov (United States)

    Lu, Wenting; Wang, Kan; Xiao, Kun; Qin, Weijian; Hou, Yafei; Xu, Hao; Yan, Xinyu; Chen, Yanrong; Cui, Daxiang; He, Jinghua

    2017-01-01

    A novel immunomagnetic nanobeads -based lateral flow test strip was developed for the simultaneous quantitative detection of neuron specific enolase (NSE) and carcinoembryonic antigen (CEA), which are sensitive and specific in the clinical diagnosis of small cell lung cancer. Using this nanoscale method, high saturation magnetization, carboxyl-modified magnetic nanobeads were successfully synthesized. To obtain the immunomagnetic probes, a covalent bioconjugation of the magnetic nanobeads with the antibody of NSE and CEA was carried out. The detection area contained test line 1 and test line 2 which captured the immune complexes sensitively and formed sandwich complexes. In this assay, cross-reactivity results were negative and both NSE and CEA were detected simultaneously with no obvious influence on each other. The magnetic signal intensity of the nitrocellulose membrane was measured by a magnetic assay reader. For quantitative analysis, the calculated limit of detection was 0.094 ng/mL for NSE and 0.045 ng/mL for CEA. One hundred thirty clinical samples were used to validate the test strip which exhibited high sensitivity and specificity. This dual lateral flow test strip not only provided an easy, rapid, simultaneous quantitative detection strategy for NSE and CEA, but may also be valuable in automated and portable diagnostic applications. PMID:28186176

  17. Experimental characterization of semiconductor-based thermal neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); Bortot, D.; Pola, A.; Introini, M.V.; Lorenzoli, M. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN—Milano, Via Celoria 16, 20133 Milano (Italy); Gómez-Ros, J.M. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Sacco, D. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); INAIL—DIT, Via di Fontana Candida 1, 00040 Monteporzio Catone (Italy); Esposito, A.; Gentile, A.; Buonomo, B. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); Palomba, M.; Grossi, A. [ENEA Triga RC-1C.R. Casaccia, via Anguillarese 301, 00060 S. Maria di Galeria, Roma (Italy)

    2015-04-21

    In the framework of NESCOFI@BTF and NEURAPID projects, active thermal neutron detectors were manufactured by depositing appropriate thickness of {sup 6}LiF on commercially available windowless p–i–n diodes. Detectors with different radiator thickness, ranging from 5 to 62 μm, were manufactured by evaporation-based deposition technique and exposed to known values of thermal neutron fluence in two thermal neutron facilities exhibiting different irradiation geometries. The following properties of the detector response were investigated and presented in this work: thickness dependence, impact of parasitic effects (photons and epithermal neutrons), linearity, isotropy, and radiation damage following exposure to large fluence (in the order of 10{sup 12} cm{sup −2})

  18. Modelling of solidification processing and continuous strip casting for copper-base alloys

    Energy Technology Data Exchange (ETDEWEB)

    Mahmoudi, Jafar [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Materials Processing

    2000-04-01

    An experimental and numerical study was carried out to investigate the solidification process in a copper continuous strip casting process. Heat flow and solidification process has been experimentally studied. Cooling curves during solidification were registered using a thermocouple of type K connected to a data acquisition system. Temperature measurements in the mould and cooling water were also performed. The numerical model considers a generalized set of mass, momentum and heat equations that is valid for the solid, liquid and solidification interval in the cast. A k-{epsilon} turbulence model, produced with the commercial program CFX, is used to analyse the solidification process of pure copper in the mould region of the caster. The fluid flow, temperature and heat flux distributions in the mould region of the caster were computed. The shape and location of the solidification front were also determined. The effects of the parameters such as heat transfer coefficient, casting speed, casting temperature, heat of fusion and specific heat on the shape and location of the solidification front and the heat transport at the mould-cast interface were investigated. The predicted temperature and heat flux distributions were compared with experimental measurements, and reasonable agreement was obtained. The solidification behaviour of pure copper and different copper base alloys has been studied. A series of solidification experiments using DTA furnace, mirror furnace and levitation technique were performed on different copper-base alloys. The undercooling, cooling rates of the liquid and the solid states, solidification times and temperatures were evaluated from the curves. The cooling curves for different samples were simulated using a FEM solidification program. It was found that the calculated values of the heat of fusion were much lower than the tabulated ones. The fraction of solid formed before quenching, in the DTA experiments, has been observed to be much higher

  19. A mode III moving interfacial crack based on strip magneto-electric polarization saturation model

    International Nuclear Information System (INIS)

    Xia, Xiaodong; Zhong, Zheng

    2015-01-01

    This paper deals with a mode III Yoffe-type interfacial crack propagating subsonically under the moving strip magneto-electric saturation model. Nonlinear effects are characterized by different magnetic and electric saturation strips around the crack tip. Employing the extended Stroh method, we obtain generalized moving interfacial dislocation densities analytically under impermeable magneto-electric crack boundary conditions. The generalized intensity factor and local energy release rate with nonlinear effects are derived as fracture parameters for the moving magneto-electro-elastic (MEE) interfacial crack. Numerical results are presented to show the characteristics of fracture dominant parameters with respect to the loading as well as the propagation velocity. In addition, a dimensionless parameter defined by the ratio of the volume fraction of the composite constituents is proposed to evaluate the influences of the MEE bimaterial properties. This research will give us ideas on material selection for optimizing the fracture toughness of MEE composites. (paper)

  20. A phononic crystal strip based on silicon for support tether applications in silicon-based MEMS resonators and effects of temperature and dopant on its band gap characteristics

    Directory of Open Access Journals (Sweden)

    Thi Dep Ha

    2016-04-01

    Full Text Available Phononic crystals (PnCs and n-type doped silicon technique have been widely employed in silicon-based MEMS resonators to obtain high quality factor (Q as well as temperature-induced frequency stability. For the PnCs, their band gaps play an important role in the acoustic wave propagation. Also, the temperature and dopant doped into silicon can cause the change in its material properties such as elastic constants, Young’s modulus. Therefore, in order to design the simultaneous high Q and frequency stability silicon-based MEMS resonators by two these techniques, a careful design should study effects of temperature and dopant on the band gap characteristics to examine the acoustic wave propagation in the PnC. Based on these, this paper presents (1 a proposed silicon-based PnC strip structure for support tether applications in low frequency silicon-based MEMS resonators, (2 influences of temperature and dopant on band gap characteristics of the PnC strips. The simulation results show that the largest band gap can achieve up to 33.56 at 57.59 MHz and increase 1280.13 % (also increase 131.89 % for ratio of the widest gaps compared with the counterpart without hole. The band gap properties of the PnC strips is insignificantly effected by temperature and electron doping concentration. Also, the quality factor of two designed length extensional mode MEMS resonators with proposed PnC strip based support tethers is up to 1084.59% and 43846.36% over the same resonators with PnC strip without hole and circled corners, respectively. This theoretical study uses the finite element analysis in COMSOL Multiphysics and MATLAB softwares as simulation tools. This findings provides a background in combination of PnC and dopant techniques for high performance silicon-based MEMS resonators as well as PnC-based MEMS devices.

  1. Novel detectors for silicon based microdosimetry, their concepts and applications

    Science.gov (United States)

    Rosenfeld, Anatoly B.

    2016-02-01

    This paper presents an overview of the development of semiconductor microdosimetry and the most current (state-of-the-art) Silicon on Insulator (SOI) detectors for microdosimetry based mainly on research and development carried out at the Centre for Medical Radiation Physics (CMRP) at the University of Wollongong with collaborators over the last 18 years. In this paper every generation of CMRP SOI microdosimeters, including their fabrication, design, and electrical and charge collection characterisation are presented. A study of SOI microdosimeters in various radiation fields has demonstrated that under appropriate geometrical scaling, the response of SOI detectors with the well-known geometry of microscopically sensitive volumes will record the energy deposition spectra representative of tissue cells of an equivalent shape. This development of SOI detectors for microdosimetry with increased complexity has improved the definition of microscopic sensitive volume (SV), which is modelling the deposition of ionising energy in a biological cell, that are led from planar to 3D SOI detectors with an array of segmented microscopic 3D SVs. The monolithic ΔE-E silicon telescope, which is an alternative to the SOI silicon microdosimeter, is presented, and as an example, applications of SOI detectors and ΔE-E monolithic telescope for microdosimetery in proton therapy field and equivalent neutron dose measurements out of field are also presented. An SOI microdosimeter "bridge" with 3D SVs can derive the relative biological effectiveness (RBE) in 12C ion radiation therapy that matches the tissue equivalent proportional counter (TEPC) quite well, but with outstanding spatial resolution. The use of SOI technology in experimental microdosimetry offers simplicity (no gas system or HV supply), high spatial resolution, low cost, high count rates, and the possibility of integrating the system onto a single device with other types of detectors.

  2. Design of a fast multi-hit position sensitive detector based on a CCD camera

    CERN Document Server

    Renaud, L; Da Costa, G; Deconihout, B

    2002-01-01

    A new position sensitive detector has been designed for time-of-flight mass spectrometry. It combines a double micro-channel plate stage with a phosphor screen, the conductive coating of which is divided into an array of strip-like-shaped anodes. Time-of-flight signals are measured on the strip array with a 0.5 ns resolution, while a CCD camera records light-spots generated by ion impacts on the phosphor screen. With this particular imaging device, it is possible to accurately assign time-of-flight to positions recorded by the camera. This paper describes the main features of this new position sensitive detector and results obtained with a three-dimensional atom probe are presented.

  3. Temperature detectors on irradiated silicon base

    International Nuclear Information System (INIS)

    Karimov, M.; Dzhalelov, M.A.; Kurbanov, A.O.

    2005-01-01

    It is well known, that the most suitable for thermal resistors production is compensated silicon with impurities forming deep lying in forbidden zone, having big negative resistance temperature coefficients (RTC). In the capacity of initial materials for thermal resistors with negative RTC the n-type monocrystalline silicon with specific resistance ∼30 Ω·cm at 300 K is applied. Before the irradiation the phosphorus diffusion is realizing at temperature ∼1000 deg. C for 10 min. Irradiation is putting into practise by WWR-SM reactor fast neutrons within the range (7-10)·10 13 cm -2 . The produced resistors have nominal resistance range (8-20)·10 3 Ω·cm, coefficient of the thermal sensitivity B=4000-6000 deg. C., RTC α 300K =4-6.6 %/grad. It is shown, that offered method allows to obtain same type resistors characteristics on the base of neutron-irradiated material

  4. Potential Impact of a New GEM-based Detector on CMS Triggering

    CERN Document Server

    INSPIRE-00212096; Abbaneo, D.; Abbrescia, M.; Abi Akl, M.; Armaingaud, C.; Aspell, P.; Assran, Y.; Bally, S.; Ban, Y.; Barria, P.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Cai, J.; Calabria, C.; Cauwenbergh, S.; Celik, A.; Christiansen, J.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; De Lentdecker, G.; De Oliveira, R.; de Robertis, G.; Dildick, S.; Ferry, S.; Flanagan, W.; Gilmore, J.; Gutierrez, A.; Hoepfner, K.; Hohlmann, M.; Kamon, T.; Karchin, P.E.; Khotilovich, V.; Krutelyov, S.; Loddo, F.; Maerschalk, T.; Magazzu, G.; Maggi, M.; Maghrbi, Y.; Marchioro, A.; Marinov, A.; Merlin, J.A.; Nuzzo, S.; Oliveri, E.; Philipps, B.; Piccolo, D.; Postema, H.; Radi, A.; Radogna, R.; Raffone, G.; Ranieri, A.; Rodrigues, A.; Ropelewski, L.; Safonov, A.; Sakharov, A.; Salva, S.; Saviano, G.; Sharma, A.; Tatarinov, A.; Teng, H.; Turini, N.; Twigger, J.; Tytgat, M.; van Stenis, M.; Verhagen, E.; Yang, Y.; Zaganidis, N.; Zenoni, F.

    2013-01-01

    With the increases in the LHC instantaneous luminosity, maintaining effective triggering and avoiding dead time will become especially challenging. As the sensitivity of many physics studies, depends critically on the ability to maintain relatively low muon momentum thresholds, the identification of potential improvements in triggering is particularly important. The addition of a new muon detector to the existing CMS muon system in the very forward region allows for a substantial improvement in the performance of muon triggering. Integration of the new detector and the existing Cathode Strip Chamber system can improve the muon trigger momentum resolution due to an increase in the lever arm for the measurement of the muon bending angle.

  5. Neutron detector based on lithiated sol-gel glass

    CERN Document Server

    Wallace, S; Miller, L F; Dai, S

    2002-01-01

    A neutron detector technology is demonstrated based on sup 6 Li/ sup 1 sup 0 B doped sol-gel glass. The detector is a sol-gel glass film coated silicon surface barrier detector (SBD). The ionized charged particles from (n, alpha) reactions in the sol-gel film enter the SBD and are counted. Data showing that gamma-ray pulse amplitudes interfere with identifying charged particles that exit the film layer with energies below the gamma-ray energy is presented. Experiments were performed showing the effect of sup 1 sup 3 sup 7 Cs and sup 6 sup 0 Co gamma rays on the SBD detector. The reaction product energies of the triton and alpha particles from sup 6 Li are significantly greater than the energies of the Compton electrons from high-energy gamma rays, allowing the measurement of neutrons in a high gamma background. The sol-gel radiation detection technology may be applicable to the characterization of transuranic waste, spent nuclear fuel and to the monitoring of stored plutonium.

  6. Gamma-ray imaging with thick position-sensitive silicon detectors

    International Nuclear Information System (INIS)

    Rowland-Fitzgerald, C.; Kurfess, J.D.; Phlips, B.F.; Wulf, E.A.; Novikova, E.I.

    2006-01-01

    The construction of a prototype Compton imager at the Naval Research Laboratory (NRL) is nearly complete. The instrument is an 8-layer stacked silicon detector and is based on the '3-Compton' energy reconstruction technique. The silicon detectors are 2 mm thick, double-sided, orthogonal strip detectors. Instrumentation and performance of the individual detectors and layers are presented along with simulations of the completed instrument. Implications of the instrument for real world applications and future work involving the final assembly are discussed

  7. A risk-based approach to flammable gas detector spacing.

    Science.gov (United States)

    Defriend, Stephen; Dejmek, Mark; Porter, Leisa; Deshotels, Bob; Natvig, Bernt

    2008-11-15

    Flammable gas detectors allow an operating company to address leaks before they become serious, by automatically alarming and by initiating isolation and safe venting. Without effective gas detection, there is very limited defense against a flammable gas leak developing into a fire or explosion that could cause loss of life or escalate to cascading failures of nearby vessels, piping, and equipment. While it is commonly recognized that some gas detectors are needed in a process plant containing flammable gas or volatile liquids, there is usually a question of how many are needed. The areas that need protection can be determined by dispersion modeling from potential leak sites. Within the areas that must be protected, the spacing of detectors (or alternatively, number of detectors) should be based on risk. Detector design can be characterized by spacing criteria, which is convenient for design - or alternatively by number of detectors, which is convenient for cost reporting. The factors that influence the risk are site-specific, including process conditions, chemical composition, number of potential leak sites, piping design standards, arrangement of plant equipment and structures, design of isolation and depressurization systems, and frequency of detector testing. Site-specific factors such as those just mentioned affect the size of flammable gas cloud that must be detected (within a specified probability) by the gas detection system. A probability of detection must be specified that gives a design with a tolerable risk of fires and explosions. To determine the optimum spacing of detectors, it is important to consider the probability that a detector will fail at some time and be inoperative until replaced or repaired. A cost-effective approach is based on the combined risk from a representative selection of leakage scenarios, rather than a worst-case evaluation. This means that probability and severity of leak consequences must be evaluated together. In marine and

  8. Operational experience of ATLAS SCT and Pixel Detector

    CERN Document Server

    Kocian, Martin; The ATLAS collaboration

    2017-01-01

    The ATLAS Inner Detector based on silicon sensors is consisting of a strip detector (SCT) and a pixel detector. It is the crucial component for vertexing and tracking in the ATLAS experiment. With the excellent performance of the LHC well beyond the original specification the silicon tracking detectors are facing substantial challenges in terms of data acquisition, radiation damage to the sensors, and SEUs in the readout ASICs. The approaches on how the detector systems cope with the demands of high luminosity operation while maintaining excellent performance through hardware upgrades, software and firmware algorithms, and operational settings, are presented.

  9. An integrated electrochemical device based on immunochromatographic test strip and enzyme labels for sensitive detection of disease-related biomarkers.

    Science.gov (United States)

    Zou, Zhe-Xiang; Wang, Jun; Wang, Hua; Li, Yao-Qun; Lin, Yuehe

    2012-05-30

    A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. Under optimal conditions, this sensor was capable of detecting a minimum of 0.3 ng mL(-1) (S/N=3) HBsAg with a wide linear concentration range from 1 to 500 ng mL(-1). The sensor was further utilized to detect HBsAg spiked in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. SENTIRAD—An innovative personal radiation detector based on a scintillation detector and a silicon photomultiplier

    Science.gov (United States)

    Osovizky, A.; Ginzburg, D.; Manor, A.; Seif, R.; Ghelman, M.; Cohen-Zada, I.; Ellenbogen, M.; Bronfenmakher, V.; Pushkarsky, V.; Gonen, E.; Mazor, T.; Cohen, Y.

    2011-10-01

    The alarming personal radiation detector (PRD) is a device intended for Homeland Security (HLS) applications. This portable device is designed to be worn or carried by security personnel to detect photon-emitting radioactive materials for the purpose of crime prevention. PRD is required to meet the scope of specifications defined by various HLS standards for radiation detection. It is mandatory that the device be sensitive and simultaneously small, pocket-sized, of robust mechanical design and carriable on the user's body. To serve these specialized purposes and requirements, we developed the SENTIRAD, a new radiation detector designed to meet the performance criteria established for counterterrorist applications. SENTIRAD is the first commercially available PRD based on a CsI(Tl) scintillation crystal that is optically coupled with a silicon photomultiplier (SiPM) serving as a light sensor. The rapidly developing technology of SiPM, a multipixel semiconductor photodiode that operates in Geiger mode, has been thoroughly investigated in previous studies. This paper presents the design considerations, constraints and radiological performance relating to the SENTIRAD radiation sensor.

  11. [Research on pattern recognition of the component stripping rule based on zuojinwan and its similar formulaes combined chemometrics methods].

    Science.gov (United States)

    Wang, Chao-run; He, Qun; Deng, Gui-ming; Su, Wei-wei

    2012-05-01

    To establish a method of HPLC relative dissolution rate for reorganizing and validating the dissolution pattern of Zuojinwan and its similar formulaes. Selected the relative dissolution rate of the components of HPLC chromatogram of zuojinwan and its similar formulaes as the index, establish a HPLC relative dissolution rate of Zuojinwan and its similar formulaes, and made the pattern recognition research on the dissolution of pattern based on using the principal component analysis, cluster analysis and Fisher discriminant analysis. Three principal components divided from principal component analysis could summary comprehensively the twenty indicators of HPLC relative dissolution rate of Zuojinwan and its similar formulaes; Basing on the principal component analysis, divided the components dissolved rule of zuojinwan and its similar formulaes into six classes through cluster analysis, and established the corresponding Fisher discriminant function, which return sentence accuracy rate was 100%. The evaluation method established preliminarily of components stripping rules of chemical pattern recognition of Zuojinwan and its similar formulaes, can make the accurate, reliable, objective identification and validation of the stripping rule of zuojinwan and its similar formulaes.

  12. Aptamer-based fluorescence-quenching lateral flow strip for rapid detection of mercury (II) ion in water samples.

    Science.gov (United States)

    Wu, Ze; Shen, Haicong; Hu, Junhui; Fu, Qiangqiang; Yao, Cuize; Yu, Shiting; Xiao, Wei; Tang, Yong

    2017-09-01

    Divalent mercury ion (Hg 2+ ) is one of the most common and stable forms of mercury pollution. In this study, a skillfully designed lateral flow strip (LFS) was developed for sensitive detection of Hg 2+ in river water samples. Aptamer, a specific oligonucleotide probe, was used to selectively identify and target Hg 2+ instead of antibody in traditional immunechromatographic strips; and the fluorescence-quenching system was used to generate positive and low background florescence signals in the competitive-likely LFS. The linear detection range of the LFS for Hg 2+ was 0.13 ng mL -1 to 4 ng mL -1 and the limit of detection (LOD) was 0.13 ng mL -1 . This test provided results in 15 min and demonstrated high specificity. For detection of Hg 2+ in river water, the results were consistent with inductively coupled plasma-mass spectrometry measurements. The aptamer-based fluorescence-quenching LFS was shown to provide a reliable, accurate method for rapid detection of mercury contamination. Graphical Abstract The principle of the aptamer-based fluorescence-quenching LFS.

  13. Sensitive and Quantitative Detection of C-Reaction Protein Based on Immunofluorescent Nanospheres Coupled with Lateral Flow Test Strip.

    Science.gov (United States)

    Hu, Jiao; Zhang, Zhi-Ling; Wen, Cong-Ying; Tang, Man; Wu, Ling-Ling; Liu, Cui; Zhu, Lian; Pang, Dai-Wen

    2016-06-21

    Sensitive and quantitative detection of protein biomarkers with a point-of-care (POC) assay is significant for early diagnosis, treatment, and prognosis of diseases. In this paper, a quantitative lateral flow assay with high sensitivity for protein biomarkers was established by utilizing fluorescent nanospheres (FNs) as reporters. Each fluorescent nanosphere (FN) contains 332 ± 8 CdSe/ZnS quantum dots (QDs), leading to its superstrong luminescence, 380-fold higher than that of one QD. Then a detection limit of 27.8 pM C-reaction protein (CRP) could be achieved with an immunofluorescent nanosphere (IFN)-based lateral flow test strip. The assay was 257-fold more sensitive than that with a conventional Au-based lateral flow test strip for CRP detection. Besides, the fluorescence intensity of FNs and bioactivity of IFNs were stable during 6 months of storage. Hence, the assay owns good reproducibility (intra-assay variability of 5.3% and interassay variability of 6.6%). Furthermore, other cancer biomarkers (PSA, CEA, AFP) showed negative results by this method, validating the excellent specificity of the method. Then the assay was successfully applied to quantitatively detect CRP in peripheral blood plasma samples from lung cancer and breast cancer patients, and healthy people, facilitating the diagnosis of lung cancer. It holds a good prospect of POC protein biomarker detection.

  14. A beam monitor based on MPGD detectors for hadron therapy

    Science.gov (United States)

    Altieri, P. R.; Di Benedetto, D.; Galetta, G.; Intonti, R. A.; Mercadante, A.; Nuzzo, S.; Verwilligen, P.

    2018-02-01

    Remarkable scientific and technological progress during the last years has led to the construction of accelerator based facilities dedicated to hadron therapy. This kind of technology requires precise and continuous control of position, intensity and shape of the ions or protons used to irradiate cancers. Patient safety, accelerator operation and dose delivery should be optimized by a real time monitoring of beam intensity and profile during the treatment, by using non-destructive, high spatial resolution detectors. In the framework of AMIDERHA (AMIDERHA - Enhanced Radiotherapy with HAdron) project funded by the Ministero dell'Istruzione, dell'Università e della Ricerca (Italian Ministry of Education and Research) the authors are studying and developing an innovative beam monitor based on Micro Pattern Gaseous Detectors (MPDGs) characterized by a high spatial resolution and rate capability. The Monte Carlo simulation of the beam monitor prototype was carried out to optimize the geometrical set up and to predict the behavior of the detector. A first prototype has been constructed and successfully tested using 55Fe, 90Sr and also an X-ray tube. Preliminary results on both simulations and tests will be presented.

  15. Abdominal Applications of a Novel Detector-Based Spectral CT.

    Science.gov (United States)

    Fulton, Nicholas; Rajiah, Prabhakar

    Detector-based spectral computed tomography (SDCT) is a recently introduced technology that uses a single x-ray tube and 2 layers of detectors to simultaneously collect low- and high-energy data. In this article, we provide an overview of this novel SDCT technology in abdominal imaging. Several applications of SDCT in abdominal imaging are discussed and illustrated, along with a brief description of current literature on the status of dual-energy computed tomography in these applications. This includes urinary calculus composition, characterization of masses (renal, adrenal, hepatic, and others), tumor perfusion, improving vascular contrast, improving lesion conspicuity, decreasing artifacts, and reducing radiation dose. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Beyond the Sparsity-Based Target Detector: A Hybrid Sparsity and Statistics Based Detector for Hyperspectral Images.

    Science.gov (United States)

    Du, Bo; Zhang, Yuxiang; Zhang, Liangpei; Tao, Dacheng

    2016-08-18

    Hyperspectral images provide great potential for target detection, however, new challenges are also introduced for hyperspectral target detection, resulting that hyperspectral target detection should be treated as a new problem and modeled differently. Many classical detectors are proposed based on the linear mixing model and the sparsity model. However, the former type of model cannot deal well with spectral variability in limited endmembers, and the latter type of model usually treats the target detection as a simple classification problem and pays less attention to the low target probability. In this case, can we find an efficient way to utilize both the high-dimension features behind hyperspectral images and the limited target information to extract small targets? This paper proposes a novel sparsitybased detector named the hybrid sparsity and statistics detector (HSSD) for target detection in hyperspectral imagery, which can effectively deal with the above two problems. The proposed algorithm designs a hypothesis-specific dictionary based on the prior hypotheses for the test pixel, which can avoid the imbalanced number of training samples for a class-specific dictionary. Then, a purification process is employed for the background training samples in order to construct an effective competition between the two hypotheses. Next, a sparse representation based binary hypothesis model merged with additive Gaussian noise is proposed to represent the image. Finally, a generalized likelihood ratio test is performed to obtain a more robust detection decision than the reconstruction residual based detection methods. Extensive experimental results with three hyperspectral datasets confirm that the proposed HSSD algorithm clearly outperforms the stateof- the-art target detectors.

  17. Modeling of a bimetallic MEMS-based infrared detector

    Science.gov (United States)

    Pevtsov, E. Ph; Breev, S. V.; Demenkova, T. A.

    2018-01-01

    In work techniques of calculations of the key parameters of the bimetal capacitive IR detectors matrix are presented. Sensitivity characteristics of the bimetal detector were calculated and prototype model of detector in the form of bimetallic console was produced. The possibility of use of capacitive MEMS-receivers on basis of bimetallic effect as an alternative to pyroelectric and microbolometer IR detectors is shown.

  18. Selective chemical stripping

    Science.gov (United States)

    Malavallon, Olivier

    1995-04-01

    At the end of the 80's, some of the large European airlines expressed a wish for paint systems with improved strippability on their aircraft, allowing the possibility to strip down to the primer without altering it, using 'mild' chemical strippers based on methylene chloride. These improvements were initially intended to reduce costs and stripping cycle times while facilitating rapid repainting, and this without the need to change the conventionally used industrial facilities. The level of in-service performance of these paint systems was to be the same as the previous ones. Requirements related to hygiene safety and the environment were added to these initial requirements. To meet customers' expectations, Aerospatiale, within the Airbus Industry GIE, formed a work group. This group was given the task of specifying, following up the elaboration and qualifying the paint systems allowing requirements to be met, in relation with the paint suppliers and the airlines. The analysis made in this report showed the interest of transferring as far upstream as possible (to paint conception level) most of the technical constraints related to stripping. Thus, the concept retained for the paint system, allowing selective chemical stripping, is a 3-coat system with characteristics as near as possible to the previously used paints.

  19. A fast-neutron detection detector based on fission material and large sensitive 4H silicon carbide Schottky diode detector

    Science.gov (United States)

    Liu, Linyue; Liu, Jinliang; Zhang, Jianfu; Chen, Liang; Zhang, Xianpeng; Zhang, Zhongbing; Ruan, Jinlu; Jin, Peng; Bai, Song; Ouyang, Xiaoping

    2017-12-01

    Silicon carbide radiation detectors are attractive in the measurement of the total numbers of pulsed fast neutrons emitted from nuclear fusion and fission devices because of high neutron-gamma discrimination and good radiation resistance. A fast-neutron detection system was developed based on a large-area 4H-SiC Schottky diode detector and a 235U fission target. Excellent pulse-height spectra of fission fragments induced by mono-energy deuterium-tritium (D-T) fusion neutrons and continuous energy fission neutrons were obtained. The detector is proven to be a good candidate for pulsed fast neutron detection in a complex radiation field.

  20. Design and development of a vertex reconstruction for the CMS (Compact Muon Solenoid) data. Study of gaseous and silicon micro-strips detectors (MSGC); Conception d'un algorithme de reconstruction de vertex pour les donnees de CMS. Etude de detecteurs gazeux (MSGC) et silicium a micropistes

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, St

    2002-12-01

    The work presented in this thesis has contributed to the development of the Compact Muon Solenoid detector (CMS) that will be installed at the future Large Hadron Collider (LHC) which will start running in summer 2007. This report is organised in three parts: the study of gaseous detectors and silicon micro-strips detectors, and a development of a software for the reconstruction and analysis of CMS data in the framework of ORCA. First, the micro-strips gaseous detectors (MSGC) study was on the ultimate critical irradiation test before their substitution in the CMS tracker. This test showed a really small number of lost anodes and a stable signal to noise ratio. This test proved that the described MSGC fulfill all the requirements to be integrated in the CMS tracker. The following contribution described a study of silicon micro-strips detectors and its electronics exposed to a 40 MHz bunched LHC like beam. These tests indicated a good behaviour of the data acquisition and control system. The signal to noise ratio, the bunch crossing identification and the cluster finding efficiency had also be analysed. The last study concern the design and the development of an ORCA algorithm dedicates to secondary vertex reconstruction. This iterative algorithm aims to be use for b tagging. This part analyse also primary vertex reconstruction in events without and with pile up. (author)

  1. The Effect of Personalization on Smartphone-Based Fall Detectors

    Directory of Open Access Journals (Sweden)

    Carlos Medrano

    2016-01-01

    Full Text Available The risk of falling is high among different groups of people, such as older people, individuals with Parkinson's disease or patients in neuro-rehabilitation units. Developing robust fall detectors is important for acting promptly in case of a fall. Therefore, in this study we propose to personalize smartphone-based detectors to boost their performance as compared to a non-personalized system. Four algorithms were investigated using a public dataset: three novelty detection algorithms—Nearest Neighbor (NN, Local Outlier Factor (LOF and One-Class Support Vector Machine (OneClass-SVM—and a traditional supervised algorithm, Support Vector Machine (SVM. The effect of personalization was studied for each subject by considering two different training conditions: data coming only from that subject or data coming from the remaining subjects. The area under the receiver operating characteristic curve (AUC was selected as the primary figure of merit. The results show that there is a general trend towards the increase in performance by personalizing the detector, but the effect depends on the individual being considered. A personalized NN can reach the performance of a non-personalized SVM (average AUC of 0.9861 and 0.9795, respectively, which is remarkable since NN only uses activities of daily living for training.

  2. OBSERVATIONAL SELECTION EFFECTS WITH GROUND-BASED GRAVITATIONAL WAVE DETECTORS

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hsin-Yu; Holz, Daniel E. [University of Chicago, Chicago, Illinois 60637 (United States); Essick, Reed; Vitale, Salvatore; Katsavounidis, Erik [LIGO, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    2017-01-20

    Ground-based interferometers are not perfect all-sky instruments, and it is important to account for their behavior when considering the distribution of detected events. In particular, the LIGO detectors are most sensitive to sources above North America and the Indian Ocean, and as the Earth rotates, the sensitive regions are swept across the sky. However, because the detectors do not acquire data uniformly over time, there is a net bias on detectable sources’ right ascensions. Both LIGO detectors preferentially collect data during their local night; it is more than twice as likely to be local midnight than noon when both detectors are operating. We discuss these selection effects and how they impact LIGO’s observations and electromagnetic (EM) follow-up. Beyond galactic foregrounds associated with seasonal variations, we find that equatorial observatories can access over 80% of the localization probability, while mid-latitudes will access closer to 70%. Facilities located near the two LIGO sites can observe sources closer to their zenith than their analogs in the south, but the average observation will still be no closer than 44° from zenith. We also find that observatories in Africa or the South Atlantic will wait systematically longer before they can begin observing compared to the rest of the world; though, there is a preference for longitudes near the LIGOs. These effects, along with knowledge of the LIGO antenna pattern, can inform EM follow-up activities and optimization, including the possibility of directing observations even before gravitational-wave events occur.

  3. ATLAS Strips Upgrade

    CERN Document Server

    Miñano, Mercedes

    2009-01-01

    It is foreseen to increase the luminosity of the LHC at CERN around 2020 by about an order of magnitude (SLHC). The ATLAS experiment will require a new particle tracking system for SLHC operation in order to cope with the increase in background events by about one order of magnitude at the higher luminosity. , an all silicon detector with enhanced radiation hardness is being designed. A massive R&D programme, involving many particles physics groups and several leadings manufacturers of silicon detectors for particle physics, is underway to develop silicon sensors with sufficient radiation hardness. In this framework new sensor materials like p-type silicon and the 3D technology are investigated. In parallel, the SCT commissioning experience has taught us to look into alternative module concepts, in which higher levels of integration are combined with the modularity of the SCT approach. We will report on the status of the R&D projects on radiation hard silicon strip detectors for particle physics, link...

  4. Development of a 3D CZT detector prototype for Laue Lens telescope

    DEFF Research Database (Denmark)

    Caroli, Ezio; Auricchio, Natalia; Del Sordo, Stefano

    2010-01-01

    We report on the development of a 3D position sensitive prototype suitable as focal plane detector for Laue lens telescope. The basic sensitive unit is a drift strip detector based on a CZT crystal, (~19×8 mm2 area, 2.4 mm thick), irradiated transversally to the electric field direction. The anode...

  5. An Improved VI-CFAR Detector Based on GOS

    OpenAIRE

    Zhao Likai; Li Sen; Hu Guangzhao

    2016-01-01

    In combination with the advantages of CA-CFAR, GO-CFAR and SO-CFAR algorithm, the VI-CFAR has strong adaptability both in homogeneous and non-homogeneous environment. However, if the interfering targets are present in both the halves of the reference sliding windows, the use of the window with the smallest mean is affected by them and therefore results in a performance degradation. In order to overcome the shortcoming, an improved VI-CFAR detector based on GOS (IVI-CFAR) is proposed in this p...

  6. Recent state of CdTe-based radiation detectors

    International Nuclear Information System (INIS)

    Ohno, R.

    2004-01-01

    Recent state for development of CdTe-based radiation detectors is reviewed. The progress of the technologies such as the crystal growth of CdTe and CdZnTe, the deposition of electrodes on the crystal, the design of read out ASIC, and the bonding between crystal and ASIC, opened the way for the development of imaging devices for practical uses. A X-ray imager for non destructive inspections and a gamma ray imager for small animal radioisotope experiments or nuclear medicine are presented as examples. (author)

  7. Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed

    Directory of Open Access Journals (Sweden)

    Wang ZZ

    2014-04-01

    Full Text Available Zhizeng Wang,1 Dejuan Zhi,2 Yang Zhao,1 Hailong Zhang,2 Xin Wang,2 Yi Ru,1 Hongyu Li1,2 1MOE Key Laboratory of Cell Activities and Stress Adaptations, School of Life Sciences, Lanzhou University, Lanzhou, People's Republic of China; 2Institute of Microbiology and Biochemical Pharmacy, School of Pharmaceutics, Lanzhou University, Lanzhou, People's Republic of China Abstract: Although high melamine (MEL intake has been proven to cause serious health problems, MEL is sometimes illegally added to milk products and animal feed, arousing serious food safety concerns. A satisfactory method of detecting MEL in onsite or in-home testing is in urgent need of development. This work aimed to explore a rapid, convenient, and cost-effective method of identifying MEL in milk products or other food by colloidal selenium-based lateral flow immunoassay. Colloidal selenium was synthesized by L-ascorbic acid to reduce seleninic acid at room temperature. After conjugation with a monoclonal antibody anti-MEL, a test strip was successfully prepared. The detection limit of the test strip reached 150 µg/kg, 1,000 µg/kg, and 800 µg/kg in liquid milk, milk powder, and animal feed, respectively. No cross-reactions with homologues cyanuric acid, cyanurodiamide, or ammelide were found. Moreover, the MEL test strip can remain stable after storage for 1 year at room temperature. Our results demonstrate that the colloidal selenium MEL test strip can detect MEL in adulterated milk products or animal feed conveniently, rapidly, and sensitively. In contrast with a colloidal gold MEL test strip, the colloidal selenium MEL test strip was easy to prepare and more cost-efficient. Keywords: melamine, selenium nanoparticles, test strip, milk, animal feed, dairy food

  8. A micro-TCA based data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer

    Science.gov (United States)

    Lenzi, T.

    2017-01-01

    The Gas Electron Multiplier (GEM) upgrade project aims at improving the performance of the muon spectrometer of the Compact Muon Solenoid (CMS) experiment which will suffer from the increase in luminosity of the Large Hadron Collider (LHC). The GEM collaboration proposes to instrument the first muon station with Triple-GEM detectors, a technology which has proven to be resistant to high fluxes of particles. The architecture of the readout system is based on the use of the microTCA standard hosting FPGA-based Advanced Mezzanine Card (AMC) and of the Versatile Link with the GBT chipset to link the on-detector electronics to the micro-TCA boards. For the front-end electronics a new ASIC, called VFAT3, is being developed. On the detector, a Xilinx Virtex-6 FPGA mezzanine board, called the OptoHybrid, has to collect the data from 24 VFAT3s and to transmit the data optically to the off-detector micro-TCA electronics, as well as to transmit the trigger data at 40 MHz to the CMS Cathode Strip Chamber (CSC) trigger. The microTCA electronics provides the interfaces from the detector (and front-end electronics) to the CMS DAQ, TTC (Timing, Trigger and Control) and Trigger systems. In this paper, we will describe the DAQ system of the Triple-GEM project and provide results from the latest test beam campaigns done at CERN.

  9. Micro flame-based detector suite for universal gas sensing.

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, Thomas Warren; Washburn, Cody M.; Moorman, Matthew Wallace; Manley, Robert George; Lewis, Patrick Raymond; Miller, James Edward; Clem, Paul Gilbert; Shelmidine, Gregory J.; Manginell, Ronald Paul; Okandan, Murat

    2005-11-01

    A microflame-based detector suit has been developed for sensing of a broad range of chemical analytes. This detector combines calorimetry, flame ionization detection (FID), nitrogen-phosphorous detection (NPD) and flame photometric detection (FPD) modes into one convenient platform based on a microcombustor. The microcombustor consists in a micromachined microhotplate with a catalyst or low-work function material added to its surface. For the NPD mode a low work function material selectively ionizes chemical analytes; for all other modes a supported catalyst such as platinum/alumina is used. The microcombustor design permits rapid, efficient heating of the deposited film at low power. To perform calorimetric detection of analytes, the change in power required to maintain the resistive microhotplate heater at a constant temperature is measured. For FID and NPD modes, electrodes are placed around the microcombustor flame zone and an electrometer circuit measures the production of ions. For FPD, the flame zone is optically interrogated to search for light emission indicative of deexcitation of flame-produced analyte compounds. The calorimetric and FID modes respond generally to all hydrocarbons, while sulfur compounds only alarm in the calorimetric mode, providing speciation. The NPD mode provides 10,000:1 selectivity of nitrogen and phosphorous compounds over hydrocarbons. The FPD can distinguish between sulfur and phosphorous compounds. Importantly all detection modes can be established on one convenient microcombustor platform, in fact the calorimetric, FID and FPD modes can be achieved simultaneously on only one microcombustor. Therefore, it is possible to make a very universal chemical detector array with as little as two microcombustor elements. A demonstration of the performance of the microcombustor in each of the detection modes is provided herein.

  10. BJT-based detector on high-resistivity silicon with integrated biasing structure

    Science.gov (United States)

    Verzellesi, G.; Batignani, G.; Bettarini, S.; Boscardin, M.; Bosisio, L.; Dalla Betta, G.-F.; Giacomini, G.; Piemonte, C.

    2006-11-01

    A novel method for biasing phototransistor-based radiation detectors on high-resistivity Si is presented, that relies on the integration into the detector base of a pnp transistor acting as a current source. The proposed approach can be extended in a natural way to the biasing of npn detector arrays, allowing different detectors to be biased at the same quiescent current, by connecting all the biasing pnp transistors with a diode-connected reference transistor (integrated onto the same chip), so that they form a current-mirror circuit. Relying on two-dimensional numerical device simulations, several test structures have been designed and fabricated, including single BJT detectors and detector arrays with pnp biasing transistors connected in the current-mirror configuration. The electrical characterization of fabricated structures shows that both single detectors and detector arrays are operational and behave in good agreement with simulations, thus demonstrating the feasibility of the proposed approach.

  11. Effects of tilted angle of Bragg facets on the performance of successive strips based Bragg concave diffraction grating

    Science.gov (United States)

    Du, Bingzheng; Zhu, Jingping; Mao, Yuzheng; Wang, Kai; Chen, Huibing; Hou, Xun

    2018-03-01

    The effects of the tilted angle of facets on the diffraction orders, diffraction spectra, dispersion power, and the neighbor channel crosstalk of successive etching strips based Bragg concave diffraction grating (Bragg-CDG) are studied in this paper. The electric field distribution and diffraction spectra of four Bragg-CDGs with different tilted angles are calculated by numerical simulations. With the reflection condition of Bragg facets constant, the blazing order cannot change with the titled angle. As the tilted angle increases, the number of diffraction orders of Bragg-CDG will decrease, thereby concentrating more energy on the blazing order and improving the uniformity of diffraction spectra. In addition, the dispersion power of Bragg-CDG can be improved and the neighbor channel crosstalk of devices can be reduced by increasing the tilted angle. This work is beneficial to optimize the performance of Bragg-CDG.

  12. Simultaneous quantitative detection of multiple tumor markers with a rapid and sensitive multicolor quantum dots based immunochromatographic test strip.

    Science.gov (United States)

    Wang, Chunying; Hou, Fei; Ma, Yicai

    2015-06-15

    A novel multicolor quantum dots (QDs) based immunochromatographic test strip (ICTS) was developed for simultaneous quantitative detection of multiple tumor markers, by utilizing alpha fetoprotein (AFP) and carcinoembryonic antigen (CEA) as models. The immunosensor could realize simultaneous quantitative detection of tumor markers with only one test line and one control line on the nitrocellulose membrane (NC membrane) due to the introduction of multicolor QDs. In this method, a mixture of mouse anti-AFP McAb and mouse anti-CEA McAb was coated on NC membrane as test line and goat anti-mouse IgG antibody was coated as control line. Anti-AFP McAb-QDs546 conjugates and anti-CEA McAb-QDs620 conjugates were mixed and applied to the conjugate pad. Simultaneous quantitative detection of multiple tumor markers was achieved by detecting the fluorescence intensity of captured QDs labels on test line and control line using a test strip reader. Under the optimum conditions, AFP and CEA could be detected as low as 3 ng/mL and 2 ng/mL in 15 min with a sample volume of 80 μL, and no obvious cross-reactivity was observed. The immunosensor was validated with 130 clinical samples and in which it exhibited high sensitivity (93% for AFP and 87% for CEA) and specificity (94% for AFP and 97% for CEA). The immunosensor also demonstrated high recoveries (87.5-113% for AFP and 90-97.3% for CEA) and low relative standard deviations (RSDs) (2.8-6.2% for AFP and 4.9-9.6% for CEA) when testing spiked human serum. This novel multicolor QDs based ICTS provides an easy and rapid, simultaneous quantitative detecting strategy for point-of-care testing of tumor markers. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Development of a soil detector based on an optical sensor

    Science.gov (United States)

    Zheng, Lihua; Pan, Luan; Li, Minzan; An, Xiaofei

    2008-12-01

    An estimation model of the soil organic matter content has been built based on NIR spectroscopy and a portable soil organic matter detector based on optical sensor is developed. The detector uses a micro processor 89S52 as the Micro Controller Unit (MCU) and consists of an optical system and a control system. The optical system includes a 850nm near-infrared lamp-house, a lamp-house driving-circuit, a Y type optical fiber, a probe, and a photoelectric sensor. The control system includes an amplified circuit, an A/D circuit, a display circuit with LCD, and a storage circuit with USB interface. Firstly the single waveband optical signal from the near-infrared lamp-house is transferred to the surface of the target soil via the incidence fibers. Then the reflected optical signal is collected and transferred to photoelectric sensor, where the optical signal is conveyed to the electrical signal. Subsequently, the obtained electrical signal is processed by 89S52 MCU. Finally, the calculated soil organic matter content is displayed on the LCD and stored in the USB disk. The calibration experiment using the estimation model of the soil organic matter is conducted. The decision coefficient (R2) reaches 0.9839 between the measured data by the soil organic matter sensor and by the laboratory chemistry method.

  14. Development of a microstrip-based neutron detector

    Indian Academy of Sciences (India)

    The detector has an active area of 20 mm × 15 mm and consists of alternate anodes and ... active area to neutrons and recording the position spectrum. The detector shows fairly uniform efficiency ... ventional multiwire proportional counters (MWPC) in terms of resolution and count rate. The performance of the detector can ...

  15. A novel enhanced calibration method for DSSSD detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, Levent; Vogt, Andreas; Reiter, Peter; Birkenbach, Benedikt; Hirsch, Rouven; Seidlitz, Michael; Warr, Nigel [Institut fuer Kernphysik, Universitaet zu Koeln (Germany)

    2016-07-01

    Double-sided silicon strip detectors (DSSSD) are employed for the detection of charged particles in low-energy nuclear physics providing position and energy information for the impinging particle. Intersecting areas of both p- and n-side strips form individual pixel segments allowing for a high detector granularity. However, due to limitation in fabrication and the response of readout electronics, the performance of different channels may vary. In order to achieve best energy information, a calibration of each p- and n-side strip with a very high precision is mandatory. DSSSD responses are analyzed employing energy correlation matrices between adjacent strips in order to determine charge-sharing and energy-loss effects. A novel calibration method is based on the fact that each event is registered simultaneously on the p- and n-side strips. A two-dimensional calibration procedure allows for a significant enhancement of the energy resolution. In this way, the performance of DSSSDs with position-dependent radiation damage is improved clearly by excluding locally damaged detector areas without losing the information of complete p- or n-side strips.

  16. Nickel(II) removal by mixtures of Acorga M5640 and DP8R in pseudo-emulsion based hollow fiber with strip dispersion technology

    OpenAIRE

    González, Roberto; Cerpa Naranjo, Arisbel; Alguacil, Francisco José

    2010-01-01

    This work presents the investigation of Ni(II) extraction from aqueous solution through pseudo-emulsion based hollow fiber strip dispersion (PSEHFSD) containing the mixture 2-hydroxy-5-nonylbenzaldehyde oxime+di(2-ethylhexyl) phosphoric acid/Exxsol D100 as extractant in the form of a pseudo-emulsion with H₂SO₄. The organic and aqueous strip phases are separated when the stirring device is stopped. The permeation of Ni(II) is investigated as a function of various experimental variables: hydrod...

  17. A prototype coordinate detector based on granulated thin-walled drift tubes

    CERN Document Server

    Bazylev, S N; Tikhomirov, V O; Davkov, K I; Gregor, I; Smirnov, S Y; Senger, P; Shutov, A V; Slepnev, I V; Myalkovskiy, V V; Naumann, L; Mouraviev, S V; Zhukov, I A; Peshekhonov, V D; Russakovich, N A; Rufanov, I A; Rembser, C

    2011-01-01

    A prototype detector based on thin-walled segmented tubes has been developed and its parameters have been studied. The detector contains 360 registration channels with a straw diameter of 4 mm. The prototype' granularity is 4 cm(2) and the length of insensitive region due to straw internal elements is less than 5\\% of its full sensitive area. Deterioration of the spatial resolution near these elements is observed for 1.0\\% of the detector sensitive area. The time and spatial parameters of the detector do not differ from those of conventional tracking detectors based on drift tubes. (C) 2011 Published by Elsevier B.V.

  18. Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen.

    Science.gov (United States)

    Liang, Rong-Liang; Deng, Qiao-Ting; Chen, Zhen-Hua; Xu, Xu-Ping; Zhou, Jian-Wei; Liang, Jun-Yu; Dong, Zhi-Ning; Liu, Tian-Cai; Wu, Ying-Song

    2017-10-26

    Quantitative hepatitis B core antigen (anti-HBc) measurements could play an important role in evaluating therapeutic outcomes and optimizing the antiviral therapy of chronic hepatitis B infection. In this study, we have developed a simple and rapid fluorescence point-of-care test based on a lateral flow immunoassay (LFIA) method integrated with Eu (III) chelate microparticles to quantitatively determine anti-HBc concentrations in serum. This assay is based on a direct competitive immunoassay performed on lateral flow test strips with an assay time of 15 min. The Eu (III) chelate microparticle-based LFIA assay could quantitatively detect anti-HBc levels with a limit of detection of 0.31 IU mL -1 , and exhibited a wide linear range (0.63-640 IU mL -1 ). The intra- and inter-assay coefficients of variation for anti-HBc were both less than 10% and a satisfactory dilution test and accuracy were demonstrated. There were no statistically significant differences in sensitivity or specificity in serum samples between the Eu (III) chelate microparticle-based LFIA strips and the Abbott Architect kit. A simple, rapid and effective quantitative detection of anti-HBc was possible using the Eu (III) chelate microparticle-based LFIA strips. The strips will provide diagnostic value for clinical application.

  19. The Panda Strip Asic: Pasta

    Science.gov (United States)

    Lai, A.

    2018-01-01

    PASTA is the 64 channel front-end chip, designed in a 110 nm CMOS technology to read out the strip sensors of the Micro Vertex Detector (MVD) of the PANDA experiment. This chip provides high resolution timestamp and deposited charge information by means of the time-over-threshold technique. Its working principle is based on a predecessor, the TOFPET ASIC, that was designed for medical applications. A general restructuring of the architecture was needed, in order to meet the specific requirements imposed by the physics programme of PANDA, especially in terms of radiation tolerance, spatial constraints, and readout in absence of a first level hardware trigger. The first revision of PASTA is currently under evaluation at the Forschungszentrum Jülich, where a data acquisition system dedicated to the MVD prototypes has been developed. This paper describes the main aspect of the chip design, gives an overview of the data acquisition system used for the verification, and shows the first results regarding the performance of PASTA.

  20. P-Type Silicon Strip Sensors for the Future CMS Tracker

    CERN Document Server

    The Tracker Group of the CMS Collaboration

    2016-01-01

    The upgrade to the High-Luminosity LHC (HL-LHC) is expected to increase the LHC design luminosity by an order of magnitude. This will require silicon tracking detectors with a significantly higher radiation hardness. The CMS Tracker Collaboration has conducted an irradiation and measurement campaign to identify suitable silicon sensor materials and strip designs for the future outer tracker at CMS. Based on these results, the collaboration has chosen to use n-in-p type strip and macro-pixel sensors and focus further investigations on the optimization of that sensor type. This paper describes the main measurement results and conclusions that motivated this decision.

  1. Noise analysis due to strip resistance in the ATLAS SCT silicon strip module

    International Nuclear Information System (INIS)

    Kipnis, I.

    1996-08-01

    The module is made out of four 6 cm x 6 cm single sided Si microstrip detectors. Two detectors are butt glued to form a 12 cm long mechanical unit and strips of the two detectors are electrically connected to form 12 cm long strips. The butt gluing is followed by a back to back attachment. The module in this note is the Rφ module where the electronics is oriented parallel to the strip direction and bonded directly to the strips. This module concept provides the maximum signal-to-noise ratio, particularly when the front-end electronics is placed near the middle rather than at the end. From the noise analysis, it is concluded that the worst-case ΔENC (far-end injection) between end- and center-tapped modules will be 120 to 210 el. rms (9 to 15%) for a non-irradiated detector and 75 to 130 el. rms (5 to 9%) for an irradiated detector, for a metal strip resistance of 10 to 20 Ω/cm

  2. An aptamer based lateral flow strip for on-site rapid detection of ochratoxin A in Astragalus membranaceus.

    Science.gov (United States)

    Zhou, Weilu; Kong, Weijun; Dou, Xiaowen; Zhao, Ming; Ouyang, Zhen; Yang, Meihua

    2016-06-01

    An aptamer based lateral flow strip based on competitive format was developed for on-site rapid detection of ochratoxin A (OTA) in Astragalus membranaceus. Some crucial parameters that might influence the sensitive detection, such as the characterization of the colloidal gold, size and shape of gold nanoparticles (AuNPs), amount of AuNPs-aptamer conjugate, migration rate and the addition amount of methanol, were investigated to provide the optimum assay performance. To perform the test, 1g sample was extracted with 2.5mL of methanol-water (80:20, v/v) and diluted by 4-fold running buffer to eliminate the matrix and methanol interferences. Under optimized conditions, the aptamer-based assay showed a visual limit of detection (LOD) of 1ngmL(-1), and with no significant cross-reactivity with several homologous toxins. The whole detection could be completed within 15min without special equipment because of available visual results. One out of nine A. membranaceus samples was found to be positive of OTA, which was in a good agreement with those obtained from LC-MS/MS analysis. The results demonstrated that the aptamer-based lateral flow assay could be used as a rapid, reliable, cost-effective and robust on-site screening technique for mycotoxins at trace level in complex matrices without special instrumentation. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Development of Web GIS-Based VFSMOD System with Three Modules for Effective Vegetative Filter Strip Design

    Directory of Open Access Journals (Sweden)

    Dong Soo Kong

    2013-08-01

    Full Text Available In recent years, Non-Point Source Pollution has been rising as a significant environmental issue. The sediment-laden water problem is causing serious impacts on river ecosystems not only in South Korea but also in most countries. The vegetative filter strip (VFS has been thought to be one of the most effective methods to reduce the transport of sediment to down-gradient area. However, the effective width of the VFS first needs to be determined before VFS installation in the field. To provide an easy-to-use interface with a scientific VFS modeling engine, the Web GIS-based VFSMOD system was developed in this study. The Web GIS-based VFSMOD uses the UH and VFSM executable programs from the VFSMOD-w model as core engines to simulate rainfall-runoff and sediment trapping. To provide soil information for a point of interest, the Google Map interface to the MapServer soil database system was developed using the Google Map API, Javascript, Perl/CGI, and Oracle DB programming. Three modules of the Web GIS-based VFSMOD system were developed for various VFS designs under single storm, multiple storm, and long-term period scenarios. These modules in the Web GIS-based VFSMOD system were applied to the study watershed in South Korea and these were proven as efficient tools for the VFS design for various purposes.

  4. Joint preprocesser-based detector for cooperative networks with limited hardware processing capability

    KAUST Repository

    Abuzaid, Abdulrahman I.

    2015-02-01

    In this letter, a joint detector for cooperative communication networks is proposed when the destination has limited hardware processing capability. The transmitter sends its symbols with the help of L relays. As the destination has limited hardware, only U out of L signals are processed and the energy of the remaining relays is lost. To solve this problem, a joint preprocessing based detector is proposed. This joint preprocessor based detector operate on the principles of minimizing the symbol error rate (SER). For a realistic assessment, pilot symbol aided channel estimation is incorporated for this proposed detector. From our simulations, it can be observed that our proposed detector achieves the same SER performance as that of the maximum likelihood (ML) detector with all participating relays. Additionally, our detector outperforms selection combining (SC), channel shortening (CS) scheme and reduced-rank techniques when using the same U. Our proposed scheme has low computational complexity.

  5. Research on Stealthy Headphone Detector Based on Geomagnetic Sensor

    Directory of Open Access Journals (Sweden)

    Liu Ya

    2016-01-01

    Full Text Available A kind of stealth headphone detector based on geomagnetic sensor has been developed to deal with the stealth headphones which are small, extremely stealthy and hard to detect. The U.S. PNI geomagnetic sensor is chosen to obtain magnetic field considering the strong magnetic performance of stealth headphones. The earth’s magnetic field at the geomagnetic sensor is eliminated by difference between two geomagnetic sensors, and then weak variations of magnetic field is detected. STM8S103K2 is chosen as the central controlling chip, which is connected to LED, buzzer and LCD 1602. As shown by the experimental results, the probe is not liable to damage by the magnetic field and the developed device has high sensitivity, low False Positive Rate (FAR and satisfactory reliability.

  6. Track based Alignment of the ATLAS Inner Detector Tracking System

    CERN Document Server

    Schieck, J; The ATLAS collaboration

    2011-01-01

    ATLAS is a multipurpose experiment that records the LHC collisions. In order to reconstruct trajectories of charged particle, ATLAS is equipped with a tracking system built using different technologies, silicon planar sensors (pixel and microstrips) and drift‐tube detectors. In order to achieve its scientific goals, the ATLAS tracking system requires to determine accurately its almost 700,000 degrees of freedom. The demanded precision for the alignment of the silicon sensors is below 10 micrometers. This implies to use a large sample of high momentum and isolated tracks. The high level trigger selects and stores those tracks in a calibration stream. Tracks from cosmic trigger during empty LHC bunches are also used as input for the alignment. The implementation of the track based alignment within the ATLAS software unifies different alignment approaches and allows the alignment of all tracking subsystems together. Primary vertexing and beam spot constraints have been implemented, as well as constraints on th...

  7. Noise spectra in balanced optical detectors based on transimpedance amplifiers

    Science.gov (United States)

    Masalov, A. V.; Kuzhamuratov, A.; Lvovsky, A. I.

    2017-11-01

    We present a thorough theoretical analysis and experimental study of the shot and electronic noise spectra of a balanced optical detector based on an operational amplifier connected in a transimpedance scheme. We identify and quantify the primary parameters responsible for the limitations of the circuit, in particular, the bandwidth and shot-to-electronic noise clearance. We find that the shot noise spectrum can be made consistent with the second-order Butterworth filter, while the electronic noise grows linearly with the second power of the frequency. Good agreement between the theory and experiment is observed; however, the capacitances of the operational amplifier input and the photodiodes appear significantly higher than those specified in manufacturers' datasheets. This observation is confirmed by independent tests.

  8. Thermal neutron detectors based on complex oxide crystals

    CERN Document Server

    Ryzhikov, V; Volkov, V; Chernikov, V; Zelenskaya, O

    2002-01-01

    The ways of improvement of spectrometric quality of CWO and GSO crystals have been investigated with the aim of their application in thermal neutron detectors based on radiation capture reactions. The efficiency of the neutron detection by these crystals was measured, and the obtained data were compared with the results for sup 6 LiI(Tl) crystals. It is shown that the use of complex oxide crystals and neutron-absorption filters for spectrometry of thermal and resonance neutrons could be a promising method in combination with computer data processing. Numerical calculations are reported for spectra of gamma-quanta due to radiation capture of the neutrons. To compensate for the gamma-background lines, we used a crystal pair of heavy complex oxides with different sensitivity to neutrons.

  9. Superconducting multiuser detector for 3G base stations

    Energy Technology Data Exchange (ETDEWEB)

    Kidiyarova-Shevchenko, A.Yu; Platov, K. [Department of Microelectronics and Nanoscience, Chalmers University of Technology, Goeteburg (Sweden); Ottosson, Tony; Stroem, Erik [Department of Signal and Systems, Chalmers University of Technology, Goeteburg, (Sweden)

    2002-01-01

    In this paper we discuss the application of rapid single flux quantum (RSFQ) superconducting digital technology for multiuser detection in wideband code division multiple access base stations. The extraordinary speed of the RSFQ circuits allows us to implement one of the most reliable types of multiuser detector, the successive interference canceller (SIC). The RSFQ SIC consists of the partial cross-correlation unit, responsible for the regeneration of the interference at the receiver and linear combinations of the partial cross-correlations using the path gains, and the iterative linear system solver, which removes the interference from the received signal. We expect that the receiver can yield a capacity gain a factor of two greater than that of a conventional receiver. (author)

  10. Fission-fragment detector for DANCE based on thin scintillating films

    Science.gov (United States)

    Rusev, G.; Roman, A. R.; Daum, J. K.; Springs, R. K.; Bond, E. M.; Jandel, M.; Baramsai, B.; Bredeweg, T. A.; Couture, A.; Favalli, A.; Ianakiev, K. D.; Iliev, M. L.; Mosby, S.; Ullmann, J. L.; Walker, C. L.

    2015-12-01

    A fission-fragment detector based on thin scintillating films has been built to serve as a trigger/veto detector in neutron-induced fission measurements at DANCE. The fissile material is surrounded by scintillating films providing 4 π detection of the fission fragments. The scintillation photons were registered with silicon photomultipliers. A measurement of the 235U (n , f) reaction with this detector at DANCE revealed a correct time-of-flight spectrum and provided an estimate for the efficiency of the prototype detector of 11.6(7)%. Design and test measurements with the detector are described.

  11. The ATLAS Inner Detector operation,data quality and tracking performance.

    CERN Document Server

    Stanecka, E; The ATLAS collaboration

    2012-01-01

    The ATLAS Inner Detector comprises silicon and gas based detectors. The Semi-Conductor Tracker (SCT) and the Pixel Detector are the key precision tracking silicon devices in the Inner Detector of the ATLAS experiment at CERN LHC. And the the Transition Radiation Tracker (TRT), the outermost of the three subsystems of the ATLAS Inner Detector is made of thin-walled proportional-mode drift tubes (straws). The Pixel Detector consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. The SCT is a silicon strip detector and is constructed of 4088 silicon detector modules for a total of 6.3 million strips. Each module is designed, constructed and tested to operate as a stand-alone unit, mechanically, electrically, optically and thermally. The SCT silicon micro-strip sensors are processed in the planar p-in-n technology. The signals from the strips are processed in the front-end ASICS ABCD3TA, working in the binary readout mode. The TRT is made...

  12. The Construction of the CMS Tracker Silicon Strip Modules

    CERN Document Server

    Chiorboli, Massimiliano

    2006-01-01

    The procedures followed for the construction of the Silicon Strip Modules to be used in the CMS Tracker Detector are described. The steps of the production chain are described, and the results are given.

  13. Selective alkaline stripping of metal ions after solvent extraction by base-stable 1,2,3-triazolium ionic liquids.

    Science.gov (United States)

    Raiguel, Stijn; Depuydt, Daphne; Vander Hoogerstraete, Tom; Thomas, Joice; Dehaen, Wim; Binnemans, Koen

    2017-04-19

    Novel 1,2,3-triazolium ionic liquids with a high base stability were synthesized for use in solvent extraction of first-row transition elements and rare earths from chloride media. The synthesis of these ionic liquids makes use of a recently reported, metal-free multicomponent reaction that allows full substitution of the 1,2,3-triazolium skeleton. The physical and chemical properties of these ionic liquids are compared with those of a trisubstituted analog. Peralkylation of the 1,2,3-triazolium skeleton leads to ionic liquids with superior properties, such as low viscosity, low solubility in water and higher thermal and base stability. Iodide and thiocyanate ionic liquids with peralkylated cations were applied to the solvent extraction of metal ions, and their stability in alkaline media was exploited in the selective stripping of the metals from the loaded ionic liquid phase by alkaline solutions. EXAFS and Raman spectroscopy were performed to gain insight into the extraction mechanism. The applicability of these extraction systems was demonstrated in separations relevant for the recovery of metals from ores and end-of-life products: Fe(iii)/Cu(ii)/Zn(ii) (copper ores, brass scraps) and Fe(iii)/Nd(iii) (rare earth magnets).

  14. Rapid and quantitative detection of prostate specific antigen with a quantum dot nanobeads-based immunochromatography test strip.

    Science.gov (United States)

    Li, Xue; Li, Wenbin; Yang, Qiuhua; Gong, Xiaoqun; Guo, Weisheng; Dong, Chunhong; Liu, Junqing; Xuan, Lixue; Chang, Jin

    2014-05-14

    Convenient and fast testing using an immunochromatography test strip (ICTS) enables rapid yes/no decisions regarding a disease to be made. However, the fundamental limitations of an ICTS, such as a lack of quantitative and sensitive analysis, severely hampers its application in reliable medical testing for the early detection of cancer. Herein, we overcame these limitations by integrating an ICTS with quantum dot nanobeads (QD nanobeads), which were fabricated by encapsulating QDs within modified poly(tert-butyl acrylate-co-ethyl acrylate-co-methacrylic acid) and served as a robust signal-generating reagent for the ICTS. Prostate specific antigen (PSA) was used as a model analyte to demonstrate the performance of the QD nanobeads-based ICTS platform. Under optimized conditions, the concentration of PSA could be determined within 15 min with high sensitivity and specificity using only 40 μL of sample. The detection limit was enhanced by ∼12-fold compared with that of an ICTS that used QDs encapsulated by commercial 11-mercaptoundecanoic acid (QDs@MUA) as the signal-generating reagent. At the same time, the possible clinical utility of this approach was demonstrated by measurements recorded from PSA-positive patient specimens. Our data suggest that the QD nanobeads-based ICTS platform is not only rapid and low-cost but also highly sensitive and specific for use in quantitative point-of-care diagnostics; thus, it holds promise for becoming a part of routine medical testing for the early cancer of detection.

  15. Performance of the E771 RPC muon detector at Fermilab

    International Nuclear Information System (INIS)

    Cataldi, G.; Creti, P.; Elia, V.; Fiore, G.; Gorini, E.; Grancagnolo, F.; Panareo, M.; Pinto, C.; Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P.; Corti, G.

    1994-01-01

    The technique of resistive plate counters, equipped with pad readout instead of strips, has been successfully used for the first time in a high rate environment. The performance of the muon detector of E771, based on this technique, is illustrated in detail, including the dependence of the efficiency on the local rate of incident particles. (orig.)

  16. Varicose vein stripping

    Science.gov (United States)

    ... stripping; Venous reflux - vein stripping; Venous ulcer - veins Patient Instructions Surgical wound care - open Varicose veins - what to ask your doctor Images Circulatory system References American Family Physician. Management of varicose veins. www.aafp.org/afp/2008/ ...

  17. Simultaneous Quantitative Detection of Helicobacter Pylori Based on a Rapid and Sensitive Testing Platform using Quantum Dots-Labeled Immunochromatiographic Test Strips

    Science.gov (United States)

    Zheng, Yu; Wang, Kan; Zhang, Jingjing; Qin, Weijian; Yan, Xinyu; Shen, Guangxia; Gao, Guo; Pan, Fei; Cui, Daxiang

    2016-02-01

    Quantum dots-labeled urea-enzyme antibody-based rapid immunochromatographic test strips have been developed as quantitative fluorescence point-of-care tests (POCTs) to detect helicobacter pylori. Presented in this study is a new test strip reader designed to run on tablet personal computers (PCs), which is portable for outdoor detection even without an alternating current (AC) power supply. A Wi-Fi module was integrated into the reader to improve its portability. Patient information was loaded by a barcode scanner, and an application designed to run on tablet PCs was developed to handle the acquired images. A vision algorithm called Kmeans was used for picture processing. Different concentrations of various human blood samples were tested to evaluate the stability and accuracy of the fabricated device. Results demonstrate that the reader can provide an easy, rapid, simultaneous, quantitative detection for helicobacter pylori. The proposed test strip reader has a lighter weight than existing detection readers, and it can run for long durations without an AC power supply, thus verifying that it possesses advantages for outdoor detection. Given its fast detection speed and high accuracy, the proposed reader combined with quantum dots-labeled test strips is suitable for POCTs and owns great potential in applications such as screening patients with infection of helicobacter pylori, etc. in near future.

  18. Commissioning and Calibrating the CMS Silicon Strip Tracker

    CERN Document Server

    Bainbridge, Robert; Drouhin, F; Fulcher, J; Giassi, A; Gross, L; Mirabito, L; Vintache, D; Wingham, M

    2007-01-01

    The data acquisition system for the CMS Silicon Strip Tracker (SST) is based around a custom analogue front-end ASIC, an analogue optical link system and an off-detector VME board that performs digitization, zero-suppression and data formatting. A complex procedure is required to optimally configure, calibrate and synchronize the 107 channels of the SST readout system. We present an overview of this procedure, which will be used to commission and calibrate the SST during the integration, Start-Up and operational phases of the experiment. Recent experiences from the CMS Magnet Test Cosmic Challenge and system tests at the Tracker Integration Facility are also reported.

  19. Laser based stripping system for measurement of the transverse emittance of H-beams at the CERN Linac4

    CERN Document Server

    Hofmann, T; Raich, U; Roncarolo, F; Cheymol, B

    2013-01-01

    The new LINAC4 at CERN will accelerate H- particles to 160 MeV and allow high brightness proton beam transfers to the Proton Synchrotron Booster, via a charge-exchange injection scheme. This paper describes the conceptual design of a laser system proposed for transverse profile and emittance measurements based on photon detachment of electrons from the H- ions. The binding energy of the outer electron is only 0.75 eV and can easily be stripped with a laser beam. Measuring the electron signal as function of the laser position allows the transverse beam profile to be reconstructed. A downstream dipole can also be used to separate the laser neutralized H0 atoms from the main H- beam. By imaging these H0 atoms as a function of laser position the transverse emittance can be reconstructed in the same way as in traditional slit-and-grid systems. By properly dimensioning the laser power and spot size, this method results in negligible beam losses and is therefore non-destructive. In addition, the absence of material ...

  20. Three nonlinear performance relationships in the start-up state of IPMC strips based on finite element analysis

    International Nuclear Information System (INIS)

    Peng, Han Min; Ding, Qing Jun; Hui, Yao; Li, Hua Feng; Zhao, Chun Sheng

    2010-01-01

    Ionic polymer–metal composites (IPMC) are a class of electroactive polymers (EAP), and they currently attract numerous researchers to study their performance characteristics and applications. However, research on its start-up characteristics still requires more attention. In the IPMC start-up state (the moment of applying an actuation voltage at the very beginning), its mechanical performance is different in the stable working state (working for at least 10 min). Therefore, this paper focuses on three performance relationships of an IPMC strip between its maximal tip deformation and voltage, its maximal stress and voltage, as well as its maximal strain and voltage, both in the two states. Different from other reports, we found that they present nonlinear tendencies in the start-up state rather than linear ones. Therefore, based on the equivalent bimorph beam model, a finite element electromechanical coupling calculation module in the ANSYS software was utilized to simulate these characteristics. Furthermore, a test system is introduced to validate the phenomena. As a whole, these three relationships and the FEA method may be beneficial for providing control strategies effectively to IPMC actuators, especially in their start-up states

  1. Development of a Novel Gas Pressurized Stripping Process-Based Technology for CO₂ Capture from Post-Combustion Flue Gases

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Shiaoguo

    2015-09-30

    A novel Gas Pressurized Stripping (GPS) post-combustion carbon capture (PCC) process has been developed by Carbon Capture Scientific, LLC, CONSOL Energy Inc., Nexant Inc., and Western Kentucky University in this bench-scale project. The GPS-based process presents a unique approach that uses a gas pressurized technology for CO₂ stripping at an elevated pressure to overcome the energy use and other disadvantages associated with the benchmark monoethanolamine (MEA) process. The project was aimed at performing laboratory- and bench-scale experiments to prove its technical feasibility and generate process engineering and scale-up data, and conducting a techno-economic analysis (TEA) to demonstrate its energy use and cost competitiveness over the MEA process. To meet project goals and objectives, a combination of experimental work, process simulation, and technical and economic analysis studies were applied. The project conducted individual unit lab-scale tests for major process components, including a first absorption column, a GPS column, a second absorption column, and a flasher. Computer simulations were carried out to study the GPS column behavior under different operating conditions, to optimize the column design and operation, and to optimize the GPS process for an existing and a new power plant. The vapor-liquid equilibrium data under high loading and high temperature for the selected amines were also measured. The thermal and oxidative stability of the selected solvents were also tested experimentally and presented. A bench-scale column-based unit capable of achieving at least 90% CO₂ capture from a nominal 500 SLPM coal-derived flue gas slipstream was designed and built. This integrated, continuous, skid-mounted GPS system was tested using real flue gas from a coal-fired boiler at the National Carbon Capture Center (NCCC). The technical challenges of the GPS technology in stability, corrosion, and foaming of selected solvents, and environmental, health and

  2. The Kalman Filtering Blind Adaptive Multi-user Detector Based on Tracking Algorithm of Signal Subspace

    Directory of Open Access Journals (Sweden)

    Liqing Zhou

    2015-01-01

    Full Text Available Multi-user detection is an effective method to reduce multiple access interference in code division multiple access (CDMA systems. This paper discusses a signal subspace based blind adaptive multiuser detector and a Kalman filtering blind adaptive multiuser detector. Combining them together, a new Kalman filtering blind adaptive multiuser detector based on a tracking algorithm of the signal subspace is proposed. Analysis and simulation show that the proposed blind multiuser detector achieves better suppression of multiple access interference and has a higher convergence rate.

  3. Physics-based generation of gamma-ray response functions for CDZNTE detectors

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Mercer, D.J.; Cooper, C.; Russo, P.A.; Rawool-Sullivan, M.; Close, D.A.; Luke, P.N.; Amman, M.; Soldner, S.

    1997-01-01

    A physics-based approach to gamma-ray response-function generation is presented in which the response of CdZnTe detectors is modeled from first principles. Computer modeling is used to generate response functions needed for spectrum analysis for general detector configurations (e.g., electrode design, detector materials and geometry, and operating conditions). With computer modeling, requirements for calibration and characterization are significantly reduced. Elements of the physics-based model, including gamma-ray transport, charge drift-diffusion, and circuit response, are presented. Calculated and experimental gamma-ray spectra are compared for a coplanar-grid CdZnTe detector

  4. Proposed electronics and data acquisition system for India-based neutrino observatory detector

    International Nuclear Information System (INIS)

    Satyanarayana, B.

    2004-01-01

    Full text : India-based neutrino observatory (INO) collaboration consisting of several Indian Institutions and Universities is currently involved in a feasibility study towards building a neutrino detector in India. We are currently planning for a large and modular detector consisting of 6 cm thick magnetised iron plates interleaved with glass resistive plate chambers (RPCs) used as active detector elements. Good tracking and energy resolution, accurate directionality capability and ease of construction were the parameters which have favoured choice of this type of detector. The main challenges for the design of electronics, trigger and data acquisition include sub-nano second response of the RPCs and huge number of detector channels to handle. These requirements inevitably leads to hardware designs based on high speed VLSI devices and ASICs. We present in this talk, design aspects of these systems for the prototype as well as for the final detectors

  5. Scientific Basis for Paint Stripping Mechanism for Methylene Chloride Based Paint Removers

    Science.gov (United States)

    2011-09-01

    scanning calorimetry EDAX energy dispersive X-ray EM electron microscopy EPA Environmental Protection Agency EPR electron paramagnetic...stability. Aliphatic isocyanates react with another component, polyester polyols , forming the polyurethane topcoat. The polyurethane topcoat also...contains color pigments and silicone dioxide filler. Two-component water borne polyurethane coatings, Class W, are based on an acrylic polyol

  6. BJT detector with FPGA-based read-out for alpha particle monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Tyzhnevyi, V; Dalla Betta, G-F [Universita di Trento, via Sommarive, 14, 38123 Trento (Italy); Rovati, L [Universita di Modena e Reggio Emilia, via Vignolese 905, 41125 Modena (Italy); Verzellesi, G [Universita di Modena e Reggio Emilia, via Amendola 2, Pad. Morselli, 42100 Reggio Emilia (Italy); Zorzi, N, E-mail: tyzhnevyi@disi.unitn.it [Fondazione Bruno Kessler, via Sommarive, 18, 38123 Trento (Italy)

    2011-01-15

    In this work we introduce a new prototype of readout electronics (ALPHADET), which was designed for an {alpha}-particle detection system based on a bipolar junction transistor (BJT) detector. The system uses an FPGA, which provides many advantages at the stage of prototyping and testing the detector. The main design and electrical features of the board are discussed in this paper, along with selected results from the characterization of ALPHADET coupled to BJT detectors.

  7. BJT detector with FPGA-based read-out for alpha particle monitoring

    International Nuclear Information System (INIS)

    Tyzhnevyi, V; Dalla Betta, G-F; Rovati, L; Verzellesi, G; Zorzi, N

    2011-01-01

    In this work we introduce a new prototype of readout electronics (ALPHADET), which was designed for an α-particle detection system based on a bipolar junction transistor (BJT) detector. The system uses an FPGA, which provides many advantages at the stage of prototyping and testing the detector. The main design and electrical features of the board are discussed in this paper, along with selected results from the characterization of ALPHADET coupled to BJT detectors.

  8. Lateral flow strip assay

    Science.gov (United States)

    Miles, Robin R [Danville, CA; Benett, William J [Livermore, CA; Coleman, Matthew A [Oakland, CA; Pearson, Francesca S [Livermore, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2011-03-08

    A lateral flow strip assay apparatus comprising a housing; a lateral flow strip in the housing, the lateral flow strip having a receiving portion; a sample collection unit; and a reagent reservoir. Saliva and/or buccal cells are collected from an individual using the sample collection unit. The sample collection unit is immersed in the reagent reservoir. The tip of the lateral flow strip is immersed in the reservoir and the reagent/sample mixture wicks up into the lateral flow strip to perform the assay.

  9. Properties of GaAs:Cr-based Timepix detectors

    Science.gov (United States)

    Smolyanskiy, P.; Bergmann, B.; Chelkov, G.; Kotov, S.; Kruchonak, U.; Kozhevnikov, D.; Mora Sierra, Y.; Stekl, I.; Zhemchugov, A.

    2018-02-01

    The hybrid pixel detector technology brought to the X-ray imaging a low noise level at a high spatial resolution, thanks to the single photon counting. However, silicon as the most widespread detector material is marginally sensitive to photons with energies above 30 keV. Therefore, the high-Z alternatives to silicon such as gallium arsenide and cadmium telluride are increasingly attracting attention of the community for the development of X-ray imaging systems. The results of our investigations of the Timepix detectors bump bonded to sensors made of gallium arsenide compensated by chromium (GaAs:Cr) are presented in this work. The following properties are most important from the practical point of view: the IV characteristics, the charge transport characteristics, photon detection efficiency, operational stability, homogeneity, temperature dependence, as well as energy and spatial resolution are considered. The applicability of these detectors for spectroscopic X-ray imaging is discussed.

  10. Detectors for Particle Radiation

    Science.gov (United States)

    Kleinknecht, Konrad

    1999-01-01

    This textbook provides a clear, concise and comprehensive review of the physical principles behind the devices used to detect charged particles and gamma rays, and the construction and performance of these many different types of detectors. Detectors for high-energy particles and radiation are used in many areas of science, especially particle physics and nuclear physics experiments, nuclear medicine, cosmic ray measurements, space sciences and geological exploration. This second edition includes all the latest developments in detector technology, including several new chapters covering micro-strip gas chambers, silicion strip detectors and CCDs, scintillating fibers, shower detectors using noble liquid gases, and compensating calorimeters for hadronic showers. This well-illustrated textbook contains examples from the many areas in science in which these detectors are used. It provides both a coursebook for students in physics, and a useful introduction for researchers in other fields.

  11. Gas microstrip detectors based on flexible printed circuit

    International Nuclear Information System (INIS)

    Salomon, M.; Crowe, K.; Faszer, W.; Lindsay, P.; Curran Maier, J.M.

    1995-09-01

    Microstrip Gas Detectors (MSGC's) were introduced some years ago as position sensitive detectors capable of operating at very high rates. The authors have studied the properties of a new type of Gas Microstrip Counter built using flexible printed circuit technology. They describe the manufacturing procedures, the assembly of the device, as well as its operation under a variety of conditions, gases and types of radiation. They also describe two new passivation materials, tantalum and niobium, which produce effective surfaces

  12. Study of relevant parameters of GEM-based detectors

    CERN Document Server

    Croci, Gabriele; Sauli, Fabio; Ragazzi, S

    2007-01-01

    The Gas Electron Multiplier consist of a thin Kapton insulating (50 $\\mu$m) foil copper-clad on both sides and perforated by a high density, regular matrix of holes (around 100 per square millimeter). Typically the distance between holes (pitch) is 140 $\\mu$m and diameters of about 70 $\\mu$m. The mesh is realised by conventional photolitographic methods as used for the fabrication of multi-layer board. Upon application of a potential difference between the GEM electrodes, a high dipole field develops in the holes focusing the field lines between the drift electrode and the readout element. Electron drift along the channel and the charge is amplified by a factor that depends on the field density and the length of the channel. Owing to their excellent position resolution and rate capability GEM-based detector are very suitable to be used in different applications: from the high energy physics to the medical field. The GEM temporal and rate gain stability was studied and it was discovered that the gain variation...

  13. CdTe detector based PIXE mapping of geological samples

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, P.C., E-mail: cchaves@ctn.ist.utl.pt [Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); IST/ITN, Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear, EN10, 2686-953 Sacavém (Portugal); Taborda, A. [Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); IST/ITN, Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear, EN10, 2686-953 Sacavém (Portugal); Oliveira, D.P.S. de [Laboratório Nacional de Energia e Geologia (LNEG), Apartado 7586, 2611-901 Alfragide (Portugal); Reis, M.A. [Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); IST/ITN, Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear, EN10, 2686-953 Sacavém (Portugal)

    2014-01-01

    A sample collected from a borehole drilled approximately 10 km ESE of Bragança, Trás-os-Montes, was analysed by standard and high energy PIXE at both CTN (previous ITN) PIXE setups. The sample is a fine-grained metapyroxenite grading to coarse-grained in the base with disseminated sulphides and fine veinlets of pyrrhotite and pyrite. Matrix composition was obtained at the standard PIXE setup using a 1.25 MeV H{sup +} beam at three different spots. Medium and high Z elemental concentrations were then determined using the DT2fit and DT2simul codes (Reis et al., 2008, 2013 [1,2]), on the spectra obtained in the High Resolution and High Energy (HRHE)-PIXE setup (Chaves et al., 2013 [3]) by irradiation of the sample with a 3.8 MeV proton beam provided by the CTN 3 MV Tandetron accelerator. In this paper we present results, discuss detection limits of the method and the added value of the use of the CdTe detector in this context.

  14. Injection quality measurements with diamond based particle detectors

    CERN Document Server

    Stein, Oliver; CERN. Geneva. ATS Department

    2016-01-01

    During the re-commissioning phase of the LHC after the long shutdown 1 very high beam losses were observed at the TDI during beam injection. The losses reached up to 90% of the dump threshold. To decrease the through beam losses induced stress on the accelerator components these loss levels need to be reduced. Measurements with diamond based particle detectors (dBLMs), which have nano-second time resolution, revealed that the majority of these losses come from recaptured SPS beam surrounding the nominal bunch train. In this MD the injection loss patterns and loss intensities were investigated in greater detail. Performed calibration shots on the TDI (internal beam absorber for injection) gave a conversion factor from impacting particles intensities to signal in the dBLMs (0.1Vs/109 protons). Using the SPS tune kicker for cleaning the recaptured beam in the SPS and changing the LHC injection kicker settings resulted in a reduction of the injection losses. For 144 bunch injections the loss levels were decreased...

  15. Flexible silicon-based alpha-particle detector

    Science.gov (United States)

    Schuster, C. S.; Smith, B. R.; Sanderson, B. J.; Mullins, J. T.; Atkins, J.; Joshi, P.; McNamara, L.; Krauss, T. F.; Jenkins, D. G.

    2017-08-01

    The detection of alpha particles in the field can be challenging due to their short range in air of often only a few centimeters or less. This short range is a particular issue for measuring radiation inside contaminated pipework in the nuclear industry, for which there is currently no simple method available without cutting the pipes open. Here, we propose an approach for low cost, rapid, and safe identification of internally contaminated pipework based on a flexible 30 × 10 mm2 sheet of 50 μm thin crystalline silicon. Following established fabrication steps of pn-junction diodes, we have constructed a device with a signal-to-noise ratio of >20 in response to 5.5 MeV alpha-particles using a bespoke amplifier circuit. As flexible detectors may readily conform to a curved surface and are able to adapt to the curvature of a given pipeline, our prototype device stands out as a viable solution for nuclear decommissioning and related applications.

  16. Millikelvin cryocooler for space- and ground-based detector systems

    Science.gov (United States)

    Bartlett, J.; Hardy, G.; Hepburn, I.; Milward, S.; Coker, P.; Theobald, C.

    2012-09-01

    This paper describes the design of a continuously operating millikelvin cryocooler (mKCC) and its origins. It takes heritage from the double adiabatic demagnetization refrigerator (dADR) which was built for the European Space Agency (ESA). The compact design is based on a tandem configuration continuous ADR which alternately cycles two dADRs. The mKCC is a single module (dimensions 355 x 56 x120 mm) which operates from a 4 K bath (liquid or cryocooler) and provides an interface to the user which is settable from cooling power at 100 mK is 7μW. It will use only single crystal tungsten magnetoresistive heat switches (the first ADR cooler to do so) and the measured thermal performance of these heat switches is presented. The mKCC uses ten shielded 2 Tesla superconducting magnets capable of ramping to full field in 20 - 30 seconds. This has been demonstrated in the lab and the results are given for the successful performance of a prototype Chromium Potassium Alum (CPA) pill using one of these magnets. The mKCC has been designed to be fully automated and user friendly with the aim of expanding the use of millikelvin cryogenics and providing a good testing and operating platform for detector systems.

  17. Low Power Adder Based Digital Filter for QRS Detector

    Directory of Open Access Journals (Sweden)

    L. Murali

    2014-01-01

    Full Text Available Most of the Biomedical applications use dedicated processors for the implementation of complex signal processing. Among them, sensor network is also a type, which has the constraint of low power consumption. Since the processing elements are the most copiously used operations in the signal processors, the power consumption of this has the major impact on the system level application. In this paper, we introduce low power concept of transistor stacking to reduce leakage power; and new architectures based on stacking to implement the full adder and its significance at the digital filter level for QRS detector are implemented. The proposed concept has lesser leakage power at the adder as well as filter level with trade-off in other quality metrics of the design. This enabled the design to be dealt with as the low-power corner and can be made adaptable to any level of hierarchical abstractions as per the requirement of the application. The proposed architectures are designed, modeled at RTL level using the Verilog-HDL, and synthesized in Synopsys Design Compiler by mapping the design to 65 nm technology library standard cells.

  18. New Position Algorithms for the 3-D CZT Drift Detector

    Science.gov (United States)

    Budtz-Jørgensen, C.; Kuvvetli, I.

    2017-06-01

    The 3-D position sensitive CZT detector for high-energy astrophysics developed at DTU has been investigated with a digitizer readout system. The 3-D CZT detector is based on the CZT drift-strip detector principle and was fabricated using a REDLEN CZT crystal (20 mm × 20 mm × 5 mm). The detector contains 12 drift cells, each comprising one collecting anode strip with four drift strips, biased such that the electrons are focused and collected by the anode strips. Three-dimensional position determination is achieved using the anode strip signals, the drift-strip signals, and the signals from ten cathode strips. For the characterization work, we used a DAQ system with a 16 channels 250-MHz 14-b digitizer, SIS3316. It allowed us to analyze the pulse shapes of the signals from four detector cells at a time. The 3-D CZT setup was characterized with a finely collimated radioactive source of 137Cs at 662 keV. The analysis required development of novel position determination algorithms which are the subject of this paper. Using the digitizer readout, we demonstrate improved position determination compared to the previous read out system based on analog electronics. Position resolutions of 0.4-mm full width at half maximum (FWHM) in the x-, y-, and z-directions were achieved and the energy resolution was 7.2-keV FWHM at 662 keV. The timing information allows identification of multiple interaction events within one detector cell, e.g., Compton scattering followed by photoelectric absorption. These characteristics are very important for a high-energy spectral-imager suitable for use in advanced Compton telescopes, or as focal detector for new hard X-ray and soft γ-ray focusing telescopes or in polarimeter instrumentation. CZT detectors are attractive for these applications since they offer relatively high-quantum efficiency. From a technical point of view it is advantageous that their cooling requirements are modest.

  19. The Strip Module

    DEFF Research Database (Denmark)

    Pedersen, Tommy

    1996-01-01

    When the behaviour of a ship in waves is to be predicted it is convenient to have a tool which includes different approaches to the problem.The aim of this project is to develop such a tool named the strip theory module. The strip theory module will consist of submodules dependent on the I....... At last a postprocessor will be included with facilities for statistical calculations and for plots and prints of the results.The project is divided into 7 tasks where the third is to be completed.This report has two aims. To give an introduction to the project of developing a strip theory module......-ship code available at the department. It will be structured as a general preprocessor mainly to determine the hydrodynamic mass and damping. A strip processor including three different theories: A linear frequency domain strip theory, a quadratic strip theory and a nonlinear time domain strip theory...

  20. Evaluation of cassette-based digital radiography detectors using standardized image quality metrics: AAPM TG-150 Draft Image Detector Tests.

    Science.gov (United States)

    Li, Guang; Greene, Travis C; Nishino, Thomas K; Willis, Charles E

    2016-09-08

    The purpose of this study was to evaluate several of the standardized image quality metrics proposed by the American Association of Physics in Medicine (AAPM) Task Group 150. The task group suggested region-of-interest (ROI)-based techniques to measure nonuniformity, minimum signal-to-noise ratio (SNR), number of anomalous pixels, and modulation transfer function (MTF). This study evaluated the effects of ROI size and layout on the image metrics by using four different ROI sets, assessed result uncertainty by repeating measurements, and compared results with two commercially available quality control tools, namely the Carestream DIRECTVIEW Total Quality Tool (TQT) and the GE Healthcare Quality Assurance Process (QAP). Seven Carestream DRX-1C (CsI) detectors on mobile DR systems and four GE FlashPad detectors in radiographic rooms were tested. Images were analyzed using MATLAB software that had been previously validated and reported. Our values for signal and SNR nonuniformity and MTF agree with values published by other investigators. Our results show that ROI size affects nonuniformity and minimum SNR measurements, but not detection of anomalous pixels. Exposure geometry affects all tested image metrics except for the MTF. TG-150 metrics in general agree with the TQT, but agree with the QAP only for local and global signal nonuniformity. The difference in SNR nonuniformity and MTF values between the TG-150 and QAP may be explained by differences in the calculation of noise and acquisition beam quality, respectively. TG-150's SNR nonuniformity metrics are also more sensitive to detector nonuniformity compared to the QAP. Our results suggest that fixed ROI size should be used for consistency because nonuniformity metrics depend on ROI size. Ideally, detector tests should be performed at the exact calibration position. If not feasible, a baseline should be established from the mean of several repeated measurements. Our study indicates that the TG-150 tests can be

  1. A measurement method of a detector response function for monochromatic electrons based on the Compton scattering

    International Nuclear Information System (INIS)

    Bakhlanov, S.V.; Bazlov, N.V.; Derbin, A.V.; Drachnev, I.S.; Kayunov, A.S.; Muratova, V.N.; Semenov, D.A.; Unzhakov, E.V.

    2016-01-01

    In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the scattered photon in the Ge-detector. The novelty of this method is that the source of gamma rays, the germanium and scintillation detectors are immediately arranged adjacent to each other. The method presents an effective solution for the detectors consisting of a low atomic number materials, when the ratio between Compton effect and photoelectric absorption is large and the mean path of gamma-rays is comparable to the size of the detector. The technique can be used for the precision measurements of the scintillator light yield dependence on the electron energy.

  2. CMS Silicon Strip Tracker Performance

    CERN Document Server

    Agram, Jean-Laurent

    2012-01-01

    The CMS Silicon Strip Tracker (SST), consisting of 9.6 million readout channels from 15148 modules and covering an area of 198 square meters, needs to be precisely calibrated in order to correctly reconstruct the events recorded. Calibration constants are derived from different workflows, from promptly reconstructed events with particles as well as from commissioning events gathered just before the acquisition of physics runs. The performance of the SST has been carefully studied since the beginning of data taking: the noise of the detector, data integrity, signal-over-noise ratio, hit reconstruction efficiency and resolution have been all investigated with time and for different conditions. In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

  3. Ammonia stripping of biologically treated liquid manure.

    Science.gov (United States)

    Alitalo, Anni; Kyrö, Aleksis; Aura, Erkki

    2012-01-01

    A prerequisite for efficient ammonia removal in air stripping is that the pH of the liquid to be stripped is sufficiently high. Swine manure pH is usually around 7. At pH 7 (at 20°C), only 0.4% of ammonium is in ammonia form, and it is necessary to raise the pH of swine slurry to achieve efficient ammonia removal. Because manure has a very high buffering capacity, large amounts of chemicals are needed to change the slurry pH. The present study showed that efficient air stripping of manure can be achieved with a small amount of chemicals and without strong bases like NaOH. Slurry was subjected to aerobic biological treatment to raise pH before stripping. This facilitated 8 to 32% ammonia removal without chemical treatment. The slurry was further subjected to repeated cycles of stripping with MgO and Ca(OH)(2) additions after the first and second strippings, respectively, to raise slurry pH in between the stripping cycles. After three consecutive stripping cycles, 59 to 86% of the original ammonium had been removed. It was shown that the reduction in buffer capacity of the slurry was due to ammonia and carbonate removal during the stripping cycles. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  4. An Ultra-Wideband Schottky Diode Based Envelope Detector for 2.5 Gbps signals

    DEFF Research Database (Denmark)

    Cimoli, Bruno; Valdecasa, Guillermo Silva; Granja, Angel Blanco

    2016-01-01

    In this paper an ultra-wideband (UWB) Schottky diode based envelope detector is reported. The detector consists of an input matching network, a Schottky diode and wideband output filtering network. The output network is tailored to demodulate ultra-wideband amplitude shift keying (ASK) signals up...

  5. Muon response in ICAL detector at India-based neutrino observatory

    Indian Academy of Sciences (India)

    Abstract. The magnetized iron calorimeter (ICAL) detector, proposed to be built in the India- based neutrino observatory (INO) laboratory, aims to study atmospheric neutrino oscillations. A simulations study of response of muons to the ICAL detector is presented in the form of momentum reconstruction, angle resolution and ...

  6. Fast neutron fields imaging with a CCD-based luminescent detector

    CERN Document Server

    Mikerov, V

    1999-01-01

    The paper considers some questions concerned with the development of an imaging system based on a CCD-detector for visualising fast neutron fields. From those the most important are: development of fast neutron screens, detector resistance to irradiation fields, and feasibility of fast neutron radiography and tomography at various neutron sources.

  7. Strip-based immunoassay for the simultaneous detection of the neonicotinoid insecticides imidacloprid and thiamethoxam in agricultural products

    Science.gov (United States)

    A semiquantitative strip immunoassay was developed for the rapid detection of imidacloprid and thiamethoxam in agricultural products using specific nanocolloidal gold-labeled monoclonal antibodies. The conjugates of imidacloprid-BSA and thiamethoxam-BSA and goat anti-mouse IgG were coated on the ni...

  8. Online Surface Defect Identification of Cold Rolled Strips Based on Local Binary Pattern and Extreme Learning Machine

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2018-03-01

    Full Text Available In the production of cold-rolled strip, the strip surface may suffer from various defects which need to be detected and identified using an online inspection system. The system is equipped with high-speed and high-resolution cameras to acquire images from the moving strip surface. Features are then extracted from the images and are used as inputs of a pre-trained classifier to identify the type of defect. New types of defect often appear in production. At this point the pre-trained classifier needs to be quickly retrained and deployed in seconds to meet the requirement of the online identification of all defects in the environment of a continuous production line. Therefore, the method for extracting the image features and the training for the classification model should be automated and fast enough, normally within seconds. This paper presents our findings in investigating the computational and classification performance of various feature extraction methods and classification models for the strip surface defect identification. The methods include Scale Invariant Feature Transform (SIFT, Speeded Up Robust Features (SURF and Local Binary Patterns (LBP. The classifiers we have assessed include Back Propagation (BP neural network, Support Vector Machine (SVM and Extreme Learning Machine (ELM. By comparing various combinations of different feature extraction and classification methods, our experiments show that the hybrid method of LBP for feature extraction and ELM for defect classification results in less training and identification time with higher classification accuracy, which satisfied online real-time identification.

  9. Development of a screen-printed carbon electrode based disposable enzyme sensor strip for the measurement of glycated albumin.

    Science.gov (United States)

    Hatada, Mika; Tsugawa, Wakako; Kamio, Eri; Loew, Noya; Klonoff, David C; Sode, Koji

    2017-02-15

    Glycated proteins, such as glycated hemoglobin (HbA1c) or glycated albumin (GA) in the blood, are essential indicators of glycemic control for diabetes mellitus. Since GA, compared to HbA1c, is more sensitive to short term changes in glycemic levels, GA is expected to be used as an alternative or together with HbA1c as a surrogate marker indicator for glycemic control. In this paper we report the development of a sensing system for measuring GA by combining an enzyme analysis method, which is already used in clinical practice, with electrochemical principles. We used fructosyl amino acid oxidase, hexaammineruthenium(III) chloride as the electron mediator, and an inexpensive and economically attractive screen-printed carbon electrode. We used chronoamperometry to measure protease-digested GA samples. The developed sensor strips were able to measure protease-digested samples containing GA in very small sample volumes (1.3μL) within about 1min. We also prepared enzyme sensor strips suitable for clinical use in which the enzyme and the mediator were deposited and dried on. This sensor system showed a clear correlation between the GA concentration and the resulting current. The strips were stable following 3 months of storage at 37°C. We conclude that this disposable enzyme sensor strip system for measuring GA is suitable for point-of-care test (POCT) applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Colorimetric analysis of saliva–alcohol test strips by smartphone-based instruments using machine-learning algorithms

    Science.gov (United States)

    Strip lateral flow assays, similar to a home pregnancy test, are used widely in food safety applications to provide rapid and accurate tests for the presence of specific foodborne pathogens or other contaminants. Though these tests are very rapid, they are not very sensitive, are not quantitative, a...

  11. Large-scale module production for the CMS silicon strip tracker

    CERN Document Server

    Cattai, A

    2005-01-01

    The Silicon Strip Tracker (SST) for the CMS experiment at LHC consists of 210 m**2 of silicon strip detectors grouped into four distinct sub-systems. We present a brief description of the CMS Tracker, the industrialised detector module production methods and the current status of the SST with reference to some problems encountered at the factories and in the construction centres.

  12. An Omnidirectional Polarization Detector Based on a Metamaterial Absorber.

    Science.gov (United States)

    Zhang, Binzhen; Zhang, Yong; Duan, Junping; Zhang, Wendong; Wang, Wanjun

    2016-07-23

    The theory, design, simulation, fabrication, and performance of an omnidirectional polarization detector (PD) with two resonances located in the X and Ka ranges based on a metamaterial absorber (MMA) are presented in this paper. The sandwich structure of PD is composed of 0.1 μm periodic "I" shaped patches on the metasurface, a dielectric of 200 μm FR-4 on the interlayer, and a 0.3 μm copper film on the substrate. PD absorptivity is first used to reflect and describe the polarization of the incident wave. The numerical results, derived from the standard full wave finite integration technology (FIT) of CST 2015, indicates that the designed PD shows polarization sensitivity at all incidence angles. The effects on absorptivity produced by the incidence angles, polarization angles, and materials are investigated. The amplitude of absorptivity change caused by polarization reaches 99.802%. A laser ablation process is adopted to prepare the designed PD on a FR-4 board coated with copper on the double plane with a thickness that was 1/93 and 1/48 of wavelength at a resonance frequency of 16.055 GHz and 30.9 GHz, respectively. The sample test results verify the designed PD excellent detectability on the polarization of the incident waves. The proposed PD, which greatly enriches the applications of metamaterials in bolometers, thermal images, stealth materials, microstructure measurements, and electromagnetic devices, is easy to mass produce and market because of its strong detectability, ultrathin thickness, effective cost, and convenient process.

  13. An Omnidirectional Polarization Detector Based on a Metamaterial Absorber

    Directory of Open Access Journals (Sweden)

    Binzhen Zhang

    2016-07-01

    Full Text Available The theory, design, simulation, fabrication, and performance of an omnidirectional polarization detector (PD with two resonances located in the X and Ka ranges based on a metamaterial absorber (MMA are presented in this paper. The sandwich structure of PD is composed of 0.1 μm periodic “I” shaped patches on the metasurface, a dielectric of 200 μm FR-4 on the interlayer, and a 0.3 μm copper film on the substrate. PD absorptivity is first used to reflect and describe the polarization of the incident wave. The numerical results, derived from the standard full wave finite integration technology (FIT of CST 2015, indicates that the designed PD shows polarization sensitivity at all incidence angles. The effects on absorptivity produced by the incidence angles, polarization angles, and materials are investigated. The amplitude of absorptivity change caused by polarization reaches 99.802%. A laser ablation process is adopted to prepare the designed PD on a FR-4 board coated with copper on the double plane with a thickness that was 1/93 and 1/48 of wavelength at a resonance frequency of 16.055 GHz and 30.9 GHz, respectively. The sample test results verify the designed PD excellent detectability on the polarization of the incident waves. The proposed PD, which greatly enriches the applications of metamaterials in bolometers, thermal images, stealth materials, microstructure measurements, and electromagnetic devices, is easy to mass produce and market because of its strong detectability, ultrathin thickness, effective cost, and convenient process.

  14. dada - a web-based 2D detector analysis tool

    Science.gov (United States)

    Osterhoff, Markus

    2017-06-01

    The data daemon, dada, is a server backend for unified access to 2D pixel detector image data stored with different detectors, file formats and saved with varying naming conventions and folder structures across instruments. Furthermore, dada implements basic pre-processing and analysis routines from pixel binning over azimuthal integration to raster scan processing. Common user interactions with dada are by a web frontend, but all parameters for an analysis are encoded into a Uniform Resource Identifier (URI) which can also be written by hand or scripts for batch processing.

  15. CMS Silicon Strip Tracker Operation and Performance

    CERN Document Server

    Boudoul, Gaelle

    2011-01-01

    The Silicon Strip Tracker (SST) of the CMS experiment is, with 9.6 million readout channels, the largest strip tracker ever built. In order to correctly interpret and reconstruct the events recorded it needs to be precisely calibrated, thus ensuring that it fully contributes to the physics research program of the CMS experiment. In 2009 and 2010, the performance of the SST has been carefully studied using cosmic muons and tracks from proton-proton collisions at centre-of-mass energies of 900 GeV, 2.36 TeV and 7 TeV. In this paper, we present some results of the detector performance.

  16. Performance of a gaseous detector based energy dispersive X-ray fluorescence imaging system: Analysis of human teeth treated with dental amalgam

    Energy Technology Data Exchange (ETDEWEB)

    Silva, A.L.M. [I3N, Physics Dept, University of Aveiro, 3810-193 Aveiro (Portugal); Figueroa, R.; Jaramillo, A. [Physics Department, Universidad de La Frontera, Temuco (Chile); Carvalho, M.L. [Atomic Physics Centre, University of Lisbon, 1649-03 Lisboa (Portugal); Veloso, J.F.C.A., E-mail: joao.veloso@ua.pt [I3N, Physics Dept, University of Aveiro, 3810-193 Aveiro (Portugal)

    2013-08-01

    Energy dispersive X-ray fluorescence (EDXRF) imaging systems are of great interest in many applications of different areas, once they allow us to get images of the spatial elemental distribution in the samples. The detector system used in this study is based on a micro patterned gas detector, named Micro-Hole and Strip Plate. The full field of view system, with an active area of 28 × 28 mm{sup 2} presents some important features for EDXRF imaging applications, such as a position resolution below 125 μm, an intrinsic energy resolution of about 14% full width at half maximum for 5.9 keV X-rays, and a counting rate capability of 0.5 MHz. In this work, analysis of human teeth treated by dental amalgam was performed by using the EDXRF imaging system mentioned above. The goal of the analysis is to evaluate the system capabilities in the biomedical field by measuring the drift of the major constituents of a dental amalgam, Zn and Hg, throughout the tooth structures. The elemental distribution pattern of these elements obtained during the analysis suggests diffusion of these elements from the amalgam to teeth tissues. - Highlights: • Demonstration of an EDXRF imaging system based on a 2D-MHSP detector for biological analysis • Evaluation of the drift of the dental amalgam constituents, throughout the teeth • Observation of Hg diffusion, due to hydroxyapatite crystal defects that compose the teeth tissues.

  17. AIGO: a southern hemisphere detector for the worldwide array of ground-based interferometric gravitational wave detectors

    Energy Technology Data Exchange (ETDEWEB)

    Barriga, P; Blair, D G; Coward, D; Davidson, J; Dumas, J-C; Howell, E; Ju, L; Wen, L; Zhao, C [School of Physics, The University of Western Australia, Crawley, WA 6009 (Australia); McClelland, D E; Scott, S M; Slagmolen, B J J; Inta, R [Department of Physics, Faculty of Science, Australian National University, Canberra, ACT 0200 (Australia); Munch, J; Ottaway, D J; Veitch, P; Hosken, D [Department of Physics, University of Adelaide, Adelaide, SA 5005 (Australia); Melatos, A; Chung, C; Sammut, L, E-mail: pbarriga@cyllene.uwa.edu.a [School of Physics University of Melbourne, Parkville, Vic 3010 (Australia)

    2010-04-21

    This paper describes the proposed AIGO detector for the worldwide array of interferometric gravitational wave detectors. The first part of the paper summarizes the benefits that AIGO provides to the worldwide array of detectors. The second part gives a technical description of the detector, which will follow closely the Advanced LIGO design. Possible technical variations in the design are discussed.

  18. Detectors - Electronics

    International Nuclear Information System (INIS)

    Bregeault, J.; Gabriel, J.L.; Hierle, G.; Lebotlan, P.; Leconte, A.; Lelandais, J.; Mosrin, P.; Munsch, P.; Saur, H.; Tillier, J.

    1998-01-01

    The reports presents the main results obtained in the fields of radiation detectors and associated electronics. In the domain of X-ray gas detectors for the keV range efforts were undertaken to rise the detector efficiency. Multiple gap parallel plate chambers of different types as well as different types of X → e - converters were tested to improve the efficiency (values of 2.4% at 60 KeV were reached). In the field of scintillators a study of new crystals has been carried out (among which Lutetium orthosilicate). CdTe diode strips for obtaining X-ray imaging were studied. The complete study of a linear array of 8 CdTe pixels has been performed and certified. The results are encouraging and point to this method as a satisfying solution. Also, a large dimension programmable chamber was used to study the influence of temperature on the inorganic scintillators in an interval from -40 deg. C to +150 deg. C. Temperature effects on other detectors and electronic circuits were also investigated. In the report mentioned is also the work carried out for the realization of the DEMON neutron multidetector. For neutron halo experiments different large area Si detectors associated with solid and gas position detectors were realized. In the frame of a contract with COGEMA a systematic study of Li doped glasses was undertaken aiming at replacing with a neutron probe the 3 He counters presently utilized in pollution monitoring. An industrial prototype has been realised. Other studies were related to integrated analog chains, materials for Cherenkov detectors, scintillation probes for experiments on fundamental processes, gas position sensitive detectors, etc. In the field of associated electronics there are mentioned the works related to the multidetector INDRA, data acquisition, software gamma spectrometry, automatic gas pressure regulation in detectors, etc

  19. Preliminary results from India-based Neutrino Observatory detector ...

    Indian Academy of Sciences (India)

    We are currently developing and studying the performance of glass RPC prototypes, under the INO detector R & D programme. While we were successful in building and characterising a large number of chambers using local glass, these have met with severe aging problems after a few months of continuous operation.

  20. Amorphous selenium based detectors for medical imaging applications

    Science.gov (United States)

    Mandal, Krishna C.; Kang, Sung H.; Choi, Michael; Jellison, Gerald E., Jr.

    2006-08-01

    We have developed and characterized large volume amorphous (a-) selenium (Se) stabilized alloys for room temperature medical imaging devices and high-energy physics detectors. The synthesis and preparation of well-defined and high quality a-Se (B, As, Cl) alloy materials have been conducted using a specially designed alloying reactor at EIC and installed in an argon atmosphere glove box. The alloy composition has been precisely controlled and optimized to ensure good device performance. The synthesis of large volume boron (B) doped (natural and isotopic 10B) a-Se (As, Cl) alloys has been carried out by thoroughly mixing vacuum distilled and zone-refined (ZR) Se with previously synthesized Se-As master alloys, Se-Cl master alloys and B. The synthesized a-Se (B, As, Cl) alloys have been characterized by x-ray diffraction (XRD), differential scanning calorimetry (DSC), Fourier transform infra-red spectroscopy (FTIR), x-ray photoelectron spectroscopy (XPS), inductively coupled plasma mass spectroscopy (ICP-MS), and detector testing. The a- Se alloys have shown high promise for x-ray detectors with its high dark resistivity (10 10-10 13 Ωcm), good charge transport properties, and cost-effective large area scalability. Details of various steps about detector fabrication and testing of these imaging devices are also presented.

  1. Preliminary results from India-based Neutrino Observatory detector ...

    Indian Academy of Sciences (India)

    area 120 × 90 cm were developed, using float glass procured from the local market. The voltage–current characteristics of these detectors were studied. The noise .... Remote control and monitoring: The required flow rates of individual gases in the system can be set and monitored through a PC interface. Other important.

  2. A task-based evaluation of PEM detector element size.

    Science.gov (United States)

    Raylman, Raymond R; Smith, Mark F

    2006-01-01

    Positron Emission Mammography (PEM) is a planar imaging method that utilizes arrays of discrete detector elements for the detection of radiotracer-avid breast cancer. In this investigation we have systematically studied, through computer simulations, the effect of detector element size (width and length) on breast lesion detection and localization tasks. The contrast-to-noise ratios of the spheres simulating breast lesions were calculated as a function of detector element dimension to gauge detectability. System resolution (fwhm) across the field-of-view was used as the metric for the localization task. For both tasks, individual detector elements of lyso with cross sectional dimensions of 2x2 mm (96x72 element arrays, step 2.1mm) and 3x3mm (65x49 element arrays, step 3.1 mm), and lengths of 10,15 and 20 mm were simulated. The results revealed that narrower pixel dimensions reduced the partial volume effect, while the thicker pixels increased pixel sensitivity, thus reducing noise per pixel and increasing the contrast-to-noise ratio.

  3. New liquid scintillators for detectors based on capillary fibers

    International Nuclear Information System (INIS)

    Vasil'chenko, V.G.; Golovkin, S.V.; Zimin, K.V.

    1997-01-01

    Results of investigations of luminescent and optical characteristics of liquid scintillators intended for using in track detectors and calorimeters are presented. The scintillation efficiency of the vacuumed scintillators is by 22-32% higher than in air. Capillaries filled by liquid scintillators are compared with plastic fibers. 19 refs

  4. Particle detectors based on InP Schottky diodes

    Czech Academy of Sciences Publication Activity Database

    Yatskiv, Roman; Grym, Jan

    2012-01-01

    Roč. 10, č. 7 (2012), C100051-C100055 ISSN 1748-0221 R&D Projects: GA MŠk(CZ) OC10021; GA MŠk LD12014 Institutional support: RVO:67985882 Keywords : Particle detector * High purity InP layer * Schottky diode Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.869, year: 2011

  5. Implementing a Java Based GUI for RICH Detector Analysis

    Science.gov (United States)

    Lendacky, Andrew; Voloshin, Andrew; Benmokhtar, Fatiha

    2016-09-01

    The CLAS12 detector at Thomas Jefferson National Accelerator Facility (TJNAF) is undergoing an upgrade. One of the improvements is the addition of a Ring Imaging Cherenkov (RICH) detector to improve particle identification in the 3-8 GeV/c momentum range. Approximately 400 multi anode photomultiplier tubes (MAPMTs) are going to be used to detect Cherenkov Radiation in the single photoelectron spectra (SPS). The SPS of each pixel of all MAPMTs have been fitted to a mathematical model of roughly 45 parameters for 4 HVs, 3 OD. Out of those parameters, 9 can be used to evaluate the PMTs performance and placement in the detector. To help analyze data when the RICH is operational, a GUI application was written in Java using Swing and detector packages from TJNAF. To store and retrieve the data, a MySQL database program was written in Java using the JDBC package. Using the database, the GUI pulls the values and produces histograms and graphs for a selected PMT at a specific HV and OD. The GUI will allow researchers to easily view a PMT's performance and efficiency to help with data analysis and ring reconstruction when the RICH is finished.

  6. Development of a blood pressure alarm detector based on seven ...

    African Journals Online (AJOL)

    This paper introduces the development of a blood pressure alarm detector, meant to be incorporated into an electronic blood pressure tracking unit, from which it detects signals for the measured blood pressure (BP), that is, the systolic blood pressure (SBP) and diastolic blood pressure (DBP). It simultaneously displays the ...

  7. Application of pseudo-emulsion-based hollow fiber strip dispersion for the extraction of p-nitrophenol from aqueous solutions.

    Science.gov (United States)

    Naidu, Gedela Ashok Kumar; Gupta, Smita; Chakraborty, Mousumi

    2016-11-01

    The extraction of p-nitrophenol (PNP) from aqueous solutions through a pseudo-emulsion hollow fiber strip dispersion (PEHFSD) system was conducted in a microporous hydrophobic polypropylene hollow fiber membrane contactor. For the optimization of the process variables, face-centered central composite design (FCCD) has been used. It was observed that initial feed concentration, carrier composition and stripping phase concentration were the three FCCD factors, which influenced the nitrophenol extraction. Using the optimized process conditions for the separation of PNP, experiments were also performed for the separation of other nitrophenols through PEHFSD system. By the FCCD design and analysis, almost 99% extraction of all three nitrophenols was achieved at optimum conditions. A mass transfer model was also developed and aqueous and membrane resistances were evaluated as 196.46 s cm(-1) and 50.14 s cm(-1), respectively.

  8. Semiconductor detectors with proximity signal readout

    International Nuclear Information System (INIS)

    Asztalos, Stephen J.

    2012-01-01

    Semiconductor-based radiation detectors are routinely used for the detection, imaging, and spectroscopy of x-rays, gamma rays, and charged particles for applications in the areas of nuclear and medical physics, astrophysics, environmental remediation, nuclear nonproliferation, and homeland security. Detectors used for imaging and particle tracking are more complex in that they typically must also measure the location of the radiation interaction in addition to the deposited energy. In such detectors, the position measurement is often achieved by dividing or segmenting the electrodes into many strips or pixels and then reading out the signals from all of the electrode segments. Fine electrode segmentation is problematic for many of the standard semiconductor detector technologies. Clearly there is a need for a semiconductor-based radiation detector technology that can achieve fine position resolution while maintaining the excellent energy resolution intrinsic to semiconductor detectors, can be fabricated through simple processes, does not require complex electrical interconnections to the detector, and can reduce the number of required channels of readout electronics. Proximity electrode signal readout (PESR), in which the electrodes are not in physical contact with the detector surface, satisfies this need

  9. Pulse filtering and correction for CZT detectors using simple digital algorithms based on the wavelet transform

    International Nuclear Information System (INIS)

    Perez, J.M.; Garcia-Belmonte, G.

    1998-01-01

    The authors report an approach to double gaussian filtering used in classical works as dual parameter pulse processing. This technique has been implemented by creating a bank of gaussian-like digital filters based on wavelet transforms. A simple method to correct for the charge loss inherent to room temperature semiconductor gamma detectors has been developed. This method is based on multi-resolution signal analysis. Results are reported from tests of these algorithms on commercial CZT detectors and two trapped hole charge correction levels are compared. Finally, the advantages and limitations of this new approach to detector pulse processing are discussed

  10. Long-distance transmission of light in a scintillator-based radiation detector

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, Jonathan L.; Talbott, Dale V.; Hehlen, Markus P.

    2017-07-11

    Scintillator-based radiation detectors capable of transmitting light indicating the presence of radiation for long distances are disclosed herein. A radiation detector can include a scintillator layer and a light-guide layer. The scintillator layer is configured to produce light upon receiving incident radiation. The light-guide layer is configured to receive light produced by the scintillator layer and either propagate the received light through the radiation detector or absorb the received light and emit light, through fluorescence, that is propagated through the radiation detector. A radiation detector can also include an outer layer partially surrounding the scintillator layer and light-guide layer. The index of refraction of the light-guide layer can be greater than the index of refraction of adjacent layers.

  11. Aging measurements on triple-GEM detectors operated with $CF_{4}$-based gas mixtures

    CERN Document Server

    Alfonsi, M; De Simone, P; Murtas, F; Poli Lener, M P; Bonivento, W; Cardini, A; Raspino, D; Saitta, B; Pinci, D; Baccaro, S; 10.1016/j.nuclphysbps.2005.03.054

    2006-01-01

    We present the results of a global irradiation test of full size triple-GEM detectors operated with CF/sub 4/-based gas mixtures. This study has been performed in the framework of an R&D activity on detectors for the innermost region of the first muon station of the LHCb experiment. The prototypes have been irradiated at the Calliope facility of the ENEA-Casaccia with a high intensity 1.25 MeV detectors performances have been measured with X-rays and with a 3 Ge V pion beam at CERN. A SEM analysis on several samples of the detectors has been performed to complete the understanding of the physical processes occurring in a GEM detector during a strong irradiation.

  12. Aging measurements on triple-GEM detectors operated with $CF_{4}$- based gas mixtures

    CERN Document Server

    Alfonsi, M; Bencivenni, G; Bonivento, W; Cardini, A; Lener, M P; Murtas, F; Pinci, D; Raspino, D; Saitta, B; De Simone, P

    2004-01-01

    We present the results of a global irradiation test of full size triple-GEM detectors operated with CF/sub 4/-based gas mixtures. This study has been performed in the framework of an R&D activity on detectors for the innermost region of the first muon station of the LHCb experiment. The prototypes have been irradiated at the Calliope facility of the ENEA-Casaccia with a high intensity 1.25 MeV gamma from a /sup 60/Co source. After the irradiation test the detectors performances have been measured with X-rays and with a 3 GeV pion beam at CERN. A SEM analysis on several samples of the detectors has been performed to complete the understanding of the physical processes occurring in the GEM detector during the strong irradiation.

  13. Monolithic integration of high-speed Ge photo-detectors on SOI-based WDM receivers

    Science.gov (United States)

    Qian, Wei; Feng, Dazeng; Liang, Hong; Zhou, Joe; Liu, Yong; Liao, Shirong; Kung, Cheng-Chih; Fong, Joan; Luff, B. Jonathan; Shafiiha, Roshanak; Lee, Daniel; White, Wayne; Asghari, Mehdi

    2012-06-01

    We report a novel, compact design of high speed Ge photo detector integrated with an echelle demultiplexer on a large cross-section SOI platform with low insertion loss and low fiber coupling loss. A narrow Ge photo detector waveguide is directly butt-coupled to a Si waveguide to ensure low loss and high speed operation. With a Ge detector size of only 0.8×15 μm2, the device achieves greater than 30 GHz modulation speed. The results indicate that the device speed is transit time limited and that the detector performance benefits from the high electron and hole drift velocity of germanium. The dark current of the detector is less than 0.5μA at -1V. This small footprint high speed Si-based WDM receiver can be fabricated using CMOS processes and used for multichannel terabit data transmission with low manufacturing cost.

  14. Aging measurements on triple-GEM detectors operated with CF{sub 4}-based gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Alfonsi, M. [Laboratori Nazionali di Frascati - INFN, Frascati (Italy); Bencivenni, G. [Laboratori Nazionali di Frascati - INFN, Frascati (Italy); De Simone, P. [Laboratori Nazionali di Frascati - INFN, Frascati (Italy); Murtas, F. [Laboratori Nazionali di Frascati - INFN, Frascati (Italy); Poli Lener, M. [Laboratori Nazionali di Frascati - INFN, Frascati (Italy); Bonivento, W. [Sezione INFN di Cagliari, Cagliari (Italy); Cardini, A. [Sezione INFN di Cagliari, Cagliari (Italy); Raspino, D. [Sezione INFN di Cagliari, Cagliari (Italy); Saitta, B. [Sezione INFN di Cagliari, Cagliari (Italy); Pinci, D. [Sezione INFN di Roma 1, Rome (Italy); Baccaro, S. [ENEA-FIS/ION, C.R. Casaccia, 00060, S. Maria di Galeria (Rome) (Italy)

    2006-01-15

    We present the results of a global irradiation test of full size triple-GEM detectors operated with CF{sub 4}-based gas mixtures. This study has been performed in the framework of an R and D activity on detectors for the innermost region of the first muon station of the LHCb experiment. The prototypes have been irradiated at the Calliope facility of the ENEA-Casaccia with a high intensity 1.25 MeV {gamma} {sup 6}Co source. After the irradiation test the detectors performances have been measured with X-rays and with a 3 GeV pion beam at CERN. A SEM analysis on several samples of the detectors has been performed to complete the understanding of the physical processes occurring in a GEM detector during a strong irradiation.

  15. An InGrid based Low Energy X-ray Detector

    CERN Document Server

    Krieger, Christoph; Kaminski, Jochen; Lupberger, Michael; Vafeiadis, Theodoros

    2014-01-01

    An X-ray detector based on the combination of an integrated Micromegas stage with a pixel chip has been built in order to be installed at the CERN Axion Solar Telescope. Due to its high granularity and spatial resolution this detector allows for a topological background suppression along with a detection threshold below $1\\,\\text{keV}$. Tests at the CAST Detector Lab show the detector's ability to detect X-ray photons down to an energy as low as $277\\,\\text{eV}$. The first background data taken after the installation at the CAST experiment underline the detector's performance with an average background rate of $5\\times10^{-5}\\,/\\text{keV}/\\text{cm}^2/\\text{s}$ between 2 and $10\\,\\text{keV}$ when using a lead shielding.

  16. Silicon detector technology development in India for the participation ...

    Indian Academy of Sciences (India)

    A specific research and development program has been carried out by BARC in India to develop the technology for large area silicon strip detectors for application in nuclear and high energy physics experiments. These strip detectors will be used as pre-shower detector in the CMS experiment at LHC, CERN for 0/ ...

  17. Silicon detector technology development in India for the participation ...

    Indian Academy of Sciences (India)

    Abstract. A specific research and development program has been carried out by BARC in India to develop the technology for large area silicon strip detectors for application in nuclear and high energy physics experiments. These strip detectors will be used as pre-shower detector in the CMS experiment at LHC, CERN for ...

  18. FIR Detectors/Cameras Based on GaN and Si Field-Effect Devices Project

    Data.gov (United States)

    National Aeronautics and Space Administration — SETI proposes to develop GaN and Si based multicolor FIR/THz cameras with detector elements and readout, signal processing electronics integrated on a single chip....

  19. Ultra-Low-Noise Sub-mm/FIR Detectors for Space-based Astrophysics

    Data.gov (United States)

    National Aeronautics and Space Administration — The Ultra-Low-Noise Sub-mm/FIR Detectors for Space-based Astrophysics project develops structures that will improve the control of the thermal conductance in...

  20. Cephalaria transsylvanica-Based Flower Strips as Potential Food Source for Bees during Dry Periods in European Mediterranean Basin Countries

    Science.gov (United States)

    Benelli, Giovanni; Benvenuti, Stefano; Desneux, Nicolas; Canale, Angelo

    2014-01-01

    The introduction of sown wildflower strips favours the establishment of pollinator communities, with special reference to social Apoidea. Here, we evaluated the late summer flowering Cephalaria transsylvanica as suitable species for strips providing food for pollinators in paucity periods. C. transsylvanica showed no particular requirements in terms of seed germination and growth during summer. This plant had an excellent potential of self-seeding and competitiveness towards weed competitors. C. transsylvanica prevented from entomophilous pollination showed inbreeding depression, with a decrease in seed-set and accumulation of seed energy reserves. However, C. transsylvanica did not appear to be vulnerable in terms of pollination biology since it had a wide range of pollinators including bees, hoverflies and Lepidoptera. C. transsylvanica was visited mainly by honeybees and bumblebees and these latter pollinators increased their visits on C. transsylvanica flowers during early autumn. This plant may be useful as an abundant source of pollen during food paucity periods, such as autumn. We proposed C. transsylvanica for incorporation into flower strips to be planted in non-cropped farmlands in intensively managed agricultural areas as well as in proximity of beehives. The latter option may facilitate the honeybees collecting pollen and nectar for the colony, thereby ensuring robustness to overcome the winter season. PMID:24676345

  1. Large-square coordinate detector based on streamer tubes

    International Nuclear Information System (INIS)

    Aul'chenko, V.M.; Bajbusinov, B.O.; Lel'chuk, M.Yu.; Nomerotskij, A.B.; Chegodaev, A.V.; Chilingarov, A.G.

    1988-01-01

    The KMD-2 and KEDR muon detector system for experiments at VEPP storage rings is described. The KMD-2 muon system includes two layers of streamer tubes separated by the magnet yoke iron. Each layer consists of 8 octant-units. The tubes inside the unit are seriesly connected into batches of 4 for inner units (tube diameter is 20 mm) and into batches of 8 for outer units (tube diameter is 40 mm). The total tube number constitute 656, the chammel number being 128. The KEDR muon sytem for the VEPP-4 stirage ring will consist of 5 thousands of streamer tubes 40 mm in-dameter and 4-5 m long connected into batches of 4 tubes. Flowsheet of electronic channel is presented. One time channel permits to get 12x20 mm spatial resolution at detector square of 40x20000 mm. 3 refs.; 1 fig

  2. Saturated virtual fluorescence emission difference microscopy based on detector array

    Science.gov (United States)

    Liu, Shaocong; Sun, Shiyi; Kuang, Cuifang; Ge, Baoliang; Wang, Wensheng; Liu, Xu

    2017-07-01

    Virtual fluorescence emission difference microscopy (vFED) has been proposed recently to enhance the lateral resolution of confocal microscopy with a detector array, implemented by scanning a doughnut-shaped pattern. Theoretically, the resolution can be enhanced by around 1.3-fold compared with that in confocal microscopy. For further improvement of the resolving ability of vFED, a novel method is presented utilizing fluorescence saturation for super-resolution imaging, which we called saturated virtual fluorescence emission difference microscopy (svFED). With a point detector array, matched solid and hollow point spread functions (PSF) can be obtained by photon reassignment, and the difference results between them can be used to boost the transverse resolution. Results show that the diffraction barrier can be surpassed by at least 34% compared with that in vFED and the resolution is around 2-fold higher than that in confocal microscopy.

  3. CCD readout of GEM-based neutron detectors

    CERN Document Server

    Fraga, F A F; Fetal, S T G; Fraga, M; Guérard, B; Manzini, G; Margato, L M S; Oed, A; Policarpo, Armando; Vuure, T V

    2002-01-01

    We report on the optical readout of the gas electron multiplier (GEM) operated with a gaseous mixture suitable for the detection of thermal neutrons: sup 3 He-CF sub 4. A CCD system operating in the 400-1000 nm band was used to collect the light. Spectroscopic data on the visible and NIR scintillation of He-CF sub 4 are presented. Images of the tracks of the proton and triton recorded with a triple GEM detector are also shown.

  4. Anatomy Comic Strips

    Science.gov (United States)

    Park, Jin Seo; Kim, Dae Hyun; Chung, Min Suk

    2011-01-01

    Comics are powerful visual messages that convey immediate visceral meaning in ways that conventional texts often cannot. This article's authors created comic strips to teach anatomy more interestingly and effectively. Four-frame comic strips were conceptualized from a set of anatomy-related humorous stories gathered from the authors' collective…

  5. Science Comic Strips

    Science.gov (United States)

    Kim, Dae Hyun; Jang, Hae Gwon; Shin, Dong Sun; Kim, Sun-Ja; Yoo, Chang Young; Chung, Min Suk

    2012-01-01

    Science comic strips entitled Dr. Scifun were planned to promote science jobs and studies among professionals (scientists, graduate and undergraduate students) and children. To this end, the authors collected intriguing science stories as the basis of scenarios, and drew four-cut comic strips, first on paper and subsequently as computer files.…

  6. The Micro Wire Detector

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M. E-mail: maximo.plo@cern.ch; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C

    1999-10-11

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 {mu}m{sup 2} apertures, crossed by 25 {mu}m anode strips to which it is attached by 50 {mu}m kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  7. Experimental and theoretical performance analysis for a CMOS-based high resolution image detector

    Science.gov (United States)

    Jain, Amit; Bednarek, Daniel R.; Rudin, Stephen

    2014-03-01

    Increasing complexity of endovascular interventional procedures requires superior x-ray imaging quality. Present stateof- the-art x-ray imaging detectors may not be adequate due to their inherent noise and resolution limitations. With recent developments, CMOS based detectors are presenting an option to fulfill the need for better image quality. For this work, a new CMOS detector has been analyzed experimentally and theoretically in terms of sensitivity, MTF and DQE. The detector (Dexela Model 1207, Perkin-Elmer Co., London, UK) features 14-bit image acquisition, a CsI phosphor, 75 μm pixels and an active area of 12 cm x 7 cm with over 30 fps frame rate. This detector has two modes of operations with two different full-well capacities: high and low sensitivity. The sensitivity and instrumentation noise equivalent exposure (INEE) were calculated for both modes. The detector modulation-transfer function (MTF), noise-power spectra (NPS) and detective quantum efficiency (DQE) were measured using an RQA5 spectrum. For the theoretical performance evaluation, a linear cascade model with an added aliasing stage was used. The detector showed excellent linearity in both modes. The sensitivity and the INEE of the detector were found to be 31.55 DN/μR and 0.55 μR in high sensitivity mode, while they were 9.87 DN/μR and 2.77 μR in low sensitivity mode. The theoretical and experimental values for the MTF and DQE showed close agreement with good DQE even at fluoroscopic exposure levels. In summary, the Dexela detector's imaging performance in terms of sensitivity, linear system metrics, and INEE demonstrates that it can overcome the noise and resolution limitations of present state-of-the-art x-ray detectors.

  8. Reproducibility and calibration of MMC-based high-resolution gamma detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bates, C. R.; Friedrich, S., E-mail: friedrich1@llnl.gov [Lawrence Livermore National Laboratory, 7000 East Ave., Livermore, California 94550 (United States); Pies, C.; Kempf, S.; Hengstler, D.; Fleischmann, A.; Gastaldo, L.; Enss, C. [Kirchhoff-Institut für Physik, Universität Heidelberg, Im Neuenheimer Feld 227, D-69120 Heidelberg (Germany)

    2016-07-11

    We describe a prototype γ-ray detector based on a metallic magnetic calorimeter with an energy resolution of 46 eV at 60 keV and a reproducible response function that follows a simple second-order polynomial. The simple detector calibration allows adding high-resolution spectra from different pixels and different cool-downs without loss in energy resolution to determine γ-ray centroids with high accuracy. As an example of an application in nuclear safeguards enabled by such a γ-ray detector, we discuss the non-destructive assay of {sup 242}Pu in a mixed-isotope Pu sample.

  9. Combined detectors of charged particles based on zinc selenide scintillators and silicon photodiodes

    CERN Document Server

    Ryzhikov, V D; Starzhinskij, N G

    2001-01-01

    combined detectors of charged particles are described based on zinc selenide (Zn Se(Te)) crystals,silicon photodiodes and charges-sensitive amplifiers. Zn Se(Te) scintillators are characterized by high alpha to beta ratio (approx 1.0), good scintillation efficiency (up to 22%),and high radiation stability (up to 100 Mrad),together with good spectral matching with silicon PIN photodiodes. The signal coming from the photodiode in the two modes (photoreceiver and semiconductor detector) differ in the amplitude values and pulse duration, which opens new possibilities for development and application of such combined detectors.

  10. SIRI - A proposal for a multi-detector ΔE-E particle telescope

    International Nuclear Information System (INIS)

    Guttormsen, M.

    1992-06-01

    The CACTUS detector system which is mounted on the 90 o beam line of the Oslo Cyclotron consists of 28 NaI and 2 Ge detectors in combination with 8 Si particle telescopes. The Si particle telescopes are however based on an old technology with a geometrical lay-out that prohibits further increase in efficiency. In this report a replacement of the old system in the form of 64 telescopes based on silicon strip detectors is proposed. For the planned system called SIRI (Silicon Ring), the detectors are located on a ring around the target, covering the angles between 30 o and 60 o relative to the beam direction. The planned detector system will increase detector efficiency of charged particles by a factor 8. The design and construction of the new detector system is described and discussed. 8 refs., 9 figs., 4 tabs

  11. Design, implementation and testing of SRAM based neutron detectors

    OpenAIRE

    Velure, Arild

    2011-01-01

    Neutrons of thermal and high energies can change the value of a bit stored in a Static Random Access Memory (SRAM) memory chip. The effect is non destructive and linearly dependent on the amount of incoming particles, which makes it exploitable for use as a neutron detector. Detection is done by writing a known pattern to the memory and continuously reading it back checking for wrong values. As the SRAM memory is immune to gamma radiation it is ideal for use in for instance medical linear acc...

  12. Smartphone based point-of-care detector of urine albumin

    Science.gov (United States)

    Cmiel, Vratislav; Svoboda, Ondrej; Koscova, Pavlina; Provaznik, Ivo

    2016-03-01

    Albumin plays an important role in human body. Its changed level in urine may indicate serious kidney disorders. We present a new point-of-care solution for sensitive detection of urine albumin - the miniature optical adapter for iPhone with in-built optical filters and a sample slot. The adapter exploits smart-phone flash to generate excitation light and camera to measure the level of emitted light. Albumin Blue 580 is used as albumin reagent. The proposed light-weight adapter can be produced at low cost using a 3D printer. Thus, the miniaturized detector is easy to use out of lab.

  13. The 'KATOD-1' strip readout ASIC for cathode strip chamber

    International Nuclear Information System (INIS)

    Golutvin, I.A.; Gorbunov, N.V.; Karzhavin, V.Yu.; Khabarov, V.S.; Movchan, S.A.; Smolin, D.A.; Dvornikov, O.V.; Shumejko, N.M.; Chekhovskij, V.A.

    2001-01-01

    The 'KATOD-1', a 16-channels readout ASIC, has been designed to perform tests of P3 and P4 full-scale prototypes of the cathode strip chamber for the ME1/1 forward muon station of the Compact Muon Solenoid (CMS) experiment. The ASIC channel consists of two charge-sensitive preamplifiers, a three-stage shaper with cancellation, and an output driver. The ASIC is instrumented with control of gain, in the range of (-4.2 : +5.0) mV/fC, and control of output pulse-shape. The equivalent input noise is equal to 2400 e with the slope of 12 e/pF for detector capacity up to 200 pF. The peaking time is 100 ns for the chamber signal. The ASIC has been produced by a microwave Bi-jFET technology

  14. High dynamic range CMOS-based mammography detector for FFDM and DBT

    Science.gov (United States)

    Peters, Inge M.; Smit, Chiel; Miller, James J.; Lomako, Andrey

    2016-03-01

    Digital Breast Tomosynthesis (DBT) requires excellent image quality in a dynamic mode at very low dose levels while Full Field Digital Mammography (FFDM) is a static imaging modality that requires high saturation dose levels. These opposing requirements can only be met by a dynamic detector with a high dynamic range. This paper will discuss a wafer-scale CMOS-based mammography detector with 49.5 μm pixels and a CsI scintillator. Excellent image quality is obtained for FFDM as well as DBT applications, comparing favorably with a-Se detectors that dominate the X-ray mammography market today. The typical dynamic range of a mammography detector is not high enough to accommodate both the low noise and the high saturation dose requirements for DBT and FFDM applications, respectively. An approach based on gain switching does not provide the signal-to-noise benefits in the low-dose DBT conditions. The solution to this is to add frame summing functionality to the detector. In one X-ray pulse several image frames will be acquired and summed. The requirements to implement this into a detector are low noise levels, high frame rates and low lag performance, all of which are unique characteristics of CMOS detectors. Results are presented to prove that excellent image quality is achieved, using a single detector for both DBT as well as FFDM dose conditions. This method of frame summing gave the opportunity to optimize the detector noise and saturation level for DBT applications, to achieve high DQE level at low dose, without compromising the FFDM performance.

  15. Development of a reader for track etch detectors based on a commercially available slide scanner

    CERN Document Server

    Steele, J D; Tanner, R J; Bartlett, D T

    1999-01-01

    NRPB has operated a routine neutron personal dosimetry service based on the electrochemical etch of PADC elements since 1986. Since its inception it has used an automated reader based on a video camera and real time analysis. A new and more powerful replacement system has been developed using a commercially available photographic slide scanner. This permits a complete image of the dosemeter to be grabbed in a single scan, generating a 2592x3888 pixel file which is saved for subsequent analysis. This gives an effective pixel size of 10x10 mu m with an image of the entire dosemeter in one field of view. Custom written software subsequently analyses the image to assess the number of etched pits on the dosemeter and read the detector identification number (code). Batch scanning of up to 40 detectors is also possible using an autofeed attachment. The system can be used for electrochemically etched tracks for neutron detectors and chemically etched tracks for radon detectors.

  16. Progress in the development of a S RETGEM-based detector for an early forest fire warning system

    CERN Document Server

    Charpak, Georges; Breuil, P; Martinengo, P; Nappi, E; Peskov, V

    2009-01-01

    In this paper we present a prototype of a Strip Resistive Thick GEM photosensitive gaseous detector filled with Ne and ethylferrocene vapours at a total pressure of 1 atm for an early forest fire detection system. Tests show that it is one hundred times more sensitive than the best commercial ultraviolet flame detectors and therefore, it is able to reliably detect a flame of 1.5x1.5x1.5 m3 at a distance of about 1km. An additional and unique feature of this detector is its imaging capability, which in combination with other techniques, may significantly reduce false fire alarms when operating in an automatic mode. Preliminary results conducted with air filled photosensitive gaseous detectors are also presented. The approach main advantages include both the simplicity of manufacturing and affordability of construction materials such as plastics and glues specifically reducing detector production cost. The sensitivity of these air filled detectors at certain conditions may be as high as those filled with Ne and...

  17. Strip defect recognition in electrical tests of silicon microstrip sensors

    Energy Technology Data Exchange (ETDEWEB)

    Valentan, Manfred, E-mail: valentan@mpp.mpg.de

    2017-02-11

    This contribution describes the measurement procedure and data analysis of AC-coupled double-sided silicon microstrip sensors with polysilicon resistor biasing. The most thorough test of a strip sensor is an electrical measurement of all strips of the sensor; the measured observables include e.g. the strip's current and the coupling capacitance. These measurements are performed to find defective strips, e.g. broken capacitors (pinholes) or implant shorts between two adjacent strips. When a strip has a defect, its observables will show a deviation from the “typical value”. To recognize and quantify certain defects, it is necessary to determine these typical values, i.e. the values the observables would have without the defect. As a novel approach, local least-median-of-squares linear fits are applied to determine these “would-be” values of the observables. A least-median-of-squares fit is robust against outliers, i.e. it ignores the observable values of defective strips. Knowing the typical values allows to recognize, distinguish and quantify a whole range of strip defects. This contribution explains how the various defects appear in the data and in which order the defects can be recognized. The method has been used to find strip defects on 30 double-sided trapezoidal microstrip sensors for the Belle II Silicon Vertex Detector, which have been measured at the Institute of High Energy Physics, Vienna (Austria).

  18. Paediatric emergency department-based carbon monoxide detector intervention: a randomised trial.

    Science.gov (United States)

    McKenzie, Lara B; Roberts, Kristin J; Kaercher, Roxanne M; Collins, Christy L; Comstock, R Dawn; Fernandez, Soledad; Abdel-Rasoul, Mahmoud; Casavant, Marcel J; Mihalov, Leslie

    2017-10-01

    Although non-fire-related carbon monoxide (CO) poisoning is almost entirely preventable, over 400 people die and 20 000 people are injured each year in the USA from unintentional CO poisoning. Thus, there is a critical need for evidence-based interventions for preventing CO poisoning and increasing the proper use and installation of CO detectors. A randomised, controlled trial (Project CODE, a Carbon Monoxide Detector Education intervention) with 2-week and 6-month follow-up home observations was conducted in 299 parents of children aged ≤18 years recruited in the emergency department of a level 1 paediatric trauma centre. The intervention group received an educational tool, a spiral-bound, laminated booklet that resembled a CO detector containing theory-based safety messages based on the precaution adoption process model, a plug-in CO detector and 9 V battery. The control group received a one page flyer on CO poisoning prevention. Although the difference was not statistically significant, mean CO knowledge score increased at a greater rate for the intervention group than the control group. Intervention group parents were more likely to exhibit 'safe' CO detector use than control group parents at the 2-week follow-up (RR: 2.75; 95% CI 2.06 to 3.69) and 6-month follow-up (RR: 2.78; 95% CI 2.06 to 3.76), after adjusting for self-reported CO detector use behaviour at enrolment and annual per capita income. An emergency department-delivered intervention containing a theory-based educational tool paired with a CO detector can be an effective method for increasing knowledge about CO poisoning, for prevention and for appropriate use of a CO detector. NCT00959478. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Quantum Engineering of States in Heterostructure-based Detectors for Enhance Performance

    Science.gov (United States)

    2017-05-26

    each year. This is UIC’s highest teaching award. Elected to the College of Fellows, American Institute of Medical and Biomedical Engineers ...AFRL-AFOSR-VA-TR-2017-0109 Quantum engineering of heterostructure detectors for enhanced performance Michael Stroscio UNIVERSITY OF ILLINOIS Final...SUBTITLE Quantum Engineering of States in Heterostructure-based Detectors for Enhance Performance 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA9550-15-1

  20. TORCH-a Cherenkov based time-of-flight detector

    Science.gov (United States)

    van Dijk, M. W. U.; Brook, N. H.; Castillo García, L.; Cowie, E. N.; Cussans, D.; D`Ambrosio, C.; Fopma, J.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Harnew, N.; Keri, T.; Piedigrossi, D.

    2014-12-01

    TORCH is an innovative high-precision time-of-flight system to provide particle identification in the difficult intermediate momentum region up to 10 GeV/c. It is also suitable for large-area applications. The detector provides a time-of-flight measurement from the imaging of Cherenkov photons emitted in a 1 cm thick quartz radiator. The photons propagate by total internal reflection to the edge of the quartz plate and are then focused onto an array of photon detectors at the periphery. A time-of-flight resolution of about 10-15 ps per incident charged particle needs to be achieved to allow a three sigma kaon-pion separation up to 10 GeV/c momentum for the TORCH located 9.5 m from the interaction point. Given 30 detected photons per incident charged particle, this requires measuring the time-of-arrival of individual photons to about 70 ps. This paper will describe the design of a TORCH prototype involving a number of ground-breaking and challenging techniques.

  1. TORCH - a Cherenkov-based time-of-flight detector

    CERN Document Server

    van Dijk, M W U; Cowie, E N; Cussans, D; D' Ambrosio, C; Forty, R; Frei, C; Gys, T; Piedigrossi, D; Castillo Garcia, L; Fopma, J; Gao, R; Harnew, N; Keri, T

    2014-01-01

    TORCH is an innovative high-precision time-of-flight system to provide particle identification in the difficult intermediate momentum region up to 10 GeV/c. It is also suitable for large-area applications. The detector provides a time-of-flight measurement from the imaging of Cherenkov photons emitted in a 1 cm thick quartz radiator. The photons propagate by total internal reflection to the edge of the quartz plate, where they are focused onto an array of photon detectors at the periphery. A time-of-flight resolution of about 10–15 ps per incident charged particle needs to be achieved for a three sigma kaon–pion separation up to 10 GeV/c momentum for the TORCH located 9.5 m from the interaction point. Given ∼ 30 detected photons per incident charged particle, this requires measuring the time-of-arrival of individual photons to about 70 ps. This paper will describe the design of a TORCH prototype involving a number of ground-breaking and challenging techniques.

  2. New scintillating media based on liquid crystals for particle detectors

    CERN Document Server

    Barnik, M I; Vasilchenko, V G; Golovkin, S V; Medvedkov, A M; Soloviev, A S

    2000-01-01

    The study results of optical, photoluminiscent and scintillation properties of a liquid crystal 4-pentyl-4'-cyanobiphenyl are presented. The scintillation light output of this liquid crystal is about 35% of crystal anthracene, its main decay time constants are 4 and 14 ns, and the maximum of light emission spectrum is about 400 nm. The light output of a dissolution of green emitting light scintillation dopant R6 in the liquid crystal is about 120% of crystal anthracene. The light output of the frozen dissolution measured at -112 deg. C is about 2.5 times higher as observed at +20 deg. C. In the uniaxially oriented liquid crystal, the predominant intensity direction of emitted light is pointed perpendicular to the liquid crystal director and an appreciable part of the emitted light is elliptically polarized. The possibility to use scintillation properties of liquid crystals is considered both for the improvement of existing particle detector characteristics and for the creation of new gated particle detectors.

  3. Buttock Lifting with Polypropylene Strips.

    Science.gov (United States)

    Ballivian Rico, José; Esteche, Atilio; Hanke, Carlos José Ramírez; Ribeiro, Ricardo Cavalcanti

    2016-04-01

    The purpose of this study was to evaluate the results of gluteal suspension with polypropylene strips. Ninety healthy female patients between the ages of 20 and 50 years (mean, 26 years), who wished to remodel their buttocks from December 2004 to February 2013 were studied retrospectively. All 90 patients were treated with 2 strips of polypropylene on each buttock using the following procedures: 27 (30 %) patients were suspended with polypropylene strips; 63 (70 %) patients were treated with tumescent liposuction in the sacral "V", lower back, supragluteal regions, and flanks to improve buttocks contour (aspirated volume of fat from 350 to 800 cc); 16 (18 %) patients underwent fat grafting in the subcutaneous and intramuscular layers (up to 300 cc in each buttock to increase volume); 5 (6 %) patients received implants to increase volume; and 4 (4.4 %) patients underwent removal and relocation of intramuscular gluteal implants to improve esthetics. Over an 8-year period, 90 female patients underwent gluteal suspension surgeries. Good esthetic results without complications were obtained in 75 of 90 (84 %) cases. Complications occurred in 15 of 90 (16.6 %) patients, including strip removal due to postoperative pain in 1 (1.1 %) patient, and seroma in both subgluteal sulci in 3 (3.3 %) patients. The results of this study performed in 90 patients over 8 years showed that the suspension with polypropylene strips performed as a single procedure or in combination with other cosmetic methods helps to enhance and lift ptosed gluteal and paragluteal areas. This journal requires that the authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

  4. The CMS Silicon Strip Tracker: Design and Production Status

    CERN Document Server

    Affolder, A A

    2004-01-01

    The CMS Silicon Strip Tracker (SST) will be equipped with 15000 silicon micro-strip detector modules covering a surface of 200 m^2. This paper details the SST layout and updates the status of construction. Progress in the fabrication of module components is detailed, with focus on the front-end hybrid and silicon sensor production. The assembly of over 2200 modules using industrial methods is described; the quality assurance protocols have resulted in modules of extremely high mechanical and electrical quality.

  5. Testbeam evaluation of silicon strip modules for ATLAS Phase - II Strip Tracker Upgrade

    CERN Document Server

    Blue, Andrew; The ATLAS collaboration; Ai, Xiaocong; Allport, Phillip; Arling, Jan-Hendrik; Atkin, Ryan Justin; Bruni, Lucrezia Stella; Carli, Ina; Casse, Gianluigi; Chen, Liejian; Chisholm, Andrew; Cormier, Kyle James Read; Cunningham, William Reilly; Dervan, Paul; Diez Cornell, Sergio; Dolezal, Zdenek; Dopke, Jens; Dreyer, Etienne; Dreyling-Eschweiler, Jan Linus Roderik; Escobar, Carlos; Fabiani, Veronica; Fadeyev, Vitaliy; Fernandez Tejero, Javier; Fleta Corral, Maria Celeste; Gallop, Bruce; Garcia-Argos, Carlos; Greenall, Ashley; Gregor, Ingrid-Maria; Greig, Graham George; Guescini, Francesco; Hara, Kazuhiko; Hauser, Marc Manuel; Huang, Yanping; Hunter, Robert Francis Holub; Keller, John; Klein, Christoph; Kodys, Peter; Koffas, Thomas; Kotek, Zdenek; Kroll, Jiri; Kuehn, Susanne; Lee, Steven Juhyung; Liu, Yi; Lohwasser, Kristin; Meszarosova, Lucia; Mikestikova, Marcela; Mi\\~nano Moya, Mercedes; Mori, Riccardo; Moser, Brian; Nikolopoulos, Konstantinos; Peschke, Richard; Pezzullo, Giuseppe; Phillips, Peter William; Poley, Anne-luise; Queitsch-Maitland, Michaela; Ravotti, Federico; Rodriguez Rodriguez, Daniel

    2018-01-01

    The planned HL-LHC (High Luminosity LHC) is being designed to maximise the physics potential of the LHC with 10 years of operation at instantaneous luminosities of \\mbox{$7.5\\times10^{34}\\;\\mathrm{cm}^{-2}\\mathrm{s}^{-1}$}. A consequence of this increased luminosity is the expected radiation damage requiring the tracking detectors to withstand hadron equivalences to over $1x10^{15}$ 1 MeV neutron equivalent per $cm^{2}$ in the ATLAS Strips system. The silicon strip tracker exploits the concept of modularity. Fast readout electronics, deploying 130nm CMOS front-end electronics are glued on top of a silicon sensor to make a module. The radiation hard n-in-p micro-strip sensors used have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics. A series of tests were performed at the DESY-II test beam facility to investigate the detailed performance of a strip module with both 2.5cm and 5cm length strips before irradiation. The DURANTA telescope was used to obtain a pointing...

  6. Determination of trace mercury in water based on N-octylpyridinium ionic liquids preconcentration and stripping voltammetry.

    Science.gov (United States)

    Li, Zhenhan; Xia, Shanhong; Wang, Jinfen; Bian, Chao; Tong, Jianhua

    2016-01-15

    A novel method for determination of trace mercury in water is developed. The method is performed by extracting mercury firstly with ionic liquids (ILs) and then detecting the concentration of mercury in organic media with anodic stripping voltammetry. Liquid-liquid extraction of mercury(II) ions by four ionic liquids with N-octylpyridinium cations ([OPy](+)) was studied. N-octylpyridinium tetrafluoroborate and N-octylpyridinium trifluoromethylsulfonate were found to be efficient and selective extractant for mercury. Temperature controlled dispersive liquid phase microextraction (TC-DLPME) technique was utilized to improve the performance of preconcentration. After extraction, precipitated IL was diluted by acetonitrile buffer and mercury was detected by differential pulse stripping voltammetry (DPSV) with gold disc electrode. Mercury was enriched by 17 times while interfering ions were reduced by two orders of magnitude in the organic media under optimum condition. Sensitivity and selectivity for electrochemical determination of mercury were improved by using the proposed method. Tap, pond and waste water samples were analyzed with recoveries ranging from 81% to 107% and detection limit of 0.05 μg/L. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics.

    Science.gov (United States)

    Park, Byung Hyun; Oh, Seung Jun; Jung, Jae Hwan; Choi, Goro; Seo, Ji Hyun; Kim, Do Hyun; Lee, Eun Yeol; Seo, Tae Seok

    2017-05-15

    Point-of-care (POC) molecular diagnostics plays a pivotal role for the prevention and treatment of infectious diseases. In spite of recent advancement in microfluidic based POC devices, there are still rooms for development to realize rapid, automatic and cost-effective sample-to-result genetic analysis. In this study, we propose an integrated rotary microfluidic system that is capable of performing glass microbead based DNA extraction, loop mediated isothermal amplification (LAMP), and colorimetric lateral flow strip based detection in a sequential manner with an optimized microfluidic design and a rotational speed control. Rotation direction-dependent coriolis force and siphon valving structures enable us to perform the fluidic control and metering, and the use of the lateral flow strip as a detection method renders all the analytical processes for nucleic acid test simplified and integrated without the need of expensive instruments or human intervention. As a proof of concept for point-of-care DNA diagnostics, we identified the food-borne bacterial pathogen which was contaminated in water or milk. Not only monoplex Salmonella Typhimurium but also multiplex Salmonella Typhimurium and Vibrio parahaemolyticus were analysed on the integrated rotary genetic analysis microsystem with a limit of detection of 50 CFU in 80min. In addition, three multiple samples were simultaneously analysed on a single device. The sample-to-result capability of the proposed microdevice provides great usefulness in the fields of clinical diagnostics, food safety and environment monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Gamma-Free Neutron Detector Based upon Lithium Phosphate Nanoparticles

    International Nuclear Information System (INIS)

    Steven Wallace

    2007-01-01

    A gamma-free neutron-sensitive scintillator is needed to enhance radiation sensing and detection for nonproliferation applications. Such a scintillator would allow very large detectors to be placed at the perimeter of spent-fuel storage facilities at commercial nuclear power plants, so that any movement of spontaneously emitted neutrons from spent nuclear fuel or weapons grade plutonium would be noted in real-time. This task is to demonstrate that the technology for manufacturing large panels of fluor-doped plastic containing lithium-6 phosphate nanoparticles can be achieved. In order to detect neutrons, the nanoparticles must be sufficiently small so that the plastic remains transparent. In this way, the triton and alpha particles generated by the capture of the neutron will result in a photon burst that can be coupled to a wavelength shifting fiber (WLS) producing an optical signal of about ten nanoseconds duration signaling the presence of a neutron emitting source

  9. Gamma-Free Neutron Detector Based upon Lithium Phosphate Nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Steven Wallace

    2007-08-28

    A gamma-free neutron-sensitive scintillator is needed to enhance radiaition sensing and detection for nonproliferation applications. Such a scintillator would allow very large detectors to be placed at the perimeter of spent-fuel storage facilities at commercial nuclear power plants, so that any movement of spontaneously emitted neutrons from spent nuclear fuel or weapons grade plutonium would be noted in real-time. This task is to demonstrate that the technology for manufacturing large panels of fluor-doped plastic containing lithium-6 phosphate nanoparticles can be achieved. In order to detect neutrons, the nanoparticles must be sufficiently small so that the plastic remains transparent. In this way, the triton and alpha particles generated by the capture of the neutron will result in a photon burst that can be coupled to a wavelength shifting fiber (WLS) producing an optical signal of about ten nanoseconds duration signaling the presence of a neutron emitting source.

  10. OFDM Signal Detector Based on Cyclic Autocorrelation Function and its Properties

    Directory of Open Access Journals (Sweden)

    Z. Fedra

    2011-12-01

    Full Text Available This paper is devoted to research of the general and particular properties of the OFDM signal detector based on the cyclic autocorrelation function. The cyclic autocorrelation function is estimated using DFT. The parameters of the testing signal have been chosen according to 802.11g WLAN. Some properties are described analytically; all events are examined via computer simulations. It is shown that the detector is able to detect an OFDM signal in the case of multipath propagation, inexact frequency synchronization and without time synchronization. The sensitivity of the detector could be decreased in the above cases. An important condition for proper value of the detector sampling interval was derived. Three types of the channels were studied and compared. Detection threshold SNR=-9 dB was found for the signal under consideration and for two-way propagation.

  11. Photovoltaic X-ray detectors based on epitaxial GaAs structures

    Energy Technology Data Exchange (ETDEWEB)

    Achmadullin, R.A. [Institute of Radio Engineering and Electronics, Russian Academy of Sciences, 1 Ac. Vvedenski square, Fryazino 141190, Moscow region (Russian Federation); Artemov, V.V. [Shubnikov Institute of Crystallography, Russian Academy of Sciences, 59 Leninski pr., Moscow B-333, 117333 (Russian Federation); Dvoryankin, V.F. [Institute of Radio Engineering and Electronics, Russian Academy of Sciences, 1 Ac. Vvedenski square, Fryazino 141190, Moscow region (Russian Federation)]. E-mail: vfd217@ire216.msk.su; Dvoryankina, G.G. [Institute of Radio Engineering and Electronics, Russian Academy of Sciences, 1 Ac. Vvedenski square, Fryazino 141190, Moscow region (Russian Federation); Dikaev, Yu.M. [Institute of Radio Engineering and Electronics, Russian Academy of Sciences, 1 Ac. Vvedenski square, Fryazino 141190, Moscow region (Russian Federation); Ermakov, M.G. [Institute of Radio Engineering and Electronics, Russian Academy of Sciences, 1 Ac. Vvedenski square, Fryazino 141190, Moscow region (Russian Federation); Ermakova, O.N. [Institute of Radio Engineering and Electronics, Russian Academy of Sciences, 1 Ac. Vvedenski square, Fryazino 141190, Moscow region (Russian Federation); Chmil, V.B. [Scientific State Center, High Energy Physics Institute, Protvino, Moscow region (Russian Federation); Holodenko, A.G. [Scientific State Center, High Energy Physics Institute, Protvino, Moscow region (Russian Federation); Kudryashov, A.A.; Krikunov, A.I.; Petrov, A.G.; Telegin, A.A. [Institute of Radio Engineering and Electronics, Russian Academy of Sciences, 1 Ac. Vvedenski square, Fryazino 141190, Moscow region (Russian Federation); Vorobiev, A.P. [Scientific State Center, High Energy Physics Institute, Protvino, Moscow region (Russian Federation)

    2005-12-01

    A new type of the photovoltaic X-ray detector based on epitaxial p{sup +}-n-n'-n{sup +} GaAs structures which provides a high efficiency of charge collection in the non-bias operation mode at room temperature is proposed. The GaAs epitaxial structures were grown by vapor-phase epitaxy on heavily doped n{sup +}-GaAs(1 0 0) substrates. The absorption efficiency of GaAs X-ray detector is discussed. I-V and C-V characteristics of the photovoltaic X-ray detectors are analyzed. The built-in electric field profiles in the depletion region of epitaxial structures are measured by the EBIC method. Charge collection efficiency to {alpha}-particles and {gamma}-radiation are measured. The application of X-ray detectors is discussed.

  12. Numerical Investigation on Electron and Ion Transmission of GEM-based Detectors

    Science.gov (United States)

    Bhattacharya, Purba; Sahoo, Sumanya Sekhar; Biswas, Saikat; Mohanty, Bedangadas; Majumdar, Nayana; Mukhopadhyay, Supratik

    2018-02-01

    ALICE at the LHC is planning a major upgrade of its detector systems, including the TPC, to cope with an increase of the LHC luminosity after 2018. Different R&D activities are currently concentrated on the adoption of the Gas Electron Multiplier (GEM) as the gas amplification stage of the ALICE-TPC upgrade version. The major challenge is to have low ion feedback in the drift volume as well as to ensure a collection of good percentage of primary electrons in the signal generation process. In the present work, Garfield simulation framework has been adopted to numerically estimate the electron transparency and ion backflow fraction of GEM-based detectors. In this process, extensive simulations have been carried out to enrich our understanding of the complex physical processes occurring within single, triple and quadruple GEM detectors. A detailed study has been performed to observe the effect of detector geometry, field configuration and magnetic field on the above mentioned characteristics.

  13. A hybrid multiuser detector based on MMSE and AFSA for TDRS system forward link.

    Science.gov (United States)

    Yin, Zhendong; Jiang, Xu; Wu, Zhilu; Liu, Xiaohui

    2014-01-01

    This study mainly focuses on multiuser detection in tracking and data relay satellite (TDRS) system forward link. Minimum mean square error (MMSE) is a low complexity multiuser detection method, but MMSE detector cannot achieve satisfactory bit error ratio and near-far resistance, whereas artificial fish swarm algorithm (AFSA) is expert in optimization and it can realize the global convergence efficiently. Therefore, a hybrid multiuser detector based on MMSE and AFSA (MMSE-AFSA) is proposed in this paper. The result of MMSE and its modified formations are used as the initial values of artificial fishes to accelerate the speed of global convergence and reduce the iteration times for AFSA. The simulation results show that the bit error ratio and near-far resistance performances of the proposed detector are much better, compared with MF, DEC, and MMSE, and are quite close to OMD. Furthermore, the proposed MMSE-AFSA detector also has a large system capacity.

  14. The Algorithm for Blind Multi-user Detector Based on Subspace Tracking

    Directory of Open Access Journals (Sweden)

    Meng JIA

    2014-04-01

    Full Text Available Multi-user detection (MUD is an efficient technique for interference suppression that reduces the Multiple access interference (MAI and improves the performance and increases the capacity of the system. Nowadays most of the research to MUD focuses on the blind multi-user detector because it does not require training sequences and can save the spectrum resource. By applying an improved subspace tracking algorithm to a modified subspace-based linear MMSE multi-user detector, a blind multi-user detector is presented. For the improved subspace tracking algorithm can reduce considerably computational complexity while keeping satisfactory convergence speed and stability and the modified MMSE multi-user detector doesn’t require the estimation of eigenvalue matrix, there can be significant elevation in the detection performance. Simulation results demonstrate preliminarily the conclusions above.

  15. A Time-Walk Correction Method for PET Detectors Based on Leading Edge Discriminators.

    Science.gov (United States)

    Du, Junwei; Schmall, Jeffrey P; Judenhofer, Martin S; Di, Kun; Yang, Yongfeng; Cherry, Simon R

    2017-09-01

    The leading edge timing pick-off technique is the simplest timing extraction method for PET detectors. Due to the inherent time-walk of the leading edge technique, corrections should be made to improve timing resolution, especially for time-of-flight PET. Time-walk correction can be done by utilizing the relationship between the threshold crossing time and the event energy on an event by event basis. In this paper, a time-walk correction method is proposed and evaluated using timing information from two identical detectors both using leading edge discriminators. This differs from other techniques that use an external dedicated reference detector, such as a fast PMT-based detector using constant fraction techniques to pick-off timing information. In our proposed method, one detector was used as reference detector to correct the time-walk of the other detector. Time-walk in the reference detector was minimized by using events within a small energy window (508.5 - 513.5 keV). To validate this method, a coincidence detector pair was assembled using two SensL MicroFB SiPMs and two 2.5 mm × 2.5 mm × 20 mm polished LYSO crystals. Coincidence timing resolutions using different time pick-off techniques were obtained at a bias voltage of 27.5 V and a fixed temperature of 20 °C. The coincidence timing resolution without time-walk correction were 389.0 ± 12.0 ps (425 -650 keV energy window) and 670.2 ± 16.2 ps (250-750 keV energy window). The timing resolution with time-walk correction improved to 367.3 ± 0.5 ps (425 - 650 keV) and 413.7 ± 0.9 ps (250 - 750 keV). For comparison, timing resolutions were 442.8 ± 12.8 ps (425 - 650 keV) and 476.0 ± 13.0 ps (250 - 750 keV) using constant fraction techniques, and 367.3 ± 0.4 ps (425 - 650 keV) and 413.4 ± 0.9 ps (250 - 750 keV) using a reference detector based on the constant fraction technique. These results show that the proposed leading edge based time-walk correction method works well. Timing resolution obtained

  16. A Correlation-Based Joint CFAR Detector Using Adaptively-Truncated Statistics in SAR Imagery.

    Science.gov (United States)

    Ai, Jiaqiu; Yang, Xuezhi; Zhou, Fang; Dong, Zhangyu; Jia, Lu; Yan, He

    2017-03-27

    Traditional constant false alarm rate (CFAR) detectors only use the contrast information between ship targets and clutter, and they suffer probability of detection (PD) degradation in multiple target situations. This paper proposes a correlation-based joint CFAR detector using adaptively-truncated statistics (hereafter called TS-2DLNCFAR) in SAR images. The proposed joint CFAR detector exploits the gray intensity correlation characteristics by building a two-dimensional (2D) joint log-normal model as the joint distribution (JPDF) of the clutter, so joint CFAR detection is realized. Inspired by the CFAR detection methodology, we design an adaptive threshold-based clutter truncation method to eliminate the high-intensity outliers, such as interfering ship targets, side-lobes, and ghosts in the background window, whereas the real clutter samples are preserved to the largest degree. A 2D joint log-normal model is accurately built using the adaptively-truncated clutter through simple parameter estimation, so the joint CFAR detection performance is greatly improved. Compared with traditional CFAR detectors, the proposed TS-2DLNCFAR detector achieves a high PD and a low false alarm rate (FAR) in multiple target situations. The superiority of the proposed TS-2DLNCFAR detector is validated on the multi-look Envisat-ASAR and TerraSAR-X data.

  17. Flexible X-ray detector based on sliced lead iodide crystal

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Hui; Gao, Xiuying [College of Optoelectronic Technology, Chengdu University of Information Technology, Chengdu (China); Department of Materials Science, Sichuan University, Chengdu (China); Zhao, Beijun [Department of Materials Science, Sichuan University, Chengdu (China); Yang, Dingyu; Wangyang, Peihua; Zhu, Xinghua [College of Optoelectronic Technology, Chengdu University of Information Technology, Chengdu (China)

    2017-02-15

    A promising flexible X-ray detector based on inorganic semiconductor PbI{sub 2} crystal is reported. The sliced crystals mechanically cleaved from an as-grown PbI{sub 2} crystal act as the absorber directly converting the impinging X-ray photons to electron hole pairs. Due to the ductile feature of the PbI{sub 2} crystal, the detector can be operated under a highly curved state with the strain on the top surface up to 1.03% and still maintaining effective detection performance. The stable photocurrent and fast response were obtained with the detector repeated bending to a strain of 1.03% for 100 cycles. This work presents an approach for developing efficient and cost-effective PbI{sub 2}-based flexible X-ray detector. Photocurrent responses of the flexible PbI{sub 2} X-ray detector with the strain on the top surface up to 1.03% proposed in this work with the cross sectional structure and curved detector photograph as insets. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Multi-class geospatial object detection and geographic image classification based on collection of part detectors

    Science.gov (United States)

    Cheng, Gong; Han, Junwei; Zhou, Peicheng; Guo, Lei

    2014-12-01

    The rapid development of remote sensing technology has facilitated us the acquisition of remote sensing images with higher and higher spatial resolution, but how to automatically understand the image contents is still a big challenge. In this paper, we develop a practical and rotation-invariant framework for multi-class geospatial object detection and geographic image classification based on collection of part detectors (COPD). The COPD is composed of a set of representative and discriminative part detectors, where each part detector is a linear support vector machine (SVM) classifier used for the detection of objects or recurring spatial patterns within a certain range of orientation. Specifically, when performing multi-class geospatial object detection, we learn a set of seed-based part detectors where each part detector corresponds to a particular viewpoint of an object class, so the collection of them provides a solution for rotation-invariant detection of multi-class objects. When performing geographic image classification, we utilize a large number of pre-trained part detectors to discovery distinctive visual parts from images and use them as attributes to represent the images. Comprehensive evaluations on two remote sensing image databases and comparisons with some state-of-the-art approaches demonstrate the effectiveness and superiority of the developed framework.

  19. Hydrologic Response Unit Routing in SWAT to Simulate Effects of Vegetated Filter Strip for South-Korean Conditions Based on VFSMOD

    Directory of Open Access Journals (Sweden)

    Kyoung Jae Lim

    2011-08-01

    Full Text Available The Soil and Water Assessment Tool (SWAT model has been used worldwide for many hydrologic and Non-Point Source (NPS Pollution analyses on a watershed scale. However, it has many limitations in simulating the Vegetative Filter Strip (VFS because it considers only ‘filter strip width’ when the model estimates sediment trapping efficiency and does not consider the routing of sediment with overland flow which is expected to maximize the sediment trapping efficiency from upper agricultural subwatersheds to lower spatially-explicit filter strips. Therefore, the SWAT overland flow option between landuse-subwatersheds with sediment routing capability was enhanced by modifying the SWAT watershed configuration and SWAT engine based on the numerical model VFSMOD applied to South-Korean conditions. The enhanced SWAT can simulate the VFS sediment trapping efficiency for South-Korean conditions in a manner similar to the desktop VFSMOD-w system. Due to this enhancement, SWAT is applicable to simulate the effects of overland flow from upper subwatersheds to reflect increased runoff volume at the lower subwatershed, which occurs in the field if no diversion channel is installed. In this study, the enhanced SWAT model was applied to small watersheds located at Jaun-ri in South-Korea to simulate a diversion channel and spatially-explicit VFS. Sediment can be reduced by 31%, 65%, and 68%, with a diversion channel, the VFS, and the VFS with diversion channel, respectively. The enhanced SWAT should be used in estimating site-specific effects on sediment reduction with diversion channels and VFS, instead of the currently available SWAT, which does not simulate sediment routing in overland flow and does not consider other sensitive factors affecting sediment reduction with VFS.

  20. An Analysis of Delay-based and Integrator-based Sequence Detectors for Grid-Connected Converters

    DEFF Research Database (Denmark)

    Khazraj, Hesam; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    Detecting and separating positive and negative sequence components of the grid voltage or current is of vital importance in the control of grid-connected power converters, HVDC systems, etc. To this end, several techniques have been proposed in recent years. These techniques can be broadly...... classified into two main classes: The integrator-based techniques and Delay-based techniques. The complex-coefficient filter-based technique, dual second-order generalized integrator-based method, multiple reference frame approach are the main members of the integrator-based sequence detector and the delay......-signal cancellation operators are the main members of the delay-based sequence detectors. The aim of this paper is to provide a theoretical and experimental comparative study between integrator and delay based sequence detectors. The theoretical analysis is conducted based on the small-signal modelling...