WorldWideScience

Sample records for strip chart recorder

  1. Automatic Extraction of High-Resolution Rainfall Series from Rainfall Strip Charts

    Science.gov (United States)

    Saa-Requejo, Antonio; Valencia, Jose Luis; Garrido, Alberto; Tarquis, Ana M.

    2015-04-01

    Soil erosion is a complex phenomenon involving the detachment and transport of soil particles, storage and runoff of rainwater, and infiltration. The relative magnitude and importance of these processes depends on a host of factors, including climate, soil, topography, cropping and land management practices among others. Most models for soil erosion or hydrological processes need an accurate storm characterization. However, this data are not always available and in some cases indirect models are generated to fill this gap. In Spain, the rain intensity data known for time periods less than 24 hours back to 1924 and many studies are limited by it. In many cases this data is stored in rainfall strip charts in the meteorological stations but haven't been transfer in a numerical form. To overcome this deficiency in the raw data a process of information extraction from large amounts of rainfall strip charts is implemented by means of computer software. The method has been developed that largely automates the intensive-labour extraction work based on van Piggelen et al. (2011). The method consists of the following five basic steps: 1) scanning the charts to high-resolution digital images, 2) manually and visually registering relevant meta information from charts and pre-processing, 3) applying automatic curve extraction software in a batch process to determine the coordinates of cumulative rainfall lines on the images (main step), 4) post processing the curves that were not correctly determined in step 3, and 5) aggregating the cumulative rainfall in pixel coordinates to the desired time resolution. A colour detection procedure is introduced that automatically separates the background of the charts and rolls from the grid and subsequently the rainfall curve. The rainfall curve is detected by minimization of a cost function. Some utilities have been added to improve the previous work and automates some auxiliary processes: readjust the bands properly, merge bands when

  2. Weighing Rain Gauge Recording Charts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Weighing rain gauge charts record the amount of precipitation that falls at a given location. The vast majority of the Weighing Rain Gauge Recording Charts...

  3. Development of Markup Language for Medical Record Charting: A Charting Language.

    Science.gov (United States)

    Jung, Won-Mo; Chae, Younbyoung; Jang, Bo-Hyoung

    2015-01-01

    Nowadays a lot of trials for collecting electronic medical records (EMRs) exist. However, structuring data format for EMR is an especially labour-intensive task for practitioners. Here we propose a new mark-up language for medical record charting (called Charting Language), which borrows useful properties from programming languages. Thus, with Charting Language, the text data described in dynamic situation can be easily used to extract information.

  4. Qualities of dental chart recording and coding.

    Science.gov (United States)

    Chantravekin, Yosananda; Tasananutree, Munchulika; Santaphongse, Supitcha; Aittiwarapoj, Anchisa

    2013-01-01

    Chart recording and coding are the important processes in the healthcare informatics system, but there were only a few reports in the dentistry field. The objectives of this study are to study the qualities of dental chart recording and coding, as well as the achievement of lecture/workshop on this topic. The study was performed by auditing the patient's charts at the TU Dental Student Clinic from July 2011-August 2012. The chart recording mean scores ranged from 51.0-55.7%, whereas the errors in the coding process were presented in the coder part more than the doctor part. The lecture/workshop could improve the scores only in some topics.

  5. Inaccurate Dental Charting in an Audit of 1128 General Dental Practice Records.

    Science.gov (United States)

    Brown, Nathan L; Jephcote, Victoria E L

    2017-03-01

    Fourteen dentists at different practices in the UK assessed the dental charts of 1128 patients who were new to the dentist but not new to the practice; 44% of the dental charts were found to be inaccurate. Inaccuracy of the individual practice-based charts ranged between 16% for the best performing practices to 83% for the worst: 5% of dental charts had too many teeth charted and 5% had too few teeth charted; 13% of charts had missed amalgam restorations and 18% had missed tooth-coloured restorations; 5% of charts had amalgam restorations recorded but with the surfaces incorrect (eg an MO restoration charted but a DO restoration actually present); 9% of charts had tooth-coloured restoration surfaces incorrectly recorded. For 7.5% of charts, amalgams were charted but not actually present. Other inaccuracies were also noted. The authors reinforce the requirements of the GDC, the advice of defence organizations, and the forensic importance of accurate dental charts. Clinical relevance: Dental charting forms part of the patient’s dental records, and the GDC requires dentists to maintain complete and accurate dental records.

  6. Paperless chart recording helps cut costs

    International Nuclear Information System (INIS)

    Collier, K.; Sullivan, M.E.

    1997-01-01

    Turbine generator data acquisition systems using personal computers have been installed at the Limerick BWR power plant to replace paper-based chart recorders. This plant is already one of the lowest cost nuclear power plants in the US and this innovation will boost operating efficiency still further. The Limerick control room now has wall-mounted touch screen video displays which provide operators with real-time, electronically achieved information and improving information flow, with a consolidated, consistent user interface. (UK)

  7. Development of electronic medical record charting for hospital-based transfusion and apheresis medicine services: Early adoption perspectives

    Directory of Open Access Journals (Sweden)

    Rebecca Levy

    2010-01-01

    Full Text Available Background: Electronic medical records (EMRs provide universal access to health care information across multidisciplinary lines. In pathology departments, transfusion and apheresis medicine services (TAMS involved in direct patient care activities produce data and documentation that typically do not enter the EMR. Taking advantage of our institution′s initiative for implementation of a paperless medical record, our TAMS division set out to develop an electronic charting (e-charting strategy within the EMR. Methods: A focus group of our hospital′s transfusion committee consisting of transfusion medicine specialists, pathologists, residents, nurses, hemapheresis specialists, and information technologists was constituted and charged with the project. The group met periodically to implement e-charting TAMS workflow and produced electronic documents within the EMR (Cerner Millenium for various service line functions. Results: The interdisciplinary working group developed and implemented electronic versions of various paper-based clinical documentation used by these services. All electronic notes collectively gather and reside within a unique Transfusion Medicine Folder tab in the EMR, available to staff with access to patient charts. E-charting eliminated illegible handwritten notes, resulted in more consistent clinical documentation among staff, and provided greater real-time review/access of hemotherapy practices. No major impediments to workflow or inefficiencies have been encountered. However, minor updates and corrections to documents as well as select work re-designs were required for optimal use of e-charting by these services. Conclusion: Documentation of pathology subspecialty activities such as TAMS can be successfully incorporated into the EMR. E-charting by staff enhances communication and helps promote standardized documentation of patient care within and across service lines. Well-constructed electronic documents in the EMR may also

  8. Chart Audit and Chart Stimulated Recall as Methods of Needs Assessment in Continuing Professional Health Education.

    Science.gov (United States)

    Affleck, Louise; Jennett, Penny

    1998-01-01

    Chart audit (assessment of patient medical records) is a cost-effective continuing-education needs-assessment method. Chart stimulated recall, in which physicians' memory of particular cases is stimulated by records, potentially increases content validity and exploration of clinical reasoning as well as the context of clinical decisions. (SK)

  9. Angular dependence on the records of dose in radiochromic films strips

    Energy Technology Data Exchange (ETDEWEB)

    Costa, K. C.; Prata M, A. [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil); Alonso, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear - CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Campo de O, P. M., E-mail: kamilacosta1995@gmail.com [Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagen, Av. Prof. Alfredo Balena 190, 30130-100 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Radiological images have relevant information both the diagnostic results as to treatment decisions. Then, the diagnostic quality of image that allows a proper analysis should be achieved with the lowest possible deposition of dose in a patient. CT scans produce sectional images that allow the observation of internal structures of the human body without overlap. As in conventional radiology, the contrast which allows obtaining CT images results from the difference in X-ray beam absorption, according to the characteristics of each tissue. The increased of the beam absorption by a tissue means that it appears brighter in the image. In CT scanners, X-ray tube rotates around the patient, and this rotation results in a cross-sectional image of the body. From a sectional image series is possible to obtain a 3-dimensional image that can be viewed from different angles. Among the methods of dose measurement is the use of radiochromic films, which record the energy deposition by darkening its emulsion. The radiochromic films show little sensitivity to visible light and respond better to exposure to ionizing radiation. In this work, strips of the radiochromic film GAFCHROMIC XR-QA2 were irradiated at different angular positions for radiation quality RQT8, defining a beam of X-rays generated from a voltage of 100 kV. The response of radiochromic films depending on the doses was assessed through digital images obtained by H P Scan jet G-4050 scanner. Digital images were analyzed using Image-J software, which allowed obtaining numerical values corresponding to the intensity of darkening for each film. The aim of this study is to evaluate the dose deposition in radiochromic film according to the angular variation in order how is affected the record. So, to examine the use of film strips to record doses in Computed Tomography tests. (Author)

  10. SinaPlot: an enhanced chart for simple and truthful representation of single observations over multiple classes

    DEFF Research Database (Denmark)

    Sidiropoulos, Nikos; Sohi, Sina Hadi; Pedersen, Thomas Lin

    2017-01-01

    the representation of data sets with differing sample size we have developed a new type of plot overcoming limitations of current standard visualization charts. SinaPlot is inspired by the strip chart and the violin plot and operates by letting the normalized density of points restrict the jitter along the x...

  11. The study of insect blood-feeding behaviour: 2. Recording techniques and the use of flow charts

    Directory of Open Access Journals (Sweden)

    J. J. B. Smith

    1987-01-01

    Full Text Available This paper continues a discussion of approaches and methodologies we have used in our studies of feeding in haematophagous insects. Described are techniques for directly monitoring behaviour: electrical recording of feeding behaviour via resistance changes in the food canal, optical methods for monitoring mouthpart activity, and a computer technique for behavioural event recording. Also described is the use of "flow charts" or "decision diagrams" to model interrelated sequences of behaviours.

  12. Barograms / Barograph Charts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Barograms are weekly rectangular charts recording barometric pressure at a given station. The barograph is an instrument that makes a continuous pen and ink trace of...

  13. Dual Approach to Amplify Anodic Stripping Voltammetric Signals Recorded Using Screen Printed Electrodes

    Directory of Open Access Journals (Sweden)

    Agnieszka KRÓLICKA

    2016-12-01

    Full Text Available Screen printed electrodes plated with bismuth were used to record anodic stripping voltammograms of Pb(II, In(III and Cd(II. Using two bismuth precursors: Bi2O3 dispersed in the electrode body and Bi(III ions spiked into the tested solution it was possible to deposit bismuth layers, demonstrating exceptional ability to accumulate metals forming alloys with bismuth. The voltammetric signals were amplified by adjusting the electrode location with respect to rotating magnetic field. The electrode response was influenced by vertical and horizontal distance between the magnet center and the sensing area of screen printed electrode as well as the angle between the magnet surface and the electrode. When the electrode was moved away from the magnet center the recorded peaks were increasingly smaller and almost not affected by the presence of bismuth ions. It was shown that to obtain well-shaped signals a favourable morphology of bismuth deposits is of key importance. Hypotheses explaining processes responsible for the amplification of voltammetric signals were proposed.

  14. Strip interpolation in silicon and germanium strip detectors

    International Nuclear Information System (INIS)

    Wulf, E. A.; Phlips, B. F.; Johnson, W. N.; Kurfess, J. D.; Lister, C. J.; Kondev, F.; Physics; Naval Research Lab.

    2004-01-01

    The position resolution of double-sided strip detectors is limited by the strip pitch and a reduction in strip pitch necessitates more electronics. Improved position resolution would improve the imaging capabilities of Compton telescopes and PET detectors. Digitizing the preamplifier waveform yields more information than can be extracted with regular shaping electronics. In addition to the energy, depth of interaction, and which strip was hit, the digitized preamplifier signals can locate the interaction position to less than the strip pitch of the detector by looking at induced signals in neighboring strips. This allows the position of the interaction to be interpolated in three dimensions and improve the imaging capabilities of the system. In a 2 mm thick silicon strip detector with a strip pitch of 0.891 mm, strip interpolation located the interaction of 356 keV gamma rays to 0.3 mm FWHM. In a 2 cm thick germanium detector with a strip pitch of 5 mm, strip interpolation of 356 keV gamma rays yielded a position resolution of 1.5 mm FWHM

  15. Area specific stripping factors for AGS. A method for extracting stripping factors from survey data

    Energy Technology Data Exchange (ETDEWEB)

    Aage, H.K.; Korsbech, U. [Technical Univ. of Denmark (Denmark)

    2006-04-15

    In order to use Airborne Gamma-ray Spectrometry (AGS) for contamination mapping, for source search etc. one must to be able to eliminate the contribution to the spectra from natural radioactivity. This in general is done by a stripping technique. The parameters for performing a stripping have until recently been measured by recording gamma spectra at special calibration sites (pads). This may be cumbersome and the parameters may not be correct when used at low gamma energies for environmental spectra. During 2000-2001 DTU tested with success a new technique for Carborne Gamma-ray Spectrometry (CGS) where the spectra from the surveyed area (or from a similar area) were used for calculating the stripping parameters. It was possible to calculate usable stripping ratios for a number of low energy windows - and weak source signals not detectable by other means were discovered with the ASS technique. In this report it is shown that the ASS technique also works for AGS data, and it has been used for recent Danish AGS tests with point sources. (Check of calibration of AGS parameters.) By using the ASS technique with the Boden data (Barents Rescue) an exercise source was detected that has not been detected by any of the teams during the exercise. The ASS technique therefore seems to be better for search for radiation anomalies than any other method known presently. The experiences also tell that although the stripping can be performed correctly at any altitude there is a variation of the stripping parameters with altitude that has not yet been quite understood. However, even with the oddly variations the stripping worked as expected. It was also observed that one might calculate a single common set of usable stripping factors for all altitudes from the entire data set i.e. some average a, b and c values. When those stripping factors were used the stripping technique still worked well. (au)

  16. Electronic growth charts: watching our patients grow.

    Science.gov (United States)

    Murphy, Cynthia A; Carstens, Kimberly; Villamayor, Precy

    2005-01-01

    Pediatric Growth Charts have been used in the pediatric community since 1977. The first growth charts were developed by the National Center for Health Statistics as a clinical tool for health care professionals. The growth charts, revised in 2000, by the Center for Disease Control consists of a series of percentile curves for selected body measurements in children [1]. Capitalizing on the benefits of our Electronic Medical Record (EMR), and as a byproduct of nursing electronic documentation of routine heights, weights, and frontal occipital circumferences, our system plots the routine measurements without additional intervention by the staff. Clinicians can view the graphs online or generate printed reports as needed during routine examination for outpatient or hospitalized care. This abstract outlines the background, design process, programming rules utilized to plot growth curves, and the evaluation of the electronic CDC growth charts in our organization.

  17. Comparative characteristics of polystyrene scintillation strips

    International Nuclear Information System (INIS)

    Gapienko, V.A.; Denisov, A.G.; Mel'nikov, E.A.

    1992-01-01

    Results are provided for a study of the main characteristics of polystyrene scintillation strips with a cross-section of 200 x 10 mm with two different scintillation-additive compositions: 1.5% p-terphenyl + 0.01% POPOP and 1.5% p-terphenyl + 0.01% DBP. The mean light-attenuation lengths are 180 cm and 260 cm, respectively, for strips with POPOP and DBP. The emittances of the polystyrene scintillators with DBP and POPOP additives have a ratio of 0.8:1.0 as recorded by an FEU-110 photomultiplier. 2 refs., 1 fig., 2 tabs

  18. An Application of Geospatial Information Systems (GIS) Technology to Anatomic Dental Charting

    OpenAIRE

    Bartling, William C.; Schleyer, Titus K.L.

    2003-01-01

    Historically, an anatomic dental chart is a compilation of color-coded symbols and numbers used within a template, either paper or computerized, to create a graphic record of a patient’s oral health status. This poster depicts how Geospatial Information System (GIS) technology can be used to create an accurate, current anatomic dental chart that contains detailed information not present in current charting systems.

  19. Comparison of accuracy of physical examination findings in initial progress notes between paper charts and a newly implemented electronic health record.

    Science.gov (United States)

    Yadav, Siddhartha; Kazanji, Noora; K C, Narayan; Paudel, Sudarshan; Falatko, John; Shoichet, Sandor; Maddens, Michael; Barnes, Michael A

    2017-01-01

    There have been several concerns about the quality of documentation in electronic health records (EHRs) when compared to paper charts. This study compares the accuracy of physical examination findings documentation between the two in initial progress notes. Initial progress notes from patients with 5 specific diagnoses with invariable physical findings admitted to Beaumont Hospital, Royal Oak, between August 2011 and July 2013 were randomly selected for this study. A total of 500 progress notes were retrospectively reviewed. The paper chart arm consisted of progress notes completed prior to the transition to an EHR on July 1, 2012. The remaining charts were placed in the EHR arm. The primary endpoints were accuracy, inaccuracy, and omission of information. Secondary endpoints were time of initiation of progress note, word count, number of systems documented, and accuracy based on level of training. The rate of inaccurate documentation was significantly higher in the EHRs compared to the paper charts (24.4% vs 4.4%). However, expected physical examination findings were more likely to be omitted in the paper notes compared to EHRs (41.2% vs 17.6%). Resident physicians had a smaller number of inaccuracies (5.3% vs 17.3%) and omissions (16.8% vs 33.9%) compared to attending physicians. During the initial phase of implementation of an EHR, inaccuracies were more common in progress notes in the EHR compared to the paper charts. Residents had a lower rate of inaccuracies and omissions compared to attending physicians. Further research is needed to identify training methods and incentives that can reduce inaccuracies in EHRs during initial implementation. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Comparison of reading speed with 3 different log-scaled reading charts.

    Science.gov (United States)

    Buari, Noor Halilah; Chen, Ai-Hong; Musa, Nuraini

    2014-01-01

    A reading chart that resembles real reading conditions is important to evaluate the quality of life in terms of reading performance. The purpose of this study was to compare the reading speed of UiTM Malay related words (UiTM-Mrw) reading chart with MNread Acuity Chart and Colenbrander Reading Chart. Fifty subjects with normal sight were randomly recruited through randomized sampling in this study (mean age=22.98±1.65 years). Subjects were asked to read three different near charts aloud and as quickly as possible at random sequence. The charts were the UiTM-Mrw Reading Chart, MNread Acuity Chart and Colenbrander Reading Chart, respectively. The time taken to read each chart was recorded and any errors while reading were noted. Reading performance was quantified in terms of reading speed as words per minute (wpm). The mean reading speed for UiTM-Mrw Reading Chart, MNread Acuity Chart and Colenbrander Reading Chart was 200±30wpm, 196±28wpm and 194±31wpm, respectively. Comparison of reading speed between UiTM-Mrw Reading Chart and MNread Acuity Chart showed no significant difference (t=-0.73, p=0.72). The same happened with the reading speed between UiTM-Mrw Reading Chart and Colenbrander Reading Chart (t=-0.97, p=0.55). Bland and Altman plot showed good agreement between reading speed of UiTM-Mrw Reading Chart with MNread Acuity Chart with the Colenbrander Reading Chart. UiTM-Mrw Reading Chart in Malay language is highly comparable with standardized charts and can be used for evaluating reading speed. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  1. Development and clinical application of a color pediatric visual acuity chart

    Directory of Open Access Journals (Sweden)

    Shu-Guo Yin

    2014-12-01

    Full Text Available AIM: To introduce a new color pediatric visual acuity chart and its clinical application.METHODS:The color pediatric visual acuity chart was designed based on principle of visual angle. The optotype on the color chart had graphics. The progression rate of optotype size between 2 lines was 10(101/2 and 1.2589. A regular geometric progression of optotype sizes and distribution was employed to arrange 8 lines with 11 optotype on the color chart. The testing distance was 3m. The visual acuity score could be recorded as logarithm of the minimum angle of resolution notation or decimal notation. The reliability of naked distant measurements with this new chart was tested in one eye of 100 children(4 ~6 years oldtaking the Chinese national standard logarithm visual acuity chart standard. RESULTS: The color pediatric visual acuity chart and logarithmic chart controls, visual acuity test results that in the two groups had no significant difference(t=1.2671, P>0.05. Two sets of vision data existed positive correlation(r=0.924, PCONCLUSION:Children are easier to accept used new color pediatric visual acuity chart to inspect vision. New chart is reliability and apply to children's vision screening.

  2. Body Mass Index (BMI) Charts (For Parents)

    Science.gov (United States)

    ... Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for ... charts for boys and girls to account for differences in growth rates and amounts of body fat as the two genders mature. That information is recorded in your child's ...

  3. Concordance of chart and billing data with direct observation in dental practice.

    Science.gov (United States)

    Demko, Catherine A; Victoroff, Kristin Zakariasen; Wotman, Stephen

    2008-10-01

    The commonly used methods of chart review, billing data summaries and practitioner self-reporting have not been examined for their ability to validly and reliably represent time use and service delivery in routine dental practice. A more thorough investigation of these data sources would provide insight into the appropriateness of each approach for measuring various clinical behaviors. The aim of this study was to assess the validity of commonly used methods such as dental chart review, billing data, or practitioner self-report compared with a 'gold standard' of information derived from direct observation of routine dental visits. A team of trained dental hygienists directly observed 3751 patient visits in 120 dental practices and recorded the behaviors and procedures performed by dentists and hygienists during patient contact time. Following each visit, charts and billing records were reviewed for the performed and billed procedures. Dental providers characterized their frequency of preventive service delivery through self-administered surveys. We standardized the observation and abstraction methods to obtain optimal measures from each of the multiple data sources. Multi-rater kappa coefficients were computed to monitor standardization, while sensitivity, specificity, and kappa coefficients were calculated to compare the various data sources with direct observation. Chart audits were more sensitive than billing data for all observed procedures and demonstrated higher agreement with directly observed data. Chart and billing records were not sensitive for several prevention-related tasks (oral cancer screening and oral hygiene instruction). Provider self-reports of preventive behaviors were always over-estimated compared with direct observation. Inter-method reliability kappa coefficients for 13 procedures ranged from 0.197 to 0.952. These concordance findings suggest that strengths and weaknesses of data collection sources should be considered when investigating

  4. The development and organizational format of a radiotherapy patient treatment chart

    International Nuclear Information System (INIS)

    Bynum, S.; McMurry, H.

    1989-01-01

    An important and time consuming responsibility of the Dosimetrist is to ensure and supervise accurate recording of delivered dose and treatment methods. With the rapidly growing complexity of technology, data, treatment protocol regimens and treatment methods, the need for accurate recording in a clearly arranged fashion has become imperative not only for daily patient treatment, but also for legal purposes. This paper describes the process of designing a patient treatment chart based on a review of charts already in use in various departments and aided by the input of all members of the Radiation Oncology treatment team at University of North Carolina, Chapel Hill

  5. Analysis of Lead and Zinc by Mercury-Free Potentiometric Stripping Analysis

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    1997-01-01

    A method is presented for trace-element analysis of lead and zinc by potentiometric stripping analysis (PSA) where both the glassy-carbon working electrode and the electrolyte are free of mercury. Analysis of zinc requires an activation procedure of the glassy-carbon electrode. The activation...... is performed by pre-concentrating zinc on glassy carbon at -1400 mV(SCE) in a mercury-free electrolyte containing 0.1 M HCl and 2 ppm Zn2+, followed by stripping at approx. -1050 mV. A linear relationship between stripping peak areas, recorded in the derivative mode, and concentration was found...

  6. Experimental evidence that wildflower strips increase pollinator visits to crops.

    Science.gov (United States)

    Feltham, Hannah; Park, Kirsty; Minderman, Jeroen; Goulson, Dave

    2015-08-01

    Wild bees provide a free and potentially diverse ecosystem service to farmers growing pollination-dependent crops. While many crops benefit from insect pollination, soft fruit crops, including strawberries are highly dependent on this ecosystem service to produce viable fruit. However, as a result of intensive farming practices and declining pollinator populations, farmers are increasingly turning to commercially reared bees to ensure that crops are adequately pollinated throughout the season. Wildflower strips are a commonly used measure aimed at the conservation of wild pollinators. It has been suggested that commercial crops may also benefit from the presence of noncrop flowers; however, the efficacy and economic benefits of sowing flower strips for crops remain relatively unstudied. In a study system that utilizes both wild and commercial pollinators, we test whether wildflower strips increase the number of visits to adjacent commercial strawberry crops by pollinating insects. We quantified this by experimentally sowing wildflower strips approximately 20 meters away from the crop and recording the number of pollinator visits to crops with, and without, flower strips. Between June and August 2013, we walked 292 crop transects at six farms in Scotland, recording a total of 2826 pollinators. On average, the frequency of pollinator visits was 25% higher for crops with adjacent flower strips compared to those without, with a combination of wild and commercial bumblebees (Bombus spp.) accounting for 67% of all pollinators observed. This effect was independent of other confounding effects, such as the number of flowers on the crop, date, and temperature. Synthesis and applications. This study provides evidence that soft fruit farmers can increase the number of pollinators that visit their crops by sowing inexpensive flower seed mixes nearby. By investing in this management option, farmers have the potential to increase and sustain pollinator populations over time.

  7. FusionCharts Beginner's Guide The Official Guide for FusionCharts Suite

    CERN Document Server

    Nadhani, Sanket; Bhattacharya, Shamasis

    2012-01-01

    The book is written as a practical, step-by-step guide to using FusionCharts Suite. The book not only teaches you the fundamentals and implementation of FusionCharts Suite, but also makes you the data visualization guru among your friends and colleagues by teaching how to select the right chart type and usability tips. Filled with examples, code samples and practical tips in a no-nonsense way, the book is a breeze to read.This book is both for beginners and advanced web developers who need to create interactive charts for their web applications. No previous knowledge of FusionCharts Suite is a

  8. 77 FR 23508 - Brass Sheet and Strip From France, Germany, Italy, and Japan

    Science.gov (United States)

    2012-04-19

    ...)] Brass Sheet and Strip From France, Germany, Italy, and Japan Determination On the basis of the record \\1... antidumping duty orders on brass sheet and strip from France, Germany, Italy, and Japan would be likely to... from France, Germany, Italy, and Japan: Investigation Nos. 731-TA-313, 314, 317, and 379 (Third Review...

  9. Model for prediction of strip temperature in hot strip steel mill

    International Nuclear Information System (INIS)

    Panjkovic, Vladimir

    2007-01-01

    Proper functioning of set-up models in a hot strip steel mill requires reliable prediction of strip temperature. Temperature prediction is particularly important for accurate calculation of rolling force because of strong dependence of yield stress and strip microstructure on temperature. A comprehensive model was developed to replace an obsolete model in the Western Port hot strip mill of BlueScope Steel. The new model predicts the strip temperature evolution from the roughing mill exit to the finishing mill exit. It takes into account the radiative and convective heat losses, forced flow boiling and film boiling of water at strip surface, deformation heat in the roll gap, frictional sliding heat, heat of scale formation and the heat transfer between strip and work rolls through an oxide layer. The significance of phase transformation was also investigated. Model was tested with plant measurements and benchmarked against other models in the literature, and its performance was very good

  10. Model for prediction of strip temperature in hot strip steel mill

    Energy Technology Data Exchange (ETDEWEB)

    Panjkovic, Vladimir [BlueScope Steel, TEOB, 1 Bayview Road, Hastings Vic. 3915 (Australia)]. E-mail: Vladimir.Panjkovic@BlueScopeSteel.com

    2007-10-15

    Proper functioning of set-up models in a hot strip steel mill requires reliable prediction of strip temperature. Temperature prediction is particularly important for accurate calculation of rolling force because of strong dependence of yield stress and strip microstructure on temperature. A comprehensive model was developed to replace an obsolete model in the Western Port hot strip mill of BlueScope Steel. The new model predicts the strip temperature evolution from the roughing mill exit to the finishing mill exit. It takes into account the radiative and convective heat losses, forced flow boiling and film boiling of water at strip surface, deformation heat in the roll gap, frictional sliding heat, heat of scale formation and the heat transfer between strip and work rolls through an oxide layer. The significance of phase transformation was also investigated. Model was tested with plant measurements and benchmarked against other models in the literature, and its performance was very good.

  11. Documentation of psychotropic PRN medication administration: An evaluation of electronic health records compared with paper charts and verbal reports.

    Science.gov (United States)

    Martin, Krystle; Ham, Elke; Hilton, Zoe

    2018-05-12

    To describe the documentation of pro re nata (PRN) medication for anxiety, and to compare documentation at two hospitals providing similar psychiatric services, one that used paper charts and another that used an electronic health record (EHR). We also assessed congruence between nursing documentation and verbal reports from staff about the PRN administration process. The ability to accurately document patients' symptoms and the care given is considered a core competency of the nursing profession (Wilkinson, 2007); however, researchers have found poor concordance between nursing notes and verbal reports or observations of events (e.g., De Marinis, Piredda, Pascarella et al., 2009) and considerable information missing (e.g., Marinis et al., 2010). Additionally, the administration of PRN medication has consistently been noted to be poorly documented (e.g., Baker, Lovell, & Harris, 2008). The project was a mixed method, two-phase study that collected data from two sites. In phase 1, nursing documentation of PRN medication administrations was reviewed in patient charts; phase 2 included verbal reports from staff about this practice. Nurses using EHR documented more information than those using paper charts, including the reason for PRN administration, who initiated the administration, and effectiveness. There were some differences between written and verbal reports, including whether potential side effects were explained to patients prior to PRN administration. We continue the calls for attention to be paid to improving the quality of nursing documentation. Our results support the shift to using EHR, yet not relying on this method completely to ensure comprehensiveness of documentation. Efforts to address the quality of documentation, particularly for PRN administration, are needed. This could be done through training, using structured report templates, and switching to electronic databases. This article is protected by copyright. All rights reserved. This article is

  12. Stand-alone Cosmic Muon Reconstruction Before Installation of the CMS Silicon Strip Tracker

    CERN Document Server

    Adam, W.; Dragicevic, M.; Friedl, M.; Fruhwirth, R.; Hansel, S.; Hrubec, J.; Krammer, M.; Oberegger, M.; Pernicka, M.; Schmid, S.; Stark, R.; Steininger, H.; Uhl, D.; Waltenberger, W.; Widl, E.; Van Mechelen, P.; Cardaci, M.; Beaumont, W.; de Langhe, E.; de Wolf, E.A.; Delmeire, E.; Hashemi, M.; Bouhali, O.; Charaf, O.; Clerbaux, B.; Dewulf, J.-P.; Elgammal, S.; Hammad, G.; de Lentdecker, G.; Marage, P.; Vander Velde, C.; Vanlaer, P.; Wickens, J.; Adler, V.; Devroede, O.; De Weirdt, S.; D'Hondt, J.; Goorens, R.; Heyninck, J.; Maes, J.; Mozer, Matthias Ulrich; Tavernier, S.; Van Lancker, L.; Van Mulders, P.; Villella, I.; Wastiels, C.; Bonnet, J.-L.; Bruno, G.; De Callatay, B.; Florins, B.; Giammanco, A.; Gregoire, G.; Keutgen, Th.; Kcira, D.; Lemaitre, V.; Michotte, D.; Militaru, O.; Piotrzkowski, K.; Quertermont, L.; Roberfroid, V.; Rouby, X.; Teyssier, D.; Daubie, E.; Anttila, E.; Czellar, S.; Engstrom, P.; Harkonen, J.; Karimaki, V.; Kostesmaa, J.; Kuronen, A.; Lampen, T.; Linden, T.; Luukka, P.-R.; Maenpaa, T.; Michal, S.; Tuominen, E.; Tuominiemi, J.; Ageron, M.; Baulieu, G.; Bonnevaux, A.; Boudoul, G.; Chabanat, E.; Chabert, E.; Chierici, R.; Contardo, D.; Della Negra, R.; Dupasquier, T.; Gelin, G.; Giraud, N.; Guillot, G.; Estre, N.; Haroutunian, R.; Lumb, N.; Perries, S.; Schirra, F.; Trocme, B.; Vanzetto, S.; Agram, J.-L.; Blaes, R.; Drouhin, F.; Ernenwein, J.-P.; Fontaine, J.-C.; Berst, J.-D.; Brom, J.-M.; Didierjean, F.; Goerlach, U.; Graehling, P.; Gross, L.; Hosselet, J.; Juillot, P.; Lounis, A.; Maazouzi, C.; Olivetto, C.; Strub, R.; Van Hove, P.; Anagnostou, G.; Brauer, R.; Esser, H.; Feld, L.; Karpinski, W.; Klein, K.; Kukulies, C.; Olzem, J.; Ostapchuk, A.; Pandoulas, D.; Pierschel, G.; Raupach, F.; Schael, S.; Schwering, G.; Sprenger, D.; Thomas, M.; Weber, M.; Wittmer, B.; Wlochal, M.; Beissel, F.; Bock, E.; Flugge, G.; Gillissen, C.; Hermanns, T.; Heydhausen, D.; Jahn, D.; Kaussen, G.; Linn, A.; Perchalla, L.; Poettgens, M.; Pooth, O.; Stahl, A.; Zoeller, M.H.; Buhmann, P.; Butz, E.; Flucke, G.; Hamdorf, R.; Hauk, J.; Klanner, R.; Pein, U.; Schleper, P.; Steinbruck, G.; Blum, P.; De Boer, W.; Dierlamm, A.; Dirkes, G.; Fahrer, M.; Frey, M.; Furgeri, A.; Hartmann, F.; Heier, S.; Hoffmann, K.-H.; Kaminski, J.; Ledermann, B.; Liamsuwan, T.; Muller, S.; Muller, Th.; Schilling, F.-P.; Simonis, H.-J.; Steck, P.; Zhukov, V.; Cariola, P.; De Robertis, G.; Ferorelli, R.; Fiore, L.; Preda, M.; Sala, G.; Silvestris, L.; Tempesta, P.; Zito, G.; Creanza, D.; De Filippis, N.; De Palma, M.; Giordano, D.; Maggi, G.; Manna, N.; My, S.; Selvaggi, G.; Albergo, S.; Chiorboli, M.; Costa, S.; Galanti, M.; Giudice, N.; Guardone, N.; Noto, F.; Potenza, R.; Saizu, M.A.; Sparti, V.; Sutera, C.; Tricomi, A.; Tuve, C.; Brianzi, M.; Civinini, C.; Maletta, F.; Manolescu, F.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Broccolo, B.; Ciulli, V.; D'Alessandro, R.; Focardi, E.; Frosali, S.; Genta, C.; Landi, G.; Lenzi, P.; Macchiolo, A.; Magini, N.; Parrini, G.; Scarlini, E.; Cerati, G.; Azzi, P.; Bacchetta, N.; Candelori, A.; Dorigo, T.; Kaminsky, A.; Karaevski, S.; Khomenkov, V.; Reznikov, S.; Tessaro, M.; Bisello, D.; De Mattia, M.; Giubilato, P.; Loreti, M.; Mattiazzo, S.; Nigro, M.; Paccagnella, A.; Pantano, D.; Pozzobon, N.; Tosi, M.; Bilei, G.M.; Checcucci, B.; Fano, L.; Servoli, L.; Ambroglini, F.; Babucci, E.; Benedetti, D.; Biasini, M.; Caponeri, B.; Covarelli, R.; Giorgi, M.; Lariccia, P.; Mantovani, G.; Marcantonini, M.; Postolache, V.; Santocchia, A.; Spiga, D.; Bagliesi, G.; Balestri, G.; Berretta, L.; Bianucci, S.; Boccali, T.; Bosi, F.; Bracci, F.; Castaldi, R.; Ceccanti, M.; Cecchi, R.; Cerri, C.; Cucoanes, A .S.; Dell'Orso, R.; Dobur, D.; Dutta, S.; Giassi, A.; Giusti, S.; Kartashov, D.; Kraan, A.; Lomtadze, T.; Lungu, G.A.; Magazzu, G.; Mammini, P.; Mariani, F.; Martinelli, G.; Moggi, A.; Palla, F.; Palmonari, F.; Petragnani, G.; Profeti, A.; Raffaelli, F.; Rizzi, D.; Sanguinetti, G.; Sarkar, S.; Sentenac, D.; Serban, A.T.; Slav, A.; Soldani, A.; Spagnolo, P.; Tenchini, R.; Tolaini, S.; Venturi, A.; Verdini, P.G.; Vos, M.; Zaccarelli, L.; Avanzini, C.; Basti, A.; Benucci, L.; Bocci, A.; Cazzola, U.; Fiori, F.; Linari, S.; Massa, M.; Messineo, A.; Segneri, G.; Tonelli, G.; Azzurri, P.; Bernardini, J.; Borrello, L.; Calzolari, F.; Foa, L.; Gennai, S.; Ligabue, F.; Petrucciani, G.; Rizzi, A.; Yang, Z.; Benotto, F.; Demaria, N.; Dumitrache, F.; Farano, R.; Borgia, M.A.; Castello, R.; Costa, M.; Migliore, E.; Romero, A.; Abbaneo, D.; Abbas, M.; Ahmed, I.; Akhtar, I.; Albert, E.; Bloch, C.; Breuker, H.; Butt, S.; Buchmuller, O.; Cattai, A.; Delaere, C.; Delattre, M.; Edera, L.M.; Engstrom, P.; Eppard, M.; Gateau, M.; Gill, K.; Giolo-Nicollerat, A.-S.; Grabit, R.; Honma, A.; Huhtinen, M.; Kloukinas, K.; Kortesmaa, J.; Kottelat, L.J.; Kuronen, A.; Leonardo, N.; Ljuslin, C.; Mannelli, M.; Masetti, L.; Marchioro, A.; Mersi, S.; Michal, S.; Mirabito, L.; Muffat-Joly, J.; Onnela, A.; Paillard, C.; Pal, I.; Pernot, J.F.; Petagna, P.; Petit, P.; Piccut, C.; Pioppi, M.; Postema, H.; Ranieri, R.; Ricci, D.; Rolandi, G.; Ronga, F.; Sigaud, C.; Syed, A.; Siegrist, P.; Tropea, P.; Troska, J.; Tsirou, A.; Vander Donckt, M.; Vasey, F.; Alagoz, E.; Amsler, Claude; Chiochia, V.; Regenfus, Christian; Robmann, P.; Rochet, J.; Rommerskirchen, T.; Schmidt, A.; Steiner, S.; Wilke, L.; Church, I.; Cole, J.; Coughlan, J.; Gay, A.; Taghavi, S.; Tomalin, I.; Bainbridge, R.; Cripps, N.; Fulcher, J.; Hall, G.; Noy, M.; Pesaresi, M.; Radicci, V.; Raymond, D.M.; Sharp, P.; Stoye, M.; Wingham, M.; Zorba, O.; Goitom, I.; Hobson, P.R.; Reid, I.; Teodorescu, L.; Hanson, G.; Jeng, G.-Y.; Liu, H.; Pasztor, G.; Satpathy, A.; Stringer, R.; Mangano, B.; Affolder, K.; Affolder, T.; Allen, A.; Barge, D.; Burke, S.; Callahan, D.; Campagnari, C.; Crook, A.; D'Alfonso, M.; Dietch, J.; Garberson, Jeffrey Ford; Hale, D.; Incandela, H.; Incandela, J.; Jaditz, S.; Kalavase, P.; Kreyer, S.; Kyre, S.; Lamb, J.; Mc Guinness, C.; Mills, C.; Nguyen, H.; Nikolic, M.; Lowette, S.; Rebassoo, F.; Ribnik, J.; Richman, J.; Rubinstein, N.; Sanhueza, S.; Shah, Y.; Simms, L.; Staszak, D.; Stoner, J.; Stuart, D.; Swain, S.; Vlimant, J.-R.; White, D.; Ulmer, K.A.; Wagner, S.R.; Bagby, L.; Bhat, P.C.; Burkett, K.; Cihangir, S.; Gutsche, O.; Jensen, H.; Johnson, M.; Luzhetskiy, N.; Mason, D.; Miao, T.; Moccia, S.; Noeding, C.; Ronzhin, A.; Skup, E.; Spalding, W.J.; Spiegel, L.; Tkaczyk, S.; Yumiceva, F.; Zatserklyaniy, A.; Zerev, E.; Anghel, I.; Bazterra, V.E.; Gerber, C.E.; Khalatian, S.; Shabalina, E.; Baringer, Philip S.; Bean, A.; Chen, J.; Hinchey, C.; Martin, C.; Moulik, T.; Robinson, R.; Gritsan, A.V.; Lae, C.K.; Tran, N.V.; Everaerts, P.; Hahn, K.A.; Harris, P.; Nahn, S.; Rudolph, M.; Sung, K.; Betchart, B.; Demina, R.; Gotra, Y.; Korjenevski, S.; Miner, D.; Orbaker, D.; Christofek, L.; Hooper, R.; Landsberg, G.; Nguyen, D.; Narain, M.; Speer, T.; Tsang, K.V.

    2009-01-01

    The subsystems of the CMS silicon strip tracker were integrated and commissioned at the Tracker Integration Facility (TIF) in the period from November 2006 to July 2007. As part of the commissioning, large samples of cosmic ray data were recorded under various running conditions in the absence of a magnetic field. Cosmic rays detected by scintillation counters were used to trigger the readout of up to 15% of the final silicon strip detector, and over 4.7 million events were recorded. This document describes the cosmic track reconstruction and presents results on the performance of track and hit reconstruction as from dedicated analyses.

  13. Growth Charts (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Growth Charts KidsHealth / For Parents / Growth Charts What's in ... Problem? Print en español Tablas de crecimiento About Growth Charts Look at any class picture, and you' ...

  14. Performance studies of the CMS Strip Tracker before installation

    CERN Document Server

    Adam, Wolfgang; Dragicevic, Marko; Friedl, Markus; Fruhwirth, R; Hansel, S; Hrubec, Josef; Krammer, Manfred; Oberegger, Margit; Pernicka, Manfred; Schmid, Siegfried; Stark, Roland; Steininger, Helmut; Uhl, Dieter; Waltenberger, Wolfgang; Widl, Edmund; Van Mechelen, Pierre; Cardaci, Marco; Beaumont, Willem; de Langhe, Eric; de Wolf, Eddi A; Delmeire, Evelyne; Hashemi, Majid; Bouhali, Othmane; Charaf, Otman; Clerbaux, Barbara; Dewulf, Jean-Paul; Elgammal, Sherif; Hammad, Gregory Habib; de Lentdecker, Gilles; Marage, Pierre Edouard; Vander Velde, Catherine; Vanlaer, Pascal; Wickens, John; Adler, Volker; Devroede, Olivier; De Weirdt, Stijn; D'Hondt, Jorgen; Goorens, Robert; Heyninck, Jan; Maes, Joris; Mozer, Matthias Ulrich; Tavernier, Stefaan; Van Lancker, Luc; Van Mulders, Petra; Villella, Ilaria; Wastiels, C; Bonnet, Jean-Luc; Bruno, Giacomo; De Callatay, Bernard; Florins, Benoit; Giammanco, Andrea; Gregoire, Ghislain; Keutgen, Thomas; Kcira, Dorian; Lemaitre, Vincent; Michotte, Daniel; Militaru, Otilia; Piotrzkowski, Krzysztof; Quertermont, L; Roberfroid, Vincent; Rouby, Xavier; Teyssier, Daniel; Daubie, Evelyne; Anttila, Erkki; Czellar, Sandor; Engstrom, Pauli; Harkonen, J; Karimaki, V; Kostesmaa, J; Kuronen, Auli; Lampen, Tapio; Linden, Tomas; Luukka, Panja-Riina; Maenpaa, T; Michal, Sebastien; Tuominen, Eija; Tuominiemi, Jorma; Ageron, Michel; Baulieu, Guillaume; Bonnevaux, Alain; Boudoul, Gaelle; Chabanat, Eric; Chabert, Eric Christian; Chierici, Roberto; Contardo, Didier; Della Negra, Rodolphe; Dupasquier, Thierry; Gelin, Georges; Giraud, Noël; Guillot, Gérard; Estre, Nicolas; Haroutunian, Roger; Lumb, Nicholas; Perries, Stephane; Schirra, Florent; Trocme, Benjamin; Vanzetto, Sylvain; Agram, Jean-Laurent; Blaes, Reiner; Drouhin, Frédéric; Ernenwein, Jean-Pierre; Fontaine, Jean-Charles; Berst, Jean-Daniel; Brom, Jean-Marie; Didierjean, Francois; Goerlach, Ulrich; Graehling, Philippe; Gross, Laurent; Hosselet, J; Juillot, Pierre; Lounis, Abdenour; Maazouzi, Chaker; Olivetto, Christian; Strub, Roger; Van Hove, Pierre; Anagnostou, Georgios; Brauer, Richard; Esser, Hans; Feld, Lutz; Karpinski, Waclaw; Klein, Katja; Kukulies, Christoph; Olzem, Jan; Ostapchuk, Andrey; Pandoulas, Demetrios; Pierschel, Gerhard; Raupach, Frank; Schael, Stefan; Schwering, Georg; Sprenger, Daniel; Thomas, Maarten; Weber, Markus; Wittmer, Bruno; Wlochal, Michael; Beissel, Franz; Bock, E; Flugge, G; Gillissen, C; Hermanns, Thomas; Heydhausen, Dirk; Jahn, Dieter; Kaussen, Gordon; Linn, Alexander; Perchalla, Lars; Poettgens, Michael; Pooth, Oliver; Stahl, Achim; Zoeller, Marc Henning; Buhmann, Peter; Butz, Erik; Flucke, Gero; Hamdorf, Richard Helmut; Hauk, Johannes; Klanner, Robert; Pein, Uwe; Schleper, Peter; Steinbruck, G; Blum, P; De Boer, Wim; Dierlamm, Alexander; Dirkes, Guido; Fahrer, Manuel; Frey, Martin; Furgeri, Alexander; Hartmann, Frank; Heier, Stefan; Hoffmann, Karl-Heinz; Kaminski, Jochen; Ledermann, Bernhard; Liamsuwan, Thiansin; Muller, S; Muller, Th; Schilling, Frank-Peter; Simonis, Hans-Jürgen; Steck, Pia; Zhukov, Valery; Cariola, P; De Robertis, Giuseppe; Ferorelli, Raffaele; Fiore, Luigi; Preda, M; Sala, Giuliano; Silvestris, Lucia; Tempesta, Paolo; Zito, Giuseppe; Creanza, Donato; De Filippis, Nicola; De Palma, Mauro; Giordano, Domenico; Maggi, Giorgio; Manna, Norman; My, Salvatore; Selvaggi, Giovanna; Albergo, Sebastiano; Chiorboli, Massimiliano; Costa, Salvatore; Galanti, Mario; Giudice, Nunzio; Guardone, Nunzio; Noto, Francesco; Potenza, Renato; Saizu, Mirela Angela; Sparti, V; Sutera, Concetta; Tricomi, Alessia; Tuve, Cristina; Brianzi, Mirko; Civinini, Carlo; Maletta, Fernando; Manolescu, Florentina; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Broccolo, B; Ciulli, Vitaliano; D'Alessandro, Raffaello; Focardi, Ettore; Frosali, Simone; Genta, Chiara; Landi, Gregorio; Lenzi, Piergiulio; Macchiolo, Anna; Magini, Nicolo; Parrini, Giuliano; Scarlini, Enrico; Cerati, Giuseppe Benedetto; Azzi, Patrizia; Bacchetta, Nicola; Candelori, Andrea; Dorigo, Tommaso; Kaminsky, A; Karaevski, S; Khomenkov, Volodymyr; Reznikov, Sergey; Tessaro, Mario; Bisello, Dario; De Mattia, Marco; Giubilato, Piero; Loreti, Maurizio; Mattiazzo, Serena; Nigro, Massimo; Paccagnella, Alessandro; Pantano, Devis; Pozzobon, Nicola; Tosi, Mia; Bilei, Gian Mario; Checcucci, Bruno; Fano, Livio; Servoli, Leonello; Ambroglini, Filippo; Babucci, Ezio; Benedetti, Daniele; Biasini, Maurizio; Caponeri, Benedetta; Covarelli, Roberto; Giorgi, Marco; Lariccia, Paolo; Mantovani, Giancarlo; Marcantonini, Marta; Postolache, Vasile; Santocchia, Attilio; Spiga, Daniele; Bagliesi, Giuseppe; Balestri, Gabriele; Berretta, Luca; Bianucci, S; Boccali, Tommaso; Bosi, Filippo; Bracci, Fabrizio; Castaldi, Rino; Ceccanti, Marco; Cecchi, Roberto; Cerri, Claudio; Cucoanes, Andi Sebastian; Dell'Orso, Roberto; Dobur, Didar; Dutta, Suchandra; Giassi, Alessandro; Giusti, Simone; Kartashov, Dmitry; Kraan, Aafke; Lomtadze, Teimuraz; Lungu, George-Adrian; Magazzu, Guido; Mammini, Paolo; Mariani, Filippo; Martinelli, Giovanni; Moggi, Andrea; Palla, Fabrizio; Palmonari, Francesco; Petragnani, Giulio; Profeti, Alessandro; Raffaelli, Fabrizio; Rizzi, Domenico; Sanguinetti, Giulio; Sarkar, Subir; Sentenac, Daniel; Serban, Alin Titus; Slav, Adrian; Soldani, A; Spagnolo, Paolo; Tenchini, Roberto; Tolaini, Sergio; Venturi, Andrea; Verdini, Piero Giorgio; Vos, Marcel; Zaccarelli, Luciano; Avanzini, Carlo; Basti, Andrea; Benucci, Leonardo; Bocci, Andrea; Cazzola, Ugo; Fiori, Francesco; Linari, Stefano; Massa, Maurizio; Messineo, Alberto; Segneri, Gabriele; Tonelli, Guido; Azzurri, Paolo; Bernardini, Jacopo; Borrello, Laura; Calzolari, Federico; Foa, Lorenzo; Gennai, Simone; Ligabue, Franco; Petrucciani, Giovanni; Rizzi, Andrea; Yang, Zong-Chang; Benotto, Franco; Demaria, Natale; Dumitrache, Floarea; Farano, R; Borgia, Maria Assunta; Castello, Roberto; Costa, Marco; Migliore, Ernesto; Romero, Alessandra; Abbaneo, Duccio; Abbas, M; Ahmed, Ijaz; Akhtar, I; Albert, Eric; Bloch, Christoph; Breuker, Horst; Butt, Shahid Aleem; Buchmuller, Oliver; Cattai, Ariella; Delaere, Christophe; Delattre, Michel; Edera, Laura Maria; Engstrom, Pauli; Eppard, Michael; Gateau, Maryline; Gill, Karl; Giolo-Nicollerat, Anne-Sylvie; Grabit, Robert; Honma, Alan; Huhtinen, Mika; Kloukinas, Kostas; Kortesmaa, Jarmo; Kottelat, Luc-Joseph; Kuronen, Auli; Leonardo, Nuno; Ljuslin, Christer; Mannelli, Marcello; Masetti, Lorenzo; Marchioro, Alessandro; Mersi, Stefano; Michal, Sebastien; Mirabito, Laurent; Muffat-Joly, Jeannine; Onnela, Antti; Paillard, Christian; Pal, Imre; Pernot, Jean-Francois; Petagna, Paolo; Petit, Patrick; Piccut, C; Pioppi, Michele; Postema, Hans; Ranieri, Riccardo; Ricci, Daniel; Rolandi, Gigi; Ronga, Frederic Jean; Sigaud, Christophe; Syed, A; Siegrist, Patrice; Tropea, Paola; Troska, Jan; Tsirou, Andromachi; Vander Donckt, Muriel; Vasey, François; Alagoz, Enver; Amsler, Claude; Chiochia, Vincenzo; Regenfus, Christian; Robmann, Peter; Rochet, Jacky; Rommerskirchen, Tanja; Schmidt, Alexander; Steiner, Stefan; Wilke, Lotte; Church, Ivan; Cole, Joanne; Coughlan, John A; Gay, Arnaud; Taghavi, S; Tomalin, Ian R; Bainbridge, Robert; Cripps, Nicholas; Fulcher, Jonathan; Hall, Geoffrey; Noy, Matthew; Pesaresi, Mark; Radicci, Valeria; Raymond, David Mark; Sharp, Peter; Stoye, Markus; Wingham, Matthew; Zorba, Osman; Goitom, Israel; Hobson, Peter R; Reid, Ivan; Teodorescu, Liliana; Hanson, Gail; Jeng, Geng-Yuan; Liu, Haidong; Pasztor, Gabriella; Satpathy, Asish; Stringer, Robert; Mangano, Boris; Affolder, K; Affolder, T; Allen, Andrea; Barge, Derek; Burke, Samuel; Callahan, D; Campagnari, Claudio; Crook, A; D'Alfonso, Mariarosaria; Dietch, J; Garberson, Jeffrey; Hale, David; Incandela, H; Incandela, Joe; Jaditz, Stephen; Kalavase, Puneeth; Kreyer, Steven Lawrence; Kyre, Susanne; Lamb, James; Mc Guinness, C; Mills, C; Nguyen, Harold; Nikolic, Milan; Lowette, Steven; Rebassoo, Finn; Ribnik, Jacob; Richman, Jeffrey; Rubinstein, Noah; Sanhueza, S; Shah, Yousaf Syed; Simms, L; Staszak, D; Stoner, J; Stuart, David; Swain, Sanjay Kumar; Vlimant, Jean-Roch; White, Dean; Ulmer, Keith; Wagner, Stephen Robert; Bagby, Linda; Bhat, Pushpalatha C; Burkett, Kevin; Cihangir, Selcuk; Gutsche, Oliver; Jensen, Hans; Johnson, Mark; Luzhetskiy, Nikolay; Mason, David; Miao, Ting; Moccia, Stefano; Noeding, Carsten; Ronzhin, Anatoly; Skup, Ewa; Spalding, William J; Spiegel, Leonard; Tkaczyk, Slawek; Yumiceva, Francisco; Zatserklyaniy, Andriy; Zerev, E; Anghel, Ioana Maria; Bazterra, Victor Eduardo; Gerber, Cecilia Elena; Khalatian, S; Shabalina, Elizaveta; Baringer, Philip; Bean, Alice; Chen, Jie; Hinchey, Carl Louis; Martin, Christophe; Moulik, Tania; Robinson, Richard; Gritsan, Andrei; Lae, Chung Khim; Tran, Nhan Viet; Everaerts, Pieter; Hahn, Kristan Allan; Harris, Philip; Nahn, Steve; Rudolph, Matthew; Sung, Kevin; Betchart, Burton; Demina, Regina; Gotra, Yury; Korjenevski, Sergey; Miner, Daniel Carl; Orbaker, Douglas; Christofek, Leonard; Hooper, Ryan; Landsberg, Greg; Nguyen, Duong; Narain, Meenakshi; Speer, Thomas; Tsang, Ka Vang

    2009-01-01

    In March 2007 the assembly of the Silicon Strip Tracker was completed at the Tracker Integration Facility at CERN. Nearly 15% of the detector was instrumented using cables, fiber optics, power supplies, and electronics intended for the operation at the LHC. A local chiller was used to circulate the coolant for low temperature operation. In order to understand the efficiency and alignment of the strip tracker modules, a cosmic ray trigger was implemented. From March through July 4.5 million triggers were recorded. This period, referred to as the Sector Test, provided practical experience with the operation of the Tracker, especially safety, data acquisition, power, and cooling systems. This paper describes the performance of the strip system during the Sector Test, which consisted of five distinct periods defined by the coolant temperature. Significant emphasis is placed on comparisons between the data and results from Monte Carlo studies.

  15. Surface Prognostic Charts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Surface Prognostic Charts are historical surface prognostic (forecast) charts created by the United States Weather Bureau. They include fronts, isobars, cloud, and...

  16. Reason for hospital admission: a pilot study comparing patient statements with chart reports.

    Science.gov (United States)

    Berger, Zackary; Dembitzer, Anne; Beach, Mary Catherine

    2013-01-01

    Providers and patients bring different understandings of health and disease to their encounters in the hospital setting. The literature to date only infrequently addresses patient and provider concordance on the reported reason for hospitalization, that is, whether they express this reason in similar ways. An agreement or common ground between such understandings can serve as a basis for future communication regarding an illness and its treatment. We interviewed a convenience sample of patients on the medical wards of an urban academic medical center. We asked subjects to state the reason why their doctors admitted them to the hospital, and then compared their statement with the reason in the medical record. We defined concordance on reported reason for hospitalization as agreement between the patient's report and the reason abstracted from the chart. We interviewed and abstracted chart data from a total of 46 subjects. Concordance on reported reason for hospitalization was present in 24 (52%) and discordance in 17 (37%); 5 patients (11%) could not give any reason for their hospitalization. Among the 17 patients whose report was discordant with their chart, 12 (71%) reported a different organ system than was recorded in the chart. A significant proportion of medical inpatients could not state their physicians' reason for admission. In addition, patients who identify a different reason for hospitalization than the chart often give a different organ system altogether. Providers should explore patient understanding of the reason for their hospitalization to facilitate communication and shared decision making.

  17. Quantitative comparison of 3 enamel-stripping devices in vitro: how precisely can we strip teeth?

    Science.gov (United States)

    Johner, Alexander Marc; Pandis, Nikolaos; Dudic, Alexander; Kiliaridis, Stavros

    2013-04-01

    In this in-vitro study, we aimed to investigate the predictability of the expected amount of stripping using 3 common stripping devices on premolars. One hundred eighty extracted premolars were mounted and aligned in silicone. Tooth mobility was tested with Periotest (Medizintechnik Gulden, Modautal, Germany) (8.3 ± 2.8 units). The selected methods for interproximal enamel reduction were hand-pulled strips (Horico, Hapf Ringleb & Company, Berlin, Germany), oscillating segmental disks (O-drive-OD 30; KaVo Dental, Biberach, Germany), and motor-driven abrasive strips (Orthofile; SDC Switzerland, Lugano-Grancia, Switzerland). With each device, the operator intended to strip 0.1, 0.2, 0.3, or 0.4 mm on the mesial side of 15 teeth. The teeth were scanned before and after stripping with a 3-dimensional laser scanner. Superposition and measurement of stripped enamel on the most mesial point of the tooth were conducted with Viewbox software (dHal Software, Kifissia, Greece). The Wilcoxon signed rank test and the Kruskal-Wallis test were applied; statistical significance was set at alpha ≤ 0.05. Large variations between the intended and the actual amounts of stripped enamel, and between stripping procedures, were observed. Significant differences were found at 0.1 mm of intended stripping (P ≤ 0.05) for the hand-pulled method and at 0.4 mm of intended stripping (P ≤ 0.001 to P = 0.05) for all methods. For all scenarios of enamel reduction, the actual amount of stripping was less than the predetermined and expected amount of stripping. The Kruskal-Wallis analysis showed no significant differences between the 3 methods. There were variations in the stripped amounts of enamel, and the stripping technique did not appear to be a significant predictor of the actual amount of enamel reduction. In most cases, actual stripping was less than the intended amount of enamel reduction. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights

  18. Silicon strip detector qualification for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kaussen, Gordon

    2008-10-06

    To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The performance of the participating two shells of the TIB, four rods of the TOB and two petals of the TEC (representing about 1% of the final strip tracker) could be studied in different magnetic fields over a period of approximately two month using cosmic muon signals. The last test before inserting the tracker in the CMS experiment was the Tracker Slice Test performed in spring/summer 2007 at the Tracker Integration Facility (TIF) at CERN after installing all subdetectors in the tracker support tube. Approximately 25% of the strip tracker +z side was powered and read out using a cosmic ray trigger built up of scintillation counters. In total, about 5 million muon events were recorded under various operating conditions. These events together with results from commissioning runs were used to study the detector response like cluster charges, signal-to-noise ratios and single strip noise behaviour as well as to identify faulty channels which turned out to be in the order of a few per mille. The performance of the silicon strip tracker during these different construction stages is discussed in this thesis with a special emphasis on the tracker end caps. (orig.)

  19. Silicon strip detector qualification for the CMS experiment

    International Nuclear Information System (INIS)

    Kaussen, Gordon

    2008-01-01

    To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The performance of the participating two shells of the TIB, four rods of the TOB and two petals of the TEC (representing about 1% of the final strip tracker) could be studied in different magnetic fields over a period of approximately two month using cosmic muon signals. The last test before inserting the tracker in the CMS experiment was the Tracker Slice Test performed in spring/summer 2007 at the Tracker Integration Facility (TIF) at CERN after installing all subdetectors in the tracker support tube. Approximately 25% of the strip tracker +z side was powered and read out using a cosmic ray trigger built up of scintillation counters. In total, about 5 million muon events were recorded under various operating conditions. These events together with results from commissioning runs were used to study the detector response like cluster charges, signal-to-noise ratios and single strip noise behaviour as well as to identify faulty channels which turned out to be in the order of a few per mille. The performance of the silicon strip tracker during these different construction stages is discussed in this thesis with a special emphasis on the tracker end caps. (orig.)

  20. 360-degrees profilometry using strip-light projection coupled to Fourier phase-demodulation.

    Science.gov (United States)

    Servin, Manuel; Padilla, Moises; Garnica, Guillermo

    2016-01-11

    360 degrees (360°) digitalization of three dimensional (3D) solids using a projected light-strip is a well-established technique in academic and commercial profilometers. These profilometers project a light-strip over the digitizing solid while the solid is rotated a full revolution or 360-degrees. Then, a computer program typically extracts the centroid of this light-strip, and by triangulation one obtains the shape of the solid. Here instead of using intensity-based light-strip centroid estimation, we propose to use Fourier phase-demodulation for 360° solid digitalization. The advantage of Fourier demodulation over strip-centroid estimation is that the accuracy of phase-demodulation linearly-increases with the fringe density, while in strip-light the centroid-estimation errors are independent. Here we proposed first to construct a carrier-frequency fringe-pattern by closely adding the individual light-strip images recorded while the solid is being rotated. Next, this high-density fringe-pattern is phase-demodulated using the standard Fourier technique. To test the feasibility of this Fourier demodulation approach, we have digitized two solids with increasing topographic complexity: a Rubik's cube and a plastic model of a human-skull. According to our results, phase demodulation based on the Fourier technique is less noisy than triangulation based on centroid light-strip estimation. Moreover, Fourier demodulation also provides the amplitude of the analytic signal which is a valuable information for the visualization of surface details.

  1. APPLICATION OF U-CHART AND C-CHART IN TECHNOLOGICAL PROCESS OF PRIMARY WOOD PROCESSING

    Directory of Open Access Journals (Sweden)

    Damjan Stanojević

    2014-01-01

    Full Text Available Control charts are statistical methods of quality control. Basically it is a graph where the abscissa represents the order of control, and the ordinate is marked with parameter values, which are controled by samples over a certain size. Using charts determine varying quality and also related the stability and capacity of the production process in relation to the established control limits. Dr. Schuchardt, which can be regarded as the creator of control charts, says that their mission: to maintain the production process in a state of control, to lead the production process into a state of control, to show that the state of control has been achieved. According to Dr. Schuchardt „for a phenomenon is said to be controlled if based on current data we can predict, at least within certain limits, how the phenomenon will change in the future. Here, under certain prediction within limits means that we can determine, at least approximately, the probability that the phenomenon is found within the given limits“. Control charts for attribute quality characteristics are: p- control chart, m- control chart, u- control chart, c- control chart.

  2. Stripping Voltammetry

    Science.gov (United States)

    Lovrić, Milivoj

    Electrochemical stripping means the oxidative or reductive removal of atoms, ions, or compounds from an electrode surface (or from the electrode body, as in the case of liquid mercury electrodes with dissolved metals) [1-5]. In general, these atoms, ions, or compounds have been preliminarily immobilized on the surface of an inert electrode (or within it) as the result of a preconcentration step, while the products of the electrochemical stripping will dissolve in the electrolytic solution. Often the product of the electrochemical stripping is identical to the analyte before the preconcentration. However, there are exemptions to these rules. Electroanalytical stripping methods comprise two steps: first, the accumulation of a dissolved analyte onto, or in, the working electrode, and, second, the subsequent stripping of the accumulated substance by a voltammetric [3, 5], potentiometric [6, 7], or coulometric [8] technique. In stripping voltammetry, the condition is that there are two independent linear relationships: the first one between the activity of accumulated substance and the concentration of analyte in the sample, and the second between the maximum stripping current and the accumulated substance activity. Hence, a cumulative linear relationship between the maximum response and the analyte concentration exists. However, the electrode capacity for the analyte accumulation is limited and the condition of linearity is satisfied only well below the electrode saturation. For this reason, stripping voltammetry is used mainly in trace analysis. The limit of detection depends on the factor of proportionality between the activity of the accumulated substance and the bulk concentration of the analyte. This factor is a constant in the case of a chemical accumulation, but for electrochemical accumulation it depends on the electrode potential. The factor of proportionality between the maximum stripping current and the analyte concentration is rarely known exactly. In fact

  3. A comparative study of ICU patient diaries vs. hospital charts

    DEFF Research Database (Denmark)

    Egerod, Ingrid; Christensen, Doris

    2010-01-01

    Intensive care survivors often suffer from memory disorders, and some go on to develop anxiety, depression, and posttraumatic stress. Since the 1980s nurses have written diaries for intensive care patients to help them understand their illness and come to terms with their experiences after...... discharge. The central question we posed in this study was: Why do nurses write diaries in addition to conventional charting in the medical record? To answer this question, we compared intensive care diaries and hospital charts using textual analysis and narrative theory. The aims of our study were...... to compare patient diaries and hospital charts to explore (a) what each documentation instrument has to offer patients in their quest to make sense of their illness, and (b) why it is worthwhile for nurses to sustain the practice of writing diaries. The study findings show that the diary is coherent...

  4. Low amplitude rhythmic contraction frequency in human detrusor strips correlates with phasic intravesical pressure waves.

    Science.gov (United States)

    Colhoun, Andrew F; Speich, John E; Cooley, Lauren F; Bell, Eugene D; Barbee, R Wayne; Guruli, Georgi; Ratz, Paul H; Klausner, Adam P

    2017-08-01

    Low amplitude rhythmic contractions (LARC) occur in detrusor smooth muscle and may play a role in storage disorders such as overactive bladder and detrusor overactivity. The purpose of this study was to determine whether LARC frequencies identified in vitro from strips of human urinary bladder tissue correlate with in vivo LARC frequencies, visualized as phasic intravesical pressure (p ves ) waves during urodynamics (UD). After IRB approval, fresh strips of human urinary bladder were obtained from patients. LARC was recorded with tissue strips at low tension (rhythmic frequency similar to the in vitro LARC frequency quantified in human urinary bladder tissue strips. Further refinements of this technique may help identify subsets of individuals with LARC-mediated storage disorders.

  5. 40 CFR 53.32 - Test procedures for methods for SO2, CO, O3, and NO2.

    Science.gov (United States)

    2010-07-01

    ... appropriate time intervals such that trend plots similar to a strip chart recording may be constructed with a...)(2), effective Aug. 23, 2010. For the convenience of the user, the revised text is set forth as...

  6. ICAO Aeronautical chart production: aerodrome obstruction charts from small–format aerial digital imagery

    Directory of Open Access Journals (Sweden)

    Jorge Padro Molina

    2012-11-01

    Full Text Available Aeronautical charts and aerodrome obstruction charts, provide information about obstacles around the airport, so pilots and air traffic controllers can comply with the procedures and limitations of its utilization. Safety in aviation demands updated and precise aeronautical charts production, adopting the standards of the International Civil Aviation Organization (ICAO. In this paper the methodology employed to generate obstruction charts for five airports in Mexico, using aerial digital imagery obtained with small–format cameras, is described. Through two aerial surveys on each airport, from 10 000 and 5 000 feet above ground level, two orthomosaics were generated covering the airport influence area, the runway, and the obstacle limitation surfaces: approach/Take–off climb, transitional, inner horizontal, and conical. Using stereopair photointerpretation most of the obstacles were identified, and by means of the orthomosaics; aerodrome charts, and aerodrome obstruction charts types A, B and C, were generated. Using satellite geodetic receivers, 18 points were surveyed on each runway in order to obtain its dimensions, and to establish ground control points for mosaics generation. Throughout detailed field work, height and location of the obstacles were verified, and finally, after several reviewing processes by aeronautical authorities, generation of ICAO charts was concluded when all airport maps were integrated in a Geographical Information System.

  7. [Ophthalmologic reading charts : Part 2: Current logarithmically scaled reading charts].

    Science.gov (United States)

    Radner, W

    2016-12-01

    To analyze currently available reading charts regarding print size, logarithmic print size progression, and the background of test-item standardization. For the present study, the following logarithmically scaled reading charts were investigated using a measuring microscope (iNexis VMA 2520; Nikon, Tokyo): Eschenbach, Zeiss, OCULUS, MNREAD (Minnesota Near Reading Test), Colenbrander, and RADNER. Calculations were made according to EN-ISO 8596 and the International Research Council recommendations. Modern reading charts and cards exhibit a logarithmic progression of print sizes. The RADNER reading charts comprise four different cards with standardized test items (sentence optotypes), a well-defined stop criterion, accurate letter sizes, and a high print quality. Numbers and Landolt rings are also given in the booklet. The OCULUS cards have currently been reissued according to recent standards and also exhibit a high print quality. In addition to letters, numbers, Landolt rings, and examples taken from a timetable and the telephone book, sheet music is also offered. The Colenbrander cards use short sentences of 44 characters, including spaces, and exhibit inaccuracy at smaller letter sizes, as do the MNREAD cards. The MNREAD cards use sentences of 60 characters, including spaces, and have a high print quality. Modern reading charts show that international standards can be achieved with test items similar to optotypes, by using recent technology and developing new concepts of test-item standardization. Accurate print sizes, high print quality, and a logarithmic progression should become the minimum requirements for reading charts and reading cards in ophthalmology.

  8. Recognition versus Resolution: a Comparison of Visual Acuity Results Using Two Alternative Test Chart Optotype

    Directory of Open Access Journals (Sweden)

    Jonathan S. Pointer

    2008-01-01

    Conclusions: For normally sighted subjects wearing an optimal refractive correction, a bias was recorded in favour of recognition over resolution acuity: the clinical difference amounted to approximately 40% of one logMAR chart line, with similar high repeatability for either chart optotype. We conclude that the assumption of clinical equivalence between letter and Landolt acuity is reasonable under optimum test conditions.

  9. Spectral Imaging of Portolan Charts

    Science.gov (United States)

    France, Fenella G.; Wilson, Meghan A.; Ghez, Anita

    2018-05-01

    Spectral imaging of Portolan Charts, early nautical charts, provided extensive new information about their construction and creation. The origins of the portolan chart style have been a continual source of perplexity to numerous generations of cartographic historians. The spectral imaging system utilized incorporates a 50 megapixel mono-chrome camera with light emitting diode (LED) illumination panels that cover the range from 365 nm to 1050 nm to capture visible and non-visible information. There is little known about how portolan charts evolved, and what influenced their creation. These early nautical charts began as working navigational tools of medieval mariners, initially made in the 1300s in Italy, Portugal and Spain; however the origin and development of the portolan chart remained shrouded in mystery. Questions about these early navigational charts included whether colorants were commensurate with the time period and geographical location, and if different, did that give insight into trade routes, or possible later additions to the charts? For example; spectral data showed the red pigment on both the 1320 portolan chart and the 1565 Galapagos Islands matched vermillion, an opaque red pigment used since antiquity. The construction of these charts was also of great interest. Spectral imaging with a range of illumination modes revealed the presence of a "hidden circle" often referred to in relation to their construction. This paper will present in-depth analysis of how spectral imaging of the Portolans revealed similarities and differences, new hidden information and shed new light on construction and composition.

  10. The construction of control chart for PM10 functional data

    Science.gov (United States)

    Shaadan, Norshahida; Jemain, Abdul Aziz; Deni, Sayang Mohd

    2014-06-01

    In this paper, a statistical procedure to construct a control chart for monitoring air quality (PM10) using functional data is proposed. A set of daily indices that represent the daily PM10 curves were obtained using Functional Principal Component Analysis (FPCA). By means of an iterative charting procedure, a reference data set that represented a stable PM10 process was obtained. The data were then used as a reference for monitoring future data. The application of the procedure was conducted using seven-year (2004-2010) period of recorded data from the Klang air quality monitoring station located in the Klang Valley region of Peninsular Malaysia. The study showed that the control chart provided a useful visualization tool for monitoring air quality and was capable in detecting abnormality in the process system. As in the case of Klang station, the results showed that with reference to 2004-2008, the air quality (PM10) in 2010 was better than that in 2009.

  11. Varicose vein stripping

    Science.gov (United States)

    ... stripping; Venous reflux - vein stripping; Venous ulcer - veins Patient Instructions Surgical wound care - open Varicose veins - what to ask your doctor Images Circulatory system References American Family Physician. Management of varicose veins. www.aafp.org/afp/2008/ ...

  12. Fractional smith chart theory

    KAUST Repository

    Shamim, Atif

    2011-03-01

    For the first time, a generalized Smith chart is introduced here to represent fractional order circuit elements. It is shown that the standard Smith chart is a special case of the generalized fractional order Smith chart. With illustrations drawn for both the conventional integer based lumped elements and the fractional elements, a graphical technique supported by the analytical method is presented to plot impedances on the fractional Smith chart. The concept is then applied towards impedance matching networks, where the fractional approach proves to be much more versatile and results in a single element matching network for a complex load as compared to the two elements in the conventional approach. © 2010 IEEE.

  13. Testbeam evaluation of silicon strip modules for ATLAS Phase - II Strip Tracker Upgrade

    CERN Document Server

    Blue, Andrew; The ATLAS collaboration; Ai, Xiaocong; Allport, Phillip; Arling, Jan-Hendrik; Atkin, Ryan Justin; Bruni, Lucrezia Stella; Carli, Ina; Casse, Gianluigi; Chen, Liejian; Chisholm, Andrew; Cormier, Kyle James Read; Cunningham, William Reilly; Dervan, Paul; Diez Cornell, Sergio; Dolezal, Zdenek; Dopke, Jens; Dreyer, Etienne; Dreyling-Eschweiler, Jan Linus Roderik; Escobar, Carlos; Fabiani, Veronica; Fadeyev, Vitaliy; Fernandez Tejero, Javier; Fleta Corral, Maria Celeste; Gallop, Bruce; Garcia-Argos, Carlos; Greenall, Ashley; Gregor, Ingrid-Maria; Greig, Graham George; Guescini, Francesco; Hara, Kazuhiko; Hauser, Marc Manuel; Huang, Yanping; Hunter, Robert Francis Holub; Keller, John; Klein, Christoph; Kodys, Peter; Koffas, Thomas; Kotek, Zdenek; Kroll, Jiri; Kuehn, Susanne; Lee, Steven Juhyung; Liu, Yi; Lohwasser, Kristin; Meszarosova, Lucia; Mikestikova, Marcela; Mi\\~nano Moya, Mercedes; Mori, Riccardo; Moser, Brian; Nikolopoulos, Konstantinos; Peschke, Richard; Pezzullo, Giuseppe; Phillips, Peter William; Poley, Anne-luise; Queitsch-Maitland, Michaela; Ravotti, Federico; Rodriguez Rodriguez, Daniel

    2018-01-01

    The planned HL-LHC (High Luminosity LHC) is being designed to maximise the physics potential of the LHC with 10 years of operation at instantaneous luminosities of \\mbox{$7.5\\times10^{34}\\;\\mathrm{cm}^{-2}\\mathrm{s}^{-1}$}. A consequence of this increased luminosity is the expected radiation damage requiring the tracking detectors to withstand hadron equivalences to over $1x10^{15}$ 1 MeV neutron equivalent per $cm^{2}$ in the ATLAS Strips system. The silicon strip tracker exploits the concept of modularity. Fast readout electronics, deploying 130nm CMOS front-end electronics are glued on top of a silicon sensor to make a module. The radiation hard n-in-p micro-strip sensors used have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics. A series of tests were performed at the DESY-II test beam facility to investigate the detailed performance of a strip module with both 2.5cm and 5cm length strips before irradiation. The DURANTA telescope was used to obtain a pointing...

  14. Using an electronic medical record to improve communication within a prenatal care network.

    Science.gov (United States)

    Bernstein, Peter S; Farinelli, Christine; Merkatz, Irwin R

    2005-03-01

    In 2002, the Institute of Medicine called for the introduction of information technologies in health care settings to improve quality of care. We conducted a review of hospital charts of women who delivered before and after the implementation of an intranet-based computerized prenatal record in an inner-city practice. Our objective was to assess whether the use of this record improved communication among the outpatient office, the ultrasonography unit, and the labor floor. The charts of patients who delivered in August 2002 and August 2003 and received their prenatal care at the Comprehensive Family Care Center at Montefiore Medical Center were analyzed. Data collected included the presence of a copy of the prenatal record in the hospital chart, the date of the last documented prenatal visit, and documentation of any prenatal ultrasonograms performed. Forty-three charts in each group were available for review. The prenatal chart was absent in 16% of the charts of patients from August 2002 compared with only 2% in August 2003 charts (P intranet-based prenatal chart significantly improves communication among providers.

  15. INIS: Terminology charts

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1970-08-01

    This document is one in a series of publications known as the INIS Reference Series. It is to be used in conjunction with the INIS indexing manual and the INIS thesaurus for the preparation of input to the INIS database. The thesaurus and terminology charts in their first edition (Rev.0) were produced as the result of an agreement between the International Atomic Energy Agency (IAEA) and the European Atomic Energy Community (Euratom). Except for minor changes the terminology and the interrelationships between terms are those of the December 1969 edition of the Euratom Thesaurus. The purpose of the terminology harts is to display the descriptors of the thesaurus in the context of their hierarchical and other semantic relationships. Hierarchically related terms are grouped in clusters, each representing one of the principal concepts of a subject field. The descriptors are grouped around or under the broadest term of the clusters which is printed in upper case. The hierarchical relationships within the clusters are shown by the arrangement of the terms in smaller boxes within the larger boxes circumscribing the clusters. The clusters are connected by lines of various thickness, representing the other (mostly non-hierarchical) relationships. These connections are the equivalent to 'see also' and 'related term' cross-references. The thickness of the lines represents the strength of the semantic relations, or, in the practice of a retrieval system the probability that one term replacing a connected term in a query, will still yield pertinent references. The figures accompanying the descriptors represent their frequency of assignment to the first 987,000 documents stored in the Euratom system (May 1970). They are presented in order to show the relative importance of the descriptors within the subject field. The asterisks (*) accompanying descriptors in the charts refer to descriptors, for which a scope note can be found in the INIS: Thesaurus at the time the charts went

  16. INIS: Terminology charts

    International Nuclear Information System (INIS)

    1970-08-01

    This document is one in a series of publications known as the INIS Reference Series. It is to be used in conjunction with the INIS indexing manual and the INIS thesaurus for the preparation of input to the INIS database. The thesaurus and terminology charts in their first edition (Rev.0) were produced as the result of an agreement between the International Atomic Energy Agency (IAEA) and the European Atomic Energy Community (Euratom). Except for minor changes the terminology and the interrelationships between terms are those of the December 1969 edition of the Euratom Thesaurus. The purpose of the terminology harts is to display the descriptors of the thesaurus in the context of their hierarchical and other semantic relationships. Hierarchically related terms are grouped in clusters, each representing one of the principal concepts of a subject field. The descriptors are grouped around or under the broadest term of the clusters which is printed in upper case. The hierarchical relationships within the clusters are shown by the arrangement of the terms in smaller boxes within the larger boxes circumscribing the clusters. The clusters are connected by lines of various thickness, representing the other (mostly non-hierarchical) relationships. These connections are the equivalent to 'see also' and 'related term' cross-references. The thickness of the lines represents the strength of the semantic relations, or, in the practice of a retrieval system the probability that one term replacing a connected term in a query, will still yield pertinent references. The figures accompanying the descriptors represent their frequency of assignment to the first 987,000 documents stored in the Euratom system (May 1970). They are presented in order to show the relative importance of the descriptors within the subject field. The asterisks (*) accompanying descriptors in the charts refer to descriptors, for which a scope note can be found in the INIS: Thesaurus at the time the charts went

  17. WWW chart of the nuclides

    International Nuclear Information System (INIS)

    Huang Xiaolong; Zhou Chunmei; Zhuang Youxiang; Zhao Zhixiang; Golashvili, T.V.; Chechev, V.P.

    2000-01-01

    WWW chart of the nuclides was established on the basis of the latest evaluations of nuclear structure and decay data. By viewing WWW chart of the nuclides, one can retrieve the fundamental data of nuclide such as atomic mass, abundance, spin and parity; the decay mode, branching ratio, half-life and Q-value of radioactive nuclide, energy and intensity of strong γ-ray, etc. The URL (Uniform Resource Locator) of WWW chart of the nuclides is: http://myhome.py.gd.cn/chart/index,asp

  18. Anatomy Comic Strips

    Science.gov (United States)

    Park, Jin Seo; Kim, Dae Hyun; Chung, Min Suk

    2011-01-01

    Comics are powerful visual messages that convey immediate visceral meaning in ways that conventional texts often cannot. This article's authors created comic strips to teach anatomy more interestingly and effectively. Four-frame comic strips were conceptualized from a set of anatomy-related humorous stories gathered from the authors' collective…

  19. Multichannel waveform display system

    International Nuclear Information System (INIS)

    Kolvankar, V.G.

    1989-01-01

    For any multichannel data acquisition system, a multichannel paper chart recorder undoubtedly forms an essential part of the system. When deployed on-line, it instantaneously provides, for visual inspection, hard copies of the signal waveforms on common time base at any desired sensitivity and time resolution. Within the country, only a small range of these strip chart recorder s is available, and under stringent specifications imported recorders are often procured. The cost of such recorders may range from 1 to 5 lakhs of rupees in foreign exchange. A system to provide on the oscilloscope a steady display of multichannel waveforms, refreshed from the digital data stored in the memory is developed. The merits and demerits of the display system are compared with that built around a conventional paper chart recorder. Various illustrations of multichannel seismic event data acquired at Gauribidanur seismic array station are also presented. (author). 2 figs

  20. Multivariate Statistical Process Control Charts: An Overview

    OpenAIRE

    Bersimis, Sotiris; Psarakis, Stelios; Panaretos, John

    2006-01-01

    In this paper we discuss the basic procedures for the implementation of multivariate statistical process control via control charting. Furthermore, we review multivariate extensions for all kinds of univariate control charts, such as multivariate Shewhart-type control charts, multivariate CUSUM control charts and multivariate EWMA control charts. In addition, we review unique procedures for the construction of multivariate control charts, based on multivariate statistical techniques such as p...

  1. Science Comic Strips

    Science.gov (United States)

    Kim, Dae Hyun; Jang, Hae Gwon; Shin, Dong Sun; Kim, Sun-Ja; Yoo, Chang Young; Chung, Min Suk

    2012-01-01

    Science comic strips entitled Dr. Scifun were planned to promote science jobs and studies among professionals (scientists, graduate and undergraduate students) and children. To this end, the authors collected intriguing science stories as the basis of scenarios, and drew four-cut comic strips, first on paper and subsequently as computer files.…

  2. The Hill Chart Calculation for Pelton Runner Models using the HydroHillChart - Pelton Module Software

    Directory of Open Access Journals (Sweden)

    Adelina Bostan

    2015-07-01

    Full Text Available The Pelton turbines industrial design is based on the hill chart characteristics obtained by measuring the models. Primary data measurements used to obtain the hill chart can be processed graphically, by hand or by using graphic programs respectively CAD programs; the HydroHillChart - Pelton module software is a specialized tool in achieving the hill chart, using interpolation cubic spline functions. Thereby, based on measurements of several models of Pelton turbines, a computerized library, used to design industrial Pelton turbines can be created. The paper presents the universal characteristics calculated by using the HydroHillChart - Pelton module software for a series of Pelton runners.

  3. The Strip Module

    DEFF Research Database (Denmark)

    Pedersen, Tommy

    1996-01-01

    When the behaviour of a ship in waves is to be predicted it is convenient to have a tool which includes different approaches to the problem.The aim of this project is to develop such a tool named the strip theory module. The strip theory module will consist of submodules dependent on the I...

  4. Nuclear reactor spring strip grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Flora, B.S.

    1978-01-01

    A bimetallic grid spacer is described comprising a grid structure of zircaloy formed by intersecting striplike members which define fuel element openings for receiving fuel elements and spring strips made of Inconel positioned within the grid structure for cooperating with the fuel elements to maintain them in their desired position. A plurality of these spring strips extend longitudinally between sides of the grid structure, being locked in position by the grid retaining strips. The fuel rods, which are disposed in the fuel openings formed in the grid structure, are positioned by means of the springs associated with the spring strips and a plurality of dimples which extend from the zircaloy grid structure into the openings. In one embodiment the strips are disposed in a plurality of arrays with those spring strip arrays situated in opposing diagonal quadrants of the grid structure extending in the same direction and adjacent spring strip arrays in each half of the spacer extending in relatively perpendicular directions. Other variations of the spring strip arrangements for a particular fuel design are disclosed herein

  5. SMART AERONAUTICAL CHART MANAGEMENT SYSTEM DESIGN

    Directory of Open Access Journals (Sweden)

    M. E. Pakdil

    2015-10-01

    Full Text Available Civil aviation is developing rapidly, and the number of domestic and international operations is increasing exponentially every year than the previous one. Airline companies with increased air traffic and the number of passengers increase the demand of new aircrafts. An aircraft needs not only fuel but also pilot and aeronautical information (charts, digital navigation information, flight plan, and etc. to perform flight operation. One of the most important components in aeronautical information is the terminal chart. Authorized institution in every state is responsible to publish their terminal charts for certain periods. Although these charts are produced in accordance with ICAO’s Annex 4 and Annex 15, cartographic representation and page layout differs in each state’s publication. This situation makes difficult to read them by pilots. In this paper, standard instrument departure (SID charts are analysed to produce by use of cutting-edge and competitive technologies instead of classical computer-aided drawing and vector based graphic applications that are currently used by main chart producers. The goal is to design efficient and commercial chart management system that is able to produce aeronautical charts with same cartographic representation for all states.

  6. Noise analysis due to strip resistance in the ATLAS SCT silicon strip module

    International Nuclear Information System (INIS)

    Kipnis, I.

    1996-08-01

    The module is made out of four 6 cm x 6 cm single sided Si microstrip detectors. Two detectors are butt glued to form a 12 cm long mechanical unit and strips of the two detectors are electrically connected to form 12 cm long strips. The butt gluing is followed by a back to back attachment. The module in this note is the Rφ module where the electronics is oriented parallel to the strip direction and bonded directly to the strips. This module concept provides the maximum signal-to-noise ratio, particularly when the front-end electronics is placed near the middle rather than at the end. From the noise analysis, it is concluded that the worst-case ΔENC (far-end injection) between end- and center-tapped modules will be 120 to 210 el. rms (9 to 15%) for a non-irradiated detector and 75 to 130 el. rms (5 to 9%) for an irradiated detector, for a metal strip resistance of 10 to 20 Ω/cm

  7. Strip casting apparatus and method

    Science.gov (United States)

    Williams, R.S.; Baker, D.F.

    1988-09-20

    Strip casting apparatus including a molten-metal-holding container and a nozzle to deposit molten metal onto a moving chill drum to directly cast continuous metallic strip. The nozzle body includes a slot bounded between a back and a front lip. The slot width exceeds about 20 times the gap distance between the nozzle and the chill drum surface. Preferably, the slot width exceeds 0.5 inch. This method of strip casting minimizes pressure drop, insuring better metal-to-chill-drum contact which promotes heat transfer and results in a better quality metallic strip. 6 figs.

  8. The Whipple Strip Sky Survey

    Science.gov (United States)

    Kertzman, M. P.

    As part of the normal operation of the Whipple 10m Gamma Ray telescope, ten minute drift scan “zenith” runs are made each night of observation for use as calibration. Most of the events recorded during a zenith run are due to the background of cosmic ray showers. However, it would be possible for a hitherto unknown source of gamma rays to drift through the field. This paper reports the results of a search for serendipitous high energy gamma ray sources in the Whipple 10m nightly calibration zenith data. From 2000-2004 nightly calibration runs were taken at an elevation of 89 º. A 2- D analysis of these drift scan runs produces a strip of width ~ 3.5º in declination and spanning the full range of right ascension. In the 2004-05 observing season the calibration runs were taken at elevations of 86° and 83°. Beginning in the 2005-06 season, the nightly calibration runs were taken at an elevation of 80º. Collectively, these drift scans cover a strip approximately 12.5º wide in declination, centered at declination 37.18º, and spanning the full range of RA. The analysis procedures developed for drift scan data, the sensitivity of the method, and the results will be presented.

  9. Control of control charts

    NARCIS (Netherlands)

    Sri Nurdiati, S.N.

    2005-01-01

    Although the Shewhart chart is widely used in practice because of its simplicity, applying this control chart to monitor the mean of a process may lead to two types of problems. The first concerns the typically unknown parameters involved in the distribution, while the second concerns the validity

  10. Providing a complete online multimedia patient record.

    Science.gov (United States)

    Dayhoff, R. E.; Kuzmak, P. M.; Kirin, G.; Frank, S.

    1999-01-01

    Seamless integration of all types of patient data is a critical feature for clinical workstation software. The Dept. of Veterans Affairs has developed a multimedia online patient record that includes traditional medical chart information as well as a wide variety of medical images from specialties such as cardiology, pulmonary and gastrointestinal medicine, pathology, radiology, hematology, and nuclear medicine. This online patient record can present data in ways not possible with a paper chart or other physical media. Obtaining a critical mass of information online is essential to achieve the maximum benefits from an integrated patient record system. Images Figure 1 Figure 2 PMID:10566357

  11. International chart of the nuclides. 2001

    International Nuclear Information System (INIS)

    Golashvili, T.V.; Kupriyanov, V.M.; Lbov, A.A.

    2002-01-01

    The International Chart of Nuclides - 2001 has been developed taking into account the data obtained in 1998-2001. Unlike widespread nuclide charts the present Chart of Nuclides contains EVALUATED values of the main characteristics. These values are supplied with the standard deviations. (author)

  12. Shewhart control charts in new perspective

    NARCIS (Netherlands)

    Albers, Willem/Wim; Kallenberg, W.C.M.

    2007-01-01

    The effects of estimating parameters and the violation of the assumption of normality when dealing with control charts are discussed. Corrections for estimating errors and extensions of the normal control chart to parametric and nonparametric charts are investigated. The underlying theory is

  13. NNDC Chart of Nuclides

    International Nuclear Information System (INIS)

    Sonzogni, A.

    2008-01-01

    The National Nuclear Data Center has recently developed an interactive chart of nuclides, http://www.nndc.bnl.gov/chart/, that provides nuclear structure and decay data. Since its implementation, it has proven to be one of the most popular web products. The information presented is derived from the ENSDF and Nuclear Wallet Card databases. Experimentally known nuclides are represented by a cell in chart with the number of neutrons on the horizontal axis and the number of protons on the vertical axis. The color of the cell is used to indicate the ground state half-life or the ground state predominant decay mode. (author)

  14. Flowcharting with D-charts

    Science.gov (United States)

    Meyer, D.

    1985-01-01

    A D-Chart is a style of flowchart using control symbols highly appropriate to modern structured programming languages. The intent of a D-Chart is to provide a clear and concise one-for-one mapping of control symbols to high-level language constructs for purposes of design and documentation. The notation lends itself to both high-level and code-level algorithmic description. The various issues that may arise when representing, in D-Chart style, algorithms expressed in the more popular high-level languages are addressed. In particular, the peculiarities of mapping control constructs for Ada, PASCAL, FORTRAN 77, C, PL/I, Jovial J73, HAL/S, and Algol are discussed.

  15. Paediatric Northern Score centile charts for the chest radiograph in cystic fibrosis

    International Nuclear Information System (INIS)

    McCormick, J.; Conway, S.P.; Mehta, A.

    2007-01-01

    Aim: To create the first national centile charts for the chest radiograph Northern Score using the UK Cystic Fibrosis (CF) Database (UKCFD). Materials and methods: All active patients for 2002 from the UKCFD were analysed in 1-year cohorts from 0 to 18 years. Northern Score results from the annual review forms were used to construct centile lines for the 5th, 25th, 50th, 75th, 95th centiles. Results: There were 1806 patients with recorded Northern Score data for 2002 (927 male patients, male:female ratio 1.05). The centile chart demonstrates a quasi-linear rise throughout childhood. A Northern Score in excess of age in years equates to >95th centile in school-aged CF patients. Conclusion: This centile chart provides a disease-specific reference range for monitoring individual patients or for evaluating therapeutic change using the dominant chest radiograph scoring system in the UK. Patients, parents and clinicians may find these useful during the annual review process

  16. de Sitter relativity in static charts

    Energy Technology Data Exchange (ETDEWEB)

    Cotaescu, Ion I. [West University of Timisoara, Timisoara (Romania)

    2018-02-15

    The relative geodesic motion in static (and spherically symmetric) local charts on the (1 + 3)-dimensional de Sitter spacetimes is studied in terms of conserved quantities. The Lorentzian isometries are derived, relating the coordinates of the local chart of a fixed observer with the coordinates of a mobile chart considered as the rest frame of a massive particle freely moving on a timelike geodesic. The time dilation and Lorentz contraction are discussed pointing out some notable features of the de Sitter relativity in static charts. (orig.)

  17. The Honeycomb Strip Chamber

    International Nuclear Information System (INIS)

    Graaf, Harry van der; Buskens, Joop; Rewiersma, Paul; Koenig, Adriaan; Wijnen, Thei

    1991-06-01

    The Honeycomb Strip Chamber (HSC) is a new position sensitive detector. It consists of a stack of folded foils, forming a rigid honeycomb structure. In the centre of each hexagonal cell a wire is strung. Conducting strips on the foils, perpendicular to the wires, pick up the induced avalanche charge. Test results of a prototype show that processing the signals form three adjacent strips nearest to the track gives a spatial resolution better than 64 μm for perpendicular incident tracks. The chamber performance is only slightly affected by a magnetic field. (author). 25 refs.; 21 figs

  18. Software tool for physics chart checks.

    Science.gov (United States)

    Li, H Harold; Wu, Yu; Yang, Deshan; Mutic, Sasa

    2014-01-01

    Physics chart check has long been a central quality assurance (QC) measure in radiation oncology. The purpose of this work is to describe a software tool that aims to accomplish simplification, standardization, automation, and forced functions in the process. Nationally recognized guidelines, including American College of Radiology and American Society for Radiation Oncology guidelines and technical standards, and the American Association of Physicists in Medicine Task Group reports were identified, studied, and summarized. Meanwhile, the reported events related to physics chart check service were analyzed using an event reporting and learning system. A number of shortfalls in the chart check process were identified. To address these problems, a software tool was designed and developed under Microsoft. Net in C# to hardwire as many components as possible at each stage of the process. The software consists of the following 4 independent modules: (1) chart check management; (2) pretreatment and during treatment chart check assistant; (3) posttreatment chart check assistant; and (4) quarterly peer-review management. The users were a large group of physicists in the author's radiation oncology clinic. During over 1 year of use the tool has proven very helpful in chart checking management, communication, documentation, and maintaining consistency. The software tool presented in this work aims to assist physicists at each stage of the physics chart check process. The software tool is potentially useful for any radiation oncology clinics that are either in the process of pursuing or maintaining the American College of Radiology accreditation.

  19. Selective chemical stripping

    Science.gov (United States)

    Malavallon, Olivier

    1995-04-01

    At the end of the 80's, some of the large European airlines expressed a wish for paint systems with improved strippability on their aircraft, allowing the possibility to strip down to the primer without altering it, using 'mild' chemical strippers based on methylene chloride. These improvements were initially intended to reduce costs and stripping cycle times while facilitating rapid repainting, and this without the need to change the conventionally used industrial facilities. The level of in-service performance of these paint systems was to be the same as the previous ones. Requirements related to hygiene safety and the environment were added to these initial requirements. To meet customers' expectations, Aerospatiale, within the Airbus Industry GIE, formed a work group. This group was given the task of specifying, following up the elaboration and qualifying the paint systems allowing requirements to be met, in relation with the paint suppliers and the airlines. The analysis made in this report showed the interest of transferring as far upstream as possible (to paint conception level) most of the technical constraints related to stripping. Thus, the concept retained for the paint system, allowing selective chemical stripping, is a 3-coat system with characteristics as near as possible to the previously used paints.

  20. Charge collection in silicon strip detectors

    International Nuclear Information System (INIS)

    Kraner, H.W.; Beuttenmuller, R.; Ludlam, T.; Hanson, A.L.; Jones, K.W.; Radeka, V.; Heijne, E.H.M.

    1982-11-01

    The use of position sensitive silicon detectors as very high resolution tracking devices in high energy physics experiments has been a subject of intense development over the past few years. Typical applications call for the detection of minimum ionizing particles with position measurement accuracy of 10 μm in each detector plane. The most straightforward detector geometry is that in which one of the collecting electrodes is subdivided into closely spaced strips, giving a high degree of segmentation in one coordinate. Each strip may be read out as a separate detection element, or, alternatively, resistive and/or capacitive coupling between adjacent strips may be exploited to interpolate the position via charge division measrurements. With readout techniques that couple several strips, the numer of readout channels can, in principle, be reduced by large factors without sacrificing the intrinsic position accuracy. The testing of individual strip properties and charge division between strips has been carried out with minimum ionizing particles or beams for the most part except in one case which used alphs particless scans. This paper describes the use of a highly collimated MeV proton beam for studies of the position sensing properties of representative one dimensional strip detectors

  1. NOAA Raster Navigational Charts (RNC)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA, National Ocean Service, Office of Coast Survey, Marine Chart Division is responsible to build and maintain a suite of more than 1000 nautical charts that are...

  2. Parallel superconducting strip-line detectors: reset behaviour in the single-strip switch regime

    International Nuclear Information System (INIS)

    Casaburi, A; Heath, R M; Tanner, M G; Hadfield, R H; Cristiano, R; Ejrnaes, M; Nappi, C

    2014-01-01

    Superconducting strip-line detectors (SSLDs) are an important emerging technology for the detection of single molecules in time-of-flight mass spectrometry (TOF-MS). We present an experimental investigation of a SSLD laid out in a parallel configuration, designed to address selected single strip-lines operating in the single-strip switch regime. Fast laser pulses were tightly focused onto the device, allowing controllable nucleation of a resistive region at a specific location and study of the subsequent device response dynamics. We observed that in this regime, although the strip-line returns to the superconducting state after triggering, no effective recovery of the bias current occurs, in qualitative agreement with a phenomenological circuit simulation that we performed. Moreover, from theoretical considerations and by looking at the experimental pulse amplitude distribution histogram, we have the first confirmation of the fact that the phenomenological London model governs the current redistribution in these large area devices also after detection events. (paper)

  3. Bearing Capacity of Strip Footings near Slopes Using Lower Bound Limit Analysis

    Directory of Open Access Journals (Sweden)

    Javad Mofidi rouchi

    2014-06-01

    Full Text Available Stability of foundations near slopes is one of the important and complicated problems in geotechnical engineering, which has been investigated by various methods such as limit equilibrium, limit analysis, slip-line, finite element and discrete element. The complexity of this problem is resulted from the combination of two probable failures: foundation failure and overall slope failure. The current paper describes a lower bound solution for estimation of bearing capacity of strip footings near slopes. The solution is based on the finite element formulation and linear programming technique, which lead to a collapse load throughout a statically admissible stress field. Three-nodded triangular stress elements are used for meshing the domain of the problem, and stress discontinuities occur at common edges of adjacent elements. The Mohr-Coulomb yield function and an associated flow rule are adopted for the soil behavior. In this paper, the average limit pressure of strip footings, which are adjacent to slopes, is considered as a function of dimensionless parameters affecting the stability of the footing-on-slope system. These parameters, particularly the friction angle of the soil, are investigated separately and relevant charts are presented consequently. The results are compared to some other solutions that are available in the literature in order to verify the suitability of the methodology used in this research.

  4. Construction and validation of a Tamil logMAR chart.

    Science.gov (United States)

    Varadharajan, Srinivasa; Srinivasan, Krithica; Kumaresan, Brindha

    2009-09-01

    To design, construct and validate a new Tamil logMAR visual acuity chart based on current recommendations. Ten Tamil letters of equal legibility were identified experimentally and were used in the chart. Two charts, one internally illuminated and one externally illuminated, were constructed for testing at 4 m distance. The repeatability of the two charts was tested. For validation, the two charts were compared with a standard English logMAR chart (ETDRS). When compared to the ETDRS chart, a difference of 0.06 +/- 0.07 and 0.07 +/- 0.07 logMAR was found for the internally and externally illuminated charts respectively. Limits of agreement between the internally illuminated Tamil logMAR chart and ETDRS chart were found to be (-0.08, 0.19), and (-0.07, 0.20) for the externally illuminated chart. The test - retest results showed a difference of 0.02 +/- 0.04 and 0.02 +/- 0.06 logMAR for the internally and externally illuminated charts respectively. Limits of agreement for repeated measurements for the internally illuminated Tamil logMAR chart were found to be (-0.06, 0.10), and (-0.10, 0.14) for the externally illuminated chart. The newly constructed Tamil logMAR charts have good repeatability. The difference in visual acuity scores between the newly constructed Tamil logMAR chart and the standard English logMAR chart was within acceptable limits. This new chart can be used for measuring visual acuity in the literate Tamil population.

  5. [A blood glucose slide chart for improving diabetes patient education].

    Science.gov (United States)

    Potteau, Marie-Hélène

    2015-03-01

    A blood glucose slide chart has been developed in order to help patients with type 2 diabetes who do not speak French or who have comprehension difficulties. Combined with pictograms to help patients visualise the action they need to take depending on the recorded glucose level, it constitutes a therapeutic education tool which can be useful on a day-to-day basis both for patients as well as caregivers.

  6. Chart Series

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Centers for Medicare and Medicaid Services (CMS) offers several different Chart Series with data on beneficiary health status, spending, operations, and quality...

  7. A near-vision chart for children aged 3-5 years old:new designs and clinical applications

    Directory of Open Access Journals (Sweden)

    Yang-Qing Huang

    2014-06-01

    Full Text Available AIM:To introduce a new near-vision chart for children aged 3-5 years old and its clinical applications.METHODS:The new near-vision chart which combined the Bailey-Lovie layout with a newly devised set of symmetry symbols was designed based on Weber-Fechner law. It consists of 15 rows of symmetry symbols, corresponding to a visual acuity range from 1.3 to 0.1 logMAR. The optotypes were red against a white background and were specially shaped four basic geometric symbols:circle, square, triangle,and cross, which matched the preschool children''s cognitive level. A regular geometric progression of the optotype sizes and distribution was employed to arrange in 15 lines. The progression rate of the optotype size between two lines was 1.2589 and two smaller groups of optotypes ranging from 0.7 to -0.1 logMAR were included for repetitive testing. A near visual acuity was recorded in logMAR or decimal, and the testing distance was 25 cm.RESULTS:This new near-vision chart with pediatric acuity test optotypes which consists of 4 different symbols (triangle, square, cross, and circle met the national and international eye chart design guidelines. When performing the near visual acuity assessment in preschoolers (3-5 years old. It overcame an inability to recognize the letters of the alphabet and difficulties in designating the direction of black abstract symbols such as the tumbling ''E'' or Landolt ''C'', which the subjects were prone to lose interest in. Near vision may be recorded in different notations:decimal acuity and logMAR. These two notations can be easily converted each other in the new near-vision chart. The measurements of this new chart not only showed a significant correlation and a good consistency with the Chinese national standard logarithmic near-vision chart (r=0.932, P<0.01, but also indicated good test-retest reliability (89% of retest scores were within 0.1 logMAR units of the initial test score and a high response rate

  8. Optimizing the Stripping Procedure for LHCb

    CERN Document Server

    Richardson, Rachel

    2017-01-01

    The LHCb experiment faces a major challenge from the large amounts of data received while the LHC is running. The ability to sort this information in a useful manner is important for working groups to perform physics analyses. Both hardware and software triggers are used to decrease the data rate and then the stripping process is used to sort the data into streams and further into stripping lines. This project studies the hundreds of stripping lines to look for overlaps between them in order to make the stripping process more efficient.

  9. Using Comic Strips in Language Classes

    Science.gov (United States)

    Csabay, Noémi

    2006-01-01

    The author believes that using comic strips in language-learning classes has three main benefits. First, comic strips motivate younger learners. Second, they provide a context and logically connected sentences to help language learning. Third, their visual information is helpful for comprehension. The author argues that comic strips can be used in…

  10. Falls documentation in nursing homes: agreement between the minimum data set and chart abstractions of medical and nursing documentation.

    Science.gov (United States)

    Hill-Westmoreland, Elizabeth E; Gruber-Baldini, Ann L

    2005-02-01

    To assess the agreement between falls as recorded in the Minimum Data Set (MDS) and fall events abstracted from chart documentation of elderly nursing home (NH) residents. Secondary analysis of data from a longitudinal panel study. Fifty-six randomly selected NHs in Maryland stratified by facility size and geographic region. Four hundred sixty-two NH residents, aged 65 and older, in NHs for 1 year. Falls were abstracted from resident charts and compared with MDS fall variables. Fall events data obtained from other sources of chart documentation were matched for the corresponding periods of 30 and 180 days before the 1-year MDS assessment date. For a 30-day period, concordance between the MDS and chart abstractions of falls occurred in 65% of cases, with a kappa coefficient of 0.29 (Pfalls the MDS missed indicated that these residents had significantly more activity of daily living impairment and significantly less unsteady gait and cane/walker use. The MDS underreported falls. Nurses completing MDS assessments must carefully review residents' medical records for falls documentation. Future studies should use caution when employing MDS data as the only indicator of falls.

  11. Test-beam evaluation of heavily irradiated silicon strip modules for ATLAS Phase-II Strip Tracker Upgrade

    CERN Document Server

    Blue, Andrew; The ATLAS collaboration

    2018-01-01

    The planned HL-LHC (High Luminosity LHC) is being designed to maximise the physics potential of the LHC with 10 years of operation at instantaneous luminosities of 7.5x1034cm−2s−1. A consequence of this increased luminosity is the expected radiation damage requiring the tracking detectors to withstand hadron equivalences to over 1x1015 1 MeV neutron equivalent per cm2 in the ATLAS Strips system. The silicon strip tracker exploits the concept of modularity. Fast readout electronics, deploying 130nm CMOS front-end electronics are glued on top of a silicon sensor to make a module. The radiation hard n-in-p micro-strip sensors used have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics. A series of tests were performed at the DESY-II and CERN SPS test beam facilities to investigate the detailed performance of a strip module with both 2.5cm and 5cm length strips before and after irradiation with 8x1014neqcm−2 protons and a total ionising dose of 37.2MRad. The DURA...

  12. Pavement Stripping in Saudi Arabia: Prediction and Prevention

    Directory of Open Access Journals (Sweden)

    H.I. Al-Abdul Wahhab

    2004-12-01

    Full Text Available Pavement weathering or stripping is a major distress in highway networks in arid regions. Using the Saudi Arabian road network as a case study area, seventeen road test sections were selected, out of which eight were stripped and nine were non-stripped. Aggregates from quarries used to build these sections were also collected and subjected to detailed physical and chemical tests to evaluate the ability of these tests to distinguish between stripped and non-stripped sections. The modified Lottman test was used to distinguish between compacted mixes. In addition, the Swedish Rolling Bottle test, was also found to be effective in being able to distinguish between different asphalt-aggregates for stripping potential. Eleven anti-stripping liquid additives, lime and cement, in addition to two polymers, were evaluated for their ability to reduce/eliminate stripping potential of stripping-prone aggregates. It was found that EE-2 Polymer, Portland cement, and their combination were effective with all aggregate sources.

  13. Subsurface fracture surveys using a borehole television camera and an acoustic televiewer

    International Nuclear Information System (INIS)

    Lau, J.S.O.; Auger, L.F.

    1987-01-01

    Borehole television survey and acoustic televiewer logging provide rapid, cost-effective, and accurate methods of surveying fractures and their characteristics within boreholes varying in diameter from 7.6 to 15.3 cm. In the television survey, a camera probe is used to inspect the borehole walls. Measurements of location, orientation, infilling width, and aperture of fractures are made on the television screen and recorded on computer data record sheets. All observations are recorded on video cassette tapes. With the acoustic televiewer, oriented images of fractures in the borehole walls are recorded on a strip-chart log and also on video cassette tapes. The images are displayed as if the walls were split vertically along magnetic north and spread out horizontally. Measurements of fracture characteristics are made on the strip-chart log, using a digitizing table and a microcomputer, and the data recorded on floppy diskettes. In both surveys, an inclined fracture is displayed as a sinusoidal curve, from which the apparent orientation of the fracture can be measured. Once the borehole orientation is known, the true orientation of the fracture can be computed from its apparent orientation. Computer analysis of the fracture data, provides a rapid assessment of fracture occurrence, fracture aperture, and statisically significant concentrations of fracture orientations

  14. Radar Chart

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Radar Chart collection is an archived product of summarized radar data. The geographic coverage is the 48 contiguous states of the United States. These hourly...

  15. Collective Memory and Nostalgia in The Dutch Radio2 Top2000 Chart 1999-2013

    NARCIS (Netherlands)

    Sterken, Elmer

    The paper analyses the impact of age on the ranking of recorded popular songs in the Dutch Radio2 Top2000 chart in the years 1999-2013. We measure the competition between the loss of collective memory and nostalgia with respect to popular songs.

  16. CMS Silicon Strip Tracker Performance

    CERN Document Server

    Agram, Jean-Laurent

    2012-01-01

    The CMS Silicon Strip Tracker (SST), consisting of 9.6 million readout channels from 15148 modules and covering an area of 198 square meters, needs to be precisely calibrated in order to correctly reconstruct the events recorded. Calibration constants are derived from different workflows, from promptly reconstructed events with particles as well as from commissioning events gathered just before the acquisition of physics runs. The performance of the SST has been carefully studied since the beginning of data taking: the noise of the detector, data integrity, signal-over-noise ratio, hit reconstruction efficiency and resolution have been all investigated with time and for different conditions. In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

  17. Italian cardiovascular mortality charts of the CUORE project: are they comparable with the SCORE charts?

    LENUS (Irish Health Repository)

    Donfrancesco, Chiara

    2010-08-01

    The aim of this study was to build risk charts for the assessment of cardiovascular mortality of the CUORE project, an Italian longitudinal study, and to compare them with the systematic coronary risk evaluation (SCORE) project charts for low risk European countries.

  18. Payroll Records, Business Education: 7734.31.

    Science.gov (United States)

    Mitz, Rochelle

    This brief pamphlet offers a course description to acquaint students with different types of payroll records, and provides experience in the preparation of time cards, the use of charts to figure taxes, making deductions, and completing records to government requirements. Enrollment guidelines; objectives; course content; procedures; learning…

  19. Growth charts of human development

    NARCIS (Netherlands)

    Van Buuren, Stef

    2014-01-01

    This article reviews and compares two types of growth charts for tracking human development over age. Both charts assume the existence of a continuous latent variable, but relate to the observed data in different ways. The D-score diagram summarizes developmental indicators into a single aggregate

  20. The Conjugate Acid-Base Chart.

    Science.gov (United States)

    Treptow, Richard S.

    1986-01-01

    Discusses the difficulties that beginning chemistry students have in understanding acid-base chemistry. Describes the use of conjugate acid-base charts in helping students visualize the conjugate relationship. Addresses chart construction, metal ions, buffers and pH titrations, and the organic functional groups and nonaqueous solvents. (TW)

  1. Correlation between skin color evaluation by skin color scale chart and narrowband reflectance spectrophotometer.

    Science.gov (United States)

    Treesirichod, Arucha; Chansakulporn, Somboon; Wattanapan, Pattra

    2014-07-01

    Various methods are available for the evaluation of skin color. A skin color scale chart is a convenient and inexpensive tool. However, the correlation between a skin color scale chart and objective measurement has not been evaluated. To assess the correlation between skin color evaluation done by a skin color scale chart (Felix von Luschan skin color chart) and a narrowband reflectance spectrophotometer (Mexameter MX18). The participants were evaluated for skin color by using the Felix von Luschan skin color chart (range 1-36) and a narrowband reflectance spectrophotometer (Mexameter MX18) in which the results of the measurements were expressed as Erythema (E) and Melanin (M) indices. Skin color was measured on four different anatomical skin sites from each participant on the medial aspect of the volar and the dorsal regions of both forearms. A total of 208 records from 52 participants were established. The majority of participants (19.2%) were rated with the skin color scale at the number 16 (range 14-33). The mean M plus E, M, and E indices were 498.9 ± 143.9, 230.4 ± 74.4, and 268.5 ± 73.2, respectively. The correlation coefficient between the number on the skin color scale and each index: M plus E, M, and E indices were 0.90, 0.90, and 0.86, respectively, with a statistical significance of P spectrophotometer.

  2. Large strip RPCs for the LEPS2 TOF system

    Energy Technology Data Exchange (ETDEWEB)

    Tomida, N., E-mail: natsuki@scphys.kyoto-u.ac.jp [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Niiyama, M. [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Ohnishi, H. [RIKEN (The Institute of Physical and Chemical Research), Wako, Saitama 351-0198 (Japan); Tran, N. [Research Center for Nuclear Physics (RCNP), Osaka University, Ibaraki, Osaka 567-0047 (Japan); Hsieh, C.-Y.; Chu, M.-L.; Chang, W.-C. [Institute of Physics, Academia Sinica, Nankang, Taipei 11529, Taiwan (China); Chen, J.-Y. [National Synchrotron Radiation Research Center (NSRRC), Hsinchu 30076, Taiwan (China)

    2014-12-01

    High time-resolution resistive plate chambers (RPCs) with large-size readout strips are developed for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. The experimental requirement is a 50-ps time resolution for a strip size larger than 100 cm{sup 2}/channel. We are able to achieve 50-ps time resolutions with 2.5×100 cm{sup 2} strips by directly connecting the amplifiers to strips. With the same time resolution, the number of front-end electronics (FEE) is also reduced by signal addition. - Highlights: • Find a way to achieve a good time resolution with a large strip RPC. • 2.5 cm narrow strips have better resolutions than 5.0 cm ones. • The 0.5 mm narrow strip interval shows flat time resolutions between strips. • FEEs directly connected to strips make the signal reflection at the strip edge small. • A time resolution of 50 ps was achieved with 2.5 cm×100 cm strips.

  3. Air Emissions Sources, Charts and Maps

    Data.gov (United States)

    U.S. Environmental Protection Agency — Air Emissions provides (1) interactive charts supporting national, state, or county charts, (2) county maps of criteria air pollutant emissions for a state, and (3)...

  4. Mechanical behaviour of a creased thin strip

    Directory of Open Access Journals (Sweden)

    J. Liu

    2018-02-01

    Full Text Available In this study the mechanical behaviour of a creased thin strip under opposite-sense bending was investigated. It was found that a simple crease, which led to the increase of the second moment of area, could significantly alter the overall mechanical behaviour of a thin strip, for example the peak moment could be increased by 100 times. The crease was treated as a cylindrical segment of a small radius. Parametric studies demonstrated that the geometry of the strip could strongly influence its flexural behaviour. We showed that the uniform thickness and the radius of the creased segment had the greatest and the least influence on the mechanical behaviour, respectively. We further revealed that material properties could dramatically affect the overall mechanical behaviour of the creased strip by gradually changing the material from being linear elastic to elastic-perfect plastic. After the formation of the fold, the moment of the two ends of the strip differed considerably when the elasto-plastic materials were used, especially for materials with smaller tangent modulus in the plastic range. The deformation patterns of the thin strips from the finite element simulations were verified by physical models made of thin metal strips. The findings from this study provide useful information for designing origami structures for engineering applications using creased thin strips.

  5. Recognition versus Resolution: a Comparison of Visual Acuity Results Using Two Alternative Test Chart Optotype

    Science.gov (United States)

    Pointer, Jonathan S.

    2010-01-01

    Purpose To quantify the difference between recognition (letter) and resolution (Landolt) visual acuity (VA) in a group of normally sighted subjects. Is it reasonable to assume that the two acuity measures are clinically equivalent? Methods A pair of 6 m acuity test charts was produced: one comprised letters and the other Landolt broken rings. Construction of both charts conformed to the logMAR design format. Monocular VA was determined for the dominant eye of 300 screened and normally sighted optometric patients aged 16 to 40, each wearing an optical refractive (spectacle) correction. Results Letter acuity was superior to Landolt acuity (P≤0.0001). The mean paired acuity difference was -0.041 logMAR (standard deviation 0.034): the 95% limits of agreement were ±0.067 logMAR units or ±3.3 chart optotype. Repeatability was high and similar for each chart type (±2.1 and ±2.4 optotype for letter and Landolt, respectively). Gender, test sequence, and laterality of the dominant eye (left or right) were each non-statistically significant variables. Conclusions For normally sighted subjects wearing an optimal refractive correction, a bias was recorded in favour of recognition over resolution acuity: the clinical difference amounted to approximately 40% of one logMAR chart line, with similar high repeatability for either chart optotype. We conclude that the assumption of clinical equivalence between letter and Landolt acuity is reasonable under optimum test conditions.

  6. A new specialized visual acuity chart for amblyopic children aged 3-5 years old:development and its clinical applications

    Directory of Open Access Journals (Sweden)

    Yang-Qing Huang

    2013-12-01

    Full Text Available AIM: To introduce a new specialized visual acuity chart for amblyopic children aged 3-5 years old and its clinical applications.METHODS:The new visual acuity chart and notations were designed based on Weber-Fechner law. The optotypes were red against a white background and were specially shaped four basic geometric symbols:circle, square, triangle,and cross. A regular geometric progression of the optotype sizes and distribution was employed to arrange in 14 lines. The progression rate of the optotype size between two lines was 1.2589 and the testing distance was 3m. Visual acuity score could be recorded as logMAR notation or decimal notation. Age-stratified diagnostic criteria for amblyopia established by consensus statement on diagnosis of amblyopia (2011 among members of the Strabismus and Pediatric Ophthalmology Group, Ophthalmology Society, Chinese Medical Association (SPOGOSCMA were illustrated in the new visual acuity chart.RESULTS: When assessing visual acuity in children aged 3-5 years old, this new visual acuity chart that consists of four symmetrical shapes (triangle, square, cross, and circle overcame an inability to recognize the letters of the alphabet and difficulties in designating the direction of black abstract symbols such as the tumbling ‘E’ or Landolt ‘C’, which the subjects were prone to lose interest in. The visual acuity score may be recorded in different notations:decimal acuity and logMAR. These two notations can be easily converted each other in the new eye chart. The measurements of this new chart not only showed a significant correlation and a good consistency with the international standard logarithmic visual acuity chart (r=0.932, P<0.01, but also indicated a high test-retest reliability (89% of retest scores were within 0.1logMAR units of the initial test score.CONCLUSION: The results of this study support the validity and reliability of distance visual acuity measurements using the new eye chart in

  7. Making SPC easier with zone control charts

    International Nuclear Information System (INIS)

    Lanning, B.

    1995-01-01

    The zone control chart is a simple, easy to learn statistical process control (SPC) tool that can be applied to any process where the data are normally distributed. Several Shewhart runs rules are incorporated into a simple scoring system, with a single rule to determine when a process is out of control. Zone charts have average run lengths (ARLs) for detecting shifts in the process mean which, for most cases, are uniformly better than the standard control charts. This paper presents the simplified methodology behind the zone control chart

  8. Comparative limnology of strip-mine lakes

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, J D

    1964-01-01

    Lakes were classified according to chemical properties. The concentration of the ferric iron oxides was responsible for a reddish-black turbidity which, in turn, played a major role in the thermal stratification of red strip-mine lakes. Owing to the lack of measurable turbidity and as a result of selective absorption of visible solar radiation, other strip-mine lakes appeared blue in color. The annual heat budget and the summer heat budget are essentially equivalent under saline conditions. Regardless of the physical and chemical conditions of the strip-mine lakes, heat income was a function of the circulating water mass. The progressive oxidation and precipitation of the iron oxides is the key to the classification of strip-mine lakes.

  9. Patterns in Patient Access and Utilization of Online Medical Records: Analysis of MyChart

    Science.gov (United States)

    2018-01-01

    Background Electronic patient portals provide a new method for sharing personal medical information with individual patients. Objective Our aim was to review utilization patterns of the largest online patient portal in Canada's largest city. Methods We conducted a 4-year time-trend analysis of aggregated anonymous utilization data of the MyChart patient portal at Sunnybrook Health Sciences Centre in Ontario, Canada, from January 1, 2012, through December 31, 2015. Prespecified analyses examined trends related to day (weekend vs weekday), season (July vs January), year (2012 vs 2015), and an extreme adverse weather event (ice storm of December 20-26, 2013). Primary endpoints included three measures of patient portal activity: registrations, logins, and pageviews. Results We identified 32,325 patients who registered for a MyChart account during the study interval. Time-trend analysis showed no sign of attenuating registrations over time. Logins were frequent, averaged 734 total per day, and showed an increasing trend over time. Pageviews mirrored logins, averaged about 3029 total per day, and equated to about 5 pageviews during the average login. The most popular pageviews were clinical notes, followed by laboratory results and medical imaging reports. All measures of patient activity were lower on weekends compared to weekdays (P<.001) yet showed no significant changes related to seasons or extreme weather. No major security breach, malware attack, or software failure occurred during the study. Conclusions Online patient portals can provide a popular and reliable system for distributing personal medical information to active patients and may merit consideration for hospitals. PMID:29410386

  10. Patterns in Patient Access and Utilization of Online Medical Records: Analysis of MyChart.

    Science.gov (United States)

    Redelmeier, Donald A; Kraus, Nicole C

    2018-02-06

    Electronic patient portals provide a new method for sharing personal medical information with individual patients. Our aim was to review utilization patterns of the largest online patient portal in Canada's largest city. We conducted a 4-year time-trend analysis of aggregated anonymous utilization data of the MyChart patient portal at Sunnybrook Health Sciences Centre in Ontario, Canada, from January 1, 2012, through December 31, 2015. Prespecified analyses examined trends related to day (weekend vs weekday), season (July vs January), year (2012 vs 2015), and an extreme adverse weather event (ice storm of December 20-26, 2013). Primary endpoints included three measures of patient portal activity: registrations, logins, and pageviews. We identified 32,325 patients who registered for a MyChart account during the study interval. Time-trend analysis showed no sign of attenuating registrations over time. Logins were frequent, averaged 734 total per day, and showed an increasing trend over time. Pageviews mirrored logins, averaged about 3029 total per day, and equated to about 5 pageviews during the average login. The most popular pageviews were clinical notes, followed by laboratory results and medical imaging reports. All measures of patient activity were lower on weekends compared to weekdays (Psecurity breach, malware attack, or software failure occurred during the study. Online patient portals can provide a popular and reliable system for distributing personal medical information to active patients and may merit consideration for hospitals. ©Donald A Redelmeier, Nicole C Kraus. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 06.02.2018.

  11. Google Charts Testing | CRDI - Centre de recherches pour le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Google Charts Testing. The following item is a demo of Google GeoChart. Please note that geo chart can only recognize country name or city name rather than location or address (that is google my map's expertise). Additionally, Geo chart does support title and legend. To render geo chart properly, please get a ...

  12. NOAA Seamless Raster Navigational Charts (RNC)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NOAA Seamless Raster Chart Server provides a seamless collarless mosaic of the NOAA Raster Navigational Charts (RNC). The RNC are a collection of approximately...

  13. prepare_taxa_charts.py: A Python program to automate generation of publication ready taxonomic pie chart images from QIIME.

    Science.gov (United States)

    Lakhujani, Vijay; Badapanda, Chandan

    2017-06-01

    QIIME (Quantitative Insights Into Microbial Ecology) is one of the most popular open-source bioinformatics suite for performing metagenome, 16S rRNA amplicon and Internal Transcribed Spacer (ITS) data analysis. Although, it is very comprehensive and powerful tool, it lacks a method to provide publication ready taxonomic pie charts. The script plot_taxa_summary . py bundled with QIIME generate a html file and a folder containing taxonomic pie chart and legend as separate images. The images have randomly generated alphanumeric names. Therefore, it is difficult to associate the pie chart with the legend and the corresponding sample identifier. Even if the option to have the legend within the html file is selected while executing plot_taxa_summary . py , it is very tedious to crop a complete image (having both the pie chart and the legend) due to unequal image sizes. It requires a lot of time to manually prepare the pie charts for multiple samples for publication purpose. Moreover, there are chances of error while identifying the pie chart and legend pair due to random alphanumeric names of the images. To bypass all these bottlenecks and make this process efficient, we have developed a python based program, prepare_taxa_charts . py , to automate the renaming, cropping and merging of taxonomic pie chart and corresponding legend image into a single, good quality publication ready image. This program not only augments the functionality of plot_taxa_summary . py but is also very fast in terms of CPU time and user friendly.

  14. A paediatric X-ray exposure chart

    Energy Technology Data Exchange (ETDEWEB)

    Knight, Stephen P, E-mail: stephen.knight@health.qld.gov.au [Department of Medical Imaging, Royal Children' s Hospital, Brisbane, Queensland (Australia)

    2014-09-15

    The aim of this review was to develop a radiographic optimisation strategy to make use of digital radiography (DR) and needle phosphor computerised radiography (CR) detectors, in order to lower radiation dose and improve image quality for paediatrics. This review was based on evidence-based practice, of which a component was a review of the relevant literature. The resulting exposure chart was developed with two distinct groups of exposure optimisation strategies – body exposures (for head, trunk, humerus, femur) and distal extremity exposures (elbow to finger, knee to toe). Exposure variables manipulated included kilovoltage peak (kVp), target detector exposure and milli-ampere-seconds (mAs), automatic exposure control (AEC), additional beam filtration, and use of antiscatter grid. Mean dose area product (DAP) reductions of up to 83% for anterior–posterior (AP)/posterior–anterior (PA) abdomen projections were recorded postoptimisation due to manipulation of multiple-exposure variables. For body exposures, the target EI and detector exposure, and thus the required mAs were typically 20% less postoptimisation. Image quality for some distal extremity exposures was improved by lowering kVp and increasing mAs around constant entrance skin dose. It is recommended that purchasing digital X-ray equipment with high detective quantum efficiency detectors, and then optimising the exposure chart for use with these detectors is of high importance for sites performing paediatric imaging. Multiple-exposure variables may need to be manipulated to achieve optimal outcomes.

  15. Superconducting nano-strip particle detectors

    International Nuclear Information System (INIS)

    Cristiano, R; Ejrnaes, M; Casaburi, A; Zen, N; Ohkubo, M

    2015-01-01

    We review progress in the development and applications of superconducting nano-strip particle detectors. Particle detectors based on superconducting nano-strips stem from the parent devices developed for single photon detection (SSPD) and share with them ultra-fast response times (sub-nanosecond) and the ability to operate at a relatively high temperature (2–5 K) compared with other cryogenic detectors. SSPDs have been used in the detection of electrons, neutral and charged ions, and biological macromolecules; nevertheless, the development of superconducting nano-strip particle detectors has mainly been driven by their use in time-of-flight mass spectrometers (TOF-MSs) where the goal of 100% efficiency at large mass values can be achieved. Special emphasis will be given to this case, reporting on the great progress which has been achieved and which permits us to overcome the limitations of existing mass spectrometers represented by low detection efficiency at large masses and charge/mass ambiguity. Furthermore, such progress could represent a breakthrough in the field. In this review article we will introduce the device concept and detection principle, stressing the peculiarities of the nano-strip particle detector as well as its similarities with photon detectors. The development of parallel strip configuration is introduced and extensively discussed, since it has contributed to the significant progress of TOF-MS applications. (paper)

  16. Depletive stripping chronopotentiometry : a major step forward in electrochemical stripping techniques for metal ion speciation analysis

    NARCIS (Netherlands)

    Town, R.M.; Leeuwen, van H.P.

    2004-01-01

    A comparative evaluation of the utility of the various modes of stripping chronopotentiometry (SCP) for trace metal speciation analysis is presented in the broad context of stripping voltammetric techniques. The remarkable fundamental advantages of depletive SCP at scanned deposition potential

  17. Ductility of reinforced concrete columns confined with stapled strips

    International Nuclear Information System (INIS)

    Tahir, M.F.; Khan, Q.U.Z.; Shabbir, F.; Sharif, M.B.; Ijaz, N.

    2015-01-01

    Response of three 150x150x450mm short reinforced concrete (RC) columns confined with different types of confining steel was investigated. Standard stirrups, strips and stapled strips, each having same cross-sectional area, were employed as confining steel around four comer column bars. Experimental work was aimed at probing into the affect of stapled strip confinement on post elastic behavior and ductility level under cyclic axial load. Ductility ratios, strength enhancement factor and core concrete strengths were compared to study the affect of confinement. Results indicate that strength enhancement in RC columns due to strip and stapled strip confinement was not remarkable as compared to stirrup confined column. It was found that as compared to stirrup confined column, stapled strip confinement enhanced the ductility of RC column by 183% and observed axial capacity of stapled strip confined columns was 41 % higher than the strip confined columns. (author)

  18. Potential profile in a conducting polymer strip

    DEFF Research Database (Denmark)

    Bay, Lasse; West, Keld; Vlachopoulos, Nikolaos

    2002-01-01

    Many conjugated polymers show an appreciable difference in volume between their oxidized and reduced forms. This property can be utilized in soft electrochemically driven actuators, "artificial muscles". Several geometries have been proposed for the conversion of the volume expansion into useful...... mechanical work. In a particularly simple geometry, the length change of polymer strips is exploited. The polymer strips are connected to the driving circuit at the end of the strip that is attached to the support of the device. The other end of the strip is connected to the load. The advantage of this set...

  19. Study on lifetime of C stripping foils

    International Nuclear Information System (INIS)

    Zhang Hongbin; Lu Ziwei; Zhao Yongtao; Li Zhankui; Xu Hushan; Xiao Guoqing; Wang Yuyu; Zhang Ling; Li Longcai; Fang Yan

    2007-01-01

    The carbon stripping foils can be prepared with the AC and DC arc discharge methods, or even sandwiched with AC-DC alternative layers. The lifetime of the carbon stripping foils of 19 μg/cm 2 prepared with different methods and/or structures was measured. The factors affecting the bombarding lifetime of the carbon stripping foils, especially the method of the foil preparation and the structure of the carbon stripping foils, were discussed. It is observed that the foils prepared with the DC arc discharge method have a longer bombarding lifetime than those prepared with the AC arc discharge method. (authors)

  20. The making of Andersen’s liquefaction chart

    OpenAIRE

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    2017-01-01

    Andersen’s chart (Andersen & Berre, 1999) is a graphical method of observing cyclic soil response. It allows observing soil response to various stress amplitudes that can lead to liquefaction, excess plastic deformation stabilizing soil response.The process of obtaining the original chart has been improved. Algorithm based approximation is introduced. Pore pressure dependent ultimate bearing capacity normalization factor is introduced to normalize the chart.

  1. Simultaneous determination of trace-levels of alloying zinc and copper by semi-mercury-free potentiometric stripping analysis with chemometric data treatment

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Hansen, Elo Harald

    1998-01-01

    Assays of copper and zinc in brass samples were performed by Semi-Mercury Free Potentiometric Stripping Analysis (S-MF PSA) using a thin-film mercury covered glassy-carbon working electrode and dissolved oxygen as oxidizing agent during the stripping step. The stripping peak transients were...... resolved by chemometrics which enabled simultaneous determination of both the copper and the zinc concentrations, thereby eliminating the conventional necessary pretreatment of the sample solution, such as initial addition of Ga(III) or solvent extraction of copper. The brass samples were diluted...... by factors in the range 2.104 - 5.105 which resulted in quantification of the copper and of zinc contents comparable to the specified values within 10%. On the basis of the chemometric treatment, an empirical expression is deduced relating the stripping time to the recorded potential....

  2. 9 CFR 318.307 - Record review and maintenance.

    Science.gov (United States)

    2010-01-01

    ... Section 318.307 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY; MANDATORY MEAT AND POULTRY PRODUCTS INSPECTION AND VOLUNTARY... Canning and Canned Products § 318.307 Record review and maintenance. (a) Process records. Charts from...

  3. HydroHillChart – Francis module. Software used to Calculate the Hill Chart of the Francis Hydraulic Turbines

    Directory of Open Access Journals (Sweden)

    Dorian Nedelcu

    2015-07-01

    Full Text Available The paper presents the Hydro Hill Chart - Francis module application, used to calculate the hill chart of the Pelton, Francis and Kaplan hydraulic turbine models, by processing the data measured on the stand. After describing the interface and menu, the input data is graphically presented and the universal characteristic for measuring scenarios ao=const. and n11=const is calculated. Finally, the two calculated hill charts are compared through a graphical superimposition of the isolines.

  4. Transmission Line Adapted Analytical Power Charts Solution

    Science.gov (United States)

    Sakala, Japhet D.; Daka, James S. J.; Setlhaolo, Ditiro; Malichi, Alec Pulu

    2017-08-01

    The performance of a transmission line has been assessed over the years using power charts. These are graphical representations, drawn to scale, of the equations that describe the performance of transmission lines. Various quantities that describe the performance, such as sending end voltage, sending end power and compensation to give zero voltage regulation, may be deduced from the power charts. Usually required values are read off and then converted using the appropriate scales and known relationships. In this paper, the authors revisit this area of circle diagrams for transmission line performance. The work presented here formulates the mathematical model that analyses the transmission line performance from the power charts relationships and then uses them to calculate the transmission line performance. In this proposed approach, it is not necessary to draw the power charts for the solution. However the power charts may be drawn for the visual presentation. The method is based on applying derived equations and is simple to use since it does not require rigorous derivations.

  5. Chart of the nuclides - Strasbourg 1990

    International Nuclear Information System (INIS)

    Antony, M.S.

    1991-01-01

    Data were compiled for a nuclide chart over the last two years. The compilation is complete to the end of September 1990. The chart includes about 30000 data. Decay modes are represented by colours. Announcement capabilities and prices are given. (G.P.) 3 refs

  6. Obtaining the Andersen's chart, triangulation algorithm

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    Andersen’s chart (Andersen & Berre, 1999) is a graphical method of observing cyclic soil response. It allows observing soil response to various stress amplitudes that can lead to liquefaction, excess plastic deformation or stabilizing soil response. The process of obtaining the original chart has...

  7. 49 CFR 236.718 - Chart, dog.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Chart, dog. 236.718 Section 236.718 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.718 Chart, dog. A...

  8. Quality control chart for crushed granite concrete

    Directory of Open Access Journals (Sweden)

    Ewa E. DESMOND

    2016-07-01

    Full Text Available A chart for assessing in-situ grade (strength of concrete, has been developed in this study. Four grades of concrete after the Nigerian General Specification for Roads and bridges (NGSRB-C20, C25, C30 and C35, is studied at different water-cement ratios for medium and high slump range. The concrete mixes are made from crushed granite rock as coarse aggregate with river sand as fine aggregate. Compression test on specimens are conducted at curing age of 1, 3, 7, 14, 21, 28 and 56 days. Results on concrete workability from slump values, and water-cement ratios revealed that specimens with lower water-cement ratio were less workable but had higher strength, compared to mixes with higher water cement ratio. A simple algorithm using nonlinear regression analysis performed on each experimental data set produced Strength-Age (S-A curves which were used to establish a quality control chart. The accuracy of these curves were evaluated by computing average absolute error (AAS, the error of estimate (EoE and the average absolute error of estimate (Abs EoE for each concrete mix. These were done based on the actual average experimental strengths to measure how close the predicted values are to the experimental data set. The absolute average error of estimate (Abs. EoE recorded was less than ±10% tolerance zone for concrete works.

  9. Ultrasonic examination of JBK-75 strip material

    International Nuclear Information System (INIS)

    Cook, K.V.; Cunningham, R.A. Jr.; Lewis, J.C.; McClung, R.W.

    1982-12-01

    An ultrasonic inspection system was assembled to inspect the JBK-75 stainless steel sheath material (for the Large Coil Project) for the Westinghouse-Airco superconducting magnet program. The mechanical system provided for handling the 180-kg (400-lb) coils of strip material [1.6 mm thick by 78 mm wide by 90 to 120 m long (0.064 by 3.07 in. by 300 to 400 ft)], feeding the strip through the ultrasonic inspection and cleaning stations, and respooling the coils. We inspected 54 coils of strip for both longitudinal and laminar flaws. Simulated flaws were used to calibrate both inspections. Saw-cut notches [0.28 mm deep (0.011 in., about 17% of the strip thickness)] were used to calibrate the longitudinal flaw inspections; 1.59-mm-diam (0.063-in.) flat-bottom holes drilled halfway through a calibration strip were used to calibrate the laminar flaw tests

  10. Hardness of approximation for strip packing

    DEFF Research Database (Denmark)

    Adamaszek, Anna Maria; Kociumaka, Tomasz; Pilipczuk, Marcin

    2017-01-01

    Strip packing is a classical packing problem, where the goal is to pack a set of rectangular objects into a strip of a given width, while minimizing the total height of the packing. The problem has multiple applications, for example, in scheduling and stock-cutting, and has been studied extensively......)-approximation by two independent research groups [FSTTCS 2016,WALCOM 2017]. This raises a questionwhether strip packing with polynomially bounded input data admits a quasi-polynomial time approximation scheme, as is the case for related twodimensional packing problems like maximum independent set of rectangles or two...

  11. U.S. Pacific Command > Organization > Organization Chart

    Science.gov (United States)

    Responsibility USPACOM Previous Commanders Organization Organization Chart Media News Flickr Photos Video Directory Media Inquiries Home : Organization : Organization Chart About DoD DoD Careers Join the Military

  12. Smart Book Charts

    Science.gov (United States)

    Chinnapongse, Ronald L.

    2015-01-01

    Smart book charts for TPSM: Heatshield for Extreme Entry Environment Technology (HEEET), Conformal Ablative TPS (CA-TPS), 3D Woven Multifunctional Ablative TPS (3D MAT), and Adaptable, Deployable, Entry and Placement Technology (ADEPT).

  13. Chart of the nuclides

    International Nuclear Information System (INIS)

    Yoshizawa, Y.; Horiguchi, T.; Yamada, M.

    1980-01-01

    In this chart, four colors are use to classify nuclides according to their half-lives. The different symbols are also to show the decay modes and their percentage in each nuclide. Four tables are provided on the back of the chart. Table 1 is the ordinary periodic Table. Table 2 provides fundamental constants used for nuclear physics. Tables 3 lists the physical constants (mean density, ionization potential, melting point, and boiling point) of all elements. Table 4 provides the gamma-ray intensity standards. Half-lives, energy, relative intensity, and intensity per decay are list for 33 nuclides. (J.P.N.)

  14. Transfusion and blood donation in comic strips.

    Science.gov (United States)

    Lefrère, Jean-Jacques; Danic, Bruno

    2013-07-01

    The representation of blood transfusion and donation of blood in the comic strip has never been studied. The comic strip, which is a relatively recent art, emerged in the 19th century before becoming a mass medium during the 20th century. We have sought, by calling on collectors and using the resources of Internet, comic strips devoted, wholly or in part, to the themes of transfusion and blood donation. We present some of them here in chronologic order, indicating the title, country of origin, year of publication, and names of authors. The theme of the superhero using transfusion to transmit his virtues or his powers is repeated throughout the 20th century in North American comic strips. More recently, comic strips have been conceived from the outset with a promotional aim. They perpetuate positive images and are directed toward a young readership, wielding humor to reduce the fear of venipuncture. Few comic strips denounce the abuse of the commercialization of products derived from the human body. The image of transfusion and blood donation given by the comic strips is not to be underestimated because their readership is primarily children, some of whom will become blood donors. Furthermore, if some readers are transfused during their lives, the impact of a memory more or less conscious of these childhood readings may resurface, both in hopes and in fears. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. 47 CFR 73.333 - Engineering charts.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Engineering charts. 73.333 Section 73.333 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES FM Broadcast Stations § 73.333 Engineering charts. This section consists of the following Figures 1, 1a, 2, and...

  16. Downhole microseismic signal-to-noise ratio enhancement via strip matching shearlet transform

    Science.gov (United States)

    Li, Juan; Ji, Shuo; Li, Yue; Qian, Zhihong; Lu, Weili

    2018-04-01

    Shearlet transform has been proved effective in noise attenuation. However, because of the low magnitude and high frequency of downhole microseismic signals, the coefficient values of valid signals and noise are similar in the shearlet domain. As a result, it is hard to suppress the noise. In this paper, we present a novel signal-to-noise ratio enhancement scheme called strip matching shearlet transform. The method takes into account the directivity of microseismic events and shearlets. Through strip matching, the matching degree in direction between them has been promoted. Then the coefficient values of valid signals are much larger than those of the noise. Consequently, we can separate them well with the help of thresholding. The experimental results on both synthetic records and field data illustrate that our proposed method preserves the useful components and attenuates the noise well.

  17. Two-dimensional phase fraction charts

    International Nuclear Information System (INIS)

    Morral, J.E.

    1984-01-01

    A phase fraction chart is a graphical representation of the amount of each phase present in a system as a function of temperature, composition or other variable. Examples are phase fraction versus temperature charts used to characterize specific alloys and as a teaching tool in elementary texts, and Schaeffler diagrams used to predict the amount of ferrite in stainless steel welds. Isothermal-transformation diagrams (TTT diagrams) are examples that give phase (or microconstituent) amount versus temperature and time. The purpose of this communication is to discuss the properties of two-dimensional phase fraction charts in more general terms than have been reported before. It is shown that they can represent multi-component, multiphase equilibria in a way which is easier to read and which contains more information than the isotherms and isopleths of multi-component phase diagrams

  18. 15 CFR 738.3 - Commerce Country Chart structure.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Commerce Country Chart structure. 738.3 Section 738.3 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade... COMMERCE CONTROL LIST OVERVIEW AND THE COUNTRY CHART § 738.3 Commerce Country Chart structure. (a) Scope...

  19. Preparation of exposures charts for X-ray tubes

    International Nuclear Information System (INIS)

    Zoofan, B.

    1988-01-01

    An exposure chart is a fundamental graph which provides guidance of the exposure conditions in relation to the thickness for a given specimen. It must be prepared specially for the X-ray unit and the type of the film to be used. Although exposure charts are available for each particular X-ray tube from its manufacturer, individual radiographic laboratory should be able to prepare its own exposure charts in a precise manner. Here a typical procedure to prepare such a chart is provided in a practical way with some necessary recommendations

  20. A PIP chart for nuclear plant safety

    International Nuclear Information System (INIS)

    Suzuki, Tatsujiro; Yamaoka, Taiji

    1992-01-01

    While it is known that social and political aspects of nuclear safety issues are important, little study has been done on identifying the breadth of stakeholders whose policies have important influences over nuclear plant safety in a comprehensive way. The objectives of this study are to develop a chart that visually identifies important stakeholders and their policies and illustrates these influences in a hierarchical representation so that the relationship between stakeholders and nuclear safety will be better understood. This study is based on a series of extensive interviews with major stakeholders, such as nuclear plant managers, corporate planning vice presidents, state regulators, news media, and public interest groups, and focuses on one US nuclear power plant. Based on the interview results, the authors developed a conceptual policy influence paths (PIP) chart. The PIP chart illustrates the hierarchy of influence among stakeholders. The PIP chart is also useful in identifying possible stakeholders who can be easily overlooked without the PIP chart. In addition, it shows that influence flow is circular rather than linear in one direction

  1. SU-E-T-408: Evaluation of the Type and Frequency of Variations Discovered During Routine Secondary Patient Chart Review

    International Nuclear Information System (INIS)

    Hardin, M; Harrison, A; Lockamy, V; Li, J; Peng, C; Potrebko, P; Yu, Y; Doyle, L; Cao, J

    2015-01-01

    Purpose: Desire to improve efficiency and throughput inspired a review of our physics chart check procedures. Departmental policy mandates plan checks pre-treatment, after first treatment and weekly every 3–5 days. This study examined the effectiveness of the “after first” check with respect to improving patient safety and clinical efficiency. Type and frequency of variations discovered during this redundant secondary review was examined over seven months. Methods: A community spreadsheet was created to record variations in care discovered during chart review following the first fraction of treatment and before the second fraction (each plan reviewed prior to treatment). Entries were recorded from August 2014 through February 2015, amounting to 43 recorded variations out of 906 reviewed charts. The variations were divided into categories and frequencies were assessed month-to-month. Results: Analysis of recorded variations indicates an overall variation rate of 4.7%. The initial rate was 13.5%; months 2–7 average 3.7%. The majority of variations related to discrepancies in documentation at 46.5%, followed by prescription, plan deficiency, and dose tracking related variations at 25.5%, 12.8%, and 12.8%, respectively. Minor variations (negligible consequence on patient treatment) outweighed major variations 3 to 1. Conclusion: This work indicates that this redundant secondary check is effective. The first month spike in rates could be due to the Hawthorne/observer effect, but the consistent 4% variation rate suggests the need for periodical re-training on variations noted as frequent to improve awareness and quality of the initial chart review process, which may lead to improved treatment quality, patient safety and increased clinical efficiency. Utilizing these results, a continuous quality improvement process following Deming’s Plan-Do-Study-Act (PDSA) methodology was generated. The first iteration of this PDSA was adding a specific dose tracking

  2. SU-E-T-408: Evaluation of the Type and Frequency of Variations Discovered During Routine Secondary Patient Chart Review

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, M; Harrison, A; Lockamy, V; Li, J; Peng, C; Potrebko, P; Yu, Y; Doyle, L; Cao, J [Thomas Jefferson University, Philadelphia, PA (United States)

    2015-06-15

    Purpose: Desire to improve efficiency and throughput inspired a review of our physics chart check procedures. Departmental policy mandates plan checks pre-treatment, after first treatment and weekly every 3–5 days. This study examined the effectiveness of the “after first” check with respect to improving patient safety and clinical efficiency. Type and frequency of variations discovered during this redundant secondary review was examined over seven months. Methods: A community spreadsheet was created to record variations in care discovered during chart review following the first fraction of treatment and before the second fraction (each plan reviewed prior to treatment). Entries were recorded from August 2014 through February 2015, amounting to 43 recorded variations out of 906 reviewed charts. The variations were divided into categories and frequencies were assessed month-to-month. Results: Analysis of recorded variations indicates an overall variation rate of 4.7%. The initial rate was 13.5%; months 2–7 average 3.7%. The majority of variations related to discrepancies in documentation at 46.5%, followed by prescription, plan deficiency, and dose tracking related variations at 25.5%, 12.8%, and 12.8%, respectively. Minor variations (negligible consequence on patient treatment) outweighed major variations 3 to 1. Conclusion: This work indicates that this redundant secondary check is effective. The first month spike in rates could be due to the Hawthorne/observer effect, but the consistent 4% variation rate suggests the need for periodical re-training on variations noted as frequent to improve awareness and quality of the initial chart review process, which may lead to improved treatment quality, patient safety and increased clinical efficiency. Utilizing these results, a continuous quality improvement process following Deming’s Plan-Do-Study-Act (PDSA) methodology was generated. The first iteration of this PDSA was adding a specific dose tracking

  3. Development of floating strip micromegas detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, Jonathan

    2014-04-28

    Micromegas are high-rate capable, high-resolution micro-pattern gaseous detectors. Square meter sized resistive strip Micromegas are foreseen as replacement of the currently used precision tracking detectors in the Small Wheel, which is part of the forward region of the ATLAS muon spectrometer. The replacement is necessary to ensure tracking and triggering performance of the muon spectrometer after the luminosity increase of the Large Hadron Collider beyond its design value of 10{sup 34} cm{sup -2}s{sup -1} around 2020. In this thesis a novel discharge tolerant floating strip Micromegas detector is presented and described. By individually powering copper anode strips, the effects of a discharge are confined to a small region of the detector. This reduces the impact of discharges on the efficiency by three orders of magnitude, compared to a standard Micromegas. The physics of the detector is studied and discussed in detail. Several detectors are developed: A 6.4 x 6.4 cm{sup 2} floating strip Micromegas with exchangeable SMD capacitors and resistors allows for an optimization of the floating strip principle. The discharge behavior is investigated on this device in depth. The microscopic structure of discharges is quantitatively explained by a detailed detector simulation. A 48 x 50 cm{sup 2} floating strip Micromegas is studied in high energy pion beams. Its homogeneity with respect to pulse height, efficiency and spatial resolution is investigated. The good performance in high-rate background environments is demonstrated in cosmic muon tracking measurements with a 6.4 x 6.4 cm{sup 2} floating strip Micromegas under lateral irradiation with 550 kHz 20 MeV proton beams. A floating strip Micromegas doublet with low material budget is developed for ion tracking without limitations from multiple scattering in imaging applications during medical ion therapy. Highly efficient tracking of 20 MeV protons at particle rates of 550 kHz is possible. The reconstruction of the

  4. Development of floating strip micromegas detectors

    International Nuclear Information System (INIS)

    Bortfeldt, Jonathan

    2014-01-01

    Micromegas are high-rate capable, high-resolution micro-pattern gaseous detectors. Square meter sized resistive strip Micromegas are foreseen as replacement of the currently used precision tracking detectors in the Small Wheel, which is part of the forward region of the ATLAS muon spectrometer. The replacement is necessary to ensure tracking and triggering performance of the muon spectrometer after the luminosity increase of the Large Hadron Collider beyond its design value of 10 34 cm -2 s -1 around 2020. In this thesis a novel discharge tolerant floating strip Micromegas detector is presented and described. By individually powering copper anode strips, the effects of a discharge are confined to a small region of the detector. This reduces the impact of discharges on the efficiency by three orders of magnitude, compared to a standard Micromegas. The physics of the detector is studied and discussed in detail. Several detectors are developed: A 6.4 x 6.4 cm 2 floating strip Micromegas with exchangeable SMD capacitors and resistors allows for an optimization of the floating strip principle. The discharge behavior is investigated on this device in depth. The microscopic structure of discharges is quantitatively explained by a detailed detector simulation. A 48 x 50 cm 2 floating strip Micromegas is studied in high energy pion beams. Its homogeneity with respect to pulse height, efficiency and spatial resolution is investigated. The good performance in high-rate background environments is demonstrated in cosmic muon tracking measurements with a 6.4 x 6.4 cm 2 floating strip Micromegas under lateral irradiation with 550 kHz 20 MeV proton beams. A floating strip Micromegas doublet with low material budget is developed for ion tracking without limitations from multiple scattering in imaging applications during medical ion therapy. Highly efficient tracking of 20 MeV protons at particle rates of 550 kHz is possible. The reconstruction of the track inclination in a single

  5. A case study in Gantt charts as historiophoty: A century of psychology at the University of Alberta.

    Science.gov (United States)

    Dawson, Michael R W

    2013-05-01

    History is typically presented as historiography, where historians communicate via the written word. However, some historians have suggested alternative formats for communicating and thinking about historical information. One such format is known as historiophoty, which involves using a variety of visual images to represent history. The current article proposes that a particular type of graph, known as a Gantt chart, is well suited for conducting historiophoty. When used to represent history, Gantt charts provide a tremendous amount of information. Furthermore, the spatial nature of Gantt charts permits other kinds of spatial operations to be performed on them. This is illustrated with a case study of the history of a particular psychology department. The academic year 2009-2010 marked the centennial of psychology at the University of Alberta. This centennial was marked by compiling a list of its full-time faculty members for each year of its history. This historiography was converted into historiophoty by using it as the source for the creation of a Gantt chart. The current article shows how the history of psychology at the University of Alberta is revealed by examining this Gantt chart in a variety of different ways. This includes computing simple descriptive statistics from the chart, creating smaller versions of the Gantt to explore departmental demographics, and using image processing methods to provide measures of departmental stability throughout its history. (PsycINFO Database Record (c) 2013 APA, all rights reserved).

  6. 7 CFR 29.6128 - Straight Stripped (X Group).

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Straight Stripped (X Group). 29.6128 Section 29.6128... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.6128 Straight Stripped (X Group). This group consists of..., and tolerances X1 Fine Quality Straight Stripped. Heavy, ripe, firm, semielastic, normal strength and...

  7. Evaluation of statistical control charts for on-line radiation monitoring

    International Nuclear Information System (INIS)

    Hughes, L.D.; DeVol, T.A.

    2008-01-01

    Statistical control charts are presented for the evaluation of time series radiation counter data from flow cells used for monitoring of low levels of 99 TcO 4 - in environmental solutions. Control chart methods consisted of the 3-sigma (3σ) chart, the cumulative sum (CUSUM) chart, and the exponentially weighted moving average (EWMA) chart. Each method involves a control limit based on the detector background which constitutes the detection limit. Both the CUSUM and EWMA charts are suitable to detect and estimate sample concentration requiring less solution volume than when using a 3? control chart. Data presented here indicate that the overall accuracy and precision of the CUSUM method is the best. (author)

  8. Apparatus for measuring profile thickness of strip material

    International Nuclear Information System (INIS)

    Hold, A.C.

    1982-01-01

    Apparatus for measuring the thickness profile of steel strip comprises a radiation source reciprocally movable in a stepwise fashion (by a belt) across the strip width on one side thereof and a single elongated detector on the other side of the strip aligned with the scanning source. This detector may be a fluorescent scintillator detector or an ionisation chamber. Means are provided for sensing the degree of excitation in the detector in synchronism with the scanning source whereby to provide an output representative of the thickness profile of the strip. (author)

  9. Stocking chart for upland central hardwoods

    Science.gov (United States)

    Martin E. Dale; Donald E. Hilt

    1989-01-01

    The upland hardwoods stocking chart, introduced by Gingrich in 1967, has become one of the forest manager's most useful tools. The chart allows you to determine the condition of the present stand in relation to a stocking standard. The stocking of a stand is extremely helpful in prescribing various silvicultural treatments such as intermediate thinnings,...

  10. Stability of barotropic vortex strip on a rotating sphere.

    Science.gov (United States)

    Sohn, Sung-Ik; Sakajo, Takashi; Kim, Sun-Chul

    2018-02-01

    We study the stability of a barotropic vortex strip on a rotating sphere, as a simple model of jet streams. The flow is approximated by a piecewise-continuous vorticity distribution by zonal bands of uniform vorticity. The linear stability analysis shows that the vortex strip becomes stable as the strip widens or the rotation speed increases. When the vorticity constants in the upper and the lower regions of the vortex strip have the same positive value, the inner flow region of the vortex strip becomes the most unstable. However, when the upper and the lower vorticity constants in the polar regions have different signs, a complex pattern of instability is found, depending on the wavenumber of perturbations, and interestingly, a boundary far away from the vortex strip can be unstable. We also compute the nonlinear evolution of the vortex strip on the rotating sphere and compare with the linear stability analysis. When the width of the vortex strip is small, we observe a good agreement in the growth rate of perturbation at an early time, and the eigenvector corresponding to the unstable eigenvalue coincides with the most unstable part of the flow. We demonstrate that a large structure of rolling-up vortex cores appears in the vortex strip after a long-time evolution. Furthermore, the geophysical relevance of the model to jet streams of Jupiter, Saturn and Earth is examined.

  11. Stability of barotropic vortex strip on a rotating sphere

    Science.gov (United States)

    Sohn, Sung-Ik; Sakajo, Takashi; Kim, Sun-Chul

    2018-02-01

    We study the stability of a barotropic vortex strip on a rotating sphere, as a simple model of jet streams. The flow is approximated by a piecewise-continuous vorticity distribution by zonal bands of uniform vorticity. The linear stability analysis shows that the vortex strip becomes stable as the strip widens or the rotation speed increases. When the vorticity constants in the upper and the lower regions of the vortex strip have the same positive value, the inner flow region of the vortex strip becomes the most unstable. However, when the upper and the lower vorticity constants in the polar regions have different signs, a complex pattern of instability is found, depending on the wavenumber of perturbations, and interestingly, a boundary far away from the vortex strip can be unstable. We also compute the nonlinear evolution of the vortex strip on the rotating sphere and compare with the linear stability analysis. When the width of the vortex strip is small, we observe a good agreement in the growth rate of perturbation at an early time, and the eigenvector corresponding to the unstable eigenvalue coincides with the most unstable part of the flow. We demonstrate that a large structure of rolling-up vortex cores appears in the vortex strip after a long-time evolution. Furthermore, the geophysical relevance of the model to jet streams of Jupiter, Saturn and Earth is examined.

  12. Medication documentation in a primary care network serving North Carolina medicaid patients: results of a cross-sectional chart review

    Directory of Open Access Journals (Sweden)

    Olson Matthew D

    2012-08-01

    Full Text Available Abstract Background Medical records that do not accurately reflect the patient’s current medication list are an open invitation to errors and may compromise patient safety. Methods This cross-sectional study compares primary care provider (PCP medication lists and pharmacy claims for 100 patients seen in 8 primary care practices and examines the association of congruence with demographic, clinical, and practice characteristics. Medication list congruence was measured as agreement of pharmacy claims with the entire PCP chart, including current medication list, visit notes, and correspondence sections. Results Congruence between pharmacy claims and the PCP chart was 65%. Congruence was associated with large chronic disease burden, frequent PCP visits, group practice, and patient age ≥45 years. Conclusion Agreement of medication lists between the PCP chart and pharmacy records is low. Medication documentation was more accurate among patients who have more chronic conditions, those who have frequent PCP visits, those whose practice has multiple providers, and those at least 45 years of age. Improved congruence among patients with multiple chronic conditions and in group practices may reflect more frequent visits and reviews by providers.

  13. Square chart of nuclides with the best coordinates

    International Nuclear Information System (INIS)

    Wang Yuying

    2001-01-01

    It analyzes upper limiting feature of even Z=60-82 in different charts of nuclides. It has illustrated that the break line of upper limiting Z=60-82 in the chart of nucleus with proton number Z and neutron number N, parameters Z and H (=N-Z), two new parameters S(=2Z-N) and H, and parameters K (=S-H) and H, in proper order, it shows that the break line trends from the left lower to the right upper, the line alternates with horizontal and vertical, and the line trends from the right lower to the left upper. Here it finds that the square chart of nuclides places the middle among these charts. It shows that nuclei distribution is concentrated, so are scope of whole region of nuclides in the different charts of nuclides

  14. Color Charts, Esthetics, and Subjective Randomness

    Science.gov (United States)

    Sanderson, Yasmine B.

    2012-01-01

    Color charts, or grids of evenly spaced multicolored dots or squares, appear in the work of modern artists and designers. Often the artist/designer distributes the many colors in a way that could be described as "random," that is, without an obvious pattern. We conduct a statistical analysis of 125 "random-looking" art and design color charts and…

  15. Factors affecting hydrocarbon removal by air stripping

    International Nuclear Information System (INIS)

    McFarland, W.E.

    1992-01-01

    This paper includes an overview of the theory of air stripping design considerations and the factors affecting stripper performance. Effects of temperature, contaminant characteristics, stripping tower geometry and air/water ratios on removal performance are discussed. The discussion includes treatment of groundwater contaminated with petroleum hydrocarbons and chlorinated solvents such as TCE and PCE. Control of VOC emissions from air strippers has become a major concern in recent years, due to more stringent restrictions on air quality in many areas. This paper includes an overview of available technology to control air emissions (including activated carbon adsorption, catalytic oxidation and steam stripping) and the effects of air emission control on overall efficiency of the treatment process. The paper includes an overview of the relative performance of various packing materials for air strippers and explains the relative advantages and disadvantages of comparative packing materials. Field conditions affecting selection of packing materials are also discussed. Practical guidelines for the design of air stripping systems are presented, as well as actual case studies of full-scale air stripping projects

  16. Comparative evaluation of diode laser ablation and surgical stripping technique for gingival depigmentation: A clinical and immunohistochemical study.

    Science.gov (United States)

    Bakutra, Gaurav; Shankarapillai, Rajesh; Mathur, Lalit; Manohar, Balaji

    2017-01-01

    There are various treatment modalities to remove the black patches of melanin pigmentation. The aim of the study is to clinically compare the diode laser ablation and surgical stripping technique for gingival depigmentation and to evaluate their effect on the histological changes in melanocyte activity. A total of 40 sites of 20 patients with bilateral melanin hyperpigmentation were treated with the surgical stripping and diode laser ablation technique. Change in Hedin index score, change in area of pigmentation using image analyzing software, pain perception, patient preference of treatment were recorded. All 40 sites were selected for immunohistochemical analysis using HMB-45 immunohistochemical marker. At 12 months post-operative visit, in all sites, repigmentation was observed with different grades of Hedin index. Paired t -test, analysis of variance, and Chi-square tests were used for statistical analysis. Repigmentation in surgical stripping is significantly lesser compared to laser ablation. Lesser numbers of melanocytes were found on immunohistological examination at 12 months postoperatively. Comparison for patient preference and pain indices give statistically significant values for diode laser techniques. Gingival hyperpigmentation is effectively managed by diode laser ablation technique and surgical stripping method. In this study, surgical stripping technique found to be better compared to diode laser ablation.

  17. A new Snellen's visual acuity chart with 'Indian' numerals.

    OpenAIRE

    Al-Salem, M

    1987-01-01

    'Indian' numerals, which are popular among the Arab population, were used to devise a new Snellen's visual acuity chart. The new chart has the advantages of a reading chart. It keeps the patient's interest, does not miss alexic patients, and is quicker to perform. It is also devoid of the many disadvantages of a kinetic response chart (the capital E letter or Landolt's broken rings), especially that of the limited option of test objects.

  18. Karlsruhe nuclide chart - new 9. edition 2015

    Energy Technology Data Exchange (ETDEWEB)

    Soti, Zsolt [European Commission, Joint Research Centre (JRC), Institute for Transuranium Elements (ITU), Postfach 2340, DE-76125 Karlsruhe, (Germany); Magill, Joseph; Pfennig, Gerda; Derher, Raymond [Nucleonica GmbH, c/o European Commission, Postfach 2340, DE-76125 Karlsruhe, (Germany)

    2015-07-01

    Following the success of the 8. Edition of the Karlsruhe Nuclide Chart 2012, a new edition is planned for 2015. Since the 2012 edition, more than 100 nuclides have been discovered and about 1400 nuclides have been updated. In summary, the new 9. edition contains decay and radiation data on approximately 3230 ground state nuclides and 740 isomers from 118 chemical elements. The accompanying booklet provides a detailed explanation of the nuclide box structure used in the Chart. An expanded section contains many additional nuclide decay schemes to aid the user to interpret the highly condensed information in the nuclide boxes. The booklet contains - in addition to the latest values of the physical constants and physical properties - a periodic table of the elements, tables of new and updated nuclides, and a difference chart showing the main changes in the Chart graphically. (authors)

  19. Karlsruhe nuclide chart - new 9. edition 2015

    International Nuclear Information System (INIS)

    Soti, Zsolt; Magill, Joseph; Pfennig, Gerda; Derher, Raymond

    2015-01-01

    Following the success of the 8. Edition of the Karlsruhe Nuclide Chart 2012, a new edition is planned for 2015. Since the 2012 edition, more than 100 nuclides have been discovered and about 1400 nuclides have been updated. In summary, the new 9. edition contains decay and radiation data on approximately 3230 ground state nuclides and 740 isomers from 118 chemical elements. The accompanying booklet provides a detailed explanation of the nuclide box structure used in the Chart. An expanded section contains many additional nuclide decay schemes to aid the user to interpret the highly condensed information in the nuclide boxes. The booklet contains - in addition to the latest values of the physical constants and physical properties - a periodic table of the elements, tables of new and updated nuclides, and a difference chart showing the main changes in the Chart graphically. (authors)

  20. 46 CFR 4.05-15 - Voyage records, retention of.

    Science.gov (United States)

    2010-10-01

    ... room logs, bell books, navigation charts, navigation work books, compass deviation cards, gyro records, stowage plans, records of draft, aids to mariners, night order books, radiograms sent and received, radio... request, to a duly authorized investigating officer, administrative law judge, officer or employee of the...

  1. Magnetic stripping studies for SPL

    CERN Document Server

    Posocco, P; CERN. Geneva. BE Department

    2010-01-01

    Magnetic stripping of H- can seriously enhance the beam losses along the SPL machine. These losses depend on the beam energy, on the beam transverse distribution and on the intensity of the magnetic field. For radioprotection issues the losses must be limited to 1 W/m. In this paper we will concentrate on the stripping phenomena inside the quadrupole magnets with the aim of defining the quadrupole range for the design phase of SPL.

  2. Evaluation of circulating cathodic antigen (CCA strip for diagnosis of urinary schistosomiasis in Hassoba school children, Afar, Ethiopia

    Directory of Open Access Journals (Sweden)

    Ayele B.

    2008-03-01

    Full Text Available A total of 206 urine samples collected from Hassoba Elementary schoolchildren, Afar, Ethiopia, a low Schistosoma haematobium endemic setting, was diagnosed to evaluate the performance of CCA strip using double references, urine filtration technique and urinalysis dipstick (Combur 10 Test® that detect schistosome eggs and blood in urine, respectively. The former was used as a gold standard reference method. Sensitivity, specificity, positive and negative predictive values for the CCA were 52%, 63.8%, 56.7% and 59% respectively, with reference to urine filtration technique whereas these parameters were 50.4%, 62.4%, 55.6% and 57.5% respectively, with reference to Combur 10 Test®. 47 S. haematobium egg-positive children were found negative by CCA strip while 38 egg-negative children were found positive by CCA strip. Moreover, among the pre-tests done in duplicate, inconsistent results were also recorded. Assays were also compared with regard to the cost of equipment and reagents, speed and simplicity of use. Though CCA strip was found to be rapid and could be performed with minimal training, it was found to be expensive (US $ 4.95 per test to use it for large-scale field use even if its diagnostic value would have been satisfactory. Further development and standardization of the CCA strip are required for its applicability for field use. It is also recommended that its cost per strip should be substantially cut down if it is to be used in poor schistosomiasis endemic countries.

  3. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  4. Neonicotinoid insecticide removal by prairie strips in row-cropped watersheds with historical seed coating use

    Science.gov (United States)

    Hladik, Michelle L.; Bradbury, Steven; Schulte, Lisa A.; Helmers, Matthew; Witte, Christopher; Kolpin, Dana W.; Garrett, Jessica D.; Harris, Mary

    2017-01-01

    Neonicotinoids are a widely used class of insecticides that are commonly applied as seed coatings for agricultural crops. Such neonicotinoid use may pose a risk to non-target insects, including pollinators and natural enemies of crop pests, and ecosystems. This study assessed neonicotinoid residues in groundwater, surface runoff water, soil, and native plants adjacent to corn and soybean crop fields with a history of being planted with neonicotinoid-treated seeds from 2008-2013. Data from six sites with the same crop management history, three with and three without in-field prairie strips, were collected in 2015-2016, 2-3 years after neonicotinoid (clothianidin and imidacloprid) seed treatments were last used. Three of the six neonicotinoids analyzed were detected in at least one environmental matrix: the two applied as seed coatings on the fields (clothianidin and imidacloprid) and another widely used neonicotinoid (thiamethoxam). Sites with prairie strips generally had lower concentrations of neonicotinoids: groundwater and footslope soil neonicotinoid concentrations were significantly lower in the sites with prairie strips than those without; mean concentrations for groundwater were 11 and 20 ng/L (p = 0.048) and <1 and 6 ng/g (p = 0.0004) for soil, respectively. Surface runoff water concentrations were not significantly (p = 0.38) different for control sites (44 ng/L) or sites with prairie strips (140 ng/L). Consistent with the decreased inputs of neonicotinoids, concentrations tended to decrease over the sampling timeframe. Two sites recorded concentration increases, however, potentially due to disturbance of previous applications or influence from nearby fields where use of seed treatments continued. There were no detections (limit of detection: 1 ng/g) of neonicotinoids in the foliage or roots of plants comprising prairie strips, indicating a low likelihood of exposure to pollinators and other insects visiting these plants following the cessation of seed

  5. Microstructural research on hot strips of low carbon steel produced by a compact strip production line under different thermal histories

    International Nuclear Information System (INIS)

    Yu Hao; Chen Qixiang; Kang Yonglin; Sun Yi

    2005-01-01

    Coupons with the same composition and thickness (4.0 mm nominal gauge) obtained from hot strips of low carbon steel underwent a series of investigations to analyze the microstructural characteristics and mechanisms responsible for their differences in mechanical properties. Two different industrial technologies were adopted, although the strips used in this research were produced on the same Compact Strip Production (CSP) line. One of the strips was produced with a routine γ→α CSP thermal history, but the other with a γ→α→γ* conventional thermal history. The only difference between them was that one technology had a α→γ* thermal history. Different specimens of both types of strips were prepared for metallographic observation, tensile tests, electron back-scattered diffraction tests and positron annihilation technique tests. Experimental results showed that the differences in mechanical properties could be ascribed to dissimilarities not only in the grain size and textural components but also in dislocation density

  6. High Pressure Water Stripping Using Multi-Orifice Nozzles

    Science.gov (United States)

    Hoppe, David

    1999-01-01

    The use of multi-orifice rotary nozzles greatly increases the speed and stripping effectiveness of high pressure water blasting systems, but also greatly increases the complexity of selecting and optimizing the operating parameters. The rotational speed of the nozzle must be coupled with its transverse velocity as it passes across the surface of the substrate being stripped. The radial and angular positions of each orifice must be included in the analysis of the nozzle configuration. Orifices at the outer edge of the nozzle head move at a faster rate than the orifices located near the center. The energy transmitted to the surface from the impact force of the water stream from an outer orifice is therefore spread over a larger area than energy from an inner orifice. Utilizing a larger diameter orifice in the outer radial positions increases the total energy transmitted from the outer orifice to compensate for the wider distribution of energy. The total flow rate from the combination of all orifices must be monitored and should be kept below the pump capacity while choosing orifice to insert in each position. The energy distribution from the orifice pattern is further complicated since the rotary path of all the orifices in the nozzle head pass through the center section. All orifices contribute to the stripping in the center of the path while only the outer most orifice contributes to the stripping at the edge of the nozzle. Additional orifices contribute to the stripping from the outer edge toward the center section. With all these parameters to configure and each parameter change affecting the others, a computer model was developed to track and coordinate these parameters. The computer simulation graphically indicates the cumulative affect from each parameter selected. The result from the proper choices in parameters is a well designed, highly efficient stripping system. A poorly chosen set of parameters will cause the nozzle to strip aggressively in some areas

  7. Tactile acuity charts: a reliable measure of spatial acuity.

    Science.gov (United States)

    Bruns, Patrick; Camargo, Carlos J; Campanella, Humberto; Esteve, Jaume; Dinse, Hubert R; Röder, Brigitte

    2014-01-01

    For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  8. The role of social closeness during tape stripping to facilitate skin barrier recovery: Preliminary findings.

    Science.gov (United States)

    Robinson, Hayley; Ravikulan, Abhimati; Nater, Urs M; Skoluda, Nadine; Jarrett, Paul; Broadbent, Elizabeth

    2017-07-01

    Social support is known to reduce the negative effects of stress on health, but there is mixed evidence for the effects of social support on wound healing. This study aimed to investigate whether undergoing a task designed to promote social closeness with a fellow participant and being paired with that person during a tape-stripping procedure could reduce stress and improve skin barrier recovery compared to going through tape stripping alone. Seventy-two healthy adults were randomized to either a social closeness condition where participants completed a relationship-building task and tape stripping in pairs or a control condition where they completed tape stripping alone. Skin barrier recovery was measured using transepidermal water loss. Salivary cortisol and alpha-amylase were collected at four time points as markers of the endocrine and autonomic stress response. Social closeness had a beneficial effect on skin barrier recovery compared to the control condition, t(54) = 2.86, p = .006, r = .36. Social closeness significantly reduced self-reported stress. The effects of the intervention on skin barrier recovery were moderated by self-reported stress reduction (p = .035). There were no significant differences in cortisol between groups, but alpha-amylase increased significantly more from baseline to after tape stripping in the control group compared to the intervention group. This is the first study to show that social closeness with a person going through a similar unfamiliar procedure can positively influence wound healing. Future research needs to replicate these findings in other wound types and in clinical settings. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. Memory-type control charts for monitoring the process dispersion

    NARCIS (Netherlands)

    Abbas, N.; Riaz, M.; Does, R.J.M.M.

    2014-01-01

    Control charts have been broadly used for monitoring the process mean and dispersion. Cumulative sum (CUSUM) and exponentially weighted moving average (EWMA) control charts are memory control charts as they utilize the past information in setting up the control structure. This makes CUSUM and

  10. National Forecast Charts

    Science.gov (United States)

    code. Press enter or select the go button to submit request Local forecast by "City, St" or Prediction Center on Twitter NCEP Quarterly Newsletter WPC Home Analyses and Forecasts National Forecast to all federal, state, and local government web resources and services. National Forecast Charts

  11. Customized versus population-based birth weight charts for the detection of neonatal growth and perinatal morbidity in a cross-sectional study of term neonates.

    Science.gov (United States)

    Carberry, Angela E; Raynes-Greenow, Camille H; Turner, Robin M; Jeffery, Heather E

    2013-10-15

    Customized birth weight charts that incorporate maternal characteristics are now being adopted into clinical practice. However, there is controversy surrounding the value of these charts in the prediction of growth and perinatal outcomes. The objective of this study was to assess the use of customized charts in predicting growth, defined by body fat percentage, and perinatal morbidity. A total of 581 term (≥37 weeks' gestation) neonates born in Sydney, Australia, in 2010 were included. Body fat percentage measurements were taken by using air displacement plethysmography. Objective composite measurements of perinatal morbidity were used to identify neonates who had poor outcomes; these data were extracted from medical records. The value of customized charts was assessed by calculating positive predictive values, negative predictive values, and odds ratios with 95% confidence intervals. Customized versus population-based charts did not improve the prediction of either low body fat percentage (59% vs. 66% positive predictive value and 87% vs. 89% negative predictive value, respectively) or high body fat percentage (48% vs. 53% positive predictive value and 90% vs. 89% negative predictive value, respectively). Customized charts were not better than population-based charts at predicting perinatal morbidity (for customized charts, odds ratio = 1.02, 95% confidence interval: 1.01, 1.04; for population-based charts, odds ratio = 1.03, 95% confidence interval: 1.01, 1.05) per percentile decrease in birth weight. Customized birth weight charts do not provide significant improvements over population-based charts in predicting neonatal growth and morbidity.

  12. A New Attribute Control Chart using Multiple Dependent State Repetitive Sampling

    KAUST Repository

    Aldosari, Mansour Sattam; Aslam, Muhammad; Jun, Chi-Hyuck

    2017-01-01

    In this manuscript, a new attribute control chart using multiple dependent state repetitive sampling is designed. The operational procedure and structure of the proposed control chart is given. The required measures to determine the average run length (ARL) for in-control and out-of-control processes are given. Tables of ARLs are reported for various control chart parameters. The proposed control chart is more sensitive in detecting a small shift in the process as compared to the existing attribute control charts. The simulation study shows the efficiency of the proposed chart over the existing charts. An example is given for the illustration purpose.

  13. A New Attribute Control Chart using Multiple Dependent State Repetitive Sampling

    KAUST Repository

    Aldosari, Mansour Sattam

    2017-03-25

    In this manuscript, a new attribute control chart using multiple dependent state repetitive sampling is designed. The operational procedure and structure of the proposed control chart is given. The required measures to determine the average run length (ARL) for in-control and out-of-control processes are given. Tables of ARLs are reported for various control chart parameters. The proposed control chart is more sensitive in detecting a small shift in the process as compared to the existing attribute control charts. The simulation study shows the efficiency of the proposed chart over the existing charts. An example is given for the illustration purpose.

  14. HydroHillChart – Pelton module. Software used to Calculate the Hill Chart of the Pelton Hydraulic Turbines

    OpenAIRE

    Dorian Nedelcu; Adelina Bostan; Florin Peris-Bendu

    2015-01-01

    The paper presents the HydroHillChart - Pelton module application, used to calculate the hill chart of the Pelton hydraulic turbine models, by processing the data measured on the stand. In addition, the tools offered by the application such as: interface, menu, input data, numerical and graphical results, etc. are described.

  15. The new silicon strip detectors for the CMS tracker upgrade

    International Nuclear Information System (INIS)

    Dragicevic, M.

    2010-01-01

    of the measurements. Design, implementation and production of sensors with integrated routing of signals from the sensor strip to the readout electronics. Electrical characterisation of the sensors and analysis of the measurements. Operational tests of the integrated sensors in a test beam experiment. Analysis of the data recorded during the test beam experiment. All the sensors and a part of the test structures were solely designed by me and implemented using tools which were created by myself as well. The manufacturing process for the sensors and test structures was implemented in close collaboration with the manufacturer. Furthermore, the necessary analysis of the data was supervised by me and the results are presented in this thesis for the first time. (author)

  16. Screening efficacy of a simplified logMAR chart

    Directory of Open Access Journals (Sweden)

    Naganathan Muthuramalingam

    2016-04-01

    Aim: This study evaluates the efficacy of a simplified logMAR chart, designed for VA testing over the conventional Snellen chart, in a school-based vision-screening programme. Methods: We designed a simplified logMAR chart by employing the principles of the Early Treatment Diabetic Retinopathy Study (ETDRS chart in terms of logarithmic letter size progression, inter-letter spacing, and inter-line spacing. Once the simplified logMAR chart was validated by students in the Elite school vision-screening programme, we set out to test the chart in 88 primary and middle schools in the Tiruporur block of Kancheepuram district in Tamil Nadu. One school teacher in each school was trained to screen a cross-sectional population of 10 354 primary and secondary school children (girls: 5488; boys: 4866 for VA deficits using a new, simplified logMAR algorithm. An experienced paediatric optometrist was recruited to validate the screening methods and technique used by the teachers to collect the data. Results: The optometrist screened a subset of 1300 school children from the total sample. The optometrist provided the professional insights needed to validate the clinical efficacy of the simplified logMAR algorithm and verified the reliability of the data collected by the teachers. The mean age of children sampled for validation was 8.6 years (range: 9–14 years. The sensitivity and the specificity of the simplified logMAR chart when compared to the standard logMAR chart were found to be 95% and 98%, respectively. Kappa value was 0.97. Sensitivity of the teachers’ screening was 66.63% (95% confidence interval [CI]: 52.73–77.02 and the specificity was 98.33% (95% CI: 97.49–98.95. Testing of VA was done under substandard illumination levels in 87% of the population. A total of 10 354 children were screened, 425 of whom were found to have some form of visual and/or ocular defect that was identified by the teacher or optometrist. Conclusion: The simplified logMAR testing algorithm

  17. Properties isotropy of magnesium alloy strip workpieces

    Directory of Open Access Journals (Sweden)

    Р. Кавалла

    2016-12-01

    Full Text Available The paper discusses the issue of obtaining high quality cast workpieces of magnesium alloys produced by strip roll-casting. Producing strips of magnesium alloys by combining the processes of casting and rolling when liquid melt is fed continuously to fast rolls is quite promising and economic. In the process of sheet stamping considerable losses of metal occur on festoons formed due to anisotropy of properties of foil workpiece, as defined by the macro- and microstructure and modes of rolling and annealing. The principal causes of anisotropic mechanical properties of metal strips produced by the combined casting and rolling technique are the character of distribution of intermetallic compounds in the strip, orientation of phases of metal defects and the residual tensions. One of the tasks in increasing the output of fit products during stamping operations consists in minimizing the amount of defects. To lower the level of anisotropy in mechanical properties various ways of treating the melt during casting are suggested. Designing the technology of producing strips of magnesium alloys opens a possibility of using them in automobile industry to manufacture light-weight body elements instead of those made of steel.

  18. Dynamic Characterizations of an 8-frame, Half-Strip, High-speed X-ray Microchannel Plate Imager

    International Nuclear Information System (INIS)

    Ken Moy; Ming Wu; Craig Kruschwitz; Aric Tibbits; Matt Griffin; Greg Rochau

    2008-01-01

    High-speed microchannel plate (MCP)-based imagers are critical detectors for x-ray diagnostics employed on Z-experiments at Sandia National Laboratories (SNL) to measure time-resolved x-ray spectra and to image dynamic hohlraums. A multiframe design using eight half strips in one imager permits recordings of radiation events in discrete temporal snapshots to yield a time-evolved movie. We present data using various facilities to characterize the performance of this design. These characterization studies include DC and pulsed-voltage biased measurements in both saturated and linear operational regimes using an intense, short-pulsed UV laser. Electrical probe measurements taken to characterize the shape of the HV pulse propagating across the strips help to corroborate the spatial gain dependence

  19. The making of Andersen’s liquefaction chart

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    Andersen’s chart (Andersen & Berre, 1999) is a graphical method of observing cyclic soil response. It allows observing soil response to various stress amplitudes that can lead to liquefaction, excess plastic deformation stabilizing soil response.The process of obtaining the original chart has been...

  20. 47 CFR 73.699 - TV engineering charts.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false TV engineering charts. 73.699 Section 73.699 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Television Broadcast Stations § 73.699 TV engineering charts. This section consists of the following Figures...

  1. Evaluation of silicon micro strip detectors with large read-out pitch

    International Nuclear Information System (INIS)

    Senyo, K.; Yamamura, K.; Tsuboyama, T.; Avrillon, S.; Asano, Y.; Bozek, A.; Natkaniec, Z.; Palka, H.; Rozanska, M.; Rybicki, K.

    1996-01-01

    For the development of the silicon micro-strip detector with the pitch of the readout strips as large as 250 μm on the ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips. (orig.)

  2. Chart of nuclides relating to neutron activation

    International Nuclear Information System (INIS)

    Okada, Minoru

    1981-09-01

    This chart is for frequent use in the prediction of the product species of neutron activation. The first edition of the chart has been made in 1976 after the repeated trial preparation. It has the following good points. (1) Any letter in chart is as large as one can read easily. [This condition has been obtained by the selection of items to be shown in chart. They are the name (the symbol of element, mass number, and half-life) of nuclide or of isomer, and the type of decay.]. (2) Decay product has been shown indirectly for branchings with two-step decay via short-lived daughter in an excited state. [This matter has been realized by use of the new mode of indication.] (3) Nuclides shown in chart are (a) naturally occurring nuclides and (b) nuclides formed from naturally occurring nuclides through one of the following reactions: (n, γ), (n, n'), (n, p), (n, α), (n, 2n), (n, pn), (n, 3n), (n, αn), (n, t), (n, 3 He), (n, 2p), and (n, γ)(n, γ). In the revision of the first edition, some modes of indication have become a little simpler, and the isomers of shorter half-lives (0.1 - 1 μs) have been added. (author)

  3. Control chart applications in healthcare: a literature review

    Science.gov (United States)

    Suman, Gaurav; Prajapati, DeoRaj

    2018-05-01

    The concept of Statistical process control (SPC) was given by the physicist Walter Shewhart in order to improve the industrial manufacturing. The SPC was firstly applied in laboratory and after then shifted to patient level in hospitals. As there is more involvement of human in healthcare, the chances of errors are also more. SPC i.e., control chart can help in determining the source of errors by identifying the special and common causes of variations. This paper presents the review of literature on the application of SPC and control chart in healthcare sector. Forty articles are selected out of 142 potentially relevant searched studies. Selected studies are categorised into eight departments. Literature survey shows that most of work on control chart applications in healthcare is carried out in Surgery, Emergency and Epidemiology departments. US, UK and Australia are the main customers where maximum amount of work was done. The US is the country where control chart in healthcare sector have been used at regular interval. This shows the gap of deploying control chart in different departments and different countries as well. The CUSUM and EWMA chart came into picture in healthcare sector after 2008 and are used at regular interval.

  4. Nuclear industry chart

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    As part of a survey on Switzerland a pull-out organisation chart is presented of the nuclear industry showing Swiss government bodies and industrial concerns. Their interests, connections with each other and their associations with international and other national organizations and firms are indicated. (U.K.)

  5. Micro-strip sensors based on CVD diamond

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D' Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D. E-mail: dirk.meier@cern.ch; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M

    2000-10-11

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  6. Micro-strip sensors based on CVD Diamond

    CERN Document Server

    Adam, W; Bergonzo, P; Bertuccio, G; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; D'Angelo, P; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Hallewell, G D; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Koeth, T W; Krammer, Manfred; Lo Giudice, A; Lü, R; MacLynne, L; Manfredotti, C; Meier, D; Mishina, M; Moroni, L; Oh, A; Pan, L S; Pernicka, Manfred; Peitz, A; Perera, L P; Pirollo, S; Procario, M; Riester, J L; Roe, S; Rousseau, L; Rudge, A; Russ, J; Sala, S; Sampietro, M; Schnetzer, S R; Sciortino, S; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R J; Trischuk, W; Tromson, D; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; Wetstein, M; White, C; Zeuner, W; Zoeller, M M

    2000-01-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  7. Micro-strip sensors based on CVD diamond

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.

    2000-01-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation

  8. Micro-strip sensors based on CVD diamond

    Science.gov (United States)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; RD42 Collaboration

    2000-10-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  9. Membrane air stripping utilizing a plate and frame configuration

    International Nuclear Information System (INIS)

    Boswell, S.T.

    1991-01-01

    Membrane air stripping has recently been proposed as a possible method to remove volatile organic chemicals (VOCs) and radon from drinking water supplies. Current and anticipated regulatory requirements, driven by health consequences, make the removal of these contaminants mandatory. This work examines the use of plate and frame membrane air stripping for the removal of VOCs and radon from a water supply. The theoretical basis of membrane air stripping and a literature review are included. The advantages of membrane air stripping versus other methods of removal, as well as the advantages of a plate and frame configuration versus a hollow fiber configuration for membrane air stripping are discussed. Multiple regression/correlation techniques are used to model mass transfer coefficients and fluid resistances. An economic evaluation is performed using the developed models. The costs of comparable membrane and packed tower air stripping systems are 4.86 cents per thousand gallons versus 4.36 cents per thousand gallons, respectively. This work indicates that plate and frame membrane air stripping may, in fact, prove to be an economical alternative to packed tower aeration and carbon adsorption for the removal of VOCs and radon

  10. Examination of Routine Use of Prenatal Weight Gain Charts as a Communication Tool for Providers.

    Science.gov (United States)

    Aguilera, Marijo; Sidebottom, Abbey C; McCool, Brigitte R

    2017-10-01

    Objectives In 2009 the IOM revised prenatal weight gain guidelines. The primary purpose of this pilot study was to assess if provider education and use of prenatal weight gain charts to track weight gain and counsel patients was associated with better patient and provider knowledge and communication about the guidelines. Methods A prospective non-randomized study conducted in four OB practices (two control, two intervention). Data sources included provider surveys (n = 16 intervention, 21 control), patient surveys (n = 332), and medical records. Intervention clinics received provider education on the IOM guidelines and used patient education materials and prenatal weight gain charts to track weight gain and as a counseling tool. Comparison clinics received no education and did not use the charts or patient education information. Results More patients at intervention clinics (92.3%) reported that a provider gave them advice about weight gain, compared to patients from comparison clinics (66.4%) (p gain (83.1 vs. 64.3%, p = 0.007). Intervention clinic patients were more likely to have knowledge of the guidelines indicated by 72.3% reporting a target weight gain amount within the guidelines versus 50.4% of comparison patients (p gain charts resulted in higher patient reported communication about weight gain from their provider, higher patient satisfaction with those discussions, and better knowledge of the appropriate target weight gain goals.

  11. Advection endash diffusion past a strip. II. Oblique incidence

    International Nuclear Information System (INIS)

    Knessl, C.; Keller, J.B.

    1997-01-01

    Advection and diffusion of particles past an impenetrable strip is considered when the strip is oblique to the advection or drift velocity. The particle concentration p(x,y) is determined asymptotically for large values of vL/D, where v is the drift velocity, D is the diffusion coefficient, and 2L is the width of the strip. The results complement those of Part I, which treated a strip normal to the drift velocity. copyright 1997 American Institute of Physics

  12. Tactile acuity charts: a reliable measure of spatial acuity.

    Directory of Open Access Journals (Sweden)

    Patrick Bruns

    Full Text Available For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  13. Stripping of uranium from Dehpa/kerosene solvents by different aqueous media

    International Nuclear Information System (INIS)

    Khorfan, S.; Stas, J.; Kassem, M.

    1998-01-01

    Stripping uranium from Dehpa/kerosene solvent is a crucial step in the recovery of uranium. Stripping was studied using different stripping media mainly ammonium carbonate, phosphoric acid, sulfuric acid, hydrochloric acid and nitric acid. Stripping was measured at different operating conditions such as aqueous concentrations, temperatures, and Dehpa/kerosene concentrations. The results obtained showed that stripping by acid media increases with the acid concentration and follows the order: HF > H 3 PO 4 > H 2 SO 4 > HCl > HNO 3 . To achieve higher stripping by phosphoric acid it was found necessary to increase the temperature to 50 deg C, the acid concentration to 5 mol/l and to reduce the uranium to U 4+ . Stripping by basic media was found to increase with increasing concentration of the stripping media and to follow the order: Na 2 CO 3 > (NH 4 ) 2 CO 3 > NH 4 HCO 3 . Stripping by ammonium carbonate was found to increase with temperature and carbonate concentration. The stripping was optimized at 0.5 mol/l carbonate concentration and at a temperature of 50 deg C. Stripping was decreased by increasing concentration of Dehpa in kerosene and was depressed more by adding the synergant Topo to the Dehpa solvent especially at 1/4 mol/mol ratio. (author)

  14. SU-D-BRD-01: An Automated Physics Weekly Chart Checking System Supporting ARIA

    Energy Technology Data Exchange (ETDEWEB)

    Chang, X; Yang, D [Washington University in St Louis, St Louis, MO (United States)

    2015-06-15

    Purpose: A software tool was developed in this study to perform automatic weekly physics chart check on the patient data in ARIA. The tool accesses the electronic patient data directly from ARIA server and checks the accuracy of treatment deliveries, and generates reports which summarize the delivery history and highlight the errors. Methods: The tool has four modules. 1) The database interface is designed to directly access treatment delivery data from the ARIA database before reorganizing the data into the patient chart tree (PCT). 2) PCT is a core data structure designed to store and organize the data in logical hierarchies, and to be passed among functions. 3) The treatment data check module analyzes the organized data in PCT and stores the checking results into PCT. 4) Report generation module generates reports containing the treatment delivery summary, chart checking results and plots of daily treatment setup parameters (couch table positions, shifts of image guidance). The errors that are found by the tool are highlighted with colors. Results: The weekly check tool has been implemented in MATLAB and clinically tested at two major cancer centers. Javascript, cascading style sheets (CSS) and dynamic HTML were employed to create the user-interactive reports. It takes 0.06 second to search the delivery records of one beam with PCT and compare the delivery records with beam plan. The reports, saved in the HTML files on shared network folder, can be accessed by web browser on computers and mobile devices. Conclusion: The presented weekly check tool is useful to check the electronic patient treatment data in Varian ARIA system. It could be more efficient and reliable than the manually check by physicists. The work was partially supported by a research grant from Varian Medical System.

  15. SU-D-BRD-01: An Automated Physics Weekly Chart Checking System Supporting ARIA

    International Nuclear Information System (INIS)

    Chang, X; Yang, D

    2015-01-01

    Purpose: A software tool was developed in this study to perform automatic weekly physics chart check on the patient data in ARIA. The tool accesses the electronic patient data directly from ARIA server and checks the accuracy of treatment deliveries, and generates reports which summarize the delivery history and highlight the errors. Methods: The tool has four modules. 1) The database interface is designed to directly access treatment delivery data from the ARIA database before reorganizing the data into the patient chart tree (PCT). 2) PCT is a core data structure designed to store and organize the data in logical hierarchies, and to be passed among functions. 3) The treatment data check module analyzes the organized data in PCT and stores the checking results into PCT. 4) Report generation module generates reports containing the treatment delivery summary, chart checking results and plots of daily treatment setup parameters (couch table positions, shifts of image guidance). The errors that are found by the tool are highlighted with colors. Results: The weekly check tool has been implemented in MATLAB and clinically tested at two major cancer centers. Javascript, cascading style sheets (CSS) and dynamic HTML were employed to create the user-interactive reports. It takes 0.06 second to search the delivery records of one beam with PCT and compare the delivery records with beam plan. The reports, saved in the HTML files on shared network folder, can be accessed by web browser on computers and mobile devices. Conclusion: The presented weekly check tool is useful to check the electronic patient treatment data in Varian ARIA system. It could be more efficient and reliable than the manually check by physicists. The work was partially supported by a research grant from Varian Medical System

  16. Run charts revisited: a simulation study of run chart rules for detection of non-random variation in health care processes.

    Science.gov (United States)

    Anhøj, Jacob; Olesen, Anne Vingaard

    2014-01-01

    A run chart is a line graph of a measure plotted over time with the median as a horizontal line. The main purpose of the run chart is to identify process improvement or degradation, which may be detected by statistical tests for non-random patterns in the data sequence. We studied the sensitivity to shifts and linear drifts in simulated processes using the shift, crossings and trend rules for detecting non-random variation in run charts. The shift and crossings rules are effective in detecting shifts and drifts in process centre over time while keeping the false signal rate constant around 5% and independent of the number of data points in the chart. The trend rule is virtually useless for detection of linear drift over time, the purpose it was intended for.

  17. HydroHillChart – Pelton module. Software used to Calculate the Hill Chart of the Pelton Hydraulic Turbines

    Directory of Open Access Journals (Sweden)

    Dorian Nedelcu

    2015-07-01

    Full Text Available The paper presents the HydroHillChart - Pelton module application, used to calculate the hill chart of the Pelton hydraulic turbine models, by processing the data measured on the stand. In addition, the tools offered by the application such as: interface, menu, input data, numerical and graphical results, etc. are described.

  18. Stage- vs. Channel-strip Metaphor

    DEFF Research Database (Denmark)

    Gelineck, Steven; Korsgaard, Dannie Michael; Büchert, Morten

    2015-01-01

    This study compares the stage metaphor and the channel strip metaphor in terms of performance. Traditionally, music mixing consoles employ a channels strip control metaphor for adjusting parameters such as volume and panning of each track. An alternative control metaphor, the so-called stage meta...... is surprisingly similar and thus we are not able to detect any significant difference in performance between the two interfaces. Qualitative data however, suggests that the stage metaphor is largely favoured for its intuitive interaction - confirming earlier studies....

  19. Study of inter-strip gap effects and efficiency for full energy detection of double sided silicon strip detectors

    International Nuclear Information System (INIS)

    Fisichella, M.; Forneris, J.; Grassi, L.

    2015-01-01

    We performed a characterization of Double Sided Silicon Strip Detectors (DSSSD) with the aim to carry out a systematic study of the inter-strip effects on the energy measurement of charged particles. The dependence of the DSSSD response on ion, energy and applied bias has been investigated. (author)

  20. 46 CFR 232.3 - Chart of accounts.

    Science.gov (United States)

    2010-10-01

    ... stated in any revision to generally accepted accounting principles, the meaning of the latter shall... UNIFORM FINANCIAL REPORTING REQUIREMENTS § 232.3 Chart of accounts. (a) Purpose of accounts. A contractor shall use this chart of accounts as a guide for preparing the financial statements and for other...

  1. 33 CFR 164.33 - Charts and publications.

    Science.gov (United States)

    2010-07-01

    ...) PORTS AND WATERWAYS SAFETY NAVIGATION SAFETY REGULATIONS § 164.33 Charts and publications. (a) Each vessel must have the following: (1) Marine charts of the area to be transited, published by the National... tables published by private entities using data provided by the National Ocean Service. (ii) Tidal...

  2. 21 CFR 886.1150 - Visual acuity chart.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Visual acuity chart. 886.1150 Section 886.1150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1150 Visual acuity chart. (a) Identification...

  3. Robust Control Charts for Time Series Data

    NARCIS (Netherlands)

    Croux, C.; Gelper, S.; Mahieu, K.

    2010-01-01

    This article presents a control chart for time series data, based on the one-step- ahead forecast errors of the Holt-Winters forecasting method. We use robust techniques to prevent that outliers affect the estimation of the control limits of the chart. Moreover, robustness is important to maintain

  4. 4 GHz ionospheric scintillations observed at Taipei

    International Nuclear Information System (INIS)

    Huang, Y.N.; Jeng, B.S.

    1978-01-01

    In a study of ionospheric scintillations 3950 MHz beacon signals from geostationary communication satellites Intelsat-IV-F8 and Intelsat-IV-F1 were recorded on a strip chart and magnetic tape at the Taipei Earth Station. While the strip charts were used to monitor the occurrence of the scintillation, the magnetic tape output was digitized and processed by a computerized system to yield a detailed analysis of scintillation events. It was found that diurnal variations were similar to the diurnal patterns of sporadic E at greater than 5 MHz and VHF band ionospheric scintillations during daytime as reported by Huang (1978). Eight typical scintillation events were selected for the calculation of the scintillation index, S4, and other parameters. The mean S4 index for the 8 events was found to be 0.15. Numerical and graphic results are presented for the cumulative amplitude distributions, message reliability, autocorrelation functions and power spectra

  5. Stripping of uranium from Dehpa/Kerosene solvents by different aqueous media

    International Nuclear Information System (INIS)

    Khorfan, S.; Stas, J.; Kassem, M.

    2000-01-01

    Stripping uranium from Dehpa/kerosene solvent is a crucial step in the recovery of uranium. Stripping was studied using different stripping media mainly ammonium carbonate, phosphoric acid, sulfuric acid, hydrochloric acid and nitric acid. Stripping was measured at different operating conditions such as aqueous concentrations, temperatures, and Dehpa/kerosene concentrations. The results obtained showed that stripping by acid media increases with the acid concentration and follows the order: HF > H sub 3 Po sub 4 > H sub 2 S O sub 4 > HCl > HNO sub 3. To achieve higher stripping by phosphoric acid it was found necessary to increase the temperature to 50 deg C, the acid concentration to 5 mol/l and to reduce the uranium to U sup 4 sup +. Stripping by basic media was found to increase with increasing concentration of the stripping media and to follow the order: Na sub 2 CO sub 3 > (NH sub 4) sub 2 CO sub 3 > NH sub 4 HCO sub 3. Stripping by ammonium carbonate was found to increase with temperature and carbonate concentration. The stripping was optimized at 0.5 mol/l carbonate concentration and at a temperature of 50 deg C. Stripping was decreased by increasing concentration of Dehpa in kerosene and was depressed more by adding the synergant TOPO to the Dehpa solvent especially at 1/4 mol/mol ratio. (author)

  6. [Growth charts: Impact on the prevalence of nutritional disorders].

    Science.gov (United States)

    Polo Martín, P; Abellan, J J; Nájar Godoy, M I; Álvarez de Laviada Mulero, T

    2015-05-01

    The references used to assess child growth in Spain are the graphs of the Orbegozo Foundation and the charts of the World Health Organization (WHO). The objective of this study is to analyze the differences between the two charts for weight, height and body mass index, and assess their relevance to identify growth or nutritional problems. The values of the extreme percentiles of height, weight and body mass index for each sex from 0 to 10 years in both charts are compared. For each value Absolute differences and Z scores are calculated for each value. To evaluate the impact on the prevalence of the various nutritional or growth disorders the location of the value of the respective percentiles of in each of the charts were assessed. Significant differences were observed between the 3th percentile of height and weight, 97th of weight, and 85th and 97th of body mass index. Marked differences were observed for the extreme values of body mass index. During the first years, the Orbegozo charts overestimate the prevalence of malnutrition (between 2% and 19% depending on age and sex) compared to the WHO charts. In subsequent ages Orbegozo underestimates WHO between 0.7% and 2.89%. Orbegozo underestimates the prevalence of overweight (between 2.5% and 14.8%) compared to the WHO charts. The 97th percentile of Body mass index in the Orbegozo charts corresponds in most cases with WHO percentiles above 99.99%. The two charts analyzed have significant differences from a clinical and the public health point of view, in the estimation of overweight/obesity and malnutrition. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  7. Adherence to the Australian National Inpatient Medication Chart: the efficacy of a uniform national drug chart on improving prescription error.

    Science.gov (United States)

    Atik, Alp

    2013-10-01

    In 2006, the National Inpatient Medication Chart (NIMC) was introduced as a uniform medication chart in Australian public hospitals with the aim of reducing prescription error. The rate of regular medication prescription error in the NIMC was assessed. Data was collected using the NIMC Audit Tool and analyzed with respect to causes of error per medication prescription and per medication chart. The following prescription requirements were assessed: date, generic drug name, route of administration, dose, frequency, administration time, indication, signature, name and contact details. A total of 1877 medication prescriptions were reviewed. 1653 prescriptions (88.07%) had no contact number, 1630 (86.84%) did not have an indication, 1230 and 675 (35.96%) used a drug's trade name. Within 261 medication charts, all had at least one entry, which did not include an indication, 258 (98.85%) had at least one entry, which did not have a contact number and 200 (76.63%) had at least one entry, which used a trade name. The introduction of a uniform national medication chart is a positive step, but more needs to be done to address the root causes of prescription error. © 2012 John Wiley & Sons Ltd.

  8. Strip defect recognition in electrical tests of silicon microstrip sensors

    Energy Technology Data Exchange (ETDEWEB)

    Valentan, Manfred, E-mail: valentan@mpp.mpg.de

    2017-02-11

    This contribution describes the measurement procedure and data analysis of AC-coupled double-sided silicon microstrip sensors with polysilicon resistor biasing. The most thorough test of a strip sensor is an electrical measurement of all strips of the sensor; the measured observables include e.g. the strip's current and the coupling capacitance. These measurements are performed to find defective strips, e.g. broken capacitors (pinholes) or implant shorts between two adjacent strips. When a strip has a defect, its observables will show a deviation from the “typical value”. To recognize and quantify certain defects, it is necessary to determine these typical values, i.e. the values the observables would have without the defect. As a novel approach, local least-median-of-squares linear fits are applied to determine these “would-be” values of the observables. A least-median-of-squares fit is robust against outliers, i.e. it ignores the observable values of defective strips. Knowing the typical values allows to recognize, distinguish and quantify a whole range of strip defects. This contribution explains how the various defects appear in the data and in which order the defects can be recognized. The method has been used to find strip defects on 30 double-sided trapezoidal microstrip sensors for the Belle II Silicon Vertex Detector, which have been measured at the Institute of High Energy Physics, Vienna (Austria).

  9. 32 CFR 728.93 - Chart of adjuncts.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Chart of adjuncts. 728.93 Section 728.93 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY PERSONNEL MEDICAL AND DENTAL CARE FOR ELIGIBLE PERSONS AT NAVY MEDICAL DEPARTMENT FACILITIES Adjuncts to Medical Care § 728.93 Chart of...

  10. Robust control charts in statistical process control

    NARCIS (Netherlands)

    Nazir, H.Z.

    2014-01-01

    The presence of outliers and contaminations in the output of the process highly affects the performance of the design structures of commonly used control charts and hence makes them of less practical use. One of the solutions to deal with this problem is to use control charts which are robust

  11. Strip type radiation detector and method of making same

    International Nuclear Information System (INIS)

    Jantsch, O.; Feigt, I.; Willig, W.R.

    1976-01-01

    An improved strip detector and a method for making such a detector in which a high resistivity N conduction semiconductor body has electrode strips formed thereon by diffusion is described. The strips are formed so as to be covered by an oxide layer at the surface point of the PN junction and in which the opposite side of the semiconductor body then has a substantial amount of material etched away to form a thin semiconductor upon which strip electrodes which are perpendicular to the electrodes on the first side are then placed

  12. Improvement of WWW chart of the nuclides interface

    International Nuclear Information System (INIS)

    Okamoto, Tsutomu; Minato, Futoshi; Iwamoto, Osamu; Koura, Hiroyuki

    2016-03-01

    The booklet 'chart of the nuclides' is issued every 4 years since 1976 from Nuclear Data Center, Japan Atomic Energy Agency. The chart of the nuclides for WWW (World Wide Web) was developed in 1999 in order to be available from the Internet browser. The Internet connection speeds, browser functions and JavaScript libraries has, however, progressed at present compared with the Internet technology in those days. In connection with the release of the 2014 edition of the chart of the nuclides, the interface of the WWW chart of the nuclides has been improved by introducing new Internet technologies aiming at enhancing convenience on accessibilities via browsers. We introduced a scrolling screen that would make capabilities of easy screen movement on a map with the addition of the drag scrolling function. Considering smart phone access, the light-weight edition which introduced automatic switch was prepared. The new system results in reduction in access time and usefulness in mobile environment. The method of making figures of the chart was reconsidered due to addition of new decay schemes to the 2014 edition. SVG (Scalable Vector Graphics) was adopted so as to make figures easily. It is concluded that the accessibilities of WWW chart of the nuclides are substantially improved from the previous version by introducing the new technologies. (author)

  13. Stripping voltammetry in environmental and food analysis.

    Science.gov (United States)

    Brainina, K Z; Malakhova, N A; Stojko, N Y

    2000-10-01

    The review covers over 230 papers published mostly in the last 5 years. The goal of the review is to attract the attention of researchers and users to stripping voltammetry in particular, its application in environmental monitoring and analysis of foodstuffs. The sensors employed are impregnated graphite, carbon paste, thick film carbon/graphite and thin film metallic electrodes modified in-situ or beforehand. Hanging mercury drop electrodes and mercury coated glassy carbon electrodes are also mentioned. Strip and long-lived sensors for portable instruments and flow through systems are discussed as devices for future development and application of stripping voltammetry.

  14. Dental Charting. Learning Activities, Unit Tests, Progress Chart, and Work Sheet.

    Science.gov (United States)

    Texas Univ., Austin. Center for Occupational Curriculum Development.

    These materials are part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. These student materials, designed to be used with the Dental Charting Student Manual, consist of learning activities, unit…

  15. Weldability charts for constructional steels

    International Nuclear Information System (INIS)

    Ion, J C; Ashby, M F

    2012-01-01

    The weldability of materials is still a poorly understood concept; a quantitative assessment remains elusive. The variables associated with welding are reduced here into two groups - processing parameters and material properties - from which two characteristic indices are defined and used as the basis of weldability charts. For the case of constructional steels, a carbon equivalent characterises both heat affected zone hardenability and the maximum hardness developed after solid state phase transformations. The welding process is characterised by its energy input. A mathematical model is used to establish relationships between the indices, which are displayed on charts as contours of microstructure and hardness.

  16. CDC Child Growth Charts

    Data.gov (United States)

    U.S. Department of Health & Human Services — CDC child growth charts consist of a series of percentile curves that illustrate the distribution of selected body measurements in U.S. children. Pediatric growth...

  17. Visualizing a Procedure with Nassi-Schneiderman Charts.

    Science.gov (United States)

    Weiss, Edmond H.

    1990-01-01

    Argues that Nassi-Schneiderman (NS) charts, when used to diagram human procedures, can eliminate prose ambiguities. Asserts that these devices provide most of the advantages of decision tables and trees. Suggests using NS charts in testing the logic and completeness of traditional procedures, or even in place of many traditional publications. (SG)

  18. Comparison of customised growth charts v. standard population

    African Journals Online (AJOL)

    pregnant diabetic population using population-based growth charts and customised growth charts. Methods. ... Of the patients, 44 had type 1, 66 type 2 and 173 gestational diabetes. The growth of .... with diabetic ketoacidosis, of whom one.

  19. Finding charts for southern IRAS galaxies

    International Nuclear Information System (INIS)

    Sutherland, W.J.; Maddox, S.J.; Saunders, W.

    1991-01-01

    Using the APM Galaxy Survey, we have generated a collection of finding charts for 4614 sources with non-stellar colours in the IRAS Faint Source Catalogue south of δ= -17.5 o . Over 90 per cent of the sources are reliably identified with an optical object, and we provide 1-arcsec positions and B J magnitudes for these. We will provide paper copies of the charts on request, at a small charge to cover photocopying costs. (author)

  20. The European chart of territorial planning

    International Nuclear Information System (INIS)

    1998-01-01

    In this chapter the European chart of territorial planning is included. This European chart contains next chapters: Introduction; The mission of the territorial planning; The basic aims; Realization of aims of the territorial planning; The confirmation of the European co-operation. In the Appendix the Specific aims: (1) The village territory; (2) The urban territory; (3) The boundary territory; (4) The mountain territory; (5) The structurally weak territory; (6) The decaying territory; (7) The coastal territories and islands

  1. Audit of Medical Records of Shahid Madani Hospital

    Directory of Open Access Journals (Sweden)

    Mohammad farough-khosravi

    2016-12-01

    Full Text Available Background and Objectives: Evaluation of the quality of services and provided cares through comparing them with existing standards in order to identify and prioritize problems and trying to fix them are important steps in the audit of clinical functions. This study aimed to improve the quality of performance of medical records registrations about patients admitted to hospital Shahid Madani and deals with the audit of records listed them. Material and Methods: To perform this study, data were collected using researcher checklist. Target data of 30 medical records were gathered. We used software package of Mini Tab and SPSS to develop process statistical control charts and for statistical analysis of data, respectively. Results: By plotting control charts, we determined three specific reasons in the ADMISSION AND DISCHARGE SUMMARY SHEET, four specific reasons in the SUMMARY SHEET, and three specific reasons in CONSULTATION REQUEST SHEET. The lack of the standard form (on-delivered copies of a summary form “with 90%”, lack of the main form in patient's clinical record “with 83.3%”, lack of the patient's procedure “with 73.3%”are ranked as the most defects in SUMMARY SHEET. In the CONSULTATION REQUEST SHEET, failure to comply with doctor's stamp and signature standard with “20%” has highest percentage of defects. In the ADMISSION AND DISCHARGE SUMMARY SHEET nonconformity of standard records, patient's duration of stay “100%”, coding of diseases based on ICD"100%", recording of patient number based on signs and symptoms "93.3%", usingthe abbreviations to record the recognitions "93.3%" have highest percentage of defects respectively. Conclusion: Based on the results of this study and noting that studied standards of process statistical control charts are in the range of control, the quality of standards and the documentations of  the records

  2. Collisional stripping of planetary crusts

    Science.gov (United States)

    Carter, Philip J.; Leinhardt, Zoë M.; Elliott, Tim; Stewart, Sarah T.; Walter, Michael J.

    2018-02-01

    Geochemical studies of planetary accretion and evolution have invoked various degrees of collisional erosion to explain differences in bulk composition between planets and chondrites. Here we undertake a full, dynamical evaluation of 'crustal stripping' during accretion and its key geochemical consequences. Crusts are expected to contain a significant fraction of planetary budgets of incompatible elements, which include the major heat producing nuclides. We present smoothed particle hydrodynamics simulations of collisions between differentiated rocky planetesimals and planetary embryos. We find that the crust is preferentially lost relative to the mantle during impacts, and we have developed a scaling law based on these simulations that approximates the mass of crust that remains in the largest remnant. Using this scaling law and a recent set of N-body simulations of terrestrial planet formation, we have estimated the maximum effect of crustal stripping on incompatible element abundances during the accretion of planetary embryos. We find that on average approximately one third of the initial crust is stripped from embryos as they accrete, which leads to a reduction of ∼20% in the budgets of the heat producing elements if the stripped crust does not reaccrete. Erosion of crusts can lead to non-chondritic ratios of incompatible elements, but the magnitude of this effect depends sensitively on the details of the crust-forming melting process on the planetesimals. The Lu/Hf system is fractionated for a wide range of crustal formation scenarios. Using eucrites (the products of planetesimal silicate melting, thought to represent the crust of Vesta) as a guide to the Lu/Hf of planetesimal crust partially lost during accretion, we predict the Earth could evolve to a superchondritic 176Hf/177Hf (3-5 parts per ten thousand) at present day. Such values are in keeping with compositional estimates of the bulk Earth. Stripping of planetary crusts during accretion can lead to

  3. Statistical process control charts for monitoring military injuries.

    Science.gov (United States)

    Schuh, Anna; Canham-Chervak, Michelle; Jones, Bruce H

    2017-12-01

    An essential aspect of an injury prevention process is surveillance, which quantifies and documents injury rates in populations of interest and enables monitoring of injury frequencies, rates and trends. To drive progress towards injury reduction goals, additional tools are needed. Statistical process control charts, a methodology that has not been previously applied to Army injury monitoring, capitalise on existing medical surveillance data to provide information to leadership about injury trends necessary for prevention planning and evaluation. Statistical process control Shewhart u-charts were created for 49 US Army installations using quarterly injury medical encounter rates, 2007-2015, for active duty soldiers obtained from the Defense Medical Surveillance System. Injuries were defined according to established military injury surveillance recommendations. Charts display control limits three standard deviations (SDs) above and below an installation-specific historical average rate determined using 28 data points, 2007-2013. Charts are available in Army strategic management dashboards. From 2007 to 2015, Army injury rates ranged from 1254 to 1494 unique injuries per 1000 person-years. Installation injury rates ranged from 610 to 2312 injuries per 1000 person-years. Control charts identified four installations with injury rates exceeding the upper control limits at least once during 2014-2015, rates at three installations exceeded the lower control limit at least once and 42 installations had rates that fluctuated around the historical mean. Control charts can be used to drive progress towards injury reduction goals by indicating statistically significant increases and decreases in injury rates. Future applications to military subpopulations, other health outcome metrics and chart enhancements are suggested. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. An Exponentially Weighted Moving Average Control Chart for Bernoulli Data

    DEFF Research Database (Denmark)

    Spliid, Henrik

    2010-01-01

    of the transformation is given and its limit for small values of p is derived. Control of high yield processes is discussed and the chart is shown to perform very well in comparison with both the most common alternative EWMA chart and the CUSUM chart. The construction and the use of the proposed EWMA chart......We consider a production process in which units are produced in a sequential manner. The units can, for example, be manufactured items or services, provided to clients. Each unit produced can be a failure with probability p or a success (non-failure) with probability (1-p). A novel exponentially...... weighted moving average (EWMA) control chart intended for surveillance of the probability of failure, p, is described. The chart is based on counting the number of non-failures produced between failures in combination with a variance-stabilizing transformation. The distribution function...

  5. Great Lakes Ice Charts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Charts show ice extent and concentration three times weekly during the ice season, for all lakes except Ontario, from the 1973/74 ice season through the 2001/2002...

  6. MRO CRISM MULTISPECTRAL REDUCED DATA RECORD V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset contains CRISM Multispectral Reduced Data Records (MRDRs). MRDRs are organized into 30 subdirectories named by the Mars Chart containing the MRDR, e.g....

  7. New Concept of Cultivation Using Limited Strip-Tillage with Strip Shallow Irrigation

    Directory of Open Access Journals (Sweden)

    Yazid Ismi Intara

    2014-04-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE Dry land is one of land resources which potentially used for food crop cultivation, especially in the areas which have light to medium technical obstacles. The development of technology to improve soil quality in marginal lands to be productive lands is still widely open for agricultural development in Indonesia. Rooting medium quality can be improved by changing soil tillage method and observing the proper crop irrigation technology. It can be the solution for crop cultivation in clay loam soil. This study aimed to obtain water movement model in a minimally-tilled clay soil with strip shallow irrigation. The concept is limited soil-tillage with strip shallow irrigation method, water supply technique, and crop water requirement. Method used in this study includes developing water movement model (software development in a minimally-tilled clay soil with subsurface irrigation. In the final stages, research also conducted water movement analysis testing apparatus in the laboratory, field validation of the subsurface irrigation performance, and cultivation technique testing to chili pepper growth (Capsicum annuumL.. The development of water movement simulation on a limited strip-tillage with subsurface irrigation uses the concept to quantify the amount of water in the soil. The analysis of movement pattern was demonstrated on contour patterns. It showed that the wetting process can reach depth zone – 5 cm to the rooting zone. It was an important discovery on the development of minimum stripe tillage soil with subsurface irrigation. Specifically, it can be concluded that: the result of fitting by eyes to diffusivity graphic and water content obtained the required parameter values for soil physical properties. It was then simulated on horizontal water movement model on a minimum strip-tillage with strip shallow irrigation /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso

  8. Whole plantar nerve conduction study with disposable strip electrodes.

    Science.gov (United States)

    Hemmi, Shoji; Kurokawa, Katsumi; Nagai, Taiji; Okamoto, Toshio; Murakami, Tatsufumi; Sunada, Yoshihide

    2016-02-01

    A new method to evaluate whole plantar nerve conduction with disposable strip electrodes (DSEs) is described. Whole plantar compound nerve action potentials (CNAPs) were recorded at the ankle. DSEs were attached to the sole for simultaneous stimulation of medial and lateral plantar nerves. We also conducted medial plantar nerve conduction studies using an established method and compared the findings. Whole plantar CNAPs were recorded bilaterally from 32 healthy volunteers. Mean baseline to peak amplitude for CNAPs was 26.9 ± 11.8 μV, and mean maximum conduction velocity was 65.8 ± 8.3 m/s. The mean amplitude of CNAPs obtained by our method was 58.2% higher than that of CNAPs obtained by the Saeed method (26.9 μV vs. 17.0 μV; P < 0.0001). The higher mean amplitude of whole plantar CNAPs obtained by our method suggests that it enables CNAPs to be obtained easily, even in elderly people. © 2015 Wiley Periodicals, Inc.

  9. Chesapeake Highway Advisories Routing Traffic, Chart, Business Plan

    Science.gov (United States)

    1996-10-01

    THE BUSINESS PLAN IS ORGANIZED INTO FOUR MAJOR SECTIONS. THE FIRST SECTION IS INTRODUCTORY IN NATURE AND PROVIDES BACKGROUND INFORMATION ON ITS AND THE CHART PROGRAM IN MARYLAND. IT INCLUDES THE CHART MISSION, GOALS AND OBJECTIVES, AS WELL AS OVERVIE...

  10. Frictional interactions in forming processes: New studies with transparent sapphire strip-drawing dies

    Science.gov (United States)

    Rao, R. S.; Lu, C. Y.; Wright, P. K.; Devenpeck, M. L.; Richmond, O.; Appleby, E. J.

    1982-05-01

    This research is concerned with the frictional interactions at the toolwork interfaces in the machining and strip-drawing processes. A novel feature is that transparent sapphire (single crystal Al2O3) is being used as the tool and die material. This allows the tribological features of the interface to be directly observed and recorded on movie-film. These qualitative studies provide information on the role of lubricants. In addition, techniques are being developed to quantify the velocity gradient along the interface. For example, in the drawing work it has been found that tracer markings (e.g. dye-spots), applied to the undrawn strip, remain intact during drawing and can be tracked along the sapphire/strip interface. Such data will be used as input to a finite-element, elasto-plastic-workhardening model of the deformation process. The latter can compute strip deformation characteristics, drawing forces and local coefficients of friction at the interface. Introductory results will be presented in this paper, obtained from drawing tin-plated mild steel with sapphire and cemented carbide dies. Drawing loads and die-separating forces will be presented and movie-films of the action of tracer markings at the interface shown. In order to demonstrate how this data can be used in an analysis of a large strain deformation process with friction, initial results from running the FIPDEF elasto-plastic code will be discussed. From a commercial viewpoint research on strip-drawing is of special interest to the can-making industry. From a physical viewpoint stripdrawing is of particular interest because it is a symmetrical, plane strain deformation and, in comparison with other metal processing operations, it is more readily modeled. However, until now the elasto-plastic codes that have been developed to predictively model drawing have had limitations: the most notable being that of quantifying the friction conditions at the die-work interface. Hence the specification of the

  11. Strip specimen tests for pipeline materials and girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, William C. [Edison Welding Institute (EWI), Columbus, Ohio (United States)

    2009-07-01

    Strip specimen testing of pipeline materials has been widely applied as a method of getting data relevant to the performance of pipelines under axial direction loading. Comparisons of strip specimen against smaller standard tests (round tensile bar, fracture toughness specimens, polished round bars) and against full-scale or large-scale testing will be explored. Data from early-generation pipe welds from the 1920's to the 1940's to the most recent materials for offshore reeled pipe will be used for examples. Strip samples can provide full thickness information to take account of varying material properties or imperfection distribution through the thickness. Strip samples can also accommodate measurement of effects of the original surface finish or weld surface shape. Strip samples have more design flexibility than standard tests, but must be designed to limit stress concentrations and effects of local bending. (author)

  12. A Combined Control Chart for Identifying Out–Of–Control Points in Multivariate Processes

    Directory of Open Access Journals (Sweden)

    Marroquín–Prado E.

    2010-10-01

    Full Text Available The Hotelling's T2 control chart is widely used to identify out–of–control signals in multivariate processes. However, this chart is not sensitive to small shifts in the process mean vec tor. In this work we propose a control chart to identify out–of–control signals. The proposed chart is a combination of Hotelling's T2 chart, M chart proposed by Hayter et al. (1994 and a new chart based on Principal Components. The combination of these charts identifies any type and size of change in the process mean vector. Us ing simulation and the Average Run Length (ARL, the performance of the proposed control chart is evaluated. The ARL means the average points within control before an out–of–control point is detected, The results of the simulation show that the proposed chart is more sensitive that each one of the three charts individually

  13. Fatigue of graphite/epoxy buffer strip panels with center cracks

    Science.gov (United States)

    Bigelow, C. A.

    1985-01-01

    The effects of fatigue loading on the behavior of graphite/epoxy panels with either S-Glass or Kevlar-49 buffer strips is studied. Buffer strip panels are fatigued and tested in tension to measure their residual strength with crack-like damage. Panels are made with 45/0/-45/90 sub 2s layup with either S-Glass or Kevlar-49 buffer strip material. The buffer strips are parallel to the loading direction and made by replacing narrow strips of the 0-degree graphite plies with strips of either 0-degree S-Glass/epoxy or Kevlar-49/epoxy on a one-for-one basis. The panels are subjected to a fatigue loading spectrum MINITWIST, the shortened version of the standardized load program for the wing lower surface of a transport aircraft. Two levels of maximum strain are used in the spectrum with three durations of the fatigue spectrum. One group of panels is preloaded prior to the application of the fatigue cycling. The preload consists of statistically loading the spectrum in tension until the crack-tip damage zone reaches the ajacent buffer strips. After fatigue loading, all specimens are statistically loaded in tension to failure to determine their residual strengths.

  14. 47 CFR 73.599 - NCE-FM engineering charts.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false NCE-FM engineering charts. 73.599 Section 73.599 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Noncommercial Educational FM Broadcast Stations § 73.599 NCE-FM engineering charts. This...

  15. Photosensitive Strip RETHGEM

    CERN Document Server

    Peskov, Vladimir; Nappi, E.; Oliveira, R.; Paic, G.; Pietropaolo, F.; Picchi, P.

    2008-01-01

    An innovative photosensitive gaseous detector, consisting of a GEM like amplification structure with double layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our latest designs, the inner electrode consists of a metallic grid and the outer one is made of resistive strips; the latter are manufactured by a screen printing technology on the top of the metallic strips grid The inner metallic grid is used for 2D position measurements whereas the resistive layer provides an efficient spark protected operation at high gains - close to the breakdown limit. Detectors with active areas of 10cm x10cm and 10cm x20cm were tested under various conditions including the operation in photosensitive gas mixtures containing ethylferrocene or TMAE vapors. The new technique could have many applications requiring robust and reliable large area detectors for UV visualization, as for example, in Cherenkov imaging devices.

  16. Nanoscale Test Strips for Multiplexed Blood Analysis

    Science.gov (United States)

    Chan, Eugene

    2015-01-01

    A critical component of the DNA Medicine Institute's Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) sensor are nanoscale test strips, or nanostrips, that enable multiplexed blood analysis. Nanostrips are conceptually similar to the standard urinalysis test strip, but the strips are shrunk down a billionfold to the microscale. Each nanostrip can have several sensor pads that fluoresce in response to different targets in a sample. The strips carry identification tags that permit differentiation of a specific panel from hundreds of other nanostrip panels during a single measurement session. In Phase I of the project, the company fabricated, tested, and demonstrated functional parathyroid hormone and vitamin D nanostrips for bone metabolism, and thrombin aptamer and immunoglobulin G antibody nanostrips. In Phase II, numerous nanostrips were developed to address key space flight-based medical needs: assessment of bone metabolism, immune response, cardiac status, liver metabolism, and lipid profiles. This unique approach holds genuine promise for space-based portable biodiagnostics and for point-of-care (POC) health monitoring and diagnostics here on Earth.

  17. Clinical Evaluation of an Adhesive Sealant for Controlling Dental Caries in Naval Personnel: One-Year Results

    Science.gov (United States)

    1974-08-20

    safeguards were employed in that a voltage monitoring strip chart recorder was employed during sealant placement to ensure continuous delivery of...adequate voltage to the ultraviolet light source (Nuva- Lite)* used for sealant polymerization. Also, a new air compressor** with suitable...ment effect in young Naval personnel. 2. The very low occlusal attack rate for untreated control teeth 3. Dirks, O. B., Houwink, B. and Kwant , G. W

  18. Data acquisition software for the CMS strip tracker

    International Nuclear Information System (INIS)

    Bainbridge, R; Cripps, N; Fulcher, J; Radicci, V; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Gill, K; Mirabito, L; Cole, J; Jesus, A C A; Giassi, A; Giordano, D; Gross, L; Hahn, K; Mersi, S; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS silicon strip tracker, providing a sensitive area of approximately 200 m 2 and comprising 10 million readout channels, has recently been completed at the tracker integration facility at CERN. The strip tracker community is currently working to develop and integrate the online and offline software frameworks, known as XDAQ and CMSSW respectively, for the purposes of data acquisition and detector commissioning and monitoring. Recent developments have seen the integration of many new services and tools within the online data acquisition system, such as event building, online distributed analysis, an online monitoring framework, and data storage management. We review the various software components that comprise the strip tracker data acquisition system, the software architectures used for stand-alone and global data-taking modes. Our experiences in commissioning and operating one of the largest ever silicon micro-strip tracking systems are also reviewed

  19. The development of drift-strip detectors based on CdZnTe

    DEFF Research Database (Denmark)

    Gostilo, V.; Budtz-Jørgensen, Carl; Kuvvetli, Irfan

    2002-01-01

    The design and technological development of a CdZnTe drift strip detector is described. The device is based on a monocrystal of dimensions 10 x 10 x 3 mm(3) and has a pitch of 200 mum and a strip width of 100 mum. The strip length is 9.5 mm. The distribution of the leakage currents of the strips...

  20. Intraclass reliability for assessing how well Taiwan constrained hospital-provided medical services using statistical process control chart techniques.

    Science.gov (United States)

    Chien, Tsair-Wei; Chou, Ming-Ting; Wang, Wen-Chung; Tsai, Li-Shu; Lin, Weir-Sen

    2012-05-15

    Few studies discuss the indicators used to assess the effect on cost containment in healthcare across hospitals in a single-payer national healthcare system with constrained medical resources. We present the intraclass correlation coefficient (ICC) to assess how well Taiwan constrained hospital-provided medical services in such a system. A custom Excel-VBA routine to record the distances of standard deviations (SDs) from the central line (the mean over the previous 12 months) of a control chart was used to construct and scale annual medical expenditures sequentially from 2000 to 2009 for 421 hospitals in Taiwan to generate the ICC. The ICC was then used to evaluate Taiwan's year-based convergent power to remain unchanged in hospital-provided constrained medical services. A bubble chart of SDs for a specific month was generated to present the effects of using control charts in a national healthcare system. ICCs were generated for Taiwan's year-based convergent power to constrain its medical services from 2000 to 2009. All hospital groups showed a gradually well-controlled supply of services that decreased from 0.772 to 0.415. The bubble chart identified outlier hospitals that required investigation of possible excessive reimbursements in a specific time period. We recommend using the ICC to annually assess a nation's year-based convergent power to constrain medical services across hospitals. Using sequential control charts to regularly monitor hospital reimbursements is required to achieve financial control in a single-payer nationwide healthcare system.

  1. On the Mathematics behind the CUSUM Control Charts

    DEFF Research Database (Denmark)

    Madsen, Henrik

    1998-01-01

    This paper describes the mathematics behind CUSUM control charts. An introduction to CUSUM charts is found in (Madsen 1998).CUSUM charts are well suited for checking a measuring system in operation for any departure from some target or specified values. In general they can be used for:- detecting...... a drift (or shift in the level) of the measuring system, and- detecting a change of the precision of the measuring system.In both cases the CUSUM procedure contains methods for estimating the shift such that maintenance (e.g. recalibration) can take place.The CUSUM procedure is described in ISO/CD 7871...

  2. Embedded pitch adapters: A high-yield interconnection solution for strip sensors

    Energy Technology Data Exchange (ETDEWEB)

    Ullán, M., E-mail: miguel.ullan@imb-cnm.csic.es [Centro Nacional de Microelectronica (IMB-CNM, CSIC), Campus UAB-Bellaterra, 08193 Barcelona (Spain); Allport, P.P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J.P.; Wilson, J.A. [School of Physics and Astronomy, University of Birmingham, Birmingham B15 2TT (United Kingdom); Kierstead, J.; Kuczewski, P.; Lynn, D. [Brookhaven National Laboratory, Physics Department and Instrumentation Division, Upton, NY 11973-5000 (United States); Hommels, L.B.A. [Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Fleta, C.; Fernandez-Tejero, J.; Quirion, D. [Centro Nacional de Microelectronica (IMB-CNM, CSIC), Campus UAB-Bellaterra, 08193 Barcelona (Spain); Bloch, I.; Díez, S.; Gregor, I.M.; Lohwasser, K. [DESY, Notkestrasse 85, 22607 Hamburg (Germany); and others

    2016-09-21

    A proposal to fabricate large area strip sensors with integrated, or embedded, pitch adapters is presented for the End-cap part of the Inner Tracker in the ATLAS experiment. To implement the embedded pitch adapters, a second metal layer is used in the sensor fabrication, for signal routing to the ASICs. Sensors with different embedded pitch adapters have been fabricated in order to optimize the design and technology. Inter-strip capacitance, noise, pick-up, cross-talk, signal efficiency, and fabrication yield have been taken into account in their design and fabrication. Inter-strip capacitance tests taking into account all channel neighbors reveal the important differences between the various designs considered. These tests have been correlated with noise figures obtained in full assembled modules, showing that the tests performed on the bare sensors are a valid tool to estimate the final noise in the full module. The full modules have been subjected to test beam experiments in order to evaluate the incidence of cross-talk, pick-up, and signal loss. The detailed analysis shows no indication of cross-talk or pick-up as no additional hits can be observed in any channel not being hit by the beam above 170 mV threshold, and the signal in those channels is always below 1% of the signal recorded in the channel being hit, above 100 mV threshold. First results on irradiated mini-sensors with embedded pitch adapters do not show any change in the interstrip capacitance measurements with only the first neighbors connected.

  3. Eddy current distribution and lift force for finite MAGLEV strips

    Energy Technology Data Exchange (ETDEWEB)

    Atherton, D L; Eastham, A R; Fombrun, C; Chong, M

    1974-07-01

    The transverse distribution of induced eddy currents across a flat conducing strip of finite width, due to a rectangular dc magnet moving above it, was modelled experimentally, and was compared with that calculated for an infinite sheet. The electrodynamic suspension was simulated by means of a stationary ac-excited copper magnet suspended above an aluminum strip, and the induced surface current density was measured by a voltage pickup probe connected to a lock-in amplifier. The effect of reducing strip width is examined and shown to produce high current densities close to the edges. These results are related to the variation of lift force with strip width, determined by impedance modelling. A slight enhancement of lift is evident for intermediate strip widths.

  4. Technique charts for EC film: direct optical measurements to account for the effects of X-ray scatter

    International Nuclear Information System (INIS)

    Munro, Peter; Jordan, Kevin; Lewis, Craig; Heerema, Tim

    2001-01-01

    -ray scatter can generate a large fraction of the signals recorded by the EC film. Technique charts have been generated at 4 MV and 6 MV, and these charts should have universal applicability

  5. Deuteron stripping reactions using dirac phenomenology

    Science.gov (United States)

    Hawk, E. A.; McNeil, J. A.

    2001-04-01

    In this work deuteron stripping reactions are studied using the distorted wave born approximation employing dirac phenomenological potentials. In 1982 Shepard and Rost performed zero-range dirac phenomenological stripping calculations and found a dramatic reduction in the predicted cross sections when compared with similar nonrelativistic calculations. We extend the earlier work by including full finite range effects as well as the deuteron's internal D-state. Results will be compared with traditional nonrelativistic approaches and experimental data at low energy.

  6. LYCORIS - A Large Area Strip Telescope

    CERN Document Server

    Krämer, U; Stanitzki, M; Wu, M

    2018-01-01

    The LYCORIS Large Area Silicon Strip Telescope for the DESY II Test Beam Facility is presented. The DESY II Test Beam Facility provides elec- tron and positron beams for beam tests of up to 6 GeV. A new telescope with a large 10 × 20 cm2 coverage area based on a 25 μm pitch strip sensor is to be installed within the PCMAG 1 T solenoid. The current state of the system is presented.

  7. Combined effect of bulk and surface damage on strip insulation properties of proton irradiated n$^{+}$-p silicon strip sensors

    CERN Document Server

    Dalal, R; Ranjan, K; Moll, M; Elliott-Peisert, A

    2014-01-01

    Silicon sensors in next generation hadron colliders willface a tremendously harsh radiation environment. Requirement tostudy rarest reaction channels with statistical constraints hasresulted in a huge increment in radiation flux, resulting in bothsurface damage and bulk damage. For sensors which are used in acharged hadron environment, both of these degrading processes takeplace simultaneously. Recently it has been observed in protonirradiated n$^{+}$-p Si strip sensors that n$^{+}$ strips had a goodinter-strip insulation with low values of p-spray and p-stop dopingdensities which is contrary to the expected behaviour from thecurrent understanding of radiation damage. In this work a simulationmodel has been devised incorporating radiation damage to understandand provide a possible explanation to the observed behaviour ofirradiated sensors.

  8. Retrospective chart review of elderly patients receiving electroconvulsive therapy in a tertiary general hospital

    OpenAIRE

    Mosam Phirke; Harshal Sathe; Nilesh Shah; Sushma Sonavane; Anup Bharati; Avinash DeSousa

    2015-01-01

    Background: Electroconvulsive therapy (ECT) is the one of the oldest and effective treatments in psychiatry today. It has been used in a wide variety of psychiatric disorders in both young and old patients. Aims of the study: The present study is a retrospective chart review of geriatric patients receiving ECT as a treatment option in a tertiary care general hospital psychiatry setting. Methodology: The study evaluated ECT records over a 5-year period between the years 2010 and 2014...

  9. Beam loss studies on silicon strip detector modules for the CMS experiment

    CERN Document Server

    Fahrer, Manuel

    2006-01-01

    The large beam energy of the LHC demands for a save beam abort system. Nevertheless, failures cannot be excluded with last assurance and are predicted to occur once per year. As the CMS experiment is placed in the neighboured LHC octant, it is affected by such events. The effect of an unsynchronized beam abort on the silicon strip modules of the CMS tracking detector has been investigated in this thesis by performing one accelerator and two lab experiments. The dynamical behaviour of operational parameters of modules and components has been recorded during simulated beam loss events to be able to disentangle the reasons of possible damages. The first study with high intensive proton bunches at the CERN PS ensured the robustness of the module design against beam losses. A further lab experiment with pulsed IR LEDs clarified the physical and electrical processes during such events. The silicon strip sensors on a module are protected against beam losses by a part of the module design that originally has not been...

  10. Accuracy of nurse documentation of delirium symptoms in medical charts.

    Science.gov (United States)

    Voyer, Philippe; Cole, Martin G; McCusker, Jane; St-Jacques, Sylvie; Laplante, Johanne

    2008-04-01

    The purpose of this study undertaken in an acute care hospital was to evaluate sensitivity and specificity of the documentation of nurse-reported delirium symptoms in medical charts. This is a descriptive study based on the clinical assessments of a study nurse and nursing notes in the medical charts of 226 delirious older patients newly admitted to an acute care hospital. The results of this prospective validation study indicated that documentation of delirium symptoms is poor. Disorientation, agitation and altered level of consciousness were the three symptoms yielding a higher level of sensitivity, but even so said symptoms were reported in less than a third of the medical charts. Univariate analysis suggested that higher comorbidity level, more severe symptoms of delirium and the use of physical restraints were associated with more valid documentation of delirium symptoms in medical charts. Lastly, this study corroborates results of previous studies, indicating that documentation of delirium symptoms in medical charts can be improved. Future study should target improving nurse documentation of delirium symptoms in medical charts.

  11. Negative Binomial charts for monitoring high-quality processes

    NARCIS (Netherlands)

    Albers, Willem/Wim

    Good control charts for high quality processes are often based on the number of successes between failures. Geometric charts are simplest in this respect, but slow in recognizing moderately increased failure rates p. Improvement can be achieved by waiting until r > 1 failures have occurred, i.e. by

  12. Induction heating in in-line strip production process

    International Nuclear Information System (INIS)

    Costa, P.; Santinelli, M.

    1995-05-01

    ISP (In-line Strip Production), a continuous process for steel strip production, has recently been set in an italian innovative plant, where ecological impact and power requirements are lighter than usual. This report describes the studies performed by ENEA (Italian Agency for New Technologies, Energy and the Environment), while a prototype reheating facility was arranged by Acciaieria ISP in Cremona (Italy). The authors, after a study of the prototype electromagnetic field, calculate the heating rate, with the thermal network method. Then they detect, with a 1-D-FEM, the heat diffusion through the strip cross section. Afterward, since the heat distribution depends on the eddy current density one, which is given by the magnetic field distribution, the authors, with a 3-D-FEM, carry out a coupled, electromagnetic and thermal, analysis in time domain. The strip temperature map is established by the balance between skin depth heating and surface cooling: a thermal analysis, performed with a moving 2-D-FEM, take into account the effects of the different heating and cooling situations, originated by the strip moving at a speed of 6m/min through four consecutive reheating facilities. The temperatures of a strip sample heated by the prototype have been monitored, acquired by a computer and related with the simulation results. The little difference between experiment and simulation assessed the qualitative and quantitative validity of this analysis, that has come out to be a tool, useful to evaluate the effects of possible improvements to the ISP process

  13. Analysis of 'Coma strip' galaxy redshift catalog

    International Nuclear Information System (INIS)

    Klypin, A.A.; Karachentsev, I.D.; Lebedev, V.S.

    1990-01-01

    We present results of the analysis of a galaxy redshift catalog made at the 6-m telescope by Karachentsev and Kopylov (1990. Mon. Not. R. astr. Soc., 243, 390). The catalog covers a long narrow strip on the sky (10 arcmin by 63 0 ) and lists 283 galaxies up to limiting blue magnitude m B = 17.6. The strip goes through the core of Coma cluster and this is called the 'Coma strip' catalog. The catalog is almost two times deeper than the CfA redshift survey and creates the possibility of studying the galaxy distribution on scales of 100-250 Mpc. Due to the small number of galaxies in the catalog, we were able to estimate only very general and stable parameters of the distribution. (author)

  14. 48 CFR 252.245-7000 - Government-furnished mapping, charting, and geodesy property.

    Science.gov (United States)

    2010-10-01

    ... mapping, charting, and geodesy property. 252.245-7000 Section 252.245-7000 Federal Acquisition Regulations..., charting, and geodesy property. As prescribed in 245.107-70, use the following clause: Government-Furnished Mapping, Charting, and Geodesy Property (DEC 1991) (a) Definition—Mapping, charting, and geodesy (MC&G...

  15. 31 CFR 356.31 - How does the STRIPS program work?

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false How does the STRIPS program work? 356.31 Section 356.31 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued...) Miscellaneous Provisions § 356.31 How does the STRIPS program work? (a) General. Notes or bonds may be “stripped...

  16. Using Comic Strips as a Book Report Alternative

    Science.gov (United States)

    Reading Teacher, 2012

    2012-01-01

    Comic strips are great to share with parents, younger students, and peers. This article presents an activity where students use a six-paneled comic strip to summarize a story. This activity allows for multiple interpretations and enhances comprehension by drawing attention to story elements.

  17. Development of disease-specific growth charts in Turner syndrome and Noonan syndrome

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Isojima

    2017-12-01

    Full Text Available Many congenital diseases are associated with growth failure, and patients with these diseases have specific growth patterns. As the growth patterns of affected individuals differ from those of normal populations, it is challenging to detect additional conditions that can influence growth using standard growth charts. Disease-specific growth charts are thus very useful tools and can be helpful for understanding the growth pattern and pathogenesis of congenital diseases. In addition, disease-specific growth charts allow doctors to detect deviations from the usual growth patterns for early diagnosis of an additional condition and can be used to evaluate the effects of growth-promoting treatment for patients. When developing these charts, factors that can affect the reliability of the charts should be considered. These factors include the definition of the disease with growth failure, selection bias in the measurements used to develop the charts, secular trends of the subjects, the numbers of subjects of varying ages and ethnicities, and the statistical method used to develop the charts. In this review, we summarize the development of disease-specific growth charts for Japanese individuals with Turner syndrome and Noonan syndrome and evaluate the efforts to collect unbiased measurements of subjects with these diseases. These charts were the only available disease-specific growth charts of Turner syndrome and Noonan syndrome for Asian populations and were developed using a Japanese population. Therefore, when these charts are adopted for Asian populations other than Japanese, different growth patterns should be considered.

  18. Development of disease-specific growth charts in Turner syndrome and Noonan syndrome.

    Science.gov (United States)

    Isojima, Tsuyoshi; Yokoya, Susumu

    2017-12-01

    Many congenital diseases are associated with growth failure, and patients with these diseases have specific growth patterns. As the growth patterns of affected individuals differ from those of normal populations, it is challenging to detect additional conditions that can influence growth using standard growth charts. Disease-specific growth charts are thus very useful tools and can be helpful for understanding the growth pattern and pathogenesis of congenital diseases. In addition, disease-specific growth charts allow doctors to detect deviations from the usual growth patterns for early diagnosis of an additional condition and can be used to evaluate the effects of growth-promoting treatment for patients. When developing these charts, factors that can affect the reliability of the charts should be considered. These factors include the definition of the disease with growth failure, selection bias in the measurements used to develop the charts, secular trends of the subjects, the numbers of subjects of varying ages and ethnicities, and the statistical method used to develop the charts. In this review, we summarize the development of disease-specific growth charts for Japanese individuals with Turner syndrome and Noonan syndrome and evaluate the efforts to collect unbiased measurements of subjects with these diseases. These charts were the only available disease-specific growth charts of Turner syndrome and Noonan syndrome for Asian populations and were developed using a Japanese population. Therefore, when these charts are adopted for Asian populations other than Japanese, different growth patterns should be considered.

  19. Interactive SIGHT: textual access to simple bar charts

    Science.gov (United States)

    Demir, Seniz; Oliver, David; Schwartz, Edward; Elzer, Stephanie; Carberry, Sandra; Mccoy, Kathleen F.; Chester, Daniel

    2010-12-01

    Information graphics, such as bar charts and line graphs, are an important component of many articles from popular media. The majority of such graphics have an intention (a high-level message) to communicate to the graph viewer. Since the intended message of a graphic is often not repeated in the accompanying text, graphics together with the textual segments contribute to the overall purpose of an article and cannot be ignored. Unfortunately, these visual displays are provided in a format which is not readily accessible to everyone. For example, individuals with sight impairments who use screen readers to listen to documents have limited access to the graphics. This article presents a new accessibility tool, the Interactive SIGHT (Summarizing Information GrapHics Textually) system, that is intended to enable visually impaired users to access the knowledge that one would gain from viewing information graphics found on the web. The current system, which is implemented as a browser extension that works on simple bar charts, can be invoked by a user via a keystroke combination while navigating the web. Once launched, Interactive SIGHT first provides a brief summary that conveys the underlying intention of a bar chart along with the chart's most significant and salient features, and then produces history-aware follow-up responses to provide further information about the chart upon request from the user. We present two user studies that were conducted with sighted and visually impaired users to determine how effective the initial summary and follow-up responses are in conveying the informational content of bar charts, and to evaluate how easy it is to use the system interface. The evaluation results are promising and indicate that the system responses are well-structured and enable visually impaired users to answer key questions about bar charts in an easy-to-use manner. Post-experimental interviews revealed that visually impaired participants were very satisfied with

  20. The effectiveness of robust RMCD control chart as outliers’ detector

    Science.gov (United States)

    Darmanto; Astutik, Suci

    2017-12-01

    A well-known control chart to monitor a multivariate process is Hotelling’s T 2 which its parameters are estimated classically, very sensitive and also marred by masking and swamping of outliers data effect. To overcome these situation, robust estimators are strongly recommended. One of robust estimators is re-weighted minimum covariance determinant (RMCD) which has robust characteristics as same as MCD. In this paper, the effectiveness term is accuracy of the RMCD control chart in detecting outliers as real outliers. In other word, how effectively this control chart can identify and remove masking and swamping effects of outliers. We assessed the effectiveness the robust control chart based on simulation by considering different scenarios: n sample sizes, proportion of outliers, number of p quality characteristics. We found that in some scenarios, this RMCD robust control chart works effectively.

  1. Magnetic ring for stripping enhancement

    International Nuclear Information System (INIS)

    Selph, F.

    1992-10-01

    A ring designed to recycle ions through a stripping medium offers the possibility for increasing output of the desired charge state by up to 4x. This could be a very important component of a Radioactive Nuclear Beam Facility. In order for such a ring to work effectively it must satisfy certain design conditions. These include achromaticity at the stripper, a dispersed region for an extraction magnet, and a number of first and higher order optics constraints which are necessary to insure that the beam emittance is not degraded unduly by the ring. An example is given of a candidate design of a stripping ring

  2. The lung parenchymal strip as a model of peripheral airway responsiveness.

    Science.gov (United States)

    Armour, C L; Black, J L; Berend, N

    1985-01-01

    Twenty-four patients scheduled for surgery for carcinoma of the lung were challenged with inhaled methacholine. A greater than 20% fall in the forced expiratory volume in 1 s (FEV1) was recorded in nine of these patients. The PD20 (dose of methacholine producing a 20% fall in FEV1) values ranged from 0.6 to 5.6 mumol methacholine. Following surgery, lung tissue was prepared as lung parenchymal strips for in vitro studies. There was no correlation between in vivo airway responsiveness to methacholine (PD20) and in vitro sensitivity as measured by the EC50 (the concentration of agonist producing half the maximal tension [Tmax]) for carbachol (r = -0.17; n = 16) or histamine (r = 0.23; n = 24). The variation in in vivo and in vitro responsiveness was not due to the presence of inflammatory cells in the peripheral lung tissue. Of the 38 lung parenchymal strips studied with histamine, 17 demonstrated a variable relaxation response at low concentrations followed by contraction at higher concentrations. The presence or absence of this relaxation response could not be explained in terms of variable proportions of airway or vascular smooth muscle.

  3. Investigation on Shock Induced Stripping Breakup Process of A Liquid Droplet

    KAUST Repository

    Liu, Yao

    2017-03-02

    Stripping breakup process of a single liquid droplet under the impact of a planar shock wave is investigated both experimentally and numerically. The droplet breakup experiment is conducted in a horizontal shock tube and the evolution of the droplet is recorded by direct high-speed photography. The experimental images clearly illustrate the droplet interface evolution features from its early to relatively late stage. Compressible Euler equations are solved using an in-house inviscid upwind characteristic space-time conservation element and solution element (CE/SE) method coupled with the HLLC approximate Riemann solver. A reduced five-equation model is employed to demonstrate the air/liquid interface. Numerical results accurately reproduce the water column and axi-symmetric water droplet breakup processes in experiments. The present study confirms the validity of the present numerical method in solving the shock wave induced droplet breakup problem and elaborates the stripping breakup process numerically in a long period. Droplet inner flow pattern is depicted, based on which the drives of protrusions emerged on the droplet surface are clearly seen. The droplet deformation is proved to be determined by not only the outer air flow, but also the inner liquid flow.

  4. Investigation on Shock Induced Stripping Breakup Process of A Liquid Droplet

    KAUST Repository

    Liu, Yao; Wen, Chihyung; Shen, Hua; Guan, Ben

    2017-01-01

    Stripping breakup process of a single liquid droplet under the impact of a planar shock wave is investigated both experimentally and numerically. The droplet breakup experiment is conducted in a horizontal shock tube and the evolution of the droplet is recorded by direct high-speed photography. The experimental images clearly illustrate the droplet interface evolution features from its early to relatively late stage. Compressible Euler equations are solved using an in-house inviscid upwind characteristic space-time conservation element and solution element (CE/SE) method coupled with the HLLC approximate Riemann solver. A reduced five-equation model is employed to demonstrate the air/liquid interface. Numerical results accurately reproduce the water column and axi-symmetric water droplet breakup processes in experiments. The present study confirms the validity of the present numerical method in solving the shock wave induced droplet breakup problem and elaborates the stripping breakup process numerically in a long period. Droplet inner flow pattern is depicted, based on which the drives of protrusions emerged on the droplet surface are clearly seen. The droplet deformation is proved to be determined by not only the outer air flow, but also the inner liquid flow.

  5. Nurse Educators' Consensus Opinion on Using an Academic Electronic Health Record: A Delphi Study

    Science.gov (United States)

    Hanson, Darlene S.

    2013-01-01

    The purpose of this study was to determine the opinions of nurse educators in the state of North Dakota (ND) who were using the academic Electronic Health Record (EHR) known as SimChart. In this dissertation research study, factors that either hindered or facilitated the introduction of SimChart in nursing programs in ND were examined.…

  6. Charting Transnational Native American Studies

    Directory of Open Access Journals (Sweden)

    Hsinya Huang

    2012-06-01

    Full Text Available Introduction to the Special Forum entitled "Charting Transnational Native American Studies: Aesthetics, Politics, Identity," edited by Hsinya Huang, Philip J. Deloria, Laura M. Furlan, and John Gamber

  7. Do repeated rumble strip hits improve driver alertness?

    NARCIS (Netherlands)

    Watling, C.N.; Akerstedt, T.; Kecklund, L.G.; Anund, A.

    2016-01-01

    Driving while sleepy is associated with increased crash risk. Rumble strips are designed to alert a sleepy or inattentive driver when they deviate outside their driving lane. The current study sought to examine the effects of repeated rumble strip hits on levels of physiological and subjective

  8. Quality Control Charts in Large-Scale Assessment Programs

    Science.gov (United States)

    Schafer, William D.; Coverdale, Bradley J.; Luxenberg, Harlan; Jin, Ying

    2011-01-01

    There are relatively few examples of quantitative approaches to quality control in educational assessment and accountability contexts. Among the several techniques that are used in other fields, Shewart charts have been found in a few instances to be applicable in educational settings. This paper describes Shewart charts and gives examples of how…

  9. 46 CFR 109.565 - Charts and nautical publications.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Charts and nautical publications. 109.565 Section 109... OPERATIONS Miscellaneous § 109.565 Charts and nautical publications. The master or person in charge of a self...) Notices to mariners. (f) Tide Tables. (g) Current Tables. (h) All other nautical publications necessary. 1...

  10. Evaluation of anatomy comic strips for further production and applications

    Science.gov (United States)

    Shin, Dong Sun; Kim, Dae Hyun; Park, Jin Seo; Jang, Hae Gwon

    2013-01-01

    The corresponding author of the study has been sketching comic strips to explain anatomy in a humorous manner. All the anatomy comic strips, including those in Korean (650 episodes) and English (451 episodes), can be viewed on the homepage (http://anatomy.co.kr). Such comic strips were created with the aim of assisting medical students. However, their impact was unknown, and therefore, we surveyed the students' responses. We noted that anatomy grades were better in the students who read the comic strips. The comics helped the trainees chat with individuals with and without a medical background. The authors also considered comments on the problems with the comic strips and attempted to find solutions. The episodes are being currently used and further produced for educational purposes. To support this effort, the readers' valuable opinions will be continuously collected and assessed. PMID:24179697

  11. Evaluation of anatomy comic strips for further production and applications.

    Science.gov (United States)

    Shin, Dong Sun; Kim, Dae Hyun; Park, Jin Seo; Jang, Hae Gwon; Chung, Min Suk

    2013-09-01

    The corresponding author of the study has been sketching comic strips to explain anatomy in a humorous manner. All the anatomy comic strips, including those in Korean (650 episodes) and English (451 episodes), can be viewed on the homepage (http://anatomy.co.kr). Such comic strips were created with the aim of assisting medical students. However, their impact was unknown, and therefore, we surveyed the students' responses. We noted that anatomy grades were better in the students who read the comic strips. The comics helped the trainees chat with individuals with and without a medical background. The authors also considered comments on the problems with the comic strips and attempted to find solutions. The episodes are being currently used and further produced for educational purposes. To support this effort, the readers' valuable opinions will be continuously collected and assessed.

  12. The charge collection in silicon strip detectors

    International Nuclear Information System (INIS)

    Boehringer, T.; Hubbeling, L.; Weilhammer, P.; Kemmer, J.; Koetz, U.; Riebesell, M.; Belau, E.; Klanner, R.; Lutz, G.; Neugebauer, E.; Seebrunner, H.J.; Wylie, A.

    1983-02-01

    The charge collection in silicon detectors has been studied, by measuring the response to high-energy particles of a 20μm pitch strip detector as a function of applied voltage and magnetic field. The results are well described by a simple model. The model is used to predict the spatial resolution of silicon strip detectors and to propose a detector with optimized spatial resolution. (orig.)

  13. An Assessment of Statistical Process Control-Based Approaches for Charting Student Evaluation Scores

    Science.gov (United States)

    Ding, Xin; Wardell, Don; Verma, Rohit

    2006-01-01

    We compare three control charts for monitoring data from student evaluations of teaching (SET) with the goal of improving student satisfaction with teaching performance. The two charts that we propose are a modified "p" chart and a z-score chart. We show that these charts overcome some of the shortcomings of the more traditional charts…

  14. Monitoring a PVC batch process with multivariate statistical process control charts

    NARCIS (Netherlands)

    Tates, A. A.; Louwerse, D. J.; Smilde, A. K.; Koot, G. L. M.; Berndt, H.

    1999-01-01

    Multivariate statistical process control charts (MSPC charts) are developed for the industrial batch production process of poly(vinyl chloride) (PVC). With these MSPC charts different types of abnormal batch behavior were detected on-line. With batch contribution plots, the probable causes of these

  15. 40 CFR 86.542-90 - Records required.

    Science.gov (United States)

    2010-07-01

    ... Charts: Identify zero, span, exhaust gas, and dilution air sample traces. (j) Test cell barometric... variations. (m) The number of revolutions of the positive displacement pump accumulated during each test... critical flow venturi during each test phase would be the equivalent record for a CFV-CVS. (n) The humidity...

  16. Refuges, flower strips, biodiversity and agronomic interest.

    Science.gov (United States)

    Roy, Grégory; Wateau, Karine; Legrand, Mickaël; Oste, Sandrine

    2008-01-01

    Several arthropods are natural predators of pests, and they are able to reduce and control their population development. FREDON Nord Pas-de-Calais (Federation Regionate de Defense contre les Organismes Nuisibles = Regional Federation for Pest Control) has begun for a long time to form farmers to the recognition of beneficial arthropods and to show them their usefulness. These beneficial insects or arachnids are present everywhere, in orchards and even in fields which are areas relatively poor in biodiversity. Adults feed in the flower strips instead larvae and some adults feed on preys such as aphids or caterpillars. Most of the time, beneficial insects can regulate pest but sometimes, in agricultural area, they can't make it early enough and efficiently. Their action begin too late and there biodiversity and number are too low. It's possible to enhance their action by manipulating the ecological infrastructures, like sewing flower strips or installing refuges. Flower strips increase the density of natural enemies and make them be present earlier in the field in order to control pests. Refuges permit beneficial's to spend winter on the spot. So they're able to be active and to grow in number earlier. From 2004 to 2007, on the one hand, FREDON Nord Pas-de-Calais has developed a research program. Its purpose was to inventory practices and also tools and means available and to judge the advisability of using such or such beneficial refuge in orchards. On the second hand, it studied the impact in orchard of refuges on population of beneficial's and the difference there were between manufactured refuges and homemade refuges. Interesting prospects were obtained with some of them. Otherwise, since 2003, FREDON has studied flower strips influence on beneficial population and their impact on pest control. In cabbage fields, results of trials have shown that flower strips lead to a reduction of aphid number under acceptable economic level, up to 50 meters from flower strips

  17. MO-A-BRB-00: Electronic Charting in EBRT and Brachytherapy

    International Nuclear Information System (INIS)

    2015-01-01

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy

  18. Optimization of the process of steel strip perforation and nickel platting for the purpose of elimination of trichloroethylene from the cleaning process of perforated steel strip

    Directory of Open Access Journals (Sweden)

    Petrović Aleksandra B.

    2009-01-01

    Full Text Available In the production of pocket type electrodes for Ni-Cd batteries perforation of proper steel strips and then nickel platting of perforated steel strips were made. In the nickel platting process, the organic solvent, trichloroethylene, has previously been used for cleaning. Due to the carcinogenic nature of trichloroethylene and the many operations previously required during cleaning, it was considered to do cleaning of perforated steel strips without use of the mentioned organic solvent. In the purpose of elimination of trichloroethylene from the cleaning process of perforated steel strips, the tests of perforation of steel strips with use of oils of different viscosity were made. It was shown that there was no dysfunction during the work of the perforation plants, meaning there was no additional heating of the strips, deterring of the steel filings, nor excessive wearing of the perforation apparatus. The perforation percent was the same irrelevant of the viscosity of the used oil. Before being perforated using the oils with different viscosity, the nickel platting steel strips were cleaned in different degreasers (based on NaOH as well as on KOH. It was shown that efficient cleaning without the use of trichloroethylene is possible with the use of oil with smaller viscosity in the perforated steel strips process and the degreaser based on KOH in the cleaning process, before nickel platting. It also appeared that the alkali degreaser based on KOH was more efficient, bath corrections were made less often and the working period of the baths was longer, which all in summary means less quantity of chemicals needed for degreasing of perforated steel strips.

  19. SU-D-BRD-02: Auto Weekly - An Automated Online Weekly Chart Check System for Medical Physics

    Energy Technology Data Exchange (ETDEWEB)

    Tan, J; Yan, Y; Hager, F; Gu, X; Jia, X; Pompos, A; Foster, R; Stojadinovic, S; Yang, M; Hrycushko, B; Folkerts, M; Zhao, B; Medin, P; Ding, C; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: Radiation therapy has evolved to become not only more precise and potent, but also more complicated to monitor and deliver. More rigorous and comprehensive quality assurance is needed to safeguard ever advancing radiation therapy. ICRU standards dictate that an ever growing set of treatment parameters are manually checked weekly by medical physicists. This “weekly chart check” procedure is laborious and subject to human errors or other factors. A computer-assisted chart checking process will enable more complete and accurate human review of critical parameters, reduce the risk of medical errors, and improve the efficiency. Methods: We developed a web-based software system that enables a thorough weekly quality assurance checks. In the backend, the software retrieves all machine parameters from a Treatment Management System (TMS) and compares them against the corresponding ones from the treatment planning system. They are also checked for validity against preset rules. The results are displayed as a web page in the front-end for physicists to review. Then a summary report is generated and uploaded automatically to the TMS as a record for weekly chart checking. Results: The software system has been deployed on a web server in our department’s intranet, and has been tested thoroughly by our clinical physicists. A plan parameter would be highlighted when it is off the preset limit. The developed system has changed the way of checking charts with significantly improved accuracy, efficiency, and completeness. It has been shown to be robust, fast, and easy to use. Conclusion: A computer-assisted system has been developed for efficient, accurate, and comprehensive weekly chart checking. The system has been extensively validated and is being implemented for routine clinical use.

  20. SU-D-BRD-02: Auto Weekly - An Automated Online Weekly Chart Check System for Medical Physics

    International Nuclear Information System (INIS)

    Tan, J; Yan, Y; Hager, F; Gu, X; Jia, X; Pompos, A; Foster, R; Stojadinovic, S; Yang, M; Hrycushko, B; Folkerts, M; Zhao, B; Medin, P; Ding, C; Jiang, S

    2015-01-01

    Purpose: Radiation therapy has evolved to become not only more precise and potent, but also more complicated to monitor and deliver. More rigorous and comprehensive quality assurance is needed to safeguard ever advancing radiation therapy. ICRU standards dictate that an ever growing set of treatment parameters are manually checked weekly by medical physicists. This “weekly chart check” procedure is laborious and subject to human errors or other factors. A computer-assisted chart checking process will enable more complete and accurate human review of critical parameters, reduce the risk of medical errors, and improve the efficiency. Methods: We developed a web-based software system that enables a thorough weekly quality assurance checks. In the backend, the software retrieves all machine parameters from a Treatment Management System (TMS) and compares them against the corresponding ones from the treatment planning system. They are also checked for validity against preset rules. The results are displayed as a web page in the front-end for physicists to review. Then a summary report is generated and uploaded automatically to the TMS as a record for weekly chart checking. Results: The software system has been deployed on a web server in our department’s intranet, and has been tested thoroughly by our clinical physicists. A plan parameter would be highlighted when it is off the preset limit. The developed system has changed the way of checking charts with significantly improved accuracy, efficiency, and completeness. It has been shown to be robust, fast, and easy to use. Conclusion: A computer-assisted system has been developed for efficient, accurate, and comprehensive weekly chart checking. The system has been extensively validated and is being implemented for routine clinical use

  1. Development of gamma exposure chart (Selenium-75) for Industrial Radiography Application

    International Nuclear Information System (INIS)

    Sapizah Rahim; Shaharudin Sayuti; Noorhazleena Azaman

    2011-01-01

    Radiographic exposure can be determined by either trial exposure, reference to previous data or using exposure chart. Without previous data, exposure chart is the easiest and economic way to achieve correct exposure. It will minimize re-shoot and time. This paper presents the development of gamma exposure chart for Selenium-75 source. Film radiography method has been chosen for this development using steel step wedge blocks. Agfa Structurix D7 films have been used during the exposure and the optical density of the films was measured by using X-Rite densitometer. Method of development of the chart is explained. The chart is tested on pipe and welded plate test sample and the results are discussed. (author)

  2. Charts for Guiding Adjustments of Irrigation Interval to Actual Weather Conditions

    International Nuclear Information System (INIS)

    Kipkorir, E.C.

    2002-01-01

    Major problems in irrigation management at short time-step during the season are unreliability of rainfall and absence of guidance. By considering the climate of region, crop and soil characteristics, the irrigation method and local irrigation practices, this paper presents the concept of irrigation charts. The charts are based on soil water technique. As an example irrigation chart for a typical irrigation system located in the semi-arid area in Naivasha, Kenya is presented. The chart guides the user in adjustment of irrigation interval to the actual weather conditions throughout the growing season. It is believed that the simplicity of the chart makes it a useful tool for a better utilisation of the limited irrigation water

  3. A computer-controlled conformal radiotherapy system. IV: Electronic chart

    International Nuclear Information System (INIS)

    Fraass, Benedick A.; McShan, Daniel L.; Matrone, Gwynne M.; Weaver, Tamar A.; Lewis, James D.; Kessler, Marc L.

    1995-01-01

    Purpose: The design and implementation of a system for electronically tracking relevant plan, prescription, and treatment data for computer-controlled conformal radiation therapy is described. Methods and Materials: The electronic charting system is implemented on a computer cluster coupled by high-speed networks to computer-controlled therapy machines. A methodical approach to the specification and design of an integrated solution has been used in developing the system. The electronic chart system is designed to allow identification and access of patient-specific data including treatment-planning data, treatment prescription information, and charting of doses. An in-house developed database system is used to provide an integrated approach to the database requirements of the design. A hierarchy of databases is used for both centralization and distribution of the treatment data for specific treatment machines. Results: The basic electronic database system has been implemented and has been in use since July 1993. The system has been used to download and manage treatment data on all patients treated on our first fully computer-controlled treatment machine. To date, electronic dose charting functions have not been fully implemented clinically, requiring the continued use of paper charting for dose tracking. Conclusions: The routine clinical application of complex computer-controlled conformal treatment procedures requires the management of large quantities of information for describing and tracking treatments. An integrated and comprehensive approach to this problem has led to a full electronic chart for conformal radiation therapy treatments

  4. Polymer Inclusion Membranes with Strip Dispersion

    Directory of Open Access Journals (Sweden)

    Yueh-Hsien Li

    2017-06-01

    Full Text Available The present work investigated the permeation of indium ions through a polymer inclusion membrane (PIM, prepared with cellulose triacetate (CTA as the base polymer, tris(2-butoxyethyl phosphate (TBEP as the plasticizer and di-(2-ethylhexylphosphoric acid (D2EHPA as the extractant. With 5 M HCl aqueous solution as the strip solution, we observed an initial indium permeability of 2.4 × 10−4 m/min. However, the permeability decreases with time, dropping to about 3.4 × 10−5 m/min after 200 min of operation. Evidence was obtained showing that hydrolysis of CTA occurred, causing a dramatic decrease in the feed pH (protons transported from strip to feed solutions and a loss of extractant and plasticizer from the membrane, and then leading to the loss of indium permeability. To alleviate the problem of hydrolysis, we proposed an operation scheme called polymer inclusion membranes with strip dispersion: dispersing the strip solution in extractant-containing oil and then bringing the dispersion to contact with the polymer membrane. Since the strong acid was dispersed in oil, the membrane did not directly contact the strong acid at all times, and membrane hydrolysis was thus alleviated and the loss of indium permeability was effectively prevented. With the proposed scheme, a stable indium permeability of 2.5 × 10−4 m/min was obtained during the whole time period of the permeation experiment.

  5. Validity of HydraTrend reagent strips for the assessment of hydration status.

    Science.gov (United States)

    Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T

    2014-09-01

    Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.

  6. Significance of wave form parameters in stripping chronopotentiometric metal speciation analysis

    NARCIS (Netherlands)

    Town, R.M.; Leeuwen, van H.P.

    2002-01-01

    An analysis is presented of the significance of stripping chronopotentiometric (SCP) stripping peak parameters (peak potential, Ep, and peak half-width, w1/2) for determination of metal ion speciation. This study focuses on depletive SCP (low stripping current, I¿ constant), and considers the change

  7. Digital recording system

    International Nuclear Information System (INIS)

    Chandra, A.K.; Deshpande, S.V.; Iyer, A.; Vaidya, U.W.

    1987-01-01

    A large number of critical process parameters in nuclear power plants have hitherto been monitored using electromechanical chart recorders. The reducing costs of electronics systems have led to a trend towards modernizing power plant control rooms by computerizing all the panel instrumentation. As a first step, it has been decided to develop a digital recording system to record the values of 48 process parameters. The system as developed and described in this report is more than a replacement for recorders; it offers substantial advantages in terms of lower overall system cost, excellent time resolution, accurate data and absolute synchronization for correlated signals. The system provides high speed recording of 48 process parameters, maintains historical records and permits retrieval and display of archival information on a colour monitor, a plotter and a printer. It is implemented using a front end data acquisition unit connected on a serial link to a PC-XT computer with 20 MB Winchester. The system offers an extremely user friendly man machine interaction, based on a hierarchical paged menu driven scheme. Softwre development for this system has been carried out using the C language. (author). 9 figs

  8. Electrode/Dielectric Strip For High-Energy-Density Capacitor

    Science.gov (United States)

    Yen, Shiao-Ping S.

    1994-01-01

    Improved unitary electrode/dielectric strip serves as winding in high-energy-density capacitor in pulsed power supply. Offers combination of qualities essential for high energy density: high permittivity of dielectric layers, thinness, and high resistance to breakdown of dielectric at high electric fields. Capacitors with strip material not impregnated with liquid.

  9. Strip reduction testing of lubricants developed during ENFORM project

    DEFF Research Database (Denmark)

    Gazvoda, S.; Andreasen, Jan Lasson; Olsson, David Dam

    Strip reduction testing of lubricants developed during ENFORM project. Experiments were conducted with the strip reduction test [1] in order to classify experimental lubricants, developed during concerned project. One reference lubricant was used during testing....

  10. Micro-strip Metal Foil Detectors for the Beam Profile Monitoring

    CERN Document Server

    Pugatch, V M; Fedorovitch, O A; Mikhailenko, A V; Prystupa, S V; Pylypchenko, Y

    2005-01-01

    The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. Fast particles hitting a metal strip initiate Secondary Electron Emission (SEE) which occurs at 10 - 50 nm surface layers of a strip. The SEE yield is measured by a sensitive Charge Integrator with built-in current-to-frequency converter (1 Hz per 1 fA). The MMFD (deposited onto the 20 μm thick Si-wafer) with 32 Al strips (10 μm wide, 32 μm pitch) has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator for Single-Event-Upset studies of the BEETLE micro-chip. Similar MMFD (0.5 μm thick Ni-strips) with totally removed Si-wafer (by plasma-chemistry, at the working area of 8 x 10 mm2) has been applied for the on-line X-ray BPM at the HASYLAB (DESY). The number of photons (11.3 GeV, mean X-ray energy 18 keV) producing out of a strip a single SEE was evaluated as (1.5 ±0.5)* 104. MMFD has demonstrated stable...

  11. Removal of nitrogen from swine manure by ammonia stripping; Reduccion del contenido en nitrogeno amoniacal del purin procino mediante la tecnica de stripping

    Energy Technology Data Exchange (ETDEWEB)

    Hidalgo, M. D.; Alamo, J. del; Nunez, U.; Irusta, R. [Grupo de Tecnologia Ambiental . Laboratorio de Analisis y Estudios Medioambientales. Valladolid (Spain)

    2001-07-01

    Lab scale experiments were undertaken to investigate air stripping as method for removing ammonia from cattle effluents and, more concretely, from the liquid fraction of swine manure. The effects of packet size, influent pH, air to liquid flow ratio and liquid recirculation flow in the stripping tower were investigated. The high ammonia removal efficiency of the air stripping method indicates that it could provide an interim solution for current waste management problems in the swine industry. (Author) 5 refs.

  12. Application of CUSUM charts to detect lameness in a milking robot

    DEFF Research Database (Denmark)

    Pastell, Matti; Madsen, Henrik

    2008-01-01

    shown that the weight distribution between limbs changes when cow get lame. In this paper we suggest CUSUM charts to automatically detect lameness based on the measurements. CUSUM charts are statistical based control charts and are well suited for checking a measuring system in operation for any...

  13. Flexible strip supercapacitors for future energy storage

    OpenAIRE

    Zhang, R-R; Xu, Y-M; Harrison, D; Fyson, J; Qiu, F-L; Southee, D

    2015-01-01

    Flexible strip supercapacitors are developed and their electrochemical properties are characterized. Activated carbon is used as the electrode material and it is found to have a good porous structure which provides a large surface area for energy storage. Furthermore, this activated carbon performs well. The manufacturing processes for the supercapacitors are described in detail and the preparation process has good reproducibility. The strip supercapacitors are combined in series and parallel...

  14. The Usage of Time Series Control Charts for Financial Process Analysis

    Directory of Open Access Journals (Sweden)

    Kovářík Martin

    2012-09-01

    Full Text Available We will deal with financial proceedings of the company using methods of SPC (Statistical Process Control, specifically through time series control charts. The paper will outline the intersection of two disciplines which are econometrics and statistical process control. The theoretical part will discuss the methodology of time series control charts and in the research part there will be this methodology demonstrated in three case studies. The first study will focus on the regulation of simulated financial flows for a company by CUSUM control chart. The second study will involve the regulation of financial flows for a heteroskedastic financial process by EWMA control chart. The last case study of our paper will be devoted to applications of ARIMA, EWMA and CUSUM control charts in the financial data that are sensitive to the mean shifting while calculating the autocorrelation in the data. In this paper, we highlight the versatility of control charts not only in manufacturing but also in managing the financial stability of cash flows.

  15. Study the Z-Plane Strip Capacitance

    International Nuclear Information System (INIS)

    Parikh, H.; Swain, S.

    2005-01-01

    The BaBaR detector at the Stanford Linear Accelerator Center is currently undergoing an upgrade to improve its muon and neutral hadron detection system. The Resistive Plate Chambers (RPCs) that had been used till now have deteriorated in performance over the past few years and are being replaced by Limited Streamer Tube (LSTs). Each layer of the system consists of a set of up to 10 streamer tube modules which provide one coordinate (φ coordinate) and a single ''Z-plane'' which provides the Z coordinate of the hit. The large area Z-planes (up to 12m 2 ) are 1mm thick and contain 96 copper strips that detect the induced charge from avalanches created in the streamer tube wires. All the Z-planes needed for the upgrade have already been constructed, but only a third of the planes were installed last summer. After installing the 24 Z-planes last year, it was learned that 0.7% of the strips were dead when put inside the detector. This was mainly due to the delicate solder joint between the read-out cable and the strip, and since it is difficult to access or replace the Z-planes inside the detector, it is very important to perform various tests to make sure that the Z-planes will be efficient and effective in the long term. We measure the capacitance between the copper strips and the ground plane, and compare it to the theoretical value that we expect. Instead of measuring the capacitance channel by channel, which would be a very tedious job, we developed a more effective method of measuring the capacitance. Since all the Z-planes were built at SLAC, we also built a smaller 46 cm by 30 cm Z-plane with 12 strips just to see how they were constructed and to gain a better understanding about the solder joints

  16. High temperature oxidation of thin FeCrAl strips

    International Nuclear Information System (INIS)

    Andrieu, E.; Germidis, A.; Molins, R.

    1997-01-01

    This study concerns the oxidation behaviour between 850 and 1100 C of FeCrAl thin strips. Oxidation kinetics have been continuously recorded on a thermobalance as well as discontinuously in an ''industrial'' furnace. Detailed observations of oxide layers have been performed in transmission electron microscopy on oxidized thin foil cross-sections. Oxide morphologies are correlated with kinetics: Slow kinetics and columnar α alumina grains above 950 C, fast kinetics and transition alumina platelets (γ-alumina) at 850 C and 900 C, followed by small α-alumina grains formation underneath. The weight gains in the industrial furnace displayed significant scatter and were generally greater than those measured in the thermobalance. The effect of extrinsic factors such as specimen size and shape, atmosphere, air flow conditions on the early formation of transition aluminas explains the observed differences. It appears then that in given cases parabolic constant identification from TGA recordings is difficult, or even impossible. This might contribute to explain the differences in the results presented in the literature. (orig.)

  17. Blinded with Science or Informed by Charts? A Replication Study

    OpenAIRE

    Dragicevic , Pierre; Jansen , Yvonne

    2018-01-01

    International audience; We provide a reappraisal of Tal and Wansink's study "Blinded with Science" , where seemingly trivial charts were shown to increase belief in drug efficacy, presumably because charts are associated with science. Through a series of four replications conducted on two crowdsourcing platforms, we investigate an alternative explanation, namely, that the charts allowed participants to better assess the drug's efficacy. Considered together, our experiments suggest that the ch...

  18. Effects of hydrostatic strain on eigenstates of Möbius strips

    DEFF Research Database (Denmark)

    Lassen, Benny; Willatzen, Morten; Gravesen, Jens

    2011-01-01

    In this paper we theoretically investigate the allowed energies and associate wave-functions for Möbius strips with varying thicknesses. We show that the induced strain in fabricating these Möbius strips will have an pronounced impact on the energies and wave-functions for thick strips, while f...... for thin strips the impact of strain is negligible. We furthermore, show that a simpler strain free approximate theory base on differential geometry is in excellent agreement with detailed finite element calculations. © 2011 IEEE....

  19. Inland Electronic Navigational Charts (IENC)

    Data.gov (United States)

    Army Corps of Engineers, Department of the Army, Department of Defense — These Inland Electronic Navigational Charts (IENCs) were developed from available data used in maintenance of Navigation channels. Users of these IENCs should be...

  20. NOAA Electronic Navigational Charts (ENC)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Office of Coast Survey (OCS) has been involved in the development of a NOAA Electronic Navigational Chart (NOAA ENC) suite to support the marine transportation...

  1. Low-resistance strip sensors for beam-loss event protection

    International Nuclear Information System (INIS)

    Ullán, M.; Benítez, V.; Quirion, D.; Zabala, M.; Pellegrini, G.; Lozano, M.; Lacasta, C.; Soldevila, U.; García, C.; Fadeyev, V.; Wortman, J.; DeFilippis, J.; Shumko, M.; Grillo, A.A; Sadrozinski, H.F.-W.

    2014-01-01

    AC-coupled silicon strip sensors can be damaged in case of a beam loss due to the possibility of a large charge accumulation in the bulk, developing very high voltages across the coupling capacitors which can destroy them. Punch-through structures are currently used to avoid this problem helping to evacuate the accumulated charge as large voltages are developing. Nevertheless, previous experiments, performed with laser pulses, have shown that these structures can become ineffective in relatively long strips. The large value of the implant resistance can effectively isolate the “far” end of the strip from the punch-through structure leading to large voltages. We present here our developments to fabricate low-resistance strip sensors to avoid this problem. The deposition of a conducting material in contact with the implants drastically reduces the strip resistance, assuring the effectiveness of the punch-through structures. First devices have been fabricated with this new technology. Initial results with laser tests show the expected reduction in peak voltages on the low resistivity implants. Other aspects of the sensor performance, including the signal formation, are not affected by the new technology

  2. US Nuclear Regulatory Commission organization charts and functional statements

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    This document is the US NRC organizational structure and chart as of July 1, 1996. It contains the org charts for the Commission, ACRS, ASLAB, Commission staff offices, Executive Director for Operations, Office of the Inspector General, Program offices, and regional offices.

  3. US Nuclear Regulatory Commission organization charts and functional statements

    International Nuclear Information System (INIS)

    1996-01-01

    This document is the US NRC organizational structure and chart as of July 1, 1996. It contains the org charts for the Commission, ACRS, ASLAB, Commission staff offices, Executive Director for Operations, Office of the Inspector General, Program offices, and regional offices

  4. System Behaviour Charts Inform an Understanding of Biodiversity Recovery

    Directory of Open Access Journals (Sweden)

    Simon A. Black

    2015-01-01

    Full Text Available Practitioners working with species and ecosystem recovery typically deal with the complexity of, on one hand, lack of data or data uncertainties and, on the other hand, demand for critical decision-making and intervention. The control chart methods of commercial and industrial and environmental monitoring can complement an ecological understanding of wildlife systems including those situations which incorporate human activities and land use. Systems Behaviour Charts are based upon well-established control chart methods to provide conservation managers with an approach to using existing data and enable insight to aid timely planning of conservation interventions and also complement and stimulate research into wider scientific and ecological questions. When the approach is applied to existing data sets in well-known wildlife conservation cases, the subsequent Systems Behaviour Charts and associated analytical criteria demonstrate insights which would be helpful in averting problems associated with each case example.

  5. Metal films with imprinted nanostructures by template stripping

    DEFF Research Database (Denmark)

    Eriksen, René Lynge; Pors, Anders; Dreier, Jes

    We present a novel template stripping procedure for fabricating metal films with imprinted nanostructures. The basic idea is to deposit a gold film onto a nano-structured substrate and subsequently strip the film from the substrate surface thereby revealing imprinted nanostructures in the film...... result is a thin gold film with imprinted nano-cavities....

  6. Liquidity, Reconstitution, and the Value of U.S. Treasury Strips.

    OpenAIRE

    Daves, Phillip R; Ehrhardt, Michael C

    1993-01-01

    An apparent pricing anomaly exists in the market for U.S. Treasury strips: zero-coupon strips created from principal payments typically trade at significantly higher prices than otherwi se identical zero-coupon strips created from coupon payments. In additi on to documenting this phenomenon, this study demonstrates that differences in liquidity and differences in reconstitution characteristics explain much of this price variation. Copyright 1993 by American Finance Association.

  7. Detecting SYN flood attacks via statistical monitoring charts: A comparative study

    KAUST Repository

    Bouyeddou, Benamar

    2017-12-14

    Accurate detection of cyber-attacks plays a central role in safeguarding computer networks and information systems. This paper addresses the problem of detecting SYN flood attacks, which are the most popular Denial of Service (DoS) attacks. Here, we compare the detection capacity of three commonly monitoring charts namely, a Shewhart chart, a Cumulative Sum (CUSUM) control chart and exponentially weighted moving average (EWMA) chart, in detecting SYN flood attacks. The comparison study is conducted using the publicly available benchmark datasets: the 1999 DARPA Intrusion Detection Evaluation Datasets.

  8. Deuteron stripping reactions with Tabakin potential

    International Nuclear Information System (INIS)

    Osman, A.

    1976-05-01

    Deuteron stripping reactions are considered. Due to the strong repulsion between nucleons at very short distances, we have investigated the nuclear short-range correlations. The neutron proton nuclear potential in the deuteron is taken as a short-range repulsive core surrounded by a long-range attractive potential. The neutron-proton potential is taken as the Tabakin separable potential to take into account the short-range correlations. The differential cross-sections for deuteron stripping reactions have been calculated in two different cases by taking Yamaguchi or Breit et al type parameters for the Tabakin potential used. The angular distributions for different (d,p) stripping reactions on the different target nuclei 28 Si, 32 , 34 S, 36 Ar, 40 , 48 Ca, 50 , 52 , 54 Cr have been calculated using the DWBA calculations. Our present theoretical calculations for the angular distributions of the different reactions cosidered have been fitted to the experimental data, where good agreement is obtained. The extracted spectroscopic factors from the present work are found to be more reliable

  9. Precipitation stripping of neodymium from carboxylate extractant with aqueous oxalic acid solutions

    International Nuclear Information System (INIS)

    Konishi, Yasuhiro; Asai, Satoru; Murai, Tetuya

    1993-01-01

    This paper describes a precipitation stripping method in which neodymium ions are stripped from carboxylate extractant in organic solvent and simultaneously precipitated with aqueous oxalic acid solution. For the single-stage process, a quantitative criterion for precipitating oxalate powders was derived theoretically, and stripping experiments were done under the precipitation conditions. The resultant precipitates were neodymium oxalate, which is completely free from contamination by the carboxylate extractant and the organic solvent. The overall rate of stripping was controlled by the transfer of neodymium carboxylate in the organic solution, indicating that the presence of oxalic acid in the aqueous phase has no effect on the stripping rate. These findings demonstrate the feasibility of combining the conventional stripping and precipitation stages in a solvent extraction process for separation and purification of rare earths

  10. The use of principal components and univariate charts to control multivariate processes

    Directory of Open Access Journals (Sweden)

    Marcela A. G. Machado

    2008-04-01

    Full Text Available In this article, we evaluate the performance of the T² chart based on the principal components (PC X chart and the simultaneous univariate control charts based on the original variables (SU charts or based on the principal components (SUPC charts. The main reason to consider the PC chart lies on the dimensionality reduction. However, depending on the disturbance and on the way the original variables are related, the chart is very slow in signaling, except when all variables are negatively correlated and the principal component is wisely selected. Comparing the SU , the SUPC and the T² charts we conclude that the SU X charts (SUPC charts have a better overall performance when the variables are positively (negatively correlated. We also develop the expression to obtain the power of two S² charts designed for monitoring the covariance matrix. These joint S² charts are, in the majority of the cases, more efficient than the generalized variance chart.Neste artigo, avaliamos o desempenho do gráfico de T² baseado em componentes principais (gráfico PC e dos gráficos de controle simultâneos univariados baseados nas variáveis originais (gráfico SU X ou baseados em componentes principais (gráfico SUPC. A principal razão para o uso do gráfico PC é a redução de dimensionalidade. Entretanto, dependendo da perturbação e da correlação entre as variáveis originais, o gráfico é lento em sinalizar, exceto quando todas as variáveis são negativamente correlacionadas e a componente principal é adequadamente escolhida. Comparando os gráficos SU X, SUPC e T² concluímos que o gráfico SU X (gráfico SUPC tem um melhor desempenho global quando as variáveis são positivamente (negativamente correlacionadas. Desenvolvemos também uma expressão para obter o poder de detecção de dois gráficos de S² projetados para controlar a matriz de covariâncias. Os gráficos conjuntos de S² são, na maioria dos casos, mais eficientes que o gr

  11. Gulf of Mexico IFR Aeronautical Chart Index - Aeronautical Information Services Digital Products

    Data.gov (United States)

    Department of Transportation — The IFR Enroute Aeronautical Chart series is designed to meet the needs of users who require a digital version chart. This is the visual index to the charts for the...

  12. Proposed colour banded early warning observation charts for South ...

    African Journals Online (AJOL)

    Introduction of a colour banded observation chart should be combined with a clear communication strategy. The process should be used to change the organisational culture to be more proactive in initiating early intervention to reduce the burden of unintended complications. Keywords: Observation chart; Physiology; ...

  13. SpeckTackle: JavaScript charts for spectroscopy.

    Science.gov (United States)

    Beisken, Stephan; Conesa, Pablo; Haug, Kenneth; Salek, Reza M; Steinbeck, Christoph

    2015-01-01

    Spectra visualisation from methods such as mass spectroscopy, infrared spectroscopy or nuclear magnetic resonance is an essential part of every web-facing spectral resource. The development of an intuitive and versatile visualisation tool is a time- and resource-intensive task, however, most databases use their own embedded viewers and new databases continue to develop their own viewers. We present SpeckTackle, a custom-tailored JavaScript charting library for spectroscopy in life sciences. SpeckTackle is cross-browser compatible and easy to integrate into existing resources, as we demonstrate for the MetaboLights database. Its default chart types cover common visualisation tasks following the de facto 'look and feel' standards for spectra visualisation. SpeckTackle is released under GNU LGPL to encourage uptake and reuse within the community. The latest version of the library including examples and documentation on how to use and extend the library with additional chart types is available online in its public repository.

  14. Computer programs to make a Chart of the nuclides for WWW

    International Nuclear Information System (INIS)

    Nakagawa, Tsuneo; Katakura, Jun-ichi; Horiguchi, Takayoshi

    1999-06-01

    Computer programs to make a chart of the nuclides for World Wide Web (WWW) have been developed. The programs make a data file for WWW chart of the nuclides from a data file containing nuclide information in the format similar to ENSDF, by filling unknown half-lives with calculated ones. Then, the WWW chart of the nuclides in the gif format is created from the data file. The programs to make html files and image map files, to select a chart of selected nuclides, and to show various information of nuclides are included in the system. All the programs are written in C language. This report describes the formats of files, the programs and 1998 issue of Chart of the Nuclides made by means of the present programs. (author)

  15. Constructing an exposure chart: step by step (based on standard procedures)

    International Nuclear Information System (INIS)

    David, Jocelyn L; Cansino, Percedita T.; Taguibao, Angileo P.

    2000-01-01

    An exposure chart is very important in conducting radiographic inspection of materials. By using an accurate exposure chart, an inspector is able to avoid a trial and error way of determining correct time to expose a specimen, thereby producing a radiograph that has an acceptable density based on a standard. The chart gives the following information: x-ray machine model and brand, distance of the x-ray tube from the film, type and thickness of intensifying screens, film type, radiograph density, and film processing conditions. The methods of preparing an exposure chart are available in existing radiographic testing manuals. These described methods are presented in step by step procedures, covering the actual laboratory set-up, data gathering, computations, and transformation of derived data into Characteristic Curve and Exposure Chart

  16. Growth charts for children with Ellis–van Creveld syndrome

    Science.gov (United States)

    Eilers, Paul H. C.; Lawrence, Kate; Hennekam, Raoul C. M.; Versteegh, Florens G. A.

    2010-01-01

    Ellis–van Creveld (EvC) syndrome is a congenital malformation syndrome with marked growth retardation. In this study, specific growth charts for EvC patients were derived to allow better follow-up of growth and earlier detection of growth patterns unusual for EvC. With the use of 235 observations of 101 EvC patients (49 males, 52 females), growth charts for males and females from 0 to 20 years of age were derived. Longitudinal and cross-sectional data were collected from an earlier review of growth data in EvC, a database of EvC patients, and from recent literature. To model the growth charts, the GAMLSS package for the R statistical program was used. Height of EvC patients was compared to healthy children using Dutch growth charts. Data are presented both on a scale for age and on a scale for the square root of age. Compared to healthy Dutch children, mean height standard deviation score values for male and female EvC patients were −3.1 and −3.0, respectively. The present growth charts should be useful in the follow-up of EvC patients. Most importantly, early detection of growth hormone deficiency, known to occur in EvC, will be facilitated. PMID:20830486

  17. Growth charts for children with Ellis-van Creveld syndrome.

    Science.gov (United States)

    Verbeek, Sabine; Eilers, Paul H C; Lawrence, Kate; Hennekam, Raoul C M; Versteegh, Florens G A

    2011-02-01

    Ellis-van Creveld (EvC) syndrome is a congenital malformation syndrome with marked growth retardation. In this study, specific growth charts for EvC patients were derived to allow better follow-up of growth and earlier detection of growth patterns unusual for EvC. With the use of 235 observations of 101 EvC patients (49 males, 52 females), growth charts for males and females from 0 to 20 years of age were derived. Longitudinal and cross-sectional data were collected from an earlier review of growth data in EvC, a database of EvC patients, and from recent literature. To model the growth charts, the GAMLSS package for the R statistical program was used. Height of EvC patients was compared to healthy children using Dutch growth charts. Data are presented both on a scale for age and on a scale for the square root of age. Compared to healthy Dutch children, mean height standard deviation score values for male and female EvC patients were -3.1 and -3.0, respectively. The present growth charts should be useful in the follow-up of EvC patients. Most importantly, early detection of growth hormone deficiency, known to occur in EvC, will be facilitated.

  18. Reforestation of strip-mined lands in West Virginia

    Science.gov (United States)

    H. Spencer Potter; Sidney Weitzman; George R., Jr. Trimble

    1951-01-01

    The early 1940's witnessed a striking increase in strip-mining throughout the eastern coal region. West Virginia, with its extensive coal resources, naturally was caught in the full current of this shift in mining methods. Today the raw gash on the hillside - almost infallibly the mark of a strip-mine operation - is a familiar sight in the State.

  19. Stripping foils for the PSB H- injection system

    CERN Document Server

    Aiba, M; Goddard, B; Weterings, W

    2009-01-01

    Beam physics considerations for the stripping foil of the PSB H- injection system are described, including the arguments for the foil type, thickness, geometry and positioning. The foil performance considerations are described, including expected stripping efficiency, emittance growth, energy straggling, temperature and lifetime. The required movement ranges and tolerances are detailed, together with the assumptions used.

  20. Quality Tests of Double-Sided Silicon Strip Detectors

    CERN Document Server

    Cambon, T; CERN. Geneva; Fintz, P; Guillaume, G; Jundt, F; Kuhn, C; Lutz, Jean Robert; Pagès, P; Pozdniakov, S; Rami, F; Sparavec, K; Dulinski, W; Arnold, L

    1997-01-01

    The quality of the SiO2 insulator (AC coupling between metal and implanted strips) of double-sided Silicon strip detectors has been studied by using a probe station. Some tests performed on 23 wafers are described and the results are discussed. Remark This note seems to cause problems with ghostview but it can be printed without any problem.

  1. Evaluation of a portable urinary pH meter and reagent strips.

    Science.gov (United States)

    De Coninck, Vincent; Keller, Etienne Xavier; Rodríguez-Monsalve, María; Haymann, Jean-Philippe; Doizi, Steeve; Traxer, Olivier

    2018-04-27

    To evaluate a portable electronic pH meter and to put its accuracy in perspective with reagent strips read by a layperson, a healthcare professional and an electronic reading device. Based on a pre-analysis on 20 patients, a sample size of 77 urine aliquots from healthy volunteers was necessary to obtain sufficient study power. Measurements of urinary pH were obtained by use of reagent strips, a portable pH meter and a laboratory pH meter (gold standard). Reagents strips were read by a professional experienced in interpreting strips, a layperson, and an electronic strip reader. The mean matched pair difference between measurement methods was analyzed by the paired t-test. The degree of correlation and agreement were evaluated by the Pearson's correlation coefficient and Bland-Altman plots, respectively. The mean matched pair difference between the gold standard and all other pH measurement methods was the smallest with the portable electronic pH meter (bias 0.01, 95% CI -0.07 to 0.08; p=0.89), followed by strips read by a professional (bias -0.09, 95% CI -0.21 to 0.02; p=0.10), layperson (bias -0.17, 95% CI -0.31 to -0.04; p=0.015) and electronic strip reader (bias -0.29, 95% CI -0.41 to -0.16; pmeter achieved the highest Pearson's correlation coefficient and narrowest 95% limits of agreement, followed by strip interpretation by a professional, the electronic strip reader and the layperson. In order to quantify the ability of pH measurement methods to correctly classify values within a predefined urinary pH target range, we performed classification tests for several stones. The portable electronic pH meter outperformed all other measurement methods for negative predictive values. Findings of the current study support that the portable electronic pH meter is a reliable pH measuring device. It seems to be more accurate compared to reagent strips readings.

  2. A new strips tracker for the upgraded ATLAS ITk detector

    Science.gov (United States)

    David, C.

    2018-01-01

    The ATLAS detector has been designed and developed to function in the environment of the present Large Hadron Collider (LHC). At the next-generation tracking detector proposed for the High Luminosity LHC (HL-LHC), the so-called ATLAS Phase-II Upgrade, the fluences and radiation levels will be higher by as much as a factor of ten. The new sub-detectors must thus be faster, of larger area, more segmented and more radiation hard while the amount of inactive material should be minimized and the power supply to the front-end systems should be increased. For those reasons, the current inner tracker of the ATLAS detector will be fully replaced by an all-silicon tracking system that consists of a pixel detector at small radius close to the beam line and a large area strip tracker surrounding it. This document gives an overview of the design of the strip inner tracker (Strip ITk) and summarises the intensive R&D activities performed over the last years by the numerous institutes within the Strips ITk collaboration. These studies are accompanied with a strong prototyping effort to contribute to the optimisation of the Strip ITk's structure and components. This effort culminated recently in the release of the ATLAS Strips ITk Technical Design Report (TDR).

  3. Comparison of blood glucose test strips in the detection of neonatal hypoglycaemia

    OpenAIRE

    Wilkins, B H; Kalra, D

    1982-01-01

    Blood glucose levels were estimated in 101 neonatal blood samples using three glucose test strip methods and the results compared with those from a laboratory. BM-test-glycemie 20-800 test strips and Reflotest-hypoglycemie test strips gave a rapid and reliable estimate of blood glucose level in the range 0-8 mmol/l (0-140 mg/100 ml). Dextrostix test strips tended to overestimate all blood glucose levels.

  4. Buffers and vegetative filter strips

    Science.gov (United States)

    Matthew J. Helmers; Thomas M. Isenhart; Michael G. Dosskey; Seth M. Dabney

    2008-01-01

    This chapter describes the use of buffers and vegetative filter strips relative to water quality. In particular, we primarily discuss the herbaceous components of the following NRCS Conservation Practice Standards.

  5. Control charts for location based on different sampling schemes

    NARCIS (Netherlands)

    Mehmood, R.; Riaz, M.; Does, R.J.M.M.

    2013-01-01

    Control charts are the most important statistical process control tool for monitoring variations in a process. A number of articles are available in the literature for the X̄ control chart based on simple random sampling, ranked set sampling, median-ranked set sampling (MRSS), extreme-ranked set

  6. The depletion properties of silicon microstrip detectors with variable strip pitch

    International Nuclear Information System (INIS)

    Krizmanic, J.F.

    1994-01-01

    We have investigated the depletion properties of trapezoidal shaped silicon microstrip detectors which have variable strip pitch. Four types of detectors were examined: three detectors have constant strip width and a fourth has a varying strip width. The detectors are single sided with readout performed via p + strips. The depletion properties of the devices were measured using two different methods. The first used capacitance versus voltage measurements, while the second used a 1060 nm wavelength laser coupled to a single mode fiber with a mode field diameter less than 10 μm. The small laser spot size allowed for the depletion depth to be measured in a localized area of the detector. The laser induced charge on an electrode was measured as a function of reverse bias voltage using a sensitive charge preamplifier. The depletion voltages of the detectors demonstrate a strong dependence upon the ratio of strip width to strip pitch. Moreover, these measurements show that a large value of this ratio yields a lower depletion voltage and vice versa. (orig.)

  7. A GEM readout with radial zigzag strips and linear charge-sharing response

    Science.gov (United States)

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak; Purschke, Martin L.; Woody, Craig

    2018-04-01

    We study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures are implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Angular resolutions of 60-84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.

  8. Three-Dimensional Nuclear Chart--Understanding Nuclear Physics and Nucleosynthesis in Stars

    Science.gov (United States)

    Koura, Hiroyuki

    2014-01-01

    Three-dimensional (3D) nuclear charts were created using toy blocks, which represent the atomic masses per nucleon number and the total half-lives for each nucleus in the entire region of the nuclear mass. The bulk properties of the nuclei can be easily understood by using these charts. Subsequently, these charts were used in outreach activities…

  9. Sediment removal by prairie filter strips in row-cropped ephemeral watersheds

    Science.gov (United States)

    Matthew J. Helmers; Xiaobo Zhou; Heidi Asbjornsen; Randy Kolka; Mark D. Tomer; Richard M. Cruse

    2012-01-01

    Twelve small watersheds in central Iowa were used to evaluate the eff ectiveness of prairie filter strips (PFS) in trapping sediment from agricultural runoff. Four treatments with PFS of different size and location (100% rowcrop, 10% PFS of total watershed area at footslope, 10% PFS at footslope and in contour strips, 20% PFS at footslope and in contour strips)...

  10. 14 CFR Section 3 - Chart of Balance Sheet Accounts

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Chart of Balance Sheet Accounts Section 3 Section 3 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION... Balance Sheet Classifications Section 3 Chart of Balance Sheet Accounts [See footnotes at end of table...

  11. CHART in lung cancer: Economic evaluation and incentives for implementation

    International Nuclear Information System (INIS)

    Lievens, Yolande; Kesteloot, Katrien; Bogaert, Walter van den

    2005-01-01

    Background and purpose: To investigate the financial consequences and the impact on daily implementation of CHART in lung cancer. Patients and methods: A cost-effectiveness and cost-utility analysis were performed using Markov models, comparing the early and delayed costs and effects of CHART for NSCLC over a 4-year time span from a societal viewpoint. The outcome estimates were based on the CHART literature, the cost estimates on the standard practice of the Leuven University Hospitals, the radiotherapy costs being derived from an activity-based costing (ABC) programme developed in the department. Results: The additional societal cost per life-year gained was EURO 9164, the incremental cost per quality-adjusted life-year EURO 11,576. Sensitivity analyses confirmed the robustness of these results, the incremental cost-utility ratio remaining well under 20,000 EURO /QALY in all tested circumstances. The threshold analyses found the results of the study to be sensitive to the cost of CHART and to the quality of life after treatment. More specifically, standard treatment would become the optimal treatment if CHART would have a higher cost or would result in more long-term side effects. Conclusion: CHART should not be denied to patients with NSCLC on the basis of clinical or economic arguments. Other factors such as socio-economical, institutional, practical departmental and physician-bound barriers most probably explain the lack of implementation into daily practice

  12. Concordance of self-reported and medical chart information on cancer diagnosis and treatment

    Directory of Open Access Journals (Sweden)

    Shu Xiao Ou

    2011-05-01

    Full Text Available Abstract Background Self-reported information is an important tool for collecting clinical information for epidemiologic studies and in clinical settings where electronic medical records are not employed and shared. Methods Using data collected from the Shanghai Breast Cancer Survival Study (SBCSS, a population-based, prospective cohort study of 5,042 women diagnosed with breast cancer in Shanghai, China, we compared the concordance of patient questionnaire responses to a survey administered approximately 6 months after cancer diagnosis with medical chart information obtained from the diagnostic hospitals for several disease and treatment-related variables. Results Of 5,042 SBCSS participants, medical chart information was available for 4,948 women (98.1%. Concordance between patient self-reported and medical chart information was high for the majority of disease-related variables, including: diagnosing hospital (agreement: 98.7%, kappa: 0.99, type of surgery conducted (94.0%, 0.53, ER/PR status (94.5%, 0.91, and tumor position (98.2%, 0.97, as well as for important calendar dates, such as date of diagnosis, surgery, and first chemotherapy treatment. The 10 most commonly used chemotherapeutic drugs were all reported with agreement rates of at least 82%, with associated kappa values that ranged from 0.41 for calcium folinate to 0.76 for vinorelbine. Conclusions Our study found high validity for patient self-reported information for a variety of disease and treatment-related variables, suggesting the utility of self-reports as an important source of clinical information for both epidemiological research and patient care.

  13. Toward developing a standardized Arabic continuous text reading chart.

    Science.gov (United States)

    Alabdulkader, Balsam; Leat, Susan Jennifer

    Near visual acuity is an essential measurement during an oculo-visual assessment. Short duration continuous text reading charts measure reading acuity and other aspects of reading performance. There is no standardized version of such chart in Arabic. The aim of this study is to create sentences of equal readability to use in the development of a standardized Arabic continuous text reading chart. Initially, 109 Arabic pairs of sentences were created for use in constructing a chart with similar layout to the Colenbrander chart. They were created to have the same grade level of difficulty and physical length. Fifty-three adults and sixteen children were recruited to validate the sentences. Reading speed in correct words per minute (CWPM) and standard length words per minute (SLWPM) was measured and errors were counted. Criteria based on reading speed and errors made in each sentence pair were used to exclude sentence pairs with more outlying characteristics, and to select the final group of sentence pairs. Forty-five sentence pairs were selected according to the elimination criteria. For adults, the average reading speed for the final sentences was 166 CWPM and 187 SLWPM and the average number of errors per sentence pair was 0.21. Childrens' average reading speed for the final group of sentences was 61 CWPM and 72 SLWPM. Their average error rate was 1.71. The reliability analysis showed that the final 45 sentence pairs are highly comparable. They will be used in constructing an Arabic short duration continuous text reading chart. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  14. Efficiency measurements for 3D silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parzefall, Ulrich, E-mail: ulrich.parzefall@physik.uni-freiburg.d [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Dalla Betta, Gian-Franco [INFN Trento and Universita di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Boscardin, Maurizio [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Eckert, Simon [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Eklund, Lars; Fleta, Celeste [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Jakobs, Karl; Koehler, Michael; Kuehn, Susanne; Pahn, Gregor [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Parkes, Chris; Pennicard, David [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Ronchin, Sabina [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Zoboli, Andrea [INFN Trento and Universita di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Zorzi, Nicola [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy)

    2010-11-01

    Silicon strip detectors are widely used as part of the inner tracking layers in particle physics experiments. For applications at the luminosity upgrade of the Large Hadron Collider (LHC), the sLHC, silicon detectors with extreme radiation hardness are required. The 3D detector design, where electrodes are processed from underneath the strips into the silicon bulk material, provides a way to enhance the radiation tolerance of standard planar silicon strip detectors. Detectors with several innovative 3D designs that constitute a simpler and more cost-effective processing than the 3D design initially proposed were connected to read-out electronics from LHC experiments and subsequently tested. Results on the amount of charge collected, the noise and the uniformity of charge collection are given.

  15. Borehole DC-12 hydrostratigraphic chart

    International Nuclear Information System (INIS)

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart identifies the basic stratigraphy and preliminary hydrologic testing results for Borehole DC-12. This borehole was cored through the Saddle Mountains and Wanapum basalt formations and into the Grande Ronde. Selected zones were hydrologically tested during coring

  16. Borehole DC-14 hydrostratigraphic chart

    International Nuclear Information System (INIS)

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart identifies the basic stratigraphy and preliminary hydrologic testing results for Borehole DC-14. This borehole was cored through the Saddle Mountains and Wanapum basalt formations and into the Grande Ronde. Selected zones were hydrologically tested during coring

  17. Borehole DC-15 hydrostratigraphic chart

    International Nuclear Information System (INIS)

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart identifies the basic stratigraphy and preliminary hydrologic testing results for Borehole DC-15. This borehole was cored through the Saddle Mountains and Wanapum basalt formations and into the Grande Ronde. Selected zones were hydrologically tested during coring

  18. First results from a silicon-strip detector with VLSI readout

    International Nuclear Information System (INIS)

    Anzivino, G.; Horisberger, R.; Hubbeling, L.; Hyams, B.; Parker, S.; Breakstone, A.; Litke, A.M.; Walker, J.T.; Bingefors, N.

    1986-01-01

    A 256-strip silicon detector with 25 μm strip pitch, connected to two 128-channel NMOS VLSI chips (Microplex), has been tested using straight-through tracks from a ruthenium beta source. The readout channels have a pitch of 47.5 μm. A single multiplexed output provides voltages proportional to the integrated charge from each strip. The most probable signal height from the beta traversals is approximately 14 times the rms noise in any single channel. (orig.)

  19. KRITIK SOSIAL DALAM KOMIK STRIP PAK BEI

    Directory of Open Access Journals (Sweden)

    Yudhi Novriansyah

    2016-08-01

    Full Text Available This research aimed to do interpret the marking which flange social criticism and know laboring ideology in story of Comic Strip Pak Bei. Research based on theory of structural semiotic according to Ferdinand De Saussure. Using analysis of Syntagmatic as first level of meaning to the text network and also picture, and analysis of Paradigmatic as second level of meaning or implicit meaning (connota-tion, myth, ideology Analysis done to six Comic choice edition of Strip Pak Bei period of November 2004 - Februari 2005 which tend to flange social criticism. At band of syntagmatic, result of research indicate that story theme lifted from social problems that happened in major society. The fact clear progressively when connected by Intertextual with information and texts which have preexisted. At band of Paradigmatic, social criticism tend to emerge dimly, is not transparent. Because of Comic Strip Pak Bei expand in the middle of Java cultural domination that developing myth of criticize as action menacing compatibility and orderliness of society. Story of Comic Strip Pak Bei also confirm dominant ideology in Java society culture, namely ideology of Patriarkhi and Feudalism which still go into effect until now. This prove ideology idea according to Louis Althusser which not again opposition between class, but have been owned and practiced by all social class.

  20. Establishment of Electronic Chart-based Stroke Registry System in a Medical System in Taiwan

    Directory of Open Access Journals (Sweden)

    Tsong-Hai Lee

    2011-08-01

    Full Text Available To establish a prospective, real-time, self-sustainable stroke registry system, we incorporated a registry with an electronic chart to create an electronic chart-based stroke registry system in November 2006. The International Classification of Diseases Ninth Revision code (430–437 was used to auto-enroll stroke patients admitted to neurology departments. Clinical information was written by doctors, nursing information was recorded by nurses, and basic patient information was entered by administrative departments. Numerical data and the date and time of any studies were auto-downloaded from the hospital computer. In total, 212 items were auto-downloaded, including basic patient information, laboratory blood test and examination results, and the date and time of imaging and special intervention. The stroke scales (121 items, National Institutes of Health Stroke Scale, Barthel index, and modified Rankin scale were designed to be auto-adjusted to reduce incompatibility. The 95 items with pull-down options were used to specify the contents. This registry system can be time-, labor- and money-saving with secured data accuracy.

  1. Subtle Nonlinearity in Popular Album Charts

    Science.gov (United States)

    Bentley, R. Alexander; Maschner, Herbert D. G.

    Large-scale patterns of culture change may be explained by models of self organized criticality, or alternatively, by multiplicative processes. We speculate that popular album activity may be similar to critical models of extinction in that interconnected agents compete to survive within a limited space. Here we investigate whether popular music albums as listed on popular album charts display evidence of self-organized criticality, including a self-affine time series of activity and power-law distributions of lifetimes and exit activity in the chart. We find it difficult to distinguish between multiplicative growth and critical model hypotheses for these data. However, aspects of criticality may be masked by the selective sampling that a "Top 200" listing necessarily implies.

  2. Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors

    CERN Document Server

    Losel, Philipp Jonathan; The ATLAS collaboration

    2015-01-01

    Resisitve strip Micromegas detectors behave discharge tolerant. They have been tested extensively as smaller detectors of about 10 x 10 cm$^2$ in size and they work reliably at high rates of 100\\,kHz/cm$^2$ and above. Tracking resolutions well below 100\\,$\\mu$m have been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3\\,m$^2$ in size. To investigate possible differences between small and large detectors, a 1\\,m$^2$ detector with 2048 resistive strips at a pitch of 450 $\\mu$m was studied in the LMU Cosmic Ray Facility (CRF) using two 4 $\\times$ 2.2 m$^2$ large Monitored Drift Tube (MDT) chambers for cosmic muon reference tracking. Segmentation of the resistive strip anode plane in 57.6\\,mm x 95\\,mm large areas has been realized by the readout of 128 strips with one APV25 chip each and by 11 95\\,mm broad trigger scintillators placed along the readout strips.\\\\ This allows for mapping of homogenity in pulse height and efficiency, deter...

  3. Humor in elementary science: Development and evaluation of comic strips about sound

    Directory of Open Access Journals (Sweden)

    Ertuğrul Özdemir

    2017-06-01

    Full Text Available Comic strips on newspapers, magazines and Internet are one of the most accessible materials that may be used in science classroom as instructional tool. However, it is sometimes difficult to find and adapt appropriate comic strips useful for instructional purposes, because most of them are irrelevant. The purpose of this study is to develop and evaluate instructional comic strips aiming to contribute learning about sound related concepts. In this study, a series of instructional comic strips were created and implemented to a group of seventh grade students. Students’ responses to a number of open-ended questions were evaluated through qualitative content analysis. According to results, most of the students believed that comic strips help learning through simplifying science concepts and making retention of them easier. In addition, comic strips seemed to contribute students’ enjoyment toward science and perception of success in science.

  4. Performance of a new test strip for freestyle blood glucose monitoring systems.

    Science.gov (United States)

    Lock, John Paul; Brazg, Ronald; Bernstein, Robert M; Taylor, Elizabeth; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Chen, Ting; Welsh, Zoë; Amor, Walter; Bhogal, Claire; Ng, Ronald

    2011-01-01

    a new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. for glucose concentrations blood glucose results obtained by lay users fell within ± 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations ≥75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within  ±  5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.

  5. A design aid for sizing filter strips using buffer area ratio

    Science.gov (United States)

    M.G. Dosskey; M.J. Helmers; D.E. Eisenhauer

    2011-01-01

    Nonuniform field runoff can reduce the effectiveness of filter strips that are a uniform size along a field margin. Effectiveness can be improved by placing more filter strip where the runoff load is greater and less where the load is smaller. A modeling analysis was conducted of the relationship between pollutant trapping efficiency and the ratio of filter strip area...

  6. [Management of dental records: an example of the Department of Restorative Dentistry of the School of Odonto-Stomatology in Abidjan].

    Science.gov (United States)

    Assoumou, N M; Gnagne-Agnéro Koffi, N D Y; Avoaka Boni, M C; Adou, J; Adiko, E F

    2002-06-01

    The patient's file is often mismanaged because of the crowd and the frequency of emergencies caused by pain. The practitioner is worrying about handling it in first place. The objective of this work is to recall the importance of a good management of the dental records and to suggest a charting system. The interest of the dental chart, fundamental part of the patient dental file, is described before developing the implications related to an adequate management. The charting system of the service of Operative Dentistry and Endodontics of Abidjan Dental school is described. It translates the target of a good dental records management, which presents appreciable assets for practitioner, patient and administration.

  7. Monitoring Poisson observations using combined applications of Shewhart and EWMA charts

    Science.gov (United States)

    Abujiya, Mu'azu Ramat

    2017-11-01

    The Shewhart and exponentially weighted moving average (EWMA) charts for nonconformities are the most widely used procedures of choice for monitoring Poisson observations in modern industries. Individually, the Shewhart EWMA charts are only sensitive to large and small shifts, respectively. To enhance the detection abilities of the two schemes in monitoring all kinds of shifts in Poisson count data, this study examines the performance of combined applications of the Shewhart, and EWMA Poisson control charts. Furthermore, the study proposes modifications based on well-structured statistical data collection technique, ranked set sampling (RSS), to detect shifts in the mean of a Poisson process more quickly. The relative performance of the proposed Shewhart-EWMA Poisson location charts is evaluated in terms of the average run length (ARL), standard deviation of the run length (SDRL), median run length (MRL), average ratio ARL (ARARL), average extra quadratic loss (AEQL) and performance comparison index (PCI). Consequently, all the new Poisson control charts based on RSS method are generally more superior than most of the existing schemes for monitoring Poisson processes. The use of these combined Shewhart-EWMA Poisson charts is illustrated with an example to demonstrate the practical implementation of the design procedure.

  8. Overview of the consortium of hospitals advancing research on tobacco (chart

    Directory of Open Access Journals (Sweden)

    Riley William T

    2012-08-01

    Full Text Available Abstract Background The Consortium of Hospitals Advancing Research on Tobacco (CHART is a network of six projects and a research coordinating unit funded by the National Heart, Lung, and Blood Institute, the National Cancer Institute, the National Institute on Drug Abuse, and the National Institutes of Health (NIH Office of Behavioral and Social Science Research. The CHART projects will assess the effectiveness and cost-effectiveness of smoking cessation interventions initiated during hospitalization and continued post-discharge. Methods/design Along with a seventh project funded previously under the NIH Challenge grants, the CHART projects will assess smoking cessation strategies delivered to approximately 10,000 hospitalized smokers across a geographically diverse group of nearly 20 private, public, academic, and community hospitals. The CHART research coordinating unit at Kaiser Permanente Center for Health Research provides organizational and data coordination support, facilitating the development of common measures for combining data from multiple CHART projects. Discussion The targeted enrollment in CHART, if achieved, will represent the largest, most diverse pooled dataset of hospitalized smokers receiving smoking cessation assistance, and is designed to contribute to the dissemination and implementation of smoking cessation interventions provided by hospital systems.

  9. Arctic Sea Ice Charts from Danish Meteorological Institute, 1893 - 1956

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — From 1893 to 1956, the Danish Meteorological Institute (DMI) created charts of observed and inferred sea ice extent for each summer month. These charts are based on...

  10. Science comic-strips on display at Microcosm

    CERN Document Server

    Alix Marcastel

    2011-01-01

    To mark the publication of his new comic-strip "Les Vies de Marie Curie", the Genevan artist Fiami will be placing some of his previous creations on the theme "women and science" on display at CERN. The new comic-strip pays tribute to the illustrious Nobel prize-winner by taking a light-hearted look at the history of chemistry and how the role of women scientists in society has evolved through the ages.   It's no easy task,  presenting the history of science to the general public in a light-hearted way. As part of the various events organised in the Fête de la Science and the Europeans Researchers Night, CERN will be hosting an exhibition entirely devoted to the comic-strips created by Fiami. The artist describes his comics as "a relaxed way of looking at serious and apparently highly complex subjects."  Fiami's very latest creation, Les Vies de Marie Curie, published in June 2011, celebrates th...

  11. 46 CFR 97.05-5 - Charts and nautical publications.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Charts and nautical publications. 97.05-5 Section 97.05... OPERATIONS Notice to Mariners and Aids to Navigation § 97.05-5 Charts and nautical publications. As... tables; (g) Current tables; and (h) All other nautical publications necessary. 1 1 For United States...

  12. MINIMIZING GLOVEBOX GLOVE BREACHES, PART IV: CONTROL CHARTS

    International Nuclear Information System (INIS)

    Cournoyer, Michael E.; Lee, Michelle B.; Schreiber, Stephen B.

    2007-01-01

    At the Los Alamos National Laboratory (LANL) Plutonium Facility, plutonium. isotopes and other actinides are handled in a glovebox environment. The spread of radiological contamination, and excursions of contaminants into the worker's breathing zone, are minimized and/or prevented through the use of glovebox technology. Evaluating the glovebox configuration, the glovebo gloves are the most vulnerable part of this engineering control. Recognizing this vulnerability, the Glovebox Glove Integrity Program (GGIP) was developed to minimize and/or prevent unplanned openings in the glovebox environment, i.e., glove failures and breaches. In addition, LANL implement the 'Lean Six Sigma (LSS)' program that incorporates the practices of Lean Manufacturing and Six Sigma technologies and tools to effectively improve administrative and engineering controls and work processes. One tool used in LSS is the use of control charts, which is an effective way to characterize data collected from unplanned openings in the glovebox environment. The benefit management receives from using this tool is two-fold. First, control charts signal the absence or presence of systematic variations that result in process instability, in relation to glovebox glove breaches and failures. Second, these graphical representations of process variation detennine whether an improved process is under control. Further, control charts are used to identify statistically significant variations (trends) that can be used in decision making to improve processes. This paper discusses performance indicators assessed by the use control charts, provides examples of control charts, and shows how managers use the results to make decisions. This effort contributes to LANL Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations.

  13. The Argonne silicon strip-detector array

    Energy Technology Data Exchange (ETDEWEB)

    Wuosmaa, A H; Back, B B; Betts, R R; Freer, M; Gehring, J; Glagola, B G; Happ, Th; Henderson, D J; Wilt, P [Argonne National Lab., IL (United States); Bearden, I G [Purdue Univ., Lafayette, IN (United States). Dept. of Physics

    1992-08-01

    Many nuclear physics experiments require the ability to analyze events in which large numbers of charged particles are detected and identified simultaneously, with good resolution and high efficiency, either alone, or in coincidence with gamma rays. The authors have constructed a compact large-area detector array to measure these processes efficiently and with excellent energy resolution. The array consists of four double-sided silicon strip detectors, each 5x5 cm{sup 2} in area, with front and back sides divided into 16 strips. To exploit the capability of the device fully, a system to read each strip-detector segment has been designed and constructed, based around a custom-built multi-channel preamplifier. The remainder of the system consists of high-density CAMAC modules, including multi-channel discriminators, charge-sensing analog-to-digital converters, and time-to-digital converters. The array`s performance has been evaluated using alpha-particle sources, and in a number of experiments conducted at Argonne and elsewhere. Energy resolutions of {Delta}E {approx} 20-30 keV have been observed for 5 to 8 MeV alpha particles, as well as time resolutions {Delta}T {<=} 500 ps. 4 figs.

  14. Determination of residual stresses in roll compacted titanium strips

    CSIR Research Space (South Africa)

    Mothosi, KL

    2017-01-01

    Full Text Available residual stresses using x-ray diffraction (XRD) surface probing technique. Preliminary results were obtained for the surface residual stress at the center of the titanium strips for the 100 and 325 mesh strips rolled at 0.1 roll gap for 20 and 50 mm set...

  15. Optimising carbon electrode materials for adsorptive stripping voltammetry

    OpenAIRE

    Chaisiwamongkhol, K; Batchelor-McAuley, C; Sokolov, S; Holter, J; Young, N; Compton, R

    2017-01-01

    Different types of carbon electrode materials for adsorptive stripping voltammetry are studied through the use of cyclic voltammetry. Capsaicin is utilised as a model compound for adsorptive stripping voltammetry using unmodified and modified basal plane pyrolytic graphite (BPPG) electrodes modified with multi-walled carbon nanotubes, carbon black or graphene nanoplatelets, screen printed carbon electrodes (SPE), carbon nanotube modified screen printed electrodes, and carbon paste electrodes....

  16. Method of stripping solid particles

    International Nuclear Information System (INIS)

    1980-01-01

    A method of stripping loaded solid particles is specified in which uniform batches of the loaded particles are passed successively upwardly through an elution column in the form of discrete plugs, the particles of which do not intermingle substantially with the particles of the vertically adjacent plug(s), and are contacted therein with eluant liquid flowed downwardly, strong eluate being withdrawn from the lower region of the column, the loaded particles being supplied as a slurry in a carrier liquid, and successive batches of loaded particles being isolated as measured batches and being separated from their carrier liquid before being contacted with strong eluate and slurried with the strong eluate into the lower region of the column. An example describes the stripping of ion exchange resin particles loaded with complex uranium ions. (author)

  17. Process for recovering uranium using an alkyl pyrophosphoric acid and alkaline stripping solution

    International Nuclear Information System (INIS)

    Worthington, R.E.; Magdics, A.

    1987-01-01

    A process is described for stripping uranium for a pregnant organic extractant comprising an alkyl pyrophosphoric acid dissolved in a substantially water-immiscible organic diluent. The organic extractant contains tetravalent uranium and an alcohol or phenol modifier in a quantity sufficient to retain substantially all the unhydrolyzed alkyl pyrophosphoric acid in solution in the diluent during stripping. The process comprises adding an oxidizing agent to the organic extractant and thereby oxidizing the tetravalent uranium to the +6 state in the organic extractant, and contacting the organic extractant containing the uranium in the +6 state with a stripping solution comprising an aqueous solution of an alkali metal or ammonium carbonate or hydroxide thereby stripping uranium from the organic extractant into the stripping solution. The resulting barren organic extractant containing substantially all of the unhydrolyzed alkyl pyrophosphoric acid dissolved in the diluent is separated from the stripping solution containing the stripped uranium, the barren extractant being suitable for recycle

  18. A simulation training evaluation method for distribution network fault based on radar chart

    Directory of Open Access Journals (Sweden)

    Yuhang Xu

    2018-01-01

    Full Text Available In order to solve the problem of automatic evaluation of dispatcher fault simulation training in distribution network, a simulation training evaluation method based on radar chart for distribution network fault is proposed. The fault handling information matrix is established to record the dispatcher fault handling operation sequence and operation information. The four situations of the dispatcher fault isolation operation are analyzed. The fault handling anti-misoperation rule set is established to describe the rules prohibiting dispatcher operation. Based on the idea of artificial intelligence reasoning, the feasibility of dispatcher fault handling is described by the feasibility index. The relevant factors and evaluation methods are discussed from the three aspects of the fault handling result feasibility, the anti-misoperation correctness and the operation process conciseness. The detailed calculation formula is given. Combining the independence and correlation between the three evaluation angles, a comprehensive evaluation method of distribution network fault simulation training based on radar chart is proposed. The method can comprehensively reflect the fault handling process of dispatchers, and comprehensively evaluate the fault handling process from various angles, which has good practical value.

  19. Overall model of the dynamic behaviour of the steel strip in an annealing heating furnace on a hot-dip galvanizing line

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-de-Pison, F.J.; Pernia, A.; Jimenez-Macias, E.; Fernandez, R.

    2010-07-01

    Predicting the temperature of the steel strip in the annealing process in a hot-dip galvanizing line (HDGL) is important to ensure the physical properties of the processed material. The development of an accurate model that is capable of predicting the temperature the strip will reach according to the furnaces variations in temperature and speed, its dimensions and the steels chemical properties, is a requirement that is being increasingly called for by industrial plants of this nature. This paper presents a comparative study made between several types of algorithms of Data Mining and Artificial Intelligence for the design of an efficient and overall prediction model that will allow determining the strips variation in temperature according to the physico-chemical specifications of the coils to be processed, and fluctuations in temperature and speed that are recorded within the annealing process. The ultimate goal is to find a model that is effectively applicable to coils of new types of steel or sizes that are being processed for the first time. This model renders it possible to fine-tune the control model in order to standardise the treatment in areas of the strip in which there is a transition between coils of different sizes or types of steel. (Author).

  20. Single electron attachment and stripping cross sections for relativistic heavy ions

    International Nuclear Information System (INIS)

    Crawford, H.J.

    1979-06-01

    The results of a Bevalac experiment to measure the single electron attachment and stripping cross sections for relativistic (0.5 1 , and fully stripped, N 0 , ion beams emerging from the targets. Separate counters measured the number of ions in each charge state. The ratios N 1 /N 0 for different target thicknesses were fit to a simple growth curve to yield electron attachment and stripping cross sections. The data are compared to relativistic extrapolations of available theories. Clear evidence for two separate attachment processes, radiative and non-radiative, is found. Data are compared to a recently improved formulation for the stripping cross sections

  1. Observational study on the pavement performance effects of shoulder rumble strip on shoulders

    Directory of Open Access Journals (Sweden)

    Sean Coffey

    2016-07-01

    Full Text Available Rumble strip implementation has shown a constant increase with its safety benefits. Rumble strips are milled into the roadway shoulder to produce noise and vibrations when driven on. With the milling process, the pavement performance is expected to be negatively impacted by the decreased depth, though not mathematically quantified. Using methods defined by the Long-Term Pavement Performance Program, the severity of the shoulder site’s distresses, with and without shoulder rumble strips, will be quantified. The quantification would permit the design to compensate for the impact. This design compensation allows the implementation of hard shoulder running, the use of shoulder as a travel lane during congestion, and retains the shoulder rumble strip safety instead of removing, as suggested by some proposed projects. While hard shoulder running would not impact specific time periods, the safety benefit of rumble strips could be needed at any time. This study aims to quantify the rumble strip impact to enable the full shoulder strength for hard shoulder running while retaining the safety benefits of rumble strips. Keywords: Rumble strips, Shoulder, Cracking, Pavement performance, Hard shoulder running

  2. 46 CFR 26.03-4 - Charts and nautical publications.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Charts and nautical publications. 26.03-4 Section 26.03... Operating Requirements § 26.03-4 Charts and nautical publications. (a) As appropriate for the intended... navigation possible; (2) “U.S. Coast Pilot” or similar publication; (3) Coast Guard light list; (4) Tide...

  3. slice of LEP beamtube with getter strip

    CERN Multimedia

    1989-01-01

    A section of the LEP beam pipe. This is the chamber in which LEP's counter-rotating electron and positron beams travel. It is made of lead-clad aluminium. The beams circulate in the oval cross-section part of the chamber. In the rectangular cross-section part, LEP's innovative getter-strip vacuum pump is installed. After heating to purify the surface of the getter, the strip acts like molecular sticky tape, trapping any stray molecules left behind after the accelerator's traditional vacuum pumps have done their job.

  4. Influence for high intensity irradiation on characteristics of silicon strip-detectors

    International Nuclear Information System (INIS)

    Anokhin, I.E.; Pugatch, V.M.; Zinets, O.S.

    1995-01-01

    Full text: Silicon strip detectors (SSD) are widely used for the coordinate determination of short-range as well as minimum ionizing particles with high spatial resolution. Submicron position sensitivity of strip-detectors for short-range particles has been studied by means of two dimensional analyses of charges collected by neighboring strips as well as by measurement of charge collection times [1]. Silicon strip detectors was also used for testing high energy electron beam [2]. Under large fluences the radiation defects are stored and such characteristics of strip-detectors as an accuracy of the coordinate determination and the registration efficiency are significantly changed. Radiation defects lead to a decrease of the lifetime and mobility of charge carriers and therefore to changes of conditions for the charge collection in detectors. The inhomogeneity in spatial distribution if defects and electrical field plays an important role in the charge collection. In this report the role of the diffusion and drift in the charge collection in silicon strip-detectors under irradiation up to 10 Mrad has been studied. The electric field distribution and its dependence on the radiation dose in the detector have been calculated. It is shown that for particles incident between adjacent strips the coordinate determination precision depends strongly on the detector geometry and the electric field distribution, particularly in the vicinity of strips. Measuring simultaneously the collected charges and collection times on adjacent strips one can essentially improve reliability of the coordinate determination for short-range particles. Usually SSD are fabricated on n-type wafers. It is well known that under high intensity irradiation n-Si material converts into p-Si as far as p-type silicon is more radiative hard than n-type silicon [3] it is reasonable to fabricate SSD using high resistivity p-Si. Characteristics of SSD in basis n-and P-Si have been compared and higher

  5. Comparisons of boll weevil (Coleoptera: Curculionidae) pheromone traps with and without kill strips.

    Science.gov (United States)

    Suh, C P C; Armstrong, J S; Spurgeon, D W; Duke, S

    2009-02-01

    Boll weevil, Anthonomus grandis grandis Boheman (Coleoptera: Curculionidae), eradication programs typically equip pheromone traps with an insecticide-impregnated kill strip. These strips are intended to kill captured insects, thereby simplifying trap servicing and reducing the loss of weevils from predation and escape. However, the effectiveness of kill strips has not been extensively evaluated. We examined the influences of kill strips on weevil captures, trap servicing, and the incidences of weevil predation and trap obstruction (e.g., by spider webs). Evaluations were conducted weekly during three different production periods (pre- to early-, late-, and postseason) of cotton, Gossypium hirsutum L., to represent different environmental conditions and weevil population levels. Within each period, mean weekly captures of weevils in traps with and without kill strips were statistically similar. On average, traps with kill strips took 9 s longer to service than traps without kill strips, but statistical differences were only detected during the late-season period. Overall, the mean weekly proportion of traps with evidence of weevil predation or trap obstruction was significantly lower for traps with kill strips (0.25) than for traps without kill strips (0.37). However, this reduction in the frequency of weevil predation or trap obstruction was too small to produce a corresponding increase in the numbers of weevils captured. In light of these findings, the use of kill strips is likely unnecessary in eradication programs, but may be a consideration in situations when the numbers of deployed traps are reduced and chronic problems with weevil predation or trap obstruction exist.

  6. Safe Minimum Internal Temperature Chart

    Science.gov (United States)

    ... Internal Temperature Chart Safe steps in food handling, cooking, and storage are essential in preventing foodborne illness. You can't see, smell, or taste harmful bacteria that may cause illness. In every step of food preparation, follow the four guidelines to keep food safe: ...

  7. A qualitative study exploring nurses’ attitudes, confidence, and perceived barriers to implementing a traumatic brain injury nursing chart in Uganda

    Directory of Open Access Journals (Sweden)

    Leslie Wynveen

    2018-06-01

    Full Text Available Introduction: In Africa, traumatic brain injuries frequently result from road traffic injuries and assaults. Despite limited resources and the high costs of life-saving neurosurgical interventions, secondary brain injury prevention has the potential for improving outcomes. However, nurses and other medical personnel infrequently monitor vital signs, blood sugar, and pulse oximetry and only sporadically re-assess neurological status. Methods: In one-on-one, semi-structured interviews, 27 nurses from Mulago Hospital’s emergency centre, a tertiary care trauma hospital in Kampala, Uganda, provided feedback regarding a traumatic brain injury-focused education session and use of a nursing chart for detecting secondary brain injury. The interviews explored the nurses’ confidence and perceived barriers to long-term chart implementation and traumatic brain injury care, as well as their ideas for improving this intervention. Interviews were audio recorded, transcribed, and coded using ATLAS.ti: Qualitative Data Analysis and Research Software (Cleverbridge, Inc., Chicago, USA and Microsoft Word and Excel (Microsoft Office, Redmond, USA for thematic content analysis. Results: Key findings identified in the interviews included the nurses’ attitudes toward the chart and their feelings of increased confidence in assessing and caring for these patients. The main barriers to continuous implementation included inadequate staffing and resources. Conclusion: Nurses were receptive to the education session and nursing chart, and felt that it increased their confidence and improved their ability to care for traumatic brain injured patients. However, lack of supplies, overwhelming numbers of patients, and inadequate staffing interfered with consistent monitoring of patients. The nurses offered various suggestions for improving traumatic brain injury care that should be further investigated. More research is needed to assess the applicability of a standardised

  8. Building information for systematic improvement of the prevention of hospital-acquired pressure ulcers with statistical process control charts and regression.

    Science.gov (United States)

    Padula, William V; Mishra, Manish K; Weaver, Christopher D; Yilmaz, Taygan; Splaine, Mark E

    2012-06-01

    To demonstrate complementary results of regression and statistical process control (SPC) chart analyses for hospital-acquired pressure ulcers (HAPUs), and identify possible links between changes and opportunities for improvement between hospital microsystems and macrosystems. Ordinary least squares and panel data regression of retrospective hospital billing data, and SPC charts of prospective patient records for a US tertiary-care facility (2004-2007). A prospective cohort of hospital inpatients at risk for HAPUs was the study population. There were 337 HAPU incidences hospital wide among 43 844 inpatients. A probit regression model predicted the correlation of age, gender and length of stay on HAPU incidence (pseudo R(2)=0.096). Panel data analysis determined that for each additional day in the hospital, there was a 0.28% increase in the likelihood of HAPU incidence. A p-chart of HAPU incidence showed a mean incidence rate of 1.17% remaining in statistical control. A t-chart showed the average time between events for the last 25 HAPUs was 13.25 days. There was one 57-day period between two incidences during the observation period. A p-chart addressing Braden scale assessments showed that 40.5% of all patients were risk stratified for HAPUs upon admission. SPC charts complement standard regression analysis. SPC amplifies patient outcomes at the microsystem level and is useful for guiding quality improvement. Macrosystems should monitor effective quality improvement initiatives in microsystems and aid the spread of successful initiatives to other microsystems, followed by system-wide analysis with regression. Although HAPU incidence in this study is below the national mean, there is still room to improve HAPU incidence in this hospital setting since 0% incidence is theoretically achievable. Further assessment of pressure ulcer incidence could illustrate improvement in the quality of care and prevent HAPUs.

  9. Geo structural chart of Uruguay. Scale 1/2.000.000

    International Nuclear Information System (INIS)

    Preciozzi, F.; Spoturno, F.; Heinzen, W.

    1979-01-01

    This work is about the Geo-Structural Chart of Uruguay , Esca le 1 / 2,000,000. The geological information synthesis in the country, obtained from: published geological work or whose information is registered by laboratory work and geophysical surveys. This Chart will allow an overview of the degree of geological knowledge of Uruguay, restricted to the limits imposed by the scale of this work. The realization of this Chart included a thorough and careful compilation, critical analysis, standardization and interpretation of all geological and geophysical maps available in the country

  10. HOTELLING'S T2 CONTROL CHARTS BASED ON ROBUST ESTIMATORS

    Directory of Open Access Journals (Sweden)

    SERGIO YÁÑEZ

    2010-01-01

    Full Text Available Under the presence of multivariate outliers, in a Phase I analysis of historical set of data, the T 2 control chart based on the usual sample mean vector and sample variance covariance matrix performs poorly. Several alternative estimators have been proposed. Among them, estimators based on the minimum volume ellipsoid (MVE and the minimum covariance determinant (MCD are powerful in detecting a reasonable number of outliers. In this paper we propose a T 2 control chart using the biweight S estimators for the location and dispersion parameters when monitoring multivariate individual observations. Simulation studies show that this method outperforms the T 2 control chart based on MVE estimators for a small number of observations.

  11. Time contour expression of limited range phenomena on stack chart; Jugo chart jo deno kyokuchi gensho jikan contour

    Energy Technology Data Exchange (ETDEWEB)

    Kametani, T

    1997-05-27

    Time contour expression of limited range phenomena on stack chart is examined for further improvement on the result of the ultimate interpretation in the seismic reflection survey. The policy is made clear from the beginning that local phenomena are to be discussed, and data prior CMP stacking is interpreted in detail. For this purpose, it is effective to make use of the time contour expression in the midpoint-offset plane simultaneously with the CMP and COP panels. For the review of data prior to CMP stacking, it is convenient to use the CMP (CDP) stacking chart in which the data is arranged methodically. In this chart, all the channels which are crude data prior to stacking are plotted on midpoint-offset coordinates, which plane is called the MOD (Midpoint Offset Domain) panel. Various panels can be chosen unrestrictedly, and their mutual relations can be easily grasped. When data points are given a time axis, they can be expressed in a time contour. Studies are conducted about the underground structure, multiple reflection paths divided by it, and characteristics of detour reflection attributable to faults. 4 refs., 9 figs.

  12. Electronic dental records: start taking the steps.

    Science.gov (United States)

    Bergoff, Jana

    2011-01-01

    Converting paper patient records charts into their electronic counterparts (EDRs) not only has many advantages, but also could become a legal requirement in the future. Several steps key to a successful transition includes assessing the needs of the dental team and what they require as a part of the implementation Existing software and hardware must be evaluated for continued use and expansion. Proper protocols for information transfer must be established to ensure complete records while maintaining HIPAA regulations regarding patient privacy. Reduce anxiety by setting realistic dead-lines and using trusted back-up methods.

  13. Numerical analysis of edge effects in side illuminated strip detectors for digital radiology

    CERN Document Server

    Krizaj, D

    2000-01-01

    The influence of edge defects on side illuminated X-ray strip detectors for digital radiology is investigated by numerical device modeling. By assuming positive fixed oxide charges on side and top surfaces simulations have shown strong curvature of the equipotential lines in the edge region. A fraction of the edge generated current surpasses the edge guard-ring junction and is collected by the readout strips. As a consequence, strips cannot be placed close to the edge of the structure and collection efficiency is reduced. An n-on-n instead of a p-on-n strip detector is proposed enabling collection of edge generated carriers by a very narrow guard-ring junction and placement of the readout strip close to the edge without increase of the strip leakage current.

  14. A design chart for long vacuum pipes and shells

    International Nuclear Information System (INIS)

    Krempetz, K.; Grimson, J.; Kelly, P.

    1986-01-01

    This paper presents a design chart to aid designers in the selection of a wall thickness for long cylindrical shells having atmospheric pressure outside the shell and a pressure less than atmospheric inside the shell. The chart indicates a conservative value for the minimum wall thickness for a given shell diameter and material when the shell is completely evacuated

  15. 46 CFR 78.05-5 - Charts and nautical publications.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Charts and nautical publications. 78.05-5 Section 78.05... Notice to Mariners and Aids to Navigation § 78.05-5 Charts and nautical publications. As appropriate for... publications necessary. 1 1 For United States vessels in or on the navigable waters of the United States, see...

  16. Generalized thick strip modelling for vortex-induced vibration of long flexible cylinders

    International Nuclear Information System (INIS)

    Bao, Y.; Palacios, R.; Graham, M.; Sherwin, S.

    2016-01-01

    We propose a generalized strip modelling method that is computationally efficient for the VIV prediction of long flexible cylinders in three-dimensional incompressible flow. In order to overcome the shortcomings of conventional strip-theory-based 2D models, the fluid domain is divided into “thick” strips, which are sufficiently thick to locally resolve the small scale turbulence effects and three dimensionality of the flow around the cylinder. An attractive feature of the model is that we independently construct a three-dimensional scale resolving model for individual strips, which have local spanwise scale along the cylinder's axial direction and are only coupled through the structural model of the cylinder. Therefore, this approach is able to cover the full spectrum for fully resolved 3D modelling to 2D strip theory. The connection between these strips is achieved through the calculation of a tensioned beam equation, which is used to represent the dynamics of the flexible body. In the limit, however, a single “thick” strip would fill the full 3D domain. A parallel Fourier spectral/hp element method is employed to solve the 3D flow dynamics in the strip-domain, and then the VIV response prediction is achieved through the strip–structure interactions. Numerical tests on both laminar and turbulent flows as well as the comparison against the fully resolved DNS are presented to demonstrate the applicability of this approach.

  17. Generalized thick strip modelling for vortex-induced vibration of long flexible cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Bao, Y., E-mail: ybao@sjtu.edu.cn [Department of Civil Engineering, School of Naval Architecture, Ocean and Civil Engineering, Shanghai Jiaotong University, No. 800 Dongchuan Road, Shanghai (China); Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom); Palacios, R., E-mail: r.palacios@imperial.ac.uk [Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom); Graham, M., E-mail: m.graham@imperial.ac.uk [Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom); Sherwin, S., E-mail: s.sherwin@imperial.ac.uk [Department of Aeronautics, Imperial College London, South Kensington Campus, London (United Kingdom)

    2016-09-15

    We propose a generalized strip modelling method that is computationally efficient for the VIV prediction of long flexible cylinders in three-dimensional incompressible flow. In order to overcome the shortcomings of conventional strip-theory-based 2D models, the fluid domain is divided into “thick” strips, which are sufficiently thick to locally resolve the small scale turbulence effects and three dimensionality of the flow around the cylinder. An attractive feature of the model is that we independently construct a three-dimensional scale resolving model for individual strips, which have local spanwise scale along the cylinder's axial direction and are only coupled through the structural model of the cylinder. Therefore, this approach is able to cover the full spectrum for fully resolved 3D modelling to 2D strip theory. The connection between these strips is achieved through the calculation of a tensioned beam equation, which is used to represent the dynamics of the flexible body. In the limit, however, a single “thick” strip would fill the full 3D domain. A parallel Fourier spectral/hp element method is employed to solve the 3D flow dynamics in the strip-domain, and then the VIV response prediction is achieved through the strip–structure interactions. Numerical tests on both laminar and turbulent flows as well as the comparison against the fully resolved DNS are presented to demonstrate the applicability of this approach.

  18. Design, Analysis, and On-Sun Evaluation of Reflective Strips Under Controlled Buckling

    Science.gov (United States)

    Jaworske, Donald A.; Sechkar, Edward A.; Colozza, Anthony J.

    2014-01-01

    Solar concentrators are envisioned for use in a variety of space-based applications, including applications involving in situ resource utilization. Identifying solar concentrators that minimize mass and cost are of great interest, especially since launch cost is driven in part by the mass of the payload. Concentrators must also be able to survive the wide temperature excursions on the lunar surface. Identifying smart structures which compensate for changes in concentrator geometry brought about by temperature extremes are of interest. Some applications may benefit from the ability to change the concentrators focal pattern at will. This paper addresses a method of designing a single reflective strip to produce a desired focal pattern through the use of controlled buckling. Small variations in the cross section over the length of the reflective strip influence the distribution of light in the focal region. A finite element method of analysis is utilized here which calculates the curve produced for a given strip cross section and axial load. Varying axial force and strip cross section over the length of the reflective strip provide a means of optimizing ray convergence in the focal region. Careful selection of a tapered cross section yields a reflective strip that approximates a parabola. An array of reflective strips under controlled buckling produces a light weight concentrator and adjustments in the compression of individual strips provide a means of compensating for temperature excursions or changing the focal pattern at will.

  19. Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00389527; The ATLAS collaboration

    2016-01-01

    Resistive strip Micromegas detectors are discharge tolerant. They have been tested extensively as small detectors of about 10 x 10 cm$^2$ in size and they work reliably at high rates of 100 kHz/cm$^2$ and above. Tracking resolution well below 100 $\\mu$m has been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3 m$^2$ in size. To investigate possible differences between small and large detectors, a 1 m$^2$ detector with 2048 resistive strips at a pitch of 450 $\\mu$m was studied in the LMU Cosmic Ray Measurement Facility (CRMF) using two 4 $\\times$ 2.2 m$^2$ large Monitored Drift Tube (MDT) chambers for cosmic muon reference tracking. A segmentation of the resistive strip anode plane in 57.6 mm x 93 mm large areas has been realized by the readout of 128 strips with one APV25 chip each and by eleven 93 mm broad trigger scintillators placed along the readout strips. This allows for mapping of homogeneity in pulse height and efficiency, d...

  20. Borehole DC-6 hydrostratigraphic chart

    International Nuclear Information System (INIS)

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart for Borehole DC-6 identifies the basic stratigraphy and preliminary hydrologic test results. This borehole was cored for obtaining stratigraphic data and only that portion within the Grande Ronde formation remains open for hydrologic testing. The upper two formations were cased and cemented off

  1. About the National Forecast Chart

    Science.gov (United States)

    code. Press enter or select the go button to submit request Local forecast by "City, St" or Prediction Center on Twitter NCEP Quarterly Newsletter WPC Home Analyses and Forecasts National Forecast to all federal, state, and local government web resources and services. The National Forecast Charts

  2. Data analytics and parallel-coordinate materials property charts

    Science.gov (United States)

    Rickman, Jeffrey M.

    2018-01-01

    It is often advantageous to display material properties relationships in the form of charts that highlight important correlations and thereby enhance our understanding of materials behavior and facilitate materials selection. Unfortunately, in many cases, these correlations are highly multidimensional in nature, and one typically employs low-dimensional cross-sections of the property space to convey some aspects of these relationships. To overcome some of these difficulties, in this work we employ methods of data analytics in conjunction with a visualization strategy, known as parallel coordinates, to represent better multidimensional materials data and to extract useful relationships among properties. We illustrate the utility of this approach by the construction and systematic analysis of multidimensional materials properties charts for metallic and ceramic systems. These charts simplify the description of high-dimensional geometry, enable dimensional reduction and the identification of significant property correlations and underline distinctions among different materials classes.

  3. Silicon Strip Detectors for ATLAS at the HL-LHC Upgrade

    CERN Document Server

    Hara, K; The ATLAS collaboration

    2012-01-01

    The present ATLAS silicon strip (SCT) and transition radiation (TRT) trackers will be replaced with new silicon strip detectors, as part of the Inner Tracker System (ITK), for the Phase-2 upgrade of the Large Hadron Collider, HL-LHC. We have carried out intensive R&D programs to establish radiation harder strip detectors that can survive in a radiation level up to 3000 fb-1 of integrated luminosity based on n+-on-p microstrip detector. We describe main specifications for this year’s sensor fabrication, followed by a description of possible module integration schema

  4. Test strip and method for its use

    International Nuclear Information System (INIS)

    1981-01-01

    A test strip device is described which is useful in performing binding assays involving antigens, antibodies, hormones, vitamins, metabolites or pharmacological agents. The device is capable of application to analytical methods in which a set of sequential test reactions is involved and in which a minute sample size may be used. This test strip is particularly useful in radioimmunoassays. The use of the device is illustrated in radioimmunoassays for 1) thyroxine in serum, 2) the triiodothyronine binding capacity of serum and 3) folic acid and its analogues in serum. (U.K.)

  5. Wide Strip Casting Technology of Magnesium Alloys

    Science.gov (United States)

    Park, W.-J.; Kim, J. J.; Kim, I. J.; Choo, D.

    Extensive investigations relating to the production of high performance and low cost magnesium sheet by strip casting have been performed for the application to automotive parts and electronic devices. Research on magnesium sheet production technology started in 2004 by Research Institute of Industrial Science and Technology (RIST) with support of Pohang Iron and Steel Company (POSCO). POSCO has completed the world's first plant to manufacture magnesium coil. Another big project in order to develop wide strip casting technology for the automotive applications of magnesium sheets was started in succession.

  6. Asset Stripping in a Mature Market Economy

    DEFF Research Database (Denmark)

    Klarskov Jeppesen, Kim; Møller, Ulrik Gorm

    2011-01-01

    Purpose – The purpose of this paper is to document a Danish fraud scheme, in which a large number of limited companies were stripped of their assets leaving them with nothing but tax debt, eventually causing the Danish Tax and Customs Administration to lose large sums. Furthermore, the purpose...... indicates that asset stripping may take place in mature market economies to the extent that perpetrators are able to circumvent the corporate governance system by giving lawyers, public accountants and banks incentives to act less critically towards dubious business transactions. Research limitations...

  7. Development of a fetal weight chart using serial trans-abdominal ultrasound in an East African population

    DEFF Research Database (Denmark)

    Schmiegelow, Christentze; Scheike, Thomas; Oesterholt, Mayke

    2012-01-01

    OBJECTIVE: To produce a fetal weight chart representative of a Tanzanian population, and compare it to weight charts from Sub-Saharan Africa and the developed world. METHODS: A longitudinal observational study in Northeastern Tanzania. Pregnant women were followed throughout pregnancy with serial...... trans-abdominal ultrasound. All pregnancies with pathology were excluded and a chart representing the optimal growth potential was developed using fetal weights and birth weights. The weight chart was compared to a chart from Congo, a chart representing a white population, and a chart representing...... a white population but adapted to the study population. The prevalence of SGA was assessed using all four charts. RESULTS: A total of 2193 weight measurements from 583 fetuses/newborns were included in the fetal weight chart. Our chart had lower percentiles than all the other charts. Most importantly...

  8. Apparatus for irradiating a continuous line metallic strip with electron beams

    International Nuclear Information System (INIS)

    Matsuda, Shozo; Tanaka, Tadashi; Okamoto, Tadaaki; Ueno, Nagaharu.

    1970-01-01

    The secondary X-rays from an irradiated object are completely shielded by providing direction-change rollers between applicator rollers and irradiation devices. The substrate strip turns its direction of travel by 90 0 through idle rollers and before it enters a front side applicator roller. After the application of coatings, the strip travels over a roller to turn upwardly, so that the applicator is isolated from the following irradiation enclosure. Next, the irradiated strip changes its direction by 90 0 through a roller to enter a bake side coating applicator. After a direction change through a roller, the strip enters the irradiation enclosure. In this way, the applicators can prevent leakage of secondary X-rays. (Iwakiri, K.)

  9. Interactive Financial Charts- Agency Financial Reports

    Data.gov (United States)

    General Services Administration — For a visual depiction of GSA's Balance Sheet and Statement of Net Cost, please use the interactive charts to view the financial results for fiscal years 2007-2013.

  10. Development of mild steel exposure chart for neutron radiography application

    International Nuclear Information System (INIS)

    Hafizal Yazid; Rafhayudi Jamro; Hishamuddin Husain; Muhammad Rawi Mohd Zin; Razali Kassim; Abd Aziz Mohamed; Azali Muhammad

    2004-01-01

    A neutron radiography exposure chart for mild steel was developed to facilitate the determination of exposure time when producing neutron radiographs for any given mild steel thickness. A mild steel sample in the form of step wedge (1-10 mm thick) was exposed to thermal neutron using Direct technique. This technique involves exposing x-ray film-Gadolinium converter housed in one film cassette simultaneously to thermal neutron beam. Gadolinium converters with thickness of 0.025 mm and 0.5 mm were used to observe the effect of converter thickness on radiographic density and exposure time. Collected radiographic density data is then calculated based on manufacturer's film characteristic chart and finally exposure chart for mild steel was plotted. This chart could later be used as a guide for estimating exposure time for any given sample thickness providing other conditions are similar (material, film processing, neutron flux, film density and converter thickness). (Author)

  11. stripping of uranium from DEHPA/TOPO solvent by ammonium carbonate solutions

    International Nuclear Information System (INIS)

    Khorfan, S.; Shino, O.; Wahood, A.; Dahdouh, A.

    2002-01-01

    Uranium is recovered from phosphoric acid by the DEHPA/TOPO process. In this process uranium is stripped from the loaded DEHPA/TOPO solvent in the second cycle by an ammonium carbonate solution. This paper studied stripping of uranium from 0.3 Mol DEHPA/0.075 Mol TOPO in kerosene by different ammonium carbonate solutions. The ammonium carbonate solutions tested were either made locally from ammonia and carbon dioxide gases or commercial and laboratory grades available on the market. A comparison was made between these carbonate solutions in terms of purity, stripping efficiency and phase separation. Both stripping and phase separation were carried out under different conditions of phase ratio and concentrations. The results obtained showed that ammonium carbonate prepared from direct synthesis of ammonia and carbon dioxide gases had a high purity and gave the same stripping yield as the laboratory grade. The phase separation was also slightly improved using a pure synthesized ammonium carbonate solution. the phase separation was found to be best at concentration of 0.5 Mol/L ammonium carbonate solution and at a phase A/O of 1/1 and a temperature of 50 degree centigrade. It was possible to obtain >99% yield by operating 2 stripping stages counter currently under these conditions. (authors)

  12. Compton recoil electron tracking with silicon strip detectors

    International Nuclear Information System (INIS)

    O'Neill, T.J.; Ait-Ouamer, F.; Schwartz, I.; Tumer, O.T.; White, R.S.; Zych, A.D.

    1992-01-01

    The application of silicon strip detectors to Compton gamma ray astronomy telescopes is described in this paper. The Silicon Compton Recoil Telescope (SCRT) tracks Compton recoil electrons in silicon strip converters to provide a unique direction for Compton scattered gamma rays above 1 MeV. With strip detectors of modest positional and energy resolutions of 1 mm FWHM and 3% at 662 keV, respectively, 'true imaging' can be achieved to provide an order of magnitude improvement in sensitivity to 1.6 x 10 - 6 γ/cm 2 -s at 2 MeV. The results of extensive Monte Carlo calculations of recoil electrons traversing multiple layers of 200 micron silicon wafers are presented. Multiple Coulomb scattering of the recoil electron in the silicon wafer of the Compton interaction and the next adjacent wafer is the basic limitation to determining the electron's initial direction

  13. The Analysis of a Wideband Strip-Helical Antenna with 1.1 Turns

    Directory of Open Access Journals (Sweden)

    Xihui Tang

    2016-01-01

    Full Text Available A wideband strip-helical antenna with 1.1 turns is analyzed numerically and experimentally. By replacing the traditional wire helix with wide metallic strip, the forward traveling current on the strip helix with about one turn smoothly decays to the minimum value at the open end of the helix. Therefore, the strip helix can excite a wideband circular polarization (CP wave with 50-ohm impedance matching. The proposed antenna is printed on a hollow-cylinder with a substrate relative permittivity of εr=2.2 and a thickness of h=0.5 mm. A 50 Ω coaxial cable is directly connected to excite the strip-helical antenna without any additional impedance matching section. The ground plane is placed below the antenna in order to provide a directional radiation pattern. To demonstrate this method, a prototype of 1.1-turn strip-helical antenna is tested. The test shows that the proposed antenna can reach an overlapped bandwidth of 46% with height of 0.52λ0, where λ0 is the wavelength in free space at the center operation frequency.

  14. Modules and Front-End Electronics Developments for the ATLAS ITk Strips Upgrade

    CERN Document Server

    Garcia-Argos, Carlos; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment is currently preparing for an upgrade of the tracking system in the course of the High Luminosity LHC, scheduled for 2024. The existing Inner Detector will be replaced by an all-silicon Inner Tracker (ITk) with a pixel detector surrounded by a strip detector. The ITk strip detector consists of a four layer barrel and a forward region composed of six discs on each side of the barrel. The basic unit of the detector is the silicon-strip module, consisting of a sensor and one or more hybrid circuits that hold the read-out electronics. The geometries of the barrel and end-cap modules take into account the regions that they have to cover. In the central region, the detectors are rectangular with straight strips, whereas on the forward region the modules require wedge shaped sensors with varying strip length and pitch. The current prototyping phase has resulted in the ITk Strip Detector Technical Design Report (TDR), which kicks-off the pre-production readiness phase at the involved institutes. ...

  15. Modules and Front-End Electronics Developments for the ATLAS ITk Strips Upgrade

    CERN Document Server

    Garcia-Argos, Carlos; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment is currently preparing for an upgrade of the tracking system in the course of the High Luminosity LHC, scheduled for 2024. The existing Inner Detector will be replaced by an all-silicon Inner Tracker (ITk) with a pixel detector surrounded by a strip detector. The ITk strip detector consists of a four layer barrel and a forward region composed of six discs on each side of the barrel. The basic unit of the detector is the silicon-strip module, consisting of a sensor and one or more hybrid circuits that hold the read-out electronics. The geometries of the barrel and end-cap modules take into account the regions that they have to cover. In the central region, the detectors are rectangular with straight strips, whereas in the forward region the modules require wedge shaped sensors with varying strip length and pitch. The current prototyping phase has resulted in the ITk Strip Detector Technical Design Report (TDR), which kicks-off the pre-production readiness phase at the involved institutes. ...

  16. Minimal impact of an electronic medical records system.

    Science.gov (United States)

    Tall, Jill M; Hurd, Marie; Gifford, Thomas

    2015-05-01

    Electronic medical records (EMRs) implementation in hospitals and emergency departments (EDs) is becoming increasingly more common. The purpose of this study was to determine the impact of an EMR system on patient-related factors that correlate to ED workflow efficiency. A retrospective chart review assessed monthly census reports of all patients who registered and were treated to disposition during conversion from paper charts to an EMR system. The primary outcome measurement was an analysis of the time of registration to discharge or total ED length of stay as well as rate of those who left without being seen, eloped, or left against medical advice. These data were recorded from 3 periods, for 18 months: before installation of the EMR system (pre-EMR), during acclimation to the EMR, and post acclimation (post-EMR). A total of 61626 individual patient records were collected and analyzed. The total ED length of stay across all patient subtypes was not significantly affected by the installation of the hospital-wide EMR system (P = .481); however, a significant decrease was found for patients who were admitted to the hospital from the ED (P .25). Installation of a hospital-wide EMR system had minimal impact on workflow efficiency parameters in an ED. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Dual deflectable beam strip engine development.

    Science.gov (United States)

    Dulgeroff, C. R.; Zuccaro, D. E.; Kami, S.; Schnelker, D. E.; Ward, J. W.

    1972-01-01

    This paper describes a dual beam thruster that has been designed, constructed, and tested. The system is suitable for two-axes attitude control and is comprised of two orthogonal strips, each capable of producing 0.30 mlb thrust and beam deflections of more than plus or minus 20 deg. The nominal specific impulse for the thruster is 5000 sec, and the thrust level from each strip can be varied from 0 to 100%. Neutralizer filaments that were developed and life tested over 2000 hours producing more than 40 mA of electron emission per watt of input power are also discussed. The system power required for clean ionizers is approximately 200 W.

  18. Guideline implementation in clinical practice: use of statistical process control charts as visual feedback devices.

    Science.gov (United States)

    Al-Hussein, Fahad A

    2009-01-01

    To use statistical control charts in a series of audits to improve the acceptance and consistant use of guidelines, and reduce the variations in prescription processing in primary health care. A series of audits were done at the main satellite of King Saud Housing Family and Community Medicine Center, National Guard Health Affairs, Riyadh, where three general practitioners and six pharmacists provide outpatient care to about 3000 residents. Audits were carried out every fortnight to calculate the proportion of prescriptions that did not conform to the given guidelines of prescribing and dispensing. Simple random samples of thirty were chosen from a sampling frame of all prescriptions given in the two previous weeks. Thirty six audits were carried out from September 2004 to February 2006. P-charts were constructed around a parametric specification of non-conformities not exceeding 25%. Of the 1081 prescriptions, the most frequent non-conformity was failure to write generic names (35.5%), followed by the failure to record patient's weight (16.4%), pharmacist's name (14.3%), duration of therapy (9.1%), and the use of inappropriate abbreviations (6.0%). Initially, 100% of prescriptions did not conform to the guidelines, but within a period of three months, this came down to 40%. A process of audits in the context of statistical process control is necessary for any improvement in the implementation of guidelines in primary care. Statistical process control charts are an effective means of visual feedback to the care providers.

  19. PECULIAR FEATURES PERTAINING TO STRIP FORMATION FROM BAR

    Directory of Open Access Journals (Sweden)

    G. N. Zdor

    2010-01-01

    Full Text Available The paper describes results of calculations and presents experimental substantiation of the dependence of a strip width being rolled out of a 10-mm diameter bar on its final thickness. It has been shown that the formation technology of thin steel strips out of a round bar makes it possible without any difficulties to obtain rolled products with the given cross-section dimensions due to proper selection of single drafting.

  20. Create dynamic charts in Microsoft Office Excel 2007 and beyond

    CERN Document Server

    Scheck, Reinhold

    2009-01-01

    Extend your Excel 2007 skills-and create more-powerful and compelling charts in less time. Guided by an Excel expert, you'll learn how to turn flat, static charts into dynamic solutions-where you can visualize and manipulate data countless ways with a simple mouse click. Get the hands-on practice and examples you need to produce your own, professional-quality results. No programming required! Maximize the impact of your ideas and data! Learn how your design decisions affect perception and comprehensionMatch the right chart type to your communication objectiveVisualize-then build-your solut

  1. Medical Practitioners Act 2007: the increased medical record burden.

    LENUS (Irish Health Repository)

    Byrne, D

    2010-03-01

    New medical record keeping obligations are implemented by the Medical Practitioners Act (2007), effective July 2009. This audit, comprising review of 347 medical entries in 257 charts on one day, investigated compliance with the Act together with the general standard of medical record keeping. The Medical Council requirement was absent all but 3 (0.9%) of entries; there was no unique identifier or signature in 28 (8%) and 135 (39%) of entries respectively. The case for change is discussed.

  2. Laser stripping of relativistic H- ions with practical considerations

    International Nuclear Information System (INIS)

    Tomlin, R.

    1995-12-01

    This paper describes laser stripping of H - ions. Some applications are suggested for HEP including stripping 2GeV ions circulating in an accelerator with radius 75 meters where laser meets ion head on in a three meter interaction region. The paper describes photoionizaton cross section, laser power calculation, and how to generate the 5 micrometer light

  3. The Las Vegas Strip as a Genuinely Invented Global Landscape

    Directory of Open Access Journals (Sweden)

    Daniel Ortega

    2004-12-01

    Full Text Available Las Vegas, Nevada, is typically recognised as a place via a single urban gesture, that gesture being Las Vegas Boulevard, which is more commonly referred to as "The Strip". In constructing a thesis around the theme, "Here or There? Interconnections between the Global and the Local", one cannot ignore the invitation to discuss globalisation and its effects on a particular local fabric. For the purpose of this text, globalisation can be thought of as what Carmona et al describe as an intricate series of events leading to the world "becoming increasingly interconnected, with centralised decision making exploiting economies of scale and standardisation" (2003: 101. The centralised decision-making process for The Strip is evident in the strategy to develop individually themed casino resorts along Las Vegas Boulevard that respond to a competitive economy, thus creating a newly standardised landscape. If we also understand that globalisation can be thought of as the development of an interconnected world where economic, political and cultural boundaries can be easily crossed, this work can begin to define how the Las Vegas Strip is a genuinely invented global landscape. This paper addresses the "here-ness" as well as the "there-ness" of The Strip, while offering a dialectical framework for establishing a meaning of place by having 'there' placed 'here'. By employing semiological interpretations of real landscapes from around the globe (for example, Venturi et al, 1972, The Strip becomes a newly invented landscape of "simulations" (Baudrillard, 1988. As such, The Strip acts as a narrative that forms a unique place, opening the door to questions of authenticity and identity. This paper concludes by focusing on the question of "Here or There?" as an appropriate deviation from the assumed role that the post-modern landscape of the Las Vegas Strip plays. This work is intended to be a point of departure from the frequent criticism of the Las Vegas Strip as

  4. Flexible Faraday Cage with a Twist: Surface Charge on a Mobius Strip

    Science.gov (United States)

    Stewart, Sean

    2007-01-01

    Once an intriguing topological novelty known only to mathematicians, the Mobius strip has become a source of fascination and inspiration to the layperson and artist alike. Principal among its features are the two strange properties that the Mobius strip is a surface with only one side and one edge. A Mobius strip is readily formed by taking a long…

  5. Cartographic Rules and Differences in Nautical Data Visualization on Paper and Electronic Nautical Charts

    Directory of Open Access Journals (Sweden)

    Tea Duplančić Leder

    2013-04-01

    Full Text Available This paper aims to present cartographic rules for the production of paper and electronic navigational charts and main differences in compilation, visualisation and representation of nautical information. Major differences between paper nautical charts and ENC are visualisation of nautical data: colour mixing, resolution of represented nautical objects, human control of display representation and fonts and signatures and chart content are described. It is concluded that electronic navigational charts have many advantages and few shortcomings to paper navigational charts.

  6. Transfer printing of graphene strip from the graphene grown on copper wires

    International Nuclear Information System (INIS)

    Su, Ching-Yuan; Fu Dongliang; Lu, Ang-Yu; Liu, Keng-Ku; Xu Yanping; Juang, Zhen-Yu; Li, Lain-Jong

    2011-01-01

    A simple, cost-effective and lithography-free fabrication of graphene strips for device applications is demonstrated. The graphene thin layers were directly grown on Cu wires, followed by Cu etching and transfer printing to arbitrary substrates by a PDMS stamp. The Cu wires can be arranged on the PDMS stamp in a desired pattern; hence, the substrates can receive graphene strips with the same pattern. Moreover, the preparation of graphene strips does not involve conventional lithography; therefore, the surface of the graphene strip is free of residual photoresists, which may be useful for studies requiring clean graphene surfaces.

  7. Theoretical study of H- stripping with a wiggler magnet

    International Nuclear Information System (INIS)

    Hutson, R.L.

    1991-01-01

    The first step for injecting protons into the LAMPF Proton Storage Ring (PSR) at LANL is to strip a beam of 800-MeV H - ions to H 0 with a 1.8-T dipole magnet. Because of the finite lifetime of energetic H - ions in the magnetic field, their trajectories bend before stripping causing the angular spread of the beam, and therefore its emittance, to grow during the stripping process. In the case of the PSR, the horizontal beam emittance grows by a factor of roughly three during injection. As a consequence, beam losses in the ring are significantly greater than they would be if there were not emittance growth. A speculative technique is proposed in which the beam divergence growth and resulting emittance growth is reduced by stripping the H - in a wiggler magnet whose transverse field alternates in direction as a function of position along the beam axis. The wiggler field configuration is adjusted so that the angular beam spread introduced during passage through one unidirectional-field increment of path is relatively small and so that 99.99% of the beam is stripped after passing through the whole magnet. With careful field design the net added angular beam spread is reduced because the incremental angular spreads are painted back and forth over the same small range. In the hypothetical case described, the calculated emittance growth and beam loss increase are significantly smaller than those calculated for a conventional stripper magnet. 3 refs., 3 figs

  8. Coordinate determination of high energy charged particles by silicon strip detectors

    International Nuclear Information System (INIS)

    Anokhin, I.E.; Zinets, O.S.

    2002-01-01

    The coordinate determination accuracy of minimum ionizing and short-range particles by silicon strip detectors has been considered. The charge collection on neighboring strips of the detector is studied and the influence of diffusion and the electric field distribution on the accuracy of the coordinate determination is analyzed. It has been shown that coordinates of both minimum ionizing and short-range particles can be determined with accuracy to a few microns using silicon strip detectors. 11 refs.; 8 figs

  9. Fabrication of silicon strip detectors using a step-and-repeat lithography system

    International Nuclear Information System (INIS)

    Holland, S.

    1991-11-01

    In this work we describe the use of a step-and-repeat lithography system (stepper) for the fabrication of silicon strip detectors. Although the field size of the stepper is only 20 mm in diameter, we have fabricated much larger detectors by printing a repetitive strip detector pattern in a step-and-repeat fashion. The basic unit cell is 7 mm in length. The stepper employs a laser interferometer for stage placement, and the resulting high precision allows one to accurately place the repetitive patterns on the wafer. A small overlap between the patterns ensures a continuous strip. A detector consisting of 512 strips on a 50 μm pitch has been fabricated using this technique. The dimensions of the detector are 6.3 cm by 2.56 cm. Yields of over 99% have been achieved, where yield is defined as the percentage of strips with reverse leakage current below 1 nA. In addition to the inherent advantages of a step-and-repeat system, this technique offers great flexibility in the fabrication of large-area strip detectors since the length and width of the detector can be changed by simply reprogramming the stepper computer. Hence various geometry strip detectors can be fabricated with only one set of masks, as opposed to a separate set of masks for each geometry as would be required with a contact or proximity aligner

  10. Statistical Control Charts: Performances of Short Term Stock Trading in Croatia

    Directory of Open Access Journals (Sweden)

    Dumičić Ksenija

    2015-03-01

    Full Text Available Background: The stock exchange, as a regulated financial market, in modern economies reflects their economic development level. The stock market indicates the mood of investors in the development of a country and is an important ingredient for growth. Objectives: This paper aims to introduce an additional statistical tool used to support the decision-making process in stock trading, and it investigate the usage of statistical process control (SPC methods into the stock trading process. Methods/Approach: The individual (I, exponentially weighted moving average (EWMA and cumulative sum (CUSUM control charts were used for gaining trade signals. The open and the average prices of CROBEX10 index stocks on the Zagreb Stock Exchange were used in the analysis. The statistical control charts capabilities for stock trading in the short-run were analysed. Results: The statistical control chart analysis pointed out too many signals to buy or sell stocks. Most of them are considered as false alarms. So, the statistical control charts showed to be not so much useful in stock trading or in a portfolio analysis. Conclusions: The presence of non-normality and autocorellation has great impact on statistical control charts performances. It is assumed that if these two problems are solved, the use of statistical control charts in a portfolio analysis could be greatly improved.

  11. A critical review of the hypothesis of a medieval origin for portolan charts

    NARCIS (Netherlands)

    Nicolai, R.

    2014-01-01

    Portolan charts are nautical charts, which appear suddenly in the thirteenth century Mediterranean world, without any discernable development path or predecessors. These charts are remarkable for the high degree of realism and accuracy with which they render the coastlines of their core coverage

  12. Moving strip technique of electron beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Kishio; Wakasa, Hiroyuki; Oguri, Nobuhiro; Kitayama, Takuichi; Nakagiri, Yoshitada; Mikami, Yasutaka; Hashimoto, Keiji; Hiraki, Yoshio; Aono, Kaname

    1984-12-01

    The fieldsize in electron beam therapy is determined by the cone size. In case of skin metastasis of a malignant tumor and so on, which need a large field size and whose area is much larger than the size of the cone, a large field size is usually produced by dividing the portals. However, the dose distribution at the border of the field becomes unequal, and hot and cold dose areas are produced according to the distance between portals. We tried the strip field technique in a large field along the long axis of the body in order to flatten the dose of the border employing the moving strip used for whole abdominal irradiation in ovarian cancer. We set the film in Mix-DP and used the strip field technique with 2.5cm steps. We discussed the relationship between the interval (distance between portals) and the flattening of the dose within the field. Skin movement due to breathing and influences on the flattening of the dose were considered. The proper flatness was obtained at depths of 0,1,2, and 3cm by setting the interval at 0.5cm. When skin movement was produced by breathing in +-1.5mm, the proper flaness was obtained also at a 0.5-cm interval. It seems that smoothing is increased by breathing. An ''electron beam moving strip'' with a 2.5-cm step and 0.5-cm interval was clinically effective in the treatment of patients with skin metastasis of colon cancer. (author).

  13. THz Wave Propagation on Strip Lines: Devices, Properties, and Applications

    Directory of Open Access Journals (Sweden)

    Y. Kadoya

    2008-06-01

    Full Text Available We report the propagation characteristics of THz pulses on micro-strip-lines and coplanar strip-lines, in which low permittivity polymer materials are used as the dielectric layer or the substrate. As a result of the low attenuation and small dispersion in the devices, the spectral width up to 3 THz can be achieved even after the 1 mm propagation. Spectroscopic characterizations of liquid or powder specimens are demonstrated using the devices. We also show a possibility of realizing a very low attenuation using a quadrupole mode in three strip coplanar lines on the polymer substrate.

  14. Improved dielectric functions in metallic films obtained via template stripping

    Science.gov (United States)

    Hyuk Park, Jong; Nagpal, Prashant; Oh, Sang-Hyun; Norris, David J.

    2012-02-01

    We compare the dielectric functions of silver interfaces obtained via thermal evaporation with those obtained with template stripping. Ellipsometry measurements show that the smoother template-stripped surfaces exhibit effective dielectric functions with a more negative real component and a smaller imaginary component, implying higher conductivity and less energy loss, respectively. These results agree with the relation between dielectric function and surface roughness derived from combining the effective-medium model and the Drude-Lorentz model. The improvement in the effective dielectric properties shows that metallic films prepared via template stripping can be favorable for applications in electronics, nanophotonics, and plasmonics.

  15. New technology for the production of magnesium strips and sheets

    Directory of Open Access Journals (Sweden)

    R. Kawalla

    2008-07-01

    Full Text Available A new production technology for magnesium strip, based on twin-roll-casting and strip rolling was developed in Freiberg Germany. By means of this economic method it is possible to produce strips in deep drawing quality with good forming properties in order to satisfy the request for low cost Mg sheets in the automotive and electronic industry. Both, coils as single sheets, were manufactured and rolled to a thickness of 1mm(0,5 mm. The technology of the new process and the properties of the twin-roll-casted material and the final sheets are presented.

  16. Robust control charts in industrial production of olive oil

    Science.gov (United States)

    Grilo, Luís M.; Mateus, Dina M. R.; Alves, Ana C.; Grilo, Helena L.

    2014-10-01

    Acidity is one of the most important variables in the quality analysis and characterization of olive oil. During the industrial production we use individuals and moving range charts to monitor this variable, which is not always normal distributed. After a brief exploratory data analysis, where we use the bootstrap method, we construct control charts, before and after a Box-Cox transformation, and compare their robustness and performance.

  17. 3D silicon strip detectors

    International Nuclear Information System (INIS)

    Parzefall, Ulrich; Bates, Richard; Boscardin, Maurizio; Dalla Betta, Gian-Franco; Eckert, Simon; Eklund, Lars; Fleta, Celeste; Jakobs, Karl; Kuehn, Susanne; Lozano, Manuel; Pahn, Gregor; Parkes, Chris; Pellegrini, Giulio; Pennicard, David; Piemonte, Claudio; Ronchin, Sabina; Szumlak, Tomasz; Zoboli, Andrea; Zorzi, Nicola

    2009-01-01

    While the Large Hadron Collider (LHC) at CERN has started operation in autumn 2008, plans for a luminosity upgrade to the Super-LHC (sLHC) have already been developed for several years. This projected luminosity increase by an order of magnitude gives rise to a challenging radiation environment for tracking detectors at the LHC experiments. Significant improvements in radiation hardness are required with respect to the LHC. Using a strawman layout for the new tracker of the ATLAS experiment as an example, silicon strip detectors (SSDs) with short strips of 2-3 cm length are foreseen to cover the region from 28 to 60 cm distance to the beam. These SSD will be exposed to radiation levels up to 10 15 N eq /cm 2 , which makes radiation resistance a major concern for the upgraded ATLAS tracker. Several approaches to increasing the radiation hardness of silicon detectors exist. In this article, it is proposed to combine the radiation hard 3D-design originally conceived for pixel-style applications with the benefits of the established planar technology for strip detectors by using SSDs that have regularly spaced doped columns extending into the silicon bulk under the detector strips. The first 3D SSDs to become available for testing were made in the Single Type Column (STC) design, a technological simplification of the original 3D design. With such 3D SSDs, a small number of prototype sLHC detector modules with LHC-speed front-end electronics as used in the semiconductor tracking systems of present LHC experiments were built. Modules were tested before and after irradiation to fluences of 10 15 N eq /cm 2 . The tests were performed with three systems: a highly focused IR-laser with 5μm spot size to make position-resolved scans of the charge collection efficiency, an Sr 90 β-source set-up to measure the signal levels for a minimum ionizing particle (MIP), and a beam test with 180 GeV pions at CERN. This article gives a brief overview of the results obtained with 3D-STC-modules.

  18. 3D silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parzefall, Ulrich [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany)], E-mail: ulrich.parzefall@physik.uni-freiburg.de; Bates, Richard [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Boscardin, Maurizio [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Dalla Betta, Gian-Franco [INFN and Universita' di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Eckert, Simon [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Eklund, Lars; Fleta, Celeste [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Jakobs, Karl; Kuehn, Susanne [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Lozano, Manuel [Instituto de Microelectronica de Barcelona, IMB-CNM, CSIC, Barcelona (Spain); Pahn, Gregor [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); Parkes, Chris [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Pellegrini, Giulio [Instituto de Microelectronica de Barcelona, IMB-CNM, CSIC, Barcelona (Spain); Pennicard, David [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Piemonte, Claudio; Ronchin, Sabina [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy); Szumlak, Tomasz [University of Glasgow, Department of Physics and Astronomy, Glasgow G12 8QQ (United Kingdom); Zoboli, Andrea [INFN and Universita' di Trento, via Sommarive 14, 38050 Povo di Trento (Italy); Zorzi, Nicola [FBK-irst, Center for Materials and Microsystems, via Sommarive 18, 38050 Povo di Trento (Italy)

    2009-06-01

    While the Large Hadron Collider (LHC) at CERN has started operation in autumn 2008, plans for a luminosity upgrade to the Super-LHC (sLHC) have already been developed for several years. This projected luminosity increase by an order of magnitude gives rise to a challenging radiation environment for tracking detectors at the LHC experiments. Significant improvements in radiation hardness are required with respect to the LHC. Using a strawman layout for the new tracker of the ATLAS experiment as an example, silicon strip detectors (SSDs) with short strips of 2-3 cm length are foreseen to cover the region from 28 to 60 cm distance to the beam. These SSD will be exposed to radiation levels up to 10{sup 15}N{sub eq}/cm{sup 2}, which makes radiation resistance a major concern for the upgraded ATLAS tracker. Several approaches to increasing the radiation hardness of silicon detectors exist. In this article, it is proposed to combine the radiation hard 3D-design originally conceived for pixel-style applications with the benefits of the established planar technology for strip detectors by using SSDs that have regularly spaced doped columns extending into the silicon bulk under the detector strips. The first 3D SSDs to become available for testing were made in the Single Type Column (STC) design, a technological simplification of the original 3D design. With such 3D SSDs, a small number of prototype sLHC detector modules with LHC-speed front-end electronics as used in the semiconductor tracking systems of present LHC experiments were built. Modules were tested before and after irradiation to fluences of 10{sup 15}N{sub eq}/cm{sup 2}. The tests were performed with three systems: a highly focused IR-laser with 5{mu}m spot size to make position-resolved scans of the charge collection efficiency, an Sr{sup 90}{beta}-source set-up to measure the signal levels for a minimum ionizing particle (MIP), and a beam test with 180 GeV pions at CERN. This article gives a brief overview of

  19. Bimetallic strip for low temperature use. [4-300/sup 0/K

    Science.gov (United States)

    Bussiee, J.F.; Welch, D.O.; Suenaga, M.

    A class of mechanically pre-stressed structures is provided suitably bi-layer strips, consisting of a layer of group 5 transition metals in intimate contact with a layer of an intermetallic compound of transition metals with certain group 3A, 4A or 5A metals or metalloids such as Ga, In, Si, Ge, Sn, As or Sb. The changes of Young's modulus of these bi-layered combinations at temperatures in the region of somewhat above absolute zero provides a useful means of sensing temperature changes. Such bi-metallic strips may be used as control strips in thermostats, or in direct dial reading instruments. The structures are made by preparing a sandwich of a group 5B transition metal strip between the substantially thicker strips of an alloy between copper and a predetermined group 3A, 4A or 5A metal or metalloid, holding the three layers are heated, cooled the copper alloys and is removed. Removing one of the two formed interlayer alloys between the transition metal and the metal previously alloyed with copper remain.

  20. Buffer Strips for Riparian Zone Management

    National Research Council Canada - National Science Library

    1991-01-01

    This study provides a review of technical literature concerning the width of riparian buffer strips needed to protect water quality and maintain other important values provided by riparian ecosystem...

  1. Monitoring Compliance to Promote Quality Assurance: Development of a Mental Health Clinical Chart Audit Tool in Belize, 2013.

    Science.gov (United States)

    Winer, Rachel A; Bennett, Eleanor; Murillo, Illouise; Schuetz-Mueller, Jan; Katz, Craig L

    2015-09-01

    Belize trained psychiatric nurse practitioners (PNPs) in the early 1990s to provide mental health services throughout the country. Despite overwhelming success, the program is limited by lack of monitoring, evaluation, and surveillance. To promote quality assurance, we developed a chart audit tool to monitor mental healthcare delivery compliance for initial psychiatric assessment notes completed by PNPs. After reviewing the Belize Health Information System electronic medical record system, we developed a clinical audit tool to capture 20 essential components for initial assessment clinical notes. The audit tool was then piloted for initial assessment notes completed during July through September of 2013. One hundred and thirty-four initial psychiatric interviews were audited. The average chart score among all PNPs was 9.57, ranging from 3 to 15. Twenty-three charts-or 17.2%-had a score of 14 or higher and met a 70% compliance benchmark goal. Among indicators most frequently omitted included labs ordered and named (15.7%) and psychiatric diagnosis (21.6%). Explicit statement of medications initiated with dose and frequency occurred in 47.0% of charts. Our findings provide direction for training and improvement, such as emphasizing the importance of naming labs ordered, medications and doses prescribed, and psychiatric diagnoses in initial assessment clinical notes. We hope this initial assessment helps enhance mental health delivery compliance by prompting creation of BHIS templates, development of audits tools for revisit follow-up visits, and establishment of corrective actions for low-scoring practitioners. These efforts may serve as a model for implementing quality assurance programming in other low resource settings.

  2. L-strip proximity fed ga

    Directory of Open Access Journals (Sweden)

    Ashish Singh

    2014-03-01

    Full Text Available In this article, the analysis of dualband L-strip fed compact semi-circular disk microstrip patch antenna has been presented using circuit theory concept. The antenna parameters such as return loss, VSWR and radiation pattern are calculated. The effect of geometric dimensions of the proposed antenna such as length of vertical and horizontal portion of L-strip is investigated. It is found that antenna resonate at two distinct modes i.e. 1.3 GHz and 6.13 GHz for lower and upper resonance frequencies respectively. The bandwidth of the proposed antenna at lower resonance frequency is 6.61% (simulated and 10.64% (theoretical whereas at upper resonance frequency, it is 6.02% (simulated and 9.06 % (theoretical. The theoretical results are compared with IE3D simulation results as well as experimental results and they are in close agreement.

  3. On the Formation of Ultra-Difuse Galaxies as Tidally-Stripped Systems

    Science.gov (United States)

    Carleton, Timothy; Cooper, Michael; Kaplinghat, Manoj; Errani, Raphael; Penarrubia, Jorge

    2018-01-01

    The recent identification of a large population of so-called 'Ultra-Diffuse' Galaxies (UDGs), with stellar masses ~108 M⊙, but half light radii over 1.5 kpc, has challenged our understanding of galaxy evolution. Motivated by the environmental dependence of UDG properties and abundance, I present a model for the formation of UDGs through tidal-stripping of dwarf galaxies in cored dark matter halos. To test this scenario, I utilize results from simulations of tidal stripping, which demonstrate that changes in the stellar profile of a tidally stripped galaxy can be written as a function of the amount of tidal stripping experienced by the halo (tidal tracks). These tracks, however, are different for cored and cuspy halos. Additional simulations show how the halo responds to tidal interactions given the halo orbit within a cluster.In particular, dwarf elliptical galaxies, born in 1010-10.5 M⊙ halos, expand significantly as a result of tidal stripping and produce UDGs. Applying these models to the population of halos in the Bolshoi simulation, I am able to follow the effects of tidal stripping on the dwarf galaxy population in clusters. Using tidal tracks for cuspy halos does not reproduce the observed properties of UDGs. However, using the tidal tracks for cored halos, I reproduce the distribution of sizes, stellar masses, and abundance of UDGs in clusters remarkably well.

  4. Dynamic probability control limits for risk-adjusted CUSUM charts based on multiresponses.

    Science.gov (United States)

    Zhang, Xiang; Loda, Justin B; Woodall, William H

    2017-07-20

    For a patient who has survived a surgery, there could be several levels of recovery. Thus, it is reasonable to consider more than two outcomes when monitoring surgical outcome quality. The risk-adjusted cumulative sum (CUSUM) chart based on multiresponses has been developed for monitoring a surgical process with three or more outcomes. However, there is a significant effect of varying risk distributions on the in-control performance of the chart when constant control limits are applied. To overcome this disadvantage, we apply the dynamic probability control limits to the risk-adjusted CUSUM charts for multiresponses. The simulation results demonstrate that the in-control performance of the charts with dynamic probability control limits can be controlled for different patient populations because these limits are determined for each specific sequence of patients. Thus, the use of dynamic probability control limits for risk-adjusted CUSUM charts based on multiresponses allows each chart to be designed for the corresponding patient sequence of a surgeon or a hospital and therefore does not require estimating or monitoring the patients' risk distribution. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  5. MO-A-BRB-02: Considerations and Issues in Electronic Charting for Brachytherapy

    International Nuclear Information System (INIS)

    Richardson, S.

    2015-01-01

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy

  6. SU-F-T-96: A New Paradigm of Weekly Chart Checking for Radiation Therapy Clinics

    International Nuclear Information System (INIS)

    Tan, J; Pompos, A; Jiang, S; Yan, Y

    2016-01-01

    Purpose: To put forth an innovative clinical paradigm for weekly chart checking so that treatment status is periodically checked accurately and efficiently. This study also aims to help optimize the chart checking clinical workflow in a busy radiation therapy clinic. Methods: It is mandated by the Texas Administrative code to check patient charts of radiation therapy once a week or every five fractions, however it varies drastically among institutions in terms of when and how it is done. Some do it every day, but a lot of efforts are wasted on opening ineligible charts; some do it on a fixed day but the distribution of intervals between subsequent checks is not optimal. To establish an optimal chart checking procedure, a new paradigm was developed to achieve 1) charts are checked more accurately and more efficiently; 2) charts are checked on optimal days without any miss; 3) workload is evened out throughout a week when multiple physicists are involved. All active charts will be accessed by querying the R&V system. Priority is assigned to each chart based on the number of days before the next due date followed by sorting and workload distribution steps. New charts are also taken into account when distributing the workload so it is reasonably even throughout the week. Results: Our clinical workflow became more streamlined and smooth. In addition, charts get checked in a more timely fashion so that errors would get caught earlier should they occur. Conclusion: We developed a new weekly chart checking diagram. It helps physicists check charts in a timely manner, saves their time in busy clinics, and consequently reduces possible errors.

  7. SU-F-T-96: A New Paradigm of Weekly Chart Checking for Radiation Therapy Clinics

    Energy Technology Data Exchange (ETDEWEB)

    Tan, J; Pompos, A; Jiang, S; Yan, Y [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: To put forth an innovative clinical paradigm for weekly chart checking so that treatment status is periodically checked accurately and efficiently. This study also aims to help optimize the chart checking clinical workflow in a busy radiation therapy clinic. Methods: It is mandated by the Texas Administrative code to check patient charts of radiation therapy once a week or every five fractions, however it varies drastically among institutions in terms of when and how it is done. Some do it every day, but a lot of efforts are wasted on opening ineligible charts; some do it on a fixed day but the distribution of intervals between subsequent checks is not optimal. To establish an optimal chart checking procedure, a new paradigm was developed to achieve 1) charts are checked more accurately and more efficiently; 2) charts are checked on optimal days without any miss; 3) workload is evened out throughout a week when multiple physicists are involved. All active charts will be accessed by querying the R&V system. Priority is assigned to each chart based on the number of days before the next due date followed by sorting and workload distribution steps. New charts are also taken into account when distributing the workload so it is reasonably even throughout the week. Results: Our clinical workflow became more streamlined and smooth. In addition, charts get checked in a more timely fashion so that errors would get caught earlier should they occur. Conclusion: We developed a new weekly chart checking diagram. It helps physicists check charts in a timely manner, saves their time in busy clinics, and consequently reduces possible errors.

  8. Approaching total absorption of graphene strips using a c-Si subwavelength periodic membrane

    Science.gov (United States)

    Sang, Tian; Wang, Rui; Li, Junlang; Zhou, Jianyu; Wang, Yueke

    2018-04-01

    Approaching total absorption of graphene strips at near infrared using a crystalline-silicon (c-Si) subwavelength periodic membrane (SPM) is presented. The absorption in graphene strips in a c-Si SPM is enhanced by a resonant tip, which is resulted from the coupling between the guided mode and the radiation mode through symmetry breaking of the structure at near-normal incidence. The enhancement of the electric field intensity is increased 1939 times and the group velocity of light is decreased to 3.55 ×10-4c at resonance, and 99.3% absorption in graphene strips can be achieved by critical coupling at the incident angle of 2°. High absorption of the graphene strips can be maintained as the etching thickness, the strip width, and the period are altered. When this type of c-Si SPM with graphene strips is used in refractive index sensors, it shows excellent sensing properties due to its stable near-unity absorption.

  9. Ammonia removal from landfill leachate by air stripping and absorption.

    Science.gov (United States)

    Ferraz, Fernanda M; Povinelli, Jurandyr; Vieira, Eny Maria

    2013-01-01

    An old landfill leachate was pre-treated in a pilot-scale aerated packed tower operated in batch mode for total ammoniacal nitrogen (TAN) removal. The stripped ammonia was recovered with a 0.4 mol L(-1) H2SO4 solution, deionized water and tap water. Ca(OH)2 (95% purity) or commercial hydrated lime was added to the raw leachate to adjust its pH to 11, causing removal of colour (82%) and heavy metals (70-90% for Zn, Fe and Mn). The 0.4 molL(-1) H2SO4 solution was able to neutralize 80% of the stripped ammonia removed from 12 L of leachate. The effectiveness of the neutralization of ammonia with deionized water was 75%. Treating 100 L of leachate, the air stripping tower removed 88% of TAN after 72 h of aeration, and 87% of the stripped ammonia was recovered in two 31 L pilot-scale absorption units filled with 20 L of tap water.

  10. The New Silicon Strip Detectors for the CMS Tracker Upgrade

    CERN Document Server

    Dragicevic, Marko

    2010-01-01

    The first introductory part of the thesis describes the concept of the CMS experiment. The tasks of the various detector systems and their technical implementations in CMS are explained. To facilitate the understanding of the basic principles of silicon strip sensors, the subsequent chapter discusses the fundamentals in semiconductor technology, with particular emphasis on silicon. The necessary process steps to manufacture strip sensors in a so-called planar process are described in detail. Furthermore, the effects of irradiation on silicon strip sensors are discussed. To conclude the introductory part of the thesis, the design of the silicon strip sensors of the CMS Tracker are described in detail. The choice of the substrate material and the complex geometry of the sensors are reviewed and the quality assurance procedures for the production of the sensors are presented. Furthermore the design of the detector modules are described. The main part of this thesis starts with a discussion on the demands on the ...

  11. Digital simulation of anodic stripping voltammetry from thin film electrodes

    International Nuclear Information System (INIS)

    Magallanes, J.F.

    1984-01-01

    The anodic stripping voltammetry (ASV) is routinely applied to control of Cu(II) in heavy water in the primary cooling loop of the Nuclear Power Reactor. The anodic stripping voltammetry (ASV) is a very well-known technique in electroanalytical chemistry. However, due to the complexity of the phenomena, it is practised with the fundamentals of empiric considerations. A geometric model for the anodic stripping voltammetry (ASV) from thin film electrodes which can be calculated by explicit digital simulation method is proposed as a possibility of solving the electrochemically reversible, cuasi-reversible and irreversible reactions under linear potential scan and multiple potential scans. (Until now the analytical mathematical method was applied to reversible reactions). All the results are compared with analytical solutions and experimental results and it permits to conclude that the anodic stripping voltammetry (ASV) can be studied with the simplicity and potentialities of explicit digital simulation methods. (M.E.L.) [es

  12. Nuclear industry chart no. 21 - France

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    A fold-out chart shows the relationship between the government bodies and industrial concerns. Nuclear power plant orders under the 1970-84 programme are tabulated. A directory is included of national bodies, firms and establishments. (U.K.)

  13. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  14. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  15. Engineering test of stripping performance by multi-centrifugal contactors system for spent nuclear reprocessing

    International Nuclear Information System (INIS)

    Masayuki Takeuchi; Tadahiro Washiya; Hiroki Nakabayashi; Takashi Suganuma; Shinnichi Aose

    2005-01-01

    Japan Nuclear Cycle Development Institute (JNC) has been developing centrifugal contactors which are compact and high performance for solvent extraction process in industrial reprocessing plant. The stripping performance including equilibrium time for distribution and hydraulic behavior of the multi-centrifugal contactors were mainly evaluated by using uranium nitrite solution on engineering scale (10 kgHM/hr). In particular, the effects of feed temperature of stripping solution and O/A on the stripping performance were focused in this test. As results, no hydraulic problem such as overflow and entrainment were observed in multi-centrifugal contactors system through all conditions, and the uranium and acid concentrations showed desirable profiles which were nearly consistent with calculated one by MIXSET-X code. As to stripping performance, uranium leak concentration in solvent reached to less than 0.01 g/L, which is target of the stripping performance on this centrifugal contactors system, within nine stages on all conditions. It was also found that the effect of feed temperature of stripping solution (35 degree C → 60 degree C) or O/A (1.0→0.8) on stripping performance corresponds to distribution capacity of two contactors, respectively. The stage efficiency for a contactor was estimated as 97-98% on stripping stage. There were no uranium leaks (less than 40μg/L) in spent solvent discharged from the final stage. The profiles of uranium concentration in multi-contactors become stable within 10 minutes after the stripping test starting. In this way, it was demonstrated that the centrifugal contactors system has good stripping performance on engineering scale. (authors)

  16. Adsorptive stripping voltammetric methods for determination of aripiprazole

    Directory of Open Access Journals (Sweden)

    Derya Aşangil

    2012-06-01

    Full Text Available Anodic behavior of aripiprazole (ARP was studied using electrochemical methods. Charge transfer, diffusion and surface coverage coefficients of adsorbed molecules and the number of electrons transferred in electrode mechanisms were calculated for quasi-reversible and adsorption-controlled electrochemical oxidation of ARP at 1.15 V versus Ag/AgCl at pH 4.0 in Britton–Robinson buffer (BR on glassy carbon electrode. Voltammetric methods for direct determination of ARP in pharmaceutical dosage forms and biological samples were developed. Linearity range is found as from 11.4 μM (5.11 mg/L to 157 μM (70.41 mg/L without stripping mode and it is found as from 0.221 μM (0.10 mg/L to 13.6 μM (6.10 mg/L with stripping mode. Limit of detection (LOD was found to be 0.11 μM (0.05 mg/L in stripping voltammetry. Methods were successfully applied to assay the drug in tablets, human serum and human urine with good recoveries between 95.0% and 104.6% with relative standard deviation less than 10%. Keywords: Adsorptive stripping voltammetry, Aripiprazole, Electrochemical behavior, Human serum and urine, Pharmaceuticals

  17. Strip-till seeder for sugar beets

    Directory of Open Access Journals (Sweden)

    Peter Schulze Lammers

    2014-06-01

    Full Text Available Strip-till save costs by reducing tillage on the area of sugar beet rows only. The seeding system is characterized by a deep loosening of soil with a tine combined with a share and by following tools generating fine-grained soil as seed bed. In cooperation with the Kverneland company group Soest/Germany a strip tiller combined with precision seeder was designed and tested in field experiments. Tilling and seeding was performed in one path on fields with straw and mustard mulch. Even the plant development was slower as compared to conventional sawn sugar beets the yield was on equivalent level. Further field experiments are planned to attest constant yield, cost and energy efficiency of the seeding system.

  18. Synchrotron applications of pixel and strip detectors at Diamond Light Source

    International Nuclear Information System (INIS)

    Marchal, J.; Tartoni, N.; Nave, C.

    2009-01-01

    A wide range of position-sensitive X-ray detectors have been commissioned on the synchrotron X-ray beamlines operating at the Diamond Light Source in UK. In addition to mature technologies such as image-plates, CCD-based detectors, multi-wire and micro-strip gas detectors, more recent detectors based on semiconductor pixel or strip sensors coupled to CMOS read-out chips are also in use for routine synchrotron X-ray diffraction and scattering experiments. The performance of several commercial and developmental pixel/strip detectors for synchrotron studies are discussed with emphasis on the image quality achieved with these devices. Examples of pixel or strip detector applications at Diamond Light Source as well as the status of the commissioning of these detectors on the beamlines are presented. Finally, priorities and ideas for future developments are discussed.

  19. A COMPARISON OF SOME ROBUST BIVARIATE CONTROL CHARTS FOR INDIVIDUAL OBSERVATIONS

    Directory of Open Access Journals (Sweden)

    Moustafa Omar Ahmed Abu - Shawiesh

    2014-06-01

    Full Text Available This paper proposed and considered some bivariate control charts to monitor individual observations from a statistical process control. Usual control charts which use mean and variance-covariance estimators are sensitive to outliers. We consider the following robust alternatives to the classical Hoteling's T2: T2MedMAD, T2MCD, T2MVE a simulation study has been conducted to compare the performance of these control charts. Two real life data are analyzed to illustrate the application of these robust alternatives.

  20. News from the Library: The 8th edition Karlsruhe nuclide chart has been released

    CERN Multimedia

    CERN Library

    2012-01-01

    The 8th edition of the Karlsruhe Nuclide Chart contains new data not found in the 7th edition.   Since 1958, the well-known Karlsruhe Nuclide Chart has provided scientists with structured, valuable information on the half-lives, decay modes and energies of radioactive nuclides. The chart is used in many disciplines in physics (health physics, radiation protection, nuclear and radiochemistry, astrophysics, etc.) but also in the life and earth sciences (biology, medicine, agriculture, geology, etc.). The 8th edition of the Karlsruhe Nuclide Chart contains new data on 737 nuclides not found in the 7th edition. In total, nuclear data on 3847 experimentally observed ground states and isomers are presented. A new web-based version of this chart is in the final stages of development for use within the Nucleonica Nuclear Science Portal - a portal for which CERN has an institutional license. The chart is also available in paper format.   If you want to buy a paper version of the chart, ple...

  1. Handbook of thermodynamic tables and charts

    International Nuclear Information System (INIS)

    Raznjevic, K.

    1976-01-01

    A compilation of thermodynamic and thermophysical tables and charts is presented. Numerical values are cited in both technical and SI units. Solid, liquid, vapor, and gaseous forms of organic and inorganic materials are included. 12 figures, 137 tables

  2. Candlestick Charting and Trading Volume: Evidence from Bursa Malaysia

    OpenAIRE

    Chin, Chee-Ling; Jais, Mohamad; Balia, Sophee Sulong; Ahmad, Ayoib Che; Abidin, Azlan Zainol

    2016-01-01

    Technical analysis is deemed to be a futile practice among academicians who propose efficient market hypothesis, typically the weak form market efficiency which strongly protests the application of past prices and trading volume data for prediction of future market movement. As candlestick charting is one of the oldest technical indicators for short term investment, therefore this study examines the predictability of candlestick charting with combination to trading volume for Malaysian stock ...

  3. Impact of Scribes on Physician Satisfaction, Patient Satisfaction, and Charting Efficiency: A Randomized Controlled Trial.

    Science.gov (United States)

    Gidwani, Risha; Nguyen, Cathina; Kofoed, Alexis; Carragee, Catherine; Rydel, Tracy; Nelligan, Ian; Sattler, Amelia; Mahoney, Megan; Lin, Steven

    2017-09-01

    Scribes are increasingly being used in clinical practice despite a lack of high-quality evidence regarding their effects. Our objective was to evaluate the effect of medical scribes on physician satisfaction, patient satisfaction, and charting efficiency. We conducted a randomized controlled trial in which physicians in an academic family medicine clinic were randomized to 1 week with a scribe then 1 week without a scribe for the course of 1 year. Scribes drafted all relevant documentation, which was reviewed by the physician before attestation and signing. In encounters without a scribe, the physician performed all charting duties. Our outcomes were physician satisfaction, measured by a 5-item instrument that included physicians' perceptions of chart quality and chart accuracy; patient satisfaction, measured by a 6-item instrument; and charting efficiency, measured by time to chart close. Scribes improved all aspects of physician satisfaction, including overall satisfaction with clinic (OR = 10.75), having enough face time with patients (OR = 3.71), time spent charting (OR = 86.09), chart quality (OR = 7.25), and chart accuracy (OR = 4.61) (all P values patient satisfaction. Scribes increased the proportion of charts that were closed within 48 hours (OR =1.18, P =.028). To our knowledge, we have conducted the first randomized controlled trial of scribes. We found that scribes produced significant improvements in overall physician satisfaction, satisfaction with chart quality and accuracy, and charting efficiency without detracting from patient satisfaction. Scribes appear to be a promising strategy to improve health care efficiency and reduce physician burnout. © 2017 Annals of Family Medicine, Inc.

  4. Neuroprotective effect of Zhen Tian Wan on pial strip-induced ...

    African Journals Online (AJOL)

    ZTW significantly reduced the level of free radicals in pial stripped rats. ZTW can improve learning and memory function and it possess anti-oxidant activity. ZTW may be beneficial in the treatment of vascular dementia. Keywords: Zhen Tian Wan; pial strip; lesion; Memory; Morris water maze; free radicals ...

  5. Scaling of ammonia stripping towers in the treatment of groundwater polluted by municipal solid waste landfill leachate: study of the causes of scaling and its effects on stripping performance

    Directory of Open Access Journals (Sweden)

    Paolo Viotti

    2015-04-01

    Full Text Available This paper documents the causes of the scaling of stripping towers used for the treatment of groundwater polluted by the leachate from an old municipal solid waste (MSW landfill in northern Italy. The effects of the scaling on the stripping performance are also reported. The whole process consists of a coagulation-flocculation pre-treatment at pH > 11, followed by an ammonia stripping stage, after heating the water to 38°C in order to improve removal efficiency. The stripped ammonia is recovered by absorption with sulfuric acid, producing a 30% solution of ammonium sulfate (reused as a base fertilizer. The effluent air stream is recirculated to the stripping towers (closed loop systems in order to avoid an excessive temperature drop inside the packings, mainly in winter, with consequent loss of efficiency and risk of icing. The progressive scaling of the packing has resulted in a loss of ammonia removal efficiency from an initial value of 98% (clean packing down to 80% after six months of continuous operation, necessitating a chemical cleaning. Optimum conditions for design and operation of the stripping process are also documented.

  6. An analysis of stripping to isolated analog resonances

    International Nuclear Information System (INIS)

    Pessoa, E.F.; Toledo Piza, A.F.R. de.

    1983-04-01

    The Feshbach projection formalism is used to calculate the form factors for the (d,n) stripping process to isolated analog resonances. These are used in a standard DWBA stripping calculation in which the radial integration over all space is accomplished by including outerspace contributions evaluated along the complex contours of Vincent and Fortune. It turns out that the shape and magnitude of the predicted cross section is quite insensitive to the continuum proton wave emanating from the resonant residual state. (Author) [pt

  7. Reliability of FAMACHA© chart for the evaluation of anaemia in ...

    African Journals Online (AJOL)

    The reliability of FAMACHA© chart for identifying anaemic goats was compared with Packed Cell Volume (PCV). The colour of the lower eyelids was graded with FAMACHA© chart based on FAMACHA© scores (FS) of 1-5. The animals were scored from severely anaemic (white or FS 5) through moderately anaemic (pink or ...

  8. Study of surface properties of ATLAS12 strip sensors and their radiation resistance

    Energy Technology Data Exchange (ETDEWEB)

    Mikestikova, M., E-mail: mikestik@fzu.cz [Academy of Sciences of the Czech Republic, Institute of Physics, Na Slovance 2, 18221 Prague 8 (Czech Republic); Allport, P.P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J.P.; Wilson, J.A. [School of Physics and Astronomy, University of Birmingham, Birmingham B15 2TT (United Kingdom); Kierstead, J.; Kuczewski, P.; Lynn, D. [Brookhaven National Laboratory, Physics Department and Instrumentation Division, Upton, NY 11973-5000 (United States); Hommels, L.B.A. [Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Ullan, M. [Centro Nacional de Microelectronica (IMB-CNM, CSIC), Campus UAB-Bellaterra, 08193 Barcelona (Spain); Bloch, I.; Gregor, I.M.; Tackmann, K. [DESY, Notkestrasse 85, 22607 Hamburg (Germany); Hauser, M.; Jakobs, K.; Kuehn, S. [Physikalisches Institut, Universität Freiburg, Hermann-Herder-Str. 3, D-79104 Freiburg (Germany); and others

    2016-09-21

    A radiation hard n{sup +}-in-p micro-strip sensor for the use in the Upgrade of the strip tracker of the ATLAS experiment at the High Luminosity Large Hadron Collider (HL-LHC) has been developed by the “ATLAS ITk Strip Sensor collaboration” and produced by Hamamatsu Photonics. Surface properties of different types of end-cap and barrel miniature sensors of the latest sensor design ATLAS12 have been studied before and after irradiation. The tested barrel sensors vary in “punch-through protection” (PTP) structure, and the end-cap sensors, whose stereo-strips differ in fan geometry, in strip pitch and in edge strip ganging options. Sensors have been irradiated with proton fluences of up to 1×10{sup 16} n{sub eq}/cm{sup 2}, by reactor neutron fluence of 1×10{sup 15} n{sub eq}/cm{sup 2} and by gamma rays from {sup 60}Co up to dose of 1 MGy. The main goal of the present study is to characterize the leakage current for micro-discharge breakdown voltage estimation, the inter-strip resistance and capacitance, the bias resistance and the effectiveness of PTP structures as a function of bias voltage and fluence. It has been verified that the ATLAS12 sensors have high breakdown voltage well above the operational voltage which implies that different geometries of sensors do not influence their stability. The inter-strip isolation is a strong function of irradiation fluence, however the sensor performance is acceptable in the expected range for HL-LHC. New gated PTP structure exhibits low PTP onset voltage and sharp cut-off of effective resistance even at the highest tested radiation fluence. The inter-strip capacitance complies with the technical specification required before irradiation and no radiation-induced degradation was observed. A summary of ATLAS12 sensors tests is presented including a comparison of results from different irradiation sites. The measured characteristics are compared with the previous prototype of the sensor design, ATLAS07. - Highlights:

  9. AIS/DOE Technology Roadmap Program: Strip Casting: Anticipating New Routes To Steel Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Prof. Alan W. Camb; Prof. Anthony Rollett

    2001-08-31

    To determine the potential for strip casting in the steel industry and to develop the fundamental knowledge necessary to allow the role of strip casting in the modern steel industry to be understood. Based upon a study of carbon steel strip castings that were either produced for the program at British Steel or were received from a pre-commercial production machine, the following conclusions were made. Strip casting of carbon steels is technically feasible for sheet material from slightly less than 1 mm thick to 3 mm thick, and, assuming that it is economically viable, it will be first applied in carbon steel markets that do not require stringent surface quality or extensive forming. The potential of strip casting as a casting process to be developed for steel castings is very high as the cast strip has some very novel characteristics. Direct cast carbon strip has better surface quality, shape and profile than any other casting process currently available. The more rapidly solidified structure of direct cast strip tends to be strong with low ductility; however, with adequate thermal treatment, it is possible to develop a variety of properties from the same grade. The process is more amenable at this time to production tonnages per year of the order of 500,000 tons and as such will first find niche type applications. This technology is an additional technology for steel production and will be in addition to, rather than a replacement for, current casting machines.

  10. Effect of stimulation intensity and botulinum toxin isoform on rat bladder strip contractions.

    Science.gov (United States)

    Smith, Christopher P; Boone, Timothy B; de Groat, William C; Chancellor, Michael B; Somogyi, George T

    2003-07-15

    The present experiments compared the inhibitory effects of botulinum toxin A (BoNT-A) and botulinum toxin D (BoNT-D) on neurally evoked contractions of rat bladder strips. We examined the effect of fatigue (trains of 100 shocks at 20Hz every 20s for 10min) followed by non-fatigue stimulation (trains of 100 shocks at 20Hz every 100s for 20min) on the onset of effect and potency of the two toxins. For non-fatigue experiments, strips were untreated (n=4); or incubated with 1.36nM BoNT-A (n=4). During fatigue experiments, strips were untreated (n=5); or treated with either 1.36nM BoNT-A (n=6) or 0.8nM BoNT-D (n=6). In non-fatigue experiments, BoNT-A produced significant decreases in contractile area after 1h of stimulation compared to untreated strips (PD bladder strips, were statistically significant (PD-treated strips, as a significant reduction (PD) and untreated bladder strips responded similarly to atropine, suggesting that the effects of BoNT result from inhibition of both acetylcholine and ATP release. Our results demonstrate that BoNT-D may be a more effective agent to inhibit transmitter release from autonomic nerves of the rat lower urinary tract. Moreover, in our hands, non-fatigue stimulation is as effective as fatigue stimulation in inhibiting bladder strip contractions.

  11. Toward a New Brewing Control Chart for the 21st Century.

    Science.gov (United States)

    Melrose, John; Roman-Corrochano, Borja; Montoya-Guerra, Marcela; Bakalis, Serafim

    2018-04-23

    This paper describes new results from a base model of brewing from a bed of packed coffee grains. The model solves for the diffusion of soluble species out of a distribution of particles into the flow through the bed pore space. It requires a limited set of input parameters. It gives a simple picture of the basic physics of coffee brewing and sets out a set of reduced variables for this process. The importance of bed extraction efficiency is elucidated. A coffee brewing control chart has been widely used to describe the region of ideal coffee brewing for some 50 years. A new chart is needed, however, one that connects actual brewing conditions (weight, flow rate, brew time, grind, etc.) to the yield and strength of brews. The paper shows a new approach to brewing control charts, including brew time and bed extraction efficiency as control parameters. Using the base model, an example chart will be given for a particular grind ratio of coarse to fine particles, and an "espresso regime" will be picked out. From such a chart yield, volume and strength of a brew can be read off at will.

  12. Application of machine learning and expert systems to Statistical Process Control (SPC) chart interpretation

    Science.gov (United States)

    Shewhart, Mark

    1991-01-01

    Statistical Process Control (SPC) charts are one of several tools used in quality control. Other tools include flow charts, histograms, cause and effect diagrams, check sheets, Pareto diagrams, graphs, and scatter diagrams. A control chart is simply a graph which indicates process variation over time. The purpose of drawing a control chart is to detect any changes in the process signalled by abnormal points or patterns on the graph. The Artificial Intelligence Support Center (AISC) of the Acquisition Logistics Division has developed a hybrid machine learning expert system prototype which automates the process of constructing and interpreting control charts.

  13. Silicon Strip Detectors for ATLAS at the HL-LHC Upgrade

    CERN Document Server

    Hara, K; The ATLAS collaboration

    2012-01-01

    present ATLAS silicon strip tracker (SCT) and transition radiation tracker(TRT) are to be replaced with new silicon strip detectors as part of the Inner Tracker System (ITK) for the Phase-II upgrade of the Large Hadron Collider, HL-LHC. We have carried out intensive R&D programs based on n+-on-p microstrip detectors to fabricate improved radiation hard strip detectors that can survive the radiation levels corresponding to the integrated luminosity of up to 3000 fb−1. We describe the main specifications for this year’s sensor fabrication and the related R&D results, followed by a description of the candidate schema for module integration.

  14. Distillation and Air Stripping Designs for the Lunar Surface

    Science.gov (United States)

    Boul, Peter J.; Lange, Kevin E.; Conger, Bruce; Anderson, Molly

    2009-01-01

    Air stripping and distillation are two different gravity-based methods, which may be applied to the purification of wastewater on the lunar base. These gravity-based solutions to water processing are robust physical separation techniques, which may be advantageous to many other techniques for their simplicity in design and operation. The two techniques can be used in conjunction with each other to obtain high purity water. The components and feed compositions for modeling waste water streams are presented in conjunction with the Aspen property system for traditional stage distillation models and air stripping models. While the individual components for each of the waste streams will vary naturally within certain bounds, an analog model for waste water processing is suggested based on typical concentration ranges for these components. Target purity levels for the for recycled water are determined for each individual component based on NASA s required maximum contaminant levels for potable water Distillation processes are modeled separately and in tandem with air stripping to demonstrate the potential effectiveness and utility of these methods in recycling wastewater on the Moon. Optimum parameters such as reflux ratio, feed stage location, and processing rates are determined with respect to the power consumption of the process. Multistage distillation is evaluated for components in wastewater to determine the minimum number of stages necessary for each of 65 components in humidity condensate and urine wastewater mixed streams. Components of the wastewater streams are ranked by Henry s Law Constant and the suitability of air stripping in the purification of wastewater in terms of component removal is evaluated. Scaling factors for distillation and air stripping columns are presented to account for the difference in the lunar gravitation environment. Commercially available distillation and air stripping units which are considered suitable for Exploration Life Support

  15. Validation of Computed Radiography (CR) Exposure Chart for Stainless Steel and Aluminium

    International Nuclear Information System (INIS)

    Nassir, M.A.; Khairul Anuar Mohd Salleh; Arshad Yassin

    2015-01-01

    Computed radiography (CR) is a technique that is currently used to complement the conventional radiography in Non Destructive Testing (NDT). With CR, phosphorous base imaging plate (IP) is used to acquire digital radiographic images. The degree of absorption by the IP is proportional to the intensity of the dose received. The IP stores latent image which subsequently digitized by the CR reader. Prior to radiography exposure, the radiation dosage is determined by referring to the exposure chart. Exposure chart is one of the most important tools for achieving acceptable quality radiographs. Therefore, it is important to have a reliable and accurate exposure chart. The aim of this study is to test and validate exposure charts that were developed based on the statistical analysis of the digital radiographic grey values. The charts produced were for stainless steel and aluminum. According to EN 14784-2:2005, acceptable normalized signal-to-noise ratio (SNR N ) for testing class A and class B shall have minimum 70 and 120 respectively. (author)

  16. Simulation studies for the ATLAS upgrade Strip tracker

    CERN Document Server

    Wang, Jike; The ATLAS collaboration

    2017-01-01

    ATLAS is making extensive efforts towards preparing a detector upgrade for the High luminosity operations of the LHC (HL-LHC), which will commence operation in ~10 years. The current ATLAS Inner Detector will be replaced by a all-silicon tracker (comprising an inner Pixel tracker and outer Strip tracker). The software currently used for the new silicon tracker is broadly inherited from that used for the LHC Run 1 and 2, but many new developments have been made to better fulfil the future detector and operation requirements. One aspect in particular which will be highlighted is the simulation software for the Strip tracker. The available geometry description software (including the detailed description for all the sensitive elements, the services, etc.) did not allow for accurate modeling of the planned detector design. A range of sensors/layouts for the Strip tracker are being considered and must be studied in detailed simulations in order to assess the performance and ascertain that requirements are met. For...

  17. Modi ed strip packing heuristics for the rectangular variable-sized ...

    African Journals Online (AJOL)

    Two packing problems are considered in this paper, namely the well-known strip packing problem (SPP) and the variable-sized bin packing problem (VSBPP). A total of 252 strip packing heuristics (and variations thereof) from the literature, as well as novel heuristics proposed by the authors, are compared statistically by ...

  18. CLOSED-LOOP STRIPPING ANALYSIS (CLSA) OF ...

    Science.gov (United States)

    Synthetic musk compounds have been found in surface water, fish tissues, and human breast milk. Current techniques for separating these compounds from fish tissues require tedious sample clean-upprocedures A simple method for the deterrnination of these compounds in fish tissues has been developed. Closed-loop stripping of saponified fish tissues in a I -L Wheaton purge-and-trap vessel is used to strip compounds with high vapor pressures such as synthetic musks from the matrix onto a solid sorbent (Abselut Nexus). This technique is useful for screening biological tissues that contain lipids for musk compounds. Analytes are desorbed from the sorbent trap sequentially with polar and nonpolar solvents, concentrated, and directly analyzed by high resolution gas chromatography coupled to a mass spectrometer operating in the selected ion monitoring mode. In this paper, we analyzed two homogenized samples of whole fish tissues with spiked synthetic musk compounds using closed-loop stripping analysis (CLSA) and pressurized liquid extraction (PLE). The analytes were not recovered quantitatively but the extraction yield was sufficiently reproducible for at least semi-quantitative purposes (screening). The method was less expensive to implement and required significantly less sample preparation than the PLE technique. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water,

  19. Application of Special Cause Control Charts to Green Sand Process

    Directory of Open Access Journals (Sweden)

    Perzyk M.

    2015-12-01

    Full Text Available Statistical Process Control (SPC based on the well known Shewhart control charts, is widely used in contemporary manufacturing industry, including many foundries. However, the classic SPC methods require that the measured quantities, e.g. process or product parameters, are not auto-correlated, i.e. their current values do not depend on the preceding ones. For the processes which do not obey this assumption the Special Cause Control (SCC charts were proposed, utilizing the residual data obtained from the time-series analysis. In the present paper the results of application of SCC charts to a green sand processing system are presented. The tests, made on real industrial data collected in a big iron foundry, were aimed at the comparison of occurrences of out-of-control signals detected in the original data with those appeared in the residual data. It was found that application of the SCC charts reduces numbers of the signals in almost all cases It is concluded that it can be helpful in avoiding false signals, i.e. resulting from predictable factors.

  20. AMDIS and CHART update. 1

    International Nuclear Information System (INIS)

    Murakami, I.; Kato, T.; Igarashi, A.

    2002-10-01

    A working group for updating atomic and molecular collision data in the NIFS database AMDIS (electron scattering) and CHART (ion scattering) has been organized. This group has searched and reviewed literatures for collecting relevant atomic data with are to be included into the database. This is a summary report of the activities of this working group. (author)

  1. Energy-Efficient Bioalcohol Recovery by Gel Stripping

    Science.gov (United States)

    Godbole, Rutvik; Ma, Lan; Hedden, Ronald

    2014-03-01

    Design of energy-efficient processes for recovering butanol and ethanol from dilute fermentations is a key challenge facing the biofuels industry due to the high energy consumption of traditional multi-stage distillation processes. Gel stripping is an alternative purification process by which a dilute alcohol is stripped from the fermentation product by passing it through a packed bed containing particles of a selectively absorbent polymeric gel material. The gel must be selective for the alcohol, while swelling to a reasonable degree in dilute alcohol-water mixtures. To accelerate materials optimization, a combinatorial approach is taken to screen a matrix of copolymer gels having orthogonal gradients in crosslinker concentration and hydrophilicity. Using a combination of swelling in pure solvents, the selectivity and distribution coefficients of alcohols in the gels can be predicted based upon multi-component extensions of Flory-Rehner theory. Predictions can be validated by measuring swelling in water/alcohol mixtures and conducting h HPLC analysis of the external liquid. 95% + removal of butanol from dilute aqueous solutions has been demonstrated, and a mathematical model of the unsteady-state gel stripping process has been developed. NSF CMMI Award 1335082.

  2. Historical Map & Chart Collection of NOAA's Nautical Charts, Hydrographic Surveys, Topographic Surveys, Geodetic Surveys, City Plans, and Civil War Battle Maps Starting from the mid 1700's

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Historical Map and Chart Collection of the Office of Coast Survey contains over 20000 historical maps and charts from the mid 1700s through the late 1900s. These...

  3. The Energy Chart'93

    International Nuclear Information System (INIS)

    Shervashidze, N.

    1993-01-01

    The Energy Chart'93 is developed with respect to forthcoming restructuring of energy sector in Bulgaria and contains its main directions for both short- and long-term periods. The priorities are given to: energy supply, stabilization of the existing units, ecological development, domestic energy sources, atomic energy, gas energy, utilization of the available hydrological potential. The leading role of legislation in this area is also pointed out, as well as the regulating function of the Committee of Energy. (author)

  4. Understanding Charts and Graphs.

    Science.gov (United States)

    1987-07-28

    Farenheit degrees, which have no Onaturalo zero ); finally, ratio scales have numbers that are ordered so that the magnitudes of differences are important and...system. They have to do with the very nature of how marks serve as meaningful symbols. In the ideal case, a chart or graph will be absolutely unambiguous...and these laws comprise this principle (see Stevens, 1974). Absolute discriminability: A minimal magnitude of a mark is necessary for it to be detected

  5. Electron capture by highly stripped ions

    International Nuclear Information System (INIS)

    Greenland, P.T.

    1981-06-01

    This review describes theories of electron capture suitable for the description of rearrangement collisions between atomic hydrogen and completely stripped projectiles with charge greater than unity. The region of impact velocity considered lies between 0.05 and 3 au, which is of technological importance in fusion power devices. The semiclassical, impact parameter formalism is discussed and the use of atomic expansions at medium impact velocity is described. Experimental results for both completely and partially stripped projectiles are reviewed. The use of a molecular basis at low energy, and the role of pseudocrossings peculiar to the two centre Coulomb interaction are described. Finally, purely classical techniques, in which the electron wavefunction is represented by an ensemble of Kepler orbits are considered. The review was completed in February 1981. (author)

  6. Nuclear reactor spring strip grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Flora, B.S.

    1980-01-01

    An improved and novel grid spacer was developed for use in nuclear reactor fuel assemblies. It is comprised of a series of intersecting support strips and a peripheral support band attached to the ends of the support strips. Each of the openings into which the fuel element is inserted has a number of protruding dimples and springs extending in different directions. The dimples coact with the springs to secure the fuel rods in the openings. Compared with previous designs, this design gives more positive alignment of the support stips while allowing greater flexibility to counterbalance the effects of thermal expansion. The springs are arranged in alternating directions so that the reaction forces tend to counterbalance each other, which in turn minimizes the reaction loads on the supporting structure. (D.N.)

  7. ALICE Silicon Strip Detector

    CERN Multimedia

    Nooren, G

    2013-01-01

    The Silicon Strip Detector (SSD) constitutes the two outermost layers of the Inner Tracking System (ITS) of the ALICE Experiment. The SSD plays a crucial role in the tracking of the particles produced in the collisions connecting the tracks from the external detectors (Time Projection Chamber) to the ITS. The SSD also contributes to the particle identification through the measurement of their energy loss.

  8. Distribution of electric field and charge collection in silicon strip detectors

    International Nuclear Information System (INIS)

    Anokhin, I.E.; Zinets, O.S.

    1995-01-01

    The distribution of electric field in silicon strip detectors is analyzed in the case of dull depletion as well as for partial depletion. Influence of inhomogeneous electric fields on the charge collection and performances of silicon strip detectors is discussed

  9. Quality assurance in a radiation oncology unit: the chart round experience

    International Nuclear Information System (INIS)

    Fogarty, G.B.; Peters, L.J.; Hornby, C.; Ferguson, H.M.

    2001-01-01

    Quality assurance ensures that planned treatments eventuate. Programmes must include feedback loops to promptly correct any shortfall in predetermined standards. In March 1999, a weekly Chart Round was introduced to verify that certain items relevant to quality care were being completed for patients of the Head and Neck Radiotherapy Unit at the Peter MacCallum Cancer Institute. The experience was reviewed after 1 year and it was found that the initiation of Chart Rounds has assisted in raising the level of item completion from 80% to 99% in similar groups of patients treated before and after the initiation of the Chart Round. Initiation of the Chart Round has also provided a useful forum for in-house peer-review, education and effective real-time communication between medical and allied health personnel, all of which has further added to the quality of patient care. Copyright (2001) Blackwell Science Pty Ltd

  10. Chart Supplements - Aeronautical Information Services Digital Products

    Data.gov (United States)

    Department of Transportation — The Chart Supplements are searchable by individual airport in PDF format. They contain data on public and joint use airports, seaplane bases, heliports, VFR airport...

  11. Design chart of optimum current leads

    International Nuclear Information System (INIS)

    Ishibashi, K.; Katase, A.; Maechata, K.

    1986-01-01

    The heat flow through current leads is one of major heat losses in a superconducting magnet system. To reduce the heat flow, current leads have been optimized in a complex way by varying such quantities as conductor length, cross-sectional area, heat transfer coefficient and cooling perimeter. Therefore, this study is made to simplify the design procedure, and to explain the general characteristics of the current leads. A new combined parameter which takes turbulent flow into account is introduced in the present work to enable us to draw a useful design chart. This chart gives, to a wide variety of current leads, detailed information about the optimum design-viz. geometric dimensions, heat flow into liquid helium, and pressure drop of the cooling gas. Change of the cross-sectional area along the conductor may improve the current lead performance. The effects of this area change are examined in detail

  12. Prevalence of overweight in children and adolescents with attention deficit hyperactivity disorder and autism spectrum disorders: a chart review

    Directory of Open Access Journals (Sweden)

    Tybor David J

    2005-12-01

    Full Text Available Abstract Background The condition of obesity has become a significant public health problem in the United States. In children and adolescents, the prevalence of overweight has tripled in the last 20 years, with approximately 16.0% of children ages 6–19, and 10.3% of 2–5 year olds being considered overweight. Considerable research is underway to understand obesity in the general pediatric population, however little research is available on the prevalence of obesity in children with developmental disorders. The purpose of our study was to determine the prevalence of overweight among a clinical population of children diagnosed with attention deficit hyperactivity disorder (ADHD and autism spectrum disorders (ASD. Methods Retrospective chart review of 140 charts of children ages 3–18 years seen between 1992 and 2003 at a tertiary care clinic that specializes in the evaluation and treatment of children with developmental, behavioral, and cognitive disorders. Diagnostic, medical, and demographic information was extracted from the charts. Primary diagnoses of either ADHD or ASD were recorded, as was information on race/ethnicity, age, gender, height, and weight. Information was also collected on medications that the child was taking. Body mass index (BMI was calculated from measures of height and weight recorded in the child's chart. The Center for Disease Control's BMI growth reference was used to determine an age- and gender-specific BMI z-score for the children. Results The prevalence of at-risk-for-overweight (BMI >85th%ile and overweight (BMI > 95th%ile was 29% and 17.3% respectively in children with ADHD. Although the prevalence appeared highest in the 2–5 year old group (42.9%ile, differences among age groups were not statistically significant. Prevalence did not differ between boys and girls or across age groups (all p > 0.05. For children with ASD, the overall prevalence of at-risk-for-overweight was 35.7% and prevalence of overweight

  13. Advancements of floating strip Micromegas detectors for medical imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Klitzner, Felix; Biebel, Otmar; Bortfeldt, Jonathan; Flierl, Bernhard [LS Schaile, LMU Muenchen (Germany); Magallanes, Lorena [LS Parodi, LMU Muenchen (Germany); Universitaetsklinikum Heidelberg (Germany); Parodi, Katia [LS Parodi, LMU Muenchen (Germany); Heidelberger Ionenstrahl Therapiezentrum (Germany); Voss, Bernd [Gesellschaft fuer Schwerionenforschung, Darmstadt (Germany)

    2016-07-01

    Floating strip Micromegas have proven to be high-rate capable tracking detectors with excellent spatial and temporal resolution for particle fluxes up to 7 MHz/cm{sup 2}. To further increase the high-rate capability a Ne:CF{sub 4} 86:14 vol.% gas mixture has been used as detector gas. We present results from measurements with a seven detector system consisting of six low material budget floating strip Micromegas, a GEM detector and a scintillator based particle range telescope. The gaseous and the scintillation detectors were read out with APV25 frontend boards, allowing for single strip readout with pulse height and timing information. A two-dimensional readout anode for floating strip Micromegas has been tested for the first time. The Micromegas detectors were operated with minimal additional drift field, which significantly improves the timing resolution and also the spatial resolution for inclined tracks. We discuss the detector performance in high-rate carbon and proton beams at the Heidelberg Ion Beam Therapy Center (HIT) and present radiographies of phantoms, acquired with the system.

  14. MUST: A silicon strip detector array for radioactive beam experiments

    CERN Document Server

    Blumenfeld, Y; Sauvestre, J E; Maréchal, F; Ottini, S; Alamanos, N; Barbier, A; Beaumel, D; Bonnereau, B; Charlet, D; Clavelin, J F; Courtat, P; Delbourgo-Salvador, P; Douet, R; Engrand, M; Ethvignot, T; Gillibert, A; Khan, E; Lapoux, V; Lagoyannis, A; Lavergne, L; Lebon, S; Lelong, P; Lesage, A; Le Ven, V; Lhenry, I; Martin, J M; Musumarra, A; Pita, S; Petizon, L; Pollacco, E; Pouthas, J; Richard, A; Rougier, D; Santonocito, D; Scarpaci, J A; Sida, J L; Soulet, C; Stutzmann, J S; Suomijärvi, T; Szmigiel, M; Volkov, P; Voltolini, G

    1999-01-01

    A new and innovative array, MUST, based on silicon strip technology and dedicated to the study of reactions induced by radioactive beams on light particles is described. The detector consists of 8 silicon strip - Si(Li) telescopes used to identify recoiling light charged particles through time of flight, energy loss and energy measurements and to determine precisely their scattering angle through X, Y position measurements. Each 60x60 mm sup 2 double sided silicon strip detector with 60 vertical and 60 horizontal strips yields an X-Y position resolution of 1 mm, an energy resolution of 50 keV, a time resolution of around 1 ns and a 500 keV energy threshold for protons. The backing Si(Li) detectors stop protons up to 25 MeV with a resolution of approximately 50 keV. CsI crystals read out by photo-diodes which stop protons up to 70 MeV are added to the telescopes for applications where higher energy particles need to be detected. The dedicated electronics in VXIbus standard allow us to house the 968 logic and a...

  15. The design and application of comprehensive interventional surgery record:evaluation of its usefulness

    International Nuclear Information System (INIS)

    Li Xue; Chen Jinhua; Li Jun

    2010-01-01

    Objective: To design a comprehensive interventional surgery record form in order to standardize and simplify interventional work process and to increase the operative safety. Methods: A comprehensive interventional surgery record form was designed by the authors, which was suitable for making necessary record of different kinds of interventional procedures, for counting operation time, X-ray exposure time and for recording the dose, velocity and injection pressure of the contrast agent used in interventional procedure. The record form made a close combination of the nursing notes with the technological information and focused on compiling the clinical key points. The record form included independent parts for taking the preoperative, in-operative and postoperative facts and evaluations. The corresponding items after employing this record form were compared with that before using this form. The usefulness of the form was evaluated. Results: The use of comprehensive interventional surgery record form overcame the limitations of previously used interventional record chart. The previous record chart paid attention only to the vital signs and operative process, while the newly designed form emphasized the scientific management, which would make the therapeutic procedure to be more standard and the control of X-ray dose and contrast media dosage to be more strict, providing powerful data for scientific administration. After using the comprehensive interventional surgery record form both the nurses' and technicians' comprehensive abilities were improved markedly. Conclusion: The specific and comprehensive interventional record form designed by the authors fully meets the requirements of various interventional procedures, reflecting the particular needs for medical record. The use of this record form can standardize the administration of clinical interventional work. (authors)

  16. Continuous hyperfractionated accelerated radiotherapy (chart) in localized cancer of the esophagus

    International Nuclear Information System (INIS)

    Powell, Melanie E.B.; Hoskin, Peter J.; Saunders, Michele I.; Foy, Christopher J.W.; Dische, Stanley

    1997-01-01

    Purpose: To assess the efficacy and toxicity of continuous hyperfractionated accelerated radiotherapy (CHART) in locoregional control compared with a historical group of patients treated with conventionally fractionated radical radiotherapy. Methods and Materials: Between 1985 and 1994, 54 patients with localized esophageal cancer were treated with CHART. Twenty-eight patients received CHART alone (54 Gy in 36 fractions over 12 consecutive days) and 15 were given intravenous mitomycin C and cisplatin on days 10 and 13, respectively. Eleven patients received 40.5 Gy in 27 fractions over 9 days, followed by a single high-dose-rate intraluminal brachytherapy insertion of 15 Gy at 1 cm. Results: Acute toxicity was well tolerated and dysphagia was improved in 35 patients (65%), with 28 (52%) eating a normal diet by week 12. This compares with an improvement in dysphagia score in 72% of the conventionally treated group. The median duration of relief of dysphagia was 7.8 months (range 0-41.4) in the CHART group compared with 5.5 months (range 0-48) in the controls. Strictures developed in 29 patients (61%) and 18 were confirmed on biopsy to be due to recurrent disease. Median survival was 12 months (range 0.5-112) in the CHART group and 15 months (range 3.6-56) in the control patients. Conclusion: CHART is well tolerated and achieves a high rate of local control. Palliation in the short overall treatment time of esophageal cancer is an advantage in these patients whose median survival is only 12 months

  17. Ethical and legal questions as regards filling out dental clinical charts

    Directory of Open Access Journals (Sweden)

    Mauro Henrique Nogueira Guimarãe de Abreu

    Full Text Available Objective: Evaluate imperfections in filling out dental clinical history charts of patients attended at the “Universidade Estadual de Montes Claros – Unimontes”, in 2005, from the ethical and legal aspects. Method: Descriptive statistical analysis, Pearson’s correlation, Chi-Square test (p<0.05 with Bonferroni correction in a contingency table (p<0.003 tests were performed, and Anova – Tukey (p<0.05 were calculate using SPSS software. This study was conducted using 881 clinical history charts of 19 subjects. Results: The highest percentage of charts concerned Stomatology (12% and 8 th period of the course (25%. The majority (63.3% of chartshad fields left blank and in 68% the handwriting was illegible. Unjustifiable erasures were found in 74.7% of charts. The majority of charts (98% were filled out in ink. The treatment plan was signed by course tutor in 83% of the cases. The term of consent was signed in the 94.9 % of the charts. As regards mistakes, 5.1% of documents had one error; 42% two errors; 23.5% three or more errors (average 1.89(± 0.9; percentile 25%=1; 50%=2 and 75%=2. The difference in the proportion of errors as regards filling out all fields differed statistically among the periods (p<0.05. Conclusion: It was concluded that an alarming number of documents were filled out incorrectly. The worst filling out performance was shown in the 5th, 6th and 7th periods (p<0.05.

  18. Evaluation of FOXFET biased ac-coupled silicon strip detector prototypes for CDF SVX upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Laakso, M. (Fermi National Accelerator Lab., Batavia, IL (United States) Research Inst. for High Energy Physics (SEFT), Helsinki (Finland))

    1992-03-01

    Silicon microstrip detectors for high-precision charged particle position measurements have been used in nuclear and particle physics for years. The detectors have evolved from simple surface barrier strip detectors with metal strips to highly complicated double-sided AC-coupled junction detectors. The feature of AC-coupling the readout electrodes from the diode strips necessitates the manufacture of a separate biasing structure for the strips, which comprises a common bias line together with a means for preventing the signal from one strip from spreading to its neighbors through the bias line. The obvious solution to this is to bias the strips through individual high value resistors. These resistors can be integrated on the detector wafer by depositing a layer of resistive polycrystalline silicon and patterning it to form the individual resistors. To circumvent the extra processing step required for polysilicon resistor processing and the rather difficult tuning of the process to obtain uniform and high enough resistance values throughout the large detector area, alternative methods for strip biasing have been devised. These include the usage of electron accumulation layer resistance for N{sup +}{minus} strips or the usage of the phenomenon known as the punch-through effect for P{sup +}{minus} strips. In this paper we present measurement results about the operation and radiation resistance of detectors with a punch-through effect based biasing structure known as a Field OXide Field-Effect Transistor (FOXFET), and present a model describing the FOXFET behavior. The studied detectors were prototypes for detectors to be used in the CDF silicon vertex detector upgrade.

  19. Evaluation of FOXFET biased ac-coupled silicon strip detector prototypes for CDF SVX upgrade

    International Nuclear Information System (INIS)

    Laakso, M.

    1992-03-01

    Silicon microstrip detectors for high-precision charged particle position measurements have been used in nuclear and particle physics for years. The detectors have evolved from simple surface barrier strip detectors with metal strips to highly complicated double-sided AC-coupled junction detectors. The feature of AC-coupling the readout electrodes from the diode strips necessitates the manufacture of a separate biasing structure for the strips, which comprises a common bias line together with a means for preventing the signal from one strip from spreading to its neighbors through the bias line. The obvious solution to this is to bias the strips through individual high value resistors. These resistors can be integrated on the detector wafer by depositing a layer of resistive polycrystalline silicon and patterning it to form the individual resistors. To circumvent the extra processing step required for polysilicon resistor processing and the rather difficult tuning of the process to obtain uniform and high enough resistance values throughout the large detector area, alternative methods for strip biasing have been devised. These include the usage of electron accumulation layer resistance for N + - strips or the usage of the phenomenon known as the punch-through effect for P + - strips. In this paper we present measurement results about the operation and radiation resistance of detectors with a punch-through effect based biasing structure known as a Field OXide Field-Effect Transistor (FOXFET), and present a model describing the FOXFET behavior. The studied detectors were prototypes for detectors to be used in the CDF silicon vertex detector upgrade

  20. Planar Poincare chart - A planar graphic representation of the state of light polarization

    Science.gov (United States)

    Tedjojuwono, Ken K.; Hunter, William W., Jr.; Ocheltree, Stewart L.

    1989-01-01

    The planar Poincare chart, which represents the complete planar equivalence of the Poincare sphere, is proposed. The four sets of basic lines are drawn on two separate charts for the generalization and convenience of reading the scale. The chart indicates the rotation of the principal axes of linear birefringent material. The relationships between parameters of the two charts are given as 2xi-2phi (orientation angle of the major axis-ellipticity angle) pair and 2alpha-delta (angle of amplitude ratio-phase difference angle) pair. The results are useful for designing and analyzing polarization properties of optical components with birefringent properties.

  1. Study of the technics of coating stripping and FBG writing on polyimide fiber

    Science.gov (United States)

    Song, ZhiQiang; Qi, HaiFeng; Ni, JiaSheng; Wang, Chang

    2017-10-01

    Compared with ordinary optical fiber, polyimide fiber has the characteristics of high temperature resistance and high strength, which has important application in the field of optical fiber sensing. The common methods of polyimide coating stripping were introduced in this paper, including high temperature stripping, chemical stripping and arc ablation. In order to meet the requirements of FBG writing technology, a method using argon ion laser ablation coating was proposed. The method can precisely control the stripping length of the coating and completely does not affect the tensile strength of the optical fiber. According to the experiment, the fabrication process of polyimide FBG is stripping-hydrogen loadingwriting. Under the same conditions, 10 FBG samples were fabricated with good uniformity of wavelength bandwidth and reflectivity. UV laser ablation of polyimide coating has been proved to be a safe, reliable and efficient method.

  2. HST IMAGING OF DUST STRUCTURES AND STARS IN THE RAM PRESSURE STRIPPED VIRGO SPIRALS NGC 4402 AND NGC 4522: STRIPPED FROM THE OUTSIDE IN WITH DENSE CLOUD DECOUPLING

    International Nuclear Information System (INIS)

    Abramson, A.; Kenney, J.; Crowl, H.; Tal, T.

    2016-01-01

    We describe and constrain the origins of interstellar medium (ISM) structures likely created by ongoing intracluster medium (ICM) ram pressure stripping in two Virgo Cluster spirals, NGC 4522 and NGC 4402, using Hubble Space Telescope (HST) BVI images of dust extinction and stars, as well as supplementary H i, H α , and radio continuum images. With a spatial resolution of ∼10 pc in the HST images, this is the highest-resolution study to date of the physical processes that occur during an ICM–ISM ram pressure stripping interaction, ram pressure stripping's effects on the multi-phase, multi-density ISM, and the formation and evolution of ram-pressure-stripped tails. In dust extinction, we view the leading side of NGC 4402 and the trailing side of NGC 4522, and so we see distinct types of features in both. In both galaxies, we identify some regions where dense clouds are decoupling or have decoupled and others where it appears that kiloparsec-sized sections of the ISM are moving coherently. NGC 4522 has experienced stronger, more recent pressure and has the “jellyfish” morphology characteristic of some ram-pressure-stripped galaxies. Its stripped tail extends up from the disk plane in continuous upturns of dust and stars curving up to ∼2 kpc above the disk plane. On the other side of the galaxy, there is a kinematically and morphologically distinct extraplanar arm of young, blue stars and ISM above a mostly stripped portion of the disk, and between it and the disk plane are decoupled dust clouds that have not been completely stripped. The leading side of NGC 4402 contains two kiloparsec-scale linear dust filaments with complex substructure that have partially decoupled from the surrounding ISM. NGC 4402 also contains long dust ridges, suggesting that large parts of the ISM are being pushed out at once. Both galaxies contain long ridges of polarized radio continuum emission indicating the presence of large-scale, ordered magnetic fields. We propose that

  3. Designing business charts with Excel based on the standards of HICHERT SUCCESS

    CERN Document Server

    Gerths, Holger

    2014-01-01

    This e-book offers a comprehensive range of knowledge for creating professional business charts based on the concept of HICHERT®SUCCESS. Given this knowledge, the SUCCESS rules of designing good business charts can be followed easily. This training is based on one complex example. The tips and trick learned can be transferred to other Excel chart types easily. Contents: Introduction to the HICHERT®SUCCESS design rules.Tips and tricks for Excel 2003 and 2007/2010.Comprehensive trai

  4. The bacterial contamination rate of glucose meter test strips in the hospital setting

    Science.gov (United States)

    Al-Rubeaan, Khalid A.; Saeb, Amr T. M.; AlNaqeb, Dhekra M.; AlQumaidi, Hamed M.; AlMogbel, Turki A.

    2016-01-01

    Objectives: To assess the rate of bacterial contamination of the multi-use vial and single-use packed glucose meter strips, and to identify the type and frequency of various bacterial contamination in different hospital wards. Methods: This prospective observational study was conducted by a team from the Strategic Center for Diabetes Research in 7 general hospitals in the Central region of Saudi Arabia during the period from August to September 2014 to assess the bacterial contamination rate of the unused strips. A total of 10,447 strips were cultured using proper agar media and incubated both aerobically and anaerobically. Results: The total bacterial contamination rate for the multi-use vials glucose strips was 31.7%, while single-use packed strips were not contaminated at all. Ministry of Health hospitals had the highest contamination rates compared with other hospitals. Critical, obstetric, and surgical wards had the highest bacterial isolates number, where most were in the risk group 3 according to the National Institute of Health guidelines. Staphylococcus species were the most common bacteria found. Conclusion: Glucose meter strips should be recognized as a source of bacterial contamination that could be behind serious hospital acquired infections. The hospital infection control team should adopt proper measures to implement protocols for glucose meter cleaning and glucose strips handling. PMID:27570855

  5. Choosing order of operations to accelerate strip structure analysis in parameter range

    Science.gov (United States)

    Kuksenko, S. P.; Akhunov, R. R.; Gazizov, T. R.

    2018-05-01

    The paper considers the issue of using iteration methods in solving the sequence of linear algebraic systems obtained in quasistatic analysis of strip structures with the method of moments. Using the analysis of 4 strip structures, the authors have proved that additional acceleration (up to 2.21 times) of the iterative process can be obtained during the process of solving linear systems repeatedly by means of choosing a proper order of operations and a preconditioner. The obtained results can be used to accelerate the process of computer-aided design of various strip structures. The choice of the order of operations to accelerate the process is quite simple, universal and could be used not only for strip structure analysis but also for a wide range of computational problems.

  6. A robust standard deviation control chart

    NARCIS (Netherlands)

    Schoonhoven, M.; Does, R.J.M.M.

    2012-01-01

    This article studies the robustness of Phase I estimators for the standard deviation control chart. A Phase I estimator should be efficient in the absence of contaminations and resistant to disturbances. Most of the robust estimators proposed in the literature are robust against either diffuse

  7. Nuclear industry chart no. 20 - Sweden

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    A folding chart is presented of the Swedish nuclear industry, which shows the government bodies, companies, utilities and other groups who participate in the nuclear field. Their special interests and activities and affiliations with each other and with international organisations are indicated. (U.K.)

  8. ICS International Chronostratigraphic Chart 2016/04

    NARCIS (Netherlands)

    Cohen, K.M.|info:eu-repo/dai/nl/185633374; Finney, S.C.; Gibbard, P.L.

    Units of all ranks are in the process of being defined by Global Boundary Stratotype Section and Points (GSSP) for their lowerboundaries, including those of the Archean and Proterozoic, long defined by Global Standard Stratigraphic Ages (GSSA). Charts and detailed information on ratified GSSPs are

  9. ICS International Chronostratigraphic Chart 2017/02

    NARCIS (Netherlands)

    Cohen, K.M.|info:eu-repo/dai/nl/185633374; Harper, D.A.T.; Gibbard, P.L.

    Units of all ranks are in the process of being defined by Global Boundary Stratotype Section and Points (GSSP) for their lowerboundaries, including those of the Archean and Proterozoic, long defined by Global Standard Stratigraphic Ages (GSSA). Charts and detailed information on ratified GSSPs are

  10. Flaw evaluation charts

    International Nuclear Information System (INIS)

    Korosec, D.; Vojvodic Tuma, J.

    1999-01-01

    The structural integrity of the primary components in pressurized water reactor nuclear power plant is very important in the respect of safe and efficient operation. These components have to be subjected to periodic controls. In the light of fracture mechanics concept, the acceptance criteria for defects (flaws) are developed. Flaw evaluation procedure is necessary, to evaluate the defects regarding their acceptability for further operation. The objective of the flaw evaluation charts is to provide a series of simple graphs as decision maps. that immediate decision may be taken regarding the acceptability of a detected defects, on the basis of ASME Code XI criteria.(author)

  11. On the Use of Ashenhurst Decomposition Chart as an Alternative to ...

    African Journals Online (AJOL)

    ... the Ashenhurst decomposition chart is shown to be a mapping technique which solves this selection problem and enables the design of logic circuits with desirable attributes using multiplexers. The Ashenhurst decomposition chart also serves as a bridging technique between the map based and algorithmic based digital ...

  12. Strip-Bark Morphology and Radial Growth Trends in Ancient Pinus sibirica Trees From Central Mongolia

    Science.gov (United States)

    Leland, Caroline; Cook, Edward R.; Andreu-Hayles, Laia; Pederson, Neil; Hessl, Amy; Anchukaitis, Kevin J.; Byambasuren, Oyunsanaa; Nachin, Baatarbileg; Davi, Nicole; D'Arrigo, Rosanne; Griffin, Kevin; Bishop, Daniel A.; Rao, Mukund Palat

    2018-03-01

    Some of the oldest and most important trees used for dendroclimatic reconstructions develop strip-bark morphology, in which only a portion of the stem contains living tissue. Yet the ecophysiological factors initiating strip bark and the potential effect of cambial dieback on annual ring widths and tree-ring estimates of past climate remain poorly understood. Using a combination of field observations and tree-ring data, we investigate the causes and timing of cambial dieback events in Pinus sibirica strip-bark trees from central Mongolia and compare the radial growth rates and trends of strip-bark and whole-bark trees over the past 515 years. Results indicate that strip bark is more common on the southern aspect of trees, and dieback events were most prevalent in the 19th century, a cold and dry period. Further, strip-bark and whole-bark trees have differing centennial trends, with strip-bark trees exhibiting notably large increases in ring widths at the beginning of the 20th century. We find a steeper positive trend in the strip-bark chronology relative to the whole-bark chronology when standardizing with age-dependent splines. We hypothesize that localized warming on the southern side of stems due to solar irradiance results in physiological damage and dieback and leads to increasing tree-ring increment along the living portion of strip-bark trees. Because the impact of cambial dieback on ring widths likely varies depending on species and site, we suggest conducting a comparison of strip-bark and whole-bark ring widths before statistically treating ring-width data for climate reconstructions.

  13. Record annual increase of carbon dioxide observed at Mauna Loa for 2015 |

    Science.gov (United States)

    Climate Oceans & Coasts Fisheries Satellites Research Marine & Aviation Charting Sanctuaries Research Record annual increase of carbon dioxide observed at Mauna Loa for 2015 Climate Research Share Niño weather pattern, as forests, plantlife and other terrestrial systems responded to changes in

  14. Continuous liquid sheet generator for ion stripping

    International Nuclear Information System (INIS)

    Gavin, B.; Batson, P.; Leemann, B.; Rude, B.

    1984-10-01

    Many of the technical problems of generating a large thin liquid sheet from 0.02 to 0.20 μm thick (3 to 40 μgm/cm 2 ) have been solved. It is shown that this perennial sheet is stable and consonant in dimension. Several ion beam species from the SuperHILAC have been used for evaluation; at 0.11 MeV/n. In one of three modes this sheet serves as an equivalent substitute for a carbon foil. The second mode is characterized by a solid-like charge state distribution but with a varying fraction of unstripped ions. The third mode gives stripping performance akin to a vapor stripping medium. 9 references, 7 figures

  15. 7 CFR 51.2276 - Color chart.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... Walnut Color Chart) to which reference is made in §§ 51.2281 and 51.2282 illustrates the four shades of...

  16. ICS International Chronostratigraphic Chart 2015/01

    NARCIS (Netherlands)

    Cohen, K.M.|info:eu-repo/dai/nl/185633374; Finney, S.C.; Gibbard, P.L.

    Units of all ranks are in the process of being defined by Global Boundary Stratotype Section and Points (GSSP) for their lower boundaries, including those of the Archean and Proterozoic, long defined by Global Standard Stratigraphic Ages (GSSA). Charts and detailed information on ratified GSSPs are

  17. Cascade air stripping: Techno-economic evaluation of a new ground water treatment process

    International Nuclear Information System (INIS)

    Nirmalakhandan, N.; Peace, G.L.; Shanbhag, A.R.; Speece, R.E.

    1992-01-01

    A simple modification of the conventional air-stripping process introduced as cascade air stripping is proposed for efficient and economical removal of semivolatile and low volatility contaminants from ground water. The technical feasibility and economic viability of this process are evaluated using field test results and cost model simulations. The field tests enabled the process model to be verified at various water flow rates ranging from 150 gpm to 400 gpm. The field study also demonstrated the feasibility of the proposed system at a near full-scale level. Cost models were used to compare the proposed process to conventional air stripping and granular-activated carbon adsorption in removing a range of contaminants. This analysis showed that the treatment cost (cents/1,000 gal) of cascade air stripping is about 15% lower than conventional air stripping and about 40% lower than granular-activated carbon adsorption

  18. MO-A-BRB-03: Integration Issues in Electronic Charting for External Beam Therapy

    International Nuclear Information System (INIS)

    Sutlief, S.

    2015-01-01

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy

  19. Growth charts of human development.

    Science.gov (United States)

    van Buuren, Stef

    2014-08-01

    This article reviews and compares two types of growth charts for tracking human development over age. Both charts assume the existence of a continuous latent variable, but relate to the observed data in different ways. The D-score diagram summarizes developmental indicators into a single aggregate score measuring global development. The relations between the indicators should be consistent with the Rasch model. If true, the D-score is a measure with interval scale properties, and allows for the calculation of meaningful differences both within and across age. The stage line diagram describes the natural development of ordinal indicators. The method models the transition probabilities between successive stages of the indicator as smoothly varying functions of age. The location of each stage is quantified by the mid-P-value. Both types of diagrams assist in identifying early and delayed development, as well as finding differences in tempo. The relevant techniques are illustrated to track global development during infancy and early childhood (0-2 years) and Tanner pubertal stages (8-21 years). New reference values for both applications are provided. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Air Stripping Designs and Reactive Water Purification Processes for the Lunar Surface

    Science.gov (United States)

    Boul, Peter J.; Lange, Kevin; Conger, Bruce; Anderson, Molly

    2010-01-01

    Air stripping designs are considered to reduce the presence of volatile organic compounds in the purified water. Components of the wastewater streams are ranked by Henry's Law Constant and the suitability of air stripping in the purification of wastewater in terms of component removal is evaluated. Distillation processes are modeled in tandem with air stripping to demonstrate the potential effectiveness and utility of these methods in recycling wastewater on the Moon. Scaling factors for distillation and air stripping columns are presented to account for the difference in the lunar gravitation environment. Commercially available distillation and air stripping units which are considered suitable for Exploration Life Support are presented. The advantages to the various designs are summarized with respect to water purity levels, power consumption, and processing rates. An evaluation of reactive distillation and air stripping is presented with regards to the reduction of volatile organic compounds in the contaminated water and air. Among the methods presented, an architecture is presented for the evaluation of the simultaneous oxidation of organics in air and water. These and other designs are presented in light of potential improvements in power consumptions and air and water purities for architectures which include catalytic activity integrated into the water processor. In particular, catalytic oxidation of organics may be useful as a tool to remove contaminants that more traditional distillation and/or air stripping columns may not remove. A review of the current leading edge at the commercial level and at the research frontier in catalytically active materials is presented. Themes and directions from the engineering developments in catalyst design are presented conceptually in light of developments in the nanoscale chemistry of a variety of catalyst materials.